|   | % SPDX-License-Identifier: Apache-2.0 | |||
|  | (resource-page)= | |||
|  | 
 | |||
|  | # Resources (Device Simulations)
 | |||
|  | 
 | |||
|  | ## Concepts
 | |||
|  | 
 | |||
|  | The simulations for resources are leaning on general concepts of the [S2 standard]. | |||
|  | 
 | |||
|  | ### Control Types
 | |||
|  | 
 | |||
|  | The control of resources and such what a resource simulation will simulate follows three | |||
|  | basic control principles: | |||
|  | 
 | |||
|  | - Operation Mode Based Control (OMBC) | |||
|  | - Fill Rate Based Control (FRBC) | |||
|  | - Demand Driven Based Control (DDBC) | |||
|  | 
 | |||
|  | Although these control principles differ enough to separate them into three distinct control types, | |||
|  | there are some common aspects that make them similar: | |||
|  | 
 | |||
|  | - Operation Modes | |||
|  | - Transitions and | |||
|  | - Timers. | |||
|  | 
 | |||
|  | The objective for a control type is under which circumstances what things can be adjusted, and what | |||
|  | the constraints are for these adjustments. The three control types model a virtual, abstract resource | |||
|  | for simulation. | |||
|  | 
 | |||
|  | The abstract resource ignores all details of pyhsical device that are not relevant to energy | |||
|  | management. In addition, physical devices have an enormous variety in parameters, sensors, control | |||
|  | strategies, concerns, safeguards, and so on. It would be practically impossible to develop a | |||
|  | simulation that can | |||
|  | understand all the parameters of all the physical devices on the market. By making the resource more | |||
|  | abstract, its concepts can be translated to all sorts of physical devices, even though internally | |||
|  | they function very differently. As a consequence, it not always possible to make a 100% accurate | |||
|  | description of all the behaviors and constraints in these abstractions. But the abstractions used | |||
|  | in the control types are quite powerful, and should allow you to come pretty close. | |||
|  | 
 | |||
|  | The control types basically define how the simulated resource can be described. The user in the end | |||
|  | selects the proper desciption of a physical device using the configuration options provided for | |||
|  | resource simulations. The configuration sets how the simulated resource functions, what it can do and | |||
|  | what kind of constraints it has. | |||
|  | 
 | |||
|  | ### Resource Simulation
 | |||
|  | 
 | |||
|  | Based on the description of this virtual resource, the resource simulation can make predictions of | |||
|  | what the physical device will do in certain situations, and when it is allowed to execute | |||
|  | instructions generated by the optimization as part of the energy management plan evaluation. | |||
|  | 
 | |||
|  | ### Resource Status
 | |||
|  | 
 | |||
|  | Once the physical device has changed it's behavior, the resource simulation should be informed | |||
|  | to make the simulation change it's state accordingly. | |||
|  | 
 | |||
|  | The actual state of a pyhsical device may be reported to the resource simulation by the | |||
|  | **PUT** `/v1/resource/status` API endpoint. | |||
|  | 
 | |||
|  | ## Battery
 | |||
|  | 
 | |||
|  | There is a wealth of possible battery operation modes: | |||
|  | 
 | |||
|  | <!-- pyml disable line-length --> | |||
|  | | Mode                      | Purpose / Behavior                                                                      | Typical Trigger / Context                                        | | |||
|  | | ------------------------- | --------------------------------------------------------------------------------------- | ---------------------------------------------------------------- | | |||
|  | | **IDLE**                  | Battery neither charges nor discharges (SOC stable).                                    | No active control objective or power imbalance below thresholds. | | |||
|  | | **SELF_CONSUMPTION**      | Charge from PV surplus and discharge to cover local load.                               | PV generation > load (charge) or load > PV (discharge).          | | |||
|  | | **NON_EXPORT**   | Charge from on-site or local surplus with the goal of minimizing or preventing energy export to the external grid. Discharging to the grid is not allowed. | Export limit reached and SOC < SOC_max.                          | | |||
|  | | **PEAK_SHAVING**          | Discharge to keep grid import below a target threshold.                                 | Predicted or measured site load exceeds peak limit.              | | |||
|  | | **GRID_SUPPORT_EXPORT**   | Discharge energy to grid for revenue (V2G, wholesale market, flexibility service).      | Market or signal permits profitable export.                      | | |||
|  | | **GRID_SUPPORT_IMPORT**   | Charge from grid to absorb surplus or provide up-regulation service.                    | Low-price or grid-support signal detected.                       | | |||
|  | | **FREQUENCY_REGULATION**  | Rapid charge/discharge response to grid frequency deviations.                           | Active participation in frequency control.                       | | |||
|  | | **RAMP_RATE_CONTROL**     | Smooth site-level power ramp rates by buffering fluctuations.                           | Sudden PV/load change exceeding ramp limit.                      | | |||
|  | | **RESERVE_BACKUP**        | Maintain SOC ≥ reserve threshold to ensure backup capacity.                             | Resilience mode active, grid operational.                        | | |||
|  | | **OUTAGE_SUPPLY**         | Islanded operation: power local loads using stored energy (and PV if available).        | Grid failure detected.                                           | | |||
|  | | **FORCED_CHARGE**         | Manual or external control command to charge (e.g., pre-event, maintenance). No discharge.  | Operator or optimizer command. | | |||
|  | | **FORCED_DISCHARGE**      | Manual or external control command to discharge. No charge.                             | Operator or optimizer command.                                   | | |||
|  | | **FAULT**                 | Battery unavailable due to fault, safety, or protection state.                          | Fault detected (thermal, voltage, comms, etc.).                  | | |||
|  | <!-- pyml enable line-length --> | |||
|  | 
 | |||
|  | The optimization algorithm, the device simulation and the configuration properties only support the | |||
|  | most important of these modes. | |||
|  | 
 | |||
|  | ### Battery Simulation
 | |||
|  | 
 | |||
|  | The battery simulation assumes an idealized battery model. Under this model, the battery can be | |||
|  | operated in three discrete operation modes with fill rate based control (FRBC): | |||
|  | 
 | |||
|  | | **Operation Mode ID**    | **Description**                                                       | | |||
|  | | ------------------------ | --------------------------------------------------------------------- | | |||
|  | | **SELF_CONSUMPTION**     | Charge from local surplus and discharge to cover local load.          | | |||
|  | | **NON_EXPORT**           | Charge from local surplus and do not discharge.                       | | |||
|  | | **FORCED_CHARGE**        | Charge.                                                               | | |||
|  | 
 | |||
|  | The **operation mode factor** (0.0–1.0) specifies the normalized power rate relative to the | |||
|  | battery's nominal maximum charge or discharge power. A value of 1.0 corresponds to full-rate | |||
|  | charging or discharging, while 0.0 indicates no power transfer. Intermediate values scale the power | |||
|  | proportionally. | |||
|  | 
 | |||
|  | The **fill level** (0.0–1.0) specifies the normalized fill level relative to the | |||
|  | battery's nominal maximum charge. A value of 1.0 corresponds to full while 0.0 indicates empty. | |||
|  | Intermediate values scale the fill level proportionally. | |||
|  | 
 | |||
|  | ### Battery Configuration
 | |||
|  | 
 | |||
|  | ### Battery Stati
 | |||
|  | 
 | |||
|  | To keep the battery simulation in synchonization with the actual stati of the battery the following | |||
|  | resource stati may be reported to EOS by the **PUT** `/v1/resource/status` API endpoint. | |||
|  | 
 | |||
|  | #### Battery FRBCActuatorStatus
 | |||
|  | 
 | |||
|  | The operation mode the battery is currently operated. | |||
|  | 
 | |||
|  | ```json | |||
|  | { | |||
|  |   "type": "FRBCActuatorStatus", | |||
|  |   "active_operation_mode_id": "GRID_SUPPORT_IMPORT", | |||
|  |   "operation_mode_factor": "0.375", | |||
|  |   "previous_operation_mode_id": "SELF_CONSUMPTION", | |||
|  |   "transistion_timestamp": "20250725T12:00:12" | |||
|  | } | |||
|  | ``` | |||
|  | 
 | |||
|  | #### Battery FRBCStorageStatus
 | |||
|  | 
 | |||
|  | The current battery state of charge (SoC). | |||
|  | 
 | |||
|  | ```json | |||
|  | { | |||
|  |   "type": "FRBCStorageStatus", | |||
|  |   "present_fill_level": "0.88" | |||
|  | } | |||
|  | ``` | |||
|  | 
 | |||
|  | #### Battery PowerMeasurement
 | |||
|  | 
 | |||
|  | The current power that the battery is charged or discharged with \[W\]. | |||
|  | 
 | |||
|  | ```json | |||
|  | { | |||
|  |   "type": "PowerMeasurement", | |||
|  |   "measurement_timestamp": "20250725T12:00:12", | |||
|  |   "values": [ | |||
|  |     { | |||
|  |       "commodity_quantity": "ELECTRIC.POWER.L1", | |||
|  |       "value": "887.5" | |||
|  |     }, | |||
|  |     { | |||
|  |       "commodity_quantity": "ELECTRIC.POWER.L2", | |||
|  |       "value": "905.5" | |||
|  |     }, | |||
|  |     { | |||
|  |       "commodity_quantity": "ELECTRIC.POWER.L2", | |||
|  |       "value": "1100.7" | |||
|  |     }, | |||
|  |   ] | |||
|  | } | |||
|  | ``` | |||
|  | 
 | |||
|  | For symmetric (or unknown) power distribution: | |||
|  | 
 | |||
|  | ```json | |||
|  | { | |||
|  |   "type": "PowerMeasurement", | |||
|  |   "measurement_timestamp": "20250725T12:00:12", | |||
|  |   "values": [ | |||
|  |     { | |||
|  |       "commodity_quantity": "ELECTRIC.POWER.3_PHASE_SYM", | |||
|  |       "value": "1000" | |||
|  |     } | |||
|  |   ] | |||
|  | } | |||
|  | ``` | |||
|  | 
 | |||
|  | ## Electric Vehicle
 | |||
|  | 
 | |||
|  | The electric vehicle is basically a battery with a reduced set of operation modes. | |||
|  | 
 | |||
|  | ### Electric Vehicle Instructions
 | |||
|  | 
 | |||
|  | The electric vehicle control instructions assume an idealized EV battery model. Under this model, | |||
|  | the EV battery can be operated in two operation modes: | |||
|  | 
 | |||
|  | | **Operation Mode ID** | **Description**                                                         | | |||
|  | | --------------------- | ----------------------------------------------------------------------- | | |||
|  | | **IDLE**              | Battery neither charges nor discharges; holds its state of charge.      | | |||
|  | | **FORCED_CHARGE**     | Charge at a specified power rate up to the allowable maximum.           | | |||
|  | 
 | |||
|  | The **operation mode factor** (0.0–1.0) specifies the normalized power rate relative to the | |||
|  | battery's nominal maximum charge power. A value of 1.0 corresponds to full-rate charging, while 0.0 | |||
|  | indicates no power transfer. Intermediate values scale the power proportionally. | |||
|  | 
 | |||
|  | ## Home Appliance
 | |||
|  | 
 | |||
|  | The optimization algorithm supports one start of the home appliance within the optimization | |||
|  | horizon. | |||
|  | 
 | |||
|  | ### Home Appliance Simulation
 | |||
|  | 
 | |||
|  | ### Home Appliance Configuration
 | |||
|  | 
 | |||
|  | Home appliance to run within the optimization horizon. | |||
|  | 
 | |||
|  | ```json | |||
|  | [ | |||
|  |   { | |||
|  |     "device_id": "dishwasher1", | |||
|  |     "consumption_wh": 2000, | |||
|  |     "duration_h": 3 | |||
|  |   } | |||
|  | ] | |||
|  | ``` | |||
|  | 
 | |||
|  | Home appliance to run within a time window of 5 hours starting at 8:00 every day and another time | |||
|  | window of 3 hours starting at 15:00 every day. See | |||
|  | [Time Window Sequence Configuration](configtimewindow-page) for more information. | |||
|  | 
 | |||
|  | ```json | |||
|  | [ | |||
|  |   { | |||
|  |     "device_id": "dishwasher1", | |||
|  |     "consumption_wh": 2000, | |||
|  |     "duration_h": 3, | |||
|  |     "time_windows": { | |||
|  |       "windows": [ | |||
|  |         { | |||
|  |           "start_time": "08:00", | |||
|  |           "duration": "5 hours" | |||
|  |         }, | |||
|  |         { | |||
|  |           "start_time": "15:00", | |||
|  |           "duration": "3 hours" | |||
|  |         } | |||
|  |       ] | |||
|  |     } | |||
|  |   } | |||
|  | ] | |||
|  | ``` | |||
|  | 
 | |||
|  | :::{admonition} Note | |||
|  | :class: note | |||
|  | The optimization algorithm always restricts to one start within the optimization horizon per | |||
|  | energy management run. | |||
|  | ::: | |||
|  | 
 | |||
|  | ### Home Appliance Instructions
 | |||
|  | 
 | |||
|  | The home appliance instructions assume an idealized home appliance model. Under this model, | |||
|  | the home appliance can be operated in two operation modes: | |||
|  | 
 | |||
|  | | **Operation Mode ID** | **Description**                                                         | | |||
|  | |-----------------------|-------------------------------------------------------------------------| | |||
|  | | **RUN**               | The home appliance is started and runs until the end of it's power      | | |||
|  | |                       | sequence.                                                               | | |||
|  | | **IDLE**              | The home appliance does not run.                                        | | |||
|  | 
 | |||