fix(genetic): plan the running slot only for the remaining time

A run within a slot (e.g. 10:45 with hourly slots) planned slot 0 as a
full slot, although the SoC is measured at the run time. Slot 0 now moves
only the remaining part of the slot energy: battery, EV and inverter
energy caps, SoC power limit tables and the slot's PV and load forecast
are scaled by first_slot_fraction; efficiency curves are read at the
power of that part. The plan's SoC headroom clamp of the AC charge factor
uses the same part, and the GENETIC result reports first_slot_fraction.
A run on a slot boundary is unchanged.

Additional changes
Pin GENETIC test start times to the full hour; their results now depend on seconds within the slot
Document first_slot_fraction for consumers of GENETIC results

Refs: #1543
Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
SchaafAlexander
2026-11-15 12:45:56 +01:00
committed by Bobby Noelte
co-authored by Claude Opus 5.5
parent 7e10f64048
commit 0bf9f50b97
15 changed files with 495 additions and 60 deletions
+8
View File
@@ -11060,6 +11060,14 @@
"description": "Duration of one result/control slot in seconds.",
"default": 3600
},
"first_slot_fraction": {
"type": "number",
"maximum": 1.0,
"exclusiveMinimum": 0.0,
"title": "First Slot Fraction",
"description": "Part of the first control slot that was still ahead when the optimization ran (0.25 for a run at 10:45 with hourly slots). The results of the first slot cover only that part, and its factors are chosen for it. 1.0 for a run on a slot boundary.",
"default": 1.0
},
"eautocharge_hours_float": {
"anyOf": [
{