2025-11-13 22:53:46 +01:00
## Base configuration for devices simulation settings
<!-- pyml disable line - length -->
:::{table} devices
:widths: 10 20 10 5 5 30
:align: left
| Name | Environment Variable | Type | Read-Only | Default | Description |
| ---- | -------------------- | ---- | --------- | ------- | ----------- |
| batteries | `EOS_DEVICES__BATTERIES` | `Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]]` | `rw` | `None` | List of battery devices |
| electric_vehicles | `EOS_DEVICES__ELECTRIC_VEHICLES` | `Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]]` | `rw` | `None` | List of electric vehicle devices |
| home_appliances | `EOS_DEVICES__HOME_APPLIANCES` | `Optional[list[akkudoktoreos.devices.devices.HomeApplianceCommonSettings]]` | `rw` | `None` | List of home appliances |
| inverters | `EOS_DEVICES__INVERTERS` | `Optional[list[akkudoktoreos.devices.devices.InverterCommonSettings]]` | `rw` | `None` | List of inverters |
| max_batteries | `EOS_DEVICES__MAX_BATTERIES` | `Optional[int]` | `rw` | `None` | Maximum number of batteries that can be set |
| max_electric_vehicles | `EOS_DEVICES__MAX_ELECTRIC_VEHICLES` | `Optional[int]` | `rw` | `None` | Maximum number of electric vehicles that can be set |
| max_home_appliances | `EOS_DEVICES__MAX_HOME_APPLIANCES` | `Optional[int]` | `rw` | `None` | Maximum number of home_appliances that can be set |
| max_inverters | `EOS_DEVICES__MAX_INVERTERS` | `Optional[int]` | `rw` | `None` | Maximum number of inverters that can be set |
2025-12-30 22:08:21 +01:00
| measurement_keys | | `Optional[list[str]]` | `ro` | `N/A` | Return the measurement keys for the resource/ device stati that are measurements. |
2025-11-13 22:53:46 +01:00
:::
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Input**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
2025-12-30 22:08:21 +01:00
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
2025-11-13 22:53:46 +01:00
"min_soc_percentage": 0,
Add database support for measurements and historic prediction data. (#848)
The database supports backend selection, compression, incremental data load,
automatic data saving to storage, automatic vaccum and compaction.
Make SQLite3 and LMDB database backends available.
Update tests for new interface conventions regarding data sequences,
data containers, data providers. This includes the measurements provider and
the prediction providers.
Add database documentation.
The fix includes several bug fixes that are not directly related to the database
implementation but are necessary to keep EOS running properly and to test and
document the changes.
* fix: config eos test setup
Make the config_eos fixture generate a new instance of the config_eos singleton.
Use correct env names to setup data folder path.
* fix: startup with no config
Make cache and measurements complain about missing data path configuration but
do not bail out.
* fix: soc data preparation and usage for genetic optimization.
Search for soc measurments 48 hours around the optimization start time.
Only clamp soc to maximum in battery device simulation.
* fix: dashboard bailout on zero value solution display
Do not use zero values to calculate the chart values adjustment for display.
* fix: openapi generation script
Make the script also replace data_folder_path and data_output_path to hide
real (test) environment pathes.
* feat: add make repeated task function
make_repeated_task allows to wrap a function to be repeated cyclically.
* chore: removed index based data sequence access
Index based data sequence access does not make sense as the sequence can be backed
by the database. The sequence is now purely time series data.
* chore: refactor eos startup to avoid module import startup
Avoid module import initialisation expecially of the EOS configuration.
Config mutation, singleton initialization, logging setup, argparse parsing,
background task definitions depending on config and environment-dependent behavior
is now done at function startup.
* chore: introduce retention manager
A single long-running background task that owns the scheduling of all periodic
server-maintenance jobs (cache cleanup, DB autosave, …)
* chore: canonicalize timezone name for UTC
Timezone names that are semantically identical to UTC are canonicalized to UTC.
* chore: extend config file migration for default value handling
Extend the config file migration handling values None or nonexisting values
that will invoke a default value generation in the new config file. Also
adapt test to handle this situation.
* chore: extend datetime util test cases
* chore: make version test check for untracked files
Check for files that are not tracked by git. Version calculation will be
wrong if these files will not be commited.
* chore: bump pandas to 3.0.0
Pandas 3.0 now performs inference on the appropriate resolution (a.k.a. unit)
for the output dtype which may become datetime64[us] (before it was ns). Also
numeric dtype detection is now more strict which needs a different detection for
numerics.
* chore: bump pydantic-settings to 2.12.0
pydantic-settings 2.12.0 under pytest creates a different behaviour. The tests
were adapted and a workaround was introduced. Also ConfigEOS was adapted
to allow for fine grain initialization control to be able to switch
off certain settings such as file settings during test.
* chore: remove sci learn kit from dependencies
The sci learn kit is not strictly necessary as long as we have scipy.
* chore: add documentation mode guarding for sphinx autosummary
Sphinx autosummary excecutes functions. Prevent exceptions in case of pure doc
mode.
* chore: adapt docker-build CI workflow to stricter GitHub handling
Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
2026-02-22 14:12:42 +01:00
"max_soc_percentage": 100
2025-11-13 22:53:46 +01:00
}
],
"max_batteries": 1,
"electric_vehicles": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
2025-12-30 22:08:21 +01:00
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
2025-11-13 22:53:46 +01:00
"min_soc_percentage": 0,
Add database support for measurements and historic prediction data. (#848)
The database supports backend selection, compression, incremental data load,
automatic data saving to storage, automatic vaccum and compaction.
Make SQLite3 and LMDB database backends available.
Update tests for new interface conventions regarding data sequences,
data containers, data providers. This includes the measurements provider and
the prediction providers.
Add database documentation.
The fix includes several bug fixes that are not directly related to the database
implementation but are necessary to keep EOS running properly and to test and
document the changes.
* fix: config eos test setup
Make the config_eos fixture generate a new instance of the config_eos singleton.
Use correct env names to setup data folder path.
* fix: startup with no config
Make cache and measurements complain about missing data path configuration but
do not bail out.
* fix: soc data preparation and usage for genetic optimization.
Search for soc measurments 48 hours around the optimization start time.
Only clamp soc to maximum in battery device simulation.
* fix: dashboard bailout on zero value solution display
Do not use zero values to calculate the chart values adjustment for display.
* fix: openapi generation script
Make the script also replace data_folder_path and data_output_path to hide
real (test) environment pathes.
* feat: add make repeated task function
make_repeated_task allows to wrap a function to be repeated cyclically.
* chore: removed index based data sequence access
Index based data sequence access does not make sense as the sequence can be backed
by the database. The sequence is now purely time series data.
* chore: refactor eos startup to avoid module import startup
Avoid module import initialisation expecially of the EOS configuration.
Config mutation, singleton initialization, logging setup, argparse parsing,
background task definitions depending on config and environment-dependent behavior
is now done at function startup.
* chore: introduce retention manager
A single long-running background task that owns the scheduling of all periodic
server-maintenance jobs (cache cleanup, DB autosave, …)
* chore: canonicalize timezone name for UTC
Timezone names that are semantically identical to UTC are canonicalized to UTC.
* chore: extend config file migration for default value handling
Extend the config file migration handling values None or nonexisting values
that will invoke a default value generation in the new config file. Also
adapt test to handle this situation.
* chore: extend datetime util test cases
* chore: make version test check for untracked files
Check for files that are not tracked by git. Version calculation will be
wrong if these files will not be commited.
* chore: bump pandas to 3.0.0
Pandas 3.0 now performs inference on the appropriate resolution (a.k.a. unit)
for the output dtype which may become datetime64[us] (before it was ns). Also
numeric dtype detection is now more strict which needs a different detection for
numerics.
* chore: bump pydantic-settings to 2.12.0
pydantic-settings 2.12.0 under pytest creates a different behaviour. The tests
were adapted and a workaround was introduced. Also ConfigEOS was adapted
to allow for fine grain initialization control to be able to switch
off certain settings such as file settings during test.
* chore: remove sci learn kit from dependencies
The sci learn kit is not strictly necessary as long as we have scipy.
* chore: add documentation mode guarding for sphinx autosummary
Sphinx autosummary excecutes functions. Prevent exceptions in case of pure doc
mode.
* chore: adapt docker-build CI workflow to stricter GitHub handling
Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
2026-02-22 14:12:42 +01:00
"max_soc_percentage": 100
2025-11-13 22:53:46 +01:00
}
],
"max_electric_vehicles": 1,
"inverters": [],
"max_inverters": 1,
"home_appliances": [],
"max_home_appliances": 1
}
}
```
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Output**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
2025-12-30 22:08:21 +01:00
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
2025-11-13 22:53:46 +01:00
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"measurement_key_soc_factor": "battery1-soc-factor",
"measurement_key_power_l1_w": "battery1-power-l1-w",
"measurement_key_power_l2_w": "battery1-power-l2-w",
"measurement_key_power_l3_w": "battery1-power-l3-w",
"measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
],
"max_batteries": 1,
"electric_vehicles": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.0,
"max_charge_power_w": 5000,
"min_charge_power_w": 50,
2025-12-30 22:08:21 +01:00
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
2025-11-13 22:53:46 +01:00
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"measurement_key_soc_factor": "battery1-soc-factor",
"measurement_key_power_l1_w": "battery1-power-l1-w",
"measurement_key_power_l2_w": "battery1-power-l2-w",
"measurement_key_power_l3_w": "battery1-power-l3-w",
"measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
],
"max_electric_vehicles": 1,
"inverters": [],
"max_inverters": 1,
"home_appliances": [],
"max_home_appliances": 1,
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w",
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
}
```
<!-- pyml enable line - length -->
### Inverter devices base settings
<!-- pyml disable line - length -->
:::{table} devices::inverters::list
:widths: 10 10 5 5 30
:align: left
| Name | Type | Read-Only | Default | Description |
| ---- | ---- | --------- | ------- | ----------- |
| battery_id | `Optional[str]` | `rw` | `None` | ID of battery controlled by this inverter. |
| device_id | `str` | `rw` | `<unknown>` | ID of device |
| max_power_w | `Optional[float]` | `rw` | `None` | Maximum power [W]. |
2025-12-30 22:08:21 +01:00
| measurement_keys | `Optional[list[str]]` | `ro` | `N/A` | Measurement keys for the inverter stati that are measurements. |
2025-11-13 22:53:46 +01:00
:::
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Input**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"inverters": [
{
"device_id": "battery1",
"max_power_w": 10000.0,
"battery_id": null
}
]
}
}
```
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Output**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"inverters": [
{
"device_id": "battery1",
"max_power_w": 10000.0,
"battery_id": null,
"measurement_keys": []
}
]
}
}
```
<!-- pyml enable line - length -->
### Home Appliance devices base settings
<!-- pyml disable line - length -->
:::{table} devices::home_appliances::list
:widths: 10 10 5 5 30
:align: left
| Name | Type | Read-Only | Default | Description |
| ---- | ---- | --------- | ------- | ----------- |
| consumption_wh | `int` | `rw` | `required` | Energy consumption [Wh]. |
| device_id | `str` | `rw` | `<unknown>` | ID of device |
| duration_h | `int` | `rw` | `required` | Usage duration in hours [0 ... 24]. |
2025-12-30 22:08:21 +01:00
| measurement_keys | `Optional[list[str]]` | `ro` | `N/A` | Measurement keys for the home appliance stati that are measurements. |
2025-11-13 22:53:46 +01:00
| time_windows | `Optional[akkudoktoreos.utils.datetimeutil.TimeWindowSequence]` | `rw` | `None` | Sequence of allowed time windows. Defaults to optimization general time window. |
:::
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Input**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"home_appliances": [
{
"device_id": "battery1",
"consumption_wh": 2000,
"duration_h": 1,
"time_windows": {
"windows": [
{
"start_time": "10:00:00.000000 Europe/Berlin",
"duration": "2 hours",
"day_of_week": null,
"date": null,
"locale": null
}
]
}
}
]
}
}
```
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Output**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"home_appliances": [
{
"device_id": "battery1",
"consumption_wh": 2000,
"duration_h": 1,
"time_windows": {
"windows": [
{
"start_time": "10:00:00.000000 Europe/Berlin",
"duration": "2 hours",
"day_of_week": null,
"date": null,
"locale": null
}
]
},
"measurement_keys": []
}
]
}
}
```
<!-- pyml enable line - length -->
### Battery devices base settings
<!-- pyml disable line - length -->
:::{table} devices::batteries::list
:widths: 10 10 5 5 30
:align: left
| Name | Type | Read-Only | Default | Description |
| ---- | ---- | --------- | ------- | ----------- |
| capacity_wh | `int` | `rw` | `8000` | Capacity [Wh]. |
2025-12-30 22:08:21 +01:00
| charge_rates | `Optional[list[float]]` | `rw` | `[0.0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0]` | Charge rates as factor of maximum charging power [0.00 ... 1.00]. None triggers fallback to default charge-rates. |
2025-11-13 22:53:46 +01:00
| charging_efficiency | `float` | `rw` | `0.88` | Charging efficiency [0.01 ... 1.00]. |
| device_id | `str` | `rw` | `<unknown>` | ID of device |
| discharging_efficiency | `float` | `rw` | `0.88` | Discharge efficiency [0.01 ... 1.00]. |
| levelized_cost_of_storage_kwh | `float` | `rw` | `0.0` | Levelized cost of storage (LCOS), the average lifetime cost of delivering one kWh [€/kWh]. |
| max_charge_power_w | `Optional[float]` | `rw` | `5000` | Maximum charging power [W]. |
| max_soc_percentage | `int` | `rw` | `100` | Maximum state of charge (SOC) as percentage of capacity [%]. |
2025-12-30 22:08:21 +01:00
| measurement_key_power_3_phase_sym_w | `str` | `ro` | `N/A` | Measurement key for the symmetric 3 phase power the battery is charged or discharged with [W]. |
| measurement_key_power_l1_w | `str` | `ro` | `N/A` | Measurement key for the L1 power the battery is charged or discharged with [W]. |
| measurement_key_power_l2_w | `str` | `ro` | `N/A` | Measurement key for the L2 power the battery is charged or discharged with [W]. |
| measurement_key_power_l3_w | `str` | `ro` | `N/A` | Measurement key for the L3 power the battery is charged or discharged with [W]. |
| measurement_key_soc_factor | `str` | `ro` | `N/A` | Measurement key for the battery state of charge (SoC) as factor of total capacity [0.0 ... 1.0]. |
| measurement_keys | `Optional[list[str]]` | `ro` | `N/A` | Measurement keys for the battery stati that are measurements. |
2025-11-13 22:53:46 +01:00
| min_charge_power_w | `Optional[float]` | `rw` | `50` | Minimum charging power [W]. |
| min_soc_percentage | `int` | `rw` | `0` | Minimum state of charge (SOC) as percentage of capacity [%]. This is the target SoC for charging |
:::
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Input**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.12,
"max_charge_power_w": 5000.0,
"min_charge_power_w": 50.0,
2025-12-30 22:08:21 +01:00
"charge_rates": [
0.0,
0.25,
0.5,
0.75,
1.0
],
2025-11-13 22:53:46 +01:00
"min_soc_percentage": 10,
"max_soc_percentage": 100
}
]
}
}
```
<!-- pyml enable line - length -->
<!-- pyml disable no - emphasis - as - heading -->
**Example Output**
<!-- pyml enable no - emphasis - as - heading -->
<!-- pyml disable line - length -->
```json
{
"devices": {
"batteries": [
{
"device_id": "battery1",
"capacity_wh": 8000,
"charging_efficiency": 0.88,
"discharging_efficiency": 0.88,
"levelized_cost_of_storage_kwh": 0.12,
"max_charge_power_w": 5000.0,
"min_charge_power_w": 50.0,
2025-12-30 22:08:21 +01:00
"charge_rates": [
0.0,
0.25,
0.5,
0.75,
1.0
],
2025-11-13 22:53:46 +01:00
"min_soc_percentage": 10,
"max_soc_percentage": 100,
"measurement_key_soc_factor": "battery1-soc-factor",
"measurement_key_power_l1_w": "battery1-power-l1-w",
"measurement_key_power_l2_w": "battery1-power-l2-w",
"measurement_key_power_l3_w": "battery1-power-l3-w",
"measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
"measurement_keys": [
"battery1-soc-factor",
"battery1-power-l1-w",
"battery1-power-l2-w",
"battery1-power-l3-w",
"battery1-power-3-phase-sym-w"
]
}
]
}
}
```
<!-- pyml enable line - length -->