EOS/tests/test_pvforecastakkudoktor.py

333 lines
11 KiB
Python
Raw Permalink Normal View History

import sys
from pathlib import Path
from unittest.mock import Mock, patch
import pytest
from akkudoktoreos.core.ems import get_ems
from akkudoktoreos.core.logging import get_logger
from akkudoktoreos.prediction.prediction import get_prediction
from akkudoktoreos.prediction.pvforecastakkudoktor import (
AkkudoktorForecastHorizon,
AkkudoktorForecastMeta,
AkkudoktorForecastValue,
PVForecastAkkudoktor,
PVForecastAkkudoktorDataRecord,
)
from akkudoktoreos.utils.datetimeutil import compare_datetimes, to_datetime, to_duration
DIR_TESTDATA = Path(__file__).absolute().parent.joinpath("testdata")
FILE_TESTDATA_PV_FORECAST_INPUT_1 = DIR_TESTDATA.joinpath("pv_forecast_input_1.json")
FILE_TESTDATA_PV_FORECAST_RESULT_1 = DIR_TESTDATA.joinpath("pv_forecast_result_1.txt")
logger = get_logger(__name__)
@pytest.fixture
def sample_settings(config_eos):
"""Fixture that adds settings data to the global config."""
settings = {
"general": {
"latitude": 52.52,
"longitude": 13.405,
},
"prediction": {
"hours": 48,
"historic_hours": 24,
},
"pvforecast": {
"provider": "PVForecastAkkudoktor",
"planes": [
{
"peakpower": 5.0,
"surface_azimuth": -10,
"surface_tilt": 7,
"userhorizon": [20, 27, 22, 20],
"inverter_paco": 10000,
},
{
"peakpower": 4.8,
"surface_azimuth": -90,
"surface_tilt": 7,
"userhorizon": [30, 30, 30, 50],
"inverter_paco": 10000,
},
{
"peakpower": 1.4,
"surface_azimuth": -40,
"surface_tilt": 60,
"userhorizon": [60, 30, 0, 30],
"inverter_paco": 2000,
},
{
"peakpower": 1.6,
"surface_azimuth": 5,
"surface_tilt": 45,
"userhorizon": [45, 25, 30, 60],
"inverter_paco": 1400,
},
],
},
}
# Merge settings to config
config_eos.merge_settings_from_dict(settings)
assert config_eos.pvforecast.provider == "PVForecastAkkudoktor"
return config_eos
@pytest.fixture
def sample_forecast_data():
"""Fixture that returns sample forecast data converted to pydantic model."""
Improve caching. (#431) * Move the caching module to core. Add an in memory cache that for caching function and method results during an energy management run (optimization run). Two decorators are provided for methods and functions. * Improve the file cache store by load and save functions. Make EOS load the cache file store on startup and save it on shutdown. Add a cyclic task that cleans the cache file store from outdated cache files. * Improve startup of EOSdash by EOS Make EOS starting EOSdash adhere to path configuration given in EOS. The whole environment from EOS is now passed to EOSdash. Should also prevent test errors due to unwanted/ wrong config file creation. Both servers now provide a health endpoint that can be used to detect whether the server is running. This is also used for testing now. * Improve startup of EOS EOS now has got an energy management task that runs shortly after startup. It tries to execute energy management runs with predictions newly fetched or initialized from cached data on first run. * Improve shutdown of EOS EOS has now a shutdown task that shuts EOS down gracefully with some time delay to allow REST API requests for shutdwon or restart to be fully serviced. * Improve EMS Add energy management task for repeated energy management controlled by startup delay and interval configuration parameters. Translate EnergieManagementSystem to english EnergyManagement. * Add administration endpoints - endpoints to control caching from REST API. - endpoints to control server restart (will not work on Windows) and shutdown from REST API * Improve doc generation Use "\n" linenend convention also on Windows when generating doc files. Replace Windows specific 127.0.0.1 address by standard 0.0.0.0. * Improve test support (to be able to test caching) - Add system test option to pytest for running tests with "real" resources - Add new test fixture to start server for test class and test function - Make kill signal adapt to Windows/ Linux - Use consistently "\n" for lineends when writing text files in doc test - Fix test_logging under Windows - Fix conftest config_default_dirs test fixture under Windows From @Lasall * Improve Windows support - Use 127.0.0.1 as default config host (model defaults) and addionally redirect 0.0.0.0 to localhost on Windows (because default config file still has 0.0.0.0). - Update install/startup instructions as package installation is required atm. Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
2025-02-12 21:35:51 +01:00
with FILE_TESTDATA_PV_FORECAST_INPUT_1.open("r", encoding="utf-8", newline=None) as f_in:
input_data = f_in.read()
return PVForecastAkkudoktor._validate_data(input_data)
@pytest.fixture
def sample_forecast_data_raw():
"""Fixture that returns raw sample forecast data."""
Improve caching. (#431) * Move the caching module to core. Add an in memory cache that for caching function and method results during an energy management run (optimization run). Two decorators are provided for methods and functions. * Improve the file cache store by load and save functions. Make EOS load the cache file store on startup and save it on shutdown. Add a cyclic task that cleans the cache file store from outdated cache files. * Improve startup of EOSdash by EOS Make EOS starting EOSdash adhere to path configuration given in EOS. The whole environment from EOS is now passed to EOSdash. Should also prevent test errors due to unwanted/ wrong config file creation. Both servers now provide a health endpoint that can be used to detect whether the server is running. This is also used for testing now. * Improve startup of EOS EOS now has got an energy management task that runs shortly after startup. It tries to execute energy management runs with predictions newly fetched or initialized from cached data on first run. * Improve shutdown of EOS EOS has now a shutdown task that shuts EOS down gracefully with some time delay to allow REST API requests for shutdwon or restart to be fully serviced. * Improve EMS Add energy management task for repeated energy management controlled by startup delay and interval configuration parameters. Translate EnergieManagementSystem to english EnergyManagement. * Add administration endpoints - endpoints to control caching from REST API. - endpoints to control server restart (will not work on Windows) and shutdown from REST API * Improve doc generation Use "\n" linenend convention also on Windows when generating doc files. Replace Windows specific 127.0.0.1 address by standard 0.0.0.0. * Improve test support (to be able to test caching) - Add system test option to pytest for running tests with "real" resources - Add new test fixture to start server for test class and test function - Make kill signal adapt to Windows/ Linux - Use consistently "\n" for lineends when writing text files in doc test - Fix test_logging under Windows - Fix conftest config_default_dirs test fixture under Windows From @Lasall * Improve Windows support - Use 127.0.0.1 as default config host (model defaults) and addionally redirect 0.0.0.0 to localhost on Windows (because default config file still has 0.0.0.0). - Update install/startup instructions as package installation is required atm. Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
2025-02-12 21:35:51 +01:00
with FILE_TESTDATA_PV_FORECAST_INPUT_1.open("r", encoding="utf-8", newline=None) as f_in:
input_data = f_in.read()
return input_data
@pytest.fixture
def sample_forecast_report():
"""Fixture that returns sample forecast data report."""
Improve caching. (#431) * Move the caching module to core. Add an in memory cache that for caching function and method results during an energy management run (optimization run). Two decorators are provided for methods and functions. * Improve the file cache store by load and save functions. Make EOS load the cache file store on startup and save it on shutdown. Add a cyclic task that cleans the cache file store from outdated cache files. * Improve startup of EOSdash by EOS Make EOS starting EOSdash adhere to path configuration given in EOS. The whole environment from EOS is now passed to EOSdash. Should also prevent test errors due to unwanted/ wrong config file creation. Both servers now provide a health endpoint that can be used to detect whether the server is running. This is also used for testing now. * Improve startup of EOS EOS now has got an energy management task that runs shortly after startup. It tries to execute energy management runs with predictions newly fetched or initialized from cached data on first run. * Improve shutdown of EOS EOS has now a shutdown task that shuts EOS down gracefully with some time delay to allow REST API requests for shutdwon or restart to be fully serviced. * Improve EMS Add energy management task for repeated energy management controlled by startup delay and interval configuration parameters. Translate EnergieManagementSystem to english EnergyManagement. * Add administration endpoints - endpoints to control caching from REST API. - endpoints to control server restart (will not work on Windows) and shutdown from REST API * Improve doc generation Use "\n" linenend convention also on Windows when generating doc files. Replace Windows specific 127.0.0.1 address by standard 0.0.0.0. * Improve test support (to be able to test caching) - Add system test option to pytest for running tests with "real" resources - Add new test fixture to start server for test class and test function - Make kill signal adapt to Windows/ Linux - Use consistently "\n" for lineends when writing text files in doc test - Fix test_logging under Windows - Fix conftest config_default_dirs test fixture under Windows From @Lasall * Improve Windows support - Use 127.0.0.1 as default config host (model defaults) and addionally redirect 0.0.0.0 to localhost on Windows (because default config file still has 0.0.0.0). - Update install/startup instructions as package installation is required atm. Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
2025-02-12 21:35:51 +01:00
with FILE_TESTDATA_PV_FORECAST_RESULT_1.open("r", encoding="utf-8", newline=None) as f_res:
input_data = f_res.read()
return input_data
@pytest.fixture
def sample_forecast_start(sample_forecast_data):
"""Fixture that returns the start date of the sample forecast data."""
forecast_start = to_datetime(sample_forecast_data.values[0][0].datetime)
expected_datetime = to_datetime("2024-10-06T00:00:00.000+02:00")
assert compare_datetimes(to_datetime(forecast_start), expected_datetime).equal
timezone_name = sample_forecast_data.meta.timezone
assert timezone_name == "Europe/Berlin"
return forecast_start
@pytest.fixture
def provider():
"""Fixture that returns the PVForecastAkkudoktor instance from the prediction."""
prediction = get_prediction()
provider = prediction.provider_by_id("PVForecastAkkudoktor")
assert isinstance(provider, PVForecastAkkudoktor)
return provider
@pytest.fixture
def provider_empty_instance():
"""Fixture that returns an empty instance of PVForecast."""
empty_instance = PVForecastAkkudoktor()
empty_instance.clear()
assert len(empty_instance) == 0
return empty_instance
# Sample data for testing
sample_horizon = AkkudoktorForecastHorizon(altitude=30, azimuthFrom=90, azimuthTo=180)
sample_meta = AkkudoktorForecastMeta(
lat=52.52,
lon=13.405,
power=[5000],
azimuth=[180],
tilt=[30],
timezone="Europe/Berlin",
albedo=0.25,
past_days=5,
inverterEfficiency=0.8,
powerInverter=[10000],
cellCoEff=-0.36,
range=True,
horizont=[[sample_horizon]],
horizontString=["sample_horizon"],
)
sample_value = AkkudoktorForecastValue(
datetime="2024-11-09T12:00:00",
dcPower=500.0,
power=480.0,
sunTilt=30.0,
sunAzimuth=180.0,
temperature=15.0,
relativehumidity_2m=50.0,
windspeed_10m=10.0,
)
sample_config_data = {
"general": {
"latitude": 52.52,
"longitude": 13.405,
},
"prediction": {
"hours": 48,
"historic_hours": 24,
},
"pvforecast": {
"provider": "PVForecastAkkudoktor",
"planes": [
{
"peakpower": 5.0,
"surface_azimuth": 180,
"surface_tilt": 30,
"inverter_paco": 10000,
}
],
},
}
# Tests for AkkudoktorForecastHorizon
def test_akkudoktor_forecast_horizon():
horizon = AkkudoktorForecastHorizon(altitude=30, azimuthFrom=90, azimuthTo=180)
assert horizon.altitude == 30
assert horizon.azimuthFrom == 90
assert horizon.azimuthTo == 180
# Tests for AkkudoktorForecastMeta
def test_akkudoktor_forecast_meta():
meta = sample_meta
assert meta.lat == 52.52
2025-01-02 18:34:55 +01:00
assert meta.lon == 13.405
assert meta.power == [5000]
assert meta.tilt == [30]
assert meta.timezone == "Europe/Berlin"
# Tests for AkkudoktorForecastValue
def test_akkudoktor_forecast_value():
value = sample_value
assert value.dcPower == 500.0
assert value.power == 480.0
assert value.temperature == 15.0
assert value.windspeed_10m == 10.0
# Tests for PVForecastAkkudoktorDataRecord
def test_pvforecast_akkudoktor_data_record():
record = PVForecastAkkudoktorDataRecord(
pvforecastakkudoktor_ac_power_measured=1000.0,
pvforecastakkudoktor_wind_speed_10m=10.0,
pvforecastakkudoktor_temp_air=15.0,
)
assert record.pvforecastakkudoktor_ac_power_measured == 1000.0
assert record.pvforecastakkudoktor_wind_speed_10m == 10.0
assert record.pvforecastakkudoktor_temp_air == 15.0
assert (
record.pvforecastakkudoktor_ac_power_any == 1000.0
) # Assuming AC power measured is preferred
def test_pvforecast_akkudoktor_validate_data(provider_empty_instance, sample_forecast_data_raw):
"""Test validation of PV forecast data on sample data."""
logger.info("The following errors are intentional and part of the test.")
with pytest.raises(
ValueError,
match="Field: meta\nError: Field required\nType: missing\nField: values\nError: Field required\nType: missing\n",
):
ret = provider_empty_instance._validate_data("{}")
data = provider_empty_instance._validate_data(sample_forecast_data_raw)
# everything worked
@patch("requests.get")
def test_pvforecast_akkudoktor_update_with_sample_forecast(
mock_get, sample_settings, sample_forecast_data_raw, sample_forecast_start, provider
):
"""Test data processing using sample forecast data."""
# Mock response object
mock_response = Mock()
mock_response.status_code = 200
mock_response.content = sample_forecast_data_raw
mock_get.return_value = mock_response
# Test that update properly inserts data records
ems_eos = get_ems()
ems_eos.set_start_datetime(sample_forecast_start)
provider.update_data(force_enable=True, force_update=True)
assert compare_datetimes(provider.start_datetime, sample_forecast_start).equal
assert compare_datetimes(provider[0].date_time, to_datetime(sample_forecast_start)).equal
# Report Generation Test
def test_report_ac_power_and_measurement(provider, config_eos):
# Set the configuration
config_eos.merge_settings_from_dict(sample_config_data)
record = PVForecastAkkudoktorDataRecord(
pvforecastakkudoktor_ac_power_measured=900.0,
pvforecast_dc_power=450.0,
pvforecast_ac_power=400.0,
)
provider.append(record)
report = provider.report_ac_power_and_measurement()
assert "DC: 450.0" in report
assert "AC: 400.0" in report
assert "AC sampled: 900.0" in report
@pytest.mark.skipif(
sys.platform.startswith("win"), reason="'other_timezone' fixture not supported on Windows"
)
@patch("requests.get")
def test_timezone_behaviour(
mock_get,
sample_settings,
sample_forecast_data_raw,
sample_forecast_start,
provider,
set_other_timezone,
):
"""Test PVForecast in another timezone."""
mock_response = Mock()
mock_response.status_code = 200
mock_response.content = sample_forecast_data_raw
mock_get.return_value = mock_response
# sample forecast start in other timezone
other_timezone = set_other_timezone()
other_start_datetime = to_datetime(sample_forecast_start, in_timezone=other_timezone)
assert compare_datetimes(other_start_datetime, sample_forecast_start).equal
expected_datetime = to_datetime("2024-10-06T00:00:00+0200", in_timezone=other_timezone)
assert compare_datetimes(other_start_datetime, expected_datetime).equal
provider.clear()
assert len(provider) == 0
ems_eos = get_ems()
ems_eos.set_start_datetime(other_start_datetime)
provider.update_data(force_update=True)
assert compare_datetimes(provider.start_datetime, other_start_datetime).equal
# Check wether first record starts at requested sample start time
assert compare_datetimes(provider[0].date_time, sample_forecast_start).equal
# Test updating AC power measurement for a specific date.
provider.update_value(sample_forecast_start, "pvforecastakkudoktor_ac_power_measured", 1000)
# Check wether first record was filled with ac power measurement
assert provider[0].pvforecastakkudoktor_ac_power_measured == 1000
# Test fetching temperature forecast for a specific date.
other_end_datetime = other_start_datetime + to_duration("24 hours")
expected_end_datetime = to_datetime("2024-10-07T00:00:00+0200", in_timezone=other_timezone)
assert compare_datetimes(other_end_datetime, expected_end_datetime).equal
forecast_temps = provider.key_to_series(
"pvforecastakkudoktor_temp_air", other_start_datetime, other_end_datetime
)
assert len(forecast_temps) == 23 # 24-1, first temperature is null
assert forecast_temps.iloc[0] == 6.5
assert forecast_temps.iloc[1] == 6.0
# Test fetching AC power forecast
other_end_datetime = other_start_datetime + to_duration("48 hours")
forecast_measured = provider.key_to_series(
"pvforecastakkudoktor_ac_power_measured", other_start_datetime, other_end_datetime
)
Fix2 config and predictions revamp. (#281) measurement: - Add new measurement class to hold real world measurements. - Handles load meter readings, grid import and export meter readings. - Aggregates load meter readings aka. measurements to total load. - Can import measurements from files, pandas datetime series, pandas datetime dataframes, simple daetime arrays and programmatically. - Maybe expanded to other measurement values. - Should be used for load prediction adaptions by real world measurements. core/coreabc: - Add mixin class to access measurements core/pydantic: - Add pydantic models for pandas datetime series and dataframes. - Add pydantic models for simple datetime array core/dataabc: - Provide DataImport mixin class for generic import handling. Imports from JSON string and files. Imports from pandas datetime dataframes and simple datetime arrays. Signature of import method changed to allow import datetimes to be given programmatically and by data content. - Use pydantic models for datetime series, dataframes, arrays - Validate generic imports by pydantic models - Provide new attributes min_datetime and max_datetime for DataSequence. - Add parameter dropna to drop NAN/ None values when creating lists, pandas series or numpy array from DataSequence. config/config: - Add common settings for the measurement module. predictions/elecpriceakkudoktor: - Use mean values of last 7 days to fill prediction values not provided by akkudoktor.net (only provides 24 values). prediction/loadabc: - Extend the generic prediction keys by 'load_total_adjusted' for load predictions that adjust the predicted total load by measured load values. prediction/loadakkudoktor: - Extend the Akkudoktor load prediction by load adjustment using measured load values. prediction/load_aggregator: - Module removed. Load aggregation is now handled by the measurement module. prediction/load_corrector: - Module removed. Load correction (aka. adjustment of load prediction by measured load energy) is handled by the LoadAkkudoktor prediction and the generic 'load_mean_adjusted' prediction key. prediction/load_forecast: - Module removed. Functionality now completely handled by the LoadAkkudoktor prediction. utils/cacheutil: - Use pydantic. - Fix potential bug in ttl (time to live) duration handling. utils/datetimeutil: - Added missing handling of pendulum.DateTime and pendulum.Duration instances as input. Handled before as datetime.datetime and datetime.timedelta. utils/visualize: - Move main to generate_example_report() for better testing support. server/server: - Added new configuration option server_fastapi_startup_server_fasthtml to make startup of FastHTML server by FastAPI server conditional. server/fastapi_server: - Add APIs for measurements - Improve APIs to provide or take pandas datetime series and datetime dataframes controlled by pydantic model. - Improve APIs to provide or take simple datetime data arrays controlled by pydantic model. - Move fastAPI server API to v1 for new APIs. - Update pre v1 endpoints to use new prediction and measurement capabilities. - Only start FastHTML server if 'server_fastapi_startup_server_fasthtml' config option is set. tests: - Adapt import tests to changed import method signature - Adapt server test to use the v1 API - Extend the dataabc test to test for array generation from data with several data interval scenarios. - Extend the datetimeutil test to also test for correct handling of to_datetime() providing now(). - Adapt LoadAkkudoktor test for new adjustment calculation. - Adapt visualization test to use example report function instead of visualize.py run as process. - Removed test_load_aggregator. Functionality is now tested in test_measurement. - Added tests for measurement module docs: - Remove sphinxcontrib-openapi as it prevents build of documentation. "site-packages/sphinxcontrib/openapi/openapi31.py", line 305, in _get_type_from_schema for t in schema["anyOf"]: KeyError: 'anyOf'" Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
2024-12-29 18:42:49 +01:00
assert len(forecast_measured) == 1
assert forecast_measured.iloc[0] == 1000.0 # changed before