fix(genetic): keep a started home appliance run until the device reports it finished
A re-plan treated a running home appliance as not started. In its start slot it could pick another start of equal cost and switch the appliance off; after the start slot it could only plan a new complete run later; and when no complete run fitted into the rest of the window, the DAILY cycle was dropped and the running appliance got OFF. The executor now reports the start of a planned run as UNIX seconds under `<device_id>.run_started_at` (setting `run_started_measurement_key`) and 0 when the device reports the run as finished. The device decides when that is, also before or after the configured duration. Until then the GENETIC optimizer places the remaining energy from now on as fixed load, independent of windows, deadline and genes, sends RUN, counts the run as a cycle of its start day and plans further cycles after its end and gap. A run past its duration keeps the current slot without extra energy; a start more than two run durations ago, or an invalid value, is logged and ignored. Refs: #1548 Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com> Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
committed by
Bobby Noelte
co-authored by
Claude Opus 5.5
parent
0bf9f50b97
commit
4693e1fa97
@@ -512,6 +512,22 @@ the measurement store, under the key configured in `cycles_completed_measurement
|
||||
to `{device_id}.cycles_completed`). This lets the optimizer skip cycles the appliance has already
|
||||
completed earlier the same day.
|
||||
|
||||
A run that has started is kept until the device reports it as finished. The executor writes the
|
||||
start of the run as UNIX time in seconds to the key configured in `run_started_measurement_key`
|
||||
(defaults to `{device_id}.run_started_at`) when it switches the appliance on for a planned run.
|
||||
When the device reports the run as finished, the executor writes `0` and increments the completed
|
||||
cycles. The device decides when that is: a water heater may finish early because its thermostat
|
||||
reached the temperature, a dishwasher may run longer than its profile. Until then, every re-plan:
|
||||
|
||||
- places the remaining energy of the run from now on, independent of time windows and deadline,
|
||||
- sends RUN for the appliance and does not move or stop the run,
|
||||
- counts the run as a cycle of its start day and plans further cycles after its end and
|
||||
`min_cycle_gap_h`.
|
||||
|
||||
A run past its configured duration keeps the current slot without extra energy. A start more than
|
||||
two run durations ago is taken as a stale report and ignored, as are invalid values; both are
|
||||
logged.
|
||||
|
||||
:::{admonition} Note
|
||||
:class: note
|
||||
Unlike GENETIC0, the GENETIC algorithm can plan multiple cycles -- and therefore multiple starts
|
||||
|
||||