mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-03-18 04:26:18 +00:00
fix: genetic optimizer charge rates, SoC accuracy, and minor bugfixes (#949)
Some checks failed
Bump Version / Bump Version Workflow (push) Has been cancelled
CodeQL Advanced / Analyze (actions) (push) Has been cancelled
CodeQL Advanced / Analyze (python) (push) Has been cancelled
docker-build / platform-excludes (push) Has been cancelled
docker-build / build (push) Has been cancelled
docker-build / merge (push) Has been cancelled
pre-commit / pre-commit (push) Has been cancelled
Run Pytest on Pull Request / test (push) Has been cancelled
Some checks failed
Bump Version / Bump Version Workflow (push) Has been cancelled
CodeQL Advanced / Analyze (actions) (push) Has been cancelled
CodeQL Advanced / Analyze (python) (push) Has been cancelled
docker-build / platform-excludes (push) Has been cancelled
docker-build / build (push) Has been cancelled
docker-build / merge (push) Has been cancelled
pre-commit / pre-commit (push) Has been cancelled
Run Pytest on Pull Request / test (push) Has been cancelled
* record battery SOC at the start of the interval for accurate display
* map battery charge rates to GeneticOptimizationParameters and update related logic
Instead of using the EV charge rates, the battery now has its own charge rate defined
in the GeneticOptimizationParameters to better separate those entities.
* separate raw gene values from SOC-clamped op factors
The genetic_*_factor columns in the OptimizationSolution dataframe now
always carry the raw gene values (optimizer intent), while the
battery1_*_op_mode / battery1_*_op_factor columns and FRBCInstruction
operation_mode_factor reflect SOC-clamped effective values that can
actually be executed given the battery's state of charge at each hour.
Adds GeneticSolution._soc_clamped_operation_factors():
- AC charge factor: proportionally scaled down when battery headroom
(max_soc - current_soc) is less than what the commanded factor
would store in one hour; zeroed when battery is full.
- DC charge factor: zeroed when battery is at or above max SOC.
- Discharge: blocked when SOC is at or below min SOC.
Both optimization_solution() and energy_management_plan() pass the
clamped values to _battery_operation_from_solution(), so the plan
instructions the HEMS receives reflect physically achievable targets.
* ensure max AC charge power is only used if defined
* update fixtures for PV suffix + SOC-clamp algorithm changes
* handle None case for home appliance start hour in simulation
if the hour is zero, the the home appliance wont start
* update handling of invalid charge indices in autocharge hours
Seems to be a bug, since all invalid indexes needs to be invalidated (also the first one)
* remove double code in simulation preparation and improve comments
* update version
Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
Co-authored-by: Christopher Nadler <christopher.nadler@gmail.com>
This commit is contained in:
@@ -6,7 +6,7 @@
|
||||
# the root directory (no add-on folder as usual).
|
||||
|
||||
name: "Akkudoktor-EOS"
|
||||
version: "0.2.0.dev2603140879799190"
|
||||
version: "0.2.0.dev2603160842907888"
|
||||
slug: "eos"
|
||||
description: "Akkudoktor-EOS add-on"
|
||||
url: "https://github.com/Akkudoktor-EOS/EOS"
|
||||
|
||||
Reference in New Issue