mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 15:06:20 +01:00
fix(genetic): plan the running slot only for the remaining time
A run within a slot (e.g. 10:45 with hourly slots) planned slot 0 as a full slot, although the SoC is measured at the run time. Slot 0 now moves only the remaining part of the slot energy: battery, EV and inverter energy caps, SoC power limit tables and the slot's PV and load forecast are scaled by first_slot_fraction; efficiency curves are read at the power of that part. The plan's SoC headroom clamp of the AC charge factor uses the same part, and the GENETIC result reports first_slot_fraction. A run on a slot boundary is unchanged. Additional changes Pin GENETIC test start times to the full hour; their results now depend on seconds within the slot Document first_slot_fraction for consumers of GENETIC results Refs: #1543 Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com> Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
committed by
Bobby Noelte
co-authored by
Claude Opus 5.5
parent
7e10f64048
commit
0bf9f50b97
@@ -91,6 +91,11 @@ time, charging power and supported charge rates.
|
|||||||
|
|
||||||
- Runtime forecast arrays start at local midnight and use the configured slot interval.
|
- Runtime forecast arrays start at local midnight and use the configured slot interval.
|
||||||
Energy is **Wh per slot**, not W or kWh. A constant 1,000 W load uses 250 Wh in 15 minutes.
|
Energy is **Wh per slot**, not W or kWh. A constant 1,000 W load uses 250 Wh in 15 minutes.
|
||||||
|
- A run within a slot plans the first slot only for the time left in it, given as
|
||||||
|
`first_slot_fraction` in the GENETIC result (0.25 for a run at 10:45 with hourly
|
||||||
|
slots). The energies, costs and SoC change of that slot cover only that part, and its
|
||||||
|
charge/discharge factors are the power for the remaining time. A run on a slot
|
||||||
|
boundary plans a full first slot (`first_slot_fraction` 1.0).
|
||||||
- Runtime purchase and sale prices are **currency per Wh**: 0.30 EUR/kWh is 0.00030 EUR/Wh.
|
- Runtime purchase and sale prices are **currency per Wh**: 0.30 EUR/kWh is 0.00030 EUR/Wh.
|
||||||
Provider power forecasts are converted by EOS; do not convert them a second time.
|
Provider power forecasts are converted by EOS; do not convert them a second time.
|
||||||
- Read returned timestamps and interval information instead of assuming 24 hourly values
|
- Read returned timestamps and interval information instead of assuming 24 hourly values
|
||||||
|
|||||||
@@ -11060,6 +11060,14 @@
|
|||||||
"description": "Duration of one result/control slot in seconds.",
|
"description": "Duration of one result/control slot in seconds.",
|
||||||
"default": 3600
|
"default": 3600
|
||||||
},
|
},
|
||||||
|
"first_slot_fraction": {
|
||||||
|
"type": "number",
|
||||||
|
"maximum": 1.0,
|
||||||
|
"exclusiveMinimum": 0.0,
|
||||||
|
"title": "First Slot Fraction",
|
||||||
|
"description": "Part of the first control slot that was still ahead when the optimization ran (0.25 for a run at 10:45 with hourly slots). The results of the first slot cover only that part, and its factors are chosen for it. 1.0 for a run on a slot boundary.",
|
||||||
|
"default": 1.0
|
||||||
|
},
|
||||||
"eautocharge_hours_float": {
|
"eautocharge_hours_float": {
|
||||||
"anyOf": [
|
"anyOf": [
|
||||||
{
|
{
|
||||||
|
|||||||
@@ -406,17 +406,33 @@ class Battery:
|
|||||||
parameters: BaseBatteryParameters,
|
parameters: BaseBatteryParameters,
|
||||||
prediction_hours: int,
|
prediction_hours: int,
|
||||||
slot_duration_h: float = 1.0,
|
slot_duration_h: float = 1.0,
|
||||||
|
first_slot_fraction: float = 1.0,
|
||||||
):
|
):
|
||||||
# `prediction_hours` is the number of optimization slots, not hours. At
|
# `prediction_hours` is the number of optimization slots, not hours. At
|
||||||
# the default optimization interval of 3600 s, slot_duration_h is 1.0 and
|
# the default optimization interval of 3600 s, slot_duration_h is 1.0 and
|
||||||
# the slot count equals the hour count, so existing callers are
|
# the slot count equals the hour count, so existing callers are
|
||||||
# unaffected. At 900 s (15 min) slot_duration_h is 0.25 and there are 4x
|
# unaffected. At 900 s (15 min) slot_duration_h is 0.25 and there are 4x
|
||||||
# as many slots, each able to move a quarter of the hourly energy.
|
# as many slots, each able to move a quarter of the hourly energy.
|
||||||
|
#
|
||||||
|
# `first_slot_fraction` is the part of slot 0 still ahead when the
|
||||||
|
# optimization runs within that slot (0.25 at 10:45 with hourly slots).
|
||||||
|
# Slot 0 then moves only that fraction of the slot energy; the slot's
|
||||||
|
# power limits and power dependent efficiencies stay the same.
|
||||||
|
if not 0.0 < first_slot_fraction <= 1.0:
|
||||||
|
raise ValueError(f"first_slot_fraction must be in (0, 1], got {first_slot_fraction}.")
|
||||||
self.parameters = parameters
|
self.parameters = parameters
|
||||||
self.prediction_hours = prediction_hours
|
self.prediction_hours = prediction_hours
|
||||||
self.slot_duration_h = slot_duration_h
|
self.slot_duration_h = slot_duration_h
|
||||||
|
self.first_slot_fraction = first_slot_fraction
|
||||||
self._setup()
|
self._setup()
|
||||||
|
|
||||||
|
def slot_scale(self, hour: int) -> float:
|
||||||
|
"""Return the part of the slot duration that is simulated for slot ``hour``.
|
||||||
|
|
||||||
|
``first_slot_fraction`` for slot 0, 1.0 for every later slot.
|
||||||
|
"""
|
||||||
|
return self.first_slot_fraction if hour == 0 else 1.0
|
||||||
|
|
||||||
def _setup(self) -> None:
|
def _setup(self) -> None:
|
||||||
"""Sets up the battery parameters based on provided parameters."""
|
"""Sets up the battery parameters based on provided parameters."""
|
||||||
self.capacity_wh = self.parameters.capacity_wh
|
self.capacity_wh = self.parameters.capacity_wh
|
||||||
@@ -548,24 +564,30 @@ class Battery:
|
|||||||
self._curves.reset(self.prediction_hours)
|
self._curves.reset(self.prediction_hours)
|
||||||
self._charge_limit_raw_wh_per_slot = [float("inf")] * self.prediction_hours
|
self._charge_limit_raw_wh_per_slot = [float("inf")] * self.prediction_hours
|
||||||
|
|
||||||
def _discharge_slot_cap_wh(self) -> float:
|
def _discharge_slot_cap_wh(self, hour: int) -> float:
|
||||||
"""Return the raw discharge energy of one slot [Wh] at the current SoC."""
|
"""Return the raw discharge energy of slot ``hour`` [Wh] at the current SoC."""
|
||||||
curves = self._curves
|
curves = self._curves
|
||||||
if curves is None or curves.discharge_limit_wh_by_soc is None:
|
if curves is None or curves.discharge_limit_wh_by_soc is None:
|
||||||
return self.max_discharge_power_w * self.slot_duration_h
|
return self.max_discharge_power_w * self.slot_duration_h * self.slot_scale(hour)
|
||||||
return _table_entry(
|
return _table_entry(
|
||||||
curves.discharge_limit_wh_by_soc,
|
curves.discharge_limit_wh_by_soc,
|
||||||
int(self.soc_wh * curves.soc_index_per_wh + 0.5),
|
int(self.soc_wh * curves.soc_index_per_wh + 0.5),
|
||||||
)
|
) * self.slot_scale(hour)
|
||||||
|
|
||||||
def _discharging_efficiency_at(self, slot_raw_wh: float) -> float:
|
def _discharging_efficiency_at(self, slot_raw_wh: float, scale: float = 1.0) -> float:
|
||||||
"""Return the discharging efficiency at the slot power of ``slot_raw_wh``."""
|
"""Return the discharging efficiency at the slot power of ``slot_raw_wh``.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
slot_raw_wh: Raw discharge energy of the slot [Wh].
|
||||||
|
scale: Simulated part of the slot duration (see ``slot_scale``); the
|
||||||
|
power is the energy divided by that part of the slot.
|
||||||
|
"""
|
||||||
curves = self._curves
|
curves = self._curves
|
||||||
if curves is None or curves.discharging_efficiency_by_power is None:
|
if curves is None or curves.discharging_efficiency_by_power is None:
|
||||||
return self.discharging_efficiency
|
return self.discharging_efficiency
|
||||||
return _table_entry(
|
return _table_entry(
|
||||||
curves.discharging_efficiency_by_power,
|
curves.discharging_efficiency_by_power,
|
||||||
int(slot_raw_wh * curves.discharge_index_per_wh + 0.5),
|
int(slot_raw_wh / scale * curves.discharge_index_per_wh + 0.5),
|
||||||
)
|
)
|
||||||
|
|
||||||
def limit_slot_charge(self, hour: int, raw_wh: float) -> None:
|
def limit_slot_charge(self, hour: int, raw_wh: float) -> None:
|
||||||
@@ -582,24 +604,29 @@ class Battery:
|
|||||||
self._charge_limit_raw_wh_per_slot[hour], max(float(raw_wh), 0.0)
|
self._charge_limit_raw_wh_per_slot[hour], max(float(raw_wh), 0.0)
|
||||||
)
|
)
|
||||||
|
|
||||||
def rated_discharge_energy_wh(self) -> float:
|
def rated_discharge_energy_wh(self, hour: Optional[int] = None) -> float:
|
||||||
"""Return the DC energy one full-power discharge slot delivers.
|
"""Return the DC energy a full-power discharge delivers in one slot.
|
||||||
|
|
||||||
This is the reference a grid-export rate is applied to: a rate of 0.5
|
This is the reference a grid-export rate is applied to: a rate of 0.5
|
||||||
exports at most half the battery's rated discharge power, independent of
|
exports at most half the battery's rated discharge power, independent of
|
||||||
how much of the slot budget self-consumption already used.
|
how much of the slot budget self-consumption already used.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
hour: Slot index. Slot 0 delivers only ``first_slot_fraction`` of
|
||||||
|
the slot energy. None gives a full slot.
|
||||||
"""
|
"""
|
||||||
rated_slot_wh = self.max_discharge_power_w * self.slot_duration_h
|
scale = 1.0 if hour is None else self.slot_scale(hour)
|
||||||
return rated_slot_wh * self._discharging_efficiency_at(rated_slot_wh)
|
rated_slot_wh = self.max_discharge_power_w * self.slot_duration_h * scale
|
||||||
|
return rated_slot_wh * self._discharging_efficiency_at(rated_slot_wh, scale)
|
||||||
|
|
||||||
def remaining_discharge_energy_wh(self, hour: int) -> float:
|
def remaining_discharge_energy_wh(self, hour: int) -> float:
|
||||||
"""Return DC energy still deliverable within one optimization slot."""
|
"""Return DC energy still deliverable within one optimization slot."""
|
||||||
discharged_raw_wh = self._discharged_raw_wh_per_slot[hour]
|
discharged_raw_wh = self._discharged_raw_wh_per_slot[hour]
|
||||||
raw_power_remaining_wh = max(self._discharge_slot_cap_wh() - discharged_raw_wh, 0.0)
|
raw_power_remaining_wh = max(self._discharge_slot_cap_wh(hour) - discharged_raw_wh, 0.0)
|
||||||
raw_soc_available_wh = max(self.soc_wh - self.min_soc_wh, 0.0)
|
raw_soc_available_wh = max(self.soc_wh - self.min_soc_wh, 0.0)
|
||||||
raw_remaining_wh = min(raw_power_remaining_wh, raw_soc_available_wh)
|
raw_remaining_wh = min(raw_power_remaining_wh, raw_soc_available_wh)
|
||||||
return raw_remaining_wh * self._discharging_efficiency_at(
|
return raw_remaining_wh * self._discharging_efficiency_at(
|
||||||
discharged_raw_wh + raw_remaining_wh
|
discharged_raw_wh + raw_remaining_wh, self.slot_scale(hour)
|
||||||
)
|
)
|
||||||
|
|
||||||
def discharge_released(self, hour: int) -> bool:
|
def discharge_released(self, hour: int) -> bool:
|
||||||
@@ -672,22 +699,26 @@ class Battery:
|
|||||||
|
|
||||||
# Maximum raw discharge due to power limit, scaled to the slot duration.
|
# Maximum raw discharge due to power limit, scaled to the slot duration.
|
||||||
# The power limit is a power [W]; energy movable in one slot is
|
# The power limit is a power [W]; energy movable in one slot is
|
||||||
# power x slot_duration_h. With a battery profile the limit and the
|
# power x slot_duration_h, and only the remaining part of slot 0 when
|
||||||
# efficiency are looked up inline (no calls): this runs for every slot
|
# the optimization runs within it. With a battery profile the limit and
|
||||||
# of every candidate plan.
|
# the efficiency are looked up inline (no calls): this runs for every
|
||||||
|
# slot of every candidate plan.
|
||||||
discharged_raw_wh = self._discharged_raw_wh_per_slot[hour]
|
discharged_raw_wh = self._discharged_raw_wh_per_slot[hour]
|
||||||
discharging_efficiency = self.discharging_efficiency
|
discharging_efficiency = self.discharging_efficiency
|
||||||
|
scale = self.first_slot_fraction if hour == 0 else 1.0
|
||||||
curves = self._curves
|
curves = self._curves
|
||||||
if curves is None:
|
if curves is None:
|
||||||
slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h
|
slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h * scale
|
||||||
raw_withdrawal_wh = min(raw_available_wh, max(slot_cap_wh - discharged_raw_wh, 0.0))
|
raw_withdrawal_wh = min(raw_available_wh, max(slot_cap_wh - discharged_raw_wh, 0.0))
|
||||||
else:
|
else:
|
||||||
limits = curves.discharge_limit_wh_by_soc
|
limits = curves.discharge_limit_wh_by_soc
|
||||||
if limits is None:
|
if limits is None:
|
||||||
slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h
|
slot_cap_wh = self.max_discharge_power_w * self.slot_duration_h * scale
|
||||||
else:
|
else:
|
||||||
index = int(self.soc_wh * curves.soc_index_per_wh + 0.5)
|
index = int(self.soc_wh * curves.soc_index_per_wh + 0.5)
|
||||||
slot_cap_wh = limits[index] if 0 <= index <= 100 else _table_entry(limits, index)
|
slot_cap_wh = (
|
||||||
|
limits[index] if 0 <= index <= 100 else _table_entry(limits, index)
|
||||||
|
) * scale
|
||||||
raw_withdrawal_wh = slot_cap_wh - discharged_raw_wh
|
raw_withdrawal_wh = slot_cap_wh - discharged_raw_wh
|
||||||
if raw_withdrawal_wh < 0.0:
|
if raw_withdrawal_wh < 0.0:
|
||||||
raw_withdrawal_wh = 0.0
|
raw_withdrawal_wh = 0.0
|
||||||
@@ -702,7 +733,8 @@ class Battery:
|
|||||||
if raw_estimate_wh > raw_withdrawal_wh:
|
if raw_estimate_wh > raw_withdrawal_wh:
|
||||||
raw_estimate_wh = raw_withdrawal_wh
|
raw_estimate_wh = raw_withdrawal_wh
|
||||||
index = int(
|
index = int(
|
||||||
(discharged_raw_wh + raw_estimate_wh) * curves.discharge_index_per_wh + 0.5
|
(discharged_raw_wh + raw_estimate_wh) / scale * curves.discharge_index_per_wh
|
||||||
|
+ 0.5
|
||||||
)
|
)
|
||||||
discharging_efficiency = efficiencies[index] if index <= 100 else efficiencies[-1]
|
discharging_efficiency = efficiencies[index] if index <= 100 else efficiencies[-1]
|
||||||
|
|
||||||
@@ -804,9 +836,11 @@ class Battery:
|
|||||||
charged_raw_wh = self._charged_raw_wh_per_slot[hour]
|
charged_raw_wh = self._charged_raw_wh_per_slot[hour]
|
||||||
# Scale the power cap [W] to a per-slot energy cap [Wh] (W x slot hours).
|
# Scale the power cap [W] to a per-slot energy cap [Wh] (W x slot hours).
|
||||||
# At slot_duration_h=1.0 (hourly) this equals the legacy power value.
|
# At slot_duration_h=1.0 (hourly) this equals the legacy power value.
|
||||||
|
# Slot 0 only has its remaining part when the run starts within it.
|
||||||
|
scale = self.first_slot_fraction if hour == 0 else 1.0
|
||||||
max_charge_per_slot_wh_fast = max(
|
max_charge_per_slot_wh_fast = max(
|
||||||
min(
|
min(
|
||||||
self.max_charge_power_w * self.slot_duration_h,
|
self.max_charge_power_w * self.slot_duration_h * scale,
|
||||||
self._charge_limit_raw_wh_per_slot[hour],
|
self._charge_limit_raw_wh_per_slot[hour],
|
||||||
)
|
)
|
||||||
- charged_raw_wh,
|
- charged_raw_wh,
|
||||||
@@ -824,7 +858,7 @@ class Battery:
|
|||||||
index = int(soc_wh_fast * curves.soc_index_per_wh + 0.5)
|
index = int(soc_wh_fast * curves.soc_index_per_wh + 0.5)
|
||||||
soc_limit_raw_wh = (
|
soc_limit_raw_wh = (
|
||||||
limits[index] if 0 <= index <= 100 else _table_entry(limits, index)
|
limits[index] if 0 <= index <= 100 else _table_entry(limits, index)
|
||||||
) - charged_raw_wh
|
) * scale - charged_raw_wh
|
||||||
if soc_limit_raw_wh < 0.0:
|
if soc_limit_raw_wh < 0.0:
|
||||||
soc_limit_raw_wh = 0.0
|
soc_limit_raw_wh = 0.0
|
||||||
efficiencies = curves.charging_efficiency_by_power
|
efficiencies = curves.charging_efficiency_by_power
|
||||||
@@ -840,7 +874,9 @@ class Battery:
|
|||||||
intended_raw_wh = soc_limit_raw_wh
|
intended_raw_wh = soc_limit_raw_wh
|
||||||
if intended_raw_wh < 0.0:
|
if intended_raw_wh < 0.0:
|
||||||
intended_raw_wh = 0.0
|
intended_raw_wh = 0.0
|
||||||
index = int((charged_raw_wh + intended_raw_wh) * curves.charge_index_per_wh + 0.5)
|
index = int(
|
||||||
|
(charged_raw_wh + intended_raw_wh) / scale * curves.charge_index_per_wh + 0.5
|
||||||
|
)
|
||||||
charging_efficiency_fast = efficiencies[index] if index <= 100 else efficiencies[-1]
|
charging_efficiency_fast = efficiencies[index] if index <= 100 else efficiencies[-1]
|
||||||
|
|
||||||
# Decide mode & determine raw_request_wh and raw_charge_wh
|
# Decide mode & determine raw_request_wh and raw_charge_wh
|
||||||
|
|||||||
@@ -137,12 +137,26 @@ class Inverter:
|
|||||||
parameters: InverterParameters,
|
parameters: InverterParameters,
|
||||||
battery: Optional[Battery] = None,
|
battery: Optional[Battery] = None,
|
||||||
slot_duration_h: float = 1.0,
|
slot_duration_h: float = 1.0,
|
||||||
|
first_slot_fraction: float = 1.0,
|
||||||
):
|
):
|
||||||
|
# `first_slot_fraction` is the part of slot 0 still ahead when the
|
||||||
|
# optimization runs within that slot; slot 0 then moves only that part
|
||||||
|
# of the slot energy (see Battery).
|
||||||
|
if not 0.0 < first_slot_fraction <= 1.0:
|
||||||
|
raise ValueError(f"first_slot_fraction must be in (0, 1], got {first_slot_fraction}.")
|
||||||
self.parameters: InverterParameters = parameters
|
self.parameters: InverterParameters = parameters
|
||||||
self.battery: Optional[Battery] = battery
|
self.battery: Optional[Battery] = battery
|
||||||
self.slot_duration_h: float = slot_duration_h
|
self.slot_duration_h: float = slot_duration_h
|
||||||
|
self.first_slot_fraction: float = first_slot_fraction
|
||||||
self._setup()
|
self._setup()
|
||||||
|
|
||||||
|
def slot_scale(self, hour: int) -> float:
|
||||||
|
"""Return the part of the slot duration that is simulated for slot ``hour``.
|
||||||
|
|
||||||
|
``first_slot_fraction`` for slot 0, 1.0 for every later slot.
|
||||||
|
"""
|
||||||
|
return self.first_slot_fraction if hour == 0 else 1.0
|
||||||
|
|
||||||
def _setup(self) -> None:
|
def _setup(self) -> None:
|
||||||
if self.battery and self.parameters.battery_id != self.battery.parameters.device_id:
|
if self.battery and self.parameters.battery_id != self.battery.parameters.device_id:
|
||||||
error_msg = f"Battery ID mismatch - {self.parameters.battery_id} is configured; got {self.battery.parameters.device_id}."
|
error_msg = f"Battery ID mismatch - {self.parameters.battery_id} is configured; got {self.battery.parameters.device_id}."
|
||||||
@@ -167,19 +181,24 @@ class Inverter:
|
|||||||
self.max_ac_charge_power_w = self.parameters.max_ac_charge_power_w
|
self.max_ac_charge_power_w = self.parameters.max_ac_charge_power_w
|
||||||
self.ac_charge_limits_total_charge = self.parameters.ac_charge_limits_total_charge
|
self.ac_charge_limits_total_charge = self.parameters.ac_charge_limits_total_charge
|
||||||
|
|
||||||
def dc_to_ac_efficiency_at(self, ac_wh: float) -> float:
|
def dc_to_ac_efficiency_at(self, ac_wh: float, scale: float = 1.0) -> float:
|
||||||
"""Return the DC-to-AC efficiency of a conversion delivering ``ac_wh`` in one slot.
|
"""Return the DC-to-AC efficiency of a conversion delivering ``ac_wh`` in one slot.
|
||||||
|
|
||||||
Without ``dc_to_ac_efficiency_curve`` this is the constant
|
Without ``dc_to_ac_efficiency_curve`` this is the constant
|
||||||
``dc_to_ac_efficiency``. With a curve, the efficiency is interpolated at
|
``dc_to_ac_efficiency``. With a curve, the efficiency is interpolated at
|
||||||
the load fraction ``ac_wh / max_power_wh`` of this slot. ``max_power_wh``
|
the load fraction ``ac_wh / (max_power_wh * scale)`` of this slot.
|
||||||
is already scaled to the slot duration, so the fraction equals the mean
|
``max_power_wh`` is already scaled to the slot duration, so the fraction
|
||||||
AC power relative to the rated power.
|
equals the mean AC power relative to the rated power.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
ac_wh: AC energy of the conversion in this slot [Wh].
|
||||||
|
scale: Simulated part of the slot duration (see ``slot_scale``).
|
||||||
"""
|
"""
|
||||||
if self.dc_to_ac_efficiency_curve is None:
|
if self.dc_to_ac_efficiency_curve is None:
|
||||||
return self.dc_to_ac_efficiency
|
return self.dc_to_ac_efficiency
|
||||||
curve: list[tuple[float, float]] = self.dc_to_ac_efficiency_curve
|
curve: list[tuple[float, float]] = self.dc_to_ac_efficiency_curve
|
||||||
load_fraction = ac_wh / self.max_power_wh if self.max_power_wh > 0 else 0.0
|
slot_max_power_wh = self.max_power_wh * scale
|
||||||
|
load_fraction = ac_wh / slot_max_power_wh if slot_max_power_wh > 0 else 0.0
|
||||||
# This runs for every battery discharge of every candidate plan. Find
|
# This runs for every battery discharge of every candidate plan. Find
|
||||||
# the curve segment by bisection on the load fractions, split off once
|
# the curve segment by bisection on the load fractions, split off once
|
||||||
# per curve, instead of walking the points. The segment and the
|
# per curve, instead of walking the points. The segment and the
|
||||||
@@ -234,7 +253,11 @@ class Inverter:
|
|||||||
"""
|
"""
|
||||||
if self.ac_charge_limits_total_charge and self.battery and factor > 0.0:
|
if self.ac_charge_limits_total_charge and self.battery and factor > 0.0:
|
||||||
self.battery.limit_slot_charge(
|
self.battery.limit_slot_charge(
|
||||||
hour, self.battery.max_charge_power_w * self.slot_duration_h * factor
|
hour,
|
||||||
|
self.battery.max_charge_power_w
|
||||||
|
* self.slot_duration_h
|
||||||
|
* self.slot_scale(hour)
|
||||||
|
* factor,
|
||||||
)
|
)
|
||||||
|
|
||||||
def charge_battery_from_grid(self, hour: int, factor: float) -> tuple[float, float]:
|
def charge_battery_from_grid(self, hour: int, factor: float) -> tuple[float, float]:
|
||||||
@@ -250,9 +273,10 @@ class Inverter:
|
|||||||
"""
|
"""
|
||||||
if not self.battery or factor <= 0.0:
|
if not self.battery or factor <= 0.0:
|
||||||
return 0.0, 0.0
|
return 0.0, 0.0
|
||||||
|
scale = self.slot_scale(hour)
|
||||||
if self.ac_charge_limits_total_charge:
|
if self.ac_charge_limits_total_charge:
|
||||||
stored, battery_losses = self.battery.charge_energy(
|
stored, battery_losses = self.battery.charge_energy(
|
||||||
self.battery.max_charge_power_w * self.slot_duration_h * factor, hour
|
self.battery.max_charge_power_w * self.slot_duration_h * scale * factor, hour
|
||||||
)
|
)
|
||||||
else:
|
else:
|
||||||
stored, battery_losses = self.battery.charge_energy(None, hour, charge_factor=factor)
|
stored, battery_losses = self.battery.charge_energy(None, hour, charge_factor=factor)
|
||||||
@@ -262,7 +286,7 @@ class Inverter:
|
|||||||
# curve the efficiency is the one at the AC load actually drawn.
|
# curve the efficiency is the one at the AC load actually drawn.
|
||||||
curve = self.ac_to_dc_efficiency_curve
|
curve = self.ac_to_dc_efficiency_curve
|
||||||
if curve is not None:
|
if curve is not None:
|
||||||
ac_energy = solve_ac_for_charge_dc_energy(curve, dc_energy, self.max_power_wh)
|
ac_energy = solve_ac_for_charge_dc_energy(curve, dc_energy, self.max_power_wh * scale)
|
||||||
else:
|
else:
|
||||||
ac_energy = dc_energy / self.ac_to_dc_efficiency
|
ac_energy = dc_energy / self.ac_to_dc_efficiency
|
||||||
return ac_energy, battery_losses + (ac_energy - dc_energy)
|
return ac_energy, battery_losses + (ac_energy - dc_energy)
|
||||||
@@ -273,18 +297,20 @@ class Inverter:
|
|||||||
dc_request: float,
|
dc_request: float,
|
||||||
requested_ac_wh: float,
|
requested_ac_wh: float,
|
||||||
dc_to_ac_efficiency: float,
|
dc_to_ac_efficiency: float,
|
||||||
|
scale: float = 1.0,
|
||||||
) -> float:
|
) -> float:
|
||||||
"""Return the AC energy of a discharge that delivered ``battery_discharge_dc``.
|
"""Return the AC energy of a discharge that delivered ``battery_discharge_dc``.
|
||||||
|
|
||||||
If the battery delivered less than requested (low state of charge or its
|
If the battery delivered less than requested (low state of charge or its
|
||||||
power limit), the conversion runs at a lower AC load than requested. With
|
power limit), the conversion runs at a lower AC load than requested. With
|
||||||
an efficiency curve the efficiency must then be the one at the AC energy
|
an efficiency curve the efficiency must then be the one at the AC energy
|
||||||
that is actually delivered, not at the request.
|
that is actually delivered, not at the request. ``scale`` is the
|
||||||
|
simulated part of the slot duration (see ``slot_scale``).
|
||||||
"""
|
"""
|
||||||
curve = self.dc_to_ac_efficiency_curve
|
curve = self.dc_to_ac_efficiency_curve
|
||||||
if curve is not None and battery_discharge_dc < dc_request * (1.0 - 1e-12):
|
if curve is not None and battery_discharge_dc < dc_request * (1.0 - 1e-12):
|
||||||
return solve_ac_for_dc_energy(
|
return solve_ac_for_dc_energy(
|
||||||
curve, battery_discharge_dc, self.max_power_wh, requested_ac_wh
|
curve, battery_discharge_dc, self.max_power_wh * scale, requested_ac_wh
|
||||||
)
|
)
|
||||||
return battery_discharge_dc * dc_to_ac_efficiency
|
return battery_discharge_dc * dc_to_ac_efficiency
|
||||||
|
|
||||||
@@ -293,15 +319,16 @@ class Inverter:
|
|||||||
battery = self.battery
|
battery = self.battery
|
||||||
if not battery or requested_ac_wh <= 0.0:
|
if not battery or requested_ac_wh <= 0.0:
|
||||||
return 0.0, 0.0
|
return 0.0, 0.0
|
||||||
|
scale = self.first_slot_fraction if hour == 0 else 1.0
|
||||||
if type(battery) is not Battery:
|
if type(battery) is not Battery:
|
||||||
# Another battery implementation: ask it, step by step.
|
# Another battery implementation: ask it, step by step.
|
||||||
if not battery.discharge_released(hour):
|
if not battery.discharge_released(hour):
|
||||||
return 0.0, 0.0
|
return 0.0, 0.0
|
||||||
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh)
|
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh, scale)
|
||||||
dc_request = requested_ac_wh / dc_to_ac_efficiency
|
dc_request = requested_ac_wh / dc_to_ac_efficiency
|
||||||
battery_discharge_dc, discharge_losses = battery.discharge_energy(dc_request, hour)
|
battery_discharge_dc, discharge_losses = battery.discharge_energy(dc_request, hour)
|
||||||
battery_discharge_ac = self._delivered_ac_wh(
|
battery_discharge_ac = self._delivered_ac_wh(
|
||||||
battery_discharge_dc, dc_request, requested_ac_wh, dc_to_ac_efficiency
|
battery_discharge_dc, dc_request, requested_ac_wh, dc_to_ac_efficiency, scale
|
||||||
)
|
)
|
||||||
inverter_discharge_losses = battery_discharge_dc - battery_discharge_ac
|
inverter_discharge_losses = battery_discharge_dc - battery_discharge_ac
|
||||||
return battery_discharge_ac, discharge_losses + inverter_discharge_losses
|
return battery_discharge_ac, discharge_losses + inverter_discharge_losses
|
||||||
@@ -319,7 +346,7 @@ class Inverter:
|
|||||||
if self.dc_to_ac_efficiency_curve is None:
|
if self.dc_to_ac_efficiency_curve is None:
|
||||||
dc_to_ac_efficiency = self.dc_to_ac_efficiency
|
dc_to_ac_efficiency = self.dc_to_ac_efficiency
|
||||||
else:
|
else:
|
||||||
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh)
|
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh, scale)
|
||||||
dc_request = requested_ac_wh / dc_to_ac_efficiency
|
dc_request = requested_ac_wh / dc_to_ac_efficiency
|
||||||
|
|
||||||
if battery._curves is not None:
|
if battery._curves is not None:
|
||||||
@@ -335,7 +362,10 @@ class Inverter:
|
|||||||
# Match Battery.discharge_energy(): preserve a SoC below the reserve.
|
# Match Battery.discharge_energy(): preserve a SoC below the reserve.
|
||||||
return 0.0, 0.0
|
return 0.0, 0.0
|
||||||
max_raw_wh = max(
|
max_raw_wh = max(
|
||||||
battery.max_discharge_power_w * battery.slot_duration_h - discharged_raw_wh[hour],
|
battery.max_discharge_power_w
|
||||||
|
* battery.slot_duration_h
|
||||||
|
* (battery.first_slot_fraction if hour == 0 else 1.0)
|
||||||
|
- discharged_raw_wh[hour],
|
||||||
0.0,
|
0.0,
|
||||||
)
|
)
|
||||||
max_deliverable_wh = min(raw_available_wh, max_raw_wh) * discharging_efficiency
|
max_deliverable_wh = min(raw_available_wh, max_raw_wh) * discharging_efficiency
|
||||||
@@ -354,7 +384,7 @@ class Inverter:
|
|||||||
battery_discharge_ac = solve_ac_for_dc_energy(
|
battery_discharge_ac = solve_ac_for_dc_energy(
|
||||||
self.dc_to_ac_efficiency_curve,
|
self.dc_to_ac_efficiency_curve,
|
||||||
battery_discharge_dc,
|
battery_discharge_dc,
|
||||||
self.max_power_wh,
|
self.max_power_wh * scale,
|
||||||
requested_ac_wh,
|
requested_ac_wh,
|
||||||
)
|
)
|
||||||
else:
|
else:
|
||||||
@@ -402,12 +432,16 @@ class Inverter:
|
|||||||
if consumption < 0.0:
|
if consumption < 0.0:
|
||||||
consumption = 0.0
|
consumption = 0.0
|
||||||
battery = self.battery
|
battery = self.battery
|
||||||
max_power_wh = self.max_power_wh
|
# Slot 0 only has its remaining part when the run starts within it:
|
||||||
|
# the inverter moves that part of the slot energy, and the slot's
|
||||||
|
# energies are converted to power over that part of the slot.
|
||||||
|
scale = self.first_slot_fraction if hour == 0 else 1.0
|
||||||
|
max_power_wh = self.max_power_wh * scale
|
||||||
|
|
||||||
# Convert interval energy [Wh] to mean power [W] for the probability
|
# Convert interval energy [Wh] to mean power [W] for the probability
|
||||||
# lookup, then convert its expected direct power back to slot energy.
|
# lookup, then convert its expected direct power back to slot energy.
|
||||||
if generation > 0.0 and consumption > 0.0:
|
if generation > 0.0 and consumption > 0.0:
|
||||||
slot_duration_h = self.slot_duration_h
|
slot_duration_h = self.slot_duration_h * scale
|
||||||
expected_direct_power_w = (
|
expected_direct_power_w = (
|
||||||
self.self_consumption_predictor.calculate_expected_direct_consumption(
|
self.self_consumption_predictor.calculate_expected_direct_consumption(
|
||||||
consumption / slot_duration_h,
|
consumption / slot_duration_h,
|
||||||
@@ -504,14 +538,14 @@ class Inverter:
|
|||||||
# limited by the energy the battery can actually deliver.
|
# limited by the energy the battery can actually deliver.
|
||||||
remaining_battery_dc = battery.remaining_discharge_energy_wh(hour)
|
remaining_battery_dc = battery.remaining_discharge_energy_wh(hour)
|
||||||
remaining_battery_ac = remaining_battery_dc * self.dc_to_ac_efficiency_at(
|
remaining_battery_ac = remaining_battery_dc * self.dc_to_ac_efficiency_at(
|
||||||
remaining_battery_dc
|
remaining_battery_dc, scale
|
||||||
)
|
)
|
||||||
# The rate caps the export against the battery's *rated* discharge
|
# The rate caps the export against the battery's *rated* discharge
|
||||||
# power, so it stays a plain power setpoint ("export at 50 %") that
|
# power, so it stays a plain power setpoint ("export at 50 %") that
|
||||||
# does not silently grow when self-consumption used less of the slot.
|
# does not silently grow when self-consumption used less of the slot.
|
||||||
# At factor 1.0 this bound never binds; behaviour is unchanged.
|
# At factor 1.0 this bound never binds; behaviour is unchanged.
|
||||||
rated_export_dc = battery.rated_discharge_energy_wh() * export_factor
|
rated_export_dc = battery.rated_discharge_energy_wh(hour) * export_factor
|
||||||
rated_export_ac = rated_export_dc * self.dc_to_ac_efficiency_at(rated_export_dc)
|
rated_export_ac = rated_export_dc * self.dc_to_ac_efficiency_at(rated_export_dc, scale)
|
||||||
export_capacity = remaining_inverter_ac_capacity
|
export_capacity = remaining_inverter_ac_capacity
|
||||||
if remaining_battery_ac < export_capacity:
|
if remaining_battery_ac < export_capacity:
|
||||||
export_capacity = remaining_battery_ac
|
export_capacity = remaining_battery_ac
|
||||||
|
|||||||
@@ -1056,6 +1056,37 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
"""Genomes and device arrays start at now, independently of wall-clock hour."""
|
"""Genomes and device arrays start at now, independently of wall-clock hour."""
|
||||||
return 0
|
return 0
|
||||||
|
|
||||||
|
def _remaining_first_slot_fraction(self) -> float:
|
||||||
|
"""Return the part of slot 0 that is still ahead of the run.
|
||||||
|
|
||||||
|
The run start is rounded down to the slot (``ems.start_datetime``),
|
||||||
|
while the measurements and the plan apply from the unrounded run time
|
||||||
|
(``ems.observation_datetime``). A run at 10:45 with hourly slots has
|
||||||
|
a quarter of slot 0 left. A run on a slot boundary, or without a
|
||||||
|
usable run time, keeps the full slot (1.0).
|
||||||
|
"""
|
||||||
|
slot_seconds = self.slot_duration_h * 3600
|
||||||
|
slot0 = self.ems.start_datetime
|
||||||
|
observed = self.ems.observation_datetime
|
||||||
|
elapsed_s = (observed - slot0).total_seconds()
|
||||||
|
if elapsed_s <= 0.0:
|
||||||
|
return 1.0
|
||||||
|
if elapsed_s >= slot_seconds:
|
||||||
|
logger.debug(
|
||||||
|
"Run time {} is not within slot 0 starting {}; planning a full first slot.",
|
||||||
|
observed,
|
||||||
|
slot0,
|
||||||
|
)
|
||||||
|
return 1.0
|
||||||
|
fraction = (slot_seconds - elapsed_s) / slot_seconds
|
||||||
|
logger.debug(
|
||||||
|
"Run at {} within slot 0 starting {}: {:.3f} of slot 0 left.",
|
||||||
|
observed,
|
||||||
|
slot0,
|
||||||
|
fraction,
|
||||||
|
)
|
||||||
|
return fraction
|
||||||
|
|
||||||
def _start_day_slot(self) -> int:
|
def _start_day_slot(self) -> int:
|
||||||
"""Offset used only to trim legacy midnight-indexed forecast inputs."""
|
"""Offset used only to trim legacy midnight-indexed forecast inputs."""
|
||||||
sd = self.ems.start_datetime
|
sd = self.ems.start_datetime
|
||||||
@@ -1085,6 +1116,9 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
# Populated from parameters.pv_battery.grid_export_rates in optimize_ems;
|
# Populated from parameters.pv_battery.grid_export_rates in optimize_ems;
|
||||||
# the single full-power default keeps the all-or-nothing export.
|
# the single full-power default keeps the all-or-nothing export.
|
||||||
self.bat_possible_grid_export_values: list[float] = [1.0]
|
self.bat_possible_grid_export_values: list[float] = [1.0]
|
||||||
|
# Part of slot 0 still ahead of the run (1.0 on a slot boundary), set
|
||||||
|
# per run by optimize_ems().
|
||||||
|
self.first_slot_fraction: float = 1.0
|
||||||
# Slot by which the EV has to reach its target SoC. None means the SoC is
|
# Slot by which the EV has to reach its target SoC. None means the SoC is
|
||||||
# only required at the end of the horizon (the behaviour without a deadline).
|
# only required at the end of the horizon (the behaviour without a deadline).
|
||||||
self._ev_soc_deadline_slot: Optional[int] = None
|
self._ev_soc_deadline_slot: Optional[int] = None
|
||||||
@@ -2524,15 +2558,18 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
return schedule
|
return schedule
|
||||||
|
|
||||||
max_stored_wh = ev.max_charge_power_w * self.slot_duration_h * ev.charging_efficiency
|
max_stored_wh = ev.max_charge_power_w * self.slot_duration_h * ev.charging_efficiency
|
||||||
|
first_slot_fraction = getattr(self, "first_slot_fraction", 1.0)
|
||||||
remaining_wh = required_stored_wh
|
remaining_wh = required_stored_wh
|
||||||
for slot in candidates:
|
for slot in candidates:
|
||||||
required_rate = remaining_wh / max(max_stored_wh, 1e-9)
|
# Slot 0 only has its remaining part when the run starts within it.
|
||||||
|
slot_stored_wh = max_stored_wh * (first_slot_fraction if slot == 0 else 1.0)
|
||||||
|
required_rate = remaining_wh / max(slot_stored_wh, 1e-9)
|
||||||
rate, rate_index = next(
|
rate, rate_index = next(
|
||||||
(item for item in positive_rates if item[0] >= required_rate),
|
(item for item in positive_rates if item[0] >= required_rate),
|
||||||
positive_rates[-1],
|
positive_rates[-1],
|
||||||
)
|
)
|
||||||
schedule[slot] = rate_index
|
schedule[slot] = rate_index
|
||||||
remaining_wh -= max_stored_wh * rate
|
remaining_wh -= slot_stored_wh * rate
|
||||||
if remaining_wh <= 1e-9:
|
if remaining_wh <= 1e-9:
|
||||||
break
|
break
|
||||||
return schedule
|
return schedule
|
||||||
@@ -3856,8 +3893,12 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
# AC charging at this hour is economically unjustified.
|
# AC charging at this hour is economically unjustified.
|
||||||
# Penalty = excess cost per Wh × DC energy requested this slot.
|
# Penalty = excess cost per Wh × DC energy requested this slot.
|
||||||
# max_charge_power_w is a power [W]; the energy movable in
|
# max_charge_power_w is a power [W]; the energy movable in
|
||||||
# one slot is power × slot_duration_h (¼ at 15 min).
|
# one slot is power × slot_duration_h (¼ at 15 min), and
|
||||||
dc_wh = bat.max_charge_power_w * self.slot_duration_h * ac_factor
|
# only the remaining part of slot 0 within that slot.
|
||||||
|
slot_scale = getattr(self, "first_slot_fraction", 1.0) if hour == 0 else 1.0
|
||||||
|
dc_wh = (
|
||||||
|
bat.max_charge_power_w * self.slot_duration_h * slot_scale * ac_factor
|
||||||
|
)
|
||||||
ac_wh = dc_wh / max(inv.ac_to_dc_efficiency, 1e-9)
|
ac_wh = dc_wh / max(inv.ac_to_dc_efficiency, 1e-9)
|
||||||
excess_cost_per_wh = break_even_price - best_uncovered_price
|
excess_cost_per_wh = break_even_price - best_uncovered_price
|
||||||
gesamtbilanz += ac_wh * excess_cost_per_wh * ac_penalty_factor
|
gesamtbilanz += ac_wh * excess_cost_per_wh * ac_penalty_factor
|
||||||
@@ -4215,6 +4256,9 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
# break-even lookup must be rebuilt lazily on first evaluation.
|
# break-even lookup must be rebuilt lazily on first evaluation.
|
||||||
self._ac_break_even_best_prices = None
|
self._ac_break_even_best_prices = None
|
||||||
|
|
||||||
|
# A run within a slot plans slot 0 for the remaining time only.
|
||||||
|
self.first_slot_fraction = self._remaining_first_slot_fraction()
|
||||||
|
|
||||||
# Initialize PV and EV batteries. slot_duration_h lets the Battery scale
|
# Initialize PV and EV batteries. slot_duration_h lets the Battery scale
|
||||||
# its power caps (max_charge_power_w) to a per-slot energy cap.
|
# its power caps (max_charge_power_w) to a per-slot energy cap.
|
||||||
akku: Optional[Battery] = None
|
akku: Optional[Battery] = None
|
||||||
@@ -4223,6 +4267,7 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
parameters.pv_battery,
|
parameters.pv_battery,
|
||||||
prediction_hours=self.control_end_slot,
|
prediction_hours=self.control_end_slot,
|
||||||
slot_duration_h=self.slot_duration_h,
|
slot_duration_h=self.slot_duration_h,
|
||||||
|
first_slot_fraction=self.first_slot_fraction,
|
||||||
)
|
)
|
||||||
akku.set_charge_per_hour(np.full(self.control_end_slot, 0))
|
akku.set_charge_per_hour(np.full(self.control_end_slot, 0))
|
||||||
|
|
||||||
@@ -4232,6 +4277,7 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
parameters.ev,
|
parameters.ev,
|
||||||
prediction_hours=self.control_end_slot,
|
prediction_hours=self.control_end_slot,
|
||||||
slot_duration_h=self.slot_duration_h,
|
slot_duration_h=self.slot_duration_h,
|
||||||
|
first_slot_fraction=self.first_slot_fraction,
|
||||||
)
|
)
|
||||||
eauto.set_charge_per_hour(np.full(self.control_end_slot, 1))
|
eauto.set_charge_per_hour(np.full(self.control_end_slot, 1))
|
||||||
self.optimize_ev = (
|
self.optimize_ev = (
|
||||||
@@ -4356,6 +4402,7 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
parameters.inverter,
|
parameters.inverter,
|
||||||
battery=akku,
|
battery=akku,
|
||||||
slot_duration_h=self.slot_duration_h,
|
slot_duration_h=self.slot_duration_h,
|
||||||
|
first_slot_fraction=self.first_slot_fraction,
|
||||||
)
|
)
|
||||||
|
|
||||||
# Prepare device simulation
|
# Prepare device simulation
|
||||||
@@ -4386,6 +4433,16 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
"elect_revenue_per_hour_arr",
|
"elect_revenue_per_hour_arr",
|
||||||
):
|
):
|
||||||
setattr(self.simulation, name, getattr(self.simulation, name)[: self.control_slots])
|
setattr(self.simulation, name, getattr(self.simulation, name)[: self.control_slots])
|
||||||
|
# Only the remaining part of slot 0 is ahead: its PV and load forecast
|
||||||
|
# shrink to that part (spread evenly over the slot). Prices are per Wh
|
||||||
|
# and stay. The terminal value curve above keeps the full forecasts.
|
||||||
|
if self.first_slot_fraction < 1.0:
|
||||||
|
for name in ("load_energy_array", "pv_prediction_wh"):
|
||||||
|
values = getattr(self.simulation, name)
|
||||||
|
if values is not None and len(values) > 0:
|
||||||
|
values = np.array(values, dtype=float)
|
||||||
|
values[0] *= self.first_slot_fraction
|
||||||
|
setattr(self.simulation, name, values)
|
||||||
|
|
||||||
# Setup the DEAP environment and optimization process. The appliance
|
# Setup the DEAP environment and optimization process. The appliance
|
||||||
# genome layout (built above) drives the appliance gene block; evaluate
|
# genome layout (built above) drives the appliance gene block; evaluate
|
||||||
@@ -4481,6 +4538,7 @@ class GeneticOptimization(OptimizationBase):
|
|||||||
**{
|
**{
|
||||||
"parameters": parameters,
|
"parameters": parameters,
|
||||||
"interval_seconds": self._genetic_cfg.interval_sec,
|
"interval_seconds": self._genetic_cfg.interval_sec,
|
||||||
|
"first_slot_fraction": self.first_slot_fraction,
|
||||||
"start_hour": start_hour,
|
"start_hour": start_hour,
|
||||||
"extra_data": extra_data,
|
"extra_data": extra_data,
|
||||||
"fitness_history": self.fitness_history,
|
"fitness_history": self.fitness_history,
|
||||||
|
|||||||
@@ -474,6 +474,18 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
|||||||
default=3600, description="Duration of one result/control slot in seconds."
|
default=3600, description="Duration of one result/control slot in seconds."
|
||||||
)
|
)
|
||||||
|
|
||||||
|
first_slot_fraction: float = Field(
|
||||||
|
default=1.0,
|
||||||
|
gt=0.0,
|
||||||
|
le=1.0,
|
||||||
|
description=(
|
||||||
|
"Part of the first control slot that was still ahead when the "
|
||||||
|
"optimization ran (0.25 for a run at 10:45 with hourly slots). The "
|
||||||
|
"results of the first slot cover only that part, and its factors are "
|
||||||
|
"chosen for it. 1.0 for a run on a slot boundary."
|
||||||
|
),
|
||||||
|
)
|
||||||
|
|
||||||
@field_validator("start_solution_datetime", mode="before")
|
@field_validator("start_solution_datetime", mode="before")
|
||||||
@classmethod
|
@classmethod
|
||||||
def transform_start_solution_datetime(cls, value: Any) -> Optional[DateTime]:
|
def transform_start_solution_datetime(cls, value: Any) -> Optional[DateTime]:
|
||||||
@@ -621,6 +633,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
|||||||
discharge_allowed: bool,
|
discharge_allowed: bool,
|
||||||
soc_pct: float,
|
soc_pct: float,
|
||||||
battery_grid_export_allowed: bool = False,
|
battery_grid_export_allowed: bool = False,
|
||||||
|
slot_fraction: float = 1.0,
|
||||||
) -> tuple[float, float, bool, bool]:
|
) -> tuple[float, float, bool, bool]:
|
||||||
"""Clamp raw genetic gene values by the battery's actual SOC at that hour.
|
"""Clamp raw genetic gene values by the battery's actual SOC at that hour.
|
||||||
|
|
||||||
@@ -638,6 +651,10 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
|||||||
(the inverter curtails automatically, but this makes intent clear).
|
(the inverter curtails automatically, but this makes intent clear).
|
||||||
- Discharge: blocked when SOC is at or below min SOC.
|
- Discharge: blocked when SOC is at or below min SOC.
|
||||||
- Battery grid export: blocked when SOC is at or below min SOC.
|
- Battery grid export: blocked when SOC is at or below min SOC.
|
||||||
|
|
||||||
|
``slot_fraction`` is the part of the slot the factors apply to:
|
||||||
|
``first_slot_fraction`` for the running first slot, else 1.0. The
|
||||||
|
headroom check of the AC charge factor uses only that part of the slot.
|
||||||
"""
|
"""
|
||||||
parameters = getattr(self, "parameters", None)
|
parameters = getattr(self, "parameters", None)
|
||||||
# Without parameters, convert the battery settings: they hold no
|
# Without parameters, convert the battery settings: they hold no
|
||||||
@@ -679,7 +696,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
|||||||
)
|
)
|
||||||
# Energy storable in one optimization slot, not per hour: scale the
|
# Energy storable in one optimization slot, not per hour: scale the
|
||||||
# power [W] by the slot duration (1.0 hourly, 0.25 at 15 min).
|
# power [W] by the slot duration (1.0 hourly, 0.25 at 15 min).
|
||||||
slot_duration_h = float(self.interval_seconds) / 3600.0
|
slot_duration_h = float(self.interval_seconds) / 3600.0 * slot_fraction
|
||||||
max_dc_per_slot_wh = (
|
max_dc_per_slot_wh = (
|
||||||
effective_ac * max_ac_cp_w * slot_duration_h * ac_to_dc_eff * ch_eff
|
effective_ac * max_ac_cp_w * slot_duration_h * ac_to_dc_eff * ch_eff
|
||||||
)
|
)
|
||||||
@@ -821,6 +838,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
|||||||
discharge_allowed_hour,
|
discharge_allowed_hour,
|
||||||
soc_h_pct,
|
soc_h_pct,
|
||||||
battery_grid_export_allowed_hour,
|
battery_grid_export_allowed_hour,
|
||||||
|
self.first_slot_fraction if result_idx == 0 else 1.0,
|
||||||
)
|
)
|
||||||
operation_mode, operation_mode_factor = self._battery_operation_from_solution(
|
operation_mode, operation_mode_factor = self._battery_operation_from_solution(
|
||||||
eff_ac, eff_dc, eff_dis, eff_grid_export, battery_grid_export_factor_hour
|
eff_ac, eff_dc, eff_dis, eff_grid_export, battery_grid_export_factor_hour
|
||||||
@@ -1097,6 +1115,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
|||||||
bool(self.discharge_allowed[hour_idx]),
|
bool(self.discharge_allowed[hour_idx]),
|
||||||
soc_h_pct,
|
soc_h_pct,
|
||||||
battery_grid_export_allowed_hour,
|
battery_grid_export_allowed_hour,
|
||||||
|
self.first_slot_fraction if result_idx == 0 else 1.0,
|
||||||
)
|
)
|
||||||
operation_mode, operation_mode_factor = self._battery_operation_from_solution(
|
operation_mode, operation_mode_factor = self._battery_operation_from_solution(
|
||||||
eff_ac,
|
eff_ac,
|
||||||
|
|||||||
@@ -760,3 +760,88 @@ class TestPowerCurves:
|
|||||||
def test_invalid_curves_are_rejected(self, field, value):
|
def test_invalid_curves_are_rejected(self, field, value):
|
||||||
with pytest.raises(ValidationError):
|
with pytest.raises(ValidationError):
|
||||||
SolarPanelBatteryParameters(device_id="battery1", capacity_wh=10_000, **{field: value})
|
SolarPanelBatteryParameters(device_id="battery1", capacity_wh=10_000, **{field: value})
|
||||||
|
|
||||||
|
|
||||||
|
class TestFirstSlotFraction:
|
||||||
|
"""A run within slot 0 simulates only the remaining part of that slot."""
|
||||||
|
|
||||||
|
@staticmethod
|
||||||
|
def _battery(first_slot_fraction=1.0, soc=50, **curves):
|
||||||
|
params = SolarPanelBatteryParameters(
|
||||||
|
device_id="battery1",
|
||||||
|
capacity_wh=40_000,
|
||||||
|
initial_soc_percentage=soc,
|
||||||
|
min_soc_percentage=0,
|
||||||
|
max_soc_percentage=100,
|
||||||
|
max_charge_power_w=8_000,
|
||||||
|
max_discharge_power_w=4_000,
|
||||||
|
charging_efficiency=1.0,
|
||||||
|
discharging_efficiency=1.0,
|
||||||
|
**curves,
|
||||||
|
)
|
||||||
|
battery = Battery(
|
||||||
|
params, prediction_hours=4, slot_duration_h=1.0, first_slot_fraction=first_slot_fraction
|
||||||
|
)
|
||||||
|
battery.set_charge_per_hour(np.ones(4))
|
||||||
|
battery.set_discharge_per_hour(np.ones(4))
|
||||||
|
return battery
|
||||||
|
|
||||||
|
def test_slot_0_charges_only_the_remaining_part(self):
|
||||||
|
battery = self._battery(first_slot_fraction=0.25)
|
||||||
|
stored, _ = battery.charge_energy(None, 0, charge_factor=1.0)
|
||||||
|
assert stored == pytest.approx(2_000.0)
|
||||||
|
# Mode 1 (a PV surplus) is capped the same way.
|
||||||
|
assert battery.charge_energy(5_000.0, 0) == pytest.approx((0.0, 0.0))
|
||||||
|
# Slot 1 is a full slot again.
|
||||||
|
stored, _ = battery.charge_energy(None, 1, charge_factor=1.0)
|
||||||
|
assert stored == pytest.approx(8_000.0)
|
||||||
|
|
||||||
|
def test_slot_0_discharges_only_the_remaining_part(self):
|
||||||
|
battery = self._battery(first_slot_fraction=0.25)
|
||||||
|
assert battery.remaining_discharge_energy_wh(0) == pytest.approx(1_000.0)
|
||||||
|
assert battery.rated_discharge_energy_wh(0) == pytest.approx(1_000.0)
|
||||||
|
assert battery.rated_discharge_energy_wh(1) == pytest.approx(4_000.0)
|
||||||
|
assert battery.rated_discharge_energy_wh() == pytest.approx(4_000.0)
|
||||||
|
delivered, _ = battery.discharge_energy(9_000.0, 0)
|
||||||
|
assert delivered == pytest.approx(1_000.0)
|
||||||
|
delivered, _ = battery.discharge_energy(9_000.0, 1)
|
||||||
|
assert delivered == pytest.approx(4_000.0)
|
||||||
|
|
||||||
|
def test_full_fraction_is_the_plain_slot(self):
|
||||||
|
partial = self._battery(first_slot_fraction=1.0)
|
||||||
|
plain = Battery(partial.parameters, prediction_hours=4, slot_duration_h=1.0)
|
||||||
|
plain.set_charge_per_hour(np.ones(4))
|
||||||
|
assert partial.charge_energy(None, 0, charge_factor=1.0) == plain.charge_energy(
|
||||||
|
None, 0, charge_factor=1.0
|
||||||
|
)
|
||||||
|
|
||||||
|
def test_soc_power_limit_scales_with_the_remaining_part(self):
|
||||||
|
battery = self._battery(
|
||||||
|
first_slot_fraction=0.5,
|
||||||
|
charge_power_limit_w_by_soc=[6_000.0] * 101,
|
||||||
|
discharge_power_limit_w_by_soc=[2_000.0] * 101,
|
||||||
|
)
|
||||||
|
stored, _ = battery.charge_energy(None, 0, charge_factor=1.0)
|
||||||
|
assert stored == pytest.approx(3_000.0)
|
||||||
|
delivered, _ = battery.discharge_energy(9_000.0, 0)
|
||||||
|
assert delivered == pytest.approx(1_000.0)
|
||||||
|
|
||||||
|
def test_efficiency_curve_is_read_at_the_power_not_the_energy(self):
|
||||||
|
"""Full power for 15 min has the efficiency of full power, not of 25 %."""
|
||||||
|
curve = [(0.0, 0.95), (0.25, 0.95), (1.0, 0.80)]
|
||||||
|
battery = self._battery(
|
||||||
|
first_slot_fraction=0.25,
|
||||||
|
charging_efficiency_curve=curve,
|
||||||
|
discharging_efficiency_curve=curve,
|
||||||
|
)
|
||||||
|
stored, losses = battery.charge_energy(None, 0, charge_factor=1.0)
|
||||||
|
assert stored + losses == pytest.approx(2_000.0)
|
||||||
|
assert stored == pytest.approx(2_000.0 * 0.80)
|
||||||
|
delivered, losses = battery.discharge_energy(9_000.0, 0)
|
||||||
|
assert delivered + losses == pytest.approx(1_000.0)
|
||||||
|
assert delivered == pytest.approx(1_000.0 * 0.80)
|
||||||
|
|
||||||
|
@pytest.mark.parametrize("fraction", [0.0, -0.1, 1.5])
|
||||||
|
def test_invalid_fraction_is_rejected(self, fraction):
|
||||||
|
with pytest.raises(ValueError, match="first_slot_fraction"):
|
||||||
|
self._battery(first_slot_fraction=fraction)
|
||||||
|
|||||||
@@ -510,7 +510,7 @@ def _full_charge_parameters(hours: int, **battery_extra) -> GeneticOptimizationP
|
|||||||
|
|
||||||
def test_full_charge_slot_resolution(config_eos: ConfigEOS):
|
def test_full_charge_slot_resolution(config_eos: ConfigEOS):
|
||||||
_optimizer_config(config_eos, 24)
|
_optimizer_config(config_eos, 24)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
optimization = GeneticOptimization(fixed_seed=1)
|
optimization = GeneticOptimization(fixed_seed=1)
|
||||||
optimization._slot0_datetime = optimization.ems.start_datetime
|
optimization._slot0_datetime = optimization.ems.start_datetime
|
||||||
slot0 = optimization._slot0_datetime
|
slot0 = optimization._slot0_datetime
|
||||||
@@ -530,7 +530,7 @@ def test_full_charge_slot_resolution(config_eos: ConfigEOS):
|
|||||||
|
|
||||||
def test_maximum_soc_before_deadline_counts(config_eos: ConfigEOS):
|
def test_maximum_soc_before_deadline_counts(config_eos: ConfigEOS):
|
||||||
_optimizer_config(config_eos, 24)
|
_optimizer_config(config_eos, 24)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
optimization = GeneticOptimization(fixed_seed=1)
|
optimization = GeneticOptimization(fixed_seed=1)
|
||||||
optimization.simulation.battery = MagicMock(spec=Battery)
|
optimization.simulation.battery = MagicMock(spec=Battery)
|
||||||
optimization.simulation.battery.current_soc_percentage.return_value = 40.0
|
optimization.simulation.battery.current_soc_percentage.return_value = 40.0
|
||||||
@@ -555,7 +555,7 @@ def test_maximum_soc_before_deadline_counts(config_eos: ConfigEOS):
|
|||||||
def _run(config_eos: ConfigEOS, **battery_extra) -> list[float]:
|
def _run(config_eos: ConfigEOS, **battery_extra) -> list[float]:
|
||||||
hours = 24
|
hours = 24
|
||||||
_optimizer_config(config_eos, hours)
|
_optimizer_config(config_eos, hours)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
CacheEnergyManagementStore().clear()
|
CacheEnergyManagementStore().clear()
|
||||||
solution = GeneticOptimization(fixed_seed=42).optimize_ems(
|
solution = GeneticOptimization(fixed_seed=42).optimize_ems(
|
||||||
parameters=_full_charge_parameters(hours, **battery_extra), start_hour=0, ngen=40
|
parameters=_full_charge_parameters(hours, **battery_extra), start_hour=0, ngen=40
|
||||||
|
|||||||
@@ -90,7 +90,7 @@ def test_grid_export_rates_reach_the_solution(config_eos: ConfigEOS):
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
CacheEnergyManagementStore().clear()
|
CacheEnergyManagementStore().clear()
|
||||||
|
|
||||||
hours = 24
|
hours = 24
|
||||||
@@ -172,7 +172,7 @@ def test_ev_deadline_slot_resolution(config_eos: ConfigEOS):
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0, second=0, microsecond=0))
|
||||||
optimization = GeneticOptimization(fixed_seed=1)
|
optimization = GeneticOptimization(fixed_seed=1)
|
||||||
optimization._slot0_datetime = optimization.ems.start_datetime
|
optimization._slot0_datetime = optimization.ems.start_datetime
|
||||||
slot0 = optimization._slot0_datetime
|
slot0 = optimization._slot0_datetime
|
||||||
@@ -213,7 +213,7 @@ def test_ev_soc_penalty_reads_the_deadline_slot(config_eos: ConfigEOS):
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=10, minute=0, second=0, microsecond=0))
|
||||||
optimization = GeneticOptimization(fixed_seed=1)
|
optimization = GeneticOptimization(fixed_seed=1)
|
||||||
simulation_result = {"EAuto_SoC_pro_Stunde": [20.0, 35.0, 50.0, 80.0]}
|
simulation_result = {"EAuto_SoC_pro_Stunde": [20.0, 35.0, 50.0, 80.0]}
|
||||||
|
|
||||||
@@ -250,7 +250,7 @@ def test_ev_deadline_charges_before_departure(config_eos: ConfigEOS):
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
CacheEnergyManagementStore().clear()
|
CacheEnergyManagementStore().clear()
|
||||||
|
|
||||||
parameters = _ev_deadline_parameters(hours, min_soc_max_duration_h=6)
|
parameters = _ev_deadline_parameters(hours, min_soc_max_duration_h=6)
|
||||||
@@ -289,7 +289,7 @@ def _terminal_value_run(
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
CacheEnergyManagementStore().clear()
|
CacheEnergyManagementStore().clear()
|
||||||
|
|
||||||
if prices is None:
|
if prices is None:
|
||||||
|
|||||||
@@ -163,3 +163,119 @@ def test_snapshot_and_warm_start_preserve_aware_instants(
|
|||||||
assert restored.start_solution_datetime is not None
|
assert restored.start_solution_datetime is not None
|
||||||
assert restored.start_solution_datetime.timestamp() == expected.timestamp()
|
assert restored.start_solution_datetime.timestamp() == expected.timestamp()
|
||||||
assert restored.start_solution_datetime.utcoffset() == expected.utcoffset()
|
assert restored.start_solution_datetime.utcoffset() == expected.utcoffset()
|
||||||
|
|
||||||
|
|
||||||
|
def _partial_first_slot_run(config_eos, timestamp: str, initial_soc_percentage: int = 20):
|
||||||
|
"""Run GENETIC with AC charge at full power in slot 0 only.
|
||||||
|
|
||||||
|
1 h slots, 2 h control horizon, no tail. Battery 10 kWh (at 20 % unless
|
||||||
|
given), 2000 W charge power, ideal efficiencies; base load 400 Wh per hour,
|
||||||
|
no PV.
|
||||||
|
"""
|
||||||
|
config_eos.merge_settings_from_dict(
|
||||||
|
{
|
||||||
|
"general": {"latitude": 52.52, "longitude": 13.405},
|
||||||
|
"prediction": {"hours": 24},
|
||||||
|
"optimization": {
|
||||||
|
"genetic": {
|
||||||
|
"interval_sec": 3600,
|
||||||
|
"horizon_hours": 2,
|
||||||
|
"tail_horizon_hours": 0,
|
||||||
|
"terminal_value_mode": "FIXED",
|
||||||
|
}
|
||||||
|
},
|
||||||
|
}
|
||||||
|
)
|
||||||
|
start = to_datetime(timestamp).in_timezone("Europe/Berlin")
|
||||||
|
get_ems(init=True).set_start_datetime(start)
|
||||||
|
count = start.hour + 2
|
||||||
|
parameters = GeneticOptimizationParameters.model_validate(
|
||||||
|
{
|
||||||
|
"ems": {
|
||||||
|
"pv_forecast_wh": [0.0] * count,
|
||||||
|
"total_load": [400.0] * count,
|
||||||
|
"electricity_price_per_wh": [0.0001] * count,
|
||||||
|
"feed_in_tariff_per_wh": 0.0,
|
||||||
|
"price_per_wh_battery": 0.0,
|
||||||
|
},
|
||||||
|
"pv_battery": {
|
||||||
|
"device_id": "battery1",
|
||||||
|
"capacity_wh": 10000,
|
||||||
|
"initial_soc_percentage": initial_soc_percentage,
|
||||||
|
"min_soc_percentage": 0,
|
||||||
|
"max_soc_percentage": 100,
|
||||||
|
"max_charge_power_w": 2000,
|
||||||
|
"charging_efficiency": 1.0,
|
||||||
|
"discharging_efficiency": 1.0,
|
||||||
|
},
|
||||||
|
"inverter": {
|
||||||
|
"device_id": "inverter1",
|
||||||
|
"battery_id": "battery1",
|
||||||
|
"max_power_wh": 5000,
|
||||||
|
"ac_to_dc_efficiency": 1.0,
|
||||||
|
"dc_to_ac_efficiency": 1.0,
|
||||||
|
},
|
||||||
|
"ev": None,
|
||||||
|
}
|
||||||
|
)
|
||||||
|
optimizer = GeneticOptimization(fixed_seed=42)
|
||||||
|
|
||||||
|
def full_ac_charge_in_first_slot(*args, **kwargs):
|
||||||
|
genome = optimizer.create_individual()
|
||||||
|
genome[:] = [0] * len(genome)
|
||||||
|
genome[0] = 3 * len(optimizer.bat_possible_charge_values) - 1
|
||||||
|
return genome, {}
|
||||||
|
|
||||||
|
with patch.object(optimizer, "optimize", side_effect=full_ac_charge_in_first_slot):
|
||||||
|
solution = optimizer.optimize_ems(parameters)
|
||||||
|
return optimizer, solution
|
||||||
|
|
||||||
|
|
||||||
|
def test_running_slot_is_planned_for_the_remaining_time_only(config_eos):
|
||||||
|
"""A run at 10:45 has 15 min of slot 0 left, not a full hour.
|
||||||
|
|
||||||
|
Charge power, load and grid energy of slot 0 shrink to a quarter; slot 1
|
||||||
|
is a full slot again.
|
||||||
|
"""
|
||||||
|
optimizer, solution = _partial_first_slot_run(config_eos, "2026-09-16T10:45:00+02:00")
|
||||||
|
|
||||||
|
assert optimizer.first_slot_fraction == pytest.approx(0.25)
|
||||||
|
assert solution.first_slot_fraction == pytest.approx(0.25)
|
||||||
|
result = solution.result
|
||||||
|
# Slot 0: 15 min of 400 W base load and 2000 W charge power. The load of
|
||||||
|
# the result includes the AC charge energy.
|
||||||
|
assert result.grid_consumption_wh_per_hour[0] == pytest.approx(100.0 + 500.0)
|
||||||
|
assert result.load_wh_per_hour[0] == pytest.approx(100.0 + 500.0)
|
||||||
|
# SoC at the start of each slot: 500 Wh stored in 15 min, 20 % -> 25 %.
|
||||||
|
assert result.battery_soc_per_hour[:2] == pytest.approx([20.0, 25.0])
|
||||||
|
# Slot 1 is a full slot again.
|
||||||
|
assert result.grid_consumption_wh_per_hour[1] == pytest.approx(400.0)
|
||||||
|
|
||||||
|
|
||||||
|
def test_run_on_a_slot_boundary_plans_a_full_first_slot(config_eos):
|
||||||
|
"""A run exactly at the start of the slot keeps the full slot."""
|
||||||
|
optimizer, solution = _partial_first_slot_run(config_eos, "2026-09-16T10:00:00+02:00")
|
||||||
|
|
||||||
|
assert optimizer.first_slot_fraction == pytest.approx(1.0)
|
||||||
|
assert solution.first_slot_fraction == pytest.approx(1.0)
|
||||||
|
result = solution.result
|
||||||
|
assert result.grid_consumption_wh_per_hour[0] == pytest.approx(400.0 + 2000.0)
|
||||||
|
assert result.battery_soc_per_hour[:2] == pytest.approx([20.0, 40.0])
|
||||||
|
|
||||||
|
|
||||||
|
def test_running_slot_ac_charge_factor_is_not_cut_for_a_full_slot(config_eos):
|
||||||
|
"""The plan clamps the AC charge factor to the headroom of the remaining time.
|
||||||
|
|
||||||
|
At 90 % there are 1000 Wh of headroom. A full hour at 2000 W would exceed it
|
||||||
|
and the factor would be cut to 0.5; the 15 min left store only 500 Wh, so
|
||||||
|
full power is sent for the running slot.
|
||||||
|
"""
|
||||||
|
_, solution = _partial_first_slot_run(
|
||||||
|
config_eos, "2026-09-16T10:45:00+02:00", initial_soc_percentage=90
|
||||||
|
)
|
||||||
|
assert solution.result.battery_soc_per_hour[:2] == pytest.approx([90.0, 95.0])
|
||||||
|
plan = solution.energy_management_plan()
|
||||||
|
battery_instructions = [
|
||||||
|
instruction for instruction in plan.instructions if instruction.resource_id == "battery1"
|
||||||
|
]
|
||||||
|
assert battery_instructions[0].operation_mode_factor == pytest.approx(1.0)
|
||||||
|
|||||||
@@ -46,7 +46,7 @@ def _setup(config_eos: ConfigEOS, horizon_hours: int) -> GeneticOptimizationPara
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
CacheEnergyManagementStore().clear()
|
CacheEnergyManagementStore().clear()
|
||||||
return GeneticOptimizationParameters.model_validate(
|
return GeneticOptimizationParameters.model_validate(
|
||||||
dict(
|
dict(
|
||||||
|
|||||||
@@ -34,7 +34,7 @@ def _configure_hourly_grid(config_eos: ConfigEOS) -> None:
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
get_ems(init=True).set_start_datetime(to_datetime().set(hour=0, minute=0))
|
get_ems(init=True).set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
|
|
||||||
|
|
||||||
def test_fitness_cache_max_entries_setting_defaults_to_unbounded():
|
def test_fitness_cache_max_entries_setting_defaults_to_unbounded():
|
||||||
|
|||||||
@@ -541,3 +541,77 @@ def test_battery_discharge_limit_caps_load_and_grid_export():
|
|||||||
assert initial_soc_wh - battery.soc_wh == pytest.approx(1000.0)
|
assert initial_soc_wh - battery.soc_wh == pytest.approx(1000.0)
|
||||||
assert grid_import == pytest.approx(500.0)
|
assert grid_import == pytest.approx(500.0)
|
||||||
assert grid_export == 0.0
|
assert grid_export == 0.0
|
||||||
|
|
||||||
|
|
||||||
|
class TestFirstSlotFraction:
|
||||||
|
"""A run within slot 0 simulates only the remaining part of that slot."""
|
||||||
|
|
||||||
|
@staticmethod
|
||||||
|
def _inverter(first_slot_fraction=0.25, battery=None, **parameters):
|
||||||
|
predictor = Mock()
|
||||||
|
predictor.calculate_expected_direct_consumption.side_effect = min
|
||||||
|
with patch(
|
||||||
|
"akkudoktoreos.devices.genetic.inverter.get_eos_load_interpolator",
|
||||||
|
return_value=predictor,
|
||||||
|
):
|
||||||
|
inverter = Inverter(
|
||||||
|
InverterParameters(
|
||||||
|
device_id="inverter1",
|
||||||
|
max_power_wh=4000.0,
|
||||||
|
battery_id=battery.parameters.device_id if battery else None,
|
||||||
|
**parameters,
|
||||||
|
),
|
||||||
|
battery=battery,
|
||||||
|
first_slot_fraction=first_slot_fraction,
|
||||||
|
)
|
||||||
|
return inverter, predictor
|
||||||
|
|
||||||
|
def test_slot_0_moves_only_the_remaining_part(self):
|
||||||
|
inverter, _ = self._inverter()
|
||||||
|
grid_export, _, losses, _ = inverter.process_energy(5000.0, 0.0, hour=0)
|
||||||
|
assert grid_export == pytest.approx(1000.0)
|
||||||
|
assert losses == pytest.approx(4000.0)
|
||||||
|
grid_export, _, losses, _ = inverter.process_energy(5000.0, 0.0, hour=1)
|
||||||
|
assert grid_export == pytest.approx(4000.0)
|
||||||
|
assert losses == pytest.approx(1000.0)
|
||||||
|
|
||||||
|
def test_self_consumption_table_gets_the_power_of_the_remaining_part(self):
|
||||||
|
"""250 Wh in 15 min is 1000 W, not 250 W."""
|
||||||
|
inverter, predictor = self._inverter()
|
||||||
|
inverter.process_energy(500.0, 250.0, hour=0)
|
||||||
|
predictor.calculate_expected_direct_consumption.assert_called_with(1000.0, 2000.0)
|
||||||
|
|
||||||
|
def test_efficiency_curve_is_read_at_the_power_of_the_remaining_part(self):
|
||||||
|
inverter, _ = self._inverter(
|
||||||
|
dc_to_ac_efficiency_curve=[(0.0, 0.97), (0.25, 0.97), (1.0, 0.90)]
|
||||||
|
)
|
||||||
|
# 1000 Wh in 15 min is the full 4000 W.
|
||||||
|
assert inverter.dc_to_ac_efficiency_at(1000.0, 0.25) == pytest.approx(0.90)
|
||||||
|
assert inverter.dc_to_ac_efficiency_at(1000.0) == pytest.approx(0.97)
|
||||||
|
|
||||||
|
def test_ac_charge_in_slot_0_uses_the_remaining_part(self):
|
||||||
|
battery = Battery(
|
||||||
|
SolarPanelBatteryParameters(
|
||||||
|
device_id="battery1",
|
||||||
|
capacity_wh=40_000,
|
||||||
|
initial_soc_percentage=0,
|
||||||
|
min_soc_percentage=0,
|
||||||
|
max_charge_power_w=8_000,
|
||||||
|
charging_efficiency=1.0,
|
||||||
|
),
|
||||||
|
prediction_hours=2,
|
||||||
|
first_slot_fraction=0.25,
|
||||||
|
)
|
||||||
|
battery.set_charge_per_hour(np.ones(2))
|
||||||
|
inverter, _ = self._inverter(
|
||||||
|
battery=battery, ac_to_dc_efficiency=1.0, ac_charge_limits_total_charge=True
|
||||||
|
)
|
||||||
|
inverter.begin_ac_charge_slot(0, 0.5)
|
||||||
|
ac_wh, _ = inverter.charge_battery_from_grid(0, 0.5)
|
||||||
|
# Half the charge power for 15 min.
|
||||||
|
assert ac_wh == pytest.approx(1000.0)
|
||||||
|
|
||||||
|
@pytest.mark.parametrize("fraction", [0.0, 1.01])
|
||||||
|
def test_invalid_fraction_is_rejected(self, fraction):
|
||||||
|
with pytest.raises(ValueError, match="first_slot_fraction"):
|
||||||
|
self._inverter(first_slot_fraction=fraction)
|
||||||
|
|||||||
@@ -74,7 +74,7 @@ def _parameters(
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0))
|
ems_eos.set_start_datetime(to_datetime().set(hour=0, minute=0, second=0, microsecond=0))
|
||||||
CacheEnergyManagementStore().clear()
|
CacheEnergyManagementStore().clear()
|
||||||
return GeneticOptimizationParameters.model_validate(
|
return GeneticOptimizationParameters.model_validate(
|
||||||
dict(
|
dict(
|
||||||
|
|||||||
@@ -30,7 +30,7 @@ def _configure_hourly_grid(config_eos: ConfigEOS, *, start_hour: int = 0) -> Non
|
|||||||
},
|
},
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
get_ems(init=True).set_start_datetime(to_datetime().set(hour=start_hour, minute=0))
|
get_ems(init=True).set_start_datetime(to_datetime().set(hour=start_hour, minute=0, second=0, microsecond=0))
|
||||||
|
|
||||||
|
|
||||||
def test_ev_repair_is_resimulated_before_fitness_assignment(config_eos: ConfigEOS):
|
def test_ev_repair_is_resimulated_before_fitness_assignment(config_eos: ConfigEOS):
|
||||||
|
|||||||
Reference in New Issue
Block a user