fix(genetic): plan the running slot only for the remaining time

A run within a slot (e.g. 10:45 with hourly slots) planned slot 0 as a
full slot, although the SoC is measured at the run time. Slot 0 now moves
only the remaining part of the slot energy: battery, EV and inverter
energy caps, SoC power limit tables and the slot's PV and load forecast
are scaled by first_slot_fraction; efficiency curves are read at the
power of that part. The plan's SoC headroom clamp of the AC charge factor
uses the same part, and the GENETIC result reports first_slot_fraction.
A run on a slot boundary is unchanged.

Additional changes
Pin GENETIC test start times to the full hour; their results now depend on seconds within the slot
Document first_slot_fraction for consumers of GENETIC results

Refs: #1543
Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
SchaafAlexander
2026-11-15 12:45:56 +01:00
committed by Bobby Noelte
co-authored by Claude Opus 5.5
parent 7e10f64048
commit 0bf9f50b97
15 changed files with 495 additions and 60 deletions
+5
View File
@@ -91,6 +91,11 @@ time, charging power and supported charge rates.
- Runtime forecast arrays start at local midnight and use the configured slot interval.
Energy is **Wh per slot**, not W or kWh. A constant 1,000 W load uses 250 Wh in 15 minutes.
- A run within a slot plans the first slot only for the time left in it, given as
`first_slot_fraction` in the GENETIC result (0.25 for a run at 10:45 with hourly
slots). The energies, costs and SoC change of that slot cover only that part, and its
charge/discharge factors are the power for the remaining time. A run on a slot
boundary plans a full first slot (`first_slot_fraction` 1.0).
- Runtime purchase and sale prices are **currency per Wh**: 0.30 EUR/kWh is 0.00030 EUR/Wh.
Provider power forecasts are converted by EOS; do not convert them a second time.
- Read returned timestamps and interval information instead of assuming 24 hourly values