mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2025-10-11 11:56:17 +00:00
Structure code in logically separated submodules (#188)
This commit is contained in:
69
src/akkudoktoreos/devices/inverter.py
Normal file
69
src/akkudoktoreos/devices/inverter.py
Normal file
@@ -0,0 +1,69 @@
|
||||
from pydantic import BaseModel, Field
|
||||
|
||||
from akkudoktoreos.devices.battery import PVAkku
|
||||
|
||||
|
||||
class WechselrichterParameters(BaseModel):
|
||||
max_leistung_wh: float = Field(10000, gt=0)
|
||||
|
||||
|
||||
class Wechselrichter:
|
||||
def __init__(self, parameters: WechselrichterParameters, akku: PVAkku):
|
||||
self.max_leistung_wh = (
|
||||
parameters.max_leistung_wh # Maximum power that the inverter can handle
|
||||
)
|
||||
self.akku = akku # Connection to a battery object
|
||||
|
||||
def energie_verarbeiten(self, erzeugung, verbrauch, hour):
|
||||
verluste = 0 # Losses during processing
|
||||
netzeinspeisung = 0 # Grid feed-in
|
||||
netzbezug = 0.0 # Grid draw
|
||||
eigenverbrauch = 0.0 # Self-consumption
|
||||
|
||||
if erzeugung >= verbrauch:
|
||||
if verbrauch > self.max_leistung_wh:
|
||||
# If consumption exceeds maximum inverter power
|
||||
verluste += erzeugung - self.max_leistung_wh
|
||||
restleistung_nach_verbrauch = self.max_leistung_wh - verbrauch
|
||||
netzbezug = -restleistung_nach_verbrauch # Negative indicates feeding into the grid
|
||||
eigenverbrauch = self.max_leistung_wh
|
||||
else:
|
||||
# Remaining power after consumption
|
||||
restleistung_nach_verbrauch = erzeugung - verbrauch
|
||||
|
||||
# Load battery with excess energy
|
||||
geladene_energie, verluste_laden_akku = self.akku.energie_laden(
|
||||
restleistung_nach_verbrauch, hour
|
||||
)
|
||||
rest_überschuss = restleistung_nach_verbrauch - (
|
||||
geladene_energie + verluste_laden_akku
|
||||
)
|
||||
|
||||
# Feed-in to the grid based on remaining capacity
|
||||
if rest_überschuss > self.max_leistung_wh - verbrauch:
|
||||
netzeinspeisung = self.max_leistung_wh - verbrauch
|
||||
verluste += rest_überschuss - netzeinspeisung
|
||||
else:
|
||||
netzeinspeisung = rest_überschuss
|
||||
|
||||
verluste += verluste_laden_akku
|
||||
eigenverbrauch = verbrauch # Self-consumption is equal to the load
|
||||
|
||||
else:
|
||||
benötigte_energie = verbrauch - erzeugung # Energy needed from external sources
|
||||
max_akku_leistung = self.akku.max_ladeleistung_w # Maximum battery discharge power
|
||||
|
||||
# Calculate remaining AC power available
|
||||
rest_ac_leistung = max(self.max_leistung_wh - erzeugung, 0)
|
||||
|
||||
# Discharge energy from the battery based on need
|
||||
if benötigte_energie < rest_ac_leistung:
|
||||
aus_akku, akku_entladeverluste = self.akku.energie_abgeben(benötigte_energie, hour)
|
||||
else:
|
||||
aus_akku, akku_entladeverluste = self.akku.energie_abgeben(rest_ac_leistung, hour)
|
||||
|
||||
verluste += akku_entladeverluste # Include losses from battery discharge
|
||||
netzbezug = benötigte_energie - aus_akku # Energy drawn from the grid
|
||||
eigenverbrauch = erzeugung + aus_akku # Total self-consumption
|
||||
|
||||
return netzeinspeisung, netzbezug, verluste, eigenverbrauch
|