2024-05-02 10:27:33 +02:00
|
|
|
class Wechselrichter:
|
|
|
|
def __init__(self, max_leistung_wh, akku):
|
2024-09-20 12:35:38 +02:00
|
|
|
self.max_leistung_wh = max_leistung_wh # Maximum power that the inverter can handle
|
|
|
|
self.akku = akku # Connection to a battery object
|
2024-05-02 10:27:33 +02:00
|
|
|
|
|
|
|
def energie_verarbeiten(self, erzeugung, verbrauch, hour):
|
2024-09-20 12:35:38 +02:00
|
|
|
verluste = 0 # Losses during processing
|
|
|
|
netzeinspeisung = 0 # Grid feed-in
|
|
|
|
netzbezug = 0.0 # Grid draw
|
|
|
|
eigenverbrauch = 0.0 # Self-consumption
|
2024-05-02 10:27:33 +02:00
|
|
|
|
2024-07-30 09:22:55 +02:00
|
|
|
if erzeugung >= verbrauch:
|
2024-05-02 10:27:33 +02:00
|
|
|
if verbrauch > self.max_leistung_wh:
|
2024-09-20 12:35:38 +02:00
|
|
|
# If consumption exceeds maximum inverter power
|
2024-05-02 10:27:33 +02:00
|
|
|
verluste += erzeugung - self.max_leistung_wh
|
2024-09-20 12:35:38 +02:00
|
|
|
restleistung_nach_verbrauch = self.max_leistung_wh - verbrauch
|
|
|
|
netzbezug = -restleistung_nach_verbrauch # Negative indicates feeding into the grid
|
2024-05-02 10:27:33 +02:00
|
|
|
eigenverbrauch = self.max_leistung_wh
|
2024-09-20 12:35:38 +02:00
|
|
|
else:
|
|
|
|
# Remaining power after consumption
|
|
|
|
restleistung_nach_verbrauch = erzeugung - verbrauch
|
2024-05-02 10:27:33 +02:00
|
|
|
|
2024-09-20 12:35:38 +02:00
|
|
|
# Load battery with excess energy
|
2024-05-02 10:27:33 +02:00
|
|
|
geladene_energie, verluste_laden_akku = self.akku.energie_laden(restleistung_nach_verbrauch, hour)
|
2024-09-20 12:35:38 +02:00
|
|
|
rest_überschuss = restleistung_nach_verbrauch - (geladene_energie + verluste_laden_akku)
|
|
|
|
|
|
|
|
# Feed-in to the grid based on remaining capacity
|
2024-05-02 10:27:33 +02:00
|
|
|
if rest_überschuss > self.max_leistung_wh - verbrauch:
|
|
|
|
netzeinspeisung = self.max_leistung_wh - verbrauch
|
|
|
|
verluste += rest_überschuss - netzeinspeisung
|
|
|
|
else:
|
|
|
|
netzeinspeisung = rest_überschuss
|
2024-09-20 12:35:38 +02:00
|
|
|
|
2024-05-02 10:27:33 +02:00
|
|
|
verluste += verluste_laden_akku
|
2024-09-20 12:35:38 +02:00
|
|
|
eigenverbrauch = verbrauch # Self-consumption is equal to the load
|
2024-05-02 10:27:33 +02:00
|
|
|
|
|
|
|
else:
|
2024-09-20 12:35:38 +02:00
|
|
|
benötigte_energie = verbrauch - erzeugung # Energy needed from external sources
|
|
|
|
max_akku_leistung = self.akku.max_ladeleistung_w # Maximum battery discharge power
|
2024-05-02 10:27:33 +02:00
|
|
|
|
2024-09-20 12:35:38 +02:00
|
|
|
# Calculate remaining AC power available
|
|
|
|
rest_ac_leistung = max(self.max_leistung_wh - erzeugung, 0)
|
2024-05-02 10:27:33 +02:00
|
|
|
|
2024-09-20 12:35:38 +02:00
|
|
|
# Discharge energy from the battery based on need
|
2024-05-02 10:27:33 +02:00
|
|
|
if benötigte_energie < rest_ac_leistung:
|
|
|
|
aus_akku, akku_entladeverluste = self.akku.energie_abgeben(benötigte_energie, hour)
|
2024-09-20 12:35:38 +02:00
|
|
|
else:
|
2024-05-02 10:27:33 +02:00
|
|
|
aus_akku, akku_entladeverluste = self.akku.energie_abgeben(rest_ac_leistung, hour)
|
|
|
|
|
2024-09-20 12:35:38 +02:00
|
|
|
verluste += akku_entladeverluste # Include losses from battery discharge
|
|
|
|
netzbezug = benötigte_energie - aus_akku # Energy drawn from the grid
|
|
|
|
eigenverbrauch = erzeugung + aus_akku # Total self-consumption
|
2024-05-02 10:27:33 +02:00
|
|
|
|
|
|
|
return netzeinspeisung, netzbezug, verluste, eigenverbrauch
|