from unittest.mock import Mock, patch
import pytest
from akkudoktoreos.devices.inverter import Inverter, InverterParameters
@pytest.fixture
def mock_battery() -> Mock:
mock_battery = Mock()
2024-12-19 14:50:19 +01:00
mock_battery.charge_energy = Mock(return_value=(0.0, 0.0))
mock_battery.discharge_energy = Mock(return_value=(0.0, 0.0))
mock_battery.device_id = "battery1"
return mock_battery
@pytest.fixture
def inverter(mock_battery, devices_eos) -> Inverter:
devices_eos.add_device(mock_battery)
mock_self_consumption_predictor = Mock()
mock_self_consumption_predictor.calculate_self_consumption.return_value = 1.0
with patch(
"akkudoktoreos.devices.inverter.get_eos_load_interpolator",
return_value=mock_self_consumption_predictor,
):
iv = Inverter(
InverterParameters(
device_id="iv1", max_power_wh=500.0, battery_id=mock_battery.device_id
),
)
devices_eos.add_device(iv)
devices_eos.post_setup()
return iv
def test_process_energy_excess_generation(inverter, mock_battery):
# Battery charges 100 Wh with 10 Wh loss
mock_battery.charge_energy.return_value = (100.0, 10.0)
generation = 600.0
consumption = 200.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == pytest.approx(290.0, rel=1e-2) # 290 Wh feed-in after battery charges
assert grid_import == 0.0 # No grid draw
assert losses == 10.0 # Battery charging losses
assert self_consumption == 200.0 # All consumption is met
mock_battery.charge_energy.assert_called_once_with(400.0, hour)
mock_battery.discharge_energy.assert_not_called()
inverter.self_consumption_predictor.calculate_self_consumption.assert_called_once_with(
consumption, generation
)
def test_process_energy_excess_generation_interpolator(inverter, mock_battery):
# Battery charges 100 Wh with 10 Wh loss
mock_battery.charge_energy.return_value = (100.0, 10.0)
mock_battery.discharge_energy.return_value = (20.0, 2.0)
inverter.self_consumption_predictor.calculate_self_consumption.return_value = 0.95
generation = 600.0
consumption = 200.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == pytest.approx(
270.0, rel=1e-2
) # 290 Wh feed-in - 5% of generation-consumption self consumption after battery charges
assert grid_import == pytest.approx(0.0, rel=1e-2) # No grid draw
assert losses == 12.0 # Battery charging losses
assert self_consumption == 220.0 # All consumption is met
mock_battery.charge_energy.assert_called_once_with(pytest.approx(380.0, rel=1e-2), hour)
mock_battery.discharge_energy.assert_called_once_with(pytest.approx(20.0, rel=1e-2), hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_called_once_with(
consumption, generation
)
def test_process_energy_generation_equals_consumption(inverter, mock_battery):
generation = 300.0
consumption = 300.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in as generation equals consumption
assert grid_import == 0.0 # No grid draw
assert losses == 0.0 # No losses
assert self_consumption == 300.0 # All consumption is met with generation
mock_battery.charge_energy.assert_not_called()
mock_battery.discharge_energy.assert_not_called()
inverter.self_consumption_predictor.calculate_self_consumption.assert_called_once_with(
consumption, generation
)
def test_process_energy_battery_discharges(inverter, mock_battery):
# Battery discharges 100 Wh with 10 Wh loss already accounted for in the discharge
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (100.0, 10.0)
generation = 100.0
consumption = 250.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in as generation is insufficient
assert grid_import == pytest.approx(
50.0, rel=1e-2
) # Grid supplies remaining shortfall after battery discharge
assert losses == 10.0 # Discharge losses
assert self_consumption == 200.0 # Generation + battery discharge
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(150.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_battery_empty(inverter, mock_battery):
# Battery is empty, so no energy can be discharged
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (0.0, 0.0)
generation = 100.0
consumption = 300.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in as generation is insufficient
assert grid_import == pytest.approx(200.0, rel=1e-2) # Grid has to cover the full shortfall
assert losses == 0.0 # No losses as the battery didn't discharge
assert self_consumption == 100.0 # Only generation is consumed
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(200.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_battery_full_at_start(inverter, mock_battery):
# Battery is full, so no charging happens
2024-12-19 14:50:19 +01:00
mock_battery.charge_energy.return_value = (0.0, 0.0)
generation = 500.0
consumption = 200.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == pytest.approx(
300.0, rel=1e-2
) # All excess energy should be fed into the grid
assert grid_import == 0.0 # No grid draw
assert losses == 0.0 # No losses
assert self_consumption == 200.0 # Only consumption is met
mock_battery.charge_energy.assert_called_once_with(300.0, hour)
mock_battery.discharge_energy.assert_not_called()
inverter.self_consumption_predictor.calculate_self_consumption.assert_called_once_with(
consumption, generation
)
def test_process_energy_insufficient_generation_no_battery(inverter, mock_battery):
# Insufficient generation and no battery discharge
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (0.0, 0.0)
generation = 100.0
consumption = 500.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in as generation is insufficient
assert grid_import == pytest.approx(400.0, rel=1e-2) # Grid supplies the shortfall
assert losses == 0.0 # No losses
assert self_consumption == 100.0 # Only generation is consumed
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(400.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_insufficient_generation_battery_assists(inverter, mock_battery):
# Battery assists with some discharge to cover the shortfall
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (
50.0,
5.0,
) # Battery discharges 50 Wh with 5 Wh loss
generation = 200.0
consumption = 400.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in as generation is insufficient
assert grid_import == pytest.approx(
150.0, rel=1e-2
) # Grid supplies the remaining shortfall after battery discharge
assert losses == 5.0 # Discharge losses
assert self_consumption == 250.0 # Generation + battery discharge
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(200.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_zero_generation(inverter, mock_battery):
# Zero generation, full reliance on battery and grid
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (
100.0,
5.0,
) # Battery discharges 100 Wh with 5 Wh loss
generation = 0.0
consumption = 300.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in as there is zero generation
assert grid_import == pytest.approx(200.0, rel=1e-2) # Grid supplies the remaining shortfall
assert losses == 5.0 # Discharge losses
assert self_consumption == 100.0 # Only battery discharge is consumed
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(300.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_zero_consumption(inverter, mock_battery):
# Generation exceeds consumption, but consumption is zero
2024-12-19 14:50:19 +01:00
mock_battery.charge_energy.return_value = (100.0, 10.0)
generation = 500.0
consumption = 0.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == pytest.approx(390.0, rel=1e-2) # Excess energy after battery charges
assert grid_import == 0.0 # No grid draw as no consumption
assert losses == 10.0 # Charging losses
assert self_consumption == 0.0 # Zero consumption
mock_battery.charge_energy.assert_called_once_with(500.0, hour)
mock_battery.discharge_energy.assert_not_called()
inverter.self_consumption_predictor.calculate_self_consumption.assert_called_once_with(
consumption, generation
)
def test_process_energy_zero_generation_zero_consumption(inverter, mock_battery):
generation = 0.0
consumption = 0.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in
assert grid_import == 0.0 # No grid draw
assert losses == 0.0 # No losses
assert self_consumption == 0.0 # No consumption
mock_battery.charge_energy.assert_not_called()
mock_battery.discharge_energy.assert_not_called()
inverter.self_consumption_predictor.calculate_self_consumption.assert_called_once_with(
consumption, generation
)
def test_process_energy_partial_battery_discharge(inverter, mock_battery):
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (50.0, 5.0)
generation = 200.0
consumption = 400.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in due to insufficient generation
assert grid_import == pytest.approx(
150.0, rel=1e-2
) # Grid supplies the shortfall after battery assist
assert losses == 5.0 # Discharge losses
assert self_consumption == 250.0 # Generation + battery discharge
mock_battery.charge_energy.assert_not_called()
mock_battery.discharge_energy.assert_called_once_with(200.0, 12)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_consumption_exceeds_max_no_battery(inverter, mock_battery):
# Battery is empty, and consumption is much higher than the inverter's max power
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (0.0, 0.0)
generation = 100.0
consumption = 1000.0 # Exceeds the inverter's max power
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in
assert grid_import == pytest.approx(900.0, rel=1e-2) # Grid covers the remaining shortfall
assert losses == 0.0 # No losses as the battery didnt assist
assert self_consumption == 100.0 # Only the generation is consumed, maxing out the inverter
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(400.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()
def test_process_energy_zero_generation_full_battery_high_consumption(inverter, mock_battery):
# Full battery, no generation, and high consumption
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.return_value = (500.0, 10.0)
generation = 0.0
consumption = 600.0
hour = 12
grid_export, grid_import, losses, self_consumption = inverter.process_energy(
generation, consumption, hour
)
assert grid_export == 0.0 # No feed-in due to zero generation
assert grid_import == pytest.approx(
100.0, rel=1e-2
) # Grid covers remaining shortfall after battery discharge
assert losses == 10.0 # Battery discharge losses
assert self_consumption == 500.0 # Battery fully discharges to meet consumption
mock_battery.charge_energy.assert_not_called()
2024-12-19 14:50:19 +01:00
mock_battery.discharge_energy.assert_called_once_with(500.0, hour)
inverter.self_consumption_predictor.calculate_self_consumption.assert_not_called()