| batteries | `EOS_DEVICES__BATTERIES` | `Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]]` | `rw` | `None` | List of battery devices |
| electric_vehicles | `EOS_DEVICES__ELECTRIC_VEHICLES` | `Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]]` | `rw` | `None` | List of electric vehicle devices |
| home_appliances | `EOS_DEVICES__HOME_APPLIANCES` | `Optional[list[akkudoktoreos.devices.devices.HomeApplianceCommonSettings]]` | `rw` | `None` | List of home appliances |
| inverters | `EOS_DEVICES__INVERTERS` | `Optional[list[akkudoktoreos.devices.devices.InverterCommonSettings]]` | `rw` | `None` | List of inverters |
| max_batteries | `EOS_DEVICES__MAX_BATTERIES` | `Optional[int]` | `rw` | `None` | Maximum number of batteries that can be set |
| max_electric_vehicles | `EOS_DEVICES__MAX_ELECTRIC_VEHICLES` | `Optional[int]` | `rw` | `None` | Maximum number of electric vehicles that can be set |
| max_home_appliances | `EOS_DEVICES__MAX_HOME_APPLIANCES` | `Optional[int]` | `rw` | `None` | Maximum number of home_appliances that can be set |
| max_inverters | `EOS_DEVICES__MAX_INVERTERS` | `Optional[int]` | `rw` | `None` | Maximum number of inverters that can be set |
| measurement_keys | | `Optional[list[str]]` | `ro` | `N/A` | Return the measurement keys for the resource/ device stati that are measurements. |
| ac_to_dc_efficiency | `float` | `rw` | `1.0` | Efficiency of AC to DC conversion for grid-to-battery AC charging (0-1). Set to 0 to disable AC charging. Default 1.0 (no additional inverter loss). |
| dc_to_ac_efficiency | `float` | `rw` | `1.0` | Efficiency of DC to AC conversion for battery discharging to AC load/grid (0-1). Default 1.0 (no additional inverter loss). |
| max_ac_charge_power_w | `Optional[float]` | `rw` | `None` | Maximum AC charging power in watts. null means no additional limit. Set to 0 to disable AC charging. |
| max_power_w | `Optional[float]` | `rw` | `None` | Maximum power [W]. |
| measurement_keys | `Optional[list[str]]` | `ro` | `N/A` | Measurement keys for the inverter stati that are measurements. |
| date | `Optional[pydantic_extra_types.pendulum_dt.Date]` | `rw` | `None` | Optional specific calendar date for the time window. Naive — matched against the local date of the datetime passed to contains(). Overrides `day_of_week` if set. |
| day_of_week | `Union[int, str, NoneType]` | `rw` | `None` | Optional day of the week restriction. Can be specified as integer (0=Monday to 6=Sunday) or localized weekday name. If None, applies every day unless `date` is set. |
| duration | `Duration` | `rw` | `required` | Duration of the time window starting from `start_time`. |
| locale | `Optional[str]` | `rw` | `None` | Locale used to parse weekday names in `day_of_week` when given as string. If not set, Pendulum's default locale is used. Examples: 'en', 'de', 'fr', etc. |
| start_time | `Time` | `rw` | `required` | Naive start time of the time window (time of day, no timezone). Interpreted in the timezone of the datetime passed to contains() or earliest_start_time(). |
:::
<!-- pyml enable line-length -->
<!-- pyml disable no-emphasis-as-heading -->
**Example Input/Output**
<!-- pyml enable no-emphasis-as-heading -->
<!-- pyml disable line-length -->
```json
{
"devices": {
"home_appliances": [
{
"time_windows": {
"windows": [
{
"start_time": "00:00:00.000000",
"duration": "2 hours",
"day_of_week": null,
"date": null,
"locale": null
}
]
}
}
]
}
}
```
<!-- pyml enable line-length -->
### Model representing a sequence of time windows with collective operations
Manages multiple TimeWindow objects and provides methods to work with them
as a cohesive unit for scheduling and availability checking.
| consumption_wh | `Optional[int]` | `rw` | `None` | Flat fallback: total energy consumption of one run [Wh]. Used only when no load_profile_power_w is given. |
| duration_h | `Optional[int]` | `rw` | `None` | Flat fallback: run duration in hours [0 ... 24]. Used only when no load_profile_power_w is given. |
| load_profile_interval_seconds | `Optional[int]` | `rw` | `None` | Duration of one 'load_profile_power_w' step in seconds. Defaults to the configured optimization interval when a profile is given. |
| load_profile_power_w | `Optional[list[float]]` | `rw` | `None` | Explicit load profile describing a single complete run as a sequence of non-negative power values in watts (e.g. [200.0, 2000.0, 1800.0, 100.0]). Each value covers 'load_profile_interval_seconds'. Mutually exclusive with consumption_wh/duration_h. |
| schedule_mode | `<enum 'ConsumerScheduleMode'>` | `rw` | `ONCE` | Scheduling mode: ONCE (a single run within the horizon) or DAILY (one run per local calendar day with a feasible full run). |
| time_windows | `Optional[akkudoktoreos.config.configabc.TimeWindowSequence]` | `rw` | `None` | Sequence of allowed time windows. Defaults to optimization general time window. |
| levelized_cost_of_storage_kwh | `float` | `rw` | `0.0` | Levelized cost of storage (LCOS), applied once to each kWh delivered by the battery [€/kWh]. |
| measurement_key_power_3_phase_sym_w | `str` | `ro` | `N/A` | Measurement key for the symmetric 3 phase power the battery is charged or discharged with [W]. |
| measurement_key_power_l1_w | `str` | `ro` | `N/A` | Measurement key for the L1 power the battery is charged or discharged with [W]. |
| measurement_key_power_l2_w | `str` | `ro` | `N/A` | Measurement key for the L2 power the battery is charged or discharged with [W]. |
| measurement_key_power_l3_w | `str` | `ro` | `N/A` | Measurement key for the L3 power the battery is charged or discharged with [W]. |
| measurement_key_soc_factor | `str` | `ro` | `N/A` | Measurement key for the battery state of charge (SoC) as factor of total capacity [0.0 ... 1.0]. |