Files
EOS/src/akkudoktoreos/optimization/genetic/terminalvalue.py
T

360 lines
13 KiB
Python
Raw Normal View History

"""Terminal value of the energy left in the battery at the end of the horizon.
The optimizer stops at the horizon, but the energy still stored in the battery
keeps its worth: it replaces grid imports that would otherwise be paid for
afterwards. Crediting that worth with a single price per kWh - the historical
``preis_euro_pro_wh_akku`` - cannot describe it, because the value of stored
energy is **not linear in the amount stored**:
- The first kWh replaces the most expensive hour after the horizon.
- The next one replaces the second most expensive hour, and so on.
- Once every hour that PV cannot cover is served, further energy replaces
nothing; it is worth an export at best, and nothing at worst.
The resulting value function is monotone and concave. A scalar has to pick one
slope: high enough for the first kWh means hoarding a full battery, low enough
for the last kWh means running it empty by midnight. This module builds the
curve instead.
There is no forecast beyond the horizon, so the trailing window of the horizon
itself stands in for the day that follows: same season, same household rhythm,
same tariff structure. That approximation is the reason the curve is a planning
aid, not a prediction - which is also why the marginal values are deliberately
conservative wherever a choice exists.
"""
from typing import Optional
import numpy as np
from loguru import logger
from pydantic import Field
from akkudoktoreos.core.pydantic import PydanticBaseModel
class TerminalValueCurve(PydanticBaseModel):
"""Piecewise linear, concave value of battery energy left at the horizon.
``energy_wh`` and ``value_euro`` are the breakpoints of the cumulative
value, ``marginal_euro_per_kwh`` the slope of each segment. Both arrays
start at the origin; the curve is flat beyond its last breakpoint.
"""
energy_wh: list[float] = Field(
default_factory=list,
json_schema_extra={
"description": "Breakpoints of usable AC energy left in the battery [Wh]."
},
)
value_euro: list[float] = Field(
default_factory=list,
json_schema_extra={"description": "Cumulative credit at each breakpoint [EUR]."},
)
operating_value_euro: list[float] = Field(
default_factory=list,
json_schema_extra={
"description": "Tail operating component at each breakpoint [EUR]; empty for a proxy curve."
},
)
continuation_value_euro: list[float] = Field(
default_factory=list,
json_schema_extra={
"description": "Continuation component at each breakpoint [EUR]; empty for a proxy curve."
},
)
marginal_euro_per_kwh: list[float] = Field(
default_factory=list,
json_schema_extra={
"description": (
"Marginal value of the segment that starts at each breakpoint "
"[EUR/kWh]. May be negative or non-monotone in TAIL mode."
)
},
)
residual_energy_wh: float = Field(
default=0.0,
json_schema_extra={
"description": (
"Energy up to which the curve is backed by residual load - the "
"knee. Everything beyond it is only worth an export."
)
},
)
window_slots: int = Field(
default=0,
json_schema_extra={
"description": (
"Number of trailing horizon slots the curve was derived from. "
"Fewer slots than a full day mean a shorter proxy period."
)
},
)
def value(self, energy_wh: float) -> float:
"""Return the credit for ``energy_wh`` of usable AC energy [EUR].
Args:
energy_wh: Usable AC energy left in the battery.
Returns:
Interpolated value of the curve; 0.0 for an empty curve.
"""
if not self.energy_wh or energy_wh <= 0.0:
return 0.0
return float(np.interp(energy_wh, self.energy_wh, self.value_euro))
class TailDiagnostics(PydanticBaseModel):
"""Forecast summary used by the deterministic tail optimization."""
slots: int = 0
slot_hours: float = 0.0
soc_grid_points: int = 0
min_import_price_euro_per_kwh: float = 0.0
max_import_price_euro_per_kwh: float = 0.0
min_feed_in_tariff_euro_per_kwh: float = 0.0
max_feed_in_tariff_euro_per_kwh: float = 0.0
negative_import_price_slots: int = 0
positive_battery_export_slots: int = 0
class TailPlanSlot(PydanticBaseModel):
"""One diagnostic slot of the optimal tail path.
These values explain the lookahead used for fitness. They are diagnostics
only and are never copied into the executable control arrays.
"""
slot: int
hour_from_start: float
action: str
alternative_action: str = ""
decision_margin_euro: float = 0.0
soc_start_percentage: float
soc_end_percentage: float
pv_wh: float
load_wh: float
grid_import_wh: float
grid_export_wh: float
battery_charge_wh: float
battery_discharge_wh: float
import_price_euro_per_kwh: float
feed_in_tariff_euro_per_kwh: float
slot_value_euro: float
remaining_value_euro: float
ac_charge_factor: float
dc_charge_allowed: int
discharge_allowed: int
battery_grid_export_factor: float
class TerminalValueResult(PydanticBaseModel):
"""What the optimizer credited for the energy left in the battery."""
control_horizon_hours: float = 0
requested_tail_hours: float = 0
effective_tail_hours: float = 0
tail_end_hour: float = 0
continuation_mode: str = "FIXED"
mode: str = Field(
json_schema_extra={
"description": "Terminal value mode the run used: TAIL, AUTO or FIXED.",
"examples": ["TAIL", "AUTO", "FIXED"],
}
)
battery_energy_wh: float = Field(
default=0.0,
json_schema_extra={
"description": "Usable AC energy left in the battery at the end of the horizon [Wh]."
},
)
credited_euro: float = Field(
default=0.0,
json_schema_extra={"description": "Credit applied to the total balance [EUR]."},
)
tail_operating_euro: float = Field(
default=0.0,
json_schema_extra={
"description": (
"Optimal net cash flow within the effective tail for the selected "
"control-end battery state [EUR]."
)
},
)
continuation_value_euro: float = Field(
default=0.0,
json_schema_extra={
"description": (
"Continuation credit remaining at the end of the optimal tail path [EUR]."
)
},
)
curve: Optional[TerminalValueCurve] = Field(
default=None,
json_schema_extra={
"description": (
"Combined tail value curve (tail operation plus continuation) read by fitness; "
"None in FIXED mode."
)
},
)
continuation_curve: Optional[TerminalValueCurve] = Field(
default=None,
json_schema_extra={
"description": "Conservative AUTO proxy constructed at the effective tail end."
},
)
tail_diagnostics: Optional[TailDiagnostics] = None
tail_plan: list[TailPlanSlot] = Field(
default_factory=list,
json_schema_extra={
"description": (
"Diagnostic optimal battery path inside the tail. It explains the "
"lookahead but is never an executable control plan."
)
},
)
reason: str = Field(
default="",
json_schema_extra={
"description": (
"Why this mode applied. Empty in AUTO mode; in FIXED mode it "
"says whether FIXED was configured or whether AUTO fell back "
"because no curve could be derived."
),
"examples": ["", "terminal_value_mode is FIXED"],
},
)
def build_terminal_value_curve(
*,
prices_euro_per_wh: np.ndarray,
load_wh: np.ndarray,
pv_wh: np.ndarray,
feed_in_euro_per_wh: np.ndarray,
max_energy_wh: float,
lcos_euro_per_kwh: float = 0.0,
dc_to_ac_efficiency: float = 1.0,
grid_export_allowed: bool = False,
) -> TerminalValueCurve:
"""Build the terminal value curve from the trailing horizon window.
Every slot of the window contributes its residual load - the part of the
load that PV does not cover - at its import price. Sorting those slots by
price and accumulating them yields the marginal value of the first, second,
... kWh in the battery. Energy beyond the residual load can only be
exported, and only when direct marketing allows it.
Args:
prices_euro_per_wh: Import prices of the window [EUR/Wh].
load_wh: Load per slot of the window [Wh].
pv_wh: PV generation per slot of the window [Wh].
feed_in_euro_per_wh: Feed-in tariff of the window [EUR/Wh].
max_energy_wh: Usable AC energy of a full battery [Wh]; the curve ends here.
lcos_euro_per_kwh: Levelized cost of storage, already charged per
delivered DC energy in the simulation and therefore subtracted here
so stored energy is not credited twice.
dc_to_ac_efficiency: Inverter efficiency, used to convert the LCOS from
delivered DC energy to the AC energy of the curve.
grid_export_allowed: Whether the battery may feed the grid (direct
marketing). Without it, energy beyond the residual load gets no
credit: it can neither be exported nor is its use covered by the
proxy window.
Returns:
The curve; empty when the window carries no usable information.
"""
window = min(len(prices_euro_per_wh), len(load_wh), len(pv_wh))
if window <= 0 or max_energy_wh <= 0.0:
return TerminalValueCurve()
residual = np.maximum(load_wh[:window] - pv_wh[:window], 0.0)
prices = np.asarray(prices_euro_per_wh[:window], dtype=float)
# LCOS is charged on delivered DC energy; the curve is in AC energy.
lcos_per_wh_ac = (lcos_euro_per_kwh / 1000.0) / max(dc_to_ac_efficiency, 1e-9)
order = np.argsort(-prices)
energy_points: list[float] = [0.0]
value_points: list[float] = [0.0]
marginals: list[float] = []
cumulative_energy = 0.0
cumulative_value = 0.0
for index in order:
slot_energy = float(residual[index])
if slot_energy <= 0.0:
continue
# Negative or very cheap hours are not worth storing energy for.
marginal = max(float(prices[index]) - lcos_per_wh_ac, 0.0)
if marginal <= 0.0:
continue
slot_energy = min(slot_energy, max_energy_wh - cumulative_energy)
if slot_energy <= 0.0:
break
cumulative_energy += slot_energy
cumulative_value += slot_energy * marginal
energy_points.append(cumulative_energy)
value_points.append(cumulative_value)
marginals.append(marginal * 1000.0)
# Everything beyond the residual load can only be sold. A median feed-in
# tariff rather than the best one: exporting all of it in the single best
# slot is not something the horizon can promise.
residual_energy_wh = cumulative_energy
if grid_export_allowed and cumulative_energy < max_energy_wh:
positive_feed_in = [
float(value) for value in feed_in_euro_per_wh[:window] if float(value) > 0.0
]
export_marginal = max(
(float(np.median(positive_feed_in)) if positive_feed_in else 0.0) - lcos_per_wh_ac,
0.0,
)
if export_marginal > 0.0:
remaining = max_energy_wh - cumulative_energy
cumulative_energy += remaining
cumulative_value += remaining * export_marginal
energy_points.append(cumulative_energy)
value_points.append(cumulative_value)
marginals.append(export_marginal * 1000.0)
if len(energy_points) <= 1:
logger.debug("Terminal value curve is empty - no priced residual load in the window.")
return TerminalValueCurve(window_slots=window)
# The segment slopes are decreasing by construction (prices were sorted),
# so the curve is concave; the export tail is the flattest segment.
return TerminalValueCurve(
energy_wh=energy_points,
value_euro=value_points,
marginal_euro_per_kwh=marginals,
residual_energy_wh=residual_energy_wh,
window_slots=window,
)
def trailing_window(
values: Optional[np.ndarray],
end_slot: int,
window_slots: int,
) -> np.ndarray:
"""Return the ``window_slots`` values in front of ``end_slot``.
Args:
values: Full slot array, or None.
end_slot: Exclusive end of the window (end of the optimization horizon).
window_slots: Desired window length; a shorter horizon yields less.
Returns:
The window as a float array, empty when no data is available.
"""
if values is None:
return np.zeros(0, dtype=float)
end = min(int(end_slot), len(values))
start = max(end - int(window_slots), 0)
if end <= start:
return np.zeros(0, dtype=float)
return np.asarray(values[start:end], dtype=float)