"schema_version": "1.0",
"inverter_model": "Generic hybrid inverter",
"nominal_power_w": null,
"max_ac_charge_power_w": null,
"ac_charge_limits_total_charge": false,
"dc_to_ac_efficiency": {
"description": "Typical battery-to-AC efficiency of a hybrid inverter over the load fraction, not the datasheet of a specific model.",
"load_fraction": [0.05, 0.1, 0.2, 0.3, 0.5, 0.75, 1.0],
"efficiency": [0.88, 0.93, 0.955, 0.965, 0.97, 0.968, 0.965]
},
"ac_to_dc_efficiency": {
"description": "Typical AC-to-battery efficiency of a hybrid inverter over the load fraction, not the datasheet of a specific model.",
"load_fraction": [0.05, 0.1, 0.2, 0.3, 0.5, 0.75, 1.0],
"efficiency": [0.86, 0.92, 0.95, 0.96, 0.965, 0.963, 0.96]
},
"power_derating": {
"description": "Typical derating: full power up to 45 degC ambient, then linearly down to 60 % at 60 degC and to 0 at 65 degC.",
"temperature_degC": [-25.0, 45.0, 60.0, 65.0],
"power_fraction": [1.0, 1.0, 0.6, 0.0]
}
}