fix(pvforecast): align the calibration window to the UTC slot grid

Additional fixes
PV meter energy comes from the quality-aware conversion.
Calibration rows are binned by interval start with end-stamped rows.
The fit covers only the period every PV meter covers and stays inside its lookback.
The meter resolution is judged only where every PV meter reports.
Snow feedback derives its window from the same slot window helper and shares one PV meter read per forecast with calibration.
Window bounds and pandas timestamps are converted in one place, always to UTC; fit days are counted in the configured zone.
Calibration tests write meters in bulk, stamp them in the configured zone and check every azimuth bin; snow feedback has its own slot window test.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
Bobby Noelte
2026-11-15 18:30:00 +01:00
co-authored by Claude Opus 5.5
parent 6fad58655f
commit 2bfb6eafab
3 changed files with 595 additions and 77 deletions
+341 -6
View File
@@ -1,5 +1,6 @@
"""Tests for the native (pvlib) PV forecast provider."""
from typing import Any, Optional
from unittest.mock import AsyncMock, Mock, patch
import numpy as np
@@ -15,7 +16,11 @@ from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor
from akkudoktoreos.prediction.pvforecastakkudoktorlocal import (
PVForecastAkkudoktorLocal,
PVForecastAkkudoktorLocalCommonSettings,
SlotWindow,
_slot_window,
_utc_timestamp,
)
from akkudoktoreos.utils.datetimeutil import DateTime, compare_datetimes, to_datetime
LATITUDE = 52.52
LONGITUDE = 13.405
@@ -65,6 +70,14 @@ def synthetic_openmeteo(resolution_minutes: int = 15, models: list[str] | None =
return data
async def _fit(
instance: PVForecastAkkudoktorLocal, frame: pd.DataFrame
) -> Optional[tuple[float, np.ndarray]]:
"""Fit the calibration as a forecast run does: read the PV meter window, then fit."""
return await instance._fit_calibration(frame, await instance._pv_measurement_window())
@pytest_asyncio.fixture
async def pvforecast_instance(config_eos):
config_eos.merge_settings_from_dict(
@@ -286,7 +299,7 @@ async def _feed_native_quarter_hour_measurements(
@pytest.mark.asyncio
async def test_calibration_is_off_by_default(pvforecast_instance):
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
assert await pvforecast_instance._fit_calibration(frame) is None
assert await _fit(pvforecast_instance, frame) is None
@pytest.mark.asyncio
@@ -295,7 +308,7 @@ async def test_calibration_skips_without_measurement_keys(pvforecast_instance):
calibration_enabled=True
)
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
assert await pvforecast_instance._fit_calibration(frame) is None
assert await _fit(pvforecast_instance, frame) is None
@pytest.mark.asyncio
@@ -310,7 +323,7 @@ async def test_calibration_recovers_a_systematic_bias(pvforecast_instance):
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
await _feed_measurements(pvforecast_instance, frame, bias=0.8, key="pv_bias_emr")
calibration = await pvforecast_instance._fit_calibration(frame)
calibration = await _fit(pvforecast_instance, frame)
assert calibration is not None
global_factor, factors = calibration
assert global_factor == pytest.approx(0.8, abs=0.03)
@@ -342,7 +355,7 @@ async def test_calibration_excludes_recent_demand_limited_outage(pvforecast_inst
)
with caplog.at_level("INFO"):
calibration = await pvforecast_instance._fit_calibration(frame)
calibration = await _fit(pvforecast_instance, frame)
assert calibration is not None
global_factor, factors = calibration
@@ -383,7 +396,7 @@ async def test_calibration_uses_real_quarter_hour_measurements(pvforecast_instan
== 15
)
with caplog.at_level("INFO"):
calibration = await pvforecast_instance._fit_calibration(frame)
calibration = await _fit(pvforecast_instance, frame)
assert calibration is not None
global_factor, _ = calibration
@@ -405,7 +418,7 @@ async def test_calibration_factor_is_clamped(pvforecast_instance):
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
await _feed_measurements(pvforecast_instance, frame, bias=0.2, key="pv_clamp_emr")
calibration = await pvforecast_instance._fit_calibration(frame)
calibration = await _fit(pvforecast_instance, frame)
assert calibration is not None
global_factor, _ = calibration
assert global_factor == pytest.approx(0.9)
@@ -724,3 +737,325 @@ def test_file_migration_rejects_invalid_local_settings(config_eos, invalid):
}
}
)
@pytest.mark.parametrize(
("interval_minutes", "lookback_start", "last", "earliest", "expected"),
[
pytest.param(
15,
"2025-06-01T00:00:00Z",
"2025-06-02T00:07:00Z",
["2025-06-01T00:04:50Z"],
("2025-06-01T00:15:00Z", "2025-06-02T00:00:00Z"),
id="unaligned-earliest-rounds-up-to-first-covered-slot",
),
pytest.param(
15,
"2025-06-01T00:00:00Z",
"2025-06-02T00:00:00Z",
["2025-06-01T00:15:00Z"],
("2025-06-01T00:15:00Z", "2025-06-02T00:00:00Z"),
id="on-grid-earliest-is-kept",
),
pytest.param(
15,
"2025-06-01T00:07:00Z",
"2025-06-02T00:00:00Z",
["2025-05-01T00:04:50Z", pd.Timestamp("2025-05-31T23:45:00Z")],
("2025-06-01T00:15:00Z", "2025-06-02T00:00:00Z"),
id="lookback-limited-rounds-up-into-the-lookback",
),
pytest.param(
60,
"2025-06-01T06:00:00+05:45",
"2025-06-02T06:00:00+05:45",
[pd.Timestamp("2025-05-31T23:45:00")],
("2025-06-01T01:00:00Z", "2025-06-02T00:00:00Z"),
id="quarter-hour-offset-zone-on-utc-grid-naive-model-stamp-is-utc",
),
],
)
def test_slot_window_bounds_share_the_utc_slot_grid(
interval_minutes: int,
lookback_start: str,
last: str,
earliest: list[str | pd.Timestamp],
expected: tuple[str, str],
) -> None:
window = _slot_window(
interval_minutes,
to_datetime(lookback_start),
to_datetime(last),
[value if isinstance(value, pd.Timestamp) else to_datetime(value) for value in earliest],
)
assert window == SlotWindow(start=pd.Timestamp(expected[0]), end=pd.Timestamp(expected[1]))
assert window.start_datetime.timezone_name == "UTC"
assert compare_datetimes(window.start_datetime, to_datetime(expected[0])).equal
def test_slot_window_without_a_whole_slot_is_none() -> None:
window = _slot_window(
60,
to_datetime("2025-06-01T00:00:00Z"),
to_datetime("2025-06-01T01:30:00Z"),
[to_datetime("2025-06-01T00:10:00Z")],
)
assert window is None
def _unaligned_meter_series(
frame: pd.DataFrame,
bias: float,
first: DateTime,
until: DateTime,
cadence_minutes: int,
timezone: str = "UTC",
interval_start_labels: bool = True,
) -> pd.Series:
"""Cumulative readings of a real-world-like meter: jittered cadence, unaligned stamps.
Home Assistant style meters report whenever they change, so neither the first
reading nor any later reading falls on a slot boundary. The meter measures
``bias`` times the modelled power; the stamps carry ``timezone``.
"""
row_start = pd.DatetimeIndex(frame.index)
row_length = row_start[1] - row_start[0]
if not interval_start_labels:
row_start = row_start - row_length
epoch = pd.Timestamp(0, tz="UTC")
energy_kwh = frame["ac_power"].to_numpy(dtype=float) * row_length.total_seconds() / 3600.0
# Cumulative energy at every row boundary, interpolated to the meter stamps.
boundaries = pd.DatetimeIndex([*row_start, row_start[-1] + row_length]) - epoch
cumulative = np.concatenate([[0.0], np.cumsum(energy_kwh * bias / 1000.0)])
jitter = [0, 21, 47, 13, 34]
stamps = []
stamp = _utc_timestamp(first)
end = _utc_timestamp(until)
while stamp < end:
stamps.append(stamp)
stamp += pd.Timedelta(minutes=cadence_minutes, seconds=jitter[len(stamps) % len(jitter)])
index = pd.DatetimeIndex(stamps)
values = np.interp(
(index - epoch).total_seconds(), boundaries.total_seconds(), cumulative
).round(3)
return pd.Series(values, index=index.tz_convert(timezone))
async def _feed_meters(instance: PVForecastAkkudoktorLocal, meters: dict[str, pd.Series]) -> None:
"""Configure ``meters`` as the PV production meters and store their readings."""
instance.config.measurement.pv_production_emr_keys = list(meters)
measurement = get_measurement()
for key, series in meters.items():
await measurement.key_from_series(key, series)
@pytest.fixture
def recorded_windows(monkeypatch) -> list[tuple[DateTime, DateTime]]:
"""Record the (start, end) of every PV production energy query."""
windows: list[tuple[DateTime, DateTime]] = []
production_total_kwh = PVForecastAkkudoktorLocal._pv_production_total_kwh
async def recording_production_total_kwh(self, start_datetime, end_datetime, interval):
windows.append((start_datetime, end_datetime))
return await production_total_kwh(self, start_datetime, end_datetime, interval)
monkeypatch.setattr(
PVForecastAkkudoktorLocal, "_pv_production_total_kwh", recording_production_total_kwh
)
return windows
def _calibration_settings(**overrides: Any) -> PVForecastAkkudoktorLocalCommonSettings:
"""Calibration over 30 days with 45-degree azimuth bins.
The bins expose a slot shift between measured and modelled energy: on a clear-sky
day a shift lowers the morning bins and raises the evening ones (or the reverse),
while the global factor barely moves.
"""
settings: dict[str, Any] = {
"calibration_enabled": True,
"calibration_days": 30,
"calibration_reference_days": 30,
"calibration_azimuth_bin_degrees": 45,
**overrides,
}
return PVForecastAkkudoktorLocalCommonSettings(**settings)
def _assert_fitted_bias(
calibration: Optional[tuple[float, np.ndarray]], bias: float, cadence_minutes: int = 5
) -> None:
"""The global factor and every azimuth-bin factor recover the meter bias.
An hourly meter is interpolated linearly across the curved dawn and dusk
production, which moves those bins by a few percent in the same direction;
a slot shift would move east and west bins in opposite directions.
"""
assert calibration is not None
global_factor, factors = calibration
assert global_factor == pytest.approx(bias, abs=0.01)
np.testing.assert_allclose(factors, bias, atol=0.02 if cadence_minutes <= 15 else 0.05)
@pytest.mark.asyncio
@pytest.mark.parametrize(
("timezone", "first", "cadence_minutes", "interval_minutes", "expected_start"),
[
pytest.param(
"UTC", "2025-06-09T00:04:50Z", 5, 15, "2025-06-09T00:15:00Z", id="meter-start-15min"
),
pytest.param(
"Asia/Kathmandu",
"2025-06-09T00:04:50Z",
5,
15,
"2025-06-09T00:15:00Z",
id="meter-start-15min-offset-zone",
),
pytest.param(
"Asia/Kathmandu",
"2025-06-09T00:04:50Z",
60,
60,
"2025-06-09T01:00:00Z",
id="meter-start-hourly-offset-zone",
),
pytest.param(
"UTC", "2025-05-31T20:04:50Z", 5, 15, "2025-05-31T23:45:00Z", id="model-start-15min"
),
],
)
async def test_calibration_with_short_unaligned_meter_history(
pvforecast_instance,
recorded_windows,
timezone: str,
first: str,
cadence_minutes: int,
interval_minutes: int,
expected_start: str,
):
"""A PV meter younger than the lookback window must still be fitted.
Regression: the window start was taken from the first PV reading (e.g. 00:04:50)
without snapping it to the slot grid, so the model grid (00:19:50, 00:34:50, ...)
never hit a resampled model row and every interval was discarded as NaN. The
window must start at the first slot the readings fully cover and hold whole
slots on the UTC grid, also in zones with a quarter-hour offset, and measured
and modelled energy must line up slot by slot.
"""
pvforecast_instance.config.merge_settings_from_dict(
{"general": {"timezone_override": timezone}}
)
assert pvforecast_instance.config.general.timezone == timezone
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(
frame, 0.8, to_datetime(first), START, cadence_minutes, timezone=timezone
)
await _feed_meters(pvforecast_instance, {f"pv_unaligned_emr_{cadence_minutes}": meter})
calibration = await _fit(pvforecast_instance, frame)
_assert_fitted_bias(calibration, 0.8, cadence_minutes)
start, end = recorded_windows[0]
assert compare_datetimes(start, to_datetime(expected_start)).equal
slot_seconds = interval_minutes * 60
assert start.timestamp() % slot_seconds == 0
assert end.timestamp() % slot_seconds == 0
@pytest.mark.asyncio
async def test_calibration_bins_interval_end_labels_by_interval_start(pvforecast_instance):
"""With ``shift_to_interval_start=False`` the rows keep Open-Meteo's end stamps.
Each row still covers the interval before its label, so the fit must bin it into
the meter slot of that interval, not into the next one.
"""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(
shift_to_interval_start=False
)
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(
frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5, interval_start_labels=False
)
await _feed_meters(pvforecast_instance, {"pv_end_labels_emr": meter})
calibration = await _fit(pvforecast_instance, frame)
_assert_fitted_bias(calibration, 0.8)
@pytest.mark.asyncio
async def test_calibration_window_is_common_to_all_pv_meters(
pvforecast_instance, recorded_windows
):
"""Every PV meter must cover the window; one meter alone does not count.
Meter A runs the whole period, meter B starts later and stops earlier. The fit
may only use the period both report, which is also where their sum is the plant.
"""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter_a = _unaligned_meter_series(frame, 0.4, to_datetime("2025-06-09T00:04:50Z"), START, 5)
meter_b = _unaligned_meter_series(
frame, 0.4, to_datetime("2025-06-11T03:02:10Z"), to_datetime("2025-06-13T20:00:00Z"), 5
)
await _feed_meters(pvforecast_instance, {"pv_common_a_emr": meter_a, "pv_common_b_emr": meter_b})
calibration = await _fit(pvforecast_instance, frame)
_assert_fitted_bias(calibration, 0.8)
start, end = recorded_windows[0]
assert compare_datetimes(start, to_datetime("2025-06-11T03:15:00Z")).equal
assert compare_datetimes(end, to_datetime("2025-06-13T19:45:00Z")).equal
@pytest.mark.asyncio
async def test_forecast_reads_the_pv_meter_window_once(pvforecast_instance, monkeypatch):
"""Calibration and snow feedback share one scan of the PV meter readings."""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(snow_enabled=True)
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
await _feed_meters(pvforecast_instance, {"pv_read_once_emr": meter})
reads = 0
measurement_window = PVForecastAkkudoktorLocal._pv_measurement_window
async def counting_measurement_window(self):
nonlocal reads
reads += 1
return await measurement_window(self)
monkeypatch.setattr(
PVForecastAkkudoktorLocal, "_pv_measurement_window", counting_measurement_window
)
await pvforecast_instance._forecast_frame(synthetic_openmeteo())
assert reads == 1
@pytest.mark.asyncio
async def test_snow_feedback_window_is_on_the_slot_grid(pvforecast_instance, recorded_windows):
"""Snow feedback compares the same whole UTC slots as the calibration fit."""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(
calibration_enabled=False, snow_lookback_days=7
)
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
await _feed_meters(pvforecast_instance, {"pv_snow_window_emr": meter})
pv_window = await pvforecast_instance._pv_measurement_window()
assert pv_window is not None
observations, interval_hours = await pvforecast_instance._snow_observations(frame, pv_window)
assert interval_hours == 0.25
assert observations
start, end = recorded_windows[0]
assert compare_datetimes(start, to_datetime("2025-06-09T00:15:00Z")).equal
# The end is the last slot boundary before the last reading.
assert end.timestamp() % 900 == 0
assert compare_datetimes(end, pv_window.last).le