fix(genetic): plan the running slot only for the remaining time

A run within a slot (e.g. 10:45 with hourly slots) planned slot 0 as a
full slot, although the SoC is measured at the run time. Slot 0 now moves
only the remaining part of the slot energy: battery, EV and inverter
energy caps, SoC power limit tables and the slot's PV and load forecast
are scaled by first_slot_fraction; efficiency curves are read at the
power of that part. The plan's SoC headroom clamp of the AC charge factor
uses the same part, and the GENETIC result reports first_slot_fraction.
A run on a slot boundary is unchanged.

Additional changes
Pin GENETIC test start times to the full hour; their results now depend on seconds within the slot
Document first_slot_fraction for consumers of GENETIC results

Refs: #1543
Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
SchaafAlexander
2026-11-15 12:45:56 +01:00
committed by Bobby Noelte
co-authored by Claude Opus 5.5
parent 7e10f64048
commit 0bf9f50b97
15 changed files with 495 additions and 60 deletions
+5
View File
@@ -91,6 +91,11 @@ time, charging power and supported charge rates.
- Runtime forecast arrays start at local midnight and use the configured slot interval. - Runtime forecast arrays start at local midnight and use the configured slot interval.
Energy is **Wh per slot**, not W or kWh. A constant 1,000 W load uses 250 Wh in 15 minutes. Energy is **Wh per slot**, not W or kWh. A constant 1,000 W load uses 250 Wh in 15 minutes.
- A run within a slot plans the first slot only for the time left in it, given as
`first_slot_fraction` in the GENETIC result (0.25 for a run at 10:45 with hourly
slots). The energies, costs and SoC change of that slot cover only that part, and its
charge/discharge factors are the power for the remaining time. A run on a slot
boundary plans a full first slot (`first_slot_fraction` 1.0).
- Runtime purchase and sale prices are **currency per Wh**: 0.30 EUR/kWh is 0.00030 EUR/Wh. - Runtime purchase and sale prices are **currency per Wh**: 0.30 EUR/kWh is 0.00030 EUR/Wh.
Provider power forecasts are converted by EOS; do not convert them a second time. Provider power forecasts are converted by EOS; do not convert them a second time.
- Read returned timestamps and interval information instead of assuming 24 hourly values - Read returned timestamps and interval information instead of assuming 24 hourly values
+8
View File
@@ -11060,6 +11060,14 @@
"description": "Duration of one result/control slot in seconds.", "description": "Duration of one result/control slot in seconds.",
"default": 3600 "default": 3600
}, },
"first_slot_fraction": {
"type": "number",
"maximum": 1.0,
"exclusiveMinimum": 0.0,
"title": "First Slot Fraction",
"description": "Part of the first control slot that was still ahead when the optimization ran (0.25 for a run at 10:45 with hourly slots). The results of the first slot cover only that part, and its factors are chosen for it. 1.0 for a run on a slot boundary.",
"default": 1.0
},
"eautocharge_hours_float": { "eautocharge_hours_float": {
"anyOf": [ "anyOf": [
{ {
+59 -23
View File
@@ -406,17 +406,33 @@ class Battery:
parameters: BaseBatteryParameters, parameters: BaseBatteryParameters,
prediction_hours: int, prediction_hours: int,
slot_duration_h: float = 1.0, slot_duration_h: float = 1.0,
first_slot_fraction: float = 1.0,
): ):
# `prediction_hours` is the number of optimization slots, not hours. At # `prediction_hours` is the number of optimization slots, not hours. At
# the default optimization interval of 3600 s, slot_duration_h is 1.0 and # the default optimization interval of 3600 s, slot_duration_h is 1.0 and
# the slot count equals the hour count, so existing callers are # the slot count equals the hour count, so existing callers are
# unaffected. At 900 s (15 min) slot_duration_h is 0.25 and there are 4x # unaffected. At 900 s (15 min) slot_duration_h is 0.25 and there are 4x
# as many slots, each able to move a quarter of the hourly energy. # as many slots, each able to move a quarter of the hourly energy.
#
# `first_slot_fraction` is the part of slot 0 still ahead when the
# optimization runs within that slot (0.25 at 10:45 with hourly slots).
# Slot 0 then moves only that fraction of the slot energy; the slot's
# power limits and power dependent efficiencies stay the same.
if not 0.0 < first_slot_fraction <= 1.0:
raise ValueError(f"first_slot_fraction must be in (0, 1], got {first_slot_fraction}.")
self.parameters = parameters self.parameters = parameters
self.prediction_hours = prediction_hours self.prediction_hours = prediction_hours
self.slot_duration_h = slot_duration_h self.slot_duration_h = slot_duration_h
self.first_slot_fraction = first_slot_fraction
self._setup() self._setup()
def slot_scale(self, hour: int) -> float:
"""Return the part of the slot duration that is simulated for slot ``hour``.
``first_slot_fraction`` for slot 0, 1.0 for every later slot.
"""
return self.first_slot_fraction if hour == 0 else 1.0
def _setup(self) -> None: def _setup(self) -> None:
"""Sets up the battery parameters based on provided parameters.""" """Sets up the battery parameters based on provided parameters."""
self.capacity_wh = self.parameters.capacity_wh self.capacity_wh = self.parameters.capacity_wh
@@ -548,24 +564,30 @@ class Battery:
self._curves.reset(self.prediction_hours) self._curves.reset(self.prediction_hours)
self._charge_limit_raw_wh_per_slot = [float("inf")] * self.prediction_hours self._charge_limit_raw_wh_per_slot = [float("inf")] * self.prediction_hours
def _discharge_slot_cap_wh(self) -> float: def _discharge_slot_cap_wh(self, hour: int) -> float:
"""Return the raw discharge energy of one slot [Wh] at the current SoC.""" """Return the raw discharge energy of slot ``hour`` [Wh] at the current SoC."""
curves = self._curves curves = self._curves
if curves is None or curves.discharge_limit_wh_by_soc is None: if curves is None or curves.discharge_limit_wh_by_soc is None:
return self.max_discharge_power_w * self.slot_duration_h return self.max_discharge_power_w * self.slot_duration_h * self.slot_scale(hour)
return _table_entry( return _table_entry(
curves.discharge_limit_wh_by_soc, curves.discharge_limit_wh_by_soc,
int(self.soc_wh * curves.soc_index_per_wh + 0.5), int(self.soc_wh * curves.soc_index_per_wh + 0.5),
) ) * self.slot_scale(hour)
def _discharging_efficiency_at(self, slot_raw_wh: float) -> float: def _discharging_efficiency_at(self, slot_raw_wh: float, scale: float = 1.0) -> float:
"""Return the discharging efficiency at the slot power of ``slot_raw_wh``.""" """Return the discharging efficiency at the slot power of ``slot_raw_wh``.
Args:
slot_raw_wh: Raw discharge energy of the slot [Wh].
scale: Simulated part of the slot duration (see ``slot_scale``); the
power is the energy divided by that part of the slot.
"""
curves = self._curves curves = self._curves
if curves is None or curves.discharging_efficiency_by_power is None: if curves is None or curves.discharging_efficiency_by_power is None:
return self.discharging_efficiency return self.discharging_efficiency
return _table_entry( return _table_entry(
curves.discharging_efficiency_by_power, curves.discharging_efficiency_by_power,
int(slot_raw_wh * curves.discharge_index_per_wh + 0.5), int(slot_raw_wh / scale * curves.discharge_index_per_wh + 0.5),
) )
def limit_slot_charge(self, hour: int, raw_wh: float) -> None: def limit_slot_charge(self, hour: int, raw_wh: float) -> None:
@@ -582,24 +604,29 @@ class Battery:
self._charge_limit_raw_wh_per_slot[hour], max(float(raw_wh), 0.0) self._charge_limit_raw_wh_per_slot[hour], max(float(raw_wh), 0.0)
) )
def rated_discharge_energy_wh(self) -> float: def rated_discharge_energy_wh(self, hour: Optional[int] = None) -> float:
"""Return the DC energy one full-power discharge slot delivers. """Return the DC energy a full-power discharge delivers in one slot.
This is the reference a grid-export rate is applied to: a rate of 0.5 This is the reference a grid-export rate is applied to: a rate of 0.5
exports at most half the battery's rated discharge power, independent of exports at most half the battery's rated discharge power, independent of
how much of the slot budget self-consumption already used. how much of the slot budget self-consumption already used.
Args:
hour: Slot index. Slot 0 delivers only ``first_slot_fraction`` of
the slot energy. None gives a full slot.
""" """
rated_slot_wh = self.max_discharge_power_w * self.slot_duration_h scale = 1.0 if hour is None else self.slot_scale(hour)
return rated_slot_wh * self._discharging_efficiency_at(rated_slot_wh) rated_slot_wh = self.max_discharge_power_w * self.slot_duration_h * scale
return rated_slot_wh * self._discharging_efficiency_at(rated_slot_wh, scale)
def remaining_discharge_energy_wh(self, hour: int) -> float: def remaining_discharge_energy_wh(self, hour: int) -> float:
"""Return DC energy still deliverable within one optimization slot.""" """Return DC energy still deliverable within one optimization slot."""
discharged_raw_wh = self._discharged_raw_wh_per_slot[hour] discharged_raw_wh = self._discharged_raw_wh_per_slot[hour]
raw_power_remaining_wh = max(self._discharge_slot_cap_wh() - discharged_raw_wh, 0.0) raw_power_remaining_wh = max(self._discharge_slot_cap_wh(hour) - discharged_raw_wh, 0.0)
raw_soc_available_wh = max(self.soc_wh - self.min_soc_wh, 0.0) raw_soc_available_wh = max(self.soc_wh - self.min_soc_wh, 0.0)
raw_remaining_wh = min(raw_power_remaining_wh, raw_soc_available_wh) raw_remaining_wh = min(raw_power_remaining_wh, raw_soc_available_wh)
return raw_remaining_wh * self._discharging_efficiency_at( return raw_remaining_wh * self._discharging_efficiency_at(
discharged_raw_wh + raw_remaining_wh discharged_raw_wh + raw_remaining_wh, self.slot_scale(hour)
) )
def discharge_released(self, hour: int) -> bool: def discharge_released(self, hour: int) -> bool:
@@ -672,22 +699,26 @@ class Battery:
# Maximum raw discharge due to power limit, scaled to the slot duration. # Maximum raw discharge due to power limit, scaled to the slot duration.
# The power limit is a power [W]; energy movable in one slot is # The power limit is a power [W]; energy movable in one slot is
# power x slot_duration_h. With a battery profile the limit and the # power x slot_duration_h, and only the remaining part of slot 0 when
# efficiency are looked up inline (no calls): this runs for every slot # the optimization runs within it. With a battery profile the limit and
# of every candidate plan. # the efficiency are looked up inline (no calls): this runs for every
# slot of every candidate plan.
discharged_raw_wh = self._discharged_raw_wh_per_slot[hour] discharged_raw_wh = self._discharged_raw_wh_per_slot[hour]
discharging_efficiency = self.discharging_efficiency discharging_efficiency = self.discharging_efficiency
scale = self.first_slot_fraction if hour == 0 else 1.0
curves = self._curves curves = self._curves
if curves is None: if curves is None:
slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h * scale
raw_withdrawal_wh = min(raw_available_wh, max(slot_cap_wh - discharged_raw_wh, 0.0)) raw_withdrawal_wh = min(raw_available_wh, max(slot_cap_wh - discharged_raw_wh, 0.0))
else: else:
limits = curves.discharge_limit_wh_by_soc limits = curves.discharge_limit_wh_by_soc
if limits is None: if limits is None:
slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h * scale
else: else:
index = int(self.soc_wh * curves.soc_index_per_wh + 0.5) index = int(self.soc_wh * curves.soc_index_per_wh + 0.5)
slot_cap_wh = limits[index] if 0 <= index <= 100 else _table_entry(limits, index) slot_cap_wh = (
limits[index] if 0 <= index <= 100 else _table_entry(limits, index)
) * scale
raw_withdrawal_wh = slot_cap_wh - discharged_raw_wh raw_withdrawal_wh = slot_cap_wh - discharged_raw_wh
if raw_withdrawal_wh < 0.0: if raw_withdrawal_wh < 0.0:
raw_withdrawal_wh = 0.0 raw_withdrawal_wh = 0.0
@@ -702,7 +733,8 @@ class Battery:
if raw_estimate_wh > raw_withdrawal_wh: if raw_estimate_wh > raw_withdrawal_wh:
raw_estimate_wh = raw_withdrawal_wh raw_estimate_wh = raw_withdrawal_wh
index = int( index = int(
(discharged_raw_wh + raw_estimate_wh) * curves.discharge_index_per_wh + 0.5 (discharged_raw_wh + raw_estimate_wh) / scale * curves.discharge_index_per_wh
+ 0.5
) )
discharging_efficiency = efficiencies[index] if index <= 100 else efficiencies[-1] discharging_efficiency = efficiencies[index] if index <= 100 else efficiencies[-1]
@@ -804,9 +836,11 @@ class Battery:
charged_raw_wh = self._charged_raw_wh_per_slot[hour] charged_raw_wh = self._charged_raw_wh_per_slot[hour]
# Scale the power cap [W] to a per-slot energy cap [Wh] (W x slot hours). # Scale the power cap [W] to a per-slot energy cap [Wh] (W x slot hours).
# At slot_duration_h=1.0 (hourly) this equals the legacy power value. # At slot_duration_h=1.0 (hourly) this equals the legacy power value.
# Slot 0 only has its remaining part when the run starts within it.
scale = self.first_slot_fraction if hour == 0 else 1.0
max_charge_per_slot_wh_fast = max( max_charge_per_slot_wh_fast = max(
min( min(
self.max_charge_power_w * self.slot_duration_h, self.max_charge_power_w * self.slot_duration_h * scale,
self._charge_limit_raw_wh_per_slot[hour], self._charge_limit_raw_wh_per_slot[hour],
) )
- charged_raw_wh, - charged_raw_wh,
@@ -824,7 +858,7 @@ class Battery:
index = int(soc_wh_fast * curves.soc_index_per_wh + 0.5) index = int(soc_wh_fast * curves.soc_index_per_wh + 0.5)
soc_limit_raw_wh = ( soc_limit_raw_wh = (
limits[index] if 0 <= index <= 100 else _table_entry(limits, index) limits[index] if 0 <= index <= 100 else _table_entry(limits, index)
) - charged_raw_wh ) * scale - charged_raw_wh
if soc_limit_raw_wh < 0.0: if soc_limit_raw_wh < 0.0:
soc_limit_raw_wh = 0.0 soc_limit_raw_wh = 0.0
efficiencies = curves.charging_efficiency_by_power efficiencies = curves.charging_efficiency_by_power
@@ -840,7 +874,9 @@ class Battery:
intended_raw_wh = soc_limit_raw_wh intended_raw_wh = soc_limit_raw_wh
if intended_raw_wh < 0.0: if intended_raw_wh < 0.0:
intended_raw_wh = 0.0 intended_raw_wh = 0.0
index = int((charged_raw_wh + intended_raw_wh) * curves.charge_index_per_wh + 0.5) index = int(
(charged_raw_wh + intended_raw_wh) / scale * curves.charge_index_per_wh + 0.5
)
charging_efficiency_fast = efficiencies[index] if index <= 100 else efficiencies[-1] charging_efficiency_fast = efficiencies[index] if index <= 100 else efficiencies[-1]
# Decide mode & determine raw_request_wh and raw_charge_wh # Decide mode & determine raw_request_wh and raw_charge_wh
+54 -20
View File
@@ -137,12 +137,26 @@ class Inverter:
parameters: InverterParameters, parameters: InverterParameters,
battery: Optional[Battery] = None, battery: Optional[Battery] = None,
slot_duration_h: float = 1.0, slot_duration_h: float = 1.0,
first_slot_fraction: float = 1.0,
): ):
# `first_slot_fraction` is the part of slot 0 still ahead when the
# optimization runs within that slot; slot 0 then moves only that part
# of the slot energy (see Battery).
if not 0.0 < first_slot_fraction <= 1.0:
raise ValueError(f"first_slot_fraction must be in (0, 1], got {first_slot_fraction}.")
self.parameters: InverterParameters = parameters self.parameters: InverterParameters = parameters
self.battery: Optional[Battery] = battery self.battery: Optional[Battery] = battery
self.slot_duration_h: float = slot_duration_h self.slot_duration_h: float = slot_duration_h
self.first_slot_fraction: float = first_slot_fraction
self._setup() self._setup()
def slot_scale(self, hour: int) -> float:
"""Return the part of the slot duration that is simulated for slot ``hour``.
``first_slot_fraction`` for slot 0, 1.0 for every later slot.
"""
return self.first_slot_fraction if hour == 0 else 1.0
def _setup(self) -> None: def _setup(self) -> None:
if self.battery and self.parameters.battery_id != self.battery.parameters.device_id: if self.battery and self.parameters.battery_id != self.battery.parameters.device_id:
error_msg = f"Battery ID mismatch - {self.parameters.battery_id} is configured; got {self.battery.parameters.device_id}." error_msg = f"Battery ID mismatch - {self.parameters.battery_id} is configured; got {self.battery.parameters.device_id}."
@@ -167,19 +181,24 @@ class Inverter:
self.max_ac_charge_power_w = self.parameters.max_ac_charge_power_w self.max_ac_charge_power_w = self.parameters.max_ac_charge_power_w
self.ac_charge_limits_total_charge = self.parameters.ac_charge_limits_total_charge self.ac_charge_limits_total_charge = self.parameters.ac_charge_limits_total_charge
def dc_to_ac_efficiency_at(self, ac_wh: float) -> float: def dc_to_ac_efficiency_at(self, ac_wh: float, scale: float = 1.0) -> float:
"""Return the DC-to-AC efficiency of a conversion delivering ``ac_wh`` in one slot. """Return the DC-to-AC efficiency of a conversion delivering ``ac_wh`` in one slot.
Without ``dc_to_ac_efficiency_curve`` this is the constant Without ``dc_to_ac_efficiency_curve`` this is the constant
``dc_to_ac_efficiency``. With a curve, the efficiency is interpolated at ``dc_to_ac_efficiency``. With a curve, the efficiency is interpolated at
the load fraction ``ac_wh / max_power_wh`` of this slot. ``max_power_wh`` the load fraction ``ac_wh / (max_power_wh * scale)`` of this slot.
is already scaled to the slot duration, so the fraction equals the mean ``max_power_wh`` is already scaled to the slot duration, so the fraction
AC power relative to the rated power. equals the mean AC power relative to the rated power.
Args:
ac_wh: AC energy of the conversion in this slot [Wh].
scale: Simulated part of the slot duration (see ``slot_scale``).
""" """
if self.dc_to_ac_efficiency_curve is None: if self.dc_to_ac_efficiency_curve is None:
return self.dc_to_ac_efficiency return self.dc_to_ac_efficiency
curve: list[tuple[float, float]] = self.dc_to_ac_efficiency_curve curve: list[tuple[float, float]] = self.dc_to_ac_efficiency_curve
load_fraction = ac_wh / self.max_power_wh if self.max_power_wh > 0 else 0.0 slot_max_power_wh = self.max_power_wh * scale
load_fraction = ac_wh / slot_max_power_wh if slot_max_power_wh > 0 else 0.0
# This runs for every battery discharge of every candidate plan. Find # This runs for every battery discharge of every candidate plan. Find
# the curve segment by bisection on the load fractions, split off once # the curve segment by bisection on the load fractions, split off once
# per curve, instead of walking the points. The segment and the # per curve, instead of walking the points. The segment and the
@@ -234,7 +253,11 @@ class Inverter:
""" """
if self.ac_charge_limits_total_charge and self.battery and factor > 0.0: if self.ac_charge_limits_total_charge and self.battery and factor > 0.0:
self.battery.limit_slot_charge( self.battery.limit_slot_charge(
hour, self.battery.max_charge_power_w * self.slot_duration_h * factor hour,
self.battery.max_charge_power_w
* self.slot_duration_h
* self.slot_scale(hour)
* factor,
) )
def charge_battery_from_grid(self, hour: int, factor: float) -> tuple[float, float]: def charge_battery_from_grid(self, hour: int, factor: float) -> tuple[float, float]:
@@ -250,9 +273,10 @@ class Inverter:
""" """
if not self.battery or factor <= 0.0: if not self.battery or factor <= 0.0:
return 0.0, 0.0 return 0.0, 0.0
scale = self.slot_scale(hour)
if self.ac_charge_limits_total_charge: if self.ac_charge_limits_total_charge:
stored, battery_losses = self.battery.charge_energy( stored, battery_losses = self.battery.charge_energy(
self.battery.max_charge_power_w * self.slot_duration_h * factor, hour self.battery.max_charge_power_w * self.slot_duration_h * scale * factor, hour
) )
else: else:
stored, battery_losses = self.battery.charge_energy(None, hour, charge_factor=factor) stored, battery_losses = self.battery.charge_energy(None, hour, charge_factor=factor)
@@ -262,7 +286,7 @@ class Inverter:
# curve the efficiency is the one at the AC load actually drawn. # curve the efficiency is the one at the AC load actually drawn.
curve = self.ac_to_dc_efficiency_curve curve = self.ac_to_dc_efficiency_curve
if curve is not None: if curve is not None:
ac_energy = solve_ac_for_charge_dc_energy(curve, dc_energy, self.max_power_wh) ac_energy = solve_ac_for_charge_dc_energy(curve, dc_energy, self.max_power_wh * scale)
else: else:
ac_energy = dc_energy / self.ac_to_dc_efficiency ac_energy = dc_energy / self.ac_to_dc_efficiency
return ac_energy, battery_losses + (ac_energy - dc_energy) return ac_energy, battery_losses + (ac_energy - dc_energy)
@@ -273,18 +297,20 @@ class Inverter:
dc_request: float, dc_request: float,
requested_ac_wh: float, requested_ac_wh: float,
dc_to_ac_efficiency: float, dc_to_ac_efficiency: float,
scale: float = 1.0,
) -> float: ) -> float:
"""Return the AC energy of a discharge that delivered ``battery_discharge_dc``. """Return the AC energy of a discharge that delivered ``battery_discharge_dc``.
If the battery delivered less than requested (low state of charge or its If the battery delivered less than requested (low state of charge or its
power limit), the conversion runs at a lower AC load than requested. With power limit), the conversion runs at a lower AC load than requested. With
an efficiency curve the efficiency must then be the one at the AC energy an efficiency curve the efficiency must then be the one at the AC energy
that is actually delivered, not at the request. that is actually delivered, not at the request. ``scale`` is the
simulated part of the slot duration (see ``slot_scale``).
""" """
curve = self.dc_to_ac_efficiency_curve curve = self.dc_to_ac_efficiency_curve
if curve is not None and battery_discharge_dc < dc_request * (1.0 - 1e-12): if curve is not None and battery_discharge_dc < dc_request * (1.0 - 1e-12):
return solve_ac_for_dc_energy( return solve_ac_for_dc_energy(
curve, battery_discharge_dc, self.max_power_wh, requested_ac_wh curve, battery_discharge_dc, self.max_power_wh * scale, requested_ac_wh
) )
return battery_discharge_dc * dc_to_ac_efficiency return battery_discharge_dc * dc_to_ac_efficiency
@@ -293,15 +319,16 @@ class Inverter:
battery = self.battery battery = self.battery
if not battery or requested_ac_wh <= 0.0: if not battery or requested_ac_wh <= 0.0:
return 0.0, 0.0 return 0.0, 0.0
scale = self.first_slot_fraction if hour == 0 else 1.0
if type(battery) is not Battery: if type(battery) is not Battery:
# Another battery implementation: ask it, step by step. # Another battery implementation: ask it, step by step.
if not battery.discharge_released(hour): if not battery.discharge_released(hour):
return 0.0, 0.0 return 0.0, 0.0
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh) dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh, scale)
dc_request = requested_ac_wh / dc_to_ac_efficiency dc_request = requested_ac_wh / dc_to_ac_efficiency
battery_discharge_dc, discharge_losses = battery.discharge_energy(dc_request, hour) battery_discharge_dc, discharge_losses = battery.discharge_energy(dc_request, hour)
battery_discharge_ac = self._delivered_ac_wh( battery_discharge_ac = self._delivered_ac_wh(
battery_discharge_dc, dc_request, requested_ac_wh, dc_to_ac_efficiency battery_discharge_dc, dc_request, requested_ac_wh, dc_to_ac_efficiency, scale
) )
inverter_discharge_losses = battery_discharge_dc - battery_discharge_ac inverter_discharge_losses = battery_discharge_dc - battery_discharge_ac
return battery_discharge_ac, discharge_losses + inverter_discharge_losses return battery_discharge_ac, discharge_losses + inverter_discharge_losses
@@ -319,7 +346,7 @@ class Inverter:
if self.dc_to_ac_efficiency_curve is None: if self.dc_to_ac_efficiency_curve is None:
dc_to_ac_efficiency = self.dc_to_ac_efficiency dc_to_ac_efficiency = self.dc_to_ac_efficiency
else: else:
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh) dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh, scale)
dc_request = requested_ac_wh / dc_to_ac_efficiency dc_request = requested_ac_wh / dc_to_ac_efficiency
if battery._curves is not None: if battery._curves is not None:
@@ -335,7 +362,10 @@ class Inverter:
# Match Battery.discharge_energy(): preserve a SoC below the reserve. # Match Battery.discharge_energy(): preserve a SoC below the reserve.
return 0.0, 0.0 return 0.0, 0.0
max_raw_wh = max( max_raw_wh = max(
battery.max_discharge_power_w * battery.slot_duration_h - discharged_raw_wh[hour], battery.max_discharge_power_w
* battery.slot_duration_h
* (battery.first_slot_fraction if hour == 0 else 1.0)
- discharged_raw_wh[hour],
0.0, 0.0,
) )
max_deliverable_wh = min(raw_available_wh, max_raw_wh) * discharging_efficiency max_deliverable_wh = min(raw_available_wh, max_raw_wh) * discharging_efficiency
@@ -354,7 +384,7 @@ class Inverter:
battery_discharge_ac = solve_ac_for_dc_energy( battery_discharge_ac = solve_ac_for_dc_energy(
self.dc_to_ac_efficiency_curve, self.dc_to_ac_efficiency_curve,
battery_discharge_dc, battery_discharge_dc,
self.max_power_wh, self.max_power_wh * scale,
requested_ac_wh, requested_ac_wh,
) )
else: else:
@@ -402,12 +432,16 @@ class Inverter:
if consumption < 0.0: if consumption < 0.0:
consumption = 0.0 consumption = 0.0
battery = self.battery battery = self.battery
max_power_wh = self.max_power_wh # Slot 0 only has its remaining part when the run starts within it:
# the inverter moves that part of the slot energy, and the slot's
# energies are converted to power over that part of the slot.
scale = self.first_slot_fraction if hour == 0 else 1.0
max_power_wh = self.max_power_wh * scale
# Convert interval energy [Wh] to mean power [W] for the probability # Convert interval energy [Wh] to mean power [W] for the probability
# lookup, then convert its expected direct power back to slot energy. # lookup, then convert its expected direct power back to slot energy.
if generation > 0.0 and consumption > 0.0: if generation > 0.0 and consumption > 0.0:
slot_duration_h = self.slot_duration_h slot_duration_h = self.slot_duration_h * scale
expected_direct_power_w = ( expected_direct_power_w = (
self.self_consumption_predictor.calculate_expected_direct_consumption( self.self_consumption_predictor.calculate_expected_direct_consumption(
consumption / slot_duration_h, consumption / slot_duration_h,
@@ -504,14 +538,14 @@ class Inverter:
# limited by the energy the battery can actually deliver. # limited by the energy the battery can actually deliver.
remaining_battery_dc = battery.remaining_discharge_energy_wh(hour) remaining_battery_dc = battery.remaining_discharge_energy_wh(hour)
remaining_battery_ac = remaining_battery_dc * self.dc_to_ac_efficiency_at( remaining_battery_ac = remaining_battery_dc * self.dc_to_ac_efficiency_at(
remaining_battery_dc remaining_battery_dc, scale
) )
# The rate caps the export against the battery's *rated* discharge # The rate caps the export against the battery's *rated* discharge
# power, so it stays a plain power setpoint ("export at 50 %") that # power, so it stays a plain power setpoint ("export at 50 %") that
# does not silently grow when self-consumption used less of the slot. # does not silently grow when self-consumption used less of the slot.
# At factor 1.0 this bound never binds; behaviour is unchanged. # At factor 1.0 this bound never binds; behaviour is unchanged.
rated_export_dc = battery.rated_discharge_energy_wh() * export_factor rated_export_dc = battery.rated_discharge_energy_wh(hour) * export_factor
rated_export_ac = rated_export_dc * self.dc_to_ac_efficiency_at(rated_export_dc) rated_export_ac = rated_export_dc * self.dc_to_ac_efficiency_at(rated_export_dc, scale)
export_capacity = remaining_inverter_ac_capacity export_capacity = remaining_inverter_ac_capacity
if remaining_battery_ac < export_capacity: if remaining_battery_ac < export_capacity:
export_capacity = remaining_battery_ac export_capacity = remaining_battery_ac
@@ -1056,6 +1056,37 @@ class GeneticOptimization(OptimizationBase):
"""Genomes and device arrays start at now, independently of wall-clock hour.""" """Genomes and device arrays start at now, independently of wall-clock hour."""
return 0 return 0
def _remaining_first_slot_fraction(self) -> float:
"""Return the part of slot 0 that is still ahead of the run.
The run start is rounded down to the slot (``ems.start_datetime``),
while the measurements and the plan apply from the unrounded run time
(``ems.observation_datetime``). A run at 10:45 with hourly slots has
a quarter of slot 0 left. A run on a slot boundary, or without a
usable run time, keeps the full slot (1.0).
"""
slot_seconds = self.slot_duration_h * 3600
slot0 = self.ems.start_datetime
observed = self.ems.observation_datetime
elapsed_s = (observed - slot0).total_seconds()
if elapsed_s <= 0.0:
return 1.0
if elapsed_s >= slot_seconds:
logger.debug(
"Run time {} is not within slot 0 starting {}; planning a full first slot.",
observed,
slot0,
)
return 1.0
fraction = (slot_seconds - elapsed_s) / slot_seconds
logger.debug(
"Run at {} within slot 0 starting {}: {:.3f} of slot 0 left.",
observed,
slot0,
fraction,
)
return fraction
def _start_day_slot(self) -> int: def _start_day_slot(self) -> int:
"""Offset used only to trim legacy midnight-indexed forecast inputs.""" """Offset used only to trim legacy midnight-indexed forecast inputs."""
sd = self.ems.start_datetime sd = self.ems.start_datetime
@@ -1085,6 +1116,9 @@ class GeneticOptimization(OptimizationBase):
# Populated from parameters.pv_battery.grid_export_rates in optimize_ems; # Populated from parameters.pv_battery.grid_export_rates in optimize_ems;
# the single full-power default keeps the all-or-nothing export. # the single full-power default keeps the all-or-nothing export.
self.bat_possible_grid_export_values: list[float] = [1.0] self.bat_possible_grid_export_values: list[float] = [1.0]
# Part of slot 0 still ahead of the run (1.0 on a slot boundary), set
# per run by optimize_ems().
self.first_slot_fraction: float = 1.0
# Slot by which the EV has to reach its target SoC. None means the SoC is # Slot by which the EV has to reach its target SoC. None means the SoC is
# only required at the end of the horizon (the behaviour without a deadline). # only required at the end of the horizon (the behaviour without a deadline).
self._ev_soc_deadline_slot: Optional[int] = None self._ev_soc_deadline_slot: Optional[int] = None
@@ -2524,15 +2558,18 @@ class GeneticOptimization(OptimizationBase):
return schedule return schedule
max_stored_wh = ev.max_charge_power_w * self.slot_duration_h * ev.charging_efficiency max_stored_wh = ev.max_charge_power_w * self.slot_duration_h * ev.charging_efficiency
first_slot_fraction = getattr(self, "first_slot_fraction", 1.0)
remaining_wh = required_stored_wh remaining_wh = required_stored_wh
for slot in candidates: for slot in candidates:
required_rate = remaining_wh / max(max_stored_wh, 1e-9) # Slot 0 only has its remaining part when the run starts within it.
slot_stored_wh = max_stored_wh * (first_slot_fraction if slot == 0 else 1.0)
required_rate = remaining_wh / max(slot_stored_wh, 1e-9)
rate, rate_index = next( rate, rate_index = next(
(item for item in positive_rates if item[0] >= required_rate), (item for item in positive_rates if item[0] >= required_rate),
positive_rates[-1], positive_rates[-1],
) )
schedule[slot] = rate_index schedule[slot] = rate_index
remaining_wh -= max_stored_wh * rate remaining_wh -= slot_stored_wh * rate
if remaining_wh <= 1e-9: if remaining_wh <= 1e-9:
break break
return schedule return schedule
@@ -3856,8 +3893,12 @@ class GeneticOptimization(OptimizationBase):
# AC charging at this hour is economically unjustified. # AC charging at this hour is economically unjustified.
# Penalty = excess cost per Wh × DC energy requested this slot. # Penalty = excess cost per Wh × DC energy requested this slot.
# max_charge_power_w is a power [W]; the energy movable in # max_charge_power_w is a power [W]; the energy movable in
# one slot is power × slot_duration_h (¼ at 15 min). # one slot is power × slot_duration_h (¼ at 15 min), and
dc_wh = bat.max_charge_power_w * self.slot_duration_h * ac_factor # only the remaining part of slot 0 within that slot.
slot_scale = getattr(self, "first_slot_fraction", 1.0) if hour == 0 else 1.0
dc_wh = (
bat.max_charge_power_w * self.slot_duration_h * slot_scale * ac_factor
)
ac_wh = dc_wh / max(inv.ac_to_dc_efficiency, 1e-9) ac_wh = dc_wh / max(inv.ac_to_dc_efficiency, 1e-9)
excess_cost_per_wh = break_even_price - best_uncovered_price excess_cost_per_wh = break_even_price - best_uncovered_price
gesamtbilanz += ac_wh * excess_cost_per_wh * ac_penalty_factor gesamtbilanz += ac_wh * excess_cost_per_wh * ac_penalty_factor
@@ -4215,6 +4256,9 @@ class GeneticOptimization(OptimizationBase):
# break-even lookup must be rebuilt lazily on first evaluation. # break-even lookup must be rebuilt lazily on first evaluation.
self._ac_break_even_best_prices = None self._ac_break_even_best_prices = None
# A run within a slot plans slot 0 for the remaining time only.
self.first_slot_fraction = self._remaining_first_slot_fraction()
# Initialize PV and EV batteries. slot_duration_h lets the Battery scale # Initialize PV and EV batteries. slot_duration_h lets the Battery scale
# its power caps (max_charge_power_w) to a per-slot energy cap. # its power caps (max_charge_power_w) to a per-slot energy cap.
akku: Optional[Battery] = None akku: Optional[Battery] = None
@@ -4223,6 +4267,7 @@ class GeneticOptimization(OptimizationBase):
parameters.pv_battery, parameters.pv_battery,
prediction_hours=self.control_end_slot, prediction_hours=self.control_end_slot,
slot_duration_h=self.slot_duration_h, slot_duration_h=self.slot_duration_h,
first_slot_fraction=self.first_slot_fraction,
) )
akku.set_charge_per_hour(np.full(self.control_end_slot, 0)) akku.set_charge_per_hour(np.full(self.control_end_slot, 0))
@@ -4232,6 +4277,7 @@ class GeneticOptimization(OptimizationBase):
parameters.ev, parameters.ev,
prediction_hours=self.control_end_slot, prediction_hours=self.control_end_slot,
slot_duration_h=self.slot_duration_h, slot_duration_h=self.slot_duration_h,
first_slot_fraction=self.first_slot_fraction,
) )
eauto.set_charge_per_hour(np.full(self.control_end_slot, 1)) eauto.set_charge_per_hour(np.full(self.control_end_slot, 1))
self.optimize_ev = ( self.optimize_ev = (
@@ -4356,6 +4402,7 @@ class GeneticOptimization(OptimizationBase):
parameters.inverter, parameters.inverter,
battery=akku, battery=akku,
slot_duration_h=self.slot_duration_h, slot_duration_h=self.slot_duration_h,
first_slot_fraction=self.first_slot_fraction,
) )
# Prepare device simulation # Prepare device simulation
@@ -4386,6 +4433,16 @@ class GeneticOptimization(OptimizationBase):
"elect_revenue_per_hour_arr", "elect_revenue_per_hour_arr",
): ):
setattr(self.simulation, name, getattr(self.simulation, name)[: self.control_slots]) setattr(self.simulation, name, getattr(self.simulation, name)[: self.control_slots])
# Only the remaining part of slot 0 is ahead: its PV and load forecast
# shrink to that part (spread evenly over the slot). Prices are per Wh
# and stay. The terminal value curve above keeps the full forecasts.
if self.first_slot_fraction < 1.0:
for name in ("load_energy_array", "pv_prediction_wh"):
values = getattr(self.simulation, name)
if values is not None and len(values) > 0:
values = np.array(values, dtype=float)
values[0] *= self.first_slot_fraction
setattr(self.simulation, name, values)
# Setup the DEAP environment and optimization process. The appliance # Setup the DEAP environment and optimization process. The appliance
# genome layout (built above) drives the appliance gene block; evaluate # genome layout (built above) drives the appliance gene block; evaluate
@@ -4481,6 +4538,7 @@ class GeneticOptimization(OptimizationBase):
**{ **{
"parameters": parameters, "parameters": parameters,
"interval_seconds": self._genetic_cfg.interval_sec, "interval_seconds": self._genetic_cfg.interval_sec,
"first_slot_fraction": self.first_slot_fraction,
"start_hour": start_hour, "start_hour": start_hour,
"extra_data": extra_data, "extra_data": extra_data,
"fitness_history": self.fitness_history, "fitness_history": self.fitness_history,
@@ -474,6 +474,18 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
default=3600, description="Duration of one result/control slot in seconds." default=3600, description="Duration of one result/control slot in seconds."
) )
first_slot_fraction: float = Field(
default=1.0,
gt=0.0,
le=1.0,
description=(
"Part of the first control slot that was still ahead when the "
"optimization ran (0.25 for a run at 10:45 with hourly slots). The "
"results of the first slot cover only that part, and its factors are "
"chosen for it. 1.0 for a run on a slot boundary."
),
)
@field_validator("start_solution_datetime", mode="before") @field_validator("start_solution_datetime", mode="before")
@classmethod @classmethod
def transform_start_solution_datetime(cls, value: Any) -> Optional[DateTime]: def transform_start_solution_datetime(cls, value: Any) -> Optional[DateTime]:
@@ -621,6 +633,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
discharge_allowed: bool, discharge_allowed: bool,
soc_pct: float, soc_pct: float,
battery_grid_export_allowed: bool = False, battery_grid_export_allowed: bool = False,
slot_fraction: float = 1.0,
) -> tuple[float, float, bool, bool]: ) -> tuple[float, float, bool, bool]:
"""Clamp raw genetic gene values by the battery's actual SOC at that hour. """Clamp raw genetic gene values by the battery's actual SOC at that hour.
@@ -638,6 +651,10 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
(the inverter curtails automatically, but this makes intent clear). (the inverter curtails automatically, but this makes intent clear).
- Discharge: blocked when SOC is at or below min SOC. - Discharge: blocked when SOC is at or below min SOC.
- Battery grid export: blocked when SOC is at or below min SOC. - Battery grid export: blocked when SOC is at or below min SOC.
``slot_fraction`` is the part of the slot the factors apply to:
``first_slot_fraction`` for the running first slot, else 1.0. The
headroom check of the AC charge factor uses only that part of the slot.
""" """
parameters = getattr(self, "parameters", None) parameters = getattr(self, "parameters", None)
# Without parameters, convert the battery settings: they hold no # Without parameters, convert the battery settings: they hold no
@@ -679,7 +696,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
) )
# Energy storable in one optimization slot, not per hour: scale the # Energy storable in one optimization slot, not per hour: scale the
# power [W] by the slot duration (1.0 hourly, 0.25 at 15 min). # power [W] by the slot duration (1.0 hourly, 0.25 at 15 min).
slot_duration_h = float(self.interval_seconds) / 3600.0 slot_duration_h = float(self.interval_seconds) / 3600.0 * slot_fraction
max_dc_per_slot_wh = ( max_dc_per_slot_wh = (
effective_ac * max_ac_cp_w * slot_duration_h * ac_to_dc_eff * ch_eff effective_ac * max_ac_cp_w * slot_duration_h * ac_to_dc_eff * ch_eff
) )
@@ -821,6 +838,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
discharge_allowed_hour, discharge_allowed_hour,
soc_h_pct, soc_h_pct,
battery_grid_export_allowed_hour, battery_grid_export_allowed_hour,
self.first_slot_fraction if result_idx == 0 else 1.0,
) )
operation_mode, operation_mode_factor = self._battery_operation_from_solution( operation_mode, operation_mode_factor = self._battery_operation_from_solution(
eff_ac, eff_dc, eff_dis, eff_grid_export, battery_grid_export_factor_hour eff_ac, eff_dc, eff_dis, eff_grid_export, battery_grid_export_factor_hour
@@ -1097,6 +1115,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
bool(self.discharge_allowed[hour_idx]), bool(self.discharge_allowed[hour_idx]),
soc_h_pct, soc_h_pct,
battery_grid_export_allowed_hour, battery_grid_export_allowed_hour,
self.first_slot_fraction if result_idx == 0 else 1.0,
) )
operation_mode, operation_mode_factor = self._battery_operation_from_solution( operation_mode, operation_mode_factor = self._battery_operation_from_solution(
eff_ac, eff_ac,
+85
View File
@@ -760,3 +760,88 @@ class TestPowerCurves:
def test_invalid_curves_are_rejected(self, field, value): def test_invalid_curves_are_rejected(self, field, value):
with pytest.raises(ValidationError): with pytest.raises(ValidationError):
SolarPanelBatteryParameters(device_id="battery1", capacity_wh=10_000, **{field: value}) SolarPanelBatteryParameters(device_id="battery1", capacity_wh=10_000, **{field: value})
class TestFirstSlotFraction:
"""A run within slot 0 simulates only the remaining part of that slot."""
@staticmethod
def _battery(first_slot_fraction=1.0, soc=50, **curves):
params = SolarPanelBatteryParameters(
device_id="battery1",
capacity_wh=40_000,
initial_soc_percentage=soc,
min_soc_percentage=0,
max_soc_percentage=100,
max_charge_power_w=8_000,
max_discharge_power_w=4_000,
charging_efficiency=1.0,
discharging_efficiency=1.0,
**curves,
)
battery = Battery(
params, prediction_hours=4, slot_duration_h=1.0, first_slot_fraction=first_slot_fraction
)
battery.set_charge_per_hour(np.ones(4))
battery.set_discharge_per_hour(np.ones(4))
return battery
def test_slot_0_charges_only_the_remaining_part(self):
battery = self._battery(first_slot_fraction=0.25)
stored, _ = battery.charge_energy(None, 0, charge_factor=1.0)
assert stored == pytest.approx(2_000.0)
# Mode 1 (a PV surplus) is capped the same way.
assert battery.charge_energy(5_000.0, 0) == pytest.approx((0.0, 0.0))
# Slot 1 is a full slot again.
stored, _ = battery.charge_energy(None, 1, charge_factor=1.0)
assert stored == pytest.approx(8_000.0)
def test_slot_0_discharges_only_the_remaining_part(self):
battery = self._battery(first_slot_fraction=0.25)
assert battery.remaining_discharge_energy_wh(0) == pytest.approx(1_000.0)
assert battery.rated_discharge_energy_wh(0) == pytest.approx(1_000.0)
assert battery.rated_discharge_energy_wh(1) == pytest.approx(4_000.0)
assert battery.rated_discharge_energy_wh() == pytest.approx(4_000.0)
delivered, _ = battery.discharge_energy(9_000.0, 0)
assert delivered == pytest.approx(1_000.0)
delivered, _ = battery.discharge_energy(9_000.0, 1)
assert delivered == pytest.approx(4_000.0)
def test_full_fraction_is_the_plain_slot(self):
partial = self._battery(first_slot_fraction=1.0)
plain = Battery(partial.parameters, prediction_hours=4, slot_duration_h=1.0)
plain.set_charge_per_hour(np.ones(4))
assert partial.charge_energy(None, 0, charge_factor=1.0) == plain.charge_energy(
None, 0, charge_factor=1.0
)
def test_soc_power_limit_scales_with_the_remaining_part(self):
battery = self._battery(
first_slot_fraction=0.5,
charge_power_limit_w_by_soc=[6_000.0] * 101,
discharge_power_limit_w_by_soc=[2_000.0] * 101,
)
stored, _ = battery.charge_energy(None, 0, charge_factor=1.0)
assert stored == pytest.approx(3_000.0)
delivered, _ = battery.discharge_energy(9_000.0, 0)
assert delivered == pytest.approx(1_000.0)
def test_efficiency_curve_is_read_at_the_power_not_the_energy(self):
"""Full power for 15 min has the efficiency of full power, not of 25 %."""
curve = [(0.0, 0.95), (0.25, 0.95), (1.0, 0.80)]
battery = self._battery(
first_slot_fraction=0.25,
charging_efficiency_curve=curve,
discharging_efficiency_curve=curve,
)
stored, losses = battery.charge_energy(None, 0, charge_factor=1.0)
assert stored + losses == pytest.approx(2_000.0)
assert stored == pytest.approx(2_000.0 * 0.80)
delivered, losses = battery.discharge_energy(9_000.0, 0)
assert delivered + losses == pytest.approx(1_000.0)
assert delivered == pytest.approx(1_000.0 * 0.80)
@pytest.mark.parametrize("fraction", [0.0, -0.1, 1.5])
def test_invalid_fraction_is_rejected(self, fraction):
with pytest.raises(ValueError, match="first_slot_fraction"):
self._battery(first_slot_fraction=fraction)
+3 -3
View File
@@ -510,7 +510,7 @@ def _full_charge_parameters(hours: int, **battery_extra) -> GeneticOptimizationP
def test_full_charge_slot_resolution(config_eos: ConfigEOS): def test_full_charge_slot_resolution(config_eos: ConfigEOS):
_optimizer_config(config_eos, 24) _optimizer_config(config_eos, 24)
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
optimization = GeneticOptimization(fixed_seed=1) optimization = GeneticOptimization(fixed_seed=1)
optimization._slot0_datetime = optimization.ems.start_datetime optimization._slot0_datetime = optimization.ems.start_datetime
slot0 = optimization._slot0_datetime slot0 = optimization._slot0_datetime
@@ -530,7 +530,7 @@ def test_full_charge_slot_resolution(config_eos: ConfigEOS):
def test_maximum_soc_before_deadline_counts(config_eos: ConfigEOS): def test_maximum_soc_before_deadline_counts(config_eos: ConfigEOS):
_optimizer_config(config_eos, 24) _optimizer_config(config_eos, 24)
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
optimization = GeneticOptimization(fixed_seed=1) optimization = GeneticOptimization(fixed_seed=1)
optimization.simulation.battery = MagicMock(spec=Battery) optimization.simulation.battery = MagicMock(spec=Battery)
optimization.simulation.battery.current_soc_percentage.return_value = 40.0 optimization.simulation.battery.current_soc_percentage.return_value = 40.0
@@ -555,7 +555,7 @@ def test_maximum_soc_before_deadline_counts(config_eos: ConfigEOS):
def _run(config_eos: ConfigEOS, **battery_extra) -> list[float]: def _run(config_eos: ConfigEOS, **battery_extra) -> list[float]:
hours = 24 hours = 24
_optimizer_config(config_eos, hours) _optimizer_config(config_eos, hours)
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
CacheEnergyManagementStore().clear() CacheEnergyManagementStore().clear()
solution = GeneticOptimization(fixed_seed=42).optimize_ems( solution = GeneticOptimization(fixed_seed=42).optimize_ems(
parameters=_full_charge_parameters(hours, **battery_extra), start_hour=0, ngen=40 parameters=_full_charge_parameters(hours, **battery_extra), start_hour=0, ngen=40
+5 -5
View File
@@ -90,7 +90,7 @@ def test_grid_export_rates_reach_the_solution(config_eos: ConfigEOS):
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
CacheEnergyManagementStore().clear() CacheEnergyManagementStore().clear()
hours = 24 hours = 24
@@ -172,7 +172,7 @@ def test_ev_deadline_slot_resolution(config_eos: ConfigEOS):
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0, second=0, microsecond=0))
optimization = GeneticOptimization(fixed_seed=1) optimization = GeneticOptimization(fixed_seed=1)
optimization._slot0_datetime = optimization.ems.start_datetime optimization._slot0_datetime = optimization.ems.start_datetime
slot0 = optimization._slot0_datetime slot0 = optimization._slot0_datetime
@@ -213,7 +213,7 @@ def test_ev_soc_penalty_reads_the_deadline_slot(config_eos: ConfigEOS):
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0, second=0, microsecond=0))
optimization = GeneticOptimization(fixed_seed=1) optimization = GeneticOptimization(fixed_seed=1)
simulation_result = {"EAuto_SoC_pro_Stunde": [20.0, 35.0, 50.0, 80.0]} simulation_result = {"EAuto_SoC_pro_Stunde": [20.0, 35.0, 50.0, 80.0]}
@@ -250,7 +250,7 @@ def test_ev_deadline_charges_before_departure(config_eos: ConfigEOS):
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
CacheEnergyManagementStore().clear() CacheEnergyManagementStore().clear()
parameters = _ev_deadline_parameters(hours, min_soc_max_duration_h=6) parameters = _ev_deadline_parameters(hours, min_soc_max_duration_h=6)
@@ -289,7 +289,7 @@ def _terminal_value_run(
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
CacheEnergyManagementStore().clear() CacheEnergyManagementStore().clear()
if prices is None: if prices is None:
+116
View File
@@ -163,3 +163,119 @@ def test_snapshot_and_warm_start_preserve_aware_instants(
assert restored.start_solution_datetime is not None assert restored.start_solution_datetime is not None
assert restored.start_solution_datetime.timestamp() == expected.timestamp() assert restored.start_solution_datetime.timestamp() == expected.timestamp()
assert restored.start_solution_datetime.utcoffset() == expected.utcoffset() assert restored.start_solution_datetime.utcoffset() == expected.utcoffset()
def _partial_first_slot_run(config_eos, timestamp: str, initial_soc_percentage: int = 20):
"""Run GENETIC with AC charge at full power in slot 0 only.
1 h slots, 2 h control horizon, no tail. Battery 10 kWh (at 20 % unless
given), 2000 W charge power, ideal efficiencies; base load 400 Wh per hour,
no PV.
"""
config_eos.merge_settings_from_dict(
{
"general": {"latitude": 52.52, "longitude": 13.405},
"prediction": {"hours": 24},
"optimization": {
"genetic": {
"interval_sec": 3600,
"horizon_hours": 2,
"tail_horizon_hours": 0,
"terminal_value_mode": "FIXED",
}
},
}
)
start = to_datetime(timestamp).in_timezone("Europe/Berlin")
get_ems(init=True).set_start_datetime(start)
count = start.hour + 2
parameters = GeneticOptimizationParameters.model_validate(
{
"ems": {
"pv_forecast_wh": [0.0] * count,
"total_load": [400.0] * count,
"electricity_price_per_wh": [0.0001] * count,
"feed_in_tariff_per_wh": 0.0,
"price_per_wh_battery": 0.0,
},
"pv_battery": {
"device_id": "battery1",
"capacity_wh": 10000,
"initial_soc_percentage": initial_soc_percentage,
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"max_charge_power_w": 2000,
"charging_efficiency": 1.0,
"discharging_efficiency": 1.0,
},
"inverter": {
"device_id": "inverter1",
"battery_id": "battery1",
"max_power_wh": 5000,
"ac_to_dc_efficiency": 1.0,
"dc_to_ac_efficiency": 1.0,
},
"ev": None,
}
)
optimizer = GeneticOptimization(fixed_seed=42)
def full_ac_charge_in_first_slot(*args, **kwargs):
genome = optimizer.create_individual()
genome[:] = [0] * len(genome)
genome[0] = 3 * len(optimizer.bat_possible_charge_values) - 1
return genome, {}
with patch.object(optimizer, "optimize", side_effect=full_ac_charge_in_first_slot):
solution = optimizer.optimize_ems(parameters)
return optimizer, solution
def test_running_slot_is_planned_for_the_remaining_time_only(config_eos):
"""A run at 10:45 has 15 min of slot 0 left, not a full hour.
Charge power, load and grid energy of slot 0 shrink to a quarter; slot 1
is a full slot again.
"""
optimizer, solution = _partial_first_slot_run(config_eos, "2026-09-16T10:45:00+02:00")
assert optimizer.first_slot_fraction == pytest.approx(0.25)
assert solution.first_slot_fraction == pytest.approx(0.25)
result = solution.result
# Slot 0: 15 min of 400 W base load and 2000 W charge power. The load of
# the result includes the AC charge energy.
assert result.grid_consumption_wh_per_hour[0] == pytest.approx(100.0 + 500.0)
assert result.load_wh_per_hour[0] == pytest.approx(100.0 + 500.0)
# SoC at the start of each slot: 500 Wh stored in 15 min, 20 % -> 25 %.
assert result.battery_soc_per_hour[:2] == pytest.approx([20.0, 25.0])
# Slot 1 is a full slot again.
assert result.grid_consumption_wh_per_hour[1] == pytest.approx(400.0)
def test_run_on_a_slot_boundary_plans_a_full_first_slot(config_eos):
"""A run exactly at the start of the slot keeps the full slot."""
optimizer, solution = _partial_first_slot_run(config_eos, "2026-09-16T10:00:00+02:00")
assert optimizer.first_slot_fraction == pytest.approx(1.0)
assert solution.first_slot_fraction == pytest.approx(1.0)
result = solution.result
assert result.grid_consumption_wh_per_hour[0] == pytest.approx(400.0 + 2000.0)
assert result.battery_soc_per_hour[:2] == pytest.approx([20.0, 40.0])
def test_running_slot_ac_charge_factor_is_not_cut_for_a_full_slot(config_eos):
"""The plan clamps the AC charge factor to the headroom of the remaining time.
At 90 % there are 1000 Wh of headroom. A full hour at 2000 W would exceed it
and the factor would be cut to 0.5; the 15 min left store only 500 Wh, so
full power is sent for the running slot.
"""
_, solution = _partial_first_slot_run(
config_eos, "2026-09-16T10:45:00+02:00", initial_soc_percentage=90
)
assert solution.result.battery_soc_per_hour[:2] == pytest.approx([90.0, 95.0])
plan = solution.energy_management_plan()
battery_instructions = [
instruction for instruction in plan.instructions if instruction.resource_id == "battery1"
]
assert battery_instructions[0].operation_mode_factor == pytest.approx(1.0)
+1 -1
View File
@@ -46,7 +46,7 @@ def _setup(config_eos: ConfigEOS, horizon_hours: int) -> GeneticOptimizationPara
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
CacheEnergyManagementStore().clear() CacheEnergyManagementStore().clear()
return GeneticOptimizationParameters.model_validate( return GeneticOptimizationParameters.model_validate(
dict( dict(
+1 -1
View File
@@ -34,7 +34,7 @@ def _configure_hourly_grid(config_eos: ConfigEOS) -> None:
}, },
} }
) )
get_ems(init=True).set_start_datetime(to_datetime().set(hour=0, minute=0)) get_ems(init=True).set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
def test_fitness_cache_max_entries_setting_defaults_to_unbounded(): def test_fitness_cache_max_entries_setting_defaults_to_unbounded():
+74
View File
@@ -541,3 +541,77 @@ def test_battery_discharge_limit_caps_load_and_grid_export():
assert initial_soc_wh - battery.soc_wh == pytest.approx(1000.0) assert initial_soc_wh - battery.soc_wh == pytest.approx(1000.0)
assert grid_import == pytest.approx(500.0) assert grid_import == pytest.approx(500.0)
assert grid_export == 0.0 assert grid_export == 0.0
class TestFirstSlotFraction:
"""A run within slot 0 simulates only the remaining part of that slot."""
@staticmethod
def _inverter(first_slot_fraction=0.25, battery=None, **parameters):
predictor = Mock()
predictor.calculate_expected_direct_consumption.side_effect = min
with patch(
"akkudoktoreos.devices.genetic.inverter.get_eos_load_interpolator",
return_value=predictor,
):
inverter = Inverter(
InverterParameters(
device_id="inverter1",
max_power_wh=4000.0,
battery_id=battery.parameters.device_id if battery else None,
**parameters,
),
battery=battery,
first_slot_fraction=first_slot_fraction,
)
return inverter, predictor
def test_slot_0_moves_only_the_remaining_part(self):
inverter, _ = self._inverter()
grid_export, _, losses, _ = inverter.process_energy(5000.0, 0.0, hour=0)
assert grid_export == pytest.approx(1000.0)
assert losses == pytest.approx(4000.0)
grid_export, _, losses, _ = inverter.process_energy(5000.0, 0.0, hour=1)
assert grid_export == pytest.approx(4000.0)
assert losses == pytest.approx(1000.0)
def test_self_consumption_table_gets_the_power_of_the_remaining_part(self):
"""250 Wh in 15 min is 1000 W, not 250 W."""
inverter, predictor = self._inverter()
inverter.process_energy(500.0, 250.0, hour=0)
predictor.calculate_expected_direct_consumption.assert_called_with(1000.0, 2000.0)
def test_efficiency_curve_is_read_at_the_power_of_the_remaining_part(self):
inverter, _ = self._inverter(
dc_to_ac_efficiency_curve=[(0.0, 0.97), (0.25, 0.97), (1.0, 0.90)]
)
# 1000 Wh in 15 min is the full 4000 W.
assert inverter.dc_to_ac_efficiency_at(1000.0, 0.25) == pytest.approx(0.90)
assert inverter.dc_to_ac_efficiency_at(1000.0) == pytest.approx(0.97)
def test_ac_charge_in_slot_0_uses_the_remaining_part(self):
battery = Battery(
SolarPanelBatteryParameters(
device_id="battery1",
capacity_wh=40_000,
initial_soc_percentage=0,
min_soc_percentage=0,
max_charge_power_w=8_000,
charging_efficiency=1.0,
),
prediction_hours=2,
first_slot_fraction=0.25,
)
battery.set_charge_per_hour(np.ones(2))
inverter, _ = self._inverter(
battery=battery, ac_to_dc_efficiency=1.0, ac_charge_limits_total_charge=True
)
inverter.begin_ac_charge_slot(0, 0.5)
ac_wh, _ = inverter.charge_battery_from_grid(0, 0.5)
# Half the charge power for 15 min.
assert ac_wh == pytest.approx(1000.0)
@pytest.mark.parametrize("fraction", [0.0, 1.01])
def test_invalid_fraction_is_rejected(self, fraction):
with pytest.raises(ValueError, match="first_slot_fraction"):
self._inverter(first_slot_fraction=fraction)
+1 -1
View File
@@ -74,7 +74,7 @@ def _parameters(
}, },
} }
) )
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0)) ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
CacheEnergyManagementStore().clear() CacheEnergyManagementStore().clear()
return GeneticOptimizationParameters.model_validate( return GeneticOptimizationParameters.model_validate(
dict( dict(
+1 -1
View File
@@ -30,7 +30,7 @@ def _configure_hourly_grid(config_eos: ConfigEOS, *, start_hour: int = 0) -> Non
}, },
} }
) )
get_ems(init=True).set_start_datetime(to_datetime().set(hour=start_hour, minute=0)) get_ems(init=True).set_start_datetime(to_datetime().set(hour=start_hour, minute=0, second=0, microsecond=0))
def test_ev_repair_is_resimulated_before_fitness_assignment(config_eos: ConfigEOS): def test_ev_repair_is_resimulated_before_fitness_assignment(config_eos: ConfigEOS):