mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-10-29 09:11:57 +00:00
fix(adapter): stamp Home Assistant device states with run time, not slot start (#1452)
* fix(adapter): stamp Home Assistant device states with run time, not slot start The Home Assistant adapter stored every reading with ems_start_datetime, which set_start_datetime() rounds down to the optimization slot (e.g. 14:00 for a run at 14:11). The GENETIC configuration request checks SoC freshness against the unrounded observation_datetime with measurement_max_age_seconds (default 300 s). Any run starting more than five minutes into a slot therefore discarded the freshly read SoC and optimized with 0 % initial SoC. Stamp device state measurements (device_measurement_entity_ids, e.g. SoC) with observation_datetime instead. Not to_datetime(): a reading taken a few seconds after the observation time would be rejected as a future sample. Meter readings (load, grid import/export, PV) keep the slot start, because their energy is aggregated per slot. With device states at their real time, a record holding only some keys can now be the newest one (e.g. the Home Assistant battery SoC while the EV SoC or a cycle count comes through the measurement API). Readers therefore skip records without the value they need: - GENETIC SoC and completed appliance cycles: such a record no longer hides a fresh value (the cycle count case aborted the optimization). This also covers a meter reading at the slot start that is newer than a SoC supplied through the measurement API. Values stored as pandas NA count as missing instead of raising TypeError; an explicit NaN stays an invalid sample. - GENETIC0 SoC: looks up the reading nearest to observation_datetime instead of the slot start, skipping records without SoC and converting only the selected sample. Before, a run late in the slot (14:40 in the 14:00 slot) would pick the previous run's reading (13:40). This also fixes SoC values PUT via the REST API with their real time. LoadAkkudoktorAdjusted anchored its hourly comparison window on the newest record of any key. An off-hour device state would shift every bucket (e.g. to :11) against hour-aligned meter readings; the window now starts and ends on full hours, and less than one full hour of data yields no adjustment instead of an error. (15-minute slot starts and SoC values PUT with their real time had the same effect before.) Regenerated openapi.json and docs/_generated/openapi.md (version only). Fixes #1447 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01EYWR1HVM8a8src23xuyL3T * test(genetic0): use pv_battery instead of deprecated pv_akku mypy flags attribute access on the pv_akku computed field (attr-defined), which failed the pre-commit check of the PR. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01EYWR1HVM8a8src23xuyL3T --------- Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
5249b389f5
commit
58b968562e
@@ -1,6 +1,6 @@
|
||||
# Akkudoktor-EOS
|
||||
|
||||
**Version**: `v0.3.0.dev2610201560628681`
|
||||
**Version**: `v0.3.0.dev2610251221711267`
|
||||
|
||||
<!-- pyml disable line-length -->
|
||||
**Description**: This project provides a comprehensive solution for simulating and optimizing an energy system based on renewable energy sources. With a focus on photovoltaic (PV) systems, battery storage (batteries), load management (consumer requirements), heat pumps, electric vehicles, and consideration of electricity price data, this system enables forecasting and optimization of energy flow and costs over a specified period.
|
||||
|
||||
Reference in New Issue
Block a user