Files
EOS/src/akkudoktoreos/measurement/batterycapacity.py
T

214 lines
8.8 KiB
Python
Raw Normal View History

"""Estimate effective model capacity from independent SoC anchors and DC power."""
from datetime import datetime
from math import isfinite
from typing import TYPE_CHECKING, Literal
from pydantic import AwareDatetime, BaseModel, ConfigDict, Field, model_validator
from akkudoktoreos.config.configabc import SettingsBaseModel
from akkudoktoreos.measurement.quality import SampleQuality
if TYPE_CHECKING:
from akkudoktoreos.measurement.measurement import MeasurementChannelSettings
class BatteryCapacityEstimationSettings(SettingsBaseModel):
"""Only a battery-terminal DC power channel is supported, not inverter AC."""
power_key: str = Field(min_length=1)
positive_power: Literal["charging", "discharging"]
measurement_boundary: Literal["battery_dc"] = "battery_dc"
min_soc_change_percentage: float = Field(default=20, gt=0, le=100)
max_duration_hours: float = Field(default=168, gt=0, le=744)
class CapacityModel(BaseModel):
model_config = ConfigDict(extra="forbid", allow_inf_nan=False)
class BatteryCapacityRequest(CapacityModel):
"""Caller attests both anchors are independent of the capacity being fitted.
End is the first confirmed full point when using the default end SoC.
Voltage/current anchors must be independently established for the chemistry.
"""
start: AwareDatetime
end: AwareDatetime
start_soc_percentage: float = Field(ge=0, le=100)
end_soc_percentage: float = Field(default=100, ge=0, le=100)
soc_reference: Literal["bms", "external_calibration", "voltage_current_anchor"]
store_estimate: bool = False
@model_validator(mode="after")
def ordered(self) -> "BatteryCapacityRequest":
if self.end.timestamp() <= self.start.timestamp():
raise ValueError("end must be after start.")
return self
class BatteryCapacityEstimate(CapacityModel):
battery_id: str
start: AwareDatetime
end: AwareDatetime
soc_reference: str
start_soc_percentage: float
end_soc_percentage: float
estimated_capacity_wh: float
configured_capacity_wh: float
capacity_change_percentage: float
model_end_soc_percentage_unclipped: float
model_soc_error_percentage_points: float
charge_energy_wh: float
discharge_energy_wh: float
stored_energy_change_wh: float
charging_efficiency: float
discharging_efficiency: float
power_key: str
positive_power: str
integration_method: str
coverage_seconds: float
samples_used: int
warnings: list[str]
def estimate_capacity(
request: BatteryCapacityRequest,
settings: BatteryCapacityEstimationSettings,
channel: "MeasurementChannelSettings",
samples: list[tuple[datetime, float | None, SampleQuality]],
*,
battery_id: str,
capacity_wh: float,
charging_efficiency: float,
discharging_efficiency: float,
) -> BatteryCapacityEstimate:
"""Fit C in C * delta_soc = eta_c * E_charge - E_discharge / eta_d.
No clipping at 0/100%, extrapolation, gap filling or efficiency fitting.
Linear segments are split at zero before applying directional efficiencies.
"""
left, right = request.start.timestamp(), request.end.timestamp()
if right - left > settings.max_duration_hours * 3600:
raise ValueError("Requested period exceeds capacity_estimation.max_duration_hours.")
delta_soc = (request.end_soc_percentage - request.start_soc_percentage) / 100
if abs(delta_soc) * 100 + 1e-9 < settings.min_soc_change_percentage:
raise ValueError(
"Independent SoC change is too small; full-to-full cannot identify capacity."
)
if channel.quantity != "power":
raise ValueError("Capacity estimation requires signed battery DC power in W or kW.")
max_gap_seconds = channel.max_gap_seconds
integration_method = channel.integration_method
if max_gap_seconds is None or integration_method is None:
raise ValueError("Power channels require an integration method and maximum sample gap.")
if not isfinite(capacity_wh) or capacity_wh <= 0:
raise ValueError("Configured capacity must be positive and finite.")
if not all(isfinite(e) and 0 < e <= 1 for e in (charging_efficiency, discharging_efficiency)):
raise ValueError("Battery efficiencies must be finite and in (0, 1].")
points = []
for time, value, quality in samples:
if time.tzinfo is None or time.utcoffset() is None:
raise ValueError("Explicit sample timezone required.")
points.append((time.timestamp(), value, quality))
points.sort(key=lambda row: row[0])
if any(a[0] == b[0] for a, b in zip(points, points[1:])):
raise ValueError("Duplicate power sample timestamps.")
factor = (1000 if channel.unit == "kW" else 1) * (
1 if settings.positive_power == "charging" else -1
)
charge = discharge = coverage = 0.0
cumulative_net = 0.0
minimum_net = maximum_net = 0.0
used: set[float] = set()
cursor = left
for (a, va, qa), (b, vb, qb) in zip(points, points[1:]):
lo, hi = max(left, a), min(right, b)
if hi <= lo:
continue
if lo > cursor + 1e-6 or b - a > max_gap_seconds:
raise ValueError("Incomplete power coverage or sample gap exceeds max_gap_seconds.")
if (
va is None
or vb is None
or any(isinstance(v, bool) or not isfinite(v) for v in (va, vb))
or qa.status != "measured"
or qb.status != "measured"
):
raise ValueError(
"Capacity estimation requires finite measured power samples throughout."
)
if qb.reset or qa.generation != qb.generation:
raise ValueError("Power sensor reset or generation change within the period.")
p, q = va * factor, vb * factor
if integration_method == "linear":
slope = (q - p) / (b - a)
p, q = p + slope * (lo - a), p + slope * (hi - a)
else:
q = p
duration = hi - lo
if p * q < 0:
first = duration * abs(p) / (abs(p) + abs(q))
parts = [(p * first / 7200), (q * (duration - first) / 7200)]
else:
parts = [(p + q) * duration / 7200]
charge += sum(max(0, energy) for energy in parts)
discharge += sum(max(0, -energy) for energy in parts)
for energy in parts:
cumulative_net += (
energy * charging_efficiency if energy >= 0 else energy / discharging_efficiency
)
minimum_net = min(minimum_net, cumulative_net)
maximum_net = max(maximum_net, cumulative_net)
coverage += duration
cursor = hi
used.update((a, b))
if cursor < right - 1e-6 or abs(coverage - (right - left)) > 1e-6:
raise ValueError("Incomplete power coverage; no extrapolation to the SoC anchors.")
net = charge * charging_efficiency - discharge / discharging_efficiency
capacity = net / delta_soc
if not isfinite(capacity) or capacity <= 0:
raise ValueError("Energy flow disagrees with SoC change; check polarity and anchors.")
if (
request.start_soc_percentage + minimum_net / capacity * 100 < -1e-6
or request.start_soc_percentage + maximum_net / capacity * 100 > 100 + 1e-6
):
raise ValueError(
"Fitted SoC leaves 0..100% within the period; check anchors and use the first full point."
)
model_end = request.start_soc_percentage + net / capacity_wh * 100
warnings = [
"Conditional estimate: SoC anchors, DC measurement boundary and configured efficiencies must be correct.",
"A single interval cannot independently identify both capacity and efficiencies.",
"The active capacity_wh is unchanged.",
]
if request.soc_reference == "voltage_current_anchor":
warnings.append(
"Voltage/current anchors depend on chemistry, temperature and operating conditions."
)
return BatteryCapacityEstimate(
battery_id=battery_id,
start=request.start,
end=request.end,
soc_reference=request.soc_reference,
start_soc_percentage=request.start_soc_percentage,
end_soc_percentage=request.end_soc_percentage,
estimated_capacity_wh=capacity,
configured_capacity_wh=capacity_wh,
capacity_change_percentage=(capacity / capacity_wh - 1) * 100,
model_end_soc_percentage_unclipped=model_end,
model_soc_error_percentage_points=model_end - request.end_soc_percentage,
charge_energy_wh=charge,
discharge_energy_wh=discharge,
stored_energy_change_wh=net,
charging_efficiency=charging_efficiency,
discharging_efficiency=discharging_efficiency,
power_key=settings.power_key,
positive_power=settings.positive_power,
integration_method=integration_method,
coverage_seconds=coverage,
samples_used=len(used),
warnings=warnings,
)