diff --git a/docs/_generated/configdevices.md b/docs/_generated/configdevices.md index a788239e..2fe29f7e 100644 --- a/docs/_generated/configdevices.md +++ b/docs/_generated/configdevices.md @@ -209,7 +209,7 @@ | ac_to_dc_efficiency | `float` | `rw` | `1.0` | Efficiency of AC to DC conversion for grid-to-battery AC charging (0-1). Set to 0 to disable AC charging. Default 1.0 (no additional inverter loss). | | battery_id | `str | None` | `rw` | `None` | ID of battery controlled by this inverter. | | dc_to_ac_efficiency | `float` | `rw` | `1.0` | Efficiency of DC to AC conversion for battery discharging to AC load/grid (0-1). Default 1.0 (no additional inverter loss). | -| device_id | `str` | `rw` | `` | ID of device | +| device_id | `str` | `rw` | `required` | ID of device | | max_ac_charge_power_w | `float | None` | `rw` | `None` | Maximum AC charging power in watts. null means no additional limit. Set to 0 to disable AC charging. | | max_power_w | `float | None` | `rw` | `None` | Maximum power [W]. | | measurement_keys | `list[str] | None` | `ro` | `N/A` | Measurement keys for the inverter stati that are measurements. | @@ -372,7 +372,7 @@ as a cohesive unit for scheduling and availability checking. | Name | Type | Read-Only | Default | Description | | ---- | ---- | --------- | ------- | ----------- | | consumption_wh | `int` | `rw` | `required` | Energy consumption [Wh]. | -| device_id | `str` | `rw` | `` | ID of device | +| device_id | `str` | `rw` | `required` | ID of device | | duration_h | `int` | `rw` | `required` | Usage duration in hours [0 ... 24]. | | measurement_keys | `list[str] | None` | `ro` | `N/A` | Measurement keys for the home appliance stati that are measurements. | | time_windows | `akkudoktoreos.config.configabc.TimeWindowSequence | None` | `rw` | `None` | Sequence of allowed time windows. Defaults to optimization general time window. | @@ -454,7 +454,7 @@ as a cohesive unit for scheduling and availability checking. | capacity_wh | `int` | `rw` | `8000` | Capacity [Wh]. | | charge_rates | `list[float] | None` | `rw` | `[0.0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0]` | Charge rates as factor of maximum charging power [0.00 ... 1.00]. None triggers fallback to default charge-rates. | | charging_efficiency | `float` | `rw` | `0.88` | Charging efficiency [0.01 ... 1.00]. | -| device_id | `str` | `rw` | `` | ID of device | +| device_id | `str` | `rw` | `required` | ID of device | | discharging_efficiency | `float` | `rw` | `0.88` | Discharge efficiency [0.01 ... 1.00]. | | levelized_cost_of_storage_kwh | `float` | `rw` | `0.0` | Levelized cost of storage (LCOS), the average lifetime cost of delivering one kWh [amount/kWh]. | | max_charge_power_w | `float | None` | `rw` | `5000` | Maximum charging power [W]. | diff --git a/docs/_generated/configems.md b/docs/_generated/configems.md index 5d6ab1e9..10343912 100644 --- a/docs/_generated/configems.md +++ b/docs/_generated/configems.md @@ -8,13 +8,14 @@ | Name | Environment Variable | Type | Read-Only | Default | Description | | ---- | -------------------- | ---- | --------- | ------- | ----------- | | interval | `EOS_EMS__INTERVAL` | `float` | `rw` | `300.0` | Intervall between EOS energy management runs [seconds]. | -| mode | `EOS_EMS__MODE` | `` | `rw` | `required` | Energy management mode [DISABLED | OPTIMIZATION | PREDICTION]. | +| mode | `EOS_EMS__MODE` | `` | `rw` | `required` | Energy management mode [DISABLED | PREDICTION | OPTIMIZATION]. Defaults to DISABLED. | +| modes | | `list[str]` | `ro` | `N/A` | Available energy management modes. | | startup_delay | `EOS_EMS__STARTUP_DELAY` | `float` | `rw` | `5` | Startup delay in seconds for EOS energy management runs. | ::: -**Example Input/Output** +**Example Input** @@ -28,3 +29,24 @@ } ``` + + +**Example Output** + + + +```json + { + "ems": { + "startup_delay": 5.0, + "interval": 300.0, + "mode": "OPTIMIZATION", + "modes": [ + "DISABLED", + "PREDICTION", + "OPTIMIZATION" + ] + } + } +``` + diff --git a/docs/_generated/configexample.md b/docs/_generated/configexample.md index 235d803c..e48fe468 100644 --- a/docs/_generated/configexample.md +++ b/docs/_generated/configexample.md @@ -217,6 +217,7 @@ "token": "your-token", "site_id": 12345 }, + "pvlib": {}, "pvnode": { "api_key": "", "site_id": null, diff --git a/docs/_generated/configload.md b/docs/_generated/configload.md index 157e8c32..81e106d0 100644 --- a/docs/_generated/configload.md +++ b/docs/_generated/configload.md @@ -63,8 +63,8 @@ "providers": [ "LoadAkkudoktor", "LoadAkkudoktorAdjusted", - "LoadVrm", - "LoadImport" + "LoadImport", + "LoadVrm" ] } } diff --git a/docs/_generated/configoptimization.md b/docs/_generated/configoptimization.md index 11c85e72..b12c58fe 100644 --- a/docs/_generated/configoptimization.md +++ b/docs/_generated/configoptimization.md @@ -7,7 +7,7 @@ | Name | Environment Variable | Type | Read-Only | Default | Description | | ---- | -------------------- | ---- | --------- | ------- | ----------- | -| algorithm | `EOS_OPTIMIZATION__ALGORITHM` | `str` | `rw` | `GENETIC` | The optimization algorithm. Defaults to GENETIC | +| algorithm | `EOS_OPTIMIZATION__ALGORITHM` | `` | `rw` | `required` | Optimization algorithm [GENETIC | GENETIC0]. Defaults to GENETIC. | | algorithms | | `list[str]` | `ro` | `N/A` | Available optimization algorithms. | | genetic | `EOS_OPTIMIZATION__GENETIC` | `GeneticCommonSettings` | `rw` | `required` | GENETIC optimization algorithm configuration. | | genetic0 | `EOS_OPTIMIZATION__GENETIC0` | `Genetic0CommonSettings` | `rw` | `required` | GENETIC0 optimization algorithm configuration. | diff --git a/docs/_generated/configpvforecast.md b/docs/_generated/configpvforecast.md index bd8a75e6..cd9fddab 100644 --- a/docs/_generated/configpvforecast.md +++ b/docs/_generated/configpvforecast.md @@ -18,6 +18,7 @@ | provider | `EOS_PVFORECAST__PROVIDER` | `str | None` | `rw` | `None` | PVForecast provider id of provider to be used. | | providers | | `list[str]` | `ro` | `N/A` | Available PVForecast provider ids. | | pvforecastimport | `EOS_PVFORECAST__PVFORECASTIMPORT` | `PVForecastImportCommonSettings` | `rw` | `required` | PV forecast import provider settings | +| pvlib | `EOS_PVFORECAST__PVLIB` | `PVForecastPVLibCommonSettings` | `rw` | `required` | PVLib provider settings | | pvnode | `EOS_PVFORECAST__PVNODE` | `PVForecastPVNodeCommonSettings` | `rw` | `required` | PVNode provider settings | | solcast | `EOS_PVFORECAST__SOLCAST` | `PVForecastSolcastCommonSettings` | `rw` | `required` | Solcast provider settings | | vrm | `EOS_PVFORECAST__VRM` | `PVForecastVrmCommonSettings` | `rw` | `required` | Victron Remote Management (VRM) provider settings | @@ -41,6 +42,7 @@ "token": "your-token", "site_id": 12345 }, + "pvlib": {}, "pvnode": { "api_key": "", "site_id": null, @@ -122,6 +124,7 @@ "token": "your-token", "site_id": 12345 }, + "pvlib": {}, "pvnode": { "api_key": "", "site_id": null, @@ -183,11 +186,12 @@ "max_planes": 1, "providers": [ "PVForecastAkkudoktor", - "PVForecastVrm", - "PVForecastPVNode", "PVForecastForecastSolar", + "PVForecastImport", + "PVForecastPVLib", + "PVForecastPVNode", "PVForecastSolcast", - "PVForecastImport" + "PVForecastVrm" ], "planes_peakpower": [ 5.0, @@ -317,6 +321,32 @@ ``` +### Common settings for pvforecast data calculation with PVLib + + +:::{table} pvforecast::pvlib +:widths: 10 10 5 5 30 +:align: left + +| Name | Type | Read-Only | Default | Description | +| ---- | ---- | --------- | ------- | ----------- | +::: + + + +**Example Input/Output** + + + +```json + { + "pvforecast": { + "pvlib": {} + } + } +``` + + ### Common settings for pvforecast data import from file or JSON string @@ -357,13 +387,13 @@ | Name | Type | Read-Only | Default | Description | | ---- | ---- | --------- | ------- | ----------- | -| albedo | `float | None` | `rw` | `None` | Proportion of the light hitting the ground that it reflects back. | +| albedo | `float | None` | `rw` | `0.2` | Proportion of the light hitting the ground that it reflects back. | | inverter_model | `str | None` | `rw` | `None` | Model of the inverter of this plane. | | inverter_paco | `int | None` | `rw` | `None` | AC power rating of the inverter [W]. | | loss | `float | None` | `rw` | `14.0` | Sum of PV system losses in percent | | module_model | `str | None` | `rw` | `None` | Model of the PV modules of this plane. | | modules_per_string | `int | None` | `rw` | `None` | Number of the PV modules of the strings of this plane. | -| mountingplace | `str | None` | `rw` | `free` | Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated. | +| mountingplace | `str | None` | `rw` | `building` | Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated. | | optimal_surface_tilt | `bool | None` | `rw` | `False` | Calculate the optimum tilt angle. Ignored for two-axis tracking. | | optimalangles | `bool | None` | `rw` | `False` | Calculate the optimum tilt and azimuth angles. Ignored for two-axis tracking. | | peakpower | `float | None` | `rw` | `None` | Nominal power of PV system in kW. | @@ -395,7 +425,7 @@ ], "peakpower": 5.0, "pvtechchoice": "crystSi", - "mountingplace": "free", + "mountingplace": "building", "loss": 14.0, "trackingtype": 0, "optimal_surface_tilt": false, diff --git a/docs/_generated/configweather.md b/docs/_generated/configweather.md index 02c94603..ec7d3e05 100644 --- a/docs/_generated/configweather.md +++ b/docs/_generated/configweather.md @@ -47,8 +47,8 @@ "providers": [ "BrightSky", "ClearOutside", - "OpenMeteo", - "WeatherImport" + "WeatherImport", + "OpenMeteo" ] } } diff --git a/docs/_generated/openapi.md b/docs/_generated/openapi.md index 4a842abb..e43e338a 100644 --- a/docs/_generated/openapi.md +++ b/docs/_generated/openapi.md @@ -1,6 +1,6 @@ # Akkudoktor-EOS -**Version**: `v0.3.0.dev2608010961051894` +**Version**: `v0.3.0.dev2608071015082558` **Description**: This project provides a comprehensive solution for simulating and optimizing an energy system based on renewable energy sources. With a focus on photovoltaic (PV) systems, battery storage (batteries), load management (consumer requirements), heat pumps, electric vehicles, and consideration of electricity price data, this system enables forecasting and optimization of energy flow and costs over a specified period. @@ -1464,6 +1464,50 @@ Args: --- +## GET /v1/prediction/pvforecast/pvlib/inverters + + +**Links**: [local](http://localhost:8503/docs#/default/fastapi_prediction_pvforecast_inverters_get_v1_prediction_pvforecast_pvlib_inverters_get), [eos](https://petstore3.swagger.io/?url=https://raw.githubusercontent.com/Akkudoktor-EOS/EOS/refs/heads/main/openapi.json#/default/fastapi_prediction_pvforecast_inverters_get_v1_prediction_pvforecast_pvlib_inverters_get) + + +Fastapi Prediction Pvforecast Inverters Get + + +```python +""" +Get inverter names supported by PVForecast PVLib provider. +""" +``` + + +**Responses**: + +- **200**: Successful Response + +--- + +## GET /v1/prediction/pvforecast/pvlib/modules + + +**Links**: [local](http://localhost:8503/docs#/default/fastapi_prediction_pvforecast_modules_get_v1_prediction_pvforecast_pvlib_modules_get), [eos](https://petstore3.swagger.io/?url=https://raw.githubusercontent.com/Akkudoktor-EOS/EOS/refs/heads/main/openapi.json#/default/fastapi_prediction_pvforecast_modules_get_v1_prediction_pvforecast_pvlib_modules_get) + + +Fastapi Prediction Pvforecast Modules Get + + +```python +""" +Get module names supported by PVForecast PVLib provider. +""" +``` + + +**Responses**: + +- **200**: Successful Response + +--- + ## DELETE /v1/prediction/range diff --git a/docs/akkudoktoreos/prediction.md b/docs/akkudoktoreos/prediction.md index 5583c3f3..319d2d03 100644 --- a/docs/akkudoktoreos/prediction.md +++ b/docs/akkudoktoreos/prediction.md @@ -693,6 +693,30 @@ The PV forecast data must be provided in one of the formats described in The data may additionally or solely be provided by the **PUT** `/v1/prediction/import/PVForecastImport` endpoint. +### PVForecastPVLib Provider + +The `PVForecastPVLib` provider calculates PV power forecasts locally using the +[PVLib](https://pvlib-python.readthedocs.io/) simulation library. Unlike the +API-based providers, no external forecast service is required. The provider +uses the configured PV system geometry together with the weather prediction +(`weather_ghi`, `weather_dni`, `weather_dhi`, `weather_temp_air`, etc.) to +simulate the expected DC module power and AC inverter output. + +The provider supports multiple PV planes and automatically sums their power. +Module and inverter models are selected from the CEC database by name or by +their nominal power rating. AkkudoktorEOS automatically generates and caches +the required CEC databases on first use by combining the current SAM database, +legacy PVLib entries, and the additional EMHASS models. + +The following prediction keys are provided: + +- `pvforecast_ac_power`: Total AC power (W). +- `pvforecast_dc_power`: Total DC power (W). + +Currently, the configuration options `userhorizon`, `optimalangles`, and +tracking systems (`trackingtype != 0`) are ignored. If no `albedo` is +configured, a default value of `0.2` is used. + ### PVForecastPVNode Provider The `PVForecastPVNode` provider retrieves native 15-minute PV power forecasts from the diff --git a/openapi.json b/openapi.json index bacc9852..4b65ea27 100644 --- a/openapi.json +++ b/openapi.json @@ -8,7 +8,7 @@ "name": "Apache 2.0", "url": "https://www.apache.org/licenses/LICENSE-2.0.html" }, - "version": "v0.3.0.dev2608010961051894" + "version": "v0.3.0.dev2608071015082558" }, "paths": { "/v1/admin/cache/clear": { @@ -2391,6 +2391,58 @@ } } }, + "/v1/prediction/pvforecast/pvlib/modules": { + "get": { + "tags": [ + "prediction" + ], + "summary": "Fastapi Prediction Pvforecast Modules Get", + "description": "Get module names supported by PVForecast PVLib provider.", + "operationId": "fastapi_prediction_pvforecast_modules_get_v1_prediction_pvforecast_pvlib_modules_get", + "responses": { + "200": { + "description": "Successful Response", + "content": { + "application/json": { + "schema": { + "items": { + "type": "string" + }, + "type": "array", + "title": "Response Fastapi Prediction Pvforecast Modules Get V1 Prediction Pvforecast Pvlib Modules Get" + } + } + } + } + } + } + }, + "/v1/prediction/pvforecast/pvlib/inverters": { + "get": { + "tags": [ + "prediction" + ], + "summary": "Fastapi Prediction Pvforecast Inverters Get", + "description": "Get inverter names supported by PVForecast PVLib provider.", + "operationId": "fastapi_prediction_pvforecast_inverters_get_v1_prediction_pvforecast_pvlib_inverters_get", + "responses": { + "200": { + "description": "Successful Response", + "content": { + "application/json": { + "schema": { + "items": { + "type": "string" + }, + "type": "array", + "title": "Response Fastapi Prediction Pvforecast Inverters Get V1 Prediction Pvforecast Pvlib Inverters Get" + } + } + } + } + } + } + }, "/v1/energy-management/optimization/solution": { "get": { "tags": [ @@ -2427,8 +2479,7 @@ "in": "path", "required": true, "schema": { - "type": "string", - "title": "Algorithm" + "$ref": "#/components/schemas/OptimizationAlgorithm" } } ], @@ -2828,7 +2879,6 @@ "type": "string", "title": "Device Id", "description": "ID of device", - "default": "", "examples": [ "battery1", "ev1", @@ -2982,7 +3032,6 @@ "type": "string", "title": "Device Id", "description": "ID of device", - "default": "", "examples": [ "battery1", "ev1", @@ -3242,7 +3291,7 @@ "$ref": "#/components/schemas/DatabaseCommonSettings-Output" }, "ems": { - "$ref": "#/components/schemas/EnergyManagementCommonSettings" + "$ref": "#/components/schemas/EnergyManagementCommonSettings-Output" }, "logging": { "$ref": "#/components/schemas/LoggingCommonSettings-Output" @@ -4524,7 +4573,7 @@ "title": "EnergyChartsBiddingZones", "description": "Energy Charts Bidding Zones." }, - "EnergyManagementCommonSettings": { + "EnergyManagementCommonSettings-Input": { "properties": { "startup_delay": { "type": "number", @@ -4545,10 +4594,9 @@ }, "mode": { "$ref": "#/components/schemas/EnergyManagementMode", - "description": "Energy management mode [DISABLED | OPTIMIZATION | PREDICTION].", + "description": "Energy management mode [DISABLED | PREDICTION | OPTIMIZATION]. Defaults to DISABLED.", "examples": [ - "OPTIMIZATION", - "PREDICTION" + "OPTIMIZATION" ] } }, @@ -4556,6 +4604,49 @@ "title": "EnergyManagementCommonSettings", "description": "Energy Management Configuration." }, + "EnergyManagementCommonSettings-Output": { + "properties": { + "startup_delay": { + "type": "number", + "minimum": 1.0, + "title": "Startup Delay", + "description": "Startup delay in seconds for EOS energy management runs.", + "default": 5 + }, + "interval": { + "type": "number", + "minimum": 60.0, + "title": "Interval", + "description": "Intervall between EOS energy management runs [seconds].", + "default": 300.0, + "examples": [ + "300" + ] + }, + "mode": { + "$ref": "#/components/schemas/EnergyManagementMode", + "description": "Energy management mode [DISABLED | PREDICTION | OPTIMIZATION]. Defaults to DISABLED.", + "examples": [ + "OPTIMIZATION" + ] + }, + "modes": { + "items": { + "type": "string" + }, + "type": "array", + "title": "Modes", + "description": "Available energy management modes.", + "readOnly": true + } + }, + "type": "object", + "required": [ + "modes" + ], + "title": "EnergyManagementCommonSettings", + "description": "Energy Management Configuration." + }, "EnergyManagementMode": { "type": "string", "enum": [ @@ -8181,7 +8272,6 @@ "type": "string", "title": "Device Id", "description": "ID of device", - "default": "", "examples": [ "battery1", "ev1", @@ -8244,7 +8334,6 @@ "type": "string", "title": "Device Id", "description": "ID of device", - "default": "", "examples": [ "battery1", "ev1", @@ -8782,7 +8871,6 @@ "type": "string", "title": "Device Id", "description": "ID of device", - "default": "", "examples": [ "battery1", "ev1", @@ -8876,7 +8964,6 @@ "type": "string", "title": "Device Id", "description": "ID of device", - "default": "", "examples": [ "battery1", "ev1", @@ -9781,13 +9868,20 @@ "title": "OMBCStatus", "description": "Reports the current operational status of an Operation Mode Based Control system.\n\nThis model provides real-time status information about an OMBC-controlled device,\nincluding which operation mode is currently active, how it is configured,\nand information about recent mode transitions. It enables monitoring of the\ndevice's operational state and tracking mode transition history." }, + "OptimizationAlgorithm": { + "type": "string", + "enum": [ + "GENETIC", + "GENETIC0" + ], + "title": "OptimizationAlgorithm", + "description": "Optimization Algorithm." + }, "OptimizationCommonSettings-Input": { "properties": { "algorithm": { - "type": "string", - "title": "Algorithm", - "description": "The optimization algorithm. Defaults to GENETIC", - "default": "GENETIC", + "$ref": "#/components/schemas/OptimizationAlgorithm", + "description": "Optimization algorithm [GENETIC | GENETIC0]. Defaults to GENETIC.", "examples": [ "GENETIC", "GENETIC0" @@ -9825,10 +9919,8 @@ "OptimizationCommonSettings-Output": { "properties": { "algorithm": { - "type": "string", - "title": "Algorithm", - "description": "The optimization algorithm. Defaults to GENETIC", - "default": "GENETIC", + "$ref": "#/components/schemas/OptimizationAlgorithm", + "description": "Optimization algorithm [GENETIC | GENETIC0]. Defaults to GENETIC.", "examples": [ "GENETIC", "GENETIC0" @@ -10412,6 +10504,10 @@ "$ref": "#/components/schemas/PVForecastVrmCommonSettings", "description": "Victron Remote Management (VRM) provider settings" }, + "pvlib": { + "$ref": "#/components/schemas/PVForecastPVLibCommonSettings", + "description": "PVLib provider settings" + }, "pvnode": { "$ref": "#/components/schemas/PVForecastPVNodeCommonSettings", "description": "PVNode provider settings" @@ -10529,6 +10625,10 @@ "$ref": "#/components/schemas/PVForecastVrmCommonSettings", "description": "Victron Remote Management (VRM) provider settings" }, + "pvlib": { + "$ref": "#/components/schemas/PVForecastPVLibCommonSettings", + "description": "PVLib provider settings" + }, "pvnode": { "$ref": "#/components/schemas/PVForecastPVNodeCommonSettings", "description": "PVNode provider settings" @@ -10740,6 +10840,12 @@ "title": "PVForecastImportCommonSettings", "description": "Common settings for pvforecast data import from file or JSON string." }, + "PVForecastPVLibCommonSettings": { + "properties": {}, + "type": "object", + "title": "PVForecastPVLibCommonSettings", + "description": "Common settings for pvforecast data calculation with PVLib." + }, "PVForecastPVNodeCommonSettings": { "properties": { "api_key": { @@ -10889,7 +10995,7 @@ ], "title": "Mountingplace", "description": "Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated.", - "default": "free" + "default": "building" }, "loss": { "anyOf": [ @@ -10969,6 +11075,7 @@ ], "title": "Albedo", "description": "Proportion of the light hitting the ground that it reflects back.", + "default": 0.2, "examples": [ null ] @@ -11455,7 +11562,7 @@ "ems": { "anyOf": [ { - "$ref": "#/components/schemas/EnergyManagementCommonSettings" + "$ref": "#/components/schemas/EnergyManagementCommonSettings-Input" }, { "type": "null" diff --git a/src/akkudoktoreos/config/config.py b/src/akkudoktoreos/config/config.py index 192dd450..f70d8b07 100644 --- a/src/akkudoktoreos/config/config.py +++ b/src/akkudoktoreos/config/config.py @@ -697,7 +697,7 @@ class ConfigEOS(SingletonMixin, SettingsEOSDefaults): SettingsEOSDefaults.__init__(self, *args, **kwargs) self._initialized = True - logger.debug(f"Config setup:\n{self}") + logger.trace(f"Config setup:\n{self}") def merge_settings(self, settings: SettingsEOS) -> None: """Merges the provided settings into the global settings for EOS, with optional overwrite. diff --git a/src/akkudoktoreos/core/dataabc.py b/src/akkudoktoreos/core/dataabc.py index 8aec06b1..144b3e8d 100644 --- a/src/akkudoktoreos/core/dataabc.py +++ b/src/akkudoktoreos/core/dataabc.py @@ -1258,9 +1258,8 @@ class DataSequence(DataABC, DatabaseRecordProtocolMixin[DataRecord]): - 15-minute interval → buckets on :00, :15, :30, :45 - 1-hour interval → buckets on the hour - When False (default), the origin is ``query_start`` (or ``"start_day"`` when - no start is given), preserving the existing behaviour where buckets are - aligned to the query window rather than the clock. + When False (default), the origin is the requested start_datetime, or the timestamp + of the first returned sample if no start time was specified. Set to True when storing compacted records back to the database so that the resulting timestamps are predictable and human-readable. Leave False for @@ -1323,25 +1322,33 @@ class DataSequence(DataABC, DatabaseRecordProtocolMixin[DataRecord]): key=key, start_datetime=query_start, end_datetime=query_end, dropna=dropna ) + # Determine the resampling start to be used to calculate resample origin + if start_datetime is not None: + # Use user supplied start datetime for resampling start + resample_start = start_datetime + elif not series.empty: + # Use first data sample to define the resampling start + resample_start = to_datetime(series.index[0]) + else: + # No explicit start and no data available. + resample_start = None + # Ensure we have at least one value if series.empty: - dummy_time = ( - query_start - interval if query_start is not None else to_datetime(to_maxtime=False) - ) + dummy_time = start_datetime or end_datetime or to_datetime(to_maxtime=False) series = pd.Series( [None], index=pd.DatetimeIndex([dummy_time], tz="UTC"), name=key, ) + # prepend context samples if query_start is not None: idx = series.index - # Number of samples before query_start start_index = idx.searchsorted(pd.Timestamp(query_start), side="left") if start_index == 0: - # No value before query_start -> prepend dummy prepend = pd.Series( [series.iloc[0]], index=pd.DatetimeIndex([query_start - interval], tz="UTC"), @@ -1350,30 +1357,9 @@ class DataSequence(DataABC, DatabaseRecordProtocolMixin[DataRecord]): series = pd.concat([prepend, series]) elif start_index > 1: - # Keep only the last sample before query_start series = series.iloc[start_index - 1 :] - # Determine resample origin - if align_to_interval: - # Snap to nearest UTC epoch-aligned floor of the interval so that bucket - # timestamps land on wall-clock-round boundaries (:00, :15, :30, :45 etc.) - # regardless of sub-second jitter in query_start. - interval_sec = int(interval.total_seconds()) - if interval_sec > 0: - start_epoch = int(query_start.timestamp()) - floored_epoch = (start_epoch // interval_sec) * interval_sec - resample_origin: Union[str, pd.Timestamp] = pd.Timestamp( - floored_epoch, unit="s", tz="UTC" - ) - else: - resample_origin = query_start - else: - # Original behaviour: align to the query window start. - resample_origin = query_start - else: - # We do not have a query_start, align resample buckets to midnight of first day - resample_origin = "start_day" - + # append context samples if query_end is not None: if compare_datetimes(to_datetime(series.index[-1]), query_end).lt: append = pd.Series( @@ -1383,6 +1369,26 @@ class DataSequence(DataABC, DatabaseRecordProtocolMixin[DataRecord]): ) series = pd.concat([series, append]) + # Determine resampling origin + if align_to_interval and resample_start: + interval_sec = int(interval.total_seconds()) + + if interval_sec > 0: + start_epoch = int(resample_start.timestamp()) + floored_epoch = (start_epoch // interval_sec) * interval_sec + + resample_origin: Union[pd.Timestamp, str] = pd.Timestamp( + floored_epoch, unit="s", tz="UTC" + ) + else: + resample_origin = resample_start + else: + # Preserve original behaviour: buckets start at the resample start. + resample_origin = resample_start + if resample_origin is None: + # We have no resample origin - take start of day as default + resample_origin = "start_day" + # Check for numeric values numeric_series = pd.to_numeric(series, errors="coerce") # ensures float64, not object dtype is_numeric = numeric_series.dropna().notna().all() @@ -2611,7 +2617,8 @@ class DataContainer(SingletonMixin, DataABC): continue if series is None: - raise KeyError(f"No data found for key '{key}'.") + provider_ids = [provider.provider_id() for provider in self.enabled_providers] + raise KeyError(f"No data found for key '{key}' in enabled providers '{provider_ids}'.") return series @@ -2804,7 +2811,6 @@ class DataContainer(SingletonMixin, DataABC): if end_datetime: end_datetime = end_datetime.add(seconds=1) - # Create a DatetimeIndex based on start, end, and interval if start_datetime is None or end_datetime is None: raise ValueError( f"Can not determine datetime range. Got '{start_datetime}'..'{end_datetime}'." @@ -2832,8 +2838,13 @@ class DataContainer(SingletonMixin, DataABC): ) if reference_index is None: - reference_index = series.index + reference_index = series.index.copy() elif not series.index.equals(reference_index): + logger.error( + f"keys_to_dataframe: Time index mismatch for key '{key}'.\n" + f"ref: {reference_index},\n" + f"index: {series.index}" + ) raise ValueError(f"Time index mismatch for key '{key}'.") data[key] = series diff --git a/src/akkudoktoreos/core/ems.py b/src/akkudoktoreos/core/ems.py index 0cc1017f..651a6ec0 100644 --- a/src/akkudoktoreos/core/ems.py +++ b/src/akkudoktoreos/core/ems.py @@ -27,7 +27,10 @@ from akkudoktoreos.optimization.genetic.geneticparams import ( GeneticOptimizationParameters, ) from akkudoktoreos.optimization.genetic.geneticsolution import GeneticSolution -from akkudoktoreos.optimization.optimization import OptimizationSolution +from akkudoktoreos.optimization.optimization import ( + OptimizationAlgorithm, + OptimizationSolution, +) from akkudoktoreos.utils.datetimeutil import DateTime, to_datetime # The executor to execute the CPU heavy energy management run @@ -168,7 +171,7 @@ class EnergyManagement( self, start_datetime: Optional[DateTime] = None, mode: Optional[EnergyManagementMode] = None, - algorithm: Optional[str] = None, + algorithm: Optional[OptimizationAlgorithm] = None, genetic_parameters: Optional[GeneticOptimizationParameters] = None, genetic_generations: Optional[int] = None, genetic_seed: Optional[int] = None, @@ -192,7 +195,7 @@ class EnergyManagement( - "DISABLED": Does not run. Defaults to the mode defined in the current configuration. - algorithm (str, optional): + algorithm (OptimizationAlgorithm, optional): The algorithm to use. Must be one of: - "GENETIC": Optimization uses the `GENETIC` optimization algorithm. - "GENETIC0": Optimization uses the `GENETIC0` optimization algorithm. @@ -276,7 +279,7 @@ class EnergyManagement( algorithm = self.config.optimization.algorithm # --- GENETIC algorithm --- - if algorithm == "GENETIC": + if algorithm == OptimizationAlgorithm.GENETIC: # Prepare optimization parameters # This also creates default configurations for missing values and updates the predictions logger.info(f"{algorithm}: Starting optimzation parameter preparation.") @@ -342,7 +345,7 @@ class EnergyManagement( ) # --- GENETIC0 algorithm --- - elif algorithm == "GENETIC0": + elif algorithm == OptimizationAlgorithm.GENETIC0: # Prepare optimization parameters # This also creates default configurations for missing values and updates the predictions logger.info(f"{algorithm}: Starting optimzation parameter preparation.") diff --git a/src/akkudoktoreos/core/emsettings.py b/src/akkudoktoreos/core/emsettings.py index 80b76632..93dcb846 100644 --- a/src/akkudoktoreos/core/emsettings.py +++ b/src/akkudoktoreos/core/emsettings.py @@ -5,7 +5,7 @@ Kept in an extra module to avoid cyclic dependencies on package import. from enum import StrEnum -from pydantic import Field +from pydantic import Field, computed_field from akkudoktoreos.config.configabc import SettingsBaseModel, is_home_assistant_addon @@ -51,7 +51,17 @@ class EnergyManagementCommonSettings(SettingsBaseModel): mode: EnergyManagementMode = Field( default_factory=ems_default_mode, json_schema_extra={ - "description": "Energy management mode [DISABLED | OPTIMIZATION | PREDICTION].", - "examples": ["OPTIMIZATION", "PREDICTION"], + "description": ( + f"Energy management mode " + f"[{' | '.join(mode.value for mode in EnergyManagementMode)}]. " + f"Defaults to {ems_default_mode()}." + ), + "examples": ["OPTIMIZATION"], }, ) + + @computed_field # type: ignore[prop-decorator] + @property + def modes(self) -> list[str]: + """Available energy management modes.""" + return [mode.value for mode in EnergyManagementMode] diff --git a/src/akkudoktoreos/data/cec_inverters.csv b/src/akkudoktoreos/data/cec_inverters.csv new file mode 100644 index 00000000..ff0da6ac --- /dev/null +++ b/src/akkudoktoreos/data/cec_inverters.csv @@ -0,0 +1,2346 @@ +Name,Vac,Pso,Paco,Pdco,Vdco,C0,C1,C2,C3,Pnt,Vdcmax,Idcmax,Mppt_low,Mppt_high,CEC_Date,CEC_hybrid +Units,V,W,W,W,V,1/W,1/V,1/V,1/V,W,V,A,V,V,, +[0],inv_snl_ac_voltage,inv_snl_pso,inv_snl_paco,inv_snl_pdco,inv_snl_vdco,inv_snl_c0,inv_snl_c1,inv_snl_c2,inv_snl_c3,inv_snl_pnt,inv_snl_vdcmax,inv_snl_idcmax,inv_snl_mppt_low,inv_snl_mppt_hi,inv_cec_date,inv_cec_hybrid +ABB: PVI-30-OUTD-S-US-A {208V},208,18.1674,3000,3142.3,310,-8.03947e-06,-1.10257e-05,0.000998581,-0.000287238,0.1,480.0,10.1365,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-A {240V},240,16.8813,3000,3121.67,340,-5.7019e-06,-2.119e-05,0.000583014,-0.000712316,0.1,480.0,9.18138,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-A {277V},277,22.0466,3000,3106.85,390,-5.46446e-06,-3.3181e-05,-3.20526e-05,-0.00118014,0.2,480.0,7.96628,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-Z-A {208V},208,18.1674,3000,3142.3,310,-8.03947e-06,-1.10257e-05,0.000998581,-0.000287238,0.1,480.0,10.1365,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-Z-A {240V},240,16.8813,3000,3121.67,340,-5.7019e-06,-2.119e-05,0.000583014,-0.000712316,0.1,480.0,9.18138,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-Z-A {277V},277,22.0466,3000,3106.85,390,-5.46446e-06,-3.3181e-05,-3.20526e-05,-0.00118014,0.2,480.0,7.96628,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-Z-M-A {208V},208,18.1674,3000,3142.3,310,-8.03947e-06,-1.10257e-05,0.000998581,-0.000287238,0.1,480.0,10.1365,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-Z-M-A {240V},240,16.8813,3000,3121.67,340,-5.7019e-06,-2.119e-05,0.000583014,-0.000712316,0.1,480.0,9.18138,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-30-OUTD-S-US-Z-M-A {277V},277,22.0466,3000,3106.85,390,-5.46446e-06,-3.3181e-05,-3.20526e-05,-0.00118014,0.2,480.0,7.96628,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-A {208V},208,25.5942,3600,3757.45,310,-5.2131e-06,-3.33722e-06,0.000858902,0.000536007,0.1,480.0,12.1208,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-A {240V},240,22.8129,3600,3739.76,340,-3.04833e-06,-1.83734e-05,0.000482712,0.00102343,0.2,480.0,10.9993,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-A {277V},277,29.8083,3600,3724.19,395,-3.75283e-06,-3.53229e-05,-0.000141702,0.000468487,0.2,480.0,9.42832,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-Z-A {208V},208,25.5942,3600,3757.45,310,-5.2131e-06,-3.33722e-06,0.000858902,0.000536007,0.1,480.0,12.1208,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-Z-A {240V},240,22.8129,3600,3739.76,340,-3.04833e-06,-1.83734e-05,0.000482712,0.00102343,0.2,480.0,10.9993,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-Z-A {277V},277,29.8083,3600,3724.19,395,-3.75283e-06,-3.53229e-05,-0.000141702,0.000468487,0.2,480.0,9.42832,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-Z-M-A {208V},208,25.5942,3600,3757.45,310,-5.2131e-06,-3.33722e-06,0.000858902,0.000536007,0.1,480.0,12.1208,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-Z-M-A {240V},240,22.8129,3600,3739.76,340,-3.04833e-06,-1.83734e-05,0.000482712,0.00102343,0.2,480.0,10.9993,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-36-OUTD-S-US-Z-M-A {277V},277,29.8083,3600,3724.19,395,-3.75283e-06,-3.53229e-05,-0.000141702,0.000468487,0.2,480.0,9.42832,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-A {208V},208,25.7854,3800,3972.82,310,-4.86719e-06,-1.22618e-05,0.00104707,0.000260384,0.12,480.0,12.8156,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-A {240V},240,26.9816,3800,3950.15,340,-3.28787e-06,-2.41868e-05,0.000674436,0.000509655,0.16,480.0,11.6181,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-A {277V},277,29.741,3800,3931.93,395,-2.82258e-06,-3.82119e-05,1.82841e-05,-2.19325e-05,0.22,480.0,9.95425,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-Z-A {208V},208,25.7854,3800,3972.82,310,-4.86719e-06,-1.22618e-05,0.00104707,0.000260384,0.12,480.0,12.8156,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-Z-A {240V},240,26.9816,3800,3950.15,340,-3.28787e-06,-2.41868e-05,0.000674436,0.000509655,0.16,480.0,11.6181,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-Z-A {277V},277,29.741,3800,3931.93,395,-2.82258e-06,-3.82119e-05,1.82841e-05,-2.19325e-05,0.22,480.0,9.95425,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-Z-M-A {208V},208,25.7854,3800,3972.82,310,-4.86719e-06,-1.22618e-05,0.00104707,0.000260384,0.12,480.0,12.8156,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-Z-M-A {240V},240,26.9816,3800,3950.15,340,-3.28787e-06,-2.41868e-05,0.000674436,0.000509655,0.16,480.0,11.6181,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-38-OUTD-S-US-Z-M-A {277V},277,29.741,3800,3931.93,395,-2.82258e-06,-3.82119e-05,1.82841e-05,-2.19325e-05,0.22,480.0,9.95425,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-A {208V},208,24.6477,4200,4393.08,310,-4.83327e-06,-2.92472e-06,0.000630428,0.000205787,0.1,480.0,14.1712,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-A {240V},240,27.7352,4200,4369.96,340,-4.05955e-06,-2.39706e-05,-6.32494e-05,-0.000597557,0.2,480.0,12.8528,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-A {277V},277,29.0718,4200,4347.12,395,-3.3483e-06,-3.3851e-05,-0.000283269,0.000288563,0.2,480.0,11.0054,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-Z-A {208V},208,24.6477,4200,4393.08,310,-4.83327e-06,-2.92472e-06,0.000630428,0.000205787,0.1,480.0,14.1712,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-Z-A {240V},240,27.7352,4200,4369.96,340,-4.05955e-06,-2.39706e-05,-6.32494e-05,-0.000597557,0.2,480.0,12.8528,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-Z-A {277V},277,29.0718,4200,4347.12,395,-3.3483e-06,-3.3851e-05,-0.000283269,0.000288563,0.2,480.0,11.0054,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-Z-M-A {208V},208,24.6477,4200,4393.08,310,-4.83327e-06,-2.92472e-06,0.000630428,0.000205787,0.1,480.0,14.1712,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-Z-M-A {240V},240,27.7352,4200,4369.96,340,-4.05955e-06,-2.39706e-05,-6.32494e-05,-0.000597557,0.2,480.0,12.8528,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-42-OUTD-S-US-Z-M-A {277V},277,29.0718,4200,4347.12,395,-3.3483e-06,-3.3851e-05,-0.000283269,0.000288563,0.2,480.0,11.0054,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-A {208V},208,30.8606,5000,5208.4,310,-3.84085e-06,-3.23587e-06,0.00112996,-0.00032702,0.18,480.0,16.8013,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-A {240V},240,32.0325,5000,5190.29,345,-3.54807e-06,-1.04595e-05,0.000444815,-0.000412056,0.24,480.0,15.0443,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-A {277V},277,38.2066,5000,5162.44,400,-2.69814e-06,-1.82141e-05,0.000152786,-0.000796994,0.32,480.0,12.9061,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-Z-A {208V},208,30.8606,5000,5208.4,310,-3.84085e-06,-3.23587e-06,0.00112996,-0.00032702,0.18,480.0,16.8013,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-Z-A {240V},240,32.0325,5000,5190.29,345,-3.54807e-06,-1.04595e-05,0.000444815,-0.000412056,0.24,480.0,15.0443,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-Z-A {277V},277,38.2066,5000,5162.44,400,-2.69814e-06,-1.82141e-05,0.000152786,-0.000796994,0.32,480.0,12.9061,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-Z-M-A {208V},208,30.8606,5000,5208.4,310,-3.84085e-06,-3.23587e-06,0.00112996,-0.00032702,0.18,480.0,16.8013,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-Z-M-A {240V},240,32.0325,5000,5190.29,345,-3.54807e-06,-1.04595e-05,0.000444815,-0.000412056,0.24,480.0,15.0443,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-5000-OUTD-US-Z-M-A {277V},277,38.2066,5000,5162.44,400,-2.69814e-06,-1.82141e-05,0.000152786,-0.000796994,0.32,480.0,12.9061,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-A {208V},208,30.1749,6000,6267.34,310,-3.6046e-06,-6.05354e-06,0.00107504,-0.000452873,0.18,480.0,20.2172,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-A {240V},240,29.6929,6000,6236.59,345,-2.90334e-06,-1.30336e-05,0.000347164,-0.000752911,0.24,480.0,18.0771,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-A {277V},277,35.3609,6000,6196.81,400,-2.02936e-06,-2.40147e-05,-4.42066e-05,-0.00174888,0.32,480.0,15.492,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-Z-A {208V},208,30.1749,6000,6267.34,310,-3.6046e-06,-6.05354e-06,0.00107504,-0.000452873,0.18,480.0,20.2172,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-Z-A {240V},240,29.6929,6000,6236.59,345,-2.90334e-06,-1.30336e-05,0.000347164,-0.000752911,0.24,480.0,18.0771,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-Z-A {277V},277,35.3609,6000,6196.81,400,-2.02936e-06,-2.40147e-05,-4.42066e-05,-0.00174888,0.32,480.0,15.492,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-Z-M-A {208V},208,30.1749,6000,6267.34,310,-3.6046e-06,-6.05354e-06,0.00107504,-0.000452873,0.18,480.0,20.2172,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-Z-M-A {240V},240,29.6929,6000,6236.59,345,-2.90334e-06,-1.30336e-05,0.000347164,-0.000752911,0.24,480.0,18.0771,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVI-6000-OUTD-US-Z-M-A {277V},277,35.3609,6000,6196.81,400,-2.02936e-06,-2.40147e-05,-4.42066e-05,-0.00174888,0.32,480.0,15.492,100.0,480.0,2018-10-15 00:00:00,N +ABB: PVS-166-TL-POWER-MODULE-1-US {800V},800,493.896,165954,168888,1100,-5.15343e-08,-3.74446e-06,0.000675083,-0.000696019,12.0,1200.0,153.534,850.0,1200.0,2020-09-01 00:00:00,N +ABB: PVS-166-TL-POWER-MODULE-2-US {800V},800,493.896,165954,168888,1100,-5.15343e-08,-3.74446e-06,0.000675083,-0.000696019,12.0,1200.0,153.534,850.0,1200.0,2020-09-01 00:00:00,N +ABB: PVS-175-TL-POWER-MODULE-1-US {800V},800,713.87,179574,184379,1100,-8.64745e-08,-5.03088e-06,0.000232135,-0.000759585,12.0,1200.0,167.617,850.0,1200.0,2020-09-01 00:00:00,N +ABB: PVS-175-TL-POWER-MODULE-2-US {800V},800,713.87,179574,184379,1100,-8.64745e-08,-5.03088e-06,0.000232135,-0.000759585,12.0,1200.0,167.617,850.0,1200.0,2020-09-01 00:00:00,N +ABB: PVS-60-TL-R-US {480V},480,148.792,60033,61147.2,720,-1.41816e-07,-3.03226e-05,0.0010953,-0.000176618,0.9,800.0,84.9267,570.0,800.0,NaN,N +ABB: PVS-60-TL-S-R-US {480V},480,148.792,60033,61147.2,720,-1.41816e-07,-3.03226e-05,0.0010953,-0.000176618,0.9,800.0,84.9267,570.0,800.0,NaN,N +ABB: PVS-60-TL-S-US {480V},480,148.792,60033,61147.2,720,-1.41816e-07,-3.03226e-05,0.0010953,-0.000176618,0.9,800.0,84.9267,570.0,800.0,2020-09-01 00:00:00,N +ABB: PVS-60-TL-SC-R-US {480V},480,148.792,60033,61147.2,720,-1.41816e-07,-3.03226e-05,0.0010953,-0.000176618,0.9,800.0,84.9267,570.0,800.0,NaN,N +ABB: PVS-60-TL-SC-US {480V},480,148.792,60033,61147.2,720,-1.41816e-07,-3.03226e-05,0.0010953,-0.000176618,0.9,800.0,84.9267,570.0,800.0,2020-09-01 00:00:00,N +ABB: PVS-60-TL-US {480V},480,148.792,60033,61147.2,720,-1.41816e-07,-3.03226e-05,0.0010953,-0.000176618,0.9,800.0,84.9267,570.0,800.0,2020-09-01 00:00:00,N +ABB: TRIO-500-TL-OUTD-US-480 {480V},480,143.158,50000,50880.3,720,-1.27367e-07,-2.38736e-05,0.000979782,-0.000479972,1.0,800.0,70.6671,520.0,800.0,2018-10-15 00:00:00,N +ABB: TRIO-600-TL-OUTD-US-480 {480V},480,144.202,60000,61110.6,720,-1.222e-07,-2.0223e-05,0.000760595,-0.000952974,0.8,800.0,84.8758,570.0,800.0,2018-10-15 00:00:00,N +ABB: TRIO-TM-600-US-480 {480V},480,138.366,60000,61112.1,720,-1.40121e-07,-3.39597e-05,0.000536588,-0.00129626,0.6,800.0,84.878,570.0,800.0,2018-10-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-A {208V},208,31.9126,7600,7867.57,340,-2.13764e-06,-2.22992e-05,0.000900829,0.000352642,1.3,480.0,23.1399,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-A {240V},240,35.9449,7600,7830.65,380,-1.87222e-06,-3.72094e-05,-0.000293145,-0.000417726,1.4,480.0,20.607,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-A {277V},277,41.1381,7600,7815.42,380,-1.54362e-06,-4.79895e-05,-0.0014903,-0.00245743,1.5,480.0,20.5669,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-Z-A {208V},208,31.9126,7600,7867.57,340,-2.13764e-06,-2.22992e-05,0.000900829,0.000352642,1.3,480.0,23.1399,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-Z-A {240V},240,35.9449,7600,7830.65,380,-1.87222e-06,-3.72094e-05,-0.000293145,-0.000417726,1.4,480.0,20.607,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-Z-A {277V},277,41.1381,7600,7815.42,380,-1.54362e-06,-4.79895e-05,-0.0014903,-0.00245743,1.5,480.0,20.5669,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-Z-M-A {208V},208,31.9126,7600,7867.57,340,-2.13764e-06,-2.22992e-05,0.000900829,0.000352642,1.3,480.0,23.1399,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-Z-M-A {240V},240,35.9449,7600,7830.65,380,-1.87222e-06,-3.72094e-05,-0.000293145,-0.000417726,1.4,480.0,20.607,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-76-TL-OUTD-S-US-Z-M-A {277V},277,41.1381,7600,7815.42,380,-1.54362e-06,-4.79895e-05,-0.0014903,-0.00245743,1.5,480.0,20.5669,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-86-TL-OUTD-S-US-A {240V},240,34.0874,8600,8863.23,380,-1.55163e-06,-4.14755e-05,-0.000266664,-0.000793071,1.4,480.0,23.3243,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-86-TL-OUTD-S-US-A {277V},277,40.1776,8600,8849.66,380,-1.44207e-06,-4.9185e-05,-0.0011678,-0.00158473,1.5,480.0,23.2886,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-86-TL-OUTD-S-US-Z-A {240V},240,34.0874,8600,8863.23,380,-1.55163e-06,-4.14755e-05,-0.000266664,-0.000793071,1.4,480.0,23.3243,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-86-TL-OUTD-S-US-Z-A {277V},277,40.1776,8600,8849.66,380,-1.44207e-06,-4.9185e-05,-0.0011678,-0.00158473,1.5,480.0,23.2886,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-86-TL-OUTD-S-US-Z-M-A {240V},240,34.0874,8600,8863.23,380,-1.55163e-06,-4.14755e-05,-0.000266664,-0.000793071,1.4,480.0,23.3243,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-86-TL-OUTD-S-US-Z-M-A {277V},277,40.1776,8600,8849.66,380,-1.44207e-06,-4.9185e-05,-0.0011678,-0.00158473,1.5,480.0,23.2886,200.0,480.0,2019-02-15 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SB-RA {208V},208,18.3327,3000,3131.55,340,-5.73222e-06,-2.18162e-05,0.000812584,-0.000619687,0.9,480.0,9.21045,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SB-RA {240V},240,18.9234,3300,3425.96,355,-4.52092e-06,-3.0195e-05,0.000474884,-0.0013581,0.9,480.0,9.6506,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SB-RA-Q {208V},208,18.3327,3000,3131.55,340,-5.73222e-06,-2.18162e-05,0.000812584,-0.000619687,0.9,480.0,9.21045,200.0,480.0,NaN,N +ABB: UNO-DM-33-TL-PLUS-US-SB-RA-Q {240V},240,18.9234,3300,3425.96,355,-4.52092e-06,-3.0195e-05,0.000474884,-0.0013581,0.9,480.0,9.6506,200.0,480.0,NaN,N +ABB: UNO-DM-33-TL-PLUS-US-SE-RA {208V},208,18.3327,3000,3131.55,340,-5.73222e-06,-2.18162e-05,0.000812584,-0.000619687,0.9,480.0,9.21045,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SE-RA {240V},240,18.9234,3300,3425.96,355,-4.52092e-06,-3.0195e-05,0.000474884,-0.0013581,0.9,480.0,9.6506,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SZ-RA {208V},208,18.3327,3000,3131.55,340,-5.73222e-06,-2.18162e-05,0.000812584,-0.000619687,0.9,480.0,9.21045,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SZ-RA {240V},240,18.9234,3300,3425.96,355,-4.52092e-06,-3.0195e-05,0.000474884,-0.0013581,0.9,480.0,9.6506,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SZM-RA {208V},208,18.3327,3000,3131.55,340,-5.73222e-06,-2.18162e-05,0.000812584,-0.000619687,0.9,480.0,9.21045,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-33-TL-PLUS-US-SZM-RA {240V},240,18.9234,3300,3425.96,355,-4.52092e-06,-3.0195e-05,0.000474884,-0.0013581,0.9,480.0,9.6506,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SB-RA {208V},208,22.5793,3300,3441.95,340,-5.37154e-06,-2.9332e-05,0.000969936,-0.000453342,0.9,480.0,10.1234,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SB-RA {240V},240,23.6469,3800,3942.17,355,-3.81285e-06,-2.78869e-05,0.000880144,0.000439189,1.0,480.0,11.1047,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SB-RA-Q {208V},208,22.5793,3300,3441.95,340,-5.37154e-06,-2.9332e-05,0.000969936,-0.000453342,0.9,480.0,10.1234,200.0,480.0,NaN,N +ABB: UNO-DM-38-TL-PLUS-US-SB-RA-Q {240V},240,23.6469,3800,3942.17,355,-3.81285e-06,-2.78869e-05,0.000880144,0.000439189,1.0,480.0,11.1047,200.0,480.0,NaN,N +ABB: UNO-DM-38-TL-PLUS-US-SE-RA {208V},208,22.5793,3300,3441.95,340,-5.37154e-06,-2.9332e-05,0.000969936,-0.000453342,0.9,480.0,10.1234,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SE-RA {240V},240,23.6469,3800,3942.17,355,-3.81285e-06,-2.78869e-05,0.000880144,0.000439189,1.0,480.0,11.1047,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SZ-RA {208V},208,22.5793,3300,3441.95,340,-5.37154e-06,-2.9332e-05,0.000969936,-0.000453342,0.9,480.0,10.1234,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SZ-RA {240V},240,23.6469,3800,3942.17,355,-3.81285e-06,-2.78869e-05,0.000880144,0.000439189,1.0,480.0,11.1047,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SZM-RA {208V},208,22.5793,3300,3441.95,340,-5.37154e-06,-2.9332e-05,0.000969936,-0.000453342,0.9,480.0,10.1234,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-38-TL-PLUS-US-SZM-RA {240V},240,23.6469,3800,3942.17,355,-3.81285e-06,-2.78869e-05,0.000880144,0.000439189,1.0,480.0,11.1047,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SB-RA {208V},208,20.8986,4200,4392.77,340,-4.4854e-06,-3.07071e-05,0.00105434,-0.000137371,0.9,480.0,12.9199,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SB-RA {240V},240,24.3548,4600,4783.44,355,-3.93666e-06,-3.14168e-05,0.000757538,-0.000288942,1.0,480.0,13.4745,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SB-RA-Q {208V},208,20.8986,4200,4392.77,340,-4.4854e-06,-3.07071e-05,0.00105434,-0.000137371,0.9,480.0,12.9199,200.0,480.0,NaN,N +ABB: UNO-DM-46-TL-PLUS-US-SB-RA-Q {240V},240,24.3548,4600,4783.44,355,-3.93666e-06,-3.14168e-05,0.000757538,-0.000288942,1.0,480.0,13.4745,200.0,480.0,NaN,N +ABB: UNO-DM-46-TL-PLUS-US-SE-RA {208V},208,20.8986,4200,4392.77,340,-4.4854e-06,-3.07071e-05,0.00105434,-0.000137371,0.9,480.0,12.9199,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SE-RA {240V},240,24.3548,4600,4783.44,355,-3.93666e-06,-3.14168e-05,0.000757538,-0.000288942,1.0,480.0,13.4745,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SZ-RA {208V},208,20.8986,4200,4392.77,340,-4.4854e-06,-3.07071e-05,0.00105434,-0.000137371,0.9,480.0,12.9199,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SZ-RA {240V},240,24.3548,4600,4783.44,355,-3.93666e-06,-3.14168e-05,0.000757538,-0.000288942,1.0,480.0,13.4745,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SZM-RA {208V},208,20.8986,4200,4392.77,340,-4.4854e-06,-3.07071e-05,0.00105434,-0.000137371,0.9,480.0,12.9199,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-46-TL-PLUS-US-SZM-RA {240V},240,24.3548,4600,4783.44,355,-3.93666e-06,-3.14168e-05,0.000757538,-0.000288942,1.0,480.0,13.4745,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SB-RA {208V},208,27.7352,4600,4776.1,340,-3.37868e-06,-6.15998e-06,0.00207915,0.00043908,1.0,480.0,14.0474,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SB-RA {240V},240,30.7995,5000,5173.04,355,-3.03894e-06,-2.64776e-05,0.00125607,-0.000294682,1.0,480.0,14.5719,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SB-RA-QU {208V},208,27.7352,4600,4776.1,340,-3.37868e-06,-6.15998e-06,0.00207915,0.00043908,1.0,480.0,14.0474,240.0,480.0,NaN,N +ABB: UNO-DM-50-TL-PLUS-US-SB-RA-QU {240V},240,30.7995,5000,5173.04,355,-3.03894e-06,-2.64776e-05,0.00125607,-0.000294682,1.0,480.0,14.5719,200.0,480.0,NaN,N +ABB: UNO-DM-50-TL-PLUS-US-SE-RA {208V},208,27.7352,4600,4776.1,340,-3.37868e-06,-6.15998e-06,0.00207915,0.00043908,1.0,480.0,14.0474,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SE-RA {240V},240,30.7995,5000,5173.04,355,-3.03894e-06,-2.64776e-05,0.00125607,-0.000294682,1.0,480.0,14.5719,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SZ-RA {208V},208,27.7352,4600,4776.1,340,-3.37868e-06,-6.15998e-06,0.00207915,0.00043908,1.0,480.0,14.0474,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SZ-RA {240V},240,30.7995,5000,5173.04,355,-3.03894e-06,-2.64776e-05,0.00125607,-0.000294682,1.0,480.0,14.5719,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SZ-RA-U {208V},208,27.7352,4600,4776.1,340,-3.37868e-06,-6.15998e-06,0.00207915,0.00043908,1.0,480.0,14.0474,240.0,480.0,NaN,N +ABB: UNO-DM-50-TL-PLUS-US-SZ-RA-U {240V},240,30.7995,5000,5173.04,355,-3.03894e-06,-2.64776e-05,0.00125607,-0.000294682,1.0,480.0,14.5719,200.0,480.0,NaN,N +ABB: UNO-DM-50-TL-PLUS-US-SZM-RA {208V},208,27.7352,4600,4776.1,340,-3.37868e-06,-6.15998e-06,0.00207915,0.00043908,1.0,480.0,14.0474,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-50-TL-PLUS-US-SZM-RA {240V},240,30.7995,5000,5173.04,355,-3.03894e-06,-2.64776e-05,0.00125607,-0.000294682,1.0,480.0,14.5719,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-S-XRA {208V},208,26.0106,6000,6212.88,340,-2.74483e-06,-2.14278e-05,0.00150977,-0.000167176,1.3,480.0,18.2732,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-S-XRA {240V},240,26.377,6000,6183.46,355,-2.12086e-06,-3.7327e-05,0.000644202,-0.00155834,1.3,480.0,17.4182,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SB-RA {208V},208,26.0106,6000,6212.88,340,-2.74483e-06,-2.14278e-05,0.00150977,-0.000167176,1.3,480.0,18.2732,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SB-RA {240V},240,26.377,6000,6183.46,355,-2.12086e-06,-3.7327e-05,0.000644202,-0.00155834,1.3,480.0,17.4182,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SB-RA-QU {208V},208,26.0106,6000,6212.88,340,-2.74483e-06,-2.14278e-05,0.00150977,-0.000167176,1.3,480.0,18.2732,240.0,480.0,NaN,N +ABB: UNO-DM-60-TL-PLUS-US-SB-RA-QU {240V},240,26.377,6000,6183.46,355,-2.12086e-06,-3.7327e-05,0.000644202,-0.00155834,1.3,480.0,17.4182,200.0,480.0,NaN,N +ABB: UNO-DM-60-TL-PLUS-US-SC-RA {208V},208,26.0106,6000,6212.88,340,-2.74483e-06,-2.14278e-05,0.00150977,-0.000167176,1.3,480.0,18.2732,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SC-RA {240V},240,26.377,6000,6183.46,355,-2.12086e-06,-3.7327e-05,0.000644202,-0.00155834,1.3,480.0,17.4182,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SE-RA {208V},208,26.0106,6000,6212.88,340,-2.74483e-06,-2.14278e-05,0.00150977,-0.000167176,1.3,480.0,18.2732,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SE-RA {240V},240,26.377,6000,6183.46,355,-2.12086e-06,-3.7327e-05,0.000644202,-0.00155834,1.3,480.0,17.4182,200.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SZM-RA {208V},208,26.0106,6000,6212.88,340,-2.74483e-06,-2.14278e-05,0.00150977,-0.000167176,1.3,480.0,18.2732,240.0,480.0,2020-08-21 00:00:00,N +ABB: UNO-DM-60-TL-PLUS-US-SZM-RA {240V},240,26.377,6000,6183.46,355,-2.12086e-06,-3.7327e-05,0.000644202,-0.00155834,1.3,480.0,17.4182,200.0,480.0,2020-08-21 00:00:00,N +AIMS Power Inc: PIHY4600 {240V},240,32.2083,4600.42,4704.43,360,1.83058e-06,-4.7989e-06,-0.00065533,-0.00159696,0.55,480.0,13.0679,170.0,480.0,NaN,Y +AIMS Power Inc: PIHY9600 {240V},240,68.2534,9592,9801.18,360,9.27084e-07,1.78258e-06,4.04808e-05,-0.00617076,0.65,480.0,27.2255,235.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF46K-DH {240V},240,32.2083,4600,4704.01,360,1.83058e-06,-4.80053e-06,-0.00065533,-0.00159696,0.55,480.0,13.0667,170.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V},240,35.032,4998,5112.69,360,1.21953e-06,-3.46378e-06,-0.000410412,-0.00708724,0.54,480.0,14.2019,185.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V},240,46.4321,5995,6142.55,360,1.27597e-06,-2.21185e-06,1.01713e-05,-0.00446573,0.55,480.0,17.0626,220.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF76K-DH {240V},240,46.8629,7599,7788.38,360,1.68907e-06,-8.54752e-06,-0.000296433,-0.00064651,0.55,480.0,21.6344,185.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V},240,58.0629,6996,7144.62,360,9.65517e-07,-4.15836e-06,0.00096827,-0.0114371,0.55,480.0,19.8462,170.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF86K-DH {240V},240,42.4619,8596,8779.3,360,1.47739e-06,-4.49071e-06,-0.00021973,-0.00166775,0.58,480.0,24.387,210.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF8K-DH {240V},240,53.9616,7999,8179.83,360,1.08605e-06,-7.06233e-06,0.000562723,-0.00382322,0.64,480.0,22.7217,195.0,480.0,NaN,Y +Afore New Energy Technology (Shanghai) Co Ltd: AF96K-DH {240V},240,68.2534,9592,9801.18,360,9.27084e-07,1.78258e-06,4.04808e-05,-0.00617076,0.65,480.0,27.2255,235.0,480.0,NaN,Y +Alpha ESS Co Ltd: SMILE-SP76-INV {240V},240,23.6229,7644,7879.19,400,-1.79962e-06,-4.55113e-05,4.58198e-05,-0.00022833,9.44,480.0,19.698,230.0,480.0,2024-09-23 00:00:00,Y +Alpha ESS Co Ltd: SMILE-SP96-INV {240V},240,22.5217,9628,9953.88,400,-1.73591e-06,-3.05626e-05,5.56075e-05,-0.000191056,9.4,480.0,24.8847,300.0,480.0,2024-09-23 00:00:00,Y +Alpha ESS Co Ltd: SMILE-SPB76-INV {240V},240,29.9914,7648,7937.29,350,-1.80177e-06,-2.43109e-05,0.00102836,-0.000548668,9.48,495.0,22.678,200.0,495.0,2024-09-23 00:00:00,N +Alpha ESS Co Ltd: SMILE-SPB96-INV {240V},240,28.4253,9616,10001.2,350,-1.65015e-06,-4.45987e-05,0.000439791,-0.00226839,9.5,450.0,28.5748,200.0,450.0,2024-09-23 00:00:00,N +Altenergy Power System Inc: DS3 {240V},240,5.60963,896,923.523,39,-1.53294e-05,0.00049265,0.0749071,0.0437757,0.0307,43.0,23.6801,36.0,43.0,2023-04-21 00:00:00,N +Altenergy Power System Inc: DS3-H {240V},240,5.43718,1068,1104.11,39,-1.76248e-05,0.000464755,0.0666435,0.0283836,0.0302,43.0,28.3104,36.0,43.0,2023-04-21 00:00:00,N +Altenergy Power System Inc: DS3-L {240V},240,5.30723,780,802.926,39,-1.45056e-05,0.000485016,0.0780655,0.0631421,0.0298,43.0,20.5878,36.0,43.0,2023-04-21 00:00:00,N +Altenergy Power System Inc: DS3-LV {120V},120,7.41107,915,972.578,36,-4.44501e-05,9.31153e-05,0.0518661,0.00682734,0.03,45.0,27.0161,28.0,45.0,NaN,N +Altenergy Power System Inc: DS3-S {240V},240,5.2526,656,674.705,39,-1.41975e-05,0.000488449,0.0920798,0.11128,0.0309,43.0,17.3001,36.0,43.0,2023-04-21 00:00:00,N +Altenergy Power System Inc: ELS-114 {208V},208,123.176,10011,10784.1,56,-4.50499e-06,-0.000446645,0.0256817,-0.0219408,10.59,60.0,192.573,51.0,60.0,2025-01-13 00:00:00,N +Altenergy Power System Inc: ELS-114 {240V},240,119.237,11415,12263.5,56,-4.10729e-06,-0.000721385,0.0301534,-0.0195134,11.03,60.0,218.991,51.0,60.0,2025-01-13 00:00:00,N +Altenergy Power System Inc: ELS-3K {240V},240,60.4512,3685,3903.4,56,-9.27688e-06,-0.000484047,0.0116877,-0.0497113,4.271,60.0,69.7035,52.0,60.0,NaN,N +Altenergy Power System Inc: ELS-5K {240V},240,71.9099,5008,5372.72,56,-1.09717e-05,-0.00103564,0.0201036,-0.029413,4.006,60.0,95.9415,52.0,60.0,NaN,N +Altenergy Power System Inc: ELS-76 {208V},208,118.321,6606,7030.87,56,-4.24642e-06,0.000155773,0.0290983,-0.0168454,10.55,60.0,125.551,51.0,60.0,2025-01-13 00:00:00,N +Altenergy Power System Inc: ELS-76 {240V},240,116.89,7609,8067.93,56,-3.70412e-06,-0.00013064,0.0292371,-0.0247105,11.06,60.0,144.07,51.0,60.0,2025-01-13 00:00:00,N +Altenergy Power System Inc: ELS-96 {208V},208,122.618,8308,8885.99,56,-4.38816e-06,-0.000145843,0.0272187,-0.0209251,10.55,60.0,158.678,51.0,60.0,2025-01-13 00:00:00,N +Altenergy Power System Inc: ELS-96 {240V},240,118.148,9606,10245.6,56,-3.87507e-06,-0.000440606,0.0288108,-0.0247616,11.04,60.0,182.956,51.0,60.0,2025-01-13 00:00:00,N +Altenergy Power System Inc: EZ1-LV {120V},120,7.41107,915,972.578,36,-4.44501e-05,9.31153e-05,0.0518661,0.00682734,0.03,45.0,27.0161,28.0,45.0,NaN,N +Altenergy Power System Inc: QS1 {208V},208,4.06728,1218.3,1271.46,37.5,-1.71481e-05,-0.000252683,0.00477785,-0.0224433,0.046,48.0,33.9057,27.0,48.0,NaN,N +Altenergy Power System Inc: QS1 {240V},240,6.89574,1225,1275.78,37.5,-1.85437e-05,-0.000323582,0.00498988,-0.0146046,0.09,48.0,34.0207,27.0,48.0,2020-04-21 00:00:00,N +Altenergy Power System Inc: QS1200 {240V},240,6.89574,1225,1275.78,37.5,-1.85437e-05,-0.000323582,0.00498988,-0.0146046,0.09,48.0,34.0207,27.0,48.0,2020-04-21 00:00:00,N +Altenergy Power System Inc: QS1A {240V},240,5.32036,1516,1583.31,41,-1.51065e-05,-0.000282304,0.000659336,-0.0258672,0.038,52.0,38.6174,30.0,52.0,NaN,N +Altenergy Power System Inc: QS2 {208V},208,16.9316,1922.64,2029.64,38,-1.8309e-05,0.00019808,0.0321214,0.00132731,0.003,45.0,53.4116,30.0,45.0,NaN,N +Altenergy Power System Inc: QS2 {240V},240,18.1577,1923.89,2020.5,38,-1.71659e-05,0.000191767,0.029581,-0.000539802,0.004,45.0,53.1711,30.0,45.0,NaN,N +Altenergy Power System Inc: QT2 {208V},208,16.0257,1733,1813.38,38,-1.75149e-05,0.000246838,0.01273,-0.00788986,0.087,42.0,47.7204,34.0,42.0,2023-05-11 00:00:00,N +Altenergy Power System Inc: QT2 {480V},480,9.2364,1821,1896.44,38,6.83257e-07,0.00123179,-0.010247,0.54952,0.2248,42.0,49.9063,34.0,42.0,2023-05-11 00:00:00,N +Altenergy Power System Inc: QT2-208 {208V},208,16.0257,1733,1813.38,38,-1.75149e-05,0.000246838,0.01273,-0.00788986,0.087,42.0,47.7204,34.0,42.0,2023-05-11 00:00:00,N +Altenergy Power System Inc: QT2-480 {480V},480,9.2364,1821,1896.44,38,6.83257e-07,0.00123179,-0.010247,0.54952,0.2248,42.0,49.9063,34.0,42.0,2023-05-11 00:00:00,N +Altenergy Power System Inc: YC600 {240V},240,1.99045,550,569.902,36,-1.02282e-05,-0.000312211,0.0059075,-0.0811195,0.02,45.0,15.8306,24.0,45.0,2020-04-13 00:00:00,N +Amensolar Ess Co Ltd: N3H-X100-US {240V},240,51.9471,10177,10475.8,360,-1.26046e-06,-2.00269e-05,-4.72702e-05,-0.000721728,33.64,430.0,29.0994,280.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X10US {240V},240,51.9686,10177,10475.7,360,-1.26033e-06,-2.0449e-05,-5.21533e-05,-0.000766056,33.64,430.0,29.0991,280.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X12US {240V},240,51.9675,12214,12699.8,360,-1.35886e-06,-3.77971e-05,0.00236429,0.00361106,13.202,430.0,35.2773,200.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X16US {240V},240,67.3944,16199,16830.4,360,-9.00267e-07,-1.12249e-05,0.00529221,0.00962936,16.199,430.0,46.7511,220.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X50-US {240V},240,29.3587,5090,5247.89,360,-3.6512e-06,-1.51195e-05,0.000125821,0.000551915,22.6,430.0,14.5775,180.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X5US {240V},240,29.4226,5090,5247.94,360,-3.6715e-06,-1.52557e-05,0.000115341,0.000536988,22.6,430.0,14.5776,180.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X60-US {240V},240,33.6679,6117,6297.73,360,-2.58712e-06,-2.03092e-05,0.000191477,-0.0002564,22.99,430.0,17.4937,200.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X76-US {240V},240,37.4864,7765,7993.33,360,-1.60481e-06,-2.20802e-05,-0.000935129,-0.00139184,30.71,430.0,22.2037,220.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X80-US {240V},240,65.7917,8084,8326.87,360,-2.95092e-06,-5.90796e-06,-0.000931502,-0.00173603,17.4,430.0,23.1302,250.0,430.0,NaN,Y +Amensolar Ess Co Ltd: N3H-X8US {240V},240,65.7917,8084,8326.87,360,-2.95092e-06,-5.90796e-06,-0.000931502,-0.00173603,17.4,430.0,23.1302,250.0,430.0,NaN,Y +Anker Innovations Limited: A17E1 {240V},240,53.9373,7687,8010.6,400,-3.2575e-06,-5.57028e-05,-0.00286242,-0.000268771,8.23,450.0,20.0265,350.0,450.0,NaN,Y +Anker Innovations Limited: MI80 {240V},240,5.60963,896,923.523,39,-1.53294e-05,0.00049265,0.0749071,0.0437758,0.0307,43.0,23.6801,36.0,43.0,NaN,N +Anker Innovations Limited: MI80H {240V},240,5.43718,1068,1104.11,39,-1.76248e-05,0.000464755,0.0666435,0.0283836,0.0302,43.0,28.3104,36.0,43.0,NaN,N +Anker Innovations Limited: MI80L {240V},240,5.30723,780,802.926,39,-1.45056e-05,0.000485016,0.0780655,0.063142,0.0298,43.0,20.5878,36.0,43.0,NaN,N +Anker Innovations Limited: MI80S {240V},240,5.2526,656,674.705,39,-1.41975e-05,0.000488449,0.0920798,0.11128,0.0309,43.0,17.3001,36.0,43.0,NaN,N +Anker Innovations Limited: X1-P6K-US {240V},240,19.3696,6040,6199.12,400,-1.72104e-06,3.16953e-05,0.00214596,0.000595014,7.5,450.0,15.4978,365.0,450.0,NaN,N +Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V},120,4.24942,326,358.364,44,-0.000128156,-0.000533008,-0.00432125,-0.0183435,0.528,52.0,8.14463,36.0,52.0,NaN,N +Apparent Inc: SG424U CA 120VAC 60Hz {120V},120,3.58064,250,274.404,36.4,-0.00018406,-0.000804861,-0.0123665,-0.0326001,0.45,48.9,7.53858,31.2,48.9,2022-08-22 00:00:00,N +Aptos Solar Technology LLC: MAC-400 {208V},208,1.39087,387.262,402.933,42,-3.70145e-05,-0.000342727,-0.0303584,-0.0672045,0.09,48.0,9.59365,38.0,48.0,NaN,N +Aptos Solar Technology LLC: MAC-400 {240V},240,0.712961,382.54,396.349,42,-1.0523e-05,-0.000291685,-0.113573,-0.329599,0.105,48.0,9.43688,34.0,48.0,2023-05-01 00:00:00,N +Aptos Solar Technology LLC: MAC-400R {208V},208,1.39087,387.262,402.933,42,-3.70145e-05,-0.000342727,-0.0303584,-0.0672045,0.09,48.0,9.59365,38.0,48.0,NaN,N +Aptos Solar Technology LLC: MAC-400R {240V},240,0.712961,382.54,396.349,42,-1.0523e-05,-0.000291685,-0.113573,-0.329599,0.105,48.0,9.43688,34.0,48.0,2023-05-01 00:00:00,N +Aptos Solar Technology LLC: MAC-800 {208V},208,2.91615,767,797.921,42,-1.98717e-05,-2.64317e-05,0.00914614,-0.00141587,0.11,48.0,18.9981,34.0,48.0,NaN,N +Aptos Solar Technology LLC: MAC-800 {240V},240,1.43228,767,795.035,42,-5.42142e-06,-0.000302424,-0.0766967,-0.26529,0.11,48.0,18.9294,34.0,48.0,2023-05-01 00:00:00,N +Aptos Solar Technology LLC: MAC-800R {208V},208,2.91615,767,797.921,42,-1.98717e-05,-2.64317e-05,0.00914614,-0.00141587,0.11,48.0,18.9981,34.0,48.0,NaN,N +Aptos Solar Technology LLC: MAC-800R {240V},240,1.43228,767,795.035,42,-5.42142e-06,-0.000302424,-0.0766967,-0.26529,0.11,48.0,18.9294,34.0,48.0,2023-05-01 00:00:00,N +BYD Auto Industry Company Limited: BEG500KTL-U {480V},480,4549.66,501756,521992,890,-3.45645e-08,2.12268e-05,0.000603471,0.000463011,2.0,1000.0,586.508,780.0,1000.0,NaN,N +BYD Auto Industry Company Limited: BEG500KTL-U/01 {480V},480,4549.66,501756,521992,890,-3.45645e-08,2.12268e-05,0.000603471,0.000463011,2.0,1000.0,586.508,780.0,1000.0,NaN,N +BYD Auto Industry Company Limited: BEG60KTL-U-R1 {480V},480,434.674,60276,62994,850,-3.37224e-07,2.52411e-05,0.000657162,0.000196041,98.0,950.0,74.1106,750.0,950.0,2023-02-01 00:00:00,N +Base Power Inc: MIN 10000TL-XH-US {240V},240,39.5146,10082,10328.5,380,-1.31953e-06,-4.36227e-05,0.000405515,-0.000846426,10.0,480.0,27.1802,250.0,480.0,NaN,Y +Base Power Inc: MIN 11400TL-XH-US {240V},240,41.2688,11520,11783.5,380,-1.09624e-06,-1.63085e-05,0.00014452,-2.54053e-05,10.0,480.0,31.0093,250.0,480.0,NaN,Y +Base Power Inc: MIN 3000TL-XH-US {240V},240,16.9589,3095,3184.22,380,-3.75554e-06,-3.82152e-05,-0.000858481,-0.00160756,1.593,480.0,8.37954,125.0,480.0,NaN,Y +Base Power Inc: MIN 3800TL-XH-US {240V},240,19.9959,3888,3987.16,380,-2.96039e-06,-4.18045e-05,-0.000716973,-0.000643354,1.593,480.0,10.4925,160.0,480.0,NaN,Y +Base Power Inc: MIN 5000TL-XH-US {240V},240,21.1886,4943,5075.82,380,-3.22302e-06,-4.7108e-05,-0.000573923,-0.000712923,1.593,480.0,13.3574,210.0,480.0,NaN,Y +Base Power Inc: MIN 6000TL-XH-US {240V},240,23.0661,5918,6084.58,380,-2.3168e-06,-4.22293e-05,-0.00156567,0.000104517,1.593,480.0,16.0121,170.0,480.0,NaN,Y +Base Power Inc: MIN 7600TL-XH-US {240V},240,35.2212,7524,7741.49,380,-2.91717e-06,-3.67176e-05,-0.000401827,-0.000518179,1.593,480.0,20.3723,212.0,480.0,NaN,Y +Base Power Inc: MIN 8200TL-XH-US {240V},240,42.4825,8251,8445.17,380,-1.52261e-06,-3.89029e-05,0.000360027,-0.000552598,10.0,480.0,22.2241,250.0,480.0,NaN,Y +Base Power Inc: MIN 9000TL-XH-US {240V},240,41.617,9063,9277.47,380,-1.37093e-06,-4.1912e-05,0.00028924,-0.000637612,10.0,480.0,24.4144,250.0,480.0,NaN,Y +CE+T America Inc: 30C {480V},480,170.35,29990,31488.5,700,-1.91245e-07,-2.12687e-05,0.00183697,-0.00911886,56.8,850.0,44.9836,550.0,850.0,2022-01-03 00:00:00,Y +CE+T America Inc: 30C3 {480V},480,170.35,29990,31488.5,700,-1.91245e-07,-2.12687e-05,0.00183697,-0.00911886,56.8,850.0,44.9836,550.0,850.0,2022-01-03 00:00:00,Y +CESC New Energy Technology Co Ltd: Mars 9600 HVSP {240V},240,68.2534,9592,9801.18,360,9.27084e-07,1.78258e-06,4.04808e-05,-0.00617076,0.65,480.0,27.2255,235.0,480.0,NaN,Y +CSI Solar Co Ltd: CSEC-200K-T6901A-U {690V},690,281.348,200706,203933,1325,-4.06658e-08,1.01077e-05,0.00136663,0.000176366,11.0,1500.0,153.912,1000.0,1500.0,NaN,N +CSI Solar Co Ltd: CSEC-215K-T6901A-U {690V},690,256.815,215937,219497,1325,-3.74084e-08,9.86761e-06,0.00196298,0.000586889,11.0,1500.0,165.658,1000.0,1500.0,NaN,N +CSI Solar Co Ltd: CSI-100K-T480GL02-U {480V},480,117.287,100000,101782,720,-9.94018e-08,-2.91638e-06,0.000305908,0.00061374,1.0,850.0,141.364,550.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-100K-T480GL03-U {480V},480,83.3344,99368,101480,730,-9.89649e-08,-2.16309e-05,-0.00421283,-0.000696959,2.0,850.0,139.013,550.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-125K-T600GL02-U {600V},600,145.212,125083,127176,1080,-7.90126e-08,-2.40218e-06,0.000251427,0.000453422,1.0,1250.0,117.756,860.0,1250.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-125KTL-GS-E {600V},600,40.5821,125000,126734,950,-3.53178e-08,1.1619e-05,0.00466754,0.00303841,1.0,1250.0,133.404,860.0,1250.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-185K-T600GL02-U {600V},600,328.673,185005,188214,1080,-5.97009e-08,-4.53711e-06,0.00108483,0.000387473,1.0,1300.0,174.273,850.0,1300.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-185K-T600GL03-U {600V},600,328.673,185005,188214,1080,-5.97009e-08,-4.53711e-06,0.00108483,0.000387473,1.0,1300.0,174.273,850.0,1300.0,NaN,N +CSI Solar Co Ltd: CSI-255K-T800GL02-U {800V},800,394.759,255013,259309,1080,-3.6601e-08,-6.05916e-06,-0.000208903,-0.000323189,1.0,1300.0,240.101,850.0,1300.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-255K-T800GL03-U {800V},800,394.759,255013,259309,1080,-3.6601e-08,-6.05916e-06,-0.000208903,-0.000323189,1.0,1300.0,240.101,850.0,1300.0,NaN,N +CSI Solar Co Ltd: CSI-25K-T480GL01-UB {480V},480,28.9305,24958,25377.7,470,-2.44159e-07,-4.97673e-07,0.000519154,0.000650116,1.0,800.0,53.9951,347.0,800.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-25K-T480GL03-U {480V},480,15.3191,24887.6,25299.2,720,-1.96133e-07,-2.23478e-06,-0.00265327,-0.00269342,3.2724,850.0,35.1377,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-25KTL-GS-FLB {480V},480,68.8259,25000,25568,650,-3.72917e-07,1.67241e-05,-0.000736454,0.0012912,14.0,770.0,39.3353,580.0,770.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-30K-T208GL03-U {208V},208,84.9098,29878,31000.4,580,-7.9747e-07,3.01359e-06,0.000167207,-0.000164951,1.394,680.0,53.449,340.0,680.0,NaN,N +CSI Solar Co Ltd: CSI-30K-T480GL01-UB {480V},480,39.2007,29948,30453,700,-2.38831e-07,-1.1208e-06,0.000107757,0.000314952,1.0,800.0,43.5042,417.0,800.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-30K-T480GL03-U {480V},480,36.132,29883,30405,720,-2.67085e-07,-2.82587e-06,-0.000846519,-0.000952389,3.2724,850.0,42.2291,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-30KTL-GS-FLB {480V},480,52.9619,30000,30650.7,650,-2.97196e-07,4.62228e-06,0.00134634,0.00171057,15.0,780.0,47.155,580.0,780.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-33K-T480GL03-U {480V},480,23.6289,32865,33414.1,720,-1.84907e-07,-9.43334e-07,0.000577347,0.000401846,3.2724,850.0,46.4084,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-36K-T480GL01-UB {480V},480,55.7239,35925,36538.6,700,-2.2726e-07,-5.7441e-07,0.000333924,0.000618578,1.0,800.0,52.1979,500.0,800.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-36K-T480GL03-U {480V},480,38.3233,35866,36520.8,720,-2.71062e-07,1.95129e-06,0.000864189,0.000780439,3.2724,850.0,50.7234,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-36KTL-GS-FLB {480V},480,45.2456,36000,36692.4,650,-1.67703e-07,2.79933e-06,0.00244407,0.00328274,15.0,780.0,56.4498,580.0,780.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-40K-T480GL01-UB {480V},480,58.3804,39926,40601.4,700,-1.85632e-07,-7.73373e-07,0.000603043,0.000910515,1.0,800.0,58.0021,556.0,800.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-40K-T480GL03-U {480V},480,107.802,39841,40644.3,720,-4.54891e-07,1.07183e-05,0.000306405,0.00129958,3.2724,850.0,56.4504,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-40KTL-GS-B {480V},480,61.0596,40000,40735.5,650,-1.69944e-07,-8.69564e-06,0.000553295,-0.000145478,1.0,780.0,62.67,580.0,780.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-40KTL-GS-FLB {480V},480,61.9905,40000,40735.5,650,-1.72763e-07,-8.61697e-06,0.000412271,-0.000364738,1.0,780.0,62.67,580.0,780.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-50K-T480GL01-UB {480V},480,74.5542,49916,50766.4,720,-1.56866e-07,-5.33876e-07,0.000585649,0.000882891,1.0,850.0,70.5089,568.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-50K-T480GL03-U {480V},480,104.275,49848,50714.8,720,-2.255e-07,-6.55568e-06,0.000373405,-0.00106045,3.2724,850.0,70.4372,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-50KTL-GS-B {480V},480,68.875,50000,50815.3,650,-1.47078e-07,-8.10917e-06,0.000351798,0.00104103,1.0,720.0,78.1774,580.0,720.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-50KTL-GS-FLB {480V},480,44.5102,50000,50786.7,650,-8.79096e-08,-5.21277e-06,0.00294909,0.00814369,1.0,720.0,78.1334,580.0,720.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-60K-T480GL01-UB {480V},480,88.6769,59933,60960.5,720,-1.34947e-07,-1.57113e-06,0.000349874,0.000407741,1.0,850.0,84.6674,526.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-60K-T480GL03-U {480V},480,121.037,59898,60956.2,720,-1.91613e-07,-1.90255e-06,0.000811883,8.54779e-05,3.1623,850.0,84.6614,580.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-60KTL-GS-B {480V},480,87.0111,60000,61017.8,650,-1.31794e-07,-1.62198e-05,-0.000918025,-0.00145187,1.0,720.0,93.8735,580.0,720.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-66K-T480GL01-UB {480V},480,103.177,65926,67057.4,720,-1.2482e-07,-5.83072e-07,0.000528093,0.000772483,1.0,850.0,93.1353,579.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-66KTL-GS-B {480V},480,95.4561,66000,67082.2,650,-1.1455e-07,-1.23648e-05,-0.00104525,-0.000304874,1.0,720.0,103.203,580.0,720.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-75K-T480GL02-U {480V},480,87.1138,75000,76332.4,720,-1.31519e-07,-2.94922e-06,0.000373221,0.000626437,1.0,850.0,106.017,550.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-75K-T480GL03-U {480V},480,100.985,74574,75961.2,730,-1.00225e-07,-1.8402e-05,-0.00194831,-0.00193715,2.0,850.0,104.056,550.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-80K-T480GL02-U {480V},480,93.7255,80000,81422.3,720,-1.24267e-07,-2.95835e-06,0.000358831,0.000629308,1.0,850.0,113.086,550.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-80K-T480GL03-U {480V},480,85.2043,79446,80980.1,730,-1.06763e-07,-1.91641e-05,-0.00190658,-0.000627037,2.0,850.0,110.932,550.0,850.0,NaN,N +CSI Solar Co Ltd: CSI-90K-T480GL02-U {480V},480,105.665,90000,91602.8,720,-1.10257e-07,-2.90948e-06,0.000304185,0.000610039,1.0,850.0,127.226,550.0,850.0,2021-12-01 00:00:00,N +CSI Solar Co Ltd: CSI-90K-T480GL03-U {480V},480,83.3011,89449,91284.7,730,-1.1002e-07,-2.01152e-05,-0.00246781,-0.000565624,2.0,850.0,125.048,550.0,850.0,NaN,N +Canadian Solar Inc: CSI-25KTL-GS-FL {480V},480,65.3352,25000,25581.9,650,-3.96177e-07,1.35059e-05,0.000622038,0.00289364,14.0,780.0,39.3568,580.0,780.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-30KTL-GS-FL {480V},480,41.2876,30000,30664.3,650,-2.61207e-07,1.27313e-06,0.00598325,0.00541474,15.0,780.0,47.1759,580.0,780.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-36KTL-CT {480V},480,80.1024,36000,36701.7,730,-2.33292e-07,-3.88036e-05,-0.0027293,-0.00119439,10.8,800.0,50.2763,540.0,800.0,2018-11-01 00:00:00,N +Canadian Solar Inc: CSI-36KTL-GS-FL {480V},480,26.7656,36000,36714.2,650,-1.19224e-07,-4.75344e-06,0.00951705,0.00624775,15.0,780.0,56.4834,580.0,780.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-40KTL-GS {480V},480,78.3542,40000,40816.9,650,-2.85188e-07,-1.02547e-05,-3.04299e-05,-0.000796888,1.0,780.0,62.7952,580.0,780.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-40KTL-GS-FL {480V},480,62.922,40000,40750.1,650,-1.90174e-07,-7.79676e-06,-0.000160631,-0.00072261,1.0,780.0,62.6925,580.0,780.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-50KTL-CT {480V},480,95.1272,50000,50835.1,730,-1.438e-07,-2.37286e-05,-0.0036747,-0.00124718,0.88,850.0,69.6372,480.0,850.0,2018-11-01 00:00:00,N +Canadian Solar Inc: CSI-50KTL-GS {480V},480,70.4536,50000,50800.1,650,-1.45825e-07,-6.68995e-06,-7.73075e-05,0.00139143,1.0,720.0,78.1541,580.0,720.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-50KTL-GS-FL {480V},480,42.454,50000,50777.9,650,-8.06193e-08,-2.39587e-06,0.00461059,0.0118958,1.0,720.0,78.1198,580.0,720.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-60KTL-CT {480V},480,95.6901,60000,61072.3,730,-1.48067e-07,-2.23566e-05,-0.0034134,-0.00119879,0.88,850.0,83.6607,540.0,850.0,2018-11-01 00:00:00,N +Canadian Solar Inc: CSI-60KTL-GS {480V},480,92.9937,60000,61015.7,650,-1.38907e-07,-2.14638e-05,-0.00234015,-0.00352323,1.0,720.0,93.8702,580.0,720.0,2019-11-15 00:00:00,N +Canadian Solar Inc: CSI-66KTL-GS {480V},480,97.386,66000,67081.6,650,-1.21153e-07,-1.4476e-05,-0.000497373,-6.53285e-05,1.0,720.0,103.202,580.0,720.0,2019-11-15 00:00:00,N +Cherry Solution Co Ltd: CMI-1000S-SA {208V},208,3.76219,994,1031.61,42,-1.44406e-05,-0.000576005,-0.057081,-0.114285,0.11,50.0,24.5622,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-1000S-SA {240V},240,2.19,1062,1102.49,42,-8.6552e-06,-1.78504e-05,0.0783163,0.0812887,0.13,50.0,26.2497,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-1000S-WA {208V},208,3.76219,994,1031.61,42,-1.44406e-05,-0.000576005,-0.057081,-0.114285,0.11,50.0,24.5622,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-1000S-WA {240V},240,2.19,1062,1102.49,42,-8.6552e-06,-1.78504e-05,0.0783163,0.0812887,0.13,50.0,26.2497,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-600S-SA {208V},208,0.863612,608,630.093,42,-2.39392e-06,0.000317364,-0.0711841,0.202925,0.2,50.0,15.0022,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-600S-SA {240V},240,2.91446,604,628.376,42,-3.59857e-05,0.000363132,-0.0745736,-0.0803339,0.7,50.0,14.9613,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-600S-WA {208V},208,0.863612,608,630.093,42,-2.39392e-06,0.000317364,-0.0711841,0.202925,0.2,50.0,15.0022,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-600S-WA {240V},240,2.91446,604,628.376,42,-3.59857e-05,0.000363132,-0.0745736,-0.0803339,0.7,50.0,14.9613,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-800S-SA {208V},208,2.09524,800,834.685,42,-1.29592e-05,-0.000410889,-0.0046904,-0.107218,0.23,50.0,19.8734,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-800S-SA {240V},240,6.46492,800,846.09,42,-8.30495e-05,-0.00131013,0.00583261,-0.0234505,0.23,50.0,20.145,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-800S-WA {208V},208,2.09524,800,834.685,42,-1.29592e-05,-0.000410889,-0.0046904,-0.107218,0.23,50.0,19.8734,35.0,50.0,NaN,N +Cherry Solution Co Ltd: CMI-800S-WA {240V},240,6.46492,800,846.09,42,-8.30495e-05,-0.00131013,0.00583261,-0.0234505,0.23,50.0,20.145,35.0,50.0,NaN,N +Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {208V},208,2.49464,277,291.337,30,-0.00012285,-0.00073679,0.0535639,-0.0181644,0.02,32.0,9.71125,28.0,32.0,2020-02-11 00:00:00,N +Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V},240,2.44266,289,302.901,30,-0.000113061,-0.00100016,0.0474629,-0.0219511,0.06,32.0,10.0967,28.0,32.0,2020-02-11 00:00:00,N +Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {208V},208,5.41222,725,764.711,65,-5.64015e-05,0.000198285,0.027396,0.0144986,0.1,70.0,11.7648,60.0,70.0,2020-02-11 00:00:00,N +Chilicon Power LLC: CP-720-60/72/96-208/240-MC4 {240V},240,5.94225,721,756.124,65,-5.5351e-05,0.000286342,0.0246322,0.0135089,0.1,70.0,11.6327,60.0,70.0,2020-02-11 00:00:00,N +Chint Power Systems America: CPS ECB125KTL-M/US-480 {480V},480,268.672,125000,128603,925,-1.01551e-07,2.04023e-05,0.00109184,-0.000119302,5.8,1100.0,139.03,750.0,1100.0,2025-06-23 00:00:00,N +Chint Power Systems America: CPS ECB200KTL/US-800 {800V},800,847.748,200000,205016,1225,-5.88545e-08,-1.53114e-05,-0.00100878,-0.00102249,5.0,1500.0,167.36,950.0,1500.0,2025-03-03 00:00:00,N +Chint Power Systems America: CPS ECB30KTL-O/US {480V},480,98.0848,30260,31104.3,660,-2.66591e-07,-3.39144e-05,-0.000111579,0.00144434,20.0,800.0,47.1277,450.0,800.0,2020-09-01 00:00:00,N +Chint Power Systems America: CPS ECB625KTL-M/US-480 {480V},480,186.23,62500,64194.8,925,-1.98684e-07,2.33309e-05,0.00271133,0.00103128,6.1,1100.0,69.3998,750.0,1100.0,2025-06-23 00:00:00,N +Chint Power Systems America: CPS ECH114KTL/US {208V},208,58.719,11350,11745.3,370,-1.04785e-06,-9.14968e-07,0.000198225,0.000347577,80.0,480.0,31.7442,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH114KTL/US {240V},240,54.6436,11360,11768.2,370,-1.09348e-06,1.77011e-06,0.000402006,0.00104615,30.0,480.0,31.8059,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH12KTL/US {208V},208,52.014,12000,12418.5,370,-8.86079e-07,-4.47876e-06,0.000904331,0.00122463,80.0,480.0,33.5636,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH12KTL/US {240V},240,52.4431,11990,12413.9,370,-8.60645e-07,-1.19733e-06,-5.08297e-06,0.000131874,60.0,480.0,33.5512,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH76KTL/US {208V},208,44.4561,7570,7837.54,370,-1.65435e-06,-1.24652e-05,-0.00043222,-0.00261195,50.0,480.0,21.1825,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH76KTL/US {240V},240,35.7321,7570,7827.62,370,-5.07252e-07,7.99618e-06,0.000389416,0.00838061,60.0,480.0,21.1557,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH96KTL/US {208V},208,55.5838,9550,9872.48,370,-1.10817e-06,1.37133e-06,0.000179357,0.00063119,60.0,480.0,26.6824,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS ECH96KTL/US {240V},240,54.7466,9540,9875.07,370,-1.32813e-06,8.50319e-06,0.00124886,0.00338645,50.0,480.0,26.6894,200.0,480.0,2025-04-21 00:00:00,Y +Chint Power Systems America: CPS SCA20KTL-DO-R/US-480 {480V},480,29.0146,20000,20437.4,735,-4.90504e-07,-2.78694e-05,-0.00177009,-0.00227291,3.0,850.0,27.806,560.0,850.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCA25KTL-DO-R/US-480 {480V},480,37.6542,25000,25548.1,735,-4.0067e-07,-2.67278e-05,-0.00141828,-0.00199184,3.0,850.0,34.7593,560.0,850.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCA25KTL-DO/US-208 {208V},208,79.0356,25000,25971.3,575,-6.61542e-07,1.5913e-05,0.00180454,0.000250856,2.9,850.0,45.1676,480.0,850.0,2023-02-01 00:00:00,N +Chint Power Systems America: CPS SCA36KTL-DO/US {480V},480,80.1024,36000,36701.7,730,-2.33292e-07,-3.88036e-05,-0.0027293,-0.00119439,10.8,800.0,50.2763,540.0,800.0,2021-01-21 00:00:00,N +Chint Power Systems America: CPS SCA36KTL-DO/US-480 {480V},480,164.186,36000,36877.4,625,-1.6533e-07,-2.49051e-05,-0.000652284,-0.00119063,2.9,850.0,59.0038,400.0,850.0,2023-02-21 00:00:00,N +Chint Power Systems America: CPS SCA50KTL-DO/US-480 {480V},480,96.1458,50000,50831.5,730,-1.44391e-07,-2.42776e-05,-0.00361241,-0.00128939,0.88,850.0,69.6321,480.0,850.0,2023-02-01 00:00:00,N +Chint Power Systems America: CPS SCA60KTL-DO/US-480 {480V},480,96.2303,60000,61067.7,730,-1.5132e-07,-2.46471e-05,-0.00371424,-0.00174062,0.88,850.0,83.6544,540.0,850.0,2023-02-01 00:00:00,N +Chint Power Systems America: CPS SCH100KTL-AIO/US-600 {600V},600,135.723,100000,101581,1000,-8.31355e-08,1.85377e-05,0.00143771,0.000339564,0.33,1300.0,101.581,870.0,1300.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCH100KTL-DO/US-480 {480V},480,139,100000,102265,1000,-1.5077e-07,1.43548e-05,0.00146258,0.000320646,1.6,1300.0,102.265,760.0,1300.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCH100KTL-DO/US-600 {600V},600,115.217,100000,101613,1000,-7.38554e-08,1.84053e-05,0.00184881,0.000271952,4.5,1300.0,101.613,870.0,1300.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCH125KTL-AIO/US-600 {600V},600,148.671,125000,127293,1000,-9.26131e-08,2.06864e-05,0.00167241,0.000650352,0.33,1300.0,127.293,870.0,1300.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCH125KTL-DO/US-600 {600V},600,142.988,125000,127274,1000,-8.73741e-08,1.8891e-05,0.00162599,0.000388063,4.9,1300.0,127.274,870.0,1300.0,2022-06-13 00:00:00,N +Chint Power Systems America: CPS SCH275KTL-DO/US-800 {800V},800,374.601,275000,279186,1190,-2.72273e-08,-1.95906e-05,-0.0018392,-0.000888456,6.5,1300.0,234.61,900.0,1300.0,2022-09-12 00:00:00,N +Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V},800,572.373,320000,325545,1190,-3.89879e-08,-1.1952e-05,-0.00117452,-0.00050443,15.0,1300.0,273.567,880.0,1300.0,2024-07-01 00:00:00,N +Chint Power Systems America: CPS SCH350KTL-DO/US-800 {800V},800,489.047,350000,355761,1190,-2.6158e-08,-9.07399e-06,-0.000875865,-6.97966e-05,15.0,1300.0,298.959,880.0,1300.0,2024-07-01 00:00:00,N +Chint Power Systems America: SCA100K-T-US-480 {480V},480,200.488,100000,101987,720,-9.20771e-08,-2.38199e-05,-0.000992011,-0.000470289,21.54,850.0,141.649,340.0,850.0,NaN,N +Chint Power Systems America: SCA50K-T-US-208 {208V},208,118.158,50000,52123.2,380,-4.25055e-07,-3.6091e-06,0.00020777,-0.000289033,20.0,700.0,137.166,200.0,700.0,2026-04-21 00:00:00,N +Chint Power Systems America: SCH200K-T-US-480 {480V},480,258.712,200000,204663,1000,-5.91739e-08,1.14527e-05,0.00234818,0.00045978,10.0,1300.0,204.663,900.0,1300.0,2025-07-21 00:00:00,N +Chint Power Systems America: SCH250K-T-US-600 {600V},600,346.413,250000,254544,1100,-3.07083e-08,1.46617e-05,0.00154449,0.00252899,15.0,1300.0,231.403,900.0,1300.0,2025-02-03 00:00:00,N +DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {350V},350,879.141,582490,598834,1000,-2.14238e-08,5.05393e-06,0.00178104,-0.000134476,130.0,1500.0,598.834,530.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {415V},415,1077.34,691248,707594,1050,-1.62396e-08,2.91727e-06,0.00144475,-0.000123714,2200.0,1500.0,673.899,630.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {480V},480,1271.78,799592,816212,1145,-1.27048e-08,1.87798e-06,0.00088274,-0.000256302,70.0,1500.0,712.849,800.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {600V},600,1600.01,999576,1.01544e+06,1185,-7.69291e-09,1.0147e-06,0.000552585,-0.000283145,2400.0,1500.0,856.907,900.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {690V},690,1925.33,1146100,1.16222e+06,1250,-6.31677e-09,1.0796e-06,0.000279317,-0.000439996,2400.0,1500.0,929.777,1020.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-1250 Gen5 {800V},800,2359.21,1294180,1.30969e+06,1250,-5.03933e-09,9.29273e-07,0.00025172,-0.000335263,2700.0,1500.0,1047.75,1020.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {480V},480,3922.95,1199640,1.24794e+06,1000,-1.6497e-08,2.46296e-06,-0.00119126,-0.00100359,438.5,1500.0,1247.94,740.0,1500.0,2024-03-21 00:00:00,N +DYNAPOWER COMPANY LLC: CPS-1500 Gen4 {600V},600,11190.4,1498660,1.54487e+06,1200,-1.71039e-08,2.01967e-06,0.000436883,0.000596092,1241.0,1500.0,1287.39,900.0,1500.0,2024-03-21 00:00:00,N +DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {415V},415,3332.34,1353700,1.39706e+06,1100,-6.70691e-09,9.7706e-06,0.00188473,-0.000777716,70.51,1400.0,1270.06,730.0,1400.0,NaN,N +DYNAPOWER COMPANY LLC: CPS-2500 Gen5 {690V},690,6466.48,2212640,2.26188e+06,1250,-4.03775e-09,7.48496e-06,-0.000621734,-0.00174308,44.08,1500.0,1809.5,1150.0,1500.0,NaN,N +DYNAPOWER COMPANY LLC: MPS-100 {480V},480,2872.37,98861,103555,475,-1.87392e-07,6.96482e-05,0.00188056,0.000974351,803.97,600.0,218.01,350.0,600.0,NaN,N +DYNAPOWER COMPANY LLC: MPS-125EHV {480V},480,631.529,123458,126718,1120,-1.55811e-07,1.30668e-05,0.00134928,0.000913942,50.5,1500.0,113.141,740.0,1500.0,2024-08-01 00:00:00,N +DYNAPOWER COMPANY LLC: MPS-250 {480V},480,3386.13,248910,261340,475,-9.81127e-08,4.90526e-05,0.00136724,0.00061834,1638.5,600.0,550.189,350.0,600.0,2018-10-15 00:00:00,N +DYNAPOWER COMPANY LLC: MPS-250HV {480V},480,3357.93,249619,259475,705,-6.35462e-08,2.45062e-05,0.000543062,-0.00225085,437.7,830.0,368.049,580.0,830.0,NaN,N +Darfon Electronics Corp: H5000xxxxxx {240V},240,51.1736,5074,5294.01,360,-3.90585e-06,-3.83796e-05,-0.000772089,-0.00209129,0.43,380.0,14.7056,300.0,380.0,2021-01-11 00:00:00,Y +Darfon Electronics Corp: H5001xxxxxx {240V},240,68.1627,4844,5113.91,360,-8.21782e-06,-4.7707e-05,-0.000517095,-0.000573017,28.48,380.0,14.2053,300.0,380.0,2021-01-11 00:00:00,Y +Darfon Electronics Corp: H7xxxxxx {240V},240,70.3328,9604.01,9949.23,360,-1.98659e-06,-4.02737e-05,-8.63786e-05,0.000983118,26.9,410.0,27.6368,230.0,410.0,NaN,Y +Darfon Electronics Corp: HB51xxxxxx {240V},240,83.1665,4665,5242.52,53,-1.40621e-05,-0.00448279,0.0167008,-0.041837,0.6021,56.5,98.9154,48.0,56.5,2020-12-21 00:00:00,N +Delta Electronics: DES10JB125K01 {480V},480,681.022,125000,128849,900,-1.21314e-07,1.58773e-05,0.00296371,0.000809601,22.4,1000.0,143.166,750.0,1000.0,2020-05-11 00:00:00,N +Delta Electronics: DP350U-US-XX {800V},800,618.364,352401,357843,1150,-3.29435e-08,-1.21175e-05,-0.00116981,-0.000466204,8.64,1330.0,311.168,850.0,1330.0,NaN,N +Delta Electronics: DWE2100-US {480V},480,11920.5,1887740,1.95267e+06,900,-7.06445e-09,2.23687e-05,0.00118707,0.000317026,18.253,1200.0,2169.64,760.0,1200.0,2021-03-01 00:00:00,N +Delta Electronics: DWE2800-US {480V},480,16034.3,2513388,2.60745e+06,900,-5.11853e-09,2.2083e-05,0.00113008,-7.64416e-05,1114.0,1200.0,2897.17,760.0,1200.0,2021-03-01 00:00:00,N +Delta Electronics: DWE4150-EV-US {600V},600,20439,4162102,4.29455e+06,1100,-5.28044e-09,1.90585e-06,0.000418631,-7.75422e-05,1.729,1350.0,3904.14,875.0,1350.0,2024-09-03 00:00:00,N +Delta Electronics: E10-TL-US {208V},208,22.7021,8400,8672.04,380,-1.9318e-06,-3.69756e-06,0.000910449,0.00013325,1.35,480.0,22.8211,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E10-TL-US {240V},240,22.8249,9674,9952.06,380,-1.40061e-06,-1.26498e-05,-0.000385797,-0.000316499,1.38,480.0,26.1896,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E10-TL-US(AC) {208V},208,24.1231,8327.2,8544.74,400,-1.60023e-06,2.06118e-05,0.00415221,0.000524142,2.0,480.0,21.3619,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E10-TL-US(AC) {240V},240,24.0228,9631.8,9849.88,400,-1.29752e-06,1.83766e-05,0.00520564,0.00109403,3.14,480.0,24.6247,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E10_BDI {208V},208,22.7021,8400,8672.04,380,-1.9318e-06,-3.69756e-06,0.000910449,0.00013325,1.35,480.0,22.8211,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E10_BDI {240V},240,22.8249,9674,9952.06,380,-1.40061e-06,-1.26498e-05,-0.000385797,-0.000316499,1.38,480.0,26.1896,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E30-TL {277V},277,69.7064,30488,31033.5,750,-2.68254e-07,-3.04966e-05,-0.00153187,-0.0014978,1.59,830.0,41.378,515.0,830.0,NaN,Y +Delta Electronics: E4-TL-US {208V},208,19.5698,3360,3441.17,380,-2.6255e-06,-1.69879e-05,-0.000316748,0.00185266,1.21,480.0,9.0557,200.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E4-TL-US {240V},240,18.9831,3870,3949.4,380,-1.98389e-06,-3.4004e-05,-0.00161411,0.00251522,1.27,400.0,10.3931,200.0,400.0,2024-04-02 00:00:00,Y +Delta Electronics: E4-TL-US(AC) {208V},208,16.6045,3364,3428.88,400,-2.69803e-06,2.05306e-05,0.00236164,-0.000892042,1.23,480.0,8.5722,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E4-TL-US(AC) {240V},240,18.1911,3888,3948.14,400,-2.11054e-06,-3.04292e-06,0.00262277,-0.00279264,1.28,480.0,9.87035,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E4_BDI {208V},208,28.0737,3341.34,3429.53,380,-2.27339e-06,-3.75088e-06,0.00344498,0.00494045,1.24,480.0,9.02509,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E4_BDI {240V},240,29.3669,3898.18,3991.25,380,-1.91298e-06,-1.22859e-05,0.00237053,0.00228238,1.3,480.0,10.5033,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E6-TL-US {208V},208,23.781,4992,5139.5,380,-3.28827e-06,-2.02173e-05,-0.000679902,4.18472e-05,1.86,480.0,13.525,200.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E6-TL-US {240V},240,23.5202,5760,5916.69,380,-2.51968e-06,-2.73866e-05,-0.00150169,-0.000264594,2.25,480.0,15.5702,200.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E6-TL-US(AC) {208V},208,20.2288,5000,5122.86,400,-3.31767e-06,2.02282e-05,0.00305221,-0.000293555,1.85,480.0,12.8071,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E6-TL-US(AC) {240V},240,22.5232,5000,5100.95,400,-3.05051e-06,3.79211e-07,0.00235776,-0.00168893,2.05,480.0,12.7524,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E6_BDI {208V},208,32.0783,5025,5173.56,380,-3.43123e-06,-4.08096e-05,0.000765297,-0.00449904,3.07,480.0,13.6146,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E6_BDI {240V},240,27.0493,5823,5964.63,380,-1.40102e-06,-1.48296e-05,0.00230624,0.00191633,3.56,480.0,15.6964,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E8 Plus-TL-US {208V},208,26.4676,6676.8,6888.51,380,-1.82955e-06,-4.32451e-05,0.00122167,-0.000318634,3.22,480.0,18.1277,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E8 Plus-TL-US {240V},240,31.5063,7715.97,7932.88,380,-1.67409e-06,-4.03927e-05,0.00338126,0.00130469,2.72,480.0,20.876,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E8 Plus-TL-US(AC) {208V},208,25.4152,6685,6844.6,400,-1.7368e-06,2.20326e-05,0.00465275,0.00116647,3.34,480.0,17.1115,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E8 Plus-TL-US(AC) {240V},240,24.3481,7720,7879.9,400,-1.35637e-06,2.42663e-05,0.0058988,0.00249056,3.21,480.0,19.6998,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E8-TL-US {208V},208,28.6079,6656,6847.28,380,-2.75658e-06,-5.9221e-06,0.00053654,-0.000101998,1.15,480.0,18.0192,270.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E8-TL-US {240V},240,31.1472,7680,7883.3,380,-2.32886e-06,-2.15681e-05,-0.000682522,-0.000912422,1.19,480.0,20.7455,270.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E8-TL-US(AC) {208V},208,24.7851,6500,6656.66,400,-2.55437e-06,2.20994e-05,0.00320486,0.000369373,1.91,480.0,16.6416,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E8-TL-US(AC) {240V},240,24.8924,6494,6622.84,400,-1.97739e-06,1.34749e-05,0.00414528,0.00155226,2.1,480.0,16.5571,350.0,480.0,2024-04-02 00:00:00,N +Delta Electronics: E8_BDI {208V},208,26.4676,6677,6888.72,380,-1.82955e-06,-4.32454e-05,0.00122167,-0.000318634,3.22,480.0,18.1282,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: E8_BDI {240V},240,31.5063,7716,7932.91,380,-1.67409e-06,-4.03927e-05,0.00338126,0.00130469,2.72,480.0,20.8761,280.0,480.0,2024-04-02 00:00:00,Y +Delta Electronics: EPCS-1200US {480V},480,3252.92,1216710,1.24377e+06,1000,-8.75745e-09,8.31271e-06,0.00129626,8.53625e-05,47.294,1500.0,1243.77,720.0,1500.0,NaN,N +Delta Electronics: EPCS-1500US {600V},600,3758.92,1509889,1.54032e+06,1300,-5.36373e-09,3.98184e-06,0.000617108,-5.14481e-05,46.128,1500.0,1184.86,893.0,1500.0,NaN,N +Delta Electronics: EPCS-1725US {690V},690,4372.45,1725451,1.75622e+06,1300,-4.75574e-09,3.14992e-06,0.000631613,4.90251e-05,45.762,1500.0,1350.94,1030.0,1500.0,NaN,N +Delta Electronics: M10-4-TL-US {208V},208,21.5057,8385,8649.49,350,-1.79179e-06,-1.79959e-06,0.00142216,0.000259832,1.35,480.0,24.7128,280.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M10-4-TL-US {240V},240,22.8249,9674,9952.06,380,-1.40061e-06,-1.26498e-05,-0.000385797,-0.000316499,1.38,480.0,26.1896,280.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M10-TL-US {208V},208,36.4006,8360,8633.72,380,-3.10129e-06,-4.3153e-06,0.000560318,-0.000211057,1.35,480.0,22.7203,280.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M10-TL-US {240V},240,38.2819,9620,9910.53,380,-2.54891e-06,-1.76875e-05,-0.000328255,-0.000863007,1.41,480.0,26.0803,280.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M100U_280 {480V},480,105.896,99975,102063,710,-1.28978e-07,-1.05025e-07,0.00380999,0.000979351,3.05,840.0,143.751,550.0,840.0,NaN,N +Delta Electronics: M125HV {600V},600,212.044,124468,126483,1000,-1.10224e-07,7.77413e-06,0.00202181,-0.00020678,37.3404,1200.0,126.483,860.0,1200.0,2020-11-12 00:00:00,N +Delta Electronics: M24U_120 {480V},480,69.9273,26403,26885.2,710,-2.5204e-07,-2.7447e-05,-0.00120299,-0.000929927,2.6,830.0,37.8664,415.0,830.0,2020-03-02 00:00:00,N +Delta Electronics: M24U_121 {480V},480,69.9273,26403,26885.2,710,-2.5204e-07,-2.7447e-05,-0.00120299,-0.000929927,2.6,830.0,37.8664,415.0,830.0,2020-03-02 00:00:00,N +Delta Electronics: M24U_122 {480V},480,69.9273,26403,26885.2,710,-2.5204e-07,-2.7447e-05,-0.00120299,-0.000929927,2.6,830.0,37.8664,415.0,830.0,2020-03-02 00:00:00,N +Delta Electronics: M28U_120 {480V},480,69.8871,30709,31290.2,710,-2.66134e-07,-2.2571e-05,-0.0014743,-0.00143026,2.4,830.0,44.0707,485.0,830.0,2020-03-02 00:00:00,N +Delta Electronics: M28U_121 {480V},480,69.8871,30709,31290.2,710,-2.66134e-07,-2.2571e-05,-0.0014743,-0.00143026,2.4,830.0,44.0707,485.0,830.0,2020-03-02 00:00:00,N +Delta Electronics: M28U_122 {480V},480,69.8871,30709,31290.2,710,-2.66134e-07,-2.2571e-05,-0.0014743,-0.00143026,2.4,830.0,44.0707,485.0,830.0,2020-03-02 00:00:00,N +Delta Electronics: M36U_120 {480V},480,87.1694,39737,40560.9,710,-2.7188e-07,-1.41606e-05,-0.000815412,-0.000410457,2.9,830.0,57.1281,520.0,830.0,2020-11-12 00:00:00,N +Delta Electronics: M36U_121 {480V},480,87.1694,39737,40560.9,710,-2.7188e-07,-1.41606e-05,-0.000815412,-0.000410457,2.9,830.0,57.1281,520.0,830.0,2020-11-12 00:00:00,N +Delta Electronics: M36U_122 {480V},480,87.1694,39737,40560.9,710,-2.7188e-07,-1.41606e-05,-0.000815412,-0.000410457,2.9,830.0,57.1281,520.0,830.0,2020-11-12 00:00:00,N +Delta Electronics: M4-TL-US {208V},208,24.3982,3330,3423.57,380,-4.37436e-06,-3.55978e-05,-0.000287952,7.01847e-06,1.92,480.0,9.00939,180.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M4-TL-US {240V},240,20.5983,3840,3934.77,380,-2.97005e-06,-3.84962e-05,-0.000909085,-0.00115907,2.03,480.0,10.3547,180.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M42U_120 {480V},480,79.801,45972,46973.5,710,-2.46428e-07,-1.30359e-05,-0.00089694,-0.0006876,2.9,830.0,66.1599,545.0,830.0,2020-11-12 00:00:00,N +Delta Electronics: M42U_121 {480V},480,79.801,45972,46973.5,710,-2.46428e-07,-1.30359e-05,-0.00089694,-0.0006876,2.9,830.0,66.1599,545.0,830.0,2020-11-12 00:00:00,N +Delta Electronics: M42U_122 {480V},480,79.801,45972,46973.5,710,-2.46428e-07,-1.30359e-05,-0.00089694,-0.0006876,2.9,830.0,66.1599,545.0,830.0,2020-11-12 00:00:00,N +Delta Electronics: M5-TL-US {208V},208,18.421,4160,4273.34,380,-3.62663e-06,-2.21865e-05,-0.000565373,-0.000445116,1.24,480.0,11.2456,220.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M5-TL-US {240V},240,19.3548,4860,4983.68,380,-2.92406e-06,-3.39077e-05,-0.00155261,-0.00122389,1.26,480.0,13.1149,220.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M6-TL-US {208V},208,23.9686,4990,5137.21,380,-3.29718e-06,-2.00421e-05,-0.000630751,0.000127153,1.86,480.0,13.519,200.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M6-TL-US {240V},240,23.7613,5760,5915.49,380,-2.4921e-06,-2.7511e-05,-0.0014833,-0.00027132,2.25,480.0,15.5671,200.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M60U_120 {480V},480,104.159,65470,66772.6,710,-1.67792e-07,-2.7598e-05,-0.0061363,-0.00352453,2.86303,800.0,94.0459,540.0,800.0,2020-11-12 00:00:00,N +Delta Electronics: M60U_121 {480V},480,104.159,65470,66772.6,710,-1.67792e-07,-2.7598e-05,-0.0061363,-0.00352453,2.86303,800.0,94.0459,540.0,800.0,2020-11-12 00:00:00,N +Delta Electronics: M60U_122 {480V},480,104.159,65470,66772.6,710,-1.67792e-07,-2.7598e-05,-0.0061363,-0.00352453,2.86303,800.0,94.0459,540.0,800.0,2020-11-12 00:00:00,N +Delta Electronics: M60U_260 {480V},480,268.718,59012,60183,710,-1.2219e-07,7.47152e-06,-0.00060395,-9.61202e-05,3.05,900.0,84.7649,390.0,900.0,2024-11-01 00:00:00,N +Delta Electronics: M60U_280 {480V},480,227.633,60019,60929.7,710,-1.33225e-07,2.21492e-06,0.00105344,0.000101395,3.05,840.0,85.8164,550.0,840.0,NaN,N +Delta Electronics: M8-TL-US {208V},208,27.5001,6660,6849.6,380,-2.58375e-06,-5.29465e-06,0.000701842,0.000249969,1.15,480.0,18.0253,270.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M8-TL-US {240V},240,30.5613,7680,7883.78,380,-2.30755e-06,-1.98675e-05,-0.00091642,-0.00117609,1.19,480.0,20.7468,270.0,480.0,2023-02-01 00:00:00,N +Delta Electronics: M80U_120 {480V},480,71.328,82764,84432.9,710,-1.30255e-07,-1.6253e-05,-0.00423873,-0.00102822,2.6,800.0,118.92,600.0,800.0,2020-11-12 00:00:00,N +Delta Electronics: M80U_121 {480V},480,71.328,82764,84432.9,710,-1.30255e-07,-1.6253e-05,-0.00423873,-0.00102822,2.6,800.0,118.92,600.0,800.0,2020-11-12 00:00:00,N +Delta Electronics: M80U_122 {480V},480,71.328,82764,84432.9,710,-1.30255e-07,-1.6253e-05,-0.00423873,-0.00102822,2.6,800.0,118.92,600.0,800.0,2020-11-12 00:00:00,N +Delta Electronics: M80U_280 {480V},480,257.693,80023,81416.2,710,-1.56749e-07,5.03247e-06,0.000798532,5.09288e-05,3.05,840.0,114.671,550.0,840.0,NaN,N +Delta Electronics: PCS125 {480V},480,681.022,125000,128849,900,-1.21314e-07,1.58773e-05,0.00296371,0.000809601,22.4,1000.0,143.166,750.0,1000.0,NaN,N +Delta Electronics: PCS125HV {480V},480,311.029,124312,127304,950,-9.55974e-08,9.35875e-06,0.00186021,0.000489061,19.0,1250.0,134.004,815.0,1250.0,2024-02-12 00:00:00,N +Delta Electronics: PCS2328S-XXX-US {600V},600,7214.01,2327940,2.37631e+06,1300,-4.51616e-09,7.15005e-06,-0.000242725,-0.00161589,695.7,1500.0,1827.93,920.0,1500.0,NaN,N +Delta Electronics: PCS2580X-X00-US {690V},690,6456.29,2582500,2.6264e+06,1300,-4.34565e-09,4.26687e-06,0.00112828,7.8279e-05,336.0,1500.0,2020.31,1040.0,1500.0,NaN,N +Delta Electronics: PCS4300X-X00-US {690V},690,8086.05,4308400,4.38403e+06,1300,-3.09863e-09,3.37643e-06,0.0014969,0.000106623,580.0,1500.0,3372.33,1040.0,1500.0,NaN,N +Delta Electronics: PCS4300X-X01-US {690V},690,7224.37,4009000,4.0763e+06,1300,-2.64098e-09,1.89921e-06,0.00116371,-0.000327018,550.0,1500.0,3135.62,1040.0,1500.0,NaN,N +Delta Electronics: PCSC2782 {690V},690,7370.06,2813660,2.85605e+06,1300,-2.71028e-09,3.67572e-06,0.00072473,0.000136791,477.0,1500.0,2196.96,1040.0,1500.0,NaN,N +Delta Electronics: PCSC3556 {690V},690,5076.27,3570330,3.62873e+06,1300,-2.62436e-09,3.0642e-06,0.000676141,4.18939e-05,477.0,1500.0,2791.33,1040.0,1500.0,NaN,N +Delta Electronics: S12_BDI {208V},208,39.8095,10056.8,10400.4,380,-2.26455e-06,-3.68162e-05,-0.000609407,-0.000734532,16.23,480.0,27.3696,200.0,480.0,2024-08-12 00:00:00,Y +Delta Electronics: S12_BDI {240V},240,38.4173,11588.6,11947.8,380,-1.70407e-06,-4.99163e-05,-0.0019333,-0.0023664,16.48,480.0,31.4415,200.0,480.0,2024-08-12 00:00:00,Y +Delta Electronics: SOLIVIA 38 NA G4 TL {208V},208,14.6325,3320,3414.58,380,-4.57848e-06,-1.21555e-05,-0.000459271,-0.000852248,1.14,500.0,8.98575,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 38 NA G4 TL {240V},240,21.3698,3810,3903.82,380,-3.94533e-06,-2.45433e-05,-9.61268e-05,-0.00117813,1.19,500.0,10.2732,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 52 NA G4 TL {208V},208,31.6177,5200,5335.81,380,-3.01169e-06,-2.0426e-05,-0.000143935,-0.000353957,1.31,500.0,14.0416,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 52 NA G4 TL {240V},240,29.1228,5200,5312.69,380,-1.97459e-06,-2.44946e-05,-0.000240641,-0.00123984,1.42,500.0,13.9808,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 66 NA G4 TL {208V},208,35.0171,6600,6802.75,380,-3.52103e-06,-2.63749e-05,-0.000390192,-0.000993767,1.23,500.0,17.902,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 66 NA G4 TL {240V},240,33.1989,6600,6761.18,380,-2.51834e-06,-2.63813e-05,-0.000371126,-0.000872134,1.45,500.0,17.7926,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 76 NA G4 TL {208V},208,35.0171,6600,6802.75,380,-3.52103e-06,-2.63749e-05,-0.000390192,-0.000993767,1.23,500.0,17.902,100.0,500.0,2020-11-12 00:00:00,N +Delta Electronics: SOLIVIA 76 NA G4 TL {240V},240,33.88,7600,7805.28,380,-2.64648e-06,-3.20577e-05,-0.000494819,-0.00133452,1.43,500.0,20.5402,100.0,500.0,2020-11-12 00:00:00,N +Destin Power Inc: SAVEEN1000-ES02HUS {440V},440,5891.34,1000000,1.01755e+06,830,-9.62533e-09,1.60685e-05,0.00145159,-0.000152219,149.25,900.0,1225.96,740.0,900.0,NaN,N +Dyness Digital Energy Technology Co LTD: TX114K-AM {240V},240,30.371,11519,11972.8,400,-1.80536e-06,-1.25375e-05,-0.00088274,-0.0018236,0.12,490.0,29.932,300.0,490.0,2024-01-22 00:00:00,N +Dyness Digital Energy Technology Co LTD: TX114K-HM {240V},240,20.9766,11498,11926.1,390,-1.37243e-06,-4.53167e-05,-0.00442509,-0.00256857,0.13,500.0,30.5798,200.0,500.0,2024-01-22 00:00:00,Y +Dyness Digital Energy Technology Co LTD: TX5K-AM {240V},240,27.8712,5016,5186.94,400,-2.13305e-06,-5.15102e-05,0.00106593,-0.0010058,0.12,490.0,12.9674,130.0,490.0,2024-01-22 00:00:00,N +Dyness Digital Energy Technology Co LTD: TX5K-HM {240V},240,22.4091,5020,5172.74,390,-1.30651e-06,-4.6053e-05,0.00106597,-0.00196923,0.13,500.0,13.2634,180.0,500.0,2024-01-22 00:00:00,Y +Dyness Digital Energy Technology Co LTD: TX6K-AM {240V},240,27.3055,6028,6235.08,400,-2.00695e-06,-4.89389e-05,-0.000654176,-0.00381834,0.12,490.0,15.5877,160.0,490.0,2024-01-22 00:00:00,N +Dyness Digital Energy Technology Co LTD: TX6K-HM {240V},240,38.8282,6018,6204.02,390,-2.8356e-06,-3.9464e-05,0.000835286,-0.000370529,0.12,500.0,15.9077,210.0,500.0,2024-01-22 00:00:00,Y +Dyness Digital Energy Technology Co LTD: TX76K-AM {240V},240,28.8716,7636,7908.27,400,-1.77881e-06,-3.78086e-05,0.00034217,-0.00280003,0.11,490.0,19.7707,200.0,490.0,2024-01-22 00:00:00,N +Dyness Digital Energy Technology Co LTD: TX76K-HM {240V},240,17.9633,7640,7889.64,390,-1.05689e-06,-4.81558e-05,-0.0012194,-0.00457903,0.12,500.0,20.2299,185.0,500.0,2024-01-22 00:00:00,Y +Dyness Digital Energy Technology Co LTD: TX96K-AM {240V},240,19.6201,9662,10016.6,400,-1.42255e-06,-1.47523e-05,0.000155864,-0.000494532,0.12,490.0,25.0415,250.0,490.0,2024-01-22 00:00:00,N +Dyness Digital Energy Technology Co LTD: TX96K-HM {240V},240,24.3203,9648,9991.49,390,-1.45093e-06,-5.96066e-05,-0.00207775,-0.00340451,0.14,500.0,25.6192,170.0,500.0,2024-01-22 00:00:00,Y +EG4 Electronics LLC: 18KPV-12LV {208V},208,45.8617,10499,10928.4,360,-2.03131e-06,-4.9692e-05,-0.000161767,3.31328e-06,14.5,480.0,30.3567,230.0,480.0,2025-06-02 00:00:00,Y +EG4 Electronics LLC: 18KPV-12LV {240V},240,23.5967,11933,12343.2,360,-8.94297e-07,-4.81999e-05,-0.00130889,-0.00251017,14.29,480.0,34.2867,230.0,480.0,2025-06-02 00:00:00,Y +EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V},208,27.0526,11325,11700.8,360,-1.2316e-06,-4.73891e-05,0.00623137,0.00668652,31.95,440.0,32.5022,250.0,440.0,2025-06-23 00:00:00,Y +EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {240V},240,26.5914,12997,13495.5,360,-1.07915e-06,7.00777e-07,-0.00317168,0.000635055,29.57,440.0,37.4875,250.0,440.0,2025-06-23 00:00:00,Y +EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {208V},208,39.5306,13898.7,14409.5,360,-1.09198e-06,-5.37289e-05,0.0025438,0.00111738,29.36,440.0,40.0263,250.0,440.0,2025-06-23 00:00:00,Y +EG4 Electronics LLC: IV-16000-HYB-AW-FX-xx {240V},240,41.6957,16153.2,16720.5,360,-8.27787e-07,-4.90724e-05,-0.00442787,-0.0043975,29.36,440.0,46.4457,250.0,440.0,2025-06-23 00:00:00,Y +EG4 Electronics LLC: IV-8000-HYB-AW {208V},208,31.3505,7859.95,8164.44,360,-2.04399e-06,-4.28777e-05,-0.00251918,-0.00202171,18.53,480.0,22.679,210.0,480.0,2025-06-11 00:00:00,Y +EG4 Electronics LLC: IV-8000-HYB-AW {240V},240,27.0274,7862.66,8149.67,360,-1.19698e-06,-3.71005e-05,-0.00274351,-0.0034595,18.84,480.0,22.638,210.0,480.0,2025-06-11 00:00:00,Y +EPC Power Corp: 50-100100 {208V},208,4980.98,452600,485837,700,-1.71322e-07,2.23132e-05,0.000554197,-0.000187955,135.78,1000.0,694.053,400.0,1000.0,2024-08-01 00:00:00,N +EPC Power Corp: 50-100100 {480V},480,9773.95,1.03684e+06,1.0866e+06,1000,-6.83018e-08,1.55874e-05,0.000717215,8.54239e-05,311.052,1250.0,1086.6,750.0,1250.0,2024-08-01 00:00:00,N +EPC Power Corp: 50-100100 {690V},690,12427.2,1499860,1.55696e+06,1150,-4.10732e-08,9.42218e-06,1.85515e-07,-0.000216441,449.958,1250.0,1353.88,1050.0,1250.0,2024-08-01 00:00:00,N +EPC Power Corp: 50-100122 {480V},480,1340.08,250190,257648,950,-5.99633e-08,1.24556e-05,0.000823709,0.000454726,20.0,1250.0,271.209,710.0,1250.0,2021-05-03 00:00:00,N +EPC Power Corp: 50-100181 {480V},480,2274.84,1044200,1.07112e+06,1110,-1.79102e-08,4.77364e-06,0.00130574,7.6499e-05,291.17,1500.0,964.97,720.0,1500.0,2024-09-03 00:00:00,Y +EPC Power Corp: 50-100181 {600V},600,2569.43,1304151,1.33177e+06,1225,-1.21438e-08,4.1494e-06,0.000518267,6.45106e-05,248.0,1500.0,1087.16,925.0,1500.0,2024-09-03 00:00:00,Y +EPC Power Corp: 50-100181 {690V},690,2736.99,1504900,1.53424e+06,1330,-8.14075e-09,2.7971e-06,0.00079243,0.000116502,250.08,1500.0,1153.57,1100.0,1500.0,2024-09-03 00:00:00,Y +EPC Power Corp: 50-100195 {480V},480,1926.09,502268,516445,980,-3.2858e-08,1.4816e-05,0.000950522,0.000112525,21.08,1250.0,526.985,710.0,1250.0,2024-08-01 00:00:00,N +EPC Power Corp: 50-100205 {480V},480,1340.08,250190,257648,950,-5.99633e-08,1.24556e-05,0.000823709,0.000454726,20.0,1250.0,271.209,710.0,1250.0,2024-08-01 00:00:00,N +EPC Power Corp: 50-100A-BCDEF-G {480V},480,1537.73,499130,514346,950,-2.70341e-08,3.93446e-05,0.000908591,0.000541661,20.0,1250.0,541.417,710.0,1250.0,2022-01-03 00:00:00,N +EPC Power Corp: 50-200100 {350V},350,1100.88,273231,279799,887.5,-6.91946e-08,1.78316e-05,0.00226243,0.000429641,81.9693,1200.0,315.266,575.0,1200.0,NaN,N +EPC Power Corp: 50-200100 {480V},480,1022.29,375012,381715,992,-3.64802e-08,1.2391e-05,0.00235708,0.000327263,112.504,1200.0,384.793,784.0,1200.0,NaN,N +EPC Power Corp: 50-200100 {600V},600,1501.97,468347,476182,1242.5,-2.55272e-08,1.33507e-05,0.00211036,0.000488785,140.504,1500.0,383.245,985.0,1500.0,NaN,N +EPC Power Corp: 50-200100 {630V},630,1515.28,491262,499311,1267,-2.38846e-08,1.21583e-05,0.00214708,0.000349478,147.379,1500.0,394.089,1034.0,1500.0,NaN,N +EPC Power Corp: 50-200100 {660V},660,1416.44,515072,523065,1291.5,-2.25025e-08,1.17142e-05,0.00220078,0.000415756,154.522,1500.0,405.006,1083.0,1500.0,NaN,N +EPC Power Corp: 50-200100 {690V},690,1360.22,537035,545062,1313.5,-2.03453e-08,1.10543e-05,0.00221083,0.000361831,161.11,1500.0,414.969,1127.0,1500.0,NaN,N +EPC Power Corp: 50-200100 {720V},720,1442.84,561806,569904,1340,-1.92546e-08,9.61621e-06,0.00222115,0.000299559,168.542,1500.0,425.302,1181.0,1500.0,NaN,N +EPC Power Corp: 50-200100 {850V},850,1325.52,663578,671830,1444,-1.33204e-08,7.88432e-06,0.00151049,-0.000319277,199.073,1500.0,465.256,1388.0,1500.0,NaN,N +EPC Power Corp: HY LC12/6-7 {480V},480,652.768,220033,230386,475,-7.3822e-08,-1.40616e-05,0.000899733,-0.000701762,19.2,600.0,485.023,455.0,600.0,NaN,Y +EcoFlow Inc: EF-PCS-24 {208V 115kW},208,76.4496,11443.6,11856.8,370,-1.02343e-06,-4.88908e-05,0.000782453,-0.000250197,115.89,480.0,32.0454,120.0,480.0,2026-06-01 00:00:00,Y +EcoFlow Inc: EF-PCS-24 {208V 24kW},208,78.6658,24291.4,25300.6,400,-7.68176e-07,-3.35787e-05,0.000119567,0.000373249,117.25,480.0,63.2516,320.0,480.0,2026-06-01 00:00:00,Y +EcoFlow Inc: EF-PCS-24 {240V 115kW},240,79.9525,11444.2,11852.2,370,-9.66835e-07,-5.59425e-05,0.000649313,-0.000814609,115.86,480.0,32.033,120.0,480.0,2026-06-01 00:00:00,Y +EcoFlow Inc: EF-PCS-24 {240V 24kW},240,75.9177,24012.3,24819.8,400,-6.57639e-07,-3.09755e-05,0.000336797,-0.000304216,117.14,480.0,62.0496,320.0,480.0,2026-06-01 00:00:00,Y +Energizer Solar: Force 114DC {240V},240,31.9569,11511.9,11849.3,380,-1.12783e-06,-1.27325e-05,0.00200826,0.00262926,27.23,480.0,31.1823,305.0,480.0,2024-05-21 00:00:00,Y +Energizer Solar: Force 38DC {240V},240,41.6963,3713.04,3820.34,380,-1.9049e-06,-3.53592e-05,0.000592471,0.000866572,27.23,480.0,10.0535,204.0,480.0,2024-05-21 00:00:00,Y +Energizer Solar: Force 57DC {240V},240,52.3879,5748.18,5900.24,380,-2.42758e-06,-3.54971e-05,0.00056039,0.000482788,27.23,480.0,15.5269,204.0,480.0,2024-05-21 00:00:00,Y +Energizer Solar: Force 76DC {240V},240,43.4984,7720.34,7930.66,380,-1.39215e-06,-3.03517e-05,0.00147548,0.00160414,27.23,480.0,20.8702,271.0,480.0,2024-05-21 00:00:00,Y +Energizer Solar: Force 96DC {240V},240,41.225,9609.13,9897.09,380,-1.44716e-06,-2.37197e-05,0.000330262,0.00079536,27.23,480.0,26.045,257.0,480.0,2024-05-21 00:00:00,Y +Enphase Energy Inc: IQ6-60-2-US {208V},208,1.22879,230,237.181,32,-4.90807e-05,6.23574e-06,-0.0197464,-0.0646424,0.02,37.0,7.41192,27.0,37.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6-60-2-US {240V},240,0.986078,230,236.019,32,-2.19687e-05,-0.000229328,-0.0311339,-0.21359,0.03,37.0,7.37558,27.0,37.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6-60-5-US {208V},208,1.22879,230,237.181,32,-4.90807e-05,6.23574e-06,-0.0197464,-0.0646424,0.02,37.0,7.41192,27.0,37.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6-60-5-US {240V},240,0.986078,230,236.019,32,-2.19687e-05,-0.000229328,-0.0311339,-0.21359,0.03,37.0,7.37558,27.0,37.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6-60-ACM-US {208V},208,1.22879,230,237.181,32,-4.90807e-05,6.23574e-06,-0.0197464,-0.0646424,0.02,37.0,7.41192,27.0,37.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6-60-ACM-US {240V},240,0.986078,230,236.019,32,-2.19687e-05,-0.000229328,-0.0311339,-0.21359,0.03,37.0,7.37558,27.0,37.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-72-2-US {208V},208,1.63884,280,289.693,36,-6.81829e-05,-1.80074e-05,0.00586674,-0.0293503,0.02,45.0,8.04704,27.0,45.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-72-2-US {240V},240,1.55554,280,288.64,36,-4.21008e-05,-0.000199798,0.000662171,-0.0718989,0.03,45.0,8.01777,27.0,45.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-72-5-US {208V},208,1.63884,280,289.693,36,-6.81829e-05,-1.80074e-05,0.00586674,-0.0293503,0.02,45.0,8.04704,27.0,45.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-72-5-US {240V},240,1.55554,280,288.64,36,-4.21008e-05,-0.000199798,0.000662171,-0.0718989,0.03,45.0,8.01777,27.0,45.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-72-ACM-US {208V},208,1.63884,280,289.693,36,-6.81829e-05,-1.80074e-05,0.00586674,-0.0293503,0.02,45.0,8.04704,27.0,45.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-72-ACM-US {240V},240,1.55554,280,288.64,36,-4.21008e-05,-0.000199798,0.000662171,-0.0718989,0.02,45.0,8.01777,27.0,45.0,2021-03-11 00:00:00,N +Enphase Energy Inc: IQ6PLUS-ACB-LL {240V},240,4.53804,270,283.877,25,-0.000188559,-0.00164832,0.00974591,-0.0395777,0.07,28.0,11.3551,23.0,28.0,2018-10-15 00:00:00,N +Enphase Energy Inc: IQ7-60-2-US {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-2-US {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-5-US {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-5-US {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-ACM-US {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-ACM-US {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-ACM-US-NM {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-ACM-US-NM {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-E-ACM-US {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-E-ACM-US {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-E-ACM-US-NM {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-E-ACM-US-NM {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-E-US {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-E-US {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-M-US {208V},208,1.8,240,247.332,32,-8.95657e-05,-6.03503e-05,0.032105,-0.00525309,0.025,37.0,7.72913,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7-60-M-US {240V},240,1.8528,240,246.634,32,-6.77368e-05,-0.000382007,0.0319504,-0.0336967,0.025,37.0,7.70731,27.0,37.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-66-x-ACM-US-y-z-& {208V},208,1.68215,292.91,304.018,40.5,-7.23709e-05,2.42317e-05,-0.00302213,-0.0168827,0.045,43.0,7.50662,38.0,43.0,2020-11-12 00:00:00,N +Enphase Energy Inc: IQ7A-66-x-ACM-US-y-z-& {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2020-11-12 00:00:00,N +Enphase Energy Inc: IQ7A-66-x-US-& {208V},208,1.68215,292.909,304.017,40.5,-7.23709e-05,2.42331e-05,-0.0030221,-0.0168827,0.045,43.0,7.50659,38.0,43.0,2020-11-12 00:00:00,N +Enphase Energy Inc: IQ7A-66-x-US-& {240V},240,1.80212,348.698,361.323,40.5,-5.76212e-05,4.7478e-06,0.00855034,-0.00969625,0.019,43.0,8.92155,38.0,43.0,2020-11-12 00:00:00,N +Enphase Energy Inc: IQ7A-72-2-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-2-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-5-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-5-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-ACM-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-ACM-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-E-ACM-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-E-ACM-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-E-ACM-US-NM {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-E-ACM-US-NM {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-E-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-E-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-M-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7A-72-M-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-2-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-2-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-5-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-5-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-ACM-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-ACM-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-ACM-US-NM {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-ACM-US-NM {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-ACM-US-RMA {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-ACM-US-RMA {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-E-ACM-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-E-ACM-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-E-ACM-US-NM {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-E-ACM-US-NM {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-E-US {208V},208,1.68215,290,300.946,40.5,-7.23709e-05,2.79794e-05,-0.00302213,-0.0168827,0.045,43.0,7.43076,38.0,43.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7AS-66-E-US {240V},240,1.80212,349,361.641,40.5,-5.76212e-05,4.52234e-06,0.00855034,-0.00969625,0.019,43.0,8.9294,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7GPLUS-72-2-US {240V},240,1.31248,298,307.159,37,-4.53149e-05,-0.000752616,-0.042107,-0.0779671,0.03,45.0,8.30161,29.0,45.0,NaN,N +Enphase Energy Inc: IQ7HS-66-ACM-US {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-09-12 00:00:00,N +Enphase Energy Inc: IQ7HS-66-ACM-US {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-09-12 00:00:00,N +Enphase Energy Inc: IQ7HS-66-ACM-US-NM {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-ACM-US-NM {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-E-ACM-US {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-E-ACM-US {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-E-ACM-US-NM {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-E-ACM-US-NM {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-ACM-US {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-ACM-US {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-ACM-US-NM {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-ACM-US-NM {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-ACM-US-RMA {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-ACM-US-RMA {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-US {208V},208,1.7633,367,380.332,40.5,-6.84318e-05,-0.000237151,-0.0106936,-0.0261868,0.05,43.0,9.39091,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7HS-66-M-US {240V},240,1.69476,384,396.132,40.5,-4.9069e-05,-0.000787873,-0.0110577,-0.0643947,0.06,43.0,9.78105,38.0,43.0,2022-11-01 00:00:00,N +Enphase Energy Inc: IQ7PD-72-2-US {208V},208,1.31676,190,195.646,31,-5.50762e-05,-0.000308134,-0.00926845,-0.108737,0.02,40.0,6.31117,22.0,40.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PD-72-2-US {240V},240,1.31514,190,195.419,31,-2.53507e-05,-0.000476745,-0.0217568,-0.326729,0.02,40.0,6.30384,22.0,40.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PD-84-2-US {208V},208,1.46551,210,216.752,40,-4.15571e-05,0.000116723,0.00942465,-0.0373976,0.017,50.0,5.4188,31.0,50.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PD-84-2-US {240V},240,1.32643,210,215.679,40,-7.18858e-06,0.000131039,0.00440662,-0.331946,0.022,50.0,5.39198,31.0,50.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-2-US {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-2-US {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-5-US {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-5-US {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-ACM-US {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-ACM-US {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-ACM-US-NM {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-ACM-US-NM {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-E-ACM-US {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-E-ACM-US {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-E-ACM-US-NM {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-E-ACM-US-NM {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-E-US {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-E-US {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-M-US {208V},208,1.97565,290,300.806,36,-8.91095e-05,-4.92406e-05,0.0227864,-0.00605926,0.025,45.0,8.35573,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7PLUS-72-M-US {240V},240,1.89885,290,299.04,36,-6.54326e-05,-0.000269406,0.0188955,-0.0278326,0.025,45.0,8.30668,27.0,45.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7X-96-2-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-2-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-5-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-5-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-ACM-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-ACM-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-ACM-US-NM {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-ACM-US-NM {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-E-ACM-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-E-ACM-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-E-ACM-US-NM {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-E-ACM-US-NM {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-E-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-E-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-M-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7X-96-M-US {240V},240,1.30138,315,322.968,60,-2.77377e-05,-2.45904e-05,0.00348523,-0.0377815,0.021,64.0,5.38281,53.0,64.0,2023-06-01 00:00:00,N +Enphase Energy Inc: IQ7XS-96-2-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-2-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-5-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-5-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-ACM-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-ACM-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-ACM-US-NM {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-ACM-US-NM {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-ACM-US-RMA {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-ACM-US-RMA {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-E-ACM-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-E-ACM-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-E-ACM-US-NM {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-E-ACM-US-NM {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-E-US {208V},208,3.57715,315,326.199,54.5,-0.000117822,-0.000144027,0.0100036,-0.00621635,0.021,64.0,5.98531,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ7XS-96-E-US {240V},240,3.78988,315,324.623,54.5,-0.00010419,-0.000300697,0.00923502,-0.0127143,0.027,64.0,5.95638,45.0,64.0,2023-12-21 00:00:00,N +Enphase Energy Inc: IQ8-60-2-US {240V},240,1.61274,240,248.079,32,-8.08474e-05,-0.00132927,0.000266928,-0.0904213,0.029,37.0,7.75246,27.0,37.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8-60-M-US {240V},240,1.25652,240,247.425,32,-7.3616e-05,-0.00131067,-0.0388361,-0.117015,0.023,37.0,7.73204,27.0,37.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8A-72-2-US {240V},240,1.90549,349,362.211,38.5,-8.57267e-05,-0.00124144,-0.00789046,-0.0654277,0.017,45.0,9.40807,32.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8A-72-M-US {240V},240,1.54257,349,360.845,38.5,-6.7206e-05,-0.00097721,-0.0213936,-0.0660921,0.022,45.0,9.3726,32.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8AC-72-2-US {208V},208,1.67585,344,358.773,36.5,-8.5016e-05,-1.60151e-05,-0.0193757,-0.0216117,0.022,45.0,9.82939,28.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8AC-72-2-US {240V},240,1.71726,349,361.745,36.5,-6.5231e-05,-0.000308709,-0.041778,-0.0524006,0.03,45.0,9.91082,28.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8AC-72-M-DOM-US {208V},208,1.84099,345,359.459,36.5,-8.35094e-05,-0.000220805,-0.0156207,-0.0377566,0.028,45.0,9.84818,28.0,45.0,NaN,N +Enphase Energy Inc: IQ8AC-72-M-DOM-US {240V},240,2.03448,349,361.39,36.5,-6.33926e-05,-0.000491029,-0.0241159,-0.0743962,0.031,45.0,9.90109,28.0,45.0,NaN,N +Enphase Energy Inc: IQ8AC-72-M-F-US {208V},208,1.84099,345,359.459,36.5,-8.35094e-05,-0.000220805,-0.0156207,-0.0377566,0.028,45.0,9.84818,28.0,45.0,NaN,N +Enphase Energy Inc: IQ8AC-72-M-F-US {240V},240,2.03448,349,361.39,36.5,-6.33926e-05,-0.000491029,-0.0241159,-0.0743962,0.031,45.0,9.90109,28.0,45.0,NaN,N +Enphase Energy Inc: IQ8AC-72-M-US {208V},208,1.95535,345,359.525,36.5,-8.88421e-05,-0.000183681,-0.0116429,-0.0314269,0.345,45.0,9.85001,28.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8AC-72-M-US {240V},240,2.18141,349,361.45,36.5,-6.98736e-05,-0.000395409,-0.0136881,-0.0507526,0.036,45.0,9.90275,28.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8D-72-E-US {208V},208,2.62905,640,659.194,77.5,-3.36531e-05,-0.000132589,-0.00676737,-0.0170258,0.04265,95.0,8.50573,60.0,95.0,2022-08-01 00:00:00,N +Enphase Energy Inc: IQ8D-BAT {208V},208,8.53714,554.919,571.478,73.5,-6.23034e-05,-0.000193005,0.00516965,-0.00959855,0.033,87.0,7.77521,60.0,87.0,2025-07-11 00:00:00,N +Enphase Energy Inc: IQ8D-BAT {240V},240,9.7268,638.771,656.816,73.5,-5.38758e-05,-0.000357765,0.0030665,-0.0174357,0.0579,87.0,8.93628,60.0,87.0,2025-07-11 00:00:00,N +Enphase Energy Inc: IQ8D-BAT-240 {240V},240,9.7268,638.771,656.816,73.5,-5.38758e-05,-0.000357765,0.0030665,-0.0174357,0.0579,87.0,8.93628,60.0,87.0,2024-01-02 00:00:00,N +Enphase Energy Inc: IQ8D-BAT-DOM {208V},208,8.53714,554.919,571.478,73.5,-6.23034e-05,-0.000193005,0.00516965,-0.00959855,0.033,87.0,7.77521,60.0,87.0,NaN,N +Enphase Energy Inc: IQ8D-BAT-DOM {240V},240,9.7268,638.771,656.816,73.5,-5.38758e-05,-0.000357765,0.0030665,-0.0174357,0.0579,87.0,8.93628,60.0,87.0,2024-12-23 00:00:00,N +Enphase Energy Inc: IQ8H-208-72-2-US {208V},208,1.86146,360,375.897,40.5,-9.46382e-05,-0.00054556,0.000544876,-0.0305963,0.014,45.0,9.2814,36.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8H-208-72-M-US {208V},208,1.6713,359,372.208,40.5,-7.55974e-05,-0.000182422,0.0031406,-0.0224599,0.015,45.0,9.19032,36.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8H-240-72-2-US {240V},240,1.95988,380,393.464,40.5,-7.12943e-05,-0.000911717,-0.001953,-0.0509686,0.03,45.0,9.71517,36.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8H-240-72-M-US {240V},240,1.63034,380,393.35,40.5,-6.6118e-05,-0.000859806,-0.0224805,-0.061797,0.022,45.0,9.71236,36.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8H-3P-72-E-US {208V},208,2.12045,380,391.294,37,-4.6045e-05,-0.00114447,-0.00596774,-0.0976148,0.052,45.0,10.5755,28.5,45.0,2025-08-01 00:00:00,N +Enphase Energy Inc: IQ8H-3P-72-M-US {208V},208,2.12045,380,391.294,37,-4.6045e-05,-0.00114447,-0.00596774,-0.0976148,0.052,45.0,10.5755,28.5,45.0,2025-07-21 00:00:00,N +Enphase Energy Inc: IQ8HC-72-2-US {208V},208,1.75552,359,374.933,37,-9.07116e-05,4.19341e-05,-0.00805437,-0.0140879,0.026,45.0,10.1333,29.5,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8HC-72-2-US {240V},240,1.59349,380,394.67,37,-6.64325e-05,-0.000222906,-0.0109932,-0.0297506,0.022,45.0,10.6668,29.5,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8HC-72-M-DOM-US {208V},208,3.63971,360,375.619,37,-0.00012686,-0.00010341,0.0126603,-0.00545434,0.081,45.0,10.1519,29.5,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8HC-72-M-DOM-US {240V},240,1.59349,380,394.67,37,-6.64325e-05,-0.000222906,-0.0109932,-0.0297506,0.022,45.0,10.6668,29.5,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8HC-72-M-US {208V},208,2.09156,360,375.806,37,-9.39092e-05,-0.000131313,-0.0122668,-0.0251103,0.019,45.0,10.1569,29.5,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8HC-72-M-US {240V},240,2.26539,378,392.209,37,-7.38526e-05,-0.000307511,-0.0202514,-0.0427777,0.024,45.0,10.6002,29.5,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8M-72-2-US {240V},240,1.74113,325,336.69,37.5,-8.22632e-05,-0.00122886,-0.00228181,-0.063463,0.033,45.0,8.9784,30.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8M-72-M-US {240V},240,1.5093,325,335.406,37.5,-6.82223e-05,-0.000988544,-0.0236435,-0.0693396,0.021,45.0,8.94415,30.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8MC-72-2-US {208V},208,1.35827,309,321.449,35,-8.00578e-05,-0.000173812,-0.0198998,-0.0321716,0.025,45.0,9.18426,25.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8MC-72-2-US {240V},240,1.56217,320,331.475,35,-6.69713e-05,-0.000526451,-0.0430187,-0.0686804,0.033,45.0,9.47072,25.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8MC-72-M-DOM-US {208V},208,1.75354,310,322.931,35,-9.37482e-05,-0.000317721,-0.00698231,-0.0350552,0.027,45.0,9.22661,25.0,45.0,NaN,N +Enphase Energy Inc: IQ8MC-72-M-DOM-US {240V},240,1.99063,320,331.569,35,-7.20754e-05,-0.00064302,-0.0100771,-0.0577681,0.031,45.0,9.4734,25.0,45.0,NaN,N +Enphase Energy Inc: IQ8MC-72-M-F-US {208V},208,1.75354,310,322.931,35,-9.37482e-05,-0.000317721,-0.00698231,-0.0350552,0.027,45.0,9.22661,25.0,45.0,NaN,N +Enphase Energy Inc: IQ8MC-72-M-F-US {240V},240,1.99063,320,331.569,35,-7.20754e-05,-0.00064302,-0.0100771,-0.0577681,0.031,45.0,9.4734,25.0,45.0,NaN,N +Enphase Energy Inc: IQ8MC-72-M-US {208V},208,1.82998,310,322.482,35,-9.21506e-05,-0.000277781,-0.00830433,-0.0358333,0.027,45.0,9.21377,25.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8MC-72-M-US {240V},240,2.02419,320,331.129,35,-6.86966e-05,-0.000560083,-0.0146791,-0.0641225,0.031,45.0,9.46084,25.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8P-3P-72-E-DOM-US {208V},208,2.37048,475,488.638,45,-3.9779e-05,-0.000610032,-0.00231171,-0.0591866,0.056,53.0,10.8586,35.5,53.0,2025-08-01 00:00:00,N +Enphase Energy Inc: IQ8P-3P-72-E-US {208V},208,2.37048,475,488.638,45,-3.9779e-05,-0.000610032,-0.00231171,-0.0591866,0.056,53.0,10.8586,35.5,53.0,2025-08-01 00:00:00,N +Enphase Energy Inc: IQ8P-3P-72-M-US {208V},208,2.37048,475,488.638,45,-3.9779e-05,-0.000610032,-0.00231171,-0.0591866,0.056,53.0,10.8586,35.5,53.0,2025-07-21 00:00:00,N +Enphase Energy Inc: IQ8P-72-2-US {240V},240,2.60972,475,488.979,45.5,-3.52658e-05,-0.000760188,-0.010107,-0.0786731,0.063,55.0,10.7468,36.0,55.0,2025-09-22 00:00:00,N +Enphase Energy Inc: IQ8P-72-M-US {240V},240,2.60972,475,488.979,45.5,-3.52658e-05,-0.000760188,-0.010107,-0.0786731,0.063,55.0,10.7468,36.0,55.0,2025-09-22 00:00:00,N +Enphase Energy Inc: IQ8PLUS-72-2-US {240V},240,1.65341,290,299.127,36,-6.94403e-05,-0.00102349,0.00448488,-0.0651307,0.03,45.0,8.30909,27.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8PLUS-72-M-DOM-US {240V},240,1.65341,290,299.127,36,-6.94403e-05,-0.00102349,0.00448488,-0.0651307,0.03,45.0,8.30909,27.0,45.0,NaN,N +Enphase Energy Inc: IQ8PLUS-72-M-F-US {240V},240,1.65341,290,299.127,36,-6.94403e-05,-0.00102349,0.00448488,-0.0651307,0.03,45.0,8.30909,27.0,45.0,NaN,N +Enphase Energy Inc: IQ8PLUS-72-M-US {240V},240,1.41335,290,299.813,36,-7.50729e-05,-0.00120336,-0.0267771,-0.0860767,0.025,45.0,8.32815,27.0,45.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-80-E-US {208V},208,4.06363,359,374.222,51.5,-0.000112331,1.33552e-05,0.012802,0.000106554,0.012,60.0,7.26645,43.0,60.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-80-E-US {240V},240,4.47272,379,392.3,51.5,-9.15783e-05,-2.39419e-05,0.00826831,-0.00610093,0.026,60.0,7.61747,43.0,60.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-80-M-DOM-US {208V},208,4.06363,359,374.222,51.5,-0.000112331,1.33552e-05,0.012802,0.000106554,0.012,60.0,7.26645,43.0,60.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-80-M-DOM-US {240V},240,4.47272,379,392.3,51.5,-9.15783e-05,-2.39419e-05,0.00826831,-0.00610093,0.026,60.0,7.61747,43.0,60.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-80-M-US {208V},208,1.91224,360,374.724,51.5,-6.96039e-05,-6.35023e-05,0.00419604,-0.0178938,0.012,60.0,7.27619,43.0,60.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-80-M-US {240V},240,2.19158,380,393.712,51.5,-5.75976e-05,-0.000196964,0.000626267,-0.0317707,0.029,60.0,7.64488,43.0,60.0,2025-06-23 00:00:00,N +Enphase Energy Inc: IQ8X-BAT-US {240V},240,4.99638,315,323.997,63,-9.01645e-05,7.54785e-06,0.00451508,-0.0100292,0.024,73.5,5.14281,52.5,73.5,2024-11-12 00:00:00,N +Enphase Energy Inc: IQ8X-BAT-US-NB {240V},240,4.99638,315,323.997,63,-9.01645e-05,7.54785e-06,0.00451508,-0.0100292,0.024,73.5,5.14281,52.5,73.5,2024-11-12 00:00:00,N +Enphase Energy Inc: IQ9N-3P-277-A-DOM-US {277V},277,2.07089,427,438.569,36.5,-3.72811e-05,-0.000404189,-0.0104233,-0.070789,0.2,45.0,12.0156,28.0,45.0,2026-03-02 00:00:00,N +Enphase Energy Inc: IQ9N-3P-277-A-US {277V},277,2.07089,427,438.569,36.5,-3.72811e-05,-0.000404189,-0.0104233,-0.070789,0.2,45.0,12.0156,28.0,45.0,2026-03-02 00:00:00,N +Enphase Energy Inc: IQ9N-A-DOM-US {208V},208,1.52417,405,419.256,36.5,-6.42705e-05,-0.000162942,-0.00561202,-0.0257142,0.063,45.0,11.4865,28.0,45.0,2026-06-22 00:00:00,N +Enphase Energy Inc: IQ9N-A-DOM-US {240V},240,1.65506,427,441.096,36.5,-5.45554e-05,-0.000527818,-0.00493774,-0.0437334,0.054,45.0,12.0848,28.0,45.0,2026-06-22 00:00:00,N +Enphase Energy Inc: IQ9N-A-DOM-US-HPB {208V},208,1.75226,415,429.657,37,-6.37622e-05,0.000116178,-0.00397202,-0.0122913,0.051,45.0,11.6124,30.0,45.0,2026-06-22 00:00:00,N +Enphase Energy Inc: IQ9N-A-DOM-US-HPB {240V},240,1.90622,440,453.513,37,-4.74472e-05,-0.000165039,0.00346221,-0.0308372,0.069,45.0,12.2571,30.0,45.0,2026-06-22 00:00:00,N +Enphase Energy Inc: IQ9N-A-US {208V},208,1.52417,405,419.256,36.5,-6.42705e-05,-0.000162942,-0.00561202,-0.0257142,0.063,45.0,11.4865,28.0,45.0,2026-06-22 00:00:00,N +Enphase Energy Inc: IQ9N-A-US {240V},240,1.65506,427,441.096,36.5,-5.45554e-05,-0.000527818,-0.00493774,-0.0437334,0.054,45.0,12.0848,28.0,45.0,2026-06-22 00:00:00,N +Enphase Energy Inc: IQ9S-3P-277-B-DOM-US {277V},277,3.2464,548,562.24,43.5,-2.39746e-05,-9.67696e-05,-0.00249662,-0.0516705,0.22,55.0,12.9251,32.0,55.0,NaN,N +Enphase Energy Inc: IQ9S-3P-277-B-US {277V},277,3.2464,548,562.24,43.5,-2.39746e-05,-9.67696e-05,-0.00249662,-0.0516705,0.22,55.0,12.9251,32.0,55.0,NaN,N +Enphase Energy Inc: IQBATTERY-10C-1P-NA {240V},240,156.457,7080,7317.28,77,-6.08295e-06,-0.000146044,0.0040512,-0.0137935,0.62,84.0,95.0296,70.0,84.0,2026-01-21 00:00:00,N +Enphase Energy Inc: IQBATTERY-10CS-1P-NA {240V},240,156.342,7080,7316.95,77,-6.06943e-06,-0.000145425,0.00402026,-0.0139158,0.62,84.0,95.0253,70.0,84.0,NaN,N +Enphase Energy Inc: S230-60-LL-x {208V},208,0.773997,220,227.135,32,-3.84259e-05,0.000183875,-0.00788438,-0.0424842,0.051,37.0,7.09796,27.0,37.0,2018-10-15 00:00:00,N +Enphase Energy Inc: S230-60-LL-x {240V},240,0.636657,220,226.046,32,7.55851e-06,0.000186038,-0.0403846,0.52793,0.051,37.0,7.06394,27.0,37.0,2018-10-15 00:00:00,N +Enphase Energy Inc: S280-60-LL-x {208V},208,1.16882,270,280.683,32,-6.48748e-05,8.77148e-05,-0.00681109,-0.0339385,0.051,37.0,8.77134,27.0,37.0,2018-10-15 00:00:00,N +Enphase Energy Inc: S280-60-LL-x {240V},240,1.04902,270,278.458,32,-3.7558e-05,7.50289e-05,-0.0128286,-0.0813535,0.062,37.0,8.70181,27.0,37.0,2018-10-15 00:00:00,N +Enphase Energy Inc: XACM-IQ7-LR6-60PB-300M {208V},208,1.79403,240,247.341,32,-8.95888e-05,-6.12593e-05,0.0321343,-0.00526443,0.025,37.0,7.72941,27.0,37.0,2022-10-03 00:00:00,N +Enphase Energy Inc: XACM-IQ7-LR6-60PB-300M {240V},240,1.84053,240,246.65,32,-6.81883e-05,-0.000387713,0.0319504,-0.0336968,0.025,37.0,7.70781,27.0,37.0,2022-10-03 00:00:00,N +Enphase Energy Inc: XACM-IQ7-LR6-60PB-305M {208V},208,1.79403,240,247.341,32,-8.95888e-05,-6.12593e-05,0.0321343,-0.00526443,0.025,37.0,7.72941,27.0,37.0,2022-10-03 00:00:00,N +Enphase Energy Inc: XACM-IQ7-LR6-60PB-305M {240V},240,1.84053,240,246.65,32,-6.81883e-05,-0.000387713,0.0319504,-0.0336968,0.025,37.0,7.70781,27.0,37.0,2022-10-03 00:00:00,N +Eternalplanet Energy Co Ltd: HNA2-S11G6 {240V},240,41.715,11349,11894.4,375,-2.33768e-06,-2.33651e-05,0.000247048,-0.000659129,14.23,480.0,31.7184,250.0,480.0,2026-01-12 00:00:00,Y +Eternalplanet Energy Co Ltd: HNA2-S11G7 {240V},240,41.715,11349,11894.4,375,-2.33768e-06,-2.33651e-05,0.000247048,-0.000659129,14.23,480.0,31.7184,250.0,480.0,2026-01-12 00:00:00,Y +Expert Computer Int'l Inc: ExpertPower 10KW Hybrid Inverter {240V},240,78.834,9018.6,9411.56,360,-1.27312e-06,-6.82184e-06,0.0021947,-0.000233269,4.0,500.0,26.1432,285.0,500.0,NaN,Y +FOXESS CO LTD: AC1-114-US {240V},240,47.3173,11439.7,11789.5,360,-1.27449e-06,7.91074e-06,0.00155495,0.0017143,27.23,460.0,32.7487,280.0,460.0,2024-02-12 00:00:00,N +FOXESS CO LTD: AC1-38-US {240V},240,52.8322,3737.95,3860.78,360,-2.38656e-06,-4.13e-05,0.000252362,-0.00213281,27.23,460.0,10.7244,95.0,460.0,2024-02-12 00:00:00,N +FOXESS CO LTD: AC1-57-US {240V},240,51.9259,5723.48,5893.22,360,-1.48895e-06,-2.87078e-05,-4.99286e-05,-0.00192543,27.23,460.0,16.3701,140.0,460.0,2024-02-12 00:00:00,N +FOXESS CO LTD: AC1-76-US {240V},240,52.1434,7564.11,7786.04,360,-1.33118e-06,-1.79763e-05,-0.000352571,-0.00160228,27.23,460.0,21.6279,190.0,460.0,2024-02-12 00:00:00,N +FOXESS CO LTD: AC1-96-US {240V},240,53.5451,9418.61,9703.01,360,-1.36353e-06,-7.38425e-06,0.000257796,-0.000149619,27.23,460.0,26.9528,235.0,460.0,2024-02-12 00:00:00,N +FOXESS CO LTD: AIO-AC1-114-US {240V},240,46.9906,11339.3,11697.2,380,-1.31178e-06,2.10176e-06,0.000571526,0.000323925,13.34883411,500.0,30.7822,257.0,500.0,NaN,N +FOXESS CO LTD: AIO-AC1-38-US {240V},240,53.293,3781.78,3913.2,360,-3.40425e-06,-4.32417e-05,-0.000100787,-0.00389288,13.34883411,460.0,10.87,85.0,460.0,NaN,N +FOXESS CO LTD: AIO-AC1-57-US {240V},240,56.6365,5698.04,5876.2,360,-2.53721e-06,-2.4408e-05,-0.000130044,-0.00110139,13.34883411,460.0,16.3228,122.0,460.0,NaN,N +FOXESS CO LTD: AIO-AC1-76-US {240V},240,51.9443,7593.16,7813.8,360,-1.45736e-06,-2.80913e-07,-0.000373361,-0.00170583,13.34883411,460.0,21.705,158.0,460.0,NaN,N +FOXESS CO LTD: AIO-AC1-96-US {240V},240,42.8784,9584.86,9868.3,360,-1.03818e-06,-3.28864e-06,-0.00125795,-0.00304778,13.34883411,460.0,27.4119,200.0,460.0,NaN,N +FOXESS CO LTD: AIO-H1-114-US {240V},240,33.2255,11361.2,11690.6,380,-1.20376e-06,-1.15512e-05,0.000140397,-0.000317075,13.34883411,500.0,30.7646,257.0,500.0,NaN,Y +FOXESS CO LTD: AIO-H1-38-US {240V},240,38.327,3797.22,3909.04,380,-1.89026e-06,-3.30986e-05,0.000670048,0.0026932,13.34883411,500.0,10.287,204.0,500.0,NaN,Y +FOXESS CO LTD: AIO-H1-57-US {240V},240,48.1573,5686.6,5841,380,-2.10202e-06,-3.81272e-05,-0.000167274,-0.00184997,13.34883411,500.0,15.371,204.0,500.0,NaN,Y +FOXESS CO LTD: AIO-H1-76-US {240V},240,26.383,7585.68,7776.64,380,-1.05642e-06,4.5506e-06,0.00115956,0.00374665,13.34883411,500.0,20.4648,271.0,500.0,NaN,Y +FOXESS CO LTD: AIO-H1-96-US {240V},240,30.2203,9575.24,9841.75,380,-1.3624e-06,-9.43497e-06,-0.000236273,-0.00112145,13.34883411,500.0,25.8993,257.0,500.0,NaN,Y +FOXESS CO LTD: H1-114-US {240V},240,31.9569,11511.9,11849.3,380,-1.12783e-06,-1.27325e-05,0.00200826,0.00262926,27.23,480.0,31.1823,305.0,480.0,2024-02-12 00:00:00,Y +FOXESS CO LTD: H1-38-US {240V},240,41.6963,3713.04,3820.34,380,-1.9049e-06,-3.53592e-05,0.00059247,0.000866563,27.23,480.0,10.0535,204.0,480.0,2024-02-12 00:00:00,Y +FOXESS CO LTD: H1-57-US {240V},240,52.3879,5748.18,5900.24,380,-2.42758e-06,-3.54971e-05,0.000560392,0.000482792,27.23,480.0,15.5269,204.0,480.0,2024-02-12 00:00:00,Y +FOXESS CO LTD: H1-76-US {240V},240,43.4983,7720.34,7930.66,380,-1.39215e-06,-3.03517e-05,0.00147548,0.00160414,27.23,480.0,20.8702,271.0,480.0,2024-02-12 00:00:00,Y +FOXESS CO LTD: H1-96-US {240V},240,41.225,9609.13,9897.09,380,-1.44716e-06,-2.37197e-05,0.00033026,0.000795358,27.23,480.0,26.045,257.0,480.0,2024-02-12 00:00:00,Y +FOXESS CO LTD: M1-1000-NA {208V},208,6.92769,1004,1060.15,42,-3.33628e-05,0.000147158,-0.00984194,-0.0138587,0.312,50.0,25.2418,35.0,50.0,NaN,N +FOXESS CO LTD: M1-1000-NA {240V},240,5.83539,1005,1056.49,42,-2.23074e-05,-0.000101201,-0.0210817,-0.0571561,0.415,50.0,25.1545,35.0,50.0,NaN,N +FOXESS CO LTD: M1-1200-NA {240V},240,5.04209,1201,1263.93,42,-1.55965e-05,0.000450755,0.0392608,0.0404137,0.416,50.0,30.0936,35.0,50.0,NaN,N +FOXESS CO LTD: M1-600-NA {208V},208,3.27935,607,636.701,42,-1.88811e-05,0.000228966,-0.00910361,-0.0282886,0.312,50.0,15.1596,35.0,50.0,NaN,N +FOXESS CO LTD: M1-800-NA {208V},208,4.60909,814,852.577,42,-1.93081e-05,5.55852e-05,0.0363542,0.0174242,0.312,50.0,20.2994,35.0,50.0,NaN,N +FOXESS CO LTD: M1-800-NA {240V},240,4.46972,814,852.857,42,-1.49611e-05,0.000295634,0.026467,0.0304564,0.416,50.0,20.3061,35.0,50.0,NaN,N +Fengfan Co Ltd Power Supply Branch: SPT-OMOBFP1-A-6KW {120V},120,109.648,6017.66,6364.83,370,-3.02432e-06,5.95113e-06,0.00115198,-0.000174417,43.0,500.0,17.2022,250.0,500.0,NaN,Y +Fortress Power LLC: Avalon HV PC100 {240V},240,54.9958,10000.7,10268.9,380,-8.55833e-07,-1.50649e-05,0.000162207,-0.00418904,16.38,450.0,27.0235,230.0,450.0,NaN,Y +Fortress Power LLC: Avalon HV PC114 {240V},240,19.4646,11406,11710.1,380,1.7412e-07,-1.32033e-05,-0.00860433,0.0360537,15.36,450.0,30.8161,245.0,450.0,NaN,Y +Fortress Power LLC: Avalon HV PC50 {240V},240,12.5374,5001.66,5166.3,370,-1.38737e-07,-3.46103e-06,-0.00260009,-0.0352677,18.83,450.0,13.963,140.0,450.0,NaN,Y +Fortress Power LLC: Avalon HV PC76 {240V},240,19.7077,7604.3,7806.36,380,9.24483e-08,-2.37941e-06,0.00154006,0.00377546,16.33,450.0,20.5431,175.0,450.0,NaN,Y +Fortress Power LLC: FP-ENVY-10K {208V},208,33.5377,9757.73,10152.7,360,-1.68485e-06,-4.23266e-05,-0.00245204,-0.000328366,14.8,480.0,28.202,210.0,480.0,2025-05-12 00:00:00,Y +Fortress Power LLC: FP-ENVY-10K {240V},240,37.5127,9758.58,10151.7,360,-1.6392e-06,-4.82755e-05,-0.000632676,-0.00104769,14.3,480.0,28.1993,210.0,480.0,2025-05-12 00:00:00,Y +Fortress Power LLC: FP-ENVY-12K {208V},208,46.0029,10499.4,10929.3,360,-2.04177e-06,-4.97058e-05,-0.000136348,3.84323e-05,14.5,480.0,30.3591,230.0,480.0,2025-02-11 00:00:00,Y +Fortress Power LLC: FP-ENVY-12K {240V},240,23.4978,11932.6,12342.9,360,-8.92501e-07,-4.80042e-05,-0.00121621,-0.0023988,14.29,480.0,34.2857,230.0,480.0,2025-02-11 00:00:00,Y +Fortress Power LLC: FP-ENVY-8K {208V},208,31.3505,7859.95,8164.44,360,-2.04398e-06,-4.28777e-05,-0.00251919,-0.00202171,18.53,480.0,22.679,210.0,480.0,2025-05-12 00:00:00,Y +Fortress Power LLC: FP-ENVY-8K {240V},240,27.0274,7862.66,8149.67,360,-1.19698e-06,-3.71005e-05,-0.00274351,-0.0034595,18.84,480.0,22.638,210.0,480.0,2025-05-12 00:00:00,Y +Fortress Power LLC: FP-Envy 15K {208V},208,39.4771,13899,14409.8,360,-1.08973e-06,-5.34221e-05,0.00257429,0.00116755,29.36,440.0,40.0273,250.0,440.0,2026-01-12 00:00:00,Y +Fortress Power LLC: FP-Envy 15K {240V},240,41.5179,16153,16720.1,360,-8.2465e-07,-4.92855e-05,-0.00445832,-0.00445344,29.36,440.0,46.4447,250.0,440.0,2026-01-12 00:00:00,Y +Fortress Power LLC: FP-Envy Duo 21 {208V},208,39.4771,13899,14409.8,360,-1.08973e-06,-5.34221e-05,0.00257429,0.00116755,29.36,440.0,40.0273,250.0,440.0,2026-01-12 00:00:00,Y +Fortress Power LLC: FP-Envy Duo 21 {240V},240,41.5179,16153,16720.1,360,-8.2465e-07,-4.92855e-05,-0.00445832,-0.00445344,29.36,440.0,46.4447,250.0,440.0,2026-01-12 00:00:00,Y +Fortress Power LLC: FP-Nano-30k-L {208V},208,151.045,25883.5,26603.9,675,-1.9297e-07,-4.88468e-06,0.00319636,0.00408514,57.3,850.0,39.4131,500.0,850.0,2026-05-21 00:00:00,Y +Fortress Power LLC: FP-Nano-30k-L {220V},220,152.593,27379,28103.2,675,-1.41595e-07,-8.95756e-06,0.00297313,0.0125414,67.5,850.0,41.6344,500.0,850.0,2026-05-21 00:00:00,Y +Fortress Power LLC: FP-Nano-30k-L {240V},240,166.661,29834.2,30631.4,675,-1.61777e-07,-8.69442e-06,0.00305494,0.0103769,70.7,850.0,45.3798,500.0,850.0,2026-05-21 00:00:00,Y +Fortress Power LLC: FP-Nano-30k-N {480V},480,181.699,29884.7,30671.3,675,-2.56628e-07,-8.95856e-06,0.00233231,0.00394592,54.5,850.0,45.439,500.0,850.0,2026-05-21 00:00:00,Y +Fortress Power LLC: FP-Nano-40k-N {480V},480,169.229,39844,40916,675,-2.13109e-07,2.29322e-06,0.000528769,0.00314213,70.0,850.0,60.6163,500.0,850.0,2026-05-21 00:00:00,Y +Fortress Power LLC: FP-Nano-50k-N {480V},480,208.565,49803.4,51129,725,-2.06513e-07,-1.13139e-05,-0.00135628,-0.00228895,76.0,850.0,70.5228,600.0,850.0,2026-05-21 00:00:00,Y +Fortress Power LLC: FP-Nano-60k-N {480V},480,166.871,59763,61409.5,725,-1.74792e-07,-4.53084e-06,0.000604975,-7.43048e-05,76.0,850.0,84.7028,600.0,850.0,2026-05-21 00:00:00,Y +FranklinWH Energy Storage Inc: aPower Syyy {208V},208,50.7726,9785.08,10040.9,400,-1.45208e-06,-2.25461e-05,-0.00043303,-0.000452928,58.7,480.0,25.1023,250.0,480.0,NaN,Y +FranklinWH Energy Storage Inc: aPower Syyy {240V},240,50.3548,9776.44,10016.4,400,-1.24751e-06,-2.30347e-05,-0.00028336,-0.000225482,59.3,480.0,25.041,250.0,480.0,NaN,Y +Fronius International GmbH: Fronius Primo 100-1 208-240 {208V},208,36.2304,9995,10292.2,660,-4.27565e-07,-2.93098e-05,-0.000757629,-0.00278479,0.24,800.0,15.5942,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 100-1 208-240 {240V},240,44.2769,9995,10296,655,-7.99734e-07,-2.80816e-05,-0.000619957,0.000286398,0.32,800.0,15.7191,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 114-1 208-240 {208V},208,36.8573,11400,11743.9,660,-4.71735e-07,-3.22588e-05,-0.000729455,-0.00177511,0.24,800.0,17.7938,240.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 114-1 208-240 {240V},240,49.1389,11400,11738.7,660,-6.6823e-07,-3.28235e-05,-0.000723615,-0.000765126,0.32,800.0,17.7859,240.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 125-1 208-240 {208V},208,43.2976,12500,12891.6,665,-6.70862e-07,-3.29869e-05,-0.00141094,-0.00233539,0.24,800.0,19.3858,260.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 125-1 208-240 {240V},240,45.21,12500,12866.7,660,-3.92513e-07,-3.58729e-05,-0.00148254,-0.00376868,0.32,800.0,19.495,260.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 150-1 208-240 {208V},208,41.5046,13750,14180.4,680,-7.05383e-07,-2.64258e-05,-0.00128825,-0.00127064,0.24,800.0,20.8535,320.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 150-1 208-240 {240V},240,55.7458,15000,15456.2,680,-7.60012e-07,-2.76211e-05,-0.000709219,-0.000288637,0.32,800.0,22.7297,320.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 38-1 208-240 {208V},208,48.3722,3800,3910.19,650,-3.71891e-06,-2.66928e-05,0.000173807,0.000383712,0.41,800.0,6.01567,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 38-1 208-240 {240V},240,53.2488,3800,3911.35,650,-3.1445e-06,-2.96187e-05,-4.79811e-05,0.000276228,0.55,800.0,6.01747,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 50-1 208-240 {208V},208,46.4406,5000,5139.9,650,-2.52356e-06,-2.31681e-05,2.79511e-05,-3.9618e-05,0.41,800.0,7.90755,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 50-1 208-240 {240V},240,40.4138,5000,5130.29,660,-2.12156e-06,-2.76119e-05,-0.000426916,0.000107843,0.55,800.0,7.77316,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 60-1 208-240 {208V},208,43.5807,6000,6168.1,660,-1.93124e-06,-2.46231e-05,-6.36271e-05,-0.000382035,0.41,800.0,9.34561,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 60-1 208-240 {240V},240,50.0694,6000,6164.9,660,-1.90852e-06,-2.48935e-05,-0.000198599,-0.000136111,0.55,800.0,9.34076,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 76-1 208-240 {208V},208,31.0939,7600,7813,660,-1.56948e-06,-2.61785e-05,-0.000585176,-0.000648155,0.41,800.0,11.8379,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 76-1 208-240 {240V},240,38.7693,7600,7802.58,660,-1.47915e-06,-2.79652e-05,-0.000607413,-0.000576395,0.55,800.0,11.8221,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 82-1 208-240 {208V},208,36.5065,7900,8122.26,660,-1.8366e-06,-2.43036e-05,-0.00021285,-0.000189682,0.41,800.0,12.3064,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Primo 82-1 208-240 {240V},240,37.9417,8200,8417.25,660,-1.23505e-06,-2.48471e-05,-0.000605738,-0.000454246,0.55,800.0,12.7534,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 100-3 208-240 {208V},208,31.868,9995,10341.3,370,-1.04367e-06,-2.21957e-05,-0.000357683,-0.000230614,0.81,480.0,27.9494,100.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 100-3 208-240 {240V},240,31.868,9995,10341.3,370,-1.04367e-06,-2.21957e-05,-0.000357683,-0.000230614,0.8,480.0,27.9494,100.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 100-3 480 {480V},480,64.1251,9995,10260.1,670,-2.75409e-07,-2.25745e-05,-0.000385046,0.00168874,0.86,800.0,15.3135,100.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 120-3 208-240 {208V},208,24.779,12000,12525.2,350,-1.37163e-06,-2.4454e-05,0.00280863,-0.00147969,0.61,480.0,35.7863,300.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 120-3 208-240 {240V},240,32.6128,12000,12455.2,370,-1.04111e-06,-4.04651e-05,-0.000971043,-0.00175859,0.81,480.0,33.6628,300.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 125-3 480 {480V},480,45.951,12500,12811.7,685,-3.14852e-07,-3.33992e-05,-0.000974036,0.00240631,0.94,800.0,18.7032,350.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 150-3 208 {208V},208,38.2588,15000,15578.8,445,-8.46195e-07,2.99741e-05,0.00227596,0.000423236,0.43,800.0,35.0086,325.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 150-3 480 {480V},480,76.5365,15000,15389.6,685,-4.63186e-07,-3.31484e-05,-0.000815642,-0.000778404,1.03,800.0,22.4666,350.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 175-3 480 {480V},480,65.6762,17500,17899.4,700,-2.70457e-07,-3.37599e-05,-0.00113653,0.000314369,1.03,800.0,25.5706,400.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 200-3 480 {480V},480,62.4723,20000,20467.5,712,-2.30167e-07,-3.35705e-05,-0.0015626,-0.00134756,1.04,800.0,28.7464,450.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 227-3 480 {480V},480,62.3069,22730,23259.6,720,-2.62785e-07,-3.54862e-05,-0.00189122,-0.0022622,1.03,800.0,32.305,500.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo 240-3 480 {480V},480,72.7439,24000,24573.5,725,-3.08728e-07,-2.83264e-05,-0.00112295,0.000545617,1.03,800.0,33.8945,500.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 100-3 208-240 Lite {208V},208,27.4052,10011,10423.2,355,-1.28814e-06,-1.58186e-05,-0.00109171,-0.00306737,0.6,480.0,29.3612,300.0,480.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 100-3 208-240 Lite {240V},240,31.8956,10062,10424.5,370,-9.77457e-07,-3.48658e-05,-0.000536327,-0.000962468,0.8,480.0,28.1745,300.0,480.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 100-3 208-240 {208V},208,27.4052,10011,10423.2,355,-1.28814e-06,-1.58186e-05,-0.00109171,-0.00306737,0.6,480.0,29.3612,300.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 100-3 208-240 {240V},240,31.8956,10062,10424.5,370,-9.77457e-07,-3.48658e-05,-0.000536327,-0.000962468,0.8,480.0,28.1745,300.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 120-3 208-240 Lite {208V},208,26.0129,12341,12882.4,350,-1.34731e-06,-2.45296e-05,0.00283681,-0.00123787,0.61,480.0,36.8069,300.0,480.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 120-3 208-240 Lite {240V},240,32.1665,12090,12546.9,370,-9.88265e-07,-3.90169e-05,-0.00106095,-0.00167393,0.8,480.0,33.9106,300.0,480.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 120-3 208-240 {208V},208,26.0129,12341,12882.4,350,-1.34731e-06,-2.45296e-05,0.00283681,-0.00123787,0.61,480.0,36.8069,300.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 120-3 208-240 {240V},240,32.1665,12090,12546.9,370,-9.88265e-07,-3.90169e-05,-0.00106095,-0.00167393,0.8,480.0,33.9106,300.0,480.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 150-3 480 Lite {480V},480,76.3954,15197,15590.2,685,-4.29634e-07,-3.37745e-05,-0.0008768,-0.00130111,1.0,800.0,22.7594,350.0,800.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 150-3 480 {480V},480,76.3954,15197,15590.2,685,-4.29634e-07,-3.37745e-05,-0.0008768,-0.00130111,1.0,800.0,22.7594,350.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 200-3 480 Lite {480V},480,85.7186,20227,20704.6,710,-2.7877e-07,-3.25304e-05,-0.000787704,-0.000800655,1.0,800.0,29.1614,450.0,800.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 200-3 480 {480V},480,85.7186,20227,20704.6,710,-2.7877e-07,-3.25304e-05,-0.000787704,-0.000800655,1.0,800.0,29.1614,450.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 227-3 480 Lite {480V},480,61.851,22876,23407.4,722,-2.51258e-07,-3.36412e-05,-0.00164467,-0.000974706,1.0,800.0,32.4202,500.0,800.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 227-3 480 {480V},480,61.851,22876,23407.4,722,-2.51258e-07,-3.36412e-05,-0.00164467,-0.000974706,1.0,800.0,32.4202,500.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Fronius Symo Advanced 240-3 480 Lite {480V},480,70.708,24142,24717.7,722,-2.79205e-07,-3.08341e-05,-0.00104839,0.0004112,1.0,800.0,34.235,500.0,800.0,NaN,N +Fronius International GmbH: Fronius Symo Advanced 240-3 480 {480V},480,70.708,24142,24717.7,722,-2.79205e-07,-3.08341e-05,-0.00104839,0.0004112,1.0,800.0,34.235,500.0,800.0,2019-03-01 00:00:00,N +Fronius International GmbH: Primo GEN24 100 208-240 Plus {208V},208,33.2463,9454,9806.16,365,-1.68195e-06,-7.29372e-06,0.000751993,-0.000591233,8.4,480.0,26.8662,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 100 208-240 Plus {240V},240,33.7727,10019,10341,385,-1.30873e-06,-1.31234e-05,0.00116002,-0.000487274,8.5,480.0,26.8597,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 100 208-240 {208V},208,33.2463,9454,9806.16,365,-1.68195e-06,-7.29372e-06,0.000751993,-0.000591233,8.4,480.0,26.8662,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 100 208-240 {240V},240,33.7727,10019,10341,385,-1.30873e-06,-1.31234e-05,0.00116002,-0.000487274,8.5,480.0,26.8597,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 38 208-240 Plus {208V},208,26.9563,3805,3922.65,360,-3.04044e-06,-2.32229e-05,-0.00118809,-0.00104246,8.4,480.0,10.8962,200.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 38 208-240 Plus {240V},240,27.8054,3802,3904.29,400,-2.42889e-06,-3.3482e-05,-0.0016737,-0.000169443,8.3,480.0,9.76072,200.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 38 208-240 {208V},208,26.9563,3805,3922.65,360,-3.04044e-06,-2.32229e-05,-0.00118809,-0.00104246,8.4,480.0,10.8962,200.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 38 208-240 {240V},240,27.8054,3802,3904.29,400,-2.42889e-06,-3.3482e-05,-0.0016737,-0.000169443,8.3,480.0,9.76072,200.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 50 208-240 Plus {208V},208,25.7865,5006,5161.5,360,-2.4166e-06,-1.29551e-05,-0.000944013,-0.000193859,8.2,480.0,14.3375,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 50 208-240 Plus {240V},240,26.5051,5007,5142.92,400,-1.80914e-06,-2.54848e-05,-0.00146911,0.00115105,8.3,480.0,12.8573,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 50 208-240 {208V},208,25.7865,5006,5161.5,360,-2.4166e-06,-1.29551e-05,-0.000944013,-0.000193859,8.2,480.0,14.3375,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 50 208-240 {240V},240,26.5051,5007,5142.92,400,-1.80914e-06,-2.54848e-05,-0.00146911,0.00115105,8.3,480.0,12.8573,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 60 208-240 Plus {208V},208,24.9122,5743,5933.06,360,-2.32115e-06,-1.40795e-05,-0.000659896,0.000222092,8.4,480.0,16.4807,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 60 208-240 Plus {240V},240,26.1868,6004,6172.99,400,-1.73503e-06,-2.43617e-05,-0.00165453,0.000298699,8.3,480.0,15.4325,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 60 208-240 {208V},208,24.9122,5743,5933.06,360,-2.32115e-06,-1.40795e-05,-0.000659896,0.000222092,8.4,480.0,16.4807,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 60 208-240 {240V},240,26.1868,6004,6172.99,400,-1.73503e-06,-2.43617e-05,-0.00165453,0.000298699,8.3,480.0,15.4325,230.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 77 208-240 Plus {208V},208,34.2219,7689,7957.3,365,-1.72075e-06,-4.35358e-06,0.00103579,-0.000266698,9.2,480.0,21.8008,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 77 208-240 Plus {240V},240,36.1704,7686,7916.9,385,-1.51715e-06,-9.58435e-06,0.000926174,-0.000785161,9.2,480.0,20.5634,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 77 208-240 {208V},208,34.2219,7689,7957.3,365,-1.72075e-06,-4.35358e-06,0.00103579,-0.000266698,9.2,480.0,21.8008,260.0,480.0,2025-05-01 00:00:00,Y +Fronius International GmbH: Primo GEN24 77 208-240 {240V},240,36.1704,7686,7916.9,385,-1.51715e-06,-9.58435e-06,0.000926174,-0.000785161,9.2,480.0,20.5634,260.0,480.0,2025-05-01 00:00:00,Y +GE Renewable Energy: RIU-2500-U {550V},550,8485.63,2507194,2.57916e+06,975,-7.05627e-09,5.56504e-06,0.000106673,-0.000143943,62.8,1500.0,2645.3,800.0,1500.0,2021-03-01 00:00:00,Y +Gamesa Electric: PV3800 {600V},600,9564.13,3418394,3.50482e+06,1050,-5.91971e-09,1.3955e-05,0.00144068,0.000563824,267.0,1300.0,3337.93,835.0,1300.0,NaN,N +Gamesa Electric: PV4000 {630V},630,9666.48,3597332,3.68508e+06,1050,-5.32488e-09,1.40284e-05,0.00133538,0.000741187,267.0,1300.0,3509.6,875.0,1300.0,NaN,N +Gamesa Electric: PV4100 {600V},600,7718.26,4054978,4.12336e+06,1050,-3.77169e-09,1.3161e-05,0.00246178,0.000965468,267.0,1300.0,3927.01,835.0,1300.0,2021-12-01 00:00:00,N +Gamesa Electric: PV4200 {660V},660,10050,3767352,3.85301e+06,1050,-5.30073e-09,1.33502e-05,0.00114196,0.000324065,267.0,1300.0,3669.53,915.0,1300.0,NaN,N +Gamesa Electric: PV4300 {630V},630,11446.8,4260428,4.36519e+06,1050,-5.01136e-09,1.45423e-05,0.00165101,0.000801021,267.0,1300.0,4157.32,875.0,1300.0,2021-12-01 00:00:00,N +Gamesa Electric: PV4400 {690V},690,10244,3939574,4.03022e+06,1050,-4.29355e-09,2.1143e-05,0.00136835,0.000868953,267.0,1300.0,3838.3,955.0,1300.0,NaN,N +Gamesa Electric: PV4500 {660V},660,11031.2,4405964,4.50858e+06,1050,-4.51418e-09,1.47038e-05,0.00155308,0.00080257,267.0,1300.0,4293.88,915.0,1300.0,2021-12-01 00:00:00,N +Gamesa Electric: PV4700 {690V},690,11125.5,4654418,4.75894e+06,1050,-4.12767e-09,1.44204e-05,0.00194336,0.00102789,267.0,1300.0,4532.32,955.0,1300.0,2021-12-01 00:00:00,N +Generac Power Systems Inc: APKE00075 {240V},240,25.2074,11472.8,11715.6,400,-1.25997e-06,5.21049e-06,0.00335327,-0.00128873,77.44,420.0,29.2891,360.0,420.0,NaN,N +Generac Power Systems Inc: CP-380-V2 {208V},208,3.81791,380,392.804,34,-5.19083e-05,-0.000119448,0.0438348,-0.000659345,0.14,36.0,11.5531,32.0,36.0,2024-11-01 00:00:00,N +Generac Power Systems Inc: CP-380-V2 {240V},240,3.86807,380,392.114,34,-4.76017e-05,-0.000170544,0.0544607,0.000767702,0.19,36.0,11.5328,32.0,36.0,2024-11-01 00:00:00,N +Generac Power Systems Inc: CP-760-V2 {208V},208,4.47468,762,790.123,68,-2.98545e-05,-0.000219548,0.0230919,-0.0132839,0.14,72.0,11.6195,63.0,72.0,2024-11-01 00:00:00,N +Generac Power Systems Inc: CP-760-V2 {240V},240,4.58846,761,786.208,68,-2.63126e-05,-0.000198918,0.0227021,-0.0125358,0.19,72.0,11.5619,63.0,72.0,2024-11-01 00:00:00,N +Generac Power Systems Inc: PM-820 {208V},208,6.36559,820,848.812,37.5,-2.97385e-05,-0.000419359,0.048973,-0.0158297,0.35,40.0,22.635,31.5,40.0,NaN,N +Generac Power Systems Inc: PM-820 {240V},240,6.03302,820,846.725,37.5,-2.63752e-05,-0.000535419,0.0453158,-0.0286893,0.39,40.0,22.5793,31.5,40.0,NaN,N +Generac Power Systems Inc: X11402 {208V},208,20.9471,11180,11528,400,-1.26292e-06,6.51691e-05,0.0104516,-0.00271344,0.125,420.0,28.82,390.0,420.0,2021-04-01 00:00:00,Y +Generac Power Systems Inc: X7602 {240V},240,66.92,7586,7822.22,400,-2.67644e-06,4.6708e-05,0.00321561,-0.00397886,1.2917,420.0,19.5555,390.0,420.0,2021-04-01 00:00:00,Y +Generac Power Systems Inc: XVT076A03 {240V},240,38.8116,7606,7906.96,400,-2.75739e-06,2.99256e-05,0.00603482,0.000831369,41.9,420.0,19.7674,390.0,420.0,2023-08-11 00:00:00,Y +Generac Power Systems Inc: XVT114G03 {208V},208,60.7634,11748,12087.7,400,-9.37366e-07,7.86436e-05,0.0114327,0.00799753,0.13,420.0,30.2193,390.0,420.0,2021-04-01 00:00:00,Y +General Motors Energy LLC: GM Energy Inverter e111 {208V},208,39.8095,10056.8,10400.4,380,-2.26455e-06,-3.68162e-05,-0.000609407,-0.000734532,16.23,480.0,27.3696,200.0,480.0,NaN,Y +General Motors Energy LLC: GM Energy Inverter e111 {240V},240,38.4173,11588.6,11947.8,380,-1.70407e-06,-4.99163e-05,-0.0019333,-0.0023664,16.48,480.0,31.4415,200.0,480.0,NaN,Y +Geneverse Energy Inc: GVI-HS-10K-USM {240V},240,51.9471,10176.7,10475.4,360,-1.26046e-06,-2.00266e-05,-4.72702e-05,-0.000721728,33.64,430.0,29.0984,280.0,430.0,NaN,Y +Geneverse Energy Inc: GVI-HS-5K-USM {240V},240,29.3587,5089.67,5247.54,360,-3.6512e-06,-1.51201e-05,0.000125821,0.000551915,22.6,430.0,14.5765,180.0,430.0,NaN,Y +Geneverse Energy Inc: GVI-HS-6K-USM {240V},240,33.6679,6117.18,6297.92,360,-2.58712e-06,-2.03094e-05,0.000191477,-0.0002564,22.99,430.0,17.4942,200.0,430.0,NaN,Y +Geneverse Energy Inc: GVI-HS-7K6-USM {240V},240,37.4864,7764.72,7993.03,360,-1.60481e-06,-2.20797e-05,-0.000935129,-0.00139184,30.71,430.0,22.2029,220.0,430.0,NaN,Y +Geneverse Energy Inc: GVI-HS-8K-USM {240V},240,65.6455,8084.16,8326.86,360,-2.93482e-06,-6.00331e-06,-0.000923485,-0.00173197,17.4,430.0,23.1302,250.0,430.0,NaN,Y +Ginlong Technologies Co Ltd: RHI-1P10K-HVES-5G {240V},240,46.9903,10005,10278.7,330,-1.64372e-06,-2.82201e-05,-0.00142156,-0.00302157,1.0,450.0,31.1477,230.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: RHI-1P5K-HVES-5G {240V},240,22.5654,5003,5145.75,330,-3.4929e-06,-3.04962e-05,-0.000780736,-0.00192375,1.0,450.0,15.5932,115.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: RHI-1P6K-HVES-5G {240V},240,18.1299,6004,6162.89,330,-9.94064e-07,-3.60978e-05,-0.00396189,-0.0132426,1.0,450.0,18.6754,130.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: RHI-1P76K-HVES-5G {240V},240,26.512,7603,7804.09,330,-1.22394e-06,-4.29761e-05,-0.00161919,-0.00582153,1.0,450.0,23.6488,175.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: RHI-1P7K-HVES-5G {240V},240,29.8882,7006,7212.25,330,-2.33014e-06,-3.39293e-05,-0.00252549,-0.0042176,1.0,450.0,21.8553,160.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: RHI-1P8K-HVES-5G {240V},240,36.7315,8006,8239.62,330,-2.26877e-06,-4.02283e-05,-0.000978748,-0.0025584,1.0,450.0,24.9686,185.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: RHI-1P9K-HVES-5G {240V},240,37.3803,9006,9256.11,330,-1.71093e-06,-2.94147e-05,-0.000639124,-0.00201434,1.0,450.0,28.0488,210.0,450.0,2020-10-01 00:00:00,Y +Ginlong Technologies Co Ltd: S5-GC100K-US {480V},480,83.3344,99368,101480,730,-9.89649e-08,-2.16309e-05,-0.00421283,-0.000696959,2.0,850.0,139.013,550.0,850.0,2023-05-11 00:00:00,N +Ginlong Technologies Co Ltd: S5-GC125K-US {480V},480,238.263,124991,127695,770,-9.39524e-08,2.03171e-05,0.0015464,0.00185076,3.36,850.0,165.837,550.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S5-GC60K-LV-US {208V},208,77.1698,59996,61203.3,470,-1.35458e-07,2.86737e-05,0.00294854,0.00178865,3.12,650.0,130.22,400.0,650.0,NaN,N +Ginlong Technologies Co Ltd: S5-GC60K-LV-US {240V},240,70.0916,59996,61192.8,470,-1.25404e-07,2.89294e-05,0.00355532,0.00215258,3.12,650.0,130.198,400.0,650.0,NaN,N +Ginlong Technologies Co Ltd: S5-GC75K-US {480V},480,100.985,74574,75961.2,730,-1.00225e-07,-1.8402e-05,-0.00194831,-0.00193715,2.0,850.0,104.056,550.0,850.0,2023-05-11 00:00:00,N +Ginlong Technologies Co Ltd: S5-GC80K-US {480V},480,85.2043,79446,80980.1,730,-1.06763e-07,-1.91641e-05,-0.00190658,-0.000627037,2.0,850.0,110.932,550.0,850.0,2023-05-11 00:00:00,N +Ginlong Technologies Co Ltd: S5-GC90K-US {480V},480,83.3011,89449,91284.7,730,-1.1002e-07,-2.01152e-05,-0.00246781,-0.000565624,2.0,850.0,125.048,550.0,850.0,2023-05-11 00:00:00,N +Ginlong Technologies Co Ltd: S6-EH1P10K-H-US {240V},240,54.8578,10001,10269.2,380,-8.48587e-07,-1.4818e-05,0.000177184,-0.00413525,16.38,450.0,27.0242,230.0,450.0,2025-06-11 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH1P114K-H-US {240V},240,19.6249,11406,11710.4,380,1.64665e-07,-1.31236e-05,-0.00857451,0.0382415,15.36,450.0,30.8169,245.0,450.0,2025-06-11 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH1P38K-H-US {240V},240,5.56215,3800.98,3928.05,370,3.59337e-07,-7.97999e-07,0.00313296,-0.00561461,18.83,450.0,10.6163,140.0,450.0,2025-06-11 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH1P5K-H-US {240V},240,12.5954,5001.66,5166.34,370,-1.69125e-07,-3.44038e-06,-0.00257647,-0.0284763,18.83,450.0,13.9631,140.0,450.0,2025-06-11 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH1P76K-H-US {240V},240,19.7473,7604,7805.91,380,9.18811e-08,-2.69402e-06,0.0015204,0.00471397,16.33,450.0,20.5419,175.0,450.0,2025-06-11 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH1P99K-H-US {240V},240,54.8061,9990,10257.9,380,-8.49637e-07,-1.48176e-05,0.000177231,-0.00413471,16.38,450.0,26.9945,230.0,450.0,2025-06-11 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P114K03-SV-YD-L-US {240V},240,53.3396,11410,11947.3,380,-1.12376e-06,1.1544e-06,-0.00134023,-0.000731153,26.79,450.0,31.4403,160.0,450.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P12K03-SV-YD-L-US {240V},240,55.9002,11940,12501.8,380,-1.07004e-06,7.62623e-07,-0.00224239,-0.00141122,27.02,450.0,32.8995,160.0,450.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P12K03-SV-YD-L-US-E {240V},240,54.9245,11939,12500.4,380,-1.00879e-06,1.79022e-06,-0.000301612,0.00025387,26.72,450.0,32.8958,160.0,450.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P14K03-SV-YD-L-US {240V},240,66.4495,13960,14614.3,380,-9.35036e-07,1.57512e-06,-0.00186124,-0.000773309,26.98,450.0,38.4588,186.0,450.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P16K03-SV-YD-L-US {240V},240,54.7951,15911,16665.7,380,-6.74909e-07,1.09642e-06,-0.00396721,-0.00188525,27.07,450.0,43.8572,186.0,450.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P16K03-SV-YD-L-US-E {240V},240,80.0109,15940,16687,380,-8.34922e-07,1.06802e-06,-0.00132394,-0.000878798,23.07,450.0,43.9132,186.0,450.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH2P96K03-SV-YD-L-US {240V},240,50.8687,9647.1,10100.9,370,-1.43636e-06,-3.0652e-06,0.00106873,0.000458732,27.1,425.0,27.2996,240.0,425.0,2026-03-23 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US {208V},208,66.6574,25900,26668.2,605,-4.45123e-07,-1.42853e-05,-0.000269496,-0.00143198,58.0,850.0,44.0797,360.0,850.0,2025-11-12 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US {240V},240,76.1535,29705,30584.9,605,-4.0404e-07,-1.47887e-05,0.000225437,-0.000992717,61.0,850.0,50.5536,360.0,850.0,2025-11-12 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {208V},208,151.045,25883.5,26603.9,675,-1.9297e-07,-4.88468e-06,0.00319636,0.00408515,57.3,850.0,39.4131,500.0,850.0,NaN,Y +Ginlong Technologies Co Ltd: S6-EH3P30K03-LV-YD-H-US(21A) {240V},240,166.661,29834.2,30631.4,675,-1.61777e-07,-8.69442e-06,0.00305494,0.0103769,70.7,850.0,45.3798,500.0,850.0,NaN,Y +Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US {480V},480,81.6669,29891,30769.3,605,-3.91604e-07,-1.48942e-05,-0.000286731,-0.00170014,56.0,850.0,50.8583,360.0,850.0,2025-11-12 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P30K03-NV-YD-H-US(21A) {480V},480,181.699,29884.7,30671.3,675,-2.56628e-07,-8.95856e-06,0.00233231,0.00394592,54.5,850.0,45.439,500.0,850.0,NaN,Y +Ginlong Technologies Co Ltd: S6-EH3P40K04-NV-YD-H-US {480V},480,97.4738,39802.9,40961.2,605,-2.57076e-07,-1.52694e-05,-0.000301246,-0.00181528,57.0,850.0,67.7045,360.0,850.0,2025-11-12 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P40K04-NV-YD-H-US(21A) {480V},480,169.229,39844,40916,675,-2.13109e-07,2.29322e-06,0.000528771,0.00314214,70.0,850.0,60.6163,500.0,850.0,NaN,Y +Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US {480V},480,128.021,49800.3,51265.9,650,-2.26334e-07,-1.94768e-05,-0.000539627,-0.0022335,52.0,850.0,78.8707,450.0,850.0,2025-11-12 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P50K04-NV-YD-H-US(21A) {480V},480,208.565,49803.4,51129,725,-2.06513e-07,-1.13139e-05,-0.00135628,-0.00228895,76.0,850.0,70.5228,600.0,850.0,NaN,Y +Ginlong Technologies Co Ltd: S6-EH3P60K04-NV-YD-H-US {480V},480,158.349,59709.8,61481.1,650,-2.01522e-07,-1.71716e-05,-9.26989e-05,-0.00137001,59.0,850.0,94.5864,450.0,850.0,2025-11-12 00:00:00,Y +Ginlong Technologies Co Ltd: S6-EH3P60K04-NV-YD-H-US(21A) {480V},480,166.871,59763,61409.5,725,-1.74792e-07,-4.53084e-06,0.000604975,-7.43048e-05,76.0,850.0,84.7028,600.0,850.0,NaN,Y +Ginlong Technologies Co Ltd: S6-GC25K-US {480V},480,15.3191,24887.6,25299.2,720,-1.96133e-07,-2.23478e-06,-0.00265327,-0.00269342,3.2724,850.0,35.1377,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC30K-LV-US {208V},208,84.9098,29878,31000.4,580,-7.9747e-07,3.01359e-06,0.000167207,-0.000164951,1.394,680.0,53.449,340.0,680.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC30K-LV-US {240V},240,85.0006,29877.6,30998.5,580,-7.98538e-07,2.86698e-06,0.000135074,-0.000188354,1.394,680.0,53.4457,340.0,680.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC30K-US {480V},480,36.132,29883,30405,720,-2.67085e-07,-2.82587e-06,-0.000846519,-0.000952389,3.2724,850.0,42.2291,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC33K-US {480V},480,23.6289,32865,33414.1,720,-1.84907e-07,-9.43334e-07,0.000577347,0.000401846,3.2724,850.0,46.4084,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC36K-US {480V},480,38.3233,35866,36520.8,720,-2.71062e-07,1.95129e-06,0.000864189,0.000780439,3.2724,850.0,50.7234,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC40K-US {480V},480,107.802,39841,40644.3,720,-4.54891e-07,1.07183e-05,0.000306405,0.00129958,3.2724,850.0,56.4504,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC50K-US {480V},480,104.275,49848,50714.8,720,-2.255e-07,-6.55568e-06,0.000373405,-0.00106045,3.2724,850.0,70.4372,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GC60K-US {480V},480,121.037,59898,60956.2,720,-1.91613e-07,-1.90255e-06,0.000811883,8.54779e-05,3.1623,850.0,84.6614,580.0,850.0,NaN,N +Ginlong Technologies Co Ltd: S6-GU250K-EHV-US-M12 {600V},600,889.752,248751,252221,1080,-2.89319e-08,-8.61539e-07,0.000197717,0.000246099,15.36,1300.0,233.538,860.0,1300.0,NaN,N +Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V},800,1088.94,348153,353576,1080,-3.16193e-08,-5.8444e-07,0.000326469,0.000365731,15.36,1300.0,327.385,860.0,1300.0,NaN,N +Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V},800,1036.7,348488,353908,1080,-3.07211e-08,-6.33019e-07,0.000678298,0.000556735,15.36,1300.0,327.692,860.0,1300.0,NaN,N +Ginlong Technologies Co Ltd: Solis-100K-5G-US {480V},480,117.287,100000,101782,720,-9.94018e-08,-2.91638e-06,0.000305908,0.00061374,1.0,850.0,141.364,550.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-100K-EHV-5G {600V},600,50.2638,100000,101429,950,-5.89054e-08,1.07834e-05,0.00234758,0.00124485,1.0,1250.0,106.767,860.0,1250.0,2020-10-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-125K-EHV-5G {600V},600,40.5821,125000,126734,950,-3.53178e-08,1.1619e-05,0.00466754,0.00303841,1.0,1250.0,133.404,860.0,1250.0,2020-10-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-125K-EHV-5G-US-PLUS {600V},600,213.642,136724,139389,1180,-8.63968e-08,-8.84266e-06,-0.00163966,-0.00161096,2.0,1300.0,118.126,860.0,1300.0,NaN,N +Ginlong Technologies Co Ltd: Solis-125K1-EHV-5G {600V},600,145.212,125083,127176,1080,-7.90126e-08,-2.40218e-06,0.000251427,0.000453422,1.0,1250.0,117.756,860.0,1250.0,NaN,N +Ginlong Technologies Co Ltd: Solis-185K-EHV-5G-US {600V},600,328.673,185005,188214,1080,-5.97009e-08,-4.53711e-06,0.00108483,0.000387473,1.0,1300.0,174.273,850.0,1300.0,NaN,N +Ginlong Technologies Co Ltd: Solis-185K-EHV-5G-US-PLUS {600V},600,227.296,172987,176392,1180,-6.47762e-08,-1.00381e-05,-0.000183716,-0.000747501,2.0,1300.0,149.485,860.0,1300.0,2023-01-23 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P10K-4G-US {240V},240,45.5782,10000,10270.6,380,-1.56647e-06,-2.22991e-05,-0.00093326,-0.00207585,7.0,500.0,27.0279,250.0,500.0,2023-02-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P25K-4G-US {240V},240,17.4198,2500,2581.94,330,-7.22125e-06,-8.7343e-06,0.000131515,0.000730919,3.2,500.0,7.82405,120.0,500.0,2020-09-11 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P36K-4G-US {240V},240,26.0679,3600,3719.48,330,-6.02653e-06,-7.4097e-06,-5.37917e-06,0.00069309,3.5,500.0,11.2712,180.0,500.0,2023-02-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P3K-4G-US {240V},240,22.2261,3000,3100.3,330,-7.25165e-06,-6.72144e-06,0.000209919,0.000754903,3.3,500.0,9.39486,140.0,500.0,2020-09-11 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P46K-4G-US {240V},240,34.4025,4600,4744.17,360,-4.14372e-06,-1.5333e-05,-0.000245649,0.000387855,3.6,500.0,13.1783,200.0,500.0,2020-09-11 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P4K-4G-US {240V},240,28.5494,4000,4130.84,330,-5.40054e-06,-1.03044e-05,-2.08538e-05,0.000237151,3.5,500.0,12.5177,190.0,500.0,2020-09-11 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P5K-4G-US {240V},240,37.5009,5000,5156.41,360,-4.02338e-06,-1.16955e-05,-5.06863e-05,-0.000186678,3.6,500.0,14.3234,240.0,500.0,2023-02-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P6K-4G-US {240V},240,18.5656,6000,6159.99,380,-1.07428e-06,-3.80794e-05,-0.00406138,-0.0129017,6.0,500.0,16.2105,200.0,500.0,2023-02-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P6K2-4G-US {240V},240,45.5586,6000,6181.83,360,-3.42586e-06,-1.01268e-05,0.000108487,0.000172913,3.5,500.0,17.1718,300.0,500.0,2020-09-11 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P76K-4G-US {240V},240,26.2108,7600,7798.86,380,-1.18045e-06,-4.0288e-05,-0.00163795,-0.0058527,7.0,500.0,20.5233,200.0,500.0,2023-02-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P7K-4G-US {240V},240,30.8412,7000,7209.19,380,-2.45896e-06,-3.9607e-05,-0.00278918,-0.00466197,7.0,500.0,18.9716,250.0,500.0,2020-09-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P8K-4G-US {240V},240,37.0086,8000,8235.17,380,-2.30844e-06,-4.27295e-05,-0.00101495,-0.00268852,6.0,500.0,21.6715,250.0,500.0,2020-09-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-1P9K-4G-US {240V},240,37.3698,9000,9249.35,380,-1.71149e-06,-2.80554e-05,-0.00060075,-0.00187986,7.0,500.0,24.3404,250.0,500.0,2024-03-11 00:00:00,N +Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US {800V},800,394.759,255013,259309,1080,-3.6601e-08,-6.05916e-06,-0.000208903,-0.000323189,1.0,1300.0,240.101,850.0,1300.0,NaN,N +Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V},800,374.466,238706,242927,1180,-3.93097e-08,-3.05239e-05,-0.00263091,-0.000748698,2.0,1300.0,205.87,860.0,1300.0,2023-01-23 00:00:00,N +Ginlong Technologies Co Ltd: Solis-25K-US {480V},480,65.3352,25000,25581.9,650,-3.96177e-07,1.35059e-05,0.000622038,0.00289364,14.0,780.0,39.3568,580.0,780.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-25K-US-LSW {480V},480,28.9305,24958,25377.7,470,-2.44159e-07,-4.97673e-07,0.000519154,0.000650116,1.0,800.0,53.9951,347.0,800.0,NaN,N +Ginlong Technologies Co Ltd: Solis-25K-US-SW {480V},480,68.8259,25000,25568,650,-3.72917e-07,1.67241e-05,-0.000736454,0.0012912,14.0,770.0,39.3353,580.0,770.0,2020-08-21 00:00:00,N +Ginlong Technologies Co Ltd: Solis-30K-US {480V},480,41.2876,30000,30664.3,650,-2.61207e-07,1.27313e-06,0.00598325,0.00541474,15.0,780.0,47.1759,580.0,780.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-30K-US-LSW {480V},480,39.2007,29948,30453,700,-2.38831e-07,-1.1208e-06,0.000107757,0.000314952,1.0,800.0,43.5042,417.0,800.0,NaN,N +Ginlong Technologies Co Ltd: Solis-30K-US-SW {480V},480,52.9619,30000,30650.7,650,-2.97196e-07,4.62228e-06,0.00134634,0.00171057,15.0,780.0,47.155,580.0,780.0,2020-08-21 00:00:00,N +Ginlong Technologies Co Ltd: Solis-36K-US {480V},480,26.7656,36000,36714.2,650,-1.19224e-07,-4.75344e-06,0.00951705,0.00624775,15.0,780.0,56.4834,580.0,780.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-36K-US-F-SW {480V},480,44.6904,36000,36689.2,650,-1.62456e-07,2.91019e-06,0.00239541,0.00331556,15.0,780.0,56.4449,580.0,780.0,2020-08-21 00:00:00,N +Ginlong Technologies Co Ltd: Solis-36K-US-LSW {480V},480,55.7239,35925,36538.6,700,-2.2726e-07,-5.7441e-07,0.000333924,0.000618578,1.0,800.0,52.1979,500.0,800.0,NaN,N +Ginlong Technologies Co Ltd: Solis-36K-US-SW {480V},480,45.2456,36000,36692.4,650,-1.67703e-07,2.79933e-06,0.00244407,0.00328274,15.0,780.0,56.4498,580.0,780.0,2020-08-21 00:00:00,N +Ginlong Technologies Co Ltd: Solis-40K-US {480V},480,62.922,40000,40750.1,650,-1.90174e-07,-7.79676e-06,-0.000160631,-0.00072261,1.0,780.0,62.6925,580.0,780.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-40K-US-F {480V},480,78.3542,40000,40816.9,650,-2.85188e-07,-1.02547e-05,-3.04299e-05,-0.000796888,1.0,780.0,62.7952,580.0,780.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-40K-US-F-SW {480V},480,61.0596,40000,40735.5,650,-1.69944e-07,-8.69564e-06,0.000553295,-0.000145478,1.0,780.0,62.67,580.0,780.0,2020-08-21 00:00:00,N +Ginlong Technologies Co Ltd: Solis-40K-US-LSW {480V},480,58.3804,39926,40601.4,700,-1.85632e-07,-7.73373e-07,0.000603043,0.000910515,1.0,800.0,58.0021,556.0,800.0,NaN,N +Ginlong Technologies Co Ltd: Solis-40K-US-SW {480V},480,61.9905,40000,40735.5,650,-1.72763e-07,-8.61697e-06,0.000412271,-0.000364738,1.0,780.0,62.67,580.0,780.0,2020-08-21 00:00:00,N +Ginlong Technologies Co Ltd: Solis-50K-US {480V},480,42.454,50000,50777.9,650,-8.06193e-08,-2.39587e-06,0.00461059,0.0118958,1.0,720.0,78.1198,580.0,720.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-50K-US-F {480V},480,68.5998,50000,50815,650,-1.46383e-07,-7.67744e-06,0.000500706,0.00127503,1.0,720.0,78.1769,580.0,720.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-50K-US-F-LSW {480V},480,74.5542,49916,50766.4,720,-1.56866e-07,-5.33876e-07,0.000585649,0.000882891,1.0,850.0,70.5089,568.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-50K-US-F-SW {480V},480,68.875,50000,50815.3,650,-1.47078e-07,-8.10917e-06,0.000351798,0.00104103,1.0,720.0,78.1774,580.0,720.0,2020-09-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-50K-US-LSW {480V},480,73.9245,49984,50831,720,-1.52421e-07,-1.13082e-07,0.000834456,0.00123257,1.0,850.0,70.5985,568.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-50K-US-SW {480V},480,44.5102,50000,50786.7,650,-8.79096e-08,-5.21277e-06,0.00294909,0.00814369,1.0,720.0,78.1334,580.0,720.0,2020-09-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-60K-US-F {480V},480,87.0817,60000,61018.5,650,-1.32415e-07,-1.64425e-05,-0.000987295,-0.00153481,1.0,720.0,93.8747,580.0,720.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-60K-US-F-LSW {480V},480,88.6769,59933,60960.5,720,-1.34947e-07,-1.57113e-06,0.000349874,0.000407741,1.0,850.0,84.6674,526.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-60K-US-F-SW {480V},480,87.0111,60000,61017.8,650,-1.31794e-07,-1.62198e-05,-0.000918025,-0.00145187,1.0,720.0,93.8735,580.0,720.0,2020-09-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-66K-US-F {480V},480,95.5807,66000,67082.7,650,-1.14534e-07,-1.24509e-05,-0.000935208,-0.000264937,1.0,720.0,103.204,580.0,720.0,2019-11-15 00:00:00,N +Ginlong Technologies Co Ltd: Solis-66K-US-F-LSW {480V},480,103.177,65926,67057.4,720,-1.2482e-07,-5.83072e-07,0.000528093,0.000772483,1.0,850.0,93.1353,579.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-66K-US-F-SW {480V},480,95.4561,66000,67082.2,650,-1.1455e-07,-1.23648e-05,-0.00104525,-0.000304874,1.0,720.0,103.203,580.0,720.0,2020-09-01 00:00:00,N +Ginlong Technologies Co Ltd: Solis-75K-5G-US {480V},480,87.1138,75000,76332.4,720,-1.31519e-07,-2.94922e-06,0.000373221,0.000626437,1.0,850.0,106.017,550.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-80K-5G-US {480V},480,93.7255,80000,81422.3,720,-1.24267e-07,-2.95835e-06,0.000358831,0.000629308,1.0,850.0,113.086,550.0,850.0,NaN,N +Ginlong Technologies Co Ltd: Solis-90K-5G-US {480V},480,105.665,90000,91602.8,720,-1.10257e-07,-2.90948e-06,0.000304185,0.000610039,1.0,850.0,127.226,550.0,850.0,NaN,N +Global Tech China Ltd: SSM-114-SPHYB-UL {208V},208,54.1835,10186,10547.9,360,-1.72215e-06,-1.93048e-05,-0.00088788,-0.000792329,16.67,480.0,29.2997,200.0,480.0,NaN,Y +Global Tech China Ltd: SSM-114-SPHYB-UL {240V},240,53.7431,10140,10509.1,360,-1.67692e-06,-1.92664e-05,-0.00105436,-0.000924001,16.94,480.0,29.192,200.0,480.0,NaN,Y +Global Tech China Ltd: SSM-60-SPHYB-UL {208V},208,38.7377,6124,6337.4,360,-2.21552e-06,-3.10394e-05,-0.000949062,-0.000839798,19.2,480.0,17.6039,200.0,480.0,NaN,Y +Global Tech China Ltd: SSM-60-SPHYB-UL {240V},240,39.7427,6149,6334.31,360,-1.54617e-06,-3.52734e-05,-0.000457502,-0.000733113,19.2,480.0,17.5953,200.0,480.0,NaN,Y +Global Tech China Ltd: SSM-76-SPHYB-UL {208V},208,40.7154,7648,7919.76,360,-2.21533e-06,-1.97914e-05,-0.000689856,-0.000350054,15.0,480.0,21.9993,200.0,480.0,NaN,Y +Global Tech China Ltd: SSM-76-SPHYB-UL {240V},240,54.0097,7647.2,7922.96,360,-2.95854e-06,-1.59387e-05,-0.000322261,-6.73846e-05,15.0,480.0,22.0082,200.0,480.0,NaN,Y +Go Electric Inc: 250-480-60-HLT {480V},480,7101.25,259200,274787,700,-1.40173e-07,6.42573e-05,0.000805098,-0.00100803,748.7,780.0,392.552,540.0,780.0,2022-05-23 00:00:00,N +GoodWe Technologies Co Ltd: GEC114-1U-US20 {240V},240,39.3275,11391.9,11908.6,300,-1.56872e-06,-3.10692e-05,-0.00439272,-0.0056996,5.61,495.0,39.6954,235.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GEC50-1U-US10 {240V},240,31.6275,5031,5198.53,350,-2.1286e-06,-2.08949e-05,0.000437235,-0.000410676,11.16,495.0,14.8529,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GEC50-1U-US20 {240V},240,21.4902,4982.8,5201.83,300,-3.38565e-06,-5.11115e-05,-0.00207779,-0.00448311,5.6,495.0,17.3394,105.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GEC60-1U-US10 {240V},240,29.8727,6030,6241.04,350,-2.04722e-06,-2.37299e-05,-0.000156299,-0.00111257,11.3,495.0,17.8316,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GEC60-1U-US20 {240V},240,22.0414,6009.7,6273.96,300,-2.65546e-06,-4.88359e-05,-0.00427322,-0.00481943,5.6,495.0,20.9132,125.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GEC70-1U-US10 {240V},240,30.9599,7059,7315.56,350,-1.8714e-06,-2.23441e-05,0.00108225,-0.000404469,9.48,495.0,20.9016,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GEC76-1U-US10 {240V},240,29.9914,7648,7937.29,350,-1.80177e-06,-2.43109e-05,0.00102835,-0.000548669,9.48,495.0,22.678,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GEC76-1U-US20 {240V},240,30.8182,7585.5,7917.16,300,-2.03742e-06,-1.63256e-05,-0.00209605,-0.00328808,5.61,495.0,26.3905,158.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GEC86-1U-US10 {240V},240,27.7456,8680,9015.71,350,-1.62276e-06,-3.03918e-05,0.000685614,-0.00150842,9.47,495.0,25.7592,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GEC96-1U-US10 {240V},240,28.2373,9616,10008,350,-1.70726e-06,-3.60836e-05,0.000431581,-0.00185521,9.5,495.0,28.5943,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GEC96-1U-US20 {240V},240,39.6612,9603.1,10008.6,300,-1.56627e-06,-3.78155e-05,-0.00401472,-0.00696902,5.61,495.0,33.3619,200.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GEH114-1U-US20 {240V},240,27.6819,11379.3,11768.2,390,-1.32518e-06,1.45298e-05,-0.000465735,0.00281517,5.62,500.0,30.1748,270.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GEH50-1U-US10 {240V},240,22.5196,5067.5,5202.22,400,-2.09219e-06,-2.37074e-05,-0.000469767,-0.00031035,11.24,480.0,13.0055,300.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GEH50-1U-US20 {240V},240,20.3305,5004.7,5146.9,390,-2.17512e-06,-1.41151e-05,-0.00124995,-0.000962704,5.62,500.0,13.1972,235.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GEH60-1U-US10 {240V},240,20.7795,6109,6280.59,400,-1.98576e-06,-1.01674e-05,0.000203878,-0.000346084,9.3,480.0,15.7015,360.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GEH60-1U-US20 {240V},240,22.7117,5997.3,6171.43,390,-1.36512e-06,-2.20269e-05,0.000618264,0.00011739,5.62,500.0,15.8242,285.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GEH70-1U-US10 {240V},240,25.4624,7057,7267.2,400,-1.92279e-06,-4.89749e-05,0.000120641,-0.000138792,9.48,480.0,18.168,210.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GEH76-1U-US10 {240V},240,23.6388,7644,7879.28,400,-1.80292e-06,-4.54886e-05,3.02154e-06,-0.000274454,9.44,480.0,19.6982,230.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GEH76-1U-US20 {240V},240,25.3689,7588.2,7834.69,390,-2.09688e-06,-2.97007e-05,-0.00179294,-0.00199465,5.62,500.0,20.089,180.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GEH86-1U-US10 {240V},240,23.3258,8614,8891.7,400,-1.76225e-06,-3.6493e-05,2.6112e-05,-0.000109434,9.54,480.0,22.2292,260.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GEH96-1U-US10 {240V},240,22.5217,9628,9953.88,400,-1.7359e-06,-3.05626e-05,5.5607e-05,-0.000191057,9.4,480.0,24.8847,300.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GEH96-1U-US20 {240V},240,28.6476,9586.2,9912.27,390,-1.80565e-06,-1.28054e-05,-0.00126885,-0.000404749,5.62,500.0,25.4161,225.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GEP114-1-US30 {208V},208,35.973,9881.4,10303.2,330,-2.27738e-06,-2.56319e-05,-0.000980721,-0.00213286,4.5,500.0,31.2217,217.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP114-1-US30 {240V},240,50.46,11397,11809.1,380,-2.00568e-06,-3.9265e-05,-0.00283163,-0.00310892,4.5,500.0,31.0766,250.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP50-1-US30 {208V},208,23.7277,4339,4509.52,330,-2.99375e-06,-5.17679e-05,0.000292775,-0.00166949,4.5,500.0,13.6652,143.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP50-1-US30 {240V},240,29.5247,4968,5135.82,380,-2.5509e-06,-5.76085e-05,-0.00108943,-0.0029721,4.5,500.0,13.5153,165.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP60-1-US30 {208V},208,24.6262,5208,5416.85,330,-2.78802e-06,-3.95732e-05,5.72441e-05,-0.0014516,4.5,500.0,16.4147,171.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP60-1-US30 {240V},240,23.4254,5998,6204.09,380,-2.0735e-06,-5.06796e-05,-0.00088241,-0.0011094,4.5,500.0,16.3265,198.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP76-1-US30 {208V},208,25.5002,6589,6858.35,330,-2.87846e-06,-2.79961e-05,-0.00134097,-0.00168544,4.5,500.0,20.7829,217.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP76-1-US30 {240V},240,24.2736,7589,7864.43,380,-2.05941e-06,-4.11517e-05,-0.00119533,-0.000499875,4.5,500.0,20.6959,250.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP77-1-US30 {208V},208,10.3004,6630,6863.92,330,-1.48365e-06,-5.13242e-05,-0.00269961,-0.00196089,4.5,500.0,20.7998,150.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP77-1-US30 {240V},240,22.1448,7678,7913.17,380,-1.17414e-06,-4.99135e-05,-0.000168234,0.000369858,4.5,500.0,20.8241,170.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP96-1-US30 {208V},208,44.3245,8301,8644.45,330,-2.96225e-06,-3.65536e-05,-0.00116442,-0.00277616,4.5,500.0,26.1953,182.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GEP96-1-US30 {240V},240,38.8666,9566,9894.55,380,-1.97997e-06,-4.56388e-05,-0.00340117,-0.00393293,4.5,500.0,26.0383,210.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW11K4-ES-US20 {240V},240,27.6819,11379.3,11768.2,390,-1.32518e-06,1.45298e-05,-0.000465735,0.00281517,5.62,500.0,30.1748,270.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GW11K4-MS-US30 {208V},208,35.973,9881.4,10303.2,330,-2.27738e-06,-2.56319e-05,-0.000980721,-0.00213286,4.5,500.0,31.2217,217.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW11K4-MS-US30 {240V},240,50.46,11397,11809.1,380,-2.00568e-06,-3.9265e-05,-0.00283163,-0.00310892,4.5,500.0,31.0766,250.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW11K4-SBP-US20 {240V},240,39.3275,11391.9,11908.6,300,-1.56872e-06,-3.10692e-05,-0.00439272,-0.0056996,5.61,495.0,39.6954,235.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GW22KLV-SMT-US {208V},208,48.7491,22158.8,22981.9,450,-5.55047e-07,-1.07037e-05,-0.000758115,-0.00265862,4.47,750.0,51.0708,350.0,750.0,2025-10-13 00:00:00,N +GoodWe Technologies Co Ltd: GW22KLV-SMT-US {240V},240,62.9944,25002,25909.2,450,-4.89146e-07,1.38244e-06,-0.000218076,-0.00179465,3.08,750.0,57.576,350.0,750.0,2025-10-13 00:00:00,N +GoodWe Technologies Co Ltd: GW28KLV-SMT-US {208V},208,57.5329,28186.8,29106.3,450,-3.80552e-07,1.63203e-06,-0.000186127,-0.00187307,5.59,750.0,64.6807,350.0,750.0,2025-10-13 00:00:00,N +GoodWe Technologies Co Ltd: GW28KLV-SMT-US {240V},240,64.8793,32145.2,33274.8,450,-4.59221e-07,2.169e-06,-0.000568689,-0.00125871,5.23,750.0,73.9439,350.0,750.0,2025-10-13 00:00:00,N +GoodWe Technologies Co Ltd: GW5000-ES-US20 {240V},240,20.3305,5004.7,5146.9,390,-2.17512e-06,-1.41151e-05,-0.00124995,-0.000962704,5.62,500.0,13.1972,235.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GW5000-MS-US30 {208V},208,23.7277,4339,4509.52,330,-2.99375e-06,-5.17679e-05,0.000292775,-0.00166949,4.5,500.0,13.6652,143.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW5000-MS-US30 {240V},240,29.5247,4968,5135.82,380,-2.5509e-06,-5.76085e-05,-0.00108943,-0.0029721,4.5,500.0,13.5153,165.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW5000-SBP-US20 {240V},240,21.4902,4982.8,5201.83,300,-3.38565e-06,-5.11115e-05,-0.00207779,-0.00448311,5.6,495.0,17.3394,105.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GW5000A-BP {240V},240,31.6275,5031,5198.53,350,-2.1286e-06,-2.08949e-05,0.000437235,-0.000410676,11.16,495.0,14.8529,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GW5000A-ES {240V},240,22.5196,5067.5,5202.22,400,-2.09219e-06,-2.37074e-05,-0.000469767,-0.00031035,11.24,480.0,13.0055,300.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW5000A-MS {208V},208,21.7696,5133,5295.65,400,-2.53406e-06,-1.49245e-05,-0.000321417,-0.000431863,9.31,480.0,13.2391,300.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW5000A-MS {240V},240,22.5196,5067.5,5202.22,400,-2.09219e-06,-2.37074e-05,-0.000469767,-0.00031035,11.24,480.0,13.0055,300.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW5000H-ES {240V},240,62.6439,4989,5201.24,400,-3.80258e-06,-2.07039e-05,-0.000297805,-0.000631388,47.36,480.0,13.0031,300.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW50K-SMT-US {480V},480,136.879,51252,52156.9,720,-1.19514e-07,-1.88783e-05,-0.00113537,-0.000552078,7.14,850.0,72.4402,550.0,850.0,NaN,N +GoodWe Technologies Co Ltd: GW6000-ES-US20 {240V},240,22.7117,5997.3,6171.43,390,-1.36512e-06,-2.20269e-05,0.000618264,0.00011739,5.62,500.0,15.8242,285.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GW6000-MS-US30 {208V},208,24.6262,5208,5416.85,330,-2.78802e-06,-3.95732e-05,5.72441e-05,-0.0014516,4.5,500.0,16.4147,171.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW6000-MS-US30 {240V},240,23.4254,5998,6204.09,380,-2.0735e-06,-5.06796e-05,-0.00088241,-0.0011094,4.5,500.0,16.3265,198.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW6000-SBP-US20 {240V},240,22.0414,6009.7,6273.96,300,-2.65546e-06,-4.88359e-05,-0.00427322,-0.00481943,5.6,495.0,20.9132,125.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GW6000A-BP {240V},240,29.8727,6030,6241.04,350,-2.04722e-06,-2.37299e-05,-0.000156299,-0.00111257,11.3,495.0,17.8316,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GW6000A-ES {240V},240,20.7795,6109,6280.59,400,-1.98576e-06,-1.01674e-05,0.000203878,-0.000346084,9.3,480.0,15.7015,360.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW6000A-MS {208V},208,20.9727,6138,6346.46,400,-2.7025e-06,-5.02907e-06,0.000768036,0.00043286,11.5,480.0,15.8662,360.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW6000A-MS {240V},240,20.7795,6109,6280.59,400,-1.98576e-06,-1.01674e-05,0.000203878,-0.000346084,9.3,480.0,15.7015,360.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW60K-SMT-US {480V},480,123.9,61469,62600.5,720,-1.08095e-07,-1.95048e-05,-0.000844687,-0.00037069,7.1,850.0,86.9451,550.0,850.0,NaN,N +GoodWe Technologies Co Ltd: GW7000A-BP {240V},240,30.9599,7059,7315.56,350,-1.8714e-06,-2.23441e-05,0.00108225,-0.000404469,9.48,495.0,20.9016,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GW7000A-ES {240V},240,25.4624,7057,7267.2,400,-1.92279e-06,-4.89749e-05,0.000120641,-0.000138792,9.48,480.0,18.168,210.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW7000A-MS {208V},208,22.8488,7007,7258.37,400,-2.22545e-06,-4.43652e-05,-0.000294639,-0.000335061,9.34,480.0,18.1459,210.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW7000A-MS {240V},240,25.4624,7057,7267.2,400,-1.92279e-06,-4.89749e-05,0.000120641,-0.000138792,9.48,480.0,18.168,210.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW7600-ES-US20 {240V},240,25.3689,7588.2,7834.69,390,-2.09688e-06,-2.97007e-05,-0.00179294,-0.00199465,5.62,500.0,20.089,180.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GW7600-MS-US30 {208V},208,25.5002,6589,6858.35,330,-2.87846e-06,-2.79961e-05,-0.00134097,-0.00168544,4.5,500.0,20.7829,217.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW7600-MS-US30 {240V},240,24.2736,7589,7864.43,380,-2.05941e-06,-4.11517e-05,-0.00119533,-0.000499875,4.5,500.0,20.6959,250.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW7600-SBP-US20 {240V},240,30.8182,7585.5,7917.16,300,-2.03742e-06,-1.63256e-05,-0.00209605,-0.00328808,5.61,495.0,26.3905,158.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GW7600A-BP {240V},240,29.9914,7648,7937.29,350,-1.80177e-06,-2.43109e-05,0.00102835,-0.000548669,9.48,495.0,22.678,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GW7600A-ES {240V},240,23.6388,7644,7879.28,400,-1.80292e-06,-4.54886e-05,3.02154e-06,-0.000274454,9.44,480.0,19.6982,230.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW7600A-MS {208V},208,23.2146,7610,7892.97,400,-2.28314e-06,-4.13397e-05,-0.000671913,-0.000557386,9.58,480.0,19.7324,230.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW7600A-MS {240V},240,23.6388,7644,7879.28,400,-1.80292e-06,-4.54886e-05,3.02154e-06,-0.000274454,9.44,480.0,19.6982,230.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW7700-MS-US30 {208V},208,10.3004,6630,6863.92,330,-1.48365e-06,-5.13242e-05,-0.00269961,-0.00196089,4.5,500.0,20.7998,150.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW7700-MS-US30 {240V},240,22.1448,7678,7913.17,380,-1.17414e-06,-4.99135e-05,-0.000168234,0.000369858,4.5,500.0,20.8241,170.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW8600A-BP {240V},240,27.7456,8680,9015.71,350,-1.62276e-06,-3.03918e-05,0.000685614,-0.00150842,9.47,495.0,25.7592,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GW8600A-ES {240V},240,23.3258,8614,8891.7,400,-1.76225e-06,-3.6493e-05,2.6112e-05,-0.000109434,9.54,480.0,22.2292,260.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW8600A-MS {208V},208,23.3286,8612,8951.83,400,-2.33178e-06,-3.43304e-05,5.07352e-05,0.00014818,9.87,480.0,22.3796,260.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW8600A-MS {240V},240,23.3258,8614,8891.7,400,-1.76225e-06,-3.6493e-05,2.6112e-05,-0.000109434,9.54,480.0,22.2292,260.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW9600-ES-US20 {240V},240,28.6476,9586.2,9912.27,390,-1.80565e-06,-1.28054e-05,-0.00126885,-0.000404749,5.62,500.0,25.4161,225.0,500.0,NaN,Y +GoodWe Technologies Co Ltd: GW9600-MS-US30 {208V},208,44.3245,8301,8644.45,330,-2.96225e-06,-3.65536e-05,-0.00116442,-0.00277616,4.5,500.0,26.1953,182.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW9600-MS-US30 {240V},240,38.8666,9566,9894.55,380,-1.97997e-06,-4.56388e-05,-0.00340117,-0.00393293,4.5,500.0,26.0383,210.0,500.0,NaN,N +GoodWe Technologies Co Ltd: GW9600-SBP-US20 {240V},240,39.6612,9603.1,10008.6,300,-1.56627e-06,-3.78155e-05,-0.00401472,-0.00696902,5.61,495.0,33.3619,200.0,495.0,NaN,N +GoodWe Technologies Co Ltd: GW9600A-BP {240V},240,28.2373,9616,10008,350,-1.70726e-06,-3.60836e-05,0.000431581,-0.00185521,9.5,495.0,28.5943,200.0,495.0,2023-12-11 00:00:00,N +GoodWe Technologies Co Ltd: GW9600A-ES {240V},240,22.5217,9628,9953.88,400,-1.7359e-06,-3.05626e-05,5.5607e-05,-0.000191057,9.4,480.0,24.8847,300.0,480.0,2023-02-13 00:00:00,Y +GoodWe Technologies Co Ltd: GW9600A-MS {208V},208,21.8846,9628,10029,400,-2.22671e-06,-2.76086e-05,0.00043522,6.98734e-05,9.67,480.0,25.0726,300.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW9600A-MS {240V},240,22.5217,9628,9953.88,400,-1.7359e-06,-3.05626e-05,5.5607e-05,-0.000191057,9.4,480.0,24.8847,300.0,480.0,2023-02-13 00:00:00,N +GoodWe Technologies Co Ltd: GW9600H-ES {240V},240,58.5977,9628,10145.8,400,-3.08591e-06,-2.7977e-05,4.45588e-05,3.60718e-06,45.22,480.0,25.3644,300.0,480.0,2023-02-13 00:00:00,Y +Green Solutions (Chengdu) Co Ltd: H12K-US {208V},208,45.8617,10490,10918.9,360,-2.03131e-06,-4.96908e-05,-0.000161767,3.31328e-06,14.5,480.0,30.3302,230.0,480.0,NaN,Y +Green Solutions (Chengdu) Co Ltd: H12K-US {240V},240,23.5967,11930,12340.1,360,-8.94297e-07,-4.81928e-05,-0.00130889,-0.00251017,14.29,480.0,34.278,230.0,480.0,NaN,Y +Gridwiz Co Ltd: Gridwiz-PCS 300 {380V},380,2410.31,300420,309222,870,-3.39798e-08,8.84121e-06,0.0018096,0.000678052,16.7,1100.0,355.427,640.0,1100.0,NaN,N +Guangzhou Sanjing Electric Co Ltd: H2-10K-S4-US {208V},208,72.1324,8798,9055.78,380,-1.58728e-06,-1.76273e-05,0.000853916,-0.000727403,2.9,550.0,23.831,200.0,550.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-10K-S4-US {240V},240,68.2025,10089,10375.8,380,-9.31068e-07,-2.25657e-05,0.000599408,-0.00122226,3.0,550.0,27.3048,200.0,550.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-114K-LS4-US {208V},208,87.2927,9881,10201.6,380,-1.85632e-06,-3.99605e-05,0.000404971,-0.000733843,NaN,510.0,26.8463,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-114K-LS4-US {240V},240,82.9831,11298,11652,380,-1.25756e-06,-3.50364e-05,0.000470481,-0.000119328,NaN,510.0,30.6633,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-12K-S4-US {208V},208,75.1051,10417,10777.1,380,-2.1479e-06,-8.60447e-06,0.00161756,0.00138672,2.8,550.0,28.3607,200.0,550.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-12K-S4-US {240V},240,76.7173,12034,12423.7,380,-1.38558e-06,-2.73826e-05,0.00071282,-0.000830239,3.2,550.0,32.6941,200.0,550.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-5K-LS3-US {208V},208,55.9561,4363,4507.27,380,-5.34493e-06,-1.06298e-05,0.000119515,2.83114e-05,NaN,510.0,11.8612,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-5K-LS3-US {240V},240,57.0673,5067,5216.49,380,-2.88865e-06,-4.20619e-06,0.000195244,0.00110953,NaN,510.0,13.7276,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-76K-LS3-US {208V},208,62.8942,6609,6801.54,380,-1.15769e-06,-7.79718e-06,0.000191452,0.000401243,NaN,510.0,17.8988,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-76K-LS3-US {240V},240,69.1377,7610,7842.17,380,-1.65666e-06,-2.37018e-05,-5.52383e-05,0.00134374,NaN,510.0,20.6373,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-76K-S3-US {208V},208,58.6833,6605,6795.02,380,-2.51473e-06,-1.57962e-05,-0.00012762,-0.00209779,3.1,550.0,17.8816,200.0,550.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-76K-S3-US {240V},240,64.1404,7606,7816.27,380,-1.72715e-06,-1.68571e-05,0.00082446,-0.000596217,3.1,550.0,20.5691,200.0,550.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-96K-LS4-US {208V},208,80.1285,8316,8579.94,380,-1.43766e-06,-3.29468e-05,0.000495217,-0.00139024,NaN,510.0,22.5788,190.0,510.0,NaN,Y +Guangzhou Sanjing Electric Co Ltd: H2-96K-LS4-US {240V},240,93.7419,9605,9903.76,380,-1.68172e-06,-1.32522e-05,0.000925686,0.00314117,NaN,510.0,26.0625,190.0,510.0,NaN,Y +HiQ Solar: TSXL480-10k {480V},480,63.8968,9975,10171.9,750,-1.23006e-06,-1.83212e-05,0.000593869,-0.000584562,8.3,850.0,13.5625,450.0,850.0,2019-02-15 00:00:00,N +Holu Hou Energy LLC: HH9600H-HI {240V},240,22.5217,9628,9953.88,400,-1.7359e-06,-3.05626e-05,5.5607e-05,-0.000191057,9.4,480.0,24.8847,300.0,480.0,NaN,Y +Hongyibo New Energy Technology (Shenzhen) Co Ltd: PCSR10KLNA {240V},240,51.9471,10176.7,10475.4,360,-1.26046e-06,-2.00266e-05,-4.72702e-05,-0.000721728,33.64,430.0,29.0984,280.0,430.0,NaN,Y +Hongyibo New Energy Technology (Shenzhen) Co Ltd: PCSR5KLNA {240V},240,29.3587,5089.67,5247.54,360,-3.6512e-06,-1.51201e-05,0.000125821,0.000551915,22.6,430.0,14.5765,180.0,430.0,NaN,Y +Hongyibo New Energy Technology (Shenzhen) Co Ltd: PCSR6KLNA {240V},240,33.668,6117.18,6297.92,360,-2.58712e-06,-2.03094e-05,0.000191477,-0.000256399,22.99,430.0,17.4942,200.0,430.0,NaN,Y +Hongyibo New Energy Technology (Shenzhen) Co Ltd: PCSR7K6LNA {240V},240,37.4864,7764.72,7993.03,360,-1.60481e-06,-2.20797e-05,-0.000935129,-0.00139184,30.71,430.0,22.2029,220.0,430.0,NaN,Y +Hongyibo New Energy Technology (Shenzhen) Co Ltd: PCSR8KLNA {240V},240,65.6455,8084.16,8326.86,360,-2.93482e-06,-6.00331e-06,-0.000923485,-0.00173197,17.4,430.0,23.1302,250.0,430.0,NaN,Y +Hoymiles Power Electronics Inc: HAS-115LV-USG1 {240V},240,58.3464,9153,9722.41,55,-8.88284e-07,-0.00127949,-0.0237089,-0.329263,6.6,60.0,176.771,50.0,60.0,2024-08-12 00:00:00,N +Hoymiles Power Electronics Inc: HAS-38LV-USG1 {240V},240,36.1281,3646,3845.75,55,1.74379e-06,-0.000674086,-0.0189531,0.314915,5.9865,60.0,69.9227,50.0,60.0,2024-08-12 00:00:00,N +Hoymiles Power Electronics Inc: HAS-48LV-USG1 {240V},240,39.7634,4559,4815.26,55,-4.43583e-07,-0.00115409,-0.0224379,-1.25732,5.9872,60.0,87.5501,50.0,60.0,2024-08-12 00:00:00,N +Hoymiles Power Electronics Inc: HAS-60LV-USG1 {240V},240,39.7634,4559,4815.26,55,-4.43583e-07,-0.00115409,-0.0224379,-1.25732,5.9872,60.0,87.5501,50.0,60.0,2024-08-12 00:00:00,N +Hoymiles Power Electronics Inc: HAS-76LV-USG1 {240V},240,43.5211,7417,7838.26,55,6.30774e-07,-0.000702465,-0.032766,0.442807,6.6685,60.0,142.514,50.0,60.0,2024-08-12 00:00:00,N +Hoymiles Power Electronics Inc: HAS-96LV-USG1 {240V},240,58.3464,9153,9722.41,55,-8.88284e-07,-0.00127949,-0.0237089,-0.329263,6.6,60.0,176.771,50.0,60.0,2024-08-12 00:00:00,N +Hoymiles Power Electronics Inc: HM-1000 {240V},240,1.79562,1032,1068.78,37,-4.86559e-06,-9.50841e-05,-0.000891379,-0.0344255,0.03,48.0,28.886,27.0,48.0,2021-03-01 00:00:00,N +Hoymiles Power Electronics Inc: HM-1000N {240V},240,2.01649,985,1022.72,40,-8.90633e-06,-0.000269782,-0.0383625,-0.0887723,0.11,48.0,25.5679,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HM-1000NT {240V},240,2.01649,985,1022.72,40,-8.90633e-06,-0.000269782,-0.0383625,-0.0887723,0.11,48.0,25.5679,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HM-1000T {240V},240,1.79562,1032,1068.78,37,-4.86559e-06,-9.50841e-05,-0.000891379,-0.0344255,0.03,48.0,28.886,27.0,48.0,2021-03-01 00:00:00,N +Hoymiles Power Electronics Inc: HM-1200 {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,2021-03-01 00:00:00,N +Hoymiles Power Electronics Inc: HM-1200N {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,2023-08-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-1200NT {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,2023-08-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-1200T {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,2021-03-01 00:00:00,N +Hoymiles Power Electronics Inc: HM-1500 {240V},240,3.91094,1551,1609.53,42,-5.37041e-06,-0.000546251,-0.0768296,-0.231668,0.03,48.0,38.3221,36.0,48.0,2021-03-01 00:00:00,N +Hoymiles Power Electronics Inc: HM-1500N {208V},208,5.47553,1440,1498.14,42,-1.06673e-05,-3.17945e-05,0.0104628,-0.00170637,0.01461,48.0,35.6701,36.0,48.0,2024-01-22 00:00:00,N +Hoymiles Power Electronics Inc: HM-1500N {240V},240,2.30443,1439,1492.19,42,-2.34848e-06,-0.000354019,-0.0918936,-0.356898,0.11,48.0,35.5283,36.0,48.0,2023-08-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-1500NT {208V},208,5.47553,1440,1498.14,42,-1.06673e-05,-3.17945e-05,0.0104628,-0.00170637,0.01461,48.0,35.6701,36.0,48.0,2024-01-22 00:00:00,N +Hoymiles Power Electronics Inc: HM-1500NT {240V},240,2.30443,1439,1492.19,42,-2.34848e-06,-0.000354019,-0.0918936,-0.356898,0.11,48.0,35.5283,36.0,48.0,2023-08-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-1500T {240V},240,3.91094,1551,1609.53,42,-5.37041e-06,-0.000546251,-0.0768296,-0.231668,0.03,48.0,38.3221,36.0,48.0,2021-03-01 00:00:00,N +Hoymiles Power Electronics Inc: HM-300N {240V},240,0.675628,295.418,306.286,40,-1.46101e-05,-0.000162032,-0.0323591,-0.154329,0.105,48.0,7.65714,33.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-300NA {240V},240,0.548348,295.42,306.346,40,-1.41845e-05,-0.00023102,-0.0300309,-0.155457,0.108,48.0,7.65864,29.0,48.0,2021-03-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-300NT {240V},240,0.548348,295.418,306.344,40,-1.41845e-05,-0.000231016,-0.0300309,-0.155457,0.108,48.0,7.65859,29.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-350N {240V},240,0.675628,349.496,362.54,40,-1.46101e-05,-0.000283309,-0.0323591,-0.154329,0.105,48.0,9.06349,33.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-350NA {240V},240,0.675628,349.5,362.544,40,-1.46101e-05,-0.000283318,-0.0323591,-0.154329,0.105,48.0,9.06359,33.0,48.0,2021-03-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-350NT {240V},240,0.675628,349.496,362.54,40,-1.46101e-05,-0.000283309,-0.0323591,-0.154329,0.105,48.0,9.06349,33.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-400N {208V},208,1.39075,387.262,402.933,42,-3.70121e-05,-0.000342724,-0.0303585,-0.0672068,0.09,48.0,9.59365,38.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HM-400N {240V},240,0.712961,382.542,396.351,42,-1.0523e-05,-0.000291691,-0.113573,-0.329599,0.105,48.0,9.43693,34.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-400NA {240V},240,0.712961,382.54,396.349,42,-1.0523e-05,-0.000291685,-0.113573,-0.329599,0.105,48.0,9.43688,34.0,48.0,2021-03-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-400NT {208V},208,1.39075,387.262,402.933,42,-3.70121e-05,-0.000342724,-0.0303585,-0.0672068,0.09,48.0,9.59365,38.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HM-400NT {240V},240,0.712961,382.542,396.351,42,-1.0523e-05,-0.000291691,-0.113573,-0.329599,0.105,48.0,9.43693,34.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HM-600N {240V},240,1.00135,591,612.976,37,-6.98155e-06,-0.000214298,-0.0532573,-0.179554,0.11,48.0,16.5669,29.0,48.0,2023-04-21 00:00:00,N +Hoymiles Power Electronics Inc: HM-600NT {240V},240,1.00135,591,612.976,37,-6.98155e-06,-0.000214298,-0.0532573,-0.179554,0.11,48.0,16.5669,29.0,48.0,2023-04-21 00:00:00,N +Hoymiles Power Electronics Inc: HM-700N {240V},240,1.1184,697,722.571,42,-4.53834e-06,-0.00028638,-0.0634212,-0.271915,0.11,48.0,17.2041,33.0,48.0,2023-04-21 00:00:00,N +Hoymiles Power Electronics Inc: HM-700NT {240V},240,1.1184,697,722.571,42,-4.53834e-06,-0.00028638,-0.0634212,-0.271915,0.11,48.0,17.2041,33.0,48.0,2023-04-21 00:00:00,N +Hoymiles Power Electronics Inc: HM-800N {208V},208,2.91615,767,797.921,42,-1.98717e-05,-2.64317e-05,0.00914614,-0.00141587,0.11,48.0,18.9981,34.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HM-800N {240V},240,1.43228,767,795.035,42,-5.42142e-06,-0.000302424,-0.0766967,-0.26529,0.11,48.0,18.9294,34.0,48.0,2023-04-21 00:00:00,N +Hoymiles Power Electronics Inc: HM-800NT {208V},208,2.91615,767,797.921,42,-1.98717e-05,-2.64317e-05,0.00914614,-0.00141587,0.11,48.0,18.9981,34.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HM-800NT {240V},240,1.43228,767,795.035,42,-5.42142e-06,-0.000302424,-0.0766967,-0.26529,0.11,48.0,18.9294,34.0,48.0,2023-04-21 00:00:00,N +Hoymiles Power Electronics Inc: HMS-1000-2T-NA {208V},208,3.65902,965.208,1004.25,42,-1.58224e-05,-2.62167e-05,0.0151609,0.00175276,0.11,48.0,23.9106,38.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1000-2T-NA {240V},240,3.66469,967,1006.11,42,-1.5798e-05,-2.62259e-05,0.0151609,0.0017527,0.11,48.0,23.9551,38.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1000-4D {240V},240,1.79562,1032,1068.78,37,-4.86559e-06,-9.50841e-05,-0.000891379,-0.0344255,0.03,48.0,28.886,27.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1000-4D-NA {240V},240,2.01649,985,1022.72,40,-8.90633e-06,-0.000269782,-0.0383625,-0.0887723,0.11,48.0,25.5679,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1000-4T {240V},240,1.79562,1032,1068.78,37,-4.86559e-06,-9.50841e-05,-0.000891379,-0.0344255,0.03,48.0,28.886,27.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1000-4T-NA {240V},240,2.01649,985,1022.72,40,-8.90633e-06,-0.000269782,-0.0383625,-0.0887723,0.11,48.0,25.5679,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1200-4D {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1200-4D-NA {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1200-4T {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1200-4T-NA {240V},240,3.57171,1213,1263.95,40,-1.33634e-05,-0.000560105,-0.0378031,-0.0868402,0.01461,48.0,31.5987,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1500-4D {240V},240,3.91094,1551,1609.53,42,-5.37041e-06,-0.000546251,-0.0768296,-0.231668,0.03,48.0,38.3221,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1500-4D-NA {240V},240,2.30443,1439,1492.19,42,-2.34848e-06,-0.000354019,-0.0918936,-0.356898,0.11,48.0,35.5283,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1500-4T {240V},240,3.91094,1551,1609.53,42,-5.37041e-06,-0.000546251,-0.0768296,-0.231668,0.03,48.0,38.3221,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1500-4T-NA {240V},240,2.30443,1439,1492.19,42,-2.34848e-06,-0.000354019,-0.0918936,-0.356898,0.11,48.0,35.5283,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1600-4T-NA {240V},240,5.75897,1447,1505.45,42,-1.09035e-05,-3.65223e-05,0.00420468,-0.00503161,0.11,48.0,35.8441,29.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-1800-4T-NA {240V},240,6.62326,1668,1735.6,42,-9.49831e-06,-4.20698e-05,0.00552263,-0.005526,0.11,48.0,41.3239,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-2000-4T-NA {208V},208,7.62731,1926,2004.7,42,-8.25533e-06,-4.62355e-05,0.00695257,-0.00568954,0.11,48.0,47.731,34.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-2000-4T-NA {240V},240,7.6358,1928,2006.4,42,-8.25055e-06,-4.62786e-05,0.00694646,-0.00570045,0.11,48.0,47.7715,34.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-300-1A-NA {240V},240,0.548348,295.42,306.346,40,-1.41845e-05,-0.00023102,-0.0300309,-0.155457,0.108,48.0,7.65864,29.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-300-1D-NA {240V},240,0.548348,295.42,306.346,40,-1.41845e-05,-0.00023102,-0.0300309,-0.155457,0.108,48.0,7.65864,29.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-300-1T-NA {240V},240,0.548348,295.42,306.346,40,-1.41845e-05,-0.00023102,-0.0300309,-0.155457,0.108,48.0,7.65864,29.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-350-1A-NA {240V},240,1.29028,321.796,334.735,42,-4.88806e-05,-3.91637e-05,0.00596992,-0.00346277,0.09,48.0,7.96988,33.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HMS-350-1D-NA {240V},240,0.675628,349.5,362.544,40,-1.46101e-05,-0.000283318,-0.0323591,-0.154329,0.105,48.0,9.06359,33.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-350-1T-NA {240V},240,1.29028,321.796,334.735,42,-4.88806e-05,-3.91637e-05,0.00596992,-0.00346277,0.09,48.0,7.96988,33.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HMS-400-1A-NA {240V},240,1.444,361.796,376.369,42,-4.26101e-05,-2.6014e-05,0.0113116,-0.00170883,0.09,48.0,8.96117,34.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HMS-400-1D-NA {240V},240,0.71205,382.54,396.352,42,-1.05379e-05,-0.000294469,-0.113649,-0.330846,0.105,48.0,9.43694,34.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-400-1T-NA {240V},240,1.444,361.796,376.369,42,-4.26101e-05,-2.6014e-05,0.0113116,-0.00170883,0.09,48.0,8.96117,34.0,48.0,2023-04-11 00:00:00,N +Hoymiles Power Electronics Inc: HMS-450-1A-NA {240V},240,1.62549,411.279,427.915,42,-3.79032e-05,-1.53837e-05,0.0134839,0.00217472,0.09,48.0,10.1884,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-450-1T-NA {240V},240,1.62549,411.279,427.915,42,-3.79032e-05,-1.53837e-05,0.0134839,0.00217472,0.09,48.0,10.1884,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-500-1A-NA {240V},240,1.86121,476.161,495.483,42,-3.28839e-05,-5.73282e-05,0.019983,0.00162563,0.09,48.0,11.7972,38.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-500-1T-NA {240V},240,1.86121,476.161,495.483,42,-3.28839e-05,-5.73282e-05,0.019983,0.00162563,0.09,48.0,11.7972,38.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-600-2D-NA {240V},240,1.00135,591,612.976,37,-6.98155e-06,-0.000214298,-0.0532573,-0.179554,0.11,48.0,16.5669,29.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-600-2T-NA {240V},240,1.00135,591,612.976,37,-6.98155e-06,-0.000214298,-0.0532573,-0.179554,0.11,48.0,16.5669,29.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-700-2D-NA {240V},240,1.1184,697,722.571,42,-4.53834e-06,-0.00028638,-0.0634212,-0.271915,0.11,48.0,17.2041,33.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-700-2T-NA {240V},240,2.49527,642.201,668.127,42,-2.44745e-05,-6.06489e-05,0.00574904,-0.00634713,0.11,48.0,15.9078,33.0,48.0,2023-03-13 00:00:00,N +Hoymiles Power Electronics Inc: HMS-800-2D-NA {240V},240,1.43228,767,795.035,42,-5.42142e-06,-0.000302424,-0.0766967,-0.26529,0.11,48.0,18.9294,34.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMS-800-2T-NA {240V},240,2.80511,726.203,755.46,42,-2.14144e-05,-2.046e-05,0.00769509,-0.00159662,0.11,48.0,17.9871,34.0,48.0,2023-03-13 00:00:00,N +Hoymiles Power Electronics Inc: HMS-900-2T-NA {240V},240,3.05344,827.311,860.531,42,-1.79003e-05,-3.90024e-05,0.0224623,0.00569396,0.11,48.0,20.4888,36.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMT-1600-4T-208-NA {208V},208,11.25,1438,1496.52,38,-2.04554e-05,-0.000283901,-0.000269727,-0.020587,0.1559,48.0,39.3821,28.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMT-1800-4T-208-NA {208V},208,12.1318,1726,1801.56,39.5,-1.9576e-05,-9.58044e-05,0.00419267,-0.00458078,0.176,48.0,45.6091,31.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HMT-2000-4T-208-NA {208V},208,14.5214,1919,2008.3,40,-2.11708e-05,8.4348e-05,0.0191861,0.0149818,0.176,48.0,50.2076,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: HYS-115LV-USG1 {240V},240,20.9849,11575,11971.4,380,-1.44315e-06,-1.02967e-05,-0.00195729,-0.000540832,6.6304,480.0,31.5038,300.0,480.0,2025-08-01 00:00:00,Y +Hoymiles Power Electronics Inc: HYS-38LV-USG1 {240V},240,22.0761,3796,3902.25,380,-2.63666e-06,-1.4634e-05,-0.000738339,-0.000833223,6.0401,480.0,10.2691,300.0,480.0,2025-08-01 00:00:00,Y +Hoymiles Power Electronics Inc: HYS-48LV-USG1 {240V},240,18.5977,4793,4931.03,380,-1.89026e-06,-1.53438e-05,-0.000471363,-0.000837367,5.7606,480.0,12.9764,300.0,480.0,2025-08-01 00:00:00,Y +Hoymiles Power Electronics Inc: HYS-60LV-USG1 {240V},240,18.0031,5995,6176.1,380,-1.758e-06,-1.63291e-05,-0.000775637,-0.00104283,5.8237,480.0,16.2529,300.0,480.0,2025-08-01 00:00:00,Y +Hoymiles Power Electronics Inc: HYS-76LV-USG1 {240V},240,24.0354,7708,7947.05,380,-1.70802e-06,-2.18174e-05,-0.00248231,-0.00312189,6.1397,480.0,20.9133,300.0,480.0,2025-08-01 00:00:00,Y +Hoymiles Power Electronics Inc: HYS-96LV-USG1 {240V},240,23.3389,9641,9963.88,380,-1.64363e-06,-2.15232e-05,-0.00263651,-0.00224876,6.8588,480.0,26.2207,300.0,480.0,2025-08-01 00:00:00,Y +Hoymiles Power Electronics Inc: MIS-1000-2NA {208V},208,3.76094,960.94,1003.85,40,-3.12246e-05,-0.000164766,-0.041366,-0.0282734,0.07,48.0,25.0961,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-1000-2NA {240V},240,3.42581,964.76,1000.86,40,-2.70506e-05,0.000245717,-0.0084065,0.0149815,0.1,48.0,25.0215,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-350-1A-NA {240V},240,1.98266,330.286,341.023,37.5,-5.00306e-05,3.96515e-05,0.0028267,0.0140132,0.07,48.0,9.09393,27.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-350-1NA {240V},240,1.98266,330.286,341.023,37.5,-5.00306e-05,3.96514e-05,0.00282667,0.0140132,0.07,48.0,9.09393,27.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-400-1A-NA {240V},240,2.17176,367.634,379.583,38,-5.026e-05,-5.73755e-05,-0.000361288,-0.00228142,0.07,48.0,9.98903,28.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-400-1NA {240V},240,2.17176,367.634,379.583,38,-5.026e-05,-5.73755e-05,-0.000361288,-0.00228142,0.07,48.0,9.98903,28.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-450-1A-NA {240V},240,1.39434,420.88,433.23,39,-1.09701e-05,-0.000335331,-0.0364072,-0.193668,0.03,48.0,11.1085,30.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-450-1NA {240V},240,1.39434,420.88,433.23,39,-1.09701e-05,-0.000335331,-0.0364072,-0.193668,0.03,48.0,11.1085,30.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-500-1A-NA {208V},208,1.66874,479.556,495.661,40,-4.79434e-06,-0.000380802,-0.0641334,-0.505962,0.02,48.0,12.3915,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-500-1A-NA {240V},240,2.38164,476.36,493.672,40,-2.94462e-05,-2.09938e-05,-0.0202307,-0.0143535,0.07,48.0,12.3418,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-500-1NA {208V},208,1.66874,479.556,495.661,40,-4.79434e-06,-0.000380802,-0.0641334,-0.505962,0.02,48.0,12.3915,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-500-1NA {240V},240,1.66874,476.36,492.36,40,-4.79434e-06,-0.00037394,-0.0641334,-0.505962,0.02,48.0,12.309,32.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-700-2NA {240V},240,7.05668,647.12,667.957,37,-3.37005e-05,-1.68181e-05,0.00112136,-0.000919612,0.09,48.0,18.0529,27.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-800-2NA {240V},240,4.4666,729.58,753.495,38,-2.82667e-05,0.000120153,-0.0276302,-0.000613036,0.09,48.0,19.8288,28.0,48.0,NaN,N +Hoymiles Power Electronics Inc: MIS-900-2NA {240V},240,5.70904,829.78,863.362,39,-4.6062e-05,-0.000594926,-0.0347495,-0.0443689,0.09,48.0,22.1375,30.0,48.0,NaN,N +Hoymiles Power Electronics Inc: THM-1500 {240V},240,3.91094,1551,1609.53,42,-5.37041e-06,-0.000546251,-0.0768296,-0.231668,0.03,48.0,38.3221,36.0,48.0,2021-01-11 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-100KTL-USH0 {800V},800,180.746,100000,101448,1120,-8.38884e-08,-1.08228e-05,9.35388e-07,0.00157648,2.61,1200.0,90.5781,880.0,1200.0,NaN,N +Huawei Technologies Co Ltd: SUN2000-10KTL-USL0 {240V},240,23.5227,10000,10113.8,395,-7.12456e-07,1.17142e-05,0.00370893,-0.000561492,1.98,420.0,25.6046,370.0,420.0,2018-10-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-114KTL-USL0 {240V},240,23.129,11400,11537.8,395,-6.96658e-07,1.25184e-05,0.00327633,-0.000162584,1.97,420.0,29.2097,370.0,420.0,2018-10-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-25KTL-US {480V},480,78.4621,25000,25444.6,730,-2.30386e-07,-1.93273e-05,0.000111025,0.000343536,1.0,800.0,34.8556,560.0,800.0,NaN,N +Huawei Technologies Co Ltd: SUN2000-30KTL-US {480V},480,81.4585,30000,30562.3,730,-2.55477e-07,-1.92647e-05,5.54439e-05,0.000349618,1.0,800.0,41.8662,560.0,800.0,NaN,N +Huawei Technologies Co Ltd: SUN2000-33KTL-US {480V},480,74.8561,33000,33537.8,720,-1.96602e-07,-1.88654e-05,-0.00128955,-0.000566147,1.8,850.0,46.5802,460.0,850.0,2018-10-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-36KTL-US {480V},480,66.6081,36000,36592.3,720,-1.76135e-07,-1.6263e-05,-0.00098733,-0.000287463,1.8,850.0,50.8227,490.0,850.0,2018-10-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-38KTL-USL0 {240V},240,13.9107,3800,3837.15,395,-1.34153e-06,1.46491e-05,0.00191908,-0.0012379,2.18,420.0,9.71431,370.0,420.0,2019-01-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-40KTL-US {480V},480,57.187,40000,40649.7,720,-1.04961e-07,-1.78963e-05,-0.00210224,-0.00383923,1.8,850.0,56.4579,530.0,850.0,2018-10-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-5KTL-USL0 {240V},240,15.6897,5000,5059.37,395,-1.72312e-06,2.06955e-05,0.00060673,-0.00116003,2.07,420.0,12.8085,370.0,420.0,2019-01-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-76KTL-USL0 {240V},240,13.8046,7600,7698.95,395,-1.12172e-06,1.48452e-05,0.00387849,0.00139315,2.06,420.0,19.491,370.0,420.0,2019-01-15 00:00:00,N +Huawei Technologies Co Ltd: SUN2000-9KTL-USL0 {240V},240,19.2128,9000,9096.47,395,-6.87441e-07,1.04806e-05,0.00161412,0.00240734,1.97,420.0,23.029,370.0,420.0,2018-10-15 00:00:00,N +Huizhou Roypow Technology Co Ltd: SUN10000S-U {240V},240,95.0181,10111,10589.4,300,-2.37046e-06,-6.15405e-05,0.000385576,-0.00175458,36.53,440.0,35.2979,200.0,440.0,2025-01-02 00:00:00,Y +Huizhou Roypow Technology Co Ltd: SUN12000S-U {240V},240,97.5302,12079,12675.9,300,-2.13507e-06,-7.09296e-05,7.02434e-05,-0.00198995,36.44,440.0,42.2529,200.0,440.0,2025-01-02 00:00:00,Y +Huizhou Roypow Technology Co Ltd: SUN15000S-U {240V},240,78.6168,14987,15755.4,300,-1.44242e-06,-8.34981e-05,-0.00158026,-0.00530511,35.81,440.0,52.518,200.0,440.0,2025-01-02 00:00:00,Y +Hyperian Energy Inc: ST2-100i {240V},240,40.6725,9956,10242.5,370,-8.52612e-07,-1.75712e-05,-0.00101645,0.000543682,2.5,440.0,27.6826,300.0,440.0,NaN,Y +Hyperian Energy Inc: ST2-114i {240V},240,43.8746,11371,11713.1,370,-1.08852e-06,-1.40856e-05,-0.00114539,0.000480521,2.5,440.0,31.657,300.0,440.0,NaN,Y +Hyperian Energy Inc: ST2-120i {240V},240,46.6908,11968,12332.9,370,-1.11419e-06,-1.34943e-05,-0.0010638,0.00071439,2.5,440.0,33.3322,300.0,440.0,NaN,Y +Hyperian Energy Inc: ST2-76i {240V},240,32.7645,7581,7788.07,370,-5.11345e-07,-2.14221e-05,-0.00102077,-0.00090399,2.5,440.0,21.0488,300.0,440.0,NaN,Y +Hyperian Energy Inc: ST2-96i {240V},240,40.8803,9573,9845.47,370,-8.36577e-07,-1.66676e-05,-0.000586635,0.00132548,2.5,440.0,26.6094,300.0,440.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1000TL U B360 {360V},360,3055.18,1000000,1.02952e+06,632,-2.42207e-08,1.61353e-05,0.00175646,0.000655446,80.0,740.0,1629,524.0,740.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1110TL U B400 {400V},400,3330.12,1110000,1.14019e+06,660,-1.94564e-08,4.58937e-06,9.02638e-05,-0.000974507,80.0,740.0,1727.57,580.0,740.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1140TL U B410 {410V},410,3944.94,1027752,1.05576e+06,668,-1.68859e-08,9.15741e-06,0.000906328,0.000181111,2550.2775,800.0,1580.48,595.0,800.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1165TL U B420 {420V},420,3313.4,1165000,1.19508e+06,675,-1.67424e-08,4.93974e-06,0.00099685,-0.000564912,80.0,740.0,1770.48,610.0,740.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1190TL U B430 {430V},430,3836.03,1048594,1.07642e+06,682,-1.58856e-08,6.62807e-06,0.000797972,-0.000169892,2550.2775,800.0,1578.34,624.0,800.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1220TL U B440 {440V},440,4084.07,1099306,1.12815e+06,689,-1.53926e-08,7.2535e-06,0.000771096,-2.17364e-05,2550.2775,800.0,1637.37,638.0,800.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1245TL U B480 {480V},480,2515.66,1042220,1.07626e+06,949,-1.70408e-08,1.23664e-05,0.0005613,0.000413354,459.07241666666664,1200.0,1134.09,697.0,1200.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1250TL U B450 {450V},450,3971.42,1114104,1.14275e+06,696,-1.42253e-08,6.75845e-06,0.00101053,0.000244572,2550.2775,800.0,1641.89,652.0,800.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1275TL U B460 {460V},460,3899.45,1128476,1.15649e+06,703,-1.27866e-08,9.83512e-06,0.0014183,0.00113901,2550.2775,800.0,1645.07,666.0,800.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1665TL U B640 {640V},640,4143.08,1367076,1.40669e+06,1060,-1.08544e-08,1.01584e-05,0.000560052,0.000166979,459.07241666666664,1200.0,1327.06,919.0,1200.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1690TL U B650 {650V},650,4207.38,1375282,1.4144e+06,1067,-1.12499e-08,1.05104e-05,0.000581217,0.000394024,459.07241666666664,1200.0,1325.59,933.0,1200.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1715TL U B660 {660V},660,4586.19,1390614,1.43035e+06,1074,-1.08453e-08,1.0272e-05,0.000831419,0.000492463,459.07241666666664,1200.0,1331.79,948.0,1200.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1740TL U B670 {670V},670,4199.51,1272412,1.30853e+06,1081,-1.15784e-08,8.94726e-06,0.000372172,-5.71362e-05,459.07241666666664,1200.0,1210.48,962.0,1200.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 1800TL U B690 {690V},690,3366.82,1300644,1.33621e+06,1081,-1.13927e-08,6.44885e-06,3.12978e-05,-0.000175287,459.07241666666664,1200.0,1236.09,962.0,1200.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V},600,11262.8,3095300,3.17336e+06,1170,-4.21009e-09,2.27256e-05,-0.000139208,-0.000319461,2892.524762,1300.0,2712.27,857.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C615 {615V},615,11961,3219880,3.29744e+06,1180,-5.25787e-09,3.19167e-07,2.17703e-06,-0.00229439,2892.524762,1300.0,2794.44,877.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C630 {630V},630,11702.1,3239420,3.32334e+06,1185,-4.2805e-09,2.01448e-05,0.000257163,0.000332895,2892.524762,1300.0,2804.51,894.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C645 {645V},645,12105.8,3304620,3.38164e+06,1198,-4.07007e-09,3.00154e-05,0.000247807,0.00139054,2892.524762,1300.0,2822.74,919.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C660 {660V},660,12628.6,3377600,3.45348e+06,1198,-4.44165e-09,2.1513e-05,0.000134492,0.000198214,2804.839,1300.0,2882.71,940.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C675 {675V},675,12474.2,3452700,3.52443e+06,1200,-4.27149e-09,2.03591e-05,3.31557e-05,1.67146e-05,2804.839036,1300.0,2937.02,960.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C690 {690V},690,12948.8,3535560,3.6014e+06,1200,-4.10356e-09,2.23763e-05,-3.9194e-05,-0.000137899,2804.839035560345,1300.0,3001.17,981.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 610TL U B220 {220V},220,2503.73,610000,630094,590,-4.96833e-08,1.85548e-05,0.00191909,0.000881007,80.0,740.0,1067.96,440.0,740.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 830TL U B300 {300V},300,2560.86,830000,855294,590,-2.75352e-08,1.04866e-05,0.00118074,-0.000175057,80.0,740.0,1449.65,440.0,740.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN 915TL U B330 {330V},330,2906.41,915000,941368,613,-2.43505e-08,4.99294e-06,0.000656289,-0.000909466,80.0,740.0,1535.67,485.0,740.0,NaN,Y +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C450 {450V},450,10184.4,2306000,2.38981e+06,1088,-7.26936e-09,1.60752e-05,0.000975641,0.000253129,2700.109833024119,1300.0,2196.52,650.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C480 {480V},480,10826.2,2467620,2.55379e+06,1088,-6.98024e-09,1.16604e-05,0.000618682,-0.000443928,2700.109833024119,1300.0,2347.24,670.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C578 {578V},578,10906.8,2881480,2.96317e+06,1088,-5.10357e-09,1.97034e-05,0.000425879,0.000355566,2892.5247619047623,1300.0,2723.5,826.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C600 {600V},600,11276.8,3095300,3.17344e+06,1170,-4.22905e-09,2.27182e-05,-0.000134121,-0.000305967,2892.5247619047623,1300.0,2712.34,857.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C630 {630V},630,11741.3,3239420,3.32335e+06,1185,-4.29643e-09,2.01646e-05,0.000278119,0.000364001,2892.5247619047623,1300.0,2804.52,894.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C645 {645V},645,12082.1,3304620,3.38159e+06,1198,-4.05772e-09,2.98284e-05,0.000222894,0.00133956,2892.5247619047623,1300.0,2822.7,919.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C660 {660V},660,12594,3377600,3.45344e+06,1198,-4.41196e-09,2.14075e-05,0.000113524,0.000155296,2804.839035560345,1300.0,2882.67,940.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C690 {690V},690,12948.8,3535560,3.6014e+06,1200,-4.10356e-09,2.23763e-05,-3.9194e-05,-0.000137899,2804.839035560345,1300.0,3001.17,981.0,1300.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V},600,14811.1,2582000,2.64406e+06,1200,-6.22944e-09,1.10852e-05,0.000798793,-6.47505e-07,7080.0,1500.0,2203.38,938.0,1500.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C650 {650V},650,15417.9,2762400,2.8279e+06,1200,-5.64305e-09,1.00445e-05,0.000745163,-0.000315072,7080.0,1500.0,2356.58,1010.0,1500.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C690 {690V},690,13067.1,2983400,3.04144e+06,1250,-3.50307e-09,1.07015e-05,0.00105462,-0.000110141,7080.0,1500.0,2433.15,1085.0,1500.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C730 {730V},730,15130.8,3102800,3.15436e+06,1300,-3.92504e-09,1.08542e-05,0.00101901,0.000378323,7080.0,1500.0,2426.43,1136.0,1500.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C750 {750V},750,15572,3237100,3.29754e+06,1300,-3.70123e-09,9.67648e-06,0.000875533,-1.33101e-05,7080.0,1500.0,2536.57,1165.0,1500.0,NaN,N +INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C760 {760V},760,13986.1,3240000,3.29788e+06,1350,-2.61674e-09,8.93109e-06,0.00090061,-0.000256285,7080.0,1500.0,2442.88,1180.0,1500.0,NaN,N +Jackery Inc: GVI-HR-11K4-USG {240V},240,18.1711,11084,11377.1,380,2.32863e-07,-1.54646e-05,-0.00947891,0.0305136,15.36,450.0,29.9398,245.0,450.0,NaN,Y +Jackery Inc: GVI-HR-7K6-USG {240V},240,19.2021,7394,7590.33,380,9.45009e-08,-2.69467e-06,0.00152037,0.00471501,16.33,450.0,19.9746,175.0,450.0,NaN,Y +Jiangsu RCT Power Energy Technology Co Ltd: Power Storage DC US-80 PRO {208V},208,41.2034,7015,7244.95,360,-2.69339e-06,-4.13342e-05,-0.000193439,-0.000562648,0.3,420.0,20.1249,220.0,420.0,NaN,Y +Jiangsu RCT Power Energy Technology Co Ltd: Power Storage DC US-80 PRO {240V},240,38.6265,8032.2,8267.26,360,-2.14409e-06,-4.1133e-05,-0.000153539,-0.00107544,0.4025,420.0,22.9646,220.0,420.0,NaN,Y +Jiangsu RCT Power Energy Technology Co Ltd: Power Storage DC US-80 {208V},208,41.3127,7015,7245.09,360,-2.70641e-06,-4.13425e-05,-0.000204197,-0.000575843,0.3,420.0,20.1252,220.0,420.0,2024-08-01 00:00:00,Y +Jiangsu RCT Power Energy Technology Co Ltd: Power Storage DC US-80 {240V},240,38.6265,8032.2,8267.26,360,-2.14409e-06,-4.1133e-05,-0.000153539,-0.00107544,0.4025,420.0,22.9646,220.0,420.0,2024-08-01 00:00:00,Y +Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-114kW {240V},240,77.7769,11257,11648.2,410,-2.62115e-06,-2.94046e-06,0.000974786,0.000393104,10.379,550.0,28.4102,210.0,550.0,NaN,Y +Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-76kW {240V},240,53.3491,7572,7778.15,410,-6.93619e-07,-3.36973e-06,7.2168e-05,-0.000207948,10.938,550.0,18.9711,144.0,550.0,NaN,Y +Jiangsu Weiheng Intelligent Technology Co Ltd: SHD-96kW {240V},240,60.2528,9660,9948.45,410,-1.563e-06,-7.14687e-06,0.000842449,9.55895e-05,11.042,550.0,24.2645,180.0,550.0,NaN,Y +JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03C1 {480V},480,465.855,127819,130425,832,-9.98944e-08,1.71187e-05,0.00262041,0.00044902,8.34,950.0,156.76,700.0,950.0,NaN,N +JingTsing Technology Ltd: JTES-PCS125K-1000/480-L03L1 {480V},480,465.855,127819,130425,832,-9.98944e-08,1.71187e-05,0.00262041,0.00044902,8.34,950.0,156.76,700.0,950.0,NaN,N +JingTsing Technology Ltd: JTES-PCS450K-1600/740-L03C1 {740V},740,1362.16,459563,466653,1400,-1.70145e-08,5.12775e-06,0.000858813,0.000107476,3.57,1600.0,333.323,1100.0,1600.0,NaN,N +Jinko Solar Co Ltd: JKS-R-11P12-US {240V},240,19.6249,11406,11710.4,380,1.64665e-07,-1.31236e-05,-0.00857451,0.0382415,15.36,450.0,30.8169,245.0,450.0,2024-01-22 00:00:00,Y +Jinko Solar Co Ltd: JKS-R-7P12-US {240V},240,19.7473,7604,7805.91,380,9.18811e-08,-2.69402e-06,0.0015204,0.00471397,16.33,450.0,20.5419,175.0,450.0,2024-01-22 00:00:00,Y +KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIK0 {480V},480,88.7015,109765,111509,854,-8.15479e-08,9.78636e-06,0.00251055,0.000239877,5.0,1300.0,130.573,705.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 110 TL3 M1 WM OD IIKX {480V},480,88.7015,109765,111509,854,-8.15479e-08,9.78636e-06,0.00251055,0.000239877,5.0,1300.0,130.573,705.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 125 TL3 M1 WM OD IIP0 {600V},600,107.102,138663,140510,981,-5.12338e-08,9.69607e-06,0.00252363,0.000435938,5.57,1300.0,143.232,875.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 125 TL3 M1 WM OD IIPX {600V},600,107.102,138663,140510,981,-5.12338e-08,9.69607e-06,0.00252363,0.000435938,5.57,1300.0,143.232,875.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 137 TL3 M1 WM OD IIP0 {600V},600,107.102,138663,140510,981,-5.12338e-08,9.69607e-06,0.00252363,0.000435938,5.57,1300.0,143.232,875.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 137 TL3 M1 WM OD IIPX {600V},600,107.102,138663,140510,981,-5.12338e-08,9.69607e-06,0.00252363,0.000435938,5.57,1300.0,143.232,875.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQ0 {660V},660,118.547,151228,153101,1045,-4.22377e-08,9.35684e-06,0.00263679,0.000550823,5.25,1300.0,146.508,960.0,1300.0,NaN,N +KACO new energy GmbH: KACO blueplanet 150 TL3 M1 WM OD IIQX {660V},660,118.547,151228,153101,1045,-4.22377e-08,9.35684e-06,0.00263679,0.000550823,5.25,1300.0,146.508,960.0,1300.0,NaN,N +Kowint Energy (Shenzhen) Co Ltd: K-PH125-B-US03 {480V},480,76.8966,125015,127090,1010.1,-4.18203e-08,3.29466e-06,0.0012416,0.00047798,60.0,1300.1,125.819,720.015,1300.1,NaN,N +Kowint Energy (Shenzhen) Co Ltd: KSL-12KU-A {240V},240,53.8336,12137.1,12633,360,-1.53908e-06,-4.73946e-05,0.00180521,0.00137538,19.85,430.0,35.0918,200.0,430.0,NaN,Y +Kowint Energy (Shenzhen) Co Ltd: KSL-12KU-B {240V},240,51.8788,12213.5,12699,360,-1.35354e-06,-3.77916e-05,0.00232624,0.00357488,13.202,430.0,35.275,200.0,430.0,NaN,Y +Kowint Energy (Shenzhen) Co Ltd: KSL-16KU-A {240V},240,71.7532,16130.9,16782.1,360,-1.09342e-06,-4.45216e-05,0.000541506,0.000632993,19.23,430.0,46.617,220.0,430.0,NaN,Y +Kowint Energy (Shenzhen) Co Ltd: KSL-16KU-B {240V},240,67.3029,16198.8,16830.2,360,-8.96976e-07,-1.12505e-05,0.00529846,0.00964609,20.465,430.0,46.7505,220.0,430.0,NaN,Y +Kowint Energy (Shenzhen) Co Ltd: KSL-8KU-A {240V},240,35.0745,8110.97,8429.44,360,-2.04075e-06,-3.34508e-05,0.00211012,0.00260777,20.205,430.0,23.4151,150.0,430.0,NaN,Y +Kowint Energy (Shenzhen) Co Ltd: KSL-8KU-B {240V},240,38.6364,8180.92,8510.16,360,-2.45185e-06,-2.9642e-05,0.00225032,0.0025515,19.254,430.0,23.6393,150.0,430.0,NaN,Y +LG Electronics Inc: A005KEEN261 {208V},208,20.2513,5000,5122.61,400,-3.30815e-06,1.85138e-05,0.00309169,-0.000388878,1.85,450.0,12.8065,350.0,450.0,2020-05-11 00:00:00,N +LG Electronics Inc: A005KEEN261 {240V},240,22.3745,5000,5099.83,400,-2.99967e-06,-8.75854e-06,0.00205564,-0.00246704,2.05,450.0,12.7496,350.0,450.0,2020-05-11 00:00:00,N +LG Electronics Inc: D007KEEN261 {208V},208,29.7963,6656,6853.49,380,-2.88247e-06,-1.27884e-05,-0.000878463,0.000458779,1.15,450.0,18.0355,270.0,450.0,2020-05-11 00:00:00,Y +LG Electronics Inc: D007KEEN261 {240V},240,29.0144,7680,7888.01,380,-2.27532e-06,-1.77519e-05,-0.00171207,-0.00031384,1.19,450.0,20.7579,270.0,450.0,2020-05-11 00:00:00,Y +LG Electronics Inc: LG340M1K-L5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG340M1K-L5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG345M1K-L5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG345M1K-L5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG350M1K-L5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG350M1K-L5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG355A1C-A5 {208V},208,3.29908,320,334.905,35,-0.000113446,-0.000428156,-0.00708717,-0.0460783,0.85,42.0,9.5687,32.0,42.0,NaN,N +LG Electronics Inc: LG355A1C-A5 {240V},240,2.38896,320,330.533,35,-6.48304e-05,1.92052e-05,-0.00396893,-0.0286565,0.16,42.0,9.44379,32.0,42.0,NaN,N +LG Electronics Inc: LG355M1C-N5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG355M1C-N5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG355M1K-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG355M1K-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG360A1C-A5 {208V},208,3.29908,320,334.905,35,-0.000113446,-0.000428156,-0.00708717,-0.0460783,0.85,42.0,9.5687,32.0,42.0,NaN,N +LG Electronics Inc: LG360A1C-A5 {240V},240,2.38896,320,330.533,35,-6.48304e-05,1.92052e-05,-0.00396893,-0.0286565,0.16,42.0,9.44379,32.0,42.0,NaN,N +LG Electronics Inc: LG360A1K-V5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG360A1K-V5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG360M1C-N5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG360M1C-N5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG360M1K-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG360M1K-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG365A1C-A5 {208V},208,3.29908,320,334.905,35,-0.000113446,-0.000428156,-0.00708717,-0.0460783,0.85,42.0,9.5687,32.0,42.0,NaN,N +LG Electronics Inc: LG365A1C-A5 {240V},240,2.38896,320,330.533,35,-6.48304e-05,1.92052e-05,-0.00396893,-0.0286565,0.16,42.0,9.44379,32.0,42.0,NaN,N +LG Electronics Inc: LG365A1C-V5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG365A1C-V5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG365A1K-V5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG365A1K-V5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG365M1C-N5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG365M1C-N5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG365M1K-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG365M1K-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG370A1C-A5 {208V},208,3.29908,320,334.905,35,-0.000113446,-0.000428156,-0.00708717,-0.0460783,0.85,42.0,9.5687,32.0,42.0,NaN,N +LG Electronics Inc: LG370A1C-A5 {240V},240,2.38896,320,330.533,35,-6.48304e-05,1.92052e-05,-0.00396893,-0.0286565,0.16,42.0,9.44379,32.0,42.0,NaN,N +LG Electronics Inc: LG370A1C-V5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG370A1C-V5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG370M1C-N5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG370M1C-N5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG370M1K-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG370M1K-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG375A1C-V5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG375A1C-V5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG375M1C-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG375M1C-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG375M1K-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG375M1K-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG380A1C-V5 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG380A1C-V5 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LG380M1C-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG380M1C-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG380M1K-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG380M1K-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG385M1C-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG385M1C-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG395A1C-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG395A1C-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG400A1C-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG400A1C-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LG405A1C-A6 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,NaN,N +LG Electronics Inc: LG405A1C-A6 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,NaN,N +LG Electronics Inc: LM320UE-A2 {208V},208,2.28264,322,335.406,35,-9.05686e-05,-0.000227836,-0.00852515,-0.0461902,0.11,42.0,9.58302,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: LM320UE-A2 {240V},240,2.26825,321,331.536,35,-6.16107e-05,2.14005e-05,-0.0059188,-0.0362561,0.15,42.0,9.47245,32.0,42.0,2020-05-01 00:00:00,N +LG Electronics Inc: P250KH53231 {480V},480,807.91,250425,258041,881,-1.79916e-08,1.93898e-05,0.00117843,0.00119695,4.21,1000.0,292.895,750.0,1000.0,NaN,N +LG Energy Solution Ltd: SHB-G1-050-US {240V},240,21.4902,4982.8,5201.83,300,-3.38565e-06,-5.11115e-05,-0.00207779,-0.00448311,5.6,495.0,17.3394,105.0,495.0,NaN,N +LG Energy Solution Ltd: SHB-G1-060-US {240V},240,22.0414,6009.7,6273.96,300,-2.65546e-06,-4.88359e-05,-0.00427322,-0.00481943,5.6,495.0,20.9132,125.0,495.0,NaN,N +LG Energy Solution Ltd: SHB-G1-076-US {240V},240,30.8182,7585.5,7917.16,300,-2.03742e-06,-1.63256e-05,-0.00209605,-0.00328808,5.61,495.0,26.3905,158.0,495.0,NaN,N +LG Energy Solution Ltd: SHB-G1-096-US {240V},240,39.6612,9603.1,10008.6,300,-1.56627e-06,-3.78155e-05,-0.00401472,-0.00696902,5.61,495.0,33.3619,200.0,495.0,2025-01-13 00:00:00,N +LG Energy Solution Ltd: SHB-G1-114-US {240V},240,39.3275,11391.9,11908.6,300,-1.56872e-06,-3.10692e-05,-0.00439272,-0.0056996,5.61,495.0,39.6954,235.0,495.0,NaN,N +LS Energy Solutions LLC: PBE-5140-R61-1A0-1000 {480V},480,350.19,140485,143375,935,-5.82868e-08,1.67581e-05,0.00186472,0.00109506,1.5,1150.0,153.342,720.0,1150.0,2021-08-02 00:00:00,N +LS Energy Solutions LLC: PBE-6140-R61-1A0-1000 {600V},600,350.048,139449,141900,1125,-4.74743e-08,1.17789e-05,0.000949759,-3.77734e-05,1.58,1350.0,126.133,900.0,1350.0,2021-08-02 00:00:00,N +LeadSolar Energy Co Ltd: LS600 {240V},240,1.95665,500,524.882,36,-3.04951e-05,-0.000355022,0.0366465,-0.0253102,0.09,45.0,14.5801,27.0,45.0,2019-05-01 00:00:00,N +LeadSolar Energy Co Ltd: LS600X {240V},240,8.2302,708,733.855,57,-2.34019e-05,-5.25331e-05,0.0127127,-0.00168024,0.16,64.0,12.8746,50.0,64.0,2018-10-15 00:00:00,N +LeadSolar Energy Co Ltd: LS700S {208V},208,4.99395,606,634.707,54,-2.84017e-05,-0.000650355,0.0445049,-0.0128514,0.21,56.0,11.7538,52.0,56.0,NaN,N +Liniotech Energy Inc: LNT10K0228UL {208V},208,54.3475,10186,10560.2,360,-1.71758e-06,-1.83118e-05,-0.000733476,-0.000439537,16.94,480.0,29.3338,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT10K0228UL {240V},240,54.2141,10147,10509,360,-1.73767e-06,-1.81949e-05,-0.000673176,-0.000317833,18.0,480.0,29.1916,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT12K0228UL {208V},208,54.056,10186,10559.8,360,-1.70398e-06,-1.83483e-05,-0.000763056,-0.00046152,16.94,480.0,29.3328,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT12K0228UL {240V},240,54.222,10140,10501.5,360,-1.72665e-06,-1.82761e-05,-0.000567918,-0.00026723,16.67,480.0,29.1709,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT5K0228UL {208V},208,25.8481,5020,5195.39,360,-2.34121e-06,-3.28822e-05,-0.000773753,-0.00227295,15.0,480.0,14.4317,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT5K0228UL {240V},240,25.4303,5040,5196.39,360,-1.76159e-06,-4.08294e-05,-0.000662743,-0.00438374,15.0,480.0,14.4344,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT6K0228UL {208V},208,39.3472,6124,6337.1,360,-2.27837e-06,-2.94606e-05,-0.000829423,-0.000529414,19.2,480.0,17.6031,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT6K0228UL {240V},240,39.6167,6149,6335.21,360,-1.56475e-06,-3.58904e-05,-0.000469452,-0.000730717,19.2,480.0,17.5978,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT7K0228UL {208V},208,41.0561,7648,7919.97,360,-2.25575e-06,-1.9822e-05,-0.000763518,-0.000587419,15.0,480.0,21.9999,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT7K0228UL {240V},240,53.0573,7647,7921.64,360,-2.83516e-06,-1.80857e-05,-0.00030204,-8.8294e-05,15.0,480.0,22.0045,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT8K0228UL {208V},208,43.6503,8060,8356.75,360,-2.19669e-06,-1.82578e-05,-0.00067304,-0.00032298,17.78,480.0,23.2132,200.0,480.0,NaN,Y +Liniotech Energy Inc: LNT8K0228UL {240V},240,43.5443,8047,8334.67,360,-2.21153e-06,-1.82488e-05,-0.00066946,-0.000325811,15.0,480.0,23.1519,200.0,480.0,NaN,Y +Lion Energy: #50170167 Sanctuary 8K {208V},208,45.8909,7827,8307.53,370,-3.75867e-06,-3.72495e-05,0.000660313,2.00466e-05,14.2,425.0,22.4528,240.0,425.0,2023-04-03 00:00:00,Y +Lion Energy: #50170167 Sanctuary 8K {240V},240,47.1481,7898,8340.57,370,-3.21789e-06,-4.45834e-05,0.000557686,-0.00053097,18.8,425.0,22.5421,240.0,425.0,2023-04-03 00:00:00,Y +Lion Energy: #50170168 {240V},240,65.6455,8084,8326.69,360,-2.93482e-06,-6.00257e-06,-0.000923485,-0.00173197,17.4,430.0,23.1297,250.0,430.0,2024-05-21 00:00:00,Y +Lion Energy: Lion Hybrid Inverter 12kW {240V},240,65.7917,8084,8326.87,360,-2.95092e-06,-5.90796e-06,-0.000931502,-0.00173603,17.4,430.0,23.1302,250.0,430.0,2026-05-21 00:00:00,Y +Lion Energy: Lion Hybrid Inverter 15kW {240V},240,51.9686,10177,10475.7,360,-1.26033e-06,-2.0449e-05,-5.21533e-05,-0.000766056,33.64,430.0,29.0991,280.0,430.0,2026-05-21 00:00:00,Y +Lion Energy: Sanctuary 3 Inverter 12kW {240V},240,38.5579,8181,8510.29,360,-2.45017e-06,-2.96397e-05,0.00224558,0.00254761,19.254,430.0,23.6397,150.0,430.0,2026-05-21 00:00:00,Y +Lion Energy: Sanctuary 3 Inverter 18kW {240V},240,51.9675,12214,12699.8,360,-1.35886e-06,-3.77971e-05,0.00236429,0.00361106,13.202,430.0,35.2773,200.0,430.0,2026-05-21 00:00:00,Y +Lion Energy: Sanctuary 3 Inverter 24kW {240V},240,67.3944,16199,16830.4,360,-9.00267e-07,-1.12249e-05,0.00529221,0.00962936,20.465,430.0,46.7511,220.0,430.0,2026-05-21 00:00:00,Y +Lite-On Technology Corporation: IN-HP5113US {240V},240,33.1607,11361,11690.4,380,-1.20274e-06,-1.13329e-05,0.00017709,-0.000252858,13.3488,500.0,30.7642,257.0,500.0,NaN,Y +Lite-On Technology Corporation: IN-HP5123US {120V},120,84.367,9018.6,9408.73,360,-1.54995e-06,-1.89281e-06,0.00139151,-0.00187704,4.0,500.0,26.1354,285.0,500.0,2025-04-21 00:00:00,Y +Lite-On Technology Corporation: IN-HP5123US {240V},240,84.367,9018.6,9408.73,360,-1.54995e-06,-1.89281e-06,0.00139151,-0.00187704,4.0,500.0,26.1354,285.0,500.0,2025-04-21 00:00:00,Y +Lunar Energy Inc: 10-005025 {240V},240,106.936,9675,10063.1,415,-1.9309e-06,8.98385e-05,0.0048026,4.20113e-05,29.61,450.0,24.2485,380.0,450.0,2025-10-21 00:00:00,Y +MANGO POWER TECH INC: LBZ-PV-400 {208V},208,1.8632,400.2,412.757,45.5,-1.64966e-05,-0.000370656,-0.00191104,-0.149622,0.05,55.0,9.07159,36.0,55.0,NaN,N +MANGO POWER TECH INC: LBZ-PV-400 {240V},240,1.79999,400.12,411.985,45.5,-4.86489e-06,-0.0005913,-0.00847174,-0.525774,0.05,55.0,9.05462,36.0,55.0,NaN,N +MANGO POWER TECH INC: LBZ-PV-500 {208V},208,2.7933,499.18,517.432,45.5,-4.22556e-05,-0.00057306,0.00741196,-0.048216,0.05,55.0,11.3721,36.0,55.0,NaN,N +MANGO POWER TECH INC: LBZ-PV-500 {240V},240,2.2353,500.36,517.426,45.5,-2.95627e-05,-0.000909955,-0.00889419,-0.103473,0.05,55.0,11.372,36.0,55.0,NaN,N +MANGO POWER TECH INC: M Hybrid Inverter 12kW {208V},208,45.8617,10499,10928.4,360,-2.03131e-06,-4.9692e-05,-0.000161767,3.31328e-06,14.5,480.0,30.3567,230.0,480.0,NaN,Y +MANGO POWER TECH INC: M Hybrid Inverter 12kW {240V},240,23.5967,11933,12343.2,360,-8.94297e-07,-4.81999e-05,-0.00130889,-0.00251017,14.29,480.0,34.2867,230.0,480.0,NaN,Y +MPP SOLAR INC: LVX 12KW WP {120V},120,79.4493,9018.6,9411.59,360,-1.29986e-06,-4.88045e-06,0.00204238,-0.000538938,4.0,500.0,26.1433,285.0,500.0,NaN,Y +MPP SOLAR INC: LVX 12KW WP {240V},240,79.4493,9018.6,9411.59,360,-1.29986e-06,-4.88045e-06,0.00204238,-0.000538938,4.0,500.0,26.1433,285.0,500.0,NaN,Y +MidNite Power Inc: MN 15-12KW-AIO {208V},208,54.0027,10193,10567.1,360,-1.70166e-06,-1.84269e-05,-0.000774997,-0.000456428,18.56,480.0,29.3532,200.0,480.0,NaN,Y +MidNite Power Inc: MN 15-12KW-AIO {240V},240,53.8737,10135,10496.5,360,-1.72341e-06,-1.7707e-05,-0.000490125,-7.85169e-05,19.44,480.0,29.1571,200.0,480.0,NaN,Y +MidNite Solar Inc: MN 15-12KW-AIO {240V},240,53.8737,10135,10496.5,360,-1.72341e-06,-1.7707e-05,-0.000490125,-7.85169e-05,19.44,480.0,29.1571,200.0,480.0,2025-10-01 00:00:00,Y +NEXTRACKER LLC: NXPCS1670K-HUD {800V},800,3676.36,1673400,1.70565e+06,1350,-6.09441e-09,2.1882e-06,0.000375315,0.000123176,223.1,1500.0,1263.45,1200.0,1500.0,NaN,Y +NEXTRACKER LLC: NXPCS3340K-HUD {800V},800,7431.25,3347800,3.40899e+06,1350,-3.23937e-09,1.91598e-06,0.000220482,-7.56062e-05,443.65,1500.0,2525.18,1200.0,1500.0,NaN,Y +NEXTRACKER LLC: NXPCS5000K-HUD {800V},800,11405.7,5004900,5.0946e+06,1350,-2.26284e-09,1.88118e-06,0.000202146,-9.82946e-05,638.04,1500.0,3773.78,1200.0,1500.0,NaN,Y +NEXTRACKER LLC: NXPCS800K-HUD {800V},800,2132.44,801420,818063,1350,-1.55416e-08,1.9047e-06,0.000277812,9.90744e-06,222.84,1500.0,605.973,1200.0,1500.0,NaN,Y +NeoVolta Inc: NV12KAC {240V},240,51.8788,12213.5,12699,360,-1.35354e-06,-3.77916e-05,0.00232624,0.00357488,13.2,430.0,35.275,200.0,430.0,NaN,Y +NeoVolta Inc: NV16KAC {240V},240,67.3944,16199,16830.4,360,-9.00267e-07,-1.12249e-05,0.00529221,0.00962936,20.47,430.0,46.7511,220.0,430.0,NaN,Y +NeoVolta Inc: NV7600 {208V},208,69.2487,7447.3,7678.92,370,-2.32485e-06,-7.35532e-06,-0.00100082,-0.00253433,13.4,425.0,20.7538,240.0,425.0,2022-12-01 00:00:00,Y +NeoVolta Inc: NV7600 {240V},240,74.7491,7657,7885.28,370,-2.613e-06,1.42063e-06,0.00134226,0.00420471,13.4,425.0,21.3116,240.0,425.0,2022-12-01 00:00:00,Y +Northern Electric & Power Co Ltd: BDH-10KSP-LB {208V},208,25.5059,8671,9017.65,360,-2.11397e-06,-6.13868e-05,0.00120895,0.000826696,16.22,500.0,25.049,220.0,500.0,NaN,Y +Northern Electric & Power Co Ltd: BDH-10KSP-LB {240V},240,32.1495,9991.4,10352.3,360,-2.45402e-06,-6.05137e-05,0.00063868,0.000160665,16.53,500.0,28.7563,220.0,500.0,NaN,Y +Northern Electric & Power Co Ltd: BDH-12KSP-LB {208V},208,27.1651,11517,11976.2,360,-1.32962e-06,-4.84192e-05,-0.000989249,0.00103384,16.25,500.0,33.2671,220.0,500.0,NaN,Y +Northern Electric & Power Co Ltd: BDH-12KSP-LB {240V},240,34.0443,11969,12386.8,360,-1.91393e-06,-5.08882e-05,0.00200138,0.00153515,16.48,500.0,34.4078,220.0,500.0,NaN,Y +Northern Electric & Power Co Ltd: BDH-8KSP-LB {208V},208,14.2252,6931.8,7208.05,360,-2.32723e-06,-6.99713e-05,-0.00258578,-0.000654873,16.26,500.0,20.0224,220.0,500.0,NaN,Y +Northern Electric & Power Co Ltd: BDH-8KSP-LB {240V},240,29.5038,7990,8292.87,360,-3.48629e-06,-6.23489e-05,0.00120186,0.000129784,16.56,500.0,23.0358,220.0,500.0,NaN,Y +Northern Electric & Power Co Ltd: BDM-1000-208A {208V},208,2.43571,819,848.406,35,-1.03016e-05,-6.97981e-05,0.0301684,0.0147193,0.1,55.0,24.2402,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1000-240A {240V},240,5.30786,934,969.643,35,-2.36577e-05,-6.50811e-05,0.00544217,-0.00640233,0.1,55.0,27.7041,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1200-208A {208V},208,4.93976,1070,1109.06,35,-1.22354e-05,3.95065e-05,0.0173145,0.0226927,0.1,55.0,31.6874,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1200-240A {240V},240,5.85075,1220,1265.68,35,-1.46757e-05,-1.61994e-05,0.00657746,-0.00186351,0.1,55.0,36.1623,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1200-LV {120V},120,7.22985,1193.5,1240.26,35,-2.1341e-05,-9.38384e-05,0.00847376,-0.0055602,13.6,55.0,35.436,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1600-208A {208V},208,8.65243,1331,1383.42,35,-1.95152e-05,2.00591e-05,0.00100825,0.000778324,0.2,55.0,39.5263,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1600-240A {240V},240,7.97682,1533,1595.54,35,-1.8388e-05,-0.000198067,-0.0212119,-0.0246897,0.3,55.0,45.5868,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-1600-LV {120V},120,9.32934,1597,1658.19,35,-1.53299e-05,-8.82531e-05,0.00876124,-0.00546632,9.7,55.0,47.3767,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-2000-208A {208V},208,10.1986,1663,1724.82,35,-1.27095e-05,6.51587e-06,0.00102041,-0.00310915,0.2,55.0,49.2804,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-2000-240A {240V},240,11.1999,1998,2072.51,35,-1.22895e-05,-9.10948e-05,0.0145251,-0.00116453,0.4,55.0,59.2144,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-300-208A {208V},208,1.18849,255,264.299,35,-5.48307e-05,-4.74225e-05,0.00241521,-0.00926436,1.2,55.0,7.55139,22.0,55.0,NaN,N +Northern Electric & Power Co Ltd: BDM-300-240A {240V},240,0.840228,289,299.427,35,-1.59878e-05,0.000109129,0.0292834,0.0841375,1.5,55.0,8.55506,22.0,55.0,NaN,N +Northern Electric & Power Co Ltd: BDM-300X2-208A {208V},208,3.8078,590,612.785,35,-4.14371e-05,4.80597e-05,0.00980479,0.00940281,0.2,55.0,17.5081,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-300X2-240A {240V},240,3.42554,576,598.218,35,-4.32365e-05,-0.000105914,0.00860319,-0.00559286,0.3,55.0,17.0919,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-350-208A {208V},208,1.80475,303,314.639,35,-7.37266e-05,-3.37761e-06,0.00724539,0.00560634,0.2,55.0,8.98968,22.0,55.0,NaN,N +Northern Electric & Power Co Ltd: BDM-350-240A {240V},240,2.03872,346,359.33,35,-7.16321e-05,-7.17456e-05,0.0106436,-0.0035963,0.3,55.0,10.2666,22.0,55.0,NaN,N +Northern Electric & Power Co Ltd: BDM-400-208A {208V},208,2.03301,343,356.088,35,-6.33807e-05,5.5941e-06,0.00761511,0.00673959,0.2,55.0,10.174,22.0,55.0,NaN,N +Northern Electric & Power Co Ltd: BDM-400-240A {240V},240,2.31239,398,413.381,35,-6.2579e-05,-7.7285e-05,0.0113614,-0.00347656,0.3,55.0,11.8109,22.0,55.0,NaN,N +Northern Electric & Power Co Ltd: BDM-550 {240V},240,3.6033,547,564.677,35,-1.98361e-05,-6.60706e-05,0.0031076,-0.000696418,0.134,55.0,16.1336,22.0,55.0,2023-05-11 00:00:00,N +Northern Electric & Power Co Ltd: BDM-650 {240V},240,3.29311,639,660.375,35,-1.53584e-05,-0.000136444,-0.00988803,-0.0230883,0.12,55.0,18.8679,22.0,55.0,2023-05-11 00:00:00,N +Northern Electric & Power Co Ltd: BDM-800-208A {208V},208,4.25828,707,733.937,35,-3.11823e-05,-2.17455e-06,0.00594045,0.00394605,0.1,55.0,20.9696,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-800-240A {240V},240,4.17119,772,801.73,35,-3.04044e-05,-8.89139e-05,-0.00391842,-0.0134169,0.1,55.0,22.9066,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: BDM-800-277A {277V},277,4.91972,798.72,829.325,35,-3.2581e-05,-0.000102461,0.0166272,0.00246503,0.5,55.0,23.695,22.0,55.0,2025-11-12 00:00:00,N +Northern Electric & Power Co Ltd: Neptune100K {480V},480,83.3343,99368,101480,730,-9.89649e-08,-2.16309e-05,-0.00421283,-0.000696956,2.0,850.0,139.013,550.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune25K {480V},480,15.3349,24888,25299.4,720,-1.95445e-07,-2.40865e-06,-0.00269824,-0.0027612,3.2724,850.0,35.138,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune30K {480V},480,36.132,29883,30405,720,-2.67085e-07,-2.82587e-06,-0.000846519,-0.000952389,3.2724,850.0,42.2291,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune30K-LV {208V},208,84.9098,29878,31000.4,580,-7.9747e-07,3.01359e-06,0.000167207,-0.000164951,1.394,680.0,53.449,340.0,680.0,NaN,N +Northern Electric & Power Co Ltd: Neptune33K {480V},480,23.6289,32865,33414.1,720,-1.84907e-07,-9.43334e-07,0.000577347,0.000401846,3.2724,850.0,46.4084,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune36K {480V},480,38.3233,35866,36520.8,720,-2.71062e-07,1.95129e-06,0.000864189,0.000780439,3.2724,850.0,50.7234,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune40K {480V},480,107.802,39841,40644.3,720,-4.54891e-07,1.07183e-05,0.000306405,0.00129958,3.2724,850.0,56.4504,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune50K {480V},480,104.275,49848,50714.8,720,-2.255e-07,-6.55568e-06,0.000373405,-0.00106045,3.2724,850.0,70.4372,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune60K {480V},480,121.037,59898,60956.2,720,-1.91613e-07,-1.90255e-06,0.000811883,8.54779e-05,3.1623,850.0,84.6614,580.0,850.0,NaN,N +Northern Electric & Power Co Ltd: Neptune75K {480V},480,100.984,74574,75961.2,730,-1.00224e-07,-1.84021e-05,-0.00194833,-0.00193716,2.0,850.0,104.056,550.0,850.0,NaN,N +ONE SUN MEXICO SA DE CV: 1S480-10k {480V},480,63.8968,9975,10171.9,750,-1.23006e-06,-1.83212e-05,0.000593869,-0.000584562,8.3,850.0,13.5625,450.0,850.0,NaN,N +OutBack Power: FXR3048A {120V},120,61.762,2560,2809.78,52,-1.95124e-05,0.000461825,0.0178642,-0.0207189,0.768,60.0,54.0342,40.0,60.0,2018-10-15 00:00:00,N +OutBack Power: GS4048A {240V},240,63.1602,3600,3846.93,48,-9.45827e-06,0.0018166,0.000159818,-0.0295234,0.1,56.0,80.1444,44.0,56.0,2020-12-01 00:00:00,N +OutBack Power: GS8048A {240V},240,57.4763,7200,8840.85,48,-2.10264e-05,-0.00181655,0.0240829,-0.016929,0.1,56.0,184.184,44.0,56.0,2020-12-01 00:00:00,N +OutBack Power: OGHI8048A {240V},240,114.374,7638,8448.26,48,-1.26428e-05,-0.00368536,-0.00704019,-0.0553994,146.4,52.0,176.005,44.0,52.0,2023-10-11 00:00:00,N +OutBack Power: PHXL480-10k {480V},480,63.8968,9975,10171.9,750,-1.23006e-06,-1.83212e-05,0.000593869,-0.000584562,8.3,850.0,13.5625,450.0,850.0,NaN,N +OutBack Power: SBX5048-120/240 {240V},240,67.803,4985,5278.14,420,-5.33954e-06,-3.22034e-05,0.000168779,-0.000980087,24.85,550.0,12.567,250.0,550.0,2021-03-11 00:00:00,Y +OutBack Power: VFXR3524A {120V},120,45.6609,2960,3343,24,-2.94955e-05,0.00161938,0.0706647,-0.0327723,0.888,28.0,139.292,22.0,28.0,2018-10-15 00:00:00,N +OutBack Power: VFXR3648A {120V},120,63.1471,3037,3385,51.2,-2.41793e-05,0.00153134,0.0274379,0.000288753,0.9111,60.0,66.1133,40.0,60.0,2018-10-15 00:00:00,N +Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {208V},208,54.3475,10186,10560.2,360,-1.71758e-06,-1.83118e-05,-0.000733476,-0.000439537,18.0,480.0,29.3338,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 10KHS/LV {240V},240,54.2141,10147,10509,360,-1.73767e-06,-1.81949e-05,-0.000673176,-0.000317833,18.0,480.0,29.1916,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {208V},208,54.056,10186,10559.8,360,-1.70398e-06,-1.83483e-05,-0.000763056,-0.00046152,16.94,480.0,29.3328,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 11K4HS/LV {240V},240,54.222,10140,10501.5,360,-1.72665e-06,-1.82761e-05,-0.000567918,-0.00026723,16.67,480.0,29.1709,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 5KHS/LV {208V},208,25.8481,5020,5195.39,360,-2.34121e-06,-3.28822e-05,-0.000773753,-0.00227295,15.0,480.0,14.4317,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 5KHS/LV {240V},240,25.4303,5040,5196.39,360,-1.76159e-06,-4.08294e-05,-0.000662743,-0.00438374,15.0,480.0,14.4344,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 6KHS/LV {208V},208,39.3472,6124,6337.1,360,-2.27837e-06,-2.94606e-05,-0.000829423,-0.000529414,19.2,480.0,17.6031,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 6KHS/LV {240V},240,39.6167,6149,6335.21,360,-1.56475e-06,-3.58904e-05,-0.000469452,-0.000730717,19.2,480.0,17.5978,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 7K6HS-T2/LV {208V},208,41.0561,7648,7919.97,360,-2.25575e-06,-1.9822e-05,-0.000763518,-0.000587419,15.0,480.0,21.9999,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 7K6HS-T2/LV {240V},240,53.0573,7647,7921.64,360,-2.83516e-06,-1.80857e-05,-0.00030204,-8.8294e-05,15.0,480.0,22.0045,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 7K6HS/LV {208V},208,41.0561,7648,7919.97,360,-2.25575e-06,-1.9822e-05,-0.000763518,-0.000587419,15.0,480.0,21.9999,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 7K6HS/LV {240V},240,53.0573,7647,7921.64,360,-2.83516e-06,-1.80857e-05,-0.00030204,-8.8294e-05,15.0,480.0,22.0045,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 8KHS/LV {208V},208,43.6503,8060,8356.75,360,-2.19669e-06,-1.82578e-05,-0.00067304,-0.00032298,17.78,480.0,23.2132,200.0,480.0,2026-05-21 00:00:00,Y +Oxford Intelligent Energy Co Ltd: OE 8KHS/LV {240V},240,43.5443,8047,8334.67,360,-2.21153e-06,-1.82488e-05,-0.00066946,-0.000325811,15.0,480.0,23.1519,200.0,480.0,2026-05-21 00:00:00,Y +PANASONIC CORPORATION OF NORTH AMERICA: EVHB-I7 {240V},240,20.0286,7608.19,7822.18,365.5,-1.72072e-06,-3.59271e-05,-0.000114689,-0.00169219,7.3,498.4,21.4013,234.1,498.4,2025-02-03 00:00:00,Y +POMCube Inc: PNZ-10K1N2-NA0 {240V},240,4.7171,9920,10509.4,360,7.69273e-07,-4.64726e-05,-0.0267633,0.00781544,21.92,530.0,29.1928,250.0,530.0,2024-02-21 00:00:00,Y +POWER ELECTRONICS: FP3151K {660V},660,11195.9,3145170,3.18984e+06,1024,-3.40802e-09,2.13445e-06,0.0005655,0.000601807,685.0,1200.0,3115.08,849.0,1200.0,NaN,N +POWER ELECTRONICS: FS2865K {600V},600,14023.7,2858630,2.91901e+06,1024,-5.29197e-09,2.51259e-06,0.000541503,0.000692587,623.5,1200.0,2850.59,849.0,1200.0,NaN,N +POWER ELECTRONICS: FS3820K {600V},600,17065.8,3825800,3.90921e+06,1026,-2.46382e-09,-2.19544e-06,0.000610883,-0.000155083,623.5,1200.0,3810.15,851.0,1200.0,NaN,N +PhaseGreen Technology Inc: PhG-P10K0LNA-M {240V},240,51.9471,10177,10475.8,360,-1.26046e-06,-2.00269e-05,-4.72702e-05,-0.000721728,33.64,430.0,29.0994,280.0,430.0,2026-03-11 00:00:00,Y +PhaseGreen Technology Inc: PhG-P5K0LNA-M {240V},240,29.3587,5089.7,5247.58,360,-3.6512e-06,-1.512e-05,0.000125821,0.000551915,22.6,430.0,14.5766,180.0,430.0,2026-03-11 00:00:00,Y +PhaseGreen Technology Inc: PhG-P6K0LNA-M {240V},240,33.6679,6117,6297.73,360,-2.58712e-06,-2.03092e-05,0.000191477,-0.0002564,22.99,430.0,17.4937,200.0,430.0,2026-03-11 00:00:00,Y +PhaseGreen Technology Inc: PhG-P7K6LNA-M {240V},240,37.4864,7765,7993.33,360,-1.60481e-06,-2.20802e-05,-0.000935129,-0.00139184,30.71,430.0,22.2037,220.0,430.0,2026-03-11 00:00:00,Y +PhaseGreen Technology Inc: PhG-P8K0LNA-M {240V},240,65.6455,8084,8326.69,360,-2.93482e-06,-6.00257e-06,-0.000923485,-0.00173197,17.4,430.0,23.1297,250.0,430.0,2026-03-11 00:00:00,Y +Pika Energy: X11402 {208V},208,20.5129,11187,11534.1,400,-1.22287e-06,6.87907e-05,0.0175372,0.00197184,0.13,420.0,28.8353,390.0,420.0,NaN,Y +Pika Energy: X11403 {208V},208,20.5466,11180,11526.9,400,-1.22558e-06,6.88372e-05,0.0175244,0.00198992,0.13,420.0,28.8173,390.0,420.0,2018-10-15 00:00:00,N +Pika Energy: X7601 {240V},240,67.1917,7587,7825.52,400,-2.74869e-06,3.71992e-05,0.0033086,-0.00446481,1.29,420.0,19.5638,390.0,420.0,2018-10-15 00:00:00,N +Pika Energy: X7602 {240V},240,66.92,7587,7823.26,400,-2.67644e-06,4.66929e-05,0.00321561,-0.00397886,1.29,420.0,19.5582,390.0,420.0,NaN,Y +Pika Energy: X7603 {240V},240,67.1917,7585,7823.42,400,-2.74869e-06,3.72333e-05,0.0033086,-0.00446481,1.29,420.0,19.5586,390.0,420.0,2018-10-15 00:00:00,N +PointGuard Energy Inc: PG Controller 114 {240V},240,19.0293,11460.1,11844.3,360,-1.07228e-06,-7.43687e-06,0.00054788,-0.000215638,3.3,480.0,32.9008,270.0,480.0,NaN,Y +PointGuard Energy Inc: PG Controller 38 {240V},240,21.0793,3843,3952.35,360,-1.95113e-06,-6.34335e-06,0.000468287,-0.000199437,3.26,480.0,10.9787,270.0,480.0,NaN,Y +PointGuard Energy Inc: PG Controller 48 {240V},240,20.636,4808,4948.52,360,-1.86359e-06,-7.25265e-06,0.000427717,-0.000219266,3.32,480.0,13.7459,270.0,480.0,NaN,Y +PointGuard Energy Inc: PG Controller 57 {240V},240,20.3544,5776,5950.03,360,-1.6812e-06,-6.23562e-06,0.000753848,0.00028414,3.37,480.0,16.5279,270.0,480.0,NaN,Y +PointGuard Energy Inc: PG Controller 76 {240V},240,18.146,7689,7934.57,360,-1.36321e-06,-6.66298e-06,0.000569797,3.35698e-05,3.36,480.0,22.0405,270.0,480.0,NaN,Y +PointGuard Energy Inc: PG Controller 96 {240V},240,14.3898,9653,9976.67,360,-1.06514e-06,-1.288e-05,-0.000159282,-0.00134099,3.35,480.0,27.713,270.0,480.0,NaN,Y +Power Center: D1500-M4 {240V},240,2.30443,1439,1492.19,42,-2.34848e-06,-0.000354019,-0.0918936,-0.356898,0.11,48.0,35.5283,36.0,48.0,2023-10-23 00:00:00,N +Power Center: D350-M1 {240V},240,0.675628,349.5,362.544,40,-1.46101e-05,-0.000283318,-0.0323591,-0.154329,0.105,48.0,9.06359,33.0,48.0,2023-05-01 00:00:00,N +Power Center: D350-M1A-208A {208V},208,1.80475,303,314.639,35,-7.37266e-05,-3.37761e-06,0.00724539,0.00560634,0.2,55.0,8.98968,22.0,55.0,NaN,N +Power Center: D350-M1A-240A {240V},240,2.03872,346,359.33,35,-7.16321e-05,-7.17456e-05,0.0106436,-0.0035963,0.3,55.0,10.2666,22.0,55.0,NaN,N +Power Center: D400-M1A-208A {208V},208,2.03301,343,356.088,35,-6.33807e-05,5.5941e-06,0.00761511,0.00673959,0.2,55.0,10.174,22.0,55.0,NaN,N +Power Center: D400-M1A-240A {240V},240,2.31239,398,413.381,35,-6.2579e-05,-7.7285e-05,0.0113614,-0.00347656,0.3,55.0,11.8109,22.0,55.0,NaN,N +Power Center: D600-M2A-208A {208V},208,3.8078,590,612.785,35,-4.14371e-05,4.80597e-05,0.00980479,0.00940281,0.2,55.0,17.5081,22.0,55.0,NaN,N +Power Center: D600-M2A-240A {240V},240,3.42554,576,598.218,35,-4.32365e-05,-0.000105914,0.00860319,-0.00559286,0.3,55.0,17.0919,22.0,55.0,NaN,N +Power Center: D700-M2 {240V},240,1.1184,697,722.571,42,-4.53834e-06,-0.00028638,-0.0634212,-0.271915,0.11,48.0,17.2041,33.0,48.0,2023-05-01 00:00:00,N +Power Center: D800-M2A-208A {208V},208,4.25828,707,733.937,35,-3.11823e-05,-2.17456e-06,0.00594045,0.00394605,0.1,55.0,20.9696,22.0,55.0,NaN,N +Power Center: D800-M2A-240A {240V},240,4.17119,772,801.73,35,-3.04044e-05,-8.89139e-05,-0.00391842,-0.0134169,0.1,55.0,22.9066,22.0,55.0,NaN,N +Power Center: Essential Hybrid 5 {120V},120,15.6506,4787.1,5008.18,312.5,-5.70296e-06,6.79119e-06,0.00105549,0.000766521,11.7,425.0,16.0262,200.0,425.0,NaN,Y +Power Center: Essential Hybrid 5 {240V},240,26.6709,7970.3,8338.57,312.5,-3.50061e-06,1.20283e-05,-0.000808149,-0.000257411,19.3,425.0,26.6834,200.0,425.0,NaN,Y +Power Center: Max Hybrid 15 {208V},208,70.9245,13010,13511.4,320,-1.95422e-06,-2.30337e-07,-5.48816e-05,9.23267e-05,21.2,425.0,42.223,200.0,425.0,2024-11-01 00:00:00,Y +Power Center: Max Hybrid 15 {240V},240,83.1383,15040,15606.1,320,-1.70709e-06,2.22468e-07,8.144e-05,0.000201634,21.2,425.0,48.769,200.0,425.0,2024-11-01 00:00:00,Y +Power Center: Max Hybrid 30 (208V) {120V},120,95.5145,30025,31420.4,385,-9.13777e-07,8.98357e-06,0.00018143,0.000242698,31.9,500.0,81.6114,270.0,500.0,2025-03-21 00:00:00,Y +Power Center: Max Hybrid 60 {277V},277,285.708,60050,61997.1,695,-5.47422e-07,3.60259e-06,-0.000145593,-0.000123233,5.29,850.0,89.2045,540.0,850.0,2025-03-21 00:00:00,Y +Power Electronics: FP3000K3 {600V},600,11759.9,3116969,3.181e+06,940,-4.40082e-09,2.28821e-06,4.39282e-05,5.3316e-05,442.59,1200.0,3384.04,849.0,1200.0,NaN,N +Power Electronics: FP3510M2 {34500V},34500,16667.5,3662494,3.76449e+06,1000,-4.59413e-09,1.17168e-06,-0.000296242,-0.000344233,7640.0,1200.0,3764.49,934.0,1200.0,NaN,N +Power Electronics: FP3510M3 {34500V},34500,21560.3,3630064,3.74285e+06,1000,-7.66039e-09,-2.70799e-06,-0.000294192,-0.00061319,7640.0,1200.0,3742.85,934.0,1200.0,NaN,N +Power Electronics: FP4200M {34500V},34500,28398.8,4198710,4.28755e+06,1067,-3.40344e-09,5.13391e-06,-6.68826e-05,-0.000824793,7033.0,1200.0,4018.33,934.0,1200.0,NaN,N +Power Electronics: FS1050CU15 {565V},565,7801.17,1163500,1.19453e+06,900,-1.15275e-08,3.19949e-06,5.2446e-05,0.000458595,338.51,1200.0,1327.25,800.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1100CU15 {600V},600,7821.62,1209250,1.23851e+06,940,-8.12332e-09,5.02375e-06,0.000121484,0.00107205,347.22,1200.0,1317.56,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1100CU15O3 {600V},600,3357.44,1176440,1.20128e+06,940,-5.04709e-09,2.45623e-06,0.000152654,0.000663529,358.91,1200.0,1277.96,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1200CU15 {645V},645,7901.11,1300900,1.33218e+06,980,-8.70514e-09,2.01096e-06,0.000104016,0.000351258,348.45,1200.0,1359.37,913.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1275CU15 {690V},690,12939.8,1389080,1.42152e+06,1030,-1.05483e-08,6.79439e-06,-0.000111134,0.000556775,353.05,1200.0,1380.12,976.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1400CU15 {565V},565,8330.42,1517090,1.55511e+06,900,-8.71904e-09,1.89602e-06,-0.000166385,-0.00020132,359.56,1200.0,1727.9,800.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1475CU15 {600V},600,8754.34,1610370,1.65003e+06,940,-9.25013e-09,2.96259e-06,-8.739e-05,-2.82297e-05,368.71,1200.0,1755.36,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1500CU15O3 {600V},600,3696.71,1594720,1.62971e+06,940,-4.99138e-09,1.89553e-06,0.000360016,0.000411768,379.71,1200.0,1733.73,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1600CU15 {645V},645,9016.75,1734810,1.77468e+06,980,-7.73212e-09,2.56323e-06,-0.000260308,-0.000398813,373.96,1200.0,1810.9,913.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1700CU15 {690V},690,9487.63,1850630,1.89041e+06,1030,-7.37074e-09,4.45029e-06,0.000142521,0.000279927,368.51,1200.0,1835.35,976.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1750CU15 {565V},565,10200.4,1896530,1.94236e+06,900,-7.4623e-09,4.36975e-06,0.000142243,0.000355082,378.47,1200.0,2158.18,800.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1850CU15 {600V},600,10239.9,2020960,2.06764e+06,940,-6.52374e-09,5.09665e-06,0.000185785,0.000606202,388.77,1200.0,2199.62,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS1850CU15O3 {600V},600,4621.43,1974290,2.01746e+06,940,-4.27048e-09,2.36787e-06,-9.77215e-05,9.25089e-05,397.3,1200.0,2146.23,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2000CU15 {645V},645,10504.8,2162420,2.20973e+06,980,-5.72271e-09,2.64457e-06,-5.23288e-05,-6.19467e-05,388.97,1200.0,2254.83,913.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2000K {600V},600,8719.84,2103416,2.15005e+06,940,-8.02696e-09,3.51397e-06,0.000145863,0.000486244,442.59,1200.0,2287.29,849.0,1200.0,NaN,N +Power Electronics: FS2000M {34000V},34500,13704.5,2178068,2.23378e+06,940,-4.85995e-09,8.8593e-07,3.54256e-05,-3.29175e-05,5970.0,1200.0,2376.36,849.0,1200.0,NaN,N +Power Electronics: FS2100CU15 {565V},565,9954.75,2275890,2.33057e+06,900,-6.13475e-09,2.25198e-06,-8.42575e-05,-0.000202307,398.85,1200.0,2589.52,800.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2125CU15 {690V},690,10246.2,2306410,2.35481e+06,1030,-5.29284e-09,7.76732e-06,0.000413512,0.000967189,390.63,1200.0,2286.22,976.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2125K {600V},600,9363.71,2201520,2.24701e+06,940,-6.01944e-09,4.09162e-06,0.000132892,0.00032905,302.3,1200.0,2390.44,849.0,1200.0,NaN,N +Power Electronics: FS2150CU15 {645V},645,10531.9,2558480,2.61445e+06,980,-5.09124e-09,2.31444e-06,0.000337143,0.000515722,409.99,1200.0,2667.81,913.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2180K {615V},615,9561.79,2259500,2.30442e+06,950,-5.47015e-09,2.49531e-06,8.77785e-05,0.000135621,302.3,1200.0,2425.71,870.0,1200.0,NaN,N +Power Electronics: FS2225CU15 {600V},600,10855.1,2417080,2.47237e+06,940,-6.00608e-09,2.24623e-06,4.77479e-05,-1.71489e-06,403.32,1200.0,2630.18,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2250CU15O3 {600V},600,5201.1,2420370,2.47431e+06,940,-4.1345e-09,1.53629e-06,0.000230893,-1.74738e-05,416.47,1200.0,2632.25,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2300CU15 {690V},690,10720.4,2759490,2.81693e+06,1030,-4.30581e-09,3.95083e-06,0.000152205,0.000407866,408.67,1200.0,2734.89,976.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2400CU15 {645V},645,10017.5,2583760,2.64032e+06,980,-4.80731e-09,2.92089e-06,0.000131134,0.000130316,407.44,1200.0,2694.2,913.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2450CU15 {565V},565,10797.8,2664070,2.72774e+06,900,-5.10808e-09,1.94282e-06,8.20481e-06,-2.22494e-05,417.35,1200.0,3030.82,800.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2550CU15 {690V},690,10929,2759390,2.81925e+06,1030,-4.98053e-09,-1.06563e-06,-0.000423406,-0.00109756,408.29,1200.0,2737.14,976.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2600CU15 {600V},600,11333.4,2821840,2.88677e+06,940,-5.03599e-09,1.69476e-06,0.000163871,2.06454e-05,423.67,1200.0,3071.03,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2600CU15O3 {600V},600,5125.5,2770200,2.83097e+06,940,-3.19604e-09,2.31156e-06,0.000100841,0.000131746,433.54,1200.0,3011.67,849.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2800CU15 {645V},645,11199.9,3024910,3.09099e+06,940,-4.03043e-09,2.37155e-06,5.65554e-05,-2.59337e-05,427.54,1200.0,3288.29,913.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS2840M {34000V},34500,13930.9,2844700,2.91484e+06,940,-3.34574e-09,2.0013e-06,0.00019434,0.000572214,5970.0,1200.0,3100.89,849.0,1200.0,NaN,N +Power Electronics: FS3000CU15 {690V},690,11386.9,3201170,3.26489e+06,1030,-3.12354e-09,8.34491e-06,0.00071146,0.00220614,426.4,1200.0,3169.79,976.0,1200.0,2018-10-15 00:00:00,N +Power Electronics: FS3000K {600V},600,10422.5,3121310,3.18862e+06,940,-4.69574e-09,1.71662e-06,-5.81161e-05,-0.000139989,324.8,1200.0,3392.14,849.0,1200.0,NaN,N +Power Electronics: FS3000M {34000V},34500,14559.5,3109266,3.19589e+06,940,-5.2375e-09,9.02061e-07,-7.96816e-07,2.07388e-05,6056.0,1200.0,3399.88,849.0,1200.0,NaN,N +Power Electronics: FS3001M {34000V},34500,14748.1,3017848,3.09475e+06,940,-3.92779e-09,1.12722e-06,0.000143117,0.000216508,6084.0,1200.0,3292.29,849.0,1200.0,NaN,N +Power Electronics: FS3150K {630V},630,7999.61,3279870,3.35985e+06,970,-3.53407e-09,1.29783e-06,0.000819427,0.000692266,324.8,1200.0,3463.76,891.0,1200.0,NaN,N +Power Electronics: FS3150M {34000V},34500,15561.8,3307980,3.39925e+06,970,-5.01724e-09,6.80404e-07,2.65271e-05,-7.77301e-05,6880.0,1200.0,3504.38,891.0,1200.0,NaN,N +Power Electronics: FS3190K {600V},630,11417.2,3303820,3.37333e+06,940,-4.21866e-09,1.32019e-06,-5.54396e-05,-0.000126116,324.8,1200.0,3588.65,849.0,1200.0,NaN,N +Power Electronics: FS3225M {34000V},34500,20297.3,3367326,3.47294e+06,980,-8.29857e-09,-3.38838e-06,-0.000258675,-0.000558753,7640.0,1200.0,3543.82,913.0,1200.0,NaN,N +Power Electronics: FS3270K {615V},615,12815.9,3376294,3.45821e+06,950,-5.29504e-09,1.69159e-06,2.69528e-05,-1.77274e-05,332.9,1200.0,3640.22,870.0,1200.0,NaN,N +Power Electronics: FS4010K {630V},630,20687.4,4058537,4.14865e+06,1046,-3.0997e-09,-8.36653e-08,0.00060661,-0.000504465,623.5,1200.0,3966.21,891.0,1200.0,NaN,N +Power Electronics: FS4200M {34500V},34500,28478.1,4198715,4.28785e+06,1067,-3.44472e-09,5.50473e-06,-6.71043e-05,-0.00076459,7033.0,1200.0,4018.61,934.0,1200.0,NaN,N +Princeton Power Systems Inc: GTIB-480-125XXXXXX-G15 {480V},480,1038.79,124964,129454,710,-1.38398e-07,-3.7363e-05,-0.0015955,-0.00191736,68.0,830.0,182.329,350.0,830.0,NaN,Y +Princeton Power Systems Inc: GTIB-480-125XXXXXX-W-G15 {480V},480,1412.99,124964,132204,710,-3.00261e-07,-3.74205e-05,-0.00118509,-0.000823115,68.0,830.0,186.202,350.0,830.0,NaN,Y +Princeton Power Systems Inc: GTIB-480-30-WZZZZZZ-G13 {480V},480,319.197,29444,31735.3,750,-1.49339e-06,-3.4239e-05,-0.00092808,-0.000933386,35.14,830.0,42.3138,540.0,830.0,NaN,Y +Princeton Power Systems Inc: GTIB-480-30-ZZZZZZ-G13 {480V},480,184.707,29956,30783.2,750,-1.73046e-07,-2.06332e-05,-0.000448758,-0.00591363,46.3,830.0,41.0443,540.0,830.0,NaN,Y +Qcells North America: QHOME+ AC-G1-60 {240V},240,77.7696,5732,6025.25,430,-2.60948e-06,-1.16235e-05,-0.000183991,-0.00125975,25.0,500.0,14.0122,360.0,500.0,2024-10-11 00:00:00,N +Qcells North America: QHOME+ AC-G1-70 {240V},240,86.2952,6680,7047.85,390,-5.25849e-06,-1.08839e-05,0.000700888,-0.00052983,25.0,500.0,18.0714,280.0,500.0,2024-10-11 00:00:00,N +Qcells North America: QHOME+ AC-G1-76 {240V},240,48.8966,7832,8223.37,375,-2.98068e-06,-4.56175e-05,-0.00242048,-0.00359598,49.5,430.0,21.929,320.0,430.0,2024-10-11 00:00:00,N +Qcells North America: QHOME+ AC-G1-86 {240V},240,47.4759,8613,9035.99,396.5,-2.61282e-06,-4.21776e-05,0.00177193,-0.00158556,42.0,430.0,22.7894,363.0,430.0,2024-10-11 00:00:00,N +Qcells North America: QHOME+ HYB-G1-60 {240V},240,76.4939,5570,5867.43,335,-2.70981e-06,-4.25927e-05,0.000676665,-0.0022977,25.0,425.0,17.5147,240.0,425.0,2024-10-11 00:00:00,Y +Qcells North America: QHOME+ HYB-G1-70 {240V},240,76.9232,6666,7018.43,360,-2.61451e-06,-4.12138e-05,0.00105761,-0.00230985,25.0,425.0,19.4956,290.0,425.0,2024-10-11 00:00:00,Y +Qcells North America: QHOME+ HYB-G1-76 {240V},240,49.2438,7642,7986.08,402,-2.27199e-06,-4.04422e-05,-0.00127208,-0.000949817,44.0,500.0,19.8659,304.0,500.0,2024-10-11 00:00:00,Y +Qcells North America: QHOME+ HYB-G1-86 {240V},240,47.3466,8604,9013.82,379,-2.55859e-06,-4.0658e-05,-0.000601146,-0.000323469,40.0,500.0,23.7832,258.0,500.0,2024-10-11 00:00:00,Y +Qcells North America: QMI349B-G1 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-02-21 00:00:00,N +Qcells North America: QMI380C-G2 {208V},208,1.66811,330.2,341.442,32.5,-6.46621e-05,-0.000120532,-0.0165965,-0.0444015,0.015,41.0,10.5059,29.5,41.0,NaN,N +Qcells North America: QMI380C-G2 {240V},240,2.00541,378.9,390.539,32.5,-5.38532e-05,-0.000131031,-0.0189832,-0.0444475,0.029,40.0,12.0166,30.0,40.0,NaN,N +Qcells North America: QMICRO380C-G2 {208V},208,1.66811,330.2,341.442,32.5,-6.46621e-05,-0.000120532,-0.0165965,-0.0444015,0.015,41.0,10.5059,29.5,41.0,NaN,N +Qcells North America: QMICRO380C-G2 {240V},240,2.00541,378.9,390.539,32.5,-5.38532e-05,-0.000131031,-0.0189832,-0.0444475,0.029,40.0,12.0166,30.0,40.0,NaN,N +Qcells North America: QPEAK DUO BLK ML-G10C1+/AC 395 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2026-05-01 00:00:00,N +Qcells North America: QPEAK DUO BLK ML-G10C1+/AC 400 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2026-05-01 00:00:00,N +Qcells North America: QPEAK DUO BLK ML-G10C1+/AC 405 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2026-05-01 00:00:00,N +Qcells North America: QPEAK DUO BLK ML-G10C1+/AC 410 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2026-05-01 00:00:00,N +Qcells North America: QPEAK DUO BLK ML-G10C1+/AC 415 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2026-05-01 00:00:00,N +Qcells North America: QPEAK DUO BLK-G10+/AC 360 {240V},240,1.8874,290,299.066,36,-6.58297e-05,-0.000273767,0.0188955,-0.0278326,0.025,45.0,8.30738,27.0,45.0,2024-04-02 00:00:00,N +Qcells North America: QPEAK DUO BLK-G10+/AC 365 {240V},240,1.8874,290,299.066,36,-6.58297e-05,-0.000273767,0.0188955,-0.0278326,0.025,45.0,8.30738,27.0,45.0,2024-04-02 00:00:00,N +Qcells North America: QPEAK DUO BLK-G10+/AC 370 {240V},240,1.8874,290,299.066,36,-6.58297e-05,-0.000273767,0.0188955,-0.0278326,0.025,45.0,8.30738,27.0,45.0,2024-04-02 00:00:00,N +Qcells North America: QPEAK DUO BLK-G6+/AC 340 {240V},240,1.8874,290,299.066,36,-6.58297e-05,-0.000273767,0.0188955,-0.0278326,0.025,45.0,8.30738,27.0,45.0,2024-04-02 00:00:00,N +Qcells North America: QPEAK DUO BLK-G6+/AC 345 {240V},240,1.8874,290,299.066,36,-6.58297e-05,-0.000273767,0.0188955,-0.0278326,0.025,45.0,8.30738,27.0,45.0,2024-04-02 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 405 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-04-11 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 410 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-04-11 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 415 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 420 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 425 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 430 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 435 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 440 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2+/AC 445 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 415 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 420 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 425 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 430 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 435 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 440 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2C1+/AC 445 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 405 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 410 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 415 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 420 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 425 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 430 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 435 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2F1+/AC 440 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2H1+/AC 405 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2H1+/AC 410 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QTRON BLK M-G2H1+/AC 415 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2H1+/AC 420 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2H1+/AC 425 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2H1+/AC 430 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2H1+/AC 435 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2H1+/AC 440 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,2025-12-22 00:00:00,N +Qcells North America: QTRON BLK M-G2H1+/AC 445 {240V},240,2.43341,349,361.249,33.5,-7.48216e-05,-0.000228355,-0.00809111,-0.0363271,0.27,40.0,10.7835,31.0,40.0,NaN,N +Qcells North America: QVOLT A38SX {240V},240,40.8341,3810,3980.85,262.8,-4.72445e-06,-0.000100415,0.00125403,-0.00149334,1.2,450.0,15.1478,75.6,450.0,2024-06-03 00:00:00,N +Qcells North America: QVOLT A50SX {240V},240,38.6311,5030,5231.34,275.5,-2.90079e-06,-7.56354e-05,0.00116534,-0.00160809,1.2,449.9,18.9885,100.4,449.9,2024-06-03 00:00:00,N +Qcells North America: QVOLT A60SX {240V},240,37.0267,6035,6267.02,285.1,-2.2864e-06,-6.63378e-05,0.000968099,-0.00215828,1.2,449.9,21.9818,121.1,449.9,2024-06-03 00:00:00,N +Qcells North America: QVOLT A76SX {240V},240,34.2555,7601,7887.41,300.1,-1.82032e-06,-5.83933e-05,0.000378563,-0.00227531,1.2,449.8,26.2826,149.7,449.8,2024-06-03 00:00:00,N +Qcells North America: QVOLT H38SX {240V},240,23.0534,3805,3915.44,337.9,-2.81602e-06,-3.68728e-05,0.00102784,0.00044996,1.2,499.5,11.5876,175.4,499.5,2024-06-03 00:00:00,Y +Qcells North America: QVOLT H50SX {240V},240,17.7094,5003,5138.33,363.7,-1.73316e-06,-2.94407e-05,2.0865e-05,-0.000721874,1.2,499.9,14.1279,229.9,499.9,2024-06-03 00:00:00,Y +Qcells North America: QVOLT H60SX {240V},240,20.099,6017,6177.57,388.3,-1.77531e-06,-2.62162e-05,0.00103226,-0.000265801,1.2,498.7,15.9093,277.0,498.7,2024-06-03 00:00:00,Y +Qcells North America: QVOLT H76SX {240V},240,20.2157,7593,7806,365.5,-1.71961e-06,-3.5814e-05,-0.000137721,-0.00170275,1.2,498.4,21.357,234.1,498.4,2024-06-03 00:00:00,Y +RCT Power Energy Technology Corporation: Power Storage DC US-150 {208V},208,85.586,14947,15654.2,380,-1.23034e-06,-5.10847e-05,-0.00081342,-0.000385272,16.1,440.0,41.1953,220.0,440.0,NaN,Y +RCT Power Energy Technology Corporation: Power Storage DC US-150 {240V},240,89.3631,14947,15634.6,380,-1.13372e-06,-6.55579e-05,-0.00195821,-0.00049108,16.1,440.0,41.1436,220.0,440.0,NaN,Y +RCT Power Energy Technology Corporation: Power Storage DC US-80 PRO {208V},208,41.2034,7015,7244.95,360,-2.69339e-06,-4.13342e-05,-0.000193439,-0.000562648,0.3,420.0,20.1249,220.0,420.0,NaN,Y +RCT Power Energy Technology Corporation: Power Storage DC US-80 PRO {240V},240,38.6265,8032.2,8267.26,360,-2.14409e-06,-4.1133e-05,-0.000153539,-0.00107544,0.4025,420.0,22.9646,220.0,420.0,NaN,Y +RCT Power Energy Technology Corporation: Power Storage DC US-80 {208V},208,41.3127,7015,7245.09,360,-2.70641e-06,-4.13425e-05,-0.000204197,-0.000575843,0.3,420.0,20.1252,220.0,420.0,NaN,Y +RCT Power Energy Technology Corporation: Power Storage DC US-80 {240V},240,38.6265,8032.2,8267.26,360,-2.14409e-06,-4.1133e-05,-0.000153539,-0.00107544,0.4025,420.0,22.9646,220.0,420.0,NaN,Y +RNG International Inc: RIV4810HI-SPS {240V},240,51.9471,10177,10475.8,360,-1.26047e-06,-2.00269e-05,-4.72679e-05,-0.000721726,33.64,430.0,29.0994,280.0,430.0,2024-09-03 00:00:00,Y +RNG International Inc: RIV4850HI-SPS {240V},240,29.3587,5089.7,5247.58,360,-3.6512e-06,-1.512e-05,0.000125821,0.000551915,22.6,430.0,14.5766,180.0,430.0,2024-09-03 00:00:00,Y +RNG International Inc: RIV4860HI-SPS {240V},240,33.668,6117,6297.73,360,-2.58712e-06,-2.03092e-05,0.000191477,-0.000256399,22.99,430.0,17.4937,200.0,430.0,2024-09-03 00:00:00,Y +RNG International Inc: RIV4876HI-SPS {240V},240,37.4865,7765,7993.33,360,-1.60481e-06,-2.20802e-05,-0.000935126,-0.00139183,30.71,430.0,22.2037,220.0,430.0,2024-09-03 00:00:00,Y +RNG International Inc: RIV4880HI-SPS {240V},240,65.6455,8084,8326.69,360,-2.93482e-06,-6.00257e-06,-0.000923485,-0.00173197,17.4,430.0,23.1297,250.0,430.0,2024-09-03 00:00:00,Y +RelyEZ Energy Storage Technology Co Ltd: Sync Micro 550S {240V},240,11.7207,550,573.422,56,-1.61036e-05,-0.000258235,0.00187393,-0.0144308,0.03,76.0,10.2397,36.0,76.0,NaN,N +RelyEZ Energy Storage Technology Co Ltd: Sync Micro 660S {240V},240,11.9792,660,686.872,60,-1.81825e-05,-0.000335932,0.00177585,-0.0193753,0.03,76.0,11.4479,43.0,76.0,NaN,N +RelyEZ Energy Storage Technology Co Ltd: Sync Micro 760S {240V},240,11.9394,760,789.941,63,-1.64904e-05,-0.000364573,0.0038321,-0.00993032,0.04,76.0,12.5387,50.0,76.0,NaN,N +Rhombus Energy Solutions: BESI-50kW-480 {480V},480,1486.7,49350,51401.4,636,-7.28154e-07,-3.20534e-06,-0.000744008,-0.00264904,103.0,840.0,80.8199,550.0,840.0,2018-10-15 00:00:00,N +Rhombus Energy Solutions: BESS-50kW-480 {480V},480,1486.7,49350,51401.4,636,-7.28154e-07,-3.20534e-06,-0.000744008,-0.00264904,103.0,840.0,80.8199,550.0,840.0,2018-10-15 00:00:00,N +Rhombus Energy Solutions: RES-BESS60DP-480 {480V},480,1232.54,59789,64196.2,441,-3.8677e-07,2.72203e-05,0.000244864,-0.000315706,92.0,870.0,145.57,270.0,870.0,2022-02-11 00:00:00,Y +SHENZHEN CLOU ELECTRONICS CO LTD: CL215HX-IEC/UL {690V},690,598.435,236841,240655,1331,-3.97676e-08,6.36546e-06,0.000235292,-0.000188858,34.62,1500.0,180.808,1060.0,1500.0,NaN,N +SHENZHEN CLOU ELECTRONICS CO LTD: CL430HX-IEC/UL {690V},690,1439,473495,481092,1331,-2.30695e-08,5.78414e-06,0.000555191,0.000280436,72.52,1500.0,361.451,1060.0,1500.0,NaN,N +SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL10K-P2WB {240V},240,50.6752,10010.9,10362.7,380,-1.11564e-06,-6.61416e-05,-0.000452634,-0.00267001,10.12,480.0,27.2703,135.0,480.0,NaN,Y +SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL12K-P2WB {240V},240,47.5069,12014.5,12447.4,380,-1.2097e-06,-6.21825e-05,-0.00131058,-0.0021937,10.39,480.0,32.7563,161.0,480.0,NaN,Y +SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL15K-P2WB {240V},240,49.0214,15014.8,15596.5,380,-1.2472e-06,-5.40958e-05,-0.00144971,-0.00136986,10.08,480.0,41.0434,202.0,480.0,NaN,Y +SHENZHENMYSMARTENERGYELECTRICCO LTD: MY-HL8K-P2WB {240V},240,51.452,7981.39,8255.49,380,-1.52067e-06,-7.70681e-05,-0.000266767,-0.00307047,10.39,480.0,21.725,108.0,480.0,NaN,Y +SINENG ELECTRIC CO LTD: EH-0200-HA-M-US {690V},690,829.369,220432,225999,1199,-5.769e-08,8.89874e-06,0.00111707,-0.000236097,316.0,1346.0,188.49,1056.0,1346.0,NaN,N +SINENG ELECTRIC CO LTD: EH-1250-HB-UD-US {690V},690,2619.17,1.25074e+06,1.27567e+06,1250,-5.99463e-09,7.85228e-07,0.000411444,-8.06599e-05,204.94,1500.0,1020.54,1000.0,1500.0,NaN,N +SINENG ELECTRIC CO LTD: EH-1725-HA-UD-US {690V},690,8540.44,1.7267e+06,1.75612e+06,1250,-5.21565e-09,3.60538e-06,0.000624642,-0.000151315,157.41,1500.0,1404.89,1000.0,1500.0,NaN,N +SINENG ELECTRIC CO LTD: EH-2000-HA-UD-US {690V},690,10086.2,2.00382e+06,2.04172e+06,1250,-7.51339e-09,2.20616e-06,0.000537928,-0.000218698,159.36,1500.0,1633.38,1000.0,1500.0,NaN,N +SMA America: SB30-1SP-US-40 {208V},208,26.8854,3000,3105.92,365,-5.71444e-06,-3.33244e-05,0.00166095,0.000396299,5.36,480.0,8.50937,155.0,480.0,2019-02-15 00:00:00,N +SMA America: SB30-1SP-US-40 {240V},240,27.8492,3000,3094.34,365,-4.31643e-06,-3.94214e-05,0.00124032,0.00043257,5.39,480.0,8.47763,155.0,480.0,2019-02-15 00:00:00,N +SMA America: SB30-1SP-US-41 {208V},208,26.8463,3000,3105.96,365,-5.72275e-06,-3.3338e-05,0.00166095,0.000396299,5.36,480.0,8.50949,155.0,480.0,2020-01-21 00:00:00,N +SMA America: SB30-1SP-US-41 {240V},240,27.8175,3000,3094.39,365,-4.33347e-06,-3.94142e-05,0.00124054,0.000441293,5.39,480.0,8.47779,155.0,480.0,2020-01-21 00:00:00,N +SMA America: SB30-1TP-US-40 {208V},208,26.8854,3000,3105.92,365,-5.71444e-06,-3.33244e-05,0.00166095,0.000396299,5.36,480.0,8.50937,155.0,480.0,2019-02-15 00:00:00,N +SMA America: SB30-1TP-US-40 {240V},240,27.8492,3000,3094.34,365,-4.31643e-06,-3.94214e-05,0.00124032,0.00043257,5.39,480.0,8.47763,155.0,480.0,2019-02-15 00:00:00,N +SMA America: SB30-1TP-US-41 {208V},208,26.873,3000,3106.06,365,-5.73817e-06,-3.32288e-05,0.00165436,0.000384837,5.36,480.0,8.50976,155.0,480.0,2020-01-13 00:00:00,N +SMA America: SB30-1TP-US-41 {240V},240,27.8574,3000,3094.4,365,-4.35259e-06,-3.9381e-05,0.00123403,0.000433382,5.39,480.0,8.4778,155.0,480.0,2020-01-13 00:00:00,N +SMA America: SB38-1SP-US-40 {208V},208,26.8998,3600,3723.05,365,-4.1933e-06,-2.61432e-05,0.00161811,-0.000554213,5.36,480.0,10.2001,195.0,480.0,2019-02-15 00:00:00,N +SMA America: SB38-1SP-US-40 {240V},240,25.5465,3800,3914.75,365,-2.90207e-06,-4.02793e-05,0.00100374,-0.00208741,5.39,480.0,10.7253,195.0,480.0,2019-02-15 00:00:00,N +SMA America: SB38-1SP-US-41 {208V},208,26.8953,3604,3727.23,365,-4.19401e-06,-2.61718e-05,0.00161811,-0.000554207,5.36,480.0,10.2116,195.0,480.0,2020-01-21 00:00:00,N +SMA America: SB38-1SP-US-41 {240V},240,25.5394,3840,3956.18,365,-2.90287e-06,-4.06352e-05,0.00100374,-0.00208741,5.39,480.0,10.8389,195.0,480.0,2020-01-21 00:00:00,N +SMA America: SB38-1TP-US-40 {208V},208,26.8998,3600,3723.05,365,-4.1933e-06,-2.61432e-05,0.00161811,-0.000554213,5.36,480.0,10.2001,195.0,480.0,2019-02-15 00:00:00,N +SMA America: SB38-1TP-US-40 {240V},240,25.5465,3800,3914.75,365,-2.90207e-06,-4.02793e-05,0.00100374,-0.00208741,5.39,480.0,10.7253,195.0,480.0,2019-02-15 00:00:00,N +SMA America: SB38-1TP-US-41 {208V},208,23.8391,3604,3727.39,365,-3.94571e-06,-2.59185e-05,0.000776943,-0.00110384,5.36,480.0,10.212,195.0,480.0,2020-01-13 00:00:00,N +SMA America: SB38-1TP-US-41 {240V},240,25.5155,3840,3956.13,365,-2.89471e-06,-4.08877e-05,0.000999199,-0.00214123,5.39,480.0,10.8387,195.0,480.0,2020-01-13 00:00:00,N +SMA America: SB50-1SP-US-40 {208V},208,27.0084,5000,5177.49,365,-3.63814e-06,-3.17522e-05,0.0030215,0.00025222,5.06,480.0,14.1849,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB50-1SP-US-40 {240V},240,32.2376,5000,5155.06,365,-3.27495e-06,-3.63102e-05,0.0017554,0.000115302,5.21,480.0,14.1235,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB50-1SP-US-41 {208V},208,26.7937,5000,5177.76,365,-3.64759e-06,-3.00019e-05,0.00283192,0.000132853,5.06,480.0,14.1857,220.0,480.0,2020-01-21 00:00:00,N +SMA America: SB50-1SP-US-41 {240V},240,31.9472,5000,5155.54,365,-3.27291e-06,-3.61511e-05,0.00179128,0.000192021,5.21,480.0,14.1248,220.0,480.0,2020-01-21 00:00:00,N +SMA America: SB50-1TP-US-40 {208V},208,27.0084,5000,5177.49,365,-3.63814e-06,-3.17522e-05,0.0030215,0.00025222,5.06,480.0,14.1849,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB50-1TP-US-40 {240V},240,32.2376,5000,5155.06,365,-3.27495e-06,-3.63102e-05,0.0017554,0.000115302,5.21,480.0,14.1235,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB50-1TP-US-41 {208V},208,26.7937,5000,5177.76,365,-3.64759e-06,-3.00019e-05,0.00283192,0.000132853,5.06,480.0,14.1857,220.0,480.0,2020-01-13 00:00:00,N +SMA America: SB50-1TP-US-41 {240V},240,31.9472,5000,5155.54,365,-3.27291e-06,-3.61511e-05,0.00179128,0.000192021,5.21,480.0,14.1248,220.0,480.0,2020-01-13 00:00:00,N +SMA America: SB60-1SP-US-40 {208V},208,26.7537,5490,5685.57,365,-3.08771e-06,-3.23165e-05,0.00261547,-0.000394862,5.06,480.0,15.5769,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB60-1SP-US-40 {240V},240,27.3432,6000,6201.79,365,-2.9603e-06,-3.66087e-05,0.00198366,0.000224561,5.21,480.0,16.9912,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB60-1SP-US-41 {208V},208,26.5182,5418,5612.17,365,-3.23092e-06,-3.18852e-05,0.00244913,-0.000540389,5.06,480.0,15.3758,220.0,480.0,2020-01-21 00:00:00,N +SMA America: SB60-1SP-US-41 {240V},240,26.6615,6000,6200.73,365,-2.86378e-06,-3.57936e-05,0.00200707,0.000276479,5.21,480.0,16.9883,220.0,480.0,2020-01-21 00:00:00,N +SMA America: SB60-1TP-US-40 {208V},208,26.7537,5490,5685.57,365,-3.08771e-06,-3.23165e-05,0.00261547,-0.000394862,5.06,480.0,15.5769,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB60-1TP-US-40 {240V},240,27.3432,6000,6201.79,365,-2.9603e-06,-3.66087e-05,0.00198366,0.000224561,5.21,480.0,16.9912,220.0,480.0,2019-02-15 00:00:00,N +SMA America: SB60-1TP-US-41 {208V},208,26.5182,5418,5612.17,365,-3.23092e-06,-3.18852e-05,0.00244913,-0.000540389,5.06,480.0,15.3758,220.0,480.0,2020-01-13 00:00:00,N +SMA America: SB60-1TP-US-41 {240V},240,26.6615,6000,6200.73,365,-2.86378e-06,-3.57936e-05,0.00200707,0.000276479,5.21,480.0,16.9883,220.0,480.0,2020-01-13 00:00:00,N +SMA America: SB70-1SP-US-40 {208V},208,20.768,6920,7205.99,365,-2.70645e-06,-2.96344e-05,0.00108581,-0.002042,5.37,480.0,19.7424,245.0,480.0,2019-02-15 00:00:00,N +SMA America: SB70-1SP-US-40 {240V},240,27.8318,7000,7258.11,365,-2.92897e-06,-2.5645e-05,0.00215599,0.000238822,5.1,480.0,19.8852,245.0,480.0,2019-02-15 00:00:00,N +SMA America: SB70-1SP-US-41 {208V},208,20.768,6923,7209.17,365,-2.70645e-06,-2.96549e-05,0.0010858,-0.002042,5.37,480.0,19.7511,245.0,480.0,2020-01-21 00:00:00,N +SMA America: SB70-1SP-US-41 {240V},240,27.4872,7000,7259.79,365,-2.9657e-06,-2.57007e-05,0.00215599,0.000238822,5.1,480.0,19.8898,245.0,480.0,2020-01-21 00:00:00,N +SMA America: SB70-1TP-US-40 {208V},208,20.768,6920,7205.99,365,-2.70645e-06,-2.96344e-05,0.00108581,-0.002042,5.37,480.0,19.7424,245.0,480.0,2019-02-15 00:00:00,N +SMA America: SB70-1TP-US-40 {240V},240,27.8318,7000,7258.11,365,-2.92897e-06,-2.5645e-05,0.00215599,0.000238822,5.1,480.0,19.8852,245.0,480.0,2019-02-15 00:00:00,N +SMA America: SB70-1TP-US-41 {208V},208,20.768,6923,7209.17,365,-2.70645e-06,-2.96549e-05,0.0010858,-0.002042,5.37,480.0,19.7511,245.0,480.0,2020-01-13 00:00:00,N +SMA America: SB70-1TP-US-41 {240V},240,27.4872,7000,7259.79,365,-2.9657e-06,-2.57007e-05,0.00215599,0.000238822,5.1,480.0,19.8898,245.0,480.0,2020-01-13 00:00:00,N +SMA America: SB77-1SP-US-40 {208V},208,18.8062,6920,7205.71,365,-2.59581e-06,-2.8111e-05,0.00244462,-0.00167479,5.37,480.0,19.7417,270.0,480.0,2019-02-15 00:00:00,N +SMA America: SB77-1SP-US-40 {240V},240,22.8596,7680,7971.64,365,-2.65e-06,-3.34943e-05,0.000769102,-0.00209632,5.1,480.0,21.8401,270.0,480.0,2019-02-15 00:00:00,N +SMA America: SB77-1SP-US-41 {208V},208,18.8062,6923,7208.89,365,-2.59581e-06,-2.81289e-05,0.00244461,-0.00167479,5.37,480.0,19.7504,270.0,480.0,2020-01-21 00:00:00,N +SMA America: SB77-1SP-US-41 {240V},240,22.8549,7680,7971.68,365,-2.65055e-06,-3.35049e-05,0.000769092,-0.00209633,5.1,480.0,21.8402,270.0,480.0,2020-01-21 00:00:00,N +SMA America: SB77-1TP-US-40 {208V},208,18.8062,6920,7205.71,365,-2.59581e-06,-2.8111e-05,0.00244462,-0.00167479,5.37,480.0,19.7417,270.0,480.0,2019-02-15 00:00:00,N +SMA America: SB77-1TP-US-40 {240V},240,22.8596,7680,7971.64,365,-2.65e-06,-3.34943e-05,0.000769102,-0.00209632,5.1,480.0,21.8401,270.0,480.0,2019-02-15 00:00:00,N +SMA America: SB77-1TP-US-41 {208V},208,18.8062,6923,7208.89,365,-2.59581e-06,-2.81289e-05,0.00244461,-0.00167479,5.37,480.0,19.7504,270.0,480.0,2020-01-13 00:00:00,N +SMA America: SB77-1TP-US-41 {240V},240,22.8549,7680,7971.68,365,-2.65055e-06,-3.35049e-05,0.000769092,-0.00209633,5.1,480.0,21.8402,270.0,480.0,2020-01-13 00:00:00,N +SMA America: SBS38-US-10 {240V},240,27.4596,3800,3923.94,360,-3.89864e-06,-1.9701e-05,0.00276128,0.00159082,6.53,550.0,10.8998,220.0,550.0,2020-01-13 00:00:00,N +SMA America: SBS50-US-10 {240V},240,25.2786,5000,5175.16,360,-3.28256e-06,-1.34142e-05,0.002327,0.00177911,6.53,550.0,14.3755,220.0,550.0,2020-01-13 00:00:00,N +SMA America: SBS60-US-10 {240V},240,21.743,6000,6215.31,360,-2.44388e-06,-2.42642e-05,0.0021026,0.000188484,6.53,550.0,17.2647,220.0,550.0,2020-01-13 00:00:00,N +SMA America: SBSE115-US-50 {208V},208,32.6074,10053,10372.9,405,-1.67255e-06,-3.48914e-05,0.000216015,-0.000888205,11.04,480.0,25.6121,200.0,480.0,NaN,Y +SMA America: SBSE115-US-50 {240V},240,30.4514,11483,11807.3,405,-1.22724e-06,-4.10083e-05,-0.00114009,-0.00225109,10.97,480.0,29.1538,200.0,480.0,NaN,Y +SMA America: SBSE38-US-50 {208V},208,30.8474,3332.02,3426.32,377,-8.36763e-06,-8.99166e-05,0.00152218,0.00115097,11.27,480.0,9.08838,91.0,480.0,NaN,Y +SMA America: SBSE38-US-50 {240V},240,29.7909,3869.94,3974.21,377,-4.2104e-06,-9.6563e-05,0.00156071,-0.00143969,11.22,480.0,10.5417,91.0,480.0,NaN,Y +SMA America: SBSE48-US-50 {208V},208,25.477,4165.99,4283.89,383,-4.44884e-06,-7.74682e-05,0.000528225,-0.00152041,11.27,480.0,11.1851,112.0,480.0,NaN,Y +SMA America: SBSE48-US-50 {240V},240,28.537,4822.89,4951.86,383,-3.09134e-06,-7.96109e-05,0.000983025,-0.00235104,11.22,480.0,12.9291,112.0,480.0,NaN,Y +SMA America: SBSE58-US-50 {208V},208,26.1675,4999.91,5142.83,389,-3.98859e-06,-6.34e-05,0.000320294,-0.001093,11.27,480.0,13.2207,136.0,480.0,NaN,Y +SMA America: SBSE58-US-50 {240V},240,25.582,5775.89,5929.49,389,-2.58927e-06,-6.697e-05,0.00108813,-0.00228946,11.22,480.0,15.2429,136.0,480.0,NaN,Y +SMA America: SBSE77-US-50 {208V},208,22.9017,6644.49,6844.11,400,-2.74739e-06,-5.22653e-05,-0.0009457,-0.00176337,11.27,480.0,17.1103,180.0,480.0,NaN,Y +SMA America: SBSE77-US-50 {240V},240,28.0347,7621.98,7841.79,400,-2.28768e-06,-5.06162e-05,0.000770932,-0.00126226,11.22,480.0,19.6045,180.0,480.0,NaN,Y +SMA America: SBSE96-US-50 {208V},208,29.7704,8338,8593.84,395,-1.761e-06,-4.25232e-05,0.000128998,-0.00139826,11.09,480.0,21.7566,168.0,480.0,NaN,Y +SMA America: SBSE96-US-50 {240V},240,31.456,9569,9832.45,395,-1.48766e-06,-4.77493e-05,0.000343137,-0.00186408,11.02,480.0,24.8923,168.0,480.0,NaN,Y +SMA America: SC 2500-EV-US {550V},550,8719.63,2353870,2.43339e+06,994,-1.04493e-08,7.85782e-06,0.000748558,-8.89658e-05,370.0,1425.0,2448.08,850.0,1425.0,2019-02-15 00:00:00,N +SMA America: SC 2660 UP-US 600V 2566A {600V},600,7986.58,2616157,2.71046e+06,970,-1.04197e-08,8.1623e-06,0.00103697,0.000205491,252.66,1200.0,2794.29,880.0,1200.0,NaN,Y +SMA America: SC 2750-EV-US {600V},600,11562.1,2600000,2.677e+06,957,-8.01208e-09,9.54173e-06,0.000910946,0.000213546,379.32,1200.0,2797.28,875.0,1200.0,2019-02-15 00:00:00,N +SMA America: SC 2800 UP-US 630V 2566A {630V},630,8439.13,2747472,2.84422e+06,1000,-9.84489e-09,8.13766e-06,0.000964304,0.000184015,247.1,1200.0,2844.22,921.0,1200.0,NaN,Y +SMA America: SC 2930 UP-US 660V 2566A {660V},660,8495.44,2841880,2.93961e+06,1030,-9.23536e-09,8.30907e-06,0.00101006,0.000230729,247.96,1200.0,2853.99,962.0,1200.0,NaN,Y +SMA America: SC 3060 UP-US 690V 2566A {690V},690,8826.9,2951143,3.0506e+06,1062,-8.75676e-09,8.99447e-06,0.00102501,0.000287266,255.77,1200.0,2872.5,1003.0,1200.0,NaN,Y +SMA America: SC 4000 UP-US 600V 3850A {600V},600,5617.77,3650134,3.72211e+06,970,-3.6849e-09,9.83713e-06,0.00225492,0.000857128,453.5,1200.0,3837.22,880.0,1200.0,NaN,Y +SMA America: SC 4200 UP-US 630V 3850A {630V},630,5895.68,3832828,3.9057e+06,1001,-3.28908e-09,8.94659e-06,0.0016127,0.000437708,451.8,1200.0,3901.8,921.0,1200.0,NaN,Y +SMA America: SC 4400 UP-US 660V 3850A {660V},660,6112.59,4017113,4.09035e+06,1032,-3.03546e-09,1.02934e-05,0.00170375,0.000800875,465.17,1200.0,3963.52,962.0,1200.0,NaN,Y +SMA America: SC 4600 UP-US 690V 3850A {690V},690,6433.98,4198235,4.27203e+06,1062,-2.84061e-09,1.09616e-05,0.00170778,0.00105648,471.07,1200.0,4022.63,1003.0,1200.0,NaN,Y +SMA America: SC-1850-US {385V},385,6101.72,1661000,1.71038e+06,665,-1.03226e-08,1.60558e-05,0.00216294,0.000455932,294.0,950.0,2572,570.0,950.0,2019-02-15 00:00:00,N +SMA America: SC-2200-US {385V},385,7223.31,2079000,2.1527e+06,665,-1.23191e-08,1.41834e-05,0.00145187,5.72707e-05,297.0,950.0,3237.15,570.0,950.0,2019-02-15 00:00:00,N +SMA America: SCS 2475-US {385V},385,7240.9,2.07889e+06,2.15264e+06,673,-1.2321e-08,1.44767e-05,0.00147915,5.84696e-05,297.0,950.0,3198.58,577.0,950.0,NaN,N +SMA America: SHP 125-US-20 {480V},480,135.941,125000,127378,830,-1.01828e-07,8.92279e-06,0.00237026,0.000131332,5.37,1200.0,153.468,705.0,1200.0,2020-02-03 00:00:00,N +SMA America: SHP 125-US-21 {480V},480,137.825,125000,127380,830,-1.02645e-07,8.86508e-06,0.00231566,0.000110427,2.42,1200.0,153.47,705.0,1200.0,NaN,N +SMA America: SHP 150-US-20 {600V},600,138.93,150000,152246,960,-6.43815e-08,8.36224e-06,0.00219329,0.00039548,6.63,1200.0,158.59,880.0,1200.0,2020-02-03 00:00:00,N +SMA America: SHP 150-US-21 {600V},600,138.93,150000,152246,960,-6.43815e-08,8.36224e-06,0.00219329,0.00039548,3.23,1200.0,158.59,880.0,1200.0,NaN,N +SMA America: SHP 165-US-21 {630V},630,169.734,165000,167400,994,-5.30857e-08,9.64117e-06,-0.000469682,0.000273283,4.16,1200.0,168.411,925.0,1200.0,NaN,N +SMA America: SHP 172-US-21 {660V},660,126.492,172000,174496,1089,-4.53857e-08,1.1415e-05,0.00141796,-0.000218599,4.24,1200.0,160.235,968.0,1200.0,NaN,N +SMA America: SHP FLEX-US-21 {208V},208,122.679,55076,57216,583,-4.00325e-07,5.64519e-06,0.00132766,0.000116709,2.87444,1195.0,98.1407,372.0,1195.0,2025-01-02 00:00:00,N +SMA America: SHP FLEX-US-21 {320V},320,146.019,84903.6,87060.4,680,-1.79824e-07,7.90987e-06,0.00144006,0.000145699,2.97525,1195.0,128.03,495.0,1195.0,NaN,N +SMA America: SHP FLEX-US-21 {380V},380,133.474,100842,103110,745,-1.35826e-07,7.44048e-06,0.00152537,0.000155843,3.07103,1195.0,138.403,582.0,1195.0,NaN,N +SMA America: SHP FLEX-US-21 {385V},385,133.474,100842,103110,745,-1.35826e-07,7.44048e-06,0.00152537,0.000155843,3.07,1195.0,138.403,582.0,1195.0,NaN,N +SMA America: SHP FLEX-US-21 {400V},400,163.709,105632,107872,800,-1.26233e-07,8.27063e-06,0.00158305,0.000244389,2.9,1200.0,134.84,590.0,1200.0,2025-01-02 00:00:00,N +SMA America: SHP FLEX-US-21 {420V},420,170.967,112714,114952,780,-1.09019e-07,8.18762e-06,0.00182279,0.000294642,3.17468,1195.0,147.375,630.0,1195.0,NaN,N +SMA America: SHP FLEX-US-21 {480V},480,135.941,125007,127386,830,-1.01828e-07,8.92275e-06,0.00237026,0.000131332,5.37,1200.0,153.477,705.0,1200.0,NaN,N +SMA America: SHP FLEX-US-21 {600V},600,138.93,150079,152327,960,-6.43815e-08,8.36335e-06,0.00219329,0.00039548,6.63,1200.0,158.674,880.0,1200.0,NaN,N +SMA America: SHP FLEX-US-21 {630V},630,169.734,165662,168078,994,-5.30857e-08,9.65396e-06,-0.000469682,0.000273283,4.16,1200.0,169.092,925.0,1200.0,NaN,N +SMA America: SHP FLEX-US-21 {660V},660,126.492,172810,175324,1089,-4.53857e-08,1.14026e-05,0.00141796,-0.000218599,4.24,1200.0,160.995,968.0,1200.0,NaN,N +SMA America: SI27-US208-20 {208V},208,141.402,27175.9,28565.2,775,-1.11572e-06,-3.01411e-05,-0.000391512,-0.000575831,17.602,980.0,36.8583,200.0,980.0,NaN,N +SMA America: SI60-US480-20 {480V},480,178.644,60414.4,61925,775,-2.67946e-07,-1.8288e-05,-0.000690358,-0.000926296,17.33,980.0,79.9032,415.0,980.0,NaN,N +SMA America: STP 13-US-50 {208V},208,38.7361,13000,13553.2,335,-1.51824e-06,1.75313e-05,0.00104394,-0.000199945,4.3,640.0,40.4572,230.0,640.0,NaN,N +SMA America: STP 20-US-50 {480V},480,75.5632,20000,20397,688,-2.89567e-07,-2.96292e-05,-0.00119914,-0.000510433,4.7,800.0,29.6468,350.0,800.0,2023-11-01 00:00:00,N +SMA America: STP 25-US-50 {480V},480,74.0371,25000,25475.6,708,-3.24977e-07,-2.48256e-05,-0.00100243,0.000671469,4.7,800.0,35.9825,430.0,800.0,2023-11-01 00:00:00,N +SMA America: STP 30-US-50 {480V},480,80.4006,30000,30598.2,714,-3.21981e-07,-2.37698e-05,-0.000505393,0.000451047,4.7,800.0,42.8546,515.0,800.0,2023-11-01 00:00:00,N +SMA America: STP 33-US-41 {480V},480,128.062,33300,34131,683,-3.31254e-07,-4.49997e-05,-0.000292618,-0.00235512,5.43,800.0,49.9722,330.0,800.0,2022-11-01 00:00:00,N +SMA America: STP 50-US-41 {480V},480,116.443,50000,51317.6,725,-2.65992e-07,-3.59463e-05,-0.00157906,-0.00182695,5.43,800.0,70.7829,500.0,800.0,2022-11-01 00:00:00,N +SMA America: STP 62-US-41 {480V},480,133.527,62500,64326.4,725,-2.8242e-07,-2.86446e-05,-0.00236445,-0.001396,5.43,800.0,88.726,500.0,800.0,2022-11-01 00:00:00,N +SMA America: STP12000TL-US-10 {480V},480,56.0753,12000,12273.9,675,-7.10206e-07,-3.52678e-05,-0.000324462,-0.00173807,1.79,800.0,18.1836,300.0,800.0,2019-02-15 00:00:00,N +SMA America: STP15000TL-US-10 {480V},480,52.4856,15000,15350.5,675,-5.87211e-07,-3.82472e-05,-0.000300578,-0.00170938,1.79,800.0,22.7414,300.0,800.0,2019-02-15 00:00:00,N +SMA America: STP20000TL-US-10 {480V},480,46.7203,20000,20475.1,695,-6.37674e-07,-3.26817e-05,-0.000483517,-0.000524834,1.79,800.0,29.4605,380.0,800.0,2019-02-15 00:00:00,N +SMA America: STP24000TL-US-10 {480V},480,46.6606,24000,24522.5,712,-4.29422e-07,-3.58689e-05,0.000150953,-0.000900321,1.79,800.0,34.4418,450.0,800.0,2019-02-15 00:00:00,N +SMA America: STP30000TL-US-10 {480V},480,63.0627,30000,30582.1,720,-3.55646e-07,-1.92894e-05,-0.000329177,-0.000275711,1.22,800.0,42.4752,500.0,800.0,2019-02-15 00:00:00,N +SMA America: STP50-US-40 {480V},480,124.31,50000,51128.1,725,-2.05005e-07,-2.28199e-05,-0.0037517,-0.00406976,5.1,800.0,70.5215,500.0,800.0,2019-02-15 00:00:00,N +SMA America: STPS27US-20 {208V},208,141.453,27000,28374,775,-1.11544e-06,-3.00093e-05,-0.000387521,-0.000572939,17.602,980.0,36.6116,200.0,980.0,NaN,N +SMA America: STPS60US-20 {480V},480,178.376,60000,61495,775,-2.68038e-07,-1.82933e-05,-0.000682918,-0.000929161,17.33,980.0,79.3484,415.0,980.0,NaN,N +SPITZER ENERGY COMPANY: SPZ 12KW-LV-A {208V},208,41.0561,7648,7919.97,360,-2.25575e-06,-1.9822e-05,-0.000763518,-0.000587419,15.0,480.0,21.9999,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 12KW-LV-A {240V},240,53.0573,7647,7921.64,360,-2.83516e-06,-1.80857e-05,-0.00030204,-8.8294e-05,15.0,480.0,22.0045,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 12KW-LV-B {208V},208,43.6503,8060,8356.75,360,-2.19669e-06,-1.82578e-05,-0.00067304,-0.00032298,17.78,480.0,23.2132,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 12KW-LV-B {240V},240,43.5443,8047,8334.67,360,-2.21153e-06,-1.82488e-05,-0.00066946,-0.000325811,15.0,480.0,23.1519,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 15KW-LV {208V},208,54.3475,10186,10560.2,360,-1.71758e-06,-1.83118e-05,-0.000733476,-0.000439537,16.94,480.0,29.3338,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 15KW-LV {240V},240,54.2141,10147,10509,360,-1.73767e-06,-1.81949e-05,-0.000673176,-0.000317833,18.0,480.0,29.1916,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 15KW-LV-B {208V},208,54.056,10186,10559.8,360,-1.70398e-06,-1.83483e-05,-0.000763056,-0.00046152,16.94,480.0,29.3328,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 15KW-LV-B {240V},240,54.222,10140,10501.5,360,-1.72665e-06,-1.82761e-05,-0.000567918,-0.00026723,16.67,480.0,29.1709,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 75KW-LV {208V},208,25.8481,5020,5195.39,360,-2.34121e-06,-3.28822e-05,-0.000773753,-0.00227295,15.0,480.0,14.4317,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 75KW-LV {240V},240,25.4303,5040,5196.39,360,-1.76159e-06,-4.08294e-05,-0.000662743,-0.00438374,15.0,480.0,14.4344,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 9KW-LV {208V},208,39.3472,6124,6337.1,360,-2.27837e-06,-2.94606e-05,-0.000829423,-0.000529414,19.2,480.0,17.6031,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ 9KW-LV {240V},240,39.6167,6149,6335.21,360,-1.56475e-06,-3.58904e-05,-0.000469452,-0.000730717,19.2,480.0,17.5978,200.0,480.0,2025-01-13 00:00:00,Y +SPITZER ENERGY COMPANY: SPZ-M1000-S {208V},208,1.41593,962,999.572,42,-4.41104e-06,-0.000473346,0.0267218,-0.267604,0.3,50.0,23.7993,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M1000-S {240V},240,3.4485,958,1003.39,42,-2.7991e-05,-0.000293633,-0.0379677,-0.0387857,0.5,50.0,23.8903,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M1000-W {208V},208,1.41593,962,999.572,42,-4.41104e-06,-0.000473346,0.0267218,-0.267604,0.3,50.0,23.7993,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M1000-W {240V},240,3.4485,958,1003.39,42,-2.7991e-05,-0.000293633,-0.0379677,-0.0387857,0.5,50.0,23.8903,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M800-S {208V},208,0.975306,721,751.212,42,-1.30219e-05,0.000274569,0.0986505,0.075813,0.3,50.0,17.886,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M800-S {240V},240,1.3483,723,753.434,42,-1.50312e-05,0.00017655,-0.00665003,0.00460258,0.4,50.0,17.9389,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M800-W {208V},208,0.975306,721,751.212,42,-1.30219e-05,0.000274569,0.0986505,0.075813,0.3,50.0,17.886,35.0,50.0,NaN,N +SPITZER ENERGY COMPANY: SPZ-M800-W {240V},240,1.3483,723,753.434,42,-1.50312e-05,0.00017655,-0.00665003,0.00460258,0.5,50.0,17.9389,35.0,50.0,NaN,N +SRNE Solar CoLtd: HEBP48100U240-Pro {208V},208,91.3786,10005.7,10495.3,362.5,-5.32327e-06,-1.82936e-05,-0.00122737,-0.00153201,72.5,450.0,28.9526,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP48100U240-Pro {240V},240,105.613,10008.2,10509.1,362.5,-6.00479e-06,-2.05952e-05,-0.000722063,-0.000538592,73.6,450.0,28.9906,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP48114U240-Pro {208V},208,84.6861,10009,10471,362.5,-4.55227e-06,1.14468e-05,-0.000769641,0.000407001,73.0,450.0,28.8855,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP48114U240-Pro {240V},240,89.4158,10008.2,10446.2,362.5,-3.72674e-06,2.75676e-05,0.00079092,0.00135647,73.7,450.0,28.8172,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP48120U240-Pro {208V},208,77.9024,10397.2,10898.3,362.5,-4.40278e-06,5.26225e-06,7.44128e-05,0.000241566,71.2,450.0,30.0642,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP48120U240-Pro {240V},240,77.179,11995.7,12573,362.5,-3.42965e-06,-5.05406e-06,-0.000326941,-0.000121808,74.3,450.0,34.6842,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP4880U240-Pro {208V},208,71.3351,8808.5,9201.41,362.5,-4.43298e-06,3.33376e-05,0.00176484,0.00198885,72.3,450.0,25.3832,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HEBP4880U240-Pro {240V},240,60.2878,8809.61,9184.83,362.5,-3.53958e-06,1.03314e-05,-0.00108244,-0.000785126,73.1,450.0,25.3375,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HESP48100U200-H {208V},208,91.3568,10006,10495.7,362.5,-5.32244e-06,-1.87948e-05,-0.00122615,-0.00154408,72.5,450.0,28.9537,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HESP48100U200-H {240V},240,105.684,10008,10509,362.5,-6.01106e-06,-2.10892e-05,-0.000730202,-0.000550931,73.6,450.0,28.9904,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HESP48120U200-H {208V},208,77.9108,10397,10898.1,362.5,-4.40128e-06,4.98274e-06,7.64747e-05,0.00023738,71.2,450.0,30.0636,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HESP48120U200-H {240V},240,77.1374,11996,12573.2,362.5,-3.42885e-06,-4.67868e-06,-0.000279953,-6.97201e-05,74.3,450.0,34.6847,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HESP4880U200-H {240V},240,60.2951,8810,9184.93,362.5,-3.53581e-06,1.03286e-05,-0.00110778,-0.000812087,73.1,450.0,25.3377,275.0,450.0,NaN,Y +SRNE Solar CoLtd: HESP4880U200-H {208V},208,71.3864,8809,9201.81,362.5,-4.43223e-06,3.36877e-05,0.00175878,0.00199342,72.3,450.0,25.3843,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-10K-UP {208V},208,91.3568,10006,10495.7,362.5,-5.32244e-06,-1.87948e-05,-0.00122615,-0.00154408,72.5,450.0,28.9537,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-10K-UP {240V},240,105.684,10008,10509,362.5,-6.01106e-06,-2.10892e-05,-0.000730202,-0.000550931,73.6,450.0,28.9904,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-10K-UPRO {208V},208,91.3786,10005.7,10495.3,362.5,-5.32327e-06,-1.82936e-05,-0.00122737,-0.00153201,72.5,450.0,28.9526,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-10K-UPRO {240V},240,105.613,10008.2,10509.1,362.5,-6.00479e-06,-2.05952e-05,-0.000722063,-0.000538592,73.6,450.0,28.9906,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-12K-UP {208V},208,77.9108,10397,10898.1,362.5,-4.40128e-06,4.98274e-06,7.64747e-05,0.00023738,71.2,450.0,30.0636,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-12K-UP {240V},240,77.1374,11996,12573.2,362.5,-3.42885e-06,-4.67868e-06,-0.000279953,-6.97201e-05,74.3,450.0,34.6847,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-12K-UPRO {208V},208,77.9024,10397.2,10898.3,362.5,-4.40278e-06,5.26225e-06,7.44128e-05,0.000241566,71.2,450.0,30.0642,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-12K-UPRO {240V},240,77.179,11995.7,12573,362.5,-3.42965e-06,-5.05406e-06,-0.000326941,-0.000121808,74.3,450.0,34.6842,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-8K-UP {208V},208,71.3864,8809,9201.81,362.5,-4.43223e-06,3.36877e-05,0.00175878,0.00199342,72.3,450.0,25.3843,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-8K-UP {240V},240,60.2951,8810,9184.93,362.5,-3.53581e-06,1.03286e-05,-0.00110778,-0.000812087,73.1,450.0,25.3377,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-8K-UPRO {208V},208,71.3352,8808.5,9201.41,362.5,-4.43298e-06,3.33376e-05,0.00176484,0.00198885,72.3,450.0,25.3832,275.0,450.0,NaN,Y +SRNE Solar CoLtd: SEI-8K-UPRO {240V},240,60.2878,8809.61,9184.83,362.5,-3.53958e-06,1.03314e-05,-0.00108244,-0.000785126,73.1,450.0,25.3375,275.0,450.0,NaN,Y +SYL (NINGBO) Battery Co Ltd: SP135UHL {480V},480,397.337,134536,138134,900,-6.62024e-08,2.54358e-05,0.00489917,0.00114227,23.99,1300.0,153.482,720.0,1300.0,NaN,N +SYL (NINGBO) Battery Co Ltd: SP1750UHL {690V},690,2162.54,1.75151e+06,1.77921e+06,1150,-6.08934e-09,-7.38171e-06,-0.00370983,-0.00370447,119.44,1500.0,1547.14,1000.0,1500.0,NaN,N +Savant Systems Inc: PS-INV-10KW-100A-XX {240V},240,4.7171,9922.66,10512.2,360,7.69273e-07,-4.64871e-05,-0.0267633,0.00781544,21.92,530.0,29.2005,250.0,530.0,2024-12-23 00:00:00,Y +Savant Systems Inc: PS-INV-10KW-60A-XX {240V},240,4.7171,9922.66,10512.2,360,7.69273e-07,-4.64871e-05,-0.0267633,0.00781544,21.92,530.0,29.2005,250.0,530.0,NaN,Y +Savant Systems Inc: PS-INV-125KW-100A-XX {240V},240,61.5907,12410.9,12923.3,360,5.57501e-07,2.07472e-06,-0.00105812,0.00375016,19.49,530.0,35.8982,250.0,530.0,2024-12-23 00:00:00,Y +Savant Systems Inc: PS-INV-125KW-60A-XX {240V},240,61.5907,12410.9,12923.3,360,5.57501e-07,2.07472e-06,-0.00105812,0.00375016,19.49,530.0,35.8982,250.0,530.0,2023-01-11 00:00:00,Y +Schneider Electric USA Inc: CS1666-1-NA {575V},575,5271.05,1666000,1.70794e+06,1024,-9.42576e-09,6.47028e-06,0.00114172,0.00033868,295.0,1200.0,1667.91,856.0,1200.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: CS1666-2-NA {575V},575,5271.05,1666000,1.70794e+06,1024,-9.42576e-09,6.47028e-06,0.00114172,0.00033868,295.0,1200.0,1667.91,856.0,1200.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: CS1666-3-NA {575V},575,5271.05,1666000,1.70794e+06,1024,-9.42576e-09,6.47028e-06,0.00114172,0.00033868,295.0,1200.0,1667.91,856.0,1200.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: CS1800-NA {575V},575,5365.05,1800000,1.84746e+06,1024,-9.43859e-09,4.12657e-06,0.000826549,-0.000175231,295.0,1200.0,1804.16,856.0,1200.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: CS2000-NA {575V},575,6211.48,2000000,2.05885e+06,1042,-9.77861e-09,4.62546e-06,0.000694606,1.26825e-05,295.0,1195.0,1975.86,865.0,1195.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: CS2200-NA {600V},600,4691.38,2200000,2.26373e+06,1054,-9.9023e-09,4.93187e-06,0.000944078,-3.4489e-05,295.0,1200.0,2147.75,905.0,1200.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: Conext CL125 {600V},600,97.8066,125000,127418,945,-8.60127e-08,1.83928e-05,0.00421173,0.00247417,5.59,1200.0,134.834,860.0,1200.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: EMGPCS0500ACCANS00 {400V},400,2699.4,502611,515924,750,-2.20931e-08,2.83158e-05,0.00187491,-0.000154787,335.38,900.0,687.899,600.0,900.0,NaN,N +Schneider Electric USA Inc: HY8K1NA1 {240V},240,41.7915,7626,7849.25,360,-1.55823e-06,-5.04431e-05,-0.00079197,-0.00317271,13.71,480.0,21.8035,200.0,480.0,2025-09-22 00:00:00,Y +Schneider Electric USA Inc: XW Pro 6848 NA {120V},120,36.6271,5747,6249.38,52,-9.39722e-06,0.000143685,0.00109049,-0.00300489,17.4,58.0,120.18,47.0,58.0,2024-04-02 00:00:00,N +Schneider Electric USA Inc: XW Pro 6848 NA {240V},240,48.4908,6019,6528.28,52,-1.05329e-05,0.000185682,0.00254593,0.00143491,0.37,58.0,125.544,47.0,58.0,2024-04-02 00:00:00,N +Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV10K-H1H02 {240V},240,40.5923,9956.3,10242.6,370,-8.49006e-07,-1.75184e-05,-0.00105652,0.000474221,2.5,440.0,27.6827,300.0,440.0,NaN,Y +Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV114K-H1H02 {240V},240,43.9192,11370.5,11712.2,370,-1.08732e-06,-1.40766e-05,-0.0011544,0.000505528,2.5,440.0,31.6545,300.0,440.0,NaN,Y +Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV12K-H1H02 {240V},240,46.7423,11968.2,12332.9,370,-1.11762e-06,-1.33789e-05,-0.00104383,0.000740904,2.5,440.0,33.3322,300.0,440.0,NaN,Y +Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV76K-H1H02 {240V},240,32.785,7581.02,7787.78,370,-5.09915e-07,-2.14715e-05,-0.0010367,-0.000972918,2.5,440.0,21.0481,300.0,440.0,NaN,Y +Shanghai Chelion RenewableTechnology Co Ltd: iHome-INV96K-H1H02 {240V},240,40.872,9573.26,9845.35,370,-8.35392e-07,-1.67424e-05,-0.000562285,0.00138071,2.5,440.0,26.609,300.0,440.0,NaN,Y +Shenzhen Cubenergy Co Ltd: CBAC-140-HA-M-US {480V},480,462.607,140000,144055,900,-8.68082e-08,1.20146e-05,0.000836664,-4.1219e-05,316.0,1000.0,160.061,800.0,1000.0,NaN,N +Shenzhen Cubenergy Co Ltd: EH-0200-HA-M-US {690V},690,829.369,220432,225999,1199,-5.769e-08,8.89874e-06,0.00111707,-0.000236099,316.0,1346.0,188.49,1056.0,1346.0,NaN,N +Shenzhen Eternalplanet Energy Pingshan Ltd: HNA7G {240V},240,72.4285,7580,8032.54,350,-3.88026e-06,-7.04104e-05,-0.00228962,-0.0018072,23.0,480.0,22.9501,240.0,480.0,NaN,Y +Shenzhen Eternalplanet Energy Pingshan Ltd: HNA7G_AT {240V},240,72.4285,7580,8032.54,350,-3.88026e-06,-7.04104e-05,-0.00228962,-0.0018072,23.0,480.0,22.9501,240.0,480.0,NaN,Y +Shenzhen Eternalplanet Energy Pingshan Ltd: HNA7G_TT {240V},240,72.4285,7580,8032.54,350,-3.88026e-06,-7.04104e-05,-0.00228962,-0.0018072,23.0,480.0,22.9501,240.0,480.0,NaN,Y +Shenzhen Eternalplanet Energy Pingshan Ltd: HNA7W {240V},240,72.4285,7580,8032.54,350,-3.88026e-06,-7.04104e-05,-0.00228962,-0.0018072,23.0,480.0,22.9501,240.0,480.0,NaN,Y +Shenzhen Eternalplanet Energy Pingshan Ltd: HNA7W_TT {240V},240,72.4285,7580,8032.54,350,-3.88026e-06,-7.04104e-05,-0.00228962,-0.0018072,23.0,480.0,22.9501,240.0,480.0,NaN,Y +Shenzhen GSL Energy Co Ltd: GSL-H-12KLV-US {208V},208,46.0029,10499,10928.9,360,-2.04177e-06,-4.97058e-05,-0.000136348,3.84323e-05,14.5,480.0,30.358,230.0,480.0,NaN,Y +Shenzhen GSL Energy Co Ltd: GSL-H-12KLV-US {240V},240,23.4978,11933,12343.3,360,-8.92501e-07,-4.80052e-05,-0.00121621,-0.0023988,14.29,480.0,34.287,230.0,480.0,NaN,Y +Shenzhen GSL Energy Co Ltd: HS-LV10KNA {208V},208,91.3786,10005.7,10495.3,362.5,-5.32327e-06,-1.82936e-05,-0.00122737,-0.00153201,72.5,450.0,28.9526,275.0,450.0,NaN,Y +Shenzhen GSL Energy Co Ltd: HS-LV10KNA {240V},240,105.613,10008.2,10509.1,362.5,-6.00479e-06,-2.05952e-05,-0.000722063,-0.000538592,73.6,450.0,28.9906,275.0,450.0,NaN,Y +Shenzhen GSL Energy Co Ltd: HS-LV12KNA {208V},208,77.9024,10397.2,10898.3,362.5,-4.40278e-06,5.26225e-06,7.44128e-05,0.000241566,71.2,450.0,30.0642,275.0,450.0,NaN,Y +Shenzhen GSL Energy Co Ltd: HS-LV12KNA {240V},240,77.179,11995.7,12573,362.5,-3.42965e-06,-5.05406e-06,-0.000326941,-0.000121808,74.3,450.0,34.6842,275.0,450.0,NaN,Y +Shenzhen GSL Energy Co Ltd: HS-LV8KNA{208V},208,71.3352,8808.5,9201.41,362.5,-4.43298e-06,3.33376e-05,0.00176484,0.00198885,72.3,450.0,25.3832,275.0,450.0,NaN,Y +Shenzhen GSL Energy Co Ltd: HS-LV8KNA{240V},240,60.2878,8810,9185.24,362.5,-3.53958e-06,1.03306e-05,-0.00108244,-0.000785126,73.1,450.0,25.3386,275.0,450.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: GROWATT 10000MTLP-US {208V},208,27.6571,8630,8915.3,480,-1.52377e-06,-2.30297e-05,0.000679878,-3.21525e-05,3.3,550.0,18.5735,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 10000MTLP-US {240V},240,29.932,10058,10351.4,480,-9.15419e-07,-3.10357e-05,0.00317078,0.00391899,3.5,550.0,21.5655,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 10000MTLP-US {277V},277,37.9216,10165,10413.3,480,-1.19275e-06,-3.48675e-05,-0.00057534,-0.000991829,3.7,550.0,21.6943,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 33000TL3-US {480V},480,66.0415,32270,32886.9,700,-3.59919e-07,-2.38032e-05,0.000191208,-0.00113231,2.092,800.0,46.9813,480.0,800.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 36000TL3-US {480V},480,53.3355,35710,36402,700,-2.43629e-07,-2.24805e-05,-0.00105307,-0.00404007,2.051,800.0,52.0028,520.0,800.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 40000TL3-US {480V},480,47.4752,39850,40614,700,-1.53643e-07,-2.51112e-05,-0.00430446,-0.00896305,2.051,800.0,58.02,570.0,800.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {208V},208,24.6006,3620,3750.28,482,-1.50522e-06,-3.43246e-05,-0.00125181,0.00028353,0.05,550.0,7.78067,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {240V},240,25.7468,4050,4178.42,482,-1.15718e-06,-3.4709e-05,-0.0011941,0.000787473,0.05,550.0,8.66891,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 4000MTLP-US {277V},277,18.3224,4060,4175.79,482,1.76076e-06,-4.52648e-05,-0.00324143,0.00175301,0.05,550.0,8.66346,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 5000MTLP-US {208V},208,28.4647,4590,4759.82,482,-2.03379e-06,-3.55863e-05,-0.00095714,0.0001096,0.05,550.0,9.87515,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 5000MTLP-US {240V},240,29.172,5070,5239.35,482,-1.89627e-06,-3.92472e-05,-0.00109298,-0.000588173,0.05,550.0,10.87,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 5000MTLP-US {277V},277,27.9135,5060,5210.98,482,-1.39935e-06,-4.21157e-05,-0.00188421,0.000194372,0.05,550.0,10.8112,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 6000MTLP-US {208V},208,28.0561,5340,5549.46,482,-2.45818e-06,-3.59151e-05,-0.000928241,-1.23952e-05,0.05,550.0,11.5134,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 6000MTLP-US {240V},240,28.2403,6080,6290.75,482,-1.67447e-06,-2.84254e-05,-0.000931135,0.00100669,0.05,550.0,13.0513,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 6000MTLP-US {277V},277,29.68,6080,6268.23,482,-1.57408e-06,-4.54994e-05,-0.00190411,-0.00107207,0.05,550.0,13.0046,100.0,550.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 7000MTLP-US {208V},208,17.5337,6093,6366.17,385,-2.58838e-06,-3.6248e-05,0.000448921,-0.000190521,0.05,485.0,16.5355,280.0,485.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 7000MTLP-US {277V},277,31.914,7016.07,7270.86,385,-1.9358e-06,-5.44128e-05,-0.00114771,0.00124921,0.051,480.0,18.8854,275.0,480.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 7600MTLP-US {208V},208,15.7049,6741.01,7055.15,380,-2.46574e-06,-4.15455e-05,0.00111127,0.000564215,0.05,480.0,18.5662,270.0,480.0,2019-01-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {208V},208,26.6311,7107,7321.85,480,-1.82335e-06,-2.14896e-05,0.00147487,-0.000802315,3.3,550.0,15.2539,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {240V},240,30.2967,8061,8271.97,480,-1.4444e-06,-2.64555e-05,0.000283949,-0.0021629,3.5,550.0,17.2333,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 8000MTLP-US {277V},277,27.8083,8137,8320.55,480,-9.51957e-07,-3.30883e-05,-0.000874826,-0.00409973,3.7,550.0,17.3345,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {208V},208,25.6244,7864,8120.27,480,-1.77325e-06,-1.95392e-05,0.00154677,-0.000473763,3.3,550.0,16.9172,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {240V},240,29.7684,9061,9316.63,480,-1.52972e-06,-2.83176e-05,0.000635727,-0.0017766,3.5,550.0,19.4096,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: GROWATT 9000MTLP-US {277V},277,30.3799,9169,9379.77,480,-1.00793e-06,-3.68995e-05,-0.000343464,-0.00343368,3.7,550.0,19.5412,330.0,550.0,2018-10-15 00:00:00,N +Shenzhen Growatt New Energy Co Ltd: MIN 10000TL-XH-US {208V},208,29.0146,8760,9007.98,380,-1.28698e-06,-4.15848e-05,0.000622295,5.72289e-05,10.0,480.0,23.7052,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 10000TL-XH-US {240V},240,39.5146,10082,10328.5,380,-1.31953e-06,-4.36227e-05,0.000405515,-0.000846426,10.0,480.0,27.1802,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 10000TL-XH2 US {208V},208,45.6903,8606,9007.49,345,-2.55431e-06,-4.74357e-05,-0.000209092,-0.00143099,12.12,500.0,26.1087,150.0,500.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: MIN 10000TL-XH2 US {240V},240,45.8848,10057,10467.8,345,-1.70239e-06,-5.69571e-05,-0.00029647,-0.00096882,12.53,500.0,30.3415,150.0,500.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: MIN 11400TL-XH-US {208V},208,31.1947,10040,10308,380,-9.16002e-07,-3.559e-05,0.000574569,-0.00113531,10.0,480.0,27.1264,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 11400TL-XH-US {240V},240,41.2688,11520,11783.5,380,-1.09624e-06,-1.63085e-05,0.00014452,-2.54053e-05,10.0,480.0,31.0093,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 11400TL-XH2 US {208V},208,44.743,9827,10304.6,345,-2.32906e-06,-4.59681e-05,-8.55838e-05,-0.000917563,12.12,500.0,29.8683,150.0,500.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: MIN 11400TL-XH2 US {240V},240,45.9416,11354,11834.9,345,-1.7989e-06,-5.30052e-05,-0.000273277,-0.00113523,12.53,500.0,34.3042,150.0,500.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {208V},208,17.196,2626,2713.68,380,-4.99411e-06,-4.14824e-05,-0.00096125,-0.00156266,1.576,480.0,7.14127,125.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 3000TL-XH-US {240V},240,16.9589,3095,3184.22,380,-3.75554e-06,-3.82152e-05,-0.000858481,-0.00160756,1.593,480.0,8.37954,125.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 3800TL-XH-US {208V},208,24.4723,3324,3418.64,380,-4.39358e-06,-4.32261e-05,-0.000212206,-0.00036273,1.576,480.0,8.99641,160.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 3800TL-XH-US {240V},240,19.9959,3888,3987.16,380,-2.96039e-06,-4.18045e-05,-0.000716973,-0.000643354,1.593,480.0,10.4925,160.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 5000TL-XH-US {208V},208,20.0951,4280,4401.03,380,-3.80382e-06,-3.8371e-05,-0.00161675,-0.00216058,1.576,480.0,11.5816,210.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 5000TL-XH-US {240V},240,21.1886,4943,5075.82,380,-3.22302e-06,-4.7108e-05,-0.000573923,-0.000712923,1.593,480.0,13.3574,210.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 6000TL-XH-US {208V},208,24.8637,5143,5303.07,380,-3.36204e-06,-3.41204e-05,-0.000145404,0.00104586,1.576,480.0,13.9554,170.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 6000TL-XH-US {240V},240,23.0661,5918,6084.58,380,-2.3168e-06,-4.22293e-05,-0.00156567,0.000104517,1.593,480.0,16.0121,170.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 7600TL-XH-US {208V},208,32.4639,6580,6776.33,380,-2.44481e-06,-3.25023e-05,-0.000582189,-0.000967108,1.576,480.0,17.8325,212.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 7600TL-XH-US {240V},240,35.2212,7524,7741.49,380,-2.91717e-06,-3.67176e-05,-0.000401827,-0.000518179,1.593,480.0,20.3723,212.0,480.0,2023-07-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 7600TL-XH2 US {208V},208,48.5515,6611,6899.09,345,-2.18909e-06,-5.26745e-05,-0.00135163,-0.00317064,12.12,500.0,19.9974,150.0,500.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: MIN 7600TL-XH2 US {240V},240,51.5179,7651,7946.82,345,-2.41852e-06,-4.27876e-05,2.89873e-05,-0.00129572,12.53,500.0,23.0343,150.0,500.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: MIN 8200TL-XH-US {208V},208,34.3674,7166,7356.19,380,-1.61392e-06,-3.93032e-05,0.00084191,0.000469394,10.0,480.0,19.3584,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 8200TL-XH-US {240V},240,42.4825,8251,8445.17,380,-1.52261e-06,-3.89029e-05,0.000360027,-0.000552598,10.0,480.0,22.2241,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 9000TL-XH-US {208V},208,33.0697,7874,8087.05,380,-1.47764e-06,-3.73932e-05,-0.000147108,-0.000661754,10.0,480.0,21.2817,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: MIN 9000TL-XH-US {240V},240,41.617,9063,9277.47,380,-1.37093e-06,-4.1912e-05,0.00028924,-0.000637612,10.0,480.0,24.4144,250.0,480.0,2023-03-13 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: SPH 10000TL-HU-US {208V},208,26.4924,9766.96,10145.9,370,-2.15664e-06,-2.52585e-05,-0.00445234,-0.00114693,71.72,450.0,27.4212,165.0,450.0,2025-08-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: SPH 10000TL-HU-US {240V},240,22.406,9925,10337.5,370,-1.94173e-06,-8.45941e-05,-0.00432694,-0.00194867,77.25,450.0,27.9392,165.0,450.0,2025-08-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: SPH 10000TL-HU-US(B) {208V},208,26.4924,9766.96,10145.9,370,-2.15664e-06,-2.52585e-05,-0.00445234,-0.00114693,71.72,450.0,27.4212,165.0,450.0,2025-08-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: SPH 10000TL-HU-US(B) {240V},240,22.406,9925,10337.5,370,-1.94173e-06,-8.45941e-05,-0.00432694,-0.00194867,77.25,450.0,27.9392,165.0,450.0,2025-08-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: SPH 3000TL BL-US {208V},208,56.2066,2999,3136.79,380,1.17462e-06,-3.75214e-05,0.00026466,0.00980191,15.128,480.0,8.25472,150.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 3000TL BL-US {240V},240,61.4787,2934,3070.31,380,-1.71724e-06,-3.73778e-05,0.000652501,-0.00370037,15.128,480.0,8.07976,150.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {208V},208,63.7418,3581,3742.59,380,-2.81796e-06,-4.80744e-05,0.000870523,-0.00140271,15.128,480.0,9.84892,150.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 3600TL BL-US {240V},240,60.0162,3608,3779.31,380,-1.91966e-06,-4.00032e-05,0.000533951,-0.00513651,15.128,480.0,9.94556,150.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {208V},208,60.8811,4004,4172.62,380,-3.60238e-06,-3.02215e-05,0.00101699,0.0027464,15.128,480.0,10.9806,150.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 4000TL BL-US {240V},240,63.8608,3988,4157.71,380,-4.28948e-06,-3.36393e-05,0.000950904,0.00175936,15.128,480.0,10.9414,180.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 4600TL BL-US {208V},208,63.072,4604,4792.55,380,-3.0623e-06,-4.00448e-05,0.000346245,2.44886e-05,15.128,480.0,12.612,180.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 4600TL BL-US {240V},240,70.661,4598,4791.05,380,-4.11906e-06,-3.64231e-05,0.000814132,0.000533685,15.128,480.0,12.608,180.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 5000TL BL-US {208V},208,66.964,4969,5175.95,380,-4.00549e-06,-2.89848e-05,0.000376355,6.14188e-05,15.128,480.0,13.6209,230.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 5000TL BL-US {240V},240,66.0803,4954,5164.13,380,-3.88002e-06,-2.76194e-05,0.000660656,0.000189833,15.128,480.0,13.5898,230.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {208V},208,26.0045,5232,5434.27,380,-2.62271e-06,-3.79762e-05,-0.0010087,0.00172896,15.128,480.0,14.3007,230.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 6000TL BL-US {240V},240,28.8271,5864,6091.43,380,-2.2282e-06,-3.75942e-05,-0.000966782,0.00197297,15.128,480.0,16.0301,230.0,480.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: SPH 8000TL-HU-US(B) {208V},208,32.9882,7907.51,8245.14,370,-3.70015e-06,-6.54588e-05,-0.0016896,7.66631e-07,54.38,450.0,22.2842,160.0,450.0,2025-08-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: SPH 8000TL-HU-US(B) {240V},240,24.8099,7925.1,8274.56,370,-2.45152e-06,-6.7498e-05,-0.00604736,-0.00494363,53.28,450.0,22.3637,160.0,450.0,2025-08-11 00:00:00,Y +Shenzhen Growatt New Energy Co Ltd: WIT 100K-A-US {480V},480,77.3521,99388.7,101648,819,-1.11421e-07,2.1153e-05,0.00167882,3.5344e-05,19.5,900.0,124.112,750.0,900.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 100K-AU-US {480V},480,77.3521,99388.7,101648,819,-1.11421e-07,2.1153e-05,0.00167882,3.5344e-05,19.5,900.0,124.112,750.0,900.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 100K-H-US {277V},277,484.988,99370.3,102913,660,-7.13045e-08,-2.92975e-05,-0.000409808,0.00186225,18.36,800.0,155.929,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 100K-H-US {480V},480,484.988,99370.3,102913,660,-7.13045e-08,-2.92975e-05,-0.000409808,0.00186225,18.36,800.0,155.929,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 100K-HU-US {277V},277,484.988,99370.3,102913,660,-7.13045e-08,-2.92975e-05,-0.000409808,0.00186225,18.36,800.0,155.929,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 100K-HU-US {480V},480,484.988,99370.3,102913,660,-7.13045e-08,-2.92975e-05,-0.000409808,0.00186225,18.36,800.0,155.929,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 28K-A-US L2 {208V},208,83.9326,27879.4,28775.3,512,-5.93713e-07,1.77797e-05,0.000473479,-0.00119716,19.84,650.0,56.2018,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 28K-AU-US L2 {208V},208,83.9326,27879.4,28775.3,512,-5.93713e-07,1.77797e-05,0.000473479,-0.00119716,19.84,650.0,56.2018,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 28K-H-US L2 {208V},208,234.659,27823.9,29366.8,445,-2.65526e-07,-1.35619e-05,0.000510001,0.00527978,16.6,550.0,65.9927,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 28K-HU-US L2 {208V},208,234.659,27823.9,29366.8,445,-2.65526e-07,-1.35619e-05,0.000510001,0.00527978,16.6,550.0,65.9927,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 35K-A-US L2 {208V},208,68.7685,34854.7,36077.8,512,-4.00489e-07,1.65316e-05,0.0033987,0.000405561,19.95,650.0,70.4644,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 35K-AU-US L2 {208V},208,68.7685,34854.7,36077.8,512,-4.00489e-07,1.65316e-05,0.0033987,0.000405561,19.95,650.0,70.4644,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 35K-H-US L2 {208V},208,264.926,34824.9,36870.1,445,-2.47891e-07,-1.0479e-05,-5.45384e-05,-0.00219084,16.8,550.0,82.8541,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 35K-HU-US L2 {208V},208,264.926,34824.9,36870.1,445,-2.47891e-07,-1.0479e-05,-5.45384e-05,-0.00219084,16.8,550.0,82.8541,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 40K-A-US L2 {208V},208,85.9337,39837.3,41361.4,512,-3.95013e-07,1.92354e-05,0.00377928,0.00082992,19.72,650.0,80.784,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 40K-AU-US L2 {208V},208,85.9337,39837.3,41361.4,512,-3.95013e-07,1.92354e-05,0.00377928,0.00082992,19.72,650.0,80.784,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 40K-H-US L2 {208V},208,341.228,39915.3,42384.3,445,-3.61663e-07,-5.14245e-06,0.000620818,0.000753618,16.86,550.0,95.2456,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 40K-HU-US L2 {208V},208,341.228,39915.3,42384.3,445,-3.61663e-07,-5.14245e-06,0.000620818,0.000753618,16.86,550.0,95.2456,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 50K-A-US {480V},480,132.275,49763.3,50559.7,819,-3.41223e-07,1.3187e-05,0.00131046,-0.000133558,19.65,900.0,61.7335,750.0,900.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 50K-AU-US {480V},480,132.275,49763.3,50559.7,819,-3.41223e-07,1.3187e-05,0.00131046,-0.000133558,19.65,900.0,61.7335,750.0,900.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 50K-H-US {277V},277,342.512,49218.3,50959.7,660,7.71221e-08,-3.91701e-05,0.000270146,-0.00693933,18.78,800.0,77.2117,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 50K-H-US {480V},480,342.512,49218.3,50959.7,660,7.71221e-08,-3.91701e-05,0.000270146,-0.00693933,18.78,800.0,77.2117,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {277V},277,342.512,49218.3,50959.7,660,7.71221e-08,-3.91701e-05,0.000270146,-0.00693933,18.78,800.0,77.2117,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 50K-HU-US {480V},480,342.512,49218.3,50959.7,660,7.71221e-08,-3.91701e-05,0.000270146,-0.00693933,18.78,800.0,77.2117,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 55K-A-US L2 {208V},208,93.0609,54797.8,57244.3,512,-3.87466e-07,1.95029e-05,0.000946848,0.000131264,19.72,650.0,111.805,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 55K-AU-US L2 {208V},208,93.0609,54797.8,57244.3,512,-3.87466e-07,1.95029e-05,0.000946848,0.000131264,19.72,650.0,111.805,380.0,650.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 55K-H-US L2 {208V},208,333.467,54972,58589.1,445,-3.51713e-07,-1.13231e-05,-5.04636e-05,-0.000604732,16.87,550.0,131.661,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 55K-HU-US L2 {208V},208,333.467,54972,58589.1,445,-3.51713e-07,-1.13231e-05,-5.04636e-05,-0.000604732,16.87,550.0,131.661,340.0,550.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 63K-A-US {480V},480,267.133,63428.1,64995.4,819,-2.23473e-07,2.1389e-05,0.000973662,0.000194823,18.95,900.0,79.3595,750.0,900.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 63K-AU-US {480V},480,267.133,63428.1,64995.4,819,-2.23473e-07,2.1389e-05,0.000973662,0.000194823,18.95,900.0,79.3595,750.0,900.0,NaN,N +Shenzhen Growatt New Energy Co Ltd: WIT 63K-H-US {277V},277,316.927,62569.8,64760.5,660,-2.19514e-08,-2.62952e-05,-0.00160268,0.0369075,18.66,800.0,98.122,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 63K-H-US {480V},480,316.927,62569.8,64760.5,660,-2.19514e-08,-2.62952e-05,-0.00160268,0.0369075,18.66,800.0,98.122,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 63K-HU-US {277V},277,316.927,62569.8,64760.5,660,-2.19514e-08,-2.62952e-05,-0.00160268,0.0369075,18.66,800.0,98.122,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 63K-HU-US {480V},480,316.927,62569.8,64760.5,660,-2.19514e-08,-2.62952e-05,-0.00160268,0.0369075,18.66,800.0,98.122,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 75K-H-US {277V},277,431.964,74588.7,77085.2,660,-2.50804e-08,-2.43981e-05,-4.82579e-05,0.0108095,18.39,800.0,116.796,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 75K-H-US {480V},480,431.964,74588.7,77085.2,660,-2.50804e-08,-2.43981e-05,-4.82579e-05,0.0108095,18.39,800.0,116.796,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 75K-HU-US {277V},277,431.964,74588.7,77085.2,660,-2.50804e-08,-2.43981e-05,-4.82579e-05,0.0108095,18.39,800.0,116.796,520.0,800.0,NaN,Y +Shenzhen Growatt New Energy Co Ltd: WIT 75K-HU-US {480V},480,431.964,74588.7,77085.2,660,-2.50804e-08,-2.43981e-05,-4.82579e-05,0.0108095,18.39,800.0,116.796,520.0,800.0,NaN,Y +Shenzhen Kstar New Energy Company Limited: E10KD {240V},240,18.7954,10036,10383.6,300,-1.8614e-06,-5.65726e-05,-0.00227003,-0.000995168,20.79,400.0,34.6119,240.0,400.0,NaN,Y +Shenzhen Kstar New Energy Company Limited: E12KD {240V},240,40.2152,12020,12483.8,300,-1.84786e-06,-6.0444e-05,-0.000542449,-0.00103564,20.79,400.0,41.6125,200.0,400.0,NaN,Y +Shenzhen Kstar New Energy Company Limited: E15KD {240V},240,35.6542,14993,15633,300,-2.02736e-06,-5.71733e-05,-0.00277353,-0.000954215,20.79,400.0,52.1101,240.0,400.0,NaN,Y +Shenzhen Kstar New Energy Company Limited: E8KD {240V},240,19.0782,8024,8277.73,300,-2.04228e-06,-6.18749e-05,-0.00105734,-0.000187263,20.79,400.0,27.5924,200.0,400.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: GEN-HB-US 25K {208V},208,23.9168,21663.2,22511,360,-3.04166e-07,-1.48962e-05,0.00168245,0.00226828,34.81,480.0,62.5307,190.0,480.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: GEN-HB-US 25K {240V},240,35.1685,25129.1,26085.9,360,-3.47867e-07,-5.71168e-06,0.000789562,0.00219744,28.42,480.0,72.4609,190.0,480.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: GEN-LB-US 13K {208V},208,27.0526,11325,11700.8,360,-1.2316e-06,-4.73891e-05,0.00623137,0.00668652,31.95,440.0,32.5022,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: GEN-LB-US 13K {240V},240,26.5914,12997,13495.5,360,-1.07915e-06,7.00777e-07,-0.00317168,0.000635055,29.57,440.0,37.4875,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: GEN-LB-US 16K {208V},208,39.4771,13899,14409.8,360,-1.08973e-06,-5.34221e-05,0.00257429,0.00116755,29.36,440.0,40.0273,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: GEN-LB-US 16K {240V},240,41.5179,16153,16720.1,360,-8.2465e-07,-4.92855e-05,-0.00445832,-0.00445344,29.36,440.0,46.4447,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 10K {208V},208,33.5377,9757.73,10152.7,360,-1.68485e-06,-4.23266e-05,-0.00245204,-0.000328366,14.8,480.0,28.202,210.0,480.0,2024-08-12 00:00:00,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 10K {240V},240,37.5127,9758.58,10151.7,360,-1.6392e-06,-4.82755e-05,-0.000632676,-0.00104769,14.3,480.0,28.1993,210.0,480.0,2024-08-12 00:00:00,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 12K {208V},208,46.0029,10499,10928.9,360,-2.04177e-06,-4.97058e-05,-0.000136348,3.84323e-05,14.5,480.0,30.358,230.0,480.0,2024-04-22 00:00:00,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 12K {240V},240,23.4978,11933,12343.3,360,-8.92501e-07,-4.80052e-05,-0.00121621,-0.0023988,14.29,480.0,34.287,230.0,480.0,2024-04-22 00:00:00,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 13K {208V},208,26.9513,11325,11700.6,360,-1.22507e-06,-4.79277e-05,0.00621459,0.00662452,31.95,440.0,32.5017,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 13K {240V},240,26.5992,12997.3,13496,360,-1.08e-06,5.20491e-07,-0.0032417,0.000575218,29.57,440.0,37.4888,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 16K {208V},208,39.5306,13898.7,14409.5,360,-1.09198e-06,-5.37289e-05,0.0025438,0.00111738,29.36,440.0,40.0263,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 16K {240V},240,41.6957,16153.2,16720.5,360,-8.27787e-07,-4.90724e-05,-0.00442787,-0.0043975,29.36,440.0,46.4457,250.0,440.0,NaN,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 8K {208V},208,31.3505,7859.95,8164.44,360,-2.04398e-06,-4.28777e-05,-0.00251919,-0.00202171,18.53,480.0,22.679,210.0,480.0,2024-08-12 00:00:00,Y +Shenzhen Lux Power Technology Co Ltd: LXP-LB-US 8K {240V},240,27.0274,7862.66,8149.67,360,-1.19698e-06,-3.71005e-05,-0.00274351,-0.0034595,18.84,480.0,22.638,210.0,480.0,2024-08-12 00:00:00,Y +Shenzhen Megarevo Technology Co Ltd: R10KH1NA {240V},240,67.4483,10154,10466.8,360,-2.51773e-06,-4.11592e-05,-0.00043456,-0.00147412,13.0848,430.0,29.0744,250.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R10KLNA {240V},240,51.9471,10177,10475.8,360,-1.26046e-06,-2.00269e-05,-4.72702e-05,-0.000721728,33.64,430.0,29.0994,280.0,430.0,2024-03-21 00:00:00,Y +Shenzhen Megarevo Technology Co Ltd: R11K4H1NA {240V},240,73.3237,11598,11945.6,360,-2.01783e-06,-2.82698e-05,2.96717e-05,-0.000449195,13.0512,430.0,33.1822,250.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R12KH1NA {240V},240,81.4708,12362,12734.9,360,-2.02248e-06,-2.99684e-05,-0.000534753,-0.00117493,13.0487,430.0,35.3747,250.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R12KLNA-P4 {240V},240,80.2486,12137.1,12565.3,360,-1.7921e-06,-2.14301e-05,-0.000196145,0.000239507,19.85,430.0,34.9035,200.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R12KLNA-P6 {240V},240,85.1404,12213.5,12659.9,360,-1.87273e-06,-2.31177e-05,-2.75529e-05,-0.000108519,13.202,430.0,35.1663,200.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R16KLNA-P6 {240V},240,114.437,16198.8,16793.4,360,-1.43046e-06,-1.80327e-05,0.000676517,0.00146957,20.465,430.0,46.6484,220.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R16LNA-P4 {240V},240,108.732,16130.9,16731.6,360,-1.47499e-06,-2.25214e-05,7.91041e-05,0.000394112,19.23,430.0,46.4767,220.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R5KH1NA {240V},240,30.5683,5081,5225.22,360,-4.50584e-06,-2.11051e-05,-0.000372496,-0.00022096,13.4332,430.0,14.5145,180.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R5KLNA {240V},240,29.3587,5089.7,5247.58,360,-3.6512e-06,-1.512e-05,0.000125821,0.000551915,22.6,430.0,14.5766,180.0,430.0,2024-03-21 00:00:00,Y +Shenzhen Megarevo Technology Co Ltd: R6KH1NA {240V},240,38.3949,6082,6266.21,360,-4.35291e-06,-3.03956e-05,-2.31602e-05,-0.000260684,13.02,430.0,17.4061,180.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R6KLNA {240V},240,33.6679,6117,6297.73,360,-2.58712e-06,-2.03092e-05,0.000191477,-0.0002564,22.99,430.0,17.4937,200.0,430.0,2024-03-21 00:00:00,Y +Shenzhen Megarevo Technology Co Ltd: R7K6H1NA {240V},240,51.7401,7765,8006.77,360,-3.55298e-06,-2.37795e-05,0.000166036,0.000123343,13.3655,430.0,22.241,180.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R7K6LNA {240V},240,37.4864,7765,7993.33,360,-1.60481e-06,-2.20802e-05,-0.000935129,-0.00139184,30.71,430.0,22.2037,220.0,430.0,2024-03-21 00:00:00,Y +Shenzhen Megarevo Technology Co Ltd: R8KH1NA {240V},240,55.4496,8116,8353.47,360,-3.2612e-06,-2.7195e-05,-0.000442799,-0.000484882,13.021,430.0,23.2041,200.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R8KLNA {240V},240,65.6455,8084,8326.69,360,-2.93482e-06,-6.00257e-06,-0.000923485,-0.00173197,17.4,430.0,23.1297,250.0,430.0,2024-03-21 00:00:00,Y +Shenzhen Megarevo Technology Co Ltd: R8KLNA-P4 {240V},240,52.3715,8110.97,8386.82,360,-2.26235e-06,-2.47114e-05,-0.000140609,-0.000138584,20.205,430.0,23.2967,150.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R8KLNA-P6 {240V},240,60.1542,8180.92,8470.93,360,-2.89652e-06,-1.67967e-05,0.000448604,0.00115722,19.254,430.0,23.5304,150.0,430.0,NaN,Y +Shenzhen Megarevo Technology Co Ltd: R9KH1NA {240V},240,58.1522,9103,9381.47,360,-2.81278e-06,-2.57972e-05,-0.000220074,-0.000205891,13.1397,430.0,26.0597,200.0,430.0,NaN,Y +Shenzhen Poweroak Newener Co Ltd: EP900 {240V},240,68.4122,9230,9797.45,100,-3.77799e-06,-0.000408964,0.00300555,-0.0155763,11.7,113.0,97.9745,86.0,113.0,2025-12-01 00:00:00,Y +Shenzhen Poweroak Newener Co Ltd: EnergyPro 13K {240V},240,51.9594,13196.1,13616,420,-1.37033e-06,4.0547e-05,0.00281602,0.000870572,16.4,500.0,32.4191,370.0,500.0,2025-10-13 00:00:00,Y +Shenzhen Poweroak Newener Co Ltd: EnergyPro 6K {240V},240,37.066,5777,6067.17,76,-2.88789e-06,-0.000545054,-0.019298,-0.0652192,10.68,87.0,79.8311,63.0,87.0,NaN,N +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US {240V},240,50.6752,10010.9,10362.7,380,-1.11564e-06,-6.61416e-05,-0.000452634,-0.00267001,10.12,480.0,27.2703,135.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL10K-P2US-S {240V},240,50.6752,10010.9,10362.7,380,-1.11564e-06,-6.61416e-05,-0.000452634,-0.00267001,10.12,480.0,27.2703,135.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL12K-P2US {240V},240,47.5069,12014.5,12447.4,380,-1.2097e-06,-6.21825e-05,-0.00131058,-0.0021937,10.39,480.0,32.7563,161.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL12K-P2US-S {240V},240,47.5069,12014.5,12447.4,380,-1.2097e-06,-6.21825e-05,-0.00131058,-0.0021937,10.39,480.0,32.7563,161.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US {240V},240,49.0214,15014.8,15596.5,380,-1.2472e-06,-5.40958e-05,-0.00144971,-0.00136986,10.08,480.0,41.0434,202.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL15K-P2US-S {240V},240,49.0214,15014.8,15596.5,380,-1.2472e-06,-5.40958e-05,-0.00144971,-0.00136986,10.08,480.0,41.0434,202.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL8K-P2US {240V},240,51.452,7981.39,8255.49,380,-1.52067e-06,-7.70681e-05,-0.000266767,-0.00307047,10.39,480.0,21.725,108.0,480.0,NaN,Y +Shenzhen SOSEN Innovation Technology CoLtd: SSE-HL8K-P2US-S {240V},240,51.452,7981.39,8255.49,380,-1.52067e-06,-7.70681e-05,-0.000266767,-0.00307047,10.39,480.0,21.725,108.0,480.0,NaN,Y +Shenzhen Senergy Technology Co Ltd: SE 10KHB-210-T2/UL {208V},208,54.2796,10185.8,10559.9,360,-1.71331e-06,-1.83926e-05,-0.000737478,-0.000447449,18.0,480.0,29.3331,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 10KHB-210-T2/UL {240V},240,54.1553,10147.2,10509.2,360,-1.73518e-06,-1.82368e-05,-0.000687057,-0.000339617,18.0,480.0,29.1921,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 11K4HB-210-T2/UL {208V},208,54.222,10186,10549.8,360,-1.72665e-06,-1.82893e-05,-0.000567918,-0.00026723,16.67,480.0,29.3051,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 11K4HB-210-T2/UL {240V},240,54.056,10140,10511.5,360,-1.70398e-06,-1.83234e-05,-0.000763056,-0.00046152,16.94,480.0,29.1986,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {208V},208,61.6672,11608.8,12035.1,360,-1.50179e-06,-1.82274e-05,-0.000758378,-0.000422684,19.0,480.0,33.4308,200.0,480.0,NaN,Y +Shenzhen Senergy Technology Co Ltd: SE 11K4HB-T2/LV-ULP {240V},240,61.3766,11566.9,11979.4,360,-1.50555e-06,-1.78931e-05,-0.000504513,-0.000114654,19.0,480.0,33.276,200.0,480.0,NaN,Y +Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {208V},208,25.8481,5020,5195.39,360,-2.34121e-06,-3.28822e-05,-0.000773753,-0.00227295,15.0,480.0,14.4317,200.0,480.0, ,Y +Shenzhen Senergy Technology Co Ltd: SE 5KHB-130-D2/UL {240V},240,25.4303,5040,5196.39,360,-1.76159e-06,-4.08294e-05,-0.000662743,-0.00438374,15.0,480.0,14.4344,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 6KHB-130-D2/UL {208V},208,39.3864,6124,6337.09,360,-2.2815e-06,-2.94362e-05,-0.000836324,-0.000530048,19.2,480.0,17.603,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 6KHB-130-D2/UL {240V},240,39.5467,6149,6335.07,360,-1.55044e-06,-3.56627e-05,-0.000470728,-0.000725429,19.2,480.0,17.5974,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 7K6HB-180-T2/UL {208V},208,40.9402,7648,7920.05,360,-2.24833e-06,-2.00774e-05,-0.000791749,-0.000648654,15.0,480.0,22.0002,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 7K6HB-180-T2/UL {240V},240,53.1546,7647.2,7921.81,360,-2.84372e-06,-1.81162e-05,-0.00030388,-9.33021e-05,15.0,480.0,22.005,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {208V},208,43.7091,8060,8356.56,360,-2.20044e-06,-1.83504e-05,-0.000671882,-0.000326709,17.78,480.0,23.2127,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Senergy Technology Co Ltd: SE 8KHB-180-T2/UL {240V},240,43.62,8047.2,8334.81,360,-2.2152e-06,-1.82502e-05,-0.0006663,-0.000325195,15.0,480.0,23.1522,200.0,480.0,2025-04-01 00:00:00,Y +Shenzhen Sinexcel Electric Co Ltd: PWS1-100K-NA {480V},480,1317.27,98013,103790,650,-2.74157e-07,2.26405e-05,0.000272335,-0.000205388,997.0,850.0,159.677,500.0,850.0,2018-10-15 00:00:00,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-150K-NA {480V},480,1737.62,147470,155829,650,-1.73804e-07,2.0327e-05,0.000400891,-9.36496e-05,1360.0,850.0,239.737,500.0,850.0,2018-10-15 00:00:00,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-1725KTL-H-NA-8M1 {690V},690,12029.7,1708180,1.82804e+06,1300,1.47352e-09,-3.07784e-06,0.00345468,-0.00122008,321.25,1450.0,1406.18,1080.0,1450.0,NaN,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-1725KTL-H-NA-8M8 {690V},690,17148.7,1710710,1.84347e+06,1300,-1.09543e-08,3.17539e-05,0.00322456,0.00502861,310.06,1450.0,1418.06,1080.0,1450.0,NaN,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-250K-NA {480V},480,2004.62,244026,256764,650,-1.05159e-07,2.34527e-05,0.00070814,5.66666e-05,1860.0,850.0,395.022,500.0,850.0,2018-10-15 00:00:00,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA {400V},400,2863.59,498340,518484,750,-3.95908e-08,1.90443e-05,0.00118675,0.000259979,289.9,900.0,691.312,640.0,900.0,2018-10-15 00:00:00,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA-8M1 {400V},400,3239.07,498340,517739,750,-3.54003e-08,1.9006e-05,0.00104036,0.00026278,289.9,900.0,690.319,640.0,900.0,NaN,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-500KTL-NA-8M8 {400V},400,3241.03,498754,518130,750,-3.51438e-08,1.79329e-05,0.000901446,2.96558e-05,289.8,900.0,690.84,640.0,900.0,NaN,N +Shenzhen Sinexcel Electric Co Ltd: PWS1-50K-NA {480V},480,659.117,48580,51511.3,650,-5.80343e-07,2.15375e-05,0.00038408,1.84094e-05,860.0,850.0,79.2481,500.0,850.0,2018-10-15 00:00:00,N +Shenzhen Sinexcel Electric Co Ltd: PWS2-30K-NA {480V},480,154.571,30020,31070.6,600,-4.64201e-07,-5.58656e-05,-0.00176721,-0.00210332,1.857,750.0,51.7844,350.0,750.0,2021-10-01 00:00:00,N +Shenzhen Sinexcel Electric Co Ltd: PWS2-30P-NA {480V},480,293.214,29907,31128.2,600,-4.61579e-07,-4.5745e-05,-0.00035557,-0.00233174,36.02,750.0,51.8803,355.0,750.0,NaN,N +Shenzhen Sinexcel Isuna Energy Technology Co Ltd: Isuna U10K-PH {240V},240,53.878,10074,10355.6,320,-4.52316e-07,-3.82652e-05,-0.00201234,8.00863e-05,21.406,500.0,32.3611,140.0,500.0,NaN,Y +Shenzhen Sinexcel Isuna Energy Technology Co Ltd: Isuna U15K-PH {240V},240,47.3822,15042,15515.4,320,-8.02496e-07,-4.27812e-05,-0.00179938,-0.000903743,21.42,500.0,48.4857,140.0,500.0,NaN,Y +Shenzhen Sinexcel Isuna Energy Technology Co Ltd: Isuna U20K-PH {240V},240,82.1895,20181,20952.5,320,-1.29154e-06,-3.35472e-05,-0.000876602,0.000499824,21.408,500.0,65.4766,140.0,500.0,NaN,Y +Sichuan Clou Energy Electric Co Ltd: NEPCS-1600 {630V},630,1225.51,1.61728e+06,1.64329e+06,1200,-2.63606e-09,1.08067e-05,0.000179024,0.000766049,581.0,1500.0,1369.41,915.0,1500.0,NaN,N +Sichuan Clou Energy Electric Co Ltd: NEPCS-2000 {690V},690,1370.12,2000400,2.03008e+06,1250,-1.78626e-09,1.23546e-05,2.15365e-05,0.000811525,685.0,1500.0,1624.06,1050.0,1500.0,NaN,N +Sichuan Clou Energy Electric Co Ltd: NEPCS-2300 {800V},800,1577.68,2299960,2.33505e+06,1350,-1.62944e-09,1.85621e-05,-0.00115708,-0.00036411,752.0,1500.0,1729.66,1200.0,1500.0,NaN,N +Sichuan Clou Energy Electric Co Ltd: NEPCS-2600 {900V},900,2281.86,2602350,2.64422e+06,1400,-2.44829e-09,2.39359e-05,0.0013059,0.00168755,879.0,1500.0,1888.73,1320.0,1500.0,NaN,N +Sichuan Clou Energy Electric Co Ltd: NEPCSH-3200 {630V},630,2214.21,3.20057e+06,3.25162e+06,1200,-1.20512e-09,1.04319e-05,-0.000306648,0.000327913,1379.0,1500.0,2709.68,915.0,1500.0,NaN,N +Siemens Industry Inc: blueplanet125 TL3 GEN2 M1 WM OD USP0 {600V},600,108.596,136470,138301,1000,-5.22214e-08,1.01051e-05,0.00255317,0.00054023,5.27,1300.0,138.301,875.0,1300.0,2025-10-01 00:00:00,N +Siemens Industry Inc: blueplanet125 TL3 GEN2 M1 WM OD USPX {600V},600,108.596,136470,138301,1000,-5.22214e-08,1.01051e-05,0.00255317,0.00054023,5.27,1300.0,138.301,875.0,1300.0,2025-10-01 00:00:00,N +Sigenergy Technology Co Ltd: SigenMicro 384 US {240V},240,7.39731,388.06,398.455,45,-0.000110501,0.000130442,-0.00802627,-0.00336874,0.04,55.0,8.85455,35.0,55.0,NaN,N +Sigenergy Technology Co Ltd: SigenMicro 480 US {240V},240,7.75082,484,497.464,45,-7.28432e-05,-0.000445026,-0.017807,-0.0438643,0.04,55.0,11.0548,35.0,55.0,NaN,N +Sigenergy Technology Co Ltd: SigenMicro 768 US {240V},240,14.512,776,808.324,45,-8.80721e-05,-0.00204911,-0.0129525,-0.0596331,0.04,55.0,17.9628,35.0,55.0,NaN,N +Sigenergy Technology Co Ltd: SigenMicro 960 US {240V},240,15.7589,969,1014.15,45,-7.38129e-05,-0.00248805,-0.0126507,-0.0684891,0.04,55.0,22.5367,35.0,55.0,NaN,N +Sigenergy Technology Co Ltd: SigenStor EC 48 SP US {240V},240,20.636,4808,4948.52,360,-1.86359e-06,-7.25265e-06,0.000427717,-0.000219266,3.3,480.0,13.7459,270.0,480.0,NaN,Y +Sigenergy Technology Co Ltd: SigenStor EC 57 SP US {240V},240,20.3544,5776,5950.03,360,-1.6812e-06,-6.23562e-06,0.000753848,0.00028414,3.3,480.0,16.5279,270.0,480.0,NaN,Y +Sigenergy Technology Co Ltd: SigenStor EC 76 SP US {240V},240,18.0516,7649,7893.29,360,-1.37034e-06,-6.66298e-06,0.000569796,3.35688e-05,3.3,480.0,21.9258,270.0,480.0,NaN,Y +Sigenergy Technology Co Ltd: SigenStor EC 96 SP US {240V},240,14.4735,9653.3,9976.98,360,-1.06616e-06,-1.2831e-05,-0.000168485,-0.00134474,3.3,480.0,27.7138,270.0,480.0,NaN,Y +Sigenergy Technology Co Ltd: SigenStor EC SP US {240V},240,19.1039,11503,11889,360,-1.07139e-06,-7.59959e-06,0.00051217,-0.000253083,9.6,480.0,33.025,270.0,480.0,2025-10-01 00:00:00,Y +SimpliPhi Power: SPHI-IN-6 {120V},120,109.649,6017.66,6364.83,370,-3.02436e-06,5.95114e-06,0.00115198,-0.000174402,43.0,500.0,17.2022,250.0,500.0,NaN,Y +Sol-Ark: 30K-3P-208V {120V},120,95.5145,30025,31420.4,385,-9.13777e-07,8.98357e-06,0.00018143,0.000242698,31.9,500.0,81.6114,270.0,500.0,2025-07-11 00:00:00,Y +Sol-Ark: 5K-120V/8K-230V-1P {120V},120,15.6506,4787.1,5008.18,312.5,-5.70296e-06,6.79119e-06,0.00105549,0.000766521,11.7,425.0,16.0262,200.0,425.0,2024-05-13 00:00:00,Y +Sol-Ark: 5K-120V/8K-230V-1P {240V},240,26.6709,7970.3,8338.57,312.5,-3.50061e-06,1.20283e-05,-0.000808146,-0.00025741,19.3,425.0,26.6834,200.0,425.0,2024-05-13 00:00:00,Y +Sol-Ark: 60K-3P-480V {277V},277,285.708,60050,61997.1,695,-5.47422e-07,3.60259e-06,-0.000145593,-0.000123233,5.29,850.0,89.2045,540.0,850.0,2025-07-11 00:00:00,Y +Sol-Ark: Limitless 10K-LV {208V},208,48.0555,8635,8965.2,370,-2.84566e-06,7.03624e-06,-0.000546991,-0.000215731,5.29,425.0,24.2303,250.0,425.0,NaN,Y +Sol-Ark: Limitless 10K-LV {240V},240,65.4795,9970,10362.7,370,-3.27348e-06,-3.46291e-06,0.00158833,0.00159592,5.29,425.0,28.0073,250.0,425.0,NaN,Y +Sol-Ark: Limitless 15K-LV {208V},208,70.9245,13010,13511.4,320,-1.95422e-06,-2.30341e-07,-5.48824e-05,9.23257e-05,21.2,425.0,42.223,200.0,425.0,2023-02-13 00:00:00,Y +Sol-Ark: Limitless 15K-LV {240V},240,83.1383,15040,15606.1,320,-1.70708e-06,2.22463e-07,8.14388e-05,0.000201633,21.2,425.0,48.769,200.0,425.0,2023-02-13 00:00:00,Y +Sol-Ark: Limitless 18K-2P-LV {208V},208,87.2376,15550.2,15999.8,337.5,-5.19232e-07,-9.8876e-06,0.000664167,0.00270379,1.37,425.0,47.4067,250.0,425.0,2025-11-03 00:00:00,Y +Sol-Ark: Limitless 18K-2P-LV {240V},240,95.2313,17944.2,18463.2,337.5,-4.77499e-07,-5.80644e-06,0.000536975,0.00145514,1.37,425.0,54.7059,250.0,425.0,2025-11-03 00:00:00,Y +Sol-Ark: SA-MP-1000-208/240V {208V},208,12.0439,1001,1045.92,47.5,-2.54492e-05,0.000321277,0.000523419,0.014271,2.47,55.0,22.0193,40.0,55.0,NaN,N +Sol-Ark: SA-MP-1000-208/240V {240V},240,12.1306,1009,1052,47.5,-2.54403e-05,0.000319967,0.0003036,0.0153268,2.31,55.0,22.1474,40.0,55.0,NaN,N +Sol-Ark: Sol-Ark-12K-P {208V},208,82.0061,8818,9095.79,370,-1.96722e-06,-6.68524e-06,-0.00107261,-0.00276525,13.4,425.0,24.5832,240.0,425.0,2023-04-11 00:00:00,Y +Sol-Ark: Sol-Ark-12K-P {240V},240,87.4837,8982,9252.76,370,-2.22775e-06,2.8866e-06,0.00124658,0.00386378,13.4,425.0,25.0075,240.0,425.0,2023-04-11 00:00:00,Y +Sol-Ark: Sol-Ark-8k-48-ST {208V},208,87.4837,8982.17,9252.93,370,-2.22775e-06,2.88792e-06,0.00124658,0.00386378,13.4,425.0,25.0079,240.0,425.0,2023-04-11 00:00:00,Y +Sol-Ark: Sol-Ark-8k-48-ST {240V},240,82.0061,8818.09,9095.88,370,-1.96722e-06,-6.68566e-06,-0.00107261,-0.00276525,13.4,425.0,24.5835,240.0,425.0,2023-04-11 00:00:00,Y +Sol-Ark: Sol-Ark-9k-48-ST {208V},208,82.0061,8818,9095.79,370,-1.96722e-06,-6.68524e-06,-0.00107261,-0.00276525,13.4,425.0,24.5832,240.0,425.0,2023-04-11 00:00:00,Y +Sol-Ark: Sol-Ark-9k-48-ST {240V},240,87.4837,8982,9252.76,370,-2.22775e-06,2.8866e-06,0.00124658,0.00386378,13.4,425.0,25.0075,240.0,425.0,2023-04-11 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-38K-G2 {240V},240,40.8341,3810,3980.85,262.8,-4.72445e-06,-0.000100415,0.00125403,-0.00149334,1.2,450.0,15.1478,75.6,450.0,2026-01-12 00:00:00,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-50K-G2 {240V},240,38.6311,5030,5231.34,275.5,-2.90079e-06,-7.56354e-05,0.00116534,-0.00160809,1.2,449.9,18.9885,100.4,449.9,2026-01-12 00:00:00,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-60K-G2 {240V},240,37.0267,6035,6267.02,285.1,-2.2864e-06,-6.63378e-05,0.000968099,-0.00215828,1.2,449.9,21.9818,121.1,449.9,2026-01-12 00:00:00,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-AC-76K-G2 {240V},240,34.2555,7601,7887.41,300.1,-1.82032e-06,-5.83933e-05,0.000378563,-0.00227531,1.2,449.8,26.2826,149.7,449.8,2026-01-12 00:00:00,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-60-US {240V},240,77.7696,5732,6025.25,430,-2.60948e-06,-1.16235e-05,-0.000183991,-0.00125975,25.0,500.0,14.0122,360.0,500.0,NaN,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-70-US {240V},240,86.2952,6680,7047.85,390,-5.25849e-06,-1.08839e-05,0.000700888,-0.00052983,25.0,500.0,18.0714,280.0,500.0,NaN,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-76-US {240V},240,48.8966,7832,8223.37,375,-2.98068e-06,-4.56175e-05,-0.00242048,-0.00359598,49.5,430.0,21.929,320.0,430.0,2021-01-21 00:00:00,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Fit-86-US {240V},240,47.4759,8613,9035.99,396.5,-2.61282e-06,-4.21776e-05,0.00177193,-0.00158556,42.0,430.0,22.7894,363.0,430.0,2021-01-21 00:00:00,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-38K-G2 {240V},240,23.0534,3805,3915.44,337.9,-2.81602e-06,-3.68728e-05,0.00102784,0.00044996,1.2,499.5,11.5876,175.4,499.5,2026-01-12 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-50K-G2 {240V},240,17.7094,5003,5138.33,363.7,-1.73316e-06,-2.94407e-05,2.0865e-05,-0.000721874,1.2,499.9,14.1279,229.9,499.9,2026-01-12 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-60K-G2 {240V},240,20.099,6017,6177.57,388.3,-1.77531e-06,-2.62162e-05,0.00103226,-0.000265801,1.2,498.7,15.9093,277.0,498.7,2026-01-12 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-76K-G2 {208V},208,17.1216,6636.37,6814.19,360,-1.86153e-06,-5.17448e-05,-0.00145799,-0.00368684,5.44,440.0,18.9283,235.0,440.0,2026-01-12 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-HYB-76K-G2 {240V},240,20.2157,7593,7806,365.5,-1.71961e-06,-3.5814e-05,-0.000137721,-0.00170275,1.2,498.4,21.357,234.1,498.4,2026-01-12 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-60-US {240V},240,76.4939,5570,5867.43,335,-2.70981e-06,-4.25927e-05,0.000676665,-0.0022977,25.0,425.0,17.5147,240.0,425.0,NaN,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-70-US {240V},240,76.9232,6666,7018.43,360,-2.61451e-06,-4.12138e-05,0.00105761,-0.00230985,25.0,425.0,19.4956,290.0,425.0,NaN,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-76-US {240V},240,49.2438,7642,7986.08,402,-2.27199e-06,-4.04422e-05,-0.00127208,-0.000949817,44.0,500.0,19.8659,304.0,500.0,2021-01-21 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Hybrid-86-US {240V},240,47.3466,8604,9013.82,379,-2.55859e-06,-4.0658e-05,-0.000601146,-0.000323469,40.0,500.0,23.7832,258.0,500.0,2021-01-21 00:00:00,Y +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Micro 300P {240V},240,8.57749,320,335.004,38,-4.19283e-05,-0.000313872,-0.0280564,-0.174927,0.06,45.0,8.81589,27.5,45.0,NaN,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Micro 400P {240V},240,10.2412,410,430.153,38,-7.44571e-05,-0.000565324,-0.0191166,-0.0545903,0.06,45.0,11.3198,29.0,45.0,NaN,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Micro 450P {240V},240,11.0722,458,481.462,38,-6.21197e-05,-0.000638723,-0.0271171,-0.0752994,0.06,45.0,12.67,30.0,45.0,NaN,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Micro 500P {240V},240,10.5968,506,532.074,38,-5.497e-05,-0.000750984,-0.0258496,-0.0696392,0.061,45.0,14.002,30.0,45.0,NaN,N +SolaX Power Network Technology (Zhe jiang) Co Ltd: A1-Micro 600P {240V},240,13.6179,594,628.159,38,-6.84884e-05,-0.00102256,-0.0155596,-0.0629931,0.061,45.0,16.5305,32.5,45.0,NaN,N +SolarEdge Technologies Ltd: NX10000T-US {208V},208,23.9427,8600,8720.86,395,-1.34757e-06,1.46309e-05,0.00356171,0.000861214,5.64,450.0,22.0781,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX10000T-US {240V},240,15.8085,10000,10127.6,395,-7.92215e-07,8.42516e-06,0.00410355,3.58919e-05,5.9,450.0,25.6394,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX11500T-US {208V},208,23.2223,9980,10135.9,395,-1.33176e-06,9.76897e-06,0.00388357,0.00019453,5.64,450.0,25.6605,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX11500T-US {240V},240,21.5152,11520,11680.7,395,-9.51776e-07,7.16628e-06,-0.00129083,-0.00213477,5.9,450.0,29.5713,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX13000T-US {208V},208,24.5692,11200,11393,395,-1.40744e-06,9.29878e-06,0.00297028,-7.13632e-05,5.64,450.0,28.843,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX13000T-US {240V},240,23.9387,13000,13202.5,395,-1.06316e-06,4.8901e-06,0.00347211,-4.06901e-05,5.9,450.0,33.424,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX3800T-US {208V},208,25.3517,3330,3367.32,395,-2.29356e-06,2.33792e-05,0.00319611,0.000697407,5.64,450.0,8.52487,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX3800T-US {240V},240,14.508,3840,3880.2,395,-2.26355e-07,2.1243e-05,0.00378466,-0.000271936,5.9,450.0,9.8233,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX5000T-US {208V},208,27.8162,4300,4348.25,395,-1.84702e-06,2.0697e-05,0.00321793,0.000624753,5.64,450.0,11.0082,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX5000T-US {240V},240,14.594,4990,5043.78,395,-6.43132e-07,1.64286e-05,0.00403643,0.000656815,5.904,450.0,12.7691,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX5700T-US {208V},208,24.8298,4990,5045.88,395,-1.67747e-06,1.67593e-05,0.00331175,0.000749901,5.64,450.0,12.7744,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX5700T-US {240V},240,16.6741,5760,5820.32,395,-6.0913e-07,1.42014e-05,0.0040075,8.15416e-05,5.9,450.0,14.735,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX6000T-US {208V},208,25.8617,5020,5076.06,395,-1.67257e-06,1.71041e-05,0.00322518,0.000370925,5.2,450.0,12.8508,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX6000T-US {240V},208,16.5904,6000,6063.73,395,-5.98934e-07,1.51039e-05,0.00406372,0.000459932,5.904,450.0,15.3512,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX7600T-US {208V},208,24.6528,6650,6731.78,395,-1.47377e-06,1.3474e-05,0.00337301,0.000184259,5.64,450.0,17.0425,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX7600T-US {240V},240,16.0399,7680,7766.57,395,-6.91667e-07,1.05538e-05,0.00416157,-0.000222174,5.9,450.0,19.6622,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX9600T-US {208V},208,23.6278,8320,8434.64,395,-1.32198e-06,1.381e-05,0.00357354,0.000674301,5.64,450.0,21.3535,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: NX9600T-US {240V},240,15.912,9600,9720.04,395,-7.54796e-07,8.45049e-06,0.00364252,-7.89213e-05,5.9,450.0,24.6077,370.0,450.0,NaN,Y +SolarEdge Technologies Ltd: SE10000A-US {208V},208,16.1139,9930,10242.8,375,-1.2384e-06,2.65377e-05,0.000266706,-0.000756252,5.75,480.0,27.3142,325.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE10000A-US {240V},240,17.4931,9940,10204.9,400,-9.00567e-07,2.54122e-05,-0.000385545,-0.000926955,5.95,480.0,25.5123,360.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE10000H-US {208V},208,19.7509,8694.27,8849.79,395,-1.78747e-06,1.14597e-05,0.00237414,0.000905398,5.71,460.0,22.4045,360.0,460.0,NaN,Y +SolarEdge Technologies Ltd: SE10000H-US {240V},240,28.6642,9994,10144.7,395,-1.67044e-06,4.44566e-05,0.000494639,0.0014565,6.0,480.0,25.6828,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE100KUS {480V},480,91.9985,33300,33878.9,850,-3.01562e-07,1.75008e-05,0.00258759,0.000861338,5.05,950.0,39.8575,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE10KUS {208V},208,47.3075,10033.7,10341.9,460,-1.16269e-06,3.28815e-05,0.00314441,0.00165292,0.01,600.0,22.4825,400.0,600.0,NaN,N +SolarEdge Technologies Ltd: SE10KUS {480V},480,45.3022,9850,10061.3,882,-1.04775e-06,1.24873e-06,0.000251921,0.000140613,3.13,962.0,11.4074,100.0,962.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE110KUS {480V},480,300.458,109988,111889,850,-8.42229e-08,2.12272e-05,0.00406884,0.00442437,7.3,950.0,131.635,795.0,950.0,NaN,N +SolarEdge Technologies Ltd: SE11400A-US {240V},240,17.7754,11390,11706.6,400,-8.95337e-07,2.59139e-05,0.000889756,0.00044636,5.95,480.0,29.2664,360.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE11400H-US {208V},208,30.3477,10001,10190.2,395,-2.12788e-06,3.39737e-06,-0.000329311,-0.00130923,5.71,480.0,25.798,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE11400H-US {240V},240,32.0943,11393,11576.6,395,-1.613e-06,1.39653e-07,3.66801e-06,-0.00181235,6.0,480.0,29.3078,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE120KUS {480V},480,83.1716,40252,41001.3,850,-2.56628e-07,2.0623e-05,0.00336804,0.00233796,7.43,950.0,48.2369,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE144KUS {208V},208,48.2696,14510,15022.7,460,-1.34446e-06,2.62723e-05,0.000625902,-0.000851383,4.16,600.0,32.658,400.0,600.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE173KUS {208V},208,41.2948,16564,17165.4,460,-1.02493e-06,2.74878e-05,0.00385315,0.00129196,5.28,600.0,37.3162,400.0,600.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE20KUS {480V},480,46.0444,20050,20485.2,882,-3.20643e-07,1.07875e-05,0.00164318,-0.000236442,3.48,962.0,23.2259,842.0,962.0,2020-02-03 00:00:00,N +SolarEdge Technologies Ltd: SE250KUS {600V},600,639.268,249907,253198,1250,-3.59166e-08,3.62866e-06,0.00199869,0.000470843,21.61,1320.0,202.558,1090.0,1320.0,NaN,N +SolarEdge Technologies Ltd: SE285KUS {600V},600,645.7,284159,288163,1250,-3.63548e-08,2.43758e-06,0.00191372,0.000242669,21.6,1320.0,230.53,1090.0,1320.0,NaN,N +SolarEdge Technologies Ltd: SE3000H-US {240V},240,13.5015,2962,2986.83,395,-1.88271e-06,1.34232e-06,-0.00128768,-0.00353624,0.8886,480.0,7.5616,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE3000x {208V},208,9.79289,3020,3103.48,350,-3.86542e-06,1.79738e-05,0.00433055,0.000314927,3.71,480.0,8.8671,305.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE3000x {240V},240,14.2174,3010,3085.35,388,-3.14334e-06,5.18309e-06,0.000702697,-6.6326e-05,3.39,480.0,7.95193,100.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE30KUS {480V},480,56.4316,30159,30678.8,850,-2.1728e-07,1.21906e-05,0.00333474,0.00101919,7.06,950.0,36.0927,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE3300x {208V},208,10.9016,3288,3390.59,410,-2.81948e-06,3.21704e-05,0.00513054,0.00543269,5.55,500.0,8.26974,320.0,500.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE3300x {240V},240,13.323,3251,3340.04,435,-3.40269e-06,2.21243e-05,0.00297719,0.0018973,5.46,500.0,7.67825,370.0,500.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE330KUS {690V},690,735.577,329741,333628,1260,-2.84922e-08,3.94613e-06,0.00150014,-0.00041909,20.9,1400.0,264.784,1200.0,1400.0,NaN,N +SolarEdge Technologies Ltd: SE333KUS {480V},480,90.3895,33300,33865.5,850,-2.74928e-07,1.78607e-05,0.00273493,0.000939014,5.05,950.0,39.8417,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE3800A-US {208V},208,14.3963,3990,4121.27,410,-3.30451e-06,4.1227e-05,0.0039515,0.00413474,5.1,500.0,10.0519,320.0,500.0,2020-01-21 00:00:00,N +SolarEdge Technologies Ltd: SE3800A-US {240V},240,11.4887,3790,3863.83,400,-1.12449e-06,3.4594e-05,0.00760528,0.0181518,2.24,480.0,9.65958,360.0,480.0,NaN,Y +SolarEdge Technologies Ltd: SE3800H-US {208V},208,27.5109,3255,3298.76,395,-9.80145e-06,-1.95936e-06,-0.00599172,-0.00409497,4.12,480.0,8.3513,360.0,480.0,2025-08-01 00:00:00,Y +SolarEdge Technologies Ltd: SE3800H-US {240V},240,11.0144,3747,3779.2,395,-1.24139e-06,8.37674e-06,-0.000985094,0.00142458,1.1241,480.0,9.56759,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE40KUS {480V},480,83.1716,40252,41001.3,850,-2.56628e-07,2.0623e-05,0.00336804,0.00233796,7.43,950.0,48.2369,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE432KUS {208V},208,47.2971,14510,15020.2,460,-1.29295e-06,2.93236e-05,0.00082952,-0.000563898,4.16,600.0,32.6527,400.0,600.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE5000H-US {208V},208,12.5062,4979,5042.72,395,-1.09978e-06,2.38886e-05,0.0036578,0.00800927,4.51,480.0,12.7664,360.0,480.0,NaN,Y +SolarEdge Technologies Ltd: SE5000H-US {240V},240,12.7174,5052,5105.68,395,-8.14082e-07,2.11486e-05,0.00326182,0.00960945,4.52,480.0,12.9258,360.0,480.0,NaN,Y +SolarEdge Technologies Ltd: SE5000x {208V},208,8.30709,4980,5157.25,410,-2.51527e-06,1.02814e-05,-0.00435724,-0.00472301,5.46,500.0,12.5786,320.0,500.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE5000x {240V},240,11.9094,4990,5089.74,400,-1.23028e-06,2.19708e-05,-0.000117458,-0.00612996,2.24,480.0,12.7243,370.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE50KUS {208V},208,41.2948,16564,17165.4,460,-1.02493e-06,2.74878e-05,0.00385315,0.00129196,5.28,600.0,37.3162,400.0,600.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE5700H-US {208V},208,20.2214,4992.97,5059.79,395,-2.00708e-06,1.111e-05,0.00218248,0.00142374,5.71,460.0,12.8096,360.0,460.0,NaN,Y +SolarEdge Technologies Ltd: SE5700H-US {240V},240,13.0753,5700,5762.16,395,-8.26482e-07,2.3107e-05,0.00428684,0.0108574,4.51,480.0,14.5878,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE6000H-US {208V},208,15.9883,5054,5108.01,395,-1.18553e-06,2.06585e-05,0.00327453,0.00755942,4.52,480.0,12.9317,360.0,480.0,NaN,Y +SolarEdge Technologies Ltd: SE6000H-US {240V},240,12.1758,6046,6113.21,395,-6.891e-07,2.37011e-05,0.00406114,0.0109657,4.52,480.0,15.4765,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE6000x {208V},208,11.9749,5330,5530.11,410,-3.33321e-06,1.02371e-05,-0.00316284,-0.00331528,5.22,500.0,13.4881,320.0,500.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE6000x {240V},240,13.579,5990,6176.75,435,-2.22694e-06,5.42298e-06,0.0037044,-0.000186411,3.52,500.0,14.1994,370.0,500.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE666KUS {480V},480,91.9985,33300,33878.9,850,-3.01562e-07,1.75008e-05,0.00258759,0.000861338,5.05,950.0,39.8575,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE7600A-US {208V},208,19.0597,7560,7781,375,-1.52226e-06,3.37399e-05,0.00334072,0.00252878,5.75,480.0,20.7493,325.0,480.0,2018-10-15 00:00:00,N +SolarEdge Technologies Ltd: SE7600A-US {240V},240,18.5625,7625,7839.78,400,-2.14192e-06,1.79217e-05,0.00455904,0.000646974,2.16,480.0,19.5995,360.0,480.0,NaN,Y +SolarEdge Technologies Ltd: SE7600H-US {208V},208,19.8863,6591.78,6694.74,395,-1.86484e-06,7.92897e-06,0.00175502,0.000319004,5.71,460.0,16.9487,360.0,460.0,NaN,Y +SolarEdge Technologies Ltd: SE7600H-US {240V},240,17.4935,7616,7716.67,395,-1.40549e-06,3.65021e-06,-0.00120299,-0.00321721,4.52,480.0,19.5359,360.0,480.0,2025-07-01 00:00:00,Y +SolarEdge Technologies Ltd: SE80KUS {480V},480,83.1716,40252,41001.3,850,-2.56628e-07,2.0623e-05,0.00336804,0.00233796,7.43,950.0,48.2369,790.0,950.0,2023-02-01 00:00:00,N +SolarEdge Technologies Ltd: SE9600H-US {208V},208,18.2645,9578.35,9756.69,395,-1.76613e-06,4.06734e-06,0.00271693,0.000926693,5.71,460.0,24.7005,360.0,460.0,NaN,Y +SolarEdge Technologies Ltd: SE9600H-US {240V},240,18.6685,9568.49,9713.2,395,-1.38081e-06,3.63584e-06,0.00281662,0.00102157,6.0,460.0,24.5904,360.0,460.0,NaN,Y +SolarEdge Technologies Ltd: SE9KUS {208V},208,23.8657,8963,9338.22,424,-1.72245e-06,2.5445e-05,0.00434188,0.00212201,3.08,504.0,22.0241,384.0,504.0,2020-02-03 00:00:00,N +SolarJuice American Inc: S4A-A60 {240V},240,77.7696,5732,6025.25,430,-2.60948e-06,-1.16235e-05,-0.000183991,-0.00125975,25.0,500.0,14.0122,360.0,500.0,NaN,N +SolarJuice American Inc: S4A-A70 {240V},240,86.2952,6680,7047.85,390,-5.25849e-06,-1.08839e-05,0.000700888,-0.00052983,25.0,500.0,18.0714,280.0,500.0,NaN,N +SolarJuice American Inc: S4A-A76 {240V},240,48.8966,7832,8223.37,375,-2.98068e-06,-4.56175e-05,-0.00242048,-0.00359598,49.5,430.0,21.929,320.0,430.0,NaN,N +SolarJuice American Inc: S4A-A86 {240V},240,47.4759,8613,9035.99,396.5,-2.61282e-06,-4.21776e-05,0.00177193,-0.00158556,42.0,430.0,22.7894,363.0,430.0,NaN,N +SolarJuice American Inc: S4A-H60 {240V},240,76.4939,5570,5867.43,335,-2.70981e-06,-4.25927e-05,0.000676665,-0.0022977,25.0,425.0,17.5147,240.0,425.0,NaN,Y +SolarJuice American Inc: S4A-H70 {240V},240,76.9232,6666,7018.43,360,-2.61451e-06,-4.12138e-05,0.00105761,-0.00230985,25.0,425.0,19.4956,290.0,425.0,NaN,Y +SolarJuice American Inc: S4A-H76 {240V},240,49.2438,7642,7986.08,402,-2.27199e-06,-4.04422e-05,-0.00127208,-0.000949817,44.0,500.0,19.8659,304.0,500.0,NaN,Y +SolarJuice American Inc: S4A-H86 {240V},240,47.3466,8604,9013.82,379,-2.55859e-06,-4.0658e-05,-0.000601146,-0.000323469,40.0,500.0,23.7832,258.0,500.0,NaN,Y +Solaria Corporation: Solaria PowerXT-345R-AC {240V},240,1.94866,290,298.997,36,-6.43023e-05,-0.00028131,0.017354,-0.0310376,0.025,45.0,8.30546,27.0,45.0,2019-05-01 00:00:00,N +Solaria Corporation: Solaria PowerXT-350R-AC {240V},240,1.94866,290,298.997,36,-6.43023e-05,-0.00028131,0.017354,-0.0310376,0.025,45.0,8.30546,27.0,45.0,2019-05-01 00:00:00,N +Solaria Corporation: Solaria PowerXT-355R-AC {240V},240,1.94866,290,298.997,36,-6.43023e-05,-0.00028131,0.017354,-0.0310376,0.025,45.0,8.30546,27.0,45.0,2019-05-01 00:00:00,N +Solaria Corporation: Solaria PowerXT-360R-AC {240V},240,1.94866,290,298.997,36,-6.43023e-05,-0.00028131,0.017354,-0.0310376,0.025,45.0,8.30546,27.0,45.0,2019-05-01 00:00:00,N +Solaria Corporation: Solaria PowerXT-365R-AC {240V},240,1.8874,290,299.066,36,-6.58297e-05,-0.000273767,0.0188955,-0.0278326,0.025,45.0,8.30738,27.0,45.0,NaN,N +Solaria Corporation: Solaria PowerXT-395R-PM-AC {240V},240,1.80212,348.698,361.323,40.5,-5.76212e-05,4.7478e-06,0.00855034,-0.00969625,0.019,43.0,8.92155,38.0,43.0,NaN,N +Solaria Corporation: Solaria PowerXT-400R-PM-AC {240V},240,1.80212,348.698,361.323,40.5,-5.76212e-05,4.7478e-06,0.00855034,-0.00969625,0.019,43.0,8.92155,38.0,43.0,NaN,N +Solaria Corporation: Solaria PowerXT-410R-PM-AC {240V},240,1.80212,348.698,361.323,40.5,-5.76212e-05,4.7478e-06,0.00855034,-0.00969625,0.019,43.0,8.92155,38.0,43.0,NaN,N +Solaria Corporation: Solaria PowerXT-420R-PM-AC {240V},240,1.80212,348.698,361.323,40.5,-5.76212e-05,4.7478e-06,0.00855034,-0.00969625,0.019,43.0,8.92155,38.0,43.0,NaN,N +Solvari Inc: SVR-A10-208 {208V},208,1.80475,303,314.639,35,-7.37266e-05,-3.37761e-06,0.00724539,0.00560634,0.2,55.0,8.98968,22.0,55.0,NaN,N +Solvari Inc: SVR-A10-240 {240V},240,2.03872,346,359.33,35,-7.16321e-05,-7.17456e-05,0.0106436,-0.0035963,0.3,55.0,10.2666,22.0,55.0,NaN,N +Solvari Inc: SVR-A11-208 {208V},208,2.03301,343,356.088,35,-6.33807e-05,5.5941e-06,0.00761511,0.00673959,0.2,55.0,10.174,22.0,55.0,NaN,N +Solvari Inc: SVR-A11-240 {240V},240,2.31239,398,413.381,35,-6.2579e-05,-7.7285e-05,0.0113614,-0.00347656,0.3,55.0,11.8109,22.0,55.0,NaN,N +Sparq Systems: Q1200-4101 {240V},240,11.1883,1165,1203.41,29,-1.99481e-05,-3.08741e-05,0.0589859,0.0196909,0.04,31.0,41.4967,28.0,31.0,2018-10-15 00:00:00,N +Sparq Systems: Q1200-4102 {240V},240,16.8043,1203,1237.28,37,-2.2604e-05,0.000788287,0.025118,0.100027,0.04,38.0,33.44,36.0,38.0,NaN,N +Sparq Systems: Q2000-4102 {240V},240,21.404,1720,1777.45,37.5,-2.23334e-05,-0.00136146,-0.00417842,-0.0247858,0.516,38.5,47.3987,36.5,38.5,NaN,N +Star Charge Americas Corp: SI104LULA00 {208V},208,16.0772,8304,8606.16,360,-2.59225e-06,-6.84834e-06,0.00444795,0.000529211,19.0,480.0,23.906,320.0,480.0,2025-05-21 00:00:00,Y +Star Charge Americas Corp: SI104LULA00 {240V},240,39.6268,9582,9918.19,360,-2.01623e-06,-9.65087e-06,0.00196819,0.000320079,6.26,480.0,27.5505,320.0,480.0,2025-05-21 00:00:00,Y +Star Charge Americas Corp: SI125TULT00 {480V},480,152.723,124382,126289,820,-9.7505e-08,1.43779e-05,0.00358391,-0.000194389,0.33,1000.0,154.011,750.0,1000.0,NaN,N +Star Charge Americas Corp: SI125TULT10 {480V},480,195.648,124346,126231,840,-1.11322e-07,1.28255e-05,0.00502087,0.000566086,0.32,1050.0,150.275,750.0,1050.0,NaN,N +Star Charge Americas Corp: SI135TULT00 {480V},480,125.103,133148,135774,880,-1.05972e-07,5.03472e-06,-0.00685623,-0.00365977,1.78,1050.0,154.289,810.0,1050.0,NaN,N +Star Charge Americas Corp: SI135TULT10 {480V},480,234.731,134288,136561,880,-1.15962e-07,1.3744e-05,0.00358434,0.000431969,0.32,1050.0,155.183,810.0,1050.0,NaN,N +Star Charge Americas Corp: SI403LULA00 {208V},208,24.1492,3315,3401.6,360,-3.94045e-06,-2.56641e-05,0.0017907,0.0013235,19.05,480.0,9.4489,180.0,480.0,2025-05-21 00:00:00,Y +Star Charge Americas Corp: SI403LULA00 {240V},240,47.6885,3811,3925.93,360,-3.08822e-06,-2.75868e-05,0.00119964,0.000791262,6.32,480.0,10.9054,180.0,480.0,2025-05-21 00:00:00,Y +Star Charge Americas Corp: SI803LULA00 {208V},208,19.5923,6635,6852.93,360,-2.90031e-06,-1.89255e-05,0.00264238,0.000381347,6.635,480.0,19.0359,260.0,480.0,2025-05-21 00:00:00,Y +Star Charge Americas Corp: SI803LULA00 {240V},240,42.5566,7641,7893.82,360,-2.24053e-06,-2.20945e-05,0.00142832,3.06121e-05,6.25,480.0,21.9273,260.0,480.0,2025-05-21 00:00:00,Y +Sun Gold Power Inc: SGN-11K15PRO {208V},208,61.6672,11608.8,12035.1,360,-1.50179e-06,-1.82274e-05,-0.000758378,-0.000422684,19.0,480.0,33.4308,200.0,480.0,NaN,Y +Sun Gold Power Inc: SGN-11K15PRO {240V},240,61.3766,11566.9,11979.4,360,-1.50555e-06,-1.78931e-05,-0.000504513,-0.000114654,19.0,480.0,33.276,200.0,480.0,NaN,Y +Sun Gold Power Inc: SGN10KHB-48 {208V},208,54.2796,10185.8,10559.9,360,-1.71331e-06,-1.83926e-05,-0.000737478,-0.000447449,16.94,480.0,29.3331,200.0,480.0,2025-09-02 00:00:00,Y +Sun Gold Power Inc: SGN10KHB-48 {240V},240,54.1553,10147.2,10509.2,360,-1.73518e-06,-1.82368e-05,-0.000687057,-0.000339617,18.0,480.0,29.1921,200.0,480.0,2025-09-02 00:00:00,Y +Sun Gold Power Inc: SGN114KHB-48 {208V},208,53.9638,10185.8,10559.6,360,-1.70231e-06,-1.83095e-05,-0.000762687,-0.000452424,16.94,480.0,29.3323,200.0,480.0,2025-09-02 00:00:00,Y +Sun Gold Power Inc: SGN114KHB-48 {240V},240,54.3165,10139.6,10501,360,-1.72795e-06,-1.82062e-05,-0.000564735,-0.000263705,16.67,480.0,29.1693,200.0,480.0,2025-09-02 00:00:00,Y +Sun Gold Power Inc: SGN76K1HB-48 {208V},208,40.9402,7648,7920.05,360,-2.24833e-06,-2.00774e-05,-0.000791749,-0.000648654,15.0,480.0,22.0002,200.0,480.0,2025-09-02 00:00:00,Y +Sun Gold Power Inc: SGN76K1HB-48 {240V},240,53.1546,7647.2,7921.81,360,-2.84372e-06,-1.81162e-05,-0.00030388,-9.33021e-05,15.0,480.0,22.005,200.0,480.0,2025-09-02 00:00:00,Y +Sun Gold Power Inc: SGS-10K15MAX {208V},208,84.6861,10010,10472.1,362.5,-4.55227e-06,1.14499e-05,-0.000769641,0.000407001,73.0,450.0,28.8886,275.0,450.0,NaN,Y +Sun Gold Power Inc: SGS-10K15MAX {240V},240,89.4158,10010,10448.1,362.5,-3.72674e-06,2.75769e-05,0.00079092,0.00135647,73.7,450.0,28.8224,275.0,450.0,NaN,Y +Sun Gold Power Inc: SGS-12K18MAX {208V},208,77.9024,10400,10901.3,362.5,-4.40278e-06,5.26575e-06,7.44128e-05,0.000241566,71.2,450.0,30.0727,275.0,450.0,NaN,Y +Sun Gold Power Inc: SGS-12K18MAX {240V},240,77.179,11990,12566.8,362.5,-3.42965e-06,-5.05214e-06,-0.000326941,-0.000121808,74.3,450.0,34.6669,275.0,450.0,NaN,Y +Sun Gold Power Inc: SGS-8K12MAX {208V},208,71.3351,8810,9203.03,362.5,-4.43298e-06,3.33512e-05,0.00176484,0.00198885,72.3,450.0,25.3877,275.0,450.0,NaN,Y +Sun Gold Power Inc: SGS-8K12MAX {240V},240,60.2951,8810,9184.93,362.5,-3.53581e-06,1.03286e-05,-0.00110778,-0.000812087,73.1,450.0,25.3377,275.0,450.0,NaN,Y +SunPower: SPR-12000m-3 {480V},480,56.0753,12000,12273.9,675,-7.10206e-07,-3.52678e-05,-0.000324462,-0.00173807,1.79,800.0,18.1836,300.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-12000m-3-H {480V},480,56.0753,12000,12273.9,675,-7.10206e-07,-3.52678e-05,-0.000324462,-0.00173807,1.79,800.0,18.1836,300.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-15000m-3 {480V},480,52.4856,15000,15350.5,675,-5.87211e-07,-3.82472e-05,-0.000300578,-0.00170938,1.79,800.0,22.7414,300.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-15000m-3-H {480V},480,52.4856,15000,15350.5,675,-5.87211e-07,-3.82472e-05,-0.000300578,-0.00170938,1.79,800.0,22.7414,300.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-20000m-3 {480V},480,46.7203,20000,20475.1,695,-6.37674e-07,-3.26817e-05,-0.000483517,-0.000524834,1.79,800.0,29.4605,380.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-20000m-3-H {480V},480,46.7203,20000,20475.1,695,-6.37674e-07,-3.26817e-05,-0.000483517,-0.000524834,1.79,800.0,29.4605,380.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-24000m-3 {480V},480,46.6606,24060,24584.4,712,-4.29422e-07,-3.58971e-05,0.000150953,-0.000900321,1.79,800.0,34.5286,450.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-24000m-3-H {480V},480,46.6606,24060,24584.4,712,-4.29422e-07,-3.58971e-05,0.000150953,-0.000900321,1.79,800.0,34.5286,450.0,800.0,2018-10-15 00:00:00,N +SunPower: SPR-30000m-3 {480V},480,63.0627,30010,30592.4,720,-3.55646e-07,-1.92904e-05,-0.000329177,-0.000275711,1.22,800.0,42.4894,500.0,800.0,2018-10-15 00:00:00,N +Sungrow Power Supply Co Ltd: SC1000KU {540V},540,4775.71,1001306,1.03843e+06,1005,-2.0986e-08,1.24377e-05,0.000819678,0.000287823,83.7646,1200.0,1033.26,810.0,1200.0,NaN,Y +Sungrow Power Supply Co Ltd: SC1200UD-US {480V},480,1217.64,1203052,1.22803e+06,900,-1.02473e-08,3.48137e-06,0.00153223,8.99514e-06,146.929,1500.0,1364.48,700.0,1500.0,2023-02-13 00:00:00,N +Sungrow Power Supply Co Ltd: SC125CX-US {480V},480,193.31,125385,127455,850,-5.17088e-08,1.02118e-05,0.000550288,-0.000952447,18.9,935.0,149.947,767.0,935.0,NaN,N +Sungrow Power Supply Co Ltd: SC125HX-US {690V},690,416.642,127373,129437,1250,-8.94214e-08,5.0262e-06,0.00105024,-0.000845133,4.62,1500.0,103.549,1000.0,1500.0,NaN,N +Sungrow Power Supply Co Ltd: SC1375UD-US {550V},550,1548.24,1378936,1.40468e+06,975,-8.7834e-09,3.16424e-06,0.000353216,-0.000285229,144.254,1500.0,1440.7,800.0,1500.0,2023-02-13 00:00:00,N +Sungrow Power Supply Co Ltd: SC1575UD-US {630V},630,2270.2,1582996,1.61075e+06,1062,-8.3822e-09,3.18995e-06,0.000451809,-0.000102364,144.104,1500.0,1516.71,915.0,1500.0,2023-02-13 00:00:00,N +Sungrow Power Supply Co Ltd: SC1725UD-US {690V},690,2651.48,1728406,1.75684e+06,1125,-7.53778e-09,3.87113e-06,0.000760615,0.000207591,141.725,1500.0,1561.63,1000.0,1500.0,2023-02-13 00:00:00,N +Sungrow Power Supply Co Ltd: SC2000UD-US {800V},800,5003.09,2014870,2.0602e+06,1250,-8.94256e-09,3.30054e-06,0.000436502,-4.42912e-05,157.7,1500.0,1648.16,1150.0,1500.0,NaN,N +Sungrow Power Supply Co Ltd: SC210HX-US {690V},690,534.226,212078,215329,1250,-3.68516e-08,9.9905e-06,0.00233223,0.000982914,5.33,1500.0,172.263,1000.0,1500.0,NaN,N +Sungrow Power Supply Co Ltd: SC2500U {550V},550,8485.63,2507194,2.57916e+06,975,-7.05627e-09,5.56504e-06,0.000106673,-0.000143943,62.8,1500.0,2645.3,800.0,1500.0,2020-03-23 00:00:00,N +Sungrow Power Supply Co Ltd: SC2500UD-US {900V},900,6066.41,2507230,2.5637e+06,1350,-8.03897e-09,3.22933e-06,0.000485948,4.84988e-05,169.9,1500.0,1899.04,1300.0,1500.0,NaN,N +Sungrow Power Supply Co Ltd: SC250KU {480V},480,1091.79,250000,261135,675,-8.56121e-08,6.8032e-06,0.00153289,-0.000500047,93.64,850.0,386.866,500.0,850.0,2021-09-13 00:00:00,N +Sungrow Power Supply Co Ltd: SC60HV {480V},480,164.592,66000,67413.2,850,-1.66958e-07,1.40636e-05,0.00190885,0.000305414,0.26,1300.0,79.3096,700.0,1300.0,2023-02-13 00:00:00,N +Sungrow Power Supply Co Ltd: SC75HV {600V},600,208.52,82500,84179.5,1000,-1.34653e-07,1.57798e-05,0.00259869,0.00100434,5.35,1300.0,84.1795,870.0,1300.0,2020-10-12 00:00:00,N +Sungrow Power Supply Co Ltd: SG125HV {600V},600,97.9892,125000,127418,945,-8.60718e-08,1.83602e-05,0.00417508,0.0024596,5.59,1200.0,134.834,860.0,1200.0,2022-01-21 00:00:00,N +Sungrow Power Supply Co Ltd: SG200HX-US {600V},600,336.316,200444,204058,1000,-4.80697e-08,-6.80102e-08,9.44394e-05,0.000104433,4.54,1300.0,204.058,850.0,1300.0,NaN,N +Sungrow Power Supply Co Ltd: SG2500U {550V},550,3909.58,2500000,2.5425e+06,900,-3.86442e-09,4.99122e-06,0.000281378,-0.000497697,651.36,1200.0,2825,800.0,1200.0,2018-10-15 00:00:00,N +Sungrow Power Supply Co Ltd: SG250HX-US {800V},800,443.342,226997,230396,1080,-4.38534e-08,-8.57136e-06,-0.000791432,-0.000320827,5.21,1300.0,213.33,860.0,1300.0,2021-02-22 00:00:00,Y +Sungrow Power Supply Co Ltd: SG3150U {630V},630,10438.2,3154300,3.23555e+06,1120,-4.76658e-09,4.5644e-06,0.000345361,0.000191243,270.2,1300.0,2888.88,915.0,1300.0,NaN,N +Sungrow Power Supply Co Ltd: SG3150UD-MV-US {600V},600,3201.8,1053000,1.08551e+06,1100,-2.2644e-08,2.61566e-06,0.00038814,-3.45764e-05,124.76,1438.0,986.828,875.0,1438.0,2024-04-11 00:00:00,Y +Sungrow Power Supply Co Ltd: SG3425UD {600V},600,6564.65,3434560,3.53137e+06,1100,-4.84356e-09,3.59679e-06,8.38644e-05,-8.86344e-05,256.66,1300.0,3210.34,875.0,1300.0,2023-03-21 00:00:00,N +Sungrow Power Supply Co Ltd: SG350HX-US {800V},800,426.312,320865,326477,1180,-3.19849e-08,-8.53203e-06,-0.00123391,-0.000245992,4.83,1330.0,276.676,860.0,1330.0,2024-01-02 00:00:00,N +Sungrow Power Supply Co Ltd: SG3600UD {630V},630,7573.76,3606980,3.70831e+06,1100,-4.73641e-09,3.04621e-06,0.000146485,-9.50686e-05,264.05,1300.0,3371.19,915.0,1300.0,2023-03-21 00:00:00,N +Sungrow Power Supply Co Ltd: SG4400UD-MV-US {645V},645,3271.79,1103000,1.1357e+06,1100,-2.0961e-08,3.63901e-06,0.000214197,-8.23416e-05,128.74,1449.0,1032.46,915.0,1449.0,2024-04-11 00:00:00,Y +Sungrow Power Supply Co Ltd: SG60KU-M {480V},480,117.382,60000,61033.9,700,-1.80969e-07,-1.17151e-05,-0.000326777,-0.000743109,0.88,850.0,87.1913,550.0,850.0,2019-06-03 00:00:00,N +Sungrow: SG36CX-US {480V},480,98.7367,36046,36785.9,710,-2.75465e-07,-2.20492e-05,-0.000393522,-0.00108353,3.7,850.0,51.8112,550.0,850.0,2024-09-23 00:00:00,N +Sungrow: SG60CX-US {480V},480,112.534,60182,61436,710,-1.94741e-07,-1.72498e-05,-0.000921977,-0.000582085,3.38,850.0,86.5296,550.0,850.0,2024-09-23 00:00:00,N +Suzhou Ample ESS Co Ltd: AP-L10K-SPUS {240V},240,50.6752,10010.9,10362.7,380,-1.11564e-06,-6.61416e-05,-0.000452633,-0.00267001,10.12,480.0,27.2703,135.0,480.0,NaN,Y +Suzhou Ample ESS Co Ltd: AP-L12K-SPUS {240V},240,47.5069,12014.5,12447.4,380,-1.2097e-06,-6.21825e-05,-0.00131057,-0.0021937,10.39,480.0,32.7563,161.0,480.0,NaN,Y +Suzhou Ample ESS Co Ltd: AP-L15K-SPUS {240V},240,49.0214,15014.8,15596.5,380,-1.2472e-06,-5.40958e-05,-0.00144971,-0.00136986,10.08,480.0,41.0434,202.0,480.0,NaN,Y +Suzhou Ample ESS Co Ltd: AP-L8K-SPUS {240V},240,51.452,7981.39,8255.49,380,-1.52067e-06,-7.70681e-05,-0.000266768,-0.00307047,10.39,480.0,21.725,108.0,480.0,NaN,Y +TMEIC Corporation: PVU-L0840URN {630V},630,2180.91,796468,808497,986,-5.27238e-09,8.673e-06,0.000526054,-3.00804e-06,76.9288,1200.0,819.976,915.0,1200.0,NaN,N +TMEIC: PVU-L0840GR {630V},630,2424.5,794693,808119,1150,1.76259e-09,1.80311e-05,0.00045847,-0.00638838,47.17,1200.0,702.712,915.0,1200.0,NaN,N +TRUMPF Httinger GmbH + Co KG: TruConvert AC 3025 {480V},480,129.459,24967.9,25698.6,867,-3.92186e-07,2.63653e-05,0.00265583,0.0011015,10.0,950.0,29.6409,784.0,950.0,NaN,N +TSUNESS Co Ltd: TSOL-M1600P {240V},240,3.91094,1551,1609.53,42,-5.37041e-06,-0.000546252,-0.07683,-0.231669,0.03,48.0,38.3221,36.0,48.0,NaN,N +Tabuchi Electric Co Ltd: THD-S55P3B-US {240V},240,48.9881,5518.92,5821.88,380,-3.53275e-06,-3.02891e-05,0.00125039,0.0005731,10.1,520.0,15.3207,240.0,520.0,2018-10-15 00:00:00,Y +Tabuchi Electric Co Ltd: THD-S55P3BB-US {240V},240,48.9881,5518.92,5821.88,380,-3.53275e-06,-3.02891e-05,0.00125039,0.0005731,10.1,520.0,15.3207,240.0,520.0,2018-10-15 00:00:00,Y +Tabuchi Electric Co Ltd: THE-S55P3BB-USW {240V},240,48.5544,5518.92,5822.06,380,-3.44822e-06,-3.2012e-05,0.0012911,0.000498217,10.1,520.0,15.3212,240.0,520.0,2018-10-15 00:00:00,Y +Tesla Inc: 1534000-xx-y {208V},208,14.2169,3336,3424.52,375,-1.9777e-06,-2.66307e-05,-0.00163408,-0.00869451,3.8925,480.0,9.13207,270.0,480.0,2023-01-03 00:00:00,N +Tesla Inc: 1534000-xx-y {240V},240,27.9577,3800,3893.19,350,-5.71836e-06,-4.76088e-05,0.000704879,-0.00156571,4.664,425.0,11.1234,270.0,425.0,2023-01-03 00:00:00,N +Tesla Inc: 1538000-xx-y {208V},208,31.8324,6561,6738.25,375,-2.89466e-06,-9.77654e-06,-0.000357555,-0.00271309,6.7176,480.0,17.9687,270.0,480.0,2023-01-03 00:00:00,N +Tesla Inc: 1538000-xx-y {240V},240,41.1225,7575,7766.37,375,-3.54741e-06,-2.0776e-05,-0.00140648,-0.00210321,6.913,480.0,20.7103,270.0,480.0,2024-06-03 00:00:00,N +Tesla Inc: 1707000-XX-Y {240V 10kW},240,99.8569,9991,10426.5,375,-3.23235e-06,8.72632e-05,0.00158558,0.0017987,0.11,480.0,27.804,270.0,480.0,NaN,Y +Tesla Inc: 1707000-XX-Y {240V 115kW},240,117.516,11508,11841,375,-2.66362e-06,-3.12624e-05,0.000902567,-0.00168436,0.29,480.0,31.576,270.0,480.0,NaN,Y +Tigo Energy Inc: TSI-100K-US {208V},208,29.0146,8760,9007.98,380,-1.28698e-06,-4.15848e-05,0.000622295,5.72289e-05,10.0,480.0,23.7052,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-100K-US {240V},240,39.5146,10082,10328.5,380,-1.31953e-06,-4.36227e-05,0.000405515,-0.000846426,10.0,480.0,27.1802,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-114K-US {208V},208,31.1947,10040,10308,380,-9.16002e-07,-3.559e-05,0.000574569,-0.00113531,10.0,480.0,27.1264,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-114K-US {240V},240,41.2688,11520,11783.5,380,-1.09624e-06,-1.63085e-05,0.00014452,-2.54053e-05,10.0,480.0,31.0093,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-30K-US {208V},208,17.196,2626,2713.68,380,-4.99411e-06,-4.14824e-05,-0.00096125,-0.00156266,1.576,480.0,7.14127,125.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-30K-US {240V},240,16.9589,3095,3184.22,380,-3.75554e-06,-3.82152e-05,-0.000858481,-0.00160756,1.593,480.0,8.37954,125.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-38K-US {208V},208,24.4723,3324,3418.64,380,-4.39358e-06,-4.32261e-05,-0.000212206,-0.00036273,1.576,480.0,8.99641,160.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-38K-US {240V},240,19.9959,3888,3987.16,380,-2.96039e-06,-4.18045e-05,-0.000716973,-0.000643354,1.593,480.0,10.4925,160.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-50K-US {208V},208,20.0951,4280,4401.03,380,-3.80382e-06,-3.8371e-05,-0.00161675,-0.00216058,1.576,480.0,11.5816,210.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-50K-US {240V},240,21.1886,4943,5075.82,380,-3.22302e-06,-4.7108e-05,-0.000573923,-0.000712923,1.593,480.0,13.3574,210.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-60K-US {208V},208,24.8637,5143,5303.07,380,-3.36204e-06,-3.41204e-05,-0.000145404,0.00104586,1.576,480.0,13.9554,170.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-60K-US {240V},240,23.0661,5918,6084.58,380,-2.3168e-06,-4.22293e-05,-0.00156567,0.000104517,1.593,480.0,16.0121,170.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-76K-US {208V},208,32.4639,6580,6776.33,380,-2.44481e-06,-3.25023e-05,-0.000582189,-0.000967108,1.576,480.0,17.8325,212.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-76K-US {240V},240,35.2212,7524,7741.49,380,-2.91717e-06,-3.67176e-05,-0.000401827,-0.000518179,1.593,480.0,20.3723,212.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-82K-US {208V},208,34.3674,7166,7356.19,380,-1.61392e-06,-3.93032e-05,0.00084191,0.000469394,10.0,480.0,19.3584,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-82K-US {240V},240,42.4825,8251,8445.17,380,-1.52261e-06,-3.89029e-05,0.000360027,-0.000552598,10.0,480.0,22.2241,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-90K-US {208V},208,33.0697,7874,8087.05,380,-1.47764e-06,-3.73932e-05,-0.000147108,-0.000661754,10.0,480.0,21.2817,250.0,480.0,2023-10-11 00:00:00,Y +Tigo Energy Inc: TSI-90K-US {240V},240,41.617,9063,9277.47,380,-1.37093e-06,-4.1912e-05,0.00028924,-0.000637612,10.0,480.0,24.4144,250.0,480.0,2023-10-11 00:00:00,Y +Trystar LLC: OZPCS-EP40-000 {208V},208,257.407,17229.9,18280.6,700,-2.02598e-06,-3.67337e-05,-0.00118837,7.58259e-05,8.96,820.0,26.1152,550.0,820.0,NaN,N +Trystar LLC: OZPCS-EP40-000 {480V},480,178.364,39540,40858.1,700,-4.01874e-07,-2.95236e-05,-0.00272352,-0.00108784,25.79,820.0,58.3686,550.0,820.0,NaN,N +Trystar LLC: OZPCS-RS35-FB0 {208V},208,314.162,34331.7,36062.7,600,-6.31471e-07,2.36281e-05,0.00264339,1.30657e-05,2.14,800.0,60.1045,400.0,800.0,NaN,N +Trystar LLC: OZPCS-RS35-FB0 {240V},240,247.993,23446.3,24639.5,600,-9.44695e-07,3.00355e-05,0.00240062,7.12807e-05,1.41,800.0,41.0658,400.0,800.0,NaN,N +Trystar LLC: OZPCS-RS35-FB1 {208V},208,314.162,34331.7,36062.7,600,-6.31471e-07,2.36281e-05,0.00264339,1.30657e-05,2.14,800.0,60.1045,400.0,800.0,NaN,N +Trystar LLC: OZPCS-RS35-FB1 {240V},240,247.993,23446.3,24639.5,600,-9.44695e-07,3.00355e-05,0.00240062,7.12807e-05,1.41,800.0,41.0658,400.0,800.0,NaN,N +Trystar LLC: OZPCS-RS40-BB1 {208V},208,257.407,17229.9,18280.6,700,-2.02598e-06,-3.67337e-05,-0.00118837,7.58259e-05,8.96,820.0,26.1152,550.0,820.0,NaN,N +Trystar LLC: OZPCS-RS40-BB1 {480V},480,178.364,39540,40858.1,700,-4.01874e-07,-2.95236e-05,-0.00272352,-0.00108784,25.79,820.0,58.3686,550.0,820.0,NaN,N +Trystar LLC: OZPCS-RS40-Bxx {208V},208,357.943,17516,18604.3,700,-2.07155e-06,-3.58802e-05,-0.00162412,-0.000874908,191.36,820.0,26.5776,550.0,820.0,2024-04-02 00:00:00,N +Trystar LLC: OZPCS-RS40-Bxx {480V},480,371.098,39913,41119.4,700,-4.29755e-07,-3.09941e-05,-0.00148289,-0.00152964,1066.26,820.0,58.742,550.0,820.0,2024-04-02 00:00:00,N +Trystar LLC: OZPCS-RS40-FB1 {208V},208,257.407,17229.9,18280.6,700,-2.02598e-06,-3.67337e-05,-0.00118837,7.58259e-05,8.96,820.0,26.1152,550.0,820.0,NaN,N +Trystar LLC: OZPCS-RS40-FB1 {480V},480,178.364,39540,40858.1,700,-4.01874e-07,-2.95236e-05,-0.00272352,-0.00108784,25.79,820.0,58.3686,550.0,820.0,NaN,N +Trystar LLC: OZPCS-RS40-Fxx {208V},208,336.097,17515,18660.2,700,-1.73142e-06,-3.36704e-05,-0.00183411,-0.000948352,202.52,820.0,26.6574,550.0,820.0,2024-04-02 00:00:00,N +Trystar LLC: OZPCS-RS40-Fxx {480V},480,397.566,39894,41252.2,700,-4.41728e-07,-3.19482e-05,-0.0010877,-0.000685147,1105.1,820.0,58.9317,550.0,820.0,2024-04-02 00:00:00,N +Univix Power Solutions: UVX10KLNA {240V},240,51.9686,10000,10292,360,-1.26033e-06,-2.02581e-05,-5.21533e-05,-0.000766056,33.64,430.0,28.5888,280.0,430.0,NaN,Y +Univix Power Solutions: UVX12KLNA {240V},240,51.8788,12000,12474,360,-1.35354e-06,-3.87402e-05,0.00232624,0.00357488,13.202,430.0,34.65,200.0,430.0,NaN,Y +Univix Power Solutions: UVX16LNA {240V},240,67.3029,16000,16621.2,360,-8.96976e-07,-1.28542e-05,0.00529846,0.00964609,20.465,430.0,46.1701,220.0,430.0,NaN,Y +Univix Power Solutions: UVX5KLNA {240V},240,29.3587,5000,5153.82,360,-3.6512e-06,-1.5292e-05,0.000125821,0.000551915,22.6,430.0,14.3162,180.0,430.0,NaN,Y +Univix Power Solutions: UVX6KLNA {240V},240,33.6679,6000,6175.94,360,-2.58712e-06,-2.0188e-05,0.000191477,-0.0002564,22.99,430.0,17.1554,200.0,430.0,NaN,Y +Univix Power Solutions: UVX76KLNA {240V},240,37.4864,7600,7822.08,360,-1.60481e-06,-2.17675e-05,-0.000935129,-0.00139184,30.71,430.0,21.728,220.0,430.0,NaN,Y +Univix Power Solutions: UVX8KLNA {240V},240,65.6455,8000,8238.7,360,-2.93482e-06,-5.61514e-06,-0.000923485,-0.00173197,17.4,430.0,22.8853,250.0,430.0,NaN,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {120V},120,79.4493,9018.6,9411.59,360,-1.29986e-06,-4.88046e-06,0.00204238,-0.000538941,4.0,500.0,26.1433,285.0,500.0,2024-11-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Optimum {240V},240,79.4493,9018.6,9411.59,360,-1.29986e-06,-4.88046e-06,0.00204238,-0.000538941,4.0,500.0,26.1433,285.0,500.0,2024-11-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Premium {120V},120,80.5448,10029,10565.2,360,-2.37521e-06,4.73666e-06,0.0025683,0.00129743,4.0,500.0,29.3478,285.0,500.0,2024-11-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP 12KW Premium {240V},240,80.5448,10029,10565.2,360,-2.37521e-06,4.73666e-06,0.0025683,0.00129743,4.0,500.0,29.3478,285.0,500.0,2024-11-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP LV 12KW {120V},120,79.4493,9018.6,9411.59,360,-1.29986e-06,-4.88046e-06,0.00204238,-0.000538941,4.0,500.0,26.1433,285.0,500.0,2024-11-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP LV 12KW {240V},240,79.4493,9018.6,9411.59,360,-1.29986e-06,-4.88046e-06,0.00204238,-0.000538941,4.0,500.0,26.1433,285.0,500.0,2024-11-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP LV 6KW {120V},120,108.831,6017.66,6365.36,370,-2.94294e-06,5.26104e-06,0.00113353,-0.000448432,43.0,500.0,17.2037,250.0,500.0,2025-05-01 00:00:00,Y +VOLTRONIC POWER TECHNOLOGY (SHENZHEN) CORP: InfiniSolar WP LV 6KW {240V},240,156.592,6000,6536.64,370,-6.03042e-06,-1.00594e-05,0.00129672,-0.0013688,15.0,500.0,17.6666,250.0,500.0,NaN,Y +WSTECH GmbH: APS1600-ES-2-440-5 {440V},440,3637.56,1626952,1.66884e+06,1000,-1.06358e-08,1.01317e-05,0.000807706,0.000219106,91.4,1500.0,1668.84,648.0,1500.0,NaN,N +WSTECH GmbH: APS1600-PV-2-440-5 {440V},440,3637.56,1626952,1.66884e+06,1000,-1.06358e-08,1.01317e-05,0.000807706,0.000219106,91.4,1500.0,1668.84,648.0,1500.0,NaN,N +WSTECH GmbH: APS1740-ES-2-480-5 {480V},480,6885.14,1735360,1.7812e+06,1000,-9.74875e-09,7.85931e-06,0.000593218,-4.74175e-05,91.402,1470.0,1781.2,770.0,1470.0,NaN,N +WSTECH GmbH: APS1740-PV-2-480-5 {480V},480,6885.14,1735360,1.7812e+06,1000,-9.74875e-09,7.85931e-06,0.000593218,-4.74175e-05,91.402,1470.0,1781.2,770.0,1470.0,NaN,N +WSTECH GmbH: APS800-ES-1-440-5 {440V},440,1992.13,814167,837619,1000,-2.30173e-08,4.29104e-06,3.90641e-05,-0.000116885,91.4,1500.0,837.619,648.0,1500.0,NaN,N +WSTECH GmbH: APS800-PV-1-440-5 {440V},440,1992.13,814167,837619,1000,-2.30173e-08,4.29104e-06,3.90641e-05,-0.000116885,91.4,1500.0,837.619,648.0,1500.0,NaN,N +WSTECH GmbH: APS870-ES-1-480-5 {480V},480,2670.89,872029,893886,1000,-1.98485e-08,8.29956e-06,-0.000394822,-0.000131325,91.402,1470.0,893.886,770.0,1470.0,NaN,N +WSTECH GmbH: APS870-PV-1-480-5 {480V},480,2670.89,872029,893886,1000,-1.98485e-08,8.29956e-06,-0.000394822,-0.000131325,91.402,1470.0,893.886,770.0,1470.0,NaN,N +Wanbang Digital Energy Co Ltd: SI104LULA00 {208V},208,17.7832,8323,8624.43,360,-2.57007e-06,-5.68654e-06,0.00322164,0.00027298,5.03,480.0,23.9568,320.0,480.0,NaN,Y +Wanbang Digital Energy Co Ltd: SI104LULA00 {240V},240,41.0184,9580,9913.76,360,-2.03969e-06,-9.86067e-06,0.00187306,0.000275133,5.42,480.0,27.5382,320.0,480.0,NaN,Y +Xiamen Kehua Digital Energy Tech Co Ltd: BCS100K-B-HM-US X2 {480V},480,145.12,100073,101871,1010,-1.06203e-07,3.56746e-06,0.000466329,0.000326504,60.8,1300.0,100.862,720.0,1300.0,NaN,N +Xiamen Kehua Digital Energy Tech Co Ltd: BCS125K-B-HM-US X2 {480V},480,77.2525,125015,127090,1010,-4.19985e-08,3.3925e-06,0.00125611,0.000507251,60.0,1300.0,125.832,720.0,1300.0,NaN,N +Xiamen Kehua Digital Energy Tech Co Ltd: BCS150K-B-HM-US X2 {600V},600,102.895,150015,152526,1185,-3.78567e-08,2.56342e-06,0.00149188,0.000320418,62.4,1450.0,128.714,920.0,1450.0,NaN,N +Xiamen Kehua Digital Energy Tech Co Ltd: BCS175K-B-HM-US X2 {600V},600,155.951,175017,177969,1185,-3.73344e-08,2.87351e-06,0.00121863,0.000268159,64.4,1450.0,150.184,920.0,1450.0,NaN,N +Xiamen Kehua Digital Energy Tech Co Ltd: BCS75K-B-HM-US X2 {480V},480,72.014,75084.4,76350.1,1080,-9.09261e-08,2.15143e-06,0.00111768,0.000360339,62.1,1450.0,70.6945,720.0,1450.0,NaN,N +Xiamen Kehua Digital Energy Tech Co Ltd: iStoragE2A 10000 {240V},240,40.5923,9956.3,10242.6,370,-8.49006e-07,-1.75184e-05,-0.00105652,0.000474221,2.5,440.0,27.6827,300.0,440.0,NaN,Y +Xiamen Kehua Digital Energy Tech Co Ltd: iStoragE2A 11400 {240V},240,43.9192,11370.5,11712.2,370,-1.08732e-06,-1.40766e-05,-0.0011544,0.000505528,2.5,440.0,31.6545,300.0,440.0,NaN,Y +Xiamen Kehua Digital Energy Tech Co Ltd: iStoragE2A 12000 {240V},240,46.7423,11968.2,12332.9,370,-1.11762e-06,-1.33789e-05,-0.00104383,0.000740904,2.5,440.0,33.3322,300.0,440.0,NaN,Y +Xiamen Kehua Digital Energy Tech Co Ltd: iStoragE2A 7600 {240V},240,32.785,7581.02,7787.78,370,-5.09915e-07,-2.14715e-05,-0.0010367,-0.000972918,2.5,440.0,21.0481,300.0,440.0,NaN,Y +Xiamen Kehua Digital Energy Tech Co Ltd: iStoragE2A 9600 {240V},240,40.872,9573.26,9845.35,370,-8.35392e-07,-1.67424e-05,-0.000562285,0.00138071,2.5,440.0,26.609,300.0,440.0,NaN,Y +Xiamen Kehua Hengsheng Co Ltd: SPI50K-BHV {480V},480,125.023,49825,50827.9,695,-1.87965e-07,-1.33433e-05,0.00138134,0.00284234,2.8,850.0,73.1337,540.0,850.0,2018-10-15 00:00:00,N +Xiamen Kehua Hengsheng Co Ltd: SPI60K-BHV {480V},480,76.6969,59668,60955.1,695,-1.80672e-07,-1.90869e-05,-0.00171842,-0.000358674,2.8,850.0,87.7052,540.0,850.0,2018-10-15 00:00:00,N +Yaskawa Solectria Solar: PVI 25TL-208 {208V},208,79.0356,25000,25971.3,575,-6.61542e-07,1.5913e-05,0.00180454,0.000250856,2.9,850.0,45.1676,480.0,850.0,2022-09-01 00:00:00,N +Yaskawa Solectria Solar: PVI 36TL-480 {480V},480,80.1024,36000,36701.7,730,-2.33292e-07,-3.88036e-05,-0.0027293,-0.00119439,10.8,800.0,50.2763,540.0,800.0,2021-02-01 00:00:00,N +Yaskawa Solectria Solar: PVI 50TL-480 {480V},480,96.1458,50000,50831.5,730,-1.44391e-07,-2.42776e-05,-0.00361241,-0.00128939,0.88,850.0,69.6321,480.0,850.0,2022-09-01 00:00:00,N +Yaskawa Solectria Solar: PVI 60TL-480 {480V},480,96.2303,60000,61067.7,730,-1.5132e-07,-2.46471e-05,-0.00371424,-0.00174062,0.88,850.0,83.6544,540.0,850.0,2022-09-01 00:00:00,N +Yaskawa Solectria Solar: PVI-100TL-480 {480V},480,195.947,100000,101978,720,-9.02014e-08,-2.42851e-05,-0.00113853,-0.000624912,21.54,850.0,141.636,340.0,850.0,NaN,N +Yaskawa Solectria Solar: PVI-36TL-480-V2 {480V},480,164.186,36000,36877.4,625,-1.6533e-07,-2.49051e-05,-0.000652284,-0.00119063,2.9,850.0,59.0038,400.0,850.0,NaN,N +Yaskawa Solectria Solar: PVI-50TL-208 {208V},208,120.91,50000,52124.2,380,-4.32437e-07,-3.56836e-06,0.000144318,-0.000334529,50.118,700.0,137.169,200.0,700.0,NaN,N +Yaskawa Solectria Solar: PVI20TL-480-R {480V},480,29.0146,20000,20437.4,735,-4.90504e-07,-2.78694e-05,-0.00177009,-0.00227291,3.0,850.0,27.806,560.0,850.0,2021-04-12 00:00:00,N +Yaskawa Solectria Solar: PVI25TL-480-R {480V},480,37.6542,25000,25548.1,735,-4.0067e-07,-2.67278e-05,-0.00141828,-0.00199184,3.0,850.0,34.7593,560.0,850.0,2023-05-01 00:00:00,N +Yaskawa Solectria Solar: SGI 500XTM {380V},380,2725.47,507000,522637,615,-1.81149e-08,1.11794e-05,0.000884631,-0.000339117,88.78,820.0,849.817,545.0,820.0,NaN,N +Yaskawa Solectria Solar: SGI 750XTM {380V},380,3714.14,753200,777216,615,-1.40704e-08,6.34566e-06,0.00155414,-0.000271668,122.55,820.0,1263.77,545.0,820.0,NaN,N +Yaskawa Solectria Solar: XGI 1500 175-480 {480V},480,83.4808,175000,178408,1100,-3.56825e-08,-8.46648e-07,0.00600063,-0.000256805,0.25,1250.0,162.19,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500 200/200-480 {480V},480,84.2407,200000,203303,1100,-1.74426e-08,-2.49726e-05,0.00223644,-0.0101009,0.25,1250.0,184.821,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500 225-600 {600V},600,260.225,225000,228974,1100,-4.08888e-08,8.39341e-06,0.00169316,0.000116985,0.25,1250.0,208.158,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500 250/250-600 {600V},600,293.042,250000,254813,1100,-4.42477e-08,1.18928e-05,0.00193515,0.000775393,0.33,1250.0,231.648,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-050MW-600 {600V},600,3697.49,500000,506803,1100,-1.93495e-08,1.67932e-05,0.00242043,0.0011556,36.85,1250.0,460.73,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-075MW-600 {600V},600,5104.46,750000,760032,1100,-1.09249e-08,1.40511e-05,0.00152284,0.000667425,36.85,1250.0,690.938,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-085MW-600 {600V},600,6290.5,850000,862104,1100,-1.40112e-08,1.9458e-05,0.00214064,0.00136117,36.85,1250.0,783.731,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-099MW-600 {600V},600,6155.85,999000,1.01453e+06,1100,-1.18337e-08,2.09399e-05,0.00184691,0.000973314,36.85,1250.0,922.303,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-125/125-3S {600V},600,214.518,125000,126773,1000,-1.58888e-08,1.1274e-05,0.00260126,0.010587,0.33,1250.0,126.773,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-125/125-UL {600V},600,214.694,125000,126773,1000,-1.58757e-08,1.12599e-05,0.00260126,0.0105871,2.75,1250.0,126.773,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-125/125-UL-A {600V},600,215.141,125000,126773,1000,-1.59534e-08,1.1245e-05,0.00259663,0.01054,0.33,1250.0,126.773,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-125/150-UL {600V},600,214.694,125000,126773,1000,-1.58757e-08,1.12599e-05,0.00260126,0.0105871,0.33,1250.0,126.773,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-125/150-UL-A {600V},600,215.141,125000,126773,1000,-1.59534e-08,1.1245e-05,0.00259663,0.01054,0.33,1250.0,126.773,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-150/166-UL {600V},600,112.681,150000,152321,1000,-3.20664e-08,1.30668e-05,-0.000350912,-0.000382633,2.75,1250.0,152.321,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-150/166-UL-A {600V},600,113.104,150000,152320,1000,-3.22405e-08,1.30491e-05,-0.000357553,-0.000391813,0.33,1250.0,152.32,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-166/166-3S {600V},600,239.644,166000,168586,1000,-3.83803e-08,1.85871e-05,0.00020601,-0.00151873,0.33,1250.0,168.586,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-166/166-UL {600V},600,239.729,166000,168586,1000,-3.83668e-08,1.85907e-05,0.000206008,-0.00151873,2.75,1250.0,168.586,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-166/166-UL-A {600V},600,238.51,166000,168581,1000,-3.79524e-08,1.8704e-05,0.000193381,-0.00151306,0.33,1250.0,168.581,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-175-480-DCG {480V},480,48.2336,175000,178415,1000,-3.59495e-08,-1.56918e-07,0.0100609,-0.000166557,0.25,1250.0,178.415,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-1MW-600 {600V},600,6170.69,1000000,1.01554e+06,1100,-1.18052e-08,2.09386e-05,0.00184691,0.000973314,36.85,1250.0,923.219,860.0,1250.0,NaN,Y +Yaskawa Solectria Solar: XGI 1500-200/200-480-DCG {480V},480,72.5877,200000,203610,1000,-2.82148e-08,-2.08055e-05,0.0025834,-0.00522736,0.33,1250.0,203.61,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-225-600-DCG {600V},600,228.784,225000,228850,1000,-4.00863e-08,7.45804e-06,0.00206337,0.00025913,0.33,1250.0,228.85,860.0,1250.0,NaN,N +Yaskawa Solectria Solar: XGI 1500-250/250-600-DCG {600V},600,250.11,250000,254620,1000,-4.17759e-08,1.12818e-05,0.00244858,0.000926245,0.33,1250.0,254.62,860.0,1250.0,NaN,N +Yotta Energy Inc: DPI-208 {208V},208,16.0257,1733,1813.38,38,-1.75149e-05,0.000246838,0.01273,-0.00788986,0.087,42.0,47.7204,34.0,42.0,2023-07-21 00:00:00,N +Yotta Energy Inc: DPI-480 {480V},480,9.2364,1821,1896.44,38,6.83257e-07,0.00123179,-0.010247,0.54952,0.2248,42.0,49.9063,34.0,42.0,2023-07-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-H-HSPA {240V},240,22.2539,11147,11601.7,350,-2.33259e-07,5.98804e-05,0.0115571,0.0719172,3.05,500.0,33.1477,200.0,500.0,NaN,Y +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-S {208V},208,3.77972,993.798,1031.41,42,-1.45368e-05,-0.000579872,-0.0574102,-0.114503,0.11,50.0,24.5575,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-S {240V},240,2.18319,1062.16,1102.64,42,-8.60852e-06,-1.81407e-05,0.0791447,0.0821128,0.13,50.0,26.2534,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-S-NA {208V},208,1.41593,962,999.572,42,-4.41104e-06,-0.000473346,0.0267218,-0.267604,0.3,50.0,23.7993,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-S-NA {240V},240,3.4485,958,1003.39,42,-2.7991e-05,-0.000293633,-0.0379677,-0.0387857,0.5,50.0,23.8903,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-SW {208V},208,3.77972,993.798,1031.41,42,-1.45368e-05,-0.000579872,-0.0574102,-0.114503,0.11,50.0,24.5575,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-SW {240V},240,2.18319,1062.16,1102.64,42,-8.60852e-06,-1.81407e-05,0.0791447,0.0821128,0.13,50.0,26.2534,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-SW-NA {208V},208,1.41593,962,999.572,42,-4.41104e-06,-0.000473346,0.0267218,-0.267604,0.3,50.0,23.7993,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1000-SW-NA {240V},240,3.4485,958,1003.39,42,-2.7991e-05,-0.000293633,-0.0379677,-0.0387857,0.5,50.0,23.8903,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1800-S-NA {208V},208,8.68059,1655,1726.46,42,-8.39653e-06,-0.000158891,0.0199724,-0.0105538,0.1,50.0,41.1063,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M1800-SW-NA {208V},208,8.68059,1655,1726.46,42,-8.39653e-06,-0.000158891,0.0199724,-0.0105538,0.1,50.0,41.1063,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M2000-S-NA {208V},208,12.4182,1914,2000.08,42,-2.22927e-05,-0.00130631,-0.0120723,-0.0625248,0.026,50.0,47.6209,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M2000-S-NA {240V},240,2.95147,1910,1993.05,42,-2.2765e-06,7.93718e-05,0.0102981,0.0370584,0.034,50.0,47.4536,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M2000-SW-NA {208V},208,12.4182,1914,2000.08,42,-2.22927e-05,-0.00130631,-0.0120723,-0.0625248,0.026,50.0,47.6209,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M2000-SW-NA {240V},240,2.95147,1910,1993.05,42,-2.2765e-06,7.93718e-05,0.0102981,0.0370584,0.034,50.0,47.4536,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M400-S-NA {208V},208,1.27669,366,383.402,42,-3.45209e-05,-0.000110242,0.0406798,0.0277301,0.014,50.0,9.12862,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M400-S-NA {240V},240,0.766937,367,384.802,42,-1.35405e-05,-0.00061284,0.102107,0.0166083,0.02,50.0,9.16194,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M400-SW-NA {208V},208,1.27669,366,383.402,42,-3.45209e-05,-0.000110242,0.0406798,0.0277301,0.014,50.0,9.12862,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M400-SW-NA {240V},240,0.766937,367,384.802,42,-1.35405e-05,-0.00061284,0.102107,0.0166083,0.02,50.0,9.16194,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M500-S-NA {208V},208,0.924528,478,501.784,42,-2.10045e-05,0.000105376,0.0434029,0.0379819,0.008,50.0,11.9472,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M500-S-NA {240V},240,1.05576,479,500.408,42,-1.97171e-05,0.000132738,0.117442,0.163522,0.03,50.0,11.9145,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {208V},208,0.924528,478,501.784,42,-2.10045e-05,0.000105376,0.0434029,0.0379819,0.008,50.0,11.9472,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M500-SW-NA {240V},240,1.05576,479,500.408,42,-1.97171e-05,0.000132738,0.117442,0.163522,0.03,50.0,11.9145,35.0,50.0,2025-03-21 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-S {208V},208,0.86003,608.36,630.459,42,-2.32767e-06,0.000316398,-0.0699173,0.213159,0.2,50.0,15.0109,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-S {240V},240,2.9217,604.12,628.5,42,-3.59975e-05,0.000363837,-0.0744662,-0.0802006,0.7,50.0,14.9643,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-S-NA {208V},208,0.506066,548,570.858,42,-1.45019e-05,-4.77696e-05,-0.0299167,-0.0288125,0.2,50.0,13.5919,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-S-NA {240V},240,0.802159,549,572.536,42,-2.05832e-05,2.2712e-05,0.00833646,0.00567008,0.2,50.0,13.6318,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-SW {208V},208,0.86003,608.36,630.459,42,-2.32767e-06,0.000316398,-0.0699173,0.213159,0.2,50.0,15.0109,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-SW {240V},240,2.9217,604.12,628.5,42,-3.59975e-05,0.000363837,-0.0744662,-0.0802006,0.7,50.0,14.9643,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-SW-NA {208V},208,0.505773,548,570.862,42,-1.45336e-05,-4.37318e-05,-0.0285761,-0.0276342,0.2,50.0,13.5919,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M600-SW-NA {240V},240,0.802159,549,572.536,42,-2.05832e-05,2.2712e-05,0.00833646,0.00567008,0.2,50.0,13.6318,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-S {208V},208,2.08856,800.39,835.094,42,-1.28867e-05,-0.000412744,-0.00431894,-0.107438,0.23,50.0,19.8832,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-S {240V},240,6.4626,800.124,846.227,42,-8.30286e-05,-0.00130583,0.00586385,-0.0232823,0.23,50.0,20.1483,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-S-NA {208V},208,0.975306,721,751.212,42,-1.30219e-05,0.000274569,0.0986505,0.075813,0.3,50.0,17.886,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-S-NA {240V},240,1.3483,723,753.434,42,-1.50312e-05,0.00017655,-0.00665003,0.00460258,0.4,50.0,17.9389,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-SW {208V},208,2.08856,800.39,835.094,42,-1.28867e-05,-0.000412744,-0.00431894,-0.107438,0.23,50.0,19.8832,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-SW {240V},240,6.4626,800.124,846.227,42,-8.30286e-05,-0.00130583,0.00586385,-0.0232823,0.23,50.0,20.1483,35.0,50.0,NaN,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-SW-NA {208V},208,0.975306,721,751.212,42,-1.30219e-05,0.000274569,0.0986505,0.075813,0.3,50.0,17.886,35.0,50.0,2024-11-01 00:00:00,N +Zhejiang Hyxi Technology Co Ltd: HYX-M800-SW-NA {240V},240,1.3483,723,753.434,42,-1.50312e-05,0.00017655,-0.00665003,0.00460258,0.4,50.0,17.9389,35.0,50.0,2024-11-01 00:00:00,N +Zhuhai Ruixu Electronic Technology Co Ltd: RX-12K {208V},208,87.267,9880.67,10201.1,380,-1.85106e-06,-4.01401e-05,0.000399696,-0.000768989,24.1,510.0,26.8451,190.0,510.0,NaN,Y +Zhuhai Ruixu Electronic Technology Co Ltd: RX-12K {240V},240,83.0165,11298.1,11652.6,380,-1.26413e-06,-3.50597e-05,0.000462876,-0.000127916,24.0,510.0,30.6648,190.0,510.0,NaN,Y +dcbel Inc: Dcbel Ara (DBHS-ARxx-xx) {240V},240,114.595,7624,8292.2,460,-5.6059e-06,-2.621e-05,-0.00176161,-0.00262258,32.5,470.0,18.0265,450.0,470.0,NaN,Y diff --git a/src/akkudoktoreos/data/cec_modules.csv b/src/akkudoktoreos/data/cec_modules.csv new file mode 100644 index 00000000..d9276347 --- /dev/null +++ b/src/akkudoktoreos/data/cec_modules.csv @@ -0,0 +1,21680 @@ +Name,Manufacturer,Technology,Bifacial,STC,PTC,A_c,Length,Width,N_s,I_sc_ref,V_oc_ref,I_mp_ref,V_mp_ref,alpha_sc,beta_oc,T_NOCT,a_ref,I_L_ref,I_o_ref,R_s,R_sh_ref,Adjust,gamma_pmp,BIPV,Version,Date,solve_return_code,solve_pass +Units,,,,,,m2,m,m,,A,V,A,V,A/K,V/K,C,V,A,A,Ohm,Ohm,%,%/K,,,,, +[0],lib_manufacturer,cec_material,lib_is_bifacial,,,cec_area,lib_length,lib_width,cec_n_s,cec_i_sc_ref,cec_v_oc_ref,cec_i_mp_ref,cec_v_mp_ref,cec_alpha_sc,cec_beta_oc,cec_t_noct,cec_a_ref,cec_i_l_ref,cec_i_o_ref,cec_r_s,cec_r_sh_ref,cec_adjust,cec_gamma_pmp,,,,, +Ablytek 6MN6A270,Ablytek,Mono-c-Si,0,270.0,242.1,1.6268799999999999,1.64,0.992,60.0,9.34,38.63,8.81,30.72,0.00486614,-0.12118231,47.4,1.5826946608006376,9.342590628411061,2.3387860831589717e-10,0.37508385762151936,1352.291897440361,12.009963538187574,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +Ablytek 6MN6A275,Ablytek,Mono-c-Si,0,275.0,246.7,1.6268799999999999,1.64,0.992,60.0,9.42,38.97,8.88,30.99,0.00490782,-0.12224888999999999,47.4,1.5971044250460518,9.423296596413348,2.3744442830587485e-10,0.37524735245322866,1072.2671775099707,12.071980655676196,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +Ablytek 6MN6A280,Ablytek,Mono-c-Si,0,280.0,251.3,1.6268799999999999,1.64,0.992,60.0,9.51,39.31,8.96,31.26,0.00495471,-0.12331547,47.4,1.6114634246546904,9.513934517408861,2.4110533154017177e-10,0.3750103830643723,906.4264194954297,12.126404234784212,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +Ablytek 6MN6A285,Ablytek,Mono-c-Si,0,285.0,256.0,1.6268799999999999,1.64,0.992,60.0,9.59,39.65,9.04,31.53,0.00499639,-0.12438205,47.4,1.6249739394825296,9.593386177842543,2.41726230671783e-10,0.37512678965221785,1062.3978306132437,12.071951475467273,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +Ablytek 6MN6A290,Ablytek,Mono-c-Si,0,290.0,260.6,1.6268799999999999,1.64,0.992,60.0,9.67,39.99,9.12,31.8,0.00503807,-0.12544863,47.4,1.6384850474727,9.672837809525854,2.4235710154783084e-10,0.37524088102288705,1278.6558838435762,12.018507462977505,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P210,Advance Power,Multi-c-Si,0,210.0,186.8,1.63777,1.646,0.995,60.0,7.6,35.94,7.09,29.64,0.00437608,-0.12011147999999999,47.6,1.5231167845498454,7.608307798238048,4.211611909373592e-10,0.24972809857455153,228.45207996844948,12.04459513842403,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P215,Advance Power,Multi-c-Si,0,215.0,191.3,1.63777,1.646,0.995,60.0,7.83,36.0,7.18,29.94,0.004508514000000001,-0.12031199999999999,47.6,1.548184735613635,7.8442734118097315,5.985998395660135e-10,0.1979925726277454,108.61327173234045,15.07142587628882,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P220,Advance Power,Multi-c-Si,0,220.0,195.9,1.63777,1.646,0.995,60.0,7.95,36.06,7.3,30.12,0.00457761,-0.12051252000000001,47.6,1.5535146275884748,7.962534038994422,6.340615598187755e-10,0.1746570058555927,110.78019612240138,15.464042422498862,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M225,Advance Power,Mono-c-Si,0,225.0,200.7,1.63777,1.646,0.995,60.0,8.11,37.02,7.5,30.0,0.0043575029999999996,-0.13193928000000002,46.0,1.6064708262573768,8.125580573918706,7.752035441230185e-10,0.31033087220511824,161.5334493597395,9.817518147440603,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P225,Advance Power,Multi-c-Si,0,225.0,200.5,1.63777,1.646,0.995,60.0,8.1,36.42,7.41,30.36,0.00466398,-0.12171564,47.6,1.5705865526772105,8.114832858613694,6.582864769502749e-10,0.1817046767341998,99.22618567959616,15.653262398844134,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M230,Advance Power,Mono-c-Si,0,230.0,205.3,1.63777,1.646,0.995,60.0,8.18,37.32,7.55,30.48,0.0043951139999999994,-0.13300848,46.0,1.628941177715168,8.195338480386184,8.908457047990221e-10,0.27257997350592633,145.36671864859488,10.995986522005781,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P230,Advance Power,Multi-c-Si,0,230.0,205.0,1.63777,1.646,0.995,60.0,8.17,36.6,7.55,30.48,0.004704285999999999,-0.12231720000000001,47.6,1.5682341678517608,8.181367550029515,5.787991493699657e-10,0.1885265468115325,135.4963923131,14.33521453887876,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M235,Advance Power,Mono-c-Si,0,235.0,209.8,1.63777,1.646,0.995,60.0,8.26,37.5,7.59,30.96,0.004438098,-0.13365,46.0,1.6518281145974623,8.274968950891395,1.1007855408513284e-09,0.21823982924031232,120.42669288135023,12.85152629695135,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P235,Advance Power,Multi-c-Si,0,235.0,209.6,1.63777,1.646,0.995,60.0,8.23,36.72,7.68,30.6,0.004738834000000001,-0.12271823999999999,47.6,1.5653306438583012,8.237333462845234,5.2318689429002e-10,0.18711965185038087,209.9955984255107,13.299640874766727,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M240,Advance Power,Mono-c-Si,0,240.0,214.4,1.63777,1.646,0.995,60.0,8.29,37.56,7.69,31.2,0.004454216999999999,-0.13386384,46.0,1.6514503466569905,8.299288159821664,1.0712755854217394e-09,0.19075980911430457,170.25967906839156,12.537686382193812,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P240,Advance Power,Multi-c-Si,0,240.0,214.2,1.63777,1.646,0.995,60.0,8.42,36.72,7.9,30.54,0.004848236,-0.12271823999999999,47.6,1.5588671229767872,8.425379074850317,4.889091799527406e-10,0.19308016638693526,302.23324971669865,12.45033595458315,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M245,Advance Power,Mono-c-Si,0,245.0,219.0,1.63777,1.646,0.995,60.0,8.32,37.62,7.78,31.5,0.004470336000000001,-0.13407767999999998,46.0,1.6542933276760416,8.324975228137525,1.0876838856962143e-09,0.1544800010921462,258.3346740403551,12.616708047720795,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P245,Advance Power,Multi-c-Si,0,245.0,218.8,1.63777,1.646,0.995,60.0,8.46,36.9,8.0,30.84,0.004871268000000001,-0.1233198,47.6,1.5641716047040335,8.461762473684589,4.784456628565026e-10,0.1727123710701691,829.0321068920052,12.181847870940938,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M250,Advance Power,Mono-c-Si,0,250.0,223.6,1.63777,1.646,0.995,60.0,8.59,37.62,8.17,30.6,0.004615407,-0.13407767999999998,46.0,1.6201004133248855,8.590002241890112,7.068601349769509e-10,0.2607423667196891,999999.9693452594,8.413633182017579,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Advance Power API-P250,Advance Power,Multi-c-Si,0,250.0,223.4,1.63777,1.646,0.995,60.0,8.52,37.2,8.03,31.2,0.0049058159999999995,-0.12432240000000001,47.6,1.582925774718326,8.522951841668212,5.249310241952695e-10,0.1561579110341018,450.7239393206054,12.976643221833426,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M255,Advance Power,Mono-c-Si,0,255.0,228.2,1.63777,1.646,0.995,60.0,8.67,37.68,8.35,30.6,0.004658391,-0.13429152,46.0,1.631867977415856,8.670158021618743,8.127403933879103e-10,0.20148957826873826,11055.017946347238,9.56534954282136,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Advance Power API-P255,Advance Power,Multi-c-Si,0,255.0,228.0,1.63777,1.646,0.995,60.0,8.56,37.5,8.08,31.56,0.004928848,-0.125325,47.6,1.5974875003942204,8.562252513018377,5.423086270281036e-10,0.1413463083596437,537.1443889440758,13.227132442702784,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M260,Advance Power,Mono-c-Si,0,260.0,232.9,1.63777,1.646,0.995,60.0,8.8,37.8,8.5,30.6,0.004728240000000001,-0.1347192,46.0,1.6368655274646726,8.800155384559122,8.226112405695474e-10,0.19469506484806648,11026.406427192414,9.540385260498434,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Advance Power API-P260,Advance Power,Multi-c-Si,0,260.0,231.5,1.951195,1.961,0.995,72.0,7.83,43.2,7.24,35.93,0.004508514000000001,-0.1443744,47.6,1.8490177319711012,7.840986830584401,5.412478209789915e-10,0.23992596690187193,170.98839100966282,14.105081304694274,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M265,Advance Power,Mono-c-Si,0,265.0,235.7,1.951195,1.961,0.995,72.0,8.11,44.42,7.36,36.0,0.004324252,-0.14409848000000003,47.9,1.8791908080381348,8.140946852043207,4.177729832386635e-10,0.38799957843979793,101.68002745277616,14.922097543877584,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P265,Advance Power,Multi-c-Si,0,265.0,236.0,1.951195,1.961,0.995,72.0,7.95,43.27,7.33,36.14,0.00457761,-0.14460834,47.6,1.8596301454293285,7.961118143040083,6.023879539458367e-10,0.21138421659960557,151.1497603178517,14.969883894125921,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M270,Advance Power,Mono-c-Si,0,270.0,240.3,1.951195,1.961,0.995,72.0,8.14,44.64,7.44,36.21,0.0043402480000000005,-0.14481216000000002,47.9,1.8819031774159458,8.165745526630062,3.892769272110789e-10,0.3845052437360585,121.56957998971899,14.208487849922351,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M275,Advance Power,Mono-c-Si,0,275.0,244.9,1.951195,1.961,0.995,72.0,8.18,44.78,7.52,36.58,0.004361576,-0.14526632000000003,47.9,1.8895113350852686,8.19977439541357,4.021321104197974e-10,0.34430323877061547,142.42663934449376,14.445573833560278,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P275,Advance Power,Multi-c-Si,0,275.0,245.2,1.951195,1.961,0.995,72.0,8.17,43.92,7.52,36.58,0.004704285999999999,-0.14678064000000002,47.6,1.8863055831257367,8.182916893782483,6.084426967964598e-10,0.22434235262631744,141.89767242943375,14.81398883600667,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M280,Advance Power,Mono-c-Si,0,280.0,249.5,1.951195,1.961,0.995,72.0,8.21,44.86,7.6,36.86,0.004377572000000001,-0.14552584000000002,47.9,1.8920569355312336,8.224202392545555,4.025025476945049e-10,0.31155023249472774,180.0983590348192,14.396795081789696,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P280,Advance Power,Multi-c-Si,0,280.0,249.8,1.951195,1.961,0.995,72.0,8.23,44.06,7.63,36.72,0.004738834000000001,-0.14724852000000002,47.6,1.8852444698748594,8.239970196821574,5.664777449550359e-10,0.22205429846587657,183.29698795053153,14.056554145431086,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M285,Advance Power,Mono-c-Si,0,285.0,254.0,1.951195,1.961,0.995,72.0,8.39,44.21,7.77,36.72,0.004473548,-0.14341724,47.9,1.875898750884232,8.40174673811269,4.739086637859454e-10,0.24077437019166711,171.97089985775222,15.71737004551376,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P285,Advance Power,Multi-c-Si,0,285.0,256.9,1.951195,1.961,0.995,72.0,8.32,44.21,7.75,36.79,0.004992832000000001,-0.14522985,46.2,1.8684486457386293,8.328752046457947,4.306576621668952e-10,0.23468153172752876,223.0964529050987,13.359806922338521,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M290,Advance Power,Mono-c-Si,0,290.0,258.6,1.951195,1.961,0.995,72.0,8.48,44.43,7.9,36.72,0.004521536,-0.14413092000000002,47.9,1.8736608402053134,8.489978572660018,4.172732727241059e-10,0.26818035176963123,227.90530060846658,14.408766490330018,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P290,Advance Power,Multi-c-Si,0,290.0,261.5,1.951195,1.961,0.995,72.0,8.46,44.28,7.96,36.79,0.005076846,-0.14545980000000003,46.2,1.85944282607089,8.464442239985166,3.806614873241127e-10,0.2423388701439107,461.52103482006305,12.043239848123871,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P295,Advance Power,Multi-c-Si,0,295.0,266.1,1.951195,1.961,0.995,72.0,8.49,44.42,8.0,37.01,0.005094849,-0.1459197,46.2,1.8668082423708057,8.493616028324812,3.8989141749737933e-10,0.2273968015188424,533.9004685536831,12.22374178035016,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P300,Advance Power,Multi-c-Si,0,300.0,270.7,1.951195,1.961,0.995,72.0,8.54,44.86,8.05,37.66,0.005124854,-0.1473651,46.2,1.893026290462884,8.543068638886961,4.3203366519616086e-10,0.1871541859898734,520.8488508709738,13.107041581006257,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P305,Advance Power,Multi-c-Si,0,305.0,275.4,1.951195,1.961,0.995,72.0,8.56,45.0,8.08,37.87,0.005136856,-0.147825,46.2,1.9001308486761508,8.562450132080375,4.401700472371073e-10,0.17432166630681611,609.0258543100819,13.251881910479705,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P310,Advance Power,Multi-c-Si,0,310.0,277.3,1.951195,1.961,0.995,72.0,8.62,45.22,8.16,38.02,0.004963396,-0.15112524,47.6,1.922255382413365,8.621314312506998,5.212563713276657e-10,0.17551296067560437,1151.1131722075531,12.78924786924764,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P315,Advance Power,Multi-c-Si,0,315.0,281.9,1.951195,1.961,0.995,72.0,8.67,45.58,8.24,38.45,0.004992186,-0.15232836,47.6,1.9369989783006765,8.670009300656798,5.230145277300056e-10,0.15903732292001896,148261.98009419083,12.752331251016333,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P320,Advance Power,Multi-c-Si,0,320.0,288.7,1.94,,,72.0,9.38,45.51,8.75,36.59,0.004690000000000001,-0.145632,47.69,1.8277110862434502,9.395964606506988,1.412471412035408e-10,0.4005887081140009,235.3657953842325,5.457233575336352,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P325,Advance Power,Multi-c-Si,0,325.0,293.4,1.94,,,72.0,9.44,45.79,8.81,36.88,0.00472,-0.146528,47.69,1.8403489993664293,9.455412523580435,1.4490430009508047e-10,0.39183891957415146,239.99701319263525,5.619422420359781,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M330,Advance Power,Mono-c-Si,0,330.0,302.4,1.94,,,72.0,9.57,46.76,8.75,37.71,0.0038280000000000002,-0.14028,44.58,1.8782044929573198,9.606055909181267,1.4110440291672723e-10,0.39294308359316454,104.29539816458711,12.552372728373932,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P330,Advance Power,Multi-c-Si,0,330.0,298.0,1.94,,,72.0,9.5,46.08,8.87,37.22,0.004750000000000001,-0.147456,47.69,1.8545637334496166,9.514742576056802,1.50950624956238e-10,0.3777410053186933,243.41334609290845,5.913281977164679,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M335,Advance Power,Mono-c-Si,0,335.0,307.1,1.94,,,72.0,9.61,47.04,8.82,37.98,0.0038439999999999998,-0.14112,44.58,1.8868722859099445,9.642130538438485,1.375601974225539e-10,0.3879317144076514,116.02743233655329,12.270439460413943,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-P335,Advance Power,Multi-c-Si,0,335.0,302.7,1.94,,,72.0,9.56,46.37,8.94,37.55,0.00478,-0.14838400000000002,47.69,1.8674042078030457,9.573102996105542,1.545275739573512e-10,0.3652093514705903,266.4582663237074,6.054766076694603,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M340,Advance Power,Mono-c-Si,0,340.0,311.8,1.94,,,72.0,9.64,47.18,8.96,38.32,0.0038560000000000005,-0.14154,44.58,1.8862342479091858,9.65897249593961,1.2888739033426714e-10,0.3586593911534742,182.23625738273012,11.608569810026566,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M345,Advance Power,Mono-c-Si,0,345.0,315.8,1.94,,,72.0,9.72,47.28,8.98,38.4,0.0038880000000000004,-0.14184,44.6,1.9163111001523923,9.743741252569448,1.814428788835286e-10,0.35147468608065724,143.89864584178102,14.666712116471313,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M350,Advance Power,Mono-c-Si,0,350.0,320.5,1.94,,,72.0,9.81,47.37,9.1,38.48,0.003924,-0.14211,44.6,1.916039192933934,9.83034389103705,1.749519876467694e-10,0.34834172972999017,167.97339838274996,14.229995839445955,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M355,Advance Power,Mono-c-Si,0,355.0,325.5,1.94,,,72.0,9.9,47.47,9.21,38.55,0.004158,-0.1338654,46.67,1.826791635158865,9.921142218228995,5.0004175106332835e-11,0.3683274706327113,172.47206393489014,9.805509084262125,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M360,Advance Power,Mono-c-Si,0,360.0,330.2,1.94,,,72.0,9.99,47.56,9.32,38.63,0.0041958,-0.1341192,46.67,1.827852798768204,10.008590247119857,4.8927131720766306e-11,0.3648973852642902,196.08802998813167,9.521476939925584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M365,Advance Power,Mono-c-Si,0,365.0,334.9,1.94,,,72.0,10.08,47.66,9.43,38.71,0.0042336000000000006,-0.13440119999999997,46.67,1.829155848427646,10.096081386932982,4.777224101575754e-11,0.3625990860537815,227.281320440718,9.220331012688732,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Advance Power API-M370,Advance Power,Mono-c-Si,0,370.0,339.6,1.94,,,72.0,10.17,47.75,9.54,38.78,0.0042714,-0.134655,46.67,1.8300894808297294,10.183575419865418,4.6649467159290595e-11,0.3604817362755912,270.05421379650426,8.921736963700894,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Advanced Solar Power (Hangzhou) ASP-S1-80,Advanced Solar Power (Hangzhou),Thin Film,0,80.0,75.2,0.72,1.2,0.6,145.0,0.95,118.9,0.85,94.1,0.00085215,-0.36359620000000004,45.2,4.258498282267062,0.9583230062492102,6.609643168027976e-13,13.828683656431565,1578.4260040293264,-14.36847465920042,-0.2634,N,2025.7.3,6/23/2025,4.0,first_pass +AE Solar GmbH AE420CMD-108BDE,AE Solar GmbH,Mono-c-Si,0,420.0,398.3,1.95,,,54.0,13.58,39.7,13.28,31.6,0.004753,-0.09528,43.8,1.3368842435041464,13.580004074838463,1.7223709340309733e-12,0.25889825329855787,862821.2565735326,-4.402189169946739,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +AE Solar GmbH AE425CMD-108BDE,AE Solar GmbH,Mono-c-Si,0,425.0,403.1,1.95,,,54.0,13.68,39.8,13.38,31.8,0.004788000000000001,-0.09552,43.8,1.3422862797895116,13.680004007375741,1.814935868222668e-12,0.25098990622795325,856810.1746372904,-4.043126014314502,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +AE Solar GmbH AE430CMD-108BDE,AE Solar GmbH,Mono-c-Si,0,430.0,408.0,1.95,,,54.0,13.78,40.0,13.48,31.9,0.004823000000000001,-0.096,43.8,1.3481640943609523,13.780004015583689,1.7936588377179825e-12,0.2511898691194234,861995.4429561679,-4.19543085100026,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +AE Solar GmbH AE435CMD-108BDE,AE Solar GmbH,Mono-c-Si,0,435.0,412.9,1.95,,,54.0,13.88,40.1,13.58,32.0,0.004858,-0.09624,43.8,1.3519117219065209,13.880004107226712,1.821694163389201e-12,0.25290039167895106,854658.6034825091,-4.129357024483465,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +AE Solar GmbH AE440CMD-108BDE,AE Solar GmbH,Mono-c-Si,0,440.0,417.7,1.95,,,54.0,13.98,40.2,13.68,32.2,0.004893000000000001,-0.09648,43.8,1.3573908365848297,13.98000382219366,1.9213048718982297e-12,0.23558435605959388,861674.3476584363,-3.761073283936499,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +AE Solar GmbH AE570CMD-144BDS,AE Solar GmbH,Mono-c-Si,0,570.0,542.9,2.58,,,72.0,13.91,51.2,13.4,42.5,0.0045903,-0.124416,43.2,1.7143303488161368,13.910003420943005,1.4884514911446636e-12,0.22629528725630238,920147.971275759,-6.887574542765899,-0.282,N,2025.7.3,6/23/2025,2.0,first_pass +AE Solar GmbH AE575CMD-144BDS,AE Solar GmbH,Mono-c-Si,0,575.0,547.7,2.58,,,72.0,13.98,51.3,13.47,42.7,0.0046134,-0.124659,43.2,1.745567810689548,13.98000618095752,2.4107171859314766e-12,0.2290465387866942,518055.19984990335,-3.1170231744133186,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +AE Solar GmbH AE580CMD-144BDS,AE Solar GmbH,Mono-c-Si,0,580.0,552.6,2.58,,,72.0,14.05,51.5,13.54,42.8,0.004636500000000001,-0.125145,43.2,1.7526603083625376,14.050006352319242,2.43448239597527e-12,0.23409116262787377,517761.7311495633,-3.0783467967440714,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +AE Solar GmbH AE585CMD-144BDS,AE Solar GmbH,Mono-c-Si,0,585.0,557.5,2.58,,,72.0,14.13,51.6,13.61,43.0,0.0046629,-0.125388,43.2,1.7302460406005131,14.130124132698729,1.5790781686628576e-12,0.22819225054049697,25975.081035313957,-6.549044723951956,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +AE Solar GmbH AE590CMD-144BDS,AE Solar GmbH,Mono-c-Si,0,590.0,562.3,2.58,,,72.0,14.19,51.8,13.68,43.1,0.004682700000000001,-0.125874,43.2,1.736423409542374,14.190083781192358,1.5715122432544212e-12,0.23342598161588857,39535.308988999925,-6.6196942360049125,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +AE Solar GmbH AE595CMD-144BDS,AE Solar GmbH,Mono-c-Si,0,595.0,567.2,2.58,,,72.0,14.26,51.9,13.75,43.3,0.0047058000000000004,-0.126117,43.2,1.7418478575226488,14.260003150109283,1.6364552986616821e-12,0.20349777358425886,921201.0138406261,-6.342458477160937,-0.282,N,2025.7.3,6/23/2025,2.0,first_pass +AEG SOLAR ENERGY SRL ALPS54D30-425/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,425.0,400.5,1.99,,,54.0,13.94,38.9,13.14,32.35,0.005994199999999999,-0.098417,45.5,1.3570964693840326,13.956157225535438,4.873964440084385e-12,0.172584193460916,148.9007911820473,-1.4547319092692466,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS54D30-435/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,435.0,410.1,1.99,,,54.0,14.08,39.3,13.28,32.75,0.0060544,-0.09942899999999999,45.5,1.3720352148924353,14.0952844966891,5.027767251590074e-12,0.1668586579338062,153.70934073680368,-1.285509659305056,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS54D30-440/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,440.0,414.9,1.99,,,54.0,14.15,39.5,13.35,32.95,0.0060845000000000005,-0.09993500000000001,45.5,1.379503258899138,14.16486138476006,5.105278604091552e-12,0.16404186376481272,156.18950827470812,-1.2024052014695932,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS54D30-445/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,445.0,419.8,1.99,,,54.0,14.21,39.7,13.42,33.15,0.0061103,-0.100441,45.5,1.3865205954989923,14.223735052656426,5.135887192614056e-12,0.1613971504376395,166.978137702417,-1.1921318182879528,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS54D30-450/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,450.0,424.6,1.99,,,54.0,14.28,39.9,13.53,33.25,0.0061404,-0.10094700000000001,45.5,1.390083689940664,14.290762424275124,4.8291006172173424e-12,0.16718321496758146,221.82514401749287,-1.7461206421100288,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS54D30-455/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,455.0,429.5,1.99,,,54.0,14.34,40.1,13.6,33.45,0.006166199999999999,-0.101453,45.5,1.3971045605074195,14.349698777520244,4.85971458824008e-12,0.16455608396636728,243.30223519093093,-1.7327251768077327,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-570/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,570.0,537.5,2.58,,,72.0,13.81,52.1,13.09,43.55,0.0059383,-0.131813,45.5,1.8174606163966838,13.819683085223474,4.846823570106012e-12,0.21414647760450262,305.41534963146484,-1.4460232132520852,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-575/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,575.0,542.4,2.58,,,72.0,13.87,52.3,13.14,43.75,0.005964099999999999,-0.13231900000000002,45.5,1.8255326320216647,13.880138128157004,4.948965855258719e-12,0.21116508373651424,288.8955112188125,-1.3094334813851125,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-580/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,580.0,547.2,2.58,,,72.0,13.93,52.5,13.2,43.95,0.0059899,-0.132825,45.5,1.8329681207118385,13.939868292133434,5.006867492962921e-12,0.20825320349557153,293.96850943643375,-1.250787837688209,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-585/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,585.0,552.0,2.58,,,72.0,13.99,52.7,13.25,44.15,0.0060157,-0.133331,45.5,1.8410412852749756,14.000302006842304,5.111038677931512e-12,0.20531875182619833,278.8203684443402,-1.1158303429923435,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-590/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,590.0,556.9,2.58,,,72.0,14.05,52.9,13.3,44.35,0.0060415,-0.133837,45.5,1.8491159462308302,14.06072002744794,5.216657769901521e-12,0.20240600645464277,265.2795813692353,-0.981709410749806,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-595/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,595.0,561.7,2.58,,,72.0,14.11,53.1,13.36,44.55,0.006067299999999999,-0.13434300000000002,45.5,1.8565502713879818,14.120444677187166,5.275979808446285e-12,0.1995693214290255,269.6036514480021,-0.9250985778371645,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D60-600/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,600.0,570.0,2.53,,,66.0,15.73,48.1,14.91,40.25,0.0072358,-0.113035,44.49,1.6501280542412466,15.741889744327269,3.403415095691291e-12,0.17462533600374855,231.02738486742638,1.9566426725098158,-0.285,N,2025.7.3,6/23/2025,2.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-600/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,600.0,566.6,2.58,,,72.0,14.17,53.3,13.41,44.75,0.006093099999999999,-0.134849,45.5,1.864626014362525,14.180842167771024,5.383636219654641e-12,0.19670186034765744,257.0763906075479,-0.7925648835094908,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D60-605/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,605.0,574.9,2.53,,,66.0,15.76,48.3,14.94,40.5,0.007249599999999999,-0.113505,44.49,1.6584923423735485,15.771515471602447,3.5009740081526696e-12,0.1687421738892145,230.93944865946,2.1798591465540498,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS72D30-605/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,605.0,571.4,2.58,,,72.0,14.23,53.5,13.46,44.95,0.0061189,-0.135355,45.5,1.8727032381393744,14.241224484011536,5.4927568809638595e-12,0.19385535022235229,245.76254658766152,-0.6608410401716032,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D60-610/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,610.0,579.7,2.53,,,66.0,15.8,48.9,14.99,40.7,0.007268,-0.11491499999999999,44.49,1.6726960490856786,15.81153181632643,3.1448918689437247e-12,0.19340235312586534,264.9848989217945,1.2474212263988798,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D60-615/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,615.0,584.6,2.53,,,66.0,15.86,49.2,15.04,40.9,0.007295599999999999,-0.11562,44.49,1.6823465984346495,15.872267684345438,3.1221468803043787e-12,0.19759845880439045,255.46072435363854,1.156250924120573,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D60-620/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,620.0,589.5,2.53,,,66.0,15.92,49.4,15.09,41.1,0.0073232,-0.11609,44.49,1.6901731337010077,15.932786308348366,3.1860428082344566e-12,0.19510657617708008,242.9236500742058,1.2970831528512887,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-620/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,620.0,584.8,2.79,,,78.0,13.76,56.7,13.16,47.1,0.0059168,-0.14345100000000002,45.5,1.964097236353083,13.760655840812865,3.990251097739821e-12,0.25990054818988856,5452.896121476264,-3.02410902176649,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D60-625/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,625.0,594.3,2.53,,,66.0,15.98,49.6,15.13,41.3,0.007350799999999999,-0.11656000000000001,44.49,1.698497946827022,15.994089494846714,3.2761557642754426e-12,0.19261683450286948,218.46184248418615,1.5054084951872369,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-625/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,625.0,589.6,2.79,,,78.0,13.83,56.85,13.21,47.3,0.0059469,-0.1438305,45.5,1.9719082828347594,13.832124701747896,4.1602378585148236e-12,0.2527468862525807,1645.1671199750303,-2.7245038052115627,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-630/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,630.0,594.4,2.79,,,78.0,13.88,57.0,13.26,47.5,0.0059684,-0.14421,45.5,1.978449661489409,13.882029910873069,4.257727096900944e-12,0.2460527817854024,1682.4446400096597,-2.5677477279124155,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-635/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,635.0,599.3,2.79,,,78.0,13.94,57.15,13.31,47.7,0.005994199999999999,-0.1445895,45.5,1.985628163391761,13.942657463222007,4.3968058025370786e-12,0.23920749407085332,1254.7878323746274,-2.341091360399361,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-640/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,640.0,604.1,2.79,,,78.0,14.0,57.3,13.36,47.9,0.00602,-0.144969,45.5,1.9928081514388956,14.003246022456947,4.539535776318752e-12,0.23241380918531174,1002.3939715798911,-2.1154453330939056,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-645/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,645.0,609.0,2.79,,,78.0,14.06,57.45,13.41,48.1,0.0060458,-0.1453485,45.5,1.9999896069666416,14.06379608144537,4.685986632117754e-12,0.22567114115639803,835.8451487840989,-1.8908038744743254,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-650/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,650.0,613.8,2.79,,,78.0,14.12,57.6,13.46,48.3,0.006071599999999999,-0.14572800000000002,45.5,2.007172513728964,14.124308117111346,4.836228633263648e-12,0.2189789229101072,717.710852760813,-1.6671737348669902,-0.299,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS78D30-655/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,655.0,618.6,2.79,,,78.0,14.18,57.75,13.51,48.5,0.0060974,-0.1461075,45.5,2.014356806582271,14.184782603583828,4.9903302749644025e-12,0.21233656277670226,629.559280402125,-1.4445166703018668,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS78D30-660/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,660.0,623.5,2.79,,,78.0,14.24,57.9,13.55,48.7,0.0061232,-0.14648699999999998,45.5,2.0222244918308654,14.24586555362176,5.19387021382415e-12,0.20568166455535197,499.3401895655707,-1.1480996813479365,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +AEG SOLAR ENERGY SRL ALPS66D50-690/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,690.0,653.8,2.99,,,66.0,18.28,47.9,17.25,40.0,0.008226,-0.11352299999999999,44.59,1.6617367632540734,18.299218673967037,5.443546459899043e-12,0.1527148092576807,145.25594747640912,3.8281458895349614,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS66D50-695/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,695.0,658.6,2.99,,,66.0,18.31,48.2,17.27,40.25,0.008239499999999999,-0.114234,44.59,1.6724980969028782,18.329877016864163,5.482755018940325e-12,0.15343732316646963,141.34099748175333,3.877847841665363,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS66D50-700/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,700.0,663.5,2.99,,,66.0,18.34,48.5,17.28,40.5,0.008253,-0.11494499999999999,44.59,1.6837052925356004,18.361285782816097,5.56034121674234e-12,0.15413678158136837,132.80547874656713,3.989177549548672,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS66D50-705/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,705.0,668.3,2.99,,,66.0,18.37,48.8,17.3,40.75,0.0082665,-0.115656,44.59,1.6944774573269488,18.39194446237386,5.6002659554622545e-12,0.15485373878173825,129.6301151571371,4.038687348592886,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS66D50-710/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,710.0,673.2,2.99,,,66.0,18.4,49.1,17.32,41.0,0.00828,-0.11636700000000001,44.59,1.705253502228114,18.422603294588033,5.640407558467811e-12,0.15556803044231204,126.63869649721835,4.0882333091671414,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS66D50-715/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,715.0,678.1,2.99,,,66.0,18.45,49.4,17.33,41.25,0.008302499999999999,-0.11707799999999999,44.59,1.7173354449790383,18.475448792766407,5.801130366818338e-12,0.15604785540860894,113.1323973415649,4.315882766031401,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AEG SOLAR ENERGY SRL ALPS66D50-720/TP,AEG SOLAR ENERGY SRL,Mono-c-Si,0,720.0,682.9,2.99,,,66.0,18.51,49.7,17.35,41.5,0.0083295,-0.117789,44.59,1.7294131830048751,18.538261236867058,5.967166581653081e-12,0.15643769592910708,102.4603774521658,4.540477515666612,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +AIMS Power PV555MONO,AIMS Power,Mono-c-Si,0,555.0,522.2,2.61,,,72.0,13.74,49.9,12.81,43.34,0.0038884199999999996,-0.1250993,43.3,1.8529818786801155,13.746007451943246,2.68122737336185e-11,0.04840034147748436,110.69929471947734,14.689736280195678,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Alexus Solar ALEX-400-B-54-S,Alexus Solar,Mono-c-Si,0,400.0,370.0,1.95,,,54.0,13.67,37.21,12.58,31.18,0.006698300000000001,-0.11535100000000001,46.8,1.4406606572478118,13.697388253148674,7.943450082790215e-11,0.12405401703981983,61.91772855209001,0.9333814217019659,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Alexus Solar ALEX-405-B-54-S,Alexus Solar,Mono-c-Si,0,405.0,374.7,1.95,,,54.0,13.76,37.38,12.92,31.35,0.0067424,-0.11587800000000001,46.8,1.4325449330017292,13.772434415490283,6.2817237140432e-11,0.12362838072808505,136.80792166494652,-1.0860328961673293,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Alexus Solar ALEX-410-B-54-S,Alexus Solar,Mono-c-Si,0,410.0,379.5,1.95,,,54.0,13.85,37.55,13.01,31.52,0.006786500000000001,-0.116405,46.8,1.4394189325662214,13.861998029775501,6.366731951581629e-11,0.12099227565124458,139.66818473422438,-1.0320379810166795,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Alexus Solar ALEX-540-B-72-S,Alexus Solar,Mono-c-Si,0,540.0,499.7,2.58,,,72.0,13.84,49.52,12.96,41.67,0.0067816,-0.153512,46.8,1.9038953832092915,13.853568516842707,6.845032331546582e-11,0.15010533371409987,153.1086901810556,-0.43328605170828494,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Alexus Solar ALEX-545-B-72-S,Alexus Solar,Mono-c-Si,0,545.0,504.5,2.58,,,72.0,13.91,49.68,13.03,41.83,0.006815900000000001,-0.154008,46.8,1.9103306302356606,13.923225480099347,6.908674120574125e-11,0.14763660199589948,155.27792857951243,-0.400534189561794,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Alexus Solar ALEX-550-B-72-S,Alexus Solar,Multi-c-Si,0,550.0,509.3,2.58,,,24.0,13.98,49.84,13.1,41.99,0.006850200000000001,-0.15450400000000003,46.8,1.9167665854592453,13.9928884401526,6.972591251098309e-11,0.1451942144481023,157.49114048374148,-0.367923883769718,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Alexus Solar ALEX-550-W-72-S,Alexus Solar,Multi-c-Si,0,550.0,509.3,2.58,,,24.0,13.98,49.84,13.1,41.99,0.006850200000000001,-0.15450400000000003,46.8,1.9167665854592453,13.9928884401526,6.972591251098309e-11,0.1451942144481023,157.49114048374148,-0.367923883769718,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Allesun Industries Inc Allesun-530-72IIMBG,Allesun Industries Inc,Mono-c-Si,0,530.0,498.1,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0056211,-0.1251204,43.8,1.7744467439656217,13.711662483516148,1.202185807800103e-11,0.2455313577423321,2024.8230159565205,5.79229326188321,-0.3364,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc AS-530-72IIMB,Allesun Industries Inc,Mono-c-Si,0,530.0,498.4,2.56,,,72.0,13.23,49.24,12.54,42.26,0.00456435,-0.12280456000000001,43.3,1.814610670990128,13.234339296260107,2.1455452769656503e-11,0.09777150055490794,298.09360365527203,13.407111887854127,-0.3426,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc Allesun-535-72IIMBG,Allesun Industries Inc,Mono-c-Si,0,535.0,502.9,2.56,,,72.0,13.79,49.34,13.17,40.63,0.0056539,-0.1253236,43.8,1.776552335913982,13.79000334977844,1.1965976245375143e-11,0.2429051659628744,999989.8203420852,5.695631771801544,-0.3364,N,2025.7.3,6/23/2025,2.0,first_pass +Allesun Industries Inc AS-535-72IIMB,Allesun Industries Inc,Mono-c-Si,0,535.0,503.2,2.56,,,72.0,13.31,49.35,12.62,42.39,0.00459195,-0.12307890000000002,43.3,1.8191233662604593,13.314112501802075,2.1740315181882313e-11,0.09424916675862292,305.0348613804326,13.471552586899694,-0.3426,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc Allesun-540-72IIMBG,Allesun Industries Inc,Mono-c-Si,0,540.0,507.7,2.56,,,72.0,13.85,49.42,13.27,40.7,0.0056785,-0.12552680000000002,43.8,1.7818858068042014,13.850003200009928,1.2486416003707891e-11,0.23104261807524534,999997.8409788782,6.025310561840482,-0.3364,N,2025.7.3,6/23/2025,2.0,first_pass +Allesun Industries Inc AS-540-72IIMB,Allesun Industries Inc,Mono-c-Si,0,540.0,508.0,2.56,,,72.0,13.4,49.53,12.7,42.52,0.004623,-0.12352782000000001,43.3,1.8256127311257133,13.404392715742393,2.1830318060185025e-11,0.0960841270240157,293.10510780306606,13.44947321159097,-0.3426,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc Allesun-570-78IIMBG,Allesun Industries Inc,Mono-c-Si,0,570.0,535.5,2.79,,,78.0,13.65,53.3,12.76,44.68,0.005596500000000001,-0.135382,43.8,1.955099354170158,13.668686285373123,1.922728390597268e-11,0.19500065734076194,142.44452174497363,10.047043991924255,-0.3364,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc Allesun-575-78IIMBG,Allesun Industries Inc,Mono-c-Si,0,575.0,540.3,2.79,,,78.0,13.72,53.44,12.83,44.82,0.005625200000000001,-0.13573759999999999,43.8,1.9603918572836863,13.738322208049361,1.9375372068892512e-11,0.19253208856931472,144.17150260463768,10.068476166943883,-0.3364,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc Allesun-580-78IIMBG,Allesun Industries Inc,Mono-c-Si,0,580.0,545.1,2.79,,,78.0,13.79,53.59,12.9,44.97,0.0056539,-0.1361186,43.8,1.9660879441932115,13.80795127160421,1.9533658312749317e-11,0.1899824397300848,145.94274487307692,10.094317392226738,-0.3364,N,2025.7.3,6/23/2025,2.0,first_pass +Allesun Industries Inc Allesun-585-78IIMBG,Allesun Industries Inc,Mono-c-Si,0,585.0,549.9,2.79,,,78.0,13.86,53.73,12.97,45.11,0.0056826,-0.1364742,43.8,1.971383080128556,13.87759745528386,1.968314612410438e-11,0.18756704414598527,147.73040531942945,10.115811051282314,-0.3364,N,2025.7.3,6/23/2025,4.0,first_pass +Allesun Industries Inc Allesun-590-78IIMBG,Allesun Industries Inc,Mono-c-Si,0,590.0,554.7,2.79,,,78.0,13.93,53.87,13.04,45.25,0.005711300000000001,-0.1368298,43.8,1.9766795401907538,13.947248581833342,1.98333216244667e-11,0.1851772962098855,149.54967133166397,10.13733960385943,-0.3364,N,2025.7.3,6/23/2025,2.0,first_pass +Alps Technology ATI-S572-175,Alps Technology,Mono-c-Si,0,175.0,151.3,1.2873999999999999,1.57,0.82,72.0,5.17,43.99,4.78,36.63,0.0021455500000000004,-0.15906784,49.9,1.9749354507049433,5.175793567566411,1.0648790131630804e-09,0.3196218453123019,285.22068981245434,15.34075110425485,-0.5072,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-S572-180,Alps Technology,Mono-c-Si,0,180.0,155.7,1.2873999999999999,1.57,0.82,72.0,5.31,44.06,4.9,36.72,0.0022036499999999997,-0.15932096,49.9,1.9814000532236133,5.316247704354486,1.132591202034061e-09,0.3028920572519131,257.43170572680543,15.677003442087557,-0.5072,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-S572-185,Alps Technology,Mono-c-Si,0,185.0,160.2,1.2873999999999999,1.57,0.82,72.0,5.43,44.14,5.03,36.79,0.00225345,-0.15961024,49.9,1.9805688371422063,5.435492804198094,1.1071050951819178e-09,0.298126593219376,294.71791736362604,15.238219098596485,-0.5072,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-M660-220,Alps Technology,Multi-c-Si,0,220.0,189.1,1.60974,1.626,0.99,60.0,7.95,36.06,7.3,30.12,0.0043566,-0.13068144,50.2,1.665488098707161,7.95926580384981,3.029944061980341e-09,0.14254324839111823,122.30122763924291,20.89323260900283,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-M660-225,Alps Technology,Multi-c-Si,0,225.0,193.6,1.60974,1.626,0.99,60.0,8.04,36.24,7.44,30.24,0.00440592,-0.13133376,50.2,1.6649572009869715,8.047361942260473,2.7573475848458835e-09,0.14925838632998756,163.00561128604508,19.821127186756815,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-M660-230,Alps Technology,Multi-c-Si,0,230.0,198.0,1.60974,1.626,0.99,60.0,8.1,36.42,7.58,30.36,0.0044388000000000006,-0.13198608,50.2,1.661184138452164,8.103930781496167,2.404955481161251e-09,0.15727494286011343,324.0902444221933,18.37060868596949,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-M660-235,Alps Technology,Multi-c-Si,0,235.0,202.5,1.60974,1.626,0.99,60.0,8.23,36.72,7.68,30.6,0.004510040000000001,-0.13307328,50.2,1.6772905611747284,8.23500154396293,2.5137396065493774e-09,0.156759765238611,257.94707128004035,18.65623356531081,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +Alps Technology ATI-M660-240,Alps Technology,Multi-c-Si,0,240.0,207.0,1.60974,1.626,0.99,60.0,8.32,36.84,7.83,30.72,0.004559360000000001,-0.13350816000000001,50.2,1.6751789516758782,8.322024354784398,2.3245360892275007e-09,0.1550595878701791,637.2882350459288,17.76101876618983,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE385MD-108BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,385.0,358.9,1.93,,,54.0,13.52,36.7,12.65,30.4,0.0048671999999999995,-0.09101600000000001,46.9,1.3034611880884928,13.543269864662097,7.799454101189427e-12,0.17475570053595363,101.53462899826133,4.8892104023447445,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,390.0,360.9,1.93,,,54.0,13.6,36.81,12.83,30.4,0.005168,-0.09762012,46.7,1.3650703967035729,13.612014426481453,2.6109433481441903e-11,0.17141156934307517,194.03317501761623,8.037213270621239,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,390.0,363.7,1.93,,,54.0,13.61,36.9,12.73,30.6,0.0048996,-0.091512,46.9,1.3114902706187304,13.63342421783009,8.005015266812499e-12,0.17144929653946606,99.61593578420882,5.057391562259099,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE390MD-108E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,390.0,358.8,1.93,,,54.0,13.5,36.5,12.82,30.4,0.00621,-0.10074000000000001,47.5,1.3867765616626684,13.503849364475771,4.98273588941715e-11,0.14305156819698722,501.69223050716414,9.279348357673491,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,395.0,365.7,1.93,,,54.0,13.71,36.94,12.92,30.57,0.0052098,-0.09796488,46.7,1.3720222073205768,13.722971297602829,2.740637545253245e-11,0.1650143476210528,174.41175088341876,8.39673383080809,-0.3571,N,2025.7.3,6/23/2025,4.0,bootstrapping +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,395.0,368.5,1.93,,,54.0,13.7,37.0,12.81,30.8,0.004931999999999999,-0.09176,46.9,1.3177093673335,13.722667082533869,8.523434129108857e-12,0.1603145498203338,96.89422243007171,5.543457022701174,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,395.0,363.6,1.93,,,54.0,13.55,36.7,12.88,30.6,0.006233000000000001,-0.10129200000000002,47.5,1.3944978545088664,13.553017039581096,5.0179618851351244e-11,0.14038019491280232,630.4698578386519,9.305044123164631,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE400MD-108,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,400.0,370.4,1.93,,,54.0,13.79,37.03,13.03,30.71,0.0052401999999999995,-0.09820356,46.7,1.3750949874877019,13.800074199055606,2.7501035481798503e-11,0.15878127862195013,217.34670915385206,8.364904316448886,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE400MD-108BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,400.0,373.3,1.93,,,54.0,13.79,37.1,12.9,31.0,0.004964399999999999,-0.09200799999999999,46.9,1.3234383211487937,13.811109620122915,8.984831552286657e-12,0.14936644150944406,97.57462334273512,5.941503666365742,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE400MD-108E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,400.0,368.3,1.93,,,54.0,13.6,36.9,12.96,30.8,0.006256,-0.101844,47.5,1.4011624663318891,13.60090288951491,4.9628934067179925e-11,0.13784909219975763,2076.3868804000244,9.16456062060021,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,405.0,375.2,1.93,,,54.0,13.86,37.15,13.13,30.86,0.0052668,-0.09852179999999999,46.7,1.3789845927791873,13.867428896432132,2.7415137575428388e-11,0.15418972274561438,287.6698586381442,8.282130965200185,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,405.0,378.1,1.93,,,54.0,13.87,37.2,12.98,31.2,0.004993199999999999,-0.09225600000000002,46.9,1.3291936179512382,13.889601924388248,9.464933222437142e-12,0.13867250450656887,98.12238855057545,6.341961770395264,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE405MD-108E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,405.0,373.1,1.93,,,54.0,13.65,37.1,13.05,31.0,0.006279000000000001,-0.102396,47.5,1.4100388321025887,13.65000177223004,5.108168095959561e-11,0.12982167027926386,999990.615671546,9.382107012910888,-0.369,N,2025.7.3,6/23/2025,2.0,bootstrapping +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,410.0,380.0,1.93,,,54.0,13.94,37.23,13.22,31.03,0.005297199999999999,-0.09873395999999998,46.7,1.3835731033149834,13.946268868831952,2.8483137380487656e-11,0.1446860603969464,321.7364673293911,8.563276882364033,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,410.0,382.9,1.93,,,54.0,13.95,37.3,13.04,31.5,0.005021999999999999,-0.092504,46.9,1.3380215390775663,13.96811664513415,1.0604741649926612e-11,0.11923288536994202,91.81052788722718,7.290265773887954,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,410.0,377.8,1.93,,,54.0,13.7,37.3,13.12,31.2,0.0063019999999999994,-0.10294800000000001,47.5,1.3967739899247436,13.700003440050715,3.4605764969549564e-11,0.13590256723209554,541247.099500514,5.961774098017622,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE415MD-108,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,415.0,384.8,1.93,,,54.0,14.02,37.38,13.31,31.19,0.005327599999999999,-0.09913176,46.7,1.3892249023638876,14.025280845986826,2.8722234554478926e-11,0.14148410270952197,375.6229891721826,8.582029243737379,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE415MD-108E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,415.0,382.6,1.93,,,54.0,14.02,37.4,13.31,31.2,0.0064491999999999996,-0.10322400000000001,47.5,1.398990581908241,14.02498490456237,3.417638197670784e-11,0.14061534970492895,395.4794359644908,5.6807489189556115,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE435MD-120BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,435.0,402.6,2.14,,,60.0,13.66,41.0,12.91,33.8,0.006147,-0.11234000000000002,46.8,1.5168492145828365,13.660005123609068,2.492255090866171e-11,0.19551008400893924,521259.5812577124,3.974051548610819,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,440.0,408.4,2.14,,,60.0,13.7,41.0,12.96,34.0,0.006849999999999999,-0.10619,46.9,1.5135651374813959,13.709144769084087,2.332398904558034e-11,0.17860580115318908,267.57367833209804,9.397829558386805,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,440.0,407.3,2.14,,,60.0,13.71,41.1,13.01,33.9,0.0061695,-0.11261400000000002,46.8,1.530061225861389,13.715396801257656,2.9420955575584694e-11,0.1919958731491362,487.74512203327254,5.374894928393569,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE440MD-120E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,440.0,407.4,2.14,,,60.0,13.7,41.0,12.96,34.0,0.008219999999999998,-0.10578000000000001,47.3,1.5339741621950171,13.708418707853015,3.346572822188057e-11,0.17513848402000146,285.0077837616331,12.954841960022051,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,445.0,413.2,2.14,,,60.0,13.77,41.1,13.05,34.1,0.006885,-0.10644900000000002,46.9,1.5163286672283096,13.777318343898848,2.3105963048786474e-11,0.1767137753888858,332.4999137543975,9.26134501558788,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,445.0,412.1,2.14,,,60.0,13.79,41.2,13.11,34.0,0.006205499999999999,-0.11288800000000002,46.8,1.532844616725266,13.793421942840396,2.917083776598569e-11,0.1898683483840349,765.1456381279611,5.244836173298755,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,445.0,412.2,2.14,,,60.0,13.77,41.1,13.05,34.1,0.008261999999999999,-0.10603800000000001,47.3,1.5367727625142051,13.776627873643239,3.315903068285431e-11,0.17326459098127908,359.97268373132243,12.815941616259007,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE450MD-120,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,450.0,417.9,2.14,,,60.0,13.83,41.2,13.15,34.2,0.006915000000000001,-0.10670800000000001,46.9,1.4949085393913026,13.834764625323038,1.4764725967381484e-11,0.17893378944383853,519.3806800546901,5.305007793914145,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE450MD-120BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,450.0,416.9,2.14,,,60.0,13.86,41.3,13.2,34.2,0.0062369999999999995,-0.113162,46.8,1.5379526720209409,13.861701923804256,3.0090958026906563e-11,0.17918269785852087,1459.2152717686315,5.460211595319668,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE450MD-120E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,450.0,417.0,2.14,,,60.0,13.83,41.2,13.15,34.2,0.008298,-0.10629600000000002,47.3,1.5385084783106149,13.833401828137433,3.2286408960195016e-11,0.1716155757216321,697.6964730633565,12.517906247989588,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,455.0,422.7,2.14,,,60.0,13.9,41.3,13.27,34.3,0.006950000000000001,-0.10696699999999999,46.9,1.519243552647899,13.900002408752226,2.1722004380579083e-11,0.17328539962545253,999999.9280313763,8.599571546797785,-0.343,N,2025.7.3,6/23/2025,2.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,455.0,421.7,2.14,,,60.0,13.92,41.5,13.27,34.3,0.006264,-0.11371000000000002,46.8,1.5431939496192022,13.920547710697514,2.9121459259203986e-11,0.18500733510052955,4701.944025931887,5.13928438324846,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,455.0,421.7,2.14,,,60.0,13.9,41.3,13.27,34.3,0.00834,-0.106554,47.3,1.5404753685848498,13.900002339972717,3.1595068267666336e-11,0.16833508132177363,999999.7820996549,12.259051387163826,-0.347,N,2025.7.3,6/23/2025,2.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE460MD-120,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,460.0,427.5,2.14,,,60.0,13.99,41.5,13.37,34.4,0.006995,-0.10748500000000001,46.9,1.5262397434240038,13.990150895878923,2.1718878190891063e-11,0.1749220515928578,16217.546260955603,8.542025358648127,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE460MD-120E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,460.0,426.5,2.14,,,60.0,13.99,41.5,13.37,34.4,0.008393999999999999,-0.10707000000000001,47.3,1.5474122325560762,13.990121350351462,3.150848823302781e-11,0.1749905284356913,20173.983255162333,12.175740551228378,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE525MD-144BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,525.0,489.5,2.56,,,72.0,13.65,49.2,12.81,41.0,0.008736,-0.131364,46.3,1.834147533945418,13.665716653732733,2.996510684419827e-11,0.195542232471496,169.8295028652945,8.155706510072113,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE530MD-144,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,530.0,497.3,2.56,,,72.0,13.71,49.3,12.91,41.1,0.0074034,-0.129659,46.5,1.7526390565399375,13.725367886097393,8.180302709604853e-12,0.20819074879783522,185.73115092491344,-1.1309928421117572,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE530MD-144BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,530.0,494.3,2.56,,,72.0,13.71,49.3,12.89,41.1,0.0087744,-0.131631,46.3,1.8366064706413259,13.724043390210115,2.960704205267865e-11,0.19375945763482993,189.15969736701123,8.004199889816382,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE530MD-144E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,530.0,494.9,2.56,,,72.0,13.71,49.3,12.91,41.1,0.0087744,-0.126701,47.1,1.7947120147961704,13.72395103760194,1.583481065448533e-11,0.20087865008366035,197.4079908634115,6.6655923813882305,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,535.0,502.1,2.56,,,72.0,13.79,49.4,12.99,41.2,0.007446599999999999,-0.129922,46.5,1.7562482599857911,13.805026734378538,8.238334314873244e-12,0.20596005561209416,189.0090755216918,-1.1221525604180878,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,535.0,499.0,2.56,,,72.0,13.79,49.4,12.97,41.3,0.0088256,-0.13189800000000002,46.3,1.8426635231047643,13.80321090166574,3.0813749634071764e-11,0.18271354949529686,190.72277832911828,8.303842266063786,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE535MD-144E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,535.0,499.7,2.56,,,72.0,13.79,49.4,12.99,41.2,0.0088256,-0.12695800000000002,47.1,1.7984081812322412,13.803619983140646,1.594690227832716e-11,0.1986764273717134,201.15648625906738,6.675022496028749,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,540.0,506.9,2.56,,,72.0,13.85,49.5,13.07,41.3,0.007479,-0.130185,46.5,1.7586614272033856,13.863282077636065,8.141236681118677e-12,0.20413937816338423,212.8680827841922,-1.2604876888933165,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,540.0,503.8,2.56,,,72.0,13.86,49.5,13.05,41.4,0.0088704,-0.132165,46.3,1.8457879096046925,13.872274711087648,3.073698837182226e-11,0.18082346063909208,204.17695900806896,8.233018663700987,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE540MD-144E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,540.0,504.5,2.56,,,72.0,13.85,49.5,13.07,41.3,0.008864,-0.127215,47.1,1.8008733115901236,13.861935939435174,1.5764335014127415e-11,0.19689225712276964,228.46612094084034,6.529647792564175,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE545MD-144,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,545.0,511.7,2.56,,,72.0,13.93,49.6,13.15,41.5,0.007522200000000001,-0.130448,46.5,1.7643882935868505,13.942544756310017,8.478425907326121e-12,0.19326742960037535,214.60881595483266,-0.978559432171965,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE545MD-144BS,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,1,545.0,508.6,2.56,,,72.0,13.93,49.7,13.12,41.6,0.0089152,-0.132699,46.3,1.8537079528062723,13.941922924903297,3.110862205810369e-11,0.17780524504717252,207.73653336398198,8.293458827670536,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE545MD-144E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,545.0,509.3,2.56,,,72.0,13.93,49.6,13.15,41.5,0.0089152,-0.12747200000000003,47.1,1.8067491471374961,13.941246425772032,1.6406709163736074e-11,0.18602481941540286,230.4132707938853,6.827078460974034,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,550.0,516.5,2.56,,,72.0,14.0,49.8,13.23,41.6,0.007560000000000001,-0.130974,46.5,1.7692054928512368,14.011887917256988,8.226945051745333e-12,0.1989670771232191,234.31683004573625,-1.2681278910711593,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE550MD-144E,ALTERNATIVE ENERGY (AE) SOLAR CO LTD,Mono-c-Si,0,550.0,514.1,2.56,,,72.0,14.0,49.8,13.23,41.6,0.008960000000000001,-0.12798600000000002,47.1,1.811669959430817,14.010593292396818,1.593088401563235e-11,0.19176079989713365,253.4293513457966,6.521997069167432,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-245W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,245.0,216.4,1.6236,1.64,0.99,60.0,8.75,37.5,8.17,30.0,0.006125000000000001,-0.13874999999999998,46.8,1.6767863339420725,8.758048807704904,1.6771334070687288e-09,0.33173373897368075,360.63391433261313,11.67660976986628,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-250W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,250.0,221.0,1.6236,1.64,0.99,60.0,8.83,37.7,8.28,30.2,0.006181000000000001,-0.13949000000000003,46.8,1.6831248945850326,8.834394268067237,1.6430417702969574e-09,0.3249935902307893,653.0548859635929,11.392939775827193,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-255W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,255.0,225.5,1.6236,1.64,0.99,60.0,8.89,37.3,8.51,30.0,0.006223000000000001,-0.13801,46.8,1.676893649010459,8.890002108275773,1.943867054321072e-09,0.23659798736570153,999976.5096466595,12.8541922948299,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-260W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,260.0,230.1,1.6236,1.64,0.99,60.0,9.01,38.0,8.5,30.6,0.006307000000000001,-0.1406,46.8,1.6966456995677428,9.01398570056524,1.6902992734153304e-09,0.2988391077171572,999999.9790703023,11.446629923589697,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-265W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,265.0,241.7,1.611,1.634,0.986,60.0,9.24,38.29,8.62,30.74,0.005091240000000001,-0.1198477,45.3,1.5446727283233364,9.255486837787197,1.556468661077318e-10,0.34630718452130127,206.61923930768444,8.745358377853027,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-270W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,270.0,246.4,1.611,1.634,0.986,60.0,9.31,38.72,8.72,30.97,0.00512981,-0.1211936,45.3,1.5556008518244169,9.321822526444434,1.4231488960450524e-10,0.36309869130662914,285.9328882651024,7.881062442965126,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-275W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,275.0,251.1,1.611,1.634,0.986,60.0,9.35,38.92,8.78,31.32,0.00515185,-0.12181960000000001,45.3,1.56692405149284,9.35906119135005,1.509420049200318e-10,0.337918586199003,348.68915157336625,8.349753732058682,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-280W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,280.0,255.9,1.611,1.634,0.986,60.0,9.23,39.26,9.03,31.01,0.00453193,-0.11660219999999999,45.2,1.5687748138693285,9.230341992630116,1.2483236711836171e-10,0.24388082487472046,6582.044395446449,12.649864445860452,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P30-280W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,280.0,255.8,1.611,1.634,0.986,60.0,9.47,39.16,8.84,31.68,0.005217970000000001,-0.12257079999999998,45.3,1.586088584287475,9.48439643745677,1.7605092778973691e-10,0.31344941611083327,206.18755016289003,9.61449003152215,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M30-285W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,285.0,260.6,1.611,1.634,0.986,60.0,9.46,39.18,8.95,31.85,0.004644860000000001,-0.11636459999999998,45.2,1.5661537382175192,9.462778871447195,1.2871362237429537e-10,0.2975363340535246,1012.8911744633473,12.71557651144978,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-320W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,320.0,291.9,1.923,1.95,0.986,72.0,9.24,45.94,8.62,37.13,0.005091240000000001,-0.14379219999999998,45.3,1.860305592462448,9.254708371282295,1.7077762443256198e-10,0.38160581121597426,239.73000540284048,9.564912317795025,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-325W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,325.0,296.6,1.923,1.95,0.986,72.0,9.28,46.31,8.72,37.28,0.0051132799999999996,-0.1449503,45.3,1.8641889568216912,9.28835329199161,1.4940956907757846e-10,0.40335905237801345,448.1074576007093,8.323936902723649,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,330.0,301.3,1.923,1.95,0.986,72.0,9.35,46.65,8.78,37.58,0.00515185,-0.1460145,45.3,1.879236148875064,9.359031535801751,1.531365241096485e-10,0.3997559733741521,413.8519552888802,8.476367540552259,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-335W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,335.0,306.2,1.923,1.95,0.986,72.0,9.33,46.75,8.83,37.94,0.00458103,-0.1388475,45.2,1.8667341309405134,9.332375059346226,1.2363153708213965e-10,0.36842483769075296,1447.2921123236022,12.473611912108678,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-335W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Multi-c-Si,0,335.0,306.0,1.923,1.95,0.986,72.0,9.47,46.83,8.84,37.9,0.005217970000000001,-0.1465779,45.3,1.8971690076214458,9.484347827000532,1.7701734397863063e-10,0.3728414201278564,246.0866363501428,9.663066143754932,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,340.0,310.9,1.923,1.95,0.986,72.0,9.41,46.91,8.91,38.17,0.00462031,-0.1393227,45.2,1.8753433612395454,9.412106523718492,1.2847959531082036e-10,0.3534256140129159,1578.7792844675862,12.744150108509919,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-345W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,345.0,315.6,1.923,1.95,0.986,72.0,9.48,47.13,8.99,38.38,0.0046546800000000004,-0.13997610000000002,45.2,1.8835293361086398,9.480872315807641,1.2861319780129548e-10,0.34850908786859136,3787.4664914270234,12.680248121507743,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,350.0,320.3,1.923,1.95,0.986,72.0,9.59,47.64,9.09,38.51,0.00470869,-0.1414908,45.2,1.896769971503945,9.59076429133492,1.184404368434309e-10,0.38489027526672265,4829.443829909236,11.829823670111146,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-355W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,355.0,328.4,1.78,,,60.0,11.24,40.3,10.54,33.7,0.00693508,-0.12593749999999998,45.4,1.5993674020210316,11.249860885514387,1.2575596667942346e-10,0.16215590670306437,184.83456055632814,5.3078096364956355,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-355W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,355.0,327.5,1.81,,,60.0,11.25,40.3,10.51,33.8,0.0062325,-0.1122758,46.0,1.5820674121480922,11.262132755583469,9.503872526927639e-11,0.15517143889465929,143.88147054481757,15.684015933070386,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-355W Black,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,355.0,331.1,1.83,,,40.0,11.25,40.3,10.51,33.8,0.0059625,-0.113243,44.2,1.5445127757747685,11.263361144128975,5.1100556853290356e-11,0.16303521403095028,137.27463427753585,9.118826409166019,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-360W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,360.0,333.1,1.78,,,60.0,11.33,40.5,10.62,33.9,0.0069906099999999995,-0.12656250000000002,45.4,1.6085137204875501,11.34000623678336,1.2911096058342643e-10,0.15801823389932998,178.92307309535389,5.465899455310446,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-360W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,360.0,332.2,1.81,,,60.0,11.35,40.5,10.59,34.0,0.0062879,-0.11283300000000002,46.0,1.591767334203999,11.36271125514716,9.860490354710674e-11,0.15083926337318254,134.68580758691422,15.951533243766043,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-360W Black,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,360.0,335.9,1.83,,,40.0,11.35,40.5,10.59,34.0,0.0060155,-0.11380500000000002,44.2,1.5539682011737326,11.363976164781905,5.304380624766523e-11,0.15870209830678145,128.88148207493782,9.375810810236858,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-365W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,365.0,337.9,1.78,,,60.0,11.41,40.7,10.71,34.1,0.00703997,-0.1271875,45.4,1.6161070898489036,11.419061113989244,1.2951857430795875e-10,0.15436771205725558,194.3840068754955,5.427924740171898,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,365.0,337.0,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0063322199999999995,-0.11339020000000001,46.0,1.5992338744726025,11.441735753316635,9.883882152273302e-11,0.14727260206241186,143.43568615318978,15.902164143097854,-0.3798,N,2025.7.3,6/23/2025,4.0,bootstrapping +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-365W Black,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,365.0,340.7,1.83,,,40.0,11.43,40.7,10.68,34.2,0.0060579,-0.11436700000000002,44.2,1.5612619148644942,11.442953832404886,5.316537385698562e-11,0.15510751240870377,136.8613415831665,9.328389567386376,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-370W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,370.0,342.6,1.78,,,60.0,11.5,40.9,10.79,34.3,0.0070955,-0.1278125,45.4,1.6252516759894493,11.509203377706894,1.3291880994183492e-10,0.15035429429508795,187.8738958913682,5.583665260789159,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-370W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,370.0,341.7,1.81,,,60.0,11.52,40.9,10.76,34.4,0.006382079999999999,-0.1139474,46.0,1.6082045160669267,11.531790121453808,1.0133077111036836e-10,0.14333958942289313,140.0555627907442,16.063890655763746,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-370W Black,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,370.0,345.5,1.83,,,40.0,11.52,40.9,10.76,34.4,0.0061056,-0.114929,44.2,1.5663711906150062,11.533137654869922,5.1313585984221295e-11,0.15191721746413944,133.211473171767,8.949116749615767,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,375.0,347.4,1.78,,,60.0,11.59,41.1,10.87,34.5,0.00715103,-0.1284375,45.4,1.6343955786653208,11.599330436057866,1.3637125044970799e-10,0.14640039183349143,181.85437165646778,5.73781088126199,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,375.0,346.5,1.81,,,60.0,11.6,41.1,10.84,34.6,0.0064264,-0.11450460000000001,46.0,1.518831389118631,11.614566272547847,1.9981205736965716e-11,0.15974444296484103,127.21412004161442,1.7295383138266751,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,375.0,350.3,1.83,,,40.0,11.6,41.1,10.84,34.6,0.006148,-0.11549100000000002,44.2,1.5780593666970166,11.612567083772003,5.5264497570365347e-11,0.14754752309515376,136.19319428997485,9.54054869590866,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,395.0,367.1,1.95,,,72.0,10.29,48.7,9.76,40.5,0.004383539999999999,-0.1270583,45.4,1.8221712137434154,10.294300844472021,2.5247516698559718e-11,0.2637231459080289,630.9717181712844,11.944328870797486,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,395.0,365.4,1.91,,,72.0,10.37,48.7,9.86,40.1,0.00432429,-0.1281784,46.5,1.818309850536994,10.37220443957253,2.4137825539809313e-11,0.306989980897316,1444.124986443158,10.483863418612984,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-400W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,400.0,371.8,1.95,,,72.0,10.33,48.9,9.81,40.8,0.00440058,-0.1275801,45.4,1.8316046053372685,10.33341025036577,2.610660155584484e-11,0.24823217369455688,751.9208677251013,12.208062661174639,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-400W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,400.0,370.2,1.91,,,72.0,10.45,49.0,9.93,40.3,0.00435765,-0.128968,46.5,1.8289600311250924,10.45270740739021,2.4114173226645323e-11,0.311947435085346,1204.0488850588736,10.408748611921862,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-405W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,405.0,376.6,1.95,,,72.0,10.37,49.1,9.86,41.1,0.00441762,-0.12810190000000002,45.4,1.8343666740226268,10.370006261875039,2.460410518378827e-11,0.23433319723697488,388072.52043026243,11.443974996866375,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,405.0,375.0,1.91,,,72.0,10.52,49.2,10.0,40.5,0.00438684,-0.1294944,46.5,1.8369371889036124,10.522451956209933,2.4465477950495426e-11,0.307057094349389,1317.4137345099691,10.47708957243731,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-410W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,410.0,381.4,1.95,,,72.0,10.41,49.3,9.91,41.4,0.00443466,-0.1286237,45.4,1.8504313824074166,10.411879461597461,2.787133610556779e-11,0.2177546142816728,1206.1037153092027,12.723887604395397,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-410W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,410.0,379.7,1.91,,,72.0,10.59,49.4,10.08,40.7,0.00441603,-0.1300208,46.5,1.8440511179566423,10.591351256342273,2.453848904446568e-11,0.30228053625110024,2369.0183075416217,10.438737825708738,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-430W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,430.0,397.8,2.14,,,72.0,11.3,48.9,10.6,40.6,0.0069721,-0.1528125,45.4,1.9326756634124558,11.310928284393885,1.1404038928125613e-10,0.2277652154600721,235.51244795616583,4.430655489224259,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-430W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,430.0,397.0,2.12,,,72.0,11.19,49.2,10.6,40.6,0.00619926,-0.13707120000000003,46.0,1.8928506328394044,11.190008032223083,5.759802713363736e-11,0.2671157720234987,372139.56764060614,11.060499713280672,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-435W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,435.0,402.6,2.14,,,72.0,11.36,49.1,10.67,40.8,0.007009119999999999,-0.1534375,45.4,1.9158700165796523,11.360008535834739,8.418886219753073e-11,0.2285194969675685,304136.0596349038,1.8041108343847618,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-435W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,435.0,401.8,2.12,,,72.0,11.26,49.4,10.67,40.8,0.00623804,-0.1376284,46.0,1.9099027953982157,11.264092436989776,6.545271689482414e-11,0.2611435229396352,718.5147218072802,12.177878922324936,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,440.0,407.3,2.14,,,72.0,11.45,49.3,10.74,41.0,0.00706465,-0.1540625,45.4,1.95033262365469,11.460842406593043,1.1832855635606487e-10,0.2192564944222948,231.54333048183614,4.63178500987107,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,440.0,406.6,2.12,,,72.0,11.33,49.6,10.74,41.0,0.00627682,-0.13818560000000002,46.0,1.9181787315679284,11.333833649164522,6.636503042647504e-11,0.2568537884106585,759.1079616257376,12.246040300477722,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-445W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,445.0,412.1,2.14,,,72.0,11.52,49.5,10.81,41.2,0.00710784,-0.1546875,45.4,1.9587140876399092,11.530486946512312,1.1982241125140214e-10,0.21524693804334077,236.45060032443345,4.685119371677367,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-445W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,445.0,411.3,2.12,,,72.0,11.4,49.8,10.81,41.2,0.0063156,-0.1387428,46.0,1.9264420399273052,11.403581888556193,6.727155677440849e-11,0.25262248620091615,804.0160442371421,12.312110025583475,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-450W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,450.0,416.9,2.14,,,72.0,11.58,49.6,10.87,41.4,0.007144859999999999,-0.15500000000000003,45.4,1.9653738386528081,11.589832309591014,1.2472102459577033e-10,0.20212800908067455,238.0562157327914,4.98011293526294,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W,Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd,Mono-c-Si,0,450.0,416.1,2.12,,,72.0,11.47,50.0,10.88,41.4,0.006354380000000001,-0.1393,46.0,1.9347057015998548,11.473336757338846,6.818380812434504e-11,0.2484459122756409,854.0251872127116,12.377680209828018,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-390P-54BB,AMPS Solar,Mono-c-Si,0,390.0,367.2,1.94,,,54.0,13.61,36.5,12.73,30.65,0.006446240400000001,-0.0963235,43.3,1.3437375630151378,13.627396397417812,2.1179894370113682e-11,0.12847733323998997,100.51371384881531,6.664223044673236,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-395P-54BB,AMPS Solar,Mono-c-Si,0,395.0,372.0,1.94,,,54.0,13.69,36.75,12.81,30.85,0.0064841316,-0.09698325000000001,43.3,1.352450269724152,13.707289146088348,2.1106001230641016e-11,0.12952653222346067,102.56251082977585,6.581358934710584,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-400P-54BB,AMPS Solar,Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.78,37.0,12.89,31.05,0.006526759200000001,-0.09764300000000001,43.3,1.3616503021343582,13.797766566521798,2.1237075102663315e-11,0.1304062000157196,101.14489148260813,6.579507399954591,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-405P-54BB,AMPS Solar,Mono-c-Si,0,405.0,381.7,1.94,,,54.0,13.86,37.25,12.97,31.24,0.0065646504,-0.09830275000000001,43.3,1.3701401366199268,13.877757617126347,2.1072609031070967e-11,0.13231566184503424,103.2737144276489,6.460221349479913,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-410P-54BB,AMPS Solar,Mono-c-Si,0,410.0,386.5,1.94,,,54.0,13.94,37.5,13.05,31.43,0.0066025416,-0.09896250000000001,43.3,1.378630394696281,13.95773791270358,2.0912393080743233e-11,0.1342016375092749,105.46736051757371,6.3425977139343335,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-425N-108BB,AMPS Solar,Mono-c-Si,1,425.0,403.8,1.94,,,54.0,13.89,39.36,12.95,32.86,0.0060690966,-0.090874368,43.2,1.3685530951131393,13.916725332696657,4.351457027788807e-12,0.16615207203995172,86.35448277634111,7.123216770330827,-0.29378,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-430N-108BB,AMPS Solar,Mono-c-Si,1,430.0,408.7,1.94,,,54.0,13.95,39.55,12.98,33.16,0.006095312999999999,-0.09131304,43.2,1.3792457524078423,13.976817419672475,4.746001976422964e-12,0.15373328129105207,79.96963547130657,7.864927788526885,-0.29378,N,2025.7.3,6/23/2025,4.0,bootstrapping +AMPS Solar AMPS-435N-108BB,AMPS Solar,Mono-c-Si,1,435.0,413.6,1.94,,,54.0,14.01,39.69,13.05,33.42,0.0061215294,-0.09163627199999999,43.2,1.3862566160308243,14.034012283340573,4.9854293735516796e-12,0.14123653852711,82.4046542449757,8.261416117754639,-0.29378,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-440N-108BB,AMPS Solar,Mono-c-Si,1,440.0,418.4,1.94,,,54.0,14.07,39.86,13.09,33.65,0.006147745800000001,-0.092028768,43.2,1.394709756739062,14.093855744528303,5.263429414828363e-12,0.1335921635188936,78.79199661023956,8.714524050571105,-0.29378,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-445N-108BB,AMPS Solar,Mono-c-Si,1,445.0,423.3,1.94,,,54.0,14.13,40.04,13.16,33.81,0.0061739622,-0.092444352,43.2,1.4004567458721133,14.153006944510444,5.233250550524068e-12,0.13301995853743653,81.69585555367738,8.62008384727315,-0.29378,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-450N-108BB,AMPS Solar,Mono-c-Si,1,450.0,428.2,1.94,,,54.0,14.19,40.16,13.23,34.03,0.006200178599999999,-0.09272140799999999,43.2,1.4062918034650662,14.210675181123557,5.4385800358651915e-12,0.12273940492850097,84.239753293241,8.922936649322507,-0.29378,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-525P-144SW,AMPS Solar,Mono-c-Si,1,525.0,494.3,2.56,,,72.0,13.87,48.43,12.94,40.6,0.0063826966,-0.12252790000000001,43.3,1.7835694733408591,13.890386137379565,2.173099568383954e-11,0.17302739736392667,117.7216637470036,11.383040348829782,-0.33477,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-530P-144SW,AMPS Solar,Mono-c-Si,1,530.0,499.1,2.56,,,72.0,13.94,48.55,12.98,40.86,0.0064149092,-0.1228315,43.3,1.7932445551865626,13.960420874422939,2.358706962066736e-11,0.15827216095142008,108.04208890148392,12.091153313007952,-0.33477,N,2025.7.3,6/23/2025,2.0,first_pass +AMPS Solar AMPS-530P-72BB,AMPS Solar,Mono-c-Si,0,530.0,499.4,2.56,,,72.0,13.72,49.32,12.83,41.32,0.006812391600000001,-0.122496084,43.3,1.811089377295338,13.73858170262534,1.9921490055669667e-11,0.1811812560878379,133.7771297617324,12.715744930708668,-0.33133,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-535P-144SW,AMPS Solar,Mono-c-Si,1,535.0,503.9,2.56,,,72.0,14.01,48.67,13.05,41.03,0.0064471218,-0.12313510000000001,43.3,1.7988780292225952,14.029530072441533,2.414474654541028e-11,0.15184863182577787,108.92941245402511,12.257294009911634,-0.33477,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-535P-72BB,AMPS Solar,Mono-c-Si,0,535.0,504.2,2.56,,,72.0,13.79,49.46,12.9,41.48,0.0068471487,-0.12284380200000002,43.3,1.816855127206752,13.808045590260871,2.0217957038410354e-11,0.17701208549433348,135.26831937467097,12.803337162397868,-0.33133,N,2025.7.3,6/23/2025,2.0,first_pass +AMPS Solar AMPS-540P-144SW,AMPS Solar,Mono-c-Si,1,540.0,508.7,2.56,,,72.0,14.06,48.81,13.14,41.13,0.0064701308,-0.12348930000000001,43.3,1.8007045380155042,14.077376731955683,2.3133144965063143e-11,0.1537515825138387,124.4047075328877,11.82052316739613,-0.33477,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-540P-72BB,AMPS Solar,Mono-c-Si,0,540.0,509.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.0068819058,-0.12319152000000001,43.3,1.8226209676638268,13.877518825871855,2.0517049385241935e-11,0.17288834794103777,136.7804285306627,12.890437869201259,-0.33133,N,2025.7.3,6/23/2025,2.0,first_pass +AMPS Solar AMPS-545P-144SW,AMPS Solar,Mono-c-Si,1,545.0,513.6,2.56,,,72.0,14.12,48.91,13.18,41.38,0.0064977416,-0.1237423,43.3,1.8091347370113837,14.136755751978038,2.489726513312446e-11,0.1388348608332176,116.99553939618171,12.457719955149901,-0.33477,N,2025.7.3,6/23/2025,2.0,first_pass +AMPS Solar AMPS-545P-72BB,AMPS Solar,Mono-c-Si,0,545.0,513.9,2.56,,,72.0,13.93,49.76,13.04,41.8,0.0069166629,-0.123588912,43.3,1.8287553700455768,13.947132192348612,2.0706282859360802e-11,0.17035494315380542,138.5137593017182,12.92714127413566,-0.33133,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-550P-144BB,AMPS Solar,Mono-c-Si,1,550.0,517.7,1.9,,,72.0,14.0,49.9,13.11,42.0,0.00868,-0.130738,46.8,1.8635376293632897,14.015382190593249,3.2107107187456895e-11,0.15799768906737063,143.80056234828933,10.672731758784796,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +AMPS Solar AMPS-550P-144SW,AMPS Solar,Mono-c-Si,1,550.0,518.4,2.56,,,72.0,14.18,49.05,13.25,41.55,0.006525352400000001,-0.1240965,43.3,1.8144964549853873,14.195652116077053,2.5099840564615034e-11,0.13433630084503334,121.70167549729031,12.488629973980734,-0.33477,N,2025.7.3,6/23/2025,2.0,first_pass +AMPS Solar AMPS-550P-72BB,AMPS Solar,Mono-c-Si,0,550.0,518.7,2.56,,,72.0,14.0,49.92,13.11,41.96,0.006951420000000001,-0.123986304,43.3,1.8348903774258818,14.01675171419422,2.0896313480474196e-11,0.1678485759267348,140.27699155208518,12.963682962333719,-0.33133,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-575N-144SW,AMPS Solar,Mono-c-Si,1,575.0,545.5,2.56,,,72.0,13.89,52.3,13.15,43.73,0.006562469400000001,-0.12084438,43.3,1.8375711178058423,13.90051436741773,5.976538031842811e-12,0.21050630125459197,278.0892483030634,9.742767517077748,-0.30465,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-580N-144SW,AMPS Solar,Mono-c-Si,1,580.0,550.3,2.56,,,72.0,13.95,52.5,13.22,43.88,0.006590817,-0.1213065,43.3,1.8434283947790582,13.95965283095772,5.9020155961075286e-12,0.2119439856627572,306.29549299362645,9.585853554374236,-0.30465,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-585N-144SW,AMPS Solar,Mono-c-Si,1,585.0,555.2,2.56,,,72.0,14.01,52.7,13.29,44.02,0.0066191646000000005,-0.12176862,43.3,1.8490931540262514,14.01879597973611,5.811765737940675e-12,0.21422154947056296,341.20632463794635,9.403500082839662,-0.30465,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-590N-144SW,AMPS Solar,Mono-c-Si,1,590.0,560.0,2.56,,,72.0,14.07,52.9,13.36,44.17,0.006647512200000001,-0.12223074,43.3,1.8549607186904697,14.077899966213161,5.741210548632604e-12,0.21562128874353548,384.02588625024487,9.250411342679405,-0.30465,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-595N-144SW,AMPS Solar,Mono-c-Si,1,595.0,564.9,2.56,,,72.0,14.13,53.1,13.43,44.31,0.006675859800000001,-0.12269286,43.3,1.8606361626257246,14.137000230499948,5.65540639118641e-12,0.2178524606760018,439.736276119777,9.072101394078222,-0.30465,N,2025.7.3,6/23/2025,4.0,first_pass +AMPS Solar AMPS-600N-144SW,AMPS Solar,Mono-c-Si,1,600.0,569.8,2.56,,,72.0,14.19,53.3,13.5,44.45,0.0067042074,-0.12315498,43.3,1.866316945875925,14.196077232188749,5.57187116277019e-12,0.22005878047511557,513.8250477264894,8.89583064579361,-0.30465,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM160-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,160.0,141.5,1.2766400000000002,1.58,0.808,72.0,5.12,42.42,4.57,35.01,0.0027648,-0.1556814,46.9,1.9135716179468134,5.137012673838599,1.1240430493991744e-09,0.38054768530018585,114.5266402476876,14.210231550808972,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM165-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,165.0,146.0,1.2766400000000002,1.58,0.808,72.0,5.22,42.5,4.66,35.4,0.0028187999999999998,-0.155975,46.9,1.9282738513469622,5.233491178522202,1.3008116353618869e-09,0.2907745545666975,112.50635721243118,15.403323771826445,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM170-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,170.0,150.5,1.2766400000000002,1.58,0.808,72.0,5.35,42.7,4.78,35.6,0.002889,-0.15670900000000001,46.9,1.937477554838117,5.363272108244072,1.336387990368479e-09,0.2772436890970629,111.75721906237577,15.42356790990617,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM175-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,175.0,155.1,1.2766400000000002,1.58,0.808,72.0,5.45,43.1,4.87,35.9,0.002943,-0.158177,46.9,1.9542961635515834,5.463894911737558,1.3414410061892728e-09,0.2830274978323659,111.01186328430526,15.283566790246127,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM180-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,180.0,159.6,1.2766400000000002,1.58,0.808,72.0,5.59,43.3,4.99,36.1,0.0030185999999999998,-0.158911,46.9,1.9658183020120763,5.604041498935805,1.4123868579769956e-09,0.2685271768656837,106.90219746172608,15.534421980387615,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM185-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,185.0,164.2,1.2766400000000002,1.58,0.808,72.0,5.72,43.4,5.11,36.2,0.0030888,-0.159278,46.9,1.9699521697356026,5.734007262935525,1.4399783621069752e-09,0.2596474620226947,106.02954063399838,15.497686016250396,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM190-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,190.0,168.8,1.2766400000000002,1.58,0.808,72.0,5.86,43.5,5.23,36.3,0.0031644000000000004,-0.159645,46.9,1.9763029915405417,5.874325806885137,1.5034601916375026e-09,0.24960066927299854,102.09966544493749,15.680380247986113,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM195-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,195.0,173.4,1.2766400000000002,1.58,0.808,72.0,6.01,43.6,5.37,36.3,0.0032454,-0.160012,46.9,1.9764915794126194,6.025553646223303,1.4713743697395375e-09,0.2632579413960878,101.72408377260064,15.233104117255522,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM200-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,200.0,178.0,1.2766400000000002,1.58,0.808,72.0,5.95,45.7,5.54,36.12,0.003213,-0.167719,46.9,1.957812602304202,5.95914007694345,4.270822304138361e-10,0.7158490077027058,466.0029859729094,4.142643245474759,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP205-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,205.0,182.3,1.6268799999999999,1.64,0.992,60.0,7.84,35.1,7.0,29.3,0.0057231999999999995,-0.12671100000000002,46.9,1.584421834971646,7.859331036247245,1.7447794353641577e-09,0.1521106983424338,61.69084684856957,16.041961407412145,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP210-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,210.0,186.9,1.6268799999999999,1.64,0.992,60.0,8.01,35.2,7.14,29.4,0.0058473,-0.12707200000000002,46.9,1.591171126069784,8.029817239411404,1.8351381920547153e-09,0.14590995505601742,58.97586606666385,16.32397675778964,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP215-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,215.0,191.5,1.6268799999999999,1.64,0.992,60.0,8.16,35.4,7.29,29.5,0.0059568,-0.127794,46.9,1.5956492427194262,8.18106561972351,1.760155240970974e-09,0.15587932942268898,60.38158261353579,15.74263191898927,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM220-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,220.0,197.6,1.6268799999999999,1.64,0.992,60.0,7.98,36.29,7.46,29.5,0.0026547066000000004,-0.118682816,45.2,1.5181416652178479,7.989192468767831,3.263103088085172e-10,0.3097527437040337,268.89699779991753,12.00736970840928,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP220-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,220.0,196.0,1.6268799999999999,1.64,0.992,60.0,8.32,35.4,7.46,29.5,0.0060736,-0.127794,46.9,1.5919946605871147,8.340368349342421,1.7131536076408722e-09,0.15416040416141177,62.97096905674228,15.29139566142992,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM225-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,225.0,202.2,1.6268799999999999,1.64,0.992,60.0,8.13,36.41,7.6,29.6,0.0027046071000000004,-0.11907526399999999,45.2,1.5232584356769,8.13937889430422,3.3293404909406647e-10,0.3046596628622229,264.0911964447792,12.020802964423625,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP225-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,225.0,200.6,1.6268799999999999,1.64,0.992,60.0,8.46,35.8,7.6,29.6,0.0061758,-0.129238,46.9,1.6001707670332923,8.48479763252481,1.5247860341670859e-09,0.1906341101462492,65.03704509540236,14.031873211466827,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM230-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,230.0,206.8,1.6268799999999999,1.64,0.992,60.0,8.29,36.53,7.74,29.7,0.0027578342999999995,-0.119467712,45.2,1.5293662315196268,8.30042878429086,3.4479304004293533e-10,0.2992724824486537,237.89630163498921,12.165731700120249,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP230-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,230.0,205.2,1.6268799999999999,1.64,0.992,60.0,8.6,36.0,7.72,29.8,0.006277999999999999,-0.12996,46.9,1.6110308880680133,8.62481163867986,1.5902610583107454e-09,0.1829988540790634,63.42951920449055,14.274100001303365,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM235-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,235.0,211.4,1.6268799999999999,1.64,0.992,60.0,8.44,36.65,7.89,29.8,0.0028077348,-0.11986016,45.2,1.5334218258856882,8.449703050254469,3.462949869166135e-10,0.29467573124033053,256.3177008102238,12.038121483762742,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP235-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,235.0,209.8,1.6268799999999999,1.64,0.992,60.0,8.75,36.1,7.83,30.0,0.0063875,-0.13032100000000002,46.9,1.6226711791729347,8.773924344688087,1.778180147040003e-09,0.16152455929701484,59.07539198595851,15.172229393883987,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM240-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,240.0,216.0,1.6268799999999999,1.64,0.992,60.0,8.59,36.78,8.03,29.9,0.0028576353,-0.120285312,45.2,1.538715580704675,8.599913074777401,3.516503736620963e-10,0.29139195990919975,252.50060640680283,12.017684785428028,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP240-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,240.0,214.4,1.6268799999999999,1.64,0.992,60.0,8.9,36.2,7.95,30.2,0.006497,-0.13068200000000002,46.9,1.6329884867052529,8.922238392150069,1.952872499697838e-09,0.14109127722590828,56.46597498798102,15.905856112255071,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM245-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,245.0,220.6,1.6268799999999999,1.64,0.992,60.0,8.71,37.02,8.14,30.1,0.0028975557000000002,-0.12107020800000001,45.2,1.5491231199294604,8.720235137805838,3.584664589243869e-10,0.28851883640797105,245.52668175933164,12.066844700627488,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP245-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,245.0,219.0,1.6268799999999999,1.64,0.992,60.0,9.06,36.4,8.09,30.3,0.0066137999999999995,-0.131404,46.9,1.640106614301625,9.084349431744005,1.937080264424992e-09,0.14911651702043394,55.483667784372535,15.659766783292083,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM250-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,250.0,225.3,1.6268799999999999,1.64,0.992,60.0,8.86,37.15,8.28,30.2,0.0029474562,-0.12149536,45.2,1.5544129875246344,8.87044622499962,3.637978455526998e-10,0.28544007167891106,242.0969675892204,12.046007940511803,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP250-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,250.0,223.6,1.6268799999999999,1.64,0.992,60.0,9.21,36.5,8.22,30.4,0.006723300000000001,-0.131765,46.9,1.6456846007119588,9.234509132945453,1.99653963253373e-09,0.14449689609914992,54.298801634335945,15.792514218540076,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM255-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,255.0,229.9,1.6268799999999999,1.64,0.992,60.0,8.92,37.64,8.33,30.6,0.0029674163999999998,-0.123097856,45.2,1.5755812092434194,8.931066037373952,3.6965551265733824e-10,0.2869561691920244,231.3067714511412,12.132168055375255,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP255-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,255.0,231.0,1.6268799999999999,1.64,0.992,60.0,8.95,37.52,8.36,30.5,0.0050174595,-0.12389104000000001,45.4,1.561342649974273,8.961223050426641,3.221150065499426e-10,0.2876710384330794,229.40787099712693,9.53303040571643,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP255-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,255.0,227.1,1.9403519999999999,1.956,0.992,72.0,8.13,42.1,7.26,35.1,0.005934900000000001,-0.151981,46.9,1.8987490599726646,8.150808794399527,1.7752870991333235e-09,0.18313129674006895,71.54944039955652,15.8604256465111,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM260-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,260.0,234.5,1.6268799999999999,1.64,0.992,60.0,9.15,37.39,8.55,30.4,0.0030439305000000004,-0.122280256,45.2,1.56469970645009,9.160864776608486,3.7705213148556963e-10,0.27749252491525417,233.69619580412802,12.078821570766184,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP260-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,260.0,235.7,1.6268799999999999,1.64,0.992,60.0,9.09,37.64,8.5,30.6,0.0050959449,-0.12428728,45.4,1.5655006740108741,9.100540793053716,3.234001835718695e-10,0.28389831818496897,244.82370841361526,9.427056405871049,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP260-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,260.0,231.6,1.9403519999999999,1.956,0.992,72.0,8.27,42.2,7.39,35.2,0.006037099999999999,-0.152342,46.9,1.9030115312312568,8.290660228787393,1.8020506526592304e-09,0.1780614885814305,71.27552534446714,15.8385299101924,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM265-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,265.0,239.2,1.6268799999999999,1.64,0.992,60.0,9.3,37.52,8.69,30.5,0.0030938310000000004,-0.12270540800000002,45.2,1.569987336371577,9.311076943981966,3.82343721270308e-10,0.2747376275475331,230.6647304030792,12.057859294993527,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP265-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,265.0,240.4,1.6268799999999999,1.64,0.992,60.0,9.24,37.76,8.63,30.7,0.005180036400000001,-0.12468351999999999,45.4,1.571560316848018,9.251650288679004,3.336790702512823e-10,0.279746228926631,221.87050774164456,9.563396286165107,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP265-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,265.0,236.2,1.9403519999999999,1.956,0.992,72.0,8.41,42.3,7.51,35.3,0.0061393,-0.15270299999999998,46.9,1.9089087629282846,8.430892073817539,1.8606966476412973e-09,0.17258229680884177,69.47214891508854,15.985647643577542,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM270-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,270.0,243.8,1.6268799999999999,1.64,0.992,60.0,9.44,37.64,8.82,30.6,0.0031404047999999997,-0.123097856,45.2,1.5751595417493114,9.451310002901181,3.8894249065749953e-10,0.27119283890953616,226.35368369896835,12.077831779044518,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM270-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,270.0,242.0,1.9403519999999999,1.956,0.992,72.0,8.14,43.67,7.61,35.5,0.003430684400000001,-0.147984529,45.7,1.842300128845989,8.148953065547287,4.068271804470475e-10,0.3610901225894884,328.2980681071274,9.73499006372492,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP270-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,270.0,245.0,1.6268799999999999,1.64,0.992,60.0,9.38,37.88,8.77,30.8,0.005258521800000001,-0.12507976,45.4,1.5757390183873736,9.390969747272376,3.349661389442905e-10,0.2762073494999504,236.1791210208394,9.4606151588839,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP270-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,270.0,240.8,1.9403519999999999,1.956,0.992,72.0,8.57,42.4,7.65,35.3,0.0062561,-0.15306399999999998,46.9,1.9110310948345741,8.593029102402365,1.8438823030917027e-09,0.1826374107277506,67.96629505973884,15.720493109784588,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM275-60,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,275.0,248.5,1.6268799999999999,1.64,0.992,60.0,9.55,37.88,8.93,30.8,0.0031769985000000005,-0.12388275200000001,45.2,1.5846591056032275,9.560766926674654,3.9063044164525735e-10,0.2692025551691607,238.776108202226,12.00922531098338,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM275-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,275.0,246.6,1.9403519999999999,1.956,0.992,72.0,8.27,43.79,7.73,35.6,0.0034854742,-0.14839117300000002,45.7,1.8476349551580964,8.27922909502378,4.1466969678632193e-10,0.3559915625005371,318.99668740426915,9.76453617478839,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP275-60,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,275.0,249.7,1.6268799999999999,1.64,0.992,60.0,9.52,38.01,8.9,30.9,0.0053370072,-0.12550902,45.4,1.581063981528766,9.531234414850037,3.395043059148365e-10,0.27382628392218233,232.0393754902321,9.448904643216432,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP275-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,275.0,245.4,1.9403519999999999,1.956,0.992,72.0,8.68,42.6,7.75,35.5,0.0063364,-0.153786,46.9,1.9209042530539748,8.702592523134951,1.886514251575708e-09,0.17610361038251038,67.65864459548811,15.816101619342879,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM280-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,280.0,251.2,1.9403519999999999,1.956,0.992,72.0,8.39,43.91,7.84,35.7,0.0035360494000000004,-0.148797817,45.7,1.8530487190263203,8.399552340840652,4.224346110850486e-10,0.3514592388010472,308.6932900911547,9.80232685407867,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP280-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,280.0,249.9,1.9403519999999999,1.956,0.992,72.0,8.78,42.8,7.84,35.7,0.006409399999999999,-0.15450799999999998,46.9,1.9309477382927445,8.802166931978306,1.9308695308930793e-09,0.1698719536269414,67.28382197295447,15.92820264786345,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM285-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,285.0,255.8,1.9403519999999999,1.956,0.992,72.0,8.52,44.03,7.96,35.8,0.0035908392000000003,-0.149204461,45.7,1.8583732390816239,8.52982732590714,4.3030790843138843e-10,0.34665798057412245,300.54223568196846,9.83043376813922,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP285-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,285.0,254.5,1.9403519999999999,1.956,0.992,72.0,8.89,43.1,7.94,35.9,0.0064897,-0.155591,46.9,1.942493521541364,8.913366842148477,1.9120029313996682e-09,0.1765985378798369,67.18756228539148,15.715425414316297,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM290-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,290.0,260.5,1.9403519999999999,1.956,0.992,72.0,8.64,44.16,8.08,35.9,0.0036414144000000005,-0.149644992,45.7,1.8627305118309267,8.649267605700897,4.3065403203247346e-10,0.34379721964801835,320.5152026946695,9.709946136263309,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP290-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,290.0,259.1,1.9403519999999999,1.956,0.992,72.0,9.01,43.2,8.05,36.0,0.0065772999999999995,-0.155952,46.9,1.9471371777134565,9.033234606256077,1.941569129810746e-09,0.1723109850850946,66.8193864566691,15.732940784938263,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM295-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,295.0,265.1,1.9403519999999999,1.956,0.992,72.0,8.77,44.28,8.19,36.0,0.0036962042000000003,-0.15005163600000002,45.7,1.8692676629022453,8.780445929190417,4.446354973515395e-10,0.33910737128537666,284.7015413991155,9.866014363764021,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP295-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,295.0,263.7,1.9403519999999999,1.956,0.992,72.0,9.15,43.3,8.17,36.1,0.0066795000000000005,-0.15631299999999998,46.9,1.9529827464283445,9.17346278202566,2.0003204441945124e-09,0.16738250284870218,65.27572283826318,15.871683087064829,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM300-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,300.0,269.7,1.9403519999999999,1.956,0.992,72.0,8.31,44.4,8.31,36.1,0.0035023326000000006,-0.15045828,45.7,1.909474666523626,8.310000489909621,6.624908171637806e-10,0.0589267707945775,999991.8946172242,13.898070531933502,-0.46757,N,2025.7.3,6/23/2025,2.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP300-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,300.0,268.3,1.9403519999999999,1.956,0.992,72.0,9.27,43.4,8.28,36.2,0.006767099999999999,-0.15667399999999998,46.9,1.9576317818209548,9.293317838960496,2.0304956103358217e-09,0.16333432355731067,64.93351874452586,15.889297475175331,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM305-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,305.0,274.3,1.9403519999999999,1.956,0.992,72.0,9.02,44.53,8.43,36.2,0.0038015692000000004,-0.15089881100000002,45.7,1.8789336119727154,9.03016292182472,4.5264466151316385e-10,0.33211685641734573,294.7670582509233,9.772199649227,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP305-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,305.0,276.4,1.9403519999999999,1.956,0.992,72.0,9.02,44.53,8.43,36.2,0.0050567022,-0.14703806,45.4,1.852558686245452,9.030881395612978,3.2276425639053824e-10,0.33860375756582295,280.6814798317919,9.479950616239726,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM310-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,310.0,278.9,1.9403519999999999,1.956,0.992,72.0,9.14,44.65,8.54,36.3,0.0038521444000000006,-0.151305455,45.7,1.8843277445133477,9.150485834439527,4.6043642078381276e-10,0.32827209150783954,286.1391190433807,9.80728722159685,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP310-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,310.0,281.0,1.9403519999999999,1.956,0.992,72.0,9.14,44.65,8.54,36.3,0.0051239754,-0.1474343,45.4,1.8578725867580448,9.151217122669522,3.2832070324809055e-10,0.3346955987085895,272.71861398124537,9.514968712410521,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM315-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,315.0,283.6,1.9403519999999999,1.956,0.992,72.0,9.26,44.77,8.65,36.4,0.0039027196000000004,-0.15171209900000002,45.7,1.8897169035384906,9.270808135844383,4.682448784033475e-10,0.3245272416181283,278.04264889493794,9.841667300995232,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP315-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,315.0,285.7,1.9403519999999999,1.956,0.992,72.0,9.26,44.77,8.65,36.4,0.0051912486,-0.14783054,45.4,1.863181986233522,9.27155222391847,3.338905130595119e-10,0.3308888479128542,265.2330081363361,9.549318586209909,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM320-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,320.0,288.2,1.9403519999999999,1.956,0.992,72.0,9.38,44.9,8.77,36.5,0.003953294800000001,-0.15215263,45.7,1.8941073173547356,9.390250021532447,4.683630780165333e-10,0.32217526333817575,294.8290886617936,9.726403492048815,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP320-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,320.0,290.3,1.9403519999999999,1.956,0.992,72.0,9.38,44.9,8.77,36.5,0.005258521800000001,-0.1482598,45.4,1.8675254202643632,9.39099114407037,3.339720840846398e-10,0.32845895593865465,280.3116200339704,9.434259346160417,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM325-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,325.0,292.9,1.9403519999999999,1.956,0.992,72.0,9.48,45.14,8.86,36.7,0.0039954408000000005,-0.152965918,45.7,1.9047860395859588,9.490662327364856,4.764010113812689e-10,0.31978343733777803,284.32324501187804,9.784713777220531,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP325-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,325.0,295.0,1.9403519999999999,1.956,0.992,72.0,9.5,45.02,8.88,36.6,0.005325795,-0.14865604000000002,45.4,1.8728355949024291,9.511327155461144,3.3952992515729743e-10,0.3248277192253977,272.4305966955833,9.468716241136446,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJM330-72,Anhui Rinengzhongtian Semiconductor Development,Mono-c-Si,0,330.0,297.5,1.9403519999999999,1.956,0.992,72.0,9.6,45.26,8.97,36.8,0.004046016,-0.153372562,45.7,1.9101713441223536,9.610984532358474,4.842177425744234e-10,0.3162778827605336,276.41305490133743,9.818383686754645,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development QJP330-72,Anhui Rinengzhongtian Semiconductor Development,Multi-c-Si,0,330.0,299.7,1.9403519999999999,1.956,0.992,72.0,9.62,45.14,8.99,36.7,0.0053930682,-0.14905228,45.4,1.8781412048630552,9.63166255413521,3.450995500740227e-10,0.32128724185812896,265.0177321994458,9.502503900078596,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM335-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,335.0,304.6,1.940352,,,72.0,9.335,46.848,8.724,38.4,0.004974808200000001,-0.1594799616,45.8,1.9329994225854843,9.345991957176382,2.7333237474942617e-10,0.30767503999296714,261.2952994908549,4.504257892543162,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,340.0,309.3,1.940352,,,72.0,9.449,46.97,8.831,38.5,0.005035561080000001,-0.159895274,45.8,1.9379785031625818,9.460088735412143,2.7649811438810116e-10,0.30476206052864047,259.69570454166535,4.498822875800415,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM345-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,345.0,314.0,1.940352,,,72.0,9.563,47.092,8.938,38.6,0.00509631396,-0.1603105864,45.8,1.9429586190962842,9.574185511952066,2.796639842920698e-10,0.30191838810577987,258.12370498572085,4.493518689182583,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM350-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,350.0,318.7,1.940352,,,72.0,9.677,47.214,9.044,38.7,0.005157066839999999,-0.1607258988,45.8,1.94805616469956,9.688363438061808,2.832026863151908e-10,0.29912606774836925,254.73304618479807,4.499834677855507,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM355-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,355.0,323.4,1.940352,,,72.0,9.79,47.336,9.149,38.8,0.005217286799999999,-0.1611412112,45.8,1.9531601205127327,9.801545495319367,2.8673672894897025e-10,0.296428196933306,251.3562401585921,4.506748437252238,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,360.0,328.1,1.940352,,,72.0,9.902,47.458,9.254,38.9,0.00527697384,-0.1615565236,45.8,1.9581559144925644,9.913650541756747,2.8989269211391006e-10,0.2938356614039782,249.7361089929216,4.503003675340549,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM365-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,365.0,332.8,1.940352,,,72.0,10.014,47.58,9.359,39.0,0.005336660879999999,-0.161971836,45.8,1.9631523721223678,10.025755587349554,2.9304871913807374e-10,0.291301029692477,248.14487539564604,4.499343626963277,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM370-72,Anhui Rinengzhongtian Semiconductor Development Co Ltd,Mono-c-Si,0,370.0,337.5,1.940352,,,72.0,10.125,47.702,9.463,39.1,0.005395815,-0.1623871484,45.8,1.9681568213318001,10.136864766094003,2.9619992735945964e-10,0.28884997251477285,246.49505569477625,4.4964842682940835,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Dasol Solar Energy Science & Technology DS-A4-210,Anji Dasol Solar Energy Science & Technology,Multi-c-Si,0,210.0,182.7,1.64672,1.66,0.992,60.0,8.0,36.1,7.19,29.2,0.006956521739130435,-0.13969130434782612,48.6,1.6818684908619017,8.030522041885966,3.5979233871048876e-09,0.2855783768745001,74.85173496056093,14.410835895190132,-0.5053251649387371,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Dasol Solar Energy Science & Technology DS-A4-215,Anji Dasol Solar Energy Science & Technology,Multi-c-Si,0,215.0,187.2,1.64672,1.66,0.992,60.0,8.0,36.3,7.31,29.4,0.006956521739130435,-0.14046521739130435,48.6,1.6756121040671352,8.01997724207371,3.0069610649879097e-09,0.2844472337723915,113.90855910856672,12.682714140624384,-0.5053251649387371,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Dasol Solar Energy Science & Technology DS-A4-220,Anji Dasol Solar Energy Science & Technology,Multi-c-Si,0,220.0,191.7,1.64672,1.66,0.992,60.0,8.1,36.5,7.44,29.6,0.007043478260869565,-0.14123913043478262,48.6,1.6809998349412145,8.116671564448403,2.9153189864795996e-09,0.27737000694840835,134.76228734028555,12.265861197198728,-0.5053251649387371,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Dasol Solar Energy Science & Technology DS-A4-225,Anji Dasol Solar Energy Science & Technology,Multi-c-Si,0,225.0,196.2,1.64672,1.66,0.992,60.0,8.2,36.7,7.55,29.8,0.007130434782608695,-0.1420130434782609,48.6,1.689160201413149,8.215104592298209,2.9197816525471084e-09,0.26994253448119593,146.54681818927526,12.159932692211862,-0.5053251649387371,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Dasol Solar Energy Science & Technology DS-A4-230,Anji Dasol Solar Energy Science & Technology,Multi-c-Si,0,230.0,200.7,1.64672,1.66,0.992,60.0,8.3,36.9,7.67,30.0,0.0072173913043478265,-0.14278695652173914,48.6,1.6960611430231243,8.312808204124789,2.881695552709842e-09,0.26297402648707524,170.41309506650651,11.916389931879513,-0.5053251649387371,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-S572-175,Anji Technology,Mono-c-Si,0,175.0,151.2,1.3002,1.576,0.825,72.0,5.17,43.99,4.78,36.63,0.0021455500000000004,-0.15906784,49.9,1.9749354507049433,5.175793567566411,1.0648790131630804e-09,0.3196218453123019,285.22068981245434,15.34075110425485,-0.5072,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-S572-180,Anji Technology,Mono-c-Si,0,180.0,155.7,1.3002,1.576,0.825,72.0,5.31,44.06,4.9,36.72,0.0022036499999999997,-0.15932096,49.9,1.9814000532236133,5.316247704354486,1.132591202034061e-09,0.3028920572519131,257.43170572680543,15.677003442087557,-0.5072,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-S572-185,Anji Technology,Mono-c-Si,0,185.0,160.2,1.3002,1.576,0.825,72.0,5.43,44.14,5.03,36.72,0.00225345,-0.15961024,49.9,1.9782736802264054,5.435765316058361,1.0790709482797594e-09,0.3146579679505818,296.35724865506114,14.997152355765943,-0.5072,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-220,Anji Technology,Multi-c-Si,0,220.0,189.1,1.62384,1.632,0.995,60.0,7.95,36.06,7.3,30.12,0.0043566,-0.13068144,50.2,1.665488098707161,7.95926580384981,3.029944061980341e-09,0.14254324839111823,122.30122763924291,20.89323260900283,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-225,Anji Technology,Multi-c-Si,0,225.0,193.5,1.62384,1.632,0.995,60.0,8.04,36.24,7.44,30.24,0.00440592,-0.13133376,50.2,1.6649572009869715,8.047361942260473,2.7573475848458835e-09,0.14925838632998756,163.00561128604508,19.821127186756815,-0.5196,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-230,Anji Technology,Multi-c-Si,0,230.0,204.1,1.62384,1.632,0.995,60.0,8.1,36.42,7.58,30.36,0.007857000000000001,-0.1307478,46.4,1.6702892659376798,8.103778708543683,2.711100145652815e-09,0.15481039111985184,331.85019694917526,20.232095620614807,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-235,Anji Technology,Multi-c-Si,0,235.0,208.7,1.62384,1.632,0.995,60.0,8.23,36.72,7.68,30.6,0.007983100000000002,-0.1318248,46.4,1.6864372526434073,8.234831998220518,2.8315243650201676e-09,0.1543152831803429,262.8344545597219,20.515494661942295,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-240,Anji Technology,Multi-c-Si,0,240.0,213.3,1.62384,1.632,0.995,60.0,8.32,36.84,7.83,30.72,0.008070400000000002,-0.13225560000000003,46.4,1.684453277903026,8.321897917570846,2.6245785613114277e-09,0.15263178952018067,669.1009580115356,19.62612797921077,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-245,Anji Technology,Multi-c-Si,0,245.0,217.9,1.62384,1.632,0.995,60.0,8.43,37.08,7.94,30.84,0.0081771,-0.1331172,46.4,1.6920465327176228,8.43167179491861,2.5488252320808963e-09,0.16383582445606468,826.1411439380156,19.204669583211796,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Anji Technology AJP-M660-250,Anji Technology,Multi-c-Si,0,250.0,222.4,1.62384,1.632,0.995,60.0,8.5,37.32,8.03,31.14,0.008245,-0.1339788,46.4,1.7033719548553554,8.500568695425608,2.5907537778273343e-09,0.14952402228736789,2234.870463898072,19.27410938465312,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M660BH-350BB,Apollo Renewables Inc,Mono-c-Si,0,350.0,327.3,1.8,,,60.0,11.15,40.1,10.42,33.6,0.00531855,-0.10526250000000001,43.5,1.5240840634257653,11.163691869521719,4.071033120340387e-11,0.1697932939809924,138.2714930746793,14.894306345040224,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M660BH-355BB,Apollo Renewables Inc,Mono-c-Si,0,355.0,332.0,1.8,,,60.0,11.25,40.3,10.51,33.8,0.00536625,-0.10578749999999999,43.5,1.5326983219901262,11.263761342929412,4.177581542609089e-11,0.1655239086023459,135.31702499729136,15.05329287041744,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M660BH-360BB,Apollo Renewables Inc,Mono-c-Si,0,360.0,336.8,1.8,,,60.0,11.35,40.5,10.59,34.0,0.00541395,-0.10631250000000002,43.5,1.542045660461588,11.364389131110658,4.334814461077241e-11,0.16119702215738577,127.1505694076516,15.320947792004397,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M660BH-365BB,Apollo Renewables Inc,Mono-c-Si,0,365.0,341.6,1.8,,,60.0,11.43,40.7,10.68,34.2,0.00545211,-0.10683750000000002,43.5,1.5492884176121564,11.443351891938109,4.344901463456606e-11,0.1575928342742708,134.90867938347392,15.271055482636111,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M660BH-370BB,Apollo Renewables Inc,Mono-c-Si,0,370.0,346.4,1.8,,,60.0,11.52,40.9,10.76,34.4,0.00549504,-0.1073625,43.5,1.5579486070533195,11.533418824777867,4.45471467456854e-11,0.15365454664912367,131.91172991121894,15.432716884466485,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M754BH-385BB,Apollo Renewables Inc,Mono-c-Si,0,385.0,360.5,1.94,,,54.0,13.52,36.7,12.65,30.44,0.006111039999999999,-0.09747520000000001,43.2,1.385160062355177,13.538649922957216,4.1153910419914144e-11,0.15692072383776007,113.75753163277635,11.909730098401939,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M754BH-390BB,Apollo Renewables Inc,Mono-c-Si,0,390.0,365.3,1.94,,,54.0,13.61,36.85,12.73,30.64,0.006151719999999999,-0.0978736,43.2,1.3928289777648524,13.628394257168182,4.3013225124001666e-11,0.14964479011552428,110.72290617281496,12.252456193897407,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M754BH-395BB,Apollo Renewables Inc,Mono-c-Si,0,395.0,370.1,1.94,,,54.0,13.7,36.98,12.81,30.84,0.006192399999999999,-0.09821888,43.2,1.400132290252665,13.717927166736967,4.526695069658433e-11,0.14088294468971818,107.66321226528237,12.659391660644484,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M754BH-400BB,Apollo Renewables Inc,Mono-c-Si,0,400.0,374.9,1.94,,,54.0,13.79,37.07,12.9,31.01,0.006233079999999999,-0.09845792,43.2,1.4054515069103215,13.806735574619301,4.724225370216593e-11,0.13185111653059117,108.64442678538741,12.988341022985106,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M672BH-435TW,Apollo Renewables Inc,Mono-c-Si,0,435.0,406.2,2.15,,,72.0,11.36,49.1,10.66,40.8,0.00518016,-0.13585970000000003,43.0,1.90271687762065,11.371606562870653,6.924895370490408e-11,0.23165275771165703,226.73166930038607,13.558001821198156,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M672BH-440TW,Apollo Renewables Inc,Mono-c-Si,0,440.0,411.0,2.15,,,72.0,11.48,49.2,10.73,41.0,0.005234880000000001,-0.13613640000000002,43.0,1.9133284533136257,11.493999144044237,7.625599124479276e-11,0.2165560821071061,177.58684751351547,14.365557584597775,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M672BH-445TW,Apollo Renewables Inc,Mono-c-Si,0,445.0,415.8,2.15,,,72.0,11.52,49.4,10.8,41.2,0.00525312,-0.1366898,43.0,1.9189657884295792,11.531766339480388,7.46187256836117e-11,0.21354850776439233,209.07767060162277,14.120644778199635,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M672BH-450TW,Apollo Renewables Inc,Mono-c-Si,0,450.0,420.6,2.15,,,72.0,11.58,49.6,10.87,41.4,0.005280480000000001,-0.1372432,43.0,1.8758759323090257,11.592125646542788,3.733025345259817e-11,0.22014386128728836,210.23752650297712,7.874093762263824,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M672BH-455TW,Apollo Renewables Inc,Mono-c-Si,0,455.0,425.4,2.15,,,72.0,11.65,49.8,10.93,41.6,0.0053124,-0.1377966,43.0,1.8984428668720983,11.65000561036048,4.719526185987739e-11,0.21295336603044282,442210.96936212893,9.809477736845913,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M772BH-530TW,Apollo Renewables Inc,Mono-c-Si,1,530.0,495.4,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005158720000000001,-0.1415896,43.4,1.888184922346985,13.735841295561363,6.132423347206979e-11,0.16702710468948026,144.66063654085997,6.80265435007689,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M772BH-535TW,Apollo Renewables Inc,Mono-c-Si,1,535.0,500.2,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00518504,-0.14202040000000002,43.4,1.8944176670174329,13.80540248776825,6.207377196480134e-11,0.1636604852217208,146.5268563133717,6.862246691937211,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +Apollo Renewables Inc Apollo-M772BH-540TW,Apollo Renewables Inc,Mono-c-Si,1,540.0,505.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00521136,-0.14245120000000003,43.4,1.9008928935341285,13.874899036346813,6.303591005096584e-11,0.15943986058414367,148.32076631161073,6.950044601793042,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +Apollo Renewables Inc Apollo-M772BH-545TW,Apollo Renewables Inc,Mono-c-Si,1,545.0,509.8,2.56,,,72.0,13.93,49.75,13.04,41.8,0.005237680000000001,-0.142882,43.4,1.9071263690630793,13.944476983961318,6.379693912914697e-11,0.15615061166153227,150.250773687383,7.008901886626917,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +Apollo Renewables Inc Apollo-M772BH-550TW,Apollo Renewables Inc,Mono-c-Si,1,550.0,514.6,2.56,,,72.0,14.0,49.9,13.11,41.96,0.0052640000000000004,-0.14331280000000002,43.4,1.9133603276024922,14.014062668425538,6.456293321388674e-11,0.15289665107101227,152.215288768733,7.067454389293538,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AP130,APOS Energy,Multi-c-Si,0,130.0,115.4,1.0230000000000001,1.5,0.682,36.0,7.86,22.07,7.43,17.38,0.0096678,-0.0653272,49.1,0.9205065528678416,7.876076605606811,3.0457547917132335e-10,0.27551833364548933,999999.9553359149,22.194777117082577,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AP135,APOS Energy,Multi-c-Si,0,135.0,119.9,1.0230000000000001,1.5,0.682,36.0,7.94,22.21,7.54,17.58,0.009766200000000001,-0.0657416,49.1,0.9313833789033104,7.9400019473037755,3.4956265108140573e-10,0.24493343958781763,999986.1484463284,23.495642074900445,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS135,APOS Energy,Mono-c-Si,0,135.0,120.9,1.0230000000000001,1.5,0.682,36.0,8.34,22.19,7.69,17.59,0.0071724,-0.0639072,47.8,0.912374024682876,8.36566637822601,2.2163800087130895e-10,0.2518776307912564,81.844800443867,22.368782478051976,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP140,APOS Energy,Multi-c-Si,0,140.0,124.5,1.0230000000000001,1.5,0.682,36.0,8.05,22.39,7.69,17.93,0.0099015,-0.0662744,49.1,0.9463830120909172,8.05000159223616,4.276021711260728e-10,0.197560140597953,999994.1989019854,25.408931398114962,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS140,APOS Energy,Mono-c-Si,0,140.0,125.4,1.0230000000000001,1.5,0.682,36.0,8.51,22.33,7.84,17.76,0.007318599999999999,-0.06431039999999999,47.8,0.9202437480318206,8.536363666780073,2.3879984352969e-10,0.23951353537642522,77.31323391852624,22.915526461131986,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AS145,APOS Energy,Mono-c-Si,0,145.0,130.0,1.0230000000000001,1.5,0.682,36.0,8.63,22.51,7.95,18.03,0.007421800000000001,-0.0648288,47.8,0.9313633827600607,8.6551576566297,2.664298635231347e-10,0.2192230911187084,75.2015752866895,23.876585605858153,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP175,APOS Energy,Multi-c-Si,0,175.0,155.4,1.341,1.341,1.0,48.0,7.9,29.52,7.48,23.31,0.009717,-0.0873792,49.1,1.232777530637489,7.926662446895717,3.158675800301511e-10,0.35618150476017635,999999.8977078898,22.496942072862055,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AP180,APOS Energy,Multi-c-Si,0,180.0,160.0,1.341,1.341,1.0,48.0,7.97,29.72,7.59,23.58,0.009803099999999999,-0.0879712,49.1,1.2492463433713703,7.970002457475274,3.7105800121649905e-10,0.3080546872497566,999999.1836994411,24.062125306064964,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS180,APOS Energy,Mono-c-Si,0,180.0,161.2,1.341,1.341,1.0,48.0,8.34,29.59,7.69,23.45,0.0071724,-0.0852192,47.8,1.216462214604363,8.365716538833906,2.2087748195575468e-10,0.33679452925540093,109.22413046502952,22.334493537642594,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP185,APOS Energy,Multi-c-Si,0,185.0,164.5,1.341,1.341,1.0,48.0,8.05,29.86,7.69,23.9,0.0099015,-0.0883856,49.1,1.261844686579177,8.050002136305777,4.253539714865195e-10,0.2651445343486007,999995.8104003192,25.354792198194055,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS185,APOS Energy,Mono-c-Si,0,185.0,165.8,1.341,1.341,1.0,48.0,8.51,29.78,7.84,23.68,0.007318599999999999,-0.08576639999999999,47.8,1.22711260510798,8.536413009289813,2.380813807574087e-10,0.32022310265743376,103.17259860480064,22.885328099416846,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP190,APOS Energy,Multi-c-Si,0,190.0,168.6,1.5,1.5,1.0,54.0,7.79,32.89,7.33,25.76,0.0095817,-0.09735440000000001,49.1,1.369546525614805,7.792088534156069,2.8896190518191207e-10,0.4380406416748889,1633.8453482535276,21.782746313091835,-0.429,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AS190,APOS Energy,Mono-c-Si,0,190.0,170.4,1.341,1.341,1.0,48.0,8.59,29.92,7.91,23.9,0.0073874,-0.0861696,47.8,1.2363238900750644,8.61606741905633,2.568296484342069e-10,0.3024890745784935,99.67927123304,23.554478920096503,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP195,APOS Energy,Multi-c-Si,0,195.0,173.1,1.5,1.5,1.0,54.0,7.86,33.11,7.43,26.06,0.0096678,-0.0980056,49.1,1.3805955034056165,7.876553797650589,3.026275223672495e-10,0.4155434776390387,999999.9735413775,22.13013153677839,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS195,APOS Energy,Mono-c-Si,0,195.0,174.5,1.5,1.5,1.0,54.0,8.15,32.6,7.48,25.97,0.007009,-0.093888,47.8,1.3472957394341365,8.178434963042063,2.4379923465000006e-10,0.35855681698942676,102.76919494523614,23.570307041628638,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP200,APOS Energy,Multi-c-Si,0,200.0,177.7,1.5,1.5,1.0,54.0,7.94,33.32,7.54,26.37,0.009766200000000001,-0.0986272,49.1,1.3971925209426554,7.940002924559475,3.490124230344922e-10,0.36801292768986643,999991.0038716636,23.479722494410534,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS200,APOS Energy,Mono-c-Si,0,200.0,179.1,1.5,1.5,1.0,54.0,8.28,32.97,7.62,26.18,0.007120799999999999,-0.09495359999999999,47.8,1.358230562866146,8.30704809764301,2.3003555310503488e-10,0.3700748096237467,113.28780629295163,22.818815210834384,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP205,APOS Energy,Multi-c-Si,0,205.0,182.3,1.5,1.5,1.0,54.0,8.01,33.48,7.64,26.68,0.0098523,-0.09910079999999999,49.1,1.4110568234943075,8.01000258224855,3.9734739858944377e-10,0.32211842991494477,999998.5155377822,24.708322840422596,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS205,APOS Energy,Mono-c-Si,0,205.0,183.7,1.5,1.5,1.0,54.0,8.42,33.34,7.77,26.38,0.007241199999999999,-0.0960192,47.8,1.3688573669968942,8.44542980744482,2.1634535263177926e-10,0.3822193772532967,126.55571361840312,22.030337427813723,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP210,APOS Energy,Multi-c-Si,0,210.0,186.3,1.659,1.659,1.0,60.0,7.79,36.55,7.33,28.62,0.0095817,-0.10818799999999999,49.1,1.5217560584375174,7.792065518627015,2.880892072447039e-10,0.4878497997705936,1839.9025780120792,21.752526563646235,-0.429,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AS210,APOS Energy,Mono-c-Si,0,210.0,188.3,1.5,1.5,1.0,54.0,8.51,33.5,7.84,26.63,0.007318599999999999,-0.09648,47.8,1.380166202796101,8.536479116219821,2.371191613776947e-10,0.3614333454517973,116.15939074032028,22.844757289984013,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP215,APOS Energy,Multi-c-Si,0,215.0,190.9,1.659,1.659,1.0,60.0,7.86,36.79,7.43,28.96,0.0096678,-0.10889839999999999,49.1,1.5341372305298493,7.876448991531752,3.03077357673265e-10,0.4611642789156264,999999.9771927146,22.145090101066657,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS215,APOS Energy,Mono-c-Si,0,215.0,192.9,1.5,1.5,1.0,54.0,8.59,33.66,7.91,26.89,0.0073874,-0.09694079999999998,47.8,1.390936631245086,8.616045148312717,2.57149775679753e-10,0.3399265449563009,112.11182952341478,23.567034139905758,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP220,APOS Energy,Multi-c-Si,0,220.0,195.4,1.659,1.659,1.0,60.0,7.9,36.91,7.48,29.13,0.009717,-0.10925359999999999,49.1,1.5409785877264577,7.927129315311094,3.1387517465653943e-10,0.4477641805583706,999999.9774001627,22.43303137758887,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS220,APOS Energy,Mono-c-Si,0,220.0,197.0,1.659,1.659,1.0,60.0,8.28,36.63,7.62,29.08,0.007120799999999999,-0.1054944,47.8,1.5088261336119957,8.307096112950077,2.293706202836641e-10,0.4121265703392198,125.93718726875161,22.789828311169806,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP225,APOS Energy,Multi-c-Si,0,225.0,200.0,1.659,1.659,1.0,60.0,7.97,37.14,7.59,29.48,0.009803099999999999,-0.1099344,49.1,1.5614441686404925,7.970003055847638,3.7279497004249157e-10,0.3831346856880827,999999.3867688704,24.109573841854345,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS225,APOS Energy,Mono-c-Si,0,225.0,201.6,1.659,1.659,1.0,60.0,8.34,36.99,7.69,29.31,0.0071724,-0.10653119999999999,47.8,1.520550371280484,8.36574656382934,2.2042228650546036e-10,0.4217114573196559,136.60362082825898,22.313920436157936,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AP230,APOS Energy,Multi-c-Si,0,230.0,204.6,1.659,1.659,1.0,60.0,8.05,37.32,7.69,29.88,0.0099015,-0.1104672,49.1,1.5773071029020733,8.050002659401459,4.2671206623298236e-10,0.3301265575575475,999996.72929958,25.38753204606699,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +APOS Energy AS230,APOS Energy,Mono-c-Si,0,230.0,206.1,1.659,1.659,1.0,60.0,8.46,37.11,7.82,29.42,0.0072756,-0.1068768,47.8,1.5240144529791952,8.483455569684656,2.1904898893815115e-10,0.4147125869006379,149.57934625042526,22.101384978815435,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AS235,APOS Energy,Mono-c-Si,0,235.0,210.7,1.659,1.659,1.0,60.0,8.55,37.34,7.86,29.76,0.007353,-0.10753920000000002,47.8,1.5423014067671228,8.578106168757651,2.5270389736315254e-10,0.38935786851622667,118.44410505656501,23.443782364237197,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +APOS Energy AS240,APOS Energy,Mono-c-Si,0,240.0,215.4,1.659,1.659,1.0,60.0,8.63,37.52,7.95,30.05,0.007421800000000001,-0.1080576,47.8,1.5523332117603172,8.655179148881993,2.6611349183661787e-10,0.3658011205343431,125.37611603374968,23.86458193996918,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials 1/4 Size Tandem Junction,Applied Materials,Thin Film,0,114.0,104.6,1.4300000000000002,1.3,1.1,106.0,1.3,137.6,1.08,106.0,0.0013520000000000001,-0.5517759999999999,44.1,5.860480321070907,1.327066934806683,7.075590808301451e-11,13.415436547002106,644.3311178003212,-7.261177784852931,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials 1/4 Size Single Junction Version 10,Applied Materials,Thin Film,0,116.0,107.9,1.4300000000000002,1.3,1.1,106.0,1.7,96.2,1.47,77.8,0.00136,-0.31746,44.8,3.6835183449670534,1.717038768175792,6.889278696485883e-12,4.767498132715224,475.66506969899035,-8.20126377087832,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials 1/2-L Size Single Junction Version 10,Applied Materials,Thin Film,0,207.0,192.4,2.8600000000000003,2.2,1.3,216.0,1.45,194.2,1.3,159.8,0.00116,-0.64086,44.8,7.356437953320238,1.457289731261632,4.62080012263065e-12,8.886275990886649,1767.568619950701,-10.05370166785354,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials 1/2-P Size Single Junction Version 10,Applied Materials,Thin Film,0,207.0,192.4,2.8600000000000003,2.6,1.1,106.0,2.9,97.1,2.59,79.9,0.00232,-0.32043,44.8,3.686343292438945,2.915433549585121,9.750034478578288e-12,2.217621020064072,416.69616842878486,-9.651342267640267,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials 1/2-L Size Tandem Junction,Applied Materials,Thin Film,0,229.0,210.1,2.8600000000000003,2.2,1.3,216.0,1.3,280.0,1.08,216.0,0.0013520000000000001,-1.1228000000000002,44.1,11.937781856119058,1.3267073183234717,7.248659968411902e-11,26.954151597286288,1312.0148697603486,-7.077015048036543,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials 1/2-P Size Tandem Junction,Applied Materials,Thin Film,0,229.0,210.1,2.8600000000000003,2.6,1.1,106.0,2.6,137.6,2.16,106.0,0.0027040000000000002,-0.5517759999999999,44.1,5.86048031024492,2.6541338692138092,1.41511813250192e-10,6.7077182167173115,322.16555855026417,-7.261176547071372,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials Full Size Single Junction Version 10,Applied Materials,Thin Film,0,414.0,384.8,5.720000000000001,2.6,2.2,216.0,2.9,194.2,2.59,159.8,0.00232,-0.64086,44.8,7.372687091691701,2.9154335476860016,9.750051959746502e-12,4.435241666539403,833.3923692135377,-9.651331711714265,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +Applied Materials Full Size Tandem Junction,Applied Materials,Thin Film,0,458.0,420.2,5.720000000000001,2.6,2.2,216.0,2.6,280.0,2.16,216.0,0.0027040000000000002,-1.1228000000000002,44.1,11.937782009397425,2.653414637774816,1.4497323078146165e-10,13.477076162875031,656.007438763107,-7.077018025647319,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF23-320W,Aptos Solar Technology LLC,Mono-c-Si,1,320.0,296.1,1.658,,,60.0,10.13,40.18,9.7,32.99,0.0046598,-0.11049500000000001,46.38,1.4973149213862798,10.130002568296987,2.2461809944570618e-11,0.25352241336386566,999995.1390653998,5.2338026205473955,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-320W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,320.0,290.2,1.687368,,,60.0,10.13,39.92,9.69,33.01,0.00694918,-0.12622703999999998,48.5,1.616178400183834,10.130001924791669,1.8985776722740249e-10,0.1899660335864507,999999.4820124713,8.346817575638676,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-320W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,320.0,299.0,1.63,,,60.0,10.13,39.92,9.69,33.01,0.0043559,-0.10658640000000001,44.37,1.4674384754101109,10.130002412138813,1.5528118727785682e-11,0.23811161147751703,999998.7320484531,5.251174709287448,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-BF23-325W,Aptos Solar Technology LLC,Mono-c-Si,1,325.0,300.8,1.658,,,60.0,10.15,40.3,9.82,33.1,0.004669,-0.110825,46.38,1.5087796950032855,10.150002099497822,2.5486869801675923e-11,0.20677899134004707,999707.4276057429,6.298496969232544,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-325W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,325.0,294.8,1.687368,,,60.0,10.43,40.1,9.93,32.71,0.00715498,-0.1267962,48.5,1.6097192896213282,10.43000262637483,1.5830572378100448e-10,0.2517464026198033,999999.6596255436,6.515080459614108,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-325W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,325.0,303.8,1.63,,,60.0,10.43,40.1,9.93,32.71,0.0044849,-0.10706700000000001,44.37,1.4641920534659896,10.431193635511852,1.3292498939862344e-11,0.2926780896806768,2557.424479442638,3.690510871845417,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF23-330W,Aptos Solar Technology LLC,Mono-c-Si,1,330.0,305.6,1.658,,,60.0,10.25,40.39,9.93,33.24,0.0047150000000000004,-0.11107250000000002,46.38,1.5143405343691692,10.250001961936272,2.6752264608081257e-11,0.19134603681417198,999710.1868081596,6.631406101678401,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-330W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,330.0,299.5,1.687368,,,60.0,10.51,40.27,10.02,32.91,0.007209859999999999,-0.12733374,48.5,1.6189752000308448,10.510002514504084,1.6560162612623525e-10,0.23918586024488556,999993.2000934965,6.83771483995845,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-330W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,330.0,308.6,1.63,,,60.0,10.51,40.27,10.02,32.91,0.0045192999999999995,-0.10752090000000002,44.37,1.470880819353742,10.51000416387591,1.3533802473860157e-11,0.28460287451973065,718378.9446036828,3.772649156976001,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF23-335W,Aptos Solar Technology LLC,Mono-c-Si,1,335.0,310.3,1.658,,,60.0,10.34,40.46,10.03,33.4,0.0047564,-0.11126500000000002,46.38,1.5198404067173739,10.340001783263201,2.8383871554705873e-11,0.1724280731681357,999835.3596823497,7.067482938938364,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-335W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,335.0,304.2,1.687368,,,60.0,10.6,40.44,10.11,33.11,0.0072716,-0.12787127999999998,48.5,1.6275112607486355,10.600002439999043,1.7142008607842163e-10,0.23012807060468438,999991.4920755792,7.062533301352397,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-335W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,335.0,313.4,1.63,,,60.0,10.6,40.44,10.11,33.11,0.0045579999999999996,-0.1079748,44.37,1.4784941511361318,10.600004153902342,1.4009223065402097e-11,0.2763610713413967,705236.8329791877,3.9919998454327286,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF23-340W,Aptos Solar Technology LLC,Mono-c-Si,1,340.0,317.3,1.644,,,60.0,10.43,40.6,10.11,33.62,0.0039634,-0.11246200000000002,44.45,1.5178412693958554,10.430001745580784,2.5208686392635928e-11,0.16731003414636264,999723.3796200273,5.304968512367707,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-340W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,340.0,308.9,1.687368,,,60.0,10.69,40.62,10.21,33.31,0.007333339999999999,-0.12844044,48.5,1.637010062490892,10.690002335190956,1.788943161022528e-10,0.21839328777385933,999999.6753854288,7.359121721332958,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF23-340W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,340.0,318.2,1.63,,,60.0,10.69,40.62,10.21,33.31,0.0045967,-0.10845540000000001,44.37,1.4869427132896809,10.690002822313032,1.4622022197448026e-11,0.2640064641215188,999999.7155066212,4.28251807048531,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-BF26-360W,Aptos Solar Technology LLC,Mono-c-Si,1,360.0,332.0,1.76,,,60.0,11.26,40.26,10.72,33.58,0.005067,-0.11796179999999999,47.2,1.52695035544086,11.26143206709167,3.979173377885358e-11,0.18459769205461674,1451.4474860118557,2.5428202678402347,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF26-360W,Aptos Solar Technology LLC,Mono-c-Si,0,360.0,328.3,1.76,,,60.0,11.24,40.6,10.66,33.8,0.0012364,-0.11286800000000002,48.4,1.5297588326994198,11.244497187031143,3.322645598421154e-11,0.19535503055283715,488.2586781783822,7.020335156831882,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF26-365W,Aptos Solar Technology LLC,Mono-c-Si,1,365.0,336.7,1.76,,,60.0,11.28,40.59,10.75,34.0,0.005076,-0.1189287,47.2,1.5421085730484065,11.280870554639083,4.1737261750068676e-11,0.17036383675672215,2207.447660596733,2.921268188659858,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF26-365W,Aptos Solar Technology LLC,Mono-c-Si,0,365.0,333.1,1.76,,,60.0,11.36,40.7,10.75,33.96,0.0012495999999999998,-0.11314600000000002,48.4,1.53698109898777,11.366070029668611,3.554484573457519e-11,0.1853470095164951,346.87508616007545,7.521101039668826,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF26-370W,Aptos Solar Technology LLC,Mono-c-Si,1,370.0,341.5,1.76,,,60.0,11.3,40.91,10.84,34.2,0.005085,-0.11986629999999998,47.2,1.5555011002747634,11.300001803735181,4.2760465660993856e-11,0.15961395630567454,999997.8543873949,3.102436838481405,-0.366,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF26-370W,Aptos Solar Technology LLC,Mono-c-Si,0,370.0,337.8,1.76,,,60.0,11.51,40.8,10.87,34.06,0.0012660999999999998,-0.113424,48.4,1.526952603652229,11.510002378467917,2.8626911627074894e-11,0.18438762495126593,892330.1189362379,5.517750364910998,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-385W,Aptos Solar Technology LLC,Mono-c-Si,1,385.0,358.8,1.93,,,54.0,13.52,36.72,12.65,30.44,0.00492128,-0.0910656,46.93,1.3058689371318561,13.542967419534579,8.089920308786613e-12,0.17251632884843254,101.55345357440883,5.197381991328475,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-390W,Aptos Solar Technology LLC,Mono-c-Si,1,390.0,363.6,1.93,,,54.0,13.61,36.85,12.73,30.64,0.00495404,-0.091388,46.93,1.312638659737849,13.63250657428262,8.521255938927754e-12,0.16367845627546268,98.9783592000542,5.590154924968769,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF23-390W,Aptos Solar Technology LLC,Mono-c-Si,1,390.0,361.0,1.981,,,72.0,10.14,48.18,9.83,39.68,0.0046644,-0.132495,46.38,1.8075171980119689,10.140002353958378,2.6900809186136108e-11,0.2233716431035707,962230.8964170993,6.772326157642555,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-390W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,390.0,353.5,2.012016,,,72.0,10.48,48.18,9.66,40.37,0.00512472,-0.15330876,48.1,1.9805523988175096,10.496323281836789,2.7473115968181385e-10,0.1836579831637112,117.91352596959274,10.982728660930528,-0.4149,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-390W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,390.0,364.4,1.95,,,72.0,10.48,48.18,9.66,40.37,0.0045064,-0.12864060000000002,44.52,1.8139982869523306,10.501883332837041,2.9319886703737135e-11,0.22157789766380556,106.11438362194517,10.665600970926176,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-395W,Aptos Solar Technology LLC,Mono-c-Si,1,395.0,368.4,1.93,,,54.0,13.7,36.98,12.81,30.84,0.0049868,-0.09171039999999998,46.93,1.3040765521231448,13.722805572685473,6.449381551248987e-12,0.15766160406890245,94.71211304900056,3.162425431840026,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-395W,Aptos Solar Technology LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF23-395W,Aptos Solar Technology LLC,Mono-c-Si,1,395.0,365.8,1.981,,,72.0,10.23,48.26,9.92,39.82,0.0047058000000000004,-0.132715,46.38,1.8122007840643877,10.230002255887863,2.781951654320625e-11,0.2120355955343556,961565.6709569648,6.986228725023647,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-395W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,395.0,358.2,2.012016,,,72.0,10.56,48.37,9.74,40.55,0.00516384,-0.15391333999999998,48.1,1.988227067732315,10.575930274975962,2.765674626929874e-10,0.18065530335681138,119.75437082247376,10.972109033691147,-0.4149,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-395W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,395.0,369.1,1.95,,,72.0,10.56,48.37,9.74,40.55,0.0045408,-0.1291479,44.52,1.8210374093223074,10.581441774202847,2.951548623613439e-11,0.21841563060895752,107.5689467439508,10.654512002932163,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-400W,Aptos Solar Technology LLC,Mono-c-Si,1,400.0,373.2,1.93,,,54.0,13.79,37.07,12.9,31.01,0.00501956,-0.0919336,46.93,1.3243294691228409,13.810662308014873,9.365098184682618e-12,0.14592235016731542,97.38841917730565,6.294985256745999,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-400W,Aptos Solar Technology LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-400W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,400.0,377.0,1.94,,,54.0,13.39,37.2,12.74,31.4,0.005623800000000001,-0.088164,43.4,1.3409552437993895,13.394262402841294,1.1908487156673971e-11,0.12360711502513322,388.3020473251509,13.568988467976041,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-400W-USAptos1a,Aptos Solar Technology LLC,Mono-c-Si,0,400.0,371.5,1.94,,,54.0,13.7,37.1,12.95,30.9,0.006849999999999999,-0.10796099999999999,46.4,1.389877667180983,13.708847279184651,3.460818900481792e-11,0.1468137968545514,227.340971242788,0.45348084470630884,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-400W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,400.0,377.0,1.94,,,54.0,13.39,37.2,12.74,31.4,0.005623800000000001,-0.088164,43.4,1.3409552437993895,13.394262402841294,1.1908487156673971e-11,0.12360711502513322,388.3020473251509,13.568988467976041,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF23-400W,Aptos Solar Technology LLC,Mono-c-Si,1,400.0,370.5,1.981,,,72.0,10.32,48.35,10.0,40.0,0.0047472,-0.1329625,46.38,1.8170768078232598,10.320002103549692,2.8686562924801072e-11,0.20381322927048903,999935.9701402877,7.1761488525547685,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-400W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,400.0,362.9,2.012016,,,72.0,10.64,48.55,9.81,40.77,0.00520296,-0.1544861,48.1,1.9979961294665916,10.655530188230907,2.866414766642244e-10,0.1716204700444781,117.58014934954356,11.227200673899867,-0.4149,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-400W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,400.0,373.9,1.95,,,72.0,10.64,48.55,9.81,40.77,0.0045752,-0.1296285,44.52,1.8298075916043999,10.661053996285682,3.059339222846159e-11,0.20938480169216456,105.81621976042658,10.910559949223902,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-405W,Aptos Solar Technology LLC,Mono-c-Si,1,405.0,378.0,1.93,,,54.0,13.87,37.23,12.98,31.21,0.00504868,-0.09233039999999999,46.93,1.3311810673366349,13.889706380776266,9.649688864278785e-12,0.1399040369790604,98.46907043419202,6.503665544100626,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-405W,Aptos Solar Technology LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-405W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.44,37.3,12.84,31.6,0.0056448,-0.088401,43.4,1.3206256962162575,13.440003432364781,7.279506120664736e-12,0.11770687271836987,460903.2638580368,9.032475101217877,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-405W-USAptos1a,Aptos Solar Technology LLC,Mono-c-Si,0,405.0,376.3,1.94,,,54.0,13.77,37.3,13.03,31.1,0.006885,-0.10854299999999999,46.4,1.3974193698670139,13.777833135332704,3.485751857208748e-11,0.14397077610806178,253.08864591372,0.46660543576595276,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-405W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.44,37.3,12.84,31.6,0.0056448,-0.088401,43.4,1.3206256962162575,13.440003432364781,7.279506120664736e-12,0.11770687271836987,460903.2638580368,9.032475101217877,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF23-405W,Aptos Solar Technology LLC,Mono-c-Si,1,405.0,375.3,1.981,,,72.0,10.42,48.45,10.08,40.18,0.0047932,-0.1332375,46.38,1.8213988955334646,10.420002104875977,2.920413510346616e-11,0.20198300112671758,999928.8740275401,7.24756968963717,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-405W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,405.0,367.6,2.012016,,,72.0,10.71,48.73,9.89,40.95,0.005237190000000001,-0.15505885999999997,48.1,2.004443974323833,10.724636258621304,2.8570367544782565e-10,0.16814596860296788,123.03987122967811,11.13323888741621,-0.4149,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-405W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,405.0,378.7,1.95,,,72.0,10.71,48.73,9.89,40.95,0.0046053000000000005,-0.1301091,44.52,1.835783534055856,10.729995388396565,3.049157202025956e-11,0.2057151716588234,110.18588149261802,10.815460227538239,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-410W,Aptos Solar Technology LLC,Mono-c-Si,1,410.0,382.8,1.93,,,54.0,13.95,37.32,13.04,31.45,0.0050777999999999995,-0.09255360000000001,46.93,1.338581206333317,13.968863507946907,1.0572372673100285e-11,0.1249391643644218,92.39539914054541,7.256759079870228,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-410W,Aptos Solar Technology LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.59,37.7,12.88,31.8,0.0057078,-0.08934900000000001,43.4,1.3609863004663645,13.597242859906375,1.2534716190713868e-11,0.12505319177147073,234.64113698931806,13.925662256675508,-0.328,N,2025.7.3,6/23/2025,4.0,bootstrapping +Aptos Solar Technology LLC DNA-108-MF10-410W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.59,37.7,12.88,31.8,0.0057078,-0.08934900000000001,43.4,1.3609863004663645,13.597242859906375,1.2534716190713868e-11,0.12505319177147073,234.64113698931806,13.925662256675508,-0.328,N,2025.7.3,6/23/2025,4.0,bootstrapping +Aptos Solar Technology LLC DNA-144-BF23-410W,Aptos Solar Technology LLC,Mono-c-Si,1,410.0,382.8,1.95,,,72.0,10.51,48.56,10.16,40.38,0.0039938,-0.13451120000000003,44.45,1.8165742789764594,10.510002157568573,2.583445334880758e-11,0.19680445371983707,958702.2857221005,5.448671170857095,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-410W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,410.0,372.3,2.012016,,,72.0,10.79,48.91,9.97,41.12,0.005276309999999999,-0.15563162,48.1,2.011675885377106,10.804288301232859,2.8743762886996937e-10,0.1654861338276354,124.96905029014054,11.11856124791449,-0.4149,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF23-410W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,410.0,383.5,1.95,,,72.0,10.79,48.91,9.97,41.12,0.004639699999999999,-0.1305897,44.52,1.8424194321997094,10.809600542226658,3.067617845682698e-11,0.2028924230087667,111.69125969649802,10.8004009485304,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BF10-415W,Aptos Solar Technology LLC,Mono-c-Si,0,415.0,391.2,1.95,,,54.0,14.02,37.5,13.13,31.6,0.005608,-0.10724999999999998,43.1,1.3854072736159415,14.035647494177883,2.4027158642767278e-11,0.11805146185858889,105.7729424155366,-0.7617279535236223,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-415W,Aptos Solar Technology LLC,Mono-c-Si,0,415.0,389.1,1.94,,,54.0,13.91,37.7,13.18,31.5,0.0082069,-0.09575800000000001,45.3,1.3550564552265978,13.9186133537797,1.1371854954420555e-11,0.14812439940780317,239.21116654268192,4.976155115822077,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,415.0,391.5,1.94,,,54.0,13.72,37.8,13.0,31.9,0.005762400000000001,-0.089586,43.4,1.3650757381145562,13.727437068693108,1.2774069970440368e-11,0.12280310153304241,226.5487424956598,14.014314461146293,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a,Aptos Solar Technology LLC,Mono-c-Si,0,415.0,385.9,1.94,,,54.0,13.91,37.7,13.18,31.5,0.006955,-0.10970700000000001,46.4,1.4035918673767436,13.91000360631191,3.0083130062852387e-11,0.13978929004886906,539198.4040500257,-0.843768229924351,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,415.0,391.5,1.94,,,54.0,13.72,37.8,13.0,31.9,0.005762400000000001,-0.089586,43.4,1.3650757381145562,13.727437068693108,1.2774069970440368e-11,0.12280310153304241,226.5487424956598,14.014314461146293,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF23-415W,Aptos Solar Technology LLC,Mono-c-Si,1,415.0,387.6,1.95,,,72.0,10.61,48.64,10.25,40.5,0.0040318,-0.1347328,44.45,1.820092753883523,10.610002143409845,2.6282431236087076e-11,0.19332734024384224,957005.0950688091,5.514470894218182,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-420W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,420.0,398.5,1.94,,,54.0,13.93,37.6,13.16,31.9,0.0066864,-0.081968,43.2,1.3219546286347965,13.940188403657771,6.082335956716806e-12,0.11258882455512155,153.93602388634983,16.518076486666025,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-420W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,420.0,396.3,1.94,,,54.0,13.8,38.0,13.09,32.1,0.005796000000000001,-0.09006,43.4,1.3722461803247208,13.806577211980795,1.2850210950858145e-11,0.120107639421166,252.00425901596364,14.010513957949227,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-420W-USAptos1a,Aptos Solar Technology LLC,Mono-c-Si,0,420.0,390.7,1.94,,,54.0,13.98,37.9,13.25,31.7,0.0069900000000000006,-0.110289,46.4,1.4210968572483302,13.986299439342698,3.625252646966299e-11,0.13553466183448148,300.7846357411462,0.6575636637419493,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MF10-420W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,420.0,396.3,1.94,,,54.0,13.8,38.0,13.09,32.1,0.005796000000000001,-0.09006,43.4,1.3722461803247208,13.806577211980795,1.2850210950858145e-11,0.120107639421166,252.00425901596364,14.010513957949227,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MFN10-420W,Aptos Solar Technology LLC,Mono-c-Si,0,420.0,399.2,1.94,,,54.0,13.4,38.5,12.76,32.9,0.00603,-0.088935,43.1,1.3410778942457475,13.404264085872404,4.523649707879449e-12,0.10173630068908206,319.70895361895566,7.617653475486354,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-425W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,425.0,403.3,1.94,,,54.0,13.64,38.6,13.01,32.7,0.006547200000000001,-0.084148,43.2,1.3503992150704347,13.64349291384125,5.229102925801398e-12,0.12307017306280177,480.5950688898666,15.227365160993216,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MFN10-425W,Aptos Solar Technology LLC,Mono-c-Si,0,425.0,404.0,1.94,,,54.0,13.48,38.6,12.85,33.1,0.006066,-0.08916600000000001,43.1,1.3271708847542678,13.483832433079446,3.1251106345292993e-12,0.09483187216135423,333.55667585704515,4.328032756307125,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-430W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,430.0,408.2,1.94,,,54.0,13.72,38.8,13.09,32.9,0.006585600000000001,-0.08458399999999999,43.2,1.3578029285697846,13.723285017921771,5.306324901973702e-12,0.12036068103778522,502.6909929613911,15.309895073444766,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MFN10-430W,Aptos Solar Technology LLC,Mono-c-Si,0,430.0,408.9,1.94,,,54.0,13.57,38.8,12.95,33.2,0.006106500000000001,-0.089628,43.1,1.3510192910852932,13.573007903216716,4.542773368730125e-12,0.09765663635137578,440.57287231461515,7.533142339461228,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF26-430W,Aptos Solar Technology LLC,Mono-c-Si,1,430.0,396.5,2.1,,,72.0,10.85,49.17,10.36,41.51,0.0048825,-0.1440681,47.2,1.8738942833255108,10.850022237046138,4.362640186553402e-11,0.17894427075456718,87311.59375038836,3.6088097224023765,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF26-430W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,430.0,394.8,2.1,,,72.0,11.19,49.5,10.6,40.6,0.0074973,-0.14948999999999998,47.4,1.9347618178173802,11.190008842705762,8.661610083067529e-11,0.2884621127764893,365049.70328300906,5.677366322402263,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF26-430W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,430.0,398.7,2.1,,,72.0,11.19,49.5,10.6,40.6,0.0074973,-0.14948999999999998,44.9,1.9347618178173802,11.190008842705762,8.661610083067529e-11,0.2884621127764893,365049.70328300906,5.677366322402263,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-435W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,435.0,413.0,1.94,,,54.0,13.8,39.0,13.17,33.0,0.0066240000000000005,-0.08502,43.2,1.3633225617073628,13.803149723426,5.1769472559272165e-12,0.12629116182464883,553.3242876453895,15.018385871931336,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MFN10-435W,Aptos Solar Technology LLC,Mono-c-Si,0,435.0,413.7,1.94,,,54.0,13.65,38.9,13.05,33.3,0.0061425,-0.08985900000000001,43.1,1.3536623571350335,13.652007423497547,4.498256248735694e-12,0.0962757111291419,654.6518293296084,7.385132311760694,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-435W,Aptos Solar Technology LLC,Mono-c-Si,1,435.0,402.6,2.14,,,60.0,13.66,41.02,12.91,33.76,0.00618798,-0.11231276000000001,46.79,1.5278901232515902,13.66996049091296,2.959714401253901e-11,0.19886504217960363,272.72717161247715,5.547034442891117,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-435W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,1,435.0,410.3,2.14,,,60.0,13.32,40.99,12.73,34.18,0.00551448,-0.09513779000000001,43.4,1.440731473613972,13.320005255645448,5.8676588900787875e-12,0.17927951209000675,454371.2937852086,9.487428744305664,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-435W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,1,435.0,410.3,2.14,,,60.0,13.32,41.0,12.73,34.2,0.005461200000000001,-0.09512000000000001,43.4,1.440331951529444,13.320005226650924,5.78125704545893e-12,0.17845300612579398,454785.5102110979,9.407256491885498,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-435W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,435.0,409.9,2.14,,,60.0,13.32,40.99,12.73,34.18,0.005621040000000001,-0.09698234000000001,43.3,1.4537539932539318,13.320043640844935,7.57055839024285e-12,0.17698856312773212,54020.249209075824,9.64697117007889,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-435W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,435.0,409.9,2.14,,,60.0,13.32,40.99,12.73,34.18,0.005621040000000001,-0.09698234000000001,43.3,1.4537539932539318,13.320043640844935,7.57055839024285e-12,0.17698856312773212,54020.249209075824,9.64697117007889,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF26-435W,Aptos Solar Technology LLC,Mono-c-Si,1,435.0,401.3,2.1,,,72.0,10.92,49.38,10.42,41.75,0.004914,-0.1446834,47.2,1.883982258967295,10.920412724766567,4.516037515462111e-11,0.17151376078154257,4537.965172273935,3.8474969344428795,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF26-435W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,435.0,399.5,2.1,,,72.0,11.26,49.7,10.67,40.8,0.007544200000000001,-0.150094,47.4,1.9498805152993317,11.263238714278703,9.551895014834608e-11,0.28271663484182086,982.917732445926,6.476542394837407,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF26-435W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,435.0,403.5,2.1,,,72.0,11.26,49.7,10.67,40.8,0.007544200000000001,-0.150094,44.9,1.9498805152993317,11.263238714278703,9.551895014834608e-11,0.28271663484182086,982.917732445926,6.476542394837407,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-440W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,440.0,417.9,1.94,,,54.0,13.88,39.2,13.25,33.2,0.006662400000000001,-0.085456,43.2,1.3707272480664654,13.882948009914186,5.253321558160884e-12,0.12359434218837782,581.9144199009086,15.101321543510565,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MFN10-440W,Aptos Solar Technology LLC,Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.73,39.0,13.15,33.5,0.0061785,-0.09009,43.1,1.3417145762807468,13.731305334316822,3.255621826661604e-12,0.08922016364770087,938.4514263166426,4.500310452743691,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-440W,Aptos Solar Technology LLC,Mono-c-Si,1,440.0,407.4,2.14,,,60.0,13.71,41.11,13.01,33.89,0.00621063,-0.11255918,46.79,1.5295634660032462,13.715410167170413,2.897599348701896e-11,0.1937344001185238,490.9457709284508,5.318195824614922,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,1,440.0,415.1,2.14,,,60.0,13.37,41.18,12.82,34.33,0.005535179999999999,-0.09557878,43.4,1.4214103404587233,13.37000455347189,3.5001412044661726e-12,0.1845143564426931,541776.8823745312,4.896327035735192,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-440W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,1,440.0,415.1,2.14,,,60.0,13.37,41.2,12.82,34.3,0.0054817,-0.09558400000000002,43.4,1.4585869550131858,13.405382839673337,7.243623453098962e-12,0.1818899886057235,77367.31369431863,11.39161235489867,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-440W,Aptos Solar Technology LLC,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,440.0,414.8,2.14,,,60.0,13.37,41.18,12.82,34.33,0.0056421399999999995,-0.09743188,43.3,1.4335079004901279,13.370004500748088,4.469583640946862e-12,0.18238956675375423,541812.0071415033,4.972670763848432,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,440.0,414.8,2.14,,,60.0,13.37,41.18,12.82,34.33,0.0056421399999999995,-0.09743188,43.3,1.4335079004901279,13.370004500748088,4.469583640946862e-12,0.18238956675375423,541812.0071415033,4.972670763848432,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF26-440W,Aptos Solar Technology LLC,Mono-c-Si,1,440.0,406.0,2.1,,,72.0,11.0,49.57,10.48,41.99,0.0049499999999999995,-0.1452401,47.2,1.8945703491188624,11.001212278635982,4.7546652144848404e-11,0.16191198692213768,1469.1605636025645,4.225644031566627,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF26-440W {Blk},Aptos Solar Technology LLC,Mono-c-Si,0,440.0,404.2,2.1,,,72.0,11.33,49.9,10.74,41.0,0.0075911,-0.150698,47.4,1.9583168009806837,11.332974923606098,9.68833686996204e-11,0.2782467487559686,1059.7031929688155,6.544338007914559,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF26-440W {Wht},Aptos Solar Technology LLC,Mono-c-Si,0,440.0,408.3,2.1,,,72.0,11.33,49.9,10.74,41.0,0.0075911,-0.150698,44.9,1.9583168009806837,11.332974923606098,9.68833686996204e-11,0.2782467487559686,1059.7031929688155,6.544338007914559,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-445W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,445.0,422.8,1.94,,,54.0,13.96,39.4,13.33,33.4,0.0067008,-0.08589200000000001,43.2,1.3781314663238542,13.962752907620231,5.3300855693977556e-12,0.12093031007677171,613.2378457989307,15.183321972898487,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-MFN10-445W,Aptos Solar Technology LLC,Mono-c-Si,0,445.0,423.5,1.94,,,54.0,13.81,39.2,13.25,33.6,0.0062144999999999995,-0.09055200000000001,43.1,1.3627289026210065,13.810089442003575,4.438926131390693e-12,0.09258148648876004,14295.124463295771,7.147643037168908,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-445W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,1,445.0,419.9,2.14,,,60.0,13.42,41.27,12.92,34.46,0.005555880000000001,-0.09578767000000002,43.4,1.4274173320021486,13.420004382828289,3.7262583247605245e-12,0.1787962984309436,547467.3163535603,5.407337715585005,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-445W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,1,445.0,419.9,2.14,,,60.0,13.42,41.3,12.92,34.5,0.0055022000000000005,-0.095816,43.4,1.4278200273714927,13.420004361338627,3.678657360966264e-12,0.17777240113200118,547014.234342546,5.346988916610413,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-445W,Aptos Solar Technology LLC,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-445W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,445.0,419.6,2.14,,,60.0,13.42,41.27,12.92,34.46,0.005663240000000001,-0.09764482000000002,43.3,1.43966837851643,13.42000433024981,4.765669762663184e-12,0.17666384261392645,547506.4499356266,5.4959249297383845,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-445W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,445.0,419.6,2.14,,,60.0,13.42,41.27,12.92,34.46,0.005663240000000001,-0.09764482000000002,43.3,1.43966837851643,13.42000433024981,4.765669762663184e-12,0.17666384261392645,547506.4499356266,5.4959249297383845,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-450W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,450.0,427.6,1.94,,,54.0,14.04,39.5,13.41,33.6,0.0067392,-0.08611,43.2,1.3836300795172076,14.042528044640452,5.586976761051368e-12,0.1108311496923121,615.5228930972936,15.576093744091791,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-450W,Aptos Solar Technology LLC,Mono-c-Si,1,450.0,416.9,2.14,,,60.0,13.86,41.3,13.2,34.15,0.00627858,-0.11307939999999998,46.79,1.5363597374121933,13.861627834044949,2.9268531919700025e-11,0.1836171827636619,1563.386856134844,5.2967569032789115,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-450W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,1,450.0,424.7,2.14,,,60.0,13.47,41.46,13.01,34.62,0.00557658,-0.09622866000000001,43.4,1.4369426713609366,13.470004338317777,3.9691630542779755e-12,0.17812461514846456,553059.5390738138,5.925366324464752,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-450W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,1,450.0,424.8,2.14,,,60.0,13.47,41.5,13.01,34.6,0.005522700000000001,-0.09628000000000002,43.4,1.4387574504860754,13.470004439901148,4.003412764398867e-12,0.18271004325047324,554317.3728641889,6.052147639988428,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-450W,Aptos Solar Technology LLC,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-450W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,450.0,424.4,2.14,,,60.0,13.47,41.46,13.01,34.62,0.00568434,-0.09809436,43.3,1.4493734110289986,13.470004285776493,5.083581956071468e-12,0.1759808229405341,553102.408986631,6.025318015073531,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-450W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,450.0,424.4,2.14,,,60.0,13.47,41.46,13.01,34.62,0.00568434,-0.09809436,43.3,1.4493734110289986,13.470004285776493,5.083581956071468e-12,0.1759808229405341,553102.408986631,6.025318015073531,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-455W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,455.0,432.5,1.94,,,54.0,14.12,39.7,13.49,33.8,0.0067776,-0.086546,43.2,1.3910322522036418,14.122351687873316,5.666036758043289e-12,0.10827621674193878,650.111865416878,15.65468409447047,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-455W,Aptos Solar Technology LLC,Mono-c-Si,1,455.0,421.7,2.14,,,60.0,13.92,41.51,13.27,34.34,0.00630576,-0.11365437999999999,46.79,1.5438351790636038,13.920635804687537,2.9255309929775027e-11,0.18237458130757148,3992.8196590586194,5.252091980533677,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,1,455.0,429.6,2.14,,,60.0,13.54,41.65,13.09,34.78,0.00560556,-0.09666965,43.4,1.4434369876474362,13.540004356009623,3.9825544614397875e-12,0.17785979751195147,552852.5740278141,5.909513521052539,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-455W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,1,455.0,429.6,2.14,,,60.0,13.54,41.7,13.09,34.8,0.0055514,-0.09674400000000001,43.4,1.419674894880691,13.540004931113094,2.372019323745099e-12,0.184277338206972,505995.47606032377,1.5143081779863306,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-455W,Aptos Solar Technology LLC,Mono-c-Si,0,455.0,426.7,2.16,,,60.0,13.93,41.5,13.06,34.9,0.0050148,-0.10707000000000001,43.1,1.5635106109031605,13.94410670876233,4.0454819371610215e-11,0.13221210255288138,130.55593850911123,14.910200054114512,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-455W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,455.0,429.2,2.14,,,60.0,13.54,41.65,13.09,34.78,0.00571388,-0.0985439,43.3,1.4559174033567936,13.540004303310294,5.100160722650689e-12,0.17572144673488405,552895.2965115889,6.008517926500055,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-455W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,455.0,429.2,2.14,,,60.0,13.54,41.65,13.09,34.78,0.00571388,-0.0985439,43.3,1.4559174033567936,13.540004303310294,5.100160722650689e-12,0.17572144673488405,552895.2965115889,6.008517926500055,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-108-BFN10-460W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,460.0,437.3,1.94,,,54.0,14.2,39.9,13.57,33.9,0.006815999999999999,-0.086982,43.2,1.3965591117015173,14.20220859701825,5.530965025176034e-12,0.11409844849968558,733.5869623021197,15.369378133225954,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-460W,Aptos Solar Technology LLC,Mono-c-Si,0,460.0,433.6,2.16,,,60.0,14.01,41.5,13.45,34.2,0.0056040000000000005,-0.11869,43.1,1.5054311267052356,14.010005184195084,1.4938374210386468e-11,0.19767605274718605,534216.730598317,-4.593168454277231,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BF10-460W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,1,460.0,434.4,2.14,,,60.0,13.63,41.78,13.19,34.89,0.00564282,-0.09697138,43.4,1.4891788650762958,13.630001848278294,8.913451315245978e-12,0.13473516054297466,993485.5369011568,13.087565660983369,-0.3222,N,2025.7.3,6/23/2025,2.0,bootstrapping +Aptos Solar Technology LLC DNA-120-BF10-460W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,1,460.0,434.4,2.14,,,60.0,13.63,41.8,13.19,34.9,0.0055883,-0.096976,43.4,1.4482272761739188,13.630004384552208,3.9765559177313695e-12,0.1777655545534211,552611.5108201907,5.890160497462836,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-460W,Aptos Solar Technology LLC,Mono-c-Si,0,460.0,431.5,2.16,,,60.0,14.0,41.7,13.13,35.1,0.00504,-0.10758600000000001,43.1,1.5715129523116762,14.013677901555967,4.099292579073564e-11,0.12943580298206495,132.48386350916914,14.98508454982021,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-460W-USAptos1,Aptos Solar Technology LLC,Mono-c-Si,0,460.0,434.1,2.14,,,60.0,13.63,41.78,13.19,34.89,0.00575186,-0.09885148,43.3,1.46035365910913,13.630004315429384,5.1232085906789225e-12,0.17494641971327193,552559.467045436,5.990074998572586,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-460W-USAptos2,Aptos Solar Technology LLC,Mono-c-Si,0,460.0,434.1,2.14,,,60.0,13.63,41.78,13.19,34.89,0.00575186,-0.09885148,43.3,1.46035365910913,13.630004315429384,5.1232085906789225e-12,0.17494641971327193,552559.467045436,5.990074998572586,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-MF10-465W,Aptos Solar Technology LLC,Mono-c-Si,0,465.0,436.4,2.16,,,60.0,14.07,41.9,13.19,35.3,0.005065200000000001,-0.108102,43.1,1.5801134620319335,14.083794219712548,4.1915435300720746e-11,0.1265994563829068,129.13049086883038,15.14785266372594,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-120-BFN10-470W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,470.0,445.8,2.16,,,60.0,14.15,42.38,13.41,35.05,0.005843950000000001,-0.10162724000000001,43.5,1.4634564713848486,14.1614254330024,3.7089083833515564e-12,0.20314230712567533,251.58465777688443,1.5631352249891572,-0.2985,N,2025.7.3,6/23/2025,4.0,bootstrapping +Aptos Solar Technology LLC DNA-120-BFN10-475W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,475.0,450.6,2.16,,,60.0,14.23,42.49,13.49,35.21,0.005876990000000001,-0.10189102000000001,43.5,1.468411069235592,14.240960348169565,3.8165707648234665e-12,0.19669802056994004,255.37627044204936,1.7553510015729064,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BFN10-480W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,480.0,455.5,2.16,,,60.0,14.31,42.61,13.57,35.38,0.005910030000000001,-0.10217878,43.5,1.4737436498804601,14.320501587628446,3.9290832295149355e-12,0.190233707101102,259.2224160031431,1.9518438972480274,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BF10-480W,Aptos Solar Technology LLC,Mono-c-Si,1,480.0,451.9,2.37,,,66.0,13.59,45.0,12.71,37.8,0.005436,-0.12869999999999998,43.1,1.6609002173864342,13.60719378139063,2.266532054661044e-11,0.15682016642089375,123.95098091071156,-0.975809117800945,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-120-BFN10-485W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,485.0,460.3,2.16,,,60.0,14.41,42.72,13.64,35.55,0.00595133,-0.10244256000000002,43.5,1.480296686417645,14.42235944769275,4.165040426961438e-12,0.18280502091963347,213.13414816369738,2.393848518032498,-0.2985,N,2025.7.3,6/23/2025,4.0,bootstrapping +Aptos Solar Technology LLC DNA-132-BF10-485W,Aptos Solar Technology LLC,Mono-c-Si,1,485.0,456.7,2.37,,,66.0,13.67,45.1,12.79,37.9,0.005468000000000001,-0.128986,43.1,1.6646156271831842,13.686845974197862,2.2817835352104222e-11,0.15485720239519746,125.66194980436288,-0.970570025878128,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BF10-490W,Aptos Solar Technology LLC,Mono-c-Si,1,490.0,461.5,2.37,,,66.0,13.74,45.3,12.87,38.1,0.005496,-0.12955799999999998,43.1,1.6717740789318505,13.755810085155884,2.288036199868068e-11,0.1520298025891737,132.1238612091068,-0.9938353569862968,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BF10-495W,Aptos Solar Technology LLC,Mono-c-Si,1,495.0,466.3,2.37,,,66.0,13.82,45.4,12.95,38.2,0.005528000000000001,-0.129844,43.1,1.6754954730872011,13.83547933816123,2.30348207276623e-11,0.15011905998937428,134.026752065609,-0.9878660365828106,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BF10-500W,Aptos Solar Technology LLC,Mono-c-Si,1,500.0,471.2,2.37,,,66.0,13.9,45.6,13.03,38.4,0.005560000000000001,-0.130416,43.1,1.6832682103860963,13.915028183823084,2.3323548949670732e-11,0.14716247163618795,136.11480860664307,-0.9354986545219098,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BFN10-515W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,515.0,488.4,2.37,,,66.0,14.21,46.28,13.45,38.27,0.005868730000000001,-0.11097944000000001,43.5,1.5989115506395388,14.222982401197395,3.77223988520765e-12,0.22135777616062702,242.2890696820029,1.6753158919632851,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BFN10-520W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,520.0,493.3,2.37,,,66.0,14.27,46.44,13.54,38.39,0.00589351,-0.11136312,43.5,1.6024527110592204,14.280109338813814,3.66523758767838e-12,0.22223043072438947,313.6929439127191,1.387490865096928,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BFN10-525W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,525.0,498.1,2.37,,,66.0,14.35,46.57,13.65,38.46,0.00592655,-0.11167486,43.5,1.6044375083638394,14.357136180864245,3.533595420093496e-12,0.22473281601912679,451.91062020880645,1.023199741141383,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-132-BFN10-530W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,530.0,503.0,2.37,,,66.0,14.41,46.72,13.73,38.58,0.00595133,-0.11203456,43.5,1.6083535081134324,14.415088739714657,3.4758970551003852e-12,0.22482883075264232,636.657335054756,0.8434267010583125,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-530W,Aptos Solar Technology LLC,Mono-c-Si,1,530.0,499.1,2.58,,,72.0,13.71,49.2,12.82,41.4,0.005484,-0.140712,43.1,1.8177168054163746,13.726885700899235,2.347840466886919e-11,0.16348162284110615,132.73556544102203,-0.7620307730197329,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-MF10-530W,Aptos Solar Technology LLC,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-535W,Aptos Solar Technology LLC,Mono-c-Si,1,535.0,503.9,2.58,,,72.0,13.78,49.4,12.9,41.5,0.005512,-0.141284,43.1,1.822514816026605,13.796665255905195,2.2741037749837433e-11,0.1695403063963445,140.1877921182044,-1.0642107024438168,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-535W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,535.0,504.0,2.57,,,72.0,13.78,49.4,12.9,41.5,0.0049608,-0.13683800000000002,43.2,1.8071668173209074,13.797193513399424,1.8058151585241188e-11,0.17221405352979038,138.0235446284227,0.33281632904610203,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF10-535W,Aptos Solar Technology LLC,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-540W,Aptos Solar Technology LLC,Mono-c-Si,1,540.0,508.8,2.58,,,72.0,13.85,49.5,12.97,41.7,0.005540000000000001,-0.14156999999999997,43.1,1.8285216186657303,13.865594529876685,2.3658970186262416e-11,0.15879487076002038,141.0307965004113,-0.7876494396720093,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-540W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,540.0,508.8,2.57,,,72.0,13.85,49.5,12.97,41.7,0.004986,-0.13711500000000001,43.2,1.813091333563237,13.86610716871159,1.8783591630388587e-11,0.16147354042417808,138.84554015809388,0.6120094531351281,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-MF10-540W,Aptos Solar Technology LLC,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-545W,Aptos Solar Technology LLC,Mono-c-Si,1,545.0,513.6,2.58,,,72.0,13.92,49.7,13.04,41.8,0.005568,-0.142142,43.1,1.8340400207104455,13.935940720497232,2.314408745731457e-11,0.16471144347818584,143.83184898116463,-1.0067463365185205,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-545W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,545.0,513.7,2.57,,,72.0,13.92,49.7,13.04,41.8,0.0050111999999999995,-0.137669,43.2,1.8185877664525838,13.936459824231562,1.837726960085145e-11,0.16737621586893997,141.54932026511332,0.3906677437283002,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-550W,Aptos Solar Technology LLC,Mono-c-Si,1,550.0,518.4,2.58,,,72.0,13.99,49.8,13.11,42.0,0.005596,-0.142428,43.1,1.8400454932892913,14.004900476948619,2.4070751679311814e-11,0.15410834765845804,144.69173037021588,-0.7321354881926299,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-550W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,550.0,518.5,2.57,,,72.0,13.99,49.8,13.11,42.0,0.0050364,-0.137946,43.2,1.824511061292898,14.00540395111646,1.9109600099699812e-11,0.15677801511280334,142.38713318551947,0.6679011759608745,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-555W,Aptos Solar Technology LLC,Mono-c-Si,1,555.0,523.3,2.58,,,72.0,14.02,50.0,13.18,42.1,0.005608,-0.143,43.1,1.842935298986658,14.033061991031586,2.266780253735756e-11,0.16080489272716508,172.598848032139,-1.2445382027776486,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BF10-555W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,555.0,523.3,2.57,,,72.0,14.02,50.0,13.18,42.1,0.005047199999999999,-0.1385,43.2,1.8274322221389896,14.033534243968907,1.8000645872452027e-11,0.16345004417174258,169.31641192156906,0.1496490148557414,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-565W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,565.0,535.9,2.58,,,72.0,14.23,50.6,13.48,41.92,0.005876990000000001,-0.12133880000000001,43.5,1.7490546786298025,14.241842495055606,3.83679221262941e-12,0.23511822348788758,282.519208265435,1.8030156128449524,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-570W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,570.0,540.8,2.58,,,72.0,14.31,50.74,13.55,42.07,0.005910030000000001,-0.12167452000000002,43.5,1.754897312446666,14.322320127545886,3.9204628508612445e-12,0.23158690587369044,268.99142177216567,1.9395152729422247,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-575W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,575.0,545.6,2.58,,,72.0,14.39,50.88,13.62,42.22,0.005943070000000001,-0.12201024000000002,43.5,1.7607394540777483,14.402782185996228,4.00538473168953e-12,0.22809221378738206,256.7829140045023,2.0752034321156914,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-580W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,580.0,550.5,2.58,,,72.0,14.47,51.02,13.69,42.37,0.0059761100000000015,-0.12234596,43.5,1.76658111064056,14.483228817230769,4.091566735658218e-12,0.22463358112837256,245.70963647685156,2.210088479807043,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-585W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,585.0,555.6,2.58,,,72.0,13.85,52.2,13.23,44.2,0.006648000000000001,-0.11379600000000001,43.2,1.8245881198272904,13.852463521998361,5.187432048815055e-12,0.16587736019399885,932.5678665246049,14.998739184743348,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-590W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,590.0,560.5,2.58,,,72.0,13.9,52.4,13.29,44.4,0.006672000000000001,-0.114232,43.2,1.8314129212496657,13.901798173763762,5.1979354454374835e-12,0.16338941738961976,1263.0108296955545,14.979240298128214,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-595W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,595.0,565.3,2.58,,,72.0,13.95,52.5,13.35,44.6,0.006696,-0.11445000000000001,43.2,1.836331152857211,13.95119764265961,5.338068359614954e-12,0.1534234268381217,1787.0579474489339,15.19357296163031,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-600W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,600.0,570.2,2.58,,,72.0,14.0,52.7,13.41,44.8,0.006720000000000001,-0.114886,43.2,1.843154397752599,14.00060010737247,5.348226735652465e-12,0.15101513928300328,3523.056489730184,15.173180503576605,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-605W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,605.0,575.1,2.58,,,72.0,14.05,52.9,13.47,44.9,0.006744000000000001,-0.11532200000000001,43.2,1.8483209943055607,14.050002199425673,5.222990442345662e-12,0.15654185153919653,999999.7398126596,14.91030847004397,-0.301,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-144-BFN10-610W-DG,Aptos Solar Technology LLC,Mono-c-Si,1,610.0,579.9,2.58,,,72.0,14.1,53.1,13.53,45.1,0.006768,-0.115758,43.2,1.8564452715385193,14.100002129955097,5.334209181046718e-12,0.15105974882164258,999999.4846228177,15.076210764639487,-0.301,N,2025.7.3,6/23/2025,2.0,first_pass +Aptos Solar Technology LLC DNA-156-BFN10-610W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,610.0,578.6,2.8,,,78.0,14.17,54.93,13.38,45.59,0.00585221,-0.13172214000000002,43.5,1.9030984804199238,14.185216810947743,4.067135986545398e-12,0.2492268221570966,232.08174745364542,2.3449474175807414,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-156-BFN10-615W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,615.0,583.4,2.8,,,78.0,14.25,55.08,13.46,45.69,0.005885250000000001,-0.13208184,43.5,1.9075265523192837,14.265014685249726,4.0445600255308305e-12,0.25058523729517757,237.82314334232453,2.2487634124771003,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-156-BFN10-620W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,620.0,588.3,2.8,,,78.0,14.3,55.25,13.54,45.82,0.005905900000000001,-0.1324895,43.5,1.9111233101282785,14.312331154535638,3.931876130558699e-12,0.25145314843137606,291.6012468436478,1.9701239759999019,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-156-BFN10-625W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,625.0,593.1,2.8,,,78.0,14.35,55.4,13.61,45.92,0.00592655,-0.13284920000000003,43.5,1.9144120501699526,14.360497696541918,3.841683351574809e-12,0.2533249105488917,346.2866803385691,1.737920572291655,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Aptos Solar Technology LLC DNA-156-BFN10-630W-DG,Aptos Solar Technology LLC,Mono-c-Si,0,630.0,598.0,2.8,,,78.0,14.39,55.55,13.69,46.02,0.005943070000000001,-0.13320890000000002,43.5,1.9165096705718705,14.39694430774502,3.690403636352327e-12,0.2553614765057882,529.1602544380075,1.3634919078404661,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Arka Energy Inc AEP-821-00012-A,Arka Energy Inc,Mono-c-Si,0,77.0,70.9,0.52,,,17.0,8.33,11.56,7.93,9.71,0.0045815,-0.034414120000000006,44.57,0.454665368736919,8.330537018788664,7.549795781353072e-11,0.05772709060147535,895.4375636744727,8.747491064949754,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +Arka Energy Inc AEP-821-00015-A,Arka Energy Inc,Mono-c-Si,0,88.0,80.5,0.59,,,13.0,13.44,8.84,11.9,7.4,0.00628992,-0.025468040000000004,44.52,0.369536115545238,13.485339417556927,5.029567268257191e-10,0.025629065232651658,7.597244543515748,26.43821947577947,-0.4166,N,2025.7.3,6/23/2025,2.0,first_pass +ASTORIOS Holding Inc ASTR108BDG-390W-US,ASTORIOS Holding Inc,Mono-c-Si,1,390.0,362.1,1.94,,,54.0,13.54,36.7,12.79,30.5,0.0075823999999999996,-0.09780550000000002,46.08,1.3815330634249607,13.549294034261449,3.8873907118899184e-11,0.1515929732164933,220.84800140557843,10.821321171137768,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR108BDG-395W-US,ASTORIOS Holding Inc,Mono-c-Si,1,395.0,366.8,1.94,,,54.0,13.62,36.9,12.87,30.7,0.0076272,-0.09833850000000001,46.08,1.3896118011180354,13.628920906462643,3.9528600433859434e-11,0.14851976780422715,226.75265967513002,10.917390067974583,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR108BDG-400W-US,ASTORIOS Holding Inc,Mono-c-Si,1,400.0,371.6,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007671999999999999,-0.0988715,46.08,1.3976896207390601,13.70855778536917,4.018721689659721e-11,0.14548522145248718,232.90459829115468,11.012257539325056,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR108BDG-405W-US,ASTORIOS Holding Inc,Mono-c-Si,1,405.0,376.4,1.94,,,54.0,13.78,37.3,13.03,31.1,0.0077168,-0.0994045,46.08,1.4057665343234662,13.788204478616187,4.084971467180525e-11,0.14248860611549954,239.31965867525523,11.10595261005917,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR108BDG-410W-US,ASTORIOS Holding Inc,Mono-c-Si,1,410.0,381.2,1.94,,,54.0,13.86,37.5,13.1,31.3,0.0077616000000000004,-0.09993750000000001,46.08,1.4143671872399837,13.868526217529189,4.188890560025164e-11,0.13947302964740504,226.7237743819982,11.282390048429649,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR108BDG-415W-US,ASTORIOS Holding Inc,Mono-c-Si,1,415.0,386.0,1.94,,,54.0,13.94,37.7,13.18,31.5,0.0078064,-0.10047050000000002,46.08,1.4224425023806744,13.948177364205435,4.256290196716632e-11,0.1365481758963711,232.77446766906468,11.373397467021684,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR144BDG-530W-US,ASTORIOS Holding Inc,Mono-c-Si,1,530.0,495.8,2.58,,,72.0,13.65,49.4,12.91,41.1,0.008558550000000002,-0.1297738,45.45,1.825021643902791,13.659084267118946,2.3698342768643734e-11,0.2043445369897349,307.0476594802032,7.849894252346879,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR144BDG-535W-US,ASTORIOS Holding Inc,Mono-c-Si,1,535.0,500.6,2.58,,,72.0,13.71,49.6,12.96,41.3,0.00859617,-0.1302992,45.45,1.8336183292792658,13.719532075598224,2.421405316477722e-11,0.20125701220443315,289.468294143714,8.002947922670463,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR144BDG-540W-US,ASTORIOS Holding Inc,Mono-c-Si,1,540.0,505.4,2.58,,,72.0,13.77,49.8,13.02,41.5,0.00863379,-0.13082459999999999,45.45,1.8415394970758652,13.77925367471999,2.451456713821459e-11,0.19825399608801342,295.0133471115701,8.072248382433294,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR144BDG-545W-US,ASTORIOS Holding Inc,Mono-c-Si,1,545.0,510.2,2.58,,,72.0,13.83,50.0,13.07,41.7,0.008671410000000001,-0.13135,45.45,1.850137185916454,13.839678183336849,2.5040694782159164e-11,0.1952157580689703,278.96082134850235,8.223318349783264,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR144BDG-550W-US,ASTORIOS Holding Inc,Mono-c-Si,1,550.0,515.0,2.58,,,72.0,13.89,50.2,13.13,41.9,0.008709030000000001,-0.1318754,45.45,1.8580571493671636,13.899399566075704,2.5345600293616633e-11,0.19226636155338703,284.1173494743571,8.29104082507539,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +ASTORIOS Holding Inc ASTR144BDG-555W-US,ASTORIOS Holding Inc,Mono-c-Si,1,555.0,519.8,2.58,,,72.0,13.95,50.4,13.19,42.1,0.00874665,-0.13240079999999999,45.45,1.8659764515411663,13.959126380476071,2.5651803658228375e-11,0.18934426960031928,289.4195135464979,8.358141289268136,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +AUO Corporation PM024NB8_185,AUO Corporation,Mono-c-Si,0,185.0,173.6,0.92,,,24.0,13.79,17.17,13.12,14.12,0.00511609,-0.04081309,45.2,0.5996794410877392,13.79571015476981,5.041286003788284e-12,0.08982523546813431,216.9275725969825,5.349804189400868,-0.3158,Y,2025.7.3,6/23/2025,4.0,first_pass +AUO Corporation PM024NB8_190,AUO Corporation,Mono-c-Si,0,190.0,178.4,0.92,,,24.0,14.01,17.35,13.31,14.3,0.00519771,-0.041240950000000005,45.2,0.6069949205979259,14.01760925652042,5.366134740511799e-12,0.08660668118811024,159.45836569627582,5.761727645384347,-0.3158,Y,2025.7.3,6/23/2025,4.0,first_pass +AUO Corporation PM024NB8_195,AUO Corporation,Mono-c-Si,0,195.0,183.2,0.92,,,24.0,14.22,17.53,13.51,14.49,0.005275620000000001,-0.04166881,45.2,0.6141177097069811,14.227623932080787,5.658563597996724e-12,0.0826957875843659,154.2424683691422,6.0947643827783375,-0.3158,Y,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M409T130,Auxin Solar,Mono-c-Si,0,130.0,115.8,0.9796860000000001,1.471,0.666,36.0,7.83,21.6,7.24,17.96,0.004207059000000001,-0.0769824,46.0,0.9520535309527667,7.839793058020027,1.0657060606856267e-09,0.11274447730110274,90.1444066000006,13.025404233463314,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M409T135,Auxin Solar,Mono-c-Si,0,135.0,120.4,0.9796860000000001,1.471,0.666,36.0,8.1,21.58,7.41,18.22,0.00435213,-0.07691112,46.0,0.9662190183836955,8.108463962395554,1.5470291464282485e-09,0.06271440239531158,60.01760167253068,16.233071219496043,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M409T140,Auxin Solar,Mono-c-Si,0,140.0,125.0,0.9796860000000001,1.471,0.666,36.0,8.23,22.03,7.63,18.36,0.004421979,-0.07851492,46.0,0.9708597505404183,8.238750932197773,1.1195899130496324e-09,0.10324721770360044,97.10105559393459,13.012009099155785,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M409T145,Auxin Solar,Mono-c-Si,0,145.0,129.6,0.9796860000000001,1.471,0.666,36.0,8.42,22.46,7.9,18.36,0.004524066,-0.08004744000000001,46.0,0.9718603265981847,8.425491906410967,7.658107062421399e-10,0.1584878999864541,242.98823787778505,9.328275682329645,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M409T150,Auxin Solar,Mono-c-Si,0,150.0,134.2,0.9796860000000001,1.471,0.666,36.0,8.59,22.57,8.19,18.36,0.004615407,-0.08043948000000001,46.0,0.9731686222003945,8.590001287201542,7.272981655449963e-10,0.14961627545938308,999999.6850948252,8.664182818970055,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6M409T155,Auxin Solar,Mono-c-Si,0,155.0,138.8,0.9796860000000001,1.471,0.666,36.0,8.8,22.68,8.49,18.36,0.004728240000000001,-0.08083152,46.0,0.9814615864312715,8.800115056480946,8.100655764326147e-10,0.12132890433209381,9279.869506976705,9.403700065786234,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P610T210,Auxin Solar,Multi-c-Si,0,210.0,186.8,1.63777,1.646,0.995,60.0,7.6,35.94,7.09,29.64,0.00437608,-0.12011147999999999,47.6,1.5231167845498454,7.608307798238048,4.211611909373592e-10,0.24972809857455153,228.45207996844948,12.04459513842403,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T215,Auxin Solar,Multi-c-Si,0,215.0,191.3,1.63777,1.646,0.995,60.0,7.83,36.0,7.18,29.94,0.004508514000000001,-0.12031199999999999,47.6,1.548184735613635,7.8442734118097315,5.985998395660135e-10,0.1979925726277454,108.61327173234045,15.07142587628882,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T220,Auxin Solar,Multi-c-Si,0,220.0,195.9,1.63777,1.646,0.995,60.0,7.95,36.06,7.3,30.12,0.00457761,-0.12051252000000001,47.6,1.5535146275884748,7.962534038994422,6.340615598187755e-10,0.1746570058555927,110.78019612240138,15.464042422498862,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T225,Auxin Solar,Mono-c-Si,0,225.0,200.7,1.63777,1.646,0.995,60.0,8.11,37.02,7.5,30.0,0.0043575029999999996,-0.13193928000000002,46.0,1.6064708262573768,8.125580573918706,7.752035441230185e-10,0.31033087220511824,161.5334493597395,9.817518147440603,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T225,Auxin Solar,Multi-c-Si,0,225.0,200.5,1.63777,1.646,0.995,60.0,8.1,36.42,7.41,30.36,0.00466398,-0.12171564,47.6,1.5705865526772105,8.114832858613694,6.582864769502749e-10,0.1817046767341998,99.22618567959616,15.653262398844134,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T230,Auxin Solar,Mono-c-Si,0,230.0,205.3,1.63777,1.646,0.995,60.0,8.18,37.32,7.55,30.48,0.0043951139999999994,-0.13300848,46.0,1.628941177715168,8.195338480386184,8.908457047990221e-10,0.27257997350592633,145.36671864859488,10.995986522005781,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T230,Auxin Solar,Multi-c-Si,0,230.0,205.0,1.63777,1.646,0.995,60.0,8.17,36.6,7.55,30.48,0.004704285999999999,-0.12231720000000001,47.6,1.5682341678517608,8.181367550029515,5.787991493699657e-10,0.1885265468115325,135.4963923131,14.33521453887876,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T235,Auxin Solar,Mono-c-Si,0,235.0,209.8,1.63777,1.646,0.995,60.0,8.26,37.5,7.59,30.96,0.004438098,-0.13365,46.0,1.6518281145974623,8.274968950891395,1.1007855408513284e-09,0.21823982924031232,120.42669288135023,12.85152629695135,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T235,Auxin Solar,Multi-c-Si,0,235.0,209.6,1.63777,1.646,0.995,60.0,8.23,36.72,7.68,30.6,0.004738834000000001,-0.12271823999999999,47.6,1.5653306438583012,8.237333462845234,5.2318689429002e-10,0.18711965185038087,209.9955984255107,13.299640874766727,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T240,Auxin Solar,Mono-c-Si,0,240.0,214.4,1.63777,1.646,0.995,60.0,8.29,37.56,7.69,31.2,0.004454216999999999,-0.13386384,46.0,1.6514503466569905,8.299288159821664,1.0712755854217394e-09,0.19075980911430457,170.25967906839156,12.537686382193812,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T240,Auxin Solar,Multi-c-Si,0,240.0,214.2,1.63777,1.646,0.995,60.0,8.42,36.72,7.9,30.54,0.004848236,-0.12271823999999999,47.6,1.5588671229767872,8.425379074850317,4.889091799527406e-10,0.19308016638693526,302.23324971669865,12.45033595458315,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T245,Auxin Solar,Mono-c-Si,0,245.0,219.0,1.63777,1.646,0.995,60.0,8.32,37.62,7.78,31.5,0.004470336000000001,-0.13407767999999998,46.0,1.6542933276760416,8.324975228137525,1.0876838856962143e-09,0.1544800010921462,258.3346740403551,12.616708047720795,-0.4796,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T245,Auxin Solar,Multi-c-Si,0,245.0,218.8,1.63777,1.646,0.995,60.0,8.46,36.9,8.0,30.84,0.004871268000000001,-0.1233198,47.6,1.5641716047040335,8.461762473684589,4.784456628565026e-10,0.1727123710701691,829.0321068920052,12.181847870940938,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T250,Auxin Solar,Mono-c-Si,0,250.0,223.6,1.63777,1.646,0.995,60.0,8.59,37.62,8.17,30.6,0.004615407,-0.13407767999999998,46.0,1.6201004133248855,8.590002241890112,7.068601349769509e-10,0.2607423667196891,999999.9693452594,8.413633182017579,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P610T250,Auxin Solar,Multi-c-Si,0,250.0,223.4,1.63777,1.646,0.995,60.0,8.52,37.2,8.03,31.2,0.0049058159999999995,-0.12432240000000001,47.6,1.582925774718326,8.522951841668212,5.249310241952695e-10,0.1561579110341018,450.7239393206054,12.976643221833426,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T255,Auxin Solar,Mono-c-Si,0,255.0,228.2,1.63777,1.646,0.995,60.0,8.67,37.68,8.35,30.6,0.004658391,-0.13429152,46.0,1.631867977415856,8.670158021618743,8.127403933879103e-10,0.20148957826873826,11055.017946347238,9.56534954282136,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P610T255,Auxin Solar,Multi-c-Si,0,255.0,228.0,1.63777,1.646,0.995,60.0,8.56,37.5,8.08,31.56,0.004928848,-0.125325,47.6,1.5974875003942204,8.562252513018377,5.423086270281036e-10,0.1413463083596437,537.1443889440758,13.227132442702784,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T260,Auxin Solar,Mono-c-Si,0,260.0,232.9,1.63777,1.646,0.995,60.0,8.8,37.8,8.5,30.6,0.004728240000000001,-0.1347192,46.0,1.6368655274646726,8.800155384559122,8.226112405695474e-10,0.19469506484806648,11026.406427192414,9.540385260498434,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P610T260,Auxin Solar,Multi-c-Si,0,260.0,231.5,1.951195,1.961,0.995,72.0,7.83,43.2,7.24,35.93,0.004508514000000001,-0.1443744,47.6,1.8490177319711012,7.840986830584401,5.412478209789915e-10,0.23992596690187193,170.98839100966282,14.105081304694274,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T265,Auxin Solar,Mono-c-Si,0,265.0,235.7,1.951195,1.961,0.995,72.0,8.11,44.42,7.36,36.0,0.004324252,-0.14409848000000003,47.9,1.8791908080381348,8.140946852043207,4.177729832386635e-10,0.38799957843979793,101.68002745277616,14.922097543877584,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T265,Auxin Solar,Multi-c-Si,0,265.0,236.0,1.951195,1.961,0.995,72.0,7.95,43.27,7.33,36.14,0.00457761,-0.14460834,47.6,1.8596301454293285,7.961118143040083,6.023879539458367e-10,0.21138421659960557,151.1497603178517,14.969883894125921,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T270,Auxin Solar,Mono-c-Si,0,270.0,247.3,1.6268799999999999,1.64,0.992,60.0,9.07,38.45,8.69,31.06,0.003628,-0.11535000000000001,44.58,1.5232515114998433,9.07000267005369,9.888261158209707e-11,0.2942785696242183,999821.775638847,9.70493549427072,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6M612T270,Auxin Solar,Mono-c-Si,0,270.0,240.3,1.951195,1.961,0.995,72.0,8.14,44.64,7.44,36.21,0.0043402480000000005,-0.14481216000000002,47.9,1.8819031774159458,8.165745526630062,3.892769272110789e-10,0.3845052437360585,121.56957998971899,14.208487849922351,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T275,Auxin Solar,Mono-c-Si,0,275.0,252.0,1.6268799999999999,1.64,0.992,60.0,9.2,38.77,8.79,31.29,0.00368,-0.11631000000000001,44.58,1.533383539883375,9.20000283675464,9.618428321839612e-11,0.30828640076092995,999998.4510759347,9.335898059512848,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6M612T275,Auxin Solar,Mono-c-Si,0,275.0,244.9,1.951195,1.961,0.995,72.0,8.18,44.78,7.52,36.58,0.004361576,-0.14526632000000003,47.9,1.8895113350852686,8.19977439541357,4.021321104197974e-10,0.34430323877061547,142.42663934449376,14.445573833560278,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T275,Auxin Solar,Multi-c-Si,0,275.0,248.3,1.6268799999999999,1.64,0.992,60.0,9.1,38.91,8.49,32.4,0.00455,-0.124512,47.69,1.593779634286802,9.109990849516391,2.2204177339485275e-10,0.19885663349672095,181.12528337132244,9.653525875584037,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T275,Auxin Solar,Multi-c-Si,0,275.0,245.2,1.951195,1.961,0.995,72.0,8.17,43.92,7.52,36.58,0.004704285999999999,-0.14678064000000002,47.6,1.8863055831257367,8.182916893782483,6.084426967964598e-10,0.22434235262631744,141.89767242943375,14.81398883600667,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T275G,Auxin Solar,Multi-c-Si,0,275.0,245.2,1.951195,1.961,0.995,72.0,8.17,43.92,7.52,36.58,0.004704285999999999,-0.14678064000000002,47.6,1.8863055831257367,8.182916893782483,6.084426967964598e-10,0.22434235262631744,141.89767242943375,14.81398883600667,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T280,Auxin Solar,Mono-c-Si,0,280.0,256.7,1.6268799999999999,1.64,0.992,60.0,9.34,39.1,8.88,31.53,0.0037359999999999997,-0.1173,44.58,1.5424590337478223,9.34000307795881,9.148636900621157e-11,0.32948322310498646,999999.8580004738,8.764250947263442,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6M612T280,Auxin Solar,Mono-c-Si,0,280.0,249.5,1.951195,1.961,0.995,72.0,8.21,44.86,7.6,36.86,0.004377572000000001,-0.14552584000000002,47.9,1.8920569355312336,8.224202392545555,4.025025476945049e-10,0.31155023249472774,180.0983590348192,14.396795081789696,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T280,Auxin Solar,Multi-c-Si,0,280.0,253.0,1.6268799999999999,1.64,0.992,60.0,9.24,39.24,8.58,32.64,0.004620000000000001,-0.125568,47.69,1.610479404467057,9.252824165787692,2.353001317113256e-10,0.2013192435461544,145.05348069964526,10.049811965280302,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T280,Auxin Solar,Multi-c-Si,0,280.0,249.8,1.951195,1.961,0.995,72.0,8.23,44.06,7.63,36.72,0.004738834000000001,-0.14724852000000002,47.6,1.8852444698748594,8.239970196821574,5.664777449550359e-10,0.22205429846587657,183.29698795053153,14.056554145431086,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T280G,Auxin Solar,Multi-c-Si,0,280.0,249.8,1.951195,1.961,0.995,72.0,8.23,44.06,7.63,36.72,0.004738834000000001,-0.14724852000000002,47.6,1.8852444698748594,8.239970196821574,5.664777449550359e-10,0.22205429846587657,183.29698795053153,14.056554145431086,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T285,Auxin Solar,Mono-c-Si,0,285.0,261.4,1.6268799999999999,1.64,0.992,60.0,9.48,39.43,8.97,31.76,0.0037920000000000007,-0.11828999999999999,44.58,1.5551320082061078,9.482588698803452,9.205381342631495e-11,0.3400815565507167,1245.4032702136212,8.698895849907192,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T285,Auxin Solar,Mono-c-Si,0,285.0,254.0,1.951195,1.961,0.995,72.0,8.39,44.21,7.77,36.72,0.004473548,-0.14341724,47.9,1.875898750884232,8.40174673811269,4.739086637859454e-10,0.24077437019166711,171.97089985775222,15.71737004551376,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T285,Auxin Solar,Multi-c-Si,0,285.0,257.6,1.6268799999999999,1.64,0.992,60.0,9.38,39.57,8.67,32.89,0.004690000000000001,-0.12662400000000001,47.69,1.6274644463624959,9.395666170396591,2.5013474803213066e-10,0.2023786913759492,121.17270169091216,10.477029025888136,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T285,Auxin Solar,Multi-c-Si,0,285.0,256.9,1.951195,1.961,0.995,72.0,8.32,44.21,7.75,36.79,0.004992832000000001,-0.14522985,46.2,1.8684486457386293,8.328752046457947,4.306576621668952e-10,0.23468153172752876,223.0964529050987,13.359806922338521,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T285G,Auxin Solar,Multi-c-Si,0,285.0,256.9,1.951195,1.961,0.995,72.0,8.32,44.21,7.75,36.79,0.004992832000000001,-0.14522985,46.2,1.8684486457386293,8.328752046457947,4.306576621668952e-10,0.23468153172752876,223.0964529050987,13.359806922338521,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B290,Auxin Solar,Mono-c-Si,1,290.0,269.4,1.653,,,60.0,9.62,39.77,9.06,32.0,0.004232799999999999,-0.11016290000000002,43.78,1.499046994169934,9.629983514999843,2.8608760575500798e-11,0.3592821594727659,346.2001573490751,7.044475080218176,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T290,Auxin Solar,Mono-c-Si,0,290.0,266.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.77,9.06,32.0,0.003848,-0.11931000000000001,44.58,1.5712623604212808,9.627340405234149,9.707870375162008e-11,0.342447118018945,448.7956020514584,9.054593276658517,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T290,Auxin Solar,Mono-c-Si,0,290.0,258.6,1.951195,1.961,0.995,72.0,8.48,44.43,7.9,36.72,0.004521536,-0.14413092000000002,47.9,1.8736608402053134,8.489978572660018,4.172732727241059e-10,0.26818035176963123,227.90530060846658,14.408766490330018,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P610T290,Auxin Solar,Multi-c-Si,0,290.0,262.3,1.6268799999999999,1.64,0.992,60.0,9.52,39.91,8.75,33.14,0.00476,-0.127712,47.69,1.6456855505199879,9.539288461821721,2.6848139086315726e-10,0.2043463797897307,100.85706236239369,10.99779376095269,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T290,Auxin Solar,Multi-c-Si,0,290.0,261.5,1.951195,1.961,0.995,72.0,8.46,44.28,7.96,36.79,0.005076846,-0.14545980000000003,46.2,1.85944282607089,8.464442239985166,3.806614873241127e-10,0.2423388701439107,461.52103482006305,12.043239848123871,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T290G,Auxin Solar,Multi-c-Si,0,290.0,261.5,1.951195,1.961,0.995,72.0,8.46,44.28,7.96,36.79,0.005076846,-0.14545980000000003,46.2,1.85944282607089,8.464442239985166,3.806614873241127e-10,0.2423388701439107,461.52103482006305,12.043239848123871,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B295,Auxin Solar,Mono-c-Si,1,295.0,274.1,1.653,,,60.0,9.77,40.11,9.15,32.24,0.004298799999999999,-0.11110470000000001,43.78,1.5150707421278413,9.786304611001572,3.053524505281037e-11,0.36131394749443047,216.50546143133232,7.497689179179613,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T295,Auxin Solar,Mono-c-Si,0,295.0,270.4,1.6268799999999999,1.64,0.992,60.0,9.77,40.11,9.15,32.24,0.0041034,-0.1131102,46.67,1.530069215334997,9.785671253536337,3.960261725042655e-11,0.35782532897941155,223.0806574585144,7.8432896838665584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T295,Auxin Solar,Mono-c-Si,0,295.0,263.2,1.951195,1.961,0.995,72.0,8.52,44.57,8.04,36.72,0.004542864,-0.14458508,47.9,1.8632054366318653,8.523148756640882,3.458198177603366e-10,0.28736083453973316,777.5497827177953,12.591488472667029,-0.4485,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T295,Auxin Solar,Multi-c-Si,0,295.0,266.1,1.951195,1.961,0.995,72.0,8.49,44.42,8.0,37.01,0.005094849,-0.1459197,46.2,1.8668082423708057,8.493616028324812,3.8989141749737933e-10,0.2273968015188424,533.9004685536831,12.22374178035016,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T295G,Auxin Solar,Multi-c-Si,0,295.0,266.1,1.951195,1.961,0.995,72.0,8.49,44.42,8.0,37.01,0.005094849,-0.1459197,46.2,1.8668082423708057,8.493616028324812,3.8989141749737933e-10,0.2273968015188424,533.9004685536831,12.22374178035016,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B300,Auxin Solar,Mono-c-Si,1,300.0,278.9,1.653,,,60.0,9.91,40.45,9.24,32.48,0.0043604,-0.11204650000000002,43.78,1.5303554178594778,9.93164122232795,3.2143633130016645e-11,0.3636221702732,166.51073140250048,7.838010671869026,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T300,Auxin Solar,Mono-c-Si,0,300.0,275.1,1.6268799999999999,1.64,0.992,60.0,9.91,40.45,9.24,32.48,0.0041622000000000004,-0.11406899999999999,46.67,1.5455351056335254,9.930945213767378,4.169229983689515e-11,0.3601251937774448,170.3893201772202,8.18489238767737,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T300,Auxin Solar,Mono-c-Si,0,300.0,267.8,1.951195,1.961,0.995,72.0,8.58,44.71,8.17,36.72,0.004574856,-0.14503924,47.9,1.8642303889691736,8.580002438008703,3.294296716888916e-10,0.28404631832403854,999999.9754555876,12.066074019021617,-0.4485,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P612T300,Auxin Solar,Multi-c-Si,0,300.0,270.7,1.951195,1.961,0.995,72.0,8.54,44.86,8.05,37.66,0.005124854,-0.1473651,46.2,1.893026290462884,8.543068638886961,4.3203366519616086e-10,0.1871541859898734,520.8488508709738,13.107041581006257,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T300G,Auxin Solar,Multi-c-Si,0,300.0,270.7,1.951195,1.961,0.995,72.0,8.54,44.86,8.05,37.66,0.005124854,-0.1473651,46.2,1.893026290462884,8.543068638886961,4.3203366519616086e-10,0.1871541859898734,520.8488508709738,13.107041581006257,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B305,Auxin Solar,Mono-c-Si,1,305.0,283.6,1.653,,,60.0,10.06,40.79,9.32,32.73,0.0044264000000000005,-0.1129883,43.78,1.5474716944553926,10.089446674107261,3.4826151585336006e-11,0.3643607657690401,124.47821211606572,8.43227714425943,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T305,Auxin Solar,Mono-c-Si,0,305.0,279.8,1.6268799999999999,1.64,0.992,60.0,10.061831783469275,40.791992844343525,9.319077416024621,32.72856167881353,0.004225969349057096,-0.11503341982104874,46.67,1.5630767855278895,10.09084521074077,4.5268101294795724e-11,0.36118505919228383,125.25867191411358,8.798278225543383,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T305,Auxin Solar,Mono-c-Si,0,305.0,272.4,1.951195,1.961,0.995,72.0,8.72,44.86,8.31,36.72,0.0046495040000000005,-0.14552584000000002,47.9,1.8682528775355243,8.720002548937462,3.2534844919484213e-10,0.2922006211795013,999999.9378833934,11.80718645471449,-0.4485,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P612T305,Auxin Solar,Multi-c-Si,0,305.0,275.4,1.951195,1.961,0.995,72.0,8.56,45.0,8.08,37.87,0.005136856,-0.147825,46.2,1.9001308486761508,8.562450132080375,4.401700472371073e-10,0.17432166630681611,609.0258543100819,13.251881910479705,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T305G,Auxin Solar,Multi-c-Si,0,305.0,275.4,1.951195,1.961,0.995,72.0,8.56,45.0,8.08,37.87,0.005136856,-0.147825,46.2,1.9001308486761508,8.562450132080375,4.401700472371073e-10,0.17432166630681611,609.0258543100819,13.251881910479705,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B310,Auxin Solar,Mono-c-Si,1,310.0,288.4,1.653,,,60.0,10.21,41.14,9.4,32.97,0.0044924000000000006,-0.11395780000000001,43.78,1.5645459390254493,10.247591525162067,3.740599700190868e-11,0.3673964389914168,99.78625935615588,8.953840215073315,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T310,Auxin Solar,Mono-c-Si,0,310.0,284.5,1.6268799999999999,1.64,0.992,60.0,10.212759260221313,41.138724783520445,9.40133913344224,32.97402589140463,0.004289358889292952,-0.11601120388952765,46.67,1.5803211395109158,10.249584956120156,4.87015014458933e-11,0.3631277304582071,100.70512037083068,9.333972170637521,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T310,Auxin Solar,Mono-c-Si,0,310.0,277.0,1.951195,1.961,0.995,72.0,8.79,45.0,8.45,36.72,0.004686828,-0.14598000000000003,47.9,1.8796824755780566,8.790189786068506,3.5213311976981295e-10,0.25443620117802607,11784.340483985601,12.452323242250348,-0.4485,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P612T310,Auxin Solar,Multi-c-Si,0,310.0,277.3,1.951195,1.961,0.995,72.0,8.62,45.22,8.16,38.02,0.004963396,-0.15112524,47.6,1.922255382413365,8.621314312506998,5.212563713276657e-10,0.17551296067560437,1151.1131722075531,12.78924786924764,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B315,Auxin Solar,Mono-c-Si,1,315.0,293.2,1.653,,,60.0,10.37,41.49,9.48,33.22,0.0045628,-0.11492730000000002,43.78,1.582684792576457,10.417057119709582,4.0824037615453045e-11,0.3688126918991056,81.27543021056115,9.6153536861459,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T315,Auxin Solar,Mono-c-Si,0,315.0,289.3,1.6268799999999999,1.64,0.992,60.0,10.365950649124631,41.48840394418037,9.481859687935021,33.221331085590165,0.0043536992726323455,-0.11699729912258863,46.67,1.5980434642065233,10.411277758501392,5.2614928105194705e-11,0.36504081171887237,83.48194129255951,9.909833158916406,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T315,Auxin Solar,Mono-c-Si,0,315.0,281.6,1.951195,1.961,0.995,72.0,8.89,45.22,8.58,36.72,0.0047401480000000005,-0.14669368,47.9,1.8879697527472572,8.890159921257549,3.521107441450721e-10,0.2503870276099685,13918.85510918097,12.348868498239979,-0.4485,N,2025.7.3,6/23/2025,2.0,first_pass +Auxin Solar AXN6P612T315,Auxin Solar,Multi-c-Si,0,315.0,281.9,1.951195,1.961,0.995,72.0,8.67,45.58,8.24,38.45,0.004992186,-0.15232836,47.6,1.9369989783006765,8.670009300656798,5.230145277300056e-10,0.15903732292001896,148261.98009419083,12.752331251016333,-0.4501,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610B320,Auxin Solar,Mono-c-Si,1,320.0,297.9,1.653,,,60.0,10.52,41.84,9.56,33.47,0.0046288,-0.11589680000000002,43.78,1.600099300244771,10.575517308265056,4.3955758631766524e-11,0.3705051373405951,70.2071876014965,10.166091875340946,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T320,Auxin Solar,Mono-c-Si,0,320.0,294.0,1.6268799999999999,1.64,0.992,60.0,10.521439908861499,41.8410553777059,9.56066044393779,33.470491068732095,0.0044190047617218295,-0.11799177616513062,46.67,1.6162355668345512,10.575982421678662,5.706104107569926e-11,0.3669254145349315,70.78118591616877,10.523238448149774,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T320,Auxin Solar,Mono-c-Si,0,320.0,293.0,1.9403519999999999,1.956,0.992,72.0,9.46,45.97,8.58,37.3,0.003784000000000001,-0.13791,44.58,1.8610817268549942,9.499982811270087,1.6783617945234003e-10,0.3591308387283655,84.97095878720428,14.275087302938694,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T320,Auxin Solar,Multi-c-Si,0,320.0,288.7,1.9403519999999999,1.956,0.992,72.0,9.38,45.51,8.75,36.59,0.004690000000000001,-0.145632,47.69,1.8277110862434502,9.395964606506988,1.412471412035408e-10,0.4005887081140009,235.3657953842325,5.457233575336352,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M610T325,Auxin Solar,Mono-c-Si,0,325.0,298.7,1.6268799999999999,1.64,0.992,60.0,10.67926150749442,42.1967043484164,9.637762544292126,33.721519751747586,0.004485289833147657,-0.11899470626253422,46.67,1.6349219577939422,10.743756608702647,6.213132701578504e-11,0.36877508278027,61.06270881151508,11.176244469037362,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T325,Auxin Solar,Mono-c-Si,0,325.0,297.7,1.9403519999999999,1.956,0.992,72.0,9.52,46.38,8.67,37.48,0.0038079999999999998,-0.13914,44.58,1.8690878296947253,9.558650681823933,1.5158756332246252e-10,0.38119720402614665,93.89219788484476,13.267176701287859,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T325,Auxin Solar,Multi-c-Si,0,325.0,293.4,1.9403519999999999,1.956,0.992,72.0,9.44,45.79,8.81,36.88,0.00472,-0.146528,47.69,1.8403489993664293,9.455412523580435,1.4490430009508047e-10,0.39183891957415146,239.99701319263525,5.619422420359781,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M325B,Auxin Solar,Mono-c-Si,0,325.0,302.7,1.64,,,60.0,10.21,39.92,9.58,33.92,0.0046966,-0.1029936,45.14,1.5051972680217247,10.217921160973235,3.0286762379009935e-11,0.13323164876534813,171.7292635761144,14.979276379102112,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T330,Auxin Solar,Mono-c-Si,0,330.0,302.4,1.9403519999999999,1.956,0.992,72.0,9.57,46.76,8.75,37.71,0.0038280000000000002,-0.14028,44.58,1.8782044929573198,9.606055909181267,1.4110440291672723e-10,0.39294308359316454,104.29539816458711,12.552372728373932,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T330,Auxin Solar,Multi-c-Si,0,330.0,298.0,1.9403519999999999,1.956,0.992,72.0,9.5,46.08,8.87,37.22,0.004750000000000001,-0.147456,47.69,1.8545637334496166,9.514742576056802,1.50950624956238e-10,0.3777410053186933,243.41334609290845,5.913281977164679,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M330B,Auxin Solar,Mono-c-Si,0,330.0,307.5,1.64,,,60.0,10.24,40.27,9.63,34.27,0.0047104,-0.10389660000000002,45.14,1.517851377293383,10.24673009463286,3.0165462524479866e-11,0.12817395070674278,195.0197337362405,14.904676120692113,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T335,Auxin Solar,Mono-c-Si,0,335.0,307.1,1.9403519999999999,1.956,0.992,72.0,9.61,47.04,8.82,37.98,0.0038439999999999998,-0.14112,44.58,1.8868722859099445,9.642130538438485,1.375601974225539e-10,0.3879317144076514,116.02743233655329,12.270439460413943,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6P612T335,Auxin Solar,Multi-c-Si,0,335.0,302.7,1.9403519999999999,1.956,0.992,72.0,9.56,46.37,8.94,37.55,0.00478,-0.14838400000000002,47.69,1.8674042078030457,9.573102996105542,1.545275739573512e-10,0.3652093514705903,266.4582663237074,6.054766076694603,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M335B,Auxin Solar,Mono-c-Si,0,335.0,312.3,1.64,,,60.0,10.28,40.75,9.64,34.75,0.0047288,-0.105135,45.14,1.5397621892269593,10.287383324637553,3.222818710981937e-11,0.12010751209605712,167.22889641003044,15.498784907694006,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B340,Auxin Solar,Mono-c-Si,1,340.0,315.7,1.969,,,72.0,9.64,47.18,8.96,38.32,0.004241600000000001,-0.13068860000000002,43.78,1.7986314119656177,9.662043258559773,3.8027477010769686e-11,0.37952216452852294,165.9733608867506,9.573838924399913,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T340,Auxin Solar,Mono-c-Si,0,340.0,311.8,1.9403519999999999,1.956,0.992,72.0,9.64,47.18,8.96,38.32,0.0038560000000000005,-0.14154,44.58,1.8862342479091858,9.65897249593961,1.2888739033426714e-10,0.3586593911534742,182.23625738273012,11.608569810026566,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M340B,Auxin Solar,Mono-c-Si,0,340.0,317.1,1.64,,,60.0,10.31,41.1,9.69,35.1,0.0047426000000000005,-0.10603800000000001,45.14,1.5523788991537943,10.31629099227398,3.206984873757107e-11,0.11516787123246927,188.74300072625195,15.415556338710068,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B345,Auxin Solar,Mono-c-Si,1,345.0,320.4,1.969,,,72.0,9.72,47.28,8.98,38.4,0.0042768,-0.13096560000000002,43.78,1.8078676539043064,9.747900680528641,4.118649463962996e-11,0.3772247806966452,131.41704193008505,10.233015173257304,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T345,Auxin Solar,Mono-c-Si,0,345.0,315.8,1.9403519999999999,1.956,0.992,72.0,9.72,47.28,8.98,38.4,0.0038880000000000004,-0.14184,44.6,1.9163111001523923,9.743741252569448,1.814428788835286e-10,0.35147468608065724,143.89864584178102,14.666712116471313,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M345B,Auxin Solar,Mono-c-Si,0,345.0,321.9,1.64,,,60.0,10.34,41.46,9.73,35.46,0.0047564,-0.10696680000000001,45.14,1.56619797080005,10.345606798039062,3.232578313372645e-11,0.10991269224066037,202.69987159328167,15.457472999460874,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B350,Auxin Solar,Mono-c-Si,1,350.0,325.2,1.969,,,72.0,9.81,47.37,9.1,38.48,0.0043164,-0.13121490000000002,43.78,1.8077968387641377,9.834270360214223,3.969870560172485e-11,0.3736853315899096,151.04238709670688,9.8080269190564,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T350,Auxin Solar,Mono-c-Si,0,350.0,320.5,1.9403519999999999,1.956,0.992,72.0,9.81,47.37,9.1,38.48,0.003924,-0.14211,44.6,1.916039192933934,9.83034389103705,1.749519876467694e-10,0.34834172972999017,167.97339838274996,14.229995839445955,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B355,Auxin Solar,Mono-c-Si,1,355.0,329.9,1.969,,,72.0,9.9,47.47,9.21,38.55,0.004356,-0.13149190000000002,43.78,1.8087350318462225,9.921800394625727,3.8559645802777165e-11,0.3725400823383414,169.1779860899729,9.457641333405038,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T355,Auxin Solar,Mono-c-Si,0,355.0,325.5,1.9403519999999999,1.956,0.992,72.0,9.898520572643996,47.465658561456,9.208248308672879,38.552392170576006,0.004157378640510479,-0.13385315714330592,46.67,1.826812329847677,9.919665167918762,5.012715363806859e-11,0.3675994143669868,172.08607556276885,9.82881105488008,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B360,Auxin Solar,Mono-c-Si,1,360.0,334.7,1.969,,,72.0,9.99,47.56,9.32,38.63,0.0043955999999999995,-0.13174120000000003,43.78,1.8098098242342322,10.009222267172992,3.7729343957614494e-11,0.36905506780165304,191.801525929123,9.174135608542356,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T360,Auxin Solar,Mono-c-Si,0,360.0,330.2,1.9403519999999999,1.956,0.992,72.0,9.98760725779779,47.56058987857892,9.319303340142914,38.62949695491716,0.004194795048275073,-0.13412086345759253,46.67,1.8277007997887391,10.006039406257855,4.8803593152253205e-11,0.36511524095647263,197.84062209165737,9.500579182678859,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B365,Auxin Solar,Mono-c-Si,1,365.0,339.5,1.969,,,72.0,10.08,47.66,9.43,38.71,0.004435199999999999,-0.1320182,43.78,1.8111252042027433,10.096688787366835,3.6838871099786216e-11,0.3667028216080695,221.487901739539,8.873509268724197,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T365,Auxin Solar,Mono-c-Si,0,365.0,334.9,1.9403519999999999,1.956,0.992,72.0,10.07749572311797,47.655711058336074,9.429878352051906,38.706755948826995,0.0042325482037095475,-0.13438910518450772,46.67,1.8287844251569434,10.09334347862091,4.7633095976526984e-11,0.36263054169784914,230.594660699916,9.195862771756783,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B370,Auxin Solar,Mono-c-Si,1,370.0,344.2,1.969,,,72.0,10.17,47.75,9.54,38.78,0.004474799999999999,-0.1322675,43.78,1.812074467258471,10.184158871832455,3.597309230456775e-11,0.36453194772625663,261.83512469623605,8.575407810537381,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T370,Auxin Solar,Mono-c-Si,0,370.0,339.6,1.9403519999999999,1.956,0.992,72.0,10.16819318462603,47.75102248045275,9.539974818197045,38.78416946072465,0.004270641137542933,-0.13465788339487675,46.67,1.8300549612475816,10.181585445104714,4.6601399005464755e-11,0.3601483998219031,273.44588055989294,8.913551425975726,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B375,Auxin Solar,Mono-c-Si,1,375.0,349.0,1.969,,,72.0,10.26,47.85,9.65,38.86,0.0045144,-0.1325445,43.78,1.8135070377307068,10.271620540761152,3.5177019459858046e-11,0.3622359539544312,319.82513034029927,8.291226056420347,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T375,Auxin Solar,Mono-c-Si,0,375.0,344.3,1.9403519999999999,1.956,0.992,72.0,10.259706923287665,47.84652452541365,9.649594208404519,38.8617377996461,0.0043090769077808195,-0.13492719916166648,46.67,1.8315048764499766,10.27077330284935,4.569625026362577e-11,0.35767146017998885,331.5993666249229,8.652636732330645,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612B380,Auxin Solar,Mono-c-Si,1,380.0,353.8,1.969,,,72.0,10.35,47.94,9.76,38.94,0.004554,-0.13279380000000002,43.78,1.814812969569242,10.359074096450595,3.4521088550757016e-11,0.3589291913248221,409.39802963989877,8.039684860219491,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T380,Auxin Solar,Mono-c-Si,0,380.0,349.1,1.9403519999999999,1.956,0.992,72.0,10.352044285597252,47.94221757446448,9.758737988539501,38.93946127524539,0.004347858599950846,-0.13519705355998982,46.67,1.833127222056348,10.360915047291538,4.490706735860998e-11,0.3552020067315148,414.51536401520326,8.412182454359852,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN6M612T385,Auxin Solar,Mono-c-Si,0,385.0,353.8,1.9403519999999999,1.956,0.992,72.0,10.445212684167625,48.03810200961341,9.867407620516094,39.01734019779588,0.004386989327350404,-0.1354674476671098,46.67,1.8349155959537815,10.452018682554433,4.4224711529773926e-11,0.3527419997477343,541.355603538449,8.191322460264635,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M390B,Auxin Solar,Mono-c-Si,0,390.0,363.6,1.96,,,72.0,10.21,47.9,9.58,40.07,0.0046966,-0.123582,45.14,1.7837643780286578,10.221303955161096,2.1759985531297266e-11,0.23737232762154317,214.4003090057696,11.937987364125014,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M390W,Auxin Solar,Mono-c-Si,0,390.0,363.3,1.96,,,72.0,10.21,47.9,9.58,40.07,0.0043903,-0.126456,45.14,1.7888189458615038,10.22117684804564,2.3478368280959195e-11,0.23619885275759298,215.7665820554059,10.091091773130609,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M395B,Auxin Solar,Mono-c-Si,0,395.0,371.0,1.895,,,54.0,13.59,37.03,12.75,31.0,0.005436,-0.09035320000000001,45.0,1.3234846641624265,13.607477930590637,9.375953793283955e-12,0.1456403648545594,113.24295811718916,8.12200842513255,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M395B,Auxin Solar,Mono-c-Si,0,395.0,368.4,1.96,,,72.0,10.24,48.33,9.6,41.13,0.0047104,-0.12469140000000001,45.14,1.8076755317242488,10.248277457413563,2.4472399445718188e-11,0.15692703169184014,194.1336247405195,12.993505875336957,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M395W,Auxin Solar,Mono-c-Si,0,395.0,368.1,1.96,,,72.0,10.24,48.33,9.6,41.13,0.0044031999999999995,-0.12759120000000002,45.14,1.821579303878259,10.247986530691284,3.0022656969390303e-11,0.15366274410229586,197.02002870226747,12.286206598115124,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M400B,Auxin Solar,Mono-c-Si,0,400.0,375.9,1.895,,,54.0,13.68,37.2,12.84,31.17,0.005472,-0.09076800000000002,45.0,1.3033993814476432,13.698215016580571,5.380215014252579e-12,0.1475895485598045,110.84398510305971,3.2630286495063174,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M400B,Auxin Solar,Mono-c-Si,0,400.0,373.2,1.96,,,72.0,10.27,48.76,9.63,41.56,0.0047242,-0.1258008,45.14,1.8337121218611112,10.277682578277593,2.83859477666147e-11,0.1482402775241707,198.1662408674921,14.329501854443395,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M400W,Auxin Solar,Mono-c-Si,0,400.0,372.9,1.96,,,72.0,10.27,48.76,9.63,41.56,0.0044161,-0.1287264,45.14,1.8390570656675826,10.277574797784286,3.067058683314419e-11,0.14698912730554092,199.2895900583374,12.453261002551185,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M405B,Auxin Solar,Mono-c-Si,0,405.0,380.7,1.895,,,54.0,13.78,37.36,12.92,31.36,0.005512,-0.0911584,45.0,1.3374294365510613,13.797477729509938,9.934588936008535e-12,0.13746686074142433,108.38326244512854,8.51504341069087,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M405B,Auxin Solar,Mono-c-Si,0,405.0,378.0,1.96,,,72.0,10.29,49.04,9.68,41.84,0.0047334,-0.1265232,45.14,1.842176491149713,10.29630664116362,2.770858097416223e-11,0.14470414625703848,236.10122004222436,14.073653363260517,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M405W,Auxin Solar,Mono-c-Si,0,405.0,377.7,1.96,,,72.0,10.29,49.04,9.68,41.84,0.004424699999999999,-0.12946560000000001,45.14,1.847527665686968,10.296210547282062,2.993338164026331e-11,0.14345808534538457,237.6897944515607,12.200221694278975,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M410B,Auxin Solar,Mono-c-Si,0,410.0,385.5,1.895,,,54.0,13.86,37.54,13.0,31.55,0.005544,-0.0915976,45.0,1.3444387513647427,13.87688405327354,1.0113806816468069e-11,0.1339397879048613,109.95022549272706,8.62087567458758,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M410B,Auxin Solar,Mono-c-Si,0,410.0,382.8,1.96,,,72.0,10.32,49.47,9.7,42.27,0.0047472,-0.12763259999999998,45.14,1.8605243411591872,10.32631981881607,2.8643618588068058e-11,0.13787543487336257,225.1448240371446,14.357996085603588,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M410W,Auxin Solar,Mono-c-Si,0,410.0,382.5,1.96,,,72.0,10.32,49.47,9.7,42.27,0.0044376,-0.1306008,45.14,1.8659479335568532,10.32622237947332,3.094908119060596e-11,0.13661356130985608,226.57762463341285,12.481243682358052,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M415B,Auxin Solar,Mono-c-Si,0,415.0,386.4,1.94,,,54.0,13.69,38.04,12.9,32.18,0.0084878,-0.10118640000000001,46.5,1.4353888644127277,13.698996616587152,4.166072604612347e-11,0.10666935535234605,162.3169634937796,11.49756917265762,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M415W,Auxin Solar,Mono-c-Si,0,415.0,386.7,1.94,,,54.0,13.69,38.04,12.9,32.18,0.0084878,-0.10118640000000001,46.3,1.4353888644127277,13.698996616587152,4.166072604612347e-11,0.10666935535234605,162.3169634937796,11.49756917265762,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M415B,Auxin Solar,Mono-c-Si,0,415.0,387.6,1.96,,,72.0,10.35,49.9,9.72,42.7,0.004761,-0.128742,45.14,1.8788871882895581,10.356298456561573,2.9598306357255634e-11,0.13106898763853578,215.38038971037332,14.639322844787346,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M415W,Auxin Solar,Mono-c-Si,0,415.0,387.3,1.96,,,72.0,10.35,49.9,9.72,42.7,0.0044505,-0.13173600000000002,45.14,1.8843835859386615,10.356199613929963,3.1986383759756614e-11,0.1297912621750961,216.68116529418248,12.759311653166291,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M420B,Auxin Solar,Mono-c-Si,0,420.0,391.2,1.94,,,54.0,13.71,38.26,12.89,32.62,0.0085002,-0.1017716,46.5,1.4283634617300018,13.71000230978376,3.192049243860015e-11,0.0879712563084486,522173.5710659001,10.540952928864177,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M420W,Auxin Solar,Mono-c-Si,0,420.0,391.5,1.94,,,54.0,13.71,38.26,12.89,32.62,0.0085002,-0.1017716,46.3,1.4283634617300018,13.71000230978376,3.192049243860015e-11,0.0879712563084486,522173.5710659001,10.540952928864177,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXNG1M420W,Auxin Solar,Mono-c-Si,0,420.0,392.1,1.96,,,72.0,10.38,50.18,9.77,42.98,0.0044634,-0.13247520000000002,45.14,1.893716531807461,10.385321560957792,3.160779788326864e-11,0.12601975695114326,245.8085316055988,12.614523241946232,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M425B,Auxin Solar,Mono-c-Si,0,425.0,396.0,1.94,,,54.0,13.72,38.37,12.94,32.89,0.0085064,-0.10206420000000001,46.5,1.4569290770909813,13.725776344947771,4.9251580540702445e-11,0.06926265237447138,164.5129587246859,13.00205098372625,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M425W,Auxin Solar,Mono-c-Si,0,425.0,396.3,1.94,,,54.0,13.72,38.37,12.94,32.89,0.0085064,-0.10206420000000001,46.3,1.4569290770909813,13.725776344947771,4.9251580540702445e-11,0.06926265237447138,164.5129587246859,13.00205098372625,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M430B,Auxin Solar,Mono-c-Si,0,430.0,392.4,1.94,,,54.0,13.744,38.583,12.9905,33.129,0.008246400000000001,-0.10803240000000001,48.5,1.56324066047632,13.746694605110363,2.595295421851154e-10,0.048007222108311896,244.86381756671565,22.71511627899732,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M430W,Auxin Solar,Mono-c-Si,0,430.0,401.1,1.94,,,54.0,13.74,38.58,12.99,33.13,0.0085188,-0.1026228,46.3,1.4044224760329174,13.745954066256054,1.5880348536747824e-11,0.07514784270343361,173.41616927523006,3.0540236468947772,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M435B,Auxin Solar,Mono-c-Si,0,435.0,405.6,1.94,,,54.0,13.76,38.66,13.02,33.4,0.0085312,-0.1028356,46.5,1.4713866704541743,13.763165210474762,5.2703165217372765e-11,0.047122520458218714,204.85395608507093,13.585600635024933,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M435W,Auxin Solar,Mono-c-Si,0,435.0,405.9,1.94,,,54.0,13.76,38.66,13.02,33.4,0.0085312,-0.1028356,46.3,1.4713866704541743,13.763165210474762,5.2703165217372765e-11,0.047122520458218714,204.85395608507093,13.585600635024933,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M440B,Auxin Solar,Mono-c-Si,0,440.0,401.9,1.94,,,54.0,13.90608615,39.62331972,13.19136279,33.37654846,0.008343651689999999,-0.11094529521600001,48.5,1.5862868174098768,13.908892984556884,1.9626273922734114e-10,0.10608682265529044,525.5930207635521,19.83965169517284,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M440W,Auxin Solar,Mono-c-Si,0,440.0,404.3,1.94,,,54.0,13.90608615,39.62331972,13.19136279,33.37654846,0.006953043075,-0.11094529521600001,47.6,1.55682230923132,13.909547324234289,1.2221449570065644e-10,0.110949477849178,445.7657965029794,15.468006967584234,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M445B,Auxin Solar,Mono-c-Si,0,445.0,406.6,1.94,,,54.0,14.02408755,39.68768412,13.3147279,33.44292425,0.00841445253,-0.11112551553600002,48.5,1.5884754984745677,14.02636861037941,1.9691652317062693e-10,0.10442289437508166,641.997858274734,19.78632600938867,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M445W,Auxin Solar,Mono-c-Si,0,445.0,409.1,1.94,,,54.0,14.02408755,39.68768412,13.3147279,33.44292425,0.007012043775000001,-0.11112551553600002,47.6,1.5589716055892153,14.026999759672579,1.226098098328422e-10,0.10924726554185547,526.0930694290405,15.415677202290084,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M450B,Auxin Solar,Mono-c-Si,0,450.0,411.4,1.94,,,54.0,14.14208895,39.75204852,13.438093,33.50930004,0.00848525337,-0.11130573585600002,48.5,1.5906746745571219,14.143854008259325,1.9759085167205635e-10,0.10278649484340197,823.5483086946416,19.734665985564277,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M450W,Auxin Solar,Mono-c-Si,0,450.0,413.8,1.94,,,54.0,14.14208895,39.75204852,13.438093,33.50930004,0.0070710444750000006,-0.11130573585600002,47.6,1.5611311891876,14.144461991568946,1.2301823276757606e-10,0.10757333131678985,641.0809537741638,15.364982758426162,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M455B,Auxin Solar,Mono-c-Si,0,455.0,416.3,2.15,,,60.0,13.17992367,43.58581233,12.43219293,36.63120229,0.0060627648882000005,-0.12116855827740003,49.6,1.6626018621853822,13.188379549288005,5.3527790165629985e-11,0.1449832342133117,225.98100251317817,9.362703590893823,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M455W,Auxin Solar,Mono-c-Si,0,455.0,418.6,1.94,,,54.0,14.26009036,39.81641292,13.5614581,33.57567583,0.00713004518,-0.111485956176,47.6,1.563300754721505,14.261933961726912,1.2343939754092581e-10,0.1059269921621396,819.3356636525951,15.315872529757321,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M460B,Auxin Solar,Mono-c-Si,0,460.0,421.0,2.15,,,60.0,13.28884804,43.6518271,12.54606841,36.69928003,0.0061128700984,-0.12135207933800002,49.6,1.6646754956875824,13.296705000108714,5.364796382235505e-11,0.14296661592674437,241.80619928877374,9.306118271568064,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M460W,Auxin Solar,Mono-c-Si,0,460.0,423.4,1.94,,,54.0,14.37809176,39.88077732,13.6848232,33.64205162,0.007189045880000001,-0.11166617649600001,47.6,1.5654800090787404,14.379415582001165,1.238729555659923e-10,0.10430758651753969,1132.8896740302405,15.268297237937473,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M465B,Auxin Solar,Mono-c-Si,0,465.0,425.8,2.15,,,60.0,13.39550316,43.71646656,12.65757148,36.76593947,0.006161931453599999,-0.12153177703680001,49.6,1.666716860375669,13.402782176205248,5.3771608860022594e-11,0.14102375719041324,259.524661245004,9.252305858605517,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M465W,Auxin Solar,Mono-c-Si,0,465.0,428.2,1.94,,,54.0,14.49382391,39.94390395,13.8058159,33.70715095,0.007246911955000001,-0.11184293106000001,47.6,1.5676264946139156,14.494647266905456,1.2430989505221793e-10,0.1027448662415046,1808.6522930435124,15.223082223432087,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M470B,Auxin Solar,Mono-c-Si,0,470.0,432.1,2.15,,,60.0,13.50215827,43.78110602,12.76907456,36.83259892,0.013502158270000002,-0.11820898625400002,49.6,1.717482852300572,13.507672568262636,1.1359783048708267e-10,0.13072526965162928,320.09032010428234,18.7620572760907,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M470W,Auxin Solar,Mono-c-Si,0,470.0,432.3,2.15,,,60.0,13.50215827,43.78110602,12.76907456,36.83259892,0.0062109928042,-0.12171147473560003,48.5,1.6687687221620027,13.508867688392458,5.390098490391058e-11,0.13911157961310974,279.95073293604946,9.200022125915005,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M475B,Auxin Solar,Mono-c-Si,0,475.0,435.3,2.15,,,60.0,13.60881338,43.84574549,12.88057763,36.89925837,0.0062600541548,-0.1218911724622,49.6,1.6708307852719437,13.614961493575008,5.4035928111200413e-11,0.13722938040498636,303.7564350726368,9.1492217255207,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M475W,Auxin Solar,Mono-c-Si,0,475.0,437.1,2.15,,,60.0,13.60881338,43.84574549,12.88057763,36.89925837,0.0062600541548,-0.1218911724622,48.5,1.6708307852719437,13.614961493575008,5.4035928111200413e-11,0.13722938040498636,303.7564350726368,9.1492217255207,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M480B,Auxin Solar,Mono-c-Si,0,480.0,441.7,2.15,,,60.0,13.7154685,43.91038495,12.9920807,36.96591781,0.013715468500000001,-0.11855803936500002,49.6,1.7217571844426194,13.719930016976287,1.1425210441303078e-10,0.12710951045129032,390.7564567030153,18.65967788028186,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M480W,Auxin Solar,Mono-c-Si,0,480.0,441.8,2.15,,,60.0,13.7154685,43.91038495,12.9920807,36.96591781,0.00630911551,-0.12207087016100002,48.5,1.6729027362711295,13.72106353549364,5.417626032376023e-11,0.13537647938238442,331.8570108521377,9.099857650728733,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M485B,Auxin Solar,Mono-c-Si,0,485.0,446.4,2.15,,,60.0,13.82212361,43.97502441,13.10358378,37.03257726,0.01382212361,-0.11873256590700002,49.6,1.6024874500312687,13.829010711691359,1.652941461943729e-11,0.1458835292937601,292.78211314350057,1.254490781024197,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M485W,Auxin Solar,Mono-c-Si,0,485.0,445.0,2.15,,,60.0,13.82212361,43.97502441,13.10358378,37.03257726,0.005528849444000001,-0.12313006834800001,48.5,1.6937823015658406,13.826737194997186,7.273563310305638e-11,0.1303876203724555,390.6363189430063,10.921561846103188,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M490B,Auxin Solar,Mono-c-Si,0,490.0,451.2,2.15,,,60.0,13.92877873,44.03966387,13.21508685,37.0992367,0.01392877873,-0.11890709244900001,49.6,1.7260700472640484,13.932220208127525,1.1494729333743053e-10,0.12360419144530542,500.26630192679335,18.563021362730765,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M490W,Auxin Solar,Mono-c-Si,0,490.0,449.8,2.15,,,60.0,13.92877873,44.03966387,13.21508685,37.0992367,0.005571511492,-0.12331105883600002,48.5,1.6958925307911714,13.93286751749248,7.293749289397865e-11,0.12861463452271962,438.1359748123152,10.874225969277475,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M495W,Auxin Solar,Mono-c-Si,0,495.0,454.5,2.15,,,60.0,14.03543384,44.10430334,13.32658992,37.16589615,0.0056141735360000005,-0.12349204935200002,48.5,1.6980120846707503,14.039005892094586,7.31460228780549e-11,0.1268685780286136,498.49651049256494,10.828229327844062,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M500W,Auxin Solar,Mono-c-Si,0,500.0,459.3,2.15,,,60.0,14.14208895,44.1689428,13.438093,37.2325556,0.00565683558,-0.12367303984000003,48.5,1.700140713027701,14.145152278108585,7.336105253435642e-11,0.12514885474325269,577.7592951633629,10.783532642140738,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M505W,Auxin Solar,Mono-c-Si,0,505.0,464.1,2.15,,,60.0,14.24874407,44.23358226,13.54959607,37.29921504,0.005699497628000001,-0.123854030328,48.5,1.702278172157804,14.251306634660187,7.35824155803196e-11,0.12345488734508674,686.451824863847,10.74009933533757,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M510W,Auxin Solar,Mono-c-Si,0,510.0,468.8,2.15,,,60.0,14.35312993,44.29684642,13.65872674,37.3644562,0.005741251972,-0.12403116997600001,48.5,1.7043784796538575,14.355210044460746,7.380505025051692e-11,0.1218213600038131,840.5873591152929,10.698779481650567,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M515W,Auxin Solar,Mono-c-Si,0,515.0,473.6,2.15,,,60.0,14.45751578,44.36011057,13.76785741,37.42969736,0.005783006312,-0.12420830959600003,48.5,1.706486801633961,14.459120969221841,7.403345123197339e-11,0.1202114526324768,1082.7129236190292,10.658602726055719,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M520W,Auxin Solar,Mono-c-Si,0,520.0,478.4,2.15,,,60.0,14.56190164,44.42337473,13.87698808,37.49493852,0.005824760656,-0.12438544924400001,48.5,1.708602944143289,14.563039386102492,7.426749417935702e-11,0.11862466645011197,1518.264932651667,10.619539314978013,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M525W,Auxin Solar,Mono-c-Si,0,525.0,483.2,2.15,,,60.0,14.66628749,44.48663889,13.98611874,37.56017968,0.005866514996000001,-0.12456258889200002,48.5,1.7107267073689654,14.666965229376205,7.450704809619299e-11,0.11706051595291886,2533.1911166573623,10.581559557503182,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M530B,Auxin Solar,Mono-c-Si,0,530.0,498.0,2.51,,,72.0,13.71,49.35,12.82,41.35,0.005484,-0.12041400000000001,45.0,1.76734660668398,13.730235291181772,9.963413751884256e-12,0.1888931116754174,127.98059310304447,8.59751553627437,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M530W,Auxin Solar,Mono-c-Si,0,530.0,495.5,2.51,,,72.0,13.71,49.35,12.82,41.35,0.005072699999999999,-0.12436200000000001,46.09,1.779193946109949,13.729789091904102,1.2002837511766405e-11,0.1868032231216064,129.41837889304892,6.777609001801544,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M535B,Auxin Solar,Mono-c-Si,0,535.0,502.8,2.51,,,72.0,13.78,49.5,12.9,41.5,0.005512,-0.12078,45.0,1.772275904121125,13.799170802645637,9.957344947832093e-12,0.18644913799006124,134.01990382563108,8.542009457042687,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M535W,Auxin Solar,Mono-c-Si,0,535.0,500.3,2.51,,,72.0,13.78,49.5,12.9,41.5,0.0050986,-0.12474,46.09,1.7841504308887692,13.79873582975592,1.1994997121693018e-11,0.18436711140636555,135.60001532145372,6.722779843888322,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M540B,Auxin Solar,Mono-c-Si,0,540.0,507.6,2.51,,,72.0,13.85,49.65,12.97,41.65,0.005540000000000001,-0.12114599999999999,45.0,1.7778619830334612,13.868781682881119,1.0045403204743066e-11,0.18396346596879296,135.65845115496438,8.573762981123211,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M540W,Auxin Solar,Mono-c-Si,0,540.0,505.1,2.51,,,72.0,13.85,49.65,12.97,41.65,0.005124500000000001,-0.125118,46.09,1.7897763661177917,13.868350210313718,1.210125855338431e-11,0.18188502027520487,137.2794913310224,6.754054387888008,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M545B,Auxin Solar,Mono-c-Si,0,545.0,512.5,2.51,,,72.0,13.92,49.81,13.04,41.82,0.005568,-0.1215364,45.0,1.7840493677437088,13.938308007463254,1.017211586947476e-11,0.18052377614940127,137.25638752491568,8.638943988909446,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M545W,Auxin Solar,Mono-c-Si,0,545.0,509.9,2.51,,,72.0,13.92,49.81,13.04,41.82,0.005150399999999999,-0.1255212,46.09,1.7960105897443681,13.937881129106378,1.2254334740040719e-11,0.1784472465723857,138.91660108434337,6.81828975821256,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M550W,Auxin Solar,Mono-c-Si,0,550.0,504.6,2.56,,,72.0,13.24346289,52.34918513,12.49862029,44.00509717,0.0045027773826,-0.1408193079997,49.4,1.955996052685564,13.252516318557822,3.108209361435386e-11,0.17976552305512308,262.9631458115137,8.3054648687824,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M555W,Auxin Solar,Mono-c-Si,0,555.0,509.4,2.56,,,72.0,13.3342332,52.4151999,12.59351652,44.0731749,0.0045336392880000005,-0.140996887731,49.4,1.9580392813402936,13.342772815961984,3.114054089317604e-11,0.1777177605518666,277.4984372394945,8.258928586991606,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M560W,Auxin Solar,Mono-c-Si,0,560.0,514.1,2.56,,,72.0,13.42500351,52.48121467,12.68841276,44.14125263,0.0045645011934,-0.1411744674623,49.4,1.9600914706329666,13.433035403893419,3.120146086644066e-11,0.17569780704587334,293.67216990137655,8.213518980002329,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M565W,Auxin Solar,Mono-c-Si,0,565.0,518.9,2.56,,,72.0,13.51577382,52.54722944,12.78330899,44.20933036,0.0045953630988,-0.1413520471936,49.4,1.9621524171905982,13.523304052400626,3.126479784106653e-11,0.17370510956483065,311.77776061290825,8.169209780072853,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M570W,Auxin Solar,Mono-c-Si,0,570.0,523.6,2.56,,,72.0,13.60654413,52.61324421,12.87820522,44.2774081,0.004626225004200001,-0.1415296269249,49.4,1.964221895407444,13.613578722032305,3.1330486577194624e-11,0.1717391338467905,332.1836026168186,8.125970862239955,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M575W,Auxin Solar,Mono-c-Si,0,575.0,528.4,2.56,,,72.0,13.69731444,52.67925898,12.97310146,44.34548583,0.0046570869096,-0.1417072066562,49.4,1.9662997036373815,13.70385937879661,3.1398471445807413e-11,0.16979935836937268,355.35781604859096,8.083775935683594,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M580W,Auxin Solar,Mono-c-Si,0,580.0,533.1,2.56,,,72.0,13.78808475,52.74527376,13.06799769,44.41356356,0.004687948815,-0.1418847864144,49.4,1.9683856464112255,13.79414598928944,3.146869866564463e-11,0.16788527388398417,381.90480542361337,8.042598120238237,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M585W,Auxin Solar,Mono-c-Si,0,585.0,539.4,2.56,,,72.0,13.87431654,52.80798779,13.15814911,44.47823741,0.008324589924,-0.14786236581200002,48.6,2.0282376041830785,13.878776511727365,6.78389701160604e-11,0.1563470600151383,486.3727384278259,10.012289461415936,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M590W,Auxin Solar,Mono-c-Si,0,590.0,544.1,2.56,,,72.0,13.96508685,52.87400256,13.25304534,44.54631514,0.00837905211,-0.14804720716800002,48.6,2.0303949008012347,13.96910048369746,6.800382843610855e-11,0.15454155384800167,537.713828238747,9.973157254182713,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M595W,Auxin Solar,Mono-c-Si,0,595.0,548.9,2.56,,,72.0,14.05131865,52.93671659,13.34319677,44.61098898,0.00843079119,-0.148222806452,48.6,2.032451706128119,14.054913681360643,6.816455977583285e-11,0.15284794116216355,597.412073299737,9.93686069054215,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M600W,Auxin Solar,Mono-c-Si,0,600.0,553.7,2.56,,,72.0,14.1398197,53.00108099,13.43572059,44.67736477,0.00848389182,-0.14840302677200004,48.6,2.034569822577053,14.142990528683253,6.833350378439147e-11,0.1511312764474691,673.9465816926898,9.900466370323036,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M605W,Auxin Solar,Mono-c-Si,0,605.0,558.5,2.56,,,72.0,14.22680791,53.06434515,13.52666282,44.74260593,0.008536084745999999,-0.14858016642000002,48.6,2.0366587829140856,14.22956714802921,6.850350459039537e-11,0.1494647978101361,770.6500887585818,9.86553270112016,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M610W,Auxin Solar,Mono-c-Si,0,610.0,563.3,2.56,,,72.0,14.31417433,53.12788436,13.61800044,44.80813075,0.008588504598,-0.14875807620800002,48.6,2.0387636817759214,14.31652550002561,6.86780795439449e-11,0.14781149724795012,899.8922807878918,9.831262833781075,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M615W,Auxin Solar,Mono-c-Si,0,615.0,568.0,2.56,,,72.0,14.40154076,53.19142358,13.70933806,44.87365557,0.008640924456,-0.14893598602400002,48.6,2.040875270389672,14.403489143837623,6.885639296980858e-11,0.14617830609739088,1080.4816125197908,9.797787917971979,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Auxin Solar AXN10M620W,Auxin Solar,Mono-c-Si,0,620.0,572.8,2.56,,,72.0,14.48890718,53.2549628,13.80067569,44.93918039,0.008693344308,-0.14911389584000004,48.6,2.0429934459468972,14.49045804635206,6.903840538921542e-11,0.14456486092031653,1350.5915936133292,9.765093094743767,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-190M/125-72S,AXITEC,Mono-c-Si,0,190.0,170.6,1.2766400000000002,1.58,0.808,72.0,5.51,45.23,5.21,36.5,0.00453473,-0.1822769,45.8,1.9739738595584153,5.517303455330352,6.175323497155923e-10,0.5814401468837008,999999.9840875501,-2.0989611845304648,-0.4669,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-195M/125-72S,AXITEC,Mono-c-Si,0,195.0,175.2,1.2766400000000002,1.58,0.808,72.0,5.62,45.44,5.28,36.94,0.00462526,-0.18312319999999999,45.8,1.9980190135186784,5.622636438572706,7.408923163101779e-10,0.5114588239166794,1090.259019940889,-0.7683938537760475,-0.4669,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-200M/125-72S,AXITEC,Mono-c-Si,0,200.0,179.8,1.2766400000000002,1.58,0.808,72.0,5.65,45.87,5.35,37.39,0.00464995,-0.18485610000000002,45.8,2.0130901436146162,5.659894530949285,7.194977444118915e-10,0.49193894339426003,999999.9715312029,-1.0773453859622293,-0.4669,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-225P/156-60S,AXITEC,Multi-c-Si,0,225.0,202.3,1.622912,1.636,0.992,60.0,8.08,36.95,7.7,29.22,0.0046056,-0.1289555,45.8,1.5322875839444703,8.080003197954182,2.720909915527511e-10,0.39554843801900735,999998.6691280884,2.9759283479119727,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-230M/156-60S,AXITEC,Mono-c-Si,0,230.0,207.7,1.622912,1.636,0.992,60.0,8.39,37.06,7.8,29.49,0.00577232,-0.13404602000000002,45.7,1.5473412524305914,8.405874873113632,3.2628732899087327e-10,0.39376418216040343,208.10761578733093,0.4093120851588141,-0.4395,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-230P/156-60S,AXITEC,Multi-c-Si,0,230.0,206.9,1.622912,1.636,0.992,60.0,8.23,37.05,7.84,29.34,0.004691100000000001,-0.1293045,45.8,1.5371762894385592,8.230003174716446,2.803860452973158e-10,0.38551457591677235,999999.0522406853,3.0727083580886907,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-235M/156-60S,AXITEC,Mono-c-Si,0,235.0,212.3,1.622912,1.636,0.992,60.0,8.46,37.26,7.87,29.86,0.00582048,-0.13476942,45.7,1.561771503959305,8.474684911277677,3.6111713585253447e-10,0.36080139126788247,207.85826774146383,1.1697302687323692,-0.4395,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-235P/156-60B,AXITEC,Multi-c-Si,0,235.0,210.3,1.622912,1.636,0.992,60.0,8.4,37.3,7.95,29.55,0.0070644,-0.143605,47.9,1.5571714206093912,8.420901510407687,3.3296738130831777e-10,0.40997375160669625,999999.9779468648,-5.810782511842838,-0.4324,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-235P/156-60S,AXITEC,Multi-c-Si,0,235.0,211.5,1.622912,1.636,0.992,60.0,8.32,37.16,7.97,29.49,0.004742400000000001,-0.12968839999999998,45.8,1.5478992955255637,8.320261982504404,3.1186740485961204e-10,0.34557164513668215,10974.68145899009,3.8719099059302478,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-240M/156-60S,AXITEC,Mono-c-Si,0,240.0,217.0,1.622912,1.636,0.992,60.0,8.53,37.47,7.94,30.23,0.0058686400000000005,-0.13552899,45.7,1.5763440188882243,8.543511821741447,3.9730656743317917e-10,0.32975384833577753,208.17331954237181,1.8877097721190763,-0.4395,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-240P/156-60B,AXITEC,Multi-c-Si,0,240.0,214.9,1.622912,1.636,0.992,60.0,8.45,37.4,8.0,30.0,0.0071064499999999985,-0.14399,47.9,1.5721462113148676,8.46296408111015,3.944846360130171e-10,0.3539430860593384,999999.9784689782,-4.545852494783997,-0.4324,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-240P/156-60S,AXITEC,Multi-c-Si,0,240.0,216.1,1.622912,1.636,0.992,60.0,8.48,37.25,8.09,29.67,0.0048336,-0.1300025,45.8,1.5508203598437262,8.480002941393098,3.139338032707148e-10,0.3466524414299198,999998.387781962,3.7664982726074907,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-245M/156-60S,AXITEC,Mono-c-Si,0,245.0,221.6,1.622912,1.636,0.992,60.0,8.6,37.67,8.01,30.59,0.0059168,-0.13625239000000003,45.7,1.5904044322712125,8.61234180009409,4.358229431470996e-10,0.29948589082620874,208.6874693964574,2.58675574027615,-0.4395,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-245P/156-60S,AXITEC,Multi-c-Si,0,245.0,220.8,1.622912,1.636,0.992,60.0,8.63,37.34,8.2,29.88,0.004919100000000001,-0.1303166,45.8,1.5550079689085115,8.630002944534555,3.2166896484221693e-10,0.34098733069194065,999999.9374961347,3.823547591576206,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-250M/156-60S,AXITEC,Mono-c-Si,0,250.0,225.3,1.622912,1.636,0.992,60.0,8.88,37.51,8.22,30.4,0.005772,-0.1211573,47.0,1.5557553133558197,8.899043054969127,2.9189103102857397e-10,0.3047559599951251,142.11129152652887,11.102539286621033,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-250P/156-60S,AXITEC,Multi-c-Si,0,250.0,225.4,1.622912,1.636,0.992,60.0,8.79,37.41,8.34,29.98,0.0050103,-0.13056089999999998,45.8,1.5552382854671485,8.818999963194635,3.1536590355604155e-10,0.34766761228367293,999999.9231062684,3.478820831492844,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-255M/156-60S,AXITEC,Mono-c-Si,0,255.0,229.9,1.622912,1.636,0.992,60.0,9.03,37.59,8.36,30.5,0.0058695,-0.12141570000000003,47.0,1.559998384813383,9.048999746494209,3.011051163312723e-10,0.2953791482784511,140.38471049029914,11.231393120295504,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-255P/156-60S,AXITEC,Multi-c-Si,0,255.0,230.0,1.622912,1.636,0.992,60.0,8.94,37.54,8.43,30.25,0.0050958,-0.1310146,45.8,1.5682208482840498,8.943023471678455,3.576322048236966e-10,0.3208232741426431,948.6319527617884,4.429975558160755,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-260M/156-60S,AXITEC,Mono-c-Si,0,260.0,234.6,1.622912,1.636,0.992,60.0,9.18,37.73,8.5,30.6,0.005967,-0.12186789999999999,47.0,1.5652943703514028,9.199306366151019,3.037579124392238e-10,0.29353323367553535,139.57237000698117,11.161447527300204,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-260P/156-60S,AXITEC,Multi-c-Si,0,260.0,231.5,1.622912,1.636,0.992,60.0,9.09,37.65,8.52,30.51,0.0035451,-0.12801,47.1,1.5989987650824264,9.09769570501392,5.342381496910254e-10,0.28855828165451075,340.83888785193426,10.830175728301262,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-265M/156-60S,AXITEC,Mono-c-Si,0,265.0,239.2,1.622912,1.636,0.992,60.0,9.31,37.91,8.63,30.7,0.0060515000000000005,-0.1224493,47.0,1.5704604960326987,9.328965863668941,2.9781670514875066e-10,0.29719120468229887,145.88580691252028,10.853256372092773,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-265P/156-60S,AXITEC,Multi-c-Si,0,265.0,236.1,1.622912,1.636,0.992,60.0,9.24,37.77,8.61,30.78,0.0036036,-0.12841800000000003,47.1,1.614520831814823,9.251858730924543,6.274037812565626e-10,0.26050740265953887,202.98030175848697,12.154155267906823,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-265P/60S,AXITEC,Multi-c-Si,0,265.0,244.2,1.63,,,60.0,9.1,38.14,8.56,30.96,0.004731999999999999,-0.1140386,44.88,1.4728032192658194,9.109273204617384,5.094356888833969e-11,0.32054162104501055,314.5545657577228,4.215338222189232,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-265P/60V,AXITEC,Multi-c-Si,0,265.0,244.2,1.63,,,60.0,9.1,38.14,8.56,30.96,0.004731999999999999,-0.1140386,44.88,1.4728032192658194,9.109273204617384,5.094356888833969e-11,0.32054162104501055,314.5545657577228,4.215338222189232,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-270M/156-60S,AXITEC,Mono-c-Si,0,270.0,243.9,1.622912,1.636,0.992,60.0,9.39,38.09,8.77,30.79,0.006103500000000001,-0.1230307,47.0,1.569990099345026,9.40282502884688,2.683699210317241e-10,0.30403608935639703,222.60372443707533,9.820565351772794,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-270P/156-60S,AXITEC,Multi-c-Si,0,270.0,244.2,1.6268799999999999,1.64,0.992,60.0,9.31,38.5,8.57,31.11,0.00579082,-0.1358665,45.4,1.6480096756539364,9.333334354743492,6.441185566604787e-10,0.29877110632751225,119.20446778904144,7.966656084260083,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-270P/156-72S,AXITEC,Multi-c-Si,0,270.0,242.8,1.9363839999999999,1.952,0.992,72.0,8.2,44.18,7.7,35.06,0.004673999999999999,-0.1541882,45.8,1.8332692364844276,8.20594058605115,2.7836591511628654e-10,0.49451767754337334,682.6004142380239,3.0632311464139743,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-270P/60S,AXITEC,Multi-c-Si,0,270.0,248.9,1.63,,,60.0,9.15,38.31,8.64,31.26,0.004758,-0.11454690000000001,44.88,1.4807014636586322,9.155894611693256,5.2639849899821697e-11,0.29843792284450166,463.25479368850426,4.432296813033757,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-270P/60V,AXITEC,Multi-c-Si,0,270.0,248.9,1.63,,,60.0,9.15,38.31,8.64,31.26,0.004758,-0.11454690000000001,44.88,1.4807014636586322,9.155894611693256,5.2639849899821697e-11,0.29843792284450166,463.25479368850426,4.432296813033757,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-275P/156-72S,AXITEC,Multi-c-Si,0,275.0,247.4,1.9363839999999999,1.952,0.992,72.0,8.29,44.34,7.81,35.21,0.004725299999999999,-0.15474659999999998,45.8,1.8375081023455289,8.29280697050927,2.737407557375428e-10,0.48727845607221276,1439.1107585273137,2.8225975523044524,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-275P/60S,AXITEC,Multi-c-Si,0,275.0,253.6,1.63,,,60.0,9.24,38.5,8.74,31.46,0.0048048000000000006,-0.115115,44.88,1.4879198993142435,9.244532882502702,5.314164378446097e-11,0.2910722876776117,593.3328510397884,4.423624933559751,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-275P/60V,AXITEC,Multi-c-Si,0,275.0,253.6,1.63,,,60.0,9.24,38.5,8.74,31.46,0.0048048000000000006,-0.115115,44.88,1.4879198993142435,9.244532882502702,5.314164378446097e-11,0.2910722876776117,593.3328510397884,4.423624933559751,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-280M/156-60S,AXITEC,Mono-c-Si,0,280.0,250.7,1.6268799999999999,1.64,0.992,60.0,9.28,39.1,8.91,31.43,0.003712,-0.13685,46.5,1.6611889195282437,9.28022075742648,5.562177980808484e-10,0.2587068481288525,10875.371941083851,7.7721037815683465,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-280M/60S,AXITEC,Mono-c-Si,0,280.0,254.8,1.63,,,60.0,9.36,39.05,8.84,31.68,0.00468,-0.11832149999999998,47.0,1.5362502527066078,9.364916913121915,8.494078902469508e-11,0.3139527449645328,597.6509884630298,6.920548367000131,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-280M/60V,AXITEC,Mono-c-Si,0,280.0,254.8,1.63,,,60.0,9.36,39.05,8.84,31.68,0.00468,-0.11832149999999998,47.0,1.5362502527066078,9.364916913121915,8.494078902469508e-11,0.3139527449645328,597.6509884630298,6.920548367000131,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-280P/156-72S,AXITEC,Multi-c-Si,0,280.0,252.0,1.9363839999999999,1.952,0.992,72.0,8.4,44.46,7.91,35.39,0.004788000000000001,-0.15516539999999998,45.8,1.8454784548197203,8.403451572455333,2.882157757018383e-10,0.46953795055748904,1142.7027232331825,3.143811604867677,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-285M/156-60S,AXITEC,Mono-c-Si,0,285.0,260.7,1.6268799999999999,1.64,0.992,60.0,9.56,38.9,9.05,31.5,0.0053536,-0.121368,45.3,1.5582195869691722,9.561877952432882,1.3725022024966435e-10,0.3065319053983362,1560.446345068289,7.638156447761233,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-285M/156-72S,AXITEC,Mono-c-Si,0,285.0,258.0,1.9403519999999999,1.956,0.992,72.0,8.48,44.78,7.91,36.03,0.005724000000000001,-0.15950636,45.8,1.860457670612137,8.492526678066904,2.93523312483207e-10,0.41593496919351064,281.56936628744234,1.0274965184166254,-0.4316,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-285M/60S,AXITEC,Mono-c-Si,0,285.0,259.4,1.63,,,60.0,9.43,39.24,8.96,31.81,0.0047150000000000004,-0.11889720000000001,47.0,1.5389330196895763,9.435887006624174,7.962685333835707e-11,0.31617803647890713,999999.928277665,6.275026190420218,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-285M/60V,AXITEC,Mono-c-Si,0,285.0,259.4,1.63,,,60.0,9.43,39.24,8.96,31.81,0.0047150000000000004,-0.11889720000000001,47.0,1.5389330196895763,9.435887006624174,7.962685333835707e-11,0.31617803647890713,999999.928277665,6.275026190420218,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-285P/156-72S,AXITEC,Multi-c-Si,0,285.0,256.6,1.9363839999999999,1.952,0.992,72.0,8.52,44.51,8.0,35.6,0.0048564,-0.15533989999999998,45.8,1.8554752924720341,8.52640473707637,3.227031948069347e-10,0.43832289415956177,583.0859617594045,3.9817968646951107,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-290M/156-60S,AXITEC,Mono-c-Si,0,290.0,265.4,1.6268799999999999,1.64,0.992,60.0,9.65,39.2,9.12,31.8,0.005404,-0.12230400000000001,45.3,1.573108709389574,9.653506339252823,1.446877175774973e-10,0.2986502495689944,821.9328830615278,8.022625231249364,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-290M/156-72S,AXITEC,Mono-c-Si,0,290.0,262.6,1.9403519999999999,1.956,0.992,72.0,8.55,44.98,7.97,36.4,0.005771250000000001,-0.16021876,45.8,1.875817546313814,8.56257810488263,3.2349293951620026e-10,0.38330789611409005,260.5545860497623,1.7617096382574151,-0.4316,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-290M/60S,AXITEC,Mono-c-Si,0,290.0,264.1,1.63,,,60.0,9.54,39.42,9.06,32.01,0.00477,-0.11944260000000001,47.0,1.547348984584386,9.540032724260245,8.232227159675549e-11,0.30719390056886847,89556.22769336347,6.466089993567402,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-290M/60V,AXITEC,Mono-c-Si,0,290.0,264.1,1.63,,,60.0,9.54,39.42,9.06,32.01,0.00477,-0.11944260000000001,47.0,1.547348984584386,9.540032724260245,8.232227159675549e-11,0.30719390056886847,89556.22769336347,6.466089993567402,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-290P/156-72S,AXITEC,Multi-c-Si,0,290.0,261.2,1.9363839999999999,1.952,0.992,72.0,8.64,44.65,8.09,35.86,0.0049248,-0.15582849999999998,45.8,1.8685663697483175,8.648987142264481,3.578149986767413e-10,0.4118982861411247,395.98816815148007,4.7456082984046715,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-295M/156-72S,AXITEC,Mono-c-Si,0,295.0,265.8,1.9363839999999999,1.952,0.992,72.0,8.71,45.01,8.09,36.48,0.005661500000000001,-0.1453823,47.0,1.8634840173984721,8.726009793098804,2.7530895842579276e-10,0.3729099089964329,202.87867248468277,10.73930041145585,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-295M/60S,AXITEC,Mono-c-Si,0,295.0,268.8,1.63,,,60.0,9.67,39.56,9.15,32.25,0.004835000000000001,-0.1198668,47.0,1.5589528682199583,9.673495659580515,9.176732857767916e-11,0.2879747068698594,796.6208139986032,7.3010032587569675,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-295M/60V,AXITEC,Mono-c-Si,0,295.0,268.8,1.63,,,60.0,9.67,39.56,9.15,32.25,0.004835000000000001,-0.1198668,47.0,1.5589528682199583,9.673495659580515,9.176732857767916e-11,0.2879747068698594,796.6208139986032,7.3010032587569675,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-295P/156-72S,AXITEC,Multi-c-Si,0,295.0,265.9,1.9363839999999999,1.952,0.992,72.0,8.76,44.74,8.2,35.98,0.0049932,-0.1561426,45.8,1.8740733416003528,8.769314647122417,3.7073920182643905e-10,0.4001753938202814,376.34675489477945,4.930803299618735,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-300M/156-72S,AXITEC,Mono-c-Si,0,300.0,270.4,1.9363839999999999,1.952,0.992,72.0,8.81,45.11,8.2,36.6,0.005726500000000001,-0.1457053,47.0,1.8666876223750162,8.824372235528921,2.757698112673273e-10,0.3640800825596093,223.17653698904246,10.645091425547662,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-300M/60S,AXITEC,Mono-c-Si,0,300.0,273.5,1.6268799999999999,,,60.0,9.74,39.72,9.27,32.37,0.00487,-0.12035159999999999,47.0,1.5631329860999594,9.740002744474497,8.972527621019073e-11,0.2817292808906808,999999.9620987818,7.028261245028753,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-300M/60V,AXITEC,Mono-c-Si,0,300.0,273.4,1.6268799999999999,,,60.0,9.74,39.72,9.27,32.37,0.00487,-0.12035159999999999,47.07,1.5631329860999594,9.740002744474497,8.972527621019073e-11,0.2817292808906808,999999.9620987818,7.028261245028753,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-300P/156-72S,AXITEC,Multi-c-Si,0,300.0,270.5,1.9363839999999999,1.952,0.992,72.0,8.88,44.82,8.26,36.3,0.0050616,-0.15642179999999997,45.8,1.8916712229963606,8.894090384220819,4.460870913814401e-10,0.35846799320155737,225.91266296186913,6.419125195002418,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-305M/156-72S,AXITEC,Mono-c-Si,0,305.0,275.0,1.9363839999999999,1.952,0.992,72.0,8.92,45.28,8.31,36.72,0.005798,-0.1462544,47.0,1.8722851757641639,8.93388978077904,2.7439717655488374e-10,0.3635717301631838,233.48533592692283,10.486054199428667,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-305M/60S,AXITEC,Mono-c-Si,0,305.0,278.1,1.6268799999999999,,,60.0,9.83,39.81,9.41,32.41,0.004915,-0.1206243,47.07,1.570056756238012,9.830002559326411,9.564897556482799e-11,0.26031787822539093,999996.4042476001,7.501373606183403,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-305M/60V,AXITEC,Mono-c-Si,0,305.0,278.1,1.6268799999999999,,,60.0,9.83,39.81,9.41,32.41,0.004915,-0.1206243,47.07,1.570056756238012,9.830002559326411,9.564897556482799e-11,0.26031787822539093,999996.4042476001,7.501373606183403,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-305MH/120S,AXITEC,Mono-c-Si,0,305.0,283.3,1.6616,,,60.0,9.86,39.42,9.42,32.37,0.0041412,-0.1119528,44.64,1.4757361318123727,9.860002576220792,2.4715018308311808e-11,0.2612680402529588,999999.6651622022,2.9465801627533104,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-305MH/120V,AXITEC,Mono-c-Si,0,305.0,283.3,1.6616,,,60.0,9.86,39.42,9.42,32.37,0.0041412,-0.1119528,44.64,1.4757361318123727,9.860002576220792,2.4715018308311808e-11,0.2612680402529588,999999.6651622022,2.9465801627533104,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-305P/156-72S,AXITEC,Multi-c-Si,0,305.0,275.1,1.9363839999999999,1.952,0.992,72.0,8.99,44.91,8.33,36.61,0.005124300000000001,-0.15673589999999998,45.8,1.9068414719654063,9.006045685691642,5.173564677653971e-10,0.32066341002275345,179.6597812576409,7.61139552751991,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-310M/156-72S,AXITEC,Mono-c-Si,0,310.0,279.7,1.9363839999999999,1.952,0.992,72.0,9.01,45.49,8.41,36.84,0.005856500000000001,-0.1469327,47.0,1.8775887873788821,9.022623163924175,2.66010635569896e-10,0.3688194220511075,263.2512153494445,10.112250664272233,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-310M/60S,AXITEC,Mono-c-Si,0,310.0,282.9,1.6268799999999999,,,60.0,9.92,39.9,9.55,32.46,0.00496,-0.120897,47.07,1.577586086442789,9.92021104806002,1.0286579222353378e-10,0.23451274890134766,11022.940684168607,8.055108715358969,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-310M/60V,AXITEC,Mono-c-Si,0,310.0,282.9,1.6268799999999999,,,60.0,9.92,39.9,9.55,32.46,0.00496,-0.120897,47.07,1.577586086442789,9.92021104806002,1.0286579222353378e-10,0.23451274890134766,11022.940684168607,8.055108715358969,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-310MH/120S,AXITEC,Mono-c-Si,0,310.0,288.0,1.6616,,,60.0,9.95,39.58,9.51,32.58,0.0041789999999999996,-0.11240719999999998,44.64,1.4835524970474712,9.950002483279949,2.5774502952577703e-11,0.24956454304756076,999999.6224476228,3.220611373794231,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-310MH/120V,AXITEC,Mono-c-Si,0,310.0,288.0,1.6616,,,60.0,9.95,39.58,9.51,32.58,0.0041789999999999996,-0.11240719999999998,44.64,1.4835524970474712,9.950002483279949,2.5774502952577703e-11,0.24956454304756076,999999.6224476228,3.220611373794231,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-310P/156-72S,AXITEC,Multi-c-Si,0,310.0,276.0,1.9363839999999999,1.952,0.992,72.0,9.1,45.05,8.42,36.82,0.003549,-0.15317,47.1,1.9366211480913575,9.116068296387642,6.987599612555589e-10,0.2993036875311677,169.5054569611786,13.302242125915415,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-315M/156-72S,AXITEC,Mono-c-Si,0,315.0,284.3,1.9363839999999999,1.952,0.992,72.0,9.12,45.62,8.53,36.91,0.005927999999999999,-0.1473526,47.0,1.8799170812193982,9.131147844723875,2.595790277245183e-10,0.37043024133281166,303.0472957298873,9.77916706552408,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-315MH/120S,AXITEC,Mono-c-Si,0,315.0,292.8,1.6616,,,60.0,10.04,39.74,9.6,32.79,0.0042168,-0.11286159999999999,44.64,1.4913668436071283,10.040002390421462,2.6866973372054903e-11,0.23807905771272106,999999.5721261625,3.4921381327768453,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-315MH/120V,AXITEC,Mono-c-Si,0,315.0,292.8,1.6616,,,60.0,10.04,39.74,9.6,32.79,0.0042168,-0.11286159999999999,44.64,1.4913668436071283,10.040002390421462,2.6866973372054903e-11,0.23807905771272106,999999.5721261625,3.4921381327768453,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-315P/156-72S,AXITEC,Multi-c-Si,0,315.0,280.6,1.9363839999999999,1.952,0.992,72.0,9.21,45.16,8.49,37.11,0.0035919000000000007,-0.153544,47.1,1.9517472744270639,9.227236722617803,7.964308312196451e-10,0.26782248144568577,143.10408063973796,14.412416519176084,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-315P/72S,AXITEC,Multi-c-Si,0,315.0,290.3,1.93,,,72.0,8.91,45.6,8.45,37.28,0.0046332,-0.136344,44.88,1.7604999561297903,8.912329324078016,5.0046368082205825e-11,0.35512143992302075,1358.3907103485228,4.214516323878748,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-315P/72V,AXITEC,Multi-c-Si,0,315.0,290.3,1.93,,,72.0,8.91,45.6,8.45,37.28,0.0046332,-0.136344,44.88,1.7604999561297903,8.912329324078016,5.0046368082205825e-11,0.35512143992302075,1358.3907103485228,4.214516323878748,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-320MH/120S,AXITEC,Mono-c-Si,0,320.0,297.6,1.6616,,,60.0,10.13,39.92,9.69,33.01,0.004254600000000001,-0.1133728,44.64,1.4998013110853112,10.13000230605689,2.79288369602492e-11,0.22763609561859946,999999.5197483771,3.7419525564327647,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-320MH/120V,AXITEC,Mono-c-Si,0,320.0,297.6,1.6616,,,60.0,10.13,39.92,9.69,33.01,0.004254600000000001,-0.1133728,44.64,1.4998013110853112,10.13000230605689,2.79288369602492e-11,0.22763609561859946,999999.5197483771,3.7419525564327647,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-320P/156-72S,AXITEC,Multi-c-Si,0,320.0,285.2,1.9363839999999999,1.952,0.992,72.0,9.32,45.27,8.57,37.34,0.0036348,-0.15391800000000003,47.1,1.9637136206291297,9.33770580029894,8.744315657467687e-10,0.24543702178238191,129.19344246230148,15.180991787959066,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-320P/72S,AXITEC,Multi-c-Si,0,320.0,295.0,1.93,,,72.0,9.03,45.82,8.52,37.56,0.004695599999999999,-0.1370018,44.88,1.776027857992175,9.036316406220767,5.5845246857735406e-11,0.338182312698678,483.46896673551686,5.048273003050337,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-320P/72V,AXITEC,Multi-c-Si,0,320.0,295.0,1.93,,,72.0,9.03,45.82,8.52,37.56,0.004695599999999999,-0.1370018,44.88,1.776027857992175,9.036316406220767,5.5845246857735406e-11,0.338182312698678,483.46896673551686,5.048273003050337,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-320P/72X,AXITEC,Multi-c-Si,0,320.0,290.2,1.93,,,72.0,9.03,45.82,8.52,37.56,0.0046053,-0.146624,47.07,1.83580614707404,9.03497594934602,1.2959037497043484e-10,0.3232232516099398,586.5626158240118,5.004055435634687,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-320P/72XV,AXITEC,Multi-c-Si,0,320.0,290.2,1.93,,,72.0,9.03,45.82,8.52,37.56,0.0046053,-0.146624,47.07,1.83580614707404,9.03497594934602,1.2959037497043484e-10,0.3232232516099398,586.5626158240118,5.004055435634687,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325MH/120S,AXITEC,Mono-c-Si,0,325.0,303.7,1.66,,,60.0,10.43,40.1,9.93,32.71,0.0044849,-0.10706700000000001,44.37,1.4641920534659896,10.431193635511852,1.3292498939862344e-11,0.2926780896806768,2557.424479442638,3.690510871845417,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325MH/120V,AXITEC,Mono-c-Si,0,325.0,303.7,1.66,,,60.0,10.43,40.1,9.93,32.71,0.0044849,-0.10706700000000001,44.37,1.4641920534659896,10.431193635511852,1.3292498939862344e-11,0.2926780896806768,2557.424479442638,3.690510871845417,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325P/156-72S,AXITEC,Multi-c-Si,0,325.0,295.5,1.9404,1.96,0.99,72.0,9.22,45.7,8.7,37.4,0.0053844800000000005,-0.1632404,43.2,1.9956783415520971,9.221701953055899,1.043019548350295e-09,0.28423083988358316,1539.7679126519502,10.953587442465322,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325P/72S,AXITEC,Multi-c-Si,0,325.0,299.8,1.93,,,72.0,9.15,45.92,8.63,37.66,0.004758,-0.1373008,44.88,1.7806939510002961,9.156665385211673,5.7210659945507146e-11,0.33202237442082083,455.788337331015,5.1428024601971964,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325P/72V,AXITEC,Multi-c-Si,0,325.0,299.8,1.93,,,72.0,9.15,45.92,8.63,37.66,0.004758,-0.1373008,44.88,1.7806939510002961,9.156665385211673,5.7210659945507146e-11,0.33202237442082083,455.788337331015,5.1428024601971964,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325P/72X,AXITEC,Multi-c-Si,0,325.0,294.9,1.93,,,72.0,9.15,45.92,8.63,37.66,0.0046665000000000005,-0.14694400000000002,47.07,1.840655497541709,9.155302665291313,1.3275619589920382e-10,0.3172021780022104,547.347427805768,5.098193302020491,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-325P/72XV,AXITEC,Multi-c-Si,0,325.0,294.9,1.93,,,72.0,9.15,45.92,8.63,37.66,0.0046665000000000005,-0.14694400000000002,47.07,1.840655497541709,9.155302665291313,1.3275619589920382e-10,0.3172021780022104,547.347427805768,5.098193302020491,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330MH/120S,AXITEC,Mono-c-Si,0,330.0,308.5,1.66,,,60.0,10.51,40.27,10.02,32.91,0.0045192999999999995,-0.10752090000000002,44.37,1.470880819353742,10.51000416387591,1.3533802473860157e-11,0.28460287451973065,718378.9446036828,3.772649156976001,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330MH/120V,AXITEC,Mono-c-Si,0,330.0,308.5,1.66,,,60.0,10.51,40.27,10.02,32.91,0.0045192999999999995,-0.10752090000000002,44.37,1.470880819353742,10.51000416387591,1.3533802473860157e-11,0.28460287451973065,718378.9446036828,3.772649156976001,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330P/156-72S,AXITEC,Multi-c-Si,0,330.0,300.2,1.9404,1.96,0.99,72.0,9.27,45.9,8.76,37.7,0.00541368,-0.1639548,43.2,2.0070868311259904,9.270894621985812,1.0826161824213531e-09,0.265764400598127,2753.83706779974,11.236862487070029,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330P/72S,AXITEC,Multi-c-Si,0,330.0,304.5,1.93,,,72.0,9.28,45.97,8.73,37.8,0.004825599999999999,-0.1374503,44.88,1.7874734287822585,9.288535353072229,6.201343243302059e-11,0.31435689259129057,341.78223507082436,5.719597613147642,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330P/72V,AXITEC,Multi-c-Si,0,330.0,304.5,1.93,,,72.0,9.28,45.97,8.73,37.8,0.004825599999999999,-0.1374503,44.88,1.7874734287822585,9.288535353072229,6.201343243302059e-11,0.31435689259129057,341.78223507082436,5.719597613147642,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330P/72X,AXITEC,Multi-c-Si,0,330.0,299.5,1.93,,,72.0,9.28,45.97,8.73,37.8,0.0047328,-0.147104,47.07,1.8478245055647644,9.287109440315051,1.4388374889399586e-10,0.299573960189114,391.03591813004255,5.672643185881288,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-330P/72XV,AXITEC,Multi-c-Si,0,330.0,299.5,1.93,,,72.0,9.28,45.97,8.73,37.8,0.0047328,-0.147104,47.07,1.8478245055647644,9.287109440315051,1.4388374889399586e-10,0.299573960189114,391.03591813004255,5.672643185881288,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335M/72S,AXITEC,Mono-c-Si,0,335.0,304.9,1.93,,,72.0,9.41,46.04,8.95,37.44,0.004705000000000001,-0.1395012,47.0,1.8095298696424869,9.410004020503697,8.390757901596156e-11,0.3562087233472419,833801.0292632509,6.747726133312224,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335M/72V,AXITEC,Mono-c-Si,0,335.0,304.9,1.93,,,72.0,9.41,46.04,8.95,37.44,0.004705000000000001,-0.1395012,47.0,1.8095298696424869,9.410004020503697,8.390757901596156e-11,0.3562087233472419,833801.0292632509,6.747726133312224,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335MH/120S,AXITEC,Mono-c-Si,0,335.0,313.3,1.66,,,60.0,10.6,40.44,10.11,33.11,0.0045579999999999996,-0.1079748,44.37,1.4784941511361318,10.600004153902342,1.4009223065402097e-11,0.2763610713413967,705236.8329791877,3.9919998454327286,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335MH/120V,AXITEC,Mono-c-Si,0,335.0,313.3,1.66,,,60.0,10.6,40.44,10.11,33.11,0.0045579999999999996,-0.1079748,44.37,1.4784941511361318,10.600004153902342,1.4009223065402097e-11,0.2763610713413967,705236.8329791877,3.9919998454327286,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335P/156-72S,AXITEC,Multi-c-Si,0,335.0,304.9,1.9404,1.96,0.99,72.0,9.34,46.2,8.82,38.0,0.00545456,-0.16502640000000002,43.2,2.0226499915051366,9.341386338778982,1.1202489017492682e-09,0.25817147672610685,1739.3483413307094,11.481040772886267,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335P/72S,AXITEC,Multi-c-Si,0,335.0,309.2,1.93,,,72.0,9.3,46.45,8.82,37.98,0.004836000000000001,-0.1388855,44.88,1.7934309047194554,9.302423670724652,5.232368327816921e-11,0.3459020269394099,1327.2798011130783,4.228460105040065,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335P/72V,AXITEC,Multi-c-Si,0,335.0,309.2,1.93,,,72.0,9.3,46.45,8.82,37.98,0.004836000000000001,-0.1388855,44.88,1.7934309047194554,9.302423670724652,5.232368327816921e-11,0.3459020269394099,1327.2798011130783,4.228460105040065,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335P/72X,AXITEC,Multi-c-Si,0,335.0,304.2,1.93,,,72.0,9.3,46.45,8.82,37.98,0.004743000000000001,-0.14864000000000002,47.07,1.853561893098612,9.301170671277504,1.21437965874355e-10,0.3314102866941798,2632.777528734941,4.18781122481426,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-335P/72XV,AXITEC,Multi-c-Si,0,335.0,304.2,1.93,,,72.0,9.3,46.45,8.82,37.98,0.004743000000000001,-0.14864000000000002,47.07,1.853561893098612,9.301170671277504,1.21437965874355e-10,0.3314102866941798,2632.777528734941,4.18781122481426,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-340M/156-72S,AXITEC,Mono-c-Si,0,340.0,310.6,1.9403519999999999,1.956,0.992,72.0,9.45,46.6,8.93,38.1,0.0046305,-0.14772200000000002,45.2,1.8836402059304977,9.453584937981148,1.6940048847400303e-10,0.3223667874414071,849.7682468254563,7.936149282702485,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-340M/72S,AXITEC,Mono-c-Si,0,340.0,309.6,1.93,,,72.0,9.48,46.16,9.05,37.57,0.004740000000000001,-0.13986479999999998,47.0,1.8180138771748724,9.480003107804242,8.910858183661567e-11,0.3277847961363803,999999.6638161311,7.202282220236277,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-340M/72V,AXITEC,Mono-c-Si,0,340.0,309.6,1.93,,,72.0,9.48,46.16,9.05,37.57,0.004740000000000001,-0.13986479999999998,47.0,1.8180138771748724,9.480003107804242,8.910858183661567e-11,0.3277847961363803,999999.6638161311,7.202282220236277,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-340MH/120S,AXITEC,Mono-c-Si,0,340.0,318.1,1.66,,,60.0,10.69,40.62,10.21,33.31,0.0045967,-0.10845540000000001,44.37,1.4869427132896809,10.690002822313032,1.4622022197448026e-11,0.2640064641215188,999999.7155066212,4.28251807048531,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-340MH/120V,AXITEC,Mono-c-Si,0,340.0,318.1,1.66,,,60.0,10.69,40.62,10.21,33.31,0.0045967,-0.10845540000000001,44.37,1.4869427132896809,10.690002822313032,1.4622022197448026e-11,0.2640064641215188,999999.7155066212,4.28251807048531,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-340P/156-72S,AXITEC,Multi-c-Si,0,340.0,309.6,1.9404,1.96,0.99,72.0,9.4,46.4,8.89,38.3,0.0054896,-0.1657408,43.2,2.033959124356235,9.400626871167876,1.1618552590330547e-09,0.2399122660920528,3597.5235435829613,11.749317240902505,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-340P/72X,AXITEC,Multi-c-Si,0,340.0,308.9,1.93,,,72.0,9.4,46.61,8.91,38.16,0.004794,-0.149152,47.07,1.861780135962948,9.401668473426835,1.2571238979887553e-10,0.3225296201519543,1817.0977592583076,4.391126663002541,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-340P/72XV,AXITEC,Multi-c-Si,0,340.0,308.9,1.93,,,72.0,9.4,46.61,8.91,38.16,0.004794,-0.149152,47.07,1.861780135962948,9.401668473426835,1.2571238979887553e-10,0.3225296201519543,1817.0977592583076,4.391126663002541,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-345M/156-72S,AXITEC,Mono-c-Si,0,345.0,315.3,1.9403519999999999,1.956,0.992,72.0,9.5,47.0,8.99,38.4,0.004655,-0.14899,45.2,1.8976878841097022,9.502469938017079,1.6594430993191685e-10,0.3270675091707228,1257.9838754551217,7.705478207962873,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-345M/72S,AXITEC,Mono-c-Si,0,345.0,314.3,1.93,,,72.0,9.51,46.61,9.09,37.96,0.0047550000000000005,-0.1412283,47.0,1.8372954271636148,9.51000305297369,9.133642371196736e-11,0.3209864700457575,999999.1576346605,7.388473000060011,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-345M/72V,AXITEC,Mono-c-Si,0,345.0,314.3,1.93,,,72.0,9.51,46.61,9.09,37.96,0.0047550000000000005,-0.1412283,47.0,1.8372954271636148,9.51000305297369,9.133642371196736e-11,0.3209864700457575,999999.1576346605,7.388473000060011,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-345P/156-72S,AXITEC,Multi-c-Si,0,345.0,314.3,1.9404,1.96,0.99,72.0,9.46,46.6,8.95,38.6,0.005524640000000001,-0.16645520000000003,43.2,2.046518711633191,9.460562336752412,1.2198162670779127e-09,0.2216824696721912,3729.282269641433,12.134187597590122,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-345P/72X,AXITEC,Multi-c-Si,0,345.0,313.6,1.93,,,72.0,9.5,46.76,8.98,38.42,0.0048449999999999995,-0.14963200000000001,47.07,1.8741037953165143,9.503839378044242,1.3776101143342498e-10,0.302084946636624,747.4666449509654,5.085933765371945,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-345P/72XV,AXITEC,Multi-c-Si,0,345.0,313.6,1.93,,,72.0,9.5,46.76,8.98,38.42,0.0048449999999999995,-0.14963200000000001,47.07,1.8741037953165143,9.503839378044242,1.3776101143342498e-10,0.302084946636624,747.4666449509654,5.085933765371945,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-350M/156-72S,AXITEC,Mono-c-Si,0,350.0,320.0,1.9403519999999999,1.956,0.992,72.0,9.59,47.2,9.1,38.5,0.0046991,-0.149624,45.2,1.9013870075685095,9.590183823911381,1.587760637137247e-10,0.33374488603305874,17411.362635073885,7.230328645046754,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-350M/72S,AXITEC,Mono-c-Si,0,350.0,319.0,1.93,,,72.0,9.58,46.89,9.13,38.34,0.00479,-0.1420767,47.0,1.8491851582670515,9.580003037763737,9.309118687495617e-11,0.31705374036963424,999999.9355668632,7.4897333613520685,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-350M/72V,AXITEC,Mono-c-Si,0,350.0,319.0,1.93,,,72.0,9.58,46.89,9.13,38.34,0.00479,-0.1420767,47.0,1.8491851582670515,9.580003037763737,9.309118687495617e-11,0.31705374036963424,999999.9355668632,7.4897333613520685,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-350MH/120V,AXITEC,Mono-c-Si,0,350.0,322.7,1.81,,,60.0,11.15,40.1,10.42,33.6,0.0061771,-0.11171860000000002,46.0,1.573145351198383,11.16207484717893,9.261981486923336e-11,0.15942448526437147,147.2137090373453,15.52492285440527,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-350MH/120VB,AXITEC,Mono-c-Si,0,350.0,326.4,1.81,,,60.0,11.15,40.1,10.42,33.6,0.0059095,-0.11268100000000002,44.2,1.5358103603622737,11.163295031603257,4.9785459819574983e-11,0.1673037797584847,140.31084818128528,8.965951742959888,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-355M/156-72S,AXITEC,Mono-c-Si,0,355.0,324.7,1.9403519999999999,1.956,0.992,72.0,9.67,47.4,9.2,38.6,0.004738300000000001,-0.150258,45.2,1.9099074439993542,9.670003179384697,1.611101481933159e-10,0.32871686844187165,999999.975643722,7.283771984416955,-0.425,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-355M/72S,AXITEC,Mono-c-Si,0,355.0,323.7,1.93,,,72.0,9.66,47.16,9.19,38.63,0.004830000000000001,-0.1428948,47.0,1.8598357756768513,9.660004016920853,9.387191883667834e-11,0.3202081248760659,770122.121540405,7.490047282802134,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-355M/72V,AXITEC,Mono-c-Si,0,355.0,323.7,1.93,,,72.0,9.66,47.16,9.19,38.63,0.004830000000000001,-0.1428948,47.0,1.8598357756768513,9.660004016920853,9.387191883667834e-11,0.3202081248760659,770122.121540405,7.490047282802134,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-355MH/120V,AXITEC,Mono-c-Si,0,355.0,327.5,1.81,,,60.0,11.25,40.3,10.51,33.8,0.0062325,-0.1122758,46.0,1.5820674121480922,11.262132755583469,9.503872526927639e-11,0.15517143889465929,143.88147054481757,15.684015933070386,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-355MH/120VB,AXITEC,Mono-c-Si,0,355.0,331.2,1.81,,,60.0,11.25,40.3,10.51,33.8,0.0059625,-0.113243,44.2,1.5445127757747685,11.263361144128975,5.1100556853290356e-11,0.16303521403095028,137.27463427753585,9.118826409166019,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-355MH/144S,AXITEC,Mono-c-Si,0,355.0,328.9,1.984,,,72.0,9.6,46.82,9.1,39.01,0.004032,-0.128755,45.81,1.7400083007077474,9.604622302528583,1.9618611623175567e-11,0.26581165055952405,552.0607674568946,4.624316902547036,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-355MH/144V,AXITEC,Mono-c-Si,0,355.0,328.9,1.984,,,72.0,9.6,46.82,9.1,39.01,0.004032,-0.128755,45.81,1.7400083007077474,9.604622302528583,1.9618611623175567e-11,0.26581165055952405,552.0607674568946,4.624316902547036,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-360M/72S,AXITEC,Mono-c-Si,0,360.0,328.3,1.940352,,,72.0,9.73,47.44,9.23,39.01,0.004865000000000001,-0.1437432,47.0,1.8718014930870162,9.730006613088065,9.574197678767187e-11,0.30177832287751927,444038.34046361217,7.598432427777016,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-360M/72V,AXITEC,Mono-c-Si,0,360.0,328.3,1.940352,,,72.0,9.73,47.44,9.23,39.01,0.004865000000000001,-0.1437432,47.0,1.8718014930870162,9.730006613088065,9.574197678767187e-11,0.30177832287751927,444038.34046361217,7.598432427777016,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-360MH/120V,AXITEC,Mono-c-Si,0,360.0,332.2,1.81,,,60.0,11.35,40.5,10.59,34.0,0.0062879,-0.11283300000000002,46.0,1.591767334203999,11.36271125514716,9.860490354710674e-11,0.15083926337318254,134.68580758691422,15.951533243766043,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-360MH/120VB,AXITEC,Mono-c-Si,0,360.0,336.0,1.81,,,60.0,11.35,40.5,10.59,34.0,0.0060155,-0.11380500000000002,44.2,1.5539682011737326,11.363976164781905,5.304380624766523e-11,0.15870209830678145,128.88148207493782,9.375810810236858,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-360MH/144S,AXITEC,Mono-c-Si,0,360.0,333.7,1.984,,,72.0,9.69,47.01,9.18,39.2,0.0040698,-0.1292775,45.81,1.748279007225648,9.69500271421753,2.0159388185385154e-11,0.2603784075469799,504.33958293467464,4.7784625000705345,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-360MH/144V,AXITEC,Mono-c-Si,0,360.0,333.7,1.984,,,72.0,9.69,47.01,9.18,39.2,0.0040698,-0.1292775,45.81,1.748279007225648,9.69500271421753,2.0159388185385154e-11,0.2603784075469799,504.33958293467464,4.7784625000705345,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-365M/72S,AXITEC,Mono-c-Si,0,365.0,333.1,1.93,,,72.0,9.81,47.67,9.27,39.38,0.0049050000000000005,-0.1444401,47.0,1.8933765229582198,9.81459917400364,1.1322643629767292e-10,0.27682366164961203,590.4625653690158,9.017506444882276,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-365M/72V,AXITEC,Mono-c-Si,0,365.0,333.1,1.93,,,72.0,9.81,47.67,9.27,39.38,0.0049050000000000005,-0.1444401,47.0,1.8933765229582198,9.81459917400364,1.1322643629767292e-10,0.27682366164961203,590.4625653690158,9.017506444882276,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-365MH/120V,AXITEC,Mono-c-Si,0,365.0,337.0,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0063322199999999995,-0.11339020000000001,46.0,1.5992338744726025,11.441735753316635,9.883882152273302e-11,0.14727260206241186,143.43568615318978,15.902164143097854,-0.3798,N,2025.7.3,6/23/2025,4.0,bootstrapping +AXITEC AC-365MH/120VB,AXITEC,Mono-c-Si,0,365.0,340.8,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0060579,-0.11436700000000002,44.2,1.5612619148644942,11.442953832404886,5.316537385698562e-11,0.15510751240870377,136.8613415831665,9.328389567386376,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-365MH/144S,AXITEC,Mono-c-Si,0,365.0,338.4,1.984,,,72.0,9.77,47.21,9.27,39.39,0.0041034,-0.1298275,45.81,1.7549399331946522,9.774040912686413,2.0120328574923806e-11,0.2566389574945642,620.494139604135,4.685933416029039,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-365MH/144V,AXITEC,Mono-c-Si,0,365.0,338.4,1.984,,,72.0,9.77,47.21,9.27,39.39,0.0041034,-0.1298275,45.81,1.7549399331946522,9.774040912686413,2.0120328574923806e-11,0.2566389574945642,620.494139604135,4.685933416029039,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-370M/72S,AXITEC,Mono-c-Si,0,370.0,337.7,1.940352,,,72.0,9.89,47.91,9.29,39.84,0.004945000000000001,-0.1451673,47.0,1.9156530254176194,9.898028879978085,1.3392260951513716e-10,0.24235941283846782,298.53911121533275,10.45680351073249,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-370M/72V,AXITEC,Mono-c-Si,0,370.0,337.7,1.940352,,,72.0,9.89,47.91,9.29,39.84,0.004945000000000001,-0.1451673,47.0,1.9156530254176194,9.898028879978085,1.3392260951513716e-10,0.24235941283846782,298.53911121533275,10.45680351073249,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-370MH/120V,AXITEC,Mono-c-Si,0,370.0,341.7,1.81,,,60.0,11.52,40.9,10.76,34.4,0.006382079999999999,-0.1139474,46.0,1.6082045160669267,11.531790121453808,1.0133077111036836e-10,0.14333958942289313,140.0555627907442,16.063890655763746,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-370MH/120VB,AXITEC,Mono-c-Si,0,370.0,345.6,1.81,,,60.0,11.52,40.9,10.76,34.4,0.0061056,-0.114929,44.2,1.5663711906150062,11.533137654869922,5.1313585984221295e-11,0.15191721746413944,133.211473171767,8.949116749615767,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-370MH/144S,AXITEC,Mono-c-Si,0,370.0,343.2,1.984,,,72.0,9.85,47.4,9.35,39.6,0.004137,-0.13035,45.81,1.7627946016913576,9.85376052911021,2.0539667357675575e-11,0.24930338902025057,653.0033535015153,4.790250191107188,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-370MH/144V,AXITEC,Mono-c-Si,0,370.0,343.2,1.984,,,72.0,9.85,47.4,9.35,39.6,0.004137,-0.13035,45.81,1.7627946016913576,9.85376052911021,2.0539667357675575e-11,0.24930338902025057,653.0033535015153,4.790250191107188,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-375M/72S,AXITEC,Mono-c-Si,0,375.0,342.4,1.940352,,,72.0,9.95,48.16,9.33,40.21,0.004975,-0.1459248,47.0,1.9316936770683106,9.958526774090792,1.4534108533474646e-10,0.22161268076785276,258.6026356831096,11.142043525377913,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-375M/72V,AXITEC,Mono-c-Si,0,375.0,342.4,1.940352,,,72.0,9.95,48.16,9.33,40.21,0.004975,-0.1459248,47.0,1.9316936770683106,9.958526774090792,1.4534108533474646e-10,0.22161268076785276,258.6026356831096,11.142043525377913,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-375MH/120V,AXITEC,Mono-c-Si,0,375.0,346.5,1.81,,,60.0,11.6,41.1,10.84,34.6,0.0064264,-0.11450460000000001,46.0,1.518831389118631,11.614566272547847,1.9981205736965716e-11,0.15974444296484103,127.21412004161442,1.7295383138266751,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-375MH/120VB,AXITEC,Mono-c-Si,0,375.0,350.4,1.81,,,60.0,11.6,41.1,10.84,34.6,0.006148,-0.11549100000000002,44.2,1.5780593666970166,11.612567083772003,5.5264497570365347e-11,0.14754752309515376,136.19319428997485,9.54054869590866,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-375MH/144S,AXITEC,Mono-c-Si,0,375.0,348.0,1.984,,,72.0,9.93,47.61,9.43,39.81,0.0041706,-0.13092750000000003,45.81,1.7710165379059535,9.933500636602647,2.0845248340129716e-11,0.2442325874723225,692.7967422698536,4.845362020182125,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-375MH/144V,AXITEC,Mono-c-Si,0,375.0,348.0,1.984,,,72.0,9.93,47.61,9.43,39.81,0.0041706,-0.13092750000000003,45.81,1.7710165379059535,9.933500636602647,2.0845248340129716e-11,0.2442325874723225,692.7967422698536,4.845362020182125,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-380MH/144S,AXITEC,Mono-c-Si,0,380.0,352.7,1.984,,,72.0,10.01,47.8,9.5,40.02,0.0042042,-0.13145,45.81,1.7797821167666747,10.013878820780047,2.15405565186527e-11,0.23698587946482294,611.5850149086402,5.059080405955061,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-380MH/144V,AXITEC,Mono-c-Si,0,380.0,352.7,1.984,,,72.0,10.01,47.8,9.5,40.02,0.0042042,-0.13145,45.81,1.7797821167666747,10.013878820780047,2.15405565186527e-11,0.23698587946482294,611.5850149086402,5.059080405955061,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-385MH/108VB,AXITEC,Mono-c-Si,0,385.0,360.5,1.94,,,54.0,13.52,36.7,12.65,30.44,0.006111039999999999,-0.09747520000000001,43.2,1.385160062355177,13.538649922957216,4.1153910419914144e-11,0.15692072383776007,113.75753163277635,11.909730098401939,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-385MH/144S,AXITEC,Mono-c-Si,0,385.0,357.5,1.984,,,72.0,10.08,48.0,9.58,40.21,0.0042336000000000006,-0.132,45.81,1.7865094979583613,10.083030510434169,2.1492406490841096e-11,0.23380837418698172,777.6868514205856,4.974889014228219,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-385MH/144V,AXITEC,Mono-c-Si,0,385.0,357.5,1.984,,,72.0,10.08,48.0,9.58,40.21,0.0042336000000000006,-0.132,45.81,1.7865094979583613,10.083030510434169,2.1492406490841096e-11,0.23380837418698172,777.6868514205856,4.974889014228219,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-390MBT/108V,AXITEC,Mono-c-Si,1,390.0,363.7,1.93,,,54.0,13.61,36.9,12.73,30.6,0.0048996,-0.091512,46.9,1.3114902706187304,13.63342421783009,8.005015266812499e-12,0.17144929653946606,99.61593578420882,5.057391562259099,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-390MH/108VB,AXITEC,Mono-c-Si,0,390.0,365.3,1.94,,,54.0,13.61,36.85,12.73,30.64,0.006151719999999999,-0.0978736,43.2,1.3928289777648524,13.628394257168182,4.3013225124001666e-11,0.14964479011552428,110.72290617281496,12.252456193897407,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-390MH/144S,AXITEC,Mono-c-Si,0,390.0,364.2,1.98,,,72.0,10.48,48.18,9.66,40.37,0.0045064,-0.12864060000000002,44.52,1.8139982869523306,10.501883332837041,2.9319886703737135e-11,0.22157789766380556,106.11438362194517,10.665600970926176,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-390MH/144V,AXITEC,Mono-c-Si,0,390.0,364.2,1.98,,,72.0,10.48,48.18,9.66,40.37,0.0045064,-0.12864060000000002,44.52,1.8139982869523306,10.501883332837041,2.9319886703737135e-11,0.22157789766380556,106.11438362194517,10.665600970926176,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-395MBT/108V,AXITEC,Mono-c-Si,1,395.0,368.5,1.93,,,54.0,13.7,37.0,12.81,30.8,0.004931999999999999,-0.09176,46.9,1.3177093673335,13.722667082533869,8.523434129108857e-12,0.1603145498203338,96.89422243007171,5.543457022701174,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-395MH/108VB,AXITEC,Mono-c-Si,0,395.0,370.1,1.94,,,54.0,13.7,36.98,12.81,30.84,0.006192399999999999,-0.09821888,43.2,1.400132290252665,13.717927166736967,4.526695069658433e-11,0.14088294468971818,107.66321226528237,12.659391660644484,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-395MH/144S,AXITEC,Mono-c-Si,0,395.0,369.0,1.98,,,72.0,10.56,48.37,9.74,40.55,0.0045408,-0.1291479,44.52,1.8210374093223074,10.581441774202847,2.951548623613439e-11,0.21841563060895752,107.5689467439508,10.654512002932163,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-395MH/144V,AXITEC,Mono-c-Si,0,395.0,369.0,1.98,,,72.0,10.56,48.37,9.74,40.55,0.0045408,-0.1291479,44.52,1.8210374093223074,10.581441774202847,2.951548623613439e-11,0.21841563060895752,107.5689467439508,10.654512002932163,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-400MBT/108US,AXITEC,Mono-c-Si,1,400.0,371.6,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007671999999999999,-0.099057,46.1,1.3972554244129742,13.708573768327355,3.9856506905113645e-11,0.14555899163443753,232.58830173746986,10.728581325313126,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-400MBT/108V,AXITEC,Mono-c-Si,1,400.0,373.3,1.93,,,54.0,13.79,37.1,12.9,31.0,0.004964399999999999,-0.09200799999999999,46.9,1.3234383211487937,13.811109620122915,8.984831552286657e-12,0.14936644150944406,97.57462334273512,5.941503666365742,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-400MH/108VB,AXITEC,Mono-c-Si,0,400.0,374.9,1.94,,,54.0,13.79,37.07,12.9,31.01,0.006233079999999999,-0.09845792,43.2,1.4054515069103215,13.806735574619301,4.724225370216593e-11,0.13185111653059117,108.64442678538741,12.988341022985106,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-400MH/144S,AXITEC,Mono-c-Si,0,400.0,373.8,1.98,,,72.0,10.64,48.55,9.81,40.77,0.0045752,-0.1296285,44.52,1.8298075916043999,10.661053996285682,3.059339222846159e-11,0.20938480169216456,105.81621976042658,10.910559949223902,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-400MH/144V,AXITEC,Mono-c-Si,0,400.0,373.8,1.98,,,72.0,10.64,48.55,9.81,40.77,0.0045752,-0.1296285,44.52,1.8298075916043999,10.661053996285682,3.059339222846159e-11,0.20938480169216456,105.81621976042658,10.910559949223902,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-405MBT/108V,AXITEC,Mono-c-Si,1,405.0,378.1,1.93,,,54.0,13.87,37.2,12.98,31.2,0.004993199999999999,-0.09225600000000002,46.9,1.3291936179512382,13.889601924388248,9.464933222437142e-12,0.13867250450656887,98.12238855057545,6.341961770395264,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-405MH/144S,AXITEC,Mono-c-Si,0,405.0,378.6,1.98,,,72.0,10.71,48.73,9.89,40.95,0.0046053000000000005,-0.1301091,44.52,1.835783534055856,10.729995388396565,3.049157202025956e-11,0.2057151716588234,110.18588149261802,10.815460227538239,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-405MH/144V,AXITEC,Mono-c-Si,0,405.0,378.6,1.98,,,72.0,10.71,48.73,9.89,40.95,0.0046053000000000005,-0.1301091,44.52,1.835783534055856,10.729995388396565,3.049157202025956e-11,0.2057151716588234,110.18588149261802,10.815460227538239,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410MB/144V,AXITEC,Mono-c-Si,0,410.0,381.4,1.95,,,72.0,10.41,49.3,9.91,41.4,0.00443466,-0.1286237,45.4,1.8504313824074166,10.411879461597461,2.787133610556779e-11,0.2177546142816728,1206.1037153092027,12.723887604395397,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410MBT/108US,AXITEC,Mono-c-Si,1,410.0,381.2,1.94,,,54.0,13.86,37.5,13.1,31.3,0.0077616000000000004,-0.100125,46.1,1.4139285285133854,13.868541943106624,4.1545145248748684e-11,0.13954682104728888,226.42611210108373,10.998238485631964,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410MBT/108V,AXITEC,Mono-c-Si,1,410.0,382.9,1.93,,,54.0,13.95,37.3,13.04,31.5,0.005021999999999999,-0.092504,46.9,1.3380215390775663,13.96811664513415,1.0604741649926612e-11,0.11923288536994202,91.81052788722718,7.290265773887954,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-410MH/108V,AXITEC,Mono-c-Si,0,410.0,380.0,1.93,,,54.0,13.94,37.23,13.22,31.03,0.005297199999999999,-0.09873395999999998,46.7,1.3835731033149834,13.946268868831952,2.8483137380487656e-11,0.1446860603969464,321.7364673293911,8.563276882364033,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410MH/108VB,AXITEC,Mono-c-Si,0,410.0,377.8,1.93,,,54.0,13.7,37.3,13.12,31.2,0.0063019999999999994,-0.10294800000000001,47.5,1.3967739899247436,13.700003440050715,3.4605764969549564e-11,0.13590256723209554,541247.099500514,5.961774098017622,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410MH/144S,AXITEC,Mono-c-Si,0,410.0,383.4,1.98,,,72.0,10.79,48.91,9.97,41.12,0.004639699999999999,-0.1305897,44.52,1.8424194321997094,10.809600542226658,3.067617845682698e-11,0.2028924230087667,111.69125969649802,10.8004009485304,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410MH/144V,AXITEC,Mono-c-Si,0,410.0,383.4,1.98,,,72.0,10.79,48.91,9.97,41.12,0.004639699999999999,-0.1305897,44.52,1.8424194321997094,10.809600542226658,3.067617845682698e-11,0.2028924230087667,111.69125969649802,10.8004009485304,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-410TGB/108BB,AXITEC,Mono-c-Si,0,410.0,389.1,1.9,,,54.0,13.85,37.94,13.12,31.25,0.0059555,-0.09522939999999999,43.4,1.3077381819645353,13.862033915465574,3.4421703181430914e-12,0.19693095533666402,226.65056480720872,-3.445212372634811,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-415MBT/108US,AXITEC,Mono-c-Si,1,415.0,386.0,1.94,,,54.0,13.94,37.7,13.18,31.5,0.0078064,-0.10065900000000003,46.1,1.3831989551967714,13.9496010036313,2.0039872941207657e-11,0.14314818734892837,207.84136968764992,4.574960867160664,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-415MH/108V,AXITEC,Mono-c-Si,0,415.0,384.8,1.93,,,54.0,14.02,37.38,13.31,31.19,0.005327599999999999,-0.09913176,46.7,1.3892249023638876,14.025280845986826,2.8722234554478926e-11,0.14148410270952197,375.6229891721826,8.582029243737379,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-415MH/108VB,AXITEC,Mono-c-Si,0,415.0,382.6,1.93,,,54.0,14.02,37.4,13.31,31.2,0.0064491999999999996,-0.10322400000000001,47.5,1.398990581908241,14.02498490456237,3.417638197670784e-11,0.14061534970492895,395.4794359644908,5.6807489189556115,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-415MH/144V,AXITEC,Mono-c-Si,0,415.0,384.5,1.91,,,72.0,10.66,49.6,10.15,40.9,0.00444522,-0.1305472,46.5,1.8520334981632163,10.661120877697607,2.4893484319959396e-11,0.29752850910555584,2829.6165973186226,10.507038511256006,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-415TGB/108BB,AXITEC,Mono-c-Si,0,415.0,394.0,1.9,,,54.0,13.96,38.04,13.23,31.37,0.0060028,-0.0954804,43.4,1.3116804902982941,13.971496396239205,3.5091302985155054e-12,0.19264685824683073,233.92984122129704,-3.3559719337979774,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-420MH/144V,AXITEC,Mono-c-Si,0,420.0,389.3,1.91,,,72.0,10.76,49.7,10.25,41.0,0.00448692,-0.13081040000000002,46.5,1.8557595887264744,10.760755793791173,2.5136835390568886e-11,0.2934094699472239,4177.179529533504,10.50857399032459,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-420TGB/108BB,AXITEC,Mono-c-Si,0,420.0,398.9,1.9,,,54.0,14.07,38.13,13.34,31.49,0.0060501,-0.09570630000000001,43.4,1.315443876950508,14.080954725599025,3.5899328383080988e-12,0.18767858390810258,241.05009819833154,-3.2380750181261306,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-425MB/144V,AXITEC,Mono-c-Si,0,425.0,393.1,2.14,,,72.0,11.22,48.7,10.52,40.4,0.00692274,-0.1521875,45.4,1.9243543371133889,11.23133025206831,1.1256108861732063e-10,0.23213724293860177,229.87837200596874,4.381894191795659,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-425MH/144V,AXITEC,Mono-c-Si,0,425.0,392.3,2.12,,,72.0,11.23,48.3,10.5,40.5,0.00622142,-0.1345638,46.0,1.8419806682484499,11.243121654989766,4.4853979415610807e-11,0.19866167740592822,170.02204805620443,8.894089667497072,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-425TGB/108BB,AXITEC,Mono-c-Si,0,425.0,403.7,1.9,,,54.0,14.16,38.24,13.44,31.64,0.006088799999999999,-0.09598240000000001,43.4,1.3197727286197085,14.169596701265174,3.6595272631392e-12,0.1820067432836156,268.5522264393162,-3.1394766285644975,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-430MB/144V,AXITEC,Mono-c-Si,0,430.0,397.8,2.14,,,72.0,11.3,48.9,10.6,40.6,0.0069721,-0.1528125,45.4,1.9326756634124558,11.310928284393885,1.1404038928125613e-10,0.2277652154600721,235.51244795616583,4.430655489224259,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-430MH/144V,AXITEC,Mono-c-Si,0,430.0,397.0,2.12,,,72.0,11.19,49.2,10.6,40.6,0.00619926,-0.13707120000000003,46.0,1.8928506328394044,11.190008032223083,5.759802713363736e-11,0.2671157720234987,372139.56764060614,11.060499713280672,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-430TGB/108BB,AXITEC,Mono-c-Si,0,430.0,408.6,1.9,,,54.0,14.25,38.34,13.53,31.79,0.0061275,-0.09623340000000001,43.4,1.32435939238166,14.259141933985697,3.776152889525853e-12,0.17566909644416495,273.8244045580284,-2.9396513788973766,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-435MB/144V,AXITEC,Mono-c-Si,0,435.0,402.6,2.14,,,72.0,11.36,49.1,10.67,40.8,0.007009119999999999,-0.1534375,45.4,1.9158700165796523,11.360008535834739,8.418886219753073e-11,0.2285194969675685,304136.0596349038,1.8041108343847618,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-435MH/144V,AXITEC,Mono-c-Si,0,435.0,401.8,2.12,,,72.0,11.26,49.4,10.67,40.8,0.00623804,-0.1376284,46.0,1.9099027953982157,11.264092436989776,6.545271689482414e-11,0.2611435229396352,718.5147218072802,12.177878922324936,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-435TGB/108BB,AXITEC,Mono-c-Si,0,435.0,413.4,1.9,,,54.0,14.34,38.43,13.62,31.94,0.006166199999999999,-0.09645930000000001,43.4,1.328763790423963,14.348684410646774,3.9094550951148e-12,0.16867830468587583,278.52742834884407,-2.7123947123356777,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-440MB/144V,AXITEC,Mono-c-Si,0,440.0,407.3,2.14,,,72.0,11.45,49.3,10.74,41.0,0.00706465,-0.1540625,45.4,1.95033262365469,11.460842406593043,1.1832855635606487e-10,0.2192564944222948,231.54333048183614,4.63178500987107,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-440MH/144V,AXITEC,Mono-c-Si,0,440.0,406.6,2.12,,,72.0,11.33,49.6,10.74,41.0,0.00627682,-0.13818560000000002,46.0,1.9181787315679284,11.333833649164522,6.636503042647504e-11,0.2568537884106585,759.1079616257376,12.246040300477722,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-440TGB/108BB,AXITEC,Mono-c-Si,0,440.0,418.3,1.9,,,54.0,14.43,38.53,13.72,32.09,0.0062049,-0.09671030000000001,43.4,1.3329109431600021,14.437467196373557,3.997452170023707e-12,0.16253173736804388,314.084812813489,-2.587620805311604,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-445MB/144V,AXITEC,Mono-c-Si,0,445.0,412.1,2.14,,,72.0,11.52,49.5,10.81,41.2,0.00710784,-0.1546875,45.4,1.9587140876399092,11.530486946512312,1.1982241125140214e-10,0.21524693804334077,236.45060032443345,4.685119371677367,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-445MH/144V,AXITEC,Mono-c-Si,0,445.0,411.3,2.12,,,72.0,11.4,49.8,10.81,41.2,0.0063156,-0.1387428,46.0,1.9264420399273052,11.403581888556193,6.727155677440849e-11,0.25262248620091615,804.0160442371421,12.312110025583475,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-450MB/144V,AXITEC,Mono-c-Si,0,450.0,416.9,2.14,,,72.0,11.58,49.6,10.87,41.4,0.007144859999999999,-0.15500000000000003,45.4,1.9653738386528081,11.589832309591014,1.2472102459577033e-10,0.20212800908067455,238.0562157327914,4.98011293526294,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-450MH/144V,AXITEC,Mono-c-Si,0,450.0,416.1,2.12,,,72.0,11.47,50.0,10.88,41.4,0.006354380000000001,-0.1393,46.0,1.9347057015998548,11.473336757338846,6.818380812434504e-11,0.2484459122756409,854.0251872127116,12.377680209828018,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-450TGB/108BB,AXITEC,Mono-c-Si,0,450.0,428.0,1.9,,,18.0,14.63,38.8,13.89,32.4,0.0062909,-0.09738799999999999,43.4,1.3448127905077012,14.638952013127804,4.273998598984129e-12,0.15442513053882082,252.37224712915125,-2.1524454564070465,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-460TGB/96BB,AXITEC,Mono-c-Si,0,460.0,435.7,1.94,,,16.0,15.99,36.3,15.14,30.4,0.006715800000000001,-0.088572,44.9,1.258211050310235,16.00259003063908,4.659978444017421e-12,0.126011815016007,160.04162204376735,0.680545742137833,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-515MH/144VB,AXITEC,Mono-c-Si,0,515.0,482.4,2.56,,,72.0,13.51,48.85,12.61,40.86,0.00610652,-0.12974560000000002,43.2,1.8540422560214562,13.528186559016536,4.747430772679048e-11,0.17746851261407612,131.83360426398045,13.230446816532465,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-520MH/144VB,AXITEC,Mono-c-Si,0,520.0,487.2,2.56,,,72.0,13.58,49.0,12.69,41.0,0.00613816,-0.130144,43.2,1.858995510920736,13.597249339672892,4.7285476078295254e-11,0.17591702688220184,138.49534474768453,13.141743057125897,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-525MH/144VB,AXITEC,Mono-c-Si,0,525.0,492.0,2.56,,,72.0,13.65,49.15,12.76,41.15,0.0061698000000000005,-0.1305424,43.2,1.8649246609017143,13.666865533991611,4.770713709913989e-11,0.17338153129656136,140.32511053202182,13.174546105699065,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-530MBT/144V,AXITEC,Mono-c-Si,1,530.0,495.4,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005158720000000001,-0.1415896,43.4,1.888184922346985,13.735841295561363,6.132423347206979e-11,0.16702710468948026,144.66063654085997,6.80265435007689,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-530MBT/144VB,AXITEC,Mono-c-Si,1,530.0,495.4,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005158720000000001,-0.1415896,43.4,1.888184922346985,13.735841295561363,6.132423347206979e-11,0.16702710468948026,144.66063654085997,6.80265435007689,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-530MH/144V,AXITEC,Mono-c-Si,0,530.0,495.7,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005048960000000001,-0.1356736,43.6,1.869096268395765,13.736479468774704,4.6948747744151884e-11,0.1703191942380964,141.79943514041616,9.123596750269808,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-530MH/144VB,AXITEC,Mono-c-Si,0,530.0,496.9,2.56,,,72.0,13.72,49.3,12.83,41.31,0.006201440000000001,-0.1309408,43.2,1.8710893661380052,13.73641217427618,4.828888791553685e-11,0.16997487129093927,142.0930104609815,13.237372833196376,-0.3609,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-535MBT/144V,AXITEC,Mono-c-Si,1,535.0,500.2,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00518504,-0.14202040000000002,43.4,1.8944176670174329,13.80540248776825,6.207377196480134e-11,0.1636604852217208,146.5268563133717,6.862246691937211,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-535MBT/144VB,AXITEC,Mono-c-Si,1,535.0,500.2,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00518504,-0.14202040000000002,43.4,1.8944176670174329,13.80540248776825,6.207377196480134e-11,0.1636604852217208,146.5268563133717,6.862246691937211,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-535MH/144V,AXITEC,Mono-c-Si,0,535.0,500.5,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00507472,-0.13608640000000002,43.6,1.875258582805055,13.806033252642225,4.752088980302346e-11,0.16694848468066048,143.59030390054542,9.184211644244307,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-535MH/144VB,AXITEC,Mono-c-Si,0,535.0,501.7,2.56,,,72.0,13.79,49.45,12.91,41.47,0.006233079999999999,-0.13133920000000002,43.2,1.876523543508348,13.805376348657934,4.841978440354916e-11,0.1667069513711155,149.5081133059965,13.210876516554736,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-540MBT/144V,AXITEC,Mono-c-Si,1,540.0,505.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00521136,-0.14245120000000003,43.4,1.9008928935341285,13.874899036346813,6.303591005096584e-11,0.15943986058414367,148.32076631161073,6.950044601793042,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-540MBT/144VB,AXITEC,Mono-c-Si,1,540.0,505.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00521136,-0.14245120000000003,43.4,1.9008928935341285,13.874899036346813,6.303591005096584e-11,0.15943986058414367,148.32076631161073,6.950044601793042,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-540MH/144V,AXITEC,Mono-c-Si,0,540.0,505.3,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00510048,-0.13649920000000001,43.6,1.8816573621106027,13.875520891334256,4.825499435399979e-11,0.16272540607990535,145.31215353115385,9.273538796144265,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-545MBT/144V,AXITEC,Mono-c-Si,1,545.0,509.8,2.56,,,72.0,13.93,49.75,13.04,41.8,0.005237680000000001,-0.142882,43.4,1.9071263690630793,13.944476983961318,6.379693912914697e-11,0.15615061166153227,150.250773687383,7.008901886626917,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-545MBT/144VB,AXITEC,Mono-c-Si,1,545.0,509.8,2.56,,,72.0,13.93,49.75,13.04,41.8,0.005237680000000001,-0.142882,43.4,1.9071263690630793,13.944476983961318,6.379693912914697e-11,0.15615061166153227,150.250773687383,7.008901886626917,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-545MH/144V,AXITEC,Mono-c-Si,0,545.0,510.1,2.56,,,72.0,13.93,49.75,13.04,41.8,0.00512624,-0.136912,43.6,1.8878203817506956,13.945091424541328,4.883586100754821e-11,0.15943214764458818,147.16237184141428,9.333405671812171,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-550MBT/144US,AXITEC,Mono-c-Si,1,550.0,514.9,2.58,,,72.0,13.89,50.2,13.13,41.9,0.0087507,-0.132026,45.5,1.85854337445892,13.899385936326567,2.5525693780204705e-11,0.19218419087066824,284.4083271386615,8.224652133782982,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-550MBT/144V,AXITEC,Mono-c-Si,1,550.0,514.6,2.56,,,72.0,14.0,49.9,13.11,41.96,0.0052640000000000004,-0.14331280000000002,43.4,1.9133603276024922,14.014062668425538,6.456293321388674e-11,0.15289665107101227,152.215288768733,7.067454389293538,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-550MBT/144VB,AXITEC,Mono-c-Si,1,550.0,514.6,2.56,,,72.0,14.0,49.9,13.11,41.96,0.0052640000000000004,-0.14331280000000002,43.4,1.9133603276024922,14.014062668425538,6.456293321388674e-11,0.15289665107101227,152.215288768733,7.067454389293538,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-550MH/144V,AXITEC,Mono-c-Si,0,550.0,514.9,2.56,,,72.0,14.0,49.9,13.11,41.96,0.005152,-0.1373248,43.6,1.8939835706037638,14.014669727703346,4.942028998461802e-11,0.15617427318168828,149.04433725459532,9.392925373603234,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +AXITEC AC-555MBT/144US,AXITEC,Mono-c-Si,1,555.0,519.7,2.58,,,72.0,13.95,50.4,13.19,42.1,0.0087885,-0.132552,45.5,1.8664650283324231,13.959112917593322,2.5834126706629213e-11,0.18926203457876015,289.72119830783936,8.29173219126789,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-555MBT/144V,AXITEC,Mono-c-Si,1,555.0,519.5,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005290320000000001,-0.1437436,43.4,1.9193534673145207,14.08372580888763,6.51215428786837e-11,0.15055328435867654,154.32858992288678,7.097521550989205,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-555MBT/144VB,AXITEC,Mono-c-Si,1,555.0,519.5,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005290320000000001,-0.1437436,43.4,1.9193534673145207,14.08372580888763,6.51215428786837e-11,0.15055328435867654,154.32858992288678,7.097521550989205,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-555MH/144V,AXITEC,Mono-c-Si,0,555.0,519.7,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005177760000000001,-0.1377376,43.6,1.899912513862717,14.084326930518184,4.984713604029814e-11,0.153825371508525,151.06676060567008,9.423523052285747,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-555TGB/144TS,AXITEC,Mono-c-Si,0,555.0,527.0,2.52,,,72.0,14.01,50.7,13.26,41.86,0.0060243,-0.127257,43.4,1.750237355986375,14.023028365360052,3.6355756904487826e-12,0.25156915025274973,270.52386844594855,-3.095507433564844,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-560TGB/144TS,AXITEC,Mono-c-Si,0,560.0,531.9,2.52,,,72.0,14.07,50.84,13.34,41.99,0.0060501,-0.1276084,43.4,1.7539915734672553,14.080949082187463,3.5938476478012553e-12,0.2499533176284618,321.19981596170913,-3.22933207633602,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-565TGB/144TS,AXITEC,Mono-c-Si,0,565.0,536.7,2.52,,,72.0,14.13,50.98,13.41,42.13,0.0060758999999999995,-0.1279598,43.4,1.758539306431547,14.13977894183363,3.5963214417979672e-12,0.24750454215319567,357.6296136557897,-3.26180739856199,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-570TGB/144TS,AXITEC,Mono-c-Si,0,570.0,541.6,2.52,,,72.0,14.2,51.13,13.49,42.26,0.006105999999999999,-0.12833630000000001,43.4,1.7630434426496084,14.208606658820258,3.5786812785740735e-12,0.24649856720920238,406.69436745899503,-3.3448261509902495,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-575TGB/144TS,AXITEC,Mono-c-Si,0,575.0,546.4,2.52,,,72.0,14.27,51.28,13.56,42.41,0.006136099999999999,-0.12871280000000002,43.4,1.768528867967265,14.27831637440047,3.6157182160728213e-12,0.24382279242922014,418.37357133016843,-3.302737282104706,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-580TGB/144TS,AXITEC,Mono-c-Si,0,580.0,551.3,2.52,,,72.0,14.34,51.43,13.63,42.56,0.006166199999999999,-0.1290893,43.4,1.774014658449343,14.348030823498693,3.652947037821142e-12,0.24117455752829992,430.64612901526084,-3.2608513058554305,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-585TGB/144TS,AXITEC,Mono-c-Si,0,585.0,556.2,2.52,,,72.0,14.41,51.58,13.7,42.72,0.0061963,-0.12946580000000002,43.4,1.779698821212789,14.417743338542747,3.702206772532547e-12,0.23772219070879966,442.39016015358607,-3.193468007386802,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +AXITEC AC-590TGB/144TS,AXITEC,Mono-c-Si,0,590.0,561.0,2.52,,,72.0,14.48,51.7,13.77,42.87,0.0062264,-0.129767,43.4,1.784641751025934,14.487452194672882,3.769674908056648e-12,0.23293998377225242,452.6144507477916,-3.0883882392415405,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Belinus Solar BV BE-M7-GG-108-390,Belinus Solar BV,Mono-c-Si,1,390.0,365.6,1.95,,,54.0,13.5,36.84,12.66,30.82,0.0068985,-0.09460512,44.9,1.3470273279876641,13.516513779716616,1.7498480684569672e-11,0.14230086464529892,116.33083781843973,7.954534729809155,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Belinus Solar BV BE-M7-GG-108-395,Belinus Solar BV,Mono-c-Si,1,395.0,370.4,1.95,,,54.0,13.59,37.03,12.75,31.0,0.006944489999999999,-0.09509303999999999,44.9,1.354148545340648,13.606067542949754,1.768516130390092e-11,0.14022549878329235,118.60335676304534,7.987748532936394,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Belinus Solar BV BE-M7-GG-108-400,Belinus Solar BV,Mono-c-Si,1,400.0,375.2,1.95,,,54.0,13.68,37.2,12.84,31.17,0.00699048,-0.0955296,44.9,1.3606865495906277,13.695572777925639,1.7925243402156867e-11,0.13750184160041437,120.78931482737923,8.046722764351191,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Belinus Solar BV BE-M7-GG-108-405,Belinus Solar BV,Mono-c-Si,1,405.0,380.0,1.95,,,54.0,13.78,37.36,12.92,31.36,0.00704158,-0.09594047999999998,44.9,1.3684746612069099,13.796063548766977,1.874146274784927e-11,0.13204554146907208,113.27432026727902,8.380031918341128,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Belinus Solar BV BE-M7-GG-108-410,Belinus Solar BV,Mono-c-Si,1,410.0,384.8,1.95,,,54.0,13.86,37.54,13.0,31.55,0.00708246,-0.09640272,44.9,1.3756630487957653,13.87549178096603,1.9080648595449544e-11,0.1285164299067078,114.97953200577453,8.485991596539227,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc BF500J-12X12UW,Bila Solar Inc,Mono-c-Si,0,500.0,465.8,2.69,,,72.0,13.36,48.74,12.11,41.35,0.002672,-0.12477440000000002,44.94,1.8085804528368923,13.391966765270118,2.476949838353975e-11,0.1348629451437751,56.36381830515413,12.080229928004771,-0.3463,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc DF500J-12X12UW,Bila Solar Inc,Mono-c-Si,0,500.0,468.0,2.69,,,72.0,13.32,48.7,12.07,41.3,0.0034898400000000006,-0.125646,43.59,1.823374120710584,13.351467641286764,3.141268768562427e-11,0.13352970805483155,56.5220538144197,13.298308296967654,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc BF505J-12X12UW,Bila Solar Inc,Mono-c-Si,0,505.0,470.6,2.69,,,72.0,13.41,48.94,12.16,41.58,0.002682,-0.1252864,44.94,1.817014488684228,13.440545158052778,2.52467951360473e-11,0.12928018240064618,56.75685963983763,12.217971176220903,-0.3463,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc DF505J-12X12UW,Bila Solar Inc,Mono-c-Si,0,505.0,472.8,2.69,,,72.0,13.38,48.9,12.13,41.54,0.00350556,-0.126162,43.59,1.8320481861716464,13.409810424969905,3.211740460533586e-11,0.1268862133014003,56.95113499649231,13.458757307247808,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc BF510J-12X12UW,Bila Solar Inc,Mono-c-Si,0,510.0,475.4,2.69,,,72.0,13.46,49.14,12.21,41.81,0.0026920000000000004,-0.1257984,44.94,1.8254461845249739,13.48914372385492,2.572842607574859e-11,0.12374489655327217,57.15145799791629,12.354283352488277,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc DF510J-12X12UW,Bila Solar Inc,Mono-c-Si,0,510.0,477.6,2.69,,,72.0,13.44,49.1,12.19,41.78,0.00352128,-0.126678,43.59,1.8407196180034258,13.46817900162611,3.2830569162839464e-11,0.12031031745983856,57.38211290667944,13.617550695541972,-0.3477,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc BF515J-12X12UW,Bila Solar Inc,Mono-c-Si,0,515.0,480.1,2.69,,,72.0,13.51,49.34,12.26,42.06,0.002702,-0.12631040000000002,44.94,1.8343355704934052,13.537324282591012,2.639075050922278e-11,0.11638014093918835,57.542067240417175,12.55025215310789,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc DF515J-12X12UW,Bila Solar Inc,Mono-c-Si,0,515.0,482.4,2.69,,,72.0,13.5,49.3,12.25,42.02,0.003537,-0.127194,43.59,1.8493882969224449,13.526572874324014,3.3552096520218487e-11,0.11380101535001233,57.81511217057882,13.774694173864907,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA520US-6x24GG,Bila Solar Inc,Mono-c-Si,1,520.0,482.1,2.51,,,72.0,13.58,49.0,12.69,40.99,0.0043456,-0.12397,47.96,1.7712131643819886,13.600521644347612,1.2778248191403784e-11,0.19223524952480162,127.20982051187404,7.0502670528837905,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc BF520J-12X12UW,Bila Solar Inc,Mono-c-Si,0,520.0,484.9,2.69,,,72.0,13.56,49.54,12.31,42.26,0.002712,-0.1268224,44.94,1.8420729809531635,13.58661740038044,2.6615749203551406e-11,0.11374848664904164,57.948163942999194,12.592334312824029,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc DF520J-12X12UW,Bila Solar Inc,Mono-c-Si,0,520.0,487.2,2.69,,,72.0,13.56,49.5,12.31,42.26,0.00355272,-0.12771,43.59,1.858054518357907,13.584991678969397,3.428208888829417e-11,0.10735724956948958,58.249960247387804,13.930244649386552,-0.3477,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc AA525US-6x24GG,Bila Solar Inc,Mono-c-Si,1,525.0,486.8,2.51,,,72.0,13.65,49.15,12.76,41.15,0.004368,-0.1243495,47.96,1.7770686915584604,13.670025801246966,1.293553989959067e-11,0.188768395300635,128.66843984878503,7.110676460274421,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc BF525J-12X12UW,Bila Solar Inc,Mono-c-Si,0,525.0,489.7,2.69,,,72.0,13.61,49.74,12.36,42.54,0.002722,-0.12733440000000001,44.94,1.8516455527478561,13.63419404999079,2.7561728759781063e-11,0.10369744315392525,58.33344163957481,12.875748394428769,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc DF525J-12X12UW,Bila Solar Inc,Mono-c-Si,0,525.0,492.0,2.69,,,72.0,13.62,49.7,12.37,42.5,0.00356844,-0.128226,43.59,1.86671797177856,13.643434896379084,3.502036990396022e-11,0.10097809039848922,58.686907388821126,14.084182664415849,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA530US-6x24GG,Bila Solar Inc,Mono-c-Si,1,530.0,491.6,2.51,,,72.0,13.72,49.3,12.83,41.31,0.004390400000000001,-0.124729,47.96,1.7829246829859091,13.739538156389079,1.3093888109279393e-11,0.18533954705396344,130.14833856849833,7.170772720251333,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc BF530J-12X12UW,Bila Solar Inc,Mono-c-Si,0,530.0,494.5,2.69,,,72.0,13.66,49.94,12.41,42.76,0.002732,-0.1278464,44.94,1.8598380172184654,13.683090631518828,2.7972709255056632e-11,0.09928803612545864,58.73700657044855,12.975880599110761,-0.3463,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc DF530J-12X12UW,Bila Solar Inc,Mono-c-Si,0,530.0,496.8,2.69,,,72.0,13.68,49.86,12.43,42.74,0.0035841600000000003,-0.1286388,43.59,1.8746716635546528,13.70117161264795,3.617096332762814e-11,0.09141544611729778,59.06792855022339,14.34038982984247,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA535US-6x24GG,Bila Solar Inc,Mono-c-Si,1,535.0,496.4,2.51,,,72.0,13.79,49.45,12.9,41.47,0.0044128,-0.1251085,47.96,1.7887811268661629,13.809058595097145,1.3253291057140032e-11,0.18194808519301714,131.65000291836273,7.230556697893858,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc DF535J-12X12UW,Bila Solar Inc,Mono-c-Si,0,535.0,501.6,2.69,,,72.0,13.74,50.1,12.49,42.98,0.00359988,-0.129258,43.59,1.8840375874694417,13.760393097090128,3.652213998507455e-11,0.08840957198258485,59.56660313272268,14.38742555675753,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA540US-6x24GG,Bila Solar Inc,Mono-c-Si,1,540.0,501.2,2.51,,,72.0,13.86,49.6,12.97,41.64,0.0044352,-0.12548800000000002,47.96,1.794852486542579,13.878505870035482,1.3457824072176406e-11,0.1777107762440081,133.096761154191,7.318728197512942,-0.333,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA545US-6x24GG,Bila Solar Inc,Mono-c-Si,1,545.0,505.9,2.51,,,72.0,13.93,49.75,13.04,41.8,0.0044576,-0.1258675,47.96,1.800709622229137,13.948043100178317,1.361966925718543e-11,0.17439716295483942,134.64163378876341,7.377781720216731,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc AA550US-6x24GG,Bila Solar Inc,Mono-c-Si,1,550.0,510.7,2.51,,,72.0,14.0,49.9,13.11,41.96,0.0044800000000000005,-0.126247,47.96,1.8065671740066558,14.017588074698066,1.3782563371280778e-11,0.17111910215784687,136.20976010913202,7.43652836737012,-0.333,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA555US-6x24GG,Bila Solar Inc,Mono-c-Si,1,555.0,515.5,2.51,,,72.0,14.07,50.05,13.18,42.12,0.004502400000000001,-0.12662649999999998,47.96,1.8124251460612064,14.087140695243425,1.3946507480204626e-11,0.16787602440669688,137.8016256073745,7.4949705387589844,-0.333,N,2025.7.3,6/23/2025,2.0,first_pass +Bila Solar Inc AA560US-6x24GG,Bila Solar Inc,Mono-c-Si,1,560.0,520.3,2.51,,,72.0,14.14,50.2,13.25,42.28,0.0045248,-0.127006,47.96,1.8182835613618062,14.156700860699985,1.4111506818325339e-11,0.16466736856432093,139.41776052865188,7.553114079059262,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Bila Solar Inc AA565US-6x24GG,Bila Solar Inc,Mono-c-Si,1,565.0,525.1,2.51,,,72.0,14.21,50.33,13.32,42.42,0.0045472,-0.1273349,47.96,1.8233507083102387,14.22629251994115,1.4263156348667287e-11,0.1616982587416401,141.02988801428967,7.602110001044979,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +BLUESUN GROUP LIMITED BSM565M10-72HBD,BLUESUN GROUP LIMITED,Mono-c-Si,1,565.0,534.1,2.58,,,72.0,14.37,49.84,13.78,41.01,0.00616473,-0.12200832000000002,43.4,1.761311256950244,14.370003343753945,7.382121157360099e-12,0.23268594738392034,999995.5212580801,5.067931356599313,-0.3195,N,2025.7.3,6/23/2025,2.0,first_pass +BLUESUN GROUP LIMITED BSM580M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,580.0,550.7,2.58,,,72.0,13.8,52.0,13.17,44.0,0.0066240000000000005,-0.11336,43.2,1.8177634275046906,13.803149726776672,5.17694819042032e-12,0.1683882138787129,737.764778801581,15.018387476820768,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +BLUESUN GROUP LIMITED BSM585M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,585.0,555.6,2.58,,,72.0,13.85,52.2,13.23,44.2,0.006648000000000001,-0.11379600000000001,43.2,1.8245881198272904,13.852463521998361,5.187432048815055e-12,0.16587736019399885,932.5678665246049,14.998739184743348,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +BLUESUN GROUP LIMITED BSM590M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,590.0,560.5,2.58,,,72.0,13.9,52.4,13.29,44.4,0.006672000000000001,-0.114232,43.2,1.8314129212496657,13.901798173763762,5.1979354454374835e-12,0.16338941738961976,1263.0108296955545,14.979240298128214,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +BLUESUN GROUP LIMITED BSM595M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,595.0,565.3,2.58,,,72.0,13.95,52.5,13.35,44.6,0.006696,-0.11445000000000001,43.2,1.836331152857211,13.95119764265961,5.338068359614954e-12,0.1534234268381217,1787.0579474489339,15.19357296163031,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +BLUESUN GROUP LIMITED BSM600M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,600.0,570.2,2.58,,,72.0,14.0,52.7,13.41,44.8,0.006720000000000001,-0.114886,43.2,1.843154397752599,14.00060010737247,5.348226735652465e-12,0.15101513928300328,3523.056489730184,15.173180503576605,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +BLUESUN GROUP LIMITED BSM605M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,605.0,575.1,2.58,,,72.0,14.05,52.9,13.47,44.9,0.006744000000000001,-0.11532200000000001,43.2,1.8483209943055607,14.050002199425673,5.222990442345662e-12,0.15654185153919653,999999.7398126596,14.91030847004397,-0.301,N,2025.7.3,6/23/2025,2.0,first_pass +BLUESUN GROUP LIMITED BSM610M10-72HNH,BLUESUN GROUP LIMITED,Mono-c-Si,1,610.0,579.9,2.58,,,72.0,14.1,53.1,13.53,45.1,0.006768,-0.115758,43.2,1.8564452715385193,14.100002129955097,5.334209181046718e-12,0.15105974882164258,999999.4846228177,15.076210764639487,-0.301,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar CoLtd BSM360M-60HPH,Bluesun Solar CoLtd,Mono-c-Si,0,360.0,334.0,1.82,,,60.0,11.15,40.7,10.5,34.3,0.0037352500000000003,-0.11973940000000001,45.5,1.5374701392539556,11.158176772725628,3.493686371787805e-11,0.1533910574312434,209.16691250174011,1.3364317194242623,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM365M-60HPH,Bluesun Solar CoLtd,Mono-c-Si,0,365.0,338.7,1.82,,,60.0,11.2,40.9,10.56,34.6,0.0037519999999999997,-0.1203278,45.5,1.5471458992098648,11.20695201522684,3.642978631755149e-11,0.1393131800838252,224.43961592910676,1.6383636375568638,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM370M-60HPH,Bluesun Solar CoLtd,Mono-c-Si,0,370.0,343.5,1.82,,,60.0,11.26,41.1,10.61,34.9,0.0037721000000000005,-0.12091620000000002,45.5,1.5582535810450702,11.266666066137162,3.8851855628555876e-11,0.12496890852610061,211.09150316581471,2.126923860495421,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM395M10-54HPH,Bluesun Solar CoLtd,Mono-c-Si,0,395.0,368.1,1.953,,,54.0,13.69,36.75,12.81,30.85,0.0069955899999999994,-0.10267949999999999,44.8,1.403458974736089,13.70500239840579,5.6759341803537717e-11,0.12064972102859052,110.09537610376569,8.961059874112506,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM400M10-54HPH,Bluesun Solar CoLtd,Mono-c-Si,0,400.0,372.9,1.953,,,54.0,13.78,37.0,12.89,31.05,0.00704158,-0.103378,44.8,1.4130059692811547,13.795439343978543,5.711178669860268e-11,0.12152583316931015,108.46484138720497,8.959110908870189,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM405M10-54HPH,Bluesun Solar CoLtd,Mono-c-Si,0,405.0,377.6,1.953,,,54.0,13.86,37.25,12.97,31.24,0.00708246,-0.10407649999999999,44.8,1.4217906663702766,13.875424298451554,5.667224285084568e-11,0.12344424954244082,110.92480604791555,8.838259487183347,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM410M10-54HPH,Bluesun Solar CoLtd,Mono-c-Si,0,410.0,382.4,1.953,,,54.0,13.94,37.5,13.05,31.43,0.00712334,-0.104775,44.8,1.430575808123991,13.955398417279534,5.6244013901658534e-11,0.125339061892251,113.46793031618999,8.719090735494536,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM415M10-54HPH,Bluesun Solar CoLtd,Mono-c-Si,0,415.0,387.2,1.953,,,54.0,14.02,37.75,13.13,31.64,0.00716422,-0.1054735,44.8,1.4398394215445287,14.035179725698745,5.631155725635182e-11,0.1254525321469757,115.86800389044171,8.677743585530987,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar CoLtd BSM430M-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,430.0,398.3,2.17,,,72.0,11.26,48.8,10.73,40.1,0.0066659200000000005,-0.1475224,45.2,1.8893262992631312,11.26000515055139,6.823504208322175e-11,0.2779832326602271,607753.7887287909,3.6002230518912137,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM435M10-54HNH,Bluesun Solar CoLtd,Mono-c-Si,0,435.0,413.7,1.94,,,54.0,14.31,38.7,13.57,32.1,0.0064395,-0.094815,43.1,1.8479681865515787,14.310049111400588,9.990006589352596e-14,2.34837141809491,815275.7454851891,99.99999371696501,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM435M-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,435.0,402.9,2.17,,,72.0,11.16,49.8,10.51,41.4,0.00837,-0.1485036,45.3,1.9747284262325364,11.167630444598117,1.229655146206924e-10,0.22772913330478042,333.0680411060258,10.079801025529674,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM435M-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,435.0,403.0,2.17,,,72.0,11.33,49.0,10.8,40.3,0.00670736,-0.148127,45.2,1.8981903969478162,11.330003028926814,6.971472472266235e-11,0.26731240897674896,999999.8644702794,3.7279944400806393,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar CoLtd BSM440M10-54HNH,Bluesun Solar CoLtd,Mono-c-Si,0,440.0,418.5,1.94,,,54.0,14.39,38.9,13.65,32.2,0.0064754999999999995,-0.095305,43.1,1.3431002571334336,14.400456538319176,3.7604466934616844e-12,0.1810404824579878,249.14292558254655,-0.6880225886291299,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +Bluesun Solar CoLtd BSM440M-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,440.0,407.7,2.17,,,72.0,11.22,50.0,10.58,41.6,0.008415,-0.1491,45.3,1.9652320942547377,11.220008566470966,1.001247862048935e-10,0.22709290032958845,297445.8731176091,8.175544310769393,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM440M-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,440.0,407.8,2.17,,,72.0,11.4,49.2,10.87,40.5,0.0067488,-0.14873160000000002,45.2,1.9068107977128372,11.400005138326451,7.097887972812942e-11,0.26910858770905305,597082.9866807457,3.827038764800452,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM445M-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,445.0,412.5,2.17,,,72.0,11.29,50.2,10.65,41.8,0.0084675,-0.1496964,45.3,1.9906444062659947,11.29642621601982,1.2470717788071537e-10,0.2198006556945993,386.16030250029667,10.096251909924328,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM445M-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,445.0,412.6,2.17,,,72.0,11.47,49.4,10.94,40.7,0.006790240000000001,-0.1493362,45.2,1.915551623657869,11.47000512902016,7.237299095126621e-11,0.26475706373582336,592107.211801311,3.938909668123056,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM450M-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,450.0,417.2,2.17,,,72.0,11.36,50.4,10.72,42.0,0.00852,-0.1502928,45.3,1.982980701323951,11.360008153046595,1.0404484709069292e-10,0.2187271396950907,304771.9135689536,8.403584994100779,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM450M-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,450.0,417.4,2.17,,,72.0,11.54,49.6,11.01,40.9,0.00683168,-0.1499408,45.2,1.924291520804666,11.540005117615358,7.378188281042238e-11,0.26046127600812036,587360.756795907,4.0497747027891435,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM455M-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,455.0,422.0,2.17,,,72.0,11.43,50.6,10.79,42.2,0.0085725,-0.1508892,45.3,1.9918492573918811,11.43000651354162,1.060300556211842e-10,0.2146268514077865,376643.3022534545,8.515624568806997,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM455M-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,455.0,422.1,2.17,,,72.0,11.61,49.8,11.08,41.1,0.00687312,-0.1505454,45.2,1.9330305037888793,11.610005104140484,7.520554338040786e-11,0.25622016226211053,582835.9335863249,4.159647616069388,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM460M-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,460.0,426.8,2.17,,,72.0,11.5,50.8,10.86,42.4,0.008625,-0.15148560000000003,45.3,2.0158830904530123,11.505618850646735,1.2948265010909266e-10,0.20780073325739934,425.30202486314465,10.263740584198366,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM545M10-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,545.0,503.4,2.591,,,72.0,13.93,49.76,13.04,41.8,0.008135120000000001,-0.1460456,45.4,1.9955217285242652,13.941902369896981,2.020245533138922e-10,0.14208992431978462,166.29568067230187,14.60754433055536,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar CoLtd BSM550M10-72HBD,Bluesun Solar CoLtd,Mono-c-Si,1,550.0,508.2,2.591,,,72.0,14.0,49.92,13.11,41.96,0.008176000000000001,-0.1465152,45.4,2.0022412764382227,14.01157557271183,2.0387789236238984e-10,0.1396257885275673,168.86949330184873,14.644485208268554,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM550M10-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,550.0,513.2,2.591,,,72.0,14.0,49.92,13.11,41.96,0.007154000000000001,-0.13947648,44.8,1.9069751270781947,14.014392148726598,5.853966003153184e-11,0.15557841275469347,151.3393059326555,9.033197597276395,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM555M10-72HPH,Bluesun Solar CoLtd,Mono-c-Si,0,555.0,518.0,2.591,,,72.0,14.07,50.08,13.18,42.12,0.007189770000000001,-0.13992352,44.8,1.9133662506196634,14.08404038880854,5.907754588750748e-11,0.15311619539154406,153.43911895296938,9.068665263561053,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar CoLtd BSM585M10-72HNH,Bluesun Solar CoLtd,Mono-c-Si,0,585.0,556.5,2.56,,,72.0,14.55,51.2,13.76,42.5,0.0065475,-0.12544,43.1,1.7725350689028465,14.563844057485658,4.09373217308099e-12,0.2258266349977697,237.3420904871206,-0.06590716705807184,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar CoLtd BSM590M10-72HNH,Bluesun Solar CoLtd,Mono-c-Si,0,590.0,561.4,2.56,,,72.0,14.63,51.3,13.83,42.7,0.0065835,-0.125685,43.1,1.7786502500392587,14.643974608520978,4.294335995127757e-12,0.21538598187426702,225.48731256590537,0.28691699717187996,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM635M10-78HNH,Bluesun Solar CoLtd,Mono-c-Si,0,635.0,604.2,2.77,,,78.0,14.43,56.0,13.68,46.4,0.0064935,-0.13720000000000002,43.1,1.9349081350355437,14.441097861699213,3.847580374814371e-12,0.25612958726010254,333.03261941818187,-0.5197672277851582,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar CoLtd BSM640M10-78HNH,Bluesun Solar CoLtd,Mono-c-Si,0,640.0,609.0,2.77,,,78.0,14.51,56.2,13.74,46.6,0.0065295,-0.13769,43.1,1.9434993666005347,14.522440590619375,3.961374164706553e-12,0.2527697321231483,294.81629385631237,-0.32017652834888827,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM265M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,265.0,238.1,1.6268,,,60.0,9.05,38.26,8.52,31.11,0.0057377,-0.13547866,46.6,1.6240732223684784,9.054170904651166,5.280668763343149e-10,0.28028422998856134,608.1586313110308,6.036979169559025,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM270M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,270.0,242.7,1.6268,,,60.0,9.17,38.46,8.62,31.33,0.00581378,-0.13618686000000002,46.6,1.6356449365472208,9.175351926258957,5.582354015640016e-10,0.2700462956702555,462.69796469339036,6.40745106967331,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM275M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,275.0,247.4,1.6268,,,60.0,9.25,38.86,8.73,31.51,0.0058645,-0.13760326,46.6,1.6446646604507658,9.252210512433903,5.049742361245628e-10,0.2906539046126313,1216.2569589378252,5.45743591817908,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM280M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,280.0,252.0,1.6268,,,60.0,9.37,39.05,8.84,31.68,0.005940579999999999,-0.13827604999999998,46.6,1.6535159446788723,9.372563454914495,5.17222716102302e-10,0.28617507967076516,1046.0346644090296,5.553483614513898,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM285M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,285.0,256.7,1.6268,,,60.0,9.49,39.25,8.95,31.85,0.00601666,-0.13898425,46.6,1.6625393759609615,9.492902408753316,5.277501681602507e-10,0.28295165323405774,925.1671006045988,5.61826229262858,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM290M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,290.0,261.3,1.6268,,,60.0,9.56,39.46,9.06,32.07,0.00606104,-0.13972786,46.6,1.6695760636416723,9.571569943015346,5.206468299809413e-10,0.2758931455984716,999999.980550971,5.41819830615019,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM295M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,295.0,266.0,1.6268,,,60.0,9.72,39.64,9.14,32.29,0.0061624800000000006,-0.14036524000000003,46.6,1.6854920325423866,9.725415548141417,5.891784953520707e-10,0.26277773378783686,471.6421109860132,6.369257400821876,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM300M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,300.0,270.6,1.6268,,,60.0,9.84,39.82,9.23,32.51,0.00623856,-0.14100262000000002,46.6,1.6976732378803763,9.847334339655337,6.330267661241469e-10,0.25108960745190123,336.8704688223921,6.89268259678697,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM305M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,305.0,280.2,1.63,,,60.0,9.96,40.0,9.32,32.73,0.006513840000000001,-0.13355999999999998,44.9,1.6353177831922803,9.971363206140543,2.333744464340258e-10,0.25632005447654843,224.66792459457955,4.510452338608254,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM310M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,310.0,285.0,1.63,,,60.0,10.08,40.18,9.41,32.95,0.00659232,-0.13416102,44.9,1.6468453238137426,10.093034785905633,2.505044677542328e-10,0.24509686879267495,189.53718312600037,5.017705368365235,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM315M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,315.0,289.7,1.63,,,60.0,10.04,40.7,9.49,33.2,0.00656616,-0.1358973,44.9,1.652229682042404,10.043296347975405,2.0026672387932908e-10,0.2723436780732391,829.5032112026145,3.124195576845302,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM320M-60,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,320.0,294.4,1.63,,,60.0,10.15,40.9,9.59,33.4,0.0066381,-0.1365651,44.9,1.6617427470894528,10.153710815987571,2.065614333508441e-10,0.26618262093778017,728.0755022643596,3.293185921138251,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM320P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,320.0,292.2,1.938,,,72.0,9.05,46.19,8.66,36.95,0.005104200000000001,-0.15436698,45.1,1.8614363323964813,9.050003540908405,1.5135224491540248e-10,0.39108342071052327,999790.5479128596,1.6704885706932993,-0.4211,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM325P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,325.0,296.9,1.938,,,72.0,9.16,46.38,8.74,37.17,0.00516624,-0.15500196000000002,45.1,1.8681536397973189,9.160003618311487,1.5129185497209632e-10,0.39491382516388984,999999.1408343511,1.5682219427223045,-0.4211,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM330P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,330.0,301.6,1.938,,,72.0,9.26,46.57,8.83,37.39,0.00522264,-0.15563694,45.1,1.8768523686664975,9.260003585888947,1.5507370461053054e-10,0.38714848206936137,999999.5452195052,1.6815678105991307,-0.4211,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM335P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,335.0,306.3,1.938,,,72.0,9.36,46.76,8.91,37.61,0.00527904,-0.15627192,45.1,1.8845662096273323,9.360003604487769,1.568650382258108e-10,0.38499237564573313,999991.8268064593,1.687668481795281,-0.4211,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM340P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,340.0,311.0,1.938,,,72.0,9.46,46.95,8.99,37.83,0.005335440000000001,-0.15690690000000002,45.1,1.8922973479994925,9.460003619714621,1.586939776550774e-10,0.38253623300969497,999999.9065603381,1.6955795269897593,-0.4211,N,2025.7.3,6/23/2025,2.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM345P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,345.0,315.7,1.938,,,72.0,9.56,47.14,9.07,38.05,0.00539184,-0.15754188000000002,45.1,1.9000090724274388,9.560004466896485,1.6048419362633765e-10,0.3834331672316743,820792.7387987053,1.7013426882579554,-0.4211,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM350P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,350.0,320.4,1.938,,,72.0,9.66,47.33,9.15,38.27,0.00544824,-0.15817686,45.1,1.9078615069478984,9.660010234633559,1.62572093385025e-10,0.37308260736078447,352146.1031851828,1.722034070235511,-0.4211,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM355P-72,Bluesun Solar Energy Tech CoLtd,Multi-c-Si,0,355.0,325.1,1.938,,,72.0,9.76,47.52,9.22,38.49,0.00550464,-0.15881184,45.1,1.921687641994305,9.763494049793774,1.7707627633552565e-10,0.3618790518864776,1010.8443332668772,2.3537705915324074,-0.4211,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM365M-72,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,365.0,335.4,1.94,,,72.0,9.93,48.01,9.29,39.29,0.00649422,-0.16030539,44.9,1.9631739824012493,9.941473893410356,2.337253129158977e-10,0.30781768962088724,266.39865188486493,4.549391493921933,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM370M-72,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,370.0,340.1,1.94,,,72.0,10.03,48.23,9.37,39.51,0.00655962,-0.16103996999999998,44.9,1.9748414203618292,10.04258501631383,2.4357287890569736e-10,0.3009627182491128,239.86113294038213,4.819095449211141,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM375M-72,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,375.0,344.9,1.94,,,72.0,10.12,48.45,9.44,39.73,0.0066184799999999995,-0.16177455,44.9,1.986582446622832,10.13369131832345,2.5367677331502575e-10,0.2945056805098349,217.68522279946262,5.093578248105557,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM380M-72,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,380.0,349.6,1.94,,,72.0,10.22,48.67,9.52,39.95,0.0066838800000000005,-0.16250913,44.9,1.9982464493683993,10.234710206733574,2.6411559097050875e-10,0.2878715030890471,200.00038016427231,5.358077615257439,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Bluesun Solar Energy Tech CoLtd BSM385M-72,Bluesun Solar Energy Tech CoLtd,Mono-c-Si,0,385.0,354.4,1.94,,,72.0,10.31,48.89,9.59,40.17,0.0067427400000000005,-0.16324371,44.9,2.009987489467222,10.325723487214244,2.748289844279505e-10,0.2816105247815675,184.6539915308944,5.627694358199251,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-250,Boviet Solar Technology Co Ltd,Multi-c-Si,0,250.0,225.6,1.6268799999999999,1.64,0.992,60.0,8.85,37.5,8.31,30.1,0.0055046999999999995,-0.1323375,45.4,1.5815796769791977,8.856162962731238,4.4268767410586365e-10,0.33660934233134393,483.3704182357492,5.100236388285716,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-255,Boviet Solar Technology Co Ltd,Multi-c-Si,0,255.0,231.0,1.60974,1.626,0.99,60.0,9.0,37.4,8.45,30.2,0.006534,-0.12057760000000001,45.5,1.5642785002413522,9.006928866015437,3.686482662002943e-10,0.3093925412609615,401.87436102553954,13.164409882024245,-0.4426,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-260,Boviet Solar Technology Co Ltd,Mono-c-Si,0,260.0,235.3,1.6268799999999999,1.64,0.992,60.0,9.14,38.1,8.47,30.7,0.0037839600000000003,-0.1365123,45.7,1.5705549447853373,9.160004358859862,2.594722150761994e-10,0.32651315528140556,149.18401035307164,-0.8268434605002423,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-260,Boviet Solar Technology Co Ltd,Multi-c-Si,0,260.0,235.7,1.60974,1.626,0.99,60.0,9.12,37.5,8.56,30.4,0.0066211199999999994,-0.12090000000000001,45.5,1.5722382044408318,9.127186201530225,3.953186966974375e-10,0.28968315933480365,367.63664875314464,13.68741809099424,-0.4426,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-265,Boviet Solar Technology Co Ltd,Mono-c-Si,0,265.0,242.7,1.627,,,60.0,8.98,38.2,8.5,31.2,0.005028800000000001,-0.11918400000000001,44.9,1.526634644429263,8.982515716446052,1.214829709555286e-10,0.28642935604022424,1022.4268970544583,7.128297412048014,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-265,Boviet Solar Technology Co Ltd,Multi-c-Si,0,265.0,244.8,1.627,1.626,0.99,60.0,9.07,38.1,8.61,30.8,0.006421560000000001,-0.1167384,43.7,1.508435918789354,9.07412955581972,9.736762108748656e-11,0.32697891038209786,999999.9254934926,6.886757171122954,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-270,Boviet Solar Technology Co Ltd,Mono-c-Si,0,270.0,247.4,1.627,,,60.0,9.09,38.4,8.6,31.4,0.0050904,-0.119808,44.9,1.5359849486329558,9.092943759221479,1.2563346296905254e-10,0.27943780595824447,862.872919410905,7.315787557633527,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-270,Boviet Solar Technology Co Ltd,Multi-c-Si,0,270.0,249.5,1.627,1.64,0.992,60.0,9.16,38.3,8.71,31.0,0.00648528,-0.1173512,43.7,1.5187248065109384,9.160002864726563,1.0224154455359401e-10,0.31268041847451106,999999.9633148648,7.227764014218806,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-275,Boviet Solar Technology Co Ltd,Mono-c-Si,0,275.0,252.3,1.627,,,60.0,9.21,38.6,8.71,31.6,0.0027630000000000003,-0.16984000000000002,44.9,1.515739803643334,9.214069616774173,7.975791170795143e-11,0.2795163849219327,632.5769416146248,-26.568354945733432,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-275,Boviet Solar Technology Co Ltd,Multi-c-Si,0,275.0,254.3,1.627,1.64,0.992,60.0,9.25,38.5,8.82,31.2,0.006549,-0.117964,43.7,1.5294479797124303,9.250002734260837,1.0811115794694015e-10,0.29553753683187944,999999.7562917056,7.627852053720652,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-280,Boviet Solar Technology Co Ltd,Mono-c-Si,0,280.0,257.0,1.627,,,60.0,9.33,38.8,8.81,31.8,0.0027990000000000003,-0.17071999999999998,44.9,1.5257995748422215,9.335295576866006,8.366635676502428e-11,0.2724435885517623,480.004140645565,-26.357868020123906,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-280,Boviet Solar Technology Co Ltd,Multi-c-Si,0,280.0,259.0,1.627,1.64,0.992,60.0,9.34,38.7,8.92,31.4,0.00661272,-0.11857680000000001,43.7,1.5393676471771418,9.34000264448103,1.1274519309127403e-10,0.2830796215482806,999999.2694044313,7.909287687190427,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-285,Boviet Solar Technology Co Ltd,Mono-c-Si,0,285.0,262.1,1.627,,,60.0,9.56,38.9,8.94,31.9,0.00848928,-0.11522180000000001,44.8,1.5907406080485618,9.571175704277799,2.2512233354142e-10,0.25094238094192267,214.66292079009256,17.712116349683228,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-285,Boviet Solar Technology Co Ltd,Multi-c-Si,0,285.0,263.7,1.627,1.64,0.992,60.0,9.45,39.0,9.02,31.6,0.0066906000000000005,-0.119496,43.7,1.5499303987302586,9.450002735626164,1.115654933670992e-10,0.2894269514063618,999999.4738213175,7.715467601974566,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-290,Boviet Solar Technology Co Ltd,Mono-c-Si,0,290.0,266.9,1.627,,,60.0,9.65,39.2,9.07,32.0,0.0085692,-0.11611040000000002,44.8,1.5948928115771714,9.657791936277194,2.0196874494324884e-10,0.26986267318741214,334.21411335230636,16.56989904261388,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-290,Boviet Solar Technology Co Ltd,Multi-c-Si,0,290.0,268.5,1.627,,,60.0,9.56,39.2,9.12,31.8,0.00676848,-0.1201088,43.7,1.558333425876152,9.560002728557095,1.1369578262583278e-10,0.2853572269744964,999999.6848460815,7.779447439480244,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-295,Boviet Solar Technology Co Ltd,Mono-c-Si,0,295.0,271.6,1.627,,,60.0,9.73,39.4,9.2,32.1,0.008640240000000002,-0.11670280000000001,44.8,1.5965192951529483,9.73292594957677,1.855736099082673e-10,0.27746074074841054,922.6726902529563,15.67089811015673,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610P-295,Boviet Solar Technology Co Ltd,Multi-c-Si,0,295.0,273.2,1.627,,,60.0,9.66,39.5,9.22,32.0,0.0068392800000000005,-0.12102800000000001,43.7,1.5696518162950253,9.66000277835899,1.1377176902673556e-10,0.2875572989547463,999999.4931426917,7.694592410424986,-0.3958,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-300,Boviet Solar Technology Co Ltd,Mono-c-Si,0,300.0,276.3,1.627,,,60.0,9.84,39.5,9.32,32.2,0.00873792,-0.116999,44.8,1.5997055406120677,9.841523230210305,1.8554685147194735e-10,0.27282115772429333,1762.4135984830234,15.557817742185126,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-300-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,300.0,279.1,1.63,,,60.0,9.69,39.5,9.33,32.21,0.00504849,-0.11917150000000001,43.5,1.524906709095828,9.690002356990284,5.4537457004967186e-11,0.24316610804918382,999783.8029947701,3.2795073408012527,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-300-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,300.0,279.1,1.627,,,60.0,9.69,39.5,9.33,32.21,0.00504849,-0.11917150000000001,43.5,1.524906709095828,9.690002356990284,5.4537457004967186e-11,0.24316610804918382,999783.8029947701,3.2795073408012527,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-300,Boviet Solar Technology Co Ltd,Multi-c-Si,0,300.0,270.8,1.9403519999999999,1.956,0.992,72.0,8.79,45.3,8.12,36.5,0.005467379999999999,-0.15986369999999997,45.4,1.9319266059428346,8.809846760788295,5.602726904203442e-10,0.38809513560148223,171.884810070385,7.238995060185336,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-305,Boviet Solar Technology Co Ltd,Mono-c-Si,0,305.0,281.1,1.627,,,60.0,9.94,39.9,9.42,32.4,0.008826720000000001,-0.11818380000000002,44.8,1.6120571652213462,9.94078595747566,1.7689975341665655e-10,0.28849740104225263,3648.6291152748163,15.01306657714615,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-305-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,305.0,283.8,1.63,,,60.0,9.79,39.9,9.43,32.4,0.0051005899999999995,-0.12037830000000002,43.5,1.5381568433288906,9.790224749814518,5.3085376673392034e-11,0.2553036904301885,11120.923476638023,2.9705707587632078,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-305-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,305.0,283.8,1.627,,,60.0,9.79,39.9,9.43,32.4,0.0051005899999999995,-0.12037830000000002,43.5,1.5381568433288906,9.790224749814518,5.3085376673392034e-11,0.2553036904301885,11120.923476638023,2.9705707587632078,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-305,Boviet Solar Technology Co Ltd,Multi-c-Si,0,305.0,275.4,1.9403519999999999,1.956,0.992,72.0,9.05,45.6,8.16,37.4,0.005629100000000001,-0.1609224,45.4,1.993668562463311,9.08077376061129,9.941518140653664e-10,0.2801715951458923,82.39334731738569,12.171488333461008,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-310,Boviet Solar Technology Co Ltd,Mono-c-Si,0,310.0,285.8,1.627,,,60.0,10.04,40.1,9.51,32.6,0.00891552,-0.11877620000000001,44.8,1.6215537455106346,10.041333071976046,1.8245129372581924e-10,0.28241233672415317,2126.982731960508,15.210548169911924,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-310-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,310.0,288.6,1.63,,,60.0,9.89,40.1,9.52,32.62,0.005152690000000001,-0.12098170000000001,43.5,1.5466205812236908,9.890223216311314,5.4309871957364773e-11,0.25067118092731305,11106.44786990536,3.0756892315082034,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-310-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,310.0,288.6,1.627,,,60.0,9.89,40.1,9.52,32.62,0.005152690000000001,-0.12098170000000001,43.5,1.5466205812236908,9.890223216311314,5.4309871957364773e-11,0.25067118092731305,11106.44786990536,3.0756892315082034,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-310,Boviet Solar Technology Co Ltd,Mono-c-Si,0,310.0,280.5,1.9403519999999999,1.956,0.992,72.0,9.0,46.1,8.33,37.2,0.0037259999999999997,-0.1651763,45.7,1.9032231312975005,9.020485178517065,2.646596828287812e-10,0.3935068632909849,172.88411790308876,-0.540525270150336,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-310,Boviet Solar Technology Co Ltd,Multi-c-Si,0,310.0,280.0,1.9403519999999999,1.956,0.992,72.0,9.08,45.8,8.22,37.7,0.00564776,-0.16162819999999997,45.4,2.002040143432612,9.106611535989034,9.976648291774827e-10,0.26183822594124917,89.34062636589721,12.162196794937042,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-315,Boviet Solar Technology Co Ltd,Mono-c-Si,0,315.0,290.5,1.627,,,60.0,10.12,40.5,9.58,32.9,0.008986560000000001,-0.11996100000000001,44.8,1.6375366900323516,10.12184719553457,1.8325714273542096e-10,0.2860262683862233,1567.0163577123894,15.179505734657964,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-315-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,315.0,293.4,1.63,,,60.0,9.97,40.5,9.59,32.91,0.00519437,-0.12218850000000002,43.5,1.5607780218454157,9.97023232772324,5.360603674675993e-11,0.25850055343262884,11093.17879898096,2.9002860562738673,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-315L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,315.0,294.6,1.67,,,60.0,10.12,40.45,9.59,32.91,0.006142839999999999,-0.11459485000000001,43.1,1.5329305980249779,10.123934893841776,3.4932088862891065e-11,0.302309085783026,777.496990570644,5.679491538255876,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-315-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,315.0,293.4,1.627,,,60.0,9.97,40.5,9.59,32.91,0.00519437,-0.12218850000000002,43.5,1.5607780218454157,9.97023232772324,5.360603674675993e-11,0.25850055343262884,11093.17879898096,2.9002860562738673,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-315,Boviet Solar Technology Co Ltd,Mono-c-Si,0,315.0,285.2,1.9403519999999999,1.956,0.992,72.0,9.05,46.1,8.38,37.6,0.0037467000000000004,-0.1651763,45.7,1.9147730841855155,9.067852865268847,3.077851528163356e-10,0.33499693091050614,169.81713475076808,0.6334646410607018,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-315,Boviet Solar Technology Co Ltd,Multi-c-Si,0,315.0,288.1,1.9403519999999999,1.956,0.992,72.0,9.09,45.3,8.56,36.8,0.006199379999999999,-0.15623969999999998,45.1,1.845267747658514,9.095760454891538,1.9648418847519778e-10,0.35364183977533137,558.0470467063753,0.43551329011959444,-0.4123,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-320-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,320.0,298.2,1.63,,,60.0,10.0,41.0,9.62,33.33,0.00521,-0.12369700000000002,43.5,1.579991763776695,10.00000260270501,5.373690502536249e-11,0.26018997899679885,999777.1101294366,2.89445769652386,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-320L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,320.0,299.4,1.67,,,60.0,10.15,40.95,9.62,33.33,0.00616105,-0.11601135000000001,43.1,1.552079835554536,10.153801219798813,3.5160703978761825e-11,0.3035505714220943,810.5394132317574,5.709509738250388,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-320-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,320.0,298.2,1.627,,,60.0,10.0,41.0,9.62,33.33,0.00521,-0.12369700000000002,43.5,1.579991763776695,10.00000260270501,5.373690502536249e-11,0.26018997899679885,999777.1101294366,2.89445769652386,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-320,Boviet Solar Technology Co Ltd,Mono-c-Si,0,320.0,289.8,1.9403519999999999,1.956,0.992,72.0,9.08,46.3,8.46,37.8,0.0037591200000000003,-0.16589289999999998,45.7,1.9176257709337567,9.09318294463199,2.904761636799889e-10,0.33103237470929825,228.0047665803272,0.11798324008091653,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-320,Boviet Solar Technology Co Ltd,Multi-c-Si,0,320.0,295.6,1.94,1.956,0.992,72.0,9.17,45.5,8.65,37.0,0.006180580000000001,-0.1416415,43.6,1.8143079299367872,9.175349892177799,1.1685799718766973e-10,0.3564714017809755,611.0110190132976,6.726474987128083,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-325-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,325.0,302.9,1.63,,,60.0,10.05,41.5,9.71,33.53,0.005236050000000001,-0.12520550000000003,43.5,1.598028404057499,10.050002648651136,5.293628560454798e-11,0.2634720791645177,999799.0779683042,2.7284919016708944,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-325L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,325.0,304.2,1.67,,,60.0,10.2,41.45,9.71,33.53,0.0061914,-0.11742785000000001,43.1,1.5642325270347037,10.20001615053698,3.165109806831246e-11,0.3265615079219939,206245.51919771446,4.7556598152777125,-0.3627,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-325-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,325.0,303.0,1.627,,,60.0,10.05,41.5,9.71,33.53,0.005236050000000001,-0.12520550000000003,43.5,1.598028404057499,10.050002648651136,5.293628560454798e-11,0.2634720791645177,999799.0779683042,2.7284919016708944,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-325,Boviet Solar Technology Co Ltd,Mono-c-Si,0,325.0,296.5,1.9403519999999999,1.956,0.992,72.0,9.16,46.0,8.65,37.6,0.0044884,-0.14582,45.2,1.8597865814501378,9.163992776794885,1.6494626890224697e-10,0.3295040346818271,755.9293636285156,7.978074679500986,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-325,Boviet Solar Technology Co Ltd,Multi-c-Si,0,325.0,300.4,1.94,1.956,0.992,72.0,9.25,45.7,8.74,37.2,0.0062345000000000005,-0.1422641,43.6,1.8217599871012047,9.25401330870569,1.1724978946645005e-10,0.35002545358483406,806.7497777943504,6.67473567251268,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-330-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,330.0,307.7,1.63,,,60.0,10.11,41.95,9.8,33.74,0.00526731,-0.12656315,43.5,1.6145139620009494,10.1100026661649,5.253556686710796e-11,0.26364502237510495,999815.272288476,2.616179445573494,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-330L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,330.0,309.0,1.67,,,60.0,10.26,41.9,9.8,33.74,0.006227819999999999,-0.1187027,43.1,1.580385518307804,10.260003406080992,3.1398241499519226e-11,0.3319529193309603,999998.685185115,4.637772558933126,-0.3627,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-330-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,330.0,307.7,1.627,,,60.0,10.11,41.95,9.8,33.74,0.00526731,-0.12656315,43.5,1.6145139620009494,10.1100026661649,5.253556686710796e-11,0.26364502237510495,999815.272288476,2.616179445573494,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-330,Boviet Solar Technology Co Ltd,Mono-c-Si,0,330.0,301.2,1.9403519999999999,1.956,0.992,72.0,9.26,46.2,8.76,37.7,0.0045374000000000005,-0.146454,45.2,1.864432591366244,9.26262497772321,1.5967407410358086e-10,0.3359992930762879,1185.2878754853207,7.594193886906512,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-330,Boviet Solar Technology Co Ltd,Multi-c-Si,0,330.0,305.1,1.94,1.956,0.992,72.0,9.33,45.8,8.83,37.4,0.00628842,-0.1425754,43.6,1.8274326073989684,9.332786478243126,1.2122508447166227e-10,0.33217754514196274,1112.2344500785396,6.883324295541674,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-335L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,335.0,313.8,1.67,,,60.0,10.32,42.35,9.89,33.94,0.00626424,-0.11997755000000002,43.1,1.5963699654453387,10.320003482870728,3.1067523315874886e-11,0.3373640886717633,999704.4420344081,4.4985917364460155,-0.3627,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-W5-335-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,335.0,312.5,1.627,,,60.0,10.17,42.4,9.89,33.94,0.00529857,-0.1279208,43.5,1.630811128318652,10.170002911015718,5.1993933376499465e-11,0.26301856719136607,918277.4042858104,2.4814012641727845,-0.3798,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-335,Boviet Solar Technology Co Ltd,Mono-c-Si,0,335.0,307.2,1.94,,,72.0,9.35,46.4,8.84,37.9,0.005423,-0.155904,45.1,1.8610707923062961,9.353416468459057,1.3829803355816098e-10,0.3323860000611358,909.6554139545929,0.12127831391052768,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-335,Boviet Solar Technology Co Ltd,Multi-c-Si,0,335.0,309.8,1.94,1.956,0.992,72.0,9.41,46.1,8.92,37.6,0.00634234,-0.1435093,43.6,1.8367107635868956,9.41145825597069,1.1809406995357248e-10,0.3375066250413578,2177.9017844589644,6.577627653698836,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-340,Boviet Solar Technology Co Ltd,Mono-c-Si,0,340.0,313.2,1.94,,,72.0,9.45,46.6,8.93,38.1,0.006615000000000001,-0.141431,44.9,1.8514706848767466,9.454293231833374,1.1011222904761884e-10,0.32997396707700527,726.3186331425188,8.669187069627283,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-340,Boviet Solar Technology Co Ltd,Multi-c-Si,0,340.0,314.6,1.94,1.956,0.992,72.0,9.49,46.5,9.0,37.8,0.00639626,-0.1447545,43.6,1.8471631332022336,9.4900093608324,1.1077592704133057e-10,0.3543249460618255,359230.11758101283,5.949011159217143,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-345,Boviet Solar Technology Co Ltd,Mono-c-Si,0,345.0,318.0,1.94,,,72.0,9.5,47.0,8.99,38.4,0.0066500000000000005,-0.142645,44.9,1.865316870954897,9.503163073283899,1.0786946784368489e-10,0.3346648786338271,1005.1353370739424,8.436633560692869,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-345,Boviet Solar Technology Co Ltd,Multi-c-Si,0,345.0,319.3,1.94,1.956,0.992,72.0,9.57,46.8,9.09,38.0,0.006450180000000001,-0.1456884,43.6,1.8592796498803383,9.570004261359891,1.1201244811013503e-10,0.3587414423054915,805759.6945095882,5.972163569592911,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-350,Boviet Solar Technology Co Ltd,Mono-c-Si,0,350.0,322.7,1.94,,,72.0,9.59,47.2,9.1,38.5,0.006713,-0.14325200000000002,44.9,1.8673440337461884,9.590008290191776,1.0100685231463004e-10,0.34158486325380955,394856.4647291342,7.764952468657431,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-350,Boviet Solar Technology Co Ltd,Multi-c-Si,0,350.0,324.1,1.94,,,72.0,9.65,47.0,9.17,38.2,0.0065041000000000005,-0.14631100000000002,43.6,1.8684140930511626,9.650004296022615,1.1477228653698979e-10,0.35239000988860464,791670.3050854404,6.109425820898533,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-355S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,355.0,333.9,1.85,,,60.0,11.29,40.02,10.7,33.23,0.00549823,-0.12326160000000001,42.8,1.4847358874181205,11.29572525639329,2.2029328726973643e-11,0.2054850325228029,405.2090728224619,-7.081900283329956,-0.3406,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-355S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,355.0,333.4,1.87,,,60.0,11.29,40.02,10.7,33.23,0.00569016,-0.11921958000000002,42.8,1.4984466164987666,11.295342984013017,2.820348600013343e-11,0.20266548339238163,428.2425972933566,-1.9937891187246726,-0.3486,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-355S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,355.0,334.4,1.87,,,60.0,11.29,40.02,10.7,33.23,0.0062095,-0.10389192000000001,42.7,1.4688977472777167,11.296178032639997,1.646499244079416e-11,0.2087542780443389,381.48646343006806,7.705913146966637,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-355,Boviet Solar Technology Co Ltd,Mono-c-Si,0,355.0,327.4,1.94,,,72.0,9.67,47.4,9.2,38.6,0.006769000000000002,-0.143859,44.9,1.8758457394326344,9.670004277123518,1.0266192505032963e-10,0.34736188539348384,785432.5581093832,7.834210287307397,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612P-355,Boviet Solar Technology Co Ltd,Multi-c-Si,0,355.0,328.8,1.94,,,72.0,9.73,47.3,9.25,38.4,0.006558020000000001,-0.1472449,43.6,1.879685979521827,9.730004431618612,1.147150972783157e-10,0.35708637435875035,784121.1326264896,6.03437315435916,-0.3986,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-360S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,360.0,338.7,1.85,,,60.0,11.37,40.21,10.78,33.45,0.00553719,-0.1238468,42.8,1.4929562203943945,11.375384072483264,2.2665840218772496e-11,0.1983861859820066,418.9488486926719,-6.921254910782006,-0.3406,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-360S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,360.0,338.2,1.87,,,60.0,11.37,40.21,10.78,33.45,0.00573048,-0.11978559,42.8,1.5067398976963309,11.37501321402194,2.901122132154149e-11,0.19556910107939474,443.551923569047,-1.8264787381201777,-0.3486,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-360S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,360.0,339.2,1.87,,,60.0,11.37,40.21,10.78,33.45,0.0062534999999999995,-0.10438516,42.7,1.4769752101523466,11.375825316161475,1.692735812885301e-11,0.2016646133333223,393.6141172154965,7.885902400574518,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-360,Boviet Solar Technology Co Ltd,Mono-c-Si,0,360.0,332.2,1.94,,,72.0,9.83,47.5,9.29,38.8,0.006881000000000001,-0.1441625,44.9,1.88618534569491,9.83437877234341,1.1298083724596526e-10,0.3278524980525313,736.0031938824154,8.54809063030562,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-360-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,360.0,334.8,1.94,,,72.0,9.68,47.5,9.29,38.82,0.0037655199999999996,-0.1426425,43.5,1.8132628540255216,9.680249244786902,4.0642916321630606e-11,0.3059086045393879,11880.67871206416,1.5080657480454442,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-360-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,360.0,334.8,1.94,,,72.0,9.68,47.5,9.29,38.82,0.0037655199999999996,-0.1426425,43.5,1.8132628540255216,9.680249244786902,4.0642916321630606e-11,0.3059086045393879,11880.67871206416,1.5080657480454442,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-365S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,365.0,343.5,1.85,,,60.0,11.46,40.38,10.87,33.63,0.005581020000000001,-0.12437040000000002,42.8,1.499851611556159,11.465048639600754,2.3094961199386732e-11,0.19360692618690722,439.47193375081696,-6.840431526367547,-0.3406,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-365S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,365.0,343.0,1.87,,,60.0,11.46,40.38,10.87,33.63,0.005775840000000001,-0.12029202000000001,42.8,2.3310973521972453,11.460022831876083,1.2336947192193984e-08,0.8164859189200104,422221.77283443796,-87.00224413674798,-0.3486,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-365S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,365.0,344.0,1.87,,,60.0,11.46,40.38,10.87,33.63,0.0063030000000000004,-0.10482648000000001,42.7,1.47507182505552,11.460006193412777,1.4804580252999285e-11,0.19850276325883592,367303.4119813395,6.615906285865482,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-365,Boviet Solar Technology Co Ltd,Mono-c-Si,0,365.0,336.9,1.94,,,72.0,9.94,47.6,9.39,38.9,0.006958000000000001,-0.144466,44.9,1.8910427272057309,9.944786380265866,1.1553823915272176e-10,0.32260322445969536,669.9585527074129,8.648690473760979,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-365-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,365.0,339.5,1.94,,,72.0,9.79,47.6,9.4,38.9,0.003808309999999999,-0.1429428,43.5,1.8174235764367017,9.790249515973267,4.130871865868798e-11,0.30083238091063336,11803.456442548666,1.5485555007561929,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-365-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,365.0,339.5,1.94,,,72.0,9.79,47.6,9.4,38.9,0.003808309999999999,-0.1429428,43.5,1.8174235764367017,9.790249515973267,4.130871865868798e-11,0.30083238091063336,11803.456442548666,1.5485555007561929,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-370S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,370.0,348.4,1.85,,,60.0,11.54,40.56,10.96,33.81,0.005619979999999999,-0.1249248,42.8,1.506279653205236,11.544064530250681,2.3182312888962398e-11,0.1900650234931882,539.6319567044713,-6.868903252320141,-0.3406,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-370S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,370.0,347.8,1.87,,,60.0,11.54,40.56,10.96,33.81,0.005816159999999999,-0.12082824,42.8,1.5201844208633184,11.543717713855688,2.9669698951462115e-11,0.18726678097695462,581.2869926456897,-1.7719753300754422,-0.3486,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-370S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,370.0,348.9,1.87,,,60.0,11.54,40.56,10.96,33.81,0.006346999999999999,-0.10529376,42.7,1.4901381972908188,11.54447846323127,1.7308517217454477e-11,0.19332557053590307,498.1567923902952,7.944403171890099,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-370,Boviet Solar Technology Co Ltd,Mono-c-Si,0,370.0,341.6,1.94,,,72.0,10.04,47.7,9.49,39.0,0.0070279999999999995,-0.1447695,44.9,1.894944312502766,10.044341691295157,1.1666481556198628e-10,0.317853439522513,735.0243700171645,8.643990167185008,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-370-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,370.0,344.3,1.94,,,72.0,9.89,47.7,9.5,39.02,0.0038472099999999998,-0.1432431,43.5,1.7397830339740707,9.890177484179784,1.2244555383748058e-11,0.3206052338385493,17865.180405697538,99.99999901223994,-0.3824,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-370-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,370.0,344.3,1.94,,,72.0,9.89,47.7,9.5,39.02,0.0038472099999999998,-0.1432431,43.5,1.7397830339740707,9.890177484179784,1.2244555383748058e-11,0.3206052338385493,17865.180405697538,99.99999901223994,-0.3824,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-375S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,375.0,353.2,1.85,,,60.0,11.62,40.75,11.06,33.96,0.00565894,-0.12551,42.8,1.5115210027363966,11.62240727286762,2.2658627532527293e-11,0.1906887560407504,920.4620894867236,-7.101310939301761,-0.3406,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-375S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,375.0,352.6,1.87,,,60.0,11.62,40.75,11.06,33.96,0.00585648,-0.12139425000000001,42.8,1.5254771195988097,11.622080286419049,2.900962945709945e-11,0.18790737515472597,1049.6072926595402,-2.01402440433673,-0.3486,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-375S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,375.0,353.7,1.87,,,60.0,11.62,40.75,11.06,33.96,0.006391,-0.105787,42.7,1.4954051040613148,11.622796074077874,1.6936791839466662e-11,0.19391259480438747,805.867204084632,7.6838151128505725,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375,Boviet Solar Technology Co Ltd,Mono-c-Si,0,375.0,346.4,1.94,,,72.0,10.11,48.0,9.57,39.2,0.007077,-0.14568,44.9,1.9042803069657097,10.113105243194388,1.1374511711609211e-10,0.32325628700027337,1052.452707652939,8.354794204303664,-0.3924,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,375.0,349.1,1.94,,,72.0,9.96,48.0,9.58,39.22,0.00387444,-0.144144,43.5,1.833975007744687,9.960243950766602,4.280082629376545e-11,0.2896255151387253,11824.81224580355,1.6981333092744473,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,375.0,349.1,1.99,,,72.0,10.11,47.95,9.58,39.22,0.00529764,-0.13603415000000002,43.3,1.846783955297674,10.113530881972476,5.329168225545878e-11,0.32805813495817143,939.3313120681607,9.312805994036577,-0.3825,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,375.0,349.4,2.01,,,72.0,10.11,47.95,9.58,39.22,0.00512577,-0.14006195000000002,43.3,1.837451302285544,10.113750599929567,4.669540159959429e-11,0.33014754182532624,889.9354568757154,5.043055002009159,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,375.0,350.9,2.02,,,72.0,10.11,47.95,9.58,39.22,0.00173892,-0.14078120000000002,42.7,1.752380102625629,10.115875991797811,1.3123778367282678e-11,0.34938359655787427,601.1356608024242,-5.247414587820877,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,375.0,350.4,2.03,,,72.0,10.11,47.95,9.58,39.22,0.00356883,-0.14197995,43.1,1.7870482807210382,10.114982968807888,2.233641089859287e-11,0.3415026437552963,692.8784683997484,-2.1758423234099533,-0.3662,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,375.0,350.7,2.05,,,72.0,10.11,47.95,9.58,39.22,0.00321498,-0.140014,42.9,1.7758444668901956,10.115267490782783,1.885209124778882e-11,0.34404317300996423,660.3289304298862,-2.0987380396594966,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-375L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,375.0,350.9,2.05,,,72.0,10.11,47.95,9.58,39.22,0.00167826,-0.13219815000000001,42.8,1.7397598734193174,10.116210384016256,1.0757311137709405e-11,0.3522670868544244,573.4621692296116,-0.6806766917363609,-0.3629,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-375-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,375.0,349.1,1.94,,,72.0,9.96,48.0,9.58,39.22,0.00387444,-0.144144,43.5,1.833975007744687,9.960243950766602,4.280082629376545e-11,0.2896255151387253,11824.81224580355,1.6981333092744473,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,380.0,358.0,1.85,,,60.0,11.73,40.94,11.14,34.17,0.0057125100000000005,-0.1260952,42.8,1.5157305337349294,11.730007000186243,2.1825567338791763e-11,0.18528142277702028,310473.55929845123,-7.465015581995542,-0.3406,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,380.0,357.4,1.87,,,60.0,11.73,40.94,11.14,34.17,0.00591192,-0.12196026,42.8,1.5354715783295045,11.733791288131204,3.0705515122717335e-11,0.18148590238583262,561.5056439305594,-1.6282849664783021,-0.3486,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,380.0,358.5,1.87,,,60.0,11.73,40.94,11.14,34.17,0.0064515,-0.10628024,42.7,1.5050781585899653,11.734551904185148,1.790477761414942e-11,0.18752125887973795,483.2316994877967,8.09915656686118,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,380.0,353.9,1.94,,,72.0,10.04,48.3,9.66,39.41,0.0039055599999999993,-0.1450449,43.5,1.8445519365806728,10.040249526477332,4.2605982772988e-11,0.2934907533214568,11808.963614938466,1.595239042872024,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,380.0,353.9,1.99,,,72.0,10.19,48.25,9.66,39.41,0.00533956,-0.13688524999999999,43.3,1.8565761887625643,10.193127016946178,5.244051726716013e-11,0.3341881473060601,1089.0176957794113,9.098981219042662,-0.3825,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,380.0,354.2,2.01,,,72.0,10.19,48.25,9.66,39.41,0.005166329999999999,-0.14093825000000001,43.3,1.8471857212843563,10.19335045617783,4.5938372563037346e-11,0.33627066919932186,1022.7259186760516,4.835508882994742,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,380.0,355.7,2.02,,,72.0,10.19,48.25,9.66,39.41,0.0017526799999999997,-0.141662,42.7,1.7617561077483528,10.195506541457208,1.291385425280574e-11,0.35540554023840937,657.6872918722482,-5.433344307547954,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,380.0,355.1,2.03,,,72.0,10.19,48.25,9.66,39.41,0.0035970699999999995,-0.14286824999999997,43.1,1.796548866758464,10.194601393228611,2.1969673931497847e-11,0.3475708773842429,769.711947902667,-2.3710139292712595,-0.3662,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,380.0,355.4,2.05,,,72.0,10.19,48.25,9.66,39.41,0.00324042,-0.14089,42.9,1.7853000774568646,10.194889936964953,1.8543707376915136e-11,0.35009755111409185,729.5581477510439,-2.2936914128140082,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-380L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,380.0,355.7,2.05,,,72.0,10.19,48.25,9.66,39.41,0.0016915399999999998,-0.13302524999999998,42.8,1.7490762156109336,10.195845787409745,1.0584646908456572e-11,0.35827532294306513,624.5224691882004,-0.8763376548299174,-0.3629,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-380-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,380.0,353.9,1.94,,,72.0,10.04,48.3,9.66,39.41,0.0039055599999999993,-0.1450449,43.5,1.8445519365806728,10.040249526477332,4.2605982772988e-11,0.2934907533214568,11808.963614938466,1.595239042872024,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,385.0,358.6,1.94,,,72.0,10.11,48.5,9.74,39.6,0.003932789999999999,-0.1456455,43.5,1.8538155429937426,10.11024142144021,4.389966902219792e-11,0.2825357062667812,11831.748842971447,1.783394352304789,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,385.0,358.7,1.99,,,72.0,10.26,48.45,9.74,39.6,0.00537624,-0.13745265,43.3,1.8636662853951032,10.261902728751881,5.243950708013704e-11,0.33015412216341355,1780.275707447867,9.032973581879382,-0.3825,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,385.0,358.9,2.01,,,72.0,10.26,48.45,9.74,39.6,0.00520182,-0.14152245000000002,43.3,1.854237583063873,10.26211827165147,4.593394617632249e-11,0.3322283846419946,1609.1720873109045,4.771414792946829,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,385.0,360.4,2.02,,,72.0,10.26,48.45,9.74,39.6,0.00176472,-0.14224920000000002,42.7,1.7684862647768658,10.264201348038732,1.2908094183548837e-11,0.3512815440905476,857.8553080239259,-5.494658469229694,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,385.0,359.9,2.03,,,72.0,10.26,48.45,9.74,39.6,0.00362178,-0.14346045,43.1,1.8034156237526837,10.26332579413169,2.196490308800328e-11,0.34347909505335694,1059.6253095962502,-2.4320519817396797,-0.3662,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,385.0,360.2,2.05,,,72.0,10.26,48.45,9.74,39.6,0.00326268,-0.14147400000000002,42.9,1.792127373522149,10.263604652913251,1.8539648221842242e-11,0.345994329651373,984.8110249214751,-2.3549185613070063,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-385L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,385.0,360.5,2.05,,,72.0,10.26,48.45,9.74,39.6,0.00170316,-0.13357665000000002,42.8,1.7557761676539858,10.264529287395977,1.0582274750403422e-11,0.3541351275866731,802.2070913449435,-0.938996657468068,-0.3629,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-385-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,385.0,358.6,1.94,,,72.0,10.11,48.5,9.74,39.6,0.003932789999999999,-0.1456455,43.5,1.8538155429937426,10.11024142144021,4.389966902219792e-11,0.2825357062667812,11831.748842971447,1.783394352304789,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,390.0,363.4,1.94,,,72.0,10.18,48.7,9.82,39.79,0.00396002,-0.14624610000000002,43.5,1.8630753404563651,10.180233338049197,4.5217713390461126e-11,0.2715632045122349,11847.682837964376,1.9695658353839252,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,390.0,363.5,1.99,,,72.0,10.33,48.65,9.82,39.79,0.005412920000000001,-0.13802005,43.3,1.8707661443592136,10.330703502456691,5.2445234963678395e-11,0.3261823466749724,4789.556706449507,8.968605859770324,-0.3825,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,390.0,363.7,2.01,,,72.0,10.33,48.65,9.82,39.79,0.00523731,-0.14210665,43.3,1.85963007409501,10.330007440161245,4.492285865112576e-11,0.32857678929716166,456206.89246973046,4.516603473588821,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,390.0,365.2,2.02,,,72.0,10.33,48.65,9.82,39.79,0.00177676,-0.1428364,42.7,1.775240194963263,10.332921034016925,1.2907030079133973e-11,0.3472181716382488,1227.9088888370507,-5.55274230386301,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,390.0,364.7,2.03,,,72.0,10.33,48.65,9.82,39.79,0.00364649,-0.14405264999999998,43.1,1.8066803631085082,10.33000770836568,2.086814169676147e-11,0.34017007483182404,455870.15934092615,-2.9024909861574892,-0.3662,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,390.0,365.0,2.05,,,72.0,10.33,48.65,9.82,39.79,0.00328494,-0.142058,42.9,1.798963967374879,10.332344687503795,1.8538077920535796e-11,0.34195460990682,1506.5509948047352,-2.41462194513911,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-390L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,390.0,365.3,2.05,,,72.0,10.33,48.65,9.82,39.79,0.0017147800000000002,-0.13412805,42.8,1.7624956544629264,10.333236910888935,1.0583100462945483e-11,0.3500567267313971,1117.1410617654399,-0.9987622126513876,-0.3629,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-390-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,390.0,363.4,1.94,,,72.0,10.18,48.7,9.82,39.79,0.00396002,-0.14624610000000002,43.5,1.8630753404563651,10.180233338049197,4.5217713390461126e-11,0.2715632045122349,11847.682837964376,1.9695658353839252,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-395-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,395.0,368.2,1.94,,,72.0,10.27,48.9,9.9,39.98,0.00399503,-0.1468467,43.5,1.8707041423335322,10.270235668127837,4.560323320627626e-11,0.2713469157372669,11824.826101818264,1.9669960038454917,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-395L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,395.0,368.3,1.99,,,72.0,10.42,48.85,9.9,39.97,0.00546008,-0.13858745000000003,43.3,1.8793701156600278,10.421247015447573,5.3537208042653007e-11,0.3227507684474455,2696.8901896444972,9.076148641247071,-0.3825,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-395L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,395.0,368.5,2.01,,,72.0,10.42,48.85,9.9,39.97,0.00528294,-0.14269085000000004,43.3,1.8698644818261287,10.42145811539801,4.6898171127164516e-11,0.3248094756218822,2321.1573440321367,4.813383450802995,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-395L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,395.0,370.0,2.02,,,72.0,10.42,48.85,9.9,39.97,0.00179224,-0.14342360000000004,42.7,1.7833674285125245,10.423503590502749,1.3177222415267015e-11,0.34372983807454704,1022.2841337309825,-5.458283486259194,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-395L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,395.0,369.5,2.03,,,72.0,10.42,48.85,9.9,39.97,0.00367826,-0.14464485,43.1,1.8186051459050077,10.422642976489803,2.2425781658179818e-11,0.3359807662483416,1324.6125064956861,-2.3932234431901778,-0.3662,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-395L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,395.0,370.1,2.05,,,72.0,10.42,48.85,9.9,39.97,0.0017297200000000001,-0.13467945,42.8,1.7705461806577458,10.42382616528512,1.0802539421321176e-11,0.3465636692859134,943.8153432411518,-0.9011243760162164,-0.3629,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-395-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,395.0,368.2,1.94,,,72.0,10.27,48.9,9.9,39.98,0.00399503,-0.1468467,43.5,1.8707041423335322,10.270235668127837,4.560323320627626e-11,0.2713469157372669,11824.826101818264,1.9669960038454917,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,400.0,373.0,1.94,,,72.0,10.3,49.2,9.98,40.16,0.0040067,-0.1477476,43.5,1.8851751792987455,10.30022913417104,4.7674102564579485e-11,0.24798915052217402,11147.57238462696,2.308496159587494,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,400.0,373.0,1.99,,,72.0,10.45,49.15,9.98,40.16,0.0054758,-0.13943855,43.3,1.8916780291119455,10.450003269880078,5.4347353218318414e-11,0.3128829874031825,999999.6963296891,9.17743987857376,-0.3825,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,400.0,373.3,2.01,,,72.0,10.45,49.15,9.98,40.16,0.00529815,-0.14356715,43.3,1.8817270322207342,10.450003302173506,4.7370329051206535e-11,0.31597567876378835,999999.697514946,4.867445608637892,-0.3777,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,400.0,374.8,2.02,,,72.0,10.45,49.15,9.98,40.16,0.0017974,-0.1443044,42.7,1.7915425583757814,10.450005330789866,1.2719779779945319e-11,0.35065821750715187,687409.1312083657,-5.7649926421128015,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,400.0,374.3,2.03,,,72.0,10.45,49.15,9.98,40.16,0.0036888499999999996,-0.14553314999999997,43.1,1.8281268232966512,10.450005212197869,2.2024896607703063e-11,0.34273210568849277,687165.531927962,-2.569234083169239,-0.3662,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,400.0,374.6,2.05,,,72.0,10.45,49.15,9.98,40.16,0.0033231000000000003,-0.14351799999999998,42.9,1.8162826025887004,10.450005251062688,1.8482972920995835e-11,0.34529139718618723,687170.4290164857,-2.5392553100671558,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-400L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,400.0,374.9,2.05,,,72.0,10.45,49.15,9.98,40.16,0.0017347,-0.13550655,42.8,1.7782116802977515,10.450005371948093,1.0355190596573717e-11,0.35356196173712834,687789.6371003141,-1.2803009307862177,-0.3629,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-W5-400-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,400.0,373.0,1.94,,,72.0,10.3,49.2,9.98,40.16,0.0040067,-0.1477476,43.5,1.8851751792987455,10.30022913417104,4.7674102564579485e-11,0.24798915052217402,11147.57238462696,2.308496159587494,-0.3824,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-405L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,405.0,377.8,1.99,,,72.0,10.49,49.45,10.06,40.33,0.005496760000000001,-0.14028965000000002,43.3,1.9051756185917073,10.490004165018618,5.602652736056863e-11,0.30158030834237964,759593.9814732552,9.412265105757477,-0.3825,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,405.0,378.1,2.01,,,72.0,10.49,49.45,10.06,40.33,0.005318430000000001,-0.14444345000000003,43.3,1.8951637356160298,10.490003202036462,4.8847677365976085e-11,0.3047648247389031,998488.8520405771,5.09539078062805,-0.3777,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,405.0,379.6,2.02,,,72.0,10.49,49.45,10.06,40.33,0.0018042800000000001,-0.14518520000000004,42.7,1.8040727171030013,10.49000350054712,1.3081981516049587e-11,0.3336901545476106,999983.0266688714,-5.580106761936364,-0.3673,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,405.0,379.1,2.03,,,72.0,10.49,49.45,10.06,40.33,0.00370297,-0.14642145,43.1,1.8411206348573028,10.4900033794803,2.2709813592464715e-11,0.32192584183310713,999302.0125504948,-2.3580202014104357,-0.3662,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,405.0,379.4,2.05,,,72.0,10.49,49.45,10.06,40.33,0.0033358200000000006,-0.144394,42.9,1.8291399413524927,10.490003417080388,1.9046352099029884e-11,0.32573023539603163,999980.706984241,-2.332606207233437,-0.3645,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,405.0,379.7,2.05,,,72.0,10.49,49.45,10.06,40.33,0.00174134,-0.13633365,42.8,1.790643336161762,10.49000354545081,1.0651131208366842e-11,0.337954558576085,999932.0206568242,-1.0855016699867244,-0.3629,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-410L-H,Boviet Solar Technology Co Ltd,Mono-c-Si,0,410.0,382.6,1.99,,,72.0,10.51,49.75,10.14,40.5,0.00550724,-0.14114075,43.3,1.9208943988397746,10.510247522950335,5.935730137735047e-11,0.27656412689440163,11743.118709141907,9.908020496781456,-0.3825,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-410L-H-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,410.0,382.9,2.01,,,72.0,10.51,49.75,10.14,40.5,0.00532857,-0.14531975000000003,43.3,1.9108298789762554,10.510250169984557,5.178815203159957e-11,0.2798969652515427,11758.881812738939,5.577603535639018,-0.3777,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-410L-H-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,410.0,384.4,2.02,,,72.0,10.51,49.75,10.14,40.5,0.00180772,-0.146066,42.7,1.8181229059987445,10.510003436515612,1.3735133616933928e-11,0.31216053621757567,954708.7930176362,-5.222332559695152,-0.3673,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-410L-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,410.0,383.9,2.03,,,72.0,10.51,49.75,10.14,40.5,0.0037100299999999996,-0.14730975,43.1,1.8556570403109665,10.510003310612776,2.3889348565228193e-11,0.2997723972963425,951699.159637589,-1.972913533491641,-0.3662,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-410L-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,410.0,384.2,2.05,,,72.0,10.51,49.75,10.14,40.5,0.00334218,-0.14526999999999998,42.9,1.8435332842956187,10.510003351336998,2.002779025622004e-11,0.30377384277647446,952679.4272121603,-1.9503324515890992,-0.3645,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-410L-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,410.0,384.5,2.05,,,72.0,10.51,49.75,10.14,40.5,0.00174466,-0.13716075,42.8,1.8045450469687911,10.510003481781553,1.117934556540998e-11,0.3166419076322392,955821.333036987,-0.7126722390234925,-0.3629,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-410-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,410.0,388.3,2.16,,,54.0,13.42,38.28,12.74,32.2,0.00452254,-0.08218716000000001,43.1,1.310838518869216,13.428365369956081,2.755784051870144e-12,0.14888854429182838,238.85187116988175,11.36209080706719,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-410-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,410.0,388.2,2.16,,,54.0,13.42,38.28,12.74,32.2,0.006052420000000001,-0.07835916,43.1,1.3246035049111176,13.42789699458601,3.734514701482941e-12,0.14641275033048534,248.81099910988078,19.64002408547655,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-410-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,410.0,388.3,2.16,,,54.0,13.42,38.28,12.74,32.2,0.005797440000000001,-0.0811536,43.1,1.3235710178185138,13.427931712355944,3.651144392391252e-12,0.14659812789324958,248.03558064691077,15.301085689759791,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-415-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,415.0,393.2,2.16,,,54.0,13.51,38.47,12.83,32.37,0.00455287,-0.08259509,43.1,1.31732758910645,13.518086507518065,2.7742798978471644e-12,0.14774914627599428,246.84215830643214,11.3603903505013,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,415.0,393.1,2.16,,,54.0,13.51,38.47,12.83,32.37,0.00609301,-0.07874808999999999,43.1,1.3311611713055465,13.517621880082379,3.759632217189495e-12,0.1452781143173352,257.50960482330555,19.638398667802377,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-415-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,415.0,393.1,2.16,,,54.0,13.51,38.47,12.83,32.37,0.00583632,-0.0815564,43.1,1.3301235185256561,13.517656315537783,3.675695736872546e-12,0.14546313896396645,256.677902214066,15.299506420451173,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-420-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,420.0,398.0,2.16,,,54.0,13.6,38.66,12.91,32.54,0.004583200000000001,-0.08300302,43.1,1.324266109745155,13.608468138467563,2.8180484653681175e-12,0.1465871914842675,235.4219660463653,11.44582587059089,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-420-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,420.0,397.9,2.16,,,54.0,13.6,38.66,12.91,32.54,0.0061336,-0.07913702,43.1,1.3381675046619714,13.607996675298859,3.818147796380023e-12,0.14411863597743785,245.103543591052,19.72793115230194,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-420-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,420.0,398.0,2.16,,,54.0,13.6,38.66,12.91,32.54,0.0058752000000000006,-0.0819592,43.1,1.337129195647138,13.608031471812817,3.7333207683083525e-12,0.14430268993533557,244.3532931687778,15.386827092559807,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-425S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,425.0,397.9,2.2,,,72.0,11.28,48.1,10.71,39.76,0.00288768,-0.14001910000000004,42.9,1.7760653741968775,11.284340451598718,1.9412982207755426e-11,0.26714582780984475,694.2607074888941,-2.3496075001903693,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-425S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,425.0,397.9,2.23,,,72.0,11.28,48.1,10.71,39.76,0.0024928800000000003,-0.14559870000000003,42.8,1.7662257019166094,11.28001678059227,1.679057457853503e-11,0.2690223716538215,180839.04260918483,-7.171464114261677,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-425S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,425.0,398.1,2.23,,,72.0,11.28,48.1,10.71,39.76,0.00284256,-0.1474746,42.8,1.775064379532223,11.280017965334183,1.9229005147215704e-11,0.26721200753684426,167776.7757298854,-7.387472083862766,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-425-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,425.0,402.8,2.16,,,54.0,13.69,38.85,13.0,32.71,0.00461353,-0.08341095,43.1,1.3307554852260115,13.698192080376302,2.8366032544185627e-12,0.14547859336859423,243.11308659410832,11.443789789287466,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-425-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,425.0,402.7,2.16,,,54.0,13.69,38.85,13.0,32.71,0.0061741899999999995,-0.07952595,43.1,1.3447254739932626,13.697724372080085,3.843343828818667e-12,0.14301468827926797,253.46669810097154,19.72595102452735,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-425-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,425.0,402.8,2.16,,,54.0,13.69,38.85,13.0,32.71,0.00591408,-0.082362,43.1,1.3436820019267952,13.697758887594988,3.75794976316812e-12,0.14319840249957327,252.6632986562299,15.384901760234788,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-425-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,425.0,399.3,2.1,,,60.0,13.21,40.73,12.39,34.37,0.00236459,-0.33700002,42.9,2.1785108023881876,13.210220611478755,9.999999895622052e-08,0.018229097225956052,1091.598379562485,-32.033075357185865,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,425.0,401.0,2.1,,,60.0,13.21,40.7,12.39,34.4,0.0113606,-0.115588,42.8,1.5657782155968547,13.22079766838225,6.650883302980368e-11,0.11557125213847973,141.3912895192138,8.418800961917498,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,425.0,399.5,2.1,,,60.0,13.21,40.73,12.39,34.37,0.006182280000000001,-0.10744573999999998,43.0,1.5272806217879349,13.222514196347904,3.383551787187562e-11,0.12769924341177905,134.7994683640605,11.095728165291321,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-430S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,430.0,402.7,2.2,,,72.0,11.34,48.25,10.78,39.96,0.00290304,-0.14045575000000002,42.9,1.7822945466444535,11.343325644798139,1.974636688645087e-11,0.2585156329480024,881.5034453105264,-2.261545519586908,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-430S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,430.0,402.7,2.23,,,72.0,11.34,48.25,10.78,39.96,0.00250614,-0.14605275,42.8,1.7753421826754618,11.340030421277918,1.7840245593798943e-11,0.2598239334628641,96853.6157299364,-6.755668386255367,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-430S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,430.0,402.9,2.23,,,72.0,11.34,48.25,10.78,39.96,0.00285768,-0.1479345,42.8,1.7843215554262855,11.340013269814499,2.045544602847307e-11,0.2579952829136193,220476.72480633875,-6.963928394077336,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-430-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,430.0,407.7,2.16,,,54.0,13.78,39.04,13.08,32.88,0.0046438600000000005,-0.08381888000000001,43.1,1.3376934516688437,13.788567982563531,2.8806793138353125e-12,0.14434584762087166,232.1533415810189,11.527883784471396,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,430.0,407.6,2.16,,,54.0,13.78,39.04,13.08,32.88,0.0062147800000000005,-0.07991488000000001,43.1,1.351731206418115,13.788093443682085,3.902256371499692e-12,0.14188435289610044,241.57410158444432,19.814067328713946,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-430-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,430.0,407.6,2.16,,,54.0,13.78,39.04,13.08,32.88,0.00595296,-0.0827648,43.1,1.3506870851094712,13.788128318821585,3.8159722252754625e-12,0.14206711512617431,240.84744861222637,15.4708437646233,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-430-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,430.0,404.1,2.1,,,60.0,13.26,40.97,12.46,34.57,0.00237354,-0.33898578,42.9,1.5210102007714694,13.271836475004202,2.6032503034280772e-11,0.13091124319277458,146.6554106441719,-65.27503755541069,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-430-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,430.0,405.9,2.1,,,60.0,13.26,41.0,12.46,34.6,0.011403599999999998,-0.11644,42.8,1.574545146509655,13.270108832763682,6.392085433946739e-11,0.12121211790368504,158.9968633512469,8.028842439588564,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-430-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,430.0,404.3,2.1,,,60.0,13.26,40.97,12.46,34.57,0.00620568,-0.10807886,43.0,1.5348036399816603,13.271374730410432,3.317601196118079e-11,0.1284312934691884,149.71774275551377,10.876626953869593,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,435.0,407.5,2.2,,,72.0,11.42,48.45,10.85,40.17,0.00292352,-0.14103795000000002,42.9,1.7911650030413822,11.423832637131227,2.0320851743316128e-11,0.2530324734739732,753.953690272884,-2.087798828942653,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,435.0,407.4,2.23,,,72.0,11.42,48.45,10.85,40.17,0.00252382,-0.14665815000000001,42.8,1.7887209473557815,11.420009202090004,1.968743909758197e-11,0.2534026654242676,314481.1085572418,-6.06463324081932,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,435.0,407.7,2.23,,,72.0,11.42,48.45,10.85,40.17,0.00287784,-0.1485477,42.8,1.7979643658339226,11.420010286286821,2.2628985473488034e-11,0.2515329219734709,279258.29074613884,-6.255967070016324,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-435-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,435.0,412.5,2.16,,,54.0,13.87,39.23,13.17,33.05,0.00467419,-0.08422681,43.1,1.3441831259365038,13.878294683807464,2.899290725120664e-12,0.14326684421522926,239.56442198325516,11.52552555555812,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-435-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,435.0,412.4,2.16,,,54.0,13.87,39.23,13.17,33.05,0.00625537,-0.08030380999999999,43.1,1.3582894725304788,13.877823906435404,3.927527862820451e-12,0.14080989239221742,249.62379429386698,19.811746667136923,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7609M-435-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,435.0,412.5,2.16,,,54.0,13.87,39.23,13.17,33.05,0.00599184,-0.0831676,43.1,1.357240190632282,13.877858501916409,3.840675830765134e-12,0.14099232749707555,248.84686755552133,15.46858630283954,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-435-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,435.0,408.9,2.1,,,60.0,13.32,41.21,12.53,34.78,0.0023842800000000003,-0.34097154,42.9,1.5292132123158682,13.331114706339681,2.5859163815948075e-11,0.13053679921678257,156.436897594684,-65.30788948774035,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-435-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,435.0,410.7,2.1,,,60.0,13.32,41.2,12.53,34.8,0.0114552,-0.117008,42.8,1.5820983421320132,13.32929258482047,6.415234894285825e-11,0.11853237785141706,169.9044261925186,8.017218990672582,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-435-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,435.0,409.1,2.1,,,60.0,13.32,41.21,12.53,34.78,0.0062337600000000005,-0.10871198,43.0,1.543130650567093,13.33066418710412,3.2987189332701936e-11,0.12804875892955062,159.93806776260394,10.78012752360662,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-440S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,440.0,412.3,2.2,,,72.0,11.48,48.6,10.92,40.37,0.0029388800000000005,-0.14147460000000003,42.9,1.7973924856233237,11.482875671142882,2.0663416989389245e-11,0.244607133439461,976.498990364713,-2.0014118557024796,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-440S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,440.0,412.2,2.23,,,72.0,11.48,48.6,10.92,40.37,0.0025370800000000006,-0.14711220000000003,42.8,1.7947940241179052,11.482930984763856,1.9868762119828215e-11,0.24513181829396738,960.1255458095361,-6.020202000392344,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-440S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,440.0,412.5,2.23,,,72.0,11.48,48.6,10.92,40.37,0.0028929600000000004,-0.14900760000000002,42.8,1.8067211459258021,11.480009430838892,2.3856486141513545e-11,0.24263617481262198,295359.6384329054,-5.895508031872015,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-440-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,440.0,413.7,2.1,,,60.0,13.38,41.46,12.6,34.99,0.00239502,-0.34304004000000005,42.9,1.537585438938196,13.390451312739785,2.5599395491127348e-11,0.13096868842937315,167.66899122907307,-65.350203919197,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-440-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,440.0,415.5,2.1,,,60.0,13.38,41.5,12.6,35.0,0.0115068,-0.11786,42.8,1.5914746266605702,13.388973613843087,6.230784073255585e-11,0.1238975428799156,184.7359573830568,7.717341820688039,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-440-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,440.0,413.9,2.1,,,60.0,13.38,41.46,12.6,34.99,0.00626184,-0.10937148,43.0,1.551642227776137,13.39001027668504,3.269612975673247e-11,0.12847034291215892,171.71685196791034,10.655566006494427,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-445S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,445.0,417.1,2.2,,,72.0,11.55,48.8,10.99,40.57,0.0029568000000000003,-0.1420568,42.9,1.8052841778914717,11.55265242570184,2.0950050691945222e-11,0.2406068794163993,1047.7223960263266,-1.9415248550218551,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-445S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,445.0,417.0,2.23,,,72.0,11.55,48.8,10.99,40.57,0.0025525500000000002,-0.1477176,42.8,1.8082120679613327,11.550008634897026,2.1970688582211258e-11,0.23993326708923962,320936.6392542325,-5.31601708873208,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-445S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,445.0,417.3,2.23,,,72.0,11.55,48.8,10.99,40.57,0.0029106,-0.1496208,42.8,1.8177884738896999,11.55000844921935,2.532739190602866e-11,0.23801995708051182,325374.3975549175,-5.486792651318512,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-445-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,445.0,418.5,2.1,,,60.0,13.45,41.69,12.67,35.18,0.00240755,-0.34494306,42.9,1.5457523333772274,13.460313415163924,2.5580874197653474e-11,0.1314239702924353,171.39350883758047,-65.36726498946673,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-445-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,445.0,420.3,2.1,,,60.0,13.45,41.7,12.67,35.2,0.011567,-0.118428,42.8,1.599631151350469,13.458648445901709,6.315150913024281e-11,0.12103968437989086,188.24003694695688,7.788589052436566,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-445-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,445.0,418.8,2.1,,,60.0,13.45,41.69,12.67,35.18,0.006294600000000001,-0.10997821999999999,43.0,1.5599090157515485,13.459872740355298,3.2688514621294545e-11,0.1289221550204203,175.63542897827924,10.605252832996237,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-450S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,450.0,421.9,2.2,,,72.0,11.6,49.05,11.06,40.76,0.0029695999999999998,-0.14278455,42.9,1.8123667390529623,11.60098238185193,2.0421255667947268e-11,0.2428074055646401,2867.0787403004615,-2.1866104247301146,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-450S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,450.0,421.8,2.23,,,72.0,11.6,49.05,11.06,40.76,0.0025636,-0.14847435,42.8,1.8164282159200695,11.600009461970682,2.17251019385127e-11,0.24196858100450142,296646.37626515643,-5.43474948035345,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-450S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,450.0,422.1,2.23,,,72.0,11.6,49.05,11.06,40.76,0.0029232,-0.1503873,42.8,1.8260439211605632,11.600014770982677,2.5044587384970002e-11,0.24006208187245395,188527.5465670122,-5.605159000372961,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-450-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,450.0,423.4,2.1,,,60.0,13.54,41.96,12.73,35.41,0.00242366,-0.34717704000000005,42.9,1.5574256569475033,13.551687278053738,2.6443645020548002e-11,0.13095151154536583,151.71055816034874,-65.29042248311869,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-450-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,450.0,425.2,2.1,,,60.0,13.54,42.0,12.73,35.4,0.0116444,-0.11927999999999998,42.8,1.611454130449463,13.550257070493222,6.376132342960964e-11,0.12565361147948484,165.8709394225597,7.821060652234787,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-450-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,450.0,423.6,2.1,,,60.0,13.54,41.96,12.73,35.41,0.00633672,-0.11069048,43.0,1.5715731005693947,13.551222696803734,3.3715398129713475e-11,0.12846193363027364,154.98722120382558,10.831460952952702,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,455.0,426.7,2.2,,,72.0,11.71,49.25,11.15,40.88,0.0029977600000000004,-0.14336675000000002,42.9,1.8198785349923503,11.712066513683938,2.0622361425952218e-11,0.24616896381355727,1394.9284246724656,-2.178478793318813,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,455.0,426.7,2.23,,,72.0,11.71,49.25,11.15,40.88,0.0025879100000000006,-0.14907975,42.8,1.8285847271557367,11.710008157864552,2.352479870291513e-11,0.24438949693889095,350806.53888615133,-4.89839337850768,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,455.0,426.9,2.23,,,72.0,11.71,49.25,11.15,40.88,0.00295092,-0.15100049999999998,42.8,1.8384135110615,11.710053768465722,2.7166550808671397e-11,0.24246057246424366,52793.109866786384,-5.056386444987624,-0.3625,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-455-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,455.0,428.2,2.1,,,60.0,13.62,42.23,12.79,35.64,0.0024379799999999997,-0.34941101999999996,42.9,1.5684950501658481,13.632546513843975,2.7045048131729537e-11,0.1306718790362986,141.8522327612418,-65.24226469369154,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-455-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,455.0,431.7,2.16,,,60.0,13.13,43.25,12.62,36.09,0.006000409999999999,-0.096015,43.2,1.466471462701455,13.130004783337888,2.040823699194328e-12,0.1989136186667888,546008.1168872274,4.996723034053469,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-455-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,455.0,428.4,2.1,,,60.0,13.62,42.23,12.79,35.64,0.006374159999999999,-0.11140273999999997,43.0,1.5826692400075117,13.632066640807697,3.443360170991568e-11,0.12818853433957395,144.69046344951647,10.97314579411194,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-460-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,460.0,433.0,2.1,,,60.0,13.74,42.49,12.85,35.86,0.0024594599999999997,-0.35156226000000007,42.9,1.5816452604827542,13.755423624478444,2.8816018514226378e-11,0.12973088056330173,115.56961260174585,-65.08303621543085,-0.3521,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,460.0,436.6,2.16,,,60.0,13.21,43.44,12.7,36.26,0.006036970000000001,-0.0964368,43.2,1.4717952277955177,13.210004805181768,2.007748832892396e-12,0.1977743462058974,543705.6473493825,4.800869913620501,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-460-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,460.0,433.2,2.1,,,60.0,13.74,42.49,12.85,35.86,0.00643032,-0.11208862,43.0,1.5956886510382409,13.754895460866905,3.651601516916436e-11,0.1272796709866336,117.40641692999685,11.440956307628383,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-465-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,465.0,437.8,2.1,,,60.0,13.82,42.7,12.91,36.03,0.00247378,-0.35329980000000005,42.9,1.590274245554124,13.836362324685012,2.934498371280796e-11,0.1301064224991287,109.89091099997405,-65.04657547390777,-0.3521,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-465-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,465.0,441.4,2.16,,,60.0,13.29,43.63,12.78,36.43,0.006073529999999999,-0.0968586,43.2,1.4771669767614661,13.290004826063006,1.9773530175177394e-12,0.19664088537731217,541510.2481485321,4.615089832674263,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-465-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,465.0,438.1,2.1,,,60.0,13.82,42.7,12.91,36.03,0.006467760000000001,-0.11264260000000001,43.0,1.604335552495132,13.835817291984473,3.714554441993088e-11,0.1276632068996179,111.54283099846806,11.547818611322256,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-475-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,475.0,451.1,2.16,,,60.0,13.45,44.01,12.94,36.77,0.00614665,-0.0977022,43.2,1.4880193307434173,13.450004865148605,1.922768009426853e-12,0.1943970888025082,537423.6250044754,4.267160488241931,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-480-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,480.0,456.0,2.16,,,60.0,13.53,44.2,13.01,36.94,0.00618321,-0.09812400000000002,43.2,1.4929481633169253,13.53000489848674,1.877750262229591e-12,0.19343933283215983,534295.4060925114,4.00985930590172,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-485-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,485.0,460.9,2.16,,,60.0,13.61,44.39,13.09,37.11,0.0062197699999999995,-0.0985458,43.2,1.5341929897284257,13.610144231141948,3.6982969405728495e-12,0.1861505452042213,17565.623203724102,9.977387014306032,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7610M-490-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,490.0,465.7,2.16,,,60.0,13.69,44.58,13.16,37.28,0.006256329999999999,-0.09896759999999999,43.2,1.5035795108423284,13.690004945149077,1.8192679046415812e-12,0.19136739763316576,529776.5897349312,3.633843359543647,-0.2969,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-520-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,520.0,487.8,2.595,,,72.0,13.32,49.39,12.55,41.51,0.0031435200000000003,-0.14579928,43.9,1.7887713389317317,13.33196729259483,1.334757065992595e-11,0.17946609990666781,199.75181849045848,-7.762441699501085,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-520-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,520.0,488.8,2.6,,,72.0,13.32,49.39,12.55,41.51,0.0043156800000000006,-0.11833844,43.0,1.8058556847566216,13.33147662454948,1.7339250538269064e-11,0.17640296240757142,204.73680732165303,16.036516588065066,-0.3455,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-520-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,520.0,488.7,2.6,,,72.0,13.32,49.39,12.55,41.51,0.00400932,-0.13261215,43.5,1.7908156368006403,13.33190800473691,1.3775674322333299e-11,0.17909899906155455,200.33571678123312,1.6101562771598854,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-525-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,525.0,492.6,2.595,,,72.0,13.37,49.52,12.6,41.74,0.0031553199999999997,-0.14618304000000001,43.9,1.854033859922222,13.37968245173624,3.305973332134253e-11,0.15796408644252016,218.12449042718117,-0.7888296561402384,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-525-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,525.0,493.6,2.6,,,72.0,13.37,49.52,12.6,41.74,0.004024369999999999,-0.13296120000000003,43.5,1.7979296850200683,13.381183547931965,1.4346103373028507e-11,0.1679596887511414,200.79683652934406,1.914308665220077,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-530-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,530.0,497.4,2.595,,,72.0,13.43,49.71,12.66,41.94,0.00316948,-0.14674392000000003,43.9,1.8034132311457303,13.4408958428119,1.410504883507167e-11,0.16464604528239965,202.93945435904962,-7.411405073261628,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-530-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,530.0,498.4,2.6,,,72.0,13.43,49.71,12.66,41.94,0.00435132,-0.11910516000000002,43.0,1.820558909493406,13.440432503121144,1.829352494761166e-11,0.16159060400423741,208.01925292746458,16.462925613156,-0.3455,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-530-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,530.0,498.4,2.6,,,72.0,13.43,49.71,12.66,41.94,0.00404243,-0.13347135000000002,43.5,1.8054457001367115,13.440840373023443,1.4550316820830821e-11,0.16428329109347672,203.52847709711656,1.993319964307921,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-535-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,535.0,502.2,2.595,,,72.0,13.48,49.8,12.71,42.17,0.00318128,-0.14700960000000002,43.9,1.867273513203338,13.488580906747723,3.46768317940816e-11,0.140312727476151,220.4214117913042,-0.47252335684407215,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-535-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,535.0,503.2,2.6,,,72.0,13.48,49.8,12.71,42.17,0.00436752,-0.1193208,43.0,1.8269417358435713,13.489572659498876,1.9227260733355825e-11,0.14744848806216748,207.63358679383438,16.898847393614826,-0.3455,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-535-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,535.0,503.2,2.6,,,72.0,13.48,49.8,12.71,42.17,0.00405748,-0.133713,43.5,1.811826331063883,13.489959466352794,1.5310747180148872e-11,0.1501377906276741,203.20942433660878,2.38509159038167,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-540-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,540.0,507.0,2.595,,,72.0,13.55,49.89,12.76,42.4,0.0031978,-0.14727528,43.9,1.8175549090487304,13.56000363034386,1.5942856386331063e-11,0.13602840721832832,184.25175503811383,-6.549081265869016,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,540.0,508.1,2.6,,,72.0,13.55,49.89,12.76,42.4,0.0043902,-0.11953644000000001,43.0,1.8346337200673246,13.559569583172205,2.0592824714219457e-11,0.1329924722149726,188.3099788593287,17.508992660602967,-0.3455,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-540-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,540.0,508.0,2.6,,,72.0,13.55,49.89,12.76,42.4,0.00407855,-0.13395465,43.5,1.8195255930472745,13.559952969392569,1.6424713109876536e-11,0.13567756193551328,184.71180781384336,2.9334800422479184,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-545-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,545.0,511.8,2.595,,,72.0,13.72,49.98,12.82,42.58,0.0032379200000000005,-0.14754096,43.9,1.8302732664117076,13.733721280557626,1.842494617612997e-11,0.12407602524037693,124.0644459282324,-5.510813285417805,-0.34,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-545-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,545.0,512.9,2.6,,,72.0,13.72,49.98,12.82,42.58,0.00444528,-0.11975208,43.0,1.8472151643799393,13.733198865855135,2.3678010770686323e-11,0.12106802114911237,125.84818064978649,18.76567555383288,-0.3455,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-545-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,545.0,512.8,2.6,,,72.0,13.72,49.98,12.82,42.58,0.00412972,-0.1341963,43.5,1.832148969937975,13.733662914269928,1.894812793155969e-11,0.12374249559950916,124.25951079374634,4.063097029182613,-0.3368,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-550-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,550.0,516.6,2.595,,,72.0,13.84,50.13,12.88,42.76,0.0032662399999999997,-0.14798376000000002,43.9,1.8407435929799796,13.855411869935697,1.991345157205712e-11,0.11799488319746879,105.96048329576556,-4.965261242876801,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-550-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,550.0,517.7,2.6,,,72.0,13.84,50.13,12.88,42.76,0.004484159999999999,-0.12011148000000002,43.0,1.8576418745323588,13.854841482768737,2.552119160747861e-11,0.11500322927533241,107.24297038328476,19.42517495975568,-0.3455,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM7612M-550-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,550.0,517.6,2.6,,,72.0,13.84,50.13,12.88,42.76,0.00416584,-0.13459905000000003,43.5,1.8425694796767216,13.855349713353558,2.045901282143634e-11,0.11767114582452111,106.09765953193967,4.6562285123416585,-0.3368,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-555-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,555.0,521.5,2.595,,,72.0,14.08,50.2,12.95,42.93,0.0033228800000000003,-0.1481904,43.9,1.857274409199388,14.099735075609768,2.45125091839485e-11,0.10407102921855448,74.24953025556307,-3.441298969105494,-0.34,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-555-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,555.0,522.5,2.6,,,72.0,14.08,50.2,12.95,42.93,0.00456192,-0.1202792,43.0,1.8739102683740325,14.0990216699766,3.11710645666867e-11,0.10112825432304735,74.85598400536807,21.264433738337548,-0.3455,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-555-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,555.0,522.5,2.6,,,72.0,14.08,50.2,12.95,42.93,0.00423808,-0.13478700000000002,43.5,1.8589341302092783,14.099663409697856,2.511213626984068e-11,0.10377700469854857,74.30960605631208,6.311423749271659,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-560-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,560.0,532.2,2.58,,,72.0,13.63,51.66,12.77,43.88,0.00603809,-0.1115856,43.0,1.8042541130806304,13.64572117972076,4.873155343774658e-12,0.15608386367737273,135.32210057682894,15.785930515917833,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-560-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,560.0,531.9,2.58,,,72.0,13.63,51.66,12.77,43.88,0.00609261,-0.11628665999999999,43.2,1.8097290695475972,13.645547411936315,5.314750301467798e-12,0.15509353106011442,135.96634853118024,11.86032980461602,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-560-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,560.0,531.9,2.58,,,72.0,13.63,51.66,12.77,43.88,0.004634200000000001,-0.10641959999999999,43.1,1.7846066513100722,13.64635365174156,3.554002789761502e-12,0.15964679054473654,133.05809555775127,18.479894941075212,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-565-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,565.0,537.0,2.58,,,72.0,13.7,51.85,12.84,44.03,0.006069099999999999,-0.11199600000000001,43.0,1.8103873183364945,13.715667924469438,4.861463047580131e-12,0.1569075982650496,137.19967196091136,15.712316222175831,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-565-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,565.0,536.7,2.58,,,72.0,13.7,51.85,12.84,44.03,0.006123899999999999,-0.11671435000000001,43.2,1.8158739898045935,13.715494483576089,5.301551305777431e-12,0.15592081902491556,137.86295018227366,11.7885313273428,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-565-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,565.0,536.7,2.58,,,72.0,13.7,51.85,12.84,44.03,0.004658,-0.106811,43.1,1.790679320151819,13.716299836686915,3.545521629864096e-12,0.16046107311450503,134.86740659163695,18.40448705819852,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-570-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,570.0,541.9,2.58,,,72.0,13.77,52.04,12.91,44.18,0.00610011,-0.11240639999999999,43.0,1.8165219505868007,13.785611501023102,4.850020259517098e-12,0.15772191569807933,139.11735824581575,15.639444654372692,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-570-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,570.0,541.6,2.58,,,72.0,13.77,52.04,12.91,44.18,0.006155189999999999,-0.11714203999999999,43.2,1.8220203650981972,13.785438379503383,5.2886308629183954e-12,0.15673864558590805,139.8003691281164,11.71745696296584,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-570-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,570.0,541.6,2.58,,,72.0,13.77,52.04,12.91,44.18,0.0046818,-0.10720239999999999,43.1,1.796753400406728,13.786242863874412,3.537223015657368e-12,0.1612660460411418,136.71440407018994,18.329842212073718,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-570-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,570.0,537.6,2.8,,,78.0,13.4,53.83,12.55,45.51,0.006432,-0.13861225,42.8,1.990269711324473,13.413937056304276,2.3451762840980172e-11,0.1639715447592676,157.65299782526643,10.369280308798968,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,570.0,535.2,2.8,,,78.0,13.4,53.83,12.55,45.51,0.0044354,-0.14216503,42.8,2.0184143566165873,13.41315824622806,3.4216191545902896e-11,0.15892895830756185,161.84892881805013,11.129325066083084,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-570-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,570.0,536.2,2.8,,,78.0,13.4,53.83,12.55,45.51,0.0051188,-0.14011948999999999,42.9,1.9994721273058287,13.413679670775968,2.6565869253155998e-11,0.1623198877392361,159.0013780068026,10.413071213238526,-0.3457,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-575-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,575.0,546.8,2.58,,,72.0,13.84,52.23,12.97,44.34,0.0061311199999999995,-0.1128168,43.0,1.823491318798035,13.855993752713394,4.898091184549567e-12,0.1575572739064128,136.34027682910366,15.687320358422008,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-575-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,575.0,546.4,2.58,,,72.0,13.84,52.23,12.97,44.34,0.006186479999999999,-0.11756973,43.2,1.8290152462397262,13.855817707192601,5.3413317441528194e-12,0.15657392864200242,136.99729977063822,11.764123448792864,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-575-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,575.0,546.4,2.58,,,72.0,13.84,52.23,12.97,44.34,0.0047056,-0.10759379999999999,43.1,1.8036433090073896,13.856635308577486,3.5722848300867094e-12,0.1610994864690951,134.02918662485575,18.37902393689218,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-575-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,575.0,542.4,2.8,,,78.0,13.48,53.9,12.62,45.65,0.0064704,-0.1387925,42.8,1.9950262665211351,13.493688442470038,2.428056665462309e-11,0.15580593859210679,153.4333846583412,10.629784009968084,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-575-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,575.0,540.0,2.8,,,78.0,13.48,53.9,12.62,45.65,0.00446188,-0.1423499,42.8,2.0232771315766582,13.492911282648457,3.542899762058035e-11,0.15076563602224008,157.40657551758352,11.39117975550036,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-575-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,575.0,541.0,2.8,,,78.0,13.48,53.9,12.62,45.65,0.0051493599999999995,-0.1403017,42.9,2.004266661851238,13.493431486058848,2.750689043776088e-11,0.15415444817367713,154.71124770729372,10.673685139915383,-0.3457,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-580-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,580.0,551.6,2.58,,,72.0,13.91,52.42,13.04,44.5,0.00616213,-0.1132272,43.0,1.8298173098278978,13.92585634971403,4.901179434946515e-12,0.15748944926966024,138.15779037886736,15.643510351076825,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-580-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,580.0,551.3,2.58,,,72.0,13.91,52.42,13.04,44.5,0.006217769999999999,-0.11799741999999999,43.2,1.835356300689901,13.92568093244159,5.344436451770397e-12,0.15650881526042654,138.83342907479886,11.721410254020585,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-580-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,580.0,551.3,2.58,,,72.0,13.91,52.42,13.04,44.5,0.004729400000000001,-0.10798519999999999,43.1,1.8099038981915625,13.926496001589445,3.5745439751118234e-12,0.1610238947389254,135.78092645548895,18.334058011830503,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-580-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,580.0,547.2,2.8,,,78.0,13.56,53.98,12.69,45.8,0.0065088,-0.1389985,42.8,2.000184738532809,13.573391973840526,2.5145002886196875e-11,0.14762261149660516,149.47480076949964,10.893429127063584,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-580-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,580.0,544.9,2.8,,,78.0,13.56,53.98,12.69,45.8,0.004488359999999999,-0.14256117999999998,42.8,2.028548883851544,13.572616679957553,3.669442586923154e-11,0.1425831905547301,153.24380734035435,11.65628469576586,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-580-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,580.0,545.8,2.8,,,78.0,13.56,53.98,12.69,45.8,0.005179919999999999,-0.14050993999999997,42.9,2.009465717349123,13.573135510959945,2.8488631840166244e-11,0.1459707804057051,150.6879934602714,10.937501194374356,-0.3457,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-585-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,585.0,556.5,2.58,,,72.0,13.98,52.61,13.1,44.66,0.006193140000000001,-0.1136376,43.0,1.8367856129963287,13.996239112173296,4.949251900744366e-12,0.15732786095413245,135.44111735986573,15.69087399909386,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,585.0,556.1,2.58,,,72.0,13.98,52.61,13.1,44.66,0.00624906,-0.11842511,43.2,1.842350136060021,13.996060785454391,5.397142007135884e-12,0.1563471378264668,136.09128839632768,11.767582655802848,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-585-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,585.0,556.2,2.58,,,72.0,13.98,52.61,13.1,44.66,0.004753200000000001,-0.10837659999999999,43.1,1.8167927763132432,13.996888964910525,3.609607610212134e-12,0.16086044505294173,133.15375076516352,18.382715140076584,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-585-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,585.0,552.1,2.8,,,78.0,13.64,54.07,12.75,45.97,0.006547200000000001,-0.13923025000000003,42.8,2.006752215952947,13.653398202324528,2.6376170664201723e-11,0.13837524572229232,140.87250764824353,11.277216747853736,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,585.0,549.7,2.8,,,78.0,13.64,54.07,12.75,45.97,0.00451484,-0.14279887000000002,42.8,2.0352725099388445,13.652610168640056,3.849922537342571e-11,0.1333233400353701,144.21142317806033,12.042756848366677,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-585-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,585.0,550.7,2.8,,,78.0,13.64,54.07,12.75,45.97,0.005210480000000001,-0.14074421,42.9,2.0160906251107154,13.653137358712948,2.988820151574641e-11,0.1367181956798792,141.94909618314026,11.32190721516591,-0.3457,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-590-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,590.0,561.3,2.58,,,72.0,14.05,52.8,13.17,44.82,0.00622415,-0.11404800000000001,43.0,1.8431122103773492,14.06610149243507,4.952317346020509e-12,0.15726172351146409,137.22499494750028,15.647452446958095,-0.2953,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-590-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,590.0,561.0,2.58,,,72.0,14.05,52.8,13.17,44.82,0.0062803500000000005,-0.11885280000000001,43.2,1.8486918009523972,14.065923791990574,5.400221025070143e-12,0.15628367017932165,137.89338433578882,11.72524696351866,-0.2954,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7612M-590-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,590.0,561.0,2.58,,,72.0,13.63,51.66,12.77,43.88,0.004634200000000001,-0.10641959999999999,43.1,1.7846066513100722,13.64635365174156,3.554002789761502e-12,0.15964679054473654,133.05809555775127,18.479894941075212,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-590-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,590.0,556.9,2.8,,,78.0,13.72,54.15,12.82,46.11,0.006585600000000001,-0.13943625,42.8,2.011686368976015,13.733083622326426,2.7222689629206548e-11,0.1312669842548295,137.6517133019786,11.512075171264955,-0.3335,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-590-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,590.0,554.5,2.8,,,78.0,13.72,54.15,12.82,46.11,0.004541320000000001,-0.14301015,42.8,2.040314554573258,13.732295537873133,3.973961906572396e-11,0.1262177099373348,140.84027926839778,12.279137805274214,-0.3577,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-590-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,590.0,555.5,2.8,,,78.0,13.72,54.15,12.82,46.11,0.005241040000000001,-0.14095244999999998,42.9,2.021063804730019,13.732822633446817,3.085023019484296e-11,0.12961014295096604,138.68065197738946,11.557059126505683,-0.3457,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-595-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,595.0,561.7,2.8,,,78.0,13.81,54.24,12.88,46.29,0.0066288,-0.13966800000000001,42.8,2.019213647095649,13.823197373393802,2.8903516638037635e-11,0.1210615982700996,126.68131960339902,12.005072348115881,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-595-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,595.0,559.3,2.8,,,78.0,13.81,54.24,12.88,46.29,0.00457111,-0.14324784,42.8,2.048035680271175,13.822381576449477,4.220740838595054e-11,0.11599171542750482,129.37331551143498,12.77626793323323,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-595-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,595.0,560.3,2.8,,,78.0,13.81,54.24,12.88,46.29,0.005275419999999999,-0.14118672,42.9,2.0286643744997512,13.822926987457071,3.2763011273460144e-11,0.11939626551288483,127.55194797741581,12.05130060401563,-0.3457,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,595.0,566.8,2.52,,,66.0,15.69,47.65,14.68,40.54,0.005852370000000001,-0.1047347,43.0,1.6490507726966415,15.709105392198442,4.302747336724794e-12,0.1225732461283219,100.66133229489162,11.421216834583554,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-595R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,595.0,567.0,2.52,,,66.0,15.69,47.65,14.68,40.54,0.00655842,-0.0969201,42.9,1.6507115949297182,15.709037042782635,4.429852434115679e-12,0.12231043237173905,100.80613395683544,20.690292114196883,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-600-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,600.0,566.6,2.8,,,78.0,14.08,54.31,12.95,46.42,0.0067584,-0.13984825,42.8,2.0379497870203025,14.098957191382162,3.584944974058117e-11,0.10963368133001809,81.42779198220687,13.861954034543087,-0.3335,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-600-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,600.0,564.1,2.8,,,78.0,14.08,54.31,12.95,46.42,0.00466048,-0.14343271000000002,42.8,2.0674261079118015,14.097818623788719,5.2450188993134456e-11,0.10445406220423684,82.53797923688622,14.656111692153125,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-600-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,600.0,565.1,2.8,,,78.0,14.08,54.31,12.95,46.42,0.00537856,-0.14136893,42.9,2.047668358952461,14.098578573493029,4.069081773165623e-11,0.1079229016568692,81.7906961242713,13.91774223228217,-0.3457,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-600R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,600.0,571.7,2.52,,,66.0,15.74,47.85,14.73,40.74,0.00587102,-0.10517430000000001,43.0,1.6563699274809598,15.758674268586763,4.347347996494317e-12,0.1204228060691773,101.5008946491297,11.485953670378525,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-600R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,600.0,571.8,2.52,,,66.0,15.74,47.85,14.73,40.74,0.00657932,-0.09732690000000001,42.9,1.658028457390753,15.758606931375342,4.474984973930361e-12,0.12016113667926845,101.64686772642256,20.758700702883413,-0.2925,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM7613M-605-H-HC,Boviet Solar Technology Co Ltd,Mono-c-Si,0,605.0,571.4,2.8,,,78.0,14.16,54.4,13.02,46.56,0.0067968,-0.14008,42.8,2.0430517139307267,14.178220865833095,3.685708370354814e-11,0.10356656443795151,80.48478981715472,14.06731470043158,-0.3335,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-605-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,605.0,568.9,2.8,,,78.0,14.16,54.4,13.02,46.56,0.0046869599999999996,-0.1436704,42.8,2.072640330513488,14.17707973798855,5.393334806205419e-11,0.09838995901443769,81.57044474561542,14.863452406996057,-0.3577,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM7613M-605-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,605.0,570.0,2.8,,,78.0,14.16,54.4,13.02,46.56,0.00540912,-0.14160319999999998,42.9,2.052812161752421,14.177841192449742,4.183952363725387e-11,0.10185592879674042,80.83988551676642,14.123773947933271,-0.3457,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-605R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,605.0,576.6,2.52,,,66.0,15.79,48.05,14.78,40.94,0.00588967,-0.1056139,43.0,1.6636882423897343,15.808249259115541,4.392030204087016e-12,0.1182873472553159,102.34701600881263,11.550020466453873,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-605R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,605.0,576.7,2.52,,,66.0,15.79,48.05,14.78,40.94,0.006600219999999999,-0.09773369999999999,42.9,1.6653444146746395,15.808182919813849,4.520188705516624e-12,0.11802680275560243,102.49416680856692,20.826456561653846,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,610.0,581.5,2.52,,,66.0,15.84,48.25,14.83,41.14,0.005908320000000001,-0.1060535,43.0,1.6710057281926298,15.8578302792885,4.4367925944093104e-12,0.11616671232543853,103.19977014282081,11.613427217661608,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-610R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,610.0,581.6,2.52,,,66.0,15.84,48.25,14.83,41.14,0.00662112,-0.09814049999999999,42.9,1.6726595709332315,15.857764924874015,4.565468239024665e-12,0.11590729408517898,103.34811727451098,20.8934812086398,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-615R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,615.0,586.4,2.52,,,66.0,15.89,48.45,14.88,41.34,0.00592697,-0.10649310000000001,43.0,1.6783223934918148,15.90741724621745,4.481633672217578e-12,0.11406074644456994,104.0592318260075,11.676183427609313,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-615R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,615.0,586.5,2.52,,,66.0,15.89,48.45,14.88,41.34,0.00664202,-0.0985473,42.9,1.6799739046228306,15.90735286351306,4.610820205200671e-12,0.1138024487965399,104.20879014817379,20.959814582660485,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-620R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,620.0,591.2,2.52,,,66.0,15.94,48.65,14.93,41.54,0.0059456199999999996,-0.10693269999999999,43.0,1.6856382480848155,15.957010078380188,4.526552069380697e-12,0.11196929674633642,104.9254771871568,11.73829862215545,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-620R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,620.0,591.3,2.52,,,66.0,15.94,48.65,14.93,41.54,0.006662919999999999,-0.0989541,42.9,1.6872874252073276,15.956946654454836,4.656243245356653e-12,0.11171211404535068,105.07626172114234,21.02546696503594,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-625R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,625.0,596.1,2.52,,,66.0,15.99,48.85,14.98,41.73,0.005964270000000001,-0.1073723,43.0,1.6927647660980705,16.006715635879125,4.556969054677957e-12,0.11064853118836626,105.8452114766512,11.77025212939624,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-625R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,625.0,596.2,2.52,,,66.0,15.99,48.85,14.98,41.73,0.00668382,-0.0993609,42.9,1.6944159828602066,16.006652832301267,4.6871223489182764e-12,0.11039182040708376,105.99789742352958,21.05923969830876,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-630R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,630.0,601.0,2.52,,,66.0,16.07,49.05,15.03,41.92,0.00599411,-0.1078119,43.0,1.7013660780699225,16.08768231558734,4.702110441154766e-12,0.10890544160109365,98.97518438833048,12.022085134771437,-0.2919,N,2025.7.3,6/23/2025,4.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-630R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,630.0,601.1,2.52,,,66.0,16.07,49.05,15.03,41.92,0.00671726,-0.0997677,42.9,1.7029864258258962,16.08761834303874,4.833060356167364e-12,0.10865418535016644,99.10539008078375,21.32533098746129,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-635R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,635.0,605.9,2.52,,,66.0,16.12,49.25,15.09,42.12,0.006012760000000001,-0.1082515,43.0,1.7081553999971897,16.1368373959357,4.709538480632232e-12,0.10693474203323161,102.37854172938934,12.003765418573416,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-635R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,635.0,606.0,2.52,,,66.0,16.12,49.25,15.09,42.12,0.00673816,-0.1001745,42.9,1.7097851635503465,16.13677496418787,4.840947527908425e-12,0.10668296412818541,102.517618709846,21.30599716518076,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-640R-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,640.0,610.8,2.52,,,66.0,16.17,49.45,15.14,42.31,0.00603141,-0.10869110000000001,43.0,1.715281436648956,16.186544309842976,4.740200820705187e-12,0.10564492348234687,103.25474013499117,12.034185967215393,-0.2919,N,2025.7.3,6/23/2025,2.0,first_pass +Boviet Solar Technology Co Ltd BVM8611M-640R-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,640.0,610.9,2.52,,,66.0,16.17,49.45,15.14,42.31,0.00675906,-0.10058130000000001,42.9,1.7169132370424378,16.186482478912865,4.872060404525289e-12,0.10539360909008828,103.39553102824134,21.338115507108576,-0.2925,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-685-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,685.0,652.3,2.91,,,66.0,18.19,48.08,17.21,39.84,0.00802179,-0.1067376,43.0,1.6533185767191447,18.20740312163376,4.209930995330699e-12,0.17552569418269773,183.4620505849897,8.606549076885065,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-685-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,685.0,652.7,2.91,,,66.0,18.19,48.08,17.21,39.84,0.008149120000000001,-0.10933392,42.9,1.6515676740893421,18.20748710125995,4.081929147312145e-12,0.17575613019164582,182.82069537914097,5.728990401657259,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-690-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,690.0,657.1,2.91,,,66.0,18.24,48.25,17.26,40.02,0.008043839999999998,-0.107115,43.0,1.659800803441924,18.2570628428445,4.269228462647385e-12,0.17308562916793954,185.02672150762345,8.7072988110234,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-690-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,690.0,657.6,2.91,,,66.0,18.24,48.25,17.26,40.02,0.00817152,-0.1097205,42.9,1.6580472504174826,18.257145643837898,4.139779583609413e-12,0.17331590383601916,184.37814993279932,5.827877348487525,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-695-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,695.0,662.0,2.91,,,66.0,18.29,48.42,17.31,40.19,0.008065890000000001,-0.1074924,43.0,1.6660908076533547,18.306766562701867,4.3145643119228406e-12,0.17131702922018383,186.8831748358113,8.77729053734949,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-695-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,695.0,662.5,2.91,,,66.0,18.29,48.42,17.31,40.19,0.00819392,-0.11010708,42.9,1.6643335034107039,18.30684848985578,4.1839878332844976e-12,0.17154722241167933,186.2243280590458,5.896650403341067,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-700-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,700.0,666.9,2.91,,,66.0,18.34,48.59,17.36,40.36,0.00808794,-0.10786980000000002,43.0,1.6723801345355578,18.356473972141274,4.360044087431547e-12,0.16955891614457722,188.76507134307369,8.846750381075342,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-700-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,700.0,667.4,2.91,,,66.0,18.34,48.59,17.36,40.36,0.008216320000000001,-0.11049366000000001,42.9,1.6706193044242845,18.35655502143974,4.228352816791802e-12,0.16978907012922012,188.09589354646585,5.964677198171847,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-705-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,705.0,671.8,2.91,,,66.0,18.39,48.76,17.41,40.53,0.008109990000000001,-0.1082472,43.0,1.6786689114227087,18.406185031521897,4.40567390329257e-12,0.16781122256441863,190.67299209283797,8.91556840725608,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-705-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,705.0,672.2,2.91,,,66.0,18.39,48.76,17.41,40.53,0.00823872,-0.11088023999999999,42.9,1.6769044054347413,18.406265217406713,4.272857176788737e-12,0.16804131018141433,189.99313818920376,6.032218083941363,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-710-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,710.0,676.6,2.91,,,66.0,18.44,48.93,17.46,40.7,0.00813204,-0.1086246,43.0,1.6849571550350932,18.455899705212737,4.451453185515313e-12,0.16607385676161654,192.60746548100914,8.98374178517675,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-710-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,710.0,677.1,2.91,,,66.0,18.44,48.93,17.46,40.7,0.00826112,-0.11126682,42.9,1.6831887952665467,18.45597904176454,4.31749861507525e-12,0.1663038425578051,191.91656834969993,6.09929288086104,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-715-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,715.0,681.5,2.91,,,66.0,18.49,49.1,17.51,40.87,0.00815409,-0.10900200000000002,43.0,1.6912446422030094,18.505617966893038,4.497366009353137e-12,0.16434668151108028,194.56886842902193,9.051498713413494,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-715-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,715.0,682.0,2.91,,,66.0,18.49,49.1,17.51,40.87,0.008283519999999999,-0.1116534,42.9,1.6894727530427631,18.505696449046603,4.362292657851759e-12,0.16457663243266787,193.8669012845664,6.1656483249843985,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-720-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,720.0,686.4,2.91,,,66.0,18.54,49.27,17.56,41.04,0.008176139999999998,-0.1093794,43.0,1.697531607781682,18.5553397737532,4.543425621196986e-12,0.16262965111388286,196.55790134477098,9.118625071187292,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-720-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,720.0,686.9,2.91,,,66.0,18.54,49.27,17.56,41.04,0.00830592,-0.11203998,42.9,1.6957559385478687,18.555417417770936,4.407216599195419e-12,0.16285951644826765,195.84443283968074,6.231619446177013,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-725-H-HC-BF,Boviet Solar Technology Co Ltd,Mono-c-Si,1,725.0,691.3,2.91,,,66.0,18.59,49.44,17.61,41.21,0.008198190000000001,-0.1097568,43.0,1.703817981457991,18.605065094448587,4.589625852107948e-12,0.16092266087185353,198.57507566110456,9.185201020588027,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +Boviet Solar Technology Co Ltd BVM8611M-725-H-HC-BF-DG,Boviet Solar Technology Co Ltd,Mono-c-Si,1,725.0,691.8,2.91,,,66.0,18.59,49.44,17.61,41.21,0.00832832,-0.11242656,42.9,1.702038615053312,18.60514190407526,4.4522851038934485e-12,0.16115245880190787,197.84990041388164,6.296969285552566,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi,Bright Spot Solar LLC,Mono-c-Si,1,445.0,416.2,2.21,,,72.0,11.37,50.6,10.61,42.0,0.005002799999999999,-0.14926999999999999,43.8,1.9149218099039778,11.387552144281491,3.704097210525106e-11,0.25322636073360627,164.03601155311625,1.269640433926775,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 225P6C-30,BYD Company Limited,Multi-c-Si,0,225.0,202.7,1.6268799999999999,1.64,0.992,60.0,8.41,36.21,7.85,28.66,0.00443207,-0.07712730000000001,47.5,1.3967622682275007,8.427017418648914,4.551476235208506e-11,0.4350571755129313,215.00504684068738,46.32199331358151,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 230P6C-30,BYD Company Limited,Multi-c-Si,0,230.0,207.3,1.6268799999999999,1.64,0.992,60.0,8.49,36.52,7.94,28.97,0.00447423,-0.0777876,47.5,1.4090582295927558,8.504905182846311,4.632785575905357e-11,0.42492371860420586,242.03678278173737,46.41012332848652,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 235P6C-30,BYD Company Limited,Multi-c-Si,0,235.0,212.0,1.6268799999999999,1.64,0.992,60.0,8.57,36.83,8.03,29.27,0.0045163899999999995,-0.0784479,47.5,1.4211143390342065,8.582899478757707,4.694049707262051e-11,0.41647329154614054,276.69151001839464,46.44512823210172,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 240P6C-30,BYD Company Limited,Multi-c-Si,0,240.0,216.6,1.6268799999999999,1.64,0.992,60.0,8.65,37.14,8.12,29.57,0.00455855,-0.0791082,47.5,1.4331710872617687,8.660972610563116,4.755427819551253e-11,0.4082126710452149,321.8048931400337,46.47955614239519,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 245P6C-30,BYD Company Limited,Multi-c-Si,0,245.0,221.2,1.6268799999999999,1.64,0.992,60.0,8.73,37.45,8.21,29.85,0.00460071,-0.0797685,47.5,1.444755821441576,8.739120577938442,4.776643006884441e-11,0.4029707384284977,385.7140146655611,46.41358663114201,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD245P6K-30,BYD Company Limited,Multi-c-Si,0,245.0,224.4,1.63,,,60.0,8.73,37.45,8.21,29.85,0.00336978,-0.11665675000000002,45.1,1.4396243091957297,8.7393248462954,4.3542446925607825e-11,0.4042802761910285,378.49063396226666,-0.7574667078792872,-0.3983,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 250P6C-30,BYD Company Limited,Multi-c-Si,0,250.0,225.8,1.6268799999999999,1.64,0.992,60.0,8.81,37.76,8.3,30.13,0.00464287,-0.0804288,47.5,1.4563448993806862,8.817317198497433,4.7982392141842776e-11,0.397841503853099,479.0062592797923,46.34949954860662,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD250P6K-30,BYD Company Limited,Multi-c-Si,0,250.0,229.1,1.63,,,60.0,8.81,37.76,8.3,30.13,0.0034006600000000007,-0.1176224,45.1,1.4511451377581654,8.817516314933602,4.371698217150147e-11,0.3991547272935173,467.856042334735,-0.8045843912355917,-0.3983,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 255P6C-30,BYD Company Limited,Multi-c-Si,0,255.0,230.5,1.6268799999999999,1.64,0.992,60.0,8.89,38.07,8.39,30.4,0.00468503,-0.08108910000000001,47.5,1.4677035514736876,8.895547108754492,4.8004477027959643e-11,0.3942072786070857,631.7710992594369,46.2384453010153,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD255P6K-30,BYD Company Limited,Multi-c-Si,0,255.0,233.7,1.63,,,60.0,8.89,38.07,8.39,30.4,0.0034315400000000003,-0.11858805000000001,45.1,1.4624116466384716,8.895742622139664,4.369519837099419e-11,0.39552973279645176,612.3090649953658,-0.8869790815283324,-0.3983,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 260P6C-30,BYD Company Limited,Multi-c-Si,0,260.0,235.1,1.6268799999999999,1.64,0.992,60.0,8.97,38.38,8.48,30.67,0.00472719,-0.0817494,47.5,1.4790679000266242,8.973809914961668,4.8033350161772407e-11,0.39064803831099587,919.735314423843,46.13023380762356,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 260P6C-36,BYD Company Limited,Multi-c-Si,0,260.0,236.2,1.9403519999999999,1.956,0.992,72.0,8.24,42.81,7.62,34.12,0.00378216,-0.13185480000000002,45.6,1.6947867736134767,8.264195777615557,8.571630681651848e-11,0.48157243222913904,164.0020420570511,6.458877111184763,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD260P6K-30,BYD Company Limited,Multi-c-Si,0,260.0,238.4,1.63,,,60.0,8.97,38.38,8.48,30.67,0.0034624200000000003,-0.11955370000000001,45.1,1.4736844170853793,8.974001706032722,4.368066798130694e-11,0.39197938762922413,878.6391244209124,-0.9672449989160085,-0.3983,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 265P6C-30,BYD Company Limited,Multi-c-Si,0,265.0,239.8,1.6268799999999999,1.64,0.992,60.0,9.05,38.69,8.57,30.93,0.00476935,-0.08240969999999999,47.5,1.4902046516771215,9.052077859053552,4.7875766170933435e-11,0.3885171807021568,1692.1654356725492,45.97710154685605,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 265P6C-36,BYD Company Limited,Multi-c-Si,0,265.0,240.8,1.9403519999999999,1.956,0.992,72.0,8.31,43.11,7.71,34.37,0.0038142900000000006,-0.1327788,45.6,1.7041108735167816,8.331110247389026,8.355822792654015e-11,0.4790380471086815,188.57222490656963,6.156292637313692,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD265P6K-30,BYD Company Limited,Multi-c-Si,0,265.0,243.1,1.63,,,60.0,9.05,38.69,8.57,30.92,0.003493300000000001,-0.12051934999999998,45.1,1.4844492807064094,9.052241872107517,4.328411604087281e-11,0.39122384444816544,1579.2945783591913,-1.1169730412435492,-0.3983,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 270P6C-36,BYD Company Limited,Multi-c-Si,0,270.0,245.5,1.9403519999999999,1.956,0.992,72.0,8.38,43.41,7.8,34.62,0.003846420000000001,-0.13370279999999998,45.6,1.7134758207381258,8.398053394860623,8.152474174423078e-11,0.4765420478561409,221.20064017817393,5.862636196497815,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD270P6K-30,BYD Company Limited,Multi-c-Si,0,270.0,247.8,1.63,,,60.0,9.13,39.0,8.66,31.18,0.0035241800000000005,-0.12148500000000001,45.1,1.4954796186383386,9.130519191909649,4.309595580472059e-11,0.38913317103071676,6842.919132843329,-1.2277634369383899,-0.3983,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 275P6C-36,BYD Company Limited,Multi-c-Si,0,275.0,250.1,1.9403519999999999,1.956,0.992,72.0,8.45,43.7,7.89,34.85,0.0038785499999999997,-0.13459600000000002,45.6,1.7221565163738746,8.465052461113117,7.922464085173772e-11,0.47576448146374384,267.07991706017754,5.536509270813081,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD275P6K-30,BYD Company Limited,Multi-c-Si,0,275.0,252.6,1.63,,,60.0,9.21,39.31,8.75,31.43,0.003555060000000001,-0.12245065000000001,45.1,1.5078273940648672,9.21000353833999,4.384601238017202e-11,0.3841392194123723,999999.8306246231,-1.1616978216559926,-0.3983,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD 280P6C-36,BYD Company Limited,Multi-c-Si,0,280.0,254.8,1.9403519999999999,1.956,0.992,72.0,8.52,44.0,7.98,35.09,0.003910680000000001,-0.13552,45.6,1.7313284561026265,8.53205061600038,7.711966424722433e-11,0.47479368285747664,335.68760462389884,5.226435299259971,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD280P6K-30,BYD Company Limited,Multi-c-Si,0,280.0,257.3,1.63,,,60.0,9.29,39.62,8.84,31.68,0.00358594,-0.12341629999999999,45.1,1.5208313675853538,9.290003505873791,4.507894378875988e-11,0.3773375789821529,999999.8375710391,-1.0096942980877246,-0.3983,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD 285P6C-36,BYD Company Limited,Multi-c-Si,0,285.0,259.4,1.9403519999999999,1.956,0.992,72.0,8.6,44.3,8.07,35.4,0.0039474,-0.136444,45.6,1.743436293384982,8.610209679197865,7.834370980333159e-11,0.4631816991136052,390.1555382679225,5.274494116395528,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 290P6C-36,BYD Company Limited,Multi-c-Si,0,290.0,264.1,1.9403519999999999,1.956,0.992,72.0,8.67,44.6,8.16,35.65,0.00397953,-0.137368,45.6,1.7529326323108236,8.67729437682535,7.664829703776155e-11,0.4609098292540082,547.8313892287779,5.009445023690473,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 295P6C-36,BYD Company Limited,Multi-c-Si,0,295.0,268.8,1.9403519999999999,1.956,0.992,72.0,8.75,44.9,8.25,35.76,0.004016250000000001,-0.138292,45.6,1.7596919406321772,8.755415036529177,7.21107708077488e-11,0.4780957692862638,772.54113160245,4.409203537209044,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD295P6K-36,BYD Company Limited,Multi-c-Si,0,295.0,270.0,1.94,,,72.0,8.75,44.9,8.25,35.76,0.00350875,-0.1353735,46.1,1.6945566574844535,8.757512297113939,2.6987877144853566e-11,0.49461496589625953,576.1059540430375,-1.372084239579544,-0.3827,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 300P6C-36,BYD Company Limited,Multi-c-Si,0,300.0,273.4,1.9403519999999999,1.956,0.992,72.0,8.83,45.19,8.34,35.97,0.00405297,-0.13918519999999998,45.6,1.7689899652983518,8.833556470947148,7.078327206548338e-11,0.4796238718340739,1190.8095671201854,4.169847111841915,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD300P6K-36,BYD Company Limited,Multi-c-Si,0,300.0,274.7,1.94,,,72.0,8.83,45.19,8.34,35.97,0.00354083,-0.13624784999999998,46.1,1.7035660823009677,8.835623149110793,2.6483364858604534e-11,0.49602339671941104,778.9028453447697,-1.6013138181609035,-0.3827,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 305P6C-36,BYD Company Limited,Multi-c-Si,0,305.0,278.1,1.9403519999999999,1.956,0.992,72.0,8.91,45.49,8.43,36.18,0.00408969,-0.14010920000000002,45.6,1.7784883823545128,8.911652990079368,6.930481457078018e-11,0.4823203698146013,2599.819257637089,3.910592581998297,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD305P6K-36,BYD Company Limited,Multi-c-Si,0,305.0,279.4,1.94,,,72.0,8.91,45.49,8.43,36.18,0.0035729099999999995,-0.13715235,46.1,1.7127738374453974,8.913694386123272,2.592221276438404e-11,0.498600521041865,1202.5085132984448,-1.8495385790323573,-0.3827,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 310P6C-36,BYD Company Limited,Multi-c-Si,0,310.0,282.8,1.9403519999999999,1.956,0.992,72.0,8.99,45.79,8.52,36.38,0.0041264100000000005,-0.1410332,45.6,1.7882176252241584,8.990004417815321,6.807610703556863e-11,0.4862231170868937,989596.4675753106,3.680619875352754,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD310P6K-36,BYD Company Limited,Multi-c-Si,0,310.0,284.1,1.94,,,72.0,8.99,45.79,8.52,36.38,0.00360499,-0.13805684999999998,46.1,1.721752999788067,8.991705395771302,2.5290060978289272e-11,0.5024805051680309,2648.8282922764274,-2.1223962391917377,-0.3827,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD 315P6C-36,BYD Company Limited,Multi-c-Si,0,315.0,287.4,1.9403519999999999,1.956,0.992,72.0,9.07,46.09,8.61,36.59,0.00416313,-0.1419572,45.6,1.800636937339695,9.070004352694752,6.937250781601715e-11,0.47982171809893925,999999.8479899092,3.7642037311374272,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD315P6K-36,BYD Company Limited,Multi-c-Si,0,315.0,288.8,1.94,,,72.0,9.07,46.09,8.61,36.58,0.0036370699999999996,-0.13896135,46.1,1.731193689925212,9.070004580962472,2.4847078815160396e-11,0.5050308148373104,999999.6540901545,-2.337407977495484,-0.3827,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD320P6K-36,BYD Company Limited,Multi-c-Si,0,320.0,293.5,1.94,,,72.0,9.15,46.39,8.7,36.78,0.0036691500000000004,-0.13986585,46.1,1.7429028941946512,9.150004585619378,2.52356080650805e-11,0.5011249380415974,999999.8383847473,-2.284283390266795,-0.3827,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD325P6K-36,BYD Company Limited,Multi-c-Si,0,325.0,298.2,1.94,,,72.0,9.23,46.69,8.79,36.98,0.00370123,-0.14077035,46.1,1.7546040872556194,9.230004588897467,2.5622836799976636e-11,0.4971365008650351,999999.3763983538,-2.232800526033251,-0.3827,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD330P6K-36,BYD Company Limited,Multi-c-Si,0,330.0,302.9,1.94,,,72.0,9.31,46.98,8.88,37.16,0.0037333099999999997,-0.14164469999999998,46.1,1.7656716813219842,9.31000460323854,2.5910998629035586e-11,0.4944044413984051,999998.3045916965,-2.2126397585124242,-0.3827,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD335P6K-36,BYD Company Limited,Multi-c-Si,0,335.0,307.6,1.94,,,72.0,9.39,47.28,8.97,37.35,0.00376539,-0.1425492,46.1,1.7771498073487937,9.390004614750998,2.6213231556184085e-11,0.49141440799901703,999990.4184270679,-2.188628127415776,-0.3827,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD340P6K-36,BYD Company Limited,Multi-c-Si,0,340.0,312.3,1.94,,,72.0,9.47,47.58,9.06,37.53,0.00379747,-0.1434537,46.1,1.788412966097433,9.470004947110155,2.6431372781024736e-11,0.4894819416223652,937051.6943054476,-2.1901773614131077,-0.3827,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD420MIK-36,BYD Company Limited,Mono-c-Si,0,390.0,366.0,2.01,,,24.0,10.57,50.34,10.07,41.78,0.00471422,-0.13294794000000001,44.1,1.8197383682267698,10.572192749310107,1.020110755065283e-11,0.28808536040752786,1388.6958522130565,2.477257488614687,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD395MLK-27,BYD Company Limited,Mono-c-Si,0,395.0,365.8,1.94,,,36.0,13.71,36.9,13.03,30.32,0.006855,-0.10073700000000001,46.2,1.388578480266568,13.71285064326573,3.934207871195452e-11,0.17956596544556577,863.6117110825832,8.203505007554554,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD415MIK-36,BYD Company Limited,Mono-c-Si,0,395.0,370.8,2.01,,,24.0,10.5,50.06,10.0,41.55,0.004683,-0.13220846,44.1,1.809946236764435,10.50244004949212,1.0180727562660911e-11,0.2881003186080127,1239.7508112589576,2.5174822371813144,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD400MLK-27,BYD Company Limited,Mono-c-Si,0,400.0,370.5,1.94,,,36.0,13.78,36.98,13.15,30.42,0.00689,-0.1009554,46.2,1.382818240994395,13.780004486676374,3.350675079722074e-11,0.17728413974218005,544515.3055248405,6.7517858730799265,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD410MIK-36,BYD Company Limited,Mono-c-Si,0,400.0,375.6,2.01,,,24.0,10.43,49.78,9.93,41.32,0.00465178,-0.13146898,44.1,1.7948744710018316,10.430006367041901,9.404307638627092e-12,0.28918922069880393,473730.6708696432,1.8992754209708127,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD405MIK-36,BYD Company Limited,Mono-c-Si,0,405.0,380.4,2.01,,,24.0,10.36,49.49,9.86,41.1,0.00462056,-0.13070309,44.1,1.7903978465051542,10.362938012327781,1.0202250184724659e-11,0.28594515438204055,1008.3016080185463,2.650386634361932,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD405MLK-27,BYD Company Limited,Mono-c-Si,0,405.0,375.3,1.94,,,36.0,13.85,37.06,13.27,30.52,0.006925000000000001,-0.10117380000000002,46.2,1.397706359891194,13.8500021971624,4.2285133503585655e-11,0.15862777456568347,999997.106491925,8.73681198176589,-0.364,N,2025.7.3,6/23/2025,2.0,first_pass +BYD Company Limited BYD400MIK-36,BYD Company Limited,Mono-c-Si,0,410.0,385.2,2.01,,,24.0,10.29,49.21,9.79,40.87,0.00458934,-0.12996361,44.1,1.7806090492071673,10.293181344090954,1.0182891762477426e-11,0.2859436930562841,924.8797227051399,2.692705395812188,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD410MLK-27,BYD Company Limited,Mono-c-Si,0,410.0,380.1,1.94,,,36.0,13.92,37.14,13.39,30.62,0.00696,-0.10139220000000002,46.2,1.4019437276414728,13.920004167132287,4.3490932885982716e-11,0.16797867292599172,561145.633912448,8.939972611538758,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD395MIK-36,BYD Company Limited,Mono-c-Si,0,415.0,390.0,2.01,,,24.0,10.22,48.92,9.72,40.65,0.004558120000000001,-0.12919772000000002,44.1,1.7708544691559276,10.223424257907523,1.0226208375952756e-11,0.2837258225005908,846.8042272813924,2.787019547376276,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD415MLK-27,BYD Company Limited,Mono-c-Si,0,415.0,384.8,1.94,,,36.0,14.01,37.31,13.48,30.79,0.007005000000000001,-0.10185630000000002,46.2,1.405516299576128,14.010004161580486,4.148710167680163e-11,0.1656598107535553,557718.7445432453,8.468503576274609,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD390MIK-36,BYD Company Limited,Mono-c-Si,0,420.0,394.8,2.01,,,24.0,10.15,48.64,9.65,40.42,0.0045269,-0.12845824,44.1,1.7610680666541036,10.153664103872906,1.0207667831533182e-11,0.28370719131573907,785.9023992434326,2.8309171029239373,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD520MLTK-36,BYD Company Limited,Mono-c-Si,0,520.0,482.9,2.58,,,48.0,13.37,48.52,12.64,41.17,0.007193059999999999,-0.13789384000000002,45.08,1.8830772112382372,13.375284738672418,8.528529256918407e-11,0.11930088960775583,301.82247939621425,10.821099113897317,-0.3692,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD525MLTK-36,BYD Company Limited,Mono-c-Si,0,525.0,487.7,2.58,,,48.0,13.41,48.82,12.69,41.39,0.00721458,-0.13874644,45.08,1.8929630885584465,13.41489198515039,8.361974556400393e-11,0.1229988140638602,337.1666301828546,10.613672218458113,-0.3692,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD530MLTK-36,BYD Company Limited,Mono-c-Si,0,530.0,492.4,2.58,,,48.0,13.45,49.12,12.74,41.61,0.0072361000000000005,-0.13959904,45.08,1.9028489845821157,13.45446745884266,8.200566710434166e-11,0.126667696193198,381.35339148297476,10.40878984182227,-0.3692,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD535MLTK-36,BYD Company Limited,Mono-c-Si,0,535.0,497.1,2.58,,,48.0,13.49,49.42,12.79,41.83,0.007014799999999999,-0.13392820000000003,45.9,1.8767170465638825,13.494675585139325,4.894800509722864e-11,0.13654614518136887,393.9632891427195,11.09405640921,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD540MLTK-36,BYD Company Limited,Mono-c-Si,0,540.0,501.8,2.58,,,48.0,13.53,49.72,12.84,42.05,0.0070355999999999995,-0.1347412,45.9,1.8864529940059003,13.534175106443909,4.802760609700276e-11,0.14015469161617575,454.19033922890867,10.892606201949224,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD545MLTK-36,BYD Company Limited,Mono-c-Si,0,545.0,506.6,2.58,,,48.0,13.57,50.02,12.89,42.27,0.007056400000000001,-0.13555420000000004,45.9,1.8961889590059366,13.573644752971653,4.713490014855574e-11,0.1437352390161528,535.1493665560337,10.693580498400198,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD550MLTK-36,BYD Company Limited,Mono-c-Si,0,550.0,511.4,2.58,,,48.0,13.61,50.32,12.94,42.49,0.0070772,-0.1363672,45.9,1.9059249507735296,13.613085067898265,4.626882809694881e-11,0.14728810860696753,649.7721950892098,10.496939162577283,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD555MLTK-36,BYD Company Limited,Mono-c-Si,0,555.0,516.2,2.58,,,48.0,13.65,50.62,12.99,42.71,0.007098,-0.1371802,45.9,1.915660971259985,13.652496594183866,4.542837372047715e-11,0.150813619451822,824.5657851787779,10.302639765931001,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD555NLBK-36,BYD Company Limited,Mono-c-Si,0,555.0,525.8,2.58,,,48.0,14.07,50.34,13.33,41.64,0.005628000000000001,-0.12383640000000001,44.2,1.724488135136552,14.082213485286594,2.920895907835977e-12,0.2445008987416964,281.66633603864915,-2.8799989401539747,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD560NLBK-36,BYD Company Limited,Mono-c-Si,0,560.0,530.6,2.58,,,48.0,14.15,50.47,13.41,41.77,0.005660000000000001,-0.12415620000000001,44.2,1.729139801592959,14.161859048133955,2.948282771514077e-12,0.24183965088292061,288.5586622963477,-2.8517093234584605,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD565NLBK-36,BYD Company Limited,Mono-c-Si,0,565.0,535.5,2.58,,,48.0,14.23,50.6,13.48,41.92,0.005692000000000001,-0.124476,44.2,1.7347539846800024,14.242337312127017,3.021597871278142e-12,0.237518100668262,273.95615374544553,-2.6971148514467083,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD570NLBK-36,BYD Company Limited,Mono-c-Si,0,570.0,540.3,2.58,,,48.0,14.31,50.74,13.55,42.07,0.005724,-0.12482040000000001,44.2,1.7405487426774138,14.322818036562266,3.0879099147010637e-12,0.23398404081646978,261.2187591151413,-2.5651748716623493,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD575NLBK-36,BYD Company Limited,Mono-c-Si,0,575.0,545.2,2.58,,,48.0,14.39,50.88,13.62,42.22,0.005756,-0.1251648,44.2,1.7463430464673941,14.403283192779153,3.15522429105902e-12,0.23048662696355365,249.69166839161394,-2.434014959565269,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD580NLBK-36,BYD Company Limited,Mono-c-Si,0,580.0,550.0,2.58,,,48.0,14.47,51.01,13.69,42.36,0.005788000000000001,-0.1254846,44.2,1.7517602976266733,14.483738395522165,3.2217826609742108e-12,0.22712171159175204,239.21651896126133,-2.3080698929758348,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +BYD Company Limited BYD645MSTK-33,BYD Company Limited,Mono-c-Si,0,645.0,603.0,3.0,,,44.0,18.13,45.32,17.1,37.77,0.009246299999999999,-0.1164724,45.4,1.6748442654514957,18.14531402673766,3.1648487028559626e-11,0.13707099702628864,162.27588185706634,10.482362312102746,-0.34,N,2025.7.3,6/23/2025,4.0,bootstrapping +BYD Company Limited BYD650MSTK-33,BYD Company Limited,Mono-c-Si,0,650.0,607.8,3.0,,,44.0,18.17,45.45,17.18,37.86,0.009266700000000001,-0.11680650000000001,45.4,1.677267899555243,18.1824182803149,3.0613086520307187e-11,0.1385227143048432,202.68166579852561,10.153465812353168,-0.34,N,2025.7.3,6/23/2025,4.0,bootstrapping +BYD Company Limited BYD655MSTK-33,BYD Company Limited,Mono-c-Si,0,655.0,612.6,3.0,,,44.0,18.21,45.58,17.27,37.95,0.0092871,-0.1171406,45.4,1.6792510982837585,18.21873422667589,2.9423989765870014e-11,0.13998440760012046,291.85366805623903,9.76627371600763,-0.34,N,2025.7.3,6/23/2025,4.0,bootstrapping +BYD Company Limited BYD660MSTK-33,BYD Company Limited,Mono-c-Si,0,660.0,617.4,3.0,,,44.0,18.24,45.72,17.36,38.04,0.009302399999999999,-0.1175004,45.4,1.6810165326792132,18.244266887178238,2.8019740781178435e-11,0.14210669840883475,607.4747549184794,9.300243064090365,-0.34,N,2025.7.3,6/23/2025,4.0,bootstrapping +BYD Company Limited BYD665MSTK-33,BYD Company Limited,Mono-c-Si,0,665.0,622.2,3.0,,,44.0,18.27,45.85,17.45,38.12,0.0093177,-0.11783450000000001,45.4,1.6827995910512041,18.270002624912355,2.684330011134951e-11,0.143667728970518,999999.7535480077,8.890400352277158,-0.34,N,2025.7.3,6/23/2025,2.0,bootstrapping +Caterpillar Inc PVT105,Caterpillar Inc,Thin Film,0,105.0,97.4,0.72,1.2,0.6,216.0,1.74,86.0,1.55,67.8,0.0007481999999999999,-0.23048000000000002,47.0,3.0551907278426635,1.757089085393143,9.586433762565275e-13,5.700160856451289,580.386817471459,-3.2816567726554697,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT105 ARC,Caterpillar Inc,Thin Film,0,105.0,97.4,0.72,1.2,0.6,216.0,1.74,86.0,1.55,67.8,0.0007481999999999999,-0.23048000000000002,47.0,3.0551907278426635,1.757089085393143,9.586433762565275e-13,5.700160856451289,580.386817471459,-3.2816567726554697,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT107,Caterpillar Inc,Thin Film,0,107.5,99.7,0.72,1.2,0.6,216.0,1.75,86.6,1.57,68.6,0.0007525,-0.23208800000000002,47.0,4.497174433605887,1.7567588031659906,7.214514786836774e-09,3.6148372262763186,935.9624483356683,99.99999826586864,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT107 ARC,Caterpillar Inc,Thin Film,0,107.5,99.7,0.72,1.2,0.6,216.0,1.75,86.6,1.57,68.6,0.0007525,-0.23208800000000002,47.0,4.497174433605887,1.7567588031659906,7.214514786836774e-09,3.6148372262763186,935.9624483356683,99.99999826586864,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT110,Caterpillar Inc,Thin Film,0,110.0,102.1,0.72,1.2,0.6,216.0,1.75,87.2,1.59,69.4,0.0007525,-0.23369600000000001,47.0,3.083448732945909,1.76115213755861,8.648340753821517e-13,5.233498315618659,821.24364008945,-4.2034035694308916,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT110 ARC,Caterpillar Inc,Thin Film,0,110.0,102.1,0.72,1.2,0.6,216.0,1.75,87.2,1.59,69.4,0.0007525,-0.23369600000000001,47.0,3.083448732945909,1.76115213755861,8.648340753821517e-13,5.233498315618659,821.24364008945,-4.2034035694308916,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT112,Caterpillar Inc,Thin Film,0,112.5,104.5,0.72,1.2,0.6,216.0,1.75,87.7,1.6,70.2,0.0007525,-0.23503600000000002,47.0,3.1010689674307415,1.7592033911725393,8.702678310025423e-13,4.963606213676088,943.8163307213069,-4.17444523491836,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT112 ARC,Caterpillar Inc,Thin Film,0,112.5,104.5,0.72,1.2,0.6,216.0,1.75,87.7,1.6,70.2,0.0007525,-0.23503600000000002,47.0,3.1010689674307415,1.7592033911725393,8.702678310025423e-13,4.963606213676088,943.8163307213069,-4.17444523491836,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT115,Caterpillar Inc,Thin Film,0,115.0,105.2,0.72,1.2,0.6,216.0,1.78,87.8,1.63,70.5,0.0008081200000000001,-0.3115144,46.3,3.4392137958481594,1.7870936672631421,1.3954203145663427e-11,4.287597641928349,1075.8784759221192,-9.694368747908243,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT115 ARC,Caterpillar Inc,Thin Film,0,115.0,105.2,0.72,1.2,0.6,216.0,1.78,87.8,1.63,70.5,0.0008081200000000001,-0.3115144,46.3,3.4392137958481594,1.7870936672631421,1.3954203145663427e-11,4.287597641928349,1075.8784759221192,-9.694368747908243,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT117,Caterpillar Inc,Thin Film,0,117.5,107.5,0.72,1.2,0.6,216.0,1.79,88.2,1.65,71.2,0.00081266,-0.3129336,46.3,3.4533327813132653,1.7955354319189605,1.397398166525051e-11,4.0135856908542715,1297.878579117281,-9.742699876091324,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVT117 ARC,Caterpillar Inc,Thin Film,0,117.5,107.5,0.72,1.2,0.6,216.0,1.79,88.2,1.65,71.2,0.00081266,-0.3129336,46.3,3.4533327813132653,1.7955354319189605,1.397398166525051e-11,4.0135856908542715,1297.878579117281,-9.742699876091324,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC345MP03HA,Caterpillar Inc,Mono-c-Si,0,345.0,322.0,1.77,,,60.0,11.06,40.2,10.09,34.2,0.004424,-0.10693200000000001,45.2,1.5111998228164025,11.080640717809748,2.9271558116787247e-11,0.11970298639496126,64.1409394862886,10.68460888908741,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC350MP03HA,Caterpillar Inc,Mono-c-Si,0,350.0,326.8,1.77,,,60.0,11.16,40.4,10.18,34.4,0.004464,-0.107464,45.2,1.5195139554784252,11.180289889719349,2.99439615627122e-11,0.11581786936356875,63.703028578957905,10.80820072218361,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC355MP03HA,Caterpillar Inc,Mono-c-Si,0,355.0,331.6,1.77,,,60.0,11.25,40.6,10.27,34.6,0.0045000000000000005,-0.10799600000000001,45.2,1.5270972161469873,11.269588495579438,3.024286292448575e-11,0.11229766708165156,64.49442490631887,10.822307151048834,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC360MP03,Caterpillar Inc,Mono-c-Si,0,360.0,336.0,1.88,,,72.0,9.87,47.84,9.23,39.01,0.0037505999999999998,-0.12581920000000002,44.48,1.7530541835143334,9.888398396385682,1.3577045335481152e-11,0.3728213704703303,200.00367797506522,6.078455414534571,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC365MP03,Caterpillar Inc,Mono-c-Si,0,365.0,340.8,1.88,,,72.0,9.9,48.13,9.28,39.34,0.003762,-0.12658190000000002,44.48,1.7638297301137396,9.915848909750093,1.368445212787812e-11,0.36230509228661306,226.31338626816975,6.110947695785881,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC365MP03H,Caterpillar Inc,Mono-c-Si,0,365.0,343.3,1.936,,,72.0,9.71,48.4,9.13,40.0,0.0039811000000000004,-0.129228,42.59,1.7755442497745193,9.721591911244674,1.383525202881158e-11,0.3173989955921277,265.8702434256147,4.721423804181126,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC365MP03HA,Caterpillar Inc,Mono-c-Si,0,365.0,341.1,1.77,,,60.0,11.41,41.0,10.43,35.0,0.004564,-0.10906000000000002,45.2,1.542410182784778,11.42825556850408,3.0859269044313114e-11,0.10558403761803749,65.99158340992919,10.871475718920136,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC370MP03,Caterpillar Inc,Mono-c-Si,0,370.0,345.6,1.88,,,72.0,9.93,48.4,9.32,39.69,0.0037733999999999997,-0.127292,44.48,1.7755860123057483,9.944271149296371,1.4140769894916348e-11,0.3472503806161329,241.6200868176698,6.363314791038329,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC370MP03H,Caterpillar Inc,Mono-c-Si,0,370.0,348.1,1.936,,,72.0,9.79,48.6,9.21,40.2,0.0040139,-0.12976200000000002,42.59,1.7832178866281938,9.801179045728373,1.4028582637888245e-11,0.3118042096250647,273.0611631607304,4.767741300971173,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC370MP03HA,Caterpillar Inc,Mono-c-Si,0,370.0,345.9,1.77,,,60.0,11.5,41.2,10.52,35.2,0.0046,-0.10959200000000001,45.2,1.5500019096523567,11.517597107661977,3.1163791194872414e-11,0.10223285439116882,66.81085610877976,10.886215810867267,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC375MP03,Caterpillar Inc,Mono-c-Si,0,375.0,350.4,1.88,,,72.0,9.96,48.71,9.36,40.08,0.0037848,-0.1281073,44.48,1.788953431862155,9.972762692591898,1.4638016382206307e-11,0.331739729200223,258.8895485238465,6.631555065341871,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC375MP03H,Caterpillar Inc,Mono-c-Si,0,375.0,352.9,1.936,,,72.0,9.87,48.8,9.28,40.4,0.0040467,-0.130296,42.59,1.7918218473512795,9.881583368718386,1.4407308505082945e-11,0.306226012113944,260.9302035063924,4.927878298532354,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC380MP03,Caterpillar Inc,Mono-c-Si,0,380.0,355.2,1.88,,,72.0,10.0,49.03,9.4,40.41,0.0038,-0.1289489,44.48,1.8019915228114685,10.01238238875931,1.49871253512074e-11,0.32442473405955247,262.0049671751278,6.800331859841528,-0.349,N,2025.7.3,6/23/2025,4.0,bootstrapping +Caterpillar Inc PVC380MP03H,Caterpillar Inc,Mono-c-Si,0,380.0,357.7,1.936,,,72.0,9.96,49.0,9.36,40.6,0.004083600000000001,-0.13083,42.59,1.8003684323979054,9.971936380199708,1.479588108027601e-11,0.30043538194921643,250.69044117814633,5.079700055882467,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC385MP03H,Caterpillar Inc,Mono-c-Si,0,385.0,362.6,1.936,,,72.0,10.03,49.2,9.43,40.8,0.0041123,-0.131364,42.59,1.8080980655384384,10.041563024111326,1.4992264512213083e-11,0.2954106030133819,256.24510816847726,5.13080974669038,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC425MB03H,Caterpillar Inc,Mono-c-Si,1,425.0,398.2,2.11,,,72.0,11.22,48.7,10.52,40.4,0.0046002000000000005,-0.12613300000000002,44.8,1.765029440252233,11.23597430882295,1.1415892532401837e-11,0.2653813228775244,186.39795217757174,5.07916493856684,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC425MP03H,Caterpillar Inc,Mono-c-Si,0,425.0,397.5,2.12,,,72.0,11.23,48.3,10.5,40.5,0.0046043,-0.127995,45.1,1.7706019451201997,11.245189988226574,1.5557702801018257e-11,0.2138203083715877,158.0779414848141,5.309143787655106,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC430MB03H,Caterpillar Inc,Mono-c-Si,1,430.0,403.0,2.11,,,72.0,11.3,48.9,10.6,40.6,0.004633,-0.126651,44.8,1.772624734577569,11.31551597049975,1.1564972758718278e-11,0.2609256717489563,190.02743658279687,5.127640246209294,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC430MP03H,Caterpillar Inc,Mono-c-Si,0,430.0,402.3,2.12,,,72.0,11.31,48.5,10.57,40.7,0.004637100000000001,-0.128525,45.1,1.7790497160785657,11.32537314661119,1.5929298152120795e-11,0.2096208022947828,154.21768687585356,5.4525829283566365,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC435MB03H,Caterpillar Inc,Mono-c-Si,1,435.0,407.8,2.11,,,72.0,11.36,49.1,10.66,40.8,0.0046576,-0.127169,44.8,1.780319823788851,11.375135330908641,1.171070645627112e-11,0.2569796926451043,192.87911530884293,5.188275909621149,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC435MP03H,Caterpillar Inc,Mono-c-Si,0,435.0,407.1,2.12,,,72.0,11.39,48.7,10.64,40.9,0.0046699,-0.12905500000000003,45.1,1.7874968618556537,11.405542803689757,1.6306291004335413e-11,0.20547697216891703,150.57661193623903,5.594771082871409,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC440MB03H,Caterpillar Inc,Mono-c-Si,1,440.0,412.6,2.11,,,72.0,11.45,49.2,10.73,41.0,0.0046945,-0.127428,44.8,1.7876565936776858,11.465700926080746,1.2475809757389594e-11,0.24287753496983178,177.11997382937432,5.67033923411089,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC440MP03H,Caterpillar Inc,Mono-c-Si,0,440.0,411.9,2.12,,,72.0,11.46,48.9,10.71,41.1,0.004698600000000001,-0.129585,45.1,1.7951666055316327,11.475127720715053,1.6495774477805363e-11,0.201688491560652,152.78905092110557,5.639651679653171,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC445MB03H,Caterpillar Inc,Mono-c-Si,1,445.0,417.4,2.11,,,72.0,11.52,49.4,10.8,41.2,0.0047232,-0.127946,44.8,1.7952995585506628,11.535287602646617,1.2629740745353623e-11,0.23887957464576332,180.00812630907944,5.7218817751590425,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC445MP03H,Caterpillar Inc,Mono-c-Si,0,445.0,416.7,2.12,,,72.0,11.53,49.1,10.78,41.3,0.0047273,-0.130115,45.1,1.7672064016421838,11.530005358311554,9.894704511017995e-12,0.2049164016517749,440940.83293849806,1.191995485909948,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC450MB03H,Caterpillar Inc,Mono-c-Si,1,450.0,422.2,2.11,,,72.0,11.58,49.6,10.87,41.4,0.0047478,-0.12846400000000002,44.8,1.80219332119643,11.594207371909429,1.264093838893258e-11,0.23521965183016758,191.72043885667352,5.679599761929699,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC450MP03H,Caterpillar Inc,Mono-c-Si,0,450.0,421.5,2.12,,,72.0,11.6,49.3,10.85,41.5,0.004756,-0.130645,45.1,1.7752739600842165,11.60000522564254,1.0091116050212471e-11,0.20110860376726208,446427.7923063699,1.3041939824257833,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC455MB03H,Caterpillar Inc,Mono-c-Si,1,455.0,427.0,2.11,,,72.0,11.65,49.8,10.93,41.6,0.0047765,-0.128982,44.8,1.7813080862051711,11.650006383063628,8.409271846591846e-12,0.2368100132833699,432214.1022740782,2.099231182516898,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Caterpillar Inc PVC455MP03H,Caterpillar Inc,Mono-c-Si,0,455.0,426.3,2.12,,,72.0,11.66,49.5,10.92,41.7,0.0047806,-0.131175,45.1,1.8174085763341632,11.673388469172759,1.6876366909758283e-11,0.19090780574189858,166.2613546720686,5.678611299004972,-0.334,N,2025.7.3,6/23/2025,4.0,bootstrapping +Centrosolar America DP36 130,Centrosolar America,Multi-c-Si,0,130.0,114.7,1.010848,1.019,0.992,36.0,8.42,21.69,7.92,16.41,0.005052,-0.078084,46.7,0.9190639705527304,8.45245924990926,4.759809049302775e-10,0.34583678223696224,999999.951915509,4.009560418688984,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP36 135,Centrosolar America,Multi-c-Si,0,135.0,119.2,1.010848,1.019,0.992,36.0,8.48,21.9,7.98,16.92,0.005088,-0.07884,46.7,0.9385162380726451,8.493954520468602,6.236989120101484e-10,0.29416697818821896,999999.9550816037,6.2669037324773385,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America VS-135C1,Centrosolar America,Thin Film,0,135.0,125.0,1.086336,1.656,0.656,100.0,3.43,59.5,3.02,44.7,0.00022329300000000003,-0.17017,47.0,1.9634162553928214,3.4893697326621544,2.1667576340434567e-13,2.940582229094102,169.8878637127962,-23.703314750641823,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-135C2,Centrosolar America,Thin Film,0,135.0,125.4,1.086336,1.656,0.656,133.0,2.51,79.8,2.19,61.64,0.000198792,-0.232218,46.9,2.6574887247597663,2.551110011082904,2.0588078200256533e-13,4.542859091970121,277.36738630272316,-23.336047151497258,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP36 140,Centrosolar America,Multi-c-Si,0,140.0,123.7,1.010848,1.019,0.992,36.0,8.53,22.15,8.03,17.43,0.005118,-0.07973999999999999,46.7,0.9587444888278004,8.530144647174621,7.894361640108497e-10,0.24883985191560248,14675.00739879943,8.27858220171185,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-140C1,Centrosolar America,Thin Film,0,140.0,129.8,1.086336,1.656,0.656,100.0,3.44,60.6,3.05,46.0,0.000223944,-0.17331599999999997,47.0,2.003680453772081,3.4908239410453925,2.3235253791950696e-13,2.7932377808561064,189.05928532447402,-23.292975378938166,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-140C2,Centrosolar America,Thin Film,0,140.0,130.1,1.086336,1.656,0.656,133.0,2.51,79.95,2.23,62.78,0.000198792,-0.23265450000000001,46.9,2.6615929431305116,2.5387750140858203,2.0788963541695546e-13,3.9816932047744977,347.3169436925623,-23.326864545589466,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP36 145,Centrosolar America,Multi-c-Si,0,145.0,128.3,1.010848,1.019,0.992,36.0,8.6,22.37,8.1,17.9,0.00516,-0.080532,46.7,0.9776890982440002,8.601284070691177,9.928276329174831e-10,0.20551237976938086,1376.4136605546717,10.243895075493606,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-145C1,Centrosolar America,Thin Film,0,145.0,134.5,1.086336,1.656,0.656,100.0,3.44,61.5,3.09,46.9,0.000223944,-0.17589,47.0,2.026553594724652,3.480057392074381,2.1281730362141694e-13,2.7322821594767714,234.63960450104545,-23.896617888685483,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-145C2,Centrosolar America,Thin Film,0,145.0,134.8,1.086336,1.656,0.656,133.0,2.52,80.45,2.27,63.87,0.000199584,-0.23410949999999997,46.9,2.675497672282235,2.541286012980169,2.054936609480164e-13,3.614535328918489,427.91616447462917,-23.469850758017813,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP36 150,Centrosolar America,Multi-c-Si,0,150.0,132.8,1.010848,1.019,0.992,36.0,8.63,22.51,8.13,18.45,0.005178,-0.08103600000000001,46.7,0.9978455619476222,8.632182088035302,1.370956248368346e-09,0.14201697134380184,561.6676748239704,13.152063821512272,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-150C1,Centrosolar America,Thin Film,0,150.0,139.2,1.086336,1.656,0.656,100.0,3.45,62.5,3.12,48.1,0.00022459500000000001,-0.17875,47.0,2.0624624837533627,3.4835264003199713,2.244640720916336e-13,2.5959806967472003,267.136743666242,-23.594676219503935,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-150C2,Centrosolar America,Thin Film,0,150.0,139.5,1.086336,1.656,0.656,133.0,2.52,81.35,2.3,65.22,0.000199584,-0.23672849999999998,46.9,2.7020007829365995,2.5351783582582397,2.0068849505377477e-13,3.3205928620764,551.3042894628212,-23.66420241123395,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-155C1,Centrosolar America,Thin Film,0,155.0,143.9,1.086336,1.656,0.656,100.0,3.46,63.4,3.15,49.2,0.000225246,-0.18132399999999999,47.0,2.0943743140204347,3.4877706113454376,2.3404475792546483e-13,2.4671899631606182,307.39248599575575,-23.36603525541606,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-155C2,Centrosolar America,Thin Film,0,155.0,144.2,1.086336,1.656,0.656,133.0,2.52,82.85,2.33,66.52,0.000199584,-0.2410935,46.9,2.7381134587218705,2.5307921209616753,1.7522952074974894e-13,3.3194986505094333,775.1151633414939,-24.571059711008658,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America VS-160C1,Centrosolar America,Thin Film,0,160.0,148.6,1.086336,1.656,0.656,100.0,3.47,64.5,3.18,50.3,0.00022589700000000002,-0.18447,47.0,2.129641366479862,3.493068700605797,2.3284652537399365e-13,2.4051472562032963,361.7828817408645,-23.43938248951242,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP48 175,Centrosolar America,Multi-c-Si,0,175.0,154.5,1.325312,1.336,0.992,48.0,8.42,29.01,7.92,22.1,0.005052,-0.104436,46.7,1.2338187493568245,8.444891173063064,5.191597989582136e-10,0.4396767889451679,999999.9670202956,4.74996185400939,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP48 180,Centrosolar America,Multi-c-Si,0,180.0,159.0,1.325312,1.336,0.992,48.0,8.48,29.2,7.98,22.56,0.005088,-0.10511999999999999,46.7,1.25135535203142,8.493960745391172,6.237031123285393e-10,0.39222246782182896,999999.9680880794,6.266958715194018,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP48 185,Centrosolar America,Multi-c-Si,0,185.0,163.5,1.325312,1.336,0.992,48.0,8.53,29.49,8.03,23.04,0.005118,-0.106164,46.7,1.2714226152662487,8.535878124698488,7.211197536932541e-10,0.35581973150690155,999999.9687956444,7.480698542133426,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP48 190,Centrosolar America,Multi-c-Si,0,190.0,168.1,1.325312,1.336,0.992,48.0,8.57,29.73,8.07,23.54,0.005142,-0.107028,46.7,1.291390377084558,8.570538437285814,8.600167994852971e-10,0.3109276771228567,4948.913230253128,8.993547292474538,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP48 195,Centrosolar America,Multi-c-Si,0,195.0,172.7,1.325312,1.336,0.992,48.0,8.6,29.92,8.1,24.07,0.00516,-0.107712,46.7,1.3118394694045028,8.601647107515529,1.0670999826392416e-09,0.2559551921406603,1336.416015188975,10.894097233543796,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP48 200,Centrosolar America,Multi-c-Si,0,200.0,177.2,1.325312,1.336,0.992,48.0,8.63,30.12,8.13,24.6,0.005178,-0.108432,46.7,1.3323767314625476,8.632117859845438,1.307746594024798e-09,0.20279730596032133,826.3737049380172,12.71671090962342,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP54 200,Centrosolar America,Multi-c-Si,0,200.0,176.6,1.4830400000000001,1.495,0.992,54.0,8.42,32.8,7.92,25.25,0.005052,-0.11807999999999998,46.7,1.4029185397110302,8.433821496732536,5.919576244427773e-10,0.4576236213120663,999999.9724356463,5.879157634984293,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP54 205,Centrosolar America,Multi-c-Si,0,205.0,181.2,1.4830400000000001,1.495,0.992,54.0,8.47,33.01,7.97,25.72,0.005082000000000001,-0.118836,46.7,1.4211169248408386,8.47479583960076,6.922211241821569e-10,0.4117167559188255,999999.973074937,7.187222861826163,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP54 210,Centrosolar America,Multi-c-Si,0,210.0,185.7,1.4830400000000001,1.495,0.992,54.0,8.5,33.23,8.0,26.25,0.0051,-0.11962799999999998,46.7,1.4418060931334313,8.500808904866181,8.310294630776457e-10,0.3595468592147186,3778.1584892879146,8.763908915383174,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP54 215,Centrosolar America,Multi-c-Si,0,215.0,190.3,1.4830400000000001,1.495,0.992,54.0,8.52,33.44,8.02,26.81,0.005111999999999999,-0.12038399999999999,46.7,1.463652755268754,8.521903951766664,1.0161814961240068e-09,0.3023437464881,1352.9625027921966,10.539014410772621,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP54 220,Centrosolar America,Multi-c-Si,0,220.0,194.8,1.4830400000000001,1.495,0.992,54.0,8.55,33.66,8.05,27.33,0.00513,-0.12117599999999998,46.7,1.4842411950266843,8.552324574623794,1.2055873394940598e-09,0.25247338528555685,928.6219158997501,12.05785712347082,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 220,Centrosolar America,Multi-c-Si,0,220.0,197.6,1.6397760000000001,1.653,0.992,60.0,8.46,36.26,7.96,27.64,0.0043146,-0.1200206,45.9,1.4563573199876347,8.461085092683454,1.3015919896753738e-10,0.5657766086064154,999999.9755835012,2.0364921956594393,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America DP54 225,Centrosolar America,Multi-c-Si,0,225.0,199.4,1.4830400000000001,1.495,0.992,54.0,8.6,33.8,8.1,27.78,0.00516,-0.12167999999999998,46.7,1.5009507907185795,8.602322014864646,1.4204774580281692e-09,0.20277461666414157,751.0132998450268,13.513577573691977,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 225,Centrosolar America,Multi-c-Si,0,225.0,202.2,1.6397760000000001,1.653,0.992,60.0,8.48,36.4,7.98,28.2,0.0043248,-0.12048400000000001,45.9,1.4753252361219225,8.482215012614043,1.6307634018854303e-10,0.49908384482193674,1910.7052275612414,3.893693656158151,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 230,Centrosolar America,Mono-c-Si,0,230.0,208.1,1.6397760000000001,1.653,0.992,60.0,8.5,36.2,8.0,28.8,0.00637415,-0.11728800000000002,45.6,1.4876912966278697,8.504503256054978,2.287704672994993e-10,0.3838303517464133,724.4889630269051,8.794169252016749,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP54 230,Centrosolar America,Multi-c-Si,0,230.0,204.0,1.4830400000000001,1.495,0.992,54.0,8.66,34.02,8.16,28.19,0.005195999999999999,-0.12247200000000001,46.7,1.5177023513835073,8.662098393334126,1.5858626748851989e-09,0.1694521510494714,699.3242922139076,14.473554262029387,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 230,Centrosolar America,Multi-c-Si,0,230.0,206.8,1.6397760000000001,1.653,0.992,60.0,8.5,36.68,8.0,28.75,0.004335,-0.12141080000000001,45.9,1.4964574346533512,8.50336233963631,1.9180546348004985e-10,0.4523372906922447,1143.510152034017,5.245203706161813,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 235,Centrosolar America,Mono-c-Si,0,235.0,212.8,1.6397760000000001,1.653,0.992,60.0,8.6,36.5,8.0,29.4,0.00644914,-0.11826,45.6,1.519871231814827,8.614910329214432,3.131771872351029e-10,0.32937765700383687,189.97891791680138,11.537077156218835,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 235,Centrosolar America,Multi-c-Si,0,235.0,211.4,1.6397760000000001,1.653,0.992,60.0,8.52,36.98,8.02,29.3,0.0043452,-0.1224038,45.9,1.5178962243250576,8.52406593261838,2.227759347651711e-10,0.40848248546401794,855.9592104614187,6.5062144073999475,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 235 BW,Centrosolar America,Multi-c-Si,0,235.0,208.1,1.634788,1.658,0.986,60.0,8.69,37.44,8.07,29.74,0.00570064,-0.1250496,47.5,1.6099043930562904,8.705733759665048,6.77395207935918e-10,0.37990860121426007,209.82948627087458,15.153798692095709,-0.4793,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 235 SW,Centrosolar America,Multi-c-Si,0,235.0,208.1,1.634788,1.658,0.986,60.0,8.69,37.44,8.07,29.74,0.00570064,-0.1250496,47.5,1.6099043930562904,8.705733759665048,6.77395207935918e-10,0.37990860121426007,209.82948627087458,15.153798692095709,-0.4793,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 240,Centrosolar America,Mono-c-Si,0,240.0,217.4,1.6397760000000001,1.653,0.992,60.0,8.6,36.8,8.1,29.7,0.00644914,-0.119232,45.6,1.5241726191431932,8.604378951580925,2.793045416794327e-10,0.32406006124281433,636.43486485192,10.465196711266637,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 240,Centrosolar America,Multi-c-Si,0,240.0,216.0,1.6397760000000001,1.653,0.992,60.0,8.55,37.16,8.05,29.81,0.0043605,-0.1229996,45.9,1.535927724560689,8.554456475998048,2.6433845561174063e-10,0.3551086940285755,681.2962641112626,7.958819119647454,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 240 BW,Centrosolar America,Multi-c-Si,0,240.0,212.7,1.634788,1.658,0.986,60.0,8.82,37.64,8.2,29.9,0.005785920000000001,-0.1257176,47.5,1.6175654246962363,8.834827633498493,6.792301725490923e-10,0.3761515568403573,223.74830346566935,15.036412853236229,-0.4793,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 240 SW,Centrosolar America,Multi-c-Si,0,240.0,212.7,1.634788,1.658,0.986,60.0,8.82,37.64,8.2,29.9,0.005785920000000001,-0.1257176,47.5,1.6175654246962363,8.834827633498493,6.792301725490923e-10,0.3761515568403573,223.74830346566935,15.036412853236229,-0.4793,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 245,Centrosolar America,Mono-c-Si,0,245.0,222.0,1.6397760000000001,1.653,0.992,60.0,8.7,37.1,8.1,30.3,0.0065241299999999995,-0.120204,45.6,1.5565244982669681,8.71246271932672,3.7909716429709195e-10,0.2702542588585858,188.65965307996635,13.174506747050728,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 245,Centrosolar America,Multi-c-Si,0,245.0,220.6,1.6397760000000001,1.653,0.992,60.0,8.58,37.4,8.08,30.32,0.0043758,-0.123794,45.9,1.5549734024117108,8.584489725990034,3.054342445727736e-10,0.3098299437335797,592.0944149216498,9.196930520455401,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 245 BW,Centrosolar America,Multi-c-Si,0,245.0,217.2,1.634788,1.658,0.986,60.0,8.82,37.64,8.2,29.9,0.005785920000000001,-0.1257176,47.5,1.6175654246962363,8.834827633498493,6.792301725490923e-10,0.3761515568403573,223.74830346566935,15.036412853236229,-0.4793,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 245 SW,Centrosolar America,Multi-c-Si,0,245.0,217.2,1.634788,1.658,0.986,60.0,8.82,37.64,8.2,29.9,0.005785920000000001,-0.1257176,47.5,1.6175654246962363,8.834827633498493,6.792301725490923e-10,0.3761515568403573,223.74830346566935,15.036412853236229,-0.4793,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6 245xx,Centrosolar America,Multi-c-Si,0,245.0,220.4,1.6335,1.65,0.99,60.0,8.64,37.3,8.13,30.3,0.0044063999999999996,-0.11376499999999999,48.2,1.4852567104503311,8.647098433425853,1.060003178718739e-10,0.3154245844211609,383.92536213886694,8.827847052526534,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6S 245xx,Centrosolar America,Multi-c-Si,0,245.0,220.4,1.6335,1.65,0.99,60.0,8.64,37.3,8.13,30.3,0.0044063999999999996,-0.11376499999999999,48.2,1.4852567104503311,8.647098433425853,1.060003178718739e-10,0.3154245844211609,383.92536213886694,8.827847052526534,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 250,Centrosolar America,Mono-c-Si,0,250.0,226.7,1.6397760000000001,1.653,0.992,60.0,8.7,37.4,8.2,30.6,0.0065241299999999995,-0.121176,45.6,1.5605170532569754,8.703980570874341,3.3729746415534876e-10,0.2659089551653577,581.1750751856598,12.06438613139859,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 250,Centrosolar America,Multi-c-Si,0,250.0,225.3,1.6397760000000001,1.653,0.992,60.0,8.61,37.65,8.11,30.83,0.004391099999999999,-0.12462150000000001,45.9,1.5741532876158044,8.61430745709777,3.5022594720328094e-10,0.2662234276998279,532.1432584545946,10.3813508475736,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 250BW,Centrosolar America,Multi-c-Si,0,250.0,222.3,1.622912,1.636,0.992,60.0,8.79,37.41,8.34,29.98,0.0034281,-0.127194,47.1,1.5714449168578324,8.82339041005155,4.043606018543207e-10,0.3436324351656363,999999.9231464808,8.594991266024604,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP6 250SW,Centrosolar America,Multi-c-Si,0,250.0,222.3,1.622912,1.636,0.992,60.0,8.79,37.41,8.34,29.98,0.0034281,-0.127194,47.1,1.5714449168578324,8.82339041005155,4.043606018543207e-10,0.3436324351656363,999999.9231464808,8.594991266024604,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America TP6 250xx,Centrosolar America,Multi-c-Si,0,250.0,225.0,1.6335,1.65,0.99,60.0,8.76,37.5,8.24,30.5,0.0044675999999999995,-0.114375,48.2,1.494498374097324,8.767438001107145,1.0974407206267692e-10,0.3074314954178503,362.07311472453836,9.013309166364916,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6S 250xx,Centrosolar America,Multi-c-Si,0,250.0,225.0,1.6335,1.65,0.99,60.0,8.76,37.5,8.24,30.5,0.0044675999999999995,-0.114375,48.2,1.494498374097324,8.767438001107145,1.0974407206267692e-10,0.3074314954178503,362.07311472453836,9.013309166364916,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 255,Centrosolar America,Mono-c-Si,0,255.0,231.4,1.6397760000000001,1.653,0.992,60.0,8.8,37.9,8.2,31.1,0.006599120000000001,-0.122796,45.6,1.5936912551727582,8.81132244844361,4.0487632856096716e-10,0.25197330626571524,195.83797142714687,13.673526631057422,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 255,Centrosolar America,Multi-c-Si,0,255.0,226.2,1.6397760000000001,1.653,0.992,60.0,8.66,37.9,8.16,31.25,0.005195999999999999,-0.13644,46.7,1.685832563510911,8.662117501057217,1.4853876485149641e-09,0.2113077493547877,864.1919585352726,13.862643954494139,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 255BW,Centrosolar America,Multi-c-Si,0,255.0,226.9,1.622912,1.636,0.992,60.0,8.94,37.54,8.43,30.25,0.0034866,-0.127636,47.1,1.58406273078486,8.942563339610546,4.5462935551370106e-10,0.31697888570199473,1105.5085007107843,9.519010664514774,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 255SW,Centrosolar America,Multi-c-Si,0,255.0,226.9,1.622912,1.636,0.992,60.0,8.94,37.54,8.43,30.25,0.0034866,-0.127636,47.1,1.58406273078486,8.942563339610546,4.5462935551370106e-10,0.31697888570199473,1105.5085007107843,9.519010664514774,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 255BW,Centrosolar America,Multi-c-Si,0,255.0,230.6,1.6111239999999998,1.634,0.986,60.0,8.82,37.54,8.25,30.91,0.003528,-0.123882,45.5,1.5619681054041743,8.828989786862774,3.1638426996591995e-10,0.23869587181441046,234.18773179303756,9.761921412917841,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 255SW,Centrosolar America,Multi-c-Si,0,255.0,230.6,1.6111239999999998,1.634,0.986,60.0,8.82,37.54,8.25,30.91,0.003528,-0.123882,45.5,1.5619681054041743,8.828989786862774,3.1638426996591995e-10,0.23869587181441046,234.18773179303756,9.761921412917841,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6 255xx,Centrosolar America,Multi-c-Si,0,255.0,229.6,1.6335,1.65,0.99,60.0,8.89,38.1,8.34,30.6,0.0045339,-0.116205,48.2,1.5099498018031998,8.900407586664917,9.659780140468794e-11,0.3621342213021225,309.3294875284176,7.7752470885520415,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6S 255xx,Centrosolar America,Multi-c-Si,0,255.0,229.6,1.6335,1.65,0.99,60.0,8.89,38.1,8.34,30.6,0.0045339,-0.116205,48.2,1.5099498018031998,8.900407586664917,9.659780140468794e-11,0.3621342213021225,309.3294875284176,7.7752470885520415,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP60 260-C1,Centrosolar America,Mono-c-Si,0,260.0,235.3,1.6268799999999999,1.64,0.992,60.0,9.16,38.3,8.56,30.95,0.00379224,-0.13722890000000001,45.7,1.5743251191944307,9.172177761685607,2.4507548017508304e-10,0.3156255681816209,237.4106659374799,-1.3258869015817167,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 260,Centrosolar America,Mono-c-Si,0,260.0,236.0,1.6397760000000001,1.653,0.992,60.0,8.8,38.2,8.3,31.4,0.006599120000000001,-0.12376800000000003,45.6,1.597508716636231,8.803537363526575,3.6028088516954554e-10,0.24799472650081464,616.9437167743549,12.559620388646511,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 260,Centrosolar America,Multi-c-Si,0,260.0,234.4,1.6397760000000001,1.653,0.992,60.0,8.7,38.28,8.2,31.71,0.006440609999999999,-0.12976920000000003,46.5,1.6268959159161476,8.703373957703175,5.217387582470234e-10,0.21159005485297644,545.6008157314199,10.926983115523965,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 260BB,Centrosolar America,Mono-c-Si,0,260.0,236.5,1.6111239999999998,1.634,0.986,60.0,9.01,38.22,8.49,30.63,0.00556818,-0.1158066,45.4,1.5502381136449206,9.014798273418156,1.757877496855317e-10,0.3575830264362269,671.4548363435356,13.578648199056499,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 260BW,Centrosolar America,Multi-c-Si,0,260.0,231.5,1.622912,1.636,0.992,60.0,9.09,37.65,8.52,30.51,0.0035451,-0.12801,47.1,1.5989987650824264,9.09769570501392,5.342381496910254e-10,0.28855828165451075,340.83888785193426,10.830175728301262,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 260SW,Centrosolar America,Multi-c-Si,0,260.0,231.5,1.622912,1.636,0.992,60.0,9.09,37.65,8.52,30.51,0.0035451,-0.12801,47.1,1.5989987650824264,9.09769570501392,5.342381496910254e-10,0.28855828165451075,340.83888785193426,10.830175728301262,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 260BW,Centrosolar America,Multi-c-Si,0,260.0,237.0,1.6111239999999998,1.634,0.986,60.0,9.07,38.16,8.5,30.59,0.004997570000000001,-0.1194408,45.3,1.5345734265982283,9.080857725594049,1.4205146179282485e-10,0.35790779080293456,298.9782661378998,8.09119257455904,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 260SW,Centrosolar America,Multi-c-Si,0,260.0,237.0,1.6111239999999998,1.634,0.986,60.0,9.07,38.16,8.5,30.59,0.004997570000000001,-0.1194408,45.3,1.5345734265982283,9.080857725594049,1.4205146179282485e-10,0.35790779080293456,298.9782661378998,8.09119257455904,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6 260xx,Centrosolar America,Mono-c-Si,0,260.0,236.2,1.6335,1.65,0.99,60.0,9.04,37.8,8.49,30.8,0.004972,-0.11529,46.9,1.502108520067177,9.049074850125645,1.0507815509339126e-10,0.29426580971359534,293.13576567267404,8.315700294150739,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6S 260xx,Centrosolar America,Mono-c-Si,0,260.0,236.2,1.6335,1.65,0.99,60.0,9.04,37.8,8.49,30.8,0.004972,-0.11529,46.9,1.502108520067177,9.049074850125645,1.0507815509339126e-10,0.29426580971359534,293.13576567267404,8.315700294150739,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6 260xx,Centrosolar America,Multi-c-Si,0,260.0,234.3,1.6335,1.65,0.99,60.0,8.99,37.9,8.46,30.9,0.0045849,-0.115595,48.2,1.5121157106927055,8.997192454538078,1.1583005200021701e-10,0.2924643559826352,365.55736924923804,9.259325648336667,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6S 260xx,Centrosolar America,Multi-c-Si,0,260.0,234.3,1.6335,1.65,0.99,60.0,8.99,37.9,8.46,30.9,0.0045849,-0.115595,48.2,1.5121157106927055,8.997192454538078,1.1583005200021701e-10,0.2924643559826352,365.55736924923804,9.259325648336667,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP60 265-C1,Centrosolar America,Multi-c-Si,0,265.0,239.5,1.6268799999999999,1.64,0.992,60.0,9.2,38.3,8.47,30.89,0.0057224,-0.1351607,45.4,1.637445926504635,9.223450160011637,6.188292763357471e-10,0.3089860244311678,121.22184983387447,7.719146924023103,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 265,Centrosolar America,Mono-c-Si,0,265.0,240.7,1.6397760000000001,1.653,0.992,60.0,8.9,38.5,8.3,32.0,0.0066741100000000005,-0.12474,45.6,1.6301339298072552,8.908888524931962,4.820492175904912e-10,0.19542020772435142,195.6725133000472,15.19074806111262,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 265,Centrosolar America,Multi-c-Si,0,265.0,239.1,1.6397760000000001,1.653,0.992,60.0,8.73,38.4,8.23,32.2,0.006462819,-0.13017600000000001,46.5,1.6432916932710466,8.732792396813355,6.148055014121576e-10,0.15580600219410184,487.1036875562398,12.387318652883184,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 265BB,Centrosolar America,Mono-c-Si,0,265.0,241.1,1.6111239999999998,1.634,0.986,60.0,9.1,38.29,8.65,30.64,0.0056238,-0.1160187,45.4,1.5509726027027766,9.100003142967013,1.727001854583526e-10,0.34525598246567124,999999.9301711441,13.306259160809626,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM60 265SW,Centrosolar America,Mono-c-Si,0,265.0,241.9,1.6111239999999998,1.634,0.986,60.0,9.1,38.29,8.65,30.64,0.0044681,-0.1137213,45.2,1.5183791361449546,9.100003245692259,1.0165768445563556e-10,0.3565858706515448,999999.9292797324,10.926133385097845,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP6 265BW,Centrosolar America,Multi-c-Si,0,265.0,236.1,1.622912,1.636,0.992,60.0,9.24,37.77,8.61,30.78,0.0036036,-0.12841800000000003,47.1,1.614520831814823,9.251858730924543,6.274037812565626e-10,0.26050740265953887,202.98030175848697,12.154155267906823,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP6 265SW,Centrosolar America,Multi-c-Si,0,265.0,236.1,1.622912,1.636,0.992,60.0,9.24,37.77,8.61,30.78,0.0036036,-0.12841800000000003,47.1,1.614520831814823,9.251858730924543,6.274037812565626e-10,0.26050740265953887,202.98030175848697,12.154155267906823,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 265BW,Centrosolar America,Multi-c-Si,0,265.0,241.7,1.6111239999999998,1.634,0.986,60.0,9.24,38.29,8.62,30.74,0.005091240000000001,-0.1198477,45.3,1.5446727283233364,9.255486837787197,1.556468661077318e-10,0.34630718452130127,206.61923930768444,8.745358377853027,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 265SW,Centrosolar America,Multi-c-Si,0,265.0,241.7,1.6111239999999998,1.634,0.986,60.0,9.24,38.29,8.62,30.74,0.005091240000000001,-0.1198477,45.3,1.5446727283233364,9.255486837787197,1.556468661077318e-10,0.34630718452130127,206.61923930768444,8.745358377853027,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6 265xx,Centrosolar America,Mono-c-Si,0,265.0,240.8,1.6335,1.65,0.99,60.0,9.16,38.0,8.6,31.0,0.005038,-0.1159,46.9,1.5112907374049973,9.169362431505036,1.0862967908018735e-10,0.28689835197998725,280.6951427111089,8.492704074060944,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6S 265xx,Centrosolar America,Mono-c-Si,0,265.0,240.8,1.6335,1.65,0.99,60.0,9.16,38.0,8.6,31.0,0.005038,-0.1159,46.9,1.5112907374049973,9.169362431505036,1.0862967908018735e-10,0.28689835197998725,280.6951427111089,8.492704074060944,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6 265xx,Centrosolar America,Multi-c-Si,0,265.0,238.9,1.6335,1.65,0.99,60.0,9.12,38.5,8.55,31.0,0.004651199999999999,-0.117425,48.2,1.5284610230615643,9.131205482228445,1.0342995148866728e-10,0.3459231771138403,281.5425085265218,8.15123128264532,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP6S 265xx,Centrosolar America,Multi-c-Si,0,265.0,238.9,1.6335,1.65,0.99,60.0,9.12,38.5,8.55,31.0,0.004651199999999999,-0.117425,48.2,1.5284610230615643,9.131205482228445,1.0342995148866728e-10,0.3459231771138403,281.5425085265218,8.15123128264532,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 270,Centrosolar America,Mono-c-Si,0,270.0,245.3,1.6397760000000001,1.653,0.992,60.0,8.9,38.8,8.4,32.2,0.0066741100000000005,-0.125712,45.6,1.6308122735547514,8.90303569253132,4.1090274998977403e-10,0.2062874917999665,604.7908922398233,13.662735324919586,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP60 270,Centrosolar America,Multi-c-Si,0,270.0,243.7,1.6397760000000001,1.653,0.992,60.0,8.8,38.6,8.32,32.46,0.00651464,-0.13085400000000003,46.5,1.6519165071498585,8.80165778692079,6.22269193236766e-10,0.14310194706140572,759.625775034384,12.414743097311032,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 270,Centrosolar America,Multi-c-Si,0,270.0,238.6,1.94432,1.96,0.992,72.0,8.09,43.85,7.59,35.55,0.004854,-0.15786,46.7,1.9355899698582588,8.094541819320861,1.1633126705845223e-09,0.3554629217034769,633.1598311234839,12.248972816336597,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 270BB,Centrosolar America,Mono-c-Si,0,270.0,245.8,1.6111239999999998,1.634,0.986,60.0,9.12,38.68,8.76,30.83,0.0056361599999999994,-0.11720040000000001,45.4,1.5719016698649817,9.12026259124612,1.8754045220294368e-10,0.31480284676161596,10933.390334035184,14.04408182573664,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM60 270SW,Centrosolar America,Mono-c-Si,0,270.0,246.5,1.6111239999999998,1.634,0.986,60.0,9.12,38.68,8.76,30.83,0.004477919999999999,-0.1148796,45.2,1.538747593132894,9.12027168783377,1.103666788663274e-10,0.3270692729890361,10979.066951652565,11.644578876205578,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP60 270BW,Centrosolar America,Multi-c-Si,0,270.0,246.4,1.6111239999999998,1.634,0.986,60.0,9.31,38.72,8.72,30.97,0.00512981,-0.1211936,45.3,1.5556008518244169,9.321822526444434,1.4231488960450524e-10,0.36309869130662914,285.9328882651024,7.881062442965126,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 270SW,Centrosolar America,Multi-c-Si,0,270.0,246.4,1.6111239999999998,1.634,0.986,60.0,9.31,38.72,8.72,30.97,0.00512981,-0.1211936,45.3,1.5556008518244169,9.321822526444434,1.4231488960450524e-10,0.36309869130662914,285.9328882651024,7.881062442965126,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6 270xx,Centrosolar America,Mono-c-Si,0,270.0,244.5,1.6335,1.65,0.99,60.0,9.28,38.2,8.71,31.2,0.0038975999999999998,-0.10619600000000003,47.8,1.4958051671313777,9.290432495585588,7.411455283731335e-11,0.2857442080661458,254.17756673402718,15.541805922734452,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6S 270xx,Centrosolar America,Mono-c-Si,0,270.0,244.5,1.6335,1.65,0.99,60.0,9.28,38.2,8.71,31.2,0.0038975999999999998,-0.10619600000000003,47.8,1.4958051671313777,9.290432495585588,7.411455283731335e-11,0.2857442080661458,254.17756673402718,15.541805922734452,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM60 275,Centrosolar America,Mono-c-Si,0,275.0,250.0,1.6397760000000001,1.653,0.992,60.0,9.0,39.1,8.4,32.8,0.0067491,-0.12668400000000002,45.6,1.663554183423682,9.00699861010018,5.462141092194915e-10,0.15431234230911994,198.44100510299563,16.26062281334929,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 275,Centrosolar America,Multi-c-Si,0,275.0,243.2,1.94432,1.96,0.992,72.0,8.2,44.0,7.7,35.7,0.004919999999999999,-0.15839999999999999,46.7,1.942189269203606,8.204001342748503,1.1799647606813317e-09,0.3476395104905964,712.4225472450066,12.252566749087405,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 275BB,Centrosolar America,Mono-c-Si,0,275.0,250.5,1.6111239999999998,1.634,0.986,60.0,9.14,39.08,8.88,30.97,0.005648520000000001,-0.11841239999999999,45.4,1.59236647424272,9.140190183787015,2.005949411966338e-10,0.2733800557269827,13138.363274204448,14.64513482446108,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM60 275BW,Centrosolar America,Mono-c-Si,0,275.0,251.2,1.6111239999999998,1.634,0.986,60.0,9.14,39.08,8.88,30.97,0.0044877400000000005,-0.11606759999999999,45.2,1.5585762266733452,9.140198647760554,1.1782644547019485e-10,0.2869666641788666,13203.683324290316,12.214380653377905,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM60 275SW,Centrosolar America,Mono-c-Si,0,275.0,251.2,1.6111239999999998,1.634,0.986,60.0,9.14,39.08,8.88,30.97,0.0044877400000000005,-0.11606759999999999,45.2,1.5585762266733452,9.140198647760554,1.1782644547019485e-10,0.2869666641788666,13203.683324290316,12.214380653377905,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP60 275BW,Centrosolar America,Multi-c-Si,0,275.0,251.1,1.6111239999999998,1.634,0.986,60.0,9.35,38.92,8.78,31.32,0.00515185,-0.12181960000000001,45.3,1.56692405149284,9.35906119135005,1.509420049200318e-10,0.337918586199003,348.68915157336625,8.349753732058682,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 275SW,Centrosolar America,Multi-c-Si,0,275.0,251.1,1.6111239999999998,1.634,0.986,60.0,9.35,38.92,8.78,31.32,0.00515185,-0.12181960000000001,45.3,1.56692405149284,9.35906119135005,1.509420049200318e-10,0.337918586199003,348.68915157336625,8.349753732058682,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6 275xx,Centrosolar America,Mono-c-Si,0,275.0,249.2,1.6335,1.65,0.99,60.0,9.36,38.4,8.8,31.4,0.0039312,-0.10675200000000001,47.8,1.5033017873819874,9.369061034982794,7.446953519715033e-11,0.2800202604845518,289.2594217685131,15.499446737020428,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6S 275xx,Centrosolar America,Mono-c-Si,0,275.0,249.2,1.6335,1.65,0.99,60.0,9.36,38.4,8.8,31.4,0.0039312,-0.10675200000000001,47.8,1.5033017873819874,9.369061034982794,7.446953519715033e-11,0.2800202604845518,289.2594217685131,15.499446737020428,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 280,Centrosolar America,Multi-c-Si,0,280.0,247.7,1.94432,1.96,0.992,72.0,8.31,44.15,7.81,35.85,0.004986,-0.15894,46.7,1.9488069750423094,8.313475015647777,1.1968641317375317e-09,0.34002862760825364,813.1304300786293,12.257943563914896,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 280BB,Centrosolar America,Mono-c-Si,0,280.0,255.2,1.6111239999999998,1.634,0.986,60.0,9.23,39.26,9.03,31.01,0.005704140000000001,-0.1189578,45.4,1.6026036389411835,9.230161701159304,2.1177833606352666e-10,0.2315160740498033,13215.125357623405,15.05753030079511,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM60 280BW,Centrosolar America,Mono-c-Si,0,280.0,255.9,1.6111239999999998,1.634,0.986,60.0,9.23,39.26,9.03,31.01,0.00453193,-0.11660219999999999,45.2,1.5687748138693285,9.230341992630116,1.2483236711836171e-10,0.24388082487472046,6582.044395446449,12.649864445860452,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM60 280SW,Centrosolar America,Mono-c-Si,0,280.0,255.9,1.6111239999999998,1.634,0.986,60.0,9.23,39.26,9.03,31.01,0.00453193,-0.11660219999999999,45.2,1.5687748138693285,9.230341992630116,1.2483236711836171e-10,0.24388082487472046,6582.044395446449,12.649864445860452,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP60 280BW,Centrosolar America,Multi-c-Si,0,280.0,255.8,1.6111239999999998,1.634,0.986,60.0,9.47,39.16,8.84,31.68,0.005217970000000001,-0.12257079999999998,45.3,1.586088584287475,9.48439643745677,1.7605092778973691e-10,0.31344941611083327,206.18755016289003,9.61449003152215,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP60 280SW,Centrosolar America,Multi-c-Si,0,280.0,255.8,1.6111239999999998,1.634,0.986,60.0,9.47,39.16,8.84,31.68,0.005217970000000001,-0.12257079999999998,45.3,1.586088584287475,9.48439643745677,1.7605092778973691e-10,0.31344941611083327,206.18755016289003,9.61449003152215,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6 280xx,Centrosolar America,Mono-c-Si,0,280.0,253.8,1.6335,1.65,0.99,60.0,9.43,38.7,8.86,31.7,0.0039606,-0.10758600000000001,47.8,1.5169360868372785,9.439514170957628,7.737785001457319e-11,0.27289452647350715,270.4802501517833,15.790423939717005,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6S 280xx,Centrosolar America,Mono-c-Si,0,280.0,253.8,1.6335,1.65,0.99,60.0,9.43,38.7,8.86,31.7,0.0039606,-0.10758600000000001,47.8,1.5169360868372785,9.439514170957628,7.737785001457319e-11,0.27289452647350715,270.4802501517833,15.790423939717005,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 285,Centrosolar America,Mono-c-Si,0,285.0,258.2,1.94432,1.96,0.992,72.0,8.6,44.1,8.0,35.7,0.00644914,-0.142884,45.6,1.8416558502136393,8.614234850810233,3.3546875933375367e-10,0.3716181656235093,224.51352801382865,12.162554023860027,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 285,Centrosolar America,Multi-c-Si,0,285.0,252.3,1.94432,1.96,0.992,72.0,8.41,44.32,7.91,36.02,0.005046,-0.159552,46.7,1.9565271090259568,8.413011296119583,1.2152811612855127e-09,0.332592402181589,928.8710167156813,12.285753894065127,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 285BB,Centrosolar America,Mono-c-Si,0,285.0,259.9,1.6111239999999998,1.634,0.986,60.0,9.46,39.18,8.95,31.85,0.0058462800000000014,-0.11871539999999998,45.4,1.598485654757871,9.46191081532495,2.1372889883442978e-10,0.289976834113937,1435.607905213507,14.92213569443275,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 285BW,Centrosolar America,Mono-c-Si,0,285.0,260.6,1.6111239999999998,1.634,0.986,60.0,9.46,39.18,8.95,31.85,0.004644860000000001,-0.11636459999999998,45.2,1.5661537382175192,9.462778871447195,1.2871362237429537e-10,0.2975363340535246,1012.8911744633473,12.71557651144978,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 285SW,Centrosolar America,Mono-c-Si,0,285.0,260.6,1.6111239999999998,1.634,0.986,60.0,9.46,39.18,8.95,31.85,0.004644860000000001,-0.11636459999999998,45.2,1.5661537382175192,9.462778871447195,1.2871362237429537e-10,0.2975363340535246,1012.8911744633473,12.71557651144978,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6 285xx,Centrosolar America,Mono-c-Si,0,285.0,258.5,1.6335,1.65,0.99,60.0,9.47,39.1,8.91,32.0,0.003977400000000001,-0.10869800000000002,47.8,1.5308457904176798,9.478515110289342,7.558006166292067e-11,0.27824726456799576,309.4500967453311,15.525558191122022,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM6S 285xx,Centrosolar America,Mono-c-Si,0,285.0,258.5,1.6335,1.65,0.99,60.0,9.47,39.1,8.91,32.0,0.003977400000000001,-0.10869800000000002,47.8,1.5308457904176798,9.478515110289342,7.558006166292067e-11,0.27824726456799576,309.4500967453311,15.525558191122022,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 290,Centrosolar America,Mono-c-Si,0,290.0,262.8,1.94432,1.96,0.992,72.0,8.6,44.4,8.0,36.3,0.00644914,-0.143856,45.6,1.8647841867656856,8.612731480518297,3.839491331546145e-10,0.32146430555301553,217.14625469754083,13.401066976631972,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 290,Centrosolar America,Multi-c-Si,0,290.0,256.9,1.94432,1.96,0.992,72.0,8.52,44.46,8.02,36.16,0.005111999999999999,-0.160056,46.7,1.9626749205862477,8.522511456538709,1.2318099115641654e-09,0.3255776184408686,1104.5086588852405,12.287762129269284,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 290BW,Centrosolar America,Mono-c-Si,0,290.0,265.3,1.6111239999999998,1.634,0.986,60.0,9.59,39.68,9.03,32.12,0.00470869,-0.11784959999999998,45.2,1.5862462524886565,9.59703583124919,1.3002922452148232e-10,0.3147375308085123,428.99454697988904,12.701794776152907,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM60 290SW,Centrosolar America,Mono-c-Si,0,290.0,265.3,1.6111239999999998,1.634,0.986,60.0,9.59,39.68,9.03,32.12,0.00470869,-0.11784959999999998,45.2,1.5862462524886565,9.59703583124919,1.3002922452148232e-10,0.3147375308085123,428.99454697988904,12.701794776152907,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7 290xx,Centrosolar America,Multi-c-Si,0,290.0,262.0,1.9503,1.97,0.99,72.0,8.52,44.9,8.03,36.3,0.004686,-0.13919,47.5,1.7823457690324123,8.525741698440541,9.692158960663073e-11,0.4102644904498189,608.7839434961681,6.353457458895959,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 290xx,Centrosolar America,Multi-c-Si,0,290.0,262.0,1.9503,1.97,0.99,72.0,8.52,44.9,8.03,36.3,0.004686,-0.13919,47.5,1.7823457690324123,8.525741698440541,9.692158960663073e-11,0.4102644904498189,608.7839434961681,6.353457458895959,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 295,Centrosolar America,Mono-c-Si,0,295.0,267.5,1.94432,1.96,0.992,72.0,8.7,44.7,8.1,36.5,0.0065241299999999995,-0.144828,45.6,1.8751740831566663,8.712491849477914,3.7810833750870327e-10,0.3266364772158893,227.48734375455703,13.150458490208049,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 295,Centrosolar America,Multi-c-Si,0,295.0,261.4,1.94432,1.96,0.992,72.0,8.58,44.68,8.1,36.38,0.005148,-0.16084800000000002,46.7,1.970566791482875,8.5806135469093,1.218870969161092e-09,0.319337266706757,4465.722350835824,12.11708076540837,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7 295xx,Centrosolar America,Multi-c-Si,0,295.0,266.6,1.9503,1.97,0.99,72.0,8.62,45.1,8.12,36.5,0.0047409999999999996,-0.13981,47.5,1.7917915498684869,8.626248935825584,1.0008443957474211e-10,0.40178219021211836,554.232417178624,6.531309494131744,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 295xx,Centrosolar America,Multi-c-Si,0,295.0,266.6,1.9503,1.97,0.99,72.0,8.62,45.1,8.12,36.5,0.0047409999999999996,-0.13981,47.5,1.7917915498684869,8.626248935825584,1.0008443957474211e-10,0.40178219021211836,554.232417178624,6.531309494131744,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP72 300-C1,Centrosolar America,Multi-c-Si,0,300.0,271.7,1.9403519999999999,1.956,0.992,72.0,8.79,45.3,8.12,36.5,0.0036390599999999995,-0.16230989999999998,45.4,1.8705193817800607,8.81197908106969,2.5901912699451343e-10,0.40370288872777765,161.45118249622368,-0.5181697745610534,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 300,Centrosolar America,Mono-c-Si,0,300.0,272.1,1.94432,1.96,0.992,72.0,8.7,45.0,8.1,37.1,0.0065241299999999995,-0.1458,45.6,1.8982240800401302,8.71093493347107,4.307501320966823e-10,0.2771867338251107,220.53401915289814,14.357197059027934,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 300,Centrosolar America,Multi-c-Si,0,300.0,266.0,1.94432,1.96,0.992,72.0,8.63,44.82,8.21,36.52,0.005178,-0.161352,46.7,1.9830087862760277,8.630002426821527,1.3184905662450375e-09,0.2808413941696599,999999.9745812472,12.779468886072612,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America TP7 300xx,Centrosolar America,Multi-c-Si,0,300.0,271.2,1.9503,1.97,0.99,72.0,8.72,45.3,8.21,36.7,0.004796000000000001,-0.14043,47.5,1.8012331359119773,8.726740260408851,1.0330917820372663e-10,0.3934882544062157,509.0630727974395,6.707126120057541,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 300xx,Centrosolar America,Multi-c-Si,0,300.0,271.2,1.9503,1.97,0.99,72.0,8.72,45.3,8.21,36.7,0.004796000000000001,-0.14043,47.5,1.8012331359119773,8.726740260408851,1.0330917820372663e-10,0.3934882544062157,509.0630727974395,6.707126120057541,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP72 305-C1,Centrosolar America,Multi-c-Si,0,305.0,276.3,1.9403519999999999,1.956,0.992,72.0,9.05,45.6,8.16,37.4,0.0037467000000000004,-0.1633848,45.4,1.9297341787353623,9.083540177145206,4.652240388130213e-10,0.2966549685907954,80.04512219998612,4.133622161881785,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 305,Centrosolar America,Mono-c-Si,0,305.0,276.8,1.94432,1.96,0.992,72.0,8.8,45.4,8.2,37.2,0.006599120000000001,-0.147096,45.6,1.9074651675672125,8.811544444096878,3.969428338439765e-10,0.3096451312280449,236.03366516251896,13.490613378121346,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 305,Centrosolar America,Multi-c-Si,0,305.0,270.6,1.94432,1.96,0.992,72.0,8.66,44.96,8.27,36.85,0.005195999999999999,-0.161856,46.7,1.9986960673258722,8.660002005983205,1.4730128111957795e-09,0.23134433184302872,999999.7262457703,13.76975579200101,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP72 305BW,Centrosolar America,Multi-c-Si,0,305.0,272.9,1.9403519999999999,1.956,0.992,72.0,8.78,45.12,8.21,37.18,0.0035998,-0.15611519999999998,47.7,1.8763301715257108,8.789093546344478,3.106704552560767e-10,0.28459220008303143,274.7794600728615,4.535568000237109,-0.446,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 305SW,Centrosolar America,Multi-c-Si,0,305.0,277.9,1.9226999999999999,1.95,0.986,72.0,9.04,45.18,8.42,36.23,0.00498104,-0.1414134,45.3,1.8229424892409694,9.056827523271323,1.5266726484345102e-10,0.42344860342795204,227.48300006144615,8.773110015491492,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7 305xx,Centrosolar America,Multi-c-Si,0,305.0,275.9,1.9503,1.97,0.99,72.0,8.82,45.5,8.3,36.9,0.004851,-0.14105,47.5,1.8106706700715645,8.827215874148205,1.065961496322655e-10,0.3853764887331061,471.0476984534904,6.880950278158755,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 305xx,Centrosolar America,Multi-c-Si,0,305.0,275.9,1.9503,1.97,0.99,72.0,8.82,45.5,8.3,36.9,0.004851,-0.14105,47.5,1.8106706700715645,8.827215874148205,1.065961496322655e-10,0.3853764887331061,471.0476984534904,6.880950278158755,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP72 310-C1,Centrosolar America,Multi-c-Si,0,310.0,280.0,1.9403519999999999,1.956,0.992,72.0,9.08,45.8,8.22,37.7,0.00564776,-0.16162819999999997,45.4,2.002040143432612,9.106611535989034,9.976648291774827e-10,0.26183822594124917,89.34062636589721,12.162196794937042,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 310,Centrosolar America,Mono-c-Si,0,310.0,281.4,1.94432,1.96,0.992,72.0,8.8,45.7,8.2,37.9,0.006599120000000001,-0.148068,45.6,1.9333973124194306,8.809576011540477,4.671003801546245e-10,0.2464940080479665,226.5188888387166,15.004154462177734,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 310,Centrosolar America,Multi-c-Si,0,310.0,279.6,1.94432,1.96,0.992,72.0,8.7,45.18,8.31,37.3,0.006440609999999999,-0.1531602,46.5,1.9166898568777233,8.70000202009113,5.039366015774673e-10,0.2320861371462793,999999.8267059064,10.591371401801801,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP72 310BW,Centrosolar America,Multi-c-Si,0,310.0,282.6,1.9226999999999999,1.95,0.986,72.0,9.08,45.65,8.49,36.54,0.005003080000000001,-0.1428845,45.3,1.8363771612061115,9.093229743227171,1.4300420575006596e-10,0.4352197476552703,298.70538842522274,8.147644018873955,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 310SW,Centrosolar America,Multi-c-Si,0,310.0,282.6,1.9226999999999999,1.95,0.986,72.0,9.08,45.65,8.49,36.54,0.005003080000000001,-0.1428845,45.3,1.8363771612061115,9.093229743227171,1.4300420575006596e-10,0.4352197476552703,298.70538842522274,8.147644018873955,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7 310xx,Centrosolar America,Multi-c-Si,0,310.0,280.5,1.9503,1.97,0.99,72.0,8.9,45.7,8.39,37.1,0.004895000000000001,-0.14167000000000002,47.5,1.8180371357678788,8.90579542550601,1.0689563100799035e-10,0.3783850549090727,581.0836645649881,6.821075892360862,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 310xx,Centrosolar America,Multi-c-Si,0,310.0,280.5,1.9503,1.97,0.99,72.0,8.9,45.7,8.39,37.1,0.004895000000000001,-0.14167000000000002,47.5,1.8180371357678788,8.90579542550601,1.0689563100799035e-10,0.3783850549090727,581.0836645649881,6.821075892360862,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP72 315-C1,Centrosolar America,Multi-c-Si,0,315.0,284.7,1.9403519999999999,1.956,0.992,72.0,9.17,45.9,8.31,37.9,0.00570374,-0.1619811,45.4,2.0090143509586116,9.19467527883562,1.0387992692334815e-09,0.2432725167277765,90.4066438722033,12.439225535941267,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 315,Centrosolar America,Mono-c-Si,0,315.0,286.1,1.94432,1.96,0.992,72.0,8.9,46.0,8.3,38.0,0.0066741100000000005,-0.14904,45.6,1.9408653436277987,8.909905318397183,4.439129932656708e-10,0.26660805970794504,239.54928965137273,14.420370698450357,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 315,Centrosolar America,Multi-c-Si,0,315.0,284.2,1.94432,1.96,0.992,72.0,8.72,45.32,8.38,37.58,0.006455416000000001,-0.15363480000000002,46.5,1.9331034745642663,8.720125777384238,5.736704714282562e-10,0.17316717422808328,12005.543790136877,11.741318174052711,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP72 315BW,Centrosolar America,Multi-c-Si,0,315.0,287.3,1.9226999999999999,1.95,0.986,72.0,9.12,45.75,8.56,36.81,0.00502512,-0.1431975,45.3,1.8421642432492413,9.129288288197126,1.4767360707537051e-10,0.40809684284552655,400.7028212622924,8.377788900528556,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 315SW,Centrosolar America,Multi-c-Si,0,315.0,287.3,1.9226999999999999,1.95,0.986,72.0,9.12,45.75,8.56,36.81,0.00502512,-0.1431975,45.3,1.8421642432492413,9.129288288197126,1.4767360707537051e-10,0.40809684284552655,400.7028212622924,8.377788900528556,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7 315SW,Centrosolar America,Mono-c-Si,0,315.0,286.4,1.9503,1.97,0.99,72.0,9.05,45.5,8.49,37.1,0.0036200000000000004,-0.13194999999999998,46.5,1.7923756798946726,9.060383017367604,8.420420476449862e-11,0.3545354398606424,309.0186303853445,12.126714230843708,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7S 315SW,Centrosolar America,Mono-c-Si,0,315.0,286.4,1.9503,1.97,0.99,72.0,9.05,45.5,8.49,37.1,0.0036200000000000004,-0.13194999999999998,46.5,1.7923756798946726,9.060383017367604,8.420420476449862e-11,0.3545354398606424,309.0186303853445,12.126714230843708,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7 315xx,Centrosolar America,Multi-c-Si,0,315.0,285.2,1.9503,1.97,0.99,72.0,8.98,45.9,8.48,37.3,0.004939000000000001,-0.14229,47.5,1.8254218107986957,8.984416193886771,1.0721692999704301e-10,0.37153488918066185,755.4884011834652,6.763701391897214,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 315xx,Centrosolar America,Multi-c-Si,0,315.0,285.2,1.9503,1.97,0.99,72.0,8.98,45.9,8.48,37.3,0.004939000000000001,-0.14229,47.5,1.8254218107986957,8.984416193886771,1.0721692999704301e-10,0.37153488918066185,755.4884011834652,6.763701391897214,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America CP72 320-C1,Centrosolar America,Multi-c-Si,0,320.0,289.3,1.9403519999999999,1.956,0.992,72.0,9.2,46.2,8.33,38.4,0.0057224,-0.1630398,45.4,2.0314144841711967,9.221580891648692,1.1546733871672618e-09,0.20778742355271246,88.58042047716114,13.38681739054855,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 320,Centrosolar America,Mono-c-Si,0,320.0,290.8,1.94432,1.96,0.992,72.0,8.9,46.3,8.3,38.6,0.0066741100000000005,-0.150012,45.6,1.9637983907594179,8.908357779811437,5.020292257865514e-10,0.21846433187258998,232.63747012731127,15.572367491814127,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 320,Centrosolar America,Multi-c-Si,0,320.0,288.8,1.94432,1.96,0.992,72.0,8.76,45.5,8.42,38.0,0.0064850279999999995,-0.15424500000000002,46.5,1.9469197918211354,8.760001562228103,6.207706692755007e-10,0.13945148693373277,780374.6766010969,12.416482601461444,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM72 320BW,Centrosolar America,Mono-c-Si,0,320.0,292.1,1.9226999999999999,1.95,0.986,72.0,9.08,46.31,8.65,37.0,0.00445828,-0.1375407,45.2,1.8369396715554385,9.080003892136936,1.0217447284496802e-10,0.42856693607994256,999999.6623078544,10.991131127414906,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM72 320SW,Centrosolar America,Mono-c-Si,0,320.0,292.1,1.9226999999999999,1.95,0.986,72.0,9.08,46.31,8.65,37.0,0.00445828,-0.1375407,45.2,1.8369396715554385,9.080003892136936,1.0217447284496802e-10,0.42856693607994256,999999.6623078544,10.991131127414906,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP72 320BW,Centrosolar America,Multi-c-Si,0,320.0,291.9,1.9226999999999999,1.95,0.986,72.0,9.24,45.94,8.62,37.13,0.005091240000000001,-0.14379219999999998,45.3,1.860305592462448,9.254708371282295,1.7077762443256198e-10,0.38160581121597426,239.73000540284048,9.564912317795025,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 320SW,Centrosolar America,Multi-c-Si,0,320.0,291.9,1.9226999999999999,1.95,0.986,72.0,9.24,45.94,8.62,37.13,0.005091240000000001,-0.14379219999999998,45.3,1.860305592462448,9.254708371282295,1.7077762443256198e-10,0.38160581121597426,239.73000540284048,9.564912317795025,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7 320SW,Centrosolar America,Mono-c-Si,0,320.0,291.0,1.9503,1.97,0.99,72.0,9.15,45.6,8.58,37.3,0.0036600000000000005,-0.13224,46.5,1.7998138572837066,9.160548008488687,8.936342238765934e-11,0.33530325286309426,290.8629514218359,12.568123863064834,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7S 320SW,Centrosolar America,Mono-c-Si,0,320.0,291.0,1.9503,1.97,0.99,72.0,9.15,45.6,8.58,37.3,0.0036600000000000005,-0.13224,46.5,1.7998138572837066,9.160548008488687,8.936342238765934e-11,0.33530325286309426,290.8629514218359,12.568123863064834,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7 320xx,Centrosolar America,Multi-c-Si,0,320.0,289.8,1.9503,1.97,0.99,72.0,9.06,46.1,8.57,37.5,0.0049830000000000004,-0.14291,47.5,1.8328240301612218,9.063077254072928,1.0755915720751131e-10,0.3648218137316227,1074.1023519344078,6.708722512301083,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TP7S 320xx,Centrosolar America,Multi-c-Si,0,320.0,289.8,1.9503,1.97,0.99,72.0,9.06,46.1,8.57,37.5,0.0049830000000000004,-0.14291,47.5,1.8328240301612218,9.063077254072928,1.0755915720751131e-10,0.3648218137316227,1074.1023519344078,6.708722512301083,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 325,Centrosolar America,Mono-c-Si,0,325.0,295.4,1.94432,1.96,0.992,72.0,9.0,46.6,8.4,38.7,0.0067491,-0.150984,45.6,1.9712841042568943,9.008732864500507,4.77491516326465e-10,0.23865405694253775,245.9544338594871,14.994305075421789,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 325,Centrosolar America,Multi-c-Si,0,325.0,293.5,1.94432,1.96,0.992,72.0,8.78,45.65,8.48,38.32,0.0064998339999999995,-0.15475350000000002,46.5,1.9635355660933154,8.780058400283744,7.021831823267926e-10,0.08020739424628558,12058.581117101043,13.527991481205763,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM72 325BW,Centrosolar America,Mono-c-Si,0,325.0,296.8,1.9226999999999999,1.95,0.986,72.0,9.11,46.54,8.76,37.11,0.0044730099999999995,-0.13822379999999998,45.2,1.8527537273252972,9.1102996753005,1.1223826402898566e-10,0.38532839276968717,11713.841659801066,11.805965061959487,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM72 325SW,Centrosolar America,Mono-c-Si,0,325.0,296.8,1.9226999999999999,1.95,0.986,72.0,9.11,46.54,8.76,37.11,0.0044730099999999995,-0.13822379999999998,45.2,1.8527537273252972,9.1102996753005,1.1223826402898566e-10,0.38532839276968717,11713.841659801066,11.805965061959487,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EP72 325BW,Centrosolar America,Multi-c-Si,0,325.0,296.6,1.9226999999999999,1.95,0.986,72.0,9.28,46.31,8.72,37.28,0.0051132799999999996,-0.1449503,45.3,1.8641889568216912,9.28835329199161,1.4940956907757846e-10,0.40335905237801345,448.1074576007093,8.323936902723649,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 325SW,Centrosolar America,Multi-c-Si,0,325.0,296.6,1.9226999999999999,1.95,0.986,72.0,9.28,46.31,8.72,37.28,0.0051132799999999996,-0.1449503,45.3,1.8641889568216912,9.28835329199161,1.4940956907757846e-10,0.40335905237801345,448.1074576007093,8.323936902723649,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7 325SW,Centrosolar America,Mono-c-Si,0,325.0,295.7,1.9503,1.97,0.99,72.0,9.25,45.8,8.67,37.5,0.0037,-0.13282,46.5,1.8090585581752916,9.260894971903458,9.200828036250834e-11,0.32820302077719105,278.64944767084995,12.736215836532686,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7S 325SW,Centrosolar America,Mono-c-Si,0,325.0,295.7,1.9503,1.97,0.99,72.0,9.25,45.8,8.67,37.5,0.0037,-0.13282,46.5,1.8090585581752916,9.260894971903458,9.200828036250834e-11,0.32820302077719105,278.64944767084995,12.736215836532686,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 330,Centrosolar America,Mono-c-Si,0,330.0,300.1,1.94432,1.96,0.992,72.0,9.0,46.9,8.4,39.3,0.0067491,-0.151956,45.6,1.9941630633492413,9.007197553457527,5.382802922308501e-10,0.19113440831331865,238.9992462213748,16.12211800895707,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DP72 330,Centrosolar America,Multi-c-Si,0,330.0,298.2,1.94432,1.96,0.992,72.0,8.82,45.8,8.54,38.62,0.0065294459999999995,-0.155262,46.5,1.9760160336568393,8.820000374552084,7.575490247351829e-10,0.042448125646069555,999999.9676426401,14.186934869326276,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Centrosolar America EM72 330BW,Centrosolar America,Mono-c-Si,0,330.0,301.5,1.9226999999999999,1.95,0.986,72.0,9.29,46.64,8.79,37.55,0.004561389999999999,-0.1385208,45.2,1.854526995404895,9.292130707418725,1.1084151996095616e-10,0.40914594095061596,1783.899138645266,11.524853111625543,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 330SW,Centrosolar America,Mono-c-Si,0,330.0,301.5,1.9226999999999999,1.95,0.986,72.0,9.29,46.64,8.79,37.55,0.004561389999999999,-0.1385208,45.2,1.854526995404895,9.292130707418725,1.1084151996095616e-10,0.40914594095061596,1783.899138645266,11.524853111625543,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 330BW,Centrosolar America,Multi-c-Si,0,330.0,301.3,1.9226999999999999,1.95,0.986,72.0,9.35,46.65,8.78,37.58,0.00515185,-0.1460145,45.3,1.879236148875064,9.359031535801751,1.531365241096485e-10,0.3997559733741521,413.8519552888802,8.476367540552259,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 330SW,Centrosolar America,Multi-c-Si,0,330.0,301.3,1.9226999999999999,1.95,0.986,72.0,9.35,46.65,8.78,37.58,0.00515185,-0.1460145,45.3,1.879236148875064,9.359031535801751,1.531365241096485e-10,0.3997559733741521,413.8519552888802,8.476367540552259,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7 330SW,Centrosolar America,Mono-c-Si,0,330.0,300.4,1.9503,1.97,0.99,72.0,9.32,46.1,8.73,37.8,0.0037280000000000004,-0.13369,46.5,1.822926575541307,9.331297363561063,9.52525094150654e-11,0.32055558500844633,264.44914689704257,12.985748690552272,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7S 330SW,Centrosolar America,Mono-c-Si,0,330.0,300.4,1.9503,1.97,0.99,72.0,9.32,46.1,8.73,37.8,0.0037280000000000004,-0.13369,46.5,1.822926575541307,9.331297363561063,9.52525094150654e-11,0.32055558500844633,264.44914689704257,12.985748690552272,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America DM72 335,Centrosolar America,Mono-c-Si,0,335.0,304.8,1.94432,1.96,0.992,72.0,9.1,47.2,8.5,39.5,0.00682409,-0.152928,45.6,2.004562542188957,9.107190751722202,5.299885807387185e-10,0.1975795083752177,250.03974041062892,15.868322640073682,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 335BW,Centrosolar America,Mono-c-Si,0,335.0,306.2,1.9226999999999999,1.95,0.986,72.0,9.33,46.75,8.83,37.94,0.00458103,-0.1388475,45.2,1.8667341309405134,9.332375059346226,1.2363153708213965e-10,0.36842483769075296,1447.2921123236022,12.473611912108678,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 335SW,Centrosolar America,Mono-c-Si,0,335.0,306.2,1.9226999999999999,1.95,0.986,72.0,9.33,46.75,8.83,37.94,0.00458103,-0.1388475,45.2,1.8667341309405134,9.332375059346226,1.2363153708213965e-10,0.36842483769075296,1447.2921123236022,12.473611912108678,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 335BW,Centrosolar America,Multi-c-Si,0,335.0,306.0,1.9226999999999999,1.95,0.986,72.0,9.47,46.83,8.84,37.9,0.005217970000000001,-0.1465779,45.3,1.8971690076214458,9.484347827000532,1.7701734397863063e-10,0.3728414201278564,246.0866363501428,9.663066143754932,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EP72 335SW,Centrosolar America,Multi-c-Si,0,335.0,306.0,1.9226999999999999,1.95,0.986,72.0,9.47,46.83,8.84,37.9,0.005217970000000001,-0.1465779,45.3,1.8971690076214458,9.484347827000532,1.7701734397863063e-10,0.3728414201278564,246.0866363501428,9.663066143754932,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7 335SW,Centrosolar America,Mono-c-Si,0,335.0,305.1,1.9503,1.97,0.99,72.0,9.37,46.4,8.79,38.1,0.0037479999999999996,-0.13455999999999999,46.5,1.8347958863360154,9.38007890643092,9.592786580940124e-11,0.3138999806796481,291.8216326551463,12.995530073722701,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America TM7S 335SW,Centrosolar America,Mono-c-Si,0,335.0,305.1,1.9503,1.97,0.99,72.0,9.37,46.4,8.79,38.1,0.0037479999999999996,-0.13455999999999999,46.5,1.8347958863360154,9.38007890643092,9.592786580940124e-11,0.3138999806796481,291.8216326551463,12.995530073722701,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 340BW,Centrosolar America,Mono-c-Si,0,340.0,310.9,1.9226999999999999,1.95,0.986,72.0,9.41,46.91,8.91,38.17,0.00462031,-0.1393227,45.2,1.8753433612395454,9.412106523718492,1.2847959531082036e-10,0.3534256140129159,1578.7792844675862,12.744150108509919,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 340SW,Centrosolar America,Mono-c-Si,0,340.0,310.9,1.9226999999999999,1.95,0.986,72.0,9.41,46.91,8.91,38.17,0.00462031,-0.1393227,45.2,1.8753433612395454,9.412106523718492,1.2847959531082036e-10,0.3534256140129159,1578.7792844675862,12.744150108509919,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 345BW,Centrosolar America,Mono-c-Si,0,345.0,315.6,1.9226999999999999,1.95,0.986,72.0,9.48,47.13,8.99,38.38,0.0046546800000000004,-0.13997610000000002,45.2,1.8835293361086398,9.480872315807641,1.2861319780129548e-10,0.34850908786859136,3787.4664914270234,12.680248121507743,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 345SW,Centrosolar America,Mono-c-Si,0,345.0,315.6,1.9226999999999999,1.95,0.986,72.0,9.48,47.13,8.99,38.38,0.0046546800000000004,-0.13997610000000002,45.2,1.8835293361086398,9.480872315807641,1.2861319780129548e-10,0.34850908786859136,3787.4664914270234,12.680248121507743,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 350BW,Centrosolar America,Mono-c-Si,0,350.0,320.3,1.9226999999999999,1.95,0.986,72.0,9.59,47.64,9.09,38.51,0.00470869,-0.1414908,45.2,1.896769971503945,9.59076429133492,1.184404368434309e-10,0.38489027526672265,4829.443829909236,11.829823670111146,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Centrosolar America EM72 350SW,Centrosolar America,Mono-c-Si,0,350.0,320.3,1.9226999999999999,1.95,0.986,72.0,9.59,47.64,9.09,38.51,0.00470869,-0.1414908,45.2,1.896769971503945,9.59076429133492,1.184404368434309e-10,0.38489027526672265,4829.443829909236,11.829823670111146,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed Apollo II - 67,CertainTeed,Mono-c-Si,0,67.0,60.9,0.42,,,14.0,9.34,9.35,8.9,7.56,0.0044832,-0.025712500000000003,48.52,0.35203252152193604,9.340000749957268,2.7256181742398865e-11,0.08027348161008477,999999.2160347458,7.572526056034287,-0.373,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 67,CertainTeed,Mono-c-Si,0,67.0,61.1,0.42,,,14.0,9.34,9.35,8.9,7.56,0.0044832,-0.025712500000000003,47.74,0.35203252152193604,9.340000749957268,2.7256181742398865e-11,0.08027348161008477,999999.2160347458,7.572526056034287,-0.373,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Solstice Shingle 68W-01,CertainTeed,Mono-c-Si,0,68.0,60.8,0.53,,,14.0,9.3,9.37,8.83,7.7,0.0034410000000000005,-0.024643099999999998,53.61,0.3391371346305482,9.30419486878522,9.263471319283599e-12,0.07047660825732945,156.24624097781137,3.2876055394832684,-0.342,Y,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed Apollo II - 70x,CertainTeed,Mono-c-Si,0,70.0,59.7,0.53,,,14.0,9.417,9.571,9.028,7.767,0.00433182,-0.026128830000000002,61.75,0.360220975009177,9.41700100993253,2.7214073282970756e-11,0.07267129526035675,677717.4867610362,8.306278739628487,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 70x,CertainTeed,Mono-c-Si,0,70.0,61.0,0.54,,,14.0,9.417,9.571,9.028,7.767,0.00433182,-0.026128830000000002,57.03,0.360220975009177,9.41700100993253,2.7214073282970756e-11,0.07267129526035675,677717.4867610362,8.306278739628487,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Solstice Shingle 70W-01,CertainTeed,Mono-c-Si,0,70.0,62.6,0.53,,,14.0,9.44,9.51,8.96,7.82,0.0034928,-0.025011300000000004,53.61,0.3443642860692408,9.44452805013361,9.52016433282402e-12,0.06983351264693886,145.5876918197486,3.3933867643187954,-0.342,Y,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed Apollo II - 71x,CertainTeed,Mono-c-Si,0,71.0,60.6,0.53,,,14.0,9.455,9.641,9.085,7.82,0.0043493,-0.026319930000000002,61.75,0.3631355185676879,9.455000982151475,2.7889392436267616e-11,0.07090161585540745,682659.6729911863,8.485797289012176,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 71x,CertainTeed,Mono-c-Si,0,71.0,61.9,0.54,,,14.0,9.455,9.641,9.085,7.82,0.0043493,-0.026319930000000002,57.03,0.3631355185676879,9.455000982151475,2.7889392436267616e-11,0.07090161585540745,682659.6729911863,8.485797289012176,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo II - 72x,CertainTeed,Mono-c-Si,0,72.0,61.5,0.53,,,14.0,9.493,9.71,9.137,7.886,0.00436678,-0.026508300000000002,61.75,0.36620455829234666,9.493000943951209,2.8972270675513803e-11,0.06803111074197524,684266.25187684,8.785088250604623,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 72x,CertainTeed,Mono-c-Si,0,72.0,62.8,0.54,,,14.0,9.493,9.71,9.137,7.886,0.00436678,-0.026508300000000002,57.03,0.36620455829234666,9.493000943951209,2.8972270675513803e-11,0.06803111074197524,684266.25187684,8.785088250604623,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Solstice Shingle 72W-01,CertainTeed,Mono-c-Si,0,72.0,64.4,0.53,,,14.0,9.57,9.65,9.08,7.93,0.0035409,-0.025379500000000003,53.61,0.349382266710063,9.574902484083458,9.60846118546287e-12,0.07054542663957743,137.70972617728043,3.3574215296737306,-0.342,Y,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed Apollo II - 73x,CertainTeed,Mono-c-Si,0,73.0,62.4,0.53,,,14.0,9.531,9.766,9.192,7.939,0.00438426,-0.02666118,61.75,0.36878891119214885,9.531000819802419,3.0093104075707794e-11,0.06490392078102031,754666.7255644591,9.084097427303174,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 73x,CertainTeed,Mono-c-Si,0,73.0,63.7,0.54,,,14.0,9.531,9.766,9.192,7.939,0.00438426,-0.02666118,57.03,0.36878891119214885,9.531000819802419,3.0093104075707794e-11,0.06490392078102031,754666.7255644591,9.084097427303174,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo II - 74x,CertainTeed,Mono-c-Si,0,74.0,63.3,0.53,,,14.0,9.579,9.863,9.268,8.005,0.004406340000000001,-0.02692599,61.75,0.3727160227866504,9.57900079263662,3.0817632563543016e-11,0.06263383834668425,757020.9806014663,9.249662011579883,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 74x,CertainTeed,Mono-c-Si,0,74.0,64.6,0.54,,,14.0,9.579,9.863,9.268,8.005,0.004406340000000001,-0.02692599,57.03,0.3727160227866504,9.57900079263662,3.0817632563543016e-11,0.06263383834668425,757020.9806014663,9.249662011579883,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo II - 75x,CertainTeed,Mono-c-Si,0,75.0,64.2,0.53,,,14.0,9.616,9.919,9.328,8.058,0.0044233599999999994,-0.02707887,61.75,0.3754516489769892,9.616078432180974,3.231285286423077e-11,0.05814856167408505,7129.182712256057,9.635039266979275,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed Apollo Tile II - 75x,CertainTeed,Mono-c-Si,0,75.0,65.5,0.54,,,14.0,9.616,9.919,9.328,8.058,0.0044233599999999994,-0.02707887,57.03,0.3754516489769892,9.616078432180974,3.231285286423077e-11,0.05814856167408505,7129.182712256057,9.635039266979275,-0.371,Y,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT280M10-02,CertainTeed,Mono-c-Si,0,280.0,256.7,1.6268799999999999,1.64,0.992,60.0,9.34,39.1,8.88,31.53,0.0037359999999999997,-0.1173,44.58,1.5424590337478223,9.34000307795881,9.148636900621157e-11,0.32948322310498646,999999.8580004738,8.764250947263442,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT280M11-02,CertainTeed,Mono-c-Si,0,280.0,256.7,1.6268799999999999,1.64,0.992,60.0,9.34,39.1,8.88,31.53,0.0037359999999999997,-0.1173,44.58,1.5424590337478223,9.34000307795881,9.148636900621157e-11,0.32948322310498646,999999.8580004738,8.764250947263442,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT285M10-01,CertainTeed,Multi-c-Si,0,285.0,258.9,1.63672,1.64,0.998,60.0,9.5,38.7,8.9,31.8,0.00331505483549352,-0.11331439588688948,46.04,1.5614075575216992,9.51021373418357,1.6081692750065394e-10,0.24809504099872293,230.75821016718825,16.589417394296046,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT285M10-02,CertainTeed,Mono-c-Si,0,285.0,261.4,1.6268799999999999,1.64,0.992,60.0,9.48,39.43,8.97,31.76,0.0037920000000000007,-0.11828999999999999,44.58,1.5551320082061078,9.482588698803452,9.205381342631495e-11,0.3400815565507167,1245.4032702136212,8.698895849907192,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT285M11-01,CertainTeed,Multi-c-Si,0,285.0,258.0,1.63672,1.64,0.998,60.0,9.5,38.7,8.9,31.8,0.004617373319544984,-0.11689588688946015,46.48,1.5908649409194988,9.509335387647688,2.5472352904101093e-10,0.24109010270169082,245.34130345171275,17.089999299930376,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT290M10-01,CertainTeed,Multi-c-Si,0,290.0,263.5,1.63672,1.64,0.998,60.0,9.7,38.8,9.1,32.0,0.0033848454636091724,-0.11360719794344473,46.04,1.567482667738401,9.70902211584343,1.6979980174979244e-10,0.22862335121693608,245.8011647888037,16.899349687281372,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT290M10-02,CertainTeed,Mono-c-Si,0,290.0,266.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.77,9.06,32.0,0.003848,-0.11931000000000001,44.58,1.5712623604212808,9.627340405234149,9.707870375162008e-11,0.342447118018945,448.7956020514584,9.054593276658517,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT290M11-01,CertainTeed,Multi-c-Si,0,290.0,262.6,1.63672,1.64,0.998,60.0,9.7,38.8,9.1,32.0,0.004714581178903826,-0.11719794344473006,46.48,1.597085106634213,9.708189701983683,2.6891507415975373e-10,0.22172166301176519,262.61032896831836,17.401248023924875,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT290M11-02,CertainTeed,Mono-c-Si,0,290.0,266.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.77,9.06,32.0,0.003848,-0.11931000000000001,44.58,1.5712623604212808,9.627340405234149,9.707870375162008e-11,0.342447118018945,448.7956020514584,9.054593276658517,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT295M10-01,CertainTeed,Multi-c-Si,0,295.0,268.3,1.63672,1.64,0.998,60.0,9.8,39.0,9.2,32.1,0.003402777777777778,-0.1141928020565553,46.04,1.5710680949111657,9.80891714467489,1.5997337012086322e-10,0.23628780651036804,259.6818350666213,16.243419901817216,-0.43042886317222595,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT295M10-02,CertainTeed,Mono-c-Si,0,295.0,270.4,1.6268799999999999,1.64,0.992,60.0,9.77,40.11,9.15,32.24,0.0041034,-0.1131102,46.67,1.530069215334997,9.785671253536337,3.960261725042655e-11,0.35782532897941155,223.0806574585144,7.8432896838665584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT295M11-01,CertainTeed,Multi-c-Si,0,295.0,267.3,1.63672,1.64,0.998,60.0,9.8,39.0,9.2,32.1,0.004763185108583248,-0.11780205655526992,46.48,1.6029490127504338,9.808005587627829,2.623748663936504e-10,0.22894592681529496,280.26303772707035,17.067910042882907,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT295M11-02,CertainTeed,Mono-c-Si,0,295.0,270.4,1.6268799999999999,1.64,0.992,60.0,9.77,40.11,9.15,32.24,0.0041034,-0.1131102,46.67,1.530069215334997,9.785671253536337,3.960261725042655e-11,0.35782532897941155,223.0806574585144,7.8432896838665584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT300M10-01,CertainTeed,Multi-c-Si,0,300.0,272.9,1.63672,1.64,0.998,60.0,9.9,39.1,9.3,32.3,0.003454636091724826,-0.11448560411311057,46.04,1.5799173704903122,9.908122491593039,1.7440353053472263e-10,0.21929159753292604,267.2809023328239,16.953708630424796,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT300M10-02,CertainTeed,Mono-c-Si,0,300.0,275.1,1.6268799999999999,1.64,0.992,60.0,9.91,40.45,9.24,32.48,0.0041622000000000004,-0.11406899999999999,46.67,1.5455351056335254,9.930945213767378,4.169229983689515e-11,0.3601251937774448,170.3893201772202,8.18489238767737,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT300M10-03,CertainTeed,Mono-c-Si,0,300.0,277.2,1.617,,,60.0,9.75,40.3,9.24,32.5,0.0043875,-0.112437,45.6,1.5133344781620164,9.75356476439876,2.6427281399560664e-11,0.3503432142814507,958.2250543403749,5.441561537611864,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT300M11-01,CertainTeed,Multi-c-Si,0,300.0,270.3,1.63672,1.64,0.998,60.0,9.9,39.1,9.3,32.3,0.004366153846153846,-0.12848556962025318,46.59,1.6501587357401475,9.90628604577147,5.012466454445252e-10,0.2033299431135747,320.2278336616182,13.266090694828222,-0.461090031045188,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT300M11-02,CertainTeed,Mono-c-Si,0,300.0,274.0,1.575,1.64,0.992,60.0,9.91,40.45,9.24,32.48,0.0041622000000000004,-0.11366450000000002,48.62,1.5251264323230047,9.931883472624044,2.93537341826874e-11,0.3648298583528548,165.21436147729784,5.543961155141448,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT300M11-03,CertainTeed,Mono-c-Si,0,300.0,276.3,1.606,,,60.0,9.75,40.3,9.24,32.5,0.0041925,-0.11364599999999998,46.06,1.521121385307385,9.753306035912917,3.029514470924624e-11,0.348546600707314,1027.9167196224753,5.495861605142172,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT305M10-02,CertainTeed,Mono-c-Si,0,305.0,279.8,1.6268799999999999,1.64,0.992,60.0,10.061831783469275,40.791992844343525,9.319077416024621,32.72856167881353,0.004225969349057096,-0.11503341982104874,46.67,1.5630767855278895,10.09084521074077,4.5268101294795724e-11,0.36118505919228383,125.25867191411358,8.798278225543383,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT305M11-02,CertainTeed,Mono-c-Si,0,305.0,278.7,1.575,1.64,0.992,60.0,10.06,40.79,9.3,32.7,0.004225200000000001,-0.11461990000000001,48.62,1.5430593189869422,10.092453707740116,3.221327411217557e-11,0.3694255591077215,114.51453225997304,6.2435622389989005,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT310HC11-04,CertainTeed,Mono-c-Si,0,310.0,285.7,1.609,,,60.0,9.95,39.58,9.51,32.58,0.004278499999999999,-0.10884500000000001,47.62,1.4639770783443065,9.95000254712591,1.804101038889657e-11,0.25598392835984224,999999.6256983201,3.5717134691723182,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT310M11-02,CertainTeed,Mono-c-Si,0,310.0,283.4,1.575,,,60.0,10.21,41.14,9.4,33.0,0.004288200000000001,-0.11560340000000001,48.62,1.559969738755325,10.247572800675101,3.4619749719756123e-11,0.36488578248463377,99.15374436300529,6.752111633629163,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT315HC11-04,CertainTeed,Mono-c-Si,0,315.0,290.4,1.609,,,60.0,10.04,39.74,9.6,32.79,0.004317199999999999,-0.10928500000000002,47.62,1.4716632972211485,10.04000245484567,1.8805233004951392e-11,0.24449836686950066,999999.5738148569,3.8446194014380026,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT315M11-02,CertainTeed,Mono-c-Si,0,315.0,288.1,1.575,,,60.0,10.37,41.49,9.5,33.2,0.004355400000000001,-0.11658690000000002,48.62,1.5750906376748204,10.415100227004615,3.606409496669009e-11,0.3724113411383971,85.62940586223951,6.988640761519833,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT320HC11-04,CertainTeed,Mono-c-Si,0,320.0,295.2,1.609,,,60.0,10.13,39.92,9.69,33.01,0.0043559,-0.10978,47.62,1.4799631550097843,10.130002371083295,1.9548024613401773e-11,0.23405750200003683,999998.7272768797,4.095690099067443,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT320P00-01,CertainTeed,Multi-c-Si,0,320.0,293.6,1.81,,,72.0,9.0,45.7,8.8,36.4,0.0036,-0.13253,45.5,1.7728288718384,9.000002609429352,5.741072444290723e-11,0.2899006010472286,999949.6707301033,8.7183505979829,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT325HC11-04,CertainTeed,Mono-c-Si,0,325.0,294.9,1.68,,,60.0,10.43,40.1,9.93,32.71,0.00715498,-0.1267962,48.5,1.6097192896213282,10.43000262637483,1.5830572378100448e-10,0.2517464026198033,999999.6596255436,6.515080459614108,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT325P00-01,CertainTeed,Multi-c-Si,0,325.0,298.3,1.81,,,72.0,9.1,45.9,8.8,36.6,0.00364,-0.13311,45.5,1.7728392805169186,9.100003361749975,5.186369541932766e-11,0.36936667641423204,999934.6146524,7.7366900364615026,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT330HC11-04,CertainTeed,Mono-c-Si,0,330.0,299.6,1.68,,,60.0,10.51,40.27,10.02,32.91,0.007209859999999999,-0.12733374,48.5,1.6189752000308448,10.510002514504084,1.6560162612623525e-10,0.23918586024488556,999993.2000934965,6.83771483995845,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT335HC11-04,CertainTeed,Mono-c-Si,0,335.0,304.3,1.68,,,60.0,10.6,40.44,10.11,33.11,0.0072716,-0.12787127999999998,48.5,1.6275112607486355,10.600002439999043,1.7142008607842163e-10,0.23012807060468438,999991.4920755792,7.062533301352397,-0.4034,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CT350M00-01,CertainTeed,Mono-c-Si,0,350.0,321.8,1.81,,,72.0,9.6,47.1,9.0,38.7,0.003744,-0.13659,45.6,1.8420646006907293,9.611302069110318,7.41589534182572e-11,0.31283648744185416,265.723942202757,10.482402849400929,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT350M10-01,CertainTeed,Mono-c-Si,0,350.0,321.8,1.81,,,72.0,9.6,47.1,9.0,38.7,0.003744,-0.13659,45.6,1.8420646006907293,9.611302069110318,7.41589534182572e-11,0.31283648744185416,265.723942202757,10.482402849400929,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT355M00-01,CertainTeed,Mono-c-Si,0,355.0,326.6,1.81,,,72.0,9.7,47.3,9.1,38.9,0.0037829999999999995,-0.13717,45.6,1.850154170207565,9.710785107315774,7.526306403672043e-11,0.3064315050783543,275.6009367986762,10.51913615988894,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT355M10-01,CertainTeed,Mono-c-Si,0,355.0,326.6,1.81,,,72.0,9.7,47.3,9.1,38.9,0.0037829999999999995,-0.13717,45.6,1.850154170207565,9.710785107315774,7.526306403672043e-11,0.3064315050783543,275.6009367986762,10.51913615988894,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT355M10-02,CertainTeed,Mono-c-Si,0,355.0,325.5,1.9403519999999999,1.956,0.992,72.0,9.898520572643996,47.465658561456,9.208248308672879,38.552392170576006,0.004157378640510479,-0.13385315714330592,46.67,1.826812329847677,9.919665167918762,5.012715363806859e-11,0.3675994143669868,172.08607556276885,9.82881105488008,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT355M10-03,CertainTeed,Mono-c-Si,0,355.0,324.9,1.923,,,72.0,9.64,47.0,9.04,39.3,0.0041452,-0.13536,47.21,1.8314159594968222,9.649183698736731,6.764135171615037e-11,0.22899824091973198,240.37625185280848,10.355485055678994,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT355M11-02,CertainTeed,Mono-c-Si,0,355.0,325.5,1.9403519999999999,1.956,0.992,72.0,9.898520572643996,47.465658561456,9.208248308672879,38.552392170576006,0.004157378640510479,-0.13385315714330592,46.67,1.826812329847677,9.919665167918762,5.012715363806859e-11,0.3675994143669868,172.08607556276885,9.82881105488008,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT355M11-03,CertainTeed,Mono-c-Si,0,355.0,327.5,1.923,,,72.0,9.64,47.0,9.04,39.3,0.004241600000000001,-0.13207000000000002,45.73,1.8128192263600378,9.649603609638218,5.195982254125106e-11,0.23350668279676454,234.39149813330047,10.732987791273786,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360HC11-06,CertainTeed,Mono-c-Si,0,360.0,328.3,1.76,,,60.0,11.24,40.6,10.66,33.8,0.0012364,-0.11286800000000002,48.4,1.5297588326994198,11.244497187031143,3.322645598421154e-11,0.19535503055283715,488.2586781783822,7.020335156831882,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360M00-01,CertainTeed,Mono-c-Si,0,360.0,331.3,1.81,,,72.0,9.8,47.4,9.2,39.1,0.0038220000000000003,-0.13745999999999997,45.6,1.856439870082651,9.810036377683845,7.860399530977065e-11,0.28912996061577056,282.3203533375756,10.812927542052613,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360M10-01,CertainTeed,Mono-c-Si,0,360.0,331.3,1.81,,,72.0,9.8,47.4,9.2,39.1,0.0038220000000000003,-0.13745999999999997,45.6,1.856439870082651,9.810036377683845,7.860399530977065e-11,0.28912996061577056,282.3203533375756,10.812927542052613,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360M10-02,CertainTeed,Mono-c-Si,0,360.0,330.2,1.9403519999999999,1.956,0.992,72.0,9.98760725779779,47.56058987857892,9.319303340142914,38.62949695491716,0.004194795048275073,-0.13412086345759253,46.67,1.8277007997887391,10.006039406257855,4.8803593152253205e-11,0.36511524095647263,197.84062209165737,9.500579182678859,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360M10-03,CertainTeed,Mono-c-Si,0,360.0,329.6,1.923,,,72.0,9.67,47.4,9.07,39.7,0.0041581,-0.136512,47.21,1.8484372081522218,9.678826284260772,6.922265877101152e-11,0.22190199331260468,243.11389128163452,10.533185495315118,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360M11-02,CertainTeed,Mono-c-Si,0,360.0,328.8,1.882,1.956,0.992,72.0,9.99,47.56,9.32,38.63,0.0041958,-0.13364360000000003,48.62,1.8036305723781967,10.009441176051851,3.447512993991632e-11,0.3704825947861728,190.37537417757187,6.856742419730365,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT360M11-03,CertainTeed,Mono-c-Si,0,360.0,332.3,1.923,,,72.0,9.67,47.4,9.07,39.7,0.0042548,-0.133194,45.73,1.8296518164945417,9.679237580461502,5.317352938161744e-11,0.22644631420156652,237.0464750728218,10.911293125743,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT365HC11-06,CertainTeed,Mono-c-Si,0,365.0,333.1,1.76,,,60.0,11.36,40.7,10.75,33.96,0.0012495999999999998,-0.11314600000000002,48.4,1.53698109898777,11.366070029668611,3.554484573457519e-11,0.1853470095164951,346.87508616007545,7.521101039668826,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT365M10-02,CertainTeed,Mono-c-Si,0,365.0,335.4,1.882,1.956,0.992,72.0,10.08,47.66,9.43,38.71,0.0039312,-0.1339246,47.39,1.7936160831506751,10.09728881046109,2.8479617913240054e-11,0.3707027926310941,216.13309957713656,5.174721104806659,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT365M10-03,CertainTeed,Mono-c-Si,0,365.0,334.3,1.923,,,72.0,9.71,47.8,9.11,40.1,0.0041753,-0.13766399999999998,47.21,1.865388594912611,9.718450125096135,7.0825364089417e-11,0.21464874461800543,246.65187980060668,10.699801027105279,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT365M11-02,CertainTeed,Mono-c-Si,0,365.0,333.5,1.882,1.956,0.992,72.0,10.08,47.66,9.43,38.71,0.0042336000000000006,-0.1339246,48.62,1.8049387164518182,10.096899649920633,3.365589767816617e-11,0.36811444193339554,219.56630297289456,6.561015885838217,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT370HC11-06,CertainTeed,Mono-c-Si,0,370.0,337.8,1.76,,,60.0,11.51,40.8,10.87,34.06,0.0012660999999999998,-0.113424,48.4,1.526952603652229,11.510002378467917,2.8626911627074894e-11,0.18438762495126593,892330.1189362379,5.517750364910998,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT370M00-04,CertainTeed,Mono-c-Si,0,370.0,345.0,1.882,,,72.0,9.9,47.9,9.3,39.8,0.004158,-0.13220400000000002,43.54,1.8345637722929855,9.90991458429495,4.4538227074894936e-11,0.26465534877878183,264.26604608797646,11.136532049422263,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT370M10-02,CertainTeed,Mono-c-Si,0,370.0,340.1,1.882,,,72.0,10.17,47.75,9.5,38.8,0.0039663,-0.13417750000000003,47.39,1.7987277802421402,10.188862038425242,2.9422045338241666e-11,0.3660520774774011,197.3673037987075,5.382196622523516,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT370M10-03,CertainTeed,Mono-c-Si,0,370.0,339.0,1.923,,,72.0,9.74,48.2,9.14,40.5,0.0041881999999999996,-0.138816,47.21,1.8824010836183966,9.748107365663346,7.241986093090247e-11,0.20766073014210804,249.47874906937946,10.870673298327674,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT370M11-02,CertainTeed,Mono-c-Si,0,370.0,338.2,1.882,,,72.0,10.17,47.75,9.5,38.8,0.0042714,-0.13417750000000003,48.62,1.8100895873648957,10.188460571978997,3.476751069949615e-11,0.3634721787091547,200.2382216743355,6.77057366277475,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT375M00-04,CertainTeed,Mono-c-Si,0,375.0,349.7,1.882,,,72.0,9.9,48.2,9.3,40.2,0.004158,-0.133032,43.54,1.8496914590983569,9.909372969061897,4.686757637010874e-11,0.2475765645257595,261.4975048433962,11.595834361801515,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT375M10-02,CertainTeed,Mono-c-Si,0,375.0,344.9,1.882,,,72.0,10.26,47.85,9.7,38.9,0.0040014,-0.13445850000000004,47.39,1.7925081723007423,10.266907447572356,2.5965936758491462e-11,0.3612989543428261,536.6566056384526,4.200632028323106,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT375M11-02,CertainTeed,Mono-c-Si,0,375.0,342.9,1.882,,,72.0,10.26,47.85,9.7,38.9,0.0043092,-0.13445850000000004,48.62,1.8037916890048462,10.266586709827966,3.069463970109143e-11,0.35879538210396045,558.8891618760177,5.577533744061101,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT380M10-02,CertainTeed,Mono-c-Si,0,380.0,349.6,1.882,,,72.0,10.35,47.94,9.8,38.9,0.0040365,-0.1347114,47.39,1.7928416986195361,10.355385074770142,2.5085211814497516e-11,0.36745240373716803,706.235785195993,3.8301425836033354,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT390HC00-04,CertainTeed,Mono-c-Si,0,390.0,364.4,1.95,,,72.0,10.48,48.18,9.66,40.37,0.0045064,-0.12864060000000002,44.52,1.8139982869523306,10.501883332837041,2.9319886703737135e-11,0.22157789766380556,106.11438362194517,10.665600970926176,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT390HC11-04,CertainTeed,Mono-c-Si,0,390.0,354.1,1.95,,,72.0,10.48,48.18,9.66,40.37,0.00512472,-0.15330876,48.1,1.975559024498917,10.49647724398948,2.583168562396994e-10,0.1847768401061288,117.52337563776784,10.43383278744158,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT395HC00-04,CertainTeed,Mono-c-Si,0,395.0,369.1,1.95,,,72.0,10.56,48.37,9.74,40.55,0.0045408,-0.1291479,44.52,1.8210374093223074,10.581441774202847,2.951548623613439e-11,0.21841563060895752,107.5689467439508,10.654512002932163,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT395HC11-04,CertainTeed,Mono-c-Si,0,395.0,358.8,1.95,,,72.0,10.56,48.37,9.74,40.55,0.00516384,-0.15391333999999998,48.1,1.9832147141677134,10.576082735563439,2.600434259913678e-10,0.18176950568388922,119.3507176128507,10.423173207177559,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10395HC11-06,CertainTeed,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT400HC00-04,CertainTeed,Mono-c-Si,0,400.0,373.9,1.95,,,72.0,10.64,48.55,9.81,40.77,0.0045752,-0.1296285,44.52,1.8298075916043999,10.661053996285682,3.059339222846159e-11,0.20938480169216456,105.81621976042658,10.910559949223902,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT400HC11-04,CertainTeed,Mono-c-Si,0,400.0,363.5,1.95,,,72.0,10.64,48.55,9.81,40.77,0.00520296,-0.1544861,48.1,1.992956486855234,10.655682825128517,2.695265701671743e-10,0.17273419819669664,117.19137991563038,10.677337404872281,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10400HC11-06,CertainTeed,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10400HC11-08,CertainTeed,Mono-c-Si,1,400.0,376.5,1.93,,,54.0,13.74,37.08,13.08,30.59,0.0064578,-0.09455399999999999,43.6,1.339491148343632,13.743358095132036,1.3010174317910424e-11,0.1789693953956059,732.2721502895592,5.9613139833370115,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10400HC11-09,CertainTeed,Mono-c-Si,0,400.0,375.6,1.94,,,108.0,13.54,37.2,12.8,31.3,0.0008124,-0.09151200000000001,42.6,1.3536729776749064,13.549088642757702,1.552003852275411e-11,0.12872433877196998,191.76983861634346,12.18254436811979,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT405HC00-04,CertainTeed,Mono-c-Si,0,405.0,378.7,1.95,,,72.0,10.71,48.73,9.89,40.95,0.0046053000000000005,-0.1301091,44.52,1.835783534055856,10.729995388396565,3.049157202025956e-11,0.2057151716588234,110.18588149261802,10.815460227538239,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT405HC11-04,CertainTeed,Mono-c-Si,0,405.0,368.2,1.95,,,72.0,10.71,48.73,9.89,40.95,0.005237190000000001,-0.15505885999999997,48.1,1.9993894028510393,10.724784012970082,2.686411314573337e-10,0.16925412053575262,122.6129660704559,10.583724072939454,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10405HC11-06,CertainTeed,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10410HC11-06,CertainTeed,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC425HC12-08,CertainTeed,Mono-c-Si,1,425.0,402.8,1.95,,,54.0,14.05,38.3,13.23,32.2,0.006884500000000001,-0.08770700000000001,43.5,1.3515387448935687,14.064517819158244,6.792911468023796e-12,0.13717338162298207,132.7531356573545,11.806866153067405,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT430HC11-06,CertainTeed,Mono-c-Si,0,430.0,394.8,2.1,,,72.0,11.19,49.5,10.6,40.6,0.0074973,-0.14948999999999998,47.4,1.9347618178173802,11.190008842705762,8.661610083067529e-11,0.2884621127764893,365049.70328300906,5.677366322402263,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC430HC12-08,CertainTeed,Mono-c-Si,1,430.0,407.6,1.95,,,54.0,14.13,38.4,13.28,32.5,0.0069237000000000005,-0.087936,43.5,1.3605506460870964,14.14429589091297,7.636481749474214e-12,0.11811811600070628,116.74746206756764,12.845732078085785,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT435HC11-06,CertainTeed,Mono-c-Si,0,435.0,399.5,2.1,,,72.0,11.26,49.7,10.67,40.8,0.007544200000000001,-0.150094,47.4,1.9498805152993317,11.263238714278703,9.551895014834608e-11,0.28271663484182086,982.917732445926,6.476542394837407,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10435HC11-06,CertainTeed,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,40.95,12.96,33.63,0.007395470000000001,-0.11138400000000001,43.6,1.5290244116054013,13.676148139014527,3.1761523952668715e-11,0.20361617907753368,452.7278143631316,6.721421091413095,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC435HC12-08,CertainTeed,Mono-c-Si,1,435.0,412.5,1.95,,,54.0,14.22,38.5,13.32,32.8,0.006967800000000001,-0.08816500000000001,43.5,1.370514591952998,14.23437706582374,8.732280216170539e-12,0.09898062338916118,97.89928513682227,14.052795944076568,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CT440HC11-06,CertainTeed,Mono-c-Si,0,440.0,404.2,2.1,,,72.0,11.33,49.9,10.74,41.0,0.0075911,-0.150698,47.4,1.9583168009806837,11.332974923606098,9.68833686996204e-11,0.2782467487559686,1059.7031929688155,6.544338007914559,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10440HC11-06,CertainTeed,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.02,13.05,33.72,0.007427930000000001,-0.11157440000000003,43.6,1.5305495397668754,13.733250837708983,3.138945279212656e-11,0.20025165287596605,845.7682522336652,6.571426706940132,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTM10440HC11-09,CertainTeed,Mono-c-Si,0,440.0,412.4,2.14,,,108.0,13.72,40.9,12.86,34.2,0.0049392,-0.10552199999999999,43.1,1.5366064622561426,13.735644548749931,3.7002567122343906e-11,0.14975763647651988,131.33492096896083,14.224454297322703,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC440HC12-08,CertainTeed,Mono-c-Si,1,440.0,417.3,1.95,,,54.0,14.3,38.6,13.36,33.0,0.007007000000000001,-0.088394,43.5,1.3780670561223085,14.314517686137044,9.494057576115711e-12,0.08861308508211539,87.28437203850729,14.798261551080351,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CTM10445HC11-06,CertainTeed,Mono-c-Si,0,445.0,417.2,2.16,,,60.0,13.79,41.1,13.16,33.82,0.00746039,-0.11179200000000002,43.6,1.5230357694994607,13.790005128939356,2.629508271735187e-11,0.19826140688761676,533072.2356760007,5.002385774862916,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC445HC12-08,CertainTeed,Mono-c-Si,1,445.0,422.2,1.95,,,54.0,14.38,38.8,13.4,33.2,0.007046200000000001,-0.08885199999999999,43.5,1.3875049533275543,14.395548304378847,9.969346218022199e-12,0.08578763945409389,79.34152988164132,15.218648303624697,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CTM10450HC11-06,CertainTeed,Mono-c-Si,0,450.0,422.0,2.16,,,60.0,13.85,41.18,13.27,33.91,0.0074928500000000006,-0.11200960000000001,43.6,1.5301606964755194,13.850005010708049,2.842005641451503e-11,0.1947939459496308,538440.8843964805,5.629540063448199,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC450HC12-08,CertainTeed,Mono-c-Si,1,450.0,427.0,1.95,,,54.0,14.47,38.8,13.44,33.5,0.007090300000000002,-0.08885199999999999,43.5,1.3957148512398225,14.482247758633171,1.1771314686327126e-11,0.05942984987673846,70.212840910232,16.755184047289575,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +CertainTeed CTM10455HC11-06,CertainTeed,Mono-c-Si,0,455.0,426.8,2.16,,,60.0,13.93,41.33,13.36,34.06,0.007536130000000001,-0.1124176,43.6,1.5413926366914639,14.013466063613366,3.1741411496157716e-11,0.19047938999153652,999999.8801695533,6.4836709139633335,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +CertainTeed CTTC455HC12-08,CertainTeed,Mono-c-Si,1,455.0,431.9,1.95,,,54.0,14.54,39.0,13.48,33.8,0.0071246,-0.08931,43.5,1.4067427139282986,14.550617990514906,1.272741773415895e-11,0.04840519992826255,66.28482164458372,17.466904682880035,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-395M54-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,37.0,12.81,30.8,0.007397999999999999,-0.10064000000000001,43.6,1.401112053396488,13.718401636004915,4.5467711736231086e-11,0.14579716737264542,108.54584935188754,9.914154993638125,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-400M54-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.0,12.9,31.0,0.007446599999999999,-0.10064000000000001,43.6,1.405525586039239,13.806185608837279,4.971883658960144e-11,0.12698888506058306,108.19344250773712,10.654167514200976,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-405M54-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.2,12.98,31.2,0.0074898,-0.10118400000000002,43.6,1.4136049317724912,13.885653601947263,5.047677708958482e-11,0.12409551906465267,109.95583438500063,10.736597514315712,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-410M54-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.3,13.04,31.5,0.007532999999999999,-0.101456,43.6,1.4233184991192205,13.964301567322108,5.652072432988775e-11,0.104494465020068,101.92573757276448,11.710011806016594,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-435M60-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,41.0,12.96,33.6,0.007381800000000001,-0.11152000000000002,43.6,1.529753992196075,13.676110956682624,3.114263089377789e-11,0.21010601205766605,469.99993863841866,6.551713688813641,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.0,13.05,33.7,0.0074142,-0.11152000000000002,43.6,1.5302380974126233,13.733227689903009,3.1630274073642386e-11,0.20038228792807086,852.3894912001904,6.638704358612484,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-445M60-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,445.0,417.1,2.16,,,60.0,13.79,41.1,13.16,33.8,0.007446599999999999,-0.11179200000000002,43.6,1.5331244854823864,13.790002691854419,3.140486476311248e-11,0.19519241000659182,999999.8780740772,6.527530390213811,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-450M60-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,450.0,421.9,2.16,,,60.0,13.85,41.2,13.27,33.9,0.007479,-0.11206400000000001,43.6,1.5398499053856847,13.850002519631197,3.3229866633604754e-11,0.1819104539202851,999985.7845830459,6.978858187866988,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-455M60-HLV,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,455.0,426.7,2.16,,,60.0,13.93,41.3,13.36,34.1,0.007522200000000001,-0.112336,43.6,1.5465595465608057,13.930002353280006,3.518526499040645e-11,0.16892624032954812,999995.1003490807,7.425641680065245,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-535M72-HL/BF-DG,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,535.0,504.0,2.57,,,72.0,13.78,49.4,12.9,41.5,0.0049608,-0.13683800000000002,43.2,1.8071668173209074,13.797193513399424,1.8058151585241188e-11,0.17221405352979038,138.0235446284227,0.33281632904610203,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-540M72-HL/BF-DG,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,540.0,508.8,2.57,,,72.0,13.85,49.5,12.97,41.7,0.004986,-0.13711500000000001,43.2,1.813091333563237,13.86610716871159,1.8783591630388587e-11,0.16147354042417808,138.84554015809388,0.6120094531351281,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-545M72-HL/BF-DG,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,545.0,513.7,2.57,,,72.0,13.92,49.7,13.04,41.8,0.0050111999999999995,-0.137669,43.2,1.8185877664525838,13.936459824231562,1.837726960085145e-11,0.16737621586893997,141.54932026511332,0.3906677437283002,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-550M72-HL/BF-DG,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,550.0,518.5,2.57,,,72.0,13.99,49.8,13.11,42.0,0.0050364,-0.137946,43.2,1.824511061292898,14.00540395111646,1.9109600099699812e-11,0.15677801511280334,142.38713318551947,0.6679011759608745,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou EGing Photovoltaic Technology Co Ltd EG-555M72-HL/BF-DG,Changzhou EGing Photovoltaic Technology Co Ltd,Mono-c-Si,0,555.0,523.3,2.57,,,72.0,14.02,50.0,13.18,42.1,0.005047199999999999,-0.1385,43.2,1.8274322221389896,14.033534243968907,1.8000645872452027e-11,0.16345004417174258,169.31641192156906,0.1496490148557414,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou Nesl Solartech DJ-230P-ST15,Changzhou Nesl Solartech,Multi-c-Si,0,230.0,203.1,1.6335,1.65,0.99,60.0,8.78,37.48,7.81,30.73,0.00469290573372206,-0.13113995726495725,47.3,1.6955026153623163,8.81501587711931,2.0451316610585247e-09,0.22399548327916222,56.16539571476045,20.429248767204257,-0.49253075571177507,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou Nesl Solartech DJ-235P-ST15,Changzhou Nesl Solartech,Multi-c-Si,0,235.0,212.2,1.6335,1.65,0.99,60.0,8.8,36.2,7.91,29.7,0.0072688000000000015,-0.136836,45.7,1.5970958428410236,8.83087263314266,1.1840210900314251e-09,0.2236527754282273,63.750461388645,6.171165301199772,-0.44096,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou Nesl Solartech DJ-240DA/C-ST15,Changzhou Nesl Solartech,Mono-c-Si,0,240.0,216.7,1.6335,1.65,0.99,60.0,8.55,37.57,7.92,30.3,0.006916950000000001,-0.15606578000000002,45.8,1.6201485126020196,8.566197482027636,7.087187716858994e-10,0.3218560626560654,169.89491753657734,-7.273016111737415,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou Nesl Solartech DJ-240P-ST15,Changzhou Nesl Solartech,Multi-c-Si,0,240.0,215.4,1.93743,1.957,0.99,72.0,8.32,39.64,7.18,34.21,0.007463040000000001,-0.15752936,46.5,1.7324544028928435,8.3201988792639,8.52322093629746e-10,0.000999990000834017,41.83400922702497,-1.226765550965332,-0.4352,N,2025.7.3,6/23/2025,2.0,first_pass +Changzhou Nesl Solartech DJ-245DA/C-ST15,Changzhou Nesl Solartech,Mono-c-Si,0,245.0,221.3,1.6335,1.65,0.99,60.0,8.68,37.82,8.03,30.5,0.00702212,-0.15710428,45.8,1.632098964162359,8.697488088888543,7.304167986846849e-10,0.31925198375945896,158.45686469598044,-7.156144353331228,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou Nesl Solartech DJ-250DA/C-ST15,Changzhou Nesl Solartech,Mono-c-Si,0,250.0,226.0,1.6335,1.65,0.99,60.0,8.79,38.07,8.14,30.7,0.0071111099999999995,-0.15814278,45.8,1.6418703523203544,8.806900843403882,7.300219147788808e-10,0.3176816307629478,165.22382970857336,-7.257774890041855,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Changzhou Nesl Solartech DJ-255D/C-ST15,Changzhou Nesl Solartech,Mono-c-Si,0,255.0,230.6,1.6335,1.65,0.99,60.0,8.94,38.19,8.28,30.8,0.00723246,-0.15864125999999998,45.8,1.647029372074083,8.957061881230889,7.424175655788254e-10,0.3128835625315982,163.9432108350511,-7.258700565478079,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-560,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,560.0,526.6,2.56,,,72.0,14.07,50.5,13.25,42.3,0.00599382,-0.118978,45.85,1.7764732148062938,14.085421047785136,6.2254316712364625e-12,0.19451710424261023,177.4753377277313,7.952301134657973,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-565,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,565.0,531.5,2.56,,,72.0,14.15,50.7,13.31,42.5,0.0060279,-0.1194492,45.85,1.785106591393638,14.166376128929516,6.41308444822866e-12,0.1913231533497152,165.3151753674269,8.171143869888175,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-570,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,570.0,536.3,2.56,,,72.0,14.23,50.9,13.37,42.7,0.006061980000000001,-0.11992040000000001,45.85,1.7937434221516768,14.247295322138594,6.605017173725912e-12,0.18815674899082332,154.80894323475397,8.388737232545312,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-575,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,575.0,541.1,2.56,,,72.0,14.31,51.1,13.41,42.9,0.00609606,-0.1203916,45.85,1.803635167654604,14.329497843225914,6.924311238194046e-12,0.1848945030037909,135.69912892913152,8.771903900698998,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-580,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,580.0,545.9,2.56,,,72.0,14.39,51.3,13.47,43.1,0.00613014,-0.1208628,45.85,1.8122838410853672,14.410323687356547,7.128439589746497e-12,0.18177626762842125,128.70501538757838,8.987047598720752,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,585.0,550.8,2.56,,,72.0,14.47,51.5,13.53,43.3,0.006164220000000001,-0.12133400000000001,45.85,1.820935823439995,14.49111477328904,7.337100955312368e-12,0.17868462264164497,122.45296006063752,9.200965624842402,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-590,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,590.0,555.6,2.56,,,72.0,14.55,51.7,13.59,43.5,0.0061983,-0.1218052,45.85,1.8295910048582602,14.5718714091687,7.550349837769617e-12,0.175619237584662,116.8310596646743,9.413657387623902,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-595,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,595.0,560.5,2.56,,,72.0,14.62,51.85,13.67,43.55,0.006228119999999999,-0.12215860000000002,45.85,1.8324293596289336,14.64174659820819,7.31346247120844e-12,0.18174475103671492,122.18500741576398,9.079501988419635,-0.3061,N,2025.7.3,6/23/2025,2.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-600,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,600.0,566.8,2.68,,,66.0,15.83,48.3,14.89,40.3,0.00660111,-0.1197357,45.38,1.6753168535760496,15.85057560412738,4.672461996041785e-12,0.18061040437844467,138.95400849279054,-0.7768939603221036,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-600,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,600.0,565.3,2.56,,,72.0,14.7,52.0,13.73,43.7,0.0062622,-0.12251200000000001,45.85,1.839149310453662,14.722601355968049,7.50589755166553e-12,0.1791892350378664,116.5452976155949,9.268378239039544,-0.3061,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-605,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,605.0,571.6,2.68,,,66.0,15.89,48.5,14.96,40.45,0.006626130000000001,-0.1202315,45.38,1.681217091644361,15.909730171570747,4.612573878967677e-12,0.18199414027228644,146.5718032078122,-0.9173992020747802,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-610,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,610.0,576.4,2.68,,,66.0,15.95,48.7,15.03,40.6,0.006651150000000001,-0.12072730000000001,45.38,1.6871201538917955,15.968867671466084,4.554132416656851e-12,0.1833641257431359,155.0089420377293,-1.056373522780836,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-615,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,615.0,581.3,2.68,,,66.0,16.02,48.9,15.1,40.75,0.006680340000000001,-0.1212231,45.38,1.6935089580893579,16.038736409515092,4.5338101019745166e-12,0.18458425641325335,157.82318313499093,-1.1299079045153266,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-620,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,620.0,586.1,2.68,,,66.0,16.08,49.1,15.16,40.9,0.0067053600000000005,-0.12171890000000002,45.38,1.6999269534329893,16.098632873627228,4.513026958362178e-12,0.1859074107968612,160.4363971751977,-1.1989954745687401,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-625,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,625.0,591.0,2.68,,,66.0,16.14,49.3,15.23,41.05,0.006730380000000001,-0.12221470000000001,45.38,1.7058360093126748,16.15773315999239,4.457412710307741e-12,0.18723981300085737,170.41805205442438,-1.3343399599068066,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-630,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,630.0,595.8,2.68,,,66.0,16.21,49.5,15.3,41.2,0.006759570000000001,-0.1227105,45.38,1.7122271150946138,16.22758129450273,4.4384406100080996e-12,0.1884256702258741,173.72896648440008,-1.4055541164020668,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-635,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,635.0,600.7,2.68,,,66.0,16.27,49.7,15.36,41.35,0.006784590000000001,-0.12320630000000002,45.38,1.7186471600924134,16.287458722658194,4.418996359572937e-12,0.18971616627249993,176.79884647181237,-1.472425048310463,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-640,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,640.0,605.5,2.68,,,66.0,16.33,49.9,15.43,41.5,0.006809609999999999,-0.12370210000000001,45.38,1.7245610613102982,16.346522296825643,4.365949449821301e-12,0.19101261953339424,188.78949065590828,-1.6044117183775615,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE66-18X+(ND)-645,CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI,Mono-c-Si,1,645.0,610.4,2.68,,,66.0,16.4,50.1,15.49,41.65,0.006838799999999999,-0.1241979,45.38,1.7314599143808849,16.417165879442468,4.381826788173511e-12,0.1921506471151664,183.57758060113255,-1.6080929054657347,-0.2942,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chinaland Solar Energy HSE235-60P,Chinaland Solar Energy,Multi-c-Si,0,235.0,207.5,1.6236,1.64,0.99,60.0,8.43,35.6,7.88,29.8,0.0027228900000000004,-0.1299756,48.3,1.527965814985225,8.435982068304655,6.296283697733454e-10,0.15549026186415826,219.1187108437442,5.292115057996328,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE235-60P-B,Chinaland Solar Energy,Multi-c-Si,0,235.0,208.5,1.70952,1.676,1.02,60.0,8.43,35.6,7.88,29.8,0.00237726,-0.127448,48.1,1.4908894616924577,8.436808553210271,3.5228916120297265e-10,0.16547917186592878,204.88780619747493,2.5364968278557516,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE240-60M,Chinaland Solar Energy,Mono-c-Si,0,240.0,216.7,1.6236,1.64,0.99,60.0,8.63,36.2,8.11,29.6,0.0037195300000000004,-0.12282660000000001,45.5,1.4995840706387733,8.636295393631292,2.8016091319414037e-10,0.26504209199138234,363.33131033623846,5.826206537662213,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE240-60M-B,Chinaland Solar Energy,Mono-c-Si,0,240.0,216.4,1.70952,1.676,1.02,60.0,8.63,36.2,8.11,29.6,0.0037195300000000004,-0.12282660000000001,45.5,1.4995840706387733,8.636295393631292,2.8016091319414037e-10,0.26504209199138234,363.33131033623846,5.826206537662213,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE240-60P,Chinaland Solar Energy,Multi-c-Si,0,240.0,212.1,1.6236,1.64,0.99,60.0,8.57,35.7,8.0,30.0,0.0027681100000000003,-0.1303407,48.3,1.536979926665046,8.575938797315922,6.861935940800352e-10,0.13591636937774298,196.13456671672324,5.891335634205718,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE240-60P-B,Chinaland Solar Energy,Multi-c-Si,0,240.0,213.1,1.70952,1.676,1.02,60.0,8.57,35.7,8.0,30.0,0.0024167399999999997,-0.127806,48.1,1.4996054195699835,8.576770915121992,3.8414218360725506e-10,0.1458650109609386,184.62249396003827,3.122646655589715,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE245-60M,Chinaland Solar Energy,Mono-c-Si,0,245.0,221.4,1.6236,1.64,0.99,60.0,8.65,36.8,8.13,30.1,0.0037281500000000004,-0.1248624,45.5,1.5245904310498013,8.656195073973416,2.815239128700134e-10,0.26746979362817774,373.46028460720146,5.847403792487129,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE245-60M-B,Chinaland Solar Energy,Mono-c-Si,0,245.0,221.1,1.70952,1.676,1.02,60.0,8.65,36.8,8.13,30.1,0.0037281500000000004,-0.1248624,45.5,1.5245904310498013,8.656195073973416,2.815239128700134e-10,0.26746979362817774,373.46028460720146,5.847403792487129,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE245-60P,Chinaland Solar Energy,Multi-c-Si,0,245.0,216.6,1.6236,1.64,0.99,60.0,8.63,36.1,8.05,30.4,0.0027874900000000005,-0.1318011,48.3,1.5568118018814838,8.635841471552004,7.176505268002789e-10,0.12693501142210425,187.52967668921548,6.218926867207272,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE245-60P-B,Chinaland Solar Energy,Multi-c-Si,0,245.0,217.7,1.70952,1.676,1.02,60.0,8.63,36.1,8.05,30.4,0.0024336600000000003,-0.12923800000000002,48.1,1.518911584286333,8.636675705751433,4.018715368848699e-10,0.13697751046618198,177.07730678032806,3.4431344105389603,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE250-60M,Chinaland Solar Energy,Mono-c-Si,0,250.0,226.0,1.6236,1.64,0.99,60.0,8.74,37.3,8.21,30.5,0.0037669400000000003,-0.1265589,45.5,1.5455063129345907,8.746658416921345,2.851685769211739e-10,0.26953545483744057,353.79884742956403,5.870815388260835,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE250-60M-B,Chinaland Solar Energy,Mono-c-Si,0,250.0,225.7,1.70952,1.676,1.02,60.0,8.74,37.3,8.21,30.5,0.0037669400000000003,-0.1265589,45.5,1.5455063129345907,8.746658416921345,2.851685769211739e-10,0.26953545483744057,353.79884742956403,5.870815388260835,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE250-60P,Chinaland Solar Energy,Multi-c-Si,0,250.0,221.2,1.6236,1.64,0.99,60.0,8.71,36.3,8.17,30.6,0.0028133300000000006,-0.1325313,48.3,1.5613540276044513,8.714044606325224,6.861678554195823e-10,0.12352768268953652,266.0150854640519,5.735111068863879,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE250-60P-B,Chinaland Solar Energy,Multi-c-Si,0,250.0,222.2,1.70952,1.676,1.02,60.0,8.71,36.3,8.17,30.6,0.0024562200000000003,-0.129954,48.1,1.523409291969223,8.7147374861143,3.8405188223832663e-10,0.1334295573813149,245.31397547313233,2.968832636687998,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE255-60M,Chinaland Solar Energy,Mono-c-Si,0,255.0,230.6,1.6236,1.64,0.99,60.0,8.85,37.4,8.32,30.6,0.0038143499999999998,-0.1268982,45.5,1.5495142056821396,8.856156306689634,2.884046067684108e-10,0.2644084220429461,380.1004466812176,5.857588830833942,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE255-60M-B,Chinaland Solar Energy,Mono-c-Si,0,255.0,230.3,1.70952,1.676,1.02,60.0,8.85,37.4,8.32,30.6,0.0038143499999999998,-0.1268982,45.5,1.5495142056821396,8.856156306689634,2.884046067684108e-10,0.2644084220429461,380.1004466812176,5.857588830833942,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE255-60P,Chinaland Solar Energy,Multi-c-Si,0,255.0,225.8,1.6236,1.64,0.99,60.0,8.8,36.4,8.3,30.7,0.0028424000000000006,-0.1328964,48.3,1.5612070245045035,8.802344087156785,6.530607842855715e-10,0.12192551077601561,457.7239307060697,5.205505497521634,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE255-60P-B,Chinaland Solar Energy,Multi-c-Si,0,255.0,226.8,1.70952,1.676,1.02,60.0,8.8,36.4,8.3,30.7,0.0024816,-0.13031199999999998,48.1,1.5233388504726055,8.8029032062202,3.653315963804121e-10,0.1316446582627343,399.032335577546,2.449866927852507,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE260-60M,Chinaland Solar Energy,Mono-c-Si,0,260.0,235.3,1.6236,1.64,0.99,60.0,8.89,38.0,8.35,31.1,0.00383159,-0.128934,45.5,1.5754020060233085,8.896801192365034,2.939847419000117e-10,0.2660607139771396,347.7743279167948,5.986143739968832,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE260-60M-B,Chinaland Solar Energy,Mono-c-Si,0,260.0,235.0,1.70952,1.676,1.02,60.0,8.89,38.0,8.35,31.1,0.00383159,-0.128934,45.5,1.5754020060233085,8.896801192365034,2.939847419000117e-10,0.2660607139771396,347.7743279167948,5.986143739968832,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE260-60P,Chinaland Solar Energy,Multi-c-Si,0,260.0,230.4,1.6236,1.64,0.99,60.0,8.89,36.7,8.42,30.9,0.0028714700000000005,-0.13399170000000002,48.3,1.5688064093686587,8.891059387212113,6.132063333404688e-10,0.1302123175198069,1092.6960363456603,4.569845225863961,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE260-60P-B,Chinaland Solar Energy,Multi-c-Si,0,260.0,231.4,1.70952,1.676,1.02,60.0,8.89,36.7,8.42,30.9,0.0025069800000000002,-0.131386,48.1,1.5308422523414955,8.891541146843727,3.428384058243885e-10,0.13979714901815946,806.4104594795145,1.8276055225710046,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE265-60M,Chinaland Solar Energy,Mono-c-Si,0,265.0,239.9,1.6236,1.64,0.99,60.0,9.02,38.3,8.48,31.3,0.00388762,-0.1299519,45.5,1.5857316216741497,9.026307679063002,2.8923919585834253e-10,0.2707112032270536,387.11789821993045,5.7195832533545765,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE265-60M-B,Chinaland Solar Energy,Mono-c-Si,0,265.0,239.6,1.70952,1.676,1.02,60.0,9.02,38.3,8.48,31.3,0.00388762,-0.1299519,45.5,1.5857316216741497,9.026307679063002,2.8923919585834253e-10,0.2707112032270536,387.11789821993045,5.7195832533545765,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE265-60P,Chinaland Solar Energy,Multi-c-Si,0,265.0,234.9,1.6236,1.64,0.99,60.0,8.94,37.0,8.54,31.0,0.00288762,-0.13508699999999998,48.3,1.5793211728586705,8.940001145048873,5.981046396593523e-10,0.12801025172149938,999999.9285602303,4.300511130245541,-0.4735,N,2025.7.3,6/23/2025,2.0,first_pass +Chinaland Solar Energy HSE265-60P-B,Chinaland Solar Energy,Multi-c-Si,0,265.0,236.0,1.70952,1.676,1.02,60.0,8.94,37.0,8.54,31.0,0.0025210799999999998,-0.13246,48.1,1.539409614199144,8.940001274641475,3.2582628632432443e-10,0.14253029939524955,999999.9299186592,1.349821109353402,-0.4547,N,2025.7.3,6/23/2025,2.0,first_pass +Chinaland Solar Energy HSE270-60M,Chinaland Solar Energy,Mono-c-Si,0,270.0,244.6,1.6236,1.64,0.99,60.0,9.07,37.8,8.51,31.7,0.00390917,-0.1282554,45.5,1.5901002542415912,9.075335671206822,4.234567344123719e-10,0.1539479435309243,261.6930371715232,8.986687784628735,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE270-60M-B,Chinaland Solar Energy,Mono-c-Si,0,270.0,244.2,1.70952,1.676,1.02,60.0,9.07,37.8,8.51,31.7,0.00390917,-0.1282554,45.5,1.5901002542415912,9.075335671206822,4.234567344123719e-10,0.1539479435309243,261.6930371715232,8.986687784628735,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE270-60P,Chinaland Solar Energy,Multi-c-Si,0,270.0,239.5,1.6236,1.64,0.99,60.0,9.06,37.2,8.65,31.2,0.00292638,-0.1358172,48.3,1.5882514262895788,9.060001135499906,6.096603124105332e-10,0.1252607400466578,999999.9570370807,4.349297346827063,-0.4735,N,2025.7.3,6/23/2025,2.0,first_pass +Chinaland Solar Energy HSE270-60P-B,Chinaland Solar Energy,Multi-c-Si,0,270.0,240.6,1.70952,1.676,1.02,60.0,9.06,37.2,8.65,31.2,0.00255492,-0.13317600000000002,48.1,1.5481654592705159,9.060015136275474,3.3242134268840994e-10,0.1394646014465923,83480.48150572978,1.4045763181677848,-0.4547,N,2025.7.3,6/23/2025,2.0,first_pass +Chinaland Solar Energy HSE275-60M-B,Chinaland Solar Energy,Mono-c-Si,0,275.0,248.9,1.70952,1.676,1.02,60.0,9.21,38.0,8.63,31.9,0.003969510000000001,-0.128934,45.5,1.600618441680199,9.215806451626689,4.42907956458743e-10,0.14771131462182868,234.2947869246468,9.252693520899294,-0.4481,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE290-72P,Chinaland Solar Energy,Multi-c-Si,0,290.0,256.4,1.9304999999999999,1.95,0.99,72.0,8.57,43.2,8.0,36.3,0.0027681100000000003,-0.1577232,48.3,1.8597984457286358,8.575950624591547,6.855438307588271e-10,0.1648411202173255,237.4017321305201,5.88321464352472,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE295-72M,Chinaland Solar Energy,Mono-c-Si,0,295.0,266.0,1.9304999999999999,1.95,0.99,72.0,8.65,44.4,8.13,36.3,0.0048699500000000005,-0.1530468,46.1,1.8565971041670257,8.655826075809685,3.520231896671775e-10,0.32054636900103983,475.9166822999517,5.915571792875906,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE295-72P,Chinaland Solar Energy,Multi-c-Si,0,295.0,261.0,1.9304999999999999,1.95,0.99,72.0,8.64,43.3,8.08,36.5,0.0027907200000000004,-0.1580883,48.3,1.8656512369570595,8.644911044911602,7.058920554340882e-10,0.1476096972133466,259.68973751216305,6.057937745691303,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE300-72M,Chinaland Solar Energy,Mono-c-Si,0,300.0,270.6,1.9304999999999999,1.95,0.99,72.0,8.74,44.6,8.21,36.5,0.0049206200000000005,-0.15373620000000002,46.1,1.8665996289463276,8.746222182146447,3.629536328990558e-10,0.31336400288236893,440.16742903204636,6.091141176072478,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE300-72P,Chinaland Solar Energy,Multi-c-Si,0,300.0,265.5,1.9304999999999999,1.95,0.99,72.0,8.71,43.6,8.17,36.7,0.0028133300000000006,-0.15918359999999998,48.3,1.8737339504273836,8.71422105009072,6.726848315350322e-10,0.1560968869777868,322.10091675282985,5.565430944204214,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE305-72M,Chinaland Solar Energy,Mono-c-Si,0,305.0,275.3,1.9304999999999999,1.95,0.99,72.0,8.79,45.1,8.26,36.9,0.00494877,-0.1554597,46.1,1.8868808337290104,8.796020762600216,3.622300904099841e-10,0.3164381835074473,461.98337008174394,6.023765788588401,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE305-72P,Chinaland Solar Energy,Multi-c-Si,0,305.0,270.1,1.9304999999999999,1.95,0.99,72.0,8.78,43.7,8.27,36.9,0.00283594,-0.15954870000000002,48.3,1.8770225127901408,8.782664252714069,6.727775998716558e-10,0.14013671227209382,461.81828523199505,5.483280122331289,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE310-72M,Chinaland Solar Energy,Mono-c-Si,0,310.0,279.9,1.9304999999999999,1.95,0.99,72.0,8.89,45.4,8.35,37.1,0.00500507,-0.15649380000000002,46.1,1.8985736108582432,8.896473417173842,3.62257254357941e-10,0.3213036901761885,441.24922705185827,5.928816906315651,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE310-72P,Chinaland Solar Energy,Multi-c-Si,0,310.0,274.7,1.9304999999999999,1.95,0.99,72.0,8.86,44.0,8.36,37.1,0.00286178,-0.16064399999999998,48.3,1.8864438603882152,8.862247227514104,6.519460900492419e-10,0.14790858307570992,583.1498672189412,5.131684826207889,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE315-72M,Chinaland Solar Energy,Mono-c-Si,0,315.0,284.6,1.9304999999999999,1.95,0.99,72.0,8.95,45.9,8.41,37.5,0.00503885,-0.1582173,46.1,1.9187818986230936,8.95622069670193,3.617254681898336e-10,0.3239262501323579,466.0475604181312,5.85708466901671,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE315-72P,Chinaland Solar Energy,Multi-c-Si,0,315.0,279.3,1.9304999999999999,1.95,0.99,72.0,8.93,44.3,8.44,37.3,0.0028843900000000006,-0.1617393,48.3,1.895966516003849,8.9317836047979,6.319820754224158e-10,0.15565436975406832,779.3172815095264,4.794845520811879,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE320-72M,Chinaland Solar Energy,Mono-c-Si,0,320.0,289.2,1.9304999999999999,1.95,0.99,72.0,9.04,45.1,8.48,37.7,0.00508952,-0.1554597,46.1,1.9122816894277666,9.045475092617426,5.094879461718571e-10,0.19648504717087975,324.41918405565207,8.755609988203854,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE320-72P,Chinaland Solar Energy,Multi-c-Si,0,320.0,283.8,1.9304999999999999,1.95,0.99,72.0,9.03,44.6,8.53,37.5,0.00291669,-0.1628346,48.3,1.9078196847901567,9.032036632428422,6.31078906872157e-10,0.16204135484256904,718.4575553742752,4.690327976382432,-0.4735,N,2025.7.3,6/23/2025,4.0,first_pass +Chinaland Solar Energy HSE325-72M,Chinaland Solar Energy,Mono-c-Si,0,325.0,293.9,1.9304999999999999,1.95,0.99,72.0,9.14,45.9,8.58,37.9,0.005145820000000001,-0.1582173,46.1,1.9316321689021945,9.146362846210996,4.321077089558087e-10,0.26218339308517186,376.6170882161668,7.214120060437191,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515,Chint New Energy Technology Co Ltd,Mono-c-Si,1,515.0,477.1,2.48,,,72.0,13.28082893,48.9,12.53271984,41.09243697,0.00632167457068,-0.1387782,45.63,1.8894595471248556,13.288473600757614,7.548778332115234e-11,0.15760797819590763,273.8070333131595,10.032577729785848,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-520,Chint New Energy Technology Co Ltd,Mono-c-Si,1,520.0,481.9,2.48,,,72.0,13.32154889,49.1,12.60285132,41.2605042,0.006341057271640001,-0.13934580000000002,45.63,1.8244023833904965,13.329107194439338,2.6996697502110293e-11,0.17049617601242673,300.5003546227178,1.2307125360731672,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-520,Chint New Energy Technology Co Ltd,Mono-c-Si,0,520.0,481.2,2.48,,,72.0,13.34,48.9,12.65439673,41.09243697,0.007323659999999999,-0.14313030000000002,45.52,1.9181421932517897,13.343418484916063,1.1244034357435125e-10,0.15184394974899446,592.5427398088415,9.990496956581724,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-525,Chint New Energy Technology Co Ltd,Mono-c-Si,1,525.0,486.7,2.48,,,72.0,13.39507827,49.3,12.67241379,41.42857143,0.0063760572565200015,-0.1399134,45.63,1.9024889733903951,13.401045518157112,7.388421803167705e-11,0.15791245784967026,354.4765914852892,9.755458201109567,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-525,Chint New Energy Technology Co Ltd,Mono-c-Si,0,525.0,486.0,2.48,,,72.0,13.43,49.1,12.72403259,41.2605042,0.00737307,-0.14371570000000003,45.52,1.9272008456837022,13.434276064989819,1.1486318801519497e-10,0.1512527253055288,475.0452127385286,10.125282909966584,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-530,Chint New Energy Technology Co Ltd,Mono-c-Si,1,530.0,491.4,2.48,,,72.0,13.4849757,49.5,12.74141414,41.59663866,0.0064188484332,-0.140481,45.63,1.9114221263594962,13.491861477144658,7.550350247054021e-11,0.15731250013879827,308.07783120515126,9.893691381973875,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-530,Chint New Energy Technology Co Ltd,Mono-c-Si,0,530.0,490.8,2.48,,,72.0,13.52,49.3,12.79310345,41.42857143,0.007422479999999999,-0.14430110000000002,45.52,1.9363025111713328,13.525161443259394,1.1737759529782036e-10,0.15066118862336603,394.6453063561719,10.263723929520543,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-535,Chint New Energy Technology Co Ltd,Mono-c-Si,1,535.0,496.2,2.48,,,72.0,13.57451138,49.7,12.80985915,41.76470588,0.006461467416880001,-0.14104860000000002,45.63,1.9203709519162642,13.582325099968976,7.715706557586673e-11,0.15672082280284305,272.26578930879907,10.032577861380583,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-535,Chint New Energy Technology Co Ltd,Mono-c-Si,0,535.0,495.6,2.48,,,72.0,13.61,49.5,12.86161616,41.59663866,0.007471889999999999,-0.1448865,45.52,1.9454469493347706,13.616074028558778,1.1998626982230317e-10,0.15006925373171134,336.2583167483762,10.405747759529634,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-540,Chint New Energy Technology Co Ltd,Mono-c-Si,1,540.0,501.0,2.48,,,72.0,13.66369102,49.9,12.87775551,41.93277311,0.00650391692552,-0.1416162,45.63,1.929335639779762,13.672441974065222,7.884582641211053e-11,0.15613708569988435,243.7915816818519,10.172130309757495,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-540,Chint New Energy Technology Co Ltd,Mono-c-Si,0,540.0,500.3,2.48,,,72.0,13.72,49.7,12.92957746,41.76470588,0.007532280000000001,-0.14547190000000002,45.52,1.9561047322849345,13.728013472065284,1.250272126227936e-10,0.14902574277496414,255.14948250730234,10.712630820060161,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-545,Chint New Energy Technology Co Ltd,Mono-c-Si,1,545.0,505.8,2.48,,,72.0,13.75252024,50.1,12.94510978,42.10084034,0.006546199634240002,-0.1421838,45.63,1.9383162787822954,13.762217559217884,8.057062812584613e-11,0.1555609773949857,220.61308644662844,10.312351870535137,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-545,Chint New Energy Technology Co Ltd,Mono-c-Si,0,545.0,505.1,2.48,,,72.0,13.81,49.9,12.99699399,41.93277311,0.0075816899999999994,-0.1460573,45.52,1.9653358742882985,13.81897578438864,1.2787637691217262e-10,0.14843443185629124,228.37887679943333,10.861156344444465,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-550,Chint New Energy Technology Co Ltd,Mono-c-Si,1,550.0,510.6,2.48,,,72.0,13.8235065,50.3,13.01192843,42.26890756,0.006579989094000001,-0.1427514,45.63,1.9460540706314124,13.833253874970781,8.098651115601281e-11,0.15537995618618478,220.35633970607512,10.312352170378709,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M-HC-550,Chint New Energy Technology Co Ltd,Mono-c-Si,0,550.0,509.9,2.48,,,72.0,13.9,50.1,13.06387226,42.10084034,0.0076311,-0.14664270000000001,45.52,1.9746093494793144,13.909963421069271,1.3083049659712202e-10,0.14784236579381346,206.25535390037797,11.013089984361313,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-550,Chint New Energy Technology Co Ltd,Mono-c-Si,1,550.0,520.1,2.58,,,72.0,13.76,50.1,13.06,42.1,0.0045408,-0.11472900000000001,45.42,1.6863990811513858,13.769675698812204,1.702783367050546e-12,0.19876633120576695,282.66947669203154,0.08988664567460443,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-550,Chint New Energy Technology Co Ltd,Mono-c-Si,0,550.0,520.3,2.58,,,72.0,13.7,50.25,13.13,41.88,0.005205999999999999,-0.11356500000000001,45.6,1.678910970311886,13.700210348284397,1.37447496600036e-12,0.23031567684801485,15000.474018087467,-0.4613383435142796,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-555,Chint New Energy Technology Co Ltd,Mono-c-Si,1,555.0,515.4,2.48,,,72.0,13.89393048,50.5,13.07821782,42.43697479,0.00661351090848,-0.143319,45.63,1.9537918596312898,13.903727512900684,8.139909690400274e-11,0.15520706554811053,220.11115366743917,10.312351357291911,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-555,Chint New Energy Technology Co Ltd,Mono-c-Si,1,555.0,525.0,2.58,,,72.0,13.84,50.3,13.13,42.27,0.0045672,-0.11518700000000001,45.42,1.6935007818722474,13.850139136067465,1.7229115257760502e-12,0.1982175491340044,270.5685043927112,0.1417394451332749,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-555,Chint New Energy Technology Co Ltd,Mono-c-Si,0,555.0,525.1,2.58,,,72.0,13.8,50.4,13.21,42.0,0.005244,-0.113904,45.6,1.6846829718833112,13.801487820404523,1.4014038211131591e-12,0.22975241910867586,2131.0257794209615,-0.3545419917992815,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-560,Chint New Energy Technology Co Ltd,Mono-c-Si,1,560.0,520.2,2.48,,,72.0,13.96379885,50.7,13.14398422,42.60504202,0.006646768252600001,-0.1438866,45.63,1.9615296537297577,13.973645150813006,8.180843323777318e-11,0.15504208586407361,219.87714667508843,10.31235269878534,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-560,Chint New Energy Technology Co Ltd,Mono-c-Si,1,560.0,529.8,2.58,,,72.0,13.93,50.5,13.2,42.44,0.0045969,-0.11564500000000001,45.42,1.7011374173503409,13.941268359178087,1.7592828561454341e-12,0.19749704497239937,244.14680019781594,0.2676231391564902,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-560,Chint New Energy Technology Co Ltd,Mono-c-Si,0,560.0,530.0,2.58,,,72.0,13.9,50.55,13.29,42.13,0.005282,-0.114243,45.6,1.6906311207519908,13.902779341806276,1.4331063526612531e-12,0.2283460720552111,1142.0007499664898,-0.222444571859052,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-565,Chint New Energy Technology Co Ltd,Mono-c-Si,1,565.0,534.7,2.58,,,72.0,14.02,50.7,13.26,42.61,0.0046266,-0.11610300000000001,45.42,1.7093412625729056,14.03308883261934,1.812302228156046e-12,0.19674508153005288,210.74194496611366,0.4711238662114896,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-565,Chint New Energy Technology Co Ltd,Mono-c-Si,0,565.0,534.8,2.58,,,72.0,14.0,50.7,13.37,42.25,0.00532,-0.114582,45.6,1.6963959560483084,14.00406218318876,1.460612966530742e-12,0.22780363448615154,785.1076002115376,-0.11800705605607562,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-570,Chint New Energy Technology Co Ltd,Mono-c-Si,1,570.0,539.5,2.58,,,72.0,14.1,50.9,13.33,42.77,0.004653,-0.11656100000000001,45.42,1.7162575652379706,14.113593242805635,1.8272383769461484e-12,0.19706491462503564,204.4115104418962,0.4941509376965699,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-570,Chint New Energy Technology Co Ltd,Mono-c-Si,0,570.0,539.7,2.58,,,72.0,14.1,50.85,13.45,42.38,0.005357999999999999,-0.11492100000000002,45.6,1.7023378448131155,14.105348948951312,1.4930642737597763e-12,0.2264275505391216,596.8702445513026,0.011727470102964046,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-575,Chint New Energy Technology Co Ltd,Mono-c-Si,1,575.0,544.3,2.58,,,72.0,14.19,51.1,13.39,42.94,0.004682700000000001,-0.11701900000000001,45.42,1.7244636573157774,14.205414950810002,1.881627137242029e-12,0.19632137019544027,180.72067039023383,0.6954594334033289,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-575,Chint New Energy Technology Co Ltd,Mono-c-Si,0,575.0,544.5,2.58,,,72.0,14.2,51.0,13.53,42.5,0.005396,-0.11526,45.6,1.708095721130831,14.20663703433773,1.5211456295293144e-12,0.2259050742719588,483.3261205237511,0.11387715713698182,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-580,Chint New Energy Technology Co Ltd,Mono-c-Si,1,580.0,549.2,2.58,,,72.0,14.28,51.3,13.45,43.11,0.0047124,-0.11747700000000001,45.42,1.7326734332643776,14.297231836919318,1.937260099616803e-12,0.19558317398025923,162.0795121568817,0.895688207829397,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-580,Chint New Energy Technology Co Ltd,Mono-c-Si,0,580.0,549.4,2.58,,,72.0,14.3,51.15,13.61,42.63,0.0054340000000000005,-0.115599,45.6,1.7140315365016439,14.307918983227282,1.5543453626717152e-12,0.22455818980759296,405.5043462412807,0.24131666100841045,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-585,Chint New Energy Technology Co Ltd,Mono-c-Si,0,585.0,557.4,2.7,,,66.0,15.53,47.99,14.38,40.67,0.0065226,-0.10989710000000001,42.8,1.6620280541068961,15.559107541348649,4.297834517539624e-12,0.1367490851166665,72.96093022281748,6.977804337561977,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585,Chint New Energy Technology Co Ltd,Mono-c-Si,1,585.0,554.0,2.58,,,72.0,14.36,51.5,13.52,43.27,0.0047388000000000005,-0.11793500000000001,45.42,1.7395859879027735,14.37775101530816,1.952473362178715e-12,0.195905777151191,158.481467808371,0.9162722929182262,-0.282,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-585,Chint New Energy Technology Co Ltd,Mono-c-Si,0,585.0,554.2,2.58,,,72.0,14.4,51.3,13.68,42.75,0.005472,-0.115938,45.6,1.7203220588605472,14.410024214392282,1.596517300411056e-12,0.2240462996099718,321.84732716500537,0.4160567663089591,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-590,Chint New Energy Technology Co Ltd,Mono-c-Si,0,590.0,562.2,2.7,,,66.0,15.61,48.14,14.46,40.8,0.0065562,-0.11024060000000001,42.8,1.6669555403344045,15.638887173859624,4.302051108959945e-12,0.13628917479929512,73.64770366326175,6.939202503550413,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-590,Chint New Energy Technology Co Ltd,Mono-c-Si,1,590.0,558.9,2.58,,,72.0,14.45,51.7,13.58,43.45,0.0047685,-0.11839300000000001,45.42,1.7479833527350335,14.469496693398717,2.015775176083803e-12,0.19434140505743525,144.0363884689939,1.1406832890414662,-0.282,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-590,Chint New Energy Technology Co Ltd,Mono-c-Si,0,590.0,559.0,2.58,,,72.0,14.5,51.45,13.76,42.88,0.005509999999999999,-0.11627700000000002,45.6,1.7262521753192437,14.51129966037523,1.630707550832346e-12,0.22272659930634475,285.8082070831945,0.5410717845902835,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-590,Chint New Energy Technology Co Ltd,Mono-c-Si,1,590.0,558.4,2.7,,,72.0,14.5,51.0,13.77,42.86,0.00609,-0.11424000000000001,45.88,1.7180265785283024,14.509604458047583,1.8374426363169356e-12,0.19144983396899806,289.0347958948348,2.398761028087249,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-590,Chint New Energy Technology Co Ltd,Mono-c-Si,0,590.0,557.9,2.59,,,72.0,14.5,51.0,13.77,42.86,0.005509999999999999,-0.11628000000000001,46.18,1.722095667954099,14.509486398993033,1.9711491854516953e-12,0.1907682911612047,291.59012033568035,1.24180921066201,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-595,Chint New Energy Technology Co Ltd,Mono-c-Si,0,595.0,567.1,2.7,,,66.0,15.7,48.29,14.54,40.92,0.006594,-0.1105841,42.8,1.6721943174543115,15.729352934317115,4.329082319719715e-12,0.1364636263806668,72.99028137510876,6.944760775451952,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-595,Chint New Energy Technology Co Ltd,Mono-c-Si,1,595.0,563.7,2.58,,,72.0,14.53,51.9,13.64,43.61,0.0047948999999999995,-0.11885100000000001,45.42,1.755470776588351,14.550716591347577,2.0492322538527555e-12,0.19462525922057838,136.50435875405333,1.2379652495122329,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-595,Chint New Energy Technology Co Ltd,Mono-c-Si,0,595.0,563.9,2.58,,,72.0,14.6,51.6,13.84,43.0,0.005547999999999999,-0.11661600000000001,45.6,1.7319966935667424,14.612599518364595,1.6601264423371988e-12,0.22224134401922693,257.52758240335976,0.6386231607286385,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-595,Chint New Energy Technology Co Ltd,Mono-c-Si,1,595.0,563.2,2.7,,,72.0,14.56,51.2,13.83,43.03,0.0061152,-0.114688,45.88,1.724635079850515,14.569429405668314,1.841418390670855e-12,0.19126156944331346,295.32809927054905,2.3809115274243164,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-595,Chint New Energy Technology Co Ltd,Mono-c-Si,0,595.0,562.7,2.59,,,72.0,14.56,51.2,13.83,42.03,0.0055328,-0.116736,46.18,1.710341801467929,14.571054279355064,1.4400588258872e-12,0.27252529649795654,358.9531433374484,-1.4217281645167912,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-600,Chint New Energy Technology Co Ltd,Mono-c-Si,0,600.0,571.9,2.7,,,66.0,15.78,48.44,14.62,41.05,0.0066276,-0.1109276,42.8,1.6771238367633716,15.809131774542386,4.33338414878597e-12,0.13600969524607054,73.6732666026238,6.906794711390824,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-600,Chint New Energy Technology Co Ltd,Mono-c-Si,1,600.0,568.6,2.58,,,72.0,14.61,52.1,13.7,43.78,0.004821300000000001,-0.11930900000000001,45.42,1.763144632618495,14.63186159797185,2.089468315706329e-12,0.19407927071264264,129.70223629998378,1.360741467478072,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72N-HC-600,Chint New Energy Technology Co Ltd,Mono-c-Si,0,600.0,568.8,2.58,,,72.0,14.69,51.75,13.91,43.13,0.0055822,-0.11695499999999999,45.6,1.737949797678934,14.703903602465067,1.6946721050639822e-12,0.22109872199899255,233.60422138831436,0.7654199677923915,-0.278,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-600,Chint New Energy Technology Co Ltd,Mono-c-Si,1,600.0,568.0,2.7,,,72.0,14.65,51.4,13.89,43.19,0.006153000000000001,-0.115136,45.88,1.7326074874404498,14.661283516164989,1.8884458084990495e-12,0.1914010512257646,248.5063486536717,2.5525812314793663,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-600,Chint New Energy Technology Co Ltd,Mono-c-Si,0,600.0,567.6,2.59,,,72.0,14.65,51.4,13.89,43.19,0.005567000000000001,-0.117192,46.18,1.7367178755103336,14.661158371660374,2.0260060387020165e-12,0.19071835307885096,250.39709732511224,1.3942429231983882,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-605,Chint New Energy Technology Co Ltd,Mono-c-Si,0,605.0,576.8,2.7,,,66.0,15.86,48.59,14.69,41.18,0.0066612,-0.11127110000000001,42.8,1.6825966100015173,15.889458692635783,4.37482346466202e-12,0.13549114507297316,72.94585636268121,6.9474925748017204,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-605,Chint New Energy Technology Co Ltd,Mono-c-Si,1,605.0,572.9,2.7,,,72.0,14.71,51.6,13.95,43.36,0.006178200000000001,-0.115584,45.88,1.739215272246355,14.721106617317902,1.8923384655831973e-12,0.1912148386590136,253.2517512585959,2.5341767133721413,-0.275,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-605,Chint New Energy Technology Co Ltd,Mono-c-Si,0,605.0,572.4,2.59,,,72.0,14.71,51.6,13.95,43.36,0.0055898,-0.117648,46.18,1.7433405057203955,14.720981824901136,2.0301646231215804e-12,0.19053263547390095,255.2157856366018,1.376000438743489,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-610,Chint New Energy Technology Co Ltd,Mono-c-Si,0,610.0,581.7,2.7,,,66.0,15.94,48.74,14.77,41.31,0.0066948,-0.11161460000000002,42.8,1.6875276046503354,15.969238460339652,4.379153559718473e-12,0.13504665049330394,73.62369921980756,6.909985056654327,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-610,Chint New Energy Technology Co Ltd,Mono-c-Si,1,610.0,577.7,2.7,,,72.0,14.79,51.8,14.01,43.53,0.006211800000000001,-0.11603200000000001,45.88,1.7468550395981866,14.802263032625913,1.92934194416738e-12,0.19070697202312456,230.00477989647567,2.658961175791209,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-610,Chint New Energy Technology Co Ltd,Mono-c-Si,0,610.0,577.3,2.59,,,72.0,14.79,51.8,14.01,43.53,0.0056202,-0.11810400000000001,46.18,1.7510037989007088,14.802133598988956,2.06997707230306e-12,0.19002361485393282,231.62536261187586,1.4996366418712224,-0.28,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-615,Chint New Energy Technology Co Ltd,Mono-c-Si,0,615.0,586.6,2.7,,,66.0,16.02,48.89,14.84,41.43,0.006728400000000001,-0.1119581,42.8,1.6928050503628138,16.049725827231356,4.40606939479201e-12,0.13530386644203649,72.91867523176587,6.921115503177452,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-615,Chint New Energy Technology Co Ltd,Mono-c-Si,1,615.0,582.6,2.7,,,72.0,14.86,52.0,14.07,43.7,0.006241200000000001,-0.11648,45.88,1.753978866649233,14.87275145655217,1.949916460961919e-12,0.19036433973302508,221.84242863523858,2.711543794172967,-0.275,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-615,Chint New Energy Technology Co Ltd,Mono-c-Si,0,615.0,582.1,2.59,,,72.0,14.86,52.0,14.07,43.7,0.0056468,-0.11856000000000001,46.18,1.7581468449936726,14.872619897207013,2.092100244474061e-12,0.189680652134963,223.350035815392,1.5517360754680647,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-620,Chint New Energy Technology Co Ltd,Mono-c-Si,0,620.0,591.4,2.7,,,66.0,16.11,49.04,14.92,41.56,0.0067662,-0.1123016,42.8,1.698236563190697,16.140030632077053,4.4475719868633425e-12,0.13471802635215116,72.26978772202324,6.955513762616214,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN(DG)/F-BH-620,Chint New Energy Technology Co Ltd,Mono-c-Si,1,620.0,587.4,2.7,,,72.0,14.94,52.2,14.13,43.87,0.0062748000000000005,-0.116928,45.88,1.7616200410576084,14.953903763484128,1.9875838268661163e-12,0.18986388806830284,204.0142938353202,2.834879395516359,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM72RN-HC-620,Chint New Energy Technology Co Ltd,Mono-c-Si,0,620.0,587.0,2.59,,,72.0,14.94,52.2,14.13,43.87,0.0056772,-0.11901600000000001,46.18,1.7658116110682216,14.953767518656063,2.132631684480152e-12,0.18917905051986048,205.29008072657257,1.6739437985074423,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-625,Chint New Energy Technology Co Ltd,Mono-c-Si,0,625.0,596.3,2.7,,,66.0,16.19,49.19,14.99,41.69,0.006799800000000001,-0.11264510000000001,42.8,1.703707255982122,16.22035617553825,4.489171110469741e-12,0.1342164766565303,71.58229649719837,6.995291116358203,-0.284,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-630,Chint New Energy Technology Co Ltd,Mono-c-Si,0,630.0,601.2,2.7,,,66.0,16.27,49.34,15.07,41.82,0.006833400000000001,-0.11298860000000002,42.8,1.7086398740856377,16.300135460705178,4.493422904811167e-12,0.13378714283977358,72.23107806782151,6.95830673553505,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-635,Chint New Energy Technology Co Ltd,Mono-c-Si,1,635.0,589.0,3.03,,,66.0,18.17,44.89,17.13,37.08,0.009085000000000001,-0.1306299,44.8,1.7474802299702636,18.183117391408775,1.253081294905733e-10,0.14552956728715663,201.58522716726222,8.941697880593075,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-640,Chint New Energy Technology Co Ltd,Mono-c-Si,1,640.0,593.7,3.03,,,66.0,18.22,45.09,17.17,37.28,0.00911,-0.1312119,44.8,1.7565092306825558,18.233575912513217,1.2788341362251682e-10,0.14340162533923068,192.45687503292191,9.097872349436676,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-645,Chint New Energy Technology Co Ltd,Mono-c-Si,1,645.0,598.5,3.03,,,66.0,18.27,45.29,17.21,37.48,0.009135,-0.1317939,44.8,1.765540033403836,18.284012055502792,1.3049078625527782e-10,0.14128251605453887,184.21506021149608,9.254106906565495,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-645,Chint New Energy Technology Co Ltd,Mono-c-Si,0,645.0,597.2,3.02,,,66.0,18.38,45.08,17.32,37.25,0.00919,-0.1311828,45.4,1.755612074317279,18.393836373009247,1.2805360049233425e-10,0.14357491254208635,190.72245130177552,9.033221998269497,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-650,Chint New Energy Technology Co Ltd,Mono-c-Si,1,650.0,603.3,3.03,,,66.0,18.32,45.49,17.26,37.68,0.00916,-0.1323759,44.8,1.774053692669469,18.333694701342925,1.322255516374601e-10,0.13921135092675266,186.22910892397007,9.346082816199484,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-650,Chint New Energy Technology Co Ltd,Mono-c-Si,0,650.0,601.9,3.02,,,66.0,18.43,45.28,17.36,37.45,0.009215,-0.13176480000000002,45.4,1.764640117345444,18.444278317784658,1.306624843824948e-10,0.14147461330494435,182.61095197836198,9.188832941547387,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-655,Chint New Energy Technology Co Ltd,Mono-c-Si,1,655.0,608.1,3.03,,,66.0,18.37,45.69,17.3,37.88,0.009185,-0.1329579,44.8,1.7830880088906507,18.38410030643988,1.3488342465283608e-10,0.13711291749128585,178.6318885988593,9.499687267644155,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-655,Chint New Energy Technology Co Ltd,Mono-c-Si,0,655.0,606.7,3.02,,,66.0,18.48,45.48,17.41,37.65,0.009240000000000002,-0.1323468,45.4,1.7731556170901517,18.493958370149315,1.324050526660201e-10,0.13942017028089235,184.58350074543114,9.281340360979712,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-655,Chint New Energy Technology Co Ltd,Mono-c-Si,1,655.0,619.0,3.11,,,66.0,17.54,46.56,16.95,38.64,0.0063143999999999995,-0.1098816,44.6,1.5933727811774072,17.5400030516111,3.576799108271911e-12,0.14837617644764967,852838.2329361871,1.1215649036564106,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66N-HC-655,Chint New Energy Technology Co Ltd,Mono-c-Si,0,655.0,617.4,3.11,,,66.0,17.64,46.36,17.03,38.47,0.0068796000000000005,-0.1117276,45.0,1.6071277606783134,17.640003031403896,5.23147911285835e-12,0.1457874253770551,848355.3335263911,2.078448222951189,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-660,Chint New Energy Technology Co Ltd,Mono-c-Si,1,660.0,612.9,3.03,,,66.0,18.42,45.89,17.34,38.08,0.009210000000000001,-0.1335399,44.8,1.7921251264062832,18.43448441091583,1.375750684926673e-10,0.1350236780160756,171.71124421342964,9.652289031945518,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-660,Chint New Energy Technology Co Ltd,Mono-c-Si,0,660.0,611.5,3.02,,,66.0,18.53,45.68,17.45,37.85,0.009265,-0.13292879999999999,45.4,1.7821866364171686,18.54436961699704,1.350636985587091e-10,0.13733991698980264,177.10344946410947,9.434868998446738,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-660,Chint New Energy Technology Co Ltd,Mono-c-Si,1,660.0,623.9,3.11,,,66.0,17.62,46.76,17.01,38.8,0.0063432,-0.1103536,44.6,1.5994718709962428,17.62000313763085,3.5445209118998054e-12,0.1516950248452858,851878.1916663536,1.0076732375108794,-0.296,N,2025.7.3,6/23/2025,2.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N-HC-660,Chint New Energy Technology Co Ltd,Mono-c-Si,0,660.0,622.2,3.11,,,66.0,17.72,46.56,17.08,38.64,0.0069108,-0.11220959999999999,45.0,1.6130887243051717,17.720003138963612,5.1646211104615334e-12,0.15004994079887798,847064.0555861295,1.9322914232987416,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-665,Chint New Energy Technology Co Ltd,Mono-c-Si,1,665.0,617.7,3.03,,,66.0,18.47,46.09,17.38,38.28,0.009235,-0.1341219,44.8,1.801165023115953,18.48484737096238,1.4030062222674704e-10,0.13294356631976378,165.38064174536245,9.803905805167618,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-665,Chint New Energy Technology Co Ltd,Mono-c-Si,0,665.0,616.3,3.02,,,66.0,18.58,45.88,17.5,38.05,0.00929,-0.1335108,45.4,1.7907010067749272,18.5940459580826,1.3682870987661394e-10,0.13530856008040842,178.98623267905867,9.525356424742673,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-665,Chint New Energy Technology Co Ltd,Mono-c-Si,1,665.0,628.7,3.11,,,66.0,17.7,46.96,17.06,38.97,0.006371999999999999,-0.1108256,44.6,1.605361142357337,17.70000324521924,3.499422142325306e-12,0.15593957421875396,850526.207904476,0.8628258187432819,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66N-HC-665,Chint New Energy Technology Co Ltd,Mono-c-Si,0,665.0,627.1,3.11,,,66.0,17.8,46.76,17.14,38.81,0.006942000000000001,-0.1126916,45.0,1.6196757229811147,17.800229049963768,5.155342815681734e-12,0.1520368156643758,11815.13121336094,1.8801842679092944,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-670,Chint New Energy Technology Co Ltd,Mono-c-Si,1,670.0,622.5,3.03,,,66.0,18.52,46.29,17.42,38.48,0.009260000000000001,-0.1347039,44.8,1.8102076780545855,18.535189532994966,1.4306022208374227e-10,0.1308725185992355,159.5677142144405,9.954550662222,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-670,Chint New Energy Technology Co Ltd,Mono-c-Si,0,670.0,621.1,3.02,,,66.0,18.63,46.08,17.54,38.23,0.009315,-0.13409279999999998,45.4,1.799231705663899,18.644522975068853,1.385486387770051e-10,0.13457074303298394,172.6266831228703,9.613786051386635,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-670,Chint New Energy Technology Co Ltd,Mono-c-Si,1,670.0,633.5,3.11,,,66.0,17.78,47.17,17.12,39.14,0.0064008,-0.1113212,44.6,1.6120709130784188,17.78023705597087,3.4847141694926755e-12,0.15845770211704982,11884.863662472262,0.790862163129177,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66N-HC-670,Chint New Energy Technology Co Ltd,Mono-c-Si,0,670.0,631.9,3.11,,,66.0,17.88,46.96,17.19,38.97,0.0069732,-0.1131736,45.0,1.6254745607289973,17.880237582603975,5.0757268449816394e-12,0.1566053948486622,11785.814978855442,1.7119509158094894,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-675,Chint New Energy Technology Co Ltd,Mono-c-Si,1,675.0,627.2,3.03,,,66.0,18.57,46.49,17.46,38.68,0.009285,-0.13528590000000001,44.8,1.8192530848242192,18.585511235008056,1.458540266638436e-10,0.12881047684000257,154.211487025828,10.104225278419719,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66M-HC-675,Chint New Energy Technology Co Ltd,Mono-c-Si,0,675.0,625.8,3.02,,,66.0,18.68,46.28,17.58,38.42,0.00934,-0.1346748,45.4,1.8080164739499438,18.694941359700742,1.4077774143995417e-10,0.13317589909904248,166.49929553574935,9.733144759730013,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-675,Chint New Energy Technology Co Ltd,Mono-c-Si,1,675.0,638.4,3.11,,,66.0,17.86,47.37,17.17,39.31,0.0064296,-0.1117932,44.6,1.6180272751604003,17.86030811474765,3.4450155068280246e-12,0.1622695935027581,9406.025161190992,0.6580673759007165,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66N-HC-675,Chint New Energy Technology Co Ltd,Mono-c-Si,0,675.0,636.7,3.11,,,66.0,17.96,47.17,17.24,39.14,0.0070044,-0.1136797,45.0,1.6315503358358645,17.960274128409864,4.9917838854206495e-12,0.16848433132984117,11038.544856107377,1.5348536928168868,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-680,Chint New Energy Technology Co Ltd,Mono-c-Si,1,680.0,643.2,3.11,,,66.0,17.94,47.57,17.22,39.48,0.0064583999999999996,-0.1122652,44.6,1.6236194699517086,17.940002989115833,3.38486623258133e-12,0.16661480384590324,999990.5340720408,0.4730405056743538,-0.296,N,2025.7.3,6/23/2025,2.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N-HC-680,Chint New Energy Technology Co Ltd,Mono-c-Si,0,680.0,641.6,3.11,,,66.0,18.03,47.37,17.3,39.31,0.007031700000000001,-0.1141617,45.0,1.6382849950008278,18.030282554320884,4.9950433768089184e-12,0.1683384813021594,10741.803211610382,1.5077758083551367,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-685,Chint New Energy Technology Co Ltd,Mono-c-Si,1,685.0,649.0,3.11,,,66.0,18.23,47.77,17.28,39.65,0.0078389,-0.1285013,43.6,1.6755919073711985,18.242993937771047,7.494122080136451e-12,0.16530909647632924,231.92236954063188,-6.1337975601125265,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N-HC-685,Chint New Energy Technology Co Ltd,Mono-c-Si,0,685.0,646.4,3.11,,,66.0,18.11,47.57,17.35,39.48,0.0070629,-0.1146437,45.0,1.6440872956101087,18.110003002719445,4.920923387834596e-12,0.1658029203696922,999999.0453289397,1.3447721697453865,-0.303,N,2025.7.3,6/23/2025,2.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-690,Chint New Energy Technology Co Ltd,Mono-c-Si,1,690.0,653.9,3.11,,,66.0,18.28,47.97,17.33,39.82,0.0078604,-0.12903930000000002,43.6,1.6825731842957659,18.292805755524167,7.511598624078238e-12,0.1652871464736667,235.94461420566216,-6.137556759694539,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N-HC-690,Chint New Energy Technology Co Ltd,Mono-c-Si,0,690.0,651.2,3.11,,,66.0,18.19,47.78,17.4,39.65,0.0070941,-0.1151498,45.0,1.6508489130134338,18.19061645615667,4.8974473866953415e-12,0.16874158869344758,4979.120673269812,1.2698499137482928,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-695,Chint New Energy Technology Co Ltd,Mono-c-Si,1,695.0,658.7,3.11,,,66.0,18.33,48.17,17.38,39.98,0.007881899999999999,-0.1295773,43.6,1.689347194495923,18.342643215541592,7.502976407243305e-12,0.16592230330079707,240.55239892177423,-6.168087212311226,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N-HC-695,Chint New Energy Technology Co Ltd,Mono-c-Si,0,695.0,656.1,3.11,,,66.0,18.27,47.98,17.46,39.82,0.0071253,-0.11563179999999999,45.0,1.6585239484933731,18.272006269257766,4.979550185602095e-12,0.16843595266201705,1533.8543837638772,1.376541325790748,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-700,Chint New Energy Technology Co Ltd,Mono-c-Si,1,700.0,663.6,3.11,,,66.0,18.38,48.37,17.44,40.15,0.0079034,-0.1301153,43.6,1.6958798013063556,18.39163688858746,7.469003761705098e-12,0.16591114848472133,262.0500225928951,-6.226917843005759,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-705,Chint New Energy Technology Co Ltd,Mono-c-Si,1,705.0,668.4,3.11,,,66.0,18.43,48.57,17.49,40.31,0.007924899999999999,-0.1306533,43.6,1.70265315234697,18.441470862587895,7.46080358170024e-12,0.1665407182383098,267.5775622275071,-6.256940647682918,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-710,Chint New Energy Technology Co Ltd,Mono-c-Si,1,710.0,673.3,3.11,,,66.0,18.48,48.77,17.54,40.48,0.007946400000000001,-0.1311913,43.6,1.7096328073914757,18.491285216633234,7.478315847478088e-12,0.16651588092322006,272.6765104360768,-6.26029562071128,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-715,Chint New Energy Technology Co Ltd,Mono-c-Si,1,715.0,678.1,3.11,,,66.0,18.53,48.97,17.59,40.65,0.0079679,-0.13172930000000002,43.6,1.7166121723613075,18.5411002590206,7.495804100946701e-12,0.16649124255821524,277.92889583938535,-6.263671553854379,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-720,Chint New Energy Technology Co Ltd,Mono-c-Si,1,720.0,683.0,3.11,,,66.0,18.58,49.17,17.64,40.81,0.007989399999999999,-0.1322673,43.6,1.7233848580074045,18.590932797628838,7.487814564046798e-12,0.16711394547149025,284.00572506981734,-6.2932586795116965,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-725,Chint New Energy Technology Co Ltd,Mono-c-Si,1,725.0,687.8,3.11,,,66.0,18.63,49.37,17.69,40.98,0.0080109,-0.1328053,43.6,1.7303637120248918,18.640748382475156,7.505303945248909e-12,0.16708791853182486,289.6108266379785,-6.29656420371235,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-730,Chint New Energy Technology Co Ltd,Mono-c-Si,1,730.0,692.7,3.11,,,66.0,18.67,49.57,17.7,41.24,0.008028100000000002,-0.13334330000000003,43.6,1.7405815553724655,18.682812965885752,7.911246113218065e-12,0.16130941781110733,235.04681635509175,-5.899738453204673,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Chint New Energy Technology Co Ltd CHSM66N(DG)/F-BH-735,Chint New Energy Technology Co Ltd,Mono-c-Si,1,735.0,697.6,3.11,,,66.0,18.72,49.77,17.75,41.41,0.008049599999999999,-0.1338813,43.6,1.7475604783306458,18.732633297158877,7.928064929035729e-12,0.16129984219809648,239.01385495224682,-5.904530457705991,-0.304,N,2025.7.3,6/23/2025,4.0,bootstrapping +Convalt Manufacturing LLC CVLT390-108M-BB,Convalt Manufacturing LLC,Mono-c-Si,0,390.0,358.4,1.94,,,54.0,13.5,36.84,12.66,30.82,0.008505,-0.11494080000000002,45.8,1.4785961529590594,13.500003071413872,2.040123144288612e-10,0.11916423234083313,523839.3647949069,7.991698016058665,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT395-108M-BB,Convalt Manufacturing LLC,Mono-c-Si,0,395.0,363.2,1.94,,,54.0,13.59,37.03,12.75,31.0,0.0085617,-0.1155336,45.8,1.4624779000529269,13.601599785803595,1.345383100407165e-10,0.12145129475423784,142.28910461625114,4.42423986704495,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT400-108M-BB,Convalt Manufacturing LLC,Mono-c-Si,0,400.0,367.9,1.94,,,54.0,13.68,37.2,12.84,31.17,0.0086184,-0.11606400000000001,45.8,1.466879831844951,13.691267680585728,1.3017469701317018e-10,0.11921050390236448,144.7325134401075,4.090064130181756,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT405-108M-BB,Convalt Manufacturing LLC,Mono-c-Si,0,405.0,372.7,1.94,,,54.0,13.78,37.36,12.92,31.36,0.0086814,-0.11656319999999999,45.8,1.523529296516155,13.78997075969155,3.0314766682000675e-10,0.10562700816659162,145.98087711941233,11.37759944316438,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT530-144BMH,Convalt Manufacturing LLC,Mono-c-Si,1,530.0,490.6,2.54,,,72.0,13.71,49.35,12.82,41.35,0.0085002,-0.1426215,45.9,1.9399714918921391,13.72428100293305,1.2003946190525933e-10,0.1589338983664807,152.5791849078758,11.723050968087001,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT535-144BMH,Convalt Manufacturing LLC,Mono-c-Si,1,535.0,495.4,2.54,,,72.0,13.78,49.5,12.9,41.5,0.0085436,-0.143055,45.9,1.9453407703765808,13.793377680361399,1.1997666765744489e-10,0.15659498539376066,161.30441769689926,11.668031867547443,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT535-144BMH-DG,Convalt Manufacturing LLC,Mono-c-Si,1,535.0,499.6,2.58,,,72.0,13.78,49.5,12.9,41.5,0.0053742,-0.128205,46.0,1.8010358200603587,13.798127003241019,1.5564812057464584e-11,0.18141528344981359,137.9104191114785,6.015259580460173,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT535-144MH,Convalt Manufacturing LLC,Mono-c-Si,0,535.0,494.6,2.54,,,72.0,13.78,49.5,12.9,41.5,0.0077168,-0.145035,45.8,1.9548582446819707,13.793092364517085,1.3583133771545012e-10,0.1549827366890791,163.12272337798038,11.313940808894646,-0.383,N,2025.7.3,6/23/2025,4.0,bootstrapping +Convalt Manufacturing LLC CVLT540-144BMH,Convalt Manufacturing LLC,Mono-c-Si,1,540.0,500.2,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008587000000000001,-0.1434885,45.9,1.9514963094359852,13.863041506963729,1.210390588527749e-10,0.15416260637215692,163.71974046179957,11.700700927777648,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT540-144BMH-DG,Convalt Manufacturing LLC,Mono-c-Si,1,540.0,504.4,2.58,,,72.0,13.85,49.65,12.97,41.65,0.0054015,-0.1285935,46.0,1.806718023921159,13.867746397271825,1.5702919886882438e-11,0.17893833998811529,139.65065563852826,6.046415169278489,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT540-144MH,Convalt Manufacturing LLC,Mono-c-Si,0,540.0,499.4,2.54,,,72.0,13.85,49.65,12.97,41.65,0.007756000000000001,-0.14547449999999998,45.8,1.9610452243433347,13.862759201611965,1.3703419759435706e-10,0.15255321430895627,165.59516233746885,11.34644683198243,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Convalt Manufacturing LLC CVLT545-144BMH,Convalt Manufacturing LLC,Mono-c-Si,1,545.0,504.9,2.54,,,72.0,13.92,49.81,13.04,41.8,0.0086304,-0.1439509,45.9,1.9578351168277035,13.932764529358916,1.2177458142777877e-10,0.15253259497097293,166.3401526177363,11.708645363577327,-0.374,N,2025.7.3,6/23/2025,2.0,first_pass +Convalt Manufacturing LLC CVLT545-144BMH-DG,Convalt Manufacturing LLC,Mono-c-Si,1,545.0,509.1,2.58,,,72.0,13.92,49.81,13.04,41.8,0.005428799999999999,-0.1290079,46.0,1.8125824197321938,13.93743487261863,1.5798155719804263e-11,0.17726085626943738,141.52504464536676,6.053709378493165,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Convalt Manufacturing LLC CVLT545-144MH,Convalt Manufacturing LLC,Mono-c-Si,0,545.0,504.2,2.54,,,72.0,13.92,49.81,13.04,41.8,0.0077951999999999995,-0.1459433,45.8,1.967414939231386,13.93248459164255,1.3786629719233134e-10,0.15092635001249916,168.27901935007975,11.35429412040548,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT550-144BMH-DG,Convalt Manufacturing LLC,Mono-c-Si,1,550.0,513.9,2.58,,,72.0,13.99,49.92,13.1,42.0,0.0054561,-0.1292928,46.0,1.8193053448853478,14.007031942336134,1.6531366191289785e-11,0.16730050122063675,137.42026441981295,6.404856701814851,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Convalt Manufacturing LLC CVLT550-144MH,Convalt Manufacturing LLC,Mono-c-Si,0,550.0,508.9,2.54,,,72.0,13.99,49.92,13.1,42.0,0.0078344,-0.1462656,45.8,1.9749348064250536,14.002138182442192,1.4420694503148242e-10,0.14090063311015055,162.39662789050388,11.71661549874767,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Crossroads Solar Crossroads Solar 380,Crossroads Solar,Mono-c-Si,0,380.0,350.5,2.04,,,12.0,9.9,49.0,9.35,40.64,0.0048906,-0.135975,45.8,1.8872939678378584,9.906119857107822,5.1933060900874454e-11,0.2765239057200161,447.3285395811579,11.789198568144453,-0.3779,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-200P,CSI Solar Co Ltd,Multi-c-Si,0,200.0,183.0,1.6085159999999998,1.638,0.982,60.0,7.68,36.2,6.93,28.9,0.0027647999999999995,-0.125614,43.6,1.4542426507090545,7.723877018520308,1.1196554504823206e-10,0.4288971505125813,75.07187821752379,-2.766849735175148,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-200PX,CSI Solar Co Ltd,Multi-c-Si,0,200.0,183.0,1.6085159999999998,1.638,0.982,60.0,7.68,36.2,6.93,28.9,0.0027647999999999995,-0.125614,43.6,1.4542426507090545,7.723877018520308,1.1196554504823206e-10,0.4288971505125813,75.07187821752379,-2.766849735175148,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-205M,CSI Solar Co Ltd,Mono-c-Si,0,205.0,184.7,1.5487849999999999,1.615,0.959,60.0,7.66,36.5,7.02,29.2,0.00383766,-0.1331155,46.0,1.5096581494169923,7.687039091740303,2.3296501049896835e-10,0.4074178583851335,115.41885396418253,-2.108005445708437,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-205P,CSI Solar Co Ltd,Multi-c-Si,0,205.0,187.6,1.6085159999999998,1.638,0.982,60.0,7.6,36.2,7.1,28.9,0.0027359999999999997,-0.125614,43.6,1.427583436171653,7.612980427260074,7.25589010216185e-11,0.43286668864842326,253.44211973951775,-6.129913577261818,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-205PX,CSI Solar Co Ltd,Multi-c-Si,0,205.0,187.6,1.6085159999999998,1.638,0.982,60.0,7.6,36.2,7.1,28.9,0.0027359999999999997,-0.125614,43.6,1.427583436171653,7.612980427260074,7.25589010216185e-11,0.43286668864842326,253.44211973951775,-6.129913577261818,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-210M,CSI Solar Co Ltd,Mono-c-Si,0,210.0,189.3,1.5487849999999999,1.615,0.959,60.0,7.77,36.7,7.17,29.3,0.0038927699999999994,-0.13384490000000002,46.0,1.510350425214302,7.792042992164439,2.1109702099249246e-10,0.4139687864172876,145.9211015811122,-3.016024040171402,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-210P,CSI Solar Co Ltd,Multi-c-Si,0,210.0,192.3,1.6085159999999998,1.638,0.982,60.0,7.91,36.4,7.26,28.9,0.0028476,-0.12630799999999998,43.6,1.4441612166105855,7.941279181965225,8.618860066506342e-11,0.4446738024653277,112.45082695779243,-5.071244441400478,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-210PX,CSI Solar Co Ltd,Multi-c-Si,0,210.0,192.3,1.6085159999999998,1.638,0.982,60.0,7.91,36.4,7.26,28.9,0.0028476,-0.12630799999999998,43.6,1.4441612166105855,7.941279181965225,8.618860066506342e-11,0.4446738024653277,112.45082695779243,-5.071244441400478,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-215M,CSI Solar Co Ltd,Mono-c-Si,0,215.0,193.9,1.5487849999999999,1.615,0.959,60.0,7.89,36.8,7.33,29.3,0.00395289,-0.1342096,46.0,1.5065509765709706,7.906741071213197,1.9025897216105922e-10,0.42170785608592226,198.74924660002108,-3.965307226029173,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-215P,CSI Solar Co Ltd,Multi-c-Si,0,215.0,197.0,1.6085159999999998,1.638,0.982,60.0,8.01,36.5,7.43,29.0,0.0028836,-0.126655,43.6,1.440748381220247,8.031048543433378,7.767529037479102e-11,0.4364805999711505,166.10221747564702,-5.990302888727115,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-215PX,CSI Solar Co Ltd,Multi-c-Si,0,215.0,197.0,1.6085159999999998,1.638,0.982,60.0,8.01,36.5,7.43,29.0,0.0028836,-0.126655,43.6,1.440748381220247,8.031048543433378,7.767529037479102e-11,0.4364805999711505,166.10221747564702,-5.990302888727115,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-220M,CSI Solar Co Ltd,Mono-c-Si,0,220.0,198.5,1.5487849999999999,1.615,0.959,60.0,7.97,36.9,7.45,29.5,0.003992969999999999,-0.1345743,46.0,1.509349879375973,7.981006162599724,1.8949402116591638e-10,0.3993708573642383,289.20035494466384,-4.092200930605349,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-220P,CSI Solar Co Ltd,Multi-c-Si,0,220.0,201.6,1.6085159999999998,1.638,0.982,60.0,8.09,36.6,7.52,29.3,0.0029124,-0.127002,43.6,1.4493350955693902,8.10817167046645,8.521490370863418e-11,0.39872516485546994,177.51184265485858,-5.3675694204599065,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-220PX,CSI Solar Co Ltd,Multi-c-Si,0,220.0,201.6,1.6085159999999998,1.638,0.982,60.0,8.09,36.6,7.52,29.3,0.0029124,-0.127002,43.6,1.4493350955693902,8.10817167046645,8.521490370863418e-11,0.39872516485546994,177.51184265485858,-5.3675694204599065,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-225P,CSI Solar Co Ltd,Multi-c-Si,0,225.0,206.3,1.6085159999999998,1.638,0.982,60.0,8.19,36.7,7.63,29.5,0.0029484,-0.12734900000000002,43.6,1.4549653176271873,8.205848699542651,8.900021247481888e-11,0.3764204867654771,194.51967683964273,-5.136226898517695,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-225PX,CSI Solar Co Ltd,Multi-c-Si,0,225.0,206.3,1.6085159999999998,1.638,0.982,60.0,8.19,36.7,7.63,29.5,0.0029484,-0.12734900000000002,43.6,1.4549653176271873,8.205848699542651,8.900021247481888e-11,0.3764204867654771,194.51967683964273,-5.136226898517695,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-230M,CSI Solar Co Ltd,Mono-c-Si,0,230.0,207.8,1.5487849999999999,1.615,0.959,60.0,8.22,37.1,7.7,29.9,0.0041182200000000006,-0.1353037,46.0,1.5229788165945175,8.229109471417093,2.1363499374218033e-10,0.3525021288302516,318.08298789143925,-3.4057275868328087,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-230MX,CSI Solar Co Ltd,Mono-c-Si,0,230.0,202.9,1.5487849999999999,1.615,0.959,60.0,8.22,37.1,7.7,29.9,0.0032880000000000006,-0.12985,48.3,1.5742804230320662,8.227502113026095,4.734089863393793e-10,0.33880081163487014,371.2212168689543,7.460225870049575,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-230P,CSI Solar Co Ltd,Multi-c-Si,0,230.0,211.0,1.6085159999999998,1.638,0.982,60.0,8.34,36.8,7.71,29.8,0.0030023999999999997,-0.12769599999999998,43.6,1.4710733857749447,8.361302564892561,1.1049532066208971e-10,0.33712629247099557,131.9856729680889,-3.5842372727422216,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-230PX,CSI Solar Co Ltd,Multi-c-Si,0,230.0,211.0,1.6085159999999998,1.638,0.982,60.0,8.34,36.8,7.71,29.8,0.0030023999999999997,-0.12769599999999998,43.6,1.4710733857749447,8.361302564892561,1.1049532066208971e-10,0.33712629247099557,131.9856729680889,-3.5842372727422216,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-235M,CSI Solar Co Ltd,Mono-c-Si,0,235.0,212.4,1.5487849999999999,1.615,0.959,60.0,8.34,37.2,7.82,30.1,0.00417834,-0.13566840000000002,46.0,1.5298331685857032,8.34826981507607,2.2661101136248644e-10,0.3303983788255845,333.202476222268,-3.0607187973707104,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-235MX,CSI Solar Co Ltd,Mono-c-Si,0,235.0,207.5,1.5487849999999999,1.615,0.959,60.0,8.34,37.2,7.82,30.1,0.003336,-0.1302,48.3,1.5813701380276974,8.346738348605196,5.014761715401211e-10,0.31680618577383757,392.1086000304933,7.832478719585607,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-235P,CSI Solar Co Ltd,Multi-c-Si,0,235.0,213.6,1.5487849999999999,1.615,0.959,60.0,8.46,36.9,7.9,29.8,0.005389020000000001,-0.1348326,44.1,1.5659389979084957,8.470249783794417,4.862728179287008e-10,0.3191720426515872,263.4393198755906,2.628585126830822,-0.4538,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-235PX,CSI Solar Co Ltd,Multi-c-Si,0,235.0,215.7,1.6085159999999998,1.638,0.982,60.0,8.46,36.9,7.9,29.8,0.0030456,-0.128043,43.6,1.4649893053508602,8.4737649615126,9.552530351027751e-11,0.3457100913809625,212.47480421328015,-4.849992942860053,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-240M,CSI Solar Co Ltd,Mono-c-Si,0,240.0,217.1,1.5487849999999999,1.615,0.959,60.0,8.46,37.3,7.95,30.2,0.00423846,-0.13603310000000002,46.0,1.5327104075952722,8.46662507597432,2.2598538646093355e-10,0.3238819614153,413.58636881805234,-3.2008010099614888,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-240MX,CSI Solar Co Ltd,Mono-c-Si,0,240.0,212.0,1.5487849999999999,1.615,0.959,60.0,8.46,37.3,7.95,30.2,0.0033840000000000003,-0.13055,48.3,1.5843283152325558,8.46515155706742,5.002959720130648e-10,0.3104906670017884,509.89479379297006,7.67982280386086,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-240P,CSI Solar Co Ltd,Multi-c-Si,0,240.0,218.3,1.5487849999999999,1.615,0.959,60.0,8.59,37.0,8.03,29.9,0.0054718300000000004,-0.135198,44.1,1.569865665273217,8.59951102993792,4.9199362741968e-10,0.31243500827862414,282.17946602859513,2.5958646748958696,-0.4538,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-240PX,CSI Solar Co Ltd,Multi-c-Si,0,240.0,218.3,1.5487849999999999,1.615,0.959,60.0,8.59,37.0,8.03,29.9,0.0054718300000000004,-0.135198,44.1,1.569865665273217,8.59951102993792,4.9199362741968e-10,0.31243500827862414,282.17946602859513,2.5958646748958696,-0.4538,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-245M,CSI Solar Co Ltd,Mono-c-Si,0,245.0,223.3,1.5487849999999999,1.615,0.959,60.0,8.61,37.4,8.09,30.3,0.00426195,-0.1277584,44.3,1.5411712828987445,8.61671149714667,2.4633221803471407e-10,0.3153661642733309,404.5748803466104,3.966526047892846,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-245MX,CSI Solar Co Ltd,Mono-c-Si,0,245.0,221.7,1.5487849999999999,1.615,0.959,60.0,8.61,37.4,8.09,30.3,0.00431361,-0.1363978,46.0,1.5374772123485123,8.61682168138265,2.323494498496529e-10,0.31631414700803845,399.23665523925104,-3.120626617967843,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-245P,CSI Solar Co Ltd,Multi-c-Si,0,245.0,224.9,1.5487849999999999,1.615,0.959,60.0,8.74,37.1,8.17,30.0,0.0034086000000000003,-0.11167099999999999,43.6,1.4804248286144246,8.752907153635503,1.1226125165894398e-10,0.32908533068656826,222.83812691597925,10.863833119655414,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-245PX,CSI Solar Co Ltd,Multi-c-Si,0,245.0,224.9,1.5487849999999999,1.615,0.959,60.0,8.74,37.1,8.17,30.0,0.0034086000000000003,-0.11167099999999999,43.6,1.4804248286144246,8.752907153635503,1.1226125165894398e-10,0.32908533068656826,222.83812691597925,10.863833119655414,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-250M,CSI Solar Co Ltd,Mono-c-Si,0,250.0,228.0,1.5487849999999999,1.615,0.959,60.0,8.74,37.5,8.22,30.4,0.004326300000000001,-0.1281,44.3,1.545067772013646,8.746035026715823,2.4943766249309195e-10,0.308842831072878,447.2700783658798,3.9427378152875483,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-250MX,CSI Solar Co Ltd,Mono-c-Si,0,250.0,226.4,1.5487849999999999,1.615,0.959,60.0,8.74,37.5,8.22,30.4,0.00437874,-0.1367625,46.0,1.5413630630803128,8.746143906430442,2.352717547447411e-10,0.30977877095809203,440.6751608342181,-3.142973589210442,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-250P,CSI Solar Co Ltd,Multi-c-Si,0,250.0,229.6,1.5487849999999999,1.615,0.959,60.0,8.87,37.2,8.3,30.1,0.0034592999999999994,-0.11197200000000002,43.6,1.4841620790471217,8.882152772319193,1.1357481671840312e-10,0.32246015506735454,235.35549399262013,10.832036021618057,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-250PX,CSI Solar Co Ltd,Multi-c-Si,0,250.0,229.6,1.5487849999999999,1.615,0.959,60.0,8.87,37.2,8.3,30.1,0.0034592999999999994,-0.11197200000000002,43.6,1.4841620790471217,8.882152772319193,1.1357481671840312e-10,0.32246015506735454,235.35549399262013,10.832036021618057,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-250P,CSI Solar Co Ltd,Multi-c-Si,0,250.0,231.9,1.55,,,54.0,9.55,34.2,8.75,28.6,0.005348000000000001,-0.0963756,44.2,1.3353921919400416,9.57180585336069,6.868457547683515e-11,0.16772305547776575,73.45528483805522,12.958671774595164,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-255M,CSI Solar Co Ltd,Mono-c-Si,0,255.0,232.7,1.5487849999999999,1.615,0.959,60.0,8.87,37.7,8.35,30.5,0.004390649999999999,-0.12878320000000001,44.3,1.5507469662621596,8.87537490759836,2.435264209922155e-10,0.3147533696165007,519.4253065052952,3.6145692237160656,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-255MX,CSI Solar Co Ltd,Mono-c-Si,0,255.0,231.0,1.5487849999999999,1.615,0.959,60.0,8.87,37.7,8.35,30.5,0.004443869999999999,-0.13749190000000003,46.0,1.5469969494660063,8.87548688976034,2.295590203115762e-10,0.31568435756277097,510.32934394638573,-3.4532907637769354,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-255P,CSI Solar Co Ltd,Multi-c-Si,0,255.0,234.3,1.5487849999999999,1.615,0.959,60.0,9.0,37.4,8.43,30.2,0.0035099999999999997,-0.112574,43.6,1.489711206905821,9.011620252071145,1.1077859792910001e-10,0.3281277360539606,254.13818761223968,10.475846342867026,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-255PX,CSI Solar Co Ltd,Multi-c-Si,0,255.0,234.3,1.5487849999999999,1.615,0.959,60.0,9.0,37.4,8.43,30.2,0.0035099999999999997,-0.112574,43.6,1.489711206905821,9.011620252071145,1.1077859792910001e-10,0.3281277360539606,254.13818761223968,10.475846342867026,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-255P,CSI Solar Co Ltd,Multi-c-Si,0,255.0,236.6,1.55,,,54.0,9.62,34.4,8.86,28.8,0.0053872,-0.09693919999999999,44.2,1.3403130799331466,9.638802592666549,6.587179611759504e-11,0.16400903620495044,83.91220129753415,12.491074003826483,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-255P,CSI Solar Co Ltd,Multi-c-Si,0,255.0,226.3,1.851829,1.931,0.959,72.0,7.95,43.7,7.33,34.8,0.00477,-0.17043000000000003,44.8,1.9892814445207032,7.967090924447446,2.23419317783021e-09,0.44307771060944723,206.1017812910848,9.41504907991381,-0.53,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-260M,CSI Solar Co Ltd,Mono-c-Si,0,260.0,237.3,1.5487849999999999,1.615,0.959,60.0,8.99,37.8,8.48,30.7,0.0044500500000000005,-0.1291248,44.3,1.5566745731137253,8.993829673982825,2.5440798127312247e-10,0.29494598049467735,692.3735990835845,3.8618699384246806,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-260MX,CSI Solar Co Ltd,Mono-c-Si,0,260.0,235.7,1.5487849999999999,1.615,0.959,60.0,8.99,37.8,8.48,30.7,0.00450399,-0.13785660000000002,46.0,1.5529371642070695,8.993932427051766,2.399345491257184e-10,0.29586197170360634,676.3761483751954,-3.219002589495809,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-260P,CSI Solar Co Ltd,Multi-c-Si,0,260.0,239.1,1.5487849999999999,1.615,0.959,60.0,9.12,37.5,8.56,30.4,0.0035567999999999997,-0.112875,43.6,1.495362113260368,9.12968094124976,1.1567389723045961e-10,0.3083946993358069,290.52545331158365,10.73589196287025,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-260PX,CSI Solar Co Ltd,Multi-c-Si,0,260.0,239.1,1.5487849999999999,1.615,0.959,60.0,9.12,37.5,8.56,30.4,0.0035567999999999997,-0.112875,43.6,1.495362113260368,9.12968094124976,1.1567389723045961e-10,0.3083946993358069,290.52545331158365,10.73589196287025,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-260P,CSI Solar Co Ltd,Multi-c-Si,0,260.0,241.4,1.55,,,54.0,9.69,34.6,8.97,29.0,0.0054264000000000005,-0.0975028,44.2,1.3453010522921427,9.705920847114292,6.326914141023575e-11,0.1603564978205244,97.5987310630008,12.039549223184599,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-260P,CSI Solar Co Ltd,Multi-c-Si,0,260.0,230.8,1.851829,1.931,0.959,72.0,8.04,43.8,7.45,34.9,0.004824,-0.17082,44.8,1.9888843031148296,8.053088880406378,2.1520541734882674e-09,0.43632903344064156,268.0204959198876,8.964422101008486,-0.53,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-265M,CSI Solar Co Ltd,Mono-c-Si,0,265.0,242.0,1.5487849999999999,1.615,0.959,60.0,9.11,37.9,8.61,30.9,0.00450945,-0.1294664,44.3,1.562617700240637,9.112439187880735,2.657196368165883e-10,0.2757397047806271,1029.846658443944,4.109588366621471,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-265MX,CSI Solar Co Ltd,Mono-c-Si,0,265.0,240.4,1.5487849999999999,1.615,0.959,60.0,9.11,37.9,8.61,30.9,0.00456411,-0.13822130000000002,46.0,1.5588929597930778,9.112532860291525,2.507254162530913e-10,0.2766410819847532,995.0020297843593,-2.984321514382376,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-265P,CSI Solar Co Ltd,Multi-c-Si,0,265.0,243.8,1.5487849999999999,1.615,0.959,60.0,9.23,37.7,8.66,30.6,0.0035997000000000004,-0.11347700000000001,43.6,1.5046460459658768,9.24004411717874,1.1958068644750216e-10,0.30121543136563533,276.800694301625,10.92713337860716,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-265PX,CSI Solar Co Ltd,Multi-c-Si,0,265.0,243.8,1.5487849999999999,1.615,0.959,60.0,9.23,37.7,8.66,30.6,0.0035997000000000004,-0.11347700000000001,43.6,1.5046460459658768,9.24004411717874,1.1958068644750216e-10,0.30121543136563533,276.800694301625,10.92713337860716,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-265P,CSI Solar Co Ltd,Multi-c-Si,0,265.0,246.1,1.55,,,54.0,9.76,34.8,9.08,29.2,0.0054656,-0.0980664,44.2,1.3503527140332643,9.7731575104474,6.085636851712147e-11,0.1567647373984768,116.28520897036024,11.603288685837734,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-265P,CSI Solar Co Ltd,Multi-c-Si,0,265.0,235.4,1.851829,1.931,0.959,72.0,8.1,43.9,7.55,35.1,0.00486,-0.17121,44.8,1.991033048488469,8.10815725480089,2.125634139096103e-09,0.415468471767592,412.55282325420876,8.770701919475794,-0.53,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-270M,CSI Solar Co Ltd,Mono-c-Si,0,270.0,244.9,1.5487849999999999,1.615,0.959,60.0,9.19,38.2,8.67,31.1,0.0038598,-0.137138,46.4,1.5496943205749103,9.19452361825594,1.799121972942116e-10,0.287540338030384,584.1554327024759,-3.9971877175971153,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-270MX,CSI Solar Co Ltd,Mono-c-Si,0,270.0,244.9,1.5487849999999999,1.615,0.959,60.0,9.19,38.2,8.67,31.1,0.0038598,-0.137138,46.4,1.5496943205749103,9.19452361825594,1.799121972942116e-10,0.287540338030384,584.1554327024759,-3.9971877175971153,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-270P,CSI Solar Co Ltd,Multi-c-Si,0,270.0,247.1,1.5928319999999998,1.632,0.976,60.0,9.32,37.9,8.75,30.8,-0.00441768,-0.11639089999999999,45.8,1.3237443832130642,9.336694078405712,3.3620723778833535e-12,0.3416677132814834,190.74686346547495,-17.43254599860907,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-270P,CSI Solar Co Ltd,Multi-c-Si,0,270.0,250.9,1.55,,,54.0,9.83,35.0,9.19,29.4,0.0055048,-0.09863000000000001,44.2,1.3554648964829132,9.840509536139447,5.861558699822922e-11,0.15323298236593452,143.32509189621672,11.181536638584808,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-270P,CSI Solar Co Ltd,Multi-c-Si,0,270.0,240.0,1.851829,1.931,0.959,72.0,8.19,44.1,7.65,35.3,0.004914,-0.17199,44.8,1.9991384942774302,8.19653297907941,2.1315859760229143e-09,0.40670386941438874,509.86071047710345,8.69089078673505,-0.53,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-275M,CSI Solar Co Ltd,Mono-c-Si,0,275.0,249.5,1.5487849999999999,1.615,0.959,60.0,9.31,38.3,8.8,31.3,0.0039102,-0.137497,46.4,1.5555458001173967,9.313119281148555,1.8786524379553767e-10,0.26889867879020496,802.5718694017545,-3.768434226174815,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-275MX,CSI Solar Co Ltd,Mono-c-Si,0,275.0,249.5,1.5487849999999999,1.615,0.959,60.0,9.31,38.3,8.8,31.3,0.0039102,-0.137497,46.4,1.5555458001173967,9.313119281148555,1.8786524379553767e-10,0.26889867879020496,802.5718694017545,-3.768434226174815,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-275P,CSI Solar Co Ltd,Multi-c-Si,0,275.0,251.8,1.5928319999999998,1.632,0.976,60.0,9.45,38.0,8.88,31.0,-0.004479299999999999,-0.116698,45.8,1.3289039512325616,9.465565640564774,3.5359219936682483e-12,0.32255181093632007,195.8232687081107,-17.191259501570094,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-275P,CSI Solar Co Ltd,Multi-c-Si,0,275.0,255.6,1.55,,,54.0,9.9,35.2,9.3,29.6,0.005544,-0.0991936,44.2,1.3606346378937888,9.907973941776792,5.653094190073739e-11,0.14976040312668068,185.9341406291951,10.773586412922798,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-275P,CSI Solar Co Ltd,Multi-c-Si,0,275.0,244.6,1.851829,1.931,0.959,72.0,8.31,44.1,7.76,35.5,0.004986,-0.17199,44.8,2.0064564428286147,8.316723829910478,2.34156511766568e-09,0.36986175560570195,457.1137434164649,9.402229863128339,-0.53,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-280M,CSI Solar Co Ltd,Mono-c-Si,0,280.0,254.2,1.5487849999999999,1.615,0.959,60.0,9.43,38.5,8.89,31.5,0.0039606,-0.138215,46.4,1.5668765536375107,9.435180517464874,1.9947553208781538e-10,0.2618252240370851,476.59566397715673,-3.393149271526495,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-280MX,CSI Solar Co Ltd,Mono-c-Si,0,280.0,254.2,1.5487849999999999,1.615,0.959,60.0,9.43,38.5,8.89,31.5,0.0039606,-0.138215,46.4,1.5668765536375107,9.435180517464874,1.9947553208781538e-10,0.2618252240370851,476.59566397715673,-3.393149271526495,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-280M,CSI Solar Co Ltd,Mono-c-Si,0,280.0,259.5,1.55,,,54.0,9.96,36.5,9.34,30.0,0.0033366000000000003,-0.101543,44.7,1.3750144556677548,9.973404150744143,2.8946009070761464e-11,0.24467399411713836,181.80585016182948,6.549801380209356,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-280P,CSI Solar Co Ltd,Multi-c-Si,0,280.0,260.4,1.55,,,54.0,9.97,35.4,9.4,29.8,0.005583200000000001,-0.09975719999999999,44.2,1.3665947879659361,9.976070916448801,5.528590779752939e-11,0.1461871496661008,240.07674030764497,10.496576794401935,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-280P,CSI Solar Co Ltd,Multi-c-Si,0,280.0,249.1,1.851829,1.931,0.959,72.0,8.42,44.2,7.86,35.6,0.005052,-0.17238000000000003,44.8,2.0120851876022714,8.427052876712024,2.3995220312573403e-09,0.36282926987154623,433.160290306149,9.5048010057923,-0.53,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-285M,CSI Solar Co Ltd,Mono-c-Si,0,285.0,258.9,1.5487849999999999,1.615,0.959,60.0,9.51,38.6,8.98,31.7,0.003994200000000001,-0.138574,46.4,1.5729349788845872,9.513975847558617,2.0783085658147617e-10,0.24501874984325694,586.0709422725247,-3.1440367377360188,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6P-285MX,CSI Solar Co Ltd,Mono-c-Si,0,285.0,258.9,1.5487849999999999,1.615,0.959,60.0,9.51,38.6,8.98,31.7,0.003994200000000001,-0.138574,46.4,1.5729349788845872,9.513975847558617,2.0783085658147617e-10,0.24501874984325694,586.0709422725247,-3.1440367377360188,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-285M,CSI Solar Co Ltd,Mono-c-Si,0,285.0,264.2,1.55,,,54.0,10.02,36.7,9.41,30.3,0.0033567000000000002,-0.10209940000000002,44.7,1.3847855928047723,10.031681667704223,3.0434703665495585e-11,0.22794745121838564,195.52289483801746,6.925309365095138,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-285P,CSI Solar Co Ltd,Multi-c-Si,0,285.0,261.5,1.851829,1.931,0.959,72.0,8.53,44.3,7.96,35.8,0.0033267,-0.133343,43.6,1.7686820811907524,8.544106355206813,1.1083137751264341e-10,0.4058236917281701,245.39834741429647,10.973125013425948,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-290MS,CSI Solar Co Ltd,Mono-c-Si,0,290.0,269.5,1.603,,,3.0,9.65,38.9,9.04,32.1,0.00346435,-0.1135102,43.3,1.4994999069036354,9.662163354528902,5.123220862113638e-11,0.2454890361583974,194.76282071120806,6.581242716828261,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-290M,CSI Solar Co Ltd,Mono-c-Si,0,290.0,269.0,1.55,,,54.0,10.08,36.9,9.48,30.6,0.0033768,-0.1026558,44.7,1.3945406297412868,10.090093008570292,3.196951108547624e-11,0.21148440172037478,211.2118283545933,7.294120022467968,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-290P,CSI Solar Co Ltd,Multi-c-Si,0,290.0,266.2,1.851829,1.931,0.959,72.0,8.64,44.4,8.08,35.9,0.0033696000000000004,-0.13364399999999999,43.6,1.7712515243227482,8.652402505110981,1.102990115048592e-10,0.398839352885113,277.84485165047994,10.807446559653364,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-295MS,CSI Solar Co Ltd,Mono-c-Si,0,295.0,274.3,1.603,,,3.0,9.73,39.1,9.14,32.3,0.0034930700000000005,-0.11409380000000001,43.3,1.5059852480311833,9.74013358955233,5.0737797308449613e-11,0.24052301527451647,230.94373126526736,6.416298234326642,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-295M,CSI Solar Co Ltd,Mono-c-Si,0,295.0,273.7,1.55,,,54.0,10.14,37.1,9.55,30.9,0.0033969000000000004,-0.1032122,44.7,1.4042800179920893,10.148634415672637,3.355073865971217e-11,0.19527851099278004,229.32925635673152,7.656414958261844,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-295P,CSI Solar Co Ltd,Multi-c-Si,0,295.0,270.9,1.851829,1.931,0.959,72.0,8.76,44.5,8.19,36.0,0.0034164,-0.133945,43.6,1.776007685829436,8.77275519504156,1.130046384482462e-10,0.39151492572527896,268.8842403279597,10.901849686241764,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-300MS,CSI Solar Co Ltd,Mono-c-Si,0,300.0,279.0,1.603,,,3.0,9.82,39.3,9.24,32.5,0.0035253800000000003,-0.11467739999999998,43.3,1.5132717630569608,9.828907572950731,5.0937369368580347e-11,0.23532208306219746,259.42676862454624,6.364454381362028,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-300M,CSI Solar Co Ltd,Mono-c-Si,0,300.0,278.5,1.55,,,54.0,10.19,37.3,9.62,31.2,0.00341365,-0.1037686,44.7,1.4133127448641576,10.196700961085519,3.473362058582463e-11,0.17961350644606683,273.1342015685402,7.905758915693441,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-300P,CSI Solar Co Ltd,Multi-c-Si,0,300.0,274.1,1.9012479999999998,1.948,0.976,72.0,8.87,44.6,8.3,36.1,-0.004204379999999999,-0.1369666,45.8,1.5572718844202402,8.88962454616872,3.1603454897159863e-12,0.4426567431154227,200.074197133529,-17.501254413379655,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-300P,CSI Solar Co Ltd,Multi-c-Si,0,300.0,278.3,1.85,,,66.0,9.56,41.6,8.68,34.6,0.0053536,-0.11722880000000001,44.2,1.627475511878204,9.589626940155899,7.149628939821657e-11,0.22719020718857452,73.3095751353527,13.349078481178411,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-305MS,CSI Solar Co Ltd,Mono-c-Si,0,305.0,283.8,1.603,,,3.0,9.9,39.5,9.33,32.7,0.0035541,-0.115261,43.3,1.5206180580926636,9.907759775167369,5.1131830646175424e-11,0.230454766961473,294.0165226150795,6.321366773277782,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-305M,CSI Solar Co Ltd,Mono-c-Si,0,305.0,283.3,1.55,,,54.0,10.25,37.5,9.69,31.5,0.0034337500000000006,-0.104325,44.7,1.4230192387322973,10.255547276641739,3.638924039669672e-11,0.16390326603699193,302.85284233059485,8.2556181093595,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-305P,CSI Solar Co Ltd,Multi-c-Si,0,305.0,278.8,1.9012479999999998,1.948,0.976,72.0,8.97,44.8,8.41,36.3,-0.00425178,-0.13758079999999998,45.8,1.5636701996113909,8.987754433538798,3.168831448898214e-12,0.43431077581609123,219.42505802792962,-17.566698527300062,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-305P,CSI Solar Co Ltd,Multi-c-Si,0,305.0,283.0,1.85,,,66.0,9.6,41.8,8.77,34.8,0.005376000000000001,-0.11779239999999999,44.2,1.6307467446378272,9.625712454041066,6.733635998587054e-11,0.22396239515491118,83.61858442087663,12.739958397791215,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-310MS,CSI Solar Co Ltd,Mono-c-Si,0,310.0,288.9,1.63,,,66.0,9.37,43.1,8.82,35.2,0.005865619999999999,-0.11869740000000001,45.1,1.6110068868685148,9.38032963502406,2.2221802190661314e-11,0.3378270076604737,306.44248861020986,5.483248412539975,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-310MS,CSI Solar Co Ltd,Mono-c-Si,0,310.0,288.6,1.603,,,3.0,9.98,39.7,9.43,32.9,0.00358282,-0.1158446,43.3,1.5271614120926453,9.98591203405568,5.0692011275466155e-11,0.22577938773988224,381.1341806599013,6.167985627924415,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-310P-AG,CSI Solar Co Ltd,Multi-c-Si,0,310.0,285.4,1.92,,,72.0,8.88,44.7,8.34,37.2,0.0032589600000000004,-0.1390617,44.6,1.743557441545966,8.888148849000423,6.41063079499235e-11,0.2593149946518737,282.58189612109044,2.420751935385294,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6PH-310M,CSI Solar Co Ltd,Mono-c-Si,0,310.0,288.0,1.55,,,54.0,10.31,37.7,9.75,31.8,0.0034538500000000005,-0.10488140000000001,44.7,1.4334485484780082,10.315026266873696,3.856410838255862e-11,0.14827887122752192,304.1532059201024,8.71201642332204,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-310P,CSI Solar Co Ltd,Multi-c-Si,0,310.0,285.9,1.74,,,72.0,9.08,44.9,8.52,36.4,0.00325064,-0.1400431,43.9,1.7606234951898716,9.090759845059097,7.521518658348934e-11,0.378182270497401,319.13983343617014,3.293024608448094,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-310P,CSI Solar Co Ltd,Multi-c-Si,0,310.0,283.4,1.9012479999999998,1.948,0.976,72.0,9.08,44.9,8.52,36.4,-0.00430392,-0.1378879,45.8,1.566978224189752,9.097102120965987,3.199867745372667e-12,0.4273872324586605,226.91197696217847,-17.586493764029917,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-310P,CSI Solar Co Ltd,Multi-c-Si,0,310.0,287.8,1.85,,,66.0,9.64,42.0,8.86,35.0,0.005398400000000001,-0.11835599999999999,44.2,1.6341180623616223,9.661916243171559,6.352763268098999e-11,0.22075437457339508,97.10022702094857,12.149715981175966,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-315MS,CSI Solar Co Ltd,Mono-c-Si,0,315.0,293.7,1.63,,,66.0,9.44,43.2,8.91,35.4,0.00590944,-0.1189728,45.1,1.615451793759795,9.447899324258788,2.271599013557047e-11,0.32078177002472447,383.3467088219538,5.598657670703482,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-315MS,CSI Solar Co Ltd,Mono-c-Si,0,315.0,293.3,1.603,,,3.0,10.06,39.9,9.52,33.1,0.0036115400000000003,-0.11642820000000001,43.3,1.5345310194757877,10.064857566578679,5.090422734406117e-11,0.2210914277830843,457.8794347427806,6.129404909463018,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-315PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,315.0,293.8,1.82,,,60.0,10.58,38.6,9.97,31.6,0.0046657800000000004,-0.1044516,43.6,1.4374528850596884,10.59064632859759,2.2731841843231485e-11,0.2606357445263483,259.0119388198169,6.756482873733525,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-315P-AG,CSI Solar Co Ltd,Multi-c-Si,0,315.0,290.2,1.92,,,72.0,8.96,44.9,8.43,37.4,0.003288320000000001,-0.1396839,44.6,1.7506068475024052,8.967137983137144,6.410348312400545e-11,0.25382565557131964,318.61632125006986,2.339829408021938,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-315P,CSI Solar Co Ltd,Multi-c-Si,0,315.0,290.7,1.74,,,72.0,9.18,45.1,8.61,36.6,0.0032864399999999994,-0.1406669,43.9,1.7698661840253855,9.191191088637845,7.754362895240341e-11,0.3705820935070665,303.98684757462223,3.4574994884787773,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-315P,CSI Solar Co Ltd,Multi-c-Si,0,315.0,288.1,1.9012479999999998,1.948,0.976,72.0,9.18,45.1,8.61,36.6,-0.00435132,-0.1385021,45.8,1.5749430691942676,9.197599246974766,3.2915271295619344e-12,0.4196388862699022,218.8891938993979,-17.468905593621795,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-315P,CSI Solar Co Ltd,Multi-c-Si,0,315.0,292.5,1.85,,,66.0,9.68,42.2,8.95,35.2,0.0054208,-0.11891960000000001,44.2,1.6375847206339713,9.698236436084072,6.00333198921452e-11,0.21756778027783497,115.48616853722181,11.57747302026527,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-320MS,CSI Solar Co Ltd,Mono-c-Si,0,320.0,298.4,1.63,,,66.0,9.51,43.3,9.0,35.6,0.00595326,-0.11924819999999998,45.1,1.61990626107435,9.515674125962155,2.3220862596821e-11,0.30408096026764897,509.64853634203075,5.714588421910982,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-320MS,CSI Solar Co Ltd,Mono-c-Si,0,320.0,298.1,1.6,,,60.0,10.14,40.1,9.61,33.3,0.004826640000000001,-0.11087650000000002,45.5,1.4855382521479867,10.14520272650326,1.9021248610364392e-11,0.2293356730263025,446.9702097937284,3.2596663322993,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-320P,CSI Solar Co Ltd,Multi-c-Si,0,320.0,297.8,1.79,,,60.0,10.66,38.8,10.07,31.8,0.00497822,-0.10425559999999999,44.7,1.4368010004273613,10.668596409300099,1.9735793047757546e-11,0.25747168872351495,319.2784501481517,6.184055508803101,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-320PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,320.0,298.5,1.82,,,60.0,10.66,38.8,10.07,31.8,0.00470106,-0.1049928,43.6,1.4440587878941245,10.668344096739359,2.2610237323353304e-11,0.25590063678535085,326.9258393048742,6.635120280027167,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-320P,CSI Solar Co Ltd,Multi-c-Si,0,320.0,295.5,1.92,,,72.0,9.04,45.1,8.52,37.6,0.00452904,-0.1318724,44.6,1.756034353100101,9.046192757371514,6.259451775242222e-11,0.2488636058799368,363.28357792538054,8.456247629418025,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-320P-AG,CSI Solar Co Ltd,Multi-c-Si,0,320.0,294.9,1.92,,,72.0,9.04,45.1,8.52,37.6,0.00331768,-0.1403061,44.6,1.7576752751782698,9.046160461368423,6.411639941649817e-11,0.24844430946672366,364.5727754921045,2.2617427522690856,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-320P,CSI Solar Co Ltd,Multi-c-Si,0,320.0,295.4,1.74,,,72.0,9.26,45.3,8.69,36.8,0.0033150799999999998,-0.1412907,43.9,1.7781963242787266,9.270708045880266,7.880543423522403e-11,0.3639630366933118,314.7444358864538,3.5177676652368275,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-320P,CSI Solar Co Ltd,Multi-c-Si,0,320.0,292.8,1.9012479999999998,1.948,0.976,72.0,9.26,45.3,8.69,36.8,0.00438924,-0.13911629999999997,45.8,1.7789659439798147,9.270685642162231,7.968055048410264e-11,0.3637751725878961,315.24151842394684,5.091188078343665,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-320P,CSI Solar Co Ltd,Multi-c-Si,0,320.0,297.3,1.85,,,66.0,9.72,42.4,9.04,35.4,0.0054432000000000005,-0.1194832,44.2,1.6411422706281475,9.734671090844413,5.6821154488080355e-11,0.2144040396833318,142.0485571583046,11.022405257463182,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-325MS,CSI Solar Co Ltd,Mono-c-Si,0,325.0,303.2,1.63,,,66.0,9.58,43.4,9.09,35.8,0.00599708,-0.1195236,45.1,1.624369896217538,9.583648382697367,2.373652069359187e-11,0.28771431272409875,755.4863139233262,5.831000767079814,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-325MS,CSI Solar Co Ltd,Mono-c-Si,0,325.0,302.9,1.6,,,60.0,10.22,40.3,9.71,33.5,0.004864720000000001,-0.1114295,45.5,1.4919293861203304,10.22341626819064,1.8874688668874112e-11,0.22483692770355007,672.6149894832322,3.1191721183983865,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-325P,CSI Solar Co Ltd,Multi-c-Si,0,325.0,302.5,1.79,,,60.0,10.74,39.0,10.16,32.0,0.00501558,-0.104793,44.7,1.444064905181792,10.747276417742313,1.9861916837187253e-11,0.25279757844568307,373.12948896296285,6.168949836077033,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-325PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,325.0,303.3,1.82,,,60.0,10.74,39.0,10.16,32.0,0.00473634,-0.105534,43.6,1.4513577892546026,10.747033461454095,2.275436997724899e-11,0.2512320723474535,383.6279649946093,6.619805639434894,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-325P,CSI Solar Co Ltd,Multi-c-Si,0,325.0,300.3,1.92,,,72.0,9.12,45.3,8.6,37.8,0.004569119999999999,-0.1324572,44.6,1.7641687435470386,9.125878446310214,6.350293829976342e-11,0.24338440180687132,377.59395184617864,8.503344174991303,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-325P-AG,CSI Solar Co Ltd,Multi-c-Si,0,325.0,299.6,1.92,,,72.0,9.12,45.3,8.6,37.8,0.00334704,-0.14092829999999998,44.6,1.7658202240359198,9.125846676119476,6.504939922255893e-11,0.2429661155504387,378.9932912587812,2.306272349955828,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-325P,CSI Solar Co Ltd,Multi-c-Si,0,325.0,300.1,1.74,,,72.0,9.34,45.5,8.78,37.0,0.0033437199999999997,-0.1419145,43.9,1.7854985761158138,9.349253228460334,7.901686095750502e-11,0.35751058937949104,360.86313824062063,3.462228565437031,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-325P,CSI Solar Co Ltd,Multi-c-Si,0,325.0,297.5,1.9012479999999998,1.948,0.976,72.0,9.34,45.5,8.78,37.0,0.004427159999999999,-0.1397305,45.8,1.7862761331314365,9.349231475637973,7.990005338051212e-11,0.3573226559605619,361.52332471810234,5.035538752904836,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-325P,CSI Solar Co Ltd,Multi-c-Si,0,325.0,302.0,1.85,,,66.0,9.76,42.6,9.13,35.6,0.0054656,-0.12004680000000001,44.2,1.6447865364480274,9.771218211610925,5.3862759166287044e-11,0.21126439416341317,183.80295080709337,10.483738302069812,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-330MS,CSI Solar Co Ltd,Mono-c-Si,0,330.0,308.0,1.63,,,66.0,9.65,43.5,9.18,36.0,0.0060409,-0.11979899999999999,45.1,1.6288423433816726,9.651816675112205,2.4263072895117378e-11,0.2716719696102807,1443.0944758705568,5.9478438197482815,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-330MS,CSI Solar Co Ltd,Mono-c-Si,0,330.0,307.7,1.6,,,60.0,10.3,40.5,9.8,33.7,0.0049028000000000006,-0.11198250000000001,45.5,1.499070378169371,10.302420363746217,1.896234656649425e-11,0.22034499587233947,937.691089019372,3.0871012170506495,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-330P,CSI Solar Co Ltd,Multi-c-Si,0,330.0,307.3,1.79,,,60.0,10.82,39.2,10.24,32.2,0.00505294,-0.1053304,44.7,1.452003652648051,10.826903543042576,2.021705140191878e-11,0.2481822415565801,388.97880105928704,6.256297065677903,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-330PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,330.0,308.1,1.82,,,60.0,10.82,39.2,10.24,32.2,0.00477162,-0.10607520000000001,43.6,1.4593383758021414,10.826664351493735,2.3160807798867485e-11,0.246618886629169,400.4015100747087,6.707240150229374,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-330P,CSI Solar Co Ltd,Multi-c-Si,0,330.0,305.0,1.92,,,72.0,9.2,45.5,8.69,38.0,0.0046092,-0.133042,44.6,1.7712683505031535,9.204952763402288,6.35432954856121e-11,0.23820487593583528,442.4772090565785,8.425885614808829,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-330P-AG,CSI Solar Co Ltd,Multi-c-Si,0,330.0,304.3,1.92,,,72.0,9.2,45.5,8.69,38.0,0.0033764000000000003,-0.1415505,44.6,1.7729150378382792,9.204922838561288,6.50805580869352e-11,0.2377920151084212,444.39535739604054,2.2319300835085003,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-330P,CSI Solar Co Ltd,Multi-c-Si,0,330.0,304.9,1.74,,,72.0,9.45,45.6,8.88,37.2,0.0033831,-0.1422264,43.9,1.7928957158120455,9.459483562412222,8.392548192870507e-11,0.33851759924422686,337.31959715956674,3.869618827768194,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6X-330P,CSI Solar Co Ltd,Multi-c-Si,0,330.0,302.2,1.9012479999999998,1.948,0.976,72.0,9.45,45.6,8.88,37.2,0.004479299999999999,-0.14003759999999998,45.8,1.7936788879672347,9.459462082159488,8.486458716337504e-11,0.3383299663883059,337.897966853236,5.450055174912006,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-330P,CSI Solar Co Ltd,Multi-c-Si,0,330.0,306.8,1.85,,,66.0,9.83,42.8,9.22,35.8,0.0055048,-0.12061039999999999,44.2,1.6510692064168513,9.839620620765618,5.3200400583295675e-11,0.20703771736699894,211.54360393122766,10.298969541137593,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-335MS,CSI Solar Co Ltd,Mono-c-Si,0,335.0,312.8,1.63,,,66.0,9.73,43.6,9.27,36.2,0.006090980000000001,-0.12007439999999998,45.1,1.6341261586955032,9.730882910030216,2.512359019216641e-11,0.25559529744344817,2816.7564218082384,6.171865985201797,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3K-335MS,CSI Solar Co Ltd,Mono-c-Si,0,335.0,312.5,1.6,,,60.0,10.39,41.2,9.89,33.9,0.00494564,-0.11391800000000002,45.5,1.516012346762746,10.391752853828304,1.632933189553981e-11,0.2667137977359155,1580.939395291872,1.7667012632797072,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-335P,CSI Solar Co Ltd,Multi-c-Si,0,335.0,312.1,1.79,,,60.0,10.9,39.4,10.34,32.4,0.0050903,-0.1058678,44.7,1.4586070201858987,10.904764216211678,2.011862200503284e-11,0.2436901784355552,557.536198218395,6.141233147393343,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-335PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,335.0,312.8,1.82,,,60.0,10.9,39.4,10.34,32.4,0.0048069,-0.10661640000000001,43.6,1.4659704133665932,10.904539836132003,2.3047811034541033e-11,0.24213540870258277,581.3591745818368,6.591715147225316,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-335P,CSI Solar Co Ltd,Multi-c-Si,0,335.0,309.7,1.92,,,72.0,9.28,45.7,8.77,38.2,0.0046492799999999996,-0.1336268,44.6,1.7794136358292167,9.284668250716564,6.446232279931162e-11,0.23292538289423392,463.0316031926486,8.473970255549489,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-335P-AG,CSI Solar Co Ltd,Multi-c-Si,0,335.0,309.0,1.92,,,72.0,9.28,45.7,8.77,38.2,0.0034057600000000003,-0.1421727,44.6,1.7810710931841212,9.284638849018297,6.602454710568494e-11,0.23251340167768336,465.1422004654992,2.277417173978072,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-335P,CSI Solar Co Ltd,Multi-c-Si,0,335.0,309.6,1.74,,,72.0,9.54,45.8,8.96,37.4,0.00341532,-0.14285019999999998,43.9,1.8021979083970017,9.549923413096044,8.640104216924475e-11,0.33196834424641036,319.142022536593,4.035715528299803,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-335P,CSI Solar Co Ltd,Multi-c-Si,0,335.0,311.5,1.85,,,66.0,9.9,43.0,9.31,36.0,0.005544,-0.12117399999999999,44.2,1.6573768276800935,9.908078670044814,5.25701725706649e-11,0.20288269112589258,248.6224407888563,10.119115396148212,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1H-340MS,CSI Solar Co Ltd,Mono-c-Si,0,340.0,317.6,1.63,,,66.0,9.81,43.7,9.35,36.4,0.00614106,-0.1203498,45.1,1.6402514396782455,9.810748257160084,2.6333046146356027e-11,0.23972699263235775,3142.932902570738,6.5064479528968056,-0.3448,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-340P,CSI Solar Co Ltd,Multi-c-Si,0,340.0,316.9,1.79,,,60.0,10.98,39.6,10.43,32.6,0.00512766,-0.1064052,44.7,1.4658850164236166,10.98356999114648,2.024915092095268e-11,0.23925279291687648,735.8549735642607,6.128569530634932,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-340PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,340.0,317.6,1.82,,,60.0,10.98,39.6,10.43,32.6,0.004842180000000001,-0.1071576,43.6,1.4684772800226669,10.980005514719196,2.1335665549036455e-11,0.23861439219553782,475098.75934797176,5.843416688993093,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-340P,CSI Solar Co Ltd,Multi-c-Si,0,340.0,314.5,1.92,,,72.0,9.36,45.9,8.86,38.4,0.00468936,-0.13421160000000001,44.6,1.7865375801896293,9.363794305568396,6.451909294510976e-11,0.22794193854423217,562.2995970529483,8.400142905038495,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-340P-AG,CSI Solar Co Ltd,Multi-c-Si,0,340.0,313.8,1.92,,,72.0,9.36,45.9,8.86,38.4,0.0034351200000000003,-0.1427949,44.6,1.7881907227622884,9.363766708760071,6.607288154269476e-11,0.2275350981913294,565.4083186982524,2.2065624572434146,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6U-340P,CSI Solar Co Ltd,Multi-c-Si,0,340.0,314.4,1.74,,,72.0,9.62,45.9,9.05,37.6,0.00344396,-0.14316210000000001,43.9,1.8077276180080049,9.628437486105783,8.924427334629209e-11,0.3147874090326955,358.9048887857526,4.231514182690106,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-340P,CSI Solar Co Ltd,Multi-c-Si,0,340.0,316.3,1.85,,,66.0,9.97,43.2,9.4,36.2,0.005583200000000001,-0.12173760000000002,44.2,1.663708502097382,9.976591105600464,5.197022804453347e-11,0.19879762985117283,300.71013541062763,9.943993826707924,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-345MS,CSI Solar Co Ltd,Mono-c-Si,0,345.0,320.6,1.79,,,60.0,11.23,39.8,10.43,34.1,0.00563746,-0.11840499999999998,43.3,1.6113713001095846,11.23689963062034,2.0393814402024089e-10,0.06714118994542669,109.28057136308743,15.267280079169005,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-345P,CSI Solar Co Ltd,Multi-c-Si,0,345.0,321.6,1.79,,,60.0,11.06,39.8,10.52,32.8,0.00516502,-0.10694259999999998,44.7,1.4697373136347993,11.06000583715647,1.919557063313806e-11,0.2355358755495705,446290.6978658402,5.590737790348556,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-345PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,345.0,322.4,1.82,,,60.0,11.06,39.8,10.52,32.8,0.00487746,-0.1076988,43.6,1.4806015176572018,11.062209767024349,2.3347827016559424e-11,0.23334591630054707,1167.9085396389219,6.566778180065364,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-345P,CSI Solar Co Ltd,Multi-c-Si,0,345.0,319.2,1.92,,,72.0,9.44,46.1,8.94,38.6,0.00472944,-0.1347964,44.6,1.794692961269131,9.44353830148738,6.544841854112346e-11,0.222851324017293,594.5554930362965,8.449086379493757,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-345P-AG,CSI Solar Co Ltd,Multi-c-Si,0,345.0,318.5,1.92,,,72.0,9.44,46.1,8.94,38.6,0.0034644800000000003,-0.1434171,44.6,1.796357071297739,9.443511226476682,6.702753989224514e-11,0.22244524472771138,598.0483426663768,2.2528829471180716,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-345PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,345.0,318.7,1.94,,,72.0,9.43,46.4,8.86,39.0,0.00299874,-0.13687999999999997,44.0,1.8239691329290204,9.436974009570127,8.296855785144579e-11,0.20197287717655124,273.1003235611575,9.833739940342856,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-345M,CSI Solar Co Ltd,Mono-c-Si,0,345.0,320.0,1.85,,,66.0,9.94,44.4,9.46,36.5,0.0033299000000000002,-0.1235208,44.7,1.6608712268071049,9.941152856565525,2.436157616822061e-11,0.2980633215732093,2569.920504468278,5.0311983434301215,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-345P,CSI Solar Co Ltd,Multi-c-Si,0,345.0,321.1,1.85,,,66.0,10.04,43.4,9.49,36.4,0.0056224,-0.1223012,44.2,1.670063374174007,10.045156710574084,5.1398853484759144e-11,0.1947808939235575,379.2340466405971,9.773431492283837,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-350MS,CSI Solar Co Ltd,Mono-c-Si,0,350.0,325.4,1.79,,,60.0,11.28,40.0,10.52,33.3,0.00566256,-0.119,43.3,1.5905258122681996,11.294299383672774,1.3169581515445488e-10,0.17554220850932353,138.47562960700878,11.206614408586356,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-350P,CSI Solar Co Ltd,Multi-c-Si,0,350.0,326.4,1.79,,,60.0,11.24,40.2,10.61,33.0,0.00524908,-0.1080174,44.7,1.4903815805983882,11.24970061430917,2.1452768521586092e-11,0.24726912593955724,286.5081447947074,6.45020926370899,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-350MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,350.0,323.2,1.94,,,72.0,9.53,46.6,9.03,38.8,0.0020965999999999997,-0.1336954,44.0,1.8024606200597102,9.533546085056383,5.5984010255669906e-11,0.25265118436361966,678.992707227026,9.42444242007371,-0.4036,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-350MS,CSI Solar Co Ltd,Mono-c-Si,0,350.0,325.3,1.919,,,3.0,9.53,46.6,9.03,38.8,0.00342127,-0.1359788,43.3,1.7945194582983899,9.533687631748254,4.992093398898225e-11,0.2545659656148352,657.8785279739351,6.421408737062843,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-350MS-AG,CSI Solar Co Ltd,Mono-c-Si,0,350.0,322.3,1.92,,,72.0,9.53,46.6,9.03,38.8,0.0033640899999999997,-0.1364914,45.7,1.786683460547989,9.533829084325955,4.453769417244915e-11,0.2564585408939829,638.2857544698901,5.05907123752989,-0.3834,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-350P,CSI Solar Co Ltd,Multi-c-Si,0,350.0,324.0,1.92,,,72.0,9.51,46.6,8.94,39.2,0.0047645100000000004,-0.1362584,44.6,1.8255500071200523,9.516791543366988,7.669011809597746e-11,0.19873457887833967,278.2822374197809,9.811543451834913,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-350P-AG,CSI Solar Co Ltd,Multi-c-Si,0,350.0,323.2,1.92,,,72.0,9.51,46.6,8.94,39.2,0.0034901700000000003,-0.1449726,44.6,1.827400363927882,9.516756350086455,7.870198362257663e-11,0.19828081413124776,279.0930807009411,3.5520432310534575,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-350PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,350.0,323.4,1.94,,,72.0,9.51,46.6,8.94,39.2,0.0030241800000000004,-0.13747,44.0,1.8321144252109052,9.516667131475247,8.404943191418954e-11,0.1971255640015478,281.18001874623087,9.871351477582037,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-350M,CSI Solar Co Ltd,Mono-c-Si,0,350.0,324.7,1.85,,,66.0,10.0,44.6,9.52,36.8,0.0033500000000000005,-0.1240772,44.7,1.669123423900155,10.000006413756626,2.4853145609889526e-11,0.28164244935105565,438990.62168842455,5.143546184496097,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-355MS,CSI Solar Co Ltd,Mono-c-Si,0,355.0,330.1,1.79,,,60.0,11.33,40.2,10.61,33.5,0.00568766,-0.119595,43.3,1.5959138369746662,11.341399343505092,1.2764633243616977e-10,0.1725238215705367,171.47434412602922,10.87122001855351,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-355P,CSI Solar Co Ltd,Multi-c-Si,0,355.0,331.2,1.79,,,60.0,11.31,40.4,10.7,33.2,0.00528177,-0.10855479999999999,44.7,1.4970276696279603,11.317538630820586,2.1343172448435897e-11,0.24315113166575736,364.79294525232706,6.343393727321388,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-355MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,355.0,327.9,1.94,,,72.0,9.61,46.8,9.11,39.0,0.0021141999999999997,-0.13426919999999998,44.0,1.8105942497766945,9.613279448424072,5.6801488731335486e-11,0.2474400750642952,725.0912122533499,9.476557028117531,-0.4036,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-355MS,CSI Solar Co Ltd,Mono-c-Si,0,355.0,330.1,1.919,,,3.0,9.61,46.8,9.11,39.0,0.00344999,-0.1365624,43.3,1.8026194655503256,9.613418225429271,5.065277346614997e-11,0.24934707668294373,701.0144752179191,6.472810490573926,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-355MS-AG,CSI Solar Co Ltd,Mono-c-Si,0,355.0,327.1,1.92,,,72.0,9.61,46.8,9.11,39.0,0.0033923299999999994,-0.13707719999999998,45.7,1.7947472969288316,9.613557005732364,4.5191229107023535e-11,0.25123267856165804,678.7580082790222,5.109934884517011,-0.3834,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-355P,CSI Solar Co Ltd,Multi-c-Si,0,355.0,328.7,1.92,,,72.0,9.59,46.8,9.02,39.4,0.00480459,-0.1368432,44.6,1.833670309474297,9.596490997379867,7.7685831279576e-11,0.1939655760630356,286.57073860640037,9.849678402781654,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-355PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,355.0,328.1,1.94,,,72.0,9.59,46.8,9.02,39.4,0.0030496200000000003,-0.13806,44.0,1.8402631598453345,9.59636888100675,8.51385791528436e-11,0.19236319534087135,289.6526221903714,9.909030543849058,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-355M,CSI Solar Co Ltd,Mono-c-Si,0,355.0,329.5,1.85,,,66.0,10.06,44.8,9.57,37.1,0.0033701000000000004,-0.12463359999999998,44.7,1.6824728991316635,10.061826707079035,2.7364218580729602e-11,0.26447854918763297,1456.5306357506065,5.92303606436086,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-360MS,CSI Solar Co Ltd,Mono-c-Si,0,360.0,334.9,1.79,,,60.0,11.4,40.4,10.69,33.7,0.0057228,-0.12018999999999999,43.3,1.6035832608256275,11.410387710863176,1.280829796339164e-10,0.1688768933598668,185.3340610388565,10.841539527356009,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-360P,CSI Solar Co Ltd,Multi-c-Si,0,360.0,332.7,1.79,,,60.0,11.37,40.6,10.78,33.4,0.00621939,-0.1328432,42.9,1.68120562414872,11.370669862836557,3.693300680427168e-10,0.20408164055885394,3463.998991673313,9.598265358613158,-0.4406,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-360MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,360.0,337.5,1.94,,,72.0,9.69,47.0,9.19,39.2,0.004263599999999999,-0.12925000000000003,43.06,1.7468465993274005,9.694307821378285,1.9857738618117637e-11,0.2594831669989219,583.6806368499292,4.619606562069577,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-360MS,CSI Solar Co Ltd,Mono-c-Si,0,360.0,334.9,1.919,,,3.0,9.69,47.0,9.19,39.2,0.0034787100000000003,-0.13714600000000002,43.3,1.8107218782656789,9.693156974929853,5.139049080006634e-11,0.24421850849804727,749.6028646830721,6.524047213292697,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-360MS-AG,CSI Solar Co Ltd,Mono-c-Si,0,360.0,331.8,1.92,,,72.0,9.69,47.0,9.19,39.2,0.00342057,-0.137663,45.7,1.8028135243224481,9.693293078288928,4.5850024974907363e-11,0.24609726131940013,724.1499588000638,5.160635543840945,-0.3834,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-360P,CSI Solar Co Ltd,Multi-c-Si,0,360.0,333.5,1.92,,,72.0,9.67,47.0,9.1,39.6,0.004844670000000001,-0.137428,44.6,1.8417938588003757,9.67619891954514,7.868899960586959e-11,0.189279450896121,295.2663470253854,9.887856172781605,-0.3811,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-360PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,360.0,332.9,1.94,,,72.0,9.67,47.0,9.1,39.6,0.0030750600000000006,-0.13865,44.0,1.8484152390534279,9.676079098833476,8.62359496128644e-11,0.18768356444301534,298.5475420817006,9.946765290728038,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-360M,CSI Solar Co Ltd,Mono-c-Si,0,360.0,334.2,1.85,,,66.0,10.12,45.0,9.63,37.4,0.0033902000000000003,-0.12519,44.7,1.6890291438548886,10.120006090735773,2.7194107979582686e-11,0.24882837092535415,410483.4795810535,5.808123640037343,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-365MS,CSI Solar Co Ltd,Mono-c-Si,0,365.0,339.7,1.79,,,60.0,11.47,40.6,10.78,33.9,0.0057579400000000005,-0.120785,43.3,1.6104777009687248,11.478812323118166,1.2710942658241713e-10,0.16541403043153022,215.30066077559067,10.709820842798312,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-365P,CSI Solar Co Ltd,Multi-c-Si,0,365.0,340.8,1.79,,,60.0,11.44,40.8,10.87,33.6,0.00534248,-0.1096296,44.7,1.5103822356205046,11.443463241761487,2.113251510903971e-11,0.23531498043793853,777.3074012904879,6.141782905912296,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-365MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,365.0,342.3,1.94,,,72.0,9.77,47.2,9.27,39.4,0.004298799999999999,-0.12980000000000003,43.06,1.7546543124753728,9.77403325948733,2.0145830387822405e-11,0.2543890350630028,616.2214244131663,4.670387293703857,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-365MS,CSI Solar Co Ltd,Mono-c-Si,0,365.0,339.6,1.919,,,3.0,9.77,47.2,9.27,39.4,0.0035074299999999997,-0.1377296,43.3,1.8188266291019233,9.772903728803998,5.213406253842758e-11,0.23917794217648894,804.7475375479855,6.575113412354349,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-365MS-AG,CSI Solar Co Ltd,Mono-c-Si,0,365.0,336.5,1.92,,,72.0,9.77,47.2,9.27,39.4,0.0034488099999999996,-0.1382488,45.7,1.8108820758341513,9.773037150607669,4.651406094080511e-11,0.24104996695684064,775.4170199038464,5.211167772556696,-0.3834,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-365P,CSI Solar Co Ltd,Multi-c-Si,0,365.0,339.7,1.92,,,72.0,9.75,47.2,9.18,39.8,0.0042510000000000004,-0.1386736,43.5,1.839709399900939,9.756098045127937,6.915737154448882e-11,0.1871190100974379,299.1795477500315,8.237560917980648,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-365PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,365.0,337.6,1.94,,,72.0,9.75,47.2,9.18,39.8,0.0031005000000000004,-0.13924,44.0,1.8565705686932592,9.75579762971785,8.734149410668518e-11,0.18308454015040207,307.8972445568889,9.984544476814746,-0.4002,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-365M,CSI Solar Co Ltd,Mono-c-Si,0,365.0,339.0,1.85,,,66.0,10.18,45.2,9.69,37.7,0.0034103000000000002,-0.1257464,44.7,1.7032152264521212,10.1816104650237,3.0281176953473584e-11,0.23180032541013326,1465.2460029663494,6.689812066895402,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-370MS,CSI Solar Co Ltd,Mono-c-Si,0,370.0,344.5,1.79,,,60.0,11.54,40.8,10.86,34.1,0.00579308,-0.12137999999999999,43.3,1.618157923349392,11.547885186369594,1.2756702206325774e-10,0.16187394226181784,236.9031333904815,10.682549574767528,-0.3954,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS3L-370P,CSI Solar Co Ltd,Multi-c-Si,0,370.0,342.2,1.79,,,60.0,11.51,41.0,10.95,33.8,0.00629597,-0.134152,42.9,1.7007437953116904,11.510003694562275,3.9038454143056845e-10,0.19564790838511015,609697.1364344127,9.97790003907592,-0.4406,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-370MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,370.0,347.1,1.94,,,72.0,9.85,47.4,9.35,39.6,0.004334,-0.13035,43.06,1.7624641069461913,9.85376651541802,2.0436181440670825e-11,0.24938162367241287,652.1701786961138,4.720987447533666,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-370MS,CSI Solar Co Ltd,Mono-c-Si,0,370.0,344.4,1.919,,,3.0,9.85,47.4,9.35,39.6,0.0035361500000000005,-0.1383132,43.3,1.8269336531689264,9.852658339502664,5.288346530235418e-11,0.23422313739744802,867.8718351459235,6.626003962514452,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-370MS-AG,CSI Solar Co Ltd,Mono-c-Si,0,370.0,341.3,1.92,,,72.0,9.85,47.4,9.35,39.6,0.0034770499999999998,-0.1388346,45.7,1.8189528870053744,9.852789075199775,4.718331623155115e-11,0.23608855194909317,833.7789335490532,5.261526491748633,-0.3834,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-370P,CSI Solar Co Ltd,Multi-c-Si,0,370.0,344.5,1.92,,,72.0,9.83,47.4,9.26,40.0,0.00428588,-0.1392612,43.5,1.8477934153863234,9.835818955495203,7.004136467658833e-11,0.18258312192247975,308.4388813964767,8.275208482528036,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-370PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,370.0,345.8,1.97,,,72.0,9.83,47.4,9.26,40.0,0.004108939999999999,-0.12527819999999998,44.5,1.7506791616152262,9.837666386288758,1.683760006760274e-11,0.20590235918335412,264.0122861678022,7.378850360293389,-0.3402,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-370M,CSI Solar Co Ltd,Mono-c-Si,0,370.0,343.8,1.85,,,66.0,10.24,45.4,9.74,38.0,0.0034304000000000005,-0.1263028,44.7,1.714438011579411,10.242127293036726,3.220978321920987e-11,0.21564164532589597,1038.0189742232317,7.176053195042346,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-375MS,CSI Solar Co Ltd,Mono-c-Si,0,375.0,349.3,1.79,,,60.0,11.61,41.0,10.94,34.3,0.00582822,-0.121975,43.3,1.6091373278813943,11.610005293016863,9.982188380438599e-11,0.16145874429542437,354167.3950102663,8.413348866412301,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-375P,CSI Solar Co Ltd,Multi-c-Si,0,375.0,347.0,1.79,,,60.0,11.59,41.2,11.03,34.0,0.00633973,-0.13480640000000002,42.9,1.710149252709263,11.590003676751694,3.992922917335558e-10,0.19147889529125878,603761.702182594,10.11677708487214,-0.4406,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-375MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,375.0,350.0,1.97,,,66.0,11.2,43.5,10.36,36.2,0.0058687999999999995,-0.134241,44.9,1.6451123536739038,11.223394109252093,3.5449642842306086e-11,0.21194736033977207,101.4704347193581,-3.521382759745902,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-375MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,375.0,349.9,1.97,,,66.0,11.2,43.5,10.36,36.2,0.0053536,-0.1115775,45.5,1.6018799750326285,11.225242979708284,1.7345183409677168e-11,0.22123676760102223,98.16003623406502,9.759234887192834,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-375MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,375.0,351.9,1.94,,,72.0,9.93,47.6,9.43,39.8,0.004369199999999999,-0.13090000000000002,43.06,1.7702759249075508,9.933507445779703,2.072878268568374e-11,0.2444587423053072,692.0920538000976,4.771402435227003,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-375MS,CSI Solar Co Ltd,Mono-c-Si,0,375.0,349.2,1.919,,,3.0,9.93,47.6,9.43,39.8,0.00356487,-0.13889680000000001,43.3,1.8350428879183938,9.932420663243139,5.363867578099228e-11,0.22935192910779106,940.843294334282,6.676714086092717,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-375MS-AG,CSI Solar Co Ltd,Mono-c-Si,0,375.0,346.0,1.92,,,72.0,9.93,47.6,9.43,39.8,0.00350529,-0.1394204,45.7,1.8270258957053285,9.932548708341262,4.785777013676585e-11,0.23121084814974502,900.8185806588789,5.311706966856625,-0.3834,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-375P,CSI Solar Co Ltd,Multi-c-Si,0,375.0,349.2,1.92,,,72.0,9.91,47.6,9.34,40.2,0.004320760000000001,-0.13984880000000002,43.5,1.8558804124625925,9.915547875116923,7.093175575005756e-11,0.17812407726679752,318.17760931224393,8.312871767779132,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-375PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,375.0,350.6,1.97,,,72.0,9.91,47.6,9.34,40.2,0.00414238,-0.1258068,44.5,1.7583264538655285,9.917363094260013,1.705158473172949e-11,0.20135841936787915,271.0086106769779,7.4162978654983585,-0.3402,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6XH-375M,CSI Solar Co Ltd,Mono-c-Si,0,375.0,348.6,1.85,,,66.0,10.3,45.6,9.8,38.3,0.0034505000000000004,-0.1268592,44.7,1.7247992661713283,10.301968472401935,3.382682711110105e-11,0.19980430900203994,1045.4728334623092,7.549337885018585,-0.3727,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-380MS,CSI Solar Co Ltd,Mono-c-Si,0,380.0,357.0,1.95,,,78.0,9.74,51.5,8.89,42.7,0.0041881999999999996,-0.140389,42.9,1.9355958035765521,9.771457625248097,2.5729058069247532e-11,0.31217226161734574,96.65566976677107,7.912152748085159,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-380MS,CSI Solar Co Ltd,Mono-c-Si,0,380.0,358.5,1.82,,,60.0,11.68,41.2,11.02,34.5,0.00612032,-0.10728480000000001,43.4,1.5024720165981624,11.68969260574338,1.4182044588173554e-11,0.18116333989396985,218.30949030104216,5.843020774525956,-0.3242,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-380MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,380.0,354.7,1.97,,,66.0,11.26,43.7,10.44,36.4,0.00590024,-0.1348582,44.9,1.6514661638749772,11.281456145433692,3.5050043688798915e-11,0.20835387770593172,109.34231788943748,-3.6594069055269047,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-380MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,380.0,354.7,1.97,,,66.0,11.26,43.7,10.44,36.4,0.005382280000000001,-0.11209050000000002,45.5,1.6012243915361513,11.283511184546507,1.5258504111335564e-11,0.21907654053998526,104.92035598936688,8.56654471848295,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-380MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,380.0,356.7,1.94,,,72.0,10.01,47.8,9.5,40.0,0.004404399999999999,-0.13145,43.06,1.7789966855892974,10.013901589462202,2.128746860608442e-11,0.2394820095425204,614.4200910816068,4.932058055203559,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-380MS,CSI Solar Co Ltd,Mono-c-Si,0,380.0,353.9,1.92,,,72.0,10.01,47.8,9.5,40.0,0.00476476,-0.132167,45.5,1.776535407921162,10.013945732306476,2.0508264649126504e-11,0.24005631890272738,609.0032474032616,3.9972597821848574,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-380P,CSI Solar Co Ltd,Multi-c-Si,0,380.0,354.0,1.92,,,72.0,9.99,47.8,9.42,40.4,0.00435564,-0.1404364,43.5,1.8639703064379234,9.99528466021963,7.182850475300275e-11,0.17373994602829426,328.4339999899056,8.350541166579841,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-380PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,380.0,355.4,1.97,,,72.0,9.99,47.8,9.42,40.4,0.00417582,-0.1263354,44.5,1.765976340912483,9.997067625831058,1.7267096776860824e-11,0.19689090743353496,278.3028164813129,7.453753024658954,-0.3402,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-380P,CSI Solar Co Ltd,Multi-c-Si,0,380.0,351.0,2.14,,,72.0,10.58,46.4,10.03,37.9,0.0023381800000000005,-0.12931679999999998,45.2,1.7210598224444638,10.584932540391934,2.057296586699127e-11,0.3232305589952836,693.3098669739077,3.0668668749651533,-0.3768,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-380PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,380.0,354.5,2.17,,,72.0,10.58,46.4,10.03,37.9,0.0046657800000000004,-0.1255584,43.6,1.7210340677499567,10.584933253831595,2.0564652013316097e-11,0.323236131445355,693.2216498779894,5.867462872492369,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-380MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,380.0,357.4,1.95,,,54.0,13.55,36.0,12.69,30.0,0.008075800000000001,-0.09406799999999998,43.6,1.3298224542825117,13.56809076106531,2.317235937069518e-11,0.14637498309113314,109.63502433434427,8.384742534828765,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-385MS,CSI Solar Co Ltd,Mono-c-Si,0,385.0,361.8,1.95,,,78.0,9.78,51.7,8.97,42.9,0.0042054,-0.1409342,42.9,1.9390252052509414,9.807904186707681,2.456528340443161e-11,0.30841874149117454,108.09615536567335,7.453951941784779,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-385MS,CSI Solar Co Ltd,Mono-c-Si,0,385.0,358.9,1.79,,,60.0,11.75,41.4,11.1,34.7,0.005898500000000001,-0.12316499999999998,43.3,1.6280017289835371,11.750004653584483,1.0615680211189385e-10,0.1539536244427524,388741.02123976196,8.84712333526334,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-385MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,385.0,359.5,1.97,,,66.0,11.32,43.9,10.52,36.6,0.005931680000000001,-0.1354754,44.9,1.657833654320234,11.339577786553605,3.466539197553454e-11,0.20481046501655073,118.42270678334347,-3.7946321232403135,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-385MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,385.0,359.5,1.97,,,66.0,11.32,43.9,10.52,36.6,0.00541096,-0.11260350000000001,45.5,1.614393215741494,11.341262056507599,1.6979818187641273e-11,0.21400495253765808,113.93705348307472,9.455401636850569,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-385MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,385.0,361.5,1.94,,,72.0,10.09,48.0,9.58,40.2,0.0044396,-0.132,43.06,1.7868089658261777,10.093646412811042,2.1586031764368633e-11,0.23471942558296846,649.4928379804911,4.981225297003928,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-385MS,CSI Solar Co Ltd,Mono-c-Si,0,385.0,358.7,1.92,,,72.0,10.09,48.0,9.58,40.2,0.004802840000000001,-0.13272,45.5,1.7843378698144305,10.093689729261236,2.079637027460127e-11,0.23529149132410732,643.4322560038696,4.046246211018451,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-385P,CSI Solar Co Ltd,Multi-c-Si,0,385.0,358.8,1.92,,,72.0,10.07,48.0,9.5,40.6,0.00439052,-0.141024,43.5,1.872063018081801,10.075029170572513,7.273157458487512e-11,0.16942886149535524,339.25050745507883,8.388207857374818,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-385PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,385.0,360.1,1.97,,,72.0,10.07,48.0,9.5,40.6,0.00420926,-0.12686399999999998,44.5,1.7735898184483718,10.076780523246711,1.7473728978280127e-11,0.19250713043736453,285.8992946233302,7.4860298038653,-0.3402,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-385P,CSI Solar Co Ltd,Multi-c-Si,0,385.0,355.7,2.14,,,72.0,10.66,46.6,10.11,38.1,0.00235586,-0.1298742,45.2,1.7289858153871436,10.664581892181692,2.090125647459434e-11,0.31800719739033567,739.8595777983461,3.1344177417920167,-0.3768,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-385PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,385.0,359.2,2.17,,,72.0,10.66,46.6,10.11,38.1,0.00470106,-0.1260996,43.6,1.7289640218852886,10.664582485062883,2.0894143803405767e-11,0.31801187902523026,739.7747419641112,5.9378213158043645,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-385MB,CSI Solar Co Ltd,Mono-c-Si,1,385.0,362.1,1.89,,,54.0,13.17,37.0,12.52,30.8,0.00890292,-0.09501599999999999,44.4,1.3540452411083919,13.174394304983933,1.777624870885002e-11,0.15913839128837454,476.9474682348742,8.024482578929113,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-385MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,385.0,362.1,1.89,,,54.0,13.17,37.0,12.52,30.8,0.00890292,-0.09501599999999999,44.4,1.3540452411083919,13.174394304983933,1.777624870885002e-11,0.15913839128837454,476.9474682348742,8.024482578929113,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-385MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,385.0,362.2,1.95,,,54.0,13.63,36.2,12.77,30.2,0.00812348,-0.0945906,43.6,1.3125379759546507,13.6487669635384,1.4006051819513044e-11,0.1477534777496415,107.30984280304213,3.980438638722901,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-390MS,CSI Solar Co Ltd,Mono-c-Si,0,390.0,366.6,1.95,,,78.0,9.82,51.9,9.05,43.1,0.0042226,-0.1414794,42.9,1.9425342042201625,9.844437765539249,2.3482098018770918e-11,0.30469593718652005,122.438121804797,7.008037189527193,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3L-390MS,CSI Solar Co Ltd,Mono-c-Si,0,390.0,368.1,1.82,,,60.0,11.82,41.6,11.18,34.9,0.00619368,-0.10832640000000002,43.4,1.5166583351376717,11.827766295807669,1.4287753814615988e-11,0.17431258892478854,265.29697848604087,5.794282265555317,-0.3242,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS3N-390MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,390.0,364.3,1.97,,,66.0,11.38,44.1,10.6,36.8,0.005963120000000001,-0.1360926,44.9,1.6642144207835,11.397757695246707,3.429498163246449e-11,0.20131612980186958,129.0132263133876,-3.9271415108278496,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-390MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,390.0,364.3,1.97,,,66.0,11.38,44.1,10.6,36.8,0.005439640000000001,-0.11311650000000001,45.5,1.620668353923947,11.399361054626981,1.680724964467651e-11,0.21046459324120773,123.7064366720863,9.308060737163288,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-390MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,390.0,362.1,1.97,,,72.0,10.17,48.2,9.66,40.4,0.00471888,-0.1298508,46.3,1.790844211834938,10.173463423764282,2.0678840984930504e-11,0.23090345662204562,678.0250849059092,6.7040280179613285,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-390MS,CSI Solar Co Ltd,Mono-c-Si,0,390.0,363.5,1.92,,,72.0,10.17,48.2,9.66,40.4,0.00484092,-0.13327300000000003,45.5,1.7921422408194816,10.17344112249406,2.1086627477557482e-11,0.23060518575045844,681.5377197248271,4.095048343842271,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-390P,CSI Solar Co Ltd,Multi-c-Si,0,390.0,363.6,1.92,,,72.0,10.15,48.2,9.56,40.8,0.0044254,-0.1416116,43.5,1.8822025569177094,10.155652272466993,7.553350224583278e-11,0.164681038550994,295.72398361823747,8.656614260276228,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-390P,CSI Solar Co Ltd,Multi-c-Si,0,390.0,360.4,2.14,,,72.0,10.74,46.8,10.19,38.3,0.0023735400000000004,-0.13043159999999998,45.2,1.736912947380576,10.744240205895572,2.1232300357765842e-11,0.3128659776541358,792.4569380356736,3.201524306080134,-0.3768,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-390PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,390.0,364.0,2.17,,,72.0,10.74,46.8,10.19,38.3,0.00473634,-0.1266408,43.6,1.7368949868946337,10.744240685515956,2.1226374556932148e-11,0.3128698080306207,792.377005671303,6.007697864881354,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-390MB,CSI Solar Co Ltd,Mono-c-Si,1,390.0,366.9,1.89,,,54.0,13.25,37.2,12.6,31.0,0.008957,-0.0955296,44.4,1.3618955534815322,13.25412751701155,1.808060419975809e-11,0.15599865255095346,500.7810198632565,8.119896576215291,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-390MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,390.0,366.9,1.89,,,54.0,13.25,37.2,12.6,31.0,0.008957,-0.0955296,44.4,1.3618955534815322,13.25412751701155,1.808060419975809e-11,0.15599865255095346,500.7810198632565,8.119896576215291,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-390MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,390.0,367.0,1.95,,,54.0,13.7,36.4,12.84,30.4,0.0081652,-0.0951132,43.6,1.3239516872804904,13.700003837013472,1.572043154017333e-11,0.14393935063207797,513940.5602152481,4.836678091483501,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-390MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,390.0,367.0,1.95,,,54.0,13.7,36.4,12.84,30.4,0.0081652,-0.0951132,43.6,1.3239516872804904,13.700003837013472,1.572043154017333e-11,0.14393935063207797,513940.5602152481,4.836678091483501,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-395MS,CSI Solar Co Ltd,Mono-c-Si,0,395.0,371.5,1.95,,,78.0,9.86,52.1,9.13,43.3,0.004239799999999999,-0.1420246,42.9,1.946119580831634,9.881057003211023,2.247247328317336e-11,0.3010045156587759,140.94619808320576,6.573915505606564,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-395MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,395.0,369.1,1.97,,,66.0,11.44,44.3,10.68,37.0,0.00599456,-0.1367098,44.9,1.6706080792844973,11.455994573196996,3.39381509294422e-11,0.1978699027360827,141.5249830825209,-4.057014377147636,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-395MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,395.0,369.1,1.97,,,66.0,11.44,44.3,10.68,37.0,0.0054683200000000005,-0.11362950000000001,45.5,1.6269553564667947,11.457517908965727,1.664100815506446e-11,0.2069732613576936,135.1630563899442,9.163651049337266,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-395MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,395.0,366.8,1.97,,,72.0,10.25,48.4,9.73,40.6,0.004756,-0.1303896,46.3,1.7995347842254275,10.253836287837782,2.122098192405711e-11,0.22615096448916902,604.2423086338239,6.863126700231852,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-395MS,CSI Solar Co Ltd,Mono-c-Si,0,395.0,367.0,1.92,,,72.0,10.25,48.4,9.73,40.6,0.0038027500000000006,-0.1300024,46.2,1.7866888853731693,10.25406204082377,1.748390834659418e-11,0.22908795350602185,578.0718410669457,5.639099208666737,-0.3492,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-395P,CSI Solar Co Ltd,Multi-c-Si,0,395.0,368.4,1.92,,,72.0,10.23,48.4,9.64,41.0,0.0044602800000000005,-0.1421992,43.5,1.8902923658758048,10.23539213440551,7.645617113080872e-11,0.16050950057327046,304.51989228103764,8.692383224684281,-0.3816,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-395P,CSI Solar Co Ltd,Multi-c-Si,0,395.0,365.2,2.14,,,72.0,10.82,47.0,10.26,38.5,0.0023912200000000003,-0.13098900000000002,45.2,1.7375352378625502,10.820007029702305,1.934816911257574e-11,0.30935097673962386,476155.52599246457,2.350335577955548,-0.3768,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-395PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,395.0,368.8,2.17,,,72.0,10.82,47.0,10.26,38.5,0.00477162,-0.12718200000000002,43.6,1.7456276239608859,10.824846289230106,2.1804434266123218e-11,0.30779392831652436,687.1918331643813,6.17763894805079,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-395MB,CSI Solar Co Ltd,Mono-c-Si,1,395.0,371.7,1.89,,,54.0,13.33,37.4,12.68,31.2,0.00901108,-0.0960432,44.4,1.3697450505318396,13.33386898616413,1.8386900559085147e-11,0.15289917001085193,526.790710276227,8.214142672691402,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-395MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,395.0,371.7,1.89,,,54.0,13.33,37.4,12.68,31.2,0.00901108,-0.0960432,44.4,1.3697450505318396,13.33386898616413,1.8386900559085147e-11,0.15289917001085193,526.790710276227,8.214142672691402,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-395MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,395.0,371.9,1.95,,,54.0,13.77,36.6,12.91,30.6,0.00820692,-0.0956358,43.6,1.353522910305355,13.786507133051702,2.4307009238451633e-11,0.13760262166263257,114.78602327522727,8.661357329358479,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-395MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,395.0,371.9,1.95,,,54.0,13.77,36.6,12.91,30.6,0.00820692,-0.0956358,43.6,1.353522910305355,13.786507133051702,2.4307009238451633e-11,0.13760262166263257,114.78602327522727,8.661357329358479,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-400MS,CSI Solar Co Ltd,Mono-c-Si,0,400.0,376.3,1.95,,,78.0,9.9,52.3,9.2,43.5,0.0042569999999999995,-0.1425698,42.9,1.950843175405249,9.918485263882358,2.181964545436181e-11,0.29719554524101743,159.16656255641777,6.270511791854118,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-400MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,400.0,373.9,1.97,,,66.0,11.5,44.5,10.76,37.2,0.006026,-0.137327,44.9,1.6770142431781248,11.514287161012465,3.359426752820205e-11,0.19447084163313885,156.53317629198395,-4.184329132828948,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-400MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,400.0,373.9,1.97,,,66.0,11.5,44.5,10.76,37.2,0.005497,-0.11414250000000001,45.5,1.6332538807317643,11.515731331165048,1.6480806324775912e-11,0.2035299852905068,148.78555502443794,9.022086945960849,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-400MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,400.0,371.6,1.97,,,72.0,10.33,48.6,9.81,40.8,0.00479312,-0.1309284,46.3,1.8073308710068081,10.333591031143015,2.151032781458998e-11,0.2216134753336841,637.495775454241,6.911551196746436,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-400MS,CSI Solar Co Ltd,Mono-c-Si,0,400.0,371.8,1.92,,,72.0,10.33,48.6,9.81,40.8,0.0038324300000000004,-0.1305396,46.2,1.7944263125913713,10.333812661002852,1.772217863392226e-11,0.22454121566108376,608.3705801616534,5.6868215023611315,-0.3492,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-400P,CSI Solar Co Ltd,Multi-c-Si,0,400.0,369.9,2.14,,,72.0,10.9,47.2,10.34,38.7,0.0024089000000000003,-0.1315464,45.2,1.7535730770496953,10.904508093037082,2.2149083591727942e-11,0.30280344981159457,732.1405449884248,3.431994502317653,-0.3768,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-400PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,400.0,373.6,2.17,,,72.0,10.9,47.2,10.34,38.7,0.0048069,-0.1277232,43.6,1.7535583631893457,10.90450847934032,2.2144072592619374e-11,0.302806546759088,732.0852998976592,6.2458740905743655,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-400MB,CSI Solar Co Ltd,Mono-c-Si,1,400.0,376.5,1.89,,,54.0,13.41,37.6,12.76,31.4,0.00906516,-0.09655679999999998,44.4,1.3775937447774986,13.413618555909164,1.8695119293828998e-11,0.14983917286625262,555.2887381023232,8.30724502507669,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-400MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,400.0,376.5,1.89,,,54.0,13.41,37.6,12.76,31.4,0.00906516,-0.09655679999999998,44.4,1.3775937447774986,13.413618555909164,1.8695119293828998e-11,0.14983917286625262,555.2887381023232,8.30724502507669,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-400MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,400.0,376.7,1.95,,,54.0,13.85,36.8,12.99,30.8,0.0082546,-0.09615839999999999,43.6,1.3613995404555423,13.865983023239348,2.4691287970925895e-11,0.13468363184510315,116.70935358988376,8.747628443090365,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-400MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,400.0,376.7,1.95,,,54.0,13.85,36.8,12.99,30.8,0.0082546,-0.09615839999999999,43.6,1.3613995404555423,13.865983023239348,2.4691287970925895e-11,0.13468363184510315,116.70935358988376,8.747628443090365,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-405MS,CSI Solar Co Ltd,Mono-c-Si,0,405.0,381.1,1.95,,,78.0,9.94,52.5,9.27,43.7,0.0042742,-0.14311500000000002,42.9,1.9556062277310684,9.955979384876423,2.119962625023756e-11,0.2934272804330189,182.52687468147607,5.973694114435158,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-405MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,405.0,378.7,1.97,,,66.0,11.56,44.7,10.83,37.4,0.006057440000000001,-0.13794420000000002,44.9,1.6842325089494543,11.573265104580866,3.3648283830430145e-11,0.19099779411880682,166.4468230698587,-4.21653407425334,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-405MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,405.0,378.7,1.97,,,66.0,11.56,44.7,10.83,37.4,0.005525680000000001,-0.11465550000000002,45.5,1.6402980782301337,11.574662062767825,1.650896852167143e-11,0.20003727218188527,157.71524856004496,8.985826590115654,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-405MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,405.0,376.4,1.97,,,72.0,10.44,49.3,9.88,41.0,0.004844159999999999,-0.1328142,46.3,1.8277149905929626,10.446377579617081,1.994243140323188e-11,0.2670130783104469,437.0963180828191,6.178285741921276,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-405MS,CSI Solar Co Ltd,Mono-c-Si,0,405.0,376.6,1.92,,,72.0,10.44,49.3,9.88,41.0,0.00387324,-0.1324198,46.2,1.8147084396181556,10.446661769175392,1.6431270097488335e-11,0.2699254223215226,423.0139711862269,4.9633240956448335,-0.3492,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-405P,CSI Solar Co Ltd,Multi-c-Si,0,405.0,374.7,2.14,,,72.0,10.98,47.4,10.42,38.9,0.0024265800000000002,-0.1321038,45.2,1.7615013654438287,10.984179026000426,2.249031509699854e-11,0.2978935235384343,782.6873973120636,3.497127105081902,-0.3768,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-405PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,405.0,378.3,2.17,,,72.0,10.98,47.4,10.42,38.9,0.004842180000000001,-0.1282644,43.6,1.7614900762214516,10.984179317733219,2.2486429531366833e-11,0.29789588439113623,782.6389654459734,6.313644775604126,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-405MB,CSI Solar Co Ltd,Mono-c-Si,1,405.0,381.3,1.89,,,54.0,13.49,37.8,12.84,31.6,0.009119239999999999,-0.09707039999999999,44.4,1.3854416519227006,13.493376073672197,1.9005243140793434e-11,0.14681791055328505,586.650008603087,8.399224481475507,-0.3205,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS6R-405MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,405.0,381.3,1.89,,,54.0,13.49,37.8,12.84,31.6,0.009119239999999999,-0.09707039999999999,44.4,1.3854416519227006,13.493376073672197,1.9005243140793434e-11,0.14681791055328505,586.650008603087,8.399224481475507,-0.3205,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS6R-405MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,405.0,381.5,1.95,,,54.0,13.93,37.0,13.07,31.0,0.00830228,-0.09668099999999999,43.6,1.3692752286726386,13.945470953302728,2.507748870557856e-11,0.1318010317093694,118.67325466463812,8.832801566528842,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-405MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,405.0,381.5,1.95,,,54.0,13.93,37.0,13.07,31.0,0.00830228,-0.09668099999999999,43.6,1.3692752286726386,13.945470953302728,2.507748870557856e-11,0.1318010317093694,118.67325466463812,8.832801566528842,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-410MS,CSI Solar Co Ltd,Mono-c-Si,0,410.0,385.9,1.95,,,78.0,9.98,52.7,9.37,43.8,0.0042914,-0.14366020000000002,42.9,1.9550129329623223,9.9917968566236,1.9213448337660778e-11,0.30240867909174224,255.83413715454967,5.069904294001438,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-410MS {Blk},CSI Solar Co Ltd,Mono-c-Si,0,410.0,383.5,1.97,,,66.0,11.62,44.9,10.92,37.6,0.0060888800000000005,-0.1385614,44.9,1.6898626961558834,11.63103460536074,3.294303787157417e-11,0.18781054456630086,197.77404571414615,-4.431572934650257,-0.3417,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-410MS {Wht},CSI Solar Co Ltd,Mono-c-Si,0,410.0,383.4,1.97,,,66.0,11.62,44.9,10.92,37.6,0.00555436,-0.11516850000000001,45.5,1.6219195209830002,11.62000558871629,1.1028604699669021e-11,0.20133913258955438,418624.86673581117,5.333708411389426,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3U-410MS,CSI Solar Co Ltd,Mono-c-Si,0,410.0,381.4,1.92,,,72.0,10.52,49.5,9.96,41.2,0.0039029200000000003,-0.132957,46.2,1.822444822849313,10.52634585105221,1.6656973783737828e-11,0.2651153540452962,439.5018931406029,5.0128408250029075,-0.3492,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-410P,CSI Solar Co Ltd,Multi-c-Si,0,410.0,382.2,2.14,,,72.0,11.06,47.6,10.49,39.1,0.00516502,-0.1279012,44.7,1.7613314424712059,11.064989224689873,2.0149800149999537e-11,0.294881848924571,653.6874008567694,6.0295077140538105,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-410PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,410.0,383.1,2.17,,,72.0,11.06,47.6,10.49,39.1,0.00487746,-0.12880560000000002,43.6,1.7702199442513578,11.064757370800747,2.3083943367357758e-11,0.2930333562550437,681.2479284302519,6.479827691606788,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-410MB,CSI Solar Co Ltd,Mono-c-Si,1,410.0,386.1,1.89,,,54.0,13.57,38.0,12.91,31.8,0.00917332,-0.09758399999999999,44.4,1.3937943662826082,13.573802812218458,1.949163604478032e-11,0.1437842065304647,513.0812679225618,8.572974554272795,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-410MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,410.0,386.1,1.89,,,54.0,13.57,38.0,12.91,31.8,0.00917332,-0.09758399999999999,44.4,1.3937943662826082,13.573802812218458,1.949163604478032e-11,0.1437842065304647,513.0812679225618,8.572974554272795,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-410MS-HL {Blk},CSI Solar Co Ltd,Mono-c-Si,0,410.0,386.3,1.95,,,54.0,14.01,37.2,13.15,31.2,0.00834996,-0.0972036,43.6,1.3771500003709105,14.024970680564458,2.546559331780287e-11,0.12895414257718074,120.67905249844797,8.916898757654709,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-410MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,410.0,386.3,1.95,,,54.0,14.01,37.2,13.15,31.2,0.00834996,-0.0972036,43.6,1.3771500003709105,14.024970680564458,2.546559331780287e-11,0.12895414257718074,120.67905249844797,8.916898757654709,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS1Y-415MS,CSI Solar Co Ltd,Mono-c-Si,0,415.0,390.7,1.95,,,78.0,10.02,52.8,9.44,44.0,0.004308599999999999,-0.1439328,42.9,1.9580922298947783,10.029110554471764,1.9196444523179615e-11,0.2879132855615597,316.6537394002637,5.014656229196059,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-415MS,CSI Solar Co Ltd,Mono-c-Si,0,415.0,388.2,1.97,,,66.0,11.68,45.1,10.98,37.8,0.00558304,-0.1156815,45.5,1.6536655314825366,11.691978688130378,1.638716679052919e-11,0.19328358137696577,188.46406312183242,8.814396422697676,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-415MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,415.0,384.7,2.16,,,72.0,11.22,47.7,10.46,39.7,0.0064402800000000005,-0.1481085,43.4,1.934970332270974,11.233443700785426,2.155248537883213e-10,0.20365804121773315,169.97130043493777,10.788441247916268,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-415P,CSI Solar Co Ltd,Multi-c-Si,0,415.0,386.9,2.14,,,72.0,11.14,47.8,10.56,39.3,0.00520238,-0.12843859999999999,44.7,1.7700116767314196,11.145551841046263,2.0680571091439065e-11,0.2900835885117746,582.0647982847274,6.193925898557292,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-415PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,415.0,387.1,2.17,,,72.0,11.14,47.8,10.56,39.3,0.00433346,-0.1292034,44.0,1.7744820664752499,11.145434407526038,2.2139242972093508e-11,0.2891588857164309,592.74723872134,6.248709788655757,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-415MB,CSI Solar Co Ltd,Mono-c-Si,1,415.0,391.0,1.89,,,54.0,13.65,38.2,12.98,32.0,0.0092274,-0.09809760000000001,44.4,1.4021478573372672,13.65420885991072,1.9985470771283556e-11,0.14078314486231808,456.5820664526112,8.745037540399819,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-415MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,415.0,391.0,1.89,,,54.0,13.65,38.2,12.98,32.0,0.0092274,-0.09809760000000001,44.4,1.4021478573372672,13.65420885991072,1.9985470771283556e-11,0.14078314486231808,456.5820664526112,8.745037540399819,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-415MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,415.0,391.1,1.95,,,54.0,14.09,37.4,13.23,31.4,0.00839764,-0.09772619999999999,43.6,1.3850238796459329,14.104481977469387,2.585558336366315e-11,0.12614230282743533,122.72806388711395,8.999941414343866,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-420MS,CSI Solar Co Ltd,Mono-c-Si,0,420.0,393.1,1.97,,,66.0,11.74,45.3,11.06,38.0,0.005611720000000001,-0.11619449999999999,45.5,1.6391070950526578,11.740005322251813,1.1669937187363804e-11,0.1939433414666227,427809.189970012,5.7315260794252385,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-420MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,420.0,389.4,2.16,,,72.0,11.27,47.9,10.53,39.9,0.00646898,-0.1487295,43.4,1.9416787560563884,11.281878670382882,2.13203710885604e-10,0.20028771905491716,190.02486053076356,10.643654030156945,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-420P,CSI Solar Co Ltd,Multi-c-Si,0,420.0,391.7,2.14,,,72.0,11.26,48.0,10.64,39.5,0.00525842,-0.12897599999999998,44.7,1.7809052796442626,11.268568308727724,2.1954775872830823e-11,0.2842387350741687,373.5309148989511,6.631140100518639,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-420PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,420.0,392.7,2.17,,,72.0,11.26,48.0,10.64,39.5,0.00496566,-0.129888,43.6,1.7899144076973277,11.268315536805966,2.515077231050111e-11,0.28238753567105945,382.37856231549097,7.082911370965368,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-420MB,CSI Solar Co Ltd,Mono-c-Si,1,420.0,395.8,1.89,,,54.0,13.73,38.4,13.05,32.2,0.00928148,-0.0986112,44.4,1.4105021097961903,13.734594595713723,2.0486765578605128e-11,0.137814200122207,411.82926861561225,8.915437853130078,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-420MB-HL,CSI Solar Co Ltd,Mono-c-Si,1,420.0,395.8,1.89,,,54.0,13.73,38.4,13.05,32.2,0.00928148,-0.0986112,44.4,1.4105021097961903,13.734594595713723,2.0486765578605128e-11,0.137814200122207,411.82926861561225,8.915437853130078,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6R-420MS-HL {Wht},CSI Solar Co Ltd,Mono-c-Si,0,420.0,396.0,1.95,,,54.0,14.17,37.6,13.31,31.6,0.00844532,-0.0982488,43.6,1.392896877954198,14.184004614008416,2.6247434908800338e-11,0.1233648689829429,124.82173386259544,9.081948357284176,-0.328,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-425MS,CSI Solar Co Ltd,Mono-c-Si,0,425.0,397.9,1.97,,,66.0,11.8,45.5,11.13,38.2,0.0056404,-0.1167075,45.5,1.6670564674686679,11.809460609621404,1.627487168108838e-11,0.1867052039284423,232.8730921780696,8.649030599213123,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-425MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,425.0,394.2,2.16,,,72.0,11.32,48.1,10.6,40.1,0.0064976800000000005,-0.14935050000000002,43.4,1.9484037024772838,11.33036319532581,2.1096706080070453e-10,0.19695707923562364,215.14158171926925,10.501783379335043,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-425P,CSI Solar Co Ltd,Multi-c-Si,0,425.0,396.5,2.14,,,72.0,11.29,48.2,10.71,39.7,0.00527243,-0.1295134,44.7,1.7858309360265134,11.294934096983045,2.1295150206380566e-11,0.28099651891957683,642.9648174152977,6.3285505982012875,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-425PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,425.0,392.8,2.16,,,72.0,11.29,48.2,10.71,39.7,0.00657078,-0.155927,43.1,1.9821571217976977,11.290578723786842,3.101765972018011e-10,0.241689152720649,4714.986515319778,9.33100106473282,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3N-430MS,CSI Solar Co Ltd,Mono-c-Si,0,430.0,402.7,1.97,,,66.0,11.86,45.7,11.2,38.4,0.00566908,-0.1172205,45.5,1.6562925165188616,11.860005086957305,1.2334985163534132e-11,0.18673288370472976,435361.83757322805,6.122078548034962,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-430MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,430.0,399.0,2.16,,,72.0,11.37,48.3,10.68,40.3,0.00652638,-0.1499715,43.4,1.9301000739041354,11.370005828862263,1.5406580112349203e-10,0.19833626402317608,386904.86522626,7.634061060143644,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-430MS,CSI Solar Co Ltd,Mono-c-Si,0,430.0,400.0,2.14,,,72.0,11.37,48.3,10.68,40.3,0.00570774,-0.1436925,43.3,1.8907906110529997,11.370006049145559,9.157141775073434e-11,0.206304801471642,387785.68749345787,7.843511802179497,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-430P,CSI Solar Co Ltd,Multi-c-Si,0,430.0,401.3,2.14,,,72.0,11.32,48.4,10.78,39.9,0.00528644,-0.1300508,44.7,1.7907832979149392,11.321401346591905,2.0666827820275753e-11,0.27778701422781876,2243.94824329237,6.031596815323552,-0.3516,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-430PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,430.0,401.5,2.17,,,72.0,11.32,48.4,10.78,39.9,0.00440348,-0.1308252,44.0,1.7952949908222575,11.321299626621173,2.2122051045292105e-11,0.2768719006949658,2411.608159864329,6.085210932667334,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-430H,CSI Solar Co Ltd,Mono-c-Si,0,430.0,407.0,1.98,,,54.0,14.25,38.1,13.38,32.2,0.00513,-0.094107,43.6,1.3442059574275158,14.265801982387178,6.82252103154813e-12,0.12097129018798027,109.090166339923,3.718892502851106,-0.308,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-48TM-430H,CSI Solar Co Ltd,Mono-c-Si,0,430.0,408.0,1.93,,,48.0,15.54,35.0,14.44,29.8,0.006884219999999999,-0.051065000000000006,43.7,1.1951964151126908,15.564738816455451,2.8645145900279004e-12,0.09188010829762645,57.715650459548925,62.93580121460922,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-435MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,435.0,403.8,2.16,,,72.0,11.42,48.5,10.75,40.5,0.00655508,-0.1505925,43.4,1.9406099554412728,11.420005708169398,1.5984980862672382e-10,0.19435386850079697,388855.68126823194,7.916331574336319,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-435MS,CSI Solar Co Ltd,Mono-c-Si,0,435.0,404.8,2.14,,,72.0,11.42,48.5,10.75,40.5,0.00573284,-0.14428749999999999,43.3,1.9010778871785436,11.420005928376629,9.506246973053609e-11,0.2023089463325132,389728.1194311024,8.13100398685447,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-435P,CSI Solar Co Ltd,Multi-c-Si,0,435.0,402.1,2.14,,,72.0,11.35,48.6,10.85,40.1,0.00620845,-0.1590192,42.9,2.021297005609189,11.350004313719818,4.1004398611236166e-10,0.23042945702295714,606444.7106610888,10.539772769078906,-0.4406,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-435PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,435.0,406.3,2.17,,,72.0,11.35,48.6,10.85,40.1,0.00441515,-0.1313658,44.0,1.8040362431346755,11.35000512453088,2.2660887493790514e-11,0.2730158786416499,604697.8619486325,6.26296538867819,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-435PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,435.0,407.3,2.3,,,78.0,11.35,48.6,10.85,40.1,0.0073094,-0.1301022,44.3,1.7981238717479682,11.350005149238184,2.0739932381287925e-11,0.2742020092862814,604409.9967886668,6.1970938786386105,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-435H,CSI Solar Co Ltd,Mono-c-Si,0,435.0,411.8,1.98,,,54.0,14.33,38.3,13.45,32.5,0.0051588,-0.094601,43.6,1.354152420695835,14.344844516423505,7.28288500457995e-12,0.10980873783086118,106.00272628066702,4.230280856381879,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-48TM-435H,CSI Solar Co Ltd,Mono-c-Si,0,435.0,412.8,1.93,,,48.0,15.61,35.2,14.51,30.0,0.00691523,-0.05135680000000001,43.7,1.202333495237882,15.634011189342012,2.8999566812151425e-12,0.08970737064054292,58.31997891250559,63.03952342541653,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-440MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,440.0,408.5,2.16,,,72.0,11.48,48.7,10.82,40.7,0.006589520000000001,-0.1512135,43.4,1.9685825836299076,11.486077549415496,2.0468505222653805e-10,0.18705068950218348,353.32366907015756,10.083086159653924,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-440MS,CSI Solar Co Ltd,Mono-c-Si,0,440.0,409.6,2.14,,,72.0,11.48,48.7,10.82,40.7,0.005762960000000001,-0.1448825,43.3,1.9106469312075207,11.480005702760417,9.779450696529148e-11,0.19834697226053324,399300.0946544205,8.33247536016063,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-440P,CSI Solar Co Ltd,Multi-c-Si,0,440.0,406.9,2.14,,,72.0,11.4,48.7,10.92,40.3,0.0062358,-0.1593464,42.9,2.0303822424165743,11.400002055726835,4.3659195309400455e-10,0.18025960469482244,999998.7040152284,11.061634964769727,-0.4406,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-440PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,440.0,407.1,2.16,,,72.0,11.4,48.7,10.92,40.3,0.006634800000000001,-0.15754450000000003,43.1,2.014873805372374,11.400002106916594,3.629924982684442e-10,0.18475827588787747,999998.7135372348,10.638388219775678,-0.4309,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3Y-440P,CSI Solar Co Ltd,Multi-c-Si,0,440.0,409.1,2.29,,,78.0,11.18,51.2,10.48,42.0,0.00763594,-0.1404928,46.1,1.9217334569119322,11.19590288368618,2.946351363321368e-11,0.31594619029717524,222.11559311391667,6.7239448523997005,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-440PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,440.0,412.1,2.3,,,78.0,11.18,51.2,10.48,42.0,0.007199919999999999,-0.1370624,44.3,1.9027737960184876,11.196506306588068,2.2583204530250457e-11,0.31989639245269275,216.67122658237471,7.134830502776187,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-440H,CSI Solar Co Ltd,Mono-c-Si,0,440.0,416.7,1.98,,,54.0,14.41,38.5,13.52,32.6,0.0051876,-0.095095,43.6,1.3600589230268212,14.425918952067837,7.146455543955741e-12,0.11560404984631562,104.6459812721977,4.022607569483277,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-48TM-440H,CSI Solar Co Ltd,Mono-c-Si,0,440.0,417.7,1.93,,,48.0,15.68,35.4,14.58,30.2,0.006946239999999999,-0.051648599999999996,43.7,1.2094694964007595,15.703297012640652,2.935435235304914e-12,0.08755608936518769,58.92942168382239,63.141764135711234,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-445MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,445.0,413.3,2.16,,,72.0,11.54,48.9,10.89,40.9,0.006623959999999999,-0.15183449999999998,43.4,1.9601675594335692,11.540005295236933,1.6901433144776028e-10,0.18650282511150298,406474.7022674582,8.31137210234132,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-445MS,CSI Solar Co Ltd,Mono-c-Si,0,445.0,414.4,2.14,,,72.0,11.54,48.9,10.89,40.9,0.00579308,-0.14547749999999998,43.3,1.9314795342163908,11.54617193680843,1.153713262590056e-10,0.1924450936509698,359.82488791309896,9.779397678694895,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-445P,CSI Solar Co Ltd,Multi-c-Si,0,445.0,411.6,2.14,,,72.0,11.45,48.8,10.99,40.5,0.0062631499999999994,-0.1596736,42.9,2.039288316438471,11.450001818196254,4.636313893306552e-10,0.15873513053411478,999993.278989401,11.562420331690332,-0.4406,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-445PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,445.0,411.9,2.16,,,72.0,11.45,48.8,10.99,40.5,0.0066638999999999995,-0.157868,43.1,2.023690971403172,11.450001870353333,3.8554309629874504e-10,0.16329739265012846,999993.3305133283,11.138939856782288,-0.4309,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3Y-445P,CSI Solar Co Ltd,Multi-c-Si,0,445.0,413.9,2.29,,,78.0,11.23,51.4,10.55,42.2,0.007670090000000001,-0.1410416,46.1,1.9280402438653177,11.243747803538515,2.918148084417436e-11,0.3119212459210139,254.7952929462231,6.593786437121421,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-445PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,445.0,416.9,2.3,,,78.0,11.23,51.4,10.55,42.2,0.007232120000000001,-0.1375978,44.3,1.9090309279921356,11.244322818754247,2.2367261345903824e-11,0.3158560993399152,247.65125401653435,7.003927637055944,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-445H,CSI Solar Co Ltd,Mono-c-Si,0,445.0,421.5,1.98,,,54.0,14.48,38.7,13.59,32.8,0.0052128,-0.09558900000000001,43.6,1.3675365211063142,14.495447647703696,7.244839261219236e-12,0.11310326205813527,106.01842222962273,4.096677821307693,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-48TM-445H,CSI Solar Co Ltd,Mono-c-Si,0,445.0,422.5,1.93,,,48.0,15.75,35.6,14.64,30.4,0.00697725,-0.051940400000000005,43.7,1.2169390982824697,15.773058883597301,2.9925554878153337e-12,0.08537543973514469,58.31432256929829,63.3464245710296,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-450MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,450.0,418.1,2.16,,,72.0,11.6,49.1,10.96,41.1,0.006658399999999999,-0.15245550000000002,43.4,1.9839310674227635,11.604513787573483,2.0528274550038706e-10,0.18010868904997435,462.8620501779501,10.007426591922544,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-450MS,CSI Solar Co Ltd,Mono-c-Si,0,450.0,419.2,2.14,,,72.0,11.6,49.1,10.96,41.1,0.0058232,-0.1460725,43.3,1.9297808402599783,11.600005342658678,1.0341114503491499e-10,0.19057500731270144,413794.32401400385,8.730017883339872,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-450P,CSI Solar Co Ltd,Multi-c-Si,0,450.0,416.4,2.14,,,72.0,11.53,49.0,11.06,40.7,0.00630691,-0.160328,42.9,2.0478575459053037,11.530001821643495,4.680259631743721e-10,0.15793296400584825,999996.9078224403,11.584688254861184,-0.4406,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3Y-450P,CSI Solar Co Ltd,Multi-c-Si,0,450.0,418.6,2.29,,,78.0,11.28,51.6,10.62,42.4,0.007704239999999999,-0.1415904,46.1,1.9343587694763802,11.291647434230661,2.8908521249870215e-11,0.3079455286365693,298.2309698036411,6.465891467458962,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-450PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,450.0,421.6,2.3,,,78.0,11.28,51.6,10.62,42.4,0.0072643199999999995,-0.1381332,44.3,1.9152995934044033,11.292194292203074,2.2158280082728617e-11,0.31186528224307736,288.48254239298643,6.875307083649396,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-450H,CSI Solar Co Ltd,Mono-c-Si,0,450.0,426.4,1.98,,,54.0,14.55,38.9,13.66,33.0,0.0052380000000000005,-0.096083,43.6,1.3750132498616128,14.564985842326294,7.343573721128956e-12,0.11062864571557467,107.41116594377353,4.169835681183197,-0.308,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-48TM-450H,CSI Solar Co Ltd,Mono-c-Si,0,450.0,427.4,1.93,,,48.0,15.82,35.8,14.71,30.6,0.0070082600000000005,-0.0522322,43.7,1.2240735353450818,15.84235767275865,3.0282636582705245e-12,0.08326474146842351,58.91705387203919,63.4452715648868,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-455MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,455.0,422.9,2.16,,,72.0,11.66,49.3,11.02,41.3,0.00669284,-0.1530765,43.4,1.9925603699405714,11.66430879173629,2.0781159803901559e-10,0.17652823482373176,477.70228720287434,10.069406762425793,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-455MS,CSI Solar Co Ltd,Mono-c-Si,0,455.0,429.3,2.17,,,72.0,11.66,49.3,11.02,41.3,0.006109840000000001,-0.1283772,43.4,1.7793068094482791,11.660006152679001,1.080226931992312e-11,0.21881314806218483,414677.186624504,3.4783549098973743,-0.3242,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-455P,CSI Solar Co Ltd,Multi-c-Si,0,455.0,423.4,2.29,,,78.0,11.33,51.8,10.69,42.6,0.0077383899999999995,-0.1421392,46.1,1.9406887288662988,11.339600664692549,2.864426388496572e-11,0.3040181749347497,358.7799472923957,6.340203485371426,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-455PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,455.0,426.4,2.3,,,78.0,11.33,51.8,10.69,42.6,0.00729652,-0.1386686,44.3,1.921579497912766,11.34011960919885,2.1955977077024307e-11,0.3079230731018099,344.7532793828133,6.748908485570513,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-455H,CSI Solar Co Ltd,Mono-c-Si,0,455.0,431.2,1.98,,,54.0,14.61,39.1,13.72,33.2,0.0052596,-0.096577,43.6,1.3825184152845444,14.624554058182582,7.44163486881246e-12,0.10824952031142057,108.66560198326223,4.246970930100007,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-48TM-455H,CSI Solar Co Ltd,Mono-c-Si,0,455.0,432.3,1.93,,,48.0,15.89,36.0,14.78,30.8,0.00703927,-0.052524,43.7,1.2312069414872846,15.911669344215081,3.0640030440553833e-12,0.08117459161838808,59.52484063895628,63.54272896557097,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-460MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,460.0,427.7,2.16,,,72.0,11.72,49.5,11.09,41.5,0.00672728,-0.1536975,43.4,1.9928946894495976,11.723707233081159,1.8994098724394327e-10,0.17459136058923294,551.9509804695713,9.224790110847163,-0.4057,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-460MS,CSI Solar Co Ltd,Mono-c-Si,0,460.0,428.8,2.14,,,72.0,11.72,49.5,11.09,41.5,0.005883440000000001,-0.1472625,43.3,1.9609280906973812,11.724266879288884,1.2659541334813754e-10,0.1808294925510241,496.69128923685923,10.454780115918824,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-460P,CSI Solar Co Ltd,Multi-c-Si,0,460.0,428.2,2.29,,,78.0,11.38,52.0,10.75,42.8,0.0077725400000000005,-0.14268799999999998,46.1,1.9478998231043352,11.388471199719817,2.869760799815686e-11,0.30009183213240836,403.1359222209172,6.313883802456647,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-460PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,460.0,431.2,2.3,,,78.0,11.38,52.0,10.75,42.8,0.00732872,-0.139204,44.3,1.928721913934808,11.388973507556262,2.19967206442879e-11,0.3039902787198082,385.51362359003014,6.722294676061688,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-460H,CSI Solar Co Ltd,Mono-c-Si,0,460.0,436.1,1.98,,,54.0,14.69,39.3,13.78,33.4,0.0052883999999999995,-0.09707099999999999,43.6,1.390928301838562,14.705070110397196,7.67830153189704e-12,0.10561068248758174,102.94688535807607,4.473079682161839,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-48TM-460H,CSI Solar Co Ltd,Mono-c-Si,0,460.0,437.1,1.93,,,48.0,15.96,36.2,14.84,31.0,0.007070280000000001,-0.05281580000000001,43.7,1.2386761640394444,15.981416948705151,3.1220443591903336e-12,0.07904976048055454,58.90821306867303,63.74166509064055,-0.2964,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS3W-465MS,CSI Solar Co Ltd,Mono-c-Si,0,465.0,433.6,2.14,,,72.0,11.78,49.7,11.16,41.7,0.00591356,-0.1478575,43.3,1.951699546428927,11.78382079795159,1.0201976278554248e-10,0.1807559973500809,557.2934732950137,8.502526066119373,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-465MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,465.0,434.2,2.3,,,78.0,11.42,52.3,10.67,43.6,0.006852,-0.13284200000000002,46.3,1.920842134175884,11.437339657686358,1.665066056789874e-11,0.2531154030102241,166.70327711545974,10.095850953791144,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-465P,CSI Solar Co Ltd,Multi-c-Si,0,465.0,433.0,2.29,,,78.0,11.43,52.2,10.82,43.0,0.00780669,-0.1432368,46.1,1.942676344732866,11.430011279327458,2.4461511881177772e-11,0.2983684645237805,300712.45518711925,4.8694322980816285,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-465PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,465.0,436.0,2.3,,,78.0,11.43,52.2,10.82,43.0,0.00736092,-0.1397394,44.3,1.922955634560407,11.430011871994463,1.8569786211638085e-11,0.30235037052628877,291096.154896403,5.185628594335911,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-54TM-465H,CSI Solar Co Ltd,Mono-c-Si,0,465.0,440.9,1.98,,,54.0,14.77,39.5,13.85,33.6,0.005317199999999999,-0.097565,43.6,1.3988576785374798,14.785068692385861,7.849990263281527e-12,0.10306879904602864,101.02576400726626,4.617770184452125,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3W-470MS,CSI Solar Co Ltd,Mono-c-Si,0,470.0,443.8,2.174,,,72.0,11.84,49.9,11.22,41.9,0.00620416,-0.12993960000000002,43.4,1.804546271496197,11.84000569650985,1.158967989516214e-11,0.2077520725623731,431808.0997544816,3.9441232852634136,-0.3242,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-470MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,470.0,439.0,2.3,,,78.0,11.47,52.5,10.74,43.8,0.006882,-0.13335,46.3,1.926905716226168,11.48557080507441,1.6464204455224294e-11,0.24965030716364403,183.901154747553,9.946801079389125,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-470MS,CSI Solar Co Ltd,Mono-c-Si,0,470.0,439.4,2.29,,,78.0,11.47,52.5,10.74,43.8,0.005482660000000001,-0.13466250000000002,45.5,1.8908280260983361,11.47000689961315,1.002550663721563e-11,0.25664915437817654,426658.86578391405,4.628535153620942,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-470P,CSI Solar Co Ltd,Multi-c-Si,0,470.0,437.8,2.29,,,78.0,11.48,52.4,10.88,43.2,0.007840840000000002,-0.14378559999999999,46.1,1.9614641885076312,11.485455131414335,2.850057147887353e-11,0.29241948633596915,615.3794508464906,6.166613127169064,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-470PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,470.0,440.9,2.3,,,78.0,11.48,52.4,10.88,43.2,0.00739312,-0.1402748,44.3,1.931836140201523,11.480010056448894,1.9051793472369572e-11,0.2981787223382001,340390.86830461567,5.3679096819788965,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-470H,CSI Solar Co Ltd,Mono-c-Si,0,470.0,444.7,2.19,,,60.0,14.09,42.0,13.28,35.4,0.0050723999999999995,-0.10374,43.6,1.4772275490406865,14.103410493709461,6.2080165310913185e-12,0.1434423786153181,150.71056764556,2.996893220321535,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-475MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,475.0,443.8,2.3,,,78.0,11.52,52.7,10.81,44.0,0.006912,-0.133858,46.3,1.9329816368096673,11.5338483003129,1.628373954147833e-11,0.246225796110939,204.82811018072857,9.800298085595317,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-475MS,CSI Solar Co Ltd,Mono-c-Si,0,475.0,444.2,2.29,,,78.0,11.52,52.7,10.81,44.0,0.00550656,-0.1351755,45.5,1.900201846417316,11.520006796715796,1.0393700253220751e-11,0.2525409784562858,428043.23112099885,4.899583795735302,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-475P,CSI Solar Co Ltd,Multi-c-Si,0,475.0,442.5,2.29,,,78.0,11.53,52.6,10.95,43.4,0.00787499,-0.1443344,46.1,1.967825819228542,11.533589973896914,2.8257124036072692e-11,0.28867528245086943,927.1449215370982,6.047275950362952,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-475PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,475.0,445.7,2.3,,,78.0,11.53,52.6,10.95,43.4,0.00742532,-0.1408102,44.3,1.9484781847301875,11.534021095925368,2.1659494418294487e-11,0.29253889216494633,838.8193809061328,6.45406160355235,-0.3356,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-475H,CSI Solar Co Ltd,Mono-c-Si,0,475.0,449.6,2.19,,,60.0,14.16,42.2,13.35,35.6,0.0050976,-0.10423400000000001,43.6,1.4846834336179329,14.173026157398205,6.291142034054466e-12,0.14075655380016255,153.00849998568486,3.0663067293437494,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-480MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,480.0,448.6,2.3,,,78.0,11.57,52.9,10.87,44.2,0.0069767100000000005,-0.1341544,46.3,1.9124263607176333,11.57000661260472,1.1225981839725798e-11,0.2479561599416255,433848.66503392905,6.568278165850895,-0.3228,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-480MS,CSI Solar Co Ltd,Mono-c-Si,0,480.0,449.0,2.29,,,78.0,11.57,52.9,10.87,44.2,0.005530460000000001,-0.13568850000000002,45.5,1.9088978756257622,11.57000666345461,1.0666422944942576e-11,0.24868457426573584,431802.5528626423,5.084270639395768,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-480P,CSI Solar Co Ltd,Multi-c-Si,0,480.0,447.3,2.29,,,78.0,11.58,52.8,11.01,43.6,0.00790914,-0.1448832,46.1,1.9750507776699802,11.582593193986252,2.8316518408824536e-11,0.2849223839783278,1272.3310325403481,6.023857986514925,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-480PB-AG,CSI Solar Co Ltd,Multi-c-Si,1,480.0,450.5,2.3,,,78.0,11.58,52.8,11.01,43.6,0.00745752,-0.14134560000000002,44.3,1.9556342432742095,11.583008069165713,2.170489663246858e-11,0.28877995640984144,1111.700507848045,6.4303769612828185,-0.3356,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-60TM-480H,CSI Solar Co Ltd,Mono-c-Si,0,480.0,454.4,2.19,,,60.0,14.23,42.4,13.42,35.8,0.0051228,-0.104728,43.6,1.4921387182421904,14.242649673437414,6.374621322150392e-12,0.1380992122201991,155.35197837626492,3.1349686628190967,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-485MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,485.0,453.4,2.3,,,78.0,11.62,53.1,10.94,44.4,0.006972,-0.13487400000000002,46.3,1.9217809656964808,11.620006520557716,1.1624543734256225e-11,0.24395644144248743,434746.6895142636,6.669241695507784,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-485MS,CSI Solar Co Ltd,Mono-c-Si,0,485.0,453.8,2.29,,,78.0,11.62,53.1,10.94,44.4,0.00555436,-0.1362015,45.5,1.9182704983564665,11.62000656673565,1.1051367346280645e-11,0.2446759570196845,432962.5937103236,5.351419570275267,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-485P,CSI Solar Co Ltd,Multi-c-Si,0,485.0,452.1,2.29,,,78.0,11.63,53.0,11.08,43.8,0.00794329,-0.145432,46.1,1.981427293543283,11.630813912815727,2.8082582546209624e-11,0.2812651464297602,4018.998183943582,5.907503040707424,-0.3398,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-485H,CSI Solar Co Ltd,Mono-c-Si,0,485.0,459.2,2.19,,,60.0,14.3,42.6,13.49,36.0,0.005148,-0.10522200000000001,43.6,1.49959340440406,14.312280903548933,6.458450012586359e-12,0.1354699037130104,157.74243480406957,3.202889869839124,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-490MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,490.0,458.2,2.3,,,78.0,11.67,53.3,11.0,44.6,0.0070019999999999995,-0.135382,46.3,1.9298054874035235,11.68083743294871,1.1609748305534064e-11,0.24069858888149648,259.18984278210377,6.682788493642423,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-490MS,CSI Solar Co Ltd,Mono-c-Si,0,490.0,458.6,2.29,,,78.0,11.67,53.3,11.0,44.6,0.00557826,-0.13671450000000002,45.5,1.9502280083631531,11.680342439601477,1.5510943167223755e-11,0.2365385406177739,266.9007399186407,8.324421455876982,-0.332,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-60TM-490H,CSI Solar Co Ltd,Mono-c-Si,0,490.0,464.1,2.19,,,60.0,14.37,42.8,13.55,36.2,0.005173199999999999,-0.10571599999999999,43.6,1.5075691662723147,14.382481171522873,6.601543554448536e-12,0.1328020122384301,152.89950219297458,3.349364234376437,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-495MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,495.0,463.0,2.3,,,78.0,11.72,53.5,11.06,44.8,0.00706716,-0.135676,46.3,1.9390442940647226,11.720006281478074,1.2199516737448868e-11,0.23649527509932863,441256.2864877308,7.182013948528355,-0.3228,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-495H,CSI Solar Co Ltd,Mono-c-Si,0,495.0,468.9,2.19,,,60.0,14.44,43.0,13.61,36.4,0.0051984,-0.10621,43.6,1.515546213632614,14.45266518945625,6.74659664716022e-12,0.13015739636360624,148.39673609514836,3.494675672452426,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-500MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,500.0,467.8,2.3,,,78.0,11.77,53.7,11.12,45.0,0.00709731,-0.1361832,46.3,1.9477033148100067,11.770006170803523,1.2498780173035966e-11,0.23281954936492083,444075.5891266647,7.3570382922840425,-0.3228,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-500MS,CSI Solar Co Ltd,Mono-c-Si,0,500.0,468.2,2.29,,,78.0,11.77,53.7,11.12,45.0,0.0056260600000000004,-0.13774050000000002,45.5,1.9443546124300768,11.770006213509607,1.1919151074241347e-11,0.23349446514906225,442301.7411423907,5.891710122055905,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-500H,CSI Solar Co Ltd,Mono-c-Si,0,500.0,473.8,2.19,,,60.0,14.51,43.2,13.67,36.6,0.0052236,-0.10670400000000001,43.6,1.5235245316464119,14.522833217832664,6.893615980296228e-12,0.1275357510900163,144.19951193347688,3.6388380326723544,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS3Y-505MS,CSI Solar Co Ltd,Mono-c-Si,0,505.0,473.0,2.29,,,78.0,11.82,53.9,11.18,45.2,0.00564996,-0.1382535,45.5,1.9530485420530317,11.820006105242904,1.2218168159558444e-11,0.22984745409645788,444996.7619296687,6.069042924706808,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-505H,CSI Solar Co Ltd,Mono-c-Si,0,505.0,478.6,2.19,,,60.0,14.58,43.4,13.73,36.8,0.0052488,-0.107198,43.6,1.5315040886490912,14.592985502245746,7.042605973897927e-12,0.12493677942279195,140.2778430618108,3.781862318548963,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-510H,CSI Solar Co Ltd,Mono-c-Si,0,510.0,483.5,2.19,,,60.0,14.65,43.6,13.79,37.0,0.005274,-0.107692,43.6,1.5394848878683305,14.663122301940602,7.193575126728858e-12,0.12236018411061447,136.60535380904415,3.9237648137855494,-0.308,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS6W-510MB,CSI Solar Co Ltd,Mono-c-Si,1,510.0,479.5,2.53,,,72.0,13.6,48.0,12.72,40.1,0.0091936,-0.12326399999999998,44.4,1.7317621738990407,13.620279160183502,1.2152922925420259e-11,0.19317767127531402,129.55252146411217,4.513815461767461,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS61-60TM-515H,CSI Solar Co Ltd,Mono-c-Si,0,515.0,488.4,2.19,,,60.0,14.72,43.8,13.85,37.2,0.0052992,-0.108186,43.6,1.5474669228451645,14.73324386454508,7.346530638299548e-12,0.11980567478031562,133.15898307768256,4.064559518956127,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-515MB,CSI Solar Co Ltd,Mono-c-Si,1,515.0,484.3,2.53,,,72.0,13.65,48.2,12.78,40.3,0.0092274,-0.1237776,44.4,1.7806655323215461,13.667621187956518,2.339064940959221e-11,0.18306188117158975,141.8062558742499,10.214102487934195,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-520MB,CSI Solar Co Ltd,Mono-c-Si,1,520.0,489.1,2.53,,,72.0,13.7,48.4,12.84,40.5,0.009261199999999997,-0.12429119999999998,44.4,1.787894532736582,13.716581478594803,2.344621375588599e-11,0.18031758289913496,148.98254607512249,10.19861644533027,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-520MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,520.0,488.7,2.5,,,72.0,13.7,48.4,12.84,40.5,0.006411599999999999,-0.12453319999999998,44.5,1.7582807748502522,13.717633619050991,1.485038246699486e-11,0.1854851009234148,144.10801802989567,6.249634854382599,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-525MB,CSI Solar Co Ltd,Mono-c-Si,1,525.0,493.9,2.53,,,72.0,13.75,48.6,12.9,40.7,0.009295,-0.1248048,44.4,1.795123030087595,13.765569923901593,2.350165085938462e-11,0.177599342899404,156.84026398235164,10.183171524962098,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-525MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,525.0,493.6,2.5,,,72.0,13.75,48.6,12.9,40.7,0.006435000000000001,-0.1250478,44.5,1.7653868640589203,13.766592809679377,1.4884253681307383e-11,0.18276586608917667,151.45299162326683,6.233706197857914,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-530MB,CSI Solar Co Ltd,Mono-c-Si,1,530.0,498.7,2.53,,,72.0,13.8,48.8,12.96,40.9,0.0093288,-0.1253184,44.4,1.8023510500966766,13.814586024151328,2.3556969632415876e-11,0.174906788639057,165.48126292260514,10.167769202147518,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-530MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,530.0,498.4,2.5,,,72.0,13.8,48.8,12.96,40.9,0.0064584,-0.1255624,44.5,1.7724925365021658,13.81557976876678,1.49180646076816e-11,0.18007230997006027,159.50158985912915,6.217834512040582,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-530MS,CSI Solar Co Ltd,Mono-c-Si,0,530.0,497.4,2.49,,,72.0,13.8,48.8,12.96,40.9,0.0073416,-0.1255624,45.4,1.7762681145457653,13.81545212606452,1.5818620789684042e-11,0.17941736293741675,160.2342360933438,6.637208548467088,-0.3201,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-535MB,CSI Solar Co Ltd,Mono-c-Si,1,535.0,503.6,2.53,,,72.0,13.85,49.0,13.02,41.1,0.0093626,-0.12583199999999997,44.4,1.8095785818894647,13.863629273785072,2.3612166835725e-11,0.17223955896958812,175.02898098779863,10.152409144244999,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-535MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,535.0,503.2,2.5,,,72.0,13.85,49.0,13.02,41.1,0.006481800000000001,-0.126077,44.5,1.7795977916868262,13.86459399402006,1.4951815251890234e-11,0.1774040705793716,168.36010657157664,6.202019346907257,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-535MS,CSI Solar Co Ltd,Mono-c-Si,0,535.0,502.2,2.49,,,72.0,13.85,49.0,13.02,41.1,0.0073682,-0.126077,45.4,1.78338975142616,13.864469996324948,1.5854798927452706e-11,0.17674909247983492,169.17591985186795,6.621629728406795,-0.3201,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-540MB,CSI Solar Co Ltd,Mono-c-Si,1,540.0,508.4,2.53,,,72.0,13.9,49.2,13.08,41.3,0.0093964,-0.1263456,44.4,1.8168056506729557,13.912699197817718,2.3667251244461023e-11,0.1695972944046176,185.63396191463016,10.137094520396145,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-540MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,540.0,508.0,2.5,,,72.0,13.9,49.2,13.08,41.3,0.006505200000000001,-0.1265916,44.5,1.7867026377622146,13.913635000157779,1.4985507524955043e-11,0.17476079115412074,178.15731091109686,6.186261784533009,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-540MS,CSI Solar Co Ltd,Mono-c-Si,0,540.0,507.0,2.49,,,72.0,13.9,49.2,13.08,41.3,0.0073948,-0.1265916,45.4,1.790510959164063,13.913514636149552,1.5890909350756857e-11,0.17410578678545136,179.0703366100576,6.606102657760214,-0.3201,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-545MB,CSI Solar Co Ltd,Mono-c-Si,1,545.0,513.2,2.53,,,72.0,13.95,49.4,13.14,41.5,0.009430199999999998,-0.12685919999999998,44.4,1.8240322518896495,13.961795315858046,2.37222215796117e-11,0.1669796473583671,197.4822987385416,10.12182351124492,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-545MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,545.0,512.8,2.5,,,72.0,13.95,49.4,13.14,41.5,0.0065286,-0.12710619999999997,44.5,1.7938070854104367,13.962702313748242,1.5019143831957193e-11,0.1721421219798043,189.05080264971127,6.17056158687019,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-545MS,CSI Solar Co Ltd,Mono-c-Si,0,545.0,511.8,2.49,,,72.0,13.95,49.4,13.14,41.5,0.007421399999999999,-0.12710619999999997,45.4,1.797631746278505,13.962585571962613,1.5926954186588982e-11,0.1714870956207675,190.07836937646056,6.590628525187509,-0.3201,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-550MB,CSI Solar Co Ltd,Mono-c-Si,1,550.0,518.0,2.53,,,72.0,14.0,49.6,13.2,41.7,0.009464,-0.1273728,44.4,1.831258397211402,14.010917168337851,2.3777082061781848e-11,0.16438627348004206,210.8062979440419,10.10659786658755,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-550MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,550.0,517.7,2.5,,,72.0,14.0,49.6,13.2,41.7,0.0065520000000000005,-0.1276208,44.5,1.8009111413246999,14.01179547168194,1.5052725758442587e-11,0.16954771929382362,201.2355374136264,6.154920435617126,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-550MS,CSI Solar Co Ltd,Mono-c-Si,0,550.0,516.6,2.49,,,72.0,14.0,49.6,13.2,41.7,0.007448000000000001,-0.1276208,45.4,1.8047521191675482,14.011682337866752,1.5962934936591133e-11,0.16889267728176155,202.3993414622693,6.5752050438658936,-0.3201,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS6W-555MB,CSI Solar Co Ltd,Mono-c-Si,1,555.0,522.9,2.53,,,72.0,14.05,49.8,13.25,41.9,0.0094978,-0.12788639999999998,44.4,1.8391509912821637,14.060644611826104,2.4045757605602004e-11,0.1617299787341366,213.47008756808586,10.174832142167924,-0.3205,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-555MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,555.0,522.5,2.5,,,72.0,14.05,49.8,13.26,41.9,0.006575400000000001,-0.12813539999999998,44.5,1.8080148092459978,14.060914019080993,1.5086254187552996e-11,0.16697724694750293,214.9556745264655,6.139337967025191,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-555MS,CSI Solar Co Ltd,Mono-c-Si,0,555.0,521.4,2.49,,,72.0,14.05,49.8,13.25,41.9,0.0074746000000000005,-0.12813539999999998,45.4,1.8125275520065007,14.061400766200778,1.6144381074160304e-11,0.16624144899524532,204.87152576269068,6.641783155100352,-0.3201,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-560MS,CSI Solar Co Ltd,Mono-c-Si,0,560.0,526.3,2.49,,,72.0,14.1,50.0,13.31,42.1,0.007501199999999999,-0.12865,45.4,1.819645975913115,14.110538023970365,1.617974063206332e-11,0.16369334372572739,219.0236202740894,6.626010486479392,-0.3201,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-565TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,565.0,536.1,2.51,,,72.0,13.75,51.6,13.3,42.5,0.0062562500000000005,-0.09546,44.1,1.6209103265651665,13.750007568883678,2.055820748307836e-13,0.293810098317689,533749.7894269044,3.3850836557964383,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-570TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,570.0,541.0,2.51,,,72.0,13.81,51.8,13.35,42.7,0.00628355,-0.09583,44.1,1.6261111498282772,13.810007570288876,2.0215239056255283e-13,0.29108076467539934,531000.4136675405,3.1943289515902045,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS7L-570MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,570.0,534.7,2.14,,,60.0,18.17,40.1,16.93,33.7,0.009648270000000002,-0.1172925,43.7,1.5969969884476756,18.190073221304083,2.2014488501677266e-10,0.08825385057194009,79.88615633848295,13.43269604953731,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS6W-575TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,575.0,545.8,2.51,,,72.0,13.88,52.0,13.41,42.9,0.0063154000000000005,-0.09620000000000001,44.1,1.757701399372351,13.880045681554508,1.9686245130586627e-12,0.26673132733300126,81044.353260214,25.21926412455329,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS7L-575MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,575.0,539.6,2.14,,,60.0,18.22,40.3,16.97,33.9,0.00967482,-0.11787749999999998,43.7,1.60611775911989,18.23999836754643,2.246512470149903e-10,0.08622270437176041,78.5552970427749,13.595048888959777,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-575MS-R,CSI Solar Co Ltd,Mono-c-Si,0,575.0,540.1,2.8,,,60.0,18.22,40.3,16.97,33.9,0.013009080000000001,-0.1073592,44.2,1.5239104629582114,18.24454102483822,5.789239502609743e-11,0.09692240762297366,71.95813082978111,11.642485417528054,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS6W-580TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,580.0,550.7,2.51,,,72.0,13.93,52.2,13.46,43.1,0.00633815,-0.09657,44.1,1.7650656920801893,13.930048922078218,1.995808905074564e-12,0.26383582922335935,75124.24519368724,25.325047384742906,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS7L-580MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,580.0,544.5,2.14,,,60.0,18.27,40.5,17.02,34.1,0.00970137,-0.1184625,43.7,1.6147345674874958,18.28943124355351,2.2757436191431626e-10,0.0842692215985187,79.23315371555663,13.687960359525622,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-580MS-R,CSI Solar Co Ltd,Mono-c-Si,0,580.0,544.9,2.8,,,60.0,18.27,40.5,17.02,34.1,0.01304478,-0.10789200000000002,44.2,1.5320555943033265,18.29392421012932,5.864655467335029e-11,0.09500535389706774,72.55193861251585,11.73464414755907,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-585H,CSI Solar Co Ltd,Mono-c-Si,1,585.0,557.0,2.62,,,72.0,14.36,51.2,13.48,43.4,0.009118600000000001,-0.1206784,44.1,1.7815200565990097,14.376040474977572,4.623290320776502e-12,0.15515507653655153,138.90030711565382,4.8391125353343885,-0.2714,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-585H,CSI Solar Co Ltd,Mono-c-Si,1,585.0,555.8,2.62,,,66.0,15.67,47.0,14.71,39.8,0.00930798,-0.099029,44.1,1.6343876495652034,15.687866729323769,4.958315961444518e-12,0.13363058086585586,117.20058919206525,17.305082286893796,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-585HR,CSI Solar Co Ltd,Mono-c-Si,1,585.0,553.2,2.62,,,22.0,15.1,48.3,14.07,41.6,0.012231,-0.1314726,43.7,1.836801194226903,15.109438384778455,5.560534094452691e-11,0.06277584491135221,100.43193598298805,10.43812053190381,-0.3144,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS6W-585TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,585.0,555.5,2.51,,,72.0,14.0,52.4,13.52,43.3,0.006370000000000001,-0.09694,44.1,1.7721530296229873,14.000003506124534,2.0168201265289924e-12,0.23094044136267777,922150.6008379149,25.381930806710724,-0.2908,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-585MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,585.0,549.3,2.14,,,60.0,18.32,40.7,17.06,34.3,0.009727920000000001,-0.1190475,43.7,1.6238580836345915,18.339333080837484,2.321579616889351e-10,0.08225780496367674,77.94738082782729,13.847836819782712,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-585MS-R,CSI Solar Co Ltd,Mono-c-Si,0,585.0,549.7,2.8,,,60.0,18.32,40.7,17.06,34.3,0.01308048,-0.10842480000000002,44.2,1.5406541443651554,18.343840266359067,5.982609940114486e-11,0.09304483673343428,71.50009910334752,11.892675385707902,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-590H,CSI Solar Co Ltd,Mono-c-Si,1,590.0,561.8,2.62,,,72.0,14.42,51.4,13.54,43.6,0.0091567,-0.1211498,44.1,1.7888482903940768,14.43567143922732,4.6714281997319044e-12,0.1525872877375932,140.40246456170215,4.891922365639385,-0.2714,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-590H,CSI Solar Co Ltd,Mono-c-Si,1,590.0,560.7,2.62,,,66.0,15.73,47.2,14.76,40.0,0.00934362,-0.09945040000000001,44.1,1.6422287041138859,15.747998307569326,5.0522742413941525e-12,0.13129678026945232,114.74958671221283,17.45282756009892,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-590HP,CSI Solar Co Ltd,Mono-c-Si,1,590.0,560.7,2.62,,,66.0,15.73,47.2,14.76,40.0,0.00934362,-0.09945040000000001,44.1,1.6422287041138859,15.747998307569326,5.0522742413941525e-12,0.13129678026945232,114.74958671221283,17.45282756009892,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-590HR,CSI Solar Co Ltd,Mono-c-Si,1,590.0,558.1,2.62,,,22.0,15.16,48.5,14.13,41.8,0.012279600000000002,-0.132017,43.7,1.8447620112547598,15.16905825322109,5.612550952200417e-11,0.060597004120451166,101.41586503677385,10.485268610724983,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS6W-590TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,590.0,560.4,2.51,,,72.0,14.06,52.6,13.57,43.5,0.0063973,-0.09731000000000001,44.1,1.779052108286322,14.060003515905516,2.0300179672740074e-12,0.23051736275917967,921834.4485447888,25.405426220920766,-0.2908,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-590MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,590.0,554.2,2.14,,,60.0,18.37,40.9,17.11,34.5,0.009754470000000001,-0.11963249999999999,43.7,1.6324732660608785,18.388770128782664,2.351096558911329e-10,0.08032696113050675,78.61460729539172,13.938382799136004,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-590MS-R,CSI Solar Co Ltd,Mono-c-Si,0,590.0,554.5,2.8,,,60.0,18.37,40.9,17.11,34.5,0.013116180000000002,-0.1089576,44.2,1.548797531675437,18.393228324330344,6.05874125266058e-11,0.09114998249387869,72.08549196700213,11.982446258691041,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-595H,CSI Solar Co Ltd,Mono-c-Si,1,595.0,566.7,2.62,,,72.0,14.48,51.6,13.59,43.8,0.009194800000000001,-0.1216212,44.1,1.7967893232961265,14.49583285204201,4.762120015651072e-12,0.1499569980541692,137.14378984970998,5.025184590857589,-0.2714,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-595H,CSI Solar Co Ltd,Mono-c-Si,1,595.0,565.5,2.62,,,66.0,15.79,47.4,14.81,40.2,0.009379259999999999,-0.0998718,44.1,1.6500709657307715,15.808115132268666,5.147309284159249e-12,0.1289784563168195,112.42367963142857,17.59952425237116,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-595HP,CSI Solar Co Ltd,Mono-c-Si,1,595.0,565.5,2.62,,,66.0,15.79,47.4,14.81,40.2,0.009379259999999999,-0.0998718,44.1,1.6500709657307715,15.808115132268666,5.147309284159249e-12,0.1289784563168195,112.42367963142857,17.59952425237116,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-595HR,CSI Solar Co Ltd,Mono-c-Si,1,595.0,562.9,2.62,,,22.0,15.23,48.7,14.18,42.0,0.012336300000000001,-0.13256140000000002,43.7,1.854030684225511,15.239083201168993,5.765236372191166e-11,0.05809362566332445,97.40683992635589,10.689805601660904,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS6W-595TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,595.0,565.3,2.51,,,72.0,14.12,52.8,13.62,43.7,0.006424599999999999,-0.09768,44.1,1.7859512086563059,14.12000352510431,2.0432302413754766e-12,0.23006169839581772,921527.3158433068,25.428747429559554,-0.2908,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-595MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,595.0,559.1,2.14,,,60.0,18.42,41.1,17.15,34.7,0.009781020000000001,-0.1202175,43.7,1.6415995003938122,18.438649478895393,2.397700241835979e-10,0.07833495798755528,77.37106009481168,14.09585502578703,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-595MS-R,CSI Solar Co Ltd,Mono-c-Si,0,595.0,559.3,2.8,,,60.0,18.42,41.1,17.15,34.7,0.013151880000000003,-0.10949040000000002,44.2,1.5573980711314277,18.443122731617567,6.178633462636798e-11,0.08920851936896923,71.06517353477763,12.138029265201418,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-600H,CSI Solar Co Ltd,Mono-c-Si,1,600.0,571.6,2.62,,,72.0,14.54,51.8,13.64,44.0,0.0092329,-0.1220926,44.1,1.8047315873124534,14.555980795178945,4.853937051217286e-12,0.14734568369685117,134.0613038442295,5.157583607246417,-0.2714,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-66HB-600H,CSI Solar Co Ltd,Mono-c-Si,1,600.0,573.9,2.62,,,66.0,15.2,49.8,14.14,42.4,0.0102296,-0.1084644,44.4,1.687160466357078,15.223972728910374,2.22144046165915e-12,0.13595311283084993,86.20158861423859,6.313689859207192,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-600HP,CSI Solar Co Ltd,Mono-c-Si,1,600.0,573.9,2.62,,,66.0,15.2,49.8,14.14,42.4,0.0102296,-0.1084644,44.4,1.687160466357078,15.223972728910374,2.22144046165915e-12,0.13595311283084993,86.20158861423859,6.313689859207192,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-600H,CSI Solar Co Ltd,Mono-c-Si,1,600.0,570.4,2.62,,,66.0,15.85,47.6,14.86,40.4,0.0094149,-0.10029320000000001,44.1,1.657914422506552,15.868217417639025,5.243423582252219e-12,0.1266754541569537,110.21353243009138,17.74518362598712,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-600HP,CSI Solar Co Ltd,Mono-c-Si,1,600.0,570.4,2.62,,,66.0,15.85,47.6,14.86,40.4,0.0094149,-0.10029320000000001,44.1,1.657914422506552,15.868217417639025,5.243423582252219e-12,0.1266754541569537,110.21353243009138,17.74518362598712,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-600HR,CSI Solar Co Ltd,Mono-c-Si,1,600.0,567.8,2.62,,,22.0,15.3,48.9,14.23,42.2,0.012393,-0.1331058,43.7,1.8633038910170756,15.309076153519165,5.921002009766595e-11,0.055606306435199364,93.73756072734426,10.89321819750679,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS6W-600TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,600.0,570.1,2.51,,,72.0,14.18,53.0,13.68,43.9,0.0064519,-0.09805,44.1,1.7933301536964756,14.18000348657374,2.072787006846969e-12,0.2266947068604815,921976.6314894024,25.53469172490157,-0.2908,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-600MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,600.0,564.0,2.14,,,60.0,18.47,41.3,17.2,34.9,0.00980757,-0.1208025,43.7,1.6502130768606762,18.48809088348387,2.427494660031833e-10,0.07642637336464823,78.02798259787116,14.184109849033563,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-600MS-R,CSI Solar Co Ltd,Mono-c-Si,0,600.0,564.2,2.8,,,60.0,18.47,41.3,17.2,34.9,0.01318758,-0.1100232,44.2,1.565539733945822,18.49251581568551,6.255457329792076e-11,0.08733549171535146,71.64237630191806,12.22548927607997,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-600TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,600.0,568.3,2.75,,,60.0,18.11,42.1,17.2,34.9,0.01218803,-0.10099790000000002,44.8,1.4726758851759985,18.120297928705895,6.901784373705102e-12,0.14983108468048176,263.49385697152695,4.3145198438214845,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-605H,CSI Solar Co Ltd,Mono-c-Si,1,605.0,576.4,2.62,,,72.0,14.6,52.0,13.69,44.2,0.009271,-0.122564,44.1,1.8126745838705842,14.616115204219808,4.946847642507871e-12,0.14475321533388336,131.14304456654122,5.289062781299533,-0.2714,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-66HB-605H,CSI Solar Co Ltd,Mono-c-Si,1,605.0,578.8,2.62,,,66.0,15.3,49.9,14.25,42.5,0.0102969,-0.10868219999999999,44.4,1.6899059021172056,15.323070056563374,2.214123620270915e-12,0.13428234925870147,89.05569600513127,6.220705182369394,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-605HP,CSI Solar Co Ltd,Mono-c-Si,1,605.0,578.8,2.62,,,66.0,15.3,49.9,14.25,42.5,0.0102969,-0.10868219999999999,44.4,1.6899059021172056,15.323070056563374,2.214123620270915e-12,0.13428234925870147,89.05569600513127,6.220705182369394,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-605H,CSI Solar Co Ltd,Mono-c-Si,1,605.0,575.3,2.62,,,66.0,15.91,47.8,14.91,40.6,0.00945054,-0.1007146,44.1,1.6657590626879943,15.92830537365886,5.340619561561894e-12,0.1243876210265127,108.11071594226631,17.88981678041671,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-605HP,CSI Solar Co Ltd,Mono-c-Si,1,605.0,575.3,2.62,,,66.0,15.91,47.8,14.91,40.6,0.00945054,-0.1007146,44.1,1.6657590626879943,15.92830537365886,5.340619561561894e-12,0.1243876210265127,108.11071594226631,17.88981678041671,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-605HR,CSI Solar Co Ltd,Mono-c-Si,1,605.0,572.6,2.62,,,22.0,15.36,49.1,14.29,42.4,0.012441599999999999,-0.13365020000000002,43.7,1.8712634277725908,15.368682590842472,5.974265145893563e-11,0.0534826291008767,94.61383140336967,10.937790388156852,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-605MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,605.0,568.9,2.14,,,60.0,18.52,41.5,17.25,35.1,0.00983412,-0.12138750000000001,43.7,1.6588250831371587,18.537540759153764,2.45734049531227e-10,0.07452942193169293,78.69014717049717,14.271300639076644,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-605MS-R,CSI Solar Co Ltd,Mono-c-Si,0,605.0,569.0,2.8,,,60.0,18.52,41.5,17.25,35.1,0.01322328,-0.11055600000000002,44.2,1.573679895174261,18.541917701487442,6.332407111202986e-11,0.08547387414280765,72.22363886867988,12.311880349929869,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-605TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,605.0,573.2,2.75,,,60.0,18.16,42.3,17.24,35.1,0.01222168,-0.1014777,44.8,1.4806483639753458,18.170890349454744,7.0483253803324395e-12,0.14786048029472726,246.56199897300482,4.4742354161425535,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-610H,CSI Solar Co Ltd,Mono-c-Si,1,610.0,581.3,2.62,,,72.0,14.66,52.2,13.74,44.4,0.0093091,-0.1230354,44.1,1.8206191437199841,14.676236650411205,5.040918077713191e-12,0.14217925724667516,128.37302360406068,5.419743494993331,-0.2714,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-66HB-610H,CSI Solar Co Ltd,Mono-c-Si,1,610.0,583.7,2.62,,,66.0,15.42,50.0,14.36,42.6,0.01037766,-0.1089,44.4,1.6936575698155554,15.443145678781026,2.2453511253048223e-12,0.1323234120968498,88.15585121968098,6.276545752378497,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-610HP,CSI Solar Co Ltd,Mono-c-Si,1,610.0,583.7,2.62,,,66.0,15.42,50.0,14.36,42.6,0.01037766,-0.1089,44.4,1.6936575698155554,15.443145678781026,2.2453511253048223e-12,0.1323234120968498,88.15585121968098,6.276545752378497,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-610H,CSI Solar Co Ltd,Mono-c-Si,1,610.0,580.1,2.62,,,66.0,15.97,48.0,14.96,40.8,0.00948618,-0.10113599999999999,44.1,1.6736048746753978,15.988379206174665,5.4388995819715355e-12,0.12211480621402411,106.10759996812178,18.03343465527677,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-610HP,CSI Solar Co Ltd,Mono-c-Si,1,610.0,580.1,2.62,,,66.0,15.97,48.0,14.96,40.8,0.00948618,-0.10113599999999999,44.1,1.6736048746753978,15.988379206174665,5.4388995819715355e-12,0.12211480621402411,106.10759996812178,18.03343465527677,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-610HR,CSI Solar Co Ltd,Mono-c-Si,1,610.0,577.5,2.62,,,22.0,15.43,49.3,14.34,42.6,0.0124983,-0.1341946,43.7,1.8805409207603843,15.438634192471447,6.133731126751702e-11,0.051029097067977466,91.19312238651622,11.139067789525905,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-610MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,610.0,573.7,2.14,,,60.0,18.57,41.7,17.29,35.3,0.00986067,-0.1219725,43.7,1.6679540064230491,18.587394449753056,2.5049253881861375e-10,0.07256678201706163,77.47098559095625,14.425269939957072,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-610MS-R,CSI Solar Co Ltd,Mono-c-Si,0,610.0,573.8,2.8,,,60.0,18.57,41.7,17.29,35.3,0.013258980000000002,-0.11108880000000002,44.2,1.582282235759522,18.591787562546344,6.454770570982286e-11,0.08356121274292565,71.22098789265969,12.463912227226023,-0.3309,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-610TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,610.0,578.0,2.75,,,60.0,18.21,42.5,17.29,35.3,0.01225533,-0.10195749999999999,44.8,1.488237490915408,18.220647265983786,7.148592414805159e-12,0.14590872205857672,249.54742762727278,4.572242311906346,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-615H,CSI Solar Co Ltd,Mono-c-Si,1,615.0,586.2,2.62,,,72.0,14.72,52.4,13.79,44.6,0.0093472,-0.1235068,44.1,1.8285639997707697,14.736344712325542,5.136057975649451e-12,0.13962380671180816,125.74479104779901,5.5494663737771175,-0.2714,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-66HB-615H,CSI Solar Co Ltd,Mono-c-Si,1,615.0,588.6,2.62,,,66.0,15.53,50.0,14.46,42.6,0.01045169,-0.1089,44.4,1.6937871219695215,15.553433082838978,2.2660338291550853e-12,0.1313681814311382,87.06271693334511,6.295660270482114,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-615HP,CSI Solar Co Ltd,Mono-c-Si,1,615.0,588.6,2.62,,,66.0,15.53,50.0,14.46,42.6,0.01045169,-0.1089,44.4,1.6937871219695215,15.553433082838978,2.2660338291550853e-12,0.1313681814311382,87.06271693334511,6.295660270482114,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-615H,CSI Solar Co Ltd,Mono-c-Si,1,615.0,585.0,2.62,,,66.0,16.02,48.2,15.01,41.0,0.00951588,-0.1015574,44.1,1.6809797402889681,16.03796506896943,5.494442659207015e-12,0.11999613323093669,107.00421244165149,18.10136255977025,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-615HP,CSI Solar Co Ltd,Mono-c-Si,1,615.0,585.0,2.62,,,66.0,16.02,48.2,15.01,41.0,0.00951588,-0.1015574,44.1,1.6809797402889681,16.03796506896943,5.494442659207015e-12,0.11999613323093669,107.00421244165149,18.10136255977025,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-615HR,CSI Solar Co Ltd,Mono-c-Si,1,615.0,582.3,2.62,,,22.0,15.5,49.5,14.39,42.8,0.012555,-0.134739,43.7,1.8898229911060618,15.508554697801545,6.296358882741127e-11,0.048591104703631136,88.04076350575234,11.339266731172035,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-615TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,615.0,582.9,2.75,,,60.0,18.26,42.7,17.33,35.5,0.012288980000000001,-0.10243730000000001,44.8,1.4962121482073658,18.27120587893375,7.298006815673759e-12,0.14395719073566163,234.57850353256114,4.72960172714426,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-620H,CSI Solar Co Ltd,Mono-c-Si,1,620.0,591.0,2.62,,,72.0,14.78,52.6,13.84,44.8,0.0093853,-0.1239782,44.1,1.8365102383959246,14.796440064717174,5.232353700433245e-12,0.1370864938878185,123.24394190760482,5.6783864817011365,-0.2714,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-620H,CSI Solar Co Ltd,Mono-c-Si,1,620.0,593.5,2.62,,,66.0,15.65,50.1,14.58,42.6,0.01053245,-0.1091178,44.4,1.6951825757599999,15.674313327110188,2.2075124187353884e-12,0.13729082789563277,88.37134660057256,5.990999615123769,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-620HP,CSI Solar Co Ltd,Mono-c-Si,1,620.0,593.5,2.62,,,66.0,15.65,50.1,14.58,42.6,0.01053245,-0.1091178,44.4,1.6951825757599999,15.674313327110188,2.2075124187353884e-12,0.13729082789563277,88.37134660057256,5.990999615123769,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-620H,CSI Solar Co Ltd,Mono-c-Si,1,620.0,589.9,2.62,,,66.0,16.08,48.4,15.06,41.2,0.00955152,-0.1019788,44.1,1.6888266054493928,16.09802133602274,5.594214183035677e-12,0.11775288003634458,105.06803217570273,18.243089894099054,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-620HP,CSI Solar Co Ltd,Mono-c-Si,1,620.0,589.9,2.62,,,66.0,16.08,48.4,15.06,41.2,0.00955152,-0.1019788,44.1,1.6888266054493928,16.09802133602274,5.594214183035677e-12,0.11775288003634458,105.06803217570273,18.243089894099054,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-620HR,CSI Solar Co Ltd,Mono-c-Si,1,620.0,587.2,2.62,,,22.0,15.56,49.7,14.42,43.0,0.012603600000000001,-0.13528340000000003,43.7,1.8998516164989532,15.568598109790896,6.518646228787617e-11,0.04601743340840223,83.27775333572127,11.626110383825996,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-620TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,620.0,587.7,2.75,,,60.0,18.31,42.9,17.37,35.7,0.01232263,-0.1029171,44.8,1.5041888948116582,18.321741366107325,7.449346460079729e-12,0.14201426549327498,221.4632594759501,4.8858215996254035,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-625H,CSI Solar Co Ltd,Mono-c-Si,1,625.0,595.9,2.62,,,72.0,14.84,52.8,13.89,45.0,0.0094234,-0.12444960000000001,44.1,1.8444574108421725,14.856522703259127,5.329775403538359e-12,0.13456719400995423,120.86261727514491,5.806453116412248,-0.2714,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-625H,CSI Solar Co Ltd,Mono-c-Si,1,625.0,598.4,2.62,,,66.0,15.75,50.1,14.69,42.6,0.01059975,-0.1091178,44.4,1.6943049008427389,15.773575040007085,2.1907991390742833e-12,0.13653006706463242,91.21293351497415,5.861776808881732,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-625HP,CSI Solar Co Ltd,Mono-c-Si,1,625.0,598.4,2.62,,,66.0,15.75,50.1,14.69,42.6,0.01059975,-0.1091178,44.4,1.6943049008427389,15.773575040007085,2.1907991390742833e-12,0.13653006706463242,91.21293351497415,5.861776808881732,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-625H,CSI Solar Co Ltd,Mono-c-Si,1,625.0,594.7,2.62,,,66.0,16.14,48.6,15.11,41.4,0.00958716,-0.10240020000000001,44.1,1.696674616837556,16.158063995254967,5.695071536458112e-12,0.11552420264630839,103.21972551325486,18.38383427893737,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-625HP,CSI Solar Co Ltd,Mono-c-Si,1,625.0,594.7,2.62,,,66.0,16.14,48.6,15.11,41.4,0.00958716,-0.10240020000000001,44.1,1.696674616837556,16.158063995254967,5.695071536458112e-12,0.11552420264630839,103.21972551325486,18.38383427893737,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-625HR,CSI Solar Co Ltd,Mono-c-Si,1,625.0,592.0,2.62,,,22.0,15.62,49.9,14.49,43.2,0.0126522,-0.1358278,43.7,1.907117266460924,15.628034569511161,6.5171110486044e-11,0.044131513080851024,85.79603870490143,11.585345698748359,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-625TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,625.0,592.6,2.75,,,60.0,18.36,43.1,17.41,35.9,0.012356279999999999,-0.10339690000000001,44.8,1.5121677179883675,18.37225413536303,7.60261860987566e-12,0.1400798858589444,209.87745241858582,5.040917079603749,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS61-72TB-630H,CSI Solar Co Ltd,Mono-c-Si,1,630.0,600.8,2.62,,,72.0,14.9,53.0,13.94,45.2,0.0094615,-0.124921,44.1,1.8524057450580818,14.916592780065033,5.428346485538801e-12,0.1320656756586748,118.59245772098492,5.933706660661509,-0.2714,N,2025.7.3,6/23/2025,4.0,first_pass +CSI Solar Co Ltd CS62-66HB-630H,CSI Solar Co Ltd,Mono-c-Si,1,630.0,603.2,2.62,,,66.0,15.82,50.2,14.79,42.6,0.010646860000000001,-0.10933559999999999,44.4,1.694346421001064,15.842801695530147,2.0819736386630393e-12,0.1429207657407995,99.15957835731027,5.35968033059379,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-630HP,CSI Solar Co Ltd,Mono-c-Si,1,630.0,603.2,2.62,,,66.0,15.82,50.2,14.79,42.6,0.010646860000000001,-0.10933559999999999,44.4,1.694346421001064,15.842801695530147,2.0819736386630393e-12,0.1429207657407995,99.15957835731027,5.35968033059379,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-630H,CSI Solar Co Ltd,Mono-c-Si,1,630.0,599.6,2.62,,,66.0,16.2,48.8,15.16,41.6,0.0096228,-0.1028216,44.1,1.7045237627949181,16.2180932379272,5.79701679408327e-12,0.1133099583447665,101.45344540937376,18.52360593410191,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-630HP,CSI Solar Co Ltd,Mono-c-Si,1,630.0,599.6,2.62,,,66.0,16.2,48.8,15.16,41.6,0.0096228,-0.1028216,44.1,1.7045237627949181,16.2180932379272,5.79701679408327e-12,0.1133099583447665,101.45344540937376,18.52360593410191,-0.2825,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66TB-630HR,CSI Solar Co Ltd,Mono-c-Si,1,630.0,596.9,2.62,,,22.0,15.7,50.1,14.54,43.4,0.012717000000000001,-0.1363722,43.7,1.9170522155450633,15.708009239327177,6.744926409860306e-11,0.04155422330869906,81.4560885915001,11.857945976788205,-0.3144,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-630TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,630.0,597.4,2.75,,,60.0,18.41,43.3,17.46,36.1,0.01238993,-0.1038767,44.8,1.519756264108109,18.421985766254593,7.706137183594136e-12,0.13817069783432656,212.22861352550424,5.134016445196032,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-630MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,630.0,586.1,3.07,,,66.0,18.23,44.2,16.99,37.1,0.00968013,-0.129285,43.7,1.7588777895429857,18.250511281263204,2.1657938339410165e-10,0.1001064308093061,88.97251445924142,13.251794858261238,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS62-66HB-635H,CSI Solar Co Ltd,Mono-c-Si,1,635.0,608.1,2.62,,,66.0,15.92,50.3,14.88,42.7,0.01071416,-0.1095534,44.4,1.6981755441020652,15.942967128901628,2.1111521375804437e-12,0.14113516364543718,97.82989486535966,5.42824775783799,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-635HP,CSI Solar Co Ltd,Mono-c-Si,1,635.0,608.1,2.62,,,66.0,15.92,50.3,14.88,42.7,0.01071416,-0.1095534,44.4,1.6981755441020652,15.942967128901628,2.1111521375804437e-12,0.14113516364543718,97.82989486535966,5.42824775783799,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-635TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,635.0,602.3,2.75,,,60.0,18.46,43.5,17.5,36.3,0.01242358,-0.1043565,44.8,1.5277371935074375,18.47246727807378,7.862282417804995e-12,0.1362547014757627,201.7490728815324,5.286941527971354,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-635MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,635.0,590.9,3.07,,,66.0,18.27,44.4,17.03,37.3,0.00970137,-0.12986999999999999,43.7,1.7675155363432027,18.290013405610416,2.1918333629680212e-10,0.09816678415177253,89.61529166536305,13.340661166424294,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS62-66HB-640H,CSI Solar Co Ltd,Mono-c-Si,1,640.0,613.0,2.62,,,66.0,16.01,50.4,14.99,42.7,0.010774730000000001,-0.1097712,44.4,1.698694449128928,16.03256266836654,2.02432033678667e-12,0.14717335911136334,104.43115334280553,4.99890581266274,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-640HP,CSI Solar Co Ltd,Mono-c-Si,1,640.0,613.0,2.62,,,66.0,16.01,50.4,14.99,42.7,0.010774730000000001,-0.1097712,44.4,1.698694449128928,16.03256266836654,2.02432033678667e-12,0.14717335911136334,104.43115334280553,4.99890581266274,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-640TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,640.0,607.1,2.75,,,60.0,18.51,43.7,17.54,36.5,0.012457230000000001,-0.10483630000000001,44.8,1.5357201499196458,18.522927136765986,8.020368121978594e-12,0.1343470111678776,192.3676702720776,5.438821006020427,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-640MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,640.0,595.7,3.07,,,66.0,18.31,44.6,17.07,37.5,0.00972261,-0.130455,43.7,1.7761518366356823,18.32952188241516,2.2179221515332037e-10,0.0962367711379526,90.26257181581697,13.42855016990302,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS62-66HB-645H,CSI Solar Co Ltd,Mono-c-Si,1,645.0,617.9,2.62,,,66.0,16.13,50.4,15.07,42.8,0.010855489999999999,-0.1097712,44.4,1.7021448018181529,16.153439806385,2.1600782547009357e-12,0.1384046714207385,95.24256787318454,5.517053681231517,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-645HP,CSI Solar Co Ltd,Mono-c-Si,1,645.0,617.9,2.62,,,66.0,16.13,50.4,15.07,42.8,0.010855489999999999,-0.1097712,44.4,1.7021448018181529,16.153439806385,2.1600782547009357e-12,0.1384046714207385,95.24256787318454,5.517053681231517,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-645TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,645.0,612.0,2.75,,,60.0,18.56,43.9,17.58,36.7,0.01249088,-0.1053161,44.8,1.543704927602962,18.57336563417018,8.180375436353405e-12,0.13244776109749934,183.92172195674738,5.5897086016700595,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-645MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,645.0,600.4,3.07,,,66.0,18.35,44.8,17.11,37.7,0.009743850000000002,-0.13104,43.7,1.7847867035423286,18.36903664067214,2.2440587524030647e-10,0.09431631752003405,90.91438378108047,13.515476979543612,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS62-66HB-650H,CSI Solar Co Ltd,Mono-c-Si,1,650.0,622.8,2.62,,,66.0,16.22,50.5,15.16,42.9,0.010916059999999998,-0.109989,44.4,1.7054979503606127,16.243067683952532,2.1721470883815784e-12,0.13681917789946504,96.20415602427619,5.515513894038098,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS62-66HB-650HP,CSI Solar Co Ltd,Mono-c-Si,1,650.0,622.8,2.62,,,66.0,16.22,50.5,15.16,42.9,0.010916059999999998,-0.109989,44.4,1.7054979503606127,16.243067683952532,2.1721470883815784e-12,0.13681917789946504,96.20415602427619,5.515513894038098,-0.2448,N,2025.7.3,6/23/2025,2.0,first_pass +CSI Solar Co Ltd CS7L-650TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,650.0,616.9,2.75,,,60.0,18.61,44.1,17.62,36.9,0.012524529999999999,-0.1057959,44.8,1.5516919947676304,18.623783195344153,8.342373194278699e-12,0.13055677810035374,176.2770951865757,5.73936308824113,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-650MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,650.0,605.2,3.07,,,66.0,18.39,45.0,17.16,37.9,0.00976509,-0.131625,43.7,1.7928640259979614,18.408086037399517,2.2542000705486153e-10,0.09248003360636575,94.0342991662114,13.534068855390277,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-655TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,655.0,621.7,2.75,,,60.0,18.63,44.4,17.66,37.1,0.012537989999999999,-0.1065156,44.8,1.5603764665132398,18.642494834921763,8.083772468885748e-12,0.13464270168640077,200.75443214043295,5.449957514035354,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-655MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,655.0,610.0,3.07,,,66.0,18.43,45.2,17.2,38.1,0.00978633,-0.13221,43.7,1.8014942648687304,18.44762491231804,2.280273303924908e-10,0.09057986960045691,94.71746584332838,13.619190184484621,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7L-660TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,660.0,626.6,2.75,,,60.0,18.68,44.6,17.7,37.3,0.012571639999999999,-0.1069954,44.8,1.5683630571399612,18.692937048953947,8.24287058014108e-12,0.1327554109616518,191.68753953470113,5.598483525616593,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-660MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,660.0,614.8,3.07,,,66.0,18.47,45.4,17.24,38.3,0.00980757,-0.132795,43.7,1.8101231217516611,18.487169723073997,2.306390592727724e-10,0.08868903295013442,95.40552657497945,13.703392054629385,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-665MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,665.0,619.6,3.07,,,66.0,18.51,45.6,17.28,38.5,0.00982881,-0.13338,43.7,1.8187506267392906,18.52672040427124,2.332551037214021e-10,0.08680745694233322,96.09851735686227,13.786674783443173,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-665TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,665.0,630.0,3.03,,,66.0,18.14,46.5,17.23,38.6,0.01220822,-0.11155350000000001,44.8,1.6275838127251792,18.150115163861955,7.0347972797546446e-12,0.16174360834002374,290.0624355443497,4.465043781452366,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-670MB-AG,CSI Solar Co Ltd,Mono-c-Si,1,670.0,624.4,3.07,,,66.0,18.55,45.8,17.32,38.7,0.00985005,-0.13396499999999997,43.7,1.8273767379848223,18.56627688874087,2.358751971649567e-10,0.084935059238755,96.79647045924125,13.869092541338263,-0.39,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-670TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,670.0,634.8,3.03,,,66.0,18.19,46.7,17.27,38.8,0.01224187,-0.1120333,44.8,1.6355853606090645,18.200696709945024,7.174418619759366e-12,0.15974192175703897,271.6447937332604,4.613272612548324,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-675TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,675.0,639.7,3.03,,,66.0,18.24,46.9,17.31,39.0,0.012275519999999998,-0.11251309999999999,44.8,1.6435889975146676,18.251257139538367,7.315799795578177e-12,0.15774911244506754,255.601683721505,4.7604881557261685,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-680TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,680.0,644.5,3.03,,,66.0,18.29,47.1,17.35,39.2,0.01230917,-0.11299290000000001,44.8,1.6515946959815697,18.30179678890146,7.458946849430356e-12,0.15576511371963594,241.5016455414475,4.9067145772663725,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-685TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,685.0,649.4,3.03,,,66.0,18.34,47.3,17.39,39.4,0.012342820000000001,-0.1134727,44.8,1.659602352971556,18.352315987142273,7.603857352930947e-12,0.15378984964467118,229.01175664311515,5.052023390828776,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-690TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,690.0,654.2,3.03,,,66.0,18.39,47.5,17.43,39.6,0.01237647,-0.11395250000000001,44.8,1.6676120252078364,18.40281505023646,7.750546088418587e-12,0.15182327074224206,217.87116747575146,5.1963799032363704,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-695TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,695.0,659.1,3.03,,,66.0,18.44,47.7,17.47,39.8,0.01241012,-0.11443230000000001,44.8,1.6756236015429202,18.45329429119397,7.899009088399965e-12,0.14986530590190755,207.8724023275727,5.339857642636865,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-700TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,700.0,663.9,3.03,,,66.0,18.49,47.9,17.51,40.0,0.012443769999999998,-0.1149121,44.8,1.6836371913324788,18.50375401500524,8.049266768335913e-12,0.14791591132467524,198.84849665888902,5.482392489830118,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-705TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,705.0,668.8,3.03,,,66.0,18.54,48.1,17.55,40.2,0.012477419999999998,-0.1153919,44.8,1.691652778317637,18.554194513178643,8.20132716040196e-12,0.14597502277172192,190.6635961552414,5.623989445743913,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-710TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,710.0,673.7,3.03,,,66.0,18.59,48.3,17.59,40.4,0.012511070000000001,-0.1158717,44.8,1.6996702963636188,18.60461608531842,8.355189711769621e-12,0.14404258087994276,183.20579868611992,5.764701572598982,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-715TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,715.0,678.5,3.03,,,66.0,18.64,48.5,17.63,40.6,0.01254472,-0.1163515,44.8,1.7076898560702622,18.65501901095361,8.510876604065853e-12,0.14211854304287644,176.3824299735956,5.90445746147024,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-720TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,720.0,683.4,3.03,,,66.0,18.69,48.7,17.67,40.8,0.01257837,-0.11683130000000001,44.8,1.7157110643361695,18.70540358451595,8.66834723120829e-12,0.1402028057380486,170.11562742139415,6.043515164329765,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-725TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,725.0,688.2,3.03,,,66.0,18.74,48.9,17.71,41.0,0.012612019999999998,-0.1173111,44.8,1.7237345408202158,18.755770052527804,8.827688414868774e-12,0.13829538124311352,164.34031813787087,6.18147087281277,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CSI Solar Co Ltd CS7N-730TB-AG,CSI Solar Co Ltd,Mono-c-Si,1,730.0,693.1,3.03,,,66.0,18.79,49.1,17.75,41.2,0.01264567,-0.11779090000000002,44.8,1.7317597598593781,18.806118706038877,8.988841057541893e-12,0.13639616132831994,159.00059656721294,6.318671809420071,-0.2855,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT450-108TNB10,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,450.0,432.3,1.95,,,54.0,14.55,39.53,13.77,32.68,0.006402000000000001,-0.12254300000000001,42.3,1.3044332671056458,14.56648875322592,9.895908133279275e-13,0.19544630167164137,172.4656589660574,-29.916310076077444,-0.25,N,2025.7.3,6/23/2025,4.0,first_pass +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT530-108PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,530.0,496.2,2.56,,,54.0,18.28,37.0,17.27,30.7,0.0071292000000000005,-0.09139,45.57,1.3211472323563864,18.296500200250186,1.2392868570080718e-11,0.12553697948536485,139.0780692515199,6.625061047614859,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT535-108PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,535.0,501.0,2.56,,,54.0,18.33,37.2,17.31,30.9,0.0071487,-0.09188400000000001,45.57,1.3292583892060745,18.34692594059469,1.2675753541892279e-11,0.12361152683881023,133.8654878198078,6.800163420670148,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT540-108PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,540.0,505.8,2.56,,,54.0,18.38,37.5,17.36,31.1,0.0071682,-0.092625,45.57,1.3388486003985849,18.397036195031998,1.2417929351610796e-11,0.12751500347219769,137.57331185013507,6.5960574117895625,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT545-108PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,545.0,510.6,2.56,,,54.0,18.45,37.7,17.42,31.3,0.0071955,-0.09311900000000001,45.57,1.3469225988388267,18.46739308981451,1.2703013487826275e-11,0.12545951528765825,133.0832008273895,6.762768969359112,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT550-108PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,550.0,515.4,2.56,,,54.0,18.49,37.9,17.46,31.5,0.007211099999999999,-0.093613,45.57,1.3546990909609817,18.507048067737546,1.289822572239054e-11,0.12363107662438864,134.087842098071,6.876692916848264,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT595-144TNB10,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,595.0,574.0,2.58,,,72.0,14.24,52.85,13.6,43.85,0.0068352000000000005,-0.142695,41.9,1.6965796317717183,14.245971527330973,4.1920527779151145e-13,0.26095257969731817,622.2804539124047,-25.097535387887692,-0.23,N,2025.7.3,6/23/2025,4.0,first_pass +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT600-144TNB10,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,600.0,572.9,2.58,,,72.0,14.3,53.05,13.5,44.45,0.0065780000000000005,-0.132625,42.2,1.8415312924066622,14.313997936839286,4.335156195952165e-12,0.20388435029352936,208.28399567660333,-1.475651325114602,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT650-132PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,650.0,608.7,3.11,,,66.0,18.35,45.2,17.34,37.5,0.0071565000000000005,-0.11164400000000001,45.57,1.6136972814118917,18.36626813583175,1.239092052988753e-11,0.15302959787606193,172.61308610663184,6.588571287457686,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT655-132PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,655.0,613.5,3.11,,,66.0,18.39,45.4,17.38,37.7,0.007172100000000001,-0.112138,45.57,1.6214549832679332,18.40597661492634,1.2551903582905201e-11,0.15113320416262233,173.9629857426621,6.6825550312557604,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT660-132PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,660.0,618.3,3.11,,,66.0,18.44,45.6,17.42,37.9,0.0071916,-0.112632,45.57,1.629621092673624,18.456436244331364,1.2801906974191709e-11,0.14914808821228442,167.3308512957826,6.83302505447023,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT665-132PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,665.0,623.1,3.11,,,66.0,18.48,45.8,17.46,38.1,0.0072072,-0.11312599999999999,45.57,1.6373789164883839,18.496139063069602,1.2965035553458731e-11,0.14727013287732316,168.63135445015863,6.924330890996401,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT670-132PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,670.0,627.9,3.11,,,66.0,18.51,46.0,17.5,38.3,0.0072189,-0.11362,45.57,1.6447239749026767,18.525120895972712,1.3038291126375983e-11,0.1454997594686692,178.11117557611396,6.956616184087609,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET CWT675-132PMB12,CW ENERJ M HEND SL K T CARET VE SANAY ANON M RKET ,Mono-c-Si,1,675.0,632.8,3.11,,,66.0,18.56,46.2,17.54,38.5,0.0072384,-0.11411400000000001,45.57,1.652891671342021,18.575554569295196,1.329282945986803e-11,0.14354125994030736,171.276088914242,7.104177882187878,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +DE SOLAR(S) PTE LTD DE420-108BG-182S-N/BB,DE SOLAR(S) PTE LTD,Mono-c-Si,0,420.0,398.3,1.95,,,54.0,13.58,39.7,13.28,31.6,0.004753,-0.09528,43.8,1.3368842435041464,13.580004074838463,1.7223709340309733e-12,0.25889825329855787,862821.2565735326,-4.402189169946739,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +DE SOLAR(S) PTE LTD DE425-108BG-182S-N/BB,DE SOLAR(S) PTE LTD,Mono-c-Si,0,425.0,403.1,1.95,,,54.0,13.68,39.8,13.38,31.8,0.004788000000000001,-0.09552,43.8,1.3422862797895116,13.680004007375741,1.814935868222668e-12,0.25098990622795325,856810.1746372904,-4.043126014314502,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +DE SOLAR(S) PTE LTD DE430-108BG-182S-N/BB,DE SOLAR(S) PTE LTD,Mono-c-Si,0,430.0,408.0,1.95,,,54.0,13.78,40.0,13.48,31.9,0.004823000000000001,-0.096,43.8,1.3481640943609523,13.780004015583689,1.7936588377179825e-12,0.2511898691194234,861995.4429561679,-4.19543085100026,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +DE SOLAR(S) PTE LTD DE435-108BG-182S-N/BB,DE SOLAR(S) PTE LTD,Mono-c-Si,0,435.0,412.9,1.95,,,54.0,13.88,40.1,13.58,32.0,0.004858,-0.09624,43.8,1.3519117219065209,13.880004107226712,1.821694163389201e-12,0.25290039167895106,854658.6034825091,-4.129357024483465,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +DE SOLAR(S) PTE LTD DE440-108BG-182S-N/BB,DE SOLAR(S) PTE LTD,Mono-c-Si,0,440.0,417.7,1.95,,,54.0,13.98,40.2,13.68,32.2,0.004893000000000001,-0.09648,43.8,1.3573908365848297,13.98000382219366,1.9213048718982297e-12,0.23558435605959388,861674.3476584363,-3.761073283936499,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW,DE SOLAR(S) PTE LTD,Mono-c-Si,0,570.0,542.9,2.58,,,72.0,13.91,51.2,13.4,42.5,0.0045903,-0.124416,43.2,1.7143303488161368,13.910003420943005,1.4884514911446636e-12,0.22629528725630238,920147.971275759,-6.887574542765899,-0.282,N,2025.7.3,6/23/2025,2.0,first_pass +DE SOLAR(S) PTE LTD DE575-144BG-182S-N/WW,DE SOLAR(S) PTE LTD,Mono-c-Si,0,575.0,547.7,2.58,,,72.0,13.98,51.3,13.47,42.7,0.0046134,-0.124659,43.2,1.745567810689548,13.98000618095752,2.4107171859314766e-12,0.2290465387866942,518055.19984990335,-3.1170231744133186,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +DE SOLAR(S) PTE LTD DE580-144BG-182S-N/WW,DE SOLAR(S) PTE LTD,Mono-c-Si,0,580.0,552.6,2.58,,,72.0,14.05,51.5,13.54,42.8,0.004636500000000001,-0.125145,43.2,1.7526603083625376,14.050006352319242,2.43448239597527e-12,0.23409116262787377,517761.7311495633,-3.0783467967440714,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW,DE SOLAR(S) PTE LTD,Mono-c-Si,0,585.0,557.5,2.58,,,72.0,14.13,51.6,13.61,43.0,0.0046629,-0.125388,43.2,1.7302460406005131,14.130124132698729,1.5790781686628576e-12,0.22819225054049697,25975.081035313957,-6.549044723951956,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +DE SOLAR(S) PTE LTD DE590-144BG-182S-N/WW,DE SOLAR(S) PTE LTD,Mono-c-Si,0,590.0,562.3,2.58,,,72.0,14.19,51.8,13.68,43.1,0.004682700000000001,-0.125874,43.2,1.736423409542374,14.190083781192358,1.5715122432544212e-12,0.23342598161588857,39535.308988999925,-6.6196942360049125,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +DE SOLAR(S) PTE LTD DE595-144BG-182S-N/WW,DE SOLAR(S) PTE LTD,Mono-c-Si,0,595.0,567.2,2.58,,,72.0,14.26,51.9,13.75,43.3,0.0047058000000000004,-0.126117,43.2,1.7418478575226488,14.260003150109283,1.6364552986616821e-12,0.20349777358425886,921201.0138406261,-6.342458477160937,-0.282,N,2025.7.3,6/23/2025,2.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860F 320W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,320.0,297.2,1.61,,,60.0,10.2,40.2,9.64,33.2,0.0043452,-0.10488180000000001,45.4,1.5014358735017896,10.207212014354527,2.3769525422528112e-11,0.24693442840551408,349.24098281731733,11.492148477624658,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860F 325W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,325.0,302.0,1.61,,,60.0,10.25,40.4,9.71,33.5,0.004366500000000001,-0.1054036,45.4,1.5102952337446764,10.255263837468302,2.453945648111951e-11,0.23108787812535816,449.9855166600984,11.726779621868467,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860W 325W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,325.0,300.6,1.59,,,60.0,10.3,40.4,9.68,33.6,0.0042951000000000005,-0.10633279999999999,46.5,1.5246327530270136,10.310561960017328,3.141333088694714e-11,0.21604364910490112,210.68528985014117,12.981291885966733,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860F 330W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,330.0,306.8,1.61,,,60.0,10.3,40.6,9.77,33.8,0.0043878,-0.10592540000000002,45.4,1.51988140994291,10.304242125104457,2.5620784726570377e-11,0.2153951636632566,522.9855743864491,12.068661305905843,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860W 330W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,330.0,305.3,1.59,,,60.0,10.39,40.6,9.77,33.8,0.0043326300000000005,-0.1068592,46.5,1.532546458798262,10.400124571290572,3.190673005750645e-11,0.21131382281172012,216.85368969397052,13.04203058413566,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,335.0,311.5,1.61,,,60.0,10.35,40.8,9.83,34.1,0.0044091,-0.1064472,45.4,1.5294523749687314,10.353323041947341,2.6729414795829216e-11,0.1999080367697668,622.6368072053476,12.40480072066728,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860W 335W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,335.0,310.1,1.59,,,60.0,10.48,40.7,9.86,34.0,0.0043701600000000005,-0.1071224,46.5,1.53862168540507,10.489347327495242,3.3493752959665756e-11,0.19642372453177556,220.22558368702684,13.406002204141794,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860F 340W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,340.0,316.3,1.61,,,60.0,10.4,41.0,9.89,34.4,0.0044304,-0.10696900000000002,45.4,1.5390084939065602,10.402504072107972,2.786539341408003e-11,0.18462235711983113,766.7800623513647,12.735338461187911,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860W 340W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,340.0,314.9,1.59,,,60.0,10.55,41.1,9.95,34.2,0.004399350000000001,-0.1081752,46.5,1.5487854677847306,10.558261686877058,3.1080544879224266e-11,0.21284993011988237,271.80487759266975,12.649785066033127,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M860W 345W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,345.0,319.6,1.59,,,60.0,10.56,41.2,10.0,34.5,0.004403520000000001,-0.1084384,46.5,1.5544643157435716,10.565056221425735,3.227573388287106e-11,0.18859094624308076,393.8752395720966,12.96882489252699,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760B 350W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,350.0,326.3,1.83,,,40.0,11.15,40.1,10.42,33.6,0.0059095,-0.11268100000000002,44.2,1.5358103603622737,11.163295031603257,4.9785459819574983e-11,0.1673037797584847,140.31084818128528,8.965951742959888,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760F 350W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,350.0,323.6,1.78,,,60.0,11.15,40.1,10.45,33.5,0.00687955,-0.1253125,45.4,1.5910237174140252,11.16029201385629,1.2388199462437848e-10,0.16621527068898326,180.07168889793877,5.250156657786078,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760W 350W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,350.0,322.7,1.81,,,60.0,11.15,40.1,10.42,33.6,0.0061771,-0.11171860000000002,46.0,1.573145351198383,11.16207484717893,9.261981486923336e-11,0.15942448526437147,147.2137090373453,15.52492285440527,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760B 355W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,355.0,331.1,1.83,,,40.0,11.25,40.3,10.51,33.8,0.0059625,-0.113243,44.2,1.5445127757747685,11.263361144128975,5.1100556853290356e-11,0.16303521403095028,137.27463427753585,9.118826409166019,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760F 355W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,355.0,328.4,1.78,,,60.0,11.24,40.3,10.54,33.7,0.00693508,-0.12593749999999998,45.4,1.5993674020210316,11.249860885514387,1.2575596667942346e-10,0.16215590670306437,184.83456055632814,5.3078096364956355,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760W 355W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,355.0,327.5,1.81,,,60.0,11.25,40.3,10.51,33.8,0.0062325,-0.1122758,46.0,1.5820674121480922,11.262132755583469,9.503872526927639e-11,0.15517143889465929,143.88147054481757,15.684015933070386,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,360.0,335.9,1.83,,,40.0,11.35,40.5,10.59,34.0,0.0060155,-0.11380500000000002,44.2,1.5539682011737326,11.363976164781905,5.304380624766523e-11,0.15870209830678145,128.88148207493782,9.375810810236858,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760F 360W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,360.0,333.1,1.78,,,60.0,11.33,40.5,10.62,33.9,0.0069906099999999995,-0.12656250000000002,45.4,1.6085137204875501,11.34000623678336,1.2911096058342643e-10,0.15801823389932998,178.92307309535389,5.465899455310446,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760W 360W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,360.0,332.2,1.81,,,60.0,11.35,40.5,10.59,34.0,0.0062879,-0.11283300000000002,46.0,1.591767334203999,11.36271125514716,9.860490354710674e-11,0.15083926337318254,134.68580758691422,15.951533243766043,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760B 365W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,365.0,340.7,1.83,,,40.0,11.43,40.7,10.68,34.2,0.0060579,-0.11436700000000002,44.2,1.5612619148644942,11.442953832404886,5.316537385698562e-11,0.15510751240870377,136.8613415831665,9.328389567386376,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760F 365W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,365.0,337.9,1.78,,,60.0,11.41,40.7,10.71,34.1,0.00703997,-0.1271875,45.4,1.6161070898489036,11.419061113989244,1.2951857430795875e-10,0.15436771205725558,194.3840068754955,5.427924740171898,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760W 365W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,365.0,337.0,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0063322199999999995,-0.11339020000000001,46.0,1.5992338744726025,11.441735753316635,9.883882152273302e-11,0.14727260206241186,143.43568615318978,15.902164143097854,-0.3798,N,2025.7.3,6/23/2025,4.0,bootstrapping +Dehui Solar Power (Vietnam) CoLtd DH-M760B 370W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,370.0,345.5,1.83,,,40.0,11.52,40.9,10.76,34.4,0.0061056,-0.114929,44.2,1.5663711906150062,11.533137654869922,5.1313585984221295e-11,0.15191721746413944,133.211473171767,8.949116749615767,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760F 370W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,370.0,342.6,1.78,,,60.0,11.5,40.9,10.79,34.3,0.0070955,-0.1278125,45.4,1.6252516759894493,11.509203377706894,1.3291880994183492e-10,0.15035429429508795,187.8738958913682,5.583665260789159,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760W 370W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,370.0,341.7,1.81,,,60.0,11.52,40.9,10.76,34.4,0.006382079999999999,-0.1139474,46.0,1.6082045160669267,11.531790121453808,1.0133077111036836e-10,0.14333958942289313,140.0555627907442,16.063890655763746,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760B 375W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,375.0,350.3,1.83,,,40.0,11.6,41.1,10.84,34.6,0.006148,-0.11549100000000002,44.2,1.5780593666970166,11.612567083772003,5.5264497570365347e-11,0.14754752309515376,136.19319428997485,9.54054869590866,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760F 375W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,375.0,347.4,1.78,,,60.0,11.59,41.1,10.87,34.5,0.00715103,-0.1284375,45.4,1.6343955786653208,11.599330436057866,1.3637125044970799e-10,0.14640039183349143,181.85437165646778,5.73781088126199,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M760W 375W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,375.0,346.5,1.81,,,60.0,11.6,41.1,10.84,34.6,0.0064264,-0.11450460000000001,46.0,1.518831389118631,11.614566272547847,1.9981205736965716e-11,0.15974444296484103,127.21412004161442,1.7295383138266751,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154T 385W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,385.0,358.8,1.93,,,54.0,13.52,36.72,12.65,30.44,0.00492128,-0.0910656,46.93,1.3058689371318561,13.542967419534579,8.089920308786613e-12,0.17251632884843254,101.55345357440883,5.197381991328475,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154B 390W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,390.0,358.9,1.93,,,54.0,13.5,36.54,12.82,30.42,0.00621,-0.10077732,47.45,1.3871685617383966,13.50387644263667,4.877318240501822e-11,0.1445449715117158,503.3886345508158,9.170365584854244,-0.3685,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154T 390W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,390.0,363.6,1.93,,,54.0,13.61,36.85,12.73,30.64,0.00495404,-0.091388,46.93,1.312638659737849,13.63250657428262,8.521255938927754e-12,0.16367845627546268,98.9783592000542,5.590154924968769,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154W 390W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,390.0,360.9,1.93,,,54.0,13.6,36.81,12.83,30.4,0.005168,-0.09762012,46.73,1.3650703967035729,13.612014426481453,2.6109433481441903e-11,0.17141156934307517,194.03317501761623,8.037213270621239,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872F 390W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,390.0,362.3,1.95,,,72.0,10.25,48.5,9.71,40.2,0.004366500000000001,-0.1265365,45.4,1.8127241151220816,10.255277427169286,2.4404011992146344e-11,0.2793861044012475,542.633281197194,11.676601583687079,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154B 395W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,395.0,363.7,1.93,,,54.0,13.55,36.74,12.88,30.63,0.006233000000000001,-0.10132892,47.45,1.388484635081727,13.553239169278461,4.349188301142138e-11,0.1421019230024388,594.436711626413,8.129228246898078,-0.3685,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154T 395W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,395.0,368.4,1.93,,,54.0,13.7,36.98,12.81,30.84,0.0049868,-0.09171039999999998,46.93,1.3040765521231448,13.722805572685473,6.449381551248987e-12,0.15766160406890245,94.71211304900056,3.162425431840026,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154W 395W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,395.0,365.6,1.93,,,54.0,13.71,36.94,12.92,30.57,0.0052098,-0.09796488,46.73,1.3720222073205768,13.722971297602829,2.740637545253245e-11,0.1650143476210528,174.41175088341876,8.39673383080809,-0.3571,N,2025.7.3,6/23/2025,4.0,bootstrapping +Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,395.0,367.1,1.95,,,72.0,10.29,48.7,9.76,40.5,0.004383539999999999,-0.1270583,45.4,1.8221712137434154,10.294300844472021,2.5247516698559718e-11,0.2637231459080289,630.9717181712844,11.944328870797486,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,395.0,365.4,1.91,,,72.0,10.37,48.7,9.86,40.1,0.00432429,-0.1281784,46.5,1.818309850536994,10.37220443957253,2.4137825539809313e-11,0.306989980897316,1444.124986443158,10.483863418612984,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154B 400W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,400.0,368.4,1.93,,,54.0,13.6,36.94,12.96,30.84,0.006256,-0.10188052,47.45,1.3990768209752007,13.601014010666006,4.636628661985415e-11,0.13804660876934255,1851.4934653405066,8.646433137292545,-0.3685,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154T 400W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,400.0,373.2,1.93,,,54.0,13.79,37.07,12.9,31.01,0.00501956,-0.0919336,46.93,1.3243294691228409,13.810662308014873,9.365098184682618e-12,0.14592235016731542,97.38841917730565,6.294985256745999,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154W 400W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,400.0,370.4,1.93,,,54.0,13.79,37.03,13.03,30.71,0.0052401999999999995,-0.09820356,46.73,1.3750949874877019,13.800074199055606,2.7501035481798503e-11,0.15878127862195013,217.34670915385206,8.364904316448886,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872F 400W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,400.0,371.8,1.95,,,72.0,10.33,48.9,9.81,40.8,0.00440058,-0.1275801,45.4,1.8316046053372685,10.33341025036577,2.610660155584484e-11,0.24823217369455688,751.9208677251013,12.208062661174639,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872W 400W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,400.0,370.2,1.91,,,72.0,10.45,49.0,9.93,40.3,0.00435765,-0.128968,46.5,1.8289600311250924,10.45270740739021,2.4114173226645323e-11,0.311947435085346,1204.0488850588736,10.408748611921862,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154B 405W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,405.0,373.2,1.93,,,54.0,13.65,37.14,13.05,31.03,0.006279000000000001,-0.10243212,47.45,1.3667244991918044,13.65032419915793,2.6433930699181195e-11,0.11847373581464207,4988.189367437276,58.00892754362807,-0.3685,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154T 405W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,405.0,378.0,1.93,,,54.0,13.87,37.23,12.98,31.21,0.00504868,-0.09233039999999999,46.93,1.3311810673366349,13.889706380776266,9.649688864278785e-12,0.1399040369790604,98.46907043419202,6.503665544100626,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154W 405W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,405.0,375.2,1.93,,,54.0,13.86,37.15,13.13,30.86,0.0052668,-0.09852179999999999,46.73,1.3789845927791873,13.867428896432132,2.7415137575428388e-11,0.15418972274561438,287.6698586381442,8.282130965200185,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872F 405W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,405.0,376.6,1.95,,,72.0,10.37,49.1,9.86,41.1,0.00441762,-0.12810190000000002,45.4,1.8343666740226268,10.370006261875039,2.460410518378827e-11,0.23433319723697488,388072.52043026243,11.443974996866375,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872W 405W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,405.0,375.0,1.91,,,72.0,10.52,49.2,10.0,40.5,0.00438684,-0.1294944,46.5,1.8369371889036124,10.522451956209933,2.4465477950495426e-11,0.307057094349389,1317.4137345099691,10.47708957243731,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154B 410W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,410.0,377.9,1.93,,,54.0,13.7,37.34,13.12,31.23,0.0063019999999999994,-0.10298372000000001,47.45,1.3977265110324923,13.700003453745213,3.424706468406776e-11,0.1364294241249443,541190.8081599174,5.949748848330725,-0.3685,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154T 410W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,410.0,382.8,1.93,,,54.0,13.95,37.32,13.04,31.45,0.0050777999999999995,-0.09255360000000001,46.93,1.338581206333317,13.968863507946907,1.0572372673100285e-11,0.1249391643644218,92.39539914054541,7.256759079870228,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,410.0,379.9,1.93,,,54.0,13.94,37.23,13.22,31.03,0.005297199999999999,-0.09873395999999998,46.73,1.3835731033149834,13.946268868831952,2.8483137380487656e-11,0.1446860603969464,321.7364673293911,8.563276882364033,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872F 410W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,410.0,381.4,1.95,,,72.0,10.41,49.3,9.91,41.4,0.00443466,-0.1286237,45.4,1.8504313824074166,10.411879461597461,2.787133610556779e-11,0.2177546142816728,1206.1037153092027,12.723887604395397,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,410.0,379.7,1.91,,,72.0,10.59,49.4,10.08,40.7,0.00441603,-0.1300208,46.5,1.8440511179566423,10.591351256342273,2.453848904446568e-11,0.30228053625110024,2369.0183075416217,10.438737825708738,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M154B 415W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,415.0,382.7,1.93,,,54.0,14.02,37.38,13.31,31.19,0.0064491999999999996,-0.10309404,47.45,1.4209147544071086,14.024262162619536,5.2396923274348986e-11,0.1362418393331919,448.15527359138207,9.471525848771888,-0.3685,N,2025.7.3,6/23/2025,4.0,bootstrapping +Dehui Solar Power (Vietnam) CoLtd DH-M154W 415W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,415.0,384.7,1.93,,,54.0,14.02,37.38,13.31,31.19,0.005327599999999999,-0.09913176,46.73,1.3892249023638876,14.025280845986826,2.8722234554478926e-11,0.14148410270952197,375.6229891721826,8.582029243737379,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872W 415W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,415.0,384.5,1.91,,,72.0,10.66,49.6,10.15,40.9,0.00444522,-0.1305472,46.5,1.8520334981632163,10.661120877697607,2.4893484319959396e-11,0.29752850910555584,2829.6165973186226,10.507038511256006,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M872W 420W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,420.0,389.3,1.91,,,72.0,10.76,49.7,10.25,41.0,0.00448692,-0.13081040000000002,46.5,1.8557595887264744,10.760755793791173,2.5136835390568886e-11,0.2934094699472239,4177.179529533504,10.50857399032459,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772F 425W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,425.0,393.1,2.14,,,72.0,11.22,48.7,10.52,40.4,0.00692274,-0.1521875,45.4,1.9243543371133889,11.23133025206831,1.1256108861732063e-10,0.23213724293860177,229.87837200596874,4.381894191795659,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772W 425W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,425.0,392.3,2.12,,,72.0,11.23,48.3,10.5,40.5,0.00622142,-0.1345638,46.0,1.8419806682484499,11.243121654989766,4.4853979415610807e-11,0.19866167740592822,170.02204805620443,8.894089667497072,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772F 430W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,430.0,397.8,2.14,,,72.0,11.3,48.9,10.6,40.6,0.0069721,-0.1528125,45.4,1.9326756634124558,11.310928284393885,1.1404038928125613e-10,0.2277652154600721,235.51244795616583,4.430655489224259,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772W 430W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,430.0,397.0,2.12,,,72.0,11.19,49.2,10.6,40.6,0.00619926,-0.13707120000000003,46.0,1.8928506328394044,11.190008032223083,5.759802713363736e-11,0.2671157720234987,372139.56764060614,11.060499713280672,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160T 435W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,435.0,402.6,2.14,,,60.0,13.66,41.02,12.91,33.76,0.00618798,-0.11231276000000001,46.79,1.5278901232515902,13.66996049091296,2.959714401253901e-11,0.19886504217960363,272.72717161247715,5.547034442891117,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,435.0,402.6,2.14,,,72.0,11.36,49.1,10.67,40.8,0.007009119999999999,-0.1534375,45.4,1.9158700165796523,11.360008535834739,8.418886219753073e-11,0.2285194969675685,304136.0596349038,1.8041108343847618,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,435.0,401.8,2.12,,,72.0,11.26,49.4,10.67,40.8,0.00623804,-0.1376284,46.0,1.9099027953982157,11.264092436989776,6.545271689482414e-11,0.2611435229396352,718.5147218072802,12.177878922324936,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160B 440W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,440.0,407.5,2.14,,,60.0,13.7,40.97,12.96,33.95,0.008261099999999999,-0.10582551,47.31,1.4828249679396208,13.710288788127322,1.3562559724868262e-11,0.18567000493275848,247.2282499540098,4.825216937959278,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160T 440W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,440.0,407.4,2.14,,,60.0,13.71,41.11,13.01,33.89,0.00621063,-0.11255918,46.79,1.5295634660032462,13.715410167170413,2.897599348701896e-11,0.1937344001185238,490.9457709284508,5.318195824614922,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160W 440W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,440.0,408.5,2.14,,,60.0,13.7,40.97,12.96,33.95,0.006836299999999999,-0.10607133,46.85,1.5108763508022927,13.709240323935967,2.2672937364150015e-11,0.18087693971732882,268.1740010474318,9.190299775805084,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772F 440W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,440.0,407.3,2.14,,,72.0,11.45,49.3,10.74,41.0,0.00706465,-0.1540625,45.4,1.95033262365469,11.460842406593043,1.1832855635606487e-10,0.2192564944222948,231.54333048183614,4.63178500987107,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772W 440W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,440.0,406.6,2.12,,,72.0,11.33,49.6,10.74,41.0,0.00627682,-0.13818560000000002,46.0,1.9181787315679284,11.333833649164522,6.636503042647504e-11,0.2568537884106585,759.1079616257376,12.246040300477722,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160B 445W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,445.0,412.2,2.14,,,60.0,13.77,41.08,13.05,34.1,0.00830331,-0.10610963999999999,47.31,1.5361166345286437,13.776617960953182,3.321011560288666e-11,0.17176487350188965,357.39140137816895,12.694142580137077,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160W 445W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,445.0,413.3,2.14,,,60.0,13.77,41.08,13.05,34.1,0.00687123,-0.10635612000000001,46.85,1.514937322973964,13.777329463675533,2.283557009517279e-11,0.17533995541602146,329.41443410124185,9.201097219645106,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772F 445W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,445.0,412.1,2.14,,,72.0,11.52,49.5,10.81,41.2,0.00710784,-0.1546875,45.4,1.9587140876399092,11.530486946512312,1.1982241125140214e-10,0.21524693804334077,236.45060032443345,4.685119371677367,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772W 445W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,445.0,411.3,2.12,,,72.0,11.4,49.8,10.81,41.2,0.0063156,-0.1387428,46.0,1.9264420399273052,11.403581888556193,6.727155677440849e-11,0.25262248620091615,804.0160442371421,12.312110025583475,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160B 450W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,450.0,417.0,2.14,,,60.0,13.83,41.15,13.15,34.22,0.00833949,-0.10629044999999998,47.31,1.5377411608385259,13.833441199532558,3.2904619957779767e-11,0.16607656483870786,667.4530054479694,12.55608979223148,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160T 450W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,450.0,416.9,2.14,,,60.0,13.86,41.3,13.2,34.15,0.00627858,-0.11307939999999998,46.79,1.5363597374121933,13.861627834044949,2.9268531919700025e-11,0.1836171827636619,1563.386856134844,5.2967569032789115,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160W 450W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,450.0,418.1,2.14,,,60.0,13.83,41.15,13.15,34.22,0.00690117,-0.10653735,46.85,1.5165409210992122,13.834073802504342,2.2620561793358046e-11,0.16963008412690683,575.8708500613857,9.064807881445654,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772F 450W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,450.0,416.9,2.14,,,72.0,11.58,49.6,10.87,41.4,0.007144859999999999,-0.15500000000000003,45.4,1.9653738386528081,11.589832309591014,1.2472102459577033e-10,0.20212800908067455,238.0562157327914,4.98011293526294,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M772W 450W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,450.0,416.1,2.12,,,72.0,11.47,50.0,10.88,41.4,0.006354380000000001,-0.1393,46.0,1.9347057015998548,11.473336757338846,6.818380812434504e-11,0.2484459122756409,854.0251872127116,12.377680209828018,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160B 455W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,455.0,421.8,2.14,,,60.0,13.9,41.28,13.27,34.29,0.0083817,-0.10662623999999998,47.31,1.5021019635484079,13.90047501890943,1.6133137743678486e-11,0.17539301581990452,5132.349909369547,6.156259513391744,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160T 455W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,455.0,421.7,2.14,,,60.0,13.92,41.51,13.27,34.34,0.00630576,-0.11365437999999999,46.79,1.5438351790636038,13.920635804687537,2.9255309929775027e-11,0.18237458130757148,3992.8196590586194,5.252091980533677,-0.3555,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160W 455W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,455.0,422.8,2.14,,,60.0,13.9,41.28,13.27,34.29,0.006936100000000001,-0.10687392000000001,46.85,1.502096575084042,13.900475170834712,1.613154458633003e-11,0.1753939151256184,5130.735261704448,6.047809288657064,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160B 460W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,460.0,426.5,2.14,,,60.0,13.99,41.45,13.37,34.41,0.00843597,-0.10706535,47.31,1.5461871554003053,13.990002324538795,3.186413002606734e-11,0.1661491562620453,999999.8332526372,12.142068091342024,-0.3465,N,2025.7.3,6/23/2025,2.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M160W 460W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,460.0,427.6,2.14,,,60.0,13.99,41.45,13.37,34.41,0.00698101,-0.10731405000000002,46.85,1.5240581527597694,13.990002435201758,2.159012800687927e-11,0.1740610921988705,999999.5061501015,8.532497268526969,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172T 525W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,525.0,489.5,2.56,,,72.0,13.65,49.16,12.81,40.97,0.0087633,-0.13130636,46.26,1.833333759111833,13.665676796475406,3.026379916494541e-11,0.19497971249833707,169.77148970472953,8.199322915855104,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172B 530W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,530.0,495.0,2.56,,,72.0,13.71,49.25,12.91,41.06,0.00882924,-0.12647399999999998,47.08,1.792556745789633,13.723955339776895,1.5753501996600216e-11,0.2005897205111392,197.06328405793352,6.699132706049001,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172T 530W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,530.0,494.3,2.56,,,72.0,13.71,49.28,12.89,41.12,0.008801819999999998,-0.13162688,46.26,1.8373017728598289,13.723837824388315,3.0234559207167957e-11,0.19030333723357315,188.5452697123401,8.145202644149391,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172W 530W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,530.0,497.3,2.56,,,72.0,13.71,49.25,12.91,41.06,0.007389690000000001,-0.129429,46.54,1.7496068583595727,13.725403925265818,8.016653093252396e-12,0.20805574957881343,185.17645882228192,-1.217404015138596,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172B 535W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,535.0,499.8,2.56,,,72.0,13.79,49.38,12.99,41.18,0.00888076,-0.12680783999999998,47.08,1.7972348990023737,13.803647331192252,1.5838738073992184e-11,0.19895314266500375,201.03299441349753,6.694072677845646,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172T 535W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,535.0,499.1,2.56,,,72.0,13.79,49.41,12.97,41.25,0.008853179999999999,-0.13197411,46.26,1.842308624204308,13.803485473497654,3.049365562735971e-11,0.1878235223886605,192.06492025928566,8.167780374835635,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172W 535W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,535.0,502.1,2.56,,,72.0,13.79,49.38,12.99,41.18,0.00743281,-0.12977064,46.54,1.7541731119700745,13.805087518642464,8.059886952931876e-12,0.20639343947297337,188.64371278118395,-1.2223097185253573,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172B 540W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,540.0,504.6,2.56,,,72.0,13.85,49.51,13.07,41.32,0.008919400000000001,-0.12714167999999998,47.08,1.8011173834013186,13.861903002163135,1.573498724975953e-11,0.19597362990263936,228.02942885223533,6.591826447928315,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172T 540W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,540.0,503.9,2.56,,,72.0,13.86,49.53,13.05,41.39,0.008898119999999999,-0.13229463,46.26,1.8467129851665167,13.872417651939136,3.065363894855328e-11,0.18392251353428216,205.28567387397564,8.165183643007538,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172W 540W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,540.0,506.9,2.56,,,72.0,13.85,49.51,13.07,41.32,0.007465150000000001,-0.13011228,46.54,1.7579668804823976,13.863275468403451,8.005067291061843e-12,0.20338470416180207,212.18672469143624,-1.3196969447981188,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172B 545W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,545.0,509.4,2.56,,,72.0,13.93,49.64,13.15,41.46,0.00897092,-0.12747551999999998,47.08,1.8062375855225348,13.941536435476559,1.592557562328641e-11,0.19263985711559276,232.60852346989188,6.645383765121372,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172T 545W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,1,545.0,508.7,2.56,,,72.0,13.93,49.68,13.12,41.55,0.00894306,-0.13269528,46.26,1.852813044947977,13.94205505714641,3.104447189681905e-11,0.18054575562992564,208.6263357782924,8.23133773269307,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172W 545W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,545.0,511.7,2.56,,,72.0,13.93,49.64,13.15,41.46,0.007508270000000001,-0.13045392,46.54,1.7629622414351291,13.942892822281111,8.102933836801266e-12,0.20003065096201308,216.12234415099903,-1.2690675727615144,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172B 550W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,550.0,514.2,2.56,,,72.0,14.0,49.77,13.23,41.59,0.009016000000000001,-0.12780935999999998,47.08,1.8105299750727781,14.01055479504264,1.591843758339217e-11,0.19040449132064963,252.55468156882594,6.593624917926939,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Dehui Solar Power (Vietnam) CoLtd DH-M172W 550W,Dehui Solar Power (Vietnam) CoLtd,Mono-c-Si,0,550.0,516.5,2.56,,,72.0,14.0,49.77,13.23,41.59,0.0075460000000000015,-0.13079556,46.54,1.7671538954608879,14.01187325064346,8.09823584021768e-12,0.19776867995410008,233.193215469872,-1.3184194471876907,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-270W,DEHUI SOLAR POWER INC,Mono-c-Si,0,270.0,246.0,1.61,,,60.0,9.1,38.57,8.62,31.4,0.0042406,-0.12427253999999999,46.34,1.5231600464005328,9.102218854137817,9.126501099876554e-11,0.30293845407748937,1242.4162859925948,1.353900572909038,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-275W,DEHUI SOLAR POWER INC,Mono-c-Si,0,275.0,250.7,1.61,,,60.0,9.28,38.58,8.71,31.63,0.00432448,-0.12430475999999999,46.34,1.5367094169092725,9.28937138919521,1.1425871466665056e-10,0.26696993183852963,264.3664708196047,3.0787776846949972,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-280W,DEHUI SOLAR POWER INC,Mono-c-Si,0,280.0,255.4,1.61,,,60.0,9.46,38.7,8.84,31.7,0.004408360000000001,-0.1246914,46.34,1.5442653878818275,9.472995735823512,1.2122986016150787e-10,0.26607068822848884,193.68113057795594,3.427410666502489,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-285W,DEHUI SOLAR POWER INC,Mono-c-Si,0,285.0,260.1,1.61,,,60.0,9.52,38.7,8.86,32.2,0.00443632,-0.1246914,46.34,1.5612816902183513,9.532709704660089,1.5928204655761018e-10,0.19805975043495172,148.35347712609902,5.693635883153043,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-290W,DEHUI SOLAR POWER INC,Mono-c-Si,0,290.0,264.8,1.61,,,60.0,9.58,39.3,9.01,32.2,0.00446428,-0.12662459999999998,46.34,1.5631790680356448,9.588148489468866,1.1412495919507897e-10,0.26623738217162113,313.0094574654978,2.7975041639734344,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-295W,DEHUI SOLAR POWER INC,Mono-c-Si,0,295.0,269.5,1.61,,,60.0,9.61,39.6,9.08,32.5,0.0044782599999999995,-0.1275912,46.34,1.5728228305847693,9.614562172387826,1.1095381128090527e-10,0.2608202708839088,549.4055965377496,2.522005977890695,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-300W,DEHUI SOLAR POWER INC,Mono-c-Si,0,300.0,274.2,1.61,,,60.0,9.7,39.9,9.15,32.8,0.004520199999999999,-0.1285578,46.34,1.5875142836945901,9.70581011550362,1.1678650152142884e-10,0.2533659271611786,422.9949774381595,2.8753334376543616,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-72P-300W,DEHUI SOLAR POWER INC,Multi-c-Si,0,300.0,271.4,1.9227,,,72.0,8.79,45.3,8.22,36.5,0.00462354,-0.1597731,46.8,1.8324975464432063,8.802086103828803,1.589002127382818e-10,0.41086944584390234,298.81778060201634,-3.000893362833508,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-305W,DEHUI SOLAR POWER INC,Mono-c-Si,0,305.0,278.9,1.61,,,60.0,9.77,40.3,9.19,33.2,0.00455282,-0.12984659999999998,46.34,1.6076930449639661,9.777804126556193,1.2528863776748477e-10,0.24476923708355627,306.4270626794063,3.410636788460574,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-72P-305W,DEHUI SOLAR POWER INC,Multi-c-Si,0,305.0,276.1,1.9227,,,72.0,8.96,45.07,8.43,36.19,0.00471296,-0.15896189,46.8,1.8138407265088992,8.966790818343103,1.4367866186303322e-10,0.41856247704251137,552.2633878232857,-3.9539704571452154,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-60M-310W,DEHUI SOLAR POWER INC,Mono-c-Si,0,310.0,283.6,1.61,,,60.0,9.83,40.7,9.26,33.5,0.0045807800000000004,-0.1311354,46.34,1.621620825946704,9.836844352814282,1.2238843620239383e-10,0.24956503652966394,358.4304507478878,3.159113182326572,-0.4074,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-72P-310W,DEHUI SOLAR POWER INC,Multi-c-Si,0,310.0,280.7,1.9227,,,72.0,8.99,45.6,8.49,36.52,0.00472874,-0.1608312,46.8,1.8289158598900683,8.99305956444021,1.3304643731055814e-10,0.4352820158053212,1279.0011796184374,-4.585832708921954,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-72P-315W,DEHUI SOLAR POWER INC,Multi-c-Si,0,315.0,285.4,1.9227,,,72.0,9.03,46.1,8.56,36.8,0.0047497799999999995,-0.1625947,46.8,1.8428889220093465,9.039342857689846,1.2365927379372256e-10,0.45413846275358116,999999.9392241188,-5.197741531690909,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72P-320W,DEHUI SOLAR POWER INC,Multi-c-Si,0,320.0,290.0,1.9227,,,72.0,9.07,46.6,8.63,37.1,0.00477082,-0.1643582,46.8,1.8648124969999842,9.070004054660702,1.2734260928693093e-10,0.4469313690243072,999999.8085035094,-4.999888568329867,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72P-325W,DEHUI SOLAR POWER INC,Multi-c-Si,0,325.0,294.7,1.9227,,,72.0,9.12,47.1,8.69,37.4,0.004797119999999999,-0.1661217,46.8,1.8837787656701537,9.120004142225808,1.2628612492686334e-10,0.45408019628196855,999999.330738776,-5.105665668932621,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72P-330W,DEHUI SOLAR POWER INC,Multi-c-Si,0,330.0,299.4,1.9227,,,72.0,9.18,47.5,8.74,37.8,0.00482868,-0.16753250000000003,46.8,1.9009852885178504,9.180004123219188,1.2915344564243296e-10,0.4490433032577442,999999.699858734,-4.9840820694106505,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-335W,DEHUI SOLAR POWER INC,Mono-c-Si,0,335.0,305.6,1.9227,,,72.0,9.25,46.7,8.89,37.7,0.0043105,-0.15047674,46.34,1.8444200655580587,9.250264373516938,9.328257749849486e-11,0.33710309321875065,11794.70794466476,1.383788047574589,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72P-335W,DEHUI SOLAR POWER INC,Multi-c-Si,0,335.0,304.0,1.9227,,,72.0,9.26,47.8,8.77,38.2,0.00487076,-0.1685906,46.8,1.9120678438424672,9.260004682640254,1.287158122492087e-10,0.45387409325221095,897634.402829163,-5.076436494540273,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +DEHUI SOLAR POWER INC DH-72M-340W,DEHUI SOLAR POWER INC,Mono-c-Si,0,340.0,310.3,1.9227,,,72.0,9.29,47.3,8.91,38.2,0.00432914,-0.15241005999999999,46.34,1.8666933517624342,9.290276236372964,9.18937665285861e-11,0.3499289407359628,11768.344773868072,1.2262580191992398,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72P-340W,DEHUI SOLAR POWER INC,Multi-c-Si,0,340.0,308.7,1.9227,,,72.0,9.31,48.1,8.84,38.5,0.00489706,-0.1696487,46.8,1.9278007711296614,9.310004048537586,1.3582868558175108e-10,0.4347538067475835,999999.9107767029,-4.7055682349440575,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-345W,DEHUI SOLAR POWER INC,Mono-c-Si,0,345.0,315.0,1.9227,,,72.0,9.31,47.8,9.03,38.22,0.004338460000000001,-0.15402116,46.34,1.8875030138976503,9.310215140626779,9.343883187207327e-11,0.32651712684031775,14129.733500419055,1.3444975010009288,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-350W,DEHUI SOLAR POWER INC,Mono-c-Si,0,350.0,319.7,1.9227,,,72.0,9.34,48.3,9.1,38.5,0.00435244,-0.15563226,46.34,1.9085602311120864,9.340201399391296,9.538779133240843e-11,0.30670345634618057,14223.398085493882,1.4867957622351882,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-355W,DEHUI SOLAR POWER INC,Mono-c-Si,0,355.0,324.4,1.9227,,,72.0,9.4,48.7,9.15,38.8,0.0043804000000000004,-0.15692114000000001,46.34,1.9231023926404467,9.400209955253503,9.441726306544879e-11,0.3174300333934768,14211.761176647618,1.3510050352655585,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-360W,DEHUI SOLAR POWER INC,Mono-c-Si,0,360.0,329.1,1.9227,,,72.0,9.45,49.1,9.21,39.1,0.0044037,-0.15821002,46.34,1.9400502582984083,9.450371239098663,9.633088619616083e-11,0.30775912961717,7834.023192765652,1.4724260839684271,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-365W,DEHUI SOLAR POWER INC,Mono-c-Si,0,365.0,333.8,1.9227,,,72.0,9.52,49.4,9.27,39.4,0.00443632,-0.15917668000000001,46.34,1.9520218650833077,9.52020736623359,9.72203031289731e-11,0.3100567998021152,14234.333095236623,1.4863103353332325,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-370W,DEHUI SOLAR POWER INC,Mono-c-Si,0,370.0,338.5,1.9227,,,72.0,9.6,49.7,9.34,39.7,0.0044736,-0.16014334000000002,46.34,1.964473705092137,9.600208894833948,9.879479573004661e-11,0.309426416202938,14220.01338941155,1.5492178284731688,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DEHUI SOLAR POWER INC DH-72M-375W,DEHUI SOLAR POWER INC,Mono-c-Si,0,375.0,343.3,1.9227,,,72.0,9.65,50.1,9.38,40.0,0.004496900000000001,-0.16143222000000002,46.34,1.978987186311081,9.650217339145529,9.767603364858676e-11,0.3201015489635939,14212.723985187313,1.4137259351583056,-0.407,N,2025.7.3,6/23/2025,2.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW380M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,380.0,358.5,1.9,,,54.0,13.2,36.31,12.45,30.51,0.006600000000000001,-0.09404290000000001,42.3,1.3452268123394053,13.20994511870549,2.4630442478328524e-11,0.128266784400968,170.24649455938044,10.23444212843627,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW385M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,385.0,363.3,1.9,,,54.0,13.35,36.37,12.6,30.56,0.006675,-0.0941983,42.3,1.346998765001473,13.359553766005535,2.470590916571264e-11,0.12713179100809172,177.6482091124499,10.157724895069332,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW390M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,390.0,368.2,1.9,,,54.0,13.5,36.45,12.73,30.63,0.006750000000000001,-0.09440550000000002,42.3,1.350618011352497,13.510332934542328,2.5286270951366666e-11,0.12566694009664645,164.1841138997132,10.269555727765265,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW395M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,395.0,373.0,1.9,,,54.0,13.52,36.63,12.75,30.98,0.0067599999999999995,-0.0948717,42.3,1.3616273800191978,13.529090971397643,2.7584852381033424e-11,0.10823353642957365,160.96381310650213,11.039371044636663,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW400M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,400.0,377.8,1.9,,,54.0,13.53,37.32,12.76,31.36,0.006765,-0.09665880000000002,42.3,1.382740922328944,13.540260538560487,2.529017368924222e-11,0.12849067902265052,169.43349389222368,10.250463250010093,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW405M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,405.0,382.7,1.9,,,54.0,13.68,37.34,12.91,31.38,0.006840000000000001,-0.09671060000000002,42.3,1.34932661775517,13.691095579415363,1.2908759804847389e-11,0.13279586843012722,163.7271401634268,4.290552043926586,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW410M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,410.0,387.5,1.9,,,54.0,13.79,37.51,13.01,31.52,0.006895,-0.0971509,42.3,1.353542448712091,13.80151704333593,1.2504755161205088e-11,0.13292245414260814,159.15548764388706,3.953997322676249,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW415M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,415.0,392.3,1.9,,,54.0,13.92,37.62,13.13,31.61,0.00696,-0.0974358,42.3,1.3936968589209018,13.930437758037872,2.594424757849417e-11,0.12609176965578817,168.1584721787754,10.223898364599286,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW420M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,420.0,397.2,1.9,,,54.0,14.07,37.66,13.27,31.65,0.007035000000000001,-0.0975394,42.3,1.3953961811181876,14.080601954461624,2.6330400438594483e-11,0.12431810286781451,164.98427032676048,10.26076243550283,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW430M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,430.0,406.9,1.9,,,60.0,13.56,39.68,12.79,33.6,0.0067800000000000004,-0.1027712,42.3,1.475767958402918,13.568771854929778,2.8057553693615915e-11,0.11329601584653733,175.1390084819516,11.165505480905926,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW435M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,435.0,411.7,1.9,,,60.0,13.7,39.7,12.93,33.65,0.006849999999999999,-0.10282300000000001,42.3,1.4767959809704263,13.708293050473664,2.851233886396855e-11,0.1093381161259628,180.6249949582362,11.215458871120335,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW440M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,440.0,416.6,1.9,,,60.0,13.73,39.79,13.05,33.72,0.0068650000000000004,-0.1030561,42.3,1.4749420516218776,13.733952212784471,2.6206343383911823e-11,0.11073617272875927,384.6978783912625,10.405609905209397,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW445M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,445.0,421.4,1.9,,,60.0,13.81,40.26,13.15,33.83,0.0069050000000000005,-0.1042734,42.3,1.4847887696804558,13.81295342671283,2.30367230271697e-11,0.1366992351231213,639.1953012284865,9.19357869080543,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW450M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,450.0,426.3,1.9,,,60.0,13.82,41.72,13.16,34.2,0.006910000000000001,-0.1080548,42.3,1.5198328171403517,13.822029266870853,1.6524523525590472e-11,0.21625503207621663,1472.7706710746402,6.268070948002315,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW455M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,455.0,431.2,1.9,,,60.0,14.06,41.73,13.26,34.3,0.007030000000000001,-0.1080807,42.3,1.5290579824976271,14.07394954413182,1.9483190938212972e-11,0.20461269667732226,206.23287152088446,7.593871969410087,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW460M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,460.0,436.0,1.9,,,60.0,14.13,41.75,13.33,34.5,0.007065000000000001,-0.10813249999999999,42.3,1.5336827010681804,14.143026577084427,2.0980467107751037e-11,0.18786051484035976,203.77333786506517,8.200568348523623,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW480M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,480.0,455.5,1.9,,,66.0,13.72,44.14,12.94,37.09,0.0068600000000000015,-0.11432260000000001,42.3,1.6353596208294288,13.730360429818173,2.561821138700238e-11,0.14994856336671922,198.57230488428652,10.240710333491267,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW485M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,485.0,460.4,1.9,,,66.0,13.85,44.16,13.07,37.11,0.006925000000000001,-0.1143744,42.3,1.5855194209882773,13.861603569672608,1.0923622398422757e-11,0.15701518260453767,187.41304154261056,2.776538132208929,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,490.0,465.3,1.9,,,66.0,13.98,44.21,13.19,37.15,0.0069900000000000006,-0.1145039,42.3,1.637691406424725,13.990267278880157,2.6002350136356104e-11,0.14732718513315252,200.6017456146856,10.204313089226458,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW495M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,495.0,470.2,1.9,,,66.0,14.08,44.38,13.28,37.29,0.007040000000000001,-0.11494420000000001,42.3,1.6441865797000477,14.090612648911735,2.6263611246032364e-11,0.147056692631238,195.10286851307598,10.231411706572457,-0.339,N,2025.7.3,6/23/2025,4.0,bootstrapping +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW500M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,500.0,475.0,1.9,,,66.0,14.09,44.36,13.3,37.6,0.007045,-0.1148924,42.3,1.650029429343874,14.098437565363927,2.927483606987847e-11,0.11879681567167771,198.38034681681728,11.199672515182662,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW505M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,505.0,479.9,1.9,,,66.0,14.11,45.16,13.31,37.95,0.0070550000000000005,-0.11696440000000001,42.3,1.6730822064124855,14.12051220733352,2.632249051078644e-11,0.14893886176755058,199.91304231179066,10.231881761193112,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW510M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,510.0,484.8,1.9,,,66.0,14.18,45.37,13.38,38.13,0.007090000000000001,-0.1175083,42.3,1.680698695795358,14.190312909589126,2.639264755219531e-11,0.14862075415517725,204.34992388034573,10.210136086787234,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW520M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,520.0,494.6,1.9,,,72.0,13.57,48.33,12.8,40.61,0.006785000000000001,-0.1251747,42.3,1.790479496054832,13.580163029168569,2.529693231095228e-11,0.1660800536222701,221.75537421738431,10.22563511819662,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW525M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,525.0,499.5,1.9,,,72.0,13.68,48.41,12.91,40.68,0.006840000000000001,-0.1253819,42.3,1.793084510239752,13.689863168490675,2.5378891711104328e-11,0.16482498017051886,228.60872044542603,10.180226622065303,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW530M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,530.0,504.4,1.9,,,72.0,13.75,48.64,12.97,40.87,0.006875000000000001,-0.1259776,42.3,1.8019389733134439,13.760287201216597,2.562338085018584e-11,0.16500175226964744,220.54337813166057,10.222379438880445,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW535M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,535.0,509.3,1.9,,,72.0,13.84,48.77,13.06,40.98,0.00692,-0.12631430000000002,42.3,1.8064296605391272,13.850047884779237,2.5677760325476056e-11,0.16434347186445847,226.36741197862833,10.181253551506185,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW540M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,540.0,514.2,1.9,,,72.0,13.92,48.94,13.09,41.13,0.00696,-0.1267546,42.3,1.8159470724821631,13.932762497227102,2.698219858495874e-11,0.16294556786823405,177.7240205981184,10.58899941621151,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW545M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,545.0,519.1,1.9,,,72.0,14.0,49.5,13.1,41.6,0.007000000000000001,-0.128205,42.3,1.8411989370815893,14.016668478872624,2.8804486647054976e-11,0.16332466454740335,137.17780321652137,11.147254219599274,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW550M,DONGGUAN SUNWORTH SOLAR ENERGY CO LTD,Mono-c-Si,0,550.0,524.1,1.9,,,72.0,14.01,49.9,13.11,41.96,0.007005000000000001,-0.129241,42.3,1.8565682903250165,14.026455899483532,2.90308747890466e-11,0.16244413873514899,138.29948317068906,11.211419668613045,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA095-A2,Du Pont Apollo,Thin Film,0,95.0,86.3,1.54,1.4,1.1,119.0,1.62,100.0,1.3,73.0,0.0013105800000000002,-0.3283,46.7,3.9580266142481983,1.6888502997846275,1.4228988226481258e-11,12.03096107994999,283.0802125860977,-1.7534566731928136,-0.3514,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA100-A2,Du Pont Apollo,Thin Film,0,100.0,90.9,1.54,1.4,1.1,119.0,1.66,100.0,1.34,75.0,0.00134294,-0.3283,46.7,4.02025900696868,1.7162378046740048,2.1628138724574604e-11,9.869992825532822,291.33762510878483,1.4654922974036073,-0.3514,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA100-A6,Du Pont Apollo,Thin Film,0,100.0,94.2,1.54,1.4,1.1,119.0,1.66,100.0,1.34,75.0,0.0012940031999999998,-0.316147,46.1,3.4841916169188885,1.7235118857700735,4.687379021863299e-13,10.719927797676776,280.1850385947924,-22.83404986856895,-0.22912,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA102-A6,Du Pont Apollo,Thin Film,0,102.0,96.1,1.54,1.4,1.1,119.0,1.66,100.0,1.4,75.0,0.0012940031999999998,-0.316147,46.1,3.396534210514623,1.7059003036023597,2.359611755090127e-13,10.51429099152042,380.2528891326153,-27.1844719099555,-0.22912,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA105-A2,Du Pont Apollo,Thin Film,0,105.0,95.5,1.54,1.4,1.1,119.0,1.66,100.0,1.4,75.0,0.00134294,-0.3283,46.7,3.9113696579573047,1.7002835207528175,1.1437791583684539e-11,9.74274335354472,401.47817139520305,-3.696241186699863,-0.3514,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA105-A6,Du Pont Apollo,Thin Film,0,105.0,98.9,1.54,1.4,1.1,119.0,1.66,100.0,1.4,75.0,0.0012940031999999998,-0.316147,46.1,3.396534210514623,1.7059003036023597,2.359611755090127e-13,10.51429099152042,380.2528891326153,-27.1844719099555,-0.22912,N,2025.7.3,6/23/2025,4.0,first_pass +Du Pont Apollo DA130-C2,Du Pont Apollo,Thin Film,0,130.0,119.6,1.54,1.4,1.1,119.0,1.28,154.96,1.08,120.75,-0.0007040000000000001,-0.480376,46.8,5.159187448560116,1.3076569399728222,9.990000001031523e-14,16.63830167995682,770.0427515170798,-27.215360147394573,-0.316,N,2025.7.3,6/23/2025,2.0,first_pass +Du Pont Apollo DA133-C2,Du Pont Apollo,Thin Film,0,133.0,122.4,1.54,1.4,1.1,119.0,1.29,156.73,1.09,122.13,-0.0007095,-0.485863,46.8,5.216459991489417,1.317533674739594,9.990000001020319e-14,16.684130052374034,781.6801780383441,-27.267832022234195,-0.316,N,2025.7.3,6/23/2025,2.0,first_pass +Du Pont Apollo DA136-C2,Du Pont Apollo,Thin Film,0,136.0,125.2,1.54,1.4,1.1,119.0,1.31,158.49,1.1,123.5,-0.0007205,-0.49131900000000006,46.8,5.273695017085596,1.3395060657699878,9.99000000102118e-14,16.689390291193746,740.9697198082636,-27.332136091781816,-0.316,N,2025.7.3,6/23/2025,2.0,first_pass +DualSun SAS DualSun 280M-60-00,DualSun SAS,Mono-c-Si,0,280.0,254.2,1.64,,,60.0,9.34,39.3,8.75,32.0,0.0033623999999999998,-0.11161199999999998,48.2,1.5094848832339967,9.353341868712194,4.5238974010687754e-11,0.31200706079816687,218.42112111469075,8.709190757148424,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 285M-60-00,DualSun SAS,Mono-c-Si,0,285.0,258.9,1.64,,,60.0,9.46,39.5,8.88,32.1,0.0034056000000000004,-0.11218,48.2,1.51411076926535,9.4719450115273,4.358585182331125e-11,0.31788932636021794,251.75639970287617,8.263281227516543,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 290M-60-00,DualSun SAS,Mono-c-Si,0,290.0,263.6,1.64,,,60.0,9.58,39.7,8.98,32.3,0.0034487999999999997,-0.112748,48.2,1.5237707696482095,9.593261337103533,4.558963146729344e-11,0.3106274923796895,224.39754119608742,8.552043034785317,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 295M-60-00,DualSun SAS,Mono-c-Si,0,295.0,268.2,1.64,,,60.0,9.69,39.9,9.05,32.6,0.0034883999999999996,-0.113316,48.2,1.5376891877900896,9.706034671264815,5.10130943963153e-11,0.2909249947932414,175.81047934626267,9.45549503916275,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 300M-60-00,DualSun SAS,Mono-c-Si,0,300.0,272.9,1.64,,,60.0,9.81,40.1,9.15,32.8,0.0035315999999999998,-0.113884,48.2,1.5473471012411215,9.82715261716305,5.327209344316843e-11,0.2840947467854717,162.48071029275835,9.735227111874273,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 305M-60-00,DualSun SAS,Mono-c-Si,0,305.0,278.6,1.64,,,60.0,9.94,40.2,9.24,33.0,0.0041748,-0.11215800000000002,48.75,1.525135194196247,9.96064124002585,3.447441470510852e-11,0.2734669653900962,131.69081193842513,7.6921850882543605,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 310M-60-00,DualSun SAS,Mono-c-Si,0,310.0,283.3,1.64,,,60.0,9.98,40.3,9.35,33.2,0.0041916,-0.112437,48.75,1.5258301402749765,9.993650490012584,3.3101612301726905e-11,0.2588704333715345,189.26257961877317,7.273705423219434,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 315M-60-00,DualSun SAS,Mono-c-Si,0,315.0,288.0,1.64,,,60.0,10.1,40.5,9.43,33.4,0.004242,-0.11299500000000001,48.75,1.5368819693650824,10.116316653094328,3.5416125682032715e-11,0.25250616410675447,156.30118911609287,7.771420314125466,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 320M-60-00,DualSun SAS,Mono-c-Si,0,320.0,292.7,1.64,,,60.0,10.19,40.8,9.52,33.6,0.0042798,-0.113832,48.75,1.5466311455624888,10.206261394861377,3.4780732708949016e-11,0.25794185079463894,161.63604088939266,7.533794442309842,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 335M-120-00,DualSun SAS,Mono-c-Si,0,335.0,312.0,1.81,,,60.0,10.76,39.9,10.25,32.7,0.0047344,-0.10733100000000001,45.55,1.4419822320023414,10.760006319308731,1.0346055121128202e-11,0.2688783138136464,457828.7382283072,0.5652576577168564,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 340M-120-00,DualSun SAS,Mono-c-Si,0,340.0,316.8,1.81,,,60.0,10.84,40.1,10.34,32.9,0.0047696,-0.107869,45.55,1.4509663536684432,10.840250761720673,1.0774788488405712e-11,0.2638624495321133,11406.323870845472,0.8385083963459691,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 345M-120-00,DualSun SAS,Mono-c-Si,0,345.0,321.5,1.81,,,60.0,10.93,40.3,10.43,33.1,0.0048092,-0.108407,45.55,1.4587873052409468,10.930002829593215,1.0988431242349266e-11,0.2588732676196107,999992.1601255443,0.9307810245976665,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +DualSun SAS DualSun 350M-120-00,DualSun SAS,Mono-c-Si,0,350.0,326.3,1.81,,,60.0,11.02,40.5,10.52,33.3,0.0048487999999999995,-0.10894500000000001,45.55,1.4669223020722264,11.02000424318334,1.126728626581356e-11,0.2542199596246696,660246.3445036906,1.069397934122982,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 350M-120-01,DualSun SAS,Mono-c-Si,0,350.0,326.0,1.81,,,60.0,11.02,40.5,10.52,33.3,0.0048487999999999995,-0.10854000000000001,45.71,1.4701187263319382,11.020004230842114,1.1964361339960272e-11,0.2535548224432999,660440.2831863697,1.9455738278563786,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 355M-120-00,DualSun SAS,Mono-c-Si,0,355.0,331.1,1.81,,,60.0,11.1,40.7,10.6,33.5,0.0048839999999999995,-0.10948300000000001,45.55,1.4750308243372956,11.100004252101789,1.153420848785123e-11,0.24972717031452096,651915.9637969732,1.2025824184161844,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 355M-120-01,DualSun SAS,Mono-c-Si,0,355.0,330.8,1.81,,,60.0,11.1,40.7,10.6,33.5,0.0048839999999999995,-0.10907600000000002,45.71,1.478245549290702,11.100004239482372,1.2247510622702869e-11,0.24906284630450598,652117.686789903,2.079652273530307,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 360M-120-00,DualSun SAS,Mono-c-Si,0,360.0,335.9,1.81,,,60.0,11.2,40.9,10.69,33.7,0.004927999999999999,-0.110021,45.55,1.48263584825762,11.20000526984601,1.1715623597873685e-11,0.24505185313133254,520813.84616128117,1.2572659112758222,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 360M-120-01,DualSun SAS,Mono-c-Si,0,360.0,335.5,1.81,,,60.0,11.2,40.9,10.69,33.7,0.004927999999999999,-0.109612,45.71,1.4858654619844704,11.200002734254834,1.2439615737117543e-11,0.24412394589428807,999999.8838411157,2.1344178201489656,-0.339,N,2025.7.3,6/23/2025,2.0,first_pass +DualSun SAS DualSun 365M-120-00,DualSun SAS,Mono-c-Si,0,365.0,340.7,1.81,,,60.0,11.28,41.1,10.77,33.9,0.004963199999999999,-0.11055900000000002,45.55,1.4907421057462251,11.280004295743383,1.1987757101385377e-11,0.24069938476348046,632050.8450026102,1.3879013514582108,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 365M-120-01,DualSun SAS,Mono-c-Si,0,365.0,340.3,1.81,,,60.0,11.28,41.1,10.77,33.9,0.004963199999999999,-0.11014800000000001,45.71,1.4939906239063119,11.280004282435096,1.2728380289464018e-11,0.24003747313011126,632272.0261345349,2.266010474336072,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 370M-120-01,DualSun SAS,Mono-c-Si,0,370.0,345.1,1.81,,,60.0,11.37,41.3,10.86,34.1,0.005002799999999999,-0.110684,45.71,1.5021405175495846,11.37000428722497,1.3038350502896535e-11,0.2355340905828599,624661.1381155598,2.40010767918571,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 375M-120-01,DualSun SAS,Mono-c-Si,0,375.0,352.0,1.77,,,60.0,11.6,41.1,10.84,34.6,0.004292,-0.10891500000000001,44.02,1.5159858478255575,11.614666503104422,1.8990092776035743e-11,0.16033483684857758,126.8116946483748,6.802025934557694,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 380M-120-01,DualSun SAS,Mono-c-Si,0,380.0,356.9,1.77,,,60.0,11.69,41.3,10.92,34.8,0.0043253,-0.109445,44.02,1.524354968185041,11.704731155101351,1.946785398044799e-11,0.1565020771926589,124.19319942449192,6.952236829990765,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 420M-144-01,DualSun SAS,Mono-c-Si,0,420.0,394.1,2.16,,,72.0,11.04,48.8,10.45,40.2,0.0054096000000000005,-0.130784,43.92,1.7786071771007477,11.047624868469594,1.3272650319138247e-11,0.29681949797994683,429.763123253536,2.761325302947472,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DSTN425M12-B320SBB7,DualSun SAS,Mono-c-Si,0,425.0,372.6,2.02,,,32.0,12.56,43.4,11.81,36.0,0.005024000000000001,-0.12369,57.8,1.694410100430336,12.570924198913115,9.30125445778189e-11,0.18871790176234224,216.97672543192982,12.030072364724857,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 425M-144-01,DualSun SAS,Mono-c-Si,0,425.0,398.9,2.16,,,72.0,11.11,49.0,10.52,40.4,0.0054439,-0.13132,43.92,1.786382772217455,11.117308518000097,1.3461374871128027e-11,0.29231793494876396,444.36536769348436,2.825400643592275,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 430M-144-01,DualSun SAS,Mono-c-Si,0,430.0,403.7,2.16,,,72.0,11.19,49.2,10.6,40.6,0.0054831,-0.13185600000000003,43.92,1.782476335404528,11.190016818108152,1.1518689197380298e-11,0.28982123162715806,192493.8147201434,1.4366975124025247,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 435M-144-01,DualSun SAS,Mono-c-Si,0,435.0,408.5,2.16,,,72.0,11.26,49.4,10.67,40.8,0.0055174,-0.132392,43.92,1.8018933517242837,11.266658661116818,1.3846957619494357e-11,0.2832433135450498,478.97312796860524,2.9470749936317726,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +DualSun SAS DualSun 440M-144-01,DualSun SAS,Mono-c-Si,0,440.0,413.3,2.16,,,72.0,11.33,49.6,10.74,41.0,0.0055517,-0.13292800000000002,43.92,1.7987453725427527,11.330011076563874,1.198535324326486e-11,0.28096588017282065,287396.0039562075,1.6623620945892077,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST265M-60,DuCal Solar Technology LLC,Mono-c-Si,0,265.0,238.1,1.6268,,,60.0,9.05,38.26,8.52,31.11,0.0057377,-0.13547866,46.6,1.6240732223684784,9.054170904651166,5.280668763343149e-10,0.28028422998856134,608.1586313110308,6.036979169559025,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST270M-60,DuCal Solar Technology LLC,Mono-c-Si,0,270.0,242.7,1.6268,,,60.0,9.17,38.46,8.62,31.33,0.00581378,-0.13618686000000002,46.6,1.6356449365472208,9.175351926258957,5.582354015640016e-10,0.2700462956702555,462.69796469339036,6.40745106967331,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST275M-60,DuCal Solar Technology LLC,Mono-c-Si,0,275.0,247.4,1.6268,,,60.0,9.25,38.86,8.73,31.51,0.0058645,-0.13760326,46.6,1.6446646604507658,9.252210512433903,5.049742361245628e-10,0.2906539046126313,1216.2569589378252,5.45743591817908,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST280M-60,DuCal Solar Technology LLC,Mono-c-Si,0,280.0,252.0,1.6268,,,60.0,9.37,39.05,8.84,31.68,0.005940579999999999,-0.13827604999999998,46.6,1.6535159446788723,9.372563454914495,5.17222716102302e-10,0.28617507967076516,1046.0346644090296,5.553483614513898,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST285M-60,DuCal Solar Technology LLC,Mono-c-Si,0,285.0,256.7,1.6268,,,60.0,9.49,39.25,8.95,31.85,0.00601666,-0.13898425,46.6,1.6625393759609615,9.492902408753316,5.277501681602507e-10,0.28295165323405774,925.1671006045988,5.61826229262858,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST290M-60,DuCal Solar Technology LLC,Mono-c-Si,0,290.0,261.3,1.6268,,,60.0,9.56,39.46,9.06,32.07,0.00606104,-0.13972786,46.6,1.6695760636416723,9.571569943015346,5.206468299809413e-10,0.2758931455984716,999999.980550971,5.41819830615019,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +DuCal Solar Technology LLC DST295M-60,DuCal Solar Technology LLC,Mono-c-Si,0,295.0,266.0,1.6268,,,60.0,9.72,39.64,9.14,32.29,0.0061624800000000006,-0.14036524000000003,46.6,1.6854920325423866,9.725415548141417,5.891784953520707e-10,0.26277773378783686,471.6421109860132,6.369257400821876,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST300M-60,DuCal Solar Technology LLC,Mono-c-Si,0,300.0,270.6,1.6268,,,60.0,9.84,39.82,9.23,32.51,0.00623856,-0.14100262000000002,46.6,1.6976732378803763,9.847334339655337,6.330267661241469e-10,0.25108960745190123,336.8704688223921,6.89268259678697,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +DuCal Solar Technology LLC DST305M-60,DuCal Solar Technology LLC,Mono-c-Si,0,305.0,275.3,1.6268,,,60.0,9.96,40.0,9.32,32.73,0.006314640000000001,-0.14164000000000002,46.6,1.7098595886651011,9.969081811396846,6.795222374782117e-10,0.23962518580135975,262.7964058119921,7.41204264140735,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-390,Elin Energy (Sirius PV),Mono-c-Si,0,390.0,367.3,1.94,,,54.0,13.4,36.92,12.79,30.57,0.006083600000000001,-0.08650356000000001,43.2,1.3264575180136045,13.400914994532188,1.0932384070031039e-11,0.17411637667178012,2549.9163590191492,14.010111776820928,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-390,Elin Energy (Sirius PV),Mono-c-Si,0,390.0,367.3,1.94,,,54.0,13.4,36.92,12.79,30.57,0.006083600000000001,-0.08650356000000001,43.2,1.3264575180136045,13.400914994532188,1.0932384070031039e-11,0.17411637667178012,2549.9163590191492,14.010111776820928,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-395,Elin Energy (Sirius PV),Mono-c-Si,0,395.0,372.1,1.94,,,54.0,13.5,37.02,12.89,30.69,0.006129000000000001,-0.08673786000000001,43.2,1.330608676924525,13.500640387351282,1.1146650711019676e-11,0.1700023900229187,3583.8191439625357,14.120340186748034,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-395,Elin Energy (Sirius PV),Mono-c-Si,1,395.0,372.6,1.94,,,54.0,13.5,37.02,12.89,30.69,0.0057105,-0.08951436,43.2,1.3176158317421542,13.501067408283781,8.4682918130372e-12,0.17224491733300623,2178.4602092839036,8.146292295425795,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-395,Elin Energy (Sirius PV),Mono-c-Si,0,395.0,372.1,1.94,,,54.0,13.5,37.02,12.89,30.69,0.006129000000000001,-0.08673786000000001,43.2,1.330608676924525,13.500640387351282,1.1146650711019676e-11,0.1700023900229187,3583.8191439625357,14.120340186748034,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-400,Elin Energy (Sirius PV),Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.6,37.12,12.99,30.81,0.006174400000000001,-0.08697215999999999,43.2,1.3350100009124026,13.600606123711957,1.142000807245267e-11,0.16591336053047953,3722.708494372136,14.27721419528387,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-400,Elin Energy (Sirius PV),Mono-c-Si,1,400.0,377.5,1.94,,,54.0,13.6,37.12,12.99,30.81,0.0057528,-0.08975615999999999,43.2,1.321728964695107,13.600794428375783,8.634574373476766e-12,0.168185696795954,2879.209365648115,8.251841020063912,-0.3247,N,2025.7.3,6/23/2025,4.0,bootstrapping +Elin Energy (Sirius PV) ELNSM54M-HC-LV-400,Elin Energy (Sirius PV),Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.6,37.12,12.99,30.81,0.006174400000000001,-0.08697215999999999,43.2,1.3350100009124026,13.600606123711957,1.142000807245267e-11,0.16591336053047953,3722.708494372136,14.27721419528387,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-405,Elin Energy (Sirius PV),Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.7,37.22,13.1,30.93,0.006219799999999999,-0.08720646,43.2,1.3388045045225017,13.708800776836215,1.1566744458304908e-11,0.1618693983005694,999999.9728196929,14.319450982928567,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-405,Elin Energy (Sirius PV),Mono-c-Si,1,405.0,382.3,1.94,,,54.0,13.7,37.22,13.1,30.93,0.005795099999999999,-0.08999795999999999,43.2,1.3263214855471321,13.700609153269294,8.891955506905565e-12,0.1640644666037802,3689.848589664629,8.446290316346147,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-405,Elin Energy (Sirius PV),Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.7,37.22,13.1,30.93,0.006219799999999999,-0.08720646,43.2,1.3388045045225017,13.708800776836215,1.1566744458304908e-11,0.1618693983005694,999999.9728196929,14.319450982928567,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-410,Elin Energy (Sirius PV),Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.8,37.32,13.21,31.05,0.006265200000000001,-0.08744076,43.2,1.2965982649767718,13.800002288401007,4.360897160963759e-12,0.16581319785656473,999931.0569461143,5.473679253240096,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-410,Elin Energy (Sirius PV),Mono-c-Si,1,410.0,387.1,1.94,,,54.0,13.8,37.32,13.21,31.05,0.0058374,-0.09023976,43.2,1.8652941094098618,13.800843837658224,4.042803633287685e-13,2.332229771553827,38718.90529049275,78.65199034753664,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-410,Elin Energy (Sirius PV),Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.8,37.32,13.21,31.05,0.006265200000000001,-0.08744076,43.2,1.2965982649767718,13.800002288401007,4.360897160963759e-12,0.16581319785656473,999931.0569461143,5.473679253240096,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-415,Elin Energy (Sirius PV),Mono-c-Si,0,415.0,391.4,1.94,,,54.0,13.9,37.42,13.32,31.16,0.006310600000000001,-0.08767506000000001,43.2,1.2996389800760306,13.900004185672326,4.350513861313786e-12,0.16286611317872954,540856.9700581725,5.390186511743396,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-415,Elin Energy (Sirius PV),Mono-c-Si,1,415.0,391.9,1.94,,,54.0,13.9,37.42,13.32,31.16,0.0058797,-0.09048156,43.2,1.3356980885726282,13.900599265348019,9.458367011262946e-12,0.15682126661753545,3637.480049084325,8.865902347371788,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-415,Elin Energy (Sirius PV),Mono-c-Si,0,415.0,391.4,1.94,,,54.0,13.9,37.42,13.32,31.16,0.006310600000000001,-0.08767506000000001,43.2,1.2996389800760306,13.900004185672326,4.350513861313786e-12,0.16286611317872954,540856.9700581725,5.390186511743396,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-415,Elin Energy (Sirius PV),Mono-c-Si,0,415.0,393.8,1.94,,,54.0,13.75,38.3,13.1,31.7,0.006242500000000001,-0.0881666,43.2,1.3228141945386553,13.75488965008778,3.646118684753514e-12,0.18632563934504937,523.9592819952071,5.842310265341034,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-415,Elin Energy (Sirius PV),Mono-c-Si,0,415.0,393.8,1.94,,,54.0,13.75,38.3,13.1,31.7,0.006242500000000001,-0.0881666,43.2,1.3228141945386553,13.75488965008778,3.646118684753514e-12,0.18632563934504937,523.9592819952071,5.842310265341034,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-420,Elin Energy (Sirius PV),Mono-c-Si,0,420.0,396.3,1.94,,,54.0,14.0,37.52,13.42,31.28,0.006356000000000001,-0.08790936,43.2,1.3531649236190846,14.000101678948942,1.2709735172338497e-11,0.15079068596601564,20762.120918766537,15.00427021139318,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-420,Elin Energy (Sirius PV),Mono-c-Si,1,420.0,396.8,1.94,,,54.0,14.0,37.52,13.42,31.28,0.005922,-0.09072336,43.2,1.3400905773986045,14.000604727872286,9.691576724951872e-12,0.15296465536768666,3541.2710553320417,9.018935201822941,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-420,Elin Energy (Sirius PV),Mono-c-Si,0,420.0,396.3,1.94,,,54.0,14.0,37.52,13.42,31.28,0.006356000000000001,-0.08790936,43.2,1.3531649236190846,14.000101678948942,1.2709735172338497e-11,0.15079068596601564,20762.120918766537,15.00427021139318,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420,Elin Energy (Sirius PV),Mono-c-Si,0,420.0,398.7,1.94,,,54.0,13.83,38.5,13.17,31.9,0.006278820000000001,-0.088627,43.2,1.3306628227157917,13.835465718124594,3.740754135556926e-12,0.18323692910776662,463.64753568547576,6.018495804325587,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-420,Elin Energy (Sirius PV),Mono-c-Si,0,420.0,398.7,1.94,,,54.0,13.83,38.5,13.17,31.9,0.006278820000000001,-0.088627,43.2,1.3306628227157917,13.835465718124594,3.740754135556926e-12,0.18323692910776662,463.64753568547576,6.018495804325587,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-425,Elin Energy (Sirius PV),Mono-c-Si,0,425.0,401.1,1.94,,,54.0,14.1,37.62,13.52,31.4,0.0064014,-0.08814366,43.2,1.303932032812014,14.100004100753097,4.161993599980916e-12,0.15587723065802372,535969.5414455662,4.882033074764861,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-425,Elin Energy (Sirius PV),Mono-c-Si,1,425.0,401.6,1.94,,,54.0,14.1,37.62,13.52,31.4,0.005964299999999999,-0.09096515999999999,43.2,1.3437751823440138,14.100002104774928,9.790758934455321e-12,0.1492715513047107,999996.5455203147,9.043304224675461,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-425,Elin Energy (Sirius PV),Mono-c-Si,0,425.0,401.1,1.94,,,54.0,14.1,37.62,13.52,31.4,0.0064014,-0.08814366,43.2,1.303932032812014,14.100004100753097,4.161993599980916e-12,0.15587723065802372,535969.5414455662,4.882033074764861,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-425,Elin Energy (Sirius PV),Mono-c-Si,0,425.0,403.5,1.94,,,54.0,13.91,38.7,13.24,32.1,0.00631514,-0.0890874,43.2,1.3385124109782713,13.916019600714376,3.836904564340079e-12,0.18018081900368327,416.3590445393433,6.193040516222982,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-425,Elin Energy (Sirius PV),Mono-c-Si,0,425.0,403.5,1.94,,,54.0,13.91,38.7,13.24,32.1,0.00631514,-0.0890874,43.2,1.3385124109782713,13.916019600714376,3.836904564340079e-12,0.18018081900368327,416.3590445393433,6.193040516222982,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-430,Elin Energy (Sirius PV),Mono-c-Si,0,430.0,405.9,1.94,,,54.0,14.2,37.72,13.62,31.52,0.0064468,-0.08837795999999999,43.2,1.3062007619890077,14.200004055616136,4.082113408524231e-12,0.15244084708856265,533746.0953600897,4.653324806980824,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-430,Elin Energy (Sirius PV),Mono-c-Si,1,430.0,406.5,1.94,,,54.0,14.2,37.72,13.62,31.52,0.006006599999999999,-0.09120695999999999,43.2,1.3239354944997546,14.20000397723137,6.010117657147586e-12,0.14950918434608815,533799.2583920878,4.711306712898249,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-430,Elin Energy (Sirius PV),Mono-c-Si,0,430.0,405.9,1.94,,,54.0,14.2,37.72,13.62,31.52,0.0064468,-0.08837795999999999,43.2,1.3062007619890077,14.200004055616136,4.082113408524231e-12,0.15244084708856265,533746.0953600897,4.653324806980824,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-430,Elin Energy (Sirius PV),Mono-c-Si,0,430.0,408.4,1.94,,,54.0,13.99,38.9,13.32,32.3,0.006351460000000001,-0.0895478,43.2,1.3459204621012224,13.995724409196717,3.900791037953958e-12,0.1771658642008649,432.9792586669269,6.286673488033272,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-430,Elin Energy (Sirius PV),Mono-c-Si,0,430.0,408.4,1.94,,,54.0,13.99,38.9,13.32,32.3,0.006351460000000001,-0.0895478,43.2,1.3459204621012224,13.995724409196717,3.900791037953958e-12,0.1771658642008649,432.9792586669269,6.286673488033272,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-435,Elin Energy (Sirius PV),Mono-c-Si,0,435.0,410.8,1.94,,,54.0,14.3,37.82,13.72,31.64,0.006492200000000001,-0.08861226000000001,43.2,1.3664415886860655,14.300059208315465,1.3646352038710116e-11,0.13107363950158565,31656.94291771975,15.472862429707963,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-BF-435,Elin Energy (Sirius PV),Mono-c-Si,1,435.0,411.3,1.94,,,54.0,14.3,37.82,13.72,31.64,0.0060489,-0.09144876,43.2,1.3525940237019403,14.300067140792388,1.0279074048178664e-11,0.14183332629300707,30208.427823615915,9.352052110743497,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-435,Elin Energy (Sirius PV),Mono-c-Si,0,435.0,410.8,1.94,,,54.0,14.3,37.82,13.72,31.64,0.006492200000000001,-0.08861226000000001,43.2,1.3664415886860655,14.300059208315465,1.3646352038710116e-11,0.13107363950158565,31656.94291771975,15.472862429707963,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435,Elin Energy (Sirius PV),Mono-c-Si,0,435.0,413.2,1.94,,,54.0,14.07,39.1,13.39,32.5,0.006387780000000001,-0.0900082,43.2,1.3537705095390729,14.076249710929494,3.999244538233329e-12,0.17417612753702946,392.1234359091614,6.458151371731583,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-435,Elin Energy (Sirius PV),Mono-c-Si,0,435.0,413.2,1.94,,,54.0,14.07,39.1,13.39,32.5,0.006387780000000001,-0.0900082,43.2,1.3537705095390729,14.076249710929494,3.999244538233329e-12,0.17417612753702946,392.1234359091614,6.458151371731583,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-435,Elin Energy (Sirius PV),Mono-c-Si,0,435.0,410.3,2.15,,,60.0,13.46,41.02,12.82,33.98,0.005868560000000001,-0.09007992000000001,43.1,1.4584038675287423,13.463733358070026,8.166326142296071e-12,0.1941532306569271,699.9884081262823,18.826899720482135,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-440,Elin Energy (Sirius PV),Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.81,39.3,13.04,33.76,0.0064354600000000005,-0.09329819999999998,43.1,1.3814951471373815,13.817829952533621,5.990168007283177e-12,0.0838382620904314,147.86889138021297,6.8966673910517144,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-440,Elin Energy (Sirius PV),Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.81,39.3,13.04,33.76,0.0064354600000000005,-0.09329819999999998,43.1,1.3814951471373815,13.817829952533621,5.990168007283177e-12,0.0838382620904314,147.86889138021297,6.8966673910517144,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-440,Elin Energy (Sirius PV),Mono-c-Si,0,440.0,414.6,2.15,,,60.0,13.56,41.12,12.92,34.08,0.00615624,-0.09634416000000001,43.2,1.4791866670927458,13.562837613194166,1.1426401534501264e-11,0.18873180019876654,901.8851123946727,14.320329754416186,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-440,Elin Energy (Sirius PV),Mono-c-Si,1,440.0,415.1,2.15,,,60.0,13.56,41.12,12.92,34.08,0.00573588,-0.09942816,43.2,1.4647455915335774,13.56329590149877,8.683223640971235e-12,0.19121919158942483,786.7141287415332,8.338707783816249,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-440,Elin Energy (Sirius PV),Mono-c-Si,0,440.0,414.6,2.15,,,60.0,13.56,41.12,12.92,34.08,0.00615624,-0.09634416000000001,43.2,1.4791866670927458,13.562837613194166,1.1426401534501264e-11,0.18873180019876654,901.8851123946727,14.320329754416186,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-445,Elin Energy (Sirius PV),Mono-c-Si,0,445.0,423.5,1.94,,,54.0,13.85,39.5,13.1,33.97,0.006454100000000001,-0.09377300000000001,43.1,1.3881571996133568,13.85680559073545,5.973601791759187e-12,0.0809404843116964,164.72129349291657,6.839317450835175,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-445,Elin Energy (Sirius PV),Mono-c-Si,0,445.0,423.5,1.94,,,54.0,13.85,39.5,13.1,33.97,0.006454100000000001,-0.09377300000000001,43.1,1.3881571996133568,13.85680559073545,5.973601791759187e-12,0.0809404843116964,164.72129349291657,6.839317450835175,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-445,Elin Energy (Sirius PV),Mono-c-Si,0,445.0,419.4,2.15,,,60.0,13.66,41.22,13.03,34.18,0.0062016400000000005,-0.09657846,43.2,1.4823869374120082,13.661693556931736,1.1439842739622728e-11,0.1863322681828513,1502.9308083012852,14.257410712456396,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-445,Elin Energy (Sirius PV),Mono-c-Si,1,445.0,420.0,2.15,,,60.0,13.66,41.22,13.03,34.18,0.00577818,-0.09966996,43.2,1.4679139511165633,13.662136906930883,8.692680614250426e-12,0.1888044008942622,1206.9164750701068,8.278149912669912,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-445,Elin Energy (Sirius PV),Mono-c-Si,0,445.0,419.4,2.15,,,60.0,13.66,41.22,13.03,34.18,0.0062016400000000005,-0.09657846,43.2,1.4823869374120082,13.661693556931736,1.1439842739622728e-11,0.1863322681828513,1502.9308083012852,14.257410712456396,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-450,Elin Energy (Sirius PV),Mono-c-Si,0,450.0,428.4,1.94,,,54.0,13.89,39.7,13.17,34.18,0.00647274,-0.0942478,43.1,1.394321211760881,13.895509404936512,5.902339281378026e-12,0.07817425551872637,197.08851013843005,6.697486233928264,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-450,Elin Energy (Sirius PV),Mono-c-Si,0,450.0,428.4,1.94,,,54.0,13.89,39.7,13.17,34.18,0.00647274,-0.0942478,43.1,1.394321211760881,13.895509404936512,5.902339281378026e-12,0.07817425551872637,197.08851013843005,6.697486233928264,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-450,Elin Energy (Sirius PV),Mono-c-Si,0,450.0,424.2,2.15,,,60.0,13.76,41.32,13.13,34.28,0.006247040000000001,-0.09681276000000001,43.2,1.4861022996365247,13.761366762946718,1.1553479001897018e-11,0.18394921409828888,1851.9241841717205,14.28003361699803,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-450,Elin Energy (Sirius PV),Mono-c-Si,1,450.0,424.8,2.15,,,60.0,13.76,41.32,13.13,34.28,0.005820479999999999,-0.09991176,43.2,1.4573635672698408,13.762246611417261,6.6710853544423696e-12,0.188830896481347,1156.5476583034733,5.894346558965136,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-450,Elin Energy (Sirius PV),Mono-c-Si,0,450.0,424.2,2.15,,,60.0,13.76,41.32,13.13,34.28,0.006247040000000001,-0.09681276000000001,43.2,1.4861022996365247,13.761366762946718,1.1553479001897018e-11,0.18394921409828888,1851.9241841717205,14.28003361699803,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-455,Elin Energy (Sirius PV),Mono-c-Si,0,455.0,433.2,1.94,,,54.0,13.94,39.9,13.25,34.34,0.00649604,-0.0947226,43.1,1.3995053650480032,13.944487089203704,5.722485492135508e-12,0.07966087083384024,247.48173219663232,6.383119110245088,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-455,Elin Energy (Sirius PV),Mono-c-Si,0,455.0,433.2,1.94,,,54.0,13.94,39.9,13.25,34.34,0.00649604,-0.0947226,43.1,1.3995053650480032,13.944487089203704,5.722485492135508e-12,0.07966087083384024,247.48173219663232,6.383119110245088,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-455,Elin Energy (Sirius PV),Mono-c-Si,0,455.0,429.0,2.15,,,60.0,13.86,41.42,13.23,34.38,0.006292440000000001,-0.09704706,43.2,1.4399413730746538,13.862581514687298,4.446963748682869e-12,0.190035139471757,1020.2874574997445,5.6170968636587295,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-455,Elin Energy (Sirius PV),Mono-c-Si,1,455.0,429.6,2.15,,,60.0,13.86,41.42,13.23,34.38,0.00586278,-0.10015356,43.2,1.4752751092792802,13.861479440388981,8.866507879257741e-12,0.18404986913224106,1724.2541962687637,8.321844718367567,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-455,Elin Energy (Sirius PV),Mono-c-Si,0,455.0,429.0,2.15,,,60.0,13.86,41.42,13.23,34.38,0.006292440000000001,-0.09704706,43.2,1.4399413730746538,13.862581514687298,4.446963748682869e-12,0.190035139471757,1020.2874574997445,5.6170968636587295,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-460,Elin Energy (Sirius PV),Mono-c-Si,0,460.0,438.1,1.94,,,54.0,13.99,40.1,13.34,34.5,0.00651934,-0.0951974,43.1,1.4042157006937352,13.993075413157545,5.501006721361904e-12,0.08122224292354499,369.47854597521683,5.9917837902875934,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-460,Elin Energy (Sirius PV),Mono-c-Si,0,460.0,438.1,1.94,,,54.0,13.99,40.1,13.34,34.5,0.00651934,-0.0951974,43.1,1.4042157006937352,13.993075413157545,5.501006721361904e-12,0.08122224292354499,369.47854597521683,5.9917837902875934,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-460,Elin Energy (Sirius PV),Mono-c-Si,0,460.0,433.9,2.15,,,60.0,13.96,41.52,13.33,34.48,0.006337840000000001,-0.09728136000000001,43.2,1.4419553971140544,13.962300126854418,4.351577535338604e-12,0.1879494169743642,1140.7083403179568,5.364748998691257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-460,Elin Energy (Sirius PV),Mono-c-Si,1,460.0,434.4,2.15,,,60.0,13.96,41.52,13.33,34.48,0.00590508,-0.10039536,43.2,1.4624296784068618,13.961659055494465,6.516320627027092e-12,0.18449832789225573,1552.4475911553614,5.563210957155862,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-460,Elin Energy (Sirius PV),Mono-c-Si,0,460.0,433.9,2.15,,,60.0,13.96,41.52,13.33,34.48,0.006337840000000001,-0.09728136000000001,43.2,1.4419553971140544,13.962300126854418,4.351577535338604e-12,0.1879494169743642,1140.7083403179568,5.364748998691257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-465,Elin Energy (Sirius PV),Mono-c-Si,0,465.0,443.0,1.94,,,54.0,14.05,40.3,13.42,34.65,0.006547300000000001,-0.0956722,43.1,1.4096978905581863,14.052322275748725,5.367812259533686e-12,0.08335706918362126,504.3185880896075,5.732672930842,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM54M-HC-N-465,Elin Energy (Sirius PV),Mono-c-Si,0,465.0,443.0,1.94,,,54.0,14.05,40.3,13.42,34.65,0.006547300000000001,-0.0956722,43.1,1.4096978905581863,14.052322275748725,5.367812259533686e-12,0.08335706918362126,504.3185880896075,5.732672930842,-0.2925,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-465,Elin Energy (Sirius PV),Mono-c-Si,0,465.0,438.7,2.15,,,60.0,14.06,41.62,13.43,34.58,0.00638324,-0.09751565999999999,43.2,1.4972603251479926,14.060420822458003,1.1898912122366886e-11,0.17700987781886313,5914.03970003057,14.349184363730064,-0.3321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Elin Energy (Sirius PV) ELNSM60M-HC-BF-465,Elin Energy (Sirius PV),Mono-c-Si,1,465.0,439.3,2.15,,,60.0,14.06,41.62,13.43,34.58,0.0059473799999999995,-0.10063715999999999,43.2,1.4826441015845067,14.060844767781969,9.042657099621548e-12,0.1794349099894463,2986.4478511901243,8.366352997745125,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-465,Elin Energy (Sirius PV),Mono-c-Si,0,465.0,438.7,2.15,,,60.0,14.06,41.62,13.43,34.58,0.00638324,-0.09751565999999999,43.2,1.4972603251479926,14.060420822458003,1.1898912122366886e-11,0.17700987781886313,5914.03970003057,14.349184363730064,-0.3321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Elin Energy (Sirius PV) ELNSM60M-HC-470,Elin Energy (Sirius PV),Mono-c-Si,0,470.0,443.5,2.15,,,60.0,14.16,41.72,13.53,34.68,0.00642864,-0.09774996000000001,43.2,1.500983476679451,14.160116761372763,1.2015554117365226e-11,0.17476417458881943,21194.182136785832,14.37263659752189,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-470,Elin Energy (Sirius PV),Mono-c-Si,1,470.0,444.1,2.15,,,60.0,14.16,41.72,13.53,34.68,0.00598968,-0.10087896,43.2,1.4863314216383656,14.160535815803211,9.131598240995469e-12,0.17717786825171822,4682.279200676882,8.388890653744477,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-470,Elin Energy (Sirius PV),Mono-c-Si,0,470.0,443.5,2.15,,,60.0,14.16,41.72,13.53,34.68,0.00642864,-0.09774996000000001,43.2,1.500983476679451,14.160116761372763,1.2015554117365226e-11,0.17476417458881943,21194.182136785832,14.37263659752189,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-475,Elin Energy (Sirius PV),Mono-c-Si,0,475.0,448.4,2.15,,,60.0,14.26,41.82,13.63,34.78,0.00647404,-0.09798426,43.2,1.4484718448924632,14.261468148308426,4.116952181415503e-12,0.18179783526077065,1765.7869795592958,4.696600242799967,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-BF-475,Elin Energy (Sirius PV),Mono-c-Si,1,475.0,449.0,2.15,,,60.0,14.26,41.82,13.63,34.78,0.00603198,-0.10112076,43.2,1.4900205646315718,14.260232366745043,9.221114625922469e-12,0.17495348142111566,10736.597585973599,8.411606314206026,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM60M-HC-LV-475,Elin Energy (Sirius PV),Mono-c-Si,0,475.0,448.4,2.15,,,60.0,14.26,41.82,13.63,34.78,0.00647404,-0.09798426,43.2,1.4484718448924632,14.261468148308426,4.116952181415503e-12,0.18179783526077065,1765.7869795592958,4.696600242799967,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-490,Elin Energy (Sirius PV),Mono-c-Si,0,490.0,461.8,2.36,,,66.0,13.8,45.25,13.16,37.23,0.006265200000000001,-0.10602075000000001,43.2,1.6214685895965257,13.801475842990152,1.0458930157400347e-11,0.2278229981660827,2130.279160179155,13.328025954463055,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-490,Elin Energy (Sirius PV),Mono-c-Si,1,490.0,462.5,2.355264,,,66.0,13.8,45.25,13.16,37.23,0.0058374,-0.1094145,43.2,1.605622032376881,13.801981947987988,7.937228899292e-12,0.2304876244947934,1604.850054635726,7.38456188596423,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-490,Elin Energy (Sirius PV),Mono-c-Si,0,490.0,461.8,2.36,,,66.0,13.8,45.25,13.16,37.23,0.006265200000000001,-0.10602075000000001,43.2,1.6214685895965257,13.801475842990152,1.0458930157400347e-11,0.2278229981660827,2130.279160179155,13.328025954463055,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-495,Elin Energy (Sirius PV),Mono-c-Si,0,495.0,466.7,2.36,,,66.0,13.85,45.45,13.24,37.39,0.006287900000000001,-0.10648935000000001,43.2,1.6284759042143087,13.8500031119775,1.0483174178576577e-11,0.22468706221282034,999999.6176750003,13.310008968258646,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-495,Elin Energy (Sirius PV),Mono-c-Si,1,495.0,467.3,2.355264,,,66.0,13.85,45.45,13.24,37.39,0.0058585500000000006,-0.1098981,43.2,1.6120114862379311,13.850003165746545,7.883051798836419e-12,0.22857017724878248,999999.6301487549,7.285023307074715,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-495,Elin Energy (Sirius PV),Mono-c-Si,0,495.0,466.7,2.36,,,66.0,13.85,45.45,13.24,37.39,0.006287900000000001,-0.10648935000000001,43.2,1.6284759042143087,13.8500031119775,1.0483174178576577e-11,0.22468706221282034,999999.6176750003,13.310008968258646,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-500,Elin Energy (Sirius PV),Mono-c-Si,0,500.0,471.5,2.36,,,66.0,13.9,45.65,13.32,37.55,0.006310600000000001,-0.10695795000000001,43.2,1.6371753921360075,13.90009137856128,1.0798766242351579e-11,0.22820287819808127,34712.98562246943,13.551725871633812,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-500,Elin Energy (Sirius PV),Mono-c-Si,1,500.0,472.1,2.355264,,,66.0,13.9,45.65,13.32,37.55,0.0058797,-0.1103817,43.2,1.6206178386496946,13.90000308040702,8.122495345174465e-12,0.22160809450568203,999997.3175826974,7.516324008316026,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-500,Elin Energy (Sirius PV),Mono-c-Si,0,500.0,471.5,2.36,,,66.0,13.9,45.65,13.32,37.55,0.006310600000000001,-0.10695795000000001,43.2,1.6371753921360075,13.90009137856128,1.0798766242351579e-11,0.22820287819808127,34712.98562246943,13.551725871633812,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-505,Elin Energy (Sirius PV),Mono-c-Si,0,505.0,476.3,2.36,,,66.0,13.95,45.85,13.39,37.71,0.0063333,-0.10742655000000001,43.2,1.645360285358038,13.950002968884565,1.1026046580684427e-11,0.21281336601969117,999972.3324597065,13.711292156142639,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-505,Elin Energy (Sirius PV),Mono-c-Si,1,505.0,477.0,2.355264,,,66.0,13.95,45.85,13.39,37.71,0.005900849999999999,-0.1108653,43.2,1.6286631957278581,13.950060020569573,8.28561840427339e-12,0.2311608090764805,53726.51577094216,7.6599504698685905,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-505,Elin Energy (Sirius PV),Mono-c-Si,0,505.0,476.3,2.36,,,66.0,13.95,45.85,13.39,37.71,0.0063333,-0.10742655000000001,43.2,1.645360285358038,13.950002968884565,1.1026046580684427e-11,0.21281336601969117,999972.3324597065,13.711292156142639,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-510,Elin Energy (Sirius PV),Mono-c-Si,0,510.0,481.1,2.36,,,66.0,14.0,46.05,13.47,37.87,0.006356000000000001,-0.10789515,43.2,1.654058541573943,14.00000326401739,1.1352797611498752e-11,0.2052405948299576,880330.7448337171,13.949405230346636,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-510,Elin Energy (Sirius PV),Mono-c-Si,1,510.0,481.8,2.355264,,,66.0,14.0,46.05,13.47,37.87,0.005922,-0.11134889999999999,43.2,1.6373489616963908,14.00000332328308,8.544975094098097e-12,0.2093020340511963,881738.2426551973,7.899909217623788,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-510,Elin Energy (Sirius PV),Mono-c-Si,0,510.0,481.1,2.36,,,66.0,14.0,46.05,13.47,37.87,0.006356000000000001,-0.10789515,43.2,1.654058541573943,14.00000326401739,1.1352797611498752e-11,0.2052405948299576,880330.7448337171,13.949405230346636,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-515,Elin Energy (Sirius PV),Mono-c-Si,0,515.0,486.0,2.36,,,66.0,14.05,46.25,13.55,38.03,0.006378700000000001,-0.10836375000000001,43.2,1.4195198985946236,14.109310165016735,9.990000002900059e-14,0.2684760535240543,999999.8869073146,-23.684322245081738,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-515,Elin Energy (Sirius PV),Mono-c-Si,1,515.0,486.6,2.355264,,,66.0,14.05,46.25,13.55,38.03,0.00594315,-0.1118325,43.2,1.6465984800674458,14.050818228566659,8.887666423316795e-12,0.2311662400383919,3969.4115106882837,8.218924311241873,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-515,Elin Energy (Sirius PV),Mono-c-Si,0,515.0,486.0,2.36,,,66.0,14.05,46.25,13.55,38.03,0.006378700000000001,-0.10836375000000001,43.2,1.4195198985946236,14.109310165016735,9.990000002900059e-14,0.2684760535240543,999999.8869073146,-23.684322245081738,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-520,Elin Energy (Sirius PV),Mono-c-Si,0,520.0,490.8,2.36,,,66.0,14.1,46.45,13.63,38.19,0.0064014,-0.10883235000000001,43.2,1.6079869154604767,14.100006263413771,4.015409166299525e-12,0.23883379459859594,537657.5773385776,4.572066467242898,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-520,Elin Energy (Sirius PV),Mono-c-Si,1,520.0,491.5,2.355264,,,66.0,14.1,46.45,13.63,38.19,0.005964299999999999,-0.1123161,43.2,1.629828802186202,14.100006169868728,5.913656758194109e-12,0.2352945352447704,537721.9938338039,4.632989071251605,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-520,Elin Energy (Sirius PV),Mono-c-Si,0,520.0,490.8,2.36,,,66.0,14.1,46.45,13.63,38.19,0.0064014,-0.10883235000000001,43.2,1.6079869154604767,14.100006263413771,4.015409166299525e-12,0.23883379459859594,537657.5773385776,4.572066467242898,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-525,Elin Energy (Sirius PV),Mono-c-Si,0,525.0,495.7,2.36,,,66.0,14.15,46.65,13.71,38.35,0.006424100000000001,-0.10930095,43.2,1.6166538340091485,14.150006251184323,4.157154932841126e-12,0.23882156788743644,540592.1405016168,4.841333717664753,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-BF-525,Elin Energy (Sirius PV),Mono-c-Si,1,525.0,496.3,2.355264,,,66.0,14.15,46.65,13.71,38.35,0.005985450000000001,-0.11279969999999999,43.2,1.6632320465242445,14.150002936293397,9.327174336355595e-12,0.18433782716937003,888334.7394173719,8.580637286614563,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM66M-HC-LV-525,Elin Energy (Sirius PV),Mono-c-Si,0,525.0,495.7,2.36,,,66.0,14.15,46.65,13.71,38.35,0.006424100000000001,-0.10930095,43.2,1.6166538340091485,14.150006251184323,4.157154932841126e-12,0.23882156788743644,540592.1405016168,4.841333717664753,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-525,Elin Energy (Sirius PV),Mono-c-Si,0,525.0,495.4,2.56,,,72.0,13.5,49.4,12.66,41.46,0.005886000000000001,-0.10848239999999999,43.1,1.779596934047175,13.516613096839917,1.1601224053225107e-11,0.18408570633287608,149.59023382158725,22.344012599510307,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-530,Elin Energy (Sirius PV),Mono-c-Si,0,530.0,499.5,2.56,,,72.0,13.61,49.3,12.2,41.05,0.00617894,-0.1155099,43.2,1.8308610118329158,13.6690609272697,2.550409745256698e-11,0.20333820038746253,46.85725469327087,22.302616327418036,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-530,Elin Energy (Sirius PV),Mono-c-Si,1,530.0,500.2,2.56,,,72.0,13.61,49.3,12.2,41.05,0.00575703,-0.11920739999999999,43.2,1.8132066787578223,13.670353580597109,1.961493573300171e-11,0.20661758488391674,46.59318147896797,16.03007646869767,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-530,Elin Energy (Sirius PV),Mono-c-Si,0,530.0,499.5,2.56,,,72.0,13.61,49.3,12.2,41.05,0.00617894,-0.1155099,43.2,1.8308610118329158,13.6690609272697,2.550409745256698e-11,0.20333820038746253,46.85725469327087,22.302616327418036,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-535,Elin Energy (Sirius PV),Mono-c-Si,0,535.0,504.3,2.56,,,72.0,13.71,49.4,12.6,41.3,0.00622434,-0.1157442,43.2,1.8152153790303183,13.7445943321931,1.985190248847134e-11,0.18978509074192687,75.21329170843562,19.65513517217195,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-535,Elin Energy (Sirius PV),Mono-c-Si,1,535.0,505.0,2.56,,,72.0,13.71,49.4,12.6,41.3,0.005799329999999999,-0.11944919999999999,43.2,1.7976247404070487,13.745499970938315,1.520448766199093e-11,0.19293844296958226,74.51234429095727,13.476286243649877,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-535,Elin Energy (Sirius PV),Mono-c-Si,0,535.0,504.3,2.56,,,72.0,13.71,49.4,12.6,41.3,0.00622434,-0.1157442,43.2,1.8152153790303183,13.7445943321931,1.985190248847134e-11,0.18978509074192687,75.21329170843562,19.65513517217195,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-540,Elin Energy (Sirius PV),Mono-c-Si,0,540.0,509.1,2.56,,,72.0,13.81,49.5,13.0,41.55,0.00626974,-0.1159785,43.2,1.8015459589391511,13.823128330695665,1.582322586047771e-11,0.17642547191160401,185.58610626117743,17.284952021728838,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-540,Elin Energy (Sirius PV),Mono-c-Si,1,540.0,509.8,2.56,,,72.0,13.81,49.5,13.0,41.55,0.0058416299999999996,-0.11969099999999999,43.2,1.784024674549159,13.823674907368174,1.207569857984111e-11,0.17946119756752715,181.23407184979996,11.192087209055485,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-540,Elin Energy (Sirius PV),Mono-c-Si,0,540.0,509.1,2.56,,,72.0,13.81,49.5,13.0,41.55,0.00626974,-0.1159785,43.2,1.8015459589391511,13.823128330695665,1.582322586047771e-11,0.17642547191160401,185.58610626117743,17.284952021728838,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-545,Elin Energy (Sirius PV),Mono-c-Si,0,545.0,514.0,2.56,,,72.0,13.9,49.6,13.04,41.8,0.006310600000000001,-0.11621280000000002,43.2,1.8116179072421985,13.914857206064372,1.7481551725432697e-11,0.16072653830208833,150.37140100831854,18.196166121903765,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-545,Elin Energy (Sirius PV),Mono-c-Si,1,545.0,514.7,2.56,,,72.0,13.9,49.6,13.04,41.8,0.0058797,-0.1199328,43.2,1.794024311582213,13.915429688805638,1.3359450351837821e-11,0.16377658950067736,147.53989078018512,12.069803741015695,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-545,Elin Energy (Sirius PV),Mono-c-Si,0,545.0,514.0,2.56,,,72.0,13.9,49.6,13.04,41.8,0.006310600000000001,-0.11621280000000002,43.2,1.8116179072421985,13.914857206064372,1.7481551725432697e-11,0.16072653830208833,150.37140100831854,18.196166121903765,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-550,Elin Energy (Sirius PV),Mono-c-Si,0,550.0,518.8,2.56,,,72.0,14.0,49.7,13.08,42.05,0.006356000000000001,-0.11644710000000001,43.2,1.8223667270720048,14.016514234873288,1.9486871098449465e-11,0.14490680878568382,122.84525098829522,19.197089712420638,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-550,Elin Energy (Sirius PV),Mono-c-Si,1,550.0,519.5,2.56,,,72.0,14.0,49.7,13.08,42.05,0.005922,-0.1201746,43.2,1.8046995240185115,14.017124198317658,1.491464083590186e-11,0.14797184133656563,120.97534335443568,13.034328080106482,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-550,Elin Energy (Sirius PV),Mono-c-Si,0,550.0,518.8,2.56,,,72.0,14.0,49.7,13.08,42.05,0.006356000000000001,-0.11644710000000001,43.2,1.8223667270720048,14.016514234873288,1.9486871098449465e-11,0.14490680878568382,122.84525098829522,19.197089712420638,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-555,Elin Energy (Sirius PV),Mono-c-Si,0,555.0,523.6,2.56,,,72.0,14.1,49.8,13.12,42.31,0.0064014,-0.1166814,43.2,1.8333928264705939,14.117390520702623,2.178391674693956e-11,0.12829169766533935,104.01718107417726,20.233744305205487,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-555,Elin Energy (Sirius PV),Mono-c-Si,1,555.0,524.3,2.56,,,72.0,14.1,49.8,13.12,42.31,0.005964299999999999,-0.12041639999999999,43.2,1.8156537826325303,14.11803764486311,1.669960395261686e-11,0.13137183893787327,102.69317009635543,14.03370754250164,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-555,Elin Energy (Sirius PV),Mono-c-Si,0,555.0,523.6,2.56,,,72.0,14.1,49.8,13.12,42.31,0.0064014,-0.1166814,43.2,1.8333928264705939,14.117390520702623,2.178391674693956e-11,0.12829169766533935,104.01718107417726,20.233744305205487,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-560,Elin Energy (Sirius PV),Mono-c-Si,0,560.0,528.5,2.56,,,72.0,14.2,49.9,13.16,42.56,0.0064468,-0.1169157,43.2,1.844269774507356,14.217693656006647,2.42672112311024e-11,0.11262715059682027,90.38864217187083,21.244545634586174,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-560,Elin Energy (Sirius PV),Mono-c-Si,1,560.0,529.2,2.56,,,72.0,14.2,49.9,13.16,42.56,0.006006599999999999,-0.1206582,43.2,1.826462570505722,14.218380555699305,1.8633077525290647e-11,0.11572116707932605,89.40102788698434,15.008572555501,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-560,Elin Energy (Sirius PV),Mono-c-Si,0,560.0,528.5,2.56,,,72.0,14.2,49.9,13.16,42.56,0.0064468,-0.1169157,43.2,1.844269774507356,14.217693656006647,2.42672112311024e-11,0.11262715059682027,90.38864217187083,21.244545634586174,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-565,Elin Energy (Sirius PV),Mono-c-Si,0,565.0,533.3,2.56,,,72.0,14.3,50.0,13.2,42.81,0.006492200000000001,-0.11715,43.2,1.8552093738483668,14.317336066084026,2.702456568225659e-11,0.0970377803122427,80.04354933502722,22.260069395168184,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-565,Elin Energy (Sirius PV),Mono-c-Si,1,565.0,534.0,2.56,,,72.0,14.3,50.0,13.2,42.81,0.0060489,-0.1209,43.2,1.8373367043931705,14.318063729646694,2.0784190103906813e-11,0.10014512549639218,79.27904837764021,15.988390681055703,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-565,Elin Energy (Sirius PV),Mono-c-Si,0,565.0,533.3,2.56,,,72.0,14.3,50.0,13.2,42.81,0.006492200000000001,-0.11715,43.2,1.8552093738483668,14.317336066084026,2.702456568225659e-11,0.0970377803122427,80.04354933502722,22.260069395168184,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-570,Elin Energy (Sirius PV),Mono-c-Si,0,570.0,538.1,2.56,,,72.0,14.4,50.1,13.24,43.06,0.006537600000000001,-0.11738430000000001,43.2,1.8662112012682759,14.416321848175787,3.0084843258908545e-11,0.08152281821663854,71.92375344463534,23.28022597885806,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-BF-570,Elin Energy (Sirius PV),Mono-c-Si,1,570.0,538.9,2.56,,,72.0,14.4,50.1,13.24,43.06,0.006091200000000001,-0.1211418,43.2,1.8482760353186667,14.417091299782184,2.317650640451577e-11,0.08464290101348386,71.31451625471715,16.973109656734817,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM72M-HC-LV-570,Elin Energy (Sirius PV),Mono-c-Si,0,570.0,538.1,2.56,,,72.0,14.4,50.1,13.24,43.06,0.006537600000000001,-0.11738430000000001,43.2,1.8662112012682759,14.416321848175787,3.0084843258908545e-11,0.08152281821663854,71.92375344463534,23.28022597885806,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-580,Elin Energy (Sirius PV),Mono-c-Si,0,580.0,546.8,2.77,,,78.0,13.81,53.43,12.96,44.81,0.00626974,-0.12518649,43.2,1.9465843043856952,13.825875148090779,1.6220270213251043e-11,0.19352959576371284,168.35393977198885,17.536611430151133,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-580,Elin Energy (Sirius PV),Mono-c-Si,1,580.0,547.5,2.77,,,78.0,13.81,53.43,12.96,44.81,0.0058416299999999996,-0.12919374,43.2,1.9276587296095427,13.826469928028464,1.2383316113647682e-11,0.19681905531371596,165.03236413580888,11.434539718574756,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-580,Elin Energy (Sirius PV),Mono-c-Si,0,580.0,546.8,2.77,,,78.0,13.81,53.43,12.96,44.81,0.00626974,-0.12518649,43.2,1.9465843043856952,13.825875148090779,1.6220270213251043e-11,0.19352959576371284,168.35393977198885,17.536611430151133,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-585,Elin Energy (Sirius PV),Mono-c-Si,0,585.0,551.6,2.77,,,78.0,13.87,53.63,13.01,45.01,0.00629698,-0.12565509,43.2,1.9550026354716805,13.886140799965068,1.654115852989413e-11,0.1905237258773996,163.71952390161135,17.685301379418807,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-585,Elin Energy (Sirius PV),Mono-c-Si,1,585.0,552.3,2.77,,,78.0,13.87,53.63,13.01,45.01,0.005867009999999999,-0.12967734,43.2,1.9359997118497472,13.88674031262216,1.2631097308948743e-11,0.19381601574534585,160.58410663846655,11.577753332435709,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-585,Elin Energy (Sirius PV),Mono-c-Si,0,585.0,551.6,2.77,,,78.0,13.87,53.63,13.01,45.01,0.00629698,-0.12565509,43.2,1.9550026354716805,13.886140799965068,1.654115852989413e-11,0.1905237258773996,163.71952390161135,17.685301379418807,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-590,Elin Energy (Sirius PV),Mono-c-Si,0,590.0,556.4,2.77,,,78.0,13.93,53.83,13.06,45.21,0.006324220000000001,-0.12612369,43.2,1.963422182969094,13.946391982924993,1.686615596146852e-11,0.18754057859093068,159.37304713454728,17.83304634593142,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-590,Elin Energy (Sirius PV),Mono-c-Si,1,590.0,557.2,2.77,,,78.0,13.93,53.83,13.06,45.21,0.00589239,-0.13016094,43.2,1.9443419750237068,13.946996249884675,1.2882117073035385e-11,0.19083566521445378,156.40749226567112,11.720065787587272,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-590,Elin Energy (Sirius PV),Mono-c-Si,0,590.0,556.4,2.77,,,78.0,13.93,53.83,13.06,45.21,0.006324220000000001,-0.12612369,43.2,1.963422182969094,13.946391982924993,1.686615596146852e-11,0.18754057859093068,159.37304713454728,17.83304634593142,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-595,Elin Energy (Sirius PV),Mono-c-Si,0,595.0,561.2,2.77,,,78.0,13.99,54.03,13.11,45.41,0.006351460000000001,-0.12659229,43.2,1.9718429921426939,14.006628875250136,1.7195294211012337e-11,0.1845798868251554,155.28847117466086,17.97986147844088,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-595,Elin Energy (Sirius PV),Mono-c-Si,1,595.0,562.0,2.77,,,78.0,13.99,54.03,13.11,45.41,0.005917769999999999,-0.13064454,43.2,1.9526855447091243,14.007237925809152,1.313639766375888e-11,0.18787774062842855,152.47829861143325,11.861488865020565,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-595,Elin Energy (Sirius PV),Mono-c-Si,0,595.0,561.2,2.77,,,78.0,13.99,54.03,13.11,45.41,0.006351460000000001,-0.12659229,43.2,1.9718429921426939,14.006628875250136,1.7195294211012337e-11,0.1845798868251554,155.28847117466086,17.97986147844088,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-600,Elin Energy (Sirius PV),Mono-c-Si,0,600.0,566.1,2.77,,,78.0,14.05,54.23,13.16,45.61,0.006378700000000001,-0.12706089,43.2,1.9802649871464963,14.06685164898238,1.7528576449648513e-11,0.18164140675053586,151.44285144953733,18.125748435737925,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-600,Elin Energy (Sirius PV),Mono-c-Si,1,600.0,566.8,2.77,,,78.0,14.05,54.23,13.16,45.61,0.00594315,-0.13112814,43.2,1.9610303000800515,14.067465474939015,1.3393934973039809e-11,0.18494200523826948,148.77552309166867,12.002018689971026,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-600,Elin Energy (Sirius PV),Mono-c-Si,0,600.0,566.1,2.77,,,78.0,14.05,54.23,13.16,45.61,0.006378700000000001,-0.12706089,43.2,1.9802649871464963,14.06685164898238,1.7528576449648513e-11,0.18164140675053586,151.44285144953733,18.125748435737925,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-605,Elin Energy (Sirius PV),Mono-c-Si,0,605.0,570.9,2.77,,,78.0,14.11,54.43,13.21,45.81,0.006405940000000001,-0.12752949,43.2,1.9886881594523145,14.127060469644833,1.7866021183482272e-11,0.17872488764572142,147.81587048441807,18.270715935303485,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-605,Elin Energy (Sirius PV),Mono-c-Si,1,605.0,571.7,2.77,,,78.0,14.11,54.43,13.21,45.81,0.00596853,-0.13161174,43.2,1.96937611381009,14.127679172777045,1.3654719434790682e-11,0.1820282313756963,145.27932855267653,12.14164802913079,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-605,Elin Energy (Sirius PV),Mono-c-Si,0,605.0,570.9,2.77,,,78.0,14.11,54.43,13.21,45.81,0.006405940000000001,-0.12752949,43.2,1.9886881594523145,14.127060469644833,1.7866021183482272e-11,0.17872488764572142,147.81587048441807,18.270715935303485,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-610,Elin Energy (Sirius PV),Mono-c-Si,0,610.0,575.8,2.77,,,78.0,14.17,54.63,13.26,46.01,0.00643318,-0.12799809,43.2,1.9971125388298387,14.187255525103525,1.8207655611373887e-11,0.1758300764965135,144.38924208399,18.414777898416343,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-610,Elin Energy (Sirius PV),Mono-c-Si,1,610.0,576.5,2.77,,,78.0,14.17,54.63,13.26,46.01,0.005993909999999999,-0.13209534,43.2,1.9777237515938182,14.187879068450757,1.3918917570364024e-11,0.17913603800470854,141.97370912660494,12.280484345772667,-0.3247,N,2025.7.3,6/23/2025,2.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-610,Elin Energy (Sirius PV),Mono-c-Si,0,610.0,575.8,2.77,,,78.0,14.17,54.63,13.26,46.01,0.00643318,-0.12799809,43.2,1.9971125388298387,14.187255525103525,1.8207655611373887e-11,0.1758300764965135,144.38924208399,18.414777898416343,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-615,Elin Energy (Sirius PV),Mono-c-Si,0,615.0,580.6,2.77,,,78.0,14.23,54.83,13.33,46.21,0.006460420000000001,-0.12846669,43.2,2.0040966792762496,14.246304865796473,1.8224394763412163e-11,0.17315352415155297,151.1189779843325,18.378090200104207,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-BF-615,Elin Energy (Sirius PV),Mono-c-Si,1,615.0,581.4,2.77,,,78.0,14.23,54.83,13.33,46.21,0.00601929,-0.13257894,43.2,1.9846393935252475,14.246911682762413,1.3930958055837597e-11,0.17645454987240347,148.47418119291578,12.245109896710412,-0.3247,N,2025.7.3,6/23/2025,4.0,first_pass +Elin Energy (Sirius PV) ELNSM78M-HC-LV-615,Elin Energy (Sirius PV),Mono-c-Si,0,615.0,580.6,2.77,,,78.0,14.23,54.83,13.33,46.21,0.006460420000000001,-0.12846669,43.2,2.0040966792762496,14.246304865796473,1.8224394763412163e-11,0.17315352415155297,151.1189779843325,18.378090200104207,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH345BB,ELITE Solar,Mono-c-Si,0,345.0,322.5,1.8,,,60.0,11.05,39.9,10.34,33.4,0.0052708500000000005,-0.10473750000000001,43.5,1.514735314446537,11.062993650129874,3.920296960120207e-11,0.17425845856476252,148.19207557513994,14.621639937436619,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH350BB,ELITE Solar,Mono-c-Si,0,350.0,327.3,1.8,,,60.0,11.15,40.1,10.42,33.6,0.00531855,-0.10526250000000001,43.5,1.5240840634257653,11.163691869521719,4.071033120340387e-11,0.1697932939809924,138.2714930746793,14.894306345040224,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH355BB,ELITE Solar,Mono-c-Si,0,355.0,332.0,1.8,,,60.0,11.25,40.3,10.51,33.8,0.00536625,-0.10578749999999999,43.5,1.5326983219901262,11.263761342929412,4.177581542609089e-11,0.1655239086023459,135.31702499729136,15.05329287041744,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH355WB,ELITE Solar,Mono-c-Si,0,355.0,332.6,1.8,,,60.0,11.25,40.3,10.51,33.8,0.00552375,-0.10977719999999998,43.5,1.5233600288382003,11.264082367855101,3.554714027460477e-11,0.16749608569044042,133.80782244561215,9.388869394388715,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH355WW,ELITE Solar,Mono-c-Si,0,355.0,332.6,1.8,,,60.0,11.25,40.3,10.51,33.8,0.00552375,-0.10977719999999998,43.5,1.5233600288382003,11.264082367855101,3.554714027460477e-11,0.16749608569044042,133.80782244561215,9.388869394388715,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH360BB,ELITE Solar,Mono-c-Si,0,360.0,336.8,1.8,,,60.0,11.35,40.5,10.59,34.0,0.00541395,-0.10631250000000002,43.5,1.542045660461588,11.364389131110658,4.334814461077241e-11,0.16119702215738577,127.1505694076516,15.320947792004397,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH360WB,ELITE Solar,Mono-c-Si,0,360.0,337.4,1.8,,,60.0,11.35,40.5,10.59,34.0,0.00557285,-0.110322,43.5,1.4818437429307412,11.366581564652268,1.488706194123243e-11,0.17390657953012134,119.03820432439011,1.876355434226573,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH360WW,ELITE Solar,Mono-c-Si,0,360.0,337.4,1.8,,,60.0,11.35,40.5,10.59,34.0,0.00557285,-0.110322,43.5,1.4818437429307412,11.366581564652268,1.488706194123243e-11,0.17390657953012134,119.03820432439011,1.876355434226573,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH365BB,ELITE Solar,Mono-c-Si,0,365.0,341.6,1.8,,,60.0,11.43,40.7,10.68,34.2,0.00545211,-0.10683750000000002,43.5,1.5492884176121564,11.443351891938109,4.344901463456606e-11,0.1575928342742708,134.90867938347392,15.271055482636111,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH365WB,ELITE Solar,Mono-c-Si,0,365.0,342.2,1.8,,,60.0,11.43,40.7,10.68,34.2,0.00561213,-0.1108668,43.5,1.5398589972146939,11.443670132512883,3.698252695007718e-11,0.15955514310293906,133.40875043751404,9.598884297587555,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH365WW,ELITE Solar,Mono-c-Si,0,365.0,342.2,1.8,,,60.0,11.43,40.7,10.68,34.2,0.00561213,-0.1108668,43.5,1.5398589972146939,11.443670132512883,3.698252695007718e-11,0.15955514310293906,133.40875043751404,9.598884297587555,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH370BB,ELITE Solar,Mono-c-Si,0,370.0,346.4,1.8,,,60.0,11.52,40.9,10.76,34.4,0.00549504,-0.1073625,43.5,1.5579486070533195,11.533418824777867,4.45471467456854e-11,0.15365454664912367,131.91172991121894,15.432716884466485,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH370WB,ELITE Solar,Mono-c-Si,0,370.0,347.0,1.8,,,60.0,11.52,40.9,10.76,34.4,0.005656319999999999,-0.11141159999999999,43.5,1.5484732947118847,11.533739126812455,3.792577259182106e-11,0.15561322213860063,130.47876576858815,9.754703558355521,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH370WW,ELITE Solar,Mono-c-Si,0,370.0,347.0,1.8,,,60.0,11.52,40.9,10.76,34.4,0.005656319999999999,-0.11141159999999999,43.5,1.5484732947118847,11.533739126812455,3.792577259182106e-11,0.15561322213860063,130.47876576858815,9.754703558355521,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH375WB,ELITE Solar,Mono-c-Si,0,375.0,351.8,1.8,,,60.0,11.6,41.1,10.84,34.6,0.0056955999999999994,-0.1119564,43.5,1.5564050271400454,11.613278871026926,3.8441793642716324e-11,0.1519867327740918,132.77078342623602,9.811525405606028,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M660BH375WW,ELITE Solar,Mono-c-Si,0,375.0,351.8,1.8,,,60.0,11.6,41.1,10.84,34.6,0.0056955999999999994,-0.1119564,43.5,1.5564050271400454,11.613278871026926,3.8441793642716324e-11,0.1519867327740918,132.77078342623602,9.811525405606028,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH385BB,ELITE Solar,Mono-c-Si,0,385.0,360.5,1.94,,,54.0,13.52,36.7,12.65,30.44,0.006111039999999999,-0.09747520000000001,43.2,1.385160062355177,13.538649922957216,4.1153910419914144e-11,0.15692072383776007,113.75753163277635,11.909730098401939,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH390GL,ELITE Solar,Mono-c-Si,0,390.0,363.3,2.04,,,72.0,10.2,49.5,9.45,41.3,0.0060588,-0.148401,43.6,1.9541748250710214,10.216853793833144,9.846763867489128e-11,0.23309863953848,141.07245999459155,8.583230172552094,-0.3755,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH390WW,ELITE Solar,Mono-c-Si,0,390.0,364.0,1.99,,,72.0,10.12,49.3,9.49,41.1,0.00594044,-0.1480479,43.4,1.927713680881197,10.129937792834642,7.764913738738277e-11,0.24161160890215216,246.04150755298514,6.372383507780958,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH390BB,ELITE Solar,Mono-c-Si,0,390.0,365.3,1.94,,,54.0,13.61,36.85,12.73,30.64,0.006151719999999999,-0.0978736,43.2,1.3928289777648524,13.628394257168182,4.3013225124001666e-11,0.14964479011552428,110.72290617281496,12.252456193897407,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH390TB,ELITE Solar,Mono-c-Si,1,390.0,365.7,2.56,,,72.0,13.61,36.85,12.73,30.64,0.00412383,-0.09249349999999999,43.3,1.310530943888,13.63262094678602,8.144508783458044e-12,0.16405154243412295,98.70238934932016,4.0239951465522195,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH390TW,ELITE Solar,Mono-c-Si,1,390.0,365.7,2.56,,,72.0,13.61,36.85,12.73,30.64,0.00412383,-0.09249349999999999,43.3,1.310530943888,13.63262094678602,8.144508783458044e-12,0.16405154243412295,98.70238934932016,4.0239951465522195,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH395GL,ELITE Solar,Mono-c-Si,0,395.0,368.1,2.04,,,72.0,10.24,49.6,9.52,41.5,0.006082560000000001,-0.14870080000000002,43.6,1.9575328742335323,10.254082210505404,9.847990182192871e-11,0.21912161845989578,159.33616429377963,8.53787367529624,-0.3755,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH395WW,ELITE Solar,Mono-c-Si,0,395.0,368.7,1.99,,,72.0,10.23,49.5,9.55,41.4,0.006005010000000001,-0.14864850000000002,43.4,1.9434993163707157,10.242034977513237,8.667532499566641e-11,0.22298191906187137,189.53961646245546,7.246275289661835,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH395BB,ELITE Solar,Mono-c-Si,0,395.0,370.1,1.94,,,54.0,13.7,36.98,12.81,30.84,0.006192399999999999,-0.09821888,43.2,1.400132290252665,13.717927166736967,4.526695069658433e-11,0.14088294468971818,107.66321226528237,12.659391660644484,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH400GL,ELITE Solar,Mono-c-Si,0,400.0,372.9,2.04,,,72.0,10.34,49.7,9.6,41.7,0.00614196,-0.1490006,43.6,1.965903925697357,10.354068835076687,1.0507972004086993e-10,0.20307004623782735,149.24791542813998,9.028649004921181,-0.3755,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH400WW,ELITE Solar,Mono-c-Si,0,400.0,373.5,1.99,,,72.0,10.36,49.8,9.6,41.7,0.00608132,-0.1495494,43.4,1.9642499577727641,10.375934131810318,9.773153825100242e-11,0.21404165605440392,139.16488275429097,8.209670896239821,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH400BB,ELITE Solar,Mono-c-Si,0,400.0,374.9,1.94,,,54.0,13.79,37.07,12.9,31.01,0.006233079999999999,-0.09845792,43.2,1.4054515069103215,13.806735574619301,4.724225370216593e-11,0.13185111653059117,108.64442678538741,12.988341022985106,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH400TB,ELITE Solar,Mono-c-Si,1,400.0,375.3,2.56,,,72.0,13.79,37.07,12.9,31.01,0.00417837,-0.09304570000000001,43.3,1.3222033900549217,13.810771533634748,8.952303826551733e-12,0.1462953601916838,97.12394707976956,4.718944044467514,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH400TW,ELITE Solar,Mono-c-Si,1,400.0,375.3,2.56,,,72.0,13.79,37.07,12.9,31.01,0.00417837,-0.09304570000000001,43.3,1.3222033900549217,13.810771533634748,8.952303826551733e-12,0.1462953601916838,97.12394707976956,4.718944044467514,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH405GL,ELITE Solar,Mono-c-Si,0,405.0,377.6,2.04,,,72.0,10.44,49.8,9.62,42.1,0.0062013599999999995,-0.1493004,43.6,1.986180243902971,10.454709642184001,1.2933182817361544e-10,0.16152335594766726,114.6393525294541,10.818761249845057,-0.3755,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH405WW,ELITE Solar,Mono-c-Si,0,405.0,378.3,1.99,,,72.0,10.48,50.1,9.65,42.0,0.006151760000000001,-0.1504503,43.4,1.9841187952925097,10.499004782138636,1.0872115984542198e-10,0.20555050553439577,113.34880381468822,9.067976578655141,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH405TB,ELITE Solar,Mono-c-Si,1,405.0,380.0,2.56,,,72.0,13.87,37.23,12.98,31.21,0.00420261,-0.0934473,43.3,1.3290440346058678,13.889813123672855,9.224715419037639e-12,0.1402771956072941,98.19979619790045,4.924648990783742,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH405TW,ELITE Solar,Mono-c-Si,1,405.0,380.0,2.56,,,72.0,13.87,37.23,12.98,31.21,0.00420261,-0.0934473,43.3,1.3290440346058678,13.889813123672855,9.224715419037639e-12,0.1402771956072941,98.19979619790045,4.924648990783742,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH410GL,ELITE Solar,Mono-c-Si,0,410.0,382.4,2.04,,,72.0,10.54,49.9,9.65,42.5,0.00626076,-0.14960020000000002,43.6,1.9595312577480046,10.55473995649225,8.740458017420744e-11,0.1310344386179529,93.69790149252321,7.318904146989318,-0.3755,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH410WW,ELITE Solar,Mono-c-Si,0,410.0,383.1,1.99,,,72.0,10.6,50.4,9.69,42.3,0.0062222,-0.15135120000000002,43.4,1.9946256083354783,10.622697804137914,1.0710155227865007e-10,0.19924215444402715,93.04718831121873,8.865275566957338,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH410TB,ELITE Solar,Mono-c-Si,1,410.0,384.8,2.56,,,72.0,13.95,37.32,13.04,31.45,0.00422685,-0.09367320000000001,43.3,1.3364369148043875,13.968967934194445,1.0109171446253088e-11,0.12531337286726096,92.16193683917353,5.668052608400063,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH410TW,ELITE Solar,Mono-c-Si,1,410.0,384.8,2.56,,,72.0,13.95,37.32,13.04,31.45,0.00422685,-0.09367320000000001,43.3,1.3364369148043875,13.968967934194445,1.0109171446253088e-11,0.12531337286726096,92.16193683917353,5.668052608400063,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH415TB,ELITE Solar,Mono-c-Si,1,415.0,389.6,2.56,,,72.0,14.02,37.45,13.13,31.61,0.00424806,-0.09399950000000001,43.3,1.3409328994181993,14.037058304882036,1.0147075699220504e-11,0.12089064366399227,99.35845554286483,5.649111787623421,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH415TW,ELITE Solar,Mono-c-Si,1,415.0,389.6,2.56,,,72.0,14.02,37.45,13.13,31.61,0.00424806,-0.09399950000000001,43.3,1.3409328994181993,14.037058304882036,1.0147075699220504e-11,0.12089064366399227,99.35845554286483,5.649111787623421,-0.3243,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH415GB,ELITE Solar,Mono-c-Si,0,415.0,392.7,1.95,,,54.0,13.45,38.26,12.64,32.84,0.005944900000000001,-0.08688846,43.6,1.362999478893208,13.459495781488165,8.46293993575194e-12,0.0827023688221392,117.14116143351752,15.298173142838758,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH415GL,ELITE Solar,Mono-c-Si,0,415.0,392.7,1.95,,,54.0,13.45,38.26,12.64,32.84,0.005944900000000001,-0.08688846,43.6,1.362999478893208,13.459495781488165,8.46293993575194e-12,0.0827023688221392,117.14116143351752,15.298173142838758,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M754BH420TB,ELITE Solar,Mono-c-Si,1,420.0,394.4,2.56,,,72.0,14.1,37.58,13.21,31.8,0.0042723,-0.09432579999999999,43.3,1.3470114435673424,14.11599093805211,1.0513104528361353e-11,0.11371903889603038,100.27169423219374,5.904507129142489,-0.3243,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M754BH420TW,ELITE Solar,Mono-c-Si,1,420.0,394.4,2.56,,,72.0,14.1,37.58,13.21,31.8,0.0042723,-0.09432579999999999,43.3,1.3470114435673424,14.11599093805211,1.0513104528361353e-11,0.11371903889603038,100.27169423219374,5.904507129142489,-0.3243,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-N754TBH420GB,ELITE Solar,Mono-c-Si,0,420.0,397.5,1.95,,,54.0,13.52,38.46,12.72,33.02,0.00597584,-0.08734266,43.6,1.369564271167238,13.528969480088728,8.42071508212783e-12,0.08211440254563682,123.77380993223217,15.196472678306494,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH420GL,ELITE Solar,Mono-c-Si,0,420.0,397.5,1.95,,,54.0,13.52,38.46,12.72,33.02,0.00597584,-0.08734266,43.6,1.369564271167238,13.528969480088728,8.42071508212783e-12,0.08211440254563682,123.77380993223217,15.196472678306494,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH425GB,ELITE Solar,Mono-c-Si,0,425.0,402.4,1.95,,,54.0,13.58,38.66,12.8,33.21,0.006002360000000001,-0.08779686,43.6,1.375850305843501,13.588036167440947,8.332538571280246e-12,0.08080749588665306,136.55337617173797,15.04642906806148,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH425GL,ELITE Solar,Mono-c-Si,0,425.0,402.4,1.95,,,54.0,13.58,38.66,12.8,33.21,0.006002360000000001,-0.08779686,43.6,1.375850305843501,13.588036167440947,8.332538571280246e-12,0.08080749588665306,136.55337617173797,15.04642906806148,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH430GB,ELITE Solar,Mono-c-Si,0,430.0,407.2,1.95,,,54.0,13.65,38.86,12.88,33.39,0.006033300000000001,-0.08825105999999999,43.6,1.3824204672725444,13.657532467311238,8.293179508082146e-12,0.08023687760309076,145.40167724106507,14.948017840732698,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH430GL,ELITE Solar,Mono-c-Si,0,430.0,407.2,1.95,,,54.0,13.65,38.86,12.88,33.39,0.006033300000000001,-0.08825105999999999,43.6,1.3824204672725444,13.657532467311238,8.293179508082146e-12,0.08023687760309076,145.40167724106507,14.948017840732698,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH430GB,ELITE Solar,Mono-c-Si,0,430.0,408.3,2.0,,,48.0,15.65,34.89,14.84,29.0,0.0066669,-0.07585086,43.2,1.1987973113569552,15.661886388085534,3.546801891636477e-12,0.1414285539264015,186.20937298561572,10.740848399318985,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH430GL,ELITE Solar,Mono-c-Si,0,430.0,408.3,2.0,,,48.0,15.65,34.89,14.84,29.0,0.0066669,-0.07585086,43.2,1.1987973113569552,15.661886388085534,3.546801891636477e-12,0.1414285539264015,186.20937298561572,10.740848399318985,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH435TW,ELITE Solar,Mono-c-Si,0,435.0,406.2,2.15,,,72.0,11.36,49.1,10.66,40.8,0.00518016,-0.13585970000000003,43.0,1.90271687762065,11.371606562870653,6.924895370490408e-11,0.23165275771165703,226.73166930038607,13.558001821198156,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH435WW,ELITE Solar,Mono-c-Si,0,435.0,406.6,2.15,,,72.0,11.39,48.7,10.64,40.9,0.0055811,-0.137821,43.3,1.8490763081948576,11.390005033587352,4.152406166481355e-11,0.19203501627474442,434544.89445047866,6.396064449352393,-0.3708,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH435GB,ELITE Solar,Mono-c-Si,0,435.0,413.0,1.95,,,54.0,13.72,39.06,12.97,33.55,0.005995640000000001,-0.08620542000000002,43.4,1.3700367581093844,13.727328923574085,5.596431913412646e-12,0.08475384883401053,158.66215479858903,14.503451292765012,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH435GL,ELITE Solar,Mono-c-Si,0,435.0,412.1,1.95,,,54.0,13.72,39.06,12.97,33.55,0.006064240000000001,-0.08870526000000001,43.6,1.3881027501763845,13.72682668835416,8.115102499424132e-12,0.0815278844997341,163.85141946971422,14.68634563135042,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH435GB,ELITE Solar,Mono-c-Si,0,435.0,413.1,2.0,,,48.0,15.72,35.09,14.91,29.18,0.00669672,-0.07628566000000002,43.2,1.2058022053361814,15.731595149098712,3.5749800095860323e-12,0.14055973157439838,190.56236065588485,10.771457309263143,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH435GL,ELITE Solar,Mono-c-Si,0,435.0,413.1,2.0,,,48.0,15.72,35.09,14.91,29.18,0.00669672,-0.07628566000000002,43.2,1.2058022053361814,15.731595149098712,3.5749800095860323e-12,0.14055973157439838,190.56236065588485,10.771457309263143,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH440TW,ELITE Solar,Mono-c-Si,0,440.0,411.0,2.15,,,72.0,11.48,49.2,10.73,41.0,0.005234880000000001,-0.13613640000000002,43.0,1.9133284533136257,11.493999144044237,7.625599124479276e-11,0.2165560821071061,177.58684751351547,14.365557584597775,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH440WW,ELITE Solar,Mono-c-Si,0,440.0,411.4,2.15,,,72.0,11.46,48.9,10.71,41.1,0.0056154,-0.13838699999999998,43.3,1.8936553696735976,11.472335246827518,6.818611807883961e-11,0.18119927036612699,168.34228676309294,10.778100500781497,-0.3708,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH440GB,ELITE Solar,Mono-c-Si,0,440.0,416.9,1.95,,,54.0,13.78,39.26,13.05,33.73,0.006090760000000001,-0.08915946,43.6,1.3942086220901637,13.785994870465961,8.003979610399363e-12,0.08111420914183853,186.45170238575201,14.506993370388786,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH440GL,ELITE Solar,Mono-c-Si,0,440.0,416.9,1.95,,,54.0,13.78,39.26,13.05,33.73,0.006090760000000001,-0.08915946,43.6,1.3942086220901637,13.785994870465961,8.003979610399363e-12,0.08111420914183853,186.45170238575201,14.506993370388786,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH440GB,ELITE Solar,Mono-c-Si,0,440.0,418.0,2.0,,,48.0,15.79,35.29,14.98,29.38,0.00672654,-0.07672046,43.2,1.2131839764495365,15.801241941466708,3.635658672139658e-12,0.13818286926645745,194.08636098866705,10.884364429726025,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH440GL,ELITE Solar,Mono-c-Si,0,440.0,418.0,2.0,,,48.0,15.79,35.29,14.98,29.38,0.00672654,-0.07672046,43.2,1.2131839764495365,15.801241941466708,3.635658672139658e-12,0.13818286926645745,194.08636098866705,10.884364429726025,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH445TW,ELITE Solar,Mono-c-Si,0,445.0,415.8,2.15,,,72.0,11.52,49.4,10.8,41.2,0.00525312,-0.1366898,43.0,1.9189657884295792,11.531766339480388,7.46187256836117e-11,0.21354850776439233,209.07767060162277,14.120644778199635,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH445WW,ELITE Solar,Mono-c-Si,0,445.0,416.2,2.15,,,72.0,11.53,49.1,10.78,41.3,0.0056497000000000006,-0.138953,43.3,1.8662019777429093,11.530004751874518,4.320011933063198e-11,0.18431806459204955,447239.98786399484,6.631468058469694,-0.3708,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH445GB,ELITE Solar,Mono-c-Si,0,445.0,421.8,1.95,,,54.0,13.84,39.46,13.13,33.9,0.00611728,-0.08961366,43.6,1.4001262149338813,13.845220229589179,7.86577245725248e-12,0.08156747309848451,216.25367441856275,14.294031132967724,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH445GL,ELITE Solar,Mono-c-Si,0,445.0,421.8,1.95,,,54.0,13.84,39.46,13.13,33.9,0.00611728,-0.08961366,43.6,1.4001262149338813,13.845220229589179,7.86577245725248e-12,0.08156747309848451,216.25367441856275,14.294031132967724,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH445GB,ELITE Solar,Mono-c-Si,0,445.0,422.9,2.0,,,48.0,15.86,35.49,15.05,29.57,0.0067563599999999994,-0.07715526000000002,43.2,1.2203761575270777,15.870928974908278,3.68019855986308e-12,0.13658325687893738,198.20801821344506,10.954663549705185,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH445GL,ELITE Solar,Mono-c-Si,0,445.0,422.9,2.0,,,48.0,15.86,35.49,15.05,29.57,0.0067563599999999994,-0.07715526000000002,43.2,1.2203761575270777,15.870928974908278,3.68019855986308e-12,0.13658325687893738,198.20801821344506,10.954663549705185,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH450TW,ELITE Solar,Mono-c-Si,0,450.0,420.6,2.15,,,72.0,11.58,49.6,10.87,41.4,0.005280480000000001,-0.1372432,43.0,1.8758759323090257,11.592125646542788,3.733025345259817e-11,0.22014386128728836,210.23752650297712,7.874093762263824,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH450WW,ELITE Solar,Mono-c-Si,0,450.0,421.0,2.15,,,72.0,11.6,49.3,10.85,41.5,0.005684,-0.13951899999999998,43.3,1.8747631343759963,11.600004629364358,4.405160873693424e-11,0.18053462502658663,452382.3265482894,6.7475354685290565,-0.3708,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH450GB,ELITE Solar,Mono-c-Si,0,450.0,427.6,1.95,,,54.0,13.9,39.66,13.21,34.08,0.006074300000000001,-0.08752961999999999,43.4,1.3879893647472417,13.90480748489768,5.3536898684600535e-12,0.08435218571715178,243.88956147100845,13.93714676881506,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH450GL,ELITE Solar,Mono-c-Si,0,450.0,427.6,1.95,,,54.0,13.9,39.66,13.21,34.08,0.006074300000000001,-0.08752961999999999,43.4,1.3879893647472417,13.90480748489768,5.3536898684600535e-12,0.08435218571715178,243.88956147100845,13.93714676881506,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH450GB,ELITE Solar,Mono-c-Si,0,450.0,427.7,2.0,,,48.0,15.93,35.69,15.12,29.77,0.006786179999999999,-0.07759006,43.2,1.2277558844983314,15.940590097482149,3.741341120149632e-12,0.13424795101468506,201.9405034976842,11.06484495820743,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH450GL,ELITE Solar,Mono-c-Si,0,450.0,427.7,2.0,,,48.0,15.93,35.69,15.12,29.77,0.006786179999999999,-0.07759006,43.2,1.2277558844983314,15.940590097482149,3.741341120149632e-12,0.13424795101468506,201.9405034976842,11.06484495820743,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH455TW,ELITE Solar,Mono-c-Si,0,455.0,425.4,2.15,,,72.0,11.65,49.8,10.93,41.6,0.0053124,-0.1377966,43.0,1.8984428668720983,11.65000561036048,4.719526185987739e-11,0.21295336603044282,442210.96936212893,9.809477736845913,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M672BH455WW,ELITE Solar,Mono-c-Si,0,455.0,425.8,2.15,,,72.0,11.66,49.5,10.92,41.7,0.0057134,-0.140085,43.3,1.917129659964445,11.670755080213816,6.975917159836908e-11,0.17053788438024642,184.88674336573942,10.818977620881592,-0.3708,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH455GB,ELITE Solar,Mono-c-Si,0,455.0,432.4,1.95,,,54.0,13.97,39.86,13.29,34.24,0.006104890000000001,-0.08797102000000001,43.4,1.3941248950834155,13.97438218580675,5.292617446379654e-12,0.08548798193584585,272.52773957861734,13.777214286998964,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N754TBH455GL,ELITE Solar,Mono-c-Si,0,455.0,432.4,1.95,,,54.0,13.97,39.86,13.29,34.24,0.006104890000000001,-0.08797102000000001,43.4,1.3941248950834155,13.97438218580675,5.292617446379654e-12,0.08548798193584585,272.52773957861734,13.777214286998964,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH455GB,ELITE Solar,Mono-c-Si,0,455.0,432.6,2.0,,,48.0,16.0,35.89,15.19,29.96,0.006816,-0.07802486,43.2,1.2349464679518303,16.010289985439975,3.7861101853045686e-12,0.1326820650456416,206.30865387518827,11.133017825085886,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH455GL,ELITE Solar,Mono-c-Si,0,455.0,432.6,2.0,,,48.0,16.0,35.89,15.19,29.96,0.006816,-0.07802486,43.2,1.2349464679518303,16.010289985439975,3.7861101853045686e-12,0.1326820650456416,206.30865387518827,11.133017825085886,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH460GB,ELITE Solar,Mono-c-Si,0,460.0,437.4,2.0,,,48.0,16.07,36.09,15.26,30.15,0.00684582,-0.07845966000000001,43.2,1.2421364445327305,16.07999563491779,3.830954887046351e-12,0.1311309526537915,210.8194656969415,11.200063240935721,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-NR48TBH460GL,ELITE Solar,Mono-c-Si,0,460.0,437.4,2.0,,,48.0,16.07,36.09,15.26,30.15,0.00684582,-0.07845966000000001,43.2,1.2421364445327305,16.07999563491779,3.830954887046351e-12,0.1311309526537915,210.8194656969415,11.200063240935721,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-NR48TBH465GB,ELITE Solar,Mono-c-Si,0,465.0,442.3,2.0,,,48.0,16.14,36.29,15.33,30.34,0.006875640000000001,-0.07889446,43.2,1.249325389583327,16.149707016976066,3.875842850842587e-12,0.12959427817116614,215.47831412456776,11.266640565667156,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR48TBH465GL,ELITE Solar,Mono-c-Si,0,465.0,442.3,2.0,,,48.0,16.14,36.29,15.33,30.34,0.006875640000000001,-0.07889446,43.2,1.249325389583327,16.149707016976066,3.875842850842587e-12,0.12959427817116614,215.47831412456776,11.266640565667156,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH515BB,ELITE Solar,Mono-c-Si,0,515.0,482.4,2.56,,,72.0,13.51,48.85,12.61,40.86,0.00610652,-0.12974560000000002,43.2,1.8540422560214562,13.528186559016536,4.747430772679048e-11,0.17746851261407612,131.83360426398045,13.230446816532465,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH520BB,ELITE Solar,Mono-c-Si,0,520.0,487.2,2.56,,,72.0,13.58,49.0,12.69,41.0,0.00613816,-0.130144,43.2,1.858995510920736,13.597249339672892,4.7285476078295254e-11,0.17591702688220184,138.49534474768453,13.141743057125897,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH525BB,ELITE Solar,Mono-c-Si,0,525.0,492.0,2.56,,,72.0,13.65,49.15,12.76,41.15,0.0061698000000000005,-0.1305424,43.2,1.8649246609017143,13.666865533991611,4.770713709913989e-11,0.17338153129656136,140.32511053202182,13.174546105699065,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH525GL,ELITE Solar,Mono-c-Si,0,525.0,493.9,2.56,,,72.0,13.65,49.15,12.76,41.15,0.0056511,-0.12430035,43.4,1.8033361590783992,13.669048745727855,1.9365363799890055e-11,0.18413895464901633,131.95077379518673,10.58666099664898,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH530BB,ELITE Solar,Mono-c-Si,0,530.0,496.9,2.56,,,72.0,13.72,49.3,12.83,41.31,0.006201440000000001,-0.1309408,43.2,1.8710893661380052,13.73641217427618,4.828888791553685e-11,0.16997487129093927,142.0930104609815,13.237372833196376,-0.3609,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH530GL,ELITE Solar,Mono-c-Si,0,530.0,498.7,2.56,,,72.0,13.72,49.3,12.83,41.31,0.0056800800000000005,-0.1246797,43.4,1.8092834746086983,13.738571307910455,1.9601906920442613e-11,0.18071695445645514,133.5089933718038,10.648459390611817,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH530TB,ELITE Solar,Mono-c-Si,1,530.0,495.4,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005158720000000001,-0.1415896,43.4,1.888184922346985,13.735841295561363,6.132423347206979e-11,0.16702710468948026,144.66063654085997,6.80265435007689,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH530TW,ELITE Solar,Mono-c-Si,1,530.0,495.4,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005158720000000001,-0.1415896,43.4,1.888184922346985,13.735841295561363,6.132423347206979e-11,0.16702710468948026,144.66063654085997,6.80265435007689,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH530WB,ELITE Solar,Mono-c-Si,0,530.0,495.7,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005048960000000001,-0.1356736,43.6,1.869096268395765,13.736479468774704,4.6948747744151884e-11,0.1703191942380964,141.79943514041616,9.123596750269808,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH530WW,ELITE Solar,Mono-c-Si,0,530.0,495.7,2.56,,,72.0,13.72,49.3,12.83,41.31,0.005048960000000001,-0.1356736,43.6,1.869096268395765,13.736479468774704,4.6948747744151884e-11,0.1703191942380964,141.79943514041616,9.123596750269808,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH535BB,ELITE Solar,Mono-c-Si,0,535.0,501.7,2.56,,,72.0,13.79,49.45,12.91,41.47,0.006233079999999999,-0.13133920000000002,43.2,1.876523543508348,13.805376348657934,4.841978440354916e-11,0.1667069513711155,149.5081133059965,13.210876516554736,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH535GL,ELITE Solar,Mono-c-Si,0,535.0,503.5,2.56,,,72.0,13.79,49.45,12.91,41.47,0.005709059999999999,-0.12505905000000003,43.4,1.8145453376076581,13.807472596866768,1.9654676705442528e-11,0.1774158355131097,140.02293993393235,10.622086459078833,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH535TB,ELITE Solar,Mono-c-Si,1,535.0,500.2,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00518504,-0.14202040000000002,43.4,1.8944176670174329,13.80540248776825,6.207377196480134e-11,0.1636604852217208,146.5268563133717,6.862246691937211,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH535TW,ELITE Solar,Mono-c-Si,1,535.0,500.2,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00518504,-0.14202040000000002,43.4,1.8944176670174329,13.80540248776825,6.207377196480134e-11,0.1636604852217208,146.5268563133717,6.862246691937211,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH535WB,ELITE Solar,Mono-c-Si,0,535.0,500.5,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00507472,-0.13608640000000002,43.6,1.875258582805055,13.806033252642225,4.752088980302346e-11,0.16694848468066048,143.59030390054542,9.184211644244307,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH535WW,ELITE Solar,Mono-c-Si,0,535.0,500.5,2.56,,,72.0,13.79,49.45,12.9,41.47,0.00507472,-0.13608640000000002,43.6,1.875258582805055,13.806033252642225,4.752088980302346e-11,0.16694848468066048,143.59030390054542,9.184211644244307,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH540GL,ELITE Solar,Mono-c-Si,0,540.0,508.3,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00573804,-0.12543840000000003,43.4,1.821398960079552,13.877561612844893,2.0145253404739037e-11,0.17309999427559483,136.6142125321453,10.800496901439608,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH540TB,ELITE Solar,Mono-c-Si,1,540.0,505.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00521136,-0.14245120000000003,43.4,1.9008928935341285,13.874899036346813,6.303591005096584e-11,0.15943986058414367,148.32076631161073,6.950044601793042,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH540TW,ELITE Solar,Mono-c-Si,1,540.0,505.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00521136,-0.14245120000000003,43.4,1.9008928935341285,13.874899036346813,6.303591005096584e-11,0.15943986058414367,148.32076631161073,6.950044601793042,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH540WB,ELITE Solar,Mono-c-Si,0,540.0,505.3,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00510048,-0.13649920000000001,43.6,1.8816573621106027,13.875520891334256,4.825499435399979e-11,0.16272540607990535,145.31215353115385,9.273538796144265,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH540WW,ELITE Solar,Mono-c-Si,0,540.0,505.3,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00510048,-0.13649920000000001,43.6,1.8816573621106027,13.875520891334256,4.825499435399979e-11,0.16272540607990535,145.31215353115385,9.273538796144265,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH545GL,ELITE Solar,Mono-c-Si,0,545.0,513.2,2.56,,,72.0,13.93,49.75,13.04,41.8,0.00576702,-0.12581775,43.4,1.8273472990066029,13.94710902734325,2.0386949554088895e-11,0.1697930473669837,138.24381176000696,10.861202580192298,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH545TB,ELITE Solar,Mono-c-Si,1,545.0,509.8,2.56,,,72.0,13.93,49.75,13.04,41.8,0.005237680000000001,-0.142882,43.4,1.9071263690630793,13.944476983961318,6.379693912914697e-11,0.15615061166153227,150.250773687383,7.008901886626917,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH545TW,ELITE Solar,Mono-c-Si,1,545.0,509.8,2.56,,,72.0,13.93,49.75,13.04,41.8,0.005237680000000001,-0.142882,43.4,1.9071263690630793,13.944476983961318,6.379693912914697e-11,0.15615061166153227,150.250773687383,7.008901886626917,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH545WB,ELITE Solar,Mono-c-Si,0,545.0,510.1,2.56,,,72.0,13.93,49.75,13.04,41.8,0.00512624,-0.136912,43.6,1.8878203817506956,13.945091424541328,4.883586100754821e-11,0.15943214764458818,147.16237184141428,9.333405671812171,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH545WW,ELITE Solar,Mono-c-Si,0,545.0,510.1,2.56,,,72.0,13.93,49.75,13.04,41.8,0.00512624,-0.136912,43.6,1.8878203817506956,13.945091424541328,4.883586100754821e-11,0.15943214764458818,147.16237184141428,9.333405671812171,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH550GL,ELITE Solar,Mono-c-Si,0,550.0,518.0,2.56,,,72.0,14.0,49.9,13.11,41.96,0.005796000000000001,-0.1261971,43.4,1.8332960691342315,14.01666419853659,2.0630205492704105e-11,0.16652158230975134,139.89884698094215,10.9215921808076,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH550TB,ELITE Solar,Mono-c-Si,1,550.0,514.6,2.56,,,72.0,14.0,49.9,13.11,41.96,0.0052640000000000004,-0.14331280000000002,43.4,1.9133603276024922,14.014062668425538,6.456293321388674e-11,0.15289665107101227,152.215288768733,7.067454389293538,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH550TW,ELITE Solar,Mono-c-Si,1,550.0,514.6,2.56,,,72.0,14.0,49.9,13.11,41.96,0.0052640000000000004,-0.14331280000000002,43.4,1.9133603276024922,14.014062668425538,6.456293321388674e-11,0.15289665107101227,152.215288768733,7.067454389293538,-0.3722,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH550WB,ELITE Solar,Mono-c-Si,0,550.0,514.9,2.56,,,72.0,14.0,49.9,13.11,41.96,0.005152,-0.1373248,43.6,1.8939835706037638,14.014669727703346,4.942028998461802e-11,0.15617427318168828,149.04433725459532,9.392925373603234,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH550WW,ELITE Solar,Mono-c-Si,0,550.0,514.9,2.56,,,72.0,14.0,49.9,13.11,41.96,0.005152,-0.1373248,43.6,1.8939835706037638,14.014669727703346,4.942028998461802e-11,0.15617427318168828,149.04433725459532,9.392925373603234,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH555GL,ELITE Solar,Mono-c-Si,0,555.0,522.8,2.56,,,72.0,14.07,50.05,13.18,42.11,0.0058249800000000004,-0.12657644999999998,43.4,1.839026252369544,14.086303122620437,2.0807933491695633e-11,0.16415481983217625,141.6696896791733,10.952588508153811,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-M772BH555TB,ELITE Solar,Mono-c-Si,1,555.0,519.5,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005290320000000001,-0.1437436,43.4,1.9193534673145207,14.08372580888763,6.51215428786837e-11,0.15055328435867654,154.32858992288678,7.097521550989205,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH555TW,ELITE Solar,Mono-c-Si,1,555.0,519.5,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005290320000000001,-0.1437436,43.4,1.9193534673145207,14.08372580888763,6.51215428786837e-11,0.15055328435867654,154.32858992288678,7.097521550989205,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH555WB,ELITE Solar,Mono-c-Si,0,555.0,519.7,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005177760000000001,-0.1377376,43.6,1.899912513862717,14.084326930518184,4.984713604029814e-11,0.153825371508525,151.06676060567008,9.423523052285747,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH555WW,ELITE Solar,Mono-c-Si,0,555.0,519.7,2.56,,,72.0,14.07,50.05,13.18,42.11,0.005177760000000001,-0.1377376,43.6,1.899912513862717,14.084326930518184,4.984713604029814e-11,0.153825371508525,151.06676060567008,9.423523052285747,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-M772BH560GL,ELITE Solar,Mono-c-Si,0,560.0,527.6,2.56,,,72.0,14.14,50.2,13.25,42.27,0.00585396,-0.1269558,43.4,1.844975994724086,14.155872542256272,2.1053787070966988e-11,0.16094790244334098,143.37988906559585,11.012455764498164,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH560GB,ELITE Solar,Mono-c-Si,0,560.0,530.2,2.58,,,72.0,13.52,51.28,12.72,44.03,0.00597584,-0.11645688000000001,43.6,1.8261510878641263,13.52894686321131,8.429133729914724e-12,0.10918831635399645,164.99928568937818,15.205922984507671,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH560GL,ELITE Solar,Mono-c-Si,0,560.0,530.2,2.58,,,72.0,13.52,51.28,12.72,44.03,0.00597584,-0.11645688000000001,43.6,1.8261510878641263,13.52894686321131,8.429133729914724e-12,0.10918831635399645,164.99928568937818,15.205922984507671,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH565GB,ELITE Solar,Mono-c-Si,0,565.0,535.0,2.58,,,72.0,13.57,51.48,12.78,44.21,0.005997940000000001,-0.11691107999999999,43.6,1.832558756972016,13.578474990699208,8.37797798067013e-12,0.10866147195963632,173.98676043996426,15.108684084216838,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH565GL,ELITE Solar,Mono-c-Si,0,565.0,535.0,2.58,,,72.0,13.57,51.48,12.78,44.21,0.005997940000000001,-0.11691107999999999,43.6,1.832558756972016,13.578474990699208,8.37797798067013e-12,0.10866147195963632,173.98676043996426,15.108684084216838,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH570GB,ELITE Solar,Mono-c-Si,0,570.0,539.8,2.58,,,72.0,13.62,51.68,12.85,44.38,0.00602004,-0.11736528,43.6,1.8381013395158734,13.627718682760534,8.22579149923533e-12,0.10916436116608816,192.6259502014173,14.892412940724453,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH570GL,ELITE Solar,Mono-c-Si,0,570.0,539.8,2.58,,,72.0,13.62,51.68,12.85,44.38,0.00602004,-0.11736528,43.6,1.8381013395158734,13.627718682760534,8.22579149923533e-12,0.10916436116608816,192.6259502014173,14.892412940724453,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH575GB,ELITE Solar,Mono-c-Si,0,575.0,544.7,2.58,,,72.0,13.67,51.88,12.91,44.55,0.006042140000000001,-0.11781948,43.6,1.8443213798107203,13.67730685047002,8.153809408325094e-12,0.10951942765967347,204.89410378162364,14.770262900287678,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH575GL,ELITE Solar,Mono-c-Si,0,575.0,544.7,2.58,,,72.0,13.67,51.88,12.91,44.55,0.006042140000000001,-0.11781948,43.6,1.8443213798107203,13.67730685047002,8.153809408325094e-12,0.10951942765967347,204.89410378162364,14.770262900287678,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH580GB,ELITE Solar,Mono-c-Si,0,580.0,549.5,2.58,,,72.0,13.72,52.08,12.97,44.72,0.006064240000000001,-0.11827368,43.6,1.8505443691272698,13.726892088803842,8.083370521774722e-12,0.10987017164795375,218.7172569177171,14.649447122544036,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH580GL,ELITE Solar,Mono-c-Si,0,580.0,549.5,2.58,,,72.0,13.72,52.08,12.97,44.72,0.006064240000000001,-0.11827368,43.6,1.8505443691272698,13.726892088803842,8.083370521774722e-12,0.10987017164795375,218.7172569177171,14.649447122544036,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH585GB,ELITE Solar,Mono-c-Si,0,585.0,554.4,2.58,,,72.0,13.76,52.28,13.03,44.9,0.00608192,-0.11872788000000001,43.6,1.8563363309843044,13.766091156159776,7.962677524008257e-12,0.10955468660629393,247.48544454174765,14.47238428047956,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH585GL,ELITE Solar,Mono-c-Si,0,585.0,554.4,2.58,,,72.0,13.76,52.28,13.03,44.9,0.00608192,-0.11872788000000001,43.6,1.8563363309843044,13.766091156159776,7.962677524008257e-12,0.10955468660629393,247.48544454174765,14.47238428047956,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH590GB,ELITE Solar,Mono-c-Si,0,590.0,559.2,2.58,,,72.0,13.81,52.48,13.09,45.08,0.006104020000000001,-0.11918207999999998,43.6,1.8627598665604104,13.815634358956453,7.918927187006433e-12,0.10903328004251438,267.2441731610787,14.38188767878812,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH590GL,ELITE Solar,Mono-c-Si,0,590.0,559.2,2.58,,,72.0,13.81,52.48,13.09,45.08,0.006104020000000001,-0.11918207999999998,43.6,1.8627598665604104,13.815634358956453,7.918927187006433e-12,0.10903328004251438,267.2441731610787,14.38188767878812,-0.3065,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH595GB,ELITE Solar,Mono-c-Si,0,595.0,565.3,2.58,,,72.0,13.86,52.68,13.15,45.25,0.00605682,-0.11626476000000001,43.4,1.844715933101858,13.865657320509866,5.416525704490862e-12,0.11365019412992972,278.4342320166805,14.082136194898261,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH595GL,ELITE Solar,Mono-c-Si,0,595.0,565.3,2.58,,,72.0,13.86,52.68,13.15,45.25,0.00605682,-0.11626476000000001,43.4,1.844715933101858,13.865657320509866,5.416525704490862e-12,0.11365019412992972,278.4342320166805,14.082136194898261,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH595GB,ELITE Solar,Mono-c-Si,0,595.0,565.3,2.7,,,66.0,15.76,48.1,14.89,39.97,0.006713759999999999,-0.1045694,43.2,1.6551152922412196,15.776482365552269,3.7120215959452025e-12,0.19431781279099,185.8015297349085,11.112762396880148,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-NR66TBH595GL,ELITE Solar,Mono-c-Si,0,595.0,565.3,2.7,,,66.0,15.76,48.1,14.89,39.97,0.006713759999999999,-0.1045694,43.2,1.6551152922412196,15.776482365552269,3.7120215959452025e-12,0.19431781279099,185.8015297349085,11.112762396880148,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-N772TBH600GB,ELITE Solar,Mono-c-Si,0,600.0,570.2,2.58,,,72.0,13.9,52.88,13.21,45.42,0.006074300000000001,-0.11670616000000002,43.4,1.8502782874934744,13.904867444105841,5.32303594043121e-12,0.11418252671399715,326.07196855216205,13.88317341029306,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH600GL,ELITE Solar,Mono-c-Si,0,600.0,570.2,2.58,,,72.0,13.9,52.88,13.21,45.42,0.006074300000000001,-0.11670616000000002,43.4,1.8502782874934744,13.904867444105841,5.32303594043121e-12,0.11418252671399715,326.07196855216205,13.88317341029306,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH600GB,ELITE Solar,Mono-c-Si,0,600.0,570.1,2.7,,,66.0,15.82,48.3,14.95,40.14,0.00673932,-0.1050042,43.2,1.6619088107094317,15.836254919960066,3.7213238942096755e-12,0.1940999914705883,188.90661262101577,11.099765949219675,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH600GL,ELITE Solar,Mono-c-Si,0,600.0,570.1,2.7,,,66.0,15.82,48.3,14.95,40.14,0.00673932,-0.1050042,43.2,1.6619088107094317,15.836254919960066,3.7213238942096755e-12,0.1940999914705883,188.90661262101577,11.099765949219675,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH605GB,ELITE Solar,Mono-c-Si,0,605.0,575.0,2.7,,,66.0,15.88,48.5,15.01,40.31,0.006764880000000001,-0.105439,43.2,1.668702280548733,15.896028329144967,3.730632405147131e-12,0.19388392902694074,192.08969125952132,11.086868983791382,-0.2956,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-NR66TBH605GL,ELITE Solar,Mono-c-Si,0,605.0,575.0,2.7,,,66.0,15.88,48.5,15.01,40.31,0.006764880000000001,-0.105439,43.2,1.668702280548733,15.896028329144967,3.730632405147131e-12,0.19388392902694074,192.08969125952132,11.086868983791382,-0.2956,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N772TBH610GB,ELITE Solar,Mono-c-Si,0,610.0,579.9,2.58,,,72.0,14.0,53.28,13.33,45.77,0.006118000000000001,-0.11758896000000002,43.4,1.8628105620384554,14.003962931500022,5.253665195907587e-12,0.11398390046822252,402.67529496312477,13.683549714032388,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N772TBH610GL,ELITE Solar,Mono-c-Si,0,610.0,579.9,2.58,,,72.0,14.0,53.28,13.33,45.77,0.006118000000000001,-0.11758896000000002,43.4,1.8628105620384554,14.003962931500022,5.253665195907587e-12,0.11398390046822252,402.67529496312477,13.683549714032388,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH610GB,ELITE Solar,Mono-c-Si,0,610.0,579.8,2.7,,,66.0,15.94,48.7,15.07,40.48,0.006790439999999999,-0.10587380000000002,43.2,1.6754957163421222,15.955802593860286,3.739947912505732e-12,0.19366960255282847,195.35359151360024,11.074071701463325,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH610GL,ELITE Solar,Mono-c-Si,0,610.0,579.8,2.7,,,66.0,15.94,48.7,15.07,40.48,0.006790439999999999,-0.10587380000000002,43.2,1.6754957163421222,15.955802593860286,3.739947912505732e-12,0.19366960255282847,195.35359151360024,11.074071701463325,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH615GB,ELITE Solar,Mono-c-Si,0,615.0,583.7,2.8,,,78.0,13.59,55.89,12.83,47.94,0.00593883,-0.12334923000000002,43.4,1.9603076085966957,13.59821804777189,5.531838040649199e-12,0.12800136769967851,211.6729711067616,14.490151413498523,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH615GL,ELITE Solar,Mono-c-Si,0,615.0,583.7,2.8,,,78.0,13.59,55.89,12.83,47.94,0.00593883,-0.12334923000000002,43.4,1.9603076085966957,13.59821804777189,5.531838040649199e-12,0.12800136769967851,211.6729711067616,14.490151413498523,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH615GB,ELITE Solar,Mono-c-Si,0,615.0,584.7,2.7,,,66.0,16.0,48.9,15.13,40.65,0.006816,-0.1063086,43.2,1.6822891322341247,16.015577696822454,3.749270975298569e-12,0.19345699749172662,198.70151532710625,11.061352705410371,-0.2956,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-NR66TBH615GL,ELITE Solar,Mono-c-Si,0,615.0,584.7,2.7,,,66.0,16.0,48.9,15.13,40.65,0.006816,-0.1063086,43.2,1.6822891322341247,16.015577696822454,3.749270975298569e-12,0.19345699749172662,198.70151532710625,11.061352705410371,-0.2956,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N778TBH620GB,ELITE Solar,Mono-c-Si,0,620.0,588.6,2.8,,,78.0,13.64,56.09,12.89,48.12,0.005960680000000001,-0.12379063000000001,43.4,1.9665839365308604,13.64772052251384,5.499350941836266e-12,0.12742366914291653,225.12191967605716,14.395115318445924,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH620GL,ELITE Solar,Mono-c-Si,0,620.0,588.6,2.8,,,78.0,13.64,56.09,12.89,48.12,0.005960680000000001,-0.12379063000000001,43.4,1.9665839365308604,13.64772052251384,5.499350941836266e-12,0.12742366914291653,225.12191967605716,14.395115318445924,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH620GB,ELITE Solar,Mono-c-Si,0,620.0,589.6,2.7,,,66.0,16.06,49.1,15.19,40.82,0.006841559999999999,-0.10674340000000002,43.2,1.6890824690112485,16.075353630037487,3.758598435763973e-12,0.19324607639930258,202.13669232858038,11.048770920882296,-0.2956,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-NR66TBH620GL,ELITE Solar,Mono-c-Si,0,620.0,589.6,2.7,,,66.0,16.06,49.1,15.19,40.82,0.006841559999999999,-0.10674340000000002,43.2,1.6890824690112485,16.075353630037487,3.758598435763973e-12,0.19324607639930258,202.13669232858038,11.048770920882296,-0.2956,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N778TBH625GB,ELITE Solar,Mono-c-Si,0,625.0,593.4,2.8,,,78.0,13.69,56.29,12.95,48.27,0.00598253,-0.12423203,43.4,1.972296719853364,13.697359242605847,5.423189263391655e-12,0.12947379563555092,240.85308224699912,14.22437438790366,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH625GL,ELITE Solar,Mono-c-Si,0,625.0,593.4,2.8,,,78.0,13.69,56.29,12.95,48.27,0.00598253,-0.12423203,43.4,1.972296719853364,13.697359242605847,5.423189263391655e-12,0.12947379563555092,240.85308224699912,14.22437438790366,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH625GB,ELITE Solar,Mono-c-Si,0,625.0,594.4,2.7,,,66.0,16.12,49.3,15.25,40.99,0.00686712,-0.1071782,43.2,1.6958757492616132,16.135130344958434,3.767930982955434e-12,0.19303684125257833,205.66311480906472,11.03625873375183,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH625GL,ELITE Solar,Mono-c-Si,0,625.0,594.4,2.7,,,66.0,16.12,49.3,15.25,40.99,0.00686712,-0.1071782,43.2,1.6958757492616132,16.135130344958434,3.767930982955434e-12,0.19303684125257833,205.66311480906472,11.03625873375183,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH630GB,ELITE Solar,Mono-c-Si,0,630.0,598.3,2.8,,,78.0,13.74,56.49,13.01,48.43,0.00600438,-0.12467343000000002,43.4,1.9782028052815788,13.746940785867988,5.363392222344287e-12,0.13063295553152485,258.6013811255725,14.080913875196131,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH630GL,ELITE Solar,Mono-c-Si,0,630.0,598.3,2.8,,,78.0,13.74,56.49,13.01,48.43,0.00600438,-0.12467343000000002,43.4,1.9782028052815788,13.746940785867988,5.363392222344287e-12,0.13063295553152485,258.6013811255725,14.080913875196131,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH630GB,ELITE Solar,Mono-c-Si,0,630.0,599.3,2.7,,,66.0,16.18,49.5,15.31,41.15,0.00689268,-0.107613,43.2,1.7024795101057768,16.19494504760481,3.765151832963823e-12,0.19357148703872884,209.56685746360634,10.99421999298265,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH630GL,ELITE Solar,Mono-c-Si,0,630.0,599.3,2.7,,,66.0,16.18,49.5,15.31,41.15,0.00689268,-0.107613,43.2,1.7024795101057768,16.19494504760481,3.765151832963823e-12,0.19357148703872884,209.56685746360634,10.99421999298265,-0.2956,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH635GB,ELITE Solar,Mono-c-Si,0,635.0,603.1,2.8,,,78.0,13.79,56.69,13.07,48.59,0.0060262300000000005,-0.12511482999999998,43.4,1.9841129802969766,13.796512778835591,5.304946304935966e-12,0.13178002805253156,279.0278367425735,13.938990754124818,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH635GL,ELITE Solar,Mono-c-Si,0,635.0,603.1,2.8,,,78.0,13.79,56.69,13.07,48.59,0.0060262300000000005,-0.12511482999999998,43.4,1.9841129802969766,13.796512778835591,5.304946304935966e-12,0.13178002805253156,279.0278367425735,13.938990754124818,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH635GB,ELITE Solar,Mono-c-Si,0,635.0,604.2,2.7,,,66.0,16.24,49.7,15.37,41.32,0.006918239999999999,-0.10804780000000001,43.2,1.7092727143817918,16.254722248916362,3.774514752187808e-12,0.19336262189620942,213.29682725033734,10.982016094708113,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-NR66TBH635GL,ELITE Solar,Mono-c-Si,0,635.0,604.2,2.7,,,66.0,16.24,49.7,15.37,41.32,0.006918239999999999,-0.10804780000000001,43.2,1.7092727143817918,16.254722248916362,3.774514752187808e-12,0.19336262189620942,213.29682725033734,10.982016094708113,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-N778TBH640GB,ELITE Solar,Mono-c-Si,0,640.0,608.0,2.8,,,78.0,13.84,56.89,13.13,48.75,0.00604808,-0.12555623000000002,43.4,1.9900271800979772,13.846075359948465,5.247811235928732e-12,0.1329152024906558,302.7880522725918,13.798580349605462,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH640GL,ELITE Solar,Mono-c-Si,0,640.0,608.0,2.8,,,78.0,13.84,56.89,13.13,48.75,0.00604808,-0.12555623000000002,43.4,1.9900271800979772,13.846075359948465,5.247811235928732e-12,0.1329152024906558,302.7880522725918,13.798580349605462,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-NR66TBH640GB,ELITE Solar,Mono-c-Si,0,640.0,609.0,2.7,,,66.0,16.3,49.9,15.43,41.48,0.0069438,-0.1084826,43.2,1.7158764606045518,16.31453508711979,3.771840642170738e-12,0.19389181708536649,217.434996901298,10.940529251432107,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-NR66TBH640GL,ELITE Solar,Mono-c-Si,0,640.0,609.0,2.7,,,66.0,16.3,49.9,15.43,41.48,0.0069438,-0.1084826,43.2,1.7158764606045518,16.31453508711979,3.771840642170738e-12,0.19389181708536649,217.434996901298,10.940529251432107,-0.2956,N,2025.7.3,6/23/2025,2.0,first_pass +ELITE Solar ET-N778TBH645GB,ELITE Solar,Mono-c-Si,0,645.0,612.8,2.8,,,78.0,13.89,57.09,13.19,48.91,0.00606993,-0.12599763000000003,43.4,1.9959453366355113,13.89562866350035,5.191947896594799e-12,0.13403866485799476,330.77071624045675,13.659658081224453,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH645GL,ELITE Solar,Mono-c-Si,0,645.0,612.8,2.8,,,78.0,13.89,57.09,13.19,48.91,0.00606993,-0.12599763000000003,43.4,1.9959453366355113,13.89562866350035,5.191947896594799e-12,0.13403866485799476,330.77071624045675,13.659658081224453,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH650GB,ELITE Solar,Mono-c-Si,0,650.0,617.7,2.8,,,78.0,13.93,57.29,13.25,49.07,0.0060874100000000006,-0.12643903,43.4,2.001218039728045,13.934781649711741,5.090436297135021e-12,0.13536443100670292,394.34643494899115,13.439552529033849,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH650GL,ELITE Solar,Mono-c-Si,0,650.0,617.7,2.8,,,78.0,13.93,57.29,13.25,49.07,0.0060874100000000006,-0.12643903,43.4,2.001218039728045,13.934781649711741,5.090436297135021e-12,0.13536443100670292,394.34643494899115,13.439552529033849,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH655GB,ELITE Solar,Mono-c-Si,0,655.0,622.6,2.8,,,78.0,13.98,57.49,13.31,49.22,0.006109260000000001,-0.12688043000000002,43.4,2.0069590925645793,13.984332612280998,5.024417874786907e-12,0.1373135078121801,443.06822770596983,13.27929008037524,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH655GL,ELITE Solar,Mono-c-Si,0,655.0,622.6,2.8,,,78.0,13.98,57.49,13.31,49.22,0.006109260000000001,-0.12688043000000002,43.4,2.0069590925645793,13.984332612280998,5.024417874786907e-12,0.1373135078121801,443.06822770596983,13.27929008037524,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH660GB,ELITE Solar,Mono-c-Si,0,660.0,627.4,2.8,,,78.0,14.03,57.69,13.37,49.37,0.00613111,-0.12732183,43.4,2.0127044585724287,14.033867706355725,4.959953380908041e-12,0.1392436239121794,505.10247400442586,13.120685837608521,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N778TBH660GL,ELITE Solar,Mono-c-Si,0,660.0,627.4,2.8,,,78.0,14.03,57.69,13.37,49.37,0.00613111,-0.12732183,43.4,2.0127044585724287,14.033867706355725,4.959953380908041e-12,0.1392436239121794,505.10247400442586,13.120685837608521,-0.2974,N,2025.7.3,6/23/2025,4.0,first_pass +ELITE Solar ET-N866TBH685GB,ELITE Solar,Mono-c-Si,0,685.0,650.0,3.11,,,66.0,18.22,47.96,17.34,39.52,0.00832654,-0.1081498,43.4,1.6540590866761262,18.228083199957982,4.629296848317697e-12,0.18755912665152777,422.76911604874766,7.681916428401411,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH685GL,ELITE Solar,Mono-c-Si,0,685.0,650.0,3.11,,,66.0,18.22,47.96,17.34,39.52,0.00832654,-0.1081498,43.4,1.6540590866761262,18.228083199957982,4.629296848317697e-12,0.18755912665152777,422.76911604874766,7.681916428401411,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH690GB,ELITE Solar,Mono-c-Si,0,690.0,654.8,3.11,,,66.0,18.26,48.16,17.38,39.73,0.00834482,-0.1086008,43.4,1.6617511377051448,18.267935904830818,4.704309819245458e-12,0.18496694463720675,425.5968908343011,7.8054578665986725,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH690GL,ELITE Solar,Mono-c-Si,0,690.0,654.8,3.11,,,66.0,18.26,48.16,17.38,39.73,0.00834482,-0.1086008,43.4,1.6617511377051448,18.267935904830818,4.704309819245458e-12,0.18496694463720675,425.5968908343011,7.8054578665986725,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH695GB,ELITE Solar,Mono-c-Si,0,695.0,659.7,3.11,,,66.0,18.3,48.36,17.41,39.94,0.0083631,-0.1090518,43.4,1.6698561087976347,18.308691563740318,4.811052684117113e-12,0.18239027785776135,384.02089615933795,7.98886387915367,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH695GL,ELITE Solar,Mono-c-Si,0,695.0,659.7,3.11,,,66.0,18.3,48.36,17.41,39.94,0.0083631,-0.1090518,43.4,1.6698561087976347,18.308691563740318,4.811052684117113e-12,0.18239027785776135,384.02089615933795,7.98886387915367,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH700GB,ELITE Solar,Mono-c-Si,0,700.0,664.5,3.11,,,66.0,18.34,48.56,17.45,40.14,0.008381379999999999,-0.10950280000000001,43.4,1.6773541994574939,18.348531391445988,4.87134669089453e-12,0.18047337135333705,387.9650421041782,8.080407739584903,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH700GL,ELITE Solar,Mono-c-Si,0,700.0,664.5,3.11,,,66.0,18.34,48.56,17.45,40.14,0.008381379999999999,-0.10950280000000001,43.4,1.6773541994574939,18.348531391445988,4.87134669089453e-12,0.18047337135333705,387.9650421041782,8.080407739584903,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH705GB,ELITE Solar,Mono-c-Si,0,705.0,669.4,3.11,,,66.0,18.38,48.76,17.48,40.35,0.00839966,-0.1099538,43.4,1.6854624718093794,18.3892456494109,4.980432459637107e-12,0.17791447104090283,353.68721469937134,8.261597782922212,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH705GL,ELITE Solar,Mono-c-Si,0,705.0,669.4,3.11,,,66.0,18.38,48.76,17.48,40.35,0.00839966,-0.1099538,43.4,1.6854624718093794,18.3892456494109,4.980432459637107e-12,0.17791447104090283,353.68721469937134,8.261597782922212,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH710GB,ELITE Solar,Mono-c-Si,0,710.0,674.3,3.11,,,66.0,18.42,48.96,17.51,40.55,0.00841794,-0.11040480000000001,43.4,1.6933802564028368,18.429939304133836,5.07453865549564e-12,0.17601375621762416,326.19722220091796,8.412270158078764,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH710GL,ELITE Solar,Mono-c-Si,0,710.0,674.3,3.11,,,66.0,18.42,48.96,17.51,40.55,0.00841794,-0.11040480000000001,43.4,1.6933802564028368,18.429939304133836,5.07453865549564e-12,0.17601375621762416,326.19722220091796,8.412270158078764,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH715GB,ELITE Solar,Mono-c-Si,0,715.0,679.1,3.11,,,66.0,18.46,49.16,17.55,40.75,0.00843622,-0.1108558,43.4,1.700878358461843,18.469760022482863,5.136272459200213e-12,0.17412294207258677,329.33423317448216,8.500978318896191,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH715GL,ELITE Solar,Mono-c-Si,0,715.0,679.1,3.11,,,66.0,18.46,49.16,17.55,40.75,0.00843622,-0.1108558,43.4,1.700878358461843,18.469760022482863,5.136272459200213e-12,0.17412294207258677,329.33423317448216,8.500978318896191,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH720GB,ELITE Solar,Mono-c-Si,0,720.0,684.0,3.11,,,66.0,18.5,49.36,17.58,40.95,0.0084545,-0.1113068,43.4,1.708799322388147,18.510421919245108,5.2321151738859175e-12,0.17223579993133392,305.7366145824888,8.649925529260205,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH720GL,ELITE Solar,Mono-c-Si,0,720.0,684.0,3.11,,,66.0,18.5,49.36,17.58,40.95,0.0084545,-0.1113068,43.4,1.708799322388147,18.510421919245108,5.2321151738859175e-12,0.17223579993133392,305.7366145824888,8.649925529260205,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH725GB,ELITE Solar,Mono-c-Si,0,725.0,688.8,3.11,,,66.0,18.54,49.56,17.62,41.15,0.00847278,-0.11175780000000002,43.4,1.7162970692983017,18.550234757486184,5.294606861753847e-12,0.1703615387880485,308.60554752262436,8.736908020069531,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +ELITE Solar ET-N866TBH725GL,ELITE Solar,Mono-c-Si,0,725.0,688.8,3.11,,,66.0,18.54,49.56,17.62,41.15,0.00847278,-0.11175780000000002,43.4,1.7162970692983017,18.550234757486184,5.294606861753847e-12,0.1703615387880485,308.60554752262436,8.736908020069531,-0.2991,N,2025.7.3,6/23/2025,4.0,bootstrapping +EMMVEE Photovoltaic Power Private Limited E370M72-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,370.0,338.2,1.993,,,72.0,9.66,45.25,9.29,39.8,0.00841386,-0.132311,46.95,1.7345515086406553,9.660000196336274,4.365071444284212e-11,0.0009999900032804131,49200.88794549833,100.00000098612745,-0.3952,N,2025.7.3,6/23/2025,2.0,first_pass +EMMVEE Photovoltaic Power Private Limited E375M72,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,375.0,344.8,1.993,,,72.0,9.88,48.5,9.37,40.0,0.005187000000000001,-0.1326475,46.95,1.849934644954535,9.883434137837467,4.0411857028243415e-11,0.30459501230185615,876.3186011802613,11.120984503851995,-0.3716,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E375M72-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,375.0,342.9,1.993,,,72.0,9.88,45.5,9.37,40.0,0.00860548,-0.133042,46.95,1.8514338349533341,9.880000234317816,2.0974174926568838e-10,0.0009999900064990223,42164.9981534049,40.55634343225305,-0.3952,N,2025.7.3,6/23/2025,2.0,first_pass +EMMVEE Photovoltaic Power Private Limited E380M72,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,380.0,349.6,1.993,,,72.0,9.96,48.7,9.45,40.2,0.005229,-0.13319450000000002,46.95,1.8580079563728429,9.963135709170263,4.1012954712965234e-11,0.2991402073864644,950.1635701802481,11.179634659595942,-0.3716,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E380M72-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,380.0,347.6,1.993,,,72.0,9.96,45.7,9.45,40.2,0.008675160000000001,-0.1336268,46.95,1.7108887776471544,9.960000036081464,2.498607399501873e-11,0.0009999902976549524,275768.851595719,-0.6124667881963148,-0.3952,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E385M72,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,385.0,354.3,1.993,,,72.0,10.06,48.9,9.55,40.32,0.005281500000000001,-0.1337415,46.95,1.864079769706065,10.062733530881513,4.055698029400889e-11,0.3028825424946922,1114.6750104916018,10.986795815916846,-0.3716,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E385M72-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,385.0,352.3,1.993,,,72.0,10.06,45.9,9.55,40.32,0.008762260000000001,-0.13421160000000001,46.95,1.7459663477141467,10.060025130745213,3.8052277128205256e-11,0.0009999905373057451,400.3026893232489,2.8058064368439415,-0.3952,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E390M72,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,390.0,359.0,1.993,,,72.0,10.12,49.0,9.66,40.37,0.005313,-0.134015,46.95,1.8656801923661326,10.120004391377822,3.971181304460279e-11,0.30525442538004277,703490.6319435724,10.729726788643234,-0.3716,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E390M72-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,390.0,357.1,1.993,,,72.0,10.12,46.0,9.66,40.37,0.00881452,-0.134504,46.95,1.7718637483317823,10.120009416613087,5.351345016952143e-11,0.0009999906110032416,1074.6863249827531,5.6220332632612156,-0.3952,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E395M72,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,395.0,363.8,1.993,,,72.0,10.21,49.1,9.75,40.45,0.00536025,-0.13428850000000003,46.95,1.8698649498466968,10.21000298824107,4.0277917365829746e-11,0.29266224541937536,999999.8545467219,10.77717947881423,-0.3716,N,2025.7.3,6/23/2025,2.0,first_pass +EMMVEE Photovoltaic Power Private Limited E395M72-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,395.0,361.8,1.993,,,72.0,10.21,46.1,9.75,40.45,0.00889291,-0.1347964,46.95,1.779722023340602,10.210008162515772,5.727428182442775e-11,0.00099999069630875,1250.8282628973438,6.128251496477007,-0.3952,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E430HCM120-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,430.0,399.1,2.169,,,120.0,13.27,41.27,12.64,34.02,0.009036869999999999,-0.12050840000000002,45.22,1.5933315986828644,13.27017352636818,7.478558046043216e-11,0.19085081022604816,14594.885464022505,6.544706761243709,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E435HCM120-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,435.0,403.8,2.169,,,120.0,13.38,41.3,12.74,34.14,0.00911178,-0.12059599999999998,45.22,1.5961602563824004,13.38009290936833,7.74843310175173e-11,0.18088801060217835,26049.97178864691,6.779272864433575,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E440HCM120-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,440.0,408.6,2.169,,,120.0,13.55,41.44,12.87,34.21,0.00922755,-0.1210048,45.22,1.6023883595398598,13.552487511689261,7.929112133215048e-11,0.18318677275329548,997.857047795831,6.878556576702069,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E445HCM120-B,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,445.0,413.4,2.169,,,120.0,13.75,41.46,12.99,34.28,0.00936375,-0.1210632,45.22,1.6087754928935565,13.757931514975105,8.749043004303733e-11,0.17550931754633264,304.2613191749833,7.626959473393972,-0.3673,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E450HCM120-BT,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,450.0,423.4,2.1,,,120.0,13.53,42.2,12.87,34.99,0.00748209,-0.100014,45.97,1.48000288159616,13.535865344505826,5.5628569507851215e-12,0.19960022799179028,460.4317950763866,6.432406427756113,-0.2999,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E455HCM120-BT,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,455.0,428.2,2.1,,,120.0,13.6,42.36,12.92,35.24,0.007520800000000001,-0.10039319999999999,45.97,1.488816678508475,13.607148253733031,5.934559011690258e-12,0.18894877318614003,359.48686518184195,6.962479221756351,-0.2999,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E460HCM120-BT,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,460.0,433.0,2.1,,,120.0,13.67,42.52,12.97,35.49,0.007559510000000001,-0.1007724,45.97,1.497638081117058,13.67824488438368,6.327399029200815e-12,0.17837945382200157,295.75273932775445,7.489829254522373,-0.2999,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E465HCM120-BT,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,465.0,437.8,2.1,,,120.0,13.74,42.68,13.02,35.74,0.00759822,-0.1011516,45.97,1.5064669493402838,13.749159283910025,6.74234570490405e-12,0.16789126740349816,251.85659090793106,8.014463725996496,-0.2999,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E470HCM120-BT,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,470.0,442.7,2.1,,,120.0,13.81,42.82,13.09,35.91,0.00763693,-0.1014834,45.97,1.5122737694827058,13.81879431209501,6.888771841723548e-12,0.16301177603327113,255.98280908284232,8.159505660271341,-0.2999,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E530HCBG144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,530.0,494.1,2.56,,,144.0,13.56,49.2,12.9,41.1,0.00676644,-0.1337256,45.48,1.83007177206473,13.563229113941352,2.8491025108633317e-11,0.1881033721549936,789.9014055860463,5.982195298913466,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E530HCMW144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,530.0,492.2,2.56,,,144.0,13.56,49.2,12.9,41.1,0.00663084,-0.14169600000000002,45.24,1.8777915933433957,13.560004895894648,5.666438136594571e-11,0.17990332471159637,498287.7564392778,5.696286185052267,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E535HCBG144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,535.0,498.9,2.56,,,144.0,13.59,49.35,12.95,41.32,0.00678141,-0.1341333,45.48,1.836319560570363,13.591868761664653,2.8884582790967272e-11,0.18001087520294515,1309.0743211876834,6.074796102419515,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E535HCMW144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,535.0,496.9,2.56,,,144.0,13.59,49.35,12.95,41.32,0.0066455099999999994,-0.142128,45.24,1.888610269613991,13.590860641927662,6.087052159079921e-11,0.171118985359209,2702.061494578402,6.2952596766555295,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E540HCBG144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,540.0,503.7,2.56,,,144.0,13.62,49.5,13.0,41.54,0.0067963799999999994,-0.134541,45.48,1.8425587731503128,13.620625215007735,2.9277554566692815e-11,0.17198598479417804,3746.630358493561,6.1657328698490215,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E540HCMW144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,540.0,501.7,2.56,,,144.0,13.62,49.5,13.0,41.54,0.006660179999999999,-0.14256,45.24,1.8958739030280627,13.620081048254926,6.237111432819864e-11,0.16295532832052226,27384.369948128482,6.481318058420484,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E545HCBG144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,545.0,508.5,2.56,,,144.0,13.88,49.75,13.1,41.61,0.00692612,-0.1352205,45.48,1.8588211403363972,13.890096615150703,3.257009969866465e-11,0.1806466152271524,248.33818112031668,6.969884224877834,-0.3465,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E545HCMW144,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,545.0,506.5,2.56,,,144.0,13.88,49.75,13.1,41.61,0.00678732,-0.14328,45.24,1.9119871541125228,13.888653111142967,6.864528389434396e-11,0.17169737958719905,275.41073356012777,7.188829665237482,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E550HCBG144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,550.0,513.3,2.56,,,144.0,14.01,50.27,13.23,41.58,0.00861615,-0.12265880000000001,46.49,1.841904557493258,14.021871049113143,1.9407834534711737e-11,0.2255392799174432,266.177430117186,14.100606029135403,-0.3304,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E550HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,550.0,519.5,2.56,,,144.0,14.01,50.27,13.23,41.58,0.0061784100000000005,-0.1181345,45.77,1.7122740587910819,14.026483673715084,2.4501890559800117e-12,0.24748485178844845,210.345268723913,0.21297042762402468,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E555HCBG144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,555.0,518.1,2.56,,,144.0,14.07,50.47,13.29,41.77,0.00865305,-0.1231468,46.49,1.8495525103725392,14.081583941781084,1.958782362078291e-11,0.22335841135698234,271.29391035565396,14.145846417540604,-0.3304,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E555HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,555.0,524.3,2.56,,,144.0,14.07,50.47,13.29,41.77,0.006204870000000001,-0.1186045,45.77,1.7193691087293044,14.086160933924816,2.4731802293626736e-12,0.2453064193978299,213.56818447374468,0.2542686310935135,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E555HCMW144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,555.0,523.3,2.56,,,144.0,14.07,50.47,13.29,41.77,0.007457100000000001,-0.11825121000000001,46.09,1.7472832548691422,14.085122677573716,3.955704466773296e-12,0.2405498894496407,223.8053979269238,4.409881411224321,-0.2894,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E560HCBG144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,560.0,522.9,2.56,,,144.0,14.13,50.67,13.35,41.95,0.00868995,-0.1236348,46.49,1.8569826673728178,14.141326529549419,1.9705621125588304e-11,0.22205729906705549,277.0195094875737,14.161063117904268,-0.3304,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E560HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,560.0,529.2,2.56,,,144.0,14.13,50.67,13.35,41.95,0.00623133,-0.1190745,45.77,1.726271592874626,14.145879788293934,2.4881337511674673e-12,0.24399959566854748,217.11336616461128,0.268054272977643,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E560HCMW144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,560.0,528.1,2.56,,,144.0,14.13,50.67,13.35,41.95,0.007488900000000001,-0.11871981000000001,46.09,1.7542992524970007,14.144846458025905,3.9796207409803034e-12,0.23924424353452753,227.69883292883065,4.424217116234977,-0.2894,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E565HCBG144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,565.0,527.7,2.56,,,144.0,14.19,50.87,13.41,42.14,0.00872685,-0.12412279999999998,46.49,1.8646301227773563,14.201047593168157,1.9886159779922095e-11,0.219911934632158,282.464273105275,14.205639017488668,-0.3304,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E565HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,565.0,534.0,2.56,,,144.0,14.19,50.87,13.41,42.14,0.00625779,-0.11954449999999997,45.77,1.7333662320346375,14.205565352508293,2.5111990546992647e-12,0.24185663031856777,220.48621039015563,0.3087510361056797,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E565HCMW144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,565.0,532.9,2.56,,,144.0,14.19,50.87,13.41,42.14,0.0075207,-0.11918841,46.09,1.76151281085203,14.20453949510188,4.016451869154804e-12,0.23710069777269435,231.4013573394123,4.466327210977143,-0.2894,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E570HCBG144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,570.0,532.5,2.56,,,144.0,14.25,51.07,13.48,42.29,0.00876375,-0.12461080000000001,46.49,1.8707671044514311,14.260060862973276,1.9649002300677145e-11,0.22122737983915336,313.34192797695374,14.050129047589513,-0.3304,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E570HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,570.0,538.8,2.56,,,144.0,14.25,51.07,13.48,42.29,0.006284250000000001,-0.12001450000000001,45.77,1.7391249817007701,14.264512204527472,2.4802082582737596e-12,0.2431100679491136,238.71758545997662,0.16560972477512945,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E570HCMW144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,570.0,537.8,2.56,,,144.0,14.25,51.07,13.48,42.29,0.0075525,-0.11965701000000001,46.09,1.7673540469160594,14.26350056623485,3.9673081740390146e-12,0.23836734280513697,251.59942049775225,4.319008940641055,-0.2894,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E575HCBG144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,575.0,537.3,2.56,,,144.0,14.31,51.27,13.55,42.44,0.00880065,-0.1250988,46.49,1.8769086946921703,14.319059481580414,1.9417619113636733e-11,0.2225277255093502,351.496027343669,13.896422784837197,-0.3304,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E575HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,575.0,543.7,2.56,,,144.0,14.31,51.27,13.55,42.44,0.006310710000000001,-0.12048450000000001,45.77,1.7448880224033412,14.32344493793514,2.4499938788113514e-12,0.24434914195254753,260.07083383170004,0.024158048434850553,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E575HCMW144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,0,575.0,542.6,2.56,,,144.0,14.31,51.27,13.55,42.44,0.0075843,-0.12012561000000002,46.09,1.7731995692157554,14.322447414889865,3.919383041139936e-12,0.239619479666742,275.47525202342223,4.173413508407187,-0.2894,N,2025.7.3,6/23/2025,4.0,first_pass +EMMVEE Photovoltaic Power Private Limited E580HCBT144-T,EMMVEE Photovoltaic Power Private Limited,Mono-c-Si,1,580.0,548.5,2.56,,,144.0,14.37,51.47,13.62,42.59,0.00633717,-0.1209545,45.77,1.7506552835213507,14.382363766577598,2.420530447838898e-12,0.24557409880665693,285.4227136957169,-0.11563310674248435,-0.284,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Energy Inc EG-108L395W,Energate Energy Inc,Mono-c-Si,0,395.0,369.9,1.94,,,54.0,13.71,36.9,13.03,30.32,0.0075542100000000004,-0.112914,43.7,1.3901919454845586,13.712789311305112,4.057672810756181e-11,0.17929749260596675,881.2816158777111,-3.3641479466216184,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Energy Inc EG-108L400W,Energate Energy Inc,Mono-c-Si,0,400.0,374.7,1.94,,,54.0,13.78,36.98,13.15,30.42,0.00759278,-0.11315879999999999,43.7,1.3932808888272739,13.780002369865963,4.095885374924027e-11,0.17196284524657945,999993.3728430948,-3.339551890136537,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-108L405W,Energate Energy Inc,Mono-c-Si,0,405.0,379.5,1.94,,,54.0,13.85,37.06,13.27,30.52,0.007631350000000001,-0.11340360000000001,43.7,1.3995425280786216,13.8500173506153,4.378122415100114e-11,0.15815225238486358,126245.06625006764,-2.85656199569528,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-108L410W,Energate Energy Inc,Mono-c-Si,0,410.0,384.3,1.94,,,54.0,13.92,37.14,13.39,30.62,0.00766992,-0.1136484,43.7,1.4057758384631394,13.920002399372127,4.674792568248753e-11,0.1438046043844299,834174.8946760175,-2.379681738122871,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-108L415W,Energate Energy Inc,Mono-c-Si,0,415.0,389.1,1.94,,,54.0,14.01,37.31,13.48,30.79,0.007719510000000001,-0.11416860000000001,43.7,1.4129881286490693,14.010002357434763,4.7739309343769745e-11,0.14042026074374248,834392.6504611396,-2.2647717912631227,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-120L440W,Energate Energy Inc,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Energy Inc EG-120L445W,Energate Energy Inc,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-120L450W,Energate Energy Inc,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Energy Inc EG-120L455W,Energate Energy Inc,Mono-c-Si,0,455.0,426.6,2.14,,,60.0,13.93,41.33,13.36,34.06,0.0076754300000000004,-0.1264698,43.7,1.561482588686671,13.930004894121794,4.455061537197176e-11,0.18795642225008663,534996.2075622685,-2.764886288840815,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Energy Inc EG-120L460W,Energate Energy Inc,Mono-c-Si,0,460.0,431.4,2.14,,,60.0,14.01,41.48,13.45,34.2,0.007719510000000001,-0.1269288,43.7,1.5684678629551188,14.01028556728525,4.580062315481237e-11,0.1859467515856264,9122.598678731394,-2.5911118818842573,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Energy Inc EG-144L530W,Energate Energy Inc,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-144L535W,Energate Energy Inc,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-144L540W,Energate Energy Inc,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-144L545W,Energate Energy Inc,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.52,13.36,40.8,0.00768094,-0.1515312,43.7,1.870684691617212,13.9400028925779,4.4442188120097235e-11,0.20748896460190644,999993.9298367809,-2.7897108880311374,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Energy Inc EG-144L550W,Energate Energy Inc,Mono-c-Si,0,550.0,515.8,2.56,,,72.0,14.03,49.62,13.45,40.9,0.007730530000000001,-0.15183719999999998,43.7,1.875059829127246,14.030002864676204,4.510802130948321e-11,0.20416909236898073,999992.6444283266,-2.7233274202719366,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-108L395W,Energate Enerji retim San A ,Mono-c-Si,0,395.0,369.9,1.94,,,54.0,13.71,36.9,13.03,30.32,0.0075542100000000004,-0.112914,43.7,1.3901919454845586,13.712789311305112,4.057672810756181e-11,0.17929749260596675,881.2816158777111,-3.3641479466216184,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Enerji retim San A EG-108L400W,Energate Enerji retim San A ,Mono-c-Si,0,400.0,374.7,1.94,,,54.0,13.78,36.98,13.15,30.42,0.00759278,-0.11315879999999999,43.7,1.3932808888272739,13.780002369865963,4.095885374924027e-11,0.17196284524657945,999993.3728430948,-3.339551890136537,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-108L405W,Energate Enerji retim San A ,Mono-c-Si,0,405.0,379.5,1.94,,,54.0,13.85,37.06,13.27,30.52,0.007631350000000001,-0.11340360000000001,43.7,1.3995425280786216,13.8500173506153,4.378122415100114e-11,0.15815225238486358,126245.06625006764,-2.85656199569528,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-108L410W,Energate Enerji retim San A ,Mono-c-Si,0,410.0,384.3,1.94,,,54.0,13.92,37.14,13.39,30.62,0.00766992,-0.1136484,43.7,1.4057758384631394,13.920002399372127,4.674792568248753e-11,0.1438046043844299,834174.8946760175,-2.379681738122871,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-108L415W,Energate Enerji retim San A ,Mono-c-Si,0,415.0,389.1,1.94,,,54.0,14.01,37.31,13.48,30.79,0.007719510000000001,-0.11416860000000001,43.7,1.4129881286490693,14.010002357434763,4.7739309343769745e-11,0.14042026074374248,834392.6504611396,-2.2647717912631227,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-120L440W,Energate Enerji retim San A ,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Enerji retim San A EG-120L445W,Energate Enerji retim San A ,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-120L450W,Energate Enerji retim San A ,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Enerji retim San A EG-120L455W,Energate Enerji retim San A ,Mono-c-Si,0,455.0,426.6,2.14,,,60.0,13.93,41.33,13.36,34.06,0.0076754300000000004,-0.1264698,43.7,1.561482588686671,13.930004894121794,4.455061537197176e-11,0.18795642225008663,534996.2075622685,-2.764886288840815,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Enerji retim San A EG-120L460W,Energate Enerji retim San A ,Mono-c-Si,0,460.0,431.4,2.14,,,60.0,14.01,41.48,13.45,34.2,0.007719510000000001,-0.1269288,43.7,1.5684678629551188,14.01028556728525,4.580062315481237e-11,0.1859467515856264,9122.598678731394,-2.5911118818842573,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Energate Enerji retim San A EG-144L530W,Energate Enerji retim San A ,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-144L535W,Energate Enerji retim San A ,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-144L540W,Energate Enerji retim San A ,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-144L545W,Energate Enerji retim San A ,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.52,13.36,40.8,0.00768094,-0.1515312,43.7,1.870684691617212,13.9400028925779,4.4442188120097235e-11,0.20748896460190644,999993.9298367809,-2.7897108880311374,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energate Enerji retim San A EG-144L550W,Energate Enerji retim San A ,Mono-c-Si,0,550.0,515.8,2.56,,,72.0,14.03,49.62,13.45,40.9,0.007730530000000001,-0.15183719999999998,43.7,1.875059829127246,14.030002864676204,4.510802130948321e-11,0.20416909236898073,999992.6444283266,-2.7233274202719366,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Energy America LLC EA-ZLK7-SHDB108-390/M,Energy America LLC,Mono-c-Si,1,390.0,362.1,1.94,,,54.0,13.54,36.7,12.79,30.5,0.0075823999999999996,-0.09798900000000002,46.1,1.3811033513120292,13.549310615901863,3.855335682339475e-11,0.15166678429914646,220.56202406792025,10.537983816822907,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB108-395/M,Energy America LLC,Mono-c-Si,1,395.0,366.8,1.94,,,54.0,13.62,36.9,12.87,30.7,0.0076272,-0.098523,46.1,1.3891798503683634,13.628937187946065,3.920298518649281e-11,0.14859355955018455,226.4520158605057,10.6338783710813,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB108-400/M,Energy America LLC,Mono-c-Si,1,400.0,371.6,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007671999999999999,-0.099057,46.1,1.3972554244129742,13.708573768327355,3.9856506905113645e-11,0.14555899163443753,232.58830173746986,10.728581325313126,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB108-405/M,Energy America LLC,Mono-c-Si,1,405.0,376.4,1.94,,,54.0,13.78,37.3,13.03,31.1,0.0077168,-0.099591,46.1,1.4053300916186309,13.788220164811934,4.0513883942915417e-11,0.14256235454485405,238.98660429173054,10.822114839467288,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB108-410/M,Energy America LLC,Mono-c-Si,1,410.0,381.2,1.94,,,54.0,13.86,37.5,13.1,31.3,0.0077616000000000004,-0.100125,46.1,1.4139285285133854,13.868541943106624,4.1545145248748684e-11,0.13954682104728888,226.42611210108373,10.998238485631964,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB108-415/M,Energy America LLC,Mono-c-Si,1,415.0,386.0,1.94,,,54.0,13.94,37.7,13.18,31.5,0.0078064,-0.10065900000000003,46.1,1.3831989551967714,13.9496010036313,2.0039872941207657e-11,0.14314818734892837,207.84136968764992,4.574960867160664,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB144-530/M,Energy America LLC,Mono-c-Si,1,530.0,495.7,2.58,,,72.0,13.65,49.4,12.91,41.1,0.008599500000000001,-0.129922,45.5,1.8254975272395844,13.659070548349053,2.3866449065126317e-11,0.20426294470826037,307.38926847380367,7.783672063677799,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB144-535/M,Energy America LLC,Mono-c-Si,1,535.0,500.5,2.58,,,72.0,13.71,49.6,12.96,41.3,0.0086373,-0.130448,45.5,1.7959210782365007,13.720649581657963,1.3710647855705824e-11,0.2077253226352284,267.4202873910387,2.9889420551408024,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB144-540/M,Energy America LLC,Mono-c-Si,1,540.0,505.3,2.58,,,72.0,13.77,49.8,13.02,41.5,0.0086751,-0.130974,45.5,1.84202055510055,13.779240001659677,2.468861260046973e-11,0.19817211104870272,295.3278683524019,8.005943858995565,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB144-545/M,Energy America LLC,Mono-c-Si,1,545.0,510.1,2.58,,,72.0,13.83,50.0,13.07,41.7,0.0087129,-0.1315,45.5,1.8506210554220281,13.839664385758248,2.5218567517668896e-11,0.19513365240535965,279.2415890394617,8.156950951504486,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB144-550/M,Energy America LLC,Mono-c-Si,1,550.0,514.9,2.58,,,72.0,13.89,50.2,13.13,41.9,0.0087507,-0.132026,45.5,1.85854337445892,13.899385936326567,2.5525693780204705e-11,0.19218419087066824,284.4083271386615,8.224652133782982,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Energy America LLC EA-ZLK7-SHDB144-555/M,Energy America LLC,Mono-c-Si,1,555.0,519.7,2.58,,,72.0,13.95,50.4,13.19,42.1,0.0087885,-0.132552,45.5,1.8664650283324231,13.959112917593322,2.5834126706629213e-11,0.18926203457876015,289.72119830783936,8.29173219126789,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Enp Sonne Solar Technikk ENP-M165MO,Enp Sonne Solar Technikk,Mono-c-Si,0,165.0,147.3,1.279029,1.581,0.809,72.0,5.08,43.6,4.66,35.4,0.002395322519803848,-0.16534910714285694,44.4,1.9525339023534043,5.091876267266119,9.834793339242188e-10,0.5422880399452672,231.96042058553917,9.345523468096253,-0.5087314662273477,N,2025.7.3,6/23/2025,4.0,first_pass +Enp Sonne Solar Technikk ENP-M170MO,Enp Sonne Solar Technikk,Mono-c-Si,0,170.0,151.8,1.279029,1.581,0.809,72.0,5.15,44.2,4.78,35.0,0.0024283289324783103,-0.16762455357142841,44.4,1.9359875475708552,5.159004221873056,6.148299609987226e-10,0.7681385912084804,439.3400656776548,5.085575838161973,-0.5087314662273477,N,2025.7.3,6/23/2025,4.0,first_pass +Enphase Energy Inc XACM-IQ7-LR6-60PB-300M,Enphase Energy Inc,Mono-c-Si,0,300.0,273.2,1.58,,,60.0,9.81,40.1,9.15,32.8,0.0035315999999999998,-0.113884,48.2,1.5473471012411215,9.82715261716305,5.327209344316843e-11,0.2840947467854717,162.48071029275835,9.735227111874273,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +Enphase Energy Inc XACM-IQ7-LR6-60PB-305M,Enphase Energy Inc,Mono-c-Si,0,305.0,278.9,1.58,,,60.0,9.94,40.2,9.24,33.0,0.0041748,-0.11215800000000002,48.75,1.525135194196247,9.96064124002585,3.447441470510852e-11,0.2734669653900962,131.69081193842513,7.6921850882543605,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP125M/72-205W,Eoplly New Energy Technology,Mono-c-Si,0,205.0,182.4,1.2766400000000002,1.58,0.808,72.0,5.92,46.21,5.52,37.47,0.003552,-0.166356,46.8,2.0280048926211136,5.92664601600622,7.405770598523738e-10,0.5160084910577015,459.63949815505947,11.008134088055222,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-225S AC,Eoplly New Energy Technology,Multi-c-Si,0,225.0,200.7,1.6341359999999998,1.644,0.994,60.0,8.48,36.13,7.65,29.62,0.005088,-0.12645499999999998,46.0,1.6091168261791204,8.507298370540015,1.4187958828749878e-09,0.23076801967693975,71.68607538118823,17.066913997748188,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-230S AC,Eoplly New Energy Technology,Mono-c-Si,0,230.0,205.5,1.6183439999999998,1.638,0.988,60.0,8.48,36.55,7.87,29.24,0.005088,-0.12792499999999998,46.3,1.5628547283670247,8.495820986178284,5.787626452022749e-10,0.35281314652158957,189.10680607027598,8.74014793175775,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-230S AC,Eoplly New Energy Technology,Mono-c-Si,0,230.0,205.5,1.6183439999999998,1.638,0.988,60.0,8.48,36.55,7.87,29.24,0.005088,-0.12792499999999998,46.3,1.5628547283670247,8.495820986178284,5.787626452022749e-10,0.35281314652158957,189.10680607027598,8.74014793175775,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-230S AC,Eoplly New Energy Technology,Multi-c-Si,0,230.0,205.2,1.6341359999999998,1.644,0.994,60.0,8.56,36.42,7.71,30.05,0.005136000000000001,-0.12747,46.0,1.6300857610170112,8.584825221063255,1.5959559505639026e-09,0.20025852970814262,69.05127713283534,18.11446064039177,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-235S AC,Eoplly New Energy Technology,Mono-c-Si,0,235.0,210.1,1.6183439999999998,1.638,0.988,60.0,8.56,36.72,7.94,29.6,0.005136000000000001,-0.12852,46.3,1.5777243553393434,8.575374494635081,6.528655984374261e-10,0.31755714381882977,176.8051403895525,9.728502763672768,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-235S AC,Eoplly New Energy Technology,Mono-c-Si,0,235.0,210.1,1.6183439999999998,1.638,0.988,60.0,8.56,36.72,7.94,29.6,0.005136000000000001,-0.12852,46.3,1.5777243553393434,8.575374494635081,6.528655984374261e-10,0.31755714381882977,176.8051403895525,9.728502763672768,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-235S AC,Eoplly New Energy Technology,Multi-c-Si,0,235.0,209.8,1.6341359999999998,1.644,0.994,60.0,8.64,36.72,7.79,30.29,0.005184,-0.12852,46.0,1.6422321117444043,8.664731439156377,1.585054733512116e-09,0.20147892591900474,70.38725567575884,17.955170586020216,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-240S AC,Eoplly New Energy Technology,Mono-c-Si,0,240.0,215.3,1.6183439999999998,1.638,0.988,60.0,8.68,36.9,8.01,30.01,0.00434,-0.12546000000000002,46.2,1.5672210779123947,8.698910193111248,5.007749060899925e-10,0.2829789202650214,129.89064998991142,10.599472043178078,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-240 AC,Eoplly New Energy Technology,Mono-c-Si,0,240.0,214.7,1.6183439999999998,1.638,0.988,60.0,8.68,36.9,8.01,30.01,0.005208,-0.12915,46.3,1.59848760568717,8.697715504059634,7.945358207875687e-10,0.2749123375845128,134.69780326918863,11.38611348238741,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-240S AC,Eoplly New Energy Technology,Mono-c-Si,0,240.0,214.7,1.6183439999999998,1.638,0.988,60.0,8.68,36.9,8.01,30.01,0.005208,-0.12915,46.3,1.59848760568717,8.697715504059634,7.945358207875687e-10,0.2749123375845128,134.69780326918863,11.38611348238741,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-240 AC,Eoplly New Energy Technology,Multi-c-Si,0,240.0,214.4,1.6341359999999998,1.644,0.994,60.0,8.68,37.02,7.9,30.54,0.005208,-0.12957,46.0,1.6463394518317598,8.700390985593252,1.4193890815635904e-09,0.20432702292262436,86.97759009401368,16.821258349879596,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-240S AC,Eoplly New Energy Technology,Multi-c-Si,0,240.0,214.4,1.6341359999999998,1.644,0.994,60.0,8.68,37.02,7.9,30.54,0.005208,-0.12957,46.0,1.6463394518317598,8.700390985593252,1.4193890815635904e-09,0.20432702292262436,86.97759009401368,16.821258349879596,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-240W,Eoplly New Energy Technology,Multi-c-Si,0,240.0,214.4,1.6341359999999998,1.644,0.994,60.0,8.68,37.02,7.9,30.54,0.005208,-0.12957,46.0,1.6463394518317598,8.700390985593252,1.4193890815635904e-09,0.20432702292262436,86.97759009401368,16.821258349879596,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-245S AC,Eoplly New Energy Technology,Mono-c-Si,0,245.0,219.9,1.6183439999999998,1.638,0.988,60.0,8.78,37.08,8.08,30.42,0.00439,-0.126072,46.2,1.5854834083822302,8.79853503953925,5.905067038845546e-10,0.24212386551095127,114.69345537792977,11.993502837760603,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-245 AC,Eoplly New Energy Technology,Mono-c-Si,0,245.0,219.3,1.6183439999999998,1.638,0.988,60.0,8.78,37.08,8.08,30.42,0.005267999999999999,-0.12977999999999998,46.3,1.6172653547615852,8.797353849998439,9.360033514060688e-10,0.23393617103890527,118.35759013197595,12.786608342337983,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-245S AC,Eoplly New Energy Technology,Mono-c-Si,0,245.0,219.3,1.6183439999999998,1.638,0.988,60.0,8.78,37.08,8.08,30.42,0.005267999999999999,-0.12977999999999998,46.3,1.6172653547615852,8.797353849998439,9.360033514060688e-10,0.23393617103890527,118.35759013197595,12.786608342337983,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-245W,Eoplly New Energy Technology,Mono-c-Si,0,245.0,219.3,1.6183439999999998,1.638,0.988,60.0,8.78,37.08,8.08,30.42,0.005267999999999999,-0.12977999999999998,46.3,1.6172653547615852,8.797353849998439,9.360033514060688e-10,0.23393617103890527,118.35759013197595,12.786608342337983,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-245 AC,Eoplly New Energy Technology,Multi-c-Si,0,245.0,220.0,1.6341359999999998,1.644,0.994,60.0,8.75,37.38,7.96,31.02,0.004375,-0.12335400000000002,47.1,1.5850074374400929,8.771531793100833,4.758096627125038e-10,0.19938275807232736,81.0243346805834,13.499822636054086,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-245S AC,Eoplly New Energy Technology,Multi-c-Si,0,245.0,220.0,1.6341359999999998,1.644,0.994,60.0,8.75,37.38,7.96,31.02,0.004375,-0.12335400000000002,47.1,1.5850074374400929,8.771531793100833,4.758096627125038e-10,0.19938275807232736,81.0243346805834,13.499822636054086,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-245W,Eoplly New Energy Technology,Multi-c-Si,0,245.0,220.0,1.6341359999999998,1.644,0.994,60.0,8.75,37.38,7.96,31.02,0.004375,-0.12335400000000002,47.1,1.5850074374400929,8.771531793100833,4.758096627125038e-10,0.19938275807232736,81.0243346805834,13.499822636054086,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-250 AC,Eoplly New Energy Technology,Mono-c-Si,0,250.0,224.5,1.6183439999999998,1.638,0.988,60.0,8.91,37.26,8.15,30.84,0.004455,-0.126684,46.2,1.6072668694819474,8.929008584115856,7.295027757537952e-10,0.19906615960737153,93.30940213317525,13.817179769950979,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-250S AC,Eoplly New Energy Technology,Mono-c-Si,0,250.0,224.5,1.6183439999999998,1.638,0.988,60.0,8.91,37.26,8.15,30.84,0.004455,-0.126684,46.2,1.6072668694819474,8.929008584115856,7.295027757537952e-10,0.19906615960737153,93.30940213317525,13.817179769950979,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156MB/60-250S AC,Eoplly New Energy Technology,Mono-c-Si,0,250.0,223.9,1.6183439999999998,1.638,0.988,60.0,8.91,37.26,8.15,30.84,0.005346,-0.13041,46.3,1.6396678233928623,8.92776184930214,1.1545546482511087e-09,0.19072411336475315,95.67427478599807,14.616030382208864,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-250S AC,Eoplly New Energy Technology,Multi-c-Si,0,250.0,224.6,1.6341359999999998,1.644,0.994,60.0,8.79,37.56,8.0,31.32,0.004395,-0.12394800000000002,47.1,1.5967886017718296,8.8091138003818,5.082083822700103e-10,0.17731733670496033,81.54419465702571,14.064474884724218,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-255 AC,Eoplly New Energy Technology,Mono-c-Si,0,255.0,229.2,1.6183439999999998,1.638,0.988,60.0,8.98,37.56,8.22,31.2,0.00449,-0.127704,46.2,1.6230038490227432,8.99736379902532,7.65566273658486e-10,0.18319300509615666,94.74155223870872,14.189465802684094,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-255S AC,Eoplly New Energy Technology,Mono-c-Si,0,255.0,229.2,1.6183439999999998,1.638,0.988,60.0,8.98,37.56,8.22,31.2,0.00449,-0.127704,46.2,1.6230038490227432,8.99736379902532,7.65566273658486e-10,0.18319300509615666,94.74155223870872,14.189465802684094,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-255S AC,Eoplly New Energy Technology,Multi-c-Si,0,255.0,229.2,1.6341359999999998,1.644,0.994,60.0,8.9,37.68,8.1,31.56,0.004450000000000001,-0.12434400000000001,47.1,1.6061399487997643,8.917175271058888,5.473516647123505e-10,0.15530300747396222,80.47598328341384,14.63782246077877,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-260 AC,Eoplly New Energy Technology,Mono-c-Si,0,260.0,233.8,1.6183439999999998,1.638,0.988,60.0,9.12,37.74,8.3,31.62,0.00456,-0.128316,46.2,1.644881915005607,9.13602355996863,9.406490651442718e-10,0.1411725720623145,80.35005643719838,15.992217886421361,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156M/60-260S AC,Eoplly New Energy Technology,Mono-c-Si,0,260.0,233.8,1.6183439999999998,1.638,0.988,60.0,9.12,37.74,8.3,31.62,0.00456,-0.128316,46.2,1.644881915005607,9.13602355996863,9.406490651442718e-10,0.1411725720623145,80.35005643719838,15.992217886421361,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Eoplly New Energy Technology EP156P/60-260S AC,Eoplly New Energy Technology,Multi-c-Si,0,260.0,233.8,1.6341359999999998,1.644,0.994,60.0,9.01,37.8,8.2,31.8,0.004505,-0.12474,47.1,1.6154829207522763,9.025177269764614,5.889310861539999e-10,0.13383832788135674,79.45324849773264,15.206464455046266,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Ergosun Holdings LLC Ergosun 175W Black,Ergosun Holdings LLC,Mono-c-Si,0,17.5,16.5,0.139,,,10.0,1.85,12.8,1.45,10.0,0.0009620000000000001,-0.044416,40.0,0.5273314989853928,1.9018719934864632,4.204171805893047e-11,0.818616473846162,29.195725771995274,0.8817151029364252,-0.353,Y,2025.7.3,6/23/2025,4.0,first_pass +Ergosun Holdings LLC Ergosun 55W,Ergosun Holdings LLC,Mono-c-Si,0,55.0,52.2,0.28,,,24.0,5.3,14.5,4.83,12.0,0.00265,-0.050749999999999997,40.0,0.5584011716895958,5.317198243899143,2.653016518509395e-11,0.1605577534330589,49.47924351500682,-11.723208482119428,-0.35,Y,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H54B-390,ES Foundry Corp,Mono-c-Si,1,390.0,365.0,1.947,,,18.0,13.61,36.85,12.73,30.64,0.0048996,-0.09319365,45.0,1.332839452129544,13.631426916366662,1.3049078514541173e-11,0.16011387943802222,101.7015173066174,7.192614207900089,-0.3328,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H54B-395,ES Foundry Corp,Mono-c-Si,1,395.0,369.8,1.947,,,18.0,13.7,36.98,12.81,30.84,0.004931999999999999,-0.09352242,45.0,1.3397445502148402,13.720916706405598,1.3737191897893297e-11,0.1513794197209224,99.15031629852726,7.586492683275951,-0.3328,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H54B-400,ES Foundry Corp,Mono-c-Si,1,400.0,374.5,1.947,,,18.0,13.79,37.07,12.9,31.01,0.004964399999999999,-0.09375003000000001,45.0,1.3447673234342805,13.809628890682543,1.4340259417518854e-11,0.1423478184901,100.00445028738302,7.904605876248728,-0.3328,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H54B-405,ES Foundry Corp,Mono-c-Si,1,405.0,379.4,1.947,,,18.0,13.87,37.23,12.98,31.21,0.004993199999999999,-0.09415467,45.0,1.3517415226174079,13.888696066406487,1.4775728552382817e-11,0.13632506953457793,101.13510931003889,8.11544135529177,-0.3328,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H54B-410,ES Foundry Corp,Mono-c-Si,1,410.0,384.2,1.947,,,18.0,13.95,37.32,13.04,31.45,0.005021999999999999,-0.09438228000000001,45.0,1.3593185977272344,13.967870390782654,1.6187403876170825e-11,0.1213314953450247,94.71389769329228,8.876260087190028,-0.3328,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H54B-415,ES Foundry Corp,Mono-c-Si,1,415.0,389.0,1.947,,,18.0,14.02,37.45,13.13,31.61,0.005047199999999999,-0.09471105000000002,45.0,1.3638909918372497,14.036018871407917,1.6248849975811575e-11,0.11692007756011888,102.3305231741704,8.857475287026901,-0.3328,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-420,ES Foundry Corp,Mono-c-Si,1,420.0,399.3,1.947,,,18.0,13.56,38.4,12.93,32.49,0.0049494,-0.0880128,43.5,1.3036267790268115,13.564781262626951,2.1699805250165e-12,0.13365499212687487,379.0550815603191,2.088998740863505,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-425,ES Foundry Corp,Mono-c-Si,1,425.0,404.1,1.947,,,18.0,13.64,38.59,13.01,32.67,0.0049786000000000006,-0.08844828,43.5,1.3102634897117953,13.644560670161834,2.1925692353160297e-12,0.13187374196733276,394.40647536883466,2.1257668164096604,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-430,ES Foundry Corp,Mono-c-Si,1,430.0,409.0,1.947,,,18.0,13.72,38.78,13.09,32.85,0.005007800000000001,-0.08888376,43.5,1.3169002258662674,13.724344938510708,2.2152170617212234e-12,0.1301143710708537,410.8617809482604,2.1621761445045005,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-435,ES Foundry Corp,Mono-c-Si,1,435.0,413.9,1.947,,,18.0,13.8,38.97,13.17,33.03,0.005037,-0.08931924,43.5,1.3235369897622284,13.804133981255006,2.2379235464503396e-12,0.12837647835918461,428.5446149189155,2.1982325339356397,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-440,ES Foundry Corp,Mono-c-Si,1,440.0,418.7,1.947,,,18.0,13.88,39.16,13.25,33.21,0.0050662,-0.08975471999999998,43.5,1.3301737808134224,13.883927715338917,2.2606880948373815e-12,0.1266596730371964,447.59767807562065,2.233941011288305,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-445,ES Foundry Corp,Mono-c-Si,1,445.0,423.6,1.947,,,18.0,13.96,39.35,13.33,33.39,0.0050954,-0.0901902,43.5,1.3368106009318756,13.963726064780394,2.283510229792079e-12,0.12496357332127461,468.1861071974657,2.2693071226230423,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DN8-H54B-450,ES Foundry Corp,Mono-c-Si,1,450.0,428.4,1.947,,,18.0,14.04,39.54,13.4,33.57,0.0051246,-0.09062567999999999,43.5,1.343888917249039,14.044080363787586,2.326781057443857e-12,0.12323571818181649,424.0380706358603,2.3827752659739634,-0.2845,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-520W,ES Foundry Corp,Mono-c-Si,1,520.0,484.4,2.49,,,72.0,13.57,48.9,12.67,41.1,0.005563700000000001,-0.126651,47.3,1.770820544509313,13.589549815081853,1.3408409608204107e-11,0.17469979939926994,121.26336102009925,4.855290525008618,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72-525,ES Foundry Corp,Mono-c-Si,1,525.0,492.2,2.56,,,72.0,13.65,49.15,12.76,41.15,0.0050778,-0.12321904999999998,45.0,1.7736286661836582,13.670155817047574,1.2258884887895411e-11,0.18937654094257547,128.25031034409346,7.555271046541025,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-525W,ES Foundry Corp,Mono-c-Si,1,525.0,489.2,2.49,,,72.0,13.65,49.1,12.75,41.2,0.005596500000000001,-0.127169,47.3,1.7762287457161696,13.669948043888212,1.311663350768456e-11,0.18054931513791275,123.54585602208182,4.615156773236736,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72-530,ES Foundry Corp,Mono-c-Si,1,530.0,497.0,2.56,,,72.0,13.72,49.3,12.83,41.31,0.00510384,-0.12359509999999999,45.0,1.7794725341168305,13.739666846315416,1.2408959685276354e-11,0.1859468217231389,129.72036085640013,7.615742955284783,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-530W,ES Foundry Corp,Mono-c-Si,1,530.0,494.0,2.49,,,72.0,13.71,49.2,12.82,41.4,0.0056211,-0.127428,47.3,1.7814054821036016,13.728159191953077,1.351075518749968e-11,0.16986967961912577,128.249831725347,4.8264590706650825,-0.323,N,2025.7.3,6/23/2025,2.0,first_pass +ES Foundry Corp ES-DP8-H72-535,ES Foundry Corp,Mono-c-Si,1,535.0,501.8,2.56,,,72.0,13.79,49.45,12.9,41.47,0.005129879999999999,-0.12397115,45.0,1.7853168313285308,13.809185962360637,1.2560030083402717e-11,0.18255450213755844,131.21190086294686,7.6758975896377155,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-535W,ES Foundry Corp,Mono-c-Si,1,535.0,498.7,2.49,,,72.0,13.78,49.4,12.9,41.5,0.005649800000000001,-0.127946,47.3,1.7861933911568764,13.7979304523305,1.3093497300705397e-11,0.17588141556511294,135.16925655051458,4.510213100497899,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72-540,ES Foundry Corp,Mono-c-Si,1,540.0,506.6,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00515592,-0.1243472,45.0,1.7913749419952865,13.878631640862583,1.275381703340829e-11,0.17831664131511923,132.64900678327393,7.764565881878118,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-540W,ES Foundry Corp,Mono-c-Si,1,540.0,497.4,2.51,,,72.0,13.85,49.5,12.97,41.7,0.0062325,-0.13167,48.7,1.867820472846247,13.864330644921644,4.185710779633652e-11,0.15201024154828538,146.9118710139717,11.68305587544871,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72-545,ES Foundry Corp,Mono-c-Si,1,545.0,511.4,2.56,,,72.0,13.93,49.75,13.04,41.8,0.00518196,-0.12472325,45.0,1.7972198564745114,13.948167547298508,1.2907187692337012e-11,0.17500219888025334,134.1832551934938,7.823976521268899,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +ES Foundry Corp ES-DP8-H72L-545W,ES Foundry Corp,Mono-c-Si,1,545.0,502.1,2.51,,,72.0,13.92,49.7,13.04,41.8,0.006264,-0.13220200000000001,48.7,1.8734656181507137,13.934658261815782,4.0974859291245404e-11,0.1579498903351004,149.99476174422543,11.443265624731115,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +ES Foundry Corp ES-DP8-H72-550,ES Foundry Corp,Mono-c-Si,1,550.0,516.2,2.56,,,72.0,14.0,49.9,13.11,41.96,0.005208,-0.1250993,45.0,1.8030651551468442,14.01771119172977,1.3061546360178991e-11,0.17172332353726255,135.7405288379733,7.883072896764899,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-550W,ES Foundry Corp,Mono-c-Si,1,550.0,506.9,2.51,,,72.0,13.99,49.8,13.12,42.0,0.0062955,-0.132468,48.7,1.878868889033862,14.00314032992415,4.218569811811158e-11,0.14746252152866982,156.9976325806495,11.656854595020873,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72-555,ES Foundry Corp,Mono-c-Si,1,555.0,521.0,2.56,,,72.0,14.07,50.05,13.18,42.12,0.005234040000000001,-0.12547534999999999,45.0,1.808910896049655,14.087262507754419,1.321690426648643e-11,0.1684794359813552,137.32104876677786,7.941866847362889,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +ES Foundry Corp ES-DP8-H72L-555W,ES Foundry Corp,Mono-c-Si,1,555.0,511.7,2.51,,,72.0,14.05,50.0,13.19,42.1,0.0063225,-0.133,48.7,1.8838525199251592,14.062915769510028,4.0923025364492905e-11,0.15356311624018076,167.04864532765063,11.339033826536376,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72-560,ES Foundry Corp,Mono-c-Si,1,560.0,525.8,2.56,,,72.0,14.14,50.2,13.25,42.28,0.0052600799999999994,-0.1258514,45.0,1.814757017831459,14.156821352644402,1.337325007877486e-11,0.16526998901559506,138.9256678079103,8.000351976553834,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +ES Foundry Corp ES-DP8-H72L-560W,ES Foundry Corp,Mono-c-Si,1,560.0,516.4,2.51,,,72.0,14.1,50.1,13.26,42.3,0.006344999999999999,-0.133266,48.7,1.8886324887646257,14.111053365306429,4.173192331795132e-11,0.1435231150312044,183.0823356401234,11.476603746994694,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +ES Foundry Corp ES-DP8-H72-565,ES Foundry Corp,Mono-c-Si,1,565.0,530.7,2.56,,,72.0,14.21,50.33,13.32,42.42,0.00528612,-0.12617731,45.0,1.8198136122007096,14.226411780611192,1.35169598595264e-11,0.1622997682365516,140.52586773642847,8.0496472726885,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +ES Foundry Corp ES-DP8-H72L-565W,ES Foundry Corp,Mono-c-Si,1,565.0,521.2,2.51,,,72.0,14.16,50.3,13.33,42.4,0.006372,-0.133798,48.7,1.8936358579839674,14.170766976102264,4.0501362026051465e-11,0.14957310723821615,196.70845198236555,11.163770095544661,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Exeltech AM24-1-B-6-0-00,Exeltech,Multi-c-Si,0,240.0,211.9,1.69974,1.596,1.065,96.0,5.28,59.5,4.95,48.6,0.0021436800000000002,-0.21348599999999998,47.3,2.580240392128726,5.283722962747168,5.047035251471755e-10,0.6760789718829668,958.832698725451,9.181395977435525,-0.4929,N,2025.7.3,6/23/2025,4.0,first_pass +Exiom Solution S A EX405-108BMH,Exiom Solution S A,Mono-c-Si,1,405.0,377.6,1.94,,,54.0,13.78,37.4,12.92,31.4,0.004823000000000001,-0.098362,45.6,1.3529230678196467,13.796774455189569,1.3287020996419248e-11,0.134607769391984,110.57855802636044,3.1104551863979575,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Exiom Solution S A EX410-108BMH,Exiom Solution S A,Mono-c-Si,1,410.0,382.4,1.94,,,54.0,13.86,37.5,13.0,31.6,0.004851,-0.098625,45.6,1.384411198136513,13.874362508727737,2.333677582538586e-11,0.11955659741500682,115.37360769274188,7.873924430930118,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Exiom Solution S A EX545-144BMH-DG,Exiom Solution S A,Mono-c-Si,1,545.0,509.1,2.58,,,72.0,13.92,49.8,13.04,41.8,0.005428799999999999,-0.128982,46.0,1.8124010418332455,13.937371573870776,1.584164443545911e-11,0.17648789344031685,141.42135143418852,6.077480042248692,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Exiom Solution S A EX545-144M-BMH,Exiom Solution S A,Mono-c-Si,1,545.0,510.6,2.58,,,72.0,13.92,49.8,13.04,41.8,0.005985599999999999,-0.126492,45.8,1.7971906160844289,13.937906863164491,1.2550019510988275e-11,0.17911966154823528,139.23966867305745,6.094405789230833,-0.321,N,2025.7.3,6/23/2025,2.0,first_pass +Exiom Solution S A EX550-144MH,Exiom Solution S A,Mono-c-Si,0,545.0,504.2,2.54,,,72.0,13.92,49.8,13.04,41.8,0.0077951999999999995,-0.145914,45.8,1.9672331437724624,13.93243182622643,1.3824236721442544e-10,0.15014966230535284,168.12359732126998,11.378854504746341,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Exiom Solution S A EX545-144MH,Exiom Solution S A,Mono-c-Si,0,550.0,508.9,2.54,,,72.0,13.99,49.9,13.1,42.0,0.0078344,-0.146207,45.8,1.9745707407210733,14.00202616383209,1.4499206310360485e-10,0.13935487148015643,162.11110367559832,11.76573238801514,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Exiom Solution S A EX550-144BMH-DG,Exiom Solution S A,Mono-c-Si,1,550.0,513.9,2.58,,,72.0,13.99,49.9,13.1,42.0,0.0054561,-0.129241,46.0,1.818942389140513,14.006899059681219,1.66222674347482e-11,0.16576210348595574,137.22727055585023,6.4524211093741135,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Exiom Solution S A EX550-144M-BMH,Exiom Solution S A,Mono-c-Si,1,550.0,515.4,2.58,,,72.0,13.99,49.9,13.1,42.0,0.0060157,-0.126746,45.8,1.8036493449931723,14.007428169645586,1.3167753103464221e-11,0.16840153501891697,135.1798567862289,6.470016221826794,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-267,First Solar Inc,Thin Film,0,67.5,64.8,0.72,1.2,0.6,116.0,1.18,87.0,1.05,64.2,0.00057466,-0.219066,45.9,2.8973180788156974,1.1985930589609954,9.990000000687968e-14,13.579108909517661,861.7919498173649,-11.930504353219844,-0.16723333333333334,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-367,First Solar Inc,Thin Film,0,67.5,64.0,0.72,1.2,0.6,77.0,1.74,60.5,1.41,47.8,1.914e-05,-0.103697,44.9,1.997316160560111,1.7854630820522954,9.990002499566629e-14,4.418029173044997,169.0904007130802,27.017723109569456,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-270,First Solar Inc,Thin Film,0,70.0,67.2,0.72,1.2,0.6,116.0,1.19,89.0,1.07,67.9,0.00057953,-0.22410200000000002,45.9,2.962377704566462,1.203398060465252,9.990000000716104e-14,11.331711160106366,1006.4692815175873,-12.002940585616976,-0.16723333333333334,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-370,First Solar Inc,Thin Film,0,70.0,66.4,0.72,1.2,0.6,77.0,1.74,60.6,1.46,48.1,1.914e-05,-0.1038684,44.9,1.997799112050504,1.7739829112277716,9.99000000213267e-14,4.167597090410918,213.3901621791483,26.820043521499098,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-272,First Solar Inc,Thin Film,0,72.5,69.8,0.72,1.2,0.6,116.0,1.19,90.0,1.07,67.9,0.00056644,-0.21384,44.9,2.9954916690490077,1.20413852091321,9.990000000698812e-14,12.255231631985602,1031.4887777251645,-6.695399461648557,-0.1655,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-372,First Solar Inc,Thin Film,0,72.5,68.8,0.72,1.2,0.6,77.0,1.75,61.4,1.46,49.5,1.9250000000000004e-05,-0.1052396,44.9,2.0243767771497607,1.7805620289224133,9.990000008175348e-14,3.633463013882079,208.05425880993056,26.818151103530568,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-275,First Solar Inc,Thin Film,0,75.0,72.2,0.72,1.2,0.6,116.0,1.2,92.0,1.08,69.4,0.0005712,-0.218592,44.9,3.061089984414367,1.214012527402648,9.990000000691934e-14,12.424970365152614,1064.0453377004374,-6.764453089380847,-0.1655,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-375,First Solar Inc,Thin Film,0,75.0,71.2,0.72,1.2,0.6,77.0,1.76,61.6,1.51,49.8,1.936e-05,-0.10558239999999999,44.9,2.0283185140928435,1.7836054229138774,9.990000163059484e-14,3.470511492461135,258.75834758524957,26.587896700509248,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-377,First Solar Inc,Thin Film,0,77.0,73.1,0.72,1.2,0.6,77.0,1.75,61.7,1.54,50.4,1.9250000000000004e-05,-0.1057538,44.9,2.0300115500363436,1.765965604633766,9.990000003238107e-14,3.0762039158528194,337.1846526918234,26.497504858014057,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-277,First Solar Inc,Thin Film,0,77.5,74.6,0.72,1.2,0.6,116.0,1.21,93.0,1.09,70.9,0.00057596,-0.22096800000000003,44.9,3.0935634863719192,1.2232066251483857,9.99000000069991e-14,11.685080502598556,1070.5950429994264,-6.824939158116011,-0.1655,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-280,First Solar Inc,Thin Film,0,80.0,76.9,0.72,1.2,0.6,116.0,1.22,91.5,1.12,71.2,0.0005941400000000001,-0.23039700000000002,45.9,3.0408383801432266,1.2277370237706688,9.990000006076441e-14,9.80710793008166,1546.417852664002,-12.247392154932168,-0.167233333333333,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-380,First Solar Inc,Thin Film,0,80.0,76.0,0.72,1.2,0.6,77.0,1.76,61.7,1.58,50.7,1.936e-05,-0.1057538,44.9,2.028075463704664,1.7714055955582177,9.990000011569347e-14,2.8193304448672594,435.0515112741568,26.311759045913508,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-382,First Solar Inc,Thin Film,0,82.5,78.4,0.72,1.2,0.6,77.0,1.78,62.0,1.62,51.0,1.9580000000000002e-05,-0.106268,44.9,2.0360933661533154,1.7889813496659632,9.990000013629046e-14,2.746626801102778,544.3497792704819,26.101466421215434,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-385,First Solar Inc,Thin Film,0,85.0,80.8,0.72,1.2,0.6,77.0,1.98,61.0,1.76,48.5,2.178e-05,-0.104554,44.9,1.9978735588933532,2.0008348239994613,9.990000008944543e-14,3.514875499278442,334.02986704274974,25.103910927377093,-0.2246,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-387,First Solar Inc,Thin Film,0,87.5,83.4,0.72,1.2,0.6,77.0,1.98,61.0,1.78,49.2,0.0008514,-0.14395999999999998,48.4,1.9970970688880902,1.995423708032057,9.990000001902793e-14,3.0559036379264413,392.29796049102936,-9.883986207946197,-0.183,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-387-Plus,First Solar Inc,Thin Film,0,87.5,82.8,0.72,1.2,0.6,146.0,2.26,56.0,2.01,43.6,0.00088366,-0.139944,44.6,1.8260133909470824,2.287774220598351,9.990000000411084e-14,3.343360458905683,272.0506453855287,-15.795108402969033,-0.2492,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-390,First Solar Inc,Thin Film,0,90.0,85.8,0.72,1.2,0.6,77.0,2.04,61.0,1.83,49.2,0.0008772,-0.14395999999999998,48.4,1.995317610945405,2.056474769272392,9.990000001758826e-14,2.9723534754640792,368.05377912769563,-10.102969278054925,-0.183,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-390-Plus,First Solar Inc,Thin Film,0,90.0,85.2,0.72,1.2,0.6,146.0,2.27,56.9,2.03,44.4,0.0008875700000000001,-0.1421931,44.6,1.8547117846855743,2.295242699068745,9.990000000507521e-14,3.314895144595247,298.0985495849551,-15.844755339715933,-0.2492,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-490,First Solar Inc,Thin Film,0,90.0,84.9,0.72,1.2,0.6,216.0,1.53,85.5,1.36,66.5,0.0009118800000000001,-0.22477950000000002,44.6,2.9037764204823238,1.5481892842437528,2.301368120257634e-13,7.410291490590444,623.3200732716963,-11.65603751786686,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-490A,First Solar Inc,Thin Film,0,90.0,84.9,0.72,1.2,0.6,216.0,1.53,85.5,1.36,66.5,0.0009118800000000001,-0.22477950000000002,44.6,2.9037764204823238,1.5481892842437528,2.301368120257634e-13,7.410291490590444,623.3200732716963,-11.65603751786686,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-392,First Solar Inc,Thin Film,0,92.5,88.5,0.72,1.2,0.6,77.0,2.06,61.0,1.87,49.5,0.0006592,-0.13237,46.0,1.9938018958795838,2.0727607038997977,9.990000002174387e-14,2.746804787809585,443.4252145058919,-2.121238669964288,-0.19,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-392-Plus,First Solar Inc,Thin Film,0,92.5,87.6,0.72,1.2,0.6,146.0,2.28,57.7,2.05,45.2,0.0008914799999999999,-0.14419230000000002,44.6,1.8801526328065548,2.302558300426753,9.990000000586239e-14,3.239202738005042,327.3908984571628,-15.893149473720666,-0.2492,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-492,First Solar Inc,Thin Film,0,92.5,87.3,0.72,1.2,0.6,216.0,1.54,86.0,1.38,67.0,0.0009178400000000001,-0.22609400000000002,44.6,2.9121615003541415,1.5559464576971205,2.1437336770917091e-13,7.285753814178081,703.6083557804209,-12.249681456591238,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc Fs-492A,First Solar Inc,Thin Film,0,92.5,87.3,0.72,1.2,0.6,216.0,1.54,86.0,1.38,67.0,0.0009178400000000001,-0.22609400000000002,44.6,2.9121615003541415,1.5559464576971205,2.1437336770917091e-13,7.285753814178081,703.6083557804209,-12.249681456591238,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-395,First Solar Inc,Thin Film,0,95.0,90.9,0.72,1.2,0.6,77.0,2.17,60.5,2.0,47.5,0.0006944000000000001,-0.13128499999999999,46.0,1.9726816681518597,2.1821119529349273,9.990000003980988e-14,3.4429823426080253,616.8511162067449,-2.6436322290718537,-0.19,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-395-Plus,First Solar Inc,Thin Film,0,95.0,90.0,0.72,1.2,0.6,146.0,2.29,58.0,2.08,45.8,0.00089539,-0.144942,44.6,1.8889740668314368,2.307695479841426,9.99000000069493e-14,3.024897268827794,391.45673411085505,-15.956830276317067,-0.2492,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-495,First Solar Inc,Thin Film,0,95.0,89.7,0.72,1.2,0.6,216.0,1.55,86.5,1.4,67.9,0.0009238000000000001,-0.2274085,44.6,2.929886987897931,1.5631977442969405,2.193656320567436e-13,6.832947851657615,802.4908603496465,-12.149071715885128,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-495A,First Solar Inc,Thin Film,0,95.0,89.7,0.72,1.2,0.6,216.0,1.55,86.5,1.4,67.9,0.0009238000000000001,-0.2274085,44.6,2.929886987897931,1.5631977442969405,2.193656320567436e-13,6.832947851657615,802.4908603496465,-12.149071715885128,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-397-Plus,First Solar Inc,Thin Film,0,97.5,92.4,0.72,1.2,0.6,146.0,2.29,58.6,2.11,46.3,0.00089539,-0.14644140000000003,44.6,1.9074588168412672,2.3024638373050497,9.990000000648888e-14,3.0118131381211883,553.3650608303684,-16.010564583518,-0.2492,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-497,First Solar Inc,Thin Film,0,97.5,92.1,0.72,1.2,0.6,216.0,1.55,87.0,1.42,68.7,0.0009238000000000001,-0.228723,44.6,2.936659795178535,1.559293559033523,2.0127647094707588e-13,6.5004523620679135,1084.159590821361,-12.82200214884472,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-497A,First Solar Inc,Thin Film,0,97.5,92.1,0.72,1.2,0.6,216.0,1.55,87.0,1.42,68.7,0.0009238000000000001,-0.228723,44.6,2.936659795178535,1.559293559033523,2.0127647094707588e-13,6.5004523620679135,1084.159590821361,-12.82200214884472,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-3100-Plus,First Solar Inc,Thin Film,0,100.0,94.8,0.72,1.2,0.6,146.0,2.33,58.8,2.14,46.8,0.0009110300000000001,-0.1469412,44.6,1.913186526109414,2.3431978337465655,9.990000000395345e-14,2.802105090919159,494.69518928390534,-16.11760497488762,-0.2492,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-4100,First Solar Inc,Thin Film,0,100.0,94.5,0.72,1.2,0.6,216.0,1.57,87.6,1.44,69.4,0.0009357200000000001,-0.23030040000000002,44.6,2.9602893768674376,1.5789178806282012,2.1109556060910714e-13,6.277766789335266,1105.2058526647531,-12.570048859041172,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4100-2,First Solar Inc,Thin Film,0,100.0,92.7,0.72,1.2,0.6,216.0,1.73,84.7,1.51,66.2,0.0007438999999999999,-0.22699600000000003,47.0,3.0260062734358004,1.7539469617174774,1.0904560330799191e-12,6.122915529440073,442.3376964532498,-2.1478180749634332,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4100A,First Solar Inc,Thin Film,0,100.0,94.5,0.72,1.2,0.6,216.0,1.57,87.6,1.44,69.4,0.0009357200000000001,-0.23030040000000002,44.6,2.9602893768674376,1.5789178806282012,2.1109556060910714e-13,6.277766789335266,1105.2058526647531,-12.570048859041172,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4100A-2,First Solar Inc,Thin Film,0,100.0,92.7,0.72,1.2,0.6,216.0,1.73,84.7,1.51,66.2,0.0007438999999999999,-0.22699600000000003,47.0,3.0260062734358004,1.7539469617174774,1.0904560330799191e-12,6.122915529440073,442.3376964532498,-2.1478180749634332,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4102,First Solar Inc,Thin Film,0,102.5,96.9,0.72,1.2,0.6,216.0,1.57,88.0,1.47,70.0,0.0009357200000000001,-0.23135200000000003,44.6,2.9525559255494547,1.5741345284500492,1.7470424015721881e-13,6.033689849542398,2291.1664988474076,-14.01258050405262,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4102-2,First Solar Inc,Thin Film,0,102.5,95.0,0.72,1.2,0.6,216.0,1.74,85.3,1.53,67.0,0.0007481999999999999,-0.228604,47.0,3.0441643337144653,1.7611023193745021,1.0731214215045746e-12,5.863463529548844,483.4741799291317,-2.3432204660206475,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4102A,First Solar Inc,Thin Film,0,102.5,96.9,0.72,1.2,0.6,216.0,1.57,88.0,1.47,70.0,0.0009357200000000001,-0.23135200000000003,44.6,2.9525559255494547,1.5741345284500492,1.7470424015721881e-13,6.033689849542398,2291.1664988474076,-14.01258050405262,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4102A-2,First Solar Inc,Thin Film,0,102.5,95.0,0.72,1.2,0.6,216.0,1.74,85.3,1.53,67.0,0.0007481999999999999,-0.228604,47.0,3.0441643337144653,1.7611023193745021,1.0731214215045746e-12,5.863463529548844,483.4741799291317,-2.3432204660206475,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4105,First Solar Inc,Thin Film,0,105.0,99.3,0.72,1.2,0.6,216.0,1.58,88.2,1.49,70.4,0.0009416800000000001,-0.23187780000000002,44.6,2.9550544365894114,1.58256273571521,1.6985847174217117e-13,5.806598408175613,3579.9343035677784,-14.284532427611827,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4105-2,First Solar Inc,Thin Film,0,105.0,97.4,0.72,1.2,0.6,216.0,1.74,86.0,1.55,67.8,0.0007481999999999999,-0.23048000000000002,47.0,3.0551907278426635,1.757089085393143,9.586433762565275e-13,5.700160856451289,580.386817471459,-3.2816567726554697,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4105-3,First Solar Inc,Thin Film,0,105.0,97.8,0.72,1.2,0.6,216.0,1.81,85.2,1.59,66.2,0.0013140600000000001,-0.30561240000000006,45.77,3.179549082651671,1.8328549365975424,3.806996072733692e-12,5.953173776753679,471.4624580703346,-19.948368597732532,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4105A,First Solar Inc,Thin Film,0,105.0,99.3,0.72,1.2,0.6,216.0,1.58,88.2,1.49,70.4,0.0009416800000000001,-0.23187780000000002,44.6,2.9550544365894114,1.58256273571521,1.6985847174217117e-13,5.806598408175613,3579.9343035677784,-14.284532427611827,-0.2635,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4105A-2,First Solar Inc,Thin Film,0,105.0,97.4,0.72,1.2,0.6,216.0,1.74,86.0,1.55,67.8,0.0007481999999999999,-0.23048000000000002,47.0,3.0551907278426635,1.757089085393143,9.586433762565275e-13,5.700160856451289,580.386817471459,-3.2816567726554697,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4105A-3,First Solar Inc,Thin Film,0,105.0,97.8,0.72,1.2,0.6,216.0,1.81,85.2,1.59,66.2,0.0013140600000000001,-0.30561240000000006,45.77,3.179549082651671,1.8328549365975424,3.806996072733692e-12,5.953173776753679,471.4624580703346,-19.948368597732532,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4107-2,First Solar Inc,Thin Film,0,107.5,99.7,0.72,1.2,0.6,216.0,1.75,86.6,1.57,68.6,0.0007525,-0.23208800000000002,47.0,4.497174433605887,1.7567588031659906,7.214514786836774e-09,3.6148372262763186,935.9624483356683,99.99999826586864,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4107-3,First Solar Inc,Thin Film,0,107.5,100.2,0.72,1.2,0.6,216.0,1.82,85.8,1.61,67.0,0.00132132,-0.3077646,45.77,3.199430514199408,1.8400519523914538,3.7779111388994485e-12,5.7047220690275715,517.7847030150108,-20.045609767097584,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4107A-2,First Solar Inc,Thin Film,0,107.5,99.7,0.72,1.2,0.6,216.0,1.75,86.6,1.57,68.6,0.0007525,-0.23208800000000002,47.0,4.497174433605887,1.7567588031659906,7.214514786836774e-09,3.6148372262763186,935.9624483356683,99.99999826586864,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4107A-3,First Solar Inc,Thin Film,0,107.5,100.2,0.72,1.2,0.6,216.0,1.82,85.8,1.61,67.0,0.00132132,-0.3077646,45.77,3.199430514199408,1.8400519523914538,3.7779111388994485e-12,5.7047220690275715,517.7847030150108,-20.045609767097584,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4110-2,First Solar Inc,Thin Film,0,110.0,102.1,0.72,1.2,0.6,216.0,1.75,87.2,1.59,69.4,0.0007525,-0.23369600000000001,47.0,3.083448732945909,1.76115213755861,8.648340753821517e-13,5.233498315618659,821.24364008945,-4.2034035694308916,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4110-3,First Solar Inc,Thin Film,0,110.0,102.6,0.72,1.2,0.6,216.0,1.82,86.4,1.62,67.8,0.00132132,-0.30991680000000005,45.77,3.2205185164534553,1.837548875024833,3.7634691631216204e-12,5.493453361927458,569.7279824985715,-20.081030234430223,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4110A-2,First Solar Inc,Thin Film,0,110.0,102.1,0.72,1.2,0.6,216.0,1.75,87.2,1.59,69.4,0.0007525,-0.23369600000000001,47.0,3.083448732945909,1.76115213755861,8.648340753821517e-13,5.233498315618659,821.24364008945,-4.2034035694308916,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4110A-3,First Solar Inc,Thin Film,0,110.0,102.6,0.72,1.2,0.6,216.0,1.82,86.4,1.62,67.8,0.00132132,-0.30991680000000005,45.77,3.2205185164534553,1.837548875024833,3.7634691631216204e-12,5.493453361927458,569.7279824985715,-20.081030234430223,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4112-2,First Solar Inc,Thin Film,0,112.5,104.5,0.72,1.2,0.6,216.0,1.75,87.7,1.6,70.2,0.0007525,-0.23503600000000002,47.0,3.1010689674307415,1.7592033911725393,8.702678310025423e-13,4.963606213676088,943.8163307213069,-4.17444523491836,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4112-3,First Solar Inc,Thin Film,0,112.5,104.9,0.72,1.2,0.6,216.0,1.83,87.0,1.64,68.5,0.00132858,-0.31206900000000004,45.77,3.237447830947804,1.8453502442720224,3.6456811188067264e-12,5.327678276072282,635.1463284322463,-20.33600353145193,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4112A-2,First Solar Inc,Thin Film,0,112.5,104.5,0.72,1.2,0.6,216.0,1.75,87.7,1.6,70.2,0.0007525,-0.23503600000000002,47.0,3.1010689674307415,1.7592033911725393,8.702678310025423e-13,4.963606213676088,943.8163307213069,-4.17444523491836,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4112A-3,First Solar Inc,Thin Film,0,112.5,104.9,0.72,1.2,0.6,216.0,1.83,87.0,1.64,68.5,0.00132858,-0.31206900000000004,45.77,3.237447830947804,1.8453502442720224,3.6456811188067264e-12,5.327678276072282,635.1463284322463,-20.33600353145193,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4115-2,First Solar Inc,Thin Film,0,115.0,105.2,0.72,1.2,0.6,216.0,1.78,87.8,1.63,70.5,0.0008081200000000001,-0.3115144,46.3,3.4392137958481594,1.7870936672631421,1.3954203145663427e-11,4.287597641928349,1075.8784759221192,-9.694368747908243,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4115-3,First Solar Inc,Thin Film,0,115.0,107.3,0.72,1.2,0.6,216.0,1.83,87.6,1.66,69.3,0.00132858,-0.31422120000000003,45.77,3.2477735642427312,1.841684924242736,3.347425391321877e-12,5.117113570560784,801.4016758823311,-20.912254731755432,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4115A-2,First Solar Inc,Thin Film,0,115.0,105.2,0.72,1.2,0.6,216.0,1.78,87.8,1.63,70.5,0.0008081200000000001,-0.3115144,46.3,3.4392137958481594,1.7870936672631421,1.3954203145663427e-11,4.287597641928349,1075.8784759221192,-9.694368747908243,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4115A-3,First Solar Inc,Thin Film,0,115.0,107.3,0.72,1.2,0.6,216.0,1.83,87.6,1.66,69.3,0.00132858,-0.31422120000000003,45.77,3.2477735642427312,1.841684924242736,3.347425391321877e-12,5.117113570560784,801.4016758823311,-20.912254731755432,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4117-2,First Solar Inc,Thin Film,0,117.5,107.5,0.72,1.2,0.6,216.0,1.79,88.2,1.65,71.2,0.00081266,-0.3129336,46.3,3.4533327813132653,1.7955354319189605,1.397398166525051e-11,4.0135856908542715,1297.878579117281,-9.742699876091324,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4117-3,First Solar Inc,Thin Film,0,117.5,109.7,0.72,1.2,0.6,216.0,1.83,88.1,1.68,70.1,0.00132858,-0.31601470000000004,45.77,3.256829600637005,1.8382806610738358,3.1369882852594514e-12,4.850241570482073,1071.8881064990626,-21.35474589445319,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4117A-2,First Solar Inc,Thin Film,0,117.5,107.5,0.72,1.2,0.6,216.0,1.79,88.2,1.65,71.2,0.00081266,-0.3129336,46.3,3.4533327813132653,1.7955354319189605,1.397398166525051e-11,4.0135856908542715,1297.878579117281,-9.742699876091324,-0.3878,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4117A-3,First Solar Inc,Thin Film,0,117.5,109.7,0.72,1.2,0.6,216.0,1.83,88.1,1.68,70.1,0.00132858,-0.31601470000000004,45.77,3.256829600637005,1.8382806610738358,3.1369882852594514e-12,4.850241570482073,1071.8881064990626,-21.35474589445319,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4120-3,First Solar Inc,Thin Film,0,120.0,112.1,0.72,1.2,0.6,216.0,1.84,88.7,1.7,70.8,0.00133584,-0.31816690000000003,45.77,3.2741341777674378,1.8466425382672673,3.0515386734338213e-12,4.697476633226664,1301.2129865171758,-21.580415180607556,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4120A-3,First Solar Inc,Thin Film,0,120.0,112.1,0.72,1.2,0.6,216.0,1.84,88.7,1.7,70.8,0.00133584,-0.31816690000000003,45.77,3.2741341777674378,1.8466425382672673,3.0515386734338213e-12,4.697476633226664,1301.2129865171758,-21.580415180607556,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4122-3,First Solar Inc,Thin Film,0,122.5,114.5,0.72,1.2,0.6,216.0,1.85,88.7,1.71,71.5,0.0013431,-0.31816690000000003,45.77,3.2921757585300546,1.8560219992101648,3.557251108344719e-12,4.193719892080458,1288.3398972207556,-20.628029943962805,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-4122A-3,First Solar Inc,Thin Film,0,122.5,114.5,0.72,1.2,0.6,216.0,1.85,88.7,1.71,71.5,0.0013431,-0.31816690000000003,45.77,3.2921757585300546,1.8560219992101648,3.557251108344719e-12,4.193719892080458,1288.3398972207556,-20.628029943962805,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6385,First Solar Inc,CdTe,0,385.0,358.5,2.48,,,264.0,2.49,214.3,2.23,172.8,0.0013707450000000003,-0.5989685000000001,50.37,7.348383976364568,2.5093342221199193,4.98709788992431e-13,8.240336936787475,1061.2497805012158,-14.871753492157554,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6390,First Solar Inc,CdTe,0,390.0,363.2,2.48,,,264.0,2.49,214.8,2.24,173.9,0.0013707450000000003,-0.6003660000000001,50.37,7.364758597051169,2.5072492530013064,4.996403640945458e-13,7.89488193874927,1139.6583976059212,-14.870659162844573,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6390A,First Solar Inc,CdTe,0,390.0,365.6,2.48,,,264.0,2.49,214.8,2.24,173.9,0.0014143200000000002,-0.5946738,49.64,7.234202504451064,2.5077314520809457,2.9496094989994823e-13,8.027284437290978,1127.2589612255467,-17.768304223017072,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6395,First Solar Inc,CdTe,0,395.0,368.0,2.48,,,264.0,2.5,215.4,2.26,175.0,0.00137625,-0.602043,50.37,7.3810955511548855,2.515329921905106,4.960136643743562e-13,7.567299939032316,1234.073465753688,-14.96430198866484,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6395A,First Solar Inc,CdTe,0,395.0,370.4,2.48,,,264.0,2.5,215.4,2.26,175.0,0.0014200000000000003,-0.5963348999999999,49.64,7.250344645115302,2.515781642889696,2.9284355928349373e-13,7.698926343390215,1219.6015331237338,-17.859064678685098,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6400,First Solar Inc,CdTe,0,400.0,372.7,2.48,,,264.0,2.51,216.1,2.27,176.1,0.001381755,-0.6039995,50.37,7.415313139951091,2.524746371130377,5.185653408733473e-13,7.291994716337967,1241.1803950541394,-14.678044087448601,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6400A,First Solar Inc,CdTe,0,400.0,375.2,2.48,,,264.0,2.51,216.1,2.27,176.1,0.00142568,-0.59827285,49.64,7.283873291885682,2.525191270579609,3.062780696807816e-13,7.424022973704654,1226.6451032592965,-17.57752898380869,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6400A-P-x,First Solar Inc,CdTe,0,400.0,367.3,2.52,,,264.0,2.51,216.1,2.27,176.1,0.0014143849999999998,-0.6089698,50.71,7.852886652122055,2.5233249738144874,2.6365376365766797e-12,6.858504713224405,1291.9235037196752,-3.3089079360446094,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6400-P,First Solar Inc,CdTe,0,400.0,374.2,2.52,,,264.0,2.51,216.1,2.27,176.1,0.0013302999999999998,-0.5854149,47.33,7.549781215635177,2.5242998900641367,8.720292505571992e-13,7.157805142694148,1256.3796531638843,-8.052804583150673,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6400-P-I,First Solar Inc,CdTe,0,400.0,374.2,2.52,,,264.0,2.51,216.1,2.27,176.1,0.0013302999999999998,-0.5854149,47.33,7.549781215635177,2.5242998900641367,8.720292505571992e-13,7.157805142694148,1256.3796531638843,-8.052804583150673,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6405,First Solar Inc,CdTe,0,405.0,377.5,2.48,,,264.0,2.52,216.8,2.29,177.2,0.00138726,-0.605956,50.37,7.433288338792953,2.533080029778011,5.111837770484904e-13,7.018529895962613,1352.1907552798814,-14.821845646843814,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6405A,First Solar Inc,CdTe,0,405.0,379.9,2.48,,,264.0,2.52,216.8,2.29,177.2,0.00143136,-0.6002108,49.64,7.301636738248031,2.5334961615975393,3.0191852766195874e-13,7.149761449883776,1335.001713499097,-17.7176777898167,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6405A-P-x,First Solar Inc,CdTe,0,405.0,372.0,2.52,,,264.0,2.52,216.8,2.29,177.2,0.00142002,-0.6109424,50.71,7.8716132666009715,2.531752864310029,2.5996809881190783e-12,6.587605552142853,1412.48682701574,-3.466172033421224,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6405-P,First Solar Inc,CdTe,0,405.0,378.9,2.52,,,264.0,2.52,216.8,2.29,177.2,0.0013356,-0.5873112,47.33,7.568014776698539,2.532662646534274,8.597648225489439e-13,6.885108126095902,1370.2090192167261,-8.205429659688233,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6405-P-I,First Solar Inc,CdTe,0,405.0,378.9,2.52,,,264.0,2.52,216.8,2.29,177.2,0.0013356,-0.5873112,47.33,7.568014776698539,2.532662646534274,8.597648225489439e-13,6.885108126095902,1370.2090192167261,-8.205429659688233,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6410,First Solar Inc,CdTe,0,410.0,382.2,2.48,,,264.0,2.52,217.4,2.3,178.3,0.00138726,-0.6076330000000001,50.37,7.451122584848237,2.5314939385254465,5.081786611258472e-13,6.732493490402514,1476.0722414787692,-14.876331265926938,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6410A,First Solar Inc,CdTe,0,410.0,384.7,2.48,,,264.0,2.52,217.4,2.3,178.3,0.00143136,-0.6018718999999999,49.64,7.319226707954458,2.531881219543976,3.0017145228766553e-13,6.8635975725075715,1455.7651950841223,-17.770178736165875,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6410A-P-x,First Solar Inc,CdTe,0,410.0,376.7,2.52,,,264.0,2.52,217.4,2.3,178.3,0.00142002,-0.6126332,50.71,7.890308802349319,2.53026119362692,2.5842617533959063e-12,6.301935930810152,1547.6638633914997,-3.526562775582398,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6410-P,First Solar Inc,CdTe,0,410.0,383.7,2.52,,,264.0,2.52,217.4,2.3,178.3,0.0013356,-0.5889365999999999,47.33,7.586106052257643,2.5311058401884403,8.546637689849718e-13,6.599193619503091,1497.4074585400294,-8.264210198118514,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6410-P-I,First Solar Inc,CdTe,0,410.0,383.7,2.52,,,264.0,2.52,217.4,2.3,178.3,0.0013356,-0.5889365999999999,47.33,7.586106052257643,2.5311058401884403,8.546637689849718e-13,6.599193619503091,1497.4074585400294,-8.264210198118514,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6415,First Solar Inc,CdTe,0,415.0,387.0,2.48,,,264.0,2.53,218.1,2.31,179.3,0.001392765,-0.6095895000000001,50.37,7.482952278878211,2.541103471471621,5.261454143204353e-13,6.5159649850739045,1484.7060634120617,-14.658712749983158,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6415A,First Solar Inc,CdTe,0,415.0,389.5,2.48,,,264.0,2.53,218.1,2.31,179.3,0.00143704,-0.60380985,49.64,7.350429076258099,2.5414854420048254,3.1087585419830826e-13,6.647344099711416,1464.2693393589936,-17.556178547575005,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6415A-P-x,First Solar Inc,CdTe,0,415.0,381.4,2.52,,,264.0,2.53,218.1,2.31,179.3,0.0014256549999999998,-0.6146058,50.71,7.924252517746352,2.5398882945978727,2.6732677319924056e-12,6.084476969473747,1556.762554479708,-3.291207764958692,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6415-P,First Solar Inc,CdTe,0,415.0,388.5,2.52,,,264.0,2.53,218.1,2.31,179.3,0.0013409,-0.5908329,47.33,7.618485812170204,2.540721057586085,8.84308575160832e-13,6.38247539604431,1506.1632336444927,-8.036261371818522,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6415-P-I,First Solar Inc,CdTe,0,415.0,388.5,2.52,,,264.0,2.53,218.1,2.31,179.3,0.0013409,-0.5908329,47.33,7.618485812170204,2.540721057586085,8.84308575160832e-13,6.38247539604431,1506.1632336444927,-8.036261371818522,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6420,First Solar Inc,CdTe,0,420.0,395.1,2.475,,,264.0,2.54,218.5,2.33,180.4,0.00125222,-0.5975975000000001,48.8,7.286504862376189,2.550063397079395,2.287973228380871e-13,6.330646208612435,1597.8542083024015,-18.580848098765383,-0.2453,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6420A,First Solar Inc,CdTe,0,420.0,394.2,2.48,,,264.0,2.54,218.5,2.33,180.4,0.0014427200000000002,-0.60491725,49.64,7.3633155050420385,2.549856329568047,3.1295254235209223e-13,6.254606289679407,1611.827188848326,-17.550973559011194,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6420A-P-B,First Solar Inc,CdTe,0,420.0,388.1,2.52,,,268.0,2.54,218.5,2.33,180.4,0.00128524,-0.5914795,50.1,7.765630681229473,2.5488143619781303,1.4590093712169863e-12,5.860940404769871,1688.9241308063176,-4.116437027167525,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6420A-P-B-2,First Solar Inc,Thin Film,0,420.0,398.3,2.52,,,268.0,2.648,224.163,2.408,174.404,0.0008685440000000002,-0.5070567060000001,46.99,7.2655403836994035,2.670093484749916,9.990000001896226e-14,11.32970266844831,1357.9140192393,-8.146916918524319,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6420A-P-x,First Solar Inc,CdTe,0,420.0,386.1,2.52,,,264.0,2.53,218.1,2.31,179.3,0.0014256549999999998,-0.6146058,50.71,7.924252517746352,2.5398882945978727,2.6732677319924056e-12,6.084476969473747,1556.762554479708,-3.291207764958692,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6420-P,First Solar Inc,CdTe,0,420.0,393.2,2.52,,,264.0,2.53,218.1,2.31,179.3,0.0013409,-0.5908329,47.33,7.618485812170204,2.540721057586085,8.84308575160832e-13,6.38247539604431,1506.1632336444927,-8.036261371818522,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6420-P-B-2,First Solar Inc,Thin Film,0,420.0,398.5,2.52,,,268.0,2.648,224.163,2.408,174.404,0.0008685440000000002,-0.5070567060000001,46.83,7.2655403836994035,2.670093484749916,9.990000001896226e-14,11.32970266844831,1357.9140192393,-8.146916918524319,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6420-P-I,First Solar Inc,CdTe,0,420.0,393.2,2.52,,,264.0,2.53,218.1,2.31,179.3,0.0013409,-0.5908329,47.33,7.618485812170204,2.540721057586085,8.84308575160832e-13,6.38247539604431,1506.1632336444927,-8.036261371818522,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6425,First Solar Inc,CdTe,0,425.0,396.5,2.48,,,264.0,2.54,218.9,2.34,181.5,0.0013982700000000003,-0.6118255,50.37,7.5103555662529935,2.5480771167642033,5.333145782710454e-13,5.760977570762202,1811.6468367022267,-14.617333590362575,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6425A,First Solar Inc,CdTe,0,425.0,399.0,2.48,,,264.0,2.54,218.9,2.34,181.5,0.0014427200000000002,-0.6060246499999999,49.64,7.377442841279722,2.5483991188743764,3.152298907096549e-13,5.891597235336323,1781.6936759329715,-17.513412302709824,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6425A-P-B,First Solar Inc,CdTe,0,425.0,392.8,2.52,,,268.0,2.54,218.9,2.34,181.5,0.00128524,-0.5925623,50.1,7.780375859964422,2.5474461048795067,1.4686242617670294e-12,5.498180563434765,1875.5280607887387,-4.079036763893172,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6425A-P-B-2,First Solar Inc,Thin Film,0,425.0,403.2,2.52,,,268.0,2.656,224.827,2.422,175.439,0.0008711680000000001,-0.5085586740000001,46.99,7.2856597352324295,2.6764708966064426,9.990000000361208e-14,11.069725641900964,1436.2434571572699,-8.180221909651417,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6425A-P-x,First Solar Inc,CdTe,0,425.0,390.8,2.52,,,264.0,2.54,218.9,2.34,181.5,0.00143129,-0.6168602,50.71,7.953072932370548,2.5470584851171174,2.707920931546676e-12,5.331856821850609,1918.6718008522162,-3.2489546057293266,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6425-P,First Solar Inc,CdTe,0,425.0,398.0,2.52,,,264.0,2.54,218.9,2.34,181.5,0.0013462,-0.5930000999999999,47.33,7.646246710477942,2.547755708662217,8.959018373255947e-13,5.628297557165723,1843.2713794598048,-7.995978156490997,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6425-P-B-2,First Solar Inc,Thin Film,0,425.0,403.3,2.52,,,268.0,2.656,224.827,2.422,175.439,0.0008711680000000001,-0.5085586740000001,46.83,7.2856597352324295,2.6764708966064426,9.990000000361208e-14,11.069725641900964,1436.2434571572699,-8.180221909651417,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6425-P-I,First Solar Inc,CdTe,0,425.0,398.0,2.52,,,264.0,2.54,218.9,2.34,181.5,0.0013462,-0.5930000999999999,47.33,7.646246710477942,2.547755708662217,8.959018373255947e-13,5.628297557165723,1843.2713794598048,-7.995978156490997,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6430,First Solar Inc,CdTe,0,430.0,401.3,2.475,,,264.0,2.54,219.2,2.36,182.6,0.0013982700000000003,-0.612664,50.37,7.507420453638964,2.5459262763445545,5.114864694154502e-13,5.363759461994588,2298.9054589913003,-14.940425250599652,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6430A,First Solar Inc,CdTe,0,430.0,403.8,2.48,,,264.0,2.54,219.2,2.36,182.6,0.0014427200000000002,-0.6068551999999999,49.64,7.374760822197043,2.546198247699097,3.0228972898803707e-13,5.493207015859914,2251.079095577878,-17.82912005211353,-0.24445,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6430A-P-B,First Solar Inc,CdTe,0,430.0,397.5,2.52,,,268.0,2.54,219.2,2.36,182.6,0.00128524,-0.5933744,50.1,7.777054822245987,2.5453955339448124,1.4096276996139516e-12,5.103193961246249,2402.3781165486002,-4.431210288146721,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6430A-P-B-2,First Solar Inc,Thin Film,0,430.0,408.0,2.52,,,268.0,2.664,225.484,2.437,176.468,0.0008737920000000001,-0.5100448080000001,46.99,7.305436677666749,2.6827263357897904,9.990000002002632e-14,10.809562654569458,1537.763460212253,-8.215246403455602,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6430A-P-x,First Solar Inc,CdTe,0,430.0,395.5,2.52,,,264.0,2.54,219.2,2.36,182.6,0.00143129,-0.6177056,50.71,7.9493667948873785,2.545071545718972,2.5992248914888542e-12,4.9384131857273585,2473.322772130135,-3.6008712419940014,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6430-P,First Solar Inc,CdTe,0,430.0,402.8,2.52,,,264.0,2.54,219.2,2.36,182.6,0.0013462,-0.5938127999999999,47.33,7.643163172391127,2.5456554224383003,8.597209063581814e-13,5.23216220360414,2349.9026183507394,-8.337522889418631,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6430-P-B-2,First Solar Inc,Thin Film,0,430.0,408.1,2.52,,,268.0,2.664,225.484,2.437,176.468,0.0008737920000000001,-0.5100448080000001,46.83,7.305436677666749,2.6827263357897904,9.990000002002632e-14,10.809562654569458,1537.763460212253,-8.215246403455602,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6430-P-I,First Solar Inc,CdTe,0,430.0,402.8,2.52,,,264.0,2.54,219.2,2.36,182.6,0.0013462,-0.5938127999999999,47.33,7.643163172391127,2.5456554224383003,8.597209063581814e-13,5.23216220360414,2349.9026183507394,-8.337522889418631,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435,First Solar Inc,CdTe,0,435.0,409.4,2.475,,,264.0,2.55,219.6,2.37,183.6,0.0012571499999999998,-0.6006060000000001,48.8,7.323262193402543,2.5559880223777935,2.3305998139581583e-13,5.2373726315435825,2230.335721967966,-18.522089835576715,-0.2453,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435A,First Solar Inc,CdTe,0,435.0,409.9,2.475,,,264.0,2.55,219.6,2.37,183.6,0.0013438499999999997,-0.5944572,51.0,7.122755212756649,2.5564060450507466,1.0009278677582599e-13,5.435055422421519,2163.486397408076,-23.405308479112577,-0.2201,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435A-P-B,First Solar Inc,CdTe,0,435.0,402.3,2.52,,,268.0,2.55,219.6,2.37,183.6,0.0012902999999999999,-0.5944572,50.1,7.804515384641184,2.555051768203218,1.4846709398074566e-12,4.770715695611281,2408.132073370918,-4.054738721877555,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435A-P-B-2,First Solar Inc,Thin Film,0,435.0,412.8,2.52,,,268.0,2.672,226.136,2.451,177.491,0.0008764160000000001,-0.511519632,46.99,7.325168069592057,2.6892408227173332,9.990000000361596e-14,10.55655565655351,1636.065585999813,-8.248470187008868,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6435A-P-x,First Solar Inc,CdTe,0,435.0,400.2,2.52,,,264.0,2.55,219.6,2.37,183.6,0.001436925,-0.6188328000000001,50.71,7.977783465963691,2.5547372156063624,2.7380271247347858e-12,4.605296024945713,2478.9888960901935,-3.2216366435124892,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435-P,First Solar Inc,CdTe,0,435.0,407.6,2.52,,,264.0,2.55,219.6,2.37,183.6,0.0013514999999999998,-0.5948964,47.33,7.670065874438603,2.555303975447293,9.059657083488665e-13,4.900005671898631,2355.78286448327,-7.970228620781852,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435-P-B,First Solar Inc,CdTe,0,435.0,402.3,2.52,,,268.0,2.55,219.6,2.37,183.6,0.0012902999999999999,-0.5944572,50.1,7.804515384641184,2.555051768203218,1.4846709398074566e-12,4.770715695611281,2408.132073370918,-4.054738721877555,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6435-P-B-2,First Solar Inc,Thin Film,0,435.0,413.0,2.52,,,268.0,2.672,226.136,2.451,177.491,0.0008764160000000001,-0.511519632,46.83,7.325168069592057,2.6892408227173332,9.990000000361596e-14,10.55655565655351,1636.065585999813,-8.248470187008868,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6435-P-I,First Solar Inc,CdTe,0,435.0,407.6,2.52,,,264.0,2.55,219.6,2.37,183.6,0.0013514999999999998,-0.5948964,47.33,7.670065874438603,2.555303975447293,9.059657083488665e-13,4.900005671898631,2355.78286448327,-7.970228620781852,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440,First Solar Inc,CdTe,0,440.0,414.2,2.475,,,264.0,2.55,220.0,2.38,184.7,0.0012571499999999998,-0.6017000000000001,48.8,7.3369699861839255,2.5548774128587315,2.3447778445248756e-13,4.886115656372907,2554.5499811636223,-18.494022437348676,-0.2453,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440A,First Solar Inc,CdTe,0,440.0,414.7,2.475,,,264.0,2.55,220.0,2.38,184.7,0.0013438499999999997,-0.5955400000000001,51.0,7.136144178810352,2.5552528084953767,1.0073003505600115e-13,5.083671318012635,2467.891580950763,-23.37668558951363,-0.2201,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440A-P-B,First Solar Inc,CdTe,0,440.0,407.0,2.52,,,268.0,2.55,220.0,2.38,184.7,0.0012902999999999999,-0.5955400000000001,50.1,7.819050118232584,2.554041557933705,1.4931850660758244e-12,4.419692299749754,2788.5819188175738,-4.0245271302155645,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440A-P-B-2,First Solar Inc,Thin Film,0,440.0,417.6,2.52,,,268.0,2.679,226.782,2.465,178.508,0.000878712,-0.512980884,46.99,7.3446884102790815,2.6946488617238447,9.990000002178702e-14,10.307870125718978,1764.6512930827357,-8.280359777234278,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6440A-P-B-I,First Solar Inc,CdTe,0,440.0,407.0,2.52,,,268.0,2.55,220.0,2.38,184.7,0.0012902999999999999,-0.5955400000000001,50.1,7.819050118232584,2.554041557933705,1.4931850660758244e-12,4.419692299749754,2788.5819188175738,-4.0245271302155645,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440A-P-x,First Solar Inc,CdTe,0,440.0,405.0,2.52,,,264.0,2.56,220.0,2.38,184.7,0.00144256,-0.6199600000000001,50.71,8.008416407724614,2.5643584231272993,2.905089995710577e-12,4.226919678738435,2482.7590351596573,-2.7836873795737556,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440-P,First Solar Inc,CdTe,0,440.0,412.3,2.52,,,264.0,2.56,220.0,2.38,184.7,0.0013568,-0.59598,47.33,7.699033518405995,2.564905931109478,9.616619428239306e-13,4.5228387927429505,2360.0957818697743,-7.546045134637027,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440-P-B,First Solar Inc,CdTe,0,440.0,407.0,2.52,,,268.0,2.55,220.0,2.38,184.7,0.0012902999999999999,-0.5955400000000001,50.1,7.819050118232584,2.554041557933705,1.4931850660758244e-12,4.419692299749754,2788.5819188175738,-4.0245271302155645,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6440-P-B-2,First Solar Inc,Thin Film,0,440.0,417.8,2.52,,,268.0,2.679,226.782,2.465,178.508,0.000878712,-0.512980884,46.83,7.3446884102790815,2.6946488617238447,9.990000002178702e-14,10.307870125718978,1764.6512930827357,-8.280359777234278,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6440-P-I,First Solar Inc,CdTe,0,440.0,412.3,2.52,,,264.0,2.56,220.0,2.38,184.7,0.0013568,-0.59598,47.33,7.699033518405995,2.564905931109478,9.616619428239306e-13,4.5228387927429505,2360.0957818697743,-7.546045134637027,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445A,First Solar Inc,CdTe,0,445.0,419.5,2.475,,,264.0,2.56,220.4,2.4,185.7,0.0013491199999999999,-0.5966228,51.0,7.146741298386938,2.5642242235948864,1.0058291796139811e-13,4.7644992206257255,2887.422441575895,-23.425918708251718,-0.2201,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445A-P-B,First Solar Inc,CdTe,0,445.0,411.7,2.52,,,268.0,2.56,220.4,2.4,185.7,0.00129536,-0.5966228,50.1,7.830381187756671,2.5631501760427327,1.490872986432757e-12,4.1043511685395195,3335.4132793051526,-4.083636595756104,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445A-P-B-2,First Solar Inc,Thin Film,0,445.0,422.4,2.52,,,268.0,2.687,227.422,2.479,179.519,0.000881336,-0.514428564,46.99,7.364031886678292,2.701291643463967,9.990000002278621e-14,10.06144534744216,1891.6721317791998,-8.313500358018448,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6445A-P-B-I,First Solar Inc,CdTe,0,445.0,411.7,2.52,,,268.0,2.56,220.4,2.4,185.7,0.00129536,-0.5966228,50.1,7.830381187756671,2.5631501760427327,1.490872986432757e-12,4.1043511685395195,3335.4132793051526,-4.083636595756104,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445A-P-x,First Solar Inc,CdTe,0,445.0,409.7,2.52,,,264.0,2.56,220.4,2.4,185.7,0.00144256,-0.6210872000000001,50.71,8.004205873772824,2.5629052712734968,2.7498769120177127e-12,3.9398955553031882,3471.6663939846235,-3.2480883825542963,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445-P,First Solar Inc,CdTe,0,445.0,417.1,2.52,,,264.0,2.56,220.4,2.4,185.7,0.0013568,-0.5970636,47.33,7.695582601552755,2.563347825385285,9.099231054598628e-13,4.232807451822722,3236.7240935671516,-7.996666322494042,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445-P-B,First Solar Inc,CdTe,0,445.0,411.7,2.52,,,268.0,2.56,220.4,2.4,185.7,0.00129536,-0.5966228,50.1,7.830381187756671,2.5631501760427327,1.490872986432757e-12,4.1043511685395195,3335.4132793051526,-4.083636595756104,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6445-P-B-2,First Solar Inc,Thin Film,0,445.0,422.6,2.52,,,268.0,2.687,227.422,2.479,179.519,0.000881336,-0.514428564,46.83,7.364031886678292,2.701291643463967,9.990000002278621e-14,10.06144534744216,1891.6721317791998,-8.313500358018448,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6445-P-I,First Solar Inc,CdTe,0,445.0,417.1,2.52,,,264.0,2.56,220.4,2.4,185.7,0.0013568,-0.5970636,47.33,7.695582601552755,2.563347825385285,9.099231054598628e-13,4.232807451822722,3236.7240935671516,-7.996666322494042,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450A,First Solar Inc,CdTe,0,450.0,424.3,2.475,,,264.0,2.57,221.1,2.41,186.8,0.00135439,-0.5985176999999999,51.0,7.177977336529364,2.574005455316564,1.0475662183606187e-13,4.522234804997561,2901.5786050616416,-23.18533807430815,-0.2201,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450A-P-B,First Solar Inc,CdTe,0,450.0,416.5,2.52,,,268.0,2.57,221.1,2.41,186.8,0.00130042,-0.5985176999999999,50.1,7.865041462100834,2.5729604624282034,1.5501648741762637e-12,3.8603008359620787,3351.156585285537,-3.807474502141218,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450A-P-B-2,First Solar Inc,Thin Film,0,450.0,427.3,2.52,,,268.0,2.694,228.058,2.493,180.525,0.0008836320000000001,-0.5158671960000001,46.99,7.3832294205026585,2.70683440880888,9.99000001289732e-14,9.819546524933049,2061.166879859917,-8.34532872336903,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6450A-P-B-I,First Solar Inc,CdTe,0,450.0,416.5,2.52,,,268.0,2.57,221.1,2.41,186.8,0.00130042,-0.5985176999999999,50.1,7.865041462100834,2.5729604624282034,1.5501648741762637e-12,3.8603008359620787,3351.156585285537,-3.807474502141218,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450A-P-x,First Solar Inc,CdTe,0,450.0,414.4,2.52,,,264.0,2.57,221.1,2.41,186.8,0.001448195,-0.6230597999999999,50.71,8.039889072364524,2.5727227189319146,2.8595348011551496e-12,3.695255317072403,3487.9862461259318,-2.9699585329971723,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450-P,First Solar Inc,CdTe,0,450.0,421.9,2.52,,,264.0,2.57,221.1,2.41,186.8,0.0013621,-0.5989598999999999,47.33,7.729581151551639,2.573152375541919,9.464664936545195e-13,3.9890925207980543,3252.1403781403287,-7.727299514740024,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450-P-B,First Solar Inc,CdTe,0,450.0,416.5,2.52,,,268.0,2.57,221.1,2.41,186.8,0.00130042,-0.5985176999999999,50.1,7.865041462100834,2.5729604624282034,1.5501648741762637e-12,3.8603008359620787,3351.156585285537,-3.807474502141218,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6450-P-B-2,First Solar Inc,Thin Film,0,450.0,427.4,2.52,,,268.0,2.694,228.058,2.493,180.525,0.0008836320000000001,-0.5158671960000001,46.83,7.3832294205026585,2.70683440880888,9.99000001289732e-14,9.819546524933049,2061.166879859917,-8.34532872336903,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6450-P-I,First Solar Inc,CdTe,0,450.0,421.9,2.52,,,264.0,2.57,221.1,2.41,186.8,0.0013621,-0.5989598999999999,47.33,7.729581151551639,2.573152375541919,9.464664936545195e-13,3.9890925207980543,3252.1403781403287,-7.727299514740024,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6455A-P-B,First Solar Inc,CdTe,0,455.0,421.2,2.52,,,268.0,2.58,222.0,2.42,187.8,0.00130548,-0.6009540000000001,50.1,7.9011198094363415,2.582859859992085,1.5791572984452118e-12,3.748698335582449,3381.858463342026,-3.6925689050279993,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6455A-P-B-2,First Solar Inc,Thin Film,0,455.0,432.1,2.52,,,268.0,2.702,228.688,2.507,181.525,0.0008862560000000001,-0.5172922560000001,46.99,7.40225001988067,2.713597992880179,9.990000002152913e-14,9.579801406591178,2231.819218867736,-8.378373972448788,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6455A-P-B-I,First Solar Inc,CdTe,0,455.0,421.2,2.52,,,268.0,2.58,222.0,2.42,187.8,0.00130548,-0.6009540000000001,50.1,7.9011198094363415,2.582859859992085,1.5791572984452118e-12,3.748698335582449,3381.858463342026,-3.6925689050279993,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6455A-P-x,First Solar Inc,CdTe,0,455.0,419.1,2.52,,,264.0,2.58,222.0,2.42,187.8,0.00145383,-0.625596,50.71,8.076877570299791,2.5826257872268528,2.9131685861618457e-12,3.583341042291084,3520.856456581787,-2.854152300550009,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6455-P,First Solar Inc,CdTe,0,455.0,426.7,2.52,,,264.0,2.58,222.0,2.42,187.8,0.0013674,-0.601398,47.33,7.765016770519843,2.5830488550805732,9.643375936892579e-13,3.8776746128295376,3281.3630839858306,-7.615089473863473,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6455-P-B,First Solar Inc,CdTe,0,455.0,421.2,2.52,,,268.0,2.58,222.0,2.42,187.8,0.00130548,-0.6009540000000001,50.1,7.9011198094363415,2.582859859992085,1.5791572984452118e-12,3.748698335582449,3381.858463342026,-3.6925689050279993,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6455-P-B-2,First Solar Inc,Thin Film,0,455.0,432.3,2.52,,,268.0,2.702,228.688,2.507,181.525,0.0008862560000000001,-0.5172922560000001,46.83,7.40225001988067,2.713597992880179,9.990000002152913e-14,9.579801406591178,2231.819218867736,-8.378373972448788,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6455-P-I,First Solar Inc,CdTe,0,455.0,426.7,2.52,,,264.0,2.58,222.0,2.42,187.8,0.0013674,-0.601398,47.33,7.765016770519843,2.5830488550805732,9.643375936892579e-13,3.8776746128295376,3281.3630839858306,-7.615089473863473,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6460A-P-B,First Solar Inc,CdTe,0,460.0,426.0,2.52,,,268.0,2.59,222.9,2.44,188.8,0.00131054,-0.6033903,50.1,7.921344856923027,2.59223130300719,1.5278739641965235e-12,3.650482227342088,4237.321848681782,-4.000005544652052,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6460A-P-B-2,First Solar Inc,Thin Film,0,460.0,436.9,2.52,,,268.0,2.709,229.312,2.52,182.52,0.0008885520000000001,-0.5187037440000001,46.99,7.42117348848065,2.7194233024556382,9.990000013716058e-14,9.346253836484454,2429.076751378473,-8.408359486753245,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6460A-P-B-I,First Solar Inc,CdTe,0,460.0,426.0,2.52,,,268.0,2.59,222.9,2.44,188.8,0.00131054,-0.6033903,50.1,7.921344856923027,2.59223130300719,1.5278739641965235e-12,3.650482227342088,4237.321848681782,-4.000005544652052,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6460A-P-x,First Solar Inc,CdTe,0,460.0,423.8,2.52,,,264.0,2.59,222.9,2.44,188.8,0.0014594649999999999,-0.6281322,50.71,8.097269411708002,2.5920254089151205,2.81844301212679e-12,3.486342564938895,4458.174940286337,-3.1624702492772414,-0.307,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6460-P,First Solar Inc,CdTe,0,460.0,431.5,2.52,,,264.0,2.59,222.9,2.44,188.8,0.0013727,-0.6038361,47.33,7.78500598787949,2.5923984431431735,9.32715399620372e-13,3.778608051674583,4080.394772214543,-7.914235276534559,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6460-P-B,First Solar Inc,CdTe,0,460.0,426.0,2.52,,,268.0,2.59,222.9,2.44,188.8,0.00131054,-0.6033903,50.1,7.921344856923027,2.59223130300719,1.5278739641965235e-12,3.650482227342088,4237.321848681782,-4.000005544652052,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6460-P-B-2,First Solar Inc,Thin Film,0,460.0,437.1,2.52,,,268.0,2.709,229.312,2.52,182.52,0.0008885520000000001,-0.5187037440000001,46.83,7.42117348848065,2.7194233024556382,9.990000013716058e-14,9.346253836484454,2429.076751378473,-8.408359486753245,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6460-P-I,First Solar Inc,CdTe,0,460.0,431.5,2.52,,,264.0,2.59,222.9,2.44,188.8,0.0013727,-0.6038361,47.33,7.78500598787949,2.5923984431431735,9.32715399620372e-13,3.778608051674583,4080.394772214543,-7.914235276534559,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6465A-P,First Solar Inc,CdTe,0,465.0,437.9,2.52,,,268.0,2.6,223.8,2.45,189.8,0.0014664,-0.6197022,46.58,7.8020636776215,2.6023380117065025,8.882639837186611e-13,3.6867622721924125,4099.886194107673,-10.36309873780049,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6465A-P-B,First Solar Inc,CdTe,0,465.0,430.7,2.52,,,268.0,2.6,223.8,2.45,189.8,0.0013156,-0.6058266,50.1,7.957382035897646,2.602151248229506,1.5561765708485394e-12,3.5412145068470764,4279.914140963748,-3.8863989556922407,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6465A-P-B-2,First Solar Inc,Thin Film,0,465.0,441.7,2.52,,,268.0,2.716,229.934,2.534,183.509,0.0008908480000000002,-0.520110708,46.99,7.439919143667582,2.7251511338951997,9.990000002472203e-14,9.114577479830166,2705.1502829547753,-8.440079887816207,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6465A-P-B-I,First Solar Inc,CdTe,0,465.0,430.7,2.52,,,268.0,2.6,223.8,2.45,189.8,0.0013156,-0.6058266,50.1,7.957382035897646,2.602151248229506,1.5561765708485394e-12,3.5412145068470764,4279.914140963748,-3.8863989556922407,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6465A-P-I,First Solar Inc,CdTe,0,465.0,437.9,2.52,,,268.0,2.6,223.8,2.45,189.8,0.0014664,-0.6197022,46.58,7.8020636776215,2.6023380117065025,8.882639837186611e-13,3.6867622721924125,4099.886194107673,-10.36309873780049,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6465-P-B,First Solar Inc,CdTe,0,465.0,430.7,2.52,,,268.0,2.6,223.8,2.45,189.8,0.0013156,-0.6058266,50.1,7.957382035897646,2.602151248229506,1.5561765708485394e-12,3.5412145068470764,4279.914140963748,-3.8863989556922407,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6465-P-B-2,First Solar Inc,Thin Film,0,465.0,441.9,2.52,,,268.0,2.716,229.934,2.534,183.509,0.0008908480000000002,-0.520110708,46.83,7.439919143667582,2.7251511338951997,9.990000002472203e-14,9.114577479830166,2705.1502829547753,-8.440079887816207,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6470A-P,First Solar Inc,CdTe,0,470.0,442.7,2.52,,,268.0,2.61,224.3,2.46,191.1,0.0014720399999999998,-0.6210867,46.58,7.8365397879954255,2.6120904599152013,9.489784390544394e-13,3.276456142200578,4090.750784548157,-9.900761316155462,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6470A-P-B,First Solar Inc,CdTe,0,470.0,435.4,2.52,,,268.0,2.61,224.3,2.46,191.1,0.00132066,-0.6071801000000001,50.1,7.992517088762955,2.6119143906116022,1.6603496584944151e-12,3.13042879478575,4267.89554726904,-3.404778500476131,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6470A-P-B-2,First Solar Inc,Thin Film,0,470.0,446.6,2.52,,,268.0,2.724,230.55,2.548,184.493,0.0008934720000000002,-0.5215041000000001,46.99,7.458487929529736,2.732080179362448,9.990000009366039e-14,8.884468354223976,2995.1428945898833,-8.472967245414868,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6470A-P-B-I,First Solar Inc,CdTe,0,470.0,435.4,2.52,,,268.0,2.61,224.3,2.46,191.1,0.00132066,-0.6071801000000001,50.1,7.992517088762955,2.6119143906116022,1.6603496584944151e-12,3.13042879478575,4267.89554726904,-3.404778500476131,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6470A-P-I,First Solar Inc,CdTe,0,470.0,442.7,2.52,,,268.0,2.61,224.3,2.46,191.1,0.0014720399999999998,-0.6210867,46.58,7.8365397879954255,2.6120904599152013,9.489784390544394e-13,3.276456142200578,4090.750784548157,-9.900761316155462,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6470-P-B,First Solar Inc,CdTe,0,470.0,435.4,2.52,,,268.0,2.61,224.3,2.46,191.1,0.00132066,-0.6071801000000001,50.1,7.992517088762955,2.6119143906116022,1.6603496584944151e-12,3.13042879478575,4267.89554726904,-3.404778500476131,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6470-P-B-2,First Solar Inc,Thin Film,0,470.0,446.7,2.52,,,268.0,2.724,230.55,2.548,184.493,0.0008934720000000002,-0.5215041000000001,46.83,7.458487929529736,2.732080179362448,9.990000009366039e-14,8.884468354223976,2995.1428945898833,-8.472967245414868,-0.2292,N,2025.7.3,6/23/2025,2.0,first_pass +First Solar Inc FS-6475A-P,First Solar Inc,CdTe,0,475.0,447.5,2.52,,,268.0,2.61,224.8,2.48,191.5,0.0014720399999999998,-0.6224712,46.58,7.8228806024093664,2.611141884175266,8.548632019556788e-13,3.321476912556519,7591.886237425325,-10.704173096231239,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6475A-P-B,First Solar Inc,CdTe,0,475.0,440.2,2.52,,,268.0,2.61,224.8,2.48,191.5,0.00132066,-0.6085336,50.1,7.978511566562121,2.6110072564062823,1.4986472855307485e-12,3.1772268145886136,8232.821312161846,-4.244803757735603,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6475A-P-B-I,First Solar Inc,CdTe,0,475.0,440.2,2.52,,,268.0,2.61,224.8,2.48,191.5,0.00132066,-0.6085336,50.1,7.978511566562121,2.6110072564062823,1.4986472855307485e-12,3.1772268145886136,8232.821312161846,-4.244803757735603,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6475A-P-I,First Solar Inc,CdTe,0,475.0,447.5,2.52,,,268.0,2.61,224.8,2.48,191.5,0.0014720399999999998,-0.6224712,46.58,7.8228806024093664,2.611141884175266,8.548632019556788e-13,3.321476912556519,7591.886237425325,-10.704173096231239,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6475-P-B,First Solar Inc,CdTe,0,475.0,440.2,2.52,,,268.0,2.61,224.8,2.48,191.5,0.00132066,-0.6085336,50.1,7.978511566562121,2.6110072564062823,1.4986472855307485e-12,3.1772268145886136,8232.821312161846,-4.244803757735603,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6480A-P,First Solar Inc,CdTe,0,480.0,452.3,2.52,,,268.0,2.62,225.4,2.49,192.8,0.00147768,-0.6241325999999999,46.58,7.858872875679076,2.621027784598702,9.06795714944035e-13,2.9585560025702544,7541.867445699902,-10.29623403684238,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6480A-P-B,First Solar Inc,CdTe,0,480.0,444.9,2.52,,,268.0,2.62,225.4,2.49,192.8,0.00132572,-0.6101578,50.1,8.0152041428755,2.6209026669438615,1.5878795478079203e-12,2.8138390510151035,8167.196432915468,-3.8196240651543025,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6480A-P-B-I,First Solar Inc,CdTe,0,480.0,444.9,2.52,,,268.0,2.62,225.4,2.49,192.8,0.00132572,-0.6101578,50.1,8.0152041428755,2.6209026669438615,1.5878795478079203e-12,2.8138390510151035,8167.196432915468,-3.8196240651543025,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6480A-P-I,First Solar Inc,CdTe,0,480.0,452.3,2.52,,,268.0,2.62,225.4,2.49,192.8,0.00147768,-0.6241325999999999,46.58,7.858872875679076,2.621027784598702,9.06795714944035e-13,2.9585560025702544,7541.867445699902,-10.29623403684238,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6480-P-B,First Solar Inc,CdTe,0,480.0,444.9,2.52,,,268.0,2.62,225.4,2.49,192.8,0.00132572,-0.6101578,50.1,8.0152041428755,2.6209026669438615,1.5878795478079203e-12,2.8138390510151035,8167.196432915468,-3.8196240651543025,-0.2961,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6485A-P,First Solar Inc,CdTe,0,485.0,457.1,2.52,,,268.0,2.62,225.9,2.5,194.0,0.00147768,-0.6255170999999999,46.58,7.876618281042927,2.620553672391112,9.117690065399635e-13,2.6285074948079914,12438.203101269857,-10.269781101573967,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-6485A-P-I,First Solar Inc,CdTe,0,485.0,457.1,2.52,,,268.0,2.62,225.9,2.5,194.0,0.00147768,-0.6255170999999999,46.58,7.876618281042927,2.620553672391112,9.117690065399635e-13,2.6285074948079914,12438.203101269857,-10.269781101573967,-0.2723,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7505A-FT1,First Solar Inc,CdTe,0,505.0,469.4,2.8,,,268.0,3.01,223.9,2.77,182.5,0.00142975,-0.6087841,48.94,7.851525158824488,3.02149314180156,1.188142184774112e-12,6.083265539136962,1593.1787501394854,-7.407984397612413,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7505A-TR1,First Solar Inc,CdTe,0,505.0,469.4,2.8,,,268.0,3.01,223.9,2.77,182.5,0.00142975,-0.6087841,48.94,7.851525158824488,3.02149314180156,1.188142184774112e-12,6.083265539136962,1593.1787501394854,-7.407984397612413,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7510A-FT1,First Solar Inc,CdTe,0,510.0,474.1,2.8,,,268.0,3.02,224.5,2.78,183.4,0.0014345,-0.6104155,48.94,7.880536205750486,3.031151639907959,1.2271171120336875e-12,5.909239977862205,1600.2942076180316,-7.187375469257104,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7510A-TR1,First Solar Inc,CdTe,0,510.0,474.1,2.8,,,268.0,3.02,224.5,2.78,183.4,0.0014345,-0.6104155,48.94,7.880536205750486,3.031151639907959,1.2271171120336875e-12,5.909239977862205,1600.2942076180316,-7.187375469257104,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7515A-FT1,First Solar Inc,CdTe,0,515.0,478.9,2.8,,,268.0,3.03,225.0,2.8,184.3,0.0014392499999999998,-0.611775,48.94,7.894165027895034,3.039735602867732,1.219095490473577e-12,5.700264355843493,1774.086438218562,-7.275724991864677,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7515A-TR1,First Solar Inc,CdTe,0,515.0,478.9,2.8,,,268.0,3.03,225.0,2.8,184.3,0.0014392499999999998,-0.611775,48.94,7.894165027895034,3.039735602867732,1.219095490473577e-12,5.700264355843493,1774.086438218562,-7.275724991864677,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7520A-FT1,First Solar Inc,CdTe,0,520.0,483.7,2.8,,,268.0,3.04,225.6,2.81,185.2,0.001444,-0.6134063999999999,48.94,7.923101504460089,3.049433953270255,1.2584416372864006e-12,5.5296820105352396,1781.8864316083923,-7.058585183734957,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7520A-TR1,First Solar Inc,CdTe,0,520.0,483.7,2.8,,,268.0,3.04,225.6,2.81,185.2,0.001444,-0.6134063999999999,48.94,7.923101504460089,3.049433953270255,1.2584416372864006e-12,5.5296820105352396,1781.8864316083923,-7.058585183734957,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7525A-FT1,First Solar Inc,CdTe,0,525.0,488.4,2.8,,,268.0,3.04,226.1,2.82,186.0,0.001444,-0.6147659,48.94,7.935561639109507,3.0482346282640225,1.240548165469843e-12,5.383850443950095,1987.5706397359895,-7.180323584254416,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7525A-TR1,First Solar Inc,CdTe,0,525.0,488.4,2.8,,,268.0,3.04,226.1,2.82,186.0,0.001444,-0.6147659,48.94,7.935561639109507,3.0482346282640225,1.240548165469843e-12,5.383850443950095,1987.5706397359895,-7.180323584254416,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7530A-FT1,First Solar Inc,CdTe,0,530.0,493.2,2.8,,,268.0,3.05,226.7,2.84,186.9,0.00144875,-0.6163972999999999,48.94,7.950985010039145,3.057048421761058,1.2249271897902352e-12,5.217231209828202,2257.6054249454423,-7.315359469509228,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7530A-TR1,First Solar Inc,CdTe,0,530.0,493.2,2.8,,,268.0,3.05,226.7,2.84,186.9,0.00144875,-0.6163972999999999,48.94,7.950985010039145,3.057048421761058,1.2249271897902352e-12,5.217231209828202,2257.6054249454423,-7.315359469509228,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7535A-FT1,First Solar Inc,CdTe,0,535.0,498.0,2.8,,,268.0,3.06,227.2,2.85,187.8,0.0014535000000000001,-0.6177567999999999,48.94,7.978060213570974,3.066778304907954,1.271607722403819e-12,5.015632117367978,2264.2584592658527,-7.054915503739479,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7535A-TR1,First Solar Inc,CdTe,0,535.0,498.0,2.8,,,268.0,3.06,227.2,2.85,187.8,0.0014535000000000001,-0.6177567999999999,48.94,7.978060213570974,3.066778304907954,1.271607722403819e-12,5.015632117367978,2264.2584592658527,-7.054915503739479,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7540A-FT1,First Solar Inc,CdTe,0,540.0,502.7,2.8,,,268.0,3.06,227.7,2.86,188.7,0.0014535000000000001,-0.6191163,48.94,7.992631510058849,3.065701654783873,1.2630252074157642e-12,4.833816650764066,2594.2431679198753,-7.118990150536079,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7540A-TR1,First Solar Inc,CdTe,0,540.0,502.7,2.8,,,268.0,3.06,227.7,2.86,188.7,0.0014535000000000001,-0.6191163,48.94,7.992631510058849,3.065701654783873,1.2630252074157642e-12,4.833816650764066,2594.2431679198753,-7.118990150536079,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7545A-FT1,First Solar Inc,CdTe,0,545.0,507.5,2.8,,,268.0,3.07,228.2,2.88,189.6,0.00145825,-0.6204757999999999,48.94,8.006359454704235,3.0746622432357706,1.2551731555076565e-12,4.638422134117464,3054.314251248108,-7.20476911037284,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7545A-TR1,First Solar Inc,CdTe,0,545.0,507.5,2.8,,,268.0,3.07,228.2,2.88,189.6,0.00145825,-0.6204757999999999,48.94,8.006359454704235,3.0746622432357706,1.2551731555076565e-12,4.638422134117464,3054.314251248108,-7.20476911037284,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7550A-FT1,First Solar Inc,CdTe,0,550.0,512.3,2.8,,,268.0,3.08,228.8,2.89,190.4,0.001463,-0.6221072,48.94,8.032942019860302,3.0845291886692894,1.2843558059046238e-12,4.516455093686353,3071.3407461105207,-7.05440334346838,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +First Solar Inc FS-7550A-TR1,First Solar Inc,CdTe,0,550.0,512.3,2.8,,,268.0,3.08,228.8,2.89,190.4,0.001463,-0.6221072,48.94,8.032942019860302,3.0845291886692894,1.2843558059046238e-12,4.516455093686353,3071.3407461105207,-7.05440334346838,-0.2947,N,2025.7.3,6/23/2025,4.0,first_pass +Flextronics FXS-260BB-MAA1B,Flextronics,Multi-c-Si,0,252.8,229.6,1.6268799999999999,1.64,0.992,60.0,8.554,37.98,8.165,30.97,0.004918550000000001,-0.13608234,43.3,1.647318573592939,8.554002012110379,8.302826683570497e-10,0.23499260991698318,999999.6469626185,9.245058494022478,-0.4802,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-260BB-MAA1W,Flextronics,Multi-c-Si,0,252.8,229.6,1.6268799999999999,1.64,0.992,60.0,8.554,37.98,8.165,30.97,0.004918550000000001,-0.13608234,43.3,1.647318573592939,8.554002012110379,8.302826683570497e-10,0.23499260991698318,999999.6469626185,9.245058494022478,-0.4802,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-270BB-SAC1B,Flextronics,Mono-c-Si,0,270.0,246.6,1.6414199999999999,1.658,0.99,60.0,9.1,38.5,8.58,31.5,0.00455,-0.1232,44.2,1.5847388118173693,9.104446183914787,2.541156976923239e-10,0.26693834062073934,546.3425378592281,10.799185138970275,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Flextronics FXS-275BB-SAC1B,Flextronics,Mono-c-Si,0,275.0,251.3,1.6414199999999999,1.658,0.99,60.0,9.2,38.6,8.72,31.6,0.0046,-0.12352,44.2,1.5850341972040942,9.200680696717349,2.437954880421089e-10,0.2627681915538242,3551.464865339714,10.31167861980217,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Flextronics FXS-285BB-SBC1B,Flextronics,Multi-c-Si,0,278.8,254.8,1.6268799999999999,1.64,0.992,60.0,9.305,39.27,8.83,31.57,0.004699025,-0.13155450000000002,43.0,1.6515905161415054,9.338583148467805,4.405796962190571e-10,0.32766731098843516,999999.9800744223,10.350406568091886,-0.4707,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-285BB-SBC1W,Flextronics,Multi-c-Si,0,278.8,254.8,1.6268799999999999,1.64,0.992,60.0,9.305,39.27,8.83,31.57,0.004699025,-0.13155450000000002,43.0,1.6515905161415054,9.338583148467805,4.405796962190571e-10,0.32766731098843516,999999.9800744223,10.350406568091886,-0.4707,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-325BB-MAB1W,Flextronics,Multi-c-Si,0,325.0,297.6,1.8523319999999999,1.956,0.947,72.0,9.29,45.8,8.69,37.4,0.0051094999999999995,-0.15219339999999998,44.1,1.8980166648508676,9.300363540108732,3.0284161836951047e-10,0.31825032066641074,285.283395060347,7.980019156792271,-0.4373,N,2025.7.3,6/23/2025,4.0,first_pass +Flextronics FXS-325BC-MAB1W,Flextronics,Multi-c-Si,0,325.0,297.6,1.8523319999999999,1.956,0.947,72.0,9.29,45.8,8.69,37.4,0.0051094999999999995,-0.15219339999999998,44.1,1.8980166648508676,9.300363540108732,3.0284161836951047e-10,0.31825032066641074,285.283395060347,7.980019156792271,-0.4373,N,2025.7.3,6/23/2025,4.0,first_pass +Flextronics FXS-330BB-SAD1W,Flextronics,Multi-c-Si,0,330.0,300.8,1.95624,1.976,0.99,72.0,9.18,46.15,8.78,37.6,0.0045899999999999995,-0.143065,45.2,1.8738500914639673,9.180002801134057,1.84861338942408e-10,0.3050643704817737,999998.5705695399,11.398094497886245,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-335BB-SAD1W,Flextronics,Multi-c-Si,0,335.0,305.5,1.95624,1.976,0.99,72.0,9.2,46.2,8.86,37.8,0.0046,-0.14322000000000001,45.2,1.8860505102530498,9.20016091562479,2.1150533862670653e-10,0.24440096602401354,13973.055237026312,12.594776020507053,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-350BB-SBD1W,Flextronics,Multi-c-Si,0,340.2,311.4,1.960192,1.976,0.992,72.0,9.289,47.79,8.827,38.54,0.004997482,-0.15426611999999998,43.5,1.980990965353123,9.28900347930795,3.096855786887562e-10,0.3744022738594406,999999.9759110739,11.343633265302826,-0.4519,N,2025.7.3,6/23/2025,2.0,first_pass +Flextronics FXS-350BC-SBD1W,Flextronics,Multi-c-Si,0,340.2,311.4,1.960192,1.976,0.992,72.0,9.289,47.79,8.827,38.54,0.004997482,-0.15426611999999998,43.5,1.980990965353123,9.28900347930795,3.096855786887562e-10,0.3744022738594406,999999.9759110739,11.343633265302826,-0.4519,N,2025.7.3,6/23/2025,2.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-365,Freedom Forever Procurement LLC,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007562280000000001,-0.1173855,43.2,1.6140377871100615,11.220004328233308,6.755129283530156e-11,0.2453763124568138,636129.253602014,11.157966857761727,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-370,Freedom Forever Procurement LLC,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.00760946,-0.11794849999999998,43.2,1.623333945636469,11.290004300440746,6.967589700101727e-11,0.24090660789441073,632499.5698948535,11.380881482322765,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-375,Freedom Forever Procurement LLC,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.007656639999999999,-0.1185115,43.2,1.6326281749146987,11.36000427162938,7.184212125694039e-11,0.2365031656918171,629002.3785413279,11.601406904317031,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP1-BBB-395,Freedom Forever Procurement LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-395,Freedom Forever Procurement LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP1-BBB-400,Freedom Forever Procurement LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-400,Freedom Forever Procurement LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP1-BBB-405,Freedom Forever Procurement LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-405,Freedom Forever Procurement LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP1-BBB-410,Freedom Forever Procurement LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Freedom Forever Procurement LLC FF-MP-BBB-410,Freedom Forever Procurement LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt PV-GRAF-60M6-300/M,FreeVolt,Mono-c-Si,0,300.0,273.4,1.64,,,60.0,9.7,39.6,9.24,32.0,0.0043067999999999995,-0.11947320000000002,46.5,1.5633929754426412,9.70000297527509,9.689415112783683e-11,0.306672328980411,999999.8532708765,8.264933620214105,-0.4151,N,2025.7.3,6/23/2025,2.0,first_pass +FreeVolt ECP-PVGRAF-120BHC-350W,FreeVolt,Mono-c-Si,0,350.0,323.6,1.78,,,60.0,11.15,40.1,10.45,33.5,0.00687955,-0.1253125,45.4,1.5910237174140252,11.16029201385629,1.2388199462437848e-10,0.16621527068898326,180.07168889793877,5.250156657786078,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-350W,FreeVolt,Mono-c-Si,0,350.0,322.7,1.81,,,60.0,11.15,40.1,10.42,33.6,0.0061771,-0.11171860000000002,46.0,1.573145351198383,11.16207484717893,9.261981486923336e-11,0.15942448526437147,147.2137090373453,15.52492285440527,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-350W Black,FreeVolt,Mono-c-Si,0,350.0,326.3,1.83,,,40.0,11.15,40.1,10.42,33.6,0.0059095,-0.11268100000000002,44.2,1.5358103603622737,11.163295031603257,4.9785459819574983e-11,0.1673037797584847,140.31084818128528,8.965951742959888,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120BHC-355W,FreeVolt,Mono-c-Si,0,355.0,328.4,1.78,,,60.0,11.24,40.3,10.54,33.7,0.00693508,-0.12593749999999998,45.4,1.5993674020210316,11.249860885514387,1.2575596667942346e-10,0.16215590670306437,184.83456055632814,5.3078096364956355,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-355W,FreeVolt,Mono-c-Si,0,355.0,327.5,1.81,,,60.0,11.25,40.3,10.51,33.8,0.0062325,-0.1122758,46.0,1.5820674121480922,11.262132755583469,9.503872526927639e-11,0.15517143889465929,143.88147054481757,15.684015933070386,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-355W Black,FreeVolt,Mono-c-Si,0,355.0,331.1,1.83,,,40.0,11.25,40.3,10.51,33.8,0.0059625,-0.113243,44.2,1.5445127757747685,11.263361144128975,5.1100556853290356e-11,0.16303521403095028,137.27463427753585,9.118826409166019,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120BHC-360W,FreeVolt,Mono-c-Si,0,360.0,333.1,1.78,,,60.0,11.33,40.5,10.62,33.9,0.0069906099999999995,-0.12656250000000002,45.4,1.6085137204875501,11.34000623678336,1.2911096058342643e-10,0.15801823389932998,178.92307309535389,5.465899455310446,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-360W,FreeVolt,Mono-c-Si,0,360.0,332.2,1.81,,,60.0,11.35,40.5,10.59,34.0,0.0062879,-0.11283300000000002,46.0,1.591767334203999,11.36271125514716,9.860490354710674e-11,0.15083926337318254,134.68580758691422,15.951533243766043,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-360W Black,FreeVolt,Mono-c-Si,0,360.0,335.9,1.83,,,40.0,11.35,40.5,10.59,34.0,0.0060155,-0.11380500000000002,44.2,1.5539682011737326,11.363976164781905,5.304380624766523e-11,0.15870209830678145,128.88148207493782,9.375810810236858,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120BHC-365W,FreeVolt,Mono-c-Si,0,365.0,337.9,1.78,,,60.0,11.41,40.7,10.71,34.1,0.00703997,-0.1271875,45.4,1.6161070898489036,11.419061113989244,1.2951857430795875e-10,0.15436771205725558,194.3840068754955,5.427924740171898,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-365W,FreeVolt,Mono-c-Si,0,365.0,337.0,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0063322199999999995,-0.11339020000000001,46.0,1.5992338744726025,11.441735753316635,9.883882152273302e-11,0.14727260206241186,143.43568615318978,15.902164143097854,-0.3798,N,2025.7.3,6/23/2025,4.0,bootstrapping +FreeVolt ECP-PVGRAF-120HC-365W Black,FreeVolt,Mono-c-Si,0,365.0,340.7,1.83,,,40.0,11.43,40.7,10.68,34.2,0.0060579,-0.11436700000000002,44.2,1.5612619148644942,11.442953832404886,5.316537385698562e-11,0.15510751240870377,136.8613415831665,9.328389567386376,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120BHC-370W,FreeVolt,Mono-c-Si,0,370.0,342.6,1.78,,,60.0,11.5,40.9,10.79,34.3,0.0070955,-0.1278125,45.4,1.6252516759894493,11.509203377706894,1.3291880994183492e-10,0.15035429429508795,187.8738958913682,5.583665260789159,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-370W,FreeVolt,Mono-c-Si,0,370.0,341.7,1.81,,,60.0,11.52,40.9,10.76,34.4,0.006382079999999999,-0.1139474,46.0,1.6082045160669267,11.531790121453808,1.0133077111036836e-10,0.14333958942289313,140.0555627907442,16.063890655763746,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-370W Black,FreeVolt,Mono-c-Si,0,370.0,345.5,1.83,,,40.0,11.52,40.9,10.76,34.4,0.0061056,-0.114929,44.2,1.5663711906150062,11.533137654869922,5.1313585984221295e-11,0.15191721746413944,133.211473171767,8.949116749615767,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120BHC-375W,FreeVolt,Mono-c-Si,0,375.0,347.4,1.78,,,60.0,11.59,41.1,10.87,34.5,0.00715103,-0.1284375,45.4,1.6343955786653208,11.599330436057866,1.3637125044970799e-10,0.14640039183349143,181.85437165646778,5.73781088126199,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-375W,FreeVolt,Mono-c-Si,0,375.0,346.5,1.81,,,60.0,11.6,41.1,10.84,34.6,0.0064264,-0.11450460000000001,46.0,1.518831389118631,11.614566272547847,1.9981205736965716e-11,0.15974444296484103,127.21412004161442,1.7295383138266751,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-120HC-375W Black,FreeVolt,Mono-c-Si,0,375.0,350.3,1.83,,,40.0,11.6,41.1,10.84,34.6,0.006148,-0.11549100000000002,44.2,1.5780593666970166,11.612567083772003,5.5264497570365347e-11,0.14754752309515376,136.19319428997485,9.54054869590866,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72BHC-390W,FreeVolt,Mono-c-Si,0,390.0,362.3,1.95,,,72.0,10.25,48.5,9.71,40.2,0.004366500000000001,-0.1265365,45.4,1.8127241151220816,10.255277427169286,2.4404011992146344e-11,0.2793861044012475,542.633281197194,11.676601583687079,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72BHC-395W,FreeVolt,Mono-c-Si,0,395.0,367.1,1.95,,,72.0,10.29,48.7,9.76,40.5,0.004383539999999999,-0.1270583,45.4,1.8221712137434154,10.294300844472021,2.5247516698559718e-11,0.2637231459080289,630.9717181712844,11.944328870797486,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72HC-395W,FreeVolt,Mono-c-Si,0,395.0,365.4,1.91,,,72.0,10.37,48.7,9.86,40.1,0.00432429,-0.1281784,46.5,1.818309850536994,10.37220443957253,2.4137825539809313e-11,0.306989980897316,1444.124986443158,10.483863418612984,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72BHC-400W,FreeVolt,Mono-c-Si,0,400.0,371.8,1.95,,,72.0,10.33,48.9,9.81,40.8,0.00440058,-0.1275801,45.4,1.8316046053372685,10.33341025036577,2.610660155584484e-11,0.24823217369455688,751.9208677251013,12.208062661174639,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72HC-400W,FreeVolt,Mono-c-Si,0,400.0,370.2,1.91,,,72.0,10.45,49.0,9.93,40.3,0.00435765,-0.128968,46.5,1.8289600311250924,10.45270740739021,2.4114173226645323e-11,0.311947435085346,1204.0488850588736,10.408748611921862,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72BHC-405W,FreeVolt,Mono-c-Si,0,405.0,376.6,1.95,,,72.0,10.37,49.1,9.86,41.1,0.00441762,-0.12810190000000002,45.4,1.8343666740226268,10.370006261875039,2.460410518378827e-11,0.23433319723697488,388072.52043026243,11.443974996866375,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72HC-405W,FreeVolt,Mono-c-Si,0,405.0,375.0,1.91,,,72.0,10.52,49.2,10.0,40.5,0.00438684,-0.1294944,46.5,1.8369371889036124,10.522451956209933,2.4465477950495426e-11,0.307057094349389,1317.4137345099691,10.47708957243731,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72BHC-410W,FreeVolt,Mono-c-Si,0,410.0,381.4,1.95,,,72.0,10.41,49.3,9.91,41.4,0.00443466,-0.1286237,45.4,1.8504313824074166,10.411879461597461,2.787133610556779e-11,0.2177546142816728,1206.1037153092027,12.723887604395397,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72HC-410W,FreeVolt,Mono-c-Si,0,410.0,379.7,1.91,,,72.0,10.59,49.4,10.08,40.7,0.00441603,-0.1300208,46.5,1.8440511179566423,10.591351256342273,2.453848904446568e-11,0.30228053625110024,2369.0183075416217,10.438737825708738,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72HC-415W,FreeVolt,Mono-c-Si,0,415.0,384.5,1.91,,,72.0,10.66,49.6,10.15,40.9,0.00444522,-0.1305472,46.5,1.8520334981632163,10.661120877697607,2.4893484319959396e-11,0.29752850910555584,2829.6165973186226,10.507038511256006,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-72HC-420W,FreeVolt,Mono-c-Si,0,420.0,389.3,1.91,,,72.0,10.76,49.7,10.25,41.0,0.00448692,-0.13081040000000002,46.5,1.8557595887264744,10.760755793791173,2.5136835390568886e-11,0.2934094699472239,4177.179529533504,10.50857399032459,-0.3649,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144BHC-430W,FreeVolt,Mono-c-Si,0,430.0,397.8,2.14,,,72.0,11.3,48.9,10.6,40.6,0.0069721,-0.1528125,45.4,1.9326756634124558,11.310928284393885,1.1404038928125613e-10,0.2277652154600721,235.51244795616583,4.430655489224259,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144HC-430W,FreeVolt,Mono-c-Si,0,430.0,397.0,2.12,,,72.0,11.19,49.2,10.6,40.6,0.00619926,-0.13707120000000003,46.0,1.8928506328394044,11.190008032223083,5.759802713363736e-11,0.2671157720234987,372139.56764060614,11.060499713280672,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144BHC-435W,FreeVolt,Mono-c-Si,0,435.0,402.6,2.14,,,72.0,11.36,49.1,10.67,40.8,0.007009119999999999,-0.1534375,45.4,1.9158700165796523,11.360008535834739,8.418886219753073e-11,0.2285194969675685,304136.0596349038,1.8041108343847618,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144HC-435W,FreeVolt,Mono-c-Si,0,435.0,401.8,2.12,,,72.0,11.26,49.4,10.67,40.8,0.00623804,-0.1376284,46.0,1.9099027953982157,11.264092436989776,6.545271689482414e-11,0.2611435229396352,718.5147218072802,12.177878922324936,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144BHC-440W,FreeVolt,Mono-c-Si,0,440.0,407.3,2.14,,,72.0,11.45,49.3,10.74,41.0,0.00706465,-0.1540625,45.4,1.95033262365469,11.460842406593043,1.1832855635606487e-10,0.2192564944222948,231.54333048183614,4.63178500987107,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144HC-440W,FreeVolt,Mono-c-Si,0,440.0,406.6,2.12,,,72.0,11.33,49.6,10.74,41.0,0.00627682,-0.13818560000000002,46.0,1.9181787315679284,11.333833649164522,6.636503042647504e-11,0.2568537884106585,759.1079616257376,12.246040300477722,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144BHC-445W,FreeVolt,Mono-c-Si,0,445.0,412.1,2.14,,,72.0,11.52,49.5,10.81,41.2,0.00710784,-0.1546875,45.4,1.9587140876399092,11.530486946512312,1.1982241125140214e-10,0.21524693804334077,236.45060032443345,4.685119371677367,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144HC-445W,FreeVolt,Mono-c-Si,0,445.0,411.3,2.12,,,72.0,11.4,49.8,10.81,41.2,0.0063156,-0.1387428,46.0,1.9264420399273052,11.403581888556193,6.727155677440849e-11,0.25262248620091615,804.0160442371421,12.312110025583475,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144BHC-450W,FreeVolt,Mono-c-Si,0,450.0,416.9,2.14,,,72.0,11.58,49.6,10.87,41.4,0.007144859999999999,-0.15500000000000003,45.4,1.9653738386528081,11.589832309591014,1.2472102459577033e-10,0.20212800908067455,238.0562157327914,4.98011293526294,-0.3807,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-144HC-450W,FreeVolt,Mono-c-Si,0,450.0,416.1,2.12,,,72.0,11.47,50.0,10.88,41.4,0.006354380000000001,-0.1393,46.0,1.9347057015998548,11.473336757338846,6.818380812434504e-11,0.2484459122756409,854.0251872127116,12.377680209828018,-0.3798,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF550-144MT-B,FreeVolt,Mono-c-Si,0,550.0,522.5,2.58,,,24.0,12.68,52.5,12.06,45.6,0.0053256,-0.13492500000000002,43.2,1.8458210255520022,12.682715918887773,5.5680297752086675e-12,0.07692837863025526,359.16088947716634,-1.171892023297998,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF550-144MT-W,FreeVolt,Mono-c-Si,0,550.0,522.5,2.58,,,24.0,12.68,52.5,12.06,45.6,0.0053256,-0.13492500000000002,43.2,1.8458210255520022,12.682715918887773,5.5680297752086675e-12,0.07692837863025526,359.16088947716634,-1.171892023297998,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF555-144MT-B,FreeVolt,Mono-c-Si,0,555.0,527.3,2.58,,,24.0,12.76,52.6,12.13,45.8,0.0053592,-0.135182,43.2,1.851974662779487,12.762505624697335,5.830267014168659e-12,0.06591808040793334,335.69061993422156,-0.8461870319827867,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF555-144MT-W,FreeVolt,Mono-c-Si,0,555.0,527.3,2.58,,,24.0,12.76,52.6,12.13,45.8,0.0053592,-0.135182,43.2,1.851974662779487,12.762505624697335,5.830267014168659e-12,0.06591808040793334,335.69061993422156,-0.8461870319827867,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF560-144MT-B,FreeVolt,Mono-c-Si,0,560.0,532.2,2.58,,,24.0,12.84,52.7,12.2,45.9,0.0053928000000000005,-0.135439,43.2,1.8561888629582277,12.842590646853083,5.925841058569458e-12,0.06430910194857901,318.7346996073891,-0.7624408915268445,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF560-144MT-W,FreeVolt,Mono-c-Si,0,560.0,532.2,2.58,,,24.0,12.84,52.7,12.2,45.9,0.0053928000000000005,-0.135439,43.2,1.8561888629582277,12.842590646853083,5.925841058569458e-12,0.06430910194857901,318.7346996073891,-0.7624408915268445,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF565-144MT-B,FreeVolt,Mono-c-Si,0,565.0,537.0,2.58,,,24.0,12.92,52.9,12.27,46.0,0.0054264000000000005,-0.13595300000000002,43.2,1.86223261984189,12.922984259463663,5.869885733630035e-12,0.07087275342473534,306.8352424209717,-0.8884651770554809,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF565-144MT-W,FreeVolt,Mono-c-Si,0,565.0,537.0,2.58,,,24.0,12.92,52.9,12.27,46.0,0.0054264000000000005,-0.13595300000000002,43.2,1.86223261984189,12.922984259463663,5.869885733630035e-12,0.07087275342473534,306.8352424209717,-0.8884651770554809,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF570-144MT-B,FreeVolt,Mono-c-Si,0,570.0,541.9,2.58,,,24.0,13.0,53.0,12.34,46.2,0.0054600000000000004,-0.13621,43.2,1.8683840191235808,13.002694983540303,6.142643894182123e-12,0.06008548672575334,289.8389978558281,-0.5659914685990495,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF570-144MT-W,FreeVolt,Mono-c-Si,0,570.0,541.9,2.58,,,24.0,13.0,53.0,12.34,46.2,0.0054600000000000004,-0.13621,43.2,1.8683840191235808,13.002694983540303,6.142643894182123e-12,0.06008548672575334,289.8389978558281,-0.5659914685990495,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF575-144MT-B,FreeVolt,Mono-c-Si,0,575.0,546.8,2.58,,,24.0,13.08,53.2,12.41,46.3,0.0054936,-0.136724,43.2,1.8744229865922182,13.083110294294029,6.083929294390586e-12,0.06660019925564743,280.0798001256893,-0.6926181910943686,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF575-144MT-W,FreeVolt,Mono-c-Si,0,575.0,546.8,2.58,,,24.0,13.08,53.2,12.41,46.3,0.0054936,-0.136724,43.2,1.8744229865922182,13.083110294294029,6.083929294390586e-12,0.06660019925564743,280.0798001256893,-0.6926181910943686,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF580-144MT-B,FreeVolt,Mono-c-Si,0,580.0,551.6,2.58,,,24.0,13.16,53.3,12.48,46.5,0.0055272,-0.13698100000000002,43.2,1.8805732112810405,13.162768211663314,6.363971723943226e-12,0.05595873337369989,266.02623712334855,-0.37244781572071367,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF580-144MT-W,FreeVolt,Mono-c-Si,0,580.0,551.6,2.58,,,24.0,13.16,53.3,12.48,46.5,0.0055272,-0.13698100000000002,43.2,1.8805732112810405,13.162768211663314,6.363971723943226e-12,0.05595873337369989,266.02623712334855,-0.37244781572071367,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF585-144MT-B,FreeVolt,Mono-c-Si,0,585.0,556.5,2.58,,,24.0,13.24,53.4,12.55,46.6,0.005560800000000001,-0.137238,43.2,1.8847769488707893,13.242821567681217,6.4643654995324475e-12,0.054453748734233,255.5202340944343,-0.2919083475061504,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF585-144MT-W,FreeVolt,Mono-c-Si,0,585.0,556.5,2.58,,,24.0,13.24,53.4,12.55,46.6,0.005560800000000001,-0.137238,43.2,1.8847769488707893,13.242821567681217,6.4643654995324475e-12,0.054453748734233,255.5202340944343,-0.2919083475061504,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF590-144MT-B,FreeVolt,Mono-c-Si,0,590.0,561.3,2.58,,,24.0,13.32,53.6,12.62,46.8,0.005594400000000001,-0.137752,43.2,1.8927566126785016,13.322810849275646,6.5898354940168745e-12,0.0519255597159766,246.06387205257843,-0.18174099449192538,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FreeVolt ECP-PVGRAF-HC-BF590-144MT-W,FreeVolt,Mono-c-Si,0,590.0,561.3,2.58,,,24.0,13.32,53.6,12.62,46.8,0.005594400000000001,-0.137752,43.2,1.8927566126785016,13.322810849275646,6.5898354940168745e-12,0.0519255597159766,246.06387205257843,-0.18174099449192538,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-560,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,560.0,531.7,2.56,,,72.0,13.86,52.1,12.94,43.3,0.00364518,-0.1138906,44.29,1.7366564715381223,13.8901172201837,1.2572092577948307e-12,0.25012631874435665,115.1085908968991,2.3748709065657536,-0.2805,N,2025.7.3,6/23/2025,4.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-565,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,565.0,536.6,2.56,,,72.0,13.91,52.3,13.0,43.5,0.00365833,-0.1143278,44.29,1.743153966939133,13.938775785504513,1.2594960912683685e-12,0.24724895678320688,119.51830087384394,2.35485809551703,-0.2805,N,2025.7.3,6/23/2025,4.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-570,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,570.0,541.5,2.56,,,72.0,13.96,52.5,13.06,43.7,0.00367148,-0.11476499999999999,44.29,1.749651627729439,13.987462980600101,1.2617896451658063e-12,0.24439834534485663,124.23272446897279,2.3349862393711396,-0.2805,N,2025.7.3,6/23/2025,4.0,bootstrapping +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-575,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,575.0,546.3,2.56,,,72.0,14.01,52.7,13.12,43.9,0.00368463,-0.1152022,44.29,1.7561494338205146,14.036178327954923,1.264089620955206e-12,0.24157409238697028,129.2845380010017,2.315301566725752,-0.2805,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-580,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,580.0,551.2,2.56,,,72.0,14.06,52.9,13.18,44.05,0.0036977800000000003,-0.1156394,44.29,1.7617445386089692,14.085304990564886,1.2471936071985836e-12,0.24307186861387392,135.0559867434806,2.1646493549459267,-0.2805,N,2025.7.3,6/23/2025,4.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-585,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,585.0,556.0,2.56,,,72.0,14.11,53.1,13.24,44.2,0.0037109300000000003,-0.1160766,44.29,1.7673435208099393,14.134417027797188,1.230718634061426e-12,0.24455476148528965,141.3221834421114,2.015670982310623,-0.2805,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-590,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,590.0,560.9,2.56,,,72.0,14.16,53.3,13.3,44.38,0.0037240800000000003,-0.1165138,44.29,1.7734860061054956,14.183311560240268,1.2257398972238788e-12,0.24346914758874164,147.88899135983735,1.946120162286489,-0.2805,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-595,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,595.0,565.8,2.56,,,72.0,14.21,53.5,13.36,44.54,0.0037372300000000002,-0.116951,44.29,1.7792710686944575,14.23234465339602,1.21352645777143e-12,0.24408737738289735,155.22646837661753,1.8257491648034923,-0.2805,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-M10144G-600,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,600.0,570.6,2.56,,,72.0,14.26,53.7,13.42,44.71,0.00375038,-0.1173882,44.29,1.785238334329674,14.28131283258929,1.205193356769426e-12,0.24385567199869557,163.15906749156284,1.7323193146319447,-0.2805,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-610,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,610.0,578.7,2.68,,,66.0,15.63,48.38,15.04,41.24,0.0057831,-0.11514440000000001,43.98,1.6710265621456666,15.6300017295372,4.1701315378640295e-12,0.11065338733135277,999990.067738052,2.5038645637812125,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-615,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,615.0,583.6,2.68,,,66.0,15.62,48.5,14.89,41.35,0.0057794,-0.11542999999999999,43.98,1.6781760202749092,15.624622328207566,4.356517506997706e-12,0.11866064227177694,400.98390952362837,2.910557654113792,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-620,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,620.0,588.4,2.68,,,66.0,15.65,48.61,14.98,41.45,0.0057905,-0.1156918,43.98,1.6789819952165013,15.65168568536545,4.1649687718384825e-12,0.11864588482212146,1101.5152321981946,2.493860165868232,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-625,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,625.0,593.3,2.68,,,66.0,15.68,48.72,15.07,41.55,0.0058016,-0.1159536,43.98,1.6822868622298697,15.680001777188103,4.148828780519908e-12,0.11334038459024132,999998.2768170151,2.4335865802160574,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-630,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,630.0,598.1,2.68,,,66.0,15.71,48.83,15.16,41.63,0.0058127000000000005,-0.1162154,43.98,1.6886017052890634,15.710001781169083,4.340102683038523e-12,0.10154638781351744,895647.5021152989,2.7988038745518735,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +FS GREEN ENERGIES PRIVATE LIMITED FST-G12R132G-635,FS GREEN ENERGIES PRIVATE LIMITED,Mono-c-Si,1,635.0,603.0,2.68,,,66.0,15.74,48.95,15.24,41.74,0.0058238000000000005,-0.11650100000000001,43.98,1.6951766412398006,15.740001567337282,4.532058308181958e-12,0.08940857316980354,897889.695882042,3.1499030119807405,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +GAF RIAC 1000,GAF,Thin Film,0,150.0,139.2,1.086336,1.656,0.656,100.0,3.45,62.5,3.12,48.1,0.00022459500000000001,-0.17875,47.0,2.0624624837533627,3.4835264003199713,2.244640720916336e-13,2.5959806967472003,267.136743666242,-23.594676219503935,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC 294000328,GAF Energy LLC,Mono-c-Si,0,45.0,38.6,0.7,,,8.0,5.14,10.89,4.89,9.03,0.0021074,-0.028749600000000004,59.35,0.3995600063395428,5.141339825158756,7.455948069240429e-12,0.12741550270963253,488.80698437393573,6.021111277885241,-0.347,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-1,GAF Energy LLC,Mono-c-Si,0,46.0,41.4,0.7,,,8.0,5.4,10.9,5.16,9.03,0.0016902000000000002,-0.035359600000000005,43.4,0.45085549901096494,5.400000488258107,1.7091350734977386e-10,0.09035628853923744,999999.1802932431,10.589121425225285,-0.4543,Y,2025.7.3,6/23/2025,2.0,first_pass +GAF Energy LLC TLS-11,GAF Energy LLC,Mono-c-Si,0,46.0,41.4,0.7,,,8.0,5.4,10.9,5.16,9.0,0.0016740000000000001,-0.035316,43.4,0.44985613983287,5.400000522931944,1.6197627355893665e-10,0.09677326760026399,999998.9936777942,10.25288097121217,-0.454,Y,2025.7.3,6/23/2025,2.0,first_pass +GAF Energy LLC TLS-12,GAF Energy LLC,Mono-c-Si,0,47.0,40.0,0.7,,,8.0,5.4,10.9,5.16,9.12,0.0018036000000000003,-0.0330161,58.0,0.41705363565127374,5.400000503933937,2.40874525095267e-11,0.09331048727274292,999999.6525718165,1.1930517797509355,-0.3822,Y,2025.7.3,6/23/2025,2.0,first_pass +GAF Energy LLC TLS-13,GAF Energy LLC,Mono-c-Si,0,48.0,40.5,0.7,,,8.0,5.44,10.9,5.16,9.3,0.00200192,-0.0334957,54.5,0.4556637964365563,5.440539220904804,2.211668052494181e-10,0.04115920167264345,415.2400484534608,19.100906009397658,-0.4483,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-2-56,GAF Energy LLC,Mono-c-Si,0,56.0,48.1,0.7,,,8.0,6.63,10.66,6.29,8.9,0.00306306,-0.030263739999999997,55.7,0.4182304599392362,6.6316528542351465,5.622154968540151e-11,0.07674308792271109,307.8352000698592,13.584730286810096,-0.3955,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-2J-56,GAF Energy LLC,Mono-c-Si,0,56.0,48.1,0.7,,,8.0,6.63,10.66,6.29,8.9,0.00306306,-0.030263739999999997,55.7,0.4182304599392362,6.6316528542351465,5.622154968540151e-11,0.07674308792271109,307.8352000698592,13.584730286810096,-0.3955,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-2,GAF Energy LLC,Mono-c-Si,0,57.0,49.0,0.7,,,8.0,6.63,10.85,6.3,9.04,0.00306306,-0.030803149999999998,55.7,0.42488517403388726,6.63101053764911,5.3699680655722255e-11,0.08162289811636002,535.5168000495349,13.157726948837968,-0.3955,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-2J,GAF Energy LLC,Mono-c-Si,0,57.0,49.0,0.7,,,8.0,6.63,10.85,6.3,9.04,0.00306306,-0.030803149999999998,55.7,0.42488517403388726,6.63101053764911,5.3699680655722255e-11,0.08162289811636002,535.5168000495349,13.157726948837968,-0.3955,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-2-58,GAF Energy LLC,Mono-c-Si,0,58.0,49.9,0.7,,,8.0,6.63,11.04,6.31,9.2,0.00306306,-0.03134256,55.7,0.43202578102276085,6.630366888686971,5.28542223862672e-11,0.08282326209222383,1496.6894611496057,13.006175681896789,-0.3955,Y,2025.7.3,6/23/2025,4.0,first_pass +GAF Energy LLC TLS-2J-58,GAF Energy LLC,Mono-c-Si,0,58.0,49.9,0.7,,,8.0,6.63,11.04,6.31,9.2,0.00306306,-0.03134256,55.7,0.43202578102276085,6.630366888686971,5.28542223862672e-11,0.08282326209222383,1496.6894611496057,13.006175681896789,-0.3955,Y,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1680-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,560.0,532.3,2.567328,,,72.0,14.17,50.44,13.41,41.77,0.005072859999999999,-0.11560847999999999,44.08,1.6855834606927547,14.185098712797878,1.4097060236324479e-12,0.2467283686137566,231.5522542418557,-1.8373917499277226,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1680N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,560.0,531.0,2.57,,,72.0,14.17,50.44,13.42,41.77,0.00464776,-0.11929059999999998,45.12,1.675228895685632,14.18456098284829,1.1723810811412816e-12,0.24839397354917192,241.7242465144174,-6.296767902096497,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1695-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,565.0,537.2,2.567328,,,72.0,14.24,50.59,13.48,41.92,0.00509792,-0.11595227999999999,44.08,1.6908669836010821,14.254752454547418,1.4238588713529505e-12,0.24407431534773147,235.59593028158622,-1.7968679140171122,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1695N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,565.0,535.9,2.57,,,72.0,14.24,50.59,13.49,41.92,0.004670720000000001,-0.11964535,45.12,1.6804824170451198,14.254220656574685,1.1842331582009187e-12,0.24573887772492795,246.07314017072028,-6.257450328806627,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1710-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,570.0,542.0,2.567328,,,72.0,14.31,50.74,13.55,42.07,0.00512298,-0.11629608000000001,44.08,1.6961508919005976,14.324411297323197,1.438081850479732e-12,0.24144772817268795,239.7505870021969,-1.7565335373403297,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1710N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,570.0,540.7,2.57,,,72.0,14.31,50.74,13.56,42.07,0.00469368,-0.12000010000000001,45.12,1.6857363190563484,14.323885357361474,1.1961446918238973e-12,0.24311123995525813,250.5460789474907,-6.218316927841343,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1725-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,575.0,546.9,2.567328,,,72.0,14.38,50.89,13.62,42.22,0.00514804,-0.11663988,44.08,1.7014351786880129,14.394075176906613,1.452374768464187e-12,0.23884818366618968,244.02086067089897,-1.7163878007398832,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1725N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,575.0,545.6,2.57,,,72.0,14.38,50.89,13.63,42.22,0.004716640000000001,-0.12035485,45.12,1.69099059816743,14.393555024742524,1.208115590341219e-12,0.24051063672046197,255.1484061260614,-6.179366447944763,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1740-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,580.0,551.7,2.567328,,,72.0,14.45,51.04,13.69,42.37,0.005173099999999999,-0.11698367999999998,44.08,1.7067198346439671,14.463744027868836,1.4667373696005836e-12,0.2362752674493683,248.41172104338338,-1.6764302527888961,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1740N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,580.0,550.4,2.57,,,72.0,14.45,51.04,13.7,42.37,0.0047396,-0.12070959999999999,45.12,1.6962452394725123,14.463229588696413,1.2201455243932235e-12,0.23793665515727408,259.8859839018323,-6.140599804500926,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1755-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,585.0,556.6,2.567328,,,72.0,14.52,51.19,13.76,42.52,0.005198159999999999,-0.11732748,44.08,1.7120048687871743,14.53341780191693,1.4811698443944886e-12,0.23372857071305958,252.92807425611187,-1.6366576385776461,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1755N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,585.0,555.3,2.57,,,72.0,14.52,51.19,13.77,42.52,0.00476256,-0.12106435,45.12,1.7015002355773738,14.53290898804029,1.2322343181183759e-12,0.23538888890683957,264.7648767139634,-6.102015133624506,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1770-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,590.0,561.5,2.567328,,,72.0,14.59,51.34,13.83,42.67,0.00522322,-0.11767128000000002,44.08,1.7172902598766435,14.603096424692334,1.4956716376150144e-12,0.23120769778586012,257.575666079052,-1.5970716887274974,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1770N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,590.0,560.1,2.57,,,72.0,14.59,51.34,13.84,42.67,0.004785520000000001,-0.12141910000000002,45.12,1.7067556098224357,14.602593188077893,1.2443824270865566e-12,0.23286693615712306,269.79098329896215,-6.0636085874581855,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1785-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,595.0,566.3,2.567328,,,72.0,14.66,51.49,13.9,42.82,0.00524828,-0.11801508,44.08,1.7225760136672033,14.672779846724676,1.510242855281333e-12,0.22871225663581687,262.3600850252801,-1.5576696404311083,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1785N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,595.0,565.0,2.57,,,72.0,14.66,51.49,13.91,42.82,0.00480848,-0.12177385,45.12,1.7120113204848648,14.672282098679206,1.25658895513214e-12,0.2303704124385058,274.9717565822943,-6.025383996901732,-0.2752,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2G1800-HAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,600.0,571.2,2.567328,,,72.0,14.72,51.64,13.96,42.97,0.00526976,-0.11835887999999999,44.08,1.7278895966748795,14.732502598821037,1.5245069052928706e-12,0.22639532517136565,266.54771796452536,-1.514718594266624,-0.2778,N,2025.7.3,6/23/2025,4.0,first_pass +Gautam Solar Pvt Ltd G2X1800N-UHAD,Gautam Solar Pvt Ltd,Mono-c-Si,1,600.0,569.9,2.57,,,72.0,14.72,51.64,13.97,42.97,0.004828160000000001,-0.12212859999999999,45.12,1.7172942678494099,14.732010335287061,1.2685361919203851e-12,0.2280536448990226,279.5050741571334,-5.9837968217120725,-0.2752,N,2025.7.3,6/23/2025,2.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60255,GCL System Integration Technology Co Ltd,Multi-c-Si,0,255.0,230.6,1.6268799999999999,1.64,0.992,60.0,8.98,37.7,8.26,30.4,0.004137984000000001,-0.11972389000000003,46.4,1.5365354823535455,9.007157480379687,1.9140348759443795e-10,0.3314372348692122,109.59435308829603,9.386475123416533,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60260,GCL System Integration Technology Co Ltd,Multi-c-Si,0,260.0,235.3,1.6268799999999999,1.64,0.992,60.0,9.09,37.9,8.38,30.6,0.004188672,-0.12035903,46.4,1.5439481677044344,9.115123400097838,1.9197521007087992e-10,0.3238191014989163,117.16231675235743,9.29783472553384,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60B260,GCL System Integration Technology Co Ltd,Multi-c-Si,0,260.0,234.2,1.63,,,1.0,9.09,37.9,8.44,30.8,0.0060903,-0.12886,46.62,1.599936498944141,9.105464013116965,4.5762990251347677e-10,0.28239201030636907,165.9946649251596,9.166845379912841,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60265,GCL System Integration Technology Co Ltd,Multi-c-Si,0,265.0,239.9,1.6268799999999999,1.64,0.992,60.0,9.2,38.1,8.5,30.8,0.00423936,-0.12099417000000001,46.4,1.551391723136955,9.22315466605553,1.9262261392584566e-10,0.31640375131519294,125.71611436842505,9.214078153331396,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60B265,GCL System Integration Technology Co Ltd,Multi-c-Si,0,265.0,238.9,1.63,,,1.0,9.2,38.1,8.55,31.0,0.006164,-0.12954000000000002,46.62,1.6087122515310153,9.214730372600236,4.658916575360668e-10,0.27540046886441305,172.00409264351944,9.216063653278129,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60270,GCL System Integration Technology Co Ltd,Multi-c-Si,0,270.0,244.6,1.6268799999999999,1.64,0.992,60.0,9.29,38.3,8.61,31.0,0.004280832,-0.12162931,46.4,1.5580449613057674,9.310339435207734,1.906739115902887e-10,0.3099041696607552,141.54817236039486,9.028062203086192,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60B270,GCL System Integration Technology Co Ltd,Multi-c-Si,0,270.0,243.5,1.63,,,1.0,9.29,38.3,8.65,31.2,0.0062243,-0.13022,46.62,1.6166181920474596,9.30323823208207,4.677455222082463e-10,0.2692732071018633,188.96393447999827,9.159060692304239,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60275,GCL System Integration Technology Co Ltd,Mono-c-Si,0,275.0,247.6,1.63,,,60.0,9.38,38.5,8.76,31.4,0.00467124,-0.12612600000000002,47.5,1.583210326350612,9.392256743008057,2.530060996761935e-10,0.2730088895549563,208.93181786475105,7.948174603151385,-0.4348,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60275,GCL System Integration Technology Co Ltd,Multi-c-Si,0,275.0,249.3,1.6268799999999999,1.64,0.992,60.0,9.38,38.5,8.7,31.2,0.004322304000000001,-0.12226445000000001,46.4,1.5666418826679323,9.399611227632978,1.9406695238363366e-10,0.30341897758389047,145.12452805845487,9.095994125345758,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60280,GCL System Integration Technology Co Ltd,Mono-c-Si,0,280.0,252.2,1.63,,,60.0,9.46,38.7,8.86,31.6,0.00471108,-0.1267812,47.5,1.590075045730398,9.47000515684112,2.5073220640137183e-10,0.2674687839013115,252.89508038839875,7.785607391949624,-0.4348,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60280,GCL System Integration Technology Co Ltd,Multi-c-Si,0,280.0,253.7,1.63,,,60.0,9.46,38.7,8.86,31.6,0.005250300000000001,-0.1433835,46.3,1.6076868225373324,9.4694601071224,3.2753591893315374e-10,0.2633103190659995,263.3073712559603,-2.763034341127524,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60285,GCL System Integration Technology Co Ltd,Mono-c-Si,0,285.0,256.9,1.63,,,60.0,9.54,38.9,8.96,31.8,0.00475092,-0.1274364,47.5,1.5969698965886554,9.547833397194296,2.4860263714970345e-10,0.26204091153390563,319.12981485266727,7.628342483424104,-0.4348,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60285,GCL System Integration Technology Co Ltd,Multi-c-Si,0,285.0,258.4,1.63,,,60.0,9.54,38.9,8.96,31.8,0.0052947,-0.14412450000000002,46.3,1.61462148107101,9.547324568304616,3.2464916070448056e-10,0.2579184225982344,335.9299819579573,-2.9071275770086653,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60290,GCL System Integration Technology Co Ltd,Mono-c-Si,0,290.0,261.5,1.63,,,60.0,9.63,39.1,9.06,32.0,0.004795740000000001,-0.1280916,47.5,1.6047703870811476,9.636536471890158,2.498661265944267e-10,0.25635605827500674,377.68221569335367,7.584831687736228,-0.4348,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/60290,GCL System Integration Technology Co Ltd,Multi-c-Si,0,290.0,263.1,1.63,,,60.0,9.63,39.1,9.06,32.0,0.00534465,-0.1448655,46.3,1.6224998779153916,9.636050108227884,3.262813987372137e-10,0.25225903462042154,401.5225623053209,-2.946564520422928,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60295,GCL System Integration Technology Co Ltd,Mono-c-Si,0,295.0,266.2,1.63,,,60.0,9.69,39.3,9.16,32.2,0.00482562,-0.1287468,47.5,1.609977584113576,9.692937611746952,2.4159161913853256e-10,0.25186723325629157,830.8089090359766,7.221784986541848,-0.4348,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60300,GCL System Integration Technology Co Ltd,Mono-c-Si,0,300.0,273.5,1.63,,,60.0,9.78,39.5,9.26,32.4,0.00360882,-0.116051,46.6,1.5528299675697812,9.783359957201911,8.72652891415876e-11,0.26124689070553536,760.4248254159243,10.298118371296042,-0.4115,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72300,GCL System Integration Technology Co Ltd,Multi-c-Si,0,300.0,271.2,1.9403519999999999,1.956,0.992,72.0,8.82,45.0,8.14,36.4,0.0040642560000000005,-0.14290650000000002,46.4,1.8340621429743946,8.842963191695107,1.8868250444101273e-10,0.38654096744927247,148.46766642460793,9.407825220195155,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60305,GCL System Integration Technology Co Ltd,Mono-c-Si,0,305.0,278.2,1.63,,,60.0,9.87,39.7,9.36,32.6,0.00364203,-0.11663860000000001,46.6,1.5603822491750814,9.87216262341363,8.777755886996969e-11,0.2558090891676645,1167.4876434800458,10.262406389238171,-0.4115,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72305,GCL System Integration Technology Co Ltd,Multi-c-Si,0,305.0,275.9,1.9403519999999999,1.956,0.992,72.0,8.91,45.2,8.22,36.6,0.004105728,-0.14354164000000003,46.4,1.8436863581211633,8.933231966288629,1.942707890867463e-10,0.37883182670157,145.29083254694063,9.57754691594144,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60310,GCL System Integration Technology Co Ltd,Mono-c-Si,0,310.0,282.9,1.63,,,60.0,9.96,39.9,9.46,32.8,0.0036752400000000006,-0.1172262,46.6,1.5679459649053868,9.961007965285138,8.830300915284962e-11,0.25048247605104473,2475.091505680345,10.228559317297703,-0.4115,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72310,GCL System Integration Technology Co Ltd,Multi-c-Si,0,310.0,280.5,1.9403519999999999,1.956,0.992,72.0,8.99,45.4,8.31,36.8,0.0041425920000000005,-0.14417678,46.4,1.8510043329776154,9.01155466253237,1.9427661600756812e-10,0.371880535358269,155.1036190524786,9.492143661238813,-0.42929,N,2025.7.3,6/23/2025,4.0,bootstrapping +GCL System Integration Technology Co Ltd GCL-M6/60315,GCL System Integration Technology Co Ltd,Mono-c-Si,0,315.0,287.6,1.63,,,60.0,10.04,40.1,9.55,33.0,0.0037047599999999997,-0.11781380000000001,46.6,1.5756942732296686,10.040003305157622,8.898732288828716e-11,0.2454770942404831,745755.8942586741,10.220487472033632,-0.4115,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72315,GCL System Integration Technology Co Ltd,Multi-c-Si,0,315.0,285.2,1.9403519999999999,1.956,0.992,72.0,9.08,45.6,8.39,37.0,0.004184064,-0.14481192,46.4,1.8606285461552132,9.10182475751324,1.9994669115125975e-10,0.3644689107758569,151.63411813909227,9.66000303765577,-0.42929,N,2025.7.3,6/23/2025,4.0,bootstrapping +GCL System Integration Technology Co Ltd GCL-P6/72B315,GCL System Integration Technology Co Ltd,Multi-c-Si,0,315.0,283.9,1.94,,,1.0,9.08,45.6,8.47,37.2,0.006083600000000001,-0.15504,46.62,1.9244340126460762,9.091401669001753,4.5634330187154837e-10,0.320829000322202,255.50011455855426,9.137234755683266,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/60320,GCL System Integration Technology Co Ltd,Mono-c-Si,0,320.0,292.3,1.63,,,60.0,10.12,40.3,9.64,33.2,0.00373428,-0.11840139999999999,46.6,1.5853294326571923,10.120002380259976,9.229103791294942e-11,0.2351708598915908,999999.9065480906,10.473459218878492,-0.4115,N,2025.7.3,6/23/2025,2.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72320,GCL System Integration Technology Co Ltd,Multi-c-Si,0,320.0,289.8,1.9403519999999999,1.956,0.992,72.0,9.17,45.8,8.48,37.2,0.004225536,-0.14544706,46.4,1.8690646108564357,9.191120401388007,2.028314329205968e-10,0.35730983675756967,155.13584675941308,9.69683911141327,-0.42929,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72B320,GCL System Integration Technology Co Ltd,Multi-c-Si,0,320.0,288.6,1.94,,,1.0,9.17,45.8,8.56,37.4,0.006143900000000001,-0.15572,46.62,1.933243085074738,9.180880047617048,4.632925189788362e-10,0.3140902350286645,264.72383008134653,9.181587891041731,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72325,GCL System Integration Technology Co Ltd,Mono-c-Si,0,325.0,293.7,1.94,,,72.0,9.24,46.0,8.64,37.6,0.00453684,-0.15101799999999999,46.83,1.8865840340897326,9.2510307443267,2.337902704060613e-10,0.3214661490635745,269.27896888540994,7.168173959588826,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72325,GCL System Integration Technology Co Ltd,Multi-c-Si,0,325.0,294.7,1.94,1.956,0.992,72.0,9.24,46.0,8.64,37.6,0.005211360000000001,-0.139564,46.5,1.8746128506248858,9.251349740539183,2.0001308305861215e-10,0.3243815862254138,264.0841030211135,14.488583657369102,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72B325,GCL System Integration Technology Co Ltd,Multi-c-Si,0,325.0,293.2,1.94,,,1.0,9.24,46.0,8.64,37.6,0.006190800000000001,-0.1564,46.62,1.9409979290100938,9.24963467413576,4.638183231517124e-10,0.3083039800445362,295.67468430188677,9.118826637711967,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72330,GCL System Integration Technology Co Ltd,Mono-c-Si,0,330.0,298.3,1.94,,,72.0,9.33,46.2,8.73,37.8,0.00458103,-0.1516746,46.83,1.89515285744374,9.340528228011287,2.373463924978092e-10,0.31491565650112663,279.0748184732187,7.212725934013477,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H330,GCL System Integration Technology Co Ltd,Mono-c-Si,0,330.0,301.4,1.94,,,72.0,9.33,46.2,8.73,37.8,0.00340545,-0.1382766,45.5,1.8332656972448553,9.342192583221669,1.0404770315352895e-10,0.32991812918551433,252.45972931884364,10.27222722590319,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72330,GCL System Integration Technology Co Ltd,Multi-c-Si,0,330.0,299.4,1.94,,,72.0,9.33,46.2,8.73,37.8,0.00526212,-0.1401708,46.5,1.8831192922404976,9.34084279350998,2.0304031508653373e-10,0.31781777918418086,273.4756581962508,14.535568042339174,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72B330,GCL System Integration Technology Co Ltd,Multi-c-Si,0,330.0,297.9,1.94,,,1.0,9.33,46.2,8.73,37.8,0.006251100000000001,-0.15708000000000003,46.62,1.9498246437019346,9.339153278127647,4.708726792795358e-10,0.3018197471376051,307.6470138611175,9.164601675231715,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H330,GCL System Integration Technology Co Ltd,Multi-c-Si,0,330.0,302.4,1.94,,,72.0,9.33,46.2,8.73,37.8,0.0034241100000000006,-0.133287,45.9,1.7886183774328661,9.343466054260013,5.5398153523425465e-11,0.34086264791409154,236.16781180098053,8.770550575954852,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72335,GCL System Integration Technology Co Ltd,Mono-c-Si,0,335.0,303.0,1.94,,,72.0,9.41,46.4,8.82,38.0,0.00462031,-0.15233119999999997,46.83,1.902652090522628,9.419250042293012,2.376899386698534e-10,0.3089592357591231,314.3019875697965,7.145397734413668,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H335,GCL System Integration Technology Co Ltd,Mono-c-Si,0,335.0,306.1,1.94,,,72.0,9.41,46.4,8.82,38.0,0.00343465,-0.1388752,45.5,1.8405387603761274,9.420852033669437,1.0419282776593215e-10,0.32386810720114095,280.8320559058834,10.202165675518733,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72335,GCL System Integration Technology Co Ltd,Multi-c-Si,0,335.0,304.1,1.94,,,72.0,9.41,46.4,8.82,38.0,0.00530724,-0.1407776,46.5,1.8905861951802614,9.41955219750777,2.0336272796105578e-10,0.3118404721510897,307.1982761179627,14.464864007542493,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72B335,GCL System Integration Technology Co Ltd,Multi-c-Si,0,335.0,302.5,1.94,,,1.0,9.41,46.4,8.82,38.0,0.006304700000000001,-0.15776,46.62,1.9575302197098559,9.41792993598169,4.716183542366098e-10,0.2959434464105567,351.17917299036503,9.09742061764417,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H335,GCL System Integration Technology Co Ltd,Multi-c-Si,0,335.0,307.1,1.94,,,72.0,9.41,46.4,8.82,38.0,0.0034534700000000006,-0.13386399999999998,45.9,1.795728775772718,9.422080416633113,5.5474226874423676e-11,0.334744184308818,260.7478648247717,8.701028102683575,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72340,GCL System Integration Technology Co Ltd,Mono-c-Si,0,340.0,307.7,1.94,,,72.0,9.49,46.6,8.9,38.2,0.00465959,-0.1529878,46.83,1.9113086082466846,9.498828246494076,2.4124433471155066e-10,0.30297174904783813,325.6821357822473,7.198721658464533,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H340,GCL System Integration Technology Co Ltd,Mono-c-Si,0,340.0,310.8,1.94,,,72.0,9.49,46.6,8.9,38.2,0.0034638499999999997,-0.1394738,45.5,1.8488943207238127,9.500407814710531,1.057451979154526e-10,0.31782701357495147,289.7994025342569,10.256231691678138,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H340,GCL System Integration Technology Co Ltd,Multi-c-Si,0,340.0,316.3,2.01,,,72.0,9.4,46.65,8.81,38.61,0.0043428,-0.13197284999999997,44.2,1.7551146989237554,9.412257969119926,2.6355641294872483e-11,0.2984726474995844,228.8831765553711,4.307172512991786,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72340,GCL System Integration Technology Co Ltd,Multi-c-Si,0,340.0,311.2,1.94,,,72.0,9.49,46.6,8.9,38.2,0.00390988,-0.137936,45.4,1.8499539103488603,9.500380023495486,1.0728596145383304e-10,0.3175732213988607,290.343273315094,11.563499053360049,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72B340,GCL System Integration Technology Co Ltd,Multi-c-Si,0,340.0,307.2,1.94,,,1.0,9.49,46.6,8.9,38.2,0.0063583,-0.15844000000000003,46.62,1.9664487598694462,9.497528525480037,4.786640289440782e-10,0.29000367144409644,365.5610283774373,9.152025249931452,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H340,GCL System Integration Technology Co Ltd,Multi-c-Si,0,340.0,311.8,1.94,,,72.0,9.49,46.6,8.9,38.2,0.00348283,-0.134441,45.9,1.8038723739546068,9.501620254689037,5.630195185614669e-11,0.32866274482559127,268.41146458650826,8.754561888161868,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72345,GCL System Integration Technology Co Ltd,Mono-c-Si,0,345.0,312.3,1.94,,,72.0,9.57,46.8,8.99,38.4,0.00469887,-0.1536444,46.83,1.9188347542275155,9.577612985516526,2.416483394274025e-10,0.2972379818384511,373.646808684506,7.134730148400545,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H345,GCL System Integration Technology Co Ltd,Mono-c-Si,0,345.0,315.5,1.94,,,72.0,9.57,46.8,8.99,38.4,0.00349305,-0.14007239999999999,45.5,1.856192694810411,9.579130546868708,1.0591700653908595e-10,0.31200329872640464,327.02002888273546,10.189636573127222,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H345,GCL System Integration Technology Co Ltd,Multi-c-Si,0,345.0,321.1,2.01,,,72.0,9.49,46.88,8.88,38.84,0.004384379999999999,-0.13262352,44.2,1.7661363522182032,9.503309466483397,2.7518192634919135e-11,0.2917772706575058,208.04487712273786,4.598212860745756,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72345,GCL System Integration Technology Co Ltd,Multi-c-Si,0,345.0,315.9,1.94,,,72.0,9.61,47.3,8.87,38.9,0.00395932,-0.140008,45.4,1.8968841885890835,9.631605106196858,1.3740516104332396e-10,0.29990786249174345,133.39969716480638,13.759889067702334,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72B345,GCL System Integration Technology Co Ltd,Multi-c-Si,0,345.0,311.8,1.94,,,1.0,9.57,46.8,8.99,38.4,0.006411900000000001,-0.15912,46.62,1.9741823771399998,9.576367821594976,4.795274175003824e-10,0.284346936412177,427.3362118645991,9.088178332381263,-0.443,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H345,GCL System Integration Technology Co Ltd,Multi-c-Si,0,345.0,316.5,1.94,,,72.0,9.61,47.3,8.87,38.9,0.00352687,-0.13646049999999998,45.9,1.8492838482360492,9.633257011603524,7.223150836079748e-11,0.31147129870975154,128.70265833121795,10.91326955764562,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72350,GCL System Integration Technology Co Ltd,Mono-c-Si,0,350.0,317.0,1.94,,,72.0,9.65,47.0,9.07,38.6,0.00473815,-0.154301,46.83,1.9275026261663206,9.657226432277339,2.4524573695661553e-10,0.2914628543270946,389.2123716123772,7.188775510726491,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H350,GCL System Integration Technology Co Ltd,Mono-c-Si,0,350.0,320.2,1.94,,,72.0,9.65,47.0,9.07,38.6,0.0035222499999999998,-0.14067100000000002,45.5,1.8645589586808253,9.658721559079806,1.0748818356896716e-10,0.30617698665838855,338.7706298058786,10.244469683141272,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H350,GCL System Integration Technology Co Ltd,Multi-c-Si,0,350.0,325.8,2.01,,,72.0,9.58,47.1,8.95,39.11,0.00442596,-0.1332459,44.2,1.7779384982511484,9.594050198940446,2.921415427311042e-11,0.27889055879417096,190.15898515531256,5.032336786099057,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72350,GCL System Integration Technology Co Ltd,Multi-c-Si,0,350.0,320.6,1.94,,,72.0,9.68,47.6,8.93,39.2,0.00398816,-0.140896,45.4,1.9108941184083226,9.701666920828089,1.419187859174181e-10,0.29257174748446885,130.71052417766924,13.992292003081607,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H350,GCL System Integration Technology Co Ltd,Multi-c-Si,0,350.0,321.2,1.94,,,72.0,9.68,47.6,8.93,39.2,0.00355256,-0.137326,45.9,1.8629064504705741,9.703328501919156,7.461756084046902e-11,0.3041641737142646,126.21081491147518,11.141469671256903,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72355,GCL System Integration Technology Co Ltd,Mono-c-Si,0,355.0,321.7,1.94,,,72.0,9.73,47.2,9.16,38.8,0.00477743,-0.1549576,46.83,1.9350541253162636,9.736071721633676,2.457070513714052e-10,0.28593977290427725,458.2216575952645,7.127893008377547,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H355,GCL System Integration Technology Co Ltd,Mono-c-Si,0,355.0,324.9,1.94,,,72.0,9.73,47.2,9.16,38.8,0.0035514500000000003,-0.14126960000000002,45.5,1.8718811763229284,9.737505172393124,1.0768527851431586e-10,0.3005673926897706,389.66738348907177,10.181104042853244,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H355,GCL System Integration Technology Co Ltd,Multi-c-Si,0,355.0,330.6,2.01,,,72.0,9.67,47.3,9.01,39.4,0.00446754,-0.13381169999999998,44.2,1.790879970282575,9.685144693327821,3.182655192143007e-11,0.2612333606414334,166.79945636202712,5.694158848415406,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72355,GCL System Integration Technology Co Ltd,Multi-c-Si,0,355.0,325.3,1.94,,,72.0,9.74,47.9,8.99,39.49,0.00401288,-0.141784,45.4,1.9235714426748944,9.761072528760394,1.4404784606612037e-10,0.2870952487167005,132.69920363955046,14.070596451887063,-0.4125,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H355,GCL System Integration Technology Co Ltd,Multi-c-Si,0,355.0,325.9,1.94,,,72.0,9.74,47.9,8.99,39.49,0.0035745800000000004,-0.1381915,45.9,1.8752536409986211,9.762715898724812,7.574088119978957e-11,0.29869760586886196,128.07394256051342,11.218182987156867,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H360,GCL System Integration Technology Co Ltd,Mono-c-Si,0,360.0,335.7,2.01,,,72.0,9.63,47.52,9.07,39.7,0.0033897600000000008,-0.13395888,43.8,1.7766023273632063,9.638359044039143,2.292196038759773e-11,0.2540170799851117,292.63926456673624,3.4336033127221666,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72GDF360,GCL System Integration Technology Co Ltd,Mono-c-Si,0,360.0,336.9,2.01,,,72.0,9.72,47.73,9.25,38.92,0.004490640000000001,-0.13082793,42.4,1.7888625582973827,9.720008410353536,2.511428389634854e-11,0.3647556236547169,421562.6477257438,6.893912155912961,-0.3679,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H360,GCL System Integration Technology Co Ltd,Mono-c-Si,0,360.0,329.6,1.94,,,72.0,9.81,47.4,9.25,39.0,0.00358065,-0.1418682,45.5,1.8792191428997564,9.816324647993998,1.079014856475327e-10,0.295061199622579,457.6619208021424,10.119996225195221,-0.4155,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H360,GCL System Integration Technology Co Ltd,Multi-c-Si,0,360.0,335.4,2.01,,,72.0,9.76,47.5,9.07,39.7,0.00450912,-0.1343775,44.2,1.8040892239767397,9.77591401584562,3.4766545707501914e-11,0.242525828150898,148.74008671025737,6.383822497906082,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P6/72H360,GCL System Integration Technology Co Ltd,Multi-c-Si,0,360.0,330.6,1.94,,,72.0,9.8,48.2,9.05,39.78,0.0035966000000000006,-0.13905700000000001,45.9,1.8875990777772325,9.822116603223867,7.68676013158753e-11,0.2933051332536004,129.96527145711718,11.293727877679407,-0.3941,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72DH365,GCL System Integration Technology Co Ltd,Mono-c-Si,1,365.0,339.0,2.01,,,72.0,9.67,47.73,9.13,40.0,0.00316209,-0.14180583,43.4,1.8460808933453519,9.67546352965369,5.644813898778755e-11,0.22401081509685086,396.4808043313314,5.487019692187924,-0.3884,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72GDF365,GCL System Integration Technology Co Ltd,Mono-c-Si,0,365.0,338.6,2.04,,,72.0,9.72,47.89,9.22,39.59,0.005832,-0.14295164999999999,43.72,1.8795424648565593,9.722298981197019,8.323770118605048e-11,0.28215796449069797,1192.9526625029955,7.9047766862490585,-0.3861,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H365,GCL System Integration Technology Co Ltd,Mono-c-Si,0,365.0,340.5,2.01,,,72.0,9.67,47.73,9.13,40.0,0.0034038400000000004,-0.13455087,43.8,1.7851560149106396,9.676610164442943,2.332088949789237e-11,0.23872932792702212,349.23679132395455,3.533826707176238,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72DH365,GCL System Integration Technology Co Ltd,Mono-c-Si,0,365.0,337.8,1.98,,,72.0,9.8,47.93,9.33,39.13,0.0031948,-0.1481037,43.9,1.8444344904616674,9.800004473701804,5.076020585736221e-11,0.3466503707374023,759410.976131973,0.3967532086099479,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72GDF365,GCL System Integration Technology Co Ltd,Mono-c-Si,0,365.0,341.7,2.01,,,72.0,9.8,47.93,9.33,39.13,0.0045276,-0.13137613,42.4,1.797817999678746,9.800132944774417,2.5871335959190375e-11,0.35733559592761915,26340.95594950634,7.080594909960745,-0.3679,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H365,GCL System Integration Technology Co Ltd,Mono-c-Si,0,365.0,340.3,1.98,,,72.0,9.89,47.6,9.31,39.2,0.0031153500000000002,-0.12347440000000001,44.3,1.7435923370855988,9.901279323867358,1.3553217510366383e-11,0.3233486510728614,283.5203833025663,7.589439202909405,-0.3533,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H365,GCL System Integration Technology Co Ltd,Multi-c-Si,0,365.0,340.1,2.01,,,72.0,9.85,47.7,9.13,40.0,0.0045507,-0.13494330000000002,44.2,1.8173262380181603,9.866417258637721,3.794659944228247e-11,0.22405424503857976,134.42770041032642,7.071106601333273,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72DH370,GCL System Integration Technology Co Ltd,Mono-c-Si,1,370.0,343.7,2.01,,,72.0,9.71,47.93,9.18,40.3,0.00317517,-0.14240002999999998,43.4,1.8557869545016326,9.714537399551176,5.833248690746208e-11,0.20760957920934353,444.28290748091706,5.7262842329563695,-0.3884,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72GDF370,GCL System Integration Technology Co Ltd,Mono-c-Si,0,370.0,343.3,2.04,,,72.0,9.8,48.09,9.3,39.79,0.00588,-0.14354865,43.72,1.8878542339465627,9.802028324173252,8.448462291786945e-11,0.2767483019913759,1337.1303055860997,7.961492909358797,-0.3861,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H370,GCL System Integration Technology Co Ltd,Mono-c-Si,0,370.0,345.2,2.01,,,72.0,9.71,47.93,9.18,40.3,0.0034179200000000005,-0.13511467,43.8,1.7944855060041878,9.715592152904547,2.410184579841825e-11,0.22236872419490097,386.11248710040593,3.7704150862218797,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72DH370,GCL System Integration Technology Co Ltd,Mono-c-Si,0,370.0,342.5,1.98,,,72.0,9.88,48.13,9.41,39.32,0.00322088,-0.1487217,43.9,1.8530362243025469,9.88000451726882,5.182845213877948e-11,0.34187045852651793,747770.6933020266,0.4993111315408409,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72GDF370,GCL System Integration Technology Co Ltd,Mono-c-Si,0,370.0,346.5,2.01,,,72.0,9.88,48.13,9.41,39.32,0.0045645600000000005,-0.13192433000000003,42.4,1.805930299942636,9.880004657377691,2.632301505390449e-11,0.3525742414748256,747962.4496219704,7.159515554015156,-0.3679,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H370,GCL System Integration Technology Co Ltd,Mono-c-Si,0,370.0,345.1,1.98,,,72.0,9.97,47.8,9.39,39.41,0.00314055,-0.1239932,44.3,1.7515141414936957,9.980833608696305,1.3796836470005261e-11,0.3165729590790279,291.3371231920932,7.6727206619332,-0.3533,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-P3/72H370,GCL System Integration Technology Co Ltd,Multi-c-Si,0,370.0,344.9,2.01,,,72.0,9.94,47.9,9.18,40.3,0.00459228,-0.1355091,44.2,1.8316419325775664,9.957188396327004,4.195550343366697e-11,0.20557297677540587,118.88225989712886,7.8799461366946515,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72DH375,GCL System Integration Technology Co Ltd,Mono-c-Si,1,375.0,348.5,2.01,,,72.0,9.75,48.13,9.24,40.6,0.00318825,-0.14299423,43.4,1.8644440491835483,9.75320752250789,5.946834312814443e-11,0.1916380525772556,582.5278131022608,5.846121712855601,-0.3884,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72GDF375,GCL System Integration Technology Co Ltd,Mono-c-Si,0,375.0,348.1,2.04,,,72.0,9.88,48.28,9.38,39.98,0.005928000000000001,-0.1441158,43.72,1.8957319232591197,9.881764839067984,8.569184727677178e-11,0.2715869542234028,1520.4103094180252,8.012885794294887,-0.3861,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H375,GCL System Integration Technology Co Ltd,Mono-c-Si,0,375.0,350.0,2.01,,,72.0,9.75,48.13,9.24,40.6,0.003432,-0.13567847000000002,43.8,1.8028319750813393,9.754133696664859,2.4572768357595136e-11,0.20640185040204678,486.8325445342881,3.888888884650823,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72DH375,GCL System Integration Technology Co Ltd,Mono-c-Si,0,375.0,347.3,1.98,,,72.0,9.96,48.33,9.49,39.52,0.00324696,-0.1493397,43.9,1.8618446599095622,9.960004547412677,5.306221659890382e-11,0.3359568150691024,735874.8005926588,0.6243386818490746,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72GDF375,GCL System Integration Technology Co Ltd,Mono-c-Si,0,375.0,351.3,2.01,,,72.0,9.96,48.33,9.49,39.52,0.0046015200000000004,-0.13247253,42.4,1.8144641978496647,9.96000468488684,2.6940473753189767e-11,0.34663756002093793,736970.4913013397,7.290661358321228,-0.3679,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H375,GCL System Integration Technology Co Ltd,Mono-c-Si,0,375.0,349.8,1.98,,,72.0,10.05,48.0,9.47,39.6,0.00316575,-0.12451200000000001,44.3,1.7589919479098772,10.060452019334994,1.3946969628277492e-11,0.31234052906470905,300.32687820948394,7.695428279352928,-0.3533,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72DH380,GCL System Integration Technology Co Ltd,Mono-c-Si,1,380.0,353.3,2.01,,,72.0,9.79,48.34,9.29,40.9,0.0032013299999999996,-0.14361814,43.4,1.874304952909427,9.792509013951904,6.122528656138583e-11,0.17671831111301015,689.5427297363764,6.054654476786197,-0.3884,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72GDF380,GCL System Integration Technology Co Ltd,Mono-c-Si,0,380.0,352.8,2.04,,,72.0,9.96,48.47,9.46,40.17,0.005976,-0.14468295,43.72,1.9036120215980754,9.961509153482721,8.690871603927197e-11,0.26651235976193266,1758.9093941453746,8.064129818364806,-0.3861,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H380,GCL System Integration Technology Co Ltd,Mono-c-Si,0,380.0,354.8,2.01,,,72.0,9.79,48.34,9.29,40.9,0.00344608,-0.13627046,43.8,1.8123174879294206,9.793348220993119,2.530090842203743e-11,0.19151919377533927,559.990349421195,4.095031899606343,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72DH380,GCL System Integration Technology Co Ltd,Mono-c-Si,0,380.0,352.0,1.98,,,72.0,10.04,48.53,9.57,39.72,0.003273039999999999,-0.1499577,43.9,1.8706509508370672,10.040004575644755,5.431232126311719e-11,0.330142450177562,724449.2241258669,0.7480953804559983,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72GDF380,GCL System Integration Technology Co Ltd,Mono-c-Si,0,380.0,356.1,2.01,,,72.0,10.04,48.53,9.57,39.72,0.0046384799999999995,-0.13302073,42.4,1.822995989016397,10.04000471561142,2.756588606132956e-11,0.3408005537496841,725621.3315781668,7.420459870107498,-0.3679,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H380,GCL System Integration Technology Co Ltd,Mono-c-Si,0,380.0,353.4,1.94,,,72.0,10.13,48.2,9.55,39.8,0.004872530000000001,-0.1309112,45.0,1.8135278507994452,10.138851289815557,2.865251967890687e-11,0.2962018277582544,338.99291728184784,8.70098468338672,-0.3599,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72DH385,GCL System Integration Technology Co Ltd,Mono-c-Si,1,385.0,358.0,2.01,,,72.0,9.83,48.54,9.35,41.2,0.00321441,-0.14421234,43.4,1.8829363354580984,9.83147201280792,6.23726084302751e-11,0.16115789119324359,1076.2013415563401,6.169003203012962,-0.3884,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72GDF385,GCL System Integration Technology Co Ltd,Mono-c-Si,0,385.0,357.6,2.04,,,72.0,10.04,48.66,9.54,40.36,0.006023999999999999,-0.1452501,43.72,1.9114944933840912,10.041261137445543,8.813523490432087e-11,0.2615223420184586,2081.9973702349826,8.11523204685488,-0.3861,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H385,GCL System Integration Technology Co Ltd,Mono-c-Si,0,385.0,359.6,2.01,,,72.0,9.83,48.54,9.35,41.2,0.0034601600000000003,-0.13683425999999999,43.8,1.8206394870926148,9.832184869814457,2.577654386240014e-11,0.17596239123444443,791.6765949640254,4.208037206242599,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72DH385,GCL System Integration Technology Co Ltd,Mono-c-Si,0,385.0,356.8,1.98,,,72.0,10.12,48.73,9.65,39.92,0.0032991199999999996,-0.15057569999999998,43.9,1.8794551462636915,10.120004601907258,5.557877891631052e-11,0.3244248898206776,713479.7661751396,0.8706023669389202,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72GDF385,GCL System Integration Technology Co Ltd,Mono-c-Si,0,385.0,360.9,2.01,,,72.0,10.12,48.73,9.65,39.92,0.0046754399999999995,-0.13356893,42.4,1.831525711623806,10.120004744342493,2.8199251021600113e-11,0.3350607405912952,714729.7859339801,7.548932518428444,-0.3679,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H385,GCL System Integration Technology Co Ltd,Mono-c-Si,0,385.0,358.2,1.94,,,72.0,10.21,48.4,9.63,39.98,0.00491101,-0.1314544,45.0,1.8209809471387768,10.218517401266318,2.8863587463193443e-11,0.293355470277071,351.6517891201152,8.694465800556719,-0.3599,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72DH390,GCL System Integration Technology Co Ltd,Mono-c-Si,1,390.0,362.8,2.01,,,72.0,9.87,48.74,9.4,41.5,0.00322749,-0.14480654,43.4,1.89258755560809,9.87097012930954,6.433969682831067e-11,0.14552471115986207,1480.5541830632255,6.395048495471583,-0.3884,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72GDF390,GCL System Integration Technology Co Ltd,Mono-c-Si,0,390.0,362.4,2.04,,,72.0,10.12,48.85,9.62,40.55,0.006071999999999999,-0.14581725,43.72,1.919379242733061,10.121020651033353,8.937133363543285e-11,0.25661482277519815,2544.3982067964207,8.16617491524797,-0.3861,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M3/72H390,GCL System Integration Technology Co Ltd,Mono-c-Si,0,390.0,364.4,2.01,,,72.0,9.87,48.74,9.4,41.5,0.00347424,-0.13739806000000002,43.8,1.8299166900137303,9.871594606064072,2.659181915612506e-11,0.16036708169716318,992.6107571522626,4.431456072225072,-0.3586,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H390,GCL System Integration Technology Co Ltd,Mono-c-Si,0,390.0,363.0,1.94,,,72.0,10.29,48.6,9.71,40.17,0.004949489999999999,-0.13199760000000002,45.0,1.8286716643526482,10.298168661980423,2.9174284407425445e-11,0.2893662906661115,364.5124711130051,8.718227004191416,-0.3599,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M6/72H395,GCL System Integration Technology Co Ltd,Mono-c-Si,0,395.0,367.7,1.94,,,72.0,10.37,48.8,9.79,40.35,0.0049879699999999996,-0.13254080000000001,45.0,1.8361307728438643,10.377844521895058,2.938776356152633e-11,0.28662011957598854,378.8950715583536,8.712405061277632,-0.3599,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M10/72GDF530,GCL System Integration Technology Co Ltd,Mono-c-Si,1,530.0,495.2,2.56,,,72.0,13.68,48.68,12.94,40.96,0.00578664,-0.12617856,45.7,1.7468579741519432,13.68936990994879,1.0655869193256864e-11,0.17091644184406593,249.5367559218426,2.6899027744239046,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M10/72GDF535,GCL System Integration Technology Co Ltd,Mono-c-Si,1,535.0,500.0,2.56,,,72.0,13.73,48.96,12.98,41.22,0.00580779,-0.12690432000000001,45.7,1.7857733531592175,13.739005375779536,1.6780749415260214e-11,0.16422638919610977,250.38692331109957,6.52484448362002,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M10/72GDF540,GCL System Integration Technology Co Ltd,Mono-c-Si,1,540.0,504.8,2.56,,,72.0,13.78,49.24,13.03,41.45,0.0058289399999999995,-0.12763008,45.7,1.795681902651257,13.788898446075725,1.6768145867864563e-11,0.16509308604747117,255.6610694681929,6.485886197325778,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M10/72GDF545,GCL System Integration Technology Co Ltd,Mono-c-Si,1,545.0,509.6,2.56,,,72.0,13.83,49.52,13.07,41.7,0.00585009,-0.12835584,45.7,1.806683899312366,13.83930445637654,1.7020598349495175e-11,0.16411845094791905,243.94312735016132,6.586530477040428,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M10/72GDF550,GCL System Integration Technology Co Ltd,Mono-c-Si,1,550.0,514.4,2.56,,,72.0,13.88,49.8,13.12,41.93,0.00587124,-0.1290816,45.7,1.8165919320512172,13.889199276996205,1.7007458625337057e-11,0.1649797788001541,248.92383950757437,6.547598429437167,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +GCL System Integration Technology Co Ltd GCL-M10/72GDF555,GCL System Integration Technology Co Ltd,Mono-c-Si,1,555.0,519.2,2.56,,,72.0,13.93,50.08,13.16,42.18,0.00589239,-0.12980736,45.7,1.8275975659760109,13.93960105041386,1.7260977377091352e-11,0.1640110092289829,237.96077202335042,6.647222204324512,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +GE Energy GEPVp-200-M,GE Energy,Multi-c-Si,0,200.0,173.1,1.456785,1.485,0.981,54.0,8.25,32.6,7.7,25.9,0.0061262376237623765,-0.12110245656081485,50.5,1.4330986698415658,8.25877365181008,1.0769789495225909e-09,0.33869192093661493,318.477468258934,7.750616422903705,-0.4916241062308478,N,2025.7.3,6/23/2025,4.0,first_pass +GE Energy GEPVp-205-M,GE Energy,Multi-c-Si,0,205.0,177.6,1.456785,1.485,0.981,54.0,8.2,33.0,7.6,27.2,0.0060891089108910884,-0.12258837627321749,50.5,1.4895566352769654,8.2097767162445,1.9133020949954992e-09,0.1902167244858128,159.54004047282316,13.024014260003616,-0.4916241062308478,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-60-245W,GermanSolar USA,Multi-c-Si,0,245.0,219.7,1.64505,1.65,0.997,60.0,8.76,37.5,8.14,30.1,0.00449388,-0.13485,45.7,1.6008608635901653,8.774992506233136,5.759899166255484e-10,0.3370279917946102,196.9227705873778,5.5960000570802535,-0.473,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-60-250W,GermanSolar USA,Multi-c-Si,0,250.0,225.6,1.6268799999999999,1.64,0.992,60.0,8.85,37.5,8.31,30.1,0.0055046999999999995,-0.1323375,45.4,1.5815796769791977,8.856162962731238,4.4268767410586365e-10,0.33660934233134393,483.3704182357492,5.100236388285716,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-60-255W,GermanSolar USA,Multi-c-Si,0,255.0,230.2,1.6268799999999999,1.64,0.992,60.0,8.95,37.8,8.39,30.5,0.0055669,-0.1333962,45.4,1.600555742423193,8.957629713117784,4.903743134293126e-10,0.3129708680678995,367.1291544013609,5.885221890544791,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-260W,GermanSolar USA,Mono-c-Si,0,260.0,235.3,1.6268799999999999,1.64,0.992,60.0,9.14,38.1,8.47,30.7,0.0037839600000000003,-0.1365123,45.7,1.5705549447853373,9.160004358859862,2.594722150761994e-10,0.32651315528140556,149.18401035307164,-0.8268434605002423,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-60-260W,GermanSolar USA,Multi-c-Si,0,260.0,234.9,1.6268799999999999,1.64,0.992,60.0,9.01,38.0,8.42,30.7,0.00560422,-0.134102,45.4,1.6129246606868075,9.020232633558642,5.206570504003918e-10,0.3068903317317515,270.2219828418724,6.35359640326096,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-265W,GermanSolar USA,Mono-c-Si,0,265.0,239.9,1.6268799999999999,1.64,0.992,60.0,9.16,38.3,8.56,30.95,0.00379224,-0.13722890000000001,45.7,1.5743251191944307,9.172177761685607,2.4507548017508304e-10,0.3156255681816209,237.4106659374799,-1.3258869015817167,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-60-265W,GermanSolar USA,Multi-c-Si,0,265.0,239.5,1.6268799999999999,1.64,0.992,60.0,9.2,38.3,8.47,30.89,0.0057224,-0.1351607,45.4,1.637445926504635,9.223450160011637,6.188292763357471e-10,0.3089860244311678,121.22184983387447,7.719146924023103,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-270W,GermanSolar USA,Mono-c-Si,0,270.0,242.1,1.6268799999999999,1.64,0.992,60.0,9.34,38.63,8.81,30.72,0.00486614,-0.12118231,47.4,1.5826946608006376,9.342590628411061,2.3387860831589717e-10,0.37508385762151936,1352.291897440361,12.009963538187574,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-60-270W,GermanSolar USA,Multi-c-Si,0,270.0,244.2,1.6268799999999999,1.64,0.992,60.0,9.31,38.5,8.57,31.11,0.00579082,-0.1358665,45.4,1.6480096756539364,9.333334354743492,6.441185566604787e-10,0.29877110632751225,119.20446778904144,7.966656084260083,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-275W,GermanSolar USA,Mono-c-Si,0,275.0,246.7,1.6268799999999999,1.64,0.992,60.0,9.42,38.97,8.88,30.99,0.00490782,-0.12224888999999999,47.4,1.5971044250460518,9.423296596413348,2.3744442830587485e-10,0.37524735245322866,1072.2671775099707,12.071980655676196,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-280W,GermanSolar USA,Mono-c-Si,0,280.0,251.3,1.6268799999999999,1.64,0.992,60.0,9.51,39.31,8.96,31.26,0.00495471,-0.12331547,47.4,1.6114634246546904,9.513934517408861,2.4110533154017177e-10,0.3750103830643723,906.4264194954297,12.126404234784212,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-285W,GermanSolar USA,Mono-c-Si,0,285.0,256.0,1.6268799999999999,1.64,0.992,60.0,9.59,39.65,9.04,31.53,0.00499639,-0.12438205,47.4,1.6249739394825296,9.593386177842543,2.41726230671783e-10,0.37512678965221785,1062.3978306132437,12.071951475467273,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-290W,GermanSolar USA,Mono-c-Si,0,290.0,260.6,1.6268799999999999,1.64,0.992,60.0,9.67,39.99,9.12,31.8,0.00503807,-0.12544863,47.4,1.6384850474727,9.672837809525854,2.4235710154783084e-10,0.37524088102288705,1278.6558838435762,12.018507462977505,-0.4509,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-60-295W,GermanSolar USA,Mono-c-Si,0,295.0,266.8,1.64505,1.65,0.997,60.0,9.67,39.64,9.2,32.14,0.0025238700000000005,-0.13517240000000003,45.92,1.6184020770365188,9.670002739878282,2.229060319877975e-10,0.28323540391267277,999999.8543714592,2.601897903515497,-0.4566,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA GSM6-60-300W,GermanSolar USA,Mono-c-Si,0,300.0,271.5,1.64505,1.65,0.997,60.0,9.78,39.82,9.33,32.25,0.00255258,-0.1357862,45.92,1.6269493391491126,9.78000268523772,2.2954561567734158e-10,0.2744653420301609,999999.6368630606,2.75049405076696,-0.4566,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA GSP6-72-300W,GermanSolar USA,Multi-c-Si,0,300.0,270.8,1.9403519999999999,1.956,0.992,72.0,8.79,45.3,8.12,36.5,0.005467379999999999,-0.15986369999999997,45.4,1.9319266059428346,8.809846760788295,5.602726904203442e-10,0.38809513560148223,171.884810070385,7.238995060185336,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-72-305W,GermanSolar USA,Multi-c-Si,0,305.0,275.4,1.9403519999999999,1.956,0.992,72.0,9.05,45.6,8.16,37.4,0.005629100000000001,-0.1609224,45.4,1.993668562463311,9.08077376061129,9.941518140653664e-10,0.2801715951458923,82.39334731738569,12.171488333461008,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-72-310W,GermanSolar USA,Mono-c-Si,0,310.0,280.5,1.9403519999999999,1.956,0.992,72.0,9.0,46.1,8.33,37.2,0.0037259999999999997,-0.1651763,45.7,1.9032231312975005,9.020485178517065,2.646596828287812e-10,0.3935068632909849,172.88411790308876,-0.540525270150336,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-72-310W,GermanSolar USA,Multi-c-Si,0,310.0,280.0,1.9403519999999999,1.956,0.992,72.0,9.08,45.8,8.22,37.7,0.00564776,-0.16162819999999997,45.4,2.002040143432612,9.106611535989034,9.976648291774827e-10,0.26183822594124917,89.34062636589721,12.162196794937042,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-72-315W,GermanSolar USA,Mono-c-Si,0,315.0,285.2,1.9403519999999999,1.956,0.992,72.0,9.05,46.1,8.38,37.6,0.0037467000000000004,-0.1651763,45.7,1.9147730841855155,9.067852865268847,3.077851528163356e-10,0.33499693091050614,169.81713475076808,0.6334646410607018,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-72-315W,GermanSolar USA,Multi-c-Si,0,315.0,284.7,1.9403519999999999,1.956,0.992,72.0,9.17,45.9,8.31,37.9,0.00570374,-0.1619811,45.4,2.0090143509586116,9.19467527883562,1.0387992692334815e-09,0.2432725167277765,90.4066438722033,12.439225535941267,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-72-320W,GermanSolar USA,Mono-c-Si,0,320.0,289.8,1.9403519999999999,1.956,0.992,72.0,9.08,46.3,8.46,37.8,0.0037591200000000003,-0.16589289999999998,45.7,1.9176257709337567,9.09318294463199,2.904761636799889e-10,0.33103237470929825,228.0047665803272,0.11798324008091653,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-72-320W,GermanSolar USA,Multi-c-Si,0,320.0,289.3,1.9403519999999999,1.956,0.992,72.0,9.2,46.2,8.33,38.4,0.0057224,-0.1630398,45.4,2.0314144841711967,9.221580891648692,1.1546733871672618e-09,0.20778742355271246,88.58042047716114,13.38681739054855,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-72-325W,GermanSolar USA,Mono-c-Si,0,325.0,294.5,1.9403519999999999,1.956,0.992,72.0,9.11,46.55,8.55,37.98,0.00377154,-0.16678864999999998,45.7,1.9196762445152793,9.117890978526985,2.648408051863548e-10,0.33596254744372284,387.8630494696892,-0.6757536732771764,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSP6-72-325W,GermanSolar USA,Multi-c-Si,0,325.0,294.0,1.9403519999999999,1.956,0.992,72.0,9.25,46.4,8.37,38.8,0.0057535,-0.1637456,45.4,2.048589764234632,9.268523225207323,1.2723624622686112e-09,0.17415396183586374,86.96780723744364,14.241099486579074,-0.4577,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-72-330W,GermanSolar USA,Mono-c-Si,0,330.0,299.2,1.9403519999999999,1.956,0.992,72.0,9.15,46.84,8.61,38.31,0.0037881000000000004,-0.16782772,45.7,1.9316451407208473,9.155878701050703,2.6679072507184947e-10,0.32412391986159217,504.4880204625555,-0.6604792085095078,-0.4436,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA GSM6-72-335W,GermanSolar USA,Mono-c-Si,0,335.0,300.0,1.9403519999999999,1.956,0.992,72.0,9.18,46.99,8.7,38.49,0.003672,-0.164465,46.5,2.001476660063637,9.180003328194703,5.842779318254614e-10,0.30068929762084834,829809.7624914033,8.294291059006584,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-205W-CG,GermanSolar USA Inc,Mono-c-Si,0,205.0,194.6,0.94,,,56.0,12.44,20.38,11.64,17.61,0.00549848,-0.04649696999999999,43.4,0.7212673488976109,12.448624777738642,6.463263849951594e-12,0.03756961087770447,54.1887540591005,13.006072014048714,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-210W-CG,GermanSolar USA Inc,Mono-c-Si,0,210.0,199.4,0.94,,,56.0,12.72,20.41,11.9,17.64,0.005622240000000001,-0.046565415,43.4,0.7224662079786549,12.728781458897554,6.642851079135058e-12,0.03639300349450194,52.71550200624887,13.054708940616734,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-215W-CG,GermanSolar USA Inc,Mono-c-Si,0,215.0,204.3,0.94,,,56.0,13.0,20.44,12.17,17.67,0.005746,-0.046633860000000006,43.4,0.7233777913961847,13.008672825165897,6.754437251433814e-12,0.035340875793237456,52.97367084518146,13.004093862340248,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-220W-CG,GermanSolar USA Inc,Mono-c-Si,0,220.0,209.1,0.94,,,56.0,13.28,20.47,12.43,17.7,0.005869760000000001,-0.046702305,43.4,0.724577588460101,13.28882278375094,6.935658006299651e-12,0.03426074538918733,51.56906390598798,13.052913236969912,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-225W-CG,GermanSolar USA Inc,Mono-c-Si,0,225.0,214.0,0.94,,,56.0,13.56,20.5,12.69,17.72,0.0059935200000000004,-0.04677075,43.4,0.7255819295754181,13.569200606561948,7.0648340912204704e-12,0.03411935483469929,50.28564675981793,13.029616375435074,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-265W-AG,GermanSolar USA Inc,Mono-c-Si,0,265.0,251.5,1.21,,,72.0,12.49,26.21,11.7,22.64,0.005520580000000001,-0.059798115,43.4,0.9269478978134204,12.498428091951517,6.370793876330798e-12,0.048992924489819796,72.60500132359532,12.829740110216093,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-265W-CG,GermanSolar USA Inc,Mono-c-Si,0,265.0,251.5,1.21,,,72.0,12.5,26.21,11.7,22.64,0.005525,-0.059798115,43.4,0.9273025850244084,12.50868980217298,6.439189737900529e-12,0.0488605230512607,70.28428569545584,12.925166146363381,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-270W-AG,GermanSolar USA Inc,Mono-c-Si,0,270.0,256.4,1.21,,,72.0,12.71,26.24,11.9,22.68,0.005617820000000001,-0.05986655999999999,43.4,0.9079172539127275,12.719535305469604,3.4623355969535478e-12,0.05085722401392165,67.78968115087893,7.163254478237414,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-270W-CG,GermanSolar USA Inc,Mono-c-Si,0,270.0,256.4,1.21,,,72.0,12.71,26.24,11.9,22.68,0.005617820000000001,-0.05986655999999999,43.4,0.9079172539127275,12.719535305469604,3.4623355969535478e-12,0.05085722401392165,67.78968115087893,7.163254478237414,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-270W,GermanSolar USA Inc,Multi-c-Si,0,270.0,248.4,1.66,,,60.0,8.99,37.92,8.46,31.91,0.004755710000000001,-0.12274704,44.1,1.5385118472896677,8.994836577418203,1.751815693290355e-10,0.15590186769342465,289.7829895571436,6.383400145066155,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-275W-AG,GermanSolar USA Inc,Mono-c-Si,0,275.0,261.3,1.21,,,72.0,12.92,26.28,12.11,22.72,0.005710640000000001,-0.05995782000000001,43.4,0.9076462117270828,12.929280332278726,3.3429320466925286e-12,0.049967014217122144,69.56365403058984,6.703523060248682,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-275W-CG,GermanSolar USA Inc,Mono-c-Si,0,275.0,261.3,1.21,,,72.0,12.93,26.28,12.11,22.72,0.00571506,-0.05995782000000001,43.4,0.9298815470437607,12.938457748718065,6.685853185436291e-12,0.04560298906245794,69.71673771127139,12.957311500486641,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-275W,GermanSolar USA Inc,Multi-c-Si,0,275.0,253.1,1.66,,,60.0,9.08,38.32,8.51,32.31,0.004803320000000001,-0.12404183999999999,44.1,1.5598892398832362,9.086183483082769,1.9096946113832766e-10,0.1463778750635566,214.94538643555686,7.056582296406556,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-275W-H,GermanSolar USA Inc,Multi-c-Si,0,275.0,254.4,1.69,,,120.0,9.21,37.73,8.63,31.87,0.00524049,-0.11771759999999999,43.8,1.5077947910964629,9.216703152671581,1.2242592232356767e-10,0.14181285543350572,194.8480804496074,7.022065220984831,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-280W-AG,GermanSolar USA Inc,Mono-c-Si,0,280.0,266.1,1.21,,,72.0,13.13,26.32,12.31,22.75,0.005803460000000001,-0.06004908,43.4,0.9068572725382656,13.13951734499136,3.1705544593063326e-12,0.05006821361637799,69.07342810553749,6.095160988738002,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-280W-CG,GermanSolar USA Inc,Mono-c-Si,0,280.0,266.1,1.21,,,72.0,13.14,26.32,12.31,22.75,0.005807880000000001,-0.06004908,43.4,0.905789220942533,13.149872327666156,3.0633152484305657e-12,0.05021837672195648,66.8403129089976,5.790940015213762,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-280W,GermanSolar USA Inc,Multi-c-Si,0,280.0,257.8,1.66,,,60.0,9.18,38.55,8.6,32.55,0.00485622,-0.12478634999999998,44.1,1.5708700384586236,9.186171177262567,1.9789195219722836e-10,0.1393079365106916,207.22900256766238,7.271808202843596,-0.4064,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSP-280W-H,GermanSolar USA Inc,Multi-c-Si,0,280.0,259.2,1.69,,,120.0,9.24,38.03,8.71,32.15,0.0052575600000000005,-0.11865360000000001,43.8,1.515627590108947,9.24437566620234,1.1548435349541404e-10,0.14027361127189086,296.21277181297165,6.468375806261087,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-285W-AG,GermanSolar USA Inc,Mono-c-Si,0,285.0,271.0,1.21,,,72.0,13.35,26.35,12.51,22.79,0.005900700000000001,-0.060117525,43.4,0.9046661085462884,13.35980991216794,2.904543998346235e-12,0.04867537553441045,66.24078304290902,5.18724461185548,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-285W-CG,GermanSolar USA Inc,Mono-c-Si,0,285.0,271.0,1.21,,,72.0,13.35,26.35,12.51,22.79,0.005900700000000001,-0.060117525,43.4,0.9046661085462884,13.35980991216794,2.904543998346235e-12,0.04867537553441045,66.24078304290902,5.18724461185548,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-285W,GermanSolar USA Inc,Multi-c-Si,0,285.0,262.6,1.66,,,60.0,9.25,38.9,8.68,32.83,0.00489325,-0.1259193,44.1,1.583272965016011,9.255692577108258,1.9412846284765009e-10,0.1420043756774299,230.7461993653301,7.03366723093393,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-285W-H,GermanSolar USA Inc,Multi-c-Si,0,285.0,263.9,1.69,,,120.0,9.34,38.16,8.81,32.35,0.00531446,-0.1190592,43.8,1.522599955164521,9.343888983121465,1.2029255273950503e-10,0.12753637941749188,306.29853366245106,6.725004714655487,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-290W-H,GermanSolar USA Inc,Multi-c-Si,0,290.0,268.6,1.69,,,120.0,9.45,38.39,8.87,32.7,0.0053770499999999995,-0.1197768,43.8,1.5398313865289652,9.45480391700206,1.3789065316346155e-10,0.10537776042083906,207.29331117314337,7.826405610642375,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-295W-H,GermanSolar USA Inc,Multi-c-Si,0,295.0,273.4,1.69,,,120.0,9.53,38.75,8.96,32.93,0.00542257,-0.12090000000000001,43.8,1.5508947185434394,9.534733643995905,1.320001620980335e-10,0.11582773569493975,233.18998090278868,7.366848487232658,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-300W,GermanSolar USA Inc,Mono-c-Si,0,300.0,277.6,1.67,,,60.0,9.76,39.85,8.86,33.86,0.00484096,-0.11927105000000002,43.8,1.6288162253617842,9.774911956242798,2.1808315465148842e-10,0.10636785531425931,69.61865126875276,16.599571288740098,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-305W,GermanSolar USA Inc,Mono-c-Si,0,305.0,282.4,1.67,,,60.0,9.84,40.08,8.94,34.14,0.00488064,-0.11995944,43.8,1.6397434116527476,9.85330143300826,2.251060524338241e-10,0.09533335076638004,70.52474595886697,16.818907663713457,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS310G1-60,GermanSolar USA Inc,Mono-c-Si,0,310.0,283.6,1.65,,,60.0,10.04,40.3,9.52,32.61,0.00052208,-0.10691589999999998,46.8,1.4934411624796926,10.044010291092627,1.9077258786843435e-11,0.33179748085688465,830.6745732430549,8.30332918726962,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-310G1B-60,GermanSolar USA Inc,Mono-c-Si,0,310.0,283.4,1.65,,,60.0,10.04,40.3,9.52,32.61,0.0005521999999999999,-0.0990977,48.2,1.4554746547570512,10.045319029917508,9.424408571415071e-12,0.34041956383597477,642.5631238033982,10.402619308604601,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-310W-CG,GermanSolar USA Inc,Mono-c-Si,0,310.0,294.3,1.41,,,84.0,12.53,30.58,11.73,26.42,0.005538260000000001,-0.06976827000000001,43.4,1.0495726628409834,12.539974502705043,2.699072509954961e-12,0.06286385466608094,78.96976145046061,5.104717693100609,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-310W,GermanSolar USA Inc,Mono-c-Si,0,310.0,287.1,1.67,,,60.0,9.92,40.32,9.02,34.38,0.00492032,-0.12067776000000001,43.8,1.6497549606331394,9.93259670585376,2.2778508128534794e-10,0.09079633750436529,71.50279528066193,16.851268751716734,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS315G1-60,GermanSolar USA Inc,Mono-c-Si,0,315.0,288.3,1.65,,,60.0,10.11,40.53,9.58,32.9,0.0005257199999999999,-0.10752608999999999,46.8,1.504817755437909,10.114849102262351,2.0196037404652273e-11,0.3188788240127309,664.8374971926852,8.744440364814862,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-315G1B-60,GermanSolar USA Inc,Mono-c-Si,0,315.0,288.1,1.65,,,60.0,10.11,40.53,9.58,32.9,0.00055605,-0.09966327,48.2,1.466481217042114,10.116140014552647,9.975295727225875e-12,0.32755302847104706,539.3409309142569,10.853120422488022,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-315W-CG,GermanSolar USA Inc,Mono-c-Si,0,315.0,299.1,1.41,,,84.0,12.71,30.62,11.9,26.46,0.005617820000000001,-0.06985953,43.4,1.0833843536654224,12.71858974260286,6.559148638170218e-12,0.055160029801612456,81.61874183106984,12.94052863662701,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-315W,GermanSolar USA Inc,Mono-c-Si,0,315.0,291.9,1.67,,,60.0,9.98,40.5,9.12,34.56,0.00495008,-0.12121650000000002,43.8,1.6530679846426963,9.991168334375885,2.1711892959820988e-10,0.08889456335439186,79.43599507938602,16.323475969993336,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS320G1-60,GermanSolar USA Inc,Mono-c-Si,0,320.0,293.1,1.65,,,60.0,10.18,40.78,9.65,33.18,0.00052936,-0.10818934,46.8,1.5156019447050382,10.1845613283535,2.089014733286121e-11,0.30940745066189773,690.5374281929802,8.978822411452972,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-320G1B-60,GermanSolar USA Inc,Mono-c-Si,0,320.0,292.8,1.65,,,60.0,10.18,40.78,9.65,33.18,0.0005599,-0.10027802,48.2,1.4769477197137808,10.18581798007528,1.0317081447068005e-11,0.31810501173135913,556.6035590522451,11.092333972590579,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-320W-CG,GermanSolar USA Inc,Mono-c-Si,0,320.0,304.0,1.41,,,84.0,12.89,30.66,12.07,26.5,0.005697380000000001,-0.06995079,43.4,1.0848416902162472,12.898593845292092,6.660175124379554e-12,0.053966563855831776,80.94502343899813,12.95131943844477,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-320W,GermanSolar USA Inc,Mono-c-Si,0,320.0,296.6,1.67,,,60.0,10.05,40.74,9.2,34.8,0.0049848,-0.12193482000000001,43.8,1.6621496262431033,10.060335267435493,2.1678386038733878e-10,0.08490633495469907,82.5628058131187,16.236692822946683,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-320W,GermanSolar USA Inc,Multi-c-Si,0,320.0,294.4,1.98,,,72.0,9.02,45.15,8.42,38.0,0.00477158,-0.14615055,44.1,1.8400811587799806,9.02797446359378,1.9437530573234764e-10,0.18197380809129826,205.83250362808218,7.281354410855928,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS325G1-60,GermanSolar USA Inc,Mono-c-Si,0,325.0,297.8,1.65,,,60.0,10.25,41.04,9.72,33.45,0.000533,-0.10887911999999998,46.8,1.5263392621077077,10.254268739597443,2.144140789443943e-11,0.30230535136817815,725.8887280912743,9.145924093446256,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-325G1B-60,GermanSolar USA Inc,Mono-c-Si,0,325.0,297.6,1.65,,,60.0,10.25,41.04,9.72,33.45,0.00056375,-0.10091736,48.2,1.4873805050682383,10.255499091109776,1.058857768884657e-11,0.31101932148811595,579.7227278179477,11.262869279540544,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-325W-AG,GermanSolar USA Inc,Mono-c-Si,0,325.0,308.6,1.47,,,88.0,12.53,32.03,11.74,27.68,0.005538260000000001,-0.073076445,43.4,1.0974615221797852,12.539637973149361,2.5701427058338667e-12,0.06557283286000443,85.2490023832716,4.675612633989951,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-325W-CG,GermanSolar USA Inc,Mono-c-Si,0,325.0,308.9,1.41,,,84.0,13.07,30.7,12.24,26.54,0.005776940000000001,-0.07004205,43.4,1.0863005771444283,13.078596697825828,6.761665391313246e-12,0.05280570828992651,80.28322290891401,12.962437625205586,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-325W,GermanSolar USA Inc,Mono-c-Si,0,325.0,301.4,1.67,,,60.0,10.1,41.05,9.25,35.13,0.0050095999999999995,-0.12286265,43.8,1.6761084906420056,10.10931476537827,2.2216362284776515e-10,0.07707277615060394,83.57001151319257,16.419021855054623,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-325W-H,GermanSolar USA Inc,Mono-c-Si,0,325.0,302.8,1.69,,,120.0,10.05,40.74,9.34,34.8,0.00493455,-0.12588660000000002,43.5,1.6170262886236133,10.057782680497592,1.1128504537516367e-10,0.09698499397762612,125.2395240048603,6.626752018108795,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-325W,GermanSolar USA Inc,Multi-c-Si,0,325.0,299.1,1.98,,,72.0,9.08,45.29,8.51,38.23,0.004803320000000001,-0.14660373000000002,44.1,1.844783756676636,9.085998980676768,1.9393974797389779e-10,0.16709632081709602,252.91540969016378,7.190302435400042,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS330G1-60,GermanSolar USA Inc,Mono-c-Si,0,330.0,302.5,1.65,,,60.0,10.32,41.3,9.78,33.76,0.00053664,-0.10956889999999998,46.8,1.5387369455610138,10.324981833806019,2.2617525584294074e-11,0.2905850115415679,601.9545247491031,9.559686723918148,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-330G1B-60,GermanSolar USA Inc,Mono-c-Si,0,330.0,302.3,1.65,,,60.0,10.32,41.3,9.78,33.76,0.0005675999999999999,-0.1015567,48.2,1.4993847003495018,10.326197701388066,1.116760334784946e-11,0.2993537687975971,498.46398506222977,11.685431916455846,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-330W-AG,GermanSolar USA Inc,Mono-c-Si,0,330.0,313.4,1.47,,,88.0,12.71,32.08,11.9,27.72,0.005617820000000001,-0.07319052,43.4,1.135009568431562,12.718612207122305,6.553970332728464e-12,0.05794696568068231,85.51883667819932,12.933191733026598,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-330W-CG,GermanSolar USA Inc,Mono-c-Si,0,330.0,313.7,1.41,,,84.0,13.25,30.74,12.41,26.59,0.005856500000000001,-0.07013331,43.4,1.0483124689491343,13.260209311388273,2.3663310273246985e-12,0.058276788313558835,75.63364618660195,3.482946588282833,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-330W,GermanSolar USA Inc,Mono-c-Si,0,330.0,306.1,1.67,,,60.0,10.17,41.4,9.31,35.44,0.00504432,-0.1239102,43.8,1.6911081049047028,10.17930062847153,2.2588609297595466e-10,0.07573620363217388,82.81560800853231,16.512189531692968,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-330W-H,GermanSolar USA Inc,Mono-c-Si,0,330.0,307.6,1.69,,,120.0,10.11,40.92,9.44,34.98,0.00496401,-0.1264428,43.5,1.6206595580747176,10.116374156631561,1.0658734639752935e-10,0.09492948021229337,150.56690829985985,6.187481387061957,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-330W,GermanSolar USA Inc,Multi-c-Si,0,330.0,303.8,1.98,,,72.0,9.18,45.44,8.6,38.38,0.00485622,-0.14708928,44.1,1.8519647581760954,9.186115614601547,1.9876565360311842e-10,0.16253067415918024,243.97084283545462,7.310035589246345,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-330W-H,GermanSolar USA Inc,Multi-c-Si,0,330.0,305.4,2.01,,,144.0,9.21,45.27,8.63,38.24,0.00524049,-0.14124240000000002,43.8,1.809141808740154,9.216698152037464,1.2247274043548567e-10,0.17000918798345918,233.76367869362718,7.025376782851049,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS335G1-60,GermanSolar USA Inc,Mono-c-Si,0,335.0,307.2,1.65,,,60.0,10.39,41.59,9.85,34.07,0.00054028,-0.11033827,46.8,1.5509456693443266,10.394689722031348,2.333598521916783e-11,0.2821124095077643,625.0152987917179,9.77465712230607,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-335G1B-60,GermanSolar USA Inc,Mono-c-Si,0,335.0,307.0,1.65,,,60.0,10.39,41.59,9.85,34.07,0.00057145,-0.10226981000000002,48.2,1.5112411736551414,10.395873417609165,1.1521332051567095e-11,0.2909104115103268,514.616772462106,11.904824967610447,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-335W-AG,GermanSolar USA Inc,Mono-c-Si,0,335.0,318.3,1.47,,,88.0,12.88,32.12,12.07,27.76,0.00569296,-0.07328177999999999,43.4,1.1360424542605285,12.8883648925547,6.5855680706953794e-12,0.05686785163247097,87.56333984883253,12.850313428170828,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-335W-H,GermanSolar USA Inc,Mono-c-Si,0,335.0,312.3,1.69,,,120.0,10.2,40.92,9.53,35.16,0.005008199999999999,-0.1264428,43.5,1.6246635913914584,10.20487112294671,1.1447259469510404e-10,0.07241984794816515,151.64520928204965,6.723011995968166,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-335W,GermanSolar USA Inc,Multi-c-Si,0,335.0,308.5,1.98,,,72.0,9.21,45.65,8.68,38.6,0.004872090000000001,-0.14776905,44.1,1.8556022531691265,9.213880408889574,1.8816528784880382e-10,0.15877807935542615,376.8536351479749,6.7858793293698305,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-335W-H,GermanSolar USA Inc,Multi-c-Si,0,335.0,310.1,2.01,,,144.0,9.28,45.63,8.69,38.56,0.00528032,-0.1423656,43.8,1.8245747847910143,9.286911904424004,1.2508654463564841e-10,0.16776712829056392,225.24602381508342,7.145051583931967,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-340W-AG,GermanSolar USA Inc,Mono-c-Si,0,340.0,323.1,1.47,,,88.0,13.05,32.16,12.23,27.81,0.005768100000000001,-0.07337304,43.4,1.1377250650465653,13.058249770417309,6.717196737630016e-12,0.05477449317692972,86.64570046397833,12.912058998970927,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-340W-H,GermanSolar USA Inc,Mono-c-Si,0,340.0,317.1,1.69,,,120.0,10.26,41.27,9.6,35.42,0.005037659999999999,-0.1275243,43.5,1.6362281496414135,10.26490701287256,1.1128919691898269e-10,0.07795405859538818,162.99298031988528,6.42417572579836,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-340W,GermanSolar USA Inc,Multi-c-Si,0,340.0,313.2,1.98,,,72.0,9.35,45.86,8.77,38.8,0.00494615,-0.14844882,44.1,1.8695903041078135,9.355516400800566,2.0406397606203988e-10,0.15274634653577687,258.8967792965655,7.374762487562601,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-340W-H,GermanSolar USA Inc,Multi-c-Si,0,340.0,314.8,2.01,,,144.0,9.35,45.88,8.77,38.77,0.00532015,-0.1431456,43.8,1.832912421634285,9.356354928851525,1.2345084369377067e-10,0.1680446751750474,247.24395677800032,6.960045003970926,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-345W-AG,GermanSolar USA Inc,Mono-c-Si,0,345.0,328.0,1.47,,,88.0,13.22,32.21,12.39,27.85,0.005843240000000001,-0.07348711499999999,43.4,1.1394013322531222,13.228383495556496,6.7895899664049455e-12,0.05445793942001762,85.87515253147599,12.89115830910132,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-345W-H,GermanSolar USA Inc,Mono-c-Si,0,345.0,321.1,1.85,,,120.0,11.02,39.98,10.5,32.86,0.005047159999999999,-0.1181409,43.9,1.515186220369695,11.02000400157068,3.826486640123265e-11,0.23858229539572953,657065.4724777597,1.5075197871109918,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-345W,GermanSolar USA Inc,Multi-c-Si,0,345.0,317.9,1.98,,,72.0,9.41,46.16,8.85,39.04,0.0049778900000000004,-0.14941991999999998,44.1,1.8786940712739444,9.414676165962913,1.9779421142013843e-10,0.1553825898510751,312.681426392843,7.03912273165469,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-345W-H,GermanSolar USA Inc,Multi-c-Si,0,345.0,319.6,2.01,,,144.0,9.41,46.05,8.85,38.99,0.00535429,-0.143676,43.8,1.8390385481220621,9.41510527462803,1.2349174721540436e-10,0.15831079899132308,291.7971650918831,6.897945241010231,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-350W-H,GermanSolar USA Inc,Mono-c-Si,0,350.0,325.8,1.85,,,120.0,11.09,40.24,10.57,33.11,0.00507922,-0.1189092,43.9,1.5259825897840233,11.090004008496601,3.9140789150360416e-11,0.2346038605767708,649088.9700377228,1.6412295953094447,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-350W,GermanSolar USA Inc,Multi-c-Si,0,350.0,322.7,1.98,,,72.0,9.48,46.5,8.9,39.33,0.005014920000000001,-0.1505205,44.1,1.8944325057535192,9.485325827949463,2.0380717274882375e-10,0.15452682103883703,275.0585153633115,7.240758474655898,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-350W-H,GermanSolar USA Inc,Multi-c-Si,0,350.0,324.3,2.01,,,144.0,9.48,46.26,8.9,39.33,0.0053941200000000005,-0.1443312,43.8,1.8533883309914043,9.485085016749608,1.3451285841053004e-10,0.13622415249864825,253.9627819693907,7.581873744024982,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-355W-H,GermanSolar USA Inc,Mono-c-Si,0,355.0,330.6,1.85,,,120.0,11.16,40.5,10.64,33.36,0.00511128,-0.1196775,43.9,1.536779183659968,11.160004013463286,4.002615307423466e-11,0.23067833826543246,641461.337641343,1.7732552430994866,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-355W,GermanSolar USA Inc,Multi-c-Si,0,355.0,327.4,1.98,,,72.0,9.56,46.6,8.96,39.62,0.00505724,-0.1508442,44.1,1.9058010177742766,9.565018043513085,2.252093604978157e-10,0.12637961350286203,240.76896470215434,8.0430251711524,-0.4064,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSP-355W-H,GermanSolar USA Inc,Multi-c-Si,0,355.0,329.1,2.01,,,144.0,9.56,46.6,8.96,39.62,0.00543964,-0.14539200000000002,43.8,1.8687367361691973,9.565638105938312,1.3853524927093353e-10,0.13543597590752107,229.6459084679454,7.771480448827919,-0.3862,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-360W-H,GermanSolar USA Inc,Mono-c-Si,0,360.0,335.4,1.85,,,120.0,11.22,40.77,10.7,33.65,0.00513876,-0.12047535000000001,43.9,1.5485754814670492,11.220003964543901,4.131773215569982e-11,0.22366336262539277,633013.2969946548,1.990395615486456,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-365W,GermanSolar USA Inc,Mono-c-Si,0,365.0,338.0,1.98,,,72.0,9.68,47.45,9.08,40.24,0.00480128,-0.14201785,43.8,1.9023370137307918,9.685869819283955,1.3956419589485712e-10,0.1488394825044031,245.4532515811049,12.41917779442059,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-365W-H,GermanSolar USA Inc,Mono-c-Si,0,365.0,340.2,1.85,,,120.0,11.28,41.0,10.76,33.93,0.00516624,-0.121155,43.9,1.5593224771269625,11.280003869300423,4.297317541478227e-11,0.21405514379554602,624051.1419774588,2.270322190207665,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-370W,GermanSolar USA Inc,Mono-c-Si,0,370.0,342.7,1.98,,,72.0,9.77,48.02,9.17,40.39,0.004845919999999999,-0.14372386,43.8,1.9159731155605288,9.777086858705728,1.2512476905933285e-10,0.19160053095917123,264.14202033465654,11.345421347070502,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-370W-H,GermanSolar USA Inc,Mono-c-Si,0,370.0,345.0,1.85,,,120.0,11.35,41.27,10.82,34.2,0.0051983,-0.12195285000000002,43.9,1.5701250714456894,11.350003868627006,4.362816768892582e-11,0.20931896193768532,614136.5049313607,2.344157232345501,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-375G1-72,GermanSolar USA Inc,Mono-c-Si,0,375.0,349.2,1.97,,,72.0,9.99,48.44,9.45,39.74,0.00132867,-0.11218704,46.2,1.678408304422058,9.999916571723533,2.8854058631173667e-12,0.36516629781474724,367.87021009190477,6.436968889175587,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-375W,GermanSolar USA Inc,Mono-c-Si,0,375.0,347.5,1.98,,,72.0,9.86,48.09,9.26,40.53,0.0048905599999999995,-0.14393337000000003,43.8,1.920251684657416,9.866570163033478,1.288158600380092e-10,0.1801050078170409,270.28786692387877,11.522408944424093,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-375W-H,GermanSolar USA Inc,Mono-c-Si,0,375.0,349.7,1.85,,,120.0,11.43,41.61,10.89,34.45,0.00523494,-0.12295755,43.9,1.5824909255279698,11.430271680482544,4.350562721636459e-11,0.2129380038375077,8958.622219912391,2.264226469497683,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-380G1-72,GermanSolar USA Inc,Mono-c-Si,0,380.0,354.0,1.97,,,72.0,10.06,48.7,9.51,40.02,0.0013379800000000001,-0.1127892,46.2,1.6892181361339451,10.070481760067667,2.9936485521793085e-12,0.35659217636437596,342.2437909853039,6.701664558138126,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-380W,GermanSolar USA Inc,Mono-c-Si,0,380.0,352.3,1.98,,,72.0,9.9,48.45,9.3,40.86,0.0049104,-0.14501085000000002,43.8,1.9350432811793248,9.906383183912022,1.3006992080823024e-10,0.17746844170087248,275.24469812311685,11.572251638308675,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-385G1-72,GermanSolar USA Inc,Mono-c-Si,0,385.0,358.8,1.97,,,72.0,10.12,48.97,9.57,40.28,0.00134596,-0.11341452,46.2,1.6990773997330426,10.130157500082111,3.037788349222909e-12,0.3518912193858284,350.5920839278149,6.776309667608939,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-385W,GermanSolar USA Inc,Mono-c-Si,0,385.0,357.0,1.98,,,72.0,10.07,48.53,9.37,41.08,0.00499472,-0.14525029,43.8,1.9521440295406118,10.079441791895208,1.5630210100309956e-10,0.15334073970450013,163.54324441431436,13.122700766547341,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-390G1-72,GermanSolar USA Inc,Mono-c-Si,0,390.0,363.6,1.97,,,72.0,10.17,49.27,9.62,40.6,0.00135261,-0.11410932,46.2,1.710714137180687,10.179817810114862,3.117090029668755e-12,0.343619503146458,355.94601174090656,6.958074306597183,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-390W,GermanSolar USA Inc,Mono-c-Si,0,390.0,361.8,1.98,,,72.0,10.1,48.86,9.42,41.4,0.0050095999999999995,-0.14623798,43.8,1.9639751269770185,10.108350264106349,1.5434520427398842e-10,0.1496018133247416,180.94976729915143,12.971394869178846,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-390W-H,GermanSolar USA Inc,Mono-c-Si,0,390.0,363.4,2.01,,,144.0,10.12,49.3,9.49,41.1,0.00496892,-0.152337,43.5,1.9215958089534395,10.130078352767736,7.156637371431064e-11,0.24301682936566799,244.02105905388305,2.7988227165418644,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-395G1-72,GermanSolar USA Inc,Mono-c-Si,0,395.0,368.3,1.97,,,72.0,10.23,49.56,9.67,40.89,0.00136059,-0.11478096000000002,46.2,1.7223240516306988,10.240397730238598,3.2143050318873455e-12,0.33760290555126515,332.15688858900506,7.1798910561454505,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-395W,GermanSolar USA Inc,Mono-c-Si,0,395.0,366.5,1.98,,,72.0,10.17,49.32,9.5,41.57,0.00504432,-0.14761476,43.8,1.9750924975431683,10.17911543386758,1.419644769091241e-10,0.17729335942530178,197.80446358910035,12.141748349136783,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-395W-H,GermanSolar USA Inc,Mono-c-Si,0,395.0,368.2,2.01,,,144.0,10.23,49.5,9.55,41.4,0.00502293,-0.152955,43.5,1.937375253027486,10.242186658495108,7.9958746245891e-11,0.22438439991601924,188.3578214833999,3.6500290107315716,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-395W-HC,GermanSolar USA Inc,Mono-c-Si,0,395.0,373.7,1.79,,,108.0,13.67,36.72,12.86,30.71,0.006356550000000001,-0.0855576,43.3,1.313795715252191,13.68525267328328,9.747792557535463e-12,0.1457947191882901,130.66652506226413,13.460423582832371,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GS-400G1-72,GermanSolar USA Inc,Mono-c-Si,0,400.0,373.1,1.97,,,72.0,10.29,49.86,9.73,41.18,0.0013685699999999997,-0.11547576,46.2,1.7333264480831878,10.300072033321383,3.265224585990094e-12,0.3326880671004464,339.88769772599665,7.265232065655808,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-400W-AG,GermanSolar USA Inc,Mono-c-Si,0,400.0,379.8,1.81,,,108.0,12.58,39.26,11.8,33.91,0.00556036,-0.08957169,43.4,1.3875477458549925,12.588084492391124,6.30622233837287e-12,0.07332996378147313,114.1062296007328,12.662470056613149,-0.29641,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-400W,GermanSolar USA Inc,Mono-c-Si,0,400.0,371.3,1.98,,,72.0,10.26,49.5,9.57,41.79,0.00508896,-0.1481535,43.8,1.9856464253151116,10.269412985982635,1.490912256766437e-10,0.1677035597792075,182.79412676410433,12.512137974352083,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-400W-H,GermanSolar USA Inc,Mono-c-Si,0,400.0,373.0,2.01,,,144.0,10.21,49.8,9.6,41.7,0.00501311,-0.153882,43.5,1.943024178287658,10.217918499975175,7.427799894023173e-11,0.2216614439690911,285.80708427525565,3.0251924404921824,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-400W-HC-1,GermanSolar USA Inc,Mono-c-Si,0,400.0,378.5,1.79,,,108.0,13.75,37.24,12.9,31.01,0.00639375,-0.0867692,43.3,1.331298229864174,13.7689950971911,9.55376117785419e-12,0.1587984580746883,114.94959897120401,13.231275880129193,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-405W-AG,GermanSolar USA Inc,Mono-c-Si,0,405.0,384.6,1.81,,,108.0,12.72,39.31,11.92,33.97,0.005622240000000001,-0.089685765,43.4,1.390268971144246,12.728305758543412,6.493950149633173e-12,0.07085472154574846,108.51170981759704,12.83632579293154,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-405W,GermanSolar USA Inc,Mono-c-Si,0,405.0,376.1,1.98,,,72.0,10.26,50.1,9.65,42.0,0.00508896,-0.1499493,43.8,1.993179167149981,10.2668962909783,1.2252309383120022e-10,0.2076314393535297,308.9049700499357,10.709683975286877,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-405W-H,GermanSolar USA Inc,Mono-c-Si,0,405.0,377.8,2.01,,,144.0,10.26,50.1,9.65,42.0,0.005037659999999999,-0.154809,43.5,1.9556455291888484,10.267621504103383,7.556270967954922e-11,0.21611250802383558,290.9287128332615,3.12629715640941,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-405W-HC-1,GermanSolar USA Inc,Mono-c-Si,0,405.0,383.4,1.79,,,108.0,13.81,37.24,12.94,31.31,0.00642165,-0.0867692,43.3,1.3382902150999985,13.827348217142033,1.1079158347234815e-11,0.13155624142166494,104.72498028842446,14.579723206885483,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-410W-AG,GermanSolar USA Inc,Mono-c-Si,0,410.0,389.5,1.81,,,108.0,12.86,39.37,12.05,34.02,0.00568412,-0.089822655,43.4,1.3924211085195997,12.8684492373205,6.568709009678441e-12,0.07034740010772486,107.07091570196927,12.841427753123329,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-410W,GermanSolar USA Inc,Mono-c-Si,0,410.0,380.9,1.98,,,72.0,10.3,50.4,9.69,42.3,0.0051088,-0.15084720000000001,43.8,2.006104759482574,10.30664559006823,1.2455875393651528e-10,0.20230682074248107,313.555338141107,10.821442553327078,-0.3967,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-410W-H,GermanSolar USA Inc,Mono-c-Si,0,410.0,382.6,2.01,,,144.0,10.3,50.4,9.69,42.3,0.0050573,-0.155736,43.5,1.9683273120015423,10.307357264627619,7.683614003329928e-11,0.21081426181291424,295.13508786527746,3.2323847673020234,-0.3778,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-410W-HC-1,GermanSolar USA Inc,Mono-c-Si,0,410.0,388.2,1.79,,,108.0,13.88,37.5,12.97,31.6,0.0064542,-0.08737500000000001,43.3,1.350860230098492,13.898785562644495,1.1859853049414021e-11,0.12530675960128282,92.58481368993162,15.185206384502322,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-415W,GermanSolar USA Inc,Mono-c-Si,0,415.0,394.3,1.81,,,108.0,13.12,39.1,12.3,33.75,0.00579904,-0.08920665,43.4,1.381819861474191,13.128848012685348,6.563359099816017e-12,0.07194827116815308,106.68625283662354,12.64580771916426,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-415W-AG,GermanSolar USA Inc,Mono-c-Si,0,415.0,394.3,1.81,,,108.0,12.99,39.42,12.18,34.07,0.005741580000000001,-0.08993673,43.4,1.393873576428921,12.99824239358034,6.597812021664874e-12,0.06921296488226711,109.07952959956876,12.785993039494809,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-415W-H,GermanSolar USA Inc,Mono-c-Si,0,415.0,386.3,2.21,,,144.0,11.0,48.0,10.46,39.67,0.005038,-0.14184,43.9,1.8220542446778953,11.000008649332278,3.984561200337595e-11,0.26352078917082455,332621.0308638879,1.8548290651371002,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-415W-HC-1,GermanSolar USA Inc,Mono-c-Si,0,415.0,393.1,1.79,,,108.0,13.95,37.73,13.01,31.89,0.0064867499999999995,-0.0879109,43.3,1.3624093864649787,13.969093741482062,1.2706683911913827e-11,0.11682762147290739,85.35494856158701,15.79852013665448,-0.3179,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-108-420W,GermanSolar USA Inc,Mono-c-Si,0,420.0,399.2,1.81,,,108.0,13.26,39.15,12.42,33.8,0.00586092,-0.089320725,43.4,1.3843168475806928,13.269182866431985,6.725869206988892e-12,0.07050963672865049,101.81546150504052,12.778380356140179,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-420W-AG,GermanSolar USA Inc,Mono-c-Si,0,420.0,399.2,1.81,,,108.0,13.13,39.47,12.31,34.13,0.005803460000000001,-0.090050805,43.4,1.3960347900882526,13.138183703098022,6.7211790838351615e-12,0.0669987990772815,107.49341979102677,12.858917438419594,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-420W-H,GermanSolar USA Inc,Mono-c-Si,0,420.0,391.1,2.21,,,144.0,11.06,48.26,10.52,39.92,0.00506548,-0.1426083,43.9,1.836033856803855,11.061563569653234,4.2401978140363704e-11,0.2590139268613766,1832.150116860595,2.3301745294986342,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-425W,GermanSolar USA Inc,Mono-c-Si,0,425.0,404.1,1.81,,,108.0,13.4,39.2,12.55,33.86,0.005922800000000001,-0.0894348,43.4,1.3864707194346626,13.409116422768921,6.849596245644446e-12,0.06832675460434395,100.43177412679992,12.850499368144034,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-Agri-425W-AG,GermanSolar USA Inc,Mono-c-Si,0,425.0,404.1,1.81,,,108.0,13.27,39.53,12.43,34.18,0.00586534,-0.09018769500000001,43.4,1.3987253833030249,13.278583743487502,6.864097111553131e-12,0.0664119593509713,102.66927371929569,12.960027812190596,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-425W-H,GermanSolar USA Inc,Mono-c-Si,0,425.0,395.8,2.21,,,144.0,11.12,48.52,10.58,40.17,0.00509296,-0.1433766,43.9,1.8465155244308635,11.12138363887412,4.300182884884617e-11,0.2552120412825835,2051.083024250085,2.4007326744576742,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-430W,GermanSolar USA Inc,Mono-c-Si,0,430.0,408.9,1.81,,,108.0,13.53,39.26,12.68,33.91,0.00598026,-0.08957169,43.4,1.388126298200477,13.539000289914222,6.855883583905842e-12,0.06804158296354179,102.28588489502087,12.766404268730632,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-430W-H,GermanSolar USA Inc,Mono-c-Si,0,430.0,400.6,2.21,,,144.0,11.18,48.79,10.63,40.47,0.0051204399999999995,-0.14417444999999998,43.9,1.8592394180408724,11.181992953381926,4.47126717088859e-11,0.24688854564216173,1384.9868123725635,2.682462378777458,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-435W,GermanSolar USA Inc,Mono-c-Si,0,435.0,413.8,1.81,,,108.0,13.67,39.31,12.81,33.97,0.006042140000000001,-0.089685765,43.4,1.3902820063565309,13.6789328089439,6.98064425254561e-12,0.06592750564961485,100.8897658617726,12.838664155169345,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-435W-H,GermanSolar USA Inc,Mono-c-Si,0,435.0,405.4,2.21,,,144.0,11.24,49.01,10.67,40.76,0.00514792,-0.14482455,43.9,1.8642459934362632,11.24000720143414,4.2993105282008134e-11,0.23627941571874547,368791.9132484709,2.3035027235772,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-440W,GermanSolar USA Inc,Mono-c-Si,0,440.0,418.7,1.81,,,108.0,13.8,39.37,12.93,34.02,0.006099600000000001,-0.089822655,43.4,1.3924618946878446,13.80908809708812,7.0541816146360524e-12,0.06554586461548678,99.52940910625779,12.848733104234348,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-440W-H,GermanSolar USA Inc,Mono-c-Si,0,440.0,410.2,2.21,,,144.0,11.29,49.29,10.72,41.06,0.0051708200000000005,-0.14565195,43.9,1.876456429023408,11.290009849717876,4.413823587672928e-11,0.22934394407764797,262883.43206404144,2.484097188176152,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-445W,GermanSolar USA Inc,Mono-c-Si,0,445.0,423.6,1.81,,,108.0,13.94,39.42,13.06,34.07,0.00616148,-0.08993673,43.4,1.3944217439162334,13.949131254211505,7.15258840918131e-12,0.06436597570909748,98.26270096488498,12.88405849789553,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM-445W-H,GermanSolar USA Inc,Mono-c-Si,0,445.0,414.9,2.21,,,144.0,11.33,49.54,10.77,41.33,0.00518914,-0.14639069999999998,43.9,1.8881165476497341,11.330007648052362,4.56350254023362e-11,0.22289046158505665,330200.57201688265,2.73097875250157,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-450W,GermanSolar USA Inc,Mono-c-Si,0,450.0,428.4,1.81,,,108.0,14.07,39.47,13.19,34.13,0.006218940000000001,-0.090050805,43.4,1.3961002069635262,14.07880318329101,7.2110797615844664e-12,0.06250716110116608,99.90428788881643,12.870605810442969,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-108-455W,GermanSolar USA Inc,Mono-c-Si,0,455.0,433.3,1.81,,,108.0,14.21,39.53,13.31,34.18,0.00628082,-0.09018769500000001,43.4,1.3987503544006115,14.219204653292868,7.353713535481516e-12,0.06201288500051455,95.73452327561304,12.96448240889435,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-525W-HC,GermanSolar USA Inc,Mono-c-Si,0,525.0,496.6,2.38,,,144.0,13.61,49.05,12.73,41.24,0.00632865,-0.1142865,43.3,1.7641922755291586,13.628489117554103,1.1154592868157561e-11,0.1755895250224813,129.25297449726352,14.78847234273038,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-530W-HC,GermanSolar USA Inc,Mono-c-Si,0,530.0,501.5,2.38,,,144.0,13.68,49.2,12.76,41.53,0.0063612,-0.11463600000000002,43.3,1.7753288468607427,13.69916758102038,1.2222482252058259e-11,0.16025893178494627,114.37761435504926,15.615020016548181,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-535W-HC,GermanSolar USA Inc,Mono-c-Si,0,535.0,506.3,2.38,,,144.0,13.75,49.35,12.79,41.82,0.00639375,-0.11498550000000002,43.3,1.7865071458818185,13.769402749888938,1.338628161282389e-11,0.14498889436631174,102.74818324705225,16.442512800151512,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-540W-HC,GermanSolar USA Inc,Mono-c-Si,0,540.0,511.2,2.38,,,144.0,13.82,49.51,12.82,42.12,0.006426300000000001,-0.1153583,43.3,1.7981212353413962,13.83918243428634,1.4660894528328736e-11,0.12967207087666927,93.42234646066107,17.27544755524527,-0.3179,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM-545W-HC,GermanSolar USA Inc,Mono-c-Si,0,545.0,516.0,2.38,,,144.0,13.89,49.69,12.85,42.41,0.0064588499999999995,-0.11577770000000001,43.3,1.8099384709296031,13.908907114885677,1.591206540902439e-11,0.11686826768572776,85.85658095141243,18.026487126210615,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-550W-HC,GermanSolar USA Inc,Mono-c-Si,0,550.0,520.9,2.38,,,144.0,13.97,49.88,12.88,42.71,0.006496050000000001,-0.11622040000000002,43.3,1.8228445770794601,13.988580802638975,1.7438224437776937e-11,0.10378724094198416,78.03256865603304,18.872318248856935,-0.3179,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM-555W-HC,GermanSolar USA Inc,Mono-c-Si,0,555.0,525.7,2.38,,,144.0,14.04,50.02,12.91,43.0,0.0065286,-0.11654660000000003,43.3,1.8340108114653382,14.056973986581788,1.911432019541466e-11,0.08796137868325728,72.75708344050075,19.729373106671716,-0.3179,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-144-560W,GermanSolar USA Inc,Mono-c-Si,0,560.0,532.3,2.41,,,144.0,13.16,53.15,12.58,44.53,0.00581672,-0.12126172499999999,43.4,1.8360291953532895,13.161823346814284,3.516569170961757e-12,0.2228055007347651,1608.098053528865,6.874600001876955,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-144-565W,GermanSolar USA Inc,Mono-c-Si,0,565.0,537.1,2.41,,,144.0,13.21,53.34,12.68,44.55,0.0058388200000000015,-0.12169521000000001,43.4,1.8402069694358563,13.21000299208596,3.4079857146274e-12,0.22649990249326227,999997.2207590926,6.554624515869733,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-144-570W,GermanSolar USA Inc,Mono-c-Si,0,570.0,542.0,2.41,,,144.0,13.26,53.53,12.79,44.58,0.00586092,-0.122128695,43.4,1.8482332027546098,13.260003065318784,3.5007375967071985e-12,0.21713362823741306,939283.3503323469,6.758017935354139,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-144-575W,GermanSolar USA Inc,Mono-c-Si,0,575.0,546.9,2.41,,,144.0,13.3,53.73,12.84,44.79,0.0058786,-0.122584995,43.4,1.8565090086212215,13.300002966201275,3.587174421427025e-12,0.2098112101711464,940765.4074303267,6.9467583416956105,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-144-580W,GermanSolar USA Inc,Mono-c-Si,0,580.0,551.8,2.41,,,144.0,13.35,53.92,12.89,45.0,0.005900700000000001,-0.12301848,43.4,1.835559726154498,13.350006103486571,2.3333252516060437e-12,0.24164251566225,528539.4606800639,3.1710030686043003,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-144-590W,GermanSolar USA Inc,Mono-c-Si,0,590.0,561.5,2.41,,,144.0,13.45,54.31,12.99,45.42,0.005944900000000001,-0.123908265,43.4,1.8792889852214585,13.450347230397664,3.782336152460712e-12,0.22832802222583676,8844.306407492031,7.318049386968638,-0.29641,N,2025.7.3,6/23/2025,4.0,first_pass +GermanSolar USA Inc GSM10-144-595W,GermanSolar USA Inc,Mono-c-Si,0,595.0,566.4,2.41,,,144.0,13.5,54.5,13.04,45.63,0.005967000000000001,-0.12434175,43.4,1.886848153881099,13.500050092009145,3.855454039843279e-12,0.19098436248454853,51471.073282633886,7.453403765564799,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-144-600W,GermanSolar USA Inc,Mono-c-Si,0,600.0,571.3,2.41,,,144.0,13.55,54.7,13.09,45.84,0.005989100000000001,-0.12479805000000001,43.4,1.894469215570829,13.55000268808209,3.9113431452206215e-12,0.18724057821254686,943839.8222372305,7.548006611602357,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM10-144-605W,GermanSolar USA Inc,Mono-c-Si,0,605.0,576.1,2.41,,,144.0,13.6,54.89,13.14,46.05,0.006011200000000001,-0.125231535,43.4,1.9019771548174536,13.600002628553707,3.981443745398253e-12,0.1825398356855059,944454.9559581314,7.673056073473081,-0.29641,N,2025.7.3,6/23/2025,2.0,first_pass +GermanSolar USA Inc GSM-640W-H,GermanSolar USA Inc,Mono-c-Si,0,640.0,605.2,2.91,,,132.0,18.31,44.9,17.07,37.5,0.01003388,-0.1097356,43.2,1.6365454711861271,18.340460935062957,2.1609853635141133e-11,0.1328315411617436,79.84474299944692,12.589747194094764,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-645W-H,GermanSolar USA Inc,Mono-c-Si,0,645.0,610.1,2.91,,,132.0,18.35,44.9,17.11,37.7,0.010055800000000002,-0.1097356,43.2,1.6407498325716232,18.377566786324927,2.3227247146531256e-11,0.11914996290254794,79.31290210383654,13.235456268312904,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-650W-H,GermanSolar USA Inc,Mono-c-Si,0,650.0,614.9,2.91,,,132.0,18.39,45.0,17.16,37.9,0.01007772,-0.10998000000000001,43.2,1.6463177370088442,18.41525514693399,2.4044441034439787e-11,0.11146452147967482,81.16494274199674,13.532699846491086,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-655W-H,GermanSolar USA Inc,Mono-c-Si,0,655.0,619.8,2.91,,,132.0,18.43,45.2,17.2,38.1,0.01009964,-0.1104688,43.2,1.6541894318660917,18.454724717376372,2.432125017172606e-11,0.10962882657600825,81.71819510857529,13.618136867612888,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-660W-H,GermanSolar USA Inc,Mono-c-Si,0,660.0,624.6,2.91,,,132.0,18.47,45.4,17.24,38.3,0.01012156,-0.1109576,43.2,1.6620599280887665,18.494200707414524,2.45985120239348e-11,0.10780212548502771,82.27467190393274,13.70264117330283,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-665W-H,GermanSolar USA Inc,Mono-c-Si,0,665.0,629.5,2.91,,,132.0,18.51,45.6,17.28,38.5,0.010143480000000002,-0.1114464,43.2,1.6699292255238738,18.533683041171905,2.487620863525466e-11,0.10598434929352157,82.83439174027768,13.786234587298615,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +GermanSolar USA Inc GSM-670W-H,GermanSolar USA Inc,Mono-c-Si,0,670.0,634.3,2.91,,,132.0,18.55,45.8,17.32,38.7,0.0101654,-0.1119352,43.2,1.6777973418538568,18.573171644816075,2.515432844757002e-11,0.10417543042179214,83.39737011334866,13.868926672395636,-0.3213,N,2025.7.3,6/23/2025,4.0,bootstrapping +Gintech Energy GTE 200M,Gintech Energy,Multi-c-Si,0,200.0,178.3,1.68165,1.665,1.01,60.0,8.01,35.9,7.38,29.3,0.00338022,-0.13286589999999998,43.1,1.651352548322317,8.023448930158278,2.8153166248011238e-09,0.24765553078383554,147.50033131610164,17.68438229620826,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 205M,Gintech Energy,Multi-c-Si,0,205.0,182.8,1.68165,1.665,1.01,60.0,8.02,35.9,7.39,29.3,0.00338444,-0.13286589999999998,43.1,1.651248008849102,8.03340832987956,2.815317609046931e-09,0.24737105850792515,147.96151089086507,17.671975003727724,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 210M,Gintech Energy,Multi-c-Si,0,210.0,187.4,1.68165,1.665,1.01,60.0,8.04,35.92,7.4,29.32,0.00339288,-0.13293992,43.1,1.6534180840054522,8.054027087102707,2.865116353913197e-09,0.2460359994009122,141.0221775399925,17.82122763512425,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 215M,Gintech Energy,Multi-c-Si,0,215.0,192.0,1.68165,1.665,1.01,60.0,8.05,35.94,7.58,29.34,0.0033971,-0.13301394,43.1,1.6327392709467885,8.051390016452215,2.2120838503219115e-09,0.24999722620472514,1447.8135316579462,15.2591950473607,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 220M,Gintech Energy,Multi-c-Si,0,220.0,196.5,1.68165,1.665,1.01,60.0,8.08,36.06,7.58,29.58,0.00340976,-0.13345806000000002,43.1,1.646461211423739,8.083429072515091,2.467443967842182e-09,0.22683514473320315,534.4974937560047,16.272899141711296,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 225M,Gintech Energy,Multi-c-Si,0,225.0,201.1,1.68165,1.665,1.01,60.0,8.25,36.66,7.66,30.0,0.0034815000000000002,-0.13567865999999998,43.1,1.6814232978713786,8.259161855340174,2.7467322099380874e-09,0.23476916078828164,211.40334149408886,17.136015636147306,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 230M,Gintech Energy,Multi-c-Si,0,230.0,205.7,1.68165,1.665,1.01,60.0,8.31,36.9,7.77,30.3,0.0035068200000000003,-0.1365669,43.1,1.6890845004897075,8.315198128408651,2.671154757900956e-09,0.2202050636448518,352.03168775758905,16.77429092159559,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 235M,Gintech Energy,Multi-c-Si,0,235.0,210.3,1.68165,1.665,1.01,60.0,8.41,37.32,7.92,30.54,0.0035490200000000004,-0.13812132000000002,43.1,1.6977792078110876,8.411447373194578,2.382097952217059e-09,0.23744990166593077,1379.7139858328485,15.544911286422288,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintech Energy GTE 240M,Gintech Energy,Multi-c-Si,0,240.0,214.9,1.68165,1.665,1.01,60.0,8.46,37.5,7.97,30.72,0.0035701200000000004,-0.1387875,43.1,1.7067138550650085,8.46127910272281,2.4201500255568913e-09,0.23236427511643012,1536.8662584490648,15.637465347688416,-0.5417,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-120G6M,Gintung Energy,Multi-c-Si,0,120.0,106.9,0.9828720000000001,1.496,0.657,36.0,7.49,21.6,6.93,17.33,0.00160286,-0.07125840000000001,46.1,0.894542713863253,7.507942721627209,2.377082786700595e-10,0.23690509871578158,98.89354433589318,8.969778810762824,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-125G6M,Gintung Energy,Multi-c-Si,0,125.0,111.5,0.9828720000000001,1.496,0.657,36.0,7.89,21.58,7.28,17.19,0.00168846,-0.07119242,46.1,0.8913164946066807,7.912587865999474,2.3408472486467934e-10,0.24479246531030283,85.50664795447207,8.389538129851214,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-125G6S,Gintung Energy,Mono-c-Si,0,125.0,111.7,0.9828720000000001,1.496,0.657,36.0,8.01,21.55,7.23,17.29,0.00338823,-0.07320535,45.8,0.9209439338675995,8.048017914668925,5.210101366316825e-10,0.21554243701456696,45.41267100258701,11.938156869679421,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-130G6M,Gintung Energy,Multi-c-Si,0,130.0,116.0,0.9828720000000001,1.496,0.657,36.0,7.93,21.66,7.45,17.54,0.0016970199999999998,-0.07145634000000001,46.1,0.8945145715964087,7.936195939930058,2.3923110564451486e-10,0.19898460289731557,254.67454625360975,8.47028031975492,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-130G6S,Gintung Energy,Mono-c-Si,0,130.0,116.3,0.9828720000000001,1.496,0.657,36.0,8.11,21.96,7.44,17.48,0.0034305299999999993,-0.07459812,45.8,0.9254802433150733,8.137453792802729,3.8778893040857625e-10,0.2399475909776279,70.8818331366937,9.13292786488976,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-135G6M,Gintung Energy,Multi-c-Si,0,135.0,120.6,0.9828720000000001,1.496,0.657,36.0,8.26,22.1,7.64,17.68,0.0017676399999999998,-0.07290790000000001,46.1,0.9138760516144475,8.28058971320465,2.527936963871533e-10,0.22771087239315652,91.35105233175476,8.652539716967382,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-135G6S,Gintung Energy,Mono-c-Si,0,135.0,120.9,0.9828720000000001,1.496,0.657,36.0,8.27,22.15,7.7,17.54,0.0034982099999999994,-0.07524355,45.8,0.92326728219885,8.284441099054325,3.097524655735401e-10,0.25146456476211143,144.00651379767768,6.9515297984246125,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-140G6M,Gintung Energy,Multi-c-Si,0,140.0,125.2,0.9828720000000001,1.496,0.657,36.0,8.57,22.25,7.89,17.75,0.0018339799999999998,-0.07340275,46.1,0.9208728977549553,8.596345682188572,2.6641198248641765e-10,0.22841478507540725,74.3011640444459,8.805535915522636,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-140G6S,Gintung Energy,Mono-c-Si,0,140.0,125.5,0.9828720000000001,1.496,0.657,36.0,8.47,22.25,7.95,17.62,0.00358281,-0.07558325,45.8,0.9235988217428076,8.476444206101016,2.899258378643117e-10,0.24631822863735905,323.7506945621889,6.149804098862431,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-145G6M49,Gintung Energy,Multi-c-Si,0,145.0,127.4,0.9863460000000002,1.481,0.666,36.0,8.66,22.32,8.14,17.81,0.0056991459999999996,-0.07649064,50.0,0.9414013341470845,8.664739439118325,4.346298725770758e-10,0.21918158700494159,400.49331326356264,8.233728596866436,-0.4607,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-145G6S49,Gintung Energy,Mono-c-Si,0,145.0,126.8,0.9863460000000002,1.481,0.666,36.0,8.64,22.38,8.2,17.68,0.006298560000000001,-0.07676340000000001,51.4,0.9350694836360546,8.640002021432517,3.484069181472486e-10,0.23364692027035086,999991.11672188,6.140552323348906,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-150G6M49,Gintung Energy,Multi-c-Si,0,150.0,131.9,0.9863460000000002,1.481,0.666,36.0,8.81,22.4,8.37,17.92,0.0057978610000000005,-0.0767648,50.0,0.9460929957672692,8.810001733511612,4.59705817241361e-10,0.19649319741186277,999999.8947306364,8.558257234969055,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-150G6S49,Gintung Energy,Mono-c-Si,0,150.0,131.3,0.9863460000000002,1.481,0.666,36.0,8.78,22.48,8.43,17.79,0.00640062,-0.0771064,51.4,0.9453085580392434,8.780001714447488,4.1277395770140205e-10,0.1950045071332513,999862.2030910043,7.468500434967338,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-155G6M49,Gintung Energy,Multi-c-Si,0,155.0,136.5,0.9863460000000002,1.481,0.666,36.0,8.98,22.53,8.58,18.07,0.0059097379999999994,-0.07721031,50.0,0.9553381406272173,8.980001559096785,5.142686781706966e-10,0.17338282688696882,999994.1583656118,9.37949014438951,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-155G6S49,Gintung Energy,Mono-c-Si,0,155.0,135.9,0.9863460000000002,1.481,0.666,36.0,8.96,22.58,8.64,17.94,0.006531840000000001,-0.0774494,51.4,0.9535397263854585,8.960165392422534,4.656088499799559e-10,0.1686347566252125,9135.750328921016,8.345294627088586,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-175G6M,Gintung Energy,Multi-c-Si,0,175.0,155.9,1.3044909999999998,1.319,0.989,48.0,8.03,29.29,7.48,23.41,0.0071467,-0.102515,45.9,1.2919191894192756,8.04009246912111,1.1276481392075323e-09,0.29070593400375105,231.29821120702923,14.956000009675245,-0.483,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-175G6S,Gintung Energy,Mono-c-Si,0,175.0,155.2,1.3044909999999998,1.319,0.989,48.0,8.24,29.57,7.46,23.51,0.0074984,-0.1055649,45.1,1.3700857282800178,8.272935902886902,3.3311398060459124e-09,0.29095416182324435,72.79179380681369,22.961164669527086,-0.522,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-180G6M,Gintung Energy,Multi-c-Si,0,180.0,160.5,1.3044909999999998,1.319,0.989,48.0,8.15,29.51,7.61,23.68,0.0072534999999999995,-0.103285,45.9,1.3030390895358681,8.15811693632241,1.175840169182901e-09,0.2739097178030264,275.0256478031274,15.204120356423708,-0.483,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-180G6S,Gintung Energy,Mono-c-Si,0,180.0,159.7,1.3044909999999998,1.319,0.989,48.0,8.3,29.73,7.58,23.82,0.007553,-0.1061361,45.1,1.3771879914348033,8.32363787510862,3.3713133584625393e-09,0.2620169685479102,92.00243352300168,22.986506327973643,-0.522,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-185G6M,Gintung Energy,Multi-c-Si,0,185.0,165.1,1.3044909999999998,1.319,0.989,48.0,8.23,29.76,7.79,23.75,0.007324700000000001,-0.10416,45.9,1.3027463535772907,8.262766200277541,9.910144502401103e-10,0.29305366266981064,999999.8979369771,13.448216126103297,-0.483,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-185G6S,Gintung Energy,Mono-c-Si,0,185.0,164.3,1.3044909999999998,1.319,0.989,48.0,8.33,29.9,7.63,24.28,0.0075803,-0.10674299999999999,45.1,1.394223765589361,8.347893303528426,3.906508470306026e-09,0.21177638985181177,98.58986097585927,24.45444435700252,-0.522,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-190G6M,Gintung Energy,Multi-c-Si,0,190.0,167.8,1.4069699999999998,1.458,0.965,54.0,7.87,32.85,7.56,25.18,0.014402100000000001,-0.1363275,43.9,1.6216822441154595,8.121296059070108,1.2948873859338686e-08,0.4413749826580069,999999.9692987367,17.38327700244513,-0.572,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-190G6M68,Gintung Energy,Multi-c-Si,0,190.0,170.0,1.3044909999999998,1.319,0.989,48.0,8.35,29.81,7.97,23.84,0.0017869,-0.09834319,46.1,1.2228311831388723,8.350002297260835,2.1603175269967582e-10,0.274977182363593,999997.8656251959,7.107754925438037,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-190G6S,Gintung Energy,Mono-c-Si,0,190.0,169.8,1.4069699999999998,1.458,0.965,54.0,8.01,32.83,7.53,25.25,0.010893600000000002,-0.12179929999999999,44.2,1.4986199714478534,8.048127245785267,2.4642310777201365e-09,0.4607234619945249,999999.9721910768,14.995939817755291,-0.514,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-190G6S68,Gintung Energy,Mono-c-Si,0,190.0,170.4,1.3044909999999998,1.319,0.989,48.0,8.51,29.71,8.05,23.61,0.0035997299999999998,-0.10092487000000001,45.8,1.2315468609414988,8.520383199649705,2.84105646534794e-10,0.3146027752007492,999999.1317780107,5.903987245443975,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-190G6M68,Gintung Energy,Multi-c-Si,0,190.0,170.0,1.3044909999999998,1.319,0.989,48.0,8.35,29.81,7.97,23.84,0.0017869,-0.09834319,46.1,1.2228311831388723,8.350002297260835,2.1603175269967582e-10,0.274977182363593,999997.8656251959,7.107754925438037,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-190G6S68,Gintung Energy,Mono-c-Si,0,190.0,170.4,1.3044909999999998,1.319,0.989,48.0,8.51,29.71,8.05,23.61,0.0035997299999999998,-0.10092487000000001,45.8,1.2315468609414988,8.520383199649705,2.84105646534794e-10,0.3146027752007492,999999.1317780107,5.903987245443975,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-195G6M,Gintung Energy,Multi-c-Si,0,195.0,172.4,1.4069699999999998,1.458,0.965,54.0,8.11,32.94,7.63,25.59,0.015408999999999999,-0.13834799999999997,43.9,1.6508306096145067,8.18535927361424,1.7672631299431593e-08,0.38117738595892064,999999.5190105189,18.886773186595345,-0.572,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-195G6M68,Gintung Energy,Multi-c-Si,0,195.0,174.6,1.3044909999999998,1.319,0.989,48.0,8.48,29.87,8.16,23.9,0.00181472,-0.09854113000000002,46.1,1.2303686641128966,8.48019469639336,2.4253260204621637e-10,0.23644231430596196,10298.295696799232,7.973425519616597,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-195G6S,Gintung Energy,Mono-c-Si,0,195.0,174.4,1.4069699999999998,1.458,0.965,54.0,8.21,32.95,7.71,25.31,0.011165600000000001,-0.1222445,44.2,1.5031357202959208,8.241897809831642,2.488427269063386e-09,0.4566185727464665,999999.9722696616,14.861051557903329,-0.514,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-195G6S68,Gintung Energy,Mono-c-Si,0,195.0,175.0,1.3044909999999998,1.319,0.989,48.0,8.63,29.82,8.24,23.67,0.0036504900000000006,-0.10129854,45.8,1.241589728917461,8.630002415976584,3.2011069368506835e-10,0.279721845847649,999975.148650754,6.815917530476357,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-195G6M68,Gintung Energy,Multi-c-Si,0,195.0,174.6,1.3044909999999998,1.319,0.989,48.0,8.48,29.87,8.16,23.9,0.00181472,-0.09854113000000002,46.1,1.2303686641128966,8.48019469639336,2.4253260204621637e-10,0.23644231430596196,10298.295696799232,7.973425519616597,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-195G6S68,Gintung Energy,Mono-c-Si,0,195.0,175.0,1.3044909999999998,1.319,0.989,48.0,8.63,29.82,8.24,23.67,0.0036504900000000006,-0.10129854,45.8,1.241589728917461,8.630002415976584,3.2011069368506835e-10,0.279721845847649,999975.148650754,6.815917530476357,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-200G6M,Gintung Energy,Multi-c-Si,0,200.0,176.9,1.4069699999999998,1.458,0.965,54.0,8.31,33.03,7.85,25.5,0.015789,-0.13872600000000002,43.9,1.6631048575048242,8.310002967438606,1.9693297803634925e-08,0.34610301023278667,999999.9600719666,19.82327340929346,-0.572,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-200G6M68,Gintung Energy,Multi-c-Si,0,200.0,175.9,1.3044909999999998,1.319,0.989,48.0,8.65,29.95,8.31,24.07,0.005692565,-0.10263865,50.0,1.2749187802393485,8.650178456799363,5.427063522575036e-10,0.21003971692670323,10180.95679961595,10.192328992567118,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-200G6S,Gintung Energy,Mono-c-Si,0,200.0,179.0,1.4069699999999998,1.458,0.965,54.0,8.24,33.53,7.89,25.38,0.011206400000000002,-0.12439630000000002,44.2,1.53715350889198,8.24000346364758,2.771023264409965e-09,0.417528498560022,999999.9457513217,15.887271021678936,-0.514,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-200G6S68,Gintung Energy,Mono-c-Si,0,200.0,175.2,1.3044909999999998,1.319,0.989,48.0,8.77,29.93,8.39,23.84,0.006393330000000001,-0.10265990000000001,51.4,1.260266788733436,8.770002539968301,4.255636841406241e-10,0.254354860609887,878575.7264521488,7.744581992111189,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-200G6M68,Gintung Energy,Multi-c-Si,0,200.0,175.9,1.3044909999999998,1.319,0.989,48.0,8.65,29.95,8.31,24.07,0.005692565,-0.10263865,50.0,1.2749187802393485,8.650178456799363,5.427063522575036e-10,0.21003971692670323,10180.95679961595,10.192328992567118,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-200G6S68,Gintung Energy,Mono-c-Si,0,200.0,175.2,1.3044909999999998,1.319,0.989,48.0,8.77,29.93,8.39,23.84,0.006393330000000001,-0.10265990000000001,51.4,1.260266788733436,8.770002539968301,4.255636841406241e-10,0.254354860609887,878575.7264521488,7.744581992111189,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-205G6M,Gintung Energy,Multi-c-Si,0,205.0,181.5,1.4069699999999998,1.458,0.965,54.0,8.61,33.58,7.93,25.87,0.016359,-0.141036,43.9,1.6864585714190743,8.623086793126111,1.913178180438868e-08,0.4026112167461379,264.8866618843881,19.181215786400244,-0.572,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-205G6M68,Gintung Energy,Multi-c-Si,0,205.0,180.5,1.3044909999999998,1.319,0.989,48.0,8.83,30.03,8.46,24.23,0.005811022999999999,-0.10291281000000001,50.0,1.2787193741864407,8.830002205316712,5.58212014819267e-10,0.20606208169224247,825440.2474575088,10.259028538771858,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-205G6S,Gintung Energy,Mono-c-Si,0,205.0,183.6,1.4069699999999998,1.458,0.965,54.0,8.32,33.64,7.93,25.87,0.011315200000000003,-0.12480440000000001,44.2,1.550650668014825,8.320092649023467,3.1509442425250562e-09,0.3810547594311426,34226.70100045599,17.03703545072539,-0.514,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-205G6S68,Gintung Energy,Mono-c-Si,0,205.0,179.7,1.3044909999999998,1.319,0.989,48.0,8.91,30.04,8.54,24.0,0.00649539,-0.10303720000000001,51.4,1.2678852519355732,8.910002095089743,4.5723449657011153e-10,0.23492251534264214,999997.9188761013,8.234332443032573,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-205G6M68,Gintung Energy,Multi-c-Si,0,205.0,180.5,1.3044909999999998,1.319,0.989,48.0,8.83,30.03,8.46,24.23,0.005811022999999999,-0.10291281000000001,50.0,1.2787193741864407,8.830002205316712,5.58212014819267e-10,0.20606208169224247,825440.2474575088,10.259028538771858,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-205G6S68,Gintung Energy,Mono-c-Si,0,205.0,179.7,1.3044909999999998,1.319,0.989,48.0,8.91,30.04,8.54,24.0,0.00649539,-0.10303720000000001,51.4,1.2678852519355732,8.910002095089743,4.5723449657011153e-10,0.23492251534264214,999997.9188761013,8.234332443032573,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-210G6M,Gintung Energy,Multi-c-Si,0,210.0,186.1,1.4069699999999998,1.458,0.965,54.0,8.65,33.61,8.02,26.19,0.016435,-0.141162,43.9,1.6943236219774949,8.65605416636612,2.0843114253835773e-08,0.3553534944131982,507.72672792204844,20.005321030295054,-0.572,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-210G6M68,Gintung Energy,Multi-c-Si,0,210.0,185.0,1.3044909999999998,1.319,0.989,48.0,8.99,30.14,8.63,24.33,0.005916319,-0.10328978,50.0,1.2852377129279031,8.99017215888884,5.875173700094973e-10,0.19306969694105935,10082.043901663583,10.557185636458096,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-210G6S,Gintung Energy,Mono-c-Si,0,210.0,188.2,1.4069699999999998,1.458,0.965,54.0,8.35,33.68,7.98,26.33,0.011356000000000002,-0.12495279999999999,44.2,1.5496145824154486,8.51124222146153,3.0963163072591517e-09,0.38238165926164114,999999.9738862311,16.673719642055545,-0.514,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-210G6S68,Gintung Energy,Mono-c-Si,0,210.0,184.3,1.3044909999999998,1.319,0.989,48.0,9.05,30.14,8.71,24.11,0.006597450000000001,-0.1033802,51.4,1.2754428864845395,9.05000191818896,4.941186061029586e-10,0.21176269352198568,999994.5336914114,8.779731122332258,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-210G6M68,Gintung Energy,Multi-c-Si,0,210.0,185.0,1.3044909999999998,1.319,0.989,48.0,8.99,30.14,8.63,24.33,0.005916319,-0.10328978,50.0,1.2852377129279031,8.99017215888884,5.875173700094973e-10,0.19306969694105935,10082.043901663583,10.557185636458096,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-210G6S68,Gintung Energy,Mono-c-Si,0,210.0,184.3,1.3044909999999998,1.319,0.989,48.0,9.05,30.14,8.71,24.11,0.006597450000000001,-0.1033802,51.4,1.2754428864845395,9.05000191818896,4.941186061029586e-10,0.21176269352198568,999994.5336914114,8.779731122332258,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-215G6M,Gintung Energy,Multi-c-Si,0,215.0,192.0,1.611081,1.629,0.989,60.0,7.96,36.39,7.41,29.02,0.00170344,-0.12005061000000002,46.1,1.496952528338198,7.974579306221921,2.1636757574564938e-10,0.4038414817331339,220.48913072101288,7.597280855584417,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-215G6M68,Gintung Energy,Multi-c-Si,0,215.0,189.6,1.3044909999999998,1.319,0.989,48.0,9.14,30.27,8.79,24.46,0.006015034,-0.10373529000000001,50.0,1.2925618915688193,9.140163441411449,6.169345837767864e-10,0.18025849238033761,10080.54570059156,10.8471480910498,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-215G6M69,Gintung Energy,Multi-c-Si,0,215.0,192.5,1.464709,1.481,0.989,54.0,8.71,33.69,8.08,26.61,0.0018639400000000001,-0.11114331,46.1,1.3807830172950333,8.730645674601995,2.1577885125664764e-10,0.3793483346657465,160.03954349202803,6.8088759891571025,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-215G6S,Gintung Energy,Mono-c-Si,0,215.0,192.4,1.611081,1.629,0.989,60.0,8.07,36.4,7.45,28.88,0.00341361,-0.12365079999999999,45.8,1.5258607266190178,8.092140172589174,3.4251795614618717e-10,0.4148113887280662,151.19702912385512,8.065749037109345,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-215G6S68,Gintung Energy,Mono-c-Si,0,215.0,188.8,1.3044909999999998,1.319,0.989,48.0,9.18,30.26,8.87,24.24,0.0066922200000000005,-0.10379180000000002,51.4,1.2842327671555198,9.180170441829894,5.364819816931515e-10,0.1870534058616639,10074.788619369476,9.382223115455174,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-215G6S69,Gintung Energy,Mono-c-Si,0,215.0,192.9,1.464709,1.481,0.989,54.0,8.47,33.77,8.09,26.58,0.00358281,-0.11471669000000002,45.8,1.4007187045061673,8.470003107523414,2.867170640177865e-10,0.35128705799451954,957003.7002083163,6.032061051117801,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-215G6M68,Gintung Energy,Multi-c-Si,0,215.0,189.6,1.3044909999999998,1.319,0.989,48.0,9.14,30.27,8.79,24.46,0.006015034,-0.10373529000000001,50.0,1.2925618915688193,9.140163441411449,6.169345837767864e-10,0.18025849238033761,10080.54570059156,10.8471480910498,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-215G6M69,Gintung Energy,Multi-c-Si,0,215.0,192.5,1.464709,1.481,0.989,54.0,8.71,33.69,8.08,26.61,0.0018639400000000001,-0.11114331,46.1,1.3807830172950333,8.730645674601995,2.1577885125664764e-10,0.3793483346657465,160.03954349202803,6.8088759891571025,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-215G6S68,Gintung Energy,Mono-c-Si,0,215.0,188.8,1.3044909999999998,1.319,0.989,48.0,9.18,30.26,8.87,24.24,0.0066922200000000005,-0.10379180000000002,51.4,1.2842327671555198,9.180170441829894,5.364819816931515e-10,0.1870534058616639,10074.788619369476,9.382223115455174,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-215G6S69,Gintung Energy,Mono-c-Si,0,215.0,192.9,1.464709,1.481,0.989,54.0,8.47,33.77,8.09,26.58,0.00358281,-0.11471669000000002,45.8,1.4007187045061673,8.470003107523414,2.867170640177865e-10,0.35128705799451954,957003.7002083163,6.032061051117801,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-220G6M,Gintung Energy,Multi-c-Si,0,220.0,196.5,1.611081,1.629,0.989,60.0,8.1,36.57,7.56,29.11,0.0017334,-0.12064443000000002,46.1,1.5007425713408113,8.112542630618726,2.083466758052853e-10,0.4071621534335231,262.9443503625407,7.110895730342556,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-220G6M68,Gintung Energy,Multi-c-Si,0,220.0,194.2,1.3044909999999998,1.319,0.989,48.0,9.29,30.4,8.95,24.58,0.006113748999999999,-0.1041808,50.0,1.2996098334356443,9.29015594536625,6.442039986632366e-10,0.16896906055976957,10065.94677700079,11.089847027739925,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-220G6M69,Gintung Energy,Multi-c-Si,0,220.0,197.1,1.464709,1.481,0.989,54.0,8.75,33.75,8.24,26.71,0.0018725,-0.11134125000000002,46.1,1.3742219331269974,8.754047771779149,1.879829805235945e-10,0.3698415846740825,799.4806688287782,5.538408819625509,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-220G6S,Gintung Energy,Mono-c-Si,0,220.0,197.0,1.611081,1.629,0.989,60.0,8.21,36.53,7.59,28.99,0.00347283,-0.12409241,45.8,1.5303602111199468,8.231107859230743,3.4391248369091235e-10,0.4081035870184303,158.7338080251887,7.946502185674413,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-220G6S68,Gintung Energy,Mono-c-Si,0,220.0,193.4,1.3044909999999998,1.319,0.989,48.0,9.32,30.34,9.03,24.36,0.006794280000000001,-0.10406620000000001,51.4,1.2904809642577673,9.320001551447602,5.739639102333648e-10,0.16632105550103574,999999.1345575738,9.84728590722238,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-220G6S69,Gintung Energy,Mono-c-Si,0,220.0,197.5,1.464709,1.481,0.989,54.0,8.61,33.86,8.25,26.67,0.0036420299999999997,-0.11502242,45.8,1.4073982934735383,8.610270253967814,3.064407729905011e-10,0.3288058139883073,10475.475378786805,6.462086795273264,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-220G6M68,Gintung Energy,Multi-c-Si,0,220.0,194.2,1.3044909999999998,1.319,0.989,48.0,9.29,30.4,8.95,24.58,0.006113748999999999,-0.1041808,50.0,1.2996098334356443,9.29015594536625,6.442039986632366e-10,0.16896906055976957,10065.94677700079,11.089847027739925,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-220G6M69,Gintung Energy,Multi-c-Si,0,220.0,197.1,1.464709,1.481,0.989,54.0,8.75,33.75,8.24,26.71,0.0018725,-0.11134125000000002,46.1,1.3742219331269974,8.754047771779149,1.879829805235945e-10,0.3698415846740825,799.4806688287782,5.538408819625509,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-220G6S68,Gintung Energy,Mono-c-Si,0,220.0,193.4,1.3044909999999998,1.319,0.989,48.0,9.32,30.34,9.03,24.36,0.006794280000000001,-0.10406620000000001,51.4,1.2904809642577673,9.320001551447602,5.739639102333648e-10,0.16632105550103574,999999.1345575738,9.84728590722238,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-220G6S69,Gintung Energy,Mono-c-Si,0,220.0,197.5,1.464709,1.481,0.989,54.0,8.61,33.86,8.25,26.67,0.0036420299999999997,-0.11502242,45.8,1.4073982934735383,8.610270253967814,3.064407729905011e-10,0.3288058139883073,10475.475378786805,6.462086795273264,-0.4684,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-225G6M,Gintung Energy,Multi-c-Si,0,225.0,201.1,1.611081,1.629,0.989,60.0,8.21,36.75,7.71,29.19,0.00175694,-0.12123825,46.1,1.5015318167957359,8.216765823480555,1.9118308823745538e-10,0.41319089151037597,501.38731009804314,6.234959901349466,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-225G6M69,Gintung Energy,Multi-c-Si,0,225.0,197.9,1.464709,1.481,0.989,54.0,8.81,33.83,8.37,26.88,0.0057978610000000005,-0.11593541,50.0,1.4242243086801578,8.810002825397822,4.2565288275986193e-10,0.3203950093834055,999992.0367079233,7.883888460446184,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-225G6S,Gintung Energy,Mono-c-Si,0,225.0,201.6,1.611081,1.629,0.989,60.0,8.33,36.65,7.74,29.08,0.0035235899999999996,-0.12450005,45.8,1.5311005089348784,8.346442039341959,3.2837401734175785e-10,0.4042715455950763,204.81537868672328,7.401389898987034,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-225G6S69,Gintung Energy,Mono-c-Si,0,225.0,197.1,1.464709,1.481,0.989,54.0,8.75,33.92,8.38,26.85,0.006378750000000001,-0.11634560000000001,51.4,1.4251951389977509,8.750255355643837,4.032202405998821e-10,0.30456527002959854,10436.304096457668,7.295462749777448,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-225G6M69,Gintung Energy,Multi-c-Si,0,225.0,197.9,1.464709,1.481,0.989,54.0,8.81,33.83,8.37,26.88,0.0057978610000000005,-0.11593541,50.0,1.4242243086801578,8.810002825397822,4.2565288275986193e-10,0.3203950093834055,999992.0367079233,7.883888460446184,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-225G6S69,Gintung Energy,Mono-c-Si,0,225.0,197.1,1.464709,1.481,0.989,54.0,8.75,33.92,8.38,26.85,0.006378750000000001,-0.11634560000000001,51.4,1.4251951389977509,8.750255355643837,4.032202405998821e-10,0.30456527002959854,10436.304096457668,7.295462749777448,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-230G6M,Gintung Energy,Multi-c-Si,0,230.0,205.7,1.611081,1.629,0.989,60.0,8.32,36.87,7.85,29.3,0.00178048,-0.12163413000000001,46.1,1.503298305003124,8.322205599198202,1.8511653372451063e-10,0.4066223495496443,1533.8680613538309,5.829293542644299,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-230G6M69,Gintung Energy,Multi-c-Si,0,230.0,202.5,1.464709,1.481,0.989,54.0,8.92,33.93,8.51,27.03,0.005870251999999999,-0.11627811,50.0,1.433076963315315,8.92000260837423,4.6544117236162773e-10,0.2921487361585048,999998.180212422,8.558176741435267,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-230G6S,Gintung Energy,Mono-c-Si,0,230.0,206.2,1.611081,1.629,0.989,60.0,8.46,36.75,7.88,29.19,0.00357858,-0.12483975,45.8,1.5342456190679798,8.474170528665965,3.29085615651251e-10,0.3944746904084755,235.5068410444091,7.277903263481283,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-230G6S69,Gintung Energy,Mono-c-Si,0,230.0,201.6,1.464709,1.481,0.989,54.0,8.88,34.08,8.52,27.0,0.006473520000000001,-0.11689440000000001,51.4,1.433715737435477,8.880209307197523,4.216318464285763e-10,0.29060921218517194,12329.383550678094,7.555646654711085,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-230G6M69,Gintung Energy,Multi-c-Si,0,230.0,202.5,1.464709,1.481,0.989,54.0,8.92,33.93,8.51,27.03,0.005870251999999999,-0.11627811,50.0,1.433076963315315,8.92000260837423,4.6544117236162773e-10,0.2921487361585048,999998.180212422,8.558176741435267,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-230G6S69,Gintung Energy,Mono-c-Si,0,230.0,201.6,1.464709,1.481,0.989,54.0,8.88,34.08,8.52,27.0,0.006473520000000001,-0.11689440000000001,51.4,1.433715737435477,8.880209307197523,4.216318464285763e-10,0.29060921218517194,12329.383550678094,7.555646654711085,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-235G6M,Gintung Energy,Multi-c-Si,0,235.0,210.3,1.611081,1.629,0.989,60.0,8.45,37.06,8.01,29.34,0.0018082999999999997,-0.12226094000000003,46.1,1.50846637677594,8.45000344296162,1.8076265422087072e-10,0.40726169202294343,999999.8988028691,5.487582646356897,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-235G6M69,Gintung Energy,Multi-c-Si,0,235.0,207.0,1.464709,1.481,0.989,54.0,9.02,34.06,8.64,27.2,0.005936062,-0.11672362,50.0,1.4433790723766624,9.020193827055332,5.091664083867319e-10,0.2639799569667708,12284.789503062026,9.252684378442085,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-235G6S,Gintung Energy,Mono-c-Si,0,235.0,210.8,1.611081,1.629,0.989,60.0,8.58,36.88,8.03,29.27,0.00362934,-0.12528136,45.8,1.5351306161014744,8.58955639091887,3.127272925784522e-10,0.39366466140326656,353.4434401804079,6.699499307199607,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-235G6S69,Gintung Energy,Mono-c-Si,0,235.0,206.2,1.464709,1.481,0.989,54.0,9.0,34.13,8.65,27.17,0.006561,-0.11706590000000003,51.4,1.4399829808757953,9.000002378557717,4.578644366037789e-10,0.2640695600299157,999998.1805083347,8.15825005060196,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-235G6M69,Gintung Energy,Multi-c-Si,0,235.0,207.0,1.464709,1.481,0.989,54.0,9.02,34.06,8.64,27.2,0.005936062,-0.11672362,50.0,1.4433790723766624,9.020193827055332,5.091664083867319e-10,0.2639799569667708,12284.789503062026,9.252684378442085,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-235G6S69,Gintung Energy,Mono-c-Si,0,235.0,206.2,1.464709,1.481,0.989,54.0,9.0,34.13,8.65,27.17,0.006561,-0.11706590000000003,51.4,1.4399829808757953,9.000002378557717,4.578644366037789e-10,0.2640695600299157,999998.1805083347,8.15825005060196,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-240G6M69,Gintung Energy,Multi-c-Si,0,240.0,211.6,1.464709,1.481,0.989,54.0,9.14,34.19,8.77,27.37,0.006015034,-0.11716913,50.0,1.451835882721731,9.14021603187161,5.412338415284774e-10,0.24563753954085288,10392.669503542451,9.677290685862866,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-240G6M6A,Gintung Energy,Multi-c-Si,0,240.0,214.9,1.611081,1.629,0.989,60.0,8.55,37.18,8.16,29.42,0.0018297,-0.12265682000000001,46.1,1.517637857840352,8.550003222538498,1.9604618867642271e-10,0.376730980154213,999985.2889046718,6.076002649109771,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-240G6S69,Gintung Energy,Mono-c-Si,0,240.0,210.7,1.464709,1.481,0.989,54.0,9.14,34.19,8.78,27.33,0.006663060000000001,-0.1172717,51.4,1.4453938748041733,9.140217272012078,4.873069916670276e-10,0.24773317422761873,10421.500650074946,8.571167057921706,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-240G6S6A,Gintung Energy,Mono-c-Si,0,240.0,215.4,1.611081,1.629,0.989,60.0,8.68,37.01,8.17,29.38,0.00367164,-0.12572297,45.8,1.536230551867723,8.683782078761233,2.9775200956164503e-10,0.3893228890697554,893.5097824982751,6.158901336814258,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-240G6M69,Gintung Energy,Multi-c-Si,0,240.0,211.6,1.464709,1.481,0.989,54.0,9.14,34.19,8.77,27.37,0.006015034,-0.11716913,50.0,1.451835882721731,9.14021603187161,5.412338415284774e-10,0.24563753954085288,10392.669503542451,9.677290685862866,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-240G6M6A,Gintung Energy,Multi-c-Si,0,240.0,214.9,1.611081,1.629,0.989,60.0,8.55,37.18,8.16,29.42,0.0018297,-0.12265682000000001,46.1,1.517637857840352,8.550003222538498,1.9604618867642271e-10,0.376730980154213,999985.2889046718,6.076002649109771,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-240G6S69,Gintung Energy,Mono-c-Si,0,240.0,210.7,1.464709,1.481,0.989,54.0,9.14,34.19,8.78,27.33,0.006663060000000001,-0.1172717,51.4,1.4453938748041733,9.140217272012078,4.873069916670276e-10,0.24773317422761873,10421.500650074946,8.571167057921706,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-240G6S6A,Gintung Energy,Mono-c-Si,0,240.0,215.4,1.611081,1.629,0.989,60.0,8.68,37.01,8.17,29.38,0.00367164,-0.12572297,45.8,1.536230551867723,8.683782078761233,2.9775200956164503e-10,0.3893228890697554,893.5097824982751,6.158901336814258,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-245G6M,Gintung Energy,Multi-c-Si,0,245.0,218.4,1.956,1.956,1.0,72.0,7.68,43.39,7.18,34.13,0.0016435199999999999,-0.14314361,46.1,1.7671196516251808,7.690621784787104,1.6456743254595657e-10,0.5767874173564997,417.04178978033116,5.542175262289897,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-245G6M69,Gintung Energy,Multi-c-Si,0,245.0,216.2,1.464709,1.481,0.989,54.0,9.26,34.36,8.92,27.47,0.006094006,-0.11775172,50.0,1.4609217708877675,9.260204363073882,5.650948053131623e-10,0.22999037884401263,10421.306736332477,9.9451081880611,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-245G6M6A,Gintung Energy,Multi-c-Si,0,245.0,219.5,1.611081,1.629,0.989,60.0,8.67,37.31,8.29,29.56,0.0018553799999999998,-0.12308569000000003,46.1,1.5251006982383644,8.670003412163092,2.0580460813354906e-10,0.35949299163847154,913107.1882752307,6.3709499014396025,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-245G6S69,Gintung Energy,Mono-c-Si,0,245.0,215.3,1.464709,1.481,0.989,54.0,9.28,34.29,8.93,27.44,0.00676512,-0.1176147,51.4,1.4512108030556268,9.280002177099327,5.079251224996261e-10,0.23441003813340197,999996.2995645166,8.801450404037347,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-245G6S6A,Gintung Energy,Mono-c-Si,0,245.0,220.0,1.611081,1.629,0.989,60.0,8.81,37.14,8.31,29.49,0.0037266300000000003,-0.12616458,45.8,1.5401583103771312,8.811627309102109,2.9608864948036503e-10,0.38387802353145145,2078.2591394346005,5.976362762462339,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-245G6M69,Gintung Energy,Multi-c-Si,0,245.0,216.2,1.464709,1.481,0.989,54.0,9.26,34.36,8.92,27.47,0.006094006,-0.11775172,50.0,1.4609217708877675,9.260204363073882,5.650948053131623e-10,0.22999037884401263,10421.306736332477,9.9451081880611,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-245G6M6A,Gintung Energy,Multi-c-Si,0,245.0,219.5,1.611081,1.629,0.989,60.0,8.67,37.31,8.29,29.56,0.0018553799999999998,-0.12308569000000003,46.1,1.5251006982383644,8.670003412163092,2.0580460813354906e-10,0.35949299163847154,913107.1882752307,6.3709499014396025,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-245G6S69,Gintung Energy,Mono-c-Si,0,245.0,215.3,1.464709,1.481,0.989,54.0,9.28,34.29,8.93,27.44,0.00676512,-0.1176147,51.4,1.4512108030556268,9.280002177099327,5.079251224996261e-10,0.23441003813340197,999996.2995645166,8.801450404037347,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-245G6S6A,Gintung Energy,Mono-c-Si,0,245.0,220.0,1.611081,1.629,0.989,60.0,8.81,37.14,8.31,29.49,0.0037266300000000003,-0.12616458,45.8,1.5401583103771312,8.811627309102109,2.9608864948036503e-10,0.38387802353145145,2078.2591394346005,5.976362762462339,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-250G6M,Gintung Energy,Multi-c-Si,0,250.0,223.0,1.956,1.956,1.0,72.0,7.78,43.53,7.29,34.3,0.00166492,-0.14360547,46.1,1.7725447952873548,7.7884269775764565,1.6648448103577887e-10,0.5612257261284089,518.13797253393,5.522703354085683,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-250G6M6A,Gintung Energy,Multi-c-Si,0,250.0,220.0,1.611081,1.629,0.989,60.0,8.78,37.43,8.41,29.68,0.005778117999999999,-0.12827261,50.0,1.580932148222535,8.780264925384948,4.581635918264546e-10,0.32490151691784286,10767.787700448802,8.55977716718048,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-250G6M6B,Gintung Energy,Multi-c-Si,0,250.0,219.3,1.773277,1.793,0.989,66.0,8.25,40.95,7.81,32.01,0.005429325,-0.14033565,50.0,1.707779560477356,8.250004158999005,3.182143728543168e-10,0.5037197780533681,999999.9647045404,5.9354708913837415,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-250G6S6A,Gintung Energy,Mono-c-Si,0,250.0,219.1,1.611081,1.629,0.989,60.0,8.91,37.27,8.45,29.59,0.00649539,-0.1278361,51.4,1.5603376094184396,8.910003224464036,3.770339301821822e-10,0.3616010485709028,999999.9669951485,6.5557422517768815,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-250G6S6B,Gintung Energy,Mono-c-Si,0,250.0,218.4,1.773277,1.793,0.989,66.0,8.37,40.36,7.85,31.85,0.0061017300000000005,-0.13843480000000002,51.4,1.6862251764882248,8.37658066336895,3.3467893353875524e-10,0.4655410422829052,592.1257610183588,6.087882546914278,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-250G6M6A,Gintung Energy,Multi-c-Si,0,250.0,220.0,1.611081,1.629,0.989,60.0,8.78,37.43,8.41,29.68,0.005778117999999999,-0.12827261,50.0,1.580932148222535,8.780264925384948,4.581635918264546e-10,0.32490151691784286,10767.787700448802,8.55977716718048,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-250G6S6A,Gintung Energy,Mono-c-Si,0,250.0,219.1,1.611081,1.629,0.989,60.0,8.91,37.27,8.45,29.59,0.00649539,-0.1278361,51.4,1.5603376094184396,8.910003224464036,3.770339301821822e-10,0.3616010485709028,999999.9669951485,6.5557422517768815,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-255G6M,Gintung Energy,Multi-c-Si,0,255.0,227.5,1.956,1.956,1.0,72.0,7.89,43.69,7.4,34.46,0.00168846,-0.14413331000000001,46.1,1.7792089107366877,7.897599609090777,1.6935309775425028e-10,0.5499129825728557,570.9260031344558,5.545237221170612,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-255G6M6A,Gintung Energy,Multi-c-Si,0,255.0,224.6,1.611081,1.629,0.989,60.0,8.9,37.6,8.54,29.86,0.00585709,-0.1288552,50.0,1.590129488171085,8.900002752693394,4.787580877436793e-10,0.3090412715848719,999998.1594262071,8.826251824943462,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-255G6M6B,Gintung Energy,Multi-c-Si,0,255.0,223.9,1.773277,1.793,0.989,66.0,8.37,41.06,7.93,32.16,0.005508296999999999,-0.14071262,50.0,1.7146341950495094,8.370004066005707,3.3324295877687117e-10,0.48539691865301926,999999.841762249,6.207523633991615,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-255G6S,Gintung Energy,Mono-c-Si,0,255.0,228.0,1.956,1.956,1.0,72.0,7.98,43.85,7.42,34.37,0.0033755400000000002,-0.14895845,45.8,1.818180563027131,7.995894611223956,2.632681092943189e-10,0.5726298993032396,287.4928735754035,5.864140551063529,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-255G6S6A,Gintung Energy,Mono-c-Si,0,255.0,223.6,1.611081,1.629,0.989,60.0,9.02,37.35,8.58,29.72,0.006575580000000001,-0.12811050000000002,51.4,1.5676056749132812,9.020003045949844,4.05174046490929e-10,0.33742021217908336,999999.785412242,7.072517489547637,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-255G6S6B,Gintung Energy,Mono-c-Si,0,255.0,222.9,1.773277,1.793,0.989,66.0,8.46,40.62,7.95,32.08,0.006167340000000001,-0.13932660000000002,51.4,1.696144339597077,8.464594973416187,3.345525684554286e-10,0.45972172972948566,846.4136742818217,5.986779273855667,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-255G6M6A,Gintung Energy,Multi-c-Si,0,255.0,224.6,1.611081,1.629,0.989,60.0,8.9,37.6,8.54,29.86,0.00585709,-0.1288552,50.0,1.590129488171085,8.900002752693394,4.787580877436793e-10,0.3090412715848719,999998.1594262071,8.826251824943462,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-255G6S6A,Gintung Energy,Mono-c-Si,0,255.0,223.6,1.611081,1.629,0.989,60.0,9.02,37.35,8.58,29.72,0.006575580000000001,-0.12811050000000002,51.4,1.5676056749132812,9.020003045949844,4.05174046490929e-10,0.33742021217908336,999999.785412242,7.072517489547637,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-260G6M,Gintung Energy,Multi-c-Si,0,260.0,232.1,1.956,1.956,1.0,72.0,8.01,43.84,7.53,34.53,0.00171414,-0.14462816000000003,46.1,1.7818449845352218,8.015213286652832,1.6437786238585734e-10,0.5508769550585105,846.400021701308,5.156304786148223,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-260G6M6A,Gintung Energy,Multi-c-Si,0,260.0,229.1,1.611081,1.629,0.989,60.0,9.02,37.78,8.66,30.02,0.005936062,-0.12947206,50.0,1.5990934825457768,9.020251307577327,4.948320279202942e-10,0.29992546736660763,10765.10022080141,9.000481690606941,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-260G6M6B,Gintung Energy,Multi-c-Si,0,260.0,228.4,1.773277,1.793,0.989,66.0,8.48,41.21,8.04,32.34,0.0055806879999999994,-0.14122667,50.0,1.7230604201737088,8.480003981453807,3.479226740089477e-10,0.4691391015179296,999999.936384879,6.466055521981044,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-260G6S,Gintung Energy,Mono-c-Si,0,260.0,232.6,1.956,1.956,1.0,72.0,8.09,43.98,7.54,34.49,0.0034220699999999997,-0.14940006,45.8,1.8219196706242016,8.103487787108675,2.6184455836688185e-10,0.5634010164988427,337.9290596472901,5.693366138932079,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-260G6S6A,Gintung Energy,Mono-c-Si,0,260.0,228.1,1.611081,1.629,0.989,60.0,9.13,37.42,8.7,29.89,0.006655770000000001,-0.1283506,51.4,1.5747542925154674,9.130002854764898,4.3709292382788036e-10,0.31243436030200283,999999.4504986216,7.626768790283849,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-260G6S6B,Gintung Energy,Mono-c-Si,0,260.0,227.4,1.773277,1.793,0.989,66.0,8.58,40.73,8.06,32.26,0.00625482,-0.13970390000000002,51.4,1.7039150766952926,8.585187611620677,3.545174910307745e-10,0.4408191406087984,729.0889581511503,6.366352021061953,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-260G6M6A,Gintung Energy,Multi-c-Si,0,260.0,229.1,1.611081,1.629,0.989,60.0,9.02,37.78,8.66,30.02,0.005936062,-0.12947206,50.0,1.5990934825457768,9.020251307577327,4.948320279202942e-10,0.29992546736660763,10765.10022080141,9.000481690606941,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-260G6M6B,Gintung Energy,Multi-c-Si,0,260.0,228.4,1.773277,1.793,0.989,66.0,8.48,41.21,8.04,32.34,0.0055806879999999994,-0.14122667,50.0,1.7230604201737088,8.480003981453807,3.479226740089477e-10,0.4691391015179296,999999.936384879,6.466055521981044,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-260G6S6A,Gintung Energy,Mono-c-Si,0,260.0,228.1,1.611081,1.629,0.989,60.0,9.13,37.42,8.7,29.89,0.006655770000000001,-0.1283506,51.4,1.5747542925154674,9.130002854764898,4.3709292382788036e-10,0.31243436030200283,999999.4504986216,7.626768790283849,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-260G6S6B,Gintung Energy,Mono-c-Si,0,260.0,227.4,1.773277,1.793,0.989,66.0,8.58,40.73,8.06,32.26,0.00625482,-0.13970390000000002,51.4,1.7039150766952926,8.585187611620677,3.545174910307745e-10,0.4408191406087984,729.0889581511503,6.366352021061953,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-265G6M,Gintung Energy,Multi-c-Si,0,265.0,236.7,1.956,1.956,1.0,72.0,8.1,43.99,7.65,34.65,0.0017334,-0.14512301000000002,46.1,1.7838921611129865,8.10029729005859,1.580630896599514e-10,0.545788173449827,14870.661611797219,4.714688050351483,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-265G6M6A,Gintung Energy,Multi-c-Si,0,265.0,233.7,1.611081,1.629,0.989,60.0,9.15,37.91,8.78,30.18,0.006021615,-0.12991757,50.0,1.6056066513455798,9.150249536152193,5.094860747735123e-10,0.2924333362776214,10723.049166133747,9.131884762893968,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-265G6M6B,Gintung Energy,Multi-c-Si,0,265.0,232.9,1.773277,1.793,0.989,66.0,8.59,41.35,8.12,32.64,0.005653079,-0.14170645,50.0,1.7295483391183195,8.605967687756223,3.562013983001582e-10,0.4604726020779228,999999.9809719792,6.54305831927666,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-265G6S,Gintung Energy,Mono-c-Si,0,265.0,237.2,1.956,1.956,1.0,72.0,8.21,44.12,7.67,34.56,0.00347283,-0.14987564,45.8,1.8242854826805646,8.221019318999792,2.546840153965957e-10,0.5628374722031932,419.345050706984,5.323925343385227,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-265G6S6A,Gintung Energy,Mono-c-Si,0,265.0,232.7,1.611081,1.629,0.989,60.0,9.24,37.49,8.82,30.05,0.006735960000000001,-0.1285907,51.4,1.5816314903299602,9.24000267455696,4.692740703734775e-10,0.28922938534920667,999998.4226921456,8.14331450186984,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-265G6S6B,Gintung Energy,Mono-c-Si,0,265.0,231.9,1.773277,1.793,0.989,66.0,8.69,40.88,8.15,32.52,0.00633501,-0.14021840000000002,51.4,1.7160041740934828,8.697080436896671,3.8837887069273247e-10,0.4163416647191368,510.98689295812295,7.051855581940555,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-265G6M6A,Gintung Energy,Multi-c-Si,0,265.0,233.7,1.611081,1.629,0.989,60.0,9.15,37.91,8.78,30.18,0.006021615,-0.12991757,50.0,1.6056066513455798,9.150249536152193,5.094860747735123e-10,0.2924333362776214,10723.049166133747,9.131884762893968,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-265G6M6B,Gintung Energy,Multi-c-Si,0,265.0,232.9,1.773277,1.793,0.989,66.0,8.59,41.35,8.12,32.64,0.005653079,-0.14170645,50.0,1.7295483391183195,8.605967687756223,3.562013983001582e-10,0.4604726020779228,999999.9809719792,6.54305831927666,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-265G6S6A,Gintung Energy,Mono-c-Si,0,265.0,232.7,1.611081,1.629,0.989,60.0,9.24,37.49,8.82,30.05,0.006735960000000001,-0.1285907,51.4,1.5816314903299602,9.24000267455696,4.692740703734775e-10,0.28922938534920667,999998.4226921456,8.14331450186984,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-265G6S6B,Gintung Energy,Mono-c-Si,0,265.0,231.9,1.773277,1.793,0.989,66.0,8.69,40.88,8.15,32.52,0.00633501,-0.14021840000000002,51.4,1.7160041740934828,8.697080436896671,3.8837887069273247e-10,0.4163416647191368,510.98689295812295,7.051855581940555,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-270G6M,Gintung Energy,Multi-c-Si,0,270.0,241.3,1.956,1.956,1.0,72.0,8.19,44.15,7.75,34.87,0.0017526599999999999,-0.14565085000000003,46.1,1.792522310137771,8.20124597956315,1.6487768840155818e-10,0.5266436958193872,999999.9828805715,4.964231730309948,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-270G6M6A,Gintung Energy,Multi-c-Si,0,270.0,238.3,1.611081,1.629,0.989,60.0,9.28,38.03,8.9,30.34,0.006107167999999999,-0.13032881000000002,50.0,1.6119056637565903,9.280246586934087,5.260170654308726e-10,0.2840197793210061,10688.833650180804,9.28955903767435,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-270G6M6B,Gintung Energy,Multi-c-Si,0,270.0,237.5,1.773277,1.793,0.989,66.0,8.71,41.44,8.25,32.73,0.005732051,-0.14201488,50.0,1.7336603609855372,8.743150247981836,3.6361820950628187e-10,0.4515441287678857,999999.9810600412,6.585871333895374,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-270G6S,Gintung Energy,Mono-c-Si,0,270.0,241.8,1.956,1.956,1.0,72.0,8.34,44.27,7.8,34.62,0.0035278199999999997,-0.15038519,45.8,1.827711908228483,8.349884095389076,2.4976869996365896e-10,0.5645783465881532,476.37994911634956,5.021336308219829,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-270G6S6A,Gintung Energy,Mono-c-Si,0,270.0,237.2,1.611081,1.629,0.989,60.0,9.34,37.59,8.94,30.2,0.006808860000000001,-0.12893370000000004,51.4,1.5897276825145443,9.340002497402642,5.025848172213356e-10,0.266364071401899,996929.829706393,8.651434202976851,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-270G6S6B,Gintung Energy,Mono-c-Si,0,270.0,236.4,1.773277,1.793,0.989,66.0,8.81,40.97,8.3,32.53,0.006422490000000001,-0.14052710000000002,51.4,1.7138639320854614,8.812442030564323,3.646968907762824e-10,0.42029285141570094,1516.2722535420558,6.373839933711573,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-270G6M6A,Gintung Energy,Multi-c-Si,0,270.0,238.3,1.611081,1.629,0.989,60.0,9.28,38.03,8.9,30.34,0.006107167999999999,-0.13032881000000002,50.0,1.6119056637565903,9.280246586934087,5.260170654308726e-10,0.2840197793210061,10688.833650180804,9.28955903767435,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-270G6M6B,Gintung Energy,Multi-c-Si,0,270.0,237.5,1.773277,1.793,0.989,66.0,8.71,41.44,8.25,32.73,0.005732051,-0.14201488,50.0,1.7336603609855372,8.743150247981836,3.6361820950628187e-10,0.4515441287678857,999999.9810600412,6.585871333895374,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-270G6S6A,Gintung Energy,Mono-c-Si,0,270.0,237.2,1.611081,1.629,0.989,60.0,9.34,37.59,8.94,30.2,0.006808860000000001,-0.12893370000000004,51.4,1.5897276825145443,9.340002497402642,5.025848172213356e-10,0.266364071401899,996929.829706393,8.651434202976851,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-270G6S6B,Gintung Energy,Mono-c-Si,0,270.0,236.4,1.773277,1.793,0.989,66.0,8.81,40.97,8.3,32.53,0.006422490000000001,-0.14052710000000002,51.4,1.7138639320854614,8.812442030564323,3.646968907762824e-10,0.42029285141570094,1516.2722535420558,6.373839933711573,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-275G6M,Gintung Energy,Multi-c-Si,0,275.0,245.9,1.956,1.956,1.0,72.0,8.31,44.31,7.87,34.96,0.00177834,-0.14617869000000003,46.1,1.7980453992230667,8.329158410083467,1.6523216002270628e-10,0.5259086088838274,999999.8369848628,4.8524096057984645,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-275G6M6B,Gintung Energy,Multi-c-Si,0,275.0,242.0,1.773277,1.793,0.989,66.0,8.83,41.53,8.38,32.82,0.005811022999999999,-0.14232331,50.0,1.7430114842295406,8.830003713564018,3.964672033503284e-10,0.4202295694910028,999999.9360104373,7.245708626057785,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-275G6S,Gintung Energy,Mono-c-Si,0,275.0,246.4,1.956,1.956,1.0,72.0,8.4,44.36,7.89,34.86,0.0035532,-0.15069092,45.8,1.8325868952537987,8.405220536093486,2.565983338611712e-10,0.5355869372300933,861.7759832108579,5.1757418183141475,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-275G6S6B,Gintung Energy,Mono-c-Si,0,275.0,241.0,1.773277,1.793,0.989,66.0,8.93,41.06,8.42,32.66,0.006509970000000001,-0.1408358,51.4,1.71869226011805,8.931766151067082,3.7545675878894214e-10,0.4072864154092702,2059.321777174801,6.505842387705275,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-275G6M6B,Gintung Energy,Multi-c-Si,0,275.0,242.0,1.773277,1.793,0.989,66.0,8.83,41.53,8.38,32.82,0.005811022999999999,-0.14232331,50.0,1.7430114842295406,8.830003713564018,3.964672033503284e-10,0.4202295694910028,999999.9360104373,7.245708626057785,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-275G6S6B,Gintung Energy,Mono-c-Si,0,275.0,241.0,1.773277,1.793,0.989,66.0,8.93,41.06,8.42,32.66,0.006509970000000001,-0.1408358,51.4,1.71869226011805,8.931766151067082,3.7545675878894214e-10,0.4072864154092702,2059.321777174801,6.505842387705275,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-280G6M,Gintung Energy,Multi-c-Si,0,280.0,250.5,1.956,1.956,1.0,72.0,8.42,44.39,7.99,35.05,0.0018018799999999998,-0.14644261000000003,46.1,1.8055021081931826,8.42000418448483,1.7691468590802829e-10,0.49677748093296337,999999.9393149917,5.335846743157559,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-280G6M6B,Gintung Energy,Multi-c-Si,0,280.0,246.6,1.773277,1.793,0.989,66.0,8.93,41.64,8.49,32.98,0.005876833,-0.14270028,50.0,1.750953817150185,8.930003567232328,4.195191889111661e-10,0.39915322787596424,999999.8017702042,7.639254620768432,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-280G6S,Gintung Energy,Mono-c-Si,0,280.0,251.0,1.956,1.956,1.0,72.0,8.52,44.55,8.01,34.96,0.00360396,-0.15133635,45.8,1.8381033962931037,8.524141477065596,2.5271107462540364e-10,0.5375127182703946,1105.7918164773587,4.922868380177909,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-280G6S6B,Gintung Energy,Mono-c-Si,0,280.0,245.5,1.773277,1.793,0.989,66.0,9.03,41.18,8.53,32.83,0.00658287,-0.14124740000000002,51.4,1.7246491129232495,9.030289248767401,3.852581036526904e-10,0.39349324377461653,12284.499716969514,6.627492726874033,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-280G6M,Gintung Energy,Multi-c-Si,0,280.0,250.5,1.956,1.956,1.0,72.0,8.42,44.39,7.99,35.05,0.0018018799999999998,-0.14644261000000003,46.1,1.8055021081931826,8.42000418448483,1.7691468590802829e-10,0.49677748093296337,999999.9393149917,5.335846743157559,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-280G6M6B,Gintung Energy,Multi-c-Si,0,280.0,246.6,1.773277,1.793,0.989,66.0,8.93,41.64,8.49,32.98,0.005876833,-0.14270028,50.0,1.750953817150185,8.930003567232328,4.195191889111661e-10,0.39915322787596424,999999.8017702042,7.639254620768432,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-280G6S,Gintung Energy,Mono-c-Si,0,280.0,251.0,1.956,1.956,1.0,72.0,8.52,44.55,8.01,34.96,0.00360396,-0.15133635,45.8,1.8381033962931037,8.524141477065596,2.5271107462540364e-10,0.5375127182703946,1105.7918164773587,4.922868380177909,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-280G6S6B,Gintung Energy,Mono-c-Si,0,280.0,245.5,1.773277,1.793,0.989,66.0,9.03,41.18,8.53,32.83,0.00658287,-0.14124740000000002,51.4,1.7246491129232495,9.030289248767401,3.852581036526904e-10,0.39349324377461653,12284.499716969514,6.627492726874033,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-285G6M,Gintung Energy,Multi-c-Si,0,285.0,255.1,1.956,1.956,1.0,72.0,8.51,44.53,8.12,35.1,0.0018211399999999997,-0.14690447,46.1,1.8142554845339647,8.510004022627099,1.8637389571769086e-10,0.4725083522606094,999985.680115981,5.6864121126257,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-285G6M6B,Gintung Energy,Multi-c-Si,0,285.0,251.1,1.773277,1.793,0.989,66.0,9.03,41.75,8.61,33.1,0.005942642999999999,-0.14307725,50.0,1.7588461208405664,9.030003414998191,4.433750114668366e-10,0.3778904207060129,999998.4293896866,8.02483414350318,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-285G6S,Gintung Energy,Mono-c-Si,0,285.0,255.6,1.956,1.956,1.0,72.0,8.64,44.69,8.13,35.06,0.0036547199999999998,-0.15181192999999998,45.8,1.8427636826984577,8.643133544233965,2.5281161892612307e-10,0.5330503466484444,1469.7603663119203,4.80489435341075,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-285G6S6B,Gintung Energy,Mono-c-Si,0,285.0,250.0,1.773277,1.793,0.989,66.0,9.13,41.29,8.65,32.95,0.006655770000000001,-0.14162470000000002,51.4,1.7294783037090349,9.15508100154759,3.9192642231504774e-10,0.38485403580943744,999999.9812815938,6.658298380196374,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-285G6M,Gintung Energy,Multi-c-Si,0,285.0,255.1,1.956,1.956,1.0,72.0,8.51,44.53,8.12,35.1,0.0018211399999999997,-0.14690447,46.1,1.8142554845339647,8.510004022627099,1.8637389571769086e-10,0.4725083522606094,999985.680115981,5.6864121126257,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-285G6M6B,Gintung Energy,Multi-c-Si,0,285.0,251.1,1.773277,1.793,0.989,66.0,9.03,41.75,8.61,33.1,0.005942642999999999,-0.14307725,50.0,1.7588461208405664,9.030003414998191,4.433750114668366e-10,0.3778904207060129,999998.4293896866,8.02483414350318,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-285G6S,Gintung Energy,Mono-c-Si,0,285.0,255.6,1.956,1.956,1.0,72.0,8.64,44.69,8.13,35.06,0.0036547199999999998,-0.15181192999999998,45.8,1.8427636826984577,8.643133544233965,2.5281161892612307e-10,0.5330503466484444,1469.7603663119203,4.80489435341075,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-285G6S6B,Gintung Energy,Mono-c-Si,0,285.0,250.0,1.773277,1.793,0.989,66.0,9.13,41.29,8.65,32.95,0.006655770000000001,-0.14162470000000002,51.4,1.7294783037090349,9.15508100154759,3.9192642231504774e-10,0.38485403580943744,999999.9812815938,6.658298380196374,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-290G6M,Gintung Energy,Multi-c-Si,0,290.0,259.7,1.956,1.956,1.0,72.0,8.62,44.61,8.24,35.2,0.0018446799999999998,-0.14716839,46.1,1.8198738015421632,8.620004184957411,1.9488554123365336e-10,0.452522511764269,931597.889956603,5.956258091258591,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-290G6M6B,Gintung Energy,Multi-c-Si,0,290.0,255.7,1.773277,1.793,0.989,66.0,9.12,41.89,8.74,33.18,0.006001871999999998,-0.14355703,50.0,1.7688324889273999,9.120290602523653,4.728692836504482e-10,0.35185919203421817,11042.514505123834,8.503576319070175,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-290G6S,Gintung Energy,Mono-c-Si,0,290.0,260.2,1.956,1.956,1.0,72.0,8.75,44.84,8.25,35.16,0.00370125,-0.15232148,45.8,1.8465674649733492,8.75072004514435,2.48755107414041e-10,0.5304202705037976,6445.688101459703,4.554640754245612,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy ASEC-290G6S6B,Gintung Energy,Mono-c-Si,0,290.0,254.6,1.773277,1.793,0.989,66.0,9.22,41.44,8.78,33.03,0.006721380000000001,-0.14213920000000002,51.4,1.7415925425670717,9.220003269618937,4.275528510941055e-10,0.35436597820931487,999999.6338758497,7.349066323584713,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-290G6M,Gintung Energy,Multi-c-Si,0,290.0,259.7,1.956,1.956,1.0,72.0,8.62,44.61,8.24,35.2,0.0018446799999999998,-0.14716839,46.1,1.8198738015421632,8.620004184957411,1.9488554123365336e-10,0.452522511764269,931597.889956603,5.956258091258591,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-290G6M6B,Gintung Energy,Multi-c-Si,0,290.0,255.7,1.773277,1.793,0.989,66.0,9.12,41.89,8.74,33.18,0.006001871999999998,-0.14355703,50.0,1.7688324889273999,9.120290602523653,4.728692836504482e-10,0.35185919203421817,11042.514505123834,8.503576319070175,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-290G6S,Gintung Energy,Mono-c-Si,0,290.0,260.2,1.956,1.956,1.0,72.0,8.75,44.84,8.25,35.16,0.00370125,-0.15232148,45.8,1.8465674649733492,8.75072004514435,2.48755107414041e-10,0.5304202705037976,6445.688101459703,4.554640754245612,-0.4684,N,2025.7.3,6/23/2025,4.0,first_pass +Gintung Energy GTEC-290G6S6B,Gintung Energy,Mono-c-Si,0,290.0,254.6,1.773277,1.793,0.989,66.0,9.22,41.44,8.78,33.03,0.006721380000000001,-0.14213920000000002,51.4,1.7415925425670717,9.220003269618937,4.275528510941055e-10,0.35436597820931487,999999.6338758497,7.349066323584713,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-295G6M,Gintung Energy,Multi-c-Si,0,295.0,259.4,1.956,1.956,1.0,72.0,8.72,44.69,8.34,35.37,0.0057386320000000005,-0.15315262999999998,50.0,1.8845885323644174,8.720311405224594,4.382668740207298e-10,0.4077483880073473,11417.900535656587,8.230406636718799,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-295G6M6B,Gintung Energy,Multi-c-Si,0,295.0,260.2,1.773277,1.793,0.989,66.0,9.22,41.99,8.85,33.33,0.006067682,-0.14389973000000003,50.0,1.7762263381615817,9.220276492274444,4.987020961803777e-10,0.3315842269155034,11057.205246189287,8.875776627818633,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-295G6S,Gintung Energy,Mono-c-Si,0,295.0,258.2,1.956,1.956,1.0,72.0,8.83,44.96,8.35,35.33,0.0064370700000000005,-0.1542128,51.4,1.8680260231452972,8.852224213479396,3.121542942616128e-10,0.5113521670329099,999999.9831769019,4.995913664315172,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-295G6S6B,Gintung Energy,Mono-c-Si,0,295.0,259.1,1.773277,1.793,0.989,66.0,9.32,41.54,8.89,33.18,0.006794280000000001,-0.1424822,51.4,1.7489646555649707,9.320003126201001,4.512335054833719e-10,0.3351884679092873,999998.932418691,7.724887406478567,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-295G6M,Gintung Energy,Multi-c-Si,0,295.0,259.4,1.956,1.956,1.0,72.0,8.72,44.69,8.34,35.37,0.0057386320000000005,-0.15315262999999998,50.0,1.8845885323644174,8.720311405224594,4.382668740207298e-10,0.4077483880073473,11417.900535656587,8.230406636718799,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-295G6M6B,Gintung Energy,Multi-c-Si,0,295.0,260.2,1.773277,1.793,0.989,66.0,9.22,41.99,8.85,33.33,0.006067682,-0.14389973000000003,50.0,1.7762263381615817,9.220276492274444,4.987020961803777e-10,0.3315842269155034,11057.205246189287,8.875776627818633,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-295G6S,Gintung Energy,Mono-c-Si,0,295.0,258.2,1.956,1.956,1.0,72.0,8.83,44.96,8.35,35.33,0.0064370700000000005,-0.1542128,51.4,1.8680260231452972,8.852224213479396,3.121542942616128e-10,0.5113521670329099,999999.9831769019,4.995913664315172,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-295G6S6B,Gintung Energy,Mono-c-Si,0,295.0,259.1,1.773277,1.793,0.989,66.0,9.32,41.54,8.89,33.18,0.006794280000000001,-0.1424822,51.4,1.7489646555649707,9.320003126201001,4.512335054833719e-10,0.3351884679092873,999998.932418691,7.724887406478567,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-300G6M,Gintung Energy,Multi-c-Si,0,300.0,263.9,1.956,1.956,1.0,72.0,8.83,44.78,8.45,35.5,0.005811022999999999,-0.15346106,50.0,1.8903867983777638,8.830304313576448,4.5508841739964687e-10,0.39273578824872935,11395.759159736157,8.450838292660075,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-300G6S,Gintung Energy,Mono-c-Si,0,300.0,262.8,1.956,1.956,1.0,72.0,8.91,45.07,8.46,35.46,0.00649539,-0.1545901,51.4,1.8798510395784485,8.910004212734984,3.4477321427317717e-10,0.4724851169609153,999999.95217153,5.786469868065204,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-300G6M,Gintung Energy,Multi-c-Si,0,300.0,263.9,1.956,1.956,1.0,72.0,8.83,44.78,8.45,35.5,0.005811022999999999,-0.15346106,50.0,1.8903867983777638,8.830304313576448,4.5508841739964687e-10,0.39273578824872935,11395.759159736157,8.450838292660075,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-300G6S,Gintung Energy,Mono-c-Si,0,300.0,262.8,1.956,1.956,1.0,72.0,8.91,45.07,8.46,35.46,0.00649539,-0.1545901,51.4,1.8798510395784485,8.910004212734984,3.4477321427317717e-10,0.4724851169609153,999999.95217153,5.786469868065204,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-305G6M,Gintung Energy,Multi-c-Si,0,305.0,268.5,1.956,1.956,1.0,72.0,8.95,44.88,8.57,35.59,0.005889994999999999,-0.15380376,50.0,1.8954268088728103,8.950302155500028,4.660172359104434e-10,0.38355234677469313,11361.105530908384,8.540730364484704,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-305G6S,Gintung Energy,Mono-c-Si,0,305.0,267.3,1.956,1.956,1.0,72.0,8.99,45.18,8.58,35.55,0.006553710000000001,-0.1549674,51.4,1.8891894331904027,8.990003980763383,3.6948532027957233e-10,0.4424912315295574,999974.2962285853,6.304300367171614,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-305G6M,Gintung Energy,Multi-c-Si,0,305.0,268.5,1.956,1.956,1.0,72.0,8.95,44.88,8.57,35.59,0.005889994999999999,-0.15380376,50.0,1.8954268088728103,8.950302155500028,4.660172359104434e-10,0.38355234677469313,11361.105530908384,8.540730364484704,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-305G6S,Gintung Energy,Mono-c-Si,0,305.0,267.3,1.956,1.956,1.0,72.0,8.99,45.18,8.58,35.55,0.006553710000000001,-0.1549674,51.4,1.8891894331904027,8.990003980763383,3.6948532027957233e-10,0.4424912315295574,999974.2962285853,6.304300367171614,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-310G6M,Gintung Energy,Multi-c-Si,0,310.0,273.0,1.956,1.956,1.0,72.0,9.05,44.97,8.67,35.76,0.005955805,-0.15411219,50.0,1.9021751957653112,9.050290414103687,4.888352488709226e-10,0.36499071257117544,11374.075335873027,8.863735945355932,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-310G6S,Gintung Energy,Mono-c-Si,0,310.0,271.8,1.956,1.956,1.0,72.0,9.08,45.22,8.68,35.71,0.006619320000000001,-0.1551046,51.4,1.8955963002558545,9.080004083679713,3.9615282750144416e-10,0.4137192432877387,919552.0748845307,6.819944744705995,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-310G6M,Gintung Energy,Multi-c-Si,0,310.0,273.0,1.956,1.956,1.0,72.0,9.05,44.97,8.67,35.76,0.005955805,-0.15411219,50.0,1.9021751957653112,9.050290414103687,4.888352488709226e-10,0.36499071257117544,11374.075335873027,8.863735945355932,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-310G6S,Gintung Energy,Mono-c-Si,0,310.0,271.8,1.956,1.956,1.0,72.0,9.08,45.22,8.68,35.71,0.006619320000000001,-0.1551046,51.4,1.8955963002558545,9.080004083679713,3.9615282750144416e-10,0.4137192432877387,919552.0748845307,6.819944744705995,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-315G6M,Gintung Energy,Multi-c-Si,0,315.0,277.6,1.956,1.956,1.0,72.0,9.15,45.09,8.78,35.88,0.006021615,-0.15452343000000002,50.0,1.9091956940990877,9.15020775098506,5.063372411914607e-10,0.35009729150274516,15419.53781792434,9.07690796467552,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-315G6S,Gintung Energy,Mono-c-Si,0,315.0,276.4,1.956,1.956,1.0,72.0,9.18,45.27,8.79,35.84,0.0066922200000000005,-0.15527610000000003,51.4,1.9021292938343772,9.180314655660819,4.232666962452355e-10,0.38761961090358105,11308.788284100952,7.30038014935621,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-315G6M,Gintung Energy,Multi-c-Si,0,315.0,277.6,1.956,1.956,1.0,72.0,9.15,45.09,8.78,35.88,0.006021615,-0.15452343000000002,50.0,1.9091956940990877,9.15020775098506,5.063372411914607e-10,0.35009729150274516,15419.53781792434,9.07690796467552,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-315G6S,Gintung Energy,Mono-c-Si,0,315.0,276.4,1.956,1.956,1.0,72.0,9.18,45.27,8.79,35.84,0.0066922200000000005,-0.15527610000000003,51.4,1.9021292938343772,9.180314655660819,4.232666962452355e-10,0.38761961090358105,11308.788284100952,7.30038014935621,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-320G6M,Gintung Energy,Multi-c-Si,0,320.0,282.1,1.956,1.956,1.0,72.0,9.27,45.18,8.9,35.96,0.0061005869999999985,-0.15483186,50.0,1.9138926632866193,9.270279141616891,5.185649595259854e-10,0.34153212141186184,11342.012037783055,9.172973479392525,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-320G6S,Gintung Energy,Mono-c-Si,0,320.0,280.9,1.956,1.956,1.0,72.0,9.28,45.31,8.91,35.91,0.00676512,-0.15541330000000003,51.4,1.9073133292792126,9.280297856163013,4.4699820611885724e-10,0.36350472075015955,11325.427433967096,7.681244353250221,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-320G6M,Gintung Energy,Multi-c-Si,0,320.0,282.1,1.956,1.956,1.0,72.0,9.27,45.18,8.9,35.96,0.0061005869999999985,-0.15483186,50.0,1.9138926632866193,9.270279141616891,5.185649595259854e-10,0.34153212141186184,11342.012037783055,9.172973479392525,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-320G6S,Gintung Energy,Mono-c-Si,0,320.0,280.9,1.956,1.956,1.0,72.0,9.28,45.31,8.91,35.91,0.00676512,-0.15541330000000003,51.4,1.9073133292792126,9.280297856163013,4.4699820611885724e-10,0.36350472075015955,11325.427433967096,7.681244353250221,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-325G6M,Gintung Energy,Multi-c-Si,0,325.0,286.7,1.956,1.956,1.0,72.0,9.38,45.35,9.01,36.07,0.006172978,-0.15541445,50.0,1.9209022220252594,9.380281060472567,5.234835674501495e-10,0.3389836961749439,11313.195553030944,9.152133254548373,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy ASEC-325G6S,Gintung Energy,Mono-c-Si,0,325.0,285.5,1.956,1.956,1.0,72.0,9.39,45.48,9.03,35.99,0.006845310000000001,-0.1559964,51.4,1.9145775976432142,9.390296687730622,4.5290533573503977e-10,0.3576779117676149,11320.387346720268,7.692975868205688,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-325G6M,Gintung Energy,Multi-c-Si,0,325.0,286.7,1.956,1.956,1.0,72.0,9.38,45.35,9.01,36.07,0.006172978,-0.15541445,50.0,1.9209022220252594,9.380281060472567,5.234835674501495e-10,0.3389836961749439,11313.195553030944,9.152133254548373,-0.4607,N,2025.7.3,6/23/2025,2.0,first_pass +Gintung Energy GTEC-325G6S,Gintung Energy,Mono-c-Si,0,325.0,285.5,1.956,1.956,1.0,72.0,9.39,45.48,9.03,35.99,0.006845310000000001,-0.1559964,51.4,1.9145775976432142,9.390296687730622,4.5290533573503977e-10,0.3576779117676149,11320.387346720268,7.692975868205688,-0.4502,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP395-54-182PMBB,Global Power Services LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,37.0,12.81,30.8,0.007397999999999999,-0.10064000000000001,43.6,1.401112053396488,13.718401636004915,4.5467711736231086e-11,0.14579716737264542,108.54584935188754,9.914154993638125,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP395-54-182PMWB,Global Power Services LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,37.0,12.81,30.8,0.007397999999999999,-0.10064000000000001,43.6,1.401112053396488,13.718401636004915,4.5467711736231086e-11,0.14579716737264542,108.54584935188754,9.914154993638125,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP400-54-182PMBB,Global Power Services LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.0,12.9,31.0,0.007446599999999999,-0.10064000000000001,43.6,1.405525586039239,13.806185608837279,4.971883658960144e-11,0.12698888506058306,108.19344250773712,10.654167514200976,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP400-54-182PMWB,Global Power Services LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.0,12.9,31.0,0.007446599999999999,-0.10064000000000001,43.6,1.405525586039239,13.806185608837279,4.971883658960144e-11,0.12698888506058306,108.19344250773712,10.654167514200976,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP405-54-182PMBB,Global Power Services LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.2,12.98,31.2,0.0074898,-0.10118400000000002,43.6,1.4136049317724912,13.885653601947263,5.047677708958482e-11,0.12409551906465267,109.95583438500063,10.736597514315712,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP405-54-182PMWB,Global Power Services LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.2,12.98,31.2,0.0074898,-0.10118400000000002,43.6,1.4136049317724912,13.885653601947263,5.047677708958482e-11,0.12409551906465267,109.95583438500063,10.736597514315712,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP410-54-182PMBB,Global Power Services LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.3,13.04,31.5,0.007532999999999999,-0.101456,43.6,1.4233184991192205,13.964301567322108,5.652072432988775e-11,0.104494465020068,101.92573757276448,11.710011806016594,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP410-54-182PMWB,Global Power Services LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.3,13.04,31.5,0.007532999999999999,-0.101456,43.6,1.4233184991192205,13.964301567322108,5.652072432988775e-11,0.104494465020068,101.92573757276448,11.710011806016594,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP415-54-182PMBB,Global Power Services LLC,Mono-c-Si,0,415.0,389.4,1.95,,,54.0,14.02,37.45,13.13,31.61,0.00758482,-0.10186400000000002,43.6,1.4268018200180161,14.0333563973722,5.463672240262274e-11,0.10616428128059485,111.43897514456997,11.34958194532629,-0.3526,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP415-54-182PMWB,Global Power Services LLC,Mono-c-Si,0,415.0,389.4,1.95,,,54.0,14.02,37.45,13.13,31.61,0.00758482,-0.10186400000000002,43.6,1.4268018200180161,14.0333563973722,5.463672240262274e-11,0.10616428128059485,111.43897514456997,11.34958194532629,-0.3526,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP435-60-182PMBB,Global Power Services LLC,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,41.0,12.96,33.6,0.007381800000000001,-0.11152000000000002,43.6,1.529753992196075,13.676110956682624,3.114263089377789e-11,0.21010601205766605,469.99993863841866,6.551713688813641,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP435-60-182PMWB,Global Power Services LLC,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,41.0,12.96,33.6,0.007381800000000001,-0.11152000000000002,43.6,1.529753992196075,13.676110956682624,3.114263089377789e-11,0.21010601205766605,469.99993863841866,6.551713688813641,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP440-60-182PMBB,Global Power Services LLC,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.0,13.05,33.7,0.0074142,-0.11152000000000002,43.6,1.5302380974126233,13.733227689903009,3.1630274073642386e-11,0.20038228792807086,852.3894912001904,6.638704358612484,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP440-60-182PMWB,Global Power Services LLC,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.0,13.05,33.7,0.0074142,-0.11152000000000002,43.6,1.5302380974126233,13.733227689903009,3.1630274073642386e-11,0.20038228792807086,852.3894912001904,6.638704358612484,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP445-60-182PMBB,Global Power Services LLC,Mono-c-Si,0,445.0,417.1,2.16,,,60.0,13.79,41.1,13.16,33.8,0.007446599999999999,-0.11179200000000002,43.6,1.5331244854823864,13.790002691854419,3.140486476311248e-11,0.19519241000659182,999999.8780740772,6.527530390213811,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP445-60-182PMWB,Global Power Services LLC,Mono-c-Si,0,445.0,417.1,2.16,,,60.0,13.79,41.1,13.16,33.8,0.007446599999999999,-0.11179200000000002,43.6,1.5331244854823864,13.790002691854419,3.140486476311248e-11,0.19519241000659182,999999.8780740772,6.527530390213811,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP450-60-182PMBB,Global Power Services LLC,Mono-c-Si,0,450.0,421.9,2.16,,,60.0,13.85,41.2,13.27,33.9,0.007479,-0.11206400000000001,43.6,1.5398499053856847,13.850002519631197,3.3229866633604754e-11,0.1819104539202851,999985.7845830459,6.978858187866988,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP450-60-182PMWB,Global Power Services LLC,Mono-c-Si,0,450.0,421.9,2.16,,,60.0,13.85,41.2,13.27,33.9,0.007479,-0.11206400000000001,43.6,1.5398499053856847,13.850002519631197,3.3229866633604754e-11,0.1819104539202851,999985.7845830459,6.978858187866988,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP455-60-182PMBB,Global Power Services LLC,Mono-c-Si,0,455.0,426.7,2.16,,,60.0,13.93,41.3,13.36,34.1,0.007522200000000001,-0.112336,43.6,1.5465595465608057,13.930002353280006,3.518526499040645e-11,0.16892624032954812,999995.1003490807,7.425641680065245,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP455-60-182PMWB,Global Power Services LLC,Mono-c-Si,0,455.0,426.7,2.16,,,60.0,13.93,41.3,13.36,34.1,0.007522200000000001,-0.112336,43.6,1.5465595465608057,13.930002353280006,3.518526499040645e-11,0.16892624032954812,999995.1003490807,7.425641680065245,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP460-60-182PMBB,Global Power Services LLC,Mono-c-Si,0,460.0,431.6,2.16,,,60.0,14.01,41.48,13.45,34.2,0.007579410000000001,-0.11282560000000001,43.6,1.5524721762199485,14.010002376709336,3.4887003869949945e-11,0.16963465526314545,999999.4221514936,7.30043531295308,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP460-60-182PMWB,Global Power Services LLC,Mono-c-Si,0,460.0,431.6,2.16,,,60.0,14.01,41.48,13.45,34.2,0.007579410000000001,-0.11282560000000001,43.6,1.5524721762199485,14.010002376709336,3.4887003869949945e-11,0.16963465526314545,999999.4221514936,7.30043531295308,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP530-72-182PMTW,Global Power Services LLC,Mono-c-Si,0,530.0,499.1,2.58,,,72.0,13.71,49.2,12.82,41.4,0.005484,-0.140712,43.1,1.8177168054163746,13.726885700899235,2.347840466886919e-11,0.16348162284110615,132.73556544102203,-0.7620307730197329,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP535-72-182PMTW,Global Power Services LLC,Mono-c-Si,0,535.0,503.9,2.58,,,72.0,13.78,49.4,12.9,41.5,0.005512,-0.141284,43.1,1.822514816026605,13.796665255905195,2.2741037749837433e-11,0.1695403063963445,140.1877921182044,-1.0642107024438168,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP535-72G-182BPM,Global Power Services LLC,Mono-c-Si,0,535.0,504.0,2.57,,,72.0,13.78,49.35,12.9,41.5,0.00500214,-0.13669950000000003,43.2,1.807552380510051,13.796819228054702,1.8672056475802498e-11,0.16808111709335782,137.7089242373536,0.6012352993183838,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP540-72-182PMTW,Global Power Services LLC,Mono-c-Si,0,540.0,508.8,2.58,,,72.0,13.85,49.5,12.97,41.7,0.005540000000000001,-0.14156999999999997,43.1,1.8285216186657303,13.865594529876685,2.3658970186262416e-11,0.15879487076002038,141.0307965004113,-0.7876494396720093,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP540-72G-182BPM,Global Power Services LLC,Mono-c-Si,0,540.0,508.8,2.57,,,72.0,13.85,49.5,12.97,41.65,0.00502755,-0.13711500000000001,43.2,1.8132661183789467,13.866454243113246,1.8835726824329694e-11,0.16567111667133436,139.45004682289462,0.6298632449013583,-0.3353,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP545-72-182PMTW,Global Power Services LLC,Mono-c-Si,0,545.0,513.6,2.58,,,72.0,13.92,49.7,13.04,41.8,0.005568,-0.142142,43.1,1.8340400207104455,13.935940720497232,2.314408745731457e-11,0.16471144347818584,143.83184898116463,-1.0067463365185205,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP545-72G-182BPM,Global Power Services LLC,Mono-c-Si,0,545.0,513.6,2.57,,,72.0,13.92,49.65,13.04,41.8,0.00505296,-0.1375305,43.2,1.8189806959533932,13.936094916667075,1.9000118668155362e-11,0.1632868812527612,141.22181798244748,0.6584113642523622,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP550-72-182PMTW,Global Power Services LLC,Mono-c-Si,0,550.0,518.4,2.58,,,72.0,13.99,49.8,13.11,42.0,0.005596,-0.142428,43.1,1.8400454932892913,14.004900476948619,2.4070751679311814e-11,0.15410834765845804,144.69173037021588,-0.7321354881926299,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP550-72G-182BPM,Global Power Services LLC,Mono-c-Si,0,550.0,518.5,2.57,,,72.0,13.99,49.8,13.11,41.95,0.00507837,-0.137946,43.2,1.8246961440467402,14.00574119889923,1.9165241597205742e-11,0.16092799286718248,143.02485054801647,0.6868853510655905,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +Global Power Services LLC GP555-72-182PMTW,Global Power Services LLC,Mono-c-Si,0,555.0,523.3,2.58,,,72.0,14.02,50.0,13.18,42.1,0.005608,-0.143,43.1,1.842935298986658,14.033061991031586,2.266780253735756e-11,0.16080489272716508,172.598848032139,-1.2445382027776486,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Global Power Services LLC GP555-72G-182BPM,Global Power Services LLC,Mono-c-Si,0,555.0,523.3,2.57,,,72.0,14.02,49.95,13.18,42.09,0.00508926,-0.13836150000000003,43.2,1.8276061971576338,14.033297479756067,1.854744956353901e-11,0.1602745922036483,168.98313319433055,0.3889870935193644,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +Goldi Solar Private Limited GOLDI060F260PY24,Goldi Solar Private Limited,Multi-c-Si,0,260.0,238.9,1.5714,,,60.0,8.9,38.12,8.57,30.4,0.0008099000000000001,-0.09972191999999999,46.43,1.3696190947684528,8.900003615389931,7.275497974202254e-12,0.3742551223947979,921322.2518615762,2.545745301883854,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F265PY24,Goldi Solar Private Limited,Multi-c-Si,0,265.0,243.6,1.5714,,,60.0,8.97,38.32,8.64,30.700000000000003,0.00081627,-0.10024512,46.43,1.3795398966065955,8.970003445685093,7.748702408198452e-12,0.3546146143671476,923171.0453460701,3.0047205182218546,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F270PY24,Goldi Solar Private Limited,Multi-c-Si,0,270.0,248.3,1.5714,,,60.0,9.030000000000001,38.519999999999996,8.72,31.000000000000004,0.0008217300000000002,-0.10076832,46.43,1.3906868624093767,9.030003159638722,8.440369875915984e-12,0.32463629656950527,927802.7059565467,3.6636366135076845,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F275PY24,Goldi Solar Private Limited,Multi-c-Si,0,275.0,253.0,1.5714,,,60.0,9.100000000000001,38.82,8.8,31.300000000000008,0.0008281000000000001,-0.10155312,46.43,1.4033646498093653,9.100003036375032,8.821577756301324e-12,0.3103661330502791,930182.8397735328,3.9695883448441864,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F280PY24,Goldi Solar Private Limited,Multi-c-Si,0,280.0,257.7,1.5714,,,60.0,9.180000000000001,39.12,8.88,31.60000000000001,0.0008353800000000003,-0.10233792,46.43,1.4154462280501197,9.180002973110751,9.116780523006118e-12,0.3015320775215355,931050.0545700417,4.17283900987905,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F285PY24,Goldi Solar Private Limited,Multi-c-Si,0,285.0,262.4,1.5714,,,60.0,9.25,39.42,8.95,31.85,0.00084175,-0.10312272000000001,46.43,1.4265837512993813,9.250002972282068,9.236780007532401e-12,0.2992920824578041,931439.864301915,4.2189862107790965,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F290PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,290.0,269.0,1.5714,,,60.0,9.36,39.65,9.04,32.1,9.36e-05,-0.09369295000000001,46.82,1.3550700798444442,9.360003286517284,1.8348870975606387e-12,0.32912696870875385,937357.6290849936,1.1741487217486541,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F295PRC24,Goldi Solar Private Limited,Mono-c-Si,0,295.0,273.4,1.5714,,,60.0,9.45,39.85,9.12,32.35,0.00014175,-0.09663625,46.31,1.3904662407285233,9.451375616968177,3.3736336837282464e-12,0.3531832632087675,2426.2436394757838,3.542353158978476,-0.3474,N,2025.7.3,6/23/2025,4.0,first_pass +Goldi Solar Private Limited GOLDI060F295PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,295.0,273.7,1.5714,,,60.0,9.45,39.85,9.12,32.35,9.45e-05,-0.09416555000000001,46.82,1.36295626290895,9.45000323850752,1.894805566196829e-12,0.32100713194106806,936706.4041254472,1.3617943456823478,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F300PRC24,Goldi Solar Private Limited,Mono-c-Si,0,300.0,278.2,1.5714,,,60.0,9.53,40.1,9.19,32.65,0.00014295,-0.09724250000000001,46.31,1.3973666279917825,9.530003099423476,3.2825689638566295e-12,0.30381765713190645,934174.4981122101,3.233638931515617,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F300PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,300.0,278.5,1.5714,,,60.0,9.53,40.1,9.19,32.65,9.53e-05,-0.09475630000000002,46.82,1.3726838423596572,9.530003167645079,1.959358113290818e-12,0.31277058499088756,940988.1759929826,1.5706278181463988,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F305PRC24,Goldi Solar Private Limited,Mono-c-Si,0,305.0,283.0,1.5714,,,60.0,9.62,40.4,9.28,32.87,0.00014429999999999998,-0.09796999999999999,46.31,1.407594063137822,9.620003135927139,3.2982912985906345e-12,0.3043923310140915,933782.7338056595,3.1947384629982176,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F305PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,305.0,283.2,1.5714,,,60.0,9.62,40.4,9.28,32.87,9.62e-05,-0.0954652,46.82,1.3827361240858709,9.62000320480869,1.9688080170782206e-12,0.31334652724600015,940588.6509558964,1.5323824499558851,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F310PRC24,Goldi Solar Private Limited,Mono-c-Si,0,310.0,287.7,1.5714,,,60.0,9.71,40.6,9.38,33.05,0.00014565000000000002,-0.098455,46.31,1.4155943836525098,9.710003059812712,3.399543818373087e-12,0.2945171488126739,934626.1943549621,3.3709735829026592,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F310PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,310.0,288.0,1.5714,,,60.0,9.71,40.6,9.38,33.05,9.71e-05,-0.09593780000000002,46.82,1.3905740856772388,9.710003132145207,2.0291128883906026e-12,0.30353822101087796,941006.4033455104,1.7063468794397862,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F315PRC24,Goldi Solar Private Limited,Mono-c-Si,0,315.0,292.5,1.5714,,,60.0,9.82,40.85,9.45,33.35,0.00014730000000000003,-0.09906125,46.31,1.4238895677527508,9.820003161656004,3.408988026714404e-12,0.29961901029833,930613.4034524838,3.2994315825172724,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F315PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,315.0,292.8,1.5714,,,60.0,9.82,40.85,9.45,33.35,9.820000000000002e-05,-0.09652855,46.82,1.3987267921067132,9.82000323423997,2.0346148710590268e-12,0.30834955260164976,936234.1766712536,1.6349492276445536,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F320PRC24,Goldi Solar Private Limited,Mono-c-Si,0,320.0,297.3,1.5714,,,60.0,9.9,41.15,9.53,33.6,0.0001485,-0.09978875,46.31,1.4346040102313613,9.90000316339214,3.4545016003566057e-12,0.2974426692857049,930868.8310943978,3.342812672349919,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F320PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,320.0,300.1,1.57,,,60.0,9.9,41.15,9.53,33.6,0.0027423,-0.0984308,44.9,1.436745706571102,9.900003155845784,3.6054119429007862e-12,0.2967040006811713,930777.7597187547,4.76452219309818,-0.3253,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F320PY24,Goldi Solar Private Limited,Multi-c-Si,0,320.0,294.2,1.87889,,,72.0,9.05,45.7,8.68,36.9,0.0008235500000000001,-0.11955120000000001,46.43,1.647713345112323,9.050003836698306,8.152904013786955e-12,0.40692049225528565,959859.9691135691,3.3550501593193705,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F325PRC24,Goldi Solar Private Limited,Mono-c-Si,0,325.0,302.0,1.5714,,,60.0,9.98,41.35,9.63,33.75,0.0001497,-0.10027375000000001,46.31,1.4426514519045395,9.980003074151512,3.557642679280974e-12,0.28726794887121126,932600.0612574569,3.523035803070529,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI060F325PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,325.0,304.9,1.57,,,60.0,9.98,41.35,9.63,33.75,0.00276446,-0.0989092,44.9,1.4448678342085606,9.980002859290822,3.717553618643318e-12,0.2864978120872968,999993.1897472783,4.958622383642926,-0.3253,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F325PY24,Goldi Solar Private Limited,Multi-c-Si,0,325.0,298.9,1.87889,,,72.0,9.12,45.9,8.75,37.2,0.0008299199999999999,-0.1200744,46.43,1.6576692228176453,9.120003672293068,8.602091382220028e-12,0.38713899503976784,961460.9277178749,3.739620625439909,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F330PY24,Goldi Solar Private Limited,Multi-c-Si,0,330.0,303.6,1.87889,,,72.0,9.19,46.2,8.83,37.4,0.00083629,-0.1208592,46.43,1.6686848141177997,9.190003670369874,8.694211498405568e-12,0.38433502882991827,962327.3520645319,3.7648361473271197,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F335PY24,Goldi Solar Private Limited,Multi-c-Si,0,335.0,308.3,1.87889,,,72.0,9.26,46.5,8.9,37.7,0.0008426600000000001,-0.121644,46.43,1.680772881171354,9.260003609767868,8.943048582059137e-12,0.37547857777458765,963216.6440473434,3.9380469081210157,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F340PY24,Goldi Solar Private Limited,Multi-c-Si,0,340.0,313.1,1.87889,,,72.0,9.32,46.8,8.98,37.9,0.0008481200000000001,-0.12242879999999999,46.43,1.6924949169504433,9.320003542946825,9.131158972901208e-12,0.36703893955537165,965540.2932211136,4.058740547336818,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F345PY24,Goldi Solar Private Limited,Multi-c-Si,0,345.0,317.8,1.87889,,,72.0,9.4,47.1,9.06,38.1,0.0008554000000000001,-0.1232136,46.43,1.7027709952409207,9.40000359958374,9.124203969339696e-12,0.36947349456762235,964863.4969750992,3.980471648761628,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F350PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,350.0,324.7,1.87889,,,72.0,9.48,47.3,9.12,38.4,9.480000000000001e-05,-0.1117699,46.82,1.6159175289903016,9.480003843645825,1.8384170803595763e-12,0.39631923640071015,977488.478403399,1.0842966892327126,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F350PY24,Goldi Solar Private Limited,Multi-c-Si,0,350.0,322.5,1.87889,,,72.0,9.48,47.3,9.12,38.4,0.0008626800000000001,-0.1237368,46.43,1.711270781496074,9.480003563022484,9.392605268653394e-12,0.3621199686876424,963494.5803768107,4.153048903970511,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F355PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,355.0,329.5,1.87889,,,72.0,9.56,47.5,9.2,38.6,9.56e-05,-0.11224250000000001,46.82,1.6235541644647962,9.560003803037471,1.8810005314368223e-12,0.3886747866911827,977046.3440623911,1.2047220326293642,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F360PRC24,Goldi Solar Private Limited,Mono-c-Si,0,360.0,333.9,1.87889,,,72.0,9.64,47.7,9.28,38.8,0.00014460000000000002,-0.11567250000000001,46.31,1.6604846772842172,9.640003688333293,3.223233842850162e-12,0.3707823635125532,969099.7152756971,2.98371017010436,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F360PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,360.0,334.2,1.87889,,,72.0,9.64,47.7,9.28,38.8,9.640000000000001e-05,-0.11567250000000001,46.82,1.6312437074740476,9.640003762351752,1.9260002387217997e-12,0.3811418711849391,976575.437218691,-1.259099634225805,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F365PRC24,Goldi Solar Private Limited,Mono-c-Si,0,365.0,338.6,1.87889,,,72.0,9.72,47.9,9.34,39.1,0.00014580000000000002,-0.1161575,46.31,1.6685983858701723,9.720003645917945,3.3150543497909735e-12,0.3630213637996046,967818.8530292298,3.15037975233075,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F365PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,365.0,339.0,1.87889,,,72.0,9.72,47.9,9.34,39.1,9.72e-05,-0.1161575,46.82,1.6391860848462032,9.720003738616914,1.980565632351017e-12,0.3732302846947275,970361.7684946508,-1.0994907742392204,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F370PRC24,Goldi Solar Private Limited,Mono-c-Si,0,370.0,343.4,1.87889,,,72.0,9.78,48.1,9.42,39.3,0.0001467,-0.11664250000000001,46.31,1.6776961660508745,9.78000348698446,3.4593721567306617e-12,0.3460809631686026,970664.1494687253,3.457505881637541,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F370PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,370.0,343.7,1.87889,,,72.0,9.78,48.1,9.42,39.3,9.78e-05,-0.11664250000000001,46.82,1.648080571022888,9.780003569155696,2.066568716316749e-12,0.3564625669736718,976761.9427771613,-0.8039803114999203,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F375PRC24,Goldi Solar Private Limited,Mono-c-Si,0,375.0,348.2,1.87889,,,72.0,9.84,48.4,9.49,39.52,0.0001476,-0.11736999999999999,46.31,1.6885564510334952,9.840003463521104,3.504105566933525e-12,0.3420778669326045,971862.0943935767,3.5143001793844455,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F375PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,375.0,348.5,1.87889,,,72.0,9.84,48.4,9.49,39.52,9.84e-05,-0.11736999999999999,46.82,1.6587425698497655,9.840003547778439,2.0933028117441217e-12,0.35255961993482665,977850.80754574,-0.7491330468786063,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F380PRC24,Goldi Solar Private Limited,Mono-c-Si,0,380.0,352.9,1.87889,,,72.0,9.92,48.7,9.56,39.75,0.00014879999999999998,-0.11809750000000001,46.31,1.698292251554573,9.920003443500894,3.4893102550382492e-12,0.3470645355386198,999826.4250404257,3.4103109204059074,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F380PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,380.0,353.3,1.87889,,,72.0,9.92,48.7,9.56,39.75,9.92e-05,-0.11809750000000001,46.82,1.6683214307455654,9.920003631645868,2.0845477433204474e-12,0.3574608053765271,976423.1187749739,-0.8491522630988357,-0.3349,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F385PRC24,Goldi Solar Private Limited,Mono-c-Si,0,385.0,357.7,1.87889,,,72.0,9.98,48.9,9.64,39.95,0.0001497,-0.1185825,46.31,1.707360769055211,9.980003383442957,3.6360718846569663e-12,0.3298713566280921,973013.0130165541,3.707199959643346,-0.3474,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F385PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,385.0,361.1,1.88,,,72.0,9.98,48.9,9.64,39.95,0.00276446,-0.1169688,44.9,1.7100293645645044,9.980003374156453,3.802274105702003e-12,0.32893582157826795,972924.1001195085,5.152621386208233,-0.3253,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F390PRC24,Goldi Solar Private Limited,Mono-c-Si,0,390.0,364.1,1.88,,,72.0,10.07,49.15,9.72,40.14,0.00267862,-0.1166821,46.14,1.7239631173254022,10.070003435747013,4.181568684637667e-12,0.331106265549063,970461.8064536287,6.718527638532045,-0.3292,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F390PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,390.0,366.0,1.88,,,72.0,10.07,49.15,9.72,40.14,0.00278939,-0.1175668,44.9,1.7180434727208376,10.070003454991085,3.790331749618008e-12,0.3331522671900774,971019.2050981332,5.048210209434562,-0.3253,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F395PRC24,Goldi Solar Private Limited,Mono-c-Si,0,395.0,368.9,1.88,,,72.0,10.15,49.35,9.8,40.32,0.0026999,-0.11715690000000001,46.14,1.7314582227806687,10.150003415968323,4.2482324569972595e-12,0.3264766398663358,970078.9278229055,6.787573076755589,-0.3292,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F395PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,395.0,370.8,1.88,,,72.0,10.15,49.35,9.8,40.32,0.00281155,-0.11804520000000002,44.9,1.7255128710355203,10.150003435358432,3.8508650346775205e-12,0.3285195531144229,970638.9439312689,5.116506963231662,-0.3253,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F400PRC24,Goldi Solar Private Limited,Mono-c-Si,0,400.0,373.7,1.88,,,72.0,10.21,49.65,9.88,40.48,0.00271586,-0.1178691,46.14,1.7420586099652968,10.210003393836805,4.278578507705615e-12,0.32297479973823345,971641.67600617,6.798268500349206,-0.3292,N,2025.7.3,6/23/2025,2.0,first_pass +Goldi Solar Private Limited GOLDI072F400PRC24B,Goldi Solar Private Limited,Mono-c-Si,0,400.0,375.6,1.88,,,72.0,10.21,49.65,9.88,40.48,0.00282817,-0.1187628,44.9,1.7360820747616912,10.210003413620935,3.878722181241976e-12,0.32505096408916634,972219.5992396318,5.127825854792999,-0.3253,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B108-TF-390,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,390.0,365.9,1.96,,,54.0,13.41,37.0,12.69,30.77,0.02187171,-0.084989,46.83,1.398280645556633,13.41728190706755,4.2800987360667256e-11,0.1514754650526409,278.94973211873463,28.54532893985035,-0.2924,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B108-TF-395,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,395.0,370.7,1.96,,,54.0,13.44,37.05,12.77,30.95,0.021920639999999998,-0.08510385,46.83,1.4005927925580235,13.443613262372367,4.3427827796594296e-11,0.1391211066960875,517.479093461563,28.662543708020802,-0.2924,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B108-TF-400,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,400.0,375.5,1.96,,,54.0,13.47,37.1,12.87,31.1,0.02196957,-0.0852187,46.83,1.3197451081961522,13.471258637916494,8.316984980405622e-12,0.1438267047889463,1539.2399441346329,12.057439284031396,-0.2924,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B108-TF-405,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,405.0,380.3,1.96,,,54.0,13.5,37.15,12.96,31.27,0.0220185,-0.08533355,46.83,1.303692187969557,13.50000335103598,5.684343693532467e-12,0.13579247182488122,547057.0770357221,8.496471102341227,-0.2924,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B144-GF-525,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,525.0,490.5,2.58,,,72.0,13.36,49.25,12.12,43.33,0.0054776,-0.12263249999999999,45.6,1.8633623895039289,13.360219893876597,4.1678901763946614e-11,0.0009999900021016987,60.75597307176595,19.89314705919883,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B144-TF-525,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,525.0,489.3,2.58,,,72.0,13.36,49.25,12.12,43.33,0.0065464,-0.13543750000000002,44.7,1.9441726937408566,13.360195694456245,1.2592413071394484e-10,0.00099999006867769,68.2690127583781,18.459294347605976,-0.36,N,2025.7.3,6/23/2025,2.0,bootstrapping +GOLDI SUN PRIVATE LIMITED GS10-M144-BF-525,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,525.0,492.9,2.58,,,72.0,13.36,49.25,12.12,43.33,0.00358048,-0.120367,45.19,1.8014832505924823,13.3603908657867,1.6729583835150315e-11,0.0016509981526353517,56.43199299748775,13.689054925398892,-0.3159,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-WF-525,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,525.0,491.1,2.58,,,72.0,13.36,49.25,12.12,43.33,0.00395456,-0.122731,44.87,1.8572075511693258,13.360221675924052,3.8163495605695865e-11,0.0009999900620598326,60.26756071110371,19.101014886376735,-0.3388,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B144-GF-530,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,530.0,495.3,2.58,,,72.0,13.39,49.32,12.17,43.56,0.005489900000000001,-0.12280680000000001,45.6,1.8604788601894744,13.390197825931885,3.8872425836098655e-11,0.0009999900293175133,67.68509255515077,19.17101958727111,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B144-TF-530,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,530.0,494.1,2.58,,,72.0,13.39,49.32,12.17,43.56,0.006561100000000001,-0.13563000000000003,44.7,1.7323337332560294,13.390235582490854,5.410194274227491e-12,0.0010000186724220138,56.83890164155354,-8.214449567654995,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-BF-530,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,530.0,497.7,2.58,,,72.0,13.39,49.32,12.17,43.56,0.0035885200000000004,-0.12053808,45.19,1.7993407594059103,13.390216343235446,1.570769232158921e-11,0.0009999900062380024,61.891771946990275,13.06381340507158,-0.3159,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-WF-530,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,530.0,495.9,2.58,,,72.0,13.39,49.32,12.17,43.56,0.00396344,-0.12290544,44.87,1.8542997148316904,13.390199738389878,3.556602915873956e-11,0.0009999900060239455,67.03701880054018,18.376867022069984,-0.3388,N,2025.7.3,6/23/2025,2.0,bootstrapping +GOLDI SUN PRIVATE LIMITED GS10-B144-GF-535,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,535.0,500.1,2.58,,,72.0,13.41,49.39,12.26,43.64,0.0054981,-0.1229811,45.6,1.7310887904469083,13.410212328828946,5.133446108771414e-12,0.0010000172986653773,63.157848343994225,1.087217479898642,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B144-TF-535,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,535.0,498.9,2.58,,,72.0,13.41,49.39,12.26,43.64,0.0065709,-0.1358225,44.7,1.9376001096309257,13.410148835838038,1.0939882984052573e-10,0.0009999900404402224,90.09837070756096,17.03567783722652,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-BF-535,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,535.0,502.5,2.58,,,72.0,13.41,49.39,12.26,43.64,0.0035938800000000003,-0.12070916000000001,45.19,1.7967361959023418,13.410193278327212,1.4640026576477025e-11,0.0009999900064917033,69.38111576073518,12.3784221461007,-0.3159,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-WF-535,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,535.0,500.7,2.58,,,72.0,13.41,49.39,12.26,43.64,0.00396936,-0.12307988,44.87,1.7270564074472652,13.410418114025626,4.744539596745071e-12,0.0019708227621300935,63.07323143779081,1.0043948618049854,-0.3388,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-B144-TF-540,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,540.0,503.7,2.58,,,72.0,13.45,49.46,12.31,43.88,0.006590500000000001,-0.13601500000000002,44.7,1.776304051852549,13.450736998738371,8.150814307023788e-12,0.0039920516048402716,72.27208110015091,-18.522436171349337,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-BF-540,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,540.0,507.3,2.58,,,72.0,13.45,49.46,12.31,43.88,0.0036046000000000003,-0.12088024000000001,45.19,1.7943686408365953,13.450172999390993,1.3702058969695199e-11,0.0009999900202706563,77.74516258801182,11.723919060747445,-0.3159,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-M144-WF-540,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,0,540.0,505.5,2.58,,,72.0,13.45,49.46,12.31,43.88,0.003981200000000001,-0.12325432000000001,44.87,1.848677934530442,13.450155172158707,3.095101854091882e-11,0.000999990122520408,86.67706422668002,16.95895934879101,-0.3388,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-555,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,555.0,524.2,2.58,,,72.0,14.08,50.48,13.16,42.2,0.00340736,-0.11014736000000001,45.48,1.7005735753610578,14.106391561069074,1.7538790545394927e-12,0.21485459510485524,114.62575815798505,5.338542745971479,-0.2889,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-560,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,560.0,529.0,2.58,,,72.0,14.12,50.68,13.21,42.4,0.0034170399999999997,-0.11058376,45.48,1.7071888487276894,14.14520032256581,1.7569632129281935e-12,0.21231644186380577,118.96308680353422,5.324552085069083,-0.2889,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-565,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,565.0,533.8,2.58,,,72.0,14.18,50.88,13.27,42.6,0.00343156,-0.11102016,45.48,1.7143041935794274,14.204722681167667,1.776507220648773e-12,0.2094736652302986,120.14621528261672,5.383147403623342,-0.2889,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-570,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,570.0,538.7,2.58,,,72.0,14.24,51.08,13.32,42.8,0.00344608,-0.11145656000000001,45.48,1.721995134860996,14.264988728329735,1.8124501586662595e-12,0.206621478982237,117.74468110059863,5.524397234244012,-0.2889,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-575,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,575.0,539.2,2.58,,,72.0,13.58,52.89,12.67,45.45,0.0037345,-0.13391748,45.2,1.9301915872871445,13.591158449925025,1.655273706423711e-11,0.1001032056256308,121.82709472910908,9.318240994980197,-0.3333,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-580,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,580.0,544.0,2.58,,,72.0,13.61,52.95,12.75,45.5,0.00374275,-0.1340694,45.2,1.9283786926299658,13.619610277940074,1.574758948251138e-11,0.10104305689678299,143.09638263865506,8.83823424411635,-0.3333,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-585,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,585.0,548.8,2.58,,,72.0,13.64,53.1,12.85,45.55,0.0037510000000000004,-0.1344492,45.2,1.9268106136134908,13.64784696341362,1.4373964408697254e-11,0.10930714022709932,190.00335752346632,7.988774314504083,-0.3333,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-590,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,590.0,553.6,2.58,,,72.0,13.65,53.13,12.88,45.85,0.00375375,-0.13452515999999998,45.2,1.9320849843219736,13.655683616084996,1.5290401120747585e-11,0.08535872200857286,205.00092562194374,8.519357878900175,-0.3333,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS10-T144-GF-595,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,595.0,558.5,2.58,,,72.0,13.66,53.17,12.95,45.95,0.0037565,-0.13462644,45.2,1.9304328918672933,13.66384214289829,1.471794638452852e-11,0.08066364417606134,286.78407124941907,8.15522430474952,-0.3333,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-600,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,600.0,564.3,2.7,,,66.0,15.8,48.4,14.89,40.3,0.0071574,-0.1124332,46.98,1.6720912349389379,15.819033998225835,4.164852051109748e-12,0.1883300842407483,156.33159670020177,4.883409395026403,-0.2918,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-605,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,605.0,569.1,2.7,,,66.0,15.83,48.7,14.94,40.5,0.0071709899999999995,-0.11313010000000001,46.98,1.6803893123377347,15.84759553233367,4.034168431413343e-12,0.1929708957139014,173.60823331946614,4.583735834458881,-0.2918,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-610,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,610.0,573.9,2.7,,,66.0,15.86,49.0,14.99,40.7,0.0071845799999999994,-0.113827,46.98,1.6886886250880047,15.876074743433984,3.908980400057795e-12,0.197580484111287,194.9409913514004,4.2879250100285,-0.2918,N,2025.7.3,6/23/2025,2.0,first_pass +GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-615,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,615.0,578.8,2.7,,,66.0,15.89,49.3,15.04,40.9,0.00719817,-0.1145239,46.98,1.6969892355708007,15.90447326127446,3.789013543230353e-12,0.20215915254680203,221.94783000736476,3.9959152546180596,-0.2918,N,2025.7.3,6/23/2025,4.0,first_pass +GOLDI SUN PRIVATE LIMITED GS12R-T132-GF-620,GOLDI SUN PRIVATE LIMITED,Mono-c-Si,1,620.0,583.6,2.7,,,66.0,15.92,49.6,15.09,41.1,0.00721176,-0.11522080000000001,46.98,1.7052911456624267,15.93279268333003,3.6740053955757185e-12,0.2067072091643895,257.23913283226295,3.7076377112509724,-0.2918,N,2025.7.3,6/23/2025,4.0,first_pass +Grape Solar GS-P-200-CSPE,Grape Solar,Multi-c-Si,0,200.0,177.1,1.6085159999999998,1.638,0.982,60.0,7.68,36.2,6.93,28.9,0.009984,-0.13394,49.1,1.6130879918997343,7.715201981926332,1.3060904055638626e-09,0.38171392957311945,83.27836614499273,10.003107362993806,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Grape Solar GS-P-220-CS,Grape Solar,Multi-c-Si,0,220.0,201.6,1.6085159999999998,1.638,0.982,60.0,8.09,36.6,7.52,29.3,0.0029124,-0.127002,43.6,1.4493350955693902,8.10817167046645,8.521490370863418e-11,0.39872516485546994,177.51184265485858,-5.3675694204599065,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Grape Solar GS-S-220-CS,Grape Solar,Mono-c-Si,0,220.0,200.1,1.699722,1.602,1.061,96.0,5.1,59.4,4.69,46.9,0.004539,-0.222156,42.4,2.6169398697956012,5.114594937830915,6.87745479972698e-10,1.0740497788418588,375.31202741988045,7.174525584544631,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +Grape Solar GS-P-230-CS,Grape Solar,Multi-c-Si,0,230.0,211.0,1.6085159999999998,1.638,0.982,60.0,8.34,36.8,7.71,29.8,0.0030023999999999997,-0.12769599999999998,43.6,1.4710733857749447,8.361302564892561,1.1049532066208971e-10,0.33712629247099557,131.9856729680889,-3.5842372727422216,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Grape Solar GS-S-230-CS,Grape Solar,Mono-c-Si,0,230.0,209.4,1.699722,1.602,1.061,96.0,5.25,58.8,4.84,47.5,0.0046725,-0.219912,42.4,2.623996674227183,5.260837062022375,9.459535861136192e-10,0.766728287118058,371.44059680721654,9.74885807094379,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +Grape Solar GS-S-240-CS,Grape Solar,Mono-c-Si,0,240.0,218.7,1.699722,1.602,1.061,96.0,5.4,59.3,4.99,48.8,0.004806,-0.22178199999999998,42.4,2.6731589063621914,5.407641788904033,1.219351594282301e-09,0.5380263380375199,380.19149344568996,11.799636710181364,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +Greenlite Solar Canada GLS-200,Greenlite Solar Canada,Multi-c-Si,0,200.0,180.0,1.459252,1.486,0.982,54.0,7.95,33.37,7.45,27.54,0.010335,-0.10010999999999999,46.2,1.4539285825903718,7.955287406924012,8.453141267026934e-10,0.2074280078607465,311.88316423927165,30.923995697480077,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Greenlite Solar Canada GLS-220,Greenlite Solar Canada,Multi-c-Si,0,220.0,197.9,1.6144079999999998,1.644,0.982,60.0,7.95,37.08,7.45,30.6,0.010335,-0.11123999999999999,46.2,1.615520791752387,7.955291603101958,8.44692859163212e-10,0.23077916914020863,346.71818269014193,30.916045209130395,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Greenlite Solar Canada GLS-270,Greenlite Solar Canada,Multi-c-Si,0,270.0,243.1,1.92472,1.96,0.982,72.0,7.95,44.49,7.45,36.72,0.010335,-0.13347,46.2,1.9385047601056993,7.95528214745694,8.460934134055462e-10,0.27611521848724596,415.57278442494936,30.933960742725866,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Grenzebach Envelon GmbH ON Generate-36-S1,Grenzebach Envelon GmbH,Mono-c-Si,0,185.0,168.4,1.13,,,18.0,9.6,24.28,9.17,20.17,0.0035328,-0.06541032,49.45,0.8986017869921611,9.600001381106207,1.769048581506762e-11,0.1438541714954218,999987.7029600567,5.958181846414887,-0.3578,Y,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSP6G60M(H)355BT,G-Star Pte Ltd,Mono-c-Si,0,355.0,334.5,1.81,,,60.0,11.1,40.5,10.45,34.0,0.0046287,-0.12105450000000001,43.2,1.4784451200607616,11.110329422463241,1.3818759678668654e-11,0.17815034553599246,191.4404071080659,-7.537966225603162,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)355WT,G-Star Pte Ltd,Mono-c-Si,0,355.0,334.5,1.81,,,60.0,11.1,40.5,10.45,34.0,0.0046287,-0.12105450000000001,43.2,1.4784451200607616,11.110329422463241,1.3818759678668654e-11,0.17815034553599246,191.4404071080659,-7.537966225603162,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)360BT,G-Star Pte Ltd,Mono-c-Si,0,360.0,339.3,1.81,,,60.0,11.15,40.7,10.5,34.3,0.0046495500000000006,-0.1216523,43.2,1.4885029323867611,11.159510636261228,1.4603092102070157e-11,0.16383009194412462,192.06975030521443,-7.156275087915392,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)360WT,G-Star Pte Ltd,Mono-c-Si,0,360.0,339.3,1.81,,,60.0,11.15,40.7,10.5,34.3,0.0046495500000000006,-0.1216523,43.2,1.4885029323867611,11.159510636261228,1.4603092102070157e-11,0.16383009194412462,192.06975030521443,-7.156275087915392,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)365BT,G-Star Pte Ltd,Mono-c-Si,0,365.0,344.1,1.81,,,60.0,11.2,40.9,10.56,34.6,0.0046704,-0.12225009999999999,43.2,1.4978408985632776,11.208181040826299,1.5237187335840956e-11,0.14978960138564237,205.06480502798843,-6.872693927188919,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)365WT,G-Star Pte Ltd,Mono-c-Si,0,365.0,344.1,1.81,,,60.0,11.2,40.9,10.56,34.6,0.0046704,-0.12225009999999999,43.2,1.4978408985632776,11.208181040826299,1.5237187335840956e-11,0.14978960138564237,205.06480502798843,-6.872693927188919,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)370BT,G-Star Pte Ltd,Mono-c-Si,0,370.0,348.9,1.81,,,60.0,11.26,41.1,10.61,34.9,0.0046954200000000005,-0.12284790000000001,43.2,1.50855554459341,11.267865526548283,1.6271076768922117e-11,0.13550818696657907,193.9885627988406,-6.412303846030665,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)370WT,G-Star Pte Ltd,Mono-c-Si,0,370.0,348.9,1.81,,,60.0,11.26,41.1,10.61,34.9,0.0046954200000000005,-0.12284790000000001,43.2,1.50855554459341,11.267865526548283,1.6271076768922117e-11,0.13550818696657907,193.9885627988406,-6.412303846030665,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)375BT,G-Star Pte Ltd,Mono-c-Si,0,375.0,353.7,1.81,,,60.0,11.31,41.3,10.66,35.2,0.004716270000000001,-0.12344569999999999,43.2,1.5185919339937468,11.317062623430658,1.715298647354339e-11,0.12162739484327548,194.7726442033945,-6.044437515830382,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)375WT,G-Star Pte Ltd,Mono-c-Si,0,375.0,353.7,1.81,,,60.0,11.31,41.3,10.66,35.2,0.004716270000000001,-0.12344569999999999,43.2,1.5185919339937468,11.317062623430658,1.715298647354339e-11,0.12162739484327548,194.7726442033945,-6.044437515830382,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)380BT,G-Star Pte Ltd,Mono-c-Si,0,380.0,358.6,1.81,,,60.0,11.37,41.5,10.71,35.5,0.00474129,-0.12404350000000001,43.2,1.5293083851850973,11.376610573730437,1.8287670574956902e-11,0.10761934646357607,185.1022351972573,-5.592198219473697,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)380WT,G-Star Pte Ltd,Mono-c-Si,0,380.0,358.6,1.81,,,60.0,11.37,41.5,10.71,35.5,0.00474129,-0.12404350000000001,43.2,1.5293083851850973,11.376610573730437,1.8287670574956902e-11,0.10761934646357607,185.1022351972573,-5.592198219473697,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)385BT,G-Star Pte Ltd,Mono-c-Si,0,385.0,363.4,1.81,,,60.0,11.42,41.7,10.76,35.8,0.00476214,-0.12464130000000001,43.2,1.553968929367183,11.420002455067475,2.5326860520169683e-11,0.09065130962620536,421678.050878134,-3.1720191019668307,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP6G60M(H)385WT,G-Star Pte Ltd,Mono-c-Si,0,385.0,363.4,1.81,,,60.0,11.42,41.7,10.76,35.8,0.00476214,-0.12464130000000001,43.2,1.553968929367183,11.420002455067475,2.5326860520169683e-11,0.09065130962620536,421678.050878134,-3.1720191019668307,-0.3273,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)390BB,G-Star Pte Ltd,Mono-c-Si,0,390.0,367.0,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00676417,-0.095922,43.4,1.3488327587665792,13.627158219465308,2.3472443028500953e-11,0.12757921229465694,101.19657739380264,7.978403971629481,-0.3329,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSP7F54M(H)390BW,G-Star Pte Ltd,Mono-c-Si,0,390.0,367.0,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00676417,-0.095922,43.4,1.3488327587665792,13.627158219465308,2.3472443028500953e-11,0.12757921229465694,101.19657739380264,7.978403971629481,-0.3329,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD7G54M-395BT,G-Star Pte Ltd,Mono-c-Si,0,395.0,372.1,1.94,,,54.0,13.69,36.75,12.81,30.85,0.0060646699999999994,-0.10877999999999999,43.2,1.356914689165146,13.707081716544161,2.3083200925513403e-11,0.12874469328297097,103.18136668128226,-4.3147213965946,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-395WT,G-Star Pte Ltd,Mono-c-Si,0,395.0,372.1,1.94,,,54.0,13.69,36.75,12.81,30.85,0.0060646699999999994,-0.10877999999999999,43.2,1.356914689165146,13.707081716544161,2.3083200925513403e-11,0.12874469328297097,103.18136668128226,-4.3147213965946,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)395BB,G-Star Pte Ltd,Mono-c-Si,0,395.0,371.8,1.95,,,54.0,13.69,36.75,12.81,30.85,0.00680393,-0.09657899999999998,43.4,1.3575781642501843,13.70705100989483,2.3391272357565183e-11,0.12862858258003226,103.27395935689724,7.894825779567367,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)395BW,G-Star Pte Ltd,Mono-c-Si,0,395.0,371.8,1.95,,,54.0,13.69,36.75,12.81,30.85,0.00680393,-0.09657899999999998,43.4,1.3575781642501843,13.70705100989483,2.3391272357565183e-11,0.12862858258003226,103.27395935689724,7.894825779567367,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-400BT,G-Star Pte Ltd,Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.78,37.0,12.89,31.05,0.00610454,-0.10951999999999999,43.2,1.366144671777666,13.79755555136457,2.322635978313401e-11,0.12962412016306465,101.74675494763247,-4.316458252117646,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-400WT,G-Star Pte Ltd,Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.78,37.0,12.89,31.05,0.00610454,-0.10951999999999999,43.2,1.366144671777666,13.79755555136457,2.322635978313401e-11,0.12962412016306465,101.74675494763247,-4.316458252117646,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)400BB,G-Star Pte Ltd,Mono-c-Si,0,400.0,376.6,1.95,,,54.0,13.78,37.0,12.89,31.05,0.00684866,-0.09723599999999999,43.4,1.3668130150161433,13.79752429301996,2.353650761877491e-11,0.12950790114687316,101.83685482877313,7.892927721859162,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)400BW,G-Star Pte Ltd,Mono-c-Si,0,400.0,376.6,1.95,,,54.0,13.78,37.0,12.89,31.05,0.00684866,-0.09723599999999999,43.4,1.3668130150161433,13.79752429301996,2.353650761877491e-11,0.12950790114687316,101.83685482877313,7.892927721859162,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-405BT,G-Star Pte Ltd,Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.86,37.25,12.97,31.24,0.00613998,-0.11026,43.2,1.3746417981462318,13.877546901985816,2.3038132919337974e-11,0.1315375690690041,103.899293225996,-4.426166175079907,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-405WT,G-Star Pte Ltd,Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.86,37.25,12.97,31.24,0.00613998,-0.11026,43.2,1.3746417981462318,13.877546901985816,2.3038132919337974e-11,0.1315375690690041,103.899293225996,-4.426166175079907,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)405BB,G-Star Pte Ltd,Mono-c-Si,0,405.0,381.4,1.95,,,54.0,13.86,37.25,12.97,31.24,0.00688842,-0.097893,43.4,1.3753345023456671,13.877514603299623,2.3355239484061024e-11,0.13141792212676875,103.9962125868816,7.772590228540256,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)405BW,G-Star Pte Ltd,Mono-c-Si,0,405.0,381.4,1.95,,,54.0,13.86,37.25,12.97,31.24,0.00688842,-0.097893,43.4,1.3753345023456671,13.877514603299623,2.3355239484061024e-11,0.13141792212676875,103.9962125868816,7.772590228540256,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-410BT,G-Star Pte Ltd,Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.94,37.5,13.05,31.43,0.00617542,-0.11099999999999999,43.2,1.3831394206321523,13.957527478850603,2.2854807964145017e-11,0.1334274666092022,106.11787965153164,-4.534336631884555,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-410WT,G-Star Pte Ltd,Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.94,37.5,13.05,31.43,0.00617542,-0.11099999999999999,43.2,1.3831394206321523,13.957527478850603,2.2854807964145017e-11,0.1334274666092022,106.11787965153164,-4.534336631884555,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)410BB,G-Star Pte Ltd,Mono-c-Si,0,410.0,386.2,1.95,,,54.0,13.94,37.5,13.05,31.43,0.00692818,-0.09855,43.4,1.383856393592687,13.9574941496402,2.3178643538135847e-11,0.13330445334591554,106.22202992463468,7.653926223976022,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7F54M(H)410BW,G-Star Pte Ltd,Mono-c-Si,0,410.0,386.2,1.95,,,54.0,13.94,37.5,13.05,31.43,0.00692818,-0.09855,43.4,1.383856393592687,13.9574941496402,2.3178643538135847e-11,0.13330445334591554,106.22202992463468,7.653926223976022,-0.3329,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-415BT,G-Star Pte Ltd,Mono-c-Si,0,415.0,391.4,1.94,,,54.0,14.02,37.75,13.13,31.64,0.0062108599999999995,-0.11173999999999999,43.2,1.39209741146463,14.03730107060244,2.2878998849082694e-11,0.1335428205500032,108.21702258238537,-4.571912449081721,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G54M-415WT,G-Star Pte Ltd,Mono-c-Si,0,415.0,391.4,1.94,,,54.0,14.02,37.75,13.13,31.64,0.0062108599999999995,-0.11173999999999999,43.2,1.39209741146463,14.03730107060244,2.2878998849082694e-11,0.1335428205500032,108.21702258238537,-4.571912449081721,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSP7F54M(H)415BB,G-Star Pte Ltd,Mono-c-Si,0,415.0,391.1,1.95,,,54.0,14.02,37.75,13.13,31.64,0.00696794,-0.09920699999999999,43.4,1.3928261218365505,14.037267524968717,2.3206447888124324e-11,0.13341856493267037,108.32636934705012,7.61272224436498,-0.3329,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSP7F54M(H)415BW,G-Star Pte Ltd,Mono-c-Si,0,415.0,391.1,1.95,,,54.0,14.02,37.75,13.13,31.64,0.00696794,-0.09920699999999999,43.4,1.3928261218365505,14.037267524968717,2.3206447888124324e-11,0.13341856493267037,108.32636934705012,7.61272224436498,-0.3329,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G54M-420BT,G-Star Pte Ltd,Mono-c-Si,0,420.0,396.3,1.94,,,54.0,14.1,38.0,13.22,31.79,0.006246299999999999,-0.11248,43.2,1.399144252162684,14.116988199472216,2.2094361836220997e-11,0.13893845141831457,115.3172339136496,-4.890491972237426,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G54M-420WT,G-Star Pte Ltd,Mono-c-Si,0,420.0,396.3,1.94,,,54.0,14.1,38.0,13.22,31.79,0.006246299999999999,-0.11248,43.2,1.399144252162684,14.116988199472216,2.2094361836220997e-11,0.13893845141831457,115.3172339136496,-4.890491972237426,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-420BT,G-Star Pte Ltd,Mono-c-Si,0,420.0,399.2,1.94,,,54.0,13.42,39.41,12.84,32.72,0.0058511200000000005,-0.08879072999999998,43.1,1.3476369174312273,13.420701538711302,2.6730720002576235e-12,0.18975213251809278,3629.8405053154443,5.63699941322711,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-420WT,G-Star Pte Ltd,Mono-c-Si,0,420.0,399.2,1.94,,,54.0,13.42,39.41,12.84,32.72,0.0058511200000000005,-0.08879072999999998,43.1,1.3476369174312273,13.420701538711302,2.6730720002576235e-12,0.18975213251809278,3629.8405053154443,5.63699941322711,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-425BT,G-Star Pte Ltd,Mono-c-Si,0,425.0,404.0,1.94,,,54.0,13.51,39.56,12.92,32.9,0.00589036,-0.08912868,43.1,1.352741770481925,13.510005585184198,2.691597515946834e-12,0.18454391622642807,446394.3546394483,5.635812347997323,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-425WT,G-Star Pte Ltd,Mono-c-Si,0,425.0,404.0,1.94,,,54.0,13.51,39.56,12.92,32.9,0.00589036,-0.08912868,43.1,1.352741770481925,13.510005585184198,2.691597515946834e-12,0.18454391622642807,446394.3546394483,5.635812347997323,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-430BT,G-Star Pte Ltd,Mono-c-Si,0,430.0,408.9,1.94,,,54.0,13.6,39.71,13.0,33.08,0.0059296,-0.08946663,43.1,1.3585340062142774,13.600005358336738,2.748478118645625e-12,0.17929343260753958,455066.0175625264,5.760925156780353,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-430WT,G-Star Pte Ltd,Mono-c-Si,0,430.0,408.9,1.94,,,54.0,13.6,39.71,13.0,33.08,0.0059296,-0.08946663,43.1,1.3585340062142774,13.600005358336738,2.748478118645625e-12,0.17929343260753958,455066.0175625264,5.760925156780353,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-435BT,G-Star Pte Ltd,Mono-c-Si,0,435.0,413.8,1.94,,,54.0,13.69,39.86,13.08,33.26,0.0059688399999999996,-0.08980458000000001,43.1,1.366970491651264,13.692468976406312,2.9608270683650457e-12,0.17369210618152592,963.0900035017233,6.36911176993245,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-435WT,G-Star Pte Ltd,Mono-c-Si,0,435.0,413.8,1.94,,,54.0,13.69,39.86,13.08,33.26,0.0059688399999999996,-0.08980458000000001,43.1,1.366970491651264,13.692468976406312,2.9608270683650457e-12,0.17369210618152592,963.0900035017233,6.36911176993245,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-440BT,G-Star Pte Ltd,Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.78,40.01,13.16,33.44,0.00600808,-0.09014253,43.1,1.373414770755495,13.782987138311556,3.061626572846954e-12,0.16847039292278074,777.1728990829977,6.609467602963865,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-440WT,G-Star Pte Ltd,Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.78,40.01,13.16,33.44,0.00600808,-0.09014253,43.1,1.373414770755495,13.782987138311556,3.061626572846954e-12,0.16847039292278074,777.1728990829977,6.609467602963865,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-440BT,G-Star Pte Ltd,Mono-c-Si,0,440.0,418.4,1.98,,,16.0,15.73,35.15,14.96,29.42,0.00655941,-0.08312974999999999,43.1,1.2097710829607602,15.737960359921468,3.754772269633907e-12,0.12635392270025742,249.68057067680394,2.180086864832445,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8R48T-440WT,G-Star Pte Ltd,Mono-c-Si,0,440.0,418.4,1.98,,,16.0,15.73,35.15,14.96,29.42,0.00655941,-0.08312974999999999,43.1,1.2097710829607602,15.737960359921468,3.754772269633907e-12,0.12635392270025742,249.68057067680394,2.180086864832445,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S54T-445BT,G-Star Pte Ltd,Mono-c-Si,0,445.0,423.5,1.94,,,54.0,13.87,40.16,13.24,33.62,0.006047319999999999,-0.09048047999999999,43.1,1.3798589099570227,13.873470753948583,3.1649250109396032e-12,0.1633124863793181,652.6375051871001,6.848013535036039,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-445WT,G-Star Pte Ltd,Mono-c-Si,0,445.0,423.5,1.94,,,54.0,13.87,40.16,13.24,33.62,0.006047319999999999,-0.09048047999999999,43.1,1.3798589099570227,13.873470753948583,3.1649250109396032e-12,0.1633124863793181,652.6375051871001,6.848013535036039,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-445BT,G-Star Pte Ltd,Mono-c-Si,0,445.0,423.3,1.98,,,16.0,15.78,35.36,15.01,29.65,0.00658026,-0.0836264,43.1,1.217949009385278,15.787689406870674,3.853170274341412e-12,0.12260890011932092,251.61478384428904,2.3719166353734598,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-445WT,G-Star Pte Ltd,Mono-c-Si,0,445.0,423.3,1.98,,,16.0,15.78,35.36,15.01,29.65,0.00658026,-0.0836264,43.1,1.217949009385278,15.787689406870674,3.853170274341412e-12,0.12260890011932092,251.61478384428904,2.3719166353734598,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-450BT,G-Star Pte Ltd,Mono-c-Si,0,450.0,428.3,1.94,,,54.0,13.96,40.31,13.32,33.79,0.00608656,-0.09081843,43.1,1.3861150574199417,13.963921185379178,3.2579808892519757e-12,0.15906855579241688,566.307591507466,7.049972950669996,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-450WT,G-Star Pte Ltd,Mono-c-Si,0,450.0,428.3,1.94,,,54.0,13.96,40.31,13.32,33.79,0.00608656,-0.09081843,43.1,1.3861150574199417,13.963921185379178,3.2579808892519757e-12,0.15906855579241688,566.307591507466,7.049972950669996,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-450BT,G-Star Pte Ltd,Mono-c-Si,0,450.0,428.2,1.98,,,16.0,15.83,35.57,15.06,29.89,0.00660111,-0.08412305,43.1,1.2263162112970956,15.837397118241187,3.970540679136129e-12,0.11813657061050822,252.81492811079448,2.5993214130753555,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8R48T-450WT,G-Star Pte Ltd,Mono-c-Si,0,450.0,428.2,1.98,,,16.0,15.83,35.57,15.06,29.89,0.00660111,-0.08412305,43.1,1.2263162112970956,15.837397118241187,3.970540679136129e-12,0.11813657061050822,252.81492811079448,2.5993214130753555,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S54T-455BT,G-Star Pte Ltd,Mono-c-Si,0,455.0,433.2,1.94,,,54.0,14.05,40.46,13.4,33.97,0.006125800000000001,-0.09115638000000001,43.1,1.3925588839673784,14.054341117819247,3.366030721955105e-12,0.1540296025998451,498.51582336146816,7.285080947805631,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S54T-455WT,G-Star Pte Ltd,Mono-c-Si,0,455.0,433.2,1.94,,,54.0,14.05,40.46,13.4,33.97,0.006125800000000001,-0.09115638000000001,43.1,1.3925588839673784,14.054341117819247,3.366030721955105e-12,0.1540296025998451,498.51582336146816,7.285080947805631,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-455BT,G-Star Pte Ltd,Mono-c-Si,0,455.0,433.0,1.98,,,16.0,15.88,35.78,15.11,30.12,0.006621960000000001,-0.08461969999999999,43.1,1.234490183839981,15.88713045576807,4.071577788859467e-12,0.11444631674420191,254.87957186724813,2.78567625710371,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8R48T-455WT,G-Star Pte Ltd,Mono-c-Si,0,455.0,433.0,1.98,,,16.0,15.88,35.78,15.11,30.12,0.006621960000000001,-0.08461969999999999,43.1,1.234490183839981,15.88713045576807,4.071577788859467e-12,0.11444631674420191,254.87957186724813,2.78567625710371,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8R48T-460BT,G-Star Pte Ltd,Mono-c-Si,0,460.0,437.9,1.98,,,16.0,15.93,35.99,15.16,30.35,0.00664281,-0.08511635000000001,43.1,1.2426623282716913,15.936866542392238,4.173769242630459e-12,0.11078165407503826,257.00733393069527,2.969505651439742,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-460WT,G-Star Pte Ltd,Mono-c-Si,0,460.0,437.9,1.98,,,16.0,15.93,35.99,15.16,30.35,0.00664281,-0.08511635000000001,43.1,1.2426623282716913,15.936866542392238,4.173769242630459e-12,0.11078165407503826,257.00733393069527,2.969505651439742,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-465BT,G-Star Pte Ltd,Mono-c-Si,0,465.0,442.8,1.98,,,16.0,15.98,36.2,15.21,30.58,0.00666366,-0.08561300000000001,43.1,1.2508326647208916,15.986605500488642,4.277103926267602e-12,0.10714230495643938,259.19823033726345,3.1508573112693132,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-465WT,G-Star Pte Ltd,Mono-c-Si,0,465.0,442.8,1.98,,,16.0,15.98,36.2,15.21,30.58,0.00666366,-0.08561300000000001,43.1,1.2508326647208916,15.986605500488642,4.277103926267602e-12,0.10714230495643938,259.19823033726345,3.1508573112693132,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-470BT,G-Star Pte Ltd,Mono-c-Si,0,470.0,447.6,1.98,,,16.0,16.03,36.41,15.23,30.87,0.006684510000000001,-0.08610965,43.1,1.2612651009595548,16.03783185353535,4.6036881666621045e-12,0.0989483643026211,202.5245077627239,3.762287012994008,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R48T-470WT,G-Star Pte Ltd,Mono-c-Si,0,470.0,447.6,1.98,,,16.0,16.03,36.41,15.23,30.87,0.006684510000000001,-0.08610965,43.1,1.2612651009595548,16.03783185353535,4.6036881666621045e-12,0.0989483643026211,202.5245077627239,3.762287012994008,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7G72M(H)525WT,G-Star Pte Ltd,Mono-c-Si,1,525.0,493.0,2.56,,,72.0,13.65,49.18,12.76,41.16,0.003972150000000001,-0.12673686,43.1,1.814336354150693,13.668797817777921,2.2476740006902035e-11,0.18381478590120018,133.4767612960199,9.997578419135134,-0.3519,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-530BT,G-Star Pte Ltd,Mono-c-Si,0,530.0,499.5,2.56,,,72.0,13.72,49.32,12.83,41.32,0.00607796,-0.1459872,43.2,1.8197260432982525,13.738270950300537,2.267486667646798e-11,0.179672615272109,134.91954440233255,-4.4683506733218294,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G72M-530WT,G-Star Pte Ltd,Mono-c-Si,0,530.0,499.5,2.56,,,72.0,13.72,49.32,12.83,41.32,0.00607796,-0.1459872,43.2,1.8197260432982525,13.738270950300537,2.267486667646798e-11,0.179672615272109,134.91954440233255,-4.4683506733218294,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSP7G72M(H)530WT,G-Star Pte Ltd,Mono-c-Si,1,530.0,497.9,2.56,,,72.0,13.72,49.32,12.83,41.32,0.00399252,-0.12709764,43.1,1.820138440573644,13.73825618607622,2.281476707380746e-11,0.1796006448440112,134.9745694875289,10.083656448369666,-0.3519,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G72M-535BT,G-Star Pte Ltd,Mono-c-Si,0,535.0,504.3,2.56,,,72.0,13.7,49.46,12.9,41.48,0.006069099999999999,-0.1464016,43.2,1.8195529484452198,13.71236687267327,2.107934465396786e-11,0.17739876490579015,196.5220436240133,-5.046624376337139,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-535WT,G-Star Pte Ltd,Mono-c-Si,0,535.0,504.3,2.56,,,72.0,13.7,49.46,12.9,41.48,0.006069099999999999,-0.1464016,43.2,1.8195529484452198,13.71236687267327,2.107934465396786e-11,0.17739876490579015,196.5220436240133,-5.046624376337139,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7G72M(H)535WT,G-Star Pte Ltd,Mono-c-Si,1,535.0,502.7,2.56,,,72.0,13.79,49.46,12.9,41.48,0.00401289,-0.12745842,43.1,1.82594078327327,13.807724028679187,2.315588618986321e-11,0.17543264898122674,136.49358640473702,10.169271594122405,-0.3519,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-540BT,G-Star Pte Ltd,Mono-c-Si,0,540.0,509.1,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00613998,-0.146816,43.2,1.831375778261471,13.877213939614755,2.337251502868933e-11,0.17137358820927404,137.98340139691373,-4.314082175470979,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-540WT,G-Star Pte Ltd,Mono-c-Si,0,540.0,509.1,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00613998,-0.146816,43.2,1.831375778261471,13.877213939614755,2.337251502868933e-11,0.17137358820927404,137.98340139691373,-4.314082175470979,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7G72M(H)540WT,G-Star Pte Ltd,Mono-c-Si,1,540.0,507.5,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00403326,-0.1278192,43.1,1.8317433687309879,13.877201212960715,2.3500100002793624e-11,0.17131004662541024,138.03429213177745,10.254427635608106,-0.3519,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-545BT,G-Star Pte Ltd,Mono-c-Si,0,545.0,514.0,2.56,,,72.0,13.93,49.76,13.04,41.8,0.00617099,-0.1472896,43.2,1.837553124000433,13.946829654181046,2.35923489855557e-11,0.16884037833965385,139.75013715825068,-4.28163306658345,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-545WT,G-Star Pte Ltd,Mono-c-Si,0,545.0,514.0,2.56,,,72.0,13.93,49.76,13.04,41.8,0.00617099,-0.1472896,43.2,1.837553124000433,13.946829654181046,2.35923489855557e-11,0.16884037833965385,139.75013715825068,-4.28163306658345,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7G72M(H)545WT,G-Star Pte Ltd,Mono-c-Si,1,545.0,512.3,2.56,,,72.0,13.93,49.76,13.04,41.8,0.00405363,-0.12823152,43.1,1.8379107909203036,13.94681741611793,2.3717208509108804e-11,0.16877886137749343,139.80087851192533,10.29013414078943,-0.3519,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G72M-550BT,G-Star Pte Ltd,Mono-c-Si,0,550.0,518.8,2.56,,,72.0,14.0,49.92,13.11,41.96,0.006202,-0.1477632,43.2,1.8437310927085808,14.016451524127895,2.3813144482511346e-11,0.16633419944490202,141.5479066069796,-4.249328322430204,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G72M-550WT,G-Star Pte Ltd,Mono-c-Si,0,550.0,518.8,2.56,,,72.0,14.0,49.92,13.11,41.96,0.006202,-0.1477632,43.2,1.8437310927085808,14.016451524127895,2.3813144482511346e-11,0.16633419944490202,141.5479066069796,-4.249328322430204,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSP7G72M(H)550WT,G-Star Pte Ltd,Mono-c-Si,1,550.0,517.1,2.56,,,72.0,14.0,49.92,13.11,41.96,0.004074,-0.12864384,43.1,1.844078884414897,14.016439777109072,2.393525497856547e-11,0.16627467952771702,141.598362710318,10.325690263613465,-0.3519,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-555BT,G-Star Pte Ltd,Mono-c-Si,0,555.0,523.6,2.56,,,72.0,14.07,50.08,13.18,42.12,0.006233010000000001,-0.1482368,43.2,1.8499097088176577,14.086079482239779,2.4034909485736424e-11,0.1638546166939671,143.3774067523548,-4.21716442689836,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G72M-555WT,G-Star Pte Ltd,Mono-c-Si,0,555.0,523.6,2.56,,,72.0,14.07,50.08,13.18,42.12,0.006233010000000001,-0.1482368,43.2,1.8499097088176577,14.086079482239779,2.4034909485736424e-11,0.1638546166939671,143.3774067523548,-4.21716442689836,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSP7G72M(H)555WT,G-Star Pte Ltd,Mono-c-Si,1,555.0,522.0,2.56,,,72.0,14.07,50.08,13.18,42.12,0.004094370000000001,-0.12905616,43.1,1.8502476449713312,14.08606821694128,2.4154238166192934e-11,0.1637970702337309,143.4275375047807,10.361098246994834,-0.3519,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-560BT,G-Star Pte Ltd,Mono-c-Si,0,560.0,528.5,2.56,,,72.0,14.14,50.24,13.25,42.28,0.0062640199999999995,-0.14871040000000002,43.2,1.8560889675816117,14.155713448469019,2.4257642421694164e-11,0.16140120860985796,145.239480886144,-4.185140393091344,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G72M-560WT,G-Star Pte Ltd,Mono-c-Si,0,560.0,528.5,2.56,,,72.0,14.14,50.24,13.25,42.28,0.0062640199999999995,-0.14871040000000002,43.2,1.8560889675816117,14.155713448469019,2.4257642421694164e-11,0.16140120860985796,145.239480886144,-4.185140393091344,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSP7G72M(H)560WT,G-Star Pte Ltd,Mono-c-Si,1,560.0,526.8,2.56,,,72.0,14.14,50.24,13.25,42.28,0.00411474,-0.12946848,43.1,1.8564170479773017,14.155702649216513,2.4374149770515593e-11,0.16134561580976964,145.28930665349532,10.396356072061524,-0.3519,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-565BT,G-Star Pte Ltd,Mono-c-Si,0,565.0,537.2,2.56,,,72.0,13.48,52.13,12.93,43.72,0.00587728,-0.11744889,43.1,1.7904699779729,13.480002796173174,3.05556330808588e-12,0.20743017509357292,999998.9764061958,6.771542811269632,-0.2928,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-565WT,G-Star Pte Ltd,Mono-c-Si,0,565.0,537.2,2.56,,,72.0,13.48,52.13,12.93,43.72,0.00587728,-0.11744889,43.1,1.7904699779729,13.480002796173174,3.05556330808588e-12,0.20743017509357292,999998.9764061958,6.771542811269632,-0.2928,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-570BT,G-Star Pte Ltd,Mono-c-Si,0,570.0,542.1,2.56,,,72.0,13.54,52.31,12.98,43.93,0.005903439999999999,-0.11785443,43.1,1.7971890798107946,13.54000276953744,3.0959696489734587e-12,0.2045439041569823,999999.4414163665,6.848438020428371,-0.2928,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-570WT,G-Star Pte Ltd,Mono-c-Si,0,570.0,542.1,2.56,,,72.0,13.54,52.31,12.98,43.93,0.005903439999999999,-0.11785443,43.1,1.7971890798107946,13.54000276953744,3.0959696489734587e-12,0.2045439041569823,999999.4414163665,6.848438020428371,-0.2928,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G78M-575BT,G-Star Pte Ltd,Mono-c-Si,0,575.0,541.9,2.77,,,78.0,13.72,53.54,12.83,44.83,0.00607796,-0.1584784,43.2,1.9748403670817307,13.738458814689956,2.249377597896888e-11,0.1973313012578387,146.671685633224,-4.530644942729886,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-575WT,G-Star Pte Ltd,Mono-c-Si,0,575.0,541.9,2.77,,,78.0,13.72,53.54,12.83,44.83,0.00607796,-0.1584784,43.2,1.9748403670817307,13.738458814689956,2.249377597896888e-11,0.1973313012578387,146.671685633224,-4.530644942729886,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-575BT,G-Star Pte Ltd,Mono-c-Si,0,575.0,546.9,2.56,,,72.0,13.6,52.49,13.03,44.14,0.0059296,-0.11825997,43.1,1.804330126982596,13.600247876202214,3.157023736277304e-12,0.20063080245743942,11007.83896148956,6.9835334680333006,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-575WT,G-Star Pte Ltd,Mono-c-Si,0,575.0,546.9,2.56,,,72.0,13.6,52.49,13.03,44.14,0.0059296,-0.11825997,43.1,1.804330126982596,13.600247876202214,3.157023736277304e-12,0.20063080245743942,11007.83896148956,6.9835334680333006,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-580BT,G-Star Pte Ltd,Mono-c-Si,0,580.0,546.8,2.77,,,78.0,13.79,53.59,12.9,44.97,0.00610897,-0.1586264,43.2,1.9785944918490497,13.807544544946449,2.3212918603079262e-11,0.18780669427607383,147.61593053028218,-4.32678267293765,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G78M-580WT,G-Star Pte Ltd,Mono-c-Si,0,580.0,546.8,2.77,,,78.0,13.79,53.59,12.9,44.97,0.00610897,-0.1586264,43.2,1.9785944918490497,13.807544544946449,2.3212918603079262e-11,0.18780669427607383,147.61593053028218,-4.32678267293765,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-580BT,G-Star Pte Ltd,Mono-c-Si,0,580.0,551.8,2.56,,,72.0,13.66,52.67,13.08,44.35,0.00595576,-0.11866551000000002,43.1,1.8120598891732735,13.660811745875042,3.247905917121901e-12,0.19532246966053018,3286.872584604314,7.199367204511308,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-580WT,G-Star Pte Ltd,Mono-c-Si,0,580.0,551.8,2.56,,,72.0,13.66,52.67,13.08,44.35,0.00595576,-0.11866551000000002,43.1,1.8120598891732735,13.660811745875042,3.247905917121901e-12,0.19532246966053018,3286.872584604314,7.199367204511308,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-585BT,G-Star Pte Ltd,Mono-c-Si,0,585.0,551.6,2.77,,,78.0,13.86,53.73,12.97,45.11,0.00613998,-0.15904079999999998,43.2,1.983931779348003,13.877193670892906,2.3392947428306642e-11,0.18539514449111374,149.44898782464537,-4.30728116101602,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G78M-585WT,G-Star Pte Ltd,Mono-c-Si,0,585.0,551.6,2.77,,,78.0,13.86,53.73,12.97,45.11,0.00613998,-0.15904079999999998,43.2,1.983931779348003,13.877193670892906,2.3392947428306642e-11,0.18539514449111374,149.44898782464537,-4.30728116101602,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-585BT,G-Star Pte Ltd,Mono-c-Si,0,585.0,556.7,2.56,,,72.0,13.72,52.85,13.13,44.56,0.005981920000000001,-0.11907105,43.1,1.8197913020594683,13.72134402460164,3.3407478768999913e-12,0.19005451249909905,1940.1043610166323,7.413963736651416,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-585WT,G-Star Pte Ltd,Mono-c-Si,0,585.0,556.7,2.56,,,72.0,13.72,52.85,13.13,44.56,0.005981920000000001,-0.11907105,43.1,1.8197913020594683,13.72134402460164,3.3407478768999913e-12,0.19005451249909905,1940.1043610166323,7.413963736651416,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-590BT,G-Star Pte Ltd,Mono-c-Si,0,590.0,556.4,2.77,,,78.0,13.93,53.87,13.04,45.25,0.00617099,-0.1594552,43.2,1.9892702809620204,13.946847755587106,2.3573776093121668e-11,0.18300921711488216,151.31501596193365,-4.287763835714908,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-590WT,G-Star Pte Ltd,Mono-c-Si,0,590.0,556.4,2.77,,,78.0,13.93,53.87,13.04,45.25,0.00617099,-0.1594552,43.2,1.9892702809620204,13.946847755587106,2.3573776093121668e-11,0.18300921711488216,151.31501596193365,-4.287763835714908,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-590BT,G-Star Pte Ltd,Mono-c-Si,0,590.0,561.5,2.56,,,72.0,13.78,53.03,13.18,44.77,0.00600808,-0.11947659,43.1,1.8275243421586345,13.781845144940778,3.4355754130660884e-12,0.18482646873315317,1380.3299268155947,7.627332385428862,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-590WT,G-Star Pte Ltd,Mono-c-Si,0,590.0,561.5,2.56,,,72.0,13.78,53.03,13.18,44.77,0.00600808,-0.11947659,43.1,1.8275243421586345,13.781845144940778,3.4355754130660884e-12,0.18482646873315317,1380.3299268155947,7.627332385428862,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J60M-590BT,G-Star Pte Ltd,Mono-c-Si,0,590.0,555.4,2.81,,,60.0,18.3,41.2,17.21,34.3,0.008655900000000001,-0.11906800000000001,43.4,1.521323289505899,18.31944563012725,3.1129604089420335e-11,0.12606443608253684,118.63740996564377,-1.978189087919185,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J60M-590WT,G-Star Pte Ltd,Mono-c-Si,0,590.0,555.4,2.81,,,60.0,18.3,41.2,17.21,34.3,0.008655900000000001,-0.11906800000000001,43.4,1.521323289505899,18.31944563012725,3.1129604089420335e-11,0.12606443608253684,118.63740996564377,-1.978189087919185,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD7G78M-595BT,G-Star Pte Ltd,Mono-c-Si,0,595.0,561.2,2.77,,,78.0,14.0,54.01,13.11,45.39,0.006202,-0.1598696,43.2,1.9946101122848314,14.016506726479362,2.3755446110754768e-11,0.18064848303796216,153.21504084702747,-4.268217685333822,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-595WT,G-Star Pte Ltd,Mono-c-Si,0,595.0,561.2,2.77,,,78.0,14.0,54.01,13.11,45.39,0.006202,-0.1598696,43.2,1.9946101122848314,14.016506726479362,2.3755446110754768e-11,0.18064848303796216,153.21504084702747,-4.268217685333822,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-595BT,G-Star Pte Ltd,Mono-c-Si,0,595.0,566.4,2.56,,,72.0,13.84,53.21,13.23,44.98,0.00603424,-0.11988213,43.1,1.8352590009390504,13.842315540075504,3.5324151275237503e-12,0.17963788104597547,1073.6970635949738,7.839484158982689,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-595WT,G-Star Pte Ltd,Mono-c-Si,0,595.0,566.4,2.56,,,72.0,13.84,53.21,13.23,44.98,0.00603424,-0.11988213,43.1,1.8352590009390504,13.842315540075504,3.5324151275237503e-12,0.17963788104597547,1073.6970635949738,7.839484158982689,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J60M-595BT,G-Star Pte Ltd,Mono-c-Si,0,595.0,560.3,2.81,,,60.0,18.34,41.4,17.25,34.5,0.008674820000000001,-0.11964599999999999,43.4,1.5293749630225615,18.359051682756757,3.157028993168209e-11,0.1241729946720419,119.53446655438476,-1.8839230542641052,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J60M-595WT,G-Star Pte Ltd,Mono-c-Si,0,595.0,560.3,2.81,,,60.0,18.34,41.4,17.25,34.5,0.008674820000000001,-0.11964599999999999,43.4,1.5293749630225615,18.359051682756757,3.157028993168209e-11,0.1241729946720419,119.53446655438476,-1.8839230542641052,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD7G78M-600BT,G-Star Pte Ltd,Mono-c-Si,0,600.0,566.1,2.77,,,78.0,14.07,54.15,13.18,45.53,0.006233010000000001,-0.16028399999999998,43.2,1.9999512767265324,14.086170538390629,2.3937962461348558e-11,0.17831254233209323,155.1499040609602,-4.248642515898451,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G78M-600WT,G-Star Pte Ltd,Mono-c-Si,0,600.0,566.1,2.77,,,78.0,14.07,54.15,13.18,45.53,0.006233010000000001,-0.16028399999999998,43.2,1.9999512767265324,14.086170538390629,2.3937962461348558e-11,0.17831254233209323,155.1499040609602,-4.248642515898451,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-600BT,G-Star Pte Ltd,Mono-c-Si,0,600.0,571.3,2.56,,,72.0,13.9,53.39,13.28,45.19,0.0060604000000000005,-0.12028767000000001,43.1,1.8429952114811514,13.902755600530067,3.631290561150355e-12,0.17448830809302585,880.1665820399216,8.050422585657042,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-600WT,G-Star Pte Ltd,Mono-c-Si,0,600.0,571.3,2.56,,,72.0,13.9,53.39,13.28,45.19,0.0060604000000000005,-0.12028767000000001,43.1,1.8429952114811514,13.902755600530067,3.631290561150355e-12,0.17448830809302585,880.1665820399216,8.050422585657042,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J60M-600BT,G-Star Pte Ltd,Mono-c-Si,0,600.0,565.1,2.81,,,60.0,18.39,41.6,17.3,34.7,0.008698470000000002,-0.120224,43.4,1.5373992940690073,18.408631322200474,3.2016418472077976e-11,0.12222628382135807,120.64314865963286,-1.7942034578908765,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J60M-600WT,G-Star Pte Ltd,Mono-c-Si,0,600.0,565.1,2.81,,,60.0,18.39,41.6,17.3,34.7,0.008698470000000002,-0.120224,43.4,1.5373992940690073,18.408631322200474,3.2016418472077976e-11,0.12222628382135807,120.64314865963286,-1.7942034578908765,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD7G78M-605BT,G-Star Pte Ltd,Mono-c-Si,0,605.0,570.9,2.77,,,78.0,14.14,54.29,13.25,45.67,0.0062640199999999995,-0.16069840000000002,43.2,2.0052937464443006,14.155839133238777,2.4121320417048237e-11,0.17600100876594113,157.12060980574628,-4.2290419362394704,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7G78M-605WT,G-Star Pte Ltd,Mono-c-Si,0,605.0,570.9,2.77,,,78.0,14.14,54.29,13.25,45.67,0.0062640199999999995,-0.16069840000000002,43.2,2.0052937464443006,14.155839133238777,2.4121320417048237e-11,0.17600100876594113,157.12060980574628,-4.2290419362394704,-0.3321,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S72T-605BT,G-Star Pte Ltd,Mono-c-Si,0,605.0,576.1,2.56,,,72.0,13.96,53.57,13.33,45.4,0.00608656,-0.12069321000000001,43.1,1.850733020161562,13.963165775215499,3.732231298927783e-12,0.1693772978308632,746.8967493262816,8.260165915699774,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-605WT,G-Star Pte Ltd,Mono-c-Si,0,605.0,576.1,2.56,,,72.0,13.96,53.57,13.33,45.4,0.00608656,-0.12069321000000001,43.1,1.850733020161562,13.963165775215499,3.732231298927783e-12,0.1693772978308632,746.8967493262816,8.260165915699774,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J60M-605BT,G-Star Pte Ltd,Mono-c-Si,0,605.0,569.9,2.81,,,60.0,18.43,41.8,17.34,34.9,0.00871739,-0.12080199999999999,43.4,1.5454484935219774,18.448247379790452,3.246005856850727e-11,0.12035456591473025,121.55907795589894,-1.7020527510673127,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J60M-605WT,G-Star Pte Ltd,Mono-c-Si,0,605.0,569.9,2.81,,,60.0,18.43,41.8,17.34,34.9,0.00871739,-0.12080199999999999,43.4,1.5454484935219774,18.448247379790452,3.246005856850727e-11,0.12035456591473025,121.55907795589894,-1.7020527510673127,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8R66T-605BT,G-Star Pte Ltd,Mono-c-Si,0,605.0,575.6,2.68,,,66.0,15.71,48.32,14.94,40.5,0.006551070000000001,-0.1142768,43.1,1.6641866949095347,15.717925027237724,3.824518238766244e-12,0.16958974601745017,336.1824299975009,2.347285188974779,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-605WT,G-Star Pte Ltd,Mono-c-Si,0,605.0,575.6,2.68,,,66.0,15.71,48.32,14.94,40.5,0.006551070000000001,-0.1142768,43.1,1.6641866949095347,15.717925027237724,3.824518238766244e-12,0.16958974601745017,336.1824299975009,2.347285188974779,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-610BT,G-Star Pte Ltd,Mono-c-Si,0,610.0,575.8,2.77,,,78.0,14.21,54.43,13.32,45.81,0.00629503,-0.1611128,43.2,2.010637521838104,14.225512466449949,2.430552391719413e-11,0.1737134993170519,159.12806764786478,-4.209415927357585,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7G78M-610WT,G-Star Pte Ltd,Mono-c-Si,0,610.0,575.8,2.77,,,78.0,14.21,54.43,13.32,45.81,0.00629503,-0.1611128,43.2,2.010637521838104,14.225512466449949,2.430552391719413e-11,0.1737134993170519,159.12806764786478,-4.209415927357585,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-610BT,G-Star Pte Ltd,Mono-c-Si,0,610.0,581.0,2.56,,,72.0,14.02,53.75,13.38,45.6,0.0061127199999999994,-0.12109874999999999,43.1,1.8582856394682647,14.023553647771726,3.824203998964507e-12,0.165150572770199,651.5589582545905,8.442772889906227,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S72T-610WT,G-Star Pte Ltd,Mono-c-Si,0,610.0,581.0,2.56,,,72.0,14.02,53.75,13.38,45.6,0.0061127199999999994,-0.12109874999999999,43.1,1.8582856394682647,14.023553647771726,3.824203998964507e-12,0.165150572770199,651.5589582545905,8.442772889906227,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-610BT,G-Star Pte Ltd,Mono-c-Si,0,610.0,580.0,2.77,,,78.0,13.61,56.02,12.97,47.04,0.00593396,-0.12621306000000002,43.1,1.9288908343611395,13.61491024065587,3.2963183769240073e-12,0.2195950492855409,608.6643895610039,7.385742881928506,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-610WT,G-Star Pte Ltd,Mono-c-Si,0,610.0,580.0,2.77,,,78.0,13.61,56.02,12.97,47.04,0.00593396,-0.12621306000000002,43.1,1.9288908343611395,13.61491024065587,3.2963183769240073e-12,0.2195950492855409,608.6643895610039,7.385742881928506,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J60M-610BT,G-Star Pte Ltd,Mono-c-Si,0,610.0,574.7,2.81,,,60.0,18.48,42.0,17.38,35.1,0.008741040000000002,-0.12137999999999999,43.4,1.5539145159206726,18.498506868240163,3.314213757255122e-11,0.11839406149204088,118.22217784742725,-1.5558581831545808,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J60M-610WT,G-Star Pte Ltd,Mono-c-Si,0,610.0,574.7,2.81,,,60.0,18.48,42.0,17.38,35.1,0.008741040000000002,-0.12137999999999999,43.4,1.5539145159206726,18.498506868240163,3.314213757255122e-11,0.11839406149204088,118.22217784742725,-1.5558581831545808,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8R66T-610BT,G-Star Pte Ltd,Mono-c-Si,0,610.0,580.4,2.68,,,66.0,15.75,48.54,14.98,40.73,0.00656775,-0.1147971,43.1,1.6725392734266207,15.757728174927843,3.886431735580195e-12,0.16647934105281187,339.28445604144474,2.461502886496269,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8R66T-610WT,G-Star Pte Ltd,Mono-c-Si,0,610.0,580.4,2.68,,,66.0,15.75,48.54,14.98,40.73,0.00656775,-0.1147971,43.1,1.6725392734266207,15.757728174927843,3.886431735580195e-12,0.16647934105281187,339.28445604144474,2.461502886496269,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD7S78T-615BT,G-Star Pte Ltd,Mono-c-Si,0,615.0,584.8,2.77,,,78.0,13.65,56.24,13.01,47.28,0.005951400000000001,-0.12670872,43.1,1.9373822697849434,13.65476325306492,3.351947928165459e-12,0.2150039547311812,616.1343831922126,7.508136317448374,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-615WT,G-Star Pte Ltd,Mono-c-Si,0,615.0,584.8,2.77,,,78.0,13.65,56.24,13.01,47.28,0.005951400000000001,-0.12670872,43.1,1.9373822697849434,13.65476325306492,3.351947928165459e-12,0.2150039547311812,616.1343831922126,7.508136317448374,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-615BT,G-Star Pte Ltd,Mono-c-Si,0,615.0,585.3,2.68,,,66.0,15.79,48.76,15.02,40.95,0.00658443,-0.11531739999999999,43.1,1.6806994357743887,15.797551440818312,3.935789076469444e-12,0.16414179187841801,343.21912327283246,2.5466410582567267,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-615WT,G-Star Pte Ltd,Mono-c-Si,0,615.0,585.3,2.68,,,66.0,15.79,48.76,15.02,40.95,0.00658443,-0.11531739999999999,43.1,1.6806994357743887,15.797551440818312,3.935789076469444e-12,0.16414179187841801,343.21912327283246,2.5466410582567267,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-620BT,G-Star Pte Ltd,Mono-c-Si,0,620.0,589.7,2.77,,,78.0,13.69,56.46,13.05,47.51,0.0059688399999999996,-0.12720438,43.1,1.9456845785380428,13.69462492571465,3.398544411067888e-12,0.2113106555236334,625.4895887557437,7.604567005718416,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-620WT,G-Star Pte Ltd,Mono-c-Si,0,620.0,589.7,2.77,,,78.0,13.69,56.46,13.05,47.51,0.0059688399999999996,-0.12720438,43.1,1.9456845785380428,13.69462492571465,3.398544411067888e-12,0.2113106555236334,625.4895887557437,7.604567005718416,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-620BT,G-Star Pte Ltd,Mono-c-Si,0,620.0,590.1,2.68,,,66.0,15.83,48.98,15.06,41.17,0.00660111,-0.11583769999999999,43.1,1.6888586768936222,15.83737723919484,3.98529990752916e-12,0.16181716906661936,347.2255301463925,2.6308845989514373,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-620WT,G-Star Pte Ltd,Mono-c-Si,0,620.0,590.1,2.68,,,66.0,15.83,48.98,15.06,41.17,0.00660111,-0.11583769999999999,43.1,1.6888586768936222,15.83737723919484,3.98529990752916e-12,0.16181716906661936,347.2255301463925,2.6308845989514373,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-625BT,G-Star Pte Ltd,Mono-c-Si,0,625.0,594.6,2.77,,,78.0,13.73,56.68,13.09,47.75,0.00598628,-0.12770004,43.1,1.9541735708387555,13.734482600777367,3.4549400661005595e-12,0.20677480126479253,633.3417073117828,7.72484661855149,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-625WT,G-Star Pte Ltd,Mono-c-Si,0,625.0,594.6,2.77,,,78.0,13.73,56.68,13.09,47.75,0.00598628,-0.12770004,43.1,1.9541735708387555,13.734482600777367,3.4549400661005595e-12,0.20677480126479253,633.3417073117828,7.72484661855149,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-625BT,G-Star Pte Ltd,Mono-c-Si,0,625.0,595.0,2.68,,,66.0,15.87,49.2,15.1,41.4,0.00661779,-0.116358,43.1,1.697207998636051,15.877187923924284,4.048061048244866e-12,0.15875402394515783,350.50821213813583,2.7418447472813083,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-625WT,G-Star Pte Ltd,Mono-c-Si,0,625.0,595.0,2.68,,,66.0,15.87,49.2,15.1,41.4,0.00661779,-0.116358,43.1,1.697207998636051,15.877187923924284,4.048061048244866e-12,0.15875402394515783,350.50821213813583,2.7418447472813083,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-630BT,G-Star Pte Ltd,Mono-c-Si,0,630.0,599.4,2.77,,,78.0,13.77,56.9,13.13,47.99,0.00600372,-0.1281957,43.1,1.962661285142123,13.774342540763694,3.5117671014780785e-12,0.2022675693652644,641.3812996045351,7.844032657263522,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-630WT,G-Star Pte Ltd,Mono-c-Si,0,630.0,599.4,2.77,,,78.0,13.77,56.9,13.13,47.99,0.00600372,-0.1281957,43.1,1.962661285142123,13.774342540763694,3.5117671014780785e-12,0.2022675693652644,641.3812996045351,7.844032657263522,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-630BT,G-Star Pte Ltd,Mono-c-Si,0,630.0,599.9,2.68,,,66.0,15.91,49.42,15.14,41.62,0.00663447,-0.1168783,43.1,1.7053653083236795,15.917018786289436,4.097957090822697e-12,0.1564570094035296,354.6526308201078,2.82419934365208,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-630WT,G-Star Pte Ltd,Mono-c-Si,0,630.0,599.9,2.68,,,66.0,15.91,49.42,15.14,41.62,0.00663447,-0.1168783,43.1,1.7053653083236795,15.917018786289436,4.097957090822697e-12,0.1564570094035296,354.6526308201078,2.82419934365208,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-635BT,G-Star Pte Ltd,Mono-c-Si,0,635.0,604.3,2.77,,,78.0,13.81,57.12,13.17,48.22,0.00602116,-0.12869136,43.1,1.970960376191323,13.814211385241641,3.5592700831141528e-12,0.19864897355157274,651.4109437671551,7.9376444348577335,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-635WT,G-Star Pte Ltd,Mono-c-Si,0,635.0,604.3,2.77,,,78.0,13.81,57.12,13.17,48.22,0.00602116,-0.12869136,43.1,1.970960376191323,13.814211385241641,3.5592700831141528e-12,0.19864897355157274,651.4109437671551,7.9376444348577335,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-635BT,G-Star Pte Ltd,Mono-c-Si,0,635.0,604.8,2.68,,,66.0,15.95,49.64,15.18,41.84,0.006651150000000001,-0.11739859999999999,43.1,1.7135217239626424,15.956852138032552,4.1479984170504676e-12,0.15417258442650547,358.8737866720754,2.905699574598123,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-635WT,G-Star Pte Ltd,Mono-c-Si,0,635.0,604.8,2.68,,,66.0,15.95,49.64,15.18,41.84,0.006651150000000001,-0.11739859999999999,43.1,1.7135217239626424,15.956852138032552,4.1479984170504676e-12,0.15417258442650547,358.8737866720754,2.905699574598123,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-640BT,G-Star Pte Ltd,Mono-c-Si,0,640.0,609.1,2.77,,,78.0,13.85,57.34,13.21,48.48,0.006038600000000001,-0.12918702,43.1,1.9798201749813704,13.854062382256915,3.636589461771947e-12,0.19248035396827032,656.2289904221738,8.103566426897297,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-640WT,G-Star Pte Ltd,Mono-c-Si,0,640.0,609.1,2.77,,,78.0,13.85,57.34,13.21,48.48,0.006038600000000001,-0.12918702,43.1,1.9798201749813704,13.854062382256915,3.636589461771947e-12,0.19248035396827032,656.2289904221738,8.103566426897297,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-640BT,G-Star Pte Ltd,Mono-c-Si,0,640.0,609.6,2.68,,,66.0,15.99,49.86,15.22,42.06,0.0066678300000000005,-0.1179189,43.1,1.721677257573623,15.996687964762001,4.198182773354137e-12,0.15190064292457384,363.1734567268184,2.986358408196743,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-640WT,G-Star Pte Ltd,Mono-c-Si,0,640.0,609.6,2.68,,,66.0,15.99,49.86,15.22,42.06,0.0066678300000000005,-0.1179189,43.1,1.721677257573623,15.996687964762001,4.198182773354137e-12,0.15190064292457384,363.1734567268184,2.986358408196743,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-645BT,G-Star Pte Ltd,Mono-c-Si,0,645.0,614.0,2.77,,,78.0,13.89,57.56,13.25,48.68,0.0060560399999999995,-0.12968268,43.1,1.987555632230107,13.893956120096325,3.655007192022819e-12,0.1914793679064498,672.2871108240535,8.122350389519472,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-645WT,G-Star Pte Ltd,Mono-c-Si,0,645.0,614.0,2.77,,,78.0,13.89,57.56,13.25,48.68,0.0060560399999999995,-0.12968268,43.1,1.987555632230107,13.893956120096325,3.655007192022819e-12,0.1914793679064498,672.2871108240535,8.122350389519472,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-645BT,G-Star Pte Ltd,Mono-c-Si,0,645.0,614.5,2.68,,,66.0,16.03,50.08,15.26,42.27,0.006684510000000001,-0.1184392,43.1,1.7296413821023005,16.036543666988237,4.2350675841420905e-12,0.15038416030043425,368.3955942620517,3.0391382491093992,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-645WT,G-Star Pte Ltd,Mono-c-Si,0,645.0,614.5,2.68,,,66.0,16.03,50.08,15.26,42.27,0.006684510000000001,-0.1184392,43.1,1.7296413821023005,16.036543666988237,4.2350675841420905e-12,0.15038416030043425,368.3955942620517,3.0391382491093992,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-650BT,G-Star Pte Ltd,Mono-c-Si,0,650.0,618.9,2.77,,,78.0,13.93,57.78,13.29,48.91,0.00607348,-0.13017834,43.1,1.9958518371403722,13.933831989669647,3.7032384918721615e-12,0.18792793013392856,683.1532374311589,8.213468774609018,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-650WT,G-Star Pte Ltd,Mono-c-Si,0,650.0,618.9,2.77,,,78.0,13.93,57.78,13.29,48.91,0.00607348,-0.13017834,43.1,1.9958518371403722,13.933831989669647,3.7032384918721615e-12,0.18792793013392856,683.1532374311589,8.213468774609018,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J66M-650BT,G-Star Pte Ltd,Mono-c-Si,0,650.0,612.0,3.08,,,66.0,18.21,45.4,17.29,37.6,0.00861333,-0.131206,43.4,1.6641341271918764,18.217541581406703,2.5666601209926057e-11,0.15317809474902516,369.8658141318624,-3.5016637653759344,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-650WT,G-Star Pte Ltd,Mono-c-Si,0,650.0,612.0,3.08,,,66.0,18.21,45.4,17.29,37.6,0.00861333,-0.131206,43.4,1.6641341271918764,18.217541581406703,2.5666601209926057e-11,0.15317809474902516,369.8658141318624,-3.5016637653759344,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8R66T-650BT,G-Star Pte Ltd,Mono-c-Si,0,650.0,619.4,2.68,,,66.0,16.07,50.3,15.3,42.49,0.006701190000000001,-0.1189595,43.1,1.737795208232797,16.07638427599289,4.285441341586836e-12,0.14813484974703506,372.8734386448964,3.1182733981819912,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8R66T-650WT,G-Star Pte Ltd,Mono-c-Si,0,650.0,619.4,2.68,,,66.0,16.07,50.3,15.3,42.49,0.006701190000000001,-0.1189595,43.1,1.737795208232797,16.07638427599289,4.285441341586836e-12,0.14813484974703506,372.8734386448964,3.1182733981819912,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-655BT,G-Star Pte Ltd,Mono-c-Si,0,655.0,623.8,2.77,,,78.0,13.97,58.0,13.33,49.14,0.0060909200000000005,-0.13067399999999998,43.1,2.0041471063351604,13.973710172351021,3.751709098682226e-12,0.1843984570913052,694.3199051817036,8.303778209709444,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD7S78T-655WT,G-Star Pte Ltd,Mono-c-Si,0,655.0,623.8,2.77,,,78.0,13.97,58.0,13.33,49.14,0.0060909200000000005,-0.13067399999999998,43.1,2.0041471063351604,13.973710172351021,3.751709098682226e-12,0.1843984570913052,694.3199051817036,8.303778209709444,-0.2928,N,2025.7.3,6/23/2025,4.0,first_pass +G-Star Pte Ltd GSD8J66M-655BT,G-Star Pte Ltd,Mono-c-Si,0,655.0,616.8,3.08,,,66.0,18.26,45.6,17.33,37.8,0.00863698,-0.13178399999999998,43.4,1.6725901034660304,18.268135463435552,2.619814600246047e-11,0.1511376011255926,339.22746452038075,-3.3604112041336727,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-655WT,G-Star Pte Ltd,Mono-c-Si,0,655.0,616.8,3.08,,,66.0,18.26,45.6,17.33,37.8,0.00863698,-0.13178399999999998,43.4,1.6725901034660304,18.268135463435552,2.619814600246047e-11,0.1511376011255926,339.22746452038075,-3.3604112041336727,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-660BT,G-Star Pte Ltd,Mono-c-Si,0,660.0,621.7,3.08,,,66.0,18.31,45.8,17.37,38.0,0.008660629999999999,-0.13236199999999998,43.4,1.681048796974456,18.31870682946934,2.6736835149899675e-11,0.1491060297019925,313.56206617722523,-3.2200672841853097,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-660WT,G-Star Pte Ltd,Mono-c-Si,0,660.0,621.7,3.08,,,66.0,18.31,45.8,17.37,38.0,0.008660629999999999,-0.13236199999999998,43.4,1.681048796974456,18.31870682946934,2.6736835149899675e-11,0.1491060297019925,313.56206617722523,-3.2200672841853097,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-665BT,G-Star Pte Ltd,Mono-c-Si,0,665.0,626.5,3.08,,,66.0,18.36,46.0,17.41,38.2,0.008684279999999999,-0.13294,43.4,1.6895101645339883,18.36925604767243,2.7282697470959635e-11,0.14708331210301892,291.7497550978821,-3.0805977490592586,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-665WT,G-Star Pte Ltd,Mono-c-Si,0,665.0,626.5,3.08,,,66.0,18.36,46.0,17.41,38.2,0.008684279999999999,-0.13294,43.4,1.6895101645339883,18.36925604767243,2.7282697470959635e-11,0.14708331210301892,291.7497550978821,-3.0805977490592586,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-670BT,G-Star Pte Ltd,Mono-c-Si,0,670.0,631.3,3.08,,,66.0,18.41,46.2,17.45,38.4,0.008707930000000001,-0.133518,43.4,1.6979742331535714,18.419783477237015,2.783578462654851e-11,0.14506939857842213,272.98347940739814,-2.9420314773812244,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-670WT,G-Star Pte Ltd,Mono-c-Si,0,670.0,631.3,3.08,,,66.0,18.41,46.2,17.45,38.4,0.008707930000000001,-0.133518,43.4,1.6979742331535714,18.419783477237015,2.783578462654851e-11,0.14506939857842213,272.98347940739814,-2.9420314773812244,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-675BT,G-Star Pte Ltd,Mono-c-Si,0,675.0,636.1,3.08,,,66.0,18.46,46.4,17.49,38.6,0.008731580000000001,-0.134096,43.4,1.706440936793266,18.470289471459015,2.8396117075015844e-11,0.1430642144359834,256.6667720802422,-2.80431216966355,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8J66M-675WT,G-Star Pte Ltd,Mono-c-Si,0,675.0,636.1,3.08,,,66.0,18.46,46.4,17.49,38.6,0.008731580000000001,-0.134096,43.4,1.706440936793266,18.470289471459015,2.8396117075015844e-11,0.1430642144359834,256.6667720802422,-2.80431216966355,-0.3361,N,2025.7.3,6/23/2025,4.0,bootstrapping +G-Star Pte Ltd GSD8K66T-700BT,G-Star Pte Ltd,Mono-c-Si,0,700.0,666.3,3.08,,,66.0,18.1,48.6,17.44,40.14,0.007511500000000002,-0.11425860000000002,43.1,1.6571474689521655,18.10000362675538,3.318210088337899e-12,0.17043367460390618,850585.2836791782,0.5386264255339309,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-700WT,G-Star Pte Ltd,Mono-c-Si,0,700.0,666.3,3.08,,,66.0,18.1,48.6,17.44,40.14,0.007511500000000002,-0.11425860000000002,43.1,1.6571474689521655,18.10000362675538,3.318210088337899e-12,0.17043367460390618,850585.2836791782,0.5386264255339309,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)700BT,G-Star Pte Ltd,Mono-c-Si,0,700.0,665.9,3.08,,,22.0,18.1,48.6,17.44,40.14,0.007819200000000002,-0.11819520000000001,43.2,1.6672541598177553,18.10028053121933,3.96299197554484e-12,0.18545435817440323,11965.599151746881,-1.41320970528572,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSN8K66T(H)700WT,G-Star Pte Ltd,Mono-c-Si,0,700.0,665.9,3.08,,,22.0,18.1,48.6,17.44,40.14,0.007819200000000002,-0.11819520000000001,43.2,1.6672541598177553,18.10028053121933,3.96299197554484e-12,0.18545435817440323,11965.599151746881,-1.41320970528572,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8K66T-705BT,G-Star Pte Ltd,Mono-c-Si,0,705.0,671.1,3.08,,,66.0,18.14,48.79,17.48,40.34,0.0075281,-0.11470529,43.1,1.6642692829539918,18.140282020534492,3.362752756682607e-12,0.18428236435148956,11853.329319000446,0.6323290781527042,-0.2905,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8K66T-705WT,G-Star Pte Ltd,Mono-c-Si,0,705.0,671.1,3.08,,,66.0,18.14,48.79,17.48,40.34,0.0075281,-0.11470529,43.1,1.6642692829539918,18.140282020534492,3.362752756682607e-12,0.18428236435148956,11853.329319000446,0.6323290781527042,-0.2905,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSN8K66T(H)705BT,G-Star Pte Ltd,Mono-c-Si,0,705.0,670.7,3.08,,,22.0,18.14,48.79,17.48,40.34,0.00783648,-0.11865728,43.2,1.6745460549292341,18.140282073962513,4.025596178073036e-12,0.18296563679653147,11766.406379608066,-1.3032082683830435,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSN8K66T(H)705WT,G-Star Pte Ltd,Mono-c-Si,0,705.0,670.7,3.08,,,22.0,18.14,48.79,17.48,40.34,0.00783648,-0.11865728,43.2,1.6745460549292341,18.140282073962513,4.025596178073036e-12,0.18296563679653147,11766.406379608066,-1.3032082683830435,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8K66T-710BT,G-Star Pte Ltd,Mono-c-Si,0,710.0,676.0,3.08,,,66.0,18.18,48.98,17.52,40.53,0.0075447,-0.11515197999999999,43.1,1.6714526137982135,18.180003540419523,3.412647040314857e-12,0.16596002154068015,852206.3137649568,0.7361340763716862,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-710WT,G-Star Pte Ltd,Mono-c-Si,0,710.0,676.0,3.08,,,66.0,18.18,48.98,17.52,40.53,0.0075447,-0.11515197999999999,43.1,1.6714526137982135,18.180003540419523,3.412647040314857e-12,0.16596002154068015,852206.3137649568,0.7361340763716862,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)710BT,G-Star Pte Ltd,Mono-c-Si,0,710.0,675.6,3.08,,,22.0,18.18,48.98,17.52,40.53,0.00785376,-0.11911936,43.2,1.6816709448624751,18.180284022787053,4.07688547930083e-12,0.18113462856618356,11594.23786847557,-1.2177102247995626,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSN8K66T(H)710WT,G-Star Pte Ltd,Mono-c-Si,0,710.0,675.6,3.08,,,22.0,18.18,48.98,17.52,40.53,0.00785376,-0.11911936,43.2,1.6816709448624751,18.180284022787053,4.07688547930083e-12,0.18113462856618356,11594.23786847557,-1.2177102247995626,-0.2925,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8K66T-715BT,G-Star Pte Ltd,Mono-c-Si,0,715.0,680.9,3.08,,,66.0,18.22,49.17,17.56,40.72,0.007561300000000001,-0.11559867000000001,43.1,1.67841588375057,18.220285940681922,3.4481628889256314e-12,0.18063769600406435,11510.145923292219,0.8051706924561337,-0.2905,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSD8K66T-715WT,G-Star Pte Ltd,Mono-c-Si,0,715.0,680.9,3.08,,,66.0,18.22,49.17,17.56,40.72,0.007561300000000001,-0.11559867000000001,43.1,1.67841588375057,18.220285940681922,3.4481628889256314e-12,0.18063769600406435,11510.145923292219,0.8051706924561337,-0.2905,N,2025.7.3,6/23/2025,2.0,first_pass +G-Star Pte Ltd GSN8K66T(H)715BT,G-Star Pte Ltd,Mono-c-Si,0,715.0,680.4,3.08,,,22.0,18.22,49.17,17.56,40.72,0.007871040000000001,-0.11958144000000001,43.2,1.6890119621671926,18.22003456618671,4.144644202660426e-12,0.1619949424495576,85388.34652717304,-1.1015520714911902,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)715WT,G-Star Pte Ltd,Mono-c-Si,0,715.0,680.4,3.08,,,22.0,18.22,49.17,17.56,40.72,0.007871040000000001,-0.11958144000000001,43.2,1.6890119621671926,18.22003456618671,4.144644202660426e-12,0.1619949424495576,85388.34652717304,-1.1015520714911902,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-720BT,G-Star Pte Ltd,Mono-c-Si,0,720.0,685.7,3.08,,,66.0,18.26,49.36,17.6,40.91,0.007577900000000001,-0.11604536,43.1,1.6855959630711228,18.260003467652318,3.498448684542154e-12,0.16212042879279215,853699.5546709102,0.907079070576282,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-720WT,G-Star Pte Ltd,Mono-c-Si,0,720.0,685.7,3.08,,,66.0,18.26,49.36,17.6,40.91,0.007577900000000001,-0.11604536,43.1,1.6855959630711228,18.260003467652318,3.498448684542154e-12,0.16212042879279215,853699.5546709102,0.907079070576282,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)720BT,G-Star Pte Ltd,Mono-c-Si,0,720.0,685.3,3.08,,,22.0,18.26,49.36,17.6,40.91,0.00788832,-0.12004352,43.2,1.6961031580461323,18.260003428248478,4.194304496713737e-12,0.1601382060380015,852954.518708267,-1.022088423904877,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)720WT,G-Star Pte Ltd,Mono-c-Si,0,720.0,685.3,3.08,,,22.0,18.26,49.36,17.6,40.91,0.00788832,-0.12004352,43.2,1.6961031580461323,18.260003428248478,4.194304496713737e-12,0.1601382060380015,852954.518708267,-1.022088423904877,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-725BT,G-Star Pte Ltd,Mono-c-Si,0,725.0,690.6,3.08,,,66.0,18.3,49.55,17.64,41.1,0.007594500000000001,-0.11649205,43.1,1.692667888920027,18.300003431360317,3.5416912655590972e-12,0.16021169600340848,854438.9814489979,0.9916052592876522,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-725WT,G-Star Pte Ltd,Mono-c-Si,0,725.0,690.6,3.08,,,66.0,18.3,49.55,17.64,41.1,0.007594500000000001,-0.11649205,43.1,1.692667888920027,18.300003431360317,3.5416912655590972e-12,0.16021169600340848,854438.9814489979,0.9916052592876522,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)725BT,G-Star Pte Ltd,Mono-c-Si,0,725.0,690.2,3.08,,,22.0,18.3,49.55,17.64,41.1,0.007905600000000002,-0.1205056,43.2,1.7032273127805675,18.300003391740205,4.246473424583752e-12,0.15822282717675837,853689.7528249281,-0.9387339238330261,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)725WT,G-Star Pte Ltd,Mono-c-Si,0,725.0,690.2,3.08,,,22.0,18.3,49.55,17.64,41.1,0.007905600000000002,-0.1205056,43.2,1.7032273127805675,18.300003391740205,4.246473424583752e-12,0.15822282717675837,853689.7528249281,-0.9387339238330261,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-730BT,G-Star Pte Ltd,Mono-c-Si,0,730.0,695.5,3.08,,,66.0,18.34,49.74,17.68,41.29,0.007611100000000001,-0.11693874,43.1,1.6997399805643971,18.340003395128228,3.585160229691719e-12,0.158310277419627,855173.6619180434,1.0755099677048119,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-730WT,G-Star Pte Ltd,Mono-c-Si,0,730.0,695.5,3.08,,,66.0,18.34,49.74,17.68,41.29,0.007611100000000001,-0.11693874,43.1,1.6997399805643971,18.340003395128228,3.585160229691719e-12,0.158310277419627,855173.6619180434,1.0755099677048119,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)730BT,G-Star Pte Ltd,Mono-c-Si,0,730.0,695.1,3.08,,,22.0,18.34,49.74,17.68,41.29,0.00792288,-0.12096768000000001,43.2,1.7103516344560972,18.34000335529142,4.298918551581987e-12,0.15631478231564291,854420.2606901054,-0.8559925869691563,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)730WT,G-Star Pte Ltd,Mono-c-Si,0,730.0,695.1,3.08,,,22.0,18.34,49.74,17.68,41.29,0.00792288,-0.12096768000000001,43.2,1.7103516344560972,18.34000335529142,4.298918551581987e-12,0.15631478231564291,854420.2606901054,-0.8559925869691563,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-735BT,G-Star Pte Ltd,Mono-c-Si,0,735.0,700.4,3.08,,,66.0,18.38,49.93,17.72,41.48,0.0076277,-0.11738543000000001,43.1,1.706812236772001,18.380003358955186,3.6288544879173276e-12,0.1564161273947195,855903.6331136791,1.1588001097784344,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-735WT,G-Star Pte Ltd,Mono-c-Si,0,735.0,700.4,3.08,,,66.0,18.38,49.93,17.72,41.48,0.0076277,-0.11738543000000001,43.1,1.706812236772001,18.380003358955186,3.6288544879173276e-12,0.1564161273947195,855903.6331136791,1.1588001097784344,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)735BT,G-Star Pte Ltd,Mono-c-Si,0,735.0,699.9,3.08,,,22.0,18.38,49.93,17.72,41.48,0.00794016,-0.12142976000000001,43.2,1.7174761218534065,18.380003318901267,4.351638564077026e-12,0.15441402570072413,855146.0762194062,-0.7738575866470032,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)735WT,G-Star Pte Ltd,Mono-c-Si,0,735.0,699.9,3.08,,,22.0,18.38,49.93,17.72,41.48,0.00794016,-0.12142976000000001,43.2,1.7174761218534065,18.380003318901267,4.351638564077026e-12,0.15441402570072413,855146.0762194062,-0.7738575866470032,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-740BT,G-Star Pte Ltd,Mono-c-Si,0,740.0,705.2,3.08,,,66.0,18.42,50.12,17.76,41.67,0.0076443000000000014,-0.11783212,43.1,1.7138844533023163,18.420003140165406,3.67276083737773e-12,0.1545296115478783,906464.6963552313,1.2414543492854773,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSD8K66T-740WT,G-Star Pte Ltd,Mono-c-Si,0,740.0,705.2,3.08,,,66.0,18.42,50.12,17.76,41.67,0.0076443000000000014,-0.11783212,43.1,1.7138844533023163,18.420003140165406,3.67276083737773e-12,0.1545296115478783,906464.6963552313,1.2414543492854773,-0.2905,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)740BT,G-Star Pte Ltd,Mono-c-Si,0,740.0,704.8,3.08,,,22.0,18.42,50.12,17.76,41.67,0.007957440000000001,-0.12189184,43.2,1.7246007737868205,18.4200032825689,4.404632152281514e-12,0.1525205119646508,855867.2382637889,-0.6923221950122773,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +G-Star Pte Ltd GSN8K66T(H)740WT,G-Star Pte Ltd,Mono-c-Si,0,740.0,704.8,3.08,,,22.0,18.42,50.12,17.76,41.67,0.007957440000000001,-0.12189184,43.2,1.7246007737868205,18.4200032825689,4.404632152281514e-12,0.1525205119646508,855867.2382637889,-0.6923221950122773,-0.2925,N,2025.7.3,6/23/2025,2.0,bootstrapping +Guangdong Golden Glass Technologies GG160M2-24/1324x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,160.0,143.4,1.3134080000000001,1.324,0.992,48.0,7.6,28.6,6.87,23.3,0.003116,-0.08665800000000001,46.7,1.1829689793673288,7.631230238942418,2.2692711163629646e-10,0.255442508568065,62.16292892671894,17.97417486606757,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG165M2-24/1324x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,165.0,148.0,1.3134080000000001,1.324,0.992,48.0,7.7,28.8,7.02,23.5,0.003157,-0.08726400000000001,46.7,1.1866430088931108,7.72568178888701,2.114774826722773e-10,0.24860869608878874,74.53869477922909,17.150066824681396,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG170M2-24/1324x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,170.0,152.6,1.3134080000000001,1.324,0.992,48.0,7.82,29.0,7.15,23.8,0.0032062,-0.08786999999999999,46.7,1.196941925229765,7.8422174290278805,2.245623589786557e-10,0.22427001945949904,78.93764886005883,17.562688080036548,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG175M2-24/1324x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,175.0,157.2,1.3134080000000001,1.324,0.992,48.0,7.96,29.2,7.29,24.0,0.0032636,-0.08847599999999999,46.7,1.2051294265098393,7.981145053874646,2.2868862804966718e-10,0.21627196020582215,81.41501423975775,17.5611423704549,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG175S1-36/1589x807,Guangdong Golden Glass Technologies,Mono-c-Si,0,175.0,158.7,1.282323,1.589,0.807,72.0,5.28,43.8,4.83,36.2,0.00252912,-0.134466,45.8,1.7908164330634457,5.293615580541143,1.204085310282462e-10,0.4505560487117993,174.72159837435427,13.81076816803118,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG180M2-24/1324x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,180.0,161.8,1.3134080000000001,1.324,0.992,48.0,8.1,29.4,7.47,24.1,0.003321,-0.089082,46.7,1.2069101692613555,8.118254447371243,2.0612178567906154e-10,0.22502079006334322,99.84791295201198,16.388634945681243,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG180S1-36/1589x807,Guangdong Golden Glass Technologies,Mono-c-Si,0,180.0,163.4,1.282323,1.589,0.807,72.0,5.35,44.2,4.93,36.5,0.0025626499999999997,-0.135694,45.8,1.7990211030110337,5.361441144619731,1.1018080104545463e-10,0.4584572263348756,214.3794446207989,12.850748928245677,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG190M2-27/1482x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,190.0,170.5,1.470144,1.482,0.992,54.0,7.8,32.6,7.12,26.7,0.0031980000000000003,-0.098778,46.7,1.3451786283234075,7.823852023256988,2.22193787090199e-10,0.2615202855264251,85.52139456450763,17.492151957330215,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG195M2-27/1482x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,195.0,175.1,1.470144,1.482,0.992,54.0,7.92,32.8,7.25,26.9,0.0032472000000000004,-0.09938399999999999,46.7,1.3523549564254382,7.942067950812554,2.2202266812101483e-10,0.2536530126994552,91.03391369386286,17.329788738879007,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG200M2-27/1482x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,200.0,179.7,1.470144,1.482,0.992,54.0,8.02,33.0,7.38,27.1,0.0032882,-0.09999,46.7,1.3577188697306426,8.03886173165255,2.1485540604301395e-10,0.24700789868916176,105.02765379602603,16.881400613845503,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG205M2-27/1482x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,205.0,184.3,1.470144,1.482,0.992,54.0,8.15,33.2,7.54,27.2,0.0033415000000000003,-0.100596,46.7,1.3601406023831324,8.166544355226076,1.9813773637438886e-10,0.25526814758855354,125.7489617768778,15.948350086939799,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG220M2-30/1640x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,220.0,198.5,1.6268799999999999,1.64,0.992,60.0,7.98,36.6,7.33,30.0,0.0036468600000000005,-0.11309400000000001,46.3,1.5007520099403255,8.000586123312573,1.9647817939506564e-10,0.2855209547188944,110.67927951103806,13.773074432830466,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG225M2-30/1640x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,225.0,203.1,1.6268799999999999,1.64,0.992,60.0,8.1,36.8,7.48,30.1,0.0037017,-0.113712,46.3,1.5027553441433854,8.118176187327318,1.8154753035391782e-10,0.29361529017932236,130.84613627609772,12.893394857000764,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG230M2-30/1640x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,230.0,207.7,1.6268799999999999,1.64,0.992,60.0,8.2,37.0,7.6,30.3,0.0037473999999999993,-0.11433,46.3,1.5089885761212525,8.215773878699071,1.7886451008980426e-10,0.28641857133483123,148.89377677461613,12.632914261160604,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG250M2-35/1956x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,250.0,224.3,1.9403519999999999,1.956,0.992,72.0,7.75,43.3,7.06,35.4,0.0031775,-0.13119899999999998,46.7,1.7868691550792015,7.775581555779457,2.2079681787251127e-10,0.35980730169127845,109.00457788203924,17.50052324211214,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG255M2-35/1956x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,255.0,228.9,1.9403519999999999,1.956,0.992,72.0,7.84,43.5,7.16,35.6,0.0032144,-0.131805,46.7,1.793666788493743,7.863972776054877,2.1965075295887677e-10,0.3517646898574768,115.04029683606421,17.3325860999536,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG260M2-35/1956x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,260.0,233.5,1.9403519999999999,1.956,0.992,72.0,7.92,43.7,7.26,35.8,0.0032472000000000004,-0.132411,46.7,1.7992577985508422,7.941632634595148,2.1502408781450038e-10,0.3445830176035914,126.15650599174849,17.021434459309585,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG270M2-36/1956x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,270.0,242.7,1.9403519999999999,1.956,0.992,72.0,8.1,44.1,7.48,36.1,0.003321,-0.133623,46.7,1.8076301953066962,8.117790240235328,1.9901153177250948e-10,0.34560852257355873,157.35757987788836,16.054052370459303,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG275M2-36/1956x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,275.0,247.3,1.9403519999999999,1.956,0.992,72.0,8.2,44.3,7.6,36.2,0.0033619999999999995,-0.134229,46.7,1.8104687817128036,8.216060051459475,1.882871390353378e-10,0.3533357608340641,180.40747755274458,15.407944879965047,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Guangdong Golden Glass Technologies GG280M2-36/1956x992,Guangdong Golden Glass Technologies,Multi-c-Si,0,280.0,252.0,1.9403519999999999,1.956,0.992,72.0,8.28,44.5,7.7,36.4,0.0033948,-0.134835,46.7,1.8164136513509284,8.293794537382452,1.8522240259574198e-10,0.3463657050259095,207.90172996314914,15.152191004143171,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +HALEE Inc HST-61-E-FP,HALEE Inc,Mono-c-Si,0,61.0,52.2,0.41,,,14.0,8.6,9.5,8.1,7.6,0.0023994,-0.024966,60.5,0.3551735152885725,8.609202723259399,2.0590056950714302e-11,0.10278441315375962,96.05265203106141,11.112867000025277,-0.3867,Y,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-54HT425W,Hanersun Energy Co Ltd,Mono-c-Si,0,425.0,403.2,1.9,,,54.0,14.05,38.1,13.24,32.1,0.0064208500000000005,-0.0893064,43.1,1.3491940172968246,14.063229084742943,7.505856497545384e-12,0.1299867464021378,138.05292087276777,10.152752492629805,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-54HT430W,Hanersun Energy Co Ltd,Mono-c-Si,0,430.0,408.1,1.9,,,54.0,14.12,38.3,13.32,32.3,0.00645284,-0.0897752,43.1,1.3562458063400278,14.132230895741989,7.547095132251023e-12,0.1274038409775447,147.08180617097048,10.152701530900972,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-48HT430W,Hanersun Energy Co Ltd,Mono-c-Si,0,430.0,408.5,1.94,,,48.0,15.76,34.93,14.76,29.14,0.00718656,-0.09581299,43.2,1.230307284572468,15.78436954778118,7.183965036600656e-12,0.12888428806596447,83.35059807788474,-7.161238524940125,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18N-54HT435W,Hanersun Energy Co Ltd,Mono-c-Si,0,435.0,412.9,1.9,,,54.0,14.19,38.5,13.39,32.5,0.00648483,-0.090244,43.1,1.3637678215963456,14.201849190177828,7.655891460119326e-12,0.12479522760802794,149.44854948047703,10.236277959577253,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-48HT435W,Hanersun Energy Co Ltd,Mono-c-Si,0,435.0,413.3,1.94,,,48.0,15.82,35.13,14.85,29.3,0.00721392,-0.09636159000000001,43.2,1.2358588000951516,15.842007001502182,6.986962250618872e-12,0.12974451951547583,93.26842192967398,-7.410658161947738,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18N-54HT440W,Hanersun Energy Co Ltd,Mono-c-Si,0,440.0,417.8,1.9,,,54.0,14.26,38.7,13.46,32.7,0.0065168199999999996,-0.0907128,43.1,1.371288969651256,14.271475836973119,7.765134908700944e-12,0.12221430812509178,151.86483065707228,10.318831110139389,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-48HT440W,Hanersun Energy Co Ltd,Mono-c-Si,0,440.0,418.2,1.94,,,48.0,15.88,35.33,14.94,29.46,0.007241280000000001,-0.09691019,43.2,1.241418167812573,15.899618470951891,6.798378426774152e-12,0.1305920160459322,105.70656718516508,-7.655972370926581,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-54HT445W,Hanersun Energy Co Ltd,Mono-c-Si,0,445.0,422.6,1.9,,,54.0,14.33,38.9,13.53,32.9,0.00654881,-0.0911816,43.1,1.3788092656809297,14.341110688072995,7.874819928901036e-12,0.11966064236468023,154.33220682694602,10.400379532076233,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-48HT445W,Hanersun Energy Co Ltd,Mono-c-Si,0,445.0,423.0,1.94,,,48.0,15.94,35.53,15.03,29.62,0.00726864,-0.09745879,43.2,1.246985246422734,15.957204817448256,6.617764499427507e-12,0.13142705768354637,121.76515730557013,-7.897273038838157,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN21RN-48HT450W,Hanersun Energy Co Ltd,Mono-c-Si,0,450.0,427.9,1.94,,,48.0,16.0,35.73,15.12,29.78,0.007296,-0.09800738999999999,43.2,1.2525598269011347,16.014766791437932,6.444689746114376e-12,0.13224992600745195,143.2944203890672,-8.134661273967774,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN21RN-48HT455W,Hanersun Energy Co Ltd,Mono-c-Si,0,455.0,432.8,1.94,,,48.0,16.06,35.93,15.2,29.94,0.00732336,-0.09855599,43.2,1.2585280587801295,16.073073045724584,6.329178006258429e-12,0.13304202174622676,163.43971549264802,-8.30539019023229,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-60HT475W,Hanersun Energy Co Ltd,Mono-c-Si,0,475.0,450.7,2.11,,,60.0,14.16,42.6,13.34,35.7,0.0064711199999999995,-0.09985440000000001,43.1,1.5048938061182442,14.17480004791218,7.0644864618662204e-12,0.16053191858596638,153.5895009500727,9.535764090766989,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-60HT480W,Hanersun Energy Co Ltd,Mono-c-Si,0,480.0,455.6,2.11,,,60.0,14.21,42.8,13.4,35.9,0.00649397,-0.1003232,43.1,1.5119412644623862,14.223782292729489,7.094479533326666e-12,0.15802115276359174,162.925039459619,9.537961434699053,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-60HT485W,Hanersun Energy Co Ltd,Mono-c-Si,0,485.0,460.4,2.11,,,60.0,14.24,43.0,13.44,36.1,0.006507679999999999,-0.10079199999999999,43.1,1.5190452230852116,14.252850743601357,7.121282081602324e-12,0.15574664674116248,172.58396282927472,9.54911304712499,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-60HT490W,Hanersun Energy Co Ltd,Mono-c-Si,0,490.0,465.3,2.11,,,60.0,14.29,43.2,13.5,36.3,0.00653053,-0.10126080000000001,43.1,1.5260883384259383,14.30189183992849,7.150704734193822e-12,0.1532778361115547,184.1885102298565,9.550500408223368,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-60HT495W,Hanersun Energy Co Ltd,Mono-c-Si,0,495.0,470.1,2.11,,,60.0,14.34,43.4,13.57,36.5,0.006553379999999999,-0.1017296,43.1,1.5326125869259746,14.35032698978723,7.117775380040196e-12,0.1508832851633811,209.5156823545186,9.469989177370367,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18-72HT525W,Hanersun Energy Co Ltd,Mono-c-Si,1,525.0,495.4,2.52,,,72.0,13.65,49.15,12.76,41.15,0.006046950000000001,-0.12444779999999998,43.2,1.786513519805378,13.669671290962217,1.4975704374664177e-11,0.18710092062367947,129.8301965799415,8.134796612394364,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18-72HT530W,Hanersun Energy Co Ltd,Mono-c-Si,1,530.0,500.2,2.52,,,72.0,13.72,49.3,12.83,41.31,0.00607796,-0.12482759999999998,43.2,1.7924035592415057,13.73918726494838,1.5159168350344756e-11,0.18367432667205777,131.33772721366404,8.195701576980296,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18-72HT535W,Hanersun Energy Co Ltd,Mono-c-Si,1,535.0,505.0,2.52,,,72.0,13.79,49.45,12.9,41.47,0.00610897,-0.1252074,43.2,1.7982940003046917,13.80871132283964,1.5343842523982432e-11,0.1802851041789958,132.86776216294197,8.256282146631039,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18-72HT540W,Hanersun Energy Co Ltd,Mono-c-Si,1,540.0,509.9,2.52,,,72.0,13.86,49.6,12.97,41.64,0.00613998,-0.1255872,43.2,1.8044012567870513,13.878163005132262,1.5580673167631948e-11,0.17604939354501797,134.34145852052612,8.345506197362562,-0.3263,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18-72HT545W,Hanersun Energy Co Ltd,Mono-c-Si,1,545.0,514.7,2.52,,,72.0,13.93,49.75,13.04,41.8,0.00617099,-0.125967,43.2,1.8102922698850104,13.94770385441108,1.5768147679810574e-11,0.17273799734297593,135.9161826881517,8.405329163756926,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18-72HT550W,Hanersun Energy Co Ltd,Mono-c-Si,1,550.0,519.5,2.52,,,72.0,14.0,49.9,13.11,41.96,0.006202,-0.12634679999999998,43.2,1.816183656461868,14.017252450879115,1.5956826542092416e-11,0.16946213814175734,137.5149502771891,8.464834305021984,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18-72HT555W,Hanersun Energy Co Ltd,Mono-c-Si,1,555.0,524.4,2.52,,,72.0,14.04,50.2,13.14,42.26,0.00621972,-0.12710639999999998,43.2,1.828638128390978,14.057363336595,1.6363300972938158e-11,0.1657710317545609,134.04251416409681,8.664786110479248,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-72HT570W,Hanersun Energy Co Ltd,Mono-c-Si,0,570.0,540.9,2.52,,,72.0,14.11,51.0,13.32,42.8,0.00644827,-0.119544,43.1,1.801164768062013,14.122628525475927,7.003651837244844e-12,0.18783285810877856,209.8678608655469,9.480753594022298,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-72HT575W,Hanersun Energy Co Ltd,Mono-c-Si,0,575.0,545.8,2.52,,,72.0,14.17,51.2,13.38,43.0,0.006475689999999999,-0.1200128,43.1,1.808663905855157,14.182318732696512,7.083177251989475e-12,0.18505244085054223,212.8622446727887,9.543171638266898,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-72HT580W,Hanersun Energy Co Ltd,Mono-c-Si,0,580.0,550.6,2.52,,,72.0,14.23,51.4,13.43,43.2,0.00650311,-0.12048160000000001,43.1,1.8167836131130803,14.242657443303694,7.2263496457796995e-12,0.1822355809296165,204.8764714254479,9.687762094958481,-0.3071,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18N-72HT585W,Hanersun Energy Co Ltd,Mono-c-Si,0,585.0,555.5,2.52,,,72.0,14.29,51.6,13.48,43.4,0.00653053,-0.1209504,43.1,1.8249047417712811,14.302980762939145,7.371407815281694e-12,0.17943927647581095,197.53748507140256,9.831424572602247,-0.3071,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18N-72HT590W,Hanersun Energy Co Ltd,Mono-c-Si,0,590.0,560.3,2.52,,,72.0,14.35,51.8,13.54,43.6,0.006557949999999999,-0.1214192,43.1,1.8324025051485318,14.362666880356343,7.452706192812108e-12,0.17672992578539656,200.21302399363358,9.8915837093845,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-72HT595W,Hanersun Energy Co Ltd,Mono-c-Si,0,595.0,565.2,2.52,,,72.0,14.41,52.0,13.59,43.8,0.00658537,-0.121888,43.1,1.8405246591679854,14.422970475752669,7.600396894440074e-12,0.17397647493050372,193.28520062227324,10.033499170480363,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-66HT600W,Hanersun Energy Co Ltd,Mono-c-Si,0,600.0,570.3,2.63,,,66.0,15.82,48.32,14.92,40.23,0.00721392,-0.13254176,43.2,1.6946060628888695,15.83711618574433,6.431994658939707e-12,0.18412396887737295,170.1805084530785,-8.056708129483606,-0.2972,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21RN-66HT605W,Hanersun Energy Co Ltd,Mono-c-Si,0,605.0,575.2,2.63,,,66.0,15.88,48.52,14.98,40.41,0.007241280000000001,-0.13309036,43.2,1.7017192863016535,15.896845366935837,6.468646181863293e-12,0.18316845625868122,172.6715186170438,-8.043127519385827,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN21RN-66HT610W,Hanersun Energy Co Ltd,Mono-c-Si,0,610.0,580.0,2.63,,,66.0,15.94,48.72,15.03,40.59,0.00726864,-0.13363896,43.2,1.7093675332268892,15.957347023779178,6.558522451924978e-12,0.18219277491548438,167.4150490612911,-7.96551213008677,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-78HT615W,Hanersun Energy Co Ltd,Mono-c-Si,0,615.0,583.6,2.73,,,78.0,14.14,55.4,13.32,46.18,0.00646198,-0.12985760000000002,43.1,1.9521731900508694,14.156028642626925,6.573661221248992e-12,0.23017990901185223,203.05798781220264,8.901254645977184,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-66HT615W,Hanersun Energy Co Ltd,Mono-c-Si,0,615.0,584.9,2.63,,,66.0,16.0,48.92,15.09,40.77,0.007296,-0.13418756,43.2,1.7164803421984458,16.017077348593496,6.595230486408106e-12,0.18125210867145466,169.81756232732397,-7.9524857902707335,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-78HT620W,Hanersun Energy Co Ltd,Mono-c-Si,0,620.0,588.4,2.73,,,78.0,14.18,55.6,13.37,46.38,0.00648026,-0.1303264,43.1,1.9590680761749126,14.19499858023124,6.584355693930649e-12,0.2275696852259002,215.1495729663204,8.886492932947464,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21RN-66HT620W,Hanersun Energy Co Ltd,Mono-c-Si,0,620.0,589.8,2.63,,,66.0,16.06,49.12,15.15,40.95,0.00732336,-0.13473616,43.2,1.7235929433259845,16.076810584982677,6.631928907378176e-12,0.18031900037125007,172.26783918178532,-7.93959154993518,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18N-78HT625W,Hanersun Energy Co Ltd,Mono-c-Si,0,625.0,593.3,2.73,,,78.0,14.22,55.8,13.42,46.58,0.0064985400000000006,-0.13079519999999997,43.1,1.9659620806305989,14.233991973513195,6.59498890335016e-12,0.2249795173912632,228.64599768164013,8.87171359016054,-0.3071,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN21RN-66HT625W,Hanersun Energy Co Ltd,Mono-c-Si,0,625.0,594.6,2.63,,,66.0,16.12,49.32,15.2,41.13,0.007350720000000001,-0.13528476,43.2,1.7312420365588543,16.137302321833292,6.7226222932834546e-12,0.17936342717703752,167.10696265141914,-7.8632370574548185,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN18N-78HT630W,Hanersun Energy Co Ltd,Mono-c-Si,0,630.0,598.1,2.73,,,78.0,14.26,56.0,13.47,46.78,0.0065168199999999996,-0.13126400000000002,43.1,1.9728552987134231,14.273008410568213,6.605568105754418e-12,0.22240922064803692,243.80807141139456,8.856791711276433,-0.3071,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21RN-66HT630W,Hanersun Energy Co Ltd,Mono-c-Si,0,630.0,599.5,2.63,,,66.0,16.18,49.52,15.26,41.31,0.00737808,-0.13583336000000001,43.2,1.738354232430214,16.197036721594205,6.759372791228134e-12,0.1784446565108272,169.47125249120467,-7.8508555453371205,-0.2972,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN18N-78HT635W,Hanersun Energy Co Ltd,Mono-c-Si,0,635.0,603.0,2.73,,,78.0,14.3,56.2,13.52,46.98,0.0065351,-0.1317328,43.1,1.9797473348427321,14.312047552863538,6.616062538848526e-12,0.21985845216449962,260.9638578229539,8.842085785485578,-0.3071,N,2025.7.3,6/23/2025,2.0,first_pass +Hanersun Energy Co Ltd HN21-66HT635W,Hanersun Energy Co Ltd,Mono-c-Si,1,635.0,599.4,3.03,,,66.0,18.27,44.4,17.03,37.3,0.00836766,-0.1118436,43.3,1.615111693194039,18.2979514366767,2.0399258889116116e-11,0.11804751428500079,77.15982957659786,8.846113523052505,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN18N-78HT640W,Hanersun Energy Co Ltd,Mono-c-Si,0,640.0,607.9,2.73,,,78.0,14.34,56.4,13.57,47.18,0.006553379999999999,-0.13220159999999997,43.1,1.9866385799845048,14.351109008670676,6.626503026536333e-12,0.2173271060725122,280.5354426075195,8.827237621720549,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21-66HT640W,Hanersun Energy Co Ltd,Mono-c-Si,1,640.0,604.2,3.03,,,66.0,18.31,44.6,17.07,37.5,0.00838598,-0.11234740000000001,43.3,1.622954066860073,18.33738474072295,2.064350162675747e-11,0.11618570474552344,77.68414825458613,8.931855400652926,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN18N-78HT645W,Hanersun Energy Co Ltd,Mono-c-Si,0,645.0,612.7,2.73,,,78.0,14.38,56.6,13.62,47.38,0.00657166,-0.13267040000000002,43.1,1.9935289921780612,14.390192482035621,6.636887607059261e-12,0.21481490978394158,303.0702765686484,8.812378928816353,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Energy Co Ltd HN21-66HT645W,Hanersun Energy Co Ltd,Mono-c-Si,1,645.0,609.1,3.03,,,66.0,18.35,44.8,17.11,37.7,0.008404300000000002,-0.1128512,43.3,1.6307952387547706,18.37682487699534,2.0888219095413146e-11,0.11433309116662742,78.21143886522238,9.0166597906304,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21-66HT650W,Hanersun Energy Co Ltd,Mono-c-Si,1,650.0,613.9,3.03,,,66.0,18.39,45.0,17.16,37.9,0.00842262,-0.11335500000000001,43.3,1.6381677058653417,18.415693358129992,2.098280569023643e-11,0.11253837915398292,80.54925270806774,9.03445446683555,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21-66HT655W,Hanersun Energy Co Ltd,Mono-c-Si,1,655.0,618.7,3.03,,,66.0,18.43,45.2,17.2,38.1,0.00844094,-0.11385880000000001,43.3,1.64600499298867,18.45515869341812,2.12269591761136e-11,0.11070530673025711,81.09716881508648,9.117496825418234,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21-66HT660W,Hanersun Energy Co Ltd,Mono-c-Si,1,660.0,623.6,3.03,,,66.0,18.47,45.4,17.24,38.3,0.00845926,-0.11436260000000001,43.3,1.6538411338494494,18.494630485156964,2.1471555036746094e-11,0.10888121021797142,81.6482478539354,9.199631903165562,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21-66HT665W,Hanersun Energy Co Ltd,Mono-c-Si,1,665.0,628.4,3.03,,,66.0,18.51,45.6,17.28,38.5,0.00847758,-0.11486640000000001,43.3,1.6616761039670216,18.53410865628103,2.1716570662230444e-11,0.10706601518854239,82.20250528196637,9.280903869887108,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21-66HT670W,Hanersun Energy Co Ltd,Mono-c-Si,1,670.0,633.3,3.03,,,66.0,18.55,45.8,17.32,38.7,0.0084959,-0.11537019999999999,43.3,1.6695099610599118,18.57359313318614,2.1962007108476226e-11,0.10525966377833774,82.75996035452528,9.361283702578785,-0.3232,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT670W,Hanersun Energy Co Ltd,Mono-c-Si,0,670.0,636.8,3.03,,,66.0,18.1,47.0,17.1,39.2,0.007421000000000001,-0.13348,43.1,1.6382607222580468,18.1173692044794,6.187682256259529e-12,0.15332892181667887,159.78011498815803,-12.411368493664336,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT675W,Hanersun Energy Co Ltd,Mono-c-Si,0,675.0,641.6,3.03,,,66.0,18.14,47.2,17.14,39.4,0.0074374,-0.134048,43.1,1.6458179599642568,18.1570608222332,6.265481580926174e-12,0.151437544097204,161.0166858704936,-12.3374128826927,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT680W,Hanersun Energy Co Ltd,Mono-c-Si,0,680.0,646.5,3.03,,,66.0,18.18,47.4,17.18,39.6,0.0074538,-0.13461599999999999,43.1,1.6533743170318562,18.196755962123213,6.343539934784852e-12,0.14955540707998194,162.2656631127325,-12.2642155439191,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT685W,Hanersun Energy Co Ltd,Mono-c-Si,0,685.0,651.3,3.03,,,66.0,18.22,47.6,17.22,39.8,0.007470200000000001,-0.135184,43.1,1.6609297767788025,18.236454599636982,6.4218512870625476e-12,0.147682432400658,163.5271584821187,-12.191741173157709,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT690W,Hanersun Energy Co Ltd,Mono-c-Si,0,690.0,656.2,3.03,,,66.0,18.26,47.8,17.25,40.0,0.007486600000000001,-0.13575199999999998,43.1,1.6689409076466877,18.276870881500194,6.547126191472675e-12,0.1457919644562328,157.79621683329262,-12.06603405782656,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT695W,Hanersun Energy Co Ltd,Mono-c-Si,0,695.0,661.1,3.03,,,66.0,18.3,48.0,17.29,40.2,0.007503000000000001,-0.13631999999999997,43.1,1.676496064778134,18.316565072667856,6.626423181464827e-12,0.14393570707867254,159.01067846539408,-11.995044597786874,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT700W,Hanersun Energy Co Ltd,Mono-c-Si,0,700.0,665.9,3.03,,,66.0,18.34,48.2,17.33,40.4,0.007519400000000001,-0.136888,43.1,1.6840503202704056,18.35626280711568,6.705958627142131e-12,0.14208843526299467,160.2369067206524,-11.924730794675392,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Energy Co Ltd HN21N-66HT705W,Hanersun Energy Co Ltd,Mono-c-Si,0,705.0,670.8,3.03,,,66.0,18.38,48.4,17.37,40.6,0.0075358,-0.137456,43.1,1.6916037157075567,18.39596405959043,6.785733034571389e-12,0.1402500557523159,161.47496908765115,-11.855114089605296,-0.2957,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hanersun Technology Co Ltd CP17-60HB340W,Hanersun Technology Co Ltd,Mono-c-Si,0,340.0,318.5,1.82,,,60.0,10.99,39.6,10.47,32.5,0.00474768,-0.11539440000000001,43.1,1.4644644378095872,10.990619258913348,1.9819121992205612e-11,0.2495151603856611,4428.151192549752,-2.3327075069609293,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-60HB345W,Hanersun Technology Co Ltd,Mono-c-Si,0,345.0,323.3,1.82,,,60.0,11.05,39.8,10.53,32.8,0.004773600000000001,-0.11597719999999999,43.1,1.4748081260650103,11.050662610260888,2.103166056333738e-11,0.23455304076340378,3911.5145836107213,-1.904721042785479,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-60HB350W,Hanersun Technology Co Ltd,Mono-c-Si,0,350.0,328.1,1.82,,,60.0,11.11,40.1,10.61,33.0,0.00479952,-0.11685140000000001,43.1,1.4853559516227863,11.110004072075137,2.0946376483574986e-11,0.23986236470809102,654442.2243360267,-1.9829054293809272,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-60HB355W,Hanersun Technology Co Ltd,Mono-c-Si,0,355.0,332.9,1.82,,,60.0,11.18,40.4,10.66,33.3,0.00482976,-0.11772559999999999,43.1,1.4967594803493491,11.180159558258884,2.1185087197788172e-11,0.23474228950874543,16448.03689448649,-1.942119282307527,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-72HB410W,Hanersun Technology Co Ltd,Mono-c-Si,0,410.0,384.2,2.17,,,72.0,10.96,48.0,10.39,39.5,0.004734720000000001,-0.139872,43.1,1.7817630861482487,10.965308904395037,2.173330014443138e-11,0.2913857682513777,601.5531356030468,-1.5583691624061464,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-72HB415W,Hanersun Technology Co Ltd,Mono-c-Si,0,415.0,389.0,2.17,,,72.0,11.03,48.2,10.46,39.7,0.00476496,-0.14045480000000002,43.1,1.7897122311238245,11.035020980319599,2.2052708777214086e-11,0.28685268802109215,630.1528915569661,-1.4938673033647918,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-72HB420W,Hanersun Technology Co Ltd,Mono-c-Si,0,420.0,393.8,2.17,,,72.0,11.1,48.4,10.53,39.9,0.0047952,-0.14103759999999999,43.1,1.7976617062890219,11.104740070819545,2.237436216284039e-11,0.28238020566370076,661.2602354093713,-1.4298669855643085,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-72HB425W,Hanersun Technology Co Ltd,Mono-c-Si,0,425.0,398.6,2.17,,,72.0,11.17,48.6,10.6,40.1,0.00482544,-0.1416204,43.1,1.8056115107370436,11.174466060619308,2.2698254480250724e-11,0.2779671145446459,695.2195696392608,-1.3663617168052495,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hanersun Technology Co Ltd CP17-72HB430W,Hanersun Technology Co Ltd,Mono-c-Si,0,430.0,403.4,2.17,,,72.0,11.24,48.8,10.67,40.3,0.00485568,-0.1422032,43.1,1.8135620142277191,11.244198821858527,2.302450687571461e-11,0.27361216335693445,732.4437409078321,-1.303301456105291,-0.3531,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS240ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,240.0,214.4,1.60066,1.63,0.982,60.0,8.31,37.7,7.93,30.3,0.004155000000000001,-0.12064000000000002,48.1,1.5383451753701112,8.310002782167237,1.8897654792326657e-10,0.3346812515025845,999999.0593071549,8.956514352445978,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS245ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,245.0,219.0,1.60066,1.63,0.982,60.0,8.44,37.8,8.07,30.4,0.004220000000000001,-0.12096,48.1,1.5442994504200653,8.440002689318458,1.9772579233130383e-10,0.31852458370689024,999984.6682876986,9.217900794476824,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS250ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,250.0,223.6,1.60066,1.63,0.982,60.0,8.57,37.9,8.2,30.5,0.004285,-0.12128,48.1,1.5493442004687457,8.570002646262669,2.0383728665954868e-10,0.30866268212307657,999960.9538878303,9.351368719933927,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS250NB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,250.0,228.9,1.67,1.67,1.0,60.0,8.96,36.8,8.43,29.7,0.0035840000000000004,-0.1104,44.11,1.4570428513124047,8.967743826396475,9.531055105920022e-11,0.32777001726677474,379.2465688152016,9.523100795766183,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS255ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,255.0,228.2,1.60066,1.63,0.982,60.0,8.71,38.0,8.34,30.6,0.004355,-0.1216,48.1,1.5544139491336004,8.710002601373677,2.103928225034923e-10,0.29855077709469985,999966.8931981961,9.48760428312501,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS255NB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,255.0,233.6,1.67,1.67,1.0,60.0,9.01,37.2,8.49,30.1,0.003604,-0.11160000000000002,44.11,1.4738161298624088,9.016381121781793,9.753980116276087e-11,0.31886861775331393,450.23533612342356,9.67266269331722,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS255NB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,255.0,233.5,1.617,,,60.0,9.01,37.2,8.49,30.1,0.0041446,-0.11308800000000001,45.6,1.4425672316842508,9.0174194179654,5.6394129203467674e-11,0.3266375839970769,396.6624869300143,3.483595399555129,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS255SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,255.0,230.2,1.60066,1.63,0.982,60.0,8.74,37.9,8.23,31.0,0.0041952000000000005,-0.124312,45.8,1.5775018617010377,8.744746945079832,3.190688824576597e-10,0.27053695701501645,498.1084712573569,10.466294046703842,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS260ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,260.0,233.9,1.67,1.67,1.0,60.0,8.85,38.1,8.48,30.7,0.004425,-0.11811,47.94,1.5246199126555997,8.85024019862454,1.241191464206901e-10,0.30058526126051605,11074.94270483787,8.199558515890619,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS260NB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,260.0,238.2,1.67,1.67,1.0,60.0,9.07,37.6,8.54,30.5,0.003628,-0.1128,44.11,1.4922696421916437,9.077059699898703,1.0249228551390668e-10,0.30970340840654104,397.8937039344016,10.05582935080384,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS260NB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,260.0,238.2,1.617,,,60.0,9.07,37.6,8.54,30.5,0.0041722,-0.114304,45.6,1.4606100075145128,9.078092192199827,5.92941552265715e-11,0.3175449323552364,355.91500995576223,3.8509856139490406,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS260PB-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,260.0,239.4,1.61,,,60.0,9.03,37.3,8.54,30.5,0.0042441,-0.113019,44.77,1.4439071990602446,9.034508697662334,5.4170493307781116e-11,0.2853196084628215,571.4366709148891,3.450898405798106,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS260SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,260.0,234.9,1.60066,1.63,0.982,60.0,8.88,38.0,8.37,31.1,0.0042624,-0.12464,45.8,1.5813729221673651,8.884139418424985,3.231026475288683e-10,0.26452340668857777,567.463405888089,10.433057241670982,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS265ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,265.0,238.5,1.67,1.67,1.0,60.0,8.98,38.2,8.61,30.8,0.00449,-0.11842000000000001,47.94,1.5295006976733974,8.980237260021125,1.2776481465253327e-10,0.291643249884803,11038.36509162234,8.324848683445246,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS265NB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,265.0,242.9,1.67,1.67,1.0,60.0,9.12,38.0,8.59,30.9,0.0036479999999999998,-0.11399999999999999,44.11,1.5098985636024422,9.126755163037208,1.0613159634823074e-10,0.3010168223524071,406.3963797758016,10.315922772003992,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS265NB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,265.0,242.9,1.617,,,60.0,9.12,38.0,8.59,30.9,0.0041952,-0.11552,45.6,1.4778538562016807,9.127758297726963,6.142696360858463e-11,0.3089218488802037,363.1424818673028,4.100630945617804,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS265PB-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,265.0,244.1,1.61,,,60.0,9.08,37.7,8.59,30.9,0.0042676,-0.11423100000000001,44.77,1.4610120523890784,9.084288220026288,5.606066567880915e-11,0.27694094167140537,586.4027232474454,3.690784491858903,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS265SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,265.0,239.5,1.60066,1.63,0.982,60.0,9.01,38.1,8.5,31.2,0.0043248,-0.12496800000000001,45.8,1.585321699273583,9.01358649956223,3.2709772124284333e-10,0.2589780495594023,650.6045495383753,10.409848097878454,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS270ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,270.0,243.2,1.67,1.67,1.0,60.0,9.12,38.3,8.75,30.9,0.00456,-0.11873,47.94,1.5344035430228768,9.120233924096846,1.3166963605638802e-10,0.2824649273526061,11012.488419899286,8.452624337192589,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS270NB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,270.0,247.6,1.67,1.67,1.0,60.0,9.16,38.4,8.63,31.3,0.003664,-0.1152,44.11,1.5275727023626067,9.166504350846246,1.0977627530768058e-10,0.2927526271872484,412.280079241295,10.576835971953624,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS270NB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,270.0,247.6,1.617,,,60.0,9.16,38.4,8.63,31.3,0.0042136,-0.116736,45.6,1.4951413053911002,9.16747916500197,6.356445587831161e-11,0.3007301145312665,368.31492260333545,4.351005713775983,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS270PB-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,270.0,248.8,1.61,,,60.0,9.13,38.1,8.64,31.3,0.0042911,-0.115443,44.77,1.4781109774643815,9.134073145655517,5.797079015835695e-11,0.26866469613385335,602.2148486928696,3.924802835788302,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS270SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,270.0,244.2,1.60066,1.63,0.982,60.0,9.14,38.2,8.63,31.3,0.004387200000000001,-0.12529600000000002,45.8,1.5892882068400327,9.143044948269207,3.31157273107188e-10,0.25359234250360657,761.2066215329319,10.388991565847338,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS275NB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,275.0,252.3,1.617,,,60.0,9.21,38.8,8.68,31.7,0.004236600000000001,-0.11795199999999999,45.6,1.5123724654902098,9.217158478919126,6.574447633104601e-11,0.2923049938631389,376.0755805390192,4.588612904952807,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS275PB-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,275.0,253.6,1.61,,,60.0,9.18,38.5,8.69,31.7,0.0043146,-0.116655,44.77,1.4952041072946862,9.183863630381456,5.990020022984377e-11,0.2604889301285969,618.9226843664652,4.153154420474104,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS275SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,275.0,248.8,1.60066,1.63,0.982,60.0,9.28,38.3,8.77,31.4,0.0044544,-0.125624,45.8,1.5932188885091403,9.282473347816154,3.353997912259501e-10,0.24809890792713327,930.8673935596731,10.363700982996125,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS275TB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,275.0,246.3,1.67,1.67,1.0,60.0,9.41,38.3,8.88,31.0,0.0037640000000000004,-0.13022,46.17,1.6209691944122346,9.412213483913874,5.138175472189808e-10,0.28865725047620827,1227.1453174737464,10.136082718469476,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS280PB-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,280.0,258.3,1.61,,,60.0,9.22,38.9,8.73,32.1,0.0043334,-0.117867,44.77,1.5123377341032875,9.223697603696179,6.18253321630064e-11,0.25268017444650426,630.059774463397,4.382275284918789,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS280SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,280.0,253.5,1.60066,1.63,0.982,60.0,9.41,38.4,8.9,31.5,0.0045168000000000005,-0.125952,45.8,1.5972195818327255,9.411954512362021,3.395868597798913e-10,0.24302158931927464,1170.028118310703,10.347351582455925,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS280TB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,280.0,250.9,1.67,1.67,1.0,60.0,9.45,38.7,8.92,31.4,0.00378,-0.13158,46.17,1.6399725737817006,9.452130110539315,5.316622117139913e-10,0.28035891995788587,1243.78250161849,10.401914524138016,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS280TB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,280.0,255.4,1.617,,,60.0,9.45,38.7,8.92,31.4,0.0034019999999999996,-0.11223,47.0,1.484305311306094,9.45670729999987,4.4510858110522556e-11,0.316857182874232,446.424121142144,6.176097448451078,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS285TB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,285.0,255.6,1.67,1.67,1.0,60.0,9.5,39.1,8.97,31.8,0.0038,-0.13294,46.17,1.6589147316661068,9.501997162926154,5.498853728666543e-10,0.2718596466825031,1293.1688935228321,10.654999897237332,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS285TB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,285.0,260.1,1.617,,,60.0,9.5,39.1,8.97,31.8,0.00342,-0.11338999999999999,47.0,1.5013022590799308,9.506435070264128,4.605642375412787e-11,0.30867289413721555,455.6892934502706,6.422709786016871,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS285UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,285.0,262.7,1.67,,,60.0,9.62,39.1,9.11,31.3,0.0043289999999999995,-0.10908900000000002,45.6,1.4631743388052418,9.623896730155874,2.3763257462699603e-11,0.3741237028551512,923.6129023552178,4.652950062487202,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS290TB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,290.0,260.2,1.67,1.67,1.0,60.0,9.54,39.5,9.01,32.2,0.003816,-0.1343,46.17,1.6779054038291925,9.541912244585287,5.68106092211222e-10,0.2637301670945867,1315.7251907529014,10.908686079724891,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS290TB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,290.0,264.8,1.617,,,60.0,9.54,39.5,9.01,32.2,0.0034343999999999998,-0.11455,47.0,1.518339418243125,9.546215548633205,4.7603329527939255e-11,0.30089836042156215,461.83702380107223,6.6699187032264655,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS290UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,290.0,266.9,1.61,,,60.0,9.67,39.5,9.16,31.7,0.0041581,-0.11138999999999999,46.06,1.487472981608946,9.673475843417918,2.825485547372971e-11,0.3640990753986242,1012.9450364322004,4.973139325398901,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS290UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,290.0,265.2,1.61,,,60.0,9.67,39.5,9.16,31.7,0.004061400000000001,-0.11138999999999999,47.1,1.499022794370567,9.673065809794164,3.4683984690526914e-11,0.3614276749585244,1139.9943932642252,6.736719211519306,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS295ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,295.0,264.9,1.912936,1.948,0.982,72.0,8.61,45.0,8.09,36.5,0.004305,-0.14850000000000002,46.7,1.8681270582069034,8.616378200308722,2.946763306480864e-10,0.370012476091462,499.48385559749266,9.20400790857975,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS295TB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,295.0,264.8,1.67,1.67,1.0,60.0,9.59,39.9,9.05,32.6,0.003836,-0.13566000000000003,46.17,1.69783875961664,9.592603553555769,5.941403140720626e-10,0.2552901616970419,940.3433269309779,11.267470533888396,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS295TB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,295.0,269.5,1.617,,,60.0,9.59,39.9,9.05,32.6,0.0034523999999999996,-0.11571,47.0,1.5361597828866866,9.596889318485461,4.9816609970805265e-11,0.2928554203770659,407.65767946824053,7.020077223667373,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS295UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,295.0,271.6,1.61,,,60.0,9.71,39.9,9.2,32.1,0.0041753,-0.11251799999999999,46.06,1.5042997420997302,9.71339303761608,2.926875834534705e-11,0.35628636250803686,1019.5999051699245,5.237486663163521,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS295UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,295.0,269.9,1.61,,,60.0,9.71,39.9,9.2,32.1,0.004078200000000001,-0.11251799999999999,47.1,1.515987182391784,9.712994213680656,3.592426784708401e-11,0.3535897620008373,1146.6639668186253,7.004158026863482,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS295UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,295.0,274.0,1.611,,,60.0,9.44,39.6,8.81,33.5,0.003776,-0.11088000000000002,44.96,1.5050754477365027,9.450164809360416,3.436905114115292e-11,0.1582698890625527,146.98433644993187,7.752242293362946,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,300.0,269.5,1.912936,1.948,0.982,72.0,8.72,45.1,8.2,36.6,0.004360000000000001,-0.14883000000000002,46.7,1.8720320065902338,8.725818184268608,2.977656400206958e-10,0.3635106506663557,544.8114819476694,9.181192569432202,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300ND-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,300.0,270.5,1.994,1.994,1.0,72.0,8.97,44.5,8.46,35.5,0.004485,-0.13795,47.29,1.7667504702645527,8.974630900663797,1.0274176016622353e-10,0.44882519604118803,869.3692810247394,6.4643594734073595,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300TB-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,300.0,269.5,1.67,1.67,1.0,60.0,9.64,40.3,9.1,33.0,0.0038560000000000005,-0.13702,46.17,1.7167699705534512,9.642444880000397,6.13132283795864e-10,0.24706281460639076,974.1530572836026,11.503163373480941,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300TB-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,300.0,274.2,1.617,,,60.0,9.64,40.3,9.1,33.0,0.0034704000000000002,-0.11686999999999999,47.0,1.553147491882228,9.646599492101302,5.143032972469378e-11,0.2849319458508342,416.2053524692452,7.249709391840816,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,300.0,276.3,1.61,,,60.0,9.75,40.3,9.24,32.5,0.0041925,-0.11364599999999998,46.06,1.521121385307385,9.753306035912917,3.029514470924624e-11,0.348546600707314,1027.9167196224753,5.495861605142172,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,300.0,274.6,1.61,,,60.0,9.75,40.3,9.24,32.5,0.0040950000000000005,-0.11364599999999998,47.1,1.5329463934690277,9.752918146305339,3.7179674844010785e-11,0.3458250480191304,1155.4576837308732,7.265557417181902,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS300UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,300.0,278.7,1.611,,,60.0,9.54,39.8,8.91,33.7,0.003816,-0.11144,44.96,1.5128167246504485,9.549728680858665,3.4845635759704564e-11,0.15356945513337292,150.5910796991162,7.777485148328274,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,305.0,274.2,1.912936,1.948,0.982,72.0,8.84,45.2,8.32,36.7,0.00442,-0.14916000000000001,46.7,1.8758843079778462,8.845217972240592,3.009984582419937e-10,0.35677561287080933,604.4296649781716,9.152869541425291,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305ND-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,305.0,275.1,1.994,1.994,1.0,72.0,9.02,44.9,8.5,35.9,0.00451,-0.13919,47.29,1.7855910682744562,9.025630509147726,1.075826365110564e-10,0.4392281043045773,703.6376270111646,6.816244086133835,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,305.0,279.1,1.93452,,,72.0,9.02,44.9,8.5,35.9,0.004059,-0.137843,45.57,1.7345739006508705,9.027219674758765,5.1269398755567796e-11,0.45174632987338753,564.3955312828278,1.6807711649918977,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,305.0,272.8,1.912936,1.948,0.982,72.0,8.76,45.9,8.18,37.3,0.00438,-0.15147000000000002,47.7,1.9138367196447326,8.771150913125252,3.304946143907072e-10,0.3602962927543969,283.0437186802859,10.089996011034142,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,305.0,281.0,1.61,,,60.0,9.79,40.7,9.28,32.9,0.004209699999999999,-0.114774,46.06,1.537937981073316,9.793215550581953,3.13336457491885e-11,0.3408786818312392,1037.8323900678156,5.748452074748778,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,305.0,279.3,1.61,,,60.0,9.79,40.7,9.28,32.9,0.0041118,-0.114774,47.1,1.5499005605629574,9.792838326081707,3.844979503529636e-11,0.33813240974417835,1166.2918704069061,7.5211113787450365,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,305.0,283.5,1.611,,,60.0,9.63,40.0,9.0,33.9,0.0038520000000000004,-0.11200000000000002,44.96,1.5206208105963768,9.639324697110313,3.5322126067356684e-11,0.14911095444085967,153.9930447952978,7.811436244054756,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS305UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,305.0,285.3,1.611,,,60.0,9.63,40.0,9.0,33.9,0.0043335000000000005,-0.11200000000000002,43.35,1.5250999157573528,9.63920722363007,3.816413474571737e-11,0.1479976842414236,154.79342802302793,8.420403863991668,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,310.0,278.8,1.912936,1.948,0.982,72.0,8.95,45.3,8.43,36.8,0.004475,-0.14948999999999998,46.7,1.879824314617038,8.954676580515269,3.041839289228405e-10,0.35060894058963316,670.9925162448,9.13396018058523,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310ND-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,310.0,279.8,1.994,1.994,1.0,72.0,9.07,45.3,8.55,36.3,0.004535,-0.14043,47.29,1.8033941205276471,9.075390332298076,1.1109198088902863e-10,0.4296812305435703,722.9998379299162,7.044751172273509,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,310.0,283.8,1.93452,,,72.0,9.07,45.3,8.55,36.3,0.0040815,-0.13907099999999997,45.57,1.7518345751950206,9.076942732473048,5.295685984627088e-11,0.4422798632319789,577.7953631772182,1.9006664492676162,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,310.0,277.4,1.912936,1.948,0.982,72.0,8.88,46.0,8.3,37.4,0.00444,-0.15180000000000002,47.7,1.9175767237667463,8.890521881039499,3.3358877695997826e-10,0.35364250794576874,298.45859987084935,10.04853442259659,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,310.0,285.8,1.61,,,60.0,9.83,41.1,9.32,33.3,0.0042269,-0.11590199999999999,46.06,1.5547496636770526,9.833122212815475,3.2383933315197597e-11,0.33328151428680797,1049.3062851817904,5.995440513892216,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,310.0,284.1,1.61,,,60.0,9.83,41.1,9.32,33.3,0.0041286000000000005,-0.11590199999999999,47.1,1.5668496844151676,9.832755408430923,3.973414077644983e-11,0.3305107775551187,1179.1069638022627,7.770992634636995,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,310.0,288.3,1.611,,,60.0,9.73,40.2,9.1,34.1,0.0038920000000000005,-0.11256000000000002,44.96,1.5283723122531507,9.738913428618783,3.580765198593108e-11,0.1446057159925807,157.85324428160408,7.837557874306377,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS310UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,310.0,290.1,1.611,,,60.0,9.73,40.2,9.1,34.1,0.0043785000000000004,-0.11256000000000002,43.35,1.532875089292475,9.738798094675603,3.8688994413953314e-11,0.1434983489082355,158.69787669204194,8.44680599936602,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,315.0,283.4,1.912936,1.948,0.982,72.0,9.06,45.4,8.54,36.9,0.00453,-0.14982,46.7,1.8837797563752137,9.064144114556482,3.0741385247880145e-10,0.3445946186244538,753.3643616464063,9.116754856664972,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315ND-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,315.0,284.4,1.994,1.994,1.0,72.0,9.12,45.7,8.59,36.7,0.00456,-0.14167000000000002,47.29,1.8222481731496638,9.12629889392924,1.1616445665895179e-10,0.4202731148544214,608.5022797802943,7.386944174949527,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,315.0,288.5,1.93452,,,72.0,9.12,45.7,8.59,36.7,0.004103999999999999,-0.140299,45.57,1.7700976349916566,9.127848393576457,5.539921373074383e-11,0.43298089974778314,503.13305870577875,2.230250309894377,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,315.0,289.6,1.92,,,72.0,9.08,44.9,8.71,36.2,0.0050848,-0.133802,45.72,1.7261813844752598,9.080281347682408,4.585722030289025e-11,0.3630206134864788,11715.86047335284,3.6119308129621204,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS315SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,315.0,282.0,1.912936,1.948,0.982,72.0,8.99,46.1,8.41,37.5,0.004495000000000001,-0.15213000000000002,47.7,1.9214186591762918,8.999950327850172,3.3667030221798336e-10,0.3475460719287236,314.0036846761199,10.017855698404226,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,315.0,290.5,1.61,,,60.0,9.86,41.5,9.35,33.7,0.004239799999999999,-0.11703,46.06,1.5715978963925559,9.86307719326015,3.3432838565493416e-11,0.32608497763875166,1044.8476394659479,6.242639057261104,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,315.0,288.8,1.61,,,60.0,9.86,41.5,9.35,33.7,0.0041412,-0.11703,47.1,1.583835995437826,9.862720487499349,4.101663302515349e-11,0.32328683461240515,1171.7048878956157,8.021112174022822,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315UB-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,315.0,293.5,1.658,,,60.0,9.68,40.8,9.08,34.7,0.0037752,-0.109344,45.06,1.522895174469941,9.687809001083915,2.1908257808198072e-11,0.14356195039574868,177.95870056883038,8.361778531091305,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,315.0,293.0,1.611,,,60.0,9.82,40.4,9.19,34.3,0.003928,-0.11312,44.96,1.5361845175921858,9.828532694525553,3.6292259077234297e-11,0.14032451820030717,161.49491501332585,7.871997724112181,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS315UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,315.0,294.9,1.611,,,60.0,9.82,40.4,9.19,34.3,0.004419,-0.11312,43.35,1.540711147178298,9.828419401847967,3.9212746026899695e-11,0.13922166480404338,162.3816967238811,8.481545056346922,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,320.0,288.1,1.912936,1.948,0.982,72.0,9.17,45.5,8.65,37.0,0.0045850000000000005,-0.15015,46.7,1.8877502824404384,9.173620458118673,3.1068855127955384e-10,0.33872703504784574,857.9378421247914,9.10120779917186,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320ND-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,320.0,289.0,1.994,1.994,1.0,72.0,9.16,46.1,8.63,37.1,0.00458,-0.14291,47.29,1.8401073920524242,9.1660940413337,1.197588502357833e-10,0.41139271961681095,618.3675541382355,7.612777781859854,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,320.0,293.2,1.93452,,,72.0,9.16,46.1,8.63,37.1,0.004122,-0.14152700000000001,45.57,1.7874122596130155,9.167608292992714,5.712984776499875e-11,0.42419442433889387,510.70863362029075,2.4476316260596165,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,320.0,294.3,1.92,,,72.0,9.12,45.3,8.75,36.6,0.005107199999999999,-0.13499399999999998,45.72,1.7428153458948163,9.120003424710179,4.6948883705327846e-11,0.35595296914204866,947972.5908390912,3.770944441530973,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS320SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,320.0,286.6,1.912936,1.948,0.982,72.0,9.1,46.2,8.52,37.6,0.00455,-0.15246,47.7,1.925278977704181,9.109387728840773,3.398041528129531e-10,0.3415992504962644,331.1294653773842,9.989206979338102,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320UB-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,320.0,295.3,1.61,,,60.0,9.9,41.9,9.39,34.1,0.0042569999999999995,-0.11815799999999999,46.06,1.5884002284612804,9.902978072870424,3.450526323979359e-11,0.31861669938869874,1059.1764213260624,6.4789190157126555,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320UB-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,320.0,293.5,1.61,,,60.0,9.9,41.9,9.39,34.1,0.004158,-0.11815799999999999,47.1,1.600775810589794,9.902631308653115,4.232787116367332e-11,0.31579451754224314,1188.1411240693426,8.26017848613383,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320UB-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,320.0,298.3,1.658,,,60.0,9.77,41.0,9.17,34.9,0.0038103,-0.10988000000000002,45.06,1.530560429195826,9.777465676421858,2.2203727876984703e-11,0.13932256104633758,182.32526389894485,8.395666895265627,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS320UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,320.0,297.8,1.611,,,60.0,9.91,40.6,9.28,34.5,0.0039640000000000005,-0.11368000000000002,44.96,1.5440001920684292,9.918162952481984,3.6780696900934035e-11,0.13612528547328906,165.25902736355638,7.906574052454502,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HS320UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,320.0,299.7,1.611,,,60.0,9.91,40.6,9.28,34.5,0.0044595,-0.11368000000000002,43.35,1.548550671006346,9.918051703112202,3.974062302172733e-11,0.1350268584522966,166.1904515953534,8.516417174935215,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325ME-V01,Hansol Technics Co Ltd,Multi-c-Si,0,325.0,292.7,1.912936,1.948,0.982,72.0,9.29,45.6,8.77,37.1,0.004645,-0.15048,46.7,1.8916719016946653,9.293057858548417,3.141157068347515e-10,0.33264821031281483,1010.6102468521927,9.080562537293643,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325ND-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,325.0,293.7,1.994,1.994,1.0,72.0,9.2,46.5,8.67,37.5,0.0046,-0.14415,47.29,1.857960729757406,9.20589134510542,1.2339104335601785e-10,0.4025997959885141,628.7050754540544,7.83406362399871,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,325.0,297.9,1.93452,,,72.0,9.2,46.5,8.67,37.5,0.00414,-0.142755,45.57,1.804721431566814,9.207371033220664,5.887931937075477e-11,0.4154943902477029,518.5906098683141,2.6606540458831534,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,325.0,299.0,1.92,,,72.0,9.16,45.7,8.79,37.0,0.0051296,-0.136186,45.72,1.7599811213298338,9.16000334725874,4.8408469623195e-11,0.34719810574945675,950200.5149677456,3.991155072626106,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS325SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,325.0,291.2,1.912936,1.948,0.982,72.0,9.21,46.3,8.63,37.7,0.004605000000000001,-0.15279,47.7,1.9291569304083105,9.218833975606746,3.4298916054436317e-10,0.33579664268439213,350.09011264680856,9.962498144933932,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,325.0,293.9,1.994,1.994,1.0,72.0,9.2,46.5,8.67,37.5,0.00368,-0.14415,46.1,1.8801864203707412,9.205298827074412,1.6597871068927642e-10,0.3972593353528855,689.7350147758254,10.558358661059147,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325UB-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,325.0,303.1,1.658,,,60.0,9.86,41.2,9.26,35.1,0.0038453999999999997,-0.11041600000000001,45.06,1.5382290472810463,9.867132473439828,2.2501522034106986e-11,0.13516450090175056,186.85269776986792,8.429703407256676,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325UB-JH2 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,325.0,302.6,1.611,,,60.0,10.0,40.8,9.37,34.7,0.004,-0.11424000000000001,44.96,1.551818917499808,10.007803980901222,3.727273688445201e-11,0.13200576660200453,169.15183304274055,7.941225898261039,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS325UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,325.0,304.5,1.611,,,60.0,10.0,40.8,9.37,34.7,0.0045,-0.11424000000000001,43.35,1.5563935773885873,10.007694770385482,4.02726027505074e-11,0.13091161995622982,170.13063978066032,8.55138021908813,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS330ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,330.0,302.6,1.93452,,,72.0,9.24,46.9,8.71,37.9,0.004158,-0.143983,45.57,1.8220252489244715,9.247136808871227,6.064718505580141e-11,0.4068794561946665,526.7853541277658,2.8694429942399204,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS330PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,330.0,303.7,1.92,,,72.0,9.2,46.1,8.83,37.4,0.005152,-0.137378,45.72,1.777147938885787,9.200003270173076,4.988794548869902e-11,0.338509001392954,952398.3504534377,4.207675519863666,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS330SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,330.0,295.9,1.912936,1.948,0.982,72.0,9.32,46.4,8.74,37.8,0.00466,-0.15312,47.7,1.9330518083759478,9.328288961818087,3.462242321835262e-10,0.330133102413085,371.19738111540147,9.93764394807095,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS330TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,330.0,298.6,1.994,1.994,1.0,72.0,9.24,46.9,8.71,37.9,0.0036960000000000005,-0.14539,46.1,1.8982541736700873,9.245112888246483,1.7087840302696275e-10,0.38851608796364034,702.1255217845362,10.778450647977468,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS330TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,330.0,305.2,1.93452,,,72.0,9.46,45.8,8.88,37.2,0.0035948000000000004,-0.128698,44.49,1.7364360567734638,9.472570180909772,3.2665162584097596e-11,0.3756858311982061,282.73165286059293,6.887895641299055,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS330UB-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,330.0,307.8,1.658,,,60.0,9.95,41.4,9.35,35.3,0.0038805,-0.110952,45.06,1.545900925508263,9.956809184956155,2.2801622278234685e-11,0.1310854529449975,191.55012849287556,8.46387136935886,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS330UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,330.0,309.3,1.611,,,60.0,10.09,41.0,9.46,34.9,0.0045405,-0.11480000000000001,43.35,1.564239601142249,10.097348382779176,4.080855293556788e-11,0.12687369903997173,174.2091655793971,8.586481908365464,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS335ND-AN4,Hansol Technics Co Ltd,Multi-c-Si,0,335.0,307.3,1.93452,,,72.0,9.28,47.3,8.75,38.3,0.004175999999999999,-0.14521099999999998,45.57,1.8393237934729703,9.286905809206836,6.243299324548309e-11,0.398348318122035,535.2989776275164,3.074114679693422,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS335PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,335.0,308.4,1.92,,,72.0,9.24,46.5,8.87,37.8,0.005174400000000001,-0.13857,45.72,1.7943154596790278,9.240003048562285,5.138687660147875e-11,0.32988589686901937,999938.6256775626,4.420560976211906,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS335SE-V01,Hansol Technics Co Ltd,Mono-c-Si,0,335.0,300.5,1.912936,1.948,0.982,72.0,9.43,46.5,8.85,37.9,0.0047150000000000004,-0.15345,47.7,1.9369629400869424,9.437752583166539,3.4950834359860693e-10,0.3246037237594223,394.8378892396036,9.914563693867079,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS335TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,335.0,303.3,1.994,1.994,1.0,72.0,9.5,46.2,8.92,37.6,0.0038,-0.14322000000000001,46.1,1.88108875511086,9.508560781678792,2.0232954380903844e-10,0.3371595829867111,374.14998914669343,12.062797766790803,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS335TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,335.0,309.9,1.93452,,,72.0,9.5,46.2,8.92,37.6,0.00361,-0.12982200000000002,44.49,1.753207543192565,9.512185987214167,3.360923696870355e-11,0.36760019670780225,286.57521668590215,7.097023139048372,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS335UB-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,335.0,312.6,1.658,,,60.0,10.04,41.6,9.44,35.5,0.0039156,-0.11148800000000002,45.06,1.553575957057323,10.046495610090732,2.310400285072809e-11,0.127083191418623,196.42730978155606,8.498153823642783,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS335UB-JH2 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,335.0,314.1,1.611,,,60.0,10.18,41.2,9.55,35.1,0.004581,-0.11536000000000002,43.35,1.572088975025769,10.187012319413727,4.134865442822744e-11,0.12291091800951785,178.43356533294792,8.621668955344933,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS340PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,340.0,313.2,1.92,,,72.0,9.28,46.9,8.91,38.2,0.0051968,-0.139762,45.72,1.8120554833349671,9.28024858370144,5.331810198058802e-11,0.31945724116914853,11925.825213941594,4.696955270072736,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS340TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,340.0,307.9,1.994,1.994,1.0,72.0,9.54,46.6,8.95,38.0,0.003816,-0.14446,46.1,1.9002864102176744,9.54916137119973,2.1071384887190657e-10,0.32882641571608906,342.41646161721224,12.395730364998366,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS340TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,340.0,314.6,1.93452,,,72.0,9.54,46.6,8.95,38.0,0.0036252,-0.130946,44.49,1.7709426048349053,9.552791173914475,3.5016740468549496e-11,0.3595638814007585,268.1723747365728,7.419884646483339,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS340UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,340.0,310.6,1.934,,,72.0,9.5,46.1,8.88,38.3,0.003895,-0.12954100000000002,47.3,1.7875396623271644,9.512199932293598,5.854665343032159e-11,0.2609997642034168,203.23865214732572,11.982700914787491,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS345PD-AN1,Hansol Technics Co Ltd,Multi-c-Si,0,345.0,317.9,1.92,,,72.0,9.31,47.3,8.94,38.6,0.0052136000000000005,-0.140954,45.72,1.8294707656455342,9.310354174637816,5.498465843636278e-11,0.31062043583185145,8165.111625689422,4.930798999646097,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS345TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,345.0,312.6,1.994,1.994,1.0,72.0,9.58,47.0,8.99,38.4,0.003832,-0.1457,46.1,1.9183827617707363,9.588839000617188,2.1650507393693877e-10,0.3206602092607992,347.54212997381876,12.60292319613623,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS345TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,345.0,319.4,1.93452,,,72.0,9.58,47.0,8.99,38.4,0.0036404,-0.13207000000000002,44.49,1.7877113804574167,9.592392164360483,3.598868029776295e-11,0.3516186023011048,271.8254992939441,7.620603578050998,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS345UD-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,345.0,318.1,1.92,,,72.0,9.55,46.4,8.94,38.6,0.004202,-0.130384,45.73,1.7864174134196003,9.561426208375412,4.901999918367402e-11,0.2580559037185439,215.68256336451537,10.302993286203897,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS345UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,345.0,315.3,1.94,,,72.0,9.55,46.4,8.94,38.6,0.003915500000000001,-0.130384,47.3,1.7990661567562092,9.561107990851044,5.886098142883856e-11,0.2549636327127303,219.202802925074,11.977750801284902,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS350TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,350.0,317.3,1.994,1.994,1.0,72.0,9.62,47.4,9.03,38.8,0.003848,-0.14694,46.1,1.9364735581310404,9.628522903493739,2.2234172070043606e-10,0.31257102672062953,352.80624385808244,12.806009737555769,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS350TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,350.0,324.1,1.93452,,,72.0,9.62,47.4,9.03,38.8,0.0036555999999999997,-0.133194,44.49,1.8044752491239238,9.632000712168695,3.696854319394001e-11,0.3437481337254814,275.55507151872627,7.817338870094573,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS350UD-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,350.0,322.8,1.92,,,72.0,9.6,46.7,9.0,38.9,0.0042239999999999995,-0.131227,45.73,1.7978616632135607,9.610366821476443,4.9280419719362046e-11,0.2521036061154276,233.4558048386967,10.297926269292919,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS350UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,350.0,320.0,1.94,,,72.0,9.6,46.7,9.0,38.9,0.003936,-0.131227,47.3,1.8105890784240621,9.610062157668507,5.917235893167873e-11,0.24901093715277614,237.57380017313164,11.972376301111227,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS355TD-AN3,Hansol Technics Co Ltd,Multi-c-Si,0,355.0,321.9,1.994,1.994,1.0,72.0,9.65,47.8,9.06,39.2,0.00386,-0.14818,46.1,1.9546280364455728,9.65825442475021,2.281651906062633e-10,0.3048648021712287,356.40831556869824,13.012520585566406,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS355TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,355.0,328.9,1.93452,,,72.0,9.65,47.8,9.06,39.2,0.003667,-0.13431800000000002,44.49,1.8212949567607928,9.661659651385886,3.794694556464048e-11,0.33629555968934116,278.33183812256374,8.01740553028421,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS355UD-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,355.0,327.6,1.92,,,72.0,9.64,47.0,9.04,39.3,0.004241600000000001,-0.13207000000000002,45.73,1.8128192263600378,9.649603609638218,5.195982254125106e-11,0.23350668279676454,234.39149813330047,10.732987791273786,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS355UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,355.0,329.0,1.92,,,72.0,9.64,47.0,9.04,39.3,0.004434400000000001,-0.13301,44.32,1.8289384259599653,9.649239055196594,6.532605151414711e-11,0.22959787302528484,239.56167196908257,11.965178195609885,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS360TD-AN4,Hansol Technics Co Ltd,Mono-c-Si,0,360.0,333.6,1.93452,,,72.0,9.69,48.2,9.1,39.6,0.0036822,-0.13544200000000003,44.49,1.8380494323487353,9.70128182549029,3.8941675979318276e-11,0.328561334980214,282.20250258363154,8.206461162513076,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS360UD-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,360.0,332.3,1.92,,,72.0,9.67,47.4,9.07,39.7,0.0042548,-0.133194,45.73,1.8296518164945417,9.679237580461502,5.317352938161744e-11,0.22644631420156652,237.0464750728218,10.911293125743,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS360UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,360.0,333.8,1.92,,,72.0,9.67,47.4,9.07,39.7,0.0044482,-0.13414199999999998,44.32,1.845929286046022,9.678880606362391,6.684818777450869e-11,0.22250766655187518,242.2862867280255,12.144922672159625,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS365UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,365.0,339.5,1.92,,,72.0,9.95,47.1,9.49,38.5,0.004676499999999999,-0.12717,44.59,1.7589043142773797,9.950004550289329,2.334898523006809e-11,0.341794461387574,747415.7897900824,7.675070718194661,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS365UD-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,365.0,337.0,1.92,,,72.0,9.71,47.8,9.11,40.1,0.0042724,-0.13431800000000002,45.73,1.8464159992653064,9.718852618770494,5.440369067713977e-11,0.2192232514505219,240.45515288030293,11.07847052177292,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS365UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,365.0,338.5,1.92,,,72.0,9.71,47.8,9.11,40.1,0.0044666,-0.13527399999999998,44.32,1.8628506849200193,9.718503375946964,6.83910594995933e-11,0.21525964365428124,245.80486476612683,12.313451981981673,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS370UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,370.0,344.3,1.92,,,72.0,9.98,47.5,9.52,38.9,0.0046906,-0.12825000000000003,44.59,1.7753808838311806,9.980004531067637,2.396935024864403e-11,0.3348152421360475,737476.1958007404,7.877597444204882,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS370UD-AN1 {Blk},Hansol Technics Co Ltd,Mono-c-Si,0,370.0,341.8,1.92,,,72.0,9.74,48.2,9.14,40.5,0.0042856,-0.13544200000000003,45.73,1.8632399317568973,9.748501510400509,5.56274523899161e-11,0.21227058270154486,243.1939038606606,11.249913928738088,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS370UD-AN1 {Wht},Hansol Technics Co Ltd,Mono-c-Si,0,370.0,343.3,1.92,,,72.0,9.74,48.2,9.14,40.5,0.0044804,-0.136406,44.32,1.8798326802126126,9.748159606390711,6.992556166961068e-11,0.20827761546695397,248.61785853114623,12.48627031157594,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS370UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,370.0,346.5,1.929,,,72.0,9.83,47.5,9.28,39.9,0.0047184,-0.13205000000000003,43.36,1.7902509298110616,9.836316085596506,2.9086365321631916e-11,0.21945754264953982,341.55136666471907,6.573136615756657,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS375UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,375.0,349.0,1.92,,,72.0,10.01,47.9,9.55,39.3,0.0047047,-0.12933,44.59,1.7918584537405895,10.010004508876728,2.4595841066760252e-11,0.32788238479828735,727941.0740485301,8.076874499993028,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS375UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,375.0,351.3,1.929,,,72.0,9.91,47.7,9.36,40.1,0.0047568,-0.13260600000000003,43.36,1.7981020217395587,9.91602745240625,2.947327120713262e-11,0.21474997922677355,353.0799041242202,6.615441848316931,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS380UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,380.0,353.8,1.92,,,72.0,10.04,48.3,9.58,39.7,0.0047187999999999996,-0.13041,44.59,1.8083370098557117,10.040004483736642,2.522836275910057e-11,0.32099537042599,718794.0350027304,8.272980739966801,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS380UD-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,380.0,352.4,1.978,,,72.0,9.85,48.3,9.33,40.7,0.004137,-0.129444,46.73,1.7810954358753424,9.854973295610364,1.6270913346906588e-11,0.2168753357435826,429.53852747350516,5.548830875141958,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS380UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,380.0,356.1,1.929,,,72.0,9.98,47.9,9.43,40.3,0.0047904,-0.133162,43.36,1.8060080469336794,9.985771646542323,2.9854060344312634e-11,0.2103217799051046,363.6763568099734,6.6639852364303165,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS380UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,380.0,350.1,2.09,,,78.0,10.36,49.7,9.48,40.1,0.0043512,-0.13965700000000003,45.8,1.906910968023174,10.402162556689557,4.749141705351825e-11,0.40348441379500377,99.1424356713663,9.406259705656934,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS385UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,385.0,358.6,1.92,,,72.0,10.07,48.7,9.61,40.1,0.004732900000000001,-0.13149000000000002,44.59,1.8248165387677668,10.070004455670919,2.5866821623598772e-11,0.31415369025086065,710019.5064793141,8.465992524586639,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS385UD-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,385.0,357.2,1.978,,,72.0,9.93,48.5,9.41,40.9,0.0041706,-0.12998,46.73,1.7887741605769185,9.934719129892695,1.6486241637305204e-11,0.21226095647372073,446.6398175524826,5.590414154437827,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS385UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,385.0,360.9,1.929,,,72.0,10.05,48.1,9.5,40.5,0.004824,-0.13371800000000003,43.36,1.8139153444983778,10.055522567999434,3.0237237946777777e-11,0.20595868391188762,374.80476199225797,6.71227031198822,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS385UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,385.0,354.9,2.09,,,78.0,10.39,50.1,9.51,40.5,0.0043638,-0.14078100000000002,45.8,1.9240011379289041,10.431110089026179,4.8772065547795184e-11,0.3960676296825521,100.10055418357648,9.61558271878291,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS390UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,390.0,363.4,1.92,,,72.0,10.1,49.1,9.64,40.5,0.0047469999999999995,-0.13257000000000002,44.59,1.841297027746304,10.100004424706523,2.651112519703093e-11,0.3073568453213829,701602.6748188526,8.65598381388308,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS390UD-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,390.0,361.9,1.978,,,72.0,10.01,48.7,9.49,41.1,0.0042042,-0.13051600000000002,46.73,1.7964539714912917,10.014472138964804,1.6702819430120102e-11,0.20772403947363513,464.9492487684201,5.631774280437959,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS390UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,390.0,365.7,1.929,,,72.0,10.13,48.3,9.58,40.7,0.004862400000000001,-0.134274,43.36,1.8217724481055146,10.13525615482821,3.063215828835596e-11,0.2014705862261446,388.28709003911433,6.754167471350118,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS390UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,390.0,359.6,2.09,,,78.0,10.42,50.5,9.54,40.9,0.0043764,-0.141905,45.8,1.9410852805344123,10.460075584228253,5.006213112838051e-11,0.3887022923585431,101.06597321282575,9.820901573695371,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA395XA-CGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,372.1,1.94,,,54.0,13.69,36.8,12.81,30.9,0.0060236,-0.108928,43.2,1.3582987147425196,13.707027323656037,2.2870454397636068e-11,0.1283126617405746,103.16361989425806,-4.3822390255599055,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS 395 XA-CLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,377.0,1.32,,,54.0,13.7,37.0,12.81,30.8,0.00548,-0.08806,43.1,1.3207605135943623,13.722502194200821,9.095558921679866e-12,0.15977755299427934,97.27729043018948,10.531100263198438,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS395UD-AH2,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,368.2,1.92,,,72.0,10.13,49.5,9.67,40.9,0.004761100000000001,-0.13365000000000002,44.59,1.8577784836881044,10.13000439947119,2.71611893194637e-11,0.30060434226829286,692174.1020781011,8.84302859204254,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS395UD-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,366.7,1.978,,,72.0,10.09,48.9,9.57,41.3,0.004237800000000001,-0.131052,46.73,1.8041360423845318,10.094232178196242,1.6920945843915085e-11,0.203262367882518,484.60088734266685,5.673065700716265,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS395UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,370.5,1.929,,,72.0,10.21,48.5,9.66,40.9,0.0049008,-0.13483,43.36,1.8296316833329143,10.214997221578676,3.1029792695825434e-11,0.19705627549162827,402.61264507054966,6.795963338113102,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS395UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,364.3,2.09,,,78.0,10.45,50.9,9.57,41.3,0.004389,-0.14302900000000002,45.8,1.9581622225458566,10.489058821550392,5.136042424827779e-11,0.3813880867733151,102.03855066383966,10.022180476469421,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS395UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,395.0,371.0,2.09,,,78.0,9.48,52.0,8.8,44.9,0.0040764,-0.14456000000000002,42.54,1.992958657338782,9.485569711991417,4.261149435707066e-11,0.08912340154969745,151.69363360368723,10.386747694039197,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA400XA-CGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.78,37.0,12.89,31.1,0.0060631999999999995,-0.10951999999999999,43.2,1.3666450233663459,13.79704920044483,2.3453847375622117e-11,0.12527777342456603,101.25564126605941,-4.236065116767387,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS 400 XA-CLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,400.0,381.9,1.32,,,54.0,13.79,37.1,12.9,31.0,0.005516,-0.088298,43.1,1.3264849536743533,13.810951765568495,9.583303187032223e-12,0.1488325737992578,97.95838871511387,10.943728467052383,-0.32,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HS400UD-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,400.0,371.5,1.978,,,72.0,10.16,49.1,9.64,41.5,0.0042672000000000005,-0.131588,46.73,1.811867016149251,10.164021866053874,1.71346603281897e-11,0.1990604192080801,502.8645534397318,5.7199703660314745,-0.341,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HS400UD-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,400.0,375.3,1.929,,,72.0,10.29,48.7,9.74,41.1,0.0049391999999999995,-0.13538600000000003,43.36,1.837493525680181,10.294745628469501,3.143036899945255e-11,0.19271382992654962,417.86357911619086,6.837719048671741,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS400UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,400.0,369.1,2.09,,,78.0,10.48,51.3,9.6,41.7,0.0044016,-0.14415300000000003,45.8,1.9752358039667672,10.518059374692248,5.2669182463945324e-11,0.37412359262777656,103.01838420898139,10.219953469028802,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS400UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,400.0,375.8,2.09,,,78.0,9.55,52.2,8.87,45.1,0.0041065,-0.14511600000000002,42.54,2.0006550743429514,9.555308181752103,4.297015141165981e-11,0.08550471089527596,153.83233475362843,10.393619254782752,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA405XA-CGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.86,37.3,12.97,31.2,0.0060983999999999995,-0.11040799999999999,43.2,1.373946125531011,13.87841938322984,2.1916968860703714e-11,0.13909177107548273,104.66213390645206,-4.8087740893562545,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS 405 XA-CLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,405.0,386.8,1.32,,,54.0,13.87,37.2,12.98,31.2,0.005548,-0.088536,43.1,1.332235015687945,13.889450929107774,1.0090392625530771e-11,0.138141443060174,98.50541369106425,11.358802498159429,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS405UD-HH2,Hansol Technics Co Ltd,Mono-c-Si,0,405.0,376.3,1.978,,,72.0,10.24,49.3,9.72,41.7,0.0043008000000000005,-0.13212400000000002,46.73,1.8195528789050548,10.24379514468254,1.7355740484190648e-11,0.19473799780977585,525.4390234032755,5.761017331595298,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS405UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,405.0,373.8,2.09,,,78.0,10.51,51.7,9.63,42.1,0.0044142,-0.14527700000000002,45.8,1.9923023542652853,10.5470771204986,5.398552489453852e-11,0.36690908337945677,104.00523146740471,10.41387869482031,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS405UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,405.0,380.6,2.09,,,78.0,9.63,52.4,8.95,45.3,0.0041409,-0.14567200000000002,42.54,2.008270479342542,9.635046726752645,4.333240101339799e-11,0.08188874532030717,156.2574435614277,10.391517270572498,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA410XA-CGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.94,37.5,13.05,31.4,0.0061335999999999995,-0.11099999999999999,43.2,1.3817917467582346,13.957859887498392,2.2259885426217626e-11,0.13618368070165343,106.29409154025964,-4.7344489627305055,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS410UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,410.0,378.6,2.09,,,78.0,10.54,52.1,9.64,42.5,0.0044268,-0.14640100000000003,45.8,2.0115379393486705,10.578049067457167,5.6741866917746305e-11,0.3595931989909025,99.61117572709264,10.840616186615756,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS410UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,410.0,385.4,2.09,,,78.0,9.7,52.6,9.02,45.5,0.004170999999999999,-0.14622800000000002,42.54,2.015975823381841,9.70479746590926,4.3696187589388505e-11,0.07838287470115612,158.48239505743138,10.399279931843527,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA415XA-CGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,415.0,391.4,1.94,,,54.0,14.02,37.8,13.13,31.6,0.0061687999999999995,-0.111888,43.2,1.3913957349896777,14.03812977555439,2.1776444279563256e-11,0.14100594543139544,109.0418001302304,-4.950119332900352,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS415UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,415.0,390.2,2.09,,,78.0,9.77,52.8,9.09,45.7,0.004201099999999999,-0.14678400000000003,42.54,2.023684943509091,9.774554052221253,4.4062295998008745e-11,0.0749295589967268,160.74954023922243,10.407388360005353,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA420AA-DGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,420.0,399.1,1.94,,,54.0,14.07,38.1,13.33,31.5,0.0063315,-0.093345,43.1,1.3154524741271607,14.081768798434826,3.669835692175513e-12,0.18457344637348808,220.6638519720332,-0.6986895626821872,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA420AA-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,420.0,398.1,1.94,,,54.0,14.11,38.0,13.34,31.5,0.0049385,-0.09043999999999999,43.7,1.304323346821083,14.12443829272949,3.094065501131645e-12,0.17828783894303762,174.23399441652865,0.9443393746553765,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA420XA-CGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,420.0,396.3,1.94,,,54.0,14.1,38.0,13.22,31.8,0.0062039999999999994,-0.11248,43.2,1.3987093671394737,14.116928280531916,2.1907466010786267e-11,0.138181118457225,115.09460599712344,-4.951706941135746,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HS420UE-AN1,Hansol Technics Co Ltd,Mono-c-Si,0,420.0,388.1,2.09,,,78.0,10.61,52.9,9.71,43.3,0.0044562000000000004,-0.14864900000000003,45.8,2.0455807699325383,10.646016758245446,5.946928358250664e-11,0.34504793866958744,101.64597919901979,11.200651578313128,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS420UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,420.0,395.0,2.09,,,78.0,9.84,53.0,9.16,45.9,0.0042312,-0.14734000000000003,42.54,2.0313977635216083,9.844316395288791,4.44307097046706e-11,0.07152762682011471,163.06010080159587,10.415830435521183,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA425AA-DGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,425.0,403.9,1.94,,,54.0,14.15,38.3,13.41,31.7,0.006367500000000001,-0.093835,43.1,1.32285998519635,14.161368785551115,3.732492246142019e-12,0.1815503553284724,225.96411201653274,-0.6072062164678105,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA425AA-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,425.0,402.9,1.94,,,54.0,14.18,38.2,13.41,31.7,0.004963,-0.09091600000000001,43.7,1.3116856136940014,14.194031681103347,3.144687618224033e-12,0.1754413062303748,177.29577141744332,1.0375970624615785,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS425UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,425.0,399.9,2.09,,,78.0,9.9,53.2,9.22,46.1,0.0042569999999999995,-0.14789600000000003,42.54,2.0318594610229153,9.90421844212353,4.0765593342465563e-11,0.07002789059331946,164.34411076331583,9.597198965109493,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA430AA-DGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,430.0,408.8,1.94,,,54.0,14.23,38.5,13.49,31.9,0.0064035,-0.094325,43.1,1.3302667312468843,14.240977987910167,3.79555894155999e-12,0.178563741247382,231.45972316955206,-0.5168101672262381,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA430AA-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,430.0,407.8,1.94,,,54.0,14.25,38.4,13.48,31.9,0.004987500000000001,-0.091392,43.7,1.3190469962083544,14.263633426161348,3.1955973919854777e-12,0.17262499927509486,180.43199220715903,1.1297018209407823,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS430UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,430.0,404.7,2.09,,,78.0,9.97,53.4,9.29,46.3,0.0042871,-0.14845200000000003,42.54,2.0469143975979414,9.973862537544905,4.517135956352908e-11,0.06490759398953155,167.53978631051962,10.442330128747555,-0.352,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA435AA-DGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,435.0,413.7,1.94,,,54.0,14.31,38.7,13.57,32.1,0.0064395,-0.094815,43.1,1.8479681865515787,14.310049111400588,9.990006589352596e-14,2.34837141809491,815275.7454851891,99.99999371696501,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA435AA-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,435.0,412.6,1.94,,,54.0,14.32,38.6,13.56,32.1,0.005012,-0.09186799999999999,43.7,1.3259724306100815,14.332427125796599,3.218704798565575e-12,0.1698507976886702,195.7221210863324,1.144676356721577,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HS435UE-JH2,Hansol Technics Co Ltd,Mono-c-Si,0,435.0,409.5,2.09,,,78.0,10.04,53.6,9.36,46.5,0.004317199999999999,-0.14900800000000003,42.54,2.03770092183115,10.043930279302646,3.6655456170917034e-11,0.06578149483102111,168.0405283198323,8.535450682371978,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA440AA-DGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,440.0,418.5,1.94,,,54.0,14.39,38.9,13.65,32.2,0.0064754999999999995,-0.095305,43.1,1.3431002571334336,14.400456538319176,3.7604466934616844e-12,0.1810404824579878,249.14292558254655,-0.6880225886291299,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA440AA-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,440.0,417.5,1.94,,,54.0,14.39,38.8,13.63,32.3,0.0050365,-0.09234399999999998,43.7,1.3333314566903969,14.402059834903762,3.269860069199559e-12,0.1670956886384904,199.38141655376123,1.2348730590494592,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA525XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,525.0,495.0,2.56,,,72.0,13.64,49.14,12.75,41.16,0.005319600000000001,-0.1199016,43.2,1.778957915473936,13.659831890741467,1.3385633679623612e-11,0.18689271798738002,128.5412830276396,11.30055898633395,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA530XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,530.0,499.5,2.56,,,72.0,13.72,49.3,12.83,41.3,0.0060368,-0.145928,43.2,1.8180481715324739,13.738327987342657,2.235904361774668e-11,0.18004156841659394,134.77586386459478,-4.572769553045986,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA530XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,530.0,499.8,2.56,,,72.0,13.73,49.31,12.83,41.32,0.0053547,-0.1203164,43.2,1.7857646222216939,13.750084393392616,1.3604933001434696e-11,0.184708112481534,126.26930479931924,11.38989710838697,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA530XD-GNEA0,Hansol Technics Co Ltd,Mono-c-Si,1,530.0,500.1,2.56,,,72.0,13.65,49.4,12.91,41.1,0.007917,-0.125476,43.1,1.8064673015290091,13.659625899526736,1.7937787312257725e-11,0.2075319981302047,294.2906049593908,9.14100600677269,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA535XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,535.0,504.3,2.56,,,72.0,13.7,49.5,12.9,41.5,0.006027999999999999,-0.14651999999999998,43.2,1.819852387509457,13.712460074303884,2.071369835415015e-11,0.17889812279801656,196.70061625337433,-5.17726668097779,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA535XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,535.0,504.6,2.56,,,72.0,13.78,49.44,12.9,41.46,0.0053742,-0.1206336,43.2,1.7895824356005081,13.798387366129084,1.349591296257558e-11,0.18193889939075925,136.35003640722152,11.27588215727621,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA535XD-GNEA0,Hansol Technics Co Ltd,Mono-c-Si,1,535.0,505.0,2.56,,,72.0,13.71,49.6,12.96,41.3,0.0079518,-0.125984,43.1,1.8149588345979335,13.720078418356792,1.8326615163524308e-11,0.20445244729265222,278.1233098821654,9.29540374097511,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA540XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,540.0,509.2,2.56,,,72.0,13.86,49.6,12.97,41.6,0.0060983999999999995,-0.146816,43.2,1.8295840164895978,13.877557321988753,2.2762280123504526e-11,0.17506998387227873,138.20273891208012,-4.515253507455236,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA540XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,540.0,509.4,2.56,,,72.0,13.85,49.61,12.97,41.65,0.0054015,-0.1210484,43.2,1.7964485483542825,13.867824823535909,1.3718057480120965e-11,0.1774894034842182,137.91038327133916,11.376717576583431,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA540XD-GNEA0,Hansol Technics Co Ltd,Mono-c-Si,1,540.0,509.8,2.56,,,72.0,13.77,49.8,13.02,41.5,0.0079866,-0.126492,43.1,1.8227910326273244,13.77979339344974,1.8553218302240063e-11,0.20145157166641417,283.25096620597145,9.36518533008313,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA545XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,545.0,514.0,2.56,,,72.0,13.93,49.8,13.04,41.8,0.0061292,-0.14740799999999998,43.2,1.8373825942112085,13.947118979403355,2.3027565409692244e-11,0.17208874752495867,140.03149400697393,-4.465576969963724,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HA545XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,545.0,514.3,2.56,,,72.0,13.92,49.76,13.04,41.81,0.005428799999999999,-0.12141439999999999,43.2,1.802309439034315,13.937373953662707,1.3882882120955863e-11,0.17417611799132166,139.54978815182463,11.438003313473944,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA545XD-GNEA0,Hansol Technics Co Ltd,Mono-c-Si,1,545.0,514.6,2.56,,,72.0,13.83,51.8,13.08,41.7,0.008021400000000001,-0.131572,43.1,1.8634700151059087,13.841353982820856,1.1610798534558284e-11,0.3375711529180416,411.18690887254667,5.208083715377042,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA550XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,550.0,518.8,2.56,,,72.0,14.0,49.9,13.11,42.0,0.0061600000000000005,-0.147704,43.2,1.8434186208727996,14.016044856373147,2.3959210086092186e-11,0.16143789490308047,140.86324435632167,-4.197192010480979,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA550XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,550.0,519.1,2.56,,,72.0,14.02,49.91,13.1,41.97,0.005467799999999999,-0.1217804,43.2,1.810704517066173,14.039276043239065,1.45834524068559e-11,0.1702155031775858,123.80244897213224,11.832566960364252,-0.329,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HA550XD-GNEA0,Hansol Technics Co Ltd,Mono-c-Si,1,550.0,519.5,2.56,,,72.0,13.89,50.2,13.13,41.9,0.0080562,-0.127508,43.1,1.8391146515679708,13.899937449338479,1.9179778433605873e-11,0.19547387224243926,273.22223209227576,9.585783119029951,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA555XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,555.0,523.6,2.56,,,72.0,14.07,50.1,13.18,42.1,0.006190800000000001,-0.14829599999999998,43.2,1.8489225494596921,14.086385378943328,2.3436520008894346e-11,0.16728063882332941,143.64261005816914,-4.40885800977868,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA555XD-GLEA0,Hansol Technics Co Ltd,Mono-c-Si,0,555.0,523.9,2.56,,,72.0,14.07,50.03,13.17,42.15,0.0054873000000000005,-0.12207319999999999,43.2,1.8151906578293642,14.087289402502341,1.4692989090933076e-11,0.16334226024817225,132.92683514104527,11.860640615479461,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA560AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,560.0,532.1,2.56,,,72.0,14.11,50.7,13.34,42.0,0.0052207,-0.121173,43.0,1.7419287565762192,14.124450383644815,3.1829718962978833e-12,0.23985277441742459,234.20296175659647,0.7252866866922225,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA560XD-GGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,560.0,528.5,2.56,,,72.0,14.14,50.2,13.25,42.3,0.0062216,-0.148592,43.2,1.8549571920742298,14.155341626920412,2.437709356982237e-11,0.15676952304899283,144.4906120879602,-4.142357772561173,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HA565AD-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,565.0,537.1,2.56,,,72.0,14.23,50.6,13.48,41.9,0.0064035,-0.12397,43.1,1.7484199093087638,14.241897027016998,3.796851820830245e-12,0.2368483853220864,283.293677041572,-0.5110044463227119,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA565AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,565.0,537.0,2.56,,,72.0,14.17,50.9,13.39,42.2,0.005242899999999999,-0.121651,43.0,1.7498597751993374,14.184974777543703,3.25118571255126e-12,0.23685775858866273,224.12850135562718,0.8692007798019963,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA570AD-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,570.0,542.0,2.56,,,72.0,14.31,50.7,13.55,42.1,0.0064395,-0.124215,43.1,1.7545348539890846,14.32216074402442,3.986401919553647e-12,0.22613323335264604,266.0993782611494,-0.15319937254843688,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA570AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,570.0,541.8,2.56,,,72.0,14.23,51.1,13.45,42.4,0.0052651,-0.122129,43.0,1.7572094722485994,14.24463527939972,3.291368316911901e-12,0.2338963813340526,227.41933549680093,0.9355846311541071,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA570-AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,570.0,541.8,2.56,,,72.0,14.23,51.1,13.45,42.4,0.0052651,-0.122129,43.0,1.7572094722485994,14.24463527939972,3.291368316911901e-12,0.2338963813340526,227.41933549680093,0.9355846311541071,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA575AD-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,575.0,546.8,2.56,,,72.0,14.39,50.9,13.62,42.2,0.0064754999999999995,-0.124705,43.1,1.7604785706039525,14.402893199570217,3.943513387231344e-12,0.23128036501808694,258.1302217532027,-0.28701200276551464,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA575AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,575.0,546.7,2.56,,,72.0,14.29,51.3,13.5,42.6,0.0052873,-0.122607,43.0,1.7651418169430533,14.305136527471795,3.3609866441666883e-12,0.23094784399360496,218.03182402826286,1.0777034563617454,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA580AD-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,580.0,551.7,2.56,,,72.0,14.47,51.0,13.69,42.4,0.006511500000000001,-0.12495,43.1,1.7665936417144827,14.483089821325263,4.138554738670696e-12,0.22070416468563014,243.97500875971036,0.06828682844284706,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA580AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,580.0,551.6,2.56,,,72.0,14.35,51.5,13.56,42.8,0.005309499999999999,-0.123085,43.0,1.772490639671126,14.364796888152387,3.401773626139784e-12,0.22803739131153503,221.1503206942208,1.1426817622303624,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA585AD-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,585.0,556.5,2.56,,,72.0,14.55,51.2,13.76,42.5,0.0065475,-0.12544,43.1,1.7725350689028465,14.563844057485658,4.09373217308099e-12,0.2258266349977697,237.3420904871206,-0.06590716705807184,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HA585-AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,585.0,545.5,2.56,,,72.0,14.41,51.7,13.61,43.0,0.01763784,-0.16164005,43.1,2.1961134974551713,14.413828631284451,8.55416920014762e-10,0.15847147397167835,596.446803527744,19.724281026864883,-0.40828,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA590AD-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,590.0,561.4,2.56,,,72.0,14.63,51.3,13.83,42.7,0.0065835,-0.125685,43.1,1.7786502500392587,14.643974608520978,4.294335995127757e-12,0.21538598187426702,225.48731256590537,0.28691699717187996,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA590-AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,590.0,550.3,2.56,,,72.0,14.47,51.9,13.66,43.2,0.017711280000000003,-0.16226535,43.1,2.206113742763498,14.474202789436228,8.723013683655226e-10,0.15545762595860296,535.2332561847285,19.877277434498968,-0.40828,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HA590ZB-GGFA0,Hansol Technics Co Ltd,Mono-c-Si,0,590.0,555.5,2.81,,,60.0,18.3,41.2,17.21,34.3,0.008601000000000001,-0.11906800000000001,43.4,1.5206342168984175,18.319482352200133,3.0749275821444896e-11,0.1261533478525915,118.49730746000847,-2.071731284908604,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA595-AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,595.0,555.1,2.56,,,72.0,14.53,52.1,13.72,43.4,0.017784719999999997,-0.16289065,43.1,2.2152740914883013,14.534006148295338,8.822536059998869e-10,0.15258961854757444,553.4313345655609,19.9474798951833,-0.40828,N,2025.7.3,6/23/2025,2.0,first_pass +Hansol Technics Co Ltd HA595ZB-GGFA0,Hansol Technics Co Ltd,Mono-c-Si,0,595.0,560.3,2.81,,,60.0,18.34,41.4,17.25,34.5,0.0086198,-0.11964599999999999,43.4,1.5286819685912103,18.35908798218426,3.1184593314694807e-11,0.12426226496263286,119.39292117434624,-1.97754867178545,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA600-AD-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,600.0,559.9,2.56,,,72.0,14.59,52.3,13.77,43.6,0.017858159999999998,-0.16351595,43.1,2.2252746016859324,14.59435746586109,8.994287226597028e-10,0.14962129793351203,500.9736169357357,20.098483576376182,-0.40828,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA600ZB-GGFA0,Hansol Technics Co Ltd,Mono-c-Si,0,600.0,565.1,2.81,,,60.0,18.39,41.6,17.3,34.7,0.0086433,-0.120224,43.4,1.5367024018521869,18.408667191995253,3.1625286869143315e-11,0.12231585557906371,120.49956936918102,-1.887909353583001,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA605ZB-GGFA0,Hansol Technics Co Ltd,Mono-c-Si,0,605.0,569.9,2.81,,,60.0,18.43,41.8,17.34,34.9,0.008662099999999999,-0.12080199999999999,43.4,1.5447476905925492,18.44828283410148,3.206352752123636e-11,0.12044449350196426,121.41400044436556,-1.795845301301945,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA610AE-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,610.0,579.9,2.77,,,78.0,14.03,55.3,13.38,45.6,0.0063135000000000005,-0.135485,43.1,1.9013857966275494,14.033809540543503,3.269368059191804e-12,0.2789101816702262,1027.1868015467924,-1.6495551152094612,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA610-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,610.0,581.4,2.77,,,78.0,14.11,55.1,13.35,45.7,0.006067299999999999,-0.12507700000000002,43.5,1.8468791012435068,14.12496534583852,1.5358017464471867e-12,0.2639447016498547,248.85891438435232,-0.24198446501573573,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA610ZB-GGFA0,Hansol Technics Co Ltd,Mono-c-Si,0,610.0,574.8,2.81,,,60.0,18.48,42.0,17.38,35.1,0.008685600000000002,-0.12137999999999999,43.4,1.553209471062034,18.498542408918333,3.273732382285182e-11,0.11848439302886596,118.0856069483094,-1.6497681896032172,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hansol Technics Co Ltd HA615AE-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,615.0,584.7,2.77,,,78.0,14.11,55.4,13.44,45.8,0.0063495,-0.13573000000000002,43.1,1.9081451168784884,14.115385610716908,3.453014329634256e-12,0.267889906860462,701.8566412966572,-1.2440428341740015,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA615-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,615.0,586.2,2.77,,,78.0,14.16,55.3,13.4,45.9,0.006088799999999999,-0.12553099999999998,43.5,1.8540519259386121,14.17467632110476,1.5531795950203548e-12,0.26107969197871284,251.89476375498577,-0.17819925219892477,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA620AE-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,620.0,589.6,2.77,,,78.0,14.19,55.6,13.5,45.9,0.0063855,-0.13622,43.1,1.914758722846184,14.196868742149318,3.4537806083960757e-12,0.27285615710171995,563.6881951769086,-1.2836906865418656,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA620-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,620.0,591.1,2.77,,,78.0,14.21,55.5,13.45,46.1,0.0061103,-0.125985,43.5,1.8612241488204848,14.224391395132603,1.5706264129674e-12,0.258236425739018,254.98150592153812,-0.11495362221391843,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA625AE-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,625.0,594.4,2.77,,,78.0,14.27,55.7,13.56,46.1,0.006421499999999999,-0.136465,43.1,1.9215250733296145,14.278294149670534,3.646167672984945e-12,0.2619583176121862,450.6966142148243,-0.8801454576073551,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA625-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,625.0,596.0,2.77,,,78.0,14.26,55.7,13.5,46.3,0.0061318,-0.12643900000000002,43.5,1.8683958023337326,14.2741105392612,1.588142321187681e-12,0.25541465096736493,258.120037416967,-0.052236182073625965,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA630AE-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,630.0,599.3,2.77,,,78.0,14.35,55.9,13.62,46.3,0.006457499999999999,-0.13695500000000002,43.1,1.9301123086186358,14.359697794828644,3.7553213126819775e-12,0.2585445064042989,382.57291207843764,-0.6786750991966924,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA630-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,630.0,600.8,2.77,,,78.0,14.31,55.9,13.55,46.5,0.0061533,-0.126893,43.5,1.8755668663398797,14.323833681714119,1.6057261777168988e-12,0.2526141289458489,261.31208280799814,0.009954529053664413,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA635AE-NGEA0,Hansol Technics Co Ltd,Mono-c-Si,0,635.0,604.2,2.77,,,78.0,14.43,56.0,13.68,46.4,0.0064935,-0.13720000000000002,43.1,1.9349081350355437,14.441097861699213,3.847580374814371e-12,0.25612958726010254,333.03261941818187,-0.5197672277851582,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA635-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,635.0,605.7,2.77,,,78.0,14.36,56.1,13.6,46.7,0.006174799999999999,-0.12734700000000002,43.5,1.8827373451929286,14.373560773152953,1.6233774342551942e-12,0.2498346198461521,264.5590375515642,0.07162519518359287,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA640-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,640.0,610.6,2.77,,,78.0,14.41,56.3,13.65,46.9,0.0061963,-0.127801,43.5,1.8899072871075222,14.423291797614446,1.6410966237876743e-12,0.2470758808710625,267.86169558168245,0.13278775326342726,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA645-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,645.0,615.5,2.77,,,78.0,14.46,56.5,13.7,47.1,0.0062178,-0.128255,43.5,1.8970766325643675,14.473026658487957,1.6588816462653262e-12,0.24433768940814157,271.2225084010615,0.19343981308173838,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hansol Technics Co Ltd HA650-AE-NNEA0,Hansol Technics Co Ltd,Mono-c-Si,0,650.0,620.3,2.77,,,78.0,14.51,56.7,13.75,47.3,0.0062393,-0.12870900000000002,43.5,1.9042454655834338,14.522765367512834,1.6767339400584473e-12,0.24161980420316018,274.6417882059288,0.25359772545637094,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M155,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,155.0,138.1,1.2766400000000002,1.58,0.808,72.0,4.9,43.5,4.38,35.4,0.0016660000000000002,-0.14268,47.1,1.8300899760169722,4.924340402674093,2.1700540635861483e-10,0.5998527879328684,120.75719554059697,12.568213846866742,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M160,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,160.0,142.7,1.2766400000000002,1.58,0.808,72.0,5.0,43.5,4.5,35.6,0.0017000000000000001,-0.14268,47.1,1.8289232334427403,5.02020703305184,2.1977773367576447e-10,0.5373560115202155,132.96262486728384,12.478473525390797,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M160B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,160.0,144.1,1.2766400000000002,1.58,0.808,72.0,5.0,43.5,4.5,35.6,0.00205,-0.14094,45.9,1.8127113727342612,5.020645117776102,1.7759103924252097e-10,0.5450054418423893,131.99378762208093,11.854659108049285,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M165,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,165.0,147.2,1.2766400000000002,1.58,0.808,72.0,5.1,44.0,4.61,35.8,0.001734,-0.14432,47.1,1.8388012420938251,5.120829586652795,1.9523207185239287e-10,0.5882022196625355,144.01780918040762,11.21469687639444,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M165B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,165.0,148.7,1.2766400000000002,1.58,0.808,72.0,5.1,44.0,4.61,35.8,0.002091,-0.14256,45.9,1.8225938752068127,5.1212645315933845,1.5774454894708164e-10,0.5956261080923492,142.85258224154092,10.596697450221802,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-P165,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,165.0,145.5,1.2766400000000002,1.58,0.808,72.0,5.14,43.7,4.65,35.5,0.000257,-0.14858000000000002,47.7,1.8379133605970617,5.160743423100719,2.2934556338380135e-10,0.5876883758084688,145.62294640679002,8.947422307917742,-0.4799,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M170,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,170.0,151.8,1.2766400000000002,1.58,0.808,72.0,5.12,44.5,4.74,35.9,0.0017408000000000002,-0.14596,47.1,1.8259496551109264,5.131780919428582,1.2974524033368524e-10,0.674650195958896,293.20370438490767,7.493634879055477,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M170B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,170.0,153.3,1.2766400000000002,1.58,0.808,72.0,5.12,44.5,4.74,35.9,0.0020992000000000003,-0.14418,45.9,1.8101206144504272,5.132107260970704,1.0479406001519533e-10,0.6816173709543509,288.24695570656417,6.891761888987986,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-P170,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,170.0,150.0,1.2766400000000002,1.58,0.808,72.0,5.17,44.1,4.78,35.5,0.0002585,-0.14994000000000002,47.7,1.8223014616948392,5.182544496840253,1.5525807956129736e-10,0.6750958969340323,278.2292571522629,5.459123518191065,-0.4799,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P170,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,170.0,150.4,1.494,1.494,1.0,54.0,7.54,32.2,6.47,26.3,0.0029406000000000002,-0.104328,47.0,1.4314920252467915,7.593124640348163,1.137605770795731e-09,0.24946946706660114,35.40729648160313,25.911961862948882,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M175,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,175.0,156.4,1.2766400000000002,1.58,0.808,72.0,5.17,44.8,4.86,36.0,0.0017578000000000001,-0.146944,47.1,1.8195064725562324,5.174139933055776,1.0383409848159346e-10,0.708189525560492,884.3960500963314,5.444610498259885,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M175B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,175.0,158.0,1.2766400000000002,1.58,0.808,72.0,5.17,44.8,4.86,36.0,0.0021197000000000004,-0.145152,45.9,1.8038595125723071,5.1744021450776065,8.382588081334698e-11,0.7148636093221574,839.5555503965577,4.849116053680916,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M175L,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,175.0,156.4,1.2766400000000002,1.58,0.808,72.0,5.17,44.8,4.86,36.0,0.0017578000000000001,-0.146944,47.1,1.8195064725562324,5.174139933055776,1.0383409848159346e-10,0.708189525560492,884.3960500963314,5.444610498259885,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M175L-B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,175.0,158.0,1.2766400000000002,1.58,0.808,72.0,5.17,44.8,4.86,36.0,0.0021197000000000004,-0.145152,45.9,1.8038595125723071,5.1744021450776065,8.382588081334698e-11,0.7148636093221574,839.5555503965577,4.849116053680916,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-P175,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,175.0,154.5,1.2766400000000002,1.58,0.808,72.0,5.2,44.5,4.9,35.7,0.00026000000000000003,-0.15130000000000002,47.7,1.8170024206498827,5.202598526538867,1.1949040232430394e-10,0.7078380403020347,1416.4792488573305,3.1482582432763646,-0.4799,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P175,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,175.0,155.0,1.494,1.494,1.0,54.0,7.64,32.3,6.63,26.4,0.0029796,-0.104652,47.0,1.4258659471361659,7.6879456262415236,9.9712978474488e-10,0.24698187465206922,39.35586576713017,24.401120302436155,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M180,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,180.0,161.0,1.2766400000000002,1.58,0.808,72.0,5.2,45.0,5.0,36.0,0.0017680000000000003,-0.1476,47.1,1.8301961352018679,5.200224823104397,1.0902459569995674e-10,0.6028805008904436,13944.231701755818,5.78153166070867,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M180B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,180.0,162.6,1.2766400000000002,1.58,0.808,72.0,5.2,45.0,5.0,36.0,0.002132,-0.1458,45.9,1.813825572715544,5.200228474939133,8.73272040822532e-11,0.6135951714961324,13965.210838356139,5.116951969702881,-0.434,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M180L,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,180.0,161.0,1.2766400000000002,1.58,0.808,72.0,5.2,45.0,5.0,36.0,0.0017680000000000003,-0.1476,47.1,1.8301961352018679,5.200224823104397,1.0902459569995674e-10,0.6028805008904436,13944.231701755818,5.78153166070867,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M180L-B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,180.0,162.6,1.2766400000000002,1.58,0.808,72.0,5.2,45.0,5.0,36.0,0.002132,-0.1458,45.9,1.813825572715544,5.200228474939133,8.73272040822532e-11,0.6135951714961324,13965.210838356139,5.116951969702881,-0.434,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M180,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,180.0,159.4,1.494,1.494,1.0,54.0,7.78,32.6,6.84,26.3,0.003112,-0.10692800000000001,46.7,1.4289988976681567,7.831704976165504,8.807898842143912e-10,0.3046127584498335,45.83480369021665,21.394964199793023,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M180B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,180.0,159.4,1.494,1.494,1.0,54.0,7.78,32.6,6.84,26.3,0.003112,-0.10692800000000001,46.7,1.4289988976681567,7.831704976165504,8.807898842143912e-10,0.3046127584498335,45.83480369021665,21.394964199793023,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P180,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,180.0,159.5,1.494,1.494,1.0,54.0,7.72,32.4,6.8,26.5,0.0030108,-0.104976,47.0,1.4172592323946689,7.760616844668556,8.333763617376555e-10,0.24589717651607002,46.73741468371295,22.44948303152214,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M185,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,185.0,165.6,1.2766400000000002,1.58,0.808,72.0,5.23,45.3,5.12,36.1,0.0017782000000000004,-0.148584,47.1,1.8539717503791098,5.230143863423852,1.278451811594077e-10,0.39029111839229735,14188.638707350943,7.094133682609144,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M185B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,185.0,167.2,1.2766400000000002,1.58,0.808,72.0,5.23,45.3,5.12,36.1,0.0021443000000000005,-0.14677199999999999,45.9,1.8377296367379579,5.230148041085334,1.0301462257804594e-10,0.40263457107122874,14224.307378869746,6.473703831825438,-0.434,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M185L,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,185.0,165.6,1.2766400000000002,1.58,0.808,72.0,5.23,45.3,5.12,36.1,0.0017782000000000004,-0.148584,47.1,1.8539717503791098,5.230143863423852,1.278451811594077e-10,0.39029111839229735,14188.638707350943,7.094133682609144,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M185L-B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,185.0,167.2,1.2766400000000002,1.58,0.808,72.0,5.23,45.3,5.12,36.1,0.0021443000000000005,-0.14677199999999999,45.9,1.8377296367379579,5.230148041085334,1.0301462257804594e-10,0.40263457107122874,14224.307378869746,6.473703831825438,-0.434,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M185,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,185.0,164.0,1.494,1.494,1.0,54.0,7.86,32.7,7.0,26.4,0.003144,-0.107256,46.7,1.4227186436616444,7.903111333834515,7.618854097010584e-10,0.3012731513940793,54.9277170625995,19.833482680449865,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M185B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,185.0,164.0,1.494,1.494,1.0,54.0,7.86,32.7,7.0,26.4,0.003144,-0.107256,46.7,1.4227186436616444,7.903111333834515,7.618854097010584e-10,0.3012731513940793,54.9277170625995,19.833482680449865,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P185,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,185.0,164.0,1.494,1.494,1.0,54.0,7.8,32.5,6.96,26.6,0.003042,-0.1053,47.0,1.4108584463076,7.833951126324987,7.183691574744495e-10,0.24401419659073706,56.060315351950514,20.83819220509356,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M190,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,190.0,170.2,1.2766400000000002,1.58,0.808,72.0,5.78,44.8,5.33,35.8,0.0019652000000000003,-0.146944,47.1,1.8320500368472479,5.7970502746585915,1.3437588692320294e-10,0.6770886434439384,229.53135170998436,6.762000277576345,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M190B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,190.0,171.8,1.2766400000000002,1.58,0.808,72.0,5.78,44.8,5.33,35.8,0.0023698000000000005,-0.145152,45.9,1.8161888012638672,5.797470816769072,1.0848592212816854e-10,0.6832558081293708,226.04660184479047,6.159501475629448,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M190L,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,190.0,170.2,1.2766400000000002,1.58,0.808,72.0,5.78,44.8,5.33,35.8,0.0019652000000000003,-0.146944,47.1,1.8320500368472479,5.7970502746585915,1.3437588692320294e-10,0.6770886434439384,229.53135170998436,6.762000277576345,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF160-24-M190L-B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,190.0,171.8,1.2766400000000002,1.58,0.808,72.0,5.78,44.8,5.33,35.8,0.0023698000000000005,-0.145152,45.9,1.8161888012638672,5.797470816769072,1.0848592212816854e-10,0.6832558081293708,226.04660184479047,6.159501475629448,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M190,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,190.0,168.5,1.494,1.494,1.0,54.0,7.93,32.8,7.17,26.5,0.003172,-0.10758399999999999,46.7,1.414947795095771,7.962705559476217,6.429787384235753e-10,0.2984333116938635,72.36006369239196,18.060652747712094,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M190B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,190.0,168.5,1.494,1.494,1.0,54.0,7.93,32.8,7.17,26.5,0.003172,-0.10758399999999999,46.7,1.414947795095771,7.962705559476217,6.429787384235753e-10,0.2984333116938635,72.36006369239196,18.060652747712094,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P190,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,190.0,168.6,1.494,1.494,1.0,54.0,7.98,32.6,7.12,26.7,0.0031122000000000003,-0.10562400000000001,47.0,1.4158680812257107,8.014346249016151,7.428488136766216e-10,0.23618444805275826,54.87504641686119,20.943554265260214,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M195,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,195.0,173.1,1.494,1.494,1.0,54.0,8.12,32.9,7.33,26.6,0.003248,-0.10791200000000001,46.7,1.421219082807385,8.154280988571202,6.783593157280589e-10,0.28900729385008966,68.45600198616317,18.352699543573852,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M195B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,195.0,173.1,1.494,1.494,1.0,54.0,8.12,32.9,7.33,26.6,0.003248,-0.10791200000000001,46.7,1.421219082807385,8.154280988571202,6.783593157280589e-10,0.28900729385008966,68.45600198616317,18.352699543573852,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P195,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,195.0,173.1,1.494,1.494,1.0,54.0,8.06,32.7,7.28,26.8,0.0031434,-0.10594800000000001,47.0,1.4103619763380655,8.087764516077256,6.483998741899367e-10,0.23413136319321318,67.9680101950647,19.47826155899082,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M200,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,200.0,177.6,1.494,1.494,1.0,54.0,8.19,33.0,7.49,26.7,0.0032760000000000003,-0.10824,46.7,1.4155110946600706,8.215045826821996,5.898925455070832e-10,0.28592620512984646,93.49804540038227,16.894065203605514,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M200B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,200.0,177.6,1.494,1.494,1.0,54.0,8.19,33.0,7.49,26.7,0.0032760000000000003,-0.10824,46.7,1.4155110946600706,8.215045826821996,5.898925455070832e-10,0.28592620512984646,93.49804540038227,16.894065203605514,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P200,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,200.0,177.7,1.494,1.494,1.0,54.0,8.24,32.8,7.44,26.9,0.0032136,-0.10627199999999999,47.0,1.4155415378308178,8.268231169241865,6.720219777287552e-10,0.22676708105522964,66.18786690888754,19.612344808071178,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M200,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,200.0,179.9,1.652,1.652,1.0,60.0,7.5,36.2,6.76,29.6,0.0027749999999999997,-0.12271800000000002,45.4,1.5246260003612562,7.529714931499878,3.44150445633521e-10,0.3014508109840087,76.08569353339877,9.14587758222652,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M200B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,200.0,178.9,1.652,1.652,1.0,60.0,7.8,35.2,7.17,27.9,0.0017159999999999999,-0.11932800000000002,46.1,1.4293374316682619,7.827964448424093,1.5202412385135943e-10,0.4336006456153799,120.94231797670342,1.9868296286968423,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P200,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,200.0,180.0,1.652,1.652,1.0,60.0,7.52,36.0,6.78,29.5,0.004136,-0.11699999999999999,45.3,1.5404656798247636,7.547518792841424,5.019665721547649e-10,0.28091183827207966,76.76416437607418,17.148253796650266,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P200B,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,200.0,178.9,1.652,1.652,1.0,60.0,7.82,35.7,7.25,27.6,0.0057868,-0.12066600000000002,45.9,1.494279222244614,7.838339347870588,3.233264150930629e-10,0.5323441281944414,226.99455987714418,7.977470390167081,-0.459,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M205,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,205.0,182.2,1.494,1.494,1.0,54.0,8.26,33.1,7.65,26.8,0.0033039999999999996,-0.10856800000000001,46.7,1.4104262728958392,8.275930975569553,5.172990816300023e-10,0.2826672194828064,146.5592325983914,15.533323258143938,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M205B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,205.0,182.2,1.494,1.494,1.0,54.0,8.26,33.1,7.65,26.8,0.0033039999999999996,-0.10856800000000001,46.7,1.4104262728958392,8.275930975569553,5.172990816300023e-10,0.2826672194828064,146.5592325983914,15.533323258143938,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P205,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,205.0,182.3,1.494,1.494,1.0,54.0,8.35,32.9,7.6,27.0,0.0032565000000000003,-0.10659600000000001,47.0,1.413746280752724,8.373853195154297,6.220563859678088e-10,0.2231620852718144,78.11966208006338,18.709694429904296,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M205,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,205.0,184.5,1.652,1.652,1.0,60.0,7.65,36.3,6.9,29.7,0.0028304999999999997,-0.123057,45.4,1.5287776290594624,7.679615339928292,3.5097800202351135e-10,0.29336147102987686,75.77881419172786,9.142346301335367,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M205B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,205.0,183.5,1.652,1.652,1.0,60.0,7.91,35.4,7.3,28.1,0.0017402,-0.120006,46.1,1.4356728166926411,7.934204729441206,1.502012704123315e-10,0.42311674928886606,138.27271599478678,1.7602662588690912,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P205,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,205.0,184.6,1.652,1.652,1.0,60.0,7.67,36.1,6.93,29.6,0.0042185,-0.11732500000000001,45.3,1.54338102449572,7.69666104276134,5.027801421118577e-10,0.2735572729614658,78.69851216746308,16.969041511731167,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P205B,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,205.0,183.4,1.652,1.652,1.0,60.0,7.94,35.9,7.38,27.8,0.005875600000000001,-0.121342,45.9,1.5021587028650996,7.955453254598303,3.266496856806219e-10,0.5194917670108807,266.91888086358483,7.926652475965765,-0.459,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M210,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,210.0,186.7,1.494,1.494,1.0,54.0,8.32,33.2,7.81,26.9,0.0033280000000000007,-0.108896,46.7,1.4050038823317195,8.326060460775956,4.5040386072958607e-10,0.27969799318409483,383.9787309576923,14.130108956605168,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-M210B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,210.0,186.7,1.494,1.494,1.0,54.0,8.32,33.2,7.81,26.9,0.0033280000000000007,-0.108896,46.7,1.4050038823317195,8.326060460775956,4.5040386072958607e-10,0.27969799318409483,383.9787309576923,14.130108956605168,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF190-27-P210,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,210.0,186.8,1.494,1.494,1.0,54.0,8.48,33.0,7.75,27.1,0.0033072,-0.10692000000000002,47.0,1.4152396873920912,8.501643944822634,6.062247236246268e-10,0.21839484851005958,85.56612348852553,18.299159838355717,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M210,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,210.0,189.1,1.652,1.652,1.0,60.0,7.8,36.4,7.05,29.8,0.0028859999999999997,-0.123396,45.4,1.5316689811612296,7.8287210899866695,3.514740018413472e-10,0.2858654773544817,77.63461672703137,8.977018861437479,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M210B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,210.0,188.1,1.652,1.652,1.0,60.0,8.02,35.6,7.43,28.3,0.0017643999999999997,-0.12068400000000003,46.1,1.4420842489856411,8.040576465499443,1.4858217108332993e-10,0.41296417268129687,160.95927062016307,1.5460074515335214,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P210,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,210.0,189.2,1.652,1.652,1.0,60.0,7.82,36.2,7.08,29.7,0.004301,-0.11765000000000002,45.3,1.5463708113662369,7.845817580766692,5.039557254995113e-10,0.2664749204121229,80.71375908165916,16.800758116032863,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P210B,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,210.0,188.0,1.652,1.652,1.0,60.0,8.06,36.1,7.48,28.1,0.0059644,-0.12201800000000003,45.9,1.5163802663451509,8.0774139057132,3.626953053884627e-10,0.49162366109301425,227.54733012422278,8.720935646230094,-0.459,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M215,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,215.0,193.7,1.652,1.652,1.0,60.0,7.95,36.5,7.2,29.9,0.0029415,-0.12373500000000001,45.4,1.5346319028890543,7.977841572330419,3.5222223716001614e-10,0.278644671256885,79.56537801818105,8.821705829585603,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M215B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,215.0,192.6,1.652,1.652,1.0,60.0,8.14,35.8,7.55,28.5,0.0017908000000000002,-0.121362,46.1,1.450492407360395,8.15954434965518,1.5177943204381702e-10,0.4027069976026444,167.72290902293958,1.5947422235561677,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P215,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,215.0,193.8,1.652,1.652,1.0,60.0,7.97,36.4,7.24,29.7,0.004383499999999999,-0.1183,45.3,1.5468073320379507,7.996861483133926,4.5644486198193676e-10,0.29047202345981543,86.18519505082924,15.675278256041437,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P215B,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,215.0,192.6,1.652,1.652,1.0,60.0,8.17,36.3,7.6,28.3,0.0060458,-0.12269400000000001,45.9,1.5243455032996331,8.184810263488727,3.6610757646097926e-10,0.4804562209578289,265.0410983892111,8.677333108037562,-0.459,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M220,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,220.0,198.3,1.652,1.652,1.0,60.0,8.1,36.6,7.34,30.0,0.002997,-0.12407400000000003,45.4,1.5388848323568716,8.127755484930647,3.593584883471925e-10,0.2714242603492909,79.21088767300964,8.831955051982588,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M220B,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,220.0,197.2,1.652,1.652,1.0,60.0,8.24,36.1,7.64,28.8,0.0018127999999999998,-0.12237900000000003,46.1,1.4647002328636844,8.259817331925834,1.589422890199889e-10,0.39170849730965396,162.87148232208025,1.8734755481500707,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P220,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,220.0,198.4,1.652,1.652,1.0,60.0,8.12,36.5,7.4,29.8,0.0044659999999999995,-0.118625,45.3,1.5487808552115103,8.145136320170995,4.5094482033059557e-10,0.2834749298070893,91.57333116444009,15.376360719475061,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-P220B,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,220.0,197.2,1.652,1.652,1.0,60.0,8.28,36.5,7.72,28.5,0.006127199999999999,-0.12337000000000001,45.9,1.5323425460621665,8.29229323263339,3.696641746152573e-10,0.4696235938111189,316.3110009685244,8.638134855073504,-0.459,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd SF220-30-M225,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,225.0,202.9,1.652,1.652,1.0,60.0,8.16,36.8,7.48,30.1,0.0030192,-0.124752,45.4,1.5351321520338108,8.18195229908573,3.0410969282686137e-10,0.28306844512318424,105.22080695341931,7.272448394054055,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-230Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,230.0,204.4,1.652,1.652,1.0,60.0,8.46,36.8,7.94,29.0,0.0041454000000000005,-0.117392,47.7,1.5118738916081083,8.466773656517127,2.255244686257997e-10,0.4320401411839292,539.599376866111,10.743972413482133,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-230QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,230.0,204.4,1.652,1.652,1.0,60.0,8.46,36.8,7.94,29.0,0.0041454000000000005,-0.117392,47.7,1.5118738916081083,8.466773656517127,2.255244686257997e-10,0.4320401411839292,539.599376866111,10.743972413482133,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-230QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,230.0,204.4,1.652,1.652,1.0,60.0,8.46,36.8,7.94,29.0,0.0041454000000000005,-0.117392,47.7,1.5118738916081083,8.466773656517127,2.255244686257997e-10,0.4320401411839292,539.599376866111,10.743972413482133,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-230Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,230.0,204.6,1.6163679999999998,1.636,0.988,60.0,8.46,36.8,7.94,29.0,0.0041454000000000005,-0.117392,47.7,1.5118738916081083,8.466773656517127,2.255244686257997e-10,0.4320401411839292,539.599376866111,10.743972413482133,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-230QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,230.0,204.6,1.6163679999999998,1.636,0.988,60.0,8.46,36.8,7.94,29.0,0.0041454000000000005,-0.117392,47.7,1.5118738916081083,8.466773656517127,2.255244686257997e-10,0.4320401411839292,539.599376866111,10.743972413482133,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-230QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,230.0,204.6,1.6163679999999998,1.636,0.988,60.0,8.46,36.8,7.94,29.0,0.0041454000000000005,-0.117392,47.7,1.5118738916081083,8.466773656517127,2.255244686257997e-10,0.4320401411839292,539.599376866111,10.743972413482133,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-235T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,208.7,1.652,1.652,1.0,60.0,8.65,36.8,8.05,29.1,0.004325000000000001,-0.1288,46.9,1.5626082061069813,8.664409987365717,5.036804635342309e-10,0.39808212814223143,238.9600491583812,7.453018353079268,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-235TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,211.2,1.652,1.652,1.0,60.0,8.65,36.8,8.05,29.1,0.006055000000000001,-0.12512,46.1,1.5408006422465776,8.665359837517556,3.606123527308983e-10,0.4035376947815227,227.25512306278068,7.4556135690033125,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-235TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,208.7,1.652,1.652,1.0,60.0,8.65,36.8,8.05,29.1,0.004325000000000001,-0.1288,46.9,1.5626082061069813,8.664409987365717,5.036804635342309e-10,0.39808212814223143,238.9600491583812,7.453018353079268,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-235Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-235QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-235QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-235Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-235QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-235QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-235Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-235QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-235QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.0,1.652,1.652,1.0,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-235T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,211.2,1.652,1.652,1.0,60.0,8.65,36.8,8.05,29.1,0.006055000000000001,-0.12512,46.1,1.5408006422465776,8.665359837517556,3.606123527308983e-10,0.4035376947815227,227.25512306278068,7.4556135690033125,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-235TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,211.2,1.652,1.652,1.0,60.0,8.65,36.8,8.05,29.1,0.006055000000000001,-0.12512,46.1,1.5408006422465776,8.665359837517556,3.606123527308983e-10,0.4035376947815227,227.25512306278068,7.4556135690033125,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-235TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,211.2,1.652,1.652,1.0,60.0,8.65,36.8,8.05,29.1,0.006055000000000001,-0.12512,46.1,1.5408006422465776,8.665359837517556,3.606123527308983e-10,0.4035376947815227,227.25512306278068,7.4556135690033125,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-235Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-235QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-235QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-235Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-235QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-235QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,235.0,209.1,1.6163679999999998,1.636,0.988,60.0,8.55,37.0,8.05,29.2,0.0041895000000000005,-0.11803,47.7,1.518926553882766,8.553416409869294,2.245171891788114e-10,0.42332579444290497,1059.42725581733,10.59835431690441,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-240T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-240TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-240T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-240TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-240TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-240T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.5,1.6163679999999998,1.636,0.988,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-240TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.5,1.6163679999999998,1.636,0.988,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-240TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.5,1.6163679999999998,1.636,0.988,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-240T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.5,1.6163679999999998,1.636,0.988,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-240TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.5,1.6163679999999998,1.636,0.988,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-240TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,240.0,213.5,1.6163679999999998,1.636,0.988,60.0,8.52,37.3,7.99,30.0,0.0041748,-0.118987,47.9,1.5509117537429797,8.527816303147944,3.025641872956286e-10,0.3452082820257599,376.28724895291816,13.346407654598154,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.75,37.1,8.13,29.5,0.004375,-0.12985,46.9,1.5818923001259233,8.765804741747361,5.601712394336322e-10,0.37291634708209465,206.45821889145606,8.287437867918616,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,215.9,1.652,1.652,1.0,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-240TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.3,1.652,1.652,1.0,60.0,8.75,37.1,8.13,29.5,0.004375,-0.12985,46.9,1.5818923001259233,8.765804741747361,5.601712394336322e-10,0.37291634708209465,206.45821889145606,8.287437867918616,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-240QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-240Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-240QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-240QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.6,1.652,1.652,1.0,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,215.9,1.652,1.652,1.0,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,215.9,1.652,1.652,1.0,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-240TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,215.9,1.652,1.652,1.0,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-240T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.4,1.6163679999999998,1.636,0.988,60.0,8.75,37.1,8.13,29.5,0.004375,-0.12985,46.9,1.5818923001259233,8.765804741747361,5.601712394336322e-10,0.37291634708209465,206.45821889145606,8.287437867918616,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-240TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,216.0,1.6163679999999998,1.636,0.988,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-240TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.4,1.6163679999999998,1.636,0.988,60.0,8.75,37.1,8.13,29.5,0.004375,-0.12985,46.9,1.5818923001259233,8.765804741747361,5.601712394336322e-10,0.37291634708209465,206.45821889145606,8.287437867918616,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-240Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.7,1.6163679999999998,1.636,0.988,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-240QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.7,1.6163679999999998,1.636,0.988,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-240QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.7,1.6163679999999998,1.636,0.988,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-240QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.7,1.6163679999999998,1.636,0.988,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.7,1.6163679999999998,1.636,0.988,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,213.7,1.6163679999999998,1.636,0.988,60.0,8.64,37.3,8.17,29.4,0.0042336000000000006,-0.118987,47.7,1.527831165228816,8.651741475397401,2.1595825001685275e-10,0.4268495008758955,999999.9777919434,10.136531574828584,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,216.0,1.6163679999999998,1.636,0.988,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,216.0,1.6163679999999998,1.636,0.988,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,240.0,216.0,1.6163679999999998,1.636,0.988,60.0,8.75,37.1,8.13,29.5,0.006125000000000001,-0.12614,46.1,1.5597625851516865,8.766742702208111,4.012902442720229e-10,0.3784247672502362,197.77078132417304,8.296571219126822,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-245TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-245T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-245TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-245TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-245T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,218.1,1.6163679999999998,1.636,0.988,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-245TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,218.1,1.6163679999999998,1.636,0.988,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-245TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,218.1,1.6163679999999998,1.636,0.988,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-245T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,218.1,1.6163679999999998,1.636,0.988,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-245TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,218.1,1.6163679999999998,1.636,0.988,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-245TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,245.0,218.1,1.6163679999999998,1.636,0.988,60.0,8.63,37.5,8.11,30.2,0.004228700000000001,-0.11962500000000001,47.9,1.5586951839933925,8.636106889331426,3.0466984894748437e-10,0.3370009887318956,476.2358000911891,13.284965442871359,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-245T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.8,37.2,8.25,29.7,0.0044,-0.1302,46.9,1.582389315746927,8.80697538101569,5.382489034526841e-10,0.35445174142312097,447.16938110713886,7.859281070705116,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-245TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.5,1.652,1.652,1.0,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-245TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,217.9,1.652,1.652,1.0,60.0,8.8,37.2,8.25,29.7,0.0044,-0.1302,46.9,1.582389315746927,8.80697538101569,5.382489034526841e-10,0.35445174142312097,447.16938110713886,7.859281070705116,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-245Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-245QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-245QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-245Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-245QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-245QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-245Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-245QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-245QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.2,1.652,1.652,1.0,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-245T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.5,1.652,1.652,1.0,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-245TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.5,1.652,1.652,1.0,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-245TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.5,1.652,1.652,1.0,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-245T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.0,1.6163679999999998,1.636,0.988,60.0,8.8,37.2,8.25,29.7,0.0044,-0.1302,46.9,1.582389315746927,8.80697538101569,5.382489034526841e-10,0.35445174142312097,447.16938110713886,7.859281070705116,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-245TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.6,1.6163679999999998,1.636,0.988,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-245TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.0,1.6163679999999998,1.636,0.988,60.0,8.8,37.2,8.25,29.7,0.0044,-0.1302,46.9,1.582389315746927,8.80697538101569,5.382489034526841e-10,0.35445174142312097,447.16938110713886,7.859281070705116,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-245Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-245QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-245QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-245Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-245QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-245QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,222.9,1.60066,1.63,0.982,60.0,8.8,37.5,8.25,29.7,0.00528,-0.11249999999999999,46.6,1.4674187883459988,8.81170116577117,6.93044921427263e-11,0.4215352492655508,317.02058749357764,6.661989474307983,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,218.3,1.6163679999999998,1.636,0.988,60.0,8.73,37.5,8.28,29.6,0.004277700000000001,-0.11962500000000001,47.7,1.5402031439739807,8.730003515965745,2.3283847051581515e-10,0.4025099529192231,999999.6486503951,10.725338662585989,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.6,1.6163679999999998,1.636,0.988,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.6,1.6163679999999998,1.636,0.988,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,220.6,1.6163679999999998,1.636,0.988,60.0,8.8,37.2,8.25,29.7,0.006160000000000001,-0.12648000000000004,46.1,1.560325379335217,8.80775655583494,3.857055282807752e-10,0.35987141044006415,408.2829443083664,7.872008095851621,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,245.0,222.9,1.60066,1.63,0.982,60.0,8.8,37.5,8.25,29.7,0.00528,-0.11249999999999999,46.6,1.4674187883459988,8.81170116577117,6.93044921427263e-11,0.4215352492655508,317.02058749357764,6.661989474307983,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-250T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.5,1.652,1.652,1.0,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-250TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.5,1.652,1.652,1.0,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-250T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.5,1.652,1.652,1.0,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-250TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.5,1.652,1.652,1.0,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-250TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.5,1.652,1.652,1.0,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-250T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.7,1.6163679999999998,1.636,0.988,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-250TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.7,1.6163679999999998,1.636,0.988,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-250TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.7,1.6163679999999998,1.636,0.988,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-250T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.7,1.6163679999999998,1.636,0.988,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-250TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.7,1.6163679999999998,1.636,0.988,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-250TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,250.0,222.7,1.6163679999999998,1.636,0.988,60.0,8.73,37.6,8.22,30.4,0.004277700000000001,-0.11994400000000001,47.9,1.5647580240042387,8.734558456421627,3.1795731980024137e-10,0.3169594057048674,607.0161249754552,13.564034881557658,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-250T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.4,1.652,1.652,1.0,60.0,8.89,37.4,8.33,30.0,0.004445,-0.1309,46.9,1.5957323232436147,8.897528211671126,5.831966070272663e-10,0.3327353349016125,392.9244407715577,8.475285640809732,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-250TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.1,1.652,1.652,1.0,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-250TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.4,1.652,1.652,1.0,60.0,8.89,37.4,8.33,30.0,0.004445,-0.1309,46.9,1.5957323232436147,8.897528211671126,5.831966070272663e-10,0.3327353349016125,392.9244407715577,8.475285640809732,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-250Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-250QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-250QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-250Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-250QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-250QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-250Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-250QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-250QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.7,1.652,1.652,1.0,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-250T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.1,1.652,1.652,1.0,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-250TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.1,1.652,1.652,1.0,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-250TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.1,1.652,1.652,1.0,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-250T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.6,1.6163679999999998,1.636,0.988,60.0,8.89,37.4,8.33,30.0,0.004445,-0.1309,46.9,1.5957323232436147,8.897528211671126,5.831966070272663e-10,0.3327353349016125,392.9244407715577,8.475285640809732,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-250TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.2,1.6163679999999998,1.636,0.988,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-250TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.6,1.6163679999999998,1.636,0.988,60.0,8.89,37.4,8.33,30.0,0.004445,-0.1309,46.9,1.5957323232436147,8.897528211671126,5.831966070272663e-10,0.3327353349016125,392.9244407715577,8.475285640809732,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-250Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-250QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-250QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-250Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-250QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-250QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,227.5,1.60066,1.63,0.982,60.0,8.74,37.2,8.22,30.4,0.005244,-0.11160000000000002,46.6,1.4785295527850848,8.747551772828974,1.021852815537122e-10,0.2872483460284122,332.44520889726755,10.12057002191497,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,222.9,1.6163679999999998,1.636,0.988,60.0,8.82,37.7,8.39,29.8,0.0043218,-0.12026300000000002,47.7,1.5515217607999892,8.820003379355786,2.469817580004315e-10,0.3829278161074627,999999.6221718861,11.160892733836198,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.2,1.6163679999999998,1.636,0.988,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.2,1.6163679999999998,1.636,0.988,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,225.2,1.6163679999999998,1.636,0.988,60.0,8.89,37.4,8.33,30.0,0.006223000000000001,-0.12716,46.1,1.5734436298869765,8.898286661226306,4.18094342040024e-10,0.33817855760430027,362.8009121073354,8.49301398854088,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-250W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,227.5,1.60066,1.63,0.982,60.0,8.74,37.2,8.22,30.4,0.005244,-0.11160000000000002,46.6,1.4785295527850848,8.747551772828974,1.021852815537122e-10,0.2872483460284122,332.44520889726755,10.12057002191497,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-250,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,226.8,1.67,1.67,1.0,60.0,8.72,37.6,8.2,30.5,0.00481344,-0.1215232,45.5,1.5359842154897723,8.726532922139747,2.018536643209944e-10,0.3111695095298609,415.3422422199551,7.994236348180501,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-250,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,227.6,1.67,1.67,1.0,60.0,8.72,37.6,8.2,30.5,0.004360000000000001,-0.1128,45.8,1.4907947452938524,8.727914786896454,9.595800612385257e-11,0.3227212545043958,355.55343299302734,9.703873632328255,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-250W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,250.0,227.6,1.67,1.67,1.0,60.0,8.72,37.6,8.2,30.5,0.004360000000000001,-0.1128,45.8,1.4907947452938524,8.727914786896454,9.595800612385257e-11,0.3227212545043958,355.55343299302734,9.703873632328255,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-255T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.1,1.652,1.652,1.0,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-255TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.1,1.652,1.652,1.0,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-255T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.1,1.652,1.652,1.0,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-255TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.1,1.652,1.652,1.0,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-255TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.1,1.652,1.652,1.0,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-255T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.2,1.6163679999999998,1.636,0.988,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-255TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.2,1.6163679999999998,1.636,0.988,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-255TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.2,1.6163679999999998,1.636,0.988,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-255T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.2,1.6163679999999998,1.636,0.988,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-255TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.2,1.6163679999999998,1.636,0.988,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-255TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,255.0,227.2,1.6163679999999998,1.636,0.988,60.0,8.81,37.8,8.32,30.6,0.004316900000000001,-0.12058200000000001,47.9,1.5717769466165201,8.812201256559572,3.1560344373470175e-10,0.3104776194030812,1242.6128281709643,13.401196717824446,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-255T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.6,1.652,1.652,1.0,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-255TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.6,1.652,1.652,1.0,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-0-255TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.6,1.652,1.652,1.0,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-255Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-255QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-2-255QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-255Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-255QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-3-255QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-255Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-255QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-255QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.1,1.652,1.652,1.0,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-255T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.6,1.652,1.652,1.0,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-255TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.6,1.652,1.652,1.0,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PA-4-255TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.6,1.652,1.652,1.0,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-255T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.8,1.6163679999999998,1.636,0.988,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-255TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.8,1.6163679999999998,1.636,0.988,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-255TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.8,1.6163679999999998,1.636,0.988,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-255Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-255QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-2-255QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-255Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-255QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-255QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,232.2,1.60066,1.63,0.982,60.0,8.89,38.0,8.29,30.8,0.005334,-0.11399999999999999,46.6,1.5100776134353537,8.905305877885835,1.0255916039216213e-10,0.3236775953285123,187.9992741598833,10.031095840482568,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,229.2,1.6163679999999998,1.636,0.988,60.0,8.91,37.9,8.51,30.0,0.0056133,-0.12203800000000001,46.5,1.5745776925109063,8.910003157021343,3.136398891098518e-10,0.35408247896965656,999957.4864298735,12.006184109784524,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.8,1.6163679999999998,1.636,0.988,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.8,1.6163679999999998,1.636,0.988,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,228.8,1.6163679999999998,1.636,0.988,60.0,8.95,37.5,8.48,30.1,0.0054595,-0.134625,46.2,1.5900377749185208,8.97372839957853,5.133576783530306e-10,0.3288535801968639,999999.9787017963,4.42205743981867,-0.467,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-255W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,232.2,1.60066,1.63,0.982,60.0,8.89,38.0,8.29,30.8,0.005334,-0.11399999999999999,46.6,1.5100776134353537,8.905305877885835,1.0255916039216213e-10,0.3236775953285123,187.9992741598833,10.031095840482568,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-255,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,231.4,1.67,1.67,1.0,60.0,8.86,37.8,8.31,30.7,0.0048907199999999994,-0.12216959999999999,45.5,1.5473228509805514,8.868672241592527,2.149408893825933e-10,0.30239238749767594,308.9393828829069,8.413687650403936,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-255,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,232.2,1.67,1.67,1.0,60.0,8.86,37.8,8.31,30.7,0.00443,-0.1134,45.8,1.5017055190199793,8.870134600055577,1.0217441179945594e-10,0.3139165692018985,274.43618285894183,10.129599454224259,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-255W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,255.0,232.2,1.67,1.67,1.0,60.0,8.86,37.8,8.31,30.7,0.00443,-0.1134,45.8,1.5017055190199793,8.870134600055577,1.0217441179945594e-10,0.3139165692018985,274.43618285894183,10.129599454224259,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-260T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.7,1.652,1.652,1.0,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-0-260TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.7,1.652,1.652,1.0,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-260T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.7,1.652,1.652,1.0,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-260TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.7,1.652,1.652,1.0,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HA-4-260TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.7,1.652,1.652,1.0,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-260T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.8,1.6163679999999998,1.636,0.988,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-260TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.8,1.6163679999999998,1.636,0.988,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-0-260TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.8,1.6163679999999998,1.636,0.988,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-260T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.8,1.6163679999999998,1.636,0.988,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-260TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.8,1.6163679999999998,1.636,0.988,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60M6-HB-4-260TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,260.0,231.8,1.6163679999999998,1.636,0.988,60.0,8.92,37.9,8.46,30.7,0.0043708,-0.12090100000000001,47.9,1.574154493816874,8.933556467985445,3.124406276805367e-10,0.3045075797057552,999999.9792538659,13.17197409577963,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-260T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,233.1,1.60066,1.63,0.982,60.0,8.99,37.7,8.56,30.4,0.005394,-0.13572,46.8,1.5957644619279907,8.990002573622668,4.937797577212577e-10,0.2860557940266425,999999.8576070627,3.797226987069603,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-260TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,233.1,1.60066,1.63,0.982,60.0,8.99,37.7,8.56,30.4,0.005394,-0.13572,46.8,1.5957644619279907,8.990002573622668,4.937797577212577e-10,0.2860557940266425,999999.8576070627,3.797226987069603,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,236.9,1.60066,1.63,0.982,60.0,8.93,38.1,8.35,31.2,0.005358,-0.1143,46.6,1.5205326390251983,8.94181998351557,1.1492651552883338e-10,0.2785023137524016,210.40856290686412,11.00080800722346,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,233.1,1.60066,1.63,0.982,60.0,8.99,37.7,8.56,30.4,0.005394,-0.13572,46.8,1.5957644619279907,8.990002573622668,4.937797577212577e-10,0.2860557940266425,999999.8576070627,3.797226987069603,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,233.1,1.60066,1.63,0.982,60.0,8.99,37.7,8.56,30.4,0.005394,-0.13572,46.8,1.5957644619279907,8.990002573622668,4.937797577212577e-10,0.2860557940266425,999999.8576070627,3.797226987069603,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-260W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,236.9,1.60066,1.63,0.982,60.0,8.93,38.1,8.35,31.2,0.005358,-0.1143,46.6,1.5205326390251983,8.94181998351557,1.1492651552883338e-10,0.2785023137524016,210.40856290686412,11.00080800722346,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-260,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,236.1,1.67,1.67,1.0,60.0,8.98,38.1,8.42,30.9,0.00495696,-0.12313919999999999,45.5,1.5586037508696002,8.989118872359365,2.1442321707034433e-10,0.3067939345826184,302.1217689011027,8.275596675967178,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-260,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,236.9,1.67,1.67,1.0,60.0,8.98,38.1,8.42,30.9,0.00449,-0.1143,45.8,1.5126847557677645,8.990631726236488,1.0193207882305645e-10,0.3182310457778739,268.7912521274052,9.989836900878913,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-260W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,260.0,236.9,1.67,1.67,1.0,60.0,8.98,38.1,8.42,30.9,0.00449,-0.1143,45.8,1.5126847557677645,8.990631726236488,1.0193207882305645e-10,0.3182310457778739,268.7912521274052,9.989836900878913,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-265T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,237.8,1.60066,1.63,0.982,60.0,9.02,37.8,8.67,30.6,0.005412,-0.13608,46.8,1.610951788362157,9.020185952888344,5.815594288724685e-10,0.22529027613725525,10928.221414049696,5.153559565147258,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-265TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,237.8,1.60066,1.63,0.982,60.0,9.02,37.8,8.67,30.6,0.005412,-0.13608,46.8,1.610951788362157,9.020185952888344,5.815594288724685e-10,0.22529027613725525,10928.221414049696,5.153559565147258,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-265T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,237.8,1.60066,1.63,0.982,60.0,9.02,37.8,8.67,30.6,0.005412,-0.13608,46.8,1.610951788362157,9.020185952888344,5.815594288724685e-10,0.22529027613725525,10928.221414049696,5.153559565147258,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-265TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,237.8,1.60066,1.63,0.982,60.0,9.02,37.8,8.67,30.6,0.005412,-0.13608,46.8,1.610951788362157,9.020185952888344,5.815594288724685e-10,0.22529027613725525,10928.221414049696,5.153559565147258,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-265,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,240.7,1.67,1.67,1.0,60.0,9.12,38.3,8.53,31.1,0.00503424,-0.1237856,45.5,1.5699071769322093,9.13121839644827,2.2790447318747754e-10,0.2983129434235616,242.51365277007562,8.6835254878015,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-265,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,241.6,1.67,1.67,1.0,60.0,9.12,38.3,8.53,31.1,0.00456,-0.1149,45.8,1.5235682661168868,9.132812425466883,1.0834650194884396e-10,0.3097227156188181,220.46343523405287,10.404721849519516,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-265W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,265.0,241.6,1.67,1.67,1.0,60.0,9.12,38.3,8.53,31.1,0.00456,-0.1149,45.8,1.5235682661168868,9.132812425466883,1.0834650194884396e-10,0.3097227156188181,220.46343523405287,10.404721849519516,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,270.0,242.4,1.60066,1.63,0.982,60.0,9.04,37.8,8.77,30.8,0.005423999999999999,-0.13608,46.8,1.6230358475184525,9.040001342312687,6.943577615360404e-10,0.14838711067190338,999999.9129359458,6.654072460517935,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,270.0,242.4,1.60066,1.63,0.982,60.0,9.04,37.8,8.77,30.8,0.005423999999999999,-0.13608,46.8,1.6230358475184525,9.040001342312687,6.943577615360404e-10,0.14838711067190338,999999.9129359458,6.654072460517935,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-270T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,270.0,242.4,1.60066,1.63,0.982,60.0,9.04,37.8,8.77,30.8,0.005423999999999999,-0.13608,46.8,1.6230358475184525,9.040001342312687,6.943577615360404e-10,0.14838711067190338,999999.9129359458,6.654072460517935,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-270TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,270.0,242.4,1.60066,1.63,0.982,60.0,9.04,37.8,8.77,30.8,0.005423999999999999,-0.13608,46.8,1.6230358475184525,9.040001342312687,6.943577615360404e-10,0.14838711067190338,999999.9129359458,6.654072460517935,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-270,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,270.0,245.4,1.67,1.67,1.0,60.0,9.22,38.5,8.66,31.2,0.00508944,-0.124432,45.5,1.5728539368510488,9.227933396133926,2.134990984181837e-10,0.3053539359520332,354.8749640083916,8.001133512204373,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,250.1,1.67,1.67,1.0,60.0,9.31,38.7,8.79,31.3,0.00513912,-0.1250784,45.5,1.5750491961526547,9.31345684044264,1.9772378395703852e-10,0.31250561790854703,841.6437613373421,7.230519837731701,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-275T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,244.1,1.966,1.966,1.0,72.0,8.38,44.5,7.75,35.6,0.004190000000000001,-0.15575,46.9,1.9091582368186093,8.398605308624123,6.157806832451885e-10,0.43377282076384277,195.37525545602793,9.520335300351027,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-275TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,247.1,1.966,1.966,1.0,72.0,8.38,44.5,7.75,35.6,0.005866000000000001,-0.15130000000000002,46.1,1.8823250613869589,8.39952271059899,4.413431233937629e-10,0.4408210508940011,189.21967308839794,9.535414205996593,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-275TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,244.1,1.966,1.966,1.0,72.0,8.38,44.5,7.75,35.6,0.004190000000000001,-0.15575,46.9,1.9091582368186093,8.398605308624123,6.157806832451885e-10,0.43377282076384277,195.37525545602793,9.520335300351027,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-275T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,247.1,1.966,1.966,1.0,72.0,8.38,44.5,7.75,35.6,0.005866000000000001,-0.15130000000000002,46.1,1.8823250613869589,8.39952271059899,4.413431233937629e-10,0.4408210508940011,189.21967308839794,9.535414205996593,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-275TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,247.1,1.966,1.966,1.0,72.0,8.38,44.5,7.75,35.6,0.005866000000000001,-0.15130000000000002,46.1,1.8823250613869589,8.39952271059899,4.413431233937629e-10,0.4408210508940011,189.21967308839794,9.535414205996593,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-275TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,275.0,247.1,1.966,1.966,1.0,72.0,8.38,44.5,7.75,35.6,0.005866000000000001,-0.15130000000000002,46.1,1.8823250613869589,8.39952271059899,4.413431233937629e-10,0.4408210508940011,189.21967308839794,9.535414205996593,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-280T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,248.7,1.966,1.966,1.0,72.0,8.43,44.6,7.84,35.7,0.004215,-0.1561,46.9,1.9082466871101216,8.443740644511562,5.852003785935867e-10,0.4294396924234408,263.46489626168346,8.998305544436494,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-280TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,251.7,1.966,1.966,1.0,72.0,8.43,44.6,7.84,35.7,0.005901000000000001,-0.15164000000000002,46.1,1.8815055524886837,8.444579675530937,4.1946093187377256e-10,0.4363778340104332,252.3146440820533,9.014172839750517,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-280TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,248.7,1.966,1.966,1.0,72.0,8.43,44.6,7.84,35.7,0.004215,-0.1561,46.9,1.9082466871101216,8.443740644511562,5.852003785935867e-10,0.4294396924234408,263.46489626168346,8.998305544436494,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-280Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-280QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-280QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-280Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-280QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-280QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-280Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-280QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-280QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.0,1.966,1.966,1.0,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-280T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,251.7,1.966,1.966,1.0,72.0,8.43,44.6,7.84,35.7,0.005901000000000001,-0.15164000000000002,46.1,1.8815055524886837,8.444579675530937,4.1946093187377256e-10,0.4363778340104332,252.3146440820533,9.014172839750517,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-280TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,251.7,1.966,1.966,1.0,72.0,8.43,44.6,7.84,35.7,0.005901000000000001,-0.15164000000000002,46.1,1.8815055524886837,8.444579675530937,4.1946093187377256e-10,0.4363778340104332,252.3146440820533,9.014172839750517,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-280TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,251.7,1.966,1.966,1.0,72.0,8.43,44.6,7.84,35.7,0.005901000000000001,-0.15164000000000002,46.1,1.8815055524886837,8.444579675530937,4.1946093187377256e-10,0.4363778340104332,252.3146440820533,9.014172839750517,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-280Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-280QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-280QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-280Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-280QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-280QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-280Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-280QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-280QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,280.0,249.2,1.932528,1.956,0.988,72.0,8.47,44.7,7.98,35.1,0.004150300000000001,-0.14259300000000003,47.7,1.829225978109072,8.4721751929546,2.061784297537358e-10,0.5424060873147155,2112.081355636593,9.920174356320171,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-285T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.3,1.966,1.966,1.0,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-285TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.3,1.966,1.966,1.0,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-285TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.3,1.966,1.966,1.0,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-285T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.3,1.966,1.966,1.0,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-285TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.3,1.966,1.966,1.0,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-285TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.3,1.966,1.966,1.0,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-285T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.5,1.932528,1.956,0.988,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-285TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.5,1.932528,1.956,0.988,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-285TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.5,1.932528,1.956,0.988,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-285T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.5,1.932528,1.956,0.988,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-285TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.5,1.932528,1.956,0.988,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-285TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,285.0,253.5,1.932528,1.956,0.988,72.0,8.41,44.6,7.91,36.0,0.0041209,-0.142274,47.9,1.8553895393756994,8.415254783613687,3.032798378799626e-10,0.399081210029512,638.7083107044197,13.476892383719502,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-285T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.2,1.966,1.966,1.0,72.0,8.53,44.8,7.95,35.9,0.0042650000000000006,-0.15679999999999997,46.9,1.9158470872369338,8.541924265290769,5.866940929653976e-10,0.4204467443350119,300.76584402680703,8.909786141429407,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-285TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.3,1.966,1.966,1.0,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-285TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.2,1.966,1.966,1.0,72.0,8.53,44.8,7.95,35.9,0.0042650000000000006,-0.15679999999999997,46.9,1.9158470872369338,8.541924265290769,5.866940929653976e-10,0.4204467443350119,300.76584402680703,8.909786141429407,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-285Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-285QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-285QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-285QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-285Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-285QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-285QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.6,1.966,1.966,1.0,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-285T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.3,1.966,1.966,1.0,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-285TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.3,1.966,1.966,1.0,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-285TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.3,1.966,1.966,1.0,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-285T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.4,1.932528,1.956,0.988,72.0,8.53,44.8,7.95,35.9,0.0042650000000000006,-0.15679999999999997,46.9,1.9158470872369338,8.541924265290769,5.866940929653976e-10,0.4204467443350119,300.76584402680703,8.909786141429407,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-285TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.4,1.932528,1.956,0.988,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-285TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.4,1.932528,1.956,0.988,72.0,8.53,44.8,7.95,35.9,0.0042650000000000006,-0.15679999999999997,46.9,1.9158470872369338,8.541924265290769,5.866940929653976e-10,0.4204467443350119,300.76584402680703,8.909786141429407,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-285Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-285QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-285QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-285Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-285QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-285QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-285Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-285QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-285QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,253.7,1.932528,1.956,0.988,72.0,8.56,44.8,8.1,35.2,0.004194400000000001,-0.14291199999999998,47.7,1.832012238345139,8.580577280736494,2.0572328252088182e-10,0.5332725780844298,999999.9358290348,9.780144110407521,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-285T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.4,1.932528,1.956,0.988,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-285TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.4,1.932528,1.956,0.988,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-285TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,285.0,256.4,1.932528,1.956,0.988,72.0,8.53,44.8,7.95,35.9,0.005971000000000001,-0.15231999999999998,46.1,1.8890202679002468,8.542734373281899,4.205709702725053e-10,0.4273137582515744,286.2321517842482,8.926721540264598,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-290T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,257.9,1.966,1.966,1.0,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-290TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,257.9,1.966,1.966,1.0,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-290TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,257.9,1.966,1.966,1.0,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-290T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,257.9,1.966,1.966,1.0,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-290TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,257.9,1.966,1.966,1.0,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-290TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,257.9,1.966,1.966,1.0,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-290T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-290TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-290TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-290T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-290TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-290TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.48,44.9,8.01,36.2,0.0041552,-0.143231,47.9,1.8625339189933532,8.48174167858526,2.869489469656995e-10,0.4048660371705603,1971.240292361041,12.878605947797976,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-290T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,257.8,1.966,1.966,1.0,72.0,8.57,45.1,8.01,36.2,0.004285,-0.15785,46.9,1.9276001671580671,8.579413631498914,5.836635321585015e-10,0.4125973491849914,375.62131142704817,8.813599401634434,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-290TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,260.9,1.966,1.966,1.0,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-290TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,257.8,1.966,1.966,1.0,72.0,8.57,45.1,8.01,36.2,0.004285,-0.15785,46.9,1.9276001671580671,8.579413631498914,5.836635321585015e-10,0.4125973491849914,375.62131142704817,8.813599401634434,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-290QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.2,1.966,1.966,1.0,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-290Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.2,1.966,1.966,1.0,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-290QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.2,1.966,1.966,1.0,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-290Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.2,1.966,1.966,1.0,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-290QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.2,1.966,1.966,1.0,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-290QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.2,1.966,1.966,1.0,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-290T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,260.9,1.966,1.966,1.0,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-290TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,260.9,1.966,1.966,1.0,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-290TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,260.9,1.966,1.966,1.0,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-290T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.57,45.1,8.01,36.2,0.004285,-0.15785,46.9,1.9276001671580671,8.579413631498914,5.836635321585015e-10,0.4125973491849914,375.62131142704817,8.813599401634434,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-290TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,261.0,1.932528,1.956,0.988,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-290TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.0,1.932528,1.956,0.988,72.0,8.57,45.1,8.01,36.2,0.004285,-0.15785,46.9,1.9276001671580671,8.579413631498914,5.836635321585015e-10,0.4125973491849914,375.62131142704817,8.813599401634434,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-290Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-290QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-290QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-290Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-290QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-290QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-290Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-290QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-290QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-290T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,261.0,1.932528,1.956,0.988,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-290TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,261.0,1.932528,1.956,0.988,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-290TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,261.0,1.932528,1.956,0.988,72.0,8.57,45.1,8.01,36.2,0.005999000000000001,-0.15334,46.1,1.900634452874822,8.580174791685149,4.184541098750419e-10,0.4194530415676278,353.29601917173835,8.832070464643081,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-290,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,263.9,1.956224,1.972,0.992,72.0,8.49,44.4,8.02,36.2,0.0042450000000000005,-0.13319999999999999,45.8,1.7612843598144268,8.494110799472697,9.506442749984376e-11,0.3647632961870234,753.3426889604668,9.841447667411055,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-290W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,290.0,263.9,1.956224,1.972,0.992,72.0,8.49,44.4,8.02,36.2,0.0042450000000000005,-0.13319999999999999,45.8,1.7612843598144268,8.494110799472697,9.506442749984376e-11,0.3647632961870234,753.3426889604668,9.841447667411055,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-295T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.5,1.966,1.966,1.0,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-295TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.5,1.966,1.966,1.0,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-295TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.5,1.966,1.966,1.0,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-295T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.5,1.966,1.966,1.0,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-295TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.5,1.966,1.966,1.0,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-295TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.5,1.966,1.966,1.0,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-295T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.6,1.932528,1.956,0.988,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-295TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.6,1.932528,1.956,0.988,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-295TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.6,1.932528,1.956,0.988,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-295T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.6,1.932528,1.956,0.988,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-295TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.6,1.932528,1.956,0.988,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-295TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,295.0,262.6,1.932528,1.956,0.988,72.0,8.53,45.0,8.08,36.5,0.004179700000000001,-0.14355,47.9,1.8705650733389045,8.530003171427294,3.0420564030691207e-10,0.3714799452532749,999573.4061652082,13.349363767151125,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-295T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.4,1.966,1.966,1.0,72.0,8.65,45.3,8.12,36.4,0.004325000000000001,-0.15854999999999997,46.9,1.9328743601410736,8.655727276144585,5.690980209146683e-10,0.4050709764631678,611.7857150833655,8.494783622195007,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-295TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.5,1.966,1.966,1.0,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-295TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.4,1.966,1.966,1.0,72.0,8.65,45.3,8.12,36.4,0.004325000000000001,-0.15854999999999997,46.9,1.9328743601410736,8.655727276144585,5.690980209146683e-10,0.4050709764631678,611.7857150833655,8.494783622195007,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-295QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-295QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-295QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.8,1.966,1.966,1.0,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-295T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.5,1.966,1.966,1.0,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-295TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.5,1.966,1.966,1.0,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-295TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.5,1.966,1.966,1.0,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-295T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.5,1.932528,1.956,0.988,72.0,8.65,45.3,8.12,36.4,0.004325000000000001,-0.15854999999999997,46.9,1.9328743601410736,8.655727276144585,5.690980209146683e-10,0.4050709764631678,611.7857150833655,8.494783622195007,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-295TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.7,1.932528,1.956,0.988,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-295TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.5,1.932528,1.956,0.988,72.0,8.65,45.3,8.12,36.4,0.004325000000000001,-0.15854999999999997,46.9,1.9328743601410736,8.655727276144585,5.690980209146683e-10,0.4050709764631678,611.7857150833655,8.494783622195007,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-295QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-295QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,268.4,1.9148999999999998,1.95,0.982,72.0,8.55,44.9,8.11,36.4,0.00513,-0.1347,46.6,1.7693005654416516,8.55074245249945,8.133940015611673e-11,0.3970869568433896,4572.811924702442,8.266944212187763,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.7,1.932528,1.956,0.988,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.7,1.932528,1.956,0.988,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.7,1.932528,1.956,0.988,72.0,8.65,45.3,8.12,36.4,0.006055000000000001,-0.15402,46.1,1.9058864855162656,8.6564261063237,4.080425357580677e-10,0.41183894867315646,554.3649483781941,8.514109038153508,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-295W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,268.4,1.9148999999999998,1.95,0.982,72.0,8.55,44.9,8.11,36.4,0.00513,-0.1347,46.6,1.7693005654416516,8.55074245249945,8.133940015611673e-11,0.3970869568433896,4572.811924702442,8.266944212187763,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,268.6,1.956224,1.972,0.992,72.0,8.6,44.6,8.11,36.4,0.0043,-0.1338,45.8,1.7717201543540217,8.605444515700654,9.957278449891629e-11,0.3562993854581624,562.8002825927539,10.145322137996965,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.1,1.956224,1.972,0.992,72.0,8.42,45.1,8.11,36.4,0.00421842,-0.143869,47.7,1.8245535299589024,8.42023038332789,1.5490859677553663e-10,0.3278111844182966,11980.800473147681,7.449966831981877,-0.4257,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,265.1,1.956224,1.972,0.992,72.0,8.42,45.1,8.11,36.4,0.00421842,-0.143869,47.7,1.8245535299589024,8.42023038332789,1.5490859677553663e-10,0.3278111844182966,11980.800473147681,7.449966831981877,-0.4257,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-295W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,295.0,268.6,1.956224,1.972,0.992,72.0,8.6,44.6,8.11,36.4,0.0043,-0.1338,45.8,1.7717201543540217,8.605444515700654,9.957278449891629e-11,0.3562993854581624,562.8002825927539,10.145322137996965,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-300T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.1,1.966,1.966,1.0,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-300TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.1,1.966,1.966,1.0,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-300TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.1,1.966,1.966,1.0,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-300T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.1,1.966,1.966,1.0,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-300TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.1,1.966,1.966,1.0,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-300TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.1,1.966,1.966,1.0,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-300T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.2,1.932528,1.956,0.988,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-300TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.2,1.932528,1.956,0.988,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-300TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.2,1.932528,1.956,0.988,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-300T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.2,1.932528,1.956,0.988,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-300TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.2,1.932528,1.956,0.988,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-300TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,267.2,1.932528,1.956,0.988,72.0,8.61,45.2,8.17,36.7,0.0042189,-0.144188,47.9,1.8796091243041957,8.62532684937144,3.1049436482445665e-10,0.36365773350838493,999999.9842877123,13.435861254728401,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-300T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,268.1,1.966,1.966,1.0,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-300TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,268.1,1.966,1.966,1.0,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-300QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-300QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-300QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.4,1.966,1.966,1.0,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-300T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,268.1,1.966,1.966,1.0,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-300TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,268.1,1.966,1.966,1.0,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-300T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,268.2,1.932528,1.956,0.988,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-300TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,268.2,1.932528,1.956,0.988,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-300QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-300QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,273.0,1.9148999999999998,1.95,0.982,72.0,8.6,45.0,8.22,36.5,0.00516,-0.135,46.6,1.778296097759475,8.600003089635514,8.802811750434894e-11,0.3592113457923127,999998.1187676004,8.905149718602637,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,268.2,1.932528,1.956,0.988,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,300.0,268.2,1.932528,1.956,0.988,72.0,8.72,45.5,8.22,36.5,0.0052320000000000005,-0.1638,47.1,1.9171449184618503,8.72248564720359,4.2843759033471723e-10,0.4170413554307432,1463.0411540096666,2.8749846496389573,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-300W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,273.0,1.9148999999999998,1.95,0.982,72.0,8.6,45.0,8.22,36.5,0.00516,-0.135,46.6,1.778296097759475,8.600003089635514,8.802811750434894e-11,0.3592113457923127,999998.1187676004,8.905149718602637,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-300,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,271.2,1.956224,1.972,0.992,72.0,8.7,44.8,8.2,36.6,0.0050373,-0.18712959999999998,46.3,1.8637666085254359,8.704068232552007,3.1421813268257596e-10,0.3273430646096937,700.0301530333481,-13.565492834691172,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-300,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,273.2,1.956224,1.972,0.992,72.0,8.7,44.8,8.2,36.6,0.00435,-0.1344,45.8,1.7811105906980116,8.705877425602033,1.0273456207936616e-10,0.34851331544858677,515.883362462261,10.322816202717615,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-300Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,269.7,1.956224,1.972,0.992,72.0,8.57,45.3,8.2,36.6,0.00429357,-0.144507,47.7,1.8272897992445896,8.57000309167912,1.4671189481935644e-10,0.36067489697609606,999985.2554071452,6.826973953257631,-0.4257,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-300QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,269.7,1.956224,1.972,0.992,72.0,8.57,45.3,8.2,36.6,0.00429357,-0.144507,47.7,1.8272897992445896,8.57000309167912,1.4671189481935644e-10,0.36067489697609606,999985.2554071452,6.826973953257631,-0.4257,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-300W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,300.0,273.2,1.956224,1.972,0.992,72.0,8.7,44.8,8.2,36.6,0.00435,-0.1344,45.8,1.7811105906980116,8.705877425602033,1.0273456207936616e-10,0.34851331544858677,515.883362462261,10.322816202717615,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-305T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.7,1.966,1.966,1.0,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-305TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.7,1.966,1.966,1.0,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-305TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.7,1.966,1.966,1.0,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-305T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.7,1.966,1.966,1.0,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-305TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.7,1.966,1.966,1.0,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-305TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.7,1.966,1.966,1.0,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-305T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.8,1.932528,1.956,0.988,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-305TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.8,1.932528,1.956,0.988,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-305TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.8,1.932528,1.956,0.988,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-305T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.8,1.932528,1.956,0.988,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-305TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.8,1.932528,1.956,0.988,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-305TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,305.0,271.8,1.932528,1.956,0.988,72.0,8.68,45.5,8.26,36.9,0.0042532,-0.145145,47.9,1.8952683673417623,8.680003006668532,3.25344141867029e-10,0.3462447085481172,999999.9536676933,13.805077368447327,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-305T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.5,1.966,1.966,1.0,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-305TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.5,1.966,1.966,1.0,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-0-305TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.5,1.966,1.966,1.0,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-305QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-2-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-305QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-3-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-305QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.0,1.966,1.966,1.0,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-305T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.5,1.966,1.966,1.0,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-305TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.5,1.966,1.966,1.0,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PA-4-305TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.5,1.966,1.966,1.0,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.7,1.932528,1.956,0.988,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.7,1.932528,1.956,0.988,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-305TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.7,1.932528,1.956,0.988,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-305QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-2-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-3-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,277.7,1.9148999999999998,1.95,0.982,72.0,8.65,45.2,8.33,36.6,0.00519,-0.1356,46.6,1.7915589067620068,8.650232272594826,9.546370815875267e-11,0.32134690772036084,11967.210103286729,9.570502707967446,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305QB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.2,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.005607000000000001,-0.14651,46.5,1.887127066724927,8.900003970421787,3.007693378644883e-10,0.4458717446087623,999999.9455451646,11.637544492588773,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.7,1.932528,1.956,0.988,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305TB,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.7,1.932528,1.956,0.988,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,273.7,1.932528,1.956,0.988,72.0,8.8,45.7,8.32,36.7,0.005368,-0.164063,46.2,1.9389188352502198,8.800003669976043,5.107761276675639e-10,0.4058557277101665,973894.9629939733,4.542876764784867,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-305W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,277.7,1.9148999999999998,1.95,0.982,72.0,8.65,45.2,8.33,36.6,0.00519,-0.1356,46.6,1.7915589067620068,8.650232272594826,9.546370815875267e-11,0.32134690772036084,11967.210103286729,9.570502707967446,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-305,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,275.9,1.956224,1.972,0.992,72.0,8.81,45.0,8.29,36.8,0.0051009900000000006,-0.18796500000000002,46.3,1.87492089385096,8.815251932886552,3.2928201895267026e-10,0.3192674997135578,535.5642098569223,-13.321230627118606,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-305,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,277.9,1.956224,1.972,0.992,72.0,8.81,45.0,8.29,36.8,0.004405000000000001,-0.135,45.8,1.791529404249954,8.817137848966421,1.0747881530643558e-10,0.3404174209557307,420.1654711943226,10.619887361658881,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-305Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.3,1.956224,1.972,0.992,72.0,8.72,45.4,8.32,36.7,0.00436872,-0.144826,47.7,1.8293785791513117,8.720003209762734,1.4539658450429115e-10,0.36801221079680607,999999.5873802284,6.600396896294549,-0.4257,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-305QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,274.3,1.956224,1.972,0.992,72.0,8.72,45.4,8.32,36.7,0.00436872,-0.144826,47.7,1.8293785791513117,8.720003209762734,1.4539658450429115e-10,0.36801221079680607,999999.5873802284,6.600396896294549,-0.4257,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-305W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,305.0,277.9,1.956224,1.972,0.992,72.0,8.81,45.0,8.29,36.8,0.004405000000000001,-0.135,45.8,1.791529404249954,8.817137848966421,1.0747881530643558e-10,0.3404174209557307,420.1654711943226,10.619887361658881,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-310T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.3,1.966,1.966,1.0,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-310TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.3,1.966,1.966,1.0,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-0-310TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.3,1.966,1.966,1.0,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-310T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.3,1.966,1.966,1.0,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-310TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.3,1.966,1.966,1.0,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HA-4-310TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.3,1.966,1.966,1.0,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-310T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.4,1.932528,1.956,0.988,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-310TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.4,1.932528,1.956,0.988,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-0-310TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.4,1.932528,1.956,0.988,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-310T,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.4,1.932528,1.956,0.988,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-310TB,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.4,1.932528,1.956,0.988,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72M6-HB-4-310TW,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,310.0,276.4,1.932528,1.956,0.988,72.0,8.77,45.7,8.33,37.2,0.0042973,-0.145783,47.9,1.9028042557487144,8.792072415311551,3.2625599466623724e-10,0.34746746148965496,999999.9846785566,13.714460834017453,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-310T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,277.9,1.9148999999999998,1.95,0.982,72.0,8.85,45.7,8.43,36.8,0.00531,-0.16452,46.8,1.933465409173248,8.850003158581025,4.806394720187539e-10,0.3566781144293422,999999.8287550386,3.702582462801374,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-310TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,277.9,1.9148999999999998,1.95,0.982,72.0,8.85,45.7,8.43,36.8,0.00531,-0.16452,46.8,1.933465409173248,8.850003158581025,4.806394720187539e-10,0.3566781144293422,999999.8287550386,3.702582462801374,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-310,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,282.4,1.9148999999999998,1.95,0.982,72.0,8.91,45.2,8.48,36.6,0.005346,-0.1356,46.6,1.7813804028790148,8.91000336299071,8.516662490397397e-11,0.37738636002710574,999999.943288992,8.304880803816177,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-310T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,277.9,1.9148999999999998,1.95,0.982,72.0,8.85,45.7,8.43,36.8,0.00531,-0.16452,46.8,1.933465409173248,8.850003158581025,4.806394720187539e-10,0.3566781144293422,999999.8287550386,3.702582462801374,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-310TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,277.9,1.9148999999999998,1.95,0.982,72.0,8.85,45.7,8.43,36.8,0.00531,-0.16452,46.8,1.933465409173248,8.850003158581025,4.806394720187539e-10,0.3566781144293422,999999.8287550386,3.702582462801374,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-310W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,282.4,1.9148999999999998,1.95,0.982,72.0,8.91,45.2,8.48,36.6,0.005346,-0.1356,46.6,1.7813804028790148,8.91000336299071,8.516662490397397e-11,0.37738636002710574,999999.943288992,8.304880803816177,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-310,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,280.5,1.956224,1.972,0.992,72.0,8.91,45.1,8.36,37.1,0.00515889,-0.18838270000000001,46.3,1.8888322423645196,8.91689670827456,3.753875576230795e-10,0.2851727738686647,368.4206516734403,-12.46927056788178,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-310,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,282.6,1.956224,1.972,0.992,72.0,8.91,45.1,8.36,37.1,0.004455,-0.1353,45.8,1.8039712558155694,8.918813963869212,1.2179475216231453e-10,0.30662260743817865,309.96355403229956,11.652633400800454,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-310Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,278.9,1.956224,1.972,0.992,72.0,8.87,45.6,8.41,36.9,0.004443869999999999,-0.145464,47.7,1.8333045310482246,8.870153647120235,1.3982142289501733e-10,0.38867216790675657,22438.03039926424,6.119950557222687,-0.4257,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-310QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,278.9,1.956224,1.972,0.992,72.0,8.87,45.6,8.41,36.9,0.004443869999999999,-0.145464,47.7,1.8333045310482246,8.870153647120235,1.3982142289501733e-10,0.38867216790675657,22438.03039926424,6.119950557222687,-0.4257,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-310W,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,310.0,282.6,1.956224,1.972,0.992,72.0,8.91,45.1,8.36,37.1,0.004455,-0.1353,45.8,1.8039712558155694,8.918813963869212,1.2179475216231453e-10,0.30662260743817865,309.96355403229956,11.652633400800454,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-315T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,282.6,1.9148999999999998,1.95,0.982,72.0,8.9,45.8,8.52,37.0,0.00534,-0.16487999999999997,46.8,1.9454552238700704,8.900002785118266,5.311368420257343e-10,0.3127422906725475,999992.134952956,4.496598777662303,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-0-315TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,282.6,1.9148999999999998,1.95,0.982,72.0,8.9,45.8,8.52,37.0,0.00534,-0.16487999999999997,46.8,1.9454552238700704,8.900002785118266,5.311368420257343e-10,0.3127422906725475,999992.134952956,4.496598777662303,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-315T,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,282.6,1.9148999999999998,1.95,0.982,72.0,8.9,45.8,8.52,37.0,0.00534,-0.16487999999999997,46.8,1.9454552238700704,8.900002785118266,5.311368420257343e-10,0.3127422906725475,999992.134952956,4.496598777662303,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PB-4-315TW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,282.6,1.9148999999999998,1.95,0.982,72.0,8.9,45.8,8.52,37.0,0.00534,-0.16487999999999997,46.8,1.9454552238700704,8.900002785118266,5.311368420257343e-10,0.3127422906725475,999992.134952956,4.496598777662303,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-315,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,285.2,1.956224,1.972,0.992,72.0,9.02,45.3,8.45,37.3,0.00522258,-0.1892181,46.3,1.8999824756619752,9.02786668080892,3.9273216594659574e-10,0.2777014141655261,318.414735246823,-12.231717194150653,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-315Q,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,283.6,1.956224,1.972,0.992,72.0,9.02,45.7,8.48,37.2,0.00451902,-0.145783,47.7,1.8513588337995908,9.027333447671245,1.6985759278162214e-10,0.3524660600914828,433.52653592604554,7.686018062057999,-0.4257,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-315QW,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,315.0,283.6,1.956224,1.972,0.992,72.0,9.02,45.7,8.48,37.2,0.00451902,-0.145783,47.7,1.8513588337995908,9.027333447671245,1.6985759278162214e-10,0.3524660600914828,433.52653592604554,7.686018062057999,-0.4257,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-320,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,320.0,289.8,1.956224,1.972,0.992,72.0,9.1,45.6,8.52,37.6,0.0052689,-0.1904712,46.3,1.9148329056265736,9.108140442933058,4.07219367385195e-10,0.26963544513206783,301.4188404998732,-12.035252708926208,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-325,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,325.0,294.5,1.956224,1.972,0.992,72.0,9.19,45.8,8.6,37.8,0.00532101,-0.1913066,46.3,1.9248598485955266,9.19840990988057,4.193272900884674e-10,0.2632528504923644,287.67181020879025,-11.895207607668414,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd HSL72P6-PC-3-330,Hanwha Qcells (Qidong) Co Ltd,Multi-c-Si,0,330.0,299.2,1.956224,1.972,0.992,72.0,9.28,46.0,8.69,38.0,0.0053731199999999995,-0.192142,46.3,1.9336091680037601,9.287987797358577,4.2552450713764026e-10,0.25723562110325465,298.84919429820866,-11.861758258791484,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G51G 330,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,330.0,300.9,1.94,,,72.0,9.41,45.6,8.83,37.4,0.0049187952,-0.14780784,45.7,1.8478146451660482,9.418852059730174,1.7781245008315172e-10,0.30181118652405975,320.8340887163538,5.981368884474922,-0.41812,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G52G 330,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,330.0,301.0,1.98,,,72.0,9.29,45.7,8.76,37.7,0.004320407399999999,-0.15559479,45.6,1.8438898303590272,9.295226824131072,1.585446332836866e-10,0.28009301445289686,497.82894617095144,0.09711808709142819,-0.41625,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G51G 335,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,335.0,305.6,1.94,,,72.0,9.47,45.8,8.91,37.6,0.004950158400000001,-0.14845611999999997,45.7,1.8543211608175234,9.476899813722042,1.7571757752801963e-10,0.2967996312484092,407.3577696681248,5.816376946522955,-0.41812,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G52G 335,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,335.0,305.7,1.98,,,72.0,9.35,46.0,8.84,37.9,0.004348311,-0.1566162,45.6,1.852102482101644,9.353513115852028,1.5196802083013653e-10,0.2867726839271892,763.2327211942021,-0.3053769777649921,-0.41625,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G51G 340,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,340.0,310.3,1.94,,,72.0,9.48,46.1,8.93,38.1,0.004955385600000001,-0.14942854,45.7,1.872292016955335,9.485721235007931,1.9008405588884902e-10,0.26534975613485007,439.6805794291006,6.477694093039522,-0.41812,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G52G 340,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,340.0,310.4,1.98,,,72.0,9.41,46.1,8.91,38.2,0.0043762146,-0.15695667,45.6,1.8606144445625483,9.41256151822386,1.6257003696880136e-10,0.2572514610466783,945.0397938721763,0.1821210351681165,-0.41625,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G51G 345,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,345.0,315.0,1.94,,,72.0,9.49,46.2,8.94,38.6,0.0049606128,-0.14975268,45.7,1.887732083189194,9.49494467877817,2.2049799163778867e-10,0.21114031209705728,405.22788544949,7.7539117005870715,-0.41812,N,2025.7.3,6/23/2025,4.0,first_pass +Hanwha Qcells (Qidong) Co Ltd QPRIME L-G52G 345,Hanwha Qcells (Qidong) Co Ltd,Mono-c-Si,0,345.0,315.1,1.98,,,72.0,9.46,46.3,8.99,38.4,0.004399467600000001,-0.15763760999999998,45.6,1.8649611212624833,9.460005682941983,1.5630788599459138e-10,0.25337518209536564,421763.75125857664,-0.19206113822045828,-0.41625,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-C265RG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,243.4,1.63,,,55.0,8.95,37.98,8.4,31.6,0.00264025,-0.1052046,45.7,1.4486302678354295,8.95952552366329,3.608571254811751e-11,0.228169053958534,214.3832852702784,9.925663792051688,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-C270RG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,270.0,248.1,1.63,,,55.0,9.05,38.08,8.52,31.72,0.0026697500000000002,-0.1054816,45.7,1.4510845377190456,9.05768739284886,3.5728496696489805e-11,0.22161397158681265,260.8955350581039,9.726119234473854,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-C275RG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,275.0,252.8,1.63,,,55.0,9.15,38.18,8.64,31.84,0.0026992500000000003,-0.10575860000000002,45.7,1.4535917108361323,9.155924871374067,3.540397618972959e-11,0.21521764730935103,332.3686511304303,9.535498011300758,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-C280RG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,280.0,257.5,1.63,,,55.0,9.25,38.28,8.77,31.96,0.00272875,-0.10603560000000002,45.7,1.4553279608580074,9.25358427180822,3.463925329042918e-11,0.20911234632652595,539.6602793158617,9.229425147027044,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-C285RG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,285.0,262.3,1.63,,,55.0,9.35,38.38,8.89,32.08,0.00275825,-0.10631260000000002,45.7,1.4579470731738153,9.351982765468488,3.4385218161129674e-11,0.20301651782992536,957.3520162956515,9.057681749685813,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350XG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,326.9,1.82,,,60.0,11.06,40.3,10.42,33.6,0.0030857400000000004,-0.10095149999999999,45.13,1.4442239226015268,11.071587739552664,8.270108785237512e-12,0.20810507461120023,198.62736137540494,6.1399819824978765,-0.3345,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350YG,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,328.0,1.82,,,60.0,11.06,40.3,10.42,33.6,0.00495488,-0.10812489999999998,43.3,1.5032384630639417,11.069719404476128,2.4777730694938526e-11,0.19547584428735543,222.43776508468255,8.043446971750976,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350YG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,325.5,1.82,,,60.0,11.06,40.3,10.42,33.6,0.00528668,-0.1098175,45.4,1.5090414203325004,11.069544534739553,2.747336711797203e-11,0.1942440833724521,225.085824726285,7.219739960284379,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355XG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,331.7,1.82,,,60.0,11.13,40.6,10.49,33.9,0.0031052700000000003,-0.101703,45.13,1.455758981940071,11.141137342719665,8.451127127562909e-12,0.20292319555366595,202.789409971059,6.271321235123927,-0.3345,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355YG,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,332.8,1.82,,,60.0,11.13,40.6,10.49,33.9,0.00498624,-0.10892980000000001,43.3,1.5152820071567585,11.139305684550962,2.53217079843615e-11,0.1902576994334544,227.5564146455681,8.177181030717977,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355YG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,330.2,1.82,,,60.0,11.13,40.6,10.49,33.9,0.005320140000000001,-0.11063500000000001,45.4,1.5211371388639525,11.139134386627173,2.807769129929556e-11,0.1890219433372105,230.31806278317984,7.352831876902865,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360XG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,336.5,1.82,,,60.0,11.2,41.0,10.56,34.1,0.0031247999999999996,-0.102705,45.13,1.4670228139758128,11.211489372207712,8.027374035987486e-12,0.21818035768989633,212.68525113807777,5.770057309573672,-0.3345,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,337.6,1.82,,,60.0,11.2,41.0,10.56,34.1,0.0050176,-0.110003,43.3,1.52686705736157,11.209582066236111,2.404868202092634e-11,0.2055681497184979,240.27837425011452,7.668496282042469,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360YG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,335.0,1.82,,,60.0,11.2,41.0,10.56,34.1,0.0053536,-0.11172500000000002,45.4,1.5327460447370633,11.209403621463538,2.6662427366838097e-11,0.2043392053953749,243.3742288854443,6.846883477575762,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365XG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,341.3,1.82,,,60.0,11.28,41.3,10.64,34.3,0.00314712,-0.10345649999999999,45.13,1.4764204197981852,11.291411195093147,7.887758987087517e-12,0.22356442554049225,220.99409276419053,5.555322266670065,-0.3345,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365YG,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,342.4,1.82,,,60.0,11.28,41.3,10.64,34.3,0.00505344,-0.11080789999999999,43.3,1.5365877079999783,11.289479791914255,2.362905719359422e-11,0.21099401357254402,251.061681164061,7.450740111702787,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365YG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,339.8,1.82,,,60.0,11.28,41.3,10.64,34.3,0.00539184,-0.1125425,45.4,1.542495134205561,11.289299131517643,2.619566822932135e-11,0.20976982206706415,254.4542587299235,6.630328559697999,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370XG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,346.1,1.82,,,60.0,11.35,41.5,10.71,34.6,0.00316665,-0.10395750000000001,45.13,1.4861231108696897,11.36065663142876,8.327979350468285e-12,0.20897936900913705,222.576483391854,5.969397852843904,-0.3345,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370YG,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,347.2,1.82,,,60.0,11.35,41.5,10.71,34.6,0.0050848,-0.1113445,43.3,1.5468066332575996,11.358813585394905,2.4952946624518638e-11,0.19634923640267288,252.85553536469786,7.871963017228011,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370YG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,344.6,1.82,,,60.0,11.35,41.5,10.71,34.6,0.0054253,-0.11308750000000002,45.4,1.5527702184713417,11.358641422777803,2.766626327758101e-11,0.1951181024789799,256.27614138266387,7.049237612711311,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375XG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,350.9,1.82,,,60.0,11.42,41.8,10.78,34.8,0.00318618,-0.104709,45.13,1.4955589775243463,11.430618012279709,8.181910388648166e-12,0.21453937890990635,230.7437258912322,5.761658757277501,-0.3345,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375YG,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,352.0,1.82,,,60.0,11.42,41.8,10.78,34.8,0.00511616,-0.11214939999999998,43.3,1.5565678726335601,11.428750274722322,2.4513543694172543e-11,0.2019382637547796,263.5500103969289,7.661129467642196,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375YG(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,349.4,1.82,,,60.0,11.42,41.8,10.78,34.8,0.00545876,-0.113905,45.4,1.5625615771690828,11.428575820022628,2.717815135836772e-11,0.20071033687225695,267.2761387317732,6.839753120332387,-0.3509,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,385.0,359.6,1.997112,,,66.0,11.04,44.5,10.4,37.1,0.00293664,-0.1055095,46.2,1.5579384636242788,11.052790954037528,4.265480944006068e-12,0.23838694277183134,205.75414814712022,6.3044189131835955,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,385.0,361.9,2.0,,,66.0,11.04,44.5,10.4,37.1,0.00321264,-0.1045305,44.51,1.55403314873456,11.052914049421279,3.969600900794815e-12,0.23923828171963976,204.52068252115185,6.638579044410863,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,390.0,364.4,1.997112,,,66.0,11.11,44.8,10.47,37.3,0.0029552599999999995,-0.10622079999999999,46.2,1.5671628522765646,11.122780926582571,4.196075587035896e-12,0.24395792339646394,212.06385276929933,6.1042462132123525,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,390.0,366.7,2.0,,,66.0,11.11,44.8,10.47,37.3,0.0032330099999999997,-0.10523519999999999,44.51,1.5632389310140193,11.122905348934776,3.9051028159074994e-12,0.24480671809937504,210.75002743107146,6.437639499468822,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395OF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,369.1,1.95,,,54.0,13.18,37.2,12.45,31.7,0.0043494,-0.08928000000000001,46.82,1.3158268241724222,13.188651708298314,6.8293302026357885e-12,0.10405574824620599,158.51837772319564,7.470102175611053,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,369.2,1.997112,,,66.0,11.18,45.0,10.54,37.5,0.00297388,-0.106695,46.2,1.5745524318200799,11.192405232061564,4.254325027640729e-12,0.23990981383605456,216.21455428247123,6.168014507454605,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,371.5,2.0,,,66.0,11.18,45.0,10.54,37.5,0.00325338,-0.10570500000000001,44.51,1.5706089213749224,11.192528207696077,3.959306411228525e-12,0.24075763018279245,214.8487933392184,6.50176311716837,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400OF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,373.9,1.95,,,54.0,13.29,37.3,12.56,31.8,0.0043857,-0.08952,46.82,1.3193556467013097,13.29835129559972,6.888725775296586e-12,0.10218688616718566,162.61712965069844,7.470966558932573,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,373.9,2.0,,,66.0,11.25,45.3,10.61,37.7,0.0029925,-0.1064097,46.2,1.5832779192495001,11.262392081592868,4.148516167793888e-12,0.24550327002590258,222.8771437407479,6.888495280346074,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,376.3,2.0,,,66.0,11.25,45.3,10.61,37.7,0.00327375,-0.1064097,44.51,1.5798173105363276,11.262500694215799,3.896120089629572e-12,0.24624162155282442,221.60514907658552,6.304420444265508,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405OF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,378.6,1.95,,,54.0,13.41,37.4,12.68,31.9,0.0044253,-0.08975999999999999,46.82,1.3032853759461267,13.418652707212267,4.542548158001143e-12,0.1038402112749219,160.9319719751308,3.790529526758523,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,378.7,1.997112,,,66.0,11.33,45.6,10.69,37.9,0.0030137799999999998,-0.10811760000000001,46.2,1.592969724146732,11.342293889711632,4.12150706586763e-12,0.2505915676660994,230.94415160248548,5.771895004718906,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,381.1,2.0,,,66.0,11.33,45.6,10.69,37.9,0.00329703,-0.1071144,44.51,1.5889890285705688,11.34241951810431,3.835869627331396e-12,0.2514336031776784,229.3762611553094,6.104185347273389,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410OF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,410.0,383.4,1.95,,,54.0,13.53,37.5,12.8,32.0,0.0044649,-0.09,46.82,1.326370471935434,13.537731993156113,7.012125750987787e-12,0.09840628751512286,172.19842871097407,7.465014885043596,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,410.0,383.5,1.997112,,,66.0,11.4,45.9,10.76,38.1,0.0030323999999999998,-0.1088289,46.2,1.602199941223217,11.412226663511575,4.057626402290156e-12,0.25593220692171703,238.62823741559657,5.580828511521705,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S410YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,410.0,386.0,2.0,,,66.0,11.4,45.9,10.76,38.1,0.0033174000000000003,-0.1078191,44.51,1.5982003543319296,11.412353667133596,3.776488201271838e-12,0.25677184265808156,236.94980433665202,5.912473684356048,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S415OF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,415.0,388.2,1.95,,,54.0,13.65,37.6,12.93,32.1,0.004504500000000001,-0.09024,46.82,1.32940082985259,13.65699681343671,7.008654643409926e-12,0.09665217954164138,188.55758625805126,7.3770231086707305,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S415XH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,415.0,388.3,2.0,,,66.0,11.47,46.1,10.83,38.4,0.00305102,-0.10828890000000001,46.2,1.6110729204612426,11.481524479570187,4.222564649279382e-12,0.24149594632593369,240.3543116158163,6.8684957855362265,-0.3183,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S415YH(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,415.0,390.8,2.0,,,66.0,11.47,46.1,10.83,38.4,0.0033377700000000003,-0.10828890000000001,44.51,1.60755268123677,11.481631217140391,3.9657165193795034e-12,0.24223204720003957,238.87453496530946,6.284652836817242,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T420NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,420.0,398.1,1.94,,,54.0,14.11,38.0,13.34,31.5,0.0049385,-0.09043999999999999,43.7,1.304323346821083,14.12443829272949,3.094065501131645e-12,0.17828783894303762,174.23399441652865,0.9443393746553765,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,420.0,393.8,2.17,,,72.0,11.04,48.6,10.4,40.4,0.00283728,-0.10993320000000002,45.6,1.6766848351290837,11.053950639341192,2.7950970806440605e-12,0.27819654768727387,220.15405993717096,7.662288709722419,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,420.0,393.4,2.17,,,72.0,11.04,48.6,10.4,40.4,0.004934879999999999,-0.1283526,44.0,1.7887528523755634,11.050744115839109,1.7231809456535865e-11,0.25400376668299607,260.9988242384386,6.607888516084634,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T425NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,402.9,1.94,,,54.0,14.18,38.2,13.41,31.7,0.004963,-0.09091600000000001,43.7,1.3116856136940014,14.194031681103347,3.144687618224033e-12,0.1754413062303748,177.29577141744332,1.0375970624615785,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S425XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,398.6,2.17,,,72.0,11.11,48.8,10.47,40.6,0.00285527,-0.1103856,45.6,1.6839453535501465,11.123569264324685,2.8313966515007863e-12,0.2739268389857505,224.28092719900454,7.719045008252471,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S425YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,398.2,2.17,,,72.0,11.11,48.8,10.47,40.6,0.004966169999999999,-0.1288808,44.0,1.796533671362553,11.120398733143995,1.745803891044112e-11,0.24977163612187742,266.85586177286604,6.664699443217636,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T425NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,401.9,1.94,,,54.0,13.67,39.29,13.12,32.41,0.0045111000000000005,-0.08734167000000001,46.03,1.296946064863116,13.670002826560573,9.531133125502293e-13,0.2067672924807283,999984.3608987345,-1.764271441195941,-0.2767,N,2025.7.3,6/23/2025,2.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T430NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,407.8,1.94,,,54.0,14.25,38.4,13.48,31.9,0.004987500000000001,-0.091392,43.7,1.3190469962083544,14.263633426161348,3.1955973919854777e-12,0.17262499927509486,180.43199220715903,1.1297018209407823,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S430XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,403.4,2.17,,,72.0,11.18,49.0,10.54,40.8,0.00287326,-0.110838,45.6,1.6912064460344276,11.193195345229544,2.8679148255447065e-12,0.2697140040024279,228.52017222443232,7.775415575961194,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S430YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,403.0,2.17,,,72.0,11.18,49.0,10.54,40.8,0.00499746,-0.129409,44.0,1.8043150807217614,11.190060803311942,1.7685636987977357e-11,0.24559588643632332,272.91677836303006,6.721112955369552,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T430NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,406.8,1.94,,,54.0,13.83,39.49,13.23,32.51,0.0045639,-0.08778627,46.03,1.3023794919187752,13.831825425330573,9.368989796001424e-13,0.21556399013856223,1633.181017264714,-1.99527813379595,-0.2767,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T435NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,412.6,1.94,,,54.0,14.32,38.6,13.56,32.1,0.005012,-0.09186799999999999,43.7,1.3259724306100815,14.332427125796599,3.218704798565575e-12,0.1698507976886702,195.7221210863324,1.144676356721577,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,408.2,2.17,,,72.0,11.25,49.2,10.61,41.0,0.00289125,-0.11129040000000001,45.6,1.698468099229065,11.262828755785257,2.9046506189500504e-12,0.2655569150452272,232.8764370636901,7.8314044938882805,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,407.8,2.17,,,72.0,11.25,49.2,10.61,41.0,0.005028749999999999,-0.1299372,44.0,1.7920638900124153,11.250008086980257,1.3423391712058798e-11,0.24534052385528013,341301.39760317816,4.248310780096618,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T435NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,411.6,1.94,,,54.0,13.91,39.69,13.29,32.74,0.0045903,-0.08823086999999999,46.03,1.3107998138099821,13.913577954898116,9.813375815366255e-13,0.20989371403141077,816.0028862926523,-1.6533455342440462,-0.2767,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T440NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,417.5,1.94,,,54.0,14.39,38.8,13.63,32.3,0.0050365,-0.09234399999999998,43.7,1.3333314566903969,14.402059834903762,3.269860069199559e-12,0.1670956886384904,199.38141655376123,1.2348730590494592,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S440XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,413.0,2.17,,,72.0,11.33,49.4,10.69,41.2,0.00291181,-0.1117428,45.6,1.7056899168321529,11.342436691561323,2.9423652034963472e-12,0.2612261628323407,237.98068869722502,7.881201375924785,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S440YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,412.6,2.17,,,72.0,11.33,49.4,10.69,41.2,0.0050645099999999995,-0.130416,44.0,1.8002402602014262,11.33001013171964,1.3703868940697828e-11,0.24096055543532421,269460.3011238288,4.403378016492437,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T440NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,416.5,1.94,,,54.0,14.06,39.9,13.41,32.82,0.0046398,-0.0886977,46.03,1.3170248510251075,14.065789930336177,9.7414512157491e-13,0.21667573714163238,526.1653780095396,-1.79557916888318,-0.2767,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T445NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,422.3,1.94,,,54.0,14.46,39.0,13.7,32.5,0.005124624,-0.0926679,43.7,1.884747498075817,14.460071353634811,9.990007371998942e-14,2.3486890903292306,525194.7974883369,99.9999606948976,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S445XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,417.8,2.17,,,72.0,11.4,49.6,10.76,41.4,0.0029298,-0.11219520000000002,45.6,1.6920611367134542,11.400009345745788,2.119669136381792e-12,0.26125801895338013,318684.53682486387,4.873944136291741,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S445YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,417.4,2.17,,,72.0,11.4,49.6,10.76,41.4,0.0050958,-0.13099360000000002,44.0,1.8084441151721231,11.400009674488507,1.3981409077348472e-11,0.23685053466206316,279095.84659417707,4.481512492069635,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T445NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,421.3,1.94,,,54.0,14.14,40.1,13.47,33.05,0.0046662000000000006,-0.08914230000000001,46.03,1.3254534190877827,14.14746037342899,1.0198422351987679e-12,0.21107272947063555,400.05616706271286,-1.456623035627126,-0.2767,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T450NF(BK),HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,427.2,1.94,,,54.0,14.53,39.2,13.77,32.7,0.005149431999999999,-0.09314312,43.7,1.3491636239339446,14.541301633028386,3.455291924033593e-12,0.16148670480014607,207.61617559522045,1.7751045826699454,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S450XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,422.6,2.17,,,72.0,11.47,49.8,10.83,41.6,0.0029477900000000005,-0.1126476,45.6,1.6996505597023401,11.470007748609333,2.161073168458611e-12,0.257180888666376,380696.5174310101,4.988635063180062,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S450YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,422.2,2.17,,,72.0,11.47,49.8,10.83,41.6,0.00512709,-0.1315218,44.0,1.816606667755044,11.470007054724535,1.4253404105569407e-11,0.23280215058194495,378506.4238953888,4.593198441123982,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,455.0,427.4,2.17,,,72.0,11.54,50.0,10.9,41.8,0.00296578,-0.1131,45.6,1.7072411613460718,11.54000731424397,2.2029859700861293e-12,0.2531559946873792,399415.74020847585,5.102577801942907,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455YI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,455.0,427.0,2.17,,,72.0,11.54,50.0,10.9,41.8,0.005158379999999999,-0.132,44.0,1.8431483754092115,11.54844974562709,1.8838605352901495e-11,0.22534244643051352,307.75504548216026,7.027919754031297,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S570OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,570.0,531.3,2.76,,,78.0,13.32,53.2,12.56,45.4,0.006260400000000001,-0.13087200000000002,47.19,1.9319422568653686,13.32834501592442,1.4364960944140718e-11,0.13240519541931658,211.34018463915282,11.098098951943067,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S575OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,575.0,536.1,2.76,,,78.0,13.38,53.4,12.63,45.5,0.0062886,-0.131364,47.19,1.9367455882562885,13.388159736725871,1.3953016935981178e-11,0.13887909629298378,227.72821924182003,10.788943172672761,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S580OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,580.0,540.9,2.76,,,78.0,13.45,53.5,12.7,45.7,0.006321500000000001,-0.13161,47.19,1.94246624268947,13.457511412439128,1.4451200711773599e-11,0.12816339090911588,229.49047561939082,11.05826812787496,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S585OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,585.0,545.7,2.76,,,78.0,13.51,53.7,12.76,45.8,0.0063497,-0.132102,47.19,1.9480134493836991,13.517728607807653,1.4174306475105595e-11,0.13444769949047933,235.02142636186719,10.841379310425564,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T590NI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,590.0,550.3,2.56,,,72.0,14.47,51.9,13.66,43.2,0.017653400000000003,-0.162447,43.1,2.2052997352716828,14.474219330812051,8.647421881903993e-10,0.15558281293282594,533.5642600458232,19.660164419435162,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S590OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,590.0,550.5,2.76,,,78.0,13.57,53.9,12.83,46.0,0.006377900000000001,-0.13259400000000002,47.19,1.9549037828645859,13.57708455668653,1.4180662705073177e-11,0.13191935770361105,252.68281078341857,10.8007532620801,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T595NI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,595.0,555.1,2.56,,,72.0,14.53,52.1,13.72,43.4,0.0177266,-0.163073,43.1,2.2144572101506044,14.534022374079875,8.746151699737362e-10,0.15271476218470068,551.6509111676769,19.73030931644296,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S595OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,595.0,555.3,2.76,,,78.0,13.64,54.0,12.89,46.1,0.006410800000000001,-0.13284,47.19,1.9592844023179714,13.647312532501607,1.4397318037890263e-11,0.13010514084159058,242.6839318265168,10.89359510476255,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T600NI,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,600.0,560.0,2.56,,,72.0,14.59,52.3,13.77,43.6,0.0177998,-0.163699,43.1,2.2244551065202782,14.594373802470576,8.916569786968766e-10,0.14974647027732058,499.51998221000554,19.88119114100316,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S600OJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,600.0,560.1,2.76,,,78.0,13.71,54.2,12.95,46.2,0.0064437,-0.133332,47.19,1.9655227138906703,13.717913476510056,1.4260003998646857e-11,0.13606272965165403,235.72699393432384,10.762524189970051,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T615NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,615.0,581.4,2.76,,,78.0,13.67,56.74,13.12,46.9,0.004142010000000001,-0.13214746,45.12,1.913451436557376,13.67000384664928,1.8094067332305444e-12,0.2813908176221921,999993.4759181459,-1.0516657399362568,-0.2937,N,2025.7.3,6/23/2025,2.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T620NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,620.0,586.2,2.76,,,78.0,13.75,56.95,13.18,47.07,0.004166250000000001,-0.13263655,45.12,1.9195316209400992,13.750003932725077,1.7920498798036062e-12,0.28601498435462536,999998.2434253048,-1.1789506437705697,-0.2937,N,2025.7.3,6/23/2025,2.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T625NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,625.0,591.0,2.76,,,78.0,13.82,57.15,13.24,47.24,0.0041874600000000005,-0.13310235,45.12,1.9259476561009872,13.820003969583645,1.7921758356857532e-12,0.2872334998463497,999998.9021809063,-1.2201140450984673,-0.2937,N,2025.7.3,6/23/2025,2.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T630NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,630.0,600.9,2.77,,,78.0,14.31,55.9,13.55,46.5,0.006207678,-0.12675325,43.5,1.8752844338462393,14.323842725656704,1.598524370457643e-12,0.25266191186894293,261.1907528998178,0.07752477312340549,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T630NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,630.0,595.9,2.76,,,78.0,13.9,57.36,13.29,47.41,0.0042117000000000005,-0.13359144,45.12,1.93376885292256,13.901786277643607,1.8201487246303457e-12,0.28895538228221385,2248.5194587207216,-1.1332265050940609,-0.2937,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T635NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,635.0,605.8,2.77,,,78.0,14.36,56.1,13.6,46.7,0.006229368000000001,-0.12720675,43.5,1.8824537790486648,14.373569750238936,1.6160968399977077e-12,0.24988244143251964,264.43462813673307,0.1392504235174891,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T635NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,635.0,600.7,2.76,,,78.0,13.98,57.56,13.35,47.57,0.0042359400000000005,-0.13405724,45.12,1.9414291358398073,13.983296533318255,1.8538334358486126e-12,0.28878210166425583,1224.672536992147,-1.0237231345492646,-0.2937,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T640NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,640.0,610.6,2.77,,,78.0,14.41,56.3,13.65,46.9,0.006251058,-0.12766025,43.5,1.8896225526022647,14.423300682672194,1.6337360874173034e-12,0.2471237462268171,267.73461615479334,0.20046281959742654,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T640NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,640.0,605.6,2.76,,,78.0,14.06,57.77,13.41,47.74,0.0042601800000000006,-0.13454633,45.12,1.9494588928171095,14.064813355932404,1.888810848819342e-12,0.2885134815411733,842.7591100530966,-0.9109881077867495,-0.2937,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T645NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,645.0,615.5,2.77,,,78.0,14.46,56.5,13.7,47.1,0.006272748000000001,-0.12811375000000003,43.5,1.89679074978742,14.473035467899468,1.6514413550186896e-12,0.24438559519561687,271.09235597805076,0.2611667577301211,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-T645NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,645.0,610.4,2.76,,,78.0,14.14,57.97,13.47,47.9,0.00428442,-0.13501213,45.12,1.9571190567696806,14.146333941802537,1.9232605282676436e-12,0.28834375075824203,643.703521540253,-0.8030572887656405,-0.2937,N,2025.7.3,6/23/2025,4.0,first_pass +HD HYUNDAI ENERGY SOLUTIONS CO LTD HiN-T650NJ,HD HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,650.0,620.4,2.77,,,78.0,14.51,56.7,13.75,47.3,0.006294438,-0.12856725000000002,43.5,1.9039584303131998,14.522774099522383,1.6692134828075325e-12,0.24166775072294716,274.5085121942591,0.3213756558633123,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 20M-100GH,Heliene,Mono-c-Si,0,100.0,85.2,1.62,,,20.0,9.73,13.3,9.2,11.16,0.0016346400000000001,-0.045020500000000005,46.0,0.6268685744446221,9.731936657415284,5.942375487870634e-09,0.03455474950649025,999999.7776938374,34.83030513652637,-0.587,Y,2025.7.3,6/23/2025,2.0,first_pass +Heliene 60P215,Heliene,Multi-c-Si,0,215.0,190.2,1.6632,1.68,0.99,60.0,8.1,36.5,7.6,28.6,0.0037910735826296744,-0.11536784741144414,47.2,1.5201128275948332,8.105474557725078,3.0055745782352656e-10,0.46644664927424107,690.1416208759766,14.8155868249044,-0.47733333333333333,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P220,Heliene,Multi-c-Si,0,220.0,194.8,1.6632,1.68,0.99,60.0,8.18,36.6,7.68,28.9,0.0038285162846803376,-0.11568392370572209,47.2,1.5304892195125421,8.185292641145738,3.3451053849043756e-10,0.42881838600111993,662.7572638127834,15.720140927836006,-0.47733333333333333,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P225,Heliene,Multi-c-Si,0,225.0,199.3,1.6632,1.68,0.99,60.0,8.29,36.7,7.74,29.2,0.0038799999999999993,-0.11600000000000002,47.2,1.5457805627834544,8.30096867991555,3.9951703141888946e-10,0.3906778769279158,295.2698469700214,17.289379876083448,-0.47733333333333333,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M230,Heliene,Mono-c-Si,0,230.0,207.1,1.6632,1.68,0.99,60.0,8.6,36.6,7.8,29.5,0.0013443678160919537,-0.11536956521739135,46.0,1.481814482031558,8.639222829016283,1.5291244565822163e-10,0.3427730227398554,75.15643674924002,9.047699593011314,-0.4429166666666667,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P230,Heliene,Multi-c-Si,0,230.0,203.9,1.6632,1.68,0.99,60.0,8.38,36.8,7.8,29.5,0.0039221230398069976,-0.11631607629427793,47.2,1.5592271780528524,8.393386848890069,4.6268516103984433e-10,0.3540162370708103,221.6097870137101,18.60015485178349,-0.47733333333333333,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M235,Heliene,Mono-c-Si,0,235.0,211.7,1.6632,1.68,0.99,60.0,8.69,36.7,7.9,29.75,0.001358436781609195,-0.11568478260869569,46.0,1.4888658286673213,8.725036134092566,1.6275393595422308e-10,0.3149899425012223,78.12684651268383,9.496142591817836,-0.4429166666666667,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M240,Heliene,Mono-c-Si,0,240.0,216.3,1.6632,1.68,0.99,60.0,8.7,36.8,8.0,30.0,0.0013599999999999999,-0.11600000000000002,46.0,1.488355427234787,8.72416111892496,1.5306004097698686e-10,0.29154385526576615,104.97989058047605,8.905548051604415,-0.4429166666666667,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P240,Heliene,Multi-c-Si,0,240.0,214.1,1.6412707998999998,1.6799087,0.977,60.0,8.55,37.55,7.91,30.34,0.0019665,-0.1130255,49.0,1.4853802265062825,8.57230665193198,8.705603344997563e-11,0.349107806064468,133.81083930757177,9.057431697072834,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M245,Heliene,Mono-c-Si,0,245.0,220.9,1.6632,1.68,0.99,60.0,8.71,37.26,8.18,30.03,0.0013615632183908047,-0.11745000000000003,46.0,1.4808468695735673,8.71899269785242,1.0173888248941781e-10,0.345912346522511,335.03815542571476,5.301360954985966,-0.4429166666666667,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P245,Heliene,Multi-c-Si,0,245.0,218.7,1.6412707998999998,1.6799087,0.977,60.0,8.6,37.65,8.05,30.43,0.0019779999999999997,-0.1133265,49.0,1.4806629934635025,8.61231590266715,7.656983666998722e-11,0.3468841768897587,242.22374292345552,7.841856885473446,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M250,Heliene,Mono-c-Si,0,250.0,225.6,1.6632,1.68,0.99,60.0,8.72,37.4,8.22,30.3,0.0013631264367816092,-0.11789130434782612,46.0,1.4878341417126684,8.725669639903504,1.0473708582315539e-10,0.32444826055129244,499.00684618865404,5.523277207970586,-0.4429166666666667,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P250,Heliene,Multi-c-Si,0,250.0,223.3,1.6412707998999998,1.6799087,0.977,60.0,8.65,37.8,8.14,30.7,0.0019895,-0.11377799999999999,49.0,1.4864956464233172,8.657615555198802,7.737213151725943e-11,0.3249588113433098,369.0990093368449,7.861355720639051,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M255,Heliene,Mono-c-Si,0,255.0,229.6,1.6632,1.68,0.99,60.0,8.86,37.5,8.32,30.65,0.0094802,-0.14024999999999999,46.1,1.6546480298799044,8.864418852955453,1.262636053060262e-09,0.24414522066546795,489.5225848943043,7.410573439128044,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60P255,Heliene,Multi-c-Si,0,255.0,227.9,1.6412707998999998,1.6799087,0.977,60.0,8.71,39.9,8.2,30.95,0.0020033000000000004,-0.120099,49.0,1.530557731742991,8.715826986297714,4.133186496455886e-11,0.5484760700136648,819.8452950776078,2.491255490135913,-0.425,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M260,Heliene,Mono-c-Si,0,260.0,234.2,1.6632,1.68,0.99,60.0,8.9,37.73,8.43,30.84,0.009523,-0.1411102,46.1,1.6583023641347834,8.915847631032793,1.1722303810397613e-09,0.24492858770529338,999999.9793434365,6.68592615069544,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 60P260,Heliene,Multi-c-Si,0,260.0,232.6,1.6153499999999998,1.65,0.979,60.0,9.0,38.0,8.56,30.71,0.00207,-0.11438,49.0,1.4850656695121893,9.000002952430435,6.941810856737277e-11,0.3279988079988244,999999.8428742102,6.547692210092942,-0.425,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72P260,Heliene,Multi-c-Si,0,260.0,229.6,1.952256,1.984,0.984,72.0,8.03,42.62,7.5,34.65,0.0022956352941176468,-0.13494256802338656,47.5,1.7998688411734223,8.039449087830103,4.1084514757816575e-10,0.3563271179988674,302.8130645493924,17.87225160555497,-0.48168822841624864,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M265,Heliene,Mono-c-Si,0,265.0,235.5,1.6632,1.68,0.99,60.0,9.0,38.4,8.5,31.17,0.00378,-0.136704,47.8,1.6184977217868393,9.001825536033609,4.457594194349117e-10,0.29237588807177556,1441.4317681524217,4.314405851441554,-0.471,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P265,Heliene,Multi-c-Si,0,265.0,234.1,1.952256,1.984,0.984,72.0,8.13,42.85,7.6,34.8,0.002324223529411765,-0.13567078929615473,47.5,1.807631223684687,8.139055647507886,4.059384621803468e-10,0.3596980682816186,322.9306158613458,17.636905510893627,-0.48168822841624864,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M270,Heliene,Mono-c-Si,0,270.0,244.1,1.5524529999999999,1.589,0.977,60.0,9.1,38.92,8.71,31.31,0.0056419999999999994,-0.1296036,46.5,1.6134181076643956,9.100002642535436,3.0386762212094925e-10,0.29021804557873077,999888.8894582808,7.82756825961585,-0.441,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72P270,Heliene,Multi-c-Si,0,270.0,238.7,1.952256,1.984,0.984,72.0,8.24,43.05,7.7,35.0,0.002355670588235294,-0.13630402518551835,47.5,1.8175489892336714,8.249347198469158,4.192173443096807e-10,0.3507481505606391,309.2012304904922,17.81659043187873,-0.48168822841624864,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M275,Heliene,Mono-c-Si,0,275.0,248.8,1.5524529999999999,1.589,0.977,60.0,9.18,39.07,8.78,31.62,0.0056916,-0.1301031,46.5,1.6236492934355045,9.180002471270301,3.253710042827691e-10,0.269073930391703,999997.0337650809,8.348375715059095,-0.441,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72P275,Heliene,Multi-c-Si,0,275.0,243.2,1.952256,1.984,0.984,72.0,8.27,43.36,7.8,35.25,0.0023642470588235293,-0.13728554081403194,47.5,1.8215676445866145,8.272876427459352,3.780998212492035e-10,0.35335150843699525,1015.9194169548331,16.76801187930776,-0.48168822841624864,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M280,Heliene,Mono-c-Si,0,280.0,253.5,1.5524529999999999,1.589,0.977,60.0,9.26,39.23,8.85,31.94,0.0057412,-0.1306359,46.5,1.6343371721818187,9.260002297927441,3.4831468420181816e-10,0.24804031592801296,999999.0105076035,8.870402747884263,-0.441,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M280,Heliene,Mono-c-Si,0,280.0,251.0,1.952256,1.984,0.984,72.0,8.35,44.16,7.8,35.9,0.0022055230386052306,-0.13756388261851016,47.5,1.767969654190359,8.362311350035249,1.1631702162176079e-10,0.38128261249434753,258.59958146297254,7.963891141790538,-0.43356695496570236,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M285,Heliene,Mono-c-Si,0,285.0,258.1,1.5524529999999999,1.589,0.977,60.0,9.34,39.38,8.92,32.24,0.0057908,-0.1311354,46.5,1.6443170134226266,9.340002136548007,3.709881863950793e-10,0.2286465231025358,999999.6510627009,9.350812299607181,-0.441,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M285,Heliene,Mono-c-Si,0,285.0,255.6,1.952256,1.984,0.984,72.0,8.45,44.4,7.9,36.1,0.002231936488169365,-0.1383115124153499,47.5,1.7769421174950122,8.461807108740786,1.1677625962940088e-10,0.3781501965618925,270.63097243695177,7.891566191924129,-0.43356695496570236,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P285,Heliene,Multi-c-Si,0,285.0,253.2,1.838103,1.893,0.971,72.0,8.41,44.79,7.82,38.61,0.005382400000000001,-0.15049440000000003,48.9,1.9583683259205937,8.411199834732333,9.54633735558888e-10,0.027343918424840467,191.661710193798,18.068697882238933,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M290,Heliene,Mono-c-Si,0,290.0,262.8,1.5524529999999999,1.589,0.977,60.0,9.42,39.6,8.99,32.45,0.0058404,-0.131868,46.5,1.6536632411090795,9.420002144173012,3.7503437943977173e-10,0.22751345212376017,999999.8110271926,9.3713140369064,-0.441,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M290,Heliene,Mono-c-Si,0,290.0,260.2,1.952256,1.984,0.984,72.0,8.56,44.65,8.0,36.25,0.002260991282689913,-0.13909029345372462,47.5,1.7858213928105258,8.57239989126754,1.1641724627364292e-10,0.38316666147667505,264.5109310978531,7.753898500926751,-0.43356695496570236,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P290,Heliene,Multi-c-Si,0,290.0,257.8,1.838103,1.893,0.971,72.0,8.49,44.92,7.9,38.73,0.0054336,-0.15093120000000002,48.9,1.963465506078536,8.491141046192752,9.579459667663508e-10,0.02636619971558959,196.178787240409,18.008252495566293,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M295,Heliene,Mono-c-Si,0,295.0,266.1,1.602623,1.637,0.979,60.0,9.507,39.679,9.058,32.838,0.00541899,-0.12181453,48.0,1.6271176305969215,9.507001967144843,2.439536494755184e-10,0.20685437550969676,999999.9774748315,14.631442146641904,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M295,Heliene,Mono-c-Si,0,295.0,264.8,1.952256,1.984,0.984,72.0,8.67,44.77,8.1,36.4,0.002290046077210461,-0.13946410835214448,47.5,1.792379468432059,8.682665468462698,1.2077229688549426e-10,0.3716987137575296,254.44206923988483,7.96322188740391,-0.43356695496570236,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M300,Heliene,Mono-c-Si,0,300.0,270.8,1.602623,1.637,0.979,60.0,9.59,39.83,9.127,33.139,0.0054663,-0.1222781,48.0,1.6353638816088463,9.602965551169508,2.5408100864433604e-10,0.19474809414456462,999999.9815950427,14.916105738678395,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M300,Heliene,Mono-c-Si,0,300.0,269.4,1.952256,1.984,0.984,72.0,8.77,44.96,8.2,36.55,0.0023164595267745956,-0.14005598194130928,47.5,1.799114687169928,8.782190420476113,1.2081286645499652e-10,0.36971347974530094,265.97830541747345,7.86350652720712,-0.43356695496570236,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P300,Heliene,Multi-c-Si,0,300.0,267.0,1.838103,1.893,0.971,72.0,8.65,45.3,8.19,36.91,0.005536000000000001,-0.15220799999999998,48.9,1.8982151656888393,8.650355419467353,3.737060073915338e-10,0.3422822077279044,8330.305640969093,9.084379949106754,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 60M305,Heliene,Mono-c-Si,0,305.0,273.9,1.904,,,,9.45,39.49,9.03,32.51,0.005386500000000001,-0.1212343,48.0,1.617624713857492,9.450002034367177,2.3620372640904326e-10,0.21521397953875276,999999.6675771257,14.388650540654513,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M305,Heliene,Mono-c-Si,0,305.0,269.5,1.952256,1.984,0.984,72.0,8.86,45.1,8.32,36.65,0.0036326,-0.156046,50.1,1.856308749856977,8.867424852084989,2.461168590701396e-10,0.35520729161430464,423.8652575244399,2.4982297142210608,-0.446,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P305,Heliene,Multi-c-Si,0,305.0,271.6,1.838103,1.893,0.971,72.0,8.73,45.51,8.29,37.06,0.0055872000000000005,-0.1529136,48.9,1.9057058440529544,8.751751053813718,3.7217133908179503e-10,0.3429783693665473,999999.9845334144,8.945004832951115,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 60M-310,Heliene,Mono-c-Si,0,310.0,282.3,1.6517,,,60.0,9.96,39.58,9.27,33.54,0.0037399800000000004,-0.107851542,49.06,1.5306824863728328,9.970687518925617,5.6899948196455946e-11,0.13681245208969856,127.49937973808542,14.874525253499272,-0.37555,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M310,Heliene,Mono-c-Si,0,310.0,274.1,1.952256,1.984,0.984,72.0,8.9,45.4,8.43,36.77,0.0036490000000000003,-0.157084,50.1,1.856689873285074,8.900423378421097,2.1365289382191643e-10,0.37389927619716706,7859.899393138378,1.2690561658074473,-0.446,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P310,Heliene,Multi-c-Si,0,310.0,276.2,1.838103,1.893,0.971,72.0,8.81,45.66,8.4,37.2,0.005638400000000001,-0.1534176,48.9,1.9186538784069367,8.810002701304072,4.0706335175911607e-10,0.3064753328216516,999999.8688550774,9.677054023286326,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 60M-315,Heliene,Mono-c-Si,0,315.0,287.0,1.6517,,,60.0,10.22,40.01,9.33,33.9,0.0038376100000000004,-0.109023249,49.06,1.5633596607802,10.238423724495103,7.440622620461353e-11,0.13092309424136025,72.62559917328556,17.227026875562128,-0.37555,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M315,Heliene,Mono-c-Si,0,315.0,279.6,1.838103,1.893,0.971,72.0,9.16,45.31,8.53,37.19,0.0056792,-0.15405400000000002,49.0,1.9463045630140725,9.171129444724158,6.959318772737468e-10,0.2781842464139255,228.9573461258437,12.91878188870821,-0.461,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P315,Heliene,Multi-c-Si,0,315.0,280.8,1.838103,1.893,0.971,72.0,8.89,45.81,8.5,37.33,0.0056896,-0.15392160000000002,48.9,1.9277261917617645,8.89000256644358,4.2504498381977564e-10,0.2885553964573722,999998.8950147298,9.980908838537806,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 60M-320,Heliene,Mono-c-Si,0,320.0,291.7,1.6517,,,60.0,10.09,40.09,9.38,34.17,0.003788795,-0.10924124100000002,49.06,1.556144900633394,10.099368598458897,6.328880168276143e-11,0.1121941489310823,120.83333231352319,15.749919744256843,-0.37555,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M320,Heliene,Mono-c-Si,0,320.0,284.2,1.838103,1.893,0.971,72.0,9.2,45.69,8.61,37.48,0.005704,-0.155346,49.0,1.9565812765923751,9.208051756076236,6.543828036803194e-10,0.2832401214147542,323.6324700806666,12.298445908479453,-0.461,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P320,Heliene,Multi-c-Si,0,320.0,285.4,1.838103,1.893,0.971,72.0,8.97,45.96,8.65,37.42,0.0057408,-0.15442560000000002,48.9,1.9418980888884105,8.970173312205961,4.719829054537816e-10,0.23690584721132832,12261.438192550215,10.838277488015608,-0.448,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 60M-325,Heliene,Mono-c-Si,0,325.0,296.5,1.6517,,,60.0,10.13,40.67,9.41,34.61,0.0038038150000000008,-0.110821683,49.06,1.5779837160747556,10.14018937146562,6.279584010393653e-11,0.11984382712552832,119.14552154120065,15.64308595854215,-0.37555,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M325,Heliene,Mono-c-Si,0,325.0,288.8,1.838103,1.893,0.971,72.0,9.27,46.02,8.69,37.72,0.0057474,-0.15646800000000002,49.0,1.9679835451372407,9.277075502660084,6.396832307026722e-10,0.28760037343356665,376.80093752171496,12.016528414165514,-0.461,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72P-325,Heliene,Multi-c-Si,0,325.0,290.3,1.94,,,72.0,9.05,46.11,8.745,37.42,0.0035114000000000005,-0.14132715,50.8,1.8073271583047945,9.050219839195838,7.523162557743618e-11,0.29101768241193754,11980.179118492713,5.066262103869696,-0.405,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M330,Heliene,Mono-c-Si,0,330.0,293.5,1.838103,1.893,0.971,72.0,9.34,46.31,8.76,37.96,0.0057908,-0.157454,49.0,1.9799154733406414,9.34678816620644,6.413280028778962e-10,0.2870183860008407,394.91555860207774,11.969732851152699,-0.461,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M335,Heliene,Mono-c-Si,0,335.0,298.1,1.838103,1.893,0.971,72.0,9.41,46.64,8.83,38.21,0.0058342,-0.15857600000000002,49.0,1.9928685303113787,9.416535821711255,6.378438521946956e-10,0.28973783220013727,417.1524074899814,11.850583705199185,-0.461,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M340,Heliene,Mono-c-Si,0,340.0,307.8,1.902197,1.943,0.979,72.0,9.49,46.95,8.89,38.503,0.005599099999999999,-0.1450755,47.1,1.9289930165456675,9.499559606702798,2.5127585501442807e-10,0.30256793155058215,300.36485812576825,14.20176235382563,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M345,Heliene,Mono-c-Si,0,345.0,312.4,1.902197,1.943,0.979,72.0,9.57,47.260000000000005,8.950000000000001,38.842999999999996,0.0056463,-0.14603340000000004,47.1,1.9458449635707267,9.58056284456808,2.6618499805070773e-10,0.29055525257873627,263.2448079396138,14.664395542214509,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M350,Heliene,Mono-c-Si,0,350.0,317.1,1.902197,1.943,0.979,72.0,9.65,47.540000000000006,9.010000000000002,39.132999999999996,0.0056935,-0.14689860000000002,47.1,1.960764048689226,9.661558781711072,2.7932885343971943e-10,0.28181255321412757,235.27490669844343,15.041444596241892,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M355,Heliene,Mono-c-Si,0,355.0,321.8,1.902197,1.943,0.979,72.0,9.68,47.82000000000001,9.070000000000002,39.422999999999995,0.0057112,-0.14776380000000003,47.1,1.970288642118009,9.689012986471786,2.7441317570312484e-10,0.27546290302541976,295.848789151255,14.834395844571539,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 66M-360 HJT,Heliene,Mono-c-Si,0,360.0,338.2,1.74,,,66.0,9.41,48.62,8.9,40.45,0.00256893,-0.12208481999999998,45.3,1.6905433346181447,9.418541069979145,3.0008446565224454e-12,0.318442144936125,350.8390160372041,-1.240166230235149,-0.3129,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M360,Heliene,Mono-c-Si,0,360.0,326.5,1.902197,1.943,0.979,72.0,9.709999999999999,48.10000000000001,9.130000000000003,39.712999999999994,0.0057288999999999994,-0.14862900000000004,47.1,1.9798194921760597,9.716595298789747,2.696549422629869e-10,0.2691965190121942,396.3275316758627,14.630224122274804,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 120HC-365,Heliene,Mono-c-Si,0,365.0,342.3,1.83,,,60.0,11.67,41.04,10.43,34.99,0.00699033,-0.11117735999999999,44.0,1.5975681879654609,11.695008157785233,7.509476420094708e-11,0.09508696411382941,44.37211588816843,16.563437107993494,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M365,Heliene,Mono-c-Si,0,365.0,331.2,1.902197,1.943,0.979,72.0,9.739999999999998,48.38000000000001,9.190000000000003,39.952999999999996,0.005746599999999999,-0.14949420000000002,47.1,1.9879785970047932,9.744337571230988,2.6065231346435527e-10,0.2693754813457335,604.8817363161936,14.273964971818117,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 120HC-370,Heliene,Mono-c-Si,0,370.0,347.1,1.83,,,60.0,11.75,41.22,10.54,35.12,0.00703825,-0.11166498,44.0,1.6006800783552637,11.774749077205092,7.134505642742031e-11,0.09839365286615259,46.713880082477324,16.00227589822233,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M370,Heliene,Mono-c-Si,0,370.0,335.9,1.902197,1.943,0.979,72.0,9.769999999999998,48.66000000000001,9.280000000000003,40.153,0.005764299999999998,-0.15035940000000003,47.1,1.9920660058315407,9.770003696714419,2.406707128089606e-10,0.2750105188434015,726955.5797208428,13.485609934716438,-0.428,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-370 Bifacial,Heliene,Mono-c-Si,1,370.0,339.2,1.86,,,72.0,9.85,47.19,9.2,40.15,0.0032308000000000003,-0.12760175999999998,48.41,1.7995030183383436,9.858716615788975,3.914198261246684e-11,0.15194040687703853,171.69656810489462,12.48265853428287,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 120HC-375,Heliene,Mono-c-Si,0,375.0,351.9,1.83,,,60.0,11.83,41.4,10.65,35.26,0.00708617,-0.11215259999999998,44.0,1.6041074840534821,11.854121696023082,6.813364902983396e-11,0.10051630487668076,49.296197466771275,15.492735433436685,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-375,Heliene,Mono-c-Si,0,375.0,347.8,1.92,,,72.0,9.9,48.96,9.22,40.67,0.0031680000000000002,-0.12915648,45.89,1.8200953134401272,9.917473671923812,1.9978501033061684e-11,0.28570797607112347,161.872615412572,9.195420822106023,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-375 Bifacial,Heliene,Mono-c-Si,1,375.0,343.9,1.86,,,72.0,9.92,47.19,9.09,41.34,0.00325376,-0.12760175999999998,48.41,1.8443505738594044,9.920103869043988,7.283886965772946e-11,0.0009999900026991702,95.50391977478017,18.278308439034216,-0.3675,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 120HC-380,Heliene,Mono-c-Si,0,380.0,356.7,1.83,,,60.0,11.92,41.6,10.75,35.4,0.00714008,-0.1126944,44.0,1.6095281892406468,11.944482053353942,6.628106032841881e-11,0.103939840835356,50.60698499157785,15.157198714741154,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-380,Heliene,Mono-c-Si,0,380.0,352.6,1.92,,,72.0,9.98,49.55,9.23,41.2,0.0031936,-0.1307129,45.89,1.8494094714719451,10.00205640447644,2.2236432790389342e-11,0.2809904559291843,127.14152222728983,10.104164883062445,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-380 Bifacial,Heliene,Mono-c-Si,1,380.0,348.6,1.86,,,72.0,9.63,50.51,9.23,41.2,0.0031586400000000008,-0.13657903999999998,48.41,1.8714764067108351,9.630003501905776,1.8292899803984964e-11,0.3636321822534716,999992.1977751398,5.876615307446201,-0.3675,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 72M-385,Heliene,Mono-c-Si,0,385.0,355.6,1.97,,,72.0,10.18,48.62,9.67,39.81,0.00399056,-0.12918333999999998,46.51,1.8066909131516444,10.18289544900233,2.0835298830810048e-11,0.3398546994818398,1194.882359931037,8.340266089700902,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-385 Bifacial,Heliene,Mono-c-Si,1,385.0,353.4,1.86,,,72.0,10.06,47.9,9.24,41.76,0.0032996800000000006,-0.1295216,48.41,1.867125298070956,10.062128686560879,6.911948106541879e-11,0.02083592426475867,98.4688881701693,17.64078426150386,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-390 M10 SL,Heliene,Mono-c-Si,0,390.0,367.0,1.88,,,54.0,13.26,37.22,12.54,31.27,0.00578136,-0.09375718,43.3,1.3131198370027757,13.260275982148693,6.492681381250316e-12,0.14284609965277062,6863.267911844629,1.6792077087786135,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-390,Heliene,Mono-c-Si,0,390.0,360.4,1.97,,,72.0,10.24,48.94,9.72,40.11,0.00401408,-0.13003358,46.51,1.8200667488692595,10.243596632850066,2.1403126872970116e-11,0.3355711931734073,955.4072456341516,8.528179103577397,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-390 G1 Bifacial,Heliene,Mono-c-Si,1,390.0,360.1,1.92,,,72.0,10.24,48.94,9.72,40.11,0.0031744,-0.12925054,47.18,1.7947992421650087,10.244200970209624,1.464793216257541e-11,0.3412378603081961,831.7782762284605,5.999264769727366,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M390,Heliene,Mono-c-Si,0,390.0,347.9,2.574,1.98,1.3,96.0,8.62,59.3,8.14,47.91,0.0075856,-0.215852,46.9,2.5898484005626776,8.620085115193001,9.80322275144731e-10,0.4797811754245583,48591.791769501906,8.572520759406066,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-395 M10 SL,Heliene,Mono-c-Si,0,395.0,371.8,1.88,,,54.0,13.28,37.38,12.56,31.49,0.00579008,-0.09416022000000002,43.3,1.372782308081365,13.288008608807756,1.9589299792726168e-11,0.1262545370261143,209.35724318195153,11.297858487931881,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-395 G1,Heliene,Mono-c-Si,0,395.0,365.4,1.92,,,72.0,10.29,49.26,9.78,40.4,0.0035294699999999994,-0.12827304,47.2,1.7967763540483326,10.293278729695754,1.2708354336736203e-11,0.34062663437778445,1069.026258998371,6.191383066910173,-0.3527,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-395 G1 Bifacial,Heliene,Mono-c-Si,1,395.0,364.9,1.92,,,72.0,10.29,49.26,9.78,40.4,0.0031899,-0.13009566,47.18,1.8060773029241386,10.29306061137419,1.4639121648284743e-11,0.33854552337630833,1138.214922592043,5.946765047888856,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M395,Heliene,Mono-c-Si,0,395.0,352.5,2.574,1.98,1.3,96.0,8.67,59.5,8.2,48.17,0.007629599999999999,-0.21658,46.9,2.601091156331331,8.680795654068053,1.0094007840364935e-09,0.463862382842014,999999.9208578012,8.770342989310175,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 108HC-400 M10 SL,Heliene,Mono-c-Si,0,400.0,376.7,1.88,,,54.0,13.3,37.56,12.58,31.81,0.005798800000000001,-0.09461364000000001,43.3,1.382964510672693,13.307217565245157,2.1040096522225034e-11,0.11136572173367569,205.2165872044676,11.93306349980718,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-400 G1,Heliene,Mono-c-Si,0,400.0,370.2,1.92,,,72.0,10.35,49.58,9.83,40.7,0.0035500499999999995,-0.12910632000000002,47.2,1.8098743296667321,10.353976512186646,1.304939151533225e-11,0.3364561438233258,875.7224373330733,6.373148833556555,-0.3527,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-400 G1 Bifacial,Heliene,Mono-c-Si,1,400.0,369.6,1.92,,,72.0,10.35,49.58,9.83,40.7,0.0032085,-0.13094078,47.18,1.819251412123817,10.353755738847948,1.5032166289194962e-11,0.3343668850153023,921.4422158888482,6.1279222065395675,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M400,Heliene,Mono-c-Si,0,400.0,357.1,2.574,1.98,1.3,96.0,8.82,59.8,8.26,48.43,0.0077616,-0.21767199999999998,46.9,2.627308557500166,8.826536740081206,1.137683055722891e-09,0.4548911823070345,613.7834290989126,9.721802290434841,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-405 M10 SL,Heliene,Mono-c-Si,0,405.0,381.5,1.88,,,54.0,13.32,37.74,12.6,32.15,0.005807520000000001,-0.09506706000000001,43.3,1.3935659360520072,13.326281538419826,2.2758890667907606e-11,0.09472109296320144,200.85604526551387,12.636432967777468,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-405 G1,Heliene,Mono-c-Si,0,405.0,375.0,1.92,,,72.0,10.41,49.9,9.88,41.0,0.0035706299999999996,-0.12993960000000002,47.2,1.8229768418774792,10.414653814664177,1.3396024699655049e-11,0.33232627045158997,743.3722185981146,6.553151344606089,-0.3527,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-405 G1 Bifacial,Heliene,Mono-c-Si,1,405.0,374.4,1.92,,,72.0,10.41,49.9,9.88,41.0,0.0032271,-0.1317859,47.18,1.832430196616083,10.41443035063643,1.5431682276722143e-11,0.33022891492231704,775.9392776765953,6.307327293653283,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M405,Heliene,Mono-c-Si,0,405.0,361.7,2.574,1.98,1.3,96.0,8.86,60.0,8.32,48.68,0.0077967999999999996,-0.21839999999999998,46.9,2.635027459325319,8.864518124792186,1.13578711553913e-09,0.44224593048857747,867.2408347983301,9.658394148472503,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-410 M10 SL,Heliene,Mono-c-Si,0,410.0,386.3,1.88,,,54.0,13.34,38.03,12.62,32.49,0.005816239999999999,-0.09579757000000001,43.3,1.406209505688639,13.345781398417806,2.3654981255297347e-11,0.0869001740727979,200.51348214018557,12.976625533233658,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 72M-410 G1,Heliene,Mono-c-Si,0,410.0,379.7,1.92,,,72.0,10.47,50.2,9.93,41.32,0.00359121,-0.1307208,47.2,1.8361591520625993,10.475304583681973,1.3913214561880095e-11,0.32388660745253606,639.2759617747656,6.835010322529089,-0.3527,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M410,Heliene,Mono-c-Si,0,410.0,366.3,2.574,1.98,1.3,96.0,8.9,60.25,8.37,48.98,0.007832,-0.21931,46.9,2.646993335006313,8.903468018054278,1.1524161544017054e-09,0.42856999699515724,1099.843396467766,9.744225028665797,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-415 M10 NTYP SL,Heliene,Mono-c-Si,0,415.0,391.7,1.95,,,54.0,13.91,38.02,13.13,31.65,0.0044651099999999996,-0.09075374000000001,45.09,1.3007563109542029,13.925659342350944,2.7660980320893278e-12,0.1707199817781158,151.64844700960197,-0.11028562923924316,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-415 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,415.0,391.7,1.95,,,54.0,13.6,38.97,12.87,32.31,0.0043656,-0.09302139,45.09,1.329250871182566,13.613195958894476,2.48460495533463e-12,0.19057628895457934,196.41145850921555,-0.8220025196197019,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M415,Heliene,Mono-c-Si,0,415.0,370.9,2.574,1.98,1.3,96.0,8.95,60.4,8.43,49.23,0.007876,-0.219856,46.9,2.6554693198450816,8.952450294552115,1.1795862787507555e-09,0.4094983404648782,1495.7448190857872,9.89895999310233,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96P415,Heliene,Multi-c-Si,0,415.0,371.6,2.520071,1.943,1.2970000000000002,96.0,8.855,61.44,8.389000000000001,49.800000000000004,0.0048702500000000004,-0.20152319999999999,47.7,2.5465953906023158,8.855004947910757,2.9461411573966786e-10,0.49497697010456027,886074.8962623511,9.534111296473002,-0.449,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-420 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,420.0,396.6,1.95,,,54.0,13.64,39.17,12.91,32.59,0.00437844,-0.09349879000000001,45.09,1.3381581690684685,13.652608560183022,2.6080663683100025e-12,0.18094306465055116,195.74506278941143,-0.4466600748003042,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M420,Heliene,Mono-c-Si,0,420.0,375.5,2.574,1.98,1.3,96.0,9.0,60.55,8.48,49.53,0.00792,-0.22040200000000001,46.9,2.667274664666076,9.002311235281507,1.240057813635819e-09,0.383426754702634,1493.0741668429775,10.298697313292564,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96P420,Heliene,Multi-c-Si,0,420.0,376.2,2.520071,1.943,1.2970000000000002,96.0,8.925,61.515,8.464,49.96,0.004908750000000001,-0.2017692,47.7,2.551917263411067,8.934441597344595,3.035427789344099e-10,0.4775387032576599,999999.5532520624,9.719942121990034,-0.449,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 108HC-425 M10 NTYP SL,Heliene,Mono-c-Si,0,425.0,401.4,1.95,,,54.0,14.05,38.29,13.23,32.18,0.00451005,-0.09139823,45.09,1.3173013948757444,14.066074987772517,3.273676772894344e-12,0.14395278898468836,125.8188632344241,1.2211852318690892,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-425 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,425.0,401.4,1.95,,,54.0,13.67,39.36,12.95,32.88,0.00438807,-0.09395232,45.09,1.3466306377171195,13.681206624943943,2.7306996143462884e-12,0.16986811276835895,207.20753268340314,-0.08829760831245359,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96P425,Heliene,Multi-c-Si,0,425.0,380.8,2.520071,1.943,1.2970000000000002,96.0,8.995000000000001,61.585,8.529,50.14,0.004947250000000001,-0.2019988,47.7,2.5589608847040246,8.995004866709642,3.177526164915868e-10,0.45758832368822794,845968.0576455563,10.065178028272584,-0.449,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-430 M10 NTYP SL,Heliene,Mono-c-Si,0,430.0,406.2,1.95,,,54.0,14.13,38.42,13.28,32.45,0.00453573,-0.09170854,45.09,1.3260282015041964,14.146371816507095,3.604525449736194e-12,0.12977714469366625,112.00657273956,1.9913262567171603,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-430 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,430.0,406.2,1.95,,,54.0,13.71,39.55,12.99,33.17,0.004400909999999999,-0.09440584999999999,45.09,1.355532449288067,13.720569045949373,2.8837495761567e-12,0.15872405800412817,205.8943492355727,0.33969036095119187,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96P430,Heliene,Multi-c-Si,0,430.0,385.5,2.520071,1.943,1.2970000000000002,96.0,9.065000000000001,61.655,8.594,50.32,0.004985750000000001,-0.20222840000000003,47.7,2.5646304627513294,9.065004812364357,3.286304009989916e-10,0.437943768488931,825158.6575797839,10.295629403747677,-0.449,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-435 M10 NTYP SL,Heliene,Mono-c-Si,0,435.0,411.1,1.95,,,54.0,14.22,38.5,13.32,32.72,0.00456462,-0.0918995,45.09,1.3347752985680992,14.23679650663625,4.112534702605213e-12,0.11173098608397199,94.59196828313137,3.069346180668711,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-435 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,435.0,411.1,1.95,,,54.0,13.75,39.69,13.05,33.42,0.00441375,-0.09474002999999999,45.09,1.3618133868502256,13.758609111622025,2.9903538243417196e-12,0.14737161952352612,235.37385273699292,0.6103787711702041,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96P435,Heliene,Multi-c-Si,0,435.0,390.1,2.520071,1.943,1.2970000000000002,96.0,9.135000000000002,61.725,8.658999999999999,50.525,0.005024250000000001,-0.20245800000000003,47.7,2.5713278629825664,9.135124683094187,3.430303643022931e-10,0.41514276614724044,30415.966154152164,10.610122586343477,-0.449,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-440 M10 NTYP SL,Heliene,Mono-c-Si,0,440.0,415.9,1.95,,,54.0,14.3,38.63,13.36,32.98,0.0045903,-0.09220981,45.09,1.3438416407764355,14.316660778472105,4.545205716257309e-12,0.09853204860972839,84.57037576613857,3.88716078649294,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-440 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,440.0,415.9,1.95,,,54.0,13.79,39.87,13.09,33.65,0.004426589999999999,-0.09516969,45.09,1.3693782033054702,13.79823288874552,3.088952316448946e-12,0.14082626372991489,235.8824832142553,0.8562391830985643,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-440 Bifacial,Heliene,Mono-c-Si,1,440.0,410.7,2.21,,,72.0,11.17,50.43,10.51,41.93,0.003378925,-0.132151815,45.42,1.8206128601966145,11.182773825849146,1.0241463782409421e-11,0.2672268544583276,233.67501713944858,3.1085105891781035,-0.3377,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M440,Heliene,Mono-c-Si,0,440.0,397.1,2.520071,1.943,1.2970000000000002,96.0,9.331,60.992,8.736,50.657000000000004,0.005132049999999999,-0.1890752,47.3,2.529406193388273,9.33915437521479,3.0909732310098235e-10,0.31285018569509443,357.9925188676035,15.962750058595795,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96P440,Heliene,Multi-c-Si,0,440.0,394.7,2.520071,1.943,1.2970000000000002,96.0,9.205000000000002,61.795,8.723999999999998,50.73,0.005062750000000001,-0.2026876,47.7,2.578689772643492,9.205409965133475,3.6008151148560383e-10,0.3925461672164929,8813.913395662586,10.9775016537962,-0.449,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 108HC-445 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,445.0,420.8,1.95,,,54.0,13.86,40.05,13.16,33.81,0.0044490599999999995,-0.09559934999999999,45.09,1.375546152901566,13.868027857450954,3.104600926284034e-12,0.140068495482903,241.82658471626286,0.8549626606273341,-0.2959,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M445,Heliene,Mono-c-Si,0,445.0,401.8,2.520071,1.943,1.2970000000000002,96.0,9.399,61.193999999999996,8.801,50.855000000000004,0.00516945,-0.18970139999999996,47.3,2.5384227326311266,9.407049515549884,3.1328371342305025e-10,0.30763632058841234,359.2109361444744,16.020367569960214,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-450,Heliene,Mono-c-Si,0,450.0,415.7,2.21,,,72.0,11.51,50.74,10.69,42.17,0.0037292399999999996,-0.13446100000000002,48.05,1.8638210913364568,11.53324199025602,1.6734765309515625e-11,0.25739927477880364,127.47036662594068,5.865129770661316,-0.3447,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-450 Bifacial,Heliene,Mono-c-Si,1,450.0,420.2,2.21,,,72.0,11.51,50.74,10.69,42.17,0.003481775,-0.13296417000000002,45.42,1.8429766341063607,11.534005872954552,1.229376408019886e-11,0.2617619692057174,125.50596587886729,4.452386834545715,-0.3377,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M450,Heliene,Mono-c-Si,0,450.0,406.4,2.520071,1.943,1.2970000000000002,96.0,9.472,61.392999999999994,8.863,51.056000000000004,0.0052096,-0.1903183,47.3,2.548657377624475,9.480396238404047,3.2138678453857975e-10,0.3013463844238713,339.95618488221777,16.190473653901613,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M455,Heliene,Mono-c-Si,0,455.0,411.1,2.520071,1.943,1.2970000000000002,96.0,9.545,61.59199999999999,8.924999999999999,51.257000000000005,0.00524975,-0.19093519999999997,47.3,2.558888299837926,9.553727657845453,3.296231879891421e-10,0.2951454569783453,322.785751948642,16.35917719167863,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-460,Heliene,Mono-c-Si,0,460.0,425.2,2.21,,,72.0,11.93,51.26,10.88,42.31,0.0038653199999999998,-0.135839,48.05,1.8935638955856735,11.973716526432163,1.9794537759803655e-11,0.2798854302036542,76.37919725530624,7.078758487858911,-0.3447,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-460 Bifacial,Heliene,Mono-c-Si,1,460.0,429.8,2.21,,,72.0,11.93,51.26,10.88,42.31,0.003608825,-0.13432682999999998,45.42,1.87228807748129,11.974825837212617,1.4545990547797732e-11,0.2842572560348327,75.65255399535073,5.656054642003551,-0.3377,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M460,Heliene,Mono-c-Si,0,460.0,415.8,2.520071,1.943,1.2970000000000002,96.0,9.618,61.79099999999999,8.986999999999998,51.458000000000006,0.0052899,-0.19155209999999998,47.3,2.569115561106909,9.62704391620302,3.379936658490203e-10,0.28903167059266366,307.37865632080417,16.526496756147065,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M465,Heliene,Mono-c-Si,0,465.0,420.4,2.520071,1.943,1.2970000000000002,96.0,9.691,61.98999999999999,9.048999999999998,51.659000000000006,0.00533005,-0.19216899999999998,47.3,2.579339221838381,9.700345154752487,3.4649894865906373e-10,0.283003209352299,293.4765982531219,16.692450565741453,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-470 M10 SL,Heliene,Mono-c-Si,0,470.0,442.8,2.29,,,66.0,13.21,45.25,12.48,37.7,0.005482150000000002,-0.11307975,43.5,1.6296864305814285,13.221046992314301,1.138241154227789e-11,0.19634934906546916,234.79466973815138,7.4267757128614225,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-470,Heliene,Mono-c-Si,0,470.0,434.7,2.21,,,72.0,12.27,51.54,11.07,42.45,0.00397548,-0.136581,48.05,1.9124614378669063,12.326977690909041,2.2690491275805116e-11,0.2821210316878896,60.75404269770635,8.066348808968792,-0.3447,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M470,Heliene,Mono-c-Si,0,470.0,425.1,2.520071,1.943,1.2970000000000002,96.0,9.764,62.188999999999986,9.110999999999997,51.86000000000001,0.0053701999999999995,-0.19278589999999995,47.3,2.589559341052854,9.77363151369502,3.551397554644533e-10,0.27705830731163106,280.8694024106614,16.857056493571736,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-475 M10 SL,Heliene,Mono-c-Si,0,475.0,447.6,2.29,,,66.0,13.24,45.4,12.51,37.9,0.005494600000000001,-0.1134546,43.5,1.6365764109946803,13.25068722353903,1.1699508721340108e-11,0.18969928945133402,235.01132858258813,7.647851139393128,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 96M475,Heliene,Mono-c-Si,0,475.0,429.8,2.520071,1.943,1.2970000000000002,96.0,9.837000000000002,62.387999999999984,9.172999999999996,52.06100000000001,0.00541035,-0.19340279999999996,47.3,2.5997759764257182,9.84690313213825,3.6391679385749334e-10,0.27119524678874724,269.3842493262317,17.02033207626534,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-480 M10 SL,Heliene,Mono-c-Si,0,480.0,452.4,2.29,,,66.0,13.26,45.57,12.54,38.22,0.0055029,-0.11387943,43.5,1.645783330756223,13.269323287138368,1.234874208352475e-11,0.1739415090930328,247.38747013690627,8.106918087254295,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-485 M10 SL,Heliene,Mono-c-Si,0,485.0,457.2,2.29,,,66.0,13.28,45.77,12.56,38.49,0.0055112,-0.11437923000000001,43.5,1.6550944499410722,13.288908938023036,1.2805181562621157e-11,0.16514386796638916,246.16969718301957,8.414220657729683,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-490 M10 SL,Heliene,Mono-c-Si,0,490.0,462.1,2.29,,,66.0,13.3,46.0,12.58,38.88,0.005519500000000001,-0.11495400000000001,43.5,2.3372528031381363,13.300094543074984,3.7957053425330244e-13,3.0655528307330298,508091.9683319101,99.99689137811494,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-495 M10 SL,Heliene,Mono-c-Si,0,495.0,466.9,2.29,,,66.0,13.32,46.21,12.6,39.28,0.005527800000000001,-0.11547879000000001,43.5,1.6796932999261527,13.327196708232824,1.480745429147617e-11,0.12818589287893928,237.2523721324625,9.67987583632592,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 132HC-500 M10 SL,Heliene,Mono-c-Si,0,500.0,471.7,2.29,,,66.0,13.34,46.41,12.62,39.62,0.0055360999999999995,-0.11597858999999999,43.5,1.6904531573375878,13.346439552294731,1.5692037432061203e-11,0.1131936641908547,234.4888925401945,10.186269817024083,-0.3279,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-520 M10 Bifacial,Heliene,Mono-c-Si,1,520.0,489.6,2.51,,,72.0,13.28,48.73,12.52,41.56,0.005829920000000001,-0.12333562999999999,43.8,1.7800858119414238,13.288295947693513,1.6841679248852705e-11,0.12195319310839942,195.2204217996551,9.434178692787732,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-520 M10 SL,Heliene,Mono-c-Si,0,520.0,485.9,2.49,,,72.0,13.62,48.72,12.64,41.17,0.0044946,-0.1252104,44.91,1.809431376481628,13.640249956070813,2.661585781915335e-11,0.14638011392256242,98.45439419326438,11.822181742873058,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-520 M10 SL Bifacial,Heliene,Mono-c-Si,1,520.0,489.3,2.58,,,72.0,13.42,49.22,12.52,41.56,0.005891380000000001,-0.12457582,43.8,1.798268458242765,13.437750440714343,1.689844113024587e-11,0.15824764845180178,119.64116727874838,9.414918072086452,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-525 M10 SL,Heliene,Mono-c-Si,0,525.0,490.7,2.49,,,72.0,13.64,48.97,12.7,41.36,0.004501200000000001,-0.12585290000000002,44.91,1.8152337773218157,13.658394384699028,2.5412016786879543e-11,0.14934045069759277,110.740521508927,11.375832513619647,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-525 M10 SL Bifacial,Heliene,Mono-c-Si,1,525.0,494.1,2.58,,,72.0,13.44,49.47,12.58,41.75,0.00590016,-0.12520857,43.8,1.8040293494482909,13.455709224591626,1.6142470760977115e-11,0.1611842692822894,137.90092386077575,8.980310179724038,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-530 M10 Bifacial,Heliene,Mono-c-Si,1,530.0,499.2,2.51,,,72.0,13.37,49.72,12.64,41.94,0.005869429999999999,-0.12584131999999998,43.8,1.803984220990289,13.378746158085049,1.4135927963833727e-11,0.16601452653223153,253.78162702259488,7.810299433117062,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-530 M10 SL,Heliene,Mono-c-Si,0,530.0,495.5,2.49,,,72.0,13.66,49.22,12.76,41.56,0.0045078,-0.1264954,44.91,1.8212815298651759,13.676371349338186,2.4357858808453258e-11,0.15136578088758726,126.29726056790186,10.966413943033578,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-530 M10 SL Bifacial,Heliene,Mono-c-Si,1,530.0,498.9,2.58,,,72.0,13.46,49.72,12.64,41.94,0.005908940000000001,-0.12584131999999998,43.8,1.8098116011688965,13.473594047051499,1.5429862705437058e-11,0.16408519497941546,162.4671981745043,8.552760622776487,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-535 M10 SL,Heliene,Mono-c-Si,0,535.0,500.3,2.49,,,72.0,13.68,49.47,12.82,41.75,0.0045144,-0.1271379,44.91,1.827128034882603,13.694375358038409,2.3285060909630453e-11,0.1542597406238225,146.79796191262307,10.534383026854286,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-535 M10 SL Bifacial,Heliene,Mono-c-Si,1,535.0,503.7,2.58,,,72.0,13.48,49.97,12.7,42.13,0.0059177200000000004,-0.12647407,43.8,1.8156147420390392,13.491407165237057,1.4757675226348667e-11,0.1669511130277751,197.2883672901824,8.132105228742962,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-540 M10 Bifacial,Heliene,Mono-c-Si,1,540.0,508.9,2.51,,,72.0,13.5,50.22,12.77,42.32,0.0059265,-0.12710681999999998,43.8,1.8207590255534738,13.508571244435851,1.3991493021261253e-11,0.16987214390181654,267.55429777649385,7.632481685264365,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-540 M10 SL,Heliene,Mono-c-Si,0,540.0,505.1,2.49,,,72.0,13.5,50.22,12.77,42.32,0.004455000000000001,-0.1290654,44.91,1.845001576577223,13.507977091402111,2.0114843535443248e-11,0.16560174637046277,280.2554812372583,9.305399679190739,-0.347,N,2025.7.3,6/23/2025,4.0,bootstrapping +Heliene 144HC-540 M10 SL Bifacial,Heliene,Mono-c-Si,1,540.0,508.5,2.58,,,72.0,13.5,50.22,12.77,42.32,0.0059265,-0.12710681999999998,43.8,1.8207590255534738,13.508571244435851,1.3991493021261253e-11,0.16987214390181654,267.55429777649385,7.632481685264365,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-545 M10 SL Bifacial,Heliene,Mono-c-Si,1,545.0,513.4,2.58,,,72.0,13.52,50.31,12.83,42.51,0.005935279999999999,-0.12733461,43.8,1.8236524719308773,13.525956964606197,1.3983121321063087e-11,0.1601225232322037,363.41604658076596,7.600575085078716,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-550 M10 SL Bifacial,Heliene,Mono-c-Si,1,550.0,518.2,2.58,,,72.0,13.54,50.37,12.89,42.7,0.00594406,-0.12748647000000002,43.8,1.8259892404657996,13.543589546295799,1.4086382873860772e-11,0.14812892531212485,558.7518587815913,7.638543249106499,-0.3266,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-555 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,555.0,520.2,2.58,,,72.0,13.56,52.26,12.79,43.48,0.0042307199999999994,-0.12448331999999998,47.51,1.785759245927924,13.576229473868056,2.599599430041502e-12,0.24325950579047217,203.24743291447035,-0.18519919290440573,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-560 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,560.0,525.1,2.58,,,72.0,13.6,52.4,12.83,43.72,0.0042432,-0.1248168,47.51,1.7927690639825338,13.615541927578718,2.703609676286039e-12,0.23225858045325887,203.2384130407645,0.11510849059333439,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-565 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,565.0,529.9,2.58,,,72.0,13.64,52.55,12.87,43.98,0.00425568,-0.12517409999999998,47.51,1.8003404876828561,13.65479857865264,2.8209061536836483e-12,0.22034624233016925,203.09536601417238,0.44322065490297785,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-565 M10 SL Bifacial,Heliene,Mono-c-Si,1,565.0,531.9,2.794,,,78.0,13.42,53.32,12.52,45.02,0.00560956,-0.13527284,43.2,1.9640808340196478,13.43725046329122,2.1132076776138016e-11,0.16870438949710206,131.24360067297835,11.180239468477053,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-570 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,570.0,534.7,2.58,,,72.0,13.67,52.69,12.91,44.24,0.00426504,-0.12550758,47.51,1.8071280287489442,13.683352276794391,2.9217604154953055e-12,0.20793528205832212,212.88319226399835,0.7138994418609811,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-570 M10 SL Bifacial,Heliene,Mono-c-Si,1,570.0,536.7,2.794,,,78.0,13.44,53.59,12.58,45.23,0.005617919999999999,-0.13595783,43.2,1.9704257255831856,13.4552070149848,2.0218195386856253e-11,0.1714506361906892,151.52852545313903,10.753571097583405,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-575 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,575.0,539.5,2.58,,,72.0,13.71,52.83,12.95,44.48,0.00427752,-0.12584106,47.51,1.81412368417979,13.722694465489953,3.0353547293641733e-12,0.19716093612974686,212.93345820404494,1.0075372636171875,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-575 M10 SL Bifacial,Heliene,Mono-c-Si,1,575.0,541.5,2.794,,,78.0,13.46,53.86,12.64,45.44,0.005626280000000001,-0.13664281999999997,43.2,1.9767932009426614,13.473102081444278,1.9355414122967178e-11,0.17416263728008421,178.92035817415555,10.333788604460274,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-580 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,580.0,544.3,2.58,,,72.0,13.75,52.97,12.99,44.74,0.00429,-0.12617453999999997,47.51,1.8214965648409018,13.761943595931468,3.1714181383967732e-12,0.18471110111435343,212.64765276224983,1.3498553072420503,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-580 M10 SL Bifacial,Heliene,Mono-c-Si,1,580.0,546.3,2.794,,,78.0,13.48,54.13,12.7,45.64,0.00563464,-0.13732781,43.2,1.9829666407996722,13.490983714147365,1.8485637708433353e-11,0.17774241566481935,218.1382126690739,9.894280134947707,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-585 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,585.0,549.1,2.58,,,72.0,13.79,53.12,13.03,44.93,0.00430248,-0.12653184,47.51,1.8277176572123652,13.801554439833327,3.2351419124530876e-12,0.1792033306184183,213.87570207893054,1.491763705536895,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-585 M10 SL Bifacial,Heliene,Mono-c-Si,1,585.0,551.1,2.794,,,78.0,13.5,54.41,12.77,45.85,0.005643,-0.13803817,43.2,1.9888170763781858,13.508205709396865,1.7509599848509436e-11,0.18127358652998818,298.23057486988387,9.379317426747509,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-590 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,590.0,554.0,2.58,,,72.0,13.83,53.25,13.12,44.96,0.00431496,-0.1268415,47.51,1.827369706379829,13.838757488047811,3.0195037943235696e-12,0.1864091624745552,294.38107203039755,0.8717951264755512,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-590 M10 SL Bifacial,Heliene,Mono-c-Si,1,590.0,556.0,2.794,,,78.0,13.52,54.5,12.83,46.06,0.005651359999999999,-0.1382665,43.2,1.9919216078332171,13.525619527674746,1.7552168282703484e-11,0.16975826435224894,408.42075747370126,9.373900864106776,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 144HC-595 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,595.0,558.8,2.58,,,72.0,13.86,53.4,13.16,45.2,0.0043243199999999996,-0.1271988,47.51,1.8339294028736701,13.86776922232485,3.097211546968282e-12,0.17684512256662982,315.4850383449793,1.0623261602196234,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-595 M10 SL Bifacial,Heliene,Mono-c-Si,1,595.0,560.8,2.794,,,78.0,13.54,54.59,12.89,46.26,0.005659719999999999,-0.13849483,43.2,1.9948129092652889,13.543337187939862,1.7543485884159828e-11,0.15924176196549553,646.0929482390374,9.342407249628053,-0.3354,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-605 M10 NTYP SL,Heliene,Mono-c-Si,0,605.0,574.5,2.77,,,78.0,14.09,55.2,13.27,45.64,0.0062614551,-0.13318656,43.2,1.9150478446093158,14.10865844486915,4.194622628024309e-12,0.2661142095937772,200.95722065866673,1.983814826061349,-0.29697,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-605 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,605.0,574.2,2.79,,,78.0,13.57,56.64,12.8,47.1,0.005047497200000001,-0.137023488,43.3,1.953828447934199,13.585699113813021,3.4288874562445364e-12,0.26223611003994557,226.6716491419394,0.44834517300998006,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-610 M10 NTYP SL,Heliene,Mono-c-Si,0,610.0,579.4,2.77,,,78.0,14.14,55.35,13.3,45.92,0.0062836746,-0.13354848,43.2,1.9244985067661688,14.159458438415838,4.4777910706458964e-12,0.25250131039368573,183.48689891784613,2.5117289249608943,-0.29697,N,2025.7.3,6/23/2025,4.0,bootstrapping +Heliene 156HC-610 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,610.0,579.1,2.79,,,78.0,13.6,56.77,12.84,47.52,0.005058656,-0.13733798400000002,43.3,1.9636156174948125,13.613608836714807,3.7180322399814915e-12,0.23465266645585262,234.5002982115156,1.1014090599189321,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-615 M10 NTYP SL,Heliene,Mono-c-Si,0,615.0,584.2,2.77,,,78.0,14.19,55.5,13.32,46.2,0.0063058941,-0.1339104,43.2,1.9346285966813845,14.210850314017016,4.8212711707611796e-12,0.2389150388645025,162.59728278743123,3.118400637162646,-0.29697,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-615 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,615.0,583.9,2.79,,,78.0,13.64,56.92,12.88,47.75,0.005073534400000001,-0.137700864,43.3,1.9706894941669857,13.653077674018437,3.833581095171631e-12,0.22537446086518761,235.065321645506,1.3323111599194573,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-620 M10 NTYP SL,Heliene,Mono-c-Si,0,620.0,589.1,2.77,,,78.0,14.24,55.65,13.35,46.48,0.0063281136,-0.13427232,43.2,1.9441136048979062,14.261209881892553,5.142662343525516e-12,0.225410094144177,151.3369928637754,3.644741191938612,-0.29697,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-620 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,620.0,588.8,2.79,,,78.0,13.67,57.08,12.92,48.0,0.0050846932000000004,-0.138087936,43.3,1.9776723140141483,13.681872251099007,3.9271538102092744e-12,0.21539466137193572,248.01067633008458,1.5122766139451027,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-625 M10 NTYP SL,Heliene,Mono-c-Si,0,625.0,593.9,2.77,,,78.0,14.28,55.8,13.38,46.75,0.0063458892000000005,-0.13463424,43.2,1.952773630808611,14.300787863455056,5.417143176909144e-12,0.2130203318147199,146.332034006767,4.068852144459781,-0.29697,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-625 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,625.0,593.6,2.79,,,78.0,13.71,57.23,12.96,48.22,0.0050995716,-0.138450816,43.3,1.9845432828881604,13.721411024083169,4.035806930142433e-12,0.20711698494474903,248.8447880026714,1.716242601446413,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-630 M10 NTYP SL,Heliene,Mono-c-Si,0,630.0,598.8,2.77,,,78.0,14.33,55.95,13.42,47.01,0.006368108700000001,-0.13499616,43.2,1.9611917597718997,14.35032643993278,5.688113084968615e-12,0.2014017811298174,141.98686714660522,4.460819032423544,-0.29697,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-630 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,630.0,598.5,2.79,,,78.0,13.75,57.38,13.01,48.4,0.00511445,-0.13881369600000001,43.3,1.9899335769617073,13.760490099243212,4.0627152598798254e-12,0.20246306466652336,265.38043881652584,1.743597967921557,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-635 M10 NTYP SL,Heliene,Mono-c-Si,0,635.0,603.7,2.77,,,78.0,14.38,56.11,13.47,47.19,0.006390328200000001,-0.135382208,43.2,1.967499016219972,14.399846407270243,5.767190020604597e-12,0.19744335952558711,143.06042771274642,4.548827658785532,-0.29697,N,2025.7.3,6/23/2025,2.0,first_pass +Heliene 156HC-635 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,635.0,603.4,2.79,,,78.0,13.79,57.54,13.07,48.59,0.0051293284,-0.139200768,43.3,1.9950026291065264,13.798997661341101,4.0539874005044795e-12,0.19782303391353054,303.18763271137215,1.6937964055542665,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-640 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,640.0,608.2,2.79,,,78.0,13.83,57.69,13.12,48.77,0.0051442068,-0.13956364799999998,43.3,2.0003926671473478,13.83815823145228,4.080851104365343e-12,0.19324510561624778,327.5930366186166,1.7209815475928316,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Heliene 156HC-645 M10 NTYP SL Bifacial,Heliene,Mono-c-Si,1,645.0,613.1,2.79,,,78.0,13.86,57.85,13.16,49.01,0.0051553656,-0.13995072,43.3,2.0071564227295484,13.86725087223016,4.1652553849471115e-12,0.18442490081830507,352.52712337363215,1.8711468862630491,-0.29734,N,2025.7.3,6/23/2025,4.0,first_pass +Helios USA 6TA,Helios USA,Mono-c-Si,0,255.0,229.6,1.6632,1.68,0.99,60.0,8.86,37.5,8.32,30.65,0.0094802,-0.14024999999999999,46.1,1.6546480298799044,8.864418852955453,1.262636053060262e-09,0.24414522066546795,489.5225848943043,7.410573439128044,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM175-M125-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,175.0,154.2,1.2292800000000002,1.56,0.788,72.0,5.23,44.7,4.9,35.8,0.0026150000000000006,-0.16539,46.9,1.9660088069170025,5.233513875997077,6.929883614082336e-10,0.6646139537159257,989.2023020486712,8.580128344903912,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM180-M125-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,180.0,158.7,1.2292800000000002,1.56,0.788,72.0,5.29,44.8,5.0,36.0,0.002645,-0.16576,46.9,1.9666841367638763,5.299363238347378,6.779955110670799e-10,0.629626032555327,999999.9802128788,8.249171105859912,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM185-M125-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,185.0,163.3,1.2292800000000002,1.56,0.788,72.0,5.43,45.0,5.09,36.4,0.0027150000000000004,-0.1665,46.9,1.9905180658905992,5.433377820427807,8.182458570657577e-10,0.5601972797459619,900.5433989041985,9.722442916125093,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM190-M125-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,190.0,167.9,1.2292800000000002,1.56,0.788,72.0,5.56,45.2,5.19,36.6,0.00278,-0.16724,46.9,2.0053271357958464,5.56541599603944,8.914643304376786e-10,0.5398061007260472,554.1591212448036,10.292628832266002,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM195-M125-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,195.0,172.4,1.2292800000000002,1.56,0.788,72.0,6.05,45.8,5.3,36.8,0.003025,-0.16945999999999997,46.9,2.101123589126138,6.090644100606615,1.8873173188725058e-09,0.5464571208921642,81.34184590166065,16.655868824577034,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM210-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,210.0,185.4,1.5843599999999998,1.63,0.972,60.0,7.88,36.4,7.24,29.0,0.0047279999999999996,-0.13104,47.1,1.593566736423025,7.902472581286187,9.177651765152689e-10,0.38832377175847677,136.1655806297785,10.406840667002088,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM215-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,215.0,190.0,1.5843599999999998,1.63,0.972,60.0,7.99,36.5,7.39,29.1,0.004794,-0.1314,47.1,1.5927132637376433,8.006987503440593,8.701852023663259e-10,0.38108259196425986,179.24063287318933,9.785308919209875,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM220-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,220.0,194.5,1.5843599999999998,1.63,0.972,60.0,8.1,36.6,7.53,29.2,0.00486,-0.13176000000000002,47.1,1.593274243100114,8.112747047270961,8.40272464676003e-10,0.3739480214767431,237.62209759815636,9.335860607135114,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM225-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,225.0,204.9,1.6367999999999998,1.65,0.992,60.0,8.25,36.7,7.65,29.4,0.00660825,-0.15017640000000002,44.3,1.5552663254332384,8.266568447933603,4.5535047747396676e-10,0.3621377698729146,180.32087808874974,-8.908131561691798,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM230-M156-60,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,230.0,203.1,1.5843599999999998,1.63,0.972,60.0,8.35,36.8,7.78,29.6,0.004175000000000001,-0.1288,47.1,1.6079991661833328,8.360585725708486,9.455841380004513e-10,0.327929397172246,258.6701790088311,13.395618689237764,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM230-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,230.0,209.6,1.6367999999999998,1.65,0.992,60.0,8.35,36.8,7.78,29.6,0.006688350000000001,-0.15058560000000001,44.3,1.559232575270168,8.362244936283748,4.614015474288581e-10,0.34066886953322184,232.307098372565,-8.910202977199113,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM235-M156-60,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,235.0,207.6,1.5843599999999998,1.63,0.972,60.0,8.47,36.9,7.88,29.8,0.004235000000000001,-0.12915,47.1,1.6175885287081868,8.481532046352942,1.0303226625433559e-09,0.30595430326439077,224.71587322132845,14.063139340812732,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM235-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,235.0,214.2,1.6367999999999998,1.65,0.992,60.0,8.47,36.9,7.89,29.8,0.006784470000000002,-0.1509948,44.3,1.5675935793632965,8.482195078241869,4.976403910100817e-10,0.3187155566412297,221.3615376221341,-8.453806169178721,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM240-M156-60,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,240.0,212.2,1.5843599999999998,1.63,0.972,60.0,8.96,37.0,8.0,30.0,0.0044800000000000005,-0.1295,47.1,1.6656101732841384,9.000945649170486,1.8839195340856498e-09,0.2662756878617645,58.2682302423936,19.407161487995158,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM240-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,240.0,218.9,1.6367999999999998,1.65,0.992,60.0,8.96,37.5,8.0,30.0,0.007176960000000001,-0.15345,44.3,1.6236971358136045,9.013069541080093,7.804383968950344e-10,0.34369532358603155,58.02783090124362,-5.3795119738093415,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM245-M156-60,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,245.0,216.8,1.5843599999999998,1.63,0.972,60.0,9.08,37.1,8.11,30.2,0.004540000000000001,-0.12985,47.1,1.6739356838246522,9.118573900733667,2.0084456732611777e-09,0.24590480914370846,57.884112044113465,19.903326843971037,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM245-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,245.0,223.6,1.6367999999999998,1.65,0.992,60.0,9.08,37.6,8.01,30.6,0.007273080000000001,-0.1538592,44.3,1.6593385728138366,9.12979557681535,1.2025086254943064e-09,0.2602911679051389,47.46293015977925,-2.057468875892201,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM250-M156-60,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,250.0,221.3,1.5843599999999998,1.63,0.972,60.0,9.2,37.2,8.22,30.4,0.0046,-0.1302,47.1,1.6822564167255025,9.236168678625068,2.1396190505347295e-09,0.22608960967648456,57.50900471678697,20.396216836386998,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM250-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,250.0,228.3,1.6367999999999998,1.65,0.992,60.0,9.19,37.7,8.12,30.8,0.00736119,-0.15426840000000003,44.3,1.6663068676544597,9.236025873244035,1.2620279660681164e-09,0.24065469644459753,48.05159948113241,-1.7685979516469117,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM250-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,250.0,220.8,1.881792,1.936,0.972,72.0,7.87,43.8,7.22,34.6,0.0047220000000000005,-0.15768,47.1,1.9091247476915905,7.895579362406357,8.282924287364575e-10,0.5168609969484034,159.02261200855432,9.502693955842881,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM255-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,255.0,232.9,1.6367999999999998,1.65,0.992,60.0,9.22,37.8,8.23,31.0,0.0073852200000000005,-0.1546776,44.3,1.6639577230912208,9.257179282181603,1.1688230606616987e-09,0.22572279997641972,55.976453998861764,-2.4291792206116405,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM255-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,255.0,225.3,1.881792,1.936,0.972,72.0,7.98,43.9,7.34,34.7,0.004788000000000001,-0.15803999999999999,47.1,1.9114309384356265,8.00333503070112,8.219475434478761e-10,0.5074926958893559,173.5499219939259,9.303122087886065,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM260-P156-60,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,260.0,237.6,1.6367999999999998,1.65,0.992,60.0,9.37,37.9,8.34,31.2,0.00750537,-0.1550868,44.3,1.6756094174957772,9.406444581388547,1.3053932277214666e-09,0.20501348388831336,52.70952275721217,-1.6662160983728245,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM260-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,260.0,229.8,1.881792,1.936,0.972,72.0,8.08,44.0,7.47,34.8,0.004848,-0.15839999999999999,47.1,1.9111145573049653,8.098630058458323,7.916175105385379e-10,0.49902129254602334,216.4294489122781,8.843886310163251,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM265-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,265.0,233.8,1.881792,1.936,0.972,72.0,8.19,44.1,7.59,34.9,0.0040950000000000005,-0.15435,47.1,1.9138983147995179,8.20646559185015,7.897173837361908e-10,0.4900745265979913,243.76358799511414,11.9391100997771,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM265-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,265.0,234.4,1.881792,1.936,0.972,72.0,8.19,44.1,7.59,34.9,0.004914,-0.15875999999999998,47.1,1.9136314369782161,8.206474836394744,7.871772114430373e-10,0.490144711379399,243.66169473539048,8.66734220917474,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM270-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,270.0,238.3,1.881792,1.936,0.972,72.0,8.14,44.8,7.71,35.0,0.004070000000000001,-0.15679999999999997,47.1,1.9195636592335046,8.140004391859504,5.953616528263885e-10,0.5388946605267811,999999.950946389,9.403229206292538,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM270-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,270.0,238.9,1.881792,1.936,0.972,72.0,8.2,44.2,7.71,35.0,0.004919999999999999,-0.15912,47.1,1.9038506848723749,8.202453844934954,6.758919985439994e-10,0.48727181548617343,1628.3167308973245,7.274341377415282,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM275-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,275.0,242.9,1.881792,1.936,0.972,72.0,8.3,44.3,7.83,35.1,0.00415,-0.15505,47.1,1.9065304709343032,8.306201982026932,6.732338463487456e-10,0.47883075804515546,999999.9830158603,10.316549893592931,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM275-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,275.0,249.4,1.9403519999999999,1.956,0.992,72.0,8.3,44.3,7.83,35.1,0.0066649,-0.18189580000000002,45.3,1.8489405817743638,8.300806152876762,3.259215302312739e-10,0.4937109289941775,5083.172312393265,-11.740356845593677,-0.4308,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM280-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,280.0,247.4,1.881792,1.936,0.972,72.0,8.33,44.8,7.95,35.2,0.004165,-0.15679999999999997,47.1,1.9317241220388417,8.330003813914454,7.056802401229078e-10,0.45732511846920904,999991.8267019786,10.711554738370676,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM280-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,280.0,254.0,1.9403519999999999,1.956,0.992,72.0,8.41,44.4,7.88,35.5,0.006753230000000001,-0.1823064,45.3,1.8704234725902145,8.417743549959603,4.0843277078801014e-10,0.4401333427735098,478.01364893894805,-10.18729305412207,-0.4308,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM285-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,285.0,252.0,1.881792,1.936,0.972,72.0,8.51,44.5,8.0,35.6,0.004255,-0.15575,47.1,1.9288912150176054,8.513357097928077,8.103541583457707e-10,0.41866403590125273,1061.2843639135913,11.778907886140106,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM285-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,285.0,258.6,1.9403519999999999,1.956,0.992,72.0,8.51,44.5,8.0,35.6,0.006833529999999999,-0.18271700000000002,45.3,1.8718960916462344,8.514839359038545,4.007180441964342e-10,0.4330524273969117,761.5218158493501,-10.420035814714268,-0.4308,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM290-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,290.0,256.5,1.881792,1.936,0.972,72.0,8.61,44.6,8.12,35.7,0.004305,-0.1561,47.1,1.9305726540985804,8.610580423137298,7.972841861084286e-10,0.4119374258975617,6110.725616689437,11.514556864340587,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM290-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,290.0,263.3,1.9403519999999999,1.956,0.992,72.0,8.61,44.6,8.12,35.7,0.006913829999999999,-0.1831276,45.3,1.873465394973326,8.611980192038247,3.9355683193304e-10,0.42613814626087976,1852.8778083330596,-10.643521273082627,-0.4308,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM295-M156-72,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,295.0,261.1,1.881792,1.936,0.972,72.0,8.71,44.7,8.24,35.8,0.004355,-0.15645,47.1,1.9346252306951317,8.731018021468287,8.064547347358324e-10,0.40433272908899764,999999.9344969564,11.490720590458983,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM295-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,295.0,268.0,1.9403519999999999,1.956,0.992,72.0,8.71,44.7,8.24,35.8,0.00699413,-0.18353820000000004,45.3,1.8759155890633885,8.717899293037778,3.907351710324342e-10,0.41901656453166997,999999.9835792518,-10.790372111034866,-0.4308,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM300-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,300.0,272.6,1.9403519999999999,1.956,0.992,72.0,8.81,44.8,8.36,35.9,0.0070744300000000005,-0.1839488,45.3,1.8802500584283333,8.844260553195378,3.9709149249413136e-10,0.41123405264221,999999.9836628673,-10.774988044574656,-0.4308,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM305-P156-72,Hengdian Group DMEGC Magnetics Co Ltd,Multi-c-Si,0,305.0,277.3,1.9403519999999999,1.956,0.992,72.0,8.91,44.9,8.48,36.0,0.00715473,-0.1843594,45.3,1.8921696852118888,8.910003326986672,4.408998791399852e-10,0.373161762617876,999999.8633591083,-10.07229709175821,-0.4308,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM405M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,405.0,380.2,1.95,,,54.0,13.53,38.4,12.75,31.8,0.0060885,-0.092544,46.9,1.328899151384982,13.547159731697903,3.750518031238958e-12,0.18898158701374973,149.00704277922836,1.494104067308235,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM410M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,410.0,385.0,1.95,,,54.0,13.6,38.6,12.82,32.0,0.0061200000000000004,-0.093026,46.9,1.336315306862958,13.616700044872694,3.811493561765022e-12,0.1859353293107117,151.41998127683468,1.585088554314164,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM415M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,415.0,389.8,1.95,,,54.0,13.67,38.8,12.89,32.2,0.006151500000000001,-0.09350799999999998,46.9,1.3437306193470577,13.686249702215084,3.872820578046082e-12,0.18292283227160305,153.88313495434878,1.6749842592569062,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM420M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,420.0,394.6,1.95,,,54.0,13.74,39.0,12.96,32.4,0.006182999999999999,-0.09399,46.9,1.3511448506084627,13.755808316795033,3.9344753364351756e-12,0.17994359264809545,156.40026837851448,1.7637665069236066,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM425M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,425.0,399.4,1.99,,,54.0,13.82,39.3,12.92,32.9,0.006495400000000001,-0.091176,46.7,1.3738259397769161,13.84255070878804,5.066719673161638e-12,0.15762515278843933,96.59916389211963,7.9306086773341375,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM425M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,425.0,399.4,1.95,,,54.0,13.81,39.2,13.03,32.6,0.0062144999999999995,-0.094472,46.9,1.3585582450953664,13.825375919410426,3.996472509488974e-12,0.17699700898072884,158.97122195233726,1.8514947370123203,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM430M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,430.0,404.2,1.99,,,54.0,13.89,39.5,12.99,33.1,0.0065283,-0.09164000000000001,46.7,1.3812423562211755,13.911982671060887,5.1390543243879006e-12,0.15479110155551318,97.80651301012844,8.010503410998771,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM430M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,430.0,404.2,1.95,,,54.0,13.88,39.4,13.1,32.8,0.006246,-0.094954,46.9,1.365970774870046,13.894952320651416,4.058805109525958e-12,0.17408256043732426,161.59805996856625,1.9381727699576745,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM435M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,435.0,409.0,1.99,,,54.0,13.96,39.7,13.06,33.3,0.0065612,-0.092104,46.7,1.3886578953408661,13.981425325621336,5.2116893493191585e-12,0.1519880450144723,99.03014534138693,8.089433232751716,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM435M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,435.0,409.0,1.95,,,54.0,13.95,39.6,13.17,33.0,0.006277499999999999,-0.095436,46.9,1.3733824235941263,13.96453734804366,4.1214674214654685e-12,0.1711997195107972,164.28278961672356,2.0238358363283853,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM440M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,440.0,413.8,1.99,,,54.0,14.03,39.9,13.13,33.5,0.0065941,-0.09256800000000001,46.7,1.3960725631771445,14.050878480681591,5.2846201298990295e-12,0.1492154781546704,100.2703784457962,8.16741295716978,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM440M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,440.0,413.9,1.95,,,54.0,14.02,39.8,13.24,33.2,0.0063089999999999995,-0.09591799999999999,46.9,1.3807932278944708,14.034130854891789,4.184457569357087e-12,0.16834797906028043,167.02730922264735,2.108479897750784,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM445M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,445.0,418.6,1.99,,,54.0,14.1,40.1,13.2,33.7,0.006626999999999999,-0.093032,46.7,1.4034863847941892,14.120341943803439,5.357844260969601e-12,0.14647290274651018,101.5275605435553,8.244462087425733,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM445M10T-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,445.0,418.7,1.95,,,54.0,14.09,40.0,13.31,33.5,0.0063405,-0.0964,46.9,1.3901768509865622,14.10320171859384,4.423944480511699e-12,0.15697719524997727,167.5395355008937,2.536355314470898,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM450M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,450.0,423.5,1.99,,,54.0,14.17,40.3,13.27,33.9,0.0066599,-0.093496,46.7,1.4108993692124847,14.189815528619807,5.431357656294827e-12,0.14375983452887484,102.80204460683699,8.320595982515579,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM455M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,455.0,428.3,1.99,,,54.0,14.24,40.5,13.34,34.1,0.0066928,-0.09396000000000002,46.7,1.4183115351995979,14.259299056916054,5.5051573461857935e-12,0.14107579808342272,104.0941728517364,8.395831091888432,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM460M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,460.0,433.1,1.99,,,54.0,14.31,40.7,13.41,34.3,0.0067257,-0.09442400000000001,46.7,1.4257226583621632,14.328792361132896,5.579213303586231e-12,0.13842036931883073,105.4042902223559,8.470140902255688,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM465M10RT-B54yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,465.0,438.0,1.99,,,54.0,14.38,40.9,13.48,34.5,0.006758600000000001,-0.094888,46.7,1.4331334662436581,14.398295239652539,5.6536020389154385e-12,0.13579297141555025,106.73284237270714,8.543668495100512,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM555M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,555.0,521.4,2.58,,,72.0,13.69,51.5,12.94,42.9,0.0057498,-0.12257,46.6,1.7861977393235908,13.703075873405709,4.057584307832486e-12,0.22814255224452773,238.85758513970546,3.383816215061543,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM560M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,560.0,526.2,2.58,,,72.0,13.75,51.7,13.0,43.1,0.005775000000000001,-0.123046,46.6,1.793587542236837,13.762761372480407,4.1060800304299405e-12,0.22511430769262808,242.55398394944544,3.446978610417091,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM565M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,565.0,531.1,2.58,,,72.0,13.81,51.9,13.06,43.3,0.0058002,-0.12352199999999999,46.6,1.8009768959573638,13.822452273452852,4.154790250264537e-12,0.22211430258764772,246.3324095317261,3.5095921185511805,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM570M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,570.0,535.9,2.58,,,72.0,13.87,52.1,13.12,43.5,0.0058254,-0.123998,46.6,1.808365809415122,13.882148501763302,4.2037137496348674e-12,0.21914214299834972,250.19558683047427,3.571664139592877,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM575M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,575.0,540.7,2.58,,,72.0,13.93,52.3,13.18,43.7,0.005850600000000001,-0.124474,46.6,1.8157542790648982,13.941849976582652,4.252848543093232e-12,0.2161974440568261,254.14652733266806,3.6332007076000656,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM580M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,580.0,545.5,2.58,,,72.0,13.99,52.5,13.24,43.9,0.0058758000000000005,-0.12495,46.6,1.823142319259025,14.001556629616026,4.3021937855070885e-12,0.21327982533239637,258.18814476583503,3.6942097315687614,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM585M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,585.0,550.4,2.58,,,72.0,14.05,52.7,13.3,44.0,0.005901000000000001,-0.125426,46.6,1.8285696459591383,14.061577560039897,4.220361031942909e-12,0.21894190874643843,265.6979370505406,3.491960092262115,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM590M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,590.0,555.2,2.58,,,72.0,14.11,52.9,13.36,44.2,0.0059262,-0.12590200000000001,46.6,1.8359583670032324,14.121288935849721,4.269278008941372e-12,0.2160377423786304,270.0247916051499,3.5531266988800816,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM595M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,595.0,560.0,2.58,,,72.0,14.17,53.1,13.42,44.4,0.0059514,-0.126378,46.6,1.8433466715873412,14.18100533171909,4.31840419404345e-12,0.2131599249497843,274.45571158376146,3.6137758544959957,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM600G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,600.0,564.0,2.7,,,66.0,15.87,48.3,14.97,40.1,0.0076176,-0.113022,46.6,1.685496519955407,15.887775648125345,5.5986604872967735e-12,0.19301237989624984,172.32038172692918,6.601985218685041,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B72yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,600.0,564.8,2.58,,,72.0,14.23,53.3,13.47,44.6,0.005976600000000001,-0.126854,46.6,1.8513542910522645,14.241447580350975,4.406232173923454e-12,0.21026728556327762,261.3743161331278,3.752353968887034,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM600M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,600.0,563.7,2.79,,,78.0,13.7,56.1,12.95,46.3,0.005754,-0.13800600000000002,46.4,1.9472944240581398,13.713977091027692,4.1597679882536825e-12,0.284567947958857,278.926486751616,0.19540506864863907,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM605G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,605.0,568.9,2.7,,,66.0,15.93,48.5,15.03,40.3,0.0076464,-0.11349000000000001,46.6,1.6929802553562365,15.947395114076954,5.669072105693624e-12,0.19051147565915724,174.46553088714762,6.6779436141137225,-0.299,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hengdian Group DMEGC Magnetics Co Ltd DM605M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,605.0,568.5,2.79,,,78.0,13.75,56.3,13.0,46.5,0.005775000000000001,-0.13849799999999998,46.4,1.9547540896951052,13.763691230703662,4.207643183127626e-12,0.28147814153986106,282.68638067903476,0.25920894104954706,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM610G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,610.0,573.7,2.7,,,66.0,15.99,48.7,15.09,40.5,0.007675200000000001,-0.11395800000000002,46.6,1.7004631776737256,16.00702059035359,5.739770978735115e-12,0.18803095082314744,176.64574765815962,6.753137571469026,-0.299,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hengdian Group DMEGC Magnetics Co Ltd DM610M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,610.0,573.3,2.79,,,78.0,13.81,56.5,13.06,46.7,0.0058002,-0.13899,46.4,1.9621764680862892,13.82337097124105,4.256722700392839e-12,0.27821119937279454,287.3461172533253,0.3182569710976631,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM615G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,615.0,578.5,2.7,,,66.0,16.05,48.9,15.15,40.7,0.007704,-0.114426,46.6,1.7079452332586922,16.066651997952196,5.810749382675927e-12,0.18557054018564148,178.8618508117067,6.8276344336528805,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM615M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,615.0,578.1,2.79,,,78.0,13.87,56.7,13.12,46.9,0.0058254,-0.13948200000000002,46.4,1.9695985374114051,13.88305587127515,4.306037920395056e-12,0.2749745176786969,292.1211834098397,0.37684944558335387,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM620M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,620.0,582.9,2.79,,,78.0,13.93,56.9,13.18,47.1,0.005850600000000001,-0.139974,46.4,1.9770202904277347,13.942745855190502,4.355587032994821e-12,0.2717676795909085,297.01606743966965,0.43499045807026704,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM625G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,625.0,588.2,2.7,,,66.0,16.17,49.3,15.25,41.1,0.0077616000000000004,-0.115362,46.6,1.7239278295422735,16.187462435944358,6.0460193944574e-12,0.18066014232280214,167.28905443093407,7.116366509462683,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM625M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,625.0,587.8,2.79,,,78.0,13.99,57.1,13.24,47.3,0.0058758000000000005,-0.140466,46.4,1.9844417346186627,14.002440856971793,4.4053691182928655e-12,0.2685902735944042,302.03529741859194,0.4926857311724464,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM630G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,630.0,593.0,2.7,,,66.0,16.23,49.5,15.3,41.3,0.0077904,-0.11583,46.6,1.7319214541517884,16.24784191894311,6.165926228497205e-12,0.17822856456302577,162.12659760749548,7.259312172191133,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM630M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,630.0,592.6,2.79,,,78.0,14.04,57.3,13.29,47.5,0.005896800000000001,-0.140958,46.4,1.991898887966393,14.052177382319817,4.454319379999722e-12,0.26563014052355854,306.26017115098944,0.5540371029631722,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM635G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,635.0,597.9,2.7,,,66.0,16.29,49.7,15.35,41.5,0.0078192,-0.11629800000000001,46.6,1.7399165987879393,16.308204559152774,6.2873550925351594e-12,0.17581253209829512,157.322466751278,7.401321670967045,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM635M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,635.0,597.4,2.79,,,78.0,14.09,57.5,13.34,47.7,0.0059178,-0.14145000000000002,46.4,1.9993554740165447,14.101917823117436,4.503469246211917e-12,0.26269263058755915,310.5717504379561,0.6148954420519542,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM640G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,640.0,602.7,2.7,,,66.0,16.33,49.9,15.39,41.6,0.007838399999999999,-0.11676600000000001,46.6,1.745464229251069,16.348469790812803,6.1565771484208964e-12,0.18105507604535526,160.0792031738258,7.192646208410918,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM640M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,640.0,602.3,2.79,,,78.0,14.14,57.7,13.39,47.9,0.0059388,-0.141942,46.4,2.0068115376469597,14.151662156927326,4.552819828367048e-12,0.25977747898346126,314.9720582883644,0.6752708127158482,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM645G12RT-B66yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,645.0,607.5,2.7,,,66.0,16.37,50.1,15.43,41.8,0.007857600000000001,-0.117234,46.6,1.7530043039021987,16.388148307498433,6.227306828235249e-12,0.17888562553750753,161.35706840195846,7.27152640683385,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Hengdian Group DMEGC Magnetics Co Ltd DM645M10T-B78yyy,Hengdian Group DMEGC Magnetics Co Ltd,Mono-c-Si,0,645.0,607.1,2.79,,,78.0,14.19,57.9,13.44,48.1,0.0059598,-0.14243399999999998,46.4,2.0142669493786025,14.201410249485034,4.602361398003032e-12,0.2568844522760876,319.4663152520301,0.7351518854386825,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-390/M,Hounen Solar America Inc,Mono-c-Si,0,390.0,362.0,1.94,,,54.0,13.56,36.7,12.79,30.5,0.006752879999999999,-0.10690710000000002,46.37,1.3750332996789765,13.570981526967621,3.426873435784556e-11,0.1525673162963141,188.39027012199986,0.36301016311796047,-0.3483,N,2025.7.3,6/23/2025,4.0,bootstrapping +Hounen Solar America Inc HNM7-SHDB108-390/M,Hounen Solar America Inc,Mono-c-Si,1,390.0,362.1,1.94,,,54.0,13.54,36.7,12.79,30.5,0.0075823999999999996,-0.09780550000000002,46.08,1.3815330634249607,13.549294034261449,3.8873907118899184e-11,0.1515929732164933,220.84800140557843,10.821321171137768,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-395/M,Hounen Solar America Inc,Mono-c-Si,0,395.0,366.8,1.94,,,54.0,13.63,36.9,12.87,30.7,0.00678774,-0.1074897,46.37,1.3825782181285924,13.639890256585222,3.452031511299121e-11,0.14965132427696937,206.23808455484803,0.37674882946942717,-0.3483,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB108-395/M,Hounen Solar America Inc,Mono-c-Si,1,395.0,366.8,1.94,,,54.0,13.62,36.9,12.87,30.7,0.0076272,-0.09833850000000001,46.08,1.3896118011180354,13.628920906462643,3.9528600433859434e-11,0.14851976780422715,226.75265967513002,10.917390067974583,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-400/M,Hounen Solar America Inc,Mono-c-Si,0,400.0,371.6,1.94,,,54.0,13.7,37.1,12.95,30.9,0.006822599999999999,-0.1080723,46.37,1.390122148586519,13.708838157133764,3.4771329191546025e-11,0.1467721757250181,227.51109799265615,0.39016399944654523,-0.3483,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB108-400/M,Hounen Solar America Inc,Mono-c-Si,1,400.0,371.6,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007671999999999999,-0.0988715,46.08,1.3976896207390601,13.70855778536917,4.018721689659721e-11,0.14548522145248718,232.90459829115468,11.012257539325056,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-405/M,Hounen Solar America Inc,Mono-c-Si,0,405.0,376.3,1.94,,,54.0,13.77,37.3,13.03,31.1,0.006857459999999999,-0.1086549,46.37,1.3976651113330052,13.77782433242055,3.502178566341581e-11,0.1439291734819627,253.30017186004122,0.40326746484812626,-0.3483,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB108-405/M,Hounen Solar America Inc,Mono-c-Si,1,405.0,376.4,1.94,,,54.0,13.78,37.3,13.03,31.1,0.0077168,-0.0994045,46.08,1.4057665343234662,13.788204478616187,4.084971467180525e-11,0.14248860611549954,239.31965867525523,11.10595261005917,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-410/M,Hounen Solar America Inc,Mono-c-Si,0,410.0,381.1,1.94,,,54.0,13.84,37.5,13.1,31.3,0.0068923199999999995,-0.1092375,46.37,1.4057373937445226,13.84751982508751,3.559663718073847e-11,0.1410662766452096,259.62801976363806,0.4936585070306611,-0.3483,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB108-410/M,Hounen Solar America Inc,Mono-c-Si,1,410.0,381.2,1.94,,,54.0,13.86,37.5,13.1,31.3,0.0077616000000000004,-0.09993750000000001,46.08,1.4143671872399837,13.868526217529189,4.188890560025164e-11,0.13947302964740504,226.7237743819982,11.282390048429649,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-415/M,Hounen Solar America Inc,Mono-c-Si,0,415.0,385.9,1.94,,,54.0,13.91,37.7,13.18,31.5,0.00692718,-0.10982010000000002,46.37,1.4132776345362266,13.916565863967353,3.5845998962657146e-11,0.13829199656456692,292.976173669143,0.5056379105046853,-0.3483,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB108-415/M,Hounen Solar America Inc,Mono-c-Si,1,415.0,386.0,1.94,,,54.0,13.94,37.7,13.18,31.5,0.0078064,-0.10047050000000002,46.08,1.4224425023806744,13.948177364205435,4.256290196716632e-11,0.1365481758963711,232.77446766906468,11.373397467021684,-0.3524,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SH108-420/M,Hounen Solar America Inc,Mono-c-Si,0,420.0,390.7,1.94,,,54.0,13.98,37.9,13.25,31.7,0.00696204,-0.1104027,46.37,1.4213470777655346,13.986291317800655,3.6423437023464544e-11,0.13549292526786685,301.0801637340061,0.5941043985895367,-0.3483,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB144-530/M,Hounen Solar America Inc,Mono-c-Si,1,530.0,495.8,2.58,,,72.0,13.65,49.4,12.91,41.1,0.008558550000000002,-0.1297738,45.45,1.825021643902791,13.659084267118946,2.3698342768643734e-11,0.2043445369897349,307.0476594802032,7.849894252346879,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB144-535/M,Hounen Solar America Inc,Mono-c-Si,1,535.0,500.6,2.58,,,72.0,13.71,49.6,12.96,41.3,0.00859617,-0.1302992,45.45,1.8336183292792658,13.719532075598224,2.421405316477722e-11,0.20125701220443315,289.468294143714,8.002947922670463,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB144-540/M,Hounen Solar America Inc,Mono-c-Si,1,540.0,505.4,2.58,,,72.0,13.77,49.8,13.02,41.5,0.00863379,-0.13082459999999999,45.45,1.8415394970758652,13.77925367471999,2.451456713821459e-11,0.19825399608801342,295.0133471115701,8.072248382433294,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB144-545/M,Hounen Solar America Inc,Mono-c-Si,1,545.0,510.2,2.58,,,72.0,13.83,50.0,13.07,41.7,0.008671410000000001,-0.13135,45.45,1.850137185916454,13.839678183336849,2.5040694782159164e-11,0.1952157580689703,278.96082134850235,8.223318349783264,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB144-550/M,Hounen Solar America Inc,Mono-c-Si,1,550.0,515.0,2.58,,,72.0,13.89,50.2,13.13,41.9,0.008709030000000001,-0.1318754,45.45,1.8580571493671636,13.899399566075704,2.5345600293616633e-11,0.19226636155338703,284.1173494743571,8.29104082507539,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-SHDB144-555/M,Hounen Solar America Inc,Mono-c-Si,1,555.0,519.8,2.58,,,72.0,13.95,50.4,13.19,42.1,0.00874665,-0.13240079999999999,45.45,1.8659764515411663,13.959126380476071,2.5651803658228375e-11,0.18934426960031928,289.4195135464979,8.358141289268136,-0.3301,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-UHLDD144-560/N,Hounen Solar America Inc,Mono-c-Si,1,560.0,525.9,2.58,,,72.0,14.11,50.7,13.34,42.0,0.007464190000000001,-0.1265472,46.23,1.797435100805964,14.122513224003502,7.830463525733981e-12,0.23048133194200515,259.89238361119783,3.597181486425358,-0.3067,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-UHLDD144-565/N,Hounen Solar America Inc,Mono-c-Si,1,565.0,530.7,2.58,,,72.0,14.17,50.9,13.39,42.2,0.00749593,-0.1270464,46.23,1.805657618799069,14.18302354207097,7.998740424256365e-12,0.22746556298250348,247.48927954506473,3.7443995978952804,-0.3067,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-UHLDD144-570/N,Hounen Solar America Inc,Mono-c-Si,1,570.0,535.5,2.58,,,72.0,14.23,51.1,13.45,42.4,0.007527670000000001,-0.1275456,46.23,1.8132609247667857,14.242703593738508,8.098052538288808e-12,0.22449852528589476,251.47325149323274,3.8127273657545113,-0.3067,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-UHLDD144-575/N,Hounen Solar America Inc,Mono-c-Si,1,575.0,540.3,2.58,,,72.0,14.29,51.3,13.5,42.6,0.00755941,-0.1280448,46.23,1.8214845195773948,14.30319060233491,8.269760371215331e-12,0.22152950892689616,239.9933385541545,3.9580992795020506,-0.3067,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-UHLDD144-580/N,Hounen Solar America Inc,Mono-c-Si,1,580.0,545.1,2.58,,,72.0,14.35,51.5,13.56,42.8,0.00759115,-0.128544,46.23,1.829086772049236,14.362870436482156,8.370556604395705e-12,0.2186136197760132,243.74507130835983,4.024933027874104,-0.3067,N,2025.7.3,6/23/2025,4.0,first_pass +Hounen Solar America Inc HNM7-UHLDD144-585/N,Hounen Solar America Inc,Mono-c-Si,1,585.0,550.0,2.58,,,72.0,14.41,51.7,13.61,43.0,0.007622890000000001,-0.1290432,46.23,1.837311418269835,14.423334706814208,8.545699693954363e-12,0.21569023440394172,233.08321134402036,4.1684970229764255,-0.3067,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-390,Hyperion Solar,Mono-c-Si,1,390.0,362.1,1.95,,,54.0,13.61,36.85,12.73,30.64,0.0076367071,-0.11324005000000001,43.7,1.4739278922972021,13.624695393188418,1.8492231556555188e-10,0.13575738197572165,125.73042470736434,8.872487354443196,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-390-B,Hyperion Solar,Mono-c-Si,1,390.0,362.1,1.95,,,54.0,13.61,36.85,12.73,30.64,0.0076367071,-0.11324005000000001,43.7,1.4739278922972021,13.624695393188418,1.8492231556555188e-10,0.13575738197572165,125.73042470736434,8.872487354443196,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-390-T,Hyperion Solar,Mono-c-Si,1,390.0,362.1,1.95,,,54.0,13.61,36.85,12.73,30.64,0.0076367071,-0.11324005000000001,43.7,1.4739278922972021,13.624695393188418,1.8492231556555188e-10,0.13575738197572165,125.73042470736434,8.872487354443196,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-390,Hyperion Solar,Mono-c-Si,0,390.0,361.4,1.95,,,54.0,13.61,36.85,12.73,30.64,0.009682153999999998,-0.109772465,44.0,1.4951230397581396,13.623802543266345,2.6376720754471607e-10,0.1321761930874453,130.33236519994063,15.419955651027324,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-390-B {Blk},Hyperion Solar,Mono-c-Si,0,390.0,361.4,1.95,,,54.0,13.61,36.85,12.73,30.64,0.009682153999999998,-0.109772465,44.0,1.4951230397581396,13.623802543266345,2.6376720754471607e-10,0.1321761930874453,130.33236519994063,15.419955651027324,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-390-b {Wht} ,Hyperion Solar,Mono-c-Si,0,390.0,361.4,1.95,,,54.0,13.61,36.85,12.73,30.64,0.009682153999999998,-0.109772465,44.0,1.4951230397581396,13.623802543266345,2.6376720754471607e-10,0.1321761930874453,130.33236519994063,15.419955651027324,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-395,Hyperion Solar,Mono-c-Si,1,395.0,366.9,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007687206999999999,-0.11363954,43.7,1.4818235359628038,13.714286664286782,1.946732145942045e-10,0.12695010270679455,121.73705675124035,9.26906464539569,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-395-B,Hyperion Solar,Mono-c-Si,1,395.0,366.9,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007687206999999999,-0.11363954,43.7,1.4818235359628038,13.714286664286782,1.946732145942045e-10,0.12695010270679455,121.73705675124035,9.26906464539569,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-395-T,Hyperion Solar,Mono-c-Si,1,395.0,366.9,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007687206999999999,-0.11363954,43.7,1.4818235359628038,13.714286664286782,1.946732145942045e-10,0.12695010270679455,121.73705675124035,9.26906464539569,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-395,Hyperion Solar,Mono-c-Si,0,395.0,366.2,1.95,,,54.0,13.7,36.98,12.81,30.84,0.009746179999999998,-0.11015972199999999,44.0,1.5031136569358747,13.713411992938367,2.774108098560886e-10,0.12336726996075226,126.01644515519645,15.832695054163471,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-395-B {Blk},Hyperion Solar,Mono-c-Si,0,395.0,366.2,1.95,,,54.0,13.7,36.98,12.81,30.84,0.009746179999999998,-0.11015972199999999,44.0,1.5031136569358747,13.713411992938367,2.774108098560886e-10,0.12336726996075226,126.01644515519645,15.832695054163471,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-395-b {Wht},Hyperion Solar,Mono-c-Si,0,395.0,366.2,1.95,,,54.0,13.7,36.98,12.81,30.84,0.009746179999999998,-0.11015972199999999,44.0,1.5031136569358747,13.713411992938367,2.774108098560886e-10,0.12336726996075226,126.01644515519645,15.832695054163471,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-400,Hyperion Solar,Mono-c-Si,1,400.0,371.7,1.95,,,54.0,13.79,37.07,12.9,31.01,0.0077377068999999995,-0.11391611000000001,43.7,1.4875879625724984,13.803224117517166,2.032231166166415e-10,0.11791052984649021,122.95612582031131,9.590111437680722,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-400-B,Hyperion Solar,Mono-c-Si,1,400.0,371.7,1.95,,,54.0,13.79,37.07,12.9,31.01,0.0077377068999999995,-0.11391611000000001,43.7,1.4875879625724984,13.803224117517166,2.032231166166415e-10,0.11791052984649021,122.95612582031131,9.590111437680722,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-400-T,Hyperion Solar,Mono-c-Si,1,400.0,371.7,1.95,,,54.0,13.79,37.07,12.9,31.01,0.0077377068999999995,-0.11391611000000001,43.7,1.4875879625724984,13.803224117517166,2.032231166166415e-10,0.11791052984649021,122.95612582031131,9.590111437680722,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-400,Hyperion Solar,Mono-c-Si,0,400.0,371.0,1.95,,,54.0,13.79,37.07,12.9,31.01,0.009810205999999998,-0.11042782300000001,44.0,1.5089455285205424,13.802385151587961,2.8937250352930926e-10,0.11433383901320761,127.30273801004094,16.166981489533534,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-400-B {Blk},Hyperion Solar,Mono-c-Si,0,400.0,371.0,1.95,,,54.0,13.79,37.07,12.9,31.01,0.009810205999999998,-0.11042782300000001,44.0,1.5089455285205424,13.802385151587961,2.8937250352930926e-10,0.11433383901320761,127.30273801004094,16.166981489533534,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-400-b {Wht},Hyperion Solar,Mono-c-Si,0,400.0,371.0,1.95,,,54.0,13.79,37.07,12.9,31.01,0.009810205999999998,-0.11042782300000001,44.0,1.5089455285205424,13.802385151587961,2.8937250352930926e-10,0.11433383901320761,127.30273801004094,16.166981489533534,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-405,Hyperion Solar,Mono-c-Si,1,405.0,376.5,1.95,,,54.0,13.87,37.23,12.98,31.21,0.0077825957,-0.11440779,43.7,1.4954413002362947,13.882452858894048,2.0939537024950536e-10,0.11185369427635515,124.58270035983557,9.80294278050202,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-405-B,Hyperion Solar,Mono-c-Si,1,405.0,376.5,1.95,,,54.0,13.87,37.23,12.98,31.21,0.0077825957,-0.11440779,43.7,1.4954413002362947,13.882452858894048,2.0939537024950536e-10,0.11185369427635515,124.58270035983557,9.80294278050202,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-405-T,Hyperion Solar,Mono-c-Si,1,405.0,376.5,1.95,,,54.0,13.87,37.23,12.98,31.21,0.0077825957,-0.11440779,43.7,1.4954413002362947,13.882452858894048,2.0939537024950536e-10,0.11185369427635515,124.58270035983557,9.80294278050202,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-405,Hyperion Solar,Mono-c-Si,0,405.0,375.8,1.95,,,54.0,13.87,37.23,12.98,31.21,0.009867118,-0.11090444699999999,44.0,1.5169009468610368,13.881639424750409,2.980083700148385e-10,0.10827690755102956,129.0270614542687,16.388550388913043,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-405-B {Blk},Hyperion Solar,Mono-c-Si,0,405.0,375.8,1.95,,,54.0,13.87,37.23,12.98,31.21,0.009867118,-0.11090444699999999,44.0,1.5169009468610368,13.881639424750409,2.980083700148385e-10,0.10827690755102956,129.0270614542687,16.388550388913043,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH108P8-405-b {Wht},Hyperion Solar,Mono-c-Si,0,405.0,375.8,1.95,,,54.0,13.87,37.23,12.98,31.21,0.009867118,-0.11090444699999999,44.0,1.5169009468610368,13.881639424750409,2.980083700148385e-10,0.10827690755102956,129.0270614542687,16.388550388913043,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH108P8-410,Hyperion Solar,Mono-c-Si,1,410.0,381.2,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007827484499999999,-0.11468436000000001,43.7,1.504321628317669,13.961751367791834,2.2934913068910803e-10,0.0966529438808125,114.7363123326904,10.567460388962498,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH108P8-410-B,Hyperion Solar,Mono-c-Si,1,410.0,381.2,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007827484499999999,-0.11468436000000001,43.7,1.504321628317669,13.961751367791834,2.2934913068910803e-10,0.0966529438808125,114.7363123326904,10.567460388962498,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH108P8-410-T,Hyperion Solar,Mono-c-Si,1,410.0,381.2,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007827484499999999,-0.11468436000000001,43.7,1.504321628317669,13.961751367791834,2.2934913068910803e-10,0.0966529438808125,114.7363123326904,10.567460388962498,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH108P8-410,Hyperion Solar,Mono-c-Si,0,410.0,380.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.009924029999999999,-0.11117254800000001,44.0,1.5258647078826855,13.960961520325869,3.2577087313237866e-10,0.09306440226539443,118.43689787292111,17.18288909949589,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH108P8-410-B {Blk},Hyperion Solar,Mono-c-Si,0,410.0,380.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.009924029999999999,-0.11117254800000001,44.0,1.5258647078826855,13.960961520325869,3.2577087313237866e-10,0.09306440226539443,118.43689787292111,17.18288909949589,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH108P8-410-b {Wht},Hyperion Solar,Mono-c-Si,0,410.0,380.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.009924029999999999,-0.11117254800000001,44.0,1.5258647078826855,13.960961520325869,3.2577087313237866e-10,0.09306440226539443,118.43689787292111,17.18288909949589,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH108P8-415,Hyperion Solar,Mono-c-Si,1,415.0,386.0,1.95,,,54.0,14.02,37.45,13.13,31.61,0.0078667622,-0.11508385000000003,43.7,1.5093691139015812,14.030263263768651,2.3024697199651663e-10,0.09231303520042683,126.10304305629097,10.55078420202246,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH108P8-415-B,Hyperion Solar,Mono-c-Si,1,415.0,386.0,1.95,,,54.0,14.02,37.45,13.13,31.61,0.0078667622,-0.11508385000000003,43.7,1.5093691139015812,14.030263263768651,2.3024697199651663e-10,0.09231303520042683,126.10304305629097,10.55078420202246,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH108P8-415-T,Hyperion Solar,Mono-c-Si,1,415.0,386.0,1.95,,,54.0,14.02,37.45,13.13,31.61,0.0078667622,-0.11508385000000003,43.7,1.5093691139015812,14.030263263768651,2.3024697199651663e-10,0.09231303520042683,126.10304305629097,10.55078420202246,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH108P8-415,Hyperion Solar,Mono-c-Si,0,415.0,385.3,1.95,,,54.0,14.02,37.45,13.13,31.61,0.009973827999999999,-0.11155980500000001,44.0,1.530986983157635,14.02952654383378,3.270744497903931e-10,0.0887341779197542,130.58809676312598,17.16631595830447,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH108P8-415-B {Blk},Hyperion Solar,Mono-c-Si,0,415.0,385.3,1.95,,,54.0,14.02,37.45,13.13,31.61,0.009973827999999999,-0.11155980500000001,44.0,1.530986983157635,14.02952654383378,3.270744497903931e-10,0.0887341779197542,130.58809676312598,17.16631595830447,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH108P8-415-b {Wht},Hyperion Solar,Mono-c-Si,0,415.0,385.3,1.95,,,54.0,14.02,37.45,13.13,31.61,0.009973827999999999,-0.11155980500000001,44.0,1.530986983157635,14.02952654383378,3.270744497903931e-10,0.0887341779197542,130.58809676312598,17.16631595830447,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-435,Hyperion Solar,Mono-c-Si,1,435.0,404.0,2.16,,,60.0,13.61,40.77715215,12.7,34.26,0.0076367071,-0.12530818855695,43.7,1.6424833608097267,13.623441480158736,2.1937730219480964e-10,0.1174269133414533,118.89913273868208,10.396932066864942,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-435-B,Hyperion Solar,Mono-c-Si,1,435.0,404.0,2.16,,,60.0,13.61,40.77715215,12.7,34.26,0.0076367071,-0.12530818855695,43.7,1.6424833608097267,13.623441480158736,2.1937730219480964e-10,0.1174269133414533,118.89913273868208,10.396932066864942,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-435-T,Hyperion Solar,Mono-c-Si,1,435.0,404.0,2.16,,,60.0,13.61,40.77715215,12.7,34.26,0.0076367071,-0.12530818855695,43.7,1.6424833608097267,13.623441480158736,2.1937730219480964e-10,0.1174269133414533,118.89913273868208,10.396932066864942,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-440,Hyperion Solar,Mono-c-Si,1,440.0,408.8,2.16,,,60.0,13.7,40.91234369,12.79,34.41,0.007687206999999999,-0.12572363215937002,43.7,1.6484763686395782,13.712899700378403,2.2275798866654704e-10,0.1138020780431567,120.86238184183,10.473012413688952,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-440-B,Hyperion Solar,Mono-c-Si,1,440.0,408.8,2.16,,,60.0,13.7,40.91234369,12.79,34.41,0.007687206999999999,-0.12572363215937002,43.7,1.6484763686395782,13.712899700378403,2.2275798866654704e-10,0.1138020780431567,120.86238184183,10.473012413688952,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-440-T,Hyperion Solar,Mono-c-Si,1,440.0,408.8,2.16,,,60.0,13.7,40.91234369,12.79,34.41,0.007687206999999999,-0.12572363215937002,43.7,1.6484763686395782,13.712899700378403,2.2275798866654704e-10,0.1138020780431567,120.86238184183,10.473012413688952,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-445,Hyperion Solar,Mono-c-Si,1,445.0,413.5,2.16,,,60.0,13.79,41.03890504,12.87,34.58,0.0077377068999999995,-0.12611255518792003,43.7,1.6555390349087369,13.802574033076413,2.3079107878953027e-10,0.10761403754312462,118.02081386425941,10.732668059733852,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-445-B,Hyperion Solar,Mono-c-Si,1,445.0,413.5,2.16,,,60.0,13.79,41.03890504,12.87,34.58,0.0077377068999999995,-0.12611255518792003,43.7,1.6555390349087369,13.802574033076413,2.3079107878953027e-10,0.10761403754312462,118.02081386425941,10.732668059733852,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-445-T,Hyperion Solar,Mono-c-Si,1,445.0,413.5,2.16,,,60.0,13.79,41.03890504,12.87,34.58,0.0077377068999999995,-0.12611255518792003,43.7,1.6555390349087369,13.802574033076413,2.3079107878953027e-10,0.10761403754312462,118.02081386425941,10.732668059733852,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-450,Hyperion Solar,Mono-c-Si,1,450.0,418.3,2.16,,,60.0,13.87,41.20288407,12.96,34.73,0.0077825957,-0.12661646274711003,43.7,1.661403817077768,13.88184914656049,2.2986148396942428e-10,0.10655415957710536,124.72680862974491,10.64038535758826,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-450-B,Hyperion Solar,Mono-c-Si,1,450.0,418.3,2.16,,,60.0,13.87,41.20288407,12.96,34.73,0.0077825957,-0.12661646274711003,43.7,1.661403817077768,13.88184914656049,2.2986148396942428e-10,0.10655415957710536,124.72680862974491,10.64038535758826,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-450-T,Hyperion Solar,Mono-c-Si,1,450.0,418.3,2.16,,,60.0,13.87,41.20288407,12.96,34.73,0.0077825957,-0.12661646274711003,43.7,1.661403817077768,13.88184914656049,2.2986148396942428e-10,0.10655415957710536,124.72680862974491,10.64038535758826,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-455,Hyperion Solar,Mono-c-Si,1,455.0,423.1,2.16,,,60.0,13.95,41.35822664,13.04,34.9,0.007827484499999999,-0.12709383046472,43.7,1.6683367494137553,13.961339567889222,2.3358463218937547e-10,0.10292546740193424,126.61949076068102,10.731333799200305,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-455-B,Hyperion Solar,Mono-c-Si,1,455.0,423.1,2.16,,,60.0,13.95,41.35822664,13.04,34.9,0.007827484499999999,-0.12709383046472,43.7,1.6683367494137553,13.961339567889222,2.3358463218937547e-10,0.10292546740193424,126.61949076068102,10.731333799200305,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-455-T,Hyperion Solar,Mono-c-Si,1,455.0,423.1,2.16,,,60.0,13.95,41.35822664,13.04,34.9,0.007827484499999999,-0.12709383046472,43.7,1.6683367494137553,13.961339567889222,2.3358463218937547e-10,0.10292546740193424,126.61949076068102,10.731333799200305,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH120P8-460,Hyperion Solar,Mono-c-Si,1,460.0,427.9,2.16,,,60.0,14.02,41.53877824,13.13,35.04,0.0078667622,-0.12764866553152002,43.7,1.6736047012126944,14.030428699460499,2.2836744227037478e-10,0.10426569209395359,140.17136588779087,10.47747578876695,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-460-B,Hyperion Solar,Mono-c-Si,1,460.0,427.9,2.16,,,60.0,14.02,41.53877824,13.13,35.04,0.0078667622,-0.12764866553152002,43.7,1.6736047012126944,14.030428699460499,2.2836744227037478e-10,0.10426569209395359,140.17136588779087,10.47747578876695,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH120P8-460-T,Hyperion Solar,Mono-c-Si,1,460.0,427.9,2.16,,,60.0,14.02,41.53877824,13.13,35.04,0.0078667622,-0.12764866553152002,43.7,1.6736047012126944,14.030428699460499,2.2836744227037478e-10,0.10426569209395359,140.17136588779087,10.47747578876695,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-480,Hyperion Solar,Mono-c-Si,1,480.0,445.9,2.37,,,66.0,13.65,45.07,12.76,37.62,0.007659151500000001,-0.13850011,43.7,1.8071236818574037,13.664192174555145,1.969258844401044e-10,0.15222126806228556,146.40606098743646,9.404131725861147,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH132P8-480-B,Hyperion Solar,Mono-c-Si,1,480.0,445.9,2.37,,,66.0,13.65,45.07,12.76,37.62,0.007659151500000001,-0.13850011,43.7,1.8071236818574037,13.664192174555145,1.969258844401044e-10,0.15222126806228556,146.40606098743646,9.404131725861147,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH132P8-480-T,Hyperion Solar,Mono-c-Si,1,480.0,445.9,2.37,,,66.0,13.65,45.07,12.76,37.62,0.007659151500000001,-0.13850011,43.7,1.8071236818574037,13.664192174555145,1.969258844401044e-10,0.15222126806228556,146.40606098743646,9.404131725861147,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH132P8-485,Hyperion Solar,Mono-c-Si,1,485.0,450.6,2.37,,,66.0,13.72,45.2,12.83,37.81,0.0076984292000000015,-0.1388996,43.7,1.8141531868280594,13.733416193751516,2.0298436868600383e-10,0.14453706878555622,147.81007804302786,9.62609080966332,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH132P8-485-B,Hyperion Solar,Mono-c-Si,1,485.0,450.6,2.37,,,66.0,13.72,45.2,12.83,37.81,0.0076984292000000015,-0.1388996,43.7,1.8141531868280594,13.733416193751516,2.0298436868600383e-10,0.14453706878555622,147.81007804302786,9.62609080966332,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH132P8-485-T,Hyperion Solar,Mono-c-Si,1,485.0,450.6,2.37,,,66.0,13.72,45.2,12.83,37.81,0.0076984292000000015,-0.1388996,43.7,1.8141531868280594,13.733416193751516,2.0298436868600383e-10,0.14453706878555622,147.81007804302786,9.62609080966332,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH132P8-490,Hyperion Solar,Mono-c-Si,1,490.0,455.4,2.37,,,66.0,13.79,45.33,12.9,37.99,0.0077377068999999995,-0.13929909000000001,43.7,1.8209150457009124,13.802725625298011,2.0842473370889958e-10,0.1378410549150851,149.37012211013922,9.814494783367957,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-490-B,Hyperion Solar,Mono-c-Si,1,490.0,455.4,2.37,,,66.0,13.79,45.33,12.9,37.99,0.0077377068999999995,-0.13929909000000001,43.7,1.8209150457009124,13.802725625298011,2.0842473370889958e-10,0.1378410549150851,149.37012211013922,9.814494783367957,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-490-T,Hyperion Solar,Mono-c-Si,1,490.0,455.4,2.37,,,66.0,13.79,45.33,12.9,37.99,0.0077377068999999995,-0.13929909000000001,43.7,1.8209150457009124,13.802725625298011,2.0842473370889958e-10,0.1378410549150851,149.37012211013922,9.814494783367957,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-495,Hyperion Solar,Mono-c-Si,1,495.0,460.2,2.37,,,66.0,13.86,45.46,12.97,38.17,0.0077769846,-0.13969858000000002,43.7,1.8276746469206622,13.872048236179488,2.139649792781217e-10,0.13121933619705603,150.95156070355077,10.001548303460716,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-495-B,Hyperion Solar,Mono-c-Si,1,495.0,460.2,2.37,,,66.0,13.86,45.46,12.97,38.17,0.0077769846,-0.13969858000000002,43.7,1.8276746469206622,13.872048236179488,2.139649792781217e-10,0.13121933619705603,150.95156070355077,10.001548303460716,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-495-T,Hyperion Solar,Mono-c-Si,1,495.0,460.2,2.37,,,66.0,13.86,45.46,12.97,38.17,0.0077769846,-0.13969858000000002,43.7,1.8276746469206622,13.872048236179488,2.139649792781217e-10,0.13121933619705603,150.95156070355077,10.001548303460716,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-500,Hyperion Solar,Mono-c-Si,1,500.0,465.0,2.37,,,66.0,13.93,45.59,13.04,38.35,0.0078162623,-0.14009807000000002,43.7,1.834432041726014,13.941383859915138,2.196060352960314e-10,0.12467067933691664,152.55481259877877,10.18726937031969,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-500-B,Hyperion Solar,Mono-c-Si,1,500.0,465.0,2.37,,,66.0,13.93,45.59,13.04,38.35,0.0078162623,-0.14009807000000002,43.7,1.834432041726014,13.941383859915138,2.196060352960314e-10,0.12467067933691664,152.55481259877877,10.18726937031969,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-500-T,Hyperion Solar,Mono-c-Si,1,500.0,465.0,2.37,,,66.0,13.93,45.59,13.04,38.35,0.0078162623,-0.14009807000000002,43.7,1.834432041726014,13.941383859915138,2.196060352960314e-10,0.12467067933691664,152.55481259877877,10.18726937031969,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-505,Hyperion Solar,Mono-c-Si,1,505.0,469.8,2.37,,,66.0,14.0,45.72,13.11,38.53,0.007855540000000001,-0.14049756,43.7,1.8411872365386468,14.010732334490266,2.2534869585659927e-10,0.11819388559759898,154.18029045506657,10.371670185835555,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-505-B,Hyperion Solar,Mono-c-Si,1,505.0,469.8,2.37,,,66.0,14.0,45.72,13.11,38.53,0.007855540000000001,-0.14049756,43.7,1.8411872365386468,14.010732334490266,2.2534869585659927e-10,0.11819388559759898,154.18029045506657,10.371670185835555,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH132P8-505-T,Hyperion Solar,Mono-c-Si,1,505.0,469.8,2.37,,,66.0,14.0,45.72,13.11,38.53,0.007855540000000001,-0.14049756,43.7,1.8411872365386468,14.010732334490266,2.2534869585659927e-10,0.11819388559759898,154.18029045506657,10.371670185835555,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-525,Hyperion Solar,Mono-c-Si,1,525.0,487.7,2.58,,,72.0,13.65,49.15,12.76,41.15,0.007659151500000001,-0.15103795,43.7,1.974014325632289,13.663359260721915,2.0524583441920808e-10,0.15464872651617456,158.01437083515447,9.771144130464087,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-525-B,Hyperion Solar,Mono-c-Si,1,525.0,487.7,2.58,,,72.0,13.65,49.15,12.76,41.15,0.007659151500000001,-0.15103795,43.7,1.974014325632289,13.663359260721915,2.0524583441920808e-10,0.15464872651617456,158.01437083515447,9.771144130464087,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-525-T,Hyperion Solar,Mono-c-Si,1,525.0,487.7,2.58,,,72.0,13.65,49.15,12.76,41.15,0.007659151500000001,-0.15103795,43.7,1.974014325632289,13.663359260721915,2.0524583441920808e-10,0.15464872651617456,158.01437083515447,9.771144130464087,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-525,Hyperion Solar,Mono-c-Si,0,525.0,486.8,2.58,,,72.0,13.65,49.15,12.76,41.15,0.00971061,-0.146412935,44.0,2.0023424202079405,13.662522259642062,2.92117652567232e-10,0.1498489541511452,163.3441863318851,16.355012008599736,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-525-B {Blk},Hyperion Solar,Mono-c-Si,0,525.0,486.8,2.58,,,72.0,13.65,49.15,12.76,41.15,0.00971061,-0.146412935,44.0,2.0023424202079405,13.662522259642062,2.92117652567232e-10,0.1498489541511452,163.3441863318851,16.355012008599736,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-525-b {Wht},Hyperion Solar,Mono-c-Si,0,525.0,486.8,2.58,,,72.0,13.65,49.15,12.76,41.15,0.00971061,-0.146412935,44.0,2.0023424202079405,13.662522259642062,2.92117652567232e-10,0.1498489541511452,163.3441863318851,16.355012008599736,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-530,Hyperion Solar,Mono-c-Si,1,530.0,492.5,2.58,,,72.0,13.72,49.3,12.83,41.31,0.0076984292000000015,-0.15149890000000002,43.7,1.9805737280191784,13.732949209433603,2.0776097884814584e-10,0.15126713833000177,160.2711897585007,9.832644660328313,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-530-B,Hyperion Solar,Mono-c-Si,1,530.0,492.5,2.58,,,72.0,13.72,49.3,12.83,41.31,0.0076984292000000015,-0.15149890000000002,43.7,1.9805737280191784,13.732949209433603,2.0776097884814584e-10,0.15126713833000177,160.2711897585007,9.832644660328313,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-530-T,Hyperion Solar,Mono-c-Si,1,530.0,492.5,2.58,,,72.0,13.72,49.3,12.83,41.31,0.0076984292000000015,-0.15149890000000002,43.7,1.9805737280191784,13.732949209433603,2.0776097884814584e-10,0.15126713833000177,160.2711897585007,9.832644660328313,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-530,Hyperion Solar,Mono-c-Si,0,530.0,491.6,2.58,,,72.0,13.72,49.3,12.83,41.31,0.009760408,-0.14685977,44.0,2.0089919288853966,13.732124006305096,2.9565453935187175e-10,0.14647587493568506,165.7578402561252,16.419112664416964,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-530-B {Blk},Hyperion Solar,Mono-c-Si,0,530.0,491.6,2.58,,,72.0,13.72,49.3,12.83,41.31,0.009760408,-0.14685977,44.0,2.0089919288853966,13.732124006305096,2.9565453935187175e-10,0.14647587493568506,165.7578402561252,16.419112664416964,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-530-b {Wht},Hyperion Solar,Mono-c-Si,0,530.0,491.6,2.58,,,72.0,13.72,49.3,12.83,41.31,0.009760408,-0.14685977,44.0,2.0089919288853966,13.732124006305096,2.9565453935187175e-10,0.14647587493568506,165.7578402561252,16.419112664416964,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-535,Hyperion Solar,Mono-c-Si,1,535.0,497.3,2.58,,,72.0,13.79,49.45,12.9,41.47,0.0077377068999999995,-0.15195985000000004,43.7,1.987133589652071,13.802547214636663,2.102925694377315e-10,0.14792243709392255,162.57396783557607,9.893813707510583,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-535-B,Hyperion Solar,Mono-c-Si,1,535.0,497.3,2.58,,,72.0,13.79,49.45,12.9,41.47,0.0077377068999999995,-0.15195985000000004,43.7,1.987133589652071,13.802547214636663,2.102925694377315e-10,0.14792243709392255,162.57396783557607,9.893813707510583,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-535-T,Hyperion Solar,Mono-c-Si,1,535.0,497.3,2.58,,,72.0,13.79,49.45,12.9,41.47,0.0077377068999999995,-0.15195985000000004,43.7,1.987133589652071,13.802547214636663,2.102925694377315e-10,0.14792243709392255,162.57396783557607,9.893813707510583,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-535,Hyperion Solar,Mono-c-Si,0,535.0,496.3,2.58,,,72.0,13.79,49.45,12.9,41.47,0.009810205999999998,-0.147306605,44.0,2.015642168444481,13.80173379626739,2.992150274816033e-10,0.14313954993829722,168.22300603018573,16.482896622642798,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-535-B {Blk},Hyperion Solar,Mono-c-Si,0,535.0,496.3,2.58,,,72.0,13.79,49.45,12.9,41.47,0.009810205999999998,-0.147306605,44.0,2.015642168444481,13.80173379626739,2.992150274816033e-10,0.14313954993829722,168.22300603018573,16.482896622642798,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-535-b {Wht},Hyperion Solar,Mono-c-Si,0,535.0,496.3,2.58,,,72.0,13.79,49.45,12.9,41.47,0.009810205999999998,-0.147306605,44.0,2.015642168444481,13.80173379626739,2.992150274816033e-10,0.14313954993829722,168.22300603018573,16.482896622642798,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-540,Hyperion Solar,Mono-c-Si,1,540.0,502.1,2.58,,,72.0,13.86,49.6,12.97,41.64,0.0077769846,-0.15242080000000002,43.7,1.9939580263590784,13.872088065258444,2.1353809670115128e-10,0.14371706612330198,164.78390497285702,9.983770827718637,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-540-B,Hyperion Solar,Mono-c-Si,1,540.0,502.1,2.58,,,72.0,13.86,49.6,12.97,41.64,0.0077769846,-0.15242080000000002,43.7,1.9939580263590784,13.872088065258444,2.1353809670115128e-10,0.14371706612330198,164.78390497285702,9.983770827718637,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-540-T,Hyperion Solar,Mono-c-Si,1,540.0,502.1,2.58,,,72.0,13.86,49.6,12.97,41.64,0.0077769846,-0.15242080000000002,43.7,1.9939580263590784,13.872088065258444,2.1353809670115128e-10,0.14371706612330198,164.78390497285702,9.983770827718637,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-540,Hyperion Solar,Mono-c-Si,0,540.0,501.1,2.58,,,72.0,13.86,49.6,12.97,41.64,0.009860003999999999,-0.14775344,44.0,2.022558452500847,13.871288853619573,3.037676217275467e-10,0.13894139929841887,170.58666377057733,16.576592026855625,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-540-B {Blk},Hyperion Solar,Mono-c-Si,0,540.0,501.1,2.58,,,72.0,13.86,49.6,12.97,41.64,0.009860003999999999,-0.14775344,44.0,2.022558452500847,13.871288853619573,3.037676217275467e-10,0.13894139929841887,170.58666377057733,16.576592026855625,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-540-b {Wht},Hyperion Solar,Mono-c-Si,0,540.0,501.1,2.58,,,72.0,13.86,49.6,12.97,41.64,0.009860003999999999,-0.14775344,44.0,2.022558452500847,13.871288853619573,3.037676217275467e-10,0.13894139929841887,170.58666377057733,16.576592026855625,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-545,Hyperion Solar,Mono-c-Si,1,545.0,506.9,2.58,,,72.0,13.93,49.75,13.04,41.8,0.0078162623,-0.15288175,43.7,2.000518535480033,13.94170279390718,2.1610776320107634e-10,0.14044933127869777,167.17881731241212,10.044168136336198,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-545-B,Hyperion Solar,Mono-c-Si,1,545.0,506.9,2.58,,,72.0,13.93,49.75,13.04,41.8,0.0078162623,-0.15288175,43.7,2.000518535480033,13.94170279390718,2.1610776320107634e-10,0.14044933127869777,167.17881731241212,10.044168136336198,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-DH144P8-545-T,Hyperion Solar,Mono-c-Si,1,545.0,506.9,2.58,,,72.0,13.93,49.75,13.04,41.8,0.0078162623,-0.15288175,43.7,2.000518535480033,13.94170279390718,2.1610776320107634e-10,0.14044933127869777,167.17881731241212,10.044168136336198,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Hyperion Solar HY-WH144P8-545,Hyperion Solar,Mono-c-Si,0,545.0,505.9,2.58,,,72.0,13.93,49.75,13.04,41.8,0.009909802,-0.148200275,44.0,2.0292090500118545,13.940915337795554,3.0737936643131734e-10,0.13568192413004718,173.1553626639447,16.639537077042007,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-545-B {Blk},Hyperion Solar,Mono-c-Si,0,545.0,505.9,2.58,,,72.0,13.93,49.75,13.04,41.8,0.009909802,-0.148200275,44.0,2.0292090500118545,13.940915337795554,3.0737936643131734e-10,0.13568192413004718,173.1553626639447,16.639537077042007,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-545-b {Wht},Hyperion Solar,Mono-c-Si,0,545.0,505.9,2.58,,,72.0,13.93,49.75,13.04,41.8,0.009909802,-0.148200275,44.0,2.0292090500118545,13.940915337795554,3.0737936643131734e-10,0.13568192413004718,173.1553626639447,16.639537077042007,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-550,Hyperion Solar,Mono-c-Si,1,550.0,511.6,2.58,,,72.0,14.0,49.9,13.11,41.96,0.007855540000000001,-0.1533427,43.7,2.007079493919573,14.011325250017466,2.1869384856901234e-10,0.13721666816753997,169.6239297924803,10.104242276348012,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-550-B,Hyperion Solar,Mono-c-Si,1,550.0,511.6,2.58,,,72.0,14.0,49.9,13.11,41.96,0.007855540000000001,-0.1533427,43.7,2.007079493919573,14.011325250017466,2.1869384856901234e-10,0.13721666816753997,169.6239297924803,10.104242276348012,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-DH144P8-550-T,Hyperion Solar,Mono-c-Si,1,550.0,511.6,2.58,,,72.0,14.0,49.9,13.11,41.96,0.007855540000000001,-0.1533427,43.7,2.007079493919573,14.011325250017466,2.1869384856901234e-10,0.13721666816753997,169.6239297924803,10.104242276348012,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-550,Hyperion Solar,Mono-c-Si,0,550.0,510.7,2.58,,,72.0,14.0,49.9,13.11,41.96,0.0099596,-0.14864711,44.0,2.035859964330157,14.010549512586921,3.110131960141585e-10,0.13245745644879167,175.78105553967893,16.702131026659583,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-550-B {Blk},Hyperion Solar,Mono-c-Si,0,550.0,510.7,2.58,,,72.0,14.0,49.9,13.11,41.96,0.0099596,-0.14864711,44.0,2.035859964330157,14.010549512586921,3.110131960141585e-10,0.13245745644879167,175.78105553967893,16.702131026659583,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Hyperion Solar HY-WH144P8-550-b {Wht},Hyperion Solar,Mono-c-Si,0,550.0,510.7,2.58,,,72.0,14.0,49.9,13.11,41.96,0.0099596,-0.14864711,44.0,2.035859964330157,14.010549512586921,3.110131960141585e-10,0.13245745644879167,175.78105553967893,16.702131026659583,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M191SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,191.0,172.6,1.4509079999999999,1.476,0.983,54.0,8.0,33.0,7.3,26.3,0.00312,-0.10956,43.6,1.4027107446449496,8.031124486738538,4.653632060433904e-10,0.35824208901847127,92.07981561130697,13.5157482281945,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M194SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,194.0,175.4,1.4509079999999999,1.476,0.983,54.0,8.0,33.1,7.3,26.4,0.00312,-0.10989200000000002,43.6,1.4076114756173121,8.030879931056045,4.70401582624946e-10,0.3560108511716658,92.23100586416844,13.614814108735093,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M197SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,197.0,178.2,1.4509079999999999,1.476,0.983,54.0,8.1,33.3,7.4,26.6,0.003159,-0.11055599999999999,43.6,1.4164763720132931,8.129752400174345,4.797280901980196e-10,0.347265721620784,94.54204076630855,13.677414770748983,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M200SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,200.0,180.9,1.4509079999999999,1.476,0.983,54.0,8.2,33.6,7.5,26.7,0.0031979999999999995,-0.11155200000000001,43.6,1.4238698711498652,8.230651809382543,4.453749117885014e-10,0.36836720426588593,98.54594125406066,12.879435965144003,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M203SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,203.0,183.7,1.4509079999999999,1.476,0.983,54.0,8.3,33.7,7.5,26.9,0.0032370000000000003,-0.11188400000000001,43.6,1.4417732010669457,8.340442796266384,5.552756271990842e-10,0.3454708490121719,70.90034715226706,14.84030295748752,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M206SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,206.0,186.5,1.4509079999999999,1.476,0.983,54.0,8.3,33.8,7.6,26.9,0.0032370000000000003,-0.112216,43.6,1.4327662796725813,8.329528538406398,4.5447096692568525e-10,0.3596709778317981,101.09777186082181,12.949874575049035,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S206SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,206.0,186.2,1.4509079999999999,1.476,0.983,54.0,8.2,33.5,7.7,26.8,0.009889199999999999,-0.1258595,44.2,1.495784419882487,8.202816243556219,1.5326810543361489e-09,0.3159431829334023,919.9277717024942,9.163447066632951,-0.4682,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M209SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,209.0,189.3,1.4509079999999999,1.476,0.983,54.0,8.4,33.8,7.7,27.2,0.0032760000000000003,-0.112216,43.6,1.4414072160618674,8.425695527957046,5.297903588149862e-10,0.30902927312653455,101.02326673773179,14.24711104374537,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S209SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,209.0,189.0,1.4509079999999999,1.476,0.983,54.0,8.2,33.5,7.8,26.9,0.009889199999999999,-0.1258595,44.2,1.5029789674365064,8.2000021715074,1.7131408535621288e-09,0.2641371813602385,999990.6895198725,10.159920351036616,-0.4682,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M212SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,212.0,188.5,1.4509079999999999,1.476,0.983,54.0,8.5,33.9,7.8,27.3,0.010259500000000001,-0.16363529999999998,44.2,1.6793052115585492,8.514995541481273,1.4138757356428872e-08,0.24361111822632436,138.08766126887198,1.6117914935498157,-0.5445,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M212SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,212.0,191.0,1.617035,1.645,0.983,60.0,8.0,36.4,7.2,29.6,0.00304,-0.122668,44.2,1.5769278905395494,8.033053380581949,7.109590969853332e-10,0.29698277826534464,71.87955857350285,15.79034054803105,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S212SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,212.0,191.8,1.4509079999999999,1.476,0.983,54.0,8.3,33.5,7.9,27.0,0.010009800000000001,-0.1258595,44.2,1.5062395319253121,8.300002035179036,1.8197499331419603e-09,0.2445776444127997,999999.8652566127,10.598980849007585,-0.4682,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M215SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,215.0,191.3,1.4509079999999999,1.476,0.983,54.0,8.6,34.1,7.8,27.4,0.0103802,-0.16460070000000002,44.2,1.6993615963676347,8.623465693707372,1.591268068985599e-08,0.2491167593277164,91.2995724539929,2.552250075601994,-0.5445,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M215SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,215.0,193.7,1.617035,1.645,0.983,60.0,8.0,36.5,7.2,29.8,0.00304,-0.123005,44.2,1.5851499850832123,8.03095498080518,7.520462654385257e-10,0.2781393524647905,71.88229255617962,16.319943904881228,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S215SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,215.0,194.6,1.4509079999999999,1.476,0.983,54.0,8.3,33.6,8.0,27.1,0.010009800000000001,-0.1262352,44.2,1.521357704198215,8.30000150679352,2.1254461049634773e-09,0.181076727649657,999999.0724357864,12.02524504920158,-0.4682,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M218SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,218.0,196.5,1.617035,1.645,0.983,60.0,8.0,36.7,7.3,30.0,0.00304,-0.12367900000000003,44.2,1.5820696579685603,8.022510180391338,6.442792481055973e-10,0.2764600098455684,98.25244547992968,14.824087968783944,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S218SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,218.0,197.4,1.4509079999999999,1.476,0.983,54.0,8.4,33.7,8.1,27.2,0.010130400000000001,-0.1266109,44.2,1.5267969871292928,8.400001468479902,2.179601484273804e-09,0.17435406350021035,999999.1499619379,12.147278966762439,-0.4682,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M221SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,221.0,199.3,1.617035,1.645,0.983,60.0,8.1,37.0,7.3,30.2,0.003078,-0.12469000000000001,44.2,1.6052742990039692,8.130692259315005,7.455412910983402e-10,0.2801042747197865,73.92237805676785,16.11632073826107,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S221SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,221.0,200.2,1.4509079999999999,1.476,0.983,54.0,8.5,33.9,8.1,27.3,0.010251000000000001,-0.12736229999999998,44.2,1.5245374806332581,8.500002041439407,1.8721284498274916e-09,0.23955202614809315,999999.669812458,10.640633054984113,-0.4682,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M223MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,223.0,200.6,1.617035,1.645,0.983,60.0,8.0,36.5,7.5,29.9,0.0034960000000000004,-0.140744,43.0,1.637094188666404,8.0043607833375,1.6445969524790553e-09,0.2460096079982492,451.3130873696945,8.023018050608805,-0.5201,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M223MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,223.0,200.6,1.617035,1.645,0.983,60.0,8.0,36.5,7.5,29.9,0.0034960000000000004,-0.140744,43.0,1.637094188666404,8.0043607833375,1.6445969524790553e-09,0.2460096079982492,451.3130873696945,8.023018050608805,-0.5201,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M224SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,224.0,202.0,1.617035,1.645,0.983,60.0,8.1,37.14,7.4,30.2,0.003078,-0.12516180000000002,44.2,1.5948665067360097,8.123961153892441,5.97549778109115e-10,0.3021824470898591,102.15192701512122,14.006221895713095,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SF,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,224.0,203.0,1.4509079999999999,1.476,0.983,54.0,8.5,33.9,8.2,27.4,0.010251000000000001,-0.12736229999999998,44.2,1.5372990745788475,8.500001412317328,2.25165591783117e-09,0.16574118734260468,999999.9750653714,12.339080897582406,-0.4682,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S224SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,224.0,196.9,1.4509079999999999,1.476,0.983,60.0,8.2,37.1,7.4,30.2,0.006395999999999999,-0.16542890000000002,44.1,1.8957127423658189,8.219152103150641,2.4735396752613738e-08,0.211945125137558,90.74477870594185,16.306133260501916,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M225MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,225.0,202.4,1.617035,1.645,0.983,60.0,8.1,36.7,7.6,30.1,0.0035397000000000002,-0.1415152,43.0,1.6464945215073916,8.103932148027353,1.6762965183912703e-09,0.23880296373897195,491.92091247581044,8.07912785350735,-0.5201,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M225MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,225.0,202.4,1.617035,1.645,0.983,60.0,8.1,36.7,7.6,30.1,0.0035397000000000002,-0.1415152,43.0,1.6464945215073916,8.103932148027353,1.6762965183912703e-09,0.23880296373897195,491.92091247581044,8.07912785350735,-0.5201,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M227SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,227.0,204.8,1.617035,1.645,0.983,60.0,8.2,37.2,7.5,30.3,0.0031159999999999994,-0.12536400000000003,44.2,1.5980095660874485,8.222924743239671,6.10671751025022e-10,0.29104654681650677,104.10506579878398,14.089796890897274,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S227SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,227.0,198.8,1.617035,1.645,0.983,60.0,8.2,37.2,7.5,30.4,0.006395999999999999,-0.16587480000000002,44.1,1.8892529346216143,8.212008863445224,2.229673562662012e-08,0.1978812794653138,135.11941390730684,15.250622579005741,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M228MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,228.0,205.7,1.617035,1.645,0.983,60.0,8.1,36.8,7.6,30.1,0.0037989,-0.1184592,46.2,1.502627767460778,8.107513049079754,1.8472221764185836e-10,0.29187725449114227,314.6799599535248,8.415700698525509,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M228MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,228.0,205.2,1.617035,1.645,0.983,60.0,8.1,36.8,7.6,30.1,0.0035397000000000002,-0.1419008,43.0,1.648251260654152,8.104005318784127,1.6160609406816648e-09,0.252304681337161,510.23902303967793,7.756768918420393,-0.5201,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M230MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,230.0,207.6,1.617035,1.645,0.983,60.0,8.1,36.9,7.7,30.1,0.0037989,-0.1187811,46.2,1.4955984796394381,8.115077527222546,1.5638844595544811e-10,0.30564351486424773,999999.9611589687,6.912387883872809,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M230MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,230.0,207.0,1.617035,1.645,0.983,60.0,8.1,36.9,7.7,30.1,0.0035397000000000002,-0.1422864,43.0,1.6433430908965296,8.151039573253998,1.4436563900467926e-09,0.2653879694082323,999999.9786579331,6.695964810206271,-0.5201,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M230SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,230.0,207.6,1.617035,1.645,0.983,60.0,8.2,37.2,7.5,30.5,0.0031159999999999994,-0.12536400000000003,44.2,1.6043420153751546,8.22063782501999,6.68938447510107e-10,0.25938504424077724,103.06112932593753,14.936147828227865,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S230SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,230.0,201.6,1.617035,1.645,0.983,60.0,8.3,37.3,7.5,30.6,0.006474000000000001,-0.16632070000000002,44.1,1.9144499505561872,8.315525131097662,2.733139825588701e-08,0.17220023240093635,92.06136245889707,17.17533499097356,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M233MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,233.0,210.3,1.617035,1.645,0.983,60.0,8.2,37.0,7.8,30.2,0.0038457999999999995,-0.119103,46.2,1.501928425700849,8.200002380152783,1.6404742353381668e-10,0.29018351101367834,999999.9763423621,7.233789985079101,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M233MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,233.0,209.8,1.617035,1.645,0.983,60.0,8.2,37.0,7.8,30.2,0.0035833999999999996,-0.142672,43.0,1.6543694453666664,8.200001898857114,1.5878472629087838e-09,0.2311517860650161,999999.9743556296,7.469493798531325,-0.5201,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M233SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,233.0,202.5,1.617035,1.645,0.983,60.0,8.3,37.5,7.6,29.7,0.009711000000000001,-0.1668375,46.2,1.8743096602738478,8.318135164751435,1.6536156927846015e-08,0.34711054912720757,158.86412887090032,12.097568076986175,-0.5822,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S233MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,233.0,205.9,1.617035,1.645,0.983,60.0,8.2,37.1,7.7,30.5,0.0029027999999999997,-0.13712159999999998,47.0,1.6153200176794402,8.204519304489986,8.606833059084796e-10,0.24100667711829982,437.2920110334973,6.835389448489098,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S233SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,233.0,204.3,1.617035,1.645,0.983,60.0,8.3,37.4,7.6,30.8,0.006474000000000001,-0.16676660000000001,44.1,1.9078897848165484,8.30962559448387,2.46426445317478e-08,0.15893565861225004,137.04808926495326,16.112145620411116,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M235MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,235.0,212.2,1.617035,1.645,0.983,60.0,8.3,37.1,7.8,30.3,0.0038927,-0.1194249,46.2,1.5123456464885225,8.306716220123032,1.820522652452032e-10,0.2941469030007528,363.51092183570705,8.069423196158017,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M235MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,235.0,211.6,1.617035,1.645,0.983,60.0,8.3,37.1,7.8,30.3,0.0036271000000000003,-0.1430576,43.0,1.6586868275280235,8.303194207607062,1.593703599730155e-09,0.2554558881163331,663.7911071433741,7.415136674019497,-0.5201,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M235RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,235.0,211.4,1.63672,1.64,0.998,60.0,8.3,37.1,7.8,30.5,0.003867053,-0.116712519,46.8,1.5175867646467525,8.306367296474873,1.9800286499212468e-10,0.26419063320663744,344.38202339542835,11.353815161575225,-0.433266,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S235MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,235.0,207.8,1.617035,1.645,0.983,60.0,8.3,37.1,7.7,30.5,0.0029382,-0.13712159999999998,47.0,1.6265019749117455,8.311124731852763,1.005475812285914e-09,0.23568721337333262,175.84282557907562,8.127285703051008,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S235MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,235.0,207.8,1.617035,1.645,0.983,60.0,8.3,37.1,7.7,30.5,0.0029382,-0.13712159999999998,47.0,1.6265019749117455,8.311124731852763,1.005475812285914e-09,0.23568721337333262,175.84282557907562,8.127285703051008,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M236SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,236.0,205.2,1.617035,1.645,0.983,60.0,8.3,37.6,7.6,29.9,0.009711000000000001,-0.1672824,46.2,1.8844662445466442,8.317404459943939,1.7456900249086168e-08,0.32849405630304795,156.6557975891313,12.614907907691174,-0.5822,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S236SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,236.0,207.0,1.617035,1.645,0.983,60.0,8.3,37.5,7.6,31.1,0.006474000000000001,-0.16721250000000001,44.1,1.9220211134890388,8.30765357927542,2.6996530971079185e-08,0.12443261119744749,134.94251844709325,17.01755649503119,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,238.0,215.0,1.617035,1.645,0.983,60.0,8.3,37.2,7.9,30.3,0.0038927,-0.11974680000000003,46.2,1.5090216020301823,8.300002442035511,1.63291650496655e-10,0.29414109599816707,999999.8548548167,7.089359667367732,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M238MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,238.0,214.4,1.617035,1.645,0.983,60.0,8.3,37.2,7.9,30.3,0.0036271000000000003,-0.14344320000000002,43.0,1.6620912388723768,8.300001957207725,1.5810264697848864e-09,0.2353813941086087,999999.9503837939,7.326044561644709,-0.5201,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S238MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,238.0,214.6,1.617035,1.645,0.983,60.0,8.3,37.2,7.8,30.6,0.0033366000000000003,-0.1217556,45.9,1.535008417197765,8.306019040454613,2.449307994835318e-10,0.2587617353731421,356.8214357988037,8.926532128533138,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S238MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,238.0,210.5,1.617035,1.645,0.983,60.0,8.3,37.2,7.8,30.6,0.0029382,-0.1374912,47.0,1.6195234997704486,8.304125173131812,8.700782616468467e-10,0.2361915234889314,475.22626471778943,6.821727899057385,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M239SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,239.0,207.9,1.617035,1.645,0.983,60.0,8.4,37.7,7.7,30.0,0.009828000000000002,-0.16772730000000002,46.2,1.889076819333071,8.416644869984621,1.7614479493525956e-08,0.32237972301151996,162.6926991392121,12.58409793046973,-0.5822,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S239SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,239.0,209.7,1.617035,1.645,0.983,60.0,8.4,37.6,7.6,31.3,0.0065520000000000005,-0.1676584,44.1,1.9474901148799333,8.408957430472013,3.299223497765881e-08,0.09894523317433031,92.78794748170222,18.949980877149603,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,240.0,216.8,1.617035,1.645,0.983,60.0,8.3,37.3,8.0,30.5,0.0038927,-0.1200687,46.2,1.5251819036593992,8.300156829554698,1.9850254991533054e-10,0.21537310400905024,11398.373054722353,8.787814085377502,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,240.0,216.3,1.617035,1.645,0.983,60.0,8.3,37.3,8.0,30.5,0.0036271000000000003,-0.1438288,43.0,1.674423893270654,8.354210228322195,1.7677516299123172e-09,0.18845265863853394,999999.4574372998,8.250850904083988,-0.5201,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,240.0,215.7,1.63672,1.64,0.998,60.0,8.4,37.1,7.9,30.6,0.0018563160000000002,-0.1194249,46.4,1.5104134486952454,8.406010040095486,1.784636868485769e-10,0.24882574240735644,347.7741227337796,8.092360836471636,-0.447763,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,240.0,216.0,1.63672,1.64,0.998,60.0,8.4,37.1,7.9,30.6,0.003913644,-0.116712519,46.8,1.5197543243484217,8.405787749920894,2.0761354964385027e-10,0.24632098909244787,357.4958407048655,11.670210897736442,-0.433266,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,240.0,216.0,1.63672,1.64,0.998,60.0,8.3,37.7,7.9,30.5,0.002846238938053098,-0.13195000000000004,44.2,1.6130847085714184,8.300002427052878,5.875151962248974e-10,0.2921683995203933,999999.9349068709,9.291874048266505,-0.49298107255520507,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M240TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,240.0,215.5,1.63672,1.64,0.998,60.0,8.4,37.1,7.9,30.6,0.0035309400000000006,-0.128377872,46.4,1.54995656813223,8.405092963439703,3.3442363916087294e-10,0.23826278625249606,392.9750870632533,5.488055575045722,-0.45206,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S240MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,240.0,216.5,1.617035,1.645,0.983,60.0,8.4,37.3,7.9,30.7,0.0033768,-0.1220829,45.9,1.539012057737133,8.40560276412973,2.476121455245386e-10,0.2538391209867238,380.5708841698388,8.914182836041892,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S240MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,240.0,212.3,1.617035,1.645,0.983,60.0,8.4,37.3,7.9,30.7,0.0029736000000000003,-0.1378608,47.0,1.6237404214427338,8.403739780211183,8.796050500784873e-10,0.23149235336392834,519.9601889601381,6.809671663706312,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M242SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,242.0,210.6,1.617035,1.645,0.983,60.0,8.4,37.8,7.7,30.2,0.009828000000000002,-0.16817220000000002,46.2,1.899202437856192,8.415918499909367,1.8576623007363668e-08,0.3040301671570277,160.4335756441081,13.094468622467918,-0.5822,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S242SG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,242.0,212.4,1.617035,1.645,0.983,60.0,8.4,37.7,7.7,31.5,0.0065520000000000005,-0.16810430000000004,44.1,1.9405453190654867,8.405338310539982,2.970499480825141e-08,0.08706003351201315,136.9920575772188,17.852024981442028,-0.6071,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M243MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,243.0,219.6,1.617035,1.645,0.983,60.0,8.4,37.5,8.0,30.6,0.0039396,-0.1207125,46.2,1.5228984881833398,8.400002377203403,1.6989009064587853e-10,0.28292395974762363,999999.8135565644,7.327932854680203,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M243MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,243.0,219.0,1.617035,1.645,0.983,60.0,8.4,37.5,8.0,30.6,0.0036708000000000005,-0.1446,43.0,1.6775228194794307,8.40000272266615,1.6439485891163933e-09,0.22407119543110438,692172.0928873956,7.562393594329096,-0.5201,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S243MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,243.0,219.2,1.617035,1.645,0.983,60.0,8.4,37.3,7.9,30.8,0.0033768,-0.1220829,45.9,1.5418441053368632,8.405422304833012,2.5879336796646333e-10,0.23899881996900213,370.2466688941179,9.303316886861364,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S243MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,243.0,215.1,1.617035,1.645,0.983,60.0,8.4,37.3,7.9,30.8,0.0029736000000000003,-0.1378608,47.0,1.6268742001335017,8.403640695371612,9.190668033684059e-10,0.21651822632153908,499.5622664000735,7.190606831383887,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,245.0,221.5,1.617035,1.645,0.983,60.0,8.4,37.5,8.1,30.7,0.0039396,-0.1207125,46.2,1.5345287417578177,8.40015240181382,2.0467204022985133e-10,0.2065907694647734,11386.78914651567,8.951172434861704,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,245.0,217.7,1.617035,1.645,0.983,60.0,8.4,38.0,8.0,30.7,0.003627272727272727,-0.13507733333333333,46.3,1.6488359430002995,8.400002396653294,8.227780291742969e-10,0.2849953619188533,999999.8562010725,10.363341233198454,-0.4988,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,245.0,220.3,1.63672,1.64,0.998,60.0,8.5,37.3,8.0,30.7,0.0018784150000000002,-0.1200687,46.4,1.5161706693576953,8.505752755084789,1.7393612865554023e-10,0.2568218095558646,379.46784828626977,7.763621268479922,-0.447763,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,245.0,220.7,1.63672,1.64,0.998,60.0,8.5,37.3,8.0,30.7,0.003960235,-0.11734169700000001,46.8,1.5255476540303334,8.505525855955716,2.0239656175512356e-10,0.25434311366214074,391.2365303178803,11.33148448282665,-0.433266,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,245.0,220.6,1.63672,1.64,0.998,60.0,8.4,38.0,8.0,30.7,0.002880530973451328,-0.133,44.2,1.6253022570915323,8.400002471297952,5.893274899451188e-10,0.2939516783235056,999999.8576561837,9.213491381359733,-0.49298107255520507,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M245TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,245.0,220.1,1.63672,1.64,0.998,60.0,8.5,37.3,8.0,30.7,0.0035729750000000004,-0.129069936,46.4,1.555794338254009,8.504818108195579,3.2591014301411785e-10,0.24638773406981943,434.67187739344007,5.165230116878784,-0.45206,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S245MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,245.0,221.1,1.617035,1.645,0.983,60.0,8.5,37.4,8.0,30.9,0.0034170000000000003,-0.1224102,45.9,1.5458546745635542,8.505037288222798,2.615859384050397e-10,0.2343831220411612,395.5018496313157,9.290857645864785,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S245MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,245.0,216.9,1.617035,1.645,0.983,60.0,8.5,37.4,8.0,30.9,0.0030090000000000004,-0.1382304,47.0,1.631096002389954,8.503287363475446,9.289499015779551e-10,0.21212261610196512,548.4770027908064,7.178101216636682,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S245RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,245.0,218.4,1.63672,1.64,0.998,60.0,8.54,37.5,7.99,30.71,0.003957112068965517,-0.13154761904761905,45.8,1.6410366723292207,8.54686246665224,1.0031430227556802e-09,0.24861187386828507,309.38530059530177,13.508424722511046,-0.495663750475466,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M248MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,248.0,224.2,1.617035,1.645,0.983,60.0,8.5,37.6,8.1,30.7,0.0039865000000000005,-0.12103440000000001,46.2,1.5278000834691823,8.5000023411626,1.7425737215185096e-10,0.27535644176796537,999999.9378675316,7.445071517838767,-0.4321,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M248MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,248.0,220.4,1.617035,1.645,0.983,60.0,8.5,38.0,8.1,30.7,0.0036704545454545453,-0.13507733333333333,46.3,1.6493027150817152,8.500002373270096,8.380212079890946e-10,0.27889173737625816,999999.7812969867,10.421607450603828,-0.4988,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S248MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,248.0,223.9,1.617035,1.645,0.983,60.0,8.6,37.5,8.0,31.1,0.0034571999999999997,-0.1227375,45.9,1.5632527623886874,8.610877446456952,3.203504096590422e-10,0.21309416230321,168.47795329412446,11.032916757657839,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S248MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,248.0,219.6,1.617035,1.645,0.983,60.0,8.6,37.5,8.0,31.1,0.0030443999999999996,-0.1386,47.0,1.6501601322661603,8.608572270050832,1.1364086618882354e-09,0.19027782081066458,190.89338263045562,8.884261865523138,-0.4974,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,250.0,226.1,1.617035,1.645,0.983,60.0,8.6,37.6,8.1,30.9,0.0040333999999999995,-0.12103440000000001,46.2,1.536286404821977,8.605190082423423,2.000559323878821e-10,0.26018731786087657,431.1321160045149,8.57610123516624,-0.4321,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,250.0,222.3,1.617035,1.645,0.983,60.0,8.6,38.2,8.1,30.9,0.003713636363636363,-0.13578826666666668,46.3,1.6552680939289723,8.60254723396178,8.131947884858234e-10,0.30823245862097254,1040.6592111926304,10.061705195387368,-0.4988,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,250.0,224.9,1.63672,1.64,0.998,60.0,8.7,37.4,8.1,30.9,0.0019226129999999999,-0.1203906,46.4,1.5323801451588963,8.711947456748451,2.1349807980575624e-10,0.23313985844723945,169.76976030349493,9.392436126058238,-0.447763,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,250.0,225.3,1.63672,1.64,0.998,60.0,8.7,37.4,8.1,30.9,0.004053417,-0.117656286,46.8,1.5418067741491095,8.711663540983245,2.479335529620528e-10,0.23066594129575135,172.05699420718608,13.000393763639893,-0.433266,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,250.0,225.2,1.63672,1.64,0.998,60.0,8.6,38.2,8.1,30.9,0.0029491150442477877,-0.13370000000000004,44.2,1.6327884210841115,8.603116961474587,5.913718497641237e-10,0.31387904702789815,866.0235244209416,9.052555629191051,-0.49298107255520507,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M250TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,250.0,224.7,1.63672,1.64,0.998,60.0,8.7,37.4,8.1,30.9,0.003657045,-0.129415968,46.4,1.5727398798122305,8.710758127591394,3.9992714114250477e-10,0.22258860829397276,180.00540044884696,6.756390865590419,-0.45206,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S250MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,250.0,225.7,1.617035,1.645,0.983,60.0,8.6,37.5,8.1,31.1,0.0034571999999999997,-0.1227375,45.9,1.5526965091177698,8.604503286456186,2.761996494541464e-10,0.21541605270408737,411.38362667030003,9.665373141170717,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S250MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,250.0,226.3,1.617035,1.645,0.983,60.0,8.7,37.5,8.2,30.5,0.0037285714285714283,-0.11830708661417322,45.5,1.5315586301148922,8.704718718348216,2.0077811554488003e-10,0.299771164082984,552.6944866252355,10.766280657063657,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S250RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,250.0,223.0,1.63672,1.64,0.998,60.0,8.67,37.65,8.11,30.85,0.004017349137931035,-0.13207380952380954,45.8,1.6483295914901464,8.677045219500307,1.0284414619377466e-09,0.24332027658646688,299.43532729597723,13.599645947293247,-0.495663750475466,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S250RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,250.0,222.2,1.63672,1.64,0.998,60.0,8.7,37.5,8.2,30.5,0.003757475083056478,-0.1336741424802111,46.6,1.6176401889532597,8.70252096251118,7.411604343226583e-10,0.2780900512533033,959.7072140448217,8.830765014188064,-0.4911214953271028,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M253MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,253.0,225.0,1.617035,1.645,0.983,60.0,8.7,38.2,8.2,30.9,0.003756818181818181,-0.13578826666666668,46.3,1.654634261708343,8.702029610123445,8.161012831605025e-10,0.3047544336902174,1306.3434151026238,9.987873865774601,-0.4988,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S253MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,253.0,228.5,1.617035,1.645,0.983,60.0,8.7,37.6,8.1,31.3,0.0034974,-0.12306479999999999,45.9,1.5700494452956746,8.709833530465842,3.375672502195523e-10,0.19441199912753257,172.0017557002814,11.3964538288528,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S253MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,253.0,229.1,1.617035,1.645,0.983,60.0,8.8,37.6,8.3,30.5,0.003771428571428572,-0.11862257217847767,45.5,1.5328178375090833,8.804206644367346,1.9434395163993818e-10,0.3086973056450134,645.7728922011484,10.370872450876854,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M255MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,255.0,226.9,1.617035,1.645,0.983,60.0,8.7,38.3,8.2,31.1,0.003756818181818181,-0.13614373333333332,46.3,1.6627135830452884,8.702186171858509,8.59299503036284e-10,0.28832345681756316,1147.4018090782004,10.449369529515613,-0.4988,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M255RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,255.0,230.4,1.63672,1.64,0.998,60.0,8.8,37.6,8.2,31.0,0.004878464818763326,-0.12539947229551454,45.72,1.5860724715916554,8.810552256300785,4.361539211841706e-10,0.2288089361494937,190.81405849998427,11.299698891028141,-0.44687028657616895,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M255RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,255.0,230.4,1.63672,1.64,0.998,60.0,8.8,37.6,8.2,31.0,0.003542372881355933,-0.11944103896103896,46.42,1.5385254969437672,8.811961946112557,2.0930482121802486e-10,0.24105391076531563,177.33523499709798,10.355768488220102,-0.43264567499095186,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M255RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,255.0,229.8,1.63672,1.64,0.998,60.0,8.7,38.3,8.2,31.1,0.002983407079646018,-0.13405,44.2,1.6400991037984416,8.702724666973134,6.24974000776124e-10,0.29395049409900664,938.5996625593041,9.436376955904153,-0.49298107255520507,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M255TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,255.0,229.3,1.63672,1.64,0.998,60.0,8.8,37.6,8.2,31.0,0.0036990800000000004,-0.130108032,46.4,1.578474325555644,8.810771164268504,3.890197446306179e-10,0.23075606822288505,188.5268427656993,6.416617900368557,-0.45206,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,255.0,230.4,1.617035,1.645,0.983,60.0,8.7,37.7,8.2,31.3,0.0034974,-0.1233921,45.9,1.561344013383258,8.704131240678295,2.8120415264168793e-10,0.20932566850282927,440.82001748339843,9.719391990813365,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,255.0,231.0,1.617035,1.645,0.983,60.0,8.8,37.7,8.3,30.8,0.003771428571428572,-0.11893805774278216,45.5,1.5430171234815615,8.804246496967181,2.140390980465972e-10,0.2785847428499858,577.3102483441436,11.234588518616098,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,255.0,228.0,1.63672,1.64,0.998,60.0,8.8,37.8,8.2,31.0,0.0037062634989200867,-0.1359191489361702,44.6,1.6934244078398137,8.808469955337179,1.7489739297221378e-09,0.22757539796654896,236.4433291747235,15.610151441765362,-0.5190663005100039,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,255.0,227.6,1.63672,1.64,0.998,60.0,8.79,37.79,8.23,30.99,0.004072952586206897,-0.13256492063492065,45.8,1.6543889896798032,8.79650858295699,1.0427498577230064e-09,0.23740897512894318,320.6267400315271,13.596996307386288,-0.495663750475466,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,255.0,226.8,1.63672,1.64,0.998,60.0,8.8,37.7,8.3,30.8,0.0038006644518272428,-0.13438707124010557,46.6,1.629921461122974,8.802187318720735,7.899106110720943e-10,0.2568893536642895,1033.5159399097747,9.290870843671394,-0.4911214953271028,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S255TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,255.0,226.7,1.63672,1.64,0.998,60.0,8.79,37.79,8.23,30.99,0.003995454545454544,-0.13350482939632544,45.6,1.6894457243226424,8.79567278778128,1.6770635411455995e-09,0.22869630347642023,354.3657799334026,17.235420339400683,-0.5179553903345724,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S258MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,258.0,233.2,1.617035,1.645,0.983,60.0,8.8,37.7,8.2,31.4,0.0035376,-0.1233921,45.9,1.5739718446210884,8.809447376343497,3.404569754514506e-10,0.19049616984618398,177.44253521164168,11.367231872245165,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S258MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,258.0,233.8,1.617035,1.645,0.983,60.0,8.9,37.7,8.4,30.8,0.003814285714285715,-0.11893805774278216,45.5,1.5424760730631304,8.903801666151226,2.1479654793434708e-10,0.27551231613794697,644.9961759647629,11.162314077742531,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M260RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,260.0,235.0,1.63672,1.64,0.998,60.0,8.9,37.7,8.4,31.1,0.004933901918976546,-0.12573298153034304,45.72,1.5797900070383366,8.903118656645317,3.825720542943244e-10,0.22643168169046257,646.1893162004411,9.978357679548424,-0.44687028657616895,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M260RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,260.0,235.0,1.63672,1.64,0.998,60.0,8.9,37.7,8.4,31.1,0.0035826271186440686,-0.11975870129870131,46.42,1.5326505633199805,8.904145064424695,1.833354333266354e-10,0.23825471746876445,511.5642942715496,9.035538918001556,-0.43264567499095186,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M260TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,260.0,235.9,1.63672,1.64,0.998,60.0,8.9,37.7,8.4,31.1,0.0027812500000000003,-0.11378367875647671,46.2,1.4984503093056678,8.904946615651857,1.0445190384395439e-10,0.2469207359133699,444.26227121818494,9.829862647195991,-0.42119682768565253,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,260.0,235.0,1.617035,1.645,0.983,60.0,8.8,37.8,8.3,31.4,0.0035376,-0.1237194,45.9,1.5653805603061157,8.803795587031646,2.8419386194761165e-10,0.20522462809338832,475.8096709304271,9.709244876834813,-0.4451,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,260.0,235.7,1.617035,1.645,0.983,60.0,8.9,37.8,8.4,31.0,0.003814285714285715,-0.1192535433070866,45.5,1.5498662554010956,8.90380343550344,2.2617045141703253e-10,0.2597389757890584,607.7866587828083,11.62649565640077,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,260.0,233.5,1.63672,1.64,0.998,60.0,8.9,37.9,8.4,31.1,0.0045856992639327025,-0.13314868421052634,44.3,1.6815731373535838,8.901114999181852,1.445805564005748e-09,0.22661268188038444,1808.8433895424514,16.266944183817547,-0.5097222222222223,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,260.0,232.8,1.63672,1.64,0.998,60.0,8.92,37.94,8.35,31.13,0.004689800210304942,-0.12216282722513087,45.8,1.6457034963531318,8.927089807811855,8.55551956050427e-10,0.23637009739711023,297.3877411726077,21.6458337722867,-0.48545861297539156,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,260.0,231.4,1.63672,1.64,0.998,60.0,8.9,37.8,8.4,31.0,0.003843853820598007,-0.13474353562005278,46.6,1.63730623823199,8.901865558121699,8.345023985224983e-10,0.23811037195511092,1135.9519194028287,9.675999170722003,-0.4911214953271028,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S260TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,260.0,231.2,1.63672,1.64,0.998,60.0,8.92,37.94,8.35,31.13,0.004054545454545454,-0.13403475065616793,45.6,1.6969037258515764,8.925842732378962,1.7182885101376135e-09,0.22379858098762193,341.6697038486236,17.328116957677572,-0.5179553903345724,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,263.0,235.6,1.617035,1.645,0.983,60.0,9.0,37.8,8.5,31.0,0.005005246589716685,-0.13657090909090908,46.2,1.6320770044340966,9.001561230532435,7.842005761913005e-10,0.2366864584755932,1364.4243590562373,7.418257416015742,-0.4767,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S263MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,263.0,238.4,1.617035,1.645,0.983,60.0,9.0,37.8,8.5,31.0,0.003857142857142857,-0.1192535433070866,45.5,1.5493329923393588,9.003389963007658,2.2697784037719725e-10,0.2569213250108113,682.099614814369,11.555421694015168,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M265RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,265.0,239.7,1.63672,1.64,0.998,60.0,9.1,37.9,8.5,31.3,0.005044776119402985,-0.1264,45.72,1.5981662396455132,9.10924037884181,4.4849202378149073e-10,0.21613971089873846,212.85615862531404,11.24069417708846,-0.44687028657616895,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M265RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,265.0,239.7,1.63672,1.64,0.998,60.0,9.1,37.9,8.5,31.3,0.0036631355932203393,-0.12039402597402597,46.42,1.5502637438590035,9.110596542505647,2.1519313372993018e-10,0.22804943680841905,195.84218082811802,10.29550877584017,-0.43264567499095186,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M265TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,265.0,240.6,1.63672,1.64,0.998,60.0,9.1,37.9,8.5,31.3,0.00284375,-0.11438730569948187,46.2,1.5154848419843259,9.111642524340441,1.2265123022472684e-10,0.23678545425206868,185.0756452861581,11.102369397514064,-0.42119682768565253,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,237.5,1.617035,1.645,0.983,60.0,9.0,37.9,8.5,31.2,0.005005246589716685,-0.1369322077922078,46.2,1.6400407802297878,9.00165954546835,8.252843949425928e-10,0.2209101066241917,1198.034840359588,7.865061904721706,-0.4767,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,240.3,1.617035,1.645,0.983,60.0,9.0,37.9,8.5,31.2,0.003857142857142857,-0.11956902887139106,45.5,1.5567133045983474,9.003387919779652,2.3885794345977345e-10,0.2413455531431895,641.1339655308834,12.016012800369623,-0.4421,N,2025.7.3,6/23/2025,4.0,bootstrapping +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,238.1,1.63672,1.64,0.998,60.0,9.0,38.1,8.5,31.3,0.0046372239747634065,-0.1338513157894737,44.3,1.6909736581590737,9.00077708409725,1.4733213711082966e-09,0.22038577908841162,2552.46539534458,16.337407901621184,-0.5097222222222223,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,237.4,1.63672,1.64,0.998,60.0,9.05,38.09,8.47,31.27,0.0047581493165089386,-0.1226458115183246,45.8,1.6529079001179052,9.057271663373083,8.762477800627567e-10,0.23150084553509154,288.11610066155083,21.73999134978157,-0.48545861297539156,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265RW,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,236.0,1.63672,1.64,0.998,60.0,9.0,37.9,8.5,31.2,0.0038870431893687704,-0.1351,46.6,1.6446890351695305,9.001571252782215,8.811257485049595e-10,0.21978230957191675,1258.8956988114414,10.058820480140689,-0.4911214953271028,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S265TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,265.0,235.8,1.63672,1.64,0.998,60.0,9.05,38.09,8.47,31.27,0.004113636363636364,-0.1345646719160105,45.6,1.7043580989341065,9.056008419528313,1.7599299911183253e-09,0.21904130075772976,329.92453978075247,17.419659366741815,-0.5179553903345724,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S268MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,268.0,240.2,1.617035,1.645,0.983,60.0,9.1,38.0,8.6,31.2,0.005060860440713536,-0.1372935064935065,46.2,1.6412440056718485,9.101204983267468,7.993965463649551e-10,0.23047541069702931,1740.5468143731914,7.487219186043236,-0.4767,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S268MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,268.0,243.1,1.617035,1.645,0.983,60.0,9.1,38.0,8.6,31.2,0.0039,-0.11988451443569552,45.5,1.5580073326437487,9.102988703270372,2.3136789248775084e-10,0.25060876336873505,763.0534446819482,11.626038761405823,-0.4421,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M270RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,270.0,244.3,1.63672,1.64,0.998,60.0,9.2,38.0,8.6,31.4,0.005100213219616204,-0.1267335092348285,45.72,1.6022216618973637,9.20882008008798,4.527260139432693e-10,0.2121029899325815,221.23923210521087,11.224230473713675,-0.44687028657616895,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M270RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,270.0,244.3,1.63672,1.64,0.998,60.0,9.2,38.0,8.6,31.4,0.003703389830508475,-0.12071168831168831,46.42,1.5541994795657736,9.210158304630692,2.1721468227100884e-10,0.22390651304485576,202.78384205126594,10.278634338822599,-0.43264567499095186,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M270TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,270.0,245.3,1.63672,1.64,0.998,60.0,9.2,38.0,8.6,31.4,0.002875,-0.11468911917098447,46.2,1.5193340522732357,9.21119165968004,1.2379998558160802e-10,0.23256452694153948,191.17751809225012,11.085003172619643,-0.42119682768565253,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S270MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,270.0,242.1,1.617035,1.645,0.983,60.0,9.1,38.1,8.7,31.4,0.005060860440713536,-0.1376548051948052,46.2,1.6546834689040653,9.100001601526898,9.102685573292438e-10,0.1758288214029755,999999.5104563835,8.617925663533995,-0.4767,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S270MG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,270.0,245.0,1.617035,1.645,0.983,60.0,9.1,38.1,8.7,31.4,0.0039,-0.12019999999999999,45.5,1.5665427667387941,9.100001888696156,2.491908778648003e-10,0.20748490299646105,999999.5286131391,12.27672721261293,-0.4421,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S270RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,270.0,242.7,1.63672,1.64,0.998,60.0,9.2,38.2,8.6,31.4,0.004740273396424815,-0.1342026315789474,44.3,1.7057632604156132,9.206856765686945,1.7054670964993001e-09,0.2117906878459351,284.16829787747577,17.561758399904306,-0.5097222222222223,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S270RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,270.0,242.0,1.63672,1.64,0.998,60.0,9.17,38.23,8.59,31.41,0.00482124079915878,-0.12309659685863873,45.8,1.658937511981911,9.176746787233851,8.881749433222049e-10,0.22600697275148862,307.18096528876436,21.740036566535665,-0.48545861297539156,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S270TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,270.0,240.4,1.63672,1.64,0.998,60.0,9.17,38.23,8.59,31.41,0.004168181818181817,-0.1350592650918635,45.6,1.7105731618547924,9.175509343636218,1.7838699268258123e-09,0.2136721595285712,355.6457968165668,17.419661389282535,-0.5179553903345724,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M273MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,273.0,245.4,1.9399485,1.9655,0.987,72.0,8.2,43.9,7.6,36.2,0.0036735999999999995,-0.14855759999999998,45.5,1.8712713478690874,8.212302837310007,5.168173422167835e-10,0.28079430276826867,187.15304925374502,11.974036352034092,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S273MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,273.0,244.9,1.617035,1.645,0.983,60.0,9.2,38.1,8.7,31.6,0.005116474291710389,-0.1376548051948052,46.2,1.6547773880792729,9.20113718281469,9.190500957195862e-10,0.18552901432974409,1500.9627371188817,8.614486840807084,-0.4767,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M275MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,275.0,247.2,1.9399485,1.9655,0.987,72.0,8.2,44.0,7.6,36.3,0.0036735999999999995,-0.148896,45.5,1.8760497004940748,8.212200785051047,5.201336628953613e-10,0.2787139896782749,187.32031896330628,12.032121621134841,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M275RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,275.0,249.0,1.63672,1.64,0.998,60.0,9.3,38.2,8.7,31.5,0.0051556503198294246,-0.12740052770448554,45.72,1.6080727256805825,9.308736822933325,4.410426095948319e-10,0.21988081189103947,234.05439374038875,10.888815671591999,-0.44687028657616895,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M275RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,275.0,249.0,1.63672,1.64,0.998,60.0,9.3,38.2,8.7,31.5,0.003743644067796611,-0.121347012987013,46.42,1.5599340715587546,9.310096754828074,2.115541882256451e-10,0.23155707857667404,213.28447052619512,9.945061377046255,-0.43264567499095186,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M275TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,275.0,249.9,1.63672,1.64,0.998,60.0,9.3,38.2,8.7,31.5,0.0029062500000000004,-0.11529274611398967,46.2,1.5249907910347003,9.311146167422429,1.2056774239841876e-10,0.24012007772115065,200.3483994514811,10.749030640107222,-0.42119682768565253,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S275MG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,275.0,246.7,1.617035,1.645,0.983,60.0,9.2,38.1,8.7,31.7,0.005116474291710389,-0.1376548051948052,46.2,1.6578465247025627,9.201186719195153,9.587421861129734e-10,0.1719728211391659,1333.2151380405926,8.988724019836871,-0.4767,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S275RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,275.0,247.4,1.63672,1.64,0.998,60.0,9.3,38.4,8.7,31.6,0.004791798107255521,-0.13490526315789475,44.3,1.7151214243669282,9.306396800101421,1.7349910960033765e-09,0.20589459919779113,299.3404225491332,17.620125043701986,-0.5097222222222223,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S275RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,275.0,248.6,1.63672,1.64,0.998,60.0,9.3,38.4,8.7,31.6,0.004520165460186144,-0.11598971722365038,46.48,1.5810380083006277,9.309939274934049,2.5867206942253567e-10,0.23792295337899244,222.6202270074102,17.44331185653688,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S275TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,275.0,245.0,1.63672,1.64,0.998,60.0,9.3,38.38,8.71,31.55,0.004227272727272727,-0.13558918635170603,45.6,1.7180296049941728,9.30567316076594,1.8262134236036198e-09,0.20918499813030988,342.9167550693463,17.510396541368216,-0.5179553903345724,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M278MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,278.0,250.0,1.9399485,1.9655,0.987,72.0,8.3,44.2,7.7,36.4,0.0037184,-0.1495728,45.5,1.881613614405942,8.312215793371635,5.080620274566436e-10,0.28679606403196584,194.8631178386321,11.705985146232448,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M280MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,280.0,251.8,1.9399485,1.9655,0.987,72.0,8.3,44.4,7.7,36.5,0.0037184,-0.15024959999999998,45.5,1.888163169860336,8.312567930177535,4.958923030452134e-10,0.29801623946547207,196.81323947122058,11.486706347202384,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S280MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,280.0,249.5,1.9399485,1.9655,0.987,72.0,8.3,44.5,7.7,36.5,0.0039840000000000006,-0.156195,46.5,1.9259021558885079,8.312089295177168,7.473106129383798e-10,0.30157870418153726,207.05124830504633,11.041267294232199,-0.477,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S280RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,280.0,254.2,1.63672,1.64,0.998,60.0,9.4,38.5,8.8,31.7,0.003280159521435693,-0.11272879177377894,46.04,1.5556572417868226,9.410353192537599,1.6493648387284061e-10,0.2408178991870687,218.64640886275185,16.930124927820014,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S280RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,280.0,253.3,1.63672,1.64,0.998,60.0,9.4,38.5,8.8,31.7,0.004568769389865564,-0.1162917737789203,46.48,1.5850351390991795,9.409489349324767,2.6118478615920924e-10,0.23374055196535157,231.5397266421716,17.430732045688252,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S280TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,280.0,251.8,1.63672,1.64,0.998,60.0,9.4,38.5,8.8,31.7,0.005027245206861756,-0.12221744791666667,46.16,1.645084001919657,9.407837327656537,6.351317237636106e-10,0.21943071296372632,263.18270854096903,19.94195694915356,-0.46799016163035834,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M283MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,283.0,254.6,1.9399485,1.9655,0.987,72.0,8.3,44.5,7.8,36.6,0.0037184,-0.150588,45.5,1.8795381208247335,8.30517741249836,4.286386635391166e-10,0.298598067481021,478.68786246259845,10.133523145366672,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S283MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,283.0,253.9,1.9399485,1.9655,0.987,72.0,8.3,44.6,7.8,36.6,0.0028469,-0.14914239999999998,45.9,1.8675618304475117,8.305550664531026,3.4900554900183055e-10,0.31536585422919705,471.5718347647933,9.749218598369145,-0.4649,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M285MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,285.0,256.4,1.9399485,1.9655,0.987,72.0,8.3,44.7,7.8,36.7,0.0037184,-0.1512648,45.5,1.8860764128723937,8.305258139173734,4.1857009882558077e-10,0.3096763606944665,488.82585714147456,9.921809721235366,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S285MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,285.0,255.7,1.9399485,1.9655,0.987,72.0,8.3,44.7,7.8,36.7,0.0028469,-0.14947680000000002,45.9,1.8722729419348294,8.305527711989035,3.513258949632073e-10,0.3133679804183918,470.53007473447786,9.807960286497806,-0.4649,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S285RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,285.0,258.9,1.63672,1.64,0.998,60.0,9.5,38.7,8.9,31.8,0.00331505483549352,-0.11331439588688948,46.04,1.5614075575216992,9.51021373418357,1.6081692750065394e-10,0.24809504099872293,230.75821016718825,16.589417394296046,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S285RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,285.0,258.0,1.63672,1.64,0.998,60.0,9.5,38.7,8.9,31.8,0.004617373319544984,-0.11689588688946015,46.48,1.5908649409194988,9.509335387647688,2.5472352904101093e-10,0.24109010270169082,245.34130345171275,17.089999299930376,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S285TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,285.0,256.5,1.63672,1.64,0.998,60.0,9.5,38.7,8.9,31.8,0.005080726538849647,-0.12285234375,46.16,1.651067856732685,9.507654957391736,6.196679548893371e-10,0.22692864771210333,281.6243791363189,19.59660170891603,-0.46799016163035834,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M288MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,288.0,259.2,1.9399485,1.9655,0.987,72.0,8.3,44.9,7.8,36.8,0.0037184,-0.15194159999999998,45.5,1.8926136165860248,8.305331603687687,4.0880007583898706e-10,0.3207571366510136,499.34035157656535,9.71187085431271,-0.4626,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S288MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,288.0,258.5,1.9399485,1.9655,0.987,72.0,8.3,44.8,7.8,36.9,0.0028469,-0.14981119999999998,45.9,1.879900112158627,8.305364734299594,3.668791858016762e-10,0.29629514609097873,458.41043167167066,10.192774978625902,-0.4649,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S290FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,269.0,1.66,,,60.0,9.59,38.87,9.15,31.7,0.0040278,-0.11039079999999998,44.64,1.4500011340388037,9.590002831468782,2.1864463785999633e-11,0.295238341418406,999999.7805088594,2.1606119113574356,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S290HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,269.0,1.6616,,,60.0,9.59,38.87,9.15,31.7,0.0040278,-0.11039079999999998,44.64,1.4500011340388037,9.590002831468782,2.1864463785999633e-11,0.295238341418406,999999.7805088594,2.1606119113574356,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S290RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,262.0,1.62,,,60.0,9.75,39.6,9.2,31.9,0.0031200000000000004,-0.114048,48.9,1.5221719198835515,9.756952430996064,4.866828360989509e-11,0.3413145756161152,478.65520692639086,7.4657300343861275,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M290MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,290.0,261.0,1.9399485,1.9655,0.987,72.0,8.3,45.1,7.9,37.0,0.0037184,-0.1526184,45.5,1.8969193170102145,8.300002467246907,3.922422686124241e-10,0.29713155516481715,999999.9813626858,9.313000711919816,-0.4626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M290RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,290.0,258.7,1.95608,1.96,0.998,60.0,8.5,44.5,8.2,35.4,0.004537037037037037,-0.1629701986754967,46.1,1.9219595476611993,8.500002772871536,7.481693820090839e-10,0.3259360555500234,999999.9097861282,6.067102272106723,-0.48521262886597943,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M290TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,290.0,259.3,1.63672,1.64,0.998,60.0,8.5,44.5,8.2,35.4,0.003930107526881721,-0.15511147902869757,46.2,1.9262463192056072,8.500002758102903,7.877307386728779e-10,0.3241878099784553,999999.937305142,12.023360711685621,-0.49611057537769204,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S290MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,260.3,1.9399485,1.9655,0.987,72.0,8.3,45.0,7.9,37.0,0.0028469,-0.15048,45.9,1.8769074479617414,8.328986592749825,3.221921238961938e-10,0.30794887316264,999999.9398541399,8.979674386854983,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S290RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,263.5,1.63672,1.64,0.998,60.0,9.7,38.8,9.1,32.0,0.0033848454636091724,-0.11360719794344473,46.04,1.567482667738401,9.70902211584343,1.6979980174979244e-10,0.22862335121693608,245.8011647888037,16.899349687281372,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S290RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,262.6,1.63672,1.64,0.998,60.0,9.7,38.8,9.1,32.0,0.004714581178903826,-0.11719794344473006,46.48,1.597085106634213,9.708189701983683,2.6891507415975373e-10,0.22172166301176519,262.61032896831836,17.401248023924875,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S290TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,290.0,261.1,1.63672,1.64,0.998,60.0,9.7,38.8,9.1,32.0,0.005187689202825428,-0.12316979166666665,46.16,1.6575819888327308,9.706604464248334,6.539634942135966e-10,0.20776947926952238,305.1518407240339,19.912586257573064,-0.46799016163035834,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M293MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,293.0,263.8,1.9399485,1.9655,0.987,72.0,8.3,45.2,7.9,37.1,0.0037184,-0.1529568,45.5,1.9015632536328237,8.30000245246225,3.9439575258632307e-10,0.2953487944931787,999999.9338228118,9.361282776424487,-0.4626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S293MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,293.0,263.1,1.9399485,1.9655,0.987,72.0,8.3,45.0,7.9,37.1,0.0028469,-0.15048,45.9,1.879536403905656,8.326914648701575,3.3309726433083527e-10,0.2932107806219603,999999.9846274717,9.273986288623494,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S295FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,273.8,1.66,,,60.0,9.68,39.05,9.24,31.93,0.0040656,-0.11090199999999997,44.64,1.458642394334816,9.68000273564329,2.2865060894223846e-11,0.2825946390760021,999999.7536549005,2.453556350928772,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S295HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,273.8,1.6616,,,60.0,9.68,39.05,9.24,31.93,0.0040656,-0.11090199999999997,44.64,1.458642394334816,9.68000273564329,2.2865060894223846e-11,0.2825946390760021,999999.7536549005,2.453556350928772,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S295RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,266.7,1.62,,,60.0,9.78,39.8,9.25,32.3,0.0031296,-0.11462399999999998,48.9,1.5341242506466553,9.784741931309812,5.258135649946345e-11,0.311869643336442,643.2158388003992,8.102552456348906,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,295.0,265.7,1.9399485,1.9655,0.987,72.0,8.3,45.4,7.9,37.3,0.0037184,-0.1536336,45.5,1.9108510695924483,8.300002422867495,3.9870613736505414e-10,0.2917832942706898,999999.9842434793,9.457202901927982,-0.4626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,295.0,263.3,1.95608,1.96,0.998,60.0,8.6,44.7,8.3,35.6,0.0045904139433551195,-0.16370264900662254,46.1,1.9320828723577286,8.600002713149431,7.705656602415441e-10,0.3152075472959165,999999.9144996163,6.220142619945134,-0.48521262886597943,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M295TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,295.0,264.0,1.63672,1.64,0.998,60.0,8.6,44.7,8.3,35.6,0.003976344086021505,-0.1558086092715232,46.2,1.9363687133382295,8.600002698386213,8.110517956005134e-10,0.31347470276184264,999994.3599793722,12.181970046536728,-0.49611057537769204,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S295MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,265.0,1.9399485,1.9655,0.987,72.0,8.4,45.1,8.0,37.2,0.0028812,-0.1508144,45.9,1.8877472596525313,8.400002261012553,3.5366058721016876e-10,0.2690682104399174,999999.9318199378,9.723484375202698,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S295RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,268.3,1.63672,1.64,0.998,60.0,9.8,39.0,9.2,32.1,0.003402777777777778,-0.1141928020565553,46.04,1.5710680949111657,9.80891714467489,1.5997337012086322e-10,0.23628780651036804,259.6818350666213,16.243419901817216,-0.43042886317222595,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S295RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,267.3,1.63672,1.64,0.998,60.0,9.8,39.0,9.2,32.1,0.004763185108583248,-0.11780205655526992,46.48,1.6029490127504338,9.808005587627829,2.623748663936504e-10,0.22894592681529496,280.26303772707035,17.067910042882907,-0.4372288313505948,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S295TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,295.0,265.8,1.63672,1.64,0.998,60.0,9.8,39.0,9.2,32.1,0.00524117053481332,-0.1238046875,46.16,1.6636021920523307,9.80639115662055,6.383085163915093e-10,0.2151327107913354,329.8778638959024,19.5747167177707,-0.46799016163035834,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M298MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,298.0,268.4,1.9399485,1.9655,0.987,72.0,8.3,45.5,8.0,37.5,0.0037184,-0.153972,45.5,1.9301747829634013,8.300134538950076,4.800286886618632e-10,0.19653118007733522,12124.492481021527,11.110435507946551,-0.4626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S298MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,298.0,267.7,1.9399485,1.9655,0.987,72.0,8.4,45.3,8.0,37.3,0.0028812,-0.15148319999999998,45.9,1.8945566820386097,8.400002344255658,3.467627564349519e-10,0.27897665236780617,999999.9781780482,9.549717243035412,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S300FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,278.5,1.66,,,60.0,9.77,39.23,9.33,32.15,0.0041034,-0.11141319999999999,44.64,1.4670841677300015,9.770002651009081,2.381268451650918e-11,0.2713292625966584,999999.7163484727,2.713622349795496,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S300HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,278.5,1.6616,,,60.0,9.77,39.23,9.33,32.15,0.0041034,-0.11141319999999999,44.64,1.4670841677300015,9.770002651009081,2.381268451650918e-11,0.2713292625966584,999999.7163484727,2.713622349795496,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S300RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,271.4,1.62,,,60.0,9.83,40.0,9.31,32.6,0.0031456,-0.1152,48.9,1.5442514379968335,9.833605568408608,5.510458452028953e-11,0.2946609714679432,803.3455401323918,8.462091823724371,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M300MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,300.0,269.0,1.9399485,1.9655,0.987,72.0,8.3,45.7,8.0,37.7,0.0029050000000000005,-0.145326,48.0,1.8517504757949093,8.300154881986877,1.5877623536351083e-10,0.22919406984612611,12282.346532158925,8.309733227312577,-0.431,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M300RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,300.0,270.3,1.95608,1.96,0.998,72.0,8.7,44.9,8.4,35.8,0.00499025974025974,-0.1538863436123348,45.49,1.895371388773461,8.700002816093615,4.4811532277830683e-10,0.3235127889590564,999999.2719000315,8.531643520100232,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M300TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,300.0,268.6,1.63672,1.64,0.998,60.0,8.7,44.9,8.4,35.8,0.00402258064516129,-0.1565057395143488,46.2,1.9464863028309387,8.700002638689218,8.347510636540767e-10,0.3030217334743449,999999.9526696559,12.338649938468457,-0.49611057537769204,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S300MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,269.6,1.9399485,1.9655,0.987,72.0,8.4,45.4,8.0,37.4,0.0028812,-0.1518176,45.9,1.8991635506410802,8.400002329520088,3.486215269637004e-10,0.2772233308885228,999999.9792659732,9.59685210446468,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S300RG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,272.9,1.63672,1.64,0.998,60.0,9.9,39.1,9.3,32.3,0.003454636091724826,-0.11448560411311057,46.04,1.5799173704903122,9.908122491593039,1.7440353053472263e-10,0.21929159753292604,267.2809023328239,16.953708630424796,-0.4316040955631399,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S300RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,270.3,1.63672,1.64,0.998,60.0,9.9,39.1,9.3,32.3,0.004366153846153846,-0.12848556962025318,46.59,1.6501587357401475,9.90628604577147,5.012466454445252e-10,0.2033299431135747,320.2278336616182,13.266090694828222,-0.461090031045188,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S300TG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,300.0,270.5,1.63672,1.64,0.998,60.0,9.9,39.1,9.3,32.3,0.005294651866801211,-0.12412213541666667,46.16,1.670747983458734,9.905787121987817,6.716708479961737e-10,0.1987015797088364,339.917865207531,19.968946175749608,-0.46799016163035834,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S303MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,303.0,272.3,1.9399485,1.9655,0.987,72.0,8.4,45.5,8.0,37.5,0.0028812,-0.15215199999999998,45.9,1.903770415901489,8.40000231478483,3.5048117817849307e-10,0.27547001040704355,999999.9803064463,9.643779500955247,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S305FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,305.0,283.3,1.6616,,,60.0,9.86,39.42,9.42,32.37,0.0041412,-0.1119528,44.64,1.4757361318123727,9.860002576220792,2.4715018308311808e-11,0.2612680402529588,999999.6651622022,2.9465801627533104,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S305HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,305.0,283.3,1.6616,,,60.0,9.86,39.42,9.42,32.37,0.0041412,-0.1119528,44.64,1.4757361318123727,9.860002576220792,2.4715018308311808e-11,0.2612680402529588,999999.6651622022,2.9465801627533104,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S305RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,305.0,278.0,1.69,,,60.0,9.9,40.1,9.38,32.8,0.0029898000000000004,-0.1280393,44.9,1.6258665308249096,9.901455077435415,1.9203053000008224e-10,0.2616749175497247,1780.3746800168037,8.05024745949491,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M305RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,305.0,275.0,1.95608,1.96,0.998,72.0,8.8,45.1,8.5,36.0,0.005047619047619048,-0.15457180616740088,45.49,1.9052114479268756,8.800002758071306,4.6121063056792346e-10,0.31324664619540404,999999.2997538551,8.68423295251143,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M305TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,305.0,273.3,1.63672,1.64,0.998,60.0,8.8,45.1,8.5,36.0,0.004068817204301076,-0.1572028697571744,46.2,1.956599246488048,8.800002579158448,8.588291645762813e-10,0.2928194565814679,999999.9535456055,12.493443068699376,-0.49611057537769204,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S305MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,305.0,274.2,1.9399485,1.9655,0.987,72.0,8.4,45.6,8.0,37.6,0.0028812,-0.1524864,45.9,1.908377277709402,8.400002300050037,3.5234168378516647e-10,0.27371669096513745,999999.9813027775,9.690500784980802,-0.4649,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S305RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,305.0,270.4,1.95608,1.96,0.998,72.0,8.8,45.3,8.2,37.0,0.0027062566277836694,-0.16808684210526312,46.2,1.9963972246572184,8.809593074146337,1.2086106530036537e-09,0.30160554114725424,276.67144555191504,8.832228758733713,-0.5131,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S305TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,305.0,271.4,1.95608,1.96,0.998,72.0,8.8,45.3,8.2,37.0,0.004353684210526316,-0.16659671052631578,46.1,2.0031180246371587,8.809434710242273,1.3044656593579338e-09,0.299930828548554,279.7534022118324,10.28010531056937,-0.5007,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S310FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,310.0,288.0,1.6616,,,60.0,9.95,39.58,9.51,32.58,0.0041789999999999996,-0.11240719999999998,44.64,1.4835524970474712,9.950002483279949,2.5774502952577703e-11,0.24956454304756076,999999.6224476228,3.220611373794231,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S310HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,310.0,288.0,1.6616,,,60.0,9.95,39.58,9.51,32.58,0.0041789999999999996,-0.11240719999999998,44.64,1.4835524970474712,9.950002483279949,2.5774502952577703e-11,0.24956454304756076,999999.6224476228,3.220611373794231,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S310RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,310.0,282.7,1.69,,,60.0,9.94,40.3,9.45,33.1,0.00300188,-0.12867789999999998,44.9,1.636858629181025,9.940003203857712,2.017951124840699e-10,0.24489576657079581,759955.4358850793,8.438649177739054,-0.445,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,310.0,279.6,1.95608,1.96,0.998,72.0,8.9,45.3,8.6,36.0,0.005104978354978355,-0.15525726872246692,45.49,1.9099918935142284,8.900002925021985,4.4571934491883473e-10,0.32847232679604177,999998.5146911822,8.285442416508742,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M310TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,310.0,279.6,1.95608,1.96,0.998,60.0,8.9,45.3,8.6,36.0,0.004332275132275133,-0.1416850649350649,46.49,1.846177856690381,8.900267176023869,1.9626912346308156e-10,0.35153482419034776,11710.145427838144,11.232995800056338,-0.44023367285799875,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S310MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,310.0,274.6,1.851829,1.931,0.959,72.0,8.5,45.9,8.2,37.8,0.005370370370370371,-0.17458211920529804,46.4,2.0879097920848446,8.678957251442634,2.460718927782071e-09,0.25013024772999015,999999.9648397856,12.202748793036816,-0.5217,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S310RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,310.0,275.0,1.95608,1.96,0.998,72.0,8.9,45.5,8.3,37.2,0.002737009544008484,-0.16882894736842102,46.2,2.0054653465620085,8.909061163787259,1.2269321889222547e-09,0.29444834128197944,289.21132346137193,8.862534801090819,-0.5131,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S310TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,310.0,276.0,1.95608,1.96,0.998,72.0,8.9,45.5,8.3,37.2,0.004403157894736842,-0.16733223684210527,46.1,2.012220971309394,8.90890557388964,1.3242916775593494e-09,0.29278427902270987,292.60114427108147,10.311456903345789,-0.5007,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S315FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,315.0,292.8,1.6616,,,60.0,10.04,39.74,9.6,32.79,0.0042168,-0.11286159999999999,44.64,1.4913668436071283,10.040002390421462,2.6866973372054903e-11,0.23807905771272106,999999.5721261625,3.4921381327768453,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S315HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,315.0,292.8,1.6616,,,60.0,10.04,39.74,9.6,32.79,0.0042168,-0.11286159999999999,44.64,1.4913668436071283,10.040002390421462,2.6866973372054903e-11,0.23807905771272106,999999.5721261625,3.4921381327768453,-0.365,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S315RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,315.0,287.4,1.69,,,60.0,9.99,40.5,9.51,33.4,0.0030169800000000003,-0.1293165,44.9,1.647261568809401,10.011626651483489,2.102936512597581e-10,0.22803064727991973,999999.9638168693,8.73642528117321,-0.445,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M315RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,315.0,284.3,1.95608,1.96,0.998,72.0,9.0,45.5,8.7,36.2,0.0051623376623376625,-0.15594273127753303,45.49,1.9198224946448417,9.000002867186629,4.5857928438048556e-10,0.31840032247844285,999999.2684005239,8.436746343411297,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M315TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,315.0,284.2,1.95608,1.96,0.998,60.0,9.0,45.5,8.7,36.2,0.004380952380952381,-0.14231060606060605,46.49,1.8556264615842981,9.000262813646794,2.0190984520224766e-10,0.3414022694132289,11691.28927326025,11.386885816264101,-0.44023367285799875,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315MI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,315.0,278.8,1.9399485,1.9655,0.987,72.0,8.53,46.13,8.33,38.03,0.005389324618736383,-0.17545693156732894,46.4,2.098381467057382,8.815391388985281,2.4996475092984144e-09,0.24201713046855633,999999.9616896418,12.211618315308415,-0.5217,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,315.0,279.6,1.95608,1.96,0.998,72.0,9.0,45.7,8.4,37.4,0.002767762460233298,-0.16957105263157893,46.2,2.01454496985998,9.008545132685926,1.2454765056614225e-09,0.28745749155144734,302.75930215673714,8.893628667086203,-0.5131,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S315TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,315.0,280.6,1.95608,1.96,0.998,72.0,9.0,45.7,8.4,37.4,0.004452631578947369,-0.16806776315789473,46.1,2.0213353506597453,9.008392332335413,1.3443570027778698e-09,0.28580384065810477,306.4983036934853,10.343587440594955,-0.5007,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S320FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,320.0,298.9,1.66,,,60.0,10.13,39.92,9.69,33.01,0.0043559,-0.10658640000000001,44.37,1.4674384754101109,10.130002412138813,1.5528118727785682e-11,0.23811161147751703,999998.7320484531,5.251174709287448,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S320HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,320.0,298.9,1.66,,,60.0,10.13,39.92,9.69,33.01,0.0043559,-0.10658640000000001,44.37,1.4674384754101109,10.130002412138813,1.5528118727785682e-11,0.23811161147751703,999998.7320484531,5.251174709287448,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S320RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,320.0,292.1,1.69,,,60.0,10.04,40.6,9.57,33.7,0.00303208,-0.1296358,44.9,1.6590528057824792,10.040001910457766,2.3646482644306323e-10,0.19023324760620638,999999.9761123558,9.739518813611316,-0.445,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M320RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,320.0,288.9,1.95608,1.96,0.998,72.0,9.0,45.7,8.8,36.4,0.0051623376623376625,-0.1566281938325991,45.49,1.9401452926237317,9.000001958608078,5.302263042654785e-10,0.21752027579666736,999999.3074429244,9.717404476108108,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M320TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,320.0,288.9,1.95608,1.96,0.998,60.0,9.0,45.7,8.8,36.4,0.004380952380952381,-0.1429361471861472,46.49,1.874544919053476,9.000155676189905,2.3244448452994484e-10,0.24323841206348387,14062.220427049395,12.657837238917269,-0.44023367285799875,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S320RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,320.0,284.2,1.95608,1.96,0.998,72.0,9.1,45.9,8.5,37.6,0.002798515376458112,-0.1703131578947368,46.2,2.0236356570793124,9.108044643552693,1.2642417929977785e-09,0.28062728676156906,317.442197290661,8.925460159836113,-0.5131,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S320TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,320.0,285.2,1.95608,1.96,0.998,72.0,9.1,45.9,8.5,37.6,0.004502105263157895,-0.16880328947368423,46.1,2.030460725603627,9.107894647990928,1.3646596758745835e-09,0.27898381633962976,321.5791031350537,10.376446980940457,-0.5007,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S320VG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,320.0,290.3,1.69,,,60.0,10.1,40.6,9.63,33.3,0.0047066,-0.1323966,46.79,1.6554586872932946,10.100002330801278,2.2556939258134118e-10,0.23070340699243524,999999.9157873085,6.790276309628516,-0.4328,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S325FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,325.0,303.7,1.66,,,60.0,10.43,40.1,9.93,32.71,0.0044849,-0.10706700000000001,44.37,1.4641920534659896,10.431193635511852,1.3292498939862344e-11,0.2926780896806768,2557.424479442638,3.690510871845417,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S325HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,325.0,303.7,1.66,,,60.0,10.43,40.1,9.93,32.71,0.0044849,-0.10706700000000001,44.37,1.4641920534659896,10.431193635511852,1.3292498939862344e-11,0.2926780896806768,2557.424479442638,3.690510871845417,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S325RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,325.0,296.8,1.69,,,60.0,10.09,40.8,9.62,34.0,0.00304718,-0.13027439999999998,44.9,1.6704817606678013,10.090001759681133,2.4925343870199223e-10,0.17434937307523302,999999.9272475216,10.16066902450229,-0.445,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M325RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,325.0,293.5,1.95608,1.96,0.998,72.0,9.1,45.9,8.8,36.6,0.00521969696969697,-0.1573136563876652,45.49,1.939123324779738,9.100002775992847,4.776128242125812e-10,0.30488693607959244,999999.3167966558,8.696738300338374,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M325TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,325.0,293.5,1.95608,1.96,0.998,60.0,9.1,45.9,8.8,36.6,0.00442962962962963,-0.1435616883116883,46.49,1.8741962993348502,9.100254940778907,2.1027053461346178e-10,0.3279490792349557,11706.037047769067,11.65215056650405,-0.44023367285799875,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S325RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,325.0,288.0,1.95608,1.96,0.998,72.0,9.2,46.1,8.6,37.8,0.00282624,-0.171808707,46.2,2.055254368492819,9.207081169221048,1.6462058495241281e-09,0.2685983087017527,348.9686095861569,10.687803785251127,-0.52415,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S325TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,325.0,294.2,1.95608,1.96,0.998,60.0,9.2,46.1,8.6,37.8,0.0037209302325581393,-0.13820021645021646,46.03,1.8872557241942327,9.21099628795258,2.224884840040302e-10,0.30912369823865754,258.62711473104275,17.111791112602763,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S325VG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,325.0,295.0,1.69,,,60.0,10.15,41.0,9.69,33.6,0.0047299,-0.13370100000000001,46.79,1.6721101416175275,10.150002332753042,2.2782439630484576e-10,0.22975971790152597,999999.7707586493,6.833357700034038,-0.4328,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S330FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,330.0,308.5,1.66,,,60.0,10.51,40.27,10.02,32.91,0.0045192999999999995,-0.10752090000000002,44.37,1.470880819353742,10.51000416387591,1.3533802473860157e-11,0.28460287451973065,718378.9446036828,3.772649156976001,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S330HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,330.0,308.5,1.66,,,60.0,10.51,40.27,10.02,32.91,0.0045192999999999995,-0.10752090000000002,44.37,1.470880819353742,10.51000416387591,1.3533802473860157e-11,0.28460287451973065,718378.9446036828,3.772649156976001,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiD-S330RG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,330.0,301.5,1.69,,,60.0,10.14,41.0,9.68,34.3,0.00306228,-0.130913,44.9,1.6827213505021699,10.140001566658233,2.656584544266976e-10,0.15446239081809482,999999.9583326274,10.68205126466249,-0.445,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M330RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,330.0,298.2,1.95608,1.96,0.998,72.0,9.2,46.1,8.9,36.8,0.005277056277056277,-0.15799911894273128,45.49,1.9489475107474332,9.200002718260084,4.909917823476557e-10,0.29530109981724406,999999.3424770664,8.84360752728947,-0.46119402985074626,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-M330TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Multi-c-Si,0,330.0,298.2,1.95608,1.96,0.998,60.0,9.2,46.1,8.9,36.8,0.004478306878306878,-0.14418722943722945,46.49,1.8836422339479082,9.200251839011933,2.1614705675278702e-10,0.31829167262119157,11627.637424170485,11.80189876921772,-0.44023367285799875,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S330RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,330.0,292.9,1.95608,1.96,0.998,72.0,9.3,46.3,8.7,38.0,0.0028600290000000005,-0.171797539,46.2,2.0573238736285906,9.306766842223706,1.545312102138166e-09,0.26378545862200853,362.5333858230258,10.50943181425258,-0.520738,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S330TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,330.0,298.9,1.95608,1.96,0.998,60.0,9.3,46.3,8.7,38.0,0.0037613751263902936,-0.13879978354978356,46.03,1.8956963203460213,9.310466542209072,2.2581919206920273e-10,0.30237408394507637,268.67318081567475,17.14715584706519,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S330VG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,330.0,299.7,1.69,,,60.0,10.2,41.4,9.74,33.9,0.0047532,-0.1350054,46.79,1.687961540760703,10.200002376896094,2.274157516351405e-10,0.23296001724953885,999999.2472795725,6.775656707583887,-0.4328,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S335FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,335.0,313.3,1.66,,,60.0,10.6,40.44,10.11,33.11,0.0045579999999999996,-0.1079748,44.37,1.4784941511361318,10.600004153902342,1.4009223065402097e-11,0.2763610713413967,705236.8329791877,3.9919998454327286,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S335HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,335.0,313.3,1.66,,,60.0,10.6,40.44,10.11,33.11,0.0045579999999999996,-0.1079748,44.37,1.4784941511361318,10.600004153902342,1.4009223065402097e-11,0.2763610713413967,705236.8329791877,3.9919998454327286,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S335RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,335.0,303.6,1.95608,1.96,0.998,72.0,9.4,46.5,8.8,38.2,0.003247967479674797,-0.15181461864406776,45.59,1.9170962408774102,9.409633542248084,2.7039013150094093e-10,0.2926706871550712,285.5756102460805,9.058435111332583,-0.4480317190597565,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S335TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,335.0,303.5,1.95608,1.96,0.998,60.0,9.4,46.5,8.8,38.2,0.0038018200202224466,-0.13939935064935066,46.03,1.9041453692100574,9.409951207332005,2.2918722866622387e-10,0.2957749464995778,279.3916975157849,17.18316167198065,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S335VG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,335.0,304.4,1.69,,,60.0,10.25,41.8,9.79,34.3,0.0047765,-0.13630979999999998,46.79,1.7061350225113745,10.250002308616805,2.347392970085876e-10,0.22516514542586216,999999.7131458683,7.0063799589957405,-0.4328,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S340FG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,340.0,318.1,1.66,,,60.0,10.69,40.62,10.21,33.31,0.0045967,-0.10845540000000001,44.37,1.4869427132896809,10.690002822313032,1.4622022197448026e-11,0.2640064641215188,999999.7155066212,4.28251807048531,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S340HG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,340.0,318.1,1.66,,,60.0,10.69,40.62,10.21,33.31,0.0045967,-0.10845540000000001,44.37,1.4869427132896809,10.690002822313032,1.4622022197448026e-11,0.2640064641215188,999999.7155066212,4.28251807048531,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S340RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,340.0,308.3,1.95608,1.96,0.998,72.0,9.5,46.7,8.9,38.4,0.003282520325203252,-0.1524675847457627,45.59,1.9256164636876316,9.50913734344422,2.744201549962961e-10,0.2862353382203303,297.595890693333,9.092873337001622,-0.4480317190597565,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S340TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,340.0,308.2,1.95608,1.96,0.998,60.0,9.5,46.7,8.9,38.4,0.0038422649140546004,-0.13999891774891776,46.03,1.9126025630795558,9.509449984286112,2.3259232688403455e-10,0.28932132940492955,290.85263669823826,17.219766147269,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S340VG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,340.0,309.1,1.69,,,60.0,10.3,42.2,9.84,34.6,0.004799800000000001,-0.13761420000000002,46.79,1.7219899186700314,10.3000023524915,2.3430642088338316e-10,0.2283307425489486,999999.639017428,6.94856084172259,-0.4328,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S345RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,345.0,313.0,1.95608,1.96,0.998,72.0,9.6,46.9,9.0,38.6,0.0033170731707317077,-0.15312055084745757,45.59,1.934144766399944,9.60865498283406,2.7849427831681094e-10,0.2799403064147179,310.5063584324157,9.127839757848735,-0.4480317190597565,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S345TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,345.0,312.9,1.95608,1.96,0.998,60.0,9.6,46.9,9.0,38.6,0.0038827098078867543,-0.14059848484848486,46.03,1.9210676088661245,9.608962582919393,2.360342295808764e-10,0.2830084907673455,303.13602212305744,17.25692917140312,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S350XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,326.6,1.8,,,60.0,11.04,40.2,10.48,33.4,0.00525504,-0.1056054,45.6,2.0140779537431475,11.040061527612233,7.13070340386032e-13,3.1751741165966223,981421.0938300953,98.05799610214105,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350KI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,317.1,1.956,,,72.0,9.6,47.1,9.0,38.7,0.0047904,-0.15100260000000001,45.64,1.9787515209978164,9.607937918966377,4.3536066369292874e-10,0.2806514586779788,339.41571381670616,15.024827095304506,-0.455,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,317.6,1.95608,1.96,0.998,72.0,9.6,47.1,9.0,38.7,0.0033170731707317077,-0.1537735169491525,45.59,1.9405578250541797,9.608822950706804,2.722309339470062e-10,0.2895557128486263,315.0573010878049,8.927772821714651,-0.4480317190597565,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350RI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,317.2,1.956,,,72.0,9.6,47.1,9.0,38.7,0.004608,-0.1562307,45.64,1.9744407926669256,9.608035709322003,4.132651173522781e-10,0.28165306508780447,336.48178697699916,10.706823588769835,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S350TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,350.0,317.5,1.95608,1.96,0.998,60.0,9.6,47.1,9.0,38.7,0.0038827098078867543,-0.14119805194805196,46.03,1.9274733692192414,9.609135845333855,2.3079526330810167e-10,0.29262176968445885,307.48870193592205,17.044582981242122,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,328.9,1.984,,,72.0,9.6,46.82,9.1,39.01,0.004032,-0.128755,45.81,1.7400083007077474,9.604622302528583,1.9618611623175567e-11,0.26581165055952405,552.0607674568946,4.624316902547036,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,328.9,1.984,,,72.0,9.6,46.82,9.1,39.01,0.004032,-0.128755,45.81,1.7400083007077474,9.604622302528583,1.9618611623175567e-11,0.26581165055952405,552.0607674568946,4.624316902547036,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355XG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,331.7,1.82169,,,60.0,11.24,39.95,10.69,33.21,0.0054514,-0.10986250000000002,43.8,1.5005420976828125,11.24240216739928,3.0666166177859315e-11,0.1980421656769329,926.6606647506314,6.99538992827871,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S355XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,330.2,1.82169,,,60.0,11.24,39.95,10.69,33.21,0.0057773600000000005,-0.11305849999999999,44.6,1.5195803169292241,11.241952211939779,4.283415482995063e-11,0.1941454428969692,1117.8063629660603,6.757740184784243,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S355XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S355XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,331.3,1.8,,,60.0,11.14,40.4,10.57,33.6,0.005302640000000001,-0.10613079999999998,45.6,1.473281921991184,11.145387633112634,1.362471094732904e-11,0.20981556708502197,433.8352972095964,5.008578423496884,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355KI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,321.7,1.956,,,72.0,9.7,47.3,9.1,38.9,0.0048403,-0.1516438,45.64,1.987458904707969,9.707473815425482,4.4182273272145373e-10,0.274439055366608,356.18477695748754,15.06303710171478,-0.455,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,322.3,1.95608,1.96,0.998,72.0,9.7,47.3,9.1,38.9,0.0033516260162601624,-0.1544264830508474,45.59,1.9490938872865617,9.708343708237996,2.7628030254578306e-10,0.28328973586916567,329.33926184883916,8.963935579788021,-0.4480317190597565,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355RI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,321.9,1.956,,,72.0,9.7,47.3,9.1,38.9,0.0046559999999999995,-0.15689409999999998,45.64,1.9831317986379282,9.707569818443856,4.1941566540865075e-10,0.27543395541307947,352.94238675549406,10.743924477546608,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S355TI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,355.0,322.2,1.95608,1.96,0.998,72.0,9.7,47.3,9.1,38.9,0.003923154701718908,-0.14179761904761906,46.03,1.9359460109097593,9.708651587490559,2.342167660807539e-10,0.286338441282951,321.0373961899104,17.083019052478807,-0.4400936494000585,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,333.7,1.984,,,72.0,9.69,47.01,9.18,39.2,0.0040698,-0.1292775,45.81,1.748279007225648,9.69500271421753,2.0159388185385154e-11,0.2603784075469799,504.33958293467464,4.7784625000705345,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,333.7,1.984,,,72.0,9.69,47.01,9.18,39.2,0.0040698,-0.1292775,45.81,1.748279007225648,9.69500271421753,2.0159388185385154e-11,0.2603784075469799,504.33958293467464,4.7784625000705345,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360XG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,336.5,1.82169,,,60.0,11.26,40.26,10.72,33.58,0.005461100000000001,-0.11071500000000001,43.8,1.5140259940379595,11.261710821276065,3.175884758256642e-11,0.1872435461695822,1232.368616027959,7.280282582342877,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S360XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,335.0,1.82169,,,60.0,11.26,40.26,10.72,33.58,0.00578764,-0.11393579999999999,44.6,1.5332621631787304,11.261298679475525,4.4362771470927344e-11,0.18330862393734962,1589.3492927778195,7.042227322668435,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S360XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S360XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,336.1,1.8,,,60.0,11.24,40.6,10.66,33.8,0.00535024,-0.1066562,45.6,1.4816311464731258,11.245759911271026,1.4009413512411609e-11,0.20532944544121465,400.6837743157577,5.172555015029031,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360KI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,326.4,1.956,,,72.0,9.8,47.4,9.2,39.1,0.0048902,-0.1519644,45.64,1.9943601634632768,9.806857539744687,4.612078731960587e-10,0.25727628926675583,367.6694736289175,15.365610845035626,-0.455,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,327.0,1.95608,1.96,0.998,72.0,9.7,47.4,9.2,39.1,0.0033516260162601624,-0.15475296610169487,45.59,1.9429403425318226,9.700005861940738,2.46440997380302e-10,0.2709361256313553,448383.4626441612,7.919470909158066,-0.4480317190597565,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S360RI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,360.0,326.6,1.956,,,72.0,9.8,47.4,9.2,39.1,0.004704,-0.1572258,45.64,1.9900374365008464,9.806948827138237,4.3795059616248974e-10,0.2582614532132497,364.2287540997855,11.037664392184162,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,338.4,1.984,,,72.0,9.77,47.21,9.27,39.39,0.0041034,-0.1298275,45.81,1.7549399331946522,9.774040912686413,2.0120328574923806e-11,0.2566389574945642,620.494139604135,4.685933416029039,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,338.4,1.984,,,72.0,9.77,47.21,9.27,39.39,0.0041034,-0.1298275,45.81,1.7549399331946522,9.774040912686413,2.0120328574923806e-11,0.2566389574945642,620.494139604135,4.685933416029039,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,341.3,1.82169,,,60.0,11.28,40.59,10.76,33.92,0.0054708,-0.11162250000000001,43.8,1.526486028490102,11.280390672908407,3.190996608514393e-11,0.18169288303712666,5246.066817482161,7.298322100182556,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S365XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,339.8,1.82169,,,60.0,11.28,40.59,10.76,33.92,0.00579792,-0.1148697,44.6,1.5458824079276716,11.28001986127196,4.457486314473677e-11,0.17773615487322847,100943.9767667315,7.0605677744186055,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S365XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S365XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,340.9,1.8,,,60.0,11.33,40.8,10.74,34.0,0.005393080000000001,-0.10718159999999999,45.6,1.4900134809289745,11.336148031356695,1.4396076855716024e-11,0.20109307987581124,370.5876697902402,5.339875345190043,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S365RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,365.0,332.0,1.956,,,72.0,9.9,47.6,9.3,39.3,0.0036135,-0.1537956,45.46,1.9653493909161,9.907229489681745,2.96215324203529e-10,0.2599851383845431,356.0214161364818,10.5200491437551,-0.4472,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,343.2,1.984,,,72.0,9.85,47.4,9.35,39.6,0.004137,-0.13035,45.81,1.7627946016913576,9.85376052911021,2.0539667357675575e-11,0.24930338902025057,653.0033535015153,4.790250191107188,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,343.2,1.984,,,72.0,9.85,47.4,9.35,39.6,0.004137,-0.13035,45.81,1.7627946016913576,9.85376052911021,2.0539667357675575e-11,0.24930338902025057,653.0033535015153,4.790250191107188,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370XG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,346.1,1.82169,,,60.0,11.3,40.91,10.8,34.26,0.0054805,-0.1125025,43.8,1.540408484326284,11.300003234567873,3.304689483818666e-11,0.17494745786439816,611197.2432118843,7.5847958193540475,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S370XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,344.6,1.82169,,,60.0,11.3,40.91,10.8,34.26,0.0058082,-0.11577529999999998,44.6,1.5607414676279112,11.300003158552784,4.6708106350645356e-11,0.1708255580956592,611165.5316364001,7.450265692742096,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S370XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S370XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,345.7,1.8,,,60.0,11.42,41.0,10.82,34.2,0.00543592,-0.107707,45.6,1.498395366915929,11.426518712918089,1.4789209792441286e-11,0.1969197696451449,344.97972458377575,5.505503606241051,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,370.0,335.2,2.04,,,72.0,9.98,47.3,9.51,39.0,0.004850279999999999,-0.1629012,45.62,1.9919105520086802,9.980002323813405,4.856817124904315e-10,0.23273932365445743,999999.9708900538,7.608655562877536,-0.4568,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370GI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,370.0,335.5,2.04,,,72.0,9.98,47.3,9.51,39.0,0.00530936,-0.1592118,45.55,1.994175044277936,9.980002316603725,4.989562416268157e-10,0.23201171359448483,999999.3453583348,10.304934840726297,-0.4551,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S370RI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,370.0,336.7,1.956,,,72.0,9.9,47.8,9.4,39.5,0.0036135,-0.1544418,45.46,1.9634420892201716,9.900145599960247,2.6461994050122296e-10,0.2584553421313117,17573.62342771791,9.478368954778073,-0.4472,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,348.0,1.984,,,72.0,9.93,47.61,9.43,39.81,0.0041706,-0.13092750000000003,45.81,1.7710165379059535,9.933500636602647,2.0845248340129716e-11,0.2442325874723225,692.7967422698536,4.845362020182125,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,348.0,1.984,,,72.0,9.93,47.61,9.43,39.81,0.0041706,-0.13092750000000003,45.81,1.7710165379059535,9.933500636602647,2.0845248340129716e-11,0.2442325874723225,692.7967422698536,4.845362020182125,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,350.9,1.82169,,,60.0,11.32,41.24,10.84,34.59,0.005490200000000001,-0.11341000000000002,43.8,1.555113938604419,11.320003146988393,3.441970771463591e-11,0.17009405183678275,611859.977502454,7.924093549005215,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S375XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,349.3,1.82,,,60.0,11.32,41.24,10.84,34.59,0.005818480000000001,-0.1167092,44.6,1.5756627726273493,11.320003070403786,4.864132008347475e-11,0.16594399106358765,611826.4529514958,7.787511573150187,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S375XG(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,375.0,350.5,1.8,,,60.0,11.51,41.2,10.91,34.4,0.00547876,-0.1082324,45.6,1.5061200464221607,11.51617749277998,1.5024945715303958e-11,0.19287948793638807,359.37604516910204,5.572316050950646,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,375.0,339.9,2.04,,,72.0,10.03,47.6,9.56,39.3,0.00487458,-0.1639344,45.62,2.006067435045713,10.030002267303814,4.969956610900712e-10,0.22594826304962573,999999.9684434978,7.765372063082092,-0.4568,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S375GI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,375.0,340.2,2.04,,,72.0,10.03,47.6,9.56,39.3,0.00533596,-0.16022160000000002,45.55,2.0083411428495612,10.030002260023187,5.105275217352712e-10,0.22522032408079704,999999.9686308989,10.464831424500304,-0.4551,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S380FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,380.0,352.7,1.984,,,72.0,10.01,47.8,9.5,40.02,0.0042042,-0.13145,45.81,1.7797821167666747,10.013878820780047,2.15405565186527e-11,0.23698587946482294,611.5850149086402,5.059080405955061,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S380HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,380.0,352.7,1.984,,,72.0,10.01,47.8,9.5,40.02,0.0042042,-0.13145,45.81,1.7797821167666747,10.013878820780047,2.15405565186527e-11,0.23698587946482294,611.5850149086402,5.059080405955061,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,380.0,344.6,2.04,,,72.0,10.08,47.9,9.61,39.6,0.0048988799999999996,-0.1649676,45.62,2.020225280201271,10.080002210747299,5.084377750500767e-10,0.21921806043945946,999999.4370803302,7.92022531200979,-0.4568,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380GI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,380.0,344.8,2.04,,,72.0,10.08,47.9,9.61,39.6,0.00536256,-0.1612314,45.55,2.022508097841547,10.080002203410931,5.222282330297705e-10,0.21848982604605355,999999.8893873696,10.622816396543149,-0.4551,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,380.0,344.7,2.04,,,72.0,10.08,47.9,9.61,39.6,0.0046368,-0.1624289,45.48,2.018222123106437,10.080002217170048,4.966122781081702e-10,0.2198570811572991,999999.4800011514,9.439210842466188,-0.4589,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380PI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,380.0,344.7,2.04,,,72.0,10.08,47.9,9.61,39.6,0.00504,-0.16487179999999999,45.58,2.0229809117326703,10.080002201911665,5.25126954979962e-10,0.21833899526385878,999999.3954613083,8.249140351353612,-0.4569,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380QI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,380.0,346.3,2.02,,,72.0,10.08,47.9,9.61,39.6,0.00409248,-0.1549565,45.43,1.9642261253092195,10.080002390404276,2.586240683327708e-10,0.2370821713276824,999999.9670356675,8.933907752697445,-0.4403,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S380VI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,380.0,345.2,2.02,,,72.0,10.08,47.9,9.61,39.6,0.00417312,-0.1605129,45.39,2.0006774117267505,10.080002273430015,4.0329935837115e-10,0.22545396323746583,999999.9665443178,8.962928562441263,-0.4552,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S385FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,385.0,357.5,1.984,,,72.0,10.08,48.0,9.58,40.21,0.0042336000000000006,-0.132,45.81,1.7865094979583613,10.083030510434169,2.1492406490841096e-11,0.23380837418698172,777.6868514205856,4.974889014228219,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S385HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,385.0,357.5,1.984,,,72.0,10.08,48.0,9.58,40.21,0.0042336000000000006,-0.132,45.81,1.7865094979583613,10.083030510434169,2.1492406490841096e-11,0.23380837418698172,777.6868514205856,4.974889014228219,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,385.0,349.3,2.04,,,72.0,10.13,48.2,9.67,39.9,0.00492318,-0.1660008,45.62,2.0353941350359173,10.130002102726241,5.261575404228587e-10,0.20748016426277188,999999.9190001237,8.17587917903277,-0.4568,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385GI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,385.0,349.5,2.04,,,72.0,10.13,48.2,9.67,39.9,0.0053891600000000005,-0.16224120000000003,45.55,2.0376834545108493,10.13000209532906,5.403440013616852e-10,0.20674812369525583,999999.9189167152,10.883732128305624,-0.4551,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,385.0,349.4,2.04,,,72.0,10.13,48.2,9.67,39.9,0.0046598,-0.1634462,45.48,2.03373388416385,10.130093844529728,5.159938003037494e-10,0.23488303006239789,25354.646804772998,9.734570066222792,-0.4589,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385PI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,385.0,349.3,2.04,,,72.0,10.13,48.2,9.67,39.9,0.005065000000000001,-0.1659044,45.58,2.038172309902688,10.130002093749521,5.434183471832416e-10,0.20659180563558813,999999.9189218322,8.505510549835478,-0.4569,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385QI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,385.0,351.0,2.02,,,72.0,10.13,48.2,9.67,39.9,0.00411278,-0.155927,45.43,1.9789092549183398,10.130002285346421,2.6764616345716886e-10,0.22554196172565516,999996.9278703384,9.191385018067535,-0.4403,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S385VI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,385.0,349.9,2.02,,,72.0,10.13,48.2,9.67,39.9,0.004193820000000001,-0.16151820000000003,45.39,2.0157748060235785,10.130031165690898,4.178221276155641e-10,0.2135244082049813,69405.08088741683,9.230571995181565,-0.4552,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S390FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,390.0,364.2,1.98,,,72.0,10.48,48.18,9.66,40.37,0.0045064,-0.12864060000000002,44.52,1.8139982869523306,10.501883332837041,2.9319886703737135e-11,0.22157789766380556,106.11438362194517,10.665600970926176,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S390HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,390.0,364.2,1.98,,,72.0,10.48,48.18,9.66,40.37,0.0045064,-0.12864060000000002,44.52,1.8139982869523306,10.501883332837041,2.9319886703737135e-11,0.22157789766380556,106.11438362194517,10.665600970926176,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,390.0,354.0,2.04,,,72.0,10.18,48.5,9.72,40.2,0.00494748,-0.167034,45.62,2.0495562934249185,10.180002045771031,5.379594380766069e-10,0.20086928983596156,999999.9120951996,8.32671668849791,-0.4568,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390GI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,390.0,354.2,2.04,,,72.0,10.18,48.5,9.72,40.2,0.0054157599999999995,-0.163251,45.55,2.0518544719513137,10.180002038334285,5.524084017035033e-10,0.20013703237923816,999999.9119769145,11.03759563196606,-0.4551,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,390.0,354.1,2.04,,,72.0,10.18,48.5,9.72,40.2,0.0046828,-0.1644635,45.48,2.0475060023020992,10.180002052446838,5.253618782731085e-10,0.20152256471638644,999993.769948885,9.849773011561204,-0.4589,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390PI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,390.0,354.0,2.04,,,72.0,10.18,48.5,9.72,40.2,0.005090000000000001,-0.166937,45.58,2.052354623590791,10.180002036715868,5.555996174865836e-10,0.19997767149270815,999999.9119954663,8.656743108447596,-0.4569,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390QI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,390.0,355.7,2.02,,,72.0,10.18,48.5,9.72,40.2,0.00413308,-0.1568975,45.43,1.9926408829547115,10.180002230065698,2.7365898492480043e-10,0.2190039712277543,999994.1510271843,9.343424952478822,-0.4403,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S390VI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,390.0,354.6,2.02,,,72.0,10.18,48.5,9.72,40.2,0.00421452,-0.1625235,45.39,2.029679439649576,10.180002110102246,4.2668353217396716e-10,0.2072025551821936,999999.9127286854,9.371814979610479,-0.4552,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S395FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,369.0,1.98,,,72.0,10.56,48.37,9.74,40.55,0.0045408,-0.1291479,44.52,1.8210374093223074,10.581441774202847,2.951548623613439e-11,0.21841563060895752,107.5689467439508,10.654512002932163,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S395HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,369.0,1.98,,,72.0,10.56,48.37,9.74,40.55,0.0045408,-0.1291479,44.52,1.8210374093223074,10.581441774202847,2.951548623613439e-11,0.21841563060895752,107.5689467439508,10.654512002932163,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,395.0,358.7,2.04,,,72.0,10.23,48.8,9.77,40.5,0.004971779999999999,-0.1680672,45.62,2.063719332930235,10.23000198879126,5.498880704026308e-10,0.19431662083126788,999993.1261128135,8.475789390372146,-0.4568,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395GI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,395.0,358.9,2.04,,,72.0,10.23,48.8,9.77,40.5,0.00544236,-0.1642608,45.55,2.066026271537294,10.230001981315636,5.646006843555055e-10,0.19358417689142626,999992.9480613677,11.189649243628951,-0.4551,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,395.0,358.7,2.04,,,72.0,10.23,48.8,9.77,40.5,0.0047058000000000004,-0.1654808,45.48,2.0616487188829993,10.23000199546094,5.369823860561285e-10,0.19497403201826272,999999.9059786218,10.000388692407984,-0.4589,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395PI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,395.0,358.7,2.04,,,72.0,10.23,48.8,9.77,40.5,0.005115000000000001,-0.1679696,45.58,2.066537796370065,10.230001979616913,5.679113776550223e-10,0.19342176913945086,999999.9058481246,8.806203891912691,-0.4569,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395QI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,360.4,2.02,,,72.0,10.23,48.8,9.77,40.5,0.00415338,-0.157868,45.43,2.00637343577714,10.230002174665247,2.7973705023577165e-10,0.21252371714862534,999999.9078525278,9.493695427872789,-0.4403,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S395VI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,395.0,359.3,2.02,,,72.0,10.23,48.8,9.77,40.5,0.00423522,-0.1635288,45.39,2.0436895339816323,10.230002053670908,4.3613805097449807e-10,0.2006760026218302,999999.9065838251,9.52187357009069,-0.4552,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S400FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,373.8,1.98,,,72.0,10.64,48.55,9.81,40.77,0.0045752,-0.1296285,44.52,1.8298075916043999,10.661053996285682,3.059339222846159e-11,0.20938480169216456,105.81621976042658,10.910559949223902,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S400HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,373.8,1.98,,,72.0,10.64,48.55,9.81,40.77,0.0045752,-0.1296285,44.52,1.8298075916043999,10.661053996285682,3.059339222846159e-11,0.20938480169216456,105.81621976042658,10.910559949223902,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,400.0,363.4,2.04,,,72.0,10.28,49.1,9.82,40.8,0.0047288,-0.1664981,45.48,2.075792324202145,10.280001938491363,5.487254109586008e-10,0.18848284023786702,999992.4654874915,10.149255136612222,-0.4589,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400PI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,400.0,363.4,2.04,,,72.0,10.28,49.1,9.82,40.8,0.0051400000000000005,-0.16900220000000002,45.58,2.0807218118927726,10.280001922452831,5.803529802469814e-10,0.18692326765734327,999999.899939592,8.953923722544971,-0.4569,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400QI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,365.1,2.02,,,72.0,10.28,49.1,9.82,40.8,0.00417368,-0.15883850000000002,45.43,2.0201068954514163,10.280002119242582,2.858800542222112e-10,0.20610037619835606,999999.9014224567,9.642226971368943,-0.4403,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S400VI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,400.0,364.0,2.02,,,72.0,10.28,49.1,9.82,40.8,0.00425592,-0.16453410000000002,45.39,2.057700572188392,10.280001997215459,4.4569300630005845e-10,0.19420663749134429,999992.6102620724,9.67019628358311,-0.4552,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S405FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,378.6,1.98,,,72.0,10.71,48.73,9.89,40.95,0.0046053000000000005,-0.1301091,44.52,1.835783534055856,10.729995388396565,3.049157202025956e-11,0.2057151716588234,110.18588149261802,10.815460227538239,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S405HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,378.6,1.98,,,72.0,10.71,48.73,9.89,40.95,0.0046053000000000005,-0.1301091,44.52,1.835783534055856,10.729995388396565,3.049157202025956e-11,0.2057151716588234,110.18588149261802,10.815460227538239,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,405.0,368.2,2.04,,,72.0,10.33,49.4,9.87,41.1,0.0047518000000000005,-0.1675154,45.48,2.089936801429038,10.330001881416319,5.605903425087998e-10,0.18204817365477188,999991.7260650861,10.296402485647869,-0.4589,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405PI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,405.0,368.1,2.04,,,72.0,10.33,49.4,9.87,41.1,0.005165,-0.1700348,45.58,2.0949066542894528,10.330001865223801,5.929237723734591e-10,0.18048135223371925,999999.892600277,9.099932721685676,-0.4569,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405QI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,369.9,2.02,,,72.0,10.33,49.4,9.87,41.1,0.00419398,-0.159809,45.43,2.033841244648053,10.330002063799276,2.920876889503237e-10,0.19973313967628087,999991.4083112698,9.789049404587276,-0.4403,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S405VI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,405.0,368.7,2.02,,,72.0,10.33,49.4,9.87,41.1,0.00427662,-0.1655394,45.39,2.0717125362707822,10.330001940655233,4.553479129049229e-10,0.18779364669861376,999991.8777687022,9.81681289378006,-0.4552,N,2025.7.3,6/23/2025,2.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S410FI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,410.0,383.4,1.98,,,72.0,10.79,48.91,9.97,41.12,0.004639699999999999,-0.1305897,44.52,1.8424194321997094,10.809600542226658,3.067617845682698e-11,0.2028924230087667,111.69125969649802,10.8004009485304,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S410HI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,410.0,383.4,1.98,,,72.0,10.79,48.91,9.97,41.12,0.004639699999999999,-0.1305897,44.52,1.8424194321997094,10.809600542226658,3.067617845682698e-11,0.2028924230087667,111.69125969649802,10.8004009485304,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,420.0,391.9,2.15,,,72.0,11.04,49.1,10.45,40.2,0.00484656,-0.1272181,45.7,1.7669227313663183,11.048338516596193,9.34306858273053e-12,0.3294376431043958,436.1676156869479,3.3875514450350677,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,420.0,390.9,2.15,,,72.0,11.04,49.1,10.45,40.2,0.00660192,-0.1285929,46.8,1.7862185814478435,11.04777888760494,1.262075364393253e-11,0.3253807295919181,461.78880185160074,4.591309908817196,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S420YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,420.0,392.0,2.15,,,72.0,11.16,49.3,10.27,40.9,0.00639468,-0.12926459999999998,46.3,1.8146015458428546,11.19068060845588,1.6961960668347223e-11,0.26583214025280183,96.69582323491315,7.081325792830044,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,420.0,393.2,2.2,,,78.0,10.22,52.0,9.73,43.2,0.004885160000000001,-0.139204,43.46,1.9349219626064615,10.221709734436635,2.1717814389333224e-11,0.2905642202845013,1736.8583110968862,7.737269748175513,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S420VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,420.0,381.0,2.18,,,78.0,10.22,52.0,9.73,43.2,0.004190200000000001,-0.169936,46.86,2.1230950978295624,10.220003857204953,2.3576048827806136e-10,0.24885302024451994,659450.9588612218,6.904851952237282,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S425XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,396.7,2.15,,,72.0,11.11,49.3,10.52,40.4,0.004877289999999999,-0.1277363,45.7,1.7746190521706322,11.117998847763046,9.479167300714959e-12,0.32473412557861603,451.03948353018706,3.4550207296165842,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S425XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,395.7,2.15,,,72.0,11.11,49.3,10.52,40.4,0.006643779999999999,-0.1291167,46.8,1.7940076659055357,11.117445552358475,1.2805222970125893e-11,0.32068239949774335,478.51137503160794,4.660117830252568,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S425YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,425.0,396.8,2.15,,,72.0,11.23,49.5,10.35,41.1,0.00643479,-0.129789,46.3,1.8213712887282871,11.259265312128942,1.6947224278953602e-11,0.26160276944904426,100.38502561680986,7.013611611209954,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S425PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,425.0,398.0,2.2,,,78.0,10.27,52.3,9.78,43.5,0.00490906,-0.1400071,43.46,1.947004528604473,10.271575739492253,2.2106665433629373e-11,0.28487293169436295,1856.6807281730762,7.8489943184943645,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S425VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,425.0,385.7,2.18,,,78.0,10.27,52.3,9.78,43.5,0.0042107,-0.1709164,46.86,2.136755876683403,10.270003824891603,2.4077997484271513e-10,0.24299940957671406,652554.968181921,7.044147787478684,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S430XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,402.0,2.173572,,,72.0,10.85,49.17,10.36,41.51,0.0052622500000000004,-0.13521750000000002,43.8,1.857860840980441,10.850210415245918,3.477162304292144e-11,0.18236791424594007,9403.750581239066,8.38562720001263,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S430NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,430.0,400.7,2.204872,,,72.0,11.2,48.6,10.65,40.4,0.0058464,-0.12864420000000001,46.18,1.7736195709576112,11.203608812022006,1.4014831304133904e-11,0.25259689697451,783.9381137137947,4.3315520029135905,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S430XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S430YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,430.0,399.5,2.19,,,72.0,11.2,48.6,10.65,40.4,0.005667199999999999,-0.13617720000000003,45.73,1.8180253111844236,11.20268608795852,2.7401280751950135e-11,0.2433949386125851,1014.867514091067,4.048255497691683,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S430NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,402.8,2.15,,,72.0,11.07,49.7,10.42,41.3,0.00530253,-0.1306116,44.8,1.813373584517336,11.081882583747833,1.3605197472569018e-11,0.2640314344374926,245.97579557918377,5.040507409820009,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S430XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,401.5,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00491241,-0.1282545,45.7,1.7822749127684092,11.197622941581903,9.619271457369746e-12,0.3198069719849507,469.4565749366308,3.5168948825623616,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S430XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,400.4,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00669162,-0.12964050000000002,46.8,1.7912674015090457,11.190019968805931,1.115573224285382e-11,0.3177194711483144,178042.36079970284,3.397934512687735,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S430YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,430.0,401.6,2.15,,,72.0,11.3,49.7,10.42,41.3,0.0064749,-0.1303134,46.3,1.8290269730878088,11.328637809209688,1.7137513071302278e-11,0.2573335316792006,101.53950301965845,7.054998354705604,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S430PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,430.0,402.8,2.2,,,78.0,10.32,52.6,9.83,43.8,0.00493296,-0.1408102,43.46,1.9590852698041739,10.321446083818133,2.2497837783271996e-11,0.27924109612678083,1992.808594674297,7.959231303534796,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S430VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,430.0,390.4,2.18,,,78.0,10.32,52.6,9.83,43.8,0.0042312,-0.1718968,46.86,2.150417418462988,10.320003790367567,2.4585206856865773e-10,0.2372062490592085,645928.2311642808,7.18193047324712,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S435XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,406.7,2.173572,,,72.0,10.92,49.38,10.42,41.75,0.0052962,-0.13579500000000003,43.8,1.8678222820793717,10.920602161921494,3.59828087847035e-11,0.1749486777957613,3172.6346266597707,8.63301155996102,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S435NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,435.0,405.4,2.204872,,,72.0,11.28,48.8,10.72,40.6,0.00588816,-0.1291736,46.18,1.7821323295289642,11.284085713182504,1.4370187416705828e-11,0.24818858603407964,685.2089620092718,4.486572628156489,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S435XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S435YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,435.0,404.3,2.19,,,72.0,11.28,48.8,10.72,40.6,0.00570768,-0.1367376,45.73,1.8202240652369313,11.280009835601975,2.5639941656017372e-11,0.2402188702954857,274907.3634086092,3.4159122983871115,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,407.6,2.15,,,72.0,11.14,49.9,10.49,41.5,0.00533606,-0.13113719999999998,44.8,1.821075921143264,11.151523355360654,1.378021274924708e-11,0.259760000935365,251.11838812093012,5.094521114255081,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,406.3,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00494314,-0.12877270000000002,45.7,1.789972206459299,11.267298430122242,9.75734480831969e-12,0.3152333088639414,486.3411758535138,3.5834125788860685,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,405.2,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00673348,-0.13016430000000004,46.8,1.8095453295740247,11.26675794721296,1.318224748292521e-11,0.3111958036334772,518.5102338106456,4.791081117467032,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S435YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,435.0,406.4,2.15,,,72.0,11.37,49.9,10.49,41.5,0.006515009999999999,-0.1308378,46.3,1.836683830740174,11.39802092787088,1.7328812631272668e-11,0.2531212238244035,102.70853037748823,7.096185892704443,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,435.0,407.6,2.2,,,78.0,10.36,52.9,9.87,44.1,0.00495208,-0.1416133,43.46,1.9712091982368412,10.361352276231505,2.2881952642873927e-11,0.27392653549609347,2098.5942061902015,8.07309110049097,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S435VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,435.0,395.1,2.18,,,78.0,10.36,52.9,9.87,44.1,0.0042476,-0.1728772,46.86,2.164030579438038,10.360003749627483,2.5059543448502064e-10,0.23170660163562468,640278.6569928105,7.313433057078353,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S440XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,411.5,2.173572,,,72.0,11.0,49.57,10.48,41.99,0.005335,-0.1363175,43.8,1.8782547753931707,11.001410582505075,3.7864864412515284e-11,0.1653658795142822,1289.555731828956,9.024865430918119,-0.3581,N,2025.7.3,6/23/2025,4.0,bootstrapping +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S440NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,440.0,410.2,2.204872,,,72.0,11.36,49.0,10.79,40.8,0.00592992,-0.12970299999999998,46.18,1.7906468120454178,11.364546684070904,1.4731730898878516e-11,0.24383738356960658,609.2336013054614,4.640564388186096,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S440XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S440YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,440.0,409.1,2.19,,,72.0,11.36,49.0,10.79,40.8,0.0057481599999999996,-0.137298,45.73,1.835545722299805,11.363600735843491,2.880463272260888e-11,0.23464058188946083,740.2693984723514,4.355292070002174,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S440NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,412.4,2.15,,,72.0,11.21,50.1,10.56,41.7,0.00536959,-0.1316628,44.8,1.828778757873188,11.221171592450473,1.395624478277717e-11,0.255545357022907,256.4243374466113,5.148154163217611,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S440XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,411.1,2.15,,,72.0,11.33,49.9,10.74,41.0,0.00497387,-0.1292909,45.7,1.7976698099741357,11.336980980561282,9.89637143342542e-12,0.31071959460617027,504.29205558800237,3.649427556698969,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S440XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,410.0,2.15,,,72.0,11.33,49.9,10.74,41.0,0.0067753399999999995,-0.1306881,46.8,1.8173355126096282,11.336446844873537,1.3370664650131784e-11,0.30668708878346684,538.9868728218673,4.85837221418425,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S440YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,440.0,411.2,2.15,,,72.0,11.44,50.1,10.56,41.7,0.006555119999999999,-0.13136219999999998,46.3,1.8443418349508054,11.467414484979983,1.7521117146255177e-11,0.24896471707605097,103.89239002564727,7.13717366972804,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S440PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,440.0,412.4,2.2,,,78.0,10.41,53.2,9.92,44.4,0.0049759800000000005,-0.1424164,43.46,1.983286281027019,10.411230342454582,2.3277513098755185e-11,0.26840399843414153,2270.982175915192,8.180399827328152,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S440VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,440.0,399.8,2.18,,,78.0,10.41,53.2,9.92,44.4,0.0042681,-0.1738576,46.86,2.1776937610298783,10.410003710897112,2.557668784235525e-10,0.22602466025035273,634141.0918301808,7.448304097179162,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S445XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,416.3,2.173572,,,72.0,11.07,49.75,10.54,42.22,0.005368950000000001,-0.1368125,43.8,1.8874356283911302,11.071706003210728,3.934859242567407e-11,0.15634937125046608,1014.5277504627246,9.311492878789796,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S445NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,445.0,415.0,2.204872,,,72.0,11.44,49.2,10.86,41.0,0.00597168,-0.1302324,46.18,1.7991560127923258,11.444992006744556,1.5097907470607593e-11,0.23954361297106808,548.9533773374214,4.792628652127338,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S445XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S445YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,445.0,413.9,2.19,,,72.0,11.44,49.2,10.86,41.0,0.00578864,-0.13785840000000002,45.73,1.835639702713268,11.440008104073144,2.619266198324467e-11,0.2319581994411014,327443.93842825794,3.4766142069454764,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S445NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,417.2,2.15,,,72.0,11.28,50.3,10.63,41.9,0.00540312,-0.13218839999999998,44.8,1.836482613612758,11.290827063890001,1.4133401975824477e-11,0.25138626351294563,261.90267846217597,5.201484289780118,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S445XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,415.9,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0050046000000000005,-0.1298091,45.7,1.7951160234162518,11.400007192237391,8.632779720938824e-12,0.30815851925527477,488447.83020992915,2.419494898633385,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S445XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,414.8,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0068172,-0.13121190000000002,46.8,1.8251259568583593,11.406142688971055,1.3560366447230991e-11,0.30223709535016086,560.9111817088215,4.925155004544134,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S445YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,445.0,416.0,2.15,,,72.0,11.51,50.3,10.63,41.9,0.00659523,-0.1318866,46.3,1.852000959576997,11.53681830169174,1.7714420924512947e-11,0.24486291219495473,105.09137097284423,7.17796136630687,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S445PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,445.0,417.2,2.2,,,78.0,10.46,53.5,9.97,44.7,0.004999880000000001,-0.1432195,43.46,1.9953616337765676,10.461112571507726,2.3675307584394923e-11,0.26293829791994583,2472.052133841309,8.28630643623944,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S445VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,445.0,404.5,2.18,,,78.0,10.46,53.5,9.97,44.7,0.004288600000000001,-0.174838,46.86,2.191357661623455,10.46000367002644,2.609902974719944e-10,0.22040053899511927,628250.2934746032,7.5817327904882905,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiA-S450XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,421.1,2.173572,,,72.0,11.14,49.93,10.6,42.45,0.0054029,-0.13730750000000003,43.8,1.889065414901733,11.140005162630102,3.6984191587170197e-11,0.14891398145571033,321332.0411975849,8.693771558054447,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S450NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,450.0,419.8,2.204872,,,72.0,11.52,49.4,10.93,41.2,0.00601344,-0.13076179999999998,46.18,1.7969841838686,11.520009160393652,1.325783494709557e-11,0.2372942764143096,298419.95043445873,3.6040100690140706,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S450XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S450YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,450.0,418.6,2.19,,,72.0,11.52,49.4,10.93,41.2,0.00582912,-0.1384188,45.73,1.84335367378993,11.520008773206037,2.647262677155741e-11,0.22790756309998217,299265.75425745465,3.5073354506376067,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S450NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,422.0,2.15,,,72.0,11.34,50.5,10.69,42.1,0.00543186,-0.132714,44.8,1.8442342744935778,11.350521586443012,1.4308111245841457e-11,0.2474947907886425,266.74594866057487,5.260147455309951,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S450XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,420.7,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00503094,-0.1303273,45.7,1.8031391296985968,11.46001282194526,8.794033877456291e-12,0.30396324043616585,271677.3853751143,2.5303995683389298,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S450XI(BK),HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,419.6,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00685308,-0.1317357,46.8,1.8329579778918992,11.465886206252307,1.3747099710482085e-11,0.2981033228364801,580.3847124127503,4.9964478034051245,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S450YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,450.0,420.8,2.15,,,72.0,11.58,50.5,10.69,42.1,0.00663534,-0.132411,46.3,1.8605321991952943,11.606937954377779,1.8117797118567855e-11,0.24070192354556758,103.47215835629524,7.323656523114963,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S450PJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,450.0,422.0,2.2,,,78.0,10.51,53.8,10.02,45.0,0.00502378,-0.1440226,43.46,2.0074353584024998,10.510998900315872,2.407533109147372e-11,0.257528539257832,2709.6048429966886,8.39084626136647,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S450VJ,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,450.0,409.2,2.18,,,78.0,10.51,53.8,10.02,45.0,0.0043091,-0.1758184,46.86,2.205022267556703,10.510003627045226,2.6626547816712335e-10,0.2148333539035452,622598.8915398392,7.713741942347048,-0.434,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,455.0,424.6,2.204872,,,72.0,11.6,49.6,11.0,41.4,0.0060552,-0.1312912,46.18,1.8045042992712832,11.600007575524174,1.339982873294223e-11,0.23328450508339485,357218.4381162309,3.6355084633908232,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S455YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,455.0,423.4,2.19,,,72.0,11.6,49.6,11.0,41.4,0.005869599999999999,-0.13897920000000002,45.73,1.8618220979285522,11.604855100128345,3.099365329859322e-11,0.22192959770729734,530.2431081577184,4.806119732765015,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S455YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,455.0,425.6,2.15,,,72.0,11.65,50.7,10.76,42.3,0.00667545,-0.1329354,46.3,1.8148911902538436,11.650006261064165,8.59137958512872e-12,0.24711310963226832,459807.2802755418,0.7973040080929691,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460NI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,460.0,429.4,2.204872,,,72.0,11.67,49.8,11.06,41.6,0.00609174,-0.13182059999999998,46.18,1.8119950337359891,11.670006808861357,1.3524640770911125e-11,0.22953156131228208,393406.6492862048,3.662985431955832,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S460YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,460.0,428.2,2.19,,,72.0,11.67,49.8,11.06,41.6,0.0059050199999999995,-0.1395396,45.73,1.8587443695151087,11.670006538318638,2.6997709953783426e-11,0.22016074964191015,392961.5160338726,3.5635598368031367,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S465XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S465YI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,465.0,433.0,2.19,,,72.0,11.75,50.0,11.13,41.8,0.0059455,-0.1401,45.73,1.866461336782094,11.75000615562789,2.7281357218389692e-11,0.21625928509074893,412805.86231370433,3.5939336907421433,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiG-S470XI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S520BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,520.0,488.2,2.57,,,72.0,13.53,49.0,12.79,40.7,0.00669735,-0.127988,44.1,1.754059711894689,13.541357353317707,9.852019377188622e-12,0.22007368855233728,262.1734953839001,1.2364302437109111,-0.3332,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S525BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,525.0,493.0,2.57,,,72.0,13.59,49.2,12.85,40.9,0.00672705,-0.1285104,44.1,1.7990425213723342,13.599898289975023,1.782509665186111e-11,0.21051722552251426,289.0326635572045,6.207005964260254,-0.3332,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S530BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,530.0,497.8,2.57,,,72.0,13.65,49.4,12.91,41.1,0.006756750000000001,-0.1290328,44.1,1.806881359094279,13.659613668435641,1.8050740095819512e-11,0.20746073382624894,294.56383445477763,6.276855361865615,-0.3332,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S535BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,535.0,502.6,2.57,,,72.0,13.71,49.6,12.96,41.3,0.00678645,-0.1295552,44.1,1.8016345182913098,13.710010023714512,1.4988443979701642e-11,0.20815447864917483,284706.0869063622,2.4329674287914345,-0.3332,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S540BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,540.0,507.4,2.57,,,72.0,13.77,49.8,13.02,41.5,0.00681615,-0.1300776,44.1,1.8232225525060577,13.77978082083456,1.8673781370208932e-11,0.2013778377296329,283.51126058928537,6.49649128248458,-0.3332,N,2025.7.3,6/23/2025,4.0,first_pass +HYUNDAI ENERGY SOLUTIONS CO LTD HiN-S545BI,HYUNDAI ENERGY SOLUTIONS CO LTD,Mono-c-Si,1,545.0,512.3,2.57,,,72.0,13.83,50.0,13.07,41.7,0.0068458500000000005,-0.1306,44.1,1.8317272286159374,13.840209701635514,1.907581373722181e-11,0.1983456362678382,268.67780069579766,6.645932927258651,-0.3332,N,2025.7.3,6/23/2025,4.0,first_pass +Illuminate USA LLC IL5-72HBD-540M,Illuminate USA LLC,Mono-c-Si,1,540.0,497.4,2.51,,,72.0,13.85,49.5,12.97,41.7,0.0062325,-0.13167,48.7,1.867820472846247,13.864330644921644,4.185710779633652e-11,0.15201024154828538,146.9118710139717,11.68305587544871,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Illuminate USA LLC IL5-72HBD-545M,Illuminate USA LLC,Mono-c-Si,1,545.0,502.1,2.51,,,72.0,13.92,49.7,13.04,41.8,0.006264,-0.13220200000000001,48.7,1.8734656181507137,13.934658261815782,4.0974859291245404e-11,0.1579498903351004,149.99476174422543,11.443265624731115,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +Illuminate USA LLC IL5-72HBD-550M,Illuminate USA LLC,Mono-c-Si,1,550.0,506.9,2.51,,,72.0,13.99,49.8,13.12,42.0,0.0062955,-0.132468,48.7,1.878868889033862,14.00314032992415,4.218569811811158e-11,0.14746252152866982,156.9976325806495,11.656854595020873,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Illuminate USA LLC IL5-72HBD-555M,Illuminate USA LLC,Mono-c-Si,1,555.0,511.7,2.51,,,72.0,14.05,50.0,13.19,42.1,0.0063225,-0.133,48.7,1.8838525199251592,14.062915769510028,4.0923025364492905e-11,0.15356311624018076,167.04864532765063,11.339033826536376,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Illuminate USA LLC IL5-72HBD-560M,Illuminate USA LLC,Mono-c-Si,1,560.0,516.4,2.51,,,72.0,14.1,50.1,13.26,42.3,0.006344999999999999,-0.133266,48.7,1.8886324887646257,14.111053365306429,4.173192331795132e-11,0.1435231150312044,183.0823356401234,11.476603746994694,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +Illuminate USA LLC IL5-72HBD-565M,Illuminate USA LLC,Mono-c-Si,1,565.0,521.2,2.51,,,72.0,14.16,50.3,13.33,42.4,0.006372,-0.133798,48.7,1.8936358579839674,14.170766976102264,4.0501362026051465e-11,0.14957310723821615,196.70845198236555,11.163770095544661,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-385/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,385.0,361.1,1.94,,,108.0,13.25,36.62,12.55,30.7,0.0008321,-0.09022435599999999,42.6,1.3003504404212014,13.258847411838882,7.7001922812965e-12,0.14498553382849633,217.1322375249264,6.010475539121843,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-390/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,390.0,366.0,1.94,,,108.0,13.34,36.81,12.62,30.91,0.000837752,-0.090692478,42.6,1.3380941368307702,13.348658735201681,1.4876794360401603e-11,0.13487947268879805,207.80080839298788,11.7530774252331,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-395/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,395.0,370.8,1.94,,,108.0,13.43,37.0,12.7,31.09,0.000843404,-0.0911606,42.6,1.3456984136013685,13.438948858846826,1.5184125931357477e-11,0.1327940698243891,199.29070250346695,11.879328306915621,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-400/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,400.0,375.6,1.94,,,108.0,13.54,37.2,12.8,31.26,0.000850312,-0.09165336,42.6,1.3532183136865694,13.549260367027998,1.5379407426251898e-11,0.1322287198074076,193.33757172078708,11.92274108000987,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-405/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,405.0,380.4,1.94,,,108.0,13.66,37.4,12.89,31.43,0.000857848,-0.09214612,42.6,1.3617277503667744,13.670768442469615,1.587317849045204e-11,0.1314559895863363,166.75473971514486,12.13822002411545,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-410/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,410.0,385.2,1.94,,,108.0,13.77,37.6,12.98,31.6,0.0008647559999999999,-0.09263887999999999,42.6,1.3208593493943728,13.783645215332129,5.862653703326709e-12,0.13937572340244492,140.65030615045686,3.391576791427784,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD108-415/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,415.0,390.0,1.94,,,108.0,13.87,37.8,13.06,31.77,0.0008710359999999999,-0.09313164,42.6,1.377812918163872,13.882626974440708,1.6571324235589526e-11,0.1303383913616501,143.16917351136445,12.401240197574092,-0.36398,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-430/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,430.0,402.8,2.14,,,60.0,13.58,40.5,12.73,33.8,0.0048888,-0.10449000000000001,43.1,1.5200000755888992,13.595912894604048,3.563718783832429e-11,0.15575796475162626,132.9232192396445,13.97128021458181,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-435/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,435.0,407.6,2.14,,,60.0,13.65,40.7,12.8,34.0,0.004914,-0.10500600000000002,43.1,1.4593267216546895,13.668344751560957,1.0297931497318658e-11,0.1647705741428047,122.60282371280627,3.0258048178318053,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-440/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,440.0,412.4,2.14,,,60.0,13.72,40.9,12.86,34.2,0.0049392,-0.10552199999999999,43.1,1.5366064622561426,13.735644548749931,3.7002567122343906e-11,0.14975763647651988,131.33492096896083,14.224454297322703,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-445/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,445.0,417.2,2.14,,,60.0,13.79,41.1,12.93,34.4,0.004964399999999999,-0.10603800000000001,43.1,1.544613055021668,13.805189355590834,3.752001648337993e-11,0.14684015062822697,133.31215261898296,14.30443070767042,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-450/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,450.0,422.0,2.14,,,60.0,13.86,41.3,13.0,34.6,0.004989599999999999,-0.106554,43.1,1.5526189742392016,13.874743691563626,3.803983516294257e-11,0.14395465807523422,135.326459166957,14.383524577857662,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-455/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,455.0,426.8,2.14,,,60.0,13.93,41.5,13.06,34.9,0.0050148,-0.10707000000000001,43.1,1.5635106109031605,13.94410670876233,4.0454819371610215e-11,0.13221210255288138,130.55593850911123,14.910200054114512,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-460/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,460.0,431.6,2.14,,,60.0,14.0,41.7,13.13,35.1,0.00504,-0.10758600000000001,43.1,1.5715129523116762,14.013677901555967,4.099292579073564e-11,0.12943580298206495,132.48386350916914,14.98508454982021,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDD120-465/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,465.0,436.5,2.14,,,60.0,14.07,41.9,13.19,35.3,0.005065200000000001,-0.108102,43.1,1.5801134620319335,14.083794219712548,4.1915435300720746e-11,0.1265994563829068,129.13049086883038,15.14785266372594,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-520/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,520.0,488.4,2.56,,,144.0,13.63,48.88,12.66,41.09,0.00448427,-0.12874992000000002,42.9,1.8272107001898292,13.651471898722908,3.1771288813445955e-11,0.16331576164075068,103.67009772774047,10.648893659129211,-0.3543,N,2025.7.3,6/23/2025,2.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-525/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,525.0,493.2,2.56,,,144.0,13.69,49.03,12.74,41.24,0.004504009999999999,-0.12914502000000003,42.9,1.8315917312721641,13.70993072091415,3.141371257880653e-11,0.16120239198500955,110.72658956528144,10.500154873851733,-0.3543,N,2025.7.3,6/23/2025,2.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-530/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,530.0,498.0,2.56,,,144.0,13.75,49.18,12.81,41.39,0.00452375,-0.12954012,42.9,1.8367110395983772,13.768982527759958,3.1368794596338446e-11,0.1590027069697644,115.17366168433189,10.443556695878632,-0.3543,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-535/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,535.0,502.8,2.56,,,144.0,13.81,49.33,12.88,41.54,0.00454349,-0.12993522000000002,42.9,1.8418350364216602,13.828054836049352,3.13263059891867e-11,0.15682565810321208,119.95469472728726,10.387861826259224,-0.3543,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-540/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,540.0,507.6,2.56,,,144.0,13.87,49.48,12.96,41.69,0.00456323,-0.13033032,42.9,1.8462455829391748,13.886602851026906,3.099008422912347e-11,0.1547796009008037,129.30267638370668,10.244794954471143,-0.3543,N,2025.7.3,6/23/2025,2.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-545/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,545.0,512.5,2.56,,,144.0,13.93,49.63,13.03,41.84,0.0045829700000000004,-0.13072542,42.9,1.8513818935282798,13.945722260691396,3.0954704205516456e-11,0.1526468778781123,135.2458823161093,10.191499997888986,-0.3543,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-550/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,550.0,517.3,2.56,,,144.0,13.99,49.78,13.1,41.99,0.0046027099999999994,-0.13112052000000002,42.9,1.856522553356625,14.004861252731743,3.092149649665945e-11,0.1505357890680177,141.7105096264485,10.139040096401894,-0.3543,N,2025.7.3,6/23/2025,4.0,first_pass +IMPERIAL STAR SOLAR(CAMBODIA) CO LTD ISM7-SHDB144-555/M,IMPERIAL STAR SOLAR(CAMBODIA) CO LTD,Mono-c-Si,0,555.0,522.1,2.56,,,144.0,14.05,49.93,13.18,42.14,0.00462245,-0.13151562000000003,42.9,1.8609609447811972,14.063494854183247,3.0604789787402125e-11,0.14855408042871104,154.66523813364822,10.00130931104349,-0.3543,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-165,JA Solar,Mono-c-Si,0,165.0,148.0,1.2766400000000002,1.58,0.808,72.0,5.03,44.79,4.56,36.2,0.0025150000000000003,-0.143328,46.1,1.8890357437412753,5.050501803544424,2.406932283407003e-10,0.6582830665819812,161.50598382466245,15.864257013256932,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-170,JA Solar,Mono-c-Si,0,170.0,152.6,1.2766400000000002,1.58,0.808,72.0,5.11,44.96,4.67,36.4,0.0025550000000000004,-0.143872,46.1,1.8895656232397418,5.126718572987996,2.271276541142687e-10,0.6362228557927353,194.46031655818229,15.147234655896499,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-175,JA Solar,Mono-c-Si,0,175.0,157.2,1.2766400000000002,1.58,0.808,72.0,5.2,45.13,4.78,36.6,0.0026000000000000003,-0.14441600000000002,46.1,1.8924965619928387,5.2140078590221925,2.206997354026591e-10,0.6132931646243435,227.6668169530257,14.697943549011201,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-180/SI,JA Solar,Mono-c-Si,0,180.0,160.2,1.2766400000000002,1.58,0.808,72.0,5.44,44.88,4.94,36.42,0.0033456000000000002,-0.15824688000000003,47.6,1.9380084509834288,5.459103913500374,4.536327449664268e-10,0.5569970777540695,158.60961548897336,9.763089621599631,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)-72-180/SI,JA Solar,Mono-c-Si,0,180.0,160.2,1.2766400000000002,1.58,0.808,72.0,5.44,44.88,4.94,36.42,0.0033456000000000002,-0.15824688000000003,47.6,1.9380084509834288,5.459103913500374,4.536327449664268e-10,0.5569970777540695,158.60961548897336,9.763089621599631,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-180,JA Solar,Mono-c-Si,0,180.0,161.8,1.2766400000000002,1.58,0.808,72.0,5.28,45.3,4.89,36.8,0.0026400000000000004,-0.14495999999999998,46.1,1.8937330768191782,5.29054559637945,2.099058005018526e-10,0.592705204723869,296.75739842464685,14.066370904651817,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-185/SI,JA Solar,Mono-c-Si,0,185.0,164.8,1.2766400000000002,1.58,0.808,72.0,5.52,45.18,5.06,36.54,0.0033948,-0.15930468,47.6,1.9364416321630589,5.535800962425234,3.9150163367663074e-10,0.5841748262461235,204.07904889436216,8.299605801602828,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)-72-185/SI,JA Solar,Mono-c-Si,0,185.0,164.8,1.2766400000000002,1.58,0.808,72.0,5.52,45.18,5.06,36.54,0.0033948,-0.15930468,47.6,1.9364416321630589,5.535800962425234,3.9150163367663074e-10,0.5841748262461235,204.07904889436216,8.299605801602828,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-185,JA Solar,Mono-c-Si,0,185.0,166.4,1.2766400000000002,1.58,0.808,72.0,5.37,45.47,5.0,37.0,0.0026850000000000003,-0.145504,46.1,1.8971987411757725,5.378104981799713,2.0517337118777278e-10,0.5713513898253301,378.5520255163098,13.681629180164766,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-190/SI,JA Solar,Mono-c-Si,0,190.0,169.4,1.2766400000000002,1.58,0.808,72.0,5.58,45.38,5.18,36.66,0.0034317,-0.16000988000000002,47.6,1.9300140775253247,5.589812498266884,3.352225389644719e-10,0.592487777926015,336.92564566450886,6.811046801912818,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)-72-190/SI,JA Solar,Mono-c-Si,0,190.0,169.4,1.2766400000000002,1.58,0.808,72.0,5.58,45.38,5.18,36.66,0.0034317,-0.16000988000000002,47.6,1.9300140775253247,5.589812498266884,3.352225389644719e-10,0.592487777926015,336.92564566450886,6.811046801912818,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-190,JA Solar,Mono-c-Si,0,190.0,171.0,1.2766400000000002,1.58,0.808,72.0,5.45,45.64,5.11,37.2,0.002725,-0.146048,46.1,1.8990293149630089,5.454947313410024,1.9644092123906342e-10,0.5521264052696468,608.2269552365277,13.121795919894259,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-195/SI,JA Solar,Mono-c-Si,0,195.0,173.9,1.2766400000000002,1.58,0.808,72.0,5.63,45.5,5.28,36.96,0.00346245,-0.16043300000000002,47.6,1.9306550055024831,5.634482413538881,3.240581367171505e-10,0.5447607438002584,684.2304542118377,6.409283364512574,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)-72-195/SI,JA Solar,Mono-c-Si,0,195.0,173.9,1.2766400000000002,1.58,0.808,72.0,5.63,45.5,5.28,36.96,0.00346245,-0.16043300000000002,47.6,1.9306550055024831,5.634482413538881,3.240581367171505e-10,0.5447607438002584,684.2304542118377,6.409283364512574,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5-72-195,JA Solar,Mono-c-Si,0,195.0,175.6,1.2766400000000002,1.58,0.808,72.0,5.54,45.81,5.21,37.4,0.0027700000000000003,-0.146592,46.1,1.9048608603822825,5.543621419348749,1.9724764872380152e-10,0.5318526120713067,813.6213469389172,12.998582984757837,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-200/SI,JA Solar,Mono-c-Si,0,200.0,178.5,1.2766400000000002,1.58,0.808,72.0,5.66,45.62,5.37,37.26,0.0034809000000000003,-0.16085612000000002,47.6,1.9315064662965142,5.67001003023278,3.1335415138862427e-10,0.49959204294253967,999999.9846771725,6.028512151073175,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM5(L)-72-200/SI,JA Solar,Mono-c-Si,0,200.0,178.5,1.2766400000000002,1.58,0.808,72.0,5.66,45.62,5.37,37.26,0.0034809000000000003,-0.16085612000000002,47.6,1.9315064662965142,5.67001003023278,3.1335415138862427e-10,0.49959204294253967,999999.9846771725,6.028512151073175,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-60-200,JA Solar,Mono-c-Si,0,200.0,178.6,1.6351499999999999,1.65,0.991,60.0,7.83,36.12,7.17,27.88,0.003915000000000001,-0.11558399999999999,46.6,1.474444803262821,7.866542318587603,1.7368733904073525e-10,0.5598688696078264,119.96429906633833,8.838721650629155,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-200,JA Solar,Multi-c-Si,0,200.0,178.1,1.6351499999999999,1.65,0.991,60.0,7.8,36.15,7.11,28.12,0.00468,-0.119295,46.7,1.5149913331287579,7.838396088232351,3.2498226592829497e-10,0.518617022836672,105.35482713406073,10.915204714334989,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-205/SI,JA Solar,Mono-c-Si,0,205.0,183.1,1.2766400000000002,1.58,0.808,72.0,5.69,45.74,5.46,37.56,0.0034993500000000005,-0.16127924000000002,47.6,1.9542346568964113,5.6900019908937916,3.8921871081177755e-10,0.34977234747280345,999999.9947018957,7.874228443488133,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM5(L)-72-205/SI,JA Solar,Mono-c-Si,0,205.0,183.1,1.2766400000000002,1.58,0.808,72.0,5.69,45.74,5.46,37.56,0.0034993500000000005,-0.16127924000000002,47.6,1.9542346568964113,5.6900019908937916,3.8921871081177755e-10,0.34977234747280345,999999.9947018957,7.874228443488133,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-60-205,JA Solar,Mono-c-Si,0,205.0,183.2,1.6351499999999999,1.65,0.991,60.0,7.92,36.29,7.3,28.08,0.003960000000000001,-0.11612800000000001,46.6,1.4785706911348522,7.948256227569706,1.6894675743788442e-10,0.5437302507783979,152.40333285936305,8.475619478473853,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-205,JA Solar,Multi-c-Si,0,205.0,182.6,1.6351499999999999,1.65,0.991,60.0,7.89,36.32,7.24,28.32,0.0047339999999999995,-0.11985600000000002,46.7,1.5189387731148636,7.920646735493975,3.1514267969497054e-10,0.5032022815417901,129.54941053203103,10.517175073568529,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM5(L)(BK)-72-210/SI,JA Solar,Mono-c-Si,0,210.0,187.8,1.2766400000000002,1.58,0.808,72.0,5.73,45.9,5.55,37.86,0.00352395,-0.16184340000000003,47.6,1.974455138817953,5.730001246520576,4.5934850213007027e-10,0.21747223779292957,999999.8975485051,9.270321281415864,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM5(L)-72-210/SI,JA Solar,Mono-c-Si,0,210.0,187.8,1.2766400000000002,1.58,0.808,72.0,5.73,45.9,5.55,37.86,0.00352395,-0.16184340000000003,47.6,1.974455138817953,5.730001246520576,4.5934850213007027e-10,0.21747223779292957,999999.8975485051,9.270321281415864,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-60-210,JA Solar,Mono-c-Si,0,210.0,187.8,1.6351499999999999,1.65,0.991,60.0,8.0,36.46,7.43,28.28,0.004,-0.11667200000000001,46.6,1.48190393541228,8.01881073081213,1.622101511680369e-10,0.5285565702368825,224.78941403269673,8.008106525969497,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-210,JA Solar,Multi-c-Si,0,210.0,187.2,1.6351499999999999,1.65,0.991,60.0,7.97,36.49,7.36,28.52,0.004782,-0.12041700000000001,46.7,1.5231178913673489,7.993377849168767,3.06257657507591e-10,0.4888871330405577,166.67192223052183,10.152417393448587,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-215,JA Solar,Mono-c-Si,0,215.0,192.4,1.6351499999999999,1.65,0.991,60.0,8.09,36.63,7.55,28.48,0.004045,-0.117216,46.6,1.487277707381249,8.102999416157564,1.6079347492490052e-10,0.5135987287117425,319.63084781944946,7.818734376670733,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-215,JA Solar,Multi-c-Si,0,215.0,190.9,1.6351499999999999,1.65,0.991,60.0,8.06,36.66,7.49,28.72,0.00519064,-0.13351572,47.9,1.5312926906683153,8.07621443567403,3.173185358353533e-10,0.4733245623957094,235.2839749258937,-0.14069906009636643,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-220,JA Solar,Mono-c-Si,0,220.0,197.0,1.6351499999999999,1.65,0.991,60.0,8.17,36.8,7.67,28.68,0.004085,-0.11776,46.6,1.4918272063826423,8.175987269899963,1.572538000403343e-10,0.4995112047850793,681.6141842209864,7.520204421751749,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-220,JA Solar,Multi-c-Si,0,220.0,195.4,1.6351499999999999,1.65,0.991,60.0,8.14,36.83,7.61,28.92,0.005242160000000001,-0.13413486000000002,47.9,1.535676131349028,8.149692009805783,3.0929939135604286e-10,0.4598567835287899,386.2187040386937,-0.44363235613605073,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-225,JA Solar,Mono-c-Si,0,225.0,201.5,1.6351499999999999,1.65,0.991,60.0,8.26,36.97,7.79,28.88,0.00413,-0.11830399999999999,46.6,1.4973529404189378,8.260776641368595,1.562464778899167e-10,0.4854028785850161,5162.519277394157,7.3542080912991405,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-225,JA Solar,Multi-c-Si,0,225.0,200.0,1.6351499999999999,1.65,0.991,60.0,8.23,37.0,7.73,29.12,0.005300120000000001,-0.134754,47.9,1.541136283665979,8.234822887840103,3.0649956095383616e-10,0.4463095927378068,761.603913362721,-0.6183914008047569,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-225/MP,JA Solar,Multi-c-Si,0,225.0,198.3,1.6351499999999999,1.65,0.991,60.0,8.57,37.32,7.77,28.94,0.00726736,-0.12853008000000002,48.5,1.6172706690987155,8.61667140898084,7.800182203221043e-10,0.488510645532023,89.70239350115462,12.898731484018077,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-230,JA Solar,Mono-c-Si,0,230.0,206.1,1.6351499999999999,1.65,0.991,60.0,8.34,37.14,7.91,29.08,0.00417,-0.11884800000000001,46.6,1.5087920218918298,8.34000378315792,1.7009576883799998e-10,0.4533863613962757,999999.9183068213,8.004973850636427,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6(BK)-60-230,JA Solar,Multi-c-Si,0,230.0,204.5,1.6351499999999999,1.65,0.991,60.0,8.31,37.17,7.84,29.32,0.00535164,-0.13537314000000003,47.9,1.5467261837624253,8.31028272957031,3.039189192679232e-10,0.4336749179293239,12746.71942155576,-0.7767899351909999,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-230/MP,JA Solar,Multi-c-Si,0,230.0,202.8,1.6351499999999999,1.65,0.991,60.0,8.66,37.37,7.88,29.18,0.00734368,-0.12870227999999997,48.5,1.623179723687743,8.70046091289853,8.341179612382825e-10,0.45300981221834885,96.95939901897954,13.414527188277697,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-235,JA Solar,Mono-c-Si,0,235.0,210.7,1.6351499999999999,1.65,0.991,60.0,8.43,37.31,8.03,29.28,0.004215,-0.11939200000000001,46.6,1.5202905281660781,8.430003566832191,1.852029062785366e-10,0.42290372178770513,999998.115991214,8.653973869921623,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-60-235/SI,JA Solar,Mono-c-Si,0,235.0,208.4,1.6351499999999999,1.65,0.991,60.0,8.49,37.19,7.74,30.36,0.005408130000000001,-0.12633443,48.0,1.61912525619227,8.514277065208407,8.58694438794492e-10,0.2656433284304412,92.89887719399853,15.728356332477587,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-235,JA Solar,Multi-c-Si,0,235.0,209.1,1.6351499999999999,1.65,0.991,60.0,8.39,37.34,7.96,29.52,0.00540316,-0.13599228000000002,47.9,1.5592729507464438,8.390003362007942,3.339527285020781e-10,0.40041249365242476,999999.9363168244,-0.09616519871334352,-0.4531,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-60-235/MP,JA Solar,Multi-c-Si,0,235.0,207.3,1.6351499999999999,1.65,0.991,60.0,8.71,37.51,7.99,29.42,0.007386080000000001,-0.12918443999999998,48.5,1.626510043440313,8.740060757486923,8.143619281310596e-10,0.43202468200014993,125.17768092141146,13.118733851000316,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-240,JA Solar,Mono-c-Si,0,240.0,215.3,1.6351499999999999,1.65,0.991,60.0,8.51,37.48,8.14,29.48,0.004255,-0.11993599999999999,46.6,1.5321070289772025,8.510259317470812,2.0212934182701384e-10,0.3915335078236375,12849.000846310357,9.340123049791694,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-60-240/SI,JA Solar,Mono-c-Si,0,240.0,212.9,1.6351499999999999,1.65,0.991,60.0,8.54,37.49,7.85,30.56,0.00543998,-0.12735353,48.0,1.623064313529875,8.559687829398435,7.668723490340676e-10,0.27447475525226345,119.05907239299982,14.585833254293513,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-240,JA Solar,Multi-c-Si,0,240.0,213.7,1.6351499999999999,1.65,0.991,60.0,8.48,37.51,8.08,29.72,0.00546112,-0.13661142,47.9,1.5713121190334056,8.48000314149814,3.63928882172842e-10,0.37018578463891894,999998.9304122023,0.5139524834189685,-0.4531,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-60-240/MP,JA Solar,Multi-c-Si,0,240.0,211.9,1.6351499999999999,1.65,0.991,60.0,8.76,37.58,8.09,29.66,0.0074284799999999995,-0.12942552,48.5,1.6298259597993374,8.781678040022385,8.282882149720077e-10,0.40267935537102634,162.72099269779005,13.205025279308378,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-245/SI,JA Solar,Mono-c-Si,0,245.0,217.5,1.6351499999999999,1.65,0.991,60.0,8.58,37.74,7.96,30.76,0.005465460000000001,-0.12820278000000002,48.0,1.625323969551709,8.593697189432543,6.898177416095039e-10,0.2769873799659428,173.5065524169704,13.529243768070831,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-245,JA Solar,Multi-c-Si,0,245.0,218.3,1.6351499999999999,1.65,0.991,60.0,8.56,37.68,8.19,29.92,0.005512640000000001,-0.13723056000000003,47.9,1.5837193325309624,8.560225251005306,3.977053053059839e-10,0.33889446294065567,12878.802277080202,1.1621466242286036,-0.4531,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-60-245,JA Solar,Multi-c-Si,0,245.0,218.3,1.6351499999999999,1.65,0.991,60.0,8.56,37.68,8.19,29.92,0.005512640000000001,-0.13723056000000003,47.9,1.5837193325309624,8.560225251005306,3.977053053059839e-10,0.33889446294065567,12878.802277080202,1.1621466242286036,-0.4531,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-60-245/3BB,JA Solar,Multi-c-Si,0,245.0,218.3,1.6351499999999999,1.65,0.991,60.0,8.78,37.45,8.27,29.63,0.005267999999999999,-0.13482000000000002,46.3,1.6063070055758362,8.780845315440759,6.573347071518544e-10,0.3902346271658189,4053.255892163551,6.435643103748685,-0.487,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-245/MP,JA Solar,Multi-c-Si,0,245.0,216.4,1.6351499999999999,1.65,0.991,60.0,8.81,37.64,8.19,29.9,0.007470880000000001,-0.12963216,48.5,1.6329870660058177,8.82427307009088,8.455886351821729e-10,0.37282001123399483,230.12187363327237,13.325539482134891,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-250/SI,JA Solar,Mono-c-Si,0,250.0,222.1,1.6351499999999999,1.65,0.991,60.0,8.62,37.92,8.07,30.96,0.005490940000000001,-0.12881424000000002,48.0,1.6266007472520456,8.627496829382519,6.386261525390292e-10,0.2704259820027806,310.9411412890763,12.746707839769435,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-60-250,JA Solar,Multi-c-Si,0,250.0,222.9,1.6351499999999999,1.65,0.991,60.0,8.65,37.85,8.3,30.12,0.0055706,-0.13784970000000002,47.9,1.594872090957352,8.650248160784848,4.266218462592097e-10,0.3135745965505869,10930.176118410365,1.6523724384055256,-0.4531,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-60-250,JA Solar,Multi-c-Si,0,250.0,222.9,1.6351499999999999,1.65,0.991,60.0,8.65,37.85,8.3,30.12,0.0055706,-0.13784970000000002,47.9,1.594872090957352,8.650248160784848,4.266218462592097e-10,0.3135745965505869,10930.176118410365,1.6523724384055256,-0.4531,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-60-250/3BB,JA Solar,Multi-c-Si,0,250.0,222.9,1.6351499999999999,1.65,0.991,60.0,8.84,37.54,8.34,29.98,0.0053040000000000006,-0.135144,46.3,1.6177151137076295,8.840178798675977,7.384199297597688e-10,0.3486789396150574,17239.470065712183,7.382438215560266,-0.487,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-250/MP,JA Solar,Multi-c-Si,0,250.0,221.0,1.6351499999999999,1.65,0.991,60.0,8.86,37.71,8.29,30.14,0.00751328,-0.12987324,48.5,1.6363178538696583,8.86785506200376,8.59903266379835e-10,0.34495646592914003,389.0887325781242,13.409942364645254,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-250,JA Solar,Multi-c-Si,0,250.0,222.8,1.95227,1.97,0.991,72.0,7.8,43.6,7.09,35.26,0.00468,-0.14388,46.7,1.8733874891066002,7.82826082387442,5.802997323442486e-10,0.3992313814230184,110.18804908298594,16.27682275287154,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-255/SI,JA Solar,Mono-c-Si,0,255.0,226.6,1.6351499999999999,1.65,0.991,60.0,8.64,38.1,8.18,31.16,0.005503680000000001,-0.1294257,48.0,1.626089194815994,8.640095550695246,5.763998379229e-10,0.2648515456346873,23949.16815383604,11.75177219383259,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-255,JA Solar,Mono-c-Si,0,255.0,228.1,1.95227,1.97,0.991,72.0,8.0,44.5,7.3,34.93,0.004,-0.1424,46.6,1.8379441455770475,8.03735766008927,2.345675495443097e-10,0.5807189016018948,124.35874076848722,11.335374809942232,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-255/3BB,JA Solar,Multi-c-Si,0,255.0,230.1,1.6351499999999999,1.65,0.991,60.0,8.98,37.82,8.42,30.29,0.00449,-0.11724200000000001,47.9,1.4937567672282575,8.991271164914052,8.949042903512838e-11,0.3685181705177303,293.6070412613587,5.302452327587107,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-255/4BB,JA Solar,Multi-c-Si,0,255.0,236.0,1.6351499999999999,1.65,0.991,60.0,8.9,37.61,8.34,30.59,0.0037380000000000004,-0.11320609999999999,43.46,1.4508071830751725,8.912354244998676,4.824350488203028e-11,0.3162188634722438,227.8041232530051,3.3936307217445574,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-255/MP,JA Solar,Multi-c-Si,0,255.0,225.6,1.6351499999999999,1.65,0.991,60.0,8.91,37.78,8.4,30.36,0.0075556799999999995,-0.13011432,48.5,1.6380416979095154,8.91126675195753,8.560511629744888e-10,0.32066973931199966,2255.51348198074,13.293305386524516,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-255,JA Solar,Multi-c-Si,0,255.0,227.4,1.95227,1.97,0.991,72.0,7.9,43.8,7.16,35.61,0.00474,-0.14454,46.7,1.8911671328805513,7.92835906959246,6.553528562936073e-10,0.3641902135303445,101.45265574448054,17.321554441537366,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-260/SI,JA Solar,Mono-c-Si,0,260.0,234.6,1.6351499999999999,1.65,0.991,60.0,8.92,38.08,8.44,30.81,0.003568,-0.11804799999999999,47.5,1.5076080158943668,8.922625405748796,9.531975075073541e-11,0.3295193071722791,1119.5651689907252,5.988782946601463,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-260,JA Solar,Mono-c-Si,0,260.0,232.7,1.95227,1.97,0.991,72.0,8.1,44.6,7.4,35.14,0.004050000000000001,-0.14272,46.6,1.8449887203524893,8.135454864505105,2.469900022724e-10,0.5535752617204885,126.46952699505381,11.68563436986247,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-260/3BB,JA Solar,Multi-c-Si,0,260.0,234.7,1.6351499999999999,1.65,0.991,60.0,9.04,37.98,8.49,30.63,0.00452,-0.117738,47.9,1.5046145188149207,9.0494901889696,9.734639929914942e-11,0.3383332403628785,322.2836452164343,5.958685788376678,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-260/4BB,JA Solar,Multi-c-Si,0,260.0,240.7,1.6351499999999999,1.65,0.991,60.0,9.04,37.84,8.44,30.81,0.0037968,-0.11389840000000001,43.46,1.463241083568721,9.05551129393173,5.196055825232653e-11,0.3085805832691503,179.84112341411225,3.8978060236435175,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-260/4BB/RE,JA Solar,Multi-c-Si,0,260.0,238.0,1.6351499999999999,1.65,0.991,60.0,9.04,37.98,8.51,30.55,0.0043392,-0.11431979999999999,46.25,1.4568962662320357,9.048889495202586,4.2649693417570887e-11,0.36017022439061835,366.26814965622555,2.1435668648810275,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-260/MP,JA Solar,Multi-c-Si,0,260.0,230.1,1.6351499999999999,1.65,0.991,60.0,8.96,37.84,8.51,30.57,0.007598080000000001,-0.13032096,48.5,1.6434531822595728,9.00851368907117,9.018940412383742e-10,0.2953302723676775,999999.979061403,13.67432036610233,-0.472,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-260,JA Solar,Multi-c-Si,0,260.0,232.0,1.95227,1.97,0.991,72.0,8.0,43.8,7.27,35.76,0.0048,-0.14454,46.7,1.8930397264818408,8.025313029795186,6.808954936731794e-10,0.3356371368859548,106.0756986785154,17.55888178832755,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-265/SI,JA Solar,Mono-c-Si,0,265.0,239.2,1.6351499999999999,1.65,0.991,60.0,9.0,38.26,8.52,31.11,0.0036,-0.118606,47.5,1.5184597808117266,9.002437160760145,1.0232724500593487e-10,0.3069755825264864,1133.606323234331,6.518535195394854,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-265,JA Solar,Mono-c-Si,0,265.0,237.3,1.95227,1.97,0.991,72.0,8.2,44.6,7.5,35.33,0.0040999999999999995,-0.14272,46.6,1.8497143306286215,8.23312493545726,2.6615357635597036e-10,0.5166180664268807,127.88759852627338,12.24844610511421,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-265,JA Solar,Multi-c-Si,0,265.0,235.5,1.938396,1.956,0.991,72.0,8.1,44.0,7.37,35.96,0.0052164,-0.160248,47.9,1.9082905512135635,8.124240827060342,7.480740823552933e-10,0.3254445401718469,108.74633160343414,7.08657396853771,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-265/3BB,JA Solar,Multi-c-Si,0,265.0,239.4,1.6351499999999999,1.65,0.991,60.0,9.1,38.14,8.56,30.96,0.00455,-0.118234,47.9,1.5151646578603948,9.107883046787977,1.0523657605494689e-10,0.3100525782143097,357.9172941535248,6.565807785240344,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-265/4BB,JA Solar,Multi-c-Si,0,265.0,245.4,1.6351499999999999,1.65,0.991,60.0,9.08,38.05,8.54,31.02,0.0038136000000000003,-0.1145305,43.46,1.4669256081300996,9.08931973925503,4.868037755609732e-11,0.30383255249005353,296.01683523899226,3.2885364154230516,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-265/4BB/RE,JA Solar,Multi-c-Si,0,265.0,242.7,1.6351499999999999,1.65,0.991,60.0,9.1,38.14,8.58,30.89,0.004368,-0.1148014,46.25,1.467308296571983,9.107325887014932,4.637102493305593e-11,0.33056125023391125,410.61341792254507,2.777087837416633,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-270/SI,JA Solar,Mono-c-Si,0,270.0,243.8,1.6351499999999999,1.65,0.991,60.0,9.09,38.46,8.62,31.33,0.003636,-0.119226,47.5,1.5266057031374636,9.091139685422716,1.0389627274325885e-10,0.2978150128985785,2375.3394763409124,6.557418882968475,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-270,JA Solar,Mono-c-Si,0,270.0,241.9,1.95227,1.97,0.991,72.0,8.3,44.7,7.6,35.33,0.00415,-0.14304000000000003,46.6,1.8503078159882997,8.333016140076099,2.576295210759062e-10,0.5239045692444677,131.70553119326186,11.839614958634991,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-270,JA Solar,Multi-c-Si,0,270.0,240.1,1.938396,1.956,0.991,72.0,8.2,44.0,7.5,36.0,0.0052807999999999996,-0.160248,47.9,1.9037478206444667,8.221089542533516,7.212107524598134e-10,0.316345789636765,123.00104322874735,6.646872827592386,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-270/3BB,JA Solar,Multi-c-Si,0,270.0,244.0,1.6351499999999999,1.65,0.991,60.0,9.16,38.3,8.63,31.29,0.00458,-0.11873,47.9,1.525677367317858,9.166433035579562,1.1358092014733623e-10,0.28227030012671167,401.92473984544,7.16261577759213,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-270/4BB,JA Solar,Multi-c-Si,0,270.0,250.2,1.6351499999999999,1.65,0.991,60.0,9.15,38.27,8.65,31.23,0.003843000000000001,-0.11519270000000001,43.46,1.4724423741565933,9.155115047029035,4.683658487846819e-11,0.29927644340064186,535.3576572228593,2.884236027388459,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-270/4BB/RE,JA Solar,Multi-c-Si,0,270.0,247.3,1.6351499999999999,1.65,0.991,60.0,9.16,38.3,8.65,31.21,0.0043968,-0.115283,46.25,1.477178217016212,9.165925231264188,4.9887733512124906e-11,0.304161129423118,470.2122082983727,3.326436599560186,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-275/SI,JA Solar,Mono-c-Si,0,275.0,248.5,1.6351499999999999,1.65,0.991,60.0,9.18,38.66,8.71,31.58,0.003672,-0.119846,47.5,1.5364361691420592,9.180884321032007,1.082662612796876e-10,0.28478826136848845,2956.3445511143054,6.825247934820486,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-275,JA Solar,Mono-c-Si,0,275.0,246.5,1.95227,1.97,0.991,72.0,8.4,44.8,7.7,35.71,0.004200000000000001,-0.14336,46.6,1.8625873564803264,8.429930291711411,2.89840710410913e-10,0.4723431428850812,132.56411676348134,12.798918404525299,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-275,JA Solar,Multi-c-Si,0,275.0,244.6,1.938396,1.956,0.991,72.0,8.25,44.2,7.53,36.52,0.005313,-0.16097640000000002,47.9,1.926313133782928,8.268663073597834,8.543260976362147e-10,0.2591065299171486,114.53788998905107,8.082191847663282,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-275/3BB,JA Solar,Multi-c-Si,0,275.0,248.7,1.6351499999999999,1.65,0.991,60.0,9.22,38.46,8.7,31.61,0.00461,-0.119226,47.9,1.5358974552506002,9.22514550048485,1.218877949595828e-10,0.2563111970634557,459.27299396760753,7.713294510423866,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-275/4BB,JA Solar,Multi-c-Si,0,275.0,254.9,1.6351499999999999,1.65,0.991,60.0,9.26,38.48,8.75,31.44,0.0038892,-0.11582479999999999,43.46,1.4818267586922431,9.265545131954305,4.846435200253775e-11,0.29220233200243617,487.9584002364808,3.0708223320722015,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-275/4BB/RE,JA Solar,Multi-c-Si,0,275.0,252.0,1.6351499999999999,1.65,0.991,60.0,9.22,38.46,8.72,31.54,0.0044256,-0.1157646,46.25,1.4872721633617805,9.2246698522912,5.382961093762894e-11,0.27688613398727685,546.6747402167608,3.9037391667897166,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-275/3BB,JA Solar,Multi-c-Si,0,275.0,245.7,1.938396,1.956,0.991,72.0,8.27,44.53,7.54,36.45,0.0033079999999999997,-0.13359000000000001,47.2,1.8645344494832325,8.295289460146432,3.3477099563340907e-10,0.3325350752638365,108.74353106858084,22.09256268404131,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-280/PR,JA Solar,Mono-c-Si,0,280.0,258.7,1.583,,,60.0,9.38,39.05,8.86,31.6,0.0033768,-0.1097305,45.1,1.4654442399257552,9.387008923303398,2.4877437991356492e-11,0.34028464704058603,455.4009335761978,4.636121919129954,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S02-280/PR,JA Solar,Mono-c-Si,0,280.0,256.6,1.59,,,60.0,9.38,39.05,8.86,31.6,0.0034706000000000003,-0.11051149999999998,46.46,1.4836552275593407,9.386393924180606,3.452461263382071e-11,0.3358872296946721,492.75253374128056,6.659958387130159,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-60-280/SI,JA Solar,Mono-c-Si,0,280.0,253.1,1.6351499999999999,1.65,0.991,60.0,9.27,38.86,8.8,31.82,0.0037079999999999995,-0.120466,47.5,1.5460008127976193,9.27062866928312,1.1228167199382659e-10,0.2733577689647502,4030.7803643021184,7.053279359284843,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-280,JA Solar,Mono-c-Si,0,280.0,251.1,1.95227,1.97,0.991,72.0,8.5,44.8,7.8,35.9,0.00425,-0.14336,46.6,1.8673084766166286,8.527770981509764,3.1187845777508994e-10,0.4379011220015596,134.03054627847698,13.358360773388632,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-280,JA Solar,Multi-c-Si,0,280.0,249.2,1.938396,1.956,0.991,72.0,8.32,44.2,7.62,36.75,0.00535808,-0.16097640000000002,47.9,1.9297807912167366,8.334958652240092,9.009576823290069e-10,0.22215442985388573,123.56226978470762,8.467169779878311,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-280/MP,JA Solar,Multi-c-Si,0,280.0,247.1,1.938396,1.956,0.991,72.0,8.56,45.33,7.82,35.81,0.0072588800000000005,-0.15611651999999998,48.5,1.978741211745105,8.59219849280483,9.272278626569745e-10,0.49197330955992413,130.79160111069467,14.5005205766269,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-60-280/4BB/RE,JA Solar,Multi-c-Si,0,280.0,256.7,1.6351499999999999,1.65,0.991,60.0,9.33,38.85,8.78,31.88,0.0044784000000000004,-0.1169385,46.25,1.5066314392567852,9.338548249881775,5.827265571572278e-11,0.2734335772576734,298.43949208999226,4.490265885244248,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-280/3BB,JA Solar,Multi-c-Si,0,280.0,250.3,1.938396,1.956,0.991,72.0,8.29,45.38,7.78,35.99,0.0033159999999999995,-0.13614,47.2,1.8379513290050542,8.297930485150983,1.5545165131219502e-10,0.5176298825993733,541.0958383467795,14.627354470871945,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-280/MP,JA Solar,Multi-c-Si,0,280.0,247.1,1.938396,1.956,0.991,72.0,8.56,45.33,7.82,35.81,0.0072588800000000005,-0.15611651999999998,48.5,1.978741211745105,8.59219849280483,9.272278626569745e-10,0.49197330955992413,130.79160111069467,14.5005205766269,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-285/SI,JA Solar,Mono-c-Si,0,285.0,252.9,1.938396,1.956,0.991,72.0,8.56,45.42,7.78,36.63,0.005452720000000001,-0.15429174,48.0,1.9663435608682127,8.591528970775247,7.588804266210049e-10,0.38981112975202187,105.8323042780128,14.49998458754728,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-285/PR,JA Solar,Mono-c-Si,0,285.0,263.4,1.583,,,60.0,9.46,39.25,8.99,31.7,0.0034056000000000004,-0.11029250000000002,45.1,1.4672731152668324,9.460925804863505,2.2799020272933324e-11,0.34690105363637724,3544.682546215672,3.804226664665303,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S02-285/PR,JA Solar,Mono-c-Si,0,285.0,261.3,1.59,,,60.0,9.46,39.25,8.99,31.7,0.0035002000000000006,-0.1110775,46.46,1.4854515216538087,9.460366451468891,3.164944459189566e-11,0.34258720436005796,8843.897400836682,5.816006535017377,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-285,JA Solar,Mono-c-Si,0,285.0,255.7,1.95227,1.97,0.991,72.0,8.6,44.8,7.87,36.21,0.0043,-0.14336,46.6,1.879597833322958,8.627693173467028,3.6753662857400146e-10,0.38595827707017993,119.8577481611452,14.777055543036345,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-285/SI,JA Solar,Mono-c-Si,0,285.0,252.9,1.938396,1.956,0.991,72.0,8.56,45.42,7.78,36.63,0.005452720000000001,-0.15429174,48.0,1.9663435608682127,8.591528970775247,7.588804266210049e-10,0.38981112975202187,105.8323042780128,14.49998458754728,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-285,JA Solar,Multi-c-Si,0,285.0,253.8,1.938396,1.956,0.991,72.0,8.38,44.4,7.7,37.01,0.005396720000000001,-0.1617048,47.9,1.9377495445331283,8.392918574247224,9.026014885831337e-10,0.20824056881986547,135.0811716095078,8.410138657199841,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-285/MP,JA Solar,Multi-c-Si,0,285.0,251.6,1.938396,1.956,0.991,72.0,8.6,45.42,7.9,36.08,0.0072927999999999995,-0.15642648,48.5,1.9833186061561126,8.625451248980818,9.441677871383128e-10,0.46053928405283195,155.61667646617812,14.612130195441129,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-285/3BB,JA Solar,Multi-c-Si,0,285.0,254.9,1.938396,1.956,0.991,72.0,8.38,45.41,7.9,36.08,0.003352000000000001,-0.13623,47.2,1.8369307693552552,8.383477870729275,1.5327200528284264e-10,0.5021766793653634,1210.00535910433,14.380107865888066,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-285/MP,JA Solar,Multi-c-Si,0,285.0,251.6,1.938396,1.956,0.991,72.0,8.6,45.42,7.9,36.08,0.0072927999999999995,-0.15642648,48.5,1.9833186061561126,8.625451248980818,9.441677871383128e-10,0.46053928405283195,155.61667646617812,14.612130195441129,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-290/SI,JA Solar,Mono-c-Si,0,290.0,257.4,1.938396,1.956,0.991,72.0,8.6,45.72,7.89,36.76,0.0054782,-0.15531084,48.0,1.965239581792682,8.625226617516839,6.536613671862847e-10,0.4087332237828493,139.3411611858631,13.045573048393406,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-290/PR,JA Solar,Mono-c-Si,0,290.0,268.1,1.583,,,60.0,9.57,39.46,9.12,31.8,0.0034452,-0.11088260000000001,45.1,1.4743078702148986,9.570003308490397,2.2749630428911047e-11,0.34569462721409894,999999.7592715168,3.685356407860567,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM60S02-290/PR,JA Solar,Mono-c-Si,0,290.0,266.0,1.588,,,60.0,9.57,39.46,9.12,31.8,0.0035409,-0.11167179999999999,46.46,1.4933029411661183,9.570003247610725,3.1976638935075984e-11,0.33932709736971733,999999.753402865,5.803583119078127,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-72-290,JA Solar,Mono-c-Si,0,290.0,260.3,1.95227,1.97,0.991,72.0,8.6,44.85,7.87,36.85,0.0043,-0.14352,46.6,1.8999299011974236,8.62177079472766,4.6114103494226427e-10,0.29622352475097014,117.01559345984617,16.908416379204525,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-290/SI,JA Solar,Mono-c-Si,0,290.0,257.4,1.938396,1.956,0.991,72.0,8.6,45.72,7.89,36.76,0.0054782,-0.15531084,48.0,1.965239581792682,8.625226617516839,6.536613671862847e-10,0.4087332237828493,139.3411611858631,13.045573048393406,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-290,JA Solar,Multi-c-Si,0,290.0,258.4,1.938396,1.956,0.991,72.0,8.42,44.4,7.74,37.47,0.0054224799999999995,-0.1617048,47.9,1.9518507637249185,8.42863638476463,1.0693450737149304e-09,0.1370801485070295,133.64561643816194,9.87664228376184,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-290/MP,JA Solar,Multi-c-Si,0,290.0,256.2,1.938396,1.956,0.991,72.0,8.64,45.5,7.98,36.34,0.00732672,-0.156702,48.5,1.9873938564858802,8.659418504500348,9.605585500794809e-10,0.4299753502062429,191.3117450196759,14.715235328501128,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-290/3BB,JA Solar,Multi-c-Si,0,290.0,259.5,1.938396,1.956,0.991,72.0,8.42,45.72,7.97,36.39,0.003368,-0.13716,47.2,1.8479444315071045,8.423793214322206,1.5157373786768173e-10,0.4933097624103319,999999.9840216722,14.215720387360411,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-290/MP,JA Solar,Multi-c-Si,0,290.0,256.2,1.938396,1.956,0.991,72.0,8.64,45.5,7.98,36.34,0.00732672,-0.156702,48.5,1.9873938564858802,8.659418504500348,9.605585500794809e-10,0.4299753502062429,191.3117450196759,14.715235328501128,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-295/SI,JA Solar,Mono-c-Si,0,295.0,262.0,1.938396,1.956,0.991,72.0,8.64,45.92,7.99,36.92,0.005503680000000001,-0.15599024000000003,48.0,1.9651476882548529,8.65870190516605,5.982161781522565e-10,0.4095000836081022,189.18293418367935,12.166546139983543,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-295/PR,JA Solar,Mono-c-Si,0,295.0,272.9,1.583,,,60.0,9.66,39.64,9.21,32.03,0.0034776,-0.11138840000000003,45.1,1.4830135102428006,9.660003212043156,2.3799208928912043e-11,0.33249051055535134,999999.7314040358,3.985074957817652,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM60S02-295/PR,JA Solar,Mono-c-Si,0,295.0,270.7,1.588,,,60.0,9.66,39.64,9.21,32.03,0.0035742,-0.1121812,46.46,1.502139385975102,9.660003150581842,3.3447661237846995e-11,0.3261223448270578,999999.7292218211,6.107865710767657,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-72-295,JA Solar,Mono-c-Si,0,295.0,264.9,1.95227,1.97,0.991,72.0,8.7,44.9,7.98,36.97,0.00435,-0.14368,46.6,1.9019326548769875,8.719902312634249,4.67028725764809e-10,0.28196926335352773,123.25867791219302,16.91116593933468,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-295/SI,JA Solar,Mono-c-Si,0,295.0,262.0,1.938396,1.956,0.991,72.0,8.64,45.92,7.99,36.92,0.005503680000000001,-0.15599024000000003,48.0,1.9651476882548529,8.65870190516605,5.982161781522565e-10,0.4095000836081022,189.18293418367935,12.166546139983543,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-295,JA Solar,Multi-c-Si,0,295.0,262.9,1.938396,1.956,0.991,72.0,8.48,44.6,7.8,37.82,0.00546112,-0.1624332,47.9,1.9656219150743504,8.486886142369169,1.1411449629241995e-09,0.1095419627664725,134.89641768410306,10.39549345516752,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-295/MP,JA Solar,Multi-c-Si,0,295.0,260.7,1.938396,1.956,0.991,72.0,8.68,45.59,8.07,36.56,0.00736064,-0.15701196,48.5,1.989007964845325,8.693143100298773,9.466170505945678e-10,0.40734244571481104,269.0182367467937,14.515814071797092,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-295,JA Solar,Multi-c-Si,0,295.0,264.1,1.95227,1.97,0.991,72.0,8.48,44.6,7.8,37.82,0.005088,-0.14718,46.7,1.9576959198069535,8.48706046126495,1.0407800912970626e-09,0.11171047506799711,134.17040047908165,21.080444069151756,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-295/3BB,JA Solar,Multi-c-Si,0,295.0,264.1,1.938396,1.956,0.991,72.0,8.48,45.9,8.06,36.6,0.003392,-0.1377,47.2,1.860610625887251,8.48000390272929,1.6392451306788186e-10,0.460089377000429,999999.9440280603,14.875879244226523,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-295/MP,JA Solar,Multi-c-Si,0,295.0,260.7,1.938396,1.956,0.991,72.0,8.68,45.59,8.07,36.56,0.00736064,-0.15701196,48.5,1.989007964845325,8.693143100298773,9.466170505945678e-10,0.40734244571481104,269.0182367467937,14.515814071797092,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-300/SI,JA Solar,Mono-c-Si,0,300.0,266.6,1.938396,1.956,0.991,72.0,8.68,46.1,8.08,37.13,0.005529160000000001,-0.1566017,48.0,1.9678442497931965,8.69302140518976,5.70668845702796e-10,0.40014587133431745,266.7351830358991,11.674824639212114,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-300/PR,JA Solar,Mono-c-Si,0,300.0,277.6,1.583,,,60.0,9.75,39.85,9.3,32.26,0.0035099999999999997,-0.11197850000000002,45.1,1.4923581759012876,9.75000314506938,2.466979745609473e-11,0.3225528140588248,999999.6810486071,4.209101470206898,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM60S02-300/PR,JA Solar,Mono-c-Si,0,300.0,275.5,1.59,,,60.0,9.75,39.85,9.3,32.26,0.0036075,-0.1127755,46.46,1.5116184913571038,9.75000308301465,3.466784953999731e-11,0.31618273897249116,999999.6784151986,6.3352943255459895,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM6-72-300,JA Solar,Mono-c-Si,0,300.0,269.5,1.95227,1.97,0.991,72.0,8.75,44.9,8.03,37.36,0.004375,-0.14368,46.6,1.9130928499903295,8.765942940295973,5.387911536154968e-10,0.22317048703000564,122.48317075544198,18.218391346188298,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-300/SI,JA Solar,Mono-c-Si,0,300.0,266.6,1.938396,1.956,0.991,72.0,8.68,46.1,8.08,37.13,0.005529160000000001,-0.1566017,48.0,1.9678442497931965,8.69302140518976,5.70668845702796e-10,0.40014587133431745,266.7351830358991,11.674824639212114,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-300,JA Solar,Multi-c-Si,0,300.0,267.5,1.938396,1.956,0.991,72.0,8.53,44.6,7.83,38.17,0.00549332,-0.1624332,47.9,1.979093485196821,8.533766503189309,1.3350834215164928e-09,0.055165632978554605,124.93362433438159,11.773997410595337,-0.4531,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-300/MP,JA Solar,Multi-c-Si,0,300.0,265.3,1.938396,1.956,0.991,72.0,8.73,45.67,8.13,36.9,0.0074030400000000005,-0.15728748,48.5,1.9996086485997862,8.741117497530123,1.0340257249737067e-09,0.3654358092938203,286.95808312003584,15.287756301512172,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-300,JA Solar,Multi-c-Si,0,300.0,271.7,1.938396,1.956,0.991,72.0,8.68,45.31,8.18,36.74,0.004907672,-0.14893397000000003,45.2,1.883754201798946,8.68397732403313,3.0888988141082e-10,0.36992441061994996,807.3129031468078,9.89557181606958,-0.4479,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-300/3BB,JA Solar,Multi-c-Si,0,300.0,270.6,1.938396,1.956,0.991,72.0,8.73,45.2,8.24,36.41,0.004365,-0.14012,47.9,1.7850121743163585,8.7346420835334,8.734238953193304e-11,0.4230183549204951,795.5373264262735,5.313306598889276,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-300/MP,JA Solar,Multi-c-Si,0,300.0,265.3,1.938396,1.956,0.991,72.0,8.73,45.67,8.13,36.9,0.0074030400000000005,-0.15728748,48.5,1.9996086485997862,8.741117497530123,1.0340257249737067e-09,0.3654358092938203,286.95808312003584,15.287756301512172,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-305/SI,JA Solar,Mono-c-Si,0,305.0,271.2,1.938396,1.956,0.991,72.0,8.73,46.28,8.13,37.52,0.005561010000000001,-0.15721316000000002,48.0,1.9827055147037038,8.742012408147767,6.245844944748259e-10,0.36369529743102696,264.3150752776388,12.444061553632421,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-305/PR,JA Solar,Mono-c-Si,0,305.0,282.4,1.583,,,60.0,9.86,40.05,9.37,32.57,0.0035495999999999995,-0.1125405,45.1,1.5024999452740035,9.861505475990992,2.6104173659642114e-11,0.3119579048518579,2043.1447062802833,4.5975184226691,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-305/SI,JA Solar,Mono-c-Si,0,305.0,275.1,1.938396,1.956,0.991,72.0,8.78,45.41,8.26,36.93,0.0035119999999999995,-0.14077099999999998,47.5,1.8080859848396376,8.787379888321444,1.0751668128379575e-10,0.3722940908938913,442.92572191499085,7.18131699176645,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-305/MP,JA Solar,Multi-c-Si,0,305.0,269.9,1.938396,1.956,0.991,72.0,8.77,45.74,8.19,37.24,0.00743696,-0.15752856,48.5,2.0087016020554906,8.778452535310633,1.1151553471819808e-09,0.3235259935530942,335.6772874989234,15.951347164762813,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-305,JA Solar,Multi-c-Si,0,305.0,276.3,1.938396,1.956,0.991,72.0,8.72,45.42,8.37,36.36,0.0049302880000000006,-0.14929554,45.2,1.8844732635120707,8.720265842701494,2.9707947338883245e-10,0.3565847566019173,11696.516857879888,9.491776616171736,-0.4479,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-305/3BB,JA Solar,Multi-c-Si,0,305.0,275.3,1.938396,1.956,0.991,72.0,8.79,45.35,8.31,36.71,0.004395,-0.14058500000000002,47.9,1.7942989314867783,8.793390435120784,9.234152084021522e-11,0.3962954510418203,1027.4308331565665,5.724001253284686,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-305/4BB,JA Solar,Multi-c-Si,0,305.0,282.3,1.938396,1.956,0.991,72.0,8.81,45.37,8.27,36.88,0.0037002000000000007,-0.13656369999999998,43.46,1.7480813662057781,8.820838918997659,4.6411342029255643e-11,0.38844657698474594,315.73392399024704,3.149067087068929,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-305/4BB/RE,JA Solar,Multi-c-Si,0,305.0,279.1,1.938396,1.956,0.991,72.0,8.76,45.48,8.41,36.28,0.0042048,-0.13689479999999998,46.25,1.738966959056831,8.760003935992774,3.838833484552297e-11,0.42809933036020675,952854.2095864052,1.5031797467710193,-0.385,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-305/MP,JA Solar,Multi-c-Si,0,305.0,269.9,1.938396,1.956,0.991,72.0,8.77,45.74,8.19,37.24,0.00743696,-0.15752856,48.5,2.0087016020554906,8.778452535310633,1.1151553471819808e-09,0.3235259935530942,335.6772874989234,15.951347164762813,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-305/SC,JA Solar,Multi-c-Si,0,305.0,281.2,1.88,,,72.0,8.84,45.27,8.29,36.78,0.003978,-0.13716810000000002,44.53,1.7484244927008377,8.85163668816586,4.9512912493914164e-11,0.38789537494529824,294.67105715604725,2.9362976370999725,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-310/SI,JA Solar,Mono-c-Si,0,310.0,275.8,1.938396,1.956,0.991,72.0,8.78,46.46,8.18,37.9,0.00559286,-0.15782462,48.0,1.997222661319028,8.791006189072178,6.800156485407176e-10,0.32918127740389286,262.59880766627975,13.170877037270275,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-310/PR,JA Solar,Mono-c-Si,0,310.0,288.4,1.583,,,60.0,9.91,40.3,9.44,32.84,0.0035676,-0.109213,44.12,1.5068702784644732,9.910003804075663,2.4056069789256098e-11,0.30525220559786476,795245.1306554495,7.712666442495361,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-310/SI,JA Solar,Mono-c-Si,0,310.0,279.7,1.938396,1.956,0.991,72.0,8.85,45.57,8.37,37.04,0.0035399999999999997,-0.141267,47.5,1.8090749840493585,8.853160274871813,1.0120986481403704e-10,0.37372344293405546,1046.571312543295,6.572158433606682,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6(BK)-72-310/MP,JA Solar,Multi-c-Si,0,310.0,274.4,1.938396,1.956,0.991,72.0,8.8,45.81,8.25,37.58,0.007462400000000001,-0.15776964,48.5,2.016450534624656,8.805484651616325,1.1840898868906059e-09,0.2828691591376479,453.85743410374766,16.477751502294698,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-310,JA Solar,Multi-c-Si,0,310.0,281.0,1.938396,1.956,0.991,72.0,8.78,45.61,8.41,36.49,0.004964211999999999,-0.14992007,45.2,1.889953335565411,8.780279891396829,2.9009600862560805e-10,0.3709618898746001,11636.873823055112,9.221207166997447,-0.4479,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-310/3BB,JA Solar,Multi-c-Si,0,310.0,279.9,1.938396,1.956,0.991,72.0,8.85,45.45,8.38,37.0,0.004425,-0.140895,47.9,1.802399183823001,8.852303600153032,9.86565675419299e-11,0.3653659598971425,1403.6678349297565,6.226733125676972,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-310/4BB,JA Solar,Multi-c-Si,0,310.0,287.0,1.938396,1.956,0.991,72.0,8.89,45.66,8.38,36.99,0.0037338000000000007,-0.1374366,43.46,1.7524332700749983,8.897490572560988,4.25574424470146e-11,0.40494712071070177,480.60148208431366,2.338904114461965,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-310/4BB/RE,JA Solar,Multi-c-Si,0,310.0,283.8,1.938396,1.956,0.991,72.0,8.83,45.68,8.49,36.51,0.004238400000000001,-0.1374968,46.25,1.7498390590893012,8.830302754586043,4.058979218948253e-11,0.4070316862512555,11871.308175691327,1.8968289165708438,-0.385,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-310/MP,JA Solar,Multi-c-Si,0,310.0,274.4,1.938396,1.956,0.991,72.0,8.8,45.81,8.25,37.58,0.007462400000000001,-0.15776964,48.5,2.016450534624656,8.805484651616325,1.1840898868906059e-09,0.2828691591376479,453.85743410374766,16.477751502294698,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-310/SC,JA Solar,Multi-c-Si,0,310.0,286.0,1.88,,,72.0,8.92,45.56,8.4,36.89,0.004014,-0.1380468,44.53,1.752764265017738,8.92830443748039,4.5385936949997215e-11,0.40437158186459166,434.34547335824413,2.1252107965972717,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6(BK)-72-315/SI,JA Solar,Mono-c-Si,0,315.0,280.3,1.938396,1.956,0.991,72.0,8.83,46.61,8.23,38.27,0.005624710000000001,-0.15833417,48.0,2.010865580714183,8.839924752679304,7.430630327217123e-10,0.29283347812591354,260.53244813175405,13.93673388840361,-0.4645,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-315/PR,JA Solar,Mono-c-Si,0,315.0,293.2,1.583,,,60.0,9.98,40.53,9.5,33.16,0.0035927999999999997,-0.10983630000000001,44.12,1.5183981684640557,9.980525904131639,2.5490669772519664e-11,0.2888642655237204,5481.733241804688,8.15878788053304,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-315/SI,JA Solar,Mono-c-Si,0,315.0,284.3,1.938396,1.956,0.991,72.0,8.92,45.73,8.48,37.15,0.003568,-0.141763,47.5,1.812558296930232,8.920003288090776,9.847266087985558e-11,0.36855744878904817,999999.9366334529,6.254550616313723,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6(BK)-72-315/MP,JA Solar,Multi-c-Si,0,315.0,279.0,1.938396,1.956,0.991,72.0,8.84,45.9,8.31,37.91,0.007496320000000001,-0.1580796,48.5,2.025429039139611,8.843694440817089,1.2614428911960275e-09,0.24620566170400743,589.1174202476113,17.03111661964148,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-315,JA Solar,Multi-c-Si,0,315.0,285.6,1.938396,1.956,0.991,72.0,8.91,45.91,8.57,36.72,0.0050377139999999996,-0.15090616999999998,45.2,1.9058705814089814,8.910262828345651,3.076780595561354e-10,0.3440572343907336,11663.750443827992,9.611176323397565,-0.4479,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-315/3BB,JA Solar,Multi-c-Si,0,315.0,284.5,1.938396,1.956,0.991,72.0,8.91,45.6,8.45,37.28,0.004455,-0.14136,47.9,1.8111153032425964,8.911291463030132,1.0337010447374475e-10,0.3423786377977176,2362.1231604024983,6.564328024167849,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-315/4BB,JA Solar,Multi-c-Si,0,315.0,291.7,1.938396,1.956,0.991,72.0,8.98,45.95,8.47,37.19,0.0037716000000000004,-0.1383095,43.46,1.7621520091822829,8.987029300495973,4.213508143451829e-11,0.4082303381667379,521.5182640226927,2.170954142752543,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-315/4BB/RE,JA Solar,Multi-c-Si,0,315.0,288.5,1.938396,1.956,0.991,72.0,8.89,45.98,8.58,36.73,0.0042672000000000005,-0.1383998,46.25,1.7639021476044303,8.890287561495235,4.2450622007831846e-11,0.386168047573508,11938.444374858733,2.210187766039386,-0.385,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-315/MP,JA Solar,Multi-c-Si,0,315.0,279.0,1.938396,1.956,0.991,72.0,8.84,45.9,8.31,37.91,0.007496320000000001,-0.1580796,48.5,2.025429039139611,8.843694440817089,1.2614428911960275e-09,0.24620566170400743,589.1174202476113,17.03111661964148,-0.472,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-315/SC,JA Solar,Multi-c-Si,0,315.0,290.7,1.88,,,72.0,9.01,45.85,8.49,37.09,0.0040545,-0.1389255,44.53,1.7624954788184133,9.017848851061695,4.4927559009163403e-11,0.4076520261734944,467.9595618367505,1.956382230270184,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S01-320/PR,JA Solar,Mono-c-Si,0,320.0,297.9,1.583,,,60.0,10.05,40.8,9.56,33.48,0.003618,-0.110568,44.12,1.5313205307549091,10.051330534919753,2.692652794604385e-11,0.2767887438124298,2090.683337294747,8.581355589791386,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-320/PR,JA Solar,Mono-c-Si,0,320.0,299.4,1.63,,,60.0,10.16,40.27,9.52,33.62,0.0042672000000000005,-0.10711820000000002,44.62,1.4801565275325048,10.173113275299121,1.5178835464314297e-11,0.2129435202864756,164.98594935706245,5.528983549609941,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S17-320/MR,JA Solar,Mono-c-Si,0,320.0,296.4,1.63,,,60.0,10.16,40.6,9.49,33.73,0.0041656,-0.105966,47.59,1.4844388545975213,10.176632891759963,1.3100350355645046e-11,0.23592524004345475,144.11206903177904,6.311592074602958,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-320/SI,JA Solar,Mono-c-Si,0,320.0,289.0,1.938396,1.956,0.991,72.0,8.99,45.86,8.57,37.35,0.0035960000000000002,-0.14216600000000001,47.5,1.8220587507161317,8.990003071761869,1.0540373733265674e-10,0.34162936207306444,999991.7430386407,6.770170571049635,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-320/3BB,JA Solar,Multi-c-Si,0,320.0,289.2,1.938396,1.956,0.991,72.0,8.97,45.75,8.52,37.56,0.004485,-0.141825,47.9,1.8198176866568787,8.97039577221504,1.0824162969250337e-10,0.3197878925002817,7247.8564131360445,6.8980312251740985,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-320/4BB,JA Solar,Multi-c-Si,0,320.0,296.5,1.938396,1.956,0.991,72.0,9.06,46.22,8.56,37.38,0.0038052000000000003,-0.1391222,43.46,1.7703159387565686,9.065519225179827,4.124693775618847e-11,0.4108580411476043,674.4377928456191,1.91586370874322,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-320/4BB/RE,JA Solar,Multi-c-Si,0,320.0,293.1,1.938396,1.956,0.991,72.0,9.05,46.48,8.74,37.17,0.004344000000000001,-0.1399048,46.25,1.7844622717478669,9.050283967738181,4.409402984479972e-11,0.3743779109143049,11931.365984722646,2.3764465356171924,-0.385,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP72S01-320/SC,JA Solar,Multi-c-Si,0,320.0,295.4,1.88,,,72.0,9.09,46.12,8.58,37.28,0.0040904999999999995,-0.1397436,44.53,1.7706699155520196,9.096337605312595,4.3974094675721874e-11,0.41027825847026206,588.4603682596572,1.7008645919725585,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-325/PR,JA Solar,Mono-c-Si,0,325.0,304.2,1.63,,,60.0,10.23,40.56,9.6,33.87,0.0042966,-0.10788960000000002,44.62,1.4898975985454326,10.242164282559404,1.5055563912819706e-11,0.21221552080860334,178.47043349516036,5.394067523437665,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S17-325/MR,JA Solar,Mono-c-Si,0,325.0,301.1,1.63,,,60.0,10.23,40.87,9.57,33.97,0.004194300000000001,-0.10667070000000001,47.59,1.4935508316275719,10.245524970522672,1.3031174749610644e-11,0.23410398253054107,154.26011567586224,6.200196475315371,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-325/SI,JA Solar,Mono-c-Si,0,325.0,293.6,1.938396,1.956,0.991,72.0,9.06,46.02,8.67,37.49,0.003624,-0.142662,47.5,1.8249217665950537,9.1297961273837,1.0200686026236436e-10,0.3547913824455645,999999.9407494948,6.360987248825208,-0.42,N,2025.7.3,6/23/2025,-2.0,bootstrapping +JA Solar JAP6-72-325/3BB,JA Solar,Multi-c-Si,0,325.0,293.8,1.938396,1.956,0.991,72.0,9.03,45.9,8.59,37.84,0.004515,-0.14229,47.9,1.829527399649646,9.030003164876208,1.1479196610937718e-10,0.2973536797778791,848509.9468796654,7.345330264570934,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-325/4BB,JA Solar,Multi-c-Si,0,325.0,301.2,1.938396,1.956,0.991,72.0,9.14,46.48,8.67,37.49,0.0038388000000000007,-0.1399048,43.46,1.77433796834755,9.141652157727629,3.8321106778123466e-11,0.4229122965526476,2339.6160809134244,1.2248829780577797,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-325/4BB/RE,JA Solar,Multi-c-Si,0,325.0,297.8,1.938396,1.956,0.991,72.0,9.21,46.98,8.64131879819197,37.61000000000001,0.004420800000000001,-0.1414098,46.25,1.8004263992133813,9.222670235365761,4.224857946068572e-11,0.46164887217513423,335.5727913650488,1.9228947282970845,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-325/SC,JA Solar,Multi-c-Si,0,325.0,300.1,1.88,,,72.0,9.17,46.38,8.69,37.39,0.0041265,-0.1405314,44.53,1.7746812186011711,9.172476596961074,4.0842308612870465e-11,0.42231827023582813,1563.701765145998,1.009104963792581,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S09-325/SC,JA Solar,Multi-c-Si,0,325.0,298.8,1.938,,,72.0,9.28,45.56,8.81,36.9,0.00464,-0.1362244,45.32,1.7571277064871924,9.280822758986154,5.086424657860953e-11,0.38463040505684637,4338.295633565404,4.025904476075985,-0.389,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-330/MR,JA Solar,Mono-c-Si,0,330.0,305.9,1.63,,,60.0,10.3,41.08,9.64,34.24,0.003193,-0.1063972,47.27,1.495204515344705,10.314923741574917,1.1752118395866977e-11,0.22418047248138412,154.7238551608045,6.210180259077927,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-330/PR,JA Solar,Mono-c-Si,0,330.0,309.0,1.63,,,60.0,10.3,40.84,9.67,34.13,0.004326000000000001,-0.10863440000000002,44.62,1.5004404032113545,10.311806974037658,1.5236457853642063e-11,0.20916349985905508,182.46707840485143,5.436265285527309,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S17-330/MR,JA Solar,Mono-c-Si,0,330.0,305.9,1.63,,,60.0,10.3,41.08,9.64,34.24,0.004223,-0.1072188,47.59,1.503003647453466,10.314658801719743,1.355602346397415e-11,0.22237065353226515,156.2486336042747,6.4813696246765575,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-330/SI,JA Solar,Mono-c-Si,0,330.0,298.3,1.938396,1.956,0.991,72.0,9.13,46.47,8.7,37.93,0.0036520000000000003,-0.144057,47.5,1.8478039121714969,9.130003037299923,1.0926866521425825e-10,0.3326224674288577,999999.9469615101,6.946820296351876,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-330/3BB,JA Solar,Multi-c-Si,0,330.0,298.5,1.938396,1.956,0.991,72.0,9.09,46.05,8.66,38.11,0.0045449999999999996,-0.142755,47.9,1.8400080367022211,9.09000244154978,1.22869968093687e-10,0.26855830931990643,999999.983699844,7.877448580378454,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-330/4BB,JA Solar,Multi-c-Si,0,330.0,306.0,1.938396,1.956,0.991,72.0,9.22,46.48,8.77659574468085,37.6,0.0038724000000000002,-0.1399048,43.46,1.7766210338944413,9.220003664995502,4.005961451047614e-11,0.39747052118800674,999996.522260278,1.509648700641174,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP6-72-330/4BB/RE,JA Solar,Multi-c-Si,0,330.0,302.5,1.938396,1.956,0.991,72.0,9.370000000000001,47.48,8.672798948751641,38.050000000000004,0.0044976,-0.1429148,46.25,1.8329446232002349,9.397394858215943,5.1146892993864015e-11,0.4540024336591197,155.2847195946332,3.4137819677763868,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-330/SC,JA Solar,Multi-c-Si,0,330.0,304.2,1.884,,,72.0,9.28,46.4,8.77,37.65,0.0040831999999999995,-0.137344,45.11,1.776506901061669,9.28555592658072,4.1806440996591443e-11,0.38705852005193386,646.4994075774649,3.5342738692513143,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S09-330/SC,JA Solar,Multi-c-Si,0,330.0,303.5,1.938,,,72.0,9.35,45.83,8.88,37.18,0.004675,-0.13703169999999998,45.32,1.7687532589555435,9.350586378771055,5.218191411587843e-11,0.37597701243491183,5995.07275359858,4.176647387344089,-0.389,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-335/MR,JA Solar,Mono-c-Si,0,335.0,310.7,1.63,,,60.0,10.38,41.32,9.72,34.48,0.0032178000000000003,-0.10701880000000001,47.27,1.5044307427308294,10.394405962136187,1.1956148463691639e-11,0.2190816275541602,157.85598207076472,6.28991657565699,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-335/PR,JA Solar,Mono-c-Si,0,335.0,313.8,1.63,,,60.0,10.38,41.12,9.75,34.36,0.004359600000000001,-0.10937920000000001,44.62,1.5102685402804377,10.391588746280748,1.5237482993820397e-11,0.2094964747008138,187.6452692903773,5.368455033842454,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM6-72-335/SI,JA Solar,Mono-c-Si,0,335.0,303.0,1.938396,1.956,0.991,72.0,9.21,46.76,8.76,38.24,0.0036840000000000006,-0.144956,47.5,1.859414999785349,9.210003684611905,1.103449137251227e-10,0.33723637619346297,843059.8514405681,6.956087188380752,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-335/PR,JA Solar,Mono-c-Si,0,335.0,309.1,1.884,,,72.0,9.38,46.68,8.83,37.96,0.0047838,-0.13210439999999998,45.85,1.7698746419330826,9.389744494241507,3.253125737992476e-11,0.379880488595471,365.6710107604919,5.985492291159498,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP6-72-335/4BB/RE,JA Solar,Multi-c-Si,0,335.0,307.3,1.938396,1.956,0.991,72.0,9.530000000000001,47.98,8.72,38.49,0.0045744,-0.1444198,46.25,1.8642644347669561,9.56987988763181,6.062939694217157e-11,0.44612759805301827,106.61003123840555,4.741101465738257,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-335/SC,JA Solar,Multi-c-Si,0,335.0,309.0,1.884,,,72.0,9.35,46.7,8.87,37.83,0.004114,-0.138232,45.11,1.7831062745789783,9.351982342185282,3.939640633824548e-11,0.3949334514943326,1862.7602779260628,2.9614554593191715,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S09-335/SC,JA Solar,Multi-c-Si,0,335.0,308.2,1.938,,,72.0,9.42,46.1,8.95,37.45,0.004710000000000001,-0.137839,45.32,1.7801240600478463,9.420338716125588,5.3321701738644346e-11,0.36876054139537034,10255.568704173544,4.2945857827693565,-0.389,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-340/MR,JA Solar,Mono-c-Si,0,340.0,315.4,1.63,,,60.0,10.46,41.55,9.79,34.73,0.0032426000000000004,-0.1076145,47.27,1.5144467631612897,10.4744657944848,1.2403181508412332e-11,0.21176481829918103,153.12397863567875,6.543413629668853,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-340/PR,JA Solar,Mono-c-Si,0,340.0,318.6,1.63,,,60.0,10.46,41.36,9.82,34.63,0.004393200000000001,-0.11001760000000001,44.62,1.5210193294238974,10.471638313610484,1.5883595321223592e-11,0.20093394305724233,180.59050535198776,5.661282177231198,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-340/PR,JA Solar,Mono-c-Si,0,340.0,313.9,1.884,,,72.0,9.46,46.86,8.91,38.18,0.004824600000000001,-0.1326138,45.85,1.778049952610551,9.469247209869941,3.348651211455313e-11,0.36853791685019727,377.0184541615936,6.159526011178222,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S01-340/SC,JA Solar,Multi-c-Si,0,340.0,313.7,1.884,,,72.0,9.42,47.0,8.97,38.02,0.0041448,-0.13912,45.11,1.792963999071176,9.420003704084566,3.88720126880664e-11,0.3931816434153296,999994.8641911113,2.780028977043158,-0.385,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAP72S09-340/SC,JA Solar,Multi-c-Si,0,340.0,312.9,1.938,,,72.0,9.48,46.39,9.01,37.74,0.004740000000000001,-0.1387061,45.32,1.7924086647647703,9.480156910688825,5.452304689704333e-11,0.3617133116478112,21853.50207188502,4.427928699956283,-0.389,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM60S10-345/MR,JA Solar,Mono-c-Si,0,345.0,320.2,1.63,,,60.0,10.54,41.76,9.86,34.99,0.0032673999999999997,-0.1081584,47.27,1.5243204352429318,10.55430218479743,1.2996919001851733e-11,0.2013437823857935,148.38036959347502,6.885296331281748,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-345/PR,JA Solar,Mono-c-Si,0,345.0,318.6,1.884,,,72.0,9.54,47.05,8.99,38.39,0.0048654,-0.13315149999999998,45.85,1.786160884667179,9.548791249215348,3.42375877064743e-11,0.3598179769754227,390.4636865449471,6.276180055875226,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAP72S09-345/SC,JA Solar,Multi-c-Si,0,345.0,317.6,1.938,,,72.0,9.55,46.68,9.07,38.04,0.0047750000000000015,-0.13957319999999998,45.32,1.804144477510699,9.550009030317694,5.535631881968343e-11,0.3534476997409365,373498.9535286113,4.493092519012186,-0.389,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-350/PR,JA Solar,Mono-c-Si,0,350.0,323.3,1.884,,,72.0,9.61,47.24,9.07,38.58,0.004901099999999999,-0.1336892,45.85,1.792879145621405,9.617460993195166,3.4298309420282256e-11,0.35420449055399256,456.22681716330834,6.222713150024108,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-355/PR,JA Solar,Mono-c-Si,0,355.0,328.1,1.884,,,72.0,9.69,47.45,9.16,38.76,0.0049419,-0.1342835,45.85,1.799675517919706,9.696129666196228,3.4057342962385604e-11,0.3518060330408742,556.1478112254955,6.084732499768604,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-360/PR,JA Solar,Mono-c-Si,0,360.0,332.8,1.884,,,72.0,9.78,47.66,9.24,38.96,0.0049878,-0.1348778,45.85,1.8088126537311693,9.78665606712597,3.494076434800238e-11,0.34652908599816123,509.1677254722833,6.2276799742632445,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-365/PR,JA Solar,Mono-c-Si,0,365.0,337.6,1.884,,,72.0,9.85,47.93,9.31,39.21,0.0050235,-0.13564189999999998,45.85,1.8194053125685032,9.85632462967204,3.5381896055050615e-11,0.3423839389144793,533.2299227284925,6.272789300454449,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D09-370/BP,JA Solar,Mono-c-Si,1,370.0,343.4,1.973,,,72.0,9.91,48.2,9.39,39.41,0.004063100000000001,-0.13014,45.1,1.791313239523696,9.915046438512144,2.029562810471894e-11,0.3530913252473655,693.3869844968724,6.597488515703892,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-370/PR,JA Solar,Mono-c-Si,0,370.0,343.6,1.88,,,72.0,9.91,48.18,9.38,39.45,0.0041622000000000004,-0.130086,44.91,1.8085512069688343,9.91560406098503,2.6495211170204027e-11,0.3423506071720238,605.3992824618421,8.910540083498379,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D09-375/BP,JA Solar,Mono-c-Si,1,375.0,348.2,1.973,,,72.0,9.97,48.51,9.44,39.73,0.0040877000000000005,-0.130977,45.1,1.8049915033428579,9.975726675957414,2.1064224628961967e-11,0.3450832104254154,600.781272175013,6.870212564392142,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-375/PR,JA Solar,Mono-c-Si,0,375.0,348.4,1.88,,,72.0,9.98,48.45,9.44,39.75,0.0041916,-0.13081500000000001,44.91,1.8211160061110931,9.986188981632655,2.7620543799137607e-11,0.33217754784792486,535.650645105063,9.21884017965277,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S09-375/PR,JA Solar,Mono-c-Si,0,375.0,349.4,1.938,,,72.0,10.06,48.47,9.55,39.27,0.0038228000000000003,-0.1298996,44.35,1.7835952450349462,10.063213120667339,1.58086767819102e-11,0.395169025033058,1237.2397321971262,5.147303202239176,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D09-380/BP,JA Solar,Mono-c-Si,1,380.0,353.0,1.973,,,72.0,10.03,48.81,9.5,40.02,0.0041123,-0.13178700000000002,45.1,1.8168899566559102,10.035455248234241,2.1428916278170247e-11,0.3397664835300924,624.6934602355708,6.965784706453049,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-380/PR,JA Solar,Mono-c-Si,0,380.0,353.2,1.88,,,72.0,10.05,48.71,9.5,40.03,0.004221000000000001,-0.13151700000000002,44.91,1.8330305686182553,10.056739061087066,2.8665498677803932e-11,0.32349953684502114,482.43670113624654,9.488747481846454,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S09-380/PR,JA Solar,Mono-c-Si,0,380.0,354.2,1.938,,,72.0,10.12,48.75,9.6,39.59,0.0038456,-0.13065000000000002,44.35,1.7966318274455497,10.12409487080453,1.655593543123171e-11,0.3839308567620433,948.8407757520977,5.494719618165244,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S31-385/MR,JA Solar,Mono-c-Si,0,385.0,359.1,1.9,,,54.0,13.52,36.71,12.64,30.46,0.006083999999999999,-0.09507890000000001,46.24,1.3350355085783134,13.541942133326556,1.5064857374598896e-11,0.1648408900183181,101.56938014850977,5.815606592603904,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D09-385/BP,JA Solar,Mono-c-Si,1,385.0,357.7,1.973,,,72.0,10.09,49.11,9.55,40.33,0.004136900000000001,-0.132597,45.1,1.8301587346858081,10.096088940098221,2.2210212417999786e-11,0.33206892575919045,550.2723535531688,7.228130867310036,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S01-385/PR,JA Solar,Mono-c-Si,0,385.0,357.9,1.88,,,72.0,10.11,48.98,9.56,40.29,0.0042462,-0.132246,44.91,1.8437825801305812,10.116459667214157,2.9092454270504767e-11,0.3187741777056659,498.9122344993591,9.565782279909916,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S09-385/PR,JA Solar,Mono-c-Si,0,385.0,359.0,1.94,,,72.0,10.17,49.04,9.65,39.9,0.0038645999999999997,-0.13142720000000002,44.35,1.808801692157367,10.173913737426439,1.7013761562869033e-11,0.3753988898694964,975.488748710708,5.685446450201624,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-385/PR,JA Solar,Mono-c-Si,0,385.0,360.2,1.95,,,72.0,10.11,48.62,9.57,40.24,0.0042462,-0.1293292,44.62,1.7705743055366432,10.116876093267456,1.1873554637537733e-11,0.30162484519814037,443.48252569044183,3.4401350312425993,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D30-390/MB,JA Solar,Mono-c-Si,1,390.0,365.2,1.9,,,54.0,13.61,36.85,12.73,30.64,0.005444,-0.091388,45.62,1.3218656762023027,13.632009755291852,1.03690892018794e-11,0.1620477829426265,100.20423572709412,7.24167225228924,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S31-390/MR,JA Solar,Mono-c-Si,0,390.0,363.9,1.9,,,54.0,13.61,36.85,12.73,30.64,0.0061245,-0.0954415,46.24,1.3412388445583618,13.630986749812031,1.552013112361156e-11,0.15863764428940935,102.87721374626646,6.0138686729611255,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D09-390/BP,JA Solar,Mono-c-Si,1,390.0,362.5,1.973,,,72.0,10.14,49.42,9.6,40.63,0.0041574,-0.13343400000000002,45.1,1.842517402715529,10.145857308992884,2.2588651939430275e-11,0.3270695856508627,566.2131991179673,7.331083799863449,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D10-390/MB,JA Solar,Mono-c-Si,1,390.0,366.1,1.987,,,72.0,10.02,49.05,9.4,41.49,0.0039077999999999995,-0.1290015,44.06,1.792115238218164,10.02996856828451,1.2709913793887435e-11,0.20245597058094456,203.50052010649674,5.3758607078073455,-0.331,N,2025.7.3,6/23/2025,4.0,bootstrapping +JA Solar JAM72S09-390/PR,JA Solar,Mono-c-Si,0,390.0,363.8,1.938,,,72.0,10.22,49.35,9.7,40.21,0.0038836000000000005,-0.13225800000000001,44.35,1.821334234195103,10.223722139741941,1.738201060290974e-11,0.36904556299634506,1013.300423247564,5.826261373507379,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-390/PR,JA Solar,Mono-c-Si,0,390.0,365.0,1.95,,,72.0,10.16,48.91,9.62,40.55,0.0042672000000000005,-0.1301006,44.62,1.782442196117874,10.166604085236411,1.2176905952780945e-11,0.2935959417575413,451.6802381093647,3.610326443655502,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D30-395/MB,JA Solar,Mono-c-Si,1,395.0,370.0,1.9,,,54.0,13.7,36.98,12.81,30.84,0.00548,-0.09171039999999998,45.62,1.3286928884286866,13.72149205231789,1.0915210621145526e-11,0.15331926892740827,97.73259240940827,7.636356315175947,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S31-395/MR,JA Solar,Mono-c-Si,0,395.0,368.7,1.9,,,54.0,13.7,36.98,12.81,30.84,0.006164999999999999,-0.0957782,46.24,1.3482103786566906,13.720481941211272,1.634149808070472e-11,0.14989745495489556,100.26369657200392,6.405064968866831,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D10-395/MB,JA Solar,Mono-c-Si,1,395.0,370.9,1.987,,,72.0,10.08,49.31,9.46,41.76,0.0039312,-0.1296853,44.06,1.802353170836297,10.089573524365708,1.2934783681267908e-11,0.19633410904318824,206.72092616134637,5.4735710661564365,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S09-395/PR,JA Solar,Mono-c-Si,0,395.0,368.6,1.938,,,72.0,10.27,49.64,9.76,40.48,0.0039026,-0.13303520000000002,44.35,1.827596812447515,10.270008203859181,1.6426347164193897e-11,0.3662215136927821,458460.62159847305,5.2846627677568625,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-395/MR,JA Solar,Mono-c-Si,0,395.0,369.7,1.95,,,72.0,10.27,49.3,9.62,41.06,0.0040053,-0.131631,44.08,1.8278459080711098,10.283500078818085,1.9412297935684348e-11,0.2655679562005264,202.0271852074537,7.1933383262772415,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-395/PR,JA Solar,Mono-c-Si,0,395.0,369.8,1.95,,,72.0,10.21,49.21,9.67,40.85,0.004288200000000001,-0.1308986,44.62,1.79426962857069,10.21636205811703,1.2407855372805581e-11,0.2878830063441169,462.0023056173988,3.726524659641803,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D30-400/MB,JA Solar,Mono-c-Si,1,400.0,374.8,1.9,,,54.0,13.79,37.07,12.9,31.01,0.005516,-0.0919336,45.62,1.33365787516165,13.810186943691576,1.1393948939624857e-11,0.1442883283938964,98.56550912030386,7.9552196627439535,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S30-400/MR,JA Solar,Mono-c-Si,0,400.0,374.7,1.9,,,54.0,13.79,37.07,12.9,30.01,0.005378099999999999,-0.09601130000000001,45.02,1.3288732279099347,13.818559929308089,1.0348162188013556e-11,0.23038572802046656,111.2404434797153,2.532771611641879,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S31-400/MR,JA Solar,Mono-c-Si,0,400.0,373.5,1.9,,,54.0,13.79,37.07,12.9,31.01,0.006205499999999999,-0.09601130000000001,46.24,1.353284226263126,13.80920712319246,1.7061686124359672e-11,0.1408641666346571,101.13523221126577,6.721298939861614,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D10-400/MB,JA Solar,Mono-c-Si,1,400.0,375.7,1.987,,,72.0,10.14,49.57,9.52,42.02,0.0039546,-0.13036910000000002,44.06,1.8123732092395892,10.14924003361269,1.3118520640128223e-11,0.19149253545722256,210.14364191929704,5.5421753571037025,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S09-400/PR,JA Solar,Mono-c-Si,0,400.0,373.3,1.94,,,72.0,10.33,49.92,9.81,40.78,0.0039254,-0.1337856,44.35,1.8442916534215943,10.333298608928416,1.8079137724530222e-11,0.35691320682104144,1117.7176911366128,6.070292563152046,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-400/MR,JA Solar,Mono-c-Si,0,400.0,374.5,1.95,,,72.0,10.33,49.58,9.68,41.33,0.0040287000000000005,-0.1323786,44.08,1.8387100709991164,10.343125889664522,1.9671917883370206e-11,0.2611967713553905,205.56036433038815,7.256728794493029,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-400/PR,JA Solar,Mono-c-Si,0,400.0,374.6,1.95,,,72.0,10.26,49.5,9.72,41.17,0.0043092,-0.13167,44.62,1.8063517547066346,10.266090167553282,1.2759157646784542e-11,0.2788323064180172,469.7439710497149,3.9203594564741793,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D30-405/MB,JA Solar,Mono-c-Si,1,405.0,379.6,1.9,,,54.0,13.87,37.23,12.98,31.21,0.005548,-0.09233039999999999,45.62,1.3405633661389011,13.889241610019424,1.1739593311939629e-11,0.13826834633764595,99.66847709114374,8.166511087248145,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S30-405/MR,JA Solar,Mono-c-Si,0,405.0,379.6,1.9,,,54.0,13.87,37.23,12.98,31.21,0.0054093,-0.09642569999999999,45.02,1.3579495378539008,13.88839691427241,1.6761733262149153e-11,0.135248395804899,101.96792939447195,6.599564561682153,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S31-405/MR,JA Solar,Mono-c-Si,0,405.0,378.3,1.9,,,54.0,13.87,37.23,12.98,31.21,0.0062415,-0.09642569999999999,46.24,1.3603153436672515,13.888283627233273,1.7581658327665847e-11,0.13483856674458589,102.28883486317733,6.930890857160111,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D10-405/MB,JA Solar,Mono-c-Si,1,405.0,380.5,1.987,,,72.0,10.2,49.82,9.58,42.28,0.003978,-0.13102660000000002,44.06,1.822210628437231,10.20887116305681,1.3339566918952712e-11,0.18566180361596168,213.47261795982118,5.633537988671331,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-405/MR,JA Solar,Mono-c-Si,0,405.0,379.3,1.95,,,72.0,10.39,49.86,9.74,41.6,0.0040521,-0.1331262,44.08,1.8495733421462077,10.402759754166198,1.9932334184547086e-11,0.2568803139509202,209.17224898440142,7.319293249104936,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-405/PR,JA Solar,Mono-c-Si,0,405.0,379.4,1.95,,,72.0,10.32,49.81,9.77,41.46,0.0043344,-0.13249460000000002,44.62,1.8189752821065066,10.326588951050619,1.3078063387644217e-11,0.27511146469411196,430.8956484357259,4.082987587755991,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D30-410/MB,JA Solar,Mono-c-Si,1,410.0,384.4,1.9,,,54.0,13.95,37.32,13.04,31.45,0.00558,-0.09255360000000001,45.62,1.3480342678378694,13.96840703270985,1.285911265031798e-11,0.12329209142192539,93.43845396202975,8.928417943037154,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S30-410/MR,JA Solar,Mono-c-Si,0,410.0,384.4,1.9,,,54.0,13.95,37.32,13.04,31.45,0.005440499999999999,-0.09665880000000002,45.02,1.365596946128121,13.967575688204585,1.8368851574001613e-11,0.12024326059377018,95.43828205769273,7.35200120383935,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D10-410/MB,JA Solar,Mono-c-Si,1,410.0,385.3,1.987,,,72.0,10.26,50.08,9.64,42.54,0.0040014,-0.1317104,44.06,1.8322293211062928,10.26855400688953,1.352523081058526e-11,0.18094865309657676,217.03667180722317,5.700434847828176,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S10-410/MR,JA Solar,Mono-c-Si,0,410.0,384.1,1.95,,,72.0,10.45,50.12,9.79,41.88,0.0040755,-0.1338204,44.08,1.861237870248643,10.462939506070079,2.0624096378792965e-11,0.2492453883879392,201.29163410679803,7.5693069058581885,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D30-415/MB,JA Solar,Mono-c-Si,1,415.0,389.2,1.9,,,54.0,14.02,37.45,13.13,31.61,0.005608,-0.09287600000000001,45.62,1.3525717860489788,14.036526758670563,1.2908374845234735e-11,0.11887461946257519,100.8438618437421,8.909920748565188,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54S30-415/MR,JA Solar,Mono-c-Si,0,415.0,389.2,1.9,,,54.0,14.02,37.45,13.13,31.61,0.005467799999999999,-0.09699550000000001,45.02,1.3701906876049073,14.035740055456463,1.8438949026720057e-11,0.11583486971926854,103.17656645981751,7.333790224524676,-0.333,N,2025.7.3,6/23/2025,4.0,bootstrapping +JA Solar JAM72S10-415/MR,JA Solar,Mono-c-Si,0,415.0,389.0,1.95,,,72.0,10.51,50.41,9.84,42.18,0.0040989,-0.1345947,44.08,1.8739049802763266,10.52311537568533,2.1297377220409862e-11,0.24242806104366818,194.26961107919377,7.802676834238519,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D41-425/MB,JA Solar,Mono-c-Si,1,425.0,402.9,1.89,,,54.0,13.7,38.56,13.02,32.64,0.005068999999999999,-0.08483200000000002,45.61,1.2906842932828768,13.708039495852471,1.4348763421757201e-12,0.13503213325465413,230.10650405184964,2.702770412617695,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D41-430/MB,JA Solar,Mono-c-Si,1,430.0,407.8,1.89,,,54.0,13.75,38.84,13.08,32.88,0.0050875,-0.08544800000000001,45.61,1.2995714237105245,13.757303155648293,1.4257118278846086e-12,0.13531316553301753,254.76056065871717,2.61177651302978,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D41-435/MB,JA Solar,Mono-c-Si,1,435.0,412.6,1.89,,,54.0,13.8,39.11,13.13,33.13,0.005106,-0.08604200000000001,45.61,1.308878649600614,13.807117148765444,1.4400793666656148e-12,0.13392896661288883,259.68541639451377,2.6660169642055895,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D20-435/MB,JA Solar,Mono-c-Si,1,435.0,408.1,2.22,,,72.0,11.29,49.15,10.8,40.28,0.0044031,-0.1292645,44.22,1.7549268049018303,11.290005845050436,7.75289157292987e-12,0.3194772182568328,617091.3998295794,0.15671606920536996,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78D10-435/MB,JA Solar,Mono-c-Si,1,435.0,407.0,2.15,,,78.0,10.32,52.74,9.82,44.31,0.0039216,-0.1387062,45.36,1.9007183742795908,10.323301864588345,9.129177798608166e-12,0.2505423429130795,783.071792075674,2.283137437170717,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78S10-435/MR,JA Solar,Mono-c-Si,0,435.0,408.6,2.11,,,78.0,10.4,52.73,9.78,44.5,0.003744,-0.1392072,44.07,1.9205349347609078,10.409609084872644,1.2141180841240071e-11,0.2225424301981955,240.85969804551806,4.299258867607059,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM54D41-440/MB,JA Solar,Mono-c-Si,1,440.0,417.5,1.89,,,54.0,13.85,39.38,13.18,33.37,0.005124500000000001,-0.086636,45.61,1.3180085299412245,13.856964687548802,1.4486452950464047e-12,0.13341157382056462,265.30268385083747,2.6850991747765023,-0.273,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D20-440/MB,JA Solar,Mono-c-Si,1,440.0,412.9,2.22,,,72.0,11.33,49.3,10.84,40.6,0.0044187,-0.129659,44.22,1.7639610850062606,11.330005574480934,8.248291978704486e-12,0.29856124234409126,606823.8401011584,0.6350847360539855,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S20-440/MR,JA Solar,Mono-c-Si,0,440.0,412.2,2.17,,,72.0,11.28,49.4,10.76,40.9,0.003948,-0.13091,44.61,1.7727838593847638,11.28135500964324,8.903983716786983e-12,0.2776212733669486,2311.1032678618526,0.5941422269915532,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78D10-440/MB,JA Solar,Mono-c-Si,1,440.0,411.8,2.15,,,78.0,10.37,53.01,9.85,44.68,0.0039406,-0.13941630000000002,45.36,1.9150805079576652,10.37425616697538,9.786839872058712e-12,0.23377730847905498,569.590130543386,2.832465241149705,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78S10-440/MR,JA Solar,Mono-c-Si,0,440.0,413.5,2.11,,,78.0,10.44,53.0,9.81,44.87,0.0037583999999999994,-0.13992000000000002,44.07,1.9341788028780316,10.449408741468494,1.2849808262688778e-11,0.20610679908746543,228.69742360306253,4.7525989840148,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D20-445/MB,JA Solar,Mono-c-Si,1,445.0,417.7,2.22,,,72.0,11.38,49.45,10.88,40.91,0.004438200000000001,-0.13005350000000002,44.22,1.7721880040477596,11.380005331306968,8.666904021149618e-12,0.278836527649441,595198.4114841524,1.005882753891199,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S20-445/MR,JA Solar,Mono-c-Si,0,445.0,417.0,2.17,,,72.0,11.32,49.56,10.8,41.21,0.003962000000000001,-0.131334,44.61,1.779525068599231,11.320012603159356,9.092473892889408e-12,0.2592274378393274,232830.09566223237,0.7301772495759504,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78D10-445/MB,JA Solar,Mono-c-Si,1,445.0,416.6,2.15,,,78.0,10.42,53.29,9.9,44.96,0.0039596,-0.14015270000000002,45.36,1.9258929641392069,10.424079770926106,9.935095160065307e-12,0.228847347119083,584.4909958004736,2.9172560268300165,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78S10-445/MR,JA Solar,Mono-c-Si,0,445.0,418.3,2.11,,,78.0,10.48,53.31,9.85,45.18,0.0037727999999999998,-0.1407384,44.07,1.9462854566017955,10.489102286978117,1.3046489652911891e-11,0.20104722131294872,231.47752759482273,4.848555496142886,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D20-450/MB,JA Solar,Mono-c-Si,1,450.0,422.5,2.22,,,72.0,11.42,49.61,10.92,41.21,0.0044538,-0.13047430000000002,44.22,1.7810664882448073,11.420005078362234,9.136548202703247e-12,0.2612521320188954,587497.0078493861,1.4122615731400388,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S20-450/MR,JA Solar,Mono-c-Si,0,450.0,421.8,2.17,,,72.0,11.36,49.7,10.84,41.52,0.003976,-0.13170500000000002,44.61,1.7911393619752534,11.361459671333224,1.0086355972365934e-11,0.23814085354629172,1853.3470594485889,1.563451429326877,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78S10-450/MR,JA Solar,Mono-c-Si,0,450.0,423.1,2.11,,,78.0,10.52,53.58,9.89,45.51,0.0037871999999999997,-0.1414512,44.07,1.9580937386962183,10.528552555734413,1.3459794965492037e-11,0.18964745345036976,233.27426792240578,5.0814546381117855,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D20-455/MB,JA Solar,Mono-c-Si,1,455.0,427.3,2.22,,,72.0,11.46,49.75,10.96,41.52,0.0044694,-0.1308425,44.22,1.789706865944588,11.460004763648387,9.699054743474186e-12,0.24094077256671034,579640.1636082911,1.8780492555643318,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S20-455/MR,JA Solar,Mono-c-Si,0,455.0,426.7,2.17,,,72.0,11.41,49.85,10.88,41.82,0.0039935000000000005,-0.1321025,44.61,1.7961776760122343,11.410007195475933,1.009580800056445e-11,0.22028708639498099,349314.82569753646,1.5264063775069399,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78S10-455/MR,JA Solar,Mono-c-Si,0,455.0,427.9,2.11,,,78.0,10.56,53.87,9.93,45.83,0.0038016,-0.1422168,44.07,1.9700467625206366,10.568135946083896,1.3769597482946874e-11,0.18152130419725795,235.60443467746444,5.242715669417368,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D20-460/MB,JA Solar,Mono-c-Si,1,460.0,432.1,2.22,,,72.0,11.5,49.91,11.01,41.79,0.004485,-0.1312633,44.22,1.7986996466432323,11.500004526891392,1.023218029379175e-11,0.2265580270925904,575546.4987520607,2.2938896329930656,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S20-460/MR,JA Solar,Mono-c-Si,0,460.0,431.5,2.17,,,72.0,11.45,50.01,10.92,42.13,0.0040075,-0.1325265,44.61,1.810173311584715,11.452004125174986,1.1452252805045792e-11,0.2009733495495471,1148.2041714734232,2.557193635564381,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D30-530/MB,JA Solar,Mono-c-Si,1,530.0,497.2,2.52,,,72.0,13.72,49.3,12.83,41.31,0.005350800000000001,-0.128673,44.81,1.792752126021059,13.739174429374927,1.5240583255618915e-11,0.18361315338679238,131.38187433728896,5.060465741923491,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S30-530/MR,JA Solar,Mono-c-Si,0,530.0,498.7,2.52,,,72.0,13.72,49.3,12.83,41.31,0.004802000000000001,-0.129166,43.9,1.7850554881748075,13.739458963226957,1.353399076426266e-11,0.18496492929355604,130.41387701991644,3.7084783153180156,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D30-535/MB,JA Solar,Mono-c-Si,1,535.0,502.0,2.52,,,72.0,13.79,49.45,12.9,41.47,0.005378099999999999,-0.12906450000000003,44.81,1.7986465902802307,13.808698519599623,1.5426908778255297e-11,0.18022352888826035,132.9133280440764,5.119562827227717,-0.33,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM72S30-535/MR,JA Solar,Mono-c-Si,0,535.0,503.5,2.52,,,72.0,13.79,49.45,12.9,41.47,0.0048265,-0.129559,43.9,1.7909231099960383,13.808980083315284,1.3699525910632222e-11,0.18157335276519643,131.92231553271293,3.7668448319063126,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D30-540/MB,JA Solar,Mono-c-Si,1,540.0,506.8,2.52,,,72.0,13.86,49.6,12.97,41.64,0.0054054,-0.12945600000000002,44.81,1.804759508240237,13.87815021204202,1.5666057422747846e-11,0.17598712493992866,134.38859845166556,5.20663849213629,-0.33,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM72S30-540/MR,JA Solar,Mono-c-Si,0,540.0,508.3,2.52,,,72.0,13.86,49.6,12.97,41.64,0.004851,-0.129952,43.9,1.7970077057408955,13.878428166223637,1.3912056099011365e-11,0.17733550689772956,133.37573046288287,3.852885742450493,-0.33,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM72D30-545/MB,JA Solar,Mono-c-Si,1,545.0,511.6,2.52,,,72.0,13.93,49.75,13.04,41.8,0.0054327,-0.1298475,44.81,1.8106546214233952,13.94769109770617,1.5855244665485057e-11,0.17267532251666562,135.9648389262491,5.265006187283774,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S30-545/MR,JA Solar,Mono-c-Si,0,545.0,513.2,2.52,,,72.0,13.93,49.75,13.04,41.8,0.0048755000000000005,-0.13034500000000002,43.9,1.8028759809326345,13.947966086106096,1.408013867950677e-11,0.17402178907063745,134.92774736301104,3.910533538842471,-0.33,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM72D30-550/MB,JA Solar,Mono-c-Si,1,550.0,516.4,2.52,,,72.0,14.0,49.9,13.11,41.96,0.0054600000000000004,-0.130239,44.81,1.8165501182310437,14.017239733105013,1.6045656876302725e-11,0.16939905922535298,137.56517046887777,5.3230649292137135,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72S30-550/MR,JA Solar,Mono-c-Si,0,550.0,518.0,2.52,,,72.0,14.0,49.9,13.11,41.96,0.004900000000000001,-0.130738,43.9,1.8087446992153708,14.017511757162703,1.4249324200122668e-11,0.1707436201153204,136.50318838667235,3.967884088007317,-0.33,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM72S30-555/MR,JA Solar,Mono-c-Si,0,555.0,522.8,2.52,,,72.0,14.07,50.05,13.18,42.12,0.004924500000000001,-0.131131,43.9,1.8146138226120379,14.087065075997948,1.4419604839312392e-11,0.1675004374890727,138.102588061128,4.024934813254281,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-580/MB,JA Solar,Mono-c-Si,1,580.0,543.1,2.52,,,72.0,13.84,51.95,13.17,44.02,0.006227999999999999,-0.12831650000000003,47.28,1.8510795698919529,13.844584567012134,8.901712645867536e-12,0.15662623742261386,472.8270226624033,6.060789515273825,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78D30-580/MB,JA Solar,Mono-c-Si,1,580.0,543.5,2.72,,,78.0,13.84,53.11,13.08,44.35,0.004844,-0.1311817,44.86,1.9188562569727547,13.85078965780647,1.3028072090658846e-11,0.21038326372565538,269.860680313653,9.569568953829638,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-585/MB,JA Solar,Mono-c-Si,1,585.0,547.9,2.52,,,72.0,13.89,52.16,13.23,44.22,0.0062505,-0.12883519999999998,47.28,1.858196306573319,13.893922329225832,8.893977414036303e-12,0.15490865813319224,548.5723274710352,6.017797797476969,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-585/MB-US,JA Solar,Mono-c-Si,1,585.0,556.1,2.52,,,72.0,14.0,53.7,13.03,44.9,0.004760000000000001,-0.114918,45.85,1.7651444778932397,14.032529141120277,8.284436641914292e-13,0.23744246543922665,102.19127840881465,0.8031170737986617,-0.26,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM78D30-585/MB,JA Solar,Mono-c-Si,1,585.0,548.3,2.72,,,78.0,13.88,53.2,13.13,44.56,0.004858,-0.131404,44.86,1.9241193448855323,13.889584198553981,1.3460122920209705e-11,0.19845705031523614,287.4088867485381,9.831609292372368,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-590/MB,JA Solar,Mono-c-Si,1,590.0,552.8,2.52,,,72.0,13.94,52.37,13.28,44.43,0.006273,-0.1293539,47.28,1.8661665007428268,13.943779414136191,8.993191880384509e-12,0.15225749795969654,561.586917735079,6.082278343742016,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-590/MB-US,JA Solar,Mono-c-Si,1,590.0,561.0,2.52,,,72.0,14.05,53.9,13.09,45.1,0.004777000000000001,-0.115346,45.85,1.7715000573428794,14.081229537745815,8.292313378611183e-13,0.23467741690038155,105.5800996725419,0.7761817705218569,-0.26,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM78D30-590/MB,JA Solar,Mono-c-Si,1,590.0,553.2,2.72,,,78.0,13.93,53.3,13.17,44.8,0.0048755000000000005,-0.13165100000000002,44.86,1.9315387868580824,13.939600928780992,1.4250459845029541e-11,0.1845028790608326,267.695466764435,10.313980485515936,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM66D45-595/LB,JA Solar,Mono-c-Si,1,595.0,558.6,2.64,,,66.0,15.9,47.5,15.15,39.27,0.0065190000000000005,-0.11732500000000001,45.954,1.6742995293129461,15.904257979872051,7.56466785893026e-12,0.19805643225528766,739.5754306001079,3.5147067696329577,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-595/MB,JA Solar,Mono-c-Si,1,595.0,557.6,2.52,,,72.0,13.99,52.58,13.33,44.64,0.0062955,-0.1298726,47.28,1.874136027806521,13.993639711332928,9.092728866765445e-12,0.14962664916929183,575.1216618320135,6.146158827007824,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-595/MB-US,JA Solar,Mono-c-Si,1,595.0,565.9,2.52,,,72.0,14.1,54.1,13.14,45.3,0.004794,-0.115774,45.85,1.7784467580067909,14.130731477702408,8.37717656367246e-13,0.2319123997671019,106.40441271630951,0.8316180999142042,-0.26,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78D30-595/MB,JA Solar,Mono-c-Si,1,595.0,558.0,2.72,,,78.0,13.98,53.4,13.21,45.05,0.004893000000000001,-0.13189800000000002,44.86,1.93917164359725,13.989475228670749,1.512635668768643e-11,0.16977191380125448,250.48592013168246,10.821753069610295,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM66D45-600/LB,JA Solar,Mono-c-Si,1,600.0,563.4,2.64,,,66.0,15.95,47.7,15.21,39.44,0.0065395,-0.11781900000000001,45.954,1.6808333569483407,15.953208121670107,7.529720772472283e-12,0.19792474740292906,984.0336723477805,3.445144190862114,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-600/MB,JA Solar,Mono-c-Si,1,600.0,562.4,2.52,,,72.0,14.04,52.79,13.38,44.95,0.006318,-0.13039130000000002,47.28,1.8841150412097116,14.043396244344708,9.469992697945241e-12,0.13851652674013307,572.6243013641258,6.4687290395249475,-0.312,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM72D40-600/MB-US,JA Solar,Mono-c-Si,1,600.0,570.7,2.52,,,72.0,14.15,54.3,13.19,45.5,0.004811000000000001,-0.116202,45.85,1.7853927920653894,14.180239603371941,8.462272014514708e-13,0.22916879639800472,107.23482148937782,0.886550205385433,-0.26,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM78D30-600/MB,JA Solar,Mono-c-Si,1,600.0,562.8,2.72,,,78.0,14.03,53.5,13.25,45.3,0.004910500000000001,-0.132145,44.86,1.9468066810426592,14.039238495451025,1.604937331089704e-11,0.1551341122383574,235.59372926004772,11.327926890145068,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM66D45-605/LB,JA Solar,Mono-c-Si,1,605.0,568.2,2.64,,,66.0,16.0,47.9,15.28,39.6,0.006560000000000001,-0.11831299999999999,45.954,1.6866722414952509,16.001277303143297,7.41399693643472e-12,0.1985463966269488,2487.0700937832153,3.2806627719724686,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM78D30-605/MB,JA Solar,Mono-c-Si,1,605.0,567.6,2.72,,,78.0,14.08,53.61,13.29,45.53,0.004928000000000001,-0.1324167,44.86,1.9542073359297543,14.089024379523508,1.68795918205308e-11,0.14306324122328476,223.2098553933043,11.75621804864048,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +JA Solar JAM66D45-610/LB,JA Solar,Mono-c-Si,1,610.0,573.0,2.64,,,66.0,16.05,48.1,15.34,39.77,0.0065805,-0.11880700000000001,45.954,1.6932077359307,16.05023289717034,7.380980060439323e-12,0.1984134156817642,13673.570527775883,3.2128652691528514,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM66D45-615/LB,JA Solar,Mono-c-Si,1,615.0,577.9,2.64,,,66.0,16.1,48.3,15.39,39.96,0.006601,-0.11930099999999999,45.954,1.7006387847622662,16.10010897563055,7.45325710684706e-12,0.1967940309238544,29074.281005372366,3.268603304511265,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM66D45-620/LB,JA Solar,Mono-c-Si,1,620.0,582.7,2.64,,,66.0,16.13,48.5,15.42,40.21,0.0066133,-0.119795,45.954,1.6974218516481674,16.130576339741605,6.286699020204724e-12,0.19271663314389378,5393.553916121342,1.8220420713771697,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM66D45-625/LB,JA Solar,Mono-c-Si,1,625.0,587.5,2.64,,,66.0,16.15,48.7,15.45,40.45,0.006621499999999999,-0.12028900000000001,45.954,1.7179051058728687,16.150002987628685,7.881021147783868e-12,0.18499013222758434,999999.6847539601,3.7153519941494326,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM66D45-630/LB,JA Solar,Mono-c-Si,1,630.0,592.4,2.64,,,66.0,16.18,48.9,15.48,40.7,0.0066338000000000005,-0.120783,45.954,1.7264681134275115,16.18000290373399,8.093601865122465e-12,0.17945843671882322,999982.7152903081,3.92597962129289,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +JA Solar JAM66D45-635/LB,JA Solar,Mono-c-Si,1,635.0,597.2,2.64,,,66.0,16.21,49.1,15.51,40.94,0.006646100000000001,-0.12127700000000001,45.954,1.7348583861341365,16.21000283072586,8.28647542640755e-12,0.17462621479661006,999999.766242182,4.110864307712291,-0.317,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jackery Inc JS-36A,Jackery Inc,Mono-c-Si,0,36.0,32.7,0.293,,,8.0,8.85,5.54,7.95,4.53,0.004867499999999999,-0.017229400000000002,44.9,0.22857794038046966,8.88924615123934,2.4670142588305607e-10,0.04039286780669903,9.108584594627244,14.14322882215649,-0.414,Y,2025.7.3,6/23/2025,4.0,first_pass +Jackery Inc JS-38A,Jackery Inc,Mono-c-Si,0,38.0,34.6,0.293,,,8.0,9.14,5.54,8.38,4.53,0.005027,-0.017229400000000002,44.9,0.2259725158556647,9.16611484764012,1.9747220915536664e-10,0.03951930331985007,13.831458950006601,11.746384704077215,-0.414,Y,2025.7.3,6/23/2025,4.0,first_pass +Jackery Inc JS-42A,Jackery Inc,Mono-c-Si,0,42.0,38.8,0.293,,,8.0,10.32,5.54,9.56,4.53,0.0038184,-0.014404000000000002,44.1,0.21099958387912465,10.345346322397507,3.9510584650218176e-11,0.03822497161726502,15.563666565692976,16.61534463021415,-0.379,Y,2025.7.3,6/23/2025,4.0,first_pass +Jackery Inc JS-45A,Jackery Inc,Mono-c-Si,0,45.0,41.6,0.293,,,8.0,10.36,5.54,9.93,4.53,0.0038331999999999997,-0.014404000000000002,44.1,0.2087856133898205,10.360000360771593,3.101830599964731e-11,0.03480949764290896,999999.653424639,14.19895375743136,-0.379,Y,2025.7.3,6/23/2025,-2.0,first_pass +Japan Solar (Infini Co Ltd) JS-250U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,250.0,223.7,1.63,,,60.0,8.7,37.8,8.3,30.2,0.005916,-0.135324,48.1,1.5656171848491207,8.700002913837702,2.8443564888561107e-10,0.3347460698458813,999998.6758645602,0.0006430530942262502,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-255U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,255.0,228.4,1.63,,,60.0,8.8,37.9,8.42,30.4,0.005984000000000001,-0.135682,48.1,1.5750055311614743,8.800002667295008,3.117997881252468e-10,0.30293166269354527,999957.2073381407,0.6532143505999825,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-260M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,260.0,234.6,1.63,,,60.0,9.37,39.1,8.44,30.92,0.005621999999999999,-0.121601,48.4,1.5701939022328866,9.430528132383715,1.3531576055063517e-10,0.41946992201597855,64.93564417817504,8.154765743884038,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-260U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,260.0,233.0,1.63,,,60.0,8.9,38.0,8.54,30.6,0.006052000000000001,-0.13604,48.1,1.5848713286908447,8.900218809798984,3.437786735044525e-10,0.2698477657859032,10976.00966881952,1.3596708486933637,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-265M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,265.0,239.2,1.63,,,60.0,9.43,39.2,8.55,31.08,0.005658,-0.121912,48.4,1.5710558855536785,9.48171800303112,1.3053011845329672e-10,0.40639130235831084,74.0993437074442,7.765524630803664,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-265U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,265.0,237.6,1.63,,,60.0,9.0,38.1,8.59,30.8,0.0061200000000000004,-0.136398,48.1,1.587354457740062,9.000002512543487,3.3901393524875756e-10,0.2790257275857821,999999.3509539624,1.1528015413152022,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JPS-270P-60-A,Japan Solar (Infini Co Ltd),Multi-c-Si,0,270.0,250.2,1.635,,,60.0,9.18,38.17,8.67,31.13,0.0038556,-0.11489170000000001,43.46,1.4688302472483432,9.185937395336586,4.713564428765344e-11,0.29995579941476724,463.771435637448,2.9134623895050775,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-270M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,270.0,243.9,1.63,,,60.0,9.48,39.3,8.66,31.24,0.005688,-0.12222299999999998,48.4,1.5711632477660582,9.522135493204695,1.244179603533101e-10,0.3939841013203486,88.64188132761926,7.279918863303439,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-270U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,270.0,242.2,1.63,,,60.0,9.09,38.39,8.61,31.44,0.0061812,-0.1374362,48.1,1.604891105910207,9.090575076223407,3.7114380004063834e-10,0.25613048507742325,4048.556383704491,1.8173389050090893,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-275P-60-A,Japan Solar (Infini Co Ltd),Multi-c-Si,0,275.0,254.9,1.635,,,60.0,9.29,38.38,8.77,31.34,0.0039018,-0.11552380000000001,43.46,1.4782110712898717,9.296357490058325,4.877095367783992e-11,0.2928911788571396,427.99267286653395,3.0998841558805434,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-275M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,275.0,248.5,1.63,,,60.0,9.54,39.4,8.77,31.4,0.005724,-0.122534,48.4,1.5722731417651332,9.574316221531465,1.2045398732198092e-10,0.3814591979166999,106.04666536521586,6.925372893352271,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-275U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,275.0,246.8,1.63,,,60.0,9.17,38.68,8.66,31.79,0.006235600000000001,-0.1384744,48.1,1.6229403250807375,9.172707849959139,4.069825018469437e-10,0.2401779495592937,813.3511030866491,2.5181683776183434,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-280M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,280.0,253.2,1.63,,,60.0,9.59,39.5,8.88,31.56,0.005754,-0.12284500000000001,48.4,1.5726447781023796,9.61577244111211,1.15258195188081e-10,0.3695680204516192,137.51733628305146,6.4768168826355925,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-280U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,280.0,251.5,1.63,,,60.0,9.25,39.02,8.73,32.1,0.0062900000000000005,-0.1396916,48.1,1.6386786189214086,9.25314976662383,4.190595730259735e-10,0.23598616257326763,693.026840619742,2.6913484429461025,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-285M-60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,285.0,257.6,1.63,,,60.0,9.33,39.1,9.05,31.5,0.0032841600000000004,-0.0950912,45.8,1.5984890597013144,9.330191415374562,2.2213478521532577e-10,0.2186789584675624,10658.917952430063,44.33570806588976,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-285M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,285.0,257.8,1.63,,,60.0,9.65,39.6,8.99,31.72,0.00579,-0.123156,48.4,1.573974331268131,9.668873832911148,1.1194800911028365e-10,0.35756794971357514,182.82088719747438,6.153006920475753,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-285U-PI60,Japan Solar (Infini Co Ltd),Multi-c-Si,0,285.0,256.1,1.63,,,60.0,9.32,39.35,8.81,32.42,0.0063376000000000005,-0.140873,48.1,1.652559089404044,9.322167018334214,4.2308993181598677e-10,0.22994088828308656,988.939574621787,2.7034178787555017,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-290M-60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,290.0,262.3,1.63,,,60.0,9.44,39.3,9.15,31.7,0.0033228800000000003,-0.09557759999999998,45.8,1.606964276550729,9.44015648086852,2.2579455923909736e-10,0.2175173576065816,13122.03859330179,44.388999306105006,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-290M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,290.0,262.5,1.63,,,60.0,9.71,39.7,9.1,31.87,0.0058260000000000004,-0.12346700000000001,48.4,1.5751231257974896,9.722410164088902,1.0841068353695848e-10,0.34711364927213056,271.58978591247615,5.804961912173004,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-295M-60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,295.0,267.0,1.63,,,60.0,9.56,39.5,9.25,31.9,0.0033651200000000005,-0.09606400000000001,45.8,1.6148990029148114,9.560191921271555,2.2781190433261736e-10,0.22144335363229162,11030.59191910086,44.34586938989202,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-295M-PI60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,295.0,267.2,1.63,,,60.0,9.74,39.8,9.2,32.07,0.005844,-0.12377799999999999,48.4,1.5761620556810092,9.744294814135035,1.0469434629019709e-10,0.331523548887746,751.8462479631338,5.454227254345166,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-295U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,295.0,262.2,1.94,,,72.0,8.8,44.12,8.29,35.62,0.005544,-0.15927319999999998,48.7,1.8503120960686277,8.803757845861698,3.85989033726888e-10,0.3722997674304247,871.8398045500792,1.6218895729517673,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-300M-60-A,Japan Solar (Infini Co Ltd),Mono-c-Si,0,300.0,277.6,1.583,,,60.0,9.75,39.85,9.3,32.26,0.0035099999999999997,-0.11197850000000002,45.1,1.4923581759012876,9.75000314506938,2.466979745609473e-11,0.3225528140588248,999999.6810486071,4.209101470206898,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JPS-300M-60-A-BB,Japan Solar (Infini Co Ltd),Mono-c-Si,0,300.0,275.5,1.585,,,60.0,9.75,39.85,9.3,32.26,0.0036075,-0.1127755,46.46,1.5116184913571038,9.75000308301465,3.466784953999731e-11,0.31618273897249116,999999.6784151986,6.3352943255459895,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-300M-60,Japan Solar (Infini Co Ltd),Mono-c-Si,0,300.0,271.6,1.63,,,60.0,9.65,39.7,9.35,32.1,0.0033968,-0.09655040000000001,45.8,1.6247918090271278,9.650153627594165,2.359879739732847e-10,0.20830264583037666,13084.347765035956,44.646490514000575,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +Japan Solar (Infini Co Ltd) JS-300U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,300.0,266.8,1.94,,,72.0,8.85,44.49,8.33,36.04,0.0055755,-0.1606089,48.7,1.8703741178167161,8.854536771361772,4.107584331391022e-10,0.35603523793664277,694.5276103902079,2.091551811651537,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-305U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,305.0,271.4,1.94,,,72.0,8.9,44.87,8.37,36.45,0.005607000000000001,-0.16198069999999998,48.7,1.8903190691764227,8.905220504311762,4.336596890415409e-10,0.34255973462974365,584.0015587521711,2.4976614582809034,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-310U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,310.0,276.0,1.94,,,72.0,8.95,45.24,8.41,36.87,0.005638499999999999,-0.1633164,48.7,1.9104087117773403,8.955812076826621,4.6055491498770753e-10,0.32658877449609247,502.91323686814127,2.955150567229523,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-315M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,315.0,283.7,1.94,,,72.0,9.32,46.8,8.55,36.99,0.0041008,-0.14976,48.8,1.8378950001888616,9.359552977754715,7.834831438250957e-11,0.5118722301045684,120.61416289302993,0.7504194776169905,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-315U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,315.0,280.6,1.94,,,72.0,9.01,45.59,8.45,37.28,0.0056763000000000004,-0.1645799,48.7,1.9310331546895096,9.017074379105006,4.967549754218895e-10,0.30922999273463364,393.8385016693179,3.5392542938537273,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-320M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,320.0,288.4,1.94,,,72.0,9.37,46.92,8.64,37.18,0.004122799999999999,-0.150144,48.8,1.84043942140371,9.402815283103964,7.688592811311896e-11,0.4969986416456602,141.91184631197933,0.5381761362393157,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-320U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,320.0,285.2,1.94,,,72.0,9.03,46.04,8.49,37.7,0.005688899999999999,-0.16620439999999997,48.7,1.9490045774212135,9.035315920509928,4.927267612402355e-10,0.30474288292891577,517.6580459470433,3.4445494047031944,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-325M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,325.0,293.0,1.94,,,72.0,9.43,47.04,8.72,37.36,0.0041492,-0.150528,48.8,1.8448456150915253,9.459115066957164,7.729689463598625e-11,0.48340580465027505,156.56899827725613,0.5209193435198689,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-325U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,325.0,289.8,1.94,,,72.0,9.11,46.34,8.53,38.11,0.0057393,-0.1672874,48.7,1.9711736557182766,9.117761839836222,5.53829494839149e-10,0.28061370847018896,329.353790179981,4.369263044451744,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-330M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,330.0,297.7,1.94,,,72.0,9.48,47.16,8.81,37.55,0.0041712,-0.150912,48.8,1.8474945936529192,9.502987628209636,7.595772518920467e-11,0.4690789376854998,193.44616317594728,0.32060948662965383,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-330U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,330.0,294.4,1.94,,,72.0,9.15,46.74,8.57,38.53,0.0057645000000000005,-0.1687314,48.7,1.9906394784729122,9.157384134904625,5.726515165955223e-10,0.26932124738510627,333.72763543994824,4.614877620859338,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-335M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,335.0,302.3,1.94,,,72.0,9.54,47.28,8.89,37.73,0.0041976,-0.151296,48.8,1.8519580433637595,9.559697110121922,7.641601162167162e-11,0.455984154177833,220.8490972870021,0.3095439216029185,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-335U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,335.0,299.0,1.94,,,72.0,9.2,47.12,8.61,38.94,0.005796,-0.1701032,48.7,2.010664567695542,9.20761824644822,6.014616207205846e-10,0.2566095969264852,309.8887289077615,4.988942805353463,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-340M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,340.0,307.0,1.94,,,72.0,9.59,47.4,8.98,37.91,0.0042196,-0.15168,48.8,1.8544327328939396,9.604162587151775,7.490863026768135e-11,0.44348061136839184,300.2967761334127,0.0902869547409796,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-340U-PI72,Japan Solar (Infini Co Ltd),Multi-c-Si,0,340.0,303.6,1.94,,,72.0,9.25,47.49,8.65,39.36,0.0058275,-0.1714389,48.7,2.030833037706429,9.257729541902677,6.352863633936311e-10,0.24146826264463178,288.9669045940178,5.4128798662807105,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-345M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,345.0,311.6,1.94,,,72.0,9.65,47.52,9.06,38.1,0.004246,-0.15206400000000003,48.8,1.8592194746137884,9.66124070900256,7.568671896331107e-11,0.429552614473497,368.76525851284254,0.11478633262011241,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-350M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,350.0,316.3,1.94,,,72.0,9.71,47.64,9.15,38.26,0.0042724,-0.152448,48.8,1.8622057134304628,9.717320352460431,7.470292970405156e-11,0.4196721365745932,556.6694769831472,-0.05326143453424589,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-355M-72-A,Japan Solar (Infini Co Ltd),Mono-c-Si,0,355.0,328.1,1.884,,,72.0,9.69,47.45,9.16,38.76,0.0049419,-0.1342835,45.85,1.799675517919706,9.696129666196228,3.4057342962385604e-11,0.3518060330408742,556.1478112254955,6.084732499768604,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-355M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,355.0,321.0,1.94,,,72.0,9.74,47.76,9.22,38.51,0.0042856,-0.152832,48.8,1.866784410754593,9.742751834129619,7.518667397544456e-11,0.3998014426771604,1415.080494898188,-0.04135550639990681,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-360M-72-A,Japan Solar (Infini Co Ltd),Mono-c-Si,0,360.0,332.8,1.884,,,72.0,9.78,47.66,9.24,38.96,0.0049878,-0.1348778,45.85,1.8088126537311693,9.78665606712597,3.494076434800238e-11,0.34652908599816123,509.1677254722833,6.2276799742632445,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JS-360M-PI72,Japan Solar (Infini Co Ltd),Mono-c-Si,0,360.0,325.6,1.94,,,72.0,9.82,47.88,9.32,38.63,0.0043208000000000005,-0.15321600000000002,48.8,1.8696895100467013,9.820157229005384,7.419749119798238e-11,0.3945804729094232,24644.26303976626,-0.223065374930795,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-365M-72-A-1500,Japan Solar (Infini Co Ltd),Mono-c-Si,0,365.0,337.6,1.88,,,72.0,9.85,47.93,9.31,39.21,0.0050235,-0.13564189999999998,45.85,1.8194053125685032,9.85632462967204,3.5381896055050615e-11,0.3423839389144793,533.2299227284925,6.272789300454449,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-370M-72-A-1500,Japan Solar (Infini Co Ltd),Mono-c-Si,0,370.0,343.6,1.88,,,72.0,9.91,48.18,9.38,39.45,0.0041622000000000004,-0.130086,44.91,1.8085512069688343,9.91560406098503,2.6495211170204027e-11,0.3423506071720238,605.3992824618421,8.910540083498379,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Japan Solar (Infini Co Ltd) JPS-375M-72-A-1500,Japan Solar (Infini Co Ltd),Mono-c-Si,0,375.0,348.4,1.88,,,72.0,9.98,48.45,9.44,39.75,0.0041916,-0.13081500000000001,44.91,1.8211160061110931,9.986188981632655,2.7620543799137607e-11,0.33217754784792486,535.650645105063,9.21884017965277,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT250PPg,Jetion Solar (China),Multi-c-Si,0,250.0,223.5,1.6268799999999999,1.64,0.992,60.0,8.86,37.6,8.28,30.3,0.00352628,-0.1311488,47.7,1.543957314747374,8.871947677638154,2.312625475772049e-10,0.3321301787293417,246.29671093431628,1.1917112394827012,-0.4467,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT255PPg,Jetion Solar (China),Multi-c-Si,0,255.0,228.1,1.6268799999999999,1.64,0.992,60.0,8.92,37.8,8.36,30.6,0.00355016,-0.1318464,47.7,1.5538763018317712,8.92924909306384,2.398304993321749e-10,0.3121836584813513,301.07586597375,1.4247392480937329,-0.4467,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT260PPg,Jetion Solar (China),Multi-c-Si,0,260.0,232.7,1.6268799999999999,1.64,0.992,60.0,8.98,38.0,8.44,30.9,0.0035740400000000005,-0.132544,47.7,1.563776984047178,8.98682361247489,2.4853907322682185e-10,0.2926378157070806,385.11662940463225,1.6528496741918308,-0.4467,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT265PPg,Jetion Solar (China),Multi-c-Si,0,265.0,237.3,1.6268799999999999,1.64,0.992,60.0,9.03,38.2,8.52,31.2,0.00359394,-0.13324160000000002,47.7,1.5727380831355757,9.03384163339546,2.5380304031580023e-10,0.2738862605765373,643.7869787142428,1.7663188555316385,-0.4467,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT270PPg,Jetion Solar (China),Multi-c-Si,0,270.0,242.0,1.6268799999999999,1.64,0.992,60.0,9.08,38.4,8.6,31.5,0.0036138400000000005,-0.1339392,47.7,1.5816841837178404,9.081229736142756,2.590621925025475e-10,0.25550436489740896,1886.5682198493407,1.876430141378567,-0.4467,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT300PAg,Jetion Solar (China),Multi-c-Si,0,300.0,269.7,1.9403519999999999,1.956,0.992,72.0,8.83,45.1,8.28,36.4,0.00255187,-0.1557754,46.6,1.8319064104862304,8.839374989474717,1.7720704319821802e-10,0.39648699908463103,373.4383481252592,0.17800795430319816,-0.4476,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT305PAg,Jetion Solar (China),Multi-c-Si,0,305.0,274.4,1.9403519999999999,1.956,0.992,72.0,8.88,45.3,8.35,36.7,0.00256632,-0.15646619999999997,46.6,1.8413067756311274,8.886928359900464,1.8179745647592608e-10,0.3765990757866583,482.68281279302505,0.3294730120469643,-0.4476,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT310PAg,Jetion Solar (China),Multi-c-Si,0,310.0,279.0,1.9403519999999999,1.956,0.992,72.0,8.93,45.5,8.42,37.0,0.00258077,-0.157157,46.6,1.8506952859409913,8.934704676176393,1.864321205645297e-10,0.35705959503181856,677.7390504868314,0.47819816109264335,-0.4476,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT315PAg,Jetion Solar (China),Multi-c-Si,0,315.0,283.6,1.9403519999999999,1.956,0.992,72.0,8.98,45.8,8.49,37.3,0.00259522,-0.15819319999999998,46.6,1.8618600624236314,8.982632226308786,1.854855802647027e-10,0.3498668982415952,1193.5922519244866,0.38248248227812937,-0.4476,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) JT320PAg,Jetion Solar (China),Multi-c-Si,0,320.0,288.3,1.9403519999999999,1.956,0.992,72.0,9.03,46.1,8.56,37.6,0.0026096699999999997,-0.1592294,46.6,1.873029930524764,9.030652122188458,1.845725341461323e-10,0.3427921203267161,4746.680889271945,0.28840582886336263,-0.4476,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT350SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,350.0,323.2,1.94,,,72.0,9.65,46.85,9.07,38.6,0.00458375,-0.1280879,46.4,1.758655349372522,9.661062163727108,2.5574340524432308e-11,0.313970495746683,273.889935973072,7.433435023301063,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT355SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,355.0,328.0,1.94,,,72.0,9.7,46.9,9.15,38.8,0.0046075,-0.1282246,46.4,1.7611640446327534,9.708001157883235,2.605365255041216e-11,0.2928883124743559,355.0756914535915,7.536353226408172,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT360SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,360.0,332.7,1.94,,,72.0,9.75,47.2,9.14,39.4,0.00463125,-0.1290448,46.4,1.7861626892644593,9.761005109952272,3.187498714664225e-11,0.24826019983160694,219.94664105752003,9.289525061211684,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT365SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,365.0,337.4,1.94,,,72.0,9.81,47.5,9.2,39.7,0.004659750000000001,-0.129865,46.4,1.7983197870521066,9.820601301729146,3.246418188790024e-11,0.24215442064725085,224.07954649826468,9.39594044570239,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT370SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,370.0,342.2,1.94,,,72.0,9.87,47.8,9.25,40.0,0.00468825,-0.13068519999999997,46.4,1.8114531714876076,9.880831037196744,3.3488690607590267e-11,0.23595506990612522,215.01879427734883,9.620390355569688,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT375SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,375.0,346.9,1.94,,,72.0,9.93,48.1,9.33,40.2,0.0047167500000000005,-0.1315054,46.4,1.8192972617169314,9.939616468008808,3.211337811028411e-11,0.24271889136352554,250.63241481908045,9.184475521302742,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jetion Solar (China) CoLtd JT380SAh(1500),Jetion Solar (China) CoLtd,Mono-c-Si,0,380.0,351.7,1.94,,,72.0,9.99,48.4,9.39,40.5,0.00474525,-0.1323256,46.4,1.8314469338163177,9.999253126859056,3.269502427397784e-11,0.23677579550718544,255.63144817883304,9.288606570746001,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS380,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,380.0,357.0,1.9,,,54.0,12.75,36.2,12.55,30.3,0.0036975000000000003,-0.08470800000000002,46.0,1.2442122095509067,12.750000958786487,2.950085975008116e-12,0.07475794615454683,994017.8469118574,3.162974626512507,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D385,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,385.0,362.3,1.9,,,54.0,12.81,36.5,12.61,30.6,0.003971100000000001,-0.08541,45.7,1.256960502922642,12.81000072980296,3.135978328516446e-12,0.053232730989273426,934379.7738983921,3.614994236577512,-0.297,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS385,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,385.0,361.8,1.9,,,54.0,12.81,36.5,12.61,30.6,0.0037149000000000006,-0.08541,46.0,1.2553660496690133,12.810000860507007,3.022425175004655e-12,0.06691815636881411,996063.8179451063,3.3292714197136384,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D390,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,390.0,367.1,1.9,,,54.0,12.87,36.7,12.67,30.8,0.0039897,-0.08587800000000001,45.7,1.2641284335473708,12.870071287212914,3.170728885424296e-12,0.15195655391051682,27433.827355465448,3.6696429747788106,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS390,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,390.0,366.7,1.9,,,54.0,12.87,36.7,12.67,30.8,0.0037322999999999996,-0.08587800000000001,46.0,1.262848604348866,12.870000651210908,3.0790923783915036e-12,0.050582676525617105,999677.7645467551,3.4477841385538857,-0.298,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D395,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,395.0,371.9,1.9,,,54.0,12.93,36.9,12.73,31.0,0.0040083,-0.086346,45.7,1.2718291536693611,12.930000698648353,3.245396947276962e-12,0.053926674963512104,997911.5782546797,3.8285380540131086,-0.297,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS395,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,395.0,371.5,1.9,,,54.0,12.93,36.9,12.73,31.0,0.0037497000000000003,-0.086346,46.0,1.270265880260088,12.93000072124554,3.13156206369132e-12,0.05567434721118674,997973.5261150162,3.5522699697390796,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D400,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,400.0,376.7,1.9,,,54.0,12.99,37.2,12.79,31.3,0.004026900000000001,-0.08704800000000001,45.7,1.2830146771892363,12.990000586281102,3.3233914287121124e-12,0.045131825660430946,999850.0521527688,3.9922739976392347,-0.297,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS400,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,400.0,376.3,1.9,,,54.0,12.99,37.2,12.79,31.3,0.0037671000000000007,-0.08704800000000001,46.0,1.2814254145995956,12.990000611104433,3.2060071309959693e-12,0.04704571258572388,999913.5665917955,3.7134028004525566,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D405,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,405.0,381.5,1.9,,,54.0,13.05,37.4,12.85,31.5,0.0040455000000000005,-0.08751600000000001,45.7,1.2904831110451045,13.050000582275949,3.381812007439215e-12,0.03952260769174681,885372.7017540503,4.102170110913094,-0.297,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS405,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,405.0,381.1,1.9,,,54.0,13.05,37.4,12.85,31.5,0.0037845000000000005,-0.08751600000000001,46.0,1.2888791674466336,13.050000534301963,3.262018505665761e-12,0.04089447651004603,998825.800489225,3.822097580270436,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D410,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,410.0,386.3,1.9,,,54.0,13.11,37.7,12.91,31.8,0.0040641,-0.08821800000000002,45.7,1.3016448217602334,13.110000521244112,3.459205784308452e-12,0.03526229138703922,886477.1708976451,4.257007992483743,-0.297,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54TS410,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,410.0,385.9,1.9,,,54.0,13.11,37.7,12.91,31.8,0.0038019,-0.08821800000000002,46.0,1.300029217965345,13.110000528854293,3.33690917218799e-12,0.035785841521546236,886658.0525679627,3.977133748216193,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-54TS415,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,415.0,393.6,1.9,,,18.0,13.5,38.28,12.79,32.48,0.00459,-0.0830676,45.94,1.2641471540328404,13.510639898444344,9.382412733406005e-13,0.13277043175642178,168.46033246333855,0.6751195146367358,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-54D415,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,415.0,391.2,1.9,,,54.0,13.17,37.9,12.97,32.0,0.004082700000000001,-0.088686,45.7,1.3090988589372563,13.170000478431719,3.5174853625482705e-12,0.03223408975794537,886901.5038968002,4.361323523834528,-0.297,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-54TS420,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,420.0,398.4,1.9,,,18.0,13.57,38.42,12.89,32.61,0.004613800000000001,-0.08337140000000001,45.94,1.2675343267654817,13.578663050500857,9.184190770665259e-13,0.13173942987300685,206.35965465025964,0.43768542478712114,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-54TS425,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,425.0,403.3,1.9,,,18.0,13.64,38.56,12.99,32.74,0.004637600000000001,-0.0836752,45.94,1.270937949627881,13.64671271087065,8.994493270567181e-13,0.13071864837786684,265.61584422331106,0.20510208602060598,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS425,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,425.0,394.8,2.1,,,60.0,12.7,40.9,12.5,34.1,0.005207000000000001,-0.11452000000000001,45.7,1.5446053112709217,12.700000442927665,4.017975137167407e-11,0.031039322988468013,889567.8849389108,6.421485368704546,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-54TS430,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,430.0,408.1,1.9,,,18.0,13.71,38.7,13.1,32.86,0.0046614000000000004,-0.083979,45.94,1.2737755674200248,13.71422290379816,8.69931434768589e-13,0.13060867422163258,424.0316643174166,-0.13591218825585039,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D430,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,430.0,399.3,2.1,,,60.0,12.76,41.1,12.56,34.3,0.0049764,-0.11508000000000002,45.9,1.549360011674744,12.760000411707031,3.848431891798748e-11,0.028738025831546922,890250.9831953886,6.037180461620619,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS430,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,430.0,399.6,2.1,,,60.0,12.76,41.1,12.56,34.3,0.0052315999999999994,-0.11508000000000002,45.7,1.552872707051263,12.760000395234975,4.086429816339992e-11,0.027575709273325064,889850.3872772387,6.526175458171813,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-54TS435,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,435.0,413.0,1.9,,,18.0,13.78,38.84,13.19,32.99,0.0046852000000000005,-0.0842828,45.94,1.2776238959576136,13.782893739758784,8.604399796807064e-13,0.1295599185154312,616.9648378498248,-0.2797398652883022,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D435,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,435.0,404.1,2.1,,,60.0,12.82,41.3,12.62,34.5,0.0049998,-0.11564,45.9,1.5576074775300564,12.820000364132323,3.913431692399119e-11,0.025306255793058792,890530.6837534934,6.140424262719293,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS435,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,435.0,404.4,2.1,,,60.0,12.82,41.3,12.62,34.5,0.005256200000000001,-0.11564,45.7,1.5611401058541954,12.82000034753211,4.155422969199117e-11,0.024141587519922132,890129.0539712526,6.6298525780489035,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-54TS440,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,440.0,417.8,1.9,,,18.0,13.85,38.98,13.29,33.11,0.0047090000000000005,-0.0845866,45.94,1.2796340269399233,13.850003871938124,8.166587304411381e-13,0.1296140292524078,463632.27102181496,-0.7794780370279519,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D440,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,440.0,408.8,2.1,,,60.0,12.88,41.5,12.68,34.7,0.0050232,-0.11620000000000003,45.9,1.565854956728249,12.880000316547148,3.978937638852745e-11,0.02190355971913883,890806.6013974929,6.24267537609838,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS440,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,440.0,409.1,2.1,,,60.0,12.88,41.5,12.68,34.7,0.0052808,-0.11620000000000003,45.7,1.5694069936094588,12.88000026722535,4.224917213860994e-11,0.020739293072329613,999642.8552070387,6.73245895741618,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D445,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,445.0,413.6,2.1,,,60.0,12.94,41.7,12.74,34.9,0.005046599999999999,-0.11676000000000002,45.9,1.5741019396559446,12.94000023989723,4.044914331781876e-11,0.018532271208751436,999653.9977510967,6.343876657121473,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS445,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,445.0,413.9,2.1,,,60.0,12.94,41.7,12.74,34.9,0.0053054,-0.11676000000000002,45.7,1.5776743943603013,12.940000224762626,4.294979303031943e-11,0.017362969933902676,999647.4542383553,6.834153534297536,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D450,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,450.0,418.4,2.1,,,60.0,13.0,42.0,12.8,35.2,0.00507,-0.11760000000000001,45.9,1.5858292865070347,13.000092184328661,4.090537265249845e-11,0.15233173776620904,21482.12333703753,6.400973314768759,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS450,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,450.0,418.7,2.1,,,60.0,13.0,42.0,12.8,35.2,0.0053300000000000005,-0.11760000000000001,45.7,1.5900484598792304,13.000000164842957,4.388962529428849e-11,0.012675560478689266,999660.9496736685,6.981002796519733,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS455,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,455.0,424.0,1.9,,,20.0,13.43,42.26,12.69,35.86,0.0044319,-0.1018466,45.08,1.6112839150860487,13.436262554823351,5.393695915369977e-11,0.1083343200737247,232.32210783021307,26.319056979680788,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D455,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,455.0,423.2,2.1,,,60.0,13.06,42.2,12.86,35.4,0.0050934,-0.11816000000000003,45.9,1.5946942044960961,13.060000137665144,4.200624478113062e-11,0.010537204318960752,999669.6428355154,6.589084369143116,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60TS455,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,455.0,423.5,2.1,,,60.0,13.06,42.2,12.86,35.4,0.0053546,-0.11816000000000003,45.7,1.5983164410026405,13.060000136217287,4.460250378696091e-11,0.009357610859364653,872061.2578200754,7.080396494566847,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS460,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,460.0,428.8,1.9,,,20.0,13.5,42.41,12.79,35.99,0.004455000000000001,-0.1022081,45.08,1.614951879128505,13.504821763830622,5.2605096538287085e-11,0.10830248619344333,303.22588143467124,25.997832265751835,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-60D460,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,460.0,428.0,2.1,,,60.0,13.12,42.4,12.92,35.6,0.0051167999999999995,-0.11872,45.9,1.6029423047433515,13.120000105928519,4.2682874650312246e-11,0.007249043295784641,872616.9953183606,6.68713697017066,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS465,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,465.0,433.7,1.9,,,20.0,13.57,42.56,12.88,36.13,0.0044781000000000005,-0.10256960000000001,45.08,1.619486322381939,13.57379196796967,5.198846723854881e-11,0.1072596729798181,383.84126762205653,25.815956464696978,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS470,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,470.0,438.5,1.9,,,20.0,13.64,42.71,12.97,36.26,0.004501200000000001,-0.10293110000000001,45.08,1.6238103193021385,13.642791111384003,5.1208245258678194e-11,0.10711169410280022,523.4486717533357,25.600857972572843,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS475,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,475.0,443.3,1.9,,,20.0,13.71,42.86,13.05,36.4,0.0045243,-0.1032926,45.08,1.6289779016553645,13.712215691515405,5.1088180929537716e-11,0.10597387471340276,655.7329220594062,25.51987312170018,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS480,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,480.0,448.2,1.9,,,20.0,13.78,43.01,13.14,36.54,0.0045474,-0.1036541,45.08,1.633546472669656,13.78122572606912,5.052471515589893e-11,0.10495714167449803,1179.9614488999905,25.346762310965953,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS485,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,485.0,453.0,1.9,,,20.0,13.85,43.16,13.23,36.68,0.004570500000000001,-0.10401559999999999,45.08,1.6381271721603818,13.850252428859111,4.9979717121923556e-11,0.1039505528364668,5703.4460286113435,25.176692782538858,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-60TS490,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,490.0,457.8,1.9,,,20.0,13.92,43.31,13.32,36.8,0.0045936,-0.1043771,45.08,1.6442229503932382,13.920001400655797,5.058396892213673e-11,0.10061688673346651,999999.9311534449,25.244619728080032,-0.378,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS510,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,510.0,478.1,2.52,,,72.0,12.88,48.6,12.53,40.7,0.0072128,-0.12490200000000001,45.7,1.7590001743081807,12.880001601595795,1.2901725666908988e-11,0.12432009001301379,999791.4766997184,5.478898532370705,-0.314,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D515,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,515.0,483.0,2.52,,,72.0,12.95,48.8,12.6,40.9,0.007381500000000001,-0.125416,45.7,1.7668059547209007,12.950001562573783,1.3087393079864811e-11,0.12063562690871851,999792.7074888566,5.54167589509482,-0.313,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS515,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,515.0,482.9,2.52,,,72.0,12.95,48.8,12.6,40.9,0.007252000000000001,-0.125416,45.7,1.7669458978569776,12.950001562054519,1.3116053830743932e-11,0.12059552063323929,999792.5855935467,5.574127301857967,-0.314,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D520,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,520.0,487.8,2.52,,,72.0,13.02,48.9,12.67,41.1,0.007421400000000001,-0.125673,45.7,1.7726432352929935,13.020001428060636,1.3620567819094516e-11,0.10965850122289328,999796.8037583899,5.839664681303215,-0.313,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS520,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,520.0,487.7,2.52,,,72.0,13.02,48.9,12.67,41.1,0.007291200000000001,-0.125673,45.7,1.7727834897949182,13.020001427539576,1.3650326785387902e-11,0.10961846810510514,999796.6289390011,5.872094093620052,-0.314,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D525,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,525.0,492.6,2.52,,,72.0,13.09,49.1,12.74,41.2,0.0074613,-0.12618700000000002,45.7,1.778782543112321,13.090001498010734,1.3459925911172281e-11,0.1144138643489501,999789.3485524451,5.690958048034482,-0.313,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS525,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,525.0,492.5,2.52,,,72.0,13.09,49.1,12.74,41.2,0.0073304,-0.12618700000000002,45.7,1.7789228674790218,13.090001497488652,1.3489265239382317e-11,0.11437397229958925,999789.2237405656,5.72333266186817,-0.314,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D530,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,530.0,497.5,2.52,,,72.0,13.16,49.2,12.82,41.4,0.0075012,-0.12644400000000003,45.7,1.779829859361745,13.160004218004662,1.3002021545257994e-11,0.17568422926960348,548132.0292560693,5.346854660590201,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS530,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,530.0,497.3,2.52,,,72.0,13.16,49.2,12.82,41.4,0.0073696,-0.12644400000000003,45.7,1.779583741008098,13.160004219033741,1.2952408811800482e-11,0.1757268083251863,548131.1307791786,5.327595408728289,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D535,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,535.0,502.3,2.52,,,72.0,13.23,49.4,12.9,41.5,0.0075411,-0.12695800000000002,45.7,1.792020761129181,13.23000131832777,1.4109658245725861e-11,0.0996251616074247,999793.9622040909,6.006308449669707,-0.313,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS535,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,535.0,502.2,2.52,,,72.0,13.23,49.4,12.9,41.5,0.0074088,-0.12695800000000002,45.7,1.7921579390840177,13.230001317808608,1.4139461707554054e-11,0.09958590880221507,999793.7805971093,6.038123500749408,-0.314,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D540,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,540.0,507.1,2.52,,,72.0,13.3,49.5,12.97,41.7,0.007581000000000001,-0.127215,45.7,1.7885498627875616,13.300004178549427,1.2714283934167564e-11,0.17121229012829967,544959.7571024676,5.063663295693989,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS540,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,540.0,507.0,2.52,,,72.0,13.3,49.5,12.97,41.7,0.007448000000000001,-0.127215,45.7,1.7883124661351597,13.30000417954727,1.266765777050177e-11,0.17125292633145617,544958.9493668925,5.045786224285901,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D545,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,545.0,511.9,2.52,,,72.0,13.37,49.7,13.04,41.8,0.007620899999999999,-0.127729,45.7,1.7955918052926507,13.37000434158377,1.2744902096381282e-11,0.17678313541210677,544411.8053838392,5.039259463231376,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS545,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,545.0,511.8,2.52,,,72.0,13.37,49.7,13.04,41.8,0.007487199999999999,-0.127729,45.7,1.8036711574451403,13.370001464015829,1.4427251891527232e-11,0.10949864024959977,999999.395931373,6.1213988855330745,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D550,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,550.0,521.4,2.52,,,24.0,13.8,51.58,12.57,43.81,0.004830000000000001,-0.1139918,45.76,1.7477818508991418,13.838178958455034,1.9779350000006473e-12,0.16457802234262642,59.48765499501358,5.189578472035199,-0.268,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D550,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,550.0,516.7,2.52,,,72.0,13.44,49.8,13.11,42.0,0.0076608,-0.12798600000000002,45.7,1.7965837252934385,13.440004150224489,1.230460994564439e-11,0.16697670110294477,540737.8367399621,4.693328080172461,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72TS550,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,550.0,516.6,2.52,,,72.0,13.44,49.8,13.11,42.0,0.0075264,-0.12798600000000002,45.7,1.7963275550750306,13.440004151310369,1.2256066037764422e-11,0.16702014870606263,540737.0431375952,4.673195603681921,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D555,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,555.0,526.3,2.52,,,24.0,13.86,51.73,12.64,43.95,0.004851,-0.1143233,45.76,1.7520794637127697,13.897269417554906,1.9631962344906872e-12,0.16337416700075855,60.75667674728595,5.080588433046794,-0.268,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-PM10-72D555,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,555.0,521.5,2.52,,,72.0,13.51,50.0,13.18,42.1,0.0077007,-0.1285,45.7,1.8035579737707979,13.510004314321101,1.2322977922625987e-11,0.17252014250009354,540239.0443070474,4.661653714346202,-0.313,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D560,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,560.0,531.1,2.52,,,24.0,13.92,51.88,12.72,44.09,0.0048720000000000005,-0.11465480000000002,45.76,1.7557236513606955,13.955841953383695,1.9291075932992064e-12,0.16228596993979563,63.0272763791403,4.8805213523987465,-0.268,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D565,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,565.0,536.0,2.52,,,24.0,13.98,52.03,12.79,44.23,0.004893000000000001,-0.1149863,45.76,1.7600382118473692,14.014955655601032,1.9154295210269774e-12,0.16110295582988746,64.43075616337813,4.77538711604347,-0.268,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D570,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,570.0,540.8,2.52,,,24.0,14.04,52.18,12.86,44.37,0.004914,-0.11531780000000001,45.76,1.7643590503328221,14.074079308924915,1.902105922062056e-12,0.15993067663920418,65.88826976873374,4.671719935659906,-0.268,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D575,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,575.0,545.7,2.52,,,24.0,14.1,52.33,12.92,44.51,0.004935,-0.1156493,45.76,1.769335415009495,14.133732365044583,1.9080162990063744e-12,0.15866705250696556,66.32222311452871,4.659851870471937,-0.268,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D580,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,580.0,550.5,2.52,,,24.0,14.16,52.48,13.01,44.65,0.004956,-0.11598079999999998,45.76,1.7723753250190324,14.191838585007535,1.85808770760268e-12,0.15771799135552392,70.1440330151292,4.3793372796369,-0.268,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D585,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,585.0,555.4,2.52,,,24.0,14.22,52.63,13.08,44.79,0.004977000000000001,-0.1163123,45.76,1.776717823389324,14.250994356080634,1.8460220897090834e-12,0.1565762682818757,71.83612814886659,4.280637486170874,-0.268,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Green Energy Power Technology Co Ltd GEO-NM10-72D590,Jiangsu Green Energy Power Technology Co Ltd,Mono-c-Si,1,590.0,560.2,2.52,,,24.0,14.28,52.78,13.15,44.93,0.004998000000000001,-0.1166438,45.76,1.7810661110331056,14.310159661256588,1.834262602320924e-12,0.1554447771043489,73.60001159178688,4.183285552823236,-0.268,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-390,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,390.0,363.7,1.69,,,54.0,13.61,36.85,12.73,30.64,0.0076367071,-0.11324005000000001,43.7,1.4739278922972021,13.624695393188418,1.8492231556555188e-10,0.13575738197572165,125.73042470736434,8.872487354443196,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-390,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,390.0,366.9,1.95,,,54.0,13.61,36.85,12.73,30.64,0.0056093615,-0.09240506,43.2,1.3466959772493088,13.630703508030098,1.735104612910227e-11,0.1576803680833081,103.6553715258437,10.569477330216975,-0.33735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-390,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,390.0,366.9,1.95,,,54.0,13.61,36.85,12.73,30.64,0.0056093615,-0.09240506,43.2,1.3466959772493088,13.630703508030098,1.735104612910227e-11,0.1576803680833081,103.6553715258437,10.569477330216975,-0.33735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-390,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,390.0,366.9,1.95,,,54.0,13.61,36.85,12.73,30.64,0.0056093615,-0.09240506,43.2,1.3466959772493088,13.630703508030098,1.735104612910227e-11,0.1576803680833081,103.6553715258437,10.569477330216975,-0.33735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-WH108P8-390,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,390.0,363.0,1.69,,,54.0,13.61,36.85,12.73,30.64,0.009682153999999998,-0.109772465,44.0,1.4951230397581396,13.623802543266345,2.6376720754471607e-10,0.1321761930874453,130.33236519994063,15.419955651027324,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-395,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,395.0,368.5,1.69,,,54.0,13.7,36.98,12.81,30.84,0.007687206999999999,-0.11363954,43.7,1.4818235359628038,13.714286664286782,1.946732145942045e-10,0.12695010270679455,121.73705675124035,9.26906464539569,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-395,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,395.0,371.7,1.95,,,54.0,13.7,36.98,12.81,30.84,0.005646455,-0.09273104799999998,43.2,1.3536826566878486,13.720203651594144,1.8261028292066814e-11,0.14894135490430221,100.99642433604537,10.972799707880492,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-395,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,395.0,371.7,1.95,,,54.0,13.7,36.98,12.81,30.84,0.005646455,-0.09273104799999998,43.2,1.3536826566878486,13.720203651594144,1.8261028292066814e-11,0.14894135490430221,100.99642433604537,10.972799707880492,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-395,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,395.0,371.7,1.95,,,54.0,13.7,36.98,12.81,30.84,0.005646455,-0.09273104799999998,43.2,1.3536826566878486,13.720203651594144,1.8261028292066814e-11,0.14894135490430221,100.99642433604537,10.972799707880492,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH108P8-395,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,395.0,367.8,1.69,,,54.0,13.7,36.98,12.81,30.84,0.009746179999999998,-0.11015972199999999,44.0,1.5031136569358747,13.713411992938367,2.774108098560886e-10,0.12336726996075226,126.01644515519645,15.832695054163471,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-400,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,400.0,373.3,1.69,,,54.0,13.79,37.07,12.9,31.01,0.0077377068999999995,-0.11391611000000001,43.7,1.4875879625724984,13.803224117517166,2.032231166166415e-10,0.11791052984649021,122.95612582031131,9.590111437680722,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-400,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,400.0,376.5,1.95,,,54.0,13.79,37.07,12.9,31.01,0.0056835485,-0.092956732,43.2,1.3587655616854701,13.808938414485008,1.9058573262352645e-11,0.13991114227322254,101.87625053550128,11.29864563046683,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-400,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,400.0,376.5,1.95,,,54.0,13.79,37.07,12.9,31.01,0.0056835485,-0.092956732,43.2,1.3587655616854701,13.808938414485008,1.9058573262352645e-11,0.13991114227322254,101.87625053550128,11.29864563046683,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-400,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,400.0,376.5,1.95,,,54.0,13.79,37.07,12.9,31.01,0.0056835485,-0.092956732,43.2,1.3587655616854701,13.808938414485008,1.9058573262352645e-11,0.13991114227322254,101.87625053550128,11.29864563046683,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH108P8-400,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,400.0,372.7,1.69,,,54.0,13.79,37.07,12.9,31.01,0.009810205999999998,-0.11042782300000001,44.0,1.5089455285205424,13.802385151587961,2.8937250352930926e-10,0.11433383901320761,127.30273801004094,16.166981489533534,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,383.7,1.95,,,108.0,13.83,37.54,13.09,30.94,0.0045343038,-0.08592906,43.2,1.2883834145813844,13.843315428462077,3.02836844996184e-12,0.19455671886416923,202.07531690716735,4.990887202746967,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,383.7,1.95,,,108.0,13.83,37.54,13.09,30.94,0.0045343038,-0.08592906,43.2,1.2883834145813844,13.843315428462077,3.02836844996184e-12,0.19455671886416923,202.07531690716735,4.990887202746967,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,383.7,1.95,,,108.0,13.83,37.54,13.09,30.94,0.0045343038,-0.08592906,43.2,1.2883834145813844,13.843315428462077,3.02836844996184e-12,0.19455671886416923,202.07531690716735,4.990887202746967,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,383.7,1.95,,,108.0,13.83,37.54,13.09,30.94,0.0045343038,-0.08592906,43.2,1.2883834145813844,13.843315428462077,3.02836844996184e-12,0.19455671886416923,202.07531690716735,4.990887202746967,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,378.2,1.69,,,54.0,13.87,37.23,12.98,31.21,0.0077825957,-0.11440779,43.7,1.4954413002362947,13.882452858894048,2.0939537024950536e-10,0.11185369427635515,124.58270035983557,9.80294278050202,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,381.4,1.95,,,54.0,13.87,37.23,12.98,31.21,0.0057165205,-0.09335794799999998,43.2,1.3658174457095824,13.88802168335222,1.9634466280649264e-11,0.133886455622896,103.04282401176384,11.51459567206862,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,381.4,1.95,,,54.0,13.87,37.23,12.98,31.21,0.0057165205,-0.09335794799999998,43.2,1.3658174457095824,13.88802168335222,1.9634466280649264e-11,0.133886455622896,103.04282401176384,11.51459567206862,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,381.4,1.95,,,54.0,13.87,37.23,12.98,31.21,0.0057165205,-0.09335794799999998,43.2,1.3658174457095824,13.88802168335222,1.9634466280649264e-11,0.133886455622896,103.04282401176384,11.51459567206862,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH108P8-405,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,405.0,377.5,1.69,,,54.0,13.87,37.23,12.98,31.21,0.009867118,-0.11090444699999999,44.0,1.5169009468610368,13.881639424750409,2.980083700148385e-10,0.10827690755102956,129.0270614542687,16.388550388913043,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,388.5,1.95,,,108.0,13.91,37.73,13.17,31.13,0.0045605326,-0.08636396999999998,43.2,1.2953653960514864,13.922889230749654,3.078495736809631e-12,0.19152600530739053,206.6940060208339,5.08216771038259,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,388.5,1.95,,,108.0,13.91,37.73,13.17,31.13,0.0045605326,-0.08636396999999998,43.2,1.2953653960514864,13.922889230749654,3.078495736809631e-12,0.19152600530739053,206.6940060208339,5.08216771038259,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,388.5,1.95,,,108.0,13.91,37.73,13.17,31.13,0.0045605326,-0.08636396999999998,43.2,1.2953653960514864,13.922889230749654,3.078495736809631e-12,0.19152600530739053,206.6940060208339,5.08216771038259,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,388.5,1.95,,,108.0,13.91,37.73,13.17,31.13,0.0045605326,-0.08636396999999998,43.2,1.2953653960514864,13.922889230749654,3.078495736809631e-12,0.19152600530739053,206.6940060208339,5.08216771038259,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,383.0,1.69,,,54.0,13.95,37.32,13.04,31.45,0.007827484499999999,-0.11468436000000001,43.7,1.504321628317669,13.961751367791834,2.2934913068910803e-10,0.0966529438808125,114.7363123326904,10.567460388962498,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,386.2,1.95,,,54.0,13.95,37.32,13.04,31.45,0.0057494925,-0.093583632,43.2,1.3734895320893745,13.967209125122446,2.1497725626873688e-11,0.11887784424675087,96.36433698896876,12.293048881739747,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,386.2,1.95,,,54.0,13.95,37.32,13.04,31.45,0.0057494925,-0.093583632,43.2,1.3734895320893745,13.967209125122446,2.1497725626873688e-11,0.11887784424675087,96.36433698896876,12.293048881739747,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,386.2,1.95,,,54.0,13.95,37.32,13.04,31.45,0.0057494925,-0.093583632,43.2,1.3734895320893745,13.967209125122446,2.1497725626873688e-11,0.11887784424675087,96.36433698896876,12.293048881739747,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH108P8-410,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,410.0,382.3,1.69,,,54.0,13.95,37.32,13.04,31.45,0.009924029999999999,-0.11117254800000001,44.0,1.5258647078826855,13.960961520325869,3.2577087313237866e-10,0.09306440226539443,118.43689787292111,17.18288909949589,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,393.4,1.95,,,108.0,13.99,37.92,13.25,31.32,0.0045867614,-0.08679888000000001,43.2,1.3023468280131327,14.00247240233131,3.128953474167454e-12,0.18853245223579992,211.47241253740697,5.17242583682906,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,393.4,1.95,,,108.0,13.99,37.92,13.25,31.32,0.0045867614,-0.08679888000000001,43.2,1.3023468280131327,14.00247240233131,3.128953474167454e-12,0.18853245223579992,211.47241253740697,5.17242583682906,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,393.4,1.95,,,108.0,13.99,37.92,13.25,31.32,0.0045867614,-0.08679888000000001,43.2,1.3023468280131327,14.00247240233131,3.128953474167454e-12,0.18853245223579992,211.47241253740697,5.17242583682906,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,393.4,1.95,,,108.0,13.99,37.92,13.25,31.32,0.0045867614,-0.08679888000000001,43.2,1.3023468280131327,14.00247240233131,3.128953474167454e-12,0.18853245223579992,211.47241253740697,5.17242583682906,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,387.8,1.69,,,54.0,14.02,37.45,13.13,31.61,0.0078667622,-0.11508385000000003,43.7,1.5093691139015812,14.030263263768651,2.3024697199651663e-10,0.09231303520042683,126.10304305629097,10.55078420202246,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,391.0,1.95,,,54.0,14.02,37.45,13.13,31.61,0.005778343,-0.09390962000000001,43.2,1.3781099242291253,14.03539344772469,2.1580223736871002e-11,0.11447327778128875,104.25964268790338,12.274257576471108,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,391.0,1.95,,,54.0,14.02,37.45,13.13,31.61,0.005778343,-0.09390962000000001,43.2,1.3781099242291253,14.03539344772469,2.1580223736871002e-11,0.11447327778128875,104.25964268790338,12.274257576471108,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,391.0,1.95,,,54.0,14.02,37.45,13.13,31.61,0.005778343,-0.09390962000000001,43.2,1.3781099242291253,14.03539344772469,2.1580223736871002e-11,0.11447327778128875,104.25964268790338,12.274257576471108,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH108P8-415,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,415.0,387.1,1.69,,,54.0,14.02,37.45,13.13,31.61,0.009973827999999999,-0.11155980500000001,44.0,1.530986983157635,14.02952654383378,3.270744497903931e-10,0.0887341779197542,130.58809676312598,17.16631595830447,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,398.2,1.95,,,108.0,14.07,38.11,13.33,31.51,0.004612990200000001,-0.08723378999999999,43.2,1.3093277203676057,14.082064773395457,3.179739220149234e-12,0.18557537938956248,216.4189501914832,5.261679441811168,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,398.2,1.95,,,108.0,14.07,38.11,13.33,31.51,0.004612990200000001,-0.08723378999999999,43.2,1.3093277203676057,14.082064773395457,3.179739220149234e-12,0.18557537938956248,216.4189501914832,5.261679441811168,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,398.2,1.95,,,108.0,14.07,38.11,13.33,31.51,0.004612990200000001,-0.08723378999999999,43.2,1.3093277203676057,14.082064773395457,3.179739220149234e-12,0.18557537938956248,216.4189501914832,5.261679441811168,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,398.2,1.95,,,108.0,14.07,38.11,13.33,31.51,0.004612990200000001,-0.08723378999999999,43.2,1.3093277203676057,14.082064773395457,3.179739220149234e-12,0.18557537938956248,216.4189501914832,5.261679441811168,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,395.8,1.95,,,54.0,14.09,37.58,13.22,31.77,0.0058071935,-0.09423560799999998,43.2,1.3827347236271341,14.103676741043248,2.1664290796363815e-11,0.11012836888233508,113.45602858273172,12.256269789846808,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,395.8,1.95,,,54.0,14.09,37.58,13.22,31.77,0.0058071935,-0.09423560799999998,43.2,1.3827347236271341,14.103676741043248,2.1664290796363815e-11,0.11012836888233508,113.45602858273172,12.256269789846808,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,395.8,1.95,,,54.0,14.09,37.58,13.22,31.77,0.0058071935,-0.09423560799999998,43.2,1.3827347236271341,14.103676741043248,2.1664290796363815e-11,0.11012836888233508,113.45602858273172,12.256269789846808,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-420,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,420.0,395.8,1.95,,,54.0,14.09,37.58,13.22,31.77,0.0058071935,-0.09423560799999998,43.2,1.3827347236271341,14.103676741043248,2.1664290796363815e-11,0.11012836888233508,113.45602858273172,12.256269789846808,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,403.1,1.95,,,108.0,14.15,38.3,13.31,31.7,0.004639219000000001,-0.0876687,43.2,1.320668930048364,14.17046989499761,3.5257153135008007e-12,0.18262052139713994,126.23808680549057,6.148557013482646,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,403.1,1.95,,,108.0,14.15,38.3,13.31,31.7,0.004639219000000001,-0.0876687,43.2,1.320668930048364,14.17046989499761,3.5257153135008007e-12,0.18262052139713994,126.23808680549057,6.148557013482646,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,403.1,1.95,,,108.0,14.15,38.3,13.31,31.7,0.004639219000000001,-0.0876687,43.2,1.320668930048364,14.17046989499761,3.5257153135008007e-12,0.18262052139713994,126.23808680549057,6.148557013482646,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,403.1,1.95,,,108.0,14.15,38.3,13.31,31.7,0.004639219000000001,-0.0876687,43.2,1.320668930048364,14.17046989499761,3.5257153135008007e-12,0.18262052139713994,126.23808680549057,6.148557013482646,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,400.7,1.95,,,54.0,14.16,37.72,13.31,31.94,0.005836044,-0.09458667199999998,43.2,1.3877648885104485,14.172043724400988,2.1763927607296176e-11,0.10573818336299175,124.31807903964129,12.244955324590958,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8B-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,400.7,1.95,,,54.0,14.16,37.72,13.31,31.94,0.005836044,-0.09458667199999998,43.2,1.3877648885104485,14.172043724400988,2.1763927607296176e-11,0.10573818336299175,124.31807903964129,12.244955324590958,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8b-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,400.7,1.95,,,54.0,14.16,37.72,13.31,31.94,0.005836044,-0.09458667199999998,43.2,1.3877648885104485,14.172043724400988,2.1763927607296176e-11,0.10573818336299175,124.31807903964129,12.244955324590958,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108P8T-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,400.7,1.95,,,54.0,14.16,37.72,13.31,31.94,0.005836044,-0.09458667199999998,43.2,1.3877648885104485,14.172043724400988,2.1763927607296176e-11,0.10573818336299175,124.31807903964129,12.244955324590958,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,402.5,2.0,,,48.0,15.67,34.56,14.79,28.74,0.00523378,-0.08111232,43.1,1.2040333457842722,15.686675083161061,5.275116171507727e-12,0.13662998566762868,128.39467474097037,6.081954609575348,-0.3102,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-425,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,425.0,402.5,2.0,,,48.0,15.67,34.56,14.79,28.74,0.00523378,-0.08111232,43.1,1.2040333457842722,15.686675083161061,5.275116171507727e-12,0.13662998566762868,128.39467474097037,6.081954609575348,-0.3102,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-430,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,430.0,407.9,1.95,,,108.0,14.23,38.49,13.49,31.88,0.004665447800000001,-0.08810361,43.2,2.7013127611101284,14.2305977879176,2.770177179789193e-09,1.9666893422713403,54840.0448198709,97.31898287616927,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-430,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,430.0,407.9,1.95,,,108.0,14.23,38.49,13.49,31.88,0.004665447800000001,-0.08810361,43.2,2.7013127611101284,14.2305977879176,2.770177179789193e-09,1.9666893422713403,54840.0448198709,97.31898287616927,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-430,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,430.0,407.9,1.95,,,108.0,14.23,38.49,13.49,31.88,0.004665447800000001,-0.08810361,43.2,2.7013127611101284,14.2305977879176,2.770177179789193e-09,1.9666893422713403,54840.0448198709,97.31898287616927,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-430,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,430.0,407.9,1.95,,,108.0,14.23,38.49,13.49,31.88,0.004665447800000001,-0.08810361,43.2,2.7013127611101284,14.2305977879176,2.770177179789193e-09,1.9666893422713403,54840.0448198709,97.31898287616927,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-430,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,430.0,407.4,2.0,,,48.0,15.75,34.7,14.89,28.88,0.0052604999999999996,-0.08144090000000001,43.1,1.2084803681837397,15.764662433520897,5.257822190220031e-12,0.13471534704003413,144.7076787408197,6.001370122490516,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-430,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,430.0,407.4,2.0,,,48.0,15.75,34.7,14.89,28.88,0.0052604999999999996,-0.08144090000000001,43.1,1.2084803681837397,15.764662433520897,5.257822190220031e-12,0.13471534704003413,144.7076787408197,6.001370122490516,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,412.8,1.95,,,108.0,14.31,38.68,13.57,32.06,0.004691676600000001,-0.08853852000000001,43.2,1.319765739724759,14.31000491709365,2.6744435065643895e-12,0.18012789199501125,524219.95610974194,3.5672592382892367,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,412.8,1.95,,,108.0,14.31,38.68,13.57,32.06,0.004691676600000001,-0.08853852000000001,43.2,1.319765739724759,14.31000491709365,2.6744435065643895e-12,0.18012789199501125,524219.95610974194,3.5672592382892367,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8b-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,412.8,1.95,,,108.0,14.31,38.68,13.57,32.06,0.004691676600000001,-0.08853852000000001,43.2,1.319765739724759,14.31000491709365,2.6744435065643895e-12,0.18012789199501125,524219.95610974194,3.5672592382892367,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8T-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,412.8,1.95,,,108.0,14.31,38.68,13.57,32.06,0.004691676600000001,-0.08853852000000001,43.2,1.319765739724759,14.31000491709365,2.6744435065643895e-12,0.18012789199501125,524219.95610974194,3.5672592382892367,-0.30381,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH120P8-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,407.2,1.69,,,60.0,13.61,40.78,12.7,34.26,0.0076367071,-0.12531694000000002,43.7,1.6425345738594133,13.623463884006728,2.191683596079697e-10,0.11765439071132631,118.93123120265606,10.388417779301989,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,412.2,2.0,,,48.0,15.83,34.84,14.99,29.02,0.00528722,-0.08176948,43.1,1.212931835902056,15.842702789827134,5.241274887006353e-12,0.13282525395937658,165.52456607727194,5.922269936846474,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,412.2,2.0,,,48.0,15.83,34.84,14.99,29.02,0.00528722,-0.08176948,43.1,1.212931835902056,15.842702789827134,5.241274887006353e-12,0.13282525395937658,165.52456607727194,5.922269936846474,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH120P8-435,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,435.0,406.5,1.69,,,60.0,13.61,40.78,12.7,34.26,0.009682153999999998,-0.121479542,44.0,1.6660667986231497,13.622625702367218,3.114385219793188e-10,0.11363682571760353,122.49593826748338,16.996098106712523,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-440,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,440.0,418.1,1.95,,,54.0,13.88,39.16,13.25,33.21,0.0045804,-0.07694939999999999,43.1,1.340136184339528,13.883669002862526,2.8146480397546557e-12,0.124922128160839,472.58601381218887,21.59394602994417,-0.2993,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-440,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,440.0,418.1,1.95,,,54.0,13.88,39.16,13.25,33.21,0.0045804,-0.07694939999999999,43.1,1.340136184339528,13.883669002862526,2.8146480397546557e-12,0.124922128160839,472.58601381218887,21.59394602994417,-0.2993,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH120P8-440,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,440.0,412.0,1.69,,,60.0,13.7,40.91,12.79,34.41,0.007687206999999999,-0.12571643,43.7,1.6484341702195022,13.712881529710188,2.2293199569403382e-10,0.11361622724854786,120.83521062079504,10.479994662825662,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-440,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,440.0,417.0,2.0,,,48.0,15.91,34.98,15.09,29.16,0.00531394,-0.08209806,43.1,1.2173876354039048,15.920795099632388,5.225447484276067e-12,0.1309592450841387,193.00994569920746,5.844614938414841,-0.3102,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-440,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,440.0,417.0,2.0,,,48.0,15.91,34.98,15.09,29.16,0.00531394,-0.08209806,43.1,1.2173876354039048,15.920795099632388,5.225447484276067e-12,0.1309592450841387,193.00994569920746,5.844614938414841,-0.3102,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH120P8-440,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,440.0,411.3,1.69,,,60.0,13.7,40.91,12.79,34.41,0.009746179999999998,-0.12186679899999998,44.0,1.672045534745611,13.712059725282758,3.167167525687892e-10,0.10961054597727433,124.518967336651,17.09147209303594,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-445,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,445.0,423.0,1.95,,,54.0,13.96,39.35,13.33,33.39,0.0046068,-0.07732275000000001,43.1,1.3468161584836882,13.963471281398133,2.842572444638428e-12,0.1232283926282669,495.57156831045813,21.634088728298877,-0.2993,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-445,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,445.0,423.0,1.95,,,54.0,13.96,39.35,13.33,33.39,0.0046068,-0.07732275000000001,43.1,1.3468161584836882,13.963471281398133,2.842572444638428e-12,0.1232283926282669,495.57156831045813,21.634088728298877,-0.2993,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH120P8-445,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,445.0,416.9,1.69,,,60.0,13.79,41.04,12.87,34.58,0.0077377068999999995,-0.12611592,43.7,1.6555587672029728,13.802582834691002,2.307072382307512e-10,0.10770030796798942,118.03280610909464,10.729411443169944,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-445,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,445.0,421.9,2.0,,,48.0,15.99,35.12,15.19,29.3,0.0053406600000000005,-0.08242663999999998,43.1,1.2218476514333076,15.998938378410703,5.210313560917071e-12,0.12911687149625722,230.97912016770078,5.768366260291934,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-445,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,445.0,421.9,2.0,,,48.0,15.99,35.12,15.19,29.3,0.0053406600000000005,-0.08242663999999998,43.1,1.2218476514333076,15.998938378410703,5.210313560917071e-12,0.12911687149625722,230.97912016770078,5.768366260291934,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH120P8-445,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,445.0,416.2,1.69,,,60.0,13.79,41.04,12.87,34.58,0.009810205999999998,-0.12225405599999999,44.0,1.679255523011803,13.801766293694664,3.275515634066972e-10,0.10369983633300092,121.53536488848604,17.350511403650465,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8-450,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,450.0,427.8,1.95,,,54.0,14.0,39.79,13.55,33.22,0.004620000000000001,-0.07818735,43.1,1.2861734201366766,14.000004572907564,5.134223363522353e-13,0.18039196198058371,552272.0870653697,5.320079822525989,-0.2993,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH108N8B-450,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,450.0,427.8,1.95,,,54.0,14.0,39.79,13.55,33.22,0.004620000000000001,-0.07818735,43.1,1.2861734201366766,14.000004572907564,5.134223363522353e-13,0.18039196198058371,552272.0870653697,5.320079822525989,-0.2993,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH120P8-450,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,450.0,421.7,1.69,,,60.0,13.87,41.2,12.96,34.73,0.0077825957,-0.12660760000000001,43.7,1.661351766684242,13.881827400817839,2.300804622496025e-10,0.10632854740955383,124.69155449311744,10.648912572242162,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-450,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,450.0,426.7,2.0,,,48.0,16.07,35.26,15.29,29.44,0.005367380000000001,-0.08275521999999999,43.1,1.2263117977365645,16.077131630375735,5.1958511655077016e-12,0.12729769104622585,286.84519441744214,5.693491475238273,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-450,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,450.0,426.7,2.0,,,48.0,16.07,35.26,15.29,29.44,0.005367380000000001,-0.08275521999999999,43.1,1.2263117977365645,16.077131630375735,5.1958511655077016e-12,0.12729769104622585,286.84519441744214,5.693491475238273,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH120P8-450,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,450.0,421.0,1.69,,,60.0,13.87,41.2,12.96,34.73,0.009867118,-0.12273068000000001,44.0,1.6851378974369726,13.881036265734643,3.2673843015257397e-10,0.10234070682766726,128.61829294272667,17.26735928027958,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH120P8-455,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,455.0,426.6,1.69,,,60.0,13.95,41.36,13.04,34.9,0.007827484499999999,-0.12709928,43.7,1.6683687780494618,13.961352760825,2.3344852184020155e-10,0.10306331643076487,126.64173294834401,10.726110454308314,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-455,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,455.0,431.6,2.0,,,48.0,16.15,35.39,15.39,29.57,0.005394099999999999,-0.08306033,43.1,1.230400391828052,16.15537444994508,5.178200199004476e-12,0.12558726058054612,377.384521694254,5.613501796462027,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-455,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,455.0,431.6,2.0,,,48.0,16.15,35.39,15.39,29.57,0.005394099999999999,-0.08306033,43.1,1.230400391828052,16.15537444994508,5.178200199004476e-12,0.12558726058054612,377.384521694254,5.613501796462027,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH120P8-455,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,455.0,425.9,1.69,,,60.0,13.95,41.36,13.04,34.9,0.009924029999999999,-0.123207304,44.0,1.6922505592231158,13.96057590157427,3.314588565512247e-10,0.09908151911602145,130.69214352465787,17.347728014552818,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH120P8-460,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,460.0,431.5,1.69,,,60.0,14.02,41.54,13.13,35.04,0.0078667622,-0.12765242000000002,43.7,1.6736268152602956,14.030436730467573,2.282762942321053e-10,0.10435999586772891,140.1901861238091,10.47390657825954,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-460,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,460.0,436.5,2.0,,,48.0,16.23,35.52,15.49,29.7,0.00542082,-0.08336544,43.1,1.234493597432227,16.23366204610234,5.1612752729215085e-12,0.12389785068722801,549.1089068273933,5.534956269543456,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-460,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,460.0,436.5,2.0,,,48.0,16.23,35.52,15.49,29.7,0.00542082,-0.08336544,43.1,1.234493597432227,16.23366204610234,5.1612752729215085e-12,0.12389785068722801,549.1089068273933,5.534956269543456,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH120P8-460,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,460.0,430.7,1.69,,,60.0,14.02,41.54,13.13,35.04,0.009973827999999999,-0.12374350599999999,44.0,1.697602328469857,14.02969368249932,3.2433868662816987e-10,0.10039261208276562,145.19812090533188,17.08642856973807,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11-465,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,465.0,441.3,2.0,,,48.0,16.31,35.65,15.59,29.83,0.00544754,-0.08367055,43.1,1.2385913033921676,16.311993620650497,5.145051237619011e-12,0.1222290835713047,999.9677381562157,5.457818549904957,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH96N11B-465,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,465.0,441.3,2.0,,,48.0,16.31,35.65,15.59,29.83,0.00544754,-0.08367055,43.1,1.2385913033921676,16.311993620650497,5.145051237619011e-12,0.1222290835713047,999.9677381562157,5.457818549904957,-0.3102,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-480,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,480.0,451.0,1.69,,,66.0,13.65,45.07,12.76,37.62,0.007659151500000001,-0.13850011,43.7,1.8071236818574037,13.664192174555145,1.969258844401044e-10,0.15222126806228556,146.40606098743646,9.404131725861147,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-480,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,480.0,450.2,1.69,,,66.0,13.65,45.07,12.76,37.62,0.00971061,-0.134259023,44.0,1.8330793196885327,13.663324341653228,2.805275381547382e-10,0.14783310661125013,151.44628100966113,15.973158982734663,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-485,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,485.0,455.8,1.69,,,66.0,13.72,45.2,12.83,37.81,0.0076984292000000015,-0.1388996,43.7,1.8141531868280594,13.733416193751516,2.0298436868600383e-10,0.14453706878555622,147.81007804302786,9.62609080966332,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-485,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,485.0,455.1,1.69,,,66.0,13.72,45.2,12.83,37.81,0.009760408,-0.13464628,44.0,1.8401966889654024,13.732573675940476,2.8900452221960016e-10,0.14015157351181073,152.9289987735525,16.20426538999047,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-490,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,490.0,460.7,1.69,,,66.0,13.79,45.33,12.9,37.99,0.0077377068999999995,-0.13929909000000001,43.7,1.8209150457009124,13.802725625298011,2.0842473370889958e-10,0.1378410549150851,149.37012211013922,9.814494783367957,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-490,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,490.0,460.0,1.69,,,66.0,13.79,45.33,12.9,37.99,0.009810205999999998,-0.13503353699999998,44.0,1.8470440886094623,13.801905568215558,2.966155951703913e-10,0.13345944636787163,154.58362084764107,16.400400076418894,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-495,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,495.0,465.6,1.69,,,66.0,13.86,45.46,12.97,38.17,0.0077769846,-0.13969858000000002,43.7,1.8276746469206622,13.872048236179488,2.139649792781217e-10,0.13121933619705603,150.95156070355077,10.001548303460716,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-495,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,495.0,464.9,1.69,,,66.0,13.86,45.46,12.97,38.17,0.009860003999999999,-0.13542079399999998,44.0,1.8538888056306888,13.871250508983287,3.0436142815000987e-10,0.1268416651808631,156.2618684411986,16.595079085322002,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-500,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,500.0,470.5,1.69,,,66.0,13.93,45.59,13.04,38.35,0.0078162623,-0.14009807000000002,43.7,1.834432041726014,13.941383859915138,2.196060352960314e-10,0.12467067933691664,152.55481259877877,10.18726937031969,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-500,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,500.0,469.8,1.69,,,66.0,13.93,45.59,13.04,38.35,0.009909802,-0.135808051,44.0,1.860730880676639,13.940608336647088,3.122430812740194e-10,0.1202969980807336,157.96418525365343,16.788319189624023,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132P8-505,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,505.0,475.4,1.69,,,66.0,14.0,45.72,13.11,38.53,0.007855540000000001,-0.14049756,43.7,1.8411872365386468,14.010732334490266,2.2534869585659927e-10,0.11819388559759898,154.18029045506657,10.371670185835555,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH132P8-505,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,505.0,474.7,1.69,,,66.0,14.0,45.72,13.11,38.53,0.0099596,-0.136195308,44.0,1.8675703480992714,14.009978889181278,3.2026158625586874e-10,0.11382424061761647,159.69106466808816,16.98013716938354,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-525,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,525.0,495.1,1.69,,,72.0,13.65,49.15,12.76,41.15,0.007659151500000001,-0.15103795,43.7,1.974014325632289,13.663359260721915,2.0524583441920808e-10,0.15464872651617456,158.01437083515447,9.771144130464087,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-525,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,525.0,493.9,2.58,,,72.0,13.65,49.15,12.76,41.15,0.0056258475,-0.12324853999999999,43.3,1.8029303839947106,13.669063628340314,1.9246746871906336e-11,0.1842102787836347,131.89883206485595,11.483368377628219,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-525,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,525.0,493.9,2.58,,,72.0,13.65,49.15,12.76,41.15,0.0056258475,-0.12324853999999999,43.3,1.8029303839947106,13.669063628340314,1.9246746871906336e-11,0.1842102787836347,131.89883206485595,11.483368377628219,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-525,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,525.0,493.9,2.58,,,72.0,13.65,49.15,12.76,41.15,0.0056258475,-0.12324853999999999,43.3,1.8029303839947106,13.669063628340314,1.9246746871906336e-11,0.1842102787836347,131.89883206485595,11.483368377628219,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH144P8-525,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,525.0,494.3,1.69,,,72.0,13.65,49.15,12.76,41.15,0.00971061,-0.146412935,44.0,2.0023424202079405,13.662522259642062,2.92117652567232e-10,0.1498489541511452,163.3441863318851,16.355012008599736,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-530,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,530.0,500.0,1.69,,,72.0,13.72,49.3,12.83,41.31,0.0076984292000000015,-0.15149890000000002,43.7,1.9805737280191784,13.732949209433603,2.0776097884814584e-10,0.15126713833000177,160.2711897585007,9.832644660328313,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-530,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,530.0,498.7,2.58,,,72.0,13.72,49.3,12.83,41.31,0.0056546980000000005,-0.12362467999999999,43.3,1.8088752787538642,13.738586068200119,1.948155203545748e-11,0.18078835191432907,133.45567063467277,11.545528663368787,-0.33735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-530,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,530.0,498.7,2.58,,,72.0,13.72,49.3,12.83,41.31,0.0056546980000000005,-0.12362467999999999,43.3,1.8088752787538642,13.738586068200119,1.948155203545748e-11,0.18078835191432907,133.45567063467277,11.545528663368787,-0.33735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-530,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,530.0,498.7,2.58,,,72.0,13.72,49.3,12.83,41.31,0.0056546980000000005,-0.12362467999999999,43.3,1.8088752787538642,13.738586068200119,1.948155203545748e-11,0.18078835191432907,133.45567063467277,11.545528663368787,-0.33735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-WH144P8-530,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,530.0,499.2,1.69,,,72.0,13.72,49.3,12.83,41.31,0.009760408,-0.14685977,44.0,2.0089919288853966,13.732124006305096,2.9565453935187175e-10,0.14647587493568506,165.7578402561252,16.419112664416964,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-535,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,535.0,504.9,1.69,,,72.0,13.79,49.45,12.9,41.47,0.0077377068999999995,-0.15195985000000004,43.7,1.987133589652071,13.802547214636663,2.102925694377315e-10,0.14792243709392255,162.57396783557607,9.893813707510583,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-535,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,535.0,503.6,2.58,,,72.0,13.79,49.45,12.9,41.47,0.0056835485,-0.12400082,43.3,1.8148205914939317,13.808116587027929,1.971789817817989e-11,0.17740374065693684,135.03633930887713,11.607367309871014,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-535,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,535.0,503.6,2.58,,,72.0,13.79,49.45,12.9,41.47,0.0056835485,-0.12400082,43.3,1.8148205914939317,13.808116587027929,1.971789817817989e-11,0.17740374065693684,135.03633930887713,11.607367309871014,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-535,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,535.0,503.6,2.58,,,72.0,13.79,49.45,12.9,41.47,0.0056835485,-0.12400082,43.3,1.8148205914939317,13.808116587027929,1.971789817817989e-11,0.17740374065693684,135.03633930887713,11.607367309871014,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH144P8-535,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,535.0,504.1,1.69,,,72.0,13.79,49.45,12.9,41.47,0.009810205999999998,-0.147306605,44.0,2.015642168444481,13.80173379626739,2.992150274816033e-10,0.14313954993829722,168.22300603018573,16.482896622642798,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-540,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,540.0,509.8,1.69,,,72.0,13.86,49.6,12.97,41.64,0.0077769846,-0.15242080000000002,43.7,1.9939580263590784,13.872088065258444,2.1353809670115128e-10,0.14371706612330198,164.78390497285702,9.983770827718637,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-540,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,540.0,508.4,2.58,,,72.0,13.86,49.6,12.97,41.64,0.005712399,-0.12437696000000001,43.3,1.8209853904239413,13.877576119494247,2.0020845393446887e-11,0.17317163486483111,136.55795099063306,11.698477173806987,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-540,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,540.0,508.4,2.58,,,72.0,13.86,49.6,12.97,41.64,0.005712399,-0.12437696000000001,43.3,1.8209853904239413,13.877576119494247,2.0020845393446887e-11,0.17317163486483111,136.55795099063306,11.698477173806987,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-540,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,540.0,508.4,2.58,,,72.0,13.86,49.6,12.97,41.64,0.005712399,-0.12437696000000001,43.3,1.8209853904239413,13.877576119494247,2.0020845393446887e-11,0.17317163486483111,136.55795099063306,11.698477173806987,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH144P8-540,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,540.0,509.0,1.69,,,72.0,13.86,49.6,12.97,41.64,0.009860003999999999,-0.14775344,44.0,2.022558452500847,13.871288853619573,3.037676217275467e-10,0.13894139929841887,170.58666377057733,16.576592026855625,-0.39941,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,511.3,2.58,,,72.0,13.95,50.07,13.17,41.39,0.005161499999999999,-0.12272157000000002,43.3,1.8485754471560545,13.961687768533892,2.3764501689530254e-11,0.22534205061834817,268.958238408895,15.834609866792444,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,511.3,2.58,,,72.0,13.95,50.07,13.17,41.39,0.005161499999999999,-0.12272157000000002,43.3,1.8485754471560545,13.961687768533892,2.3764501689530254e-11,0.22534205061834817,268.958238408895,15.834609866792444,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,511.3,2.58,,,72.0,13.95,50.07,13.17,41.39,0.005161499999999999,-0.12272157000000002,43.3,1.8485754471560545,13.961687768533892,2.3764501689530254e-11,0.22534205061834817,268.958238408895,15.834609866792444,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,511.3,2.58,,,72.0,13.95,50.07,13.17,41.39,0.005161499999999999,-0.12272157000000002,43.3,1.8485754471560545,13.961687768533892,2.3764501689530254e-11,0.22534205061834817,268.958238408895,15.834609866792444,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,514.8,1.69,,,72.0,13.93,49.75,13.04,41.8,0.0078162623,-0.15288175,43.7,2.000518535480033,13.94170279390718,2.1610776320107634e-10,0.14044933127869777,167.17881731241212,10.044168136336198,-0.39606,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,513.2,2.58,,,72.0,13.93,49.75,13.04,41.8,0.0057412495,-0.12475309999999999,43.3,1.826931309813967,13.947123411188649,2.0260755839738603e-11,0.16986475659907066,138.186021599573,11.75954267782742,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,513.2,2.58,,,72.0,13.93,49.75,13.04,41.8,0.0057412495,-0.12475309999999999,43.3,1.826931309813967,13.947123411188649,2.0260755839738603e-11,0.16986475659907066,138.186021599573,11.75954267782742,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,513.2,2.58,,,72.0,13.93,49.75,13.04,41.8,0.0057412495,-0.12475309999999999,43.3,1.826931309813967,13.947123411188649,2.0260755839738603e-11,0.16986475659907066,138.186021599573,11.75954267782742,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH144P8-545,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,545.0,514.0,1.69,,,72.0,13.93,49.75,13.04,41.8,0.009909802,-0.148200275,44.0,2.0292090500118545,13.940915337795554,3.0737936643131734e-10,0.13568192413004718,173.1553626639447,16.639537077042007,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,516.2,2.58,,,72.0,14.01,50.27,13.23,41.58,0.005183699999999999,-0.12321177000000001,43.3,1.8562851581332667,14.021400194360623,2.3986159079902214e-11,0.22314075493342156,274.22357178676174,15.880470717827283,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,516.2,2.58,,,72.0,14.01,50.27,13.23,41.58,0.005183699999999999,-0.12321177000000001,43.3,1.8562851581332667,14.021400194360623,2.3986159079902214e-11,0.22314075493342156,274.22357178676174,15.880470717827283,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,516.2,2.58,,,72.0,14.01,50.27,13.23,41.58,0.005183699999999999,-0.12321177000000001,43.3,1.8562851581332667,14.021400194360623,2.3986159079902214e-11,0.22314075493342156,274.22357178676174,15.880470717827283,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,516.2,2.58,,,72.0,14.01,50.27,13.23,41.58,0.005183699999999999,-0.12321177000000001,43.3,1.8562851581332667,14.021400194360623,2.3986159079902214e-11,0.22314075493342156,274.22357178676174,15.880470717827283,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,519.7,1.69,,,72.0,14.0,49.9,13.11,41.96,0.007855540000000001,-0.1533427,43.7,2.007079493919573,14.011325250017466,2.1869384856901234e-10,0.13721666816753997,169.6239297924803,10.104242276348012,-0.39606,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,518.0,2.58,,,72.0,14.0,49.9,13.11,41.96,0.005770100000000001,-0.12512924,43.3,1.8328776103184494,14.01667844366055,2.050219684958606e-11,0.16659336758552,139.83961579969687,11.820284141387427,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,518.0,2.58,,,72.0,14.0,49.9,13.11,41.96,0.005770100000000001,-0.12512924,43.3,1.8328776103184494,14.01667844366055,2.050219684958606e-11,0.16659336758552,139.83961579969687,11.820284141387427,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,518.0,2.58,,,72.0,14.0,49.9,13.11,41.96,0.005770100000000001,-0.12512924,43.3,1.8328776103184494,14.01667844366055,2.050219684958606e-11,0.16659336758552,139.83961579969687,11.820284141387427,-0.33735,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-WH144P8-550,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,550.0,518.9,1.69,,,72.0,14.0,49.9,13.11,41.96,0.0099596,-0.14864711,44.0,2.035859964330157,14.010549512586921,3.110131960141585e-10,0.13245745644879167,175.78105553967893,16.702131026659583,-0.39941,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,521.0,2.58,,,72.0,14.07,50.47,13.29,41.77,0.0052059,-0.12370197000000002,43.3,1.8639945672451546,14.081117133205222,2.4208333042321672e-11,0.22095959754881586,279.64957511191983,15.925926469199311,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,521.0,2.58,,,72.0,14.07,50.47,13.29,41.77,0.0052059,-0.12370197000000002,43.3,1.8639945672451546,14.081117133205222,2.4208333042321672e-11,0.22095959754881586,279.64957511191983,15.925926469199311,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,521.0,2.58,,,72.0,14.07,50.47,13.29,41.77,0.0052059,-0.12370197000000002,43.3,1.8639945672451546,14.081117133205222,2.4208333042321672e-11,0.22095959754881586,279.64957511191983,15.925926469199311,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,521.0,2.58,,,72.0,14.07,50.47,13.29,41.77,0.0052059,-0.12370197000000002,43.3,1.8639945672451546,14.081117133205222,2.4208333042321672e-11,0.22095959754881586,279.64957511191983,15.925926469199311,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,522.9,2.58,,,72.0,14.07,50.05,13.18,42.12,0.005798950500000001,-0.12550537999999997,43.3,1.838824293392917,14.08624109282441,2.0745169495469195e-11,0.16335689930832376,141.51951467944642,11.880703783144275,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,522.9,2.58,,,72.0,14.07,50.05,13.18,42.12,0.005798950500000001,-0.12550537999999997,43.3,1.838824293392917,14.08624109282441,2.0745169495469195e-11,0.16335689930832376,141.51951467944642,11.880703783144275,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,522.9,2.58,,,72.0,14.07,50.05,13.18,42.12,0.005798950500000001,-0.12550537999999997,43.3,1.838824293392917,14.08624109282441,2.0745169495469195e-11,0.16335689930832376,141.51951467944642,11.880703783144275,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-555,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,555.0,522.9,2.58,,,72.0,14.07,50.05,13.18,42.12,0.005798950500000001,-0.12550537999999997,43.3,1.838824293392917,14.08624109282441,2.0745169495469195e-11,0.16335689930832376,141.51951467944642,11.880703783144275,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,525.8,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0052281,-0.12419217000000002,43.3,1.8714822365705572,14.14086249033226,2.435345955651433e-11,0.2196592773435755,285.734259244465,15.941021650157394,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,525.8,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0052281,-0.12419217000000002,43.3,1.8714822365705572,14.14086249033226,2.435345955651433e-11,0.2196592773435755,285.734259244465,15.941021650157394,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,525.8,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0052281,-0.12419217000000002,43.3,1.8714822365705572,14.14086249033226,2.435345955651433e-11,0.2196592773435755,285.734259244465,15.941021650157394,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,525.8,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0052281,-0.12419217000000002,43.3,1.8714822365705572,14.14086249033226,2.435345955651433e-11,0.2196592773435755,285.734259244465,15.941021650157394,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,527.7,2.58,,,72.0,14.14,50.2,13.25,42.28,0.0058278010000000005,-0.12588152,43.3,1.8447714466740617,14.155811323760961,2.0989698927811112e-11,0.16015478166882363,143.22574438186675,11.940817027134454,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,527.7,2.58,,,72.0,14.14,50.2,13.25,42.28,0.0058278010000000005,-0.12588152,43.3,1.8447714466740617,14.155811323760961,2.0989698927811112e-11,0.16015478166882363,143.22574438186675,11.940817027134454,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,527.7,2.58,,,72.0,14.14,50.2,13.25,42.28,0.0058278010000000005,-0.12588152,43.3,1.8447714466740617,14.155811323760961,2.0989698927811112e-11,0.16015478166882363,143.22574438186675,11.940817027134454,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-560,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,560.0,527.7,2.58,,,72.0,14.14,50.2,13.25,42.28,0.0058278010000000005,-0.12588152,43.3,1.8447714466740617,14.155811323760961,2.0989698927811112e-11,0.16015478166882363,143.22574438186675,11.940817027134454,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,530.6,2.58,,,72.0,14.19,50.87,13.41,42.14,0.005250299999999999,-0.12468236999999999,43.3,1.8791912084471205,14.200587580340294,2.4576331199242098e-11,0.21751361570315936,291.5225327050533,15.985820536364365,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,530.6,2.58,,,72.0,14.19,50.87,13.41,42.14,0.005250299999999999,-0.12468236999999999,43.3,1.8791912084471205,14.200587580340294,2.4576331199242098e-11,0.21751361570315936,291.5225327050533,15.985820536364365,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,530.6,2.58,,,72.0,14.19,50.87,13.41,42.14,0.005250299999999999,-0.12468236999999999,43.3,1.8791912084471205,14.200587580340294,2.4576331199242098e-11,0.21751361570315936,291.5225327050533,15.985820536364365,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,530.6,2.58,,,72.0,14.19,50.87,13.41,42.14,0.005250299999999999,-0.12468236999999999,43.3,1.8791912084471205,14.200587580340294,2.4576331199242098e-11,0.21751361570315936,291.5225327050533,15.985820536364365,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,532.5,2.58,,,72.0,14.21,50.33,13.32,42.42,0.005856651500000001,-0.126207508,43.3,1.8499153123611873,14.225412348410089,2.1214513242547232e-11,0.15719441926012429,144.93136584684805,11.991488628504543,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8B-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,532.5,2.58,,,72.0,14.21,50.33,13.32,42.42,0.005856651500000001,-0.126207508,43.3,1.8499153123611873,14.225412348410089,2.1214513242547232e-11,0.15719441926012429,144.93136584684805,11.991488628504543,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8b-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,532.5,2.58,,,72.0,14.21,50.33,13.32,42.42,0.005856651500000001,-0.126207508,43.3,1.8499153123611873,14.225412348410089,2.1214513242547232e-11,0.15719441926012429,144.93136584684805,11.991488628504543,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144P8T-565,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,565.0,532.5,2.58,,,72.0,14.21,50.33,13.32,42.42,0.005856651500000001,-0.126207508,43.3,1.8499153123611873,14.225412348410089,2.1214513242547232e-11,0.15719441926012429,144.93136584684805,11.991488628504543,-0.33735,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-570,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,570.0,535.4,2.58,,,72.0,14.25,51.07,13.48,42.29,0.0052725,-0.12517257,43.3,1.8853574996711062,14.259608583976219,2.4280041182219065e-11,0.21883790596395072,324.5473215404843,15.827375063990853,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-570,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,570.0,535.4,2.58,,,72.0,14.25,51.07,13.48,42.29,0.0052725,-0.12517257,43.3,1.8853574996711062,14.259608583976219,2.4280041182219065e-11,0.21883790596395072,324.5473215404843,15.827375063990853,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-570,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,570.0,535.4,2.58,,,72.0,14.25,51.07,13.48,42.29,0.0052725,-0.12517257,43.3,1.8853574996711062,14.259608583976219,2.4280041182219065e-11,0.21883790596395072,324.5473215404843,15.827375063990853,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-570,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,570.0,535.4,2.58,,,72.0,14.25,51.07,13.48,42.29,0.0052725,-0.12517257,43.3,1.8853574996711062,14.259608583976219,2.4280041182219065e-11,0.21883790596395072,324.5473215404843,15.827375063990853,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-575,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,575.0,540.3,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0052947,-0.12566277,43.3,1.8915288813833357,14.318614855645484,2.3991116377033418e-11,0.22014692007200748,365.68256130019444,15.670815837877708,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-575,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,575.0,540.3,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0052947,-0.12566277,43.3,1.8915288813833357,14.318614855645484,2.3991116377033418e-11,0.22014692007200748,365.68256130019444,15.670815837877708,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-575,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,575.0,540.3,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0052947,-0.12566277,43.3,1.8915288813833357,14.318614855645484,2.3991116377033418e-11,0.22014692007200748,365.68256130019444,15.670815837877708,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-575,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,575.0,540.3,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0052947,-0.12566277,43.3,1.8915288813833357,14.318614855645484,2.3991116377033418e-11,0.22014692007200748,365.68256130019444,15.670815837877708,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-580,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,580.0,545.1,2.58,,,72.0,14.37,51.47,13.62,42.59,0.005316899999999999,-0.12615297000000003,43.3,1.8977052577240092,14.377606611459843,2.3709313333535465e-11,0.22144092371385518,418.33425468243473,15.516108278445172,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-580,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,580.0,545.1,2.58,,,72.0,14.37,51.47,13.62,42.59,0.005316899999999999,-0.12615297000000003,43.3,1.8977052577240092,14.377606611459843,2.3709313333535465e-11,0.22144092371385518,418.33425468243473,15.516108278445172,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-580,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,580.0,545.1,2.58,,,72.0,14.37,51.47,13.62,42.59,0.005316899999999999,-0.12615297000000003,43.3,1.8977052577240092,14.377606611459843,2.3709313333535465e-11,0.22144092371385518,418.33425468243473,15.516108278445172,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-580,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,580.0,545.1,2.58,,,72.0,14.37,51.47,13.62,42.59,0.005316899999999999,-0.12615297000000003,43.3,1.8977052577240092,14.377606611459843,2.3709313333535465e-11,0.22144092371385518,418.33425468243473,15.516108278445172,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-585,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,585.0,549.9,2.58,,,72.0,14.43,51.67,13.69,42.74,0.0053391,-0.12664317000000003,43.3,1.903886537894672,14.436584065170477,2.343439940827165e-11,0.22272017580216677,488.1257441204374,15.3632194326262,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-585,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,585.0,549.9,2.58,,,72.0,14.43,51.67,13.69,42.74,0.0053391,-0.12664317000000003,43.3,1.903886537894672,14.436584065170477,2.343439940827165e-11,0.22272017580216677,488.1257441204374,15.3632194326262,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-585,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,585.0,549.9,2.58,,,72.0,14.43,51.67,13.69,42.74,0.0053391,-0.12664317000000003,43.3,1.903886537894672,14.436584065170477,2.343439940827165e-11,0.22272017580216677,488.1257441204374,15.3632194326262,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-585,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,585.0,549.9,2.58,,,72.0,14.43,51.67,13.69,42.74,0.0053391,-0.12664317000000003,43.3,1.903886537894672,14.436584065170477,2.343439940827165e-11,0.22272017580216677,488.1257441204374,15.3632194326262,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-590,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,590.0,561.0,2.58,,,72.0,13.89,52.37,13.28,44.43,0.00441702,-0.12128891999999998,43.5,1.7833397963879094,13.89266947514133,2.439483743714732e-12,0.1670111300857707,869.0040100168001,1.865275540291117,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-590,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,590.0,561.0,2.58,,,72.0,13.89,52.37,13.28,44.43,0.00441702,-0.12128891999999998,43.5,1.7833397963879094,13.89266947514133,2.439483743714732e-12,0.1670111300857707,869.0040100168001,1.865275540291117,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8b-590,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,590.0,554.8,2.58,,,72.0,14.49,51.86,13.76,42.88,0.005361299999999999,-0.12710886,43.3,1.909666401835413,14.495547380667528,2.315373307856972e-11,0.22408625794941614,585.3229740117788,15.207095068701063,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8T-590,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,590.0,554.8,2.58,,,72.0,14.49,51.86,13.76,42.88,0.005361299999999999,-0.12710886,43.3,1.909666401835413,14.495547380667528,2.315373307856972e-11,0.22408625794941614,585.3229740117788,15.207095068701063,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-595,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,595.0,564.6,2.7,,,66.0,15.75,47.91,14.9,39.94,0.004536,-0.11263640999999999,43.5,1.6340230485221907,15.764995528539187,2.865940071281122e-12,0.18639527890416036,195.77340253252422,0.7241906184007824,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-595,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,595.0,564.6,2.7,,,66.0,15.75,47.91,14.9,39.94,0.004536,-0.11263640999999999,43.5,1.6340230485221907,15.764995528539187,2.865940071281122e-12,0.18639527890416036,195.77340253252422,0.7241906184007824,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-595,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,595.0,565.8,2.58,,,72.0,13.93,52.58,13.33,44.64,0.004429740000000001,-0.12177528000000001,43.5,1.7903756738044696,13.932023946175088,2.444243749825823e-12,0.16458055065704139,1132.74098561074,1.8533700874917387,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-595,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,595.0,565.8,2.58,,,72.0,13.93,52.58,13.33,44.64,0.004429740000000001,-0.12177528000000001,43.5,1.7903756738044696,13.932023946175088,2.444243749825823e-12,0.16458055065704139,1132.74098561074,1.8533700874917387,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-595,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,595.0,564.3,2.8,,,156.0,14.03,54.57,13.23,44.99,0.006119324800000001,-0.125571027,43.3,1.888161283632367,14.047653717068012,3.87462000777735e-12,0.2755816790848566,219.013987524511,6.313021913599167,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-595,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,595.0,564.3,2.8,,,156.0,14.03,54.57,13.23,44.99,0.006119324800000001,-0.125571027,43.3,1.888161283632367,14.047653717068012,3.87462000777735e-12,0.2755816790848566,219.013987524511,6.313021913599167,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-600,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,600.0,569.5,2.7,,,66.0,15.78,48.11,14.92,40.22,0.00454464,-0.11310661000000001,43.5,1.6433984929052656,15.7951638521888,3.0025469110588577e-12,0.17818602305093476,185.4261971997775,1.1008203097595,-0.2973,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-600,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,600.0,569.5,2.7,,,66.0,15.78,48.11,14.92,40.22,0.00454464,-0.11310661000000001,43.5,1.6433984929052656,15.7951638521888,3.0025469110588577e-12,0.17818602305093476,185.4261971997775,1.1008203097595,-0.2973,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-600,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,600.0,570.7,2.58,,,72.0,13.97,52.79,13.38,44.85,0.0044424600000000005,-0.12226164,43.5,1.7974103135008181,13.971398733947536,2.448963750698461e-12,0.16216882982520267,1619.6780155664444,1.8413835821560744,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-600,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,600.0,570.7,2.58,,,72.0,13.97,52.79,13.38,44.85,0.0044424600000000005,-0.12226164,43.5,1.7974103135008181,13.971398733947536,2.448963750698461e-12,0.16216882982520267,1619.6780155664444,1.8413835821560744,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-600,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,600.0,569.1,2.8,,,156.0,14.09,54.76,13.28,45.2,0.0061454944,-0.126008236,43.3,1.896204919820775,14.108130029351404,3.976574379601013e-12,0.2707851353463433,210.44436783655414,6.506525158515582,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-600,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,600.0,569.1,2.8,,,156.0,14.09,54.76,13.28,45.2,0.0061454944,-0.126008236,43.3,1.896204919820775,14.108130029351404,3.976574379601013e-12,0.2707851353463433,210.44436783655414,6.506525158515582,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-605,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,605.0,574.3,2.7,,,66.0,15.81,48.31,14.94,40.5,0.004553280000000001,-0.11357681000000001,43.5,1.65277984025581,15.825245473137345,3.1443793863573066e-12,0.16999940543991265,176.29433806754992,1.4751946813714578,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-605,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,605.0,574.3,2.7,,,66.0,15.81,48.31,14.94,40.5,0.004553280000000001,-0.11357681000000001,43.5,1.65277984025581,15.825245473137345,3.1443793863573066e-12,0.16999940543991265,176.29433806754992,1.4751946813714578,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8-605,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,605.0,575.6,2.58,,,72.0,14.16,53.5,13.55,44.65,0.004502880000000001,-0.123906,43.5,1.807626161633302,14.161553429503812,1.979637142275894e-12,0.2291004997856613,2088.3230767231385,-0.055475846353448106,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH144N8B-605,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,605.0,575.6,2.58,,,72.0,14.16,53.5,13.55,44.65,0.004502880000000001,-0.123906,43.5,1.807626161633302,14.161553429503812,1.979637142275894e-12,0.2291004997856613,2088.3230767231385,-0.055475846353448106,-0.291,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-605,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,605.0,574.0,2.8,,,156.0,14.15,54.92,13.33,45.39,0.006171664000000001,-0.12637641200000002,43.3,1.9033050807917562,14.168559354025833,4.086301198955584e-12,0.2654694921776078,202.39892608228487,6.711482320224858,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-605,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,605.0,574.0,2.8,,,156.0,14.15,54.92,13.33,45.39,0.006171664000000001,-0.12637641200000002,43.3,1.9033050807917562,14.168559354025833,4.086301198955584e-12,0.2654694921776078,202.39892608228487,6.711482320224858,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-610,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,610.0,579.2,2.7,,,66.0,15.84,48.51,14.96,40.78,0.0045619200000000006,-0.11404700999999999,43.5,1.6621670542908744,15.855242828554733,3.291584413145731e-12,0.16183527312536425,168.1755271156778,1.8473353693215824,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-610,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,610.0,579.2,2.7,,,66.0,15.84,48.51,14.96,40.78,0.0045619200000000006,-0.11404700999999999,43.5,1.6621670542908744,15.855242828554733,3.291584413145731e-12,0.16183527312536425,168.1755271156778,1.8473353693215824,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-610,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,610.0,578.8,2.8,,,156.0,14.21,55.1,13.38,45.6,0.006197833600000001,-0.12679061000000003,43.3,1.911168167319618,14.228943773781968,4.202624062385377e-12,0.2599943456453729,195.02553727504252,6.924433982332349,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-610,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,610.0,578.8,2.8,,,156.0,14.21,55.1,13.38,45.6,0.006197833600000001,-0.12679061000000003,43.3,1.911168167319618,14.228943773781968,4.202624062385377e-12,0.2599943456453729,195.02553727504252,6.924433982332349,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-615,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,615.0,584.0,2.7,,,66.0,15.87,48.71,14.98,41.06,0.00457056,-0.11451721000000001,43.5,1.6715600972225273,15.885158239258248,3.444311310000316e-12,0.1536934760412113,160.91021063918598,2.217264472747267,-0.2973,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-615,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,615.0,584.0,2.7,,,66.0,15.87,48.71,14.98,41.06,0.00457056,-0.11451721000000001,43.5,1.6715600972225273,15.885158239258248,3.444311310000316e-12,0.1536934760412113,160.91021063918598,2.217264472747267,-0.2973,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-615,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,615.0,583.7,2.8,,,156.0,14.27,55.26,13.44,45.76,0.0062240032,-0.127158786,43.3,1.9170395912201599,14.28859308190027,4.241892590312048e-12,0.25731672835295694,197.48795408052086,6.9683430568451055,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-615,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,615.0,583.7,2.8,,,156.0,14.27,55.26,13.44,45.76,0.0062240032,-0.127158786,43.3,1.9170395912201599,14.28859308190027,4.241892590312048e-12,0.25731672835295694,197.48795408052086,6.9683430568451055,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-620,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,620.0,588.9,2.7,,,66.0,15.9,48.91,15.0,41.34,0.0045792,-0.11498741,43.5,1.680958966042849,15.914993962062317,3.6027138483444617e-12,0.1455738625974305,154.37043307093245,2.585008297357228,-0.2973,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-620,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,620.0,588.9,2.7,,,66.0,15.9,48.91,15.0,41.34,0.0045792,-0.11498741,43.5,1.680958966042849,15.914993962062317,3.6027138483444617e-12,0.1455738625974305,154.37043307093245,2.585008297357228,-0.2973,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-620,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,620.0,588.5,2.8,,,156.0,14.33,55.47,13.51,45.92,0.006250172800000001,-0.127642017,43.3,1.923193606164824,14.347559017698797,4.1931301319195205e-12,0.2584001617858588,210.88163283813824,6.8245463871393754,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-620,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,620.0,588.5,2.8,,,156.0,14.33,55.47,13.51,45.92,0.006250172800000001,-0.127642017,43.3,1.923193606164824,14.347559017698797,4.1931301319195205e-12,0.2584001617858588,210.88163283813824,6.8245463871393754,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-625,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,625.0,593.7,2.7,,,66.0,15.93,49.11,15.02,41.62,0.00458784,-0.11545761,43.5,1.6903636309692562,15.944752152556852,3.766946840371937e-12,0.13747628809774382,148.45272664045217,2.9505887878104944,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-625,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,625.0,593.7,2.7,,,66.0,15.93,49.11,15.02,41.62,0.00458784,-0.11545761,43.5,1.6903636309692562,15.944752152556852,3.766946840371937e-12,0.13747628809774382,148.45272664045217,2.9505887878104944,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-625,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,625.0,593.4,2.8,,,156.0,14.39,55.63,13.58,46.05,0.0062763424,-0.12801019300000002,43.3,1.9278438640480167,14.406471594453626,4.159380073794676e-12,0.2582830007259733,225.6425387545315,6.711855716392731,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-625,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,625.0,593.4,2.8,,,156.0,14.39,55.63,13.58,46.05,0.0062763424,-0.12801019300000002,43.3,1.9278438640480167,14.406471594453626,4.159380073794676e-12,0.2582830007259733,225.6425387545315,6.711855716392731,-0.29917,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-630,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,630.0,598.6,2.7,,,66.0,15.96,49.31,15.04,41.89,0.00459648,-0.11592781,43.5,1.6995842977596718,15.97450873182789,3.924514985322999e-12,0.13015415788503976,143.17311698237052,3.2865340824344162,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-630,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,630.0,598.6,2.7,,,66.0,15.96,49.31,15.04,41.89,0.00459648,-0.11592781,43.5,1.6995842977596718,15.97450873182789,3.924514985322999e-12,0.13015415788503976,143.17311698237052,3.2865340824344162,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-630,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,630.0,598.3,2.8,,,156.0,14.45,55.79,13.65,46.18,0.006302512,-0.128378369,43.3,1.9324996651505064,14.465382175666079,4.126391709170314e-12,0.2581652771476472,242.5201962055434,6.600464467349626,-0.29917,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-630,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,630.0,598.3,2.8,,,156.0,14.45,55.79,13.65,46.18,0.006302512,-0.128378369,43.3,1.9324996651505064,14.465382175666079,4.126391709170314e-12,0.2581652771476472,242.5201962055434,6.600464467349626,-0.29917,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-635,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,635.0,603.5,2.7,,,66.0,15.99,49.51,15.06,42.17,0.00460512,-0.11639801,43.5,1.709000427627914,16.004122021266515,4.100405120431165e-12,0.12209906555884645,138.24961898116862,3.6479583230151755,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-635,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,635.0,603.5,2.7,,,66.0,15.99,49.51,15.06,42.17,0.00460512,-0.11639801,43.5,1.709000427627914,16.004122021266515,4.100405120431165e-12,0.12209906555884645,138.24961898116862,3.6479583230151755,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11-640,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,640.0,608.3,2.7,,,66.0,16.02,49.71,15.08,42.45,0.00461376,-0.11686821000000001,43.5,1.718422209116554,16.033663628321868,4.282587719598126e-12,0.11406561047493607,133.7368842572482,4.007275333043698,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Runergy New Energy Technology Co Ltd HY-DH132N11B-640,Jiangsu Runergy New Energy Technology Co Ltd,Mono-c-Si,0,640.0,608.3,2.7,,,66.0,16.02,49.71,15.08,42.45,0.00461376,-0.11686821000000001,43.5,1.718422209116554,16.033663628321868,4.282587719598126e-12,0.11406561047493607,133.7368842572482,4.007275333043698,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-355,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,355.0,331.9,1.82,,,60.0,11.43,40.9,10.61,33.5,0.0049720499999999996,-0.0978328,46.56,1.4415926768816878,11.461365774626213,5.2700848807346135e-12,0.2727883126079383,99.4067659936915,6.718210982405013,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-360,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,360.0,336.7,1.82,,,60.0,11.53,41.1,10.69,33.7,0.00501555,-0.0983112,46.56,1.4502139449278417,11.562525830864805,5.473903051057866e-12,0.2678691383255198,94.95625743148796,6.980289481715394,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-365,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,365.0,341.5,1.82,,,60.0,11.63,41.3,10.77,33.9,0.005059050000000001,-0.09878959999999999,46.56,1.4588358902642369,11.663639458127761,5.683318357800077e-12,0.2630228974789211,90.93357798113257,7.239952793247548,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-370,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,370.0,346.3,1.82,,,60.0,11.72,41.5,10.86,34.1,0.0050982,-0.09926800000000001,46.56,1.4662384195906344,11.752821443199876,5.768364051019072e-12,0.2584849646699995,92.30074896933499,7.300556027574149,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-375,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,375.0,351.1,1.82,,,60.0,11.85,41.6,10.98,34.2,0.00515475,-0.0995072,46.56,1.4701774025900023,11.88301500408484,5.877510016997187e-12,0.25440249060504205,91.31210493146175,7.368864920554003,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-380,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,380.0,355.9,1.82,,,60.0,11.98,41.7,11.09,34.3,0.0052112999999999994,-0.09974640000000001,46.56,1.4747393456887778,12.01415219863381,6.053308003294596e-12,0.25039669823556837,87.83482669913104,7.536801203038828,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-385,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,385.0,360.7,1.82,,,60.0,12.12,41.8,11.2,34.4,0.0052721999999999995,-0.0999856,46.56,1.4798698727188253,12.156167826111911,6.3001212381208915e-12,0.2462548295066753,82.52109285771455,7.794944786765781,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-166M-390,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,390.0,365.5,1.82,,,60.0,12.25,41.9,11.31,34.5,0.005328749999999999,-0.10022479999999999,46.56,1.484414668719083,12.2872564479815,6.48339769389006e-12,0.24241247151561152,79.70574062436565,7.95833226263567,-0.3098,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-415,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,415.0,384.5,2.17,,,72.0,11.2,48.8,10.41,39.9,0.0058016,-0.1253184,46.8,1.807345729773054,11.226152263793725,2.0413544579480584e-11,0.32084817980415997,137.4068289492326,11.00088671608297,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-420,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,420.0,389.3,2.17,,,72.0,11.29,49.0,10.49,40.1,0.0058482199999999995,-0.12583199999999997,46.8,1.8159068320662386,11.316438386178886,2.092312542106485e-11,0.3155688173545268,134.75754310263758,11.152950489917249,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-425,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,425.0,394.0,2.17,,,72.0,11.38,49.2,10.56,40.03,0.00589484,-0.1263456,46.8,1.8190008143188086,11.409866074144146,1.976321970548391e-11,0.3399056477181597,129.51572516788542,10.570834723976061,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-430,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,430.0,398.8,2.17,,,72.0,11.46,49.4,10.63,40.05,0.00593628,-0.12685919999999998,46.8,1.823401307937803,11.491673045963855,1.903584212802382e-11,0.3544451036297933,128.24598279746797,10.171836635194719,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-435,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,435.0,405.0,2.14,,,60.0,13.69,40.88,12.68,34.33,0.00721463,-0.10632888000000001,46.17,1.5334126396367804,13.713927982692457,3.48655394121684e-11,0.1381498793961332,79.04017150861935,12.611871919922503,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-435,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,435.0,403.5,2.17,,,72.0,11.53,49.6,10.7,40.07,0.00597254,-0.1273728,46.8,1.8270340713767954,11.562394573090026,1.813339582515833e-11,0.3690923054871992,131.3687413026154,9.679988159450414,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-440,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,440.0,409.7,2.14,,,60.0,13.76,41.03,12.77,34.48,0.007251519999999999,-0.10671902999999999,46.17,1.5380585847208383,13.782255945758187,3.453146541832448e-11,0.1360088131272389,84.0890473001766,12.469262377108366,-0.3397,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-440,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,440.0,408.3,2.17,,,72.0,11.6,49.8,10.77,40.09,0.006008799999999999,-0.12788639999999998,46.8,1.8306689879745657,11.63303439221858,1.7277394718581904e-11,0.38355399020060216,134.68467290154882,9.19238389884209,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-445,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,445.0,414.5,2.14,,,60.0,13.83,41.18,12.86,34.63,0.0072884099999999995,-0.10710918,46.17,1.5427162380339006,13.850627683522623,3.420913735680726e-11,0.13389423462677044,89.77049070904208,12.32938972808483,-0.3397,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-445,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,445.0,413.1,2.17,,,72.0,11.72,49.9,10.86,41.0,0.00607096,-0.12814319999999998,46.8,1.855517850043179,11.748808991110758,2.370331202667015e-11,0.2920995630147902,118.83119684028665,11.957514444298116,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-450,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,450.0,419.3,2.14,,,60.0,13.9,41.33,12.95,34.78,0.0073253,-0.10749933,46.17,1.547385097649973,13.919042438046464,3.3897939418472804e-11,0.1318057200053664,96.21139430773383,12.192149086720699,-0.3397,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-450,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,450.0,417.9,2.17,,,72.0,11.83,50.0,10.96,41.1,0.00612794,-0.1284,46.8,1.8598128034458938,11.859087005094441,2.4119974432223084e-11,0.2880741395654928,117.16287306994253,12.031923927074489,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-455,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,455.0,424.1,2.14,,,60.0,13.97,41.48,13.04,34.93,0.00736219,-0.10788948,46.17,1.5520649367758022,13.98749946030802,3.3597441021537426e-11,0.12974280813059336,103.57502493927159,12.057480548851803,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-455,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,455.0,422.6,2.17,,,72.0,11.96,50.1,11.06,41.2,0.00619528,-0.1286568,46.8,1.8164706454426325,11.960007544382675,1.2573894308368417e-11,0.29261348241402313,463880.42819722096,6.036221480257701,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-460,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,460.0,428.9,2.14,,,60.0,14.04,41.63,13.13,35.08,0.00739908,-0.10827963000000002,46.17,1.5567554591177526,14.05599801468851,3.3307189541559366e-11,0.12770506075005808,112.07509781099024,11.925314182616587,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-460,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,460.0,427.4,2.17,,,72.0,12.06,50.2,11.15,41.3,0.00624708,-0.1289136,46.8,1.8699852097431633,12.091355289706271,2.5509558406967243e-11,0.2799098214419476,107.6600628571796,12.375752154275192,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE60-18X-465,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,465.0,433.7,2.14,,,60.0,14.11,41.78,13.22,35.23,0.00743597,-0.10866978,46.17,1.5614564025709827,14.12453739355167,3.3026769260081305e-11,0.12569204475416468,121.9967495886384,11.795585846969278,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-166M-465,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,465.0,432.2,2.17,,,72.0,12.18,50.3,11.24,41.4,0.00630924,-0.1291704,46.8,1.8758524583760048,12.21331872648476,2.6505732006313862e-11,0.27576887070096046,100.81012129991882,12.643125449802634,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-520,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,520.0,483.9,2.59,,,72.0,13.63,48.9,12.68,41.05,0.00603809,-0.1236681,46.56,1.7996838531000532,13.65191282955289,2.089818093864656e-11,0.17327042855361352,107.77594656926733,11.269554191044985,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-525,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,525.0,488.7,2.59,,,72.0,13.7,49.05,12.75,41.2,0.006069099999999999,-0.12404745,46.56,1.8053963824654322,13.721477370684426,2.1074674486902847e-11,0.17079132805948302,108.94449022137772,11.297769467899302,-0.3339,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-530,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,530.0,493.5,2.59,,,72.0,13.76,49.2,12.83,41.35,0.00609568,-0.12442680000000002,46.56,1.8097639957263842,13.77988415105006,2.0848753802145735e-11,0.16864519647309187,116.70389668458053,11.152716662026295,-0.3339,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-535,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,535.0,498.2,2.59,,,72.0,13.83,49.35,12.9,41.5,0.00612669,-0.12480615000000002,46.56,1.815481390128881,13.849476979240366,2.1025580460469192e-11,0.16621885933245611,118.02686661626535,11.181717628923115,-0.3339,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-540,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,540.0,503.0,2.59,,,72.0,13.9,49.5,12.97,41.65,0.0061577,-0.1251855,46.56,1.8211997072388482,13.919075877657406,2.1203169921918114e-11,0.16381857965097807,119.36951501318822,11.210655703133126,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-545,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,545.0,507.8,2.59,,,72.0,13.95,49.65,13.05,41.8,0.006179849999999999,-0.12556485,46.56,1.8249458676370873,13.967011533387208,2.078644259208022e-11,0.16195058998098424,132.80465004947365,10.987824830767714,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-550,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,550.0,512.6,2.59,,,72.0,14.0,49.8,13.12,41.95,0.006202,-0.1259442,46.56,1.8293918263333946,14.015560235757585,2.0574169158323622e-11,0.16000524285001266,143.96140543690993,10.855294718261884,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-555,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,555.0,517.4,2.59,,,72.0,14.07,49.95,13.2,42.1,0.006233010000000001,-0.12632355000000003,46.56,1.8344405334103533,14.084653746004761,2.056123418483209e-11,0.15777064763399756,151.48570330222225,10.799979522973985,-0.3339,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE72-18X-560,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,560.0,522.2,2.59,,,72.0,14.14,50.1,13.27,42.25,0.0062640199999999995,-0.1267029,46.56,1.840170035315678,14.154320527169302,2.073800738190878e-11,0.15546650906892287,153.5066704999664,10.831079051664055,-0.3339,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-560,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,560.0,521.1,2.8,,,78.0,13.54,52.89,12.62,44.38,0.005998219999999999,-0.13375881,46.56,1.94429216007289,13.560490540296966,2.0166716914508303e-11,0.19066736127160477,125.99160593991095,10.999200610385131,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-565,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,565.0,525.8,2.8,,,78.0,13.61,53.04,12.69,44.53,0.00602923,-0.13413816,46.56,1.9499798501826977,13.630091136845571,2.0328066339753338e-11,0.18808870733004776,127.41376136192076,11.023080448682174,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-570,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,1,570.0,530.6,2.8,,,78.0,13.68,53.19,12.76,44.68,0.00606024,-0.13451751,46.56,1.9556688233748458,13.699697415970608,2.049015281529289e-11,0.18553808630827107,128.85756339083767,11.046973609086319,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-575,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,575.0,535.4,2.8,,,78.0,13.75,53.34,12.83,44.83,0.00609125,-0.13489686000000004,46.56,1.9613590689522025,13.769309313394666,2.0652976458058218e-11,0.18301504285572,130.32347636902642,11.070878831633339,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-580,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,580.0,540.2,2.8,,,78.0,13.82,53.49,12.9,44.98,0.006122260000000001,-0.13527621,46.56,1.9670505423024598,13.838926754574485,2.0816527965095332e-11,0.18051913680079718,131.8120583125335,11.094791207093397,-0.3339,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-585,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,585.0,545.0,2.8,,,78.0,13.89,53.64,12.97,45.13,0.00615327,-0.13565556,46.56,1.9727432669430571,13.908549680837819,2.0980816891052243e-11,0.17804992705953934,133.32377612179417,11.118712308631896,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-590,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,590.0,549.8,2.8,,,78.0,13.96,53.79,13.04,45.28,0.00618428,-0.13603491,46.56,1.9784371676317387,13.97817801374419,2.1145825104984264e-11,0.1756069968861838,134.8592710964624,11.142634475601302,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-595,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,595.0,554.5,2.8,,,78.0,14.03,53.94,13.11,45.43,0.00621529,-0.13641426,46.56,1.9841322700864124,14.047811704252437,2.131156246846165e-11,0.17318992285975496,136.41898559384623,11.166560497326737,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd FE78-18X-600,Jiangsu Xiehang New Energy Intelligent Equipment Co Ltd,Mono-c-Si,0,600.0,559.3,2.8,,,78.0,14.1,54.09,13.17,45.58,0.006246299999999999,-0.13679361,46.56,1.9905717574790742,14.118010290071243,2.1677740552223118e-11,0.17069260428808836,133.63281289715925,11.277522826444518,-0.3339,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangyin Hareon Power HR-165W/24V,Jiangyin Hareon Power,Mono-c-Si,0,165.0,148.0,1.2766400000000002,1.58,0.808,72.0,5.07,43.0,4.75,34.8,0.0021801,-0.1419,45.4,1.7982318706044338,5.074943074060467,2.0631598600706768e-10,0.6138150237517097,629.5764003500727,10.83012550750499,-0.463,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangyin Hareon Power HR-170W/24V,Jiangyin Hareon Power,Mono-c-Si,0,170.0,152.6,1.2766400000000002,1.58,0.808,72.0,5.14,43.8,4.83,35.2,0.0022102,-0.14454,45.4,1.8214891713849721,5.143616562379509,1.837611304592452e-10,0.6775664053010497,962.9841335028784,9.665419055265769,-0.463,N,2025.7.3,6/23/2025,4.0,first_pass +Jiangyin Hareon Power HR-240P-AC/Bb,Jiangyin Hareon Power,Multi-c-Si,0,240.0,216.1,1.622912,1.636,0.992,60.0,8.48,37.25,8.09,29.67,0.0048336,-0.1300025,45.8,1.5508203598437262,8.480002941393098,3.139338032707148e-10,0.3466524414299198,999998.387781962,3.7664982726074907,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +Jiangyin Hareon Power HR-240P-AC/BbP,Jiangyin Hareon Power,Multi-c-Si,0,240.0,213.1,1.622912,1.636,0.992,60.0,8.48,37.25,8.09,29.67,0.0033072,-0.12665,47.1,1.5672190725029838,8.480002888828379,4.036355751212381e-10,0.34041040916047494,999998.1531003068,8.925384710233521,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM200M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,200.0,178.9,1.6367999999999998,1.65,0.992,60.0,7.45,36.6,6.93,28.9,0.0059898,-0.13794540000000002,46.8,1.5429449669017246,7.4633026090795935,3.6552517322912593e-10,0.4698652903520762,263.14366044927215,-1.9875284176540142,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM200P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,200.0,178.7,1.6367999999999998,1.65,0.992,60.0,7.61,36.3,6.95,28.8,0.005327000000000001,-0.1256706,46.9,1.5290262685930778,7.640634830247356,3.5758996451330497e-10,0.43926562998844476,109.11801127689655,6.603013107946201,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM205M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,205.0,183.4,1.6367999999999998,1.65,0.992,60.0,7.56,36.7,7.05,29.1,0.00607824,-0.1383223,46.8,1.5490063222263553,7.570990602084006,3.824996257725966e-10,0.44372917518248023,305.2238121977488,-1.7481213748365827,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM205P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,205.0,183.3,1.6367999999999998,1.65,0.992,60.0,7.72,36.4,7.1,28.9,0.005404000000000001,-0.1260168,46.9,1.5280287371387145,7.744558298989353,3.373572252220716e-10,0.4307443118244307,135.40622034157653,5.957135040826085,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM210M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,210.0,188.0,1.6367999999999998,1.65,0.992,60.0,7.66,36.8,7.17,29.3,0.00615864,-0.1386992,46.8,1.5539962953257154,7.667723775889128,3.9368242706656453e-10,0.41902239034522265,415.5626319483527,-1.6319595872801118,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM210P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,210.0,187.9,1.6367999999999998,1.65,0.992,60.0,7.89,36.5,7.22,29.1,0.005523,-0.126363,46.9,1.5403067511151385,7.918572189769611,3.8812133831815634e-10,0.4026887382626809,111.19954327568556,6.995682056906567,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM215M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,215.0,192.6,1.6367999999999998,1.65,0.992,60.0,7.8,36.8,7.29,29.8,0.0062712,-0.1386992,46.8,1.5713189693061618,7.8084251570072345,5.184594528724824e-10,0.32997718867056186,305.4925535403213,0.45404509551157374,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM215P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,215.0,192.4,1.6367999999999998,1.65,0.992,60.0,7.97,36.7,7.37,29.2,0.005579,-0.1270554,46.9,1.5380357896772043,7.989927163058804,3.3671459377989057e-10,0.41066894339651044,164.2497669321396,5.651821103858629,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM220M-60,Jinko Solar Co Ltd,Mono-c-Si,0,220.0,184.5,1.6367999999999998,1.65,0.992,60.0,7.97,36.9,7.46,29.5,0.0005339899999999999,-0.1674891,47.6,1.8132242099587126,7.971043470529712,1.1550012927811546e-08,0.31839231592829587,2431.9540011100776,8.017160639373687,-0.6618,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM220M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,220.0,197.2,1.6367999999999998,1.65,0.992,60.0,7.92,37.0,7.41,29.7,0.0063676800000000006,-0.139453,46.8,1.570557969503794,7.92820066338572,4.593225410043778e-10,0.3688313243826291,356.2083747419156,-0.6584435362712826,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM220P-60,Jinko Solar Co Ltd,Multi-c-Si,0,220.0,187.0,1.6367999999999998,1.65,0.992,60.0,8.1,36.6,7.53,29.2,0.0048195,-0.16140600000000002,48.0,1.7837861354690023,8.106561847915495,9.83987599133161e-09,0.32431112752154745,400.3343884106586,9.051599032768523,-0.6053,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM220P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,220.0,197.0,1.6367999999999998,1.65,0.992,60.0,8.07,36.8,7.49,29.4,0.005649000000000001,-0.1274016,46.9,1.5429401641467522,8.086283182760871,3.4607135490796733e-10,0.38758601045476565,192.08895389255446,5.769886119286052,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM225M-60,Jinko Solar Co Ltd,Mono-c-Si,0,225.0,202.3,1.6367999999999998,1.65,0.992,60.0,8.08,37.0,7.57,29.7,0.003581864,-0.1123764,46.6,1.4931594381394016,8.08974063910419,1.3802276722743587e-10,0.38228882306551776,317.1140990397273,12.332555892239233,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM225M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,225.0,201.8,1.6367999999999998,1.65,0.992,60.0,8.02,37.2,7.53,29.9,0.006448079999999999,-0.14020680000000002,46.8,1.5772862735119617,8.025454858424709,4.5488069985754187e-10,0.360148354946954,529.5079810221523,-0.8474580105690565,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM225P-60,Jinko Solar Co Ltd,Multi-c-Si,0,225.0,200.8,1.6367999999999998,1.65,0.992,60.0,8.25,36.7,7.65,29.4,0.006088500000000001,-0.1293675,46.6,1.5796691562263214,8.26562834951315,6.562094251139545e-10,0.35564900194576526,187.7424726693876,9.153403983814894,-0.4634,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM225P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,225.0,201.6,1.6367999999999998,1.65,0.992,60.0,8.2,36.9,7.61,29.6,0.0057399999999999994,-0.1277478,46.9,1.5509412652116819,8.216087265195997,3.726315579080878e-10,0.36374358393982054,185.407386265135,6.269579651932512,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM230M-60,Jinko Solar Co Ltd,Mono-c-Si,0,230.0,206.9,1.6367999999999998,1.65,0.992,60.0,8.2,37.1,7.69,29.9,0.00363506,-0.11268012,46.6,1.4997842470451692,8.20887618449723,1.462972957989905e-10,0.3594162643444749,332.0360980838782,12.724172393294424,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM230M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,230.0,206.4,1.6367999999999998,1.65,0.992,60.0,8.16,37.4,7.67,30.0,0.00656064,-0.1409606,46.8,1.582877854722878,8.16460470190919,4.4402419073111913e-10,0.36533114874829414,647.4042566593344,-1.1844456656504398,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM230P-60,Jinko Solar Co Ltd,Multi-c-Si,0,230.0,205.4,1.6367999999999998,1.65,0.992,60.0,8.35,36.8,7.78,29.6,0.006162300000000001,-0.12972,46.6,1.583670750580407,8.36140071843571,6.647114044195512e-10,0.33426532583352875,244.8193384817447,9.14690872744439,-0.4634,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM230P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,230.0,206.2,1.6367999999999998,1.65,0.992,60.0,8.32,37.0,7.72,29.8,0.005824000000000001,-0.128094,46.9,1.5590127431116851,8.335888026604218,4.0079754122442837e-10,0.3410575302478246,178.59984079736887,6.775252680760609,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM235M-60,Jinko Solar Co Ltd,Mono-c-Si,0,235.0,211.5,1.6367999999999998,1.65,0.992,60.0,8.31,37.2,7.83,30.0,0.0036838230000000006,-0.11298384000000002,46.6,1.5007788557119948,8.315026343253606,1.417770078381162e-10,0.35276991379702705,583.2308568280197,12.300382554301848,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM235M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,235.0,211.0,1.6367999999999998,1.65,0.992,60.0,8.28,37.5,7.79,30.2,0.00665712,-0.1413375,46.8,1.5901149797449798,8.283996627849945,4.714211014268249e-10,0.3427883684373745,710.1710384608205,-0.8220424591399155,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM235P-60,Jinko Solar Co Ltd,Multi-c-Si,0,235.0,210.0,1.6367999999999998,1.65,0.992,60.0,8.47,36.9,7.89,29.8,0.006250860000000001,-0.13007249999999998,46.6,1.5919892223011947,8.48137531279828,7.144146092310671e-10,0.3123922121845185,232.6057200845444,9.663586677273065,-0.4634,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM235P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,235.0,210.8,1.6367999999999998,1.65,0.992,60.0,8.43,37.2,7.84,30.0,0.005901000000000001,-0.12878640000000002,46.9,1.5666957662009324,8.444062404301024,4.025855739715284e-10,0.33268820961222473,199.4368777667834,6.693257911313182,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM240M-60,Jinko Solar Co Ltd,Mono-c-Si,0,240.0,216.2,1.6367999999999998,1.65,0.992,60.0,8.45,37.3,7.95,30.2,0.0037458849999999996,-0.11328756,46.6,1.509248791941903,8.456345822641515,1.5471344209682354e-10,0.33022301894978634,439.71995939050737,12.948293016474482,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM240M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,240.0,215.6,1.6367999999999998,1.65,0.992,60.0,8.38,37.7,7.87,30.5,0.006737520000000001,-0.14209130000000003,46.8,1.6045550471144367,8.385476409145047,5.193990034565606e-10,0.31945678116780346,488.83289177065535,-0.12917146235187457,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM240P-60,Jinko Solar Co Ltd,Multi-c-Si,0,240.0,214.6,1.6367999999999998,1.65,0.992,60.0,8.56,37.2,8.01,30.0,0.0063172800000000015,-0.13113000000000002,46.6,1.5996392544044766,8.568033948002487,6.724521362947891e-10,0.3182880733113877,339.12927141668115,9.016299503391279,-0.4634,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM240P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,240.0,215.4,1.6367999999999998,1.65,0.992,60.0,8.54,37.4,7.95,30.2,0.005978,-0.1294788,46.9,1.5754850380790764,8.553305374441099,4.1050912147632055e-10,0.3244660299993446,208.2572248683712,6.747032266257269,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM240PP-60B,Jinko Solar Co Ltd,Multi-c-Si,0,240.0,215.4,1.6367999999999998,1.65,0.992,60.0,8.54,37.4,7.95,30.2,0.005978,-0.1294788,46.9,1.5754850380790764,8.553305374441099,4.1050912147632055e-10,0.3244660299993446,208.2572248683712,6.747032266257269,-0.4423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM245M-60,Jinko Solar Co Ltd,Mono-c-Si,0,245.0,220.8,1.6367999999999998,1.65,0.992,60.0,8.58,37.4,8.06,30.4,0.003803514,-0.11359128,46.6,1.5177668863667428,8.587536258294774,1.6857807803801918e-10,0.3087128469810157,351.46839817751277,13.599587450354024,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM245M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,245.0,220.2,1.6367999999999998,1.65,0.992,60.0,8.47,37.9,7.96,30.8,0.006809880000000001,-0.1428451,46.8,1.6168273978783447,8.474975410101068,5.54625415013528e-10,0.29722336328987475,505.985011654426,0.3168942306890776,-0.4414,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM245P-60,Jinko Solar Co Ltd,Multi-c-Si,0,245.0,224.9,1.6367999999999998,1.65,0.992,60.0,8.69,37.4,8.12,30.2,0.005024558,-0.11886094,43.0,1.5331342742859713,8.701825585832333,2.1748949018616074e-10,0.3290938954890984,241.83379511520718,10.523216757285141,-0.4324,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM245P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,245.0,221.5,1.6367999999999998,1.65,0.992,60.0,8.76,37.5,8.14,30.1,0.0049932,-0.12712500000000002,46.1,1.5404452303832548,8.777371991298233,2.293481069132964e-10,0.35226002950905155,177.63065024591904,3.9677920496563583,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM245PP-60(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,245.0,221.3,1.6367999999999998,1.65,0.992,60.0,8.76,37.5,8.14,30.1,0.0041172,-0.12375,46.1,1.5291415776673372,8.777835547374746,1.9150051370387315e-10,0.3551358075715785,174.42637783510435,5.404608152431548,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM245PP-60B,Jinko Solar Co Ltd,Multi-c-Si,0,245.0,221.5,1.6367999999999998,1.65,0.992,60.0,8.76,37.5,8.14,30.1,0.0049932,-0.12712500000000002,46.1,1.5404452303832548,8.777371991298233,2.293481069132964e-10,0.35226002950905155,177.63065024591904,3.9677920496563583,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS245P-60,Jinko Solar Co Ltd,Multi-c-Si,0,245.0,221.0,1.637,,,60.0,9.23,35.6,8.57,28.6,0.0038766000000000004,-0.11854800000000001,45.7,1.4694269880505582,9.248663053910805,2.712799471764489e-10,0.3125412901546455,154.57043518279062,7.030212265783427,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS245PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,245.0,224.9,1.6367999999999998,1.65,0.992,60.0,8.69,37.4,8.12,30.2,0.005024558,-0.11886094,43.0,1.5331342742859713,8.701825585832333,2.1748949018616074e-10,0.3290938954890984,241.83379511520718,10.523216757285141,-0.4324,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250M-60,Jinko Solar Co Ltd,Mono-c-Si,0,250.0,228.9,1.6367999999999998,1.65,0.992,60.0,8.7,37.6,8.17,30.6,0.00418992,-0.12414392,43.2,1.5497659602234513,8.70717999253191,2.499555864654057e-10,0.2949114219234458,357.3443478699037,7.645440720748682,-0.44222,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,250.0,223.3,1.9403519999999999,1.956,0.992,72.0,7.88,43.9,7.02,35.6,0.00576816,-0.1542207,47.3,1.9053681888012404,7.920670039266953,7.219426447065391e-10,0.37942722461407297,73.51570798303402,10.938493398102642,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250P-60,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,228.8,1.5397560000000001,1.614,0.954,60.0,8.85,37.7,8.2,30.5,0.00551355,-0.11536200000000002,45.1,1.5217320654385305,8.870180390675195,1.4976478839140329e-10,0.32525846868562414,142.64032913827162,11.235713744790479,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,226.1,1.6367999999999998,1.65,0.992,60.0,8.85,37.7,8.2,30.5,0.0050444999999999995,-0.12780300000000003,46.1,1.5582003363747954,8.868700619003283,2.677703788584081e-10,0.3159561865490556,149.52512798177622,5.201928481365035,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250P-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,228.8,1.5397560000000001,1.614,0.954,60.0,8.85,37.7,8.2,30.5,0.00551355,-0.11536200000000002,45.1,1.5217320654385305,8.870180390675195,1.4976478839140329e-10,0.32525846868562414,142.64032913827162,11.235713744790479,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250P-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,228.4,1.5397560000000001,1.614,0.954,60.0,8.85,37.7,8.2,30.5,0.00538965,-0.11913200000000002,45.3,1.5276517297418386,8.86993607766258,1.648883117993475e-10,0.3237426502024973,143.71546142531443,8.542355108414526,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250P-72,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,222.5,1.9403519999999999,1.956,0.992,72.0,8.11,43.5,7.2,34.7,0.00457404,-0.1193205,47.1,1.845808665465173,8.16686381411695,4.374839069383341e-10,0.46802445507543544,66.7503330315444,36.65534593823347,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,223.3,1.9403519999999999,1.956,0.992,72.0,8.09,43.7,7.18,34.8,0.006010870000000001,-0.16046640000000004,47.2,1.8903226132846698,8.146013981415853,6.844091714101165e-10,0.47043780894021453,67.94450388203586,5.388109538226494,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,228.8,1.5397560000000001,1.614,0.954,60.0,8.85,37.7,8.2,30.5,0.00551355,-0.11536200000000002,45.1,1.5217320654385305,8.870180390675195,1.4976478839140329e-10,0.32525846868562414,142.64032913827162,11.235713744790479,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250PP-60(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,250.0,226.0,1.6367999999999998,1.65,0.992,60.0,8.85,37.7,8.2,30.5,0.0041595,-0.12441000000000002,46.1,1.546657912019732,8.869162445646797,2.23447611162036e-10,0.3188911635995268,147.27697189750222,6.648634903711269,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250PP-60B,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,226.1,1.6367999999999998,1.65,0.992,60.0,8.85,37.7,8.2,30.5,0.0050444999999999995,-0.12780300000000003,46.1,1.5582003363747954,8.868700619003283,2.677703788584081e-10,0.3159561865490556,149.52512798177622,5.201928481365035,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,228.8,1.5397560000000001,1.614,0.954,60.0,8.85,37.7,8.2,30.5,0.00551355,-0.11536200000000002,45.1,1.5217320654385305,8.870180390675195,1.4976478839140329e-10,0.32525846868562414,142.64032913827162,11.235713744790479,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM250PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,228.4,1.5397560000000001,1.614,0.954,60.0,8.85,37.7,8.2,30.5,0.00538965,-0.11913200000000002,45.3,1.5276517297418386,8.86993607766258,1.648883117993475e-10,0.3237426502024973,143.71546142531443,8.542355108414526,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS250P-60,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,225.6,1.637,,,60.0,9.32,35.8,8.63,29.0,0.0039144,-0.119214,45.7,1.4869836313470985,9.33970883090569,3.174005430673623e-10,0.27840580678741067,131.65379160255998,8.321136956555392,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS250PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,250.0,227.8,1.5811,1.63,0.97,60.0,8.85,37.7,8.2,30.5,0.00561975,-0.12252500000000002,45.1,1.552119393064338,8.868943175093918,2.435037600884632e-10,0.3175013712651696,148.3324366957837,8.851862129297578,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255M-60,Jinko Solar Co Ltd,Mono-c-Si,0,255.0,230.4,1.620984,1.644,0.986,60.0,8.96,37.8,8.28,30.8,0.006702080000000002,-0.15479099999999998,46.5,1.6167894545621777,8.977629378197705,6.108943429994724e-10,0.2699831441212475,137.21693610675433,-7.323291510269065,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,255.0,227.9,1.9403519999999999,1.956,0.992,72.0,7.94,44.4,7.14,35.7,0.005812080000000001,-0.1559772,47.3,1.9061539693385965,7.97941671571629,5.720095070100188e-10,0.4340592212017083,87.43575952383198,8.759793670099368,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255P-60,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,233.5,1.5397560000000001,1.614,0.954,60.0,8.92,38.0,8.28,30.8,0.00555716,-0.11628,45.1,1.5339834440079727,8.938418265322179,1.51594969718816e-10,0.31722763079624994,153.633935732547,11.268158713100046,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,230.8,1.6367999999999998,1.65,0.992,60.0,8.92,38.0,8.28,30.8,0.0050844,-0.12882000000000002,46.1,1.5707500201134832,8.93699413838776,2.710481540364185e-10,0.30793017208023427,161.62851450568067,5.232883672566917,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255P-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,233.5,1.5397560000000001,1.614,0.954,60.0,8.92,38.0,8.28,30.8,0.00555716,-0.11628,45.1,1.5339834440079727,8.938418265322179,1.51594969718816e-10,0.31722763079624994,153.633935732547,11.268158713100046,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255P-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,233.1,1.5397560000000001,1.614,0.954,60.0,8.92,38.0,8.28,30.8,0.00543228,-0.12008,45.3,1.5399525500080196,8.93818294868175,1.6690664821940247e-10,0.31571233729817777,154.87885012821633,8.574218217899729,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255P-72,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,227.1,1.9403519999999999,1.956,0.992,72.0,8.2,43.7,7.31,34.9,0.004624799999999999,-0.1198691,47.1,1.8512720781140855,8.253130468205606,4.277297688369508e-10,0.4587371578623142,70.80014579184491,36.26834645606942,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,227.9,1.9403519999999999,1.956,0.992,72.0,8.12,43.9,7.29,35.0,0.00603316,-0.1612008,47.2,1.8873695438701843,8.165568054287647,6.042713433424005e-10,0.4653025301889256,82.91459718858316,4.266305170667077,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,233.5,1.5397560000000001,1.614,0.954,60.0,8.92,38.0,8.28,30.8,0.00555716,-0.11628,45.1,1.5339834440079727,8.938418265322179,1.51594969718816e-10,0.31722763079624994,153.633935732547,11.268158713100046,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255PP-60(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,255.0,230.6,1.6367999999999998,1.65,0.992,60.0,8.92,38.0,8.28,30.8,0.0041924,-0.1254,46.1,1.5591077723344415,8.937438578140132,2.261623164282465e-10,0.31086499596690376,159.01043730769499,6.678873534604737,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255PP-60B,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,230.8,1.6367999999999998,1.65,0.992,60.0,8.92,38.0,8.28,30.8,0.0050844,-0.12882000000000002,46.1,1.5707500201134832,8.93699413838776,2.710481540364185e-10,0.30793017208023427,161.62851450568067,5.232883672566917,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,233.5,1.5397560000000001,1.614,0.954,60.0,8.92,38.0,8.28,30.8,0.00555716,-0.11628,45.1,1.5339834440079727,8.938418265322179,1.51594969718816e-10,0.31722763079624994,153.633935732547,11.268158713100046,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM255PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,233.1,1.5397560000000001,1.614,0.954,60.0,8.92,38.0,8.28,30.8,0.00543228,-0.12008,45.3,1.5399525500080196,8.93818294868175,1.6690664821940247e-10,0.31571233729817777,154.87885012821633,8.574218217899729,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS255P-60,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,230.3,1.637,,,60.0,9.39,36.1,8.72,29.3,0.003943800000000001,-0.12021300000000001,45.7,1.4987861659205008,9.407034257012322,3.174467748712104e-10,0.27113899683981796,149.46324980889094,8.247250500856966,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS255PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,255.0,232.5,1.5811,1.63,0.97,60.0,8.92,38.0,8.28,30.8,0.0056642,-0.12350000000000001,45.1,1.5646196413042228,8.93722742257257,2.4648488876848593e-10,0.3094744844953894,160.23944399112202,8.88400957943576,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,260.0,234.8,1.6367999999999998,1.65,0.992,60.0,9.1,38.0,8.42,30.9,0.003003,-0.12274,45.9,1.564520678238615,9.119692647821187,2.49969950534206e-10,0.29054063857625123,134.25924149097517,9.893378941361673,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,260.0,232.5,1.9403519999999999,1.956,0.992,72.0,8.01,44.8,7.24,35.9,0.005863320000000001,-0.15738239999999998,47.3,1.9135790301277302,8.047386918706323,5.159075309646401e-10,0.4549292746482383,97.46681201380721,7.758341301905393,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260P-60,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,238.2,1.5397560000000001,1.614,0.954,60.0,8.98,38.1,8.37,31.1,0.00559454,-0.116586,45.1,1.5408161868150412,8.994028303668783,1.602880513646826e-10,0.28546300868225144,182.73470764752528,11.697603565190807,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,235.4,1.6367999999999998,1.65,0.992,60.0,8.98,38.1,8.37,31.1,0.0051186,-0.12915900000000002,46.1,1.577850926544028,8.992778460326662,2.8674751446030033e-10,0.27615638819692767,194.0675473041327,5.643719304248775,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260P-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,238.2,1.5397560000000001,1.614,0.954,60.0,8.98,38.1,8.37,31.1,0.00559454,-0.116586,45.1,1.5408161868150412,8.994028303668783,1.602880513646826e-10,0.28546300868225144,182.73470764752528,11.697603565190807,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260P-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,237.8,1.5397560000000001,1.614,0.954,60.0,8.98,38.1,8.37,31.1,0.005468820000000001,-0.120396,45.3,1.5468433904033525,8.993820845399087,1.7653565520222095e-10,0.28394254713235934,184.4897425855686,8.996083980549754,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260P-72,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,231.6,1.9403519999999999,1.956,0.992,72.0,8.3,43.9,7.43,35.0,0.0046812,-0.12041769999999999,47.1,1.8536238995071652,8.351105632048146,4.02605321647663e-10,0.4651746819070038,75.54842624688273,35.4507846587557,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,232.5,1.9403519999999999,1.956,0.992,72.0,8.2,44.0,7.39,35.2,0.006092599999999999,-0.16156800000000002,47.2,1.8915082221221864,8.241002009669819,6.115983609716789e-10,0.44265247469501035,88.52616338900468,4.276916498965416,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,238.2,1.5397560000000001,1.614,0.954,60.0,8.98,38.1,8.37,31.1,0.00559454,-0.116586,45.1,1.5408161868150412,8.994028303668783,1.602880513646826e-10,0.28546300868225144,182.73470764752528,11.697603565190807,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260PP-60(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,260.0,235.3,1.6367999999999998,1.65,0.992,60.0,8.98,38.1,8.37,31.1,0.004220600000000001,-0.12573,46.1,1.5661107746378047,8.993168252923583,2.391748030527586e-10,0.2790973554853366,190.32854599793515,7.090710401074419,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260PP-60B,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,235.4,1.6367999999999998,1.65,0.992,60.0,8.98,38.1,8.37,31.1,0.0051186,-0.12915900000000002,46.1,1.577850926544028,8.992778460326662,2.8674751446030033e-10,0.27615638819692767,194.0675473041327,5.643719304248775,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,238.2,1.5397560000000001,1.614,0.954,60.0,8.98,38.1,8.37,31.1,0.00559454,-0.116586,45.1,1.5408161868150412,8.994028303668783,1.602880513646826e-10,0.28546300868225144,182.73470764752528,11.697603565190807,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM260PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,237.8,1.5397560000000001,1.614,0.954,60.0,8.98,38.1,8.37,31.1,0.005468820000000001,-0.120396,45.3,1.5468433904033525,8.993820845399087,1.7653565520222095e-10,0.28394254713235934,184.4897425855686,8.996083980549754,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS260M-60,Jinko Solar Co Ltd,Mono-c-Si,0,260.0,235.5,1.6367999999999998,1.65,0.992,60.0,9.1,38.0,8.42,30.9,0.005369,-0.12996000000000002,45.6,1.594305471652652,9.118519057076742,3.9389685220780216e-10,0.2831495318629583,139.13564553625415,7.312648885673716,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS260M-60B-MX,Jinko Solar Co Ltd,Mono-c-Si,0,260.0,236.4,1.58,,,60.0,12.0,35.0,8.86,29.4,0.008280000000000001,-0.1078,46.2,1.7270689179279517,12.011922009940857,1.3745194309213031e-08,0.010489542681545753,10.5581629070198,56.77641301881175,-0.417,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jinko Solar Co Ltd JKMS260P-60,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,234.9,1.637,,,60.0,9.45,36.2,8.81,29.5,0.003969,-0.12054600000000003,45.7,1.5032751499296162,9.463319880292604,3.225574584583518e-10,0.2545588668934325,180.60083646722472,8.318041201598133,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS260PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,260.0,237.2,1.5811,1.63,0.97,60.0,8.98,38.1,8.37,31.1,0.0057023,-0.123825,45.1,1.5716613716374086,8.992983226019867,2.606813664415539e-10,0.27770583857744285,192.07850208581993,9.307024697349995,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,265.0,239.4,1.6367999999999998,1.65,0.992,60.0,9.19,38.2,8.5,31.2,0.0030327,-0.12338600000000002,45.9,1.5770859667657797,9.209078000233891,2.6959653005697354e-10,0.2701389480693902,130.12774052307185,10.479212172055792,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,265.0,237.0,1.9403519999999999,1.956,0.992,72.0,8.06,45.1,7.36,36.0,0.00589992,-0.1584363,47.3,1.910671775290406,8.090528391892374,4.337025397338913e-10,0.47886875737652596,126.42927791921765,6.16595078892247,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265P-60,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,242.9,1.5397560000000001,1.614,0.954,60.0,9.03,38.6,8.44,31.4,0.005625689999999999,-0.118116,45.1,1.555801662641786,9.042422815039076,1.4885997223180077e-10,0.30285061258690055,220.13860954359674,10.970665547699818,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265P-60B,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,240.1,1.6367999999999998,1.65,0.992,60.0,9.03,38.6,8.44,31.4,0.0051471,-0.13085400000000003,46.1,1.5930012950127677,9.041195259022194,2.6603542962323914e-10,0.29361005814658103,236.8233811806458,4.948182444922685,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265P-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,242.9,1.5397560000000001,1.614,0.954,60.0,9.03,38.6,8.44,31.4,0.005625689999999999,-0.118116,45.1,1.555801662641786,9.042422815039076,1.4885997223180077e-10,0.30285061258690055,220.13860954359674,10.970665547699818,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265P-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,242.5,1.5397560000000001,1.614,0.954,60.0,9.03,38.6,8.44,31.4,0.00549927,-0.121976,45.3,1.561832489327913,9.042219814212373,1.6385983999788043e-10,0.3013467482935302,222.6843472554732,8.282256467883306,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265P-72,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,236.2,1.9403519999999999,1.956,0.992,72.0,8.42,44.1,7.55,35.1,0.00474888,-0.1209663,47.1,1.8585423260513632,8.471269171326753,3.91356926174476e-10,0.4701081286601194,77.20644911739876,34.975457588330144,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,237.1,1.9403519999999999,1.956,0.992,72.0,8.26,44.2,7.51,35.3,0.00613718,-0.16230240000000004,47.2,1.8883964800363697,8.2944785604883,5.391693807096356e-10,0.45185652577795865,108.25090180483312,3.129012067062063,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,242.9,1.5397560000000001,1.614,0.954,60.0,9.03,38.6,8.44,31.4,0.005625689999999999,-0.118116,45.1,1.555801662641786,9.042422815039076,1.4885997223180077e-10,0.30285061258690055,220.13860954359674,10.970665547699818,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265PP-60(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,265.0,239.9,1.6367999999999998,1.65,0.992,60.0,9.03,38.6,8.44,31.4,0.0042441,-0.12738000000000002,46.1,1.5812054418424188,9.041578180209475,2.2195341170202612e-10,0.2965310292800069,231.26911385608412,6.388709897576986,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265PP-60B,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,240.1,1.6367999999999998,1.65,0.992,60.0,9.03,38.6,8.44,31.4,0.0051471,-0.13085400000000003,46.1,1.5930012950127677,9.041195259022194,2.6603542962323914e-10,0.29361005814658103,236.8233811806458,4.948182444922685,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,242.9,1.5397560000000001,1.614,0.954,60.0,9.03,38.6,8.44,31.4,0.005625689999999999,-0.118116,45.1,1.555801662641786,9.042422815039076,1.4885997223180077e-10,0.30285061258690055,220.13860954359674,10.970665547699818,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM265PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,242.5,1.5397560000000001,1.614,0.954,60.0,9.03,38.6,8.44,31.4,0.00549927,-0.121976,45.3,1.561832489327913,9.042219814212373,1.6385983999788043e-10,0.3013467482935302,222.6843472554732,8.282256467883306,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS265M-60,Jinko Solar Co Ltd,Mono-c-Si,0,265.0,240.2,1.6367999999999998,1.65,0.992,60.0,9.19,38.2,8.5,31.2,0.005422099999999999,-0.13064400000000004,45.6,1.6072125460516633,9.207926304792448,4.2493632256306884e-10,0.2627076809014976,134.67827392465077,7.890135784652975,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS265M-60B-MX,Jinko Solar Co Ltd,Mono-c-Si,0,265.0,241.1,1.58,,,60.0,12.0,35.0,8.96,29.6,0.008280000000000001,-0.1078,46.2,1.6794457827289437,12.001088111825664,7.853173272294689e-09,0.0009999900004193695,11.028168558005476,49.64276859911898,-0.417,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS265P-60,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,239.5,1.637,,,60.0,9.51,36.7,8.88,29.8,0.003994200000000001,-0.12221100000000003,45.7,1.51959202588643,9.522592688214383,3.032166038262414e-10,0.2708461898677242,204.54310451804838,7.717606652023481,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS265PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,241.9,1.5811,1.63,0.97,60.0,9.03,38.6,8.44,31.4,0.005734049999999999,-0.12545,45.1,1.5868171571259713,9.041395273767883,2.420121591572392e-10,0.2951403608680402,233.87921693525246,8.592491419396534,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS265PP-60-MX,Jinko Solar Co Ltd,Multi-c-Si,0,265.0,241.6,1.58,,,60.0,12.0,35.0,8.88,29.8,0.0078,-0.11375000000000002,45.3,1.5725313900392734,12.001127214223303,1.879524748266479e-09,0.0009999900004604848,10.645607470546512,26.108295199223083,-0.426,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM270M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,244.1,1.6367999999999998,1.65,0.992,60.0,9.28,38.4,8.6,31.4,0.0030624,-0.124032,45.9,1.584718830687734,9.297543951238827,2.702468180797043e-10,0.26412356738032833,139.71008078755352,10.406878933148361,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,247.9,1.58,,,60.0,9.28,38.4,8.6,31.4,0.0061248,-0.119808,45.1,1.5506380179228005,9.298844151676507,1.5848426920154525e-10,0.27250195766324087,134.19644909901677,9.118723266707168,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270M-72,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,242.9,1.9403519999999999,1.956,0.992,72.0,8.35,45.0,7.52,35.9,0.0037015550000000005,-0.136674,46.6,1.8478832671833914,8.3979070864801,2.087465619947475e-10,0.48351387796919154,84.27440106443025,15.981281686189334,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,241.6,1.9403519999999999,1.956,0.992,72.0,8.09,45.2,7.48,36.1,0.00592188,-0.1587876,47.3,1.9024333897179557,8.109595415644481,3.7850155072152573e-10,0.4754765567969603,196.3013133787345,4.931956454376062,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270P-60,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,247.6,1.5397560000000001,1.614,0.954,60.0,9.09,38.8,8.52,31.7,0.00566307,-0.11872799999999999,45.1,1.5653664163184475,9.099855791921408,1.539028368034949e-10,0.28370671680480974,261.6628109513692,11.201263731636615,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270P-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,247.6,1.5397560000000001,1.614,0.954,60.0,9.09,38.8,8.52,31.7,0.00566307,-0.11872799999999999,45.1,1.5653664163184475,9.099855791921408,1.539028368034949e-10,0.28370671680480974,261.6628109513692,11.201263731636615,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270P-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,247.2,1.5397560000000001,1.614,0.954,60.0,9.09,38.8,8.52,31.7,0.0055358099999999995,-0.12260799999999998,45.3,1.571451308062493,9.099670751776458,1.6944054181068591e-10,0.28219954593093216,265.2528073100474,8.508774809138918,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270P-72,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,240.8,1.9403519999999999,1.956,0.992,72.0,8.59,44.2,7.67,35.2,0.00484476,-0.12124060000000002,47.1,1.8677134926751988,8.645987865760898,4.2299679864198026e-10,0.45847859743330804,70.34258787620504,35.625683583713275,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,241.6,1.9403519999999999,1.956,0.992,72.0,8.32,44.3,7.63,35.4,0.006181760000000001,-0.16266960000000003,47.2,1.884093973648076,8.346948994015651,4.93279439506349e-10,0.447037630365021,138.01455833336763,2.303309240725921,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,247.6,1.5397560000000001,1.614,0.954,60.0,9.09,38.8,8.52,31.7,0.00566307,-0.11872799999999999,45.1,1.5653664163184475,9.099855791921408,1.539028368034949e-10,0.28370671680480974,261.6628109513692,11.201263731636615,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,247.6,1.5397560000000001,1.614,0.954,60.0,9.09,38.8,8.52,31.7,0.00566307,-0.11872799999999999,45.1,1.5653664163184475,9.099855791921408,1.539028368034949e-10,0.28370671680480974,261.6628109513692,11.201263731636615,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM270PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,247.2,1.5397560000000001,1.614,0.954,60.0,9.09,38.8,8.52,31.7,0.0055358099999999995,-0.12260799999999998,45.3,1.571451308062493,9.099670751776458,1.6944054181068591e-10,0.28219954593093216,265.2528073100474,8.508774809138918,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS270M-60,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,247.4,1.5397560000000001,1.614,0.954,60.0,9.28,38.4,8.6,31.4,0.00531744,-0.126336,45.0,1.5689771283130252,9.2981380405055,2.1181374206818868e-10,0.26798475049539,137.10955117642507,5.989278512673781,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS270M-60B-MX,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,245.8,1.58,,,60.0,12.0,35.0,9.07,29.8,0.008280000000000001,-0.1078,46.2,1.59749660537473,12.001039849627007,2.739188188136992e-09,0.0009999900004177469,11.540014949432152,37.20691059248154,-0.417,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS270M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,247.4,1.5397560000000001,1.614,0.954,60.0,9.28,38.4,8.6,31.4,0.00531744,-0.126336,45.0,1.5689771283130252,9.2981380405055,2.1181374206818868e-10,0.26798475049539,137.10955117642507,5.989278512673781,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS270M-60-MX,Jinko Solar Co Ltd,Mono-c-Si,0,270.0,247.7,1.58,,,60.0,12.0,35.0,9.07,29.8,0.0078,-0.1078,44.9,1.5974966053747186,12.001039849627015,2.7391881881365378e-09,0.0009999900004235144,11.54001494943222,37.256923157346506,-0.409,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS270PP-60-MX,Jinko Solar Co Ltd,Multi-c-Si,0,270.0,246.3,1.58,,,60.0,12.0,35.0,8.97,30.1,0.0078,-0.11375000000000002,45.3,1.4462136131852108,12.001088500809784,2.724963794997747e-10,0.0009999900110878688,11.024227085652196,7.8582288644763425,-0.426,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM275M-60,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,252.5,1.5397560000000001,1.614,0.954,60.0,9.4,38.5,8.7,31.6,0.0081498,-0.11935,44.9,1.600443160097617,9.417477910322694,3.2572301779395573e-10,0.24357968402105568,131.0024552808617,16.050523043625716,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,250.6,1.5397560000000001,1.614,0.954,60.0,9.4,38.5,8.7,31.6,0.0064860000000000004,-0.11858,46.2,1.5880628162186154,9.417938914745392,2.699170530597468e-10,0.2465844489256771,129.2103768835241,15.25771482732053,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275M-60B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,250.6,1.5397560000000001,1.614,0.954,60.0,9.4,38.5,8.7,31.6,0.0064860000000000004,-0.11858,46.2,1.5880628162186154,9.417938914745392,2.699170530597468e-10,0.2465844489256771,129.2103768835241,15.25771482732053,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,252.5,1.5397560000000001,1.614,0.954,60.0,9.4,38.5,8.7,31.6,0.0081498,-0.11935,44.9,1.600443160097617,9.417477910322694,3.2572301779395573e-10,0.24357968402105568,131.0024552808617,16.050523043625716,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,252.7,1.58,,,60.0,9.4,38.5,8.7,31.6,0.006204,-0.12012,45.1,1.5590474889796664,9.419046210722854,1.7174230166043764e-10,0.2536622461949199,125.1915788743082,9.721822928348384,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275M-72,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,247.5,1.9403519999999999,1.956,0.992,72.0,8.37,45.3,7.61,36.1,0.0037104209999999998,-0.13758515999999998,46.6,1.8493815387267971,8.409505101783981,1.8357812579714891e-10,0.4919185473657626,104.22346010190307,14.72964584501592,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,246.2,1.9403519999999999,1.956,0.992,72.0,8.19,45.4,7.58,36.3,0.00599508,-0.1594902,47.3,1.9110883512417884,8.208775467825255,3.8471810259300293e-10,0.46546682738839656,203.04015046934438,4.963451760557061,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275P-60,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.2,1.54,1.614,0.954,60.0,9.15,39.1,8.61,32.0,0.005947500000000001,-0.12707500000000002,45.3,1.6109876131495624,9.155910388837658,2.609318057174552e-10,0.2682711748440362,415.31643434823366,9.098031939196677,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275P-72,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,245.4,1.9403519999999999,1.956,0.992,72.0,8.7,44.4,7.77,35.4,0.004906799999999999,-0.1217892,47.1,1.8771838028600458,8.755746883558595,4.3401167025998005e-10,0.44849409359756076,69.99312920189334,35.768252888878486,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,246.2,1.9403519999999999,1.956,0.992,72.0,8.41,44.5,7.73,35.6,0.006248630000000001,-0.16340400000000002,47.2,1.8915106730126237,8.434938599623681,4.931824115912388e-10,0.4381844428669855,147.76818602159915,2.2064708607170607,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.2,1.54,1.614,0.954,60.0,9.15,39.1,8.61,32.0,0.005947500000000001,-0.12707500000000002,45.3,1.6109876131495624,9.155910388837658,2.609318057174552e-10,0.2682711748440362,415.31643434823366,9.098031939196677,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,252.1,1.59,,,120.0,9.15,39.1,8.61,32.0,0.0055815000000000005,-0.127466,45.4,1.5691619255311593,9.157035189936607,1.3644551401621914e-10,0.27849927144298736,362.21744218684796,3.2642175756203633,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.8,1.59,,,120.0,9.15,39.1,8.61,32.0,0.0057645000000000005,-0.133331,45.4,1.5844156050233382,9.156616797169367,1.735259100424056e-10,0.2747570125480109,379.94619638800935,0.5953601322955706,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.2,1.54,1.614,0.954,60.0,9.15,39.1,8.61,32.0,0.005947500000000001,-0.12707500000000002,45.3,1.6109876131495624,9.155910388837658,2.609318057174552e-10,0.2682711748440362,415.31643434823366,9.098031939196677,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM275PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,250.8,1.58,,,60.0,9.15,39.1,8.61,32.0,0.006954000000000001,-0.127466,45.3,1.6307185333003404,9.155404113835509,3.502284810098796e-10,0.26348205900211286,446.11594838280206,11.24897167002519,-0.429,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS275M-60,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,252.1,1.5397560000000001,1.614,0.954,60.0,9.4,38.5,8.7,31.6,0.0053862,-0.126665,45.0,1.5775692728014534,9.41833501166246,2.2964139605056912e-10,0.24913837223704566,127.72835066823448,6.578332337616901,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS275M-60B-MX,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,250.4,1.58,,,60.0,12.0,35.0,9.17,30.0,0.008280000000000001,-0.1078,46.2,1.5150904527744604,12.0009971415587,8.434960804230425e-10,0.0009999900007778817,12.034279366776852,24.645882082818208,-0.417,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS275M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,252.1,1.5397560000000001,1.614,0.954,60.0,9.4,38.5,8.7,31.6,0.0053862,-0.126665,45.0,1.5775692728014534,9.41833501166246,2.2964139605056912e-10,0.24913837223704566,127.72835066823448,6.578332337616901,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS275M-60-MX,Jinko Solar Co Ltd,Mono-c-Si,0,275.0,252.4,1.58,,,60.0,12.0,35.0,9.17,30.0,0.0078,-0.1078,44.9,1.5150904527746254,12.000997141558685,8.434960804251474e-10,0.000999990000731043,12.03427936677619,24.702093518722513,-0.409,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS275PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.8,1.5397560000000001,1.614,0.954,60.0,9.58,37.2,9.06,30.5,0.0065144,-0.12276000000000002,45.2,1.5222711221665177,9.582638884676689,2.325994776473074e-10,0.23896182952423548,867.5085549718915,5.991354162881882,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS275PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.8,1.5397560000000001,1.614,0.954,60.0,9.58,37.2,9.06,30.5,0.0065144,-0.12276000000000002,45.2,1.5222711221665177,9.582638884676689,2.325994776473074e-10,0.23896182952423548,867.5085549718915,5.991354162881882,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS275PP-60-MX,Jinko Solar Co Ltd,Multi-c-Si,0,275.0,251.0,1.58,,,60.0,12.0,35.0,9.06,30.5,0.0078,-0.11375000000000002,45.3,1.9611161055827226,12.00093231384825,9.99999917628003e-08,0.0009999905802819595,12.871089362508302,-91.33053226908373,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,257.2,1.5397560000000001,1.614,0.954,60.0,9.53,38.6,8.81,31.8,0.008262509999999999,-0.11966,44.9,1.6089977590066333,9.547464865997048,3.5203143225092444e-10,0.224981680424058,122.76507204943479,16.66077949810526,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,255.3,1.5397560000000001,1.614,0.954,60.0,9.53,38.6,8.81,31.8,0.0065757,-0.11888800000000001,46.2,1.5965515351932087,9.547926858365614,2.9187016291963787e-10,0.2279738968947027,121.19197258451734,15.866743024357374,-0.417,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jinko Solar Co Ltd JKM280M-60B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,255.3,1.5397560000000001,1.614,0.954,60.0,9.53,38.6,8.81,31.8,0.0065757,-0.11888800000000001,46.2,1.5965515351932087,9.547926858365614,2.9187016291963787e-10,0.2279738968947027,121.19197258451734,15.866743024357374,-0.417,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jinko Solar Co Ltd JKM280M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,257.2,1.59,,,120.0,9.49,38.6,8.81,31.8,0.005693999999999999,-0.130468,45.0,1.5697389447835703,9.505941120202559,1.931420684874231e-10,0.23514816989775497,139.98741549582425,2.162404591639869,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,257.1,1.59,,,120.0,9.49,38.6,8.81,31.8,0.004745,-0.125064,45.3,1.544163351751864,9.506862972466667,1.2842323403188867e-10,0.24135451554443613,135.8274418393153,3.2864026659447574,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,256.7,1.59,,,120.0,9.49,38.6,8.81,31.8,0.006737899999999999,-0.13239800000000002,45.3,1.5926154207579006,9.505141181958109,2.7516485998674887e-10,0.2296296573258994,143.92440233406597,3.4427266443476343,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,256.9,1.59,,,120.0,9.49,38.6,8.81,31.8,0.0058838,-0.128924,45.2,1.5748020051453677,9.505762082735751,2.0906512115916677e-10,0.23392414951397594,140.8405416465676,4.0332468825517624,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,257.2,1.5397560000000001,1.614,0.954,60.0,9.53,38.6,8.81,31.8,0.008262509999999999,-0.11966,44.9,1.6089977590066333,9.547464865997048,3.5203143225092444e-10,0.224981680424058,122.76507204943479,16.66077949810526,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,257.4,1.58,,,60.0,9.49,38.6,8.81,31.8,0.0062634000000000006,-0.120432,45.1,1.5638362580582086,9.506151285743877,1.7598921372544648e-10,0.23657709134683982,139.0054458055414,9.844599201143513,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-72,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,252.1,1.9403519999999999,1.956,0.992,72.0,8.39,45.4,7.71,36.3,0.0037192870000000004,-0.13788888,46.6,1.8464652144402687,8.418387576697283,1.697975119721121e-10,0.4733317694070869,139.8940724661356,13.950652984325469,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,250.8,1.9403519999999999,1.956,0.992,72.0,8.24,45.6,7.65,36.6,0.00603168,-0.1601928,47.3,1.9206677749439953,8.255653727371033,3.939436634535773e-10,0.4430485500110058,233.21733465856192,5.10535594300144,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280P-60,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,255.9,1.54,1.614,0.954,60.0,9.2,39.4,8.69,32.3,0.00598,-0.12805,45.3,1.6216642019195577,9.203205406509142,2.569373994671396e-10,0.26189121233061025,751.6674738995324,8.900723932046363,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280P-72,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,250.0,1.9403519999999999,1.956,0.992,72.0,8.81,44.5,7.89,35.5,0.00496884,-0.12206349999999999,47.1,1.8791691806624502,8.863450885837423,4.286778590848693e-10,0.44099322455049356,72.68636301761231,35.48362615212586,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,250.8,1.9403519999999999,1.956,0.992,72.0,8.48,44.7,7.83,35.8,0.006300640000000001,-0.16413840000000005,47.2,1.8964758320705617,8.500864210713013,4.785001207088445e-10,0.43070433838409455,175.0544667564754,1.8750297627633092,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,255.9,1.54,1.614,0.954,60.0,9.2,39.4,8.69,32.3,0.00598,-0.12805,45.3,1.6216642019195577,9.203205406509142,2.569373994671396e-10,0.26189121233061025,751.6674738995324,8.900723932046363,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,256.8,1.59,,,120.0,9.2,39.4,8.69,32.3,0.005612,-0.128444,45.4,1.5795801053874245,9.20421246152616,1.3430524222263104e-10,0.2720924462958015,594.2489278540972,3.0742412954855554,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,256.5,1.59,,,120.0,9.2,39.4,8.69,32.3,0.005796,-0.13435400000000003,45.4,1.594911712392809,9.203837524112698,1.7078473203987039e-10,0.2683639786051896,643.3702908609544,0.4096174867082479,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,255.9,1.54,1.614,0.954,60.0,9.2,39.4,8.69,32.3,0.00598,-0.12805,45.3,1.6216642019195577,9.203205406509142,2.569373994671396e-10,0.26189121233061025,751.6674738995324,8.900723932046363,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM280PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,255.5,1.58,,,60.0,9.2,39.4,8.69,32.3,0.006992,-0.128444,45.3,1.6415217601606973,9.20275421720607,3.44952891166249e-10,0.2571135292981088,858.8449087289388,11.050057030719406,-0.429,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS280M-60,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,256.8,1.5397560000000001,1.614,0.954,60.0,9.53,38.6,8.81,31.8,0.00546069,-0.126994,45.0,1.586080093240955,9.54832090977212,2.487280110829458e-10,0.23049832718299712,119.89847527646533,7.154256559010077,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS280M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,280.0,256.8,1.5397560000000001,1.614,0.954,60.0,9.53,38.6,8.81,31.8,0.00546069,-0.126994,45.0,1.586080093240955,9.54832090977212,2.487280110829458e-10,0.23049832718299712,119.89847527646533,7.154256559010077,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS280PP-60-MX,Jinko Solar Co Ltd,Multi-c-Si,0,280.0,255.7,1.58,,,60.0,12.0,35.0,9.15,30.7,0.0078,-0.11375000000000002,45.3,1.946488258777308,12.000872088326325,8.710145698555116e-08,0.0009999901824797196,13.759947517256888,-99.9999997321658,-0.426,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM285M-60,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,262.0,1.5397560000000001,1.614,0.954,60.0,9.54,38.7,8.9,32.0,0.00827118,-0.11997000000000001,44.9,1.6086419109221481,9.550964808183494,3.328865683025851e-10,0.21116627205424415,183.72655084238642,16.090901529634653,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,260.0,1.5397560000000001,1.614,0.954,60.0,9.54,38.7,8.9,32.0,0.0065826,-0.119196,46.2,1.5961779303966352,9.551335679470233,2.757638705261894e-10,0.21413447535029279,180.21354856847873,15.292779660826643,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,260.0,1.5397560000000001,1.614,0.954,60.0,9.54,38.7,8.9,32.0,0.0065826,-0.119196,46.2,1.5961779303966352,9.551335679470233,2.757638705261894e-10,0.21413447535029279,180.21354856847873,15.292779660826643,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.9,1.59,,,120.0,9.51,38.7,8.9,32.0,0.005706,-0.130806,45.0,1.5702405283436784,9.520031413685052,1.8473209930192188e-10,0.2208493660749276,209.37004944991673,1.7525150957197027,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.8,1.59,,,120.0,9.51,38.7,8.9,32.0,0.0047550000000000005,-0.125388,45.3,1.5447083695149904,9.520782164608121,1.2281921770667221e-10,0.22698835647014093,200.2064813066422,2.8703855720038924,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.4,1.59,,,120.0,9.51,38.7,8.9,32.0,0.0067521,-0.13274100000000003,45.3,1.5930956609293077,9.51938300100732,2.632821390312306e-10,0.21538652005467282,218.30179430851575,3.031224588131687,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.6,1.59,,,120.0,9.51,38.7,8.9,32.0,0.0058962,-0.129258,45.2,1.5753099622286275,9.51988567450532,2.0001306787603264e-10,0.21963503709735782,211.28849819606296,3.617952043255141,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,262.0,1.5397560000000001,1.614,0.954,60.0,9.54,38.7,8.9,32.0,0.00827118,-0.11997000000000001,44.9,1.6086419109221481,9.550964808183494,3.328865683025851e-10,0.21116627205424415,183.72655084238642,16.090901529634653,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,262.1,1.58,,,60.0,9.51,38.7,8.9,32.0,0.0062766,-0.120744,45.1,1.5644124785037943,9.520200318122704,1.6849436928513886e-10,0.22224727530667607,207.20644709535748,9.412106421535963,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-72,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,256.7,1.9403519999999999,1.956,0.992,72.0,8.41,45.5,7.74,36.8,0.0037281530000000005,-0.1381926,46.6,1.8612173448886133,8.433993774621229,1.9609301969996363e-10,0.40922762627939474,143.43739332128527,15.25735886308964,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,255.4,1.9403519999999999,1.956,0.992,72.0,8.29,45.9,7.72,36.9,0.006068279999999999,-0.16124670000000002,47.3,1.931948403128901,8.30300569903847,3.911421085200785e-10,0.4343486217698856,276.85944861505254,4.9841352565472485,-0.4405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285P-60,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,260.6,1.54,1.614,0.954,60.0,9.26,39.7,8.76,32.6,0.006019,-0.129025,45.3,1.63423798544359,9.262186457389568,2.599056269151937e-10,0.25510267449918494,1080.4014237873137,8.93956002950294,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285P-72,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,254.6,1.9403519999999999,1.956,0.992,72.0,8.85,44.7,7.92,36.0,0.0049914,-0.12261210000000002,47.1,1.898809574603308,8.898366956206447,4.94121858688772e-10,0.38975983817684706,71.31676292911982,37.01131295562668,-0.4575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,255.4,1.9403519999999999,1.956,0.992,72.0,8.55,44.9,7.9,36.1,0.0063526500000000005,-0.1648728,47.2,1.908749047332409,8.569677270318243,5.057267280859976e-10,0.40806723892743973,177.30992646458554,2.264780932804472,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,260.6,1.54,1.614,0.954,60.0,9.26,39.7,8.76,32.6,0.006019,-0.129025,45.3,1.63423798544359,9.262186457389568,2.599056269151937e-10,0.25510267449918494,1080.4014237873137,8.93956002950294,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,261.5,1.59,,,120.0,9.26,39.6,8.77,32.5,0.0056486,-0.12909600000000002,45.4,1.5863986603475053,9.262303154825078,1.3305805474285803e-10,0.2671285183081146,1074.00969531574,2.9334502589123788,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,261.2,1.59,,,120.0,9.26,39.6,8.77,32.5,0.0058338,-0.13503600000000002,45.4,1.6017789935784772,9.261957377380062,1.6918418804023026e-10,0.26342132607273083,1246.199084492346,0.27193363540170784,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,260.6,1.54,1.614,0.954,60.0,9.26,39.7,8.76,32.6,0.006019,-0.129025,45.3,1.63423798544359,9.262186457389568,2.599056269151937e-10,0.25510267449918494,1080.4014237873137,8.93956002950294,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM285PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,260.2,1.58,,,60.0,9.26,39.7,8.76,32.6,0.0070376,-0.129422,45.3,1.6542524684286437,9.261761894682428,3.4893888380258574e-10,0.2503213029080537,1315.615747082485,11.090021064100624,-0.429,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS285M-60,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.5,1.5397560000000001,1.614,0.954,60.0,9.54,38.7,8.9,32.0,0.00546642,-0.12732300000000002,45.0,1.5856292485674826,9.55165475341912,2.3460650288333557e-10,0.2166535600955447,177.3418107253095,6.60962654889132,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS285M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.5,1.5397560000000001,1.614,0.954,60.0,9.54,38.7,8.9,32.0,0.00546642,-0.12732300000000002,45.0,1.5856292485674826,9.55165475341912,2.3460650288333557e-10,0.2166535600955447,177.3418107253095,6.60962654889132,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS285M-60-MX,Jinko Solar Co Ltd,Mono-c-Si,0,285.0,261.8,1.58,,,60.0,12.0,35.0,9.38,30.4,0.0078,-0.1078,44.9,1.612532293518875,12.000813752726012,3.607018810550554e-09,0.0009999900029134098,14.746347436067648,40.2165151137268,-0.409,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS285PP-60-MX,Jinko Solar Co Ltd,Multi-c-Si,0,285.0,260.4,1.58,,,60.0,12.0,35.0,9.2,31.0,0.0078,-0.11375000000000002,45.3,1.9118325940966852,12.000807767023574,6.445610947370596e-08,0.0009999901310383018,14.855629471456496,-100.00000041371732,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM290M-60,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,266.7,1.5397560000000001,1.614,0.954,60.0,9.55,39.5,9.02,32.2,0.006207500000000001,-0.12166,44.9,1.5881468553589873,9.554155639407258,1.4988834972949318e-10,0.28415397500082806,653.0091861858914,9.735932194190656,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,264.7,1.5397560000000001,1.614,0.954,60.0,9.55,39.5,9.02,32.2,0.006589500000000002,-0.12166,46.2,1.6059670061001265,9.553674851210248,1.9764566402498183e-10,0.28000742846746857,727.6679803621796,12.166009776667314,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,264.7,1.5397560000000001,1.614,0.954,60.0,9.55,39.5,9.02,32.2,0.006589500000000002,-0.12166,46.2,1.6059670061001265,9.553674851210248,1.9764566402498183e-10,0.28000742846746857,727.6679803621796,12.166009776667314,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.7,1.59,,,120.0,9.55,39.5,9.02,32.2,0.005730000000000001,-0.13351000000000002,45.0,1.58211075914982,9.554321470042153,1.3629142270527785e-10,0.2855625985818845,631.0637774605534,-0.7837274691600169,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.5,1.59,,,120.0,9.55,39.5,9.02,32.2,0.0047750000000000015,-0.12798,45.3,1.5567869730622226,9.555033737431133,9.072333247840219e-11,0.2914951536188449,553.0242406581202,0.31817231987883315,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.1,1.59,,,120.0,9.55,39.5,9.02,32.2,0.0067805,-0.13548500000000002,45.3,1.604884120697549,9.553703694167229,1.9438551193758297e-10,0.28025889114626407,722.6495742225322,0.4650632108372647,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.3,1.59,,,120.0,9.55,39.5,9.02,32.2,0.005921000000000001,-0.13193000000000002,45.2,1.5872434597192315,9.554180362417393,1.4777696113943094e-10,0.2843646650690895,649.6286004755211,1.0459333149368255,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.7,1.5397560000000001,1.614,0.954,60.0,9.55,39.5,9.02,32.2,0.008279850000000002,-0.12245,44.9,1.6184818989727892,9.553345002296423,2.391488177335295e-10,0.2771060558454396,791.1395509129383,12.956072040367062,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.8,1.58,,,60.0,9.55,39.5,9.02,32.2,0.006303000000000001,-0.12324,45.1,1.576682337019188,9.55447189828966,1.2504244168517148e-10,0.2868311919818402,612.5448444096978,6.7316624532553675,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-72,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,261.3,1.9403519999999999,1.956,0.992,72.0,8.5,45.7,7.79,37.2,0.0037680500000000002,-0.13880004,46.6,1.8805638217931533,8.525414078088328,2.2782955128064536e-10,0.3702486314512864,123.83347051432997,16.578462395018413,-0.43507,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,261.4,1.9403519999999999,1.956,0.992,72.0,8.47,45.2,7.9,36.7,0.0027951000000000004,-0.14599600000000001,45.9,1.8514105397650218,8.482643445024019,2.072837147221836e-10,0.3803052961654301,254.77123524675872,8.845984224863988,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290P-60,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,265.3,1.54,1.614,0.954,60.0,9.32,39.9,8.82,32.8,0.006058000000000001,-0.129675,45.3,1.6431622305732112,9.321975047095874,2.643606137486202e-10,0.2500266409854144,1179.8448752444679,9.0314015623756,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290P-72,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,264.1,1.8818,1.94,0.97,72.0,8.69,44.9,8.11,35.8,0.0055181499999999994,-0.145925,45.1,1.8262080283865696,8.704046919620124,1.7949156686292074e-10,0.4619410430585084,285.77568487855643,6.328366757499564,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,262.2,1.9403519999999999,1.956,0.992,72.0,8.69,44.9,8.11,35.8,0.0049533,-0.152211,46.1,1.8331173903302758,8.703813028645884,1.9696165807321076e-10,0.46018894576160657,289.51235021393643,2.748014195388646,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-60,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,265.3,1.54,1.614,0.954,60.0,9.32,39.9,8.82,32.8,0.006058000000000001,-0.129675,45.3,1.6431622305732112,9.321975047095874,2.643606137486202e-10,0.2500266409854144,1179.8448752444679,9.0314015623756,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,266.3,1.59,,,120.0,9.32,39.8,8.86,32.8,0.0056852000000000005,-0.129748,45.4,1.595329326581145,9.320002771811053,1.363672991656872e-10,0.2491139956696065,837761.9493426175,3.0725377850179507,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,266.0,1.59,,,120.0,9.32,39.8,8.86,32.8,0.0058716,-0.135718,45.4,1.6114814708750902,9.32000272995114,1.7510891444773077e-10,0.24526672739579103,837504.0216028198,0.489142786734941,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-60-J4,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,265.3,1.54,1.614,0.954,60.0,9.32,39.9,8.82,32.8,0.006058000000000001,-0.129675,45.3,1.6431622305732112,9.321975047095874,2.643606137486202e-10,0.2500266409854144,1179.8448752444679,9.0314015623756,-0.426,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-60-V,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,264.9,1.58,,,60.0,9.32,39.9,8.82,32.8,0.0070832,-0.13007400000000002,45.3,1.6632899768925582,9.321559384936469,3.548961834551429e-10,0.24524738972190716,1465.774841304526,11.183375554303568,-0.429,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,290.0,262.0,1.9403519999999999,1.956,0.992,72.0,8.69,44.9,8.11,35.8,0.0040843,-0.14817000000000002,46.1,1.8197976499025297,8.704265294467602,1.6456831654288532e-10,0.4635689422276672,282.3926701107496,4.175166117414635,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM290PP-72B,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,262.2,1.9403519999999999,1.956,0.992,72.0,8.69,44.9,8.11,35.8,0.0049533,-0.152211,46.1,1.8331173903302758,8.703813028645884,1.9696165807321076e-10,0.46018894576160657,289.51235021393643,2.748014195388646,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290M-60,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.2,1.5397560000000001,1.614,0.954,60.0,9.55,39.5,9.02,32.2,0.00547215,-0.12995500000000001,45.0,1.5949824455050061,9.553969666002795,1.6678647022394578e-10,0.2825612831245097,679.7702030260165,3.6568507687406018,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290M-60B-MX,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,264.5,1.58,,,60.0,12.0,35.0,9.49,30.6,0.008280000000000001,-0.1078,46.2,1.2763720010358133,12.000865184157647,1.1686764457498895e-11,0.0009999900028610433,13.869740828646831,-11.895830507664076,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.2,1.5397560000000001,1.614,0.954,60.0,9.55,39.5,9.02,32.2,0.00547215,-0.12995500000000001,45.0,1.5949824455050061,9.553969666002795,1.6678647022394578e-10,0.2825612831245097,679.7702030260165,3.6568507687406018,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290M-60-MX,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,266.5,1.58,,,60.0,12.0,35.0,9.49,30.6,0.0078,-0.1078,44.9,1.5920782770017525,12.000739481425638,2.7906479853136653e-09,0.000999990000727526,16.22742632090055,37.24390977865694,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290M-72,Jinko Solar Co Ltd,Mono-c-Si,0,290.0,262.3,1.9403519999999999,1.956,0.992,72.0,8.47,45.2,7.9,36.7,0.0049973000000000005,-0.15458400000000003,45.6,1.8864783376358825,8.481686759414124,3.266620468091223e-10,0.37105726047887594,268.9244521793888,6.288183803730927,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290P-72,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,261.6,1.9403519999999999,1.956,0.992,72.0,9.15,42.7,8.54,34.0,0.003843000000000001,-0.142191,45.7,1.7486915585769958,9.164295764280844,2.237678235274765e-10,0.4203471976845662,269.0431421903396,5.43559409903667,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS290PP-60-MX,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,265.1,1.58,,,60.0,12.0,35.0,9.25,31.4,0.0078,-0.11375000000000002,45.3,1.865482472779925,12.000719227301909,4.2301886389756156e-08,0.0009999901219308503,16.68441393414819,-100.00000045518107,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS290PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,290.0,261.6,1.9403519999999999,1.956,0.992,72.0,9.15,42.7,8.54,34.0,0.003843000000000001,-0.142191,45.7,1.7486915585769958,9.164295764280844,2.237678235274765e-10,0.4203471976845662,269.0431421903396,5.43559409903667,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,271.5,1.5397560000000001,1.614,0.954,60.0,9.61,39.7,9.1,32.4,0.0062464999999999994,-0.12227600000000001,44.9,1.5951182723823096,9.612088468943579,1.487677017742982e-10,0.279203923933549,1284.745157988793,9.604613793401409,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,269.4,1.5397560000000001,1.614,0.954,60.0,9.61,39.7,9.1,32.4,0.0066309,-0.12227600000000001,46.2,1.6130124439835245,9.61164153383734,1.9619216124686528e-10,0.27507543212001784,1610.36958395608,12.03294220952623,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,269.4,1.5397560000000001,1.614,0.954,60.0,9.61,39.7,9.1,32.4,0.0066309,-0.12227600000000001,46.2,1.6130124439835245,9.61164153383734,1.9619216124686528e-10,0.27507543212001784,1610.36958395608,12.03294220952623,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,271.4,1.59,,,120.0,9.61,39.7,9.1,32.4,0.005765999999999999,-0.13418600000000003,45.0,1.5890350401338458,9.612243375721652,1.3521972524231335e-10,0.2806115227724557,1202.0623249178368,-0.9053833207043177,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,271.3,1.59,,,120.0,9.61,39.7,9.1,32.4,0.004805,-0.12862800000000002,45.3,1.5636175469189153,9.612907040852338,9.000970963390338e-11,0.2865155989928523,947.1539812863523,0.19482277214714205,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,270.9,1.59,,,120.0,9.61,39.7,9.1,32.4,0.006823099999999999,-0.13617100000000001,45.3,1.6118975843960686,9.611668999840555,1.9287337628963151e-10,0.27533212711452837,1585.346361072919,0.34275959169126474,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,271.0,1.59,,,120.0,9.61,39.7,9.1,32.4,0.0059581999999999994,-0.13259800000000002,45.2,1.5941911686928936,9.612111979654404,1.4662536419821871e-10,0.2794183116996633,1271.4184684530119,0.9226160637390866,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60-J4,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,271.4,1.5397560000000001,1.614,0.954,60.0,9.61,39.7,9.1,32.4,0.00833187,-0.12307,44.9,1.6255845151518769,9.611335278078894,2.374290561838882e-10,0.2721854993013241,1958.9211719020964,12.82372375582447,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,271.6,1.58,,,60.0,9.61,39.7,9.1,32.4,0.0063425999999999995,-0.123864,45.1,1.583604430402441,9.6123829420725,1.2409426909186744e-10,0.28186987772360744,1136.7335325988868,6.603045916324632,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-72,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,265.6,1.9403519999999999,1.956,0.992,72.0,8.59,46.0,7.85,37.6,0.00627929,-0.164404,46.7,1.9754181578073995,8.61347120626792,6.340884848215396e-10,0.32491246243778055,118.91158275537245,7.059254083732713,-0.4388,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,266.0,1.9403519999999999,1.956,0.992,72.0,8.55,45.3,8.02,36.8,0.0028215000000000002,-0.146319,45.9,1.850501881217547,8.558383152118564,1.9718887985623254e-10,0.3752966900479505,382.7661727358482,8.306072233491067,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295P-72,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,268.8,1.8818,1.94,0.97,72.0,8.76,45.1,8.15,36.2,0.0055626,-0.146575,45.1,1.8443425856962519,8.776483412285874,2.058100201209632e-10,0.4255217504666946,226.14072706102905,7.453908797189612,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,266.8,1.9403519999999999,1.956,0.992,72.0,8.76,45.1,8.15,36.2,0.0049932,-0.15288900000000002,46.1,1.8514274070941428,8.776247018331992,2.2604555232519236e-10,0.42372323269886913,228.46135668671772,3.842048446839211,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,271.0,1.59,,,120.0,9.37,40.1,8.95,33.1,0.0057157,-0.130726,45.4,1.6121427252925242,9.37000208812718,1.4764369957203126e-10,0.22281057587067093,999999.8033952118,3.6908004002514168,-0.403,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM295PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,270.7,1.59,,,120.0,9.37,40.1,8.95,33.1,0.0059031,-0.13674100000000003,45.4,1.628583212601038,9.370002034763038,1.8978679239571455e-10,0.21710675881738425,999999.8059563554,1.1006283792835119,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM295PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,266.8,1.9403519999999999,1.956,0.992,72.0,8.76,45.1,8.15,36.2,0.00518592,-0.1512654,45.5,1.878149719942666,8.775369552395574,3.1993311718903053e-10,0.4169637962652116,237.65189882396845,7.920498660291623,-0.4452,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,295.0,266.6,1.9403519999999999,1.956,0.992,72.0,8.76,45.1,8.15,36.2,0.0041172,-0.14883000000000002,46.1,1.8378529031472357,8.776701337289863,1.887484924070173e-10,0.4271715636050213,224.0553025332498,5.277423433794276,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM295PP-72B,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,266.0,1.9403519999999999,1.956,0.992,72.0,8.55,45.3,8.02,36.8,0.0028215000000000002,-0.146319,45.9,1.850501881217547,8.558383152118564,1.9718887985623254e-10,0.3752966900479505,382.7661727358482,8.306072233491067,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS295M-60B-MX,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,269.2,1.58,,,60.0,12.0,35.0,9.58,30.8,0.008280000000000001,-0.1078,46.2,1.8645324967013404,12.000696113992099,4.2209151376768536e-08,0.000999990009392934,17.238390474491016,-100.00000089474183,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS295M-60-MX,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,271.3,1.58,,,60.0,12.0,35.0,9.58,30.8,0.0078,-0.1078,44.9,1.5734453249984632,12.000669989042928,2.19528586482905e-09,0.0009999912422857572,17.910584262622006,34.52401002046448,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS295M-72,Jinko Solar Co Ltd,Mono-c-Si,0,295.0,266.9,1.9403519999999999,1.956,0.992,72.0,8.55,45.3,8.02,36.8,0.0050445,-0.154926,45.6,1.885463254106052,8.557525952741909,3.10785079028857e-10,0.36622218617428404,416.0536679401564,5.761262324197358,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS295P-72,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,266.2,1.9403519999999999,1.956,0.992,72.0,9.22,42.8,8.58,34.4,0.0038724000000000002,-0.142524,45.7,1.7649696472943297,9.236446825443654,2.656353265522935e-10,0.3740671594521243,209.7000153242234,6.85047689706938,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS295PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,295.0,266.2,1.9403519999999999,1.956,0.992,72.0,9.22,42.8,8.58,34.4,0.0038724000000000002,-0.142524,45.7,1.7649696472943297,9.236446825443654,2.656353265522935e-10,0.3740671594521243,209.7000153242234,6.85047689706938,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,275.2,1.58,,,60.0,9.72,40.1,9.21,32.6,0.006415200000000001,-0.123508,45.8,1.6022520195699053,9.721494769518237,1.3109755643422503e-10,0.29605376727649707,1925.1420197247137,8.375564895321743,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60BL,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,276.9,1.59,,,60.0,9.72,40.1,9.21,32.6,0.0056376,-0.119097,45.4,1.5522888119639144,9.722876694004922,5.848111414843842e-11,0.3075165494756258,1039.0612032364477,5.429498463300976,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,277.2,1.59,,,60.0,9.98,40.1,9.21,32.6,0.00530437,-0.11114918,45.4,1.5504018611074408,10.008633227149119,5.6354382387280645e-11,0.3039912555993818,105.95497152245353,12.626018348682614,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,276.1,1.59,,,120.0,9.72,40.1,9.21,32.6,0.005832,-0.13553800000000002,45.0,1.601040791151223,9.721527057482788,1.2863346203371551e-10,0.29632999855997055,1886.1953944445365,-1.3978264191937302,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,276.0,1.59,,,120.0,9.72,40.1,9.21,32.6,0.004860000000000001,-0.129924,45.3,1.5755164969058149,9.722221401454119,8.565605948431052e-11,0.3021700732025795,1322.1805033058965,-0.2997362200652882,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,274.2,1.63,,,20.0,9.98,39.4,9.29,32.3,0.004856268,-0.12462220000000002,45.4,1.6048504681481277,9.99557081995333,2.1215672781931115e-10,0.24651392659952986,158.00125443129843,9.737084370163142,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,275.6,1.59,,,120.0,9.72,40.1,9.21,32.6,0.0069012,-0.13754300000000003,45.3,1.624019179995951,9.720924768287686,1.8348375746151523e-10,0.2911032989360454,3059.7136566311515,-0.15652269301521768,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,275.8,1.59,,,120.0,9.72,40.1,9.21,32.6,0.0060264,-0.13393400000000003,45.2,1.6062395626277015,9.72138890988005,1.3951997831098098e-10,0.29514493649254625,2065.5121358231318,0.4230217384005685,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,277.4,1.59,,,60.0,9.98,40.1,9.21,32.6,0.0046113588,-0.11975063000000001,45.3,1.54424598251242,10.008931162919131,5.0823835815218394e-11,0.30542961553940956,105.36000937008548,3.70188423676988,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,276.3,1.58,,,60.0,9.72,40.1,9.21,32.6,0.006415200000000001,-0.125112,45.1,1.5956520912956436,9.721671419499538,1.18179026324719e-10,0.2975599358695193,1730.4355118327805,6.081884247928826,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-72,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,270.2,1.9403519999999999,1.956,0.992,72.0,8.67,46.4,7.9,38.0,0.0063377699999999995,-0.1658336,46.7,1.9983398304457995,8.6947167252474,6.81739654092767e-10,0.3130744131040523,109.81856822146523,7.62023572521321,-0.4388,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,270.7,1.9403519999999999,1.956,0.992,72.0,8.64,45.5,8.11,37.0,0.0028512000000000003,-0.146965,45.9,1.8590641624432263,8.647889637618892,2.0043749158214708e-10,0.3676474437852292,402.6134573737076,8.35481571852268,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300P-72,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,273.5,1.8818,1.94,0.97,72.0,8.84,45.3,8.2,36.6,0.0056134,-0.147225,45.1,1.8624623993313247,8.858235558035945,2.3562402357816933e-10,0.38900746026009475,188.5780615572774,8.568296426986574,-0.4249,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,271.5,1.9403519999999999,1.956,0.992,72.0,8.84,45.3,8.2,36.6,0.0050388,-0.153567,46.1,1.86972917151476,8.85799589842973,2.59038249757725e-10,0.38716331479946714,190.1835562247203,4.925943730367334,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,275.7,1.59,,,120.0,9.43,40.3,9.03,33.4,0.005752299999999999,-0.131378,45.4,1.6251697222545312,9.430001842511993,1.6037311779451367e-10,0.1953523023394671,999998.9763127015,4.331469684810868,-0.403,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM300PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,275.4,1.59,,,120.0,9.43,40.3,9.03,33.4,0.0059409,-0.137423,45.4,1.641830186237513,9.430001787596632,2.0625941670865713e-10,0.18952157162001032,999998.9687968725,1.7299153647812258,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM300PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,271.4,1.9403519999999999,1.956,0.992,72.0,8.84,45.3,8.2,36.6,0.005233280000000001,-0.15193619999999997,45.5,1.8967501196858776,8.857119134672397,3.6609739522111896e-10,0.3803304344279888,196.3955220849032,9.035601449654365,-0.4452,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,300.0,271.3,1.9403519999999999,1.956,0.992,72.0,8.84,45.3,8.2,36.6,0.0041548,-0.14948999999999998,46.1,1.8559060481718461,8.858453203767544,2.1618311289426127e-10,0.39067372633639114,187.15210664006622,6.370107733284525,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM300PP-72B,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,271.5,1.9403519999999999,1.956,0.992,72.0,8.84,45.3,8.2,36.6,0.0050388,-0.153567,46.1,1.86972917151476,8.85799589842973,2.59038249757725e-10,0.38716331479946714,190.1835562247203,4.925943730367334,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS300M-60-MX,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,276.0,1.58,,,60.0,12.0,35.0,9.69,31.0,0.0078,-0.1078,44.9,1.803012059467502,12.000633229329292,2.2880991425873176e-08,0.0009999902016887907,18.950299300087295,-99.99999964671731,-0.409,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKMS300M-72,Jinko Solar Co Ltd,Mono-c-Si,0,300.0,271.5,1.9403519999999999,1.956,0.992,72.0,8.64,45.5,8.11,37.0,0.0050976,-0.15561000000000003,45.6,1.8942034410813746,8.647045276532305,3.159396251132816e-10,0.35862226729991364,439.7977779306091,5.810317566236993,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS300P-72,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,270.8,1.9403519999999999,1.956,0.992,72.0,9.31,43.0,8.63,34.8,0.0039102,-0.14319,45.7,1.7840369415080255,9.32897392431659,3.0902695934463314e-10,0.3392837416541816,166.4775210852267,8.093105850847323,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS300PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,300.0,270.8,1.9403519999999999,1.956,0.992,72.0,9.31,43.0,8.63,34.8,0.0039102,-0.14319,45.7,1.7840369415080255,9.32897392431659,3.0902695934463314e-10,0.3392837416541816,166.4775210852267,8.093105850847323,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,279.9,1.58,,,60.0,9.83,40.3,9.3,32.8,0.0064878,-0.12412399999999998,45.8,1.6124873757712925,9.83292690891454,1.37014800031527e-10,0.28944087031446664,972.0849221309921,8.67016499103397,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60BL,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,281.7,1.59,,,60.0,9.83,40.3,9.3,32.8,0.0057014000000000006,-0.11969099999999999,45.4,1.56215447055411,9.834355001878292,6.113876443575344e-11,0.3008904756482924,679.162417378374,5.718854932922824,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,282.0,1.59,,,60.0,10.07,40.3,9.3,32.8,0.0053522050000000005,-0.11170353999999999,45.4,1.558504038124933,10.097811725439579,5.725615388288148e-11,0.2981132667940027,107.94010763699671,12.686323726391098,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,280.9,1.59,,,120.0,9.83,40.3,9.3,32.8,0.005898,-0.136214,45.0,1.6113202418032029,9.83295883804635,1.3455150262513e-10,0.2897047867779614,962.4719679471782,-1.1235610703255416,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,280.7,1.59,,,120.0,9.83,40.3,9.3,32.8,0.004915,-0.130572,45.3,1.585585880467576,9.833677104683044,8.958258593666656e-11,0.2955428945747905,790.0746036679488,-0.023747211217232195,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,279.0,1.63,,,20.0,10.07,39.6,9.38,32.52,0.004900062000000001,-0.12525480000000003,45.4,1.613997498542264,10.084855224638035,2.1748424684108362e-10,0.23861550523063738,161.75172823102875,9.875245541956932,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,280.3,1.59,,,120.0,9.83,40.3,9.3,32.8,0.006979299999999999,-0.138229,45.3,1.6344766633880954,9.832335757192478,1.919160812396394e-10,0.2844823688197289,1197.2403362662294,0.12107658766073878,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,281.6,1.63,,,20.0,10.07,39.6,9.38,32.52,0.0071722568,-0.12760704,45.1,1.588930816258705,10.085750029554893,1.4756468791956483e-10,0.24429722799974304,156.19482838571443,4.2430512548933725,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,280.5,1.59,,,120.0,9.83,40.3,9.3,32.8,0.0060945999999999995,-0.134602,45.2,1.6165503727785706,9.832816193511594,1.459173268300946e-10,0.2885227090400071,1007.0966076759784,0.7012284896347708,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60L,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,280.3,1.59,,,60.0,9.83,40.3,9.3,32.8,0.0060945999999999995,-0.126542,45.3,1.6137521385001232,9.832892372024325,1.3973095620575774e-10,0.28915496140227914,982.720702284091,6.793562473989935,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,282.2,1.59,,,60.0,10.07,40.3,9.3,32.8,0.0046529442,-0.12034789,45.3,1.552322850133841,10.098106117594465,5.164430854340203e-11,0.29954458060455325,107.32232759339043,3.758468066668701,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-60-V,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,281.0,1.58,,,60.0,9.83,40.3,9.3,32.8,0.0064878,-0.125736,45.1,1.6058500701461464,9.833109230087121,1.2354039108746568e-10,0.2909427112817031,919.8313835161707,6.372120174763763,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-72,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,275.6,1.9226999999999999,1.95,0.986,72.0,8.72,46.8,7.99,38.2,0.006522560000000002,-0.19164599999999998,46.5,2.014022026718051,8.74232725589536,6.785330767056086e-10,0.3318637717536976,129.61074954006187,-6.300831285145435,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,275.3,1.9403519999999999,1.956,0.992,72.0,8.72,45.7,8.2,37.2,0.0028776000000000006,-0.14761100000000002,45.9,1.866514926406508,8.726535058240612,2.0080118295699497e-10,0.3606792488459474,481.26938714798854,8.283480564999948,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305P-72,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,279.3,1.8354959999999998,1.924,0.954,72.0,8.91,45.6,8.3,36.8,0.00555093,-0.139536,45.1,1.8329454160657002,8.92608308822335,1.368540241631217e-10,0.40394809005189136,223.78647806550288,10.347802575982168,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,276.1,1.9403519999999999,1.956,0.992,72.0,8.91,45.6,8.3,36.8,0.0050787,-0.15458400000000003,46.1,1.8765881624483296,8.924697447244466,2.443851854071888e-10,0.39298407285253434,238.23786189565504,4.35265467979458,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305P-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,279.3,1.8354959999999998,1.924,0.954,72.0,8.91,45.6,8.3,36.8,0.00555093,-0.139536,45.1,1.8329454160657002,8.92608308822335,1.368540241631217e-10,0.40394809005189136,223.78647806550288,10.347802575982168,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305P-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,278.8,1.8354959999999998,1.924,0.954,72.0,8.91,45.6,8.3,36.8,0.00542619,-0.144096,45.3,1.839996491556877,8.9258552171715,1.5057377228245533e-10,0.4021698755910811,226.00345093409547,7.6705874196401425,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,280.4,1.59,,,120.0,9.49,40.6,9.11,33.6,0.0057889,-0.132356,45.4,1.6380853726880602,9.490001801461435,1.6340350792768002e-10,0.18976882131921727,999873.3417690315,4.435746156047038,-0.403,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM305PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,280.1,1.59,,,120.0,9.49,40.6,9.11,33.6,0.0059787,-0.138446,45.4,1.6548973141793044,9.490001745170478,2.1018989700963297e-10,0.18383037334426494,999869.7472767305,1.8329280292673291,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM305PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,279.3,1.8354959999999998,1.924,0.954,72.0,8.91,45.6,8.3,36.8,0.00555093,-0.139536,45.1,1.8329454160657002,8.92608308822335,1.368540241631217e-10,0.40394809005189136,223.78647806550288,10.347802575982168,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,305.0,275.9,1.9403519999999999,1.956,0.992,72.0,8.91,45.6,8.3,36.8,0.0041877,-0.15048,46.1,1.8627669511467166,8.925129892711885,2.039861838694525e-10,0.39644540399958583,233.46687821946512,5.790717269050563,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305PP-72B,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,276.1,1.9403519999999999,1.956,0.992,72.0,8.91,45.6,8.3,36.8,0.0050787,-0.15458400000000003,46.1,1.8765881624483296,8.924697447244466,2.443851854071888e-10,0.39298407285253434,238.23786189565504,4.35265467979458,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,279.3,1.8354959999999998,1.924,0.954,72.0,8.91,45.6,8.3,36.8,0.00555093,-0.139536,45.1,1.8329454160657002,8.92608308822335,1.368540241631217e-10,0.40394809005189136,223.78647806550288,10.347802575982168,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM305PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,278.8,1.8354959999999998,1.924,0.954,72.0,8.91,45.6,8.3,36.8,0.00542619,-0.144096,45.3,1.839996491556877,8.9258552171715,1.5057377228245533e-10,0.4021698755910811,226.00345093409547,7.6705874196401425,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS305M-72,Jinko Solar Co Ltd,Mono-c-Si,0,305.0,276.2,1.9403519999999999,1.956,0.992,72.0,8.72,45.7,8.2,37.2,0.005144800000000001,-0.15629400000000002,45.6,1.9017895259372093,8.7257256265074,3.1654718128365574e-10,0.35171532696402863,535.6546251948556,5.741932261699299,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS305P-72,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,275.5,1.9403519999999999,1.956,0.992,72.0,9.38,43.3,8.74,34.9,0.003939600000000001,-0.144189,45.7,1.7872822313785732,9.395169534279058,2.7685539621515957e-10,0.3587681206438189,221.84236193290613,7.055068834230474,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS305PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,305.0,275.5,1.9403519999999999,1.956,0.992,72.0,9.38,43.3,8.74,34.9,0.003939600000000001,-0.144189,45.7,1.7872822313785732,9.395169534279058,2.7685539621515957e-10,0.3587681206438189,221.84236193290613,7.055068834230474,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,284.6,1.58,,,60.0,9.92,40.5,9.4,33.0,0.0065472,-0.12474,45.8,1.6202053743500078,9.921614248157121,1.3790449902841234e-10,0.28367923279866614,1743.2877974495568,8.641436358116607,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60BL,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,286.4,1.59,,,60.0,9.92,40.5,9.4,33.0,0.0057536,-0.120285,45.4,1.5696373346895522,9.92298197514139,6.153273747574029e-11,0.2950659284887928,981.5824056643875,5.690206859956955,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,286.7,1.59,,,60.0,10.15,40.5,9.4,33.0,0.005394725,-0.1122579,45.4,1.5649840238488237,10.175096016444916,5.6707560724828616e-11,0.29272213651207285,118.39049122880535,12.516124472570077,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,285.6,1.59,,,120.0,9.92,40.5,9.4,33.0,0.005952,-0.13689,45.0,1.6190277472461272,9.921644908821733,1.3541447783276886e-10,0.28394282798490783,1712.3830215205655,-1.1502884157520294,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,285.5,1.59,,,120.0,9.92,40.5,9.4,33.0,0.00496,-0.13122,45.3,1.593172618840779,9.922332331344839,9.01538264834485e-11,0.28974899211460825,1232.3763197363517,-0.051328840285569735,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,284.6,1.62,,,20.0,9.92,40.5,9.4,33.0,0.00496,-0.128385,45.5,1.603129574536632,9.922064363144344,1.056083552653697e-10,0.28750871777759895,1381.5821029566594,3.4793931708684114,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,283.7,1.63,,,20.0,10.15,39.8,9.47,32.74,0.004938990000000001,-0.1258874,45.4,1.6222913460502262,10.163426016504777,2.2007261344288847e-10,0.23121403909888552,174.79664359037722,9.904308112368128,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,285.0,1.59,,,120.0,9.92,40.5,9.4,33.0,0.0070431999999999995,-0.138915,45.3,1.6404273986168405,9.920006955076348,1.8808173431697896e-10,0.2791227954126169,398159.28764848603,-0.12457741307155636,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,310.0,283.5,1.66,,,20.0,10.01,39.8,9.51,32.6,0.0047047,-0.129748,45.6,1.5975414807755277,10.010003364839916,1.5161125154446833e-10,0.2548492734518555,758280.8835511266,3.5302525246172767,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,286.3,1.63,,,20.0,10.15,39.8,9.47,32.74,0.007229236,-0.12825152,45.1,1.5971075201184162,10.164283447003776,1.4935308674039573e-10,0.23687324644890922,168.32516162178356,4.272995583277948,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,285.2,1.59,,,120.0,9.92,40.5,9.4,33.0,0.0061503999999999994,-0.13527000000000003,45.2,1.624283103723951,9.921508515641035,1.4685583697480795e-10,0.2827670648783241,1859.4768799304745,0.6741761724564331,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60L,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,285.0,1.59,,,60.0,9.92,40.5,9.4,33.0,0.0061503999999999994,-0.12717,45.3,1.621474137795169,9.921581277719536,1.4063432961702028e-10,0.2833953212462776,1777.8551594975163,6.76506016850135,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,286.9,1.59,,,60.0,10.15,40.5,9.4,33.0,0.004689909,-0.12094515000000002,45.3,1.5587572349525034,10.175378678259891,5.1128213049769084e-11,0.2941490015837876,117.6425472058809,3.5983718575898926,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-72,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,280.3,1.9226999999999999,1.95,0.986,72.0,8.78,47.1,8.05,38.5,0.00656744,-0.1928745,46.5,2.0280163993636013,8.801582468441625,6.921489499554453e-10,0.3236906976352324,131.68116575177277,-6.2028228056846135,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,280.0,1.9403519999999999,1.956,0.992,72.0,8.8,45.9,8.29,37.4,0.0029040000000000003,-0.148257,45.9,1.8739872107258155,8.80522101213836,2.012116281759822e-10,0.3538537078632152,596.419441067233,8.215015657556735,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310P-72,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,284.0,1.8354959999999998,1.924,0.954,72.0,8.96,45.9,8.38,37.0,0.0055820800000000005,-0.140454,45.1,1.8400677390478526,8.972691716834825,1.2936741456544403e-10,0.41034015609046426,289.68878566824145,9.782784527232568,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,280.8,1.9403519999999999,1.956,0.992,72.0,8.96,45.9,8.38,37.0,0.005107200000000001,-0.15560100000000002,46.1,1.8836995262847838,8.971382094948886,2.308377363311055e-10,0.39950261123866815,314.4890132822016,3.8125162072739975,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310P-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,284.0,1.8354959999999998,1.924,0.954,72.0,8.96,45.9,8.38,37.0,0.0055820800000000005,-0.140454,45.1,1.8400677390478526,8.972691716834825,1.2936741456544403e-10,0.41034015609046426,289.68878566824145,9.782784527232568,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310P-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,283.5,1.8354959999999998,1.924,0.954,72.0,8.96,45.9,8.38,37.0,0.005456640000000001,-0.145044,45.3,1.8470962523766046,8.972476831209653,1.42277534260473e-10,0.4085876517435885,293.4194886900819,7.115972317511807,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310PP-60H,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,285.2,1.59,,,120.0,9.59,40.8,9.19,33.9,0.0058499,-0.133008,45.4,1.6478525702636793,9.59000173739361,1.6939637768293484e-10,0.18113390499562432,999998.4262147818,4.651222684180717,-0.403,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM310PP-60H-V,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,284.9,1.59,,,120.0,9.59,40.8,9.19,33.9,0.0060417,-0.139128,45.4,1.6647887984818683,9.590001681307092,2.1791927268176575e-10,0.1752788498511506,999998.4134444472,2.0439079507259272,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM310PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,284.0,1.8354959999999998,1.924,0.954,72.0,8.96,45.9,8.38,37.0,0.0055820800000000005,-0.140454,45.1,1.8400677390478526,8.972691716834825,1.2936741456544403e-10,0.41034015609046426,289.68878566824145,9.782784527232568,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,310.0,280.6,1.9403519999999999,1.956,0.992,72.0,8.96,45.9,8.38,37.0,0.004211200000000001,-0.15147000000000002,46.1,1.8698776430265913,8.971790700705451,1.927118202616388e-10,0.4029250701986444,306.19121517674256,5.245017212395284,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310PP-72B,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,280.8,1.9403519999999999,1.956,0.992,72.0,8.96,45.9,8.38,37.0,0.005107200000000001,-0.15560100000000002,46.1,1.8836995262847838,8.971382094948886,2.308377363311055e-10,0.39950261123866815,314.4890132822016,3.8125162072739975,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,284.0,1.8354959999999998,1.924,0.954,72.0,8.96,45.9,8.38,37.0,0.0055820800000000005,-0.140454,45.1,1.8400677390478526,8.972691716834825,1.2936741456544403e-10,0.41034015609046426,289.68878566824145,9.782784527232568,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM310PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,283.5,1.8354959999999998,1.924,0.954,72.0,8.96,45.9,8.38,37.0,0.005456640000000001,-0.145044,45.3,1.8470962523766046,8.972476831209653,1.42277534260473e-10,0.4085876517435885,293.4194886900819,7.115972317511807,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS310M-72,Jinko Solar Co Ltd,Mono-c-Si,0,310.0,280.9,1.9403519999999999,1.956,0.992,72.0,8.8,45.9,8.29,37.4,0.0051920000000000004,-0.156978,45.6,1.9093977248940883,8.804446344480551,3.172273603960374e-10,0.3449495376742407,682.708396214705,5.676316100734821,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS310P-72,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,280.1,1.9403519999999999,1.956,0.992,72.0,9.43,43.6,8.82,35.2,0.0039606,-0.145188,45.7,1.7977625377264697,9.441593135094148,2.724634675664105e-10,0.3517252166018441,286.09769177983685,6.8581764794550235,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS310PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,310.0,280.1,1.9403519999999999,1.956,0.992,72.0,9.43,43.6,8.82,35.2,0.0039606,-0.145188,45.7,1.7977625377264697,9.441593135094148,2.724634675664105e-10,0.3517252166018441,286.09769177983685,6.8581764794550235,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,289.3,1.58,,,60.0,10.04,40.7,9.49,33.2,0.006626399999999999,-0.125356,45.8,1.6312528569722569,10.043861642508706,1.4579362725545224e-10,0.2769887481410912,720.1514627601804,9.034741209150427,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60BL,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,291.2,1.59,,,60.0,10.04,40.7,9.49,33.2,0.0058232,-0.120879,45.4,1.58027192387538,10.045310926180784,6.507927345558894e-11,0.2883753274164429,545.1569783006254,6.076682516384373,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,291.5,1.59,,,60.0,10.23,40.7,9.49,33.2,0.005437245,-0.11281226,45.4,1.5723233750809358,10.253427923780901,5.689632439283136e-11,0.2873893883068383,125.49099566196325,12.468700392167312,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,290.3,1.59,,,120.0,10.04,40.7,9.49,33.2,0.006023999999999999,-0.13756600000000002,45.0,1.6301377371601402,10.04389219598841,1.4332115796935729e-10,0.2772363253716799,715.1369502513545,-0.7840404327852174,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,290.2,1.59,,,120.0,10.04,40.7,9.49,33.2,0.00502,-0.131868,45.3,1.6040441162813943,10.044621734930603,9.540012519084983e-11,0.28304844398870443,614.8787644903974,0.31749470586944356,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,289.4,1.62,,,20.0,10.04,40.7,9.49,33.2,0.00502,-0.12901900000000002,45.5,1.614064678885395,10.044338255755187,1.1171306181085694e-10,0.2808121608551203,649.8820258442947,3.8581544670914147,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,288.4,1.63,,,20.0,10.23,40.0,9.56,32.95,0.0049779180000000004,-0.12652000000000002,45.4,1.6303131107682856,10.242114895442125,2.2176350467324796e-10,0.22517638332794068,190.14233693098782,9.89686298989007,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,289.8,1.59,,,120.0,10.04,40.7,9.49,33.2,0.007128399999999998,-0.13960100000000003,45.3,1.6536034227919172,10.043259951937985,2.0441649818778128e-10,0.2720402817627493,837.8298830385626,0.46506725206960065,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,289.6,1.62,,,20.0,10.04,40.7,9.49,33.2,0.0058232,-0.132275,45.4,1.6250596630732463,10.044031975886602,1.3254236438739883e-10,0.27836458291500354,693.1541511254867,2.590689606447604,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,315.0,288.2,1.66,,,20.0,10.09,39.9,9.63,32.7,0.0047423000000000005,-0.13007400000000002,45.6,1.6053710287708625,10.090002350040571,1.6214559622708302e-10,0.23285444396149538,999999.8110900162,4.024941036461497,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM315M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,291.1,1.63,,,20.0,10.23,40.0,9.56,32.95,0.0072862152,-0.128896,45.1,1.6050152516410288,10.242937900929299,1.5052032702907985e-10,0.23081150940033066,182.5026985597583,4.267459712500424,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,315.0,290.2,1.66,,,20.0,9.99,39.9,9.63,32.7,0.006793200000000001,-0.130473,45.2,1.6056705056153695,9.990173848038056,1.6122961588238043e-10,0.1922432078690243,11047.083101035128,3.487453159332253,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM315M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,290.0,1.59,,,120.0,10.04,40.7,9.49,33.2,0.006224799999999999,-0.13593800000000003,45.2,1.6354262566030637,10.043747745460594,1.5539943130410653e-10,0.2760627581314662,739.5567899714526,1.0456473722576722,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60L,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,289.7,1.59,,,60.0,10.04,40.7,9.49,33.2,0.006224799999999999,-0.12779800000000002,45.3,1.632547169279946,10.043826243102858,1.4871259278822027e-10,0.2767014691395902,726.0603047386894,7.153254936152117,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,291.7,1.59,,,60.0,10.23,40.7,9.49,33.2,0.0047268738,-0.12154241000000002,45.3,1.5660615274834986,10.25370299480093,5.129207335972717e-11,0.28881135340285713,124.6483911284805,3.5536630992476446,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,284.6,1.9403519999999999,1.956,0.992,72.0,8.87,46.1,8.38,37.6,0.0029270999999999998,-0.148903,45.9,1.8803820948697791,8.8730981316167,1.988434671460514e-10,0.34766194102877157,995.3617333646262,8.0320740482926,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315N-60H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,286.8,1.63,,,20.0,10.34,39.82,9.57,32.92,0.005163279000000001,-0.1231576852,46.07,1.652187676164564,10.357449844729675,3.4197233062440297e-10,0.20216711138156843,119.79522272435655,16.322583014118848,-0.43419,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315P-72,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,288.7,1.8354959999999998,1.924,0.954,72.0,9.01,46.2,8.48,37.2,0.00561323,-0.141372,45.1,1.8450682321558818,9.016973036833583,1.1920456749190246e-10,0.4165801927708653,538.2716387346924,8.98710207701635,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,285.4,1.9403519999999999,1.956,0.992,72.0,9.01,46.2,8.48,37.2,0.0051357,-0.156618,46.1,1.8885645342108701,9.015793007499646,2.1247515524099077e-10,0.40592748581171134,631.3486457302338,3.0522237501527694,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315P-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,288.7,1.8354959999999998,1.924,0.954,72.0,9.01,46.2,8.48,37.2,0.00561323,-0.141372,45.1,1.8450682321558818,9.016973036833583,1.1920456749190246e-10,0.4165801927708653,538.2716387346924,8.98710207701635,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315P-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,288.2,1.8354959999999998,1.924,0.954,72.0,9.01,46.2,8.48,37.2,0.00548709,-0.145992,45.3,1.852045848461145,9.016779948047741,1.310245278618418e-10,0.4148647412467641,551.3215972328767,6.335073775675209,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,288.7,1.8354959999999998,1.924,0.954,72.0,9.01,46.2,8.48,37.2,0.00561323,-0.141372,45.1,1.8450682321558818,9.016973036833583,1.1920456749190246e-10,0.4165801927708653,538.2716387346924,8.98710207701635,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,315.0,285.2,1.9403519999999999,1.956,0.992,72.0,9.01,46.2,8.48,37.2,0.0042347,-0.15246,46.1,1.8747814473121507,9.016160861887194,1.7742888789321003e-10,0.40929261955966917,598.5732553053015,4.476880307068023,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315PP-72B,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,285.4,1.9403519999999999,1.956,0.992,72.0,9.01,46.2,8.48,37.2,0.0051357,-0.156618,46.1,1.8885645342108701,9.015793007499646,2.1247515524099077e-10,0.40592748581171134,631.3486457302338,3.0522237501527694,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,288.7,1.8354959999999998,1.924,0.954,72.0,9.01,46.2,8.48,37.2,0.00561323,-0.141372,45.1,1.8450682321558818,9.016973036833583,1.1920456749190246e-10,0.4165801927708653,538.2716387346924,8.98710207701635,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM315PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,288.2,1.8354959999999998,1.924,0.954,72.0,9.01,46.2,8.48,37.2,0.00548709,-0.145992,45.3,1.852045848461145,9.016779948047741,1.310245278618418e-10,0.4148647412467641,551.3215972328767,6.335073775675209,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS315M-72,Jinko Solar Co Ltd,Mono-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.87,46.1,8.38,37.6,0.005233299999999999,-0.15766200000000002,45.6,1.9158866398498278,8.872379663548816,3.135237681969295e-10,0.3388287410474307,1262.9568687923538,5.498675030096838,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS315P-72,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,284.8,1.9403519999999999,1.956,0.992,72.0,9.48,43.9,8.93,35.3,0.003981600000000001,-0.146187,45.7,1.7993191771516452,9.485035232434457,2.388838027762911e-10,0.37134239916624523,699.1389183118823,5.659853090394538,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS315PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,315.0,284.8,1.9403519999999999,1.956,0.992,72.0,9.48,43.9,8.93,35.3,0.003981600000000001,-0.146187,45.7,1.7993191771516452,9.485035232434457,2.388838027762911e-10,0.37134239916624523,699.1389183118823,5.659853090394538,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60B,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,294.1,1.58,,,60.0,10.15,40.9,9.59,33.4,0.006699000000000001,-0.125972,45.8,1.6406079543932162,10.154280621942588,1.5033128761960311e-10,0.27081816376217066,642.1507944662524,9.210882890247555,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60BL,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,295.9,1.59,,,60.0,10.15,40.9,9.59,33.4,0.005887000000000001,-0.12147299999999998,45.4,1.5893047977248032,10.155740144612688,6.711673134422113e-11,0.28216777554145395,498.9426720388899,6.249598951694049,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,296.3,1.59,,,60.0,10.31,40.9,9.59,33.4,0.005479765000000001,-0.11336661999999999,45.4,1.578844745440906,10.330861267977298,5.639287184985639e-11,0.28220189619667163,139.46906749631455,12.306837886825752,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60H,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,295.1,1.59,,,120.0,10.15,40.9,9.59,33.4,0.00609,-0.138242,45.0,1.6395185430466652,10.154310486784285,1.4785630386294641e-10,0.2710577328470096,638.2658240438434,-0.6199677833007164,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HB,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,295.0,1.59,,,120.0,10.15,40.9,9.59,33.4,0.0050750000000000005,-0.132516,45.3,1.6132464248792144,10.155045469806803,9.840864584845881e-11,0.2768539405137872,556.948681064621,0.4824077258285463,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,294.1,1.62,,,20.0,10.15,40.9,9.59,33.4,0.0050750000000000005,-0.129653,45.5,1.623321972208292,10.154760237580696,1.1521656823595031e-10,0.27462677142443087,585.5720279924004,4.027462182349874,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,293.1,1.63,,,20.0,10.31,40.2,9.65,33.16,0.005016846000000001,-0.1271526,45.4,1.6383428385901448,10.320858663682825,2.2347762131273766e-10,0.21924955072264599,208.17138022852268,9.890424633813781,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,294.5,1.59,,,120.0,10.15,40.9,9.59,33.4,0.0072065,-0.140287,45.3,1.6631378872835951,10.153673840894614,2.1088014553681773e-10,0.2658774300793551,734.5599936849063,0.631283055513131,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,294.4,1.62,,,20.0,10.15,40.9,9.59,33.4,0.005887000000000001,-0.132925,45.4,1.634395169398111,10.154451589365648,1.3671169327525725e-10,0.27218522609704293,620.6054046845178,2.7588419882977315,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,320.0,292.9,1.66,,,20.0,10.17,40.1,9.73,32.9,0.0047799,-0.130726,45.6,1.6160663650270906,10.170002221342516,1.702251864577935e-10,0.2183714218910214,999998.829800514,4.3665878292349944,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM320M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,295.8,1.63,,,20.0,10.31,40.2,9.65,33.16,0.0073431944,-0.12954048,45.1,1.612929986695871,10.32164746258683,1.517017712176003e-10,0.22486124761258766,199.04073891338263,4.26277112399643,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,320.0,295.0,1.66,,,20.0,10.07,40.1,9.73,32.9,0.006847600000000001,-0.13112700000000002,45.2,1.6164075109204592,10.070159762780875,1.693787799666751e-10,0.17568422443071496,11073.566877661971,3.8336992040782456,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM320M-60H-V,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,294.7,1.59,,,120.0,10.15,40.9,9.59,33.4,0.006293,-0.136606,45.2,1.644836114772794,10.154165171876244,1.603025144462461e-10,0.2698889455574796,657.6855243621249,1.2120789663667508,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60L,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,294.5,1.59,,,60.0,10.15,40.9,9.59,33.4,0.006293,-0.12842599999999998,45.3,1.6419169930744193,10.154244800506303,1.5335563455056139e-10,0.2705303786409142,646.8817010702527,7.327050960017245,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,296.5,1.59,,,60.0,10.31,40.9,9.59,33.4,0.0047638386000000005,-0.12213966999999999,45.3,1.5725380101177666,10.331124628640804,5.0818210716501255e-11,0.28361945264450056,138.42215380989322,3.4014333084378783,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,289.3,1.9403519999999999,1.956,0.992,72.0,8.95,46.3,8.47,37.8,0.0029535,-0.149549,45.9,1.887903455646876,8.9518754381097,1.9936605370937223e-10,0.3411002046178408,1627.8053100413676,7.970371512988124,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,292.7,1.63,,,20.0,10.4,39.95,9.69,33.03,0.003942744000000001,-0.12320899600000002,44.85,1.64958186093163,10.413199034796287,3.084437299528999e-10,0.2028379124457419,159.8233847996929,15.750073985689266,-0.442985,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320N-60H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,291.5,1.63,,,20.0,10.4,39.95,9.69,33.03,0.005193240000000001,-0.123559757,46.07,1.6516462622205612,10.413131851391928,3.17943555359249e-10,0.20238579661764702,160.28299048710414,15.560008009083177,-0.43419,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,289.3,1.63,,,20.0,10.4,39.95,9.69,33.03,0.003930472,-0.12906646500000002,46.05,1.697160508305209,10.411697882744237,6.090833253607712e-10,0.1924727923495001,171.11791243754163,16.68697208760039,-0.46864,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320P-72,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,293.4,1.8354959999999998,1.924,0.954,72.0,9.05,46.4,8.56,37.4,0.005638150000000001,-0.141984,45.1,1.8495443171036625,9.052390161500798,1.1483446974843566e-10,0.4111761060450536,1556.8592003728897,8.601886461709604,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320P-72B,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,290.1,1.9403519999999999,1.956,0.992,72.0,9.05,46.4,8.56,37.4,0.005158500000000001,-0.157296,46.1,1.8930199233763463,9.05133401951788,2.0457725598091138e-10,0.40063040056510396,2717.8825311224764,2.6842409397676006,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320P-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,293.4,1.8354959999999998,1.924,0.954,72.0,9.05,46.4,8.56,37.4,0.005638150000000001,-0.141984,45.1,1.8495443171036625,9.052390161500798,1.1483446974843566e-10,0.4111761060450536,1556.8592003728897,8.601886461709604,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320P-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,292.9,1.8354959999999998,1.924,0.954,72.0,9.05,46.4,8.56,37.4,0.005511450000000001,-0.146624,45.3,1.8565048562006643,9.052217377986636,1.2618607176147496e-10,0.40948124654012,1671.256161489179,5.957101204995957,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,293.4,1.8354959999999998,1.924,0.954,72.0,9.05,46.4,8.56,37.4,0.005638150000000001,-0.141984,45.1,1.8495443171036625,9.052390161500798,1.1483446974843566e-10,0.4111761060450536,1556.8592003728897,8.601886461709604,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320PP-72(Plus),Jinko Solar Co Ltd,Multi-c-Si,0,320.0,289.9,1.9403519999999999,1.956,0.992,72.0,9.05,46.4,8.56,37.4,0.0042535,-0.15312,46.1,1.8792371268819874,9.051662913445162,1.708464142148681e-10,0.4039632729252937,2198.4721335635795,4.104324112741522,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320PP-72B,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,290.1,1.9403519999999999,1.956,0.992,72.0,9.05,46.4,8.56,37.4,0.005158500000000001,-0.157296,46.1,1.8930199233763463,9.05133401951788,2.0457725598091138e-10,0.40063040056510396,2717.8825311224764,2.6842409397676006,-0.432,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,293.4,1.8354959999999998,1.924,0.954,72.0,9.05,46.4,8.56,37.4,0.005638150000000001,-0.141984,45.1,1.8495443171036625,9.052390161500798,1.1483446974843566e-10,0.4111761060450536,1556.8592003728897,8.601886461709604,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM320PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,292.9,1.8354959999999998,1.924,0.954,72.0,9.05,46.4,8.56,37.4,0.005511450000000001,-0.146624,45.3,1.8565048562006643,9.052217377986636,1.2618607176147496e-10,0.40948124654012,1671.256161489179,5.957101204995957,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS320M-72,Jinko Solar Co Ltd,Mono-c-Si,0,320.0,290.2,1.9403519999999999,1.956,0.992,72.0,8.95,46.3,8.47,37.8,0.0052805,-0.15834600000000001,45.6,1.9235451387914655,8.951191270563244,3.143774417634731e-10,0.3323237414053326,2496.746272333195,5.439576881256287,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS320P-72,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,289.4,1.9403519999999999,1.956,0.992,72.0,9.53,44.1,9.01,35.5,0.0040026,-0.146853,45.7,1.805253914742447,9.531551307562786,2.338949851750078e-10,0.36600638075636605,2248.45413513178,5.422572564742847,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS320PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,292.8,1.8354959999999998,1.924,0.954,72.0,9.53,44.1,9.01,35.5,0.0064804,-0.14553000000000002,45.2,1.7863165856813175,9.532062795933216,1.8042252763839778e-10,0.37034910956082934,1710.9927720350447,3.876012578416148,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS320PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,320.0,292.8,1.8354959999999998,1.924,0.954,72.0,9.53,44.1,9.01,35.5,0.0064804,-0.14553000000000002,45.2,1.7863165856813175,9.532062795933216,1.8042252763839778e-10,0.37034910956082934,1710.9927720350447,3.876012578416148,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60BL,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,300.7,1.59,,,60.0,10.2,41.1,9.68,33.6,0.005916,-0.12206700000000001,45.4,1.5945252081293264,10.201836715739546,6.505787436943201e-11,0.2779107947116698,1543.3474769426266,5.92375841282672,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,301.0,1.59,,,60.0,10.5,41.1,9.68,33.6,0.00558075,-0.11392098,45.4,1.594700209739179,10.529038318822646,6.484694764146915e-11,0.2735804067997814,98.92426353601367,13.450488596383337,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,298.8,1.62,,,20.0,10.2,41.1,9.68,33.6,0.0051,-0.13028700000000001,45.5,1.6268770011648281,10.20000657141498,1.0888290887507277e-10,0.27076901159492806,419942.45975229907,3.4930894742481002,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,297.8,1.63,,,20.0,10.5,40.4,9.74,33.37,0.0051093,-0.1277852,45.4,1.655730271290325,10.517114239836216,2.581678007981745e-10,0.20974589474817332,128.6841838007997,11.048041437441908,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,299.1,1.62,,,20.0,10.2,41.1,9.68,33.6,0.005916,-0.13357500000000003,45.4,1.6396712344785005,10.200695256633319,1.3248258988236543e-10,0.26801000136308556,3931.9351446325163,2.4424558708463597,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,325.0,297.6,1.66,,,20.0,10.25,40.3,9.82,33.1,0.004817500000000001,-0.131378,45.6,1.6259840596429953,10.25000213344919,1.7649706950677426e-10,0.20809398126103784,999996.6932996036,4.605027325790214,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,300.6,1.63,,,20.0,10.5,40.4,9.74,33.37,0.007478519999999999,-0.13018496,45.1,1.630006538066906,10.518071909938497,1.7552226909324762e-10,0.2153906312420688,125.14458636296568,5.375712487188505,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,325.0,299.7,1.66,,,20.0,10.15,40.3,9.82,33.1,0.006902000000000001,-0.13178099999999998,45.2,1.6263312588720904,10.150150451588269,1.756427114270804e-10,0.16433497770734184,11086.645869689619,4.072298492614946,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325M-60L,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,299.2,1.59,,,60.0,10.2,41.1,9.68,33.6,0.006324,-0.129054,45.3,1.6472335663232653,10.200512086272285,1.486768304859185e-10,0.2663618938542164,5305.5407958225915,7.0002327259100205,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,301.2,1.59,,,60.0,10.5,41.1,9.68,33.6,0.004851629999999999,-0.12273693000000001,45.3,1.5884642457192937,10.529338942224623,5.85959635084286e-11,0.27497301887494,98.40902599054718,4.476285368084312,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-72,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,298.3,1.8354959999999998,1.924,0.954,72.0,9.03,46.5,8.55,38.0,0.007829009999999999,-0.14415,44.9,1.9055077187169216,9.031386991473365,2.2732936267801238e-10,0.33237152574173984,2163.904247060077,12.996626336424292,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,298.3,1.8354959999999998,1.924,0.954,72.0,9.03,46.5,8.55,38.0,0.007829009999999999,-0.14415,44.9,1.9055077187169216,9.031386991473365,2.2732936267801238e-10,0.33237152574173984,2163.904247060077,12.996626336424292,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,297.4,1.63,,,20.0,10.46,40.08,9.81,33.13,0.0039654906000000005,-0.1236099264,44.85,1.6489212237054227,10.468878570620616,2.8616901275287733e-10,0.20417048601339643,240.53685604970215,14.972897496550848,-0.442985,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325N-60H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,296.3,1.63,,,20.0,10.46,40.08,9.81,33.13,0.005223201,-0.12396182879999999,46.07,1.6510068391543833,10.468819827175055,2.951116205013965e-10,0.20372004076560435,241.60471256559288,14.787443684941604,-0.43419,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,294.0,1.63,,,20.0,10.46,40.08,9.81,33.13,0.003953147800000001,-0.129486456,46.05,1.6963312091063587,10.467589108895686,5.65335321728363e-10,0.19398483431938934,267.3675847322566,15.90636526742631,-0.46864,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM325P-72,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,298.1,1.8354959999999998,1.924,0.954,72.0,9.1,46.7,8.66,37.6,0.0056693,-0.142902,45.1,1.8612112204636566,9.100003638401747,1.153652453028739e-10,0.39974216793777806,999994.5863311997,8.584347161693238,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325P-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,298.1,1.8354959999999998,1.924,0.954,72.0,9.1,46.7,8.66,37.6,0.0056693,-0.142902,45.1,1.8612112204636566,9.100003638401747,1.153652453028739e-10,0.39974216793777806,999994.5863311997,8.584347161693238,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325P-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,297.6,1.8354959999999998,1.924,0.954,72.0,9.1,46.7,8.66,37.6,0.0055419,-0.147572,45.3,1.86852806346278,9.100003615164816,1.2727575452958185e-10,0.3971826794235123,999994.5482286913,5.974782035030615,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,298.1,1.8354959999999998,1.924,0.954,72.0,9.1,46.7,8.66,37.6,0.0056693,-0.142902,45.1,1.8612112204636566,9.100003638401747,1.153652453028739e-10,0.39974216793777806,999994.5863311997,8.584347161693238,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,298.1,1.8354959999999998,1.924,0.954,72.0,9.1,46.7,8.66,37.6,0.0056693,-0.142902,45.1,1.8612112204636566,9.100003638401747,1.153652453028739e-10,0.39974216793777806,999994.5863311997,8.584347161693238,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM325PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,297.6,1.8354959999999998,1.924,0.954,72.0,9.1,46.7,8.66,37.6,0.0055419,-0.147572,45.3,1.86852806346278,9.100003615164816,1.2727575452958185e-10,0.3971826794235123,999994.5482286913,5.974782035030615,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS325M-72,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,297.8,1.8354959999999998,1.924,0.954,72.0,9.03,46.5,8.55,38.0,0.0051741899999999995,-0.152985,45.0,1.8778349143219963,9.031923208574128,1.5853700491481888e-10,0.3391578576575662,1592.4411564218153,3.6927533843677494,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS325M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,325.0,297.8,1.8354959999999998,1.924,0.954,72.0,9.03,46.5,8.55,38.0,0.0051741899999999995,-0.152985,45.0,1.8778349143219963,9.031923208574128,1.5853700491481888e-10,0.3391578576575662,1592.4411564218153,3.6927533843677494,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS325PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,297.5,1.8354959999999998,1.924,0.954,72.0,9.55,44.5,9.12,35.7,0.0064940000000000015,-0.14685,45.2,1.8044616098188586,9.550003357237687,1.8613319319249318e-10,0.3514369648614742,999998.4657103296,4.113085644674716,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS325PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,325.0,297.5,1.8354959999999998,1.924,0.954,72.0,9.55,44.5,9.12,35.7,0.0064940000000000015,-0.14685,45.2,1.8044616098188586,9.550003357237687,1.8613319319249318e-10,0.3514369648614742,999998.4657103296,4.113085644674716,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330M-60BL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,305.8,1.59,,,60.0,10.61,41.3,9.77,33.8,0.005639215,-0.11447533999999998,45.4,1.604361062021844,10.639964718416472,6.745632985500264e-11,0.2676341447592703,94.7647252199405,13.721963209693307,-0.37746,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,303.7,1.63,,,20.0,10.61,40.6,9.84,33.54,0.0047647388,-0.12304642000000002,45.4,1.6245276503638533,10.628899314651031,1.441431330357255e-10,0.2166399447418989,121.6208053456341,10.572412588432474,-0.40616,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,302.6,1.63,,,20.0,10.61,40.6,9.84,33.54,0.005162826000000001,-0.12841780000000003,45.4,1.6642501070658096,10.627396247561425,2.6204253376608644e-10,0.20799665806998846,126.85750914268387,11.088970017209816,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,304.3,1.63,,,20.0,10.61,40.6,9.84,33.54,0.0050201215,-0.12495056,45.6,1.606643127550541,10.629599320663809,1.090788620392577e-10,0.22055780828848068,119.39793351017943,6.433834287154904,-0.39292,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-60HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,330.0,302.4,1.66,,,20.0,10.35,40.39,9.93,33.24,0.0048645,-0.13167140000000002,45.6,1.6322130726569748,10.350002001343045,1.85389714598285e-10,0.19330024886067335,999880.4039305301,4.937753805002981,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,305.3,1.63,,,20.0,10.61,40.6,9.84,33.54,0.0075568664,-0.13082944000000002,45.1,1.6383930057040423,10.628366603387928,1.7816734478183078e-10,0.21361385553713874,123.4002294850419,5.41514113786433,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-60HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,330.0,304.5,1.66,,,20.0,10.25,40.39,9.93,33.24,0.006970000000000001,-0.1320753,45.2,1.6325607224220107,10.250137348575898,1.845061108594524e-10,0.14860006682643492,11089.695003798217,4.4044345624372685,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330M-60L,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,304.0,1.59,,,60.0,10.31,41.3,9.77,33.8,0.006392200000000001,-0.129682,45.3,1.6541211507820477,10.310005925870364,1.478481516364804e-10,0.26099940633774965,454140.6013594145,6.857144068752,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-60L-Q,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,306.0,1.59,,,60.0,10.61,41.3,9.77,33.8,0.0049024566,-0.12333419,45.3,1.598119926721012,10.640269883404647,6.099339404325875e-11,0.2690165855930715,94.29392123872941,4.731462651241435,-0.37605,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,305.5,1.68,,,20.0,10.92,39.31,10.11,32.64,0.00577668,-0.10928180000000001,45.4,1.5289888765873363,10.94106507071974,7.206623086956192e-11,0.19516989072944044,101.17484328515768,13.714867156502178,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,305.5,1.68,,,20.0,10.65,39.8,9.94,33.2,0.007205683500000001,-0.11602496,45.4,1.5724167412801522,10.662913013210906,1.0573558619997408e-10,0.17978404642043055,148.27678857857993,11.812576894696512,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,305.7,1.68,,,20.0,10.92,39.31,10.11,32.64,0.00550368,-0.1104611,45.3,1.526475870058559,10.941173303833255,6.907438147647293e-11,0.1957135354957448,100.93804187326207,12.139593486753268,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-72,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,303.1,1.8354959999999998,1.924,0.954,72.0,9.11,46.7,8.64,38.2,0.00789837,-0.14477,44.9,1.913112477873594,9.110233710335784,2.2804270160246841e-10,0.32607380798303687,12710.360171794453,12.938812459570784,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,303.1,1.8354959999999998,1.924,0.954,72.0,9.11,46.7,8.64,38.2,0.00789837,-0.14477,44.9,1.913112477873594,9.110233710335784,2.2804270160246841e-10,0.32607380798303687,12710.360171794453,12.938812459570784,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,302.9,1.88,,,72.0,9.11,46.7,8.64,38.2,0.0058304,-0.142902,45.0,1.8729885512725788,9.110976856547644,1.3502345930608681e-10,0.3358271115947842,3131.8689886558896,9.947488291656244,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,302.1,1.63,,,20.0,10.52,40.21,9.93,33.24,0.0039882372000000004,-0.12401085680000001,44.85,1.6487171787386785,10.524469233487869,2.6722369223603053e-10,0.20422151473392752,480.7112193002487,14.260973188417484,-0.442985,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330N-60H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,301.0,1.63,,,20.0,10.52,40.21,9.93,33.24,0.0052531620000000005,-0.12436390060000001,46.07,1.6508202370172318,10.524419208883526,2.756752204833489e-10,0.20377339475253883,485.08602456041785,14.079468477520138,-0.43419,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,298.7,1.63,,,20.0,10.52,40.21,9.93,33.24,0.0039758236,-0.129906447,46.05,1.6959834875347346,10.523389522895789,5.281100449235464e-10,0.19420284358733186,602.7440205514401,15.1913854686951,-0.46864,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM330P-72,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.8,1.8354959999999998,1.924,0.954,72.0,9.14,46.9,8.74,37.8,0.005694220000000001,-0.143514,45.1,1.874181020701469,9.140003384334165,1.2389235515571556e-10,0.37020728888607257,999997.0934550109,9.172727394854407,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330P-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.8,1.8354959999999998,1.924,0.954,72.0,9.14,46.9,8.74,37.8,0.005694220000000001,-0.143514,45.1,1.874181020701469,9.140003384334165,1.2389235515571556e-10,0.37020728888607257,999997.0934550109,9.172727394854407,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330P-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.3,1.8354959999999998,1.924,0.954,72.0,9.14,46.9,8.74,37.8,0.005566260000000001,-0.148204,45.3,1.8816018333154991,9.140003360121401,1.3674334648697742e-10,0.3675505360406733,999990.7915650667,6.552571781844567,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.8,1.8354959999999998,1.924,0.954,72.0,9.14,46.9,8.74,37.8,0.005694220000000001,-0.143514,45.1,1.874181020701469,9.140003384334165,1.2389235515571556e-10,0.37020728888607257,999997.0934550109,9.172727394854407,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.4,1.9,,,144.0,9.14,46.9,8.74,37.8,0.004387200000000001,-0.15946,45.2,1.8575037308488052,9.140003438829233,9.896209330029431e-11,0.37617798887625686,999990.8956627449,-3.414619003508577,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.8,1.9,,,144.0,9.14,46.9,8.74,37.8,0.00457,-0.156177,45.3,1.8453554336429778,9.14000347851862,8.380718159529111e-11,0.38052724672787097,999990.94369631,-2.7085379018114706,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.8,1.8354959999999998,1.924,0.954,72.0,9.14,46.9,8.74,37.8,0.005694220000000001,-0.143514,45.1,1.874181020701469,9.140003384334165,1.2389235515571556e-10,0.37020728888607257,999997.0934550109,9.172727394854407,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM330PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.3,1.8354959999999998,1.924,0.954,72.0,9.14,46.9,8.74,37.8,0.005566260000000001,-0.148204,45.3,1.8816018333154991,9.140003360121401,1.3674334648697742e-10,0.3675505360406733,999990.7915650667,6.552571781844567,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS330M-72,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,302.5,1.8354959999999998,1.924,0.954,72.0,9.11,46.7,8.64,38.2,0.00522003,-0.153643,45.0,1.8853179421545825,9.110743794208048,1.5899287982788242e-10,0.332821523816448,4076.404844832802,3.6373160820240145,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS330M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,330.0,302.5,1.8354959999999998,1.924,0.954,72.0,9.11,46.7,8.64,38.2,0.00522003,-0.153643,45.0,1.8853179421545825,9.110743794208048,1.5899287982788242e-10,0.332821523816448,4076.404844832802,3.6373160820240145,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS330PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.2,1.8354959999999998,1.924,0.954,72.0,9.57,44.7,9.2,35.9,0.0065076000000000005,-0.14751000000000003,45.2,1.8198527033410892,9.570261882227957,2.0578743642389216e-10,0.3114559190510062,11381.615393845432,4.944595006059476,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS330PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,330.0,302.2,1.8354959999999998,1.924,0.954,72.0,9.57,44.7,9.2,35.9,0.0065076000000000005,-0.14751000000000003,45.2,1.8198527033410892,9.570261882227957,2.0578743642389216e-10,0.3114559190510062,11381.615393845432,4.944595006059476,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,308.5,1.63,,,20.0,10.73,40.8,9.93,33.74,0.0048186284,-0.12365256,45.4,1.6353442269203882,10.75032668647468,1.5177479981473446e-10,0.2109068069537806,111.33295591247158,10.941167264970964,-0.40616,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.3,1.63,,,20.0,10.73,40.8,9.93,33.74,0.0052212180000000006,-0.1290504,45.4,1.675391388056974,10.748755583085444,2.7587251031997054e-10,0.20226103962103345,115.71280028530869,11.458147294527581,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,309.1,1.63,,,20.0,10.73,40.8,9.93,33.74,0.005076899500000001,-0.12556608,45.6,1.617332703594075,10.751057052210001,1.1489532992235721e-10,0.21482162749967076,109.46622724488824,6.792013262593592,-0.39292,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-60HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,335.0,307.1,1.66,,,20.0,10.44,40.46,10.03,33.4,0.004906799999999999,-0.1318996,45.6,1.6388870196815757,10.440166330381917,1.9811356910202284e-10,0.17376074964116633,10906.405328522493,5.427682621881548,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,310.1,1.63,,,20.0,10.73,40.8,9.93,33.74,0.0076423352,-0.13147392,45.1,1.6493493821496015,10.749769003972512,1.8766538079108496e-10,0.2078741245076611,112.82760728164088,5.770393655853261,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-60HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,335.0,309.2,1.66,,,20.0,10.34,40.46,10.03,33.4,0.0070312000000000005,-0.1323042,45.2,1.6387105613243111,10.340102004368555,1.9570506446574478e-10,0.12958138454881019,13135.416208974922,4.828574295848634,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,310.3,1.68,,,20.0,11.04,39.41,10.23,32.75,0.0058401600000000005,-0.1095598,45.4,1.5296263750425179,11.060517150038198,6.904152965137765e-11,0.1912743751368041,102.92214653266315,13.219376699797161,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,310.3,1.68,,,20.0,10.77,39.9,10.06,33.3,0.0072868743,-0.11631648,45.4,1.576139949782639,10.782449855658047,1.0663219411965138e-10,0.1764281719541936,152.62276934406069,11.784698540761271,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,310.4,1.68,,,20.0,11.04,39.41,10.23,32.75,0.00556416,-0.1107421,45.3,1.530344558988927,11.060486616142764,6.988290594341479e-11,0.1911207077633919,102.9927353707269,12.142767236719253,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-72,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,307.9,1.8354959999999998,1.924,0.954,72.0,9.18,46.9,8.72,38.4,0.005967,-0.144452,44.9,1.8852834527483633,9.180003599576185,1.4419215575962165e-10,0.32880468521393846,838683.6349910012,9.72371594769365,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,305.5,1.8354959999999998,1.924,0.954,72.0,9.18,46.9,8.72,38.4,0.0063342,-0.144452,46.2,1.906608256695133,9.187325639122184,1.9060157022097578e-10,0.3234984160554095,999999.9422920248,12.171505595199138,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335M-72B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,305.5,1.8354959999999998,1.924,0.954,72.0,9.18,46.9,8.72,38.4,0.0063342,-0.144452,46.2,1.906608256695133,9.187325639122184,1.9060157022097578e-10,0.3234984160554095,999999.9422920248,12.171505595199138,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.9,1.9,,,144.0,9.18,46.9,8.72,38.4,0.004773599999999999,-0.157584,45.0,1.8584643714281845,9.180270066929564,1.0065921514209958e-10,0.3352929015276341,11397.14754634755,-2.206591003048068,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.5,1.9,,,144.0,9.18,46.9,8.72,38.4,0.0051408,-0.155239,45.3,1.864355030221211,9.180160551740984,1.0903242949753036e-10,0.33386207817522784,19089.562962427925,-0.12831393099275512,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,306.9,1.9,,,144.0,9.18,46.9,8.72,38.4,0.0054161999999999995,-0.15477,45.3,1.8852121209433834,9.18000360407783,1.440564933356378e-10,0.32882185725027446,837679.5734262023,2.4147180300029603,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.4,1.9,,,144.0,9.18,46.9,8.72,38.4,0.0053244,-0.158053,44.9,1.8897002499463769,9.180003593132408,1.5282471250258742e-10,0.32774192600712676,837478.6977594806,0.7633235173690093,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.8,1.8354959999999998,1.924,0.954,72.0,9.18,46.9,8.72,38.4,0.007959059999999999,-0.14539,44.9,1.9217664744960314,9.190612589122852,2.3149736208171864e-10,0.31978655267303746,999999.8224080739,12.995920983883355,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.6,1.88,,,72.0,9.18,46.9,8.72,38.4,0.0058752,-0.143514,45.0,1.880827646366136,9.180003611151724,1.3593975341272973e-10,0.32987783368709067,838717.1655904966,9.934573096246053,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,306.8,1.63,,,20.0,10.58,40.34,10.04,33.37,0.0040109838,-0.12441178720000001,44.85,1.650071500077359,10.580773889506998,2.54996817183301e-10,0.20176139343891294,2758.322833246146,13.756525763123328,-0.442985,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,303.4,1.63,,,20.0,10.58,40.34,10.04,33.37,0.0039984994,-0.13032643800000002,46.05,1.6976136396877695,10.58000303510196,5.063421280059462e-10,0.19180718500126925,668873.9465206924,14.727044671268391,-0.46864,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM335P-72,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,306.2,1.835,1.924,0.954,72.0,9.18,47.2,8.82,38.0,0.005967,-0.1534,45.3,1.9338496267403436,9.180258702558094,2.3052599013866492e-10,0.33109718303779806,11748.946129245049,7.953818332047088,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,306.2,1.835,1.924,0.954,72.0,9.18,47.2,8.82,38.0,0.005967,-0.1534,45.3,1.9338496267403436,9.180258702558094,2.3052599013866492e-10,0.33109718303779806,11748.946129245049,7.953818332047088,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,307.1,1.9,,,144.0,9.18,47.2,8.82,38.0,0.0044063999999999996,-0.16048,45.2,1.8732014562389623,9.180274388849883,1.0459962228563382e-10,0.3534378017678811,11824.695921241311,-3.015729604500863,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,307.5,1.9,,,144.0,9.18,47.2,8.82,38.0,0.0045899999999999995,-0.157176,45.3,1.8609347336432087,9.180277555532415,8.859243309213567e-11,0.35795619278913454,11839.22670188089,-2.3055115440209875,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,306.2,1.835,1.924,0.954,72.0,9.18,47.2,8.82,38.0,0.005967,-0.1534,45.3,1.9338496267403436,9.180258702558094,2.3052599013866492e-10,0.33109718303779806,11748.946129245049,7.953818332047088,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM335PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,335.0,305.0,1.88,,,72.0,9.18,47.2,8.82,38.0,0.006701399999999999,-0.159536,45.3,1.9805136641362224,9.180246908565046,4.0970338381396985e-10,0.31390390050566,11670.93354376943,8.614230966504005,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS335M-72,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.2,1.8354959999999998,1.924,0.954,72.0,9.18,46.9,8.72,38.4,0.005260139999999999,-0.154301,45.0,1.893748107748418,9.180003580600097,1.611509171766719e-10,0.32676880665146596,837920.8813527946,3.6824180146274244,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKMS335M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,335.0,307.2,1.8354959999999998,1.924,0.954,72.0,9.18,46.9,8.72,38.4,0.005260139999999999,-0.154301,45.0,1.893748107748418,9.180003580600097,1.611509171766719e-10,0.32676880665146596,837920.8813527946,3.6824180146274244,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,313.2,1.63,,,20.0,10.82,41.0,10.02,33.93,0.0048590456,-0.12425870000000001,45.4,1.6434343980739599,10.839771731212386,1.533302219745763e-10,0.20739844676717606,113.49796437113987,10.955273074692428,-0.40616,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.1,1.63,,,20.0,10.82,41.0,10.02,33.93,0.005265012,-0.12968300000000002,45.4,1.6836816319895225,10.838217485398667,2.787003188467506e-10,0.1987842076780605,118.06487915300407,11.472441770322973,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,313.8,1.63,,,20.0,10.82,41.0,10.02,33.93,0.005119483,-0.1261816,45.6,1.6253347410442822,10.840494545069857,1.1607597143466261e-10,0.21129858941783133,111.55411206339562,6.805845255389261,-0.39292,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,314.9,1.63,,,20.0,10.82,41.0,10.02,33.93,0.0077064368,-0.13211840000000002,45.1,1.6575155397087027,10.839219673672236,1.896058538834557e-10,0.2043755344802292,115.05623777720672,5.784953706085306,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-60HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,340.0,314.0,1.66,,,20.0,10.43,40.6,10.11,33.62,0.0070924000000000004,-0.13276200000000002,45.2,1.6462568753128701,10.43011448190119,2.0303106661158307e-10,0.12157582972743224,11076.322790490434,5.066950298173461,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340M-66HB,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,314.8,1.77,,,22.0,10.01,43.6,9.3,36.56,0.0037015978999999995,-0.12989747999999998,45.3,1.6778769158823312,10.02484193960597,5.028473497661242e-11,0.19767480050493197,133.31982346532604,3.9441987009307726,-0.37224,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,315.1,1.68,,,20.0,11.16,39.51,10.35,32.85,0.005903640000000001,-0.10983780000000001,45.4,1.5364999385669378,11.179816222430517,7.346076264407406e-11,0.1872174052534633,105.43615325090579,13.68465839434626,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,315.0,1.68,,,20.0,10.89,40.0,10.18,33.4,0.0073680651000000005,-0.116608,45.4,1.5798748741213768,10.901995042892679,1.0754278932778692e-10,0.17314701844714747,157.19585876540955,11.758547381014573,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-72,Jinko Solar Co Ltd,Multi-c-Si,0,340.0,312.6,1.8354959999999998,1.924,0.954,72.0,9.24,47.1,8.79,38.7,0.006006000000000001,-0.145068,44.9,1.896278369445735,9.253328144549792,1.5108972672788094e-10,0.3096482430039659,999999.9856451392,10.069060567638502,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,310.2,1.8354959999999998,1.924,0.954,72.0,9.24,47.1,8.79,38.7,0.006375600000000001,-0.145068,46.2,1.9180037174580407,9.258028898075018,2.0028167626476613e-10,0.3043393676251314,999999.9856368328,12.552916519620595,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340M-72B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,310.2,1.8354959999999998,1.924,0.954,72.0,9.24,47.1,8.79,38.7,0.006375600000000001,-0.145068,46.2,1.9180037174580407,9.258028898075018,2.0028167626476613e-10,0.3043393676251314,999999.9856368328,12.552916519620595,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.6,1.9,,,144.0,9.24,47.1,8.79,38.7,0.0048048000000000006,-0.158256,45.0,1.870061148562558,9.240003566272065,1.0650745467917234e-10,0.3162684606452899,819525.1873378559,-1.8133882945275794,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.2,1.9,,,144.0,9.24,47.1,8.79,38.7,0.005174400000000001,-0.155901,45.3,1.8762325062322582,9.240003548365255,1.1570670887142999e-10,0.3147842432592665,819802.4611465733,0.29783733027866577,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,311.6,1.9,,,144.0,9.24,47.1,8.79,38.7,0.0054516,-0.15543,45.3,1.8976096670831024,9.240003488882051,1.535240609428933e-10,0.3096578840262357,820228.8471249436,2.887899443013283,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.1,1.9,,,144.0,9.24,47.1,8.79,38.7,0.005359200000000001,-0.158727,44.9,1.9021545446840908,9.240003477599279,1.629041805339088e-10,0.30857095412719365,820008.2407771221,1.2305547105469818,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM340M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.5,1.8354959999999998,1.924,0.954,72.0,9.24,47.1,8.79,38.7,0.00801108,-0.14601,44.9,1.9332416107390997,9.261320121132874,2.4314009679943734e-10,0.30062825042012103,999999.9834889773,13.377420218670354,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.3,1.88,,,72.0,9.24,47.1,8.79,38.7,0.005913600000000001,-0.144126,45.0,1.8918829907631731,9.252375914389777,1.426030622035512e-10,0.3107248739918921,999999.9856466246,10.291372300220884,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,311.6,1.63,,,20.0,10.64,40.47,10.16,33.47,0.0040337304,-0.12481271760000001,44.85,1.6581818463432707,10.640001950427981,2.67571921093982e-10,0.18325448430341645,999999.8679898013,14.14099446458132,-0.442985,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,308.1,1.63,,,20.0,10.64,40.47,10.16,33.47,0.0040211752,-0.130746429,46.05,1.7078934505806744,10.640001789518807,5.444523162359824e-10,0.16809315184155582,999999.8651283109,15.347274614602236,-0.46864,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,340.0,311.9,1.9,,,144.0,9.22,47.5,8.9,38.2,0.0044256,-0.16150000000000003,45.2,1.8883171845302535,9.220255327204558,1.0965278826120603e-10,0.32983393933922855,11910.497759051463,-2.6807149605425122,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,340.0,312.2,1.9,,,144.0,9.22,47.5,8.9,38.2,0.00461,-0.158175,45.3,1.875945559204334,9.22025864838035,9.289110315174287e-11,0.33452152735399115,11924.65635558286,-1.9662503848610577,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,340.0,309.7,1.88,,,72.0,9.22,47.5,8.9,38.2,0.0067306,-0.16055000000000003,45.3,1.9959751308211982,9.220002686075444,4.260256657143581e-10,0.291200020976677,999999.3260017162,8.919043757423504,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS340M-72,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.0,1.8354959999999998,1.924,0.954,72.0,9.24,47.1,8.79,38.7,0.0052945200000000005,-0.154959,45.0,1.9046688431967802,9.255144768542477,1.6859298486105922e-10,0.3075954297147166,999999.9856547838,3.993376685034627,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS340M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,340.0,312.0,1.8354959999999998,1.924,0.954,72.0,9.24,47.1,8.79,38.7,0.0052945200000000005,-0.154959,45.0,1.9046688431967802,9.255144768542477,1.6859298486105922e-10,0.3075954297147166,999999.9856547838,3.993376685034627,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340P-72,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,315.6,1.835,1.924,0.954,72.0,9.22,47.5,8.9,38.2,0.005993,-0.154375,45.3,1.9495345323044893,9.220239628044837,2.4157865666383406e-10,0.30663055637738584,11798.0471594908,8.325095706257919,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,315.6,1.835,1.924,0.954,72.0,9.22,47.5,8.9,38.2,0.005993,-0.154375,45.3,1.9495345323044893,9.220239628044837,2.4157865666383406e-10,0.30663055637738584,11798.0471594908,8.325095706257919,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM340PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,315.6,1.835,1.924,0.954,72.0,9.22,47.5,8.9,38.2,0.005993,-0.154375,45.3,1.9495345323044893,9.220239628044837,2.4157865666383406e-10,0.30663055637738584,11798.0471594908,8.325095706257919,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-60HBL,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,318.0,1.63,,,20.0,10.91,41.2,10.11,34.12,0.0048994628000000005,-0.12486484000000002,45.4,1.6515282317515814,10.9292282105497,1.5489573271100004e-10,0.2039514740876542,115.72114975646537,10.969695893776032,-0.40616,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-60HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.8,1.63,,,20.0,10.91,41.2,10.11,34.12,0.005308806,-0.13031560000000003,45.4,1.6919756994884037,10.927690811893294,2.8154638363934585e-10,0.1953681660366245,120.48439551050807,11.487052862502619,-0.42373,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,318.6,1.63,,,20.0,10.91,41.2,10.11,34.12,0.0051620665000000005,-0.12679712,45.6,1.6333403771357966,10.929943479406795,1.1726431371217009e-10,0.2078372142661979,113.69651210134307,6.8199823249935285,-0.39292,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,319.6,1.63,,,20.0,10.91,41.2,10.11,34.12,0.0077705384,-0.13276288000000003,45.1,1.6656853824573963,10.928681782847208,1.9155886637108347e-10,0.20093815166130669,117.34615019856712,5.799799781615739,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,319.1,1.77,,,22.0,10.27,43.32,9.41,36.67,0.0032757192,-0.136163424,45.2,1.6998478202484781,10.287224697883886,8.366666811971483e-11,0.14355810253035917,85.59463468168407,2.527374407919888,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-66HB,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,319.6,1.77,,,22.0,10.13,43.63,9.42,36.63,0.0037459727000000004,-0.12998685899999998,45.3,1.6793398744331272,10.144157622009299,5.117981681249861e-11,0.19012332776743335,136.0362159673313,3.988957863229472,-0.37224,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,317.0,1.82,,,22.0,10.2,43.64,9.37,36.82,0.0066569279999999995,-0.1381206,45.7,1.800463768990951,10.214447976604948,2.9067379964000134e-10,0.13927657471980068,98.32664706683461,12.154623035322258,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,319.1,1.77,,,22.0,10.27,43.32,9.41,36.67,0.0033614737000000005,-0.1260612,45.5,3.1381814910100063,10.270521567749027,2.302001901047045e-09,3.7441994740829547,987803.0481881312,-37.90426332674262,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,319.8,1.68,,,20.0,11.28,39.61,10.47,32.95,0.00596712,-0.11011580000000001,45.4,1.5401475249441854,11.299261955669163,7.402146752676887e-11,0.18392578931103074,107.70884129060191,13.653032114444589,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,319.8,1.68,,,20.0,11.01,40.1,10.3,33.5,0.0074492559,-0.11689952,45.4,1.583621078468774,11.021548475468077,1.0846707094950544e-10,0.16993813947750414,162.01436798980254,11.734051674621856,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,320.0,1.68,,,20.0,11.28,39.61,10.47,32.95,0.00568512,-0.11130410000000002,45.3,1.537614423565231,11.299366835367222,7.094534080448494e-11,0.1844553460029896,107.43398626227344,12.078176357633142,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM345M-72,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,317.3,1.8354959999999998,1.924,0.954,72.0,9.31,47.3,8.87,38.9,0.0060515000000000005,-0.14568399999999998,44.9,1.9078749332700613,9.310002705203459,1.5919405717580357e-10,0.29051565365734755,999999.8972693511,10.479029828136468,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,314.9,1.8354959999999998,1.924,0.954,72.0,9.31,47.3,8.87,38.9,0.006423900000000001,-0.14568399999999998,46.2,1.9302540739335419,9.310002633627585,2.1220637712753518e-10,0.28281502680948023,999999.9688064771,13.027803260596565,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,314.9,1.8354959999999998,1.924,0.954,72.0,9.31,47.3,8.87,38.9,0.006423900000000001,-0.14568399999999998,46.2,1.9302540739335419,9.310002633627585,2.1220637712753518e-10,0.28281502680948023,999999.9688064771,13.027803260596565,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,317.3,1.9,,,144.0,9.31,47.3,8.87,38.9,0.0048411999999999995,-0.158928,45.0,1.8801695711520146,9.310002793848268,1.104761966411814e-10,0.3000490249210765,999999.6906021603,-1.5834047501127677,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.9,1.9,,,144.0,9.31,47.3,8.87,38.9,0.0052136000000000005,-0.156563,45.3,1.8863909721127818,9.310002773937873,1.2003339403134702e-10,0.29790825068253846,999999.7861497249,0.533964358986865,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.4,1.9,,,144.0,9.31,47.3,8.87,38.9,0.0054929,-0.15609,45.3,1.9079265732826378,9.310002705038283,1.593009155295414e-10,0.290497884410906,999999.8973526978,3.1321492134413136,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.8,1.9,,,144.0,9.31,47.3,8.87,38.9,0.005399800000000001,-0.15940100000000001,44.9,1.9125151550512038,9.310002690361323,1.6906364675864956e-10,0.28891896069492895,999999.8972096393,1.472252600904825,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,317.2,1.8354959999999998,1.924,0.954,72.0,9.31,47.3,8.87,38.9,0.00807177,-0.14662999999999998,44.9,1.9460188029975671,9.31000258322329,2.5880399213371856e-10,0.2773904085359015,999999.968597967,13.902559403172033,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,317.0,1.88,,,72.0,9.31,47.3,8.87,38.9,0.0059584,-0.14473799999999998,45.0,1.9033399494840009,9.310002719709848,1.5006273641551045e-10,0.29207613439319535,999999.897426018,10.689990324839837,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.3,1.63,,,20.0,10.7,40.6,10.27,33.6,0.004056477,-0.125213648,44.85,1.66796896146278,10.700001707811095,2.872292570337929e-10,0.15955862911353988,999987.3499363165,14.741751634380797,-0.442985,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,312.8,1.63,,,20.0,10.7,40.6,10.27,33.6,0.004043851,-0.13116642,46.05,1.718069678272226,10.700001540363752,5.841099587737735e-10,0.14387818718216439,999986.8653714625,15.950223306120854,-0.46864,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345P-72,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,315.6,1.835,1.924,0.954,72.0,9.29,47.8,8.98,38.4,0.0060385,-0.15535,45.3,1.9621785370920763,9.290237310701078,2.4441585875849587e-10,0.30161653276346145,11807.418159789508,8.36110426844041,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,315.6,1.835,1.924,0.954,72.0,9.29,47.8,8.98,38.4,0.0060385,-0.15535,45.3,1.9621785370920763,9.290237310701078,2.4441585875849587e-10,0.30161653276346145,11807.418159789508,8.36110426844041,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,316.6,1.9,,,144.0,9.29,47.8,8.98,38.4,0.0044592,-0.16252,45.2,1.9005408747512038,9.290253374562205,1.1092120351166408e-10,0.32504388919080934,11917.782128523948,-2.6498584262207325,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,316.9,1.9,,,144.0,9.29,47.8,8.98,38.4,0.004645,-0.159174,45.3,1.8880927636613982,9.290256739754417,9.397260496340111e-11,0.32977368577394317,11932.713930896669,-1.934563323151535,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,315.6,1.835,1.924,0.954,72.0,9.29,47.8,8.98,38.4,0.0060385,-0.15535,45.3,1.9621785370920763,9.290237310701078,2.4441585875849587e-10,0.30161653276346145,11807.418159789508,8.36110426844041,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM345PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,345.0,314.4,1.88,,,72.0,9.29,47.8,8.98,38.4,0.006781699999999999,-0.161564,45.3,2.0089404029107016,9.290002658998327,4.310901199815842e-10,0.28609353656839626,999999.3199480149,8.956604392269426,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS345M-72,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.7,1.8354959999999998,1.924,0.954,72.0,9.31,47.3,8.87,38.9,0.00533463,-0.155617,45.0,1.9165718991106726,9.310002677391912,1.7814971528056764e-10,0.2875230415165512,999999.7651023892,4.405982828558466,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS345M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,345.0,316.7,1.8354959999999998,1.924,0.954,72.0,9.31,47.3,8.87,38.9,0.00533463,-0.155617,45.0,1.9165718991106726,9.310002677391912,1.7814971528056764e-10,0.2875230415165512,999999.7651023892,4.405982828558466,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-60HL,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,323.4,1.63,,,20.0,11.0,41.4,10.2,34.31,0.005204650000000001,-0.12741264,45.6,1.6413495082282852,11.019403625743589,1.1846025405581306e-10,0.20443590274327522,115.89560628860306,6.834407479355457,-0.39292,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-60HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,324.4,1.63,,,20.0,11.0,41.4,10.2,34.31,0.00783464,-0.13340736,45.1,1.6738588038048068,11.018155102485288,1.9352425163520683e-10,0.19756038947032012,119.69992083389823,5.814915506768996,-0.38696,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,323.9,1.77,,,22.0,10.34,43.41,9.52,36.77,0.0032980464000000004,-0.136446312,45.2,1.6993991702402027,10.355177417219021,7.98089330715112e-11,0.1412209588637852,96.21035674468463,2.064882901149099,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-66HB,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,324.4,1.77,,,22.0,10.25,43.65,9.54,36.69,0.0037903475,-0.13004644499999998,45.3,1.680394606999686,10.26350492437154,5.206325503949251e-11,0.1829074341750324,138.82352566689963,4.030532090033823,-0.37224,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.7,1.82,,,22.0,10.28,43.67,9.48,36.92,0.0067091392,-0.13821555000000002,45.7,1.7998484640137635,10.292300270088637,2.869995865906251e-10,0.13016926517535307,108.78948761273433,11.954980586515196,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,323.8,1.77,,,22.0,10.34,43.41,9.52,36.77,0.0033843854000000003,-0.1263231,45.5,1.6866836451680143,10.355623232251475,6.580778279658107e-11,0.14419974016595305,95.43641788308905,8.57659915685356,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,324.6,1.68,,,20.0,11.4,39.71,10.59,33.05,0.0060306000000000005,-0.11039380000000001,45.4,1.5438063944054947,11.418716781666847,7.459184501991044e-11,0.18070466940927898,110.0634161439952,13.623180063835058,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,324.6,1.68,,,20.0,11.11,40.26,10.4,33.66,0.007516914899999999,-0.11736595200000001,45.4,1.5900994582291343,11.121103692751309,1.0980312350015478e-10,0.1662314223385323,166.3258505558653,11.760844413860708,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,324.7,1.68,,,20.0,11.4,39.71,10.59,33.05,0.0057456,-0.1115851,45.3,1.5302132925624787,11.419276450601053,5.933076211158486e-11,0.18351849751037447,108.53195610268286,10.377188265181635,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM350M-72,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,322.0,1.8354959999999998,1.924,0.954,72.0,9.38,47.5,8.94,39.1,0.006097000000000001,-0.1463,44.9,1.9170672893016318,9.380002659687122,1.6274204378196544e-10,0.2834962355820467,999999.877089053,10.608991314896452,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,319.6,1.8354959999999998,1.924,0.954,72.0,9.38,47.5,8.94,39.1,0.006472200000000001,-0.1463,46.2,1.9395575125058495,9.380002587606858,2.169081834319167e-10,0.27579913509386433,999999.8399129693,13.159735772377873,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,319.6,1.8354959999999998,1.924,0.954,72.0,9.38,47.5,8.94,39.1,0.006472200000000001,-0.1463,46.2,1.9395575125058495,9.380002587606858,2.169081834319167e-10,0.27579913509386433,999999.8399129693,13.159735772377873,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,322.1,1.9,,,144.0,9.38,47.5,8.94,39.1,0.0048776,-0.15960000000000002,45.0,1.8892455785298403,9.380002748883545,1.1298838775782795e-10,0.29301799542893664,999999.8783891045,-1.4644372717253165,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.6,1.9,,,144.0,9.38,47.5,8.94,39.1,0.0052528,-0.15722500000000003,45.3,1.895496660450698,9.380002728840166,1.2275627196502269e-10,0.2908786122193301,999999.878112939,0.6551433499737034,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.1,1.9,,,144.0,9.38,47.5,8.94,39.1,0.0055342,-0.15675000000000003,45.3,1.9171411105529161,9.380002659448747,1.6289738636411927e-10,0.28347097083364314,999999.9397890115,3.255657583234082,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.5,1.9,,,144.0,9.38,47.5,8.94,39.1,0.005440400000000001,-0.16007500000000002,44.9,1.9217588496989606,9.380002644647515,1.7288993033553804e-10,0.28189058624086966,999999.9260455666,1.594192515383705,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,322.0,1.8354959999999998,1.924,0.954,72.0,9.38,47.5,8.94,39.1,0.008132460000000001,-0.14725000000000002,44.9,1.9554023756596046,9.380002536841653,2.6452098220896603e-10,0.27037635639769153,999999.701988418,14.035390885201906,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.7,1.88,,,72.0,9.38,47.5,8.94,39.1,0.006003200000000001,-0.14535,45.0,1.9125072963973127,9.38000267430243,1.5340623705920546e-10,0.285056856971982,999999.951033648,10.82011840484656,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350N-60H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.1,1.63,,,20.0,10.76,40.73,10.38,33.72,0.0040792236,-0.1256145784,44.85,1.677956602566381,10.76013226239405,3.0887876729119957e-10,0.13359495249860995,10868.442410847429,15.363795170871029,-0.442985,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350N-60H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,317.5,1.63,,,20.0,10.76,40.73,10.38,33.72,0.0040665268,-0.13158641100000001,46.05,1.7284565021831697,10.760117018656508,6.277486527190919e-10,0.11728037460841917,10784.127283078768,16.57443261292051,-0.46864,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350P-72,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,320.3,1.835,1.924,0.954,72.0,9.36,48.0,9.07,38.6,0.006084,-0.156,45.3,1.973698286308466,9.360219838656443,2.565259835329224e-10,0.277979600620328,11835.485897423983,8.719472764708593,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350PP-72,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,320.3,1.835,1.924,0.954,72.0,9.36,48.0,9.07,38.6,0.006084,-0.156,45.3,1.973698286308466,9.360219838656443,2.565259835329224e-10,0.277979600620328,11835.485897423983,8.719472764708593,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,321.3,1.9,,,144.0,9.36,48.0,9.07,38.6,0.0044928,-0.1632,45.2,1.9117088083950269,9.360261152495044,1.1658181724501344e-10,0.30158029793735547,10808.994294419115,-2.3179007368176396,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,321.6,1.9,,,144.0,9.36,48.0,9.07,38.6,0.00468,-0.15984,45.3,1.8991755102979955,9.360263925698034,9.87802006438014e-11,0.3064110650474688,10866.737716495838,-1.5990321862079986,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350PP-72-J4,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,320.3,1.835,1.924,0.954,72.0,9.36,48.0,9.07,38.6,0.006084,-0.156,45.3,1.973698286308466,9.360219838656443,2.565259835329224e-10,0.277979600620328,11835.485897423983,8.719472764708593,-0.426,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM350PP-72-V,Jinko Solar Co Ltd,Multi-c-Si,0,350.0,319.1,1.88,,,72.0,9.36,48.0,9.07,38.6,0.0068328,-0.16224,45.3,2.020821992124958,9.360002455891038,4.5248332761225653e-10,0.26226679490348814,999999.3436545539,9.318657938221232,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS350M-72,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.4,1.8354959999999998,1.924,0.954,72.0,9.38,47.5,8.94,39.1,0.00537474,-0.15627500000000003,45.0,1.9258280954693376,9.380002631605171,1.8215931728566174e-10,0.28049791915598943,999999.9111542825,4.5304160907713085,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS350M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,350.0,321.4,1.8354959999999998,1.924,0.954,72.0,9.38,47.5,8.94,39.1,0.00537474,-0.15627500000000003,45.0,1.9258280954693376,9.380002631605171,1.8215931728566174e-10,0.28049791915598943,999999.9111542825,4.5304160907713085,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,328.6,1.77,,,22.0,10.41,43.49,9.63,36.87,0.0033203736,-0.136697768,45.2,1.698894203247533,10.423082736871091,7.649718775417053e-11,0.1378366155207956,109.67729404343726,1.6444120172916912,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-66HB,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,329.1,1.77,,,22.0,10.37,43.68,9.66,36.76,0.0038347222999999997,-0.13013582399999998,45.3,1.6818893244318645,10.382857049350488,5.299781781005788e-11,0.17571567891332088,141.72548826480775,4.079033401722243,-0.37224,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.5,1.82,,,22.0,10.36,43.71,9.59,37.02,0.0067613504,-0.13834215000000002,45.7,1.7994925595056033,10.370409645821418,2.8274749130626767e-10,0.12229989593720916,121.71662502398603,11.736303068078925,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,328.6,1.77,,,22.0,10.41,43.49,9.63,36.87,0.0034072971,-0.1265559,45.5,1.68624334617726,10.423484778862644,6.310960305158539e-11,0.1407649561273124,108.66794462902828,8.13321124689111,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,329.4,1.68,,,20.0,11.52,39.81,10.71,33.15,0.00609408,-0.11067180000000001,45.4,1.5474762486178564,11.538180601147921,7.517180755374894e-11,0.1775518020828761,112.50435376751625,13.595050583763891,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,329.3,1.68,,,20.0,11.21,40.41,10.5,33.81,0.0075845739,-0.117803232,45.4,1.5961457849904905,11.220679940134053,1.1107812963082761e-10,0.1627341812526603,170.8109023462334,11.782085905748785,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,329.5,1.68,,,20.0,11.52,39.81,10.71,33.15,0.00580608,-0.11186610000000001,45.3,1.5300860933827414,11.538889396051413,5.608492359527038e-11,0.1811136096118374,110.455029640867,9.781714329844059,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM355M-72,Jinko Solar Co Ltd,Multi-c-Si,0,355.0,326.8,1.8354959999999998,1.924,0.954,72.0,9.45,47.8,9.04,39.3,0.0061425,-0.147224,44.9,1.931408797249891,9.450002550931817,1.6872277416418356e-10,0.26989065816035235,999999.2844750468,10.865364460700569,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72B,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,324.3,1.8354959999999998,1.924,0.954,72.0,9.45,47.8,9.04,39.3,0.0065205,-0.147224,46.2,1.9540764845704954,9.450002476691786,2.2483073211993677e-10,0.2620229054252999,999999.2803461225,13.420313606708849,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72B-J4,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,324.3,1.8354959999999998,1.924,0.954,72.0,9.45,47.8,9.04,39.3,0.0065205,-0.147224,46.2,1.9540764845704954,9.450002476691786,2.2483073211993677e-10,0.2620229054252999,999999.2803461225,13.420313606708849,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.8,1.9,,,144.0,9.45,47.8,9.04,39.3,0.004914,-0.160608,45.0,1.9034066856737186,9.450002642668487,1.1723301368577594e-10,0.279609942152133,999999.290887014,-1.230411128471937,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.4,1.9,,,144.0,9.45,47.8,9.04,39.3,0.005292,-0.158218,45.3,1.909707187842903,9.450002622025417,1.2735976092009321e-10,0.27742309385812447,999999.2896091008,0.893867608097494,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,325.8,1.9,,,144.0,9.45,47.8,9.04,39.3,0.0055755,-0.15774,45.3,1.9315257620621775,9.450002550548689,1.6897582488828027e-10,0.2698500607141811,999999.2841309307,3.499201656529207,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.2,1.9,,,144.0,9.45,47.8,9.04,39.3,0.005481000000000001,-0.161086,44.9,1.9361921923375642,9.450002535263927,1.793607670202769e-10,0.2682303842521408,999999.2466682355,1.8346613655782131,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.7,1.8354959999999998,1.924,0.954,72.0,9.45,47.8,9.04,39.3,0.00819315,-0.14818,44.9,1.970067982788847,9.45000242433015,2.7421403792357523e-10,0.25647239858364473,999999.2759383087,14.300005586667584,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.5,1.88,,,72.0,9.45,47.8,9.04,39.3,0.006048,-0.14626799999999998,45.0,1.9268070796649897,9.450002566005505,1.59039159175977e-10,0.2714878734234053,999999.2855800008,11.076664858453224,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,355.0,326.0,1.9,,,144.0,9.43,48.2,9.12,38.9,0.0045264,-0.16388000000000003,45.2,1.921023936056104,9.430235997022606,1.1954914152467607e-10,0.2982501776111828,11917.539567973638,-2.178869687494905,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM355PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,355.0,326.4,1.9,,,144.0,9.43,48.2,9.12,38.9,0.0047150000000000004,-0.160506,45.3,1.9084133476269376,9.43023908237993,1.0128434342697535e-10,0.3029923320873733,11950.78382807588,-1.4596892856345653,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS355M-72,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.1,1.8354959999999998,1.924,0.954,72.0,9.45,47.8,9.04,39.3,0.00541485,-0.157262,45.0,1.9402748385630872,9.45000252189183,1.889242101593921e-10,0.2668133340446318,999999.2816260356,4.775472552640759,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKMS355M-72-J4,Jinko Solar Co Ltd,Mono-c-Si,0,355.0,326.1,1.8354959999999998,1.924,0.954,72.0,9.45,47.8,9.04,39.3,0.00541485,-0.157262,45.0,1.9402748385630872,9.45000252189183,1.889242101593921e-10,0.2668133340446318,999999.2816260356,4.775472552640759,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,333.4,1.77,,,22.0,10.48,43.58,9.74,36.97,0.0033427008000000004,-0.13698065599999998,45.2,1.6986766551606636,10.491141474565936,7.319727914304724e-11,0.1355227746495867,127.4767251067655,1.2120932588338658,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360M-66HB,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,333.9,1.77,,,22.0,10.49,43.7,9.78,36.81,0.0038790971000000002,-0.13019541,45.3,1.6827293880849026,10.502317797343787,5.3717863822983495e-11,0.17002453280222513,144.79515403496885,4.092613288893692,-0.37224,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,331.2,1.82,,,22.0,10.44,43.75,9.7,37.12,0.0068135615999999994,-0.13846875,45.7,1.799215494972115,10.44866799204298,2.78810292764944e-10,0.11457980193847944,138.00349177018822,11.526843722356965,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,331.5,1.87,,,22.0,10.55,43.41,9.85,36.55,0.0037431400000000003,-0.1314129225,46.62,1.6714454838614088,10.561742325856578,5.402255824568655e-11,0.16970962654809016,152.47716570161413,2.448598270987624,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,334.2,1.68,,,20.0,11.64,39.91,10.83,33.24,0.00615756,-0.1109498,45.4,1.5509077070502184,11.65774925415372,7.545109364606584e-11,0.17553562925082078,115.11665395054253,13.53084924068827,-0.374,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jinko Solar Co Ltd JKM360M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,334.1,1.68,,,20.0,11.31,40.57,10.6,33.97,0.0076522329,-0.118269664,45.4,1.6026331688678526,11.320256810051456,1.1243715244303106e-10,0.15916262978765622,175.505773601667,11.809672638384999,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,334.3,1.68,,,20.0,11.64,39.91,10.83,33.24,0.00586656,-0.1121471,45.3,1.5483541298330843,11.65785136898275,7.231039213759665e-11,0.17605189660699364,114.79478696298712,11.95702919643198,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360M-72,Jinko Solar Co Ltd,Multi-c-Si,0,360.0,331.5,1.8354959999999998,1.924,0.954,72.0,9.51,48.0,9.12,39.5,0.0061815,-0.14784,44.9,1.942531487661776,9.510002394064617,1.765026750986277e-10,0.2516951664042923,999993.782934163,11.213002408936106,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,331.5,1.9,,,144.0,9.51,48.0,9.12,39.5,0.0049452,-0.16128,45.0,1.9144101368075515,9.510002487686597,1.2277617793909905e-10,0.261543956470533,999969.3821435055,-0.9126275367315569,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,331.1,1.9,,,144.0,9.51,48.0,9.12,39.5,0.005325600000000001,-0.15888,45.3,1.9207491421846303,9.510002466531375,1.3336781740681011e-10,0.2593238803300399,999994.7080780318,1.2178814258802422,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,330.5,1.9,,,144.0,9.51,48.0,9.12,39.5,0.0056109,-0.1584,45.3,1.9427082102171405,9.510002393476716,1.7689986394999688e-10,0.25163327381518386,999993.7885424373,3.829565850662968,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,331.0,1.9,,,144.0,9.51,48.0,9.12,39.5,0.0055158,-0.16176000000000001,44.9,1.9474207110740622,9.510002377800411,1.87799214705767e-10,0.2499828399445665,999993.7756099736,2.1608484531141534,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,331.2,1.88,,,72.0,9.51,48.0,9.12,39.5,0.0060864000000000005,-0.14687999999999998,45.0,1.9378935468055776,9.510002409533708,1.6636726513318338e-10,0.2533194879982011,999977.1661153815,11.424610063616552,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,360.0,332.2,1.85,,,22.0,10.44,44.12,9.86,36.51,0.0049630716,-0.13299444559999998,46.62,1.6805303076108573,10.447011318359433,4.094733812300523e-11,0.2495022880407826,371.51414470975567,0.49301134516839973,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM360PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,360.0,330.7,1.9,,,144.0,9.51,48.5,9.21,39.1,0.0045648,-0.16490000000000002,45.2,1.9332735071539087,9.510233502196852,1.2102277380178338e-10,0.2928971926103868,11929.039390561957,-2.1489135587336428,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM360PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,360.0,331.1,1.9,,,144.0,9.51,48.5,9.21,39.1,0.0047550000000000005,-0.161505,45.3,1.9206267885450243,9.510251073377976,1.0259259222610706e-10,0.2975281260732109,11269.599207356177,-1.4247945525470553,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,338.2,1.77,,,22.0,10.55,43.66,9.85,37.06,0.0033650280000000004,-0.137232112,45.2,1.6981404516006566,10.559258249194606,7.010283972158171e-11,0.13336396783481996,151.97148454591937,0.7893425419436485,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-66HB,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,338.7,1.77,,,22.0,10.61,43.73,9.9,36.87,0.003923471899999999,-0.13028478899999998,45.3,1.6840086816956088,10.621779900416568,5.448450618438397e-11,0.16431999579328121,148.00084111456653,4.113042768676835,-0.37224,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.0,1.82,,,22.0,10.52,43.83,9.81,37.21,0.0068657728,-0.13872194999999998,45.7,1.799465498609858,10.527395368687115,2.7079648075110033e-10,0.11232653502110913,159.78583875723922,11.181760234376835,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,338.1,1.77,,,22.0,10.55,43.66,9.85,37.06,0.0034531205000000007,-0.12705059999999999,45.5,1.6856184056216137,10.559577668416368,5.789516284492854e-11,0.13619420546769032,150.02073702302752,7.231439261648464,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.1,1.85,,,22.0,10.94,43.32,10.14,36.0,0.0036631496,-0.12988678920000002,46.84,1.6584360232596882,10.961018768468394,4.788292976930419e-11,0.21704239909337542,112.96779194677582,2.194385820556289,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,337.0,1.85,,,22.0,10.79,43.92,9.97,36.61,0.0050857586,-0.1316207736,46.72,1.6923345397685967,10.81146061065327,5.5689943811080366e-11,0.20855162403992628,104.85591837026547,3.4443087133892063,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.3,1.87,,,22.0,10.65,43.49,9.97,36.61,0.0037786200000000003,-0.1316551025,46.62,1.6719957412558026,10.660519171253146,5.2599995825845894e-11,0.16977290070904202,171.88439168682123,2.1402647707548317,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.1,1.85,,,22.0,10.94,43.32,10.14,36.0,0.0036631496,-0.12988678920000002,46.84,1.6584360232596882,10.961018768468394,4.788292976930419e-11,0.21704239909337542,112.96779194677582,2.194385820556289,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6TL3,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,338.9,1.68,,,20.0,11.76,40.01,10.95,33.34,0.00622104,-0.11122780000000002,45.4,1.521334394310328,11.77856758710541,4.327750243072473e-11,0.17917876686822226,113.48498332700288,8.458036992768621,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6TL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,338.9,1.68,,,20.0,11.41,40.72,10.7,34.12,0.0077198919,-0.11870694400000001,45.4,1.6086886690488502,11.419853161880056,1.1373483054953712e-10,0.15579400061619234,180.41006633325222,11.831786261308403,-0.37469,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-6TL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,339.1,1.68,,,20.0,11.76,40.01,10.95,33.34,0.00592704,-0.11242810000000002,45.3,1.5291348235204114,11.778248343923229,4.950260424576383e-11,0.17760796087065137,114.45803768092873,8.494891108267568,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365M-72,Jinko Solar Co Ltd,Multi-c-Si,0,365.0,336.3,1.8354959999999998,1.924,0.954,72.0,9.57,48.2,9.2,39.7,0.0062205,-0.148456,44.9,1.9543046187037185,9.570185706095195,1.8599998610834865e-10,0.23108802988501714,11908.693986917911,11.629560262398709,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.3,1.9,,,144.0,9.57,48.2,9.2,39.7,0.0049764,-0.161952,45.0,1.9260600485314754,9.570193165826428,1.2955072111790465e-10,0.24110661668126812,11945.145272994423,-0.5321052996377151,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,335.8,1.9,,,144.0,9.57,48.2,9.2,39.7,0.005359200000000001,-0.15954200000000002,45.3,1.9324416075241322,9.5701914773905,1.4071174179868128e-10,0.23884310794746955,11937.348304251705,1.6059950165484251,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,335.3,1.9,,,144.0,9.57,48.2,9.2,39.7,0.0056463,-0.15906,45.3,1.954553963132428,9.570185585745298,1.8658614722855885e-10,0.23100012738947492,11911.883862420744,4.225488887691133,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,335.7,1.9,,,144.0,9.57,48.2,9.2,39.7,0.005550600000000001,-0.16243400000000002,44.9,1.959318758540427,9.570184299709094,1.9811811006747947e-10,0.22931023240712375,11907.255672558813,2.551824821910251,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,335.9,1.88,,,72.0,9.57,48.2,9.2,39.7,0.0061248000000000006,-0.147492,45.0,1.949626047101024,9.57018695826083,1.7531094403115102e-10,0.23274744021075544,11913.875379297888,11.841455150636513,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.4,1.85,,,22.0,11.03,43.95,10.2,35.79,0.0044199416,-0.1323804765,46.64,1.6776256405941958,11.059947975640005,4.469596207061323e-11,0.29918938683923446,110.19305632805562,1.0076582460717847,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,336.9,1.85,,,22.0,10.52,44.33,9.94,36.72,0.0050011028,-0.13362746539999998,46.62,1.6890362505703196,10.526664685896264,4.16053838667678e-11,0.2446079794842179,386.1061175507938,0.5590707872309346,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,365.0,335.9,1.85,,,22.0,11.03,43.95,10.2,35.79,0.0043138329999999996,-0.13260769800000002,46.58,1.6884276204023627,11.059437526744876,5.2867761361771054e-11,0.29690204170733486,111.24676279492236,2.218239101944506,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM365PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,365.0,335.5,1.9,,,144.0,9.58,48.8,9.29,39.3,0.0045984,-0.16592,45.2,1.9453860041674669,9.580195323542366,1.2216380448522993e-10,0.28825357231963156,14137.950759628862,-2.1329525636305187,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM365PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,365.0,335.8,1.9,,,144.0,9.58,48.8,9.29,39.3,0.00479,-0.162504,45.3,1.9326268085638105,9.580198326925656,1.035187271772643e-10,0.2930725171264784,14156.622919730182,-1.411935760636067,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,342.9,1.77,,,22.0,10.62,43.75,9.96,37.15,0.0033873551999999995,-0.137515,45.2,1.6978880161517027,10.627467404360633,6.702209022472855e-11,0.1322255813123815,188.0487009857333,0.35463649958711074,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.7,1.82,,,22.0,10.6,43.92,9.92,37.3,0.006917984,-0.1390068,45.7,1.7999792681506654,10.606207904407846,2.62463382943389e-10,0.1111122322008892,189.72420173127355,10.819597441114643,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,342.9,1.77,,,22.0,10.62,43.75,9.96,37.15,0.0034760322,-0.1273125,45.5,1.68538910596191,10.627748844459479,5.5345460065947774e-11,0.135017278150908,185.04481735265713,6.7675024458287645,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.8,1.85,,,22.0,11.03,43.41,10.25,36.1,0.0036932851999999998,-0.1301566371,46.84,1.6602537613478823,11.049088790333357,4.719795236122956e-11,0.21318883080608872,123.18605741261338,1.9985359230803876,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,341.8,1.85,,,22.0,10.9,44.02,10.08,36.71,0.005137606,-0.1319204566,46.72,1.6958609964927218,10.920952938088337,5.6029755878031825e-11,0.20512650166705124,106.70956373707963,3.407452380662037,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,341.0,1.87,,,22.0,10.75,43.58,10.09,36.67,0.0038140999999999995,-0.131927555,46.62,1.6727863167156083,10.75931795996961,5.109485721050997e-11,0.17081216935174526,197.0636106601293,1.8144021629424225,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.8,1.85,,,22.0,11.03,43.41,10.25,36.1,0.0036932851999999998,-0.1301566371,46.84,1.6602537613478823,11.049088790333357,4.719795236122956e-11,0.21318883080608872,123.18605741261338,1.9985359230803876,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,341.1,1.92,,,72.0,9.61,48.5,9.28,39.9,0.004288943,-0.15003475,45.4,1.894561708929262,9.610159687025755,7.325153877934582e-11,0.23675360323802405,14247.898552703904,3.2971918716697717,-0.39107,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,341.0,1.9,,,144.0,9.61,48.5,9.28,39.9,0.004805,-0.16296,45.0,1.936900874738605,9.610150023677175,1.2818619205593095e-10,0.2213258057747313,14177.392876778504,-0.6260788442285661,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.6,1.9,,,144.0,9.61,48.5,9.28,39.9,0.005381599999999999,-0.160535,45.3,1.9474781133331887,9.610147600679461,1.4686027191317543e-10,0.21747146391982305,14158.841778036964,1.9225056793224156,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.6,1.95,,,24.0,9.61,48.5,9.28,39.9,0.005256189499999999,-0.1503791,45.6,1.91583417722554,9.610154852938415,9.733347067519273e-11,0.22900217156934646,14211.609649981767,5.320872237683115,-0.39174,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.4,1.95,,,24.0,10.15,47.8,9.59,38.58,0.005667963000000001,-0.15627254,45.6,1.8754277244141,10.154779647256897,8.610541124850031e-11,0.3784525869809244,803.6772405584916,-1.5668153101598417,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,342.7,2.01,,,24.0,10.15,47.8,9.59,38.58,0.0049532000000000005,-0.14101,46.3,1.7628996662145933,10.158163024722409,1.68686128876091e-11,0.40341589477119405,501.6119889231043,-4.217231486008746,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.0,1.9,,,144.0,9.61,48.5,9.28,39.9,0.005765999999999999,-0.16005,45.3,1.9718200574942264,9.610167855352422,1.9970765835130273e-10,0.20827729585701032,11924.248637862407,4.751369060354364,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.4,1.9,,,144.0,9.61,48.5,9.28,39.9,0.005765999999999999,-0.163445,44.9,1.9786567675621316,9.610165973851624,2.1742213909878021e-10,0.20578468337614364,11915.10102483998,3.2652896536652163,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,339.7,1.92,,,72.0,9.61,48.5,9.28,39.9,0.0064386999999999995,-0.150835,45.6,1.9684072187421044,9.610173166424092,1.91368047174499e-10,0.20946708177429757,11624.554771634466,10.736708239186001,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.2,1.92,,,72.0,9.61,48.5,9.28,39.9,0.004805,-0.1455,45.5,1.9247713949347693,9.610152839718547,1.0947410579751023e-10,0.22574523875728117,14194.050165767643,9.972829725080164,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.7,1.88,,,72.0,9.61,48.5,9.28,39.9,0.0061503999999999994,-0.14841,45.0,1.96487283365096,9.610176199219437,1.8307084738046836e-10,0.21073060800855942,11493.381818467888,12.195718270827102,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,341.1,1.85,,,22.0,11.13,44.14,10.32,35.86,0.004460013600000001,-0.1329527698,46.64,1.6804253580687933,11.158181243575322,4.2220732696174054e-11,0.30742381377594796,121.41504930037904,0.4605986109752509,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,341.7,1.85,,,22.0,10.6,44.54,10.02,36.93,0.005039134,-0.1342604852,46.62,1.6975431308763487,10.606327731586946,4.226854235983581e-11,0.23979199847942553,401.69138143695295,0.6246100305884712,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,370.0,340.7,1.85,,,22.0,11.13,44.14,10.32,35.86,0.004352943000000001,-0.1331809736,46.58,1.6912274822692193,11.157678462722755,4.9948549463969175e-11,0.3051684988868342,122.71365885349972,1.6664887425740045,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM370PP-72H,Jinko Solar Co Ltd,Multi-c-Si,0,370.0,340.2,1.9,,,144.0,9.63,49.1,9.37,39.5,0.0046224000000000005,-0.16694000000000003,45.2,1.9595589476596393,9.63018120465985,1.263309369521596e-10,0.26699771493719715,14189.394790682185,-1.9094319991817126,-0.409,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM370PP-72H-V,Jinko Solar Co Ltd,Multi-c-Si,0,370.0,340.6,1.9,,,144.0,9.63,49.1,9.37,39.5,0.004815000000000001,-0.16350300000000004,45.3,1.9467133922371915,9.630184313912432,1.0707904165048925e-10,0.27196679599282236,14209.651618198233,-1.1844824404175816,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,347.7,1.77,,,22.0,10.69,44.02,10.07,37.24,0.0034096824,-0.138363664,45.2,1.700966851389532,10.696328798299826,6.064578358162155e-11,0.14913231682842734,251.90003142622606,-0.5202313213946851,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.5,1.82,,,22.0,10.68,44.0,10.03,37.39,0.0069701952,-0.13926,45.7,1.8003914718149043,10.68499302289214,2.5541576230494727e-10,0.1088827390428984,232.898533030708,10.495427476463863,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,347.7,1.77,,,22.0,10.69,44.02,10.07,37.24,0.0034989439000000003,-0.1280982,45.5,1.688611713326734,10.696584949108406,5.0167066241908375e-11,0.15185194441196628,246.51630240637434,5.850457197267329,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.6,1.85,,,22.0,11.12,43.49,10.36,36.2,0.0037234207999999997,-0.13039650190000002,46.84,1.6619379636790133,11.137136822400322,4.67008729623664e-11,0.20842271823938316,135.2444806766348,1.8351267429811002,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,346.5,1.85,,,22.0,11.01,44.12,10.19,36.8,0.0051894534,-0.13222013959999998,46.72,1.6991483519969295,11.030559147886368,5.6161846377771184e-11,0.2029084926731746,108.66318649502293,3.34031607282165,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.7,1.87,,,22.0,10.85,43.66,10.21,36.73,0.0038495799999999996,-0.132169735,46.62,1.6734571426214289,10.858041416248733,4.983030065493519e-11,0.17081299527127852,230.47196600986115,1.5229574373176034,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.6,1.85,,,22.0,11.12,43.49,10.36,36.2,0.0037234207999999997,-0.13039650190000002,46.84,1.6619379636790133,11.137136822400322,4.67008729623664e-11,0.20842271823938316,135.2444806766348,1.8351267429811002,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.9,1.92,,,72.0,9.68,48.7,9.33,40.2,0.004320184,-0.15065345000000002,45.4,1.9036428776513847,9.680157814265648,7.505464124778438e-11,0.23208770583296423,14235.758962737254,3.439184593088283,-0.39107,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.8,1.9,,,144.0,9.68,48.7,9.33,40.2,0.0050336,-0.16363200000000003,45.0,1.9503573742325508,9.680147266486275,1.385124311918782e-10,0.21541780274628072,14159.536505984632,-0.08686419245073541,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.3,1.9,,,144.0,9.68,48.7,9.33,40.2,0.0054208,-0.16119700000000003,45.3,1.9569716121411842,9.680183625066828,1.506959098311056e-10,0.21262632858640831,11208.850831656537,2.075137553336093,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.4,1.95,,,24.0,9.68,48.7,9.33,40.2,0.005294476,-0.15099922000000002,45.6,1.9250036279943759,9.68015301540949,9.969254042063675e-11,0.22446515325601427,14200.043554363509,5.4627212380083146,-0.39174,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.1,1.95,,,24.0,10.23,48.0,9.65,38.86,0.0057126366,-0.1569264,45.6,1.8880025728904135,10.236535309409382,9.229563362720372e-11,0.36270162303799386,567.7524494753308,-1.0700385950300184,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,347.4,2.01,,,24.0,10.23,48.0,9.65,38.86,0.00499224,-0.14159999999999998,46.3,1.7744678411102937,10.239944082603774,1.808593584130927e-11,0.3877996888703224,398.94991177014236,-3.7284801289967238,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,344.7,1.9,,,144.0,9.68,48.7,9.33,40.2,0.0057112,-0.16071000000000002,45.3,1.9793397394791825,9.680166308297673,1.9963960793196256e-10,0.20476855996646956,11918.60983944105,4.699143497075429,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,346.2,1.956,,,144.0,9.68,48.7,9.33,40.2,0.0060983999999999995,-0.16558000000000003,45.1,1.9490887217028083,9.680147531937216,1.3627944212729634e-10,0.21587077478427344,14163.590735662217,-1.533011007392183,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,375.0,344.4,1.98,,,24.0,10.14,47.92,9.56,39.25,0.0056784,-0.1499896,45.3,1.920358480389038,10.146217691977977,1.4618858570379323e-10,0.3046883253874449,496.894976577682,7.34936458687042,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,346.4,1.95,,,24.0,10.23,48.0,9.65,38.86,0.0049996056,-0.1484304,45.5,1.840199217876623,10.237920467369168,4.761809840459711e-11,0.3731964271502346,482.0169606580704,-0.7153335640766587,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,375.0,344.3,1.98,,,24.0,9.92,47.92,9.56,39.25,0.0047615999999999995,-0.1543024,45.2,1.920695531234999,9.920170942107733,1.4488608442816799e-10,0.23913186889520616,13877.160227979371,4.506774382759091,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL-TV-Q,Jinko Solar Co Ltd,Mono-c-Si,1,375.0,343.7,1.98,,,24.0,9.92,47.92,9.56,39.25,0.0043205568,-0.14814468,45.2,1.926456111222995,9.920169650725036,1.5610860471950415e-10,0.23712780614744206,13865.6187517936,9.587744947159182,-0.42063,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,347.5,1.956,,,144.0,9.68,48.7,9.33,40.2,0.0061952,-0.156814,45.1,1.9067871026849026,9.680157067300819,7.828852020951523e-11,0.23096612989322207,14234.29371639852,-0.5505140335881381,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.5,1.95,,,24.0,10.23,48.0,9.65,38.86,0.0045999195,-0.1455696,45.3,1.8634515633533744,10.237237712414851,6.597974526458088e-11,0.3680786149925901,520.2533426362729,3.9940797879893504,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.2,1.9,,,144.0,9.68,48.7,9.33,40.2,0.0056144,-0.16411900000000001,44.9,1.9841931335826677,9.680164986808515,2.1202324723478142e-10,0.20303573338572586,11912.407708102743,3.019546800245909,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,344.5,1.92,,,72.0,9.68,48.7,9.33,40.2,0.0064856,-0.151457,45.6,1.9778036571099107,9.680167021314173,1.958607763718934e-10,0.20531346704714018,11899.309748748723,10.879509747769587,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,344.9,1.92,,,72.0,9.68,48.7,9.33,40.2,0.0048400000000000006,-0.1461,45.5,1.9339946355939583,9.680151011880975,1.1213482139819718e-10,0.221256437240906,14182.761695825307,10.121399237684962,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.4,1.88,,,72.0,9.68,48.7,9.33,40.2,0.0061952,-0.14902200000000002,45.0,1.9742537090338137,9.680169419466798,1.8737748462208733e-10,0.20656395842560724,11802.321136530481,12.340740049196096,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM375N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.9,1.85,,,22.0,11.23,44.32,10.44,35.92,0.004500085600000001,-0.1334949424,46.64,1.682863812293968,11.256223481829544,3.9897622685585577e-11,0.31558465731061697,135.14665073481487,-0.0797991524309681,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,346.4,1.85,,,22.0,10.68,44.74,10.1,37.13,0.0050771652,-0.1348633612,46.62,1.7056282702704266,10.686002670228337,4.290964930800143e-11,0.23519460766214337,418.4601809150562,0.6844756186213553,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM375N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,375.0,345.4,1.85,,,22.0,11.23,44.32,10.44,35.92,0.004392053,-0.1337240768,46.58,1.6936640313628926,11.255727626983031,4.720834032777839e-11,0.31336109415724106,136.78078956992334,1.1214797883452425,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,352.5,1.77,,,22.0,10.77,44.09,10.18,37.33,0.0034351992000000004,-0.138583688,45.2,1.701392951339108,10.774709865377794,5.925103061634472e-11,0.14545355110640834,332.6071223831339,-0.7791574517260097,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-66H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.2,1.82,,,22.0,10.76,44.11,10.14,37.48,0.0070224064,-0.13960815,45.7,1.801433407962412,10.763901176286822,2.465394892837161e-10,0.10966693884019149,302.4770592661475,10.100059766597093,-0.39847,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,352.4,1.77,,,22.0,10.77,44.09,10.18,37.33,0.0035251287000000004,-0.12830190000000002,45.5,1.689071605247902,10.774935874202374,4.902873496643791e-11,0.14813595732976198,323.2303376987096,5.577208752150723,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.3,1.85,,,22.0,11.21,43.58,10.47,36.3,0.0037535564,-0.1306663498,46.84,1.6638405159630263,11.225304441836226,4.608762538645639e-11,0.20470932557815746,149.9428456669291,1.651001425228729,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,351.3,1.85,,,22.0,11.12,44.22,10.3,36.9,0.0052413008,-0.13251982259999998,46.72,1.7026998499627621,11.140063778279384,5.6515164157831905e-11,0.19960730033114754,110.62887385851411,3.306855966470392,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.5,1.87,,,22.0,10.95,43.75,10.33,36.79,0.0038850599999999996,-0.1324421875,46.62,1.6743642193687898,10.956771760841262,4.8481275916829384e-11,0.1717701391332022,277.75391002910493,1.2136518153394804,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.3,1.85,,,22.0,11.21,43.58,10.47,36.3,0.0037535564,-0.1306663498,46.84,1.6638405159630263,11.225304441836226,4.608762538645639e-11,0.20470932557815746,149.9428456669291,1.651001425228729,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.6,1.92,,,72.0,9.75,48.9,9.39,40.5,0.004351425000000001,-0.15127215,45.4,1.913754620148124,9.750177970403232,7.794676130803413e-11,0.2204004829625871,12074.516798449167,3.6946058225515266,-0.39107,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.5,1.9,,,144.0,9.75,48.9,9.39,40.5,0.00507,-0.164304,45.0,1.960785295850611,9.750165294890511,1.438686319589553e-10,0.203824653921464,12022.715126497951,0.16104056970349337,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.1,1.9,,,144.0,9.75,48.9,9.39,40.5,0.0054600000000000004,-0.161859,45.3,1.967279280560973,9.750163552794275,1.5621350282384016e-10,0.2015356356219161,12014.320171959444,2.311980484461429,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.1,1.95,,,24.0,9.75,48.9,9.39,40.5,0.0053327625,-0.15161934,45.6,1.9352371573118072,9.750172211490359,1.0351006429502801e-10,0.21282889067656777,12049.625971540183,5.721547521946988,-0.39174,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,349.9,1.95,,,24.0,10.3,48.2,9.72,39.1,0.005751726,-0.15758026,45.6,1.8975818550832502,10.306178595525775,9.510885351511726e-11,0.35235520043656093,587.3922110179609,-0.8854156810754117,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,352.2,2.01,,,24.0,10.3,48.2,9.72,39.1,0.0050264,-0.14219,46.3,1.7833795987351748,10.309511171199855,1.8638850610393636e-11,0.37745549050127564,408.7605529261474,-3.5472034510962773,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,349.5,1.9,,,144.0,9.75,48.9,9.39,40.5,0.0057525,-0.16137,45.3,1.9898175780063672,9.750157467759733,2.0701038281591298e-10,0.19359143408554733,11986.710058059269,4.944853819261615,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.9,1.956,,,144.0,9.75,48.9,9.39,40.5,0.0061425,-0.16626000000000002,45.1,1.9595144045675303,9.750165631025782,1.4156031974465488e-10,0.2042726718739039,12024.688677891383,-1.287601855710001,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,380.0,349.1,1.98,,,24.0,10.23,47.96,9.66,39.36,0.0057288,-0.15011480000000002,45.3,1.922496351873097,10.234955178795728,1.4875840722760058e-10,0.29306295999362203,605.0305230944431,7.418480262631082,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,351.1,1.95,,,24.0,10.3,48.2,9.72,39.1,0.005033816,-0.14904886,45.5,1.8494875693942643,10.307531795968494,4.9065435165672825e-11,0.36285309638421265,496.21459042855633,-0.5306724821854849,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,380.0,349.0,1.98,,,24.0,10.02,47.96,9.66,39.36,0.0048096,-0.15443120000000002,45.2,1.9243823139773766,10.020163502863046,1.5035398607572915e-10,0.22613625392213144,13858.409748399095,4.7343358405163345,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL-TV-Q,Jinko Solar Co Ltd,Mono-c-Si,1,380.0,348.4,1.98,,,24.0,10.02,47.96,9.66,39.36,0.0043641108,-0.14826834,45.2,1.9301332256477584,10.020162202561126,1.6194373705729564e-10,0.22415025705932765,13846.824811042776,9.823135905845692,-0.42063,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,352.3,1.956,,,144.0,9.75,48.9,9.39,40.5,0.006240000000000001,-0.15745800000000001,45.1,1.9169346290753875,9.750177108438384,8.13217840547734e-11,0.21927979935546527,12071.587547432731,-0.30247225895093927,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.2,1.95,,,24.0,10.3,48.2,9.72,39.1,0.004631395,-0.14617614,45.3,1.872856276018198,10.306865261453916,6.796472120370483e-11,0.35773926692675206,536.7187688007454,4.184641176919741,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,349.9,1.9,,,144.0,9.75,48.9,9.39,40.5,0.005655,-0.164793,44.9,1.9947115813862693,9.750156131597157,2.1987592703410404e-10,0.19186653963169098,11981.577479783711,3.262207897287685,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,349.2,1.92,,,72.0,9.75,48.9,9.39,40.5,0.006532500000000001,-0.152079,45.6,1.9882267146864685,9.750157938036276,2.0297957974912465e-10,0.19415169006869443,11985.604385147963,11.135188992348725,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,349.7,1.92,,,72.0,9.75,48.9,9.39,40.5,0.004875000000000001,-0.1467,45.5,1.944266550718059,9.75016979819682,1.1639815371190945e-10,0.20964626097581399,12038.135020535727,10.389087668765395,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.9,1.88,,,72.0,9.75,48.9,9.39,40.5,0.0053625,-0.159414,45.2,1.9464827158533151,9.750169161089822,1.1977944703111468e-10,0.2088656080056016,12038.479476745924,1.7034158077940633,-0.394,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM380N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,359.5,1.329,,,18.0,13.23,36.58,12.47,30.48,0.00615195,-0.09682726,46.4,1.2989766702076522,13.244052556721853,7.657049103127588e-12,0.16166036625113436,152.19768849248274,-1.9132636518649986,-0.3077,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.6,1.85,,,22.0,11.33,44.51,10.56,35.99,0.004540157600000001,-0.1340672357,46.64,1.6857943709689565,11.354047724615356,3.7771215138995765e-11,0.3233983629791003,152.3679913959533,-0.6019749461642677,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,351.2,1.85,,,22.0,10.76,44.94,10.18,37.33,0.0051151964,-0.13546623719999998,46.62,1.7137145568086243,10.765686545873171,4.35555850854158e-11,0.23066949732873196,436.4695019560851,0.7439393466303134,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,350.2,1.85,,,22.0,11.33,44.51,10.56,35.99,0.004431163,-0.1342973524,46.58,1.6965964418109774,11.353558477566061,4.4699796263912585e-11,0.3212049248300913,154.47737827000387,0.5948642041362513,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM380N-72H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,380.0,344.6,1.95,,,24.0,10.36,47.75,9.61,39.55,0.0051180472,-0.15308554500000002,46.7,1.997975588046941,10.37500553259626,4.2063325727229895e-10,0.2295631714063665,158.4931819637166,14.058324757790075,-0.44106,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,357.3,1.77,,,22.0,10.83,44.17,10.29,37.42,0.0034543368000000004,-0.138835144,45.2,1.700447439207226,10.832318606794303,5.636984162082857e-11,0.1434370531589802,669.981363678155,-1.2411044144620123,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,357.2,1.77,,,22.0,10.83,44.17,10.29,37.42,0.0035447673000000004,-0.1285347,45.5,1.688198504802509,10.832499900481737,4.667099124853944e-11,0.14607328435185302,632.814676808814,5.089729480193958,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.1,1.85,,,22.0,11.3,43.66,10.58,36.39,0.003783692,-0.13090621460000001,46.84,1.6653612849861432,11.313526136008083,4.5479389320711595e-11,0.20119426541618887,168.08164513762637,1.4672782142533864,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,356.0,1.85,,,22.0,11.22,44.34,10.4,37.02,0.005288434800000001,-0.1328794422,46.72,1.707179122385079,11.239570637062103,5.694583513319827e-11,0.19625657565198437,112.51543772937536,3.2930039172355214,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.3,1.87,,,22.0,11.05,43.83,10.45,36.85,0.00392054,-0.1326843675,46.62,1.6751514893524568,11.055444855905403,4.735652659397352e-11,0.1717157259492275,348.4865053071862,0.9384556110368802,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.1,1.85,,,22.0,11.3,43.66,10.58,36.39,0.003783692,-0.13090621460000001,46.84,1.6653612849861432,11.313526136008083,4.5479389320711595e-11,0.20119426541618887,168.08164513762637,1.4672782142533864,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.4,1.92,,,72.0,9.92,49.1,9.44,40.8,0.004427296,-0.15189085000000002,45.4,1.9149658990518983,9.92056289787882,7.255988583376145e-11,0.26132094649286086,4605.284259809922,2.957063578508254,-0.39107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72H,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.3,1.9,,,144.0,9.92,49.1,9.44,40.8,0.00496,-0.16497600000000004,45.0,1.9559288441195597,9.92000360924849,1.2426353055585537e-10,0.2519845961073837,692639.6158280178,-1.1286906408056796,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HB,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.8,1.9,,,144.0,9.92,49.1,9.44,40.8,0.0055552,-0.16252100000000003,45.3,1.966537344007654,9.92000357194244,1.422838137667909e-10,0.24958664876060319,693221.0364073343,1.4017102745868815,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.9,1.95,,,24.0,9.92,49.1,9.44,40.8,0.005425744,-0.15223946000000002,45.6,1.9354903886313477,9.92025704340897,9.528307328982146e-11,0.2566324078838842,9904.147601963361,4.8717792664170245,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.6,1.95,,,24.0,10.38,48.4,9.78,39.37,0.005796399600000001,-0.15823412,45.6,1.9098969935255934,10.3877300761108,1.0145871308303004e-10,0.338170611325601,454.0978819172747,-0.4230637997549664,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,356.9,2.01,,,24.0,10.38,48.4,9.78,39.37,0.005065440000000001,-0.14278,46.3,1.7947180193258367,10.391099818964229,1.988855966035082e-11,0.3633917759427284,339.8259642069477,-3.092231913695489,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HB-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.2,1.9,,,144.0,9.92,49.1,9.44,40.8,0.005952,-0.16203000000000004,45.3,1.9909216891765333,9.92000348983504,1.9318008910857575e-10,0.24409398600991372,693938.4291519163,4.202200467883913,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.7,1.956,,,144.0,9.92,49.1,9.44,40.8,0.0062496,-0.16694000000000003,45.1,1.958642226466559,9.92000360226826,1.286609858765028e-10,0.2513707784384574,692293.5866089509,-2.1837768635572,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,385.0,353.8,1.98,,,24.0,10.32,48.1,9.76,39.5,0.0057792,-0.15055300000000002,45.3,1.9272625791205253,10.323759818924401,1.486938590342082e-10,0.2885028067820545,791.886380706946,7.333180662842463,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.9,1.95,,,24.0,10.38,48.4,9.78,39.37,0.0050729136,-0.14966732,45.5,1.8613705401324583,10.389098814855966,5.2334356247545084e-11,0.34872357740870574,397.82663021755667,-0.06719257404316809,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,385.0,353.8,1.98,,,24.0,10.08,48.1,9.76,39.5,0.0048384000000000005,-0.15488200000000002,45.2,1.9344989157661254,10.080141747866088,1.6028050465160025e-10,0.1956379257909144,13912.193188946689,5.224290925664127,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL-TV-Q,Jinko Solar Co Ltd,Mono-c-Si,1,385.0,353.1,1.98,,,24.0,10.08,48.1,9.76,39.5,0.0043902432,-0.14870115,45.2,1.9401906349417775,10.08014040761568,1.7240850036910824e-10,0.193619516081978,13900.150443798177,10.324875119546594,-0.42063,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,357.1,1.956,,,144.0,9.92,49.1,9.44,40.8,0.0063488,-0.15810200000000002,45.1,1.9177732223908581,9.920520407794015,7.534065567183068e-11,0.26067852263444974,4969.049331913441,-1.0526432843824682,-0.372,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.0,1.95,,,24.0,10.38,48.4,9.78,39.37,0.0046673669999999995,-0.14678268,45.3,1.884894019242673,10.388426152377964,7.244363710364226e-11,0.3435949157759238,423.2673750147625,4.663675224251781,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72H-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.7,1.9,,,144.0,9.92,49.1,9.44,40.8,0.005952,-0.16546700000000003,44.9,1.9977640608702885,9.920003471278878,2.1020649906892513e-10,0.24255748337834182,693262.6221459823,2.7196046344732485,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,353.9,1.92,,,72.0,9.92,49.1,9.44,40.8,0.0066464,-0.152701,45.6,1.987516000177193,9.920003493325119,1.8518653881680103e-10,0.24485953269503705,695416.211891733,10.158805607519563,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.4,1.92,,,72.0,9.92,49.1,9.44,40.8,0.00496,-0.14730000000000001,45.5,1.9442559950826837,9.92012979253719,1.0685327923387081e-10,0.25463582542435015,19461.759373643188,9.477557092932004,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385M-72-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.7,1.88,,,72.0,9.92,49.1,9.44,40.8,0.005456,-0.160066,45.2,1.9461419734887198,9.920102680900829,1.0950606160001007e-10,0.25420669887475106,24558.97262286129,0.8294965923887901,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,364.4,1.329,,,18.0,13.31,36.78,12.55,30.68,0.00618915,-0.09735666,46.4,1.3065570360991108,13.323595888092441,7.785718371056816e-12,0.15854503957150173,155.2112276380948,-1.828920144414521,-0.3077,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,355.4,1.85,,,22.0,11.43,44.69,10.68,36.05,0.0045802296,-0.13460940829999998,46.64,1.6883597511010915,11.451681397189205,3.576868489353779e-11,0.3311513243744388,174.57637324391595,-1.118450636448365,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,356.0,1.85,,,22.0,10.84,45.14,10.26,37.53,0.0051532276,-0.1360691132,46.62,1.7218019631342323,10.845379189817626,4.420633074790775e-11,0.22621498260906672,455.8624129107324,0.8029980116216978,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,354.9,1.85,,,22.0,11.43,44.69,10.68,36.05,0.0044702729999999994,-0.1348404556,46.58,1.6991615654092784,11.451198022481448,4.233704969838522e-11,0.3289877961558008,177.39063040015665,0.07402156443982688,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,350.1,1.95,,,24.0,10.42,47.9,9.71,39.65,0.0039091672,-0.146253549,46.46,1.961371859337785,10.433354131439858,2.520491462592172e-10,0.24094631708376468,188.0062914829318,15.028211947810217,-0.435211,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-72H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,349.2,1.95,,,24.0,10.42,47.9,9.71,39.65,0.0051476884,-0.153566442,46.7,1.9985109791270814,10.432360146977297,3.971914587805952e-10,0.23282193329344195,196.27636480983472,13.460481760072197,-0.44106,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM385N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,385.0,350.9,1.95,,,24.0,10.42,47.9,9.71,39.65,0.003912189,-0.149309569,45.89,1.9671256443146554,10.433197378531302,2.707524412766701e-10,0.23968378849056476,189.24252126754732,13.311067760304342,-0.4371,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-66H,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,362.1,1.77,,,22.0,10.93,44.29,10.39,37.54,0.0034862328,-0.139212328,45.2,1.7050861587142006,10.932104371178513,5.693632666728096e-11,0.14057078172010337,730.1177285692117,-1.236492262442793,-0.38107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-66H-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,362.0,1.77,,,22.0,10.93,44.29,10.39,37.54,0.0035774983000000002,-0.1288839,45.5,1.6928043043277268,10.932281577483163,4.714046272794135e-11,0.14318926929194745,685.9546844559912,5.094713117963523,-0.37646,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.8,1.85,,,22.0,11.39,43.75,10.69,36.49,0.0038138276,-0.1311760625,46.84,1.6673434683736188,11.40177937885822,4.4932405554427666e-11,0.19760271416067837,191.07076577698106,1.294194308705404,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.8,1.85,,,22.0,11.32,44.47,10.5,37.15,0.005335568800000001,-0.1332690301,46.72,1.7120927562163124,11.33906911237867,5.741774655122586e-11,0.19282846973442172,114.46879387767699,3.2853852335052136,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.0,1.87,,,22.0,11.15,43.92,10.57,36.9,0.00395602,-0.13295682000000003,46.62,1.6759210377330545,11.15412420973695,4.5967038484342515e-11,0.17369149012736837,469.58333484624865,0.6135077864137453,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.8,1.85,,,22.0,11.39,43.75,10.69,36.49,0.0038138276,-0.1311760625,46.84,1.6673434683736188,11.40177937885822,4.4932405554427666e-11,0.19760271416067837,191.07076577698106,1.294194308705404,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.1,1.92,,,72.0,10.12,49.3,9.49,41.1,0.0045165560000000006,-0.15250955,45.4,1.9407517865645665,10.129641736381219,9.22347233176011e-11,0.2386225003057195,250.45901118674828,4.856933998160187,-0.39107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.6,1.95,,,24.0,10.12,49.3,9.49,41.1,0.005535134,-0.15285958,45.6,1.961663933463477,10.129176776236378,1.2098437118580715e-10,0.23384407076432828,257.8794566006725,6.797916826848026,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.3,1.95,,,24.0,10.46,48.6,9.84,39.64,0.005841073200000001,-0.15888798,45.6,1.922224682324294,10.469135609918377,1.0816538393650983e-10,0.3241564829168704,371.14949327408397,0.0368037540320058,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,361.7,2.01,,,24.0,10.46,48.6,9.84,39.64,0.005104480000000001,-0.14337,46.3,1.8060678837040858,10.472544498640781,2.1209264655525887e-11,0.3494975074468542,291.42208647960285,-2.639668916815252,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.5,1.956,,,144.0,10.12,49.3,9.49,41.1,0.0063756,-0.16762000000000002,45.1,1.985446985842161,10.128662687136856,1.6357999183761133e-10,0.22843315670074918,266.8621878513824,-0.37830176006668054,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,390.0,358.6,1.98,,,24.0,10.41,48.14,9.84,39.62,0.0058296,-0.1506782,45.3,1.9317178717518053,10.414204708339868,1.5548932883341316e-10,0.2758585931874659,682.969682163489,7.6481178887148245,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.7,1.95,,,24.0,10.46,48.6,9.84,39.64,0.005112011200000001,-0.15028578,45.5,1.8732659797104423,10.470520709081725,5.5787378234652774e-11,0.33476397986228523,332.83225534556146,0.3938569473208864,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,390.0,358.5,1.98,,,24.0,10.17,48.14,9.84,39.62,0.0048816,-0.1550108,45.2,1.9374211444107903,10.170138624949859,1.6446093440888626e-10,0.18924299047258689,13883.53563952198,5.367221080160756,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM390M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,361.8,1.956,,,144.0,10.12,49.3,9.49,41.1,0.0064768000000000004,-0.158746,45.1,1.943822097373734,10.12957270947243,9.601815955193992e-11,0.2379197123409153,251.52205391981246,0.7961331724091648,-0.372,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.7,1.95,,,24.0,10.46,48.6,9.84,39.64,0.004703339,-0.14738922000000002,45.3,1.896944763949951,10.469841514253256,7.717198543478658e-11,0.3296205548044008,350.3354311505849,5.140237350848344,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,358.7,1.92,,,72.0,10.12,49.3,9.49,41.1,0.006780400000000001,-0.153323,45.6,2.0131925410095777,10.128082540826313,2.304907650155075e-10,0.22215194056274556,278.152355619297,11.999912684560698,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.1,1.92,,,72.0,10.12,49.3,9.49,41.1,0.00506,-0.1479,45.5,1.9704552365677,10.128984929306508,1.353695120985331e-10,0.23184104971757483,261.1296565640104,11.467620285673906,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,369.3,1.329,,,18.0,13.39,36.98,12.63,30.88,0.006226350000000001,-0.09788605999999998,46.4,1.314136663464885,13.40315002644215,7.915167543559687e-12,0.1554698108540253,158.30696485150528,-1.7456175006500796,-0.3077,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.1,1.85,,,22.0,11.53,44.88,10.8,36.11,0.0046203016000000005,-0.1351817016,46.64,1.6911608959501985,11.54913985734847,3.3800433363013595e-11,0.3396534565059279,204.60990651713018,-1.648586198648089,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,360.7,1.85,,,22.0,10.92,45.33,10.34,37.72,0.0051912588,-0.1366418454,46.62,1.7294681901480842,10.92508230127364,4.4834378404516157e-11,0.22196804288989835,476.9278646281107,0.8566497450138849,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,359.7,1.85,,,22.0,11.53,44.88,10.8,36.11,0.004509383,-0.1354137312,46.58,1.7019636750311669,11.548660882139432,4.001440403029937e-11,0.3375192614787513,208.543043653898,-0.46056801488767884,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,354.8,1.95,,,24.0,10.48,48.05,9.81,39.76,0.0039316768000000005,-0.1467115455,46.46,1.9623801346386924,10.490477045493662,2.390986969228501e-10,0.24278533366598434,242.85381337948297,14.469061729626985,-0.435211,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-72H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,353.9,1.95,,,24.0,10.48,48.05,9.81,39.76,0.005177329600000001,-0.154047339,46.7,1.9994585802266756,10.489574958786072,3.7687358592948363e-10,0.2347670154837666,256.95761209951985,12.91045109296211,-0.44106,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM390N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,390.0,355.6,1.95,,,24.0,10.48,48.05,9.81,39.76,0.003934716,-0.1497771355,45.89,1.9681099569126135,10.4903349373897,2.568035535426132e-10,0.2415424479395249,244.93278707823566,12.758995279389081,-0.4371,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.6,1.85,,,22.0,11.48,43.93,10.8,36.58,0.0038439632000000002,-0.1317157583,46.84,1.6707352959111403,11.49043017765277,4.301346864766893e-11,0.20357297226742269,224.0630820182562,0.8645772227800118,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,365.6,1.85,,,22.0,11.42,44.59,10.6,37.27,0.0053827028,-0.1336286497,46.72,1.716587869434228,11.438592421795065,5.7859527702458726e-11,0.18959934367812956,116.4573687989335,3.2735400212500085,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.8,1.87,,,22.0,11.25,44.0,10.69,36.95,0.0039915,-0.133199,46.62,1.6765676657350204,11.252744853110363,4.479343474428313e-11,0.17465674512033252,715.8446645614246,0.32209340988538926,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.6,1.85,,,22.0,11.48,43.93,10.8,36.58,0.0038439632000000002,-0.1317157583,46.84,1.6707352959111403,11.49043017765277,4.301346864766893e-11,0.20357297226742269,224.0630820182562,0.8645772227800118,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.9,1.92,,,72.0,10.23,49.5,9.55,41.4,0.004565649000000001,-0.15312825,45.4,1.956730831485518,10.241710878740719,1.0299881566114763e-10,0.21995744224757194,192.1431111727716,5.719995339048436,-0.39107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.4,1.95,,,24.0,10.54,48.8,9.9,39.9,0.0057648529999999995,-0.15130928,45.6,1.919503308245349,10.550833111519177,9.451511606838152e-11,0.3146707596362538,306.1567246519517,4.336106784035099,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.1,1.95,,,24.0,10.54,48.8,9.9,39.9,0.0058857468,-0.15954184,45.6,1.9342938158503298,10.550419889535405,1.1484142656180927e-10,0.31148977014629176,315.08034006826216,0.46569715834953734,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,366.5,2.01,,,24.0,10.54,48.8,9.9,39.9,0.00514352,-0.14395999999999998,46.3,1.8171887686541994,10.553878654612932,2.2524680738778558e-11,0.3369381682767236,255.88418933174296,-2.2175198277501535,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,366.3,1.95,,,24.0,10.54,48.8,9.9,39.9,0.005319959599999999,-0.14606815999999997,45.4,1.8649852930674464,10.552414865007878,4.488592737727618e-11,0.32647799447835024,277.1740269354862,1.8604727931291174,-0.37035,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,395.0,363.3,1.98,,,24.0,10.5,48.26,9.92,39.83,0.00588,-0.1510538,45.3,1.940027359317289,10.504591710069803,1.6388573890944346e-10,0.26103572850274015,596.9182305077843,8.033674126973494,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,365.4,1.95,,,24.0,10.54,48.8,9.9,39.9,0.005151108799999999,-0.15090424,45.5,1.8849170512387385,10.551825813780072,5.922524564051157e-11,0.32214616168386634,287.1194025481844,0.823949701046093,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,395.0,363.2,1.98,,,24.0,10.23,48.26,9.92,39.83,0.0049104000000000005,-0.15539719999999999,45.2,1.9469132028668443,10.230140519534729,1.755636201467579e-10,0.1614910293807303,11756.770713515172,5.873002784959929,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL-TV-Q,Jinko Solar Co Ltd,Mono-c-Si,1,395.0,362.6,1.98,,,24.0,10.23,48.26,9.92,39.83,0.0044555742,-0.14919579,45.2,1.9525718494186723,10.230138899333218,1.8863947553420205e-10,0.1594886391278969,11746.432450286307,10.994721487866553,-0.42063,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,363.0,1.95,,,24.0,10.54,48.8,9.9,39.9,0.0051254965999999996,-0.14899616,45.3,1.9553035168463662,10.549844443543632,1.5068575929646333e-10,0.30698727795682895,328.67739957555114,10.099788485789622,-0.41565,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.5,1.95,,,24.0,10.54,48.8,9.9,39.9,0.0047393109999999995,-0.14799575999999998,45.3,1.9087483404157357,10.551137824414184,8.187748481030799e-11,0.3169897439491043,299.9752818692235,5.584857598680271,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,363.4,1.92,,,72.0,10.23,49.5,9.55,41.4,0.0068541,-0.153945,45.6,2.0298938453260744,10.240007086112836,2.567970213870009e-10,0.2033718614132238,207.90210198849553,12.90301388075418,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,363.9,1.92,,,72.0,10.23,49.5,9.55,41.4,0.005115000000000001,-0.1485,45.5,1.9866806028621848,10.24099543976985,1.5092920742344826e-10,0.21313996747284036,198.30238468380435,12.371261402306065,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,374.2,1.329,,,18.0,13.47,37.18,12.71,31.08,0.0062635500000000005,-0.09841546,46.4,1.3217155667608385,13.48271475857431,8.045389249348492e-12,0.15243390967819845,161.4883016675032,-1.6633357557344735,-0.3077,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.9,1.85,,,22.0,11.63,45.07,10.92,36.18,0.004660373600000001,-0.1357539949,46.64,1.6942701695918547,11.646357364367136,3.2097392697137504e-11,0.3468838863508298,246.63262279803237,-2.136466848184229,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,365.5,1.85,,,22.0,11.0,45.52,10.42,37.91,0.00522929,-0.1372145776,46.62,1.7371357504641205,11.004793510436928,4.5466981872542514e-11,0.21778622433127337,499.7691283753081,0.9099798740117386,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,364.5,1.85,,,22.0,11.63,45.07,10.92,36.18,0.004548493000000001,-0.1359870068,46.58,1.7050741160034173,11.645883336318981,3.800268229558557e-11,0.3447778294119736,252.4511328352747,-0.9529131849960023,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,359.5,1.95,,,24.0,10.54,48.2,9.91,39.86,0.003954186399999999,-0.14716954200000001,46.46,1.963230237976032,10.547558113933563,2.263575099606322e-10,0.2457205774259833,342.66420450806396,13.89456995546692,-0.435211,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-72H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,358.6,1.95,,,24.0,10.54,48.2,9.91,39.86,0.0052069708,-0.154528236,46.7,2.0002397783016086,10.54674318883456,3.5686448188139743e-10,0.23780914770918377,371.70970739983505,12.34496957056741,-0.44106,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM395N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,395.0,360.3,1.95,,,24.0,10.54,48.2,9.91,39.86,0.003957243,-0.150244702,45.89,1.9689348898607482,10.54742984630607,2.4308219314257256e-10,0.24449737557147722,346.84466678857586,12.191781041826113,-0.4371,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.3,1.85,,,22.0,11.57,44.12,10.91,36.67,0.0038740988000000006,-0.1322854372,46.84,1.6743533962507617,11.578977948349692,4.108260082045851e-11,0.2103335023039663,271.05955206800417,0.41878483662011096,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,370.4,1.85,,,22.0,11.52,44.71,10.7,37.39,0.0054298368,-0.1339882693,46.72,1.7210906455593982,11.53812360556525,5.830671495680428e-11,0.18642789883975575,118.50011852265108,3.262661589392866,-0.363724,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-6RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.5,1.87,,,22.0,11.37,44.05,10.81,37.01,0.004034075999999999,-0.1333503625,46.62,1.6784346855740073,11.372427916507966,4.5271505593234625e-11,0.17116672706604677,801.5785385397858,0.32002677168722515,-0.373883,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.3,1.85,,,22.0,11.57,44.12,10.91,36.67,0.0038740988000000006,-0.1322854372,46.84,1.6743533962507617,11.578977948349692,4.108260082045851e-11,0.2103335023039663,271.05955206800417,0.41878483662011096,-0.373958,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72BL,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.6,1.92,,,72.0,10.36,49.8,9.6,41.7,0.004623668,-0.1540563,45.4,1.9777377159617031,10.37554891104552,1.1621533508977173e-10,0.2109668892811582,140.56399184195948,6.67378135680121,-0.39107,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.1,1.95,,,24.0,10.61,49.1,9.96,40.16,0.0058031395,-0.15223946000000002,45.6,1.9322620457479367,10.621387367036856,9.628068324142546e-11,0.31275345357471324,291.40311890306737,4.43849918359356,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,368.8,1.95,,,24.0,10.61,49.1,9.96,40.16,0.0059248362,-0.16052263000000003,45.6,1.9471668057397835,10.620967584769923,1.1699951179732e-10,0.3095659212235236,299.47291456891327,0.5651162443387442,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,371.2,2.01,,,24.0,10.61,49.1,9.96,40.16,0.0051776800000000005,-0.144845,46.3,1.8292309575636143,10.624477968057748,2.294957889788521e-11,0.33505073050356143,245.53779025985892,-2.1195762422849267,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,371.1,1.95,,,24.0,10.61,49.1,9.96,40.16,0.0053552914,-0.14696612,45.4,1.8773602480395188,10.622992806692524,4.5727752376223044e-11,0.32457694937933457,265.0513917567995,1.9612492573921712,-0.37035,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,400.0,368.1,1.98,,,24.0,10.59,48.35,10.0,40.01,0.0059304,-0.1513355,45.3,1.946986687415018,10.594921562699177,1.7234922827519774e-10,0.24690492811940398,531.2791094554713,8.401598111920096,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,370.2,1.95,,,24.0,10.61,49.1,9.96,40.16,0.0051853192,-0.15183193,45.5,1.8974358268860987,10.622394891549897,6.033737253955905e-11,0.32023839231294093,274.1233662218746,0.9237373276548764,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,400.0,368.0,1.98,,,24.0,10.32,48.35,10.0,40.01,0.0049536,-0.15568700000000002,45.2,1.9522705541656826,10.320135244202186,1.810339003786089e-10,0.15386306373838413,11740.758006824357,6.060068859544536,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM400M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,367.7,1.95,,,24.0,10.61,49.1,9.96,40.16,0.0051595369,-0.14991212,45.3,1.968305358897334,10.62038385616566,1.534748692721577e-10,0.3050612918707087,311.7050597560713,10.206237559839538,-0.41565,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.2,1.95,,,24.0,10.61,49.1,9.96,40.16,0.0047707865,-0.14890557000000001,45.3,1.921427243347924,10.621696802487884,8.340368019989743e-11,0.3150765159019125,285.8013503372788,5.688079958535846,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72L,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,368.2,1.92,,,72.0,10.36,49.8,9.6,41.7,0.006941200000000001,-0.154878,45.6,2.0518068962011933,10.373526028698205,2.889300572839993e-10,0.19422102896822113,148.75984489387596,13.897533852284157,-0.406,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400M-72L-V,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,368.6,1.92,,,72.0,10.36,49.8,9.6,41.7,0.005180000000000001,-0.1494,45.5,2.0080076484311142,10.374703394687687,1.699900656172836e-10,0.20409505131961353,143.80521112279607,13.369081689242817,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,379.1,1.329,,,18.0,13.55,37.38,12.79,31.28,0.006300750000000001,-0.09894486,46.4,1.3292937601704058,13.562289876219273,8.176376172937925e-12,0.14943658576362823,164.75883938118707,-1.5820567761406474,-0.3077,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-6RL3,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.7,1.85,,,22.0,11.73,45.25,11.04,36.24,0.0047004456,-0.1362961675,46.64,1.697007681717715,11.743383846690321,3.048499570117701e-11,0.3540707223706875,310.3180878986881,-2.620119133547313,-0.373575,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-6RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,370.3,1.85,,,22.0,11.08,45.71,10.5,38.1,0.0052673212,-0.1377873098,46.62,1.7448048000120067,11.08451266724448,4.610426721201121e-11,0.21366795996832227,524.6212357223566,0.9630778582747033,-0.366362,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-6RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,369.2,1.85,,,22.0,11.73,45.25,11.04,36.24,0.004587603,-0.13653011,46.58,1.7078165871765205,11.74291426184561,3.6101188457727285e-11,0.3519915222362616,319.713253711683,-1.4402359661688129,-0.380153,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,364.2,1.95,,,24.0,10.6,48.35,10.01,39.96,0.003976696,-0.14762753850000002,46.46,1.9641946928557918,10.604545420500667,2.1458815006573996e-10,0.24855182153644467,579.6272531690591,13.335889662927949,-0.435211,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-72H-MBB-B,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,363.4,1.95,,,24.0,10.6,48.35,10.01,39.96,0.005236612,-0.15500913300000002,46.7,2.0011373549531015,10.603815548306327,3.3836800227463556e-10,0.2407444435029181,668.813880351928,11.794843069062976,-0.44106,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM400N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,400.0,365.1,1.95,,,24.0,10.6,48.35,10.01,39.96,0.0039797700000000005,-0.15071226850000002,45.89,1.9698752719340262,10.60443058455816,2.3040928710444157e-10,0.24734762697926346,591.7695938561714,11.640194290711564,-0.4371,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,373.9,1.95,,,24.0,10.69,49.4,10.02,40.42,0.0058468955,-0.15316964,45.6,1.945956251866267,10.702783479685083,9.924702978110578e-11,0.3104971332031474,259.6487424400285,4.6367702571936595,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,373.6,1.95,,,24.0,10.69,49.4,10.02,40.42,0.0059695098,-0.16150342,45.6,1.9609975550957,10.702347946073472,1.2062919886565588e-10,0.3072977425156996,266.03719398889115,0.7575696577319105,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,376.0,2.01,,,24.0,10.69,49.4,10.02,40.42,0.00521672,-0.14573,46.3,1.842122916956997,10.705981732892655,2.3664942833927526e-11,0.3328469768219982,222.63757203163158,-1.9298250969109731,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,375.9,1.95,,,24.0,10.69,49.4,10.02,40.42,0.005395670599999999,-0.14786407999999998,45.4,1.890623300973311,10.704445772391585,4.7143456546588777e-11,0.32234928171944455,238.54133835935318,2.156471588464057,-0.37035,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HL-BDVP,Jinko Solar Co Ltd,Mono-c-Si,1,405.0,372.8,1.98,,,24.0,10.68,48.45,10.08,40.19,0.0059808000000000005,-0.15164850000000002,45.3,1.954123087378164,10.685204395949413,1.806685530457879e-10,0.23401054744733066,480.2157433482827,8.743130483741663,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,374.9,1.95,,,24.0,10.69,49.4,10.02,40.42,0.005224416799999999,-0.15275962,45.5,1.9108637002386828,10.703826686581866,6.220829298965728e-11,0.31799867039690344,245.85831459709067,1.1170617138325833,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,405.0,372.7,1.98,,,24.0,10.42,48.45,10.08,40.19,0.0050016,-0.156009,45.2,1.956959411637619,10.420136206236922,1.843007812463118e-10,0.15309128768395755,11711.75370387488,6.130470878749371,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM405M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,372.5,1.95,,,24.0,10.69,49.4,10.02,40.42,0.0051984401,-0.15082807999999998,45.3,1.982266636302532,10.701743856411738,1.5815438195885836e-10,0.30278972732924564,275.6183405275966,10.412519519151207,-0.41565,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,374.0,1.95,,,24.0,10.69,49.4,10.02,40.42,0.004806758499999999,-0.14981538,45.3,1.9350296056776615,10.703104222442658,8.596825192625136e-11,0.3128272650675462,255.19435167350863,5.888167866382484,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,371.5,2.09,,,26.0,10.2,51.07,9.44,42.91,0.004760952,-0.160941998,45.2,2.1015353344367855,10.212944550197651,2.755081453698729e-10,0.18565723871338696,146.29352622535367,12.349714120644697,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,371.3,2.09,,,26.0,10.01,51.55,9.37,43.23,0.0029412382999999998,-0.16435170999999998,45.1,2.0836565166543606,10.018542656042019,1.7664456894642304e-10,0.20975606138634184,245.7851796743305,7.470851469795392,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,373.1,2.14,,,26.0,10.15,51.55,9.44,42.9,0.004679150000000001,-0.15568099999999999,45.8,2.0232906682374825,10.165391266339002,8.491302354116058e-11,0.2594581065685851,171.10351822474263,6.701106353732208,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,373.4,2.09,,,26.0,10.2,51.07,9.44,42.91,0.005582154,-0.16434326,45.4,2.059717418237679,10.214022319570127,1.6805414013009216e-10,0.1952820900703098,142.05048941241705,5.621108904324445,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,378.9,1.95,,,18.0,13.3,38.1,12.85,31.52,0.006131300000000001,-0.096393,46.96,1.3414360602482462,13.300002489858125,6.149588234060782e-12,0.18720370082507806,999995.6139716908,0.7230148648417991,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,382.5,2.0,,,18.0,13.3,38.1,12.85,31.52,0.005985,-0.096774,45.32,1.3032392930380183,13.300873914656666,2.6725507699674578e-12,0.19383553634435963,2949.9589695697937,-6.322423257496182,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,369.0,1.95,,,24.0,10.66,48.5,10.11,40.06,0.0039992056,-0.14808553500000002,46.46,1.965267463715651,10.661442598592624,2.0369569740689223e-10,0.2512843415766771,1856.8517333028474,12.792224326553095,-0.435211,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM405N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,405.0,369.8,1.95,,,24.0,10.66,48.5,10.11,40.06,0.004002297,-0.151179835,45.89,1.9709262754017518,10.661340652025405,2.186858137077846e-10,0.2500982412937719,1988.6207969876764,11.103590068075555,-0.4371,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,378.6,1.95,,,24.0,10.76,49.6,10.08,40.68,0.005885182,-0.15378976000000003,45.6,1.9569499464243751,10.773038676428824,1.0392177736109516e-10,0.2985322534554834,246.35991017069418,4.973666569176958,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,378.4,1.95,,,24.0,10.76,49.6,10.08,40.68,0.0060085992,-0.16215728000000001,45.6,1.9721299337660552,10.772604827739327,1.263583385267839e-10,0.29531645350456875,252.09429537665585,1.0849151544913647,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,380.8,2.01,,,24.0,10.76,49.6,10.08,40.68,0.00525088,-0.14632,46.3,1.852413053288051,10.7762194964061,2.4794512188424075e-11,0.3209423920850054,212.91290932496733,-1.607817569500224,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,380.6,1.95,,,24.0,10.76,49.6,10.08,40.68,0.0054310024,-0.14846272,45.4,1.9012350166791614,10.774691588131269,4.937575861254279e-11,0.3104178900253624,227.34754885875,2.487824536550345,-0.37035,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,379.7,1.95,,,24.0,10.76,49.6,10.08,40.68,0.0052586272,-0.15337808000000003,45.5,1.9216263188231661,10.774075516606874,6.515837714610634e-11,0.30605259649959426,233.9612871101141,1.4451566035219692,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,410.0,377.5,1.98,,,24.0,10.51,48.56,10.16,40.38,0.0050448,-0.1563632,45.2,1.9629923686606718,10.510131131354214,1.8965812574618525e-10,0.14595738300552538,11698.305855000046,6.301989789806185,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM410M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,377.2,1.95,,,24.0,10.76,49.6,10.08,40.68,0.0052324803999999996,-0.15143872,45.3,1.9934777996348534,10.77200651369313,1.6550581976977237e-10,0.2908100688282213,260.6182419028729,10.762314665433324,-0.41565,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,378.7,1.95,,,24.0,10.76,49.6,10.08,40.68,0.004838233999999999,-0.15042192000000001,45.3,1.9459311151369245,10.77335799857196,9.000226069169497e-11,0.30087253056105145,242.35580670890192,6.2272274495879865,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,376.3,2.09,,,26.0,10.27,51.16,9.53,43.03,0.0047936252,-0.16122562399999996,45.2,2.103360406958956,10.281550580735018,2.7227536133125664e-10,0.18005290842102425,160.09094895863265,12.170829497925553,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,376.0,2.09,,,26.0,10.11,51.58,9.47,43.3,0.0029706212999999998,-0.16444735600000002,45.1,2.085308446673757,10.118110684993834,1.794670198887563e-10,0.2024600763300506,252.3672718888618,7.5194402993143745,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,377.8,2.14,,,26.0,10.2,51.58,9.53,43.03,0.0047022,-0.1557716,45.8,2.022303395403431,10.212075963634597,8.346702083666745e-11,0.24637299074029026,208.0997114932044,6.49423229529956,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,378.2,2.09,,,26.0,10.27,51.16,9.53,43.03,0.0056204628999999996,-0.16463287999999998,45.4,2.06152428778014,10.282562400434896,1.660443857584061e-10,0.18959228203297573,154.995280310628,5.451102848983413,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,383.7,1.95,,,18.0,13.37,38.32,12.92,31.74,0.006163569999999999,-0.0969496,46.96,1.35050609235687,13.370002398133941,6.356534381648817e-12,0.15476967831093116,862875.2415162812,0.9534883918722725,-0.308,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM410N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,387.3,2.0,,,18.0,13.37,38.32,12.92,31.74,0.006016499999999999,-0.0973328,45.32,1.3113018618727343,13.370002545620105,2.721448617536444e-12,0.16506112888528285,866931.207253716,-6.225552316354736,-0.285,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM410N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,373.7,1.95,,,24.0,10.72,48.65,10.21,40.16,0.0040217152,-0.1485435315,46.46,1.9709754018342154,10.720004232830522,2.0436660386617915e-10,0.2530661249533631,641002.9153265673,12.762642561657906,-0.435211,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM410N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,410.0,374.5,1.95,,,24.0,10.72,48.65,10.21,40.16,0.004024824000000001,-0.1516474015,45.89,1.9768980551255908,10.72000421622541,2.2005217653515336e-10,0.2518445530716614,640427.0685489472,11.101304855863745,-0.4371,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,379.4,2.05,,,20.0,13.43,40.62,12.5,33.2,0.006087953300000001,-0.12096514139999999,47.11,1.6062955680552922,13.454171163800556,1.3639815079768177e-10,0.20598707229330607,114.45069327456133,9.914168912469039,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,379.4,2.05,,,20.0,13.43,40.62,12.5,33.2,0.006087953300000001,-0.12096514139999999,47.11,1.6062955680552922,13.454171163800556,1.3639815079768177e-10,0.20598707229330607,114.45069327456133,9.914168912469039,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,383.4,1.95,,,24.0,10.82,49.9,10.14,40.93,0.005917999,-0.15471994,45.6,1.968511263882807,10.832773217270097,1.0417691861443806e-10,0.298251630731352,252.64447362989435,4.945989631371864,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HBL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,383.1,1.95,,,24.0,10.82,49.9,10.14,40.93,0.0060421044000000005,-0.16313807,45.6,1.9837766404606167,10.832340922103535,1.266651516925242e-10,0.29503690575999225,258.67592585586203,1.0580751849850032,-0.39519,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,385.5,2.01,,,24.0,10.82,49.9,10.14,40.93,0.005280160000000001,-0.147205,46.3,1.8633673576256018,10.835944559341318,2.4854146017729523e-11,0.3206583014829548,217.59916763659055,-1.6343449327589714,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,385.4,1.95,,,24.0,10.82,49.9,10.14,40.93,0.0054612868,-0.14936068,45.4,1.9124732557946642,10.83442091385627,4.949589721967336e-11,0.31013533700946383,232.69429627332696,2.460539564995232,-0.37035,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,384.5,1.95,,,24.0,10.82,49.9,10.14,40.93,0.0052879504,-0.15430577,45.5,1.9329816603408057,10.83380674548971,6.531641636000499e-11,0.3057709958941602,239.62506218533866,1.4181298712473795,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HL-TV,Jinko Solar Co Ltd,Mono-c-Si,1,415.0,382.2,1.98,,,24.0,10.61,48.64,10.25,40.5,0.0050928,-0.1566208,45.2,1.9668288618984784,10.610130111627775,1.9291962146871132e-10,0.1431277366777777,11671.423216261726,6.3668950740690144,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM415M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,382.0,1.95,,,24.0,10.82,49.9,10.14,40.93,0.0052616578,-0.15235468,45.3,2.0052526063328266,10.831744610865687,1.659182847164129e-10,0.2905303460561334,267.6579507884741,10.73345508541298,-0.41565,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,383.5,1.95,,,24.0,10.82,49.9,10.14,40.93,0.004865213,-0.15133173,45.3,1.9574289548227233,10.833091469064819,9.022330408223943e-11,0.30059144001881866,248.43655329279807,6.199209934816034,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,381.0,2.09,,,26.0,10.34,51.25,9.63,43.1,0.004826298400000001,-0.16150924999999997,45.2,2.1026526515984516,10.350087745299707,2.6164148884038905e-10,0.18090100241482934,185.424629485951,11.735350935849736,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,380.8,2.09,,,26.0,10.21,51.61,9.57,43.37,0.0030000043000000002,-0.164543002,45.1,2.0869729141958446,10.217691513740462,1.823394235843193e-10,0.19531230214619244,259.2647881431611,7.569173396550984,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,382.6,2.14,,,26.0,10.28,51.61,9.61,43.2,0.0047390800000000005,-0.1558622,45.8,2.026591294737552,10.291112778295918,8.750915439565909e-11,0.22719764659985026,210.17173065905345,6.832570574184314,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,382.9,2.09,,,26.0,10.34,51.25,9.63,43.1,0.0056587718,-0.16492249999999997,45.4,2.0608612916657534,10.351021427445591,1.5945186487224512e-10,0.19032256520349994,178.55539851149902,5.035997138007797,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM415N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,388.5,1.95,,,18.0,13.44,38.53,12.99,31.95,0.00619584,-0.09748090000000001,46.96,1.3586398091647365,13.440002354315785,6.488346534184901e-12,0.15126578453161035,863533.8881511067,1.0803227597397251,-0.308,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM415N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,392.1,2.0,,,18.0,13.44,38.53,12.99,31.95,0.0060479999999999996,-0.09786620000000001,45.32,1.3191887274102239,13.440002494134392,2.7784926157393076e-12,0.16158211744363113,870712.3643747331,-6.104795680340902,-0.285,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM415N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,378.4,1.95,,,24.0,10.78,48.8,10.31,40.26,0.0040442248,-0.149001528,46.46,1.9801918109824217,10.780002443495658,2.1371259766540667e-10,0.2266209943884922,999999.5594193888,13.117942692040875,-0.435211,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM415N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,415.0,379.2,1.95,,,24.0,10.78,48.8,10.31,40.26,0.004047351,-0.15211496800000002,45.89,1.986160159307419,10.780002423975013,2.3013976081394488e-10,0.2248074522665476,999999.5585341161,11.452330383335253,-0.4371,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM420M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,385.4,2.09,,,20.0,13.49,40.7,12.61,33.31,0.006759299399999999,-0.12390992900000002,46.51,1.6054600212623429,13.50916829157436,1.2927763496724326e-10,0.2018365839852453,142.04587672183703,6.921220391668289,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,385.4,2.09,,,20.0,13.49,40.7,12.61,33.31,0.006759299399999999,-0.12390992900000002,46.51,1.6054600212623429,13.50916829157436,1.2927763496724326e-10,0.2018365839852453,142.04587672183703,6.921220391668289,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,384.2,2.05,,,20.0,13.49,40.7,12.61,33.31,0.0061151519,-0.121203379,47.11,1.6070728536765446,13.50909247900244,1.3261561794864963e-10,0.2015633988913535,142.41683007687755,9.609507718115891,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,384.2,2.05,,,20.0,13.49,40.7,12.61,33.31,0.0061151519,-0.121203379,47.11,1.6070728536765446,13.50909247900244,1.3261561794864963e-10,0.2015633988913535,142.41683007687755,9.609507718115891,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-72HBL,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,388.2,1.95,,,24.0,10.88,50.2,10.2,41.18,0.005950816,-0.15565012,45.6,1.9800726228542116,10.892508760589624,1.0443332715578355e-10,0.2979743052062279,259.17520201154343,4.9186431772545,-0.39174,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-72HBL-V,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,390.3,2.01,,,24.0,10.88,50.2,10.2,41.18,0.00530944,-0.14809,46.3,1.8743216973356072,10.895670666420742,2.4914091355351958e-11,0.3203775477562041,222.43519521434786,-1.6605528398493405,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-72HL,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,390.2,1.95,,,24.0,10.88,50.2,10.2,41.18,0.0054915712,-0.15025864,45.4,1.9237115320168936,10.894151264320653,4.961664565166225e-11,0.3098561024392866,238.2284842245876,2.4335831427679184,-0.37035,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-72HL-Q,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,389.3,1.95,,,24.0,10.88,50.2,10.2,41.18,0.0053172736,-0.15523346,45.5,1.944337041842428,10.893538990255982,6.547526472169514e-11,0.30549270191940914,245.495461112202,1.3914287646477561,-0.38013,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-72HL-V,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,386.7,1.95,,,24.0,10.88,50.2,10.2,41.18,0.0052908352,-0.15327063999999999,45.3,2.01702745668078,10.891483696879192,1.6633272828450387e-10,0.2902539071173852,274.99529504751393,10.704943298146606,-0.41565,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-72HL-V-Q,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,388.3,1.95,,,24.0,10.88,50.2,10.2,41.18,0.004892192,-0.15224153999999998,45.3,1.9689268380612202,10.892825946475748,9.044544901758904e-11,0.3003136493886096,254.75021353031218,6.1715302665375775,-0.3963,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,385.7,2.09,,,26.0,10.41,51.34,9.73,43.17,0.0048589716,-0.161792876,45.2,2.102048713928155,10.418591784703077,2.5168599952832544e-10,0.18168922810452387,220.13877334830607,11.311532435475513,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,385.5,2.09,,,26.0,10.31,51.64,9.67,43.44,0.0030293873000000002,-0.164638648,45.1,2.088649502795313,10.31728499563601,1.85262185684545e-10,0.188308298266343,266.50100121302944,7.620008946502913,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,387.3,2.14,,,26.0,10.36,51.64,9.69,43.35,0.00477596,-0.15595279999999997,45.8,2.0303786213187864,10.370270575461872,9.115670391600713e-11,0.21073763536587276,212.57250364592122,7.116603940777228,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,387.7,2.09,,,26.0,10.41,51.34,9.73,43.17,0.0056970807,-0.16521212000000002,45.4,2.060298487112269,10.419448654927447,1.5328235671605647e-10,0.19099643517850218,210.4292047796031,4.631927537179843,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,386.2,2.2,,,26.0,10.63,51.1,9.82,42.77,0.0034438011000000003,-0.16112341,45.2,2.0422098108896716,10.647486457799584,1.3923416956765018e-10,0.21024954954958994,127.81049036395505,6.1232278482941345,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,393.3,1.95,,,18.0,13.51,38.74,13.06,32.16,0.00622811,-0.09801220000000001,46.96,1.36698078862423,13.510149591542644,6.648684041784803e-12,0.1472085222353425,13294.785153397148,1.2405610442281014,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM420N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,396.9,2.0,,,18.0,13.51,38.74,13.06,32.16,0.0060795,-0.0983996,45.32,1.3270757085633367,13.51000245282171,2.8361392213074702e-12,0.15813678800398157,871012.2510150841,-5.985327685351887,-0.285,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM420N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,383.1,1.95,,,24.0,10.84,48.95,10.41,40.35,0.0040667344,-0.14945952450000002,46.46,1.9898473550858957,10.840196822258044,2.2453029382837887e-10,0.20775585039792382,11442.195564357999,13.518602164187763,-0.435211,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM420N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,420.0,384.0,1.95,,,24.0,10.84,48.95,10.41,40.35,0.004069878,-0.15258253450000003,45.89,1.9958662934962026,10.840195052040668,2.418206591541854e-10,0.20588536701909366,11442.090137258127,11.848283526312223,-0.4371,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM425M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,390.2,2.09,,,20.0,13.55,40.78,12.72,33.42,0.0067893630000000005,-0.1241534866,46.51,1.606287691066026,13.564283030422489,1.2578218752449137e-10,0.1974720624126755,187.33746644275627,6.631234148807744,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-60HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,393.1,2.09,,,20.0,13.24,40.83,12.48,34.06,0.007843376,-0.1199189349,45.64,1.599552390751252,13.248599887507721,1.0729900844008444e-10,0.15036040235716155,231.48810909270637,9.234458709002057,-0.378302,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,390.2,2.09,,,20.0,13.55,40.78,12.72,33.42,0.0067893630000000005,-0.1241534866,46.51,1.606287691066026,13.564283030422489,1.2578218752449137e-10,0.1974720624126755,187.33746644275627,6.631234148807744,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,388.9,2.05,,,20.0,13.55,40.78,12.72,33.42,0.006142350500000001,-0.1214416166,47.11,1.5773408968929754,13.56554256055482,7.88643128891023e-11,0.2023509363143964,176.40949460059832,5.066124063133803,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,388.9,2.05,,,20.0,13.55,40.78,12.72,33.42,0.006142350500000001,-0.1214416166,47.11,1.5773408968929754,13.56554256055482,7.88643128891023e-11,0.2023509363143964,176.40949460059832,5.066124063133803,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,390.5,2.09,,,26.0,10.48,51.43,9.83,43.23,0.004891644800000001,-0.16207650199999998,45.2,2.101273363372749,10.487102771228832,2.415952724146062e-10,0.18360689438661076,270.9083946542576,10.87082749954953,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,390.2,2.09,,,26.0,10.41,51.67,9.77,43.51,0.0030587703,-0.164734294,45.1,2.0903378103625156,10.416890986881663,1.8823571692006366e-10,0.18144379976426747,274.10152758973584,7.67190663990116,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,392.1,2.14,,,26.0,10.44,51.67,9.77,43.5,0.00481284,-0.1560434,45.8,2.0341650051000095,10.449446985419957,9.49373402279721e-11,0.19455238964243643,215.00265879170107,7.40018047905154,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,392.4,2.09,,,26.0,10.48,51.43,9.83,43.23,0.0057353896,-0.16550173999999998,45.4,2.059567054924533,10.487886507468723,1.4703178889644955e-10,0.19280015839630982,256.20285415468794,4.211584226003846,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,390.9,2.2,,,26.0,10.72,51.2,9.92,42.85,0.0034729584000000005,-0.16143871999999998,45.2,2.0441914817370406,10.736741817489603,1.372714022649886e-10,0.20972909626015698,134.29222664996993,5.923700129853082,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,398.1,1.95,,,18.0,13.58,38.95,13.13,32.37,0.00626038,-0.0985435,46.96,1.3744830213223012,13.580159708116302,6.6960007095978786e-12,0.1745983581853764,14846.119736011724,1.2564403315570092,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM425N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,401.8,2.0,,,18.0,13.58,38.95,13.13,32.37,0.006111,-0.09893300000000001,45.32,1.334962799218378,13.580002418041222,2.894386341232405e-12,0.15472463286835106,868955.4160874973,-5.867128524953515,-0.285,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM425N-72H-MBB,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,387.9,1.95,,,24.0,10.9,49.1,10.51,40.44,0.004089244,-0.14991752100000003,46.46,1.9992729716674962,10.900297664354433,2.351510406409704e-10,0.1876876815476092,6872.789704462731,13.891582963166185,-0.435211,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM425N-72H-MBB-V,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,388.7,1.95,,,24.0,10.9,49.1,10.51,40.44,0.004092405,-0.15305010100000002,45.89,2.0053101717366943,10.900285913476683,2.5320106442424523e-10,0.18585011425634967,7085.1925449658165,12.213653042284312,-0.4371,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM425N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,425.0,394.9,2.18,,,26.0,10.42,52.26,9.84,43.2,0.0063607848,-0.14933295,45.3,1.9928702858996103,10.427078952467285,4.212152546054996e-11,0.3007663391538016,442.7187976864373,6.130347578516412,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,394.9,2.09,,,20.0,13.61,40.86,12.83,33.52,0.006819426599999999,-0.12439704420000001,46.51,1.6069092666003328,13.619612685996714,1.2198010195308014e-10,0.194074716198846,274.77824911330964,6.313955694002127,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-60HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,397.9,2.09,,,20.0,13.32,41.01,12.56,34.24,0.007890768000000001,-0.12044760029999999,45.64,1.6070540633304766,13.32825904244467,1.087592561117458e-10,0.14740164919127888,237.72610956606178,9.29944104404377,-0.378302,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,394.9,2.09,,,20.0,13.61,40.86,12.83,33.52,0.006819426599999999,-0.12439704420000001,46.51,1.6069092666003328,13.619612685996714,1.2198010195308014e-10,0.194074716198846,274.77824911330964,6.313955694002127,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,393.6,2.05,,,20.0,13.61,40.86,12.83,33.52,0.0061695491,-0.12167985419999999,47.11,1.6085357797373718,13.619550033620179,1.2516361396730917e-10,0.1938039560187366,276.1950470465172,8.989210601296335,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,393.6,2.05,,,20.0,13.61,40.86,12.83,33.52,0.0061695491,-0.12167985419999999,47.11,1.6085357797373718,13.619550033620179,1.2516361396730917e-10,0.1938039560187366,276.1950470465172,8.989210601296335,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-72HLM-TV,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,403.4,2.18,,,24.0,11.28,48.76,10.59,40.61,0.0052339199999999995,-0.12419171999999999,46.4,1.7093912805722666,11.296034129932712,4.512269523358784e-12,0.25982547525375743,182.78705345716943,-1.0591114430455122,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,395.2,2.09,,,26.0,10.57,51.52,9.89,43.49,0.004933653200000001,-0.162360128,45.2,2.1127896981506793,10.577432420381344,2.6594257537738467e-10,0.15997391063746216,227.5065487247917,11.666629786358014,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,395.0,2.09,,,26.0,10.51,51.7,9.87,43.57,0.0030881533,-0.16482994,45.1,2.0917352389586217,10.516546976461738,1.9058285034252537e-10,0.17590120385094818,282.37794036399004,7.694060873354561,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,396.8,2.14,,,26.0,10.52,51.7,9.85,43.66,0.00484972,-0.156134,45.8,2.038204076623074,10.528591011169869,9.916563504568941e-11,0.17745894958559455,217.3048254140635,7.7105832847288065,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,397.2,2.09,,,26.0,10.57,51.52,9.89,43.49,0.0057846439,-0.16579135999999997,45.4,2.0708012592854064,10.578237413792506,1.6204502192378653e-10,0.16920601099128324,217.1200366380964,4.970264476214728,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,396.1,2.18,,,26.0,10.96,51.1,10.14,42.41,0.0028292144000000006,-0.15720915,45.4,1.9964008152875388,10.981517354873212,8.09962551928154e-11,0.25305270706953253,128.89398664144042,3.969976470463326,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,395.7,2.2,,,26.0,10.81,51.3,10.02,42.92,0.0035021157000000003,-0.16175403,45.2,2.0459449846092035,10.826071163169448,1.349532680808393e-10,0.21036632000528663,141.4994007723665,5.701086748886645,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,396.1,2.18,,,26.0,10.96,51.1,10.14,42.41,0.0028292144000000006,-0.15720915,45.4,1.9964008152875388,10.981517354873212,8.09962551928154e-11,0.25305270706953253,128.89398664144042,3.969976470463326,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,402.9,1.95,,,18.0,13.65,39.16,13.2,32.58,0.00629265,-0.09907479999999999,46.96,1.3830411001044687,13.650001970354547,6.891871029283928e-12,0.1409563173918535,976396.6012016435,1.4526948769964338,-0.308,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM430N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,406.6,2.0,,,18.0,13.65,39.16,13.2,32.58,0.0061425,-0.09946639999999998,45.32,1.3428499789769797,13.650002375628835,2.9532309567937237e-12,0.1513451953988636,869610.2510907907,-5.750181173562929,-0.285,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM430N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,396.2,2.18,,,26.0,10.82,51.72,10.1,42.58,0.0046968538,-0.15686676,45.3,2.0400913920659254,10.835692318381952,1.0334812498384985e-10,0.2924163142942505,201.62378290408932,7.3927033601367125,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,399.7,2.18,,,26.0,10.49,52.44,9.91,43.39,0.0064035156000000005,-0.1498473,45.3,2.000345503372107,10.496766762161368,4.276130005481313e-11,0.2950174684001851,457.3432844931481,6.20116946449968,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM430N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,430.0,393.2,2.18,,,26.0,10.82,51.72,10.1,42.58,0.0079058494,-0.148881192,45.2,2.1626702628968704,10.832362497394799,4.361586719081741e-10,0.2666182214238211,233.35167209996638,26.75845131990535,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,399.7,2.09,,,20.0,13.67,40.94,12.94,33.62,0.006849490200000001,-0.1246406018,46.51,1.6075874130532954,13.675090889555323,1.1839194952809715e-10,0.1907187999189124,512.1160426249897,6.004952512207512,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-60HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,402.7,2.09,,,20.0,13.4,41.19,12.64,34.42,0.007938160000000001,-0.12097626569999999,45.64,1.6145557742732437,13.407926889803184,1.1022767182120004e-10,0.14448063977650888,244.2371073074878,9.363850541533425,-0.378302,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,399.7,2.09,,,20.0,13.67,40.94,12.94,33.62,0.006849490200000001,-0.1246406018,46.51,1.6075874130532954,13.675090889555323,1.1839194952809715e-10,0.1907187999189124,512.1160426249897,6.004952512207512,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,398.4,2.05,,,20.0,13.67,40.94,12.94,33.62,0.006196747700000001,-0.12191809179999999,47.11,1.6092215946360644,13.675034587580242,1.2150010323911197e-10,0.1904491113754094,517.1104233671967,8.673685851923832,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,398.4,2.05,,,20.0,13.67,40.94,12.94,33.62,0.006196747700000001,-0.12191809179999999,47.11,1.6092215946360644,13.675034587580242,1.2150010323911197e-10,0.1904491113754094,517.1104233671967,8.673685851923832,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-72HLM-TV,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,408.2,2.18,,,24.0,11.35,48.96,10.66,40.81,0.0052664,-0.12470112,46.4,1.7167686740514805,11.365622153926548,4.569765862834068e-12,0.25572589185862366,185.7931059211386,-1.0077951689914808,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,400.0,2.09,,,26.0,10.67,51.61,9.99,43.55,0.0049803292,-0.162643754,45.2,2.1152998376405585,10.677314898557293,2.650417933029143e-10,0.16080292490907952,234.55790576894245,11.54865575936843,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-78HB,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,399.7,2.09,,,26.0,10.61,51.73,9.97,43.64,0.0031175363,-0.16492558599999999,45.1,2.0934819102208464,10.616175730009243,1.937316339877259e-10,0.16928360699097275,290.831876396449,7.75167019714591,-0.42421,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,401.6,2.14,,,26.0,10.6,51.8,9.92,43.85,0.0048866000000000005,-0.156436,45.8,2.045362348276596,10.608316703118971,1.0390079105039993e-10,0.16400622816553662,209.03307745196412,8.052994137690803,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,401.9,2.09,,,26.0,10.67,51.61,9.99,43.55,0.0058393709,-0.16608098,45.4,2.073285812285981,10.678115521841564,1.6149839652975215e-10,0.1699444881223486,223.43698592415888,4.859444877437472,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,400.9,2.18,,,26.0,11.05,51.2,10.23,42.52,0.0028524470000000006,-0.15751679999999998,45.4,2.0003023700766467,11.070988842114927,8.171456697975298e-11,0.24851880873616808,130.83774955290258,3.973002325457521,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,400.4,2.2,,,26.0,10.9,51.4,10.12,42.99,0.003531273,-0.16206934,45.2,2.0477370418425105,10.915382363438162,1.327290557277792e-10,0.21097580590797504,149.49824419825956,5.483122504331676,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,400.9,2.18,,,26.0,11.05,51.2,10.23,42.52,0.0028524470000000006,-0.15751679999999998,45.4,2.0003023700766467,11.070988842114927,8.171456697975298e-11,0.24851880873616808,130.83774955290258,3.973002325457521,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,407.7,1.95,,,18.0,13.72,39.36,13.27,32.78,0.006324920000000001,-0.0995808,46.96,1.390792650799368,13.720001933154933,7.024925115414107e-12,0.1376833474562565,977062.1435672328,1.5692822194480567,-0.308,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM435N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,411.4,2.0,,,18.0,13.72,39.36,13.27,32.78,0.006174000000000001,-0.0999744,45.32,1.3497662583774162,13.72008877353979,2.971812263020214e-12,0.17549937573231156,27123.53073884108,-5.740796277582935,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,400.9,2.18,,,26.0,10.88,51.94,10.16,42.82,0.004722899200000001,-0.15753402,45.3,2.049897059764795,10.895175687053902,1.0541484944999931e-10,0.28533410901988593,204.56636800662255,7.515132739039851,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,404.4,2.18,,,26.0,10.56,52.62,9.98,43.59,0.006446246400000001,-0.15036165,45.3,2.008063932395365,10.566449815552533,4.354303403364698e-11,0.28819083004153034,471.8422111400297,6.298689389933976,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM435N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,435.0,397.9,2.18,,,26.0,10.88,51.94,10.16,42.82,0.0079496896,-0.149514484,45.2,2.1730640262497105,10.891903537811888,4.4452187283769276e-10,0.259540947659305,237.22407874414728,26.89589954225994,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,404.4,2.09,,,20.0,13.73,41.02,13.05,33.72,0.0068795538,-0.12488415940000003,46.51,1.6083200536014084,13.730715108656643,1.1500228341577013e-10,0.18740388826217652,3598.1340941269737,5.7039154176987426,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-60HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,407.5,2.09,,,20.0,13.48,41.36,12.72,34.59,0.007985552,-0.12147556080000001,45.64,1.621624414016021,13.487608665179334,1.1163268140119393e-10,0.14171147245879281,251.06515624123205,9.422019224801781,-0.378302,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,404.4,2.09,,,20.0,13.73,41.02,13.05,33.72,0.0068795538,-0.12488415940000003,46.51,1.6083200536014084,13.730715108656643,1.1500228341577013e-10,0.18740388826217652,3598.1340941269737,5.7039154176987426,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,403.1,2.05,,,20.0,13.73,41.02,13.05,33.72,0.006223946300000001,-0.12215632940000001,47.11,1.609962045920429,13.730665120061428,1.1803929976385544e-10,0.18713522366438776,3863.013458124031,8.366332002143142,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,403.1,2.05,,,20.0,13.73,41.02,13.05,33.72,0.006223946300000001,-0.12215632940000001,47.11,1.609962045920429,13.730665120061428,1.1803929976385544e-10,0.18713522366438776,3863.013458124031,8.366332002143142,-0.402892,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-72HLM-TV,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,413.1,2.18,,,24.0,11.42,49.16,10.73,41.01,0.00529888,-0.12521052,46.4,1.724146592588341,11.43521801936058,4.6275944318319725e-12,0.25167995558367817,188.8672256335031,-0.9568358505015131,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,404.7,2.09,,,26.0,10.77,51.7,10.08,43.65,0.0050270052,-0.16292737999999998,45.2,2.120059667070264,10.777416938383995,2.7071340969191315e-10,0.15670293144232697,227.54545867990814,11.656855099409423,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,406.3,2.14,,,26.0,10.68,51.9,10.02,43.92,0.004923480000000001,-0.156738,45.8,2.046201434952224,10.68739871601727,1.0103561479956845e-10,0.16546189662271515,238.84321047815308,7.734200060129556,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,406.7,2.09,,,26.0,10.77,51.7,10.08,43.65,0.0058940979,-0.16637059999999998,45.4,2.0779459620642453,10.77822799238615,1.649856561627335e-10,0.16578862905188504,217.00841473347214,4.962816723930439,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,405.6,2.18,,,26.0,11.14,51.3,10.32,42.64,0.0028756796000000005,-0.15782445,45.4,2.004470719678342,11.160383301864572,8.271211619028706e-11,0.24293444994657687,132.76994187548593,4.004296406243199,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,405.2,2.2,,,26.0,10.99,51.5,10.22,43.06,0.0035604303000000004,-0.16238465,45.2,2.0495663294326634,11.004675753930893,1.305935856119301e-10,0.21155888311329948,158.42676158269595,5.26965674221264,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,405.6,2.18,,,26.0,11.14,51.3,10.32,42.64,0.0028756796000000005,-0.15782445,45.4,2.004470719678342,11.160383301864572,8.271211619028706e-11,0.24293444994657687,132.76994187548593,4.004296406243199,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440N-54HL4-B,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,412.6,1.95,,,18.0,13.8,39.57,13.34,32.99,0.006361800000000001,-0.1001121,46.96,1.3979151381216621,13.800004122577331,7.0233867168695236e-12,0.1657000847511965,554671.2483817196,1.5190596526810627,-0.308,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,416.3,2.0,,,18.0,13.8,39.57,13.34,32.99,0.00621,-0.1005078,45.32,1.357198754899222,13.800004308717241,3.0042969586760748e-12,0.17253508385486083,552598.8269335077,-5.7016387339588785,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,405.7,2.18,,,26.0,10.94,52.16,10.22,43.06,0.0047489446,-0.15820128,45.3,2.059701284923598,10.954670167667603,1.0750309891747458e-10,0.27833679967633074,207.56440778338617,7.6363733084443375,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,409.2,2.18,,,26.0,10.63,52.8,10.05,43.78,0.006488977200000001,-0.150876,45.3,2.01554107928868,10.636154068947551,4.4195333030710276e-11,0.2826101408552138,488.15603092463374,6.368640763263719,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM440N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,440.0,402.7,2.18,,,26.0,10.94,52.16,10.22,43.06,0.0079935298,-0.15014777599999998,45.2,2.183455834814938,10.951455428400074,4.529638310891373e-10,0.25254868306677064,241.1854689343754,27.031965248586914,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,409.2,2.09,,,20.0,13.79,41.1,13.16,33.82,0.006909617399999999,-0.12512771700000003,46.51,1.6141285428536605,13.790002409214017,1.2057909100590083e-10,0.17467713741902674,999999.918171233,6.068191845861835,-0.396671,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM445M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,409.2,2.09,,,20.0,13.79,41.1,13.16,33.82,0.006909617399999999,-0.12512771700000003,46.51,1.6141285428536605,13.790002409214017,1.2057909100590083e-10,0.17467713741902674,999999.918171233,6.068191845861835,-0.396671,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM445M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,407.9,2.05,,,20.0,13.79,41.1,13.16,33.82,0.0062511449,-0.122394567,47.11,1.6158263312918253,13.790002403767076,1.2384863477581866e-10,0.17427900509627228,999993.450230301,8.745614799778666,-0.402892,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM445M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,407.9,2.05,,,20.0,13.79,41.1,13.16,33.82,0.0062511449,-0.122394567,47.11,1.6158263312918253,13.790002403767076,1.2384863477581866e-10,0.17427900509627228,999993.450230301,8.745614799778666,-0.402892,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM445M-72HLM-TV,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,417.9,2.18,,,24.0,11.49,49.36,10.8,41.21,0.005331359999999999,-0.12571991999999999,46.4,1.731525024302687,11.504821594231192,4.685753666949658e-12,0.24768662174993847,192.01168572902185,-0.9062301049796149,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,409.5,2.09,,,26.0,10.84,52.04,10.18,43.72,0.0050596784,-0.16399885599999997,45.2,2.1241873761583525,10.846842907962674,2.4454106111770416e-10,0.18253106081558917,289.1514570710601,10.672441846498218,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,411.1,2.14,,,26.0,10.78,52.0,10.12,43.98,0.0049695799999999995,-0.15704,45.8,2.0488588029044768,10.787313913276366,1.004497418444496e-10,0.16721999338919344,246.4660839606987,7.600226635497592,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,411.5,2.09,,,26.0,10.84,52.04,10.18,43.72,0.0059324068,-0.16746471999999998,45.4,2.0820373921644406,10.847630005840308,1.4877409138525062e-10,0.19149696638342598,272.06102041732936,4.022191849091682,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,410.4,2.18,,,26.0,11.23,51.4,10.41,42.75,0.0028989122,-0.1581321,45.4,2.008388560966513,11.249873583989805,8.344935323924975e-11,0.23856096620243739,134.80405362579398,4.008864986603797,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,409.9,2.2,,,26.0,11.08,51.6,10.32,43.13,0.0035895876000000006,-0.16269996,45.2,2.0514315917237074,11.093951656027969,1.2854204271949607e-10,0.21211681315338432,168.4570155302942,5.060535461087886,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,410.4,2.18,,,26.0,11.23,51.4,10.41,42.75,0.0028989122,-0.1581321,45.4,2.008388560966513,11.249873583989805,8.344935323924975e-11,0.23856096620243739,134.80405362579398,4.008864986603797,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,421.1,2.0,,,18.0,13.87,39.77,13.41,33.19,0.0062415,-0.10101580000000002,45.32,1.3647016879941465,13.870004282810454,3.061314903572436e-12,0.1697030782107106,549589.9194551114,-5.594247122833776,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,410.5,2.18,,,26.0,10.99,52.38,10.28,43.29,0.0047706491000000005,-0.15886854000000003,45.3,2.06826104248496,11.003511557527762,1.0797888455348985e-10,0.27292873987796146,221.994160975265,7.630391455278985,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,414.0,2.18,,,26.0,10.7,52.98,10.12,43.98,0.006531708,-0.15139034999999998,45.3,2.023260769193214,10.705854563450483,4.499262213754496e-11,0.27596478355177034,504.3626709928589,6.465042638239708,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM445N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,445.0,407.4,2.18,,,26.0,10.99,52.38,10.28,43.29,0.0080300633,-0.15078106800000002,45.2,2.192529688471236,11.000413596623172,4.5500968726738215e-10,0.24717063125969507,260.8518009907021,27.02635991950894,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,413.9,2.09,,,20.0,13.85,41.18,13.27,33.91,0.0069396810000000005,-0.1253712746,46.51,1.6207226579296041,13.850002220698965,1.2785346037929424e-10,0.16031175269993767,999997.3446169273,6.532825960602651,-0.396671,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM450M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,413.9,2.09,,,20.0,13.85,41.18,13.27,33.91,0.0069396810000000005,-0.1253712746,46.51,1.6207226579296041,13.850002220698965,1.2785346037929424e-10,0.16031175269993767,999997.3446169273,6.532825960602651,-0.396671,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM450M-6TL4,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,412.6,2.05,,,20.0,13.85,41.18,13.27,33.91,0.006278343500000001,-0.12263280459999999,47.11,1.6223991231346706,13.850002215154406,1.3125472691944924e-10,0.15991088322697083,999997.34170086,9.217168086945424,-0.402892,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM450M-6TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,412.6,2.05,,,20.0,13.85,41.18,13.27,33.91,0.006278343500000001,-0.12263280459999999,47.11,1.6223991231346706,13.850002215154406,1.3125472691944924e-10,0.15991088322697083,999997.34170086,9.217168086945424,-0.402892,N,2025.7.3,6/23/2025,2.0,bootstrapping +Jinko Solar Co Ltd JKM450M-72HLM-TV,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,422.7,2.18,,,24.0,11.56,49.56,10.87,41.4,0.00536384,-0.12622932,46.4,1.7226566037227362,11.560007056687045,3.7026327591995145e-12,0.24772798510444619,405819.6018508643,-2.934028406441661,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,414.2,2.09,,,26.0,10.92,52.13,10.27,43.82,0.0050970192000000004,-0.16428248199999998,45.2,2.1268574172456423,10.926100889374094,2.4391996323661536e-10,0.17910445057814656,320.5796070593956,10.57852731105681,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-78H-TV,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,415.8,2.14,,,26.0,10.87,52.1,10.22,44.04,0.005011069999999999,-0.157342,45.8,2.0222600716084584,10.870006438122065,7.036937333822631e-11,0.17503128969133686,295524.4688914087,4.4233232816267956,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,416.3,2.09,,,26.0,10.92,52.13,10.27,43.82,0.0059761884000000005,-0.16775433999999997,45.4,2.084663300284767,10.926852721294042,1.4837684475398668e-10,0.1880017775529021,299.58601807105543,3.9328586986438494,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,415.1,2.18,,,26.0,11.32,51.5,10.5,42.86,0.0029221448,-0.15843975,45.4,2.012314708307525,11.33937231557617,8.419557199968607e-11,0.23425968371675057,136.8870768581268,4.014245594667768,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,414.7,2.2,,,26.0,11.17,51.7,10.42,43.19,0.0036187449000000004,-0.16301527,45.2,2.0530687327881854,11.18327098942138,1.2616541489550073e-10,0.21376719617637818,179.92476336203555,4.828573565762672,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,415.1,2.18,,,26.0,11.32,51.5,10.5,42.86,0.0029221448,-0.15843975,45.4,2.012314708307525,11.33937231557617,8.419557199968607e-11,0.23425968371675057,136.8870768581268,4.014245594667768,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450N-54HL4R-B,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,426.0,2.0,,,18.0,13.94,39.97,13.48,33.39,0.006273,-0.1015238,45.32,1.3722045430710452,13.940004255464569,3.1188616584419655e-12,0.16690085824453693,546733.6204693815,-5.487942571712027,-0.285,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,415.2,2.18,,,26.0,11.05,52.6,10.34,43.52,0.004796694500000001,-0.1595358,45.3,2.07780116233936,11.063088824016623,1.0973967151796266e-10,0.2672137463643052,225.59031833206845,7.722330581254,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,418.8,2.18,,,26.0,10.77,53.16,10.19,44.16,0.0065744388,-0.1519047,45.3,2.001084464402442,10.770006154071533,3.125504317719246e-11,0.27773818944397705,486067.2848976459,3.283382787620271,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM450N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,450.0,412.1,2.18,,,26.0,11.05,52.6,10.34,43.52,0.0080739035,-0.15141436,45.2,2.202641570273902,11.0600396751896,4.62148147566551e-10,0.24146821093281443,265.7679590125776,27.12957692237318,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,418.7,2.09,,,20.0,13.93,41.33,13.36,34.06,0.0069797658,-0.1258279451,46.51,1.6221898301341555,13.930004615222611,1.1995956460736328e-10,0.1782405030541921,538029.064411425,5.937897313227943,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,418.7,2.09,,,20.0,13.93,41.33,13.36,34.06,0.0069797658,-0.1258279451,46.51,1.6221898301341555,13.930004615222611,1.1995956460736328e-10,0.1782405030541921,538029.064411425,5.937897313227943,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,419.0,2.09,,,26.0,11.0,52.22,10.36,43.92,0.00513436,-0.164566108,45.2,2.107002825776465,11.000006602752622,1.8959329997357937e-10,0.18011524882590144,300080.38312908245,8.244236983430632,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,421.0,2.09,,,26.0,11.0,52.22,10.36,43.92,0.0060199699999999995,-0.16804396,45.4,2.087312398853291,11.00609451163728,1.4801404230887488e-10,0.1845589008224894,333.1108562072417,3.845980286022433,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,419.9,2.18,,,26.0,11.41,51.6,10.59,42.97,0.0029453774,-0.15874739999999998,45.4,2.016248559455679,11.4288794092544,8.495030551363051e-11,0.23002891995759342,139.02076982071782,4.020369464041991,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,419.4,2.2,,,26.0,11.26,51.8,10.52,43.25,0.0036479022000000002,-0.16333058,45.2,2.015677529379631,11.260006300375073,7.776657238154042e-11,0.2229279466940018,398427.86108921946,0.6838419508154908,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,419.9,2.18,,,26.0,11.41,51.6,10.59,42.97,0.0029453774,-0.15874739999999998,45.4,2.016248559455679,11.4288794092544,8.495030551363051e-11,0.23002891995759342,139.02076982071782,4.020369464041991,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,420.0,2.18,,,26.0,11.11,52.82,10.4,43.75,0.0048227399,-0.16020306,45.3,2.087340607160475,11.12267520015635,1.1151397766909594e-10,0.2615657380679754,229.26623575002367,7.813428849625288,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,423.6,2.18,,,26.0,10.84,53.34,10.26,44.35,0.0066171696,-0.15241905000000003,45.3,2.0248613157226543,10.840009017700746,3.9318882808808285e-11,0.268882843149194,323223.2898630552,5.167236279524927,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM455N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,455.0,416.9,2.18,,,26.0,11.11,52.82,10.4,43.75,0.008117743699999999,-0.152047652,45.2,2.212752410479526,11.119674706516943,4.693358407465836e-10,0.23583274788736397,270.8198027765361,27.231812921353207,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-60HL4,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,423.4,2.09,,,20.0,14.01,41.48,13.45,34.2,0.0070198505999999996,-0.1262846156,46.51,1.627700263571946,14.010004600738025,1.1993859586958848e-10,0.17652617905788265,537601.1223559552,5.887522929440883,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-60HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,423.4,2.09,,,20.0,14.01,41.48,13.45,34.2,0.0070198505999999996,-0.1262846156,46.51,1.627700263571946,14.010004600738025,1.1993859586958848e-10,0.17652617905788265,537601.1223559552,5.887522929440883,-0.396671,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,423.8,2.09,,,26.0,11.08,52.32,10.45,44.02,0.005171700800000001,-0.16488124799999998,45.2,2.1127337341000385,11.080006228313847,1.9480994822420828e-10,0.17717230989565486,315199.801506828,8.417767228541424,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,425.8,2.09,,,26.0,11.08,52.32,10.45,44.02,0.0060637516,-0.16836575999999998,45.4,2.0697618094893118,11.080006764795806,1.1649832322255952e-10,0.18609177535522287,304807.05984040385,1.7571071461443815,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,424.7,2.18,,,26.0,11.5,51.7,10.68,43.08,0.00296861,-0.15905505,45.4,1.9691403416442188,11.500006187355575,4.552431302365641e-11,0.23569152293899945,438072.6996749203,-1.2317786710079794,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,424.2,2.2,,,26.0,11.35,51.9,10.62,43.32,0.0036770595000000005,-0.16364589,45.2,2.0206200593083277,11.350005127164275,7.944341640894169e-11,0.22274133040869593,493101.3868089253,0.7920716665214914,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,424.7,2.18,,,26.0,11.5,51.7,10.68,43.08,0.00296861,-0.15905505,45.4,1.9691403416442188,11.500006187355575,4.552431302365641e-11,0.23569152293899945,438072.6996749203,-1.2317786710079794,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,424.7,2.18,,,26.0,11.17,53.04,10.46,43.98,0.004848785300000001,-0.16087032,45.3,2.096879278529886,11.18227053741974,1.1330160198319892e-10,0.2559835673577913,233.0245551929462,7.903686169209858,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,428.3,2.18,,,26.0,10.91,53.52,10.33,44.53,0.0066599004,-0.1529334,45.3,2.0452194882381964,10.915055917356927,4.671748167498989e-11,0.26216317124504024,565.7134159732609,6.618292822711763,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM460N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,460.0,421.6,2.18,,,26.0,11.17,53.04,10.46,43.98,0.0081615839,-0.15268094399999999,45.2,2.2228622266499705,11.179318541173622,4.765725241034695e-10,0.23026306960173942,276.01302886484416,27.3330821502505,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465M-78H,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,428.5,2.09,,,26.0,11.16,52.43,10.54,44.12,0.0052090416,-0.16522790199999998,45.2,2.1186656205895558,11.160005355254667,1.9966409599836009e-10,0.17523419464396617,365197.2391511308,8.569901714315948,-0.41903,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465M-78H-V,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,430.6,2.09,,,26.0,11.16,52.43,10.54,44.12,0.0061075332,-0.16871973999999998,45.4,2.075494881794321,11.160006511778928,1.1933058577580684e-10,0.18411129475995272,315542.91862133594,1.8952530912252583,-0.39149,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,429.4,2.18,,,26.0,11.59,51.92,10.77,43.18,0.0029918426,-0.15973188,45.4,1.9763928146478609,11.590006404440551,4.519890333664641e-11,0.24358940381870822,440829.19879568537,-1.3505674853513385,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,428.9,2.2,,,26.0,11.44,52.0,10.72,43.38,0.0037062168000000003,-0.1639612,45.2,2.0584400363091135,11.451018167783298,1.1993212372974288e-10,0.21737411270541182,225.69631879723423,4.184074571193824,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,429.4,2.18,,,26.0,11.59,51.92,10.77,43.18,0.0029918426,-0.15973188,45.4,1.9763928146478609,11.590006404440551,4.519890333664641e-11,0.24358940381870822,440829.19879568537,-1.3505674853513385,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,429.5,2.18,,,26.0,11.22,53.26,10.52,44.21,0.004870489800000001,-0.16153758,45.3,2.074859875307731,11.220008534426483,7.979831496014184e-11,0.25665167047575715,337423.10571698233,4.797527750256677,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,433.1,2.18,,,26.0,10.98,53.7,10.4,44.72,0.006702631200000001,-0.15344775000000002,45.3,2.052698617156757,10.984796748106119,4.7394345869023626e-11,0.25694663022026176,588.163892003911,6.686148153433168,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM465N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,465.0,426.3,2.18,,,26.0,11.22,53.26,10.52,44.21,0.0081981174,-0.153314236,45.2,2.23193499521474,11.22838605450067,4.786126836805522e-10,0.22513912685420506,301.22166580550487,27.326075595746655,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM470M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,470.0,434.2,2.18,,,26.0,11.68,52.14,10.86,43.28,0.0030150752,-0.16040870999999998,45.4,2.031830745543898,11.699108534326415,8.13201763195948e-11,0.24230485206243654,148.10768111232056,3.453372716967234,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM470M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,470.0,433.7,2.2,,,26.0,11.53,52.1,10.82,43.44,0.0037353741,-0.16427651,45.2,2.030237199826543,11.530006196702397,8.259400294251875e-11,0.22446344608315633,417666.08057142503,0.9797845131833847,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM470M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,470.0,434.2,2.18,,,26.0,11.68,52.14,10.86,43.28,0.0030150752,-0.16040870999999998,45.4,2.031830745543898,11.699108534326415,8.13201763195948e-11,0.24230485206243654,148.10768111232056,3.453372716967234,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM470N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,470.0,434.3,2.18,,,26.0,11.28,53.48,10.58,44.43,0.0048965352000000005,-0.16220484,45.3,2.1147158216564947,11.29088726438635,1.1522015488995724e-10,0.24647362750948215,255.36466276418435,7.9586562426012275,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM470N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,470.0,437.9,2.18,,,26.0,11.05,53.88,10.47,44.9,0.006745362000000001,-0.15396210000000002,45.3,2.0599453549819695,11.054552456578111,4.793558590250504e-11,0.25290135645052386,613.8577491083875,6.728156702440055,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM470N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,470.0,431.1,2.18,,,26.0,11.28,53.48,10.58,44.43,0.008241957599999999,-0.15394752799999997,45.2,2.241768531784975,11.288090943595245,4.844886561253567e-10,0.22080184187914664,307.83123579042865,27.39587589742592,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM475M-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,475.0,439.0,2.18,,,26.0,11.77,52.24,10.95,43.38,0.0030383078,-0.16071635999999997,45.4,1.9883199732797885,11.770006503130643,4.574710344296063e-11,0.24799440847530713,448855.01208940655,-1.3771781527253197,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM475M-7RL3-TV,Jinko Solar Co Ltd,Mono-c-Si,0,475.0,438.5,2.2,,,26.0,11.63,52.16,10.92,43.5,0.0037677711000000005,-0.16446569599999997,45.2,2.033317317287728,11.630006028285234,8.409423670133125e-11,0.2216181919050462,427569.5730201918,1.0557929120936982,-0.40608,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM475M-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,475.0,439.0,2.18,,,26.0,11.77,52.24,10.95,43.38,0.0030383078,-0.16071635999999997,45.4,1.9883199732797885,11.770006503130643,4.574710344296063e-11,0.24799440847530713,448855.01208940655,-1.3771781527253197,-0.39787,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM475N-7RL3,Jinko Solar Co Ltd,Mono-c-Si,0,475.0,439.0,2.18,,,26.0,11.34,53.7,10.64,44.65,0.0049225806,-0.16287210000000002,45.3,2.0942315920468055,11.340007193305556,8.288737198124723e-11,0.24777914066339785,390628.052335192,5.028491079443292,-0.39906,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM475N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,475.0,442.7,2.18,,,26.0,11.12,54.06,10.54,45.07,0.006788092799999999,-0.15447645000000002,45.3,2.066950220978068,11.124320803499774,4.8332166836244553e-11,0.25000559263992983,643.4132289959077,6.743538828836167,-0.35826,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM475N-7RL3-V,Jinko Solar Co Ltd,Mono-c-Si,0,475.0,435.8,2.18,,,26.0,11.34,53.7,10.64,44.65,0.0082857978,-0.15458082,45.2,2.1157706197894393,11.340006743445722,1.076110411179336e-10,0.24339351373371398,409316.0777103924,12.68511939992336,-0.43668,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM480N-7RL3-B,Jinko Solar Co Ltd,Mono-c-Si,0,480.0,447.5,2.18,,,26.0,11.19,54.24,10.61,45.24,0.0068308236,-0.1549908,45.3,2.0739567236675223,11.194093054693159,4.8730348926244587e-11,0.2471475264343683,675.6765361071666,6.7589822020201,-0.35826,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jinko Solar Co Ltd JKM495M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,495.0,463.7,2.5,,,24.0,13.18,48.82,12.39,39.96,0.0049156128,-0.12486056740000001,45.24,1.7290994609734158,13.199768118155657,7.077737393149118e-12,0.28132133578417623,187.56541146032035,1.0526609170533434,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM495M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,495.0,453.2,2.46,,,24.0,13.22,48.7,12.37,40.02,0.006239840000000001,-0.153405,46.1,1.9599642525478576,13.235624804701182,2.0998299714293433e-10,0.22502858233469994,190.3945719134685,7.637675404653179,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM495M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,495.0,454.1,2.46,,,24.0,13.18,48.82,12.39,39.96,0.0061287,-0.15915320000000002,45.3,1.9741116654542048,13.190731204822198,2.3691713889928443e-10,0.23852007810881604,292.9489372780304,5.012112146777868,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM495M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,495.0,453.2,2.46,,,24.0,13.22,48.7,12.37,40.02,0.006239840000000001,-0.153405,46.1,1.9599642525478576,13.235624804701182,2.0998299714293433e-10,0.22502858233469994,190.3945719134685,7.637675404653179,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,500.0,467.6,2.5,,,24.0,13.29,48.78,12.47,40.1,0.0060694100999999995,-0.1439044146,44.6,1.8020715263989937,13.308558066794784,2.2872773650640148e-11,0.2506244822128583,179.4798686210279,-3.870611165662579,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,500.0,464.2,2.5,,,24.0,13.13,49.12,12.37,40.42,0.00582972,-0.1318872,46.3,1.8132202148419185,13.143655024195567,2.2230519611439575e-11,0.2515863875108593,241.9131529377978,5.541531436119361,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,500.0,468.5,2.5,,,24.0,13.25,48.9,12.48,40.07,0.004941720000000001,-0.125065173,45.24,1.7313368664183677,13.267278057946585,7.06176768228716e-12,0.2761735847027245,211.78884915205487,0.982290183993658,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,500.0,467.6,2.5,,,24.0,13.29,48.78,12.47,40.1,0.0060694100999999995,-0.1439044146,44.6,1.8020715263989937,13.308558066794784,2.2872773650640148e-11,0.2506244822128583,179.4798686210279,-3.870611165662579,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,500.0,458.0,2.46,,,24.0,13.29,48.78,12.47,40.1,0.00627288,-0.15365700000000002,46.1,1.9607219215368221,13.30287596746229,2.0527694653553107e-10,0.22313341704316605,230.30838563680086,7.385102356405138,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,500.0,458.8,2.46,,,24.0,13.25,48.9,12.48,40.07,0.00616125,-0.159414,45.3,1.9765729400840515,13.25866088387132,2.363962034784316e-10,0.23362457619530955,357.4145550172142,4.94180772446738,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM500M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,500.0,458.0,2.46,,,24.0,13.29,48.78,12.47,40.1,0.00627288,-0.15365700000000002,46.1,1.9607219215368221,13.30287596746229,2.0527694653553107e-10,0.22313341704316605,230.30838563680086,7.385102356405138,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,472.4,2.5,,,24.0,13.36,48.86,12.57,40.18,0.0061013784,-0.1441404202,44.6,1.8029450892716112,13.375514320058452,2.235667590859469e-11,0.24850549309580144,213.99799679484704,-4.099394228421186,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,469.0,2.5,,,24.0,13.23,49.18,12.47,40.5,0.00587412,-0.1320483,46.3,1.8157316844034783,13.243156572839863,2.250975489997832e-11,0.24717519876922633,248.554691833235,5.5817635745133645,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,473.3,2.5,,,24.0,13.32,48.98,12.57,40.18,0.004967827200000001,-0.1252697786,45.24,1.7119843295419246,13.320006938131385,5.032397391627645e-12,0.2738122992814896,525674.6013954291,3.3568910582242775,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,472.4,2.5,,,24.0,13.36,48.86,12.57,40.18,0.0061013784,-0.1441404202,44.6,1.8029450892716112,13.375514320058452,2.235667590859469e-11,0.24850549309580144,213.99799679484704,-4.099394228421186,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,462.7,2.46,,,24.0,13.36,48.86,12.57,40.18,0.00630592,-0.153909,46.1,1.9615262903214008,13.370156641711652,2.007852717387033e-10,0.22125411216147625,291.03666620754643,7.138112082015059,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,505.0,463.5,2.46,,,24.0,13.32,48.98,12.57,40.18,0.0061938,-0.1596748,45.3,1.9790539608883269,13.326662279908701,2.3592685136491244e-10,0.22879413450109864,457.4317365925898,4.873639392420659,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,462.7,2.46,,,24.0,13.36,48.86,12.57,40.18,0.00630592,-0.153909,46.1,1.9615262903214008,13.370156641711652,2.007852717387033e-10,0.22125411216147625,291.03666620754643,7.138112082015059,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM505N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,505.0,472.1,2.583,,,24.0,13.29,49.51,12.47,40.5,0.00615327,-0.1282309,46.9,1.7399936575738204,13.313052343351131,5.714307835638946e-12,0.28783254221809274,165.93950712985193,-2.139330296543609,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,477.2,2.5,,,24.0,13.43,48.94,12.67,40.26,0.0061333467,-0.1443764258,44.6,1.8218676101131588,13.441882419508293,2.860332626636942e-11,0.24329385446447221,274.98073961991366,-2.219098118963336,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,473.8,2.5,,,24.0,13.33,49.24,12.57,40.58,0.00591852,-0.1322094,46.3,1.8182474586305568,13.342667832871493,2.2792193659741423e-11,0.24283310655566412,255.52636922912964,5.622409897104534,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,478.1,2.5,,,24.0,13.4,49.05,12.66,40.29,0.004997664000000001,-0.1254488085,45.24,1.7362661112844011,13.413414650832,7.121319146232595e-12,0.26509408513120986,264.80456315950465,0.9463270237689798,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,477.2,2.5,,,24.0,13.43,48.94,12.67,40.26,0.0061333467,-0.1443764258,44.6,1.8218676101131588,13.441882419508293,2.860332626636942e-11,0.24329385446447221,274.98073961991366,-2.219098118963336,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,467.4,2.46,,,24.0,13.43,48.94,12.67,40.26,0.00633896,-0.154161,46.1,1.9623758929523105,13.437466747272747,1.9649534127433873e-10,0.21939074658323324,394.6052933634325,6.896529237771579,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,510.0,468.3,2.46,,,24.0,13.4,49.05,12.66,40.29,0.006231,-0.159903,45.3,1.9821431289652736,13.405502390485303,2.3840795322118443e-10,0.22299223496938275,543.0542257876161,4.90750866665453,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,467.4,2.46,,,24.0,13.43,48.94,12.67,40.26,0.00633896,-0.154161,46.1,1.9623758929523105,13.437466747272747,1.9649534127433873e-10,0.21939074658323324,394.6052933634325,6.896529237771579,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM510N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,510.0,476.8,2.583,,,24.0,13.35,49.64,12.55,40.64,0.00618105,-0.1285676,46.9,1.7437615720366353,13.370574329809665,5.677682391643585e-12,0.2841775860910906,184.3934076036888,-2.2345465356942014,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,482.0,2.5,,,24.0,13.5,49.02,12.77,40.33,0.006165315,-0.14461243140000002,44.6,1.8045759108348205,13.5095399480308,2.131964838401273e-11,0.24523305858026917,347.02980751825334,-4.568883198898295,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,478.5,2.5,,,24.0,13.43,49.3,12.67,40.65,0.00596292,-0.1323705,46.3,1.8205397130720724,13.442215650187755,2.3000387647408305e-11,0.23946744038294704,263.27274470957644,5.63455662170521,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,482.9,2.5,,,24.0,13.47,49.12,12.75,40.4,0.005023771200000001,-0.1256278384,45.24,1.7383618396787017,13.481121058831375,7.1289044320637046e-12,0.25936815713589745,314.15076064716936,0.9044247751554788,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,482.0,2.5,,,24.0,13.5,49.02,12.77,40.33,0.006165315,-0.14461243140000002,44.6,1.8045759108348205,13.5095399480308,2.131964838401273e-11,0.24523305858026917,347.02980751825334,-4.568883198898295,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,472.2,2.46,,,24.0,13.5,49.02,12.77,40.33,0.006372,-0.15441300000000002,46.1,1.9630019675181536,13.504804972462534,1.917473347068352e-10,0.2184568181515256,613.7740788712711,6.631120661052732,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,515.0,473.0,2.46,,,24.0,13.47,49.12,12.75,40.4,0.0062635500000000005,-0.1601312,45.3,1.9844767500545495,13.473641433304696,2.386739015077111e-10,0.2174993786004274,804.5505824562432,4.866198826543162,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,472.2,2.46,,,24.0,13.5,49.02,12.77,40.33,0.006372,-0.15441300000000002,46.1,1.9630019675181536,13.504804972462534,1.917473347068352e-10,0.2184568181515256,613.7740788712711,6.631120661052732,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM515N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,515.0,481.6,2.583,,,24.0,13.41,49.77,12.63,40.78,0.00620883,-0.1289043,46.9,1.747540620968316,13.428152248116476,5.64237993016178e-12,0.28056573756519565,207.26835188017841,-2.327928005626795,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,486.8,2.5,,,24.0,13.57,49.1,12.87,40.41,0.006197283300000001,-0.14484843700000002,44.6,1.8244389063792736,13.576006184563886,2.7667211331448973e-11,0.23995985769621436,542.1503965915606,-2.5843524084816996,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,483.3,2.5,,,24.0,13.53,49.36,12.77,40.73,0.00600732,-0.1325316,46.3,1.8230640620176415,13.541744725938736,2.3288525088840493e-11,0.23525148533423432,271.01123934443723,5.676060471292563,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,487.7,2.5,,,24.0,13.54,49.2,12.84,40.5,0.0050498784,-0.12583244400000002,45.24,1.740444212439439,13.548927349672727,7.094107377081053e-12,0.2553957698024227,387.3555835121543,0.8134962641459016,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,486.8,2.5,,,24.0,13.57,49.1,12.87,40.41,0.006197283300000001,-0.14484843700000002,44.6,1.8244389063792736,13.576006184563886,2.7667211331448973e-11,0.23995985769621436,542.1503965915606,-2.5843524084816996,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,476.9,2.46,,,24.0,13.57,49.1,12.87,40.41,0.006405040000000001,-0.15466500000000002,46.1,1.9639392711898338,13.57216189268683,1.87842645174045e-10,0.2166178505488891,1359.6906983462186,6.4000524353337624,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,520.0,477.8,2.46,,,24.0,13.54,49.2,12.84,40.5,0.0062961,-0.16039200000000003,45.3,1.986736131764057,13.541836264894343,2.3752259366363627e-10,0.21378104002594348,1576.350202318457,4.7748129796330385,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,476.9,2.46,,,24.0,13.57,49.1,12.87,40.41,0.006405040000000001,-0.15466500000000002,46.1,1.9639392711898338,13.57216189268683,1.87842645174045e-10,0.2166178505488891,1359.6906983462186,6.4000524353337624,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM520N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,520.0,486.4,2.583,,,24.0,13.47,49.9,12.7,40.95,0.006236610000000001,-0.129241,46.9,1.7525901205181564,13.486672861118306,5.7186992481328904e-12,0.2743029965626256,221.60931750230966,-2.2596619318128814,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM525M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,491.6,2.5,,,24.0,13.64,49.18,12.97,40.48,0.006229251600000001,-0.1450844426,44.6,1.8063580189409822,13.643649982472443,2.037377026532671e-11,0.24201432527990857,904.408587006362,-5.018898065683854,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM525M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,488.1,2.5,,,24.0,13.63,49.42,12.87,40.8,0.006051720000000001,-0.13269270000000002,46.3,1.825365198459522,13.641307432088473,2.3501157523028824e-11,0.23199457558824302,279.646702363672,5.689172579362599,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM525M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,492.6,2.5,,,24.0,13.64,49.27,12.93,40.61,0.005087174400000001,-0.1260114739,45.24,1.7443093414286106,13.649380412098113,7.30507290535082e-12,0.2492488866517427,362.4312870699197,0.9967805408115338,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM525M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,491.6,2.5,,,24.0,13.64,49.18,12.97,40.48,0.006229251600000001,-0.1450844426,44.6,1.8063580189409822,13.643649982472443,2.037377026532671e-11,0.24201432527990857,904.408587006362,-5.018898065683854,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM525M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,481.7,2.46,,,24.0,13.64,49.18,12.97,40.48,0.0064380800000000005,-0.154917,46.1,1.9650790523022645,13.646375187661642,1.8447398715766152e-10,0.21556192187819367,999999.945881244,6.189012640178911,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM525M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,525.0,482.5,2.46,,,24.0,13.64,49.27,12.93,40.61,0.006342600000000001,-0.16062020000000002,45.3,1.9913708774021552,13.642286947145491,2.445761404125253e-10,0.20775143131617627,1239.088752150508,4.9616465229114795,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM525M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,481.7,2.46,,,24.0,13.64,49.18,12.97,40.48,0.0064380800000000005,-0.154917,46.1,1.9650790523022645,13.646375187661642,1.8447398715766152e-10,0.21556192187819367,999999.945881244,6.189012640178911,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM525N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,525.0,491.2,2.583,,,24.0,13.53,50.03,12.77,41.12,0.00626439,-0.1295777,46.9,1.7576398927475263,13.545246249296236,5.795635627657608e-12,0.2681100880437955,237.9293051166276,-2.1917509325398936,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,496.4,2.5,,,24.0,13.71,49.26,13.07,40.56,0.0062612199,-0.1453204482,44.6,1.8074170428272307,13.710747168693484,1.996582344164644e-11,0.23998501262917546,4403.547820209867,-5.223769225590537,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,492.9,2.5,,,24.0,13.73,49.48,12.97,40.87,0.006096120000000001,-0.1328538,46.3,1.8276707142938287,13.740876763394185,2.371573892698781e-11,0.2287866547705185,288.8028991195286,5.702774103114493,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,497.4,2.5,,,24.0,13.71,49.35,13.02,40.71,0.0051132816,-0.12621607950000002,45.24,1.7464087215765625,13.717275121015462,7.2708796698972254e-12,0.24539705791204033,462.4519202441612,0.9080822079400925,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,496.4,2.5,,,24.0,13.71,49.26,13.07,40.56,0.0062612199,-0.1453204482,44.6,1.8074170428272307,13.710747168693484,1.996582344164644e-11,0.23998501262917546,4403.547820209867,-5.223769225590537,-0.342039,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,486.4,2.46,,,24.0,13.71,49.26,13.07,40.56,0.0064711199999999995,-0.155169,46.1,1.9713718306254582,13.710002789582152,1.9276416790513763e-10,0.2034265858033308,999999.864783277,6.5253295322702565,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM530M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,530.0,487.3,2.46,,,24.0,13.71,49.35,13.02,40.71,0.00637515,-0.16088100000000002,45.3,1.993652386510429,13.710569225611694,2.4344542558150767e-10,0.2041466786576787,4916.95143740696,4.872506983372792,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,486.4,2.46,,,24.0,13.71,49.26,13.07,40.56,0.0064711199999999995,-0.155169,46.1,1.9713718306254582,13.710002789582152,1.9276416790513763e-10,0.2034265858033308,999999.864783277,6.5253295322702565,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM530N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,499.9,2.58,,,24.0,13.78,49.74,12.94,40.96,0.006201,-0.1278318,45.17,1.7271184511161384,13.802502549271768,4.193359580340999e-12,0.2593219487018542,158.80229456203796,-4.117802904322857,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM530N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,530.0,496.0,2.583,,,24.0,13.59,50.16,12.84,41.28,0.00629217,-0.12991439999999999,46.9,1.762480844748781,13.603898184658886,5.853533616507384e-12,0.2628769096338501,257.04775839814766,-2.1512312692250695,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,501.3,2.5,,,24.0,13.79,49.34,13.17,40.63,0.0062977551,-0.14555645380000004,44.6,1.8107856201373165,13.790003238571446,2.022905072680812e-11,0.23484190974620595,999999.8433900315,-5.170240054947039,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM535M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,497.7,2.5,,,24.0,13.83,49.54,13.07,40.94,0.006140520000000001,-0.13301490000000002,46.3,1.8299805121833508,13.840452656130845,2.393227001022479e-11,0.22562662819648177,298.5285505783944,5.716852570363105,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,502.2,2.5,,,24.0,13.79,49.42,13.11,40.81,0.0051431184000000005,-0.1263951094,45.24,1.748914522607703,13.796065685916432,7.325108257328766e-12,0.24064260139566687,547.0875910168666,0.9170534483494409,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,501.3,2.5,,,24.0,13.79,49.34,13.17,40.63,0.0062977551,-0.14555645380000004,44.6,1.8107856201373165,13.790003238571446,2.022905072680812e-11,0.23484190974620595,999999.8433900315,-5.170240054947039,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM535M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,495.6,2.66,,,26.0,12.92,53.04,12.31,43.46,0.008639604,-0.14082650400000002,45.7,1.958915188411389,12.920481688550902,2.2490620075154132e-11,0.2910120488352317,7805.617727540809,6.627835155904695,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,535.0,495.8,2.66,,,26.0,13.06,53.02,12.34,43.36,0.0081225364,-0.143435006,45.5,2.0320294665848424,13.068188589188004,6.034326297316685e-11,0.2835649327202513,452.2583937540145,13.350948477224309,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,495.6,2.66,,,26.0,12.92,53.04,12.31,43.46,0.008639604,-0.14082650400000002,45.7,1.958915188411389,12.920481688550902,2.2490620075154132e-11,0.2910120488352317,7805.617727540809,6.627835155904695,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,491.2,2.46,,,24.0,13.79,49.34,13.17,40.63,0.00650888,-0.15542100000000003,46.1,1.9763045232149876,13.790002701431868,1.9817952250004247e-10,0.1958558432266171,999999.8334458185,6.713213134655531,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM535M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,535.0,492.0,2.46,,,24.0,13.79,49.42,13.11,40.81,0.00641235,-0.1611092,45.3,1.9968922770609776,13.795455397330459,2.463864112015715e-10,0.19948039112600102,999999.9464167121,4.919392239799782,-0.423,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM535M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,491.2,2.46,,,24.0,13.79,49.34,13.17,40.63,0.00650888,-0.15542100000000003,46.1,1.9763045232149876,13.790002701431868,1.9817952250004247e-10,0.1958558432266171,999999.8334458185,6.713213134655531,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM535N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,504.7,2.58,,,24.0,13.83,49.79,13.02,41.1,0.0062235,-0.1279603,45.17,1.7288718653651023,13.848994947973862,4.2213510228910955e-12,0.2499672251503363,181.99821877126624,-4.103307049082521,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM535N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,535.0,500.8,2.583,,,24.0,13.65,50.29,12.9,41.48,0.00631995,-0.1302511,46.9,1.7687844983449912,13.663405119871179,6.046403147062998e-12,0.25415136063332316,258.7941112103814,-1.9260689476146946,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,506.1,2.5,,,24.0,13.85,49.42,13.27,40.7,0.006325156500000001,-0.14579245940000002,44.6,1.8163545488897064,13.850003085887778,2.113559674419304e-11,0.2228005651531359,999998.219205626,-4.865778034970434,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM540M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,502.5,2.5,,,24.0,13.89,49.73,13.13,41.13,0.00616716,-0.13352505,46.3,1.837526265840352,13.900158751692377,2.422875503427789e-11,0.2226343454237318,304.40660451219634,5.784532553206704,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,507.0,2.5,,,24.0,13.87,49.49,13.2,40.91,0.0051729552,-0.1265741393,45.24,1.7514272396676263,13.874893528434423,7.380192644428355e-12,0.23595138861251969,668.7701595219302,0.9268533807397938,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,506.1,2.5,,,24.0,13.85,49.42,13.27,40.7,0.006325156500000001,-0.14579245940000002,44.6,1.8163545488897064,13.850003085887778,2.113559674419304e-11,0.2228005651531359,999998.219205626,-4.865778034970434,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM540M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,500.4,2.66,,,26.0,13.0,53.14,12.39,43.59,0.0086931,-0.14109201400000002,45.7,2.0340426761419828,13.000003491307236,5.859529632734712e-11,0.2685412987548602,999999.8638921295,15.193010191788836,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM540M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,540.0,500.5,2.66,,,26.0,13.13,53.1,12.42,43.48,0.008166072199999999,-0.14365143,45.5,2.035330608521935,13.136938717796658,6.092185344765346e-11,0.2774200456740874,524.95655081151,13.385279891301327,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,500.4,2.66,,,26.0,13.0,53.14,12.39,43.59,0.0086931,-0.14109201400000002,45.7,2.0340426761419828,13.000003491307236,5.859529632734712e-11,0.2685412987548602,999999.8638921295,15.193010191788836,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM540M-7TL4,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,495.9,2.46,,,24.0,13.85,49.42,13.27,40.7,0.006537200000000001,-0.155673,46.1,1.9528776839126425,13.850005668864886,1.4160698755143046e-10,0.21457079910297228,524279.8041256764,3.82772519256942,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540M-7TL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,540.0,496.8,2.46,,,24.0,13.87,49.49,13.2,40.91,0.006449549999999999,-0.16133740000000002,45.3,1.9816666812065389,13.870005316514028,1.97712773568412e-10,0.1979795489560107,516556.99041358026,3.0321151690311443,-0.423,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540M-7TL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,495.9,2.46,,,24.0,13.85,49.42,13.27,40.7,0.006537200000000001,-0.155673,46.1,1.9528776839126425,13.850005668864886,1.4160698755143046e-10,0.21457079910297228,524279.8041256764,3.82772519256942,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,509.5,2.58,,,24.0,13.89,49.88,13.11,41.19,0.0062505,-0.12819160000000002,45.17,1.7302966174963135,13.905972837665914,4.133559106481946e-12,0.24798205323755035,215.6455100179549,-4.313916212920217,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM540N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,540.0,505.6,2.583,,,24.0,13.71,50.42,12.96,41.67,0.00634773,-0.1305878,46.9,1.7748768000610389,13.722944971211161,6.223329733251404e-12,0.24639180256795698,260.9531969846711,-1.7292553956265784,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,507.2,2.5,,,24.0,13.95,49.92,13.19,41.32,0.006193799999999999,-0.13403520000000002,46.3,1.8450714899865774,13.959870270783865,2.4526663771789582e-11,0.21966973763040407,310.46695240230196,5.851630821701107,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,511.8,2.5,,,24.0,13.94,49.65,13.27,41.07,0.0051990624,-0.1269833505,45.24,1.757460446438027,13.944639049653453,7.463538026455908e-12,0.23314051707597003,700.56992064139,0.977135067970117,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,510.9,2.5,,,24.0,13.94,49.52,13.36,40.8,0.0063662586,-0.1460874664,44.6,1.8205972755628583,13.9400030586671,2.1454088886994245e-11,0.2194093059175362,999997.482014284,-4.8002993784612755,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM545M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,505.2,2.66,,,26.0,13.08,53.24,12.47,43.71,0.008746596,-0.141357524,45.7,2.037461829784147,13.100176015810838,5.873461854976091e-11,0.26826014914302376,61023.99724958415,15.14506834908612,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,545.0,505.3,2.66,,,26.0,13.2,53.19,12.5,43.6,0.008209608,-0.14389490700000002,45.5,2.038823226289646,13.20573179065092,6.135315155622295e-11,0.2721634935385551,626.7776554650725,13.396995684927147,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,505.2,2.66,,,26.0,13.08,53.24,12.47,43.71,0.008746596,-0.141357524,45.7,2.037461829784147,13.100176015810838,5.873461854976091e-11,0.26826014914302376,61023.99724958415,15.14506834908612,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,514.3,2.58,,,24.0,13.95,50.07,13.17,41.38,0.006277499999999999,-0.1286799,45.17,1.737359285879273,13.965618109544728,4.184969673040567e-12,0.24498853225433825,218.82226011963706,-4.25111450199469,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM545N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,545.0,510.4,2.583,,,24.0,13.77,50.55,13.02,41.86,0.00637551,-0.1309245,46.9,1.7809668624011274,13.782491089863214,6.404015304734186e-12,0.23870610272636547,263.14621701985214,-1.5337371771778427,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM550M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,515.7,2.5,,,24.0,14.03,49.62,13.45,40.9,0.006407360700000001,-0.1463824734,44.6,1.8248382358214141,14.030003031512866,2.1775040880349903e-11,0.21606541932354786,999992.5810434539,-4.7352878524762,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM550M-72HL4-BDVP,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,512.0,2.5,,,24.0,14.01,50.11,13.25,41.51,0.006220440000000001,-0.13454535,46.3,1.8526161928953027,14.019587138828575,2.4825987965374246e-11,0.2167324223531135,316.71819301844084,5.91815442069661,-0.3479,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM550M-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,516.6,2.5,,,24.0,14.01,49.81,13.34,41.23,0.0052251696,-0.12739256170000002,45.24,1.7634938774207067,14.014389473819561,7.547334890562529e-12,0.23035928072036527,735.2438314032997,1.0271173531037439,-0.322076,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM550M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,515.7,2.5,,,24.0,14.03,49.62,13.45,40.9,0.006407360700000001,-0.1463824734,44.6,1.8248382358214141,14.030003031512866,2.1775040880349903e-11,0.21606541932354786,999992.5810434539,-4.7352878524762,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM550M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,509.9,2.66,,,26.0,13.17,53.34,12.55,43.83,0.008806779,-0.14162303400000004,45.7,2.043079351283499,13.170003427885094,6.041933369572953e-11,0.2602597358157996,999999.9678370752,15.358016781342057,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM550M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,550.0,510.1,2.66,,,26.0,13.27,53.27,12.58,43.72,0.0082531438,-0.144111331,45.5,2.042137652445278,13.274567570821986,6.19456336462087e-11,0.26616696564200587,773.2854104426484,13.432545683836654,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM550M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,509.9,2.66,,,26.0,13.17,53.34,12.55,43.83,0.008806779,-0.14162303400000004,45.7,2.043079351283499,13.170003427885094,6.041933369572953e-11,0.2602597358157996,999999.9678370752,15.358016781342057,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM550N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,519.2,2.58,,,24.0,14.01,50.27,13.23,41.58,0.0063045,-0.1291939,45.17,1.7448037052549967,14.025262921207295,4.239074740370706e-12,0.24192161568647919,222.06246076045923,-4.184279900263633,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM550N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,550.0,515.2,2.58,,,24.0,13.83,50.68,13.09,42.02,0.006403290000000001,-0.13126120000000002,46.9,1.785802094371836,13.841296898635182,6.46494697132796e-12,0.2337365578581991,286.14726126371266,-1.4961131700656756,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM555M-72HL4,Jinko Solar Co Ltd,Mono-c-Si,0,555.0,520.5,2.5,,,24.0,14.12,49.72,13.54,40.99,0.0064484628,-0.1466774804,44.6,1.8289672929432732,14.120056397281257,2.20610057479803e-11,0.21337161003209,53421.22891422074,-4.683658751988883,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM555M-72HL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,555.0,520.5,2.5,,,24.0,14.12,49.72,13.54,40.99,0.0064484628,-0.1466774804,44.6,1.8289672929432732,14.120056397281257,2.20610057479803e-11,0.21337161003209,53421.22891422074,-4.683658751988883,-0.342039,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM555M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,555.0,514.7,2.66,,,26.0,13.26,53.44,12.63,43.95,0.008866961999999999,-0.141888544,45.7,2.0472656784233356,13.260003414780428,6.110904649615861e-11,0.2575045179467484,999999.9278170739,15.400469403572226,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM555M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,555.0,514.9,2.66,,,26.0,13.34,53.36,12.66,43.84,0.008296679599999999,-0.14435480799999997,45.5,2.0456438869219387,13.343439233832648,6.23891963016709e-11,0.2610452954236265,1012.5349740865195,13.445582076660996,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM555M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,555.0,514.7,2.66,,,26.0,13.26,53.44,12.63,43.95,0.008866961999999999,-0.141888544,45.7,2.0472656784233356,13.260003414780428,6.110904649615861e-11,0.2575045179467484,999999.9278170739,15.400469403572226,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM555N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,555.0,524.0,2.58,,,24.0,14.07,50.47,13.29,41.77,0.0063315,-0.12970790000000001,45.17,1.7520443191239659,14.084948728589392,4.279224093582395e-12,0.23974141286523093,225.6487341395263,-4.144373420495712,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM555N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,555.0,523.4,2.58,,,24.0,13.48,51.9,12.81,43.36,0.00601208,-0.137016,45.42,1.8107731717169775,13.487012916622342,4.767517292163737e-12,0.22020910797630902,423.2787791619725,-5.550793697916458,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM560M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,560.0,519.5,2.66,,,26.0,13.35,53.54,12.71,44.06,0.008927145000000001,-0.142154054,45.7,2.051417199503412,13.350096687832846,6.176892945099993e-11,0.25526516560345264,35245.37011622418,15.438037999703141,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM560M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,560.0,519.6,2.66,,,26.0,13.41,53.44,12.74,43.96,0.0083402154,-0.144571232,45.5,2.048970993388133,13.412358450449414,6.299551882643593e-11,0.2551917614045986,1451.0043865254731,13.482275859755777,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM560M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,560.0,519.5,2.66,,,26.0,13.35,53.54,12.71,44.06,0.008927145000000001,-0.142154054,45.7,2.051417199503412,13.350096687832846,6.176892945099993e-11,0.25526516560345264,35245.37011622418,15.438037999703141,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM560N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,560.0,528.8,2.58,,,24.0,14.13,50.67,13.35,41.95,0.0063585000000000004,-0.1302219,45.17,1.7590815863208942,14.144673293565948,4.305230596852718e-12,0.23843564479334797,229.60732419602678,-4.131018140884038,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM560N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,560.0,528.2,2.58,,,24.0,13.54,52.03,12.87,43.54,0.00603884,-0.13735920000000001,45.42,1.8165593851814599,13.546734490673535,4.884756161299516e-12,0.21347683636459241,429.20489679006874,-5.396763224833688,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM565M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,565.0,524.3,2.66,,,26.0,13.44,53.64,12.79,44.18,0.008987328,-0.142419564,45.7,2.056577391830595,13.440646494420456,6.320407418546343e-11,0.25059882978300374,5209.711779172114,15.59239577927173,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM565M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,565.0,524.4,2.66,,,26.0,13.48,53.53,12.82,44.08,0.0083837512,-0.14481470899999999,45.5,2.0524902434602317,13.481306651234679,6.345125027496931e-11,0.25020001595954755,2581.1761189057493,13.496557163459958,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM565M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,565.0,524.3,2.66,,,26.0,13.44,53.64,12.79,44.18,0.008987328,-0.142419564,45.7,2.056577391830595,13.440646494420456,6.320407418546343e-11,0.25059882978300374,5209.711779172114,15.59239577927173,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM565N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,565.0,533.7,2.58,,,24.0,13.77,51.9,13.01,43.43,0.006196499999999999,-0.133383,45.17,1.8111277562253825,13.782633851865615,4.863096932921014e-12,0.2101522029414991,229.05095532776252,-2.9537811076068063,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM565N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,565.0,532.3,2.58,,,24.0,13.77,51.9,13.01,43.43,0.005700779999999999,-0.128193,45.37,1.821727800311194,13.782314707348501,5.746956448760304e-12,0.20830164500129475,232.91772790058891,2.4482541941691953,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM565N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,565.0,533.0,2.58,,,24.0,13.6,52.16,12.93,43.72,0.006065600000000001,-0.1377024,45.42,1.8223442547474702,13.606461733012534,5.004043910309564e-12,0.20680859231563475,435.2697423300806,-5.243664024169223,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM570M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,570.0,529.0,2.66,,,26.0,13.52,53.74,12.87,44.29,0.009040824,-0.14268507400000002,45.7,2.0607741219386706,13.520384635030108,6.389128185822096e-11,0.24711434237391053,8686.12523828853,15.637046183017262,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM570M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,570.0,529.2,2.66,,,26.0,13.55,53.61,12.9,44.19,0.008427287,-0.145031133,45.5,2.055590508216619,13.5502874361338,6.387893920695545e-11,0.24538061381819737,11567.474511970631,13.506598189125379,-0.37122,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM570M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,570.0,529.0,2.66,,,26.0,13.52,53.74,12.87,44.29,0.009040824,-0.14268507400000002,45.7,2.0607741219386706,13.520384635030108,6.389128185822096e-11,0.24711434237391053,8686.12523828853,15.637046183017262,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM570N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,570.0,538.5,2.58,,,24.0,13.83,52.1,13.08,43.58,0.0062235,-0.13389700000000002,45.17,1.8169008269735578,13.841796732565012,4.798115861966032e-12,0.21162217415373585,248.09706049592668,-3.1003039424476055,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM570N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,570.0,537.1,2.58,,,24.0,13.83,52.1,13.08,43.58,0.00572562,-0.128687,45.37,1.8275422744492988,13.84148267098765,5.671472923966357e-12,0.20977529022662966,252.65831203517547,2.295846355889221,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM570N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,570.0,537.9,2.58,,,24.0,13.66,52.29,12.99,43.9,0.00609236,-0.13804560000000002,45.42,1.8281277946007917,13.666194599981083,5.125399701739414e-12,0.20020346606701622,441.4779586330709,-5.091486854446807,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM575M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,575.0,533.8,2.66,,,26.0,13.61,53.84,12.95,44.4,0.009101007,-0.14295058400000005,45.7,2.0656931026882726,13.610899993011635,6.516522444555749e-11,0.24345010032966932,3681.5363867329106,15.762078939430795,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM575M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,575.0,534.0,2.66,,,26.0,13.62,53.7,12.98,44.3,0.0084708228,-0.14527461,45.5,2.0601773725898553,13.620003253314055,6.515961592200916e-11,0.23884443378218848,999999.9763581492,13.640554244842827,-0.37122,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM575M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,575.0,533.8,2.66,,,26.0,13.61,53.84,12.95,44.4,0.009101007,-0.14295058400000005,45.7,2.0656931026882726,13.610899993011635,6.516522444555749e-11,0.24345010032966932,3681.5363867329106,15.762078939430795,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM575N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,575.0,543.3,2.58,,,24.0,13.89,52.3,13.15,43.73,0.0062505,-0.134411,45.17,1.8226793214240176,13.90094401744579,4.734831546964776e-12,0.2130746902842584,270.43153636191596,-3.24505708640924,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM575N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,575.0,541.9,2.58,,,24.0,13.89,52.3,13.15,43.73,0.00575046,-0.129181,45.37,1.8333621811913194,13.90063500273772,5.597948280002421e-12,0.21123143779211034,275.88189205497997,2.145280737076284,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM575N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,575.0,542.7,2.58,,,24.0,13.72,52.42,13.05,44.08,0.0061191200000000005,-0.1383888,45.42,1.8339100193773274,13.7259330477944,5.248842696093916e-12,0.193660565251095,447.834411060715,-4.9402231283084515,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM580M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,580.0,538.6,2.66,,,26.0,13.68,53.94,13.03,44.52,0.009147816,-0.14321609400000002,45.7,2.069597158229969,13.680003270031772,6.562188102669655e-11,0.23901671879917874,999999.9466008404,15.775744931915012,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM580M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,580.0,538.8,2.66,,,26.0,13.7,53.81,13.06,44.41,0.008520578,-0.145572193,45.5,2.0650437983769194,13.700003224080442,6.607923508723255e-11,0.2353158779836392,999999.9023616823,13.715620155842982,-0.37122,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM580M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,580.0,538.6,2.66,,,26.0,13.68,53.94,13.03,44.52,0.009147816,-0.14321609400000002,45.7,2.069597158229969,13.680003270031772,6.562188102669655e-11,0.23901671879917874,999999.9466008404,15.775744931915012,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM580N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,580.0,548.2,2.58,,,24.0,13.95,52.5,13.22,43.88,0.006277499999999999,-0.13492500000000002,45.17,1.8284631232153856,13.960075923897023,4.673184379740971e-12,0.2145100655628639,296.9867033269929,-3.3880751103908175,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM580N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,580.0,546.8,2.58,,,24.0,13.95,52.5,13.22,43.88,0.0057753,-0.129675,45.37,1.8391874250103815,13.959771932765703,5.526315776074516e-12,0.21267039915166225,303.599313067333,1.9965243943518456,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM580N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,580.0,547.5,2.58,,,24.0,13.78,52.55,13.11,44.26,0.00614588,-0.138732,45.42,1.8396909428943027,13.785677032049525,5.374391956776788e-12,0.18717901456593503,454.34424318955854,-4.789864822618508,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM585M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,585.0,543.4,2.66,,,26.0,13.75,54.04,13.11,44.63,0.009194625000000001,-0.143481604,45.7,2.074989432461819,13.75010946107009,6.725081637084795e-11,0.23593985779888726,29637.75625894261,15.95847109246236,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM585M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,585.0,543.5,2.66,,,26.0,13.78,53.92,13.14,44.52,0.0085703332,-0.145869776,45.5,2.069908424477046,13.780003194891362,6.700546006605761e-11,0.2318317417792091,999999.885076603,13.790171614738377,-0.37122,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM585M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,585.0,543.4,2.66,,,26.0,13.75,54.04,13.11,44.63,0.009194625000000001,-0.143481604,45.7,2.074989432461819,13.75010946107009,6.725081637084795e-11,0.23593985779888726,29637.75625894261,15.95847109246236,-0.36887,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM585N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,585.0,553.0,2.58,,,24.0,14.01,52.7,13.29,44.02,0.0063045,-0.135439,45.17,1.8340514193026325,14.019213882643541,4.59873124420787e-12,0.21678543108946616,329.6291058122267,-3.55429222524008,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM585N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,585.0,551.6,2.58,,,24.0,14.01,52.7,13.29,44.02,0.00580014,-0.130169,45.37,1.8448176811144434,14.018913961562895,5.4397346160408025e-12,0.21494952490000616,337.8343993636725,1.8236929721516295,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM585N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,585.0,552.4,2.58,,,24.0,13.84,52.68,13.17,44.44,0.00617264,-0.1390752,45.42,1.8454705785768077,13.845426508616686,5.5020664891398724e-12,0.18075795489160532,461.01283156506855,-4.640403624860388,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM590M-7RL4,Jinko Solar Co Ltd,Mono-c-Si,0,590.0,548.2,2.66,,,26.0,13.81,54.14,13.19,44.73,0.009234747,-0.143747114,45.7,2.0806351997872428,13.810003091786966,6.909695151841714e-11,0.2238631470315305,999999.8820087418,16.171734268791777,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM590M-7RL4-TV,Jinko Solar Co Ltd,Mono-c-Si,1,590.0,548.3,2.66,,,26.0,13.86,54.03,13.22,44.63,0.0086200884,-0.146167359,45.5,2.074771281441988,13.860003165747363,6.79382895013172e-11,0.22839118971422892,999999.9574091332,13.864215291125854,-0.37122,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM590M-7RL4-V,Jinko Solar Co Ltd,Mono-c-Si,0,590.0,548.2,2.66,,,26.0,13.81,54.14,13.19,44.73,0.009234747,-0.143747114,45.7,2.0806351997872428,13.810003091786966,6.909695151841714e-11,0.2238631470315305,999999.8820087418,16.171734268791777,-0.36887,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM590N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,590.0,555.4,2.7,,,22.0,15.72,47.88,14.08,39.87,0.0069168,-0.12305160000000002,46.03,1.7174216140751208,15.794424659845047,1.1346300763492361e-11,0.1806412626549439,38.15510397998,3.1388414653721197,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM590N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,590.0,557.9,2.58,,,24.0,14.07,52.9,13.36,44.17,0.0063315,-0.13595300000000002,45.17,1.8398459078274467,14.07831134065327,4.540436901791249e-12,0.21818283966370472,369.35467939951184,-3.693793734242169,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM590N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,590.0,556.4,2.58,,,24.0,14.07,52.9,13.36,44.17,0.0058249800000000004,-0.130663,45.37,1.8506536675776741,14.078016391045516,5.3719769246920995e-12,0.21635043133602438,379.72830526732815,1.6786012977869662,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM590N-72HL4-TV,Jinko Solar Co Ltd,Mono-c-Si,0,590.0,557.2,2.58,,,24.0,14.31,51.73,13.58,43.45,0.006382260000000001,-0.1365672,45.42,1.8106910138881434,14.31832162900906,5.540432827703432e-12,0.18722632674042666,321.9572384805658,-4.837567965396666,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM595N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,595.0,560.2,2.7,,,22.0,15.78,48.08,14.87,40.02,0.006943199999999999,-0.1235656,46.03,1.6815991488095627,15.79829833658573,5.928973437386774e-12,0.18518860811711713,159.70174266014436,-2.4352609830051057,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM595N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,595.0,562.7,2.58,,,24.0,14.13,53.1,13.43,44.31,0.0063585000000000004,-0.136467,45.17,1.845445350509361,14.137406461227638,4.469741731508041e-12,0.2204117783391992,420.5002050752451,-3.8562888645085196,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM595N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,595.0,561.3,2.58,,,24.0,14.13,53.1,13.43,44.31,0.00584982,-0.131157,45.37,1.8562950975207502,14.137115506023942,5.289735165541014e-12,0.21858304587844854,434.0630775300454,1.5096450202301215,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM600N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,600.0,565.0,2.7,,,22.0,15.84,48.28,14.94,40.16,0.0069696,-0.1240796,46.03,1.6873490990152518,15.857449010547471,5.833770078143879e-12,0.18730832775040104,170.03622595321065,-2.5994966674052384,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM600N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,600.0,567.5,2.58,,,24.0,14.19,53.3,13.5,44.45,0.0063855,-0.13698100000000002,45.17,1.8510503827636036,14.19647835330082,4.400963610933243e-12,0.22261584381285643,487.61137599930777,-4.0169048884458,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM600N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,600.0,566.1,2.58,,,24.0,14.19,53.3,13.5,44.45,0.005874659999999999,-0.13165100000000002,45.37,1.8619421483654173,14.196191359951342,5.2097086992555274e-12,0.2207907434393991,506.0310771476325,1.3426462101652634,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM605N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,605.0,569.8,2.7,,,22.0,15.9,48.48,15.01,40.31,0.006996,-0.12459359999999998,46.03,1.6933066624019424,15.916525757099844,5.760838472634348e-12,0.18864719725705204,181.5039629922607,-2.7343976783644512,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM605N-72HL4-BDV,Jinko Solar Co Ltd,Mono-c-Si,0,605.0,572.4,2.58,,,24.0,14.25,53.5,13.57,44.59,0.006412500000000001,-0.137495,45.17,1.8566608903017296,14.255527305412805,4.334033831151959e-12,0.22479545646498966,579.547361307651,-4.175676605133891,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM605N-72HL4-BDX,Jinko Solar Co Ltd,Mono-c-Si,0,605.0,571.0,2.58,,,24.0,14.25,53.5,13.57,44.59,0.0058995,-0.132145,45.37,1.8705886062497776,14.255167467322543,5.319372188528596e-12,0.22392807996230576,617.5122152586013,-1.5597873133494662,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM610N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,610.0,574.7,2.7,,,22.0,15.96,48.68,15.08,40.46,0.007022400000000001,-0.1251076,46.03,1.699267315455263,15.975586473231251,5.689676091024048e-12,0.1899727612383065,194.52542148888,-2.8677919706471022,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Jinko Solar Co Ltd JKM615N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,615.0,579.5,2.7,,,22.0,16.02,48.88,15.15,40.6,0.0070488,-0.1256216,46.03,1.7050273546737316,16.034668360788725,5.60114623347856e-12,0.19203816478876926,209.73382364206915,-3.02694117755525,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM620N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,620.0,584.3,2.7,,,22.0,16.08,49.08,15.22,40.74,0.007075199999999999,-0.12613560000000001,46.03,1.710790897752635,16.093724545564992,5.514951751249193e-12,0.19408362400079163,227.3929337306389,-3.1843424065038044,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM625N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,625.0,589.2,2.7,,,22.0,16.14,49.28,15.29,40.88,0.0071016000000000004,-0.1266496,46.03,1.7165577665344087,16.152755262085247,5.431002463761702e-12,0.19610944539045058,248.1490724066544,-3.340039877305264,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM630N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,630.0,594.0,2.7,,,22.0,16.2,49.48,15.36,41.02,0.007128,-0.1271636,46.03,1.722327989077152,16.211760915948418,5.349229621839001e-12,0.19811590211500532,272.89350768616833,-3.4940506150452855,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM635N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,635.0,598.9,2.7,,,22.0,16.26,49.68,15.43,41.16,0.007154400000000001,-0.1276776,46.03,1.7281014979562759,16.270741822542877,5.269559025361298e-12,0.2001032748386043,302.898247542867,-3.6464034815202555,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM640N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,640.0,603.7,2.7,,,22.0,16.32,49.88,15.5,41.3,0.0071808,-0.12819160000000002,46.03,1.733878363045336,16.32969839598054,5.191930328746331e-12,0.20207183097425532,340.0368780768015,-3.7971329483533007,-0.299,N,2025.7.3,6/23/2025,4.0,bootstrapping +Jinko Solar Co Ltd JKM645N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,645.0,608.5,2.7,,,22.0,16.38,50.08,15.57,41.44,0.0072071999999999995,-0.1287056,46.03,1.739658351986068,16.388630850471273,5.116262277454584e-12,0.20402183259405768,387.2014079720601,-3.9462176617661986,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinko Solar Co Ltd JKM650N-66HL4M-BDV,Jinko Solar Co Ltd,Mono-c-Si,1,650.0,613.4,2.7,,,22.0,16.44,50.28,15.64,41.57,0.007233600000000001,-0.12921960000000002,46.03,1.7452396068108011,16.447540835106107,5.025836618716065e-12,0.20668266236907776,450.59501022178017,-4.1199918877801505,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-85,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,85.0,74.1,0.6642460000000001,1.199,0.554,36.0,5.08,22.0,4.81,17.66,0.0018796000000000002,-0.091608,46.1,1.0061582440608565,5.109218937431358,1.6306198564711517e-09,0.30869831178204415,999999.9564664087,3.6909853634671688,-0.5597,N,2025.7.3,6/23/2025,2.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-90,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,90.0,78.6,0.6642460000000001,1.199,0.554,36.0,5.29,22.2,4.99,18.03,0.0019573,-0.0924408,46.1,1.022124177838262,5.293962722251371,1.954929677414865e-09,0.25036155937064825,999999.9576150982,4.93153969280798,-0.5597,N,2025.7.3,6/23/2025,2.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/36-95,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,95.0,83.1,0.6642460000000001,1.199,0.554,36.0,5.49,22.39,5.16,18.4,0.0020313,-0.09323196,46.1,1.0401979022610102,5.491323202981723,2.451202575447403e-09,0.19295050821045281,800.5587750255471,6.588513863081597,-0.5597,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-165,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,165.0,142.3,1.2766400000000002,1.58,0.808,72.0,5.2,43.51,4.79,34.45,0.0017888000000000001,-0.18213286,45.9,2.0773661826583427,5.21005010648409,4.076072631031952e-09,0.6825676263689834,353.16622476029096,11.119023175398416,-0.6046,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-170,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,170.0,146.8,1.2766400000000002,1.58,0.808,72.0,5.29,43.75,4.87,34.89,0.0018197600000000001,-0.1831375,45.9,2.099372700650889,5.299911538712365,4.598832450498022e-09,0.6120447093329318,326.66189390800326,12.077595178956804,-0.6046,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-175,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,175.0,151.3,1.2766400000000002,1.58,0.808,72.0,5.39,43.99,4.95,35.33,0.0018541599999999999,-0.18414214,45.9,2.1237841676215683,5.40045823103401,5.296988816415514e-09,0.5421877578890849,279.4350579486753,13.230855978379509,-0.6046,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-180,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,180.0,155.7,1.2766400000000002,1.58,0.808,72.0,5.48,44.23,5.03,35.77,0.0018851200000000003,-0.18514678,45.9,2.1457991534688734,5.489889166183076,5.946497831078658e-09,0.4762390823988143,263.9043423353366,14.168836024074512,-0.6046,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-185,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,185.0,160.2,1.2766400000000002,1.58,0.808,72.0,5.57,44.47,5.11,36.21,0.0019160800000000001,-0.18615142,45.9,2.16780903953735,5.579172268604861,6.660287281930255e-09,0.41240812611854855,250.44146723476362,15.096438140809097,-0.6046,N,2025.7.3,6/23/2025,4.0,first_pass +Jinzhou Jinmao Photovoltaic Technology JMPV-5M/72-190,Jinzhou Jinmao Photovoltaic Technology,Mono-c-Si,0,190.0,164.7,1.2766400000000002,1.58,0.808,72.0,5.66,44.71,5.18,36.65,0.0019470400000000001,-0.18715606,45.9,2.1925049405618338,5.668884398828238,7.614010695573875e-09,0.34946788576736065,222.6364163491604,16.239871207899235,-0.6046,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT108P-395,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,395.0,366.3,1.95,,,54.0,13.69,36.8,12.81,30.9,0.006160499999999999,-0.111872,43.8,1.4725492198353192,13.702204296194306,1.8784396833558907e-10,0.10861221918611189,121.83425395380112,10.290900322558151,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT108P-400,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,400.0,371.1,1.95,,,54.0,13.78,37.0,12.89,31.1,0.006201,-0.11248,43.8,1.4816506403952396,13.792208296816604,1.9252049024771315e-10,0.10555424549089813,119.14336308538994,10.452941401339066,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT108P-405,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,405.0,375.9,1.95,,,54.0,13.86,37.3,12.97,31.2,0.0062369999999999995,-0.11339199999999999,43.8,1.4893608212952796,13.873342463972516,1.8033050157607767e-10,0.11949034549573365,124.12521695710795,9.818082033691994,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT108P-410,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,410.0,380.7,1.95,,,54.0,13.94,37.5,13.05,31.4,0.006273,-0.11399999999999999,43.8,1.49789018681481,13.952857775483245,1.8309366057063383e-10,0.11657404976504676,126.38596008827554,9.900462086217754,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT108P-415,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,415.0,385.4,1.95,,,54.0,14.02,37.8,13.13,31.6,0.0063089999999999995,-0.114912,43.8,1.5082213166258647,14.033059574413771,1.7927496411071023e-10,0.12141826479301389,130.3475953683909,9.66137331334975,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD108N-R0-430,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,430.0,406.6,1.95,,,54.0,13.67,39.0,13.16,32.7,0.006288200000000001,-0.09282,43.3,1.3652594155311604,13.67000380157205,5.366737376981186e-12,0.15182860584789545,545960.3248239997,5.686328349583478,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD108N-R0-435,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,435.0,411.5,1.95,,,54.0,13.94,39.2,13.51,32.2,0.0064123999999999995,-0.093296,43.3,1.3936248113934764,13.940002298875697,8.479858229686556e-12,0.15927817452123624,965740.1775601654,9.55266711309167,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD108N-R0-440,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,440.0,416.3,1.95,,,54.0,13.77,39.3,13.36,32.9,0.006334199999999999,-0.09353399999999999,43.3,1.408620235382183,13.770001526457186,1.0526215116541962e-11,0.1085231863780798,978872.2458269743,11.618123949800232,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD96N-R2-440,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,440.0,417.1,2.0,,,48.0,15.8,35.2,14.91,29.5,0.00711,-0.084832,44.2,1.2213844894281705,15.81589115422609,4.729293714156113e-12,0.12207498954866557,121.37474766974056,2.138350159048907,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD108N-R0-445,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,445.0,421.2,1.95,,,54.0,13.82,39.5,13.46,33.1,0.0063572,-0.09401,43.3,1.4186444527500002,13.820001444774782,1.117471525185695e-11,0.09100809501223797,870228.0665952218,12.131118500833285,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD96N-R2-445,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,445.0,421.9,2.0,,,48.0,15.83,35.4,14.94,29.8,0.0071235,-0.08531399999999999,44.2,1.2308625848821946,15.844760996895035,5.027101674722701e-12,0.1124640165444959,120.60874805752195,2.6391804938598846,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD108N-R0-450,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,450.0,426.0,1.95,,,54.0,13.87,39.6,13.56,33.2,0.006380199999999999,-0.094248,43.3,1.4106702804520481,14.17251070765654,9.120830004088661e-12,0.14515575391436927,999999.8838949789,10.072285308948357,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD96N-R2-450,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,450.0,426.8,2.0,,,48.0,15.86,35.6,14.96,30.1,0.007136999999999999,-0.08579600000000001,44.2,1.2407167641441998,15.874184366288876,5.381305036828862e-12,0.10285656833603889,115.0072652004183,3.2047829655941866,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144P-535,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,535.0,493.9,2.59,,,72.0,13.79,49.5,12.9,41.5,0.0079982,-0.14553,45.4,1.9842629971052212,13.802759105924482,1.9779235495596521e-10,0.14991625470125994,162.02900303633606,14.31569802085827,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT144P-535,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,535.0,496.5,2.59,,,72.0,13.79,49.5,12.9,41.5,0.006205499999999999,-0.15048,43.8,1.9793588788143592,13.802903254651604,1.8591516667384927e-10,0.15074219627435886,161.10159788441138,10.135283425809309,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144P-540,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,540.0,498.7,2.58,,,72.0,13.86,49.6,12.97,41.6,0.0080388,-0.145824,45.4,1.9883266536260789,13.872479844103756,1.990083426411078e-10,0.14807084411142613,164.44612159905253,14.324246036779424,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT144P-540,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,540.0,501.2,2.59,,,72.0,13.86,49.6,12.97,41.6,0.0062369999999999995,-0.150784,43.8,1.9834123990261516,13.872622743130632,1.8705822998129062e-10,0.1488941914992751,163.48851680911523,10.143452610439551,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144P-545,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,545.0,503.5,2.58,,,72.0,13.93,49.8,13.04,41.8,0.0080794,-0.146412,45.4,1.9968192748142157,13.942101805593449,2.0127128512895976e-10,0.14510432014864855,167.0249305342147,14.38099171265818,-0.395,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT144P-545,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,545.0,506.0,2.59,,,72.0,13.93,49.8,13.04,41.8,0.0062685,-0.151392,43.8,1.9918880376362558,13.942242676415438,1.8919761376113152e-10,0.14592646964273834,166.03851242436272,10.198512680907307,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144P-550,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,550.0,508.2,2.58,,,72.0,14.0,49.9,13.11,42.0,0.00812,-0.146706,45.4,2.003479138027952,14.011197445669769,2.0909516110764114e-10,0.13444136905166373,168.09005188627722,14.686894239083031,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT144P-550,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,550.0,510.8,2.59,,,72.0,14.0,49.9,13.11,42.0,0.0063,-0.151696,43.8,1.9985571572180065,14.011332273606088,1.9663156750423307e-10,0.13525914658753474,167.10045749902005,10.49602161255483,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HT144P-555,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,555.0,515.6,2.59,,,72.0,14.07,50.1,13.18,42.1,0.0063315,-0.152304,43.8,2.004421092440325,14.081605199657046,1.9250889092086963e-10,0.14121257136956064,171.2043733661788,10.261375162919384,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-575,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,575.0,543.9,2.58,,,72.0,13.79,51.7,13.12,43.8,0.0063434,-0.123046,43.3,1.7856643310430487,13.795877306530336,3.643590483834197e-12,0.16697631952124256,391.7786894503948,2.328143849150198,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-580,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,580.0,548.7,2.58,,,72.0,13.95,52.5,13.22,43.9,0.006416999999999999,-0.12495,43.3,1.8778423751649447,13.958677085110493,9.95419122227784e-12,0.2044147830564928,328.63412077302644,11.036872586868228,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156P-580,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,580.0,546.1,2.8,,,78.0,13.79,53.6,12.9,45.0,0.006067599999999999,-0.13668000000000002,43.3,1.9702021619349392,13.807684549514944,2.057364635709432e-11,0.1875266131878704,146.22888512655894,10.081442811631739,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-585,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,585.0,553.6,2.58,,,72.0,14.01,52.7,13.29,44.0,0.0064446,-0.125426,43.3,1.8827640157886238,14.017912245864071,9.683666630311429e-12,0.21015865777514903,372.12225498665066,10.742887527837924,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156P-585,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,585.0,551.0,2.8,,,78.0,13.86,53.7,12.97,45.1,0.0060983999999999995,-0.136935,43.3,1.973894795320266,13.877380566842907,2.0690694466791114e-11,0.18555129385948982,147.96645969285183,10.085464963621044,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-590,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,590.0,558.4,2.58,,,72.0,13.94,52.4,13.28,44.4,0.0064123999999999995,-0.124712,43.3,1.8816185032117558,13.943550640261954,1.1150179961203929e-11,0.15444474677898898,606.3581847774645,12.057062028968653,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156P-590,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,590.0,555.8,2.8,,,78.0,13.93,53.9,13.04,45.3,0.0061292,-0.137445,43.3,1.9816170427321855,13.946964905576774,2.0908405616160763e-11,0.1825318896627405,149.8781836171017,10.132724205822793,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-R2-595,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,595.0,564.0,2.7,,,66.0,15.76,48.1,14.89,40.0,0.007091999999999999,-0.11592100000000001,44.2,1.6619684084010078,15.776089755548185,4.184998855217019e-12,0.1910695333344676,187.15361079362938,1.1253478181677954,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD144N-R0-600,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,600.0,568.1,2.58,,,72.0,14.04,52.8,13.39,44.8,0.0064583999999999996,-0.125664,43.3,1.8962506536998622,14.04278140644713,1.1287694806843415e-11,0.14945845747046518,754.437292080162,12.09893429987707,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-R2-610,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,610.0,578.5,2.7,,,66.0,15.86,49.0,14.96,40.8,0.007136999999999999,-0.11809,44.2,1.6953321997656858,15.877902422657856,4.36885700970545e-12,0.18945306273913043,167.83904442035978,1.4399094203106206,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-R2-615,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,615.0,583.4,2.7,,,66.0,15.9,49.3,15.0,41.0,0.007155,-0.11881299999999999,44.2,1.704611285882383,15.918027947204505,4.300146069520183e-12,0.1939179072713217,171.0286087702146,1.2849552481223705,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-R2-620,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,620.0,588.3,2.7,,,66.0,15.94,49.6,15.05,41.2,0.007172999999999999,-0.119536,44.2,1.71337704828483,15.957312216591003,4.200049479241556e-12,0.19837332615270978,182.64968010847548,1.0629903398936569,-0.292,N,2025.7.3,6/23/2025,4.0,bootstrapping +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-625,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,625.0,591.2,2.8,,,78.0,13.79,56.2,13.13,47.6,0.0063434,-0.133756,43.3,2.01817445797816,13.793901046407939,1.1039280479964428e-11,0.16909588228640837,597.7453194682187,12.067077157893,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-630,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,630.0,596.0,2.8,,,78.0,13.84,56.4,13.18,47.8,0.0063663999999999995,-0.134232,43.3,2.0258054155624485,13.84376112402622,1.1149604500597188e-11,0.16646453953601703,612.5480655836213,12.124312844290305,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-635,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,635.0,600.9,2.8,,,78.0,13.89,56.6,13.24,48.0,0.0063894,-0.134708,43.3,2.0327263539424583,13.893115951270481,1.1161243170512475e-11,0.16395670808633814,730.8710868905663,12.096515471164944,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD156N-R0-640,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,640.0,605.7,2.8,,,78.0,13.94,56.7,13.3,48.2,0.0064123999999999995,-0.134946,43.3,2.0377647500832388,13.942458156349199,1.1435068059542232e-11,0.15392713912814107,872.9075273586261,12.281916439237392,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-705,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,705.0,665.9,3.08,,,66.0,18.36,48.8,17.33,40.7,0.010098,-0.15128,41.9,1.8716615394437766,18.37182546496567,8.614301359402142e-11,0.135144870125125,209.8234507266684,-0.9678293359465865,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-710,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,710.0,670.7,3.08,,,66.0,18.4,49.0,17.36,40.9,0.01012,-0.1519,41.9,1.8805829179046787,18.41222291033735,8.778751799340512e-11,0.13315442120926205,200.44664730271535,-0.8318728708362921,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-715,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,715.0,675.6,3.08,,,66.0,18.44,49.2,17.4,41.1,0.010142,-0.15252000000000002,41.9,1.8889507226545792,18.451967716718087,8.88287694756764e-11,0.13122177061128773,202.1880647647542,-0.7549820981236042,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-720,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,720.0,680.4,3.08,,,66.0,18.49,49.4,17.44,41.3,0.0101695,-0.15314,41.9,1.8978443716721471,18.502308415118016,9.051638281629023e-11,0.1291785525816872,194.05516029466386,-0.6239142984814793,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-725,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,725.0,685.3,3.08,,,66.0,18.53,49.6,17.47,41.5,0.010191500000000001,-0.15376,41.9,1.9067727999005895,18.542658722785923,9.221178118579707e-11,0.12720966714406237,186.2111378811817,-0.4902872685183643,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-730,JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD,Mono-c-Si,1,730.0,690.1,3.08,,,66.0,18.57,49.8,17.51,41.7,0.0102135,-0.15438,41.9,1.9151405355006539,18.58239156522176,9.327454738625122e-11,0.1253032446723973,187.77944944140373,-0.4156985423859558,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Juli New Energy JLS155M,Juli New Energy,Mono-c-Si,0,155.0,132.6,1.2766400000000002,1.58,0.808,72.0,4.96,42.0,4.43,35.0,0.0024308959027641644,-0.18738461538461537,47.1,2.127029059019948,4.96751299860913,1.2336545367384516e-08,0.19545728587189304,129.0388974547487,14.713813707877012,-0.5943228858663512,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS160M,Juli New Energy,Mono-c-Si,0,160.0,137.0,1.2766400000000002,1.58,0.808,72.0,5.12,42.0,4.57,35.0,0.0025093118996275246,-0.18738461538461537,47.1,2.127975404539855,5.127818942096838,1.2836697233514408e-08,0.18874572709964585,123.59460177544872,14.793039343970436,-0.5943228858663512,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS165M,Juli New Energy,Mono-c-Si,0,165.0,141.5,1.2766400000000002,1.58,0.808,72.0,5.28,42.0,4.71,35.0,0.0025877278964908847,-0.18738461538461537,47.1,2.128866720862027,5.288124247401628,1.3337802472540628e-08,0.18247393413533383,118.59108049192285,14.867653533171188,-0.5943228858663512,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS170M,Juli New Energy,Mono-c-Si,0,170.0,148.6,1.2766400000000002,1.58,0.808,72.0,5.36,42.6,4.79,35.5,0.002220715630885123,-0.16734358288770054,46.5,2.030425028456136,5.370964983418712,3.867940702924307e-09,0.23763498303208092,116.16286614164041,17.716896493257547,-0.5424309392265193,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS175M,Juli New Energy,Mono-c-Si,0,175.0,153.1,1.2766400000000002,1.58,0.808,72.0,5.52,42.6,4.93,35.5,0.0022870056497175145,-0.16734358288770054,46.5,2.031249300941912,5.531387047336117,4.014466760560229e-09,0.23028349128125816,111.632561462305,17.79450075638166,-0.5424309392265193,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS180M,Juli New Energy,Mono-c-Si,0,180.0,157.6,1.2766400000000002,1.58,0.808,72.0,5.6,43.2,5.0,36.0,0.0023201506591337103,-0.1697005347593583,46.5,2.060259233503109,5.611597872520751,4.087837179233798e-09,0.22996831946079926,111.03958772174433,17.831708817680756,-0.5424309392265193,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS200M,Juli New Energy,Mono-c-Si,0,200.0,177.8,1.2766400000000002,1.58,0.808,60.0,7.86,34.2,7.02,28.5,0.006560607948174911,-0.12049740932642489,47.7,1.5640528021558806,7.879296433628295,2.333418007086999e-09,0.14958642391214985,60.93091987523797,21.64690094811742,-0.47102115915363385,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS205M,Juli New Energy,Mono-c-Si,0,205.0,182.4,1.2766400000000002,1.58,0.808,60.0,8.05,34.2,7.16,28.5,0.006719197707736391,-0.12049740932642489,47.7,1.5681444111363139,8.070885979067663,2.5173061397988078e-09,0.14451884228934514,55.70133109618021,22.181945077400965,-0.47102115915363385,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS210M,Juli New Energy,Mono-c-Si,0,210.0,187.0,1.2766400000000002,1.58,0.808,60.0,8.11,34.8,7.24,29.0,0.006769278684440015,-0.12261139896373058,47.7,1.5919458792028198,8.130036037945038,2.4213348698413347e-09,0.14735078536415977,59.64328047757928,21.7051968528362,-0.47102115915363385,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS215P,Juli New Energy,Multi-c-Si,0,215.0,188.6,1.2766400000000002,1.58,0.808,60.0,8.3,34.8,7.41,29.0,0.005561139028475712,-0.1330891462429302,47.7,1.6710071178149248,8.316689984787713,6.988016367531287e-09,0.12182254058692604,60.58288563992894,22.210631677978082,-0.5303430079155673,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS220P,Juli New Energy,Multi-c-Si,0,220.0,191.5,1.6367999999999998,1.65,0.992,60.0,8.36,35.4,7.46,29.5,0.0056013400335008364,-0.13538378669539453,47.7,1.700354032163709,8.376919530459741,7.080752675090273e-09,0.12283125648397686,60.69138052620857,22.27295292090943,-0.5303430079155673,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS225P,Juli New Energy,Multi-c-Si,0,225.0,196.0,1.6367999999999998,1.65,0.992,60.0,8.55,35.4,7.63,29.5,0.005728643216080402,-0.13538378669539453,47.7,1.7002871215484865,8.56729021619312,7.23628030775483e-09,0.12012635969400533,59.40242276246033,22.265179774831275,-0.5303430079155673,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS230P,Juli New Energy,Multi-c-Si,0,230.0,200.5,1.6367999999999998,1.65,0.992,60.0,8.59,36.0,7.67,30.0,0.005755443886097152,-0.13767842714785883,47.7,1.7284650318000387,8.607239542182935,7.2192577356963484e-09,0.12182850616551208,60.70388774062829,22.1920079664987,-0.5303430079155673,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60P240WH(156),Juli New Energy,Multi-c-Si,0,240.0,212.9,1.6367999999999998,1.65,0.992,60.0,8.56,37.2,8.01,30.0,0.0046224000000000005,-0.12871200000000002,47.1,1.6037084924020892,8.567908175787535,7.134306187679701e-10,0.31725495248268126,343.4045416684647,11.843614953517966,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60P245WH(156),Juli New Energy,Multi-c-Si,0,245.0,217.4,1.6367999999999998,1.65,0.992,60.0,8.69,37.4,8.12,30.2,0.0046926,-0.129404,47.1,1.614806854196391,8.699109414008888,7.490880201872755e-10,0.3084133622871216,294.21355258141085,12.155168129308143,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60M250WH(156),Juli New Energy,Mono-c-Si,0,250.0,221.6,1.6367999999999998,1.65,0.992,60.0,8.79,38.0,8.14,30.7,0.004658699999999999,-0.1387,47.0,1.66702358290698,8.805615057362589,1.0809561009946902e-09,0.30224809186308066,170.14099833906351,9.425780354640956,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60P250WH(156),Juli New Energy,Multi-c-Si,0,250.0,222.0,1.6367999999999998,1.65,0.992,60.0,8.81,37.6,8.23,30.4,0.0047574,-0.130096,47.1,1.6248873697047566,8.819358356887617,7.748793599485799e-10,0.30026078614422447,282.66697402890895,12.339797320915334,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60M255WH(156),Juli New Energy,Mono-c-Si,0,255.0,226.2,1.6367999999999998,1.65,0.992,60.0,8.81,38.5,8.23,31.0,0.0046693,-0.140525,47.0,1.6773646361996841,8.81905406263723,9.356227351392383e-10,0.3215351195642596,312.86791463138894,8.099943572560507,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60P255WH(156),Juli New Energy,Multi-c-Si,0,255.0,226.6,1.6367999999999998,1.65,0.992,60.0,8.83,37.8,8.25,30.9,0.0047682,-0.130788,47.1,1.644048474934041,8.83837434986941,8.995634505977543e-10,0.25253900115071987,266.27978353889824,13.690085024145247,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60M260WH(156),Juli New Energy,Mono-c-Si,0,260.0,230.8,1.6367999999999998,1.65,0.992,60.0,8.86,39.0,8.25,31.5,0.0046958,-0.14235,47.0,1.7053693966829333,8.87148176266381,1.0187585999022129e-09,0.309520977415473,238.84458444714568,8.811600814877313,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60P260WH(156),Juli New Energy,Multi-c-Si,0,260.0,231.2,1.6367999999999998,1.65,0.992,60.0,8.85,37.9,8.26,31.5,0.004778999999999999,-0.131134,47.1,1.6656311154853534,8.856992138404518,1.1401707780571845e-09,0.1781729863323031,225.5148914100741,15.888581230352568,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS60M265WH(156),Juli New Energy,Mono-c-Si,0,265.0,235.4,1.6367999999999998,1.65,0.992,60.0,8.95,39.1,8.41,31.5,0.0047434999999999995,-0.142715,47.0,1.698592202588701,8.954266897361427,8.956521207085361e-10,0.3195159074575247,670.1989198578632,7.560110338824235,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72P290WH(156),Juli New Energy,Multi-c-Si,0,290.0,257.4,1.9403519999999999,1.956,0.992,72.0,8.68,44.9,8.1,35.8,0.0046872,-0.155354,47.1,1.9255366709621802,8.69089670631352,6.391812513282735e-10,0.4375209122820547,348.5165872675977,10.732871739683452,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72P295WH(156),Juli New Energy,Multi-c-Si,0,295.0,261.9,1.9403519999999999,1.956,0.992,72.0,8.71,45.0,8.15,36.2,0.004703400000000001,-0.1557,47.1,1.9371680355693364,8.718173863597611,7.021568460914116e-10,0.39032627286296667,415.9285502987352,11.54147627018611,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72M300WH(156),Juli New Energy,Mono-c-Si,0,300.0,266.1,1.9403519999999999,1.956,0.992,72.0,8.81,45.5,8.21,36.5,0.0046693,-0.166075,47.0,1.9805485802178435,8.821348970687323,9.141486565068676e-10,0.3995453244330444,310.1599076486702,7.903440521649731,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72P300WH(156),Juli New Energy,Multi-c-Si,0,300.0,266.5,1.9403519999999999,1.956,0.992,72.0,8.8,45.1,8.21,36.5,0.004752,-0.156046,47.1,1.9515276193549298,8.810278740397488,7.962091134619334e-10,0.3551818152321831,304.0840426162312,12.602841298059463,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72M305WH(156),Juli New Energy,Mono-c-Si,0,305.0,270.6,1.9403519999999999,1.956,0.992,72.0,8.85,45.7,8.25,37.0,0.004690499999999999,-0.166805,47.0,1.9999693025661085,8.860365169227451,1.0378143171378781e-09,0.35047943426630207,299.24683532285627,8.982403584840142,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72P305WH(156),Juli New Energy,Multi-c-Si,0,305.0,271.1,1.9403519999999999,1.956,0.992,72.0,8.82,45.5,8.23,37.1,0.0047628,-0.15743,47.1,1.9773910422933414,8.829471881012667,8.813246105466645e-10,0.3176951688470412,295.8305958682714,13.51557381245013,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72M310WH(156),Juli New Energy,Mono-c-Si,0,310.0,275.2,1.9403519999999999,1.956,0.992,72.0,8.93,45.8,8.34,37.2,0.0047329,-0.16716999999999999,47.0,2.006141033788262,8.938805279610978,1.0707976645522785e-09,0.33137411251623144,336.06791586425555,9.174511766074204,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72P310WH(156),Juli New Energy,Multi-c-Si,0,310.0,275.7,1.9403519999999999,1.956,0.992,72.0,8.84,45.7,8.25,37.6,0.0047736,-0.15812199999999998,47.1,1.9965124569384398,8.848373373389336,9.953096679916375e-10,0.2699885315173822,285.0343776110116,14.623456361121791,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72M315WH(156),Juli New Energy,Mono-c-Si,0,315.0,279.8,1.9403519999999999,1.956,0.992,72.0,8.95,46.0,8.39,37.6,0.0047434999999999995,-0.1679,47.0,2.0183503728749326,8.955851365424197,1.120068605255125e-09,0.2990200234369375,457.3685680032697,9.543150831638822,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Juli New Energy JLS72M320WH(156),Juli New Energy,Mono-c-Si,0,320.0,284.4,1.9403519999999999,1.956,0.992,72.0,8.97,46.1,8.43,37.9,0.0047541,-0.168265,47.0,2.0268586471424657,8.974082856376109,1.1785830496456586e-09,0.2687711599333535,590.4882924420141,9.970119415573102,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Kaneka Corporation R-LVA760,Kaneka Corporation,Mono-c-Si,0,76.0,63.7,0.5,,,27.0,5.4,18.2,5.13,14.8,0.0022140000000000003,-0.055692,62.2,0.7184398972739517,5.402073874362983,5.379238079525302e-11,0.2442354467729315,999999.8344555803,6.749598227582917,-0.416,Y,2025.7.3,6/23/2025,2.0,first_pass +KB Solar LLC MODULE-KBS-375-MONO-BF,KB Solar LLC,Mono-c-Si,1,375.0,345.9,1.84,,,20.0,11.19,41.0,11.06,35.0,0.004023924,-0.1160587,46.3,1.6020421706273211,11.190000802060116,8.592235141133879e-11,0.0009999914707413782,13951.320869815869,13.120235559796335,-0.37954,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE200,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,200.0,181.5,1.31,,,48.0,8.64,29.62,8.17,24.71,0.00195264,-0.09140732,45.88,1.176462869579834,8.643528729888962,9.96856813204524e-11,0.16259960702952042,398.1207800682476,7.361238098954471,-0.4229,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE200P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,200.0,183.8,1.31,,,48.0,8.64,29.62,8.17,24.71,0.00283392,-0.08077374000000001,46.36,1.1053635225826541,8.645416088895727,1.967876115824719e-11,0.18161308824487457,289.7177521493989,6.573734153486791,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE205,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,205.0,186.2,1.31,,,48.0,8.73,29.81,8.28,24.95,0.00197298,-0.09199365999999999,45.88,1.1842530208508477,8.732016356188335,1.0157458713001649e-10,0.15091605093325877,653.4050222845792,7.421607199409249,-0.4229,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE205P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,205.0,188.5,1.31,,,48.0,8.77,29.86,8.3,24.92,0.0028765600000000002,-0.08142822,46.36,1.114079797097003,8.774992252786703,1.987898205901186e-11,0.1790879269367382,314.6076943008116,6.52866759829559,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE210,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,210.0,190.8,1.31,,,48.0,8.8,30.18,8.37,25.28,0.0019888,-0.09313547999999999,45.88,1.1977205823997326,8.800701923589228,1.0009835108227417e-10,0.14914619208657212,1869.842931842182,7.214747476306294,-0.4229,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE210P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,210.0,193.2,1.31,,,48.0,8.9,30.1,8.43,25.13,0.0029192000000000007,-0.08208270000000001,46.36,1.1228030010108718,8.904575144076349,2.008135357544977e-11,0.17663741020446752,343.6116864672165,6.485661528745487,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE215P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,215.0,197.9,1.31,,,48.0,9.03,30.34,8.56,25.34,0.00296184,-0.08273718,46.36,1.1315328020343476,9.03416457968892,2.0285779106725775e-11,0.17425829162210485,377.84182655014325,6.4446032997988905,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE220P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,220.0,202.6,1.31,,,48.0,9.16,30.58,8.69,25.55,0.0030044800000000003,-0.08339166,46.36,1.140268888751965,9.163760383217811,2.0492168517271567e-11,0.17194750940616307,418.8507182665139,6.405387765922579,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE225,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,225.0,202.6,1.46,1.96,0.99,54.0,8.64,33.32,8.17,27.8,0.00165888,-0.11258827999999999,45.88,1.372311550541212,8.642533030983136,2.4489518573395623e-10,0.16962612760323614,578.5835315824876,5.381908970705645,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE225P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,225.0,207.3,1.31,,,48.0,9.29,30.82,8.82,25.76,0.00304712,-0.08404614,46.36,1.1490109689930197,9.293362384627704,2.0700437579387526e-11,0.16970217355704828,468.873548170511,6.367916691756457,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE230,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,230.0,207.2,1.46,1.96,0.99,54.0,8.73,33.53,8.28,28.07,0.0016761599999999999,-0.11329787000000001,45.88,1.3813390915575035,8.731170810112273,2.4990182225995367e-10,0.15609153184391295,1163.8775106318494,5.4538741593792155,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE230M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,230.0,213.5,1.31,,,48.0,9.48,30.51,8.97,25.75,0.0028724400000000004,-0.07560378000000001,46.14,1.103462386635555,9.48581176302662,9.185090685050388e-12,0.14281733729197246,232.9600082600159,9.534177029781086,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE235,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,235.0,211.9,1.46,1.96,0.99,54.0,8.78,33.72,8.34,28.24,0.0016857599999999997,-0.11393988,45.88,1.3883425136162029,8.780524827995444,2.4817122245762064e-10,0.1548301885854848,2590.1998702567857,5.340623917813382,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE235M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,235.0,218.2,1.31,,,48.0,9.56,30.85,9.03,26.1,0.00289668,-0.0764463,46.14,1.1180068880838026,9.5664389313346,9.770038997924378e-12,0.1350476617996333,200.50775260217088,10.019027146197564,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE235P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,235.0,216.2,1.46,,,54.0,8.88,33.78,8.41,28.2,0.00291264,-0.09211806000000002,46.36,1.2600990039555056,8.88464009578049,2.0043273063261486e-11,0.1989914755910662,380.82065764012043,6.489217411828758,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE240,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,240.0,219.5,1.9404,1.96,0.99,72.0,8.48,37.14,7.93,30.27,0.00244224,-0.0906216,47.7,1.3346201409309943,8.496903723730432,6.80116888410088e-12,0.34625499474532684,173.70387801803076,9.612475532614445,-0.3431,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE240M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,240.0,223.0,1.31,,,48.0,9.64,31.15,9.09,26.41,0.0029209200000000005,-0.0771897,46.14,1.1309900996752371,9.64698790091924,1.0349808767640355e-11,0.12797314083364114,176.54244035564238,10.469497399082929,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE240P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,240.0,220.9,1.46,,,54.0,9.0,34.01,8.53,28.4,0.002952,-0.09274527,46.36,1.2684008324560399,9.004262634102803,2.0212292044767343e-11,0.19666941345521116,415.2420085555554,6.442767464655822,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE245,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,245.0,224.2,1.9404,1.96,0.99,72.0,8.55,37.53,8.0,30.65,0.0024624,-0.09157320000000001,47.7,1.3496319302980846,8.566246451899586,7.002986162624245e-12,0.33807985514593025,177.92085517853505,9.798263403305638,-0.3431,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE245M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,245.0,227.8,1.31,,,48.0,9.72,31.55,9.15,26.8,0.0029451600000000005,-0.0781809,46.14,1.1475218873106554,9.727470855792767,1.0927679344835927e-11,0.1219887075103466,158.71411161339108,10.892180413030957,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE245P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,245.0,225.6,1.46,,,54.0,9.12,34.24,8.65,28.6,0.0029913599999999998,-0.09337248000000001,46.36,1.276709381839754,9.123889514409948,2.0383068509893186e-11,0.19440868364161576,455.8428210522259,6.3980874201017075,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE250,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,250.0,225.9,1.63,1.96,0.99,60.0,8.64,37.02,8.17,30.89,0.00236736,-0.11905632000000001,45.88,1.5110323442248899,8.642770760582424,1.9651600741780511e-10,0.19162875505946275,597.551672527967,8.705063000180704,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE250M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,250.0,232.5,1.31,,,48.0,9.8,32.0,9.21,27.23,0.0029694,-0.079296,46.14,1.165842276268016,9.80788798399373,1.1512756760909723e-11,0.11657125071986588,144.8276594795343,11.29711776556382,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE250P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,250.0,230.3,1.46,,,54.0,9.24,34.47,8.77,28.8,0.0030307200000000006,-0.09399969,46.36,1.28502436229154,9.243520639820659,2.055552882176401e-11,0.19220690111184582,504.4514314586378,6.355092832774249,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE255,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,255.0,230.5,1.63,,,60.0,8.68,37.2,8.22,31.07,0.00237832,-0.11963520000000001,45.88,1.5179912475834867,8.682068535159837,1.9651848459459083e-10,0.1877194076429981,787.709461981965,8.658891078215118,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE255M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,255.0,237.3,1.31,,,48.0,9.88,32.45,9.27,27.66,0.0029936400000000005,-0.0804111,46.14,1.184185860987641,9.8882287149931,1.2117977141094904e-11,0.11121384670825817,133.5315184538043,11.695490533193485,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE255P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,255.0,235.1,1.46,,,54.0,9.36,34.7,8.89,29.0,0.00307008,-0.09462690000000001,46.36,1.2933455004196865,9.36315591629186,2.0729603883165947e-11,0.1900618021628999,563.6963261486918,6.313704251887037,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE260,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,260.0,235.1,1.63,,,60.0,8.78,37.37,8.34,31.3,0.0024057199999999996,-0.12018192,45.88,1.52484633912565,8.780715985613684,1.991788259999513e-10,0.1746979940271305,2142.2904290278043,8.664195154683608,-0.4422,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE260P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,260.0,239.1,1.63,,,60.0,9.0,37.5,8.5,30.7,0.002952,-0.1022625,46.36,1.3868842509165815,9.007516181236861,1.6093022382086915e-11,0.2997148965103465,358.88358971173517,4.508198314252878,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE265,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,265.0,239.8,1.63,,,60.0,8.88,37.61,8.46,31.54,0.00243312,-0.12095376,45.88,1.5342426611553113,8.891055806869197,2.008060341225092e-10,0.16860594326462963,999999.8987671542,8.618951230473785,-0.4422,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE265P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,265.0,243.9,1.63,,,60.0,9.15,37.7,8.61,30.9,0.0030012000000000007,-0.10280790000000002,46.36,1.3975639550333767,9.160556533909281,1.7356955652748076e-11,0.29145739877987603,252.62413277600493,5.0250148952334,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE270M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,270.0,250.9,1.46,,,54.0,9.26,38.7,8.76,31.4,0.00280578,-0.0958986,46.14,1.3732216050973285,9.268194350701473,5.2862217582711206e-12,0.3503896399784025,395.9567029212009,4.902223041413365,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE270P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,270.0,248.6,1.63,,,60.0,9.22,37.9,8.73,31.0,0.0030241600000000006,-0.1033533,46.36,1.399359906792568,9.225588802949739,1.581307016558313e-11,0.29933951769280337,493.8285401780161,4.14492308124866,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE275M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,275.0,255.7,1.46,,,54.0,9.26,38.7,8.76,31.4,0.00280578,-0.0958986,46.14,1.3732216050973285,9.268194350701473,5.2862217582711206e-12,0.3503896399784025,395.9567029212009,4.902223041413365,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE275P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,275.0,253.3,1.63,,,60.0,9.32,38.1,8.84,31.2,0.0030569600000000005,-0.1038987,46.36,1.4064283022646342,9.324184127642596,1.5918029766112606e-11,0.29294999606034267,652.5360246857097,4.102685135240186,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE280M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,280.0,260.5,1.46,,,54.0,9.35,39.0,8.84,31.7,0.00283305,-0.096642,46.14,1.38542552125675,9.358802380110449,5.504788380145304e-12,0.3423940732638522,363.6953445812563,5.170029357680916,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE280P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,280.0,258.0,1.63,,,60.0,9.4,38.2,8.92,31.5,0.0030832000000000004,-0.10417140000000001,46.36,1.4147747862462365,9.40388971004778,1.7548530837717745e-11,0.2630592172765528,635.7174865678926,4.855032551658096,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE285M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,285.0,265.2,1.46,,,54.0,9.45,39.3,8.97,31.8,0.00286335,-0.09738539999999998,46.14,1.3905937784699305,9.454885334392696,5.00406151147711e-12,0.35956151689155336,695.5217594450685,4.243717453116909,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE285P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,285.0,262.7,1.63,,,60.0,9.49,38.4,9.02,31.65,0.0031127200000000002,-0.1047168,46.36,1.420753103804927,9.492675968660258,1.7275525630438472e-11,0.2638977741782326,935.8816460368447,4.634216824006368,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE295M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,295.0,274.0,1.63,,,60.0,9.55,39.7,9.08,32.5,0.0028936500000000006,-0.09837660000000001,46.14,1.4116058460479555,9.553655545791013,5.805652469390167e-12,0.31177228140538393,814.4954244896403,5.422154696714671,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE295MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,295.0,273.7,1.61,,,60.0,9.68,39.6,9.08,32.5,0.0030588800000000004,-0.10454400000000001,44.43,1.486847340779784,9.6931271744272,2.5762689497131307e-11,0.28011805324273176,206.55951500223762,11.538504233511789,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE300,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,300.0,273.6,1.93,,,72.0,8.64,44.42,8.17,37.07,0.00240192,-0.13672476000000003,45.88,1.7385447680054025,8.643944483644313,6.860079679898644e-11,0.24886681039410818,545.1180755434814,4.402557242765799,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE300M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,300.0,278.8,1.63,,,60.0,9.64,39.9,9.19,32.6,0.0029209200000000005,-0.09887220000000001,46.14,1.4157091337921754,9.64114366694707,5.5387102354090636e-12,0.3182913088486254,2682.886253993134,4.924468491812901,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE300MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,300.0,278.4,1.61,,,60.0,9.77,39.8,9.19,32.7,0.00308732,-0.105072,44.43,1.4931802247336292,9.7808224082822,2.5543205997739906e-11,0.274538789889938,247.8416904085114,11.366090868838517,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE305,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,305.0,278.2,1.93,,,72.0,8.68,44.64,8.22,37.28,0.00241304,-0.13740192,45.88,1.7464889446207816,8.683180788466618,6.83644408038186e-11,0.24549243676732047,669.9202043697314,4.328911613509258,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE305M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,305.0,283.5,1.63,,,60.0,9.85,40.0,9.28,32.9,0.0029845500000000003,-0.09912,46.14,1.43145383169282,9.861760188704654,7.092004490429326e-12,0.28564123366977257,239.244927596743,6.931090721015245,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE305MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,305.0,283.2,1.61,,,60.0,9.85,40.0,9.28,32.9,0.0031126000000000005,-0.10560000000000001,44.43,1.5003647981824204,9.859508808081209,2.5652082333908334e-11,0.2693028371285222,278.96587645671207,11.324193560445034,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE310,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,310.0,282.9,1.93,,,72.0,8.78,44.85,8.34,37.56,0.0024408399999999997,-0.1380483,45.88,1.7545908117987765,8.781664546399972,6.926574642604317e-11,0.22986113870662397,1212.4510191963293,4.330701236883879,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE310M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,310.0,288.3,1.63,,,60.0,9.94,40.2,9.37,33.1,0.00301182,-0.0996156,46.14,1.4389970327221846,9.951275559925813,7.214580445831615e-12,0.28013210845729475,246.95121013427297,6.998973952933608,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE310MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,310.0,288.0,1.61,,,60.0,9.94,40.2,9.37,33.1,0.0031410400000000003,-0.10612800000000001,44.43,1.5082899457056829,9.949055993272538,2.6095115523493665e-11,0.26384986531313526,289.6057469892116,11.3942021417583,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE315,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,315.0,287.6,1.93,,,72.0,8.8,45.27,8.37,37.92,0.0024464,-0.13934106000000002,45.88,1.7700384877112239,8.801032930969999,6.854931923537826e-11,0.23059784309529163,1964.5662365611158,4.2190615909024975,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE315M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,315.0,293.1,1.63,,,60.0,9.95,40.5,9.46,33.3,0.00301485,-0.100359,46.14,1.4431058756370814,9.953930526081715,6.416787173838533e-12,0.28770667110067605,728.3201656018582,5.9329733865168235,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE315MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,315.0,292.7,1.61,,,60.0,9.95,40.5,9.46,33.3,0.0031442,-0.10692000000000002,44.43,1.5122726199998326,9.952088651294238,2.3214299310718364e-11,0.2716563486998024,1294.1273760345996,10.298628499804055,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE315P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,315.0,289.9,1.93,,,72.0,9.0,45.6,8.51,37.2,0.002952,-0.12435120000000001,46.36,1.6825013392393777,9.006643186438295,1.5129621389721688e-11,0.38225372487961523,517.8664641825101,3.9812098121376933,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE320M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,320.0,297.8,1.63,,,60.0,9.96,40.8,9.55,33.7,0.00301788,-0.1011024,46.14,1.4559697972693169,9.96000256053147,6.733095790922798e-12,0.2570772316965201,999996.1427579466,6.319262327618136,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE320MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,320.0,297.5,1.61,,,60.0,9.96,40.8,9.55,33.7,0.0031473600000000005,-0.107712,44.43,1.5285121982307974,9.960002319224664,2.5456503007322907e-11,0.23284386688822362,999996.0688574623,11.101511883032057,-0.374,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE320P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,320.0,294.6,1.93,,,72.0,9.15,45.5,8.63,37.2,0.0030012000000000007,-0.12407850000000001,46.36,1.6826969042009714,9.158830676372919,1.6322817771897618e-11,0.3642665179911463,377.4386568150638,4.493656900138304,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE325M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,325.0,302.6,1.63,,,60.0,9.97,41.1,9.64,33.8,0.0030209100000000003,-0.1018458,46.14,1.4690649077319708,9.970002538673462,7.054157987140697e-12,0.23785424872735342,934122.6598533776,6.7147364673524415,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE325MLS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,325.0,302.3,1.61,,,60.0,9.97,41.1,9.64,33.8,0.003150520000000001,-0.10850400000000002,44.43,1.5423491249875738,9.970002113613878,2.6653876533844545e-11,0.21194475409895597,999788.7156834976,11.505154871092431,-0.374,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE325P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,325.0,299.3,1.93,,,72.0,9.19,45.6,8.73,37.3,0.00301432,-0.12435120000000001,46.36,1.6811323620702174,9.19282779718904,1.5189954875644653e-11,0.3610992490951761,1173.5281651719692,3.8199724522549534,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE330P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,330.0,304.0,1.93,,,72.0,9.28,45.8,8.83,37.5,0.00304384,-0.12489659999999998,46.36,1.6880362114070384,9.281506714808975,1.5251266077834115e-11,0.35441744217402127,2182.890708632934,3.7651389165107045,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE335P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,335.0,308.8,1.93,,,72.0,9.35,46.0,8.91,37.7,0.0030668,-0.125442,46.36,1.6944886278590494,9.350008929913447,1.517352030556005e-11,0.348743477867567,365152.91592826956,3.6513670714640605,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE340M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,340.0,315.5,1.97,,,72.0,9.45,46.5,8.9,38.2,0.00286335,-0.115227,46.14,1.6633515197591942,9.461702897120105,6.7209480162488476e-12,0.352068338162319,284.2924938716906,6.825325104784983,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE340P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,340.0,313.5,1.93,,,72.0,9.42,46.2,8.99,37.9,0.0030897600000000004,-0.1259874,46.36,1.7036240304503685,9.42000396633131,1.5724045426405412e-11,0.3425831204211414,813649.9436033173,3.887925098619947,-0.3627,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE345M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,345.0,320.2,1.97,,,72.0,9.5,46.7,9.0,38.4,0.0028785,-0.11572260000000001,46.14,1.6667602296886808,9.50674360797495,6.388509136853273e-12,0.3471842322002087,489.0928176183759,6.311891776980143,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE345P,KOSOL ENERGIE PVT LTD,Multi-c-Si,0,345.0,318.2,1.93,,,72.0,9.49,46.4,9.07,38.1,0.0031127200000000002,-0.1265328,46.36,1.7127257330690473,9.490003097173373,1.6279972884566986e-11,0.3263529080771816,999999.6365316098,4.117930308668595,-0.3627,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE350M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,350.0,325.0,1.97,,,72.0,9.6,46.9,9.09,38.5,0.0029088,-0.1162182,46.14,1.6729369748145975,9.60731617395467,6.349822152942642e-12,0.35316175923288756,463.4048212117042,6.170398323545503,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE355M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,355.0,329.7,1.97,,,72.0,9.69,47.0,9.17,38.7,0.0029360700000000003,-0.116466,46.14,1.6794240235635602,9.697742509665906,6.722993108721556e-12,0.33589879050206345,420.3879938493876,6.58844008038153,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE355MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,355.0,330.6,2.0,,,72.0,9.68,46.9,9.21,38.6,0.00298144,-0.12086129999999999,45.42,1.672030970775307,9.683208504259847,6.340313382756274e-12,0.3376135995603991,1018.5741639463854,1.9648850673006548,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE360M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,360.0,334.5,1.97,,,72.0,9.7,47.7,9.24,39.0,0.0029390999999999996,-0.1182006,46.14,1.6936127875394968,9.701922673468296,5.675158489678982e-12,0.3748376521802987,1891.0693936243008,5.083754177744995,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE360MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,360.0,335.3,2.0,,,72.0,9.73,47.2,9.28,38.8,0.0029968400000000006,-0.1216344,45.42,1.6780668508253314,9.73000778828744,5.921681535957103e-12,0.3442108045463602,430028.7253650283,1.3388777079978278,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE365M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,365.0,339.2,1.97,,,72.0,9.88,48.0,9.77,39.3,0.0029936400000000005,-0.118944,46.14,1.7284631001276325,9.880001973561559,8.595110371313137e-12,0.19583896933287975,980412.6069218433,8.524090544419348,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE365MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,365.0,340.1,2.0,,,72.0,9.83,47.6,9.37,39.0,0.00302764,-0.1226652,45.42,1.6918787483823214,9.831439380354025,5.931194204438891e-12,0.3589460576169808,2451.360294700218,1.2746854959555345,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE370M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,370.0,344.0,1.97,,,72.0,9.83,48.3,9.33,39.7,0.00297849,-0.1196874,46.14,1.7220819011134008,9.835365695407722,6.435616405641877e-12,0.348945096421313,639.270413569505,6.071026212110431,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE370MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,370.0,344.9,2.0,,,72.0,9.88,47.6,9.44,39.2,0.0030430400000000003,-0.1226652,45.42,1.6948051478927393,9.880004456906182,6.2695401732958e-12,0.33270804070872456,737548.166139826,1.68474934652248,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE375M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,375.0,348.8,1.97,,,72.0,9.88,48.5,9.37,41.1,0.0029936400000000005,-0.120183,46.14,1.7556731478440522,9.884525260513632,9.83392307469126e-12,0.19789059828498465,432.0544746064386,9.764285919110335,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE375MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,375.0,349.6,2.0,,,72.0,9.93,47.8,9.52,39.4,0.00305844,-0.12318059999999999,45.42,1.7049185465186631,9.930003093780504,6.619680317492566e-12,0.3115544706869256,999996.580712173,2.0941492012166796,-0.3357,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-380-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,380.0,356.9,1.95,,,54.0,13.41,36.1,12.65,30.0,0.0045594,-0.09169400000000001,43.2,1.3133464854029424,13.42240491249254,1.5258144145842933e-11,0.15872591611548476,171.58647245865842,8.206080589179086,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE380M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,380.0,353.5,1.97,,,72.0,9.9,48.9,9.39,40.5,0.0029997,-0.1211742,46.14,1.750450683803841,9.9058171615574,7.236816141824249e-12,0.3133776253224927,533.325136641139,7.0342407757329335,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE380MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,380.0,354.4,2.0,,,72.0,9.99,48.0,9.6,39.6,0.0030769200000000003,-0.12369599999999999,45.42,1.7143291170925727,9.990003062990251,6.912351809101002e-12,0.2958258057232047,964850.6595742285,2.4043787170793425,-0.3357,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-385-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,385.0,361.7,1.95,,,54.0,13.53,36.2,12.77,30.2,0.0046002000000000005,-0.09194800000000002,43.2,1.3191870418949339,13.541438623790054,1.6121742881656316e-11,0.14728287277002153,174.2112788040011,8.61115276652098,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE385M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,385.0,358.3,1.97,,,72.0,9.92,49.1,9.44,40.8,0.00300576,-0.12166980000000001,46.14,1.75776443589951,9.923281426634103,7.294983409618698e-12,0.2978859202201536,900.5315931754326,7.072022383075365,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE385MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,385.0,359.2,2.0,,,72.0,10.03,48.5,9.61,40.1,0.00308924,-0.12498449999999998,45.42,1.73166669130135,10.030004409021005,6.881908976963366e-12,0.3142681954761103,714928.2827518682,2.334251999180126,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-390-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,390.0,366.5,1.95,,,54.0,13.65,36.3,12.88,30.3,0.004641000000000001,-0.09220199999999999,43.2,1.3233501211423422,13.66168609826632,1.6434957795136353e-11,0.14490223892170634,169.253717113251,8.704343046888456,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE390M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,390.0,363.1,1.97,,,72.0,9.93,49.3,9.47,41.2,0.00300879,-0.1221654,46.14,1.7680199086615835,9.93182239609163,7.683636882749939e-12,0.2707200495950909,1475.1177087722708,7.5083120885287205,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE390MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,390.0,364.0,2.0,,,72.0,10.08,49.7,9.64,40.5,0.00310464,-0.1280769,45.42,1.7626462237589513,10.080005346708516,5.727768005876463e-12,0.3909226282745459,737002.089628147,0.7729419948666648,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-395-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,395.0,371.3,1.95,,,54.0,13.76,36.5,12.98,30.4,0.0046784,-0.09271,43.2,1.3293739764519494,13.772399072656144,1.613760906602382e-11,0.1504310414634215,166.94250436409592,8.473228378249413,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE395M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,395.0,367.8,1.97,,,72.0,9.93,49.5,9.52,41.5,0.00300879,-0.12266099999999999,46.14,1.7772040949097079,9.930003675193344,7.955287175046224e-12,0.2555763961030593,690546.2630535257,7.799341770507491,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE395MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,395.0,368.7,2.0,,,72.0,10.13,50.1,9.69,40.8,0.0031200400000000006,-0.1291077,45.42,1.7765385392130384,10.130005467538023,5.729384815586399e-12,0.3950940397988001,732018.3817978704,0.7345707479687598,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE395T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,395.0,372.1,1.94,,,18.0,13.69,36.8,12.81,30.9,0.0060236,-0.108928,43.2,1.3582987147425196,13.707027323656037,2.2870454397636068e-11,0.1283126617405746,103.16361989425806,-4.3822390255599055,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-400-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,400.0,376.1,1.95,,,54.0,13.89,36.6,13.1,30.5,0.0047226,-0.09296400000000002,43.2,1.3103166114016094,13.903641325386968,1.0113060730528812e-11,0.15192063657500807,154.69007507938434,4.354567126864274,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE400M,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,400.0,372.6,1.97,,,72.0,9.94,49.7,9.57,41.8,0.00301182,-0.1231566,46.14,1.7897998643847317,9.94000211578344,8.663470787680682e-12,0.21002050605733805,986689.3518676063,8.540565458533006,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE400MX,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,400.0,373.5,2.0,,,72.0,10.18,51.03,9.72,41.16,0.00313544,-0.13150430999999999,45.42,1.8011119017078927,10.180006134405177,5.047745077364584e-12,0.4477587778761764,743059.4486598877,-0.34239385572172554,-0.3357,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE400T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,400.0,376.9,1.94,,,18.0,13.78,37.0,12.89,31.1,0.0060631999999999995,-0.10951999999999999,43.2,1.3666450233663459,13.79704920044483,2.3453847375622117e-11,0.12527777342456603,101.25564126605941,-4.236065116767387,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE405T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,405.0,381.8,1.94,,,18.0,13.86,37.3,12.97,31.2,0.0060983999999999995,-0.11040799999999999,43.2,1.373946125531011,13.87841938322984,2.1916968860703714e-11,0.13909177107548273,104.66213390645206,-4.8087740893562545,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-410-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,410.0,385.8,1.95,,,54.0,14.12,36.9,13.32,30.8,0.0048008,-0.093726,43.2,1.3303281979187567,14.120003903699796,1.2686683158866549e-11,0.14483228761481742,523876.3935281844,5.37229215155856,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE410T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,410.0,386.6,1.94,,,18.0,13.94,37.5,13.05,31.4,0.0061335999999999995,-0.11099999999999999,43.2,1.3817917467582346,13.957859887498392,2.2259885426217626e-11,0.13618368070165343,106.29409154025964,-4.7344489627305055,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-415-54XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,415.0,390.6,1.95,,,54.0,14.21,37.1,13.43,30.9,0.0048314000000000005,-0.094234,43.2,1.3500160704743198,14.220932229567351,1.6296330909941502e-11,0.14813196976061668,192.54583788222408,8.267431682373257,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE415T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,415.0,391.4,1.94,,,18.0,14.02,37.8,13.13,31.6,0.0061687999999999995,-0.111888,43.2,1.3913957349896777,14.03812977555439,2.1776444279563256e-11,0.14100594543139544,109.0418001302304,-4.950119332900352,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE420N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,420.0,399.2,1.94,,,18.0,13.42,39.4,12.84,32.7,0.0059048,-0.08865,43.1,1.3478761416329723,13.420649117667525,2.7071537457181823e-12,0.19059689189975068,3940.4413080095574,5.8839009109804685,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE420T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,420.0,396.3,1.94,,,18.0,14.1,38.0,13.22,31.8,0.0062039999999999994,-0.11248,43.2,1.3987093671394737,14.116928280531916,2.1907466010786267e-11,0.138181118457225,115.09460599712344,-4.951706941135746,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-425-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,425.0,399.2,2.17,,,60.0,13.37,40.2,12.66,33.6,0.0045458,-0.102108,43.2,1.4431647882792902,13.378914306541423,1.0558609573627848e-11,0.1637125720074879,245.54204937767167,5.029677154761112,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE425N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,425.0,404.0,1.94,,,18.0,13.51,39.6,12.92,32.9,0.0059444,-0.08910000000000001,43.1,1.355631426127221,13.511237329672822,2.7777153438865393e-12,0.1872990091129002,2045.0569406095008,6.053940046929555,-0.293,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE-430-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,430.0,404.0,2.17,,,60.0,13.46,40.4,12.75,33.7,0.004576400000000001,-0.102616,43.2,1.4696380479150368,13.468114552003845,1.53423480626196e-11,0.16579462343495832,275.0115651264361,8.203866770259284,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE430N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,430.0,408.9,1.94,,,18.0,13.6,39.7,13.0,33.1,0.005984,-0.089325,43.1,1.3615245589019083,13.601931297878645,2.9458270264850037e-12,0.1763198932523247,1241.6264693260675,6.516770186105644,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-435-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,435.0,408.8,2.17,,,60.0,13.55,40.5,12.83,33.9,0.004607000000000001,-0.10287,43.2,1.47606870611347,13.55821275341531,1.6256481947869962e-11,0.15467050293312543,255.1866860934464,8.657756452661879,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE435N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,435.0,413.7,1.94,,,18.0,13.69,39.9,13.08,33.3,0.0060236,-0.08977500000000001,43.1,1.3692804892140549,13.692451020546912,3.0206040420140266e-12,0.1731505720893587,967.1201477852975,6.682529256615203,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-440-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,440.0,413.6,2.17,,,60.0,13.66,40.6,12.91,34.1,0.0046444,-0.10312400000000001,43.2,1.483537433183889,13.669403607466512,1.754544774564429e-11,0.14335410436782833,208.24104821962558,9.270852637905,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE440N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,440.0,418.6,1.94,,,18.0,13.78,40.0,13.16,33.4,0.0060631999999999995,-0.09000000000000001,43.1,1.3732933374573257,13.78293916025109,3.0764140081140474e-12,0.17101473160194408,801.7881953158837,6.788866189125181,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE440R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,440.0,418.4,1.98,,,18.0,15.73,35.2,14.96,29.4,0.0066066,-0.083424,43.1,1.2114337404170976,15.738038660301097,3.7503991456427536e-12,0.13105685235853018,256.4512262838931,1.947966330190542,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-445-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,445.0,418.5,2.17,,,60.0,13.72,40.9,13.0,34.2,0.004664800000000001,-0.10388599999999999,43.2,1.4894084644040864,13.727804825708985,1.6103721059335462e-11,0.15737809812993134,276.6528813876334,8.461093127034236,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE445N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,445.0,423.5,1.94,,,18.0,13.87,40.2,13.24,33.6,0.006102799999999999,-0.09045,43.1,1.3810491961114209,13.873426174254792,3.153208261100298e-12,0.16791608445486128,679.7658062326268,6.952032397502582,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE445R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,445.0,423.3,1.98,,,18.0,15.78,35.4,15.01,29.7,0.0066276,-0.08389799999999999,43.1,1.2207809156672822,15.78760349430685,3.988715905451991e-12,0.12132967816937835,251.8029538836263,2.442515896933573,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-450-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,450.0,423.3,2.17,,,60.0,13.8,41.1,13.09,34.4,0.004692000000000001,-0.10439400000000001,43.2,1.4966273165373059,13.806820039923954,1.6197643990140224e-11,0.1544379092001904,312.4971681959102,8.45636360951781,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE450N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,450.0,428.3,1.94,,,18.0,13.96,40.3,13.32,33.8,0.0061424,-0.09067499999999999,43.1,1.3869409370079402,13.963894892307586,3.3388018413672795e-12,0.15732294943826494,563.8739688837506,7.405528400975875,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE450R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,450.0,428.1,1.98,,,18.0,15.83,35.6,15.06,29.9,0.0066486,-0.084372,43.1,1.2282065141903549,15.837385963953551,4.051973177083621e-12,0.11920824698407137,255.4936046725797,2.548621754296907,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-455-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,455.0,428.1,2.17,,,60.0,13.92,41.4,13.16,34.6,0.0047328,-0.105156,43.2,1.5088270697887913,13.92998825880342,1.6659514759535185e-11,0.15843603120916502,220.80220475622068,8.642808511055486,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE455N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,455.0,433.2,1.94,,,18.0,14.05,40.5,13.4,34.0,0.006182,-0.09112500000000001,43.1,1.3946973640728677,14.05431791613357,3.419993219657217e-12,0.15434385711645118,502.217072547287,7.564560960557895,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE455R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,455.0,433.0,1.98,,,18.0,15.88,35.8,15.11,30.1,0.006669600000000001,-0.08484599999999999,43.1,1.235631069237917,15.887172333909875,4.1154758130715525e-12,0.11710142972867794,259.26995760112425,2.653341241478948,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-460-60XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,460.0,432.9,2.17,,,60.0,14.04,41.6,13.21,34.8,0.0047736,-0.10566400000000001,43.2,1.5203057904013577,14.054206992337537,1.801978404063068e-11,0.1546582296274207,152.8403409299239,9.283480657297051,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE460R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,460.0,437.9,1.98,,,18.0,15.93,36.0,15.16,30.4,0.0066906000000000005,-0.08532,43.1,1.2449662906776502,15.936715427968213,4.368001179789641e-12,0.10752657695268707,255.0691305473343,3.133444560190197,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE465R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,465.0,442.7,1.98,,,18.0,15.98,36.2,15.21,30.6,0.006711600000000001,-0.08579400000000001,43.1,1.2523873473237213,15.986510531541139,4.433484169163649e-12,0.10547431663958191,258.88509601859283,3.2331090078161844,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE470R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,470.0,447.6,1.98,,,18.0,16.03,36.4,15.23,30.9,0.006732600000000002,-0.086268,43.1,1.2628406026122145,16.037627198629586,4.810131276226175e-12,0.09587763961970401,201.50498757795182,3.913134803632209,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-510-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,510.0,479.2,2.58,,,72.0,13.36,48.2,12.68,40.2,0.0045424,-0.12242800000000001,43.2,1.7516340166097977,13.366297312279507,1.485087607048434e-11,0.2000024549279859,424.3132154891582,7.974408806520335,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-515-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,515.0,484.0,2.58,,,72.0,13.45,48.4,12.77,40.3,0.004573000000000001,-0.122936,43.2,1.7571754092504601,13.456075607010748,1.4560449194579217e-11,0.20550307938177176,454.9366738238042,7.740332967783866,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-520-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,520.0,488.8,2.58,,,72.0,13.52,48.5,12.84,40.5,0.0045968,-0.12319,43.2,1.7294428181797252,13.526626188340583,8.874274625248835e-12,0.20033350735247238,408.75823232453394,3.4458616189015197,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-525-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,525.0,493.6,2.58,,,72.0,13.59,48.7,12.9,40.7,0.0046206,-0.12369800000000002,43.2,1.7714744247308514,13.59618398607253,1.550294198488624e-11,0.19130080767342816,420.40489217635167,8.201842740047924,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-530-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,530.0,498.4,2.58,,,72.0,13.67,48.8,12.96,40.9,0.0046478000000000005,-0.12395199999999999,43.2,1.778635148602732,13.677092474721816,1.6438874067662317e-11,0.18019447490371374,347.3059128142679,8.672924719311515,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE530T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,530.0,499.5,2.56,,,24.0,13.72,49.3,12.83,41.3,0.0060368,-0.145928,43.2,1.8180481715324739,13.738327987342657,2.235904361774668e-11,0.18004156841659394,134.77586386459478,-4.572769553045986,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-535-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,535.0,503.2,2.58,,,72.0,13.72,49.1,13.02,41.1,0.004664800000000001,-0.12471400000000002,43.2,1.7876488714916992,13.726382027308068,1.6039817359947393e-11,0.18524850411369964,398.2448485435538,8.419267590629861,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE535T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,535.0,504.3,2.56,,,24.0,13.7,49.5,12.9,41.5,0.006027999999999999,-0.14651999999999998,43.2,1.819852387509457,13.712460074303884,2.071369835415015e-11,0.17889812279801656,196.70061625337433,-5.17726668097779,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-540-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,540.0,508.0,2.58,,,72.0,13.8,49.4,13.09,41.3,0.004692000000000001,-0.125476,43.2,1.7978593677929469,13.806897730832024,1.5952213848975056e-11,0.18973251944151584,379.5898755514848,8.321621686406258,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE540T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,540.0,509.2,2.56,,,24.0,13.86,49.6,12.97,41.6,0.0060983999999999995,-0.146816,43.2,1.8295840164895978,13.877557321988753,2.2762280123504526e-11,0.17506998387227873,138.20273891208012,-4.515253507455236,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-545-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,545.0,512.9,2.58,,,72.0,13.87,49.6,13.16,41.4,0.0047158,-0.125984,43.2,1.8034649526769482,13.876783497498478,1.5636974814751224e-11,0.19540718177189412,399.54280718423615,8.099960334918729,-0.343,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE545T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,545.0,514.0,2.56,,,24.0,13.93,49.8,13.04,41.8,0.0061292,-0.14740799999999998,43.2,1.8373825942112085,13.947118979403355,2.3027565409692244e-11,0.17208874752495867,140.03149400697393,-4.465576969963724,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-550-72XS,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,550.0,517.7,2.58,,,72.0,13.94,49.9,13.23,41.6,0.0047396,-0.126746,43.2,1.8130619959474517,13.946626152882528,1.541309462469945e-11,0.19998332139287878,420.7216220483757,7.9276238329371065,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE550T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,550.0,518.8,2.56,,,24.0,14.0,49.9,13.11,42.0,0.0061600000000000005,-0.147704,43.2,1.8434186208727996,14.016044856373147,2.3959210086092186e-11,0.16143789490308047,140.86324435632167,-4.197192010480979,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-550-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,555.0,519.9,2.84,,,60.0,17.3,40.1,16.47,33.4,0.00519,-0.10305700000000001,43.1,1.476425692648629,17.303682264770355,2.7602676188126624e-11,0.1287232776546725,604.7671476663115,9.914517998883472,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-555-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,555.0,519.9,2.84,,,60.0,17.38,40.2,16.55,33.5,0.005213999999999999,-0.103314,43.1,1.4803118311719714,17.383438819798855,2.784067071500098e-11,0.12730261733769188,643.3950008174245,9.94891812438806,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE555T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,555.0,523.6,2.56,,,24.0,14.07,50.1,13.18,42.1,0.006190800000000001,-0.14829599999999998,43.2,1.8489225494596921,14.086385378943328,2.3436520008894346e-11,0.16728063882332941,143.64261005816914,-4.40885800977868,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-560-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,560.0,524.7,2.84,,,60.0,17.46,40.4,16.63,33.7,0.005238,-0.10382799999999999,43.1,1.488245098700547,17.46321602267792,2.826540232711149e-11,0.1250615948290054,678.9676960862411,10.042049936367707,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE560T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,560.0,528.5,2.56,,,24.0,14.14,50.2,13.25,42.3,0.0062216,-0.148592,43.2,1.8549571920742298,14.155341626920412,2.437709356982237e-11,0.15676952304899283,144.4906120879602,-4.142357772561173,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-565-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,565.0,529.5,2.84,,,60.0,17.54,40.6,16.7,33.8,0.005262,-0.104342,43.1,1.4944104729707688,17.543609329828556,2.7774769127075578e-11,0.1296794892826419,630.1940838359689,9.846674578813305,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE565N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,565.0,537.2,2.56,,,24.0,13.48,52.1,12.93,43.7,0.0059312,-0.11722500000000001,43.1,1.7906204260756649,13.48000278524619,3.1147976880417236e-12,0.2066195609880179,999998.9852681692,7.079142420745837,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-570-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,570.0,534.3,2.84,,,60.0,17.61,40.8,16.78,34.0,0.005283,-0.10485599999999999,43.1,1.5019428813319067,17.61270098044574,2.7995314639571784e-11,0.1275447369862924,831.5731674783058,9.87813558871183,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE570N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,570.0,542.1,2.56,,,24.0,13.54,52.3,12.98,43.9,0.0059575999999999995,-0.117675,43.1,1.797601510471563,13.540002789030272,3.1341003221417646e-12,0.20598352511829685,999999.4188072613,7.094538116028009,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-575-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,575.0,539.1,2.84,,,60.0,17.69,40.9,16.86,34.1,0.005307000000000001,-0.105113,43.1,1.505830073660094,17.692469135548816,2.823324112781833e-11,0.12615562429135238,903.8357904316354,9.91219070756104,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE575N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,575.0,546.9,2.56,,,24.0,13.6,52.5,13.03,44.1,0.005984,-0.11812500000000001,43.1,1.8048454284357656,13.60015867486159,3.1661582806879885e-12,0.20468994934538157,17543.94758868488,7.146440160841605,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE575T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,575.0,541.9,2.77,,,26.0,13.72,53.5,12.83,44.8,0.0060368,-0.15836,43.2,1.9725071381664132,13.73846425004025,2.2229496876050825e-11,0.19703447376995956,146.40794975104802,-4.61786842472671,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-580-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,580.0,543.9,2.84,,,60.0,17.77,41.1,16.93,34.3,0.005331,-0.10562700000000001,43.1,1.5141835874045926,17.772959786742657,2.8853938737722213e-11,0.12393271302353302,744.068601813116,10.067670778546878,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE580N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,580.0,551.8,2.56,,,24.0,13.66,52.7,13.08,44.4,0.0060104,-0.11857500000000001,43.1,1.8146315436506428,13.660818185525365,3.3289176959906323e-12,0.19310286544225327,3223.9458080055792,7.556582738200181,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE580T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,580.0,546.8,2.77,,,26.0,13.79,53.6,12.9,45.0,0.006067599999999999,-0.158656,43.2,1.9785193153283263,13.807415817220518,2.3070626956287616e-11,0.1860795093626838,147.33942201252398,-4.370100044323994,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE585N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,585.0,556.6,2.56,,,24.0,13.72,52.9,13.13,44.6,0.0060368,-0.119025,43.1,1.8225563341933564,13.721322450739232,3.3968578383017182e-12,0.19023153201498985,1973.5908792166063,7.700505606457398,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE585T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,585.0,551.6,2.77,,,26.0,13.86,53.7,12.97,45.1,0.0060983999999999995,-0.158952,43.2,1.9822294730549308,13.877113520890008,2.3202474682012723e-11,0.1841087156093152,149.10706124040072,-4.366376792213057,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-590-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,590.0,553.5,2.84,,,60.0,17.93,41.5,17.08,34.6,0.005378999999999999,-0.10665500000000001,43.1,1.5282831771989496,17.933119758976677,2.8784108000428615e-11,0.12628567677875277,725.7939706259098,9.966648335217082,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE590G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,590.0,555.5,2.81,,,20.0,18.3,41.2,17.21,34.3,0.008601000000000001,-0.11906800000000001,43.4,1.5206342168984175,18.319482352200133,3.0749275821444896e-11,0.1261533478525915,118.49730746000847,-2.071731284908604,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE590N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,590.0,561.5,2.56,,,24.0,13.78,53.0,13.18,44.8,0.0060631999999999995,-0.11925000000000001,43.1,1.8286085238780447,13.78184875520147,3.5527165555647787e-12,0.17977918948704344,1340.013534005762,8.065521238843349,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE590T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,590.0,556.4,2.77,,,26.0,13.93,53.9,13.04,45.3,0.0061292,-0.159544,43.2,1.9900003411676543,13.946700073402374,2.3451231267361835e-11,0.18108806942044314,151.05064243235785,-4.32381458867606,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-595-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,595.0,558.4,2.84,,,60.0,18.0,41.6,17.15,34.7,0.005399999999999999,-0.10691200000000001,43.1,1.532189787034281,18.002917688707253,2.9016666358954873e-11,0.12499498091725023,771.1273835227912,10.002829117531636,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE595G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,595.0,560.3,2.81,,,20.0,18.34,41.4,17.25,34.5,0.0086198,-0.11964599999999999,43.4,1.5286819685912103,18.35908798218426,3.1184593314694807e-11,0.12426226496263286,119.39292117434624,-1.97754867178545,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE595N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,595.0,566.4,2.56,,,24.0,13.84,53.2,13.23,45.0,0.0060896,-0.11970000000000001,43.1,1.8365363633173541,13.842299584866717,3.62394457005008e-12,0.17697947702499753,1065.147085024721,8.207146521252707,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE595T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,595.0,561.3,2.77,,,26.0,14.0,54.0,13.11,45.4,0.0061600000000000005,-0.15984,43.2,1.9937138192080732,14.016406424833114,2.358465263778787e-11,0.17916414886277665,152.88511169717114,-4.319871836510794,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-600-60XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,600.0,563.2,2.84,,,60.0,18.08,41.8,17.22,34.8,0.005423999999999999,-0.107426,43.1,1.5383554659121705,18.08329568519889,2.8527731630180628e-11,0.12947359597011332,710.2871068299885,9.813302457658427,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE600G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,600.0,565.1,2.81,,,20.0,18.39,41.6,17.3,34.7,0.0086433,-0.120224,43.4,1.5367024018521869,18.408667191995253,3.1625286869143315e-11,0.12231585557906371,120.49956936918102,-1.887909353583001,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE600N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,600.0,571.2,2.56,,,24.0,13.9,53.4,13.28,45.2,0.006116,-0.12015,43.1,1.8444655281713358,13.902735297269915,3.696114288478612e-12,0.17420048855824413,885.23700769823,8.347892788074406,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE600T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,600.0,566.1,2.77,,,26.0,14.07,54.2,13.18,45.5,0.006190800000000001,-0.160432,43.2,1.9991918670282227,14.086697746549207,2.3110679879070298e-11,0.18492135258160058,155.820034331953,-4.517652284035946,-0.332,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE605G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,605.0,569.9,2.81,,,20.0,18.43,41.8,17.34,34.9,0.008662099999999999,-0.12080199999999999,43.4,1.5447476905925492,18.44828283410148,3.206352752123636e-11,0.12044449350196426,121.41400044436556,-1.795845301301945,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE605N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,605.0,576.1,2.56,,,24.0,13.96,53.6,13.33,45.4,0.0061424,-0.12060000000000001,43.1,1.8523961148259946,13.963156129592962,3.769236585332359e-12,0.1714419762620931,758.3117014300051,8.487783013582488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE605R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,605.0,575.5,2.68,,,22.0,15.71,48.3,14.94,40.5,0.006598200000000001,-0.11447099999999999,43.1,1.665372547946536,15.71784709474558,3.9515991332873535e-12,0.1680084986820972,336.3555054173159,2.4018693528497352,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE605T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,605.0,570.9,2.77,,,26.0,14.14,54.3,13.25,45.7,0.0062216,-0.160728,43.2,2.0052027398500067,14.15572012547372,2.3970313164413455e-11,0.17432324305548785,156.8009521296189,-4.273438969974505,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE610G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,610.0,574.8,2.81,,,20.0,18.48,42.0,17.38,35.1,0.008685600000000002,-0.12137999999999999,43.4,1.553209471062034,18.498542408918333,3.273732382285182e-11,0.11848439302886596,118.0856069483094,-1.6497681896032172,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE610N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,610.0,581.0,2.56,,,24.0,14.02,53.8,13.38,45.6,0.0061687999999999995,-0.12105,43.1,1.8603280483494393,14.023562226221152,3.843312898009671e-12,0.1687037230431541,663.9741860106104,8.62681653995585,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE610R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,610.0,580.4,2.68,,,22.0,15.75,48.5,14.98,40.7,0.006615,-0.11494499999999999,43.1,1.6727906028044455,15.757674190147704,3.998009612995591e-12,0.16583407952854057,340.3468727135544,2.478869399872595,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE610T,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,610.0,575.8,2.77,,,26.0,14.21,54.4,13.32,45.8,0.0062524,-0.161024,43.2,2.0089214224195264,14.225438188992058,2.410599295399962e-11,0.1724638745760692,158.74346842897313,-4.269108652709106,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-615-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,615.0,576.2,3.12,,,66.0,17.44,44.4,16.61,37.0,0.0052320000000000005,-0.114108,43.1,1.6348383198428689,17.44324631731371,2.7880785274903407e-11,0.14012776662125817,752.8001975488323,9.930246390694636,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE615N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,615.0,584.8,2.77,,,26.0,13.65,56.2,13.01,47.3,0.006006,-0.12645,43.1,1.9381642214222508,13.654703907111815,3.461896534972871e-12,0.20997547342060655,609.3158852207074,7.934651930428964,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE615R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,615.0,585.2,2.68,,,22.0,15.79,48.8,15.02,41.0,0.0066318,-0.115656,43.1,1.683964667678295,15.797475360035463,4.065826524776967e-12,0.16279752849697673,343.8727991438359,2.5997088924280756,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE-620-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,620.0,581.0,3.12,,,66.0,17.51,44.6,16.68,37.2,0.005253,-0.114622,43.1,1.642777352341794,17.51305561635254,2.8264186528088347e-11,0.13791454165825592,790.3098485829132,10.015496323381676,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE620N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,620.0,589.7,2.77,,,26.0,13.69,56.5,13.05,47.5,0.0060236,-0.12712500000000002,43.1,1.9474004273564471,13.694627367677361,3.4160408781362563e-12,0.2150502559771934,636.223057452169,7.788493060965829,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE620R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,620.0,590.1,2.68,,,22.0,15.83,49.0,15.06,41.2,0.0066486,-0.11613,43.1,1.6913806628780814,15.837307518314354,4.112553529155163e-12,0.16064957955154444,348.0090968705184,2.6748260338784022,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-625-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,625.0,585.8,3.12,,,66.0,17.58,44.8,16.75,37.3,0.005273999999999999,-0.11513599999999999,43.1,1.6485284616731741,17.58275601062467,2.764327347629802e-11,0.14256618953420713,909.3989503835128,9.780905686350842,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE625N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,625.0,594.5,2.77,,,26.0,13.73,56.7,13.09,47.8,0.0060412,-0.12757500000000002,43.1,1.9566483177646796,13.7344375974963,3.5474634925366655e-12,0.20377405279117067,630.4802892017698,8.099721782690692,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE625R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,625.0,595.0,2.68,,,22.0,15.87,49.2,15.1,41.4,0.006665400000000001,-0.116604,43.1,1.6987958951781175,15.877142104862942,4.1594167966110695e-12,0.15851342677774893,352.2222279040189,2.749225516466034,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-630-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,630.0,590.6,3.12,,,66.0,17.65,44.9,16.82,37.5,0.005294999999999999,-0.11539300000000001,43.1,1.6546078677647462,17.652671754253287,2.8867018755256677e-11,0.1343686473346302,887.6589995308891,10.131102456208191,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE630N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,630.0,599.4,2.77,,,26.0,13.77,56.9,13.13,48.0,0.006058799999999999,-0.128025,43.1,1.9640163365285295,13.774313254979292,3.582744005656822e-12,0.2012007917654354,642.3304516789796,8.161717297960164,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE630R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,630.0,599.8,2.68,,,22.0,15.91,49.4,15.14,41.6,0.0066822,-0.11707799999999999,43.1,1.7062103750994262,15.916979103172057,4.2064146247823375e-12,0.15638897107933605,356.5140780790337,2.822917471469596,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-635-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,635.0,595.5,3.12,,,66.0,17.72,45.1,16.89,37.6,0.0053159999999999995,-0.11590700000000001,43.1,1.6603604751518073,17.722371497658333,2.8236611309377384e-11,0.13899537035643653,1038.5833101657759,9.89776943059728,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE635N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,635.0,604.3,2.77,,,26.0,13.81,57.1,13.17,48.2,0.0060764,-0.128475,43.1,1.9713837437927155,13.814191036812618,3.6181248715152003e-12,0.19864354714129037,654.5557859734351,8.223200231477934,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE635R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,635.0,604.7,2.68,,,22.0,15.95,49.6,15.18,41.8,0.006699000000000001,-0.117552,43.1,1.7136241082886654,15.956818493304853,4.253545014748164e-12,0.15427611513801762,360.88677191455844,2.895911235303039,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-640-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,640.0,600.3,3.12,,,66.0,17.79,45.3,16.69,37.7,0.005337,-0.116421,43.1,1.6789506063686925,17.811709603990696,3.337334676672715e-11,0.14275711129216478,116.98274298327979,11.432628830222919,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE640N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,640.0,609.1,2.77,,,26.0,13.85,57.3,13.21,48.5,0.0060940000000000005,-0.12892499999999998,43.1,1.980623620977026,13.85400216402484,3.754366508030777e-12,0.18752669757940515,648.9601010315081,8.528633118117629,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE640R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,640.0,609.6,2.68,,,22.0,15.99,49.9,15.22,42.1,0.006715800000000001,-0.118263,43.1,1.724792245056884,15.996633048789517,4.322310675777407e-12,0.1513131186413911,364.76390361614665,3.010762570157835,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-645-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,645.0,605.1,3.12,,,66.0,17.87,45.5,17.03,37.9,0.005361,-0.11693500000000001,43.1,1.674492089727485,17.87255759301031,2.8199011869182357e-11,0.14129671274056269,987.2455662215474,9.811513787120763,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE645N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,645.0,614.0,2.77,,,26.0,13.89,57.6,13.25,48.7,0.006111599999999999,-0.12960000000000002,43.1,1.9898608754775595,13.893943341879169,3.704679873974037e-12,0.19258980480740165,678.3769902823667,8.382304212630302,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE645R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,645.0,614.5,2.68,,,22.0,16.03,50.1,15.26,42.3,0.006732600000000002,-0.118737,43.1,1.732204138533144,16.036477438590495,4.369739111717279e-12,0.14922562392070376,369.2951642484751,3.0820249349207627,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-650-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,650.0,609.9,3.12,,,66.0,17.94,45.6,17.09,38.0,0.005382,-0.117192,43.1,1.6788475475231517,17.94306870610902,2.860620602769216e-11,0.13991500535174475,817.9588373652746,9.906224566606431,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE650G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,650.0,612.0,3.08,,,22.0,18.21,45.4,17.29,37.6,0.0085587,-0.131206,43.4,1.663384939563966,18.21757201325662,2.5352607649423487e-11,0.15327374779327774,368.6093636663368,-3.5939721225767802,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE650N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,650.0,618.9,2.77,,,26.0,13.93,57.8,13.29,48.9,0.0061292,-0.13005,43.1,1.9972262750636725,13.933827740080345,3.740390434610998e-12,0.19008286835916038,691.7539897412036,8.442025390326942,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE650R,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,650.0,619.3,2.68,,,22.0,16.07,50.3,15.3,42.5,0.006749400000000001,-0.119211,43.1,1.7396153223997144,16.076324174200263,4.417294522078489e-12,0.14714942621761973,373.9130523830637,3.1526232223684194,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-655-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,655.0,614.7,3.12,,,66.0,18.01,45.8,17.16,38.2,0.005403,-0.11770599999999999,43.1,1.6867865679006955,18.012882559953823,2.898938947855766e-11,0.1377645709904055,860.7418593584122,9.989336527721,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE655G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,655.0,616.8,3.08,,,22.0,18.26,45.6,17.33,37.8,0.0085822,-0.13178399999999998,43.4,1.6718366406100362,18.26816597403599,2.5877667135926056e-11,0.1512336510155692,338.17478383716303,-3.4528424793856085,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE655N,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,655.0,623.7,2.77,,,26.0,13.97,58.0,13.33,49.1,0.006146800000000001,-0.1305,43.1,2.0045910913767324,13.973714178655404,3.776197321561961e-12,0.18759133844248946,705.5801882681326,8.501260948619159,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +KOSOL ENERGIE PVT LTD KE-660-66XU,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,660.0,619.5,3.12,,,66.0,18.08,46.0,17.22,38.3,0.005423999999999999,-0.11822,43.1,1.6930004023734044,18.083299229779808,2.8561087090735332e-11,0.1422598180603076,779.5933491303455,9.823718126897353,-0.359,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE660G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,660.0,621.7,3.08,,,22.0,18.31,45.8,17.37,38.0,0.008605699999999999,-0.13236199999999998,43.4,1.6802910605838406,18.31873742280525,2.6409786161050997e-11,0.14920247450305904,312.66626361326337,-3.312620177644776,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE665G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,665.0,626.5,3.08,,,22.0,18.36,46.0,17.41,38.2,0.0086292,-0.13294,43.4,1.6887481563521691,18.369286727662054,2.6948993299421033e-11,0.1471801498522875,290.9773690610875,-3.1732708961004583,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE670G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,670.0,631.3,3.08,,,22.0,18.41,46.2,17.45,38.4,0.008652700000000001,-0.133518,43.4,1.6972079554281438,18.419814248464768,2.749533988942367e-11,0.14516662694276364,272.30996246768063,-3.034823261070504,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE675G,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,675.0,636.2,3.08,,,22.0,18.46,46.4,17.49,38.6,0.0086762,-0.134096,43.4,1.7056703901125958,18.470320336262585,2.804884550126744e-11,0.14316183237870644,256.07377370542065,-2.8972221081447405,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +KOSOL ENERGIE PVT LTD KE700U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,700.0,666.2,3.08,,,22.0,18.1,48.6,17.44,40.1,0.007602000000000001,-0.11421,43.1,1.6583389195391955,18.100281718098707,3.3881825583411003e-12,0.18910792938696847,12149.92486547816,0.7494332954931694,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE705U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,705.0,671.1,3.08,,,22.0,18.14,48.8,17.48,40.3,0.007618800000000001,-0.11467999999999999,43.1,1.665790796007966,18.140283766092125,3.433348353808374e-12,0.18718984361529073,11966.278048175382,0.8417296499744439,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE710U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,710.0,675.9,3.08,,,22.0,18.18,49.0,17.52,40.5,0.0076356,-0.11514999999999999,43.1,1.6732429177224937,18.180285785009517,3.4787720349102765e-12,0.1852807865446611,11786.499529400582,0.9333085925375249,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +KOSOL ENERGIE PVT LTD KE715U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,715.0,680.8,3.08,,,22.0,18.22,49.2,17.56,40.7,0.0076524,-0.11562,43.1,1.6808201880364444,18.220003557703986,3.5328830541991726e-12,0.16645005709509922,852441.6978422353,1.0433465208637744,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +KOSOL ENERGIE PVT LTD KE720U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,720.0,685.7,3.08,,,22.0,18.26,49.4,17.6,40.9,0.007669200000000001,-0.11609,43.1,1.6882707184781267,18.26000347495252,3.578776517898373e-12,0.1644568187721056,864183.487375023,1.133157908322184,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +KOSOL ENERGIE PVT LTD KE725U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,725.0,690.6,3.08,,,22.0,18.3,49.6,17.64,41.1,0.007686000000000002,-0.11656000000000001,43.1,1.695721520685675,18.300003481374315,3.624924189874627e-12,0.16247101012944504,854040.3574110665,1.2222843166213078,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +KOSOL ENERGIE PVT LTD KE730U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,730.0,695.4,3.08,,,22.0,18.34,49.7,17.68,41.3,0.007702800000000001,-0.11679500000000001,43.1,1.701101679942326,18.340003328401924,3.7574556980109125e-12,0.1552261588924274,855323.8565942126,1.505637305147768,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +KOSOL ENERGIE PVT LTD KE735U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,735.0,700.3,3.08,,,22.0,18.38,49.9,17.72,41.5,0.0077196,-0.117265,43.1,1.7085525212205224,18.38000329055536,3.804834220834616e-12,0.15326772450181528,856109.0902663688,1.5927424798767993,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +KOSOL ENERGIE PVT LTD KE740U,KOSOL ENERGIE PVT LTD,Mono-c-Si,0,740.0,705.2,3.08,,,22.0,18.42,50.1,17.76,41.7,0.007736400000000002,-0.11773499999999999,43.1,1.7160035393172297,18.420003252774173,3.852457164441664e-12,0.15131670811795805,856889.215965454,1.6791779269870923,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +La Solar LLC LS390BL,La Solar LLC,Mono-c-Si,0,390.0,367.6,1.96,,,18.0,13.59,36.7,12.78,30.53,0.005585489999999999,-0.10910910000000001,43.2,1.3312843610460396,13.605703531058943,1.4212854220383336e-11,0.15740988583141988,136.22416182316692,-8.335123433393974,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS395BL,La Solar LLC,Mono-c-Si,0,395.0,372.4,1.96,,,18.0,13.66,36.9,12.87,30.7,0.005614259999999999,-0.1097037,43.2,1.3708131980409617,13.672492114845912,2.7430307759086816e-11,0.15145683052104028,165.61649860275142,-3.367183609719723,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS400BL,La Solar LLC,Mono-c-Si,0,400.0,377.3,1.96,,,18.0,13.73,37.1,12.96,30.87,0.00564303,-0.1102983,43.2,1.3435026367672311,13.742183587220781,1.3759559024112687e-11,0.15704810618175588,176.98157927225998,-8.666551818129799,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS405BL,La Solar LLC,Mono-c-Si,0,405.0,382.1,1.96,,,18.0,13.81,37.3,13.06,30.87,0.005675909999999999,-0.1108929,43.2,1.3458163862622134,13.82097290459411,1.2542475069072518e-11,0.1716930528395709,216.0850897615173,-9.403895914666583,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS410BL,La Solar LLC,Mono-c-Si,0,410.0,386.9,1.96,,,18.0,13.88,37.5,13.15,31.2,0.00570468,-0.1114875,43.2,1.355503119465306,13.88868013529081,1.328065430425938e-11,0.1574478650038783,251.7675554730226,-9.023773549054228,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS430BL,La Solar LLC,Mono-c-Si,0,430.0,401.9,2.19,,,72.0,11.24,48.8,10.66,40.3,0.0057323999999999995,-0.1426912,44.1,1.8270098304761477,11.244722682035913,2.8046317108978286e-11,0.2709679242636031,644.9046374874205,-0.16043843320547385,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS430HC,La Solar LLC,Mono-c-Si,0,430.0,401.3,2.209184,,,72.0,11.24,48.8,10.66,40.3,0.0054851200000000004,-0.1826584,44.1,1.8573637525005817,11.244018141470331,4.343137909148779e-11,0.2647657546374665,740.6327605967508,-19.293132121333798,-0.3583,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS435BL,La Solar LLC,Mono-c-Si,0,435.0,406.7,2.19,,,72.0,11.31,49.0,10.74,40.5,0.0057681,-0.143276,44.1,1.8341880401595205,11.31364832317388,2.813350374005568e-11,0.26673132075770756,826.8816086792107,-0.19017306619047883,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS435HC,La Solar LLC,Mono-c-Si,0,435.0,406.1,2.209184,,,72.0,11.31,49.0,10.74,40.5,0.0055192800000000005,-0.18340700000000001,44.1,1.8646463210568516,11.312972499645696,4.3560496873421383e-11,0.26055195035638024,991.3685705997638,-19.31781437520321,-0.3583,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS440BL,La Solar LLC,Mono-c-Si,0,440.0,411.5,2.19,,,72.0,11.39,49.2,10.82,40.7,0.0058089,-0.1438608,44.1,1.8421577790714154,11.393361769303036,2.854181909316439e-11,0.2622652637073716,888.5801455575842,-0.13182414914114768,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS440HC,La Solar LLC,Mono-c-Si,0,440.0,410.9,2.209184,,,72.0,11.39,49.2,10.82,40.7,0.00555832,-0.18415560000000003,44.1,1.9860469807249723,11.390008778538087,1.9852509982862842e-10,0.23358031694640596,303085.69728535577,-8.895464035617946,-0.3583,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS445BL,La Solar LLC,Mono-c-Si,0,445.0,416.3,2.19,,,72.0,11.46,49.4,10.9,40.8,0.0058446,-0.1444456,44.1,1.846996439201968,11.462253773260834,2.7682354183309376e-11,0.2687302048831564,1366.4409751422545,-0.43360323269852685,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS445HC,La Solar LLC,Mono-c-Si,0,445.0,415.7,2.209184,,,72.0,11.46,49.4,10.9,40.8,0.00559248,-0.18490420000000002,44.1,1.9574606342593917,11.460009479417735,1.2559870449838512e-10,0.2468440997157522,298431.29609540687,-12.23515426783355,-0.3583,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS450BL,La Solar LLC,Mono-c-Si,0,450.0,421.1,2.19,,,72.0,11.53,49.6,10.98,41.0,0.0058803,-0.1450304,44.1,1.8541952859902189,11.531217775658973,2.7777093448479795e-11,0.2645952209041589,2505.2095715362893,-0.4596487576241359,-0.3517,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS450HC,La Solar LLC,Mono-c-Si,0,450.0,420.5,2.209184,,,72.0,11.53,49.6,10.98,41.0,0.0056266400000000005,-0.18565280000000003,44.1,1.9144947183384837,11.53000580767296,6.460851691132027e-11,0.2526710193007977,501648.8596910484,-16.851493822120606,-0.3583,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS530BF,La Solar LLC,Mono-c-Si,1,530.0,498.7,2.58,,,72.0,13.6,49.3,12.92,41.03,0.004950400000000001,-0.12813070000000001,43.0,1.7966363796580582,13.605392152562779,1.6352354962257348e-11,0.20744524095562394,523.2150382849163,6.147081349755471,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS530BL,La Solar LLC,Mono-c-Si,0,530.0,498.3,2.58,,,72.0,13.6,49.3,12.92,41.03,0.0048688,-0.1274405,43.3,1.7911073562147317,13.605537209828965,1.502209082094783e-11,0.2083965153668902,511.84490515684547,6.001072872579426,-0.3418,N,2025.7.3,6/23/2025,4.0,bootstrapping +La Solar LLC SLR530BF,La Solar LLC,Mono-c-Si,1,530.0,498.7,2.58,,,72.0,13.6,49.3,12.92,41.03,0.004950400000000001,-0.12813070000000001,43.0,1.7966363796580582,13.605392152562779,1.6352354962257348e-11,0.20744524095562394,523.2150382849163,6.147081349755471,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR530BL,La Solar LLC,Mono-c-Si,0,530.0,498.3,2.58,,,72.0,13.6,49.3,12.92,41.03,0.0048688,-0.1274405,43.3,1.7911073562147317,13.605537209828965,1.502209082094783e-11,0.2083965153668902,511.84490515684547,6.001072872579426,-0.3418,N,2025.7.3,6/23/2025,4.0,bootstrapping +La Solar LLC LS535BF,La Solar LLC,Mono-c-Si,1,535.0,503.5,2.58,,,72.0,13.7,49.4,12.96,41.29,0.0049868,-0.12839060000000002,43.0,1.8077419890384978,13.709053541044623,1.8349199189279665e-11,0.1904404858251059,288.17836670705304,7.10136769939176,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS535BL,La Solar LLC,Mono-c-Si,0,535.0,503.2,2.58,,,72.0,13.7,49.4,12.96,41.29,0.004904599999999999,-0.127699,43.3,1.8021550123054604,13.709209579471445,1.685632660079572e-11,0.19140266965649694,284.7270707448977,6.954589285699639,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR535BF,La Solar LLC,Mono-c-Si,1,535.0,503.5,2.58,,,72.0,13.7,49.4,12.96,41.29,0.0049868,-0.12839060000000002,43.0,1.8077419890384978,13.709053541044623,1.8349199189279665e-11,0.1904404858251059,288.17836670705304,7.10136769939176,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR535BL,La Solar LLC,Mono-c-Si,0,535.0,503.2,2.58,,,72.0,13.7,49.4,12.96,41.29,0.004904599999999999,-0.127699,43.3,1.8021550123054604,13.709209579471445,1.685632660079572e-11,0.19140266965649694,284.7270707448977,6.954589285699639,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS540BF,La Solar LLC,Mono-c-Si,1,540.0,508.3,2.58,,,72.0,13.81,49.5,13.0,41.55,0.00502684,-0.1286505,43.0,1.8195670698537263,13.8225785868581,2.0781263443179077e-11,0.17331453297496618,190.2816062120971,8.141633712728007,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS540BL,La Solar LLC,Mono-c-Si,0,540.0,508.0,2.58,,,72.0,13.81,49.5,13.0,41.55,0.00494398,-0.1279575,43.3,1.8139179605164293,13.822749565309946,1.909047772374483e-11,0.17428848977713135,188.784793842536,7.994061934975628,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR540BF,La Solar LLC,Mono-c-Si,1,540.0,508.3,2.58,,,72.0,13.81,49.5,13.0,41.55,0.00502684,-0.1286505,43.0,1.8195670698537263,13.8225785868581,2.0781263443179077e-11,0.17331453297496618,190.2816062120971,8.141633712728007,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR540BL,La Solar LLC,Mono-c-Si,0,540.0,508.0,2.58,,,72.0,13.81,49.5,13.0,41.55,0.00494398,-0.1279575,43.3,1.8139179605164293,13.822749565309946,1.909047772374483e-11,0.17428848977713135,188.784793842536,7.994061934975628,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS545BF,La Solar LLC,Mono-c-Si,1,545.0,513.1,2.58,,,72.0,13.92,49.6,13.04,41.81,0.00506688,-0.12891040000000004,43.0,1.831491626153011,13.9352606883543,2.353300995869818e-11,0.15626392754247137,142.53576445690246,9.19030245715835,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS545BL,La Solar LLC,Mono-c-Si,0,545.0,512.8,2.58,,,72.0,13.92,49.6,13.04,41.81,0.004983359999999999,-0.12821600000000002,43.3,1.8257800920650342,13.935447330964054,2.16184708741197e-11,0.1572496941204198,141.70187432426658,9.041974184281681,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR545BF,La Solar LLC,Mono-c-Si,1,545.0,513.1,2.58,,,72.0,13.92,49.6,13.04,41.81,0.00506688,-0.12891040000000004,43.0,1.831491626153011,13.9352606883543,2.353300995869818e-11,0.15626392754247137,142.53576445690246,9.19030245715835,-0.3437,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR545BL,La Solar LLC,Mono-c-Si,0,545.0,512.8,2.58,,,72.0,13.92,49.6,13.04,41.81,0.004983359999999999,-0.12821600000000002,43.3,1.8257800920650342,13.935447330964054,2.16184708741197e-11,0.1572496941204198,141.70187432426658,9.041974184281681,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC LS550BF,La Solar LLC,Mono-c-Si,1,550.0,518.0,2.58,,,72.0,14.02,49.7,13.08,42.07,0.00510328,-0.12917030000000002,43.0,1.8428533939940492,14.036635898758657,2.6392082165551716e-11,0.13949784579611824,117.56261751301389,10.165148991308259,-0.3437,N,2025.7.3,6/23/2025,2.0,first_pass +La Solar LLC LS550BL,La Solar LLC,Mono-c-Si,0,550.0,517.6,2.58,,,72.0,14.02,49.7,13.08,42.07,0.005019159999999999,-0.12847450000000002,43.3,1.8370831631676943,14.036835366388262,2.4245237977568323e-11,0.14049459872839792,116.9997869192311,10.016140651356366,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +La Solar LLC SLR550BF,La Solar LLC,Mono-c-Si,1,550.0,518.0,2.58,,,72.0,14.02,49.7,13.08,42.07,0.00510328,-0.12917030000000002,43.0,1.8428533939940492,14.036635898758657,2.6392082165551716e-11,0.13949784579611824,117.56261751301389,10.165148991308259,-0.3437,N,2025.7.3,6/23/2025,2.0,first_pass +La Solar LLC SLR550BL,La Solar LLC,Mono-c-Si,0,550.0,517.6,2.58,,,72.0,14.02,49.7,13.08,42.07,0.005019159999999999,-0.12847450000000002,43.3,1.8370831631676943,14.036835366388262,2.4245237977568323e-11,0.14049459872839792,116.9997869192311,10.016140651356366,-0.3418,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-390W,Leapton Energy Co Ltd,Mono-c-Si,0,390.0,361.3,1.94,,,54.0,13.5,36.54,12.82,30.42,0.005184,-0.09869454,44.82,1.3662464775232095,13.504550278707663,3.2559322324720953e-11,0.14812719611134656,439.4713650542237,8.008261067077404,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-395W,Leapton Energy Co Ltd,Mono-c-Si,0,395.0,366.1,1.94,,,54.0,13.55,36.74,12.88,30.62,0.0052032,-0.09923474,44.82,1.3730622492533522,13.553705774384762,3.229353761696259e-11,0.14558896956264233,532.3396375174889,7.900669196055631,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-400W,Leapton Energy Co Ltd,Mono-c-Si,0,400.0,370.9,1.94,,,54.0,13.6,36.94,12.94,30.92,0.0052224,-0.09977494,44.82,1.4192541755487644,13.601919007838447,6.738861123266336e-11,0.12788798493978484,906.3413556642541,14.454901108069507,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-405W,Leapton Energy Co Ltd,Mono-c-Si,0,405.0,375.6,1.94,,,54.0,13.65,37.14,13.0,31.12,0.0052416,-0.10031514000000001,44.82,1.4270363524333418,13.651209850942823,6.782675090884398e-11,0.12530338389498566,1413.7207843537603,14.476720098330269,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-410W,Leapton Energy Co Ltd,Mono-c-Si,0,410.0,380.4,1.94,,,54.0,13.7,37.34,13.06,31.32,0.005260799999999999,-0.10085534000000002,44.82,1.4348156068577091,13.700531885747974,6.826132711687759e-11,0.1227438893715777,3161.5663613464767,14.497814531636466,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-415W,Leapton Energy Co Ltd,Mono-c-Si,0,415.0,385.2,1.94,,,54.0,13.75,37.54,13.12,31.62,0.00528,-0.10139554,44.82,1.4449356505198212,13.750070874297169,7.163208373920687e-11,0.11143140346582181,21618.21921222765,14.906588651367528,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-420W,Leapton Energy Co Ltd,Mono-c-Si,0,420.0,390.0,1.94,,,54.0,13.8,37.74,13.24,31.72,0.0052992,-0.10193574000000001,44.82,1.3944820172172545,13.800003255465867,2.4333944165094933e-11,0.1269803922527127,538283.1239984465,5.284889343402872,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-54-MH-425W,Leapton Energy Co Ltd,Mono-c-Si,0,425.0,394.8,1.94,,,54.0,13.85,37.94,13.31,31.92,0.0053184,-0.10247593999999999,44.82,1.4640139306604918,13.850001321603541,7.703422104870564e-11,0.09541443897328288,999999.8894590725,15.51340107996091,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-535W,Leapton Energy Co Ltd,Mono-c-Si,0,535.0,502.0,2.56,,,72.0,13.81,49.2,13.05,41.0,0.00723644,-0.12423000000000001,45.27,1.776757264519378,13.82113546397285,1.283346297775168e-11,0.202607566567602,251.27022188114228,6.818454271433291,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-540W,Leapton Energy Co Ltd,Mono-c-Si,0,540.0,506.8,2.56,,,72.0,13.87,49.4,13.11,41.2,0.00726788,-0.124735,45.27,1.7844809338624503,13.88083669299501,1.299267389623268e-11,0.19965627614489845,255.54221766672396,6.887385922348205,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-545W,Leapton Energy Co Ltd,Mono-c-Si,0,545.0,511.7,2.56,,,72.0,13.93,49.6,13.17,41.4,0.007299320000000001,-0.12524000000000002,45.27,1.7922039638823077,13.940543499759668,1.3152579407128386e-11,0.19673235360041536,259.92144655650975,6.955676253068071,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-550W,Leapton Energy Co Ltd,Mono-c-Si,0,550.0,516.5,2.56,,,72.0,13.99,49.8,13.23,41.6,0.00733076,-0.125745,45.27,1.7999263623029316,14.00025580247388,1.3313174000591843e-11,0.19383541989266437,264.4120296012637,7.023333329595485,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-555W,Leapton Energy Co Ltd,Mono-c-Si,0,555.0,521.3,2.56,,,72.0,14.05,50.0,13.29,41.8,0.007362200000000001,-0.12625,45.27,1.8076481279114551,14.059973516109395,1.3474450501237887e-11,0.1909651040256446,269.0184195091684,7.090364578535593,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-560W,Leapton Energy Co Ltd,Mono-c-Si,0,560.0,526.1,2.56,,,72.0,14.11,50.2,13.33,42.0,0.007393640000000001,-0.126755,45.27,1.8166503182647142,14.121054573525075,1.388052059392256e-11,0.18800238529621435,239.9652651829406,7.318646496073761,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-565W,Leapton Energy Co Ltd,Mono-c-Si,0,565.0,530.9,2.56,,,72.0,14.17,50.4,13.39,42.2,0.00742508,-0.12726,45.27,1.8243712463513395,14.180761389787024,1.404502244698031e-11,0.18518030214637812,243.83513195045842,7.383872285469481,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Leapton Energy Co Ltd LP182*182-M-72-MH-570W,Leapton Energy Co Ltd,Mono-c-Si,0,570.0,535.8,2.56,,,72.0,14.23,50.6,13.44,42.4,0.007456520000000001,-0.127765,45.27,1.8327351224732626,14.241130580125764,1.4336170857796651e-11,0.18231962814077743,233.08832916748935,7.5291841043515975,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-390-108M-B,LENERGY POWER INC,Mono-c-Si,0,390.0,364.4,1.94,,,54.0,13.55,36.7,12.73,30.6,0.0055555000000000005,-0.10055800000000002,43.5,1.361603539327135,13.564786540904116,2.6170624306297123e-11,0.14658687425202563,134.3283848871843,4.582796908503118,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-390-108M-W,LENERGY POWER INC,Mono-c-Si,0,390.0,364.4,1.94,,,54.0,13.55,36.7,12.73,30.6,0.0055555000000000005,-0.10055800000000002,43.5,1.361603539327135,13.564786540904116,2.6170624306297123e-11,0.14658687425202563,134.3283848871843,4.582796908503118,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-395-108M-B,LENERGY POWER INC,Mono-c-Si,0,395.0,369.2,1.94,,,54.0,13.62,36.9,12.79,30.9,0.0055842,-0.101106,43.5,1.3655196704183559,13.634530584504319,2.4519241976571904e-11,0.13580875715278443,127.29806435833122,3.9936891881586893,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-395-108M-W,LENERGY POWER INC,Mono-c-Si,0,395.0,369.2,1.94,,,54.0,13.62,36.9,12.79,30.9,0.0055842,-0.101106,43.5,1.3655196704183559,13.634530584504319,2.4519241976571904e-11,0.13580875715278443,127.29806435833122,3.9936891881586893,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-400-108M-B,LENERGY POWER INC,Mono-c-Si,0,400.0,374.0,1.94,,,54.0,13.7,37.1,12.86,31.1,0.005617,-0.10165400000000001,43.5,1.4134784547353774,13.713034196504074,5.359303465681408e-11,0.1259760051967862,132.411088426298,10.72002128733314,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-400-108M-W,LENERGY POWER INC,Mono-c-Si,0,400.0,374.0,1.94,,,54.0,13.7,37.1,12.86,31.1,0.005617,-0.10165400000000001,43.5,1.4134784547353774,13.713034196504074,5.359303465681408e-11,0.1259760051967862,132.411088426298,10.72002128733314,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-405-108M-B,LENERGY POWER INC,Mono-c-Si,0,405.0,378.8,1.94,,,54.0,13.77,37.4,12.94,31.3,0.0056457,-0.10247600000000001,43.5,1.422897736134163,13.782611771905572,5.198165210597448e-11,0.13104595069456157,143.08082746236533,10.396720652463058,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-405-108M-W,LENERGY POWER INC,Mono-c-Si,0,405.0,378.8,1.94,,,54.0,13.77,37.4,12.94,31.3,0.0056457,-0.10247600000000001,43.5,1.422897736134163,13.782611771905572,5.198165210597448e-11,0.13104595069456157,143.08082746236533,10.396720652463058,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-410-108M-B,LENERGY POWER INC,Mono-c-Si,0,410.0,383.6,1.94,,,54.0,13.85,37.6,13.02,31.5,0.0056785,-0.103024,43.5,1.4310116274533151,13.86216753677909,5.278849707914693e-11,0.12813037132865734,145.84756933862639,10.481115987981289,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-410-108M-W,LENERGY POWER INC,Mono-c-Si,0,410.0,383.6,1.94,,,54.0,13.85,37.6,13.02,31.5,0.0056785,-0.103024,43.5,1.4310116274533151,13.86216753677909,5.278849707914693e-11,0.12813037132865734,145.84756933862639,10.481115987981289,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-420-108M-B,LENERGY POWER INC,Mono-c-Si,0,420.0,393.2,1.94,,,54.0,13.92,37.8,13.1,32.0,0.0057072,-0.10357200000000001,43.5,1.4456618235209875,13.929190880856607,6.031342154260732e-11,0.09902825153925882,149.982822550165,11.628887435797424,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-420-108M-W,LENERGY POWER INC,Mono-c-Si,0,420.0,393.2,1.94,,,54.0,13.92,37.8,13.1,32.0,0.0057072,-0.10357200000000001,43.5,1.4456618235209875,13.929190880856607,6.031342154260732e-11,0.09902825153925882,149.982822550165,11.628887435797424,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-440-120M-B,LENERGY POWER INC,Mono-c-Si,0,440.0,411.3,2.15,,,60.0,13.54,41.2,12.74,34.5,0.0055514,-0.11288800000000002,43.5,1.566941346845056,13.55129469131013,5.0734903331238417e-11,0.14515198085687028,174.00722719641217,10.325153637140298,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-440-120M-W,LENERGY POWER INC,Mono-c-Si,0,440.0,411.3,2.15,,,60.0,13.54,41.2,12.74,34.5,0.0055514,-0.11288800000000002,43.5,1.566941346845056,13.55129469131013,5.0734903331238417e-11,0.14515198085687028,174.00722719641217,10.325153637140298,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-445-120M-B,LENERGY POWER INC,Mono-c-Si,0,445.0,416.1,2.15,,,60.0,13.6,41.4,12.8,34.8,0.005576,-0.11343600000000001,43.5,1.5774511208634077,13.610394831057391,5.3484426630994324e-11,0.13330744216293816,174.41180366803044,10.75664938478268,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-445-120M-W,LENERGY POWER INC,Mono-c-Si,0,445.0,416.1,2.15,,,60.0,13.6,41.4,12.8,34.8,0.005576,-0.11343600000000001,43.5,1.5774511208634077,13.610394831057391,5.3484426630994324e-11,0.13330744216293816,174.41180366803044,10.75664938478268,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-450-120M-B,LENERGY POWER INC,Mono-c-Si,0,450.0,420.9,2.15,,,60.0,13.66,41.6,12.86,35.0,0.0056006,-0.11398400000000002,43.5,1.5856026499361375,13.670066900401471,5.420747725207341e-11,0.13053853322554188,177.13062754084598,10.83645297084611,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-450-120M-W,LENERGY POWER INC,Mono-c-Si,0,450.0,420.9,2.15,,,60.0,13.66,41.6,12.86,35.0,0.0056006,-0.11398400000000002,43.5,1.5856026499361375,13.670066900401471,5.420747725207341e-11,0.13053853322554188,177.13062754084598,10.83645297084611,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-455-120M-B,LENERGY POWER INC,Mono-c-Si,0,455.0,425.7,2.15,,,60.0,13.72,41.8,12.91,35.2,0.005625200000000001,-0.11453200000000001,43.5,1.5943760140040613,13.730276814146828,5.5448403704650506e-11,0.1276995531133126,170.4845360515125,11.002348522084858,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-455-120M-W,LENERGY POWER INC,Mono-c-Si,0,455.0,425.7,2.15,,,60.0,13.72,41.8,12.91,35.2,0.005625200000000001,-0.11453200000000001,43.5,1.5943760140040613,13.730276814146828,5.5448403704650506e-11,0.1276995531133126,170.4845360515125,11.002348522084858,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-460-120M-B,LENERGY POWER INC,Mono-c-Si,0,460.0,430.6,2.15,,,60.0,13.78,42.0,12.97,35.5,0.005649800000000001,-0.11508,43.5,1.6048760329727856,13.789356658736624,5.836397131312673e-11,0.11610083383142648,170.98726597041613,11.42308545647927,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-460-120M-W,LENERGY POWER INC,Mono-c-Si,0,460.0,430.6,2.15,,,60.0,13.78,42.0,12.97,35.5,0.005649800000000001,-0.11508,43.5,1.6048760329727856,13.789356658736624,5.836397131312673e-11,0.11610083383142648,170.98726597041613,11.42308545647927,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-505-144M-B,LENERGY POWER INC,Mono-c-Si,0,505.0,471.6,2.57,,,72.0,12.27,48.4,12.46,40.5,0.0050307,-0.132616,43.5,1.8778906819612968,12.270000887953415,7.859394731307207e-11,0.0009999942739727754,13818.213034405933,15.130769611191406,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +LENERGY POWER INC LP-505-144M-W,LENERGY POWER INC,Mono-c-Si,0,505.0,471.6,2.57,,,72.0,12.27,48.4,12.46,40.5,0.0050307,-0.132616,43.5,1.8778906819612968,12.270000887953415,7.859394731307207e-11,0.0009999942739727754,13818.213034405933,15.130769611191406,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +LENERGY POWER INC LP-510-144M-B,LENERGY POWER INC,Mono-c-Si,0,510.0,476.4,2.57,,,72.0,13.33,48.6,12.52,40.7,0.0054653,-0.13316400000000003,43.5,1.8501228107524041,13.342467024410535,5.109070725084125e-11,0.17338266957811577,185.3843333538123,10.534638086846627,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-510-144M-W,LENERGY POWER INC,Mono-c-Si,0,510.0,476.4,2.57,,,72.0,13.33,48.6,12.52,40.7,0.0054653,-0.13316400000000003,43.5,1.8501228107524041,13.342467024410535,5.109070725084125e-11,0.17338266957811577,185.3843333538123,10.534638086846627,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-515-144M-B,LENERGY POWER INC,Mono-c-Si,0,515.0,481.2,2.57,,,72.0,13.39,48.8,12.58,40.9,0.005489900000000001,-0.133712,43.5,1.7958120441294736,13.404028955488911,2.0717714486619574e-11,0.18140563102757953,173.1434255148437,2.725009435850728,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-515-144M-W,LENERGY POWER INC,Mono-c-Si,0,515.0,481.2,2.57,,,72.0,13.39,48.8,12.58,40.9,0.005489900000000001,-0.133712,43.5,1.7958120441294736,13.404028955488911,2.0717714486619574e-11,0.18140563102757953,173.1434255148437,2.725009435850728,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-520-144M-B,LENERGY POWER INC,Mono-c-Si,0,520.0,486.0,2.57,,,72.0,13.45,49.0,12.64,41.1,0.0055145,-0.13426000000000002,43.5,1.8663455897725316,13.46179700192599,5.2305638867259155e-11,0.16739114396924643,190.84602383162024,10.662438584790392,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-520-144M-W,LENERGY POWER INC,Mono-c-Si,0,520.0,486.0,2.57,,,72.0,13.45,49.0,12.64,41.1,0.0055145,-0.13426000000000002,43.5,1.8663455897725316,13.46179700192599,5.2305638867259155e-11,0.16739114396924643,190.84602383162024,10.662438584790392,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-525-144M-B,LENERGY POWER INC,Mono-c-Si,0,525.0,490.8,2.57,,,72.0,13.51,49.2,12.68,41.4,0.0055391,-0.134808,43.5,1.8783147578914288,13.522024318522416,5.5731832413721494e-11,0.15512841902122082,174.295529738621,11.19735456017256,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-525-144M-W,LENERGY POWER INC,Mono-c-Si,0,525.0,490.8,2.57,,,72.0,13.51,49.2,12.68,41.4,0.0055391,-0.134808,43.5,1.8783147578914288,13.522024318522416,5.5731832413721494e-11,0.15512841902122082,174.295529738621,11.19735456017256,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-530-144M-B,LENERGY POWER INC,Mono-c-Si,0,530.0,495.6,2.57,,,72.0,13.57,49.4,12.74,41.6,0.005563700000000001,-0.135356,43.5,1.8864227652601842,13.581691558925481,5.636307901052206e-11,0.15224458705703606,176.7051840238796,11.257651727246772,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-530-144M-W,LENERGY POWER INC,Mono-c-Si,0,530.0,495.6,2.57,,,72.0,13.57,49.4,12.74,41.6,0.005563700000000001,-0.135356,43.5,1.8864227652601842,13.581691558925481,5.636307901052206e-11,0.15224458705703606,176.7051840238796,11.257651727246772,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-535-144M-B,LENERGY POWER INC,Mono-c-Si,0,535.0,500.4,2.57,,,72.0,13.63,49.6,12.8,41.8,0.0055883,-0.13590400000000002,43.5,1.8945302364142642,13.641365100356614,5.6996604992526095e-11,0.1493882271443208,179.15913602325233,11.317394946899189,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-535-144M-W,LENERGY POWER INC,Mono-c-Si,0,535.0,500.4,2.57,,,72.0,13.63,49.6,12.8,41.8,0.0055883,-0.13590400000000002,43.5,1.8945302364142642,13.641365100356614,5.6996604992526095e-11,0.1493882271443208,179.15913602325233,11.317394946899189,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-540-144M-B,LENERGY POWER INC,Mono-c-Si,0,540.0,505.2,2.57,,,72.0,13.7,49.8,12.86,42.0,0.005617,-0.13645200000000002,43.5,1.9033440127135945,13.711529013396602,5.8187692663182124e-11,0.1463361368437131,173.89216481694532,11.45946391909454,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-540-144M-W,LENERGY POWER INC,Mono-c-Si,0,540.0,505.2,2.57,,,72.0,13.7,49.8,12.86,42.0,0.005617,-0.13645200000000002,43.5,1.9033440127135945,13.711529013396602,5.8187692663182124e-11,0.1463361368437131,173.89216481694532,11.45946391909454,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-545-144M-B,LENERGY POWER INC,Mono-c-Si,0,545.0,510.0,2.57,,,72.0,13.76,50.0,12.92,42.2,0.0056416,-0.137,43.5,1.911450632751649,13.77120516382531,5.882950505454602e-11,0.14353447157014093,176.26108660730966,11.517820017613568,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-545-144M-W,LENERGY POWER INC,Mono-c-Si,0,545.0,510.0,2.57,,,72.0,13.76,50.0,12.92,42.2,0.0056416,-0.137,43.5,1.911450632751649,13.77120516382531,5.882950505454602e-11,0.14353447157014093,176.26108660730966,11.517820017613568,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LENERGY POWER INC LP-550-144M-B,LENERGY POWER INC,Mono-c-Si,0,550.0,514.8,2.57,,,72.0,13.82,50.2,12.98,42.4,0.005666200000000001,-0.137548,43.5,1.919556734441395,13.830887444046168,5.947352953027289e-11,0.1407591199376799,178.672886669936,11.575646929699259,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +LENERGY POWER INC LP-550-144M-W,LENERGY POWER INC,Mono-c-Si,0,550.0,514.8,2.57,,,72.0,13.82,50.2,12.98,42.4,0.005666200000000001,-0.137548,43.5,1.919556734441395,13.830887444046168,5.947352953027289e-11,0.1407591199376799,178.672886669936,11.575646929699259,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG210P1C-G2,LG Electronics Inc,Multi-c-Si,0,210.0,188.3,1.60974,1.626,0.99,60.0,7.99,35.7,7.32,28.7,-7.99e-05,-0.11138400000000001,45.7,1.439560946275398,8.019035165271733,1.3019710976306877e-10,0.3711945369441443,102.14663541598937,9.570660302725562,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG210P1W-G1,LG Electronics Inc,Multi-c-Si,0,210.0,188.9,1.637457,1.649,0.993,60.0,7.99,35.7,7.32,28.7,0.0011985,-0.11531100000000001,44.7,1.473759006266306,8.017391375983788,2.31761927286903e-10,0.36143311771920983,105.42919644618203,10.624635352936277,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG215P1C-G2,LG Electronics Inc,Multi-c-Si,0,215.0,192.9,1.60974,1.626,0.99,60.0,8.1,35.8,7.46,28.9,-8.1e-05,-0.11169599999999999,45.7,1.442887460386336,8.12391297923019,1.3116075062516733e-10,0.3484603146080999,118.03333307579084,9.495032199810003,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG215P1W,LG Electronics Inc,Multi-c-Si,0,215.0,191.0,1.646394,1.658,0.993,60.0,7.99,36.0,7.39,29.1,0.0030361999999999997,-0.12204000000000001,45.4,1.5748397981047717,8.005180116545036,9.197050584897306e-10,0.31398008332639266,165.26233207125298,17.42053837868812,-0.505,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG215P1W-G1,LG Electronics Inc,Multi-c-Si,0,215.0,193.5,1.637457,1.649,0.993,60.0,8.1,35.8,7.46,28.9,0.001215,-0.115634,44.7,1.47717681632064,8.1224104773306,2.335918839692207e-10,0.3388363237448781,122.46835873282419,10.553923412645018,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG220M1C-G2,LG Electronics Inc,Mono-c-Si,0,220.0,196.6,1.60974,1.626,0.99,60.0,8.2,36.2,7.51,29.3,-0.0014759999999999997,-0.12199400000000002,43.8,1.5524199919483928,8.223899389856173,5.885042731726138e-10,0.3115606920287133,106.89804021693234,14.386846957804323,-0.525,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG220P1C-G2,LG Electronics Inc,Multi-c-Si,0,220.0,197.5,1.60974,1.626,0.99,60.0,8.21,36.1,7.62,28.9,-8.21e-05,-0.11263200000000001,45.7,1.4422887961293178,8.229331507181593,1.0796650478879818e-10,0.3843288702533573,163.22266726442805,7.654280224470352,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG220P1W,LG Electronics Inc,Multi-c-Si,0,220.0,195.5,1.646394,1.658,0.993,60.0,8.0,36.6,7.39,29.2,0.00304,-0.12407400000000003,45.4,1.5896661593722299,8.018335180785167,7.814833071486404e-10,0.3808083634171353,166.15421989559113,15.869896168409872,-0.505,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG220P1W-G1,LG Electronics Inc,Multi-c-Si,0,220.0,198.1,1.637457,1.649,0.993,60.0,8.21,36.1,7.62,28.9,0.0012315,-0.11660300000000001,44.7,1.4762925538908,8.227888832758264,1.9240129301563608e-10,0.37506297955605306,172.13349673283773,8.696466878079598,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG220R1C-G2,LG Electronics Inc,Multi-c-Si,0,220.0,193.2,1.5934799999999998,1.626,0.98,60.0,8.06,36.0,7.69,28.7,0.00398164,-0.143208,46.2,1.629732032013758,8.060002394877975,2.0557776419391996e-09,0.2962816968823182,999998.2464445739,6.457654070685335,-0.5367,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG220R1W-G2,LG Electronics Inc,Multi-c-Si,0,220.0,193.2,1.5934799999999998,1.626,0.98,60.0,8.06,36.0,7.69,28.7,0.00398164,-0.143208,46.2,1.629732032013758,8.060002394877975,2.0557776419391996e-09,0.2962816968823182,999998.2464445739,6.457654070685335,-0.5367,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG225M1C-G2,LG Electronics Inc,Mono-c-Si,0,225.0,201.2,1.60974,1.626,0.99,60.0,8.29,36.5,7.65,29.5,-0.0014921999999999997,-0.123005,43.8,1.5571605328076903,8.309011719162068,5.317099293510863e-10,0.3182891176805779,138.7889801559304,13.329540194498462,-0.525,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG225P1C-G2,LG Electronics Inc,Multi-c-Si,0,225.0,202.1,1.60974,1.626,0.99,60.0,8.3,36.3,7.76,29.0,-8.300000000000001e-05,-0.113256,45.7,1.443225939330736,8.312902618606755,9.74500316981101e-11,0.39122826101432767,251.6694381179378,6.651955488044535,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG225P1W,LG Electronics Inc,Multi-c-Si,0,225.0,200.1,1.646394,1.658,0.993,60.0,8.24,36.13,7.39,29.0,0.0031311999999999998,-0.12248070000000001,45.4,1.602117406468379,8.28101127040207,1.244400411396567e-09,0.33425813982021035,67.15928153076378,20.147155806455434,-0.505,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG225P1W-G1,LG Electronics Inc,Multi-c-Si,0,225.0,202.8,1.637457,1.649,0.993,60.0,8.3,36.3,7.76,29.0,0.001245,-0.117249,44.7,1.4771021855852564,8.311580323986838,1.7372162915388033e-10,0.3821930289814249,273.9303753560682,7.686413581421316,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG225R1C-G2,LG Electronics Inc,Multi-c-Si,0,225.0,197.7,1.5934799999999998,1.626,0.98,60.0,8.21,36.4,7.8,28.9,0.00405574,-0.1447992,46.2,1.6409889772397228,8.210002725793434,1.9095527924068442e-09,0.33101641248400715,999991.266349245,5.659956541948608,-0.5367,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG225R1W-G2,LG Electronics Inc,Multi-c-Si,0,225.0,197.7,1.5934799999999998,1.626,0.98,60.0,8.21,36.4,7.8,28.9,0.00405574,-0.1447992,46.2,1.6409889772397228,8.210002725793434,1.9095527924068442e-09,0.33101641248400715,999991.266349245,5.659956541948608,-0.5367,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG230M1C-G2,LG Electronics Inc,Mono-c-Si,0,230.0,205.8,1.60974,1.626,0.99,60.0,8.37,36.6,7.81,29.5,-0.0015065999999999999,-0.12334200000000002,43.8,1.5493362303355545,8.380985250072774,4.532364212024695e-10,0.32939753391485777,250.9781662662357,11.75652959384006,-0.525,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG230N8K-G4,LG Electronics Inc,Mono-c-Si,0,230.0,212.9,1.274,1.3,0.98,48.0,9.9,30.0,9.71,23.7,0.00297,-0.084,44.6,1.121900453501675,9.900002596248754,2.4124120813542876e-11,0.2238885667348471,853543.5103102243,4.343970418780799,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG230P1C-G2,LG Electronics Inc,Multi-c-Si,0,230.0,206.7,1.60974,1.626,0.99,60.0,8.39,36.4,7.91,29.1,-8.39e-05,-0.113568,45.7,1.441714825677775,8.394974636450218,9.039952384382878e-11,0.3847781429958112,648.9497541029474,5.887142767664064,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG230P1W,LG Electronics Inc,Multi-c-Si,0,230.0,204.7,1.646394,1.658,0.993,60.0,8.26,36.4,7.39,29.5,0.0031387999999999997,-0.123396,45.4,1.6263099070128166,8.297291005308939,1.4716339556652153e-09,0.2895094258849249,64.12667489756824,21.78591359090722,-0.505,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG230P1W-G1,LG Electronics Inc,Multi-c-Si,0,230.0,207.4,1.637457,1.649,0.993,60.0,8.39,36.4,7.91,29.1,0.0012585,-0.117572,44.7,1.4754457147585196,8.393826367311261,1.6121390838339603e-10,0.37596305715874456,824.3669198775104,6.917584836821022,-0.467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG230R1C-G2,LG Electronics Inc,Multi-c-Si,0,230.0,202.2,1.5934799999999998,1.626,0.98,60.0,8.35,36.6,7.93,29.1,0.0041249,-0.14559480000000002,46.2,1.6508643332938815,8.35000270812921,1.9646590894945525e-09,0.32335450968748836,999999.9348714054,5.759415545229927,-0.5367,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG230R1W-G2,LG Electronics Inc,Multi-c-Si,0,230.0,202.2,1.5934799999999998,1.626,0.98,60.0,8.35,36.6,7.93,29.1,0.0041249,-0.14559480000000002,46.2,1.6508643332938815,8.35000270812921,1.9646590894945525e-09,0.32335450968748836,999999.9348714054,5.759415545229927,-0.5367,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG235M1C-G2,LG Electronics Inc,Mono-c-Si,0,235.0,210.4,1.60974,1.626,0.99,60.0,8.49,36.8,7.94,29.6,-0.0015282,-0.124016,43.8,1.5540251454752898,8.499401293836453,4.353695368162268e-10,0.33578755934929155,303.23880129177064,11.26053259309787,-0.525,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG235N8K-G4,LG Electronics Inc,Mono-c-Si,0,235.0,217.6,1.274,1.3,0.98,48.0,9.96,30.2,9.76,24.1,0.002988,-0.08456000000000001,44.6,1.133714944934837,9.960002093272347,2.6883306632379485e-11,0.18083618140917745,860212.4453924905,5.207828326995019,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG235P1W,LG Electronics Inc,Multi-c-Si,0,235.0,209.2,1.646394,1.658,0.993,60.0,8.3,36.3,7.39,29.8,0.003154,-0.123057,45.4,1.640038897463564,8.331927891558498,1.881559927575612e-09,0.22435093908842746,58.32245523732391,24.222977422353743,-0.505,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG235R1C-G2,LG Electronics Inc,Multi-c-Si,0,235.0,206.8,1.5934799999999998,1.626,0.98,60.0,8.48,36.9,7.97,29.5,0.00418912,-0.14678819999999998,46.2,1.6636576398161953,8.481620359571968,1.9711954877778024e-09,0.3352235379041992,1754.370020356503,5.661317789749677,-0.5367,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG235R1W-G2,LG Electronics Inc,Multi-c-Si,0,235.0,206.8,1.5934799999999998,1.626,0.98,60.0,8.48,36.9,7.97,29.5,0.00418912,-0.14678819999999998,46.2,1.6636576398161953,8.481620359571968,1.9711954877778024e-09,0.3352235379041992,1754.370020356503,5.661317789749677,-0.5367,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG240M1C-G2,LG Electronics Inc,Mono-c-Si,0,240.0,215.0,1.60974,1.626,0.99,60.0,8.58,36.9,8.1,29.7,-0.0015443999999999998,-0.124353,43.8,1.5510501837368502,8.581525697264683,3.98610765430925e-10,0.33071817667925335,1859.848542465324,10.344678475784221,-0.525,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG240N8K-G4,LG Electronics Inc,Mono-c-Si,0,240.0,222.4,1.274,1.3,0.98,48.0,10.01,30.5,9.8,24.5,0.0030029999999999996,-0.0854,44.6,1.1477413328910264,10.010001849580144,2.8808500010630623e-11,0.1596643403077014,863864.6790724925,5.7532645878430975,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG240R1C-G2,LG Electronics Inc,Multi-c-Si,0,240.0,211.3,1.5934799999999998,1.626,0.98,60.0,8.61,37.2,8.02,30.0,0.0042533399999999996,-0.14798160000000002,46.2,1.6948086426316242,8.61882838102835,2.4908493694229884e-09,0.2931735307018907,285.92179439877157,7.598466217353842,-0.5367,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG240R1W-G2,LG Electronics Inc,Multi-c-Si,0,240.0,211.3,1.5934799999999998,1.626,0.98,60.0,8.61,37.2,8.02,30.0,0.0042533399999999996,-0.14798160000000002,46.2,1.6948086426316242,8.61882838102835,2.4908493694229884e-09,0.2931735307018907,285.92179439877157,7.598466217353842,-0.5367,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG240S1C-G2,LG Electronics Inc,Mono-c-Si,0,240.0,215.9,1.5934799999999998,1.626,0.98,60.0,8.58,36.9,8.1,29.7,0.0035750000000000005,-0.12473377659574467,45.2,1.5465035927253563,8.58165318330374,3.716207130289893e-10,0.3318647043647298,1722.3755877668777,8.70968876848375,-0.4724300905868452,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG240S1K-G3,LG Electronics Inc,Mono-c-Si,0,240.0,213.2,1.624196,1.634,0.994,60.0,8.42,37.96,7.91,30.37,0.00417632,-0.12325612,48.8,1.5537300070429918,8.426819196101318,2.0466481779938755e-10,0.3843338408814517,474.55617584682875,7.979310870146053,-0.4447,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG245M1C-G2,LG Electronics Inc,Mono-c-Si,0,245.0,213.4,1.5934799999999998,1.626,0.98,60.0,8.67,37.0,8.23,29.8,0.0036240599999999997,-0.159877,45.5,1.7729029155060156,8.7591514974179,7.565765750750556e-09,0.2702438833542174,999999.978266632,8.36554564717641,-0.6023,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG245M1W-G2,LG Electronics Inc,Mono-c-Si,0,245.0,213.4,1.5934799999999998,1.626,0.98,60.0,8.67,37.0,8.23,29.8,0.0036240599999999997,-0.159877,45.5,1.7729029155060156,8.7591514974179,7.565765750750556e-09,0.2702438833542174,999999.978266632,8.36554564717641,-0.6023,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG245N8K-G4,LG Electronics Inc,Mono-c-Si,0,245.0,227.1,1.274,1.3,0.98,48.0,10.06,30.8,9.84,24.9,0.0030180000000000003,-0.08624000000000001,44.6,1.1618219860347192,10.060001721866723,3.0861195156248985e-11,0.14822779350421708,865765.3092543482,6.298689213122103,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG245S1C-G2,LG Electronics Inc,Mono-c-Si,0,245.0,220.6,1.5934799999999998,1.626,0.98,60.0,8.67,37.0,8.23,29.8,0.0036125000000000003,-0.1250718085106383,45.2,1.5494696749860513,8.700219819871956,3.706385324360747e-10,0.3254795760238121,999999.9226681871,8.558950811060221,-0.4724300905868452,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG245S1C-G3,LG Electronics Inc,Mono-c-Si,0,245.0,221.5,1.624196,1.634,0.994,60.0,8.52,38.11,8.02,30.57,0.004547712418300653,-0.13036039682539682,44.9,1.5918529807599742,8.524130694235415,3.3942598170054087e-10,0.36155501160634174,745.7462881021196,6.573815048630263,-0.4589,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG245S1K-G3,LG Electronics Inc,Mono-c-Si,0,245.0,217.8,1.624196,1.634,0.994,60.0,8.52,38.11,8.02,30.57,0.004225919999999999,-0.12374317,48.8,1.560583849317279,8.52509325977434,2.098577220213956e-10,0.36954742472899316,618.1787389520008,8.088240847003336,-0.4447,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG250N8K-G4,LG Electronics Inc,Mono-c-Si,0,250.0,231.9,1.274,1.3,0.98,48.0,10.1,31.1,9.89,25.3,0.0030299999999999997,-0.08708,44.6,1.1768806655651964,10.1000014582348,3.370897982270062e-11,0.12553760101823117,869221.1108493794,7.022865998874312,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG250S1C-G2,LG Electronics Inc,Mono-c-Si,0,250.0,225.2,1.5934799999999998,1.626,0.98,60.0,8.76,37.1,8.37,29.9,0.0036500000000000005,-0.1254098404255319,45.2,1.5616811491531513,8.760002450891575,4.218978202113319e-10,0.27959863174055594,999998.0290523706,9.636014524213895,-0.4724300905868452,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG250S1C-G3,LG Electronics Inc,Mono-c-Si,0,250.0,226.1,1.624196,1.634,0.994,60.0,8.62,38.26,8.13,30.77,0.0046010893246187365,-0.13087349206349205,44.9,1.598879034316006,8.622567236494382,3.4804294474659297e-10,0.3472223213045767,1165.866877892584,6.683141527735965,-0.4589,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG250S1K-A3,LG Electronics Inc,Mono-c-Si,0,250.0,225.7,1.5876000000000001,1.62,0.98,60.0,8.68,37.6,8.13,30.8,0.00434,-0.11656,46.8,1.5358169413391376,8.689185708072024,1.9914694812885685e-10,0.2720976581462992,257.11767033221327,12.629817808608921,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG250S1K-B3,LG Electronics Inc,Mono-c-Si,0,250.0,227.4,1.5876000000000001,1.62,0.98,60.0,8.68,37.6,8.13,30.8,0.0034720000000000003,-0.11656,44.8,1.5384692208959672,8.689109099942709,2.0775099776347605e-10,0.27141024736200137,258.62501837967375,13.132930827307089,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG250S1K-G3,LG Electronics Inc,Mono-c-Si,0,250.0,222.4,1.624196,1.634,0.994,60.0,8.62,38.26,8.13,30.77,0.00427552,-0.12423021999999999,48.8,1.5674544266785944,8.6234762530869,2.1517587208470125e-10,0.35515880880187534,880.6810096867927,8.198319608403823,-0.4447,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1C-A3,LG Electronics Inc,Mono-c-Si,0,255.0,231.1,1.5876000000000001,1.62,0.98,60.0,8.98,38.0,8.27,30.9,0.003592,-0.1178,46.1,1.5461717526097074,9.004018975836402,1.8372959875013133e-10,0.29966539247437707,112.03622246943877,11.781551946801612,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1C-B3,LG Electronics Inc,Mono-c-Si,0,255.0,233.8,1.5876000000000001,1.62,0.98,60.0,8.98,38.0,8.27,30.9,0.002694,-0.1178,43.7,1.5320643889045205,9.004638206368908,1.464522784880026e-10,0.30327284252489545,110.53524610065506,9.887727890384419,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1C-G2,LG Electronics Inc,Mono-c-Si,0,255.0,229.8,1.5934799999999998,1.626,0.98,60.0,8.85,37.2,8.5,30.0,0.0036875000000000002,-0.12574787234042553,45.2,1.570671246457209,8.85020177654999,4.5802996601053405e-10,0.24877340391789182,10911.376408310132,10.275068450761303,-0.4724300905868452,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG255S1C-G3,LG Electronics Inc,Mono-c-Si,0,255.0,230.8,1.624196,1.634,0.994,60.0,8.72,38.41,8.24,30.97,0.00465446623093682,-0.1313865873015873,44.9,1.6059215940804699,8.721109403698312,3.5686382810360846e-10,0.3332701048520214,2619.533415411751,6.793476012944992,-0.4589,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1K-A3,LG Electronics Inc,Mono-c-Si,0,255.0,230.3,1.5876000000000001,1.62,0.98,60.0,8.78,37.9,8.26,30.9,0.00439,-0.11749,46.8,1.5404770892300417,8.78644090466047,1.795722064984891e-10,0.2922687940028743,398.40992132513225,11.572041547831773,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1K-B3,LG Electronics Inc,Mono-c-Si,0,255.0,232.0,1.5876000000000001,1.62,0.98,60.0,8.78,37.9,8.26,30.9,0.0035119999999999995,-0.11749,44.8,1.5431208092836688,8.786367046890447,1.8732023821649514e-10,0.2915974445087652,402.10570572258575,12.071201912661715,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1K-G3,LG Electronics Inc,Mono-c-Si,0,255.0,227.0,1.624196,1.634,0.994,60.0,8.72,38.41,8.24,30.97,0.004325120000000001,-0.12471726999999999,48.8,1.574340942163753,8.72196496868198,2.206200240370156e-10,0.3411522652739787,1513.9425135694366,8.309438593193132,-0.4447,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1W-A3,LG Electronics Inc,Mono-c-Si,0,255.0,231.1,1.5876000000000001,1.62,0.98,60.0,8.98,38.0,8.27,30.9,0.003592,-0.1178,46.1,1.5461717526097074,9.004018975836402,1.8372959875013133e-10,0.29966539247437707,112.03622246943877,11.781551946801612,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG255S1W-B3,LG Electronics Inc,Mono-c-Si,0,255.0,233.8,1.5876000000000001,1.62,0.98,60.0,8.98,38.0,8.27,30.9,0.002694,-0.1178,43.7,1.5320643889045205,9.004638206368908,1.464522784880026e-10,0.30327284252489545,110.53524610065506,9.887727890384419,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260N9K-G4,LG Electronics Inc,Mono-c-Si,0,260.0,241.7,1.4307999999999998,1.46,0.98,54.0,9.55,35.2,8.88,29.3,0.0028650000000000004,-0.09856000000000002,43.6,1.3474134002139424,9.565862068538362,4.1821119332878446e-11,0.19592167090577428,117.95762749782801,9.503728627744566,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1C-A3,LG Electronics Inc,Mono-c-Si,0,260.0,235.8,1.5876000000000001,1.62,0.98,60.0,9.05,38.1,8.38,31.1,0.0036200000000000004,-0.11811,46.1,1.5490674999042247,9.068968491499701,1.8285756208194292e-10,0.28193722884502287,134.51422977664078,11.649327542027917,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1C-B3,LG Electronics Inc,Mono-c-Si,0,260.0,238.5,1.5876000000000001,1.62,0.98,60.0,9.05,38.1,8.38,31.1,0.0027150000000000004,-0.11811,43.7,1.534927922254105,9.069522906885695,1.4571800119403237e-10,0.2855115704611599,132.3511817340346,9.754811229376417,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1C-G2,LG Electronics Inc,Mono-c-Si,0,260.0,234.5,1.5934799999999998,1.626,0.98,60.0,8.94,37.3,8.64,30.1,0.003725,-0.12608590425531915,45.2,1.5795015344356274,8.9400019032071,4.959661247738346e-10,0.21275658557632682,999997.0783614939,10.89329738655579,-0.4724300905868452,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG260S1C-G3,LG Electronics Inc,Mono-c-Si,0,260.0,235.0,1.5876000000000001,1.62,0.98,60.0,8.82,38.56,8.35,31.17,0.00441,-0.12339200000000002,46.3,1.5732020819908359,8.820765954458668,1.9962841805683027e-10,0.3295062175836674,3794.283910521129,8.918492990311776,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1K-A3,LG Electronics Inc,Mono-c-Si,0,260.0,234.9,1.5876000000000001,1.62,0.98,60.0,8.88,38.2,8.34,31.2,0.00444,-0.11842000000000001,46.8,1.5555642396356588,8.887688034069768,1.8970355717461341e-10,0.2833502754861915,327.28141867597236,11.971853504463963,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1K-B3,LG Electronics Inc,Mono-c-Si,0,260.0,236.7,1.5876000000000001,1.62,0.98,60.0,8.88,38.2,8.34,31.2,0.003552,-0.11842000000000001,44.8,1.5582395876461648,8.887611961095107,1.9789097333957337e-10,0.28267624683586756,329.76591599467207,12.472428253258919,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1K-G3,LG Electronics Inc,Mono-c-Si,0,260.0,231.6,1.624196,1.634,0.994,60.0,8.82,38.56,8.35,31.17,0.0043747199999999995,-0.12520432,48.8,1.581242619486813,8.820556346367958,2.261908655162975e-10,0.3275128868625728,5192.214692427934,8.421493028337826,-0.4447,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1W-A3,LG Electronics Inc,Mono-c-Si,0,260.0,235.8,1.5876000000000001,1.62,0.98,60.0,9.05,38.1,8.38,31.1,0.0036200000000000004,-0.11811,46.1,1.5490674999042247,9.068968491499701,1.8285756208194292e-10,0.28193722884502287,134.51422977664078,11.649327542027917,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1W-B3,LG Electronics Inc,Mono-c-Si,0,260.0,238.5,1.5876000000000001,1.62,0.98,60.0,9.05,38.1,8.38,31.1,0.0027150000000000004,-0.11811,43.7,1.534927922254105,9.069522906885695,1.4571800119403237e-10,0.2855115704611599,132.3511817340346,9.754811229376417,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG260S1W-G2,LG Electronics Inc,Mono-c-Si,0,260.0,230.4,1.5934799999999998,1.626,0.98,60.0,8.94,37.3,8.64,30.1,0.0032452199999999996,-0.1434185,46.1,1.6666152155222949,8.940001598798938,1.7042182915915825e-09,0.17853014054069008,999999.968004037,7.722213482943678,-0.524,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG260S1W-G3,LG Electronics Inc,Mono-c-Si,0,260.0,235.0,1.5876000000000001,1.62,0.98,60.0,8.82,38.56,8.35,31.17,0.00441,-0.12339200000000002,46.3,1.5732020819908359,8.820765954458668,1.9962841805683027e-10,0.3295062175836674,3794.283910521129,8.918492990311776,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265N9K-G4,LG Electronics Inc,Mono-c-Si,0,265.0,246.4,1.4307999999999998,1.46,0.98,54.0,9.6,35.5,8.93,29.7,0.0028799999999999997,-0.0994,43.6,1.3622910828287869,9.614303180779569,4.486606633938817e-11,0.17713729434487943,118.89090022491945,10.078786896384944,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1C-A3,LG Electronics Inc,Mono-c-Si,0,265.0,240.4,1.5876000000000001,1.62,0.98,60.0,9.11,38.3,8.49,31.3,0.003644,-0.11873,46.1,1.5529058985640236,9.124043546739998,1.732720271606165e-10,0.2770667055184114,179.7322187225532,11.082563492315115,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1C-B3,LG Electronics Inc,Mono-c-Si,0,265.0,243.2,1.5876000000000001,1.62,0.98,60.0,9.11,38.3,8.49,31.3,0.0027329999999999998,-0.11873,43.7,1.5387417227381581,9.124535303567393,1.380152452510436e-10,0.2805989874392687,175.8653933314036,9.19372841827417,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1C-G3,LG Electronics Inc,Mono-c-Si,0,265.0,239.6,1.5876000000000001,1.62,0.98,60.0,8.92,38.71,8.46,31.37,0.00446,-0.123872,46.3,1.5805730468338262,8.925995065717672,2.0620425852274357e-10,0.31597795750546076,999999.9270803973,9.095160582512724,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG265S1K-A3,LG Electronics Inc,Mono-c-Si,0,265.0,239.6,1.5876000000000001,1.62,0.98,60.0,9.03,38.4,8.42,31.5,0.004515,-0.11904,46.8,1.5734643172478755,9.042476613479332,2.2260890026691687e-10,0.26040536982017864,188.46946235827542,13.302501326406142,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1K-B3,LG Electronics Inc,Mono-c-Si,0,265.0,241.4,1.5876000000000001,1.62,0.98,60.0,9.03,38.4,8.42,31.5,0.0036119999999999998,-0.11904,44.8,1.5761990805385477,9.042389846420345,2.3225817881782262e-10,0.25971958298729575,189.2895120393153,13.809254509334965,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1W-A3,LG Electronics Inc,Mono-c-Si,0,265.0,240.4,1.5876000000000001,1.62,0.98,60.0,9.11,38.3,8.49,31.3,0.003644,-0.11873,46.1,1.5529058985640236,9.124043546739998,1.732720271606165e-10,0.2770667055184114,179.7322187225532,11.082563492315115,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1W-B3,LG Electronics Inc,Mono-c-Si,0,265.0,243.2,1.5876000000000001,1.62,0.98,60.0,9.11,38.3,8.49,31.3,0.0027329999999999998,-0.11873,43.7,1.5387417227381581,9.124535303567393,1.380152452510436e-10,0.2805989874392687,175.8653933314036,9.19372841827417,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG265S1W-G3,LG Electronics Inc,Mono-c-Si,0,265.0,239.6,1.5876000000000001,1.62,0.98,60.0,8.92,38.71,8.46,31.37,0.00446,-0.123872,46.3,1.5805730468338262,8.925995065717672,2.0620425852274357e-10,0.31597795750546076,999999.9270803973,9.095160582512724,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG270N1C-G3,LG Electronics Inc,Mono-c-Si,0,270.0,244.4,1.624196,1.634,0.994,60.0,9.31,38.57,8.74,31.21,0.002793,-0.11956699999999999,46.5,1.5352973551576539,9.319851077623424,1.1297442811948403e-10,0.3186640973090201,301.1612597793643,7.232030113508816,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270N1W-G3,LG Electronics Inc,Mono-c-Si,0,270.0,244.4,1.624196,1.634,0.994,60.0,9.31,38.57,8.74,31.21,0.002793,-0.11956699999999999,46.5,1.5352973551576539,9.319851077623424,1.1297442811948403e-10,0.3186640973090201,301.1612597793643,7.232030113508816,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270N9K-G4,LG Electronics Inc,Mono-c-Si,0,270.0,251.2,1.4307999999999998,1.46,0.98,54.0,9.65,35.8,8.98,30.1,0.002895,-0.10024000000000001,43.6,1.3771567230831088,9.662766562067366,4.8053526305254867e-11,0.15857834021909767,119.86633416081652,10.642265633177033,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1C-A3,LG Electronics Inc,Mono-c-Si,0,270.0,245.1,1.5876000000000001,1.62,0.98,60.0,9.17,38.5,8.58,31.5,0.0036680000000000003,-0.11935,46.1,1.5587609920233354,9.18101109585743,1.6908007807845922e-10,0.2720571917534868,226.56823186801773,10.789867531313527,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1C-B3,LG Electronics Inc,Mono-c-Si,0,270.0,247.9,1.5876000000000001,1.62,0.98,60.0,9.17,38.5,8.58,31.5,0.002751,-0.11935,43.7,1.5445484872271844,9.181463315951751,1.34642568817922e-10,0.27556437502497977,220.4358191177376,8.903782916944204,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1C-G3,LG Electronics Inc,Mono-c-Si,0,270.0,244.3,1.5876000000000001,1.62,0.98,60.0,9.02,38.86,8.57,31.57,0.00451,-0.124352,46.3,1.5885971707661315,9.039854092361491,2.1504042422789764e-10,0.3025026185779925,999999.9734090243,9.353803130439555,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG270S1C-G4,LG Electronics Inc,Mono-c-Si,0,270.0,247.3,1.5876000000000001,1.62,0.98,60.0,9.17,38.5,8.58,31.5,0.002751,-0.11935,44.2,1.5445484872271844,9.181463315951751,1.34642568817922e-10,0.27556437502497977,220.4358191177376,8.903782916944204,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1C-L4,LG Electronics Inc,Mono-c-Si,0,270.0,246.8,1.5876000000000001,1.62,0.98,60.0,9.17,38.2,8.7,31.1,0.002751,-0.11842000000000001,45.6,1.4848545565756792,9.171521895792253,6.146180196490607e-11,0.30312206856206164,1826.4259319392338,2.2064616648913153,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1K-B3,LG Electronics Inc,Mono-c-Si,0,270.0,241.6,1.5876000000000001,1.62,0.98,60.0,9.12,38.6,8.52,31.7,0.0036479999999999998,-0.11966,49.1,1.5673525430433484,9.131561238985809,1.8023149030047796e-10,0.25786513938584266,203.4150605162897,11.417392260730772,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1W-A3,LG Electronics Inc,Mono-c-Si,0,270.0,245.1,1.5876000000000001,1.62,0.98,60.0,9.17,38.5,8.58,31.5,0.0036680000000000003,-0.11935,46.1,1.5587609920233354,9.18101109585743,1.6908007807845922e-10,0.2720571917534868,226.56823186801773,10.789867531313527,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1W-B3,LG Electronics Inc,Mono-c-Si,0,270.0,247.9,1.5876000000000001,1.62,0.98,60.0,9.17,38.5,8.58,31.5,0.002751,-0.11935,43.7,1.5445484872271844,9.181463315951751,1.34642568817922e-10,0.27556437502497977,220.4358191177376,8.903782916944204,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1W-G3,LG Electronics Inc,Mono-c-Si,0,270.0,244.3,1.5876000000000001,1.62,0.98,60.0,9.02,38.86,8.57,31.57,0.00451,-0.124352,46.3,1.5885971707661315,9.039854092361491,2.1504042422789764e-10,0.3025026185779925,999999.9734090243,9.353803130439555,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG270S1W-G4,LG Electronics Inc,Mono-c-Si,0,270.0,247.3,1.5876000000000001,1.62,0.98,60.0,9.17,38.5,8.58,31.5,0.002751,-0.11935,44.2,1.5445484872271844,9.181463315951751,1.34642568817922e-10,0.27556437502497977,220.4358191177376,8.903782916944204,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG270S1W-L4,LG Electronics Inc,Mono-c-Si,0,270.0,246.8,1.5876000000000001,1.62,0.98,60.0,9.17,38.2,8.7,31.1,0.002751,-0.11842000000000001,45.6,1.4848545565756792,9.171521895792253,6.146180196490607e-11,0.30312206856206164,1826.4259319392338,2.2064616648913153,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275N1C-G3,LG Electronics Inc,Mono-c-Si,0,275.0,249.1,1.624196,1.634,0.994,60.0,9.44,38.72,8.85,31.36,0.002832,-0.120032,46.5,1.5431122927400536,9.45117264922893,1.1784072802711727e-10,0.31167878789750453,263.3438028497171,7.48187570235257,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275N1K-A3,LG Electronics Inc,Mono-c-Si,0,275.0,248.0,1.5876000000000001,1.62,0.98,72.0,9.35,39.2,8.8,31.3,0.0037400000000000003,-0.11368,49.3,1.5082333257727831,9.359078982175596,4.775799996035488e-11,0.387616982507109,399.1878201006996,6.823210933879461,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275N1K-B3,LG Electronics Inc,Mono-c-Si,0,275.0,245.5,1.5876000000000001,1.62,0.98,60.0,9.35,39.18,8.8,31.33,0.0037400000000000003,-0.11362199999999999,50.9,1.5248314039269002,9.358455435432834,6.423682037147723e-11,0.37746337479892733,417.39811362732354,9.401743315767007,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275N1W-G3,LG Electronics Inc,Mono-c-Si,0,275.0,249.1,1.624196,1.634,0.994,60.0,9.44,38.72,8.85,31.36,0.002832,-0.120032,46.5,1.5431122927400536,9.45117264922893,1.1784072802711727e-10,0.31167878789750453,263.3438028497171,7.48187570235257,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275N9K-G4,LG Electronics Inc,Mono-c-Si,0,275.0,256.0,1.4307999999999998,1.46,0.98,54.0,9.7,36.1,9.02,30.5,0.0029099999999999994,-0.10108000000000002,43.6,1.3928243402502678,9.711718488226047,5.210186938651076e-11,0.14003167304798925,115.91147359106449,11.323297492001865,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1C-B3,LG Electronics Inc,Mono-c-Si,0,275.0,252.6,1.5876000000000001,1.62,0.98,60.0,9.26,38.7,8.68,31.7,0.002778,-0.11997000000000001,43.7,1.552084434303083,9.270082538841384,1.351785049877559e-10,0.269558519544054,247.56780602288046,8.846070025063558,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1C-G4,LG Electronics Inc,Mono-c-Si,0,275.0,252.0,1.5876000000000001,1.62,0.98,60.0,9.26,38.7,8.68,31.7,0.002778,-0.11997000000000001,44.2,1.552084434303083,9.270082538841384,1.351785049877559e-10,0.269558519544054,247.56780602288046,8.846070025063558,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1C-L4,LG Electronics Inc,Mono-c-Si,0,275.0,251.5,1.5876000000000001,1.62,0.98,60.0,9.28,38.4,8.8,31.3,0.0027839999999999996,-0.11904,45.6,1.4939422660739894,9.282022296641772,6.357672121019858e-11,0.2961717625422269,1359.0856928270177,2.388937948102075,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1K-B3,LG Electronics Inc,Mono-c-Si,0,275.0,246.2,1.5876000000000001,1.62,0.98,60.0,9.23,38.8,8.63,31.9,0.0036920000000000004,-0.12027999999999998,49.1,1.5757617864618716,9.240964600517929,1.8338971528648105e-10,0.2513579050754892,211.59306990293314,11.462683018955007,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1W-B3,LG Electronics Inc,Mono-c-Si,0,275.0,252.6,1.5876000000000001,1.62,0.98,60.0,9.26,38.7,8.68,31.7,0.002778,-0.11997000000000001,43.7,1.552084434303083,9.270082538841384,1.351785049877559e-10,0.269558519544054,247.56780602288046,8.846070025063558,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1W-G4,LG Electronics Inc,Mono-c-Si,0,275.0,252.0,1.5876000000000001,1.62,0.98,60.0,9.26,38.7,8.68,31.7,0.002778,-0.11997000000000001,44.2,1.552084434303083,9.270082538841384,1.351785049877559e-10,0.269558519544054,247.56780602288046,8.846070025063558,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG275S1W-L4,LG Electronics Inc,Mono-c-Si,0,275.0,251.5,1.5876000000000001,1.62,0.98,60.0,9.28,38.4,8.8,31.3,0.0027839999999999996,-0.11904,45.6,1.4939422660739894,9.282022296641772,6.357672121019858e-11,0.2961717625422269,1359.0856928270177,2.388937948102075,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280N1C-G3,LG Electronics Inc,Mono-c-Si,0,280.0,257.6,1.5876000000000001,1.62,0.98,60.0,9.56,38.9,8.97,31.5,0.002868,-0.1167,43.5,1.5477926453551842,9.57061667151394,1.1472101412184592e-10,0.3103686711019197,279.4778644237323,10.724716921906886,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280N1K-A3,LG Electronics Inc,Mono-c-Si,0,280.0,252.6,1.5876000000000001,1.62,0.98,72.0,9.46,39.3,8.92,31.5,0.003784000000000001,-0.11396999999999997,49.3,1.5138172982048541,9.467183026807774,4.986878914275213e-11,0.36824205572470253,484.97244386688226,7.089163392846373,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280N1K-B3,LG Electronics Inc,Mono-c-Si,0,280.0,250.1,1.5876000000000001,1.62,0.98,60.0,9.46,39.33,8.92,31.49,0.003784000000000001,-0.11405699999999999,50.9,1.5303438831944374,9.466557749954458,6.477036773717332e-11,0.36915473785194375,532.5308447204385,9.364533636433942,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280N1W-G3,LG Electronics Inc,Mono-c-Si,0,280.0,257.6,1.5876000000000001,1.62,0.98,60.0,9.56,38.9,8.97,31.5,0.002868,-0.1167,43.5,1.5477926453551842,9.57061667151394,1.1472101412184592e-10,0.3103686711019197,279.4778644237323,10.724716921906886,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280N9K-G4,LG Electronics Inc,Mono-c-Si,0,280.0,260.8,1.4307999999999998,1.46,0.98,54.0,9.75,36.4,9.07,30.9,0.002925,-0.10192000000000001,43.6,1.4076758814507122,9.760161870004378,5.562847413092294e-11,0.1218870063356649,116.94681391203366,11.865026956062788,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1C-A5,LG Electronics Inc,Mono-c-Si,0,280.0,252.4,1.659336,1.666,0.996,60.0,9.87,37.7,9.31,30.1,0.003948,-0.11687000000000002,47.9,1.487179313990236,9.875400960396679,9.606129809412972e-11,0.3447142524269066,629.9491123688198,5.2016257477890955,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1C-B3,LG Electronics Inc,Mono-c-Si,0,280.0,255.2,1.5876000000000001,1.62,0.98,60.0,9.33,38.8,8.78,31.9,0.0037320000000000005,-0.12027999999999998,45.5,1.5704311732583895,9.336620494843823,1.7182565597284455e-10,0.2493917632578932,351.4579214117299,10.757733508495509,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1C-G4,LG Electronics Inc,Mono-c-Si,0,280.0,256.7,1.5876000000000001,1.62,0.98,60.0,9.33,38.8,8.78,31.9,0.0027990000000000003,-0.12027999999999998,44.2,1.55610373921849,9.337003574215444,1.3680041426123718e-10,0.25285511623472257,336.8477745796057,8.869579009529192,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1C-L4,LG Electronics Inc,Mono-c-Si,0,280.0,256.2,1.5876000000000001,1.62,0.98,60.0,9.39,38.6,8.9,31.5,0.002817,-0.11966,45.6,1.5030275606863184,9.39250495199287,6.573548813057991e-11,0.28937925349484855,1084.75992894348,2.5692154713430915,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1W-A5,LG Electronics Inc,Mono-c-Si,0,280.0,252.4,1.659336,1.666,0.996,60.0,9.87,37.7,9.31,30.1,0.003948,-0.11687000000000002,47.9,1.487179313990236,9.875400960396679,9.606129809412972e-11,0.3447142524269066,629.9491123688198,5.2016257477890955,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1W-B3,LG Electronics Inc,Mono-c-Si,0,280.0,255.2,1.5876000000000001,1.62,0.98,60.0,9.33,38.8,8.78,31.9,0.0037320000000000005,-0.12027999999999998,45.5,1.5704311732583895,9.336620494843823,1.7182565597284455e-10,0.2493917632578932,351.4579214117299,10.757733508495509,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1W-G4,LG Electronics Inc,Mono-c-Si,0,280.0,256.7,1.5876000000000001,1.62,0.98,60.0,9.33,38.8,8.78,31.9,0.0027990000000000003,-0.12027999999999998,44.2,1.55610373921849,9.337003574215444,1.3680041426123718e-10,0.25285511623472257,336.8477745796057,8.869579009529192,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG280S1W-L4,LG Electronics Inc,Mono-c-Si,0,280.0,256.2,1.5876000000000001,1.62,0.98,60.0,9.39,38.6,8.9,31.5,0.002817,-0.11966,45.6,1.5030275606863184,9.39250495199287,6.573548813057991e-11,0.28937925349484855,1084.75992894348,2.5692154713430915,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1C-A3,LG Electronics Inc,Mono-c-Si,0,285.0,259.5,1.5876000000000001,1.62,0.98,60.0,9.59,39.47,9.03,31.63,0.002877,-0.114463,46.3,1.5404025578151357,9.598074959631544,7.079439925864314e-11,0.36124108232978935,429.0179017316541,10.159354163270265,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1C-B3,LG Electronics Inc,Mono-c-Si,0,285.0,258.2,1.5876000000000001,1.62,0.98,60.0,9.59,39.5,9.03,31.6,0.002877,-0.1264,47.9,1.5281277849390287,9.598524094169836,5.649243147652342e-11,0.3713033686765017,417.73348037354,-1.9985867758538594,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1C-G3,LG Electronics Inc,Mono-c-Si,0,285.0,262.3,1.5876000000000001,1.62,0.98,60.0,9.68,39.0,9.09,31.6,0.002904,-0.11699999999999999,43.5,1.5516419112623259,9.689954852639117,1.1602162893614327e-10,0.30488055337894726,296.46284678762544,10.710856218536957,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1K-A3,LG Electronics Inc,Mono-c-Si,0,285.0,257.3,1.5876000000000001,1.62,0.98,72.0,9.59,39.5,9.03,31.6,0.003836,-0.11455,49.3,1.5209953278306347,9.598802529516535,5.003104789163714e-11,0.3729621577301271,406.32721305874674,7.004345613442858,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1K-B3,LG Electronics Inc,Mono-c-Si,0,285.0,254.7,1.5876000000000001,1.62,0.98,60.0,9.59,39.47,9.03,31.63,0.003836,-0.114463,50.9,1.5375553492873948,9.59818233891287,6.750704663503335e-11,0.3619017869239836,424.1621379271836,9.615070306292436,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1W-A3,LG Electronics Inc,Mono-c-Si,0,285.0,259.5,1.5876000000000001,1.62,0.98,60.0,9.59,39.47,9.03,31.63,0.002877,-0.114463,46.3,1.5404025578151357,9.598074959631544,7.079439925864314e-11,0.36124108232978935,429.0179017316541,10.159354163270265,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1W-B3,LG Electronics Inc,Mono-c-Si,0,285.0,258.2,1.5876000000000001,1.62,0.98,60.0,9.59,39.5,9.03,31.6,0.002877,-0.1264,47.9,1.5281277849390287,9.598524094169836,5.649243147652342e-11,0.3713033686765017,417.73348037354,-1.9985867758538594,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285N1W-G3,LG Electronics Inc,Mono-c-Si,0,285.0,262.3,1.5876000000000001,1.62,0.98,60.0,9.68,39.0,9.09,31.6,0.002904,-0.11699999999999999,43.5,1.5516419112623259,9.689954852639117,1.1602162893614327e-10,0.30488055337894726,296.46284678762544,10.710856218536957,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285S1C-A5,LG Electronics Inc,Mono-c-Si,0,285.0,259.3,1.648704,1.662,0.992,60.0,9.92,38.0,9.35,30.5,0.002976,-0.11399999999999999,46.7,1.4690855048233915,9.927840630749944,5.744441263751055e-11,0.3334334114812537,421.86142332381195,4.414854657090308,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285S1C-G4,LG Electronics Inc,Mono-c-Si,0,285.0,261.4,1.5876000000000001,1.62,0.98,60.0,9.38,38.9,8.88,32.1,0.002814,-0.12059,44.2,1.5584375672450042,9.38282345462441,1.3479176438749254e-10,0.23726908921228754,788.248682120899,8.669855687188003,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285S1C-L4,LG Electronics Inc,Mono-c-Si,0,285.0,260.9,1.5876000000000001,1.62,0.98,60.0,9.5,38.8,9.0,31.7,0.00285,-0.12027999999999998,45.6,1.5121105332364935,9.502970141031271,6.793834670704473e-11,0.28273923940080714,904.3419248844575,2.747333889206104,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285S1W-A5,LG Electronics Inc,Mono-c-Si,0,285.0,259.3,1.648704,1.662,0.992,60.0,9.92,38.0,9.35,30.5,0.002976,-0.11399999999999999,46.7,1.4690855048233915,9.927840630749944,5.744441263751055e-11,0.3334334114812537,421.86142332381195,4.414854657090308,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285S1W-G4,LG Electronics Inc,Mono-c-Si,0,285.0,261.4,1.5876000000000001,1.62,0.98,60.0,9.38,38.9,8.88,32.1,0.002814,-0.12059,44.2,1.5584375672450042,9.38282345462441,1.3479176438749254e-10,0.23726908921228754,788.248682120899,8.669855687188003,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG285S1W-L4,LG Electronics Inc,Mono-c-Si,0,285.0,260.9,1.5876000000000001,1.62,0.98,60.0,9.5,38.8,9.0,31.7,0.00285,-0.12027999999999998,45.6,1.5121105332364935,9.502970141031271,6.793834670704473e-11,0.28273923940080714,904.3419248844575,2.747333889206104,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1C-A3,LG Electronics Inc,Mono-c-Si,0,290.0,265.1,1.5876000000000001,1.62,0.98,60.0,9.7,39.6,9.15,31.8,0.0029099999999999994,-0.11484,46.6,1.5123259873951629,9.707485766459236,4.086378063974908e-11,0.35755623165769285,463.31872546962404,5.3013575094634735,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1C-B3,LG Electronics Inc,Mono-c-Si,0,290.0,262.9,1.5876000000000001,1.62,0.98,60.0,9.7,39.6,9.15,31.8,0.0029099999999999994,-0.12672,47.9,1.5337794732767958,9.706692799889,5.898286371428716e-11,0.35261036028217635,511.0448244476903,-1.753745204927047,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1C-G3,LG Electronics Inc,Mono-c-Si,0,290.0,267.0,1.5876000000000001,1.62,0.98,60.0,9.8,39.2,9.19,31.8,0.00294,-0.1176,43.5,1.5617129658446294,9.811280870397859,1.2130980293480035e-10,0.29782174708269454,258.72589531893755,11.004217103451534,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1K-A3,LG Electronics Inc,Mono-c-Si,0,290.0,261.9,1.5876000000000001,1.62,0.98,72.0,9.7,39.6,9.15,31.8,0.0038799999999999998,-0.11484,49.3,1.5265977095484253,9.706955934933628,5.222364428041454e-11,0.35426304349682913,494.0172348807456,7.270324616537524,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1K-B3,LG Electronics Inc,Mono-c-Si,0,290.0,259.3,1.5876000000000001,1.62,0.98,60.0,9.85,39.68,9.28,31.83,0.00394,-0.115072,50.9,1.5461425976551066,9.857793036743189,6.984509812810751e-11,0.35020751293462093,442.64442385818916,9.67759355874919,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1K-Z4,LG Electronics Inc,Mono-c-Si,0,290.0,269.7,1.5876000000000001,1.62,0.98,60.0,9.61,38.9,9.16,31.7,0.0028829999999999997,-0.10892000000000002,43.5,1.4563470088749773,9.610002876448512,2.4122730827008978e-11,0.2992981279761962,999993.2189226763,4.5939772905188105,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG290N1T-A4,LG Electronics Inc,Mono-c-Si,1,290.0,265.8,1.6365999999999998,1.67,0.98,60.0,9.61,39.5,9.04,32.1,0.0028829999999999997,-0.10665000000000001,48.1,1.4488274688359246,9.6224671507221,1.3671791684904165e-11,0.32815672616854646,252.95163816701378,3.676575994409094,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1W-A3,LG Electronics Inc,Mono-c-Si,0,290.0,265.1,1.5876000000000001,1.62,0.98,72.0,9.7,39.6,9.15,31.8,0.0029099999999999994,-0.11484,46.6,1.5123259873951629,9.707485766459236,4.086378063974908e-11,0.35755623165769285,463.31872546962404,5.3013575094634735,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1W-B3,LG Electronics Inc,Mono-c-Si,0,290.0,262.9,1.5876000000000001,1.62,0.98,60.0,9.7,39.6,9.15,31.8,0.0029099999999999994,-0.12672,47.9,1.5337794732767958,9.706692799889,5.898286371428716e-11,0.35261036028217635,511.0448244476903,-1.753745204927047,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290N1W-G3,LG Electronics Inc,Mono-c-Si,0,290.0,267.0,1.5876000000000001,1.62,0.98,60.0,9.8,39.2,9.19,31.8,0.00294,-0.1176,43.5,1.5617129658446294,9.811280870397859,1.2130980293480035e-10,0.29782174708269454,258.72589531893755,11.004217103451534,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290S1C-A5,LG Electronics Inc,Mono-c-Si,0,290.0,264.0,1.648704,1.662,0.992,60.0,9.97,38.3,9.36,31.0,0.002991,-0.1149,46.7,1.4902769933036668,9.98180018264652,6.781087989250036e-11,0.3022012282482239,255.33048508519607,5.793104211181232,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290S1C-G4,LG Electronics Inc,Mono-c-Si,0,290.0,266.2,1.5876000000000001,1.62,0.98,60.0,9.43,39.0,8.98,32.3,0.002829,-0.12090000000000001,44.2,1.5618508874626527,9.442760138187031,1.3508332603633984e-10,0.22156670594184863,999999.9297525707,8.612953139651221,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG290S1C-L4,LG Electronics Inc,Mono-c-Si,0,290.0,265.6,1.5876000000000001,1.62,0.98,60.0,9.61,39.0,9.1,31.9,0.0028829999999999997,-0.12090000000000001,45.6,1.5211912320562984,9.613418136202315,7.018548947951379e-11,0.27624665577506696,776.6602799096923,2.9233355823398974,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290S1W-A5,LG Electronics Inc,Mono-c-Si,0,290.0,264.0,1.648704,1.662,0.992,60.0,9.97,38.3,9.36,31.0,0.002991,-0.1149,46.7,1.4902769933036668,9.98180018264652,6.781087989250036e-11,0.3022012282482239,255.33048508519607,5.793104211181232,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG290S1W-G4,LG Electronics Inc,Mono-c-Si,0,290.0,266.2,1.5876000000000001,1.62,0.98,60.0,9.43,39.0,8.98,32.3,0.002829,-0.12090000000000001,44.2,1.5618508874626527,9.442760138187031,1.3508332603633984e-10,0.22156670594184863,999999.9297525707,8.612953139651221,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG290S1W-L4,LG Electronics Inc,Mono-c-Si,0,290.0,265.6,1.5876000000000001,1.62,0.98,60.0,9.61,39.0,9.1,31.9,0.0028829999999999997,-0.12090000000000001,45.6,1.5211912320562984,9.613418136202315,7.018548947951379e-11,0.27624665577506696,776.6602799096923,2.9233355823398974,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295A1C-B3,LG Electronics Inc,Mono-c-Si,0,295.0,267.6,1.5876000000000001,1.62,0.98,60.0,9.85,39.68,9.28,31.83,0.002955,-0.115072,47.9,1.5322182962957098,9.858323940073078,5.52888645703612e-11,0.35336040028809934,418.14334476798496,7.761754473033369,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295A1W-B3,LG Electronics Inc,Mono-c-Si,0,295.0,267.6,1.5876000000000001,1.62,0.98,60.0,9.85,39.68,9.28,31.83,0.002955,-0.115072,47.9,1.5322182962957098,9.858323940073078,5.52888645703612e-11,0.35336040028809934,418.14334476798496,7.761754473033369,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1C-A3,LG Electronics Inc,Mono-c-Si,0,295.0,269.8,1.5876000000000001,1.62,0.98,60.0,9.85,39.7,9.28,31.8,0.002955,-0.11513,46.6,1.5150278460025939,9.858975270045814,4.065447879546244e-11,0.36313807605473625,398.529535812337,5.132080085787909,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1C-B3,LG Electronics Inc,Mono-c-Si,0,295.0,267.6,1.5876000000000001,1.62,0.98,60.0,9.85,39.7,9.28,31.8,0.002955,-0.12704000000000001,47.9,1.5364906659578201,9.858131382695028,5.86680196503865e-11,0.3582678503603422,433.9899726787857,-1.9132595343809569,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1C-G3,LG Electronics Inc,Mono-c-Si,0,295.0,271.8,1.5876000000000001,1.62,0.98,60.0,9.94,39.3,9.34,31.8,0.002982,-0.11789999999999998,43.5,1.5619266523082143,9.949688106092118,1.1611839399437396e-10,0.3046013644830445,312.52112129531605,10.479709908161265,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1C-G4,LG Electronics Inc,Mono-c-Si,0,295.0,268.6,1.5876000000000001,1.62,0.98,60.0,9.87,39.5,9.28,31.8,0.0029609999999999997,-0.11060000000000002,48.8,1.4775886591254046,9.882565263564276,2.3911231537595473e-11,0.34868860917446004,273.8945041464553,4.343725138971079,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1K-A3,LG Electronics Inc,Mono-c-Si,0,295.0,266.6,1.5876000000000001,1.62,0.98,72.0,9.85,39.7,9.28,31.8,0.00394,-0.11513,49.3,1.5293111008478184,9.858411312391835,5.1953243285718914e-11,0.3598940527037098,421.45107148201754,7.097025621839285,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1K-B3,LG Electronics Inc,Mono-c-Si,0,295.0,264.0,1.5876000000000001,1.62,0.98,60.0,9.98,39.82,9.4,31.98,0.003992,-0.115478,50.9,1.5527788554459812,9.988195750530865,7.212958117358116e-11,0.3421900631857345,416.6863130768932,9.847675612011837,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1K-G4,LG Electronics Inc,Mono-c-Si,0,295.0,275.1,1.5876000000000001,1.62,0.98,60.0,9.66,39.3,9.21,32.1,0.002898,-0.10611,43.9,1.436373834277405,9.660003520586383,1.2659969571381607e-11,0.3040338611565206,834246.861437172,2.9338562836112505,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1K-Z4,LG Electronics Inc,Mono-c-Si,0,295.0,274.5,1.5876000000000001,1.62,0.98,60.0,9.66,39.3,9.21,32.1,0.002898,-0.11004,43.5,1.4729426835281159,9.660002814405118,2.4971330386518314e-11,0.2913268413337903,999993.1427486076,4.842101373676366,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG295N1T-A4,LG Electronics Inc,Mono-c-Si,1,295.0,270.5,1.6365999999999998,1.67,0.98,60.0,9.65,39.9,9.08,32.5,0.002895,-0.10773,48.1,1.4650339114089541,9.662075152062098,1.4127380215832935e-11,0.32057489141246126,256.1912013335286,3.9169019843010124,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1W-A3,LG Electronics Inc,Mono-c-Si,0,295.0,269.8,1.5876000000000001,1.62,0.98,72.0,9.85,39.7,9.28,31.8,0.002955,-0.11513,46.6,1.5150278460025939,9.858975270045814,4.065447879546244e-11,0.36313807605473625,398.529535812337,5.132080085787909,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1W-B3,LG Electronics Inc,Mono-c-Si,0,295.0,267.6,1.5876000000000001,1.62,0.98,60.0,9.85,39.7,9.28,31.8,0.002955,-0.12704000000000001,47.9,1.5364906659578201,9.858131382695028,5.86680196503865e-11,0.3582678503603422,433.9899726787857,-1.9132595343809569,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1W-G3,LG Electronics Inc,Mono-c-Si,0,295.0,271.8,1.5876000000000001,1.62,0.98,60.0,9.94,39.3,9.34,31.8,0.002982,-0.11789999999999998,43.5,1.5619266523082143,9.949688106092118,1.1611839399437396e-10,0.3046013644830445,312.52112129531605,10.479709908161265,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295N1W-G4,LG Electronics Inc,Mono-c-Si,0,295.0,268.6,1.5876000000000001,1.62,0.98,60.0,9.87,39.5,9.28,31.8,0.0029609999999999997,-0.11060000000000002,48.8,1.4775886591254046,9.882565263564276,2.3911231537595473e-11,0.34868860917446004,273.8945041464553,4.343725138971079,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295S1C-A5,LG Electronics Inc,Mono-c-Si,0,295.0,268.7,1.648704,1.662,0.992,60.0,10.02,38.6,9.43,31.3,0.003006,-0.1158,46.7,1.501598910356209,10.029341748548958,6.79251932510239e-11,0.29599041157519473,317.4806206487707,5.755569503396586,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295S1C-G4,LG Electronics Inc,Mono-c-Si,0,295.0,266.3,1.5876000000000001,1.62,0.98,60.0,9.48,39.1,9.08,32.5,0.002844,-0.1173,48.4,1.5540013181038066,9.480001755005073,1.1209510619670174e-10,0.185102174705444,999998.9946069032,10.544632832203947,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG295S1W-A5,LG Electronics Inc,Mono-c-Si,0,295.0,268.7,1.648704,1.662,0.992,60.0,10.02,38.6,9.43,31.3,0.003006,-0.1158,46.7,1.501598910356209,10.029341748548958,6.79251932510239e-11,0.29599041157519473,317.4806206487707,5.755569503396586,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG295S1W-G4,LG Electronics Inc,Mono-c-Si,0,295.0,266.3,1.5876000000000001,1.62,0.98,60.0,9.48,39.1,9.08,32.5,0.002844,-0.1173,48.4,1.5540013181038066,9.480001755005073,1.1209510619670174e-10,0.185102174705444,999998.9946069032,10.544632832203947,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG300A1C-B3,LG Electronics Inc,Mono-c-Si,0,300.0,272.3,1.5876000000000001,1.62,0.98,60.0,9.98,39.82,9.4,31.98,0.0029939999999999997,-0.115478,47.9,1.5387859660822787,9.98872984958805,5.70989664942958e-11,0.3453211484245266,394.7725806875898,7.928953271427099,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300A1W-B3,LG Electronics Inc,Mono-c-Si,0,300.0,272.3,1.5876000000000001,1.62,0.98,60.0,9.98,39.82,9.4,31.98,0.0029939999999999997,-0.115478,47.9,1.5387859660822787,9.98872984958805,5.70989664942958e-11,0.3453211484245266,394.7725806875898,7.928953271427099,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1C-A3,LG Electronics Inc,Mono-c-Si,0,300.0,274.5,1.5876000000000001,1.62,0.98,60.0,9.98,39.8,9.4,32.0,0.0029939999999999997,-0.11541999999999998,46.6,1.5220505304313257,9.98937427429905,4.34966788365324e-11,0.34446958074200423,366.7277533398898,5.596426446829607,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1C-B3,LG Electronics Inc,Mono-c-Si,0,300.0,272.3,1.5876000000000001,1.62,0.98,60.0,9.98,39.8,9.4,32.0,0.0029939999999999997,-0.12736,47.9,1.543692367800121,9.988545150162942,6.280434124505698e-11,0.3396066804394817,396.63138597461773,-1.476284596459921,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1C-G3,LG Electronics Inc,Mono-c-Si,0,300.0,276.5,1.5876000000000001,1.62,0.98,60.0,10.05,39.5,9.46,32.0,0.003015,-0.1185,43.5,1.5695047165163873,10.058038320242414,1.1693586590699834e-10,0.29811329521963886,372.71953029132715,10.437369536982967,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1C-G4,LG Electronics Inc,Mono-c-Si,0,300.0,279.6,1.5876000000000001,1.62,0.98,60.0,9.9,39.8,9.34,32.2,0.00297,-0.10746,43.2,1.4883829463643852,9.90884639148781,2.38816751623022e-11,0.3308477465481024,370.2518441175712,8.175015836710974,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1C-Z4,LG Electronics Inc,Mono-c-Si,0,300.0,278.4,1.5876000000000001,1.62,0.98,60.0,9.9,39.8,9.34,32.2,0.00297,-0.10746,44.8,1.4714778081313555,9.909470705166306,1.755482807846823e-11,0.3347439064823494,349.9174280817161,5.522568330621476,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1K-G4,LG Electronics Inc,Mono-c-Si,0,300.0,279.9,1.5876000000000001,1.62,0.98,60.0,9.7,39.7,9.26,32.5,0.0029099999999999994,-0.10719000000000001,43.9,1.4531492472837004,9.700002833772624,1.3239025732303425e-11,0.2921331876560676,999999.7666431634,3.2727598829235327,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG300N1K-Z4,LG Electronics Inc,Mono-c-Si,0,300.0,279.2,1.5876000000000001,1.62,0.98,60.0,9.7,39.7,9.26,32.5,0.0029099999999999994,-0.11116000000000002,43.5,1.490200659765078,9.700002713775783,2.6113061158723048e-11,0.2797566706467553,999999.762688469,5.185623410260166,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG300N1T-A4,LG Electronics Inc,Mono-c-Si,1,300.0,275.2,1.6365999999999998,1.67,0.98,60.0,9.69,40.3,9.12,32.9,0.002907,-0.10881,48.1,1.48123566458321,9.701689179625978,1.4587590944159163e-11,0.3130643875018716,259.5215436429724,4.151760374954943,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1W-A3,LG Electronics Inc,Mono-c-Si,0,300.0,274.5,1.5876000000000001,1.62,0.98,72.0,9.98,39.8,9.4,32.0,0.0029939999999999997,-0.11541999999999998,46.6,1.5220505304313257,9.98937427429905,4.34966788365324e-11,0.34446958074200423,366.7277533398898,5.596426446829607,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1W-B3,LG Electronics Inc,Mono-c-Si,0,300.0,272.3,1.5876000000000001,1.62,0.98,60.0,9.98,39.8,9.4,32.0,0.0029939999999999997,-0.12736,47.9,1.543692367800121,9.988545150162942,6.280434124505698e-11,0.3396066804394817,396.63138597461773,-1.476284596459921,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1W-G3,LG Electronics Inc,Mono-c-Si,0,300.0,276.5,1.5876000000000001,1.62,0.98,60.0,10.05,39.5,9.46,32.0,0.003015,-0.1185,43.5,1.5695047165163873,10.058038320242414,1.1693586590699834e-10,0.29811329521963886,372.71953029132715,10.437369536982967,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300N1W-G4,LG Electronics Inc,Mono-c-Si,0,300.0,279.6,1.5876000000000001,1.62,0.98,60.0,9.9,39.8,9.34,32.2,0.00297,-0.10746,43.2,1.4883829463643852,9.90884639148781,2.38816751623022e-11,0.3308477465481024,370.2518441175712,8.175015836710974,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300S1C-A5,LG Electronics Inc,Mono-c-Si,0,300.0,273.4,1.648704,1.662,0.992,60.0,10.07,38.9,9.47,31.7,0.0030210000000000002,-0.1167,46.7,1.5178752784022125,10.079828226385695,7.369706243425025e-11,0.27751535915701747,284.3422270094194,6.413250366379296,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG300S1W-A5,LG Electronics Inc,Mono-c-Si,0,300.0,273.4,1.648704,1.662,0.992,60.0,10.07,38.9,9.47,31.7,0.0030210000000000002,-0.1167,46.7,1.5178752784022125,10.079828226385695,7.369706243425025e-11,0.27751535915701747,284.3422270094194,6.413250366379296,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305A1C-B3,LG Electronics Inc,Mono-c-Si,0,305.0,276.9,1.5876000000000001,1.62,0.98,60.0,10.1,40.0,9.52,32.1,0.0030299999999999997,-0.11599999999999999,47.9,1.5445648800494252,10.108005186822567,5.6711358898167856e-11,0.34574218897762315,436.21671788733613,7.762883611312008,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305A1W-B3,LG Electronics Inc,Mono-c-Si,0,305.0,276.9,1.5876000000000001,1.62,0.98,60.0,10.1,40.0,9.52,32.1,0.0030299999999999997,-0.11599999999999999,47.9,1.5445648800494252,10.108005186822567,5.6711358898167856e-11,0.34574218897762315,436.21671788733613,7.762883611312008,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1C-B3,LG Electronics Inc,Mono-c-Si,0,305.0,276.9,1.5876000000000001,1.62,0.98,60.0,10.1,40.0,9.52,32.1,0.0030299999999999997,-0.128,47.9,1.5493034427762893,10.10782272408156,6.139601097817269e-11,0.3446948262653352,445.0390809811767,-1.7535322545057446,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1C-G4,LG Electronics Inc,Mono-c-Si,0,305.0,284.4,1.5876000000000001,1.62,0.98,60.0,9.93,40.1,9.39,32.5,0.002979,-0.10827000000000002,43.2,1.4993223735904382,9.936483470921138,2.389533131219881e-11,0.3251964072253362,498.06661488525197,8.144055428597573,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1C-Z4,LG Electronics Inc,Mono-c-Si,0,305.0,283.1,1.5876000000000001,1.62,0.98,60.0,9.93,40.1,9.39,32.5,0.002979,-0.10827000000000002,44.8,1.4822959841480354,9.937071045868747,1.7564798787009128e-11,0.32910300682294524,462.16542565041976,5.492193540500843,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1K-G4,LG Electronics Inc,Mono-c-Si,0,305.0,284.7,1.5876000000000001,1.62,0.98,60.0,9.74,40.1,9.28,32.9,0.002922,-0.10827000000000002,43.9,1.4691277108775962,9.740788671940267,1.3613786901162582e-11,0.28955871021396873,3576.0139862000055,3.4760027610611464,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1K-Z4,LG Electronics Inc,Mono-c-Si,0,305.0,284.0,1.5876000000000001,1.62,0.98,60.0,9.74,40.1,9.28,32.9,0.002922,-0.11228000000000002,43.5,1.505383050309617,9.740003425852372,2.6298685516411444e-11,0.2810637219347801,799120.5839728334,5.210797406125583,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1T-A4,LG Electronics Inc,Mono-c-Si,1,305.0,279.9,1.6365999999999998,1.67,0.98,60.0,9.73,40.7,9.16,33.3,0.002919,-0.10989000000000002,48.1,1.4974328177750424,9.741309411622915,1.5052271553359294e-11,0.30562413180371595,262.94231092288345,4.381326959340873,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1T-A5,LG Electronics Inc,Mono-c-Si,0,305.0,280.5,1.706,1.706,1.0,60.0,10.04,40.6,9.37,32.6,0.002008,-0.10962000000000001,47.3,1.4697047680853912,10.063978064882722,9.868832806585e-12,0.37531188181569425,157.1490998327089,0.7849840707954747,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1W-B3,LG Electronics Inc,Mono-c-Si,0,305.0,276.9,1.5876000000000001,1.62,0.98,60.0,10.1,40.0,9.52,32.1,0.0030299999999999997,-0.128,47.9,1.5493034427762893,10.10782272408156,6.139601097817269e-11,0.3446948262653352,445.0390809811767,-1.7535322545057446,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305N1W-G4,LG Electronics Inc,Mono-c-Si,0,305.0,284.4,1.5876000000000001,1.62,0.98,60.0,9.93,40.1,9.39,32.5,0.002979,-0.10827000000000002,43.2,1.4993223735904382,9.936483470921138,2.389533131219881e-11,0.3251964072253362,498.06661488525197,8.144055428597573,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305S1C-A5,LG Electronics Inc,Mono-c-Si,0,305.0,278.1,1.648704,1.662,0.992,60.0,10.12,39.2,9.54,32.0,0.0030359999999999996,-0.1176,46.7,1.5291612922380422,10.127612026908636,7.37396869080095e-11,0.2715798524247719,361.0586607118324,6.366484686664645,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG305S1W-A5,LG Electronics Inc,Mono-c-Si,0,305.0,278.1,1.648704,1.662,0.992,60.0,10.12,39.2,9.54,32.0,0.0030359999999999996,-0.1176,46.7,1.5291612922380422,10.127612026908636,7.37396869080095e-11,0.2715798524247719,361.0586607118324,6.366484686664645,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1C-B3,LG Electronics Inc,Mono-c-Si,0,310.0,281.6,1.5876000000000001,1.62,0.98,60.0,10.19,40.1,9.61,32.3,0.0030569999999999994,-0.12832000000000002,47.9,1.5558863138925887,10.197332047023163,6.480549357724627e-11,0.3279386955395375,455.76571798023895,-1.3969617952133477,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1C-G4,LG Electronics Inc,Mono-c-Si,0,310.0,289.1,1.5876000000000001,1.62,0.98,60.0,9.96,40.4,9.45,32.8,0.002988,-0.10908,43.2,1.50949986403542,9.963169340743496,2.3618712438671273e-11,0.31959040793378324,1004.3478726928032,8.00193060309625,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1C-V5,LG Electronics Inc,Mono-c-Si,0,310.0,287.6,1.648704,,,60.0,10.29,40.5,9.67,32.1,0.002720676,-0.10481399999999999,45.95,1.441520658838357,10.307415904908863,6.3756472744504114e-12,0.41720966512571867,246.5038426653905,1.1679077422626936,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1C-Z4,LG Electronics Inc,Mono-c-Si,0,310.0,287.9,1.5876000000000001,1.62,0.98,60.0,9.96,40.4,9.45,32.8,0.002988,-0.10908,44.8,1.492367582750527,9.963708168260844,1.7360795289270497e-11,0.32349874762908787,868.9054556887088,5.352846897726974,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1K-A5,LG Electronics Inc,Mono-c-Si,0,310.0,285.2,1.648704,1.662,0.992,60.0,10.11,40.6,9.55,32.5,0.002022,-0.10556000000000001,47.7,1.4529165015610563,10.119924912083409,7.326196356541508e-12,0.3852203266151331,392.4042357936734,2.061777885106622,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1K-G4,LG Electronics Inc,Mono-c-Si,0,310.0,289.5,1.5876000000000001,1.62,0.98,60.0,9.78,40.5,9.31,33.3,0.002934,-0.10935000000000002,43.9,1.4859827737078068,9.781651004072,1.421589792725646e-11,0.2823719850812698,1672.6779719570047,3.8094102338425007,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1K-L5,LG Electronics Inc,Mono-c-Si,0,310.0,287.8,1.7254999999999998,,,60.0,10.36,40.3,9.94,31.2,0.00259518,-0.10409489999999998,45.83,1.4061513323837935,10.360005407078077,3.703138956030023e-12,0.46202580738698934,885262.2711344507,-3.122588323853361,-0.3433,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG310N1K-V5,LG Electronics Inc,Mono-c-Si,0,310.0,284.6,1.648704,,,60.0,10.11,40.6,9.55,32.5,0.0036395999999999993,-0.105966,48.5,1.4703984474353398,10.119183127462936,1.0219383979483626e-11,0.3812744370445532,419.75728934991406,4.230506015917866,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1K-Z4,LG Electronics Inc,Mono-c-Si,0,310.0,288.8,1.5876000000000001,1.62,0.98,60.0,9.78,40.5,9.31,33.3,0.002934,-0.11340000000000001,43.5,1.522535357153384,9.780765111658003,2.738204702347695e-11,0.2738154510087996,3500.031373307981,5.522998206904576,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1T-A4,LG Electronics Inc,Mono-c-Si,1,310.0,284.6,1.6365999999999998,1.67,0.98,60.0,9.77,41.1,9.2,33.7,0.0029309999999999996,-0.11097000000000001,48.1,1.513625448201222,9.780936002054709,1.552126998805092e-11,0.2982530708972117,266.453180365356,4.605767286670047,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1T-A5,LG Electronics Inc,Mono-c-Si,0,310.0,285.2,1.706,1.706,1.0,60.0,10.08,40.7,9.38,33.1,0.002016,-0.10989000000000002,47.3,1.4849354015203695,10.10457763719649,1.2238143997703189e-11,0.3232585670775425,132.57769012650624,2.5411455039020185,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1T-L5,LG Electronics Inc,Mono-c-Si,1,310.0,286.0,1.7254999999999998,,,60.0,10.22,40.6,9.61,32.3,0.0034318760000000004,-0.10945760000000002,46.5,1.4796989889607082,10.234734364795665,1.2235828659576947e-11,0.3992845410080316,276.95038882504184,2.3331117824889587,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1T-V5,LG Electronics Inc,Mono-c-Si,1,310.0,285.1,1.65,,,60.0,10.14,40.2,9.52,32.6,0.0039039,-0.10452000000000002,48.5,1.4612215135621551,10.155917571957728,1.1231435548185997e-11,0.3278964210476543,208.8804585768935,5.413208904297006,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1W-B3,LG Electronics Inc,Mono-c-Si,0,310.0,281.6,1.5876000000000001,1.62,0.98,60.0,10.19,40.1,9.61,32.3,0.0030569999999999994,-0.12832000000000002,47.9,1.5558863138925887,10.197332047023163,6.480549357724627e-11,0.3279386955395375,455.76571798023895,-1.3969617952133477,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1W-G4,LG Electronics Inc,Mono-c-Si,0,310.0,289.1,1.5876000000000001,1.62,0.98,60.0,9.96,40.4,9.45,32.8,0.002988,-0.10908,43.2,1.50949986403542,9.963169340743496,2.3618712438671273e-11,0.31959040793378324,1004.3478726928032,8.00193060309625,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG310N1W-V5,LG Electronics Inc,Mono-c-Si,0,310.0,287.6,1.648704,,,60.0,10.29,40.5,9.67,32.1,0.002720676,-0.10481399999999999,45.95,1.441520658838357,10.307415904908863,6.3756472744504114e-12,0.41720966512571867,246.5038426653905,1.1679077422626936,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315E1K-A5,LG Electronics Inc,Mono-c-Si,0,315.0,290.0,1.65,,,60.0,10.15,40.7,9.58,32.9,0.003045,-0.10582000000000001,47.7,1.4777296327116822,10.160254639398671,1.0972473409530208e-11,0.3431460994710974,339.6446047262485,5.296104052791926,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1C-G4,LG Electronics Inc,Mono-c-Si,0,315.0,293.9,1.5876000000000001,1.62,0.98,60.0,10.02,40.6,9.5,33.2,0.003006,-0.10962000000000001,43.2,1.5230582951932892,10.024124666016638,2.6400035965128242e-11,0.29035202326644727,705.348595145853,8.929577283111033,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1C-L5,LG Electronics Inc,Mono-c-Si,0,315.0,291.6,1.7254999999999998,,,60.0,10.48,40.4,10.07,31.3,0.002437648,-0.1043936,46.48,1.4139788015490444,10.480005174218887,4.0903442227991985e-12,0.4485687661459951,908562.1135953321,-2.434992145527267,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG315N1C-V5,LG Electronics Inc,Mono-c-Si,0,315.0,292.4,1.648704,,,60.0,10.33,40.6,9.7,32.5,0.0027312520000000004,-0.1050728,45.95,1.4526887377416844,10.34792231290839,7.400040963028658e-12,0.37855372404667514,218.18947310117414,2.378198557730963,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1C-Z4,LG Electronics Inc,Mono-c-Si,0,315.0,292.7,1.5876000000000001,1.62,0.98,60.0,10.02,40.6,9.5,33.2,0.003006,-0.10962000000000001,44.8,1.505722701074907,10.024630341676364,1.9411983253416883e-11,0.29430829544939785,636.8793928802311,6.2624525087549205,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1K-A5,LG Electronics Inc,Mono-c-Si,0,315.0,289.9,1.648704,1.662,0.992,60.0,10.15,40.7,9.58,32.9,0.00203,-0.10582000000000001,47.7,1.4640378010394817,10.160788256900378,8.476998289242379e-12,0.3462529612430896,325.7678804775331,3.252751099364539,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1K-G4,LG Electronics Inc,Mono-c-Si,0,315.0,294.3,1.5876000000000001,1.62,0.98,60.0,9.82,40.6,9.35,33.7,0.0029460000000000003,-0.10962000000000001,43.9,1.4965810586374846,9.821841413129196,1.6182534479475027e-11,0.24286548949544337,1295.1679048049086,4.871336415151955,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1K-L5,LG Electronics Inc,Mono-c-Si,0,315.0,292.6,1.7254999999999998,,,60.0,10.4,40.4,9.97,31.6,0.0026052000000000002,-0.10435319999999998,45.83,1.4149158262505124,10.400004978358853,4.1366563231639015e-12,0.4305201431501321,899391.3992689768,-2.27117301288162,-0.3433,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG315N1K-V5,LG Electronics Inc,Mono-c-Si,0,315.0,289.3,1.65,,,60.0,10.15,40.7,9.58,32.9,0.00370475,-0.10643050000000001,48.5,1.4834982869467561,10.160032403967763,1.2215198694114715e-11,0.34184038034270553,345.8473130929854,5.5151727105935695,-0.3535,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1K-Z4,LG Electronics Inc,Mono-c-Si,0,315.0,293.6,1.5876000000000001,1.62,0.98,60.0,9.82,40.6,9.35,33.7,0.0029460000000000003,-0.11368000000000002,43.5,1.5313526368514636,9.820005428938538,3.00518559397465e-11,0.23465757525130393,424200.06398616964,6.277912346828707,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1T-A4,LG Electronics Inc,Mono-c-Si,1,315.0,289.4,1.6365999999999998,1.67,0.98,60.0,9.81,41.5,9.24,34.1,0.0029430000000000003,-0.11205000000000001,48.1,1.529813632304899,9.820569074802792,1.599443764946612e-11,0.2909501763215911,270.0540309036315,4.825239551422641,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +LG Electronics Inc LG315N1T-A5,LG Electronics Inc,Mono-c-Si,0,315.0,289.9,1.706,1.706,1.0,60.0,10.12,40.8,9.41,33.5,0.002024,-0.11016,47.3,1.4964277016464536,10.142864065060705,1.4158294385648693e-11,0.2836990122599374,125.56970973942106,3.7307044328289902,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1T-L5,LG Electronics Inc,Mono-c-Si,1,315.0,290.7,1.7254999999999998,,,60.0,10.26,40.7,9.67,32.6,0.003445308,-0.10972720000000001,46.5,1.486879068450185,10.271644411913014,1.3137571898228331e-11,0.3720370988940745,327.8053640640767,2.8854766494686652,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1T-V5,LG Electronics Inc,Mono-c-Si,1,315.0,289.9,1.65,,,60.0,10.18,40.3,9.58,32.9,0.0039193,-0.10478,48.5,1.4681766324646985,10.19288549185529,1.2024322753632732e-11,0.3009963152778345,237.79786927942774,5.957688921106633,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1W-G4,LG Electronics Inc,Mono-c-Si,0,315.0,293.9,1.5876000000000001,1.62,0.98,60.0,10.02,40.6,9.5,33.2,0.003006,-0.10962000000000001,43.2,1.5230582951932892,10.024124666016638,2.6400035965128242e-11,0.29035202326644727,705.348595145853,8.929577283111033,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG315N1W-L5,LG Electronics Inc,Mono-c-Si,0,315.0,291.6,1.7254999999999998,,,60.0,10.48,40.4,10.07,31.3,0.002437648,-0.1043936,46.48,1.4139788015490444,10.480005174218887,4.0903442227991985e-12,0.4485687661459951,908562.1135953321,-2.434992145527267,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG315N1W-V5,LG Electronics Inc,Mono-c-Si,0,315.0,292.4,1.648704,,,60.0,10.33,40.6,9.7,32.5,0.0027312520000000004,-0.1050728,45.95,1.4526887377416844,10.34792231290839,7.400040963028658e-12,0.37855372404667514,218.18947310117414,2.378198557730963,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320E1K-A5,LG Electronics Inc,Mono-c-Si,0,320.0,294.7,1.65,,,60.0,10.19,40.8,9.62,33.3,0.0030569999999999994,-0.10608,47.7,1.4883376935981818,10.199664780046033,1.2524667153974382e-11,0.3043932217080229,320.9350800413393,6.400930066789884,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1C-A5,LG Electronics Inc,Mono-c-Si,0,320.0,296.8,1.648704,1.662,0.992,60.0,10.37,40.7,9.74,32.9,0.003111,-0.10582000000000001,45.9,1.4810542750710554,10.385981332164638,1.185705532377639e-11,0.3361242068227783,218.10497604928068,5.797976872848162,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1C-G4,LG Electronics Inc,Mono-c-Si,0,320.0,298.7,1.5876000000000001,1.62,0.98,60.0,10.05,40.9,9.53,33.6,0.003015,-0.11043,43.2,1.5378112788834504,10.054058535950796,2.8126655041365088e-11,0.27288141753061135,675.7260188172446,9.462126840318797,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1C-L5,LG Electronics Inc,Mono-c-Si,0,320.0,296.4,1.7254999999999998,,,60.0,10.52,40.5,10.1,31.7,0.002446952,-0.10465200000000001,46.48,1.4227797578718797,10.520004921125938,4.567161547313185e-12,0.41756703353799157,892659.5195134262,-1.581968249693608,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG320N1C-N5,LG Electronics Inc,Mono-c-Si,0,320.0,298.4,1.7254999999999998,,,60.0,10.53,40.8,10.04,31.9,0.003329586,-0.10501920000000001,44.94,1.4334730055375307,10.530004722510785,4.585518889692002e-12,0.44846829388850695,999995.6385228432,-1.291397362057059,-0.342,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG320N1C-V5,LG Electronics Inc,Mono-c-Si,0,320.0,297.2,1.648704,,,60.0,10.37,40.7,9.74,32.9,0.002741828,-0.1053316,45.95,1.4631760564042806,10.386755870814186,8.470253343263948e-12,0.34012082874074795,210.49655080812585,3.479491646060149,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1C-Z4,LG Electronics Inc,Mono-c-Si,0,320.0,297.4,1.5876000000000001,1.62,0.98,60.0,10.05,40.9,9.53,33.6,0.003015,-0.11043,44.8,1.5202798328548721,10.054535516708814,2.068586889242775e-11,0.27688359776944005,613.5310269140222,6.78466734933652,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1C-Z5,LG Electronics Inc,Mono-c-Si,0,320.0,295.6,1.654016,1.664,0.994,60.0,10.37,40.7,9.74,32.9,0.003111,-0.10582000000000001,46.6,1.4914389971278814,10.385538422019549,1.4362296738040504e-11,0.3338111071251884,222.77817063240641,7.452104617918546,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1K-A5,LG Electronics Inc,Mono-c-Si,0,320.0,294.7,1.648704,1.662,0.992,60.0,10.19,40.8,9.62,33.3,0.002038,-0.10608,47.7,1.474466135775614,10.200150075914257,9.6731289325762e-12,0.3075510777704187,308.76079459774394,4.333593060954384,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1K-G4,LG Electronics Inc,Mono-c-Si,0,320.0,299.0,1.5876000000000001,1.62,0.98,60.0,9.86,40.9,9.39,34.1,0.0029579999999999997,-0.11043,43.9,1.5108471419547065,9.861808582337336,1.7208474004072035e-11,0.22522169507552275,1227.8600416952513,5.359917182502518,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1K-L5,LG Electronics Inc,Mono-c-Si,0,320.0,297.3,1.7254999999999998,,,60.0,10.44,40.5,10.01,32.0,0.0026152199999999997,-0.1046115,45.83,1.424238840380844,10.4400046235712,4.666549933425445e-12,0.39531612563435176,892637.099032824,-1.334016366300067,-0.3433,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG320N1K-V5,LG Electronics Inc,Mono-c-Si,0,320.0,294.0,1.65,,,60.0,10.19,40.8,9.62,33.3,0.0037193499999999993,-0.106692,48.5,1.4941904449675545,10.199462592349201,1.3947038818898037e-11,0.30306417263618113,326.36130106756855,6.625216230535809,-0.3535,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1K-Z4,LG Electronics Inc,Mono-c-Si,0,320.0,298.4,1.5876000000000001,1.62,0.98,60.0,9.86,40.9,9.39,34.1,0.0029579999999999997,-0.11452000000000001,43.5,1.5457739106677724,9.860004777054407,3.1825261956323074e-11,0.21698249246134416,447857.49883462244,6.734929391470475,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1T-A5,LG Electronics Inc,Mono-c-Si,0,320.0,294.6,1.706,1.706,1.0,60.0,10.16,40.9,9.45,33.9,0.0020320000000000004,-0.11043,47.3,1.5071399217204209,10.17998068665353,1.613681076328755e-11,0.24451360262739189,124.33297484164471,4.80158726991324,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1T-L5,LG Electronics Inc,Mono-c-Si,1,320.0,295.4,1.7254999999999998,,,60.0,10.3,40.8,9.73,32.9,0.00345874,-0.10999679999999999,46.5,1.4940212294281716,10.308876185386358,1.4086926960624169e-11,0.34516761948952235,400.5354081240494,3.4293527671394513,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1T-V5,LG Electronics Inc,Mono-c-Si,1,320.0,294.6,1.65,,,60.0,10.22,40.4,9.65,33.2,0.0039347,-0.10504,48.5,1.474377157510437,10.229268099223995,1.2701738854190605e-11,0.27449005742509247,302.6821724105832,6.384285443060326,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1W-A5,LG Electronics Inc,Mono-c-Si,0,320.0,296.8,1.648704,1.662,0.992,60.0,10.37,40.7,9.74,32.9,0.003111,-0.10582000000000001,45.9,1.4810542750710554,10.385981332164638,1.185705532377639e-11,0.3361242068227783,218.10497604928068,5.797976872848162,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1W-G4,LG Electronics Inc,Mono-c-Si,0,320.0,298.7,1.5876000000000001,1.62,0.98,60.0,10.05,40.9,9.53,33.6,0.003015,-0.11043,43.2,1.5378112788834504,10.054058535950796,2.8126655041365088e-11,0.27288141753061135,675.7260188172446,9.462126840318797,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320N1W-L5,LG Electronics Inc,Mono-c-Si,0,320.0,296.4,1.7254999999999998,,,60.0,10.52,40.5,10.1,31.7,0.002446952,-0.10465200000000001,46.48,1.4227797578718797,10.520004921125938,4.567161547313185e-12,0.41756703353799157,892659.5195134262,-1.581968249693608,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG320N1W-N5,LG Electronics Inc,Mono-c-Si,0,320.0,298.4,1.7254999999999998,,,60.0,10.53,40.8,10.04,31.9,0.003329586,-0.10501920000000001,44.94,1.4334730055375307,10.530004722510785,4.585518889692002e-12,0.44846829388850695,999995.6385228432,-1.291397362057059,-0.342,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG320N1W-V5,LG Electronics Inc,Mono-c-Si,0,320.0,297.2,1.648704,,,60.0,10.37,40.7,9.74,32.9,0.002741828,-0.1053316,45.95,1.4631760564042806,10.386755870814186,8.470253343263948e-12,0.34012082874074795,210.49655080812585,3.479491646060149,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320S2C-G4,LG Electronics Inc,Mono-c-Si,0,320.0,294.4,1.9012,1.94,0.98,72.0,9.28,45.6,8.66,37.0,0.0027839999999999996,-0.1368,44.1,1.7820880975399647,9.296163304554367,7.007480297994213e-11,0.3741589129048574,214.81960278760076,6.711201329932766,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG320S2W-G4,LG Electronics Inc,Mono-c-Si,0,320.0,294.4,1.9012,1.94,0.98,72.0,9.28,45.6,8.66,37.0,0.0027839999999999996,-0.1368,44.1,1.7820880975399647,9.296163304554367,7.007480297994213e-11,0.3741589129048574,214.81960278760076,6.711201329932766,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325E1C-A5,LG Electronics Inc,Mono-c-Si,0,325.0,301.3,1.65,,,60.0,10.41,40.8,9.77,33.3,0.002082,-0.10608,45.9,1.4839053796188584,10.42605569413344,1.1704642874998809e-11,0.299922633194965,194.4602706876751,5.8000604982601995,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325E1K-A5,LG Electronics Inc,Mono-c-Si,0,325.0,299.5,1.65,,,60.0,10.23,40.9,9.65,33.7,0.003069,-0.10634,47.7,1.4996564026771662,10.239778900976932,1.4438934876022321e-11,0.2659803546817807,278.2499829025773,7.607341490524015,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1C-A5,LG Electronics Inc,Mono-c-Si,0,325.0,301.5,1.648704,1.662,0.992,60.0,10.41,40.8,9.77,33.3,0.003123,-0.10608,45.9,1.4924484197805301,10.425716165356391,1.3703396304213171e-11,0.29800645288281913,197.39211975224632,7.020475111730582,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1C-G4,LG Electronics Inc,Mono-c-Si,0,325.0,303.5,1.5876000000000001,1.62,0.98,60.0,10.08,41.2,9.57,34.0,0.0030239999999999998,-0.11124000000000002,43.2,1.551776922531007,10.083137921620791,2.956788020068835e-11,0.2555935938110735,821.0477563136078,9.873761275231633,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1C-L5,LG Electronics Inc,Mono-c-Si,0,325.0,301.1,1.7254999999999998,,,60.0,10.56,40.6,10.13,32.1,0.0024562560000000004,-0.10491040000000001,46.48,1.4315750788775046,10.56000458098995,5.092249913925212e-12,0.3867080403923599,891447.1714380136,-0.7340304070271881,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG325N1C-N5,LG Electronics Inc,Mono-c-Si,0,325.0,303.2,1.7254999999999998,,,60.0,10.57,40.9,10.07,32.3,0.0033422340000000004,-0.1052766,44.94,1.4422994428851421,10.570004407825204,5.111750639948392e-12,0.41700257901607346,999998.9992077195,-0.4409218645838531,-0.342,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG325N1C-V5,LG Electronics Inc,Mono-c-Si,0,325.0,301.9,1.648704,,,60.0,10.41,40.8,9.77,33.3,0.002752404,-0.10559039999999999,45.95,1.47434627539965,10.426439636655177,9.790517666413182e-12,0.3020716360306647,191.2795161454558,4.67891634972652,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1C-Z4,LG Electronics Inc,Mono-c-Si,0,325.0,302.2,1.5876000000000001,1.62,0.98,60.0,10.08,41.2,9.57,34.0,0.0030239999999999998,-0.11124000000000002,44.8,1.5340652022840902,10.083574572961863,2.1749402612413545e-11,0.2596326245355063,732.1425398208373,7.188302180853573,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1C-Z5,LG Electronics Inc,Mono-c-Si,0,325.0,300.3,1.654016,1.664,0.994,60.0,10.41,40.8,9.77,33.3,0.003123,-0.10608,46.6,1.5029532738186187,10.425303307610266,1.659420714233668e-11,0.2956558968222959,201.1184762724733,8.689505326388252,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1K-A5,LG Electronics Inc,Mono-c-Si,0,325.0,299.4,1.648704,1.662,0.992,60.0,10.23,40.9,9.65,33.7,0.002046,-0.10634,47.7,1.485602380962372,10.240228032985817,1.1150449565045069e-11,0.2691933888492657,269.2451606319143,5.515876831282427,-0.357,N,2025.7.3,6/23/2025,4.0,bootstrapping +LG Electronics Inc LG325N1K-L5,LG Electronics Inc,Mono-c-Si,0,325.0,302.1,1.7254999999999998,,,60.0,10.48,40.6,10.04,32.4,0.00262524,-0.1048698,45.83,1.4329983173815546,10.48000426041052,5.198043663610231e-12,0.36420717470535974,895911.9739816466,-0.4919608764085984,-0.3433,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG325N1K-V5,LG Electronics Inc,Mono-c-Si,0,325.0,298.8,1.648704,,,60.0,10.23,40.9,9.65,33.7,0.0036828,-0.106749,48.5,1.503842059066276,10.239646796986639,1.5579706345438732e-11,0.26502561522923057,281.0479029824646,7.773777186702681,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1T-A5,LG Electronics Inc,Mono-c-Si,0,325.0,299.4,1.706,1.706,1.0,60.0,10.2,41.0,9.48,34.3,0.0020399999999999997,-0.11070000000000002,47.3,1.5186428318641312,10.217669300884145,1.8596106136380173e-11,0.20557544157051255,118.67303207634583,5.981743024977161,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1T-L5,LG Electronics Inc,Mono-c-Si,1,325.0,300.2,1.7254999999999998,,,60.0,10.34,40.9,9.79,33.2,0.003472172,-0.1102664,46.5,1.5011264103262572,10.346421993814976,1.5085305676200318e-11,0.3186677061132449,513.0843112819563,3.9649441258493665,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1T-V5,LG Electronics Inc,Mono-c-Si,1,325.0,299.3,1.65,,,60.0,10.26,40.5,9.7,33.5,0.0039501,-0.1053,48.5,1.4819761092465602,10.267803710082186,1.3728898232650783e-11,0.24831046507875695,326.4685062287183,7.020867639818324,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1W-A5,LG Electronics Inc,Mono-c-Si,0,325.0,301.5,1.648704,1.662,0.992,60.0,10.41,40.8,9.77,33.3,0.003123,-0.10608,45.9,1.4924484197805301,10.425716165356391,1.3703396304213171e-11,0.29800645288281913,197.39211975224632,7.020475111730582,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1W-G4,LG Electronics Inc,Mono-c-Si,0,325.0,303.5,1.5876000000000001,1.62,0.98,60.0,10.08,41.2,9.57,34.0,0.0030239999999999998,-0.11124000000000002,43.2,1.551776922531007,10.083137921620791,2.956788020068835e-11,0.2555935938110735,821.0477563136078,9.873761275231633,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325N1W-L5,LG Electronics Inc,Mono-c-Si,0,325.0,301.1,1.7254999999999998,,,60.0,10.56,40.6,10.13,32.1,0.0024562560000000004,-0.10491040000000001,46.48,1.4315750788775046,10.56000458098995,5.092249913925212e-12,0.3867080403923599,891447.1714380136,-0.7340304070271881,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG325N1W-N5,LG Electronics Inc,Mono-c-Si,0,325.0,303.2,1.7254999999999998,,,60.0,10.57,40.9,10.07,32.3,0.0033422340000000004,-0.1052766,44.94,1.4422994428851421,10.570004407825204,5.111750639948392e-12,0.41700257901607346,999998.9992077195,-0.4409218645838531,-0.342,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG325N1W-V5,LG Electronics Inc,Mono-c-Si,0,325.0,301.9,1.648704,,,60.0,10.41,40.8,9.77,33.3,0.002752404,-0.10559039999999999,45.95,1.47434627539965,10.426439636655177,9.790517666413182e-12,0.3020716360306647,191.2795161454558,4.67891634972652,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325S2C-G4,LG Electronics Inc,Mono-c-Si,0,325.0,299.1,1.9012,1.94,0.98,72.0,9.35,45.8,8.75,37.2,0.0028049999999999998,-0.1374,44.1,1.7883299334061127,9.363640431333737,6.925461325138694e-11,0.3680407385059414,252.27801988387094,6.534861538825944,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG325S2W-G4,LG Electronics Inc,Mono-c-Si,0,325.0,299.1,1.9012,1.94,0.98,72.0,9.35,45.8,8.75,37.2,0.0028049999999999998,-0.1374,44.1,1.7883299334061127,9.363640431333737,6.925461325138694e-11,0.3680407385059414,252.27801988387094,6.534861538825944,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330E1C-A5,LG Electronics Inc,Mono-c-Si,0,330.0,306.0,1.65,,,60.0,10.45,40.9,9.8,33.7,0.00209,-0.10634,45.9,1.4951895826486583,10.46533262409226,1.3498504446247304e-11,0.2621118658668638,178.643200185111,7.001962479025441,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1C-A5,LG Electronics Inc,Mono-c-Si,0,330.0,306.3,1.648704,1.662,0.992,60.0,10.45,40.9,9.8,33.7,0.0031349999999999998,-0.10634,45.9,1.503847609495288,10.465015344149494,1.5805098581631045e-11,0.2601615344252636,181.06065517133092,8.237962662241854,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1C-L5,LG Electronics Inc,Mono-c-Si,0,330.0,305.9,1.7254999999999998,,,60.0,10.6,40.7,10.16,32.5,0.00246556,-0.10516880000000002,46.48,1.4403643826352646,10.600004217767873,5.66967908339602e-12,0.3559927301317589,894688.167164127,0.10879729057410038,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG330N1C-N5,LG Electronics Inc,Mono-c-Si,0,330.0,307.9,1.7254999999999998,,,60.0,10.61,41.0,10.1,32.7,0.0033548820000000004,-0.10553400000000002,44.94,1.4515452659545667,10.610483041661537,5.73533601806514e-12,0.38527870738815895,8462.640334203381,0.4705819189805837,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1C-V5,LG Electronics Inc,Mono-c-Si,0,330.0,306.7,1.648704,,,60.0,10.45,40.9,9.8,33.7,0.00276298,-0.10584919999999998,45.95,1.4855254933867996,10.465690800008968,1.129461772893044e-11,0.2642938541813688,176.01848123657865,5.874060528024488,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1C-Z4,LG Electronics Inc,Mono-c-Si,0,330.0,307.0,1.5876000000000001,1.62,0.98,60.0,10.11,41.5,9.63,34.3,0.0030329999999999997,-0.11205000000000001,44.8,1.5440254561416462,10.11103541211567,2.1438774452634687e-11,0.25463346500555345,2486.299432467091,7.023866521942696,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1C-Z5,LG Electronics Inc,Mono-c-Si,0,330.0,305.1,1.654016,1.664,0.994,60.0,10.45,40.9,9.8,33.7,0.0031349999999999998,-0.10634,46.6,1.514472549498277,10.464630619251912,1.9133943348789837e-11,0.2577738475648587,184.11637969795044,9.92183508732032,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1K-A5,LG Electronics Inc,Mono-c-Si,0,330.0,304.2,1.648704,1.662,0.992,60.0,10.27,41.0,9.69,34.1,0.002054,-0.10660000000000001,47.7,1.4960143282462461,10.279139872809594,1.2673451068422734e-11,0.23118402461763965,259.76942854062537,6.58370323348793,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1K-L5,LG Electronics Inc,Mono-c-Si,0,330.0,306.9,1.7254999999999998,,,60.0,10.52,40.7,10.07,32.8,0.00263526,-0.1051281,45.83,1.441750566965737,10.520003505867495,5.7818562623743275e-12,0.33324839897427,999990.2077395959,0.3448221303674264,-0.3433,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG330N1K-V5,LG Electronics Inc,Mono-c-Si,0,330.0,303.6,1.648704,,,60.0,10.27,41.0,9.69,34.1,0.0036972,-0.10701000000000001,48.5,1.5144692302609215,10.278616490841575,1.7708422153784582e-11,0.22695549080124489,270.50837176959044,8.865708899643503,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1T-A5,LG Electronics Inc,Mono-c-Si,0,330.0,304.1,1.706,1.706,1.0,60.0,10.24,41.1,9.52,34.7,0.0020480000000000003,-0.11097000000000001,47.3,1.5293328534098902,10.25450989499233,2.1108938129316912e-11,0.1670974203568582,117.9248767049495,7.038919830138734,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1T-L5,LG Electronics Inc,Mono-c-Si,1,330.0,304.9,1.7254999999999998,,,60.0,10.38,41.0,9.85,33.5,0.003485604,-0.11053600000000001,46.5,1.5081955793402562,10.384274114496563,1.6134137687995878e-11,0.29252922420336036,710.428656932573,4.492457450529016,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1T-V5,LG Electronics Inc,Mono-c-Si,1,330.0,304.1,1.65,,,60.0,10.3,40.6,9.77,33.8,0.0039655,-0.10556000000000001,48.5,1.4881006995044381,10.305004972461427,1.4467615858715548e-11,0.22258422547398726,458.06796428132765,7.430509008495031,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1W-A5,LG Electronics Inc,Mono-c-Si,0,330.0,306.3,1.648704,1.662,0.992,60.0,10.45,40.9,9.8,33.7,0.0031349999999999998,-0.10634,45.9,1.503847609495288,10.465015344149494,1.5805098581631045e-11,0.2601615344252636,181.06065517133092,8.237962662241854,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1W-L5,LG Electronics Inc,Mono-c-Si,0,330.0,305.9,1.7254999999999998,,,60.0,10.6,40.7,10.16,32.5,0.00246556,-0.10516880000000002,46.48,1.4403643826352646,10.600004217767873,5.66967908339602e-12,0.3559927301317589,894688.167164127,0.10879729057410038,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG330N1W-N5,LG Electronics Inc,Mono-c-Si,0,330.0,307.9,1.7254999999999998,,,60.0,10.61,41.0,10.1,32.7,0.0033548820000000004,-0.10553400000000002,44.94,1.4515452659545667,10.610483041661537,5.73533601806514e-12,0.38527870738815895,8462.640334203381,0.4705819189805837,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330N1W-V5,LG Electronics Inc,Mono-c-Si,0,330.0,306.7,1.648704,,,60.0,10.45,40.9,9.8,33.7,0.00276298,-0.10584919999999998,45.95,1.4855254933867996,10.465690800008968,1.129461772893044e-11,0.2642938541813688,176.01848123657865,5.874060528024488,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330Q1K-A5,LG Electronics Inc,Mono-c-Si,0,330.0,306.5,1.6732799999999999,1.68,0.996,60.0,10.73,42.5,9.45,35.2,0.004292000000000001,-0.102,48.7,1.5414212658352267,10.798364990982144,1.0324778557749188e-11,0.25407694454643387,39.87780262703805,13.245058242870533,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330S2C-G4,LG Electronics Inc,Mono-c-Si,0,330.0,303.9,1.9012,1.94,0.98,72.0,9.41,46.0,8.85,37.3,0.002823,-0.138,44.1,1.7900517779437517,9.41938555251043,6.427426557870313e-11,0.37565910902488936,376.6376419723292,5.822599171839255,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG330S2W-G4,LG Electronics Inc,Mono-c-Si,0,330.0,303.9,1.9012,1.94,0.98,72.0,9.41,46.0,8.85,37.3,0.002823,-0.138,44.1,1.7900517779437517,9.41938555251043,6.427426557870313e-11,0.37565910902488936,376.6376419723292,5.822599171839255,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG333N1C-A5,LG Electronics Inc,Mono-c-Si,0,333.0,309.2,1.648704,1.662,0.992,60.0,10.47,41.0,9.81,34.0,0.003141,-0.10660000000000001,45.9,1.51308914840751,10.48457239425037,1.7471694337226476e-11,0.23472638189159667,168.64663339595924,9.109265666997103,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG333N1C-V5,LG Electronics Inc,Mono-c-Si,0,333.0,309.6,1.648704,,,60.0,10.47,40.9,9.83,33.9,0.0027682680000000004,-0.10584919999999998,45.95,1.4891173302961234,10.483723385793652,1.2102525498130321e-11,0.24045259073036343,183.44879846861244,6.449267139871325,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG333N1W-A5,LG Electronics Inc,Mono-c-Si,0,333.0,309.2,1.648704,1.662,0.992,60.0,10.47,41.0,9.81,34.0,0.003141,-0.10660000000000001,45.9,1.51308914840751,10.48457239425037,1.7471694337226476e-11,0.23472638189159667,168.64663339595924,9.109265666997103,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG333N1W-V5,LG Electronics Inc,Mono-c-Si,0,333.0,309.6,1.648704,,,60.0,10.47,40.9,9.83,33.9,0.0027682680000000004,-0.10584919999999998,45.95,1.4891173302961234,10.483723385793652,1.2102525498130321e-11,0.24045259073036343,183.44879846861244,6.449267139871325,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335E1C-A5,LG Electronics Inc,Mono-c-Si,0,335.0,310.8,1.65,,,60.0,10.49,41.0,9.83,34.1,0.002098,-0.10660000000000001,45.9,1.5064876105740381,10.50420642757218,1.5538998301337304e-11,0.22456683273033176,165.81973702150782,8.200264237110597,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1C-A5,LG Electronics Inc,Mono-c-Si,0,335.0,311.1,1.648704,1.662,0.992,60.0,10.49,41.0,9.83,34.1,0.003147,-0.10660000000000001,45.9,1.5152512278859884,10.503910364097901,1.8192703929230764e-11,0.22258467482119773,167.85421529194204,9.45037032369471,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1C-L5,LG Electronics Inc,Mono-c-Si,0,335.0,310.7,1.7254999999999998,,,60.0,10.64,40.8,10.19,32.9,0.0024748640000000002,-0.1054272,46.48,1.4491468740918236,10.640003462631359,6.303733020661897e-12,0.3254231889300904,999980.8885310253,0.9464271333104962,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG335N1C-N5,LG Electronics Inc,Mono-c-Si,0,335.0,312.7,1.7254999999999998,,,60.0,10.65,41.1,10.13,33.1,0.0033675300000000005,-0.10579140000000002,44.94,1.4621794631651994,10.652251186902285,6.59113150390988e-12,0.3485532536532552,1648.9489546370862,1.5929342051423954,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1C-V5,LG Electronics Inc,Mono-c-Si,0,335.0,311.5,1.648704,,,60.0,10.49,41.0,9.83,34.1,0.0027735560000000004,-0.106108,45.95,1.4967108580780273,10.504540740484227,1.3004331894468312e-11,0.22678321953195232,163.6062471320087,7.0644944537263274,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1C-Z5,LG Electronics Inc,Mono-c-Si,0,335.0,309.8,1.654016,1.664,0.994,60.0,10.49,41.0,9.83,34.1,0.003147,-0.10660000000000001,46.6,1.5259962265665943,10.503551992442773,2.2018183783123483e-11,0.22016019795776717,170.4163059424902,11.148987573238623,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1K-A5,LG Electronics Inc,Mono-c-Si,0,335.0,308.9,1.648704,1.662,0.992,60.0,10.31,41.1,9.72,34.5,0.0020620000000000005,-0.10686000000000001,47.7,1.507163249040153,10.318545632839445,1.4555571303434394e-11,0.19341371889128972,233.34672685723226,7.757040509238878,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1K-L5,LG Electronics Inc,Mono-c-Si,0,335.0,311.6,1.7254999999999998,,,60.0,10.56,40.8,10.1,33.2,0.0026452800000000003,-0.10538639999999998,45.83,1.4504960327390337,10.560003193801636,6.422338187478569e-12,0.30243797490972874,999998.4540035698,1.1764380326847124,-0.3433,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG335N1K-V5,LG Electronics Inc,Mono-c-Si,0,335.0,308.3,1.648704,,,60.0,10.31,41.1,9.72,34.5,0.0037116000000000002,-0.10727100000000002,48.5,1.5258337166778015,10.318064392289033,2.0332316380371436e-11,0.18911958745523014,241.78175980184898,10.062426166134344,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1T-A5,LG Electronics Inc,Mono-c-Si,0,335.0,308.9,1.706,1.706,1.0,60.0,10.28,41.2,9.55,35.1,0.002056,-0.11124000000000002,47.3,1.5408444347735064,10.291689728197593,2.4234523101589043e-11,0.12875886684878868,113.2311318592037,8.209485791038954,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1T-L5,LG Electronics Inc,Mono-c-Si,1,335.0,309.7,1.7254999999999998,,,60.0,10.42,41.1,9.91,33.8,0.003499036,-0.11080560000000002,46.5,1.5152296825306295,10.422425057075428,1.723485357070547e-11,0.2667443124531561,1146.1486299912497,5.012080728880016,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1T-V5,LG Electronics Inc,Mono-c-Si,1,335.0,308.8,1.65,,,60.0,10.34,40.7,9.83,34.1,0.0039809,-0.10582000000000001,48.5,1.4949106989354461,10.343329969592956,1.5412953651955082e-11,0.19715929021061426,612.2059163738013,7.941515483437448,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1W-A5,LG Electronics Inc,Mono-c-Si,0,335.0,311.1,1.648704,1.662,0.992,60.0,10.49,41.0,9.83,34.1,0.003147,-0.10660000000000001,45.9,1.5152512278859884,10.503910364097901,1.8192703929230764e-11,0.22258467482119773,167.85421529194204,9.45037032369471,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1W-L5,LG Electronics Inc,Mono-c-Si,0,335.0,310.7,1.7254999999999998,,,60.0,10.64,40.8,10.19,32.9,0.0024748640000000002,-0.1054272,46.48,1.4491468740918236,10.640003462631359,6.303733020661897e-12,0.3254231889300904,999980.8885310253,0.9464271333104962,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG335N1W-N5,LG Electronics Inc,Mono-c-Si,0,335.0,312.7,1.7254999999999998,,,60.0,10.65,41.1,10.13,33.1,0.0033675300000000005,-0.10579140000000002,44.94,1.4621794631651994,10.652251186902285,6.59113150390988e-12,0.3485532536532552,1648.9489546370862,1.5929342051423954,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335N1W-V5,LG Electronics Inc,Mono-c-Si,0,335.0,311.5,1.648704,,,60.0,10.49,41.0,9.83,34.1,0.0027735560000000004,-0.106108,45.95,1.4967108580780273,10.504540740484227,1.3004331894468312e-11,0.22678321953195232,163.6062471320087,7.0644944537263274,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335Q1C-V5,LG Electronics Inc,Mono-c-Si,0,335.0,315.2,1.6732799999999999,,,60.0,10.74,42.6,9.47,35.4,0.0030802320000000005,-0.10351800000000001,44.53,1.5344260581180402,10.804698498250747,8.545850656816535e-12,0.24327373789625473,40.38362071660555,10.289597735506392,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335Q1K-A5,LG Electronics Inc,Mono-c-Si,0,335.0,311.2,1.6732799999999999,1.68,0.996,60.0,10.74,42.6,9.53,35.4,0.004296,-0.10224000000000001,48.7,1.4935139033976255,10.802891544798603,4.021583935778763e-12,0.25271562640311673,43.156291313175466,4.822291269010459,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335S2C-G4,LG Electronics Inc,Mono-c-Si,0,335.0,308.6,1.9012,1.94,0.98,72.0,9.48,46.2,8.94,37.5,0.002844,-0.1386,44.1,1.7963937822330136,9.48694358326653,6.362767196982351e-11,0.3696122400964589,504.62765113220433,5.66294511848189,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG335S2W-G4,LG Electronics Inc,Mono-c-Si,0,335.0,308.6,1.9012,1.94,0.98,72.0,9.48,46.2,8.94,37.5,0.002844,-0.1386,44.1,1.7963937822330136,9.48694358326653,6.362767196982351e-11,0.3696122400964589,504.62765113220433,5.66294511848189,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340M1K-L5,LG Electronics Inc,Mono-c-Si,0,340.0,316.4,1.7255,,,60.0,10.6,40.9,10.12,33.6,0.0026552999999999998,-0.10564469999999998,45.83,1.458646607171949,10.600006423651493,7.044000894721556e-12,0.27497119217789423,453747.3769596631,1.9091361927566957,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1C-A5,LG Electronics Inc,Mono-c-Si,0,340.0,315.8,1.648704,1.662,0.992,60.0,10.53,41.1,9.86,34.5,0.0031589999999999995,-0.10686000000000001,45.9,1.5266586892834222,10.542429734759882,2.089978484372537e-11,0.1852713398430973,156.9548550090548,10.657633947724326,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1C-L5,LG Electronics Inc,Mono-c-Si,0,340.0,315.4,1.7254999999999998,,,60.0,10.68,40.9,10.22,33.3,0.002484168,-0.1056856,46.48,1.4579230199088844,10.680003150635455,6.99911021310874e-12,0.29499760948673276,999997.7116538475,1.7789673192180542,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG340N1C-N5,LG Electronics Inc,Mono-c-Si,0,340.0,317.5,1.7254999999999998,,,60.0,10.69,41.2,10.16,33.5,0.003380178,-0.10604880000000001,44.94,1.4731102644668526,10.693824455077973,7.600583774607128e-12,0.31203156193281684,872.1811027256775,2.7559116316104566,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1C-V5,LG Electronics Inc,Mono-c-Si,0,340.0,316.3,1.648704,,,60.0,10.53,41.1,9.86,34.5,0.002784132,-0.1063668,45.95,1.5079039769978755,10.543017709613345,1.4944624094941392e-11,0.18953470935929162,153.31425843316208,8.25049873300334,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1C-Z5,LG Electronics Inc,Mono-c-Si,0,340.0,314.6,1.654016,1.664,0.994,60.0,10.53,41.1,9.86,34.5,0.0031589999999999995,-0.10686000000000001,46.6,1.5375236945465576,10.542096061717194,2.5287220201259775e-11,0.18281038169555228,159.14215505098454,12.370930740202834,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1K-L5,LG Electronics Inc,Mono-c-Si,0,340.0,316.4,1.7254999999999998,,,60.0,10.6,40.9,10.12,33.6,0.0026552999999999998,-0.10564469999999998,45.83,1.458646607171949,10.600006423651493,7.044000894721556e-12,0.27497119217789423,453747.3769596631,1.9091361927566957,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1K-V5,LG Electronics Inc,Mono-c-Si,0,340.0,313.0,1.648704,,,60.0,10.35,41.2,9.75,34.9,0.0037259999999999997,-0.10753200000000002,48.5,1.5371977192901785,10.357145408375326,2.329859391148667e-11,0.15155052534669539,219.5183065853999,11.253409266869072,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1T-L5,LG Electronics Inc,Mono-c-Si,1,340.0,314.4,1.7254999999999998,,,60.0,10.46,41.2,9.97,34.1,0.0035124680000000004,-0.11107520000000001,46.5,1.522229612820043,10.46086734713328,1.838888045121744e-11,0.24130535352590363,2910.085375832033,5.524011589896155,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1T-V5,LG Electronics Inc,Mono-c-Si,1,340.0,313.6,1.65,,,60.0,10.38,40.8,9.89,34.4,0.0039963,-0.10608,48.5,1.5016874097693176,10.38194838542359,1.6401250843867896e-11,0.17207627920293356,916.7343331952658,8.444713621438389,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1W-A5,LG Electronics Inc,Mono-c-Si,0,340.0,315.8,1.648704,1.662,0.992,60.0,10.53,41.1,9.86,34.5,0.0031589999999999995,-0.10686000000000001,45.9,1.5266586892834222,10.542429734759882,2.089978484372537e-11,0.1852713398430973,156.9548550090548,10.657633947724326,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1W-L5,LG Electronics Inc,Mono-c-Si,0,340.0,315.4,1.7254999999999998,,,60.0,10.68,40.9,10.22,33.3,0.002484168,-0.1056856,46.48,1.4579230199088844,10.680003150635455,6.99911021310874e-12,0.29499760948673276,999997.7116538475,1.7789673192180542,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG340N1W-N5,LG Electronics Inc,Mono-c-Si,0,340.0,317.5,1.7254999999999998,,,60.0,10.69,41.2,10.16,33.5,0.003380178,-0.10604880000000001,44.94,1.4731102644668526,10.693824455077973,7.600583774607128e-12,0.31203156193281684,872.1811027256775,2.7559116316104566,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340N1W-V5,LG Electronics Inc,Mono-c-Si,0,340.0,316.3,1.648704,,,60.0,10.53,41.1,9.86,34.5,0.002784132,-0.1063668,45.95,1.5079039769978755,10.543017709613345,1.4944624094941392e-11,0.18953470935929162,153.31425843316208,8.25049873300334,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340Q1C-A5,LG Electronics Inc,Mono-c-Si,0,340.0,318.4,1.6732799999999999,1.68,0.996,60.0,10.75,42.6,9.57,35.6,0.003225,-0.10224000000000001,45.7,1.545495192026385,10.800921616532905,1.0554025685405186e-11,0.2166924433284104,45.74567592962637,13.53364390294744,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340Q1C-V5,LG Electronics Inc,Mono-c-Si,0,340.0,320.0,1.6732799999999999,,,60.0,10.75,42.6,9.56,35.6,0.0030831,-0.10351800000000001,44.53,1.531930035781841,10.80266453061451,8.255226390910605e-12,0.2200065034757582,44.90821215275759,9.937334691896398,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340Q1K-A5,LG Electronics Inc,Mono-c-Si,0,340.0,316.0,1.6732799999999999,1.68,0.996,60.0,10.75,42.6,9.6,35.7,0.0043,-0.10224000000000001,48.7,1.5431269550026097,10.79632288770181,1.0151757199650996e-11,0.20565089915422943,47.72472676790759,13.01934438008479,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340S2C-G4,LG Electronics Inc,Mono-c-Si,0,340.0,313.3,1.9012,1.94,0.98,72.0,9.54,46.4,9.02,37.7,0.002862,-0.1392,44.1,1.802818843880984,9.544620710123784,6.299389464662936e-11,0.3640545669475954,751.6335697818499,5.514077874347457,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340S2W-A5,LG Electronics Inc,Mono-c-Si,0,340.0,307.9,2.012016,2.004,1.004,72.0,9.91,45.9,9.35,36.4,0.002973,-0.1377,47.6,1.7622885427706845,9.916199467136101,4.809472657185528e-11,0.4581603741980735,732.3806447931667,2.933776002527039,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG340S2W-G4,LG Electronics Inc,Mono-c-Si,0,340.0,313.3,1.9012,1.94,0.98,72.0,9.54,46.4,9.02,37.7,0.002862,-0.1392,44.1,1.802818843880984,9.544620710123784,6.299389464662936e-11,0.3640545669475954,751.6335697818499,5.514077874347457,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345M1K-L5,LG Electronics Inc,Mono-c-Si,0,345.0,321.2,1.7255,,,60.0,10.64,41.0,10.15,34.0,0.00266532,-0.105903,45.83,1.4695147011580862,10.641382393987032,8.111682910115474e-12,0.23875940211960764,1837.6816766775098,3.061997060075408,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1C-A5,LG Electronics Inc,Mono-c-Si,0,345.0,320.6,1.648704,1.662,0.992,60.0,10.57,41.2,9.89,34.9,0.0031709999999999998,-0.10712,45.9,1.5380694455959971,10.580599321018733,2.3963179512804543e-11,0.1482172130553387,147.80719806313047,11.859696200245132,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1C-L5,LG Electronics Inc,Mono-c-Si,0,345.0,320.2,1.7254999999999998,,,60.0,10.72,41.0,10.24,33.7,0.002493472,-0.10594400000000001,46.48,1.4661061277204541,10.720002874828568,7.674440177843906e-12,0.2681698501335062,999999.7501258024,2.5131872562588415,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG345N1C-N5,LG Electronics Inc,Mono-c-Si,0,345.0,322.3,1.7254999999999998,,,60.0,10.72,41.3,10.19,33.9,0.0033896640000000006,-0.1063062,44.94,1.4834148290362132,10.724012210153566,8.64605972329936e-12,0.2760180520212005,737.4772118770421,3.8191246258016975,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1C-V5,LG Electronics Inc,Mono-c-Si,0,345.0,321.0,1.648704,,,60.0,10.57,41.2,9.89,34.9,0.0027947080000000003,-0.1066256,45.95,1.5191035495324954,10.581147429170608,1.7142280587425804e-11,0.1525441842750995,144.6425007773333,9.431892048726008,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1C-Z5,LG Electronics Inc,Mono-c-Si,0,345.0,319.3,1.654016,1.664,0.994,60.0,10.57,41.2,9.89,34.9,0.0031709999999999998,-0.10712,46.6,1.5490544069725496,10.580288806870913,2.8985244950584973e-11,0.14572008122250305,149.70261228877993,13.587597151339676,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1K-A6,LG Electronics Inc,Mono-c-Si,0,345.0,319.2,1.81308,,,60.0,10.76,41.4,10.32,33.5,0.00315268,-0.1075986,47.15,1.4791218694212682,10.760003666767538,7.517793458006345e-12,0.30730628334925547,901794.7352991201,1.6348373062955976,-0.3442,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG345N1K-B6,LG Electronics Inc,Mono-c-Si,0,345.0,318.6,1.81,,,60.0,10.64,41.3,10.09,34.2,0.0029685600000000003,-0.10622359999999999,48.0,1.4787969294834076,10.646402540060132,7.83524430262257e-12,0.24679895527405027,410.14048680080543,3.201277520004606,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1K-L5,LG Electronics Inc,Mono-c-Si,0,345.0,321.2,1.7254999999999998,,,60.0,10.64,41.0,10.15,34.0,0.00266532,-0.105903,45.83,1.4695147011580862,10.641382393987032,8.111682910115474e-12,0.23875940211960764,1837.6816766775098,3.061997060075408,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1T-L5,LG Electronics Inc,Mono-c-Si,1,345.0,319.2,1.7254999999999998,,,60.0,10.5,41.3,10.03,34.4,0.0035258999999999998,-0.1113448,46.5,1.529989727807165,10.500003354198109,1.986075339430058e-11,0.21604562452023093,676324.0323219957,6.145422775029741,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1W-A5,LG Electronics Inc,Mono-c-Si,0,345.0,320.6,1.648704,1.662,0.992,60.0,10.57,41.2,9.89,34.9,0.0031709999999999998,-0.10712,45.9,1.5380694455959971,10.580599321018733,2.3963179512804543e-11,0.1482172130553387,147.80719806313047,11.859696200245132,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1W-L5,LG Electronics Inc,Mono-c-Si,0,345.0,320.2,1.7254999999999998,,,60.0,10.72,41.0,10.24,33.7,0.002493472,-0.10594400000000001,46.48,1.4661061277204541,10.720002874828568,7.674440177843906e-12,0.2681698501335062,999999.7501258024,2.5131872562588415,-0.3467,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG345N1W-N5,LG Electronics Inc,Mono-c-Si,0,345.0,322.3,1.7254999999999998,,,60.0,10.72,41.3,10.19,33.9,0.0033896640000000006,-0.1063062,44.94,1.4834148290362132,10.724012210153566,8.64605972329936e-12,0.2760180520212005,737.4772118770421,3.8191246258016975,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345N1W-V5,LG Electronics Inc,Mono-c-Si,0,345.0,321.0,1.648704,,,60.0,10.57,41.2,9.89,34.9,0.0027947080000000003,-0.1066256,45.95,1.5191035495324954,10.581147429170608,1.7142280587425804e-11,0.1525441842750995,144.6425007773333,9.431892048726008,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345Q1C-A5,LG Electronics Inc,Mono-c-Si,0,345.0,323.2,1.6732799999999999,1.68,0.996,60.0,10.76,42.6,9.64,35.8,0.003228,-0.10224000000000001,45.7,1.544771891172707,10.801674283813261,1.050261522742322e-11,0.19354172884210433,49.971080802690146,13.454225021164595,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345Q1C-V5,LG Electronics Inc,Mono-c-Si,0,345.0,324.8,1.6732799999999999,,,60.0,10.76,42.6,9.64,35.8,0.003085968,-0.10351800000000001,44.53,1.5303636346019713,10.802631537547121,8.098278613098408e-12,0.19698823477495414,49.7189059870198,9.727497655704731,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345Q1K-A5,LG Electronics Inc,Mono-c-Si,0,345.0,320.8,1.6732799999999999,1.68,0.996,60.0,10.76,42.6,9.68,35.9,0.0043040000000000005,-0.10224000000000001,48.7,1.541603249981612,10.797016661034492,9.970021074255438e-12,0.1828348275168861,53.14641141729382,12.814935602371714,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345Q1K-V5,LG Electronics Inc,Mono-c-Si,0,345.0,320.7,1.6732799999999999,,,60.0,10.34,42.7,9.61,36.0,0.00327778,-0.10363290000000001,49.01,1.500291340445427,10.358364470541778,4.349820675127506e-12,0.19870216872094124,111.87801038568735,4.5647885732648055,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345S2C-G4,LG Electronics Inc,Mono-c-Si,0,345.0,318.0,1.9012,1.94,0.98,72.0,9.61,46.6,9.11,37.9,0.0028829999999999997,-0.1398,44.1,1.8092156157884038,9.612314718159485,6.241356298197946e-11,0.35821420614875676,1487.1957678498525,5.363175067702005,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345S2W-A5,LG Electronics Inc,Mono-c-Si,0,345.0,312.6,2.012016,2.004,1.004,72.0,9.96,46.1,9.41,36.7,0.002988,-0.1383,47.6,1.7724550057044084,9.96476793411225,5.019470286802968e-11,0.4401383233363043,919.4292701191742,3.2424026681393263,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG345S2W-G4,LG Electronics Inc,Mono-c-Si,0,345.0,318.0,1.9012,1.94,0.98,72.0,9.61,46.6,9.11,37.9,0.0028829999999999997,-0.1398,44.1,1.8092156157884038,9.612314718159485,6.241356298197946e-11,0.35821420614875676,1487.1957678498525,5.363175067702005,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350M1K-L5,LG Electronics Inc,Mono-c-Si,0,350.0,326.0,1.7255,,,60.0,10.68,41.1,10.18,34.4,0.00267534,-0.1061613,45.83,1.536551481392069,10.680004325285546,1.7605176773886934e-11,0.2511882625056033,620246.2862961997,-99.99994075718261,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1C-L5,LG Electronics Inc,Mono-c-Si,0,350.0,325.0,1.7254999999999998,,,60.0,10.76,41.1,10.27,34.1,0.002502776,-0.10620240000000002,46.48,1.4748272667516549,10.760005365867658,8.492460378575946e-12,0.23438710577448554,470012.21352182596,3.329159237628821,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1C-N5,LG Electronics Inc,Mono-c-Si,0,350.0,327.1,1.7254999999999998,,,60.0,10.76,41.4,10.22,34.3,0.0034023120000000002,-0.10656360000000001,44.94,1.49434227058074,10.764777779295061,9.93102353715969e-12,0.24000395248964201,540.5110605033377,4.970915420887096,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1C-V5,LG Electronics Inc,Mono-c-Si,0,350.0,325.8,1.648704,,,60.0,10.61,41.3,9.92,35.3,0.0028052840000000003,-0.10688439999999999,45.95,1.5303090452536972,10.618953267178863,1.9626871970045423e-11,0.11580753682574557,137.23682367714247,10.608617199301447,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1K-A6,LG Electronics Inc,Mono-c-Si,0,350.0,323.9,1.81308,,,60.0,10.8,41.5,10.35,33.9,0.0031644000000000004,-0.10785850000000002,47.15,1.4879762845799644,10.80000299592765,8.333922470854888e-12,0.2773937094099129,999992.8225783873,2.459972404673287,-0.3442,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG350N1K-B6,LG Electronics Inc,Mono-c-Si,0,350.0,323.4,1.81,,,60.0,10.68,41.4,10.12,34.6,0.0029797200000000004,-0.10648079999999999,48.0,1.4896085655904747,10.686524739221872,8.990477237506101e-12,0.21058690046660633,344.6985430826597,4.337336527566596,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1K-E6,LG Electronics Inc,Mono-c-Si,0,350.0,325.0,1.79,,,60.0,10.83,40.6,10.35,33.9,0.00278331,-0.10478860000000001,47.2,1.4365884595189837,10.83000495470418,5.765744494430778e-12,0.21154893006396466,462314.45785851177,0.15341127038838057,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1K-L5,LG Electronics Inc,Mono-c-Si,0,350.0,326.0,1.7254999999999998,,,60.0,10.68,41.1,10.18,34.4,0.00267534,-0.1061613,45.83,1.536551481392069,10.680004325285546,1.7605176773886934e-11,0.2511882625056033,620246.2862961997,-99.99994075718261,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1W-L5,LG Electronics Inc,Mono-c-Si,0,350.0,325.0,1.7254999999999998,,,60.0,10.76,41.1,10.27,34.1,0.002502776,-0.10620240000000002,46.48,1.4748272667516549,10.760005365867658,8.492460378575946e-12,0.23438710577448554,470012.21352182596,3.329159237628821,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1W-N5,LG Electronics Inc,Mono-c-Si,0,350.0,327.1,1.7254999999999998,,,60.0,10.76,41.4,10.22,34.3,0.0034023120000000002,-0.10656360000000001,44.94,1.49434227058074,10.764777779295061,9.93102353715969e-12,0.24000395248964201,540.5110605033377,4.970915420887096,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N1W-V5,LG Electronics Inc,Mono-c-Si,0,350.0,325.8,1.648704,,,60.0,10.61,41.3,9.92,35.3,0.0028052840000000003,-0.10688439999999999,45.95,1.5303090452536972,10.618953267178863,1.9626871970045423e-11,0.11580753682574557,137.23682367714247,10.608617199301447,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N2C-B3,LG Electronics Inc,Mono-c-Si,0,350.0,319.5,1.9012,1.94,0.98,72.0,9.74,48.1,9.24,37.9,0.001948,-0.13468000000000002,47.5,1.7748740489017234,9.74049758168017,1.654898684396861e-11,0.5324813762289142,10423.156325176702,1.4836741434061096,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N2T-A4,LG Electronics Inc,Mono-c-Si,1,350.0,321.7,1.9502,1.99,0.98,72.0,9.62,47.6,9.03,38.8,0.0028859999999999997,-0.12852000000000002,46.8,1.7708506936161952,9.633573796295117,2.0040991188069154e-11,0.3751452622761261,265.8723746226513,6.930754075852981,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350N2W-B3,LG Electronics Inc,Mono-c-Si,0,350.0,319.5,1.9012,1.94,0.98,72.0,9.74,48.1,9.24,37.9,0.001948,-0.13468000000000002,47.5,1.7748740489017234,9.74049758168017,1.654898684396861e-11,0.5324813762289142,10423.156325176702,1.4836741434061096,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350Q1C-A5,LG Electronics Inc,Mono-c-Si,0,350.0,328.0,1.6732799999999999,1.68,0.996,60.0,10.77,42.7,9.71,36.0,0.003231,-0.10248,45.7,1.5458308087472743,10.805394227899018,1.0114612547894308e-11,0.18113126850085562,55.11587281213341,13.071886651386247,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350Q1C-V5,LG Electronics Inc,Mono-c-Si,0,350.0,329.7,1.6732799999999999,,,60.0,10.77,42.7,9.7,36.1,0.003088836,-0.103761,44.53,1.5344289220785063,10.804467517228112,8.222832407535089e-12,0.17255412567872297,53.91766172901362,9.834680430059171,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350Q1K-A5,LG Electronics Inc,Mono-c-Si,0,350.0,325.5,1.6732799999999999,1.68,0.996,60.0,10.77,42.7,9.75,36.2,0.004308,-0.10248,48.7,1.5448923870442186,10.799017906779017,9.989726812000169e-12,0.15877951192392845,58.931037226472164,12.799186602347126,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350Q1K-V5,LG Electronics Inc,Mono-c-Si,0,350.0,325.5,1.6732799999999999,,,60.0,10.39,42.9,9.68,36.2,0.00329363,-0.1041183,49.01,1.506196768745851,10.406736488972573,4.2910988933898324e-12,0.19527339665480822,121.22551735653889,4.39618110220423,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG350S2W-A5,LG Electronics Inc,Mono-c-Si,0,350.0,317.2,2.012016,2.004,1.004,72.0,10.02,46.3,9.44,37.1,0.003006,-0.1389,47.6,1.7887624747467081,10.028414372069584,5.700407498791597e-11,0.4098742876956809,488.08640470357096,4.267366047614587,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355A1C-A5,LG Electronics Inc,Mono-c-Si,0,355.0,332.8,1.67,,,60.0,10.78,42.7,9.79,36.3,0.0032339999999999995,-0.10248,45.7,1.5465121606865584,10.805455825771864,1.0329482822952065e-11,0.14706719615744993,62.2798250524562,13.226486772767801,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355M1C-N5,LG Electronics Inc,Mono-c-Si,0,355.0,331.9,1.7255,,,60.0,10.8,41.5,10.25,34.7,0.0034149600000000007,-0.10682100000000001,44.94,1.5052730311088303,10.805121360658955,1.1385429215864127e-11,0.20423460126389537,430.6928234434327,6.117818272122578,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355M1K-A6,LG Electronics Inc,Mono-c-Si,0,355.0,328.7,1.81,,,60.0,10.84,41.6,10.37,34.3,0.0031761199999999997,-0.10811840000000002,47.15,1.4962585365383567,10.840004153178915,9.130102933947578e-12,0.25731013781411405,671599.7707281547,3.19197894257447,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1C-A6,LG Electronics Inc,Mono-c-Si,0,355.0,328.3,1.81308,,,60.0,11.19,41.4,10.54,33.7,0.00267441,-0.1070604,47.43,1.479165594031991,11.204542226278818,7.708423107027143e-12,0.2974684866326902,228.89702832502408,2.163160522592637,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1C-E6,LG Electronics Inc,Mono-c-Si,0,355.0,328.3,1.79,,,60.0,11.15,39.8,10.65,33.4,0.0027206,-0.10399739999999998,47.8,1.4284582515028275,11.15105669646156,8.832753889825679e-12,0.17997830639469756,1899.0866733098244,2.2007871521812645,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1C-L5,LG Electronics Inc,Mono-c-Si,0,355.0,329.7,1.7254999999999998,,,60.0,10.8,41.2,10.29,34.5,0.0025120800000000003,-0.10646080000000002,46.48,1.4877338509686024,10.8024976452315,1.0106916300208821e-11,0.1985072635483985,858.3598852486256,4.784886007755628,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1C-N5,LG Electronics Inc,Mono-c-Si,0,355.0,331.9,1.7254999999999998,,,60.0,10.8,41.5,10.25,34.7,0.0034149600000000007,-0.10682100000000001,44.94,1.5052730311088303,10.805121360658955,1.1385429215864127e-11,0.20423460126389537,430.6928234434327,6.117818272122578,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1C-V5,LG Electronics Inc,Mono-c-Si,0,355.0,330.6,1.648704,,,60.0,10.65,41.4,9.95,35.7,0.0028158600000000003,-0.10714319999999998,45.95,1.5415199649038414,10.656456523030732,2.2430799024393763e-11,0.07932084120249418,130.83930111101225,11.780622981884811,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1K-A6,LG Electronics Inc,Mono-c-Si,0,355.0,328.7,1.81308,,,60.0,10.84,41.6,10.37,34.3,0.0031761199999999997,-0.10811840000000002,47.15,1.4962585365383567,10.840004153178915,9.130102933947578e-12,0.25731013781411405,671599.7707281547,3.19197894257447,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1K-B6,LG Electronics Inc,Mono-c-Si,0,355.0,328.1,1.81,,,60.0,10.72,41.5,10.15,35.0,0.00299088,-0.106738,48.0,1.5004267443273547,10.726258425205199,1.0297472004463724e-11,0.1746205430427107,299.10595200647333,5.469074038465213,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1K-E6,LG Electronics Inc,Mono-c-Si,0,355.0,329.7,1.79,,,60.0,10.93,40.8,10.44,34.0,0.00280901,-0.10530479999999999,47.2,1.4421835407143313,10.930005037705152,5.652454023767612e-12,0.21802635009535543,473040.6438793645,-0.08360238834204678,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1K-L5,LG Electronics Inc,Mono-c-Si,0,355.0,330.7,1.7254999999999998,,,60.0,10.72,41.2,10.21,34.8,0.00268536,-0.1064196,45.83,1.4910606427036028,10.722695080226348,1.0657339980354975e-11,0.16711317719011326,664.7124113160863,5.32203084556034,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1W-A6,LG Electronics Inc,Mono-c-Si,0,355.0,328.3,1.81308,,,60.0,11.19,41.4,10.54,33.7,0.00267441,-0.1070604,47.43,1.479165594031991,11.204542226278818,7.708423107027143e-12,0.2974684866326902,228.89702832502408,2.163160522592637,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1W-E6,LG Electronics Inc,Mono-c-Si,0,355.0,328.3,1.79,,,60.0,11.15,39.8,10.65,33.4,0.0027206,-0.10399739999999998,47.8,1.4284582515028275,11.15105669646156,8.832753889825679e-12,0.17997830639469756,1899.0866733098244,2.2007871521812645,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1W-L5,LG Electronics Inc,Mono-c-Si,0,355.0,329.7,1.7254999999999998,,,60.0,10.8,41.2,10.29,34.5,0.0025120800000000003,-0.10646080000000002,46.48,1.4877338509686024,10.8024976452315,1.0106916300208821e-11,0.1985072635483985,858.3598852486256,4.784886007755628,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1W-N5,LG Electronics Inc,Mono-c-Si,0,355.0,331.9,1.7254999999999998,,,60.0,10.8,41.5,10.25,34.7,0.0034149600000000007,-0.10682100000000001,44.94,1.5052730311088303,10.805121360658955,1.1385429215864127e-11,0.20423460126389537,430.6928234434327,6.117818272122578,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N1W-V5,LG Electronics Inc,Mono-c-Si,0,355.0,330.6,1.648704,,,60.0,10.65,41.4,9.95,35.7,0.0028158600000000003,-0.10714319999999998,45.95,1.5415199649038414,10.656456523030732,2.2430799024393763e-11,0.07932084120249418,130.83930111101225,11.780622981884811,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N2C-B3,LG Electronics Inc,Mono-c-Si,0,355.0,324.2,1.9012,1.94,0.98,72.0,9.79,48.2,9.32,38.1,0.0019579999999999997,-0.13496000000000002,47.5,1.782969893447412,9.790004922664114,1.779346729707789e-11,0.5027985954966233,999999.5523527361,2.0351858692042066,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG355N2T-A4,LG Electronics Inc,Mono-c-Si,1,355.0,326.5,1.9502,1.99,0.98,72.0,9.66,47.9,9.08,39.1,0.002898,-0.12933,46.8,1.7821369504802544,9.672232504581453,2.019205956377452e-11,0.36888958259473864,291.3118438964635,6.95432177776116,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355N2W-B3,LG Electronics Inc,Mono-c-Si,0,355.0,324.2,1.9012,1.94,0.98,72.0,9.79,48.2,9.32,38.1,0.0019579999999999997,-0.13496000000000002,47.5,1.782969893447412,9.790004922664114,1.779346729707789e-11,0.5027985954966233,999999.5523527361,2.0351858692042066,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG355Q1C-A5,LG Electronics Inc,Mono-c-Si,0,355.0,332.8,1.6732799999999999,1.68,0.996,60.0,10.78,42.7,9.79,36.3,0.0032339999999999995,-0.10248,45.7,1.5465121606865584,10.805455825771864,1.0329482822952065e-11,0.14706719615744993,62.2798250524562,13.226486772767801,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355Q1C-V5,LG Electronics Inc,Mono-c-Si,0,355.0,334.5,1.6732799999999999,,,60.0,10.78,42.7,9.79,36.3,0.003091704,-0.103761,44.53,1.5320973264666007,10.80620836122805,7.963588546928326e-12,0.15047863349614238,61.894738701935715,9.50483113902659,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355Q1K-A5,LG Electronics Inc,Mono-c-Si,0,355.0,330.3,1.6732799999999999,1.68,0.996,60.0,10.79,42.7,9.82,36.4,0.0043159999999999995,-0.10248,48.7,1.5449718804398684,10.812735854735058,1.0080956635838873e-11,0.13617220446573386,64.62471282275796,12.84396460098331,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355Q1K-V5,LG Electronics Inc,Mono-c-Si,0,355.0,330.3,1.6732799999999999,,,60.0,10.44,43.1,9.76,36.4,0.0033094799999999996,-0.10460370000000001,49.01,1.5113771960570952,10.454577493834769,4.1811498461157175e-12,0.19201661721509394,137.517018204864,4.117715227453956,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG355S2W-A5,LG Electronics Inc,Mono-c-Si,0,355.0,321.9,2.012016,2.004,1.004,72.0,10.07,46.4,9.5,37.4,0.0030210000000000002,-0.1392,47.6,1.797097636522956,10.077006949852539,6.115657149905581e-11,0.38164864668555254,548.4843182546055,4.813127167359981,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360A1C-A5,LG Electronics Inc,Mono-c-Si,0,360.0,337.6,1.67,,,60.0,10.79,42.7,9.87,36.5,0.003237,-0.10248,45.7,1.545037111024358,10.808903602459857,1.0151719856513384e-11,0.12518870295426995,71.45654426239992,13.026431605158624,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360A1K-V5,LG Electronics Inc,Mono-c-Si,0,360.0,335.1,1.67,,,60.0,10.5,43.3,9.82,36.7,0.0033285,-0.1050891,49.01,1.520725220303726,10.5133808482917,4.394057062398704e-12,0.1766613222071364,138.6267779185291,4.492816536428419,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360M1C-N5,LG Electronics Inc,Mono-c-Si,0,360.0,336.7,1.7255,,,60.0,10.84,41.6,10.28,35.1,0.003427608,-0.10707840000000002,44.94,1.2343574954874252,10.840168924196787,1.0040863195071893e-13,0.24418134620182724,15637.385400975038,5.319027276549141,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360M1K-A6,LG Electronics Inc,Mono-c-Si,0,360.0,333.4,1.81,,,60.0,10.88,41.7,10.39,34.7,0.0031878400000000004,-0.10837830000000002,47.15,1.5053258903262376,10.880519810089796,1.0130279721613492e-11,0.22244883675406382,4656.013777043005,4.039135356566942,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1C-A6,LG Electronics Inc,Mono-c-Si,0,360.0,333.1,1.81308,,,60.0,11.23,41.5,10.56,34.1,0.0026839700000000004,-0.10731900000000001,47.43,1.490765068383872,11.245224643932987,8.968044112865091e-12,0.26252318220394016,193.642318331757,3.409477459700537,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1C-E6,LG Electronics Inc,Mono-c-Si,0,360.0,333.0,1.79,,,60.0,11.19,40.2,10.68,33.8,0.0027303600000000003,-0.1050426,47.8,1.444664108212308,11.191626949133308,9.176511203571485e-12,0.17420362393676894,1198.1558263452257,2.4927491820995122,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1C-L5,LG Electronics Inc,Mono-c-Si,0,360.0,334.5,1.7254999999999998,,,60.0,10.84,41.3,10.32,34.9,0.0025213839999999998,-0.1067192,46.48,1.4985472105958146,10.84288888414218,1.1568255767273072e-11,0.16318687053772787,612.3283614316318,5.913810802785561,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1C-N5,LG Electronics Inc,Mono-c-Si,0,360.0,336.7,1.7254999999999998,,,60.0,10.84,41.6,10.28,35.1,0.003427608,-0.10707840000000002,44.94,1.2343574954874252,10.840168924196787,1.0040863195071893e-13,0.24418134620182724,15637.385400975038,5.319027276549141,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1K-A6,LG Electronics Inc,Mono-c-Si,0,360.0,333.4,1.81308,,,60.0,10.88,41.7,10.39,34.7,0.0031878400000000004,-0.10837830000000002,47.15,1.5053258903262376,10.880519810089796,1.0130279721613492e-11,0.22244883675406382,4656.013777043005,4.039135356566942,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1K-B6,LG Electronics Inc,Mono-c-Si,0,360.0,332.9,1.81,,,60.0,10.76,41.6,10.18,35.4,0.00300204,-0.1069952,48.0,1.5112509582229476,10.765628636893798,1.1773548314535704e-11,0.13889595641825755,265.52080782402123,6.59643418258894,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1K-E6,LG Electronics Inc,Mono-c-Si,0,360.0,334.5,1.79,,,60.0,11.03,41.0,10.51,34.3,0.00283471,-0.10582100000000001,47.2,1.4500761858844649,11.030006219258224,5.796496727616914e-12,0.20322038192919542,360115.6502986283,0.04741168201935271,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1W-A6,LG Electronics Inc,Mono-c-Si,0,360.0,333.1,1.81308,,,60.0,11.23,41.5,10.56,34.1,0.0026839700000000004,-0.10731900000000001,47.43,1.490765068383872,11.245224643932987,8.968044112865091e-12,0.26252318220394016,193.642318331757,3.409477459700537,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1W-E6,LG Electronics Inc,Mono-c-Si,0,360.0,333.0,1.79,,,60.0,11.19,40.2,10.68,33.8,0.0027303600000000003,-0.1050426,47.8,1.444664108212308,11.191626949133308,9.176511203571485e-12,0.17420362393676894,1198.1558263452257,2.4927491820995122,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1W-L5,LG Electronics Inc,Mono-c-Si,0,360.0,334.5,1.7254999999999998,,,60.0,10.84,41.3,10.32,34.9,0.0025213839999999998,-0.1067192,46.48,1.4985472105958146,10.84288888414218,1.1568255767273072e-11,0.16318687053772787,612.3283614316318,5.913810802785561,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N1W-N5,LG Electronics Inc,Mono-c-Si,0,360.0,336.7,1.7254999999999998,,,60.0,10.84,41.6,10.28,35.1,0.003427608,-0.10707840000000002,44.94,1.2343574954874252,10.840168924196787,1.0040863195071893e-13,0.24418134620182724,15637.385400975038,5.319027276549141,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N2C-B3,LG Electronics Inc,Mono-c-Si,0,360.0,328.9,1.9012,1.94,0.98,72.0,9.84,48.3,9.39,38.4,0.001968,-0.13524,47.5,1.792780606343641,9.840004578819668,1.9610854626975613e-11,0.4653027949164033,999998.3382054452,2.796012899021965,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG360N2C-G4,LG Electronics Inc,Mono-c-Si,0,360.0,332.6,1.9012,1.94,0.98,72.0,9.86,47.4,9.33,38.6,0.0029579999999999997,-0.13272,45.9,1.7579788908607588,9.866299029685274,1.908689239481859e-11,0.3685306247702346,576.8685364198519,2.4518483253634784,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N2K-G4,LG Electronics Inc,Mono-c-Si,0,360.0,332.9,1.9012,1.94,0.98,72.0,9.69,47.9,9.21,39.1,0.002907,-0.13412000000000002,45.7,1.7749552423210566,9.692137875352893,1.8407657533367855e-11,0.3672516372544505,1664.5818742656213,2.2779009680755555,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N2T-A4,LG Electronics Inc,Mono-c-Si,1,360.0,331.2,1.9502,1.99,0.98,72.0,9.7,48.2,9.12,39.5,0.0029099999999999994,-0.13014,46.8,1.7966941668076837,9.711651932002855,2.1330125210414143e-11,0.3500220872704431,291.3863795810808,7.393469998950241,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360N2W-B3,LG Electronics Inc,Mono-c-Si,0,360.0,328.9,1.9012,1.94,0.98,72.0,9.84,48.3,9.39,38.4,0.001968,-0.13524,47.5,1.792780606343641,9.840004578819668,1.9610854626975613e-11,0.4653027949164033,999998.3382054452,2.796012899021965,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG360N2W-G4,LG Electronics Inc,Mono-c-Si,0,360.0,332.6,1.9012,1.94,0.98,72.0,9.86,47.4,9.33,38.6,0.0029579999999999997,-0.13272,45.9,1.7579788908607588,9.866299029685274,1.908689239481859e-11,0.3685306247702346,576.8685364198519,2.4518483253634784,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360Q1C-A5,LG Electronics Inc,Mono-c-Si,0,360.0,337.6,1.6732799999999999,1.68,0.996,60.0,10.79,42.7,9.86,36.5,0.003237,-0.10248,45.7,1.5458453927497884,10.809267636256177,1.028714115533539e-11,0.12496445407687311,69.98089653324558,13.153081499140546,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360Q1C-V5,LG Electronics Inc,Mono-c-Si,0,360.0,339.3,1.6732799999999999,,,60.0,10.79,42.7,9.87,36.5,0.003094572,-0.103761,44.53,1.530642861228292,10.809552780279589,7.825536042728689e-12,0.12857454313648367,70.95253468034622,9.309492371225106,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360Q1K-A5,LG Electronics Inc,Mono-c-Si,0,360.0,335.1,1.6732799999999999,1.68,0.996,60.0,10.8,42.8,9.9,36.6,0.004320000000000001,-0.10271999999999999,48.7,1.5453359767454011,10.81800202243825,9.598576214417551e-12,0.1246078500821427,74.7563003316389,12.3536973590034,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360Q1K-V5,LG Electronics Inc,Mono-c-Si,0,360.0,335.1,1.6732799999999999,,,60.0,10.5,43.3,9.82,36.7,0.0033285,-0.1050891,49.01,1.520725220303726,10.5133808482917,4.394057062398704e-12,0.1766613222071364,138.6267779185291,4.492816536428419,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG360S2W-A5,LG Electronics Inc,Mono-c-Si,0,360.0,326.6,2.012016,2.004,1.004,72.0,10.12,46.6,9.56,37.7,0.0030359999999999996,-0.1398,47.6,1.8072154059279293,10.125690081361006,6.365293288438233e-11,0.364449107683507,648.1849743043541,5.1047120037592775,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365A1C-A5,LG Electronics Inc,Mono-c-Si,0,365.0,342.4,1.67,,,60.0,10.8,42.8,9.95,36.7,0.0032400000000000003,-0.10271999999999999,45.7,1.5454195480371393,10.814637783757039,9.668552697808141e-12,0.1137621000668075,83.93556716650848,12.537639912403074,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365A1C-V5,LG Electronics Inc,Mono-c-Si,0,365.0,344.2,1.67,,,60.0,10.8,42.8,9.95,36.7,0.0030974400000000003,-0.104004,44.53,1.531035417675932,10.815195461458996,7.450841624126668e-12,0.11711968582870311,83.24144435933724,8.832831471781235,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365A1K-V5,LG Electronics Inc,Mono-c-Si,0,365.0,339.9,1.67,,,60.0,10.55,43.5,9.9,36.9,0.0033443500000000003,-0.1055745,49.01,1.5259185587813164,10.561458361307105,4.28322811287762e-12,0.17359851561052766,159.83649774884046,4.218209410850423,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365M1C-N5,LG Electronics Inc,Mono-c-Si,0,365.0,341.5,1.7255,,,60.0,10.88,41.7,10.3,35.5,0.0034402560000000005,-0.10733580000000002,44.94,1.5278657207875148,10.885084647378731,1.5058058317745597e-11,0.13325138836461586,285.1279556398435,8.50495961088602,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365M1K-A6,LG Electronics Inc,Mono-c-Si,0,365.0,338.2,1.81,,,60.0,10.92,41.8,10.41,35.1,0.00319956,-0.1086382,47.15,1.5168724728168108,10.922056023902035,1.1719451327867349e-11,0.1872713491152162,994.6397662934829,5.257238465124047,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1C-A6,LG Electronics Inc,Mono-c-Si,0,365.0,337.8,1.81308,,,60.0,11.27,41.6,10.58,34.5,0.00269353,-0.10757760000000001,47.43,1.502405697499823,11.285213624301894,1.041758475101183e-11,0.2277295052454534,168.69823265840853,4.656272840204592,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1C-E6,LG Electronics Inc,Mono-c-Si,0,365.0,337.8,1.79,,,60.0,11.25,40.5,10.73,34.1,0.002745,-0.1058265,47.8,1.4568972907697544,11.252093255773667,9.476472953956284e-12,0.1694285946855073,910.5775498088171,2.7199098015627823,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1C-L5,LG Electronics Inc,Mono-c-Si,0,365.0,339.3,1.7254999999999998,,,60.0,10.88,41.4,10.34,35.3,0.002530688,-0.1069776,46.48,1.5100763588224457,10.883320911112465,1.3373880049829558e-11,0.12793861183394048,419.15370172361423,7.144998964349889,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1C-N5,LG Electronics Inc,Mono-c-Si,0,365.0,341.5,1.7254999999999998,,,60.0,10.88,41.7,10.3,35.5,0.0034402560000000005,-0.10733580000000002,44.94,1.5278657207875148,10.885084647378731,1.5058058317745597e-11,0.13325138836461586,285.1279556398435,8.50495961088602,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1K-A6,LG Electronics Inc,Mono-c-Si,0,365.0,338.2,1.81308,,,60.0,10.92,41.8,10.41,35.1,0.00319956,-0.1086382,47.15,1.5168724728168108,10.922056023902035,1.1719451327867349e-11,0.1872713491152162,994.6397662934829,5.257238465124047,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1K-B6,LG Electronics Inc,Mono-c-Si,0,365.0,337.6,1.81,,,60.0,10.8,41.7,10.21,35.8,0.0030132000000000006,-0.1072524,48.0,1.5220807048036493,10.804658245266697,1.3437673493646972e-11,0.10340939680308107,239.75154269908182,7.7193633004044,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1K-E6,LG Electronics Inc,Mono-c-Si,0,365.0,339.3,1.79,,,60.0,11.13,41.2,10.6,34.5,0.0028604100000000003,-0.1063372,47.2,1.4634262675478307,11.133427701429927,6.567185445850448e-12,0.1978008545905157,642.2738840676828,1.0185696862852018,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1W-A6,LG Electronics Inc,Mono-c-Si,0,365.0,337.8,1.81308,,,60.0,11.27,41.6,10.58,34.5,0.00269353,-0.10757760000000001,47.43,1.502405697499823,11.285213624301894,1.041758475101183e-11,0.2277295052454534,168.69823265840853,4.656272840204592,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1W-E6,LG Electronics Inc,Mono-c-Si,0,365.0,337.8,1.79,,,60.0,11.25,40.5,10.73,34.1,0.002745,-0.1058265,47.8,1.4568972907697544,11.252093255773667,9.476472953956284e-12,0.1694285946855073,910.5775498088171,2.7199098015627823,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1W-L5,LG Electronics Inc,Mono-c-Si,0,365.0,339.3,1.7254999999999998,,,60.0,10.88,41.4,10.34,35.3,0.002530688,-0.1069776,46.48,1.5100763588224457,10.883320911112465,1.3373880049829558e-11,0.12793861183394048,419.15370172361423,7.144998964349889,-0.3467,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N1W-N5,LG Electronics Inc,Mono-c-Si,0,365.0,341.5,1.7254999999999998,,,60.0,10.88,41.7,10.3,35.5,0.0034402560000000005,-0.10733580000000002,44.94,1.5278657207875148,10.885084647378731,1.5058058317745597e-11,0.13325138836461586,285.1279556398435,8.50495961088602,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N2C-B3,LG Electronics Inc,Mono-c-Si,0,365.0,333.6,1.9012,1.94,0.98,72.0,9.89,48.4,9.46,38.6,0.001978,-0.13552,47.5,1.8006318772708219,9.890004343062428,2.0969893364724814e-11,0.4391095493427,999987.094838984,3.3102791714289057,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG365N2C-G4,LG Electronics Inc,Mono-c-Si,0,365.0,337.4,1.9012,1.94,0.98,72.0,9.92,47.7,9.39,38.9,0.002976,-0.13356,45.9,1.7701127132721342,9.926007323592957,1.950490769199681e-11,0.3617655717064126,597.3899179091411,2.580092846450137,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N2K-G4,LG Electronics Inc,Mono-c-Si,0,365.0,337.6,1.9012,1.94,0.98,72.0,9.76,48.2,9.27,39.4,0.002928,-0.13496000000000002,45.7,1.7879337865452478,9.762853937498921,1.9050539489711155e-11,0.3600448636868804,1231.2946636715465,2.5058622811718827,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N2T-A4,LG Electronics Inc,Mono-c-Si,1,365.0,335.9,1.9502,1.99,0.98,72.0,9.74,48.5,9.16,39.9,0.002922,-0.13095,46.8,1.8112432914245429,9.75106644753437,2.2511086015360943e-11,0.33133223533469164,291.6180639330631,7.826188938555471,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365N2W-B3,LG Electronics Inc,Mono-c-Si,0,365.0,333.6,1.9012,1.94,0.98,72.0,9.89,48.4,9.46,38.6,0.001978,-0.13552,47.5,1.8006318772708219,9.890004343062428,2.0969893364724814e-11,0.4391095493427,999987.094838984,3.3102791714289057,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG365N2W-G4,LG Electronics Inc,Mono-c-Si,0,365.0,337.4,1.9012,1.94,0.98,72.0,9.92,47.7,9.39,38.9,0.002976,-0.13356,45.9,1.7701127132721342,9.926007323592957,1.950490769199681e-11,0.3617655717064126,597.3899179091411,2.580092846450137,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365Q1C-A5,LG Electronics Inc,Mono-c-Si,0,365.0,342.4,1.6732799999999999,1.68,0.996,60.0,10.8,42.8,9.94,36.8,0.0032400000000000003,-0.10271999999999999,45.7,1.548313244897449,10.813475680573463,1.0167801901008908e-11,0.10205265426190138,81.7894621416665,13.005156165444355,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365Q1C-V5,LG Electronics Inc,Mono-c-Si,0,365.0,344.1,1.6732799999999999,,,60.0,10.8,42.8,9.95,36.7,0.0030974400000000003,-0.104004,44.53,1.531035417675932,10.815195461458996,7.450841624126668e-12,0.11711968582870311,83.24144435933724,8.832831471781235,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365Q1K-V5,LG Electronics Inc,Mono-c-Si,0,365.0,339.9,1.6732799999999999,,,60.0,10.55,43.5,9.9,36.9,0.0033443500000000003,-0.1055745,49.01,1.5259185587813164,10.561458361307105,4.28322811287762e-12,0.17359851561052766,159.83649774884046,4.218209410850423,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG365S2W-A5,LG Electronics Inc,Mono-c-Si,0,365.0,331.3,2.012016,2.004,1.004,72.0,10.18,46.7,9.61,38.0,0.003054,-0.1401,47.6,1.8173236939391066,10.18643994882225,6.984614914709474e-11,0.33652903617338825,531.9709326631465,5.846609296481307,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370A1C-A5,LG Electronics Inc,Mono-c-Si,0,370.0,347.2,1.67,,,60.0,10.82,42.8,10.01,37.0,0.003246,-0.10271999999999999,45.7,1.5484073249606773,10.829374936744335,1.0261524026807813e-11,0.080307325780589,92.68598670115234,13.049238286255921,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370A1C-V5,LG Electronics Inc,Mono-c-Si,0,370.0,349.0,1.67,,,60.0,10.82,42.8,10.01,37.0,0.003103176,-0.104004,44.53,1.5339843255866328,10.82985606442694,7.910183040743292e-12,0.08366905957291253,91.85199954015467,9.331056401338763,-0.3134,N,2025.7.3,6/23/2025,4.0,bootstrapping +LG Electronics Inc LG370M1C-N5,LG Electronics Inc,Mono-c-Si,0,370.0,346.3,1.7255,,,60.0,10.92,41.8,10.34,35.8,0.0034529040000000006,-0.1075932,44.94,1.5359553863595157,10.924257735648377,1.6345337474463303e-11,0.10939100833580251,280.5598832501297,9.196948178407045,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370M1K-A6,LG Electronics Inc,Mono-c-Si,0,370.0,343.0,1.81,,,60.0,19.96,41.9,10.43,35.5,0.00584828,-0.1088981,47.15,2.2854794780341936,20.000000143221794,9.99999979371762e-08,0.007929741692432596,3.9569276459011293,99.99999871833359,-0.3442,N,2025.7.3,6/23/2025,2.0,bootstrapping +LG Electronics Inc LG370N1C-A6,LG Electronics Inc,Mono-c-Si,0,370.0,342.6,1.81308,,,60.0,11.31,41.7,10.61,34.9,0.0027030900000000004,-0.10783620000000001,47.43,1.5133941892723675,11.323877346954614,1.1944947627147931e-11,0.19317401875379,157.43629998304107,5.8004157080016965,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1C-E6,LG Electronics Inc,Mono-c-Si,0,370.0,342.6,1.79,,,60.0,11.3,40.9,10.76,34.4,0.0027572000000000004,-0.10687169999999999,47.8,1.4716541760590567,11.30318560969418,9.567515016257803e-12,0.17408755179652527,617.5236581396351,2.769998778537881,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1C-N5,LG Electronics Inc,Mono-c-Si,0,370.0,346.3,1.7254999999999998,,,60.0,10.92,41.8,10.34,35.8,0.0034529040000000006,-0.1075932,44.94,1.5359553863595157,10.924257735648377,1.6345337474463303e-11,0.10939100833580251,280.5598832501297,9.196948178407045,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1K-A6,LG Electronics Inc,Mono-c-Si,0,370.0,342.9,1.81308,,,60.0,10.96,41.9,10.43,35.5,0.0032112800000000004,-0.1088981,47.15,1.5207939712303045,10.960005299799246,1.1868215320186389e-11,0.15378512345363068,318029.5204729095,5.318964567392819,-0.3442,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1K-B6,LG Electronics Inc,Mono-c-Si,0,370.0,342.4,1.81,,,60.0,10.84,41.8,10.24,36.2,0.0030243600000000002,-0.10750959999999998,48.0,1.532915526506428,10.84336818348304,1.531059386654187e-11,0.06815727878725367,219.35411412520546,8.837816285159008,-0.3383,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1K-E6,LG Electronics Inc,Mono-c-Si,0,370.0,344.1,1.79,,,60.0,11.23,41.4,10.68,34.7,0.0028861100000000003,-0.10685339999999999,47.2,1.472164800149054,11.234473499220865,6.824629758412996e-12,0.19341911750720805,485.547575519341,1.2687490643816952,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1W-A6,LG Electronics Inc,Mono-c-Si,0,370.0,342.6,1.81308,,,60.0,11.31,41.7,10.61,34.9,0.0027030900000000004,-0.10783620000000001,47.43,1.5133941892723675,11.323877346954614,1.1944947627147931e-11,0.19317401875379,157.43629998304107,5.8004157080016965,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1W-E6,LG Electronics Inc,Mono-c-Si,0,370.0,342.6,1.79,,,60.0,11.3,40.9,10.76,34.4,0.0027572000000000004,-0.10687169999999999,47.8,1.4716541760590567,11.30318560969418,9.567515016257803e-12,0.17408755179652527,617.5236581396351,2.769998778537881,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N1W-N5,LG Electronics Inc,Mono-c-Si,0,370.0,346.3,1.7254999999999998,,,60.0,10.92,41.8,10.34,35.8,0.0034529040000000006,-0.1075932,44.94,1.5359553863595157,10.924257735648377,1.6345337474463303e-11,0.10939100833580251,280.5598832501297,9.196948178407045,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N2C-B3,LG Electronics Inc,Mono-c-Si,0,370.0,338.3,1.9012,1.94,0.98,72.0,9.94,48.5,9.54,38.8,0.001988,-0.1358,47.5,1.8092697231951953,9.940004294721403,2.2673294176032703e-11,0.40743155499866635,943028.9803484664,3.9199490561507306,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG370N2C-G4,LG Electronics Inc,Mono-c-Si,0,370.0,342.1,1.9012,1.94,0.98,72.0,9.98,48.0,9.44,39.2,0.0029939999999999997,-0.13440000000000002,45.9,1.7831400902942514,9.986705577355409,2.0172790422526747e-11,0.3550844448015526,528.4769072076509,2.8129488275117267,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N2K-G4,LG Electronics Inc,Mono-c-Si,0,370.0,342.4,1.9012,1.94,0.98,72.0,9.82,48.5,9.33,39.7,0.0029460000000000003,-0.1358,45.7,1.8000506225226076,9.822635641672974,1.9458147861039916e-11,0.35330210025678893,1316.3499463773576,2.6295997405938687,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N2T-A4,LG Electronics Inc,Mono-c-Si,1,370.0,340.6,1.9502,1.99,0.98,72.0,9.78,48.8,9.2,40.3,0.002934,-0.13176000000000002,46.8,1.825784455074144,9.79047738829181,2.373561169338163e-11,0.31281729884213916,291.9957844036328,8.25261486137559,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N2T-A5,LG Electronics Inc,Mono-c-Si,0,370.0,340.1,2.04,2.04,1.0,72.0,9.99,48.8,9.33,39.7,0.002997,-0.12688,47.8,1.7841908458523605,10.010440439937128,1.2900516908389098e-11,0.38793409190988254,189.59775861531122,6.874995795394519,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370N2W-B3,LG Electronics Inc,Mono-c-Si,0,370.0,338.3,1.9012,1.94,0.98,72.0,9.94,48.5,9.54,38.8,0.001988,-0.1358,47.5,1.8092697231951953,9.940004294721403,2.2673294176032703e-11,0.40743155499866635,943028.9803484664,3.9199490561507306,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG370N2W-G4,LG Electronics Inc,Mono-c-Si,0,370.0,342.1,1.9012,1.94,0.98,72.0,9.98,48.0,9.44,39.2,0.0029939999999999997,-0.13440000000000002,45.9,1.7831400902942514,9.986705577355409,2.0172790422526747e-11,0.3550844448015526,528.4769072076509,2.8129488275117267,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370Q1C-A5,LG Electronics Inc,Mono-c-Si,0,370.0,347.2,1.6732799999999999,1.68,0.996,60.0,10.82,42.8,10.01,37.0,0.003246,-0.10271999999999999,45.7,1.5484073249606773,10.829374936744335,1.0261524026807813e-11,0.080307325780589,92.68598670115234,13.049238286255921,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370Q1C-V5,LG Electronics Inc,Mono-c-Si,0,370.0,349.0,1.6732799999999999,,,60.0,10.82,42.8,10.01,37.0,0.003103176,-0.104004,44.53,1.5339843255866328,10.82985606442694,7.910183040743292e-12,0.08366905957291253,91.85199954015467,9.331056401338763,-0.3134,N,2025.7.3,6/23/2025,4.0,bootstrapping +LG Electronics Inc LG370Q1K-V5,LG Electronics Inc,Mono-c-Si,0,370.0,344.7,1.6732799999999999,,,60.0,10.61,43.7,9.97,37.2,0.00336337,-0.10605990000000001,49.01,1.5345175277225305,10.619966985529068,4.441971610907861e-12,0.1587420458075194,168.9831997165261,4.475715508190867,-0.3064,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG370S2W-A5,LG Electronics Inc,Mono-c-Si,0,370.0,335.9,2.012016,2.004,1.004,72.0,10.23,46.9,9.67,38.3,0.003069,-0.1407,47.6,1.827413321244537,10.235236291120492,7.258840678891361e-11,0.3198381343320923,624.8591348811726,6.128625752376105,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375A1C-V5,LG Electronics Inc,Mono-c-Si,0,375.0,353.8,1.67,,,60.0,10.83,42.8,10.09,37.2,0.003106044,-0.104004,44.53,1.5326066487771646,10.836053969772772,7.7821105007916e-12,0.06279475524372284,112.3340923894918,9.145341429566432,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375M1C-A6,LG Electronics Inc,Mono-c-Si,0,375.0,347.3,1.81308,,,60.0,11.35,41.8,10.63,35.3,0.00271265,-0.10809479999999999,47.43,1.525097685935389,11.362720519053319,1.383163674303542e-11,0.15871526827493226,141.61515672470898,7.045412954755767,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375M1K-A6,LG Electronics Inc,Mono-c-Si,0,375.0,346.1,1.79,,,60.0,11.0,42.0,10.45,35.9,0.0028599999999999997,-0.1071,48.71,1.5300502028463496,11.003395076392273,1.3055920673506688e-11,0.11954636850370809,387.32856299894416,8.237619766224974,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N1C-A6,LG Electronics Inc,Mono-c-Si,0,375.0,347.3,1.81308,,,60.0,11.35,41.8,10.63,35.3,0.00271265,-0.10809479999999999,47.43,1.525097685935389,11.362720519053319,1.383163674303542e-11,0.15871526827493226,141.61515672470898,7.045412954755767,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N1C-E6,LG Electronics Inc,Mono-c-Si,0,375.0,347.3,1.79,,,60.0,11.35,41.3,10.8,34.8,0.0027694000000000004,-0.10791689999999998,47.8,1.4878654997360956,11.353610401710178,9.93207710706468e-12,0.16823108845192,528.8671514172057,3.0495296539418986,-0.3405,N,2025.7.3,6/23/2025,4.0,bootstrapping +LG Electronics Inc LG375N1K-A6,LG Electronics Inc,Mono-c-Si,0,375.0,346.1,1.79,,,60.0,11.0,42.0,10.45,35.9,0.0028599999999999997,-0.1071,48.71,1.5300502028463496,11.003395076392273,1.3055920673506688e-11,0.11954636850370809,387.32856299894416,8.237619766224974,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N1K-E6,LG Electronics Inc,Mono-c-Si,0,375.0,348.8,1.79,,,60.0,11.33,41.5,10.75,34.9,0.00291181,-0.10711150000000001,47.2,1.4797107929782811,11.33595824675352,7.405381486550219e-12,0.179672190747788,341.658547030096,1.883154866447165,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N1W-A6,LG Electronics Inc,Mono-c-Si,0,375.0,347.3,1.81308,,,60.0,11.35,41.8,10.63,35.3,0.00271265,-0.10809479999999999,47.43,1.525097685935389,11.362720519053319,1.383163674303542e-11,0.15871526827493226,141.61515672470898,7.045412954755767,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N1W-E6,LG Electronics Inc,Mono-c-Si,0,375.0,347.3,1.79,,,60.0,11.35,41.3,10.8,34.8,0.0027694000000000004,-0.10791689999999998,47.8,1.4878654997360956,11.353610401710178,9.93207710706468e-12,0.16823108845192,528.8671514172057,3.0495296539418986,-0.3405,N,2025.7.3,6/23/2025,4.0,bootstrapping +LG Electronics Inc LG375N2C-B3,LG Electronics Inc,Mono-c-Si,0,375.0,343.1,1.9012,1.94,0.98,72.0,9.99,48.6,9.62,39.0,0.001998,-0.13608000000000003,47.5,1.8178948371746704,9.990003954053202,2.4492850342177783e-11,0.37508548427553096,947701.2072184281,4.525545320027598,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG375N2C-G4,LG Electronics Inc,Mono-c-Si,0,375.0,346.9,1.9012,1.94,0.98,72.0,10.04,48.3,9.5,39.5,0.0030119999999999995,-0.13524,45.9,1.795271778307138,10.046409484023066,2.0601948495328942e-11,0.3484859123617346,545.8783601341092,2.9371058139840858,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N2K-A5,LG Electronics Inc,Mono-c-Si,0,375.0,346.0,2.0,2.0,1.0,72.0,10.09,48.9,9.62,39.0,0.003027,-0.12714,47.2,1.7525515546028991,10.090004746758838,7.693583525559077e-12,0.47043093218616205,999999.3877829486,2.3113049145423945,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG375N2K-G4,LG Electronics Inc,Mono-c-Si,0,375.0,347.1,1.9012,1.94,0.98,72.0,9.88,48.8,9.38,40.0,0.0029640000000000005,-0.13664,45.7,1.813079288981303,9.88335281442383,2.0115520541710873e-11,0.34662619331322925,1021.4300646310064,2.8584830723017385,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N2T-A4,LG Electronics Inc,Mono-c-Si,1,375.0,345.4,1.9502,1.99,0.98,72.0,9.82,49.1,9.24,40.6,0.0029460000000000003,-0.13257000000000002,46.8,1.8379936501676728,9.830177970865117,2.4180761151362918e-11,0.3069551259386833,296.159164625306,8.378680831134037,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N2T-A5,LG Electronics Inc,Mono-c-Si,0,375.0,344.8,2.04,2.04,1.0,72.0,10.03,48.9,9.34,40.2,0.003009,-0.12714,47.8,1.799930135336786,10.050846276615134,1.5492452769282147e-11,0.3354955394020908,161.4206857211497,8.453754506665739,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375N2W-B3,LG Electronics Inc,Mono-c-Si,0,375.0,343.1,1.9012,1.94,0.98,72.0,9.99,48.6,9.62,39.0,0.001998,-0.13608000000000003,47.5,1.8178948371746704,9.990003954053202,2.4492850342177783e-11,0.37508548427553096,947701.2072184281,4.525545320027598,-0.39,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG375N2W-G4,LG Electronics Inc,Mono-c-Si,0,375.0,346.9,1.9012,1.94,0.98,72.0,10.04,48.3,9.5,39.5,0.0030119999999999995,-0.13524,45.9,1.795271778307138,10.046409484023066,2.0601948495328942e-11,0.3484859123617346,545.8783601341092,2.9371058139840858,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375Q1C-V5,LG Electronics Inc,Mono-c-Si,0,375.0,353.8,1.6732799999999999,,,60.0,10.83,42.8,10.09,37.2,0.003106044,-0.104004,44.53,1.5326066487771646,10.836053969772772,7.7821105007916e-12,0.06279475524372284,112.3340923894918,9.145341429566432,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG375Q1K-A6,LG Electronics Inc,Mono-c-Si,0,375.0,351.7,1.81,,,60.0,10.84,43.4,10.12,37.0,0.0032628399999999995,-0.1048544,46.26,1.52739848290274,10.852880681264748,4.7990044963403795e-12,0.14763086745059364,124.24176729284575,5.490354236495907,-0.3068,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380A1C-V5,LG Electronics Inc,Mono-c-Si,0,380.0,358.7,1.67,,,60.0,10.84,42.9,10.17,37.4,0.003108912,-0.10424699999999999,44.53,1.5331120048389935,10.84389429932875,7.423572059044193e-12,0.05209141948541907,144.99937987032916,8.685350926884897,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380M1C-A6,LG Electronics Inc,Mono-c-Si,0,380.0,352.1,1.81308,,,60.0,11.39,41.9,10.65,35.7,0.00272221,-0.10835339999999999,47.43,1.5368401932755102,11.40097319404316,1.5992385339114756e-11,0.12440003377682159,129.1252466934544,8.290553349900977,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380M1K-A6,LG Electronics Inc,Mono-c-Si,0,380.0,350.8,1.79,,,60.0,11.04,42.1,10.47,36.3,0.0028704,-0.107355,48.71,1.526662282730693,11.04000314302329,1.165850193620849e-11,0.0879376107899313,308885.532760174,7.1774120630510145,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N1C-A6,LG Electronics Inc,Mono-c-Si,0,380.0,352.1,1.81308,,,60.0,11.39,41.9,10.65,35.7,0.00272221,-0.10835339999999999,47.43,1.5368401932755102,11.40097319404316,1.5992385339114756e-11,0.12440003377682159,129.1252466934544,8.290553349900977,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N1C-E6,LG Electronics Inc,Mono-c-Si,0,380.0,352.1,1.79,,,60.0,11.39,41.7,10.85,35.1,0.00277916,-0.1089621,47.8,1.5007253653623844,11.392936129198159,9.698695742470974e-12,0.1732731217924578,672.1709909855896,2.8158733694300175,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N1K-A6,LG Electronics Inc,Mono-c-Si,0,380.0,350.8,1.79,,,60.0,11.04,42.1,10.47,36.3,0.0028704,-0.107355,48.71,1.526662282730693,11.04000314302329,1.165850193620849e-11,0.0879376107899313,308885.532760174,7.1774120630510145,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N1K-E6,LG Electronics Inc,Mono-c-Si,0,380.0,353.6,1.79,,,60.0,11.43,41.7,10.83,35.2,0.00293751,-0.1076277,47.2,1.4905106949577576,11.43655423590645,7.989207976794688e-12,0.1649550002957414,287.6667373794026,2.4488904064074912,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N1W-A6,LG Electronics Inc,Mono-c-Si,0,380.0,352.1,1.81308,,,60.0,11.39,41.9,10.65,35.7,0.00272221,-0.10835339999999999,47.43,1.5368401932755102,11.40097319404316,1.5992385339114756e-11,0.12440003377682159,129.1252466934544,8.290553349900977,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N1W-E6,LG Electronics Inc,Mono-c-Si,0,380.0,352.1,1.79,,,60.0,11.39,41.7,10.85,35.1,0.00277916,-0.1089621,47.8,1.5007253653623844,11.392936129198159,9.698695742470974e-12,0.1732731217924578,672.1709909855896,2.8158733694300175,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2C-A5,LG Electronics Inc,Mono-c-Si,0,380.0,349.5,2.0,2.0,1.0,72.0,10.31,48.9,9.75,39.0,0.0030930000000000003,-0.12714,47.7,1.770244187099093,10.317677362610763,1.0318908008890803e-11,0.46650145519167546,626.469054313228,4.6242174059616765,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2C-G4,LG Electronics Inc,Mono-c-Si,0,380.0,351.6,1.9012,1.94,0.98,72.0,10.1,48.6,9.55,39.8,0.0030299999999999997,-0.13608000000000003,45.9,1.808304313192426,10.10706328307576,2.129272698868006e-11,0.3419510028068934,488.96598808034844,3.1655131291351166,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2K-A5,LG Electronics Inc,Mono-c-Si,0,380.0,350.7,2.0,2.0,1.0,72.0,10.13,49.0,9.65,39.4,0.0030390000000000005,-0.1274,47.2,1.7614153851691916,10.130005867412798,8.397878444603082e-12,0.4395076695521985,758815.5825208597,3.0096866083629523,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2K-G4,LG Electronics Inc,Mono-c-Si,0,380.0,351.9,1.9012,1.94,0.98,72.0,9.94,49.1,9.43,40.3,0.002982,-0.13748000000000002,45.7,1.8261133331956618,9.944038271473664,2.0787885044664338e-11,0.3400195832905585,836.9409469580318,3.0852109071676472,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2T-A4,LG Electronics Inc,Mono-c-Si,1,380.0,350.1,1.9502,1.99,0.98,72.0,9.86,49.4,9.28,41.0,0.0029579999999999997,-0.13338,46.8,1.8525226612286625,9.869594975184848,2.5460431461998866e-11,0.288721555043398,296.6963963375297,8.795099382070818,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2T-A5,LG Electronics Inc,Mono-c-Si,0,380.0,349.6,2.04,2.04,1.0,72.0,10.07,49.0,9.37,40.6,0.0030210000000000002,-0.1274,47.8,1.8115630271375827,10.089395132121513,1.7494689447625833e-11,0.2957106069514217,153.53367043636098,9.496904361880281,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2W-A5,LG Electronics Inc,Mono-c-Si,0,380.0,349.5,2.0,2.0,1.0,72.0,10.31,48.9,9.75,39.0,0.0030930000000000003,-0.12714,47.7,1.770244187099093,10.317677362610763,1.0318908008890803e-11,0.46650145519167546,626.469054313228,4.6242174059616765,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2W-G4,LG Electronics Inc,Mono-c-Si,0,380.0,351.6,1.9012,1.94,0.98,72.0,10.1,48.6,9.55,39.8,0.0030299999999999997,-0.13608000000000003,45.9,1.808304313192426,10.10706328307576,2.129272698868006e-11,0.3419510028068934,488.96598808034844,3.1655131291351166,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380N2W-V5,LG Electronics Inc,Mono-c-Si,0,380.0,349.0,2.0,,,72.0,10.31,48.9,9.75,39.0,0.002301192,-0.125673,48.88,1.7292955157912357,10.319187652793174,5.3585600782550985e-12,0.47553840144570414,533.6293256644518,0.46456422952283327,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380Q1C-V5,LG Electronics Inc,Mono-c-Si,0,380.0,358.7,1.6732799999999999,,,60.0,10.84,42.9,10.17,37.4,0.003108912,-0.10424699999999999,44.53,1.5331120048389935,10.84389429932875,7.423572059044193e-12,0.05209141948541907,144.99937987032916,8.685350926884897,-0.3134,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG380Q1K-A6,LG Electronics Inc,Mono-c-Si,0,380.0,356.5,1.81,,,60.0,10.85,43.5,10.21,37.2,0.00326585,-0.10509600000000001,46.26,1.5273840159913803,10.858501312054866,4.538568295169434e-12,0.13634820573312448,174.01761314116263,4.964785340775834,-0.3068,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385M1C-A6,LG Electronics Inc,Mono-c-Si,0,385.0,356.9,1.81308,,,60.0,11.43,42.0,10.67,36.1,0.00273177,-0.108612,47.43,1.5486210692476612,11.438665198288934,1.8463231885239623e-11,0.09022601746090722,119.0144007408126,9.535710427339383,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N1C-A6,LG Electronics Inc,Mono-c-Si,0,385.0,356.9,1.81308,,,60.0,11.43,42.0,10.67,36.1,0.00273177,-0.108612,47.43,1.5486210692476612,11.438665198288934,1.8463231885239623e-11,0.09022601746090722,119.0144007408126,9.535710427339383,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N1C-E6,LG Electronics Inc,Mono-c-Si,0,385.0,356.9,1.79,,,60.0,11.44,42.0,10.88,35.5,0.00279136,-0.10974599999999998,47.8,1.5070303357778578,11.440007342941104,9.013682743219718e-12,0.15981134118471163,248980.21414214215,2.1488258483327485,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N1W-A6,LG Electronics Inc,Mono-c-Si,0,385.0,356.9,1.81308,,,60.0,11.43,42.0,10.67,36.1,0.00273177,-0.108612,47.43,1.5486210692476612,11.438665198288934,1.8463231885239623e-11,0.09022601746090722,119.0144007408126,9.535710427339383,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N1W-E6,LG Electronics Inc,Mono-c-Si,0,385.0,356.9,1.79,,,60.0,11.44,42.0,10.88,35.5,0.00279136,-0.10974599999999998,47.8,1.5070303357778578,11.440007342941104,9.013682743219718e-12,0.15981134118471163,248980.21414214215,2.1488258483327485,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2C-A5,LG Electronics Inc,Mono-c-Si,0,385.0,354.2,2.0,2.0,1.0,72.0,10.35,49.0,9.78,39.4,0.0031049999999999997,-0.1274,47.7,1.7817275708038056,10.3589082964877,1.1680372490747e-11,0.4279294898194298,497.1848755496918,5.655490120730446,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2C-G4,LG Electronics Inc,Mono-c-Si,0,385.0,356.4,1.9012,1.94,0.98,72.0,10.16,48.9,9.61,40.1,0.0030480000000000004,-0.13692000000000001,45.9,1.820433890052727,10.16676354343885,2.173291515508246e-11,0.33551309970090104,503.99811630238656,3.2857376341048137,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2K-A5,LG Electronics Inc,Mono-c-Si,0,385.0,355.5,2.0,2.0,1.0,72.0,10.17,49.1,9.68,39.8,0.003051,-0.12766000000000002,47.2,1.772138545984428,10.171338989826857,9.41562837957786e-12,0.40086490212815307,3044.680571928744,3.944055509998582,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2T-A5,LG Electronics Inc,Mono-c-Si,0,385.0,354.3,2.04,2.04,1.0,72.0,10.11,49.1,9.4,41.0,0.0030329999999999997,-0.12766000000000002,47.8,1.8232022387230844,10.1276634388583,1.9727918579682932e-11,0.2562091794458105,146.64612085216598,10.536761914309126,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2T-J5,LG Electronics Inc,Mono-c-Si,0,385.0,351.8,2.0,,,72.0,10.1,49.4,9.56,40.3,0.00224422,-0.1271556,50.66,1.7564306964647043,10.108252937698326,6.1025004111192996e-12,0.38397148431146294,469.90685686483846,1.5545764147523273,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2W-A5,LG Electronics Inc,Mono-c-Si,0,385.0,354.2,2.0,2.0,1.0,72.0,10.35,49.0,9.78,39.4,0.0031049999999999997,-0.1274,47.7,1.7817275708038056,10.3589082964877,1.1680372490747e-11,0.4279294898194298,497.1848755496918,5.655490120730446,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2W-G4,LG Electronics Inc,Mono-c-Si,0,385.0,356.4,1.9012,1.94,0.98,72.0,10.16,48.9,9.61,40.1,0.0030480000000000004,-0.13692000000000001,45.9,1.820433890052727,10.16676354343885,2.173291515508246e-11,0.33551309970090104,503.99811630238656,3.2857376341048137,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385N2W-V5,LG Electronics Inc,Mono-c-Si,0,385.0,353.7,2.0,,,72.0,10.35,49.0,9.78,39.4,0.0023101199999999997,-0.12593000000000001,48.88,1.7403218249095957,10.360331762450562,6.0643865821515615e-12,0.4371006555168003,437.8722250477937,1.4579784481788003,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG385Q1K-A6,LG Electronics Inc,Mono-c-Si,0,385.0,361.3,1.81,,,60.0,10.86,43.7,10.3,37.4,0.0032688599999999997,-0.10557920000000001,46.26,1.529307825445739,10.8650186168724,4.169026342562122e-12,0.13495788217721919,292.0411419433302,4.191301672986699,-0.3068,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N2T-V5,LG Electronics Inc,Mono-c-Si,0,385.0,351.8,2.0,,,72.0,10.1,49.4,9.56,40.3,0.00224422,-0.1271556,50.66,1.7564306964647043,10.108252937698326,6.1025004111192996e-12,0.38397148431146294,469.90685686483846,1.5545764147523273,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N1C-E6,LG Electronics Inc,Mono-c-Si,0,390.0,361.7,1.79,,,60.0,11.49,42.4,10.92,35.8,0.00280356,-0.11079119999999999,47.8,1.5298961829063427,11.494321960158087,1.0485758366795839e-11,0.16283779106415855,432.9068637537278,3.407762401097395,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N1K-E6,LG Electronics Inc,Mono-c-Si,0,390.0,363.2,1.79,,,60.0,11.63,42.1,10.99,35.5,0.0029889100000000004,-0.10866010000000001,47.2,1.5059536920555319,11.638515873597624,8.27860171123575e-12,0.16728612841688648,228.46014048680243,2.613131554408222,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N1W-E6,LG Electronics Inc,Mono-c-Si,0,390.0,361.7,1.79,,,60.0,11.49,42.4,10.92,35.8,0.00280356,-0.11079119999999999,47.8,1.5298961829063427,11.494321960158087,1.0485758366795839e-11,0.16283779106415855,432.9068637537278,3.407762401097395,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2C-A5,LG Electronics Inc,Mono-c-Si,0,390.0,358.9,2.0,2.0,1.0,72.0,10.39,49.1,9.81,39.8,0.003117,-0.12766000000000002,47.7,1.793220222805258,10.399755551092039,1.3203099342175924e-11,0.3896275123729841,414.9667729098191,6.683908953760896,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2K-A5,LG Electronics Inc,Mono-c-Si,0,390.0,360.2,2.0,2.0,1.0,72.0,10.21,49.2,9.71,40.2,0.003063,-0.12792,47.2,1.7790275685725734,10.210009171892233,9.962417767588464e-12,0.3632754129121192,401490.1092196241,4.382761392943501,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2T-A5,LG Electronics Inc,Mono-c-Si,0,390.0,359.0,2.04,2.04,1.0,72.0,10.15,49.2,9.43,41.4,0.003045,-0.12792,47.8,1.834847314912495,10.165666724578463,2.2215331719647884e-11,0.2169871381609186,140.57944584409984,11.573233358878378,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2T-J5,LG Electronics Inc,Mono-c-Si,0,390.0,356.5,2.0,,,72.0,10.14,49.5,9.59,40.7,0.002253108,-0.127413,50.66,1.7673829510159527,10.148735292975212,6.879946220026527e-12,0.34519482939022395,400.7050019537857,2.524405036698478,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2W-A5,LG Electronics Inc,Mono-c-Si,0,390.0,358.9,2.0,2.0,1.0,72.0,10.39,49.1,9.81,39.8,0.003117,-0.12766000000000002,47.7,1.793220222805258,10.399755551092039,1.3203099342175924e-11,0.3896275123729841,414.9667729098191,6.683908953760896,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2W-L5,LG Electronics Inc,Mono-c-Si,0,390.0,362.1,2.072576,,,72.0,10.39,49.1,9.81,39.8,0.0026058120000000003,-0.126678,46.17,1.7462650367683874,10.401263857245333,6.314962512517508e-12,0.40006946926059117,369.0318261266152,1.3344853429705796,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N2W-N5,LG Electronics Inc,Mono-c-Si,0,390.0,362.3,2.072576,,,72.0,10.36,49.0,10.02,39.0,0.002392124,-0.126077,46.17,1.7240676601869245,10.360004463474052,4.701165465444541e-12,0.4100870553844484,951847.6759348109,-0.7995092510641387,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG390N2W-V5,LG Electronics Inc,Mono-c-Si,0,390.0,358.5,2.0,,,72.0,10.39,49.1,9.81,39.8,0.002319048,-0.12618700000000002,48.88,1.7513629568446758,10.401096665270904,6.854502106476564e-12,0.39893070882605663,373.5256964669966,2.449425523140905,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390N3K-V6,LG Electronics Inc,Mono-c-Si,1,390.0,362.3,1.9,,,66.0,11.08,45.0,10.72,36.4,0.00372842,-0.11970000000000001,46.23,1.6333393800873068,11.080003369390571,1.2004004213261455e-11,0.2801037444315838,921119.527492204,2.8391567707087875,-0.3497,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG390Q1C-A6,LG Electronics Inc,Mono-c-Si,0,390.0,364.2,1.81,,,60.0,11.26,43.5,10.63,36.7,0.0030289400000000004,-0.10509600000000001,47.68,1.5156240186810388,11.269880503963172,3.794876573098548e-12,0.18523977851737397,211.10258302386305,3.147401779455546,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG390Q1K-A6,LG Electronics Inc,Mono-c-Si,0,390.0,366.1,1.81,,,60.0,10.87,43.9,10.39,37.5,0.0032718699999999996,-0.1060624,46.26,1.5294429034938828,10.871687081470645,3.704591070586066e-12,0.14444120721094708,930.6461815043443,3.1403696760580826,-0.3068,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415N2T-V5,LG Electronics Inc,Mono-c-Si,0,390.0,356.5,2.0,,,72.0,10.14,49.5,9.59,40.7,0.002253108,-0.127413,50.66,1.7673829510159527,10.148735292975212,6.879946220026527e-12,0.34519482939022395,400.7050019537857,2.524405036698478,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395A1C-A6,LG Electronics Inc,Mono-c-Si,0,395.0,369.0,1.81308,,,60.0,11.29,43.6,10.69,37.0,0.00303701,-0.1053376,47.68,1.5049212995258066,11.290006571591165,2.9544450993909606e-12,0.1658261192581041,284889.7501318621,0.9530369711548278,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N1C-E6,LG Electronics Inc,Mono-c-Si,0,395.0,366.4,1.79,,,60.0,11.53,42.7,10.96,36.0,0.0028133200000000002,-0.1115751,47.8,1.5394742324781487,11.534303284681288,1.0292286601586608e-11,0.16899215604947637,452.7889091241457,3.221081813621356,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N1W-E6,LG Electronics Inc,Mono-c-Si,0,395.0,366.4,1.79,,,60.0,11.53,42.7,10.96,36.0,0.0028133200000000002,-0.1115751,47.8,1.5394742324781487,11.534303284681288,1.0292286601586608e-11,0.16899215604947637,452.7889091241457,3.221081813621356,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2C-A5,LG Electronics Inc,Mono-c-Si,0,395.0,363.7,2.0,2.0,1.0,72.0,10.43,49.2,9.83,40.2,0.003129,-0.12792,47.7,1.8055815815848806,10.441232450851427,1.5080573173528022e-11,0.3515934016894383,326.47542914628195,7.81689065811814,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2K-A5,LG Electronics Inc,Mono-c-Si,0,395.0,365.0,2.0,2.0,1.0,72.0,10.25,49.3,9.74,40.6,0.003075,-0.12818000000000002,47.2,1.7946494964833595,10.253711002980129,1.1973927997166552e-11,0.3241850595545825,895.417474819515,5.938113673197125,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2T-A5,LG Electronics Inc,Mono-c-Si,0,395.0,363.8,2.04,2.04,1.0,72.0,10.19,49.3,9.46,41.8,0.0030569999999999994,-0.12818000000000002,47.8,1.8464977482878053,10.203419355935905,2.498205631751534e-11,0.17804049901201877,135.19521346503623,12.60631731642411,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2T-J5,LG Electronics Inc,Mono-c-Si,0,395.0,361.2,2.0,,,72.0,10.18,49.6,9.62,41.1,0.002261996,-0.12767040000000002,50.66,1.7783494178572365,10.188896799916249,7.747100957188154e-12,0.3066879623712795,350.9219532196275,3.4923270637200403,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2W-A5,LG Electronics Inc,Mono-c-Si,0,395.0,363.7,2.0,2.0,1.0,72.0,10.43,49.2,9.83,40.2,0.003129,-0.12792,47.7,1.8055815815848806,10.441232450851427,1.5080573173528022e-11,0.3515934016894383,326.47542914628195,7.81689065811814,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2W-L5,LG Electronics Inc,Mono-c-Si,0,395.0,366.9,2.072576,,,72.0,10.43,49.2,9.83,40.2,0.0026158440000000004,-0.12693600000000002,46.17,1.758103652205239,10.442681874343487,7.215862380051657e-12,0.3621992892470679,297.884874940419,2.4201885376031655,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N2W-N5,LG Electronics Inc,Mono-c-Si,0,395.0,367.0,2.072576,,,72.0,10.4,49.1,10.06,39.3,0.00240136,-0.1263343,46.17,1.731595836311046,10.400004200921313,5.040351587735888e-12,0.3853554083993812,954013.9468871155,-0.26500213167125897,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG395N2W-V5,LG Electronics Inc,Mono-c-Si,0,395.0,363.2,2.0,,,72.0,10.43,49.2,9.83,40.2,0.002327976,-0.12644400000000003,48.88,1.763241810309908,10.442521568748347,7.830036087279274e-12,0.36104635404228713,300.73815557084583,3.5431190790913742,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG395N3C-V6,LG Electronics Inc,Mono-c-Si,1,395.0,364.8,1.9,,,66.0,11.3,44.6,10.89,36.3,0.0035369000000000004,-0.11861370000000002,47.8,1.6195821505416321,11.300003326487372,1.2401937374003729e-11,0.2689317232243671,913573.4058270431,2.998520030913138,-0.35145,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG395N3K-V6,LG Electronics Inc,Mono-c-Si,1,395.0,367.1,1.9,,,66.0,11.12,45.1,10.74,36.8,0.0037418799999999995,-0.119966,46.23,1.6417617671715685,11.120003093249933,1.3056321367527063e-11,0.25667659006800286,922750.9449410556,3.5125696315922164,-0.3497,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG395N3W-V6,LG Electronics Inc,Mono-c-Si,1,395.0,364.8,1.9,,,66.0,11.3,44.6,10.89,36.3,0.0035369000000000004,-0.11861370000000002,47.8,1.6195821505416321,11.300003326487372,1.2401937374003729e-11,0.2689317232243671,913573.4058270431,2.998520030913138,-0.35145,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG395Q1C-A6,LG Electronics Inc,Mono-c-Si,0,395.0,369.0,1.81,,,60.0,11.29,43.6,10.69,37.0,0.00303701,-0.1053376,47.68,1.5049212995258066,11.290006571591165,2.9544450993909606e-12,0.1658261192581041,284889.7501318621,0.9530369711548278,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420N2T-V5,LG Electronics Inc,Mono-c-Si,0,395.0,361.2,2.0,,,72.0,10.18,49.6,9.62,41.1,0.002261996,-0.12767040000000002,50.66,1.7783494178572365,10.188896799916249,7.747100957188154e-12,0.3066879623712795,350.9219532196275,3.4923270637200403,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400A1C-A6,LG Electronics Inc,Mono-c-Si,0,400.0,373.8,1.81308,,,60.0,11.32,43.8,10.76,37.2,0.0030450800000000004,-0.1058208,47.68,1.514668825768747,11.320005371311831,3.1279225345363065e-12,0.162398143224075,342253.358515618,1.405914476832218,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N1C-E6,LG Electronics Inc,Mono-c-Si,0,400.0,371.2,1.79,,,60.0,11.58,43.0,10.99,36.4,0.00282552,-0.11235899999999999,47.8,1.5424685100491389,11.58000557324274,9.051198536549425e-12,0.15631324989484754,324786.49924804707,2.0823551487627534,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N1W-E6,LG Electronics Inc,Mono-c-Si,0,400.0,371.2,1.79,,,60.0,11.58,43.0,10.99,36.4,0.00282552,-0.11235899999999999,47.8,1.5424685100491389,11.58000557324274,9.051198536549425e-12,0.15631324989484754,324786.49924804707,2.0823551487627534,-0.3405,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2C-A5,LG Electronics Inc,Mono-c-Si,0,400.0,368.4,2.0,2.0,1.0,72.0,10.47,49.3,9.86,40.6,0.003141,-0.12818000000000002,47.7,1.8171076320373154,10.48126245123813,1.7001891104191307e-11,0.313772780913785,291.6950291878419,8.84133343753759,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2K-A5,LG Electronics Inc,Mono-c-Si,0,400.0,369.7,2.0,2.0,1.0,72.0,10.29,49.4,9.76,41.0,0.0030869999999999995,-0.12844,47.2,1.8067900834405002,10.295163118750454,1.3639100318955666e-11,0.28616925025428774,570.3300186776503,7.039727999198167,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2T-A5,LG Electronics Inc,Mono-c-Si,0,400.0,368.5,2.04,2.04,1.0,72.0,10.23,49.4,9.49,42.2,0.003069,-0.12844,47.8,1.8581531027026954,10.240934646456155,2.805530275921665e-11,0.13936542241662242,130.38448762077795,13.635956984037225,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2T-J5,LG Electronics Inc,Mono-c-Si,0,400.0,366.0,2.0,,,72.0,10.22,49.7,9.65,41.5,0.0022708840000000004,-0.12792780000000004,50.66,1.789329613736144,10.228754403197795,8.71314312637232e-12,0.26844692611294413,313.38830675142276,4.4582114925179095,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2T-L5,LG Electronics Inc,Mono-c-Si,1,400.0,370.5,2.0725,,,72.0,10.38,49.2,9.74,41.1,0.00356034,-0.1329384,46.0,1.8379545507781834,10.391548595954124,2.4080197223136836e-11,0.2449913141173566,220.20078167862056,7.740386092222478,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2W-A5,LG Electronics Inc,Mono-c-Si,0,400.0,368.4,2.0,2.0,1.0,72.0,10.47,49.3,9.86,40.6,0.003141,-0.12818000000000002,47.7,1.8171076320373154,10.48126245123813,1.7001891104191307e-11,0.313772780913785,291.6950291878419,8.84133343753759,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2W-L5,LG Electronics Inc,Mono-c-Si,0,400.0,371.7,2.072576,,,72.0,10.47,49.3,9.86,40.6,0.0026258760000000005,-0.127194,46.17,1.7691499205587278,10.48262862466558,8.13857423446087e-12,0.3245189407792589,269.04856329848786,3.401978416591443,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N2W-N5,LG Electronics Inc,Mono-c-Si,0,400.0,371.8,2.072576,,,72.0,10.44,49.2,10.09,39.7,0.0024105959999999997,-0.1265916,46.17,1.7402219005573376,10.440003886083144,5.498111146425114e-12,0.3558906528558233,956113.125225493,0.4133996423001504,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG400N2W-V5,LG Electronics Inc,Mono-c-Si,0,400.0,367.9,2.0,,,72.0,10.47,49.3,9.86,40.6,0.0023369040000000003,-0.126701,48.88,1.7743266023927702,10.48247771546643,8.829085219920842e-12,0.32335377109374513,271.3248275459946,4.532265003342767,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG400N3C-V6,LG Electronics Inc,Mono-c-Si,1,400.0,369.6,1.9,,,66.0,11.35,44.8,10.9,36.7,0.0035525500000000002,-0.11914559999999999,47.8,1.6288903587962253,11.35000324116282,1.2895120696109123e-11,0.2607569483326087,913144.9115760116,3.2878515153021945,-0.35145,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG400N3K-V6,LG Electronics Inc,Mono-c-Si,1,400.0,371.9,1.9,,,66.0,11.16,45.2,10.76,37.2,0.0037553400000000002,-0.120232,46.23,1.6501625341873591,11.160002812082775,1.4183959864602282e-11,0.23299872179205589,924693.6852692649,4.1799900074109875,-0.3497,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG400N3W-V6,LG Electronics Inc,Mono-c-Si,1,400.0,369.6,1.9,,,66.0,11.35,44.8,10.9,36.7,0.0035525500000000002,-0.11914559999999999,47.8,1.6288903587962253,11.35000324116282,1.2895120696109123e-11,0.2607569483326087,913144.9115760116,3.2878515153021945,-0.35145,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG400Q1C-A6,LG Electronics Inc,Mono-c-Si,0,400.0,373.8,1.81,,,60.0,11.32,43.8,10.76,37.2,0.0030450800000000004,-0.1058208,47.68,1.514668825768747,11.320005371311831,3.1279225345363065e-12,0.162398143224075,342253.358515618,1.405914476832218,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG425N2T-B5,LG Electronics Inc,Mono-c-Si,1,400.0,370.5,2.0725,,,72.0,10.38,49.2,9.74,41.1,0.00356034,-0.1329384,46.0,1.8379545507781834,10.391548595954124,2.4080197223136836e-11,0.2449913141173566,220.20078167862056,7.740386092222478,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG425N2T-V5,LG Electronics Inc,Mono-c-Si,0,400.0,366.0,2.0,,,72.0,10.22,49.7,9.65,41.5,0.0022708840000000004,-0.12792780000000004,50.66,1.789329613736144,10.228754403197795,8.71314312637232e-12,0.26844692611294413,313.38830675142276,4.4582114925179095,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405A1C-A6,LG Electronics Inc,Mono-c-Si,0,405.0,378.6,1.81308,,,60.0,11.35,43.9,10.82,37.5,0.00305315,-0.1060624,47.68,1.5234127027717,11.350005952623974,3.4671936912568427e-12,0.13952555273640807,266036.74554107507,2.2456188760011306,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2C-A5,LG Electronics Inc,Mono-c-Si,0,405.0,373.2,2.0,2.0,1.0,72.0,10.51,49.4,9.89,41.0,0.003153,-0.12844,47.7,1.8286405585415377,10.52097236929833,1.9141936258314186e-11,0.276210661396518,264.5712538233033,9.862636179172865,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2K-A5,LG Electronics Inc,Mono-c-Si,0,405.0,374.5,2.0,2.0,1.0,72.0,10.33,49.5,9.79,41.4,0.0030989999999999998,-0.1287,47.2,1.8180834607672434,10.335415215538237,1.5332387165358156e-11,0.24843989488810286,473.9209581980503,8.031642327654701,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2T-J5,LG Electronics Inc,Mono-c-Si,0,405.0,370.7,2.0,,,72.0,10.26,49.8,9.68,41.9,0.002279772,-0.1281852,50.66,1.8003230333055704,10.268323805108338,9.788054467287182e-12,0.23046788511433308,284.0768690933539,5.422025935197541,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2T-L5,LG Electronics Inc,Mono-c-Si,1,405.0,375.3,2.0725,,,72.0,10.42,49.3,9.76,41.5,0.0035740599999999996,-0.13320859999999998,46.0,1.8506258822025223,10.43105308935154,2.7430417910809106e-11,0.20698191393171672,195.12658283921502,8.856881958133531,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2W-A5,LG Electronics Inc,Mono-c-Si,0,405.0,373.2,2.0,2.0,1.0,72.0,10.51,49.4,9.89,41.0,0.003153,-0.12844,47.7,1.8286405585415377,10.52097236929833,1.9141936258314186e-11,0.276210661396518,264.5712538233033,9.862636179172865,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2W-L5,LG Electronics Inc,Mono-c-Si,0,405.0,376.4,2.072576,,,72.0,10.51,49.4,9.89,41.0,0.002635908,-0.127452,46.17,1.7802071635776933,10.522259662748887,9.167597791282625e-12,0.28709513392089986,246.12177401155657,4.381331044068887,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N2W-N5,LG Electronics Inc,Mono-c-Si,0,405.0,376.6,2.072576,,,72.0,10.48,49.3,10.12,40.1,0.0024198320000000002,-0.1268489,46.17,1.7488390475933988,10.480003570376114,5.991580795923295e-12,0.3265078287730229,958396.0971869653,1.0878781455256623,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG405N2W-V5,LG Electronics Inc,Mono-c-Si,0,405.0,372.7,2.0,,,72.0,10.51,49.4,9.89,41.0,0.002345832,-0.12695800000000002,48.88,1.785424455259833,10.522117554083232,9.943274523966418e-12,0.28591738890051244,247.98660740488666,5.519224127655645,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N3C-V6,LG Electronics Inc,Mono-c-Si,1,405.0,374.4,1.9,,,66.0,11.4,45.0,10.92,37.1,0.0035682,-0.1196775,47.8,1.6388452907455955,11.400004805043363,1.3548433612644939e-11,0.26078832195608187,618731.1322477312,3.6656782276422546,-0.35145,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405N3K-V6,LG Electronics Inc,Mono-c-Si,1,405.0,376.6,1.9,,,66.0,11.2,45.28,10.78,37.6,0.0037687999999999997,-0.12044480000000002,46.23,1.658119359195472,11.200002505430028,1.546972047072543e-11,0.20737980025732444,927065.1336948493,4.884833799276097,-0.3497,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG405N3W-V6,LG Electronics Inc,Mono-c-Si,1,405.0,374.4,1.9,,,66.0,11.4,45.0,10.92,37.1,0.0035682,-0.1196775,47.8,1.6388452907455955,11.400004805043363,1.3548433612644939e-11,0.26078832195608187,618731.1322477312,3.6656782276422546,-0.35145,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG405Q1C-A6,LG Electronics Inc,Mono-c-Si,0,405.0,378.6,1.81,,,60.0,11.35,43.9,10.82,37.5,0.00305315,-0.1060624,47.68,1.5234127027717,11.350005952623974,3.4671936912568427e-12,0.13952555273640807,266036.74554107507,2.2456188760011306,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430N2T-B5,LG Electronics Inc,Mono-c-Si,1,405.0,375.3,2.0725,,,72.0,10.42,49.3,9.76,41.5,0.0035740599999999996,-0.13320859999999998,46.0,1.8506258822025223,10.43105308935154,2.7430417910809106e-11,0.20698191393171672,195.12658283921502,8.856881958133531,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430N2T-V5,LG Electronics Inc,Mono-c-Si,0,405.0,370.7,2.0,,,72.0,10.26,49.8,9.68,41.9,0.002279772,-0.1281852,50.66,1.8003230333055704,10.268323805108338,9.788054467287182e-12,0.23046788511433308,284.0768690933539,5.422025935197541,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N2C-A5,LG Electronics Inc,Mono-c-Si,0,410.0,377.9,2.0,2.0,1.0,72.0,10.55,49.5,9.91,41.4,0.0031650000000000003,-0.1287,47.7,1.841092181663437,10.561031938827474,2.178532818536172e-11,0.238767226866315,228.3364961847641,10.994286856029134,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N2T-L5,LG Electronics Inc,Mono-c-Si,1,410.0,380.1,2.0725,,,72.0,10.46,49.4,9.79,41.9,0.00358778,-0.1334788,46.0,1.862362663128015,10.469626076719432,3.0817475757678235e-11,0.16937197361643577,184.04495462522397,9.856928227330371,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N2W-A5,LG Electronics Inc,Mono-c-Si,0,410.0,377.9,2.0,2.0,1.0,72.0,10.55,49.5,9.91,41.4,0.0031650000000000003,-0.1287,47.7,1.841092181663437,10.561031938827474,2.178532818536172e-11,0.238767226866315,228.3364961847641,10.994286856029134,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N2W-L5,LG Electronics Inc,Mono-c-Si,0,410.0,381.2,2.072576,,,72.0,10.55,49.5,9.91,41.4,0.0026459400000000003,-0.12771,46.17,1.792144113477957,10.562274744499668,1.0440519902408796e-11,0.24981145027863666,214.71003392598396,5.467364116717879,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N2W-N5,LG Electronics Inc,Mono-c-Si,0,410.0,381.3,2.072576,,,72.0,10.52,49.4,10.16,40.4,0.002429068,-0.12710619999999997,46.17,1.756367393237411,10.52000331118076,6.411292667973617e-12,0.30238065223172605,960706.7252866158,1.6153689849239246,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG410N2W-V5,LG Electronics Inc,Mono-c-Si,0,410.0,377.4,2.0,,,72.0,10.55,49.5,9.91,41.4,0.00235476,-0.127215,48.88,1.7974088152322678,10.56213761840005,1.1321758331360338e-11,0.24861824181661213,216.0986097045175,6.6141292486843986,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N3C-V6,LG Electronics Inc,Mono-c-Si,1,410.0,379.1,1.9,,,66.0,11.44,45.2,10.94,37.5,0.0035807200000000003,-0.120232,47.8,1.6495690741189903,11.440099424440774,1.4395348900462572e-11,0.23688017356295343,27255.987166104234,4.1277141924178276,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N3K-V6,LG Electronics Inc,Mono-c-Si,1,410.0,381.4,1.9,,,66.0,11.24,45.4,10.79,38.0,0.00378226,-0.12076400000000001,46.23,1.6662619910534109,11.240003799260467,1.6508543650106555e-11,0.20592265938107823,609224.0833809604,5.408050657635926,-0.3497,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG410N3W-V6,LG Electronics Inc,Mono-c-Si,1,410.0,379.1,1.9,,,66.0,11.44,45.2,10.94,37.5,0.0035807200000000003,-0.12020940000000001,47.8,1.6492928247026304,11.440004506544206,1.433129632938407e-11,0.23693285018681923,601469.2527056267,4.109237196122169,-0.35145,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG435N2T-B5,LG Electronics Inc,Mono-c-Si,1,410.0,380.1,2.0725,,,72.0,10.46,49.4,9.79,41.9,0.00358778,-0.1334788,46.0,1.862362663128015,10.469626076719432,3.0817475757678235e-11,0.16937197361643577,184.04495462522397,9.856928227330371,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415N2T-L5,LG Electronics Inc,Mono-c-Si,1,415.0,384.8,2.0725,,,72.0,10.5,49.5,9.82,42.3,0.0036014999999999997,-0.133749,46.0,1.8616156130001074,10.50820928568413,2.8953414808868014e-11,0.13489064795191127,172.53045681282416,9.280105470460715,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415N2W-L5,LG Electronics Inc,Mono-c-Si,0,415.0,386.0,2.072576,,,72.0,10.59,49.6,9.94,41.8,0.002655972,-0.12796800000000003,46.17,1.8032371294079947,10.6012158191404,1.173229559858052e-11,0.2128455393497254,200.96920602597388,6.44344033740472,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415N2W-N5,LG Electronics Inc,Mono-c-Si,0,415.0,386.1,2.072576,,,72.0,10.56,49.5,10.21,40.7,0.002438304,-0.1273635,46.17,1.7645946906652148,10.560002991287732,6.933205844433196e-12,0.2730662328304215,964001.1296658192,2.23316381320695,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG415N2W-V5,LG Electronics Inc,Mono-c-Si,0,415.0,382.2,2.0,,,72.0,10.59,49.6,9.94,41.8,0.0023636879999999996,-0.12747200000000003,48.88,1.8085467848725152,10.601086411722916,1.2720664462438265e-11,0.2116389955075896,202.16251760013122,7.598336028647111,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415N3C-V6,LG Electronics Inc,Mono-c-Si,1,415.0,383.9,1.9,,,66.0,11.49,45.4,10.95,37.9,0.00359637,-0.12074130000000001,47.8,1.6621992767128297,11.491915757299628,1.574230194917152e-11,0.2126617714787154,1275.4662072492672,4.878761673225236,-0.35145,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415N3W-V6,LG Electronics Inc,Mono-c-Si,1,415.0,383.9,1.9,,,66.0,11.49,45.4,10.95,37.9,0.00359637,-0.12074130000000001,47.8,1.6621992767128297,11.491915757299628,1.574230194917152e-11,0.2126617714787154,1275.4662072492672,4.878761673225236,-0.35145,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG415QAK-A6,LG Electronics Inc,Mono-c-Si,0,415.0,386.5,1.99,,,66.0,10.82,47.9,10.08,41.2,0.0034948600000000002,-0.1142894,49.31,1.6773005346475522,10.830936436907903,4.134970092830157e-12,0.12588445137508741,124.54419807745654,5.528634015188662,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG440N2T-B5,LG Electronics Inc,Mono-c-Si,1,415.0,384.8,2.0725,,,72.0,10.5,49.5,9.82,42.3,0.0036014999999999997,-0.133749,46.0,1.8616156130001074,10.50820928568413,2.8953414808868014e-11,0.13489064795191127,172.53045681282416,9.280105470460715,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420N2T-E6,LG Electronics Inc,Mono-c-Si,0,420.0,387.5,2.22,,,72.0,10.82,48.5,10.37,40.5,0.00347322,-0.131726,47.37,1.7800120246360225,10.82000413088314,1.588545091433031e-11,0.2386349454648761,625063.0791375359,3.2420052054386215,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420N2W-L5,LG Electronics Inc,Mono-c-Si,0,420.0,390.8,2.072576,,,72.0,10.63,49.7,9.98,42.1,0.0026660040000000005,-0.128226,46.17,1.8112924714960175,10.639970117621777,1.2591998841818086e-11,0.18778330215916533,200.21193156609357,7.023160475457335,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420N2W-N5,LG Electronics Inc,Mono-c-Si,0,420.0,390.9,2.072576,,,72.0,10.6,49.6,10.23,41.1,0.00244754,-0.1276208,46.17,1.7725028093325454,10.600002739423939,7.45466586265748e-12,0.2495473538220125,965613.461503716,2.806355129242058,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG420N2W-V5,LG Electronics Inc,Mono-c-Si,0,420.0,386.9,2.0,,,72.0,10.63,49.7,9.98,42.1,0.002372616,-0.127729,48.88,1.8166334607257382,10.639848092818054,1.365165381664327e-11,0.1865701655571703,201.38323825183406,8.182907053878987,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420N3C-V6,LG Electronics Inc,Mono-c-Si,1,420.0,388.7,1.9,,,66.0,11.54,45.6,10.97,38.3,0.0036120199999999996,-0.12129600000000001,47.8,1.6683787171009241,11.54000719857827,1.5563122666364683e-11,0.1896675555297361,304056.7662002398,4.713475512416821,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420N3W-V6,LG Electronics Inc,Mono-c-Si,1,420.0,388.7,1.9,,,66.0,11.54,45.6,10.97,38.3,0.0036120199999999996,-0.12129600000000001,47.8,1.6683787171009241,11.54000719857827,1.5563122666364683e-11,0.1896675555297361,304056.7662002398,4.713475512416821,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG420QAK-A6,LG Electronics Inc,Mono-c-Si,0,420.0,391.2,1.99,,,66.0,10.83,48.0,10.19,41.3,0.0034980900000000006,-0.114528,49.31,1.6730847627305006,10.837417869219154,3.670246584530344e-12,0.12664127104565456,184.89473536960844,4.445504380200088,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG425N2T-E6,LG Electronics Inc,Mono-c-Si,0,425.0,392.2,2.22,,,72.0,10.88,48.8,10.42,40.8,0.00349248,-0.13254080000000001,47.37,1.791391522176203,10.880004122345694,1.606346956818037e-11,0.2335359749451615,616372.9564969622,3.2889391350047563,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG425N2W-L5,LG Electronics Inc,Mono-c-Si,0,425.0,395.5,2.072576,,,72.0,10.67,49.8,10.01,42.5,0.002676036,-0.12848400000000001,46.17,1.8223893418812074,10.678550572953768,1.4118505419032223e-11,0.15130664409782318,188.81096097912223,7.992849958748109,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG425N2W-N5,LG Electronics Inc,Mono-c-Si,0,425.0,395.7,2.072576,,,72.0,10.64,49.7,10.26,41.5,0.002456776,-0.1278781,46.17,1.7810992570735404,10.640002425404994,8.0972229568151e-12,0.2207427662564347,968383.6569162742,3.4679086344489507,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG425N2W-V5,LG Electronics Inc,Mono-c-Si,0,425.0,391.7,2.0,,,72.0,10.67,49.8,10.01,42.5,0.002381544,-0.12798600000000002,48.88,1.8277785500820025,10.678435520483086,1.5305079830469737e-11,0.1500796507054268,189.8341200845323,9.16106676134523,-0.3472,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG425QAK-A6,LG Electronics Inc,Mono-c-Si,0,425.0,396.0,1.99,,,66.0,10.84,48.1,10.31,41.3,0.00350132,-0.11476660000000001,49.31,1.6535270789974152,10.840004390731577,2.521663190034333e-12,0.1411703571789287,348526.88741098694,1.162576462965795,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430N2T-E6,LG Electronics Inc,Mono-c-Si,0,430.0,396.9,2.22,,,72.0,10.94,49.1,10.47,41.1,0.0035117399999999997,-0.13335560000000002,47.37,1.8027693948716221,10.940004109969566,1.624143932215889e-11,0.2284868998434202,608198.2573358059,3.335094281870664,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430N2W-E6,LG Electronics Inc,Mono-c-Si,0,430.0,400.0,2.2,,,72.0,11.08,48.6,10.6,40.6,0.00374504,-0.1301022,45.63,1.7743682261478602,11.080004295913598,1.409930236300338e-11,0.23385429713267553,603162.442197028,3.5234451034672793,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430N2W-L5,LG Electronics Inc,Mono-c-Si,0,430.0,400.3,2.072576,,,72.0,10.71,49.9,10.04,42.9,0.0026860680000000007,-0.128742,46.17,1.8183787190715903,10.717191891137396,1.2605193693097866e-11,0.11852615834859985,176.50644787431017,6.98278410655634,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430N2W-N5,LG Electronics Inc,Mono-c-Si,0,430.0,400.5,2.072576,,,72.0,10.68,49.8,10.3,41.8,0.002466012,-0.12813539999999998,46.17,1.7886269559460695,10.680002171407843,8.643462545939946e-12,0.1973809316806413,970819.6580366945,3.9863329920447677,-0.3405,N,2025.7.3,6/23/2025,2.0,first_pass +LG Electronics Inc LG430QAC-A6,LG Electronics Inc,Mono-c-Si,0,430.0,402.1,1.99,,,66.0,11.19,47.9,10.54,40.8,0.0032562900000000002,-0.11457679999999999,47.96,1.6372053571310257,11.190004756448484,2.2008831320082243e-12,0.17188229865258095,404369.9662082422,-0.4353033628614807,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG430QAK-A6,LG Electronics Inc,Mono-c-Si,0,430.0,400.8,1.99,,,66.0,10.85,48.2,10.42,41.3,0.0035045500000000004,-0.11500520000000002,49.31,1.6618846946967727,10.850038228062957,2.750738553913091e-12,0.1494435479231897,42415.50745307283,1.883386660660734,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG435N2T-E6,LG Electronics Inc,Mono-c-Si,0,435.0,401.7,2.22,,,72.0,11.0,49.4,10.51,41.4,0.003531,-0.1341704,47.37,1.8136772769026182,11.000115823229986,1.6301133624944917e-11,0.22363085007413536,21238.740055384806,3.3207812408017365,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG435N2W-E6,LG Electronics Inc,Mono-c-Si,0,435.0,404.8,2.2,,,72.0,11.14,48.8,10.65,40.9,0.00376532,-0.1306376,45.63,1.7835998936947164,11.140004122315668,1.460202177995098e-11,0.21949493242405133,593161.5142762355,3.77244070154425,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG435QAC-A6,LG Electronics Inc,Mono-c-Si,0,435.0,406.9,1.99,,,66.0,11.2,48.0,10.59,41.1,0.0032592,-0.11481599999999999,47.96,1.646500983300971,11.200004086617223,2.4453637851748363e-12,0.14870046985430774,407536.8067969604,0.42738787499378345,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG440N2T-E6,LG Electronics Inc,Mono-c-Si,0,440.0,406.4,2.22,,,72.0,11.06,49.7,10.56,41.7,0.00355026,-0.13498520000000003,47.37,1.8263523474280257,11.060632988366253,1.6785635617309696e-11,0.21842165576619044,3816.410881858571,3.5239928815873576,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG440N2T-F6,LG Electronics Inc,Mono-c-Si,0,440.0,406.9,2.14,,,72.0,11.06,49.7,10.56,41.7,0.00355026,-0.13498520000000003,47.37,1.8263523474280257,11.060632988366253,1.6785635617309696e-11,0.21842165576619044,3816.410881858571,3.5239928815873576,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG440N2W-E6,LG Electronics Inc,Mono-c-Si,0,440.0,409.6,2.2,,,72.0,11.2,49.1,10.7,41.2,0.003785599999999999,-0.13144070000000002,45.63,1.7958197286182773,11.200372880575411,1.4954511386185942e-11,0.214466445593179,6441.80635707795,3.930495497626896,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG440QAC-A6,LG Electronics Inc,Mono-c-Si,0,440.0,411.7,1.99,,,66.0,11.2,48.2,10.64,41.4,0.0032592,-0.1152944,47.96,1.658468410028207,11.200003811061967,2.6750418807368358e-12,0.1351140728705202,397075.46416489437,1.1738840192604187,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG445N2T-E6,LG Electronics Inc,Mono-c-Si,0,445.0,411.2,2.22,,,72.0,11.11,50.0,10.61,42.0,0.003566309999999999,-0.1358,47.37,1.8382426564696621,11.110541588414304,1.7081511262574443e-11,0.21356510054749328,4381.017569415414,3.632111891725902,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG445N2T-F6,LG Electronics Inc,Mono-c-Si,0,445.0,411.6,2.14,,,72.0,11.11,50.0,10.61,42.0,0.003566309999999999,-0.1358,47.37,1.8382426564696621,11.110541588414304,1.7081511262574443e-11,0.21356510054749328,4381.017569415414,3.632111891725902,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG445N2W-E6,LG Electronics Inc,Mono-c-Si,0,445.0,414.4,2.2,,,72.0,11.27,49.4,10.74,41.5,0.0038092599999999996,-0.1322438,45.63,1.8099792685125469,11.272071126638465,1.574240599557353e-11,0.20900880421886212,1137.3178378488842,4.322935907847894,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG445QAC-A6,LG Electronics Inc,Mono-c-Si,0,445.0,416.5,1.99,,,66.0,11.21,48.3,10.7,41.6,0.0032621100000000004,-0.1155336,47.96,1.666828776023259,11.210003604723312,2.9172309754526013e-12,0.12274575512784187,381716.2142314374,1.891506002592604,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG450N2T-E6,LG Electronics Inc,Mono-c-Si,0,450.0,415.9,2.22,,,72.0,11.15,50.3,10.67,42.2,0.0035791499999999997,-0.1366148,47.37,1.8485223531486825,11.150002388350487,1.6971458146623604e-11,0.21419752344606108,999999.879057832,3.5440123693269068,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG450N2T-F6,LG Electronics Inc,Mono-c-Si,0,450.0,416.4,2.14,,,72.0,11.15,50.3,10.67,42.2,0.0035791499999999997,-0.1366148,47.37,1.8485223531486825,11.150002388350487,1.6971458146623604e-11,0.21419752344606108,999999.879057832,3.5440123693269068,-0.3518,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG450N2W-E6,LG Electronics Inc,Mono-c-Si,0,450.0,419.2,2.2,,,72.0,11.34,49.7,10.79,41.8,0.0038329199999999996,-0.13304690000000002,45.63,1.8155576575860475,11.340007369258249,1.4655781134258204e-11,0.20519393413974085,315759.2227922578,3.653763742101241,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG455N2W-E6,LG Electronics Inc,Mono-c-Si,0,455.0,423.9,2.2,,,72.0,11.39,49.9,10.83,42.1,0.0038498199999999995,-0.1335823,45.63,1.824748479988654,11.390006963443614,1.5142553948120553e-11,0.1914107177828288,313089.2003885017,3.8915950336287244,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG460N2W-E6,LG Electronics Inc,Mono-c-Si,0,460.0,428.7,2.2,,,72.0,11.45,50.2,10.86,42.4,0.003870099999999999,-0.1343854,45.63,1.834652374068651,11.450005372643279,1.4982285774672487e-11,0.18707949977408458,398700.1159185324,3.7578286282917603,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG465N2W-E6,LG Electronics Inc,Mono-c-Si,0,465.0,431.8,2.14,,,72.0,11.51,50.5,10.89,42.7,0.0031307199999999996,-0.1288255,48.07,1.7904409557851013,11.510005321882954,6.481066368097788e-12,0.19402373032817521,419629.6380388398,1.7790182900942006,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG470N2W-E6,LG Electronics Inc,Mono-c-Si,0,470.0,438.3,2.2,,,72.0,11.57,50.7,10.93,43.0,0.00391066,-0.1357239,45.63,1.852347422170034,11.570004455650292,1.5010525995692155e-11,0.1693443536244223,439739.7578816481,3.6859959968020033,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG475N2W-E6,LG Electronics Inc,Mono-c-Si,0,475.0,441.3,2.14,,,72.0,11.62,51.0,10.97,43.3,0.0031606399999999997,-0.130101,48.07,1.809552792260396,11.620004606934062,6.685762566620699e-12,0.1762094032580559,444451.6632654637,1.9583384315189767,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +LG Electronics Inc LG480N2W-E6,LG Electronics Inc,Mono-c-Si,0,480.0,446.1,2.14,,,72.0,11.68,51.3,11.01,43.6,0.00317696,-0.1308663,48.07,1.8198253303925207,11.680004436698042,6.681691467798302e-12,0.1719283928448968,452618.07302533,1.910461056057682,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS54-F-405-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,405.0,381.1,1.9,,,54.0,13.91,37.2,12.95,31.3,0.0061204,-0.10081200000000003,43.6,1.379897495512766,13.930300156279044,2.6413426810544368e-11,0.12117375718578113,83.03024590207988,5.606403650675454,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS54-F-410-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,410.0,385.9,1.9,,,54.0,13.98,37.3,13.05,31.4,0.0061512,-0.101083,43.6,1.382103999702485,13.99822260992998,2.5859602223652824e-11,0.1197607636332286,91.87791911429328,5.371232964169075,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS54-415-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,0,415.0,390.7,1.9,,,54.0,14.06,37.5,13.14,31.6,0.0061864,-0.10162500000000001,43.6,1.389415899016225,14.077097172731579,2.5991015306081474e-11,0.11706845561387419,96.27220339750724,5.36122500264626,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS60-450-BOB,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,0,450.0,416.6,2.16,,,120.0,13.9,41.3,12.95,34.8,6.3801000000000005,-0.10531499999999999,45.9,2.112033321435931,13.902339425337242,4.410837160813285e-08,0.03581712763763831,212.81318554857194,99.35273685006382,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS60-F-450-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,450.0,415.2,2.16,,,120.0,13.9,41.3,12.95,34.8,0.004726000000000001,-0.10531499999999999,46.0,1.6020261893134995,13.916219179693805,8.601384317351872e-11,0.11827924753515542,101.36650482931393,23.626668804235766,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS60-F-455-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,455.0,420.0,2.16,,,120.0,13.97,41.5,13.04,34.9,0.004749800000000001,-0.10582500000000002,46.0,1.6065609399090313,13.98576035955289,8.228998497394404e-11,0.12459157836869929,110.4381128970762,23.127018355083543,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS60-460-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,0,460.0,433.1,2.1,,,60.0,14.04,41.6,13.13,35.1,0.006177599999999999,-0.11273600000000002,43.6,1.5418299248309104,14.056139770130507,2.6201644907278815e-11,0.12618661831347647,109.76984882650481,5.4400017068965,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS66-F-495-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,495.0,456.8,2.37,,,132.0,13.86,45.4,12.96,38.2,0.0047124,-0.11577000000000001,46.0,1.7564500862690045,13.874269631353604,8.050767037929183e-11,0.13582932717021293,131.93014239148997,22.979963986623382,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS66-F-500-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,500.0,470.7,2.31,,,66.0,13.93,45.5,13.04,38.4,0.0061292,-0.12330500000000001,43.6,1.6857524265936015,13.945244277672824,2.576736428915629e-11,0.13840821480765295,126.47542117794514,5.360303939553002,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS66-505-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,0,505.0,475.5,2.31,,,66.0,13.99,45.7,13.12,38.5,0.0061556,-0.12384700000000001,43.6,1.690080363783982,14.004575854421665,2.4692253156402356e-11,0.1446702167378186,138.85541674181408,4.951966464290943,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS72-F-545-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,545.0,503.0,2.59,,,144.0,13.95,49.7,13.05,41.8,0.004743,-0.12673500000000001,46.0,1.921938071920836,13.964191039278319,8.013167514257811e-11,0.1494032681213024,146.86560811071115,22.867195001294238,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS72-F-550-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,550.0,507.8,2.59,,,144.0,14.0,49.8,13.12,42.0,0.004760000000000001,-0.12699,46.0,1.926832025920498,14.012234263954987,8.16843447063383e-11,0.13924526869077222,159.3421387554257,23.01401385076292,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS72-555-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,0,555.0,514.3,2.59,,,144.0,14.07,50.0,13.2,42.1,0.004924500000000001,-0.1275,45.9,1.9031726893844638,14.082851539658554,5.363584278317754e-11,0.150102253504685,164.33351822884592,18.855724564256803,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS78-600-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,0,600.0,565.1,2.72,,,78.0,14.1,54.1,13.17,45.6,0.0062039999999999994,-0.14661100000000002,43.6,2.0052937073452246,14.117455822924441,2.6339648590231498e-11,0.1673059581210685,135.14195393106667,5.453261647450736,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,645.0,607.1,3.07,,,66.0,18.35,44.8,17.11,37.7,0.006037150000000001,-0.10626559999999999,45.63,1.5597397582797858,18.380931639914532,5.964626602025733e-12,0.12380404393124277,73.44596710221357,4.729611201584365,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +LIGHT ENGINE ILUMINACAO SA HS66-F-650-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,650.0,611.9,3.07,,,66.0,18.39,45.0,17.16,37.9,0.00605031,-0.10674,45.63,1.5667854125924705,18.41971547247651,5.9914360699680385e-12,0.12202918838076476,75.52014448066754,4.74632909687752,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +LIGHT ENGINE ILUMINACAO SA HS66-F-655-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,655.0,616.7,3.07,,,66.0,18.43,45.2,17.2,38.1,0.00606347,-0.1072144,45.63,1.5742581160864066,18.45914718157518,6.061174970079553e-12,0.12022769228562041,76.0209478411952,4.826887238544515,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +LIGHT ENGINE ILUMINACAO SA HS66-F-660-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,660.0,621.5,3.07,,,66.0,18.47,45.4,17.24,38.3,0.0060766299999999995,-0.1076888,45.63,1.5817298066301893,18.498585588673485,6.131046393459368e-12,0.11843499591640694,76.52437740529321,4.906587351492028,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +LIGHT ENGINE ILUMINACAO SA HS66-F-665-MN,LIGHT ENGINE ILUMINACAO SA,Mono-c-Si,1,665.0,626.3,3.07,,,66.0,18.51,45.6,17.28,38.5,0.00608979,-0.1081632,45.63,1.5892004985307928,18.53803061370586,6.201047193270117e-12,0.11665103457705918,77.03044514465084,4.9854352954067345,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +LIGHT&HOPE ENERGY COLTD LHM72H-158M-395W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,395.0,370.3,2.016,,,48.0,10.37,48.7,9.86,40.1,0.00510204,-0.1338763,43.21,1.8084523602136935,10.370006858504615,2.0922511476310875e-11,0.3090791843551263,467331.0376360348,4.42832762354824,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-158M-400W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,400.0,375.1,2.016,,,48.0,10.45,49.0,9.92,40.3,0.0051414,-0.134701,43.21,1.8242461843287079,10.453711483976695,2.2471273720158772e-11,0.31313506377096734,881.6585301554393,4.986848244240326,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-158M-405W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,405.0,379.9,2.016,,,48.0,10.52,49.2,10.0,40.5,0.00517584,-0.1352508,43.21,1.8265978634071685,10.520006872917746,2.10935852920487e-11,0.30921294419385437,473302.54232507723,4.375700472107153,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-158M-410W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,410.0,384.7,2.016,,,48.0,10.59,49.4,10.07,40.7,0.005210279999999999,-0.1358006,43.21,1.8349668030577626,10.590006774945012,2.1530147156397733e-11,0.30430122244228214,475664.23016901256,4.4929837150654,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-158M-415W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,415.0,389.5,2.016,,,48.0,10.66,49.6,10.15,40.9,0.0052447200000000005,-0.1363504,43.21,1.846391127302603,10.661235901155958,2.293385703306013e-11,0.2987414454235513,2576.7304002944434,4.97923500121586,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-425W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,425.0,399.5,2.154,,,48.0,11.23,48.3,10.5,40.5,0.004222480000000001,-0.12475889999999998,43.12,1.7787955816884855,11.244943874267323,1.7644305660794877e-11,0.21206883484774067,159.36516725170702,9.211013786567879,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-430W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,430.0,404.3,2.154,,,48.0,11.31,48.5,10.57,40.7,0.004252560000000001,-0.12527549999999998,43.12,1.787279552356262,11.325124810738227,1.8063509009687697e-11,0.20787206702063396,155.4421490959636,9.358459288389867,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-435W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,435.0,409.1,2.154,,,48.0,11.39,48.7,10.64,40.9,0.00428264,-0.1257921,43.12,1.7957628983964764,11.405292241714534,1.848875466230324e-11,0.20373092386549432,151.74330052802267,9.504647182675678,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-440W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,440.0,413.9,2.154,,,48.0,11.46,48.9,10.71,41.1,0.004308960000000001,-0.1263087,43.12,1.803466234794547,11.474879993257755,1.870264405836288e-11,0.1999459697258311,153.99071644324923,9.55070677492441,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-445W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,445.0,418.7,2.154,,,48.0,11.53,49.1,10.78,41.3,0.00433528,-0.1268253,43.12,1.7839451134508693,11.545284498101058,1.2499766732888108e-11,0.20190259292266616,152.3070555619762,5.977693078812314,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-450W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,450.0,423.5,2.154,,,48.0,11.6,49.3,10.85,41.5,0.0043616,-0.12734189999999998,43.12,1.783385336186297,11.600005133066327,1.14496999737366e-11,0.19941530819671777,450652.9130105006,5.0678795692670695,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +LIGHT&HOPE ENERGY COLTD LHM72H-166M-455W,LIGHT&HOPE ENERGY COLTD,Mono-c-Si,0,455.0,428.4,2.154,,,48.0,11.66,49.5,10.92,41.7,0.004384160000000001,-0.12785849999999999,43.12,1.7921179507321803,11.660005033219115,1.1777919350726326e-11,0.19567616531236195,453307.86661768507,5.265436093980237,-0.3421,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW165(23)P1310x990,Lightway Green New Energy,Multi-c-Si,0,165.0,146.6,1.6193399999999998,1.644,0.985,48.0,7.9,29.0,7.2,23.0,0.00553,-0.10439999999999999,46.4,1.246587035919994,7.932287295092164,5.973404597466047e-10,0.33265276370552715,81.39291871377687,6.5127439253661965,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW170(23)P1310x990,Lightway Green New Energy,Multi-c-Si,0,170.0,151.9,1.283455,1.303,0.985,48.0,8.1,29.5,7.4,23.0,0.0056700000000000006,-0.10619999999999999,46.4,1.2530688922178297,8.135444535636072,4.659045263831247e-10,0.39434172853357236,90.11737479984433,4.1604392622149025,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW175(23)P1310x990,Lightway Green New Energy,Multi-c-Si,0,175.0,156.5,1.283455,1.303,0.985,48.0,8.2,29.5,7.6,23.0,0.0057399999999999994,-0.10619999999999999,46.4,1.2434221558008298,8.219037385896893,3.997931163509677e-10,0.38853297076522547,167.35339494909536,2.7337159323185554,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW180(23)P1310x990,Lightway Green New Energy,Multi-c-Si,0,180.0,161.1,1.283455,1.303,0.985,48.0,8.32,29.5,7.7,23.5,0.005824000000000001,-0.10619999999999999,46.4,1.260717092072716,8.33855277310758,5.591192893413934e-10,0.30544925683399127,136.97889261352066,5.454599990885027,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW185(23)P1310x990,Lightway Green New Energy,Multi-c-Si,0,185.0,165.7,1.283455,1.303,0.985,48.0,8.36,30.0,7.83,24.0,0.005852,-0.108,46.4,1.2770693003139961,8.367530475562551,5.195914795037412e-10,0.2938525280637971,326.2221761513793,4.753076156651138,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW190(23)P1310x990,Lightway Green New Energy,Multi-c-Si,0,190.0,170.3,1.283455,1.303,0.985,48.0,8.56,30.0,7.92,24.0,0.005992000000000001,-0.108,46.4,1.2855755278819774,8.57866798555467,6.124562506430033e-10,0.28660259288575113,131.41849987355656,5.9948854222291175,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW200(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,200.0,178.4,1.6193399999999998,1.644,0.985,60.0,7.6,36.0,6.9,29.0,0.00532,-0.1296,46.4,1.5659524551941904,7.628816265182263,7.510547293300653e-10,0.3513218822071023,92.65762267692165,8.87438580009994,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW205(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,205.0,183.0,1.6193399999999998,1.644,0.985,60.0,7.8,36.0,7.1,29.0,0.0054600000000000004,-0.1296,46.4,1.5635917882946675,7.827725793167038,7.468730081903048e-10,0.3426461254735296,96.39544294586028,8.587495105600452,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW210(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,210.0,187.5,1.6193399999999998,1.644,0.985,60.0,7.95,36.0,7.24,29.0,0.0055650000000000005,-0.1296,46.4,1.5631592038266793,7.977911139437873,7.568394503125667e-10,0.3362396543484794,95.77199794768754,8.534917421072894,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW215(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,215.0,192.1,1.6193399999999998,1.644,0.985,60.0,8.1,36.6,7.36,29.2,0.0056700000000000006,-0.13176000000000002,46.4,1.5817828079490208,8.133772223966725,6.910016487524385e-10,0.3813006788231359,91.45195423390996,7.573450319114127,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW220(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,220.0,196.7,1.6193399999999998,1.644,0.985,60.0,8.18,36.6,7.53,29.2,0.005726,-0.13176000000000002,46.4,1.5702122836194066,8.202748421519841,5.977599689709743e-10,0.37829842696106947,136.03060907498,6.191160034507765,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW225(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,225.0,201.3,1.6193399999999998,1.644,0.985,60.0,8.28,36.6,7.7,29.2,0.005796000000000001,-0.13176000000000002,46.4,1.5614637805231952,8.293913934518331,5.375254617344102e-10,0.3740822858967882,222.61151749121285,5.145080443578842,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW230(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,230.0,205.9,1.6193399999999998,1.644,0.985,60.0,8.38,36.6,7.87,29.2,0.005866000000000001,-0.13176000000000002,46.4,1.5532497761886357,8.385081382931348,4.862840164011425e-10,0.36979393360199464,609.848753667204,4.16218605192602,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW235(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,235.0,210.5,1.6193399999999998,1.644,0.985,60.0,8.45,37.2,8.0,29.6,0.005915,-0.13392,46.4,1.5716418991843362,8.473911663182623,4.45187220018112e-10,0.38346413278293157,999999.9780438957,3.3109283996055336,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW240(29)P1640x990,Lightway Green New Energy,Multi-c-Si,0,240.0,214.6,1.6236,1.64,0.99,60.0,8.56,37.4,8.11,29.65,0.005136000000000001,-0.13838,45.9,1.5964801036216667,8.599035846912438,5.760128611878233e-10,0.3912256364198954,999999.9219867775,2.6105302586634664,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW240(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,240.0,215.1,1.6193399999999998,1.644,0.985,60.0,8.56,37.4,8.05,29.8,0.005992000000000001,-0.13463999999999998,46.4,1.5848516770854217,8.563847405621143,4.805387790387205e-10,0.37558840821328937,835.6382777697249,3.878013468432763,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW245(29)P1640x990,Lightway Green New Energy,Multi-c-Si,0,245.0,219.1,1.6335,1.65,0.99,60.0,8.69,37.5,8.24,29.8,0.005213999999999999,-0.13874999999999998,45.9,1.6071733758316118,8.690003106000615,6.392527025118522e-10,0.3569870661066482,999999.9083406907,3.3885453079230436,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW245(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,245.0,219.1,1.6335,1.65,0.99,72.0,8.69,37.5,8.24,29.8,0.005213999999999999,-0.13874999999999998,45.9,1.6071733758316118,8.690003106000615,6.392527025118522e-10,0.3569870661066482,999999.9083406907,3.3885453079230436,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW250(29)P1640x990,Lightway Green New Energy,Multi-c-Si,0,250.0,223.8,1.6236,1.64,0.99,60.0,8.78,37.8,8.36,29.95,0.005267999999999999,-0.13986,45.9,1.6209924121564512,8.780003072612505,6.548757258696636e-10,0.3495349029394826,999999.369898261,3.5045437874608303,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW250(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,250.0,223.8,1.6335,1.65,0.99,60.0,8.78,37.8,8.36,29.95,0.005267999999999999,-0.13986,45.9,1.6209924121564512,8.780003072612505,6.548757258696636e-10,0.3495349029394826,999999.369898261,3.5045437874608303,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW255(29)P1640x990,Lightway Green New Energy,Multi-c-Si,0,255.0,228.4,1.6236,1.64,0.99,60.0,8.9,37.88,8.48,30.1,0.00534,-0.140156,45.9,1.627242084013987,8.900002953795019,6.911921196421321e-10,0.3314884730730626,999999.1902402316,3.843871880020967,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW255(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,255.0,228.4,1.6335,1.65,0.99,60.0,8.9,37.88,8.48,30.1,0.00534,-0.140156,45.9,1.627242084013987,8.900002953795019,6.911921196421321e-10,0.3314884730730626,999999.1902402316,3.843871880020967,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW260(29)P1640x990,Lightway Green New Energy,Multi-c-Si,0,260.0,233.0,1.6236,1.64,0.99,60.0,9.06,37.95,8.61,30.25,0.005436,-0.140415,45.9,1.6306547972907601,9.060002954273651,7.077046654597681e-10,0.3256744564617896,999993.980614967,3.89261359393777,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW260(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,260.0,233.0,1.6335,1.65,0.99,60.0,9.06,37.95,8.61,30.25,0.005436,-0.140415,45.9,1.6306547972907601,9.060002954273651,7.077046654597681e-10,0.3256744564617896,999993.980614967,3.89261359393777,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW265(29)P1640x990,Lightway Green New Energy,Multi-c-Si,0,265.0,237.6,1.6236,1.64,0.99,60.0,9.1,38.22,8.73,30.4,0.00546,-0.14141399999999998,45.9,1.6481576835591825,9.10000265240591,7.726010917965361e-10,0.2911343128760066,999999.9231162161,4.596683814170891,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW265(29)P1650x990,Lightway Green New Energy,Multi-c-Si,0,265.0,237.6,1.6335,1.65,0.99,60.0,9.1,38.22,8.73,30.4,0.00546,-0.14141399999999998,45.9,1.6481576835591825,9.10000265240591,7.726010917965361e-10,0.2911343128760066,999999.9231162161,4.596683814170891,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW280(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,280.0,251.0,1.9503,1.97,0.99,72.0,8.68,43.6,7.93,35.3,0.005208,-0.14388,47.2,1.833197961116541,8.708623266757364,3.8963134114232955e-10,0.3629104089838898,110.05251681683575,11.604653769237057,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW285(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,285.0,255.6,1.9503,1.97,0.99,72.0,8.83,43.6,8.03,35.5,0.005298,-0.14388,47.2,1.8441640767746388,8.8601902734618,4.5375378899083876e-10,0.3266159205477597,95.52807603111333,12.851283303597759,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW290(35)P1960x990,Lightway Green New Energy,Multi-c-Si,0,290.0,259.4,1.9404,1.96,0.99,72.0,8.49,44.81,8.11,35.81,0.0050940000000000004,-0.16579700000000003,45.9,1.9327127155341561,8.490003139240581,7.24061543438992e-10,0.3694091442082629,999996.1056174837,4.63484373978824,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW290(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,290.0,260.2,1.9503,1.97,0.99,72.0,8.6,44.96,7.97,36.4,0.00516,-0.148368,47.2,1.875544228181155,8.617336165667453,3.2537628517299295e-10,0.37948692888202284,188.25315464744284,10.022968057487596,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Lightway Green New Energy LW295(35)P1960x990,Lightway Green New Energy,Multi-c-Si,0,295.0,264.0,1.9404,1.96,0.99,72.0,8.59,44.91,8.21,35.99,0.005154,-0.166167,45.9,1.9401859875406577,8.590003005634898,7.607840626770306e-10,0.34957026746925757,999996.3621786509,4.955717320923476,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW295(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,295.0,263.9,1.9503,1.97,0.99,72.0,8.59,44.91,8.21,35.99,0.005154,-0.166167,45.9,1.9401859875406577,8.590003005634898,7.607840626770306e-10,0.34957026746925757,999996.3621786509,4.955717320923476,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW300(35)P1960x990,Lightway Green New Energy,Multi-c-Si,0,300.0,268.6,1.9404,1.96,0.99,72.0,8.68,45.08,8.31,36.15,0.005208,-0.166796,45.9,1.949776126206619,8.680003023893606,7.895273357961297e-10,0.3342641010516058,959155.6633177273,5.182899792100328,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW300(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,300.0,268.5,1.9503,1.97,0.99,72.0,8.68,45.08,8.31,36.15,0.005208,-0.166796,45.9,1.949776126206619,8.680003023893606,7.895273357961297e-10,0.3342641010516058,959155.6633177273,5.182899792100328,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW305(35)P1960x990,Lightway Green New Energy,Multi-c-Si,0,305.0,273.2,1.9404,1.96,0.99,72.0,8.76,45.31,8.42,36.34,0.005255999999999999,-0.16764700000000002,45.9,1.963732040641511,8.760002696705614,8.353070297633076e-10,0.30755628931902845,999994.8605395948,5.586296149732291,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW305(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,305.0,273.2,1.9503,1.97,0.99,72.0,8.76,45.31,8.42,36.34,0.005255999999999999,-0.16764700000000002,45.9,1.963732040641511,8.760002696705614,8.353070297633076e-10,0.30755628931902845,999994.8605395948,5.586296149732291,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW310(35)P1960x990,Lightway Green New Energy,Multi-c-Si,0,310.0,277.8,1.9404,1.96,0.99,72.0,8.85,45.56,8.51,36.54,0.00531,-0.168572,45.9,1.974956183114102,8.85000268862318,8.477345024137613e-10,0.30352140680704787,999998.8447944722,5.625249282290704,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW310(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,310.0,277.8,1.9503,1.97,0.99,72.0,8.85,45.56,8.51,36.54,0.00531,-0.168572,45.9,1.974956183114102,8.85000268862318,8.477345024137613e-10,0.30352140680704787,999998.8447944722,5.625249282290704,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW315(35)P1960x990,Lightway Green New Energy,Multi-c-Si,0,315.0,282.4,1.9404,1.96,0.99,72.0,8.92,45.79,8.57,36.81,0.005352,-0.169423,45.9,1.9863519116929356,8.920002654295642,8.687038260214137e-10,0.29728813147905714,999993.5917528024,5.76722688419681,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Lightway Green New Energy LW315(35)P1970x990,Lightway Green New Energy,Multi-c-Si,0,315.0,282.4,1.9503,1.97,0.99,72.0,8.92,45.79,8.57,36.81,0.005352,-0.169423,45.9,1.9863519116929356,8.920002654295642,8.687038260214137e-10,0.29728813147905714,999993.5917528024,5.76722688419681,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +LOF SOLAR CORP LOF-MG31-C285,LOF SOLAR CORP,Mono-c-Si,0,285.0,260.3,1.67,,,60.0,9.78,39.35,8.98,31.75,0.0068460000000000005,-0.1310355,44.96,1.64057144379244,9.809339091291458,3.6097733020882296e-10,0.3069394268688436,102.31631798968539,8.716495204095196,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C290,LOF SOLAR CORP,Mono-c-Si,0,290.0,265.0,1.67,,,60.0,9.85,39.5,9.09,31.9,0.006895000000000001,-0.131535,44.96,1.6431713430610295,9.87456904806787,3.4673483178220153e-10,0.3024798724494307,121.26749685798434,8.284118491417486,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C295,LOF SOLAR CORP,Mono-c-Si,0,295.0,269.7,1.67,,,60.0,9.91,39.65,9.2,32.05,0.006937000000000001,-0.13203450000000003,44.96,1.6449585531587871,9.928961764192794,3.2917558528012184e-10,0.2984547537331838,155.98162903398244,7.757228434829575,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C300,LOF SOLAR CORP,Mono-c-Si,0,300.0,274.4,1.67,,,60.0,9.98,39.8,9.32,32.2,0.006986000000000001,-0.13253399999999999,44.96,1.6468450530231247,9.993439307611204,3.1328972711524323e-10,0.2941755399475737,218.4541309337029,7.246093380098654,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C305,LOF SOLAR CORP,Mono-c-Si,0,305.0,279.1,1.67,,,60.0,10.04,39.95,9.43,32.35,0.0070279999999999995,-0.13303350000000003,44.96,1.6488969068301607,10.04810738818763,2.985577365895995e-10,0.2902433959589845,359.4307006714631,6.75795619079922,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG61-C305,LOF SOLAR CORP,Mono-c-Si,0,305.0,278.4,1.82,,,66.0,9.5,42.8,8.64,35.3,0.0066500000000000005,-0.142524,44.96,1.8175854239533353,9.526310204743973,5.357138901999841e-10,0.23775340650551427,85.84720252609218,12.55850971091502,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C310,LOF SOLAR CORP,Mono-c-Si,0,310.0,283.8,1.67,,,60.0,10.11,40.1,9.54,32.5,0.007077,-0.133533,44.96,1.651906830487332,10.113831606912044,2.8849589348982695e-10,0.28602614386353686,754.7030291174393,6.3867618908413215,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG61-C310,LOF SOLAR CORP,Mono-c-Si,0,310.0,283.1,1.82,,,66.0,9.57,43.0,8.73,35.5,0.006699000000000001,-0.14319,44.96,1.82396816983025,9.594259654254694,5.270167822542791e-10,0.23304173069117864,91.93080228610876,12.332499307032744,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C315,LOF SOLAR CORP,Mono-c-Si,0,315.0,288.6,1.67,,,60.0,10.18,40.25,9.65,32.65,0.007126,-0.13403250000000003,44.96,1.6552708134540361,10.18370666230214,2.802111662536672e-10,0.2817619852315775,999999.9302766708,6.059972873481698,-0.427,N,2025.7.3,6/23/2025,2.0,first_pass +LOF SOLAR CORP LOF-MG61-C315,LOF SOLAR CORP,Mono-c-Si,0,315.0,287.8,1.82,,,66.0,9.64,43.2,8.82,35.7,0.006748000000000001,-0.143856,44.96,1.8303918167580036,9.662274770957477,5.187703570386617e-10,0.22840947337684891,98.85028434335815,12.112940177100043,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C320,LOF SOLAR CORP,Mono-c-Si,0,320.0,293.3,1.67,,,60.0,10.25,40.4,9.76,32.8,0.007175000000000001,-0.13453199999999998,44.96,1.6659697194216658,10.250002662726079,3.0131447856378286e-10,0.2596620441553887,999999.7665506903,6.628490871730022,-0.427,N,2025.7.3,6/23/2025,2.0,first_pass +LOF SOLAR CORP LOF-MG61-C320,LOF SOLAR CORP,Mono-c-Si,0,320.0,292.5,1.82,,,66.0,9.71,43.4,8.91,35.9,0.006797000000000001,-0.144522,44.96,1.836854770443288,9.73035409688358,5.109457710779287e-10,0.22385489875764478,106.79084426945569,11.899575407052517,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C325,LOF SOLAR CORP,Mono-c-Si,0,325.0,298.0,1.67,,,60.0,10.32,40.55,9.86,32.95,0.007224,-0.1350315,44.96,1.6755365181464923,10.320002500446252,3.1858771476106933e-10,0.2421847509839104,999999.1293406003,7.05149669012271,-0.427,N,2025.7.3,6/23/2025,2.0,first_pass +LOF SOLAR CORP LOF-MG61-C325,LOF SOLAR CORP,Mono-c-Si,0,325.0,297.2,1.82,,,66.0,9.78,43.6,9.0,36.1,0.0068460000000000005,-0.145188,44.96,1.8433555187304425,9.79849621279229,5.035164849049682e-10,0.21937630530765917,115.99673914537723,11.692161255938737,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG31-C330,LOF SOLAR CORP,Mono-c-Si,0,330.0,302.7,1.67,,,60.0,10.39,40.7,9.97,33.1,0.007273000000000001,-0.135531,44.96,1.6863337755062606,10.390178765402208,3.4253558387277e-10,0.2186247865629152,12706.729273336157,7.623150531212584,-0.427,N,2025.7.3,6/23/2025,2.0,first_pass +LOF SOLAR CORP LOF-MG61-C330,LOF SOLAR CORP,Mono-c-Si,0,330.0,301.9,1.82,,,66.0,9.85,43.8,9.09,36.3,0.006895000000000001,-0.145854,44.96,1.8498926251698817,9.866699737329007,4.964580412982103e-10,0.21497202675247135,126.79688046846712,11.490466601244183,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C330,LOF SOLAR CORP,Mono-c-Si,0,330.0,303.9,1.8,,,60.0,10.47,39.5,9.88,33.4,0.007014900000000002,-0.127585,45.01,1.6101766615630877,10.47380572549435,2.297350283624459e-10,0.11986584429197726,329.76510812619813,7.460899137096839,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C335,LOF SOLAR CORP,Mono-c-Si,0,335.0,308.7,1.8,,,60.0,10.56,39.65,9.99,33.55,0.007075200000000001,-0.1280695,45.01,1.6147271988299774,10.562787690330161,2.269278609975046e-10,0.11714839890360802,443.76780124718965,7.270650571089298,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG61-C340,LOF SOLAR CORP,Mono-c-Si,0,340.0,311.4,1.82,,,66.0,10.0,44.2,9.26,36.7,0.007000000000000001,-0.14718600000000004,44.96,1.8652385198166728,10.014448990608745,4.961396604020756e-10,0.2057130876457659,142.37195340771171,11.336903548765578,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C340,LOF SOLAR CORP,Mono-c-Si,0,340.0,313.4,1.8,,,60.0,10.65,39.8,10.09,33.7,0.007135500000000001,-0.128554,45.01,1.6201705042566903,10.652194133425287,2.2694587285792148e-10,0.11426040602102853,554.6032210145363,7.192413408530872,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG61-C345,LOF SOLAR CORP,Mono-c-Si,0,345.0,316.1,1.82,,,66.0,10.07,44.4,9.35,36.9,0.0070490000000000014,-0.147852,44.96,1.8718559240479637,10.082809150607925,4.897482375024229e-10,0.20153262380081186,158.43624106279316,11.147865056915366,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C345,LOF SOLAR CORP,Mono-c-Si,0,345.0,315.3,1.98,,,72.0,9.62,47.2,8.98,38.4,0.006734,-0.157176,44.96,1.9597752672814273,9.632669482642601,3.2775696864580345e-10,0.3339197588643731,253.54692972131005,7.962812188669457,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C345,LOF SOLAR CORP,Mono-c-Si,0,345.0,318.1,1.8,,,60.0,10.74,39.95,10.19,33.85,0.007195800000000001,-0.1290385,45.01,1.6256291562243945,10.741623942691723,2.2700839959821414e-10,0.11142358032285281,736.9037348104273,7.11662619593478,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG61-C350,LOF SOLAR CORP,Mono-c-Si,0,350.0,320.8,1.82,,,66.0,10.13,44.6,9.43,37.1,0.007091000000000002,-0.148518,44.96,1.8785815602544713,10.141254453793637,4.83609593238637e-10,0.19759837329659494,177.85596012232998,10.971973968981946,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C350,LOF SOLAR CORP,Mono-c-Si,0,350.0,320.0,1.98,,,72.0,9.7,47.4,9.07,38.6,0.00679,-0.157842,44.96,1.967398581305412,9.71127447762935,3.2836541957537525e-10,0.3278996300492054,282.1085658563217,7.901229113197153,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C350,LOF SOLAR CORP,Mono-c-Si,0,350.0,322.9,1.8,,,60.0,10.83,40.1,10.29,34.0,0.007256100000000001,-0.129523,45.01,1.6311025404214012,10.831076730877136,2.2711324014913995e-10,0.10863663794217435,1092.6918473681385,7.043186600104115,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C355,LOF SOLAR CORP,Mono-c-Si,0,355.0,324.7,1.98,,,72.0,9.78,47.6,9.15,38.8,0.0068460000000000005,-0.158508,44.96,1.976190756077355,9.79080373999095,3.332505769766167e-10,0.3218706136565715,291.3708562900054,7.956891089381234,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C355,LOF SOLAR CORP,Mono-c-Si,0,355.0,327.6,1.8,,,60.0,10.92,40.25,10.4,34.15,0.007316400000000001,-0.1300075,45.01,1.6357541098425543,10.920186145734025,2.24674797616756e-10,0.10610861716688885,6224.733254891686,6.869502688549316,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C360,LOF SOLAR CORP,Mono-c-Si,0,360.0,329.4,1.98,,,72.0,9.85,47.8,9.23,39.0,0.006895000000000001,-0.159174,44.96,1.983912086631041,9.85951941033695,3.3386241837559414e-10,0.316382954425492,327.37033104208507,7.905517407948534,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C360,LOF SOLAR CORP,Mono-c-Si,0,360.0,332.4,1.8,,,60.0,11.01,40.4,10.5,34.3,0.007376700000000001,-0.130492,45.01,1.6425437882894158,11.010001881951666,2.2902322801977606e-10,0.10317000939444403,603649.7282781051,6.96235934828746,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C360,LOF SOLAR CORP,Mono-c-Si,0,360.0,331.5,1.98,,,66.0,10.36,43.4,9.81,36.7,0.006941200000000001,-0.140182,45.01,1.7659403976350045,10.362402056517631,2.182787468839381e-10,0.13366694112398905,576.5016963879892,7.095885897840433,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C365,LOF SOLAR CORP,Mono-c-Si,0,365.0,334.1,1.98,,,72.0,9.93,48.0,9.31,39.2,0.006951000000000001,-0.15984,44.96,1.9927143294287817,9.93908475835546,3.3880302857569984e-10,0.31055396497330673,339.44780648327446,7.961653864894275,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C365,LOF SOLAR CORP,Mono-c-Si,0,365.0,337.1,1.8,,,60.0,11.1,40.55,10.6,34.45,0.007437000000000001,-0.1309765,45.01,1.6500718170924655,11.100001851501975,2.358680072291025e-10,0.10014483469599465,600455.1139443174,7.146714873948293,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C365,LOF SOLAR CORP,Mono-c-Si,0,365.0,336.2,1.98,,,66.0,10.45,43.55,9.91,36.85,0.0070015,-0.1406665,45.01,1.7712468208896512,10.451805981669478,2.1812478583631722e-10,0.13061310114383906,755.770183813955,7.009479354456593,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C370,LOF SOLAR CORP,Mono-c-Si,0,370.0,338.8,1.98,,,72.0,10.0,48.2,9.39,39.4,0.007000000000000001,-0.160506,44.96,2.0004549669177667,10.00786124217273,3.394722343314816e-10,0.30525019424923433,388.29770313006253,7.912517225821226,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C370,LOF SOLAR CORP,Mono-c-Si,0,370.0,341.9,1.8,,,60.0,11.19,40.7,10.69,34.6,0.0074973,-0.13146100000000002,45.01,1.6569476196617487,11.190001828986325,2.4051847983518753e-10,0.0972446580920268,595029.381954688,7.245906684847924,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C370,LOF SOLAR CORP,Mono-c-Si,0,370.0,341.0,1.98,,,66.0,10.54,43.7,10.0,37.0,0.0070618,-0.14115100000000003,45.01,1.7775189252426924,10.541621604239246,2.2063351211006238e-10,0.12737346825617807,827.8940872291355,7.032650612053142,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C375,LOF SOLAR CORP,Mono-c-Si,0,375.0,343.6,1.98,,,72.0,10.08,48.4,9.47,39.6,0.007056000000000001,-0.161172,44.96,2.009266621521845,10.087461129122218,3.4446721415907785e-10,0.29961142951981057,404.77568792469987,7.969047042021652,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C375,LOF SOLAR CORP,Mono-c-Si,0,375.0,346.7,1.8,,,60.0,11.28,40.85,10.79,34.75,0.0075576,-0.13194550000000002,45.01,1.6644631991437182,11.2800017970246,2.4754671574702116e-10,0.09432739863917729,592170.1148739746,7.426277520964304,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C375,LOF SOLAR CORP,Mono-c-Si,0,375.0,345.7,1.98,,,66.0,10.63,43.85,10.1,37.15,0.007122100000000001,-0.1416355,45.01,1.782853125236732,10.631061229779986,2.2053982285338198e-10,0.12442928804344411,1246.3687498754407,6.9501280508467245,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C380,LOF SOLAR CORP,Mono-c-Si,0,380.0,348.3,1.98,,,72.0,10.14,48.6,9.55,39.8,0.007098000000000001,-0.161838,44.96,2.0159719930855764,10.145520359869366,3.4093534846499875e-10,0.2948976672329294,541.6789821925875,7.8188218578292625,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH62-C380,LOF SOLAR CORP,Mono-c-Si,0,380.0,351.4,1.8,,,60.0,11.37,41.0,10.89,34.9,0.0076179,-0.13243000000000002,45.01,1.6719714885167867,11.370001764480762,2.546892576623432e-10,0.0914635118985133,589447.9863067864,7.604401286113286,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C380,LOF SOLAR CORP,Mono-c-Si,0,380.0,350.4,1.98,,,66.0,10.72,44.0,10.19,37.3,0.0071824,-0.14212,45.01,1.7891381001389874,10.720897762434019,2.2308017270266133e-10,0.12130026323622708,1448.421974666837,6.974763331855868,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C385,LOF SOLAR CORP,Mono-c-Si,0,385.0,353.0,1.98,,,72.0,10.2,48.8,9.63,40.0,0.0071400000000000005,-0.162504,44.96,2.022701248408203,10.203636916035954,3.375520566413323e-10,0.290253750592442,814.0383609490674,7.67206957802533,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C385,LOF SOLAR CORP,Mono-c-Si,0,385.0,355.2,1.98,,,66.0,10.81,44.15,10.29,37.45,0.0072427,-0.1426045,45.01,1.7944988771710872,10.810372121483807,2.230443881583433e-10,0.1184600500707707,3441.2263717548117,6.89592469051932,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C390,LOF SOLAR CORP,Mono-c-Si,0,390.0,357.7,1.98,,,72.0,10.27,49.0,9.7,40.2,0.007189000000000001,-0.16317,44.96,2.0315956288624073,10.273357066718875,3.4244779732923156e-10,0.2851418578867832,872.3114814885623,7.7368433964576395,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C390,LOF SOLAR CORP,Mono-c-Si,0,390.0,359.9,1.98,,,66.0,10.9,44.3,10.39,37.6,0.0073030000000000005,-0.143089,45.01,1.800488434864766,10.900002113098957,2.2482957028745887e-10,0.11554992683090008,596105.5148980687,6.889430875164415,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C395,LOF SOLAR CORP,Mono-c-Si,0,395.0,362.5,1.98,,,72.0,10.34,49.2,9.78,40.4,0.007238000000000001,-0.16383600000000004,44.96,2.039391173157672,10.342303963682237,3.4330771119239363e-10,0.2802403089334008,1257.6961053612788,7.6947141347406705,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C395,LOF SOLAR CORP,Mono-c-Si,0,395.0,364.7,1.98,,,66.0,10.99,44.45,10.46,37.78,0.007363300000000001,-0.14357350000000002,45.01,1.8088043588399807,10.990454372447791,2.3328652184979876e-10,0.10890128261911765,2634.019025864718,7.142535860401287,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MG81-C400,LOF SOLAR CORP,Mono-c-Si,0,400.0,367.2,1.98,,,72.0,10.41,49.4,9.85,40.6,0.007287000000000001,-0.164502,44.96,2.048290122023087,10.412052304361087,3.4824429126525915e-10,0.27527689061482696,1396.2987652330037,7.759287872222734,-0.427,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C400,LOF SOLAR CORP,Mono-c-Si,0,400.0,369.4,1.98,,,66.0,11.08,44.6,10.56,37.9,0.007423600000000001,-0.14405800000000002,45.01,1.8135951705662523,11.080002078527288,2.3139329412171153e-10,0.10950223206547827,583785.1436663005,6.996579536227456,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C400,LOF SOLAR CORP,Mono-c-Si,0,400.0,368.6,2.15,,,72.0,10.28,48.24,9.85,40.73,0.006887600000000001,-0.15581520000000001,45.01,1.9606429758436072,10.280001342775767,2.1209690898539451e-10,0.13059986981556315,999999.6911677907,6.891697553951719,-0.397,N,2025.7.3,6/23/2025,2.0,first_pass +LOF SOLAR CORP LOF-MH82-C405,LOF SOLAR CORP,Mono-c-Si,0,405.0,374.2,1.98,,,66.0,11.17,44.75,10.65,38.05,0.007483900000000001,-0.14454250000000002,45.01,1.8205041416587409,11.17000205487461,2.3583747307441903e-10,0.10651344769319784,579052.9302416274,7.0911725054863135,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C405,LOF SOLAR CORP,Mono-c-Si,0,405.0,373.3,2.15,,,72.0,10.32,48.29,9.89,40.98,0.0069144,-0.1559767,45.01,1.9668881370096685,10.320002167774755,2.244437712763233e-10,0.1332527302633785,634435.051553929,7.347936332664551,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C410,LOF SOLAR CORP,Mono-c-Si,0,410.0,379.0,1.98,,,66.0,11.26,44.9,10.74,38.2,0.007544200000000001,-0.14502700000000002,45.01,1.8275661633553963,11.260033900858478,2.40800990430933e-10,0.1035455279062047,34392.344496553524,7.202389229262668,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C410,LOF SOLAR CORP,Mono-c-Si,0,410.0,378.0,2.15,,,72.0,10.45,48.32,10.01,41.0,0.0070015,-0.1560736,45.01,1.9676109976880956,10.450002216186451,2.2586019504881937e-10,0.1323519961444998,624145.1828398407,7.29392202774569,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C415,LOF SOLAR CORP,Mono-c-Si,0,415.0,383.7,1.98,,,66.0,11.35,45.05,10.83,38.35,0.007604500000000001,-0.1455115,45.01,1.8343138663392256,11.350002003877755,2.448486251012361e-10,0.1006850945333184,570342.4504349895,7.277516918078993,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C415,LOF SOLAR CORP,Mono-c-Si,0,415.0,382.8,2.15,,,72.0,10.64,48.35,10.17,41.01,0.007128800000000001,-0.15617050000000002,45.01,1.9667120444740893,10.640002312839023,2.2395739130315492e-10,0.13203833307813917,607491.3682760664,7.064555054889162,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH82-C420,LOF SOLAR CORP,Mono-c-Si,0,420.0,388.5,1.98,,,66.0,11.44,45.2,10.91,38.5,0.0076648,-0.14599600000000001,45.01,1.8405139827320676,11.440001983425638,2.470950255482532e-10,0.09790927675246926,564779.9558529527,7.2882218068670666,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C420,LOF SOLAR CORP,Mono-c-Si,0,420.0,387.5,2.15,,,72.0,10.81,48.39,10.29,41.02,0.0072427,-0.1562997,45.01,1.9661361358736926,10.810360496591505,2.211138282053698e-10,0.1328321938070079,3983.1637690768607,6.820647262604228,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C425,LOF SOLAR CORP,Mono-c-Si,0,425.0,392.3,2.15,,,72.0,10.84,48.45,10.35,41.1,0.0072628,-0.1564935,45.01,1.970013400661463,10.840002365375934,2.2599558419354329e-10,0.12940131037144217,593076.6976818489,6.981841582563209,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C430,LOF SOLAR CORP,Mono-c-Si,0,430.0,397.0,2.15,,,72.0,10.91,48.6,10.43,41.25,0.007309700000000001,-0.156978,45.01,1.9776663451362142,10.910002334248746,2.3189282358593514e-10,0.1263276157044065,590499.2991771501,7.149042421562891,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C435,LOF SOLAR CORP,Mono-c-Si,0,435.0,401.8,2.15,,,72.0,11.0,48.75,10.51,41.4,0.007370000000000001,-0.1574625,45.01,1.9838097434491655,11.000002322742553,2.3392016906043355e-10,0.12324753185719457,583730.9626125902,7.153278444462784,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C440,LOF SOLAR CORP,Mono-c-Si,0,440.0,406.5,2.15,,,72.0,11.09,48.9,10.59,41.55,0.0074303,-0.157947,45.01,1.9899576501953504,11.09000230917493,2.3596186745428496e-10,0.12021442543477918,577395.8297473878,7.157970659707489,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C445,LOF SOLAR CORP,Mono-c-Si,0,445.0,411.3,2.15,,,72.0,11.18,49.05,10.67,41.7,0.0074906,-0.1584315,45.01,1.996109947276719,11.180002293580245,2.3801778032560797e-10,0.11722723307034273,571476.284880826,7.163102291317568,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C450,LOF SOLAR CORP,Mono-c-Si,0,450.0,416.1,2.15,,,72.0,11.27,49.2,10.76,41.85,0.0075509,-0.15891600000000003,45.01,2.0030403159809,11.270002268797843,2.423776570091941e-10,0.11420517251720487,567356.0774025631,7.250907493295858,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C455,LOF SOLAR CORP,Mono-c-Si,0,455.0,420.8,2.15,,,72.0,11.36,49.35,10.84,42.0,0.0076112,-0.15940050000000003,45.01,2.006211770676902,11.360002262327141,2.356888323144782e-10,0.11190608533741234,561974.551722659,6.9398442714079325,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LOF SOLAR CORP LOF-MH92-C460,LOF SOLAR CORP,Mono-c-Si,0,460.0,425.6,2.15,,,72.0,11.45,49.5,10.92,42.15,0.0076714999999999995,-0.159885,45.01,2.007611503683202,11.450002261881373,2.2426727319040993e-10,0.10999501834093184,556860.2985025506,6.443501418724733,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60-270M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,270.0,248.7,1.58,,,60.0,9.2,38.1,8.68,31.1,0.0,-0.1143,44.37,1.4217018457823896,9.208223049301246,2.0907545800258714e-11,0.30648625343998,342.89878033168395,-2.7515327400854654,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60-275M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,275.0,253.5,1.58,,,60.0,9.32,38.3,8.79,31.3,0.0,-0.1149,44.37,1.4302697817598777,9.328588442601916,2.1611345370258642e-11,0.2992959726401596,324.78979349203155,-2.592161619452005,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60-280M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,280.0,258.2,1.58,,,60.0,9.45,38.5,8.92,31.4,0.0,-0.11549999999999999,44.37,1.435694316176085,9.458071176348161,2.1118085619531105e-11,0.3049471618768937,357.04222091090264,-2.8848064070206343,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-280M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,280.0,254.2,1.635,1.65,0.991,60.0,9.34,39.3,8.75,32.0,0.0033623999999999998,-0.11161199999999998,48.2,1.5094848832339967,9.353341868712194,4.5238974010687754e-11,0.31200706079816687,218.42112111469075,8.709190757148424,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-280M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,280.0,258.2,1.635,1.65,0.991,60.0,9.34,39.3,8.75,32.0,0.0034557999999999998,-0.110433,45.2,1.4902775500045082,9.354035158644606,3.2322633313373594e-11,0.3167283181047376,210.7737034783977,6.929994430528453,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60-285M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,285.0,262.9,1.58,,,60.0,9.59,38.6,9.05,31.5,0.0,-0.1158,44.37,1.440014704821616,9.5983811049363,2.1660851363697376e-11,0.2989210521939687,342.03759044860425,-2.8003666975865844,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-285M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,285.0,258.9,1.635,1.65,0.991,60.0,9.46,39.5,8.88,32.1,0.0034056000000000004,-0.11218,48.2,1.51411076926535,9.4719450115273,4.358585182331125e-11,0.31788932636021794,251.75639970287617,8.263281227516543,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-285M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,285.0,263.0,1.635,1.65,0.991,60.0,9.46,39.5,8.88,32.1,0.0035002000000000006,-0.11099500000000001,45.2,1.4948748404390002,9.47263417119443,3.113691837014968e-11,0.32253933383442673,241.50552792289105,6.489382263021867,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60-290M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,290.0,267.7,1.58,,,60.0,9.71,38.8,9.15,31.7,0.0,-0.11639999999999998,44.37,1.4493368925259296,9.719722881711954,2.2658523377910998e-11,0.2921013027765591,291.71430591718376,-2.5390929764370775,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60BP-290M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,290.0,267.9,1.605,,,60.0,9.36,39.2,8.9,32.6,0.0037440000000000004,-0.104272,46.57,1.449673043292255,9.362634289293409,1.681363483534796e-11,0.23732164045543055,843.2371538062791,7.074104826542422,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-290M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,290.0,263.6,1.635,1.65,0.991,60.0,9.58,39.7,8.98,32.3,0.0034487999999999997,-0.112748,48.2,1.5237707696482095,9.593261337103533,4.558963146729344e-11,0.3106274923796895,224.39754119608742,8.552043034785317,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-290M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,290.0,267.7,1.635,1.65,0.991,60.0,9.58,39.7,8.98,32.3,0.0035445999999999997,-0.11155700000000002,45.2,1.5043922795965472,9.593970095148281,3.257145853215406e-11,0.3152653883510673,216.19340697614774,6.7747114409302664,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60-295M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,295.0,272.4,1.58,,,60.0,9.85,38.9,9.28,31.8,0.0,-0.1167,44.37,1.453643988141841,9.860010602516859,2.3221421363485296e-11,0.2864106669120242,281.815711214626,-2.4580052541247723,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60BP-295M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,295.0,272.7,1.605,,,60.0,9.47,39.4,9.01,32.7,0.003788,-0.10480400000000001,46.57,1.4551752874705086,9.472237608898594,1.6437718552763753e-11,0.2442634479331356,1033.7708790991467,6.773645577452285,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIB-295M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,295.0,274.1,1.62,,,60.0,9.59,39.6,9.03,32.7,0.0042196,-0.10652400000000001,46.2,1.4429344057367255,9.600729967241804,1.1375333338116532e-11,0.26849164731512337,239.9666965728069,2.35660243603107,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPB-295M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,295.0,275.0,1.623,,,60.0,9.59,39.6,9.03,32.7,0.0044114,-0.105732,44.63,1.465236369320644,9.600036432955529,1.7285770942805573e-11,0.26304036938276826,251.3400082712239,6.660468127334706,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-295M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,295.0,268.3,1.635,1.65,0.991,60.0,9.69,39.9,9.05,32.6,0.0034883999999999996,-0.113316,48.2,1.5376891877900896,9.706034671264815,5.10130943963153e-11,0.2909249947932414,175.81047934626267,9.45549503916275,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-295M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,295.0,273.4,1.583,1.65,0.991,60.0,9.92,39.7,9.21,32.0,0.003968,-0.10639600000000002,45.95,1.4619908558610022,9.9478777135183,1.5506387566401034e-11,0.3520446159606172,125.27148659129847,5.168473350400382,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60BP-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,300.0,277.4,1.605,,,60.0,9.58,39.6,9.11,32.9,0.003832,-0.10533600000000001,46.57,1.4636748596657596,9.582629344883882,1.6962659061497e-11,0.23836165153595415,868.4690588789286,6.948458437218821,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HBD-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,300.0,281.1,1.64,,,60.0,9.44,40.3,9.01,33.3,0.0035872,-0.105989,43.93,1.4461847472753748,9.440007406807895,7.459885184163279e-12,0.27855249624157924,355014.06861024594,1.3241465897088038,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIB-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,300.0,278.9,1.62,,,60.0,9.7,39.8,9.13,32.9,0.004267999999999999,-0.10706199999999999,46.2,1.4512712687554878,9.711029130958988,1.1729785420598495e-11,0.262382646334608,230.76266708633804,2.519189811184937,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIBD-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,300.0,283.4,1.64,,,60.0,9.44,40.25,9.01,33.29,0.0038704,-0.10746750000000001,41.49,1.458329217664974,9.440327534747535,9.731692704897713e-12,0.27098756607517427,7810.2333790277235,1.9420326044603073,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,300.0,282.1,1.62,,,60.0,9.7,39.8,9.13,32.9,0.005528999999999999,-0.106664,43.68,1.4495710177359302,9.711083039446972,1.1357863925789973e-11,0.26279532325585714,230.00140529441967,2.4564889358345137,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPB-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,300.0,279.7,1.623,,,60.0,9.7,39.8,9.13,32.9,0.004462,-0.106266,44.63,1.4737098991979802,9.710329472896696,1.78215235451622e-11,0.2569532874605551,241.2946683751394,6.828032537231222,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPH-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,300.0,278.0,1.623,,,60.0,9.7,39.8,9.13,32.9,0.003977,-0.10467399999999999,46.48,1.460129906938754,9.710750297183104,1.3857092382930826e-11,0.2602354373637717,234.81059222179,6.341579822195812,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,300.0,272.9,1.635,1.65,0.991,60.0,9.81,40.1,9.15,32.8,0.0035315999999999998,-0.113884,48.2,1.5473471012411215,9.82715261716305,5.327209344316843e-11,0.2840947467854717,162.48071029275835,9.735227111874273,-0.391,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-300M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,300.0,278.2,1.583,1.65,0.991,60.0,9.96,39.9,9.28,32.3,0.0039840000000000006,-0.10693200000000001,45.95,1.470133938296981,9.98317963885421,1.5853220028204044e-11,0.33491160569582806,143.90731596440287,5.310148311104661,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60BP-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,305.0,282.2,1.605,,,60.0,9.69,39.8,9.22,33.1,0.003876,-0.10586799999999999,46.57,1.4714136597932834,9.692269923847288,1.7277224132542614e-11,0.23267236687534412,993.247107759049,7.00650518518683,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HBD-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,305.0,285.9,1.64,,,60.0,9.55,40.5,9.12,33.5,0.0036290000000000003,-0.10651500000000001,43.93,1.4546104221338965,9.550187944732727,7.727372185387204e-12,0.2721702759765943,13829.73587572279,1.5205545670458243,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIB-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,305.0,283.6,1.62,,,60.0,9.78,40.1,9.21,33.1,0.0043032,-0.107869,46.2,1.4607829946830355,9.790893592985773,1.1522333116328455e-11,0.26821239288351867,240.79449450375282,2.2995629240370565,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIBD-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,305.0,288.2,1.64,,,60.0,9.55,40.46,9.12,33.46,0.003915500000000001,-0.1080282,41.49,1.4656452398980802,9.550003194084628,9.795944053813848e-12,0.26971146199282314,806422.703115037,1.8986662526997569,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,305.0,286.9,1.62,,,60.0,9.78,40.06,9.205,33.135,0.0055746,-0.1073608,43.68,1.4595123387379931,9.791123702803684,1.1552495952377349e-11,0.2598399657484984,228.4522448251766,2.530191152655016,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPB-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,305.0,284.5,1.623,,,60.0,9.78,40.1,9.21,33.1,0.0044988,-0.10706700000000001,44.63,1.4833580872085694,9.790185237142083,1.7510142157134988e-11,0.2628039082889711,252.34780572948296,6.601682529610931,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPH-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,305.0,282.8,1.623,,,60.0,9.78,40.1,9.21,33.1,0.0040098,-0.10546300000000002,46.48,1.4697029056788358,9.790611072827042,1.3615059922006044e-11,0.2660716646129697,245.23259184468998,6.116077792519489,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,305.0,278.9,1.58,,,60.0,9.94,40.2,9.24,33.0,0.0041748,-0.11215800000000002,48.75,1.525135194196247,9.96064124002585,3.447441470510852e-11,0.2734669653900962,131.69081193842513,7.6921850882543605,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-305M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,305.0,282.9,1.583,1.956,0.991,60.0,9.99,40.2,9.33,32.7,0.003996,-0.10773600000000001,45.95,1.4831889818554445,10.009881679421063,1.6531790665828623e-11,0.3168641777029486,159.21558173505673,5.634931164589459,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60BP-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,310.0,286.9,1.605,,,60.0,10.05,40.2,9.44,32.9,0.00402,-0.10693200000000001,46.57,1.4832488544668128,10.063619755052686,1.6751273229194088e-11,0.2905640051960465,214.40681297532666,6.474109349748725,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HBD-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,310.0,290.7,1.64,,,60.0,9.66,40.7,9.23,33.6,0.0036708,-0.10704100000000001,43.93,1.460621367928211,9.660003373057839,7.645801149447709e-12,0.27840555436121805,797326.972076408,1.3371591920291535,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIB-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,310.0,288.4,1.62,,,60.0,9.86,40.3,9.3,33.3,0.004338399999999999,-0.108407,46.2,1.4677443862095043,9.869627145454144,1.1566554913575465e-11,0.26311246441262276,269.4764355820792,2.2574814470186464,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIBD-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,310.0,293.0,1.64,,,60.0,9.66,40.67,9.23,33.63,0.003960600000000001,-0.1085889,41.49,1.4735042087396168,9.660003271079578,9.955632858429534e-12,0.2683470418851123,792481.5937401793,1.9377748525213832,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,310.0,291.7,1.62,,,60.0,9.86,40.34,9.299,33.34,0.0056202,-0.10811120000000002,43.68,1.4677105635602898,9.869743648041204,1.1246203245741458e-11,0.26291998892542,266.05959896747856,2.2295256695625416,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPB-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,310.0,289.3,1.623,,,60.0,9.86,40.3,9.3,33.3,0.0045356,-0.107601,44.63,1.4904239967166681,9.868945812604066,1.757801760136686e-11,0.2577292311791353,284.0670103733,6.558373215985558,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPH-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,310.0,287.5,1.623,,,60.0,9.86,40.3,9.3,33.3,0.0040425999999999995,-0.105989,46.48,1.4767053875530438,9.869355311751953,1.3667466862197854e-11,0.2609817806085913,275.06088976439366,6.072534035975263,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,310.0,283.6,1.58,,,60.0,9.98,40.3,9.35,33.2,0.0041916,-0.112437,48.75,1.5258301402749765,9.993650490012584,3.3101612301726905e-11,0.2588704333715345,189.26257961877317,7.273705423219434,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-310M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,310.0,287.7,1.583,,,60.0,10.02,40.5,9.36,33.1,0.004008,-0.10854000000000001,45.95,1.4977441636245954,10.038827604536039,1.7657072890490328e-11,0.29901206334864444,159.13340617100022,6.1753379862356645,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60BP-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,315.0,291.7,1.605,,,60.0,10.14,40.4,9.52,33.1,0.004056000000000001,-0.107464,46.57,1.4918028240259547,10.15403332253035,1.725420994056376e-11,0.2850096205034928,205.93822766028563,6.655058682181582,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HBD-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,315.0,295.5,1.64,,,60.0,9.75,40.9,9.32,33.8,0.003705,-0.107567,43.93,1.468686798023925,9.75000339919554,7.848139890572667e-12,0.2728198819373525,782545.5304861655,1.4763419867411596,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIB-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,315.0,293.2,1.62,,,60.0,9.94,40.6,9.36,33.7,0.0043736,-0.10921400000000002,46.2,1.4832241216493565,9.95044820921448,1.265582048554591e-11,0.24418921711629335,232.31166031050944,2.949287578663315,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIBD-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,315.0,297.8,1.64,,,60.0,9.75,40.91,9.32,33.83,0.0039975,-0.1092297,41.49,1.482485772651008,9.750003336866756,1.0102069370291854e-11,0.26714604692236454,780586.0874907982,1.9819611434842608,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,315.0,296.5,1.62,,,60.0,9.94,40.63,9.357,33.666,0.0056658,-0.10888840000000002,43.68,1.4815035549446602,9.950963251604655,1.2010922408668039e-11,0.2519909288480557,228.4714365518212,2.7200465992128917,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPB-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,315.0,294.1,1.623,,,60.0,9.94,40.6,9.36,33.7,0.0045724,-0.10840200000000001,44.63,1.5061766515164419,9.949769434096797,1.922018341055283e-11,0.23875599813468992,242.92447401437218,7.271331684606953,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPH-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,315.0,292.3,1.623,,,60.0,9.94,40.6,9.36,33.7,0.0040754,-0.10677800000000001,46.48,1.4922696688437145,9.950178049125002,1.4944159529351146e-11,0.24204426907869617,236.38322239044936,6.782892123267612,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,315.0,288.4,1.58,,,60.0,10.1,40.5,9.43,33.4,0.004242,-0.11299500000000001,48.75,1.5368819693650824,10.116316653094328,3.5416125682032715e-11,0.25250616410675447,156.30118911609287,7.771420314125466,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-315M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,315.0,292.5,1.583,,,60.0,10.05,40.8,9.41,33.5,0.00402,-0.109344,45.95,1.510728392615399,10.06593251484931,1.8361115249553508e-11,0.2813643346796023,177.48055518809323,6.4782999542755695,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HBD-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,320.0,300.3,1.64,,,60.0,9.86,41.1,9.42,34.0,0.0037468,-0.10809300000000001,43.93,1.4761712716350792,9.860003455733757,7.982123388514428e-12,0.26703418595725387,761918.4151972008,1.5235483613744374,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIB-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,298.0,1.62,,,60.0,10.02,40.9,9.43,33.9,0.0044088,-0.110021,46.2,1.4934969391480843,10.0311420052851,1.2591453655863411e-11,0.24996261773990394,224.79126315011354,2.8414546788404973,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIBD-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,320.0,302.7,1.64,,,60.0,9.86,41.13,9.42,34.01,0.0040425999999999995,-0.10981710000000001,41.49,1.4900934628151363,9.860003436560072,1.0147290482122318e-11,0.2659506974208154,763062.7936080693,1.9259665941086725,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,301.3,1.62,,,60.0,10.02,40.93,9.432,33.928,0.0057114,-0.10969240000000001,43.68,1.4927656796425595,10.031024199633377,1.2178748445857084e-11,0.25018797074603566,227.3982036764146,2.769391119716577,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPB-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,298.9,1.623,,,60.0,10.02,40.9,9.43,33.9,0.0046092,-0.109203,44.63,1.5166037683490192,10.030437720155392,1.9124525937401637e-11,0.24453855769386854,234.75205874455742,7.160172880192543,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HPH-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,297.0,1.623,,,60.0,10.02,40.9,9.43,33.9,0.0041082,-0.107567,46.48,1.5026077834195128,10.030861620668578,1.4870008645536953e-11,0.24782022956511995,228.61769807278804,6.67234506860106,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PB-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,293.1,1.58,,,60.0,10.19,40.8,9.52,33.6,0.0042798,-0.113832,48.75,1.5466311455624888,10.206261394861377,3.4780732708949016e-11,0.25794185079463894,161.63604088939266,7.533794442309842,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60PE-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,297.2,1.583,,,60.0,10.14,41.0,9.5,33.7,0.004056000000000001,-0.10988000000000002,45.95,1.518518553324408,10.15537003908139,1.866396611071897e-11,0.2759078576947005,182.02332994521848,6.540365072039595,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,292.5,1.938,1.956,0.991,72.0,9.27,44.42,8.66,36.97,0.003986099999999999,-0.13814620000000002,45.4,1.7861476470026625,9.280336728732722,1.4354116483059987e-10,0.2334054563541177,209.31850882548036,8.872901103576444,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-320M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,320.0,292.1,1.938,1.956,0.991,72.0,9.07,45.8,8.58,37.3,0.0037187,-0.14152199999999998,45.8,1.798337317340038,9.073602699568749,7.848168902839724e-11,0.3618909032821681,911.0808307115086,4.5372493995774095,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-325M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,325.0,306.2,1.62,,,60.0,10.12,41.13,9.52,34.128,0.0057684,-0.11022840000000002,43.68,1.5012881258386586,10.131479408491174,1.256859928672678e-11,0.24475693257067532,215.77245647483906,2.953256558032323,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72-325M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,325.0,297.2,1.938,1.956,0.991,72.0,9.3,44.51,8.79,36.99,0.003999,-0.1384261,45.4,1.7773472370969199,9.303973598490593,1.2273890334308004e-10,0.24253756329475445,567.6465472540284,7.434411394320998,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-325M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,325.0,296.8,1.938,1.956,0.991,72.0,9.18,46.0,8.67,37.5,0.0037638,-0.14214000000000002,45.8,1.8086272785710282,9.184994171993559,8.204052251009266e-11,0.3540547193012396,650.8030952942377,4.816008033457984,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-60HIH-330M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,330.0,311.0,1.62,,,60.0,10.19,41.4,9.61,34.4,0.0058083,-0.110952,43.68,1.5103889807515583,10.19951165812064,1.2518788177554087e-11,0.23910359847587345,256.1557240427977,2.8525259621854753,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72-330M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,330.0,301.9,1.938,1.956,0.991,72.0,9.34,44.56,8.89,37.11,0.004016199999999999,-0.13858160000000003,45.4,1.7750234389364776,9.340002795990923,1.1691272005831815e-10,0.232612612293489,777119.8030150078,6.9500400248017185,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-330M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,330.0,301.5,1.938,1.956,0.991,72.0,9.3,46.1,8.78,37.59,0.003813000000000001,-0.142449,45.8,1.8131270009183023,9.305372708238474,8.373806858321482e-11,0.3491011431091168,604.2838618907771,4.880801504539437,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-335M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,335.0,312.0,1.812,,,60.0,10.76,39.9,10.25,32.7,0.0047344,-0.10733100000000001,45.55,1.4419822320023414,10.760006319308731,1.0346055121128202e-11,0.2688783138136464,457828.7382283072,0.5652576577168564,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72-335M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,335.0,306.6,1.938,1.956,0.991,72.0,9.45,44.6,9.0,37.21,0.004063499999999999,-0.138706,45.4,1.7785537525309179,9.450002757450932,1.2156820832412483e-10,0.22143824446418398,758961.2325711517,7.1855361974771155,-0.411,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-335M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,335.0,306.2,1.938,1.956,0.991,72.0,9.4,46.3,8.89,37.7,0.0038540000000000002,-0.143067,45.8,1.818003462141056,9.403938202530373,8.135370367936954e-11,0.3539329880115141,844.7941391072233,4.539857606701784,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-340M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,340.0,316.8,1.812,,,60.0,10.84,40.1,10.34,32.9,0.0047696,-0.107869,45.55,1.4509663536684432,10.840250761720673,1.0774788488405712e-11,0.2638624495321133,11406.323870845472,0.8385083963459691,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72-340M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,340.0,311.3,1.938,1.956,0.991,72.0,9.58,45.66,9.13,37.26,0.0041194,-0.14200259999999998,45.4,1.803093462118142,9.58000302831505,9.630764464347925e-11,0.3160641177000128,999999.9434398084,5.079938627600511,-0.411,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-340M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,340.0,310.9,1.938,1.956,0.991,72.0,9.49,46.5,8.97,37.9,0.0038909,-0.143685,45.8,1.8273486933507148,9.494479071306424,8.379297072944277e-11,0.34723981427790934,735.7119198187739,4.7109587584078145,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-340M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,340.0,310.3,1.938,1.956,0.991,72.0,9.36,47.2,8.81,38.6,0.0035568,-0.136408,45.8,1.8675721338206195,9.367636933212683,9.776976413834772e-11,0.33870809315855877,415.12839919916655,13.579193131799785,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-340M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,340.0,313.0,1.938,1.956,0.991,72.0,9.36,47.2,8.81,38.6,0.0035568,-0.133576,45.8,1.7921149238893435,9.36955568750445,3.3662417060233324e-11,0.3570618363470083,349.7497015121878,6.4690932779638,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HBD-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,345.0,321.2,1.83,,,60.0,10.88,40.7,10.24,33.7,0.004569600000000001,-0.10907600000000002,46.49,1.4664559969746214,10.892847420533155,9.453187558739433e-12,0.2370341489289218,200.73535644658938,0.20377840254236948,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIBD-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,345.0,325.3,1.83,,,60.0,10.88,40.7,10.24,33.7,0.0057664000000000005,-0.10826200000000001,42.36,1.4967749243391468,10.89180707270355,1.6601321915619942e-11,0.23045995094976718,212.364600827665,5.536670055003764,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,345.0,322.0,1.77,,,60.0,11.06,40.2,10.09,34.2,0.004424,-0.10693200000000001,45.17,1.5111998228164025,11.080640717809748,2.9271558116787247e-11,0.11970298639496126,64.1409394862886,10.68460888908741,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,345.0,316.0,1.938,1.956,0.991,72.0,9.7,45.74,9.24,37.35,0.004170999999999999,-0.1422514,45.4,1.8064081626277284,9.700003026685746,9.772685704146986e-11,0.3119856224834396,999999.9477643219,5.098375972161911,-0.411,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,345.0,315.6,1.938,1.956,0.991,72.0,9.58,46.7,9.05,38.1,0.0039278,-0.14430300000000001,45.8,1.8366915979499179,9.585003012087684,8.627774229815213e-11,0.34066632872631764,652.3237697774159,4.880346890813682,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,345.0,315.0,1.938,1.956,0.991,72.0,9.46,47.4,8.92,38.7,0.0035948000000000004,-0.136986,45.8,1.8721525299621098,9.466342418860933,9.468306157550615e-11,0.3449845262055558,514.5598105635004,13.181387271224652,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-345M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,345.0,317.7,1.938,1.956,0.991,72.0,9.46,47.4,8.92,38.7,0.0035948000000000004,-0.13414199999999998,45.8,1.7966020966355372,9.46824199951001,3.2581418064152784e-11,0.36310457879782876,416.76408613592827,6.090104665611118,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HBD-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,350.0,326.0,1.83,,,60.0,10.96,40.9,10.33,33.9,0.004603200000000001,-0.109612,46.49,1.473415800823815,10.971594986049148,9.493529126240639e-12,0.232702606144006,219.95884703541654,0.17318289439509346,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIBD-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,350.0,330.1,1.83,,,60.0,10.96,40.9,10.33,33.9,0.005808800000000001,-0.108794,42.36,1.5038775437370941,10.970591286898053,1.6673442992610575e-11,0.2261521893447386,234.02519782913456,5.505464848283544,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIH-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,350.0,326.8,1.81,,,60.0,11.02,40.5,10.52,33.3,0.0042978,-0.10975500000000002,44.74,1.471564753778173,11.020004226673331,1.229266888336627e-11,0.25325410436505175,660307.8875533488,1.100141172256728,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,350.0,326.8,1.77,,,60.0,11.16,40.4,10.18,34.4,0.004464,-0.107464,45.17,1.5195139554784252,11.180289889719349,2.99439615627122e-11,0.11581786936356875,63.703028578957905,10.80820072218361,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,350.0,328.0,1.77,,,60.0,11.15,40.1,10.42,33.6,0.0041255,-0.10626500000000001,44.02,1.475530419033273,11.165405326108331,1.7102886623828237e-11,0.18017854023664942,130.40884145951875,6.238101643010689,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,350.0,326.5,1.91,,,72.0,9.51,47.9,8.97,39.0,0.0038991000000000004,-0.128851,43.73,1.777872304469623,9.519066545972562,1.8718992333467153e-11,0.3873683446173715,406.3149318901581,6.671318719182012,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HV-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,350.0,320.3,1.938,1.956,0.991,72.0,9.68,46.9,9.16,38.2,0.0039688,-0.144921,45.8,1.8413404998235727,9.68356474353388,8.357291095691147e-11,0.3467148639595008,941.4983881612382,4.517210503567815,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,350.0,319.7,1.938,1.956,0.991,72.0,9.57,47.5,9.03,38.8,0.0036366000000000002,-0.137275,45.8,1.8759263817455236,9.575832016182302,9.563073857606946e-11,0.33941243685859807,556.9561420742767,13.163984444272407,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-350M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,350.0,322.4,1.938,1.956,0.991,72.0,9.57,47.5,9.03,38.8,0.0036366000000000002,-0.134425,45.8,1.8002293964828373,9.57771401912093,3.290695224646855e-11,0.3573502289433286,443.3281432533788,6.073514515307084,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HBD-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,355.0,330.7,1.83,,,60.0,11.04,41.1,10.42,34.1,0.0046368,-0.11014800000000001,46.49,1.4803813936516792,11.050381452628642,9.534739917034553e-12,0.22844424003013422,242.93559883527737,0.14368949587443178,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIBD-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,355.0,334.9,1.83,,,60.0,11.04,41.1,10.42,34.1,0.0058512,-0.10932600000000002,42.36,1.5109860934325692,11.049414244695821,1.674705551870136e-11,0.22191715948695806,260.2402569280117,5.475392822152313,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIH-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,355.0,331.6,1.81,,,60.0,11.1,40.7,10.6,33.5,0.004329,-0.11029700000000002,44.74,1.479703896441448,11.10000423527629,1.2584400062886083e-11,0.24876166148873993,651976.1159025193,1.2334649981157795,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,355.0,331.6,1.77,,,60.0,11.25,40.6,10.27,34.6,0.0045000000000000005,-0.10799600000000001,45.17,1.5270972161469873,11.269588495579438,3.024286292448575e-11,0.11229766708165156,64.49442490631887,10.822307151048834,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,355.0,332.8,1.77,,,60.0,11.25,40.3,10.51,33.8,0.0041624999999999995,-0.106795,44.02,1.4838561755242456,11.265486797521902,1.755609624346724e-11,0.17588936428016863,127.77046717509528,6.38831834580247,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,355.0,331.2,1.91,,,72.0,9.61,48.1,9.06,39.2,0.0039401,-0.12938900000000003,43.73,1.7865646977005418,9.619556096603034,1.9268601752458637e-11,0.38020337822624617,382.34797764530464,6.83342846699005,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,355.0,324.4,1.938,1.956,0.991,72.0,9.63,47.7,9.1,39.032,0.0036594,-0.137853,45.8,1.8842181828461186,9.634649665507029,9.689015146204693e-11,0.33002396006407364,683.5181708401548,13.220490629618414,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-355M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,355.0,327.2,1.938,1.956,0.991,72.0,9.63,47.7,9.1,39.032,0.0036594,-0.134991,45.8,1.8081782125847476,9.63644273330399,3.334360767836957e-11,0.3479226302348113,520.0424788149811,6.127314872073597,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HBD-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,360.0,335.5,1.83,,,60.0,11.11,41.3,10.5,34.3,0.0046662,-0.110684,46.49,1.4873893063588797,11.119240664321769,9.574149869499313e-12,0.22445634990215838,269.8626387021162,0.12057178818676603,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIBD-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,360.0,339.7,1.83,,,60.0,11.11,41.3,10.5,34.3,0.005888299999999999,-0.109858,42.36,1.5181382669576,11.118309411267246,1.681736321711067e-11,0.21794565951396647,291.40166640394773,5.451925099228094,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIH-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,360.0,336.4,1.81,,,60.0,11.2,40.9,10.69,33.7,0.0043679999999999995,-0.11083900000000001,44.74,1.4873214638156786,11.200004274740403,1.2779351262501292e-11,0.24409073102710638,639538.076123511,1.2861431684993732,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,360.0,337.6,1.77,,,60.0,11.35,40.5,10.59,34.0,0.0041995,-0.10732500000000002,44.02,1.4928822326395543,11.366164048153669,1.8227048814365362e-11,0.17156196946977328,120.46662697019391,6.641564485272665,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,360.0,336.0,1.91,,,72.0,9.72,48.2,9.16,39.3,0.0039852,-0.12965800000000002,43.73,1.7910538270908338,9.730012588323804,1.9707132174957014e-11,0.37434970320047595,363.4104422782897,6.931577528167454,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,360.0,335.9,1.95,,,72.0,9.64,47.7,9.14,39.4,0.004338000000000001,-0.128313,44.64,1.7503698820571132,9.645026219181974,1.3983754408457517e-11,0.31635620764107775,606.7530625336498,3.9986479473848093,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-360MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,360.0,335.9,1.95,,,72.0,9.64,47.7,9.14,39.4,0.004338000000000001,-0.128313,44.64,1.7503698820571132,9.645026219181974,1.3983754408457517e-11,0.31635620764107775,606.7530625336498,3.9986479473848093,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIBD-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,360.0,335.6,1.95,,,72.0,9.64,47.7,9.14,39.4,0.0047236000000000005,-0.127836,45.69,1.731665642211298,9.645441434618416,1.0412796712533273e-11,0.3208719455343177,568.4540569291204,1.8645862484059545,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,360.0,329.2,1.938,1.956,0.991,72.0,9.7,47.9,9.18,39.196,0.0036859999999999996,-0.13843099999999997,45.8,1.8907025297404518,9.70345594351192,9.59326259579856e-11,0.32907836192162443,923.6437140860793,13.05763050890126,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-360M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,360.0,336.0,1.88,,,72.0,9.87,47.84,9.23,39.01,0.0037505999999999998,-0.12581920000000002,44.48,1.7530541835143334,9.888398396385682,1.3577045335481152e-11,0.3728213704703303,200.00367797506522,6.078455414534571,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HBD-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,365.0,340.3,1.83,,,60.0,11.18,41.5,10.58,34.5,0.0046956,-0.11122000000000001,46.49,1.4944006192276633,11.188135729289845,9.61407717520723e-12,0.2205280410372707,303.04640471821716,0.09813587922816709,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIBD-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,365.0,344.6,1.83,,,60.0,11.18,41.5,10.58,34.5,0.0059254,-0.11039000000000002,42.36,1.5252939135827601,11.187240276129247,1.6888557249473427e-11,0.21403348096007213,330.4976627451785,5.4291529332344854,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIH-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,341.1,1.81,,,60.0,11.28,41.1,10.77,33.9,0.0043992,-0.11138100000000002,44.74,1.495459633659922,11.280004278218717,1.3077037275047228e-11,0.23973833201851782,632106.6423420802,1.4171182107118037,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,341.2,1.77,,,60.0,11.41,41.0,10.43,35.0,0.004564,-0.10906000000000002,45.17,1.542410182784778,11.42825556850408,3.0859269044313114e-11,0.10558403761803749,65.99158340992919,10.871475718920136,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,342.4,1.77,,,60.0,11.43,40.7,10.68,34.2,0.0042290999999999995,-0.107855,44.02,1.4998983633999459,11.44506579964312,1.8267020109057357e-11,0.16792132960333597,127.39720750577472,6.593843533364166,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,365.0,340.8,1.91,,,72.0,9.84,48.3,9.25,39.5,0.0040344000000000005,-0.12992700000000001,43.73,1.7996763750031324,9.852162310379942,2.1399629622708025e-11,0.35574766867421576,287.82006734207795,7.552061585700036,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,365.0,340.7,1.95,,,72.0,9.72,47.9,9.22,39.6,0.004374,-0.128851,44.64,1.7581139387800493,9.724707514571417,1.4194847608288686e-11,0.31075258481249707,641.6369233007914,4.05379872759026,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-365MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,365.0,340.7,1.95,,,72.0,9.72,47.9,9.22,39.6,0.004374,-0.128851,44.64,1.7581139387800493,9.724707514571417,1.4194847608288686e-11,0.31075258481249707,641.6369233007914,4.05379872759026,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIBD-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,365.0,340.4,1.95,,,72.0,9.72,47.9,9.22,39.6,0.0047628,-0.128372,45.69,1.739325439783883,9.725116724982323,1.0570450789004869e-11,0.3152517881930869,598.8688902280006,1.9191545267785515,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,339.5,1.94,,,72.0,9.71,48.4,9.13,40.0,0.005340500000000001,-0.129228,46.89,1.7633153082727884,9.72191708609833,1.1448421254057653e-11,0.3203642453427382,261.0316658944062,2.932889505682456,-0.324,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,343.3,1.936,,,72.0,9.71,48.4,9.13,40.0,0.0039811000000000004,-0.129228,42.59,1.7755442497745193,9.721591911244674,1.383525202881158e-11,0.3173989955921277,265.8702434256147,4.721423804181126,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-365MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,343.3,1.94,,,72.0,9.71,48.4,9.13,40.0,0.0039811000000000004,-0.129228,42.59,1.7755442497745193,9.721591911244674,1.383525202881158e-11,0.3173989955921277,265.8702434256147,4.721423804181126,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,333.9,1.938,1.956,0.991,72.0,9.74,48.0,9.29,39.3,0.0037012,-0.13871999999999998,45.8,1.8941629201586998,9.740003015445625,9.618259418536517e-11,0.30955529752169514,999999.8972659055,13.025197922912943,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-365M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,365.0,340.8,1.88,,,72.0,9.9,48.13,9.28,39.34,0.003762,-0.12658190000000002,44.48,1.7638297301137396,9.915848909750093,1.368445212787812e-11,0.36230509228661306,226.31338626816975,6.110947695785881,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HIH-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,345.9,1.81,,,60.0,11.37,41.3,10.86,34.1,0.0044342999999999995,-0.11192300000000001,44.74,1.5036226728139659,11.370004282976527,1.339654199485685e-11,0.23523459779217665,624485.9153840815,1.5505720729056602,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPB-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,346.0,1.77,,,60.0,11.5,41.2,10.52,35.2,0.0046,-0.10959200000000001,45.17,1.5500019096523567,11.517597107661977,3.1163791194872414e-11,0.10223285439116882,66.81085610877976,10.886215810867267,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,347.2,1.77,,,60.0,11.52,40.9,10.76,34.4,0.0042623999999999995,-0.108385,44.02,1.5082683519081055,11.535145628845815,1.8734907618542096e-11,0.16397427021644861,124.72137094573513,6.746664072219566,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,370.0,345.6,1.91,,,72.0,9.95,48.4,9.35,39.6,0.0040795,-0.130196,43.73,1.8041444762092502,9.962575501629923,2.18686159566641e-11,0.3502840176286955,277.1520463932818,7.645761653043931,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,370.0,345.5,1.95,,,72.0,9.8,48.1,9.3,39.8,0.00441,-0.12938900000000003,44.64,1.7658598757784867,9.804397140838809,1.440766249946055e-11,0.3052450229539351,680.3059938589585,4.108714100908634,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-370MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,370.0,345.5,1.95,,,72.0,9.8,48.1,9.3,39.8,0.00441,-0.12938900000000003,44.64,1.7658598757784867,9.804397140838809,1.440766249946055e-11,0.3052450229539351,680.3059938589585,4.108714100908634,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIBD-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,370.0,345.2,1.95,,,72.0,9.8,48.1,9.3,39.8,0.004802000000000001,-0.12890800000000002,45.69,1.7469872207415649,9.804800332460795,1.072942112502152e-11,0.3097279503003796,632.3174421539676,1.9735069002230314,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,344.2,1.94,,,72.0,9.79,48.6,9.21,40.2,0.0053844999999999995,-0.12976200000000002,46.89,1.770938689481826,9.801500231287633,1.1609282322248738e-11,0.31475732643473875,267.94888910368104,2.9793479446287474,-0.324,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,348.1,1.936,,,72.0,9.79,48.6,9.21,40.2,0.0040139,-0.12976200000000002,42.59,1.7832178866281938,9.801179045728373,1.4028582637888245e-11,0.3118042096250647,273.0611631607304,4.767741300971173,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-370MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,348.1,1.94,,,72.0,9.79,48.6,9.21,40.2,0.0040139,-0.12976200000000002,42.59,1.7832178866281938,9.801179045728373,1.4028582637888245e-11,0.3118042096250647,273.0611631607304,4.767741300971173,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PE-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,338.6,1.938,1.956,0.991,72.0,9.84,48.3,9.39,39.4,0.0037392,-0.139587,45.8,1.9032827354198505,9.840003173814226,9.371565190408188e-11,0.3225010758139378,999999.8013918315,12.696711175843257,-0.416,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-370M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,370.0,345.6,1.88,,,72.0,9.93,48.4,9.32,39.69,0.0037733999999999997,-0.127292,44.48,1.7755860123057483,9.944271149296371,1.4140769894916348e-11,0.3472503806161329,241.6200868176698,6.363314791038329,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,375.0,352.0,1.77,,,60.0,11.6,41.1,10.84,34.6,0.004292,-0.10891500000000001,44.02,1.5159858478255575,11.614666503104422,1.8990092776035743e-11,0.16033483684857758,126.8116946483748,6.802025934557694,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,375.0,350.4,1.91,,,72.0,10.03,48.6,9.43,39.8,0.0041123,-0.13073400000000002,43.73,1.8120054825351528,10.042118906105967,2.2188580615100616e-11,0.34448253589459427,285.10492952619217,7.7007091738665725,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,375.0,350.3,1.95,,,72.0,9.87,48.3,9.38,40.0,0.004441499999999999,-0.12992700000000001,44.64,1.772760011122873,9.873330745909245,1.443554173833354e-11,0.30019954318304737,889.5813812957631,4.0590329051148775,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-375MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,375.0,350.3,1.95,,,72.0,9.87,48.3,9.38,40.0,0.004441499999999999,-0.12992700000000001,44.64,1.772760011122873,9.873330745909245,1.443554173833354e-11,0.30019954318304737,889.5813812957631,4.0590329051148775,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIBD-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,375.0,349.9,1.95,,,72.0,9.87,48.3,9.38,40.0,0.0048363,-0.129444,45.69,1.753818261582578,9.873716564289413,1.0750167857301126e-11,0.30466192428350497,809.0841411316361,1.9247252488667181,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,375.0,349.0,1.94,,,72.0,9.87,48.8,9.28,40.4,0.0054285,-0.130296,46.89,1.7794815204281005,9.88190826405101,1.1923951941647138e-11,0.3091736870484178,256.2543366645502,3.1382074146637633,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +LONGi Green Energy Technology Co Ltd LR6-72HPH-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,375.0,352.9,1.936,,,72.0,9.87,48.8,9.28,40.4,0.0040467,-0.130296,42.59,1.7918218473512795,9.881583368718386,1.4407308505082945e-11,0.306226012113944,260.9302035063924,4.927878298532354,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-375MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,375.0,352.9,1.94,,,72.0,9.87,48.8,9.28,40.4,0.0040467,-0.130296,42.59,1.7918218473512795,9.881583368718386,1.4407308505082945e-11,0.306226012113944,260.9302035063924,4.927878298532354,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-375M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,375.0,350.4,1.88,,,72.0,9.96,48.71,9.36,40.08,0.0037848,-0.1281073,44.48,1.788953431862155,9.972762692591898,1.4638016382206307e-11,0.331739729200223,258.8895485238465,6.631555065341871,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-60HPH-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,380.0,356.9,1.77,,,60.0,11.69,41.3,10.92,34.8,0.0043253,-0.109445,44.02,1.524354968185041,11.704731155101351,1.946785398044799e-11,0.1565020771926589,124.19319942449192,6.952236829990765,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72BP-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,380.0,355.2,1.91,,,72.0,10.11,48.8,9.51,40.0,0.0041451,-0.131272,43.73,1.8198688081799852,10.121672447494737,2.2511197453778034e-11,0.33877826313064324,293.4301720840341,7.755478325618902,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,380.0,355.1,1.95,,,72.0,9.97,48.5,9.47,40.2,0.0044865,-0.130465,44.64,1.7813129915699515,9.973764996869676,1.484422550789222e-11,0.2942165220292969,779.1078937434833,4.212410524965056,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-380MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,380.0,355.1,1.95,,,72.0,9.97,48.5,9.47,40.2,0.0044865,-0.130465,44.64,1.7813129915699515,9.973764996869676,1.484422550789222e-11,0.2942165220292969,779.1078937434833,4.212410524965056,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIBD-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,380.0,354.7,1.95,,,72.0,9.97,48.5,9.47,40.2,0.0048853,-0.12998,45.69,1.7622726583163586,9.974155933583672,1.1055501948818676e-11,0.2986628175571265,716.4860198676101,2.0761511988118384,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,380.0,353.8,1.94,,,72.0,9.96,49.0,9.36,40.6,0.005478,-0.13083,46.89,1.7879674342672212,9.972264858401042,1.224676422451316e-11,0.30337439825542206,246.36313939840568,3.288825714209078,-0.324,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,380.0,357.7,1.94,,,72.0,9.96,49.0,9.36,40.6,0.004083600000000001,-0.13083,42.59,1.8003684323979054,9.971936380199708,1.479588108027601e-11,0.30043538194921643,250.69044117814633,5.079700055882467,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-380MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,380.0,357.7,1.94,,,72.0,9.96,49.0,9.36,40.6,0.004083600000000001,-0.13083,42.59,1.8003684323979054,9.971936380199708,1.479588108027601e-11,0.30043538194921643,250.69044117814633,5.079700055882467,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72PH-380M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,380.0,355.2,1.88,,,72.0,10.0,49.03,9.4,40.41,0.0038,-0.1289489,44.48,1.8019915228114685,10.01238238875931,1.49871253512074e-11,0.32442473405955247,262.0049671751278,6.800331859841528,-0.349,N,2025.7.3,6/23/2025,4.0,bootstrapping +LONGi Green Energy Technology Co Ltd LR6-72HBD-385M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,385.0,359.8,1.95,,,72.0,10.03,48.7,9.53,40.4,0.0045135,-0.131003,44.64,1.7891535814133825,10.033549639974687,1.5050792992629224e-11,0.2895590749491036,818.1893354152717,4.277534279522984,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-385MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,385.0,359.8,1.95,,,72.0,10.03,48.7,9.53,40.4,0.0045135,-0.131003,44.64,1.7891535814133825,10.033549639974687,1.5050792992629224e-11,0.2895590749491036,818.1893354152717,4.277534279522984,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIBD-385M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,385.0,359.5,1.95,,,72.0,10.03,48.7,9.53,40.4,0.0049147,-0.13051600000000002,45.69,1.7700273448444765,10.033934904085283,1.1209896805027497e-11,0.2939997647070485,749.4000229826398,2.140556341072893,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-385M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,385.0,358.6,1.94,,,72.0,10.03,49.2,9.43,40.8,0.0055165,-0.131364,46.89,1.7956459488058811,10.041887617657272,1.2410211780900162e-11,0.29834134647586846,251.72106008417916,3.3399707470739943,-0.324,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-385M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,385.0,362.6,1.936,,,72.0,10.03,49.2,9.43,40.8,0.0041123,-0.131364,42.59,1.8080980655384384,10.041563024111326,1.4992264512213083e-11,0.2954106030133819,256.24510816847726,5.13080974669038,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-385MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,385.0,362.5,1.94,,,72.0,10.03,49.2,9.43,40.8,0.0041123,-0.131364,42.59,1.8080980655384384,10.041563024111326,1.4992264512213083e-11,0.2954106030133819,256.24510816847726,5.13080974669038,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPB-390M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,390.0,361.5,1.9,,,54.0,13.59,36.4,12.81,30.45,0.005300099999999999,-0.09828,46.32,1.363170897301633,13.600824667880396,3.3874686602122e-11,0.13400645804219288,168.24052256348287,8.364978024658024,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HBD-390M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,390.0,364.6,1.95,,,72.0,10.07,49.1,9.56,40.8,0.0045315,-0.13207900000000003,44.64,1.8060831782026896,10.074160201396685,1.5610451113205968e-11,0.2825260255065209,683.8700453038168,4.557419065934653,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-390M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,390.0,363.3,1.94,,,72.0,10.12,49.5,9.52,41.0,0.005566,-0.132165,46.89,1.8050155634507032,10.131736811530303,1.2234463222438061e-11,0.30342252468796244,261.6243701320432,3.1421287900865926,-0.324,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-390M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,390.0,367.4,1.936,,,72.0,10.12,49.5,9.52,41.0,0.0041492000000000005,-0.132165,42.59,1.8175305633310614,10.131409270363477,1.4781944651137453e-11,0.30050775883950537,266.5497827271286,4.931434839454336,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-390MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,390.0,367.4,1.94,,,72.0,10.12,49.5,9.52,41.0,0.0041492000000000005,-0.132165,42.59,1.8175305633310614,10.131409270363477,1.4781944651137453e-11,0.30050775883950537,266.5497827271286,4.931434839454336,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-390M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,390.0,364.2,2.108,,,78.0,9.744,51.934999999999995,8.99,43.435,0.00457968,-0.1391858,44.81,1.9342747481841907,9.76516855630971,2.0421499161812482e-11,0.2720540182064206,125.22792400799598,7.6474160647133225,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABB-395M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,395.0,369.3,1.9,,,54.0,13.65,36.81,12.87,30.7,0.0039585,-0.09681030000000002,45.02,1.3348485943638024,13.662827764668927,1.4190339834762709e-11,0.15040275187433996,160.0432846878213,3.795678557114902,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABD-395M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,395.0,368.4,1.9,,,54.0,13.72,36.63,12.96,30.49,0.004390400000000001,-0.0959706,45.31,1.341168190095937,13.730796590527047,1.8628878161922753e-11,0.15166352527111635,192.72969321729252,6.420152268766165,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPB-395M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,395.0,366.3,1.9,,,54.0,13.66,36.65,12.87,30.7,0.0053274,-0.098955,46.32,1.373784953151909,13.67102918454965,3.4864188049483654e-11,0.13054524095516087,161.68448341874594,8.574902004175472,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HIH-395M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,395.0,368.1,1.94,,,72.0,10.18,49.7,9.57,41.3,0.005599,-0.132699,46.89,1.8158941895235803,10.191825272468495,1.2977454465993594e-11,0.28667558193781634,246.7898684512733,3.592750928261926,-0.324,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-395M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,395.0,372.2,1.936,,,72.0,10.18,49.7,9.57,41.3,0.0041738,-0.132699,42.59,1.828487143169153,10.191502288675542,1.5674346463736726e-11,0.2837505364462624,251.13089165363363,5.385164476853165,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-72HPH-395MC,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,395.0,372.2,1.94,,,72.0,10.18,49.7,9.57,41.3,0.0041738,-0.132699,42.59,1.828487143169153,10.191502288675542,1.5674346463736726e-11,0.2837505364462624,251.13089165363363,5.385164476853165,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-395M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,395.0,369.0,2.108,,,78.0,9.815,52.145,9.06,43.6495,0.0046130500000000005,-0.13974860000000003,44.81,1.9425068185854868,9.835670415580731,2.069786031132977e-11,0.26632302131898217,126.45901827510761,7.6996734555789885,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABB-400M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,400.0,374.1,1.9,,,54.0,13.72,37.05,12.93,30.94,0.003978800000000001,-0.0974415,45.02,1.344712508190232,13.733088776380084,1.459698130326194e-11,0.14705512892347877,154.14705837116276,3.9933098594505267,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABD-400M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,400.0,373.1,1.9,,,54.0,13.79,36.87,13.02,30.73,0.0044128,-0.0965994,45.31,1.3511448366629428,13.801122424757027,1.9166537526112898e-11,0.1483121999366554,183.8830376927801,6.624478330593722,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPB-400M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,400.0,371.1,1.9,,,54.0,13.71846955,36.9,12.92824822,30.94,0.0053502031245,-0.09963000000000001,46.32,1.3836898432840385,13.72917492363608,3.5382571695459554e-11,0.12817477764321455,164.25039014485796,8.666238894990475,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-400M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,400.0,373.7,2.108,,,78.0,9.8793,52.376,9.14,43.832,0.004643271,-0.14036768000000002,44.81,1.9486124334805808,9.898890233565924,2.0182681986748704e-11,0.2675450161165187,134.92220380473475,7.413504771344548,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABB-405M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,405.0,378.9,1.9,,,54.0,13.79,37.29,12.99,31.18,0.0039991,-0.09807270000000001,45.02,1.337992978183355,13.79000405171434,1.0857523552250022e-11,0.14637500306772674,498191.6703282716,1.4173558631659071,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABD-405M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,405.0,377.9,1.9,,,54.0,13.87,37.11,13.08,30.97,0.0044383999999999995,-0.0972282,45.31,1.361596879089969,13.882088041104849,1.9898452279962592e-11,0.14484245468502985,166.19440984755997,6.904460635513418,-0.349,N,2025.7.3,6/23/2025,4.0,bootstrapping +LONGi Green Energy Technology Co Ltd LR5-54HPB-405M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,405.0,375.8,1.9,,,54.0,13.78,37.15,12.99,31.18,0.0053742,-0.100305,46.32,1.3935603050955947,13.79035409686241,3.5889070347167565e-11,0.12580275241293784,167.42763430983194,8.750857585231191,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPH-405M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,405.0,376.5,1.9,,,54.0,13.83,37.0,13.07,31.0,0.0049788,-0.10064000000000001,45.86,1.3811604017999717,13.838789223380566,3.1700101319450876e-11,0.13047207498430516,205.3001427349178,6.866661044680625,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-405M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,405.0,378.5,2.108,,,78.0,9.953,52.5896,9.208,43.985,0.0046779099999999995,-0.14094012800000003,44.81,1.9559833815579002,9.972971315613805,2.0173601242028996e-11,0.2698656749319399,134.49154408652387,7.34474609909441,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABB-410M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,410.0,383.7,1.9,,,54.0,13.87,37.53,13.05,31.42,0.0040222999999999995,-0.09870390000000001,45.02,1.3649237535888599,13.884169786070661,1.557784828100946e-11,0.14029988579389657,137.33160226414694,4.459542675048004,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABD-410M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,410.0,382.7,1.9,,,54.0,13.94,37.35,13.14,31.21,0.0044608,-0.097857,45.31,1.37158156927865,13.952343309533783,2.0459436449304728e-11,0.1415511075651022,159.8617003464514,7.104344849986059,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPB-410M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,410.0,380.6,1.9,,,54.0,13.84191303,37.4,13.04901337,31.42,0.0053983460817,-0.10098,46.32,1.3735037361167155,13.85322292711152,2.0340271352449024e-11,0.12857553822657938,157.36053200687272,3.834246030347341,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPH-410M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,410.0,381.3,1.9,,,54.0,13.88340701,37.25,13.12,31.25,0.0049980265236,-0.10132000000000001,45.86,1.3914381403232419,13.892091111173634,3.240180922976734e-11,0.12729423968988035,203.50727397028524,7.023190379291221,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-410M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,410.0,383.3,2.108,,,78.0,10.022,52.812,9.286,44.153,0.00471034,-0.14153616000000002,44.81,1.9623200427259309,10.041338891322031,1.9818442495048036e-11,0.27163881189133704,140.77147111758902,7.123743686398371,-0.337,N,2025.7.3,6/23/2025,4.0,bootstrapping +LONGi Green Energy Technology Co Ltd LR4-72HBD-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,415.0,388.5,2.11,,,72.0,10.89,49.0,10.23,40.6,0.004464900000000001,-0.12691,44.84,1.773227021772644,10.90417617956225,1.0653334123164168e-11,0.28071850513839164,215.64515115641953,4.735083367857311,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIBD-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,415.0,390.7,2.18,,,72.0,10.89,49.0,10.23,40.6,0.005336100000000001,-0.13034,43.11,1.7867336775541902,10.903775422937699,1.3132750952836678e-11,0.2777805334513087,219.59616308792565,3.6005873599664007,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABB-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,415.0,388.5,1.9,,,54.0,13.94,37.77,13.11,31.66,0.0040426,-0.09933510000000001,45.02,1.374798210991516,13.954339079570445,1.600919903105793e-11,0.1370422359255011,133.2281313766863,4.650922063298882,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABD-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,415.0,387.5,1.9,,,54.0,14.0,37.59,13.2,31.45,0.0044800000000000005,-0.09848580000000003,45.31,1.381091185900156,14.01194127009282,2.0835433696844445e-11,0.1384383409093139,162.30583070297018,7.22439054867614,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPB-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,415.0,385.4,1.9,,,54.0,13.91,37.65,13.11,31.66,0.0054249,-0.10165500000000001,46.32,1.4138332883086646,13.920252990650173,3.7263740066058414e-11,0.12099342749165627,164.14908977390812,9.000489624677574,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPH-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,415.0,386.1,1.9,,,54.0,13.9449604,37.5,13.17878692,31.49,0.0050201857439999996,-0.10200000000000001,45.86,1.3829045817937815,13.954164304247543,2.3011996608086895e-11,0.12808139871849716,194.05786901412452,4.0680994036889535,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-415M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,415.0,388.1,2.108,,,78.0,10.102,53.032,9.353,44.373,0.00474794,-0.14212576000000002,44.81,1.9720876155547915,10.121654261294802,2.0395775757574035e-11,0.2660393343138004,136.74028868506082,7.3077291463563245,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,420.0,393.3,2.11,,,72.0,10.96,49.2,10.3,40.8,0.004493600000000001,-0.127428,44.84,1.7808640385632277,10.973777394577416,1.0792805205298759e-11,0.2762693403914646,219.77391764371993,4.789883573708468,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIBD-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,420.0,395.5,2.18,,,72.0,10.96,49.2,10.3,40.8,0.005370400000000001,-0.13087200000000002,43.11,1.7944353220209521,10.973380898604884,1.3305371854349499e-11,0.2733358250107641,223.8833684250383,3.655289075831533,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,420.0,391.2,2.17,,,72.0,11.03682874,48.8,10.44776119,40.2,0.0044147314960000005,-0.131272,45.62,1.7741504810205706,11.044502103806275,1.2384723852987765e-11,0.2978345583145372,428.3843597782546,1.9268937593859137,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,420.0,392.7,2.12,,,72.0,11.16,48.1,10.43,40.3,0.0045756,-0.12746500000000002,45.1,1.7629319000636712,11.175608718948023,1.5373240717351546e-11,0.2177675986754403,155.7005681507951,5.262223064010874,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HABD-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,420.0,392.3,1.9,,,54.0,14.07,37.84,13.25,31.7,0.004502400000000001,-0.09914080000000003,45.31,1.3919923350896164,14.082796270306611,2.1620801605031384e-11,0.13504430563874803,148.48650005028364,7.5086966824255335,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPB-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,420.0,390.2,1.9,,,54.0,13.97321236,37.89,13.1661442,31.9,0.0054495528204,-0.102303,46.32,1.423904078610052,13.98347496577335,3.816537507988178e-11,0.11785411537614258,160.46612663666454,9.172842926292088,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPH-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,420.0,390.8,1.9,,,54.0,14.00539017,37.75,13.23668453,31.73,0.0050419404612,-0.10268000000000001,45.86,1.411415682041387,14.01380979694902,3.3501004026794925e-11,0.12263358196871225,203.9913634416652,7.236446251103362,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR6-78HBD-420M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,420.0,392.9,2.108,,,78.0,10.182,53.249,9.419,44.593,0.0047855400000000005,-0.14270732000000003,44.81,1.9819072696422515,10.201989813427033,2.102829100974873e-11,0.26017912430621765,132.52469119716392,7.508876638059383,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-425M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,425.0,398.1,2.11,,,72.0,11.22,48.7,10.52,40.4,0.0046002000000000005,-0.12613300000000002,44.84,1.765029440252233,11.23597430882295,1.1415892532401837e-11,0.2653813228775244,186.39795217757174,5.07916493856684,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIBD-425M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,425.0,400.3,2.18,,,72.0,11.02,49.4,10.37,41.0,0.0053998,-0.131404,43.11,1.8013535007097503,11.032249165149873,1.3321282498037106e-11,0.26926249897819116,242.24285614902558,3.614173652501233,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-425M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,425.0,396.0,2.17,,,72.0,11.10838987,49.0,10.51980198,40.4,0.004443355948,-0.13181,45.62,1.7696183451383547,11.108402436824637,1.0476343019114835e-11,0.2956264893184177,261318.9224349686,0.4614888537903362,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-425M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,425.0,397.5,2.12,,,72.0,11.23,48.3,10.5,40.5,0.0046043,-0.127995,45.1,1.7706019451201997,11.245189988226574,1.5557702801018257e-11,0.2138203083715877,158.0779414848141,5.309143787655106,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-54HPH-425M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,425.0,395.6,1.9,,,54.0,14.07776965,37.96,13.30619912,31.94,0.005067997074,-0.1032512,45.86,1.3969923330497898,14.08680154456552,2.196648282118373e-11,0.12365472897679115,192.7372810351553,3.5982664767928383,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-430M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,430.0,402.9,2.11,,,72.0,11.3,48.9,10.6,40.6,0.004633,-0.126651,44.84,1.772624734577569,11.31551597049975,1.1564972758718278e-11,0.2609256717489563,190.02743658279687,5.127640246209294,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIBD-430M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,430.0,405.2,2.18,,,72.0,11.09,49.6,10.44,41.2,0.0054341,-0.13193600000000003,43.11,1.8090579509505689,11.10188161346733,1.3494988597040434e-11,0.2649343086068243,247.2830398095691,3.6686966649288606,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-430M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,430.0,400.8,2.17,,,72.0,11.19,49.2,10.6,40.6,0.004476,-0.13234800000000002,45.62,1.777691049712387,11.190015027130077,1.069388946309726e-11,0.2908175776964597,216549.72020666313,0.5697405276163678,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-430M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,430.0,402.3,2.12,,,72.0,11.31,48.5,10.57,40.7,0.004637100000000001,-0.128525,45.1,1.7790497160785657,11.32537314661119,1.5929298152120795e-11,0.2096208022947828,154.21768687585356,5.4525829283566365,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-435M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,435.0,407.7,2.11,,,72.0,11.36,49.1,10.66,40.8,0.0046576,-0.127169,44.84,1.780319823788851,11.375135330908641,1.171070645627112e-11,0.2569796926451043,192.87911530884293,5.188275909621149,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIBD-435M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,435.0,410.0,2.18,,,72.0,11.16,49.8,10.51,41.4,0.005468400000000001,-0.132468,43.11,1.81676306360525,11.171521638084238,1.3669758103908511e-11,0.2606639094002409,252.48226156493965,3.722854759359131,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-435M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,435.0,405.6,2.17,,,72.0,11.26,49.4,10.67,40.8,0.004504,-0.132886,45.62,1.7974312692931103,11.26677262280202,1.2934388604444415e-11,0.28416688312325766,472.4490389669566,2.117529141353413,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-435M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,435.0,407.1,2.12,,,72.0,11.39,48.7,10.64,40.9,0.0046699,-0.12905500000000003,45.1,1.7874968618556537,11.405542803689757,1.6306291004335413e-11,0.20547697216891703,150.57661193623903,5.594771082871409,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-440M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,440.0,412.5,2.11,,,72.0,11.45,49.2,10.73,41.0,0.0046945,-0.127428,44.84,1.7876565936776858,11.465700926080746,1.2475809757389594e-11,0.24287753496983178,177.11997382937432,5.67033923411089,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-440M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,440.0,410.4,2.17,,,72.0,11.33,49.6,10.74,41.0,0.0045320000000000004,-0.13342400000000001,45.62,1.8051862178159441,11.336476444433929,1.3113992235702268e-11,0.2798457714371702,489.56686866025143,2.179398950493462,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-440M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,440.0,411.9,2.12,,,72.0,11.46,48.9,10.71,41.1,0.004698600000000001,-0.129585,45.1,1.7951666055316327,11.475127720715053,1.6495774477805363e-11,0.201688491560652,152.78905092110557,5.639651679653171,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-445M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,445.0,417.3,2.11,,,72.0,11.52,49.4,10.8,41.2,0.0047232,-0.127946,44.84,1.7952995585506628,11.535287602646617,1.2629740745353623e-11,0.23887957464576332,180.00812630907944,5.7218817751590425,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-445M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,445.0,415.1,2.17,,,72.0,11.4,49.8,10.8,41.2,0.004560000000000001,-0.133962,45.62,1.813732160733715,11.407011020908683,1.3440342016631745e-11,0.27553629398261215,448.0251621442468,2.3352684303934685,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-445M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,445.0,416.7,2.12,,,72.0,11.53,49.1,10.78,41.3,0.0047273,-0.130115,45.1,1.7672064016421838,11.530005358311554,9.894704511017995e-12,0.2049164016517749,440940.83293849806,1.191995485909948,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-450M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,450.0,422.2,2.11,,,72.0,11.58,49.6,10.87,41.4,0.0047478,-0.12846400000000002,44.84,1.80219332119643,11.594207371909429,1.264093838893258e-11,0.23521965183016758,191.72043885667352,5.679599761929699,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HIH-450M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,450.0,419.9,2.17,,,72.0,11.5,50.0,10.9,41.4,0.0046,-0.1345,45.62,1.8095946034097687,11.50000914561046,1.1505881170433361e-11,0.2728038814128316,343034.8415066503,0.9456299433382768,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-450M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,450.0,421.5,2.12,,,72.0,11.6,49.3,10.85,41.5,0.004756,-0.130645,45.1,1.7752739600842165,11.60000522564254,1.0091116050212471e-11,0.20110860376726208,446427.7923063699,1.3041939824257833,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HBD-455M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,455.0,427.0,2.11,,,72.0,11.65,49.8,10.93,41.6,0.0047765,-0.128982,44.84,1.7813080862051711,11.650006383063628,8.409271846591846e-12,0.2368100132833699,432214.1022740782,2.099231182516898,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-455M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,455.0,426.3,2.12,,,72.0,11.66,49.5,10.92,41.7,0.0047806,-0.131175,45.1,1.8174085763341632,11.673388469172759,1.6876366909758283e-11,0.19090780574189858,166.2613546720686,5.678611299004972,-0.334,N,2025.7.3,6/23/2025,4.0,bootstrapping +LONGi Green Energy Technology Co Ltd LR4-72HPH-460M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,460.0,431.1,2.12,,,72.0,11.73,49.7,10.98,41.9,0.0048093,-0.13170500000000002,45.1,1.7913648708091157,11.730004995613644,1.0474603986585343e-11,0.1938141252922558,455089.61334853934,1.5202229243488328,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR4-72HPH-465M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,465.0,435.9,2.12,,,72.0,11.79,49.9,11.05,42.1,0.0048338999999999995,-0.13223500000000002,45.1,1.8000361033593033,11.790004903081556,1.0768204816907998e-11,0.19016636727830094,457278.47423354373,1.706749649710694,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-66HBD-475M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,475.0,442.0,2.29,,,66.0,13.50866742,44.8,12.62590725,37.63,0.005673640316400001,-0.11424,47.67,1.6176710344941374,13.527679451476477,1.2338580448061369e-11,0.16365755527500592,116.2840222321443,5.812304249128341,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-66HBD-480M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,480.0,446.8,2.29,,,66.0,13.58799822,44.95,12.70513499,37.78,0.0057069592524,-0.1146225,47.67,1.6232865877622233,13.606581298434199,1.2458434062772306e-11,0.16112307672302292,117.8136385335252,5.843644123652848,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-66HBD-485M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,485.0,451.6,2.29,,,66.0,13.67,45.1,12.79,37.93,0.005741400000000001,-0.11500500000000001,47.67,1.6287092437247417,13.687973871317757,1.2543549881308546e-11,0.15861357606799814,120.63331034055399,5.847882977717437,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-66HBD-490M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,490.0,456.4,2.29,,,66.0,13.74414082,45.25,12.86764706,38.08,0.005772539144400001,-0.1153875,47.67,1.6341257231715487,13.761499315423533,1.2620293277712617e-11,0.15622695279133858,123.69765883281703,5.85122615847177,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-66HBD-495M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,495.0,461.2,2.29,,,66.0,13.82097165,45.4,12.94794664,38.23,0.005804808093,-0.11577000000000001,47.67,1.6395360666785284,13.837722757367619,1.269834101220375e-11,0.15383962260122672,126.92970211982748,5.853688121440676,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-520M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,520.0,484.3,2.49,,,72.0,13.57102465,48.9,12.66747868,41.05,0.0055641201065,-0.126651,47.34,1.7699763280196732,13.591250993376994,1.3231159758339082e-11,0.179176713945148,120.22002993829437,4.741856600552326,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-525M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,525.0,489.1,2.49,,,72.0,13.65,49.05,12.75,41.2,0.005596500000000001,-0.1270395,47.34,1.7753271435077222,13.66957349632042,1.3301988253635877e-11,0.17659677300154028,123.15357043788734,4.735121456998045,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-530M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,530.0,493.9,2.49,,,72.0,13.71266424,49.2,12.81741233,41.35,0.0056221923384000005,-0.127428,47.34,1.7806720016068731,13.731566310550495,1.3355762937737306e-11,0.17425731994156451,126.41642193176477,4.727668335530419,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-535M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,535.0,498.7,2.49,,,72.0,13.78,49.35,12.9,41.5,0.005649800000000001,-0.12781650000000003,47.34,1.7852894424960146,13.797593316374508,1.3276915854190563e-11,0.1719762678785238,134.7007537294141,4.629028240080671,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-535M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,535.0,494.2,2.49,,,72.0,13.78241165,49.35,12.89556627,41.5,0.005237316427,-0.139167,46.6,1.8983463385040464,13.796651940477538,6.903272050209394e-11,0.1523574270223408,147.45856479433755,9.7780010879194,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-540M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,540.0,497.4,2.51,,,72.0,13.85,49.5,12.97,41.65,0.0062325,-0.13167,48.68,1.8666663996211716,13.864698703455849,4.118149237048528e-11,0.15644668785376842,147.41345353043462,11.535745549138433,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-540M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,540.0,499.0,2.49,,,72.0,13.84716319,49.5,12.96518607,41.65,0.0052619220122,-0.13959,46.6,1.904008213392498,13.860815977227379,6.930798631405438e-11,0.1500873872687839,152.22419646148288,9.768925250266351,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-545M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,545.0,502.2,2.51,,,72.0,13.92,49.65,13.04,41.8,0.006264,-0.13206900000000002,48.68,1.8725512144970877,13.934355721504126,4.153812993545485e-11,0.15407970511622798,149.40311167475724,11.566752163043612,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-545M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,545.0,503.8,2.49,,,72.0,13.91549272,49.65,13.03827751,41.8,0.0052878872336,-0.140013,46.6,1.9096635048678923,13.928567829437597,6.959529139087744e-11,0.14780446258293348,157.30437388609954,9.759141153894031,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-550M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,550.0,506.9,2.51,,,72.0,13.99,49.8,13.12,41.95,0.0062955,-0.132468,48.68,1.8777185274930999,14.003480852746671,4.1510808152480595e-11,0.15184639368482575,157.5813564097082,11.510896786659757,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-550M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,550.0,508.6,2.49,,,72.0,13.98313251,49.8,13.12,41.95,0.0053135903538000006,-0.14043599999999998,46.6,1.91462434417145,13.995164133462215,6.928063500739974e-11,0.145664621638692,169.29117867732802,9.6703224673938,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-555M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,555.0,511.7,2.51,,,72.0,14.05,49.95,13.19,42.1,0.0063225,-0.132867,48.68,1.8829356045534207,14.062649488950214,4.148074626456156e-11,0.14973836875678714,166.31692439732495,11.461351154138681,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-555M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,555.0,513.3,2.49,,,72.0,14.04029954,49.95,13.19,42.1,0.0053353138252,-0.140859,46.6,1.9197350278174692,14.051400324534669,6.904550353466237e-11,0.1436333274090499,181.66778733284576,9.599026052269616,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-560M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,560.0,516.5,2.51,,,72.0,14.1,50.1,13.26,42.25,0.006344999999999999,-0.133266,48.68,1.8874887108906653,14.11133586341066,4.1070950490133715e-11,0.1478578071590652,183.91145109942465,11.332340872060653,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-560M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,560.0,518.1,2.49,,,72.0,14.0989617,50.1,13.25543787,42.25,0.0053576054460000005,-0.141282,46.6,1.9252953680800382,14.109454915886081,6.920248822148511e-11,0.1415358028393399,190.17124129155673,9.579045702663821,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HBD-565M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,565.0,521.2,2.51,,,72.0,14.16,50.25,13.33,42.4,0.006372,-0.13366500000000003,48.68,1.8927160392384146,14.170548898742622,4.104838559408472e-11,0.14579014113008087,195.69705474599152,11.28480942676759,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-565M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,565.0,522.9,2.49,,,72.0,14.16,50.3,13.32,42.42,0.0053808,-0.141846,46.6,1.9324796661746593,14.170171327665736,6.907799095107194e-11,0.14145759718279036,196.93000215135555,9.522667681455061,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-72HPH-570M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,0,570.0,527.7,2.49,,,72.0,14.22,50.5,13.39,42.58,0.005403600000000001,-0.14240999999999998,46.6,1.9389516292612161,14.229574056944484,6.833418391388809e-11,0.1423263506689931,211.39217658052863,9.385379923017348,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-575M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,575.0,543.0,2.72,,,78.0,13.72,53.3,12.84,44.78,0.004390400000000001,-0.125788,44.01,1.8703184371480537,13.740008500972122,5.611803201923158e-12,0.20037000171714392,137.3954192409732,7.26050975932781,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-580M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,580.0,547.8,2.72,,,78.0,13.78,53.45,12.91,44.94,0.0044096000000000005,-0.126142,44.01,1.8753200411964064,13.798934139451145,5.620635672729991e-12,0.1971589991948415,143.48954283504617,7.231113449268015,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-585M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,585.0,552.6,2.72,,,78.0,13.84,53.6,12.98,45.1,0.0044288,-0.126496,44.01,1.8803254657599968,13.857886508717241,5.629752333597287e-12,0.19398173057985743,150.0967683798138,7.202347388064787,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-590M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,590.0,557.5,2.72,,,78.0,13.89,53.75,13.04,45.25,0.0044448,-0.12685,44.01,1.8851769406390224,13.906958672563963,5.621468808499503e-12,0.19184342385570352,157.12934798689025,7.153075825574395,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-595M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,595.0,562.3,2.72,,,78.0,13.96,53.9,13.11,45.39,0.0044672,-0.127204,44.01,1.8904228767273323,13.97668419014573,5.65052784528344e-12,0.19025439354600443,159.1897068959913,7.1527477955283665,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-600M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,600.0,567.2,2.72,,,78.0,14.03,54.05,13.18,45.53,0.004489600000000001,-0.12755799999999998,44.01,1.8956700758623586,14.04641264478351,5.679687743459609e-12,0.18868188352276039,161.2906916300793,7.152578435134521,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LONGi Green Energy Technology Co Ltd LR5-78HBD-605M,LONGi Green Energy Technology Co Ltd,Mono-c-Si,1,605.0,572.0,2.72,,,78.0,14.09,54.2,13.25,45.67,0.0045088,-0.127912,44.01,1.9002913257789833,14.105553433299335,5.656156474612851e-12,0.1873285865071428,169.70271039046256,7.0737752191012655,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +LUMA Resources LRSS,LUMA Resources,Mono-c-Si,0,80.0,72.0,0.5,1.321,0.33885,16.0,9.89,10.43,9.34,8.56,0.0040549,-0.027952400000000002,50.61,0.3958145914672227,9.897073629864034,3.5228866330209365e-11,0.07099846612961937,99.26655205867726,12.322642184895296,-0.378,Y,2025.7.3,6/23/2025,4.0,first_pass +Luma Resources LLC LRSS28-95A,Luma Resources LLC,Mono-c-Si,0,95.0,94.0,0.58,,,28.0,12.93,9.54,12.31,7.72,0.0045255,-0.0247086,55.78,0.29366607354019036,12.941460604174086,9.989998182381134e-14,0.07161264789795507,80.79430398597526,-30.2785074199577,-0.0345,Y,2025.7.3,6/23/2025,2.0,first_pass +Luma Resources LLC LRSS28-100A,Luma Resources LLC,Mono-c-Si,0,100.0,98.9,0.58,,,28.0,13.35,9.73,12.82,7.8,0.0046725000000000004,-0.025200700000000003,55.78,0.29914417321281306,13.350001005027602,9.990000115989298e-14,0.07526042566318576,999702.3524297227,-30.501363394527992,-0.0345,Y,2025.7.3,6/23/2025,2.0,first_pass +Lumos S32-175-50-IM,Lumos,Mono-c-Si,1,175.0,161.1,1.93,,,32.0,11.1,21.6,10.5,17.13,0.0033522,-0.07002720000000001,43.5,0.7936345060944454,11.106254118132412,1.6717494421733976e-11,0.19923430787843438,353.6071520746581,-13.352351475597448,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S32-180-50-IM,Lumos,Mono-c-Si,1,180.0,165.8,1.93,,,32.0,11.2,21.7,10.7,17.26,0.0033824,-0.0703514,43.5,0.798722620764183,11.200002048375035,1.7788509824057123e-11,0.18286884668172898,999985.0412104508,-12.994138485333536,-0.3696,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos S32-185-50-IM,Lumos,Mono-c-Si,1,185.0,170.5,1.93,,,32.0,11.3,21.8,10.8,17.59,0.0034126000000000004,-0.07067559999999999,43.5,0.8075479394271933,11.300001770623048,2.1338665176174713e-11,0.1566739932942544,999977.6595913528,-11.768714979945194,-0.3696,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos S32-190-50-IM,Lumos,Mono-c-Si,1,190.0,175.1,1.93,,,32.0,11.4,21.9,10.9,17.7,0.0034428,-0.0709998,43.5,0.8119813370306901,11.400001737472662,2.205566425702832e-11,0.15239464363622834,999995.1809878194,-11.595845781910795,-0.3696,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos L40-225-47-xx,Lumos,Mono-c-Si,0,225.0,207.4,2.28,,,40.0,11.1,27.1,10.45,21.94,0.0033522,-0.0878582,43.5,1.0088111004307612,11.11270954198547,2.361270323046311e-11,0.20054789881119084,175.15042735599698,-10.876291482255999,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L40-230-47-xx,Lumos,Mono-c-Si,0,230.0,212.1,2.28,,,40.0,11.2,27.2,10.6,22.04,0.0033824,-0.08818240000000001,43.5,1.0104185748535375,11.206667948802316,2.2660949711897747e-11,0.19731852667588437,331.43139273340347,-11.254738565372897,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L40-235-47-xx,Lumos,Mono-c-Si,0,235.0,216.7,2.28,,,40.0,11.3,27.3,10.7,22.14,0.0034126000000000004,-0.0885066,43.5,1.0143446362281083,11.306163213382895,2.30032634564859e-11,0.19423063933989798,356.11395409369857,-11.212519088845838,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX 72/48,Lumos,Mono-c-Si,1,240.0,221.3,2.01,,,12.0,9.99,31.71,9.32,25.75,0.0035964,-0.0891051,43.38,1.2060682520689947,10.009289018726685,3.724080490655411e-11,0.24691938429826052,127.8823311931341,7.601657877806477,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L40-240-47-xx,Lumos,Mono-c-Si,0,240.0,221.4,2.28,,,40.0,11.4,27.4,10.8,22.25,0.0034428,-0.08883079999999999,43.5,1.018511818112791,11.405681854465874,2.3495764680161214e-11,0.19012804994035176,381.47049483551314,-11.125136240500263,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX260-60M,Lumos,Multi-c-Si,0,260.0,232.9,1.63777,1.646,0.995,60.0,8.8,37.8,8.5,30.6,0.004728240000000001,-0.1347192,46.0,1.6368655274646726,8.800155384559122,8.226112405695474e-10,0.19469506484806648,11026.406427192414,9.540385260498434,-0.4796,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos GSX270-60M,Lumos,Multi-c-Si,0,270.0,247.3,1.6268799999999999,1.64,0.992,60.0,9.07,38.45,8.69,31.06,0.003628,-0.11535000000000001,44.58,1.5232515114998433,9.07000267005369,9.888261158209707e-11,0.2942785696242183,999821.775638847,9.70493549427072,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos S48-270-29-IM,Lumos,Mono-c-Si,1,270.0,250.2,1.93,,,48.0,11.1,32.5,10.48,26.23,0.0033522,-0.105365,43.5,1.2061834266544955,11.10943428754736,2.185233385226315e-11,0.24949645955685268,293.5474188686822,-11.443283823733454,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX275-60M,Lumos,Multi-c-Si,0,275.0,252.0,1.6268799999999999,1.64,0.992,60.0,9.2,38.77,8.79,31.29,0.00368,-0.11631000000000001,44.58,1.533383539883375,9.20000283675464,9.618428321839612e-11,0.30828640076092995,999998.4510759347,9.335898059512848,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos S48-275-29-IM,Lumos,Mono-c-Si,1,275.0,255.0,1.93,,,48.0,11.2,32.6,10.58,26.4,0.0033824,-0.1056892,43.5,1.211739388378673,11.208857906463287,2.297826078565409e-11,0.23823525381521082,301.2263574383568,-11.148444114145292,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX280-60M,Lumos,Multi-c-Si,0,280.0,256.7,1.6268799999999999,1.64,0.992,60.0,9.34,39.1,8.88,31.53,0.0037359999999999997,-0.1173,44.58,1.5424590337478223,9.34000307795881,9.148636900621157e-11,0.32948322310498646,999999.8580004738,8.764250947263442,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos LSX280-60M-C,Lumos,Multi-c-Si,0,280.0,256.7,1.6268799999999999,1.64,0.992,60.0,9.34,39.1,8.88,31.53,0.0037359999999999997,-0.1173,44.58,1.5424590337478223,9.34000307795881,9.148636900621157e-11,0.32948322310498646,999999.8580004738,8.764250947263442,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos S48-280-29-IM,Lumos,Mono-c-Si,1,280.0,259.7,1.93,,,48.0,11.3,32.7,10.68,26.5,0.0034126000000000004,-0.1060134,43.5,1.2156110156455,11.308325086530964,2.327529358113472e-11,0.23477832710080754,318.6747843075562,-11.121696423193297,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX285-60M,Lumos,Multi-c-Si,0,285.0,261.4,1.6268799999999999,1.64,0.992,60.0,9.48,39.43,8.97,31.76,0.0037920000000000007,-0.11828999999999999,44.58,1.5551320082061078,9.482588698803452,9.205381342631495e-11,0.3400815565507167,1245.4032702136212,8.698895849907192,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos LSX285-60M-C,Lumos,Multi-c-Si,0,285.0,261.4,1.6268799999999999,1.64,0.992,60.0,9.48,39.43,8.97,31.76,0.0037920000000000007,-0.11828999999999999,44.58,1.5551320082061078,9.482588698803452,9.205381342631495e-11,0.3400815565507167,1245.4032702136212,8.698895849907192,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S48-285-29-IM,Lumos,Mono-c-Si,1,285.0,264.4,1.93,,,48.0,11.4,32.8,10.78,26.6,0.0034428,-0.10633759999999998,43.5,1.2194856993449419,11.407802325530577,2.3575151524390707e-11,0.2313846522633726,338.07678067792415,-11.094661773247907,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX290-60M,Lumos,Multi-c-Si,0,290.0,266.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.77,9.06,32.0,0.003848,-0.11931000000000001,44.58,1.5712623604212808,9.627340405234149,9.707870375162008e-11,0.342447118018945,448.7956020514584,9.054593276658517,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos LSX290-60M-C,Lumos,Multi-c-Si,0,290.0,266.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.77,9.06,32.0,0.003848,-0.11931000000000001,44.58,1.5712623604212808,9.627340405234149,9.707870375162008e-11,0.342447118018945,448.7956020514584,9.054593276658517,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S48-290-29-IM,Lumos,Mono-c-Si,1,290.0,269.1,1.93,,,48.0,11.5,32.9,10.88,26.8,0.0034730000000000004,-0.1066618,43.5,1.225760997020007,11.507292972538396,2.5157567357078223e-11,0.217416324163784,342.83521177731325,-10.690575786690655,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX295-60M,Lumos,Multi-c-Si,0,295.0,270.4,1.6268799999999999,1.64,0.992,60.0,9.77,40.11,9.15,32.24,0.0041034,-0.1131102,46.67,1.530069215334997,9.785671253536337,3.960261725042655e-11,0.35782532897941155,223.0806574585144,7.8432896838665584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos LSX295-60M-C,Lumos,Multi-c-Si,0,295.0,270.4,1.6268799999999999,1.64,0.992,60.0,9.77,40.11,9.15,32.24,0.0041034,-0.1131102,46.67,1.530069215334997,9.785671253536337,3.960261725042655e-11,0.35782532897941155,223.0806574585144,7.8432896838665584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX300-60M,Lumos,Multi-c-Si,0,300.0,275.1,1.6268799999999999,1.64,0.992,60.0,9.91,40.45,9.24,32.48,0.0041622000000000004,-0.11406899999999999,46.67,1.5455351056335254,9.930945213767378,4.169229983689515e-11,0.3601251937774448,170.3893201772202,8.18489238767737,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos LSX300-60M-C,Lumos,Multi-c-Si,0,300.0,275.1,1.6268799999999999,1.64,0.992,60.0,9.91,40.45,9.24,32.48,0.0041622000000000004,-0.11406899999999999,46.67,1.5455351056335254,9.930945213767378,4.169229983689515e-11,0.3601251937774448,170.3893201772202,8.18489238767737,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX305-60M,Lumos,Multi-c-Si,0,305.0,279.8,1.6268799999999999,1.64,0.992,60.0,10.061831783469275,40.791992844343525,9.319077416024621,32.72856167881353,0.004225969349057096,-0.11503341982104874,46.67,1.5630767855278895,10.09084521074077,4.5268101294795724e-11,0.36118505919228383,125.25867191411358,8.798278225543383,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos LSX305-60M-C,Lumos,Multi-c-Si,0,305.0,279.8,1.6268799999999999,1.64,0.992,60.0,10.061831783469275,40.791992844343525,9.319077416024621,32.72856167881353,0.004225969349057096,-0.11503341982104874,46.67,1.5630767855278895,10.09084521074077,4.5268101294795724e-11,0.36118505919228383,125.25867191411358,8.798278225543383,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX340-72M,Lumos,Multi-c-Si,0,340.0,311.8,1.9403519999999999,1.956,0.992,72.0,9.64,47.18,8.96,38.32,0.0038560000000000005,-0.14154,44.58,1.8862342479091858,9.65897249593961,1.2888739033426714e-10,0.3586593911534742,182.23625738273012,11.608569810026566,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L60-340-21-xx,Lumos,Mono-c-Si,1,340.0,315.5,2.28,,,60.0,11.1,40.7,10.48,32.64,0.0033522,-0.1319494,43.5,1.5054937824689572,11.109423745035565,1.998896364159329e-11,0.3354612002178912,395.1315951745486,-12.080682107585915,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S60-340-13-IM,Lumos,Mono-c-Si,1,340.0,316.6,1.93,,,60.0,11.1,40.7,10.48,32.64,0.0033522,-0.1319494,43.5,1.5054937824689572,11.109423745035565,1.998896364159329e-11,0.3354612002178912,395.1315951745486,-12.080682107585915,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX345-72M,Lumos,Multi-c-Si,0,345.0,315.8,1.9403519999999999,1.956,0.992,72.0,9.72,47.28,8.98,38.4,0.0038880000000000004,-0.14184,44.6,1.9163111001523923,9.743741252569448,1.814428788835286e-10,0.35147468608065724,143.89864584178102,14.666712116471313,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L60-345-21-xx,Lumos,Mono-c-Si,1,345.0,320.2,2.28,,,60.0,11.2,40.8,10.58,32.74,0.0033824,-0.1322736,43.5,1.5092936604354987,11.2088245702192,2.0216709987972364e-11,0.3310762512876912,420.1965663126601,-12.065576069044736,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S60-345-13-IM,Lumos,Mono-c-Si,1,345.0,321.4,1.93,,,60.0,11.2,40.8,10.58,32.74,0.0033824,-0.1322736,43.5,1.5092936604354987,11.2088245702192,2.0216709987972364e-11,0.3310762512876912,420.1965663126601,-12.065576069044736,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX350-72M,Lumos,Multi-c-Si,0,350.0,320.5,1.9403519999999999,1.956,0.992,72.0,9.81,47.37,9.1,38.48,0.003924,-0.14211,44.6,1.916039192933934,9.83034389103705,1.749519876467694e-10,0.34834172972999017,167.97339838274996,14.229995839445955,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L60-350-21-xx,Lumos,Mono-c-Si,1,350.0,324.9,2.28,,,60.0,11.3,40.9,10.68,32.84,0.0034126000000000004,-0.1325978,43.5,1.5130980687403743,11.308234571259376,2.044666670779293e-11,0.32677197508037376,448.41717565234273,-12.050006809483719,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S60-350-13-IM,Lumos,Mono-c-Si,1,350.0,326.1,1.93,,,60.0,11.3,40.9,10.68,32.84,0.0034126000000000004,-0.1325978,43.5,1.5130980687403743,11.308234571259376,2.044666670779293e-11,0.32677197508037376,448.41717565234273,-12.050006809483719,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX355-72M,Lumos,Multi-c-Si,0,355.0,325.5,1.9403519999999999,1.956,0.992,72.0,9.898520572643996,47.465658561456,9.208248308672879,38.552392170576006,0.004157378640510479,-0.13385315714330592,46.67,1.826812329847677,9.919665167918762,5.012715363806859e-11,0.3675994143669868,172.08607556276885,9.82881105488008,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L60-355-21-xx,Lumos,Mono-c-Si,1,355.0,329.7,2.28,,,60.0,11.4,41.0,10.78,32.94,0.0034428,-0.132922,43.5,1.516906866660831,11.407653565390044,2.067882354747005e-11,0.3225461710077028,480.43312732103044,-12.033991860353526,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos S60-355-13-IM,Lumos,Mono-c-Si,1,355.0,330.9,1.93,,,60.0,11.4,41.0,10.78,32.94,0.0034428,-0.132922,43.5,1.516906866660831,11.407653565390044,2.067882354747005e-11,0.3225461710077028,480.43312732103044,-12.033991860353526,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX 72/72,Lumos,Mono-c-Si,1,360.0,334.9,2.01,,,12.0,9.99,47.6,9.32,38.6,0.0044955,-0.13280400000000003,43.8,1.8002714965361144,10.009857766883052,3.210148101908269e-11,0.3793532655496871,190.84417617017118,6.96956811243214,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX360-72M,Lumos,Multi-c-Si,0,360.0,330.2,1.9403519999999999,1.956,0.992,72.0,9.98760725779779,47.56058987857892,9.319303340142914,38.62949695491716,0.004194795048275073,-0.13412086345759253,46.67,1.8277007997887391,10.006039406257855,4.8803593152253205e-11,0.36511524095647263,197.84062209165737,9.500579182678859,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos GSX365-72M,Lumos,Multi-c-Si,0,365.0,334.9,1.9403519999999999,1.956,0.992,72.0,10.07749572311797,47.655711058336074,9.429878352051906,38.706755948826995,0.0042325482037095475,-0.13438910518450772,46.67,1.8287844251569434,10.09334347862091,4.7633095976526984e-11,0.36263054169784914,230.594660699916,9.195862771756783,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L72-410-08-xx,Lumos,Mono-c-Si,1,410.0,382.0,2.28,,,72.0,10.9,48.8,10.38,39.6,0.0032918,-0.15820959999999998,43.5,1.8093514856460335,10.900005975209341,2.1089768882108252e-11,0.35702623889042195,651306.098529049,-11.595337947372883,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L72-415-08-xx,Lumos,Mono-c-Si,1,415.0,386.7,2.28,,,72.0,11.0,48.9,10.48,39.7,0.0033220000000000003,-0.1585338,43.5,1.8138000777510965,11.000006027983048,2.151902959727361e-11,0.35228566377188136,642876.000950181,-11.516658864817947,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L72-420-08-xx,Lumos,Mono-c-Si,1,420.0,391.5,2.28,,,72.0,11.1,49.0,10.58,39.8,0.0033522,-0.158858,43.5,1.8182438303093755,11.10000607849015,2.195245463246469e-11,0.3476346574210233,634836.4528311719,-11.438813570330005,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L72-425-08-xx,Lumos,Mono-c-Si,1,425.0,396.3,2.28,,,72.0,11.2,49.1,10.68,39.85,0.0033824,-0.1591822,43.5,1.8216881253248305,11.200006200324806,2.2063100409062832e-11,0.3484486104965707,629439.4212884549,-11.466989129386995,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Lumos L72-430-08-xx,Lumos,Mono-c-Si,1,430.0,401.0,2.28,,,72.0,11.3,49.2,10.78,39.9,0.0034126000000000004,-0.15950640000000002,43.5,1.8250932654033614,11.3000038586198,2.216009980905486e-11,0.34145639934206506,999999.7579108782,-11.49917306547244,-0.3696,N,2025.7.3,6/23/2025,2.0,first_pass +Lumos L72-435-08-xx,Lumos,Mono-c-Si,1,435.0,405.8,2.28,,,72.0,11.4,49.3,10.88,40.05,0.0034428,-0.1598306,43.5,1.830551832360965,11.400006292831542,2.293945824627076e-11,0.33947289070590386,615000.3641982954,-11.314953633163656,-0.3696,N,2025.7.3,6/23/2025,4.0,first_pass +Luxco LXP-3J240W,Luxco,Multi-c-Si,0,240.0,217.8,1.617035,1.645,0.983,60.0,8.43,37.5,8.0,30.0,0.004215,-0.12,45.4,1.507077613852648,8.43000317823374,1.316596359110121e-10,0.37689874590302397,999999.911758509,5.707789485864737,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Luxco LXP-3J245W,Luxco,Multi-c-Si,0,245.0,222.4,1.617035,1.645,0.983,60.0,8.58,37.6,8.14,30.1,0.00429,-0.12032,45.4,1.5100599174372646,8.594633893430117,1.3195758717430553e-10,0.37607187269620573,999999.9786050373,5.563483203290905,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Luxco LXP-3J250W,Luxco,Multi-c-Si,0,250.0,227.1,1.617035,1.645,0.983,60.0,8.73,37.7,8.28,30.2,0.004365,-0.12064000000000002,45.4,1.51460385096897,8.74187742823342,1.353879985698362e-10,0.3678843776206888,999999.9237791249,5.637083272415595,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Luxco LXP-3J255W,Luxco,Multi-c-Si,0,255.0,231.8,1.617035,1.645,0.983,60.0,8.89,37.8,8.42,30.3,0.004445,-0.12096,45.4,1.5192913197583946,8.890099344558566,1.3918531949930339e-10,0.35991883513078593,32208.070251781704,5.7290737268717455,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Luxco LXP-3J260W,Luxco,Multi-c-Si,0,260.0,236.4,1.617035,1.645,0.983,60.0,9.03,37.9,8.56,30.4,0.004515,-0.12128,45.4,1.5236898738786382,9.03632074775676,1.4237165351279414e-10,0.352314057044367,999999.9243518019,5.782877303237319,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Luxco LXP-3L285W,Luxco,Multi-c-Si,0,285.0,259.5,1.9404,1.96,0.99,72.0,8.38,44.8,7.92,36.0,0.004190000000000001,-0.14336,44.7,1.8050451504437408,8.382209109177174,1.3901713935349565e-10,0.4394059869246628,1666.8364457713053,6.232089589254736,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Luxco LXP-3L290W,Luxco,Multi-c-Si,0,290.0,264.1,1.9404,1.96,0.99,72.0,8.49,44.9,8.03,36.1,0.0042450000000000005,-0.14368,44.7,1.808938489821016,8.491598939560735,1.406961873168007e-10,0.43180266766030384,2292.7737888986594,6.220603942884627,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Luxco LXP-3L295W,Luxco,Multi-c-Si,0,295.0,268.8,1.9404,1.96,0.99,72.0,8.63,45.0,8.15,36.2,0.004315000000000001,-0.14400000000000002,44.7,1.8149023789914565,8.633032029366952,1.465776437887994e-10,0.42292703160817674,1203.7682843931148,6.437225854294156,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Luxco LXP-3L300W,Luxco,Multi-c-Si,0,300.0,273.5,1.9404,1.96,0.99,72.0,8.75,45.1,8.27,36.3,0.004375,-0.14432,44.7,1.8187411698532159,8.752368894404556,1.4835518451678903e-10,0.41527749748022746,1533.9136883275244,6.419340946401048,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Luxor Solar LX-265M/156-60+,Luxor Solar,Mono-c-Si,0,265.0,236.6,1.6236,1.64,0.99,60.0,8.83,38.1,8.59,30.9,0.00458277,-0.12854939999999998,47.1,1.635689361452769,8.830001339981825,6.760321412499437e-10,0.15165220900001045,999990.7652272753,13.914587961265763,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-270M/156-60+,Luxor Solar,Mono-c-Si,0,270.0,241.2,1.6236,1.64,0.99,60.0,8.89,38.2,8.71,31.0,0.004613910000000001,-0.12888680000000002,47.1,1.6461223148647173,8.890000796886625,7.424028205890619e-10,0.08958650246280676,999999.9023147329,14.718636097930279,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-275M/156-60+,Luxor Solar,Mono-c-Si,0,275.0,245.8,1.6236,1.64,0.99,60.0,8.95,38.3,8.85,31.1,0.0046450499999999995,-0.12922419999999998,47.1,1.6582872430430395,8.95001291887549,8.342219275189756e-10,0.10775320224193095,74653.50958817614,15.744464859293208,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-280M/156-60+,Luxor Solar,Mono-c-Si,0,280.0,250.4,1.6236,1.64,0.99,60.0,9.23,38.4,8.96,31.2,0.00479037,-0.1295616,47.1,1.6483163381417532,9.230001420846055,7.041399376214748e-10,0.15382872141924683,999994.1772162333,13.881699679535277,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-280P/156-72+,Luxor Solar,Multi-c-Si,0,280.0,250.8,1.9403519999999999,1.956,0.992,72.0,8.56,44.0,7.83,35.8,0.00501616,-0.143528,46.3,1.8888199900445304,8.584250926535443,6.275080890206785e-10,0.3356534171006134,118.47768010656496,17.4991029172069,-0.4609,N,2025.7.3,6/23/2025,4.0,first_pass +Luxor Solar LX-285M/156-60+,Luxor Solar,Mono-c-Si,0,285.0,255.1,1.6236,1.64,0.99,60.0,9.37,38.5,9.12,31.3,0.00486303,-0.129899,47.1,1.6551944235749423,9.37000123545704,7.413129506047603e-10,0.1317646571114404,999999.8531451428,14.217656588229843,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-320M/156-72+,Luxor Solar,Mono-c-Si,0,320.0,290.6,1.9404,1.96,0.99,72.0,8.9,46.2,8.58,37.3,0.0056960000000000005,-0.1535688,45.2,1.9330919712237347,8.900182866115077,3.713648007411969e-10,0.2862482026302683,13931.62264552455,9.965016839785719,-0.4432,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-325M/156-72+,Luxor Solar,Mono-c-Si,0,325.0,291.3,1.9404,1.96,0.99,72.0,9.15,46.0,8.76,37.1,0.004968450000000001,-0.1679,46.2,1.9797544782455436,9.150002773387747,7.421607416992349e-10,0.30285145555700915,999989.054543961,5.712705686610446,-0.4781,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-330M/156-72+,Luxor Solar,Mono-c-Si,0,330.0,296.0,1.9404,1.96,0.99,72.0,9.19,46.1,8.85,37.3,0.0049901699999999995,-0.168265,46.2,1.9940372273490783,9.190317914616221,8.367670773894033e-10,0.24818952975606404,7174.424963462382,6.709407991846708,-0.4781,N,2025.7.3,6/23/2025,2.0,first_pass +Luxor Solar LX-335M/156-72+,Luxor Solar,Mono-c-Si,0,335.0,300.6,1.9404,1.96,0.99,72.0,9.23,46.15,8.96,37.4,0.005011890000000001,-0.1684475,46.2,2.0045413322491727,9.230001721694808,9.258870662026439e-10,0.18639604621043757,999999.9468616074,7.548459015915774,-0.4781,N,2025.7.3,6/23/2025,2.0,first_pass +Magnus green solar LLC MGS-425W-M54HN-M10,Magnus green solar LLC,Mono-c-Si,0,425.0,396.8,2.21,,,72.0,11.29,50.0,10.3,41.3,0.0066611,-0.1545,43.9,1.947838072180516,11.325783558059355,7.625433214731686e-11,0.2635942082633814,83.16609067324951,2.3887684539664997,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-430W-M54HN-M10,Magnus green solar LLC,Mono-c-Si,0,430.0,401.6,2.21,,,72.0,11.3,50.2,10.36,41.5,0.006667,-0.155118,43.9,1.95132551356962,11.33145776547109,7.25396724469454e-11,0.261198977750317,93.82575103397446,1.9526425446883495,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-440W-M54HN-M10,Magnus green solar LLC,Mono-c-Si,0,440.0,411.1,2.21,,,72.0,11.34,50.5,10.52,41.8,0.0066906,-0.156045,43.9,1.9520242199150444,11.361720262169944,6.388532777027273e-11,0.257648918345587,134.51673561637944,0.8420189793930726,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-60-M10-440,Magnus green solar LLC,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.0,13.05,33.7,0.0075515,-0.12546000000000002,43.7,1.5453777111616855,13.732707358977587,4.1144527691424915e-11,0.19786257969884802,1003.4330283273594,-3.2657099796228066,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-445W-M54HN-M10,Magnus green solar LLC,Mono-c-Si,0,445.0,415.9,2.21,,,72.0,11.37,50.6,10.61,42.0,0.0067082999999999995,-0.156354,43.9,1.9528712541287412,11.386383180458592,6.195643505119248e-11,0.24538284342815417,170.2967851881052,0.5511523125672938,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-445W-M72HBI,Magnus green solar LLC,Mono-c-Si,1,445.0,416.2,2.21,,,72.0,11.37,50.6,10.61,42.0,0.005002799999999999,-0.14926999999999999,43.8,1.9149218099039778,11.387552144281491,3.704097210525106e-11,0.25322636073360627,164.03601155311625,1.269640433926775,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-60-M10-450,Magnus green solar LLC,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.2,13.27,33.9,0.007617500000000001,-0.12607200000000002,43.7,1.551419129805903,13.927282806577212,4.079302308474387e-11,0.1930644441071485,103019.36501174951,-3.4490736509583555,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-540W-M72HBI,Magnus green solar LLC,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.4,13.27,40.7,0.007617500000000001,-0.151164,43.7,1.8660492731505065,13.850006032051267,4.409111811336126e-11,0.22695659972892146,521124.511300321,-2.7998412787542706,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Magnus green solar LLC MGS-545W-M72HBI,Magnus green solar LLC,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.5,13.36,40.8,0.007667,-0.15147,43.7,1.8709064120152301,13.94000287096342,4.5060964733983076e-11,0.20593919078069292,999997.5209174477,-2.6795791376416203,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605PUL-260,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,260.0,235.5,1.63,,,60.0,8.72,38.53,8.39,31.05,0.008388640000000001,-0.15939861000000002,45.8,1.6748572195289382,8.720186204486177,8.900843671368487e-10,0.23628272298660985,11065.303548826916,-5.524152152204007,-0.4369,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605PUL-265,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,265.0,240.2,1.63,,,60.0,8.75,38.72,8.46,31.43,0.0084175,-0.16018464,45.8,1.6934577690284318,8.750001574037451,1.0282453127395228e-09,0.17970865004488643,999999.2704013404,-4.432243915439568,-0.4369,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605PUL-270,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,270.0,242.8,1.63,,,60.0,9.13,38.21,8.63,31.32,0.00501237,-0.1264751,47.4,1.5798349435589538,9.132499636430909,2.8494097446413637e-10,0.2546998423380572,930.2994714908693,7.990234953807949,-0.4387,N,2025.7.3,6/23/2025,4.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605PUL-275,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,275.0,247.5,1.63,,,60.0,9.22,38.45,8.73,31.54,0.00506178,-0.12726950000000004,47.4,1.588993719061664,9.22134635238479,2.849767974217433e-10,0.2508508903795838,1717.861418788002,7.899666324384713,-0.4387,N,2025.7.3,6/23/2025,4.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-290,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Mono-c-Si,0,290.0,264.0,1.63,,,60.0,9.54,39.45,9.03,32.15,0.0046650599999999995,-0.12667395,46.1,1.5887010795543135,9.54223402038502,1.5629289272380353e-10,0.2843515941753495,1214.2749830671767,5.773448851782897,-0.4234,N,2025.7.3,6/23/2025,4.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS605MUL-295,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Mono-c-Si,0,295.0,268.7,1.63,,,60.0,9.59,39.81,9.12,32.38,0.00468951,-0.12782991,46.1,1.601054340930549,9.590002736291863,1.5245556354663795e-10,0.2852551714957433,999999.9755510656,5.507185076119763,-0.4234,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725PUL-310,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,310.0,280.3,1.93,,,72.0,9.56,45.42,8.68,35.8,0.00859444,-0.18785712000000004,46.3,1.9561930908532772,9.605488048594678,7.533954939860261e-10,0.4595475499928232,96.58086746761325,-7.316776167338759,-0.4348,N,2025.7.3,6/23/2025,4.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725PUL-315,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,315.0,286.2,1.93,,,72.0,9.02,45.55,8.8,35.83,0.00460922,-0.14179715,46.7,1.8002464746672016,9.020220328530085,9.257681856187184e-11,0.3425310597404204,14022.809370842913,5.054794052780439,-0.4097,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725PUL-320,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,320.0,290.9,1.93,,,72.0,9.06,45.68,8.93,35.86,0.00462966,-0.14220184,46.7,1.8121246062498368,9.060200122224995,1.0216343068786932e-10,0.3102771698351945,14046.945492965782,5.854526638758001,-0.4097,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725PUL-325,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,325.0,295.5,1.93,,,72.0,9.1,45.82,8.95,36.31,0.0046501,-0.14263766,46.7,1.8241200023949238,9.100143354642382,1.1216770889560491e-10,0.22366765719051804,14198.183652533493,6.616542869669711,-0.4097,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725PUL-330,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Multi-c-Si,0,330.0,300.2,1.93,,,72.0,9.13,45.95,8.97,36.79,0.00466543,-0.14304235,46.7,1.8369942293088892,9.130121690356368,1.2503063057093952e-10,0.18970520500968252,14232.928154005594,7.524740956450545,-0.4097,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725MUL-350,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Mono-c-Si,0,350.0,318.8,1.93,,,72.0,9.53,47.01,9.08,38.58,0.00466017,-0.15094911,46.1,1.9001049574327578,9.530002759767813,1.7152390150040564e-10,0.28952824342774075,999999.9212619689,6.567193059036971,-0.4234,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725MUL-355,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Mono-c-Si,0,355.0,323.5,1.93,,,72.0,9.6,47.31,9.15,38.82,0.0046944,-0.15191241,46.1,1.9124094983030075,9.600002767625012,1.7318389761326957e-10,0.28823535611097306,999999.8389581876,6.587047294285082,-0.4234,N,2025.7.3,6/23/2025,2.0,first_pass +MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS MS725MUL-360,MAR SOLAR PANEL IMALATI VE ELEKTRIK URT DAG PRJ H Z SAN VE T C AS,Mono-c-Si,0,360.0,328.2,1.93,,,72.0,9.66,47.62,9.2,39.14,0.004723740000000001,-0.15290781999999997,46.1,1.9257397942570822,9.660002748302144,1.760646096917822e-10,0.28444430665998216,999999.85472785,6.675216617428184,-0.4234,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS390M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,390.0,362.3,1.96,,,54.0,13.6,37.0,12.85,30.4,0.007616,-0.09620000000000001,46.0,1.3773289330881502,13.610307285945073,2.8992684834154427e-11,0.18474876004213442,243.76767916491443,10.900206467578624,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS395M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,395.0,367.1,1.96,,,54.0,13.67,37.0,12.97,30.5,0.007655200000000001,-0.09620000000000001,46.0,1.3769147969074311,13.675559415966747,2.903941271491973e-11,0.17499814617896722,430.301443163369,10.851734853172779,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS400M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,400.0,371.9,1.96,,,54.0,13.74,37.1,13.09,30.6,0.0076944,-0.09646,46.0,1.377241278124837,13.740005288606765,2.7478886649234125e-11,0.17331047613346343,450278.0032268055,10.28803588324422,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS405M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,405.0,376.7,1.96,,,54.0,13.81,37.2,13.21,30.7,0.0077336,-0.09672000000000001,46.0,1.3836127101456093,13.810002258877917,2.908653025498152e-11,0.163559502385447,999999.4011670519,10.752605443346125,-0.349,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS410M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,410.0,381.5,1.96,,,54.0,13.88,37.3,13.33,30.8,0.007772800000000001,-0.09698,46.0,1.390326019433527,13.880575879279064,3.095728912183907e-11,0.16817597162599604,4053.4242472878245,11.270997158411603,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS415M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,415.0,386.2,1.96,,,54.0,13.95,37.4,13.45,30.9,0.0078119999999999995,-0.09724000000000001,46.0,1.3964621686813834,13.950002287873652,3.260720432923036e-11,0.13766545965038676,839252.7519464223,11.692824013355539,-0.349,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS420M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,420.0,391.0,1.96,,,54.0,14.02,37.4,13.57,31.0,0.0078512,-0.09724000000000001,46.0,1.4007477767395495,14.020001941416636,3.556914103007015e-11,0.116634392067091,842123.3213295002,12.4375826651673,-0.349,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS425M-54HB,Mate Solar Co Ltd,Mono-c-Si,0,425.0,395.8,1.96,,,54.0,14.09,37.5,13.69,31.1,0.0078904,-0.0975,46.0,1.407199473661353,14.090001691595704,3.763029436629099e-11,0.10137134089302725,844199.216856633,12.906666469354079,-0.349,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS435M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,435.0,404.3,2.17,,,72.0,11.23,49.4,10.69,40.7,0.005615000000000001,-0.13436800000000002,46.2,1.8213825736598337,11.231866018831452,1.863415868267932e-11,0.28967539041326107,1743.3129509855075,3.8863792220727067,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS440M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,440.0,409.1,2.17,,,72.0,11.3,49.6,10.76,40.9,0.0056500000000000005,-0.13491200000000003,46.2,1.8292840589439736,11.301631897095204,1.8902821576758032e-11,0.28529101414155994,1975.485249268253,3.9537297081495404,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS445M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,445.0,413.9,2.17,,,72.0,11.37,49.8,10.83,41.1,0.005685,-0.13545600000000002,46.2,1.837185778875411,11.371403942198173,1.91733289304474e-11,0.28096363955783016,2275.4190242760724,4.020561597725543,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS450M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,450.0,418.6,2.17,,,72.0,11.44,50.0,10.9,41.3,0.00572,-0.136,46.2,1.8450877281213045,11.44118205247124,1.9445674383110577e-11,0.27669216379316863,2677.8491068855983,4.086880320968866,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS455M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,455.0,423.4,2.17,,,72.0,11.51,50.2,10.96,41.5,0.005755,-0.136544,46.2,1.8537861064088443,11.511783683050167,1.9929346401350253e-11,0.2724297250635558,1757.972795015433,4.245901956842951,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS460M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,460.0,428.2,2.17,,,72.0,11.58,50.4,11.03,41.7,0.00579,-0.13708800000000002,46.2,1.8616873141104304,11.581562007007062,2.0207008762558357e-11,0.26826371971884133,1988.7836801830917,4.310714661550935,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS465M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,465.0,433.0,2.17,,,72.0,11.65,50.6,11.1,41.9,0.005825,-0.137632,46.2,1.8695891575119614,11.651346227640957,2.0486609851854272e-11,0.26415047360861177,2285.9085043942905,4.375083926486335,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS470M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,470.0,437.8,2.17,,,72.0,11.72,50.8,11.17,42.1,0.005860000000000001,-0.13817600000000002,46.2,1.8774902925650403,11.721136272006557,2.0767745382007187e-11,0.26008925232734026,2682.6730276794624,4.438853362275635,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS520M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,520.0,488.3,2.58,,,72.0,13.54,49.2,12.84,40.5,0.0073116,-0.12792,45.8,1.7372996936147656,13.549033069850978,6.7396927624527545e-12,0.2559409456627924,383.6392807707354,-1.4916476024150949,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS525M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,525.0,493.1,2.58,,,72.0,13.61,49.3,12.94,40.6,0.0073494,-0.12818000000000002,45.8,1.7438662163413259,13.610007248620775,7.180015565118307e-12,0.2526479301308021,474374.2977813291,-1.0512231186599341,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS535M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,535.0,502.8,2.58,,,72.0,13.75,49.5,13.13,40.8,0.007425,-0.1287,45.8,1.743513450578816,13.750884334758483,6.425314596117646e-12,0.24892973933409712,3870.461824429311,-2.0292922009472463,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS540M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,540.0,507.6,2.58,,,72.0,13.82,49.6,13.22,40.9,0.007462800000000001,-0.12896000000000002,45.8,1.7403983147536293,13.820006480688118,5.844984006999396e-12,0.2465556833732262,525780.315212462,3.6552184762481614,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS545M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,545.0,512.4,2.58,,,72.0,13.89,49.7,13.31,40.95,0.0075006,-0.12922000000000003,45.8,1.751713479839792,13.89000332552859,6.619150666436581e-12,0.23941564035829718,999997.6666753994,-1.8744198780921522,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS550M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,550.0,517.2,2.58,,,72.0,13.96,49.8,13.41,41.04,0.0075384,-0.12948,45.8,1.7567589142180873,13.960079980593283,6.8174289778218695e-12,0.24616231599132082,42965.775884549286,-1.676486875721544,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS555M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,555.0,522.0,2.58,,,72.0,14.03,49.9,13.5,41.1,0.0075762,-0.12974,45.8,1.7615716055941353,14.030003497316233,6.995292150148475e-12,0.22435647930835378,900047.9158391353,-1.508953999570958,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS560M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,560.0,526.8,2.58,,,72.0,14.1,50.0,13.59,41.2,0.007613999999999999,-0.13,45.8,1.7657726803811873,14.100006320298125,7.106328663053569e-12,0.2444023770971338,545242.7799148203,-1.4088815231994762,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS565M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,565.0,531.7,2.58,,,72.0,14.17,50.1,13.68,41.3,0.007651799999999999,-0.13026000000000001,45.8,1.771764958620162,14.170003258872333,7.427995837273129e-12,0.2075130949881013,902302.4771396016,-1.1029525476052142,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +Mate Solar Co Ltd MS570M-72HB,Mate Solar Co Ltd,Mono-c-Si,0,570.0,536.5,2.58,,,72.0,14.24,50.2,13.77,41.4,0.0076895999999999996,-0.13052,45.8,1.7757855711433936,14.240165614652458,7.5212882733505e-12,0.23934193501142248,20579.280789545748,-1.0410512056158225,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Mate Solar Co Ltd MS630M-66H,Mate Solar Co Ltd,Mono-c-Si,0,630.0,586.2,3.11,,,66.0,18.23,44.5,17.22,36.6,0.011849500000000002,-0.12727,45.6,1.685750106471647,18.242768162049504,6.194752796294653e-11,0.15966627116852514,227.96673296631258,4.502437890276194,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS635M-66H,Mate Solar Co Ltd,Mono-c-Si,0,635.0,591.0,3.11,,,66.0,18.28,44.7,17.26,36.8,0.011882000000000002,-0.127842,45.6,1.6945342589663523,18.29333596131123,6.325974672947185e-11,0.1575519078247178,215.96110464121534,4.658908958477778,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS640M-66H,Mate Solar Co Ltd,Mono-c-Si,0,640.0,595.8,3.11,,,66.0,18.33,44.9,17.3,37.0,0.0119145,-0.128414,45.6,1.7033209578877384,18.343879954420313,6.458952894206534e-11,0.155446889237618,205.28464653512484,4.814308257241788,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS645M-66H,Mate Solar Co Ltd,Mono-c-Si,0,645.0,600.6,3.11,,,66.0,18.38,45.1,17.34,37.2,0.011947,-0.128986,45.6,1.712110189263013,18.39440055163882,6.593695520776867e-11,0.15335114986796103,195.72820953715689,4.968647808989018,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS650M-66H,Mate Solar Co Ltd,Mono-c-Si,0,650.0,605.3,3.11,,,66.0,18.43,45.3,17.39,37.4,0.0119795,-0.12955799999999998,45.6,1.7204139039683883,18.44409137916251,6.684670370707958e-11,0.15128962427661727,197.8704682874487,5.061893797135497,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS655M-66H,Mate Solar Co Ltd,Mono-c-Si,0,655.0,610.1,3.11,,,66.0,18.48,45.5,17.43,37.6,0.012012000000000002,-0.13013,45.6,1.729205710450962,18.494579952369886,6.822059904456897e-11,0.14921400430779486,189.12783666679368,5.214109904670754,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS660M-66H,Mate Solar Co Ltd,Mono-c-Si,0,660.0,614.9,3.11,,,66.0,18.53,45.7,17.47,37.8,0.012044500000000001,-0.13070199999999998,45.6,1.738000011010217,18.545046185234156,6.961226936409207e-11,0.14714745359685427,181.21818392285414,5.365305569940271,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS665M-66H,Mate Solar Co Ltd,Mono-c-Si,0,665.0,619.7,3.11,,,66.0,18.58,45.9,17.5,38.0,0.012077,-0.131274,45.6,1.7472921671968458,18.596256847423497,7.15046859631463e-11,0.14505970012368416,165.78917189019708,5.575642518640187,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS670M-66H,Mate Solar Co Ltd,Mono-c-Si,0,670.0,624.5,3.11,,,66.0,18.63,46.1,17.54,38.2,0.0121095,-0.131846,45.6,1.7560938537565411,18.646666283757206,7.294151111353745e-11,0.14300939847473174,159.85958081312037,5.724859598163333,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS675M-66H,Mate Solar Co Ltd,Mono-c-Si,0,675.0,629.3,3.11,,,66.0,18.68,46.3,17.58,38.4,0.012142,-0.13241799999999998,45.6,1.7648979849502693,18.69705458861051,7.439644094646879e-11,0.14096799612731092,154.40315022316267,5.87308978831245,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS680M-66H,Mate Solar Co Ltd,Mono-c-Si,0,680.0,634.1,3.11,,,66.0,18.73,46.5,17.62,38.6,0.012174500000000001,-0.13299,45.6,1.7737045529289353,18.7474221087555,7.586955514772819e-11,0.13893543374829695,149.36542691893422,6.020339914772533,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS685M-66H,Mate Solar Co Ltd,Mono-c-Si,0,685.0,638.9,3.11,,,66.0,18.78,46.7,17.66,38.8,0.012207000000000003,-0.133562,45.6,1.7825135475382632,18.79776918278137,7.736093005327037e-11,0.13691165118453563,144.70000545710275,6.166618174301089,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mate Solar Co Ltd MS690M-66H,Mate Solar Co Ltd,Mono-c-Si,0,690.0,643.7,3.11,,,66.0,18.83,46.9,17.7,39.0,0.0122395,-0.13413399999999998,45.6,1.7913249378136495,18.848096142832883,7.887062285593621e-11,0.13489659033024248,140.36708563909167,6.311946715228403,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mateis Solar Corporation iPWR-M10-54BX2S-415W,Mateis Solar Corporation,Mono-c-Si,1,415.0,393.6,1.9,,,18.0,13.5,38.28,12.79,32.48,0.00459,-0.0830676,45.94,1.2641471540328404,13.510639898444344,9.382412733406005e-13,0.13277043175642178,168.46033246333855,0.6751195146367358,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Mateis Solar Corporation iPWR-M10-54BX2S-420W,Mateis Solar Corporation,Mono-c-Si,1,420.0,398.4,1.9,,,18.0,13.57,38.42,12.89,32.61,0.004613800000000001,-0.08337140000000001,45.94,1.2675343267654817,13.578663050500857,9.184190770665259e-13,0.13173942987300685,206.35965465025964,0.43768542478712114,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Mateis Solar Corporation iPWR-M10-54BX2S-425W,Mateis Solar Corporation,Mono-c-Si,1,425.0,403.3,1.9,,,18.0,13.64,38.56,12.99,32.74,0.004637600000000001,-0.0836752,45.94,1.270937949627881,13.64671271087065,8.994493270567181e-13,0.13071864837786684,265.61584422331106,0.20510208602060598,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Mateis Solar Corporation iPWR-M10-54BX2S-430W,Mateis Solar Corporation,Mono-c-Si,1,430.0,408.1,1.9,,,18.0,13.71,38.7,13.1,32.86,0.0046614000000000004,-0.083979,45.94,1.2737755674200248,13.71422290379816,8.69931434768589e-13,0.13060867422163258,424.0316643174166,-0.13591218825585039,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Mateis Solar Corporation iPWR-M10-54BX2S-435W,Mateis Solar Corporation,Mono-c-Si,1,435.0,413.0,1.9,,,18.0,13.78,38.84,13.19,32.99,0.0046852000000000005,-0.0842828,45.94,1.2776238959576136,13.782893739758784,8.604399796807064e-13,0.1295599185154312,616.9648378498248,-0.2797398652883022,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Mateis Solar Corporation iPWR-M10-54BX2S-440W,Mateis Solar Corporation,Mono-c-Si,1,440.0,417.8,1.9,,,18.0,13.85,38.98,13.29,33.11,0.0047090000000000005,-0.0845866,45.94,1.2796340269399233,13.850003871938124,8.166587304411381e-13,0.1296140292524078,463632.27102181496,-0.7794780370279519,-0.264,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X21-335-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,335.0,313.5,1.63,,,96.0,6.23,67.9,5.85,57.3,0.0021618100000000006,-0.1917496,45.3,2.470910628469247,6.236275801744536,7.088899873461465e-12,0.4797604494656435,476.25908680521326,-2.7075926842245464,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X21-350-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,350.0,327.9,1.63,,,96.0,6.5,68.2,5.99,58.4,0.0022555,-0.1925968,45.3,2.524832742953486,6.5082732265682495,1.1537764556004737e-11,0.29183878149014497,229.28806155608513,0.9464084601767886,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-380-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,380.0,353.3,1.77,,,104.0,6.54,75.2,6.02,63.1,0.0024852,-0.171456,47.0,2.7684630380673925,6.554732520055468,9.984068303064845e-12,0.5613633300743547,249.19811212475517,23.607818817082574,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-390-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,390.0,362.8,1.77,,,104.0,6.55,75.3,6.05,64.5,0.002489,-0.171684,47.0,2.7959516493847056,6.5576618062147825,1.262954338717636e-11,0.3132865430448119,267.8254703893034,25.96141033906006,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-395-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,395.0,374.6,1.9,,,112.0,6.29,81.22,5.71,69.12,0.0035223999999999997,-0.1892426,45.0,2.8531545777938794,6.30597100192259,2.555711278369559e-12,0.5013829226395027,197.46404137349623,8.389707002814086,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-395-BLK-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,395.0,372.9,1.9,,,112.0,12.58,40.61,11.46,34.46,0.005660999999999999,-0.09502740000000001,46.01,1.4182236294368424,12.612701373646942,4.340890259778537e-12,0.1365902112852406,52.54534188855115,6.62811421788084,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-395-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,395.0,372.9,1.9,,,112.0,13.04,40.52,11.73,33.67,0.005867999999999999,-0.09481680000000002,46.01,1.4092680472353742,13.103565855662884,3.9462803242960126e-12,0.1993730910601972,40.89971072001414,5.525561027376327,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-395-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,395.0,372.9,1.9,,,112.0,13.04,40.52,11.73,33.67,0.005867999999999999,-0.09481680000000002,46.01,1.4092680472353742,13.103565855662884,3.9462803242960126e-12,0.1993730910601972,40.89971072001414,5.525561027376327,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-400,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,379.4,1.9,,,112.0,6.53,81.09,5.88,67.98,0.0036568,-0.18893970000000002,45.0,2.8389440141607594,6.556608990413552,2.388717661874165e-12,0.6774838042634004,166.25843996525467,7.482000777446653,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-400-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,379.4,1.9,,,112.0,6.3,81.26,5.75,69.55,0.003528,-0.18933580000000003,45.0,2.8548804174492313,6.312318277219606,2.583164366566451e-12,0.425552627516724,217.64257342445,8.45004849016789,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-400-BLK-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,377.7,1.9,,,112.0,12.6,40.63,11.54,34.67,0.00567,-0.09507420000000001,46.01,1.419027035912012,12.62552932770951,4.3826398714823465e-12,0.11809216725210403,58.28439059397363,6.676607006381648,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-400-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,372.4,1.77,,,104.0,6.57,75.4,6.07,66.0,0.0024966000000000003,-0.17191200000000004,47.0,2.8296283671251463,6.571157465062061,1.6823406807575723e-11,0.04661799428312914,264.6129312995543,28.89502959115861,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-400-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,377.7,1.9,,,112.0,13.06,40.55,11.81,33.88,0.005876999999999999,-0.094887,46.01,1.410479520988377,13.113333811582605,3.988773579519931e-12,0.18158814358304143,44.46599794003494,5.585681527155997,-0.28,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-400-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,377.7,1.9,,,112.0,13.06,40.55,11.81,33.88,0.005876999999999999,-0.094887,46.01,1.410479520988377,13.113333811582605,3.988773579519931e-12,0.18158814358304143,44.46599794003494,5.585681527155997,-0.28,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-400,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,376.9,1.87,,,66.0,10.86,48.1,10.12,39.53,0.0045612000000000005,-0.11255400000000002,47.16,1.622648842451533,10.88785689430789,1.4074163704464442e-12,0.33875362919955254,132.06297780592973,-1.746099101680339,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-400-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,400.0,376.1,1.87,,,66.0,11.25,48.1,10.24,39.1,0.0049499999999999995,-0.113516,46.9,1.6644110686249793,11.30895254633697,2.989331966495913e-12,0.36812870052911856,70.2505342213289,3.4575861225372067,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-405-BLK-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,405.0,382.5,1.9,,,112.0,12.62,40.65,11.61,34.89,0.005679,-0.095121,46.01,1.420625104651566,12.639464075759237,4.4912975319615955e-12,0.09874420135704602,64.02316950223872,6.860162333531996,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-405,Maxeon Solar Technologies Ltd,Mono-c-Si,0,405.0,381.8,1.87,,,66.0,10.88,48.1,10.24,39.54,0.004569600000000001,-0.11255400000000002,47.16,1.6157515355834147,10.897638982262963,1.2569082037827576e-12,0.33666957653889446,207.66305790094822,-2.727837830746571,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-405-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,405.0,380.9,1.87,,,66.0,11.26,48.1,10.3,39.3,0.0049544,-0.113516,46.9,1.6647272769062638,11.31006012715501,3.024606374194329e-12,0.34531039444642236,77.67049871239125,3.5318326853649906,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-410-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,389.1,1.9,,,112.0,6.31,81.4,5.82,70.4,0.0035336000000000005,-0.18966200000000003,45.0,2.8593914199436274,6.316723965486592,2.606700760650011e-12,0.28981979483788617,271.9768373409439,8.474455270534197,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-410-BLK-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,387.4,1.9,,,112.0,12.63,40.68,11.68,35.1,0.005683500000000001,-0.0951912,46.01,1.4216410358803013,12.644238042508924,4.517632565847764e-12,0.08168610220229156,72.46048557785568,6.882699537441167,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-410-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,389.1,1.9,,,112.0,6.54,81.18,5.96,68.79,0.0036624,-0.18914940000000002,45.0,2.840292984324733,6.557340106068155,2.380777200738312e-12,0.5407597137463639,203.95310819910068,7.393154676316464,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-410-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,387.4,1.9,,,112.0,13.09,40.59,11.96,34.29,0.005890499999999999,-0.09498060000000001,46.01,1.4123771385538344,13.125728986209811,4.085018391620778e-12,0.14615475103892997,53.54659884881797,5.733427330408438,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-410-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,387.4,1.9,,,112.0,13.09,40.59,11.96,34.29,0.005890499999999999,-0.09498060000000001,46.01,1.4123771385538344,13.125728986209811,4.085018391620778e-12,0.14615475103892997,53.54659884881797,5.733427330408438,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-410,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,386.6,1.87,,,66.0,10.89,48.15,10.24,40.03,0.004573800000000001,-0.11267100000000001,47.16,1.6265973341270625,10.906429296584905,1.4847039377886319e-12,0.2869285122588068,190.18778339025565,-1.3650208425790333,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-410-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,410.0,385.7,1.87,,,66.0,11.28,48.1,10.37,39.6,0.004963199999999999,-0.113516,46.9,1.6670333253166285,11.320562192063248,3.169864480069209e-12,0.3114529107122991,86.61240069304407,3.9004722989903544,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-415,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,393.9,1.9,,,112.0,6.55,81.23,6.0,69.2,0.0036680000000000003,-0.18926590000000001,45.0,2.8422295270444633,6.563733306903824,2.4024236123894638e-12,0.4729480329908077,225.56909554658998,7.439774154832509,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-415-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,393.9,1.9,,,112.0,6.32,81.4,5.86,70.8,0.0035392000000000006,-0.18966200000000003,45.0,2.859773604508928,6.3244067941447835,2.6358626961720836e-12,0.21600713420159737,309.78644424819225,8.537995098956404,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-415-BLK-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,392.2,1.9,,,112.0,12.64,40.7,11.75,35.31,0.005688,-0.09523800000000002,46.01,1.4224679205709647,12.649715732772222,4.55852318012892e-12,0.06399369530265368,83.25468885381154,6.932953118936996,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-415-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,393.9,1.9,,,112.0,6.55,81.23,6.0,69.2,0.0036680000000000003,-0.18926590000000001,45.0,2.8422295270444633,6.563733306903824,2.4024236123894638e-12,0.4729480329908077,225.56909554658998,7.439774154832509,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-415-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,392.2,1.9,,,112.0,13.1,40.61,12.03,34.49,0.005895,-0.09502740000000001,46.01,1.413236735437878,13.128480662594928,4.124492571814644e-12,0.12931252744698615,59.47874648936356,5.790293701442603,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-415-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,392.2,1.9,,,112.0,13.1,40.61,12.03,34.49,0.005895,-0.09502740000000001,46.01,1.413236735437878,13.128480662594928,4.124492571814644e-12,0.12931252744698615,59.47874648936356,5.790293701442603,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-415,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,391.4,1.87,,,66.0,11.52,48.07,10.55,39.33,0.0048384000000000005,-0.11248380000000001,47.16,1.6309996189865827,11.570997567580672,1.7348632638836777e-12,0.3384446407633586,76.45231817657904,-0.43565676044962853,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-415-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,415.0,390.5,1.87,,,66.0,11.29,48.1,10.43,39.8,0.0049676,-0.113516,46.9,1.6673134266017495,11.32338478292134,3.2049507821783344e-12,0.2893021644328364,97.83561069538233,3.968274618185985,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-420,Maxeon Solar Technologies Ltd,Mono-c-Si,0,420.0,398.8,1.9,,,112.0,6.56,81.27,6.03,69.61,0.0036735999999999995,-0.1893591,45.0,2.8462775142720864,6.570916289448887,2.479919397789212e-12,0.40342081322337975,242.43041081486467,7.695078944106511,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-420-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,420.0,398.8,1.9,,,112.0,6.32,81.5,5.89,71.3,0.0035392000000000006,-0.18989500000000004,45.0,2.8640576587219058,6.3224867945736865,2.6708738934830496e-12,0.14114644243351016,358.71298979371034,8.634740329347677,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-420-BLK-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,420.0,397.0,1.9,,,112.0,12.65,40.73,11.82,35.52,0.0056925,-0.09530820000000001,46.01,1.4234706733744384,12.656136081194463,4.583631745444188e-12,0.047372615171061214,97.66226410573614,6.951927402416734,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-420-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,420.0,398.8,1.9,,,112.0,6.56,81.27,6.03,69.61,0.0036735999999999995,-0.1893591,45.0,2.8462775142720864,6.570916289448887,2.479919397789212e-12,0.40342081322337975,242.43041081486467,7.695078944106511,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-420,Maxeon Solar Technologies Ltd,Mono-c-Si,0,420.0,396.3,1.87,,,66.0,11.53,48.1,10.62,39.56,0.0048426,-0.11255400000000002,47.16,1.6317975536377547,11.571762127567725,1.7403573565420533e-12,0.3160887452682401,87.26814093287496,-0.43882238841805743,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-420-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,420.0,395.4,1.87,,,66.0,11.3,48.2,10.49,40.0,0.004972,-0.113752,46.9,1.6693815259257332,11.327758777840195,3.1482513906914866e-12,0.2770259896737258,112.77130796036009,3.7874486040527198,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-425,Maxeon Solar Technologies Ltd,Mono-c-Si,0,425.0,403.6,1.9,,,112.0,6.57,81.32,6.07,70.01,0.0036792000000000005,-0.1894756,45.0,2.8479779534035217,6.578171932251414,2.4962966479598885e-12,0.3392911241266836,272.7803679397667,7.719415685318569,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-425-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,425.0,403.6,1.9,,,112.0,6.57,81.32,6.07,70.01,0.0036792000000000005,-0.1894756,45.0,2.8479779534035217,6.578171932251414,2.4962966479598885e-12,0.3392911241266836,272.7803679397667,7.719415685318569,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-425-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,425.0,401.9,1.9,,,112.0,13.13,40.66,12.18,34.9,0.0059085,-0.09514439999999999,46.01,1.4152643334711328,13.14658265369266,4.204118371410323e-12,0.09608285898816596,76.07756649212757,5.895478275597722,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-425-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,425.0,401.9,1.9,,,112.0,13.13,40.66,12.18,34.9,0.0059085,-0.09514439999999999,46.01,1.4152643334711328,13.14658265369266,4.204118371410323e-12,0.09608285898816596,76.07756649212757,5.895478275597722,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-425,Maxeon Solar Technologies Ltd,Mono-c-Si,0,425.0,401.1,1.87,,,66.0,11.55,48.13,10.68,39.8,0.004851,-0.11262420000000002,47.16,1.6341347469026903,11.585145336844553,1.7926591122913017e-12,0.2927051049923867,96.19324411193631,-0.22212705950435035,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-425-BLK,Maxeon Solar Technologies Ltd,Mono-c-Si,0,425.0,400.2,1.87,,,66.0,11.32,48.2,10.58,40.3,0.0049808000000000005,-0.113752,46.9,1.6701359917358556,11.339539292914267,3.218517176774687e-12,0.24447319746135537,141.63442788966884,3.9343107888128146,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-430,Maxeon Solar Technologies Ltd,Mono-c-Si,0,430.0,408.5,1.9,,,112.0,6.57,81.36,6.11,70.42,0.0036792000000000005,-0.1895688,45.0,2.84759201639479,6.575523807840351,2.469879744709059e-12,0.27406269785029075,325.96932724864484,7.597278551131398,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-430-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,430.0,408.5,1.9,,,112.0,6.57,81.36,6.11,70.42,0.0036792000000000005,-0.1895688,45.0,2.84759201639479,6.575523807840351,2.469879744709059e-12,0.27406269785029075,325.96932724864484,7.597278551131398,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-430-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,430.0,406.7,1.9,,,112.0,13.15,40.68,12.25,35.11,0.0059175,-0.0951912,46.01,1.4168092835219797,13.162066398969642,4.302883339755102e-12,0.07876325853450783,85.83644985977571,6.067634722954222,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-430-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,430.0,406.7,1.9,,,112.0,13.15,40.68,12.25,35.11,0.0059175,-0.0951912,46.01,1.4168092835219797,13.162066398969642,4.302883339755102e-12,0.07876325853450783,85.83644985977571,6.067634722954222,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-430,Maxeon Solar Technologies Ltd,Mono-c-Si,0,430.0,405.9,1.87,,,66.0,11.56,48.15,10.74,40.03,0.0048552000000000005,-0.11267100000000001,47.16,1.6354297513415104,11.588367364060522,1.8234392407303076e-12,0.2699939375052386,110.0253767693613,-0.106442024087259,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-435,Maxeon Solar Technologies Ltd,Mono-c-Si,0,435.0,413.3,1.9,,,112.0,6.58,81.4,6.14,70.8,0.0036848,-0.18966200000000003,45.0,2.8509640464561516,6.583876178399815,2.532034298283166e-12,0.21249217203662343,360.715722642127,7.790921076200663,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-435-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,435.0,413.3,1.9,,,112.0,6.58,81.4,6.14,70.8,0.0036848,-0.18966200000000003,45.0,2.8509640464561516,6.583876178399815,2.532034298283166e-12,0.21249217203662343,360.715722642127,7.790921076200663,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-435-COM-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,435.0,411.6,1.9,,,112.0,13.16,40.7,12.32,35.31,0.005921999999999999,-0.09523800000000002,46.01,1.417632187527787,13.168159342386998,4.340408451127335e-12,0.06276070165212323,101.22517168916683,6.115625460433995,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX3-435-R,Maxeon Solar Technologies Ltd,Mono-c-Si,0,435.0,411.6,1.9,,,112.0,13.16,40.7,12.32,35.31,0.005921999999999999,-0.09523800000000002,46.01,1.417632187527787,13.168159342386998,4.340408451127335e-12,0.06276070165212323,101.22517168916683,6.115625460433995,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-435,Maxeon Solar Technologies Ltd,Mono-c-Si,0,435.0,410.8,1.87,,,66.0,11.57,48.18,10.82,40.26,0.004859400000000001,-0.11274120000000001,47.16,1.6355131174610047,11.590874831241072,1.8075286649073388e-12,0.24858380879023032,137.77905958140124,-0.21346909352344168,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-440,Maxeon Solar Technologies Ltd,Mono-c-Si,0,440.0,415.6,1.87,,,66.0,11.58,48.21,10.87,40.49,0.0048636,-0.11281140000000002,47.16,1.622423074721574,11.580006252604523,1.4412017209150218e-12,0.2301055400560019,426162.36221320124,-2.1976588532574453,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-445,Maxeon Solar Technologies Ltd,Mono-c-Si,0,445.0,420.4,1.87,,,66.0,11.6,48.2,10.93,40.7,0.004872,-0.11278800000000001,47.2,1.6386184326253561,11.612454576742277,1.9079711509658653e-12,0.20448222864493565,190.45157972665726,0.1846250343780371,-0.276,N,2025.7.3,6/23/2025,4.0,bootstrapping +Maxeon Solar Technologies Ltd SPR-MAX6-450-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,450.0,422.9,2.12,,,72.0,11.51,52.43,10.52,42.76,0.0042587,-0.12373479999999999,46.51,1.8124564951013062,11.56331092698593,2.9860384889276528e-12,0.3769821623073301,81.39165713111308,3.3439677639063308,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-455-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,455.0,427.7,2.12,,,72.0,11.52,52.45,10.58,42.99,0.0042623999999999995,-0.12378200000000002,46.51,1.813480082822615,11.564982612256959,3.0201789281239905e-12,0.3534951939575564,90.52974988295603,3.4147942038856822,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-460-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,460.0,432.6,2.12,,,72.0,11.54,52.48,10.64,43.23,0.004269799999999999,-0.12385279999999997,46.51,1.8156078635436965,11.578296096286271,3.0912099584466862e-12,0.32987318174208197,99.40273000795703,3.58335178560166,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-465-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,465.0,437.4,2.12,,,72.0,11.55,52.51,10.7,43.46,0.0042735,-0.1239236,46.51,1.8167852488341514,11.581454437380977,3.1167699141859995e-12,0.3079008303463315,113.0605055404812,3.627060362497221,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-470-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,470.0,442.2,2.12,,,72.0,11.56,52.53,10.76,43.69,0.0042772,-0.12397079999999999,46.51,1.8177748053930773,11.585219498981413,3.1502735168256126e-12,0.2852566478143015,130.7546533843457,3.6916695012055714,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X21-470-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,470.0,438.0,2.16,,,128.0,6.45,91.5,6.06,77.6,0.00199305,-0.26836950000000004,45.67,3.4135510121971593,6.455116375900208,1.4429271066964493e-11,0.5236993183591022,660.2057169760643,-1.026485343244535,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X22-470-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,470.0,438.0,2.16,,,128.0,6.89,91.5,6.03,77.9,0.00212901,-0.26836950000000004,45.7,3.559736517681976,6.910074349009089,4.256608397612477e-11,0.37425306288495847,128.45266404028436,7.708920636863754,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-475-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,475.0,447.0,2.12,,,72.0,11.57,52.56,10.82,43.92,0.0042809,-0.12404160000000002,46.51,1.783448661788486,11.570007203795223,1.8375543525959756e-12,0.2707715184163072,434886.08450431906,-0.9672110097124201,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X22-475-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,475.0,442.8,2.16,,,128.0,6.45,92.5,6.07,78.5,0.00199305,-0.2713025,45.7,3.449142524770276,6.454581248925482,1.4265002347421032e-11,0.5206880965876528,733.0835531616148,-1.124559381692977,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-MAX6-480-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,480.0,451.9,2.12,,,72.0,11.58,52.59,10.87,44.15,0.0042845999999999995,-0.1241124,46.51,1.790231971211237,11.580006598557892,2.0222472799985517e-12,0.2485405139698433,436171.4664973712,-0.18383965901735588,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X22-480-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,480.0,452.9,2.16,,,128.0,6.48,92.9,6.08,79.0,0.0026568000000000004,-0.219244,46.23,3.2160463578545153,6.487064109611286,1.7992606781123011e-12,0.5848593932093937,536.4991596543495,3.766545179262637,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-X22-485-COM,Maxeon Solar Technologies Ltd,Mono-c-Si,0,485.0,457.7,2.16,,,128.0,6.55,92.7,6.16,78.8,0.0026855000000000004,-0.218772,46.23,3.2050782766638855,6.556469202310742,1.758427561446191e-12,0.5839804013756629,591.274065006741,3.4673558088613956,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-495-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,495.0,444.6,2.6,,,115.0,14.55,46.0,13.42,36.9,0.006693000000000001,-0.13754,46.02,1.9823980404356036,14.585259255966188,1.1827754476854642e-09,0.24885382749779214,102.6914415400656,29.45031995985146,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-500-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,500.0,449.3,2.6,,,115.0,14.62,46.1,13.48,37.1,0.0067252,-0.137839,46.02,1.9908125755734598,14.654731335049222,1.2457031312019561e-09,0.2376160081327028,100.02341179270103,29.947459990600183,-0.493,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-505-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,505.0,453.9,2.6,,,115.0,14.68,46.1,13.55,37.3,0.006752800000000001,-0.137839,46.02,1.9958650165371081,14.711410215483848,1.3271913780662784e-09,0.2191701698352164,102.43223699495452,30.57094004366352,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-510-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,510.0,457.8,2.6,,,115.0,14.74,46.1,13.64,37.4,0.0067804,-0.137839,46.35,1.9961955411489882,14.76739857441837,1.3413905470412612e-09,0.20977578571111935,112.8560764016401,30.630635597241575,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-515-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,515.0,462.5,2.6,,,115.0,14.75,46.3,13.66,37.7,0.006784999999999999,-0.13843699999999998,46.35,2.0082422821442787,14.775266847614049,1.3963196838251137e-09,0.1986527058876316,115.96729400904492,31.047283130635748,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-520-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,520.0,467.1,2.6,,,115.0,14.76,46.6,13.69,38.0,0.006789600000000001,-0.139334,46.35,2.021292746871711,14.783088126349313,1.400183252630013e-09,0.19513353760788,124.74687304829621,31.063406994715482,-0.493,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-525-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,525.0,472.6,2.6,,,115.0,14.77,46.8,13.71,38.3,0.006794199999999999,-0.13993199999999997,46.02,2.0332933592621933,14.791167190173915,1.455734208128617e-09,0.18409375692367638,128.456601593884,31.468372262414842,-0.493,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-530-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,530.0,476.5,2.6,,,115.0,14.78,47.1,13.73,38.6,0.006798799999999999,-0.140829,46.35,2.0471167058887336,14.79995067096707,1.4708469256309787e-09,0.1805445341722215,133.75233066103212,31.56841933327646,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-535-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,535.0,481.2,2.6,,,115.0,14.79,47.4,13.76,38.9,0.0068034,-0.141726,46.35,2.060106280863409,14.808048298221383,1.473458793509453e-09,0.17710461475999342,145.13156690199781,31.57395467470422,-0.493,N,2025.7.3,6/23/2025,4.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-540-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,540.0,485.9,2.6,,,115.0,14.8,47.6,13.78,39.2,0.006808000000000001,-0.142324,46.35,2.072045453772413,14.816398153714461,1.5294037234050558e-09,0.16617445752963642,149.9792315991035,31.962922412553883,-0.493,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-545-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,545.0,490.5,2.6,,,115.0,14.83,47.8,13.81,39.5,0.0068218,-0.142922,46.35,2.0846810960751325,14.845385088994556,1.5999926862909781e-09,0.1549796702945847,149.38808557661653,32.4258420771244,-0.493,N,2025.7.3,6/23/2025,2.0,first_pass +Maxeon Solar Technologies Ltd SPR-P5-550-UPP,Maxeon Solar Technologies Ltd,Mono-c-Si,0,550.0,495.2,2.6,,,115.0,14.86,48.0,13.84,39.8,0.006835600000000001,-0.14351999999999998,46.35,2.0973079602025333,14.87435857387665,1.6728134229763585e-09,0.1438403198760878,148.86350223208726,32.883925374780794,-0.493,N,2025.7.3,6/23/2025,2.0,first_pass +MECEN SOLAR VINA COLTD MC7G54M(H)-395,MECEN SOLAR VINA COLTD,Mono-c-Si,1,395.0,366.3,1.952,,,54.0,13.69,36.8,12.81,30.9,0.006160499999999999,-0.111872,43.8,1.4725492198353192,13.702204296194306,1.8784396833558907e-10,0.10861221918611189,121.83425395380112,10.290900322558151,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +MECEN SOLAR VINA COLTD MC7G54M(H)-400,MECEN SOLAR VINA COLTD,Mono-c-Si,1,400.0,371.1,1.952,,,54.0,13.78,37.0,12.89,31.1,0.006201,-0.11248,43.8,1.4816506403952396,13.792208296816604,1.9252049024771315e-10,0.10555424549089813,119.14336308538994,10.452941401339066,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +MECEN SOLAR VINA COLTD MC7G54M(H)-405,MECEN SOLAR VINA COLTD,Mono-c-Si,1,405.0,375.9,1.952,,,54.0,13.86,37.3,12.97,31.2,0.0062369999999999995,-0.11339199999999999,43.8,1.4893608212952796,13.873342463972516,1.8033050157607767e-10,0.11949034549573365,124.12521695710795,9.818082033691994,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +MECEN SOLAR VINA COLTD MC7G54M(H)-410,MECEN SOLAR VINA COLTD,Mono-c-Si,1,410.0,380.6,1.952,,,54.0,13.94,37.5,13.05,31.4,0.006273,-0.11399999999999999,43.8,1.49789018681481,13.952857775483245,1.8309366057063383e-10,0.11657404976504676,126.38596008827554,9.900462086217754,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +MECEN SOLAR VINA COLTD MC7G54M(H)-415,MECEN SOLAR VINA COLTD,Mono-c-Si,1,415.0,385.4,1.952,,,54.0,14.02,37.8,13.13,31.6,0.0063089999999999995,-0.114912,43.8,1.5082213166258647,14.033059574413771,1.7927496411071023e-10,0.12141826479301389,130.3475953683909,9.66137331334975,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +MECEN SOLAR VINA COLTD MC7G72M-530,MECEN SOLAR VINA COLTD,Mono-c-Si,1,530.0,489.2,2.59,,,72.0,13.72,49.32,12.83,41.32,0.00801248,-0.1447542,45.4,1.976098554178514,13.733145878556856,1.9437463509665312e-10,0.15280405839453212,159.47749169418748,14.394409178935291,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +MECEN SOLAR VINA COLTD MC7G72M-535,MECEN SOLAR VINA COLTD,Mono-c-Si,1,535.0,493.9,2.59,,,72.0,13.79,49.46,12.9,41.48,0.008053359999999999,-0.1451651,45.4,1.9824507304374503,13.802685946358062,1.9726422351956198e-10,0.14866979784993564,161.60848482770635,14.482677686173627,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +MECEN SOLAR VINA COLTD MC7G72M-540,MECEN SOLAR VINA COLTD,Mono-c-Si,1,540.0,498.7,2.59,,,72.0,13.86,49.6,12.97,41.64,0.00809424,-0.145576,45.4,1.9888029938778018,13.87223531479409,2.001791940217873e-10,0.1445806129008945,163.77897794734116,14.570448961699775,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +MECEN SOLAR VINA COLTD MC7G72M-545,MECEN SOLAR VINA COLTD,Mono-c-Si,1,545.0,503.4,2.59,,,72.0,13.93,49.76,13.04,41.8,0.008135120000000001,-0.1460456,45.4,1.9955217285242652,13.941902369896981,2.020245533138922e-10,0.14208992431978462,166.29568067230187,14.60754433055536,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +MECEN SOLAR VINA COLTD MC7G72M-550,MECEN SOLAR VINA COLTD,Mono-c-Si,1,550.0,508.2,2.59,,,72.0,14.0,49.92,13.11,41.96,0.008176000000000001,-0.1465152,45.4,2.0022412764382227,14.01157557271183,2.0387789236238984e-10,0.1396257885275673,168.86949330184873,14.644485208268554,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc Solstice Shingle 68W-01,Merlin Solar Technologies Inc,Mono-c-Si,0,68.0,60.8,0.53,,,14.0,9.3,9.37,8.83,7.7,0.0034410000000000005,-0.024643099999999998,53.61,0.3391371346305482,9.30419486878522,9.263471319283599e-12,0.07047660825732945,156.24624097781137,3.2876055394832684,-0.342,Y,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc Solstice Shingle 70W-01,Merlin Solar Technologies Inc,Mono-c-Si,0,70.0,62.6,0.53,,,14.0,9.44,9.51,8.96,7.82,0.0034928,-0.025011300000000004,53.61,0.3443642860692408,9.44452805013361,9.52016433282402e-12,0.06983351264693886,145.5876918197486,3.3933867643187954,-0.342,Y,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc Solstice Shingle 72W-01,Merlin Solar Technologies Inc,Mono-c-Si,0,72.0,64.4,0.53,,,14.0,9.57,9.65,9.08,7.93,0.0035409,-0.025379500000000003,53.61,0.349382266710063,9.574902484083458,9.60846118546287e-12,0.07054542663957743,137.70972617728043,3.3574215296737306,-0.342,Y,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc FXS 95-B,Merlin Solar Technologies Inc,Mono-c-Si,0,95.0,83.8,0.75,,,24.0,8.46,15.08,8.1,11.84,0.0043146,-0.046748000000000005,51.28,0.5922122121378535,8.460176617117547,7.387140303383453e-11,0.16890173035401673,8090.46541484189,4.133794210774854,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 100-B,Merlin Solar Technologies Inc,Mono-c-Si,0,100.0,88.3,0.75,,,24.0,8.55,15.33,8.18,12.3,0.0043605,-0.047522999999999996,51.28,0.607651238000847,8.55000134876213,9.450598936978813e-11,0.13714445069759118,869415.7083198042,6.130556721265468,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 100-W,Merlin Solar Technologies Inc,Mono-c-Si,0,100.0,91.5,0.75,,,24.0,8.65,15.21,8.31,12.06,0.0027680000000000005,-0.046694700000000006,44.65,0.5802628619628998,8.650001772306991,3.574176958144115e-11,0.15307209466937458,747206.3399770572,-0.7593020058662572,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX105,Merlin Solar Technologies Inc,Mono-c-Si,0,105.0,96.0,0.757,,,24.0,8.85,15.4,8.6,12.5,0.0039825,-0.04774,45.28,0.60252076587576,8.850091333250514,7.024275886790647e-11,0.08692082462155237,8422.461757532203,3.4105013827656623,-0.395,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 105-W,Merlin Solar Technologies Inc,Mono-c-Si,0,105.0,96.2,0.75,,,24.0,8.81,15.5,8.5,12.36,0.0028192000000000004,-0.047585,44.65,0.5939892955447839,8.810121248394006,4.0935469906752936e-11,0.13524323282172696,9826.865272393738,0.18266082759494298,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX110,Merlin Solar Technologies Inc,Mono-c-Si,0,110.0,100.7,0.757,,,24.0,8.98,15.6,8.65,12.7,0.004041,-0.04836,45.28,0.6087080900141282,8.980110288334327,6.653827115451783e-11,0.10246779502387354,8343.246330464435,2.8394605280605862,-0.395,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc RFP-F024B114L,Merlin Solar Technologies Inc,Mono-c-Si,0,114.0,101.9,0.76,,,24.0,8.97,16.25,8.49,13.43,0.0038570999999999996,-0.043225000000000006,55.49,0.5872457751051953,8.97650303395753,8.523531606226269e-12,0.11729384548663067,161.78998865736708,1.6606003897642427,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F024B117L,Merlin Solar Technologies Inc,Mono-c-Si,0,117.0,104.7,0.76,,,24.0,9.02,16.3,8.59,13.62,0.0038786,-0.043358,55.49,0.5905669450816535,9.02224229388898,9.258014007011938e-12,0.09727053658312575,391.28690425038945,2.278224396060374,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F024W117L,Merlin Solar Technologies Inc,Mono-c-Si,0,117.0,105.9,0.76,,,24.0,9.15,16.25,8.67,13.49,0.0048495000000000005,-0.042575,53.69,0.58465320961643,9.155859403914224,7.695075534536572e-12,0.10799059821498125,168.63728697754104,2.0598476737216953,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F024B120L,Merlin Solar Technologies Inc,Mono-c-Si,0,120.0,107.5,0.76,,,24.0,9.07,16.35,8.69,13.81,0.0039000999999999997,-0.043491,55.49,0.5946178002630613,9.070000682121469,1.0374361390306383e-11,0.07520379971034127,999999.1990307687,3.16685896816592,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc RFP-F024W120L,Merlin Solar Technologies Inc,Mono-c-Si,0,120.0,108.7,0.76,,,24.0,9.2,16.3,8.77,13.69,0.004876,-0.042706,53.69,0.5881790822051878,9.201898120927222,8.445068109609307e-12,0.08719731349852422,422.6365576070203,2.770876158161679,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F024W123L,Merlin Solar Technologies Inc,Mono-c-Si,0,123.0,111.5,0.76,,,24.0,9.25,16.35,8.87,13.89,0.0049025,-0.042837,53.69,0.5925111303333683,9.250000592935843,9.594832061250917e-12,0.06409930881397391,999998.9832775891,3.7860240793872637,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 145L-B,Merlin Solar Technologies Inc,Mono-c-Si,0,145.0,128.0,1.11,,,36.0,8.35,22.67,8.1,18.02,0.0042585,-0.070277,51.28,0.9006844289721718,8.350159632555057,9.783382989776209e-11,0.18312972842769915,9579.107328710135,6.630975147018978,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 145S-B,Merlin Solar Technologies Inc,Mono-c-Si,0,145.0,128.2,1.05,,,36.0,8.35,22.67,8.1,18.02,0.0042585,-0.070277,51.28,0.9006844289721718,8.350159632555057,9.783382989776209e-11,0.18312972842769915,9579.107328710135,6.630975147018978,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX 150L-B,Merlin Solar Technologies Inc,Mono-c-Si,0,150.0,134.1,1.11,,,36.0,8.35,22.67,8.1,18.58,0.0025885,-0.07095710000000001,49.0,0.8925724931294907,8.350100040537264,7.782950106393439e-11,0.11750833404233803,9807.985087467017,3.9204500758318956,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 150L-B,Merlin Solar Technologies Inc,Mono-c-Si,0,150.0,132.5,1.11,,,36.0,8.46,23.01,8.21,18.35,0.0043146,-0.071331,51.28,0.9157222704597877,8.460153148081666,1.0337874160921544e-10,0.17398192146656485,9610.900577503624,6.992805953414621,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 150L-W,Merlin Solar Technologies Inc,Mono-c-Si,0,150.0,137.3,1.11,,,36.0,8.61,22.67,8.35,18.02,0.0027551999999999997,-0.0695969,44.65,0.869540106702677,8.610172625275187,4.0953495898253566e-11,0.19167957082534418,9560.380348217825,0.37173991017119723,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 150S-B,Merlin Solar Technologies Inc,Mono-c-Si,0,150.0,132.7,1.05,,,36.0,8.46,23.01,8.21,18.35,0.0043146,-0.071331,51.28,0.9157222704597877,8.460153148081666,1.0337874160921544e-10,0.17398192146656485,9610.900577503624,6.992805953414621,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 150S-W,Merlin Solar Technologies Inc,Mono-c-Si,0,150.0,137.5,1.05,,,36.0,8.61,22.67,8.35,18.02,0.0027551999999999997,-0.0695969,44.65,0.869540106702677,8.610172625275187,4.0953495898253566e-11,0.19167957082534418,9560.380348217825,0.37173991017119723,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX 155L-B,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,138.7,1.11,,,36.0,8.46,23.01,8.21,18.92,0.0026226,-0.07202130000000001,49.0,0.9074642026910388,8.460092967142534,8.224747041300839e-11,0.10809707766499368,9836.83741422462,4.27251168067618,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX155L,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,141.7,1.113,,,36.0,8.84,22.94,8.45,18.8,0.0038896,-0.07111400000000001,45.28,0.89461922912727,8.840001410408437,6.45933436777024e-11,0.15952025379087445,999998.9610610405,2.735800299037648,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX155S,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,141.8,1.054,,,36.0,8.84,22.94,8.45,18.8,0.0038896,-0.07111400000000001,45.28,0.89461922912727,8.840001410408437,6.45933436777024e-11,0.15952025379087445,999998.9610610405,2.735800299037648,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 155L-B,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,137.1,1.11,,,36.0,8.55,23.25,8.28,18.75,0.0043605,-0.072075,51.28,0.9291062049207269,8.55013747834728,1.1588941870234967e-10,0.15498021281589305,9638.494703683127,7.8901447668963325,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 155L-W,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,142.0,1.11,,,36.0,8.72,23.01,8.46,18.35,0.0027904000000000006,-0.0706407,44.65,0.8840107521358432,8.720166404838805,4.326262560034831e-11,0.1830326458578957,9591.3481659696,0.7126366542853245,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 155S-B,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,137.3,1.05,,,36.0,8.55,23.25,8.28,18.75,0.0043605,-0.072075,51.28,0.9291062049207269,8.55013747834728,1.1588941870234967e-10,0.15498021281589305,9638.494703683127,7.8901447668963325,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 155S-W,Merlin Solar Technologies Inc,Mono-c-Si,0,155.0,142.2,1.05,,,36.0,8.72,23.01,8.46,18.35,0.0027904000000000006,-0.0706407,44.65,0.8840107521358432,8.720166404838805,4.326262560034831e-11,0.1830326458578957,9591.3481659696,0.7126366542853245,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX 160L-B,Merlin Solar Technologies Inc,Mono-c-Si,0,160.0,143.3,1.11,,,36.0,8.55,23.25,8.28,19.34,0.0026505,-0.0727725,49.0,0.9209340089346021,8.550075276389654,9.2812173707892e-11,0.08713684216139145,9897.142180099154,5.199630417838102,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX160L,Merlin Solar Technologies Inc,Mono-c-Si,0,160.0,146.3,1.113,,,36.0,8.88,23.12,8.55,18.89,0.0039071999999999996,-0.071672,45.28,0.9035548776764721,8.880135618821681,6.849395095527449e-11,0.1461876248679678,9572.035558335678,3.185311363233323,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX160S,Merlin Solar Technologies Inc,Mono-c-Si,0,160.0,146.5,1.054,,,36.0,8.88,23.12,8.55,18.89,0.0039071999999999996,-0.071672,45.28,0.9035548776764721,8.880135618821681,6.849395095527449e-11,0.1461876248679678,9572.035558335678,3.185311363233323,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 160L-W,Merlin Solar Technologies Inc,Mono-c-Si,0,160.0,146.7,1.11,,,36.0,8.81,23.25,8.54,18.75,0.0028192000000000004,-0.0713775,44.65,0.8971790537643209,8.81000171406371,4.902576730763336e-11,0.16077991207673156,826335.8786061198,1.645608209921108,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FXS 160S-W,Merlin Solar Technologies Inc,Mono-c-Si,0,160.0,146.9,1.05,,,36.0,8.81,23.25,8.54,18.75,0.0028192000000000004,-0.0713775,44.65,0.8971790537643209,8.81000171406371,4.902576730763336e-11,0.16077991207673156,826335.8786061198,1.645608209921108,-0.399,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc GX160,Merlin Solar Technologies Inc,Mono-c-Si,0,160.0,141.3,1.011,,,36.0,8.95,22.85,8.6,18.7,0.004117,-0.07586200000000001,51.86,0.9227452561943017,8.950107778932633,1.5749496825574637e-10,0.13427009270379803,11149.87504755993,2.895981431273023,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX165L,Merlin Solar Technologies Inc,Mono-c-Si,0,165.0,151.0,1.113,,,36.0,8.95,23.28,8.65,18.98,0.003938,-0.072168,45.28,0.9104931370166498,8.950129622321382,7.037628630660597e-11,0.13902097975250402,9598.961832350546,3.345430925373604,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc FX165S,Merlin Solar Technologies Inc,Mono-c-Si,0,165.0,151.2,1.054,,,36.0,8.95,23.28,8.65,18.98,0.003938,-0.072168,45.28,0.9104931370166498,8.950129622321382,7.037628630660597e-11,0.13902097975250402,9598.961832350546,3.345430925373604,-0.396,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc GX165,Merlin Solar Technologies Inc,Mono-c-Si,0,165.0,145.8,1.011,,,36.0,9.05,23.1,8.74,18.95,0.004163,-0.07669200000000001,51.86,0.9361351935018412,9.050107415119871,1.7374801215015508e-10,0.11278475557784808,9502.435783758945,3.6200388203473484,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc GX170,Merlin Solar Technologies Inc,Mono-c-Si,0,170.0,150.4,1.011,,,36.0,9.15,23.4,8.9,19.15,0.004209,-0.077688,51.86,0.9504167762503491,9.15007471934873,1.8563447699352881e-10,0.09238333033473548,11312.838671350433,4.08123391322281,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc RFP-F036B170L,Merlin Solar Technologies Inc,Mono-c-Si,0,170.0,152.2,1.09,,,36.0,8.96,24.36,8.49,20.07,0.0038528000000000004,-0.06479760000000001,55.49,0.8785026423268096,8.965790523720836,8.051636018797019e-12,0.18451520159581783,285.5106359479151,1.1933973678555498,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036B170S,Merlin Solar Technologies Inc,Mono-c-Si,0,170.0,152.2,1.09,,,36.0,8.96,24.36,8.49,20.07,0.0038528000000000004,-0.06479760000000001,55.49,0.8785026423268096,8.965790523720836,8.051636018797019e-12,0.18451520159581783,285.5106359479151,1.1933973678555498,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036B175L,Merlin Solar Technologies Inc,Mono-c-Si,0,175.0,156.8,1.09,,,36.0,9.02,24.45,8.59,20.4,0.0038786,-0.065037,55.49,0.8852067193177348,9.022234658605388,9.075308180562419e-12,0.14990248387854005,605.0680050607041,2.111922368156499,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036B175S,Merlin Solar Technologies Inc,Mono-c-Si,0,175.0,156.8,1.09,,,36.0,9.02,24.45,8.59,20.4,0.0038786,-0.065037,55.49,0.8852067193177348,9.022234658605388,9.075308180562419e-12,0.14990248387854005,605.0680050607041,2.111922368156499,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036W175L,Merlin Solar Technologies Inc,Mono-c-Si,0,175.0,158.6,1.09,,,36.0,9.15,24.4,8.67,20.2,0.0048495000000000005,-0.063928,53.7,0.8766789281161478,9.155981018953563,7.409693240754017e-12,0.16951933112505174,259.33739738784965,1.74416455544707,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036W175S,Merlin Solar Technologies Inc,Mono-c-Si,0,175.0,158.6,1.09,,,36.0,9.15,24.38,8.67,20.22,0.0048495000000000005,-0.0638756,53.69,0.8767476943793716,9.1559029336715,7.595907954615889e-12,0.16454934937382765,255.06411547375595,1.9514007220913399,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036B180L,Merlin Solar Technologies Inc,Mono-c-Si,0,180.0,161.4,1.09,,,36.0,9.07,24.52,8.69,20.72,0.0039000999999999997,-0.06522320000000001,55.49,0.8919134531029227,9.070001012760896,1.0428413766051248e-11,0.11165801396895204,999999.4955859989,3.2104585576403797,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc RFP-F036B180S,Merlin Solar Technologies Inc,Mono-c-Si,0,180.0,161.4,1.09,,,36.0,9.07,24.52,8.69,20.72,0.0039000999999999997,-0.06522320000000001,55.49,0.8919134531029227,9.070001012760896,1.0428413766051248e-11,0.11165801396895204,999999.4955859989,3.2104585576403797,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc RFP-F036W180L,Merlin Solar Technologies Inc,Mono-c-Si,0,180.0,163.2,1.09,,,36.0,9.2,24.5,8.77,20.5,0.004876,-0.06419,53.7,0.8824425795912878,9.201874132284459,8.02635655170716e-12,0.14109533631050242,692.6283290969203,2.3437499093720247,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036W180S,Merlin Solar Technologies Inc,Mono-c-Si,0,180.0,163.2,1.09,,,36.0,9.2,24.45,8.77,20.54,0.004876,-0.064059,53.69,0.8823743861544486,9.201898711432166,8.472977425305604e-12,0.13014467613974443,630.6019002275557,2.7986401744938605,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Merlin Solar Technologies Inc RFP-F036W185L,Merlin Solar Technologies Inc,Mono-c-Si,0,185.0,167.9,1.09,,,36.0,9.25,24.5,8.87,20.9,0.0049025,-0.06419,53.7,0.8894123865662059,9.25000079337147,1.0068030112026963e-11,0.08576826120678266,999999.5148871432,4.194168907281289,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc RFP-F036W185S,Merlin Solar Technologies Inc,Mono-c-Si,0,185.0,167.9,1.09,,,36.0,9.25,24.52,8.87,20.86,0.0049025,-0.0642424,53.69,0.8891123551534439,9.250000856942256,9.753002856085802e-12,0.09264062578629652,999999.4040825963,3.9244890051213974,-0.317,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc BR320,Merlin Solar Technologies Inc,Mono-c-Si,0,320.0,291.7,1.95,,,72.0,8.95,45.75,8.77,36.5,0.004296,-0.1422825,46.21,1.810732455473765,8.950153797586518,9.52319040139663e-11,0.24529104714553912,14274.332287086345,5.5010115654377145,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc BR325,Merlin Solar Technologies Inc,Mono-c-Si,0,325.0,296.4,1.95,,,72.0,9.05,45.8,8.87,36.7,0.004344000000000001,-0.14243799999999998,46.21,1.8165281807309381,9.05014012328679,1.0154633292644742e-10,0.22075731334748866,14257.846515164078,5.953043996212507,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc BR330,Merlin Solar Technologies Inc,Mono-c-Si,0,330.0,301.1,1.95,,,72.0,9.12,46.0,8.94,37.0,0.0043776,-0.14306,46.21,1.8277563698033323,9.12012865991001,1.0709148546170262e-10,0.2013078425785269,14269.634520175374,6.341675777303569,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc BR335,Merlin Solar Technologies Inc,Mono-c-Si,0,335.0,305.7,1.95,,,72.0,9.15,46.25,8.94,37.71,0.004392000000000001,-0.1438375,46.21,1.8462688581850353,9.150111018684775,1.2077270623686964e-10,0.1732355954380767,14277.848554221426,7.34785857777404,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Merlin Solar Technologies Inc BR340,Merlin Solar Technologies Inc,Mono-c-Si,0,340.0,310.4,1.95,,,72.0,9.18,46.5,8.95,38.41,0.0044063999999999996,-0.144615,46.21,1.8655686595075376,9.180100437108521,1.3731334548983413e-10,0.1326373910398007,12123.136283453076,8.434813721929153,-0.406,N,2025.7.3,6/23/2025,2.0,first_pass +Messisolar New Energy Co Ltd MS-48N-BH-450M,Messisolar New Energy Co Ltd,Mono-c-Si,1,450.0,423.6,1.98,,,32.0,16.05,35.03,14.97,30.08,0.0072225,-0.087575,46.0,1.2572761865086484,16.064794145793556,1.2333456958790411e-11,0.06097634102443763,66.15253682011664,6.413231478327502,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger Black 370W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,370.0,353.1,1.77,,,60.0,10.53,44.38,9.88,37.46,0.0043173,-0.104293,44.38,1.4568803107609383,10.545736393475304,6.038623177635421e-13,0.22152786223869725,148.2352601134611,-8.635338091294376,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MEYER BURGER GLASS 370W,Meyer Burger (Industries) GmbH,Mono-c-Si,1,370.0,353.0,1.73,,,60.0,10.4,44.5,9.9,37.7,0.0038480000000000003,-0.10413000000000001,44.79,1.443737942460644,10.406019348800873,4.227054264711878e-13,0.21247888560091066,367.11286949936914,-10.879848399559595,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger Black 375W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,375.0,358.0,1.77,,,60.0,10.6,44.5,9.9,38.0,0.004346,-0.104575,44.38,1.4716670924944175,10.614814980562356,7.561204548621317e-13,0.17030962348878978,121.85517224036414,-6.912543207460297,-0.248,N,2025.7.3,6/23/2025,4.0,bootstrapping +Meyer Burger (Industries) GmbH MEYER BURGER GLASS 375W,Meyer Burger (Industries) GmbH,Mono-c-Si,1,375.0,357.8,1.73,,,60.0,10.4,44.6,9.9,37.9,0.0038480000000000003,-0.10436400000000001,44.79,1.4489349927438786,10.405756440503794,4.405242884620389e-13,0.19986529566068456,361.0910373117699,-10.565431850127991,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger White 375W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,375.0,356.4,1.77,,,60.0,10.7,44.3,10.2,37.0,0.0038519999999999995,-0.103219,46.23,1.4251361498590231,10.706089596765606,3.355947173378683e-13,0.26472610285519266,465.14891060287545,-12.446798027615674,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger Black 380W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,380.0,362.8,1.77,,,60.0,10.6,44.6,10.0,38.2,0.004346,-0.10481,44.38,1.4702982459796068,10.60913081932999,6.947009940866278e-13,0.1590709876524518,184.66606442932465,-7.617980787756634,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MEYER BURGER GLASS 380W,Meyer Burger (Industries) GmbH,Mono-c-Si,1,380.0,362.7,1.73,,,60.0,10.5,44.7,10.0,38.1,0.0038849999999999996,-0.10459800000000002,44.79,1.4538279993331755,10.505269719473432,4.606598782974222e-13,0.18551945301375666,369.64989040248344,-10.299306372018506,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger White 380W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,380.0,361.3,1.77,,,60.0,10.8,44.4,10.3,37.2,0.003888,-0.103452,46.23,1.4300501867496662,10.805652414192625,3.51549243751812e-13,0.25013563511358505,477.931157858962,-12.169402018041852,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger Black 385W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,385.0,367.7,1.77,,,60.0,10.7,44.6,10.1,38.4,0.004387,-0.10481,44.38,1.4734139378031383,10.707790258786616,7.478898782067555e-13,0.135378887109534,185.9442788833315,-7.115814213506604,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MEYER BURGER GLASS 385W,Meyer Burger (Industries) GmbH,Mono-c-Si,1,385.0,367.6,1.73,,,60.0,10.6,44.7,10.1,38.2,0.003921999999999999,-0.10459800000000002,44.79,1.4551957800601403,10.604835857867265,4.78843094756442e-13,0.17269801522088646,378.54689117096177,-10.077639555123191,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger White 385W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,385.0,366.1,1.77,,,60.0,10.9,44.5,10.3,37.6,0.0039239999999999995,-0.10368500000000001,46.23,1.4442786646482504,10.911621879320718,4.4444135032771644e-13,0.21369380968182736,200.42047086867925,-10.423027103185817,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger Black 390W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,390.0,372.6,1.77,,,60.0,10.8,44.7,10.2,38.5,0.0044280000000000005,-0.10504500000000001,44.38,1.4765932795669388,10.80756170647183,7.534182103599918e-13,0.13298023196521985,189.92887566007428,-7.133317981648237,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger White 390W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,390.0,371.0,1.77,,,60.0,10.9,44.5,10.4,37.8,0.0039239999999999995,-0.10368500000000001,46.23,1.4721707788789773,10.900014811796108,8.124377743320854e-13,0.18557637034842375,136565.66357547723,-5.815619419667734,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger Black 395W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,395.0,377.4,1.77,,,60.0,10.9,44.7,10.3,38.7,0.004469,-0.10504500000000001,44.38,1.4871383879653823,10.906115326381506,9.428531033156488e-13,0.10829424625916113,193.0244128939658,-5.439857593958178,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger White 395W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,395.0,375.8,1.77,,,60.0,11.0,44.6,10.4,38.0,0.00396,-0.10391800000000001,46.23,1.452581580581843,11.009790176143532,4.992752217693165e-13,0.17812554090577895,200.1374563136714,-9.60313148999773,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH Meyer Burger White 400W,Meyer Burger (Industries) GmbH,Mono-c-Si,0,400.0,380.7,1.77,,,60.0,11.1,44.7,10.5,38.2,0.0039959999999999996,-0.10415100000000002,46.23,1.4574622216536388,11.10899864251361,5.215345643987772e-13,0.1646749919292759,203.12979517918575,-9.339009432154812,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C1S_540,Meyer Burger (Industries) GmbH,Mono-c-Si,1,540.0,511.6,2.62,,,72.0,12.7,53.4,11.9,45.3,0.00508,-0.12442200000000002,46.22,1.7801210047036062,12.717546126607502,1.1570269309376363e-12,0.19507503924279115,141.19657599586176,-4.162436906398114,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C2S_540,Meyer Burger (Industries) GmbH,Mono-c-Si,1,540.0,511.6,2.62,,,72.0,12.7,53.4,11.9,45.3,0.00508,-0.12442200000000002,46.22,1.7801210047036062,12.717546126607502,1.1570269309376363e-12,0.19507503924279115,141.19657599586176,-4.162436906398114,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C3S_540,Meyer Burger (Industries) GmbH,Mono-c-Si,1,540.0,511.6,2.62,,,72.0,12.7,53.4,11.9,45.3,0.00508,-0.12442200000000002,46.22,1.7801210047036062,12.717546126607502,1.1570269309376363e-12,0.19507503924279115,141.19657599586176,-4.162436906398114,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C4S_540,Meyer Burger (Industries) GmbH,Mono-c-Si,1,540.0,511.6,2.62,,,72.0,12.7,53.4,11.9,45.3,0.00508,-0.12442200000000002,46.22,1.7801210047036062,12.717546126607502,1.1570269309376363e-12,0.19507503924279115,141.19657599586176,-4.162436906398114,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_540,Meyer Burger (Industries) GmbH,Mono-c-Si,1,540.0,511.6,2.62,,,72.0,12.7,53.4,11.9,45.3,0.00508,-0.12442200000000002,46.22,1.7801210047036062,12.717546126607502,1.1570269309376363e-12,0.19507503924279115,141.19657599586176,-4.162436906398114,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C6S_540,Meyer Burger (Industries) GmbH,Mono-c-Si,1,540.0,511.6,2.62,,,72.0,12.7,53.4,11.9,45.3,0.00508,-0.12442200000000002,46.22,1.7801210047036062,12.717546126607502,1.1570269309376363e-12,0.19507503924279115,141.19657599586176,-4.162436906398114,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C1S_545,Meyer Burger (Industries) GmbH,Mono-c-Si,1,545.0,516.5,2.62,,,72.0,12.8,53.4,12.0,45.4,0.00512,-0.12442200000000002,46.22,1.7815050921344693,12.816542846297203,1.1941477477765186e-12,0.1841934116528834,142.5193480828708,-3.973056778070945,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C2S_545,Meyer Burger (Industries) GmbH,Mono-c-Si,1,545.0,516.5,2.62,,,72.0,12.8,53.4,12.0,45.4,0.00512,-0.12442200000000002,46.22,1.7815050921344693,12.816542846297203,1.1941477477765186e-12,0.1841934116528834,142.5193480828708,-3.973056778070945,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C3S_545,Meyer Burger (Industries) GmbH,Mono-c-Si,1,545.0,516.5,2.62,,,72.0,12.8,53.4,12.0,45.4,0.00512,-0.12442200000000002,46.22,1.7815050921344693,12.816542846297203,1.1941477477765186e-12,0.1841934116528834,142.5193480828708,-3.973056778070945,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C4S_545,Meyer Burger (Industries) GmbH,Mono-c-Si,1,545.0,516.5,2.62,,,72.0,12.8,53.4,12.0,45.4,0.00512,-0.12442200000000002,46.22,1.7815050921344693,12.816542846297203,1.1941477477765186e-12,0.1841934116528834,142.5193480828708,-3.973056778070945,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_545,Meyer Burger (Industries) GmbH,Mono-c-Si,1,545.0,516.5,2.62,,,72.0,12.8,53.4,12.0,45.4,0.00512,-0.12442200000000002,46.22,1.7815050921344693,12.816542846297203,1.1941477477765186e-12,0.1841934116528834,142.5193480828708,-3.973056778070945,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C6S_545,Meyer Burger (Industries) GmbH,Mono-c-Si,1,545.0,516.5,2.62,,,72.0,12.8,53.4,12.0,45.4,0.00512,-0.12442200000000002,46.22,1.7815050921344693,12.816542846297203,1.1941477477765186e-12,0.1841934116528834,142.5193480828708,-3.973056778070945,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C1S_550,Meyer Burger (Industries) GmbH,Mono-c-Si,1,550.0,521.3,2.62,,,72.0,12.9,53.4,12.1,45.5,0.0051600000000000005,-0.12442200000000002,46.22,1.7828912317639716,12.915557899047409,1.232372119392651e-12,0.17349303496017948,143.8536245388208,-3.7834312270563877,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C2S_550,Meyer Burger (Industries) GmbH,Mono-c-Si,1,550.0,521.3,2.62,,,72.0,12.9,53.4,12.1,45.5,0.0051600000000000005,-0.12442200000000002,46.22,1.7828912317639716,12.915557899047409,1.232372119392651e-12,0.17349303496017948,143.8536245388208,-3.7834312270563877,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C3S_550,Meyer Burger (Industries) GmbH,Mono-c-Si,1,550.0,521.3,2.62,,,72.0,12.9,53.4,12.1,45.5,0.0051600000000000005,-0.12442200000000002,46.22,1.7828912317639716,12.915557899047409,1.232372119392651e-12,0.17349303496017948,143.8536245388208,-3.7834312270563877,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C4S_550,Meyer Burger (Industries) GmbH,Mono-c-Si,1,550.0,521.3,2.62,,,72.0,12.9,53.4,12.1,45.5,0.0051600000000000005,-0.12442200000000002,46.22,1.7828912317639716,12.915557899047409,1.232372119392651e-12,0.17349303496017948,143.8536245388208,-3.7834312270563877,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_550,Meyer Burger (Industries) GmbH,Mono-c-Si,1,550.0,521.3,2.62,,,72.0,12.9,53.4,12.1,45.5,0.0051600000000000005,-0.12442200000000002,46.22,1.7828912317639716,12.915557899047409,1.232372119392651e-12,0.17349303496017948,143.8536245388208,-3.7834312270563877,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C6S_550,Meyer Burger (Industries) GmbH,Mono-c-Si,1,550.0,521.3,2.62,,,72.0,12.9,53.4,12.1,45.5,0.0051600000000000005,-0.12442200000000002,46.22,1.7828912317639716,12.915557899047409,1.232372119392651e-12,0.17349303496017948,143.8536245388208,-3.7834312270563877,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C1S_555,Meyer Burger (Industries) GmbH,Mono-c-Si,1,555.0,526.2,2.62,,,72.0,13.0,53.5,12.2,45.6,0.005200000000000001,-0.12465500000000002,46.22,1.7860841784081152,13.015244231756062,1.2395934943154912e-12,0.171174566443082,145.9745167131963,-3.8007619570176083,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C2S_555,Meyer Burger (Industries) GmbH,Mono-c-Si,1,555.0,526.2,2.62,,,72.0,13.0,53.5,12.2,45.6,0.005200000000000001,-0.12465500000000002,46.22,1.7860841784081152,13.015244231756062,1.2395934943154912e-12,0.171174566443082,145.9745167131963,-3.8007619570176083,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C3S_555,Meyer Burger (Industries) GmbH,Mono-c-Si,1,555.0,526.2,2.62,,,72.0,13.0,53.5,12.2,45.6,0.005200000000000001,-0.12465500000000002,46.22,1.7860841784081152,13.015244231756062,1.2395934943154912e-12,0.171174566443082,145.9745167131963,-3.8007619570176083,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C4S_555,Meyer Burger (Industries) GmbH,Mono-c-Si,1,555.0,526.2,2.62,,,72.0,13.0,53.5,12.2,45.6,0.005200000000000001,-0.12465500000000002,46.22,1.7860841784081152,13.015244231756062,1.2395934943154912e-12,0.171174566443082,145.9745167131963,-3.8007619570176083,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_555,Meyer Burger (Industries) GmbH,Mono-c-Si,1,555.0,526.2,2.62,,,72.0,13.0,53.5,12.2,45.6,0.005200000000000001,-0.12465500000000002,46.22,1.7860841784081152,13.015244231756062,1.2395934943154912e-12,0.171174566443082,145.9745167131963,-3.8007619570176083,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C6S_555,Meyer Burger (Industries) GmbH,Mono-c-Si,1,555.0,526.2,2.62,,,72.0,13.0,53.5,12.2,45.6,0.005200000000000001,-0.12465500000000002,46.22,1.7860841784081152,13.015244231756062,1.2395934943154912e-12,0.171174566443082,145.9745167131963,-3.8007619570176083,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C1S_560,Meyer Burger (Industries) GmbH,Mono-c-Si,1,560.0,531.0,2.62,,,72.0,13.1,53.5,12.3,45.7,0.005240000000000001,-0.12465500000000002,46.22,1.7874763633255077,13.114292078544477,1.2791309346830982e-12,0.16075430851868547,147.34605855537598,-3.6107406427842315,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C2S_560,Meyer Burger (Industries) GmbH,Mono-c-Si,1,560.0,531.0,2.62,,,72.0,13.1,53.5,12.3,45.7,0.005240000000000001,-0.12465500000000002,46.22,1.7874763633255077,13.114292078544477,1.2791309346830982e-12,0.16075430851868547,147.34605855537598,-3.6107406427842315,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C3S_560,Meyer Burger (Industries) GmbH,Mono-c-Si,1,560.0,531.0,2.62,,,72.0,13.1,53.5,12.3,45.7,0.005240000000000001,-0.12465500000000002,46.22,1.7874763633255077,13.114292078544477,1.2791309346830982e-12,0.16075430851868547,147.34605855537598,-3.6107406427842315,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C4S_560,Meyer Burger (Industries) GmbH,Mono-c-Si,1,560.0,531.0,2.62,,,72.0,13.1,53.5,12.3,45.7,0.005240000000000001,-0.12465500000000002,46.22,1.7874763633255077,13.114292078544477,1.2791309346830982e-12,0.16075430851868547,147.34605855537598,-3.6107406427842315,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_560,Meyer Burger (Industries) GmbH,Mono-c-Si,1,560.0,531.0,2.62,,,72.0,13.1,53.5,12.3,45.7,0.005240000000000001,-0.12465500000000002,46.22,1.7874763633255077,13.114292078544477,1.2791309346830982e-12,0.16075430851868547,147.34605855537598,-3.6107406427842315,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C6S_560,Meyer Burger (Industries) GmbH,Mono-c-Si,1,560.0,531.0,2.62,,,72.0,13.1,53.5,12.3,45.7,0.005240000000000001,-0.12465500000000002,46.22,1.7874763633255077,13.114292078544477,1.2791309346830982e-12,0.16075430851868547,147.34605855537598,-3.6107406427842315,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_565,Meyer Burger (Industries) GmbH,Mono-c-Si,1,565.0,535.8,2.62,,,72.0,13.2,53.5,12.4,45.8,0.00528,-0.12465500000000002,46.22,1.78887032434599,13.213357414895139,1.31983386149064e-12,0.1505035113027841,148.7298526895186,-3.420508818967719,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Meyer Burger (Industries) GmbH MB_WG144C5S_570,Meyer Burger (Industries) GmbH,Mono-c-Si,1,570.0,540.7,2.62,,,72.0,13.3,53.6,12.4,45.8,0.00532,-0.12488800000000001,46.22,1.7968848494370975,13.318583767422037,1.4249688159113293e-12,0.15634498657893245,111.89272199865816,-2.826809395054522,-0.259,N,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 120N,Miasole,CIGS,0,115.1,104.6,0.898,,,56.0,4.58,37.8,3.97,30.3,-5.038e-05,-0.0911736,48.2,1.3853145056349268,4.632809269665843,5.775894764303807e-12,0.8050731338255305,69.82173738861064,15.812315253986645,-0.3605,N,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 280NL,Miasole,CIGS,0,280.0,258.8,2.057,,,132.0,4.59,88.7,3.96,70.8,0.00028917,-0.2009942,45.35,3.215533070442129,4.649005848645752,4.269881934966544e-12,1.9942246497808265,155.12854002318198,20.208471797149134,-0.3464,N,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 290W,Miasole,CIGS,0,290.0,250.8,2.211,,,72.0,9.27,47.2,7.83,37.2,-0.0006674399999999999,-0.1676072,49.1,2.100358251767616,9.395842209991764,1.408236293531261e-09,0.4931252869960445,36.32542539189194,15.45786481196009,-0.5188,Y,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 300W,Miasole,CIGS,0,300.0,259.7,2.211,,,72.0,9.21,48.0,7.89,38.1,-0.0006631200000000001,-0.17044800000000002,49.1,2.125421131975779,9.311008826744766,1.2728348869971515e-09,0.46561455810745583,42.4548088590149,14.543025782483802,-0.5188,Y,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 310W,Miasole,CIGS,0,310.0,268.6,2.211,,,72.0,9.14,48.7,7.96,39.0,-0.00065808,-0.17293370000000002,49.1,2.1453809316872547,9.21513335203639,1.1465971287140522e-09,0.42666578743272615,51.90405456692863,13.604679347949915,-0.5188,Y,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 320W,Miasole,CIGS,0,320.0,277.6,2.211,,,72.0,9.08,49.5,8.02,40.0,-0.00065376,-0.1757745,49.1,2.1734405131191092,9.134982793405237,1.0740899074214993e-09,0.3855232613422778,63.66630849423627,13.023877128916501,-0.5188,Y,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 470W,Miasole,CIGS,0,470.0,412.4,3.0,,,112.0,9.19,74.8,7.91,59.6,0.00093738,-0.18513,62.9,2.603125883442494,9.319591865606574,2.696332623671548e-12,0.8866443027465135,62.87632842628703,0.17472895523034027,-0.31195,N,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 480W,Miasole,CIGS,0,480.0,421.5,3.0,,,112.0,9.15,75.6,7.95,60.5,0.0009333000000000002,-0.18711,62.9,2.6239202593914794,9.262341499837488,2.5124981460784714e-12,0.8602855315473096,70.06860891269497,-0.40191951650099333,-0.31195,N,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 490W,Miasole,CIGS,0,490.0,430.5,3.0,,,112.0,9.11,76.4,7.99,61.4,0.00092922,-0.18909000000000004,62.9,2.6446184904379133,9.206473463154119,2.3414403550940565e-12,0.8342820327430996,78.78134856397155,-0.9760689904694507,-0.31195,N,2025.7.3,6/23/2025,4.0,first_pass +Miasole FLEX-03 500W,Miasole,CIGS,0,500.0,439.6,3.0,,,112.0,9.07,77.2,8.03,62.4,0.0009251400000000001,-0.19107,62.9,2.6673991146177927,9.150428538160703,2.2341094620673718e-12,0.7942586523562769,89.56927450749991,-1.3569048648118798,-0.31195,Y,2025.7.3,6/23/2025,4.0,first_pass +Midsummer AB SLIM 2 x 10 65,Midsummer AB,Thin Film,0,65.0,53.6,0.65,,,20.0,7.7,12.6,6.7,10.2,0.0011396,-0.040383,61.06,0.518002660638545,7.76302350576641,1.892627180949385e-10,0.12427130858521493,15.183050723998987,10.239380343225562,-0.4331,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE260SO5T,Mission Solar Energy LLC,Mono-c-Si,0,260.0,234.9,1.609476,1.644,0.979,60.0,8.9,37.89,8.44,30.82,0.003827,-0.11821680000000001,47.49,1.501006929565356,8.901056231435165,9.678444935349795e-11,0.306417480465525,2581.931077149932,5.410610721259843,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE265SO5T,Mission Solar Energy LLC,Mono-c-Si,0,265.0,239.6,1.609476,1.644,0.979,60.0,8.99,38.07,8.53,31.14,0.0038657,-0.1187784,47.49,1.512317190143719,8.990958059110222,1.0483034381440463e-10,0.281070734472554,2637.443837664179,6.004127583454456,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE270SO5K,Mission Solar Energy LLC,Mono-c-Si,0,270.0,243.2,1.609476,1.644,0.979,60.0,9.28,37.64,8.78,30.79,0.0042688,-0.11743680000000001,48.26,1.5047275329579408,9.283021883319533,1.264385450772113e-10,0.2670524999468422,820.1003718729705,7.3141591082405375,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE270SO5T,Mission Solar Energy LLC,Mono-c-Si,0,270.0,244.2,1.609476,1.644,0.979,60.0,9.09,38.21,8.64,31.28,0.003908699999999999,-0.1192152,47.49,1.5178110482028342,9.090002739890192,1.060361598338835e-10,0.27553601633340513,914281.281795636,6.00224223759335,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE275SO5K,Mission Solar Energy LLC,Mono-c-Si,0,275.0,247.8,1.609476,1.644,0.979,60.0,9.34,37.82,8.89,30.95,0.0042964,-0.11799840000000002,48.26,1.5106600673178818,9.340002404677715,1.2519965559610482e-10,0.2574073444478274,999999.9703071181,7.157895483553572,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE275SO5T,Mission Solar Energy LLC,Mono-c-Si,0,275.0,248.9,1.609476,1.644,0.979,60.0,9.17,38.45,8.72,31.55,0.0039431,-0.11996400000000002,47.49,1.5292856916554711,9.170002726764153,1.1044269916508745e-10,0.2649724672128178,891232.632580116,6.275107271477598,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE280SO5K,Mission Solar Energy LLC,Mono-c-Si,0,280.0,252.5,1.609476,1.644,0.979,60.0,9.37,38.22,8.93,31.37,0.004310199999999999,-0.11924639999999999,48.26,1.52960109181352,9.370002279078365,1.3184454321888215e-10,0.2431827502915307,999999.8150056514,7.577120898542904,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE280SO5T,Mission Solar Energy LLC,Mono-c-Si,0,280.0,253.5,1.609476,1.644,0.979,60.0,9.27,38.6,8.79,31.87,0.003986099999999999,-0.120432,47.49,1.5417000316570895,9.271821274448719,1.236244359165274e-10,0.23702887003985332,1206.4398597822274,7.161243911923137,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE285SO5K,Mission Solar Energy LLC,Mono-c-Si,0,285.0,257.2,1.609476,1.644,0.979,60.0,9.42,38.62,8.98,31.77,0.004333200000000001,-0.1204944,48.26,1.5473946594407941,9.420002212731665,1.364246089946962e-10,0.23485107496446272,999999.9395190018,7.827033988072786,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE285SQ5K,Mission Solar Energy LLC,Mono-c-Si,0,285.0,262.7,1.609476,1.644,0.979,60.0,9.67,38.05,9.05,31.66,0.0044482,-0.10654000000000001,45.51,1.4742304998258746,9.681413202949477,5.846201178442409e-11,0.20598863381332153,174.52682787519615,12.143744484115684,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE285SQ5T,Mission Solar Energy LLC,Mono-c-Si,0,285.0,262.7,1.599,1.64,0.975,60.0,9.37,39.56,8.87,32.36,0.004310199999999999,-0.11076800000000002,45.51,1.5104431440473773,9.374462032723647,3.929853039805035e-11,0.29505942290963244,619.6070460232708,8.829197339786171,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE285SQ8T,Mission Solar Energy LLC,Mono-c-Si,0,285.0,262.1,1.6,,,60.0,9.367,39.69,8.72,32.68,0.00337212,-0.1115289,46.09,1.517258180172264,9.38424885226086,3.9720189164347545e-11,0.2709491199116315,147.13909025582294,8.740782082381218,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE290SB1A,Mission Solar Energy LLC,Mono-c-Si,0,290.0,258.8,1.9503,1.97,0.99,72.0,8.72,44.5,8.12,36.0,0.0016132000000000002,-0.14769549999999998,47.0,1.8298606333715839,8.734510573430898,2.343841967332678e-10,0.38022495399155554,228.49282207319334,6.893354182146423,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE290SQ5K,Mission Solar Energy LLC,Mono-c-Si,0,290.0,267.4,1.609476,1.644,0.979,60.0,9.7,39.08,9.12,31.89,0.004462,-0.10942400000000001,45.51,1.495174689086655,9.710611849579069,4.2588751193942383e-11,0.291176575992492,266.15651020162835,9.259873635932678,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE290SQ5T,Mission Solar Energy LLC,Mono-c-Si,0,290.0,267.4,1.599,1.64,0.975,60.0,9.44,39.81,8.95,32.54,0.0043424,-0.11146800000000001,45.51,1.518266578608841,9.44320022197116,3.850607048832146e-11,0.29793931343677305,878.8600681103645,8.578348266895564,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE290SQ8K,Mission Solar Energy LLC,Mono-c-Si,0,290.0,266.7,1.6,,,60.0,9.561,39.0,8.982,32.3,0.00430245,-0.10920000000000002,46.43,1.4948366916741738,9.570859436674548,4.390167075560668e-11,0.23574642751043406,228.6105893392592,9.679484726726173,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE290SQ8T,Mission Solar Energy LLC,Mono-c-Si,0,290.0,266.9,1.6,,,60.0,9.42,39.91,8.811,32.91,0.0033912,-0.1121471,46.09,1.5232225960134054,9.433588357008075,3.8511528935306206e-11,0.2648615020864993,183.61273386239185,8.401564000302322,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE60A290,Mission Solar Energy LLC,Mono-c-Si,0,290.0,266.1,1.627,,,60.0,9.62,39.77,9.06,32.0,0.003848,-0.11931000000000001,44.58,1.5712623604212808,9.627340405234149,9.707870375162008e-11,0.342447118018945,448.7956020514584,9.054593276658517,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE295SB1A,Mission Solar Energy LLC,Mono-c-Si,0,295.0,263.4,1.9503,1.97,0.99,72.0,8.79,44.8,8.19,36.3,0.0016261499999999998,-0.14869119999999997,47.0,1.8432799744484383,8.803934568540237,2.397909772881871e-10,0.371539545781899,234.3691410892169,7.0186553183354325,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE295SQ5K,Mission Solar Energy LLC,Mono-c-Si,0,295.0,272.1,1.609476,1.644,0.979,60.0,9.73,39.38,9.2,32.19,0.0044758,-0.11026400000000001,45.51,1.5038686077321668,9.735641915393085,4.096723245262762e-11,0.28568168220914186,492.68425054187566,8.868000030364241,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE295SQ5T,Mission Solar Energy LLC,Mono-c-Si,0,295.0,272.2,1.599,1.64,0.975,60.0,9.52,40.11,9.03,32.72,0.0043792,-0.11230800000000002,45.51,1.5277853702730815,9.522765775547642,3.760033906279458e-11,0.30604094611631505,1053.4140982494916,8.29389478168494,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE295SQ8K,Mission Solar Energy LLC,Mono-c-Si,0,295.0,271.5,1.6,,,60.0,9.578,39.24,9.027,32.68,0.004310099999999999,-0.10987200000000001,46.43,1.5060055834170905,9.585182077000997,4.56544785685444e-11,0.21386841788875616,285.21439465768947,9.999045032371622,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE295SQ8T,Mission Solar Energy LLC,Mono-c-Si,0,295.0,271.6,1.6,,,60.0,9.48,40.07,8.912,33.1,0.0034128,-0.11259670000000001,46.09,1.5268851862678128,9.489796491125512,3.738060639883541e-11,0.25709397817424645,248.78814641605564,8.065270526322452,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE60A295,Mission Solar Energy LLC,Mono-c-Si,0,295.0,270.4,1.627,,,60.0,9.77,40.11,9.15,32.24,0.0041034,-0.1131102,46.67,1.530069215334997,9.785671253536337,3.960261725042655e-11,0.35782532897941155,223.0806574585144,7.8432896838665584,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE300MC1A,Mission Solar Energy LLC,Multi-c-Si,0,300.0,264.1,1.9503,1.97,0.99,72.0,8.78,44.5,8.31,36.0,0.003997534,-0.168744,48.2,1.9241980434040915,8.793381913624893,7.951237757911688e-10,0.3511260048062081,999999.9560843117,2.7286577069271933,-0.4936,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE300SB1A,Mission Solar Energy LLC,Mono-c-Si,0,300.0,268.0,1.9503,1.97,0.99,72.0,8.86,45.2,8.26,36.6,0.0016390999999999999,-0.15001879999999998,47.0,1.8584653773723139,8.873658940826768,2.378940012883055e-10,0.37537866420844795,243.4929000233176,6.879950405912986,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE300SQ5K,Mission Solar Energy LLC,Mono-c-Si,0,300.0,276.9,1.609476,1.644,0.979,60.0,9.77,39.72,9.27,32.38,0.004494199999999999,-0.11121600000000001,45.51,1.512175681637393,9.772530671083352,3.8102073963986693e-11,0.2980465018654471,1150.6491693435298,8.181140576060768,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE300SQ5T,Mission Solar Energy LLC,Mono-c-Si,0,300.0,276.9,1.599,1.64,0.975,60.0,9.61,40.18,9.17,32.8,0.004420599999999999,-0.112504,45.51,1.5304920399235102,9.610002788025048,3.8123327461604685e-11,0.2900964289647678,999999.7860507271,8.318510289142193,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE300SQ8K,Mission Solar Energy LLC,Mono-c-Si,0,300.0,276.2,1.6,,,60.0,9.652,39.66,9.104,32.95,0.0043434,-0.111048,46.43,1.5195932284465299,9.658952158487732,4.4104802524444064e-11,0.22472520122005776,311.9962940762444,9.62057180390709,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE300SQ8T,Mission Solar Energy LLC,Mono-c-Si,0,300.0,276.3,1.6,,,60.0,9.571,40.08,9.058,33.12,0.00344556,-0.11262480000000001,46.09,1.522509168909835,9.576059506144961,3.504260291513163e-11,0.2537350687849902,479.98724378254036,7.392663728983826,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE300TS60,Mission Solar Energy LLC,Mono-c-Si,0,300.0,271.4,1.62,,,60.0,9.83,40.0,9.31,32.6,0.0031456,-0.1152,48.9,1.5442514379968335,9.833605568408608,5.510458452028953e-11,0.2946609714679432,803.3455401323918,8.462091823724371,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE60A300,Mission Solar Energy LLC,Mono-c-Si,0,300.0,275.1,1.627,,,60.0,9.91,40.45,9.24,32.48,0.0041622000000000004,-0.11406899999999999,46.67,1.5455351056335254,9.930945213767378,4.169229983689515e-11,0.3601251937774448,170.3893201772202,8.18489238767737,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305MC1A,Mission Solar Energy LLC,Multi-c-Si,0,305.0,268.7,1.9503,1.97,0.99,72.0,8.94,44.7,8.42,36.2,0.004070382,-0.16950240000000003,48.2,1.9377454266083194,8.942723752709076,8.534967133506834e-10,0.3411502983949829,1119.737170560149,3.192457300756556,-0.4936,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305SB1A,Mission Solar Energy LLC,Mono-c-Si,0,305.0,272.6,1.9503,1.97,0.99,72.0,8.94,45.6,8.32,36.9,0.0016538999999999998,-0.1513464,47.0,1.8759723680848008,8.955325951536583,2.428748882097393e-10,0.37856143320241664,220.82410197424494,6.9872688900099895,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305SE1A,Mission Solar Energy LLC,Mono-c-Si,0,305.0,276.3,1.8798359999999998,1.946,0.966,72.0,8.93,45.6,8.32,36.9,0.003572,-0.14136,47.25,1.8003960230568767,8.94672102725875,8.738001925874055e-11,0.39784469811919043,212.4721893117069,5.3031964438017996,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305SE1J,Mission Solar Energy LLC,Mono-c-Si,0,305.0,276.1,1.8798359999999998,1.946,0.966,72.0,8.93,45.6,8.32,36.9,0.0034827,-0.139992,47.25,1.8056680004409964,8.946549270385846,9.410077459739698e-11,0.396505350409878,213.95462258975434,6.985121678110886,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305SQ5K,Mission Solar Energy LLC,Mono-c-Si,0,305.0,281.6,1.609476,1.644,0.979,60.0,9.81,39.95,9.36,32.61,0.0045126,-0.11186000000000001,45.51,1.5216255906834033,9.810002778008178,3.884593885638411e-11,0.28316056071720974,999999.7921490641,8.302588849747343,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE305SQ8K,Mission Solar Energy LLC,Mono-c-Si,0,305.0,280.9,1.6,,,60.0,9.723,39.96,9.238,33.02,0.00437535,-0.11188800000000002,46.43,1.5213238871970791,9.725124710938022,3.792116890280677e-11,0.24792286528422255,1134.5327642365935,8.195160622584602,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305SQ8T,Mission Solar Energy LLC,Mono-c-Si,0,305.0,281.1,1.6,,,60.0,9.664,40.1,9.202,33.14,0.00347904,-0.11268100000000002,46.09,1.5188400309761136,9.664664182703154,3.3004221612460355e-11,0.25140889056745136,3658.053756953936,6.7652266727247605,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE305TS60,Mission Solar Energy LLC,Mono-c-Si,0,305.0,276.0,1.62,,,60.0,9.9,40.1,9.38,32.8,0.0031680000000000002,-0.115488,48.9,1.5507690248405783,9.9033806879047,5.801980276909919e-11,0.2786476776333336,815.9913956605013,8.85020501880894,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE60A305,Mission Solar Energy LLC,Mono-c-Si,0,305.0,279.8,1.627,,,60.0,10.06,40.79,9.32,32.73,0.004225200000000001,-0.11502779999999999,46.67,1.562860561440461,10.08866517756547,4.516888916348568e-11,0.360842944890785,126.6372786276713,8.779548953032291,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310MC1A,Mission Solar Energy LLC,Multi-c-Si,0,310.0,273.2,1.9503,1.97,0.99,72.0,9.08,44.9,8.52,36.4,0.004134124,-0.1702608,48.2,1.951633829806171,9.085690375456227,9.177958017670582e-10,0.3316527144543253,529.2108250178516,3.6838241396163416,-0.4936,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310SB1A,Mission Solar Energy LLC,Mono-c-Si,0,310.0,277.2,1.9503,1.97,0.99,72.0,9.01,45.9,8.39,37.2,0.0016668499999999999,-0.15234209999999998,47.0,1.8893915467700095,9.024739175648648,2.483200055754493e-10,0.37009716452406827,226.23895510191915,7.1089471451740165,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310SE1A,Mission Solar Energy LLC,Mono-c-Si,0,310.0,281.0,1.8798359999999998,1.946,0.966,72.0,8.96,45.6,8.38,37.0,0.0035840000000000004,-0.14136,47.25,1.7995534393941328,8.97311035438572,8.700890729058001e-11,0.3826602015252086,261.52119423539693,5.225122590641193,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310SE1J,Mission Solar Energy LLC,Mono-c-Si,0,310.0,280.7,1.8798359999999998,1.946,0.966,72.0,8.96,45.6,8.38,37.0,0.0034944000000000004,-0.139992,47.25,1.8048207106986363,8.972953272923371,9.370148822055995e-11,0.3813299549599105,263.77244951449285,6.9058073727992815,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310SQ8K,Mission Solar Energy LLC,Mono-c-Si,0,310.0,285.7,1.6,,,60.0,9.819,40.09,9.362,33.11,0.00441855,-0.11225200000000002,46.43,1.5241814765015265,9.819003161368572,3.706574575763395e-11,0.24849314973073758,771838.9651435819,7.897973712292449,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310SQ8T,Mission Solar Energy LLC,Mono-c-Si,0,310.0,285.8,1.6,,,60.0,9.76,40.12,9.345,33.17,0.0035136,-0.11273720000000001,46.09,1.522268603663691,9.760002238195279,3.4949644360116e-11,0.2293110469675908,999998.9633822805,7.169836400047801,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE310SR8T,Mission Solar Energy LLC,Mono-c-Si,0,310.0,284.8,1.64,,,60.0,9.967,40.14,9.202,33.69,0.004584820000000001,-0.11078640000000002,47.15,1.4723408018796877,9.987797288269599,1.382011402514725e-11,0.1967800320833297,94.30585457884378,1.079500889262346,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE310TS60,Mission Solar Energy LLC,Mono-c-Si,0,310.0,280.7,1.62,,,60.0,9.94,40.3,9.45,33.1,0.0031808,-0.11606399999999999,48.9,1.559291654481738,9.940729513031318,5.923175469177335e-11,0.2622940794849009,3573.8941132476534,8.98260684658954,-0.403,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE60A310,Mission Solar Energy LLC,Mono-c-Si,0,310.0,284.5,1.627,,,60.0,10.21,41.14,9.4,32.97,0.004288200000000001,-0.11601479999999999,46.67,1.5801446300041346,10.246719024124177,4.851605404137792e-11,0.3638594647081243,101.17385398589458,9.302147962853088,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315MC1A,Mission Solar Energy LLC,Multi-c-Si,0,315.0,277.8,1.9503,1.97,0.99,72.0,9.18,45.1,8.61,36.6,0.004179654,-0.17101919999999998,48.2,1.9620273826208923,9.186075723319904,9.459690118804838e-10,0.3242201029102739,489.874540509,3.8477475720576924,-0.4936,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315SB1A,Mission Solar Energy LLC,Mono-c-Si,0,315.0,281.8,1.9503,1.97,0.99,72.0,9.08,46.3,8.45,37.5,0.0016798,-0.15366969999999996,47.0,1.9057802523776137,9.095459749274124,2.498406807132834e-10,0.3737649732285921,219.52401474160058,7.097101705780823,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315SE1A,Mission Solar Energy LLC,Mono-c-Si,0,315.0,285.7,1.8798359999999998,1.946,0.966,72.0,8.99,45.8,8.47,37.2,0.0035960000000000002,-0.14198,47.25,1.8017340540154894,8.996867804528241,8.125588598638184e-11,0.3781075988325661,494.94529490979227,4.59144220487637,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315SE1J,Mission Solar Energy LLC,Mono-c-Si,0,315.0,285.4,1.8798359999999998,1.946,0.966,72.0,8.99,45.8,8.47,37.2,0.0035061000000000003,-0.14060599999999998,47.25,1.8070059278438715,8.996732589457867,8.75245105283329e-11,0.37679140156575786,503.128099493193,6.263880790297381,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315SQ8K,Mission Solar Energy LLC,Mono-c-Si,0,315.0,290.4,1.6,,,60.0,9.917,40.13,9.465,33.28,0.004462649999999999,-0.11236400000000002,46.43,1.529116115834116,9.917003026436257,3.9699840064147347e-11,0.22945316129230717,751903.9411958585,8.410620213960044,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315SR8K,Mission Solar Energy LLC,Mono-c-Si,0,315.0,290.8,1.64,,,60.0,9.963,40.14,9.352,33.68,0.00408483,-0.11038500000000002,45.98,1.5406606514681298,9.972040725032684,4.730722891820461e-11,0.18101417290819116,199.48004381781038,12.050700692131489,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE315SR8T,Mission Solar Energy LLC,Mono-c-Si,0,315.0,289.5,1.64,,,60.0,9.997,40.44,9.253,34.04,0.00459862,-0.1116144,47.15,1.572202128302929,10.012072123056418,6.505172491039498e-11,0.16439417808833898,109.03895922818145,14.51284758780586,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE60A315,Mission Solar Energy LLC,Mono-c-Si,0,315.0,289.3,1.627,,,60.0,10.37,41.49,9.48,33.22,0.004355400000000001,-0.1170018,46.67,1.5985152743907116,10.416080416926041,5.295077376455113e-11,0.36525024420087304,82.19641507968973,9.96499849398678,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320MC1A,Mission Solar Energy LLC,Multi-c-Si,0,320.0,282.4,1.9503,1.97,0.99,72.0,9.26,45.3,8.69,36.8,0.004216078,-0.17177759999999997,48.2,1.9713142261785255,9.265666930071884,9.612966468502678e-10,0.31776833875766397,519.2470175435225,3.9083565614482194,-0.4936,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320MM4J,Mission Solar Energy LLC,Multi-c-Si,0,320.0,295.0,1.926,,,72.0,9.24,45.18,8.69,36.88,0.0048972,-0.1368954,44.57,1.766036295022966,9.248820657941012,7.074602449070594e-11,0.34253059003877007,358.8148185890189,5.449153864834648,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320MM6J,Mission Solar Energy LLC,Multi-c-Si,0,320.0,295.0,1.926,,,72.0,9.24,45.18,8.69,36.88,0.0048972,-0.1368954,44.57,1.766036295022966,9.248820657941012,7.074602449070594e-11,0.34253059003877007,358.8148185890189,5.449153864834648,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SB1A,Mission Solar Energy LLC,Mono-c-Si,0,320.0,286.4,1.9503,1.97,0.99,72.0,9.15,46.7,8.52,37.8,0.0016927500000000002,-0.1549973,47.0,1.9209624580531213,9.16519075327393,2.47903174979614e-10,0.3774703715870517,227.3655638834742,6.961853877114554,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SE1A,Mission Solar Energy LLC,Mono-c-Si,0,320.0,290.3,1.8798359999999998,1.946,0.966,72.0,9.12,45.9,8.56,37.4,0.0036479999999999998,-0.14229,47.25,1.81228509903473,9.12996757477441,9.001170810702285e-11,0.3571864250374082,326.8137469033757,5.3503945403420525,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SE1J,Mission Solar Energy LLC,Mono-c-Si,0,320.0,290.0,1.8798359999999998,1.946,0.966,72.0,9.12,45.9,8.56,37.4,0.0035567999999999997,-0.140913,47.25,1.81758664953319,9.129824571260361,9.692771873632133e-11,0.3558724519814663,330.350997734575,7.032344164510527,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SO4J,Mission Solar Energy LLC,Mono-c-Si,0,320.0,288.2,1.925693,1.967,0.979,72.0,8.97,45.68,8.51,37.65,0.0043953,-0.143892,48.26,1.8370298452444278,8.971119910705104,1.421168637391098e-10,0.2952431970306108,2364.771182211796,7.539657389841896,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SO6J,Mission Solar Energy LLC,Mono-c-Si,0,320.0,287.9,1.925693,1.967,0.979,72.0,8.97,45.68,8.51,37.65,0.0043953,-0.143892,48.26,1.8427244922164525,8.971024113456284,1.5349364432380196e-10,0.293824174854834,2573.546991681506,8.20816916720913,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SO6W,Mission Solar Energy LLC,Multi-c-Si,0,320.0,290.9,1.9850130000000001,1.987,0.999,72.0,8.92,46.13,8.49,37.71,0.004014,-0.14346430000000002,46.38,1.8276088339917815,8.920003024235001,9.738589009627739e-11,0.338993287418821,999999.9756277964,5.755416607770477,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE320SR8K,Mission Solar Energy LLC,Mono-c-Si,0,320.0,295.5,1.64,,,60.0,9.988,40.38,9.435,33.92,0.00409508,-0.11104500000000002,45.98,1.5458491259422737,9.993539555700876,4.464381232559255e-11,0.1778833184479108,320.7294432022209,11.478066476263992,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE320SR8T,Mission Solar Energy LLC,Mono-c-Si,0,320.0,294.2,1.64,,,60.0,10.028,40.8,9.351,34.22,0.004612880000000001,-0.112608,47.15,1.5770352570585295,10.040543137314902,5.671260621285299e-11,0.18199233254357036,145.4994139765142,13.190990061346188,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325MC1A,Mission Solar Energy LLC,Multi-c-Si,0,325.0,286.9,1.9503,1.97,0.99,72.0,9.32,45.7,8.76,37.0,0.004243396,-0.1732944,48.2,1.9829987850946647,9.32448926839639,9.075087139642195e-10,0.33566278009809614,696.8573194427638,3.36439674223678,-0.4936,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325MM4J,Mission Solar Energy LLC,Multi-c-Si,0,325.0,299.7,1.926,,,72.0,9.26,45.8,8.72,37.3,0.0049078,-0.13877399999999998,44.57,1.7868785000182072,9.267894929599587,6.765701390068086e-11,0.3580554365590018,419.96492229225413,5.045965955094024,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325MM6J,Mission Solar Energy LLC,Multi-c-Si,0,325.0,299.7,1.926,,,72.0,9.26,45.8,8.72,37.3,0.0049078,-0.13877399999999998,44.57,1.7868785000182072,9.267894929599587,6.765701390068086e-11,0.3580554365590018,419.96492229225413,5.045965955094024,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SB1A,Mission Solar Energy LLC,Mono-c-Si,0,325.0,291.0,1.9503,1.97,0.99,72.0,9.23,47.0,8.59,38.1,0.00170755,-0.155993,47.0,1.9355046369457756,9.245540109033408,2.568785925446237e-10,0.3687212727119464,219.00087917954082,7.1951671943777935,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SE1A,Mission Solar Energy LLC,Mono-c-Si,0,325.0,295.0,1.8798359999999998,1.946,0.966,72.0,9.13,46.1,8.6,37.8,0.0036520000000000003,-0.14291,47.25,1.8231374400576887,9.136820049808849,9.422062270781993e-11,0.3264081140545382,436.9625202464778,5.71732829272592,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SE1J,Mission Solar Energy LLC,Mono-c-Si,0,325.0,294.7,1.8798359999999998,1.946,0.966,72.0,9.13,46.1,8.6,37.8,0.0035607000000000004,-0.14152700000000001,47.25,1.8284669270477099,9.136696837009383,1.0144248498011041e-10,0.32508808982691395,443.20243107647434,7.403517191195908,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SO4J,Mission Solar Energy LLC,Mono-c-Si,0,325.0,292.8,1.925693,1.967,0.979,72.0,9.08,45.79,8.62,37.72,0.0044492,-0.1442385,48.26,1.840283965551383,9.080676425404006,1.4172196111947848e-10,0.2952476154025374,3963.2598415179236,7.407260920240258,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SO6J,Mission Solar Energy LLC,Mono-c-Si,0,325.0,292.6,1.925693,1.967,0.979,72.0,9.08,45.79,8.62,37.72,0.0044492,-0.1442385,48.26,1.845986937602173,9.080580580240728,1.5307103604503766e-10,0.29384542049018775,4595.606614079982,8.075170783565293,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SO6W,Mission Solar Energy LLC,Multi-c-Si,0,325.0,295.6,1.9850130000000001,1.987,0.999,72.0,9.06,46.39,8.6,37.84,0.004077,-0.1442729,46.38,1.8350748935980319,9.06056585114286,9.505257047058779e-11,0.35531073073658487,5688.983235502371,5.419761022195157,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SR8K,Mission Solar Energy LLC,Mono-c-Si,0,325.0,300.3,1.64,,,60.0,10.024,40.8,9.499,34.21,0.00410984,-0.11220000000000001,45.98,1.5579868148936262,10.027958655984515,4.210371257316932e-11,0.18718641346408654,473.98830878302215,10.90564174455428,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE325SR8T,Mission Solar Energy LLC,Mono-c-Si,0,325.0,299.0,1.64,,,60.0,10.06,41.14,9.387,34.62,0.0046276,-0.1135464,47.15,1.5924356954627408,10.071382490284712,5.904702137718322e-11,0.16889325168273828,149.27015560212337,13.529157538136802,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330MM4J,Mission Solar Energy LLC,Multi-c-Si,0,330.0,304.4,1.926,,,72.0,9.33,46.01,8.81,37.5,0.0049449,-0.1394103,44.57,1.7933708611262398,9.335617703200759,6.674141559766311e-11,0.3532724536191297,586.7223812439809,4.8566615407697045,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330MM6J,Mission Solar Energy LLC,Multi-c-Si,0,330.0,304.4,1.926,,,72.0,9.33,46.01,8.81,37.5,0.0049449,-0.1394103,44.57,1.7933708611262398,9.335617703200759,6.674141559766311e-11,0.3532724536191297,586.7223812439809,4.8566615407697045,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SB1A,Mission Solar Energy LLC,Mono-c-Si,0,330.0,295.6,1.9503,1.97,0.99,72.0,9.3,47.4,8.65,38.4,0.0017205000000000002,-0.15732059999999998,47.0,1.9518947243774336,9.316263840266764,2.5839712395803607e-10,0.37231318545153747,212.89639083555386,7.183005253822658,-0.4647,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SE1A,Mission Solar Energy LLC,Mono-c-Si,0,330.0,299.7,1.8798359999999998,1.946,0.966,72.0,9.14,46.11,8.62,37.5,0.0036560000000000004,-0.142941,47.25,1.8142822245641221,9.146104047855886,8.310845428773696e-11,0.36792644182489076,550.9209632890099,4.638426956704876,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SE1J,Mission Solar Energy LLC,Mono-c-Si,0,330.0,299.4,1.8798359999999998,1.946,0.966,72.0,9.14,46.11,8.62,37.5,0.0035646000000000002,-0.1415577,47.25,1.819589945453003,9.145971492604042,8.951762374442235e-11,0.3666233429586866,561.1557852280471,6.311371268228946,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SO4J,Mission Solar Energy LLC,Mono-c-Si,0,330.0,297.4,1.925693,1.967,0.979,72.0,9.23,46.12,8.72,37.85,0.0045227,-0.145278,48.26,1.8543451865388296,9.233990155740464,1.4484011388042509e-10,0.3109218392873492,719.222292880018,7.471608611377466,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SO6J,Mission Solar Energy LLC,Mono-c-Si,0,330.0,297.2,1.925693,1.967,0.979,72.0,9.23,46.12,8.72,37.85,0.0045227,-0.145278,48.26,1.8600937739072854,9.23387180736248,1.5643784086951192e-10,0.3095270971194088,737.8816298848183,8.139834832161004,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SO6W,Mission Solar Energy LLC,Multi-c-Si,0,330.0,300.2,1.9850130000000001,1.987,0.999,72.0,9.12,46.62,8.64,38.38,0.004103999999999999,-0.1449882,46.38,1.8552798813887534,9.122411864431,1.109478405918217e-10,0.3070706316359768,1161.1285348967288,6.694616454366719,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SO7J,Mission Solar Energy LLC,Mono-c-Si,0,330.0,302.1,1.91,,,72.0,9.325,45.85,8.816,37.43,0.004009749999999999,-0.1370915,45.79,1.7904857653672797,9.329530578434444,7.008135582156197e-11,0.34360987905499357,707.2303051247742,6.814089582927122,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SO9J,Mission Solar Energy LLC,Mono-c-Si,0,330.0,302.1,1.91,,,72.0,9.325,45.85,8.816,37.43,0.004009749999999999,-0.1370915,45.79,1.7904857653672797,9.329530578434444,7.008135582156197e-11,0.34360987905499357,707.2303051247742,6.814089582927122,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SR8K,Mission Solar Energy LLC,Mono-c-Si,0,330.0,305.0,1.64,,,60.0,10.045,41.06,9.556,34.53,0.00411845,-0.11291500000000002,45.98,1.5672870863762156,10.04677812933703,4.193093215601118e-11,0.17623391754834405,995.5798784300242,10.83366091550088,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE330SX5T,Mission Solar Energy LLC,Mono-c-Si,0,330.0,307.0,1.787,,,60.0,10.72,40.4,10.05,32.85,0.0041808,-0.105848,44.43,1.4980911081338724,10.736908092334078,2.0425733004832408e-11,0.2958989524523749,187.60465318412582,9.303990715676596,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SB1A,Mission Solar Energy LLC,Mono-c-Si,0,335.0,294.2,1.9503,1.97,0.99,72.0,9.32,47.6,8.71,38.7,0.00120228,-0.1731688,48.1,2.0690310994348846,9.329009765852536,9.373857627575118e-10,0.32874760533291014,340.06752389695083,8.439894467911493,-0.5198,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SE1A,Mission Solar Energy LLC,Mono-c-Si,0,335.0,304.3,1.8798359999999998,1.946,0.966,72.0,9.15,46.4,8.68,38.9,0.0036600000000000005,-0.14384,47.25,1.8505448385217667,9.151927716245472,1.1748222373397231e-10,0.21407996167941262,1016.1411870900681,7.570124535766145,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SE1J,Mission Solar Energy LLC,Mono-c-Si,0,335.0,304.0,1.8798359999999998,1.946,0.966,72.0,9.15,46.4,8.68,38.9,0.0035685000000000005,-0.142448,47.25,1.8506913323610295,9.150004921858816,1.1527325313403985e-10,0.21898498177261053,407270.20251042454,7.196152973240077,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SO4J,Mission Solar Energy LLC,Mono-c-Si,0,335.0,302.1,1.925693,1.967,0.979,72.0,9.38,46.14,8.87,37.89,0.004596200000000001,-0.145341,48.26,1.8548948948195754,9.383376063744908,1.4684525667627075e-10,0.303076073069485,842.0617112388655,7.447637614305198,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SO6J,Mission Solar Energy LLC,Mono-c-Si,0,335.0,301.9,1.925693,1.967,0.979,72.0,9.38,46.14,8.87,37.89,0.004596200000000001,-0.145341,48.26,1.8606446429522832,9.383259748791808,1.5860409325135145e-10,0.30170427373672637,868.1608959388207,8.115749640572911,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SO7J,Mission Solar Energy LLC,Mono-c-Si,0,335.0,306.8,1.91,,,72.0,9.41,46.05,8.904,37.62,0.0040463,-0.1376895,45.79,1.7982148048933138,9.413871079740867,7.070469502586454e-11,0.3385395341926971,822.9376592380745,6.808987324637516,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SO9J,Mission Solar Energy LLC,Mono-c-Si,0,335.0,306.8,1.91,,,72.0,9.41,46.05,8.904,37.62,0.0040463,-0.1376895,45.79,1.7982148048933138,9.413871079740867,7.070469502586454e-11,0.3385395341926971,822.9376592380745,6.808987324637516,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SQ6W,Mission Solar Energy LLC,Multi-c-Si,0,335.0,306.3,1.9850130000000001,1.987,0.999,72.0,9.35,47.88,8.68,38.82,0.0036465,-0.1378944,46.13,1.8637749333005005,9.371499442265703,6.335978427901299e-11,0.3966184861438888,172.48740077110992,10.122886710956822,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SX5K,Mission Solar Energy LLC,Mono-c-Si,0,335.0,310.1,1.787,,,60.0,10.85,40.35,10.19,32.89,0.0053165,-0.105717,45.86,1.51093121236058,10.864350733511941,2.6934609012073976e-11,0.2798255555886233,211.56460835033653,11.527516087781688,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE335SX5T,Mission Solar Energy LLC,Mono-c-Si,0,335.0,311.8,1.787,,,60.0,10.78,40.58,10.14,33.03,0.0042042,-0.1063196,44.43,1.5031725427273335,10.793359063159308,2.0037680414861526e-11,0.2916901994038729,235.37731243808125,9.070906753699028,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SO4J,Mission Solar Energy LLC,Mono-c-Si,0,340.0,306.7,1.925693,1.967,0.979,72.0,9.49,46.35,8.95,38.02,0.0046501,-0.1460025,48.26,1.864760837393009,9.495403896512373,1.5095394304387515e-10,0.30617326138070516,537.6832343519818,7.595751173039495,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SO6J,Mission Solar Energy LLC,Mono-c-Si,0,340.0,306.5,1.925693,1.967,0.979,72.0,9.49,46.35,8.95,38.02,0.0046501,-0.1460025,48.26,1.870543715812462,9.495275820400618,1.6303760925582121e-10,0.30480625052168897,548.2770754896785,8.2645508096572,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SO7J,Mission Solar Energy LLC,Mono-c-Si,0,340.0,311.6,1.91,,,72.0,9.505,46.21,9.002,37.77,0.00408715,-0.1381679,45.79,1.804150060028267,9.508176208636185,7.117405182460749e-11,0.3338729300033574,999.1352786453746,6.77602485045137,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SO9J,Mission Solar Energy LLC,Mono-c-Si,0,340.0,311.6,1.91,,,72.0,9.505,46.21,9.002,37.77,0.00408715,-0.1381679,45.79,1.804150060028267,9.508176208636185,7.117405182460749e-11,0.3338729300033574,999.1352786453746,6.77602485045137,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SQ6S,Mission Solar Energy LLC,Mono-c-Si,0,340.0,313.3,1.925693,1.967,0.979,72.0,9.67,46.57,8.93,38.25,0.0044482,-0.130396,45.51,1.80415870442184,9.693995761676748,5.747500180347437e-11,0.3148907174802327,126.89712828451391,12.040328288544593,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SQ6W,Mission Solar Energy LLC,Multi-c-Si,0,340.0,311.0,1.9850130000000001,1.987,0.999,72.0,9.39,47.96,8.79,38.96,0.0036621000000000006,-0.1381248,46.13,1.8610191167975132,9.403766164325189,5.924820673744473e-11,0.3858169486517549,263.16853089202135,9.458771728880981,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SX5K,Mission Solar Energy LLC,Mono-c-Si,0,340.0,314.8,1.787,,,60.0,10.91,40.53,10.28,33.06,0.005345900000000001,-0.10618860000000001,45.86,1.5158565735839817,10.921001697570603,2.633092716037999e-11,0.27691883685556784,274.61076506517793,11.259332359167262,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE340SX5T,Mission Solar Energy LLC,Mono-c-Si,0,340.0,316.6,1.787,,,60.0,10.86,40.82,10.24,33.2,0.0042354,-0.10694840000000001,44.43,1.5097567234812779,10.870936051658218,1.9427786248174766e-11,0.29408710150458467,292.0419602654811,8.722177330512055,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SO4J,Mission Solar Energy LLC,Mono-c-Si,0,345.0,311.4,1.925693,1.967,0.979,72.0,9.52,46.52,9.05,38.14,0.0046648,-0.14653800000000003,48.26,1.8641560356493048,9.52741111179483,1.3840673390996845e-10,0.30932644792712666,999999.9852989533,6.784672416410658,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE345SO6J,Mission Solar Energy LLC,Mono-c-Si,0,345.0,311.2,1.925693,1.967,0.979,72.0,9.52,46.52,9.05,38.14,0.0046648,-0.14653800000000003,48.26,1.8709046895467678,9.520003725240267,1.5132566802244225e-10,0.30792795467221823,787043.3858974465,7.56118688726338,-0.421,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SO7J,Mission Solar Energy LLC,Mono-c-Si,0,345.0,316.3,1.91,,,72.0,9.583,46.47,9.082,37.99,0.00412069,-0.1389453,45.79,1.8138858354893608,9.58564881748419,7.139391551682653e-11,0.3320947409413484,1201.4660615857442,6.729605741411543,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SO9J,Mission Solar Energy LLC,Mono-c-Si,0,345.0,316.3,1.91,,,72.0,9.583,46.47,9.082,37.99,0.00412069,-0.1389453,45.79,1.8138858354893608,9.58564881748419,7.139391551682653e-11,0.3320947409413484,1201.4660615857442,6.729605741411543,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SQ4S,Mission Solar Energy LLC,Mono-c-Si,0,345.0,318.1,1.913925,1.963,0.975,72.0,9.7,46.98,9.04,38.43,0.004462,-0.13154400000000002,45.51,1.807627012125625,9.71782600112455,4.883491519852907e-11,0.3376766177670412,183.7463785421869,10.51093259289995,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SQ6S,Mission Solar Energy LLC,Mono-c-Si,0,345.0,318.1,1.925693,1.967,0.979,72.0,9.7,46.98,9.04,38.43,0.004462,-0.13154400000000002,45.51,1.807627012125625,9.71782600112455,4.883491519852907e-11,0.3376766177670412,183.7463785421869,10.51093259289995,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SQ6W,Mission Solar Energy LLC,Multi-c-Si,0,345.0,315.7,1.9850130000000001,1.987,0.999,72.0,9.42,48.06,8.87,39.0,0.0036738,-0.1384128,46.13,1.858435325170351,9.428584201845531,5.472660503759576e-11,0.39093311485438614,428.9962137274972,8.708696441181246,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SX5K,Mission Solar Energy LLC,Mono-c-Si,0,345.0,319.6,1.787,,,60.0,10.97,40.71,10.38,33.24,0.0053753,-0.10666020000000001,45.86,1.5203530821245235,10.976735918414944,2.5578342381506814e-11,0.2729423509622884,444.509193194645,10.931111649082613,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE345SX5T,Mission Solar Energy LLC,Mono-c-Si,0,345.0,321.4,1.787,,,60.0,10.92,41.0,10.34,33.37,0.0042588,-0.10742000000000002,44.43,1.5139803940373717,10.926457227314183,1.879561416138833e-11,0.29105276155895676,492.207578921039,8.364593188884747,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE350SO7J,Mission Solar Energy LLC,Mono-c-Si,0,350.0,321.0,1.91,,,72.0,9.681,46.69,9.183,38.14,0.004162829999999999,-0.13960309999999998,45.79,1.8209142657593267,9.682898767301516,7.063899130785219e-11,0.3341152565701584,1703.5104196431619,6.547057790595025,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE350SO9J,Mission Solar Energy LLC,Mono-c-Si,0,350.0,321.0,1.91,,,72.0,9.681,46.69,9.183,38.14,0.004162829999999999,-0.13960309999999998,45.79,1.8209142657593267,9.682898767301516,7.063899130785219e-11,0.3341152565701584,1703.5104196431619,6.547057790595025,-0.401,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE350SQ4S,Mission Solar Energy LLC,Mono-c-Si,0,350.0,322.9,1.913925,1.963,0.975,72.0,9.73,47.38,9.11,38.68,0.0044758,-0.13266400000000003,45.51,1.816889921308053,9.744265800202003,4.5130968263848895e-11,0.34960784785767646,238.45029241977053,9.762564320881518,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE350SQ6S,Mission Solar Energy LLC,Mono-c-Si,0,350.0,322.8,1.925693,1.967,0.979,72.0,9.73,47.38,9.11,38.68,0.0044758,-0.13266400000000003,45.51,1.816889921308053,9.744265800202003,4.5130968263848895e-11,0.34960784785767646,238.45029241977053,9.762564320881518,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE350SX5K,Mission Solar Energy LLC,Mono-c-Si,0,350.0,324.4,1.787,,,60.0,11.05,40.95,10.48,33.41,0.005414500000000001,-0.10728900000000001,45.86,1.5270540486830966,11.054383860853852,2.483262792123526e-11,0.2754297066121116,694.2506768479071,10.589897653097523,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE350SX5T,Mission Solar Energy LLC,Mono-c-Si,0,350.0,326.1,1.79,,,60.0,10.97,41.18,10.44,33.52,0.0042783000000000005,-0.1078916,44.43,1.5171606425691457,10.97104693306734,1.7854204344612496e-11,0.29051342929466395,3044.065383471809,7.852055863747854,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-350120BW,Mission Solar Energy LLC,Mono-c-Si,0,350.0,326.6,1.82,,,60.0,11.01,41.1,10.42,33.6,0.00742074,-0.1156965,43.2,1.591840883293153,11.014763101425208,6.70089661089196e-11,0.2583585858951836,597.2008520298954,11.275384061479969,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-350120BB,Mission Solar Energy LLC,Mono-c-Si,0,350.0,326.6,1.8,,,60.0,11.04,40.2,10.48,33.4,0.00525504,-0.1056054,45.6,2.0140779537431475,11.040061527612233,7.13070340386032e-13,3.1751741165966223,981421.0938300953,98.05799610214105,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE355SQ4S,Mission Solar Energy LLC,Mono-c-Si,0,355.0,327.6,1.913925,1.963,0.975,72.0,9.76,47.68,9.19,38.98,0.0044896,-0.133504,45.51,1.8246649246753621,9.769251695326638,4.320237580699125e-11,0.3439946912271142,362.8943805724649,9.326227730827393,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE355SQ6S,Mission Solar Energy LLC,Mono-c-Si,0,355.0,327.5,1.925693,1.967,0.979,72.0,9.76,47.68,9.19,38.98,0.0044896,-0.133504,45.51,1.8246649246753621,9.769251695326638,4.320237580699125e-11,0.3439946912271142,362.8943805724649,9.326227730827393,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE355SQ7S,Mission Solar Energy LLC,Mono-c-Si,0,355.0,326.8,1.91,,,72.0,9.62,47.44,9.058,39.2,0.0043289999999999995,-0.132832,46.43,1.81408865965594,9.628587541775229,4.167721928147289e-11,0.29677030772458,332.45024991178656,9.155525298795224,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE355SQ9S,Mission Solar Energy LLC,Mono-c-Si,0,355.0,326.8,1.91,,,72.0,9.62,47.44,9.058,39.2,0.0043289999999999995,-0.132832,46.43,1.81408865965594,9.628587541775229,4.167721928147289e-11,0.29677030772458,332.45024991178656,9.155525298795224,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE355SX5K,Mission Solar Energy LLC,Mono-c-Si,0,355.0,329.1,1.79,,,60.0,11.1,40.99,10.59,33.51,0.005439,-0.10739380000000001,45.86,1.5279326155934168,11.100004467389585,2.48004489550988e-11,0.2667167312164273,662725.5865444095,10.519249456437239,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-355120BB,Mission Solar Energy LLC,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007467920000000001,-0.11625949999999999,43.2,1.5987418878060913,11.082655311072475,6.66908404780848e-11,0.254018124528891,1059.959109625431,11.16681125367441,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-355120BW,Mission Solar Energy LLC,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007467920000000001,-0.11625949999999999,43.2,1.5987418878060913,11.082655311072475,6.66908404780848e-11,0.254018124528891,1059.959109625431,11.16681125367441,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-355120BB,Mission Solar Energy LLC,Mono-c-Si,0,355.0,331.3,1.8,,,60.0,11.14,40.4,10.57,33.6,0.005302640000000001,-0.10613079999999998,45.6,1.473281921991184,11.145387633112634,1.362471094732904e-11,0.20981556708502197,433.8352972095964,5.008578423496884,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE360SQ4S,Mission Solar Energy LLC,Mono-c-Si,0,360.0,332.3,1.913925,1.963,0.975,72.0,9.79,48.08,9.28,39.28,0.004503399999999999,-0.13462400000000002,45.51,1.8333605007332956,9.793477923731832,3.9752316664669224e-11,0.34942856330660127,983.6057108243948,8.539086498136736,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE360SQ6S,Mission Solar Energy LLC,Mono-c-Si,0,360.0,332.3,1.925693,1.967,0.979,72.0,9.79,48.08,9.28,39.28,0.004503399999999999,-0.13462400000000002,45.51,1.8333605007332956,9.793477923731832,3.9752316664669224e-11,0.34942856330660127,983.6057108243948,8.539086498136736,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE360SQ7S,Mission Solar Energy LLC,Mono-c-Si,0,360.0,331.5,1.91,,,72.0,9.661,47.83,9.143,39.38,0.00434745,-0.13392400000000002,46.43,1.8210007881659545,9.666042871000624,3.754976265768342e-11,0.31641898101495197,606.1872045494482,8.180537153899708,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE360SQ9S,Mission Solar Energy LLC,Mono-c-Si,0,360.0,331.5,1.91,,,72.0,9.661,47.83,9.143,39.38,0.00434745,-0.13392400000000002,46.43,1.8210007881659545,9.666042871000624,3.754976265768342e-11,0.31641898101495197,606.1872045494482,8.180537153899708,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-360120BB,Mission Solar Energy LLC,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.0075151,-0.1168225,43.2,1.6063866847452126,11.151507243277342,6.710118392710772e-11,0.24971156911102335,1847.2692831374839,11.160560710349037,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-360120BW,Mission Solar Energy LLC,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.0075151,-0.1168225,43.2,1.6063866847452126,11.151507243277342,6.710118392710772e-11,0.24971156911102335,1847.2692831374839,11.160560710349037,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-360120BB,Mission Solar Energy LLC,Mono-c-Si,0,360.0,336.1,1.8,,,60.0,11.24,40.6,10.66,33.8,0.00535024,-0.1066562,45.6,1.4816311464731258,11.245759911271026,1.4009413512411609e-11,0.20532944544121465,400.6837743157577,5.172555015029031,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE365SQ4S,Mission Solar Energy LLC,Mono-c-Si,0,365.0,337.1,1.913925,1.963,0.975,72.0,9.81,48.12,9.32,39.32,0.0045126,-0.134736,45.51,1.8330736647066006,9.811503489633008,3.891673866619317e-11,0.34815240867262354,2271.6323016057,8.325762755993386,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE365SQ6S,Mission Solar Energy LLC,Mono-c-Si,0,365.0,337.0,1.925693,1.967,0.979,72.0,9.81,48.12,9.32,39.32,0.0045126,-0.134736,45.51,1.8330736647066006,9.811503489633008,3.891673866619317e-11,0.34815240867262354,2271.6323016057,8.325762755993386,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE365SQ7S,Mission Solar Energy LLC,Mono-c-Si,0,365.0,336.2,1.91,,,72.0,9.705,48.05,9.236,39.52,0.00436725,-0.13454000000000002,46.43,1.8220667901773082,9.705007073503133,3.420938479722476e-11,0.32224034727670414,442130.5181361292,7.302764298598712,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE365SQ9S,Mission Solar Energy LLC,Mono-c-Si,0,365.0,336.2,1.91,,,72.0,9.705,48.05,9.236,39.52,0.00436725,-0.13454000000000002,46.43,1.8220667901773082,9.705007073503133,3.420938479722476e-11,0.32224034727670414,442130.5181361292,7.302764298598712,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-365120BB,Mission Solar Energy LLC,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007562280000000001,-0.1173855,43.2,1.6140377871100615,11.220004328233308,6.755129283530156e-11,0.2453763124568138,636129.253602014,11.157966857761727,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-365120BW,Mission Solar Energy LLC,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007562280000000001,-0.1173855,43.2,1.6140377871100615,11.220004328233308,6.755129283530156e-11,0.2453763124568138,636129.253602014,11.157966857761727,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-365120BB,Mission Solar Energy LLC,Mono-c-Si,0,365.0,340.9,1.8,,,60.0,11.33,40.8,10.74,34.0,0.005393080000000001,-0.10718159999999999,45.6,1.4900134809289745,11.336148031356695,1.4396076855716024e-11,0.20109307987581124,370.5876697902402,5.339875345190043,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE370SQ7S,Mission Solar Energy LLC,Mono-c-Si,0,370.0,341.0,1.91,,,72.0,9.767,48.08,9.323,39.69,0.00439515,-0.13462400000000002,46.43,1.8284585595021627,9.767003975277762,3.7138387855543376e-11,0.3016178316965489,741083.0172983615,7.961301128204087,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE370SQ9S,Mission Solar Energy LLC,Mono-c-Si,0,370.0,341.0,1.91,,,72.0,9.767,48.08,9.323,39.69,0.00439515,-0.13462400000000002,46.43,1.8284585595021627,9.767003975277762,3.7138387855543376e-11,0.3016178316965489,741083.0172983615,7.961301128204087,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-370120BB,Mission Solar Energy LLC,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.00760946,-0.11794849999999998,43.2,1.623333945636469,11.290004300440746,6.967589700101727e-11,0.24090660789441073,632499.5698948535,11.380881482322765,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-370120BW,Mission Solar Energy LLC,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.00760946,-0.11794849999999998,43.2,1.623333945636469,11.290004300440746,6.967589700101727e-11,0.24090660789441073,632499.5698948535,11.380881482322765,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-370120BB,Mission Solar Energy LLC,Mono-c-Si,0,370.0,345.7,1.8,,,60.0,11.42,41.0,10.82,34.2,0.00543592,-0.107707,45.6,1.498395366915929,11.426518712918089,1.4789209792441286e-11,0.1969197696451449,344.97972458377575,5.505503606241051,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE375SQ7S,Mission Solar Energy LLC,Mono-c-Si,0,375.0,345.7,1.91,,,72.0,9.826,48.16,9.432,39.76,0.004421700000000001,-0.134848,46.43,1.8361139913428868,9.826002598424173,3.9914516788745766e-11,0.26442748171257524,999986.4044316196,8.538534619527118,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE375SQ9S,Mission Solar Energy LLC,Mono-c-Si,0,375.0,345.7,1.91,,,72.0,9.826,48.16,9.432,39.76,0.004421700000000001,-0.134848,46.43,1.8361139913428868,9.826002598424173,3.9914516788745766e-11,0.26442748171257524,999986.4044316196,8.538534619527118,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE375SR9S,Mission Solar Energy LLC,Mono-c-Si,0,375.0,346.5,1.96,,,72.0,9.939,48.02,9.36,40.06,0.00427377,-0.13157480000000002,45.98,1.8295852851665884,9.947089407694262,3.909162110898632e-11,0.2474223856219304,303.99396560604,10.725216825409367,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE375SX5R,Mission Solar Energy LLC,Mono-c-Si,0,375.0,349.8,1.93,,,66.0,10.8524064279155,44.6392865497076,10.2575429458435,36.558462585034,0.0035812941212121155,-0.11561575216374269,43.75,1.6558558702571602,10.860526325035012,2.1055785699282143e-11,0.29322626715542943,391.902841557279,10.784794533363137,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-375120BB,Mission Solar Energy LLC,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.007656639999999999,-0.1185115,43.2,1.6326281749146987,11.36000427162938,7.184212125694039e-11,0.2365031656918171,629002.3785413279,11.601406904317031,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-375120BW,Mission Solar Energy LLC,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.007656639999999999,-0.1185115,43.2,1.6326281749146987,11.36000427162938,7.184212125694039e-11,0.2365031656918171,629002.3785413279,11.601406904317031,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-375120BB,Mission Solar Energy LLC,Mono-c-Si,0,375.0,350.5,1.8,,,60.0,11.51,41.2,10.91,34.4,0.00547876,-0.1082324,45.6,1.5061200464221607,11.51617749277998,1.5024945715303958e-11,0.19287948793638807,359.37604516910204,5.572316050950646,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE380SQ7S,Mission Solar Energy LLC,Mono-c-Si,0,380.0,350.5,1.91,,,72.0,9.904,48.17,9.552,39.78,0.0044568,-0.13487600000000002,46.43,1.8411259437973795,9.904192741075986,4.295855733492039e-11,0.23339223873863194,11992.866436480099,9.115939059407328,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE380SQ9S,Mission Solar Energy LLC,Mono-c-Si,0,380.0,350.5,1.91,,,72.0,9.904,48.17,9.552,39.78,0.0044568,-0.13487600000000002,46.43,1.8411259437973795,9.904192741075986,4.295855733492039e-11,0.23339223873863194,11992.866436480099,9.115939059407328,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSE380SR9S,Mission Solar Energy LLC,Mono-c-Si,0,380.0,351.2,1.96,,,72.0,9.966,48.31,9.385,40.49,0.004285379999999999,-0.13236940000000003,45.98,1.8451355243977439,9.973559875826561,4.1768535587064255e-11,0.2251152869369025,296.76399857611653,11.296250200440094,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE380SX5R,Mission Solar Energy LLC,Mono-c-Si,0,380.0,354.6,1.93,,,66.0,10.9127590449954,44.836514619883,10.3410969930474,36.7465850340136,0.0036012104848484826,-0.11612657286549698,43.75,1.6617727701602194,10.918419098249199,2.075869598524167e-11,0.2899609612254341,559.0537803674843,10.5964102551909,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE380SX9R,Mission Solar Energy LLC,Mono-c-Si,0,380.0,352.5,1.95,,,66.0,11.11,44.65,10.5,36.18,0.0037773999999999998,-0.11564350000000001,45.65,1.6340543619399197,11.119149653371142,1.4954336423481127e-11,0.3318229470042951,402.9172027639015,7.539029780141942,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE385SR9S,Mission Solar Energy LLC,Mono-c-Si,0,385.0,356.0,1.96,,,72.0,9.993,48.53,9.426,40.84,0.00429699,-0.1329722,45.98,1.8559119213283715,9.999200155035059,4.337566344869701e-11,0.2055610925789771,331.3097842914617,11.605594099095624,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE385SX5R,Mission Solar Energy LLC,Mono-c-Si,0,385.0,359.4,1.93,,,66.0,10.9741175390266,45.0337426900585,10.4237998954581,36.9347074829932,0.0036214587878787784,-0.11663739356725153,43.75,1.6678426876009063,10.977538648474102,2.0516073239097737e-11,0.2867125542569714,919.7067286387986,10.430575040338288,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE385SX9R,Mission Solar Energy LLC,Mono-c-Si,0,385.0,357.3,1.95,,,66.0,11.15,44.78,10.58,36.38,0.0037910000000000005,-0.1159802,45.65,1.6379390253283928,11.154619688524022,1.4856633430881188e-11,0.3211050696270262,775.0136397004717,7.433676929922192,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE390HT0B,Mission Solar Energy LLC,Mono-c-Si,0,390.0,364.7,1.9,,,54.0,13.59,36.78,12.76,30.57,0.0039411,-0.0923178,45.52,1.314263660312191,13.608422497658955,9.335393305965289e-12,0.16363286483177136,120.70950820387621,5.198831241347383,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE390SR9S,Mission Solar Energy LLC,Mono-c-Si,0,390.0,360.7,1.96,,,72.0,10.024,48.96,9.499,41.05,0.004310319999999999,-0.13415040000000003,45.98,1.8644884653531852,10.02804498405897,3.919069428909623e-11,0.22603626182634262,560.1474585725583,10.646037046790884,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE390SX5R,Mission Solar Energy LLC,Mono-c-Si,0,390.0,364.2,1.93,,,66.0,11.0143526170799,45.1652280701754,10.523440674998,37.0601224489796,0.0036347363636363675,-0.1169779407017543,43.75,1.6719745467120413,11.014357443746908,2.043209586633154e-11,0.2840125936067551,648125.8414933542,10.344698859548613,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE390SX9R,Mission Solar Energy LLC,Mono-c-Si,0,390.0,362.1,1.95,,,66.0,11.19,45.04,10.63,36.68,0.0038046000000000004,-0.11665360000000001,45.65,1.6485806667144007,11.19347896234191,1.5208675659756138e-11,0.3121549333873682,1004.0389843517745,7.6024174107926665,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE395HT0B,Mission Solar Energy LLC,Mono-c-Si,0,395.0,369.5,1.9,,,54.0,13.67,36.94,12.84,30.77,0.0039643000000000005,-0.09271940000000001,45.52,1.3211541984854829,13.687611626699024,9.628989466554351e-12,0.15742606706807735,122.19288794143178,5.413160387241303,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE395SR9S,Mission Solar Energy LLC,Mono-c-Si,0,395.0,365.5,1.96,,,72.0,10.045,49.28,9.532,41.44,0.00431935,-0.13502720000000001,45.98,1.8782400476833687,10.04818007218903,4.019544233202464e-11,0.2125641557348506,671.4335004254732,10.848483639252144,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE395SX9R,Mission Solar Energy LLC,Mono-c-Si,0,395.0,366.9,1.95,,,66.0,11.24,45.18,10.68,36.99,0.0038216,-0.1170162,45.65,1.6579030322653734,11.243480708187992,1.636632906926755e-11,0.29059933737926164,938.4115158516178,8.20594047298258,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE400HT0B,Mission Solar Energy LLC,Mono-c-Si,0,400.0,374.3,1.9,,,54.0,13.75,37.09,12.92,30.96,0.003987500000000001,-0.09309590000000001,45.52,1.3066322420243355,13.750004099441034,6.470323331912951e-12,0.15468758709652378,518843.4336804843,2.8884603380836755,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE400SR9S,Mission Solar Energy LLC,Mono-c-Si,0,400.0,370.2,1.96,,,72.0,10.067,49.46,9.61,41.62,0.00432881,-0.1355204,45.98,1.8802442234439374,10.06703608400794,3.790603515475459e-11,0.21049894661091498,58726.69092346412,10.278995480638027,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE400SX9R,Mission Solar Energy LLC,Mono-c-Si,0,400.0,371.6,1.95,,,66.0,11.31,45.33,10.79,37.07,0.0038454000000000006,-0.1174047,45.65,1.6604704485100383,11.310005307077533,1.5755827796217828e-11,0.2941167149970154,626808.8917518716,7.80334741333499,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-400108BB,Mission Solar Energy LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE405SX6S,Mission Solar Energy LLC,Mono-c-Si,0,405.0,376.8,2.136,,,72.0,10.89,48.56,10.23,39.59,0.0047916,-0.1267416,44.69,1.8055984908542193,10.904561004835712,2.238215200451913e-11,0.33733642588521473,252.2898514613771,10.325099838581576,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE405SX6W,Mission Solar Energy LLC,Mono-c-Si,0,405.0,376.8,2.136,,,72.0,10.89,48.56,10.23,39.59,0.0047916,-0.1267416,44.69,1.8055984908542193,10.904561004835712,2.238215200451913e-11,0.33733642588521473,252.2898514613771,10.325099838581576,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE405SX6Z,Mission Solar Energy LLC,Mono-c-Si,0,405.0,375.9,2.124,,,72.0,10.811165472910927,48.5539649122807,10.18992437530552,39.74514285714285,0.004648801153351699,-0.12672584842105264,46.08,1.780353714916654,10.822686303179282,1.5269473133186563e-11,0.32715606203466613,307.0037656383705,7.023932003818112,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-405108BB,Mission Solar Energy LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE410HT0B,Mission Solar Energy LLC,Mono-c-Si,0,410.0,383.9,1.9,,,54.0,13.9,37.41,13.07,31.38,0.004031000000000001,-0.0938991,45.52,1.3418793498411954,13.915167613541048,1.0629780278925804e-11,0.1377247749374577,126.21466110509802,6.118598413601379,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE410SX6S,Mission Solar Energy LLC,Mono-c-Si,0,410.0,381.6,2.136,,,72.0,10.93,48.71,10.32,39.73,0.0048092,-0.12713310000000003,44.69,1.807237818488529,10.939303967516535,2.1312110892823936e-11,0.33514639668228496,393.7191446959197,9.833407497484211,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE410SX6W,Mission Solar Energy LLC,Mono-c-Si,0,410.0,381.6,2.136,,,72.0,10.93,48.71,10.32,39.73,0.0048092,-0.12713310000000003,44.69,1.807237818488529,10.939303967516535,2.1312110892823936e-11,0.33514639668228496,393.7191446959197,9.833407497484211,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE410SX6Z,Mission Solar Energy LLC,Mono-c-Si,0,410.0,380.7,2.124,,,72.0,10.852406427915518,48.69740350877193,10.280337485723175,39.88195918367347,0.004666534764003673,-0.12710022315789474,46.08,1.781862418040194,10.858987256937436,1.455751632235494e-11,0.32472162054339637,535.4965211062582,6.555168194463883,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-410108BB,Mission Solar Energy LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE415SX6S,Mission Solar Energy LLC,Mono-c-Si,0,415.0,386.4,2.136,,,72.0,10.99,48.92,10.39,39.93,0.0048356,-0.12768120000000002,44.69,1.814596708689974,10.998000494329357,2.132247980830031e-11,0.33155818205010934,455.4499176368036,9.78365525515136,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE415SX6W,Mission Solar Energy LLC,Mono-c-Si,0,415.0,386.4,2.136,,,72.0,10.99,48.92,10.39,39.93,0.0048356,-0.12768120000000002,44.69,1.814596708689974,10.998000494329357,2.132247980830031e-11,0.33155818205010934,455.4499176368036,9.78365525515136,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE415SX6Z,Mission Solar Energy LLC,Mono-c-Si,0,415.0,385.4,2.124,,,72.0,10.91275904499541,48.912561403508775,10.352435915188934,40.08718367346939,0.004692486389348026,-0.1276617852631579,46.08,1.7891853089074108,10.917952106963638,1.4539555662367442e-11,0.32113044621219655,674.8271566752192,6.490467846974098,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE415SX9Z,Mission Solar Energy LLC,Mono-c-Si,0,415.0,386.8,2.14,,,72.0,11.11,48.71,10.51,39.5,0.004888399999999999,-0.1251847,44.75,1.7870063362644262,11.11789625289559,1.6005887760526827e-11,0.3577185845636365,503.308796355573,8.840188357847685,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-415HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,415.0,390.8,1.94,,,54.0,13.99,38.0,13.26,31.3,0.00602969,-0.0912,46.13,1.303216973415595,14.001757945447348,3.0038702685136143e-12,0.19627894077710184,233.53930318946357,-0.2095207872447483,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE420SX6S,Mission Solar Energy LLC,Mono-c-Si,0,420.0,391.2,2.136,,,72.0,11.05,49.14,10.46,40.14,0.004862,-0.12825540000000002,44.69,1.8223729215912432,11.056723219310548,2.134751280793633e-11,0.32788141895682343,538.8920967662744,9.740360478876184,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE420SX6W,Mission Solar Energy LLC,Mono-c-Si,0,420.0,391.2,2.136,,,72.0,11.05,49.14,10.46,40.14,0.004862,-0.12825540000000002,44.69,1.8223729215912432,11.056723219310548,2.134751280793633e-11,0.32788141895682343,538.8920967662744,9.740360478876184,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE420SX6Z,Mission Solar Energy LLC,Mono-c-Si,0,420.0,390.2,2.124,,,72.0,10.974117539026631,49.127719298245616,10.4237998954581,40.29240816326531,0.004718870541781451,-0.12822334736842106,46.08,1.7966480274965475,10.978111215343832,1.4551370511877574e-11,0.31755709877690497,872.6067728132642,6.443739366206198,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE420SX9Z,Mission Solar Energy LLC,Mono-c-Si,0,420.0,391.5,2.14,,,72.0,11.15,48.85,10.58,39.69,0.004906,-0.1255445,44.75,1.7913716561483606,11.15449011596928,1.592978526956133e-11,0.34899300496418856,866.6306481500203,8.753668273912485,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-420HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,420.0,395.6,1.94,,,54.0,14.07,38.1,13.34,31.5,0.006064170000000001,-0.09144,46.13,1.308767574817138,14.081162974994456,3.167271279206075e-12,0.1856315798283976,233.97314191631614,0.18185129946048154,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-420144BB,Mission Solar Energy LLC,Mono-c-Si,0,420.0,390.9,2.15,,,72.0,11.04,49.1,10.45,40.2,0.00660192,-0.1285929,46.8,1.7862185814478435,11.04777888760494,1.262075364393253e-11,0.3253807295919181,461.78880185160074,4.591309908817196,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-420144BW,Mission Solar Energy LLC,Mono-c-Si,0,420.0,391.9,2.15,,,72.0,11.04,49.1,10.45,40.2,0.00484656,-0.1272181,45.7,1.7669227313663183,11.048338516596193,9.34306858273053e-12,0.3294376431043958,436.1676156869479,3.3875514450350677,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE425SX6S,Mission Solar Energy LLC,Mono-c-Si,0,425.0,395.9,2.136,,,72.0,11.09,49.28,10.55,40.27,0.0048795999999999996,-0.1286208,44.69,1.8237175689883878,11.091663818692517,2.035730100123918e-11,0.32590926975196294,2172.311871320549,9.264974810891047,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE425SX6W,Mission Solar Energy LLC,Mono-c-Si,0,425.0,395.9,2.136,,,72.0,11.09,49.28,10.55,40.27,0.0048795999999999996,-0.1286208,44.69,1.8237175689883878,11.091663818692517,2.035730100123918e-11,0.32590926975196294,2172.311871320549,9.264974810891047,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE425SX6Z,Mission Solar Energy LLC,Mono-c-Si,0,425.0,395.0,2.124,,,72.0,11.01435261707989,49.271157894736845,10.512197682823901,40.42922448979592,0.004736171625344353,-0.12859772210526316,46.08,1.7993979356320424,11.014358123919399,1.4128435666464326e-11,0.31504857360741056,630145.1885079499,6.139492163938627,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE425SX9Z,Mission Solar Energy LLC,Mono-c-Si,0,425.0,396.3,2.14,,,72.0,11.19,49.14,10.62,40.01,0.004923599999999999,-0.1262898,44.75,1.8037466921411078,11.194375318685031,1.641323436454715e-11,0.34064514262683815,871.2095106552746,8.986266000693055,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-425HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,425.0,400.5,1.94,,,54.0,14.15,38.2,13.42,31.7,0.006098650000000001,-0.09168000000000001,46.13,1.3143130264386662,14.160567614498259,3.337751921024712e-12,0.17511691169143115,234.4809516897516,0.5702510706187484,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-425144BW,Mission Solar Energy LLC,Mono-c-Si,0,425.0,396.7,2.18,,,72.0,11.03,49.3,10.48,40.6,0.00743422,-0.13877949999999997,43.2,1.9131439527302476,11.031439843422156,7.084955696102789e-11,0.27669412368002905,2119.6311822532284,11.748970303621768,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-425144BB,Mission Solar Energy LLC,Mono-c-Si,0,425.0,395.7,2.15,,,72.0,11.11,49.3,10.52,40.4,0.006643779999999999,-0.1291167,46.8,1.7940076659055357,11.117445552358475,1.2805222970125893e-11,0.32068239949774335,478.51137503160794,4.660117830252568,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-425144BW,Mission Solar Energy LLC,Mono-c-Si,0,425.0,396.7,2.15,,,72.0,11.11,49.3,10.52,40.4,0.004877289999999999,-0.1277363,45.7,1.7746190521706322,11.117998847763046,9.479167300714959e-12,0.32473412557861603,451.03948353018706,3.4550207296165842,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE430SX9Z,Mission Solar Energy LLC,Mono-c-Si,0,430.0,401.1,2.14,,,72.0,11.24,49.28,10.66,40.32,0.0049456,-0.1266496,44.75,1.813876877059355,11.245264543440479,1.774643559613143e-11,0.31892774227630344,680.9228449638914,9.644650704180428,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-430HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,430.0,405.3,1.94,,,54.0,14.23,38.3,13.5,31.9,0.0061331300000000005,-0.09192,46.13,1.3198533908941568,14.239972547897718,3.515533729090286e-12,0.16473244589039757,235.05955881257475,0.9557124333421947,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-430144BB,Mission Solar Energy LLC,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.00747466,-0.13934249999999998,43.2,1.9206247755298367,11.090446120627426,7.106412910243101e-11,0.27252668724174006,6774.6762115524325,11.72253832985782,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-430144BW,Mission Solar Energy LLC,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.00747466,-0.13934249999999998,43.2,1.9206247755298367,11.090446120627426,7.106412910243101e-11,0.27252668724174006,6774.6762115524325,11.72253832985782,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-430144BB,Mission Solar Energy LLC,Mono-c-Si,0,430.0,400.4,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00669162,-0.12964050000000002,46.8,1.7912674015090457,11.190019968805931,1.115573224285382e-11,0.3177194711483144,178042.36079970284,3.397934512687735,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-430144BW,Mission Solar Energy LLC,Mono-c-Si,0,430.0,401.5,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00491241,-0.1282545,45.7,1.7822749127684092,11.197622941581903,9.619271457369746e-12,0.3198069719849507,469.4565749366308,3.5168948825623616,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE435SX9Z,Mission Solar Energy LLC,Mono-c-Si,0,435.0,405.9,2.14,,,72.0,11.31,49.42,10.78,40.34,0.0049764,-0.12700940000000002,44.75,1.8128967198839763,11.310003705113868,1.6386604251775298e-11,0.3275863323395404,999999.782491943,8.859809513750239,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSX10-435HN0B {A},Mission Solar Energy LLC,Mono-c-Si,0,435.0,405.6,1.94,,,54.0,13.76,38.7,13.02,33.4,0.0085312,-0.102942,46.5,1.4721392263912283,13.763350867041611,5.198860071982091e-11,0.05020941945496363,206.17996908298474,13.45965531300874,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-435HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,435.0,410.1,1.94,,,54.0,14.31,38.4,13.6,32.0,0.0061676100000000005,-0.09215999999999999,46.13,1.3225803338923545,14.318091685980463,3.486985430714778e-12,0.16287953075366304,288.0494986928657,0.8331089005871618,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-435120BB,Mission Solar Energy LLC,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,40.95,12.96,33.63,0.007395470000000001,-0.11138400000000001,43.6,1.5290244116054013,13.676148139014527,3.1761523952668715e-11,0.20361617907753368,452.7278143631316,6.721421091413095,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-435144BB,Mission Solar Energy LLC,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.00752184,-0.1399055,43.2,1.929833287779945,11.16102799124803,7.28496486134871e-11,0.26802474555028777,2909.710412982423,11.893019428052531,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-435144BW,Mission Solar Energy LLC,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.00752184,-0.1399055,43.2,1.929833287779945,11.16102799124803,7.28496486134871e-11,0.26802474555028777,2909.710412982423,11.893019428052531,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-435144BB,Mission Solar Energy LLC,Mono-c-Si,0,435.0,405.2,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00673348,-0.13016430000000004,46.8,1.8095453295740247,11.26675794721296,1.318224748292521e-11,0.3111958036334772,518.5102338106456,4.791081117467032,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-435144BW,Mission Solar Energy LLC,Mono-c-Si,0,435.0,406.3,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00494314,-0.12877270000000002,45.7,1.789972206459299,11.267298430122242,9.75734480831969e-12,0.3152333088639414,486.3411758535138,3.5834125788860685,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE440HT2B,Mission Solar Energy LLC,Mono-c-Si,0,440.0,412.1,2.1,,,60.0,13.69,41.01,12.98,33.91,0.0052022,-0.10252499999999999,45.52,1.4604580353201468,13.698773362248547,8.656082962233956e-12,0.19606488311717868,305.94066316344293,4.7364377131589395,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-440HN0B {A},Mission Solar Energy LLC,Mono-c-Si,0,440.0,401.9,1.94,,,54.0,13.91,39.6,13.19,33.4,0.008346,-0.11088000000000002,48.5,1.5867420172513602,13.913001306130562,2.0054069719717408e-10,0.10215819063795353,473.4673865877187,20.048019306109136,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-440HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,440.0,415.0,1.94,,,54.0,14.39,38.6,13.68,32.2,0.0062020899999999995,-0.09264,46.13,1.3299432159380458,14.397769819814526,3.5438490703174266e-12,0.16005446994028721,296.4269291034879,0.9205999997824331,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-440120BB,Mission Solar Energy LLC,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.02,13.05,33.72,0.007427930000000001,-0.11157440000000003,43.6,1.5305495397668754,13.733250837708983,3.138945279212656e-11,0.20025165287596605,845.7682522336652,6.571426706940132,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-440144BB,Mission Solar Energy LLC,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.007569020000000001,-0.1404685,43.2,1.866710648235963,11.230112914142936,2.7603601167722432e-11,0.2780775949614765,27656.541633959812,3.369717118948399,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-440144BW,Mission Solar Energy LLC,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.007569020000000001,-0.1404685,43.2,1.866710648235963,11.230112914142936,2.7603601167722432e-11,0.2780775949614765,27656.541633959812,3.369717118948399,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-440144BB,Mission Solar Energy LLC,Mono-c-Si,0,440.0,410.0,2.15,,,72.0,11.33,49.9,10.74,41.0,0.0067753399999999995,-0.1306881,46.8,1.8173355126096282,11.336446844873537,1.3370664650131784e-11,0.30668708878346684,538.9868728218673,4.85837221418425,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-440144BW,Mission Solar Energy LLC,Mono-c-Si,0,440.0,411.1,2.15,,,72.0,11.33,49.9,10.74,41.0,0.00497387,-0.1292909,45.7,1.7976698099741357,11.336980980561282,9.89637143342542e-12,0.31071959460617027,504.29205558800237,3.649427556698969,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE445HT2B,Mission Solar Energy LLC,Mono-c-Si,0,445.0,416.9,2.1,,,60.0,13.75,41.15,13.07,34.06,0.0052250000000000005,-0.102875,45.52,1.4644645797098732,13.755973491907866,8.556819421659214e-12,0.19292361778799494,444.07857329515116,4.589273746859357,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-445HN0B {A},Mission Solar Energy LLC,Mono-c-Si,0,445.0,406.6,1.94,,,54.0,14.02,39.7,13.31,33.4,0.008412,-0.11116000000000002,48.5,1.5876871480874124,14.022339887784238,1.9294531649182306e-10,0.10911509428524611,653.7893978535127,19.591914878159578,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-445HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,445.0,419.8,1.94,,,54.0,14.47,38.7,13.78,32.3,0.006236570000000001,-0.09288,46.13,1.3326805983915049,14.475957450041085,3.51596795916234e-12,0.15825686146251103,384.3887528627329,0.8007941597211241,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-445120BB,Mission Solar Energy LLC,Mono-c-Si,0,445.0,417.2,2.16,,,60.0,13.79,41.1,13.16,33.82,0.00746039,-0.11179200000000002,43.6,1.5230357694994607,13.790005128939356,2.629508271735187e-11,0.19826140688761676,533072.2356760007,5.002385774862916,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-445144BW,Mission Solar Energy LLC,Mono-c-Si,0,445.0,415.9,2.18,,,72.0,11.29,50.1,10.75,41.4,0.00760946,-0.14103149999999998,43.2,1.9457737635764378,11.291804332043654,7.421618610378759e-11,0.25959776787723093,999999.9472949086,11.950145616635265,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC TXS6-445144BB,Mission Solar Energy LLC,Mono-c-Si,0,445.0,414.8,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0068172,-0.13121190000000002,46.8,1.8251259568583593,11.406142688971055,1.3560366447230991e-11,0.30223709535016086,560.9111817088215,4.925155004544134,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-445144BW,Mission Solar Energy LLC,Mono-c-Si,0,445.0,415.9,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0050046000000000005,-0.1298091,45.7,1.7951160234162518,11.400007192237391,8.632779720938824e-12,0.30815851925527477,488447.83020992915,2.419494898633385,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE450HT2B,Mission Solar Energy LLC,Mono-c-Si,0,450.0,421.7,2.1,,,60.0,13.82,41.29,13.16,34.21,0.0052516,-0.103225,45.52,1.4689649520260895,13.824053642282433,8.538409195023125e-12,0.18966942212687177,646.6361020556798,4.519720243562379,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-450HN0B {A},Mission Solar Energy LLC,Mono-c-Si,0,450.0,411.4,1.94,,,54.0,14.14,39.8,13.44,33.5,0.008484,-0.11144,48.5,1.5911198941872977,14.14156970283489,1.9313587696212765e-10,0.10724791661572881,966.0974067048076,19.513932912611534,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-450HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,450.0,424.6,1.94,,,54.0,14.55,38.9,13.85,32.5,0.006271050000000001,-0.09336,46.13,1.3404715513638008,14.556427070584999,3.603096754521492e-12,0.15547569651424675,351.9755043504127,0.9613857800426787,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-450120BB,Mission Solar Energy LLC,Mono-c-Si,0,450.0,422.0,2.16,,,60.0,13.85,41.18,13.27,33.91,0.0074928500000000006,-0.11200960000000001,43.6,1.5301606964755194,13.850005010708049,2.842005641451503e-11,0.1947939459496308,538440.8843964805,5.629540063448199,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI6-450144BW,Mission Solar Energy LLC,Mono-c-Si,0,450.0,420.7,2.18,,,72.0,11.36,50.3,10.82,41.6,0.007656639999999999,-0.14159449999999998,43.2,1.9542971750206481,11.36449522382689,7.544150416986332e-11,0.255261749955157,999999.9476024729,12.04060921559822,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC TXS6-450144BB,Mission Solar Energy LLC,Mono-c-Si,0,450.0,419.6,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00685308,-0.1317357,46.8,1.8329579778918992,11.465886206252307,1.3747099710482085e-11,0.2981033228364801,580.3847124127503,4.9964478034051245,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXS6-450144BW,Mission Solar Energy LLC,Mono-c-Si,0,450.0,420.7,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00503094,-0.1303273,45.7,1.8031391296985968,11.46001282194526,8.794033877456291e-12,0.30396324043616585,271677.3853751143,2.5303995683389298,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE455HT2B,Mission Solar Energy LLC,Mono-c-Si,0,455.0,426.5,2.1,,,60.0,13.89,41.47,13.23,34.38,0.005278199999999999,-0.103675,45.52,1.475631587206361,13.893813117324209,8.626769621656735e-12,0.18773950251543,683.8766026893007,4.563566546410126,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-455HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,455.0,429.5,1.94,,,54.0,14.63,39.1,13.92,32.69,0.00630553,-0.09384,46.13,1.3480704021974488,14.636890762497515,3.6763405538766486e-12,0.15353847828616904,325.98249382711055,1.0859165770181345,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC TXI10-455120BB,Mission Solar Energy LLC,Mono-c-Si,0,455.0,426.8,2.16,,,60.0,13.93,41.33,13.36,34.06,0.007536130000000001,-0.1124176,43.6,1.5413926366914639,14.013466063613366,3.1741411496157716e-11,0.19047938999153652,999999.8801695533,6.4836709139633335,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSE460HT2B,Mission Solar Energy LLC,Mono-c-Si,0,460.0,431.3,2.1,,,60.0,13.97,41.64,13.31,34.55,0.005308600000000001,-0.1041,45.52,1.4820898338937343,13.97354791046993,8.746239076771936e-12,0.18494132294412766,728.2118117925996,4.631014823969918,-0.326,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSX10-460HN0B {B},Mission Solar Energy LLC,Mono-c-Si,0,460.0,434.3,1.94,,,54.0,14.71,39.3,13.99,32.89,0.00634001,-0.09431999999999999,46.13,1.355863324990596,14.717323378763417,3.7658349872297805e-12,0.1508084900705362,302.91931806259157,1.2437720633579568,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-530HT4T,Mission Solar Energy LLC,Mono-c-Si,1,530.0,488.8,2.588905,,,144.0,13.76,49.2,12.83,41.35,0.0046784,-0.12546000000000002,46.0,1.9050985191077214,13.776484742029949,8.145182183739543e-11,0.15207990615495467,126.94281335410204,23.180804478006618,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-530HT4T,Mission Solar Energy LLC,Mono-c-Si,0,530.0,499.1,2.58,,,72.0,13.71,49.2,12.82,41.4,0.005484,-0.140712,43.1,1.8177168054163746,13.726885700899235,2.347840466886919e-11,0.16348162284110615,132.73556544102203,-0.7620307730197329,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSN10-530HT4G,Mission Solar Energy LLC,Mono-c-Si,1,530.0,500.1,2.56,,,72.0,13.65,49.4,12.91,41.1,0.007917,-0.125476,43.1,1.8064673015290091,13.659625899526736,1.7937787312257725e-11,0.2075319981302047,294.2906049593908,9.14100600677269,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-530HT4T,Mission Solar Energy LLC,Mono-c-Si,0,530.0,496.9,2.56,,,72.0,13.65,49.4,12.91,41.1,0.004641000000000001,-0.141778,43.9,1.8132504249891308,13.659426359998525,1.9873399314937986e-11,0.20636530827523825,298.8307765702117,-2.3716730861796713,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-535HT4T,Mission Solar Energy LLC,Mono-c-Si,1,535.0,493.5,2.588905,,,144.0,13.83,49.35,12.9,41.5,0.0047022,-0.12584250000000002,46.0,1.9111230363845504,13.846107391907937,8.213694916212062e-11,0.14968494553122652,128.5212919116009,23.211979124317455,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSI10-535HT4G,Mission Solar Energy LLC,Mono-c-Si,0,535.0,504.0,2.57,,,72.0,13.78,49.35,12.9,41.5,0.0049608,-0.13669950000000003,43.2,1.806271561335822,13.796863230625167,1.8313478567849054e-11,0.1683047285652438,137.532316277253,0.44749532810311604,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-535HT4T,Mission Solar Energy LLC,Mono-c-Si,0,535.0,503.9,2.58,,,72.0,13.78,49.4,12.9,41.5,0.005512,-0.141284,43.1,1.822514816026605,13.796665255905195,2.2741037749837433e-11,0.1695403063963445,140.1877921182044,-1.0642107024438168,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSN10-535HT4G,Mission Solar Energy LLC,Mono-c-Si,1,535.0,505.0,2.56,,,72.0,13.71,49.6,12.96,41.3,0.0079518,-0.125984,43.1,1.8149588345979335,13.720078418356792,1.8326615163524308e-11,0.20445244729265222,278.1233098821654,9.29540374097511,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-535HT4T,Mission Solar Energy LLC,Mono-c-Si,0,535.0,501.7,2.56,,,72.0,13.71,49.6,12.96,41.3,0.0046614000000000004,-0.142352,43.9,1.8218066364316183,13.719876373870562,2.031279534202901e-11,0.2032783426783473,282.1831307321907,-2.230913991397626,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-540HT4T,Mission Solar Energy LLC,Mono-c-Si,1,540.0,498.3,2.588905,,,144.0,13.9,49.5,12.97,41.65,0.004726000000000001,-0.126225,46.0,1.9171485937296937,13.91573610184514,8.28250146265986e-11,0.1473156860033431,130.12676685626934,23.243091009726793,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSI10-540HT4G,Mission Solar Energy LLC,Mono-c-Si,0,540.0,508.8,2.57,,,72.0,13.85,49.5,12.97,41.65,0.004986,-0.13711500000000001,43.2,1.8119808541643319,13.866497868020243,1.8473938611055525e-11,0.16589436667043403,139.2687216411517,0.4760501974369761,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSI10-540HT4T,Mission Solar Energy LLC,Mono-c-Si,0,540.0,508.8,2.58,,,72.0,13.85,49.5,12.97,41.7,0.005540000000000001,-0.14156999999999997,43.1,1.8285216186657303,13.865594529876685,2.3658970186262416e-11,0.15879487076002038,141.0307965004113,-0.7876494396720093,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-540HT4G,Mission Solar Energy LLC,Mono-c-Si,1,540.0,509.8,2.56,,,72.0,13.77,49.8,13.02,41.5,0.0079866,-0.126492,43.1,1.8227910326273244,13.77979339344974,1.8553218302240063e-11,0.20145157166641417,283.25096620597145,9.36518533008313,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-540HT4T,Mission Solar Energy LLC,Mono-c-Si,0,540.0,506.5,2.56,,,72.0,13.77,49.8,13.02,41.5,0.0046818,-0.142926,43.9,1.8296808599384067,13.779593504455471,2.0567181343569753e-11,0.2002750807146412,287.464074903483,-2.1676839770429863,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-545HT4T,Mission Solar Energy LLC,Mono-c-Si,1,545.0,503.0,2.588905,,,144.0,13.95,49.65,13.05,41.8,0.004743,-0.1266075,46.0,1.9210106067427852,13.963878001254551,8.121648107052862e-11,0.14553214501071662,146.2871639781738,23.000679028855753,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSI10-545HT4G,Mission Solar Energy LLC,Mono-c-Si,0,545.0,513.7,2.57,,,72.0,13.92,49.65,13.04,41.8,0.0050111999999999995,-0.1375305,43.2,1.8176915013557222,13.936138154077105,1.8635249775520175e-11,0.1635096872618507,141.0356378193567,0.5045847959854592,-0.335,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSI10-545HT4T,Mission Solar Energy LLC,Mono-c-Si,0,545.0,513.6,2.58,,,72.0,13.92,49.7,13.04,41.8,0.005568,-0.142142,43.1,1.8340400207104455,13.935940720497232,2.314408745731457e-11,0.16471144347818584,143.83184898116463,-1.0067463365185205,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-545HT4G,Mission Solar Energy LLC,Mono-c-Si,1,545.0,514.6,2.56,,,72.0,13.83,51.8,13.08,41.7,0.008021400000000001,-0.131572,43.1,1.8634700151059087,13.841353982820856,1.1610798534558284e-11,0.3375711529180416,411.18690887254667,5.208083715377042,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-545HT4T,Mission Solar Energy LLC,Mono-c-Si,0,545.0,511.3,2.56,,,72.0,13.83,50.0,13.07,41.7,0.0047022,-0.1435,43.9,1.8382387937693856,13.840020241967292,2.1015863693467502e-11,0.1972372677904964,272.22810147586324,-2.028666554431003,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-550HT4T,Mission Solar Energy LLC,Mono-c-Si,1,550.0,507.8,2.588905,,,144.0,14.0,49.8,13.12,41.95,0.004760000000000001,-0.12699,46.0,1.9256406263956032,14.012571738585487,8.039763318415257e-11,0.14364320747047823,159.96235642096485,22.856407876915082,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSI10-550HT4G,Mission Solar Energy LLC,Mono-c-Si,0,550.0,518.5,2.57,,,72.0,13.99,49.8,13.11,41.95,0.0050364,-0.137946,43.2,1.8234027276358593,14.005784040827802,1.879719806351868e-11,0.16115040433542438,142.83377671204005,0.5330180589601994,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSI10-550HT4T,Mission Solar Energy LLC,Mono-c-Si,0,550.0,518.4,2.58,,,72.0,13.99,49.8,13.11,42.0,0.005596,-0.142428,43.1,1.8400454932892913,14.004900476948619,2.4070751679311814e-11,0.15410834765845804,144.69173037021588,-0.7321354881926299,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-550HT4G,Mission Solar Energy LLC,Mono-c-Si,1,550.0,519.5,2.56,,,72.0,13.89,50.2,13.13,41.9,0.0080562,-0.127508,43.1,1.8391146515679708,13.899937449338479,1.9179778433605873e-11,0.19547387224243926,273.22223209227576,9.585783119029951,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-550HT4T,Mission Solar Energy LLC,Mono-c-Si,0,550.0,516.1,2.56,,,72.0,13.89,50.2,13.13,41.9,0.0047226,-0.14407399999999998,43.9,1.8461121612297826,13.899737183420282,2.127416830305681e-11,0.19428756224852733,277.1493722715461,-1.9668413935634532,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-555HT4T,Mission Solar Energy LLC,Mono-c-Si,1,555.0,512.6,2.588905,,,144.0,14.07,49.95,13.2,42.1,0.004783800000000001,-0.12737250000000003,46.0,1.9309318843788013,14.081753631210727,8.03501050856801e-11,0.14146436405662502,169.3437196183177,22.796024406642736,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-555HT4G,Mission Solar Energy LLC,Mono-c-Si,0,555.0,523.3,2.57,,,72.0,14.02,49.95,13.18,42.09,0.005047199999999999,-0.13836150000000003,43.2,1.8263120107258464,14.03333693063161,1.8191119271098345e-11,0.16049584452420312,168.715862167801,0.23546213321016318,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-555HT4T,Mission Solar Energy LLC,Mono-c-Si,0,555.0,523.3,2.58,,,72.0,14.02,50.0,13.18,42.1,0.005608,-0.143,43.1,1.842935298986658,14.033061991031586,2.266780253735756e-11,0.16080489272716508,172.598848032139,-1.2445382027776486,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSH10-560HN4G,Mission Solar Energy LLC,Mono-c-Si,1,560.0,526.7,2.58,,,72.0,14.07,50.5,13.25,42.3,0.006092310000000001,-0.118877,46.25,1.762707093354844,14.085887085808086,4.984348355345822e-12,0.19688098557742,174.36271849145876,6.080153676453512,-0.299,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSI10-560HN4G,Mission Solar Energy LLC,Mono-c-Si,0,560.0,531.1,2.58,,,72.0,14.18,50.4,13.39,41.8,0.005856340000000001,-0.12085920000000001,43.5,1.745520893717618,14.195298350484297,4.028179846540787e-12,0.2310874197917206,214.1943097334639,2.257308418251746,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-560HN4G,Mission Solar Energy LLC,Mono-c-Si,0,560.0,532.1,2.56,,,72.0,14.11,50.7,13.34,42.0,0.0052207,-0.121173,43.0,1.7419287565762192,14.124450383644815,3.1829718962978833e-12,0.23985277441742459,234.20296175659647,0.7252866866922225,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-565HN4G,Mission Solar Energy LLC,Mono-c-Si,1,565.0,531.5,2.58,,,72.0,14.15,50.7,13.31,42.5,0.006126950000000001,-0.1193478,46.25,1.771265150687067,14.166854038604724,5.134920690986906e-12,0.19369119179464547,162.61564074893795,6.296377805725485,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-565HN4G,Mission Solar Energy LLC,Mono-c-Si,0,565.0,535.9,2.58,,,72.0,14.23,50.6,13.48,41.9,0.005876990000000001,-0.12133880000000001,43.5,1.7486608099731173,14.241888712814957,3.812043101776338e-12,0.2368080329386345,283.44349613720635,1.7484616404893434,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-565HN4G,Mission Solar Energy LLC,Mono-c-Si,0,565.0,537.0,2.56,,,72.0,14.17,50.9,13.39,42.2,0.005242899999999999,-0.121651,43.0,1.7498597751993374,14.184974777543703,3.25118571255126e-12,0.23685775858866273,224.12850135562718,0.8692007798019963,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-570HN4G,Mission Solar Energy LLC,Mono-c-Si,1,570.0,536.3,2.58,,,72.0,14.23,50.9,13.37,42.7,0.00616159,-0.1198186,46.25,1.779826605583655,14.247785176819123,5.2889370240066585e-12,0.19052892792665602,152.44305279126286,6.511352081509764,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-570HN4G,Mission Solar Energy LLC,Mono-c-Si,0,570.0,540.8,2.58,,,72.0,14.31,50.7,13.55,42.1,0.005910030000000001,-0.12157860000000001,43.5,1.7547578661982175,14.322153198945616,4.0010912003223425e-12,0.22609599010521875,266.22074119980755,2.1114816773770975,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-570HN4G,Mission Solar Energy LLC,Mono-c-Si,0,570.0,541.8,2.56,,,72.0,14.23,51.1,13.45,42.4,0.0052651,-0.122129,43.0,1.7572094722485994,14.24463527939972,3.291368316911901e-12,0.2338963813340526,227.41933549680093,0.9355846311541071,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-575HN4G,Mission Solar Energy LLC,Mono-c-Si,1,575.0,541.1,2.58,,,72.0,14.31,51.1,13.41,42.9,0.00619623,-0.1202894,46.25,1.7896262214002283,14.330016937450166,5.545204185024263e-12,0.18727802017879697,133.88404088298068,6.889866705808168,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-575HN4G,Mission Solar Energy LLC,Mono-c-Si,0,575.0,545.6,2.58,,,72.0,14.39,50.9,13.62,42.2,0.005943070000000001,-0.1220582,43.5,1.7607101390133517,14.4028851266668,3.958560492356172e-12,0.2312419322453214,258.2490263830511,1.9758679692187238,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-575HN4G,Mission Solar Energy LLC,Mono-c-Si,0,575.0,546.7,2.56,,,72.0,14.29,51.3,13.5,42.6,0.0052873,-0.122607,43.0,1.7651418169430533,14.305136527471795,3.3609866441666883e-12,0.23094784399360496,218.03182402826286,1.0777034563617454,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSH10-580HN4G,Mission Solar Energy LLC,Mono-c-Si,1,580.0,546.0,2.58,,,72.0,14.39,51.3,13.47,43.1,0.0062308699999999995,-0.1207602,46.25,1.7981993230783633,14.410854976477653,5.709034451888615e-12,0.18416387497667286,127.07365870124151,7.102415599201297,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-580HN4G,Mission Solar Energy LLC,Mono-c-Si,0,580.0,550.5,2.58,,,72.0,14.47,51.0,13.69,42.4,0.0059761100000000015,-0.122298,43.5,1.7668074643092455,14.483082512653223,4.153061390144952e-12,0.22066878335389692,244.07217375387637,2.3363638410440366,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-580HN4G,Mission Solar Energy LLC,Mono-c-Si,0,580.0,551.6,2.56,,,72.0,14.35,51.5,13.56,42.8,0.005309499999999999,-0.123085,43.0,1.772490639671126,14.364796888152387,3.401773626139784e-12,0.22803739131153503,221.1503206942208,1.1426817622303624,-0.297,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-585HN4G,Mission Solar Energy LLC,Mono-c-Si,1,585.0,550.8,2.58,,,72.0,14.47,51.5,13.53,43.3,0.006265510000000001,-0.121231,46.25,1.8067756760203795,14.491658334372218,5.876513143960484e-12,0.18107629849656545,120.97763356753049,7.313751711039498,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-585HN4G,Mission Solar Energy LLC,Mono-c-Si,0,585.0,555.3,2.58,,,72.0,14.05,52.7,13.3,44.0,0.005760500000000001,-0.12648,43.5,1.82947967708393,14.061550175353132,4.281392872429228e-12,0.2187864541054839,266.1387893797139,2.760077749199958,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-585HN4G,Mission Solar Energy LLC,Mono-c-Si,0,585.0,545.5,2.56,,,72.0,14.41,51.7,13.61,43.0,0.0175802,-0.161821,43.1,2.1953020058291686,14.413845052635635,8.479883011447108e-10,0.15859664613065813,594.3686133225226,19.507281610479254,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSH10-590HN4G,Mission Solar Energy LLC,Mono-c-Si,1,590.0,555.6,2.58,,,72.0,14.55,51.7,13.59,43.5,0.006300150000000001,-0.1217018,46.25,1.8153551713593148,14.572427317416317,6.047684330204988e-12,0.17801496039756742,115.48941087766894,7.523874420338827,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-590HN4G,Mission Solar Energy LLC,Mono-c-Si,0,590.0,560.2,2.58,,,72.0,14.11,52.9,13.36,44.2,0.0057851000000000005,-0.12696,43.5,1.8368730197070977,14.121261825945702,4.331066174717273e-12,0.2158821242285251,270.4798309677449,2.820879514858448,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-590HN4G,Mission Solar Energy LLC,Mono-c-Si,0,590.0,550.3,2.56,,,72.0,14.47,51.9,13.66,43.2,0.017653400000000003,-0.162447,43.1,2.2052997352716828,14.474219330812051,8.647421881903993e-10,0.15558281293282594,533.5642600458232,19.660164419435162,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSH10-595HN4G,Mission Solar Energy LLC,Mono-c-Si,1,595.0,560.5,2.58,,,72.0,14.62,51.85,13.67,43.55,0.0063304599999999996,-0.12205490000000002,46.25,1.8181841364569615,14.642301072289426,5.857347532550576e-12,0.1841244253450782,120.70715999694816,7.193722313149874,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSI10-595HN4G,Mission Solar Energy LLC,Mono-c-Si,0,595.0,565.0,2.58,,,72.0,14.17,53.1,13.42,44.4,0.0058097,-0.12744,43.5,1.8442659391472744,14.180978490405586,4.380952015168139e-12,0.21300414551620556,274.9256623688282,2.8811666325442578,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-595HN4G,Mission Solar Energy LLC,Mono-c-Si,0,595.0,555.1,2.56,,,72.0,14.53,52.1,13.72,43.4,0.0177266,-0.163073,43.1,2.2144572101506044,14.534022374079875,8.746151699737362e-10,0.15271476218470068,551.6509111676769,19.73030931644296,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Mission Solar Energy LLC MSH10-600HN4G,Mission Solar Energy LLC,Mono-c-Si,1,600.0,565.3,2.58,,,72.0,14.7,52.0,13.73,43.7,0.006365099999999999,-0.122408,46.25,1.8248442313704931,14.723169055992193,6.0117896100286565e-12,0.1815700160385332,115.20017211455736,7.380306113893433,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN10-600HN4G,Mission Solar Energy LLC,Mono-c-Si,0,600.0,560.0,2.56,,,72.0,14.59,52.3,13.77,43.6,0.0177998,-0.163699,43.1,2.2244551065202782,14.594373802470576,8.916569786968766e-10,0.14974647027732058,499.51998221000554,19.88119114100316,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Mission Solar Energy LLC MSN12-635HP3T,Mission Solar Energy LLC,Mono-c-Si,0,635.0,602.4,3.08,,,66.0,18.11,44.6,17.12,37.1,0.009257832,-0.18499634,42.4,1.6257206227562357,18.123647538572943,2.1783122259364252e-11,0.14234399421390234,188.8875226260656,-33.78294241921053,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-640HP3T,Mission Solar Energy LLC,Mono-c-Si,0,640.0,607.3,3.08,,,66.0,18.17,44.8,17.17,37.3,0.009288504000000001,-0.18582591999999998,42.4,1.634163284048591,18.18404696848005,2.2270198206624052e-11,0.14023152419655702,181.39193612253257,-33.680198516318264,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-645HP3T,Mission Solar Energy LLC,Mono-c-Si,0,645.0,612.1,3.08,,,66.0,18.22,45.0,17.21,37.5,0.009314064,-0.1866555,42.4,1.642636224953949,18.234458540601455,2.2761593534655042e-11,0.13820502596777842,174.1597341579392,-33.57602533399702,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-650HP3T,Mission Solar Energy LLC,Mono-c-Si,0,650.0,616.9,3.08,,,66.0,18.27,45.2,17.25,37.7,0.009339624,-0.18748508,42.4,1.6511121849021815,18.28484933539695,2.3260209902013866e-11,0.13618737947675547,167.55924560401954,-33.47251158908133,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-655HP3T,Mission Solar Energy LLC,Mono-c-Si,0,655.0,621.8,3.08,,,66.0,18.32,45.4,17.29,37.9,0.009365184,-0.18831466,42.4,1.6595911488304007,18.33521969373589,2.3766095108503252e-11,0.1341785248183781,161.51117298242687,-33.36965202976097,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-660HP3T,Mission Solar Energy LLC,Mono-c-Si,0,660.0,626.6,3.08,,,66.0,18.37,45.6,17.33,38.1,0.009390744,-0.18914424,42.4,1.6680731066401049,18.38556994896262,2.4279298130312813e-11,0.13217840399471334,155.9489565258613,-33.267445087714854,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-665HP3T,Mission Solar Energy LLC,Mono-c-Si,0,665.0,631.5,3.08,,,66.0,18.42,45.8,17.37,38.3,0.009416304000000002,-0.18997382,42.4,1.6765580169277925,18.435900425685517,2.4799858867990502e-11,0.13018694923750143,150.81631399762014,-33.16586489634109,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-670HP3T,Mission Solar Energy LLC,Mono-c-Si,0,670.0,636.3,3.08,,,66.0,18.47,46.0,17.42,38.5,0.009441864,-0.1908034,42.4,1.684533692644732,18.485553287240542,2.5135371804946408e-11,0.12824700027325034,152.29720059904142,-33.107817915047555,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-675HP3T,Mission Solar Energy LLC,Mono-c-Si,0,675.0,641.2,3.08,,,66.0,18.52,46.2,17.45,38.7,0.009467424,-0.19163298,42.4,1.6935367038676339,18.536503311228056,2.5863260774659493e-11,0.12622982820441192,141.65499257209166,-32.96461698401235,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mission Solar Energy LLC MSN12-680HP3T,Mission Solar Energy LLC,Mono-c-Si,0,680.0,646.1,3.08,,,66.0,18.57,46.4,17.49,38.9,0.009492984,-0.19246255999999998,42.4,1.702030433863781,18.58677633379625,2.6406190421726894e-11,0.12426403931216203,137.54991099606156,-32.864926020969065,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mitrex M295-RF041F,Mitrex,Mono-c-Si,0,295.0,267.9,2.0,,,72.0,7.64,48.4,7.28,40.5,0.00218504,-0.1320352,48.8,1.8000175053023237,7.641059342426104,1.600921662798174e-11,0.3180390953054268,2293.704785405959,5.841680950454493,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M300-RF041F,Mitrex,Mono-c-Si,0,300.0,272.6,2.0,,,72.0,7.77,48.4,7.41,40.5,0.0022222199999999996,-0.1320352,48.8,1.7993023409078797,7.770680747907917,1.6124153225910895e-11,0.31285179395662316,3570.864499262928,5.7548866756511705,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M305-RF041F,Mitrex,Mono-c-Si,0,305.0,277.2,2.0,,,72.0,7.9,48.5,7.51,40.6,0.0022594,-0.13230799999999998,48.8,1.806158490858123,7.90223944469125,1.71137341238926e-11,0.30532752224340604,1077.0917838648847,6.137094498083756,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M310-RF041F,Mitrex,Mono-c-Si,0,310.0,281.9,2.0,,,72.0,8.03,48.5,7.64,40.6,0.00229658,-0.13230799999999998,48.8,1.805424793685922,8.031865264252882,1.7223512264842925e-11,0.30052277066911876,1293.7565487716092,6.048183877938512,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M315-RF041F,Mitrex,Mono-c-Si,0,315.0,286.6,2.0,,,72.0,8.16,48.6,7.74,40.7,0.0023337600000000003,-0.1325808,48.8,1.8121977864318743,8.163397365201892,1.8245775263117576e-11,0.29342455662960076,704.7650973914062,6.418990825411842,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M320-RF041F,Mitrex,Mono-c-Si,0,320.0,291.1,2.0,,,72.0,8.29,48.6,7.86,40.7,0.00261964,-0.1320462,49.0,1.8144265836881084,8.293633482261093,1.9148733625040146e-11,0.28822875849097745,657.6105974893851,7.094417663412123,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M325-RF041F,Mitrex,Mono-c-Si,0,325.0,295.8,2.0,,,72.0,8.42,48.7,7.98,40.8,0.00266072,-0.13231790000000002,49.0,1.8188900468971732,8.423878607886081,1.9649088625655196e-11,0.281953605484793,612.0880120088661,7.184937607448428,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M330-RF041F,Mitrex,Mono-c-Si,0,330.0,300.5,2.0,,,72.0,8.55,48.7,8.09,40.8,0.0027018000000000003,-0.13231790000000002,49.0,1.8203419650027202,8.554764266088208,2.0344140658713926e-11,0.27738967970603073,497.8063031066878,7.360684190435749,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M335-RF041F,Mitrex,Mono-c-Si,0,335.0,305.1,2.0,,,72.0,8.68,48.8,8.19,40.9,0.0027428800000000005,-0.1325896,49.0,1.8269690413078241,8.686232745944178,2.1474316120744715e-11,0.27103635569268547,377.45732134050337,7.711807638722709,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M340-RF041F,Mitrex,Mono-c-Si,0,340.0,310.9,2.0,,,72.0,8.81,48.8,8.31,40.9,0.0030130200000000004,-0.13254080000000001,48.2,1.8294178871572802,8.81645149646231,2.2582083854711253e-11,0.266404095393689,363.79468167559315,8.027149632384353,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M345-RF041F,Mitrex,Mono-c-Si,0,345.0,315.6,2.0,,,72.0,8.94,48.9,8.41,41.0,0.00305748,-0.1328124,48.2,1.8359836160209608,8.947882371074744,2.3796402651571708e-11,0.2603780482453227,295.3146644810182,8.368885317932007,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M350-RF041F,Mitrex,Mono-c-Si,0,350.0,320.3,2.0,,,72.0,9.07,48.9,8.54,41.0,0.00310194,-0.1328124,48.2,1.8351593527287802,9.077528490632814,2.38807071124102e-11,0.2568073366849356,309.39037799704533,8.269532530524456,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M355-RF041F,Mitrex,Mono-c-Si,0,355.0,325.0,2.0,,,72.0,9.2,49.0,8.64,41.1,0.0031464,-0.133084,48.2,1.8416605322975523,9.20893299078413,2.512793416633596e-11,0.25108282485645395,258.58775193879785,8.602299443813797,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M390-A1F,Mitrex,Mono-c-Si,0,390.0,359.4,2.0,,,72.0,9.77,48.2,9.31,41.9,0.00358559,-0.1285976,47.5,1.8245049172028216,9.77067191602386,3.2660328027728744e-11,0.055608899726754535,808.5816377403237,12.295759904624152,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M395-B1F,Mitrex,Mono-c-Si,0,395.0,364.3,2.0,,,72.0,9.81,48.3,9.38,42.1,0.0033746400000000004,-0.1279467,47.4,1.8226887305812163,9.810213643248666,3.034704292578363e-11,0.044130648510264846,2026.3765906967478,12.414410155414265,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M395-L3H,Mitrex,Mono-c-Si,1,395.0,371.7,1.93,,,54.0,13.69,36.78,13.04,30.3,0.0064343,-0.09378900000000001,43.6,1.3273868910488578,13.692608237272772,1.2635173940026697e-11,0.18191486034440194,954.8266680474202,5.737284210443168,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M400-A1F,Mitrex,Mono-c-Si,0,400.0,368.9,2.0,,,72.0,9.87,48.3,9.46,42.3,0.0036222900000000002,-0.1288644,47.5,1.824491106090099,9.870000364256976,3.1417872801119686e-11,0.020697176977196616,560821.719409655,11.827920295101325,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M400-B1F,Mitrex,Mono-c-Si,0,400.0,369.0,2.0,,,72.0,9.87,48.3,9.46,42.3,0.0033952799999999997,-0.1279467,47.4,1.8248051901177877,9.87000020592666,3.1561474717311676e-11,0.020621412350779172,988395.6764796161,12.704942570836394,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M400-I3H,Mitrex,Mono-c-Si,0,400.0,372.1,1.95,,,54.0,13.65,36.74,12.83,31.23,0.008736,-0.10397419999999999,46.3,1.4036402974871698,13.658905409365639,5.741792822109932e-11,0.0875014782093398,134.12018739005885,7.510252503289689,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M400-L3H,Mitrex,Mono-c-Si,1,400.0,376.5,1.93,,,54.0,13.74,37.08,13.08,30.59,0.0064578,-0.09455399999999999,43.6,1.339491148343632,13.743358095132036,1.3010174317910424e-11,0.1789693953956059,732.2721502895592,5.9613139833370115,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M405-I3H,Mitrex,Mono-c-Si,0,405.0,376.9,1.95,,,54.0,13.7,36.94,12.86,31.49,0.008768,-0.10454019999999999,46.3,1.4143580455321836,13.708811565937703,6.08942489129035e-11,0.07941596716236633,123.47393960813181,7.997775857374858,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M405-L3H,Mitrex,Mono-c-Si,1,405.0,381.3,1.93,,,54.0,13.79,37.38,13.13,30.87,0.0064813,-0.095319,43.6,1.3509137882797184,13.793207629751555,1.3216534563964103e-11,0.176927734974341,760.6341210605252,6.065500099365578,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M410-I3H,Mitrex,Mono-c-Si,0,410.0,381.7,1.95,,,54.0,13.75,37.25,12.92,31.75,0.0088,-0.10541749999999998,46.3,1.425383595676322,13.75840889647707,6.025145218699851e-11,0.08032480409804417,131.3449476369168,7.8690107527837165,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M410-L3H,Mitrex,Mono-c-Si,1,410.0,386.1,1.93,,,54.0,13.83,37.68,13.18,31.17,0.0065001,-0.096084,43.6,1.362312163857925,13.832292739632639,1.3417487346418004e-11,0.17330485260001727,1045.389604988881,6.167571397989583,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M415-I3H,Mitrex,Mono-c-Si,0,415.0,386.5,1.95,,,54.0,13.8,37.52,12.97,32.05,0.008832000000000001,-0.1061816,46.3,1.4371827978814677,13.807746323815286,6.211087627752847e-11,0.07445342755888998,132.638123398135,8.10294034356969,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M415-L3H,Mitrex,Mono-c-Si,1,415.0,391.0,1.93,,,54.0,13.87,37.98,13.22,31.43,0.006518899999999999,-0.09684899999999999,43.6,1.3733225074543407,13.87216398486748,1.3502537636343649e-11,0.17315870092648045,1109.8566396493475,6.196765966276984,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Mitrex M440-H1H,Mitrex,Mono-c-Si,1,440.0,409.8,2.15,,,72.0,11.15,49.53,10.59,41.55,0.0054300500000000005,-0.14779752000000002,44.1,1.9158473567531498,11.15255038437624,6.567576657009899e-11,0.1970338403690134,861.4103385207696,4.873773367180391,-0.3758,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mitsubishi Electric PV-EE120MF5F,Mitsubishi Electric,Multi-c-Si,0,120.0,108.7,1.0076300000000002,1.495,0.674,36.0,7.75,21.6,6.99,17.2,0.00495225,-0.07454160000000001,43.0,0.9416047267589969,7.788725590112613,7.998277687230012e-10,0.23896070373650438,47.82227162231152,14.105065732047184,-0.4741,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-EE125MF5F,Mitsubishi Electric,Multi-c-Si,0,125.0,112.4,1.0076300000000002,1.495,0.674,36.0,7.9,21.8,7.23,17.3,0.0033733,-0.0792866,43.0,0.9594410921512997,7.926432647497297,1.0336409226539014e-09,0.24168064341979187,72.23179421334166,10.520802003762729,-0.5098,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-EE130MF5F,Mitsubishi Electric,Multi-c-Si,0,130.0,117.0,1.0076300000000002,1.495,0.674,36.0,8.05,21.9,7.47,17.4,0.00343735,-0.07965030000000001,43.0,0.9571085541072898,8.06427794125388,9.126574871525436e-10,0.23524648212146904,132.63361305717422,9.198048912184298,-0.5098,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MF170UD4,Mitsubishi Electric,Multi-c-Si,0,170.0,151.6,1.3844299999999998,1.658,0.835,50.0,7.83,29.9,7.19,23.7,0.005731560000000001,-0.1019291,47.3,1.2576891810410382,7.856552710490663,3.583589064491281e-10,0.35459722357495155,104.56546667305082,7.9885756251537865,-0.4429,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD170MF5,Mitsubishi Electric,Multi-c-Si,0,170.0,150.9,1.382772,1.658,0.834,50.0,7.83,29.9,7.19,23.7,0.0033434100000000007,-0.1087463,45.0,1.3124832182818453,7.853500150333371,9.692023465982465e-10,0.33923920735036106,113.03092504281383,10.012997371575516,-0.5098,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MF175UD4,Mitsubishi Electric,Multi-c-Si,0,175.0,156.1,1.3844299999999998,1.658,0.835,50.0,7.93,30.2,7.32,23.9,0.00580476,-0.1029518,47.3,1.2655392210637741,7.9521958409790345,3.3399628932103744e-10,0.3597385008489919,128.52528069494042,7.246989346040917,-0.4429,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD175MF5,Mitsubishi Electric,Multi-c-Si,0,175.0,157.0,1.382772,1.658,0.834,50.0,7.93,30.2,7.32,23.9,0.0059792199999999995,-0.1034954,46.4,1.2643331520561543,7.952261958971352,3.264616335175546e-10,0.3600726302286752,128.2625810333055,6.455172335378249,-0.4396,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MF180UD4,Mitsubishi Electric,Multi-c-Si,0,180.0,160.7,1.3844299999999998,1.658,0.835,50.0,8.03,30.4,7.45,24.2,0.00587796,-0.10363359999999999,47.3,1.274919499069954,8.046846070456063,3.4643901401312e-10,0.3348759454995412,159.6250146245202,7.4428095151811675,-0.4429,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD180MF5,Mitsubishi Electric,Multi-c-Si,0,180.0,161.6,1.382772,1.658,0.834,50.0,8.03,30.4,7.45,24.2,0.006054619999999999,-0.1041808,46.4,1.2737100258039922,8.04690522275677,3.3866489534533223e-10,0.335206386090598,159.2234371203788,6.65081788205347,-0.4396,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD185HA6,Mitsubishi Electric,Multi-c-Si,0,185.0,169.6,1.382772,1.658,0.834,50.0,8.24,30.3,7.44,24.9,0.0102176,-0.102414,45.2,1.293393753162779,8.268101709393855,5.20129650197224e-10,0.20594030082154374,60.38594096675436,11.264442253753659,-0.381,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD185MF5,Mitsubishi Electric,Multi-c-Si,0,185.0,166.2,1.382772,1.658,0.834,50.0,8.13,30.6,7.58,24.4,0.006130020000000001,-0.10486619999999999,46.4,1.280007835873044,8.142443226074635,3.3170757525824913e-10,0.3268612944810671,213.56059934392135,6.350007468089275,-0.4396,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD190HA6,Mitsubishi Electric,Multi-c-Si,0,190.0,174.3,1.382772,1.658,0.834,50.0,8.36,30.5,7.56,25.1,0.0103664,-0.10309,45.2,1.3018828623397698,8.386946576432285,5.281514195009049e-10,0.19900573577217892,61.740237771525486,11.26895856986814,-0.381,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD190MF5,Mitsubishi Electric,Multi-c-Si,0,190.0,169.8,1.3844299999999998,1.658,0.835,50.0,8.23,30.8,7.71,24.7,0.0031438600000000005,-0.10031559999999999,47.4,1.2492452091761188,8.23973165987787,1.5932249466538595e-10,0.31412073258204787,265.64984337528637,5.841247179129178,-0.4427,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UD195HA6,Mitsubishi Electric,Multi-c-Si,0,195.0,179.0,1.382772,1.658,0.834,50.0,8.48,30.6,7.69,25.4,0.0105152,-0.103428,45.2,1.3107807768399986,8.50159371802175,5.83377186908601e-10,0.16381493333583774,64.3312410584183,12.045724782811089,-0.381,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ212G6,Mitsubishi Electric,Multi-c-Si,0,212.0,194.5,1.6480519999999999,1.658,0.994,60.0,8.13,36.1,7.31,29.0,0.010569000000000002,-0.10830000000000001,45.5,1.4935595701172057,8.174186086203505,2.4310329925014535e-10,0.36475109251286986,67.11222334894205,18.09875680687346,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ218G6,Mitsubishi Electric,Multi-c-Si,0,218.0,200.1,1.6480519999999999,1.658,0.994,60.0,8.25,36.3,7.44,29.3,0.010725,-0.1089,45.5,1.5035538677426876,8.289907014659153,2.5437947412248275e-10,0.33943817555337846,70.17225090230546,18.390817140196372,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ220GA6,Mitsubishi Electric,Multi-c-Si,0,220.0,198.6,1.6480519999999999,1.658,0.994,60.0,8.2,36.2,7.39,29.7,0.012299999999999998,-0.11584000000000001,47.0,1.599923103012418,8.227175854007163,1.1522410068445869e-09,0.23915530153531625,72.16235681132144,25.336669967009314,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ220GA6-D,Mitsubishi Electric,Multi-c-Si,0,220.0,198.6,1.6480519999999999,1.658,0.994,60.0,8.2,36.2,7.39,29.7,0.012299999999999998,-0.11584000000000001,47.0,1.599923103012418,8.227175854007163,1.1522410068445869e-09,0.23915530153531625,72.16235681132144,25.336669967009314,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ224G6,Mitsubishi Electric,Multi-c-Si,0,224.0,205.7,1.6480519999999999,1.658,0.994,60.0,8.37,36.6,7.56,29.6,0.010881,-0.10980000000000001,45.5,1.5164095555252672,8.408265402525986,2.602826273401931e-10,0.3284122515555793,71.83540383367831,18.47012668286526,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ225GA6,Mitsubishi Electric,Multi-c-Si,0,225.0,203.2,1.6480519999999999,1.658,0.994,60.0,8.3,36.4,7.5,30.0,0.012450000000000001,-0.11648,47.0,1.6105910021066467,8.323852728014948,1.1998926165587582e-09,0.21664152299307507,75.38445185400249,25.627166567115836,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ225GA6-D,Mitsubishi Electric,Multi-c-Si,0,225.0,203.2,1.6480519999999999,1.658,0.994,60.0,8.3,36.4,7.5,30.0,0.012450000000000001,-0.11648,47.0,1.6105910021066467,8.323852728014948,1.1998926165587582e-09,0.21664152299307507,75.38445185400249,25.627166567115836,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ230GA6,Mitsubishi Electric,Multi-c-Si,0,230.0,207.8,1.6480519999999999,1.658,0.994,60.0,8.39,36.6,7.62,30.2,0.012585,-0.11712000000000002,47.0,1.6159446830882667,8.411159195343803,1.1620523378973247e-09,0.21124323628763444,83.76173657823405,25.16871754719863,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ230GA6-D,Mitsubishi Electric,Multi-c-Si,0,230.0,207.8,1.6480519999999999,1.658,0.994,60.0,8.39,36.6,7.62,30.2,0.012585,-0.11712000000000002,47.0,1.6159446830882667,8.411159195343803,1.1620523378973247e-09,0.21124323628763444,83.76173657823405,25.16871754719863,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJU235GB,Mitsubishi Electric,Mono-c-Si,0,235.0,212.6,1.525776,1.596,0.956,60.0,8.49,36.8,7.95,29.6,0.0050940000000000004,-0.12512,45.0,1.5474854546959749,8.49852486219692,3.944229115050251e-10,0.3372622853433715,335.88314353581353,8.506216704018712,-0.456,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ235GA6,Mitsubishi Electric,Multi-c-Si,0,235.0,212.4,1.6480519999999999,1.658,0.994,60.0,8.49,36.8,7.71,30.5,0.012735,-0.11776,47.0,1.6289920761546801,8.509426782771802,1.2461267380231807e-09,0.18911602899819935,82.64854134541027,25.77411337566941,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-UJ235GA6-D,Mitsubishi Electric,Multi-c-Si,0,235.0,212.4,1.6480519999999999,1.658,0.994,60.0,8.49,36.8,7.71,30.5,0.012735,-0.11776,47.0,1.6289920761546801,8.509426782771802,1.2461267380231807e-09,0.18911602899819935,82.64854134541027,25.77411337566941,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJU240GB,Mitsubishi Electric,Mono-c-Si,0,240.0,217.2,1.525776,1.596,0.956,60.0,8.6,37.0,8.07,29.8,0.00516,-0.1258,45.0,1.555347665901607,8.606815307392772,3.971350778693971e-10,0.3291097111304603,415.2922539412816,8.44648822971524,-0.456,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJU245GB,Mitsubishi Electric,Mono-c-Si,0,245.0,221.9,1.525776,1.596,0.956,60.0,8.72,37.2,8.18,30.0,0.0052320000000000005,-0.12648000000000004,45.0,1.5651975022645483,8.727156792880363,4.11382395967946e-10,0.3206925401053591,390.7392312800764,8.635875303196507,-0.456,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLU250HC,Mitsubishi Electric,Mono-c-Si,0,250.0,225.8,1.528281,1.587,0.963,60.0,8.79,37.6,8.08,31.0,0.009141599999999998,-0.145512,45.7,1.6946760357364474,8.804820403709858,1.9641949870052254e-09,0.20169213425183444,119.62388653806036,7.75745981096865,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE255HD,Mitsubishi Electric,Mono-c-Si,0,255.0,230.5,1.528281,1.587,0.963,60.0,8.89,37.8,8.18,31.2,0.0092456,-0.146286,45.7,1.70388541032452,8.904164743386078,1.9937224243446165e-09,0.19561064552472635,122.76813110823893,7.787210052696587,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLU255HC,Mitsubishi Electric,Mono-c-Si,0,255.0,230.5,1.528281,1.587,0.963,60.0,8.89,37.8,8.18,31.2,0.0092456,-0.146286,45.7,1.70388541032452,8.904164743386078,1.9937224243446165e-09,0.19561064552472635,122.76813110823893,7.787210052696587,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE260HD,Mitsubishi Electric,Mono-c-Si,0,260.0,235.1,1.528281,1.587,0.963,60.0,8.98,38.0,8.29,31.4,0.0093392,-0.14706,45.7,1.7107382297854095,8.99240916113594,1.965758767573483e-09,0.1904846147934076,137.84592588815124,7.564276680300855,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLU260HC,Mitsubishi Electric,Mono-c-Si,0,260.0,235.1,1.528281,1.587,0.963,60.0,8.98,38.0,8.29,31.4,0.0093392,-0.14706,45.7,1.7107382297854095,8.99240916113594,1.965758767573483e-09,0.1904846147934076,137.84592588815124,7.564276680300855,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJE265FB,Mitsubishi Electric,Mono-c-Si,0,265.0,239.3,1.4339140000000001,1.574,0.911,60.0,9.1,38.0,8.59,30.9,0.005369,-0.13186,46.0,1.6157238095647268,9.102027805782951,5.540569328532572e-10,0.2757229102129244,1237.3379431936726,8.637817636585675,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE265HD,Mitsubishi Electric,Mono-c-Si,0,265.0,239.3,1.4601600000000001,1.56,0.936,60.0,9.08,38.2,8.38,31.7,0.007354800000000001,-0.14248600000000003,45.9,1.705443644539345,9.092082451634772,1.6475893375109983e-09,0.1748715976547321,131.41657732385994,10.211730928033807,-0.466,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE265HD2,Mitsubishi Electric,Mono-c-Si,0,265.0,238.1,1.4601600000000001,1.56,0.936,60.0,9.08,38.2,8.38,31.7,0.0046308,-0.12873400000000004,48.5,1.5982959470503297,9.095510340287028,3.6581882614817945e-10,0.20174065876353123,118.10219764394347,8.405101774348168,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJE270FB,Mitsubishi Electric,Mono-c-Si,0,270.0,244.0,1.4339140000000001,1.574,0.911,60.0,9.23,38.2,8.69,31.1,0.0054457,-0.132554,46.0,1.6276368736254612,9.234081247490474,5.88433277955019e-10,0.26793933430040406,605.9620051890159,9.053115195880293,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE270HD,Mitsubishi Electric,Mono-c-Si,0,270.0,242.3,1.4601600000000001,1.56,0.936,60.0,9.18,38.4,8.48,31.9,0.0041769,-0.164544,46.5,1.696779548092888,9.192039121840969,1.3210795336653166e-09,0.1737092160032255,132.45574692229363,-5.580373764107207,-0.4806,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE270HD2,Mitsubishi Electric,Mono-c-Si,0,270.0,242.8,1.4601600000000001,1.56,0.936,60.0,9.18,38.4,8.48,31.9,0.004681799999999999,-0.12940800000000002,48.5,1.6068388985642132,9.19488297287461,3.711737847078049e-10,0.1960563309553211,120.92995304235177,8.433550198856516,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJE275FB,Mitsubishi Electric,Mono-c-Si,0,275.0,247.6,1.6268999999999998,1.65,0.986,60.0,9.36,38.3,8.79,31.3,0.0055224,-0.132901,46.0,1.6377669312342638,9.36595584092101,6.468301909238692e-10,0.2486962993555221,390.84290108830527,9.77819396048712,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJE275FB-B,Mitsubishi Electric,Mono-c-Si,0,275.0,247.5,1.647058,1.657,0.994,60.0,9.36,38.3,8.79,31.3,0.0055224,-0.132901,46.0,1.6377669312342638,9.36595584092101,6.468301909238692e-10,0.2486962993555221,390.84290108830527,9.77819396048712,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE275HD2,Mitsubishi Electric,Mono-c-Si,0,275.0,247.4,1.4601600000000001,1.56,0.936,60.0,9.28,38.5,8.58,32.1,0.0047328,-0.129745,48.5,1.6136449204869712,9.293488348860468,3.9033848300847225e-10,0.17861580975934224,122.88789513886616,8.778214087564093,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJE280FB,Mitsubishi Electric,Mono-c-Si,0,280.0,252.2,1.647058,1.657,0.994,60.0,9.5,38.4,8.9,31.5,0.005605,-0.133248,46.0,1.647832691899443,9.507497724751214,7.103713946932283e-10,0.22965764901498617,290.98804144379244,10.492012030719373,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MJE280FB-B,Mitsubishi Electric,Mono-c-Si,0,280.0,252.2,1.647058,1.657,0.994,60.0,9.5,38.4,8.9,31.5,0.005605,-0.133248,46.0,1.647832691899443,9.507497724751214,7.103713946932283e-10,0.22965764901498617,290.98804144379244,10.492012030719373,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +Mitsubishi Electric PV-MLE280HD2,Mitsubishi Electric,Mono-c-Si,0,280.0,252.1,1.4601600000000001,1.56,0.936,60.0,9.37,38.6,8.68,32.4,0.0047786999999999994,-0.130082,48.5,1.622381970241986,9.380766114025489,4.2206020722668265e-10,0.14849367331287974,129.23751222545738,9.376911235349539,-0.433,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-345W-m60H,MSquare Energy Pty Ltd,Mono-c-Si,0,345.0,322.3,1.84,,,60.0,10.53,41.25,10.03,34.39,0.005991569999999999,-0.11389125000000001,43.8,1.5584147655749834,10.531092145026673,3.358793842727691e-11,0.20527383880763123,1979.16363619847,7.806695296151971,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-345W-m60HB,MSquare Energy Pty Ltd,Mono-c-Si,0,345.0,321.9,1.84,,,60.0,10.53,41.25,10.03,34.39,0.00616005,-0.12742125,43.9,1.5787918936919714,10.5307040045344,4.7296614069288905e-11,0.20082958348517294,3003.8668933084123,-1.0417211689411352,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-345W-m60HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,345.0,322.1,1.84,,,60.0,10.53,41.25,10.03,34.39,0.00462267,-0.1215225,43.8,1.5477539683900705,10.531301854060326,2.7980703164282417e-11,0.20760770336044077,1679.2275928616612,-0.3257612591984272,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-350W-m60H,MSquare Energy Pty Ltd,Mono-c-Si,0,350.0,327.1,1.84,,,60.0,10.59,41.4,10.06,34.79,0.006025709999999999,-0.1143054,43.8,1.5725263060899102,10.592840284630766,3.878612270652644e-11,0.17311799510851908,645.4703882944182,9.034184962399278,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-350W-m60HB,MSquare Energy Pty Ltd,Mono-c-Si,0,350.0,326.7,1.84,,,60.0,10.59,41.4,10.06,34.79,0.00619515,-0.1278846,43.9,1.5934157272289622,10.592460346352876,5.4808294232334006e-11,0.16854699245635907,725.4721393986703,0.11122169646889436,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-350W-m60HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,350.0,326.9,1.84,,,60.0,10.59,41.4,10.06,34.79,0.00464901,-0.12196439999999999,43.8,1.5618611089638457,10.593040929415057,3.239368264622656e-11,0.175460548462941,611.0392579757236,0.8281823936151946,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-355W-m60H,MSquare Energy Pty Ltd,Mono-c-Si,0,355.0,331.8,1.84,,,60.0,10.63,41.6,10.1,35.14,0.00604847,-0.11485760000000002,43.8,1.58418694323585,10.632606300786312,4.16421772783151e-11,0.1526063134462177,622.4167090353914,9.630494114976107,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-355W-m60HB,MSquare Energy Pty Ltd,Mono-c-Si,0,355.0,331.4,1.84,,,60.0,10.63,41.6,10.1,35.14,0.006218550000000001,-0.12850240000000002,43.9,1.6053928637719028,10.632260392593455,5.894559672488682e-11,0.1479676332310073,695.8508066451592,0.6719426572250132,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-355W-m60HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,355.0,331.7,1.84,,,60.0,10.63,41.6,10.1,35.14,0.00466657,-0.1225536,43.8,1.5734903881651112,10.632787401562478,3.482313243803032e-11,0.15495496786291527,590.9343551677294,1.3888968197357725,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-360W-m60H,MSquare Energy Pty Ltd,Mono-c-Si,0,360.0,336.6,1.84,,,60.0,11.24,41.8,10.23,35.19,0.00639556,-0.1154098,43.8,1.624810180241933,11.266136035228971,7.135961482391429e-11,0.15056060863872167,64.74973089779319,14.177283501976222,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-360W-m60HB,MSquare Energy Pty Ltd,Mono-c-Si,0,360.0,336.2,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0065754,-0.1291202,43.9,1.647799265926316,11.264976095563732,1.0223137341234119e-10,0.14555818422640596,65.50559505620262,4.937568070973225,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-360W-m60HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,360.0,336.5,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0049343600000000005,-0.12314279999999998,43.8,1.6143710749462203,11.26667103590045,6.040727023587574e-11,0.15284083591743033,64.41185897355605,5.694412837985603,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-365W-m60H,MSquare Energy Pty Ltd,Mono-c-Si,0,365.0,341.4,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0064297,-0.115962,43.8,1.6279961137227528,11.324537698439016,6.707982110566852e-11,0.15453245804335491,71.16465260224258,13.540874505351042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-365W-m60HB,MSquare Energy Pty Ltd,Mono-c-Si,0,365.0,341.0,1.84,,,60.0,11.3,42.0,10.33,35.33,0.006610500000000001,-0.129738,43.9,1.6508546900057997,11.323455053150314,9.593789047779915e-11,0.1496146493374621,72.08022675703677,4.3396540493048095,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-365W-m60HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,365.0,341.3,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0049607,-0.12373199999999998,43.8,1.6174541226173103,11.32504521912303,5.6682304177878583e-11,0.15680912308680353,70.74975428077438,5.090868735469773,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-370W-m60H,MSquare Energy Pty Ltd,Mono-c-Si,0,370.0,346.2,1.84,,,60.0,11.36,42.2,10.45,35.4,0.006463839999999999,-0.11651420000000001,43.8,1.6278813277492246,11.382761958473912,5.999208639221643e-11,0.16649289807193457,83.09299637870247,12.445711814615798,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-370W-m60HB,MSquare Energy Pty Ltd,Mono-c-Si,0,370.0,345.8,1.84,,,60.0,11.36,42.2,10.45,35.4,0.0066456,-0.13035580000000002,43.9,1.6504353567811691,11.381779156463201,8.554753600302316e-11,0.16171298513118007,84.34943423732544,3.31054810904644,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-370W-m60HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,370.0,346.0,1.84,,,60.0,11.36,42.2,10.45,35.4,0.00498704,-0.1243212,43.8,1.6172082503039238,11.383235182170656,5.0543836988284634e-11,0.16876347395881114,82.51078281019736,4.053954503994833,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-395W-M54H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,395.0,369.9,1.94,,,54.0,13.71,36.9,13.03,30.32,0.0075542100000000004,-0.112914,43.7,1.3901919454845586,13.712789311305112,4.057672810756181e-11,0.17929749260596675,881.2816158777111,-3.3641479466216184,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-400W-M54H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,400.0,374.7,1.94,,,54.0,13.78,36.98,13.15,30.42,0.00759278,-0.11315879999999999,43.7,1.3932808888272739,13.780002369865963,4.095885374924027e-11,0.17196284524657945,999993.3728430948,-3.339551890136537,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-405W-M54H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,405.0,379.5,1.94,,,54.0,13.85,37.06,13.27,30.52,0.007631350000000001,-0.11340360000000001,43.7,1.3995425280786216,13.8500173506153,4.378122415100114e-11,0.15815225238486358,126245.06625006764,-2.85656199569528,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-410W-M54H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,410.0,384.3,1.94,,,54.0,13.92,37.14,13.39,30.62,0.00766992,-0.1136484,43.7,1.4057758384631394,13.920002399372127,4.674792568248753e-11,0.1438046043844299,834174.8946760175,-2.379681738122871,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-415W-M54H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,415.0,389.1,1.94,,,54.0,14.01,37.31,13.48,30.79,0.007719510000000001,-0.11416860000000001,43.7,1.4129881286490693,14.010002357434763,4.7739309343769745e-11,0.14042026074374248,834392.6504611396,-2.2647717912631227,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-415W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,415.0,387.7,2.21,,,72.0,11.23,49.6,10.08,41.15,0.006389870000000001,-0.13694560000000003,43.8,1.9271730242120406,11.275835023557631,6.944384325500057e-11,0.24537088518324618,60.11811118537737,13.981645867970887,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-415W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,415.0,387.3,2.21,,,72.0,11.23,49.6,10.08,41.15,0.0049299700000000005,-0.1461216,43.9,1.9147971237492492,11.276538175890673,5.87862246434601e-11,0.2480946212605528,59.86703508387783,5.515747616238673,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-415W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,415.0,387.5,2.21,,,72.0,11.23,49.6,10.08,41.15,0.0049299700000000005,-0.1461216,43.8,1.9147971237492492,11.276538175890673,5.87862246434601e-11,0.2480946212605528,59.86703508387783,5.515747616238673,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-420W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,420.0,392.5,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00641263,-0.1374978,43.8,1.924275612696981,11.31293592026113,6.09726878700558e-11,0.2600136617475694,68.24947421628364,12.727371690319782,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-420W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,420.0,392.0,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00659295,-0.1538322,43.9,1.951007151081974,11.311542692840815,8.697378039427566e-11,0.25423863398445407,68.97168260170793,3.5691810931519705,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-420W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,420.0,392.3,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00494753,-0.14671079999999997,43.8,1.9117347014768715,11.31359838481594,5.143806616521304e-11,0.262733302133244,67.91545931249719,4.327504679843871,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-425W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,425.0,397.2,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00642401,-0.13805,43.8,1.920119686782371,11.32762249190583,5.26150851471865e-11,0.27379873355090534,82.16329012473263,11.33962396657383,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-425W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,425.0,396.8,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00660465,-0.15445,43.9,1.946344078921541,11.326390454424786,7.477315224594048e-11,0.26821651782241673,83.21315458114935,2.2662306913522463,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-425W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,425.0,397.0,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00495631,-0.1473,43.8,1.9074184082751062,11.3282278351693,4.422606743127526e-11,0.2765126468710977,81.66373491573208,3.0145851067784473,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-430W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,430.0,402.0,2.21,,,72.0,11.3,50.2,10.36,41.51,0.0064297,-0.1386022,43.8,1.9249664106109183,11.332475061769282,5.0969066282848636e-11,0.2657101017137451,92.4563034329522,11.027510616055379,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-430W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,430.0,401.5,2.21,,,72.0,11.3,50.2,10.36,41.51,0.006610500000000001,-0.1550678,43.9,1.9511598594549733,11.331348435421756,7.237893153737509e-11,0.2601647733633265,93.78018146089012,1.9743736468362443,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-430W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,430.0,401.8,2.21,,,72.0,11.3,50.2,10.36,41.51,0.0049607,-0.1478892,43.8,1.9121862296374148,11.333033207741956,4.280383197557569e-11,0.2684260255751194,91.82317754589283,2.71827473914128,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-435W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,435.0,406.8,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00643539,-0.13901635,43.8,1.924568686057769,11.336738709564765,4.731420417143629e-11,0.26420393433870276,111.75358010691457,10.326639687995666,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-435W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,435.0,406.3,2.21,,,72.0,11.31,50.35,10.44,41.66,0.006616350000000001,-0.15553115000000003,43.9,1.9505326261159281,11.335741569257468,6.706531849378671e-11,0.2587554721796313,113.68865618248695,1.3174222295105524,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-435W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,435.0,406.6,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00496509,-0.1483311,43.8,1.9117002752017433,11.337241145805205,3.9662350734410156e-11,0.2669145689428395,110.81779668211968,2.0553314445877207,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-440W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-440W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-440W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,440.0,411.6,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00645246,-0.1394305,43.8,1.9124794349887924,11.363041723554051,3.738174534735004e-11,0.26483785869404597,130.34013402256596,8.20169258294452,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-440W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,440.0,411.1,2.21,,,72.0,11.34,50.5,10.52,41.81,0.006633900000000001,-0.1559945,43.9,1.9518542605852915,11.361652353741434,6.373939404646147e-11,0.2566328218030774,134.40646053918988,0.8629499066944296,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-440W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,440.0,411.4,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00497826,-0.148773,43.8,1.9130868303524184,11.363019910950262,3.7697003654815584e-11,0.26471080823934795,130.40105109924505,1.5968095271374523,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-445W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-445W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-445W-m72H,MSquare Energy Pty Ltd,Mono-c-Si,0,445.0,416.4,2.21,,,72.0,11.37,50.58,10.61,41.96,0.006469529999999999,-0.13965138000000002,43.8,1.9253852741335864,11.387332575414236,4.3222162224326944e-11,0.2532351485909144,166.11978286616585,9.432638289090042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-445W-m72HB,MSquare Energy Pty Ltd,Mono-c-Si,0,445.0,415.9,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00665145,-0.15624162000000003,43.9,1.9510767268211706,11.386540933617326,6.112345888567276e-11,0.24793320976451697,170.42572651439679,0.4803109068239914,-0.3593,N,2025.7.3,6/23/2025,4.0,bootstrapping +MSquare Energy Pty Ltd MSE-445W-m72HBi,MSquare Energy Pty Ltd,Mono-c-Si,1,445.0,416.2,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00499143,-0.14900868,43.8,1.9123979902602979,11.387740649298621,3.614853084898033e-11,0.2559254641843815,164.02288890230403,1.209671200758284,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-450W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MSE-450W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-455W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,455.0,426.6,2.14,,,60.0,13.93,41.33,13.36,34.06,0.0076754300000000004,-0.1264698,43.7,1.561482588686671,13.930004894121794,4.455061537197176e-11,0.18795642225008663,534996.2075622685,-2.764886288840815,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-460W-M60H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,460.0,431.4,2.14,,,60.0,14.01,41.48,13.45,34.2,0.007719510000000001,-0.1269288,43.7,1.5684678629551188,14.01028556728525,4.580062315481237e-11,0.1859467515856264,9122.598678731394,-2.5911118818842573,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-485W-M66H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,485.0,454.2,2.37,,,22.0,13.67,45.1,12.79,37.93,0.007532170000000001,-0.138006,43.7,1.7341163874434073,13.684142614798235,6.770436880762103e-11,0.1401695789773259,135.48542410342037,0.8117181728494309,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-490W-M66H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,490.0,459.0,2.37,,,22.0,13.74,45.25,12.87,38.08,0.00757074,-0.138465,43.7,1.739444881115227,13.753257793539937,6.769189443408024e-11,0.13793924834022903,142.95631378771046,0.7646297247871167,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-495W-M66H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,495.0,463.8,2.37,,,22.0,13.82,45.4,12.95,38.23,0.007614820000000001,-0.138924,43.7,1.7454394565528757,13.832891573193567,6.834582497943429e-11,0.13553094426823467,145.2916289099403,0.7943935219552436,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-500W-M66H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,500.0,468.6,2.37,,,22.0,13.93,45.45,13.06,38.29,0.0076754300000000004,-0.139077,43.7,1.7473174450278304,13.942505025116445,6.888450378834534e-11,0.13310264538939942,148.26998365133997,0.7919375358990965,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-505W-M66H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,505.0,473.5,2.37,,,22.0,14.01,45.6,13.14,38.43,0.007719510000000001,-0.139536,43.7,1.753070697036933,14.022223720769649,6.929505838267091e-11,0.13163668853458735,150.87304939715457,0.7923890704810548,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +MSquare Energy Pty Ltd MGS-530W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-530W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-535W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-535W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-540W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-540W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-545W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.52,13.36,40.8,0.00768094,-0.1515312,43.7,1.870684691617212,13.9400028925779,4.4442188120097235e-11,0.20748896460190644,999993.9298367809,-2.7897108880311374,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MSE-545W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.52,13.36,40.8,0.00768094,-0.1515312,43.7,1.870684691617212,13.9400028925779,4.4442188120097235e-11,0.20748896460190644,999993.9298367809,-2.7897108880311374,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +MSquare Energy Pty Ltd MGS-550W-M72H-M10,MSquare Energy Pty Ltd,Mono-c-Si,0,550.0,515.8,2.56,,,72.0,14.03,49.62,13.45,40.9,0.007730530000000001,-0.15183719999999998,43.7,1.875059829127246,14.030002864676204,4.510802130948321e-11,0.20416909236898073,999992.6444283266,-2.7233274202719366,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Mundra Solar Energy Limited (Adani) ASB-M10-144-530,Mundra Solar Energy Limited (Adani),Mono-c-Si,1,530.0,490.8,2.57,,,72.0,13.55,48.95,12.79,41.49,0.006937600000000001,-0.13975225,46.19,1.8877775596672726,13.556618764213964,7.323584423396986e-11,0.12466302999943987,255.2114003339383,8.887477403901453,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar Energy Limited (Adani) ASB-M10-144-535,Mundra Solar Energy Limited (Adani),Mono-c-Si,1,535.0,495.6,2.57,,,72.0,13.63,49.12,12.86,41.64,0.006978560000000001,-0.1402376,46.19,1.8948906600915054,13.636871839215386,7.419341193265293e-11,0.12375527126568034,245.46329908147126,8.951811203114703,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar Energy Limited (Adani) ASB-M10-144-540,Mundra Solar Energy Limited (Adani),Mono-c-Si,1,540.0,500.4,2.57,,,72.0,13.71,49.32,12.93,41.8,0.0070195200000000004,-0.1408086,46.19,1.90279114791475,13.717188346480514,7.478157288063652e-11,0.12430828853690619,237.0874395826335,8.971506569176213,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar Energy Limited (Adani) ASB-M10-144-545,Mundra Solar Energy Limited (Adani),Mono-c-Si,1,545.0,505.1,2.57,,,72.0,13.79,49.48,13.01,41.94,0.00706048,-0.14126539999999999,46.19,1.908726770792671,13.797015237716867,7.500617370243812e-11,0.1236613618893897,243.083737422234,8.945260583336164,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar Energy Limited (Adani) ASB-M10-144-550,Mundra Solar Energy Limited (Adani),Mono-c-Si,1,550.0,509.9,2.57,,,72.0,13.85,49.67,13.07,42.09,0.007091200000000001,-0.14180784999999999,46.19,1.9155373552268575,13.85694368370827,7.483017801621034e-11,0.1246190065279585,248.56737933570702,8.885233934041633,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-7-370,Mundra Solar PV Limited (Adani),Mono-c-Si,1,370.0,339.3,2.01,,,72.0,9.73,48.8,9.24,40.06,0.006052060000000001,-0.13732319999999998,47.39,1.878286992594604,9.731781908974966,5.0526957704005846e-11,0.32949444010193535,1799.1835483043672,9.948716868780085,-0.3732,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-7-375,Mundra Solar PV Limited (Adani),Mono-c-Si,1,377.1,346.0,2.01,,,72.0,9.76,48.75,9.33,40.42,0.00607072,-0.13718249999999999,47.39,1.8862663068416128,9.760002553055019,5.824171181819166e-11,0.2615663028894177,999999.8034993627,11.182927138043903,-0.3732,N,2025.7.3,6/23/2025,2.0,first_pass +Mundra Solar PV Limited (Adani) ASB-7-380,Mundra Solar PV Limited (Adani),Mono-c-Si,1,380.0,348.7,2.01,,,72.0,10.06,48.19,9.64,39.5,0.00625732,-0.13560666,47.39,1.8571969755211626,10.060002913764269,5.415652006653891e-11,0.289548838884167,999760.7153524341,10.26050311814882,-0.3732,N,2025.7.3,6/23/2025,2.0,first_pass +Mundra Solar PV Limited (Adani) ASB-7-385,Mundra Solar PV Limited (Adani),Mono-c-Si,1,385.0,353.5,2.01,,,72.0,10.11,48.9,9.74,39.66,0.006288419999999999,-0.1376046,47.39,1.8808999803176805,10.110264622138397,5.1726429766262895e-11,0.30821098521849016,11775.339751574938,9.808993521235402,-0.3732,N,2025.7.3,6/23/2025,2.0,first_pass +Mundra Solar PV Limited (Adani) ASB-M10-144-550,Mundra Solar PV Limited (Adani),Mono-c-Si,1,550.0,518.2,2.57,,,72.0,13.87,50.2,13.1,42.0,0.005464779999999999,-0.1198274,45.56,1.7419243721338142,13.883398433601592,4.1610045723981114e-12,0.20416768752151973,211.35350004309348,3.2253145952731144,-0.2987,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-M10-144-555,Mundra Solar PV Limited (Adani),Mono-c-Si,1,555.0,523.0,2.57,,,72.0,13.93,50.4,13.16,42.2,0.00548842,-0.1203048,45.56,1.7493039829050236,13.94307808280415,4.210334024533095e-12,0.20128821359777452,214.40029560107712,3.287987530436641,-0.2987,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-M10-144-560,Mundra Solar PV Limited (Adani),Mono-c-Si,1,560.0,527.9,2.57,,,72.0,13.99,50.6,13.21,42.4,0.005512059999999999,-0.12078219999999999,45.56,1.7572874212259755,14.003465750701695,4.298475310974755e-12,0.1983893978785844,206.11310362044316,3.430448376346195,-0.2987,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-M10-144-565,Mundra Solar PV Limited (Adani),Mono-c-Si,1,565.0,532.7,2.57,,,72.0,14.0,50.8,13.27,42.6,0.005516,-0.1212596,45.56,1.7618169755620532,14.009828929398093,4.1531621746333575e-12,0.1964811578200039,279.8612242340201,3.114303326763584,-0.2987,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-M10-144-570,Mundra Solar PV Limited (Adani),Mono-c-Si,1,570.0,537.5,2.57,,,72.0,14.11,51.0,13.32,42.8,0.005559339999999999,-0.121737,45.56,1.7726508088474864,14.123512495918966,4.4383494462407485e-12,0.19270723116627086,201.22848151545705,3.6324013725954467,-0.2987,N,2025.7.3,6/23/2025,4.0,bootstrapping +Mundra Solar PV Limited (Adani) ASB-M10-144-575,Mundra Solar PV Limited (Adani),Mono-c-Si,1,575.0,542.4,2.57,,,72.0,14.17,51.2,13.38,43.0,0.0055829799999999995,-0.1222144,45.56,1.7800287429740052,14.183193114476534,4.4890606786497384e-12,0.18992791570009035,203.99114837342776,3.692293461941748,-0.2987,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) ASB-M10-144-580,Mundra Solar PV Limited (Adani),Mono-c-Si,1,580.0,547.2,2.57,,,72.0,14.24,51.4,13.43,43.2,0.00561056,-0.1226918,45.56,1.7885897701536255,14.254171487293945,4.6226238085356066e-12,0.186934932824427,187.83867783766073,3.9065944703822377,-0.2987,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-590,Mundra Solar PV Limited (Adani),Mono-c-Si,1,590.0,556.9,2.68,,,66.0,15.72,47.8,14.87,39.7,0.00661812,-0.1109438,46.25,1.625070237970726,15.735812480396818,2.6046456083742244e-12,0.19802337126121675,196.86521790153446,1.0433921691283632,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-595,Mundra Solar PV Limited (Adani),Mono-c-Si,1,595.0,561.7,2.68,,,66.0,15.76,48.1,14.89,40.0,0.00663496,-0.1116401,46.25,1.637096857243956,15.777121564255872,2.694358501977629e-12,0.19487041715911327,179.3736676469288,1.3127542994707293,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-600,Mundra Solar PV Limited (Adani),Mono-c-Si,1,600.0,566.5,2.68,,,66.0,15.8,48.4,14.91,40.3,0.0066518,-0.1123364,46.25,1.6491375623473707,15.818363846726882,2.7865268939814925e-12,0.19172205970012118,164.95501118944603,1.5808085878876539,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-605,Mundra Solar PV Limited (Adani),Mono-c-Si,1,605.0,571.4,2.68,,,66.0,15.83,48.7,14.94,40.5,0.00666443,-0.11303270000000001,46.25,1.658328017450518,15.848526763117716,2.7419848484638024e-12,0.19633308968593274,167.75476392226474,1.427958115105176,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-610,Mundra Solar PV Limited (Adani),Mono-c-Si,1,610.0,576.2,2.68,,,66.0,15.86,49.0,14.96,40.8,0.006677059999999999,-0.113729,46.25,1.669916760159841,15.878966999975427,2.812188529676533e-12,0.19332393180849927,161.65537809446184,1.6282124830356324,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-615,Mundra Solar PV Limited (Adani),Mono-c-Si,1,615.0,581.0,2.68,,,66.0,15.89,49.3,14.98,41.1,0.006689690000000001,-0.1144253,46.25,1.6815113113442401,15.909376146684314,2.8835229802946275e-12,0.1903214929977707,156.0789442761141,1.8268543058396578,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Mundra Solar PV Limited (Adani) AB-G12R-132-620,Mundra Solar PV Limited (Adani),Mono-c-Si,1,620.0,585.9,2.68,,,66.0,15.91,49.6,14.99,41.4,0.006698109999999999,-0.11512160000000002,46.25,1.6931406988207778,15.92978734190928,2.9554908947157966e-12,0.18744229831789475,150.7128639146063,2.027961753529726,-0.2839,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE295-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,295.0,271.1,1.67,,,60.0,9.66,40.1,9.16,32.3,0.00488796,-0.11195920000000001,46.9,1.5035302701135431,9.662881705893758,2.516049197788397e-11,0.35694734356714275,1196.552227141599,4.950685632631635,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE300-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,300.0,275.8,1.67,,,60.0,9.75,40.2,9.26,32.4,0.0049335,-0.1122384,46.9,1.5066340820746924,9.751254997615286,2.5151449313190233e-11,0.35201256015488486,2734.7601650437896,4.862708336089661,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE305-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,305.0,280.6,1.67,,,60.0,9.86,40.3,9.36,32.6,0.004989159999999999,-0.1125176,46.9,1.5135884448346133,9.862056797787845,2.6888383959952524e-11,0.33419075267983156,1602.0637468553475,5.338792785673616,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE310-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,310.0,285.3,1.67,,,60.0,9.95,40.5,9.45,32.8,0.0050347,-0.11307600000000001,46.9,1.5216722530408602,9.951660045363676,2.7418927710676254e-11,0.3281102823309903,1966.6316156807047,5.426438321395643,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE315-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,315.0,290.0,1.67,,,60.0,10.07,40.6,9.55,33.0,0.005095420000000001,-0.1133552,46.9,1.5293385804649404,10.07336735360506,2.964055223624126e-11,0.3106056980787889,928.8598501002429,5.997746825916625,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE315-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,315.0,290.1,1.92,,,24.0,8.79,46.7,8.43,37.6,0.0053003699999999996,-0.1330483,46.0,1.7717711279645538,8.790003722838705,3.140052291359645e-11,0.4078929643428907,963129.274525663,5.3629303304160745,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE320-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,320.0,294.8,1.67,,,60.0,10.18,40.7,9.65,33.2,0.00515108,-0.11363440000000001,46.9,1.5362816582090637,10.183964736013987,3.162617790949448e-11,0.29376602864828,754.2843468556899,6.464865165004307,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE320-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,320.0,294.8,1.92,,,24.0,8.89,46.8,8.54,37.7,0.0053606700000000005,-0.13333319999999999,46.0,1.7772777250082974,8.890003621857801,3.257471372539494e-11,0.39236104450545334,963119.4327412307,5.579883227190648,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE325-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,325.0,299.5,1.67,,,60.0,10.27,40.8,9.75,33.3,0.00519662,-0.11391359999999999,46.9,1.5393922557666462,10.272588423544835,3.159734642638194e-11,0.28973034294946803,1149.5532733460118,6.375242327954302,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE325-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,325.0,299.5,1.92,,,24.0,8.99,46.9,8.64,37.8,0.005420970000000001,-0.1336181,46.0,1.7818405772757404,8.990003587776904,3.3315781156417555e-11,0.3838045090367718,961762.7166859481,5.676616882155284,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE330-60MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,330.0,304.2,1.67,,,60.0,10.37,41.0,9.86,33.5,0.00524722,-0.114472,46.9,1.546692315954902,10.371225511899517,3.182426563474776e-11,0.2840416663295211,2403.495667562599,6.347532839925648,-0.3675,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE330-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,330.0,304.2,1.92,,,24.0,9.08,47.0,8.74,37.9,0.00547524,-0.133903,46.0,1.7872814757817261,9.080003487516398,3.447275091251999e-11,0.36942682644570146,961881.2209493004,5.883696780234088,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE335-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,335.0,309.0,1.92,,,24.0,9.18,47.1,8.82,38.0,0.005535539999999999,-0.1341879,46.0,1.7900038917624468,9.18000358809163,3.4303637610396206e-11,0.3744405171323611,958044.9028461098,5.7477154478104895,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE340-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,340.0,313.7,1.92,,,24.0,9.27,47.2,8.93,38.1,0.00558981,-0.1344728,46.0,1.7963326914775388,9.270003421431285,3.59469153120815e-11,0.35407109781284146,959369.4350353427,6.0652955483246735,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE345-72PV,New East Solar Energy (Cambodia) CoLtd,Multi-c-Si,0,345.0,318.4,1.92,,,24.0,9.38,47.3,9.04,38.2,0.0056561400000000005,-0.13475769999999998,46.0,1.8009002218538934,9.380003386063166,3.677998290966277e-11,0.3457423583040583,957820.0341115913,6.160774680014773,-0.3665,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE355-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,355.0,331.7,1.92,,,24.0,9.59,48.1,9.04,39.3,0.00395108,-0.12578150000000002,44.3,1.751335474972987,9.600548822328971,1.1171572493760347e-11,0.3773106844064268,343.015492823125,5.184262764695878,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE360-60MH-M6,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,360.0,338.0,1.8,,,60.0,11.24,40.6,10.66,33.8,0.006654080000000001,-0.1046262,44.7,1.4764380454677655,11.245902538457248,1.272010363924459e-11,0.20641291169715978,393.06497189786506,6.230978166315222,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE360-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,360.0,336.5,1.92,,,24.0,9.69,48.2,9.15,39.4,0.00399228,-0.12604300000000002,44.3,1.7539787894234793,9.699061709241098,1.113503642717742e-11,0.37187495321706937,397.6587894094245,5.060396013275778,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE365-60MH-M6,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,365.0,342.8,1.8,,,60.0,11.33,40.8,10.74,34.0,0.00670736,-0.10514159999999999,44.7,1.4847843741926674,11.336292056081119,1.307049940171135e-11,0.2021768308491819,364.0564358433739,6.4000033152759634,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE365-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,365.0,341.2,1.92,,,24.0,9.78,48.3,9.24,39.5,0.00402936,-0.12630450000000001,44.3,1.757581046381969,9.788627033479296,1.1238638520012283e-11,0.36693856162981553,415.9783513877871,5.058366824017952,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE370-60MH-M6,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,370.0,347.6,1.8,,,60.0,11.42,41.0,10.82,34.2,0.00676064,-0.105657,44.7,1.4931300778096461,11.42666414700745,1.3426698374498976e-11,0.19800383617184647,339.30881503584527,6.567293859007514,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE370-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,370.0,346.0,1.92,,,24.0,9.87,48.4,9.34,39.6,0.00406644,-0.126566,44.3,1.7603147475686196,9.877218895482573,1.1203450565252337e-11,0.3620893957284853,495.0649834401737,4.946642832627445,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE375-60MH-M6,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,375.0,352.5,1.8,,,60.0,11.51,41.2,10.91,34.4,0.00681392,-0.1061724,44.7,1.5008262927441753,11.516320416935006,1.3640750171695475e-11,0.19396107857980296,353.21910263999564,6.635077574952216,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE375-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,375.0,350.8,1.92,,,24.0,9.99,48.6,9.45,39.7,0.004115880000000001,-0.127089,44.3,1.7664829975439258,9.997701064065422,1.1143072293718661e-11,0.36696868591474635,476.0403469059952,4.798546354891235,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE380-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,380.0,355.6,1.92,,,24.0,10.08,48.7,9.55,39.8,0.00415296,-0.1273505,44.3,1.7692512271373826,10.08627762872464,1.1112736095759317e-11,0.36221054451975854,581.6021452277367,4.692379016191044,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE385-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,385.0,360.4,1.92,,,24.0,10.18,48.8,9.65,39.9,0.00419416,-0.127612,44.3,1.7728434894654501,10.185816621686694,1.1222533680464574e-11,0.3572029655225006,625.161207386948,4.689850212133928,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE390-72MV,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,390.0,365.2,1.92,,,24.0,10.28,48.9,9.75,40.0,0.0042353600000000005,-0.1278735,44.3,1.7764426104077762,10.285361999603758,1.1333413084584879e-11,0.3522954063239157,675.4190779149777,4.688183248523516,-0.3432,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE395-54MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,395.0,370.0,1.94,,,54.0,13.63,36.9,12.87,30.7,0.00806896,-0.0938736,45.3,1.3498805285239694,13.641200517482305,1.806441563719232e-11,0.15527429552796068,188.95454290097214,9.034354474173089,-0.3255,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE400-54MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,400.0,374.8,1.94,,,54.0,13.7,37.1,12.95,30.9,0.008110399999999999,-0.0943824,45.3,1.3572440597290154,13.710101164290819,1.8195449043521716e-11,0.15239434941611876,206.68930241889916,9.048840203662705,-0.3255,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE405-54MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,405.0,379.6,1.94,,,54.0,13.77,37.3,13.03,31.1,0.00815184,-0.09489120000000001,45.3,1.3646066693308576,13.779040305333035,1.8326189810843947e-11,0.1495505410353454,227.7921916852758,9.062986236187697,-0.3255,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE410-54MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,410.0,384.4,1.94,,,54.0,13.84,37.5,13.1,31.3,0.00819328,-0.09540000000000001,45.3,1.3724614508087714,13.848715791253651,1.8622107061575196e-11,0.14669837191122198,232.94562917757403,9.159493627057193,-0.3255,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE415-54MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,415.0,389.2,1.94,,,54.0,13.91,37.7,13.18,31.5,0.008234720000000001,-0.09590880000000002,45.3,1.3798215900542325,13.917715092189457,1.875230236430284e-11,0.14392321379898138,259.4877508496686,9.172332094005421,-0.3255,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE415-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,415.0,393.2,1.94,,,54.0,14.04,37.8,13.26,31.3,0.0049757759999999995,-0.08981658,43.7,1.2984673588412257,14.055677461129012,3.145810255402373e-12,0.18097812710574865,162.0755354934608,1.2888748459770507,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE420-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,420.0,398.1,1.94,,,54.0,14.11,38.0,13.34,31.5,0.005000584,-0.09029179999999999,43.7,1.30540251867634,14.124386758288177,3.1696050212500496e-12,0.17810442726551112,174.67822991216715,1.3059445007244335,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE425-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,425.0,402.9,1.94,,,54.0,14.18,38.2,13.41,31.7,0.005025392,-0.09076702,43.7,1.3127711234188817,14.193980817978597,3.22145109136505e-12,0.17525764611623706,177.75450827959554,1.3994864158882112,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE435-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,435.0,412.6,1.94,,,54.0,14.32,38.6,13.56,32.1,0.005075008,-0.09171746,43.7,1.3270701159405003,14.332378458897624,3.297267071141313e-12,0.1696669161357581,196.27888473851698,1.5068779575977935,-0.29831,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE440-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,440.0,417.5,1.94,,,54.0,14.39,38.8,13.63,32.3,0.005099816,-0.09219267999999999,43.7,1.3344354494002535,14.402011831876088,3.3496573529849012e-12,0.16691155456525839,199.95761669480692,1.597383759882051,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE440-60MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,440.0,413.4,2.14,,,60.0,13.64,41.0,12.91,34.1,0.008484080000000001,-0.10409900000000001,44.7,1.4955198034060873,13.649050482698927,1.6742470938624375e-11,0.1739338690362752,262.13607273630834,8.518940044712375,-0.3215,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE445-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,445.0,422.3,1.94,,,54.0,14.46,39.0,13.7,32.5,0.005124624,-0.0926679,43.7,1.884747498075817,14.460071353634811,9.990007371998942e-14,2.3486890903292306,525194.7974883369,99.9999606948976,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE445-60MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,445.0,418.2,2.14,,,60.0,13.71,41.2,12.98,34.3,0.00852762,-0.10460680000000001,44.7,1.5033431937214894,13.718732953059318,1.6995415980973524e-11,0.1709313940074742,268.34787882431436,8.605568212461467,-0.3215,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE450-54THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,450.0,427.2,1.94,,,54.0,14.53,39.2,13.77,32.7,0.005149431999999999,-0.09314312,43.7,1.3491636239339446,14.541301633028386,3.455291924033593e-12,0.16148670480014607,207.61617559522045,1.7751045826699454,-0.29831,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE450-60MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,450.0,423.0,2.14,,,60.0,13.78,41.4,13.05,34.5,0.00857116,-0.1051146,44.7,1.5111657269412921,13.78842283659641,1.7249705276699553e-11,0.16796173703716724,274.79017633238243,8.691222220886008,-0.3215,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE455-60MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,455.0,427.8,2.14,,,60.0,13.85,41.6,13.12,34.7,0.008614700000000001,-0.10562240000000002,44.7,1.5189873863306558,13.858119985219242,1.7505317193413087e-11,0.16502436662290113,281.47680490281203,8.775913833728513,-0.3215,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE460-60MH-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,460.0,432.6,2.14,,,60.0,13.92,41.8,13.19,34.9,0.00865824,-0.10613020000000001,44.7,1.5268082182927978,13.927824300156386,1.7762248970279567e-11,0.16211875332510653,288.4208900246864,8.85966374078313,-0.3215,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE530-72MHB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,1,530.0,500.1,2.56,,,72.0,13.65,49.4,12.91,41.1,0.00795795,-0.12527839999999998,43.1,1.8069952222372219,13.659610306110563,1.8081916774235193e-11,0.20744113767413883,294.6390588268447,9.381832407282857,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE530-72MHT-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,530.0,496.9,2.56,,,72.0,13.65,49.4,12.91,41.1,0.0046683,-0.141778,43.9,1.8134566641798224,13.659420319283194,1.9935175591252802e-11,0.20632986083657173,298.971036814774,-2.3498532367440137,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE535-72MHB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,1,535.0,504.9,2.56,,,72.0,13.71,49.6,12.96,41.3,0.00799293,-0.1257856,43.1,1.8154887750023914,13.720062716580307,1.8473643382454548e-11,0.20436152828643128,278.43330369150846,9.536457720656271,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE535-72MHT-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,535.0,501.7,2.56,,,72.0,13.71,49.6,12.96,41.3,0.00468882,-0.142352,43.9,1.8220140602438846,13.719870281429882,2.0375959482855676e-11,0.20324280417670781,282.30794493585205,-2.2090536349419603,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE540-72MHB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,1,540.0,509.8,2.56,,,72.0,13.77,49.8,13.02,41.5,0.00802791,-0.12629279999999998,43.1,1.8233230479048619,13.779777893929136,1.870196302670076e-11,0.2013606669081652,283.57194451540124,9.60634990151715,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE540-72MHT-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,540.0,506.5,2.56,,,72.0,13.77,49.8,13.02,41.5,0.00470934,-0.142926,43.9,1.8298893005503556,13.779587485656334,2.0631154950094195e-11,0.20023951344778038,287.59345467138064,-2.1458000473451446,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE545-72MHB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,1,545.0,514.6,2.56,,,72.0,13.83,51.8,13.08,41.7,0.00806289,-0.1313648,43.1,1.8640246097968223,13.841330575626438,1.1707396189641327e-11,0.3374792726012989,411.9242082861175,5.442658830669638,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE545-72MHT-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,545.0,511.3,2.56,,,72.0,13.83,50.0,13.07,41.7,0.004729860000000001,-0.1435,43.9,1.8384484125111615,13.840014169841135,2.108125306072338e-11,0.19720161149098547,272.3439234882704,-2.0067430668485664,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE550-72MHB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,1,550.0,519.4,2.56,,,72.0,13.89,50.2,13.13,41.9,0.00809787,-0.1273072,43.1,1.839650750141775,13.899922041250477,1.933320872359651e-11,0.19538292656190367,273.5192096818233,9.827278501872343,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE550-72MHT-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,550.0,516.1,2.56,,,72.0,13.89,50.2,13.13,41.9,0.00475038,-0.14407399999999998,43.9,1.8463227919069185,13.899731183216538,2.1340378555581393e-11,0.19425187910219605,277.26932688887126,-1.9448959483781405,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE560-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,560.0,532.1,2.56,,,72.0,14.11,50.7,13.34,42.0,0.005222111000000001,-0.12116286,43.0,1.7414930914845708,14.124466072487397,3.1598452577360716e-12,0.23992676240851687,234.0211299186711,0.6729708954859042,-0.29679,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE565-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,565.0,537.0,2.56,,,72.0,14.17,50.9,13.39,42.2,0.005244317,-0.12164082,43.0,1.7494219374833402,14.184990571286292,3.2275673029167424e-12,0.23693191636530608,223.96246243511516,0.8168026510691024,-0.29679,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE570-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,570.0,541.9,2.56,,,72.0,14.23,51.1,13.45,42.4,0.005266523,-0.12211878,43.0,1.7567696852586572,14.24465092280971,3.2674588066647158e-12,0.23397055132962236,227.2485487468768,0.8831935082082565,-0.29679,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE575-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,575.0,546.7,2.56,,,72.0,14.29,51.3,13.5,42.6,0.005288729,-0.12259674,43.0,1.764699813106256,14.30515228767783,3.336573630861158e-12,0.23102213791651388,217.8751105419787,1.0252931757636476,-0.29679,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE580-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,580.0,551.6,2.56,,,72.0,14.35,51.5,13.56,42.8,0.005310935,-0.1230747,43.0,1.7720467703187328,14.364812499529815,3.3770687359267937e-12,0.22811174872335546,220.98927937902465,1.0901921933216898,-0.29679,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE585-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,585.0,545.5,2.56,,,72.0,14.41,51.7,13.61,43.0,0.01763784,-0.16164005,43.1,2.1961134974551713,14.413828631284451,8.55416920014762e-10,0.15847147397167835,596.446803527744,19.724281026864883,-0.40828,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE590-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,590.0,550.3,2.56,,,72.0,14.47,51.9,13.66,43.2,0.017711280000000003,-0.16226535,43.1,2.206113742763498,14.474202789436228,8.723013683655226e-10,0.15545762595860296,535.2332561847285,19.877277434498968,-0.40828,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE595-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,595.0,555.1,2.56,,,72.0,14.53,52.1,13.72,43.4,0.017784719999999997,-0.16289065,43.1,2.2152740914883013,14.534006148295338,8.822536059998869e-10,0.15258961854757444,553.4313345655609,19.9474798951833,-0.40828,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE600-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,600.0,571.7,2.69,,,66.0,15.85,48.1,14.93,40.2,0.00646997,-0.11157757000000001,43.3,1.6300573826954519,15.870196719190389,2.376603329790304e-12,0.18050277521888536,141.655134766449,0.3069812076278415,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE600-72THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,600.0,559.9,2.56,,,72.0,14.59,52.3,13.77,43.6,0.017858159999999998,-0.16351595,43.1,2.2252746016859324,14.59435746586109,8.994287226597028e-10,0.14962129793351203,500.9736169357357,20.098483576376182,-0.40828,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE605-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,605.0,576.6,2.69,,,66.0,15.9,48.3,14.98,40.4,0.0064903800000000005,-0.11204151,43.3,1.6373117372428978,15.91981578051748,2.4050346248050553e-12,0.17820183903502065,142.98751642691778,0.37941042728168595,-0.27869,N,2025.7.3,6/23/2025,2.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE610-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,610.0,581.5,2.69,,,66.0,15.95,48.5,15.03,40.6,0.006510790000000001,-0.11250545,43.3,1.6445653431792577,15.969440125919649,2.4335633540359393e-12,0.1759166679383093,144.33398448020256,0.45113303094150936,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE610-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,610.0,581.4,2.77,,,78.0,14.11,55.1,13.35,45.7,0.006120918,-0.12493925000000002,43.5,1.8466012597247607,14.124974715336311,1.5289133608035072e-12,0.26399231780073706,248.7480745574891,-0.17463082146752668,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE615-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,615.0,586.3,2.69,,,66.0,16.0,48.7,15.08,40.8,0.006531200000000001,-0.11296939000000002,43.3,1.6518178776385009,16.019069516737115,2.4621742932736672e-12,0.1736471467720096,145.6961057971329,0.5221104025935118,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE615-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,615.0,586.3,2.77,,,78.0,14.16,55.3,13.4,45.9,0.006142608000000001,-0.12539275,43.5,1.853772938241469,14.174685608382136,1.5462133618990184e-12,0.2611273499709333,251.78141632904078,-0.11079034873820741,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE620-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,620.0,591.2,2.69,,,66.0,16.05,48.9,15.13,41.0,0.00655161,-0.11343333,43.3,1.6590696434095205,16.06870409890118,2.4908785181369196e-12,0.1713930727330534,147.0725102786143,0.5923956864482962,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE620-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,620.0,591.2,2.77,,,78.0,14.21,55.5,13.45,46.1,0.006164298,-0.12584625000000002,43.5,1.8609440263232102,14.224400610959385,1.5635822909442892e-12,0.2582841233444502,254.86539283052872,-0.0474881316841568,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE625-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,625.0,596.1,2.69,,,66.0,16.09,49.1,15.17,41.2,0.006567938000000001,-0.11389727000000001,43.3,1.6663491886373771,16.108373298135817,2.5192693030358066e-12,0.16925766608409148,148.22357024720245,0.6660278996827936,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE625-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,625.0,596.0,2.77,,,78.0,14.26,55.7,13.5,46.3,0.006185988000000001,-0.12629975000000002,43.5,1.868114524203687,14.274119667593181,1.5810194962353013e-12,0.2554623916429209,258.0013788125446,0.015281506003842161,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE630-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,630.0,600.9,2.69,,,66.0,16.14,49.3,15.22,41.4,0.006588348000000001,-0.11436121,43.3,1.673599455265173,16.15801760600529,2.548152282252498e-12,0.16703221350635922,149.6258671683357,0.7349437013669163,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE630-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,630.0,600.9,2.77,,,78.0,14.31,55.9,13.55,46.5,0.006207678,-0.12675325,43.5,1.8752844338462393,14.323842725656704,1.598524370457643e-12,0.25266191186894293,261.1907528998178,0.07752477312340549,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE635-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,635.0,602.4,3.08,,,66.0,18.11,44.6,17.12,37.1,0.009257832,-0.18499634,42.4,1.6257206227562357,18.123647538572943,2.1783122259364252e-11,0.14234399421390234,188.8875226260656,-33.78294241921053,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE635-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,635.0,605.8,2.69,,,66.0,16.19,49.5,15.27,41.6,0.006608758000000001,-0.11482515,43.3,1.6808488754507886,16.2076668336154,2.5771208225425404e-12,0.16482177464653644,151.04373478490388,0.803181303663431,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,635.0,605.8,2.77,,,78.0,14.36,56.1,13.6,46.7,0.006229368000000001,-0.12720675,43.5,1.8824537790486648,14.373569750238936,1.6160968399977077e-12,0.24988244143251964,264.43462813673307,0.1392504235174891,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE640-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,640.0,607.3,3.08,,,66.0,18.17,44.8,17.17,37.3,0.009288504000000001,-0.18582591999999998,42.4,1.634163284048591,18.18404696848005,2.2270198206624052e-11,0.14023152419655702,181.39193612253257,-33.680198516318264,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE640-66THB-G12R,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,640.0,610.7,2.69,,,66.0,16.24,49.7,15.32,41.8,0.0066291679999999995,-0.11528909000000001,43.3,1.6880976262618712,16.25732104766338,2.606181057509602e-12,0.1626261734820476,152.476287564353,0.8707741062752783,-0.27869,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE640-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,640.0,610.6,2.77,,,78.0,14.41,56.3,13.65,46.9,0.006251058,-0.12766025,43.5,1.8896225526022647,14.423300682672194,1.6337360874173034e-12,0.2471237462268171,267.73461615479334,0.20046281959742654,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE645-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,645.0,612.1,3.08,,,66.0,18.22,45.0,17.21,37.5,0.009314064,-0.1866555,42.4,1.642636224953949,18.234458540601455,2.2761593534655042e-11,0.13820502596777842,174.1597341579392,-33.57602533399702,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE645-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,645.0,615.5,2.77,,,78.0,14.46,56.5,13.7,47.1,0.006272748000000001,-0.12811375000000003,43.5,1.89679074978742,14.473035467899468,1.6514413550186896e-12,0.24438559519561687,271.09235597805076,0.2611667577301211,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE650-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,650.0,616.9,3.08,,,66.0,18.27,45.2,17.25,37.7,0.009339624,-0.18748508,42.4,1.6511121849021815,18.28484933539695,2.3260209902013866e-11,0.13618737947675547,167.55924560401954,-33.47251158908133,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE650-78THB-M10,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,650.0,620.4,2.77,,,78.0,14.51,56.7,13.75,47.3,0.006294438,-0.12856725000000002,43.5,1.9039584303131998,14.522774099522383,1.6692134828075325e-12,0.24166775072294716,274.5085121942591,0.3213756558633123,-0.27256,N,2025.7.3,6/23/2025,4.0,first_pass +New East Solar Energy (Cambodia) CoLtd NESE655-66MHB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,655.0,619.8,3.08,,,66.0,18.32,45.4,17.29,37.9,0.007958208,-0.10806108,43.4,1.601963522214043,18.337852863081093,8.869250742957741e-12,0.14166369709047655,145.37046098068762,7.614295535001646,-0.30967,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE655-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,655.0,621.8,3.08,,,66.0,18.32,45.4,17.29,37.9,0.009365184,-0.18831466,42.4,1.6595911488304007,18.33521969373589,2.3766095108503252e-11,0.1341785248183781,161.51117298242687,-33.36965202976097,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE660-66MHB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,660.0,624.7,3.08,,,66.0,18.37,45.6,17.33,38.1,0.007979928,-0.10853712000000001,43.4,1.6099951131123418,18.388217871247615,9.042214552385758e-12,0.13971002396045912,140.87667599855416,7.7630633348867795,-0.30967,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE660-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,660.0,626.6,3.08,,,66.0,18.37,45.6,17.33,38.1,0.009390744,-0.18914424,42.4,1.6680731066401049,18.38556994896262,2.4279298130312813e-11,0.13217840399471334,155.9489565258613,-33.267445087714854,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE665-66MHB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,665.0,629.5,3.08,,,66.0,18.42,45.8,17.37,38.3,0.008001648000000002,-0.10901316,43.4,1.6180289408391195,18.43856339048413,9.217305937182876e-12,0.13776492682097408,136.70077990319092,7.910889393686751,-0.30967,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE665-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,665.0,631.5,3.08,,,66.0,18.42,45.8,17.37,38.3,0.009416304000000002,-0.18997382,42.4,1.6765580169277925,18.435900425685517,2.4799858867990502e-11,0.13018694923750143,150.81631399762014,-33.16586489634109,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE670-66MHB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,670.0,634.4,3.08,,,66.0,18.47,46.0,17.41,38.5,0.008023368,-0.10948920000000001,43.4,1.6260650236033163,18.488889736435226,9.394537880274886e-12,0.13582835282628358,132.81020039572707,8.057753928791257,-0.30967,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE670-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,670.0,636.3,3.08,,,66.0,18.47,46.0,17.42,38.5,0.009441864,-0.1908034,42.4,1.684533692644732,18.485553287240542,2.5135371804946408e-11,0.12824700027325034,152.29720059904142,-33.107817915047555,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE675-66MHB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,675.0,639.2,3.08,,,66.0,18.52,46.2,17.45,38.7,0.008045088,-0.10996524,43.4,1.6341033529894293,18.539197216677,9.573919954525893e-12,0.1339002449908785,129.17667093961194,8.203662375007324,-0.30967,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE675-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,675.0,641.2,3.08,,,66.0,18.52,46.2,17.45,38.7,0.009467424,-0.19163298,42.4,1.6935367038676339,18.536503311228056,2.5863260774659493e-11,0.12622982820441192,141.65499257209166,-32.96461698401235,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE680-66MHT-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,680.0,646.1,3.08,,,66.0,18.57,46.4,17.49,38.9,0.009492984,-0.19246255999999998,42.4,1.702030433863781,18.58677633379625,2.6406190421726894e-11,0.12426403931216203,137.54991099606156,-32.864926020969065,-0.30941,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE685-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,685.0,650.9,3.08,,,66.0,18.15,47.7,17.17,39.9,0.00411279,-0.11417472000000001,43.2,1.614890404715932,18.167284190368125,2.6556029016447636e-12,0.15405262006710174,161.76951283180128,-2.7518314495433205,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE690-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,690.0,655.7,3.08,,,66.0,18.19,47.9,17.21,40.1,0.004121854,-0.11465344,43.2,1.6221790976732653,18.206985337922028,2.6868577868000397e-12,0.1522079956387105,163.00314162096257,-2.675567073925805,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE695-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,695.0,660.6,3.08,,,66.0,18.23,48.1,17.25,40.3,0.004130918,-0.11513216,43.2,1.6294670128678164,18.246689857798525,2.718201622987278e-12,0.15037226415984442,164.24863591716448,-2.59993577918388,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE700-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,700.0,665.5,3.08,,,66.0,18.27,48.3,17.29,40.5,0.004139982,-0.11561087999999999,43.2,1.6367542735880167,18.286397725773078,2.7496365073004574e-12,0.14854543237972923,165.50618598839174,-2.5251206613560955,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE705-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,705.0,670.3,3.08,,,66.0,18.31,48.5,17.33,40.7,0.004149046,-0.11608959999999999,43.2,1.6440407946552178,18.326108911192573,2.7811580475298783e-12,0.14672740017437846,166.7759333268422,-2.4509754695697716,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,710.0,675.2,3.08,,,66.0,18.35,48.7,17.37,40.9,0.0041581100000000005,-0.11656832,43.2,1.6513266281135903,18.365823395254786,2.812766464396818e-12,0.1449181051335382,168.05794126501584,-2.377551449791578,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE715-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,715.0,680.0,3.08,,,66.0,18.38,48.9,17.4,41.1,0.004164908,-0.11704703999999999,43.2,1.6586343812991184,18.395569270023056,2.8439548631063163e-12,0.1431940661681658,169.0449798890555,-2.3017127834412165,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE720-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,720.0,684.9,3.08,,,66.0,18.42,49.1,17.44,41.3,0.004173972000000001,-0.11752576,43.2,1.6659188576349964,18.435289796434372,2.875726134611248e-12,0.14140083502764028,170.34912102280947,-2.229684816193372,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE725-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,725.0,689.8,3.08,,,66.0,18.46,49.3,17.48,41.5,0.004183036,-0.11800448,43.2,1.6732026119420949,18.475013539072517,2.9075780083627686e-12,0.13961618427582873,171.6660376419704,-2.1583008671965698,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +New East Solar Energy (Cambodia) CoLtd NESE730-66THB-G12,New East Solar Energy (Cambodia) CoLtd,Mono-c-Si,0,730.0,694.7,3.08,,,66.0,18.49,49.5,17.51,41.7,0.004189834,-0.1184832,43.2,1.6805083944577748,18.5047671901637,2.9389879592649623e-12,0.13791308369212035,172.6809833819088,-2.084503481322776,-0.29588,N,2025.7.3,6/23/2025,4.0,bootstrapping +Next Energy Alliance LLC NEA265M-60,Next Energy Alliance LLC,Mono-c-Si,0,265.0,238.1,1.63,,,60.0,9.05,38.26,8.52,31.11,0.0057377,-0.13547866,46.6,1.6240732223684784,9.054170904651166,5.280668763343149e-10,0.28028422998856134,608.1586313110308,6.036979169559025,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA270M-60,Next Energy Alliance LLC,Mono-c-Si,0,270.0,242.7,1.63,,,60.0,9.17,38.46,8.62,31.33,0.00581378,-0.13618686000000002,46.6,1.6356449365472208,9.175351926258957,5.582354015640016e-10,0.2700462956702555,462.69796469339036,6.40745106967331,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA275M-60,Next Energy Alliance LLC,Mono-c-Si,0,275.0,247.3,1.63,,,60.0,9.25,38.86,8.73,31.51,0.0058645,-0.13760326,46.6,1.6446646604507658,9.252210512433903,5.049742361245628e-10,0.2906539046126313,1216.2569589378252,5.45743591817908,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA280M-60,Next Energy Alliance LLC,Mono-c-Si,0,280.0,252.0,1.63,,,60.0,9.37,39.05,8.84,31.68,0.005940579999999999,-0.13827604999999998,46.6,1.6535159446788723,9.372563454914495,5.17222716102302e-10,0.28617507967076516,1046.0346644090296,5.553483614513898,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA285M-60,Next Energy Alliance LLC,Mono-c-Si,0,285.0,256.6,1.63,,,60.0,9.49,39.25,8.95,31.85,0.00601666,-0.13898425,46.6,1.6625393759609615,9.492902408753316,5.277501681602507e-10,0.28295165323405774,925.1671006045988,5.61826229262858,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA290M-60,Next Energy Alliance LLC,Mono-c-Si,0,290.0,261.3,1.63,,,60.0,9.6,39.46,9.06,32.07,0.0060864,-0.13972786,46.6,1.6723267251227296,9.60242378047849,5.409821493615114e-10,0.2747951060779446,1088.3964303913538,5.729688336032142,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA295M-60,Next Energy Alliance LLC,Mono-c-Si,0,295.0,265.9,1.63,,,60.0,9.72,39.64,9.14,32.29,0.0061624800000000006,-0.14036524000000003,46.6,1.6854920325423866,9.725415548141417,5.891784953520707e-10,0.26277773378783686,471.6421109860132,6.369257400821876,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA300M-60,Next Energy Alliance LLC,Mono-c-Si,0,300.0,270.6,1.63,,,60.0,9.84,39.82,9.23,32.51,0.00623856,-0.14100262000000002,46.6,1.6976732378803763,9.847334339655337,6.330267661241469e-10,0.25108960745190123,336.8704688223921,6.89268259678697,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA305M-60,Next Energy Alliance LLC,Mono-c-Si,0,305.0,280.2,1.63,,,60.0,9.96,40.0,9.32,32.73,0.006513840000000001,-0.13355999999999998,44.9,1.6353177831922803,9.971363206140543,2.333744464340258e-10,0.25632005447654843,224.66792459457955,4.510452338608254,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA310M-60,Next Energy Alliance LLC,Mono-c-Si,0,310.0,285.0,1.63,,,60.0,10.08,40.18,9.41,32.95,0.00659232,-0.13416102,44.9,1.6468453238137426,10.093034785905633,2.505044677542328e-10,0.24509686879267495,189.53718312600037,5.017705368365235,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA315M-60,Next Energy Alliance LLC,Mono-c-Si,0,315.0,289.7,1.63,,,60.0,10.04,40.7,9.49,33.2,0.00656616,-0.1358973,44.9,1.652229682042404,10.043296347975405,2.0026672387932908e-10,0.2723436780732391,829.5032112026145,3.124195576845302,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA320M-60,Next Energy Alliance LLC,Mono-c-Si,0,320.0,294.4,1.63,,,60.0,10.15,40.9,9.59,33.4,0.0066381,-0.1365651,44.9,1.6617427470894528,10.153710815987571,2.065614333508441e-10,0.26618262093778017,728.0755022643596,3.293185921138251,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA365M-72,Next Energy Alliance LLC,Mono-c-Si,0,365.0,335.4,1.94,,,72.0,9.93,48.01,9.29,39.29,0.00649422,-0.16030539,44.9,1.9631739824012493,9.941473893410356,2.337253129158977e-10,0.30781768962088724,266.39865188486493,4.549391493921933,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA370M-72,Next Energy Alliance LLC,Mono-c-Si,0,370.0,340.1,1.94,,,72.0,10.03,48.23,9.37,39.51,0.00655962,-0.16103996999999998,44.9,1.9748414203618292,10.04258501631383,2.4357287890569736e-10,0.3009627182491128,239.86113294038213,4.819095449211141,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA375M-72,Next Energy Alliance LLC,Mono-c-Si,0,375.0,344.9,1.94,,,72.0,10.12,48.45,9.44,39.73,0.0066184799999999995,-0.16177455,44.9,1.986582446622832,10.13369131832345,2.5367677331502575e-10,0.2945056805098349,217.68522279946262,5.093578248105557,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA380M-72,Next Energy Alliance LLC,Mono-c-Si,0,380.0,349.6,1.94,,,72.0,10.22,48.67,9.52,39.95,0.0066838800000000005,-0.16250913,44.9,1.9982464493683993,10.234710206733574,2.6411559097050875e-10,0.2878715030890471,200.00038016427231,5.358077615257439,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Next Energy Alliance LLC NEA385M-72,Next Energy Alliance LLC,Mono-c-Si,0,385.0,354.4,1.94,,,72.0,10.31,48.89,9.59,40.17,0.0067427400000000005,-0.16324371,44.9,2.009987489467222,10.325723487214244,2.748289844279505e-10,0.2816105247815675,184.6539915308944,5.627694358199251,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH108-395-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,395.0,371.2,1.97,,,54.0,13.34,36.6,12.33,32.05,0.0037752199999999997,-0.09175620000000001,43.3,1.3710128120674805,13.342199281375462,3.253896760530619e-11,0.010524525296043185,63.837747142978294,16.82135371199106,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH108-400-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,400.0,376.0,1.97,,,54.0,13.42,36.8,12.45,32.13,0.00379786,-0.0922576,43.3,1.3737119583328674,13.423810311627813,2.9960732831026526e-11,0.020130708634926376,70.90079163033346,15.969984927917087,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH108-405-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,405.0,380.8,1.97,,,54.0,13.52,37.0,12.54,32.31,0.0038261599999999995,-0.092759,43.3,1.3814562620791666,13.523760411469008,3.03391138413151e-11,0.01955043933469177,70.29069622001292,16.019156823733212,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH120-440-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,440.0,413.5,2.18,,,60.0,13.55,40.81,12.31,35.75,0.00383465,-0.10231066999999999,43.3,1.5435106869845692,13.551548309746945,4.182403516876923e-11,0.005523479496039035,48.33861404127219,19.14704502057289,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH120-445-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,445.0,418.3,2.18,,,60.0,13.65,40.9,12.43,35.82,0.00386295,-0.10253629999999998,43.3,1.544690512334412,13.651900159056598,4.0672952825314795e-11,0.006987471331426546,50.19526311454402,18.797202007337315,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH120-450-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,450.0,423.1,2.18,,,60.0,13.67,41.05,12.53,35.92,0.00386861,-0.10291234999999999,43.3,1.544068689730995,13.672791506539385,3.685728832930874e-11,0.011711266599987462,57.35004113833897,17.8107533837014,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH120-455-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,455.0,427.9,2.18,,,60.0,13.69,41.15,12.64,36.01,0.0038742699999999995,-0.10316304999999999,43.3,1.5417991527447061,13.692705394333778,3.355294962715484e-11,0.013449648926859322,68.05872689220654,16.871571884894042,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH120-460-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,460.0,432.8,2.18,,,60.0,13.71,41.55,12.74,36.11,0.0038799299999999998,-0.10416584999999999,43.3,1.5460441952462647,13.71623677375756,2.814224603317771e-11,0.0376484133748837,82.76069781368089,15.176135000302281,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-525-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,525.0,493.3,2.61,,,72.0,13.74,48.7,12.28,42.75,0.0038884199999999996,-0.1220909,43.3,1.857105474350087,13.740302857688407,5.17489555150692e-11,0.0009999900013219275,45.367389239578124,21.143628824271133,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-530-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,530.0,498.2,2.61,,,72.0,13.55,48.8,12.37,42.85,0.00383465,-0.12234159999999998,43.3,1.84204604383958,13.550212141225423,3.9929125210900745e-11,0.0009999900030603593,63.871906683350744,18.677011080153125,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-535-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,535.0,503.0,2.61,,,72.0,13.65,48.85,12.46,42.95,0.00386295,-0.12246695,43.3,1.8428469333376183,13.650210242340606,3.965348519515963e-11,0.000999990009031397,64.92442765606565,18.534864343821056,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-540-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,540.0,507.8,2.61,,,72.0,13.67,48.9,12.55,43.04,0.00386861,-0.12259229999999999,43.3,1.7930689410993461,13.670197863809435,1.8567176532676053e-11,0.0009999944739718417,69.08754313448983,11.469076557941937,-0.3423,N,2025.7.3,6/23/2025,2.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-545-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,545.0,512.6,2.61,,,72.0,13.69,49.7,12.63,43.14,0.0038742699999999995,-0.1245979,43.3,1.8551784748647893,13.698091236815081,3.03430495965448e-11,0.04786599229689673,80.98705433416684,15.92756524394101,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-550-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,550.0,517.4,2.61,,,72.0,13.71,49.8,12.723,43.24,0.0038799299999999998,-0.12484859999999999,43.3,1.8534468468551777,13.716953315347054,2.8274365343814364e-11,0.048333916778437375,95.30101365087718,15.225993657442345,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Ningbo Victor Solar Technology Co Ltd VSMH144-555-M10,Ningbo Victor Solar Technology Co Ltd,Mono-c-Si,0,555.0,522.2,2.61,,,72.0,13.74,49.9,12.81,43.34,0.0038884199999999996,-0.1250993,43.3,1.8529818786801155,13.746007451943246,2.68122737336185e-11,0.04840034147748436,110.69929471947734,14.689736280195678,-0.3423,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM560N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,560.0,526.9,2.58,,,72.0,14.13,50.7,13.37,41.9,0.00674001,-0.129285,45.82,1.7790167442643114,14.142378385998926,5.860356931209693e-12,0.24135139664770386,275.50403135049055,-0.9386332107444223,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM565N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,565.0,531.7,2.58,,,72.0,14.19,50.9,13.42,42.1,0.0067686299999999994,-0.129795,45.82,1.7871631761697655,14.20293381655657,5.988117242118054e-12,0.23831650886949665,261.462750135255,-0.7949797926570955,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM570N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,570.0,536.6,2.58,,,72.0,14.25,51.1,13.48,42.3,0.00679725,-0.130305,45.82,1.7947015701256752,14.262615592378156,6.064135168483789e-12,0.23531903434528958,265.80569090941015,-0.7272135754156916,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM575N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,575.0,541.4,2.58,,,72.0,14.31,51.3,13.56,42.4,0.00682587,-0.13081500000000001,45.82,1.7989660586467418,14.320798511564929,5.841950951374451e-12,0.24080465217380376,319.1101447908972,-1.073317659502123,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM580N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,580.0,546.2,2.58,,,72.0,14.37,51.5,13.62,42.6,0.0068544899999999995,-0.131325,45.82,1.8065043922251545,14.380509427788162,5.916383982386879e-12,0.23782695331065679,325.19117275024746,-1.0050173401261338,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM585N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,585.0,551.1,2.58,,,72.0,14.43,51.7,13.67,42.8,0.0068831100000000004,-0.131835,45.82,1.8146462992725503,14.441080144855649,6.04314041189967e-12,0.23486225388694007,305.8680510806136,-0.8638960913809325,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM590N-144BDM10,Nuuko Solar GmbH,Mono-c-Si,1,590.0,555.9,2.58,,,72.0,14.49,51.9,13.75,42.9,0.00691173,-0.13234500000000002,45.82,1.818923365991087,14.49922402073397,5.825382977588097e-12,0.24027054876373852,377.4406387985481,-1.203944296373742,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Nuuko Solar GmbH NKM690N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,690.0,650.0,3.11,,,66.0,18.26,48.08,17.18,40.17,0.008454380000000001,-0.12308480000000001,46.01,1.6861048979875817,18.28211716009486,7.389447197007733e-12,0.14999737697466997,123.83832712704417,-1.4775129232802795,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM695N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,695.0,654.9,3.11,,,66.0,18.33,48.24,17.25,40.29,0.00848679,-0.12349440000000002,46.01,1.6912458617363868,18.35200522203142,7.361515101460998e-12,0.1508368763627714,125.64471938018521,-1.5402920899061003,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM700N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,700.0,659.7,3.11,,,66.0,18.4,48.4,17.33,40.41,0.0085192,-0.123904,46.01,1.695931148677148,18.42114710503648,7.282822591992826e-12,0.15169331956454518,131.98766723382312,-1.6616712517582104,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM705N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,705.0,664.5,3.11,,,66.0,18.46,48.56,17.4,40.52,0.008546980000000001,-0.12431360000000001,46.01,1.7004414629601794,18.48037402657583,7.1802803241487455e-12,0.15327790159392288,138.87829471631636,-1.8060382117589397,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM710N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,710.0,669.4,3.11,,,66.0,18.53,48.73,17.47,40.64,0.008579390000000001,-0.12474879999999999,46.01,1.7057654643529478,18.550292898473618,7.134284209953104e-12,0.1546691575140705,141.23263349389805,-1.8896348535055802,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM715N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,715.0,674.2,3.11,,,66.0,18.6,48.88,17.54,40.76,0.008611800000000001,-0.12513280000000002,46.01,1.710730784456306,18.620098517593412,7.129178156261941e-12,0.15490121857509537,143.35199877285197,-1.926796626174954,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +Nuuko Solar GmbH NKM720N-132BDG12,Nuuko Solar GmbH,Mono-c-Si,1,720.0,679.0,3.11,,,66.0,18.67,49.04,17.61,40.88,0.008644210000000001,-0.1255424,46.01,1.715876257817165,18.689954665361412,7.1041726704803255e-12,0.15570304616331096,145.67900902800056,-1.9865020310727441,-0.297,N,2025.7.3,6/23/2025,4.0,bootstrapping +ONYX SOLAR ENERGY SL ONYX G/G M06666,ONYX SOLAR ENERGY SL,Mono-c-Si,0,291.0,256.6,1.99,,,66.0,8.93,42.0,8.39,35.0,0.001786,-0.1386,49.3,1.7413920205711033,8.935674439125636,2.95327771578705e-10,0.20961461006577078,329.8755267891112,9.270880852143055,-0.46,Y,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M435B,Optivolt Labs Inc,Mono-c-Si,0,435.0,405.6,1.94,,,54.0,13.76,38.7,13.02,33.4,0.0085312,-0.102942,46.5,1.4721392263912283,13.763350867041611,5.198860071982091e-11,0.05020941945496363,206.17996908298474,13.45965531300874,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M435W,Optivolt Labs Inc,Mono-c-Si,0,435.0,405.9,1.94,,,54.0,13.76,38.7,13.02,33.4,0.0085312,-0.102942,46.3,1.4721392263912283,13.763350867041611,5.198860071982091e-11,0.05020941945496363,206.17996908298474,13.45965531300874,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M440B,Optivolt Labs Inc,Mono-c-Si,0,440.0,401.9,1.94,,,54.0,13.90608615,39.62331972,13.19136279,33.37654846,0.008343651689999999,-0.11094529521600001,48.5,1.5862868174098768,13.908892984556884,1.9626273922734114e-10,0.10608682265529044,525.5930207635521,19.83965169517284,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M440W,Optivolt Labs Inc,Mono-c-Si,0,440.0,404.3,1.94,,,54.0,13.90608615,39.62331972,13.19136279,33.37654846,0.006953043075,-0.11094529521600001,47.6,1.55682230923132,13.909547324234289,1.2221449570065644e-10,0.110949477849178,445.7657965029794,15.468006967584234,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M445B,Optivolt Labs Inc,Mono-c-Si,0,445.0,406.6,1.94,,,54.0,14.02408755,39.68768412,13.3147279,33.44292425,0.00841445253,-0.11112551553600002,48.5,1.5884754984745677,14.02636861037941,1.9691652317062693e-10,0.10442289437508166,641.997858274734,19.78632600938867,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M445W,Optivolt Labs Inc,Mono-c-Si,0,445.0,409.1,1.94,,,54.0,14.02408755,39.68768412,13.3147279,33.44292425,0.007012043775000001,-0.11112551553600002,47.6,1.5589716055892153,14.026999759672579,1.226098098328422e-10,0.10924726554185547,526.0930694290405,15.415677202290084,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M450B,Optivolt Labs Inc,Mono-c-Si,0,450.0,411.4,1.94,,,54.0,14.14208895,39.75204852,13.438093,33.50930004,0.00848525337,-0.11130573585600002,48.5,1.5906746745571219,14.143854008259325,1.9759085167205635e-10,0.10278649484340197,823.5483086946416,19.734665985564277,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Optivolt Labs Inc OPT10M450W,Optivolt Labs Inc,Mono-c-Si,0,450.0,413.8,1.94,,,54.0,14.14208895,39.75204852,13.438093,33.50930004,0.0070710444750000006,-0.11130573585600002,47.6,1.5611311891876,14.144461991568946,1.2301823276757606e-10,0.10757333131678985,641.0809537741638,15.364982758426162,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb295M60-15,Orb Energy Private Limited,Mono-c-Si,0,295.0,272.8,1.58,,,60.0,9.56,41.0,8.85,33.34,0.0053058,-0.11303700000000001,45.87,1.5636630685937327,9.585394168227396,3.79224496814151e-11,0.3281657776176628,123.54272678650484,10.010380654018311,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb300M60-15,Orb Energy Private Limited,Mono-c-Si,0,300.0,277.6,1.58,,,60.0,9.64,41.1,8.95,33.52,0.005350200000000001,-0.1133127,45.87,1.5676699737680344,9.662204773105495,3.8483755654162845e-11,0.3134830249649096,136.095801432742,10.056808634539067,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb305M60-15,Orb Energy Private Limited,Mono-c-Si,0,305.0,282.3,1.58,,,60.0,9.72,41.2,9.05,33.71,0.0053946,-0.1135884,45.87,1.571945219823124,9.739153617626819,3.92214186125856e-11,0.29783894609768985,151.14609907779968,10.142316728653498,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb310M60-15,Orb Energy Private Limited,Mono-c-Si,0,310.0,287.1,1.58,,,60.0,9.8,41.3,9.15,33.88,0.005439,-0.1138641,45.87,1.5757460998053867,9.81643398576425,3.965481104670222e-11,0.2850716435466572,169.99540949984547,10.15701767728192,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb315M60-15,Orb Energy Private Limited,Mono-c-Si,0,315.0,291.8,1.58,,,60.0,9.88,41.4,9.25,34.06,0.005483400000000001,-0.1141398,45.87,1.5798135841916034,9.893841366095684,4.02643888718141e-11,0.2713228160598537,193.67087312855364,10.21054057265246,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb320M60-15,Orb Energy Private Limited,Mono-c-Si,0,320.0,296.6,1.58,,,60.0,9.96,41.5,9.35,34.23,0.0055278,-0.1144155,45.87,1.5836571466724108,9.971476066843351,4.072742932057895e-11,0.25910390434958963,224.87450428752578,10.230557958544603,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb325M60-15,Orb Energy Private Limited,Mono-c-Si,0,325.0,301.4,1.58,,,60.0,10.04,41.6,9.45,34.4,0.005572199999999999,-0.11469120000000001,45.87,1.5875215229325674,10.049276583994295,4.1204817490405735e-11,0.24713930212758678,267.47760951740173,10.253191552001176,-0.3643,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb345M72-15,Orb Energy Private Limited,Mono-c-Si,0,345.0,316.6,1.89,,,72.0,9.42,48.9,8.64,39.94,0.00562374,-0.1464066,45.87,1.9613596730241307,9.448236371903207,1.3430926956099313e-10,0.35241231012049085,117.56907164704975,12.225865193593513,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb350M72-15,Orb Energy Private Limited,Mono-c-Si,0,350.0,321.3,1.89,,,72.0,9.5,49.0,8.74,39.839999999999996,0.0056715,-0.146706,45.87,1.9571626810003917,9.527675581436181,1.2251016313240315e-10,0.3748922730153304,128.68660712050985,11.306309721532799,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb355M72-15,Orb Energy Private Limited,Mono-c-Si,0,355.0,326.0,1.89,,,72.0,9.58,49.1,8.84,40.14,0.00571926,-0.1470054,45.87,1.964063208625496,9.60362452878574,1.285864917655006e-10,0.3437740947934658,139.40408868842067,11.657932541582209,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb360M72-15,Orb Energy Private Limited,Mono-c-Si,0,360.0,330.7,1.89,,,72.0,9.66,49.2,8.95,40.24,0.00576702,-0.1473048,45.87,1.9643657993886707,9.680479807610858,1.242934894618204e-10,0.3396761784893725,160.2198630211402,11.26243582303399,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb365M72-15,Orb Energy Private Limited,Mono-c-Si,0,365.0,335.5,1.89,,,72.0,9.74,49.3,9.05,40.34,0.00581478,-0.1476042,45.87,1.9659062783519807,9.75825454890025,1.2187735384881574e-10,0.3355166537775854,179.02016197974436,11.001618913270372,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb370M72-15,Orb Energy Private Limited,Mono-c-Si,0,370.0,340.2,1.89,,,72.0,9.82,49.4,9.15,40.44,0.005862540000000001,-0.1479036,45.87,1.9675091288535054,9.83605909622646,1.1959290499546078e-10,0.33142154985699834,202.66144969740708,10.748473800268876,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb375M72-15,Orb Energy Private Limited,Mono-c-Si,0,375.0,344.9,1.89,,,72.0,9.9,49.5,9.25,40.54,0.0059103,-0.148203,45.87,1.96917184915112,9.913893234622181,1.174311905380357e-10,0.32738985144504074,233.2904994497721,10.50269088210318,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb380M72-15,Orb Energy Private Limited,Mono-c-Si,0,380.0,349.7,1.89,,,72.0,9.98,49.6,9.35,40.64,0.00595806,-0.1485024,45.87,1.9708920695432368,9.991756738596088,1.1538401445443136e-10,0.32342052958908396,274.5435726218809,10.263976823089509,-0.3968,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb430M72-15,Orb Energy Private Limited,Mono-c-Si,0,430.0,401.0,2.12,,,72.0,10.95,50.6,10.4,41.36,0.00520125,-0.1308516,45.41,1.8485136010161243,10.953946266328796,1.4104748447297775e-11,0.3430473061878003,951.8790096600633,7.12361440558539,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb435M72-15,Orb Energy Private Limited,Mono-c-Si,0,435.0,405.8,2.12,,,72.0,11.05,50.7,10.45,41.64,0.005248750000000001,-0.1311102,45.41,1.8602853107983537,11.058234852186088,1.5951252495616947e-11,0.3188075722456491,427.79440750364347,8.140997895802089,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb440M72-15,Orb Energy Private Limited,Mono-c-Si,0,440.0,410.6,2.12,,,72.0,11.15,50.8,10.5,41.91,0.00529625,-0.1313688,45.41,1.8719009007653034,11.161878613814858,1.7971970844517698e-11,0.2958725754212511,277.7242607130252,9.13424111737414,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb445M72-15,Orb Energy Private Limited,Mono-c-Si,0,445.0,415.4,2.12,,,72.0,11.25,50.9,10.55,42.19,0.00534375,-0.1316274,45.41,1.8838086521127544,11.264842588041107,2.0304063403331577e-11,0.2720418354866892,206.19521522718895,10.160726519614643,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +Orb Energy Private Limited Orb450M72-15,Orb Energy Private Limited,Mono-c-Si,0,450.0,420.2,2.12,,,72.0,11.35,51.0,10.6,42.46,0.00539125,-0.131886,45.41,1.8693336434446752,11.368025334402121,1.5658901281551142e-11,0.2550093215081067,160.57154579549666,7.807312538938781,-0.344,N,2025.7.3,6/23/2025,4.0,first_pass +Over Easy Solar OES64-EU,Over Easy Solar,Mono-c-Si,1,64.0,60.9,0.36,,,13.0,8.04,9.75,7.74,8.24,0.0042612,-0.0231075,43.6,0.32669971514240986,8.040000620138589,8.794391639242998e-13,0.05628789371798582,729757.819312313,-4.645399658840127,-0.258,N,2025.7.3,6/23/2025,2.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV350K,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,350.0,331.3,1.69,,,60.0,10.44,43.2,9.73,36.0,0.0038627999999999996,-0.10152000000000001,46.01,1.4395445985237625,10.46340192481251,9.359849961150825e-13,0.26483705733320745,118.14835323904573,-5.048402452113424,-0.266,N,2025.7.3,6/23/2025,4.0,bootstrapping +PANASONIC CORPORATION OF NORTH AMERICA EVPV350PK,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,350.0,326.4,1.77,,,60.0,11.1,40.3,10.58,33.3,0.0041069999999999995,-0.107198,45.51,1.45322355385162,11.100005512187224,1.0039291421031215e-11,0.23555321853332026,474342.5146678758,1.2961468247549095,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV360,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,360.0,342.0,1.69,,,60.0,10.49,43.9,9.82,36.7,0.0038813000000000003,-0.10579899999999999,44.01,1.4882689751800384,10.508095486251023,1.5783220572006356e-12,0.2483413779859701,143.9641366921099,-3.3601958175264266,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV360K,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,360.0,341.0,1.69,,,60.0,10.49,43.9,9.82,36.7,0.0038813000000000003,-0.10316499999999999,46.01,1.462132658478087,10.509046107520632,9.308719016085484e-13,0.2544941859738255,140.16743360848835,-5.1482906772310715,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV360PK,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,360.0,336.0,1.77,,,60.0,11.26,40.6,10.62,33.9,0.0041662,-0.10799600000000001,45.51,1.4813675321372088,11.269913382049591,1.3869073574453409e-11,0.1951233986368534,221.62864985217763,3.929393096280869,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV370,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,370.0,351.8,1.69,,,60.0,10.55,44.1,9.9,37.4,0.0035870000000000008,-0.104076,45.45,1.4558544636204112,10.56421746917012,7.176598917418039e-13,0.19840695021303775,147.22685825319022,-7.5929458593915875,-0.258,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV370K,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,370.0,350.7,1.69,,,60.0,10.55,44.1,9.9,37.4,0.0039035000000000003,-0.10363499999999999,46.01,1.476955361090079,10.56356261518235,1.1069046599209532e-12,0.19340286540068147,150.44297889234096,-3.8142090020771042,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV370PK,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,370.0,345.6,1.77,,,60.0,11.38,41.0,10.68,34.7,0.0042106,-0.10906000000000002,45.51,1.5098563193597487,11.390619192472819,1.7910597363503882e-11,0.14451130190736686,154.86475317147287,6.04326122823496,-0.339,N,2025.7.3,6/23/2025,4.0,bootstrapping +PANASONIC CORPORATION OF NORTH AMERICA EVPV380,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,380.0,361.5,1.69,,,60.0,10.61,44.3,9.98,38.1,0.0036074,-0.104548,45.45,1.4702461593134648,10.619265466768146,8.487674874096008e-13,0.13851720578579954,158.61775669364167,-6.331068052068198,-0.258,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV390H,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,390.0,372.2,1.79,,,66.0,10.19,48.6,9.4,41.5,0.0037702999999999994,-0.11129400000000002,44.03,1.6245871978276247,10.209718834890623,9.893158326403166e-13,0.189572284265497,97.96426704117543,-1.833168008906933,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV390HK,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,390.0,371.3,1.79,,,66.0,10.19,48.6,9.4,41.5,0.0034646,-0.11323800000000002,45.0,1.6169631534247755,10.209996253969393,8.590207025570168e-13,0.1914992101326142,97.58712579038371,-4.613568890780696,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV400H,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,400.0,381.9,1.79,,,66.0,10.25,48.8,9.51,42.1,0.0037925000000000003,-0.111752,44.03,1.6346211803781996,10.262689151589031,1.0643236243193571e-12,0.13927749903202657,112.50510762917561,-1.3021630479294266,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV400HK,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,400.0,381.1,1.79,,,66.0,10.25,48.8,9.51,42.1,0.0034850000000000007,-0.113704,45.0,1.6269449808768717,10.262920924810754,9.24330558587821e-13,0.14120597265275753,112.01684408011619,-4.095537790389961,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV410H,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,410.0,391.7,1.79,,,66.0,10.35,49.0,9.61,42.7,0.0038294999999999996,-0.11221,44.03,1.6483903721718134,10.358081155115162,1.2216509887314632e-12,0.08853050875863619,113.38611286844036,-0.2395501205744106,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,410.0,390.8,1.79,,,66.0,10.35,49.0,9.61,42.7,0.003519,-0.11417000000000001,45.0,1.6406469927776397,10.35829355614454,1.0615599010435454e-12,0.0904683379577564,112.90057987626126,-3.056910646427515,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV410HK2,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,410.0,393.5,1.88,,,66.0,10.67,48.6,9.86,41.6,0.0039479,-0.11421,43.4,1.5776504564123879,10.690347307401046,4.2574222181949714e-13,0.1813652401858842,95.10679090155624,-11.263440095235522,-0.234,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV420HK2,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,420.0,403.3,1.88,,,66.0,10.74,48.8,9.96,42.2,0.0039738,-0.11467999999999999,43.4,1.588940059458521,10.753856882046701,4.718866981332005e-13,0.13304493455511304,103.11862310553595,-10.545459284281245,-0.234,N,2025.7.3,6/23/2025,4.0,first_pass +PANASONIC CORPORATION OF NORTH AMERICA EVPV430HK2,PANASONIC CORPORATION OF NORTH AMERICA,Mono-c-Si,0,430.0,413.1,1.88,,,66.0,10.81,49.0,10.05,42.8,0.0039997,-0.11514999999999999,43.4,1.6008892633964775,10.818459008993228,5.283264702231268e-13,0.08551876271043708,109.28677646342005,-9.741401177209449,-0.234,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG160M,PEIMAR,Mono-c-Si,0,160.0,141.5,1.2766400000000002,1.58,0.808,72.0,5.12,42.42,4.57,35.01,0.0027648,-0.1556814,46.9,1.9135716179468134,5.137012673838599,1.1240430493991744e-09,0.38054768530018585,114.5266402476876,14.210231550808972,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG165M,PEIMAR,Mono-c-Si,0,165.0,146.0,1.2766400000000002,1.58,0.808,72.0,5.22,42.5,4.66,35.4,0.0028187999999999998,-0.155975,46.9,1.9282738513469622,5.233491178522202,1.3008116353618869e-09,0.2907745545666975,112.50635721243118,15.403323771826445,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG170M,PEIMAR,Mono-c-Si,0,170.0,150.5,1.2766400000000002,1.58,0.808,72.0,5.35,42.7,4.78,35.6,0.002889,-0.15670900000000001,46.9,1.937477554838117,5.363272108244072,1.336387990368479e-09,0.2772436890970629,111.75721906237577,15.42356790990617,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG175M,PEIMAR,Mono-c-Si,0,175.0,155.1,1.2766400000000002,1.58,0.808,72.0,5.45,43.1,4.87,35.9,0.002943,-0.158177,46.9,1.9542961635515834,5.463894911737558,1.3414410061892728e-09,0.2830274978323659,111.01186328430526,15.283566790246127,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG180M,PEIMAR,Mono-c-Si,0,180.0,159.6,1.2766400000000002,1.58,0.808,72.0,5.59,43.3,4.99,36.1,0.0030185999999999998,-0.158911,46.9,1.9658183020120763,5.604041498935805,1.4123868579769956e-09,0.2685271768656837,106.90219746172608,15.534421980387615,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG185M,PEIMAR,Mono-c-Si,0,185.0,164.2,1.2766400000000002,1.58,0.808,72.0,5.72,43.4,5.11,36.2,0.0030888,-0.159278,46.9,1.9699521697356026,5.734007262935525,1.4399783621069752e-09,0.2596474620226947,106.02954063399838,15.497686016250396,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG190M,PEIMAR,Mono-c-Si,0,190.0,168.8,1.2766400000000002,1.58,0.808,72.0,5.86,43.5,5.23,36.3,0.0031644000000000004,-0.159645,46.9,1.9763029915405417,5.874325806885137,1.5034601916375026e-09,0.24960066927299854,102.09966544493749,15.680380247986113,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG195M,PEIMAR,Mono-c-Si,0,195.0,173.4,1.2766400000000002,1.58,0.808,72.0,6.01,43.6,5.37,36.3,0.0032454,-0.160012,46.9,1.9764915794126194,6.025553646223303,1.4713743697395375e-09,0.2632579413960878,101.72408377260064,15.233104117255522,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG200M,PEIMAR,Mono-c-Si,0,200.0,178.0,1.2766400000000002,1.58,0.808,72.0,5.95,45.7,5.54,36.12,0.003213,-0.167719,46.9,1.957812602304202,5.95914007694345,4.270822304138361e-10,0.7158490077027058,466.0029859729094,4.142643245474759,-0.484,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG205P,PEIMAR,Multi-c-Si,0,205.0,182.3,1.6268799999999999,1.64,0.992,60.0,7.84,35.1,7.0,29.3,0.0057231999999999995,-0.12671100000000002,46.9,1.584421834971646,7.859331036247245,1.7447794353641577e-09,0.1521106983424338,61.69084684856957,16.041961407412145,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG210P,PEIMAR,Multi-c-Si,0,210.0,186.9,1.6268799999999999,1.64,0.992,60.0,8.01,35.2,7.14,29.4,0.0058473,-0.12707200000000002,46.9,1.591171126069784,8.029817239411404,1.8351381920547153e-09,0.14590995505601742,58.97586606666385,16.32397675778964,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG215P,PEIMAR,Multi-c-Si,0,215.0,191.5,1.6268799999999999,1.64,0.992,60.0,8.16,35.4,7.29,29.5,0.0059568,-0.127794,46.9,1.5956492427194262,8.18106561972351,1.760155240970974e-09,0.15587932942268898,60.38158261353579,15.74263191898927,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG220M,PEIMAR,Mono-c-Si,0,220.0,197.6,1.6268799999999999,1.64,0.992,60.0,7.98,36.29,7.46,29.5,0.0026547066000000004,-0.118682816,45.2,1.5181416652178479,7.989192468767831,3.263103088085172e-10,0.3097527437040337,268.89699779991753,12.00736970840928,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG220P,PEIMAR,Multi-c-Si,0,220.0,196.0,1.6268799999999999,1.64,0.992,60.0,8.32,35.4,7.46,29.5,0.0060736,-0.127794,46.9,1.5919946605871147,8.340368349342421,1.7131536076408722e-09,0.15416040416141177,62.97096905674228,15.29139566142992,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG225M,PEIMAR,Mono-c-Si,0,225.0,202.2,1.6268799999999999,1.64,0.992,60.0,8.13,36.41,7.6,29.6,0.0027046071000000004,-0.11907526399999999,45.2,1.5232584356769,8.13937889430422,3.3293404909406647e-10,0.3046596628622229,264.0911964447792,12.020802964423625,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG225P,PEIMAR,Multi-c-Si,0,225.0,200.6,1.6268799999999999,1.64,0.992,60.0,8.46,35.8,7.6,29.6,0.0061758,-0.129238,46.9,1.6001707670332923,8.48479763252481,1.5247860341670859e-09,0.1906341101462492,65.03704509540236,14.031873211466827,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG230M,PEIMAR,Mono-c-Si,0,230.0,206.8,1.6268799999999999,1.64,0.992,60.0,8.29,36.53,7.74,29.7,0.0027578342999999995,-0.119467712,45.2,1.5293662315196268,8.30042878429086,3.4479304004293533e-10,0.2992724824486537,237.89630163498921,12.165731700120249,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG230P,PEIMAR,Multi-c-Si,0,230.0,205.2,1.6268799999999999,1.64,0.992,60.0,8.6,36.0,7.72,29.8,0.006277999999999999,-0.12996,46.9,1.6110308880680133,8.62481163867986,1.5902610583107454e-09,0.1829988540790634,63.42951920449055,14.274100001303365,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG235M,PEIMAR,Mono-c-Si,0,235.0,211.4,1.6268799999999999,1.64,0.992,60.0,8.44,36.65,7.89,29.8,0.0028077348,-0.11986016,45.2,1.5334218258856882,8.449703050254469,3.462949869166135e-10,0.29467573124033053,256.3177008102238,12.038121483762742,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG235P,PEIMAR,Multi-c-Si,0,235.0,209.8,1.6268799999999999,1.64,0.992,60.0,8.75,36.1,7.83,30.0,0.0063875,-0.13032100000000002,46.9,1.6226711791729347,8.773924344688087,1.778180147040003e-09,0.16152455929701484,59.07539198595851,15.172229393883987,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG240M,PEIMAR,Mono-c-Si,0,240.0,216.0,1.6268799999999999,1.64,0.992,60.0,8.59,36.78,8.03,29.9,0.0028576353,-0.120285312,45.2,1.538715580704675,8.599913074777401,3.516503736620963e-10,0.29139195990919975,252.50060640680283,12.017684785428028,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG240P,PEIMAR,Multi-c-Si,0,240.0,214.4,1.6268799999999999,1.64,0.992,60.0,8.9,36.2,7.95,30.2,0.006497,-0.13068200000000002,46.9,1.6329884867052529,8.922238392150069,1.952872499697838e-09,0.14109127722590828,56.46597498798102,15.905856112255071,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG245M,PEIMAR,Mono-c-Si,0,245.0,220.6,1.6268799999999999,1.64,0.992,60.0,8.71,37.02,8.14,30.1,0.0028975557000000002,-0.12107020800000001,45.2,1.5491231199294604,8.720235137805838,3.584664589243869e-10,0.28851883640797105,245.52668175933164,12.066844700627488,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG245P,PEIMAR,Multi-c-Si,0,245.0,219.0,1.6268799999999999,1.64,0.992,60.0,9.06,36.4,8.09,30.3,0.0066137999999999995,-0.131404,46.9,1.640106614301625,9.084349431744005,1.937080264424992e-09,0.14911651702043394,55.483667784372535,15.659766783292083,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG250M,PEIMAR,Mono-c-Si,0,250.0,225.3,1.6268799999999999,1.64,0.992,60.0,8.86,37.15,8.28,30.2,0.0029474562,-0.12149536,45.2,1.5544129875246344,8.87044622499962,3.637978455526998e-10,0.28544007167891106,242.0969675892204,12.046007940511803,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG250P,PEIMAR,Multi-c-Si,0,250.0,223.6,1.6268799999999999,1.64,0.992,60.0,9.21,36.5,8.22,30.4,0.006723300000000001,-0.131765,46.9,1.6456846007119588,9.234509132945453,1.99653963253373e-09,0.14449689609914992,54.298801634335945,15.792514218540076,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG255M,PEIMAR,Mono-c-Si,0,255.0,229.9,1.6268799999999999,1.64,0.992,60.0,8.92,37.64,8.33,30.6,0.0029674163999999998,-0.123097856,45.2,1.5755812092434194,8.931066037373952,3.6965551265733824e-10,0.2869561691920244,231.3067714511412,12.132168055375255,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG255P,PEIMAR,Multi-c-Si,0,255.0,231.0,1.6268799999999999,1.64,0.992,60.0,8.95,37.52,8.36,30.5,0.0050174595,-0.12389104000000001,45.4,1.561342649974273,8.961223050426641,3.221150065499426e-10,0.2876710384330794,229.40787099712693,9.53303040571643,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG260M,PEIMAR,Mono-c-Si,0,260.0,234.5,1.6268799999999999,1.64,0.992,60.0,9.15,37.39,8.55,30.4,0.0030439305000000004,-0.122280256,45.2,1.56469970645009,9.160864776608486,3.7705213148556963e-10,0.27749252491525417,233.69619580412802,12.078821570766184,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG260P,PEIMAR,Multi-c-Si,0,260.0,235.7,1.63,1.64,0.992,60.0,8.98,37.81,8.4,30.98,0.0050342778000000005,-0.12484862000000001,45.4,1.57937729571904,8.989384824686852,3.541954101538418e-10,0.2548015751860006,243.8104602749348,10.344263969527821,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG265M,PEIMAR,Mono-c-Si,0,265.0,239.2,1.6268799999999999,1.64,0.992,60.0,9.3,37.52,8.69,30.5,0.0030938310000000004,-0.12270540800000002,45.2,1.569987336371577,9.311076943981966,3.82343721270308e-10,0.2747376275475331,230.6647304030792,12.057859294993527,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG265P,PEIMAR,Multi-c-Si,0,265.0,240.3,1.63,1.64,0.992,60.0,9.09,38.04,8.5,31.18,0.0050959449,-0.12560808,45.4,1.5896146965874627,9.099690193555215,3.617899475837761e-10,0.25160742843692957,236.02333493511352,10.42629706310643,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG270M,PEIMAR,Mono-c-Si,0,270.0,243.8,1.6268799999999999,1.64,0.992,60.0,9.44,37.64,8.82,30.6,0.0031404047999999997,-0.123097856,45.2,1.5751595417493114,9.451310002901181,3.8894249065749953e-10,0.27119283890953616,226.35368369896835,12.077831779044518,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG270P,PEIMAR,Multi-c-Si,0,270.0,245.0,1.63,1.64,0.992,60.0,9.22,38.29,8.61,31.38,0.0051688242,-0.12643358,45.4,1.6010780544266454,9.230769751168175,3.7199137390811084e-10,0.250190088679753,214.18813094256691,10.552700368870887,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG275M,PEIMAR,Mono-c-Si,0,275.0,248.5,1.6268799999999999,1.64,0.992,60.0,9.55,37.88,8.93,30.8,0.0031769985000000005,-0.12388275200000001,45.2,1.5846591056032275,9.560766926674654,3.9063044164525735e-10,0.2692025551691607,238.776108202226,12.00922531098338,-0.46817,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG275P,PEIMAR,Multi-c-Si,0,275.0,249.7,1.63,1.64,0.992,60.0,9.32,38.53,8.71,31.58,0.0052248852,-0.12722606,45.4,1.6105489335405327,9.330345595965266,3.7322062832150526e-10,0.248706244750312,224.0511303450902,10.483045209079881,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG280M,PEIMAR,Mono-c-Si,0,280.0,251.2,1.9403519999999999,1.956,0.992,72.0,8.39,43.91,7.84,35.7,0.0035360494000000004,-0.148797817,45.7,1.8530487190263203,8.399552340840652,4.224346110850486e-10,0.3514592388010472,308.6932900911547,9.80232685407867,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG280P,PEIMAR,Multi-c-Si,0,280.0,251.3,1.63,1.956,0.992,60.0,9.43,38.78,8.82,31.78,0.006883899999999999,-0.1399958,46.9,1.683558733690633,9.438107503857577,9.214743012827266e-10,0.23323200545126996,271.2768977373768,8.347933015810879,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG285M,PEIMAR,Mono-c-Si,0,285.0,255.8,1.9403519999999999,1.956,0.992,72.0,8.52,44.03,7.96,35.8,0.0035908392000000003,-0.149204461,45.7,1.8583732390816239,8.52982732590714,4.3030790843138843e-10,0.34665798057412245,300.54223568196846,9.83043376813922,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG285P,PEIMAR,Multi-c-Si,0,285.0,255.9,1.63,1.956,0.992,60.0,9.55,39.02,8.92,31.98,0.0069715,-0.14086220000000002,46.9,1.6953814622398293,9.559118467140438,9.4959546644154e-10,0.23106814214411128,242.00354651654243,8.506155453007672,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG290M,PEIMAR,Mono-c-Si,0,290.0,260.5,1.9403519999999999,1.956,0.992,72.0,8.64,44.16,8.08,35.9,0.0036414144000000005,-0.149644992,45.7,1.8627305118309267,8.649267605700897,4.3065403203247346e-10,0.34379721964801835,320.5152026946695,9.709946136263309,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG290P,PEIMAR,Multi-c-Si,0,290.0,260.6,1.63,1.956,0.992,60.0,9.64,39.28,9.01,32.2,0.0070372,-0.1418008,46.9,1.706267665258172,9.648736669356493,9.539807327474436e-10,0.22963222534149189,253.37519429036686,8.461919474281283,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG295M,PEIMAR,Mono-c-Si,0,295.0,265.1,1.9403519999999999,1.956,0.992,72.0,8.77,44.28,8.19,36.0,0.0036962042000000003,-0.15005163600000002,45.7,1.8692676629022453,8.780445929190417,4.446354973515395e-10,0.33910737128537666,284.7015413991155,9.866014363764021,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG295P,PEIMAR,Multi-c-Si,0,295.0,263.7,1.9403519999999999,1.956,0.992,72.0,9.15,43.3,8.17,36.1,0.0066795000000000005,-0.15631299999999998,46.9,1.9529827464283445,9.17346278202566,2.0003204441945124e-09,0.16738250284870218,65.27572283826318,15.871683087064829,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM295M (BF),PEIMAR,Mono-c-Si,0,295.0,272.5,1.63,,,60.0,9.5,40.21,8.98,32.95,0.005149,-0.11327157,45.5,1.537073949894772,9.505728027799023,4.101500395191853e-11,0.28839885862227344,478.31284167712835,8.323405134593576,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM295M (FB),PEIMAR,Mono-c-Si,0,295.0,271.6,1.63,,,60.0,9.5,40.21,8.98,32.95,0.0054150000000000005,-0.11367367,46.2,1.545895816076701,9.505485249314633,4.76324081111544e-11,0.2862843066688492,495.8208589759684,9.21315181954082,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG300M,PEIMAR,Mono-c-Si,0,300.0,271.2,1.63,1.956,0.992,60.0,9.72,40.33,9.08,33.05,0.004096591200000001,-0.136666271,45.7,1.7101121945745656,9.730397303221654,5.471616088082889e-10,0.24471111467419776,228.77013026879072,10.799479469023744,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG300P,PEIMAR,Multi-c-Si,0,300.0,268.3,1.9403519999999999,1.956,0.992,72.0,9.27,43.4,8.28,36.2,0.006767099999999999,-0.15667399999999998,46.9,1.9576317818209548,9.293317838960496,2.0304956103358217e-09,0.16333432355731067,64.93351874452586,15.889297475175331,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM300M (BF),PEIMAR,Mono-c-Si,0,300.0,277.3,1.63,,,60.0,9.59,40.45,9.07,33.15,0.00519778,-0.11394765000000001,45.5,1.5459211851712635,9.595336165124351,4.120100080576604e-11,0.2869940535532078,515.777344343868,8.278283748687661,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM300M (FB),PEIMAR,Mono-c-Si,0,300.0,276.3,1.63,,,60.0,9.59,40.45,9.07,33.15,0.0054663,-0.11435215000000001,46.2,1.5547927577979905,9.595094535098871,4.784908254834324e-11,0.2848887781283494,536.2772956025193,9.167811806421314,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG305M,PEIMAR,Mono-c-Si,0,305.0,275.8,1.63,1.956,0.992,60.0,9.83,40.57,9.18,33.25,0.0041429518,-0.137479559,45.7,1.7206726641267345,9.84071710069734,5.560660133960886e-10,0.2429434771176653,222.83402272757718,10.844406689028505,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG305P,PEIMAR,Multi-c-Si,0,305.0,276.4,1.9403519999999999,1.956,0.992,72.0,9.02,44.53,8.43,36.2,0.0050567022,-0.14703806,45.4,1.852558686245452,9.030881395612978,3.2276425639053824e-10,0.33860375756582295,280.6814798317919,9.479950616239726,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM305M (BF),PEIMAR,Mono-c-Si,0,305.0,282.0,1.63,,,60.0,9.69,40.7,9.16,33.35,0.00525198,-0.11465190000000001,45.5,1.5557342994359746,9.695807285087934,4.17881121087849e-11,0.28638480306143166,477.8599290008606,8.313326089642544,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM305M (FB),PEIMAR,Mono-c-Si,0,305.0,281.0,1.63,,,60.0,9.69,40.7,9.16,33.35,0.0055233,-0.1150589,46.2,1.5646630099995935,9.695559769533348,4.853037552384114e-11,0.2842867895031906,495.47721170124527,9.20301519852496,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG310M,PEIMAR,Mono-c-Si,0,310.0,280.5,1.63,1.956,0.992,60.0,9.92,40.81,9.27,33.45,0.0041808832,-0.138292847,45.7,1.730341051117932,9.930338859991215,5.576881538881153e-10,0.2418329137955228,232.03553342934944,10.78651296842987,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG310P,PEIMAR,Multi-c-Si,0,310.0,281.0,1.9403519999999999,1.956,0.992,72.0,9.14,44.65,8.54,36.3,0.0051239754,-0.1474343,45.4,1.8578725867580448,9.151217122669522,3.2832070324809055e-10,0.3346955987085895,272.71861398124537,9.514968712410521,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM310M (BF),PEIMAR,Mono-c-Si,0,310.0,286.8,1.63,,,60.0,9.79,40.94,9.25,33.55,0.005306179999999999,-0.11532798,45.5,1.5653630407978354,9.796274235989088,4.2516552723836065e-11,0.28469223306081853,444.2193533590612,8.376800823884663,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM310M (FB),PEIMAR,Mono-c-Si,0,310.0,285.8,1.63,,,60.0,9.79,40.94,9.25,33.55,0.0055803,-0.11573738,46.2,1.5743485844015919,9.796021565046535,4.9375466899285787e-11,0.2826010264614475,459.4593129816133,9.266827895165116,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG315M,PEIMAR,Mono-c-Si,0,315.0,285.2,1.63,1.956,0.992,60.0,9.99,41.18,9.34,33.75,0.004210385400000001,-0.139546666,45.7,1.7454605998788026,10.000066152870053,5.576596305854585e-10,0.2427974384447472,240.96065759032922,10.721273939901602,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG315P,PEIMAR,Multi-c-Si,0,315.0,285.7,1.9403519999999999,1.956,0.992,72.0,9.26,44.77,8.65,36.4,0.0051912486,-0.14783054,45.4,1.863181986233522,9.27155222391847,3.338905130595119e-10,0.3308888479128542,265.2330081363361,9.549318586209909,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM315M (BF),PEIMAR,Mono-c-Si,0,315.0,291.5,1.63,,,60.0,9.89,41.18,9.34,33.75,0.00536038,-0.11600406,45.5,1.5749893885545725,9.896739820368353,4.324793301858262e-11,0.28303327550033736,415.32252047877324,8.43920637672327,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM315M (FB),PEIMAR,Mono-c-Si,0,315.0,290.5,1.63,,,60.0,9.89,41.18,9.34,33.75,0.0056373000000000005,-0.11641586,46.2,1.584031738069546,9.896481990110251,5.0223952663633547e-11,0.280948752085408,428.66206423244984,9.329565053992603,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG320M,PEIMAR,Mono-c-Si,0,320.0,288.2,1.9403519999999999,1.956,0.992,72.0,9.38,44.9,8.77,36.5,0.003953294800000001,-0.15215263,45.7,1.8941073173547356,9.390250021532447,4.683630780165333e-10,0.32217526333817575,294.8290886617936,9.726403492048815,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG320P,PEIMAR,Multi-c-Si,0,320.0,290.3,1.94,1.956,0.992,72.0,9.14,45.75,8.54,37.5,0.0051239754,-0.1510665,45.4,1.912628011832485,9.150279958633197,3.672211872763178e-10,0.30077197175556236,267.41898817866286,10.513279627969702,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM320M (BF),PEIMAR,Mono-c-Si,0,320.0,296.3,1.63,,,60.0,9.98,41.42,9.43,33.95,0.00540916,-0.11668014,45.5,1.5838394513897005,9.986347784930821,4.343178127609444e-11,0.28173215272278657,442.9398158100234,8.394859959078078,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM320M (FB),PEIMAR,Mono-c-Si,0,320.0,295.3,1.63,,,60.0,9.98,41.42,9.43,33.95,0.0056886,-0.11709434,46.2,1.5929315402731143,9.98609112188564,5.0438154576759123e-11,0.2796562562232917,458.20287290321187,9.285004568985768,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG325M,PEIMAR,Mono-c-Si,0,325.0,292.9,1.9403519999999999,1.956,0.992,72.0,9.48,45.14,8.86,36.7,0.0039954408000000005,-0.152965918,45.7,1.9047860395859588,9.490662327364856,4.764010113812689e-10,0.31978343733777803,284.32324501187804,9.784713777220531,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG325P,PEIMAR,Multi-c-Si,0,325.0,295.0,1.94,1.956,0.992,72.0,9.24,45.99,8.63,37.7,0.005180036400000001,-0.15185898,45.4,1.9231715909231928,9.250654351577413,3.73420779812581e-10,0.298568818734043,258.93421802579803,10.567132864787121,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM325M (BF),PEIMAR,Mono-c-Si,0,325.0,301.0,1.63,,,60.0,10.08,41.67,9.52,34.15,0.00546336,-0.11738439,45.5,1.5936449534296293,10.08681976796336,4.4020511644198423e-11,0.28119882948974134,415.62767317775644,8.427350444402638,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM325M (FB),PEIMAR,Mono-c-Si,0,325.0,300.0,1.63,,,60.0,10.08,41.67,9.52,34.15,0.0057456,-0.11780109000000001,46.2,1.6027941054075818,10.086557203324507,5.112131023299603e-11,0.27912966366665953,429.08950263260016,9.317642589090136,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG330M,PEIMAR,Mono-c-Si,0,330.0,297.5,1.9403519999999999,1.956,0.992,72.0,9.6,45.26,8.97,36.8,0.004046016,-0.153372562,45.7,1.9101713441223536,9.610984532358474,4.842177425744234e-10,0.3162778827605336,276.41305490133743,9.818383686754645,-0.46757,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG330P,PEIMAR,Multi-c-Si,0,330.0,299.7,1.94,1.956,0.992,72.0,9.32,46.24,8.71,37.9,0.0052248852,-0.15268448,45.4,1.9328470776535613,9.330343239796907,3.733175897813999e-10,0.298375796564102,268.85799818839007,10.485371470031707,-0.44277,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM330M (BF),PEIMAR,Mono-c-Si,0,330.0,305.8,1.63,,,60.0,10.18,41.91,9.61,34.35,0.0055175599999999995,-0.11806047,45.5,1.6032664673322568,10.187284392221745,4.4754615769511334e-11,0.2796211740209902,390.77295752896896,8.487726485988334,-0.3722,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG335M,PEIMAR,Mono-c-Si,0,335.0,304.6,1.940352,,,72.0,9.335,46.848,8.724,38.4,0.004974808200000001,-0.1594799616,45.8,1.9329994225854843,9.345991957176382,2.7333237474942617e-10,0.30767503999296714,261.2952994908549,4.504257892543162,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG340M,PEIMAR,Mono-c-Si,0,340.0,309.3,1.940352,,,72.0,9.449,46.97,8.831,38.5,0.005035561080000001,-0.159895274,45.8,1.9379785031625818,9.460088735412143,2.7649811438810116e-10,0.30476206052864047,259.69570454166535,4.498822875800415,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF345M,PEIMAR,Mono-c-Si,0,345.0,322.2,1.75,,,60.0,10.85,40.5,10.24,33.7,0.0032549999999999996,-0.1078515,43.1,1.5295692434003634,10.857888473218106,3.3934674599912154e-11,0.20324554162559014,279.54891797192516,12.01674853963369,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG345M,PEIMAR,Mono-c-Si,0,345.0,314.0,1.940352,,,72.0,9.563,47.092,8.938,38.6,0.00509631396,-0.1603105864,45.8,1.9429586190962842,9.574185511952066,2.796639842920698e-10,0.30191838810577987,258.12370498572085,4.493518689182583,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF350M,PEIMAR,Mono-c-Si,0,350.0,327.0,1.75,,,60.0,10.94,40.7,10.33,33.9,0.0032819999999999998,-0.1083841,43.1,1.5375344036489573,10.94750773002519,3.4476161972873653e-11,0.19886741616857992,289.78260494457476,12.08319669504125,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG350M,PEIMAR,Mono-c-Si,0,350.0,318.7,1.940352,,,72.0,9.677,47.214,9.044,38.7,0.005157066839999999,-0.1607258988,45.8,1.94805616469956,9.688363438061808,2.832026863151908e-10,0.29912606774836925,254.73304618479807,4.499834677855507,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF355M,PEIMAR,Mono-c-Si,0,355.0,331.8,1.75,,,60.0,11.03,40.92,10.42,34.1,0.003309,-0.10896995999999999,43.1,1.5458692491960506,11.037180390053974,3.4792031852001104e-11,0.19650397819272775,301.8552817768393,12.089505122334703,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG355M,PEIMAR,Mono-c-Si,0,355.0,323.4,1.940352,,,72.0,9.79,47.336,9.149,38.8,0.005217286799999999,-0.1611412112,45.8,1.9531601205127327,9.801545495319367,2.8673672894897025e-10,0.296428196933306,251.3562401585921,4.506748437252238,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL355M,PEIMAR,Mono-c-Si,0,355.0,332.5,1.81,,,60.0,11.03,40.95,10.42,34.1,0.00482011,-0.10978695000000001,43.3,1.5334351021356367,11.03759964465009,2.7518377830166152e-11,0.20215687852682643,293.4071919531494,9.071015578662522,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM355M,PEIMAR,Mono-c-Si,0,355.0,328.7,1.94,,,72.0,9.54,48.19,9.01,39.5,0.0050466600000000006,-0.13049851999999998,45.9,1.806553637577186,9.547331964511036,2.4559187793734126e-11,0.35154295853868633,457.41080449389773,8.123085392285237,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF360M,PEIMAR,Mono-c-Si,0,360.0,336.6,1.75,,,60.0,11.12,41.2,10.5,34.3,0.0033359999999999996,-0.1097156,43.1,1.5560373718114633,11.127672891147546,3.4816029320671044e-11,0.1998591678495713,289.6475311368015,12.024212345491291,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG360M,PEIMAR,Mono-c-Si,0,360.0,328.1,1.94,,,72.0,9.71,48.44,9.07,39.7,0.0051746532000000005,-0.164899448,45.8,1.9990754103843107,9.721812677234126,2.854909801116744e-10,0.30641101312475927,251.8693289745933,4.5408326362779,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL360M,PEIMAR,Mono-c-Si,0,360.0,337.3,1.81,,,60.0,11.11,41.2,10.5,34.3,0.0048550699999999995,-0.1104572,43.3,1.542293134023121,11.117362658666805,2.749157821227473e-11,0.2028604685145565,306.10948947418086,8.99672700563504,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM360M,PEIMAR,Mono-c-Si,0,360.0,333.4,1.94,,,72.0,9.62,48.44,9.09,39.7,0.00508898,-0.13117552,45.9,1.815385823423907,9.626988032052854,2.4583922154497767e-11,0.35106925257007005,483.2957617492478,8.056674124542786,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF365M,PEIMAR,Mono-c-Si,0,365.0,341.4,1.75,,,60.0,11.21,42.09,10.58,34.5,0.003363,-0.11208567000000001,43.1,1.5773947473818584,11.219314644164937,2.8600574350552063e-11,0.26148967999672823,314.69794345198454,10.186493184024851,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG365M,PEIMAR,Mono-c-Si,0,365.0,332.8,1.94,,,72.0,9.79,48.68,9.15,39.9,0.005217286799999999,-0.165716456,45.8,2.0084495102596733,9.801469952145135,2.862007118726036e-10,0.30507085288629704,260.3885235948341,4.4905717350912155,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL365M,PEIMAR,Mono-c-Si,0,365.0,342.1,1.81,,,60.0,11.21,41.4,10.58,34.5,0.00489877,-0.11099339999999999,43.3,1.5515834588155193,11.218354088911097,2.8565069465124458e-11,0.19826216061931634,266.039644586872,9.262187004695534,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM365M,PEIMAR,Mono-c-Si,0,365.0,338.2,1.94,,,72.0,9.7,48.68,9.16,39.9,0.0051313,-0.13182544,45.9,1.824990072006868,9.707559097830199,2.4992175737921434e-11,0.3494626206250319,448.43810130772306,8.130973235115071,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SG370M,PEIMAR,Mono-c-Si,0,370.0,337.5,1.94,,,72.0,9.81,48.93,9.23,40.1,0.0052279452,-0.166567506,45.8,2.011421016877427,9.816506081686926,2.6459326679707985e-10,0.3075477041278875,463.72664065232783,3.790204223836213,-0.43052,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL370M,PEIMAR,Mono-c-Si,0,370.0,346.9,1.81,,,60.0,11.3,41.6,10.67,34.7,0.004938100000000001,-0.1115296,43.3,1.5594839198440609,11.30797294569719,2.9008047719224388e-11,0.19408079194508243,275.0693478741681,9.325809188716676,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM370M,PEIMAR,Mono-c-Si,0,370.0,342.9,1.94,,,72.0,9.78,48.92,9.24,40.1,0.00517362,-0.13247536,45.9,1.833642383126909,9.787207679930315,2.5086102874801755e-11,0.3479176108922778,472.08451279607704,8.089902993345532,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL375M,PEIMAR,Mono-c-Si,0,375.0,351.7,1.81,,,60.0,11.38,41.8,10.75,34.9,0.0049730600000000005,-0.1120658,43.3,1.56742499590587,11.387632743734633,2.944643950983963e-11,0.19013117799957752,283.4751048510297,9.39460779580301,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM375M,PEIMAR,Mono-c-Si,0,375.0,347.7,1.94,,,72.0,9.86,49.17,9.31,40.3,0.00521594,-0.13315236,45.9,1.8434251972174824,9.867786378323027,2.5425011307611434e-11,0.3474498849530675,439.9806464843954,8.138546829489945,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF380M,PEIMAR,Mono-c-Si,0,380.0,354.9,1.93,,,66.0,10.82,44.64,10.2,37.2,0.003246,-0.11887632,43.1,1.6881613962240263,10.828522515038845,3.499652865907007e-11,0.2182951105785562,277.14273488928455,12.326206643150746,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL380M,PEIMAR,Mono-c-Si,0,380.0,356.5,1.81,,,60.0,11.47,42.11,10.83,35.1,0.005012390000000001,-0.11289691000000002,43.3,1.5780563417125792,11.478203476788567,2.917420622317764e-11,0.196244326792696,274.38639700768414,9.244241733287536,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM380M,PEIMAR,Mono-c-Si,0,380.0,352.4,1.94,,,72.0,9.94,49.41,9.39,40.5,0.005258260000000001,-0.13380228,45.9,1.8520796744476613,9.947434560087192,2.5518935826765276e-11,0.3459457740944664,462.5291815307977,8.098105982018067,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE385M,PEIMAR,Mono-c-Si,0,385.0,361.2,1.89,,,54.0,13.08,36.7,12.23,31.5,0.00459108,-0.09611730000000002,43.3,1.3815392835891047,13.08880599876074,3.696262445662079e-11,0.06765431368038362,100.49041473722339,12.977360455890171,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF385M,PEIMAR,Mono-c-Si,0,385.0,359.7,1.93,,,66.0,10.91,44.88,10.3,37.4,0.003273,-0.11951544,43.1,1.6960063142024129,10.917556661587561,3.467676139520188e-11,0.21782088004525732,314.4809129173884,12.161376100338552,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL385M,PEIMAR,Mono-c-Si,0,385.0,361.3,1.81,,,60.0,11.55,42.26,10.91,35.3,0.005047350000000001,-0.11329906,43.3,1.5850722386474692,11.55774022426075,3.00839312694653e-11,0.18771019764969274,280.1020661003394,9.453342407315688,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM385M,PEIMAR,Mono-c-Si,0,385.0,357.2,1.94,,,72.0,10.02,49.66,9.46,40.7,0.00530058,-0.13447927999999998,45.9,1.8618590748875747,10.028013801557906,2.585769795263995e-11,0.34550150933702073,431.9953718685151,8.14582280278714,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE390M,PEIMAR,Mono-c-Si,0,390.0,366.0,1.89,,,54.0,13.41,36.8,12.53,31.14,0.00470691,-0.09637920000000001,43.3,1.375727587915508,13.424567572053759,3.151200904817357e-11,0.10688084559781863,98.38789077593768,11.304594141959766,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF390M,PEIMAR,Mono-c-Si,0,390.0,364.5,1.93,,,66.0,10.98,45.12,10.37,37.6,0.003294,-0.12015456,43.1,1.704759448673019,10.987337203465835,3.474369235481161e-11,0.2176307491058455,325.68071349765876,12.119238498513063,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM390M,PEIMAR,Mono-c-Si,0,390.0,362.0,1.94,,,72.0,10.1,49.9,9.54,40.9,0.0053429,-0.1351292,45.9,1.870515661652747,10.10766159009559,2.5951623149086363e-11,0.3440364953942281,453.5310064604824,8.105993720256194,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H395M,PEIMAR,Mono-c-Si,0,395.0,369.9,1.94,,,54.0,13.71,36.9,13.03,30.3,0.0075405,-0.112914,43.7,1.3901632744393695,13.712734814157818,4.0557929627982596e-11,0.1809966145478979,907.3610217535456,-3.3667392653332047,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE395M,PEIMAR,Mono-c-Si,0,395.0,370.8,1.89,,,54.0,13.55,36.9,12.67,31.2,0.00475605,-0.09664110000000001,43.3,1.3784043485931496,13.564548122914879,3.122063016244911e-11,0.10838310149313074,100.94711467829693,11.124128624263173,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF395M,PEIMAR,Mono-c-Si,0,395.0,369.2,1.93,,,66.0,11.07,45.36,10.45,37.8,0.003321,-0.12079367999999999,43.1,1.714224416027116,11.07773976014475,3.522405825501255e-11,0.21695885500774623,310.3112387799911,12.171797292312219,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM395M,PEIMAR,Mono-c-Si,0,395.0,366.7,1.94,,,72.0,10.18,50.14,9.61,41.1,0.0053852200000000005,-0.13577912,45.9,1.8801098373890106,10.1882314967748,2.636177691430078e-11,0.3425605106230815,423.6490827541644,8.176709275241361,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H400M,PEIMAR,Mono-c-Si,0,400.0,374.7,1.94,,,54.0,13.78,37.0,13.15,30.4,0.007579000000000001,-0.11322,43.7,1.3937649750741437,13.780002410225354,4.074922822646331e-11,0.17489109589447888,999992.1966404966,-3.378397408905335,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE400M,PEIMAR,Mono-c-Si,0,400.0,375.7,1.89,,,54.0,13.68,37.0,12.78,31.3,0.00480168,-0.096903,43.3,1.3831200196175517,13.695079487974196,3.208818893337394e-11,0.10614960044773217,96.29813313575114,11.288981057467174,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF400M,PEIMAR,Mono-c-Si,0,400.0,374.0,1.93,,,66.0,11.16,45.6,10.53,38.0,0.003348,-0.1214328,43.1,1.7236999838391804,11.168141902619128,3.5712431635143925e-11,0.21629521633472165,296.473043164881,12.225283962038702,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SM400M,PEIMAR,Mono-c-Si,0,400.0,371.5,1.94,,,72.0,10.26,50.39,9.69,41.3,0.00542754,-0.13645612,45.9,1.8889504048719972,10.267888765570753,2.6384168109119998e-11,0.3421868446422952,445.04264105428115,8.113582444388523,-0.3568,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H405M,PEIMAR,Mono-c-Si,0,405.0,379.5,1.94,,,54.0,13.85,37.1,13.27,30.5,0.007617500000000001,-0.113526,43.7,1.4000558377161074,13.850004433107241,4.29638338379028e-11,0.17617846931880832,550445.3511518863,-3.003378436799349,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE405M,PEIMAR,Mono-c-Si,0,405.0,380.5,1.89,,,54.0,13.81,37.1,12.91,31.38,0.00484731,-0.09716490000000001,43.3,1.386290243599561,13.824857679981944,3.206551113899175e-11,0.10592174391524818,98.45273899922266,11.194499890533477,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SF405M,PEIMAR,Mono-c-Si,0,405.0,378.9,1.93,,,66.0,11.25,45.84,10.61,38.2,0.003375,-0.12207192,43.1,1.7331680080826068,11.258544024530865,3.619889267715004e-11,0.21564340076707172,283.9397617898326,12.277177804397146,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H410M,PEIMAR,Mono-c-Si,0,410.0,384.3,1.94,,,54.0,13.92,37.1,13.39,30.6,0.007656,-0.113526,43.7,1.405008603897898,13.920002377790341,4.7409019561544e-11,0.1424982250476817,834100.0072197035,-2.267416849699944,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE410M,PEIMAR,Mono-c-Si,0,410.0,385.3,1.89,,,54.0,13.94,37.2,13.02,31.47,0.00489294,-0.09742680000000002,43.3,1.390770998257271,13.955497497667949,3.2799409917526766e-11,0.10463507015097619,94.11925167569377,11.317848713732905,-0.3523,N,2025.7.3,6/23/2025,4.0,bootstrapping +PEIMAR DR10H415M,PEIMAR,Mono-c-Si,0,415.0,389.1,1.94,,,54.0,14.01,37.3,13.48,30.8,0.0077055000000000005,-0.114138,43.7,1.4134674842057031,14.010002330177027,4.851072031298915e-11,0.13882012938225513,834533.6102448555,-2.1366547959917876,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE415M,PEIMAR,Mono-c-Si,0,415.0,390.1,1.89,,,54.0,14.07,37.3,13.16,31.55,0.004938570000000001,-0.0976887,43.3,1.3934115558208555,14.084787117115003,3.246923077148311e-11,0.10451305283748864,99.44458057878846,11.136920621206231,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SF415M,PEIMAR,Mono-c-Si,0,415.0,387.6,2.1,,,72.0,10.83,48.72,10.23,40.6,0.003249,-0.12974136,43.1,1.8406301393141813,10.837122838931943,3.4203076169979225e-11,0.23826904974250013,362.2788428815125,12.101065129328187,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF420M,PEIMAR,Mono-c-Si,0,420.0,392.4,2.1,,,72.0,10.91,48.96,10.3,40.8,0.003273,-0.13038048,43.1,1.8501887063944837,10.917556661587827,3.4676761392038065e-11,0.23762277822807634,343.07008680989577,12.161376107986577,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF425M,PEIMAR,Mono-c-Si,0,425.0,397.2,2.1,,,72.0,10.98,49.2,10.37,41.0,0.003294,-0.1310196,43.1,1.858913228635916,10.987337203465756,3.4743692364589445e-11,0.23731012537535268,355.1305652847873,12.119238460564377,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL425M,PEIMAR,Mono-c-Si,0,425.0,398.0,2.16,,,72.0,11.0,49.2,10.4,40.9,0.0048070000000000005,-0.13190520000000003,43.3,1.8400471330614323,11.007118445575562,2.6563660483764942e-11,0.2513759270579468,388.44649499417187,8.779668484512255,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE430M,PEIMAR,Mono-c-Si,0,430.0,403.5,2.1,,,60.0,13.34,40.8,12.47,34.5,0.004682339999999999,-0.1068552,43.3,1.524368669347937,13.354478572525387,3.0877087847715164e-11,0.12146146112419617,111.90992033307656,11.16640930322807,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF430M,PEIMAR,Mono-c-Si,0,430.0,402.0,2.1,,,72.0,11.06,49.4,10.44,41.2,0.003318,-0.13155219999999998,43.1,1.8677339195023843,11.067690777212974,3.560429448521466e-11,0.2328086647051171,334.79891508107846,12.277626783055224,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL430M,PEIMAR,Mono-c-Si,0,430.0,402.8,2.16,,,72.0,11.08,49.36,10.47,41.1,0.004841960000000001,-0.13233416,43.3,1.8480496536026338,11.08744582091739,2.752804470941746e-11,0.24295442017755361,361.53635516136654,9.033018628130144,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE435M,PEIMAR,Mono-c-Si,0,435.0,408.3,2.1,,,60.0,13.46,40.9,12.58,34.6,0.004724460000000001,-0.1071171,43.3,1.5285873861067254,13.474559040945138,3.1411505473947873e-11,0.11924108289607217,110.23974654249439,11.241103030733324,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF435M,PEIMAR,Mono-c-Si,0,435.0,406.8,2.1,,,72.0,11.13,50.5,10.51,41.4,0.0033390000000000004,-0.1344815,43.1,1.8922523105625,11.138732578572744,2.8284961716069107e-11,0.31528826033531065,401.8467591841892,10.149200252944476,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL435M,PEIMAR,Mono-c-Si,0,435.0,407.6,2.16,,,72.0,11.15,49.5,10.54,41.3,0.004872550000000001,-0.1327095,43.3,1.8548737577293897,11.157053661823452,2.834707745029668e-11,0.23304249500502458,368.3794198502157,9.235396349078508,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H440M,PEIMAR,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.0,13.05,33.7,0.0075515,-0.12546000000000002,43.7,1.5453777111616855,13.732707358977587,4.1144527691424915e-11,0.19786257969884802,1003.4330283273594,-3.2657099796228066,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE440M,PEIMAR,Mono-c-Si,0,440.0,413.1,2.1,,,60.0,13.57,41.0,12.68,34.69,0.00476307,-0.10737900000000002,43.3,1.5326184211401581,13.584758946400965,3.182222517648881e-11,0.11804474557945671,108.5353358871056,11.285801556659816,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SF440M,PEIMAR,Mono-c-Si,0,440.0,411.6,2.1,,,72.0,11.21,50.75,10.58,41.6,0.003363,-0.13514725,43.1,1.9019813933604617,11.219312346998114,2.861584229819537e-11,0.3151120897335501,379.325060084976,10.191252715997951,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL440M,PEIMAR,Mono-c-Si,0,440.0,412.4,2.16,,,72.0,11.23,49.68,10.61,41.5,0.004907510000000001,-0.13319208000000002,43.3,1.8459537945452569,11.230007709387415,2.3027313468347795e-11,0.23008321164073228,335157.3734997123,7.308250999416582,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H445M,PEIMAR,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.8,0.0075845,-0.12576600000000002,43.7,1.54887519213624,13.790002640990501,4.1246931495366104e-11,0.1914988580010622,999993.567934677,-3.289071706792257,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE445M,PEIMAR,Mono-c-Si,0,445.0,417.9,2.1,,,60.0,13.69,41.1,12.79,34.78,0.00480519,-0.10764090000000001,43.3,1.5366078086121298,13.704936018732427,3.223760691312341e-11,0.1167891943081531,107.04620194238291,11.324083348292751,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SL445M,PEIMAR,Mono-c-Si,0,445.0,417.3,2.16,,,72.0,11.31,49.88,10.68,41.7,0.004942470000000001,-0.13372828,43.3,1.8719755411043548,11.317708098936636,2.990865010429982e-11,0.22245003321010062,326.3982369656337,9.58926028941608,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H450M,PEIMAR,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.2,13.27,33.9,0.007617500000000001,-0.12607200000000002,43.7,1.551419129805903,13.927282806577212,4.079302308474387e-11,0.1930644441071485,103019.36501174951,-3.4490736509583555,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE450M,PEIMAR,Mono-c-Si,0,450.0,422.7,2.1,,,60.0,13.82,41.2,12.92,34.85,0.0048508200000000005,-0.10790280000000002,43.3,1.5395010236917281,13.834814662031292,3.209542100839825e-11,0.11735958323219609,109.48001674447833,11.196164373549497,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SL450M,PEIMAR,Mono-c-Si,0,450.0,422.1,2.16,,,72.0,11.38,50.1,10.74,41.9,0.0049730600000000005,-0.1343181,43.3,1.8811243083656373,11.38810656257161,3.045505181929107e-11,0.2202620322923673,309.20404823296064,9.69774214909964,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H455M,PEIMAR,Mono-c-Si,0,455.0,426.5,2.14,,,60.0,13.93,41.3,13.36,34.1,0.007661500000000001,-0.126378,43.7,1.5622223348330146,13.930004752941366,4.598718358549643e-11,0.18216953101355768,533926.5589175643,-2.5135538771726456,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE455M,PEIMAR,Mono-c-Si,0,455.0,427.6,2.1,,,60.0,13.94,41.3,13.02,34.94,0.00489294,-0.1081647,43.3,1.5440896017363916,13.955480931444974,3.281900264378548e-11,0.11603225443077268,104.48270757242713,11.323238529001848,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SL455M,PEIMAR,Mono-c-Si,0,455.0,426.9,2.16,,,72.0,11.45,50.36,10.81,42.1,0.00500365,-0.13501516000000002,43.3,1.8712680860222897,11.450006601011976,2.3494553813823545e-11,0.22552558071339696,391196.8723486248,7.314210288811901,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H460M,PEIMAR,Mono-c-Si,0,460.0,431.3,2.14,,,60.0,14.01,41.5,13.45,34.2,0.0077055000000000005,-0.12699000000000002,43.7,1.5696271092161522,14.010002340191628,4.6126565320917244e-11,0.16701511298866634,999935.3649429568,-2.534858986002283,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE460M,PEIMAR,Mono-c-Si,0,460.0,432.4,2.1,,,60.0,14.03,41.4,13.11,35.08,0.00492453,-0.1084266,43.3,1.5487270464844516,14.044701203124635,3.3560696137256515e-11,0.1107734525500361,105.71594258846375,11.46497690047943,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SL460M,PEIMAR,Mono-c-Si,0,460.0,431.7,2.16,,,72.0,11.52,50.64,10.88,42.3,0.005034240000000001,-0.13576584,43.3,1.8813003464771274,11.520006580698851,2.3512761619701887e-11,0.2289037177058345,400717.2698919797,7.267988008373714,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE475M,PEIMAR,Mono-c-Si,0,475.0,445.8,2.3,,,66.0,13.36,45.0,12.48,38.07,0.00468936,-0.11785500000000002,43.3,1.6822997901466532,13.374755111594187,3.1397530670893656e-11,0.13195667242954973,119.48002735417347,11.306580070735412,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE480M,PEIMAR,Mono-c-Si,0,480.0,450.6,2.3,,,66.0,13.46,45.1,12.58,38.15,0.004724460000000001,-0.11811690000000001,43.3,1.6854881049302581,13.474587295730329,3.1377278595143796e-11,0.13176490646626535,121.58220981458643,11.231272627010435,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE485M,PEIMAR,Mono-c-Si,0,485.0,455.4,2.3,,,66.0,13.57,45.2,12.69,38.24,0.00476307,-0.1183788,43.3,1.6888645755870952,13.584305681311383,3.147402850764128e-11,0.13057981523756898,123.86464253009392,11.183239833058805,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE490M,PEIMAR,Mono-c-Si,0,490.0,460.3,2.3,,,66.0,13.68,45.3,12.78,38.33,0.00480168,-0.1186407,43.3,1.6935832886634146,13.694996716622583,3.218692687542948e-11,0.12918426640553857,117.8418460457618,11.316699796912342,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE495M,PEIMAR,Mono-c-Si,0,495.0,465.1,2.3,,,66.0,13.79,45.4,12.89,38.41,0.00484029,-0.11890260000000001,43.3,1.6967360304284724,13.804809621704342,3.216910067128809e-11,0.12892978466103222,120.05315011519532,11.237073370329842,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE500M,PEIMAR,Mono-c-Si,0,500.0,469.9,2.3,,,66.0,13.89,45.5,12.99,38.5,0.004875389999999999,-0.11916450000000002,43.3,1.7001642058068942,13.904549590239878,3.226381316010045e-11,0.12787891830012876,122.08166361410474,11.196295493724076,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE505M,PEIMAR,Mono-c-Si,0,505.0,474.7,2.3,,,66.0,13.99,45.6,13.08,38.63,0.00491049,-0.11942640000000002,43.3,1.7051577313993584,14.004399603091308,3.3129466397936755e-11,0.12322088539522455,119.7158129949385,11.371563937540785,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE520M,PEIMAR,Mono-c-Si,0,520.0,488.0,2.52,,,72.0,13.37,49.2,12.49,41.63,0.004692869999999999,-0.12885480000000002,43.3,1.8394193589474475,13.384675429698936,3.147049971482267e-11,0.14354799867826404,130.77891360451156,11.320548790603786,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE525M,PEIMAR,Mono-c-Si,0,525.0,492.8,2.52,,,72.0,13.44,49.3,12.56,41.8,0.00471744,-0.1291167,43.3,1.8447473456847665,13.453798998086311,3.238075276498686e-11,0.13534378362318536,131.82264757509984,11.529331462606784,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H530M,PEIMAR,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.3,13.07,40.6,0.0075405,-0.150858,43.7,1.858183598973063,13.710003153012254,4.117608041323651e-11,0.22996538437530448,999999.871766718,-3.256973843069393,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE530M,PEIMAR,Mono-c-Si,0,530.0,497.7,2.52,,,72.0,13.58,49.4,12.69,41.79,0.00476658,-0.1293786,43.3,1.846406709434406,13.594800029325011,3.1750634009209484e-11,0.1427865243806984,131.01602478292435,11.258622795216295,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H535M,PEIMAR,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.3,13.17,40.6,0.0075845,-0.150858,43.7,1.8596856077174728,13.790003069347254,4.2313416052705527e-11,0.22256478723287038,999999.8412292764,-3.089021057411157,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE535M,PEIMAR,Mono-c-Si,0,535.0,502.5,2.52,,,72.0,13.67,49.5,12.78,41.88,0.00479817,-0.12964050000000002,43.3,1.8498354825131844,13.684564569960035,3.183553073117769e-11,0.1417214874615035,133.0168174156321,11.2211724540625,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H540M,PEIMAR,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.4,13.27,40.7,0.007617500000000001,-0.151164,43.7,1.8660492731505065,13.850006032051267,4.409111811336126e-11,0.22695659972892146,521124.511300321,-2.7998412787542706,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR SE540M,PEIMAR,Mono-c-Si,0,540.0,507.3,2.52,,,72.0,13.78,49.6,12.87,41.96,0.00483678,-0.12990240000000003,43.3,1.8544021010548315,13.795346873617824,3.244035587948782e-11,0.14112638483779377,126.71776930692319,11.322878744214416,-0.3523,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR DR10H545M,PEIMAR,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.5,13.36,40.8,0.007667,-0.15147,43.7,1.8709064120152301,13.94000287096342,4.5060964733983076e-11,0.20593919078069292,999997.5209174477,-2.6795791376416203,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE545M,PEIMAR,Mono-c-Si,0,545.0,512.1,2.52,,,72.0,13.87,49.7,12.96,42.05,0.0048683699999999995,-0.13016430000000004,43.3,1.8578323306444284,13.885110161663702,3.2524738333844534e-11,0.14008720771413488,128.58959574371633,11.285630832604484,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +PEIMAR DR10H550M,PEIMAR,Mono-c-Si,0,550.0,515.7,2.56,,,72.0,14.03,49.6,13.45,40.9,0.0077165,-0.15177600000000002,43.7,1.8752830034449084,14.030002843060743,4.5735485287454756e-11,0.20262923824575754,999996.490734499,-2.6132266665602537,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +PEIMAR SE550M,PEIMAR,Mono-c-Si,0,550.0,516.9,2.52,,,72.0,13.97,49.8,13.05,42.13,0.004903470000000001,-0.13042620000000002,43.3,1.8617140307263553,13.985427202247326,3.281703651613096e-11,0.13972814772360215,126.5298918169589,11.302655492104423,-0.3523,N,2025.7.3,6/23/2025,4.0,first_pass +Perfect Source Technology PST 176 3GP48,Perfect Source Technology,Multi-c-Si,0,176.0,156.8,1.340965,1.345,0.997,48.0,8.0,29.33,7.33,24.0,0.0072,-0.099722,46.4,1.306753578932517,8.017757910906235,1.3765388868415075e-09,0.20499669002263804,92.35173256467809,20.422421443963124,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Perfect Source Technology PST 188 3GP48,Perfect Source Technology,Multi-c-Si,0,188.0,167.8,1.340965,1.345,0.997,48.0,8.21,30.0,7.65,24.58,0.007389000000000001,-0.10200000000000001,46.4,1.3250392404855935,8.218597581403897,1.184981710109719e-09,0.20206116611927025,192.95225791198126,18.644769076569407,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Perlight Solar PLM-215P-60,Perlight Solar,Multi-c-Si,0,215.0,187.3,1.6367999999999998,1.65,0.992,60.0,7.93,36.6,7.29,29.5,0.0057096,-0.14786400000000002,47.3,1.7070177354150067,7.946161597705013,3.758150514981127e-09,0.30630521947873574,150.29468086285638,10.102923122064707,-0.534,N,2025.7.3,6/23/2025,4.0,first_pass +Perlight Solar PLM-235P-60,Perlight Solar,Multi-c-Si,0,235.0,210.9,1.6367999999999998,1.65,0.992,60.0,8.28,37.25,7.75,30.3,0.0051335999999999994,-0.152725,46.9,1.5735399370339491,8.288169533904604,4.275999742044138e-10,0.29936879357628926,303.4168227886738,-9.383098289040982,-0.441,N,2025.7.3,6/23/2025,4.0,first_pass +Perlight Solar PLM-270P-72,Perlight Solar,Multi-c-Si,0,270.0,240.1,1.950272,1.966,0.992,72.0,8.58,44.76,7.94,35.29,0.00429,-0.143232,48.5,1.821596766476917,8.603818621229584,1.7830030354249086e-10,0.5247156874647609,189.01433968892815,8.244997017414098,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Perlight Solar PLM-290P-72,Perlight Solar,Multi-c-Si,0,290.0,258.4,1.950272,1.966,0.992,72.0,8.69,45.14,8.23,35.27,0.004345,-0.14444800000000002,48.5,1.811936144104826,8.690004800906037,1.3171120709389607e-10,0.552263743210906,999999.8646938961,5.452787605558112,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M36S-95,Philadelphia Solar,Mono-c-Si,0,95.0,84.0,0.6621750000000001,1.215,0.545,36.0,5.37,22.4,5.05,18.8,0.0023950200000000003,-0.07349439999999999,48.5,0.9547045899056772,5.372333732585181,3.4275270568834676e-10,0.14564688634404865,335.13862315461637,15.579339803726677,-0.4621,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72S-185,Philadelphia Solar,Mono-c-Si,0,185.0,163.7,1.2800000000000002,1.6,0.8,72.0,5.76,43.8,5.14,36.0,0.00256896,-0.1437078,48.5,1.9009495161239003,5.783276321724451,5.272999449318278e-10,0.41242482313808015,102.05938648938755,19.199822513995006,-0.4621,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-P54-220,Philadelphia Solar,Multi-c-Si,0,220.0,195.1,1.48005,1.495,0.99,54.0,8.39,33.64,7.87,27.97,0.004253730000000001,-0.11306404000000002,47.4,1.4613483268146403,8.394756204276693,8.332443785400179e-10,0.16985319743048566,299.62311454231894,16.851839824561505,-0.4791,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-P60-270,Philadelphia Solar,Multi-c-Si,0,270.0,243.4,1.62,,,60.0,9.185,38.12,8.74,30.94,0.005575295,-0.12274639999999999,47.7,1.5499930059008071,9.185002615185853,1.9150800464930212e-10,0.2846313648267562,999999.8445494139,7.393019504035294,-0.424,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-P60-275,Philadelphia Solar,Multi-c-Si,0,275.0,248.1,1.62,,,60.0,9.23,38.2,8.82,31.2,0.00560261,-0.12300400000000003,47.7,1.5608629131961609,9.230002239411148,2.1698633162191998e-10,0.24254777079782847,999999.3248109551,8.438640300883835,-0.424,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-P60-280,Philadelphia Solar,Multi-c-Si,0,280.0,252.7,1.62,,,60.0,9.31,38.37,8.91,31.42,0.00565117,-0.12355139999999999,47.7,1.5708235099860404,9.310002096602144,2.293910886759032e-10,0.22512961435272413,999998.2294022967,8.850620722631595,-0.424,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-P60-285,Philadelphia Solar,Multi-c-Si,0,285.0,257.4,1.62,,,60.0,9.36,38.67,8.98,31.75,0.00568152,-0.12451740000000001,47.7,1.5869198384600878,9.360001947145133,2.445700747419008e-10,0.20438018703336916,981171.9237683027,9.367956615299114,-0.424,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M60(BF)-295,Philadelphia Solar,Mono-c-Si,1,295.0,270.7,1.62,,,60.0,9.83,39.6,9.3,31.74,0.00468891,-0.10707839999999999,46.1,1.516047210275765,9.833948382560264,4.433530791511675e-11,0.3585237154397496,892.5904308740799,13.351445620219831,-0.3925,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60-295,Philadelphia Solar,Mono-c-Si,0,295.0,268.7,1.62,,,60.0,9.844,39.59,9.31,31.7,0.004961376,-0.10962471,46.9,1.5468047851513183,9.847132464089402,7.518050706140779e-11,0.35480750442135367,1115.0090469995698,15.438803860316265,-0.4091,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60(BF)-300,Philadelphia Solar,Mono-c-Si,1,300.0,275.4,1.62,,,60.0,9.87,39.9,9.36,32.07,0.00470799,-0.1078896,46.1,1.5280563426713518,9.871531579043586,4.50274433476425e-11,0.3485012165134992,2245.856974599087,13.447010288601884,-0.3925,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60-300,Philadelphia Solar,Mono-c-Si,0,300.0,273.4,1.62,,,60.0,9.893,39.89,9.37,32.06,0.004986072,-0.11045541,46.9,1.5605287781753,9.894831117762115,7.817836056281853e-11,0.34072832372890755,1840.8571764955045,15.752363263369089,-0.4091,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60(BF)-305,Philadelphia Solar,Mono-c-Si,1,305.0,280.1,1.62,,,60.0,9.93,40.21,9.42,32.39,0.00473661,-0.10872783999999999,46.1,1.5414408427446338,9.931372325252505,4.6483203896305174e-11,0.3403264602756091,2462.560942745105,13.682623957693322,-0.3925,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60-305,Philadelphia Solar,Mono-c-Si,0,305.0,278.1,1.62,,,60.0,9.942,40.19,9.43,32.35,0.0050107680000000005,-0.11128610999999998,46.9,1.5724382923602178,9.942430357345916,7.890774136196635e-11,0.3355021486388999,7750.680878085064,15.78734353044447,-0.4091,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60(BF)-310,Philadelphia Solar,Mono-c-Si,1,310.0,284.8,1.62,,,60.0,9.98,40.5,9.48,32.72,0.00476046,-0.109512,46.1,1.5539651029557593,9.980243582988,4.789285714543464e-11,0.32919384950336383,13487.222787686047,13.906309788123176,-0.3925,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M60-310,Philadelphia Solar,Mono-c-Si,0,310.0,282.8,1.62,,,60.0,9.991,40.49,9.51,32.65,0.005035464,-0.11211681,46.9,1.5872925091606427,9.991003178295815,8.34173380664016e-11,0.31805798890793463,999994.122788898,16.259538170828783,-0.4091,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M60(BF)-315,Philadelphia Solar,Mono-c-Si,1,315.0,289.6,1.62,,,60.0,10.03,40.8,9.54,33.02,0.00478431,-0.11032319999999998,46.1,1.5672190615670851,10.030003205496342,4.956197716654712e-11,0.3195571648192408,999999.8676882462,14.174578209058323,-0.3925,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M60-315,Philadelphia Solar,Mono-c-Si,0,315.0,287.5,1.62,,,60.0,10.04,40.8,9.56,32.95,0.005060159999999999,-0.11297519999999998,46.9,1.6007583771668874,10.040003133047566,8.5599153015592e-11,0.31199965273893926,999991.5256743565,16.455866618739044,-0.4091,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M60-320,Philadelphia Solar,Mono-c-Si,0,320.0,292.2,1.62,,,60.0,10.09,41.1,9.63,33.24,0.005085360000000001,-0.1138059,46.9,1.6151970958734319,10.090003009722432,8.972515759161126e-11,0.298239077125884,999999.461018766,16.85189703519467,-0.4091,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-P72-335,Philadelphia Solar,Multi-c-Si,0,335.0,302.5,1.97,,,72.0,9.29,46.0,8.94,37.52,0.005481099999999999,-0.151156,47.4,1.8879432153436033,9.29020176630263,2.4333005970459993e-10,0.2542862963056644,11708.232338740165,7.196648022889104,-0.4256,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-P72-340,Philadelphia Solar,Multi-c-Si,0,340.0,307.2,1.97,,,72.0,9.38,46.2,9.03,37.72,0.0055342,-0.1518132,47.4,1.8972619741357102,9.380167158779658,2.4923145796202256e-10,0.24660933940532265,13838.362215125877,7.320453455843094,-0.4256,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M72(BF)-370,Philadelphia Solar,Mono-c-Si,1,370.0,341.9,1.97,,,72.0,9.7,48.36,9.12,40.6,0.005043999999999999,-0.13400556000000002,46.1,1.856267411957887,9.707845406735892,4.621421912598562e-11,0.22114685668333328,273.42425984416275,11.079013932008854,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72-370,Philadelphia Solar,Mono-c-Si,0,370.0,338.3,2.0,,,72.0,9.78,48.14000000000001,9.25,40.0,0.00488022,-0.14576792000000005,45.7,1.9438399947669454,9.78338074565935,1.7060187455613048e-10,0.24521442006333075,709.3693416877743,12.777864276159246,-0.4174,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-375,Philadelphia Solar,Mono-c-Si,1,375.0,346.7,1.97,,,72.0,9.78,48.63,9.18,40.85,0.0050856,-0.13475373000000002,46.1,1.8687562848217603,9.78866952461229,4.790010697588898e-11,0.21730680303504193,245.14153354413284,11.334430775125046,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72-375,Philadelphia Solar,Mono-c-Si,0,375.0,343.0,2.0,,,72.0,9.83,48.440000000000005,9.29,40.39,0.0049051699999999995,-0.14667632000000003,45.7,1.9604808122462622,9.83374861557373,1.813326396062305e-10,0.2277063552920185,597.1147623152029,13.29165966566326,-0.4174,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-380,Philadelphia Solar,Mono-c-Si,1,380.0,351.4,1.97,,,72.0,9.87,48.9,9.26,41.05,0.0051324,-0.1355019,46.1,1.878950101248656,9.879114940110284,4.819485523522948e-11,0.21976613678979626,237.9710417668537,11.309033364133652,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72-380,Philadelphia Solar,Mono-c-Si,0,380.0,347.7,2.0,,,72.0,9.88,48.74,9.34,40.7,0.0049301200000000005,-0.14758472000000003,45.7,1.97390527730661,9.883548603558584,1.8524178541481636e-10,0.22055478042842402,614.0673152013958,13.439472060740583,-0.4174,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-GG-385W,Philadelphia Solar,Mono-c-Si,1,385.0,356.3,1.96,,,54.0,13.5,36.0,12.66,30.45,0.0069795000000000005,-0.09302400000000001,45.5,1.396966531516545,13.510511137574525,8.498811232279495e-11,0.09597278661368697,123.26283507732245,21.912779501697095,-0.3743,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-385,Philadelphia Solar,Mono-c-Si,1,385.0,358.7,2.0,,,72.0,9.87,49.58,9.42,40.88,0.00478695,-0.13257692000000001,43.6,1.8874477485774928,9.870003008705197,3.8560922787128117e-11,0.3048179525591016,999999.9121919445,13.28525271006792,-0.3757,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M72-385,Philadelphia Solar,Mono-c-Si,0,385.0,352.4,2.0,,,72.0,9.925,49.04,9.4,40.96,0.004952575,-0.14849312,45.7,1.9843837813845282,9.927550678573352,1.8265319283534025e-10,0.22011423981877007,856.4912893006386,13.261623325532904,-0.4174,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HC)-390W,Philadelphia Solar,Mono-c-Si,0,390.0,362.5,1.95,,,54.0,13.55,36.25,12.72,30.69,0.0087262,-0.10273249999999999,46.3,1.3838886512496722,13.560528518244533,5.583568017955085e-11,0.09779915143581473,125.8656234902179,7.176408379788966,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-GG-390W,Philadelphia Solar,Mono-c-Si,1,390.0,361.1,1.96,,,54.0,13.55,36.23,12.72,30.71,0.0070053500000000005,-0.09361831999999999,45.5,1.3034172261556294,13.56329490413854,1.1221301326565078e-11,0.1086866956036389,110.77212085828724,3.4312174896775933,-0.3743,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-390,Philadelphia Solar,Mono-c-Si,1,390.0,363.5,2.0,,,72.0,9.92,49.88,9.47,41.19,0.0048112,-0.13337912000000002,43.6,1.900313180554279,9.920002945823635,3.953808103126213e-11,0.29694316225359235,999999.9075279584,13.468169457358727,-0.3757,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M72-390,Philadelphia Solar,Mono-c-Si,0,390.0,357.2,2.0,,,72.0,9.975000000000001,49.339999999999996,9.450000000000001,41.27,0.004977525000000001,-0.14940151999999998,45.7,1.997798986295291,9.9773925313534,1.865280672830966e-10,0.21309178663073797,888.4275926739255,13.40679375517996,-0.4174,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HC)-395W,Philadelphia Solar,Mono-c-Si,0,395.0,367.3,1.95,,,54.0,13.6,36.52,12.78,30.96,0.008758400000000001,-0.10349768,46.3,1.3944453944763824,13.60963884174363,5.636563203073637e-11,0.09456532256069916,133.4276908302378,7.222868282970997,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-395W,Philadelphia Solar,Mono-c-Si,1,395.0,371.7,1.93,,,54.0,13.69,36.78,13.04,30.3,0.0064343,-0.09378900000000001,43.6,1.3273868910488578,13.692608237272772,1.2635173940026697e-11,0.18191486034440194,954.8266680474202,5.737284210443168,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-GG-395W,Philadelphia Solar,Mono-c-Si,1,395.0,365.8,1.96,,,54.0,13.6,36.58,12.78,30.96,0.0070312000000000005,-0.09452272,45.5,1.4184611786374077,13.60926132133091,8.42570798987845e-11,0.09532031259538228,139.97530180482866,21.745647735121246,-0.3743,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-395,Philadelphia Solar,Mono-c-Si,1,395.0,368.2,2.0,,,72.0,9.97,50.18,9.52,41.5,0.004835450000000001,-0.13418132000000002,43.6,1.9131790582780306,9.970002882892672,4.052833126991113e-11,0.28914239139847514,999999.9026168381,13.648957107772652,-0.3757,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M72-395,Philadelphia Solar,Mono-c-Si,0,395.0,361.9,2.0,,,72.0,10.025000000000002,49.63999999999999,9.505,41.57,0.005002475000000001,-0.15030991999999999,45.7,2.0103973214459483,10.02697332887117,1.8866173193552904e-10,0.20748575711444572,1054.0792751211166,13.46206534442218,-0.4174,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HC)-400W,Philadelphia Solar,Mono-c-Si,0,400.0,372.1,1.95,,,54.0,13.65,36.74,12.83,31.23,0.0087906,-0.10412115999999999,46.3,1.4046452038321422,13.65887248818777,5.850515124398802e-11,0.08732647708802949,134.34860625539017,7.515033984020973,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-400W,Philadelphia Solar,Mono-c-Si,1,400.0,376.5,1.93,,,54.0,13.74,37.08,13.08,30.59,0.0064578,-0.09455399999999999,43.6,1.339491148343632,13.743358095132036,1.3010174317910424e-11,0.1789693953956059,732.2721502895592,5.9613139833370115,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-GG-400W,Philadelphia Solar,Mono-c-Si,1,400.0,370.6,1.96,,,54.0,13.65,36.81,12.83,31.23,0.007057050000000001,-0.09511704000000001,45.5,1.4289822435073085,13.658594361672723,8.705250845521177e-11,0.08883284545145355,141.08882113381281,22.030634890530315,-0.3743,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-400,Philadelphia Solar,Mono-c-Si,1,400.0,373.0,2.0,,,72.0,10.03,50.52,9.57,41.8,0.0048645500000000005,-0.13509048000000004,43.6,1.9258558480685088,10.030004264111728,4.061355794875734e-11,0.2965652166648452,697601.2731153772,13.613175886277903,-0.3757,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72-400,Philadelphia Solar,Mono-c-Si,0,400.0,371.8,2.0,,,72.0,10.3,50.0,9.67,41.38,0.0050779,-0.13755,45.0,1.900808214248394,10.311593606681491,3.811204987130259e-11,0.28760655413324765,255.51561524291384,9.666127394482197,-0.3647,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HC)-405W,Philadelphia Solar,Mono-c-Si,0,405.0,376.9,1.95,,,54.0,13.7,36.94,12.86,31.49,0.008822799999999999,-0.10468796,46.3,1.4153727270465883,13.708778332989992,6.204716017363472e-11,0.07923927125330578,123.66562397280158,8.002549970563768,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-405W,Philadelphia Solar,Mono-c-Si,1,405.0,381.3,1.93,,,54.0,13.79,37.38,13.13,30.87,0.0064813,-0.095319,43.6,1.3509137882797184,13.793207629751555,1.3216534563964103e-11,0.176927734974341,760.6341210605252,6.065500099365578,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-GG-405W,Philadelphia Solar,Mono-c-Si,1,405.0,375.4,1.96,,,54.0,13.7,36.94,12.86,31.49,0.0070829,-0.09545296,45.5,1.438508265842359,13.708038666818696,9.447920110167878e-11,0.07522318218878912,128.2000652268306,22.812009168233573,-0.3743,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72(BF)-405,Philadelphia Solar,Mono-c-Si,1,405.0,377.8,2.0,,,72.0,10.08,50.8,9.62,42.1,0.0048888000000000004,-0.13583920000000002,43.6,1.9380858920131798,10.080004223554827,4.16848964668721e-11,0.2885192618516273,688608.1263630295,13.806637117505389,-0.3757,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M72-405,Philadelphia Solar,Mono-c-Si,0,405.0,376.6,2.0,,,72.0,10.35,50.32,9.72,41.7,0.005102549999999999,-0.13843032,45.0,1.9139976188359555,10.36122040136334,3.8849228904321965e-11,0.2815203339704206,259.6819310100129,9.792276868214183,-0.3647,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HC)-410W,Philadelphia Solar,Mono-c-Si,0,410.0,381.7,1.95,,,54.0,13.75,37.25,12.92,31.75,0.008855,-0.1055665,46.3,1.3960162771346618,13.759366491796682,3.473849815653307e-11,0.08543374446281495,125.41664666047842,3.0102781195944313,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-410W,Philadelphia Solar,Mono-c-Si,1,410.0,386.1,1.93,,,54.0,13.83,37.68,13.18,31.17,0.0065001,-0.096084,43.6,1.362312163857925,13.832292739632639,1.3417487346418004e-11,0.17330485260001727,1045.389604988881,6.167571397989583,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-GG-410W,Philadelphia Solar,Mono-c-Si,1,410.0,380.1,1.96,,,54.0,13.75,37.27,12.93,31.76,0.007108750000000001,-0.09630568000000002,45.5,1.449776738776224,13.757366207948547,9.240098953992266e-11,0.07690791375512745,143.55878014130596,22.546848936145803,-0.3743,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HC)-415W,Philadelphia Solar,Mono-c-Si,0,415.0,386.5,1.95,,,54.0,13.8,37.52,12.97,32.05,0.008887200000000001,-0.10633168,46.3,1.4053200900696965,13.808745298718366,3.432989830831387e-11,0.0799847663752654,126.21521764961338,2.881202990069672,-0.3422,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M108(HCBF)-415W,Philadelphia Solar,Multi-c-Si,1,415.0,391.0,1.93,,,54.0,13.87,37.98,13.22,31.43,0.006518899999999999,-0.09684899999999999,43.6,1.3733225074543407,13.87216398486748,1.3502537636343649e-11,0.17315870092648045,1109.8566396493475,6.196765966276984,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-425W,Philadelphia Solar,Mono-c-Si,1,425.0,402.8,1.95,,,54.0,14.05,38.29,13.23,32.23,0.006884500000000001,-0.08749265,43.5,1.351605912386067,14.064240431764517,6.852190731132193e-12,0.13389117247680118,132.10073856795245,12.134000521099983,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-430W,Philadelphia Solar,Mono-c-Si,1,430.0,400.2,2.15,,,72.0,11.05,48.92,10.5,41.0,0.005381350000000001,-0.14597728000000001,44.1,1.8845096567433524,11.05000814833058,5.88168734094301e-11,0.20187799642756002,273772.44154367317,4.003365374160389,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-430W,Philadelphia Solar,Mono-c-Si,1,430.0,407.6,1.95,,,54.0,14.13,38.42,13.28,32.49,0.0069237000000000005,-0.08778970000000001,43.5,1.3603758681840565,14.144555896062508,7.498259811251692e-12,0.1205472986980351,117.02018877643302,12.925000794245635,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-435W,Philadelphia Solar,Mono-c-Si,1,435.0,405.0,2.15,,,72.0,11.1,49.2,10.55,41.26,0.0054057,-0.14681280000000002,44.1,1.9020793173949848,11.102112135907797,6.455146529472828e-11,0.1981613985458984,1041.4063138202728,4.76278139625241,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-435W,Philadelphia Solar,Mono-c-Si,1,435.0,404.8,2.15,,,72.0,11.3,48.5,10.75,40.52,0.0059438,-0.138225,45.4,1.828629797542213,11.302239397999818,3.410704968026506e-11,0.21698010585078015,1094.8814367110667,4.010456227293955,-0.3538,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-435W,Philadelphia Solar,Mono-c-Si,1,435.0,412.5,1.95,,,54.0,14.22,38.5,13.32,32.76,0.006967800000000001,-0.08797250000000001,43.5,1.3693621122688096,14.234850757599402,8.529054105676572e-12,0.10245869293563115,98.10695553671871,14.083606182025223,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-440W,Philadelphia Solar,Mono-c-Si,0,440.0,410.2,2.15,,,72.0,11.26,49.2,10.72,41.08,0.005843940000000001,-0.1386456,45.4,1.837452682951689,11.261980855453505,2.6386764889992487e-11,0.2270001611625397,1290.3626675957207,3.0732025309099313,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-440W,Philadelphia Solar,Mono-c-Si,1,440.0,409.8,2.15,,,72.0,11.15,49.53,10.59,41.55,0.0054300500000000005,-0.14779752000000002,44.1,1.9158473567531498,11.15255038437624,6.567576657009899e-11,0.1970338403690134,861.4103385207696,4.873773367180391,-0.3758,N,2025.7.3,6/23/2025,4.0,bootstrapping +Philadelphia Solar PS-M144(HCBF)-GG-440W,Philadelphia Solar,Mono-c-Si,1,440.0,409.6,2.15,,,72.0,11.35,48.8,10.8,40.82,0.0059701,-0.13907999999999998,45.4,1.835914233943535,11.350008200033129,3.244228368675112e-11,0.21305606567658067,294902.7708362194,3.540040768999528,-0.3538,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-440W,Philadelphia Solar,Mono-c-Si,1,440.0,417.3,1.95,,,54.0,14.3,38.63,13.36,32.98,0.007007000000000001,-0.08826955000000002,43.5,1.3778653882298875,14.315134510489514,9.252563259936855e-12,0.09263157919171527,87.52391330207205,14.808541109921979,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-445W,Philadelphia Solar,Mono-c-Si,0,445.0,415.0,2.15,,,72.0,11.32,49.3,10.77,41.35,0.00587508,-0.1389274,45.4,1.8399225477999808,11.320006873607579,2.612712131338068e-11,0.20743509049228578,341623.8492166353,2.935047022677853,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-445W,Philadelphia Solar,Mono-c-Si,1,445.0,414.6,2.15,,,72.0,11.22,49.61,10.65,41.8,0.00546414,-0.14803623999999999,44.1,1.9239952651222172,11.222820762327448,7.065127319145001e-11,0.1761897511869453,700.8208659635353,5.443992248274924,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-445W,Philadelphia Solar,Mono-c-Si,1,445.0,414.4,2.15,,,72.0,11.4,49.1,10.84,41.1,0.005996400000000001,-0.139935,45.4,1.8535190005331712,11.40259633488986,3.55170932168617e-11,0.20932029073466588,919.0845947163582,4.2802230140673965,-0.3538,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-445W,Philadelphia Solar,Mono-c-Si,1,445.0,422.2,1.95,,,54.0,14.38,38.76,13.4,33.23,0.007046200000000001,-0.08856660000000001,43.5,1.386993234336706,14.394614508923565,1.0153959175930583e-11,0.08030910946472843,79.0204447637252,15.647224973314811,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-450W,Philadelphia Solar,Mono-c-Si,0,450.0,419.8,2.15,,,72.0,11.4,49.41,10.81,41.62,0.0059166,-0.13923738,45.4,1.8450544147768428,11.400005980981298,2.6706979323293414e-11,0.18826367364119348,358841.9454700872,3.0594800787794827,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-450W,Philadelphia Solar,Mono-c-Si,1,450.0,419.4,2.15,,,72.0,11.27,49.75,10.75,41.94,0.0054884899999999995,-0.148454,44.1,1.9251727835845172,11.27016965043789,6.742144692153738e-11,0.174448416466773,11588.74124017568,4.989170512391861,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-450W,Philadelphia Solar,Mono-c-Si,1,450.0,419.2,2.15,,,72.0,11.45,49.4,10.89,41.39,0.0060227,-0.14079,45.4,1.8655429377805341,11.45245465267956,3.603499697304223e-11,0.20559940965170279,959.041312687117,4.364879763103812,-0.3538,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-450W,Philadelphia Solar,Mono-c-Si,1,450.0,427.0,1.95,,,54.0,14.47,38.84,13.44,33.51,0.007090300000000002,-0.0887494,43.5,1.3962864577755418,14.482682706759695,1.1570377582623032e-11,0.06163230489056923,70.31775388241036,16.8480259460567,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-455W,Philadelphia Solar,Mono-c-Si,0,455.0,424.6,2.15,,,72.0,11.48,49.5,10.88,41.81,0.005958120000000001,-0.139491,45.4,1.8637909287648442,11.484589176212022,3.3222754200595004e-11,0.17283034788642568,432.34173784624244,4.872840796397395,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-455W,Philadelphia Solar,Mono-c-Si,1,455.0,424.1,2.15,,,72.0,11.38,49.8,10.88,41.81,0.0055420600000000006,-0.1486032,44.1,1.9248804128871229,11.380003764397069,6.609771553362651e-11,0.19083206332470595,576918.0411364501,4.738075944269051,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-455W,Philadelphia Solar,Mono-c-Si,1,455.0,424.0,2.15,,,72.0,11.5,49.7,10.94,41.65,0.0060490000000000006,-0.141645,45.4,1.8768670782481096,11.502315955820261,3.619854599310653e-11,0.2050692652906177,1018.282224056863,4.365474811452237,-0.3538,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB108(HCBF)-455W,Philadelphia Solar,Mono-c-Si,1,455.0,431.9,1.95,,,54.0,14.54,39.02,13.48,33.76,0.0071246,-0.08916070000000001,43.5,1.4059324554387713,14.55167858653924,1.2350330160585163e-11,0.05333239088752321,66.39955627474598,17.436618315384322,-0.3029,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M144(HC)-460W,Philadelphia Solar,Mono-c-Si,0,460.0,429.3,2.15,,,72.0,11.53,49.57,10.92,42.12,0.00598407,-0.13968826,45.4,1.8572394648940542,11.53000399194562,2.954202250288418e-11,0.148797525703073,429779.089531984,3.8098419670566166,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-460W,Philadelphia Solar,Mono-c-Si,1,460.0,428.9,2.15,,,72.0,11.42,49.84,10.91,42.12,0.00556154,-0.14872256000000003,44.1,1.9315344714481344,11.420003252063735,7.102706277490198e-11,0.1613979241051089,566787.3458738056,5.317540436782713,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-460W,Philadelphia Solar,Mono-c-Si,1,460.0,428.7,2.15,,,72.0,11.55,50.0,10.99,41.9,0.0060753000000000005,-0.1425,45.4,1.887957868850858,11.552177165023288,3.624411223035771e-11,0.2055913352220437,1090.6752667931614,4.338540191860986,-0.3538,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-465W,Philadelphia Solar,Mono-c-Si,0,465.0,434.1,2.15,,,72.0,11.59,49.6,10.96,42.42,0.00601521,-0.1397728,45.4,1.8625603894707086,11.590003087136337,3.153649628315489e-11,0.11977242398641029,449665.3019014104,4.316638857093493,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-465W,Philadelphia Solar,Mono-c-Si,1,465.0,433.7,2.15,,,72.0,11.55,49.9,10.95,42.43,0.005624850000000001,-0.1489016,44.1,1.932946031099487,11.550003568335349,7.0964550458653e-11,0.13372309541268393,432845.9015364075,5.213997015441778,-0.3758,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M132(HC)-500W,Philadelphia Solar,Mono-c-Si,0,500.0,468.7,2.17,,,66.0,13.91,45.69,13.25,37.75,0.00637078,-0.11120946,45.0,1.6657372544523252,13.912337324013647,1.6977285429542823e-11,0.21050339331986684,1252.7584111853937,13.37867293412939,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M132(HCBF)-500W,Philadelphia Solar,Mono-c-Si,0,500.0,465.4,2.17,,,66.0,13.91,45.69,13.25,37.75,0.0062455900000000005,-0.13081046999999998,45.5,1.7298323466018923,13.910544036893144,4.699593714969223e-11,0.19991733428784067,5111.5118588672985,4.571914177517199,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M132(HC)-505W,Philadelphia Solar,Mono-c-Si,0,505.0,473.5,2.17,,,66.0,13.96,45.86,13.3,37.98,0.0063936800000000005,-0.11162324,45.0,1.6737199542736094,13.962276146816476,1.754365701005223e-11,0.2028158102578276,1243.9043050176342,13.648592879893243,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M132(HCBF)-505W,Philadelphia Solar,Mono-c-Si,0,505.0,470.2,2.17,,,66.0,13.96,45.86,13.3,37.98,0.006268040000000001,-0.13129718,45.5,1.7382402440549987,13.960547830455326,4.8597935635678274e-11,0.192181431550361,4897.233504129295,4.825088203038718,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M132(HC)-510W,Philadelphia Solar,Mono-c-Si,0,510.0,478.4,2.17,,,66.0,14.01,46.09,13.36,38.18,0.00641658,-0.11218306000000001,45.0,1.6816074612213572,14.011304504699503,1.7480248735967954e-11,0.20232042103662304,2172.862438785661,13.577767152121528,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M132(HCBF)-510W,Philadelphia Solar,Mono-c-Si,0,510.0,475.0,2.17,,,66.0,14.01,46.09,13.36,38.18,0.00629049,-0.13195567,45.5,1.7469944553469827,14.010002669704464,4.882956000520401e-11,0.1905435504399479,999999.6683672232,4.832823520652381,-0.3702,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-MNB132(HCBF)-520W,Philadelphia Solar,Mono-c-Si,1,520.0,491.9,2.38,,,66.0,14.21,46.3,13.27,39.27,0.00647976,-0.1044065,43.4,1.663511606215359,14.227459865821709,1.1273812995432912e-11,0.13089420443515123,106.53040902427527,18.347763409761317,-0.3152,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-525W,Philadelphia Solar,Mono-c-Si,1,525.0,486.8,2.57,,,72.0,13.55,48.95,12.75,41.21,0.0074796,-0.13412300000000002,47.5,1.8298445304226048,13.561220414701486,3.208330238733799e-11,0.1588709307944951,191.85575431608805,6.128070722649046,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB132(HCBF)-525W,Philadelphia Solar,Mono-c-Si,1,525.0,496.7,2.38,,,66.0,14.26,46.47,13.36,39.38,0.00650256,-0.10478985,43.4,1.666370063929761,14.27566696183462,1.0757569824839178e-11,0.1342290535006258,122.17469639417017,17.844872039255094,-0.3152,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-530W,Philadelphia Solar,Mono-c-Si,0,530.0,488.3,2.56,,,72.0,13.6,49.2,12.79,41.46,0.0027472,-0.12423000000000001,47.3,1.8364629325237494,13.611551734310343,3.0921664695858006e-11,0.1561919611471813,183.88673303766308,15.323074144978742,-0.3694,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-530W,Philadelphia Solar,Mono-c-Si,1,530.0,490.5,2.56,,,72.0,13.6,49.2,12.79,41.46,0.0027744,-0.12910080000000002,45.3,1.8737114158897372,13.61052381360207,5.2718005673274275e-11,0.1497042375930206,193.4638647536934,15.815429066165814,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-530W,Philadelphia Solar,Mono-c-Si,1,530.0,491.6,2.57,,,72.0,13.6,49.2,12.79,41.46,0.0075072,-0.134808,47.5,1.8405977781713543,13.611435056583463,3.284314012411194e-11,0.15546937296859767,184.90363175843342,6.300600248519242,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB132(HCBF)-530W,Philadelphia Solar,Mono-c-Si,1,530.0,501.6,2.38,,,66.0,14.3,46.63,13.4,39.64,0.006520800000000001,-0.10515065000000001,43.4,1.6744690862486422,14.31445765603437,1.1219866103052928e-11,0.12375826576654504,122.40872232881976,18.223972717826065,-0.3152,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M144(HC)-535W,Philadelphia Solar,Mono-c-Si,0,535.0,493.1,2.56,,,72.0,13.65,49.5,12.83,41.72,0.0027573000000000003,-0.1249875,47.3,1.8483254193819325,13.661935167983579,3.1315064710304175e-11,0.15584960769650522,178.2419116721051,15.409271077554774,-0.3694,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-535W,Philadelphia Solar,Mono-c-Si,1,535.0,495.3,2.56,,,72.0,13.65,49.5,12.83,41.72,0.0027846000000000004,-0.129888,45.3,1.8858286740365238,13.660889459360286,5.338894361649113e-11,0.14933625183673332,187.19385372422852,15.90178651506883,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-535W,Philadelphia Solar,Mono-c-Si,1,535.0,496.3,2.57,,,72.0,13.65,49.5,12.83,41.72,0.0075348,-0.13563,47.5,1.8524911843288425,13.661816422654375,3.326228642970682e-11,0.1551236925578205,179.19453954333014,6.380642722378908,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB132(HCBF)-535W,Philadelphia Solar,Mono-c-Si,1,535.0,506.4,2.38,,,66.0,14.35,46.8,13.44,39.88,0.0065436,-0.105534,43.4,1.6829032845811305,14.363931217163056,1.1692148353116075e-11,0.11561814129722005,119.09370951093679,18.592540975910065,-0.3152,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M144(HC)-540W,Philadelphia Solar,Mono-c-Si,0,540.0,497.9,2.56,,,72.0,13.7,49.8,12.86,42.0,0.0027673999999999997,-0.125745,47.3,1.8613644331520547,13.71272586757738,3.2219526903802156e-11,0.15361243241000985,165.37106979083165,15.647183070472943,-0.3694,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-540W,Philadelphia Solar,Mono-c-Si,1,540.0,500.0,2.56,,,72.0,13.7,49.8,12.86,42.0,0.0027948,-0.13067520000000002,45.3,1.8991715218765106,13.711645059247665,5.4931659041343365e-11,0.14705665225937012,173.00694304299716,16.14007250752313,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-540W,Philadelphia Solar,Mono-c-Si,1,540.0,501.1,2.57,,,72.0,13.7,49.8,12.86,42.0,0.007562399999999999,-0.13645200000000002,47.5,1.865572195199512,13.712602956166371,3.4227120279355933e-11,0.15288036560019955,166.18807460917455,6.601688500222941,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB132(HCBF)-540W,Philadelphia Solar,Mono-c-Si,1,540.0,511.3,2.38,,,66.0,14.4,46.97,13.48,40.13,0.006566400000000001,-0.10591735000000001,43.4,1.6915407061106054,14.413249731768847,1.2220012504057129e-11,0.1066825944222569,115.94418578791338,18.990741206216576,-0.3152,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-545W,Philadelphia Solar,Mono-c-Si,0,545.0,502.6,2.56,,,72.0,13.75,50.1,12.9,42.26,0.0027775,-0.1265025,47.3,1.8732386900042273,13.76309457004586,3.26228073838862e-11,0.1532761490945021,160.94816833187645,15.731926043639215,-0.3694,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-545W,Philadelphia Solar,Mono-c-Si,1,545.0,504.8,2.56,,,72.0,13.75,50.1,12.9,42.26,0.0028050000000000006,-0.1314624,45.3,1.9113010721900467,13.761995775959495,5.561944827894215e-11,0.14669498497207645,168.14719373758396,16.22495092938499,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-545W,Philadelphia Solar,Mono-c-Si,1,545.0,505.9,2.57,,,72.0,13.75,50.1,12.9,42.26,0.00759,-0.137274,47.5,1.8774768842378662,13.762969579905821,3.4656555341793564e-11,0.1525408969949585,161.71975965578278,6.680284021868556,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-550W,Philadelphia Solar,Mono-c-Si,0,550.0,507.4,2.56,,,72.0,13.8,50.4,12.95,42.5,0.0027876000000000003,-0.12726,47.3,1.8839359957232926,13.813063791920655,3.251082162040943e-11,0.15482779751176975,163.55309644205397,15.664723733951242,-0.3694,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-550W,Philadelphia Solar,Mono-c-Si,1,550.0,509.6,2.56,,,72.0,13.8,50.4,12.95,42.5,0.0028152000000000003,-0.13224960000000002,45.3,1.9222046012308316,13.811964377759857,5.5428295991592525e-11,0.14823832250041666,170.98163505889127,16.15761712771566,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-550W,Philadelphia Solar,Mono-c-Si,1,550.0,510.7,2.57,,,72.0,13.8,50.4,12.95,42.5,0.0076176,-0.13809600000000002,47.5,1.8881936821346927,13.812938828657567,3.4535864263530536e-11,0.15409221672984316,164.3481540346709,6.617629721742746,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HC)-555W,Philadelphia Solar,Mono-c-Si,0,555.0,512.1,2.56,,,72.0,13.85,50.7,12.99,42.77,0.0027977,-0.1280175,47.3,1.8960396913675663,13.863365484890167,3.3018913844406085e-11,0.15360470795170678,159.1730667512378,15.778407525954325,-0.3694,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-555W,Philadelphia Solar,Mono-c-Si,1,555.0,514.4,2.56,,,72.0,13.85,50.7,12.99,42.77,0.0028254000000000005,-0.1330368,45.3,1.9345731933703227,13.862250954417254,5.629490174236578e-11,0.14698737399021616,166.17277974188514,16.27150602561039,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-555W,Philadelphia Solar,Mono-c-Si,1,555.0,515.4,2.57,,,72.0,13.85,50.7,12.99,42.77,0.0076452,-0.138918,47.5,1.9003314080562477,13.863238687246067,3.50778966729959e-11,0.15286523144047567,159.92397339552056,6.723387190709479,-0.3373,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-M144(HCBF)-560W,Philadelphia Solar,Multi-c-Si,1,560.0,519.2,2.56,,,72.0,13.9,50.98,13.04,43.0,0.0028356000000000006,-0.13377152000000003,45.3,1.9448743798240535,13.912177960439742,5.6223963261634385e-11,0.147854279717607,168.7617987263325,16.224832986459862,-0.3851,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M144(HCBF)-GG-560W,Philadelphia Solar,Mono-c-Si,1,560.0,520.2,2.57,,,72.0,13.9,50.98,13.04,43.0,0.0076728000000000005,-0.1396852,47.5,1.9104554616279579,13.913164494860819,3.503295739835919e-11,0.15373896648673852,162.32841981564314,6.6800826655290155,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-570W,Philadelphia Solar,Mono-c-Si,0,570.0,532.5,2.77,,,78.0,13.52,53.74,12.82,44.47,0.0064896,-0.13972400000000001,45.1,1.9761375350520949,13.52682924924926,2.076060034167845e-11,0.24645920483209646,487.9201712580741,8.080385636278658,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-570W,Philadelphia Solar,Mono-c-Si,1,570.0,533.9,2.77,,,78.0,13.56,53.6,12.69,44.93,0.0065088,-0.137752,44.6,1.98387098095096,13.577072095300169,2.442502817964134e-11,0.19433219943492056,154.35390866360066,10.842778708476223,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-570W,Philadelphia Solar,Multi-c-Si,1,570.0,535.5,2.77,,,78.0,13.56,53.6,12.69,44.93,0.0063732,-0.134,44.4,1.9539953142854731,13.578031915501636,1.6148832063455243e-11,0.19961335332030153,150.10923723955358,10.219225620366906,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-570W,Philadelphia Solar,Mono-c-Si,1,570.0,540.2,2.58,,,72.0,14.02,51.73,13.25,43.15,0.0058183,-0.11784093999999999,43.6,1.8010061846486949,14.033148493763806,4.634875785283511e-12,0.21779112442217344,232.22671977220682,9.028036353754578,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-575W,Philadelphia Solar,Mono-c-Si,0,575.0,537.3,2.77,,,78.0,13.57,53.99,12.87,44.69,0.0065136000000000005,-0.14037400000000003,45.1,1.9854344868390632,13.576636751295988,2.0871373782533477e-11,0.245531713580028,502.0325834503756,8.093921868012295,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-575W,Philadelphia Solar,Mono-c-Si,1,575.0,538.7,2.77,,,78.0,13.61,53.85,12.74,45.15,0.0065328,-0.1383945,44.6,1.9931111340154701,13.626862881628323,2.451751919606212e-11,0.19361124051969808,156.26326817770726,10.842641785417666,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-575W,Philadelphia Solar,Mono-c-Si,1,575.0,540.3,2.77,,,78.0,13.61,53.85,12.74,45.15,0.0063967,-0.134625,44.4,1.9630965050823306,13.627818519219002,1.620997917188795e-11,0.19889670863366019,151.91970659079928,10.219067809893936,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-575W,Philadelphia Solar,Mono-c-Si,1,575.0,545.0,2.58,,,72.0,14.06,51.51,13.29,43.39,0.0058349000000000005,-0.11733978,43.6,1.8014723593632784,14.071358939361275,5.287361539391664e-12,0.18001282524224052,222.8183676488651,10.193485212973794,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-580W,Philadelphia Solar,Mono-c-Si,0,580.0,542.0,2.77,,,78.0,13.62,54.24,12.92,44.91,0.006537599999999999,-0.141024,45.1,1.9947309662926,13.626446122915343,2.0982008702463374e-11,0.24461159881354172,516.8393569723856,8.107278458440684,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-580W,Philadelphia Solar,Mono-c-Si,1,580.0,543.5,2.77,,,78.0,13.65,54.12,12.79,45.35,0.0065520000000000005,-0.1390884,44.6,2.0015526937792383,13.666299011896033,2.4109049635495595e-11,0.1965015184772082,164.56492918208016,10.660666621446609,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-580W,Philadelphia Solar,Mono-c-Si,1,580.0,545.1,2.77,,,78.0,13.66,54.1,12.79,45.37,0.0064202,-0.13525,44.4,1.9721972408696145,13.67760720863917,1.627102816993596e-11,0.19818585048563842,153.75627081263082,10.21885685179695,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-580W,Philadelphia Solar,Mono-c-Si,1,580.0,549.9,2.58,,,72.0,14.1,51.65,13.33,43.64,0.0058515,-0.11765869999999999,43.6,1.8088007346749317,14.11069628344679,5.5098134961373544e-12,0.1687459296483806,222.4433961863013,10.542023237742972,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNG144(HCBF)-555W,Philadelphia Solar,Mono-c-Si,1,580.0,550.3,2.58,,,72.0,14.07,50.47,13.27,41.83,0.005867190000000001,-0.11476878,43.4,1.75221127989569,14.086521611198775,4.282625213472057e-12,0.23494455266798528,200.08156745061657,8.484795623515256,-0.3022,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNG144(HCBF)-560W,Philadelphia Solar,Mono-c-Si,1,580.0,550.3,2.58,,,72.0,14.13,50.67,13.35,41.95,0.00589221,-0.11522358,43.4,1.7568881572681754,14.144752603651364,4.15292587368776e-12,0.2388064528354346,228.7281122228357,8.163058925171104,-0.3022,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNG144(HCBF)-565W,Philadelphia Solar,Mono-c-Si,1,580.0,550.3,2.58,,,72.0,14.19,50.87,13.41,42.14,0.00591723,-0.11567837999999998,43.4,1.7641082442320049,14.204446484638497,4.1910503870714734e-12,0.23666356069321623,232.4618072854445,8.205970533210298,-0.3022,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNG144(HCBF)-570W,Philadelphia Solar,Mono-c-Si,1,580.0,550.3,2.58,,,72.0,14.25,51.07,13.48,42.29,0.0059422500000000005,-0.11613318,43.4,1.7699652329021307,14.263408585974062,4.140362255257405e-12,0.2379300559472583,252.8606160900016,8.054906745247738,-0.3022,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNG144(HCBF)-575W,Philadelphia Solar,Mono-c-Si,1,580.0,550.3,2.58,,,72.0,14.31,51.27,13.55,42.44,0.00596727,-0.11658798000000001,43.4,1.7758266091720467,14.322356452351334,4.090934105930236e-12,0.23918202804438288,276.9965633258026,7.905626837134559,-0.3022,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNG144(HCBF)-580W,Philadelphia Solar,Mono-c-Si,1,580.0,550.3,2.58,,,72.0,14.37,51.47,13.62,42.59,0.00599229,-0.11704278,43.4,1.7816922905799157,14.381290290670803,4.04272427934858e-12,0.2404197278579489,306.00022441048395,7.758098708379665,-0.3022,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-585W,Philadelphia Solar,Mono-c-Si,0,585.0,546.8,2.77,,,78.0,13.67,54.49,12.97,45.11,0.006561600000000001,-0.14167400000000002,45.1,2.0035831164062086,13.676266996590922,2.0966749552038854e-11,0.2454703054008167,535.4365379297925,8.067791113028278,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-585W,Philadelphia Solar,Mono-c-Si,1,585.0,548.3,2.77,,,78.0,13.71,54.35,12.84,45.57,0.0065808,-0.1396795,44.6,2.011143764588647,13.72658335108933,2.4555410651508508e-11,0.19397550129101895,160.36590387731442,10.788488831541105,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-585W,Philadelphia Solar,Mono-c-Si,1,585.0,549.9,2.77,,,78.0,13.71,54.35,12.84,45.57,0.0064437,-0.135875,44.4,1.9808647573569944,13.727534740702382,1.623505347418596e-11,0.1992654513953419,155.80095512921417,10.165038704064518,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-585W,Philadelphia Solar,Mono-c-Si,1,585.0,554.8,2.58,,,72.0,14.14,51.79,13.37,43.89,0.0058681,-0.11797762,43.6,1.816124033019153,14.150029543995805,5.739361936128328e-12,0.15755147289702243,222.12154389425163,10.887974038947332,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-590W,Philadelphia Solar,Mono-c-Si,0,590.0,551.6,2.77,,,78.0,13.72,54.74,13.02,45.36,0.006585600000000001,-0.142324,45.1,2.0135443208515906,13.726065901115195,2.1266002913114856e-11,0.24191089216346362,547.1598381249407,8.159662245465794,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-590W,Philadelphia Solar,Mono-c-Si,1,590.0,553.2,2.77,,,78.0,13.76,54.6,12.89,45.82,0.0066048,-0.140322,44.6,2.021051670367578,13.77618193624403,2.4867587769452595e-11,0.19059223473286183,162.06646252405184,10.868615423667311,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-590W,Philadelphia Solar,Mono-c-Si,1,590.0,554.7,2.77,,,78.0,13.76,54.6,12.89,45.82,0.0064672,-0.1365,44.4,1.9906135111550876,13.777123067646665,1.6441406447636757e-11,0.19589242734037426,157.41804367493899,10.24490443356062,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-590W,Philadelphia Solar,Mono-c-Si,1,590.0,559.6,2.58,,,72.0,14.18,51.93,13.41,44.14,0.0058847000000000005,-0.11829653999999999,43.6,1.8234423184513437,14.18935929580549,5.976153166619681e-12,0.14642871025312565,221.84992995994065,11.23136533284609,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-595W,Philadelphia Solar,Mono-c-Si,0,595.0,556.5,2.77,,,78.0,13.77,54.99,13.07,45.58,0.006609599999999999,-0.14297400000000002,45.1,2.022839334160384,13.77588132519738,2.137624017214602e-11,0.24101582225722573,564.2925360962454,8.172369823028333,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-595W,Philadelphia Solar,Mono-c-Si,1,595.0,558.0,2.77,,,78.0,13.81,54.85,12.94,46.04,0.0066288,-0.1409645,44.6,2.030289802545106,13.825981742335046,2.4959376920104462e-11,0.18989767161917936,164.09267550422686,10.86812752350827,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-595W,Philadelphia Solar,Mono-c-Si,1,595.0,559.5,2.77,,,78.0,13.81,54.85,12.94,46.04,0.0064907,-0.137125,44.4,1.9997127444184493,13.826918740124041,1.6502090145985584e-11,0.19520202248006685,159.33455571119725,10.244398349953643,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-595W,Philadelphia Solar,Mono-c-Si,1,595.0,564.5,2.58,,,72.0,14.22,52.07,13.44,44.34,0.005901300000000001,-0.11861546000000002,43.6,1.8304160939543401,14.229388633091215,6.18282588134554e-12,0.1394974289169685,211.28245468450288,11.520137542167635,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-600W,Philadelphia Solar,Mono-c-Si,0,600.0,561.3,2.77,,,78.0,13.82,55.24,13.12,45.77,0.006633600000000001,-0.143624,45.1,2.031469106526253,13.82570785637328,2.1297424358593002e-11,0.24275404635631562,587.7619815393492,8.107097393073577,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-600W,Philadelphia Solar,Mono-c-Si,1,600.0,562.8,2.77,,,78.0,13.86,55.1,12.99,46.26,0.0066528,-0.141607,44.6,2.0395274768552234,13.875783484863234,2.505102296097302e-11,0.18920863200537477,166.1503575539884,10.867590921737197,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-600W,Philadelphia Solar,Mono-c-Si,1,600.0,564.4,2.77,,,78.0,13.86,55.1,12.99,46.26,0.0065142,-0.13775,44.4,2.008811524029033,13.876716357549714,1.6562677164405804e-11,0.19451710705174277,161.27957919841285,10.24384329741261,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-600W,Philadelphia Solar,Mono-c-Si,1,600.0,569.3,2.58,,,72.0,14.26,52.21,13.47,44.57,0.0059179,-0.11893438,43.6,1.8379735690488395,14.26921523441692,6.452677029147091e-12,0.13006974642053112,201.27481358075295,11.889919275967856,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HC)-605W,Philadelphia Solar,Mono-c-Si,0,605.0,566.1,2.77,,,78.0,13.87,55.49,13.17,45.98,0.0066576,-0.14260930000000002,45.1,2.039226685302274,13.875560010122056,2.0972967679398644e-11,0.2429551518172309,606.0758873955823,9.20892410195992,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-605W,Philadelphia Solar,Mono-c-Si,1,605.0,569.2,2.77,,,78.0,13.91,55.35,13.04,46.46,0.0065377000000000005,-0.138375,44.4,2.0174781659594827,13.92664545216946,1.65265455221376e-11,0.19559440339928727,163.45114175101813,10.190781022135386,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB144(HCBF)-605W,Philadelphia Solar,Mono-c-Si,1,605.0,574.2,2.58,,,72.0,14.3,52.35,13.51,44.8,0.005934500000000001,-0.11925330000000002,43.6,1.8448987287154988,14.30856927859024,6.67268448993576e-12,0.12079927496995861,201.58402086785924,12.172463765566834,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-M156(HCBF)-GG-610W,Philadelphia Solar,Mono-c-Si,1,610.0,574.0,2.77,,,78.0,13.96,55.6,13.09,46.66,0.0065612,-0.139,44.4,2.02614474542784,13.976572369529615,1.649108703587114e-11,0.1966634898633657,165.66262985109108,10.13818983973556,-0.327,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-615W,Philadelphia Solar,Mono-c-Si,1,615.0,579.7,2.79,,,78.0,13.99,55.5,13.21,46.48,0.00398715,-0.1242645,43.2,1.9970893587894123,14.001596154977047,1.1749508247745487e-11,0.2078067850598219,250.7052507606871,19.916917967126263,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-620W,Philadelphia Solar,Mono-c-Si,1,620.0,584.5,2.79,,,78.0,14.02,55.65,13.25,46.75,0.0039957,-0.12460035,43.2,2.0046362656535606,14.030359709458985,1.213989239719695e-11,0.1955585845786307,264.65330674739084,20.211654263893934,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-625W,Philadelphia Solar,Mono-c-Si,1,625.0,589.3,2.79,,,78.0,14.06,55.8,13.29,47.01,0.0040071,-0.12493619999999998,43.2,2.0126346091200964,14.069794550558195,1.2617338796698497e-11,0.18403849462001057,264.18580735651307,20.561567416076127,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-630W,Philadelphia Solar,Mono-c-Si,1,630.0,594.2,2.79,,,78.0,14.1,55.95,13.33,47.27,0.0040184999999999995,-0.12527205,43.2,2.0206289103457142,14.10922560507076,1.3109061739007783e-11,0.17259233596026727,263.7823608471491,20.909080880800538,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-635W,Philadelphia Solar,Mono-c-Si,1,635.0,599.0,2.79,,,78.0,14.14,56.1,13.37,47.52,0.0040299,-0.1256079,43.2,2.028414588483508,14.148689946598228,1.357766267030904e-11,0.1620721403599753,263.71854291019775,21.226842658450195,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-640W,Philadelphia Solar,Mono-c-Si,1,640.0,603.9,2.79,,,78.0,14.18,56.25,13.41,47.78,0.0040413,-0.12594375,43.2,2.036401219326181,14.188115732395676,1.4097581987030543e-11,0.1507687212388862,263.42668410255067,21.569738846188216,-0.3399,N,2025.7.3,6/23/2025,2.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-645W,Philadelphia Solar,Mono-c-Si,1,645.0,608.7,2.79,,,78.0,14.22,56.4,13.44,48.0,0.004052700000000001,-0.1262796,43.2,2.0442868108525327,14.22813961272623,1.460176811835831e-11,0.14280483828727533,249.48174372230494,21.8932020355803,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Philadelphia Solar PS-MNB156(HCBF)-650W,Philadelphia Solar,Mono-c-Si,1,650.0,613.6,2.79,,,78.0,14.26,56.55,13.48,48.22,0.0040641,-0.12661545,43.2,2.05145287197464,14.267690882217105,1.4987681827989573e-11,0.13500418274816747,250.31714214630173,22.123623445157733,-0.3399,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS160M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,160.0,145.1,1.2766400000000002,1.58,0.808,72.0,5.05,43.8,4.63,34.6,0.0031815,-0.13183799999999998,45.3,1.7686206335378776,5.070540127588879,8.546042788758774e-11,0.8673116002647008,213.23741836577116,13.115545890458586,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS165M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,165.0,149.7,1.2766400000000002,1.58,0.808,72.0,5.1,44.0,4.71,35.0,0.0032129999999999997,-0.13244,45.3,1.777053985338393,5.115140736265635,8.742209926925534e-11,0.8010864750552098,269.8376826373384,13.210493228230451,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS170M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,170.0,154.4,1.2766400000000002,1.58,0.808,72.0,5.15,44.2,4.8,35.4,0.0032445000000000004,-0.13304200000000002,45.3,1.7836317511674016,5.15925107719879,8.734038491725444e-11,0.7370884230808326,410.33120387013884,13.082193414256148,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS180M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,180.0,163.7,1.2766400000000002,1.58,0.808,72.0,5.25,44.6,4.98,36.2,0.0033075,-0.134246,45.3,1.7971773174002073,5.25000323436981,8.757950967558421e-11,0.6159862178955265,999999.9342137458,12.869497644001372,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS185M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,185.0,168.3,1.2766400000000002,1.58,0.808,72.0,5.3,44.8,5.06,36.6,0.003339,-0.13484799999999997,45.3,1.815929717557786,5.300002702468765,1.023257830238678e-10,0.5098334045444721,999999.7225398805,14.20965822158204,-0.419,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS190M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,190.0,173.0,1.2766400000000002,1.58,0.808,72.0,5.35,45.0,5.14,37.0,0.0033705,-0.13545,45.3,1.8355256566249898,5.350147579927301,1.20472480978998e-10,0.39600125648928597,14355.681761800999,15.640112934092189,-0.419,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS195M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,195.0,176.3,1.2766400000000002,1.58,0.808,72.0,5.4,45.2,5.22,37.4,0.002808,-0.159556,45.3,1.9190964920932654,5.4000013165819745,3.188312267480383e-10,0.24375312650590278,999999.395114558,6.583581386934284,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS200M-24/F,Phono Solar Technology Co Ltd,Mono-c-Si,0,200.0,180.9,1.2766400000000002,1.58,0.808,72.0,5.45,45.4,5.3,37.8,0.0028339999999999997,-0.160262,45.3,1.9391661274355254,5.45000065066855,3.7037032956871744e-10,0.11936155898774412,999999.485339785,7.802258541896337,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS210M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,210.0,189.7,1.6268799999999999,1.64,0.992,60.0,7.85,36.7,7.3,28.8,0.0049455,-0.11046700000000001,46.2,1.465820023938149,7.868015044708129,1.0301662249963945e-10,0.49738741676973103,216.735044565582,10.762936064284062,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS210P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,210.0,190.1,1.6268799999999999,1.64,0.992,60.0,7.9,36.5,7.35,28.6,0.006399,-0.11315,46.1,1.4714254378543798,7.916985270313338,1.3082919974751925e-10,0.4942108260874303,229.86186566881074,9.334145011116213,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS215M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,215.0,194.3,1.6268799999999999,1.64,0.992,60.0,7.95,36.9,7.42,29.0,0.0050085,-0.111069,46.2,1.472386666715422,7.964142037410714,1.0226138454643911e-10,0.4865000876103584,273.48789590838834,10.571638167353406,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS215P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,215.0,194.7,1.6268799999999999,1.64,0.992,60.0,8.0,36.7,7.47,28.8,0.0064800000000000005,-0.11377000000000001,46.1,1.4780998332021338,8.013096255869142,1.2996840241374523e-10,0.483402966214994,295.29235341911954,9.153258350705512,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS220M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,220.0,199.0,1.6268799999999999,1.64,0.992,60.0,8.05,37.0,7.54,29.2,0.0050715000000000005,-0.11137,46.2,1.4772366102866028,8.060403883421165,1.0545707582156494e-10,0.462344502954778,357.7388873410448,10.72392801843091,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS220P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,220.0,199.4,1.6268799999999999,1.64,0.992,60.0,8.1,36.9,7.59,29.0,0.006561,-0.11438999999999999,46.1,1.4848285372899175,8.10933844679423,1.2922152029344193e-10,0.4729125834965227,410.1958984317527,8.981607812977638,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS225M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,225.0,203.6,1.6268799999999999,1.64,0.992,60.0,8.15,37.1,7.66,29.4,0.0051345,-0.11167099999999999,46.2,1.4821175269826463,8.156970360466973,1.0877040939314955e-10,0.43894520006659055,513.2308386106793,10.879363764592519,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS225P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,225.0,204.0,1.6268799999999999,1.64,0.992,60.0,8.2,37.0,7.71,29.2,0.0066419999999999995,-0.1147,46.1,1.4898471060616159,8.205852025430506,1.3347575206727793e-10,0.44942824966997186,629.7499223715944,9.149705114955905,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS230M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,230.0,208.2,1.6268799999999999,1.64,0.992,60.0,8.25,37.3,7.78,29.6,0.0051975,-0.112273,46.2,1.4888243872158753,8.25366777634918,1.0816575364601744e-10,0.4294099692721692,965.8803851599098,10.708446168816677,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS230MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,230.0,207.5,1.6268799999999999,1.64,0.992,60.0,8.37,36.8,7.83,29.4,0.0041012999999999996,-0.163024,45.3,1.53903892702123,8.379584723544273,3.4111642268878236e-10,0.3731285543451751,325.8400432683392,-17.618252640078175,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS230P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,230.0,208.6,1.6268799999999999,1.64,0.992,60.0,8.3,37.1,7.83,29.4,0.006723000000000001,-0.11501,46.1,1.4948921140252847,8.302662637867583,1.3788051931906245e-10,0.4266651697324362,1330.0053717967241,9.320113161232076,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS230PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,230.0,207.3,1.6268799999999999,1.64,0.992,60.0,8.3,37.1,7.83,29.4,0.004731000000000001,-0.130963,45.4,1.5369572053782385,8.301209932855127,2.7239439037917963e-10,0.4157468998725811,2851.981233252656,1.5936701365657215,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS235M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,235.0,212.8,1.6268799999999999,1.64,0.992,60.0,8.35,37.5,7.9,29.8,0.0052605,-0.112875,46.2,1.4955788170468542,8.350477407354479,1.0764344313264679e-10,0.4201437476314131,7348.456590417795,10.54585036311241,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS235MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,235.0,212.1,1.6268799999999999,1.64,0.992,60.0,8.43,36.9,7.9,29.8,0.0041307,-0.163467,45.3,1.5519147043118573,8.437769081624444,3.9312186857306117e-10,0.32343199713289555,350.9465490975468,-16.719731330045594,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS235P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,235.0,213.3,1.6268799999999999,1.64,0.992,60.0,8.4,37.3,7.94,29.6,0.006804000000000001,-0.11563,46.1,1.502673521918196,8.40076373358922,1.3920560119162737e-10,0.4175497518019779,4592.470359581121,9.292512548610338,-0.413,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS235PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,235.0,211.9,1.6268799999999999,1.64,0.992,60.0,8.4,37.3,7.94,29.6,0.004788000000000001,-0.13166899999999998,45.4,1.5453889659740292,8.40530622982003,2.7687373330393045e-10,0.4065064948213639,999999.9218633511,1.620511553102963,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS240M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,240.0,217.5,1.6268799999999999,1.64,0.992,60.0,8.45,37.6,8.0,30.0,0.005323499999999999,-0.113176,46.2,1.5023836398380925,8.450204901463813,1.1421063777581098e-10,0.3985373560960148,16435.49148519775,10.968118410346248,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS240M-20/U-AC,Phono Solar Technology Co Ltd,Mono-c-Si,0,240.0,217.5,1.6268799999999999,1.64,0.992,60.0,8.45,37.6,8.0,30.0,0.005323499999999999,-0.113176,46.2,1.5023836398380925,8.450204901463813,1.1421063777581098e-10,0.3985373560960148,16435.49148519775,10.968118410346248,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS240MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,240.0,216.7,1.6268799999999999,1.64,0.992,60.0,8.49,37.1,7.95,30.2,0.0041601,-0.164353,45.3,1.5685830490262231,8.49799090486804,4.478797399777382e-10,0.28728171372293526,305.224789974976,-15.882668680466768,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS240P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,240.0,217.9,1.6268799999999999,1.64,0.992,60.0,8.5,37.5,8.06,29.8,0.0068850000000000005,-0.11624999999999999,46.1,1.5128329920304364,8.500003397499677,1.4593366206775926e-10,0.3995452920804376,999999.3349242647,9.603623834678958,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS240P-20/U-AC,Phono Solar Technology Co Ltd,Multi-c-Si,0,240.0,217.9,1.6268799999999999,1.64,0.992,60.0,8.5,37.5,8.06,29.8,0.0068850000000000005,-0.11624999999999999,46.1,1.5128329920304364,8.500003397499677,1.4593366206775926e-10,0.3995452920804376,999999.3349242647,9.603623834678958,-0.413,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS240PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,240.0,216.5,1.6268799999999999,1.64,0.992,60.0,8.5,37.5,8.06,29.8,0.004845,-0.132375,45.4,1.5575582737682214,8.500003258583668,2.973582109806615e-10,0.38311396726714086,999999.9733129129,2.1148939665569366,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245M,Phono Solar Technology Co Ltd,Mono-c-Si,0,245.0,218.8,1.6268799999999999,1.64,0.992,60.0,8.55,37.8,8.13,30.2,0.004275,-0.1323,46.2,1.6075694956475794,8.550002900660497,5.248908689729896e-10,0.3389410095603403,999991.2053755211,7.865271954543121,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,245.0,221.4,1.6268799999999999,1.64,0.992,60.0,8.55,37.8,8.13,30.2,0.0017100000000000001,-0.12474,45.4,1.5106940638263078,8.550003205815235,1.1620278676068254e-10,0.37484925508072386,999999.9229033183,1.708249419911332,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245M-20/U-AC,Phono Solar Technology Co Ltd,Mono-c-Si,0,245.0,221.4,1.6268799999999999,1.64,0.992,60.0,8.55,37.8,8.13,30.2,0.0017100000000000001,-0.12474,45.4,1.5106940638263078,8.550003205815235,1.1620278676068254e-10,0.37484925508072386,999999.9229033183,1.708249419911332,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,245.0,221.4,1.6268799999999999,1.64,0.992,60.0,8.55,37.8,8.13,30.2,0.0041895000000000005,-0.167454,45.3,1.576584811644417,8.550002998074316,3.3065434794258435e-10,0.35042591989506516,999992.1000242985,-17.993162181660153,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,245.0,221.3,1.6268799999999999,1.64,0.992,60.0,8.6,37.7,8.18,30.0,0.004902,-0.130442,45.4,1.5642706672916213,8.60000313167997,2.9356258464327113e-10,0.3639304325340255,999999.7984768449,3.988985422818964,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245P-20/U-AC,Phono Solar Technology Co Ltd,Multi-c-Si,0,245.0,221.3,1.6268799999999999,1.64,0.992,60.0,8.6,37.7,8.18,30.0,0.004902,-0.130442,45.4,1.5642706672916213,8.60000313167997,2.9356258464327113e-10,0.3639304325340255,999999.7984768449,3.988985422818964,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS245PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,245.0,221.2,1.6268799999999999,1.64,0.992,60.0,8.6,37.7,8.18,30.0,0.004902,-0.133081,45.4,1.5691925392338881,8.60000311616591,3.166142603118733e-10,0.36211371441385204,999999.7979159286,2.536646291545251,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 250P-20/UV,Phono Solar Technology Co Ltd,Multi-c-Si,0,250.0,223.8,1.6268799999999999,1.64,0.992,60.0,8.85,37.5,8.31,30.1,0.004425,-0.1275,46.3,1.5811417800494385,8.856177207934461,4.3978320188035813e-10,0.3367167227425456,482.40951749135064,9.202971036097972,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS250M,Phono Solar Technology Co Ltd,Mono-c-Si,0,250.0,223.4,1.6268799999999999,1.64,0.992,60.0,8.65,37.9,8.24,30.4,0.004325000000000001,-0.13265,46.2,1.6162786553948043,8.65000270199991,5.665976799980646e-10,0.31208727670831216,999999.6954919222,8.431943690905264,-0.48,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS250M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,250.0,226.0,1.6268799999999999,1.64,0.992,60.0,8.65,37.9,8.24,30.4,0.0017300000000000002,-0.12507000000000001,45.4,1.518648622906033,8.65000301285116,1.2548397297928848e-10,0.348215449441806,999999.7075396987,2.2409213598002533,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS250M-20/U-AC,Phono Solar Technology Co Ltd,Mono-c-Si,0,250.0,226.0,1.6268799999999999,1.64,0.992,60.0,8.65,37.9,8.24,30.4,0.0017300000000000002,-0.12507000000000001,45.4,1.518648622906033,8.65000301285116,1.2548397297928848e-10,0.348215449441806,999999.7075396987,2.2409213598002533,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS250MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,250.0,226.0,1.6268799999999999,1.64,0.992,60.0,8.65,37.9,8.24,30.4,0.004238500000000001,-0.167897,45.3,1.5853050648370184,8.65000280043665,3.583484535748404e-10,0.3235491106253883,999999.7000768747,-17.53711183748317,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS250P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,250.0,223.7,1.63,,,60.0,8.7,37.8,8.3,30.2,0.005916,-0.135324,48.1,1.5656171848491207,8.700002913837702,2.8443564888561107e-10,0.3347460698458813,999998.6758645602,0.0006430530942262502,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS250P-20/U-AC,Phono Solar Technology Co Ltd,Multi-c-Si,0,250.0,225.9,1.6268799999999999,1.64,0.992,60.0,8.7,37.8,8.3,30.2,0.004959,-0.130788,45.4,1.573641790507203,8.700002888082658,3.2170202856396894e-10,0.33176856908944835,999998.6672005701,4.662628574070233,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS250PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,250.0,225.8,1.6268799999999999,1.64,0.992,60.0,8.7,37.8,8.3,30.2,0.004959,-0.133434,45.4,1.578625483069213,8.70000287209364,3.470464754818195e-10,0.3299193880868796,999998.6642027709,3.202985631797562,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 255P-20/UV,Phono Solar Technology Co Ltd,Multi-c-Si,0,255.0,228.5,1.6268799999999999,1.64,0.992,60.0,8.95,37.8,8.39,30.5,0.004475,-0.12852000000000002,46.3,1.6000442639018924,8.957645891996693,4.866773361382869e-10,0.3130956465489209,366.49836108448113,10.008627855024258,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS255M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,255.0,230.6,1.6268799999999999,1.64,0.992,60.0,8.75,38.0,8.35,30.6,0.0035875000000000004,-0.16834000000000002,45.4,1.5774236226717004,8.750002655656504,3.019182858301442e-10,0.3033522141375832,999999.1974393238,-18.652659045706915,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS255M-20/U-AC,Phono Solar Technology Co Ltd,Mono-c-Si,0,255.0,230.6,1.6268799999999999,1.64,0.992,60.0,8.75,38.0,8.35,30.6,0.0035875000000000004,-0.16834000000000002,45.4,1.5774236226717004,8.750002655656504,3.019182858301442e-10,0.3033522141375832,999999.1974393238,-18.652659045706915,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS255MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,255.0,230.7,1.6268799999999999,1.64,0.992,60.0,8.75,38.0,8.35,30.6,0.0042875000000000005,-0.16834000000000002,45.3,1.594013034355373,8.750002602291952,3.879467026040468e-10,0.29722224471826514,999999.1930555734,-17.08467766033531,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS255P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,255.0,228.4,1.63,,,60.0,8.8,37.9,8.42,30.4,0.005984000000000001,-0.135682,48.1,1.5750055311614743,8.800002667295008,3.117997881252468e-10,0.30293166269354527,999957.2073381407,0.6532143505999825,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS255P-20/U-AC,Phono Solar Technology Co Ltd,Multi-c-Si,0,255.0,230.5,1.6268799999999999,1.64,0.992,60.0,8.8,37.9,8.42,30.4,0.0050160000000000005,-0.131134,45.4,1.5829907316428542,8.800002641126285,3.5204047338557e-10,0.29995152238485157,999985.0101474168,5.329893813647169,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS255PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,255.0,230.4,1.6268799999999999,1.64,0.992,60.0,8.8,37.9,8.42,30.4,0.0050160000000000005,-0.133787,45.4,1.5880365825225675,8.800002624710416,3.7986650353655283e-10,0.2980683701047109,999959.0751707532,3.8630845821399604,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 260M-20/UV,Phono Solar Technology Co Ltd,Mono-c-Si,0,260.0,232.2,1.6268799999999999,1.64,0.992,60.0,9.14,38.1,8.47,30.7,0.0036560000000000004,-0.13335,46.5,1.6260424535904265,9.157739530986426,5.948812997414891e-10,0.31300813095426144,161.2722895821728,8.565559083948637,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 260P-20/UV,Phono Solar Technology Co Ltd,Multi-c-Si,0,260.0,233.1,1.6268799999999999,1.64,0.992,60.0,9.01,38.0,8.42,30.7,0.004505,-0.1292,46.3,1.6123767276122343,9.02025077269753,5.164952852411086e-10,0.3070237463869806,269.8610800106025,10.490810253495924,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS260M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,260.0,234.6,1.63,,,60.0,9.37,39.1,8.44,30.92,0.005621999999999999,-0.121601,48.4,1.5701939022328866,9.430528132383715,1.3531576055063517e-10,0.41946992201597855,64.93564417817504,8.154765743884038,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS260M-20/U-AC,Phono Solar Technology Co Ltd,Mono-c-Si,0,260.0,235.2,1.6268799999999999,1.64,0.992,60.0,8.85,38.1,8.46,30.8,0.0036284999999999998,-0.16878300000000002,45.4,1.5859589654467663,8.850002457954803,3.263969829994422e-10,0.2775976898604658,999997.8604763986,-18.21557387183162,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS260M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,260.0,234.2,1.9403519999999999,1.956,0.992,72.0,8.05,44.3,7.32,35.5,0.0033005,-0.196249,45.4,1.8675444999714927,8.083439691413236,3.8310783322785385e-10,0.4532299670582947,109.10691258480198,-16.41235344861665,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS260MB-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,260.0,235.3,1.6268799999999999,1.64,0.992,60.0,8.85,38.1,8.46,30.8,0.0043365,-0.16878300000000002,45.3,1.6027091478723594,8.850002403496577,4.195514341556336e-10,0.27141615860491014,999997.8452565818,-16.635788729250205,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS260P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,260.0,233.0,1.63,,,60.0,8.9,38.0,8.54,30.6,0.006052000000000001,-0.13604,48.1,1.5848713286908447,8.900218809798984,3.437786735044525e-10,0.2698477657859032,10976.00966881952,1.3596708486933637,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS260P-20/U-AC,Phono Solar Technology Co Ltd,Multi-c-Si,0,260.0,235.2,1.6268799999999999,1.64,0.992,60.0,8.9,38.0,8.54,30.6,0.005073000000000001,-0.13147999999999999,45.4,1.5928084712853943,8.900216701215406,3.874070226842302e-10,0.26685761899370564,10960.009494006843,6.051854136862559,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS260P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,260.0,234.1,1.9403519999999999,1.956,0.992,72.0,8.1,44.0,7.38,35.2,0.0046170000000000004,-0.15224,45.4,1.8619936101998926,8.132148191557587,4.2318631779384004e-10,0.4540704201334282,114.40676875883003,7.753717398073808,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS260PB-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,260.0,235.1,1.6268799999999999,1.64,0.992,60.0,8.9,38.0,8.54,30.6,0.005073000000000001,-0.13413999999999998,45.4,1.5979219045818616,8.90021521137387,4.181415283064828e-10,0.2649320617489771,10956.25532625059,4.577413454747729,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 265M-20/UV,Phono Solar Technology Co Ltd,Mono-c-Si,0,265.0,236.8,1.6268799999999999,1.64,0.992,60.0,9.16,38.3,8.56,30.95,0.003664,-0.13405,46.5,1.6298641480936564,9.170270944791337,5.625507067763736e-10,0.302244109763116,269.55229334157775,8.028592686433887,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 265P-20/UV,Phono Solar Technology Co Ltd,Multi-c-Si,0,265.0,237.7,1.6268799999999999,1.64,0.992,60.0,9.2,38.3,8.47,30.89,0.0046,-0.13022,46.3,1.636821731977767,9.223477376020261,6.133213380230352e-10,0.30913740061468437,121.14064328311468,11.901270522088303,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS265M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,265.0,239.2,1.63,,,60.0,9.43,39.2,8.55,31.08,0.005658,-0.121912,48.4,1.5710558855536785,9.48171800303112,1.3053011845329672e-10,0.40639130235831084,74.0993437074442,7.765524630803664,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS265P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,265.0,237.6,1.63,,,60.0,9.0,38.1,8.59,30.8,0.0061200000000000004,-0.136398,48.1,1.587354457740062,9.000002512543487,3.3901393524875756e-10,0.2790257275857821,999999.3509539624,1.1528015413152022,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 270M-20/UV,Phono Solar Technology Co Ltd,Mono-c-Si,0,270.0,241.5,1.6268799999999999,1.64,0.992,60.0,9.2,38.6,8.68,31.09,0.00368,-0.1351,46.5,1.6311192595268307,9.202022068458772,4.843501986696195e-10,0.31791241252361985,1446.438517529641,6.6582058644040405,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 270P-20/UV,Phono Solar Technology Co Ltd,Multi-c-Si,0,270.0,242.3,1.6268799999999999,1.64,0.992,60.0,9.31,38.5,8.57,31.11,0.004655,-0.13090000000000002,46.3,1.647361121410134,9.333362417098943,6.382079946358642e-10,0.29892679026047386,119.1233227854255,12.155400438590958,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS270M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,270.0,243.9,1.63,,,60.0,9.48,39.3,8.66,31.24,0.005688,-0.12222299999999998,48.4,1.5711632477660582,9.522135493204695,1.244179603533101e-10,0.3939841013203486,88.64188132761926,7.279918863303439,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS270M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,270.0,243.4,1.9403519999999999,1.956,0.992,72.0,8.15,44.7,7.54,35.8,0.0033415000000000003,-0.19802100000000003,45.4,1.8651840552152126,8.169377583234912,3.101386395711603e-10,0.45620736216575436,191.87585644159108,-17.948626373789978,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS270P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,270.0,242.2,1.63,,,60.0,9.09,38.39,8.61,31.44,0.0061812,-0.1374362,48.1,1.604891105910207,9.090575076223407,3.7114380004063834e-10,0.25613048507742325,4048.556383704491,1.8173389050090893,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS270P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,270.0,243.3,1.9403519999999999,1.956,0.992,72.0,8.2,44.4,7.61,35.5,0.004673999999999999,-0.15362399999999998,45.4,1.8593602402929486,8.216625691800711,3.416256721778281e-10,0.4566652234721872,225.23305357470974,5.739890375873617,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 275M-20/UV,Phono Solar Technology Co Ltd,Mono-c-Si,0,275.0,246.1,1.6268799999999999,1.64,0.992,60.0,9.23,38.9,8.81,31.22,0.0036920000000000004,-0.13615,46.5,1.6382323019031841,9.32002792781632,4.5399053992872e-10,0.3314513344037759,999999.9266607169,5.9884384487114986,-0.48,N,2025.7.3,6/23/2025,-2.0,bootstrapping +Phono Solar Technology Co Ltd PS275M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,275.0,248.5,1.63,,,60.0,9.54,39.4,8.77,31.4,0.005724,-0.122534,48.4,1.5722731417651332,9.574316221531465,1.2045398732198092e-10,0.3814591979166999,106.04666536521586,6.925372893352271,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS275P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,275.0,246.8,1.63,,,60.0,9.17,38.68,8.66,31.79,0.006235600000000001,-0.1384744,48.1,1.6229403250807375,9.172707849959139,4.069825018469437e-10,0.2401779495592937,813.3511030866491,2.5181683776183434,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 280M-20/UV,Phono Solar Technology Co Ltd,Mono-c-Si,0,280.0,250.7,1.6268799999999999,1.64,0.992,60.0,9.28,39.1,8.91,31.43,0.003712,-0.13685,46.5,1.6611889195282437,9.28022075742648,5.562177980808484e-10,0.2587068481288525,10875.371941083851,7.7721037815683465,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS280M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,280.0,253.2,1.63,,,60.0,9.59,39.5,8.88,31.56,0.005754,-0.12284500000000001,48.4,1.5726447781023796,9.61577244111211,1.15258195188081e-10,0.3695680204516192,137.51733628305146,6.4768168826355925,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS280M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,280.0,252.6,1.9403519999999999,1.956,0.992,72.0,8.3,45.1,7.75,36.1,0.003403,-0.199793,45.4,1.8716428276728811,8.311642643285367,2.8015621392203046e-10,0.45544586878077786,324.6858187315312,-18.76115811563294,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS280MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,280.0,252.7,1.9403519999999999,1.956,0.992,72.0,8.3,45.1,7.75,36.1,0.004067,-0.199793,45.3,1.890314612712105,8.311090904853556,3.556416220335308e-10,0.45051749141351827,337.14976140379076,-17.27938709668717,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS280P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,280.0,251.5,1.63,,,60.0,9.25,39.02,8.73,32.1,0.0062900000000000005,-0.1396916,48.1,1.6386786189214086,9.25314976662383,4.190595730259735e-10,0.23598616257326763,693.026840619742,2.6913484429461025,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS280P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,280.0,252.6,1.9403519999999999,1.956,0.992,72.0,8.35,44.8,7.82,35.8,0.004759500000000001,-0.15500799999999998,45.4,1.8664621024905608,8.358721805972058,3.1085738756947717e-10,0.45567072688615207,436.2458186492464,4.752581672012737,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS280PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,280.0,252.5,1.9403519999999999,1.956,0.992,72.0,8.35,44.8,7.82,35.8,0.004759500000000001,-0.15814399999999998,45.4,1.8721014350984886,8.35855913368159,3.342235721202881e-10,0.454200197893793,443.10239427632337,3.2629877838670547,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,285.0,257.8,1.63,,,60.0,9.65,39.6,8.99,31.72,0.00579,-0.123156,48.4,1.573974331268131,9.668873832911148,1.1194800911028365e-10,0.35756794971357514,182.82088719747438,6.153006920475753,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,285.0,257.3,1.9403519999999999,1.956,0.992,72.0,8.38,45.3,7.86,36.25,0.0034358000000000006,-0.200679,45.4,1.8750369165475993,8.387698496675458,2.67011464838287e-10,0.4547125888338993,494.96577467312846,-19.14921838940605,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,285.0,257.3,1.9403519999999999,1.956,0.992,72.0,8.38,45.3,7.86,36.25,0.004106200000000001,-0.200679,45.3,1.8936831048704725,8.38718310864938,3.3891325220934076e-10,0.4498653471104268,524.8246848454073,-17.67559484895692,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,285.0,261.3,1.63,,,60.0,9.65,39.6,8.99,31.71,0.0049987,-0.12109680000000002,45.2,1.5676655937005792,9.669182243601407,1.011515392814321e-10,0.36027632171239166,181.24400496893645,7.195822766998968,-0.4083,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285P-20/U,Phono Solar Technology Co Ltd,Multi-c-Si,0,285.0,256.1,1.63,,,60.0,9.32,39.35,8.81,32.42,0.0063376000000000005,-0.140873,48.1,1.652559089404044,9.322167018334214,4.2308993181598677e-10,0.22994088828308656,988.939574621787,2.7034178787555017,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,285.0,257.2,1.9403519999999999,1.956,0.992,72.0,8.43,45.0,7.93,35.95,0.0048051000000000005,-0.1557,45.4,1.870160815312544,8.434696824974921,2.9729243678726455e-10,0.4548347287828201,816.3511308585054,4.28033487006977,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS285PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,285.0,257.1,1.9403519999999999,1.956,0.992,72.0,8.43,45.0,7.93,35.95,0.0048051000000000005,-0.15885,45.4,1.8757855341900516,8.43454524668023,3.1959119664434627e-10,0.45339000910698246,840.8959594119564,2.7962397168726847,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS290M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,290.0,262.5,1.63,,,60.0,9.71,39.7,9.1,31.87,0.0058260000000000004,-0.12346700000000001,48.4,1.5751231257974896,9.722410164088902,1.0841068353695848e-10,0.34711364927213056,271.58978591247615,5.804961912173004,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS290M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,290.0,261.9,1.9403519999999999,1.956,0.992,72.0,8.45,45.5,7.97,36.4,0.0034644999999999997,-0.20156500000000002,45.4,1.8773808086560162,8.452631975048742,2.5111479436373157e-10,0.4544779601771296,1459.110002001847,-19.616403773717135,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS290MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,290.0,262.0,1.9403519999999999,1.956,0.992,72.0,8.45,45.5,7.97,36.4,0.0041405,-0.20156500000000002,45.3,1.8959771729359531,8.452163584539388,3.1868230759875644e-10,0.4497167671408316,1756.3955589133163,-18.1526625311295,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS290MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,290.0,266.0,1.63,,,60.0,9.71,39.7,9.1,31.87,0.00502978,-0.12140260000000001,45.2,1.5690945906876144,9.722647863835862,9.838461954151716e-11,0.3484985883110446,267.54885968974077,6.881854001200091,-0.4083,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS290P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,290.0,261.8,1.9403519999999999,1.956,0.992,72.0,8.5,45.2,8.03,36.1,0.004845,-0.156392,45.4,1.8740466270768747,8.50071082415574,2.8465040179829553e-10,0.45449956198057967,5434.898020249064,3.8310760639619192,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS290PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,290.0,261.7,1.9403519999999999,1.956,0.992,72.0,8.5,45.2,8.03,36.1,0.004845,-0.159556,45.4,1.8796584851157325,8.50056996965013,3.059573122455289e-10,0.45307765572717895,6756.805464544329,2.3522254390020727,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS295M-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,295.0,267.2,1.63,,,60.0,9.74,39.8,9.2,32.07,0.005844,-0.12377799999999999,48.4,1.5761620556810092,9.744294814135035,1.0469434629019709e-10,0.331523548887746,751.8462479631338,5.454227254345166,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS295M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,295.0,266.5,1.9403519999999999,1.956,0.992,72.0,8.53,45.7,8.07,36.55,0.0034973,-0.20245100000000002,45.4,1.8827187368677518,8.530003870556344,2.4498515080203417e-10,0.4535585709080365,999991.1353215202,-19.844549954416735,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS295MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,295.0,266.6,1.9403519999999999,1.956,0.992,72.0,8.53,45.7,8.07,36.55,0.004179700000000001,-0.20245100000000002,45.3,1.9015369541251839,8.536047794183673,3.117255964755031e-10,0.4486522046029681,999999.8149450509,-18.370672285709865,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS295MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,295.0,270.7,1.63,,,60.0,9.74,39.8,9.2,32.07,0.00504532,-0.1217084,45.2,1.57013668719323,9.744492949365597,9.500562212832792e-11,0.332894452074145,721.6623583875679,6.52643657384584,-0.4083,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS295P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,295.0,262.2,1.9403519999999999,1.956,0.992,72.0,8.8,44.12,8.29,35.62,0.005544,-0.15927319999999998,48.7,1.8503120960686277,8.803757845861698,3.85989033726888e-10,0.3722997674304247,871.8398045500792,1.6218895729517673,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS295PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,295.0,266.4,1.9403519999999999,1.956,0.992,72.0,8.58,45.4,8.12,36.3,0.0048906,-0.160262,45.4,1.8883879760030453,8.58909462128033,3.1101447461540343e-10,0.44451561777007825,999999.9839518924,2.40022221930462,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 300P-24/TV,Phono Solar Technology Co Ltd,Multi-c-Si,0,300.0,268.7,1.9403519999999999,1.956,0.992,72.0,8.79,45.3,8.12,36.5,0.004395,-0.15402,46.3,1.9312242989664201,8.80987048509412,5.555043954999979e-10,0.38827252777321947,171.75806053572654,11.406343023896277,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS300M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,300.0,271.2,1.9403519999999999,1.956,0.992,72.0,8.6,45.9,8.17,36.7,0.003526,-0.20333700000000002,45.4,1.894540160331956,8.600003711384936,2.585950938195639e-10,0.43137249867742217,999999.6758437013,-19.54815011569811,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS300MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,300.0,271.3,1.9403519999999999,1.956,0.992,72.0,8.6,45.9,8.17,36.7,0.004214,-0.20333700000000002,45.3,1.9142855178854956,8.600003649437852,3.320096404604873e-10,0.4241321824726631,999999.95386497,-18.00466247141934,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS300MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,300.0,275.4,1.63,,,60.0,9.82,39.9,9.32,32.19,0.00508676,-0.12201420000000002,45.2,1.572274048265964,9.820332249075983,9.348479007836343e-11,0.3258402087048296,9630.596653697918,6.302124705372485,-0.4083,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS300P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,300.0,266.8,1.9403519999999999,1.956,0.992,72.0,8.85,44.49,8.33,36.04,0.0055755,-0.1606089,48.7,1.8703741178167161,8.854536771361772,4.107584331391022e-10,0.35603523793664277,694.5276103902079,2.091551811651537,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS300PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,300.0,271.0,1.9403519999999999,1.956,0.992,72.0,8.65,45.6,8.24,36.4,0.004930500000000001,-0.160968,45.4,1.9022209009572888,8.650003570686552,3.358270551048064e-10,0.4125813273365721,999999.6064100472,2.9773756093405837,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 305P-24/TV,Phono Solar Technology Co Ltd,Multi-c-Si,0,305.0,273.3,1.9403519999999999,1.956,0.992,72.0,9.05,45.6,8.16,37.4,0.004525,-0.15504,46.3,1.9926107585841355,9.080818455638699,9.821279544837482e-10,0.28044263369973244,82.35344667905824,16.49079643717363,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS305M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,305.0,275.8,1.9403519999999999,1.956,0.992,72.0,8.68,46.1,8.26,36.9,0.0035588000000000004,-0.20422300000000002,45.4,1.9053905234229933,8.680003605216939,2.697572657449594e-10,0.4151725684826558,999999.8624524839,-19.334324108610605,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS305MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,305.0,275.9,1.9403519999999999,1.956,0.992,72.0,8.68,46.1,8.26,36.9,0.0042532,-0.20422300000000002,45.3,1.925294130996205,8.6800035421858,3.4641739256628405e-10,0.4078747287011397,999999.8615167319,-17.7848265734669,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS305MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,305.0,280.2,1.63,,,60.0,9.87,40.0,9.43,32.36,0.00511266,-0.12232000000000001,45.2,1.5824732052807393,9.870002844968594,1.0392068084534897e-10,0.2881906819555627,999998.8241245801,7.167628718286599,-0.4083,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS305P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,305.0,271.4,1.9403519999999999,1.956,0.992,72.0,8.9,44.87,8.37,36.45,0.005607000000000001,-0.16198069999999998,48.7,1.8903190691764227,8.905220504311762,4.336596890415409e-10,0.34255973462974365,584.0015587521711,2.4976614582809034,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS305PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,305.0,275.6,1.9403519999999999,1.956,0.992,72.0,8.73,45.7,8.36,36.5,0.004976100000000001,-0.161321,45.4,1.9123870382852293,8.73028185881181,3.6523183901156365e-10,0.3755363465546374,11631.538372777632,3.602006641780579,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 310M-24/TV,Phono Solar Technology Co Ltd,Mono-c-Si,0,310.0,276.9,1.9403519999999999,1.956,0.992,72.0,9.0,46.1,8.33,37.2,0.0036,-0.16135,46.5,1.9705060307287123,9.018237896731229,6.063092180541528e-10,0.3768323961398306,185.9585089567973,8.873113334179548,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 310P-24/TV,Phono Solar Technology Co Ltd,Multi-c-Si,0,310.0,277.9,1.9403519999999999,1.956,0.992,72.0,9.08,45.8,8.22,37.7,0.004540000000000001,-0.15572,46.3,2.000960655570135,9.106653631611058,9.85401332135993e-10,0.2621132921301042,89.29323134412456,16.478512977104412,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS310M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,310.0,280.5,1.9403519999999999,1.956,0.992,72.0,8.75,46.3,8.36,37.1,0.0035875000000000004,-0.20510899999999999,45.4,1.918435607092302,8.75000338441208,2.8882537988782895e-10,0.38662947982672774,999997.5155824092,-18.942297350158803,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS310MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,310.0,280.6,1.9403519999999999,1.956,0.992,72.0,8.75,46.3,8.36,37.1,0.0042875000000000005,-0.20510899999999999,45.3,1.9385677759764155,8.750003600572734,3.710948890450895e-10,0.37913654197306396,921768.8581505964,-17.38102325343274,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS310MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,310.0,284.9,1.63,,,60.0,9.92,40.1,9.54,32.5,0.0051385599999999995,-0.12262580000000001,45.2,1.5929313833942225,9.920226517678284,1.157594177590646e-10,0.25070960083100446,10979.469672788107,8.060675579792,-0.4083,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS310MH-20/UH,Phono Solar Technology Co Ltd,Mono-c-Si,0,310.0,288.0,1.661,,,60.0,9.67,39.9,9.22,33.63,0.0043515,-0.11251799999999999,44.28,1.5292387531362883,9.67053481850807,4.5029915182693535e-11,0.167336975948912,3025.6036191158328,8.963045869702011,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS310P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,310.0,276.0,1.9403519999999999,1.956,0.992,72.0,8.95,45.24,8.41,36.87,0.005638499999999999,-0.1633164,48.7,1.9104087117773403,8.955812076826621,4.6055491498770753e-10,0.32658877449609247,502.91323686814127,2.955150567229523,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS310PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,310.0,280.3,1.9403519999999999,1.956,0.992,72.0,8.8,46.0,8.45,36.7,0.0050160000000000005,-0.16238,45.4,1.9264804615949442,8.800274212985634,3.752586661511899e-10,0.3634780662622509,11664.748730191463,3.76195229359785,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 315M-24/TV,Phono Solar Technology Co Ltd,Mono-c-Si,0,315.0,281.5,1.9403519999999999,1.956,0.992,72.0,9.05,46.1,8.38,37.6,0.0036200000000000004,-0.16135,46.5,1.982614789299512,9.065810106339823,7.028125362832422e-10,0.3181472334156508,182.11344154868434,10.133367288543992,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 315P-24/TV,Phono Solar Technology Co Ltd,Multi-c-Si,0,315.0,282.5,1.9403519999999999,1.956,0.992,72.0,9.17,45.9,8.31,37.9,0.0045850000000000005,-0.15606,46.3,2.007906794353853,9.194717223298284,1.0257621111543434e-09,0.24355226269310645,90.35701183512025,16.762959171705248,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS315M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,315.0,283.7,1.94,,,72.0,9.32,46.8,8.55,36.99,0.0041008,-0.14976,48.8,1.8378950001888616,9.359552977754715,7.834831438250957e-11,0.5118722301045684,120.61416289302993,0.7504194776169905,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS315MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,315.0,285.2,1.9403519999999999,1.956,0.992,72.0,8.83,46.5,8.45,37.25,0.0043267,-0.205995,45.3,1.9482486997533481,8.830003263608862,3.805364014473243e-10,0.36936535816398025,999857.8840095813,-17.274232612428346,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS315MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,315.0,289.6,1.63,,,60.0,9.98,40.2,9.64,32.68,0.00516964,-0.12293160000000002,45.2,1.6023512463855893,9.980195904427108,1.2686545196599412e-10,0.21697255555805092,11053.298343434062,8.808577112942952,-0.4083,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS315MH-20/UH,Phono Solar Technology Co Ltd,Mono-c-Si,0,315.0,292.7,1.661,,,60.0,9.76,40.11,9.31,33.84,0.004392,-0.1131102,44.28,1.5377187207733651,9.760351052946879,4.5802841389652525e-11,0.1626595497798053,4522.273902697716,9.029582097710994,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS315P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,315.0,280.6,1.9403519999999999,1.956,0.992,72.0,9.01,45.59,8.45,37.28,0.0056763000000000004,-0.1645799,48.7,1.9310331546895096,9.017074379105006,4.967549754218895e-10,0.30922999273463364,393.8385016693179,3.5392542938537273,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS315PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,315.0,284.9,1.9403519999999999,1.956,0.992,72.0,8.88,46.2,8.55,36.85,0.0050616,-0.163086,45.4,1.937166966078517,8.88026288932652,3.896097949396966e-10,0.34551905561443363,11671.17283160134,4.000968637627944,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 320M-24/TV,Phono Solar Technology Co Ltd,Mono-c-Si,0,320.0,286.1,1.9403519999999999,1.956,0.992,72.0,9.08,46.3,8.46,37.8,0.0036320000000000002,-0.16204999999999997,46.5,1.9854761472289872,9.091379025002372,6.641397393276517e-10,0.3143498943363624,250.83850107721133,9.579012039334511,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 320P-24/TV,Phono Solar Technology Co Ltd,Multi-c-Si,0,320.0,287.1,1.9403519999999999,1.956,0.992,72.0,9.2,46.2,8.33,38.4,0.0046,-0.15708000000000003,46.3,2.0302338386673457,9.221623927691468,1.1394703950475124e-09,0.20808643133463164,88.53134147162596,17.739212066546624,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS320M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,320.0,288.4,1.94,,,72.0,9.37,46.92,8.64,37.18,0.004122799999999999,-0.150144,48.8,1.84043942140371,9.402815283103964,7.688592811311896e-11,0.4969986416456602,141.91184631197933,0.5381761362393157,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS320MB-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,320.0,289.9,1.9403519999999999,1.956,0.992,72.0,8.9,46.7,8.55,37.4,0.004361,-0.206881,45.3,1.9609144604970183,8.900260806504967,4.0392726591538773e-10,0.34358528996850296,11724.88705980122,-16.927318583742704,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS320MH-20/U,Phono Solar Technology Co Ltd,Mono-c-Si,0,320.0,294.4,1.63,,,60.0,10.06,40.3,9.75,32.83,0.005211080000000001,-0.1232374,45.2,1.6103137014470887,10.060145783847906,1.3606296718942475e-10,0.19014902987273094,13121.424635828436,9.353478865724268,-0.4083,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS320MH-20/UH,Phono Solar Technology Co Ltd,Mono-c-Si,0,320.0,297.5,1.661,,,60.0,9.85,40.35,9.39,34.08,0.0044325,-0.113787,44.28,1.5482789045459395,9.850671795080515,4.7256428276772125e-11,0.1574354867753396,2308.352319951699,9.226937888872142,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS320P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,320.0,285.2,1.94,,,72.0,9.03,46.04,8.49,37.7,0.005688899999999999,-0.16620439999999997,48.7,1.9490045774212135,9.035315920509928,4.927267612402355e-10,0.30474288292891577,517.6580459470433,3.4445494047031944,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS320PB-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,320.0,289.6,1.9403519999999999,1.956,0.992,72.0,8.95,46.4,8.64,37.0,0.0051015,-0.163792,45.4,1.9471127024929524,8.950002955716709,4.0041980596124933e-10,0.33008750092855005,999997.3092832715,4.163859031915845,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS 325M-24/TV,Phono Solar Technology Co Ltd,Mono-c-Si,0,325.0,290.7,1.9403519999999999,1.956,0.992,72.0,9.11,46.55,8.55,37.98,0.003644,-0.162925,46.5,1.9874685434292512,9.116331906576965,6.067786266664838e-10,0.31950338190455174,459.68409377461205,8.726059930365356,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 325P-24/TV,Phono Solar Technology Co Ltd,Multi-c-Si,0,325.0,291.8,1.9403519999999999,1.956,0.992,72.0,9.25,46.4,8.37,38.8,0.004625,-0.15776,46.3,2.0473488667410753,9.268566993752653,1.2549783584769248e-09,0.17446815777803787,86.91932640217621,18.619767635299112,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS325M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,325.0,293.0,1.94,,,72.0,9.43,47.04,8.72,37.36,0.0041492,-0.150528,48.8,1.8448456150915253,9.459115066957164,7.729689463598625e-11,0.48340580465027505,156.56899827725613,0.5209193435198689,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS325MH-20/UH,Phono Solar Technology Co Ltd,Mono-c-Si,0,325.0,302.3,1.661,,,60.0,9.94,40.57,9.48,34.29,0.0044729999999999995,-0.11440739999999999,44.28,1.5569443729545531,9.940488224234695,4.788895117510538e-11,0.15400076247188915,3135.380793231954,9.262231168102034,-0.373,N,2025.7.3,6/23/2025,4.0,bootstrapping +Phono Solar Technology Co Ltd PS325P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,325.0,289.8,1.94,,,72.0,9.11,46.34,8.53,38.11,0.0057393,-0.1672874,48.7,1.9711736557182766,9.117761839836222,5.53829494839149e-10,0.28061370847018896,329.353790179981,4.369263044451744,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 330M-24/TV,Phono Solar Technology Co Ltd,Mono-c-Si,0,330.0,295.4,1.9403519999999999,1.956,0.992,72.0,9.15,46.84,8.61,38.31,0.0036600000000000005,-0.16394,46.5,1.9998525846391186,9.154451588880478,6.111918907020956e-10,0.3076580001077995,632.3746350857837,8.742161095482066,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS330M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,330.0,297.7,1.94,,,72.0,9.48,47.16,8.81,37.55,0.0041712,-0.150912,48.8,1.8474945936529192,9.502987628209636,7.595772518920467e-11,0.4690789376854998,193.44616317594728,0.32060948662965383,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS330P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,330.0,294.4,1.94,,,72.0,9.15,46.74,8.57,38.53,0.0057645000000000005,-0.1687314,48.7,1.9906394784729122,9.157384134904625,5.726515165955223e-10,0.26932124738510627,333.72763543994824,4.614877620859338,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS 335M-24/TV,Phono Solar Technology Co Ltd,Mono-c-Si,0,335.0,300.0,1.9403519999999999,1.956,0.992,72.0,9.18,46.99,8.7,38.49,0.003672,-0.164465,46.5,2.001476660063637,9.180003328194703,5.842779318254614e-10,0.30068929762084834,829809.7624914033,8.294291059006584,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS335M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,335.0,302.3,1.94,,,72.0,9.54,47.28,8.89,37.73,0.0041976,-0.151296,48.8,1.8519580433637595,9.559697110121922,7.641601162167162e-11,0.455984154177833,220.8490972870021,0.3095439216029185,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS335P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,335.0,299.0,1.94,,,72.0,9.2,47.12,8.61,38.94,0.005796,-0.1701032,48.7,2.010664567695542,9.20761824644822,6.014616207205846e-10,0.2566095969264852,309.8887289077615,4.988942805353463,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS340M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,340.0,307.0,1.94,,,72.0,9.59,47.4,8.98,37.91,0.0042196,-0.15168,48.8,1.8544327328939396,9.604162587151775,7.490863026768135e-11,0.44348061136839184,300.2967761334127,0.0902869547409796,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS340P-24/T,Phono Solar Technology Co Ltd,Multi-c-Si,0,340.0,303.6,1.94,,,72.0,9.25,47.49,8.65,39.36,0.0058275,-0.1714389,48.7,2.030833037706429,9.257729541902677,6.352863633936311e-10,0.24146826264463178,288.9669045940178,5.4128798662807105,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS345M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,345.0,311.6,1.94,,,72.0,9.65,47.52,9.06,38.1,0.004246,-0.15206400000000003,48.8,1.8592194746137884,9.66124070900256,7.568671896331107e-11,0.429552614473497,368.76525851284254,0.11478633262011241,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS345MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,345.0,316.3,1.94,,,72.0,9.65,47.52,9.06,38.1,0.00597335,-0.15600816,45.3,1.900589711569518,9.659909839633807,1.3217661914881168e-10,0.42002191790575183,409.0088236038245,1.8221378949482596,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS350M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,350.0,316.3,1.94,,,72.0,9.71,47.64,9.15,38.26,0.0042724,-0.152448,48.8,1.8622057134304628,9.717320352460431,7.470292970405156e-11,0.4196721365745932,556.6694769831472,-0.05326143453424589,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS350M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,350.0,326.4,1.8,,,40.0,11.06,40.06,10.54,33.21,0.00543046,-0.10631924000000001,45.09,1.4767063427116784,11.061264728629126,1.825832652063964e-11,0.2170402802545202,1898.0075740769214,6.453880594831206,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS350MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,350.0,321.0,1.94,,,72.0,9.71,47.64,9.15,38.26,0.00601049,-0.15640211999999998,45.3,1.9036169384663437,9.716088707900008,1.3048232089553755e-10,0.41022074900864525,654.2018493083242,1.6533810934974236,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS350MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,350.0,320.5,1.98,,,144.0,9.4,46.4,9.03,38.77,0.0046436,-0.15813119999999997,44.8,1.9058546071767177,9.400001524769477,2.5106015961123297e-10,0.1621752535538217,999990.5079956357,3.606845256630263,-0.4235,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS355M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,355.0,321.0,1.94,,,72.0,9.74,47.76,9.22,38.51,0.0042856,-0.152832,48.8,1.866784410754593,9.742751834129619,7.518667397544456e-11,0.3998014426771604,1415.080494898188,-0.04135550639990681,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS355M4-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.06,40.48,10.61,33.71,0.0054194,-0.10779823999999999,44.8,1.4987579291574804,11.06000205478101,2.0600620927356774e-11,0.18577814230681194,999993.110905529,7.1304385272989865,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS355M4H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.06,40.48,10.61,33.71,0.0054194,-0.10779823999999999,44.8,1.4987579291574804,11.06000205478101,2.0600620927356774e-11,0.18577814230681194,999993.110905529,7.1304385272989865,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS355M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,355.0,331.2,1.8,,,40.0,11.14,40.34,10.61,33.46,0.005469740000000001,-0.10706236000000002,45.09,1.4878321406941775,11.141781526953494,1.86482660274491e-11,0.21502313551751737,1344.5532181442047,6.577040419038941,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS355MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,355.0,325.7,1.94,,,72.0,9.74,47.76,9.22,38.51,0.006029059999999999,-0.15679607999999998,45.3,1.9083173185384792,9.741672376576773,1.313664764480439e-10,0.39037369460754173,2273.5544630787076,1.669290942281727,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS355MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,355.0,325.2,1.98,,,144.0,9.47,46.66,9.1,39.02,0.0046781800000000005,-0.15901727999999998,44.8,1.9175765469036825,9.470001480561743,2.5630001531090333e-10,0.15629594546259745,999904.8563143224,3.717412353875503,-0.4235,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS360M-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,360.0,325.6,1.94,,,72.0,9.82,47.88,9.32,38.63,0.0043208000000000005,-0.15321600000000002,48.8,1.8696895100467013,9.820157229005384,7.419749119798238e-11,0.3945804729094232,24644.26303976626,-0.223065374930795,-0.405,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS360M4-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,360.0,336.1,1.82,,,60.0,11.15,40.69,10.68,32.99,0.0054635000000000005,-0.10835746999999998,44.8,1.488544329404404,11.150003118048717,1.4984656629050553e-11,0.2796331247740773,999989.5303659611,4.32821882862111,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS360M4H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,360.0,336.1,1.82,,,60.0,11.15,40.69,10.68,32.99,0.0054635000000000005,-0.10835746999999998,44.8,1.488544329404404,11.150003118048717,1.4984656629050553e-11,0.2796331247740773,999989.5303659611,4.32821882862111,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS360M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,360.0,335.9,1.8,,,40.0,11.22,40.62,10.68,33.71,0.00550902,-0.10780548000000001,45.09,1.498968065463989,11.222288103482505,1.9045088540739375e-11,0.21303011224330162,1044.6196787109063,6.700080490022708,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS360MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,360.0,330.4,1.94,,,72.0,9.82,47.88,9.32,38.63,0.00607858,-0.15719004,45.3,1.9128037882966786,9.820004835369192,1.3217389483632823e-10,0.38493901091636323,781893.4329153965,1.646631121412217,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS360MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,360.0,329.9,1.98,,,144.0,9.55,46.92,9.16,39.31,0.004717700000000001,-0.15990336,44.8,1.9282552128999495,9.55000150471038,2.584439694020186e-10,0.1575290709029087,999998.4926040593,3.7167269226060564,-0.4235,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS365M4-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,365.0,340.9,1.82,,,60.0,11.23,40.81,10.75,33.96,0.005502700000000001,-0.10867703,44.8,1.5090070587823987,11.230003617708219,2.0192892615247142e-11,0.2033334212869249,631194.9720581889,6.824584133238124,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS365M4H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,365.0,340.9,1.82,,,60.0,11.23,40.81,10.75,33.96,0.005502700000000001,-0.10867703,44.8,1.5090070587823987,11.230003617708219,2.0192892615247142e-11,0.2033334212869249,631194.9720581889,6.824584133238124,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS365M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,365.0,340.7,1.8,,,40.0,11.3,40.9,10.75,33.96,0.0055483,-0.10854860000000001,45.09,1.5101013266462466,11.302784900520662,1.944443215740935e-11,0.2110633609625658,856.4097802453692,6.821013118345156,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS365MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,365.0,335.1,1.94,,,72.0,9.87,48.0,9.4,38.83,0.006109529999999999,-0.15758399999999997,45.3,1.9231321524104343,9.870003481303197,1.4276976115382186e-10,0.352641646541093,999999.9388570961,2.2393911981651544,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS365MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,365.0,334.6,1.98,,,144.0,9.63,47.19,9.22,39.59,0.00475722,-0.16082352,44.8,1.9389236691901421,9.630001545760157,2.592140684452096e-10,0.16048219950879747,999999.7191542427,3.671884311229392,-0.4235,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS370M4-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,370.0,345.7,1.82,,,60.0,11.31,40.97,10.82,34.2,0.005541900000000001,-0.10910310999999999,44.8,1.5165880514268355,11.310003504613864,2.0949520575689586e-11,0.1915248694594111,618095.8665434225,7.082160931148101,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS370M4H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,370.0,345.7,1.82,,,60.0,11.31,40.97,10.82,34.2,0.005541900000000001,-0.10910310999999999,44.8,1.5165880514268355,11.310003504613864,2.0949520575689586e-11,0.1915248694594111,618095.8665434225,7.082160931148101,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS370M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,370.0,345.5,1.8,,,40.0,11.38,41.16,10.82,34.2,0.00558758,-0.10923864,45.09,1.520644743033084,11.383273425667626,1.9899503649298425e-11,0.20831774079753704,724.2125176016596,6.963220233829779,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS370MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,370.0,339.9,1.94,,,72.0,9.92,48.12,9.49,39.02,0.006140479999999999,-0.15797795999999997,45.3,1.9341416216065912,9.920003167405662,1.554487126782673e-10,0.31922928541501505,999997.669408018,2.901986782551216,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS370MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,370.0,339.3,1.98,,,144.0,9.71,47.44,9.29,39.83,0.00479674,-0.16167552,44.8,1.9492392744153932,9.710001555522048,2.615101314119625e-10,0.16016501453531518,999999.8496346882,3.676443271231348,-0.4235,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS375M4-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,375.0,350.5,1.82,,,60.0,11.4,41.18,10.89,34.44,0.005586000000000001,-0.10966234,44.8,1.5246926624771036,11.40000347803497,2.1240441234070754e-11,0.18445632450128793,604605.8417115383,7.133117975458124,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS375M4H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,375.0,350.5,1.82,,,60.0,11.4,41.18,10.89,34.44,0.005586000000000001,-0.10966234,44.8,1.5246926624771036,11.40000347803497,2.1240441234070754e-11,0.18445632450128793,604605.8417115383,7.133117975458124,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS375M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,375.0,350.3,1.8,,,40.0,11.46,41.43,10.89,34.44,0.00562686,-0.10995522,45.09,1.5313732417766512,11.463749380548226,2.0293901989614733e-11,0.20653376336428628,631.271469605106,7.075416089026748,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS375MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,375.0,344.6,1.94,,,72.0,9.98,48.24,9.57,39.19,0.00617762,-0.15837192,45.3,1.9428160505289362,9.98000316674996,1.642948106617354e-10,0.2975957337876666,937169.3827156115,3.312440876456806,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS375MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,375.0,344.1,1.98,,,144.0,9.79,47.69,9.35,40.11,0.004836259999999999,-0.16252751999999998,44.8,1.9594887641164849,9.790001571782321,2.635905679587617e-10,0.16051621457666465,999999.8964402652,3.674094226312978,-0.4235,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS380M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,354.7,2.01,,,48.0,10.05,48.57,9.52,39.92,0.00459285,-0.13473318,43.5,1.8285188190906287,10.054918965178434,2.9055820141049625e-11,0.32148933457186246,656.838935687152,6.60994498345495,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS380M1-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,355.6,2.01,,,48.0,10.05,48.57,9.52,39.92,0.00517575,-0.13483032,43.2,1.825267368320282,10.054993941124717,2.7710557572908755e-11,0.3222313023484794,648.4707355357004,6.049662417352172,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS380M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,354.7,2.01,,,48.0,10.05,48.57,9.52,39.92,0.00459285,-0.13473318,43.5,1.8285188190906287,10.054918965178434,2.9055820141049625e-11,0.32148933457186246,656.838935687152,6.60994498345495,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS380M1H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,355.6,2.01,,,48.0,10.05,48.57,9.52,39.92,0.00517575,-0.13483032,43.2,1.825267368320282,10.054993941124717,2.7710557572908755e-11,0.3222313023484794,648.4707355357004,6.049662417352172,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS380M5H-20/UHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,355.1,1.8,,,40.0,11.54,41.69,10.96,34.68,0.005666139999999999,-0.11064526000000001,45.09,1.541919038658958,11.544213949319413,2.075898963188552e-11,0.20385137412234766,558.2518252075184,7.214581912895671,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS380MH-24/T,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,349.3,1.94,,,72.0,10.03,48.36,9.66,39.39,0.00620857,-0.15876588,45.3,1.954723266749416,10.030222957286856,1.805730274555429e-10,0.2590695211540299,11654.57800369198,4.062544411267762,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS380MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,380.0,348.8,1.98,,,144.0,9.87,47.94,9.42,40.35,0.00487578,-0.16337952,44.8,1.969714980858059,9.870002512271517,2.655936237526914e-10,0.1731874779115099,680503.7284827554,3.6693562568925424,-0.4235,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS385M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,385.0,359.5,2.01,,,48.0,10.13,48.85,9.57,40.24,0.0046294100000000005,-0.13550990000000002,43.5,1.8435825168781592,10.137116905213496,3.1153115123853726e-11,0.30980343407842836,440.96538514539577,7.155820251906305,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS385M1-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,385.0,360.4,2.01,,,48.0,10.13,48.85,9.57,40.24,0.005216950000000001,-0.13560760000000002,43.2,1.8403020786727131,10.137195376305636,2.971328273404175e-11,0.3105497944619982,437.20707926720934,6.593939376486986,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS385M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,385.0,359.5,2.01,,,48.0,10.13,48.85,9.57,40.24,0.0046294100000000005,-0.13550990000000002,43.5,1.8435825168781592,10.137116905213496,3.1153115123853726e-11,0.30980343407842836,440.96538514539577,7.155820251906305,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS385M1H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,385.0,360.4,2.01,,,48.0,10.13,48.85,9.57,40.24,0.005216950000000001,-0.13560760000000002,43.2,1.8403020786727131,10.137195376305636,2.971328273404175e-11,0.3105497944619982,437.20707926720934,6.593939376486986,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS385MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,385.0,353.5,1.98,,,144.0,9.95,48.19,9.48,40.62,0.004915299999999999,-0.16423152,44.8,1.9798095370540705,9.950002480827981,2.671636451460836e-10,0.16569209668589455,664643.8762953185,3.6511582574608346,-0.4235,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,364.3,2.01,,,48.0,10.21,49.13,9.62,40.55,0.00466597,-0.13628662,43.5,1.8584419594482342,10.219159404378896,3.326992502120886e-11,0.29942653624290844,333.7711553062958,7.670158885531229,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M1-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,365.1,2.01,,,48.0,10.2,49.12,9.62,40.55,0.005252999999999999,-0.13635712,43.2,1.8540621047543426,10.208445827817403,3.142691818980354e-11,0.2994955764862561,361.69988233774166,7.026826692641025,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,364.3,2.01,,,48.0,10.21,49.13,9.62,40.55,0.00466597,-0.13628662,43.5,1.8584419594482342,10.219159404378896,3.326992502120886e-11,0.29942653624290844,333.7711553062958,7.670158885531229,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M1H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,365.1,2.01,,,48.0,10.2,49.12,9.62,40.55,0.005252999999999999,-0.13635712,43.2,1.8540621047543426,10.208445827817403,3.142691818980354e-11,0.2994955764862561,361.69988233774166,7.026826692641025,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M6H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,364.1,1.9,,,36.0,13.32,36.48,12.79,30.5,0.007192800000000001,-0.0995904,44.49,1.3789653390665475,13.320068551856277,4.3188400163426515e-11,0.13565052938423058,26357.683278529825,9.2161478187481,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M8GFH-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,362.4,1.9,,,36.0,13.61,36.19,12.97,30.08,0.0050357,-0.09771300000000001,44.47,1.3747545532814798,13.610517295747327,5.0222919369807566e-11,0.14581779214902574,3836.4525151822895,11.819010944266507,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,364.6,1.9,,,36.0,13.32,36.48,12.79,30.5,0.006273720000000001,-0.09488448,44.77,1.3455515535552645,13.390015590971188,2.250955737133317e-11,0.1408011253510572,85957.39051481654,8.821608194111016,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS390MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,390.0,358.3,1.98,,,144.0,10.02,48.5,9.53,40.93,0.00494988,-0.165288,44.8,1.9920857373226368,10.02000335993172,2.6753562329993745e-10,0.15994617471725142,477038.9693554876,3.6042464770285707,-0.4235,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,369.0,2.01,,,48.0,10.29,49.41,9.67,40.85,0.004702529999999999,-0.13706333999999998,43.5,1.873093749295919,10.301079490779632,3.539261110647507e-11,0.2903392191223751,269.65053373636647,8.153081438100358,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,369.0,2.01,,,48.0,10.29,49.41,9.67,40.85,0.004702529999999999,-0.13706333999999998,43.5,1.873093749295919,10.301079490779632,3.539261110647507e-11,0.2903392191223751,269.65053373636647,8.153081438100358,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395M6H-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,368.9,1.9,,,36.0,13.42,36.67,12.88,30.67,0.0072468,-0.10010910000000002,44.49,1.3866671357709848,13.420440193033313,4.392264286340484e-11,0.13431899867521538,4094.9340536133327,9.301067024125732,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395M6H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,368.9,1.9,,,36.0,13.42,36.67,12.88,30.67,0.0072468,-0.10010910000000002,44.49,1.3866671357709848,13.420440193033313,4.392264286340484e-11,0.13431899867521538,4094.9340536133327,9.301067024125732,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395M8GFH-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,367.2,1.9,,,36.0,13.69,36.42,13.04,30.3,0.005065299999999999,-0.09833400000000002,44.47,1.3829867260498654,13.69000429756582,5.006750010109364e-11,0.14354050422870787,457268.4844780285,11.73570073085274,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,369.3,1.9,,,36.0,13.42,36.67,12.88,30.67,0.006320820000000001,-0.09537867000000001,44.77,1.3563069663582996,13.420454995524848,2.4300195350522456e-11,0.13948876415172629,4114.193239654875,9.478624360196083,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS395MH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,395.0,363.0,1.98,,,144.0,10.1,48.73,9.6,41.15,0.0049894,-0.16607183999999997,44.8,2.0045108477431803,10.100593056021276,2.7911529436174924e-10,0.15578793754058934,2653.1370073412622,3.8977375578605638,-0.4235,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS400M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,400.0,373.8,2.01,,,48.0,10.37,49.69,9.72,41.16,0.00473909,-0.13784006,43.5,1.8880153236030435,10.382824055330385,3.775731510775037e-11,0.2801434283423022,226.53422091179678,8.663302315811407,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS400M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,400.0,373.8,2.01,,,48.0,10.37,49.69,9.72,41.16,0.00473909,-0.13784006,43.5,1.8880153236030435,10.382824055330385,3.775731510775037e-11,0.2801434283423022,226.53422091179678,8.663302315811407,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS400M6H-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,400.0,373.7,1.9,,,36.0,13.52,36.87,12.97,30.85,0.007300799999999999,-0.1006551,44.49,1.3822697299387996,13.520003311359687,3.522182672482296e-11,0.13499169310419246,551175.6945362048,7.297616283696938,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS400M6H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS400M8GFH-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,400.0,372.0,1.9,,,36.0,13.78,36.63,13.11,30.51,0.0050986,-0.09890100000000002,44.47,1.3663884847747914,13.783016511763954,3.1266045105043754e-11,0.1446547823854769,660.8106069046136,7.5271908273125545,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS400M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,400.0,374.1,1.9,,,36.0,13.52,36.87,12.97,30.85,0.00636792,-0.09589887,44.77,1.363124531034084,13.520052821151273,2.4214839773634857e-11,0.13823799522679803,35383.17427666666,9.379333389795933,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS405M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,405.0,378.6,2.01,,,48.0,10.45,49.97,9.77,41.46,0.004775649999999999,-0.13861678,43.5,1.9027265722529956,10.464469901543243,4.012554624347998e-11,0.27122290606448246,195.8741313410361,9.142183062272563,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS405M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,405.0,378.6,2.01,,,48.0,10.45,49.97,9.77,41.46,0.004775649999999999,-0.13861678,43.5,1.9027265722529956,10.464469901543243,4.012554624347998e-11,0.27122290606448246,195.8741313410361,9.142183062272563,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS405M6H-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,405.0,378.5,1.9,,,36.0,13.62,37.05,13.06,31.02,0.007354799999999999,-0.1011465,44.49,1.2413402944631944,13.620002542288336,1.4855513699571445e-12,0.15837380621321434,848469.4939605166,-17.337578282203125,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS405M6H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS405M8GFH-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,405.0,376.8,1.9,,,36.0,13.86,36.87,13.18,30.73,0.005128199999999999,-0.099549,44.47,1.404022462839629,13.862612944417993,5.4397689421035066e-11,0.13833102276314954,733.757750313985,12.387102001920178,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS405M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,405.0,379.0,1.9,,,36.0,13.62,37.05,13.06,31.02,0.00641502,-0.09636705,44.77,1.352222360230577,13.620003472582951,1.7170895721997276e-11,0.13924710264695764,546156.6541642499,6.304279509560876,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS410M1-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,410.0,383.4,2.01,,,48.0,10.53,50.25,9.82,41.76,0.004812209999999999,-0.1393935,43.5,1.9174685245180574,10.545985986165027,4.262249828411953e-11,0.26238068023826444,172.83066294065947,9.619294773964588,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS410M1H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,410.0,383.4,2.01,,,48.0,10.53,50.25,9.82,41.76,0.004812209999999999,-0.1393935,43.5,1.9174685245180574,10.545985986165027,4.262249828411953e-11,0.26238068023826444,172.83066294065947,9.619294773964588,-0.3658,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS410M6H-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,410.0,383.3,1.9,,,36.0,13.72,37.23,13.15,31.18,0.007408800000000001,-0.1016379,44.49,1.389038573675204,13.720003368258453,3.1411045140878946e-11,0.13306115762860227,542014.6500800863,6.179885792399408,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS410M6H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS410M8GFH-18/VH,Phono Solar Technology Co Ltd,Mono-c-Si,0,410.0,381.6,1.9,,,36.0,13.95,37.09,13.25,30.95,0.005161499999999999,-0.10014300000000002,44.47,1.4140692988237953,13.953677250683864,5.63901147627142e-11,0.13498818511483332,512.0905330496458,12.660557090425808,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS410M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,410.0,383.8,1.9,,,36.0,13.72,37.23,13.15,31.18,0.006462120000000001,-0.09683523,44.77,1.3560520117697157,13.720003509221446,1.6365440872702955e-11,0.13860429775321012,541908.8465080371,5.826718151750033,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS415M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,415.0,388.6,1.9,,,36.0,13.82,37.42,13.24,31.35,0.006509220000000001,-0.09732942000000001,44.77,1.3604048457917584,13.820003541431927,1.5652261869307576e-11,0.13784698668756445,537938.0803197861,5.3814545038482064,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS420M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,420.0,399.2,1.94,,,18.0,13.42,39.4,12.84,32.7,0.0059048,-0.08865,43.1,1.3478761416329723,13.420649117667525,2.7071537457181823e-12,0.19059689189975068,3940.4413080095574,5.8839009109804685,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS420M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,420.0,399.2,1.94,,,18.0,13.42,39.4,12.84,32.7,0.0059048,-0.08865,43.1,1.3478761416329723,13.420649117667525,2.7071537457181823e-12,0.19059689189975068,3940.4413080095574,5.8839009109804685,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS420M8H-18/VHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,420.0,393.4,1.9,,,36.0,13.92,37.61,13.33,31.52,0.00655632,-0.09782360999999999,44.77,1.3649665316768198,13.920003570986681,1.5037601458907944e-11,0.13706604729829253,534301.5879591119,4.976734041679082,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS425M4-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,425.0,396.5,2.22,,,48.0,10.95,48.59,10.52,40.4,0.0053655000000000005,-0.12939517,44.8,1.7989632930379877,10.950002462831911,2.0375955437718592e-11,0.2249085510255922,999990.4404955186,7.1220114655286775,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS425M4H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,425.0,396.5,2.22,,,48.0,10.95,48.59,10.52,40.4,0.0053655000000000005,-0.12939517,44.8,1.7989632930379877,10.950002462831911,2.0375955437718592e-11,0.2249085510255922,999990.4404955186,7.1220114655286775,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS425M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,425.0,396.7,2.1,,,48.0,11.04,48.73,10.52,40.4,0.00542064,-0.12932942,45.09,1.7964361010858898,11.041338707466947,1.825994343721726e-11,0.2642112332779772,2178.8869077493664,6.470700773343608,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS425M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,425.0,404.0,1.94,,,18.0,13.51,39.6,12.92,32.9,0.0059444,-0.08910000000000001,43.1,1.355631426127221,13.511237329672822,2.7777153438865393e-12,0.1872990091129002,2045.0569406095008,6.053940046929555,-0.293,N,2025.7.3,6/23/2025,4.0,bootstrapping +Phono Solar Technology Co Ltd PS425M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,425.0,404.0,1.94,,,18.0,13.51,39.6,12.92,32.9,0.0059444,-0.08910000000000001,43.1,1.355631426127221,13.511237329672822,2.7777153438865393e-12,0.1872990091129002,2045.0569406095008,6.053940046929555,-0.293,N,2025.7.3,6/23/2025,4.0,bootstrapping +Phono Solar Technology Co Ltd PS430M4-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,400.4,2.22,,,48.0,11.04,48.72,10.59,40.61,0.00521088,-0.13271328,45.0,1.8189624204961012,11.04000423343902,2.5739809408992726e-11,0.23613515726845796,615807.3186711414,6.661677342261465,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M4-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,401.3,2.22,,,48.0,11.04,48.72,10.59,40.61,0.0054096000000000005,-0.12974136,44.8,1.8042700818317172,11.040004286971568,2.069578654615484e-11,0.23917582430403733,615946.1037566229,7.186242472467869,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M4H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,400.4,2.22,,,48.0,11.04,48.72,10.59,40.61,0.00521088,-0.13271328,45.0,1.8189624204961012,11.04000423343902,2.5739809408992726e-11,0.23613515726845796,615807.3186711414,6.661677342261465,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M4H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,401.3,2.22,,,48.0,11.04,48.72,10.59,40.61,0.0054096000000000005,-0.12974136,44.8,1.8042700818317172,11.040004286971568,2.069578654615484e-11,0.23917582430403733,615946.1037566229,7.186242472467869,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,430.0,402.1,2.16,,,72.0,11.12,49.39,10.4,41.35,0.00509296,-0.13147618,44.2,1.8516913671608228,11.13404372729692,2.828038574422001e-11,0.2187123927108038,173.1792109647989,10.045767077733384,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,430.0,402.1,2.16,,,72.0,11.12,49.39,10.4,41.35,0.00509296,-0.13147618,44.2,1.8516913671608228,11.13404372729692,2.828038574422001e-11,0.2187123927108038,173.1792109647989,10.045767077733384,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,401.5,2.1,,,48.0,11.12,48.96,10.59,40.61,0.005459919999999999,-0.12993984000000003,45.09,1.8058424829959496,11.121851994197597,1.863655932469027e-11,0.2614168657901889,1569.6352922193516,6.587546008108707,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,408.9,1.94,,,18.0,13.6,39.7,13.0,33.1,0.005984,-0.089325,43.1,1.3615245589019083,13.601931297878645,2.9458270264850037e-12,0.1763198932523247,1241.6264693260675,6.516770186105644,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS430M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,430.0,408.9,1.94,,,18.0,13.6,39.7,13.0,33.1,0.005984,-0.089325,43.1,1.3615245589019083,13.601931297878645,2.9458270264850037e-12,0.1763198932523247,1241.6264693260675,6.516770186105644,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M4-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,405.2,2.22,,,48.0,11.13,48.85,10.66,40.81,0.00525336,-0.1330674,45.0,1.8244500225753428,11.130004159098045,2.6192318596735825e-11,0.22534887416679353,603058.5484186768,6.7420911616743044,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M4-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,406.1,2.22,,,48.0,11.13,48.85,10.66,40.81,0.0054537000000000006,-0.13008755,44.8,1.80972183174209,11.130004214044028,2.106387940166946e-11,0.22838538669399186,603213.5388588556,7.2689551006971485,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M4H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,405.2,2.22,,,48.0,11.13,48.85,10.66,40.81,0.00525336,-0.1330674,45.0,1.8244500225753428,11.130004159098045,2.6192318596735825e-11,0.22534887416679353,603058.5484186768,6.7420911616743044,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M4H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,406.1,2.22,,,48.0,11.13,48.85,10.66,40.81,0.0054537000000000006,-0.13008755,44.8,1.80972183174209,11.130004214044028,2.106387940166946e-11,0.22838538669399186,603213.5388588556,7.2689551006971485,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,435.0,406.9,2.16,,,72.0,11.18,49.45,10.5,41.43,0.0051204399999999995,-0.1316359,44.2,1.850771601548645,11.191216303271885,2.729608291324352e-11,0.21513150709424558,214.43520263545147,9.664880099543803,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,435.0,406.9,2.16,,,72.0,11.18,49.45,10.5,41.43,0.0051204399999999995,-0.1316359,44.2,1.850771601548645,11.191216303271885,2.729608291324352e-11,0.21513150709424558,214.43520263545147,9.664880099543803,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,406.3,2.1,,,48.0,11.2,49.17,10.66,40.81,0.005499199999999999,-0.13049718000000002,45.09,1.8146587985108402,11.202360564883774,1.9059172504775414e-11,0.257843102816861,1223.369398780426,6.722369977796833,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,413.7,1.94,,,18.0,13.69,39.9,13.08,33.3,0.0060236,-0.08977500000000001,43.1,1.3692804892140549,13.692451020546912,3.0206040420140266e-12,0.1731505720893587,967.1201477852975,6.682529256615203,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS435M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,435.0,413.7,1.94,,,18.0,13.69,39.9,13.08,33.3,0.0060236,-0.08977500000000001,43.1,1.3692804892140549,13.692451020546912,3.0206040420140266e-12,0.1731505720893587,967.1201477852975,6.682529256615203,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,418.4,1.98,,,16.0,15.73,35.2,14.96,29.4,0.0066066,-0.083424,43.1,1.2114337404170976,15.738038660301097,3.7503991456427536e-12,0.13105685235853018,256.4512262838931,1.947966330190542,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS440L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,418.4,1.98,,,16.0,15.73,35.2,14.96,29.4,0.0066066,-0.083424,43.1,1.2114337404170976,15.738038660301097,3.7503991456427536e-12,0.13105685235853018,256.4512262838931,1.947966330190542,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS440M4-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,409.9,2.22,,,48.0,11.21,48.98,10.73,41.01,0.00529112,-0.13342152,45.0,1.8306118604602506,11.210004053733666,2.6889582110197843e-11,0.21473113679259556,593817.8841035683,6.907363601099142,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M4-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,410.9,2.22,,,48.0,11.21,48.98,10.73,41.01,0.0054929,-0.13043374,44.8,1.8158283268913127,11.210004109846041,2.1626183555835196e-11,0.2177657218301505,593985.7952702694,7.435968485846143,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M4H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,409.9,2.22,,,48.0,11.21,48.98,10.73,41.01,0.00529112,-0.13342152,45.0,1.8306118604602506,11.210004053733666,2.6889582110197843e-11,0.21473113679259556,593817.8841035683,6.907363601099142,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M4H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,410.9,2.22,,,48.0,11.21,48.98,10.73,41.01,0.0054929,-0.13043374,44.8,1.8158283268913127,11.210004109846041,2.1626183555835196e-11,0.2177657218301505,593985.7952702694,7.435968485846143,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,440.0,411.7,2.16,,,72.0,11.24,49.51,10.6,41.51,0.00514792,-0.13179562,44.2,1.8290236959409958,11.240007504396607,1.9715415422795467e-11,0.2156497446958225,323000.08288986905,6.692356590475035,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,440.0,411.7,2.16,,,72.0,11.24,49.51,10.6,41.51,0.00514792,-0.13179562,44.2,1.8290236959409958,11.240007504396607,1.9715415422795467e-11,0.2156497446958225,323000.08288986905,6.692356590475035,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,411.1,2.1,,,48.0,11.28,49.38,10.73,41.01,0.005538479999999999,-0.13105452,45.09,1.8234749512399198,11.28285719971649,1.9487504658385664e-11,0.2543161900043095,1004.020174092487,6.856035633867367,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,418.6,1.94,,,18.0,13.78,40.0,13.16,33.4,0.0060631999999999995,-0.09000000000000001,43.1,1.3732933374573257,13.78293916025109,3.0764140081140474e-12,0.17101473160194408,801.7881953158837,6.788866189125181,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS440M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,440.0,418.6,1.94,,,18.0,13.78,40.0,13.16,33.4,0.0060631999999999995,-0.09000000000000001,43.1,1.3732933374573257,13.78293916025109,3.0764140081140474e-12,0.17101473160194408,801.7881953158837,6.788866189125181,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,423.3,1.98,,,16.0,15.78,35.4,15.01,29.7,0.0066276,-0.08389799999999999,43.1,1.2207809156672822,15.78760349430685,3.988715905451991e-12,0.12132967816937835,251.8029538836263,2.442515896933573,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,423.3,1.98,,,16.0,15.78,35.4,15.01,29.7,0.0066276,-0.08389799999999999,43.1,1.2207809156672822,15.78760349430685,3.988715905451991e-12,0.12132967816937835,251.8029538836263,2.442515896933573,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445M4-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,414.7,2.22,,,48.0,11.29,49.11,10.8,41.21,0.00532888,-0.13377563999999997,45.0,1.8368438495314066,11.29000223421443,2.7628741204167953e-11,0.19788735369209592,999999.8753394441,7.08062717023163,-0.3528,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS445M4H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,414.7,2.22,,,48.0,11.29,49.11,10.8,41.21,0.00532888,-0.13377563999999997,45.0,1.8368438495314066,11.29000223421443,2.7628741204167953e-11,0.19788735369209592,999999.8753394441,7.08062717023163,-0.3528,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS445M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,445.0,416.5,2.16,,,72.0,11.3,49.57,10.7,41.59,0.0051754,-0.13195534,44.2,1.8491746926105381,11.30577806388407,2.5506895108808015e-11,0.20807861540860506,406.93360706131233,8.934816141060324,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,445.0,416.5,2.16,,,72.0,11.3,49.57,10.7,41.59,0.0051754,-0.13195534,44.2,1.8491746926105381,11.30577806388407,2.5506895108808015e-11,0.20807861540860506,406.93360706131233,8.934816141060324,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,415.9,2.1,,,48.0,11.36,49.59,10.8,41.21,0.005577759999999999,-0.13161186000000002,45.09,1.8322901703409225,11.363342065625776,1.9921340983794055e-11,0.25083537103395986,852.6133826984893,6.988458567133795,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,423.5,1.94,,,18.0,13.87,40.2,13.24,33.6,0.006102799999999999,-0.09045,43.1,1.3810491961114209,13.873426174254792,3.153208261100298e-12,0.16791608445486128,679.7658062326268,6.952032397502582,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS445M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,445.0,423.5,1.94,,,18.0,13.87,40.2,13.24,33.6,0.006102799999999999,-0.09045,43.1,1.3810491961114209,13.873426174254792,3.153208261100298e-12,0.16791608445486128,679.7658062326268,6.952032397502582,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,428.1,1.98,,,16.0,15.83,35.6,15.06,29.9,0.0066486,-0.084372,43.1,1.2282065141903549,15.837385963953551,4.051973177083621e-12,0.11920824698407137,255.4936046725797,2.548621754296907,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,428.1,1.98,,,16.0,15.83,35.6,15.06,29.9,0.0066486,-0.084372,43.1,1.2282065141903549,15.837385963953551,4.051973177083621e-12,0.11920824698407137,255.4936046725797,2.548621754296907,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M4-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,419.5,2.22,,,48.0,11.38,49.24,10.87,41.4,0.00537136,-0.13412976,45.0,1.842114644127289,11.380013637369771,2.8013976701721324e-11,0.1949394183222071,162672.1336630844,7.131916430747761,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M4H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,419.5,2.22,,,48.0,11.38,49.24,10.87,41.4,0.00537136,-0.13412976,45.0,1.842114644127289,11.380013637369771,2.8013976701721324e-11,0.1949394183222071,162672.1336630844,7.131916430747761,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,450.0,421.3,2.16,,,72.0,11.36,49.63,10.8,41.67,0.00520288,-0.13211506,44.2,1.840575810589645,11.360006997557715,2.2125244713972664e-11,0.20610667777341343,334601.15204539505,7.601737442723406,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,450.0,421.3,2.16,,,72.0,11.36,49.63,10.8,41.67,0.00520288,-0.13211506,44.2,1.840575810589645,11.360006997557715,2.2125244713972664e-11,0.20610667777341343,334601.15204539505,7.601737442723406,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,420.7,2.1,,,48.0,11.44,49.79,10.87,41.4,0.00561704,-0.13214266000000002,45.09,1.8406973621215181,11.443815507720293,2.03495773863603e-11,0.2475280605482743,742.1610713188148,7.114897189674918,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,428.3,1.94,,,18.0,13.96,40.3,13.32,33.8,0.0061424,-0.09067499999999999,43.1,1.3869409370079402,13.963894892307586,3.3388018413672795e-12,0.15732294943826494,563.8739688837506,7.405528400975875,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS450M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,450.0,428.3,1.94,,,18.0,13.96,40.3,13.32,33.8,0.0061424,-0.09067499999999999,43.1,1.3869409370079402,13.963894892307586,3.3388018413672795e-12,0.15732294943826494,563.8739688837506,7.405528400975875,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,433.0,1.98,,,16.0,15.88,35.8,15.11,30.1,0.006669600000000001,-0.08484599999999999,43.1,1.235631069237917,15.887172333909875,4.1154758130715525e-12,0.11710142972867794,259.26995760112425,2.653341241478948,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,433.0,1.98,,,16.0,15.88,35.8,15.11,30.1,0.006669600000000001,-0.08484599999999999,43.1,1.235631069237917,15.887172333909875,4.1154758130715525e-12,0.11710142972867794,259.26995760112425,2.653341241478948,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M4-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,424.3,2.22,,,48.0,11.47,49.37,10.94,41.6,0.0054138400000000005,-0.13448387999999997,45.0,1.847612531710242,11.470006947550411,2.8496236156626197e-11,0.18471211018695616,304951.5924271711,7.211596613726295,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M4H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,424.3,2.22,,,48.0,11.47,49.37,10.94,41.6,0.0054138400000000005,-0.13448387999999997,45.0,1.847612531710242,11.470006947550411,2.8496236156626197e-11,0.18471211018695616,304951.5924271711,7.211596613726295,-0.3528,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,455.0,426.1,2.16,,,72.0,11.42,49.69,10.9,41.75,0.00523036,-0.13227478,44.2,1.8478768586131773,11.420624439743797,2.3925354033843793e-11,0.20117286667120945,3679.128974775023,8.243890334556474,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,455.0,426.1,2.16,,,72.0,11.42,49.69,10.9,41.75,0.00523036,-0.13227478,44.2,1.8478768586131773,11.420624439743797,2.3925354033843793e-11,0.20117286667120945,3679.128974775023,8.243890334556474,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M5H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,425.5,2.1,,,48.0,11.52,50.01,10.94,41.6,0.005656319999999999,-0.13272654,45.09,1.8118924382739177,11.520084912402089,1.1869953309346518e-11,0.25255702251457585,34264.23522577877,2.4443530293092954,-0.3445,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M8GFH-18/VNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,433.2,1.94,,,18.0,14.05,40.5,13.4,34.0,0.006182,-0.09112500000000001,43.1,1.3946973640728677,14.05431791613357,3.419993219657217e-12,0.15434385711645118,502.217072547287,7.564560960557895,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS455M8GFH-18/VNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,455.0,433.2,1.94,,,18.0,14.05,40.5,13.4,34.0,0.006182,-0.09112500000000001,43.1,1.3946973640728677,14.05431791613357,3.419993219657217e-12,0.15434385711645118,502.217072547287,7.564560960557895,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS460L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,460.0,437.9,1.98,,,16.0,15.93,36.0,15.16,30.4,0.0066906000000000005,-0.08532,43.1,1.2449662906776502,15.936715427968213,4.368001179789641e-12,0.10752657695268707,255.0691305473343,3.133444560190197,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS460L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,460.0,437.9,1.98,,,16.0,15.93,36.0,15.16,30.4,0.0066906000000000005,-0.08532,43.1,1.2449662906776502,15.936715427968213,4.368001179789641e-12,0.10752657695268707,255.0691305473343,3.133444560190197,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS460M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,460.0,430.9,2.16,,,72.0,11.48,49.75,11.0,41.82,0.005257840000000001,-0.13243449999999998,44.2,1.8405445833545524,11.480003992474815,2.0938234918651362e-11,0.20021518078267506,575708.1385291264,7.030669210873781,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS460M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,460.0,430.9,2.16,,,72.0,11.48,49.75,11.0,41.82,0.005257840000000001,-0.13243449999999998,44.2,1.8405445833545524,11.480003992474815,2.0938234918651362e-11,0.20021518078267506,575708.1385291264,7.030669210873781,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS465L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,465.0,442.7,1.98,,,16.0,15.98,36.2,15.21,30.6,0.006711600000000001,-0.08579400000000001,43.1,1.2523873473237213,15.986510531541139,4.433484169163649e-12,0.10547431663958191,258.88509601859283,3.2331090078161844,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS465L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,465.0,442.7,1.98,,,16.0,15.98,36.2,15.21,30.6,0.006711600000000001,-0.08579400000000001,43.1,1.2523873473237213,15.986510531541139,4.433484169163649e-12,0.10547431663958191,258.88509601859283,3.2331090078161844,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS465M5GF-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,465.0,435.7,2.16,,,72.0,11.54,49.81,11.1,41.9,0.00528532,-0.13259422,44.2,1.844989971565306,11.540003905568781,2.1745276121621e-11,0.19595255090469657,578999.5926916343,7.313943939875598,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS465M5GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,1,465.0,435.7,2.16,,,72.0,11.54,49.81,11.1,41.9,0.00528532,-0.13259422,44.2,1.844989971565306,11.540003905568781,2.1745276121621e-11,0.19595255090469657,578999.5926916343,7.313943939875598,-0.3498,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS470L8GFH-16/QNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,470.0,447.6,1.98,,,16.0,16.03,36.4,15.23,30.9,0.006732600000000002,-0.086268,43.1,1.2628406026122145,16.037627198629586,4.810131276226175e-12,0.09587763961970401,201.50498757795182,3.913134803632209,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS470L8GFH-16/QNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,470.0,447.6,1.98,,,16.0,16.03,36.4,15.23,30.9,0.006732600000000002,-0.086268,43.1,1.2628406026122145,16.037627198629586,4.810131276226175e-12,0.09587763961970401,201.50498757795182,3.913134803632209,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS520M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,520.0,486.2,2.5,,,48.0,13.22,48.99,12.7,40.95,0.006226620000000001,-0.12742299,44.77,1.7691490833912114,13.220004946208748,1.244684070686999e-11,0.19866999526062518,531000.616778066,3.807499176136273,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS525M6H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,525.0,490.5,2.5,,,48.0,13.32,49.09,12.79,41.05,0.007192800000000001,-0.13401570000000002,44.49,1.8123344905027028,13.320004774378466,2.295807674293236e-11,0.1893526445188187,528281.0924937322,3.7613782606625352,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS525M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,525.0,491.0,2.5,,,48.0,13.32,49.09,12.79,41.05,0.006273720000000001,-0.12768309000000003,44.77,1.771019054523702,13.320004955323906,1.2204155007941042e-11,0.19650140283851456,528203.7155045083,3.577349421539889,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS530M6H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,530.0,495.3,2.5,,,48.0,13.42,49.19,12.88,41.15,0.0072468,-0.1342887,44.49,1.8595118426953288,13.420061833028686,4.357565332878442e-11,0.17953871765405713,38966.457750703106,9.22890662136763,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS530M8GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,530.0,493.0,2.5,,,48.0,13.61,49.16,12.97,40.87,0.0050357,-0.13273200000000002,44.47,1.867674971129391,13.61053349116037,5.038283649788712e-11,0.19721127176813597,5031.097703237676,11.847765057243233,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS530M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,530.0,495.8,2.5,,,48.0,13.42,49.19,12.88,41.15,0.006320820000000001,-0.12794319,44.77,1.8188560910067015,13.420089499415333,2.4123157098446742e-11,0.18646483019211474,27959.512351153462,9.4117461734246,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS535M6H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,535.0,500.1,2.5,,,48.0,13.52,49.29,12.97,41.25,0.007300799999999999,-0.1345617,44.49,1.8634778704784587,13.520002161004738,4.402006393532463e-11,0.15983020127654135,999998.1293529588,9.252663028890732,-0.356,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS535M6H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,535.0,500.1,2.5,,,48.0,13.52,49.29,12.97,41.25,0.007300799999999999,-0.1345617,44.49,1.8634778704784587,13.520002161004738,4.402006393532463e-11,0.15983020127654135,999998.1293529588,9.252663028890732,-0.356,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS535M8GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,535.0,497.8,2.5,,,48.0,13.69,49.31,13.04,41.03,0.005065299999999999,-0.133137,44.47,1.8746304152943285,13.691029750315417,5.154779581436884e-11,0.1934982168116449,2572.4576752880635,12.003688577979274,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS535M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,535.0,500.6,2.5,,,48.0,13.52,49.29,12.97,41.25,0.00636792,-0.12820329,44.77,1.8226968860054704,13.520181081749216,2.435149378539353e-11,0.18407335260692204,13743.443162084855,9.42996635631591,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS540M6H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,540.0,504.9,2.5,,,48.0,13.62,49.39,13.06,41.35,0.007354799999999999,-0.1348347,44.49,1.8672071904530894,13.620002170271054,4.43134292659193e-11,0.15933711102777634,999998.9876859289,9.246234900872945,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS540M6H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,540.0,504.9,2.5,,,48.0,13.62,49.39,13.06,41.35,0.007354799999999999,-0.1348347,44.49,1.8672071904530894,13.620002170271054,4.43134292659193e-11,0.15933711102777634,999998.9876859289,9.246234900872945,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS540M8GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,540.0,502.6,2.5,,,48.0,13.78,49.45,13.11,41.19,0.0050986,-0.13351500000000002,44.47,1.8820628988016013,13.782169636144532,5.3358858504827905e-11,0.18885155942675494,1199.4520304783084,12.262552741246381,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS540M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,540.0,505.5,2.5,,,48.0,13.62,49.39,13.06,41.35,0.00641502,-0.12846339,44.77,1.8261492870426455,13.620065560490996,2.4446513495171256e-11,0.18177554950474206,37763.3786565863,9.398503564842306,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS545M6H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,545.0,509.7,2.5,,,48.0,13.72,49.49,13.15,41.45,0.007408800000000001,-0.13510770000000002,44.49,1.8707846529969228,13.72005634277569,4.450731520446248e-11,0.17262907651911694,42036.90121948361,9.220449045417146,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS545M8GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,545.0,507.3,2.5,,,48.0,13.86,49.6,13.18,41.35,0.005128199999999999,-0.13392,44.47,1.8890179331921544,13.862617887610615,5.4572601698187225e-11,0.1852228388137772,980.6336567664495,12.41627809059884,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS545M8H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,545.0,513.6,2.58,,,72.0,13.92,49.65,13.04,41.8,0.0055958399999999995,-0.1418997,43.1,1.8330873743521034,13.935626142449404,2.344926331398915e-11,0.1608527169063229,143.2899921593584,-0.8342547567182711,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS545M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,545.0,510.3,2.5,,,48.0,13.72,49.49,13.15,41.45,0.006462120000000001,-0.12872349,44.77,1.7797521197856325,13.720004966729645,1.1503208182398787e-11,0.18792384981680352,519121.2036822325,2.830370363166766,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS550M6H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,550.0,514.5,2.5,,,48.0,13.82,49.59,13.24,41.55,0.007462800000000001,-0.13538070000000002,44.49,1.68306763854484,13.82046873384911,2.2089445547160667e-12,0.20271688189190032,5976.839987401369,-14.651952970042759,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS550M8GFH-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,550.0,512.1,2.5,,,48.0,13.95,49.74,13.25,41.51,0.005161499999999999,-0.134298,44.47,1.8964516681949573,13.953676781849877,5.646500957639237e-11,0.18066891164385035,685.4721133399942,12.672647384446142,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS550M8H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,550.0,518.4,2.58,,,72.0,13.99,49.8,13.11,41.95,0.00562398,-0.1423284,43.1,1.8388505292419084,14.005276595451738,2.3653632585623918e-11,0.15849784888134613,145.14915463236258,-0.8059974901319501,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS550M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,550.0,515.1,2.5,,,48.0,13.82,49.59,13.24,41.55,0.006509220000000001,-0.12898359,44.77,1.8334993686189605,13.820002323751055,2.4791307209569902e-11,0.16813706796506606,999993.1677560833,9.393085282371288,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS555M8H-24/TH,Phono Solar Technology Co Ltd,Mono-c-Si,0,555.0,523.3,2.58,,,72.0,14.02,49.95,13.18,42.09,0.005636039999999999,-0.14275710000000003,43.1,1.8417537947107199,14.032870391893294,2.2888117476446714e-11,0.1578597079971288,171.96004051326483,-1.1000082370574973,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS555M8H-24/THB,Phono Solar Technology Co Ltd,Mono-c-Si,0,555.0,519.9,2.5,,,48.0,13.92,49.69,13.33,41.64,0.00655632,-0.12924369,44.77,1.7381451424631436,13.92000266882168,5.346265306490593e-12,0.19172370903837344,999996.9380482815,100.00000040594377,-0.3452,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS565M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,565.0,537.2,2.56,,,24.0,13.48,52.1,12.93,43.7,0.0059312,-0.11722500000000001,43.1,1.7906204260756649,13.48000278524619,3.1147976880417236e-12,0.2066195609880179,999998.9852681692,7.079142420745837,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS565M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,565.0,537.2,2.56,,,24.0,13.48,52.1,12.93,43.7,0.0059312,-0.11722500000000001,43.1,1.7906204260756649,13.48000278524619,3.1147976880417236e-12,0.2066195609880179,999998.9852681692,7.079142420745837,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS570M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,570.0,542.1,2.56,,,24.0,13.54,52.3,12.98,43.9,0.0059575999999999995,-0.117675,43.1,1.797601510471563,13.540002789030272,3.1341003221417646e-12,0.20598352511829685,999999.4188072613,7.094538116028009,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS570M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,570.0,542.1,2.56,,,24.0,13.54,52.3,12.98,43.9,0.0059575999999999995,-0.117675,43.1,1.797601510471563,13.540002789030272,3.1341003221417646e-12,0.20598352511829685,999999.4188072613,7.094538116028009,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS575M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,575.0,546.9,2.56,,,24.0,13.6,52.5,13.03,44.1,0.005984,-0.11812500000000001,43.1,1.8048454284357656,13.60015867486159,3.1661582806879885e-12,0.20468994934538157,17543.94758868488,7.146440160841605,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS575M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,575.0,546.9,2.56,,,24.0,13.6,52.5,13.03,44.1,0.005984,-0.11812500000000001,43.1,1.8048454284357656,13.60015867486159,3.1661582806879885e-12,0.20468994934538157,17543.94758868488,7.146440160841605,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS580M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,580.0,551.8,2.56,,,24.0,13.66,52.7,13.08,44.4,0.0060104,-0.11857500000000001,43.1,1.8146315436506428,13.660818185525365,3.3289176959906323e-12,0.19310286544225327,3223.9458080055792,7.556582738200181,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS580M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,580.0,551.8,2.56,,,24.0,13.66,52.7,13.08,44.4,0.0060104,-0.11857500000000001,43.1,1.8146315436506428,13.660818185525365,3.3289176959906323e-12,0.19310286544225327,3223.9458080055792,7.556582738200181,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS585M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,585.0,556.6,2.56,,,24.0,13.72,52.9,13.13,44.6,0.0060368,-0.119025,43.1,1.8225563341933564,13.721322450739232,3.3968578383017182e-12,0.19023153201498985,1973.5908792166063,7.700505606457398,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS585M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,585.0,556.6,2.56,,,24.0,13.72,52.9,13.13,44.6,0.0060368,-0.119025,43.1,1.8225563341933564,13.721322450739232,3.3968578383017182e-12,0.19023153201498985,1973.5908792166063,7.700505606457398,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS590M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,590.0,561.5,2.56,,,24.0,13.78,53.0,13.18,44.8,0.0060631999999999995,-0.11925000000000001,43.1,1.8286085238780447,13.78184875520147,3.5527165555647787e-12,0.17977918948704344,1340.013534005762,8.065521238843349,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS590M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,590.0,561.5,2.56,,,24.0,13.78,53.0,13.18,44.8,0.0060631999999999995,-0.11925000000000001,43.1,1.8286085238780447,13.78184875520147,3.5527165555647787e-12,0.17977918948704344,1340.013534005762,8.065521238843349,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS595M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,595.0,566.4,2.56,,,24.0,13.84,53.2,13.23,45.0,0.0060896,-0.11970000000000001,43.1,1.8365363633173541,13.842299584866717,3.62394457005008e-12,0.17697947702499753,1065.147085024721,8.207146521252707,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS595M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,595.0,566.4,2.56,,,24.0,13.84,53.2,13.23,45.0,0.0060896,-0.11970000000000001,43.1,1.8365363633173541,13.842299584866717,3.62394457005008e-12,0.17697947702499753,1065.147085024721,8.207146521252707,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS600M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,600.0,571.2,2.56,,,24.0,13.9,53.4,13.28,45.2,0.006116,-0.12015,43.1,1.8444655281713358,13.902735297269915,3.696114288478612e-12,0.17420048855824413,885.23700769823,8.347892788074406,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS600M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,600.0,571.2,2.56,,,24.0,13.9,53.4,13.28,45.2,0.006116,-0.12015,43.1,1.8444655281713358,13.902735297269915,3.696114288478612e-12,0.17420048855824413,885.23700769823,8.347892788074406,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS605L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,605.0,575.5,2.68,,,22.0,15.71,48.3,14.94,40.5,0.006598200000000001,-0.11447099999999999,43.1,1.665372547946536,15.71784709474558,3.9515991332873535e-12,0.1680084986820972,336.3555054173159,2.4018693528497352,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS605L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,605.0,575.5,2.68,,,22.0,15.71,48.3,14.94,40.5,0.006598200000000001,-0.11447099999999999,43.1,1.665372547946536,15.71784709474558,3.9515991332873535e-12,0.1680084986820972,336.3555054173159,2.4018693528497352,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS605M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,605.0,576.1,2.56,,,24.0,13.96,53.6,13.33,45.4,0.0061424,-0.12060000000000001,43.1,1.8523961148259946,13.963156129592962,3.769236585332359e-12,0.1714419762620931,758.3117014300051,8.487783013582488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS605M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,605.0,576.1,2.56,,,24.0,13.96,53.6,13.33,45.4,0.0061424,-0.12060000000000001,43.1,1.8523961148259946,13.963156129592962,3.769236585332359e-12,0.1714419762620931,758.3117014300051,8.487783013582488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS610L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,610.0,580.4,2.68,,,22.0,15.75,48.5,14.98,40.7,0.006615,-0.11494499999999999,43.1,1.6727906028044455,15.757674190147704,3.998009612995591e-12,0.16583407952854057,340.3468727135544,2.478869399872595,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS610L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,610.0,580.4,2.68,,,22.0,15.75,48.5,14.98,40.7,0.006615,-0.11494499999999999,43.1,1.6727906028044455,15.757674190147704,3.998009612995591e-12,0.16583407952854057,340.3468727135544,2.478869399872595,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS610M8GFH-24/TNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,610.0,581.0,2.56,,,24.0,14.02,53.8,13.38,45.6,0.0061687999999999995,-0.12105,43.1,1.8603280483494393,14.023562226221152,3.843312898009671e-12,0.1687037230431541,663.9741860106104,8.62681653995585,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS610M8GFH-24/TNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,610.0,581.0,2.56,,,24.0,14.02,53.8,13.38,45.6,0.0061687999999999995,-0.12105,43.1,1.8603280483494393,14.023562226221152,3.843312898009671e-12,0.1687037230431541,663.9741860106104,8.62681653995585,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS610M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,610.0,580.0,2.77,,,26.0,13.61,56.0,12.97,47.0,0.0059884,-0.12600000000000003,43.1,1.9289122039117383,13.614899543116952,3.331979539583315e-12,0.22134374590346995,614.8509026735204,7.619517300767959,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS610M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,610.0,580.0,2.77,,,26.0,13.61,56.0,12.97,47.0,0.0059884,-0.12600000000000003,43.1,1.9289122039117383,13.614899543116952,3.331979539583315e-12,0.22134374590346995,614.8509026735204,7.619517300767959,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS615L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,615.0,585.2,2.68,,,22.0,15.79,48.8,15.02,41.0,0.0066318,-0.115656,43.1,1.683964667678295,15.797475360035463,4.065826524776967e-12,0.16279752849697673,343.8727991438359,2.5997088924280756,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS615L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,615.0,585.2,2.68,,,22.0,15.79,48.8,15.02,41.0,0.0066318,-0.115656,43.1,1.683964667678295,15.797475360035463,4.065826524776967e-12,0.16279752849697673,343.8727991438359,2.5997088924280756,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS615M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,615.0,584.8,2.77,,,26.0,13.65,56.2,13.01,47.3,0.006006,-0.12645,43.1,1.9381642214222508,13.654703907111815,3.461896534972871e-12,0.20997547342060655,609.3158852207074,7.934651930428964,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS615M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,615.0,584.8,2.77,,,26.0,13.65,56.2,13.01,47.3,0.006006,-0.12645,43.1,1.9381642214222508,13.654703907111815,3.461896534972871e-12,0.20997547342060655,609.3158852207074,7.934651930428964,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS620L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,620.0,590.1,2.68,,,22.0,15.83,49.0,15.06,41.2,0.0066486,-0.11613,43.1,1.6913806628780814,15.837307518314354,4.112553529155163e-12,0.16064957955154444,348.0090968705184,2.6748260338784022,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS620L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,620.0,590.1,2.68,,,22.0,15.83,49.0,15.06,41.2,0.0066486,-0.11613,43.1,1.6913806628780814,15.837307518314354,4.112553529155163e-12,0.16064957955154444,348.0090968705184,2.6748260338784022,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS620M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,620.0,589.7,2.77,,,26.0,13.69,56.5,13.05,47.5,0.0060236,-0.12712500000000002,43.1,1.9474004273564471,13.694627367677361,3.4160408781362563e-12,0.2150502559771934,636.223057452169,7.788493060965829,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS620M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,620.0,589.7,2.77,,,26.0,13.69,56.5,13.05,47.5,0.0060236,-0.12712500000000002,43.1,1.9474004273564471,13.694627367677361,3.4160408781362563e-12,0.2150502559771934,636.223057452169,7.788493060965829,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS625L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,625.0,595.0,2.68,,,22.0,15.87,49.2,15.1,41.4,0.006665400000000001,-0.116604,43.1,1.6987958951781175,15.877142104862942,4.1594167966110695e-12,0.15851342677774893,352.2222279040189,2.749225516466034,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS625L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,625.0,595.0,2.68,,,22.0,15.87,49.2,15.1,41.4,0.006665400000000001,-0.116604,43.1,1.6987958951781175,15.877142104862942,4.1594167966110695e-12,0.15851342677774893,352.2222279040189,2.749225516466034,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS625M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,625.0,594.5,2.77,,,26.0,13.73,56.7,13.09,47.8,0.0060412,-0.12757500000000002,43.1,1.9566483177646796,13.7344375974963,3.5474634925366655e-12,0.20377405279117067,630.4802892017698,8.099721782690692,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS625M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,625.0,594.5,2.77,,,26.0,13.73,56.7,13.09,47.8,0.0060412,-0.12757500000000002,43.1,1.9566483177646796,13.7344375974963,3.5474634925366655e-12,0.20377405279117067,630.4802892017698,8.099721782690692,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS630L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,630.0,599.8,2.68,,,22.0,15.91,49.4,15.14,41.6,0.0066822,-0.11707799999999999,43.1,1.7062103750994262,15.916979103172057,4.2064146247823375e-12,0.15638897107933605,356.5140780790337,2.822917471469596,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS630L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,630.0,599.8,2.68,,,22.0,15.91,49.4,15.14,41.6,0.0066822,-0.11707799999999999,43.1,1.7062103750994262,15.916979103172057,4.2064146247823375e-12,0.15638897107933605,356.5140780790337,2.822917471469596,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS630M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,630.0,599.4,2.77,,,26.0,13.77,56.9,13.13,48.0,0.006058799999999999,-0.128025,43.1,1.9640163365285295,13.774313254979292,3.582744005656822e-12,0.2012007917654354,642.3304516789796,8.161717297960164,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS630M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,630.0,599.4,2.77,,,26.0,13.77,56.9,13.13,48.0,0.006058799999999999,-0.128025,43.1,1.9640163365285295,13.774313254979292,3.582744005656822e-12,0.2012007917654354,642.3304516789796,8.161717297960164,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS635L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,635.0,604.7,2.68,,,22.0,15.95,49.6,15.18,41.8,0.006699000000000001,-0.117552,43.1,1.7136241082886654,15.956818493304853,4.253545014748164e-12,0.15427611513801762,360.88677191455844,2.895911235303039,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS635L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,635.0,604.7,2.68,,,22.0,15.95,49.6,15.18,41.8,0.006699000000000001,-0.117552,43.1,1.7136241082886654,15.956818493304853,4.253545014748164e-12,0.15427611513801762,360.88677191455844,2.895911235303039,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS635M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,635.0,604.3,2.77,,,26.0,13.81,57.1,13.17,48.2,0.0060764,-0.128475,43.1,1.9713837437927155,13.814191036812618,3.6181248715152003e-12,0.19864354714129037,654.5557859734351,8.223200231477934,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS635M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,635.0,604.3,2.77,,,26.0,13.81,57.1,13.17,48.2,0.0060764,-0.128475,43.1,1.9713837437927155,13.814191036812618,3.6181248715152003e-12,0.19864354714129037,654.5557859734351,8.223200231477934,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS640L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,640.0,609.6,2.68,,,22.0,15.99,49.9,15.22,42.1,0.006715800000000001,-0.118263,43.1,1.724792245056884,15.996633048789517,4.322310675777407e-12,0.1513131186413911,364.76390361614665,3.010762570157835,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS640L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,640.0,609.6,2.68,,,22.0,15.99,49.9,15.22,42.1,0.006715800000000001,-0.118263,43.1,1.724792245056884,15.996633048789517,4.322310675777407e-12,0.1513131186413911,364.76390361614665,3.010762570157835,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS640M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,640.0,609.1,2.77,,,26.0,13.85,57.3,13.21,48.5,0.0060940000000000005,-0.12892499999999998,43.1,1.980623620977026,13.85400216402484,3.754366508030777e-12,0.18752669757940515,648.9601010315081,8.528633118117629,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS640M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,640.0,609.1,2.77,,,26.0,13.85,57.3,13.21,48.5,0.0060940000000000005,-0.12892499999999998,43.1,1.980623620977026,13.85400216402484,3.754366508030777e-12,0.18752669757940515,648.9601010315081,8.528633118117629,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS645L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,645.0,614.5,2.68,,,22.0,16.03,50.1,15.26,42.3,0.006732600000000002,-0.118737,43.1,1.732204138533144,16.036477438590495,4.369739111717279e-12,0.14922562392070376,369.2951642484751,3.0820249349207627,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS645L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,645.0,614.5,2.68,,,22.0,16.03,50.1,15.26,42.3,0.006732600000000002,-0.118737,43.1,1.732204138533144,16.036477438590495,4.369739111717279e-12,0.14922562392070376,369.2951642484751,3.0820249349207627,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS645M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,645.0,614.0,2.77,,,26.0,13.89,57.6,13.25,48.7,0.006111599999999999,-0.12960000000000002,43.1,1.9898608754775595,13.893943341879169,3.704679873974037e-12,0.19258980480740165,678.3769902823667,8.382304212630302,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS645M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,645.0,614.0,2.77,,,26.0,13.89,57.6,13.25,48.7,0.006111599999999999,-0.12960000000000002,43.1,1.9898608754775595,13.893943341879169,3.704679873974037e-12,0.19258980480740165,678.3769902823667,8.382304212630302,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS650L8GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,650.0,619.3,2.68,,,22.0,16.07,50.3,15.3,42.5,0.006749400000000001,-0.119211,43.1,1.7396153223997144,16.076324174200263,4.417294522078489e-12,0.14714942621761973,373.9130523830637,3.1526232223684194,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS650L8GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,650.0,619.3,2.68,,,22.0,16.07,50.3,15.3,42.5,0.006749400000000001,-0.119211,43.1,1.7396153223997144,16.076324174200263,4.417294522078489e-12,0.14714942621761973,373.9130523830637,3.1526232223684194,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS650M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,650.0,618.9,2.77,,,26.0,13.93,57.8,13.29,48.9,0.0061292,-0.13005,43.1,1.9972262750636725,13.933827740080345,3.740390434610998e-12,0.19008286835916038,691.7539897412036,8.442025390326942,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS650M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,650.0,618.9,2.77,,,26.0,13.93,57.8,13.29,48.9,0.0061292,-0.13005,43.1,1.9972262750636725,13.933827740080345,3.740390434610998e-12,0.19008286835916038,691.7539897412036,8.442025390326942,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS655M8GFH-26/RNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,655.0,623.7,2.77,,,26.0,13.97,58.0,13.33,49.1,0.006146800000000001,-0.1305,43.1,2.0045910913767324,13.973714178655404,3.776197321561961e-12,0.18759133844248946,705.5801882681326,8.501260948619159,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS655M8GFH-26/RNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,655.0,623.7,2.77,,,26.0,13.97,58.0,13.33,49.1,0.006146800000000001,-0.1305,43.1,2.0045910913767324,13.973714178655404,3.776197321561961e-12,0.18759133844248946,705.5801882681326,8.501260948619159,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Phono Solar Technology Co Ltd PS700M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,700.0,666.2,3.08,,,22.0,18.1,48.6,17.44,40.1,0.007602000000000001,-0.11421,43.1,1.6583389195391955,18.100281718098707,3.3881825583411003e-12,0.18910792938696847,12149.92486547816,0.7494332954931694,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS700M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,700.0,666.2,3.08,,,22.0,18.1,48.6,17.44,40.1,0.007602000000000001,-0.11421,43.1,1.6583389195391955,18.100281718098707,3.3881825583411003e-12,0.18910792938696847,12149.92486547816,0.7494332954931694,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS705M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,705.0,671.1,3.08,,,22.0,18.14,48.8,17.48,40.3,0.007618800000000001,-0.11467999999999999,43.1,1.665790796007966,18.140283766092125,3.433348353808374e-12,0.18718984361529073,11966.278048175382,0.8417296499744439,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS705M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,705.0,671.1,3.08,,,22.0,18.14,48.8,17.48,40.3,0.007618800000000001,-0.11467999999999999,43.1,1.665790796007966,18.140283766092125,3.433348353808374e-12,0.18718984361529073,11966.278048175382,0.8417296499744439,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS710M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,710.0,675.9,3.08,,,22.0,18.18,49.0,17.52,40.5,0.0076356,-0.11514999999999999,43.1,1.6732429177224937,18.180285785009517,3.4787720349102765e-12,0.1852807865446611,11786.499529400582,0.9333085925375249,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS710M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,710.0,675.9,3.08,,,22.0,18.18,49.0,17.52,40.5,0.0076356,-0.11514999999999999,43.1,1.6732429177224937,18.180285785009517,3.4787720349102765e-12,0.1852807865446611,11786.499529400582,0.9333085925375249,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Phono Solar Technology Co Ltd PS715M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,715.0,680.8,3.08,,,22.0,18.22,49.2,17.56,40.7,0.0076524,-0.11562,43.1,1.6808201880364444,18.220003557703986,3.5328830541991726e-12,0.16645005709509922,852441.6978422353,1.0433465208637744,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS715M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,715.0,680.8,3.08,,,22.0,18.22,49.2,17.56,40.7,0.0076524,-0.11562,43.1,1.6808201880364444,18.220003557703986,3.5328830541991726e-12,0.16645005709509922,852441.6978422353,1.0433465208637744,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS720M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,720.0,685.7,3.08,,,22.0,18.26,49.4,17.6,40.9,0.007669200000000001,-0.11609,43.1,1.6882707184781267,18.26000347495252,3.578776517898373e-12,0.1644568187721056,864183.487375023,1.133157908322184,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS720M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,720.0,685.7,3.08,,,22.0,18.26,49.4,17.6,40.9,0.007669200000000001,-0.11609,43.1,1.6882707184781267,18.26000347495252,3.578776517898373e-12,0.1644568187721056,864183.487375023,1.133157908322184,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS725M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,725.0,690.6,3.08,,,22.0,18.3,49.6,17.64,41.1,0.007686000000000002,-0.11656000000000001,43.1,1.695721520685675,18.300003481374315,3.624924189874627e-12,0.16247101012944504,854040.3574110665,1.2222843166213078,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS725M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,725.0,690.6,3.08,,,22.0,18.3,49.6,17.64,41.1,0.007686000000000002,-0.11656000000000001,43.1,1.695721520685675,18.300003481374315,3.624924189874627e-12,0.16247101012944504,854040.3574110665,1.2222843166213078,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS730M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,730.0,695.4,3.08,,,22.0,18.34,49.7,17.68,41.3,0.007702800000000001,-0.11679500000000001,43.1,1.701101679942326,18.340003328401924,3.7574556980109125e-12,0.1552261588924274,855323.8565942126,1.505637305147768,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS730M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,730.0,695.4,3.08,,,22.0,18.34,49.7,17.68,41.3,0.007702800000000001,-0.11679500000000001,43.1,1.701101679942326,18.340003328401924,3.7574556980109125e-12,0.1552261588924274,855323.8565942126,1.505637305147768,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS735M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,735.0,700.3,3.08,,,22.0,18.38,49.9,17.72,41.5,0.0077196,-0.117265,43.1,1.7085525212205224,18.38000329055536,3.804834220834616e-12,0.15326772450181528,856109.0902663688,1.5927424798767993,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS735M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,735.0,700.3,3.08,,,22.0,18.38,49.9,17.72,41.5,0.0077196,-0.117265,43.1,1.7085525212205224,18.38000329055536,3.804834220834616e-12,0.15326772450181528,856109.0902663688,1.5927424798767993,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS740M13GFH-22/WNH,Phono Solar Technology Co Ltd,Mono-c-Si,0,740.0,705.2,3.08,,,22.0,18.42,50.1,17.76,41.7,0.007736400000000002,-0.11773499999999999,43.1,1.7160035393172297,18.420003252774173,3.852457164441664e-12,0.15131670811795805,856889.215965454,1.6791779269870923,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Phono Solar Technology Co Ltd PS740M13GFH-22/WNHB,Phono Solar Technology Co Ltd,Mono-c-Si,0,740.0,705.2,3.08,,,22.0,18.42,50.1,17.76,41.7,0.007736400000000002,-0.11773499999999999,43.1,1.7160035393172297,18.420003252774173,3.852457164441664e-12,0.15131670811795805,856889.215965454,1.6791779269870923,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +PowerShingle LLC EJ-410-PS-M10-B,PowerShingle LLC,Mono-c-Si,0,410.0,385.5,1.895,,,54.0,13.86,37.5,13.0,31.6,0.005544,-0.0915,45.0,1.3447468091968335,13.876070356177303,1.0483516743697102e-11,0.12645119800456525,109.05881645491915,8.940599252418519,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +PowerShingle LLC EJ-415-PS-M10-B,PowerShingle LLC,Mono-c-Si,0,415.0,386.4,1.94,,,54.0,13.69,38.0,12.9,32.2,0.0084878,-0.10108,46.5,1.4351028135720207,13.698655104543517,4.2606020831456456e-11,0.10176346717297427,160.9618774684622,11.701293235638518,-0.34,N,2025.7.3,6/23/2025,4.0,bootstrapping +PowerShingle LLC EJ-420-PS-M10-B,PowerShingle LLC,Mono-c-Si,0,420.0,391.2,1.94,,,54.0,13.71,38.3,12.89,32.6,0.0085002,-0.10187800000000001,46.5,1.451362237985893,13.718855356551744,4.6541989835238366e-11,0.08914190944011027,138.01088440113784,12.502617934782869,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +PowerShingle LLC EJ-425-PS-M10-B,PowerShingle LLC,Mono-c-Si,0,425.0,396.0,1.94,,,54.0,13.72,38.4,12.94,32.9,0.0085064,-0.10214400000000001,46.5,1.3973645546727047,13.727529886739843,1.5659180085553038e-11,0.08129585243909775,148.12694225478592,2.9575361008264114,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +PowerShingle LLC EJ-430-PS-M10-B,PowerShingle LLC,Mono-c-Si,0,430.0,400.8,1.94,,,54.0,13.74,38.6,12.99,33.1,0.0085188,-0.102676,46.5,1.4641870927542893,13.744774291384044,4.8165900432389716e-11,0.06883692167342498,198.10675095125794,12.774294586752832,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +PowerShingle LLC EJ-435-PS-M10-B,PowerShingle LLC,Mono-c-Si,0,435.0,405.6,1.94,,,54.0,13.76,38.7,13.02,33.4,0.0085312,-0.102942,46.5,1.4721392263912283,13.763350867041611,5.198860071982091e-11,0.05020941945496363,206.17996908298474,13.45965531300874,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-385HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,385.0,356.7,1.95,,,54.0,13.47,36.64,12.53,30.76,0.007085220000000001,-0.10618272000000001,45.15,1.4368158943991274,13.487355423279304,1.1007663456122617e-10,0.11553048769926705,89.66626549596326,10.934922442776733,-0.3762,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,390.0,362.0,1.95,,,54.0,13.59,36.72,12.64,30.88,0.0068765399999999996,-0.10465199999999998,45.15,1.426273745085523,13.607614024138039,8.689228694832253e-11,0.11253360518533845,86.82467347832339,10.635419086841749,-0.3692,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-390HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,390.0,361.5,1.95,,,54.0,13.59,36.72,12.64,30.88,0.0071483399999999996,-0.10641455999999999,45.15,1.4413852988563478,13.606914109729003,1.1387119940431283e-10,0.10989762960056478,88.2995811732779,11.160320117502444,-0.3762,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-395HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,395.0,366.8,1.95,,,54.0,13.71,36.83,12.73,31.04,0.00693726,-0.10496549999999999,45.15,1.4334980343447026,13.7279244319401,9.222716192603547e-11,0.10553175788251573,80.71889911920502,11.097750306891326,-0.3692,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-395HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,395.0,366.2,1.95,,,54.0,13.71,36.83,12.73,31.04,0.00721146,-0.10673334000000001,45.15,1.4487129986015548,13.727205053354602,1.208518196253221e-10,0.10289137830643567,81.98991214004029,11.62384571444851,-0.3762,N,2025.7.3,6/23/2025,2.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,400.0,371.5,1.95,,,54.0,13.82,36.94,12.85,31.13,0.0069929200000000006,-0.105279,45.15,1.4366577270555199,13.837233460098734,9.12719417441249e-11,0.10543266346536509,84.54944127909579,10.927089467138622,-0.3692,N,2025.7.3,6/23/2025,2.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-400HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,400.0,371.0,1.95,,,54.0,13.82,36.94,12.85,31.13,0.007269320000000001,-0.10705212,45.15,1.4518962807733164,13.836530684138218,1.1960469144022767e-10,0.10281389215243666,85.95457967801437,11.452839946128199,-0.3762,N,2025.7.3,6/23/2025,2.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-530HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,530.0,494.2,2.56,,,72.0,13.7,49.43,12.93,41.02,0.008603599999999998,-0.13756369,45.15,1.876619684497543,13.709887050199846,4.922503950167834e-11,0.20422577750291437,282.9856363256885,7.943165212468838,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-530HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,530.0,491.1,2.56,,,72.0,13.7,49.43,12.93,41.02,0.006466399999999999,-0.14082607,45.15,1.9128298741823424,13.70884142425341,8.112189766845476e-11,0.19812136279634143,306.993836156019,9.964853882642549,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-535HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,535.0,499.0,2.56,,,72.0,13.82,49.51,13.03,41.11,0.008678960000000001,-0.13778632999999998,45.15,1.8811611745752301,13.830875883504797,5.064960104122418e-11,0.20060339560687826,254.90701167289305,8.120889180378771,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-535HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,535.0,495.9,2.56,,,72.0,13.82,49.51,13.03,41.11,0.006523040000000001,-0.14105399,45.15,1.9174853597439376,13.829799878585444,8.346565765132387e-11,0.19452282032087648,274.3202804309529,10.144774381033791,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-540HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,540.0,503.7,2.56,,,72.0,13.94,49.68,13.11,41.21,0.00875432,-0.13825944,45.15,1.8889916944604879,13.953555603804626,5.192526012952214e-11,0.20296827090132918,208.72384434183982,8.272931837574852,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-540HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,540.0,500.6,2.56,,,72.0,13.94,49.68,13.11,41.21,0.00657968,-0.14153832,45.15,1.9254989532480782,13.952384204054043,8.557306650755989e-11,0.1968953753002527,221.63084327070553,10.29985645946009,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-545HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,545.0,508.5,2.56,,,72.0,13.99,49.76,13.21,41.3,0.008785719999999999,-0.13848207999999998,45.15,1.8888518269452201,13.999617312913468,5.0087098003292544e-11,0.20082895415625704,292.1395138726393,7.909934307851432,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-545HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,545.0,505.4,2.56,,,72.0,13.99,49.76,13.21,41.3,0.00660328,-0.14176624,45.15,1.92529158878298,13.998565208119096,8.25419262538751e-11,0.1948160251163068,318.2031557116548,9.931025375133784,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-550HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,550.0,513.3,2.56,,,72.0,14.06,49.82,13.31,41.38,0.00882968,-0.13864906000000002,45.15,1.8894839950540796,14.067132898729946,4.934040939279946e-11,0.19765436234054423,389.6060303071663,7.72503904612631,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-550HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,550.0,510.2,2.56,,,72.0,14.06,49.82,13.31,41.38,0.00663632,-0.14193718,45.15,1.9259008707194465,14.066158453649823,8.130873645894941e-11,0.1916905284684727,437.6389442088213,9.742894058574668,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,555.0,518.1,2.56,,,72.0,14.12,49.88,13.4,41.41,0.00886736,-0.13881604,45.15,1.8890051965902075,14.12475621675009,4.78236581829475e-11,0.19895616784029677,590.65037123018,7.405460992503585,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-555HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,555.0,515.0,2.56,,,72.0,14.12,49.88,13.4,41.41,0.0066646399999999995,-0.14210812,45.15,1.925363442142612,14.12384163801554,7.881462668883909e-11,0.19304722265571708,709.5481008312215,9.419148547666515,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-560HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,560.0,519.8,2.56,,,72.0,14.21,49.91,13.52,41.43,0.0067071200000000004,-0.14219358999999998,45.15,1.9239696741605958,14.211392857807995,7.687022749851311e-11,0.19258186281272924,1964.7314514067011,9.1319649443654,-0.3822,N,2025.7.3,6/23/2025,4.0,first_pass +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-645G12HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,645.0,595.6,3.11,,,66.0,18.26,45.15,17.3,37.29,0.0096778,-0.1270521,46.53,1.7314656254760077,18.267456207500675,8.589870484928326e-11,0.1489484258478035,364.7696734536507,9.203209681191602,-0.3735,N,2025.7.3,6/23/2025,4.0,bootstrapping +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-650G12HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,650.0,600.3,3.11,,,66.0,18.29,45.32,17.36,37.46,0.0096937,-0.12753048,46.53,1.7371548144115472,18.29499479869139,8.514975821470035e-11,0.14737458584022556,539.6576543830284,9.10416884248855,-0.3735,N,2025.7.3,6/23/2025,4.0,bootstrapping +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-655G12HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,655.0,605.1,3.11,,,66.0,18.32,45.54,17.4,37.65,0.0097096,-0.12814956,46.53,1.7452202935730383,18.324113516763045,8.488669151801701e-11,0.14733643206211122,656.1790790752273,9.059749129007969,-0.3735,N,2025.7.3,6/23/2025,4.0,bootstrapping +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-660G12HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,660.0,609.8,3.11,,,66.0,18.34,45.76,17.44,37.85,0.0097202,-0.12876864,46.53,1.7530587502196744,18.342519840325746,8.434851193872774e-11,0.1467422292963424,1068.0251387426224,8.989212704897017,-0.3735,N,2025.7.3,6/23/2025,4.0,bootstrapping +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-665G12HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,665.0,614.6,3.11,,,66.0,18.37,45.98,17.49,38.03,0.0097361,-0.12938771999999998,46.53,1.7603883351077878,18.370863538698444,8.324196023505068e-11,0.14739527606513836,3135.530866297883,8.853413198998584,-0.3735,N,2025.7.3,6/23/2025,4.0,bootstrapping +PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd PE-670G12HGB,PREMIER ENERGIES PHOTOVOLTAIC PRIVATE Ltd,Mono-c-Si,1,670.0,619.4,3.11,,,66.0,18.41,46.15,17.54,38.2,0.0097573,-0.1298661,46.53,1.7670199805499565,18.410035039488495,8.36353232523873e-11,0.14571399174351096,76559.69132889138,8.873156251640777,-0.3735,N,2025.7.3,6/23/2025,4.0,bootstrapping +Prism Solar Technologies Inc BN60-295,Prism Solar Technologies Inc,Mono-c-Si,1,295.0,274.1,1.653,,,60.0,9.77,40.11,9.15,32.24,0.004298799999999999,-0.11110470000000001,43.78,1.5150707421278413,9.786304611001572,3.053524505281037e-11,0.36131394749443047,216.50546143133232,7.497689179179613,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-333BSTC,Prism Solar Technologies Inc,Mono-c-Si,1,295.0,274.1,1.653,,,60.0,9.77,40.11,9.15,32.24,0.004298799999999999,-0.11110470000000001,43.78,1.5150707421278413,9.786304611001572,3.053524505281037e-11,0.36131394749443047,216.50546143133232,7.497689179179613,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-300,Prism Solar Technologies Inc,Mono-c-Si,1,300.0,278.9,1.653,,,60.0,9.91,40.45,9.24,32.48,0.0043604,-0.11204650000000002,43.78,1.5303554178594778,9.93164122232795,3.2143633130016645e-11,0.3636221702732,166.51073140250048,7.838010671869026,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-338BSTC,Prism Solar Technologies Inc,Mono-c-Si,1,300.0,278.9,1.653,,,60.0,9.91,40.45,9.24,32.48,0.0043604,-0.11204650000000002,43.78,1.5303554178594778,9.93164122232795,3.2143633130016645e-11,0.3636221702732,166.51073140250048,7.838010671869026,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-305,Prism Solar Technologies Inc,Mono-c-Si,1,305.0,283.6,1.653,,,60.0,10.06,40.79,9.32,32.73,0.0044264000000000005,-0.1129883,43.78,1.5474716944553926,10.089446674107261,3.4826151585336006e-11,0.3643607657690401,124.47821211606572,8.43227714425943,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-344BSTC,Prism Solar Technologies Inc,Mono-c-Si,1,305.0,283.6,1.653,,,60.0,10.06,40.79,9.32,32.73,0.0044264000000000005,-0.1129883,43.78,1.5474716944553926,10.089446674107261,3.4826151585336006e-11,0.3643607657690401,124.47821211606572,8.43227714425943,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-310,Prism Solar Technologies Inc,Mono-c-Si,1,310.0,288.4,1.653,,,60.0,10.21,41.14,9.4,32.97,0.0044924000000000006,-0.11395780000000001,43.78,1.5645459390254493,10.247591525162067,3.740599700190868e-11,0.3673964389914168,99.78625935615588,8.953840215073315,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN60-315,Prism Solar Technologies Inc,Mono-c-Si,1,315.0,293.2,1.653,,,60.0,10.37,41.49,9.48,33.22,0.0045628,-0.11492730000000002,43.78,1.582684792576457,10.417057119709582,4.0824037615453045e-11,0.3688126918991056,81.27543021056115,9.6153536861459,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BHC60-320,Prism Solar Technologies Inc,Mono-c-Si,1,320.0,298.2,1.644,,,60.0,10.06,40.21,9.73,32.96,0.0038228000000000003,-0.11138170000000001,44.45,1.4952550452093416,10.060002213500937,2.1070018997755358e-11,0.21996161554985105,999721.8198515422,4.093006768517801,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc BN60-320,Prism Solar Technologies Inc,Mono-c-Si,1,320.0,297.9,1.653,,,60.0,10.52,41.84,9.56,33.47,0.0046288,-0.11589680000000002,43.78,1.600099300244771,10.575517308265056,4.3955758631766524e-11,0.3705051373405951,70.2071876014965,10.166091875340946,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BHC60-325,Prism Solar Technologies Inc,Mono-c-Si,1,325.0,302.9,1.644,,,60.0,10.15,40.3,9.82,33.1,0.003857,-0.11163100000000001,44.45,1.5000892108737318,10.150002130252814,2.183299076272701e-11,0.20981113214892608,999717.6365649508,4.317666491531707,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc BHC60-330,Prism Solar Technologies Inc,Mono-c-Si,1,330.0,307.7,1.644,,,60.0,10.25,40.39,9.93,33.24,0.003895,-0.11188030000000002,44.45,1.505600236149038,10.250001993194362,2.2914844575071865e-11,0.1943974942575738,999720.5398948791,4.643334612173405,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc BHC60-335,Prism Solar Technologies Inc,Mono-c-Si,1,335.0,312.5,1.644,,,60.0,10.34,40.46,10.03,33.4,0.0039292,-0.11207420000000001,44.45,1.511049217669503,10.340001815242365,2.4311282107049894e-11,0.17550218881964869,999728.2062224059,5.07054967083592,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc BHC60-340,Prism Solar Technologies Inc,Mono-c-Si,1,340.0,317.3,1.644,,,60.0,10.43,40.6,10.11,33.62,0.0039634,-0.11246200000000002,44.45,1.5178412693958554,10.430001745580784,2.5208686392635928e-11,0.16731003414636264,999723.3796200273,5.304968512367707,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc PST-345W-m60H,Prism Solar Technologies Inc,Mono-c-Si,0,345.0,322.3,1.84,,,60.0,10.53,41.25,10.03,34.39,0.005991569999999999,-0.11389125000000001,43.8,1.5584147655749834,10.531092145026673,3.358793842727691e-11,0.20527383880763123,1979.16363619847,7.806695296151971,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-345W-m60HB,Prism Solar Technologies Inc,Mono-c-Si,0,345.0,321.9,1.84,,,60.0,10.53,41.25,10.03,34.39,0.00616005,-0.12742125,43.9,1.5787918936919714,10.5307040045344,4.7296614069288905e-11,0.20082958348517294,3003.8668933084123,-1.0417211689411352,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-345W-m60HBi,Prism Solar Technologies Inc,Mono-c-Si,1,345.0,322.1,1.84,,,60.0,10.53,41.25,10.03,34.39,0.00462267,-0.1215225,43.8,1.5477539683900705,10.531301854060326,2.7980703164282417e-11,0.20760770336044077,1679.2275928616612,-0.3257612591984272,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-350W-m60H,Prism Solar Technologies Inc,Mono-c-Si,0,350.0,327.1,1.84,,,60.0,10.59,41.4,10.06,34.79,0.006025709999999999,-0.1143054,43.8,1.5725263060899102,10.592840284630766,3.878612270652644e-11,0.17311799510851908,645.4703882944182,9.034184962399278,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-350W-m60HB,Prism Solar Technologies Inc,Mono-c-Si,0,350.0,326.7,1.84,,,60.0,10.59,41.4,10.06,34.79,0.00619515,-0.1278846,43.9,1.5934157272289622,10.592460346352876,5.4808294232334006e-11,0.16854699245635907,725.4721393986703,0.11122169646889436,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-350W-m60HBi,Prism Solar Technologies Inc,Mono-c-Si,1,350.0,326.9,1.84,,,60.0,10.59,41.4,10.06,34.79,0.00464901,-0.12196439999999999,43.8,1.5618611089638457,10.593040929415057,3.239368264622656e-11,0.175460548462941,611.0392579757236,0.8281823936151946,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-355W-m60H,Prism Solar Technologies Inc,Mono-c-Si,0,355.0,331.8,1.84,,,60.0,10.63,41.6,10.1,35.14,0.00604847,-0.11485760000000002,43.8,1.58418694323585,10.632606300786312,4.16421772783151e-11,0.1526063134462177,622.4167090353914,9.630494114976107,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-355W-m60HB,Prism Solar Technologies Inc,Mono-c-Si,0,355.0,331.4,1.84,,,60.0,10.63,41.6,10.1,35.14,0.006218550000000001,-0.12850240000000002,43.9,1.6053928637719028,10.632260392593455,5.894559672488682e-11,0.1479676332310073,695.8508066451592,0.6719426572250132,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-355W-m60HBi,Prism Solar Technologies Inc,Mono-c-Si,1,355.0,331.7,1.84,,,60.0,10.63,41.6,10.1,35.14,0.00466657,-0.1225536,43.8,1.5734903881651112,10.632787401562478,3.482313243803032e-11,0.15495496786291527,590.9343551677294,1.3888968197357725,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-360,Prism Solar Technologies Inc,Mono-c-Si,1,360.0,334.7,1.969,,,72.0,9.99,47.56,9.32,38.63,0.0043955999999999995,-0.13174120000000003,43.78,1.8098098242342322,10.009222267172992,3.7729343957614494e-11,0.36905506780165304,191.801525929123,9.174135608542356,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-429BSTC,Prism Solar Technologies Inc,Mono-c-Si,1,360.0,334.7,1.969,,,72.0,9.99,47.56,9.32,38.63,0.0043955999999999995,-0.13174120000000003,43.78,1.8098098242342322,10.009222267172992,3.7729343957614494e-11,0.36905506780165304,191.801525929123,9.174135608542356,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-360W-m60H,Prism Solar Technologies Inc,Mono-c-Si,0,360.0,336.6,1.84,,,60.0,11.24,41.8,10.23,35.19,0.00639556,-0.1154098,43.8,1.624810180241933,11.266136035228971,7.135961482391429e-11,0.15056060863872167,64.74973089779319,14.177283501976222,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-360W-m60HB,Prism Solar Technologies Inc,Mono-c-Si,0,360.0,336.2,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0065754,-0.1291202,43.9,1.647799265926316,11.264976095563732,1.0223137341234119e-10,0.14555818422640596,65.50559505620262,4.937568070973225,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-360W-m60HBi,Prism Solar Technologies Inc,Mono-c-Si,1,360.0,336.5,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0049343600000000005,-0.12314279999999998,43.8,1.6143710749462203,11.26667103590045,6.040727023587574e-11,0.15284083591743033,64.41185897355605,5.694412837985603,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-365,Prism Solar Technologies Inc,Mono-c-Si,1,365.0,339.5,1.969,,,72.0,10.08,47.66,9.43,38.71,0.004435199999999999,-0.1320182,43.78,1.8111252042027433,10.096688787366835,3.6838871099786216e-11,0.3667028216080695,221.487901739539,8.873509268724197,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-435BSTC,Prism Solar Technologies Inc,Mono-c-Si,1,365.0,339.5,1.969,,,72.0,10.08,47.66,9.43,38.71,0.004435199999999999,-0.1320182,43.78,1.8111252042027433,10.096688787366835,3.6838871099786216e-11,0.3667028216080695,221.487901739539,8.873509268724197,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc P72-365,Prism Solar Technologies Inc,Mono-c-Si,0,365.0,336.2,1.91,,,72.0,9.705,48.05,9.236,39.52,0.00436725,-0.13454000000000002,46.43,1.8220667901773082,9.705007073503133,3.420938479722476e-11,0.32224034727670414,442130.5181361292,7.302764298598712,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-365W-m60H,Prism Solar Technologies Inc,Mono-c-Si,0,365.0,341.4,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0064297,-0.115962,43.8,1.6279961137227528,11.324537698439016,6.707982110566852e-11,0.15453245804335491,71.16465260224258,13.540874505351042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-365W-m60HB,Prism Solar Technologies Inc,Mono-c-Si,0,365.0,341.0,1.84,,,60.0,11.3,42.0,10.33,35.33,0.006610500000000001,-0.129738,43.9,1.6508546900057997,11.323455053150314,9.593789047779915e-11,0.1496146493374621,72.08022675703677,4.3396540493048095,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-365W-m60HBi,Prism Solar Technologies Inc,Mono-c-Si,1,365.0,341.3,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0049607,-0.12373199999999998,43.8,1.6174541226173103,11.32504521912303,5.6682304177878583e-11,0.15680912308680353,70.74975428077438,5.090868735469773,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-370,Prism Solar Technologies Inc,Mono-c-Si,1,370.0,344.2,1.969,,,72.0,10.17,47.75,9.54,38.78,0.004474799999999999,-0.1322675,43.78,1.812074467258471,10.184158871832455,3.597309230456775e-11,0.36453194772625663,261.83512469623605,8.575407810537381,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-441BSTC,Prism Solar Technologies Inc,Mono-c-Si,1,370.0,344.2,1.969,,,72.0,10.17,47.75,9.54,38.78,0.004474799999999999,-0.1322675,43.78,1.812074467258471,10.184158871832455,3.597309230456775e-11,0.36453194772625663,261.83512469623605,8.575407810537381,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc P72-370,Prism Solar Technologies Inc,Mono-c-Si,0,370.0,341.0,1.91,,,72.0,9.767,48.08,9.323,39.69,0.00439515,-0.13462400000000002,46.43,1.8284585595021627,9.767003975277762,3.7138387855543376e-11,0.3016178316965489,741083.0172983615,7.961301128204087,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-370W-m60H,Prism Solar Technologies Inc,Mono-c-Si,0,370.0,346.2,1.84,,,60.0,11.36,42.2,10.45,35.4,0.006463839999999999,-0.11651420000000001,43.8,1.6278813277492246,11.382761958473912,5.999208639221643e-11,0.16649289807193457,83.09299637870247,12.445711814615798,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-370W-m60HB,Prism Solar Technologies Inc,Mono-c-Si,0,370.0,345.8,1.84,,,60.0,11.36,42.2,10.45,35.4,0.0066456,-0.13035580000000002,43.9,1.6504353567811691,11.381779156463201,8.554753600302316e-11,0.16171298513118007,84.34943423732544,3.31054810904644,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-370W-m60HBi,Prism Solar Technologies Inc,Mono-c-Si,1,370.0,346.0,1.84,,,60.0,11.36,42.2,10.45,35.4,0.00498704,-0.1243212,43.8,1.6172082503039238,11.383235182170656,5.0543836988284634e-11,0.16876347395881114,82.51078281019736,4.053954503994833,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-375,Prism Solar Technologies Inc,Mono-c-Si,1,375.0,349.0,1.969,,,72.0,10.26,47.85,9.65,38.86,0.0045144,-0.1325445,43.78,1.8135070377307068,10.271620540761152,3.5177019459858046e-11,0.3622359539544312,319.82513034029927,8.291226056420347,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc P72-375,Prism Solar Technologies Inc,Mono-c-Si,0,375.0,345.7,1.91,,,72.0,9.826,48.16,9.432,39.76,0.004421700000000001,-0.134848,46.43,1.8361139913428868,9.826002598424173,3.9914516788745766e-11,0.26442748171257524,999986.4044316196,8.538534619527118,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc P72X-375,Prism Solar Technologies Inc,Mono-c-Si,0,375.0,346.5,1.96,,,72.0,9.939,48.02,9.36,40.06,0.00427377,-0.13157480000000002,45.98,1.8295852851665884,9.947089407694262,3.909162110898632e-11,0.2474223856219304,303.99396560604,10.725216825409367,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-380,Prism Solar Technologies Inc,Mono-c-Si,1,380.0,353.8,1.969,,,72.0,10.35,47.94,9.76,38.94,0.004554,-0.13279380000000002,43.78,1.814812969569242,10.359074096450595,3.4521088550757016e-11,0.3589291913248221,409.39802963989877,8.039684860219491,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc P72-380,Prism Solar Technologies Inc,Mono-c-Si,0,380.0,350.5,1.91,,,72.0,9.904,48.17,9.552,39.78,0.0044568,-0.13487600000000002,46.43,1.8411259437973795,9.904192741075986,4.295855733492039e-11,0.23339223873863194,11992.866436480099,9.115939059407328,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc P72X-380,Prism Solar Technologies Inc,Mono-c-Si,0,380.0,351.2,1.96,,,72.0,9.966,48.31,9.385,40.49,0.004285379999999999,-0.13236940000000003,45.98,1.8451355243977439,9.973559875826561,4.1768535587064255e-11,0.2251152869369025,296.76399857611653,11.296250200440094,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc P72X-385,Prism Solar Technologies Inc,Mono-c-Si,0,385.0,356.0,1.96,,,72.0,9.993,48.53,9.426,40.84,0.00429699,-0.1329722,45.98,1.8559119213283715,9.999200155035059,4.337566344869701e-11,0.2055610925789771,331.3097842914617,11.605594099095624,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BHC72-390,Prism Solar Technologies Inc,Mono-c-Si,1,390.0,363.6,1.95,,,72.0,10.14,48.17,9.84,39.65,0.0038532,-0.13343090000000002,44.45,1.7970699724211436,10.140002345148586,2.316773844656477e-11,0.2228910642067499,963764.020759788,4.827585670982573,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc P72X-390,Prism Solar Technologies Inc,Mono-c-Si,0,390.0,360.7,1.96,,,72.0,10.024,48.96,9.499,41.05,0.004310319999999999,-0.13415040000000003,45.98,1.8644884653531852,10.02804498405897,3.919069428909623e-11,0.22603626182634262,560.1474585725583,10.646037046790884,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BHC72-395,Prism Solar Technologies Inc,Mono-c-Si,1,395.0,368.4,1.95,,,72.0,10.23,48.26,9.92,39.83,0.0038874,-0.1336802,44.45,1.801919415341224,10.230002281142552,2.3897868277476244e-11,0.2146515641432144,962648.5861476725,5.015753259162963,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc P72X-395,Prism Solar Technologies Inc,Mono-c-Si,0,395.0,365.5,1.96,,,72.0,10.045,49.28,9.532,41.44,0.00431935,-0.13502720000000001,45.98,1.8782400476833687,10.04818007218903,4.019544233202464e-11,0.2125641557348506,671.4335004254732,10.848483639252144,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BHC72-400,Prism Solar Technologies Inc,Mono-c-Si,1,400.0,373.2,1.95,,,72.0,10.32,48.35,10.0,40.01,0.0039216,-0.13392950000000003,44.45,1.8067736059518615,10.320002215078171,2.464789706876251e-11,0.20639131996084753,961595.9445654469,5.203819678830192,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc P72X-400,Prism Solar Technologies Inc,Mono-c-Si,0,400.0,370.2,1.96,,,72.0,10.067,49.46,9.61,41.62,0.00432881,-0.1355204,45.98,1.8802442234439374,10.06703608400794,3.790603515475459e-11,0.21049894661091498,58726.69092346412,10.278995480638027,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BHC72-405,Prism Solar Technologies Inc,Mono-c-Si,1,405.0,378.0,1.95,,,72.0,10.42,48.45,10.08,40.19,0.0039596,-0.13420650000000003,44.45,1.811087725630039,10.420002220586541,2.509991223508437e-11,0.20449122130429792,959589.2665693868,5.276345861294407,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc BHC72-410,Prism Solar Technologies Inc,Mono-c-Si,1,410.0,382.8,1.95,,,72.0,10.51,48.56,10.16,40.38,0.0039938,-0.13451120000000003,44.45,1.8165742789764594,10.510002157568573,2.583445334880758e-11,0.19680445371983707,958702.2857221005,5.448671170857095,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc BHC72-415,Prism Solar Technologies Inc,Mono-c-Si,1,415.0,387.6,1.95,,,72.0,10.61,48.64,10.25,40.5,0.0040318,-0.1347328,44.45,1.820092753883523,10.610002143409845,2.6282431236087076e-11,0.19332734024384224,957005.0950688091,5.514470894218182,-0.36,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc PST-415W-M72h,Prism Solar Technologies Inc,Mono-c-Si,0,415.0,387.7,2.21,,,72.0,11.23,49.6,10.08,41.15,0.006389870000000001,-0.13694560000000003,43.8,1.9271730242120406,11.275835023557631,6.944384325500057e-11,0.24537088518324618,60.11811118537737,13.981645867970887,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-415W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,415.0,387.3,2.21,,,72.0,11.23,49.6,10.08,41.15,0.0049299700000000005,-0.1461216,43.9,1.9147971237492492,11.276538175890673,5.87862246434601e-11,0.2480946212605528,59.86703508387783,5.515747616238673,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-415W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,415.0,387.5,2.21,,,72.0,11.23,49.6,10.08,41.15,0.0049299700000000005,-0.1461216,43.8,1.9147971237492492,11.276538175890673,5.87862246434601e-11,0.2480946212605528,59.86703508387783,5.515747616238673,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-420W-m72H,Prism Solar Technologies Inc,Mono-c-Si,0,420.0,392.5,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00641263,-0.1374978,43.8,1.924275612696981,11.31293592026113,6.09726878700558e-11,0.2600136617475694,68.24947421628364,12.727371690319782,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-420W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,420.0,392.0,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00659295,-0.1538322,43.9,1.951007151081974,11.311542692840815,8.697378039427566e-11,0.25423863398445407,68.97168260170793,3.5691810931519705,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-420W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,420.0,392.3,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00494753,-0.14671079999999997,43.8,1.9117347014768715,11.31359838481594,5.143806616521304e-11,0.262733302133244,67.91545931249719,4.327504679843871,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-425W,Prism Solar Technologies Inc,Mono-c-Si,1,425.0,398.1,2.25,,,72.0,11.19,48.85,10.71,39.71,0.00398364,-0.12950135000000002,43.5,1.7663257838461437,11.190006087970051,1.0910827381310195e-11,0.34913148512999825,641730.833210454,2.2842053717504154,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-425W-m72H,Prism Solar Technologies Inc,Mono-c-Si,0,425.0,397.2,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00642401,-0.13805,43.8,1.920119686782371,11.32762249190583,5.26150851471865e-11,0.27379873355090534,82.16329012473263,11.33962396657383,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-425W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,425.0,396.8,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00660465,-0.15445,43.9,1.946344078921541,11.326390454424786,7.477315224594048e-11,0.26821651782241673,83.21315458114935,2.2662306913522463,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-425W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,425.0,397.0,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00495631,-0.1473,43.8,1.9074184082751062,11.3282278351693,4.422606743127526e-11,0.2765126468710977,81.66373491573208,3.0145851067784473,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-430W,Prism Solar Technologies Inc,Mono-c-Si,1,430.0,402.9,2.25,,,72.0,11.24,49.0,10.75,40.01,0.00400144,-0.129899,43.5,1.774505185261158,11.240005909805564,1.1440526406541307e-11,0.32995096267800206,627550.2035863111,2.6418373699041884,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-430W-m72H,Prism Solar Technologies Inc,Mono-c-Si,0,430.0,402.0,2.21,,,72.0,11.3,50.2,10.36,41.51,0.0064297,-0.1386022,43.8,1.9249664106109183,11.332475061769282,5.0969066282848636e-11,0.2657101017137451,92.4563034329522,11.027510616055379,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-430W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,430.0,401.5,2.21,,,72.0,11.3,50.2,10.36,41.51,0.006610500000000001,-0.1550678,43.9,1.9511598594549733,11.331348435421756,7.237893153737509e-11,0.2601647733633265,93.78018146089012,1.9743736468362443,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-430W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,430.0,401.8,2.21,,,72.0,11.3,50.2,10.36,41.51,0.0049607,-0.1478892,43.8,1.9121862296374148,11.333033207741956,4.280383197557569e-11,0.2684260255751194,91.82317754589283,2.71827473914128,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc BN72-435W,Prism Solar Technologies Inc,Mono-c-Si,1,435.0,407.7,2.25,,,72.0,11.29,49.15,10.79,40.31,0.00401924,-0.13029664999999999,43.5,1.7826827073596554,11.290005711990347,1.1990628694549686e-11,0.31092655513541373,614567.9376193149,2.997048798771249,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-435W-m72H,Prism Solar Technologies Inc,Mono-c-Si,0,435.0,406.8,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00643539,-0.13901635,43.8,1.924568686057769,11.336738709564765,4.731420417143629e-11,0.26420393433870276,111.75358010691457,10.326639687995666,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-435W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,435.0,406.3,2.21,,,72.0,11.31,50.35,10.44,41.66,0.006616350000000001,-0.15553115000000003,43.9,1.9505326261159281,11.335741569257468,6.706531849378671e-11,0.2587554721796313,113.68865618248695,1.3174222295105524,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-435W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,435.0,406.6,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00496509,-0.1483311,43.8,1.9117002752017433,11.337241145805205,3.9662350734410156e-11,0.2669145689428395,110.81779668211968,2.0553314445877207,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-440W-M60H-M10,Prism Solar Technologies Inc,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-440W-m72H,Prism Solar Technologies Inc,Mono-c-Si,0,440.0,411.6,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00645246,-0.1394305,43.8,1.9124794349887924,11.363041723554051,3.738174534735004e-11,0.26483785869404597,130.34013402256596,8.20169258294452,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-440W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,440.0,411.1,2.21,,,72.0,11.34,50.5,10.52,41.81,0.006633900000000001,-0.1559945,43.9,1.9518542605852915,11.361652353741434,6.373939404646147e-11,0.2566328218030774,134.40646053918988,0.8629499066944296,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-440W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,440.0,411.4,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00497826,-0.148773,43.8,1.9130868303524184,11.363019910950262,3.7697003654815584e-11,0.26471080823934795,130.40105109924505,1.5968095271374523,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-445W-M60H-M10,Prism Solar Technologies Inc,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc PST-445W-m72H,Prism Solar Technologies Inc,Mono-c-Si,0,445.0,416.4,2.21,,,72.0,11.37,50.58,10.61,41.96,0.006469529999999999,-0.13965138000000002,43.8,1.9253852741335864,11.387332575414236,4.3222162224326944e-11,0.2532351485909144,166.11978286616585,9.432638289090042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-445W-m72HB,Prism Solar Technologies Inc,Mono-c-Si,0,445.0,415.9,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00665145,-0.15624162000000003,43.9,1.9510767268211706,11.386540933617326,6.112345888567276e-11,0.24793320976451697,170.42572651439679,0.4803109068239914,-0.3593,N,2025.7.3,6/23/2025,4.0,bootstrapping +Prism Solar Technologies Inc PST-445W-m72HBi,Prism Solar Technologies Inc,Mono-c-Si,1,445.0,416.2,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00499143,-0.14900868,43.8,1.9123979902602979,11.387740649298621,3.614853084898033e-11,0.2559254641843815,164.02288890230403,1.209671200758284,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-450W-M60H-M10,Prism Solar Technologies Inc,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Prism Solar Technologies Inc PST-530W-M72H-M10,Prism Solar Technologies Inc,Mono-c-Si,0,530.0,496.5,2.56,,,74.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc PST-535W-M72H-M10,Prism Solar Technologies Inc,Mono-c-Si,0,535.0,501.3,2.56,,,74.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Prism Solar Technologies Inc PST-540W-M72H-M10,Prism Solar Technologies Inc,Mono-c-Si,0,540.0,506.1,2.56,,,74.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA120H-310M,PT IDN SOLAR TECH,Mono-c-Si,0,310.0,288.9,1.69,,,60.0,9.87,39.8,9.37,33.1,0.00448098,-0.12708139999999998,43.1,1.5377292914628005,9.872457490116586,5.647116527576378e-11,0.21312836566898127,855.9859473483768,-2.2214407539941066,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-310MB,PT IDN SOLAR TECH,Mono-c-Si,0,310.0,288.9,1.69,,,60.0,9.87,39.8,9.37,33.1,0.00448098,-0.12708139999999998,43.1,1.5377292914628005,9.872457490116586,5.647116527576378e-11,0.21312836566898127,855.9859473483768,-2.2214407539941066,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-315M,PT IDN SOLAR TECH,Mono-c-Si,0,315.0,293.6,1.69,,,60.0,9.95,40.1,9.44,33.4,0.0045173,-0.1280393,43.1,1.5510781170658274,9.95287763568422,5.85713310498649e-11,0.2067427880417301,714.8545133233855,-1.994191712987097,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-315MB,PT IDN SOLAR TECH,Mono-c-Si,0,315.0,293.6,1.69,,,60.0,9.95,40.1,9.44,33.4,0.0045173,-0.1280393,43.1,1.5510781170658274,9.95287763568422,5.85713310498649e-11,0.2067427880417301,714.8545133233855,-1.994191712987097,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-320M,PT IDN SOLAR TECH,Mono-c-Si,0,320.0,298.4,1.69,,,60.0,10.01,40.4,9.52,33.6,0.00454454,-0.12899719999999998,43.1,1.5594806694762098,10.011318481918758,5.6046597497040173e-11,0.21340412336309736,1620.1778500561127,-2.3985223376509746,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-320MB,PT IDN SOLAR TECH,Mono-c-Si,0,320.0,298.4,1.69,,,60.0,10.01,40.4,9.52,33.6,0.00454454,-0.12899719999999998,43.1,1.5594806694762098,10.011318481918758,5.6046597497040173e-11,0.21340412336309736,1620.1778500561127,-2.3985223376509746,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-325M,PT IDN SOLAR TECH,Mono-c-Si,0,325.0,303.2,1.69,,,60.0,10.08,40.7,9.59,33.9,0.00457632,-0.1299551,43.1,1.572068671654508,10.081138844540812,5.739927918229155e-11,0.20743500865316442,1836.023389196733,-2.266540433735232,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-325MB,PT IDN SOLAR TECH,Mono-c-Si,0,325.0,303.2,1.69,,,60.0,10.08,40.7,9.59,33.9,0.00457632,-0.1299551,43.1,1.572068671654508,10.081138844540812,5.739927918229155e-11,0.20743500865316442,1836.023389196733,-2.266540433735232,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-330M,PT IDN SOLAR TECH,Mono-c-Si,0,330.0,308.0,1.69,,,60.0,10.16,41.0,9.66,34.2,0.00461264,-0.130913,43.1,1.5854106485743296,10.161584848683233,5.948328472029257e-11,0.2012402066467556,1290.0920591164763,-2.0447947683240764,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-330MB,PT IDN SOLAR TECH,Mono-c-Si,0,330.0,308.0,1.69,,,60.0,10.16,41.0,9.66,34.2,0.00461264,-0.130913,43.1,1.5854106485743296,10.161584848683233,5.948328472029257e-11,0.2012402066467556,1290.0920591164763,-2.0447947683240764,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-335M,PT IDN SOLAR TECH,Mono-c-Si,0,335.0,312.8,1.69,,,60.0,10.35,41.2,9.75,34.4,0.0046989,-0.1315516,43.1,1.6015741594267747,10.357332239048255,6.867210639127111e-11,0.19335090406732497,272.92916227161095,-1.0167775131842502,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-335MB,PT IDN SOLAR TECH,Mono-c-Si,0,335.0,312.8,1.69,,,60.0,10.35,41.2,9.75,34.4,0.0046989,-0.1315516,43.1,1.6015741594267747,10.357332239048255,6.867210639127111e-11,0.19335090406732497,272.92916227161095,-1.0167775131842502,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-340M,PT IDN SOLAR TECH,Mono-c-Si,0,340.0,317.6,1.69,,,60.0,10.44,41.4,9.82,34.6,0.00473976,-0.13219019999999998,43.1,1.6114484560287263,10.4481896768571,7.149664242845417e-11,0.18850236581711358,240.298216216177,-0.7580831431574077,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-340MB,PT IDN SOLAR TECH,Mono-c-Si,0,340.0,317.6,1.69,,,60.0,10.44,41.4,9.82,34.6,0.00473976,-0.13219019999999998,43.1,1.6114484560287263,10.4481896768571,7.149664242845417e-11,0.18850236581711358,240.298216216177,-0.7580831431574077,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-350M,PT IDN SOLAR TECH,Mono-c-Si,0,350.0,326.6,1.82,,,60.0,11.01,41.1,10.42,33.6,0.00742074,-0.1156965,43.2,1.591840883293153,11.014763101425208,6.70089661089196e-11,0.2583585858951836,597.2008520298954,11.275384061479969,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-355M,PT IDN SOLAR TECH,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007467920000000001,-0.11625949999999999,43.2,1.5987418878060913,11.082655311072475,6.66908404780848e-11,0.254018124528891,1059.959109625431,11.16681125367441,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-355MB,PT IDN SOLAR TECH,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007467920000000001,-0.11625949999999999,43.2,1.5987418878060913,11.082655311072475,6.66908404780848e-11,0.254018124528891,1059.959109625431,11.16681125367441,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-360M,PT IDN SOLAR TECH,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.0075151,-0.1168225,43.2,1.6063866847452126,11.151507243277342,6.710118392710772e-11,0.24971156911102335,1847.2692831374839,11.160560710349037,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-360MB,PT IDN SOLAR TECH,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.0075151,-0.1168225,43.2,1.6063866847452126,11.151507243277342,6.710118392710772e-11,0.24971156911102335,1847.2692831374839,11.160560710349037,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-365M,PT IDN SOLAR TECH,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007562280000000001,-0.1173855,43.2,1.6140377871100615,11.220004328233308,6.755129283530156e-11,0.2453763124568138,636129.253602014,11.157966857761727,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-365MB,PT IDN SOLAR TECH,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007562280000000001,-0.1173855,43.2,1.6140377871100615,11.220004328233308,6.755129283530156e-11,0.2453763124568138,636129.253602014,11.157966857761727,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-365MD,PT IDN SOLAR TECH,Mono-c-Si,0,365.0,342.0,1.72,,,60.0,11.22,41.7,10.68,34.2,0.005632440000000001,-0.11771910000000001,43.4,1.5688488062697814,11.220684169938782,3.2069000828562285e-11,0.2544664457993554,4173.106612001741,4.571002439654092,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-370M,PT IDN SOLAR TECH,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.00760946,-0.11794849999999998,43.2,1.623333945636469,11.290004300440746,6.967589700101727e-11,0.24090660789441073,632499.5698948535,11.380881482322765,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-370MB,PT IDN SOLAR TECH,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.00760946,-0.11794849999999998,43.2,1.623333945636469,11.290004300440746,6.967589700101727e-11,0.24090660789441073,632499.5698948535,11.380881482322765,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-370MD,PT IDN SOLAR TECH,Mono-c-Si,0,370.0,346.8,1.72,,,60.0,11.29,41.9,10.76,34.4,0.00566758,-0.11828369999999999,43.4,1.576917863189026,11.290004477461862,3.259351850041352e-11,0.2501562456680945,630796.3665573923,4.652800091753175,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-370M,PT IDN SOLAR TECH,Mono-c-Si,0,370.0,344.8,2.01,,,72.0,9.91,48.1,9.31,39.7,0.00449914,-0.1535833,43.1,1.8607071467439353,9.920127898074627,5.7865894639737154e-11,0.29275157178511246,286.4531333107678,-2.0244921401432587,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-370MB,PT IDN SOLAR TECH,Mono-c-Si,0,370.0,344.8,2.01,,,72.0,9.91,48.1,9.31,39.7,0.00449914,-0.1535833,43.1,1.8607071467439353,9.920127898074627,5.7865894639737154e-11,0.29275157178511246,286.4531333107678,-2.0244921401432587,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-375M,PT IDN SOLAR TECH,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.007656639999999999,-0.1185115,43.2,1.6326281749146987,11.36000427162938,7.184212125694039e-11,0.2365031656918171,629002.3785413279,11.601406904317031,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-375MB,PT IDN SOLAR TECH,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.007656639999999999,-0.1185115,43.2,1.6326281749146987,11.36000427162938,7.184212125694039e-11,0.2365031656918171,629002.3785413279,11.601406904317031,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-375MD,PT IDN SOLAR TECH,Mono-c-Si,0,375.0,351.6,1.72,,,60.0,11.36,42.1,10.84,34.6,0.00570272,-0.1188483,43.4,1.585961674843159,11.36000445052144,3.36396638747458e-11,0.24573436125648168,627262.2089074068,4.868180250991331,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-375M,PT IDN SOLAR TECH,Mono-c-Si,0,375.0,349.6,2.01,,,72.0,9.95,48.3,9.37,40.0,0.0045173,-0.1542219,43.1,1.8695803247296943,9.958091400230385,5.916647320584644e-11,0.27633477485159036,339.8090492690494,-1.8883607903109203,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-375MB,PT IDN SOLAR TECH,Mono-c-Si,0,375.0,349.6,2.01,,,72.0,9.95,48.3,9.37,40.0,0.0045173,-0.1542219,43.1,1.8695803247296943,9.958091400230385,5.916647320584644e-11,0.27633477485159036,339.8090492690494,-1.8883607903109203,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-380M,PT IDN SOLAR TECH,Mono-c-Si,0,380.0,354.4,2.01,,,72.0,10.0,48.5,9.42,40.3,0.004540000000000001,-0.15486049999999998,43.1,1.8804411979082738,10.007601149797864,6.206944526068546e-11,0.2595838137674135,341.5059918298911,-1.5487228434747504,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-380MB,PT IDN SOLAR TECH,Mono-c-Si,0,380.0,354.4,2.01,,,72.0,10.0,48.5,9.42,40.3,0.004540000000000001,-0.15486049999999998,43.1,1.8804411979082738,10.007601149797864,6.206944526068546e-11,0.2595838137674135,341.5059918298911,-1.5487228434747504,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-385M,PT IDN SOLAR TECH,Mono-c-Si,0,385.0,359.1,2.01,,,72.0,10.06,48.7,9.49,40.6,0.004567240000000001,-0.1554991,43.1,1.8901873336351411,10.066436854912785,6.424882726288e-11,0.24296285097227624,379.7205760801304,-1.3263701613996557,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-385MB,PT IDN SOLAR TECH,Mono-c-Si,0,385.0,359.1,2.01,,,72.0,10.06,48.7,9.49,40.6,0.004567240000000001,-0.1554991,43.1,1.8901873336351411,10.066436854912785,6.424882726288e-11,0.24296285097227624,379.7205760801304,-1.3263701613996557,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-390MT,PT IDN SOLAR TECH,Mono-c-Si,0,390.0,367.1,1.95,,,54.0,13.61,36.85,12.73,30.64,0.00547122,-0.1053173,43.1,1.3528139552002494,13.63038851974695,1.9640700099785117e-11,0.15660887636592763,104.54151859762304,-2.068521711240506,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-390M,PT IDN SOLAR TECH,Mono-c-Si,0,390.0,363.9,2.01,,,72.0,10.12,49.0,9.55,40.8,0.004594480000000001,-0.15645699999999998,43.1,1.9002161783524452,10.126354147256425,6.326632942465255e-11,0.24914720067083385,396.80692010098596,-1.4977676251362664,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-390MB,PT IDN SOLAR TECH,Mono-c-Si,0,390.0,363.9,2.01,,,72.0,10.12,49.0,9.55,40.8,0.004594480000000001,-0.15645699999999998,43.1,1.9002161783524452,10.126354147256425,6.326632942465255e-11,0.24914720067083385,396.80692010098596,-1.4977676251362664,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108-395MB,PT IDN SOLAR TECH,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-395M,PT IDN SOLAR TECH,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-395MB,PT IDN SOLAR TECH,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-395MT,PT IDN SOLAR TECH,Mono-c-Si,0,395.0,371.9,1.95,,,54.0,13.7,36.98,12.81,30.84,0.005507399999999999,-0.10568883999999999,43.1,1.3599071000982348,13.719889796586346,2.069746410184593e-11,0.14785558331393842,101.84226085027892,-1.7016048868222151,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-395M,PT IDN SOLAR TECH,Mono-c-Si,0,395.0,368.7,2.01,,,72.0,10.19,49.2,9.62,41.1,0.00462626,-0.1570956,43.1,1.9109351229196812,10.195881545390199,6.631346076782714e-11,0.23243490950701315,402.7022893248708,-1.1790857661474947,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-395MB,PT IDN SOLAR TECH,Mono-c-Si,0,395.0,368.7,2.01,,,72.0,10.19,49.2,9.62,41.1,0.00462626,-0.1570956,43.1,1.9109351229196812,10.195881545390199,6.631346076782714e-11,0.23243490950701315,402.7022893248708,-1.1790857661474947,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108-400MB,PT IDN SOLAR TECH,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-400M,PT IDN SOLAR TECH,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-400MB,PT IDN SOLAR TECH,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-400MT,PT IDN SOLAR TECH,Mono-c-Si,0,400.0,376.7,1.95,,,54.0,13.79,37.04,12.9,31.01,0.005543579999999999,-0.10586032000000001,43.1,1.364541967801907,13.808369659213367,2.187016543079894e-11,0.13646720402456702,102.44516400973474,-1.314245895470512,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-400M,PT IDN SOLAR TECH,Mono-c-Si,0,400.0,373.5,2.01,,,72.0,10.26,49.5,9.69,41.3,0.0046580400000000004,-0.15805349999999999,43.1,1.920910209950488,10.265771498515031,6.532394436128496e-11,0.23837572976413618,423.7608381010788,-1.3550728707284696,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-400MB,PT IDN SOLAR TECH,Mono-c-Si,0,400.0,373.5,2.01,,,72.0,10.26,49.5,9.69,41.3,0.0046580400000000004,-0.15805349999999999,43.1,1.920910209950488,10.265771498515031,6.532394436128496e-11,0.23837572976413618,423.7608381010788,-1.3550728707284696,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108-405MB,PT IDN SOLAR TECH,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-405M,PT IDN SOLAR TECH,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-405MB,PT IDN SOLAR TECH,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-405MT,PT IDN SOLAR TECH,Mono-c-Si,0,405.0,381.5,1.95,,,54.0,13.87,37.23,12.98,31.21,0.005575739999999999,-0.10640333999999999,43.1,1.372200256938768,13.887720476689063,2.229328281792526e-11,0.13278372146958922,103.93118968306636,-1.2083089735730577,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-405M,PT IDN SOLAR TECH,Mono-c-Si,0,405.0,378.3,2.01,,,72.0,10.32,49.8,9.75,41.5,0.00468528,-0.1590114,43.1,1.9309442286930714,10.325675380487684,6.43446938787769e-11,0.2444586606022622,444.51882293816027,-1.5230177330428074,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-405MB,PT IDN SOLAR TECH,Mono-c-Si,0,405.0,378.3,2.01,,,72.0,10.32,49.8,9.75,41.5,0.00468528,-0.1590114,43.1,1.9309442286930714,10.325675380487684,6.43446938787769e-11,0.2444586606022622,444.51882293816027,-1.5230177330428074,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108-410MB,PT IDN SOLAR TECH,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-410M,PT IDN SOLAR TECH,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-410MB,PT IDN SOLAR TECH,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-410MT,PT IDN SOLAR TECH,Mono-c-Si,0,410.0,386.3,1.95,,,54.0,13.95,37.32,13.04,31.45,0.005607899999999999,-0.10666056000000002,43.1,1.3800555088956825,13.966907481322902,2.4469595714697477e-11,0.11774413971850448,97.14816318204721,-0.4998022678087733,-0.3368,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA144H-410M,PT IDN SOLAR TECH,Mono-c-Si,0,410.0,383.1,2.01,,,72.0,10.38,50.1,9.82,41.8,0.00471252,-0.15996929999999998,43.1,1.9424779133129813,10.384775999033259,6.473000916921305e-11,0.23882398099125005,519.0522426396667,-1.526361267737516,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-410MB,PT IDN SOLAR TECH,Mono-c-Si,0,410.0,383.1,2.01,,,72.0,10.38,50.1,9.82,41.8,0.00471252,-0.15996929999999998,43.1,1.9424779133129813,10.384775999033259,6.473000916921305e-11,0.23882398099125005,519.0522426396667,-1.526361267737516,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA108H-415M,PT IDN SOLAR TECH,Mono-c-Si,0,415.0,389.4,1.95,,,54.0,14.02,37.45,13.13,31.61,0.00758482,-0.10186400000000002,43.6,1.4268018200180161,14.0333563973722,5.463672240262274e-11,0.10616428128059485,111.43897514456997,11.34958194532629,-0.3526,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA108H-415MB,PT IDN SOLAR TECH,Mono-c-Si,0,415.0,389.4,1.95,,,54.0,14.02,37.45,13.13,31.61,0.00758482,-0.10186400000000002,43.6,1.4268018200180161,14.0333563973722,5.463672240262274e-11,0.10616428128059485,111.43897514456997,11.34958194532629,-0.3526,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA108H-415MT,PT IDN SOLAR TECH,Mono-c-Si,0,415.0,391.2,1.95,,,54.0,14.02,37.45,13.13,31.61,0.005636039999999999,-0.10703210000000002,43.1,1.384695861702404,14.035108480855449,2.456286701786383e-11,0.11334312919759114,105.17739619951388,-0.5164877704353091,-0.3368,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH IDN108H-420ND,PT IDN SOLAR TECH,Mono-c-Si,0,420.0,395.6,2.8,,,54.0,13.74,39.04,12.96,32.43,0.00567462,-0.09361792000000001,43.5,1.353789821621375,13.75576578237502,4.041745648020905e-12,0.18018079454526942,157.02894155069146,2.5576162334279933,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN108H-425ND,PT IDN SOLAR TECH,Mono-c-Si,0,425.0,400.4,2.8,,,54.0,13.81,39.24,13.03,32.63,0.00570353,-0.09409752000000002,43.5,1.3612089881469789,13.825334137320066,4.105252166738172e-12,0.1772317589146221,159.61578884544784,2.6455379202608573,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-425M,PT IDN SOLAR TECH,Mono-c-Si,0,425.0,396.7,2.18,,,72.0,11.03,49.3,10.48,40.6,0.00743422,-0.13877949999999997,43.2,1.9131439527302476,11.031439843422156,7.084955696102789e-11,0.27669412368002905,2119.6311822532284,11.748970303621768,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN108H-430ND,PT IDN SOLAR TECH,Mono-c-Si,0,430.0,405.1,2.8,,,54.0,13.88,39.44,13.1,32.83,0.005732440000000001,-0.09457712,43.5,1.368627300247547,13.894911261469092,4.1691014456540546e-12,0.17431488063999653,162.25927982612149,2.732416533284615,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-430M,PT IDN SOLAR TECH,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.00747466,-0.13934249999999998,43.2,1.9206247755298367,11.090446120627426,7.106412910243101e-11,0.27252668724174006,6774.6762115524325,11.72253832985782,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-430MB,PT IDN SOLAR TECH,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.00747466,-0.13934249999999998,43.2,1.9206247755298367,11.090446120627426,7.106412910243101e-11,0.27252668724174006,6774.6762115524325,11.72253832985782,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN108H-435ND,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,409.9,2.8,,,54.0,13.95,39.64,13.17,33.03,0.00576135,-0.09505672000000001,43.5,1.3760474059547272,13.964499357236539,4.233511925535839e-12,0.1714292195459794,164.93404333460128,2.8187260428368277,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-435M,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,40.95,12.96,33.63,0.007395470000000001,-0.11138400000000001,43.6,1.5290244116054013,13.676148139014527,3.1761523952668715e-11,0.20361617907753368,452.7278143631316,6.721421091413095,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-435MB,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,40.95,12.96,33.63,0.007395470000000001,-0.11138400000000001,43.6,1.5290244116054013,13.676148139014527,3.1761523952668715e-11,0.20361617907753368,452.7278143631316,6.721421091413095,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-435MT,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,409.5,2.16,,,60.0,13.67,40.95,12.96,33.63,0.0054953400000000005,-0.1170351,43.1,1.4841122185016034,13.677885794932749,1.4102290906856491e-11,0.21119968211914672,366.113967774613,-4.758869008897125,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-435M,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.00752184,-0.1399055,43.2,1.929833287779945,11.16102799124803,7.28496486134871e-11,0.26802474555028777,2909.710412982423,11.893019428052531,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-435MB,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.00752184,-0.1399055,43.2,1.929833287779945,11.16102799124803,7.28496486134871e-11,0.26802474555028777,2909.710412982423,11.893019428052531,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-435MD,PT IDN SOLAR TECH,Mono-c-Si,0,435.0,406.9,2.18,,,72.0,11.36,49.1,10.66,40.8,0.00570272,-0.13860930000000002,43.4,1.8729471560590472,11.37241967435911,4.591494739626983e-11,0.2377550568684336,217.46926692082187,7.606568167228922,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN108H-440ND,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,414.7,2.8,,,54.0,14.02,39.84,13.24,33.24,0.00579026,-0.09553632000000001,43.5,1.3836588905545288,14.034038652213411,4.3153954549500335e-12,0.1677156860095924,167.49285368804485,2.937860915488559,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-440M,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.02,13.05,33.72,0.007427930000000001,-0.11157440000000003,43.6,1.5305495397668754,13.733250837708983,3.138945279212656e-11,0.20025165287596605,845.7682522336652,6.571426706940132,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-440MB,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.02,13.05,33.72,0.007427930000000001,-0.11157440000000003,43.6,1.5305495397668754,13.733250837708983,3.138945279212656e-11,0.20025165287596605,845.7682522336652,6.571426706940132,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-440MT,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,414.3,2.16,,,60.0,13.73,41.02,13.05,33.72,0.00551946,-0.11723516000000002,43.1,1.485601328724064,13.734869557549908,1.3931237777183332e-11,0.20779016289208946,585.8764285856134,-4.896913676965568,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-440M,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.007569020000000001,-0.1404685,43.2,1.866710648235963,11.230112914142936,2.7603601167722432e-11,0.2780775949614765,27656.541633959812,3.369717118948399,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-440MB,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.007569020000000001,-0.1404685,43.2,1.866710648235963,11.230112914142936,2.7603601167722432e-11,0.2780775949614765,27656.541633959812,3.369717118948399,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-440MD,PT IDN SOLAR TECH,Mono-c-Si,0,440.0,411.7,2.18,,,72.0,11.45,49.2,10.73,41.0,0.005747899999999999,-0.1388916,43.4,1.8510022791233687,11.450006415072911,3.274684855417225e-11,0.2292833616762263,409244.9884489561,4.573426523333611,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN108H-445ND,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,419.5,2.8,,,54.0,14.09,40.04,13.31,33.45,0.00581917,-0.09601592,43.5,1.3912717834491586,14.10359009414394,4.398191799948548e-12,0.1640417452798672,170.07595187213198,3.0560436548912566,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-445M,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,417.2,2.16,,,60.0,13.79,41.1,13.16,33.82,0.00746039,-0.11179200000000002,43.6,1.5230357694994607,13.790005128939356,2.629508271735187e-11,0.19826140688761676,533072.2356760007,5.002385774862916,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-445MB,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,417.2,2.16,,,60.0,13.79,41.1,13.16,33.82,0.00746039,-0.11179200000000002,43.6,1.5230357694994607,13.790005128939356,2.629508271735187e-11,0.19826140688761676,533072.2356760007,5.002385774862916,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-445MT,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,419.1,2.16,,,60.0,13.79,41.1,13.16,33.82,0.005543579999999999,-0.11746380000000001,43.1,1.4864582587542075,13.790142601502065,1.3534044699295004e-11,0.20433139560601304,19759.433903306184,-5.169693213362219,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-445M,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,415.9,2.18,,,72.0,11.29,50.1,10.75,41.4,0.00760946,-0.14103149999999998,43.2,1.9457737635764378,11.291804332043654,7.421618610378759e-11,0.25959776787723093,999999.9472949086,11.950145616635265,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA144H-445MB,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,415.9,2.18,,,72.0,11.29,50.1,10.75,41.4,0.00760946,-0.14103149999999998,43.2,1.9457737635764378,11.291804332043654,7.421618610378759e-11,0.25959776787723093,999999.9472949086,11.950145616635265,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA144H-445MD,PT IDN SOLAR TECH,Mono-c-Si,0,445.0,417.1,2.06,,,72.0,11.29,50.1,10.75,41.4,0.00566758,-0.1414323,43.4,1.8919347495722665,11.290902207305733,3.561895034945718e-11,0.2704612371320979,3384.4857043142447,5.4113027916666026,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-450M,PT IDN SOLAR TECH,Mono-c-Si,0,450.0,422.0,2.16,,,60.0,13.85,41.18,13.27,33.91,0.0074928500000000006,-0.11200960000000001,43.6,1.5301606964755194,13.850005010708049,2.842005641451503e-11,0.1947939459496308,538440.8843964805,5.629540063448199,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-450MB,PT IDN SOLAR TECH,Mono-c-Si,0,450.0,422.0,2.16,,,60.0,13.85,41.18,13.27,33.91,0.0074928500000000006,-0.11200960000000001,43.6,1.5301606964755194,13.850005010708049,2.842005641451503e-11,0.1947939459496308,538440.8843964805,5.629540063448199,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-450MT,PT IDN SOLAR TECH,Mono-c-Si,0,450.0,423.9,2.16,,,60.0,13.85,41.18,13.27,33.91,0.0055677,-0.11769244,43.1,1.4920666475723516,13.850005205327836,1.4296258116190338e-11,0.20104708237878274,534941.114687128,-4.780291992713238,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-450M,PT IDN SOLAR TECH,Mono-c-Si,0,450.0,420.7,2.18,,,72.0,11.36,50.3,10.82,41.6,0.007656639999999999,-0.14159449999999998,43.2,1.9542971750206481,11.36449522382689,7.544150416986332e-11,0.255261749955157,999999.9476024729,12.04060921559822,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA144H-450MB,PT IDN SOLAR TECH,Mono-c-Si,0,450.0,420.7,2.18,,,72.0,11.6,50.3,10.82,41.6,0.0078184,-0.14159449999999998,43.2,1.9744165620762837,11.616850989690418,9.769958850362228e-11,0.24790171732329377,170.65228978513952,14.303507225865076,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-450MD,PT IDN SOLAR TECH,Mono-c-Si,0,450.0,421.9,2.06,,,72.0,11.36,50.3,10.82,41.6,0.00570272,-0.1419969,43.4,1.9000226647394944,11.36069197158671,3.611825167331889e-11,0.2661852605820229,4369.927701136578,5.476315267124399,-0.3635,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-455M,PT IDN SOLAR TECH,Mono-c-Si,0,455.0,426.8,2.16,,,60.0,13.93,41.33,13.36,34.06,0.007536130000000001,-0.1124176,43.6,1.5413926366914639,14.013466063613366,3.1741411496157716e-11,0.19047938999153652,999999.8801695533,6.4836709139633335,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-455MB,PT IDN SOLAR TECH,Mono-c-Si,0,455.0,426.8,2.16,,,60.0,13.93,41.33,13.36,34.06,0.007536130000000001,-0.1124176,43.6,1.5413926366914639,14.013466063613366,3.1741411496157716e-11,0.19047938999153652,999999.8801695533,6.4836709139633335,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-455MT,PT IDN SOLAR TECH,Mono-c-Si,0,455.0,428.8,2.16,,,60.0,13.93,41.33,13.36,34.06,0.00559986,-0.11812114,43.1,1.4987166881123117,13.930100641173183,1.470280684686477e-11,0.19815960873086885,27427.795936328566,-4.607318671140062,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-455MB,PT IDN SOLAR TECH,Mono-c-Si,0,455.0,425.5,2.18,,,72.0,11.41,50.4,10.88,41.82,0.00769034,-0.14187599999999997,43.2,1.9330730067788242,11.41000478856104,5.4218812071659794e-11,0.24567650703205993,585410.2116740027,9.047916932303378,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-460M,PT IDN SOLAR TECH,Mono-c-Si,0,460.0,431.6,2.16,,,60.0,14.01,41.48,13.45,34.2,0.007579410000000001,-0.11282560000000001,43.6,1.5524721762199485,14.010002376709336,3.4887003869949945e-11,0.16963465526314545,999999.4221514936,7.30043531295308,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-460MB,PT IDN SOLAR TECH,Mono-c-Si,0,460.0,431.6,2.16,,,60.0,14.01,41.48,13.45,34.2,0.007579410000000001,-0.11282560000000001,43.6,1.5524721762199485,14.010002376709336,3.4887003869949945e-11,0.16963465526314545,999999.4221514936,7.30043531295308,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA120H-460MT,PT IDN SOLAR TECH,Mono-c-Si,0,460.0,433.6,2.16,,,60.0,14.01,41.48,13.45,34.2,0.00563202,-0.11854984,43.1,1.5049606482918279,14.010005147474768,1.5008321711420055e-11,0.19619110176150273,533985.9299124029,-4.49250483162325,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-465ND,PT IDN SOLAR TECH,Mono-c-Si,0,465.0,440.9,2.16,,,60.0,13.71,43.3,12.91,36.02,0.005662230000000001,-0.1038334,43.5,1.5036743224021554,13.727212211803582,4.194736101712233e-12,0.1957129664635511,155.89075969278824,2.8989237733251,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-470ND,PT IDN SOLAR TECH,Mono-c-Si,0,470.0,445.8,2.16,,,60.0,13.78,43.5,12.98,36.22,0.005691140000000001,-0.104313,43.5,1.5110719374995887,13.79677498370141,4.2538463164662026e-12,0.1926762327027735,158.27606972755405,2.973365363117552,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-475ND,PT IDN SOLAR TECH,Mono-c-Si,0,475.0,450.6,2.16,,,60.0,13.85,43.7,13.05,36.42,0.005720050000000001,-0.10479260000000001,43.5,1.518468961659592,13.866346070311783,4.313255803596818e-12,0.18967259852140494,160.70929870358714,3.047026655950045,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-480ND,PT IDN SOLAR TECH,Mono-c-Si,0,480.0,455.5,2.16,,,60.0,13.92,43.9,13.12,36.62,0.00574896,-0.10527220000000001,43.5,1.5258653946142766,13.935925326518404,4.372961403148268e-12,0.18670152512548252,163.19195898004088,3.1199220320852343,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA132H-480MT,PT IDN SOLAR TECH,Mono-c-Si,0,480.0,451.9,2.37,,,66.0,13.59,44.95,12.71,37.78,0.00546318,-0.1284671,43.1,1.6594999080837014,13.607001683643835,2.282938301714373e-11,0.15466690416228884,123.63029924140879,-0.8507208463552234,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-485ND,PT IDN SOLAR TECH,Mono-c-Si,0,485.0,460.3,2.16,,,60.0,13.99,44.1,13.19,36.82,0.00577787,-0.1057518,43.5,1.5332612681546025,14.00551263152814,4.432962449439887e-12,0.18376248224230227,165.72540355582805,3.192065631571743,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA132H-485MT,PT IDN SOLAR TECH,Mono-c-Si,0,485.0,456.7,2.37,,,66.0,13.67,45.1,12.79,37.93,0.0054953400000000005,-0.1288958,43.1,1.6652422978391077,13.686587664050533,2.3049960231742513e-11,0.15217224894686332,125.40614667739527,-0.8220264708395452,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-490ND,PT IDN SOLAR TECH,Mono-c-Si,0,490.0,465.2,2.16,,,60.0,14.06,44.3,13.26,37.02,0.005806780000000001,-0.1062314,43.5,1.5406565704309734,14.075107836012293,4.493254899042518e-12,0.18085495731844548,168.3113783082671,3.263465929531179,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA132H-490MT,PT IDN SOLAR TECH,Mono-c-Si,0,490.0,461.5,2.37,,,66.0,13.74,45.25,12.87,38.08,0.00552348,-0.1293245,43.1,1.6703731686036671,13.755631389444616,2.304461595720711e-11,0.14990380275407292,131.7655264200916,-0.8692458634046452,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN120H-495ND,PT IDN SOLAR TECH,Mono-c-Si,0,495.0,470.0,2.16,,,60.0,14.13,44.5,13.32,37.22,0.005835690000000001,-0.10671100000000001,43.5,1.548581374989318,14.145436272639774,4.594834346657736e-12,0.17794181704400827,162.88374376111432,3.413872293166291,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA132H-495MT,PT IDN SOLAR TECH,Mono-c-Si,0,495.0,466.4,2.37,,,66.0,13.82,45.4,12.95,38.23,0.005555640000000001,-0.1297532,43.1,1.6761193111450883,13.835239665187416,2.326659947229575e-11,0.14746856246670545,133.730991936408,-0.8402322851938739,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA132H-500MT,PT IDN SOLAR TECH,Mono-c-Si,0,500.0,471.2,2.37,,,66.0,13.9,45.55,13.03,38.38,0.0055878,-0.1301819,43.1,1.6818666390864299,13.914854856944697,2.3489722697452703e-11,0.14506302302442914,135.7385018885876,-0.8112684590265496,-0.3368,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA132H-505MT,PT IDN SOLAR TECH,Mono-c-Si,0,505.0,476.0,2.37,,,66.0,13.98,45.69,13.11,38.53,0.00561996,-0.13058202,43.1,1.6874365958006494,13.994410889768979,2.378620906802953e-11,0.1419171897496132,137.67382536637044,-0.7578321291504029,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN132H-515ND,PT IDN SOLAR TECH,Mono-c-Si,0,515.0,488.4,2.37,,,66.0,13.78,47.39,13.04,39.55,0.005691140000000001,-0.11364122,43.5,1.6445642748017362,13.791733465888717,4.1552211001737976e-12,0.20211882148835422,237.37209374199927,2.7543694177340976,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN132H-520ND,PT IDN SOLAR TECH,Mono-c-Si,0,520.0,493.3,2.37,,,66.0,13.84,47.58,13.1,39.74,0.00571592,-0.11409684,43.5,1.6515924593980051,13.85143554702671,4.20598674236021e-12,0.199329252569805,241.24047379829767,2.8196160597302997,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN132H-525ND,PT IDN SOLAR TECH,Mono-c-Si,0,525.0,498.1,2.37,,,66.0,13.9,47.78,13.16,39.94,0.005740700000000001,-0.11457644,43.5,1.658999799241364,13.911137676066682,4.259356468413398e-12,0.19646477282389183,245.19121664940434,2.889029195626565,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN132H-530ND,PT IDN SOLAR TECH,Mono-c-Si,0,530.0,503.0,2.37,,,66.0,13.96,47.98,13.22,40.14,0.005765480000000001,-0.11505604000000001,43.5,1.6664064551319608,13.970845227791115,4.312955704638634e-12,0.19362677410775794,249.23679090634337,2.9577643545321743,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-530MT,PT IDN SOLAR TECH,Mono-c-Si,0,530.0,499.1,2.58,,,72.0,13.71,49.2,12.82,41.35,0.0055114199999999995,-0.1406136,43.1,1.8165167505321953,13.72730070817944,2.3064832157688962e-11,0.16797343412399982,133.11106855803726,-0.8382355067563787,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN132H-535ND,PT IDN SOLAR TECH,Mono-c-Si,0,535.0,507.8,2.37,,,66.0,14.02,48.18,13.28,40.34,0.00579026,-0.11553564000000001,43.5,1.6738124997045318,14.030558171322065,4.36678700554185e-12,0.1908148804626692,253.37954333104125,3.025839972858641,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-535MD,PT IDN SOLAR TECH,Mono-c-Si,0,535.0,504.0,2.57,,,72.0,13.78,49.35,12.9,41.5,0.00500214,-0.13669950000000003,43.2,1.807552380510051,13.796819228054702,1.8672056475802498e-11,0.16808111709335782,137.7089242373536,0.6012352993183838,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-535MT,PT IDN SOLAR TECH,Mono-c-Si,0,535.0,504.0,2.58,,,72.0,13.78,49.35,12.9,41.5,0.00553956,-0.1410423,43.1,1.821563613337586,13.796342089761378,2.3043214387899365e-11,0.16563878608039367,139.67017153599164,-0.8910064142872832,-0.3368,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH IDN132H-540ND,PT IDN SOLAR TECH,Mono-c-Si,0,540.0,512.7,2.37,,,66.0,14.08,48.38,13.34,40.54,0.0058150400000000005,-0.11601524000000002,43.5,1.6812179596888215,14.090276440507251,4.420849816257172e-12,0.188028729534979,257.62271441514827,3.093268513989369,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-540MD,PT IDN SOLAR TECH,Mono-c-Si,0,540.0,508.8,2.57,,,72.0,13.85,49.5,12.97,41.65,0.00502755,-0.13711500000000001,43.2,1.8132661183789467,13.866454243113246,1.8835726824329694e-11,0.16567111667133436,139.45004682289462,0.6298632449013583,-0.3353,N,2025.7.3,6/23/2025,2.0,first_pass +PT IDN SOLAR TECH NUSA144H-540MT,PT IDN SOLAR TECH,Mono-c-Si,0,540.0,508.8,2.58,,,72.0,13.85,49.5,12.97,41.65,0.0055677,-0.14147099999999999,43.1,1.8273250647847314,13.865981283558552,2.324578964310899e-11,0.1632328928503046,141.46395485243974,-0.8625914235781719,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-545MD,PT IDN SOLAR TECH,Mono-c-Si,0,545.0,513.6,2.57,,,72.0,13.92,49.65,13.04,41.8,0.00505296,-0.1375305,43.2,1.8189806959533932,13.936094916667075,1.9000118668155362e-11,0.1632868812527612,141.22181798244748,0.6584113642523622,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-545MT,PT IDN SOLAR TECH,Mono-c-Si,0,545.0,513.6,2.58,,,72.0,13.92,49.65,13.04,41.8,0.0055958399999999995,-0.1418997,43.1,1.8330873743521034,13.935626142449404,2.344926331398915e-11,0.1608527169063229,143.2899921593584,-0.8342547567182711,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-550MD,PT IDN SOLAR TECH,Mono-c-Si,0,550.0,518.5,2.57,,,72.0,13.99,49.8,13.11,41.95,0.00507837,-0.137946,43.2,1.8246961440467402,14.00574119889923,1.9165241597205742e-11,0.16092799286718248,143.02485054801647,0.6868853510655905,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-550MT,PT IDN SOLAR TECH,Mono-c-Si,0,550.0,518.4,2.58,,,72.0,13.99,49.8,13.11,41.95,0.00562398,-0.1423284,43.1,1.8388505292419084,14.005276595451738,2.3653632585623918e-11,0.15849784888134613,145.14915463236258,-0.8059974901319501,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-555MD,PT IDN SOLAR TECH,Mono-c-Si,0,555.0,523.3,2.57,,,72.0,14.02,49.95,13.18,42.09,0.00508926,-0.13836150000000003,43.2,1.8276061971576338,14.033297479756067,1.854744956353901e-11,0.1602745922036483,168.98313319433055,0.3889870935193644,-0.3353,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH NUSA144H-555MT,PT IDN SOLAR TECH,Mono-c-Si,0,555.0,523.3,2.58,,,72.0,14.02,49.95,13.18,42.09,0.005636039999999999,-0.14275710000000003,43.1,1.8417537947107199,14.032870391893294,2.2888117476446714e-11,0.1578597079971288,171.96004051326483,-1.1000082370574973,-0.3368,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-560ND,PT IDN SOLAR TECH,Mono-c-Si,0,560.0,531.1,2.58,,,72.0,13.75,51.7,13.0,43.09,0.005678750000000001,-0.1239766,43.5,1.7937336078389807,13.762784894168096,4.115851268501567e-12,0.22592999948558978,242.98500043122021,2.6957804519351654,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-565ND,PT IDN SOLAR TECH,Mono-c-Si,0,565.0,535.9,2.58,,,72.0,13.81,51.9,13.06,43.28,0.00570353,-0.12445620000000002,43.5,1.8009283619041923,13.822508930970049,4.15177511924303e-12,0.22379720132434278,247.07461911561998,2.7315606787715105,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-570ND,PT IDN SOLAR TECH,Mono-c-Si,0,570.0,540.8,2.58,,,72.0,13.87,52.1,13.12,43.66,0.00572831,-0.12493580000000001,43.5,1.81185975284468,13.881587703417246,4.442429602741242e-12,0.20520776097188498,245.62517237404327,3.269788251283698,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-575ND,PT IDN SOLAR TECH,Mono-c-Si,0,575.0,545.6,2.58,,,72.0,13.93,52.3,13.18,43.85,0.005753090000000001,-0.1254154,43.5,1.8190516203441855,13.941333232879646,4.4794427300016285e-12,0.2031908983755248,249.7477326476447,3.302713016308857,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-580ND,PT IDN SOLAR TECH,Mono-c-Si,0,580.0,550.5,2.58,,,72.0,13.99,52.5,13.24,43.85,0.00577787,-0.125895,43.5,1.8225117600603968,14.001705165658338,4.260020664598553e-12,0.21751587568588845,259.9747149643924,2.837132644727165,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-585ND,PT IDN SOLAR TECH,Mono-c-Si,0,585.0,555.4,2.58,,,72.0,14.05,52.7,13.3,44.04,0.005802650000000001,-0.1263746,43.5,1.8194176555264163,14.051857784226636,3.681954357112178e-12,0.21701343262857567,1613.0070416877352,1.5491506171560774,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-590ND,PT IDN SOLAR TECH,Mono-c-Si,0,590.0,560.2,2.58,,,72.0,14.11,52.9,13.36,44.23,0.005827430000000001,-0.1268542,43.5,1.8368999883072525,14.121188873869505,4.332572730867236e-12,0.21342322654214813,269.14252197783327,2.9060820358680926,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN144H-595ND,PT IDN SOLAR TECH,Mono-c-Si,0,595.0,565.1,2.58,,,72.0,14.17,53.1,13.42,44.42,0.00585221,-0.12733380000000002,43.5,1.8440938974250258,14.180936433895903,4.368963394936901e-12,0.211404601277456,273.9104203013978,2.9401379263291063,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-610ND,PT IDN SOLAR TECH,Mono-c-Si,0,610.0,578.6,2.8,,,78.0,13.81,56.5,13.06,46.72,0.00570353,-0.13548700000000002,43.5,1.9527332036664047,13.823631160640385,3.702421643463113e-12,0.2781638895278959,281.81337014540395,1.7621364509783222,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-615ND,PT IDN SOLAR TECH,Mono-c-Si,0,615.0,583.4,2.8,,,78.0,13.87,56.7,13.12,46.91,0.00572831,-0.13596660000000002,43.5,1.959915331752317,13.883339541261801,3.734245230704611e-12,0.27580415543019215,286.7717538244901,1.7967038786682359,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-620ND,PT IDN SOLAR TECH,Mono-c-Si,0,620.0,588.3,2.8,,,78.0,13.93,56.9,13.18,47.1,0.005753090000000001,-0.1364462,43.5,1.96709743820762,13.943051856079318,3.766153128150925e-12,0.27346605664176243,291.86516868088194,1.8310228622600981,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-625ND,PT IDN SOLAR TECH,Mono-c-Si,0,625.0,593.1,2.8,,,78.0,13.99,57.1,13.24,47.29,0.00577787,-0.13692580000000001,43.5,1.9742795293902522,14.002768057621953,3.798145118026405e-12,0.27114929582781333,297.09911762988315,1.8650973412117353,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-630ND,PT IDN SOLAR TECH,Mono-c-Si,0,630.0,598.0,2.8,,,78.0,14.04,57.3,13.29,47.48,0.005798520000000001,-0.13740539999999998,43.5,1.981497074322262,14.052525029536172,3.829296813862589e-12,0.2690445076147894,301.5869050579882,1.9030712138771766,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-635ND,PT IDN SOLAR TECH,Mono-c-Si,0,635.0,602.8,2.8,,,78.0,14.1,57.5,13.34,47.67,0.0058233,-0.13788500000000004,43.5,1.98934401884911,14.113099726996019,3.8955420930137684e-12,0.26675454863197834,287.12347540645726,2.0140130829360774,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-640ND,PT IDN SOLAR TECH,Mono-c-Si,0,640.0,607.7,2.8,,,78.0,14.15,57.7,13.39,47.86,0.005843950000000001,-0.13836460000000003,43.5,1.9965612024766115,14.162856042985394,3.926979094931053e-12,0.2646822370340014,291.3224283233453,2.051165579538274,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT IDN SOLAR TECH IDN156H-645ND,PT IDN SOLAR TECH,Mono-c-Si,0,645.0,612.5,2.8,,,78.0,14.2,57.9,13.44,48.05,0.0058646,-0.1388442,43.5,2.003778068076985,14.212615430600605,3.958474252912837e-12,0.26262557259265823,295.6128296642752,2.088021849047794,-0.2985,N,2025.7.3,6/23/2025,4.0,first_pass +PT LESSO NEW ENERGY 410D(BPM)54(182),PT LESSO NEW ENERGY,Mono-c-Si,0,410.0,384.4,1.96,,,54.0,13.75,37.3,13.05,31.42,0.0053625,-0.092131,45.55,1.3223030568617808,13.757116373543917,7.639764365409579e-12,0.13002233648942857,251.22446442645924,4.893033192304889,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +PT LESSO NEW ENERGY 430C(HBB)54(182),PT LESSO NEW ENERGY,Mono-c-Si,0,430.0,406.2,1.95,,,54.0,14.82,40.13,13.57,31.69,0.00693576,-0.09326212,46.36,1.3490173515841648,14.91065299906066,1.7019201061517044e-12,0.3145284016708151,51.419268681086194,-2.081441785440063,-0.2781,N,2025.7.3,6/23/2025,2.0,first_pass +PT LESSO NEW ENERGY 435C(HWB)54(182),PT LESSO NEW ENERGY,Mono-c-Si,0,435.0,412.2,1.96,,,54.0,14.79,39.17,13.55,32.11,0.0063449100000000005,-0.09929595000000001,44.4,1.3621470135701206,14.850511098117058,4.566224369446293e-12,0.20420024791115043,49.910210894305436,-2.5378407662885385,-0.2912,N,2025.7.3,6/23/2025,2.0,first_pass +PT LESSO NEW ENERGY 480C(HWB)60(182),PT LESSO NEW ENERGY,Mono-c-Si,0,480.0,454.0,2.16,,,60.0,14.61,43.52,13.53,35.48,0.00580017,-0.10688512000000001,44.7,1.5048654035885909,14.65757588477615,3.881799519215096e-12,0.2456801333156196,75.44550705668108,-0.6206599233823525,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +PT LESSO NEW ENERGY 550D(HBD)72(182),PT LESSO NEW ENERGY,Mono-c-Si,0,550.0,516.0,2.58,,,72.0,14.01,49.78,13.12,41.93,0.0056040000000000005,-0.1239522,45.56,1.7879203596947908,14.027546006998648,1.1052855371352204e-11,0.16713387028455773,133.45176066862854,7.113911015105111,-0.319,N,2025.7.3,6/23/2025,2.0,first_pass +PT LESSO NEW ENERGY 580C(HBD)72(182),PT LESSO NEW ENERGY,Mono-c-Si,0,580.0,546.6,2.58,,,72.0,14.33,52.42,13.57,42.75,0.00680675,-0.12360636,46.53,1.791068492502668,14.343895258877168,2.759422463848083e-12,0.300103223874556,309.49255748258093,0.601201513900876,-0.2898,N,2025.7.3,6/23/2025,4.0,first_pass +PT LESSO NEW ENERGY 580C(HWB)72(182),PT LESSO NEW ENERGY,Mono-c-Si,0,580.0,548.4,2.58,,,72.0,14.33,52.42,13.57,42.75,0.00634819,-0.12952982,44.9,1.803821776492889,14.343381446774318,3.394888924713309e-12,0.2980046363910848,319.1289032821855,-2.321583254951687,-0.2968,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-550-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,550.0,522.4,2.58,,,72.0,12.68,52.45,12.06,45.6,0.0052840096,-0.13500105500000004,43.2,1.845357777507411,12.6825808329415,5.6798846642300815e-12,0.07269261811527303,357.14919211810593,-1.1564282571569693,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-550-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,550.0,522.4,2.58,,,72.0,12.68,52.45,12.06,45.6,0.0052840096,-0.13500105500000004,43.2,1.845357777507411,12.6825808329415,5.6798846642300815e-12,0.07269261811527303,357.14919211810593,-1.1564282571569693,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-555-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,555.0,527.3,2.58,,,72.0,12.76,52.59,12.13,45.75,0.0053173472,-0.13536140100000002,43.2,1.8512775971373658,12.7626336284211,5.7999605829102104e-12,0.06966930353320115,337.5496360904558,-1.0352919871870039,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-555-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,555.0,527.3,2.58,,,72.0,12.76,52.59,12.13,45.75,0.0053173472,-0.13536140100000002,43.2,1.8512775971373658,12.7626336284211,5.7999605829102104e-12,0.06966930353320115,337.5496360904558,-1.0352919871870039,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-560-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,560.0,532.1,2.58,,,72.0,12.84,52.73,12.2,45.9,0.005350684800000001,-0.135721747,43.2,1.857195932724269,12.842674788416266,5.921674744347107e-12,0.0666812699365193,320.0954148697964,-0.9149718624922734,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-560-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,560.0,532.1,2.58,,,72.0,12.84,52.73,12.2,45.9,0.005350684800000001,-0.135721747,43.2,1.857195932724269,12.842674788416266,5.921674744347107e-12,0.0666812699365193,320.0954148697964,-0.9149718624922734,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-565-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,565.0,537.0,2.58,,,72.0,12.92,52.87,12.27,46.04,0.005384022400000001,-0.136082093,43.2,1.86291858350712,12.922740686115379,6.027280173594249e-12,0.06465011039806091,304.77018994468864,-0.8194525843794598,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-565-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,565.0,537.0,2.58,,,72.0,12.92,52.87,12.27,46.04,0.005384022400000001,-0.136082093,43.2,1.86291858350712,12.922740686115379,6.027280173594249e-12,0.06465011039806091,304.77018994468864,-0.8194525843794598,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-570-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,570.0,541.9,2.58,,,72.0,13.0,53.01,12.34,46.19,0.00541736,-0.136442439,43.2,1.8688338881627524,13.002760935089618,6.1519831426760116e-12,0.06172559402541871,290.6380257877678,-0.7006902901522712,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-570-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,570.0,541.9,2.58,,,72.0,13.0,53.01,12.34,46.19,0.00541736,-0.136442439,43.2,1.8688338881627524,13.002760935089618,6.1519831426760116e-12,0.06172559402541871,290.6380257877678,-0.7006902901522712,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-575-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,575.0,546.7,2.58,,,72.0,13.08,53.15,12.41,46.33,0.0054506976,-0.136802785,43.2,1.8745532839839982,13.082810144405641,6.2600114739051196e-12,0.05974646257801248,278.0937984049008,-0.606617888163782,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-575-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,575.0,546.7,2.58,,,72.0,13.08,53.15,12.41,46.33,0.0054506976,-0.136802785,43.2,1.8745532839839982,13.082810144405641,6.2600114739051196e-12,0.05974646257801248,278.0937984049008,-0.606617888163782,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-580-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,580.0,551.6,2.58,,,72.0,13.16,53.29,12.48,46.47,0.0054840352,-0.13716313100000002,43.2,1.8802710177290844,13.162852094394314,6.3691216439864236e-12,0.057790112823033445,266.65242478020934,-0.5132333527516126,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-580-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,580.0,551.6,2.58,,,72.0,13.16,53.29,12.48,46.47,0.0054840352,-0.13716313100000002,43.2,1.8802710177290844,13.162852094394314,6.3691216439864236e-12,0.057790112823033445,266.65242478020934,-0.5132333527516126,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-585-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,585.0,556.4,2.58,,,72.0,13.24,53.43,12.55,46.6,0.005517372800000001,-0.137523477,43.2,1.885792330490881,13.242930999080158,6.460490931867769e-12,0.05675790254724142,256.38855907925443,-0.44433922535291914,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-585-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,585.0,556.4,2.58,,,72.0,13.24,53.43,12.55,46.6,0.005517372800000001,-0.137523477,43.2,1.885792330490881,13.242930999080158,6.460490931867769e-12,0.05675790254724142,256.38855907925443,-0.44433922535291914,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-590-144MT-B,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,590.0,561.3,2.58,,,72.0,13.32,53.57,12.62,46.75,0.0055507104000000005,-0.13788382300000002,43.2,1.891701597062775,13.322914441844679,6.590592342663395e-12,0.053944209259610375,246.5435601853446,-0.3284949293593385,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT SURYA PERTAMA INDONESIA LP-590-144MT-W,PT SURYA PERTAMA INDONESIA,Mono-c-Si,0,590.0,561.3,2.58,,,72.0,13.32,53.57,12.62,46.75,0.0055507104000000005,-0.13788382300000002,43.2,1.891701597062775,13.322914441844679,6.590592342663395e-12,0.053944209259610375,246.5435601853446,-0.3284949293593385,-0.29247,N,2025.7.3,6/23/2025,4.0,first_pass +PT Deltamas Solusindo SQF380M-72,PT Deltamas Solusindo,Mono-c-Si,0,380.0,356.8,2.01,,,72.0,10.16,48.16,9.59,39.7,0.0025908,-0.1114904,44.94,1.656540114052415,10.172196826505083,2.365778985965481e-12,0.3385910048878636,282.04751561312906,4.454208128695658,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +PT Deltamas Solusindo SQF385M-72,PT Deltamas Solusindo,Mono-c-Si,0,385.0,361.6,2.01,,,72.0,10.16,48.16,9.59,40.16,0.0025908,-0.1114904,44.94,1.66547331044771,10.170790999452894,2.7620377083688747e-12,0.2839924826120338,267.38613409885335,5.799328852400087,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +PT Deltamas Solusindo SQF390M-72,PT Deltamas Solusindo,Mono-c-Si,0,390.0,366.4,2.01,,,72.0,10.16,48.16,9.59,40.68,0.0025908,-0.1114904,44.94,1.6755419299311793,10.168899978120889,3.2824265276171233e-12,0.2223686715967981,253.85070335171505,7.315707506625798,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +PT Deltamas Solusindo SQF395M-72,PT Deltamas Solusindo,Mono-c-Si,0,395.0,371.2,2.01,,,72.0,10.24,48.88,9.7,40.8,0.0026112,-0.11315720000000001,44.94,1.688443158712763,10.248123542434787,2.704286751270644e-12,0.2815201074781649,354.8656167011668,5.5301421038707375,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +PT Deltamas Solusindo SQF400M-72,PT Deltamas Solusindo,Mono-c-Si,0,400.0,376.0,2.01,,,72.0,10.37,49.32,9.84,40.8,0.0026443499999999997,-0.11417580000000001,44.94,1.6952896809347524,10.377450057833967,2.3813235794141486e-12,0.3230136317621663,449.61414295870793,4.31006623249199,-0.3108,N,2025.7.3,6/23/2025,4.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN420-108(B),PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,420.0,398.3,1.95,,,54.0,13.58,39.66,13.28,31.63,0.0047937399999999995,-0.09522365999999999,43.8,1.3375374534063802,13.580004083557684,1.8005820899701263e-12,0.25750272986104683,856338.2058785019,-4.092584086537229,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN425-108(B),PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,425.0,403.1,1.95,,,54.0,13.68,39.81,13.38,31.77,0.00482904,-0.09558381,43.8,1.3430589481825754,13.680003955361569,1.8324663129950252e-12,0.24944558500753747,862736.2791238215,-4.010972926633735,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN430-108(B),PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,430.0,408.0,1.95,,,54.0,13.78,39.95,13.48,31.9,0.00486434,-0.09591995,43.8,1.3481273420796356,13.780004049991813,1.8599269051961886e-12,0.2514966345604376,855715.9804990701,-3.9502944366844166,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN435-108(B),PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,435.0,412.8,1.95,,,54.0,13.88,40.1,13.58,32.04,0.00489964,-0.09628010000000001,43.8,1.353607035008373,13.880004031732765,1.8906420066685367e-12,0.24848356164847926,855456.1938646911,-3.8771246118791667,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN440-108(B),PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,440.0,417.7,1.95,,,54.0,13.98,40.24,13.68,32.17,0.00493494,-0.09661624,43.8,1.3587153345603598,13.980004016025811,1.920210469956682e-12,0.24564606782933668,855111.7414909073,-3.810385692797996,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN570-144,PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,570.0,542.9,2.58,,,72.0,13.91,51.16,13.4,42.54,0.00460421,-0.12447227999999998,43.2,1.7146628606750969,13.910142657420662,1.5322103972165427e-12,0.23755026322839382,23162.653361233126,-6.778632923278906,-0.2821,N,2025.7.3,6/23/2025,4.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN575-144,PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,575.0,547.7,2.58,,,72.0,13.98,51.31,13.47,42.69,0.0046273799999999995,-0.12483723,43.2,1.7202169538503134,13.98014722650426,1.5540459368747467e-12,0.23489828283642591,22304.937783056896,-6.707546689991088,-0.2821,N,2025.7.3,6/23/2025,4.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN580-144,PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,580.0,552.6,2.58,,,72.0,14.05,51.47,13.54,42.84,0.00465055,-0.12522651,43.2,1.7259310855859855,14.050117209234191,1.5713514212219062e-12,0.23301835154418335,27932.16979524187,-6.660325914065817,-0.2821,N,2025.7.3,6/23/2025,4.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN585-144,PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,585.0,557.4,2.58,,,72.0,14.13,51.62,13.61,42.99,0.0046770299999999996,-0.12559146,43.2,1.7310328590563375,14.130124912632773,1.5822427080366381e-12,0.23039843394771653,26062.458364600425,-6.65071643327369,-0.2821,N,2025.7.3,6/23/2025,4.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN590-144,PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,590.0,562.3,2.58,,,72.0,14.19,51.78,13.68,43.14,0.00469689,-0.12598074,43.2,1.7371949262672715,14.190090267950003,1.6108968067908512e-12,0.22857992837005453,35932.4627842157,-6.544012698913422,-0.2821,N,2025.7.3,6/23/2025,4.0,first_pass +PT JAYA ELECTRICAL ENERGY JAYAEGN595-144,PT JAYA ELECTRICAL ENERGY,Mono-c-Si,0,595.0,567.2,2.58,,,72.0,14.26,51.93,13.75,43.29,0.00472006,-0.12634568999999998,43.2,1.742791299266988,14.260129604801216,1.6344638478068575e-12,0.2260214468383821,24868.41665820319,-6.468955671065134,-0.2821,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS405M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,405.0,380.1,1.95,,,54.0,13.53,38.44,12.75,31.83,0.0061020300000000005,-0.09248664,46.93,1.3302553346592059,13.547176487014916,3.7482692461166085e-12,0.1894517850970355,149.23206669051228,1.6574239096410222,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS410M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,410.0,384.9,1.95,,,54.0,13.6,38.64,12.82,32.03,0.0061336,-0.09296784000000001,46.93,1.3376713603601003,13.616716759264188,3.8091690833716634e-12,0.18640296484590047,151.64903119736823,1.7484718982656278,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS415M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,415.0,389.7,1.95,,,54.0,13.67,38.84,12.89,32.23,0.006165170000000001,-0.09344904000000001,46.93,1.3450864523083954,13.686266284473973,3.870412730111206e-12,0.18338795302531852,154.11714628280478,1.8384154399867143,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS420M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,420.0,394.6,1.95,,,54.0,13.74,39.04,12.96,32.43,0.00619674,-0.09393024000000001,46.93,1.35250061768204,13.7558248896691,3.9319959403097575e-12,0.180406190069161,156.638125551411,1.9272727955969822,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS425M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,425.0,399.3,1.99,,,54.0,13.82,39.25,12.92,32.91,0.006426300000000001,-0.09109925,46.7,1.3725718038320722,13.841994080812718,5.118314010992321e-12,0.15294708241196797,96.10443370224083,7.981859513773229,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS425M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,425.0,399.4,1.95,,,54.0,13.81,39.24,13.03,32.63,0.00622831,-0.09441144000000001,46.93,1.3599138934819057,13.825392440008402,3.993916885528409e-12,0.17745712406712474,159.2134114438086,2.015066994404747,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS430M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,430.0,404.2,1.99,,,54.0,13.89,39.45,12.99,33.11,0.0064588499999999995,-0.09156345,46.7,1.3799843163577106,13.911432377330296,5.190726331190061e-12,0.15013961330909656,97.30321555649759,8.060634956765774,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS430M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,430.0,404.2,1.95,,,54.0,13.88,39.44,13.1,32.83,0.006259880000000001,-0.09489264,46.93,1.367326287557905,13.894968766813102,4.0561715166918385e-12,0.17454022020517962,161.84487940195464,2.1018140473803344,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS435M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,435.0,409.0,1.99,,,54.0,13.96,39.65,13.06,33.31,0.0064914000000000005,-0.09202765,46.7,1.387395961983842,13.980881297145904,5.263431514815816e-12,0.14736284372875597,98.5180799077007,8.13845724369028,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS435M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,435.0,409.0,1.95,,,54.0,13.95,39.64,13.17,33.03,0.00629145,-0.09537384000000002,46.93,1.3747378121243368,13.964553716828867,4.1187562339503006e-12,0.17165495256278226,164.53436738662143,2.1875361728334624,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS440M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,440.0,413.8,1.99,,,54.0,14.03,39.85,13.13,33.51,0.006523950000000001,-0.09249185,46.7,1.3948067560914872,14.050340646738395,5.33642605516493e-12,0.1446162714959536,99.7493500314611,8.21534350710717,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS440M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,440.0,413.8,1.95,,,54.0,14.02,39.84,13.24,33.24,0.0063230199999999995,-0.09585504000000002,46.93,1.3823461115375706,14.034094381491707,4.198820242636495e-12,0.16794100957489155,167.05472026450892,2.306909951685267,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS445M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,445.0,418.6,1.99,,,54.0,14.1,40.05,13.2,33.71,0.006556499999999999,-0.09295605,46.7,1.4022167136188004,14.119810237129988,5.409706486845825e-12,0.1418994053762265,100.99735833132031,8.291310458374149,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS445M10T-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,445.0,418.7,1.95,,,54.0,14.09,40.04,13.31,33.45,0.00635459,-0.09633624,46.93,1.3899531411344184,14.103644848188107,4.279557106826858e-12,0.16426708074215432,169.62615796251723,2.4248730022634986,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS450M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,450.0,423.5,1.99,,,54.0,14.17,40.25,13.27,33.91,0.00658905,-0.09342025000000001,46.7,1.4096258485414515,14.189289883390197,5.483269328763207e-12,0.13921176486371328,102.26244867107371,8.366374306824722,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS455M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,455.0,428.3,1.99,,,54.0,14.24,40.45,13.34,34.11,0.0066216,-0.09388445000000001,46.7,1.4170341777502147,14.258779407181986,5.557111492353714e-12,0.1365528792744484,103.54496196811758,8.44055144993566,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS460M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,460.0,433.1,1.99,,,54.0,14.31,40.65,13.41,34.31,0.00665415,-0.09434864999999999,46.7,1.4244417116036285,14.328278630107503,5.631229280425188e-12,0.13392228898349728,104.84527265835176,8.513856825572248,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS465M10RT-B54yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,465.0,438.0,1.99,,,54.0,14.38,40.85,13.48,34.51,0.0066867,-0.09481285,46.7,1.43184846625115,14.397787382051296,5.705619691213752e-12,0.13131954318534747,106.1637416698701,8.586306080590775,-0.2951,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS555M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,555.0,521.4,2.58,,,72.0,13.69,51.5,12.94,42.9,0.00568135,-0.12272450000000001,46.59,1.7859552607768585,13.703083628072491,4.041707842104522e-12,0.22818507422484247,238.76050693530382,3.226791042580273,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS560M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,560.0,526.2,2.58,,,72.0,13.75,51.7,13.0,43.09,0.00570625,-0.12320110000000001,46.59,1.7931473495413424,13.762803417640049,4.077190191605103e-12,0.2260323630961326,242.74331675297762,3.2630219412597583,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS565M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,565.0,531.0,2.58,,,72.0,13.81,51.9,13.06,43.28,0.00573115,-0.12367770000000002,46.59,1.8003392915641179,13.822527323715379,4.112751710425519e-12,0.22389961906140668,246.82476597901137,3.2989517873111036,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS570M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,570.0,535.9,2.58,,,72.0,13.87,52.1,13.12,43.47,0.0057560499999999995,-0.12415430000000001,46.59,1.807531086251805,13.882255287156044,4.148391581044094e-12,0.22178656580556266,251.008371619364,3.3345843165850266,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS575M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,575.0,540.7,2.58,,,72.0,13.93,52.3,13.18,43.66,0.005780950000000001,-0.12463090000000002,46.59,1.8147227332913551,13.941987248340137,4.184109007579868e-12,0.21969293240348486,255.29816940336104,3.369922436534493,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS580M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,580.0,545.5,2.58,,,72.0,13.99,52.5,13.24,43.85,0.00580585,-0.1251075,46.59,1.821914244248676,14.001723162711238,4.219903939064862e-12,0.21761845062285065,259.6980158271814,3.4049716257656324,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS585M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,585.0,550.3,2.58,,,72.0,14.05,52.7,13.3,44.04,0.005830750000000001,-0.1255841,46.59,1.8291056131906838,14.06146296648821,4.255775257896834e-12,0.21556286015420043,264.2124272930755,3.439734017269949,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS590M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,590.0,555.2,2.58,,,72.0,14.11,52.9,13.36,44.23,0.0058556500000000004,-0.12606070000000003,46.59,1.8362968420654489,14.121206607388414,4.291722330673135e-12,0.21352590407713992,268.84590553412255,3.474213158565988,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS595M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,595.0,560.0,2.58,,,72.0,14.17,53.1,13.42,44.42,0.00588055,-0.12653730000000002,46.59,1.8434879400955937,14.180954038352928,4.327745009592496e-12,0.21150732875509004,273.6031002181474,3.5084139165684527,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS600G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,600.0,564.0,2.7,,,66.0,15.87,48.29,14.97,40.05,0.00756999,-0.11319176,46.57,1.684739167821483,15.887965172301783,5.560509219199567e-12,0.1960844071697567,173.2162282238833,6.362633295145627,-0.2994,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS600M10T-B72yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,600.0,564.8,2.58,,,72.0,14.23,53.3,13.47,44.61,0.0059054500000000005,-0.1270139,46.59,1.8512989993592022,14.241423129128316,4.40232973766434e-12,0.2094653673238503,260.9348162666512,3.6207294891158366,-0.2983,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS600M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,600.0,563.7,2.79,,,78.0,13.7,56.11,12.95,46.34,0.005754,-0.13791838,46.39,1.9482035589687172,13.713897196852763,4.1942026961651075e-12,0.28183504079360594,277.8358907136439,0.3458648093482557,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS605G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,605.0,568.9,2.7,,,66.0,15.93,48.49,15.03,40.25,0.0075986099999999996,-0.11366056000000001,46.57,1.6922258558815286,15.94758245465089,5.630912404893601e-12,0.19357036459576898,175.37801016875025,6.439158925414862,-0.2994,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS605M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,605.0,568.5,2.79,,,78.0,13.75,56.3,13.0,46.53,0.005775000000000001,-0.1383854,46.39,1.9552801815310892,13.76361697350535,4.240109482224931e-12,0.27885895701581537,281.58317747783616,0.40512831632687374,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS610G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,610.0,573.7,2.7,,,66.0,15.99,48.69,15.09,40.45,0.0076272300000000005,-0.11412936,46.57,1.6997115741626154,16.007205647979703,5.701594067160519e-12,0.19107682361384606,177.5764800556341,6.514915191597241,-0.2994,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS610M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,610.0,573.3,2.79,,,78.0,13.81,56.5,13.06,46.72,0.0058002,-0.138877,46.39,1.962501040363586,13.823323418669887,4.276861613989567e-12,0.2764777888971747,286.57496741009425,0.43961679845492013,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS615G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,615.0,578.5,2.7,,,66.0,16.05,48.89,15.15,40.65,0.0076558500000000005,-0.11459816,46.57,1.7071966304293111,16.06683491428357,5.7725782098405875e-12,0.18860350122340425,179.8100155855059,6.58993404512126,-0.2994,N,2025.7.3,6/23/2025,4.0,bootstrapping +PT NUSA SOLAR INDONESIA NS615M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,615.0,578.1,2.79,,,78.0,13.87,56.7,13.12,46.91,0.0058254,-0.1393686,46.39,1.9697218935061822,13.883033859945861,4.3137136016334966e-12,0.2741185505543968,291.70363346633167,0.47385900661222374,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS620G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,620.0,583.4,2.7,,,66.0,16.11,49.09,15.2,40.85,0.00768447,-0.11506696000000001,46.57,1.7151894066498075,16.127260819214502,5.88913488525034e-12,0.1861298391512108,173.72012743509177,6.735142659244217,-0.2994,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS620M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,620.0,583.0,2.79,,,78.0,13.93,56.9,13.18,47.1,0.005850600000000001,-0.1398602,46.39,1.9769427267205897,13.942748235319206,4.3506639322370914e-12,0.2717809430513815,296.9751065737007,0.507855319185332,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS625G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,625.0,588.2,2.7,,,66.0,16.17,49.29,15.25,41.05,0.007713090000000001,-0.11553576,46.57,1.723183776770761,16.18766924637668,6.0072077700407406e-12,0.18367210267462145,168.08741069788957,6.879377787716028,-0.2994,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS625M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,625.0,587.8,2.79,,,78.0,13.99,57.1,13.24,47.29,0.0058758000000000005,-0.1403518,46.39,1.984163544671377,14.002466496981818,4.387712243629451e-12,0.2694646693317295,302.3953501184961,0.5416095262389697,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS630G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,630.0,593.0,2.7,,,66.0,16.23,49.49,15.3,41.25,0.00774171,-0.11600456,46.57,1.731179680457783,16.248060427123608,6.126799524104085e-12,0.18123013480482425,162.86243244539898,7.022664047601825,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +PT NUSA SOLAR INDONESIA NS630M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,630.0,592.6,2.79,,,78.0,14.04,57.3,13.29,47.48,0.005896800000000001,-0.14084339999999998,46.39,1.9914203213128603,14.05222545315969,4.423800067405324e-12,0.26735899582133016,307.04140457504315,0.5792202970399946,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS635G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,635.0,597.9,2.7,,,66.0,16.29,49.69,15.35,41.45,0.00777033,-0.11647336,46.57,1.7391774264474311,16.30843486808951,6.2479481248065916e-12,0.17880373885030398,158.0002027885289,7.1650561956965815,-0.2994,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS635M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,635.0,597.4,2.79,,,78.0,14.09,57.5,13.34,47.67,0.0059178,-0.14133500000000002,46.39,1.998676785797438,14.101987502758114,4.4599586647123365e-12,0.26526934015156883,311.79513312968317,0.6165315731287812,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS640G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,640.0,602.7,2.7,,,66.0,16.33,49.89,15.39,41.64,0.007789409999999998,-0.11694216,46.57,1.7465202333143446,16.34816990874304,6.299285109568106e-12,0.17737465560599314,159.41346603824215,7.215145337762642,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +PT NUSA SOLAR INDONESIA NS640M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,640.0,602.3,2.79,,,78.0,14.14,57.7,13.39,47.86,0.0059388,-0.14182660000000002,46.39,2.0059329265631485,14.151752598127345,4.496186514698259e-12,0.26319552179789374,316.6605906972691,0.653546166965155,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +PT NUSA SOLAR INDONESIA NS645G12RT-B66yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,645.0,607.5,2.7,,,66.0,16.37,50.09,15.43,41.84,0.00780849,-0.11741096,46.57,1.7540619031398936,16.387849988538992,6.371160501703937e-12,0.17521485874279968,160.6873438466469,7.2933267375555255,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +PT NUSA SOLAR INDONESIA NS645M10T-B78yy,PT NUSA SOLAR INDONESIA,Mono-c-Si,0,645.0,607.1,2.79,,,78.0,14.19,57.9,13.44,48.05,0.0059598,-0.14231819999999998,46.39,2.013188785423521,14.201520728777043,4.532485359075182e-12,0.26113735532981686,321.64103022109015,0.6902720359146102,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G3 240,Qcells North America,Multi-c-Si,0,240.0,217.8,1.653022,1.663,0.994,60.0,8.76,37.35,8.2,29.57,0.003504,-0.11952,44.8,1.5017715755904075,8.771661223337276,1.3674546568125438e-10,0.413597837457714,310.69788987377297,5.864075522916896,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR - G3 245,Qcells North America,Multi-c-Si,0,245.0,222.5,1.653022,1.663,0.994,60.0,8.85,37.56,8.32,29.73,0.0035399999999999997,-0.12019200000000002,44.8,1.506794992101055,8.856947330648433,1.3124098115284232e-10,0.41226955673935084,525.1781541099091,5.412061814868768,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G3 245,Qcells North America,Multi-c-Si,0,245.0,222.5,1.653022,1.663,0.994,60.0,8.85,37.56,8.32,29.73,0.0035399999999999997,-0.12019200000000002,44.8,1.506794992101055,8.856947330648433,1.3124098115284232e-10,0.41226955673935084,525.1781541099091,5.412061814868768,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR - G3 250,Qcells North America,Multi-c-Si,0,250.0,227.1,1.653022,1.663,0.994,60.0,8.94,37.78,8.45,29.89,0.0035759999999999998,-0.12089600000000002,44.8,1.511205976562877,8.940843111613798,1.2406210639248986e-10,0.4120530415222461,4369.243385629483,4.830577339991294,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G3 250,Qcells North America,Multi-c-Si,0,250.0,227.1,1.653022,1.663,0.994,60.0,8.94,37.78,8.45,29.89,0.0035759999999999998,-0.12089600000000002,44.8,1.511205976562877,8.940843111613798,1.2406210639248986e-10,0.4120530415222461,4369.243385629483,4.830577339991294,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR - G3 255,Qcells North America,Multi-c-Si,0,255.0,231.8,1.653022,1.663,0.994,60.0,9.03,37.99,8.57,30.04,0.0036119999999999998,-0.12156800000000001,44.8,1.5209984632145197,9.030003606682923,1.2832365360394735e-10,0.39927318644118603,999999.9291828072,5.028208535134978,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO BFR G4 255,Qcells North America,Multi-c-Si,0,255.0,230.8,1.527306,1.606,0.951,60.0,9.07,37.54,8.45,30.18,0.004535,-0.1133708,47.2,1.5024914905382727,9.086917513805739,1.252113918656722e-10,0.34351670754422176,184.16989160883895,11.012165245702912,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR-G41 255,Qcells North America,Multi-c-Si,0,255.0,232.1,1.67,1.67,1.0,60.0,8.99,37.47,8.37,30.45,0.004495000000000001,-0.10866299999999998,47.0,1.4609524445118396,9.007623759046815,6.37513549192162e-11,0.3124058012811487,159.3603388083112,9.608874962431562,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO G41/SC 255,Qcells North America,Multi-c-Si,0,255.0,232.2,1.67,1.67,1.0,60.0,8.99,37.47,8.37,30.45,0.004495000000000001,-0.10866299999999998,46.9,1.4609524445118396,9.007623759046815,6.37513549192162e-11,0.3124058012811487,159.3603388083112,9.608874962431562,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G3 255,Qcells North America,Multi-c-Si,0,255.0,231.8,1.653022,1.663,0.994,60.0,9.03,37.99,8.57,30.04,0.0036119999999999998,-0.12156800000000001,44.8,1.5209984632145197,9.030003606682923,1.2832365360394735e-10,0.39927318644118603,999999.9291828072,5.028208535134978,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO-G4 255,Qcells North America,Multi-c-Si,0,255.0,230.8,1.527306,1.606,0.951,60.0,9.07,37.54,8.45,30.18,0.004535,-0.1133708,47.2,1.5024914905382727,9.086917513805739,1.252113918656722e-10,0.34351670754422176,184.16989160883895,11.012165245702912,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G4/SC 255,Qcells North America,Multi-c-Si,0,255.0,232.0,1.598639,1.643,0.973,60.0,9.07,37.54,8.45,30.18,0.003628,-0.12012800000000001,44.8,1.5262417697608253,9.085940875183471,1.8486836227025182e-10,0.33766003676242967,192.12099253277302,8.184320915810039,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR - G3 260,Qcells North America,Multi-c-Si,0,260.0,236.5,1.653022,1.663,0.994,60.0,9.12,38.21,8.7,30.18,0.0036479999999999998,-0.122272,44.8,1.5325854325548833,9.120003473772686,1.356070222695556e-10,0.38076364877027885,999989.4499373412,5.411331403997453,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO BFR G4 260,Qcells North America,Multi-c-Si,0,260.0,235.4,1.527306,1.606,0.951,60.0,9.15,37.77,8.53,30.46,0.004575000000000001,-0.11406540000000001,47.2,1.5138330933039013,9.166046779548116,1.3090104766021043e-10,0.32951231189215785,187.8905234857299,11.330469231799967,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR-G41 260,Qcells North America,Multi-c-Si,0,260.0,236.8,1.67,1.67,1.0,60.0,9.07,37.7,8.46,30.74,0.004535,-0.10933000000000001,47.0,1.4712346737940603,9.085672681321523,6.592907414707406e-11,0.2973998938181842,172.10948528919832,9.821850751447453,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR-G43 260,Qcells North America,Multi-c-Si,0,260.0,233.9,1.67,1.67,1.0,60.0,8.85,38.1,8.48,30.7,0.004425,-0.11811,47.94,1.5246199126555997,8.85024019862454,1.241191464206901e-10,0.30058526126051605,11074.94270483787,8.199558515890619,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO G41/SC 260,Qcells North America,Multi-c-Si,0,260.0,236.9,1.67,1.67,1.0,60.0,9.07,37.7,8.46,30.74,0.004535,-0.10933000000000001,46.9,1.4712346737940603,9.085672681321523,6.592907414707406e-11,0.2973998938181842,172.10948528919832,9.821850751447453,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G3 260,Qcells North America,Multi-c-Si,0,260.0,236.5,1.653022,1.663,0.994,60.0,9.12,38.21,8.7,30.18,0.0036479999999999998,-0.122272,44.8,1.5325854325548833,9.120003473772686,1.356070222695556e-10,0.38076364877027885,999989.4499373412,5.411331403997453,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO-G4 260,Qcells North America,Multi-c-Si,0,260.0,235.4,1.527306,1.606,0.951,60.0,9.15,37.77,8.53,30.46,0.004575000000000001,-0.11406540000000001,47.2,1.5138330933039013,9.166046779548116,1.3090104766021043e-10,0.32951231189215785,187.8905234857299,11.330469231799967,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G4/SC 260,Qcells North America,Multi-c-Si,0,260.0,236.7,1.598639,1.643,0.973,60.0,9.15,37.77,8.53,30.46,0.0036600000000000005,-0.12086400000000001,44.8,1.5378023130128895,9.165098106819016,1.932847768083996e-10,0.32364343466400725,196.13966737570382,8.494666093850805,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G3 265,Qcells North America,Mono-c-Si,0,265.0,237.2,1.653022,1.663,0.994,60.0,9.08,38.22,8.6,31.1,0.0088076,-0.1307124,49.1,1.604561564913067,9.080931090172646,4.105931282994345e-10,0.27969294387717,999999.9262270625,7.164925975083772,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK-G3 265,Qcells North America,Mono-c-Si,0,265.0,237.9,1.653022,1.663,0.994,60.0,9.15,37.91,8.65,30.94,0.009058500000000002,-0.13230589999999998,46.8,1.6488419696653425,9.150344020165877,9.460498175015379e-10,0.250010659719389,6649.6549632281885,12.29247417053242,-0.454,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR - G3 265,Qcells North America,Multi-c-Si,0,265.0,241.1,1.653022,1.663,0.994,60.0,9.21,38.43,8.82,30.32,0.0036840000000000006,-0.12297600000000002,44.8,1.5437654063588078,9.21031270746715,1.422061664599807e-10,0.3648709487302253,10746.380125104442,5.732447705901096,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO BFR G4 265,Qcells North America,Multi-c-Si,0,265.0,240.1,1.527306,1.606,0.951,60.0,9.23,38.01,8.62,30.75,0.004615,-0.1147902,47.2,1.524714307004782,9.244158349153007,1.350395195160465e-10,0.31563657830058256,205.76733532757845,11.526149369301205,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR-G41 265,Qcells North America,Multi-c-Si,0,265.0,241.4,1.67,1.67,1.0,60.0,9.15,37.93,8.54,31.03,0.004575000000000001,-0.109997,47.0,1.4823918295269263,9.164756174315936,6.909358150404845e-11,0.28264606173797635,175.26300968888424,10.158687421697557,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO BFR-G43 265,Qcells North America,Multi-c-Si,0,265.0,238.5,1.67,1.67,1.0,60.0,8.98,38.2,8.61,30.8,0.00449,-0.11842000000000001,47.94,1.5295006976733974,8.980237260021125,1.2776481465253327e-10,0.291643249884803,11038.36509162234,8.324848683445246,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO G41/SC 265,Qcells North America,Multi-c-Si,0,265.0,241.5,1.67,1.67,1.0,60.0,9.15,37.93,8.54,31.03,0.004575000000000001,-0.109997,46.9,1.4823918295269263,9.164756174315936,6.909358150404845e-11,0.28264606173797635,175.26300968888424,10.158687421697557,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G3 265,Qcells North America,Multi-c-Si,0,265.0,241.1,1.653022,1.663,0.994,60.0,9.21,38.43,8.82,30.32,0.0036840000000000006,-0.12297600000000002,44.8,1.5437654063588078,9.21031270746715,1.422061664599807e-10,0.3648709487302253,10746.380125104442,5.732447705901096,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO-G4 265,Qcells North America,Multi-c-Si,0,265.0,240.1,1.527306,1.606,0.951,60.0,9.23,38.01,8.62,30.75,0.004615,-0.1147902,47.2,1.524714307004782,9.244158349153007,1.350395195160465e-10,0.31563657830058256,205.76733532757845,11.526149369301205,-0.419,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO-G4/SC 265,Qcells North America,Multi-c-Si,0,265.0,241.3,1.598639,1.643,0.973,60.0,9.23,38.01,8.62,30.75,0.0036920000000000004,-0.121632,44.8,1.5488767596922781,9.243257294268984,1.9939739606095895e-10,0.30977003493404887,215.6682682843445,8.685020966839625,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G3 270,Qcells North America,Mono-c-Si,0,270.0,241.8,1.653022,1.663,0.994,60.0,9.14,38.51,8.67,31.42,0.008865800000000002,-0.13170420000000002,49.1,1.6188578001860106,9.152446900740806,4.2694746071647543e-10,0.2682523369287418,999999.9799289444,7.438934781044182,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK-G3 270,Qcells North America,Mono-c-Si,0,270.0,242.5,1.653022,1.663,0.994,60.0,9.25,38.21,8.75,31.16,0.0091575,-0.1333529,46.8,1.6607254340112527,9.251986927712226,9.418421827263736e-10,0.25262972668355493,999999.603345057,12.148571287771954,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPLUS BFR G31 270,Qcells North America,Multi-c-Si,0,270.0,247.3,1.67,1.67,1.0,60.0,9.29,38.46,8.7,31.04,0.003716,-0.111534,45.39,1.4919104884511913,9.303720523109568,5.821931064989718e-11,0.33866763245669307,229.30775867915142,8.62214423356941,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR G41 270,Qcells North America,Multi-c-Si,0,270.0,247.3,1.67,1.67,1.0,60.0,9.29,38.46,8.7,31.04,0.003716,-0.111534,45.39,1.4919104884511913,9.303720523109568,5.821931064989718e-11,0.33866763245669307,229.30775867915142,8.62214423356941,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS G4 270,Qcells North America,Multi-c-Si,0,270.0,246.1,1.665,1.665,1.0,60.0,9.43,38.65,8.84,30.53,0.0037719999999999997,-0.11208499999999999,46.5,1.4813479721276164,9.444017457384385,4.34153903723479e-11,0.422966035255841,284.5430361156742,5.9442831127798605,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G3 270,Qcells North America,Multi-c-Si,0,270.0,246.1,1.5344,1.6,0.959,60.0,9.48,38.86,8.85,30.78,0.0005688000000000001,-0.1239634,46.6,1.4577683815912956,9.501035736711287,2.4617291572131295e-11,0.42108566049274926,189.76716545834452,-7.612534958113445,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G41/SC 270,Qcells North America,Multi-c-Si,0,270.0,247.0,1.6268799999999999,1.64,0.992,60.0,9.3,38.53,8.72,30.98,0.0037200000000000006,-0.10788400000000002,45.83,1.488427322118036,9.31291357955198,5.244302420157945e-11,0.35505172691687575,255.69836442979332,11.564844596454503,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G3 275,Qcells North America,Mono-c-Si,0,275.0,246.5,1.653022,1.663,0.994,60.0,9.21,38.8,8.74,31.73,0.008933700000000001,-0.132696,49.1,1.6330132177036991,9.224299835296113,4.4279172029146835e-10,0.258304129477037,999999.9802249591,7.689708361889151,-0.421,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK-G3 275,Qcells North America,Mono-c-Si,0,275.0,247.1,1.653022,1.663,0.994,60.0,9.35,38.51,8.85,31.37,0.0092565,-0.1343999,46.8,1.6726932340662153,9.358715284898912,9.387732061786064e-10,0.25635267589827415,999999.964171482,12.014412750796316,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPLUS BFR G31 275,Qcells North America,Multi-c-Si,0,275.0,252.0,1.67,1.67,1.0,60.0,9.35,38.72,8.77,31.36,0.0037400000000000003,-0.11228799999999999,45.39,1.5036665975329895,9.36200970111901,6.038648797869757e-11,0.3241062287810159,252.3287888968998,8.880816927365839,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR G41 275,Qcells North America,Multi-c-Si,0,275.0,252.0,1.67,1.67,1.0,60.0,9.35,38.72,8.77,31.36,0.0037400000000000003,-0.11228799999999999,45.39,1.5036665975329895,9.36200970111901,6.038648797869757e-11,0.3241062287810159,252.3287888968998,8.880816927365839,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS G4 275,Qcells North America,Multi-c-Si,0,275.0,250.7,1.665,1.665,1.0,60.0,9.49,38.9,8.91,30.85,0.003796,-0.11281,46.5,1.4930089837994682,9.502114447330857,4.536939393627446e-11,0.4067445399369133,318.6283046953237,6.262083387814005,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G3 275,Qcells North America,Multi-c-Si,0,275.0,250.8,1.5344,1.6,0.959,60.0,9.55,39.14,8.93,31.08,0.0005730000000000002,-0.12485660000000001,46.6,1.469054824239402,9.568894299648615,2.5195171363632363e-11,0.41061436862864015,207.54234682777903,-7.500336883587039,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G41/SC 275,Qcells North America,Multi-c-Si,0,275.0,251.7,1.6268799999999999,1.64,0.992,60.0,9.36,38.78,8.79,31.3,0.0037440000000000004,-0.10858400000000001,45.83,1.499979673826577,9.371196969969533,5.4613325923553415e-11,0.33923289239852406,283.5785033680147,11.866880500347046,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PEAK BLK-G41 280,Qcells North America,Multi-c-Si,0,280.0,256.5,1.67,1.67,1.0,60.0,9.49,38.62,8.89,31.5,0.0037011,-0.1112256,45.97,1.4915225542157788,9.50315595245024,5.2996857520481434e-11,0.293106615194343,211.43142998954178,8.388544881861478,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G3 280,Qcells North America,Mono-c-Si,0,280.0,251.8,1.653022,1.663,0.994,60.0,9.45,38.81,8.95,31.58,0.009355500000000001,-0.1354469,46.8,1.6846608449615603,9.465455696128565,9.357871773326128e-10,0.25999313913389877,999999.8554629392,11.88230390725236,-0.454,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPLUS BFR G31 280,Qcells North America,Multi-c-Si,0,280.0,256.7,1.67,1.67,1.0,60.0,9.41,38.97,8.84,31.67,0.0037640000000000004,-0.11301299999999999,45.39,1.514971526180616,9.42041789334484,6.253702740446716e-11,0.30995664197032524,279.96947244233695,9.126767173156857,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR G41 280,Qcells North America,Multi-c-Si,0,280.0,256.7,1.67,1.67,1.0,60.0,9.41,38.97,8.84,31.67,0.0037640000000000004,-0.11301299999999999,45.39,1.514971526180616,9.42041789334484,6.253702740446716e-11,0.30995664197032524,279.96947244233695,9.126767173156857,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR-G41/TAA 280,Qcells North America,Multi-c-Si,0,280.0,256.7,1.67,1.67,1.0,60.0,9.41,38.97,8.84,31.67,0.0037640000000000004,-0.11301299999999999,45.39,1.514971526180616,9.42041789334484,6.253702740446716e-11,0.30995664197032524,279.96947244233695,9.126767173156857,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS G4 280,Qcells North America,Multi-c-Si,0,280.0,255.4,1.665,1.665,1.0,60.0,9.55,39.16,8.99,31.16,0.003820000000000001,-0.11356399999999997,46.5,1.5037743339972414,9.559009799559483,4.640857475920112e-11,0.3931367123006694,416.70792119972634,6.393013164929987,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G3 280,Qcells North America,Multi-c-Si,0,280.0,255.5,1.5344,1.6,0.959,60.0,9.62,39.41,9.0,31.38,0.0005771999999999999,-0.1257179,46.6,1.4809371639192754,9.638178729742028,2.6198068505878385e-11,0.3993085768766821,211.31006580773894,-7.265399935081179,-0.407,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G41/SC 280,Qcells North America,Multi-c-Si,0,280.0,256.7,1.67,1.67,1.0,60.0,9.41,38.97,8.84,31.67,0.0037640000000000004,-0.11301299999999999,45.39,1.514971526180616,9.42041789334484,6.253702740446716e-11,0.30995664197032524,279.96947244233695,9.126767173156857,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G43 280,Qcells North America,Multi-c-Si,0,280.0,256.7,1.67,,,60.0,9.41,38.97,8.84,31.67,0.0037640000000000004,-0.11301299999999999,45.39,1.514971526180616,9.42041789334484,6.253702740446716e-11,0.30995664197032524,279.96947244233695,9.126767173156857,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR-G41 282,Qcells North America,Multi-c-Si,0,282.0,258.6,1.67,,,60.0,9.5,39.1,9.0,31.4,0.0038,-0.11338999999999999,45.39,1.504251418093342,9.502250719579628,4.875551100856444e-11,0.3567640392033046,1505.8557465020078,6.839793381104945,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PEAK BLK-G41 285,Qcells North America,Multi-c-Si,0,285.0,261.2,1.67,1.67,1.0,60.0,9.56,38.91,8.98,31.73,0.0037284,-0.11206079999999999,45.97,1.5005214102297955,9.570922544895517,5.1565051162449234e-11,0.294085139482342,257.3991755090401,8.074369068179612,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PEAK BLK-G41/SC 285,Qcells North America,Multi-c-Si,0,285.0,261.2,1.67,1.67,1.0,60.0,9.56,38.91,8.98,31.73,0.0037284,-0.11206079999999999,45.97,1.5005214102297955,9.570922544895517,5.1565051162449234e-11,0.294085139482342,257.3991755090401,8.074369068179612,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41 285,Qcells North America,Multi-c-Si,0,285.0,261.2,1.67,1.67,1.0,60.0,9.56,38.91,8.98,31.73,0.0037284,-0.11206079999999999,45.97,1.5005214102297955,9.570922544895517,5.1565051162449234e-11,0.294085139482342,257.3991755090401,8.074369068179612,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/SC 285,Qcells North America,Multi-c-Si,0,285.0,261.2,1.67,1.67,1.0,60.0,9.56,38.91,8.98,31.73,0.0037284,-0.11206079999999999,45.97,1.5005214102297955,9.570922544895517,5.1565051162449234e-11,0.294085139482342,257.3991755090401,8.074369068179612,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/TAA 285,Qcells North America,Multi-c-Si,0,285.0,261.2,1.67,1.67,1.0,60.0,9.56,38.91,8.98,31.73,0.0037284,-0.11206079999999999,45.97,1.5005214102297955,9.570922544895517,5.1565051162449234e-11,0.294085139482342,257.3991755090401,8.074369068179612,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR-G41 285,Qcells North America,Multi-c-Si,0,285.0,261.4,1.67,,,60.0,9.46,39.22,8.91,31.99,0.003784000000000001,-0.11373799999999999,45.39,1.5257172619058066,9.46801442335184,6.413780771962753e-11,0.29508728616955104,348.3127507963817,9.293092239940725,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR-G41/TAA 285,Qcells North America,Multi-c-Si,0,285.0,261.4,1.67,1.67,1.0,60.0,9.46,39.22,8.91,31.99,0.003784000000000001,-0.11373799999999999,45.39,1.5257172619058066,9.46801442335184,6.413780771962753e-11,0.29508728616955104,348.3127507963817,9.293092239940725,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G41/SC 285,Qcells North America,Multi-c-Si,0,285.0,261.4,1.67,1.67,1.0,60.0,9.46,39.22,8.91,31.99,0.003784000000000001,-0.11373799999999999,45.39,1.5257172619058066,9.46801442335184,6.413780771962753e-11,0.29508728616955104,348.3127507963817,9.293092239940725,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G43 285,Qcells North America,Multi-c-Si,0,285.0,261.4,1.67,,,60.0,9.46,39.22,8.91,31.99,0.003784000000000001,-0.11373799999999999,45.39,1.5257172619058066,9.46801442335184,6.413780771962753e-11,0.29508728616955104,348.3127507963817,9.293092239940725,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G31 290,Qcells North America,Mono-c-Si,0,290.0,265.1,1.67,1.67,1.0,60.0,9.63,39.19,9.07,31.96,0.0042372,-0.11365099999999999,45.84,1.543032421519012,9.637593228265636,8.888804197514485e-11,0.2859967637496593,362.71122162017707,11.988299805545413,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41 290,Qcells North America,Mono-c-Si,0,290.0,265.9,1.67,,,60.0,9.63,38.19,9.07,31.96,0.0037557000000000003,-0.10998719999999998,45.97,1.4911950480511857,9.636569645978632,7.161459786723885e-11,0.18213099893278684,266.9735276516713,10.903800046721994,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/SC 290,Qcells North America,Mono-c-Si,0,290.0,265.9,1.67,,,60.0,9.63,39.19,9.07,31.96,0.0037557000000000003,-0.11286719999999999,45.97,1.5093621987031836,9.638660979742717,5.03840241870272e-11,0.293914247802219,326.79840557872603,7.7983899226772895,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/TAA 290,Qcells North America,Mono-c-Si,0,290.0,265.9,1.67,,,60.0,9.63,39.19,9.07,31.96,0.0037557000000000003,-0.11286719999999999,45.97,1.5093621987031836,9.638660979742717,5.03840241870272e-11,0.293914247802219,326.79840557872603,7.7983899226772895,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5 290,Qcells North America,Mono-c-Si,0,290.0,266.2,1.621,,,120.0,9.61,38.94,9.14,31.71,0.004516699999999999,-0.11097899999999998,47.39,1.4603194603036893,9.61081685523794,2.521366326199843e-11,0.30602073713785327,3600.2215218998,2.9009841829723775,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G41 290,Qcells North America,Mono-c-Si,0,290.0,267.9,1.67,,,60.0,9.63,39.19,9.07,31.96,0.0043335000000000005,-0.109732,44.89,1.4946047841316294,9.639144725400161,3.897062768143834e-11,0.29740572883625616,313.18789517171206,8.548979857030007,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR-G41 290,Qcells North America,Multi-c-Si,0,290.0,266.1,1.67,,,60.0,9.52,39.48,8.98,32.29,0.0038079999999999998,-0.11449199999999998,45.39,1.5369213581328036,9.526706277098448,6.582932225150228e-11,0.28383736354445116,402.9257646852585,9.461392187562202,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-BFR G41/TAA 290,Qcells North America,Multi-c-Si,0,290.0,266.1,1.67,1.67,1.0,60.0,9.52,39.48,8.98,32.29,0.0038079999999999998,-0.11449199999999998,45.39,1.5369213581328036,9.526706277098448,6.582932225150228e-11,0.28383736354445116,402.9257646852585,9.461392187562202,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS-G43 290,Qcells North America,Multi-c-Si,0,290.0,266.1,1.67,,,60.0,9.52,39.48,8.98,32.29,0.0038079999999999998,-0.11449199999999998,45.39,1.5369213581328036,9.526706277098448,6.582932225150228e-11,0.28383736354445116,402.9257646852585,9.461392187562202,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L 290,Qcells North America,Multi-c-Si,0,290.0,258.3,1.932528,1.956,0.988,72.0,8.65,45.0,8.2,35.4,0.004238500000000001,-0.14355,47.7,1.844947456267795,8.650004375754408,2.2088389661129352e-10,0.5056190417239904,999999.759145957,10.337862843626612,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK BLK-G31 295,Qcells North America,Mono-c-Si,0,295.0,269.8,1.67,1.67,1.0,60.0,9.7,39.48,9.17,32.19,0.004267999999999999,-0.11449199999999998,45.84,1.5514076351851984,9.704446983772474,8.556092285400363e-11,0.28701457592450275,626.0516779407745,11.563991570850998,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41 295,Qcells North America,Mono-c-Si,0,295.0,270.6,1.67,,,60.0,9.7,39.48,9.17,32.19,0.0037829999999999995,-0.11370239999999998,45.97,1.5175953956959287,9.705439651401768,4.8477619888025155e-11,0.29487117251119277,525.8150394893171,7.385683419950974,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/SC 295,Qcells North America,Mono-c-Si,0,295.0,270.6,1.67,,,60.0,9.7,39.48,9.17,32.19,0.0037829999999999995,-0.11370239999999998,45.97,1.5175953956959287,9.705439651401768,4.8477619888025155e-11,0.29487117251119277,525.8150394893171,7.385683419950974,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/TAA 295,Qcells North America,Mono-c-Si,0,295.0,270.6,1.67,,,60.0,9.7,39.48,9.17,32.19,0.0037829999999999995,-0.11370239999999998,45.97,1.5175953956959287,9.705439651401768,4.8477619888025155e-11,0.29487117251119277,525.8150394893171,7.385683419950974,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G31 295,Qcells North America,Multi-c-Si,0,295.0,269.8,1.67,1.67,1.0,60.0,9.7,39.48,9.17,32.19,0.004267999999999999,-0.11449199999999998,45.84,1.5514076351851984,9.704446983772474,8.556092285400363e-11,0.28701457592450275,626.0516779407745,11.563991570850998,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G41/SC 295,Qcells North America,Multi-c-Si,0,295.0,269.8,1.67,1.67,1.0,60.0,9.7,39.48,9.17,32.19,0.004267999999999999,-0.11449199999999998,45.84,1.5514076351851984,9.704446983772474,8.556092285400363e-11,0.28701457592450275,626.0516779407745,11.563991570850998,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G41 295,Qcells North America,Mono-c-Si,0,295.0,272.6,1.67,,,60.0,9.7,39.48,9.17,32.19,0.004364999999999999,-0.110544,44.89,1.5027926729969951,9.705889791420994,3.750040511389436e-11,0.2983318288846492,491.3278995416331,8.133650962046845,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS BFR-G41 295,Qcells North America,Multi-c-Si,0,295.0,270.8,1.67,,,60.0,9.58,39.73,9.05,32.59,0.003832,-0.11521699999999999,45.39,1.5479342559296643,9.585481279084506,6.776444445022872e-11,0.2716483624010633,474.7781334139492,9.656368175403268,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L 295,Qcells North America,Multi-c-Si,0,295.0,262.9,1.932528,1.956,0.988,72.0,8.73,45.2,8.29,35.6,0.004277700000000001,-0.144188,47.7,1.8556226561303237,8.730004273126571,2.302996319513808e-10,0.4892316597544218,999990.5654422352,10.627553671773326,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK BLK-G41 300,Qcells North America,Mono-c-Si,0,300.0,275.3,1.67,,,60.0,9.77,39.76,9.26,32.41,0.0038103,-0.1145088,45.97,1.5262381557116667,9.773166283934195,4.723882439743278e-11,0.29592791412426594,913.125930704927,7.089020970473089,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41/TAA 300,Qcells North America,Mono-c-Si,0,300.0,275.3,1.67,,,60.0,9.77,39.76,9.26,32.41,0.0038103,-0.1145088,45.97,1.5262381557116667,9.773166283934195,4.723882439743278e-11,0.29592791412426594,913.125930704927,7.089020970473089,-0.392,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5 300,Qcells North America,Mono-c-Si,0,300.0,277.9,1.62,,,120.0,9.72,39.48,9.25,32.43,0.0036936000000000004,-0.1093596,45.57,1.4632708135954782,9.721467420742881,1.858755678769918e-11,0.27726059395560954,1836.5374533725453,3.337381938736108,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G31 300,Qcells North America,Multi-c-Si,0,300.0,274.5,1.67,1.67,1.0,60.0,9.77,39.76,9.26,32.41,0.004298799999999999,-0.11530399999999999,45.84,1.5602125133468763,9.77222214549953,8.339930647667461e-11,0.28811625355145487,1266.746993744845,11.258917342842444,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G41/ Max 300,Qcells North America,Multi-c-Si,0,300.0,274.6,1.641408,1.648,0.996,60.0,9.77,35.0,9.26,32.41,0.004298799999999999,-0.1015,45.84,1.5660422893052355,9.77000028552587,1.2207857166854321e-09,0.0009999900012762964,34218.10866280209,-100.00000099292167,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK G41/SC 300,Qcells North America,Multi-c-Si,0,300.0,274.5,1.67,1.67,1.0,60.0,9.77,39.76,9.26,32.41,0.004298799999999999,-0.11530399999999999,45.84,1.5602125133468763,9.77222214549953,8.339930647667461e-11,0.28811625355145487,1266.746993744845,11.258917342842444,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G41/TAA 300,Qcells North America,Multi-c-Si,0,300.0,274.5,1.67,1.67,1.0,60.0,9.77,39.76,9.26,32.41,0.004298799999999999,-0.11530399999999999,45.84,1.5602125133468763,9.77222214549953,8.339930647667461e-11,0.28811625355145487,1266.746993744845,11.258917342842444,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G41 300,Qcells North America,Mono-c-Si,0,300.0,277.6,1.61,,,60.0,9.77,39.76,9.26,32.41,0.004396499999999999,-0.11132800000000001,44.89,1.511376037071104,9.773594755364963,3.654485486368401e-11,0.2993660930974826,813.631632480842,7.835012742744096,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L 300,Qcells North America,Multi-c-Si,0,300.0,267.5,1.932528,1.956,0.988,72.0,8.82,45.4,8.38,35.8,0.0043218,-0.144826,47.7,1.86531486069376,8.820004220104394,2.3721901920122644e-10,0.47823858778513634,999999.8333803102,10.800165022414916,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO L-G3 300,Qcells North America,Multi-c-Si,0,300.0,272.2,1.972,1.972,1.0,72.0,8.92,44.9,8.31,36.09,0.00446,-0.1347,46.6,1.7796853575751084,8.937287852782916,9.642762931710692e-11,0.42310372991273143,218.30851512634433,9.579278322821358,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK BLK-G41 305,Qcells North America,Mono-c-Si,0,305.0,281.3,1.62,,,60.0,9.84,40.05,9.35,32.62,0.004132800000000001,-0.109737,46.52,1.4942747567038182,9.841973263451719,2.2482330149234572e-11,0.3085939678062026,1538.8542333074759,5.938045479066556,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5 305,Qcells North America,Mono-c-Si,0,305.0,280.3,1.621,,,120.0,9.78,39.75,9.31,32.78,0.0045966,-0.1132875,47.39,1.4997958584233382,9.780854510876672,3.015808486878082e-11,0.256018375017255,2930.1676029319024,4.254842883602906,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5 305,Qcells North America,Mono-c-Si,0,305.0,281.7,1.63,,,120.0,9.93,39.35,9.44,32.3,0.003972,-0.110967,45.48,1.490780821996548,9.93151392425847,3.4086325876018364e-11,0.2659259988917122,1744.2388179349705,6.381034624593168,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G31 305,Qcells North America,Multi-c-Si,0,305.0,279.2,1.67,1.67,1.0,60.0,9.84,40.05,9.35,32.62,0.004329599999999999,-0.11614499999999998,45.84,1.5690837046558246,9.840003596822422,8.08844161824621e-11,0.29149472978887936,797549.7840605093,10.91043700420363,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G41/ Max 305,Qcells North America,Multi-c-Si,0,305.0,279.3,1.641408,1.648,0.996,60.0,9.84,35.0,9.35,32.62,0.004329599999999999,-0.1015,45.84,1.086249751064911,9.840000308310344,9.990000001695195e-14,0.0009999900006181512,31915.57652057205,-36.403196023067814,-0.408,N,2025.7.3,6/23/2025,2.0,bootstrapping +Qcells North America QPEAK G41/SC 305,Qcells North America,Multi-c-Si,0,305.0,279.2,1.67,1.67,1.0,60.0,9.84,40.05,9.35,32.62,0.004329599999999999,-0.11614499999999998,45.84,1.5690837046558246,9.840003596822422,8.08844161824621e-11,0.29149472978887936,797549.7840605093,10.91043700420363,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK G41/TAA 305,Qcells North America,Multi-c-Si,0,305.0,279.2,1.67,1.67,1.0,60.0,9.84,40.05,9.35,32.62,0.004329599999999999,-0.11614499999999998,45.84,1.5690837046558246,9.840003596822422,8.08844161824621e-11,0.29149472978887936,797549.7840605093,10.91043700420363,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G41 305,Qcells North America,Mono-c-Si,0,305.0,282.1,1.67,,,60.0,9.84,40.05,9.35,32.62,0.004428,-0.11214,44.89,1.5180966591421234,9.840008299603426,3.4320642606491345e-11,0.3030701809301556,358942.50181146327,7.211234930814284,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L 305,Qcells North America,Multi-c-Si,0,305.0,272.1,1.932528,1.956,0.988,72.0,8.9,45.5,8.45,36.1,0.004361,-0.145145,47.7,1.8741109925525699,8.900004011082782,2.5439543179310297e-10,0.45046916678383386,999999.9431101172,11.34512898331337,-0.458,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO L-G2 305,Qcells North America,Multi-c-Si,0,305.0,274.6,1.7372480000000001,1.864,0.932,72.0,8.99,45.14,8.38,36.39,0.0031465000000000004,-0.1503162,46.5,1.8705478703321952,9.003923359741046,2.919169764528797e-10,0.38742618292899844,250.15238468526425,7.961733012500897,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G23 305,Qcells North America,Multi-c-Si,0,305.0,276.0,1.912936,1.948,0.982,72.0,8.92,45.06,8.32,36.66,0.00446,-0.139686,46.9,1.818821421389037,8.933867459781203,1.5207442082684712e-10,0.35689474807145305,229.56629181231145,9.982461608900516,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G3 305,Qcells North America,Multi-c-Si,0,305.0,276.8,1.972,1.972,1.0,72.0,8.99,45.14,8.38,36.39,0.004495000000000001,-0.13542,46.6,1.791597668792752,9.006486459880579,1.005584553645886e-10,0.40706566962282215,221.97127498188524,9.880171386830762,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PRO L-G41 307,Qcells North America,Multi-c-Si,0,308.0,284.6,1.994,1.994,1.0,72.0,8.96,45.2,8.35,36.8,0.0035840000000000004,-0.13108,43.2,1.765998908550509,8.976364140407778,6.706907568322951e-11,0.3679272003946337,201.45438179146012,10.210887130534818,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5 310,Qcells North America,Mono-c-Si,0,310.0,287.4,1.62,,,60.0,9.83,40.02,9.36,33.12,0.0037354,-0.11085540000000002,45.57,1.4885148120880896,9.83136557225276,2.0665240613896625e-11,0.24760631940571898,1782.381171600886,4.132358892306583,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5/SC 310,Qcells North America,Mono-c-Si,0,310.0,287.4,1.62,,,60.0,9.83,40.02,9.36,33.12,0.0037354,-0.11085540000000002,45.57,1.4885148120880896,9.83136557225276,2.0665240613896625e-11,0.24760631940571898,1782.381171600886,4.132358892306583,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5 310,Qcells North America,Mono-c-Si,0,310.0,286.5,1.62,,,60.0,9.98,39.61,9.5,32.64,0.003992,-0.11170019999999999,45.48,1.5026969176726717,9.980659460207717,3.5564600254670936e-11,0.25099104460532423,3798.3962337572166,6.698584233820516,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G41 310,Qcells North America,Mono-c-Si,0,310.0,287.1,1.61,,,60.0,9.91,40.33,9.44,32.83,0.0044595,-0.11292400000000001,44.89,1.5299633422463292,9.910003781107047,3.532009456383907e-11,0.3045393951527833,798221.2255292808,7.398520539091364,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L 310,Qcells North America,Multi-c-Si,0,310.0,283.8,1.932528,1.956,0.988,72.0,9.08,45.75,8.65,36.15,0.004540000000000001,-0.1464,43.6,1.8508102835358458,9.08000415280824,1.6703237521674577e-10,0.4572023632135426,999999.0301945666,7.1108696173088,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO L G4 310,Qcells North America,Multi-c-Si,0,310.0,283.4,1.994,1.994,1.0,72.0,8.99,45.29,8.39,36.96,0.0035960000000000002,-0.140399,45.1,1.7949808873482123,9.004141462667143,9.696228080143565e-11,0.3492195652408133,222.0056063250758,6.128043853474627,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L G41 310,Qcells North America,Multi-c-Si,0,310.0,283.4,1.994,1.994,1.0,72.0,8.99,45.29,8.39,36.96,0.0035960000000000002,-0.140399,45.1,1.7949808873482123,9.004141462667143,9.696228080143565e-11,0.3492195652408133,222.0056063250758,6.128043853474627,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G2 310,Qcells North America,Multi-c-Si,0,310.0,279.3,1.7372480000000001,1.864,0.932,72.0,9.06,45.37,8.45,36.68,0.003171,-0.1510821,46.5,1.8826074603305356,9.073220364721509,3.039839575018135e-10,0.3718141886904792,254.80665664241275,8.245558203477161,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G23 310,Qcells North America,Multi-c-Si,0,310.0,280.6,1.912936,1.948,0.982,72.0,8.99,45.29,8.39,36.96,0.004495000000000001,-0.140399,46.9,1.8307009604281186,9.003104521291286,1.587994718944221e-10,0.34019444696545925,233.38115369999264,10.296238039758725,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G3 310,Qcells North America,Multi-c-Si,0,310.0,281.5,1.972,1.972,1.0,72.0,9.06,45.37,8.45,36.68,0.00453,-0.13610999999999998,46.6,1.8030542247737082,9.075713250077177,1.0472812838466422e-10,0.3914813112620696,225.72165579985014,10.170692071350043,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G31 310,Qcells North America,Multi-c-Si,0,310.0,283.8,1.994,1.994,1.0,72.0,8.99,45.29,8.39,36.96,0.004495000000000001,-0.140399,44.8,1.8118541237081096,9.003646701182104,1.2270370670438418e-10,0.3449477853847721,227.24031806289506,8.030818800372677,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5 315,Qcells North America,Mono-c-Si,0,315.0,292.2,1.62,,,120.0,9.89,40.29,9.41,33.46,0.0037582,-0.1116033,45.57,1.5017588088898048,9.892028638212091,2.199077452107781e-11,0.23346771098089836,1138.199872055599,4.610192950418856,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5/SC 315,Qcells North America,Mono-c-Si,0,315.0,292.2,1.62,,,60.0,9.89,40.29,9.41,33.46,0.0037582,-0.1116033,45.57,1.5017588088898048,9.892028638212091,2.199077452107781e-11,0.23346771098089836,1138.199872055599,4.610192950418856,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5 315,Qcells North America,Mono-c-Si,0,315.0,291.2,1.63,,,120.0,10.04,39.87,9.55,32.98,0.004016,-0.11243339999999999,45.48,1.513447611858157,10.040005341285447,3.637072483129182e-11,0.2364295000613116,444427.3974742234,6.8364117403312346,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G7 315,Qcells North America,Mono-c-Si,0,315.0,292.2,1.63,,,60.0,9.99,39.84,9.51,33.14,0.0037962,-0.10836480000000001,45.85,1.4762231153220204,9.991933807437581,1.8945419796704696e-11,0.22431867033237018,1158.8245816470262,5.1807351502999355,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK-G41 315,Qcells North America,Mono-c-Si,0,315.0,291.9,1.61,,,60.0,9.98,40.62,9.53,33.04,0.004491,-0.11373600000000002,44.89,1.5420919719265427,9.980002933270558,3.6261590452488145e-11,0.2938940217852456,999999.5078588155,7.565737637123778,-0.379,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPRO L G2 315,Qcells North America,Multi-c-Si,0,315.0,288.5,1.912936,1.948,0.982,72.0,9.12,45.61,8.52,36.97,0.0036479999999999998,-0.145952,43.6,1.86029702752591,9.13261578381193,2.015916468982633e-10,0.36632483829514556,264.81769529989396,8.885285851006085,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L G4 315,Qcells North America,Multi-c-Si,0,315.0,288.0,1.994,1.994,1.0,72.0,9.06,45.53,8.46,36.96,0.003624,-0.14114300000000002,45.1,1.7987137466704497,9.074563705431384,9.021985192538843e-11,0.37546719651317184,233.57605883376695,5.444494318490886,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L G41 315,Qcells North America,Multi-c-Si,0,315.0,288.0,1.994,1.994,1.0,72.0,9.06,45.53,8.46,36.96,0.003624,-0.14114300000000002,45.1,1.7987137466704497,9.074563705431384,9.021985192538843e-11,0.37546719651317184,233.57605883376695,5.444494318490886,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G23 315,Qcells North America,Multi-c-Si,0,315.0,285.3,1.912936,1.948,0.982,72.0,9.06,45.53,8.46,37.24,0.00453,-0.14114300000000002,46.9,1.8421990632721292,9.072470512886593,1.6401167504986633e-10,0.3277537698792753,238.1176571000681,10.513351183081214,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G3 315,Qcells North America,Multi-c-Si,0,315.0,286.1,1.972,1.972,1.0,72.0,9.12,45.61,8.52,36.97,0.00456,-0.13683,46.6,1.81366770747508,9.134023930876896,1.0718524514800627e-10,0.3778169828070116,245.7008040968222,10.312748008086814,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G31 315,Qcells North America,Multi-c-Si,0,315.0,288.4,1.994,1.994,1.0,72.0,9.06,45.53,8.46,37.24,0.00453,-0.14114300000000002,44.8,1.8232261057170467,9.072999216027545,1.2674968367376108e-10,0.3325069311107601,231.7457353897897,8.24471107208532,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PLUS L-G42 317,Qcells North America,Multi-c-Si,0,317.0,293.1,1.994,1.994,1.0,72.0,9.36,46.0,8.76,36.2,0.0037440000000000004,-0.1334,43.2,1.7608882751478974,9.376116109109986,4.1670928852305826e-11,0.5255533773215798,305.2337120105797,5.66289253931086,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5 320,Qcells North America,Mono-c-Si,0,320.0,297.0,1.62,,,120.0,9.94,40.56,9.47,33.8,0.0037772,-0.11235120000000001,45.57,1.5135051139854243,9.941229911967834,2.279846596324336e-11,0.21989121167590805,1777.1342996837193,4.868382834890802,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G5/SC 320,Qcells North America,Mono-c-Si,0,320.0,297.0,1.62,,,60.0,9.94,40.56,9.47,33.8,0.0037772,-0.11235120000000001,45.57,1.5135051139854243,9.941229911967834,2.279846596324336e-11,0.21989121167590805,1777.1342996837193,4.868382834890802,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 320,Qcells North America,Mono-c-Si,0,320.0,298.9,1.734,,,60.0,10.3,39.65,9.8,32.64,0.0045320000000000004,-0.10665850000000002,44.36,1.4486188650315746,10.302435635985535,1.3316324074961962e-11,0.2595712589629675,1097.6944259051222,3.0283341338596923,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5 320,Qcells North America,Mono-c-Si,0,320.0,295.9,1.63,,,120.0,10.09,40.13,9.6,33.32,0.0040360000000000005,-0.1131666,45.48,1.5259879496295565,10.090004933279017,3.827665490427568e-11,0.22181308003661857,453684.4315220225,7.23444236689184,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5/SC 320,Qcells North America,Mono-c-Si,0,320.0,296.0,1.62,,,60.0,10.09,40.13,9.6,33.32,0.0040360000000000005,-0.1131666,45.48,1.5259879496295565,10.090004933279017,3.827665490427568e-11,0.22181308003661857,453684.4315220225,7.23444236689184,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G7 320,Qcells North America,Mono-c-Si,0,320.0,296.9,1.63,,,60.0,10.04,40.1,9.56,33.47,0.0038151999999999995,-0.10907200000000002,45.85,1.4882299837698267,10.041837772003747,1.9876757193967878e-11,0.21101398505964422,1152.7982977083393,5.547407167333268,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G4 320,Qcells North America,Multi-c-Si,0,320.0,292.7,1.994,1.994,1.0,72.0,9.39,46.17,8.76,36.39,0.0037560000000000007,-0.143127,45.1,1.7953828225921147,9.409246770736257,6.261189997182167e-11,0.5131448595843798,250.35007231069906,2.087501989798211,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G41 320,Qcells North America,Multi-c-Si,0,320.0,292.7,1.994,1.994,1.0,72.0,9.39,46.17,8.76,36.39,0.0037560000000000007,-0.143127,45.1,1.7953828225921147,9.409246770736257,6.261189997182167e-11,0.5131448595843798,250.35007231069906,2.087501989798211,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 320,Qcells North America,Multi-c-Si,0,320.0,295.9,1.994,1.994,1.0,72.0,9.39,46.17,8.79,36.39,0.0037560000000000007,-0.13389299999999998,43.2,1.7686794092604086,9.405834906540733,4.260744137617335e-11,0.5182833272347015,307.33876594997474,5.824861929225553,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L G4 320,Qcells North America,Multi-c-Si,0,320.0,292.7,1.994,1.994,1.0,72.0,9.13,45.76,8.53,37.53,0.0036520000000000003,-0.141856,45.1,1.817574998030047,9.142768397799422,1.0412614934501701e-10,0.32198722789803724,230.23589441224186,6.6033752514436985,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L G41 320,Qcells North America,Multi-c-Si,0,320.0,292.7,1.994,1.994,1.0,72.0,9.13,45.76,8.53,37.53,0.0036520000000000003,-0.141856,45.1,1.817574998030047,9.142768397799422,1.0412614934501701e-10,0.32198722789803724,230.23589441224186,6.6033752514436985,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPRO L-G31 320,Qcells North America,Multi-c-Si,0,320.0,293.1,1.994,1.994,1.0,72.0,9.13,45.76,8.53,37.53,0.0045650000000000005,-0.141856,44.8,1.8346888389099887,9.14229960055526,1.317520782175542e-10,0.31771054624071704,235.8367160710192,8.51452645705277,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PLUS L-G41 322,Qcells North America,Multi-c-Si,0,323.0,298.7,1.994,1.994,1.0,72.0,9.16,45.9,8.56,37.7,0.003664,-0.13311,43.2,1.7993792885983535,9.173108877935647,7.488228314855051e-11,0.3206768825998068,224.07717335506237,10.98752884112515,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PRO L-G41 322,Qcells North America,Multi-c-Si,0,323.0,298.7,1.994,1.994,1.0,72.0,9.16,45.9,8.56,37.7,0.003664,-0.13311,43.2,1.7993792885983535,9.173108877935647,7.488228314855051e-11,0.3206768825998068,224.07717335506237,10.98752884112515,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PLUS L-G42 325,Qcells North America,Multi-c-Si,0,325.0,300.6,1.994,1.994,1.0,72.0,9.44,46.3,8.85,36.7,0.003776,-0.13426999999999997,43.2,1.7777961918044602,9.453862925887131,4.5565783116874106e-11,0.4893187374653101,333.2030374676078,6.349946440961895,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 325,Qcells North America,Mono-c-Si,0,325.0,303.7,1.734,,,60.0,10.36,39.9,9.86,32.97,0.0045584,-0.10733100000000001,44.36,1.4603087490582651,10.362324483207306,1.4050801263131305e-11,0.2452293813247746,1092.9639993263468,3.429929508476007,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5 325,Qcells North America,Mono-c-Si,0,325.0,303.2,1.636,,,60.0,10.14,40.4,9.66,33.65,0.0044616,-0.108676,44.73,1.4990170312518867,10.141443036206375,1.9966569832119143e-11,0.21854824445773985,1535.7059599932545,6.601924577311837,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5/SC 325,Qcells North America,Mono-c-Si,0,325.0,300.7,1.62,,,60.0,10.14,40.4,9.66,33.65,0.004056000000000001,-0.11392799999999997,45.48,1.540583649822862,10.140629077831774,4.1370202532554506e-11,0.20910548010083715,3370.5363229529517,7.8697373349442765,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G7 325,Qcells North America,Mono-c-Si,0,325.0,301.7,1.63,,,60.0,10.1,40.36,9.61,33.81,0.003838,-0.10977920000000001,45.85,1.5012044762387402,10.102344716255065,2.1199456757987033e-11,0.19634970143943595,845.7876424807357,6.052360102100504,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G4 325,Qcells North America,Multi-c-Si,0,325.0,297.4,1.994,1.994,1.0,72.0,9.44,46.43,8.85,36.7,0.003776,-0.143933,45.1,1.8040093507923345,9.452994100666302,6.196600245088515e-11,0.4987058003857846,362.3015774951881,1.941910209714092,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G41 325,Qcells North America,Multi-c-Si,0,325.0,297.4,1.994,1.994,1.0,72.0,9.44,46.43,8.85,36.7,0.003776,-0.143933,45.1,1.8040093507923345,9.452994100666302,6.196600245088515e-11,0.4987058003857846,362.3015774951881,1.941910209714092,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 325,Qcells North America,Multi-c-Si,0,325.0,300.6,1.994,1.994,1.0,72.0,9.44,46.43,8.85,36.7,0.003776,-0.134647,43.2,1.7801109428120792,9.453929878540354,4.383065047303034e-11,0.5043174368022071,341.76585189695146,6.016547131540288,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PLUS L-G42 330,Qcells North America,Multi-c-Si,0,330.0,305.4,1.994,1.994,1.0,72.0,9.49,46.55,8.91,37.02,0.003796,-0.13499499999999998,43.2,1.789288838484377,9.50207609675647,4.7150632592157905e-11,0.4732055775047708,371.86859456658993,6.593498395644685,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 330,Qcells North America,Mono-c-Si,0,330.0,308.5,1.734,,,60.0,10.41,40.15,9.91,33.29,0.004580399999999999,-0.1080035,44.36,1.4718033015186796,10.412235860726831,1.4746016215568594e-11,0.23244783021322488,1082.259696694949,3.795922666228607,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/HL 330,Qcells North America,Mono-c-Si,0,330.0,308.5,1.73,,,60.0,10.41,40.15,9.91,33.29,0.004580399999999999,-0.1080035,44.36,1.4718033015186796,10.412235860726831,1.4746016215568594e-11,0.23244783021322488,1082.259696694949,3.795922666228607,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/SC 330,Qcells North America,Mono-c-Si,0,330.0,308.5,1.73,,,60.0,10.41,40.15,9.91,33.29,0.004580399999999999,-0.1080035,44.36,1.4718033015186796,10.412235860726831,1.4746016215568594e-11,0.23244783021322488,1082.259696694949,3.795922666228607,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/TS 330,Qcells North America,Mono-c-Si,0,330.0,308.5,1.73,,,60.0,10.41,40.15,9.91,33.29,0.004580399999999999,-0.1080035,44.36,1.4718033015186796,10.412235860726831,1.4746016215568594e-11,0.23244783021322488,1082.259696694949,3.795922666228607,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 330,Qcells North America,Mono-c-Si,0,330.0,305.7,1.73,,,60.0,10.41,39.96,10.01,33.61,0.0040599,-0.10869120000000002,46.71,1.4725530627560413,10.41000161278154,1.7068607882600527e-11,0.15491974510950696,999979.5214565706,3.9236333187678274,-0.345,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 330,Qcells North America,Mono-c-Si,0,330.0,305.7,1.73,,,60.0,10.41,39.96,10.01,33.61,0.0040599,-0.10869120000000002,46.71,1.4725530627560413,10.41000161278154,1.7068607882600527e-11,0.15491974510950696,999979.5214565706,3.9236333187678274,-0.345,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO-G5 330,Qcells North America,Mono-c-Si,0,330.0,307.9,1.636,,,60.0,10.2,40.66,9.71,33.98,0.004488,-0.1093754,44.73,1.5117388305397104,10.202011218151885,2.1191251403153567e-11,0.20518240638948326,1040.5933418221073,7.070432769900142,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6 330,Qcells North America,Mono-c-Si,0,330.0,305.6,1.738,,,60.0,10.57,39.74,10.06,32.81,0.0044394000000000005,-0.10849020000000002,45.7,1.486635555766396,10.571492432576356,2.5930603243575516e-11,0.23542079484478645,1667.3437038864781,6.940670351344401,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G7 330,Qcells North America,Mono-c-Si,0,330.0,306.5,1.63,,,60.0,10.15,40.62,9.67,34.14,0.003857,-0.11048640000000001,45.85,1.5124142963706346,10.151610065279641,2.1921499053994195e-11,0.18347752653477115,1156.6592848355353,6.292941610908275,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 330,Qcells North America,Mono-c-Si,0,330.0,308.4,1.732,,,60.0,10.52,39.71,10.01,32.97,0.0045236,-0.107217,44.4,1.4557332973404729,10.522684051285353,1.4907605230169963e-11,0.22260926467147424,872.5055027130156,3.4285132682775776,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 330,Qcells North America,Mono-c-Si,0,330.0,308.4,1.732,,,60.0,10.52,39.71,10.01,32.97,0.0045236,-0.107217,44.4,1.4557332973404729,10.522684051285353,1.4907605230169963e-11,0.22260926467147424,872.5055027130156,3.4285132682775776,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G4 330,Qcells North America,Multi-c-Si,0,330.0,302.1,1.994,1.994,1.0,72.0,9.49,46.68,8.91,37.02,0.003796,-0.144708,45.1,1.8157054130547534,9.50121989603458,6.415566363908367e-11,0.4824603027614211,408.0740640402295,2.179650766483321,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G41 330,Qcells North America,Multi-c-Si,0,330.0,302.1,1.994,1.994,1.0,72.0,9.49,46.68,8.91,37.02,0.003796,-0.144708,45.1,1.8157054130547534,9.50121989603458,6.415566363908367e-11,0.4824603027614211,408.0740640402295,2.179650766483321,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 330,Qcells North America,Multi-c-Si,0,330.0,305.4,1.994,1.994,1.0,72.0,9.49,46.68,8.91,37.02,0.003796,-0.135372,43.2,1.7916107927077516,9.502114446941409,4.536940158041632e-11,0.48809344497065343,382.35397932087363,6.262084833120436,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PLUS L-G42 332,Qcells North America,Multi-c-Si,0,332.0,307.3,1.994,1.994,1.0,72.0,9.51,46.8,8.94,37.2,0.003804,-0.13571999999999998,43.2,1.7973304081179189,9.520606127404946,4.626120894413284e-11,0.477078550072015,427.77321682243723,6.406804867808781,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America BLINE PLUS L-G42 335,Qcells North America,Multi-c-Si,0,335.0,310.1,1.994,1.994,1.0,72.0,9.54,46.81,8.97,37.33,0.003816,-0.135749,43.2,1.8006884095208922,9.550394163768692,4.843907579490935e-11,0.4597614202527099,421.97951272536653,6.775395382516896,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 335,Qcells North America,Mono-c-Si,0,335.0,313.3,1.734,,,60.0,10.47,40.41,9.97,33.62,0.0046068,-0.10870289999999999,44.36,1.4799656394985943,10.470005034525961,1.4510016714506168e-11,0.22020480857602254,457897.99302716204,3.5993475578915874,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/HL 335,Qcells North America,Mono-c-Si,0,335.0,313.3,1.73,,,60.0,10.47,40.41,9.97,33.62,0.0046068,-0.10870289999999999,44.36,1.4799656394985943,10.470005034525961,1.4510016714506168e-11,0.22020480857602254,457897.99302716204,3.5993475578915874,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/SC 335,Qcells North America,Mono-c-Si,0,335.0,313.3,1.73,,,60.0,10.47,40.41,9.97,33.62,0.0046068,-0.10870289999999999,44.36,1.4799656394985943,10.470005034525961,1.4510016714506168e-11,0.22020480857602254,457897.99302716204,3.5993475578915874,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/TS 335,Qcells North America,Mono-c-Si,0,335.0,313.3,1.73,,,60.0,10.47,40.41,9.97,33.62,0.0046068,-0.10870289999999999,44.36,1.4799656394985943,10.470005034525961,1.4510016714506168e-11,0.22020480857602254,457897.99302716204,3.5993475578915874,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 335,Qcells North America,Mono-c-Si,0,335.0,310.5,1.73,,,60.0,10.57,39.96,10.01,33.61,0.0041223,-0.10869120000000002,46.71,1.4754507576893905,10.575533732907862,1.8080895137581665e-11,0.1736129622493272,331.61864808620936,4.3222378961919015,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 335,Qcells North America,Mono-c-Si,0,335.0,310.5,1.73,,,60.0,10.47,39.96,10.01,33.61,0.004083300000000001,-0.10869120000000002,46.71,1.4689316962857057,10.470002765277439,1.605606185923301e-11,0.17633017879981858,667637.8592758822,3.3617985182635253,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G5 335,Qcells North America,Mono-c-Si,0,335.0,312.7,1.636,,,60.0,10.25,40.92,9.76,34.31,0.00451,-0.11007480000000001,44.73,1.5237506849657063,10.25189689413477,2.2194563421290344e-11,0.19225412230749375,1038.8586154276593,7.429766841731749,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 335,Qcells North America,Mono-c-Si,0,335.0,313.2,1.732,,,60.0,10.57,39.96,10.06,33.29,0.0045451,-0.10789200000000002,44.4,1.4672166389001622,10.572559918277554,1.5637560288958335e-11,0.21014077967080835,867.6792961274704,3.7907820916087083,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 335,Qcells North America,Mono-c-Si,0,335.0,313.2,1.732,,,60.0,10.57,39.96,10.06,33.29,0.0045451,-0.10789200000000002,44.4,1.4672166389001622,10.572559918277554,1.5637560288958335e-11,0.21014077967080835,867.6792961274704,3.7907820916087083,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G4 335,Qcells North America,Multi-c-Si,0,335.0,306.8,1.994,1.994,1.0,72.0,9.54,46.94,8.97,37.33,0.003816,-0.145514,45.1,1.8272965558900582,9.549542711642133,6.594036404930832e-11,0.46889173528158956,468.75852841233933,2.3578993151701244,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G41 335,Qcells North America,Multi-c-Si,0,335.0,306.8,1.994,1.994,1.0,72.0,9.54,46.94,8.97,37.33,0.003816,-0.145514,45.1,1.8272965558900582,9.549542711642133,6.594036404930832e-11,0.46889173528158956,468.75852841233933,2.3578993151701244,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 335,Qcells North America,Multi-c-Si,0,335.0,307.5,1.994,1.994,1.0,72.0,9.54,46.81,8.97,37.33,0.00477,-0.1376214,45.22,1.8142959336854207,9.549923565117128,5.889065164479699e-11,0.4565844202913368,438.9365468613844,6.856696435231955,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42/TAA 335,Qcells North America,Multi-c-Si,0,335.0,307.5,1.994,1.994,1.0,72.0,9.54,46.81,8.97,37.33,0.00477,-0.1376214,45.22,1.8142959336854207,9.549923565117128,5.889065164479699e-11,0.4565844202913368,438.9365468613844,6.856696435231955,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 340,Qcells North America,Mono-c-Si,0,340.0,318.1,1.734,,,60.0,10.52,40.66,10.02,33.94,0.0046288,-0.1093754,44.36,1.4951459684330122,10.522010683357024,1.6220017490917835e-11,0.2069579524522299,1082.8148048154032,4.51256322805753,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/AC 340,Qcells North America,Mono-c-Si,0,340.0,318.0,1.73,,,60.0,10.52,40.66,10.02,33.94,0.0046288,-0.1093754,44.4,1.4951459684330122,10.522010683357024,1.6220017490917835e-11,0.2069579524522299,1082.8148048154032,4.51256322805753,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/HL 340,Qcells North America,Mono-c-Si,0,340.0,318.1,1.73,,,60.0,10.52,40.66,10.02,33.94,0.0046288,-0.1093754,44.36,1.4951459684330122,10.522010683357024,1.6220017490917835e-11,0.2069579524522299,1082.8148048154032,4.51256322805753,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/SC 340,Qcells North America,Mono-c-Si,0,340.0,318.1,1.73,,,60.0,10.52,40.66,10.02,33.94,0.0046288,-0.1093754,44.36,1.4951459684330122,10.522010683357024,1.6220017490917835e-11,0.2069579524522299,1082.8148048154032,4.51256322805753,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/TS 340,Qcells North America,Mono-c-Si,0,340.0,318.1,1.73,,,60.0,10.52,40.66,10.02,33.94,0.0046288,-0.1093754,44.36,1.4951459684330122,10.522010683357024,1.6220017490917835e-11,0.2069579524522299,1082.8148048154032,4.51256322805753,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 340,Qcells North America,Mono-c-Si,0,340.0,315.3,1.73,,,60.0,10.63,40.2,10.12,33.61,0.0041457,-0.10934400000000001,46.71,1.471403886526725,10.63000484388986,1.4495617706811946e-11,0.19809322893989367,433323.9804023017,2.382515967421536,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 340,Qcells North America,Mono-c-Si,0,340.0,315.3,1.73,,,60.0,10.63,40.2,10.12,33.61,0.0041457,-0.10934400000000001,46.71,1.471403886526725,10.63000484388986,1.4495617706811946e-11,0.19809322893989367,433323.9804023017,2.382515967421536,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6 340,Qcells North America,Mono-c-Si,0,340.0,315.1,1.738,,,60.0,10.68,40.24,10.16,33.45,0.0044856,-0.10985520000000001,45.7,1.5109041745141403,10.682100743251945,2.8875673348949422e-11,0.2101502476918301,1068.3860320917274,7.789059043583327,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+ 340,Qcells North America,Mono-c-Si,0,340.0,316.0,1.73,,,60.0,10.68,40.24,10.16,33.45,0.0050196,-0.11106240000000002,45.15,1.5124607552966784,10.682065689443476,2.9679591015503934e-11,0.209814293291486,1084.779112315181,6.782224407367915,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+/SC 340,Qcells North America,Mono-c-Si,0,340.0,316.0,1.73,,,60.0,10.68,40.24,10.16,33.45,0.0050196,-0.11106240000000002,45.15,1.5124607552966784,10.682065689443476,2.9679591015503934e-11,0.209814293291486,1084.779112315181,6.782224407367915,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 340,Qcells North America,Mono-c-Si,0,340.0,318.0,1.732,,,60.0,10.63,40.2,10.12,33.61,0.0045709,-0.10854000000000001,44.4,1.4784771671433798,10.63240226339282,1.6451769551624787e-11,0.1966245548044087,870.0624037004308,4.171253904326235,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 340,Qcells North America,Mono-c-Si,0,340.0,318.0,1.732,,,60.0,10.63,40.2,10.12,33.61,0.0045709,-0.10854000000000001,44.4,1.4784771671433798,10.63240226339282,1.6451769551624787e-11,0.1966245548044087,870.0624037004308,4.171253904326235,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 340,Qcells North America,Multi-c-Si,0,340.0,312.2,1.994,1.994,1.0,72.0,9.59,47.07,9.03,37.63,0.004795000000000001,-0.1383858,45.22,1.82552813247799,9.59834772729174,6.025861873389883e-11,0.44461482937256946,510.7805216960897,7.0051183036477465,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42/TAA 340,Qcells North America,Multi-c-Si,0,340.0,312.2,1.994,1.994,1.0,72.0,9.59,47.07,9.03,37.63,0.004795000000000001,-0.1383858,45.22,1.82552813247799,9.59834772729174,6.025861873389883e-11,0.44461482937256946,510.7805216960897,7.0051183036477465,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 345,Qcells North America,Mono-c-Si,0,345.0,322.8,1.734,,,60.0,10.58,40.92,10.07,34.25,0.0046552,-0.11007480000000001,44.36,1.507265915015211,10.582526313953911,1.706483812867167e-11,0.19645379167822494,822.7327226871396,4.899604286160614,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/AC 345,Qcells North America,Mono-c-Si,0,345.0,322.8,1.73,,,60.0,10.58,40.92,10.07,34.25,0.0046552,-0.11007480000000001,44.4,1.507265915015211,10.582526313953911,1.706483812867167e-11,0.19645379167822494,822.7327226871396,4.899604286160614,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/HL 345,Qcells North America,Mono-c-Si,0,345.0,322.9,1.73,,,60.0,10.58,40.92,10.07,34.25,0.0046552,-0.11007480000000001,44.36,1.507265915015211,10.582526313953911,1.706483812867167e-11,0.19645379167822494,822.7327226871396,4.899604286160614,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/SC 345,Qcells North America,Mono-c-Si,0,345.0,322.9,1.73,,,60.0,10.58,40.92,10.07,34.25,0.0046552,-0.11007480000000001,44.36,1.507265915015211,10.582526313953911,1.706483812867167e-11,0.19645379167822494,822.7327226871396,4.899604286160614,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/TS 345,Qcells North America,Mono-c-Si,0,345.0,322.9,1.73,,,60.0,10.58,40.92,10.07,34.25,0.0046552,-0.11007480000000001,44.36,1.507265915015211,10.582526313953911,1.706483812867167e-11,0.19645379167822494,822.7327226871396,4.899604286160614,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 345,Qcells North America,Mono-c-Si,0,345.0,320.0,1.73,,,60.0,10.68,40.45,10.17,33.92,0.0041652,-0.11002400000000001,46.71,1.4825828270483463,10.68000420253215,1.5118499552280162e-11,0.1870416203906737,475338.4141655301,2.6933839692121415,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 345,Qcells North America,Mono-c-Si,0,345.0,320.0,1.73,,,60.0,10.68,40.45,10.17,33.92,0.0041652,-0.11002400000000001,46.71,1.4825828270483463,10.68000420253215,1.5118499552280162e-11,0.1870416203906737,475338.4141655301,2.6933839692121415,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6 345,Qcells North America,Mono-c-Si,0,345.0,320.8,1.73,,,60.0,10.73,40.49,10.22,33.76,0.0050431,-0.11175240000000002,45.15,1.523320847786056,10.731282947310627,3.0625252102603827e-11,0.19872111681709326,1662.0150354110942,7.008861551486524,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+ 345,Qcells North America,Mono-c-Si,0,345.0,320.8,1.73,,,60.0,10.73,40.49,10.22,33.76,0.0050431,-0.11175240000000002,45.15,1.523320847786056,10.731282947310627,3.0625252102603827e-11,0.19872111681709326,1662.0150354110942,7.008861551486524,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+/SC 345,Qcells North America,Mono-c-Si,0,345.0,320.8,1.73,,,60.0,10.73,40.49,10.22,33.76,0.0050431,-0.11175240000000002,45.15,1.523320847786056,10.731282947310627,3.0625252102603827e-11,0.19872111681709326,1662.0150354110942,7.008861551486524,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6P+ 345,Qcells North America,Mono-c-Si,0,345.0,320.8,1.73,,,60.0,10.73,40.49,10.22,33.76,0.0050431,-0.11175240000000002,45.15,1.523320847786056,10.731282947310627,3.0625252102603827e-11,0.19872111681709326,1662.0150354110942,7.008861551486524,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 345,Qcells North America,Mono-c-Si,0,345.0,322.8,1.732,,,60.0,10.68,40.45,10.17,33.92,0.0045924,-0.10921500000000002,44.4,1.4851014180714424,10.680004182883415,1.5834471630961727e-11,0.18649091747772117,476165.38364864566,3.7936701632935836,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 345,Qcells North America,Mono-c-Si,0,345.0,322.8,1.732,,,60.0,10.68,40.45,10.17,33.92,0.0045924,-0.10921500000000002,44.4,1.4851014180714424,10.680004182883415,1.5834471630961727e-11,0.18649091747772117,476165.38364864566,3.7936701632935836,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G41 345,Qcells North America,Mono-c-Si,0,345.0,316.8,1.994,,,72.0,9.6,46.86,9.03,38.22,0.003648,-0.1354254,45.51,1.8085549617187746,9.60968775684284,5.295781310842744e-11,0.35125106653701493,348.0692525833534,7.900201903524719,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 345,Qcells North America,Multi-c-Si,0,345.0,316.9,1.994,1.994,1.0,72.0,9.64,47.32,9.09,37.93,0.004820000000000001,-0.1391208,45.22,1.8365713226503926,9.646856085849356,6.181438615652315e-11,0.43169088247002424,606.9790408446248,7.175909913372669,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42/TAA 345,Qcells North America,Multi-c-Si,0,345.0,316.9,1.994,1.994,1.0,72.0,9.64,47.46,9.09,37.93,0.004820000000000001,-0.1395324,45.22,1.83908181382583,9.64677762105983,5.93544798940372e-11,0.4473908680513706,636.3365974986099,6.824240089584844,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10a+ 350,Qcells North America,Mono-c-Si,0,350.0,324.0,1.66,,,60.0,10.97,41.11,10.37,33.76,0.005452090000000001,-0.11831458,45.9,1.5748864035724413,10.976471389902086,5.0114788009225946e-11,0.24689661163525078,418.5276681307218,6.553745509349405,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+ 350,Qcells North America,Mono-c-Si,0,350.0,324.0,1.66,,,60.0,10.97,41.11,10.37,33.76,0.005452090000000001,-0.11831458,45.9,1.5748864035724413,10.976471389902086,5.0114788009225946e-11,0.24689661163525078,418.5276681307218,6.553745509349405,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/HL 350,Qcells North America,Mono-c-Si,0,350.0,324.0,1.66,,,60.0,10.97,41.11,10.37,33.76,0.005452090000000001,-0.11831458,45.9,1.5748864035724413,10.976471389902086,5.0114788009225946e-11,0.24689661163525078,418.5276681307218,6.553745509349405,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+ 350,Qcells North America,Mono-c-Si,0,350.0,327.6,1.734,,,60.0,10.63,41.17,10.13,34.56,0.0046772,-0.1107473,44.36,1.5178052863665858,10.63176722373002,1.757888647212317e-11,0.18544278927035007,1115.4540699150277,5.107860751575253,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/HL 350,Qcells North America,Mono-c-Si,0,350.0,327.7,1.73,,,60.0,10.63,41.17,10.13,34.56,0.0046772,-0.1107473,44.36,1.5178052863665858,10.63176722373002,1.757888647212317e-11,0.18544278927035007,1115.4540699150277,5.107860751575253,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/SC 350,Qcells North America,Mono-c-Si,0,350.0,327.7,1.73,,,60.0,10.63,41.17,10.13,34.56,0.0046772,-0.1107473,44.36,1.5178052863665858,10.63176722373002,1.757888647212317e-11,0.18544278927035007,1115.4540699150277,5.107860751575253,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G6+/TS 350,Qcells North America,Mono-c-Si,0,350.0,327.7,1.73,,,60.0,10.63,41.17,10.13,34.56,0.0046772,-0.1107473,44.36,1.5178052863665858,10.63176722373002,1.757888647212317e-11,0.18544278927035007,1115.4540699150277,5.107860751575253,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 350,Qcells North America,Mono-c-Si,0,350.0,324.8,1.73,,,60.0,10.74,40.7,10.22,34.24,0.004188600000000001,-0.11070400000000001,46.71,1.4994471542039687,10.74274121132852,1.739761297754299e-11,0.1737465617096979,680.7348571045558,3.8418537879387658,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 350,Qcells North America,Mono-c-Si,0,350.0,324.8,1.73,,,60.0,10.74,40.7,10.22,34.24,0.004188600000000001,-0.11070400000000001,46.71,1.4994471542039687,10.74274121132852,1.739761297754299e-11,0.1737465617096979,680.7348571045558,3.8418537879387658,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6 350,Qcells North America,Mono-c-Si,0,350.0,325.6,1.73,,,60.0,10.79,40.73,10.27,34.07,0.0050713,-0.11241480000000001,45.15,1.5353976257755917,10.791836486316065,3.24282129871941e-11,0.18641083293530622,1095.2289517585289,7.460720876487813,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+ 350,Qcells North America,Mono-c-Si,0,350.0,325.6,1.73,,,60.0,10.79,40.73,10.27,34.07,0.0050713,-0.11241480000000001,45.15,1.5353976257755917,10.791836486316065,3.24282129871941e-11,0.18641083293530622,1095.2289517585289,7.460720876487813,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+/SC 350,Qcells North America,Mono-c-Si,0,350.0,325.6,1.73,,,60.0,10.79,40.73,10.27,34.07,0.0050713,-0.11241480000000001,45.15,1.5353976257755917,10.791836486316065,3.24282129871941e-11,0.18641083293530622,1095.2289517585289,7.460720876487813,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6P+ 350,Qcells North America,Mono-c-Si,0,350.0,325.6,1.73,,,60.0,10.79,40.73,10.27,34.07,0.0050713,-0.11241480000000001,45.15,1.5353976257755917,10.791836486316065,3.24282129871941e-11,0.18641083293530622,1095.2289517585289,7.460720876487813,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 350,Qcells North America,Mono-c-Si,0,350.0,327.6,1.732,,,60.0,10.74,40.7,10.22,34.24,0.0046182,-0.10989000000000002,44.4,1.5018667429509094,10.742694130776968,1.8176641402653148e-11,0.17321808485996476,690.5241118886628,4.933519531966572,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 350,Qcells North America,Mono-c-Si,0,350.0,327.6,1.732,,,60.0,10.74,40.7,10.22,34.24,0.0046182,-0.10989000000000002,44.4,1.5018667429509094,10.742694130776968,1.8176641402653148e-11,0.17321808485996476,690.5241118886628,4.933519531966572,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G41 350,Qcells North America,Mono-c-Si,0,350.0,321.5,1.994,,,72.0,9.65,47.14,9.1,38.44,0.003667,-0.1362346,45.51,1.8168826575464427,9.657539572515061,5.153950764561478e-11,0.35267935115548654,451.39904901412257,7.60894671939164,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42 350,Qcells North America,Multi-c-Si,0,350.0,321.6,1.994,,,72.0,9.64,46.82,9.16,38.2,0.004820000000000001,-0.1376508,45.22,1.827628670178134,9.64024326929684,7.21475300652846e-11,0.3413960664141076,13528.47362887176,8.496272941217496,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS L-G42/TAA 350,Qcells North America,Multi-c-Si,0,350.0,321.6,1.994,1.994,1.0,72.0,9.69,47.71,9.15,38.23,0.004845,-0.1402674,45.22,1.8501220103342255,9.695334377162384,6.088115471184229e-11,0.434534672769145,789.3406935004726,6.994195035371226,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 355,Qcells North America,Mono-c-Si,0,355.0,328.2,1.82,,,66.0,10.49,44.81,9.85,36.03,0.0081822,-0.13617759000000002,46.3,1.7321653864172597,10.502817744591237,6.027654206772772e-11,0.3654620299541463,299.092937914312,2.407876286566383,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 355,Qcells North America,Mono-c-Si,0,355.0,328.2,1.82,,,66.0,10.49,44.81,9.85,36.03,0.0081822,-0.13617759000000002,46.3,1.7321653864172597,10.502817744591237,6.027654206772772e-11,0.3654620299541463,299.092937914312,2.407876286566383,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10a+ 355,Qcells North America,Mono-c-Si,0,355.0,328.7,1.66,,,60.0,11.0,41.14,10.43,34.03,0.0054670000000000005,-0.11840091999999999,45.9,1.579684021127516,11.003802096899099,5.3526087549738585e-11,0.2193099044114713,634.4943684974902,7.0883420368138,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+ 355,Qcells North America,Mono-c-Si,0,355.0,328.7,1.66,,,60.0,11.0,41.14,10.43,34.03,0.0054670000000000005,-0.11840091999999999,45.9,1.579684021127516,11.003802096899099,5.3526087549738585e-11,0.2193099044114713,634.4943684974902,7.0883420368138,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/HL 355,Qcells North America,Mono-c-Si,0,355.0,328.7,1.66,,,60.0,11.0,41.14,10.43,34.03,0.0054670000000000005,-0.11840091999999999,45.9,1.579684021127516,11.003802096899099,5.3526087549738585e-11,0.2193099044114713,634.4943684974902,7.0883420368138,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 355,Qcells North America,Mono-c-Si,0,355.0,329.6,1.73,,,60.0,10.79,40.95,10.28,34.55,0.0042081,-0.11138400000000001,46.71,1.5099644013016602,10.792018770434321,1.7914661943643266e-11,0.16304046723616608,871.4248267214405,4.045035051190869,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 355,Qcells North America,Mono-c-Si,0,355.0,329.6,1.73,,,60.0,10.79,40.95,10.28,34.55,0.0042081,-0.11138400000000001,46.71,1.5099644013016602,10.792018770434321,1.7914661943643266e-11,0.16304046723616608,871.4248267214405,4.045035051190869,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9 355,Qcells North America,Mono-c-Si,0,355.0,327.5,1.82,,,66.0,10.49,44.81,9.85,36.03,0.00846543,-0.13949353000000003,46.3,1.7556520534460838,10.501947031697513,8.526187256345862e-11,0.3604394219087343,316.48110068436665,2.7620203812360304,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 355,Qcells North America,Mono-c-Si,0,355.0,327.5,1.82,,,66.0,10.49,44.81,9.85,36.03,0.00846543,-0.13949353000000003,46.3,1.7556520534460838,10.501947031697513,8.526187256345862e-11,0.3604394219087343,316.48110068436665,2.7620203812360304,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6 355,Qcells North America,Mono-c-Si,0,355.0,330.4,1.73,,,60.0,10.84,40.98,10.33,34.38,0.0050948,-0.1131048,45.15,1.5437049360675201,10.840006917385924,3.2063782964327607e-11,0.17608521111956055,274700.4694897789,7.310299977481908,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+ 355,Qcells North America,Mono-c-Si,0,355.0,330.4,1.73,,,60.0,10.84,40.98,10.33,34.38,0.0050948,-0.1131048,45.15,1.5437049360675201,10.840006917385924,3.2063782964327607e-11,0.17608521111956055,274700.4694897789,7.310299977481908,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6+/SC 355,Qcells North America,Mono-c-Si,0,355.0,330.4,1.73,,,60.0,10.84,40.98,10.33,34.38,0.0050948,-0.1131048,45.15,1.5437049360675201,10.840006917385924,3.2063782964327607e-11,0.17608521111956055,274700.4694897789,7.310299977481908,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6P+ 355,Qcells North America,Mono-c-Si,0,355.0,330.4,1.73,,,60.0,10.84,40.98,10.33,34.38,0.0050948,-0.1131048,45.15,1.5437049360675201,10.840006917385924,3.2063782964327607e-11,0.17608521111956055,274700.4694897789,7.310299977481908,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 355,Qcells North America,Mono-c-Si,0,355.0,332.4,1.732,,,60.0,10.79,40.95,10.28,34.55,0.004639699999999999,-0.11056500000000001,44.4,1.512401860454795,10.791975952564997,1.8716433293925247e-11,0.16251025082946596,887.4128224801723,5.138823540724765,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 355,Qcells North America,Mono-c-Si,0,355.0,332.4,1.732,,,60.0,10.79,40.95,10.28,34.55,0.004639699999999999,-0.11056500000000001,44.4,1.512401860454795,10.791975952564997,1.8716433293925247e-11,0.16251025082946596,887.4128224801723,5.138823540724765,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G41 355,Qcells North America,Mono-c-Si,0,355.0,326.2,1.994,,,72.0,9.71,47.43,9.18,38.67,0.0036898,-0.1370727,45.51,1.8256091634175708,9.715329285855441,5.023688258655413e-11,0.35355434274321246,644.1787776012287,7.323003001525467,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G52 355,Qcells North America,Multi-c-Si,0,355.0,328.9,1.951,,,72.0,9.82,46.57,9.28,38.24,0.004910000000000001,-0.12760180000000002,45.36,1.7531790706536758,9.826813584665247,2.829367005248736e-11,0.32014272559017315,461.40200538341765,7.865324339120223,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G53 355,Qcells North America,Multi-c-Si,0,355.0,328.9,1.951,,,72.0,9.82,46.57,9.28,38.24,0.004910000000000001,-0.12760180000000002,45.36,1.7531790706536758,9.826813584665247,2.829367005248736e-11,0.32014272559017315,461.40200538341765,7.865324339120223,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 360,Qcells North America,Mono-c-Si,0,360.0,333.0,1.82,,,66.0,10.52,44.85,9.91,36.32,0.0082056,-0.13629915,46.3,1.7377316980478883,10.529029255247579,6.437028948523142e-11,0.33428423411297387,389.47512406837484,2.9229706702610203,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 360,Qcells North America,Mono-c-Si,0,360.0,333.0,1.82,,,66.0,10.52,44.85,9.91,36.32,0.0082056,-0.13629915,46.3,1.7377316980478883,10.529029255247579,6.437028948523142e-11,0.33428423411297387,389.47512406837484,2.9229706702610203,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10a+ 360,Qcells North America,Mono-c-Si,0,360.0,333.5,1.66,,,60.0,11.04,41.18,10.49,34.31,0.00548688,-0.11851604,45.9,1.5855677347930182,11.042273667515968,5.7798764788026265e-11,0.19167720330882446,930.7062089691298,7.716464818038637,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+ 360,Qcells North America,Mono-c-Si,0,360.0,333.5,1.66,,,60.0,11.04,41.18,10.49,34.31,0.00548688,-0.11851604,45.9,1.5855677347930182,11.042273667515968,5.7798764788026265e-11,0.19167720330882446,930.7062089691298,7.716464818038637,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/AC 360,Qcells North America,Mono-c-Si,0,360.0,331.8,1.66,,,60.0,11.04,41.18,10.49,34.31,0.00548688,-0.11851604,47.2,1.5855677347930182,11.042273667515968,5.7798764788026265e-11,0.19167720330882446,930.7062089691298,7.716464818038637,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/HL 360,Qcells North America,Mono-c-Si,0,360.0,333.5,1.66,,,60.0,11.04,41.18,10.49,34.31,0.00548688,-0.11851604,45.9,1.5855677347930182,11.042273667515968,5.7798764788026265e-11,0.19167720330882446,930.7062089691298,7.716464818038637,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8 360,Qcells North America,Mono-c-Si,0,360.0,334.3,1.73,,,60.0,10.84,41.19,10.33,34.85,0.0042276,-0.1120368,46.71,1.5207795229104726,10.841883009959112,1.863992781699704e-11,0.1524646738860708,877.6996047079657,4.3409127427663865,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G8+ 360,Qcells North America,Mono-c-Si,0,360.0,334.3,1.73,,,60.0,10.84,41.19,10.33,34.85,0.0042276,-0.1120368,46.71,1.5207795229104726,10.841883009959112,1.863992781699704e-11,0.1524646738860708,877.6996047079657,4.3409127427663865,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9 360,Qcells North America,Mono-c-Si,0,360.0,332.3,1.82,,,66.0,10.52,44.85,9.91,36.32,0.00848964,-0.13961805000000002,46.3,1.7613455321649234,10.52826422608849,9.104744228019228e-11,0.329240546910715,419.10891000685297,3.2784181715318597,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 360,Qcells North America,Mono-c-Si,0,360.0,332.3,1.82,,,66.0,10.52,44.85,9.91,36.32,0.00848964,-0.13961805000000002,46.3,1.7613455321649234,10.52826422608849,9.104744228019228e-11,0.329240546910715,419.10891000685297,3.2784181715318597,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6 360,Qcells North America,Mono-c-Si,0,360.0,335.2,1.73,,,60.0,10.9,41.23,10.38,34.69,0.005123,-0.11379480000000002,45.15,1.558498638123397,10.901601794758212,3.5219460176257087e-11,0.16449892450726528,1119.393326191304,8.091592228615854,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G6P+ 360,Qcells North America,Mono-c-Si,0,360.0,335.2,1.73,,,60.0,10.9,41.23,10.38,34.69,0.005123,-0.11379480000000002,45.15,1.558498638123397,10.901601794758212,3.5219460176257087e-11,0.16449892450726528,1119.393326191304,8.091592228615854,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8 360,Qcells North America,Mono-c-Si,0,360.0,337.2,1.732,,,60.0,10.84,41.19,10.33,34.85,0.0046612,-0.111213,44.4,1.5232346024558197,10.841842675956052,1.9473107931767955e-11,0.15193218630668479,893.7789640012836,5.437518457280927,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO-G8+ 360,Qcells North America,Mono-c-Si,0,360.0,337.2,1.732,,,60.0,10.84,41.19,10.33,34.85,0.0046612,-0.111213,44.4,1.5232346024558197,10.841842675956052,1.9473107931767955e-11,0.15193218630668479,893.7789640012836,5.437518457280927,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G41 360,Qcells North America,Mono-c-Si,0,360.0,330.9,1.994,,,72.0,9.77,47.71,9.26,38.89,0.0037126,-0.1378819,45.51,1.833929937270811,9.77310591958955,4.896463382882097e-11,0.35456089982813843,1115.3090723368591,7.037756719487966,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G42 360,Qcells North America,Mono-c-Si,0,360.0,331.2,1.927,,,72.0,9.77,47.71,9.26,38.89,0.0037126,-0.1378819,45.51,1.833929937270811,9.77310591958955,4.896463382882097e-11,0.35456089982813843,1115.3090723368591,7.037756719487966,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G52 360,Qcells North America,Multi-c-Si,0,360.0,333.7,1.951,,,72.0,9.87,46.8,9.35,38.52,0.004935,-0.128232,45.36,1.7619262014109949,9.874803703596417,2.8550496052941352e-11,0.3089390916908206,634.7662505302421,7.89051991719079,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G53 360,Qcells North America,Multi-c-Si,0,360.0,333.7,1.951,,,72.0,9.87,46.8,9.35,38.52,0.004935,-0.128232,45.36,1.7619262014109949,9.874803703596417,2.8550496052941352e-11,0.3089390916908206,634.7662505302421,7.89051991719079,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 365,Qcells North America,Mono-c-Si,0,365.0,337.7,1.82,,,66.0,10.55,44.89,9.97,36.61,0.008229,-0.13642071,46.3,1.743233109453274,10.555768164403577,6.864865877227454e-11,0.3035369931069599,555.1705737267009,3.4290256479498775,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 365,Qcells North America,Mono-c-Si,0,365.0,337.7,1.82,,,66.0,10.55,44.89,9.97,36.61,0.008229,-0.13642071,46.3,1.743233109453274,10.555768164403577,6.864865877227454e-11,0.3035369931069599,555.1705737267009,3.4290256479498775,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10a+ 365,Qcells North America,Mono-c-Si,0,365.0,338.3,1.66,,,60.0,11.07,41.21,10.56,34.58,0.00550179,-0.11860238000000001,45.9,1.5896802731891997,11.07000296468702,6.10566576295211e-11,0.16490104646874687,615759.9465082898,8.156731809642364,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+ 365,Qcells North America,Mono-c-Si,0,365.0,338.3,1.66,,,60.0,11.07,41.21,10.56,34.58,0.00550179,-0.11860238000000001,45.9,1.5896802731891997,11.07000296468702,6.10566576295211e-11,0.16490104646874687,615759.9465082898,8.156731809642364,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/AC 365,Qcells North America,Mono-c-Si,0,365.0,336.6,1.66,,,60.0,11.07,41.21,10.56,34.58,0.00550179,-0.11860238000000001,47.2,1.5896802731891997,11.07000296468702,6.10566576295211e-11,0.16490104646874687,615759.9465082898,8.156731809642364,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/HL 365,Qcells North America,Mono-c-Si,0,365.0,338.3,1.66,,,60.0,11.07,41.21,10.56,34.58,0.00550179,-0.11860238000000001,45.9,1.5896802731891997,11.07000296468702,6.10566576295211e-11,0.16490104646874687,615759.9465082898,8.156731809642364,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9 365,Qcells North America,Mono-c-Si,0,365.0,337.0,1.82,,,66.0,10.55,44.89,9.97,36.61,0.00851385,-0.13974257,46.3,1.7669721891597225,10.555106772327186,9.709300059361812e-11,0.29847319589090854,616.6111020388464,3.7857278991308108,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 365,Qcells North America,Mono-c-Si,0,365.0,337.0,1.82,,,66.0,10.55,44.89,9.97,36.61,0.00851385,-0.13974257,46.3,1.7669721891597225,10.555106772327186,9.709300059361812e-11,0.29847319589090854,616.6111020388464,3.7857278991308108,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G42 365,Qcells North America,Multi-c-Si,0,365.0,335.9,1.9463599999999999,1.97,0.988,72.0,9.83,48.0,9.33,39.1,0.0037354,-0.13871999999999998,45.51,1.8431646186676902,9.831814340687718,4.8036290130547435e-11,0.35785146295540315,1938.8201687425874,6.8139962087514165,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G52 365,Qcells North America,Multi-c-Si,0,365.0,338.4,1.951,,,72.0,9.92,47.03,9.41,38.79,0.00496,-0.1288622,45.36,1.7713389562321888,9.923756492600521,2.9061001692098833e-11,0.29906549636529356,789.7605918607287,7.996282064635923,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G53 365,Qcells North America,Multi-c-Si,0,365.0,338.4,1.951,,,72.0,9.92,47.03,9.41,38.79,0.00496,-0.1288622,45.36,1.7713389562321888,9.923756492600521,2.9061001692098833e-11,0.29906549636529356,789.7605918607287,7.996282064635923,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 370,Qcells North America,Mono-c-Si,0,370.0,342.5,1.82,,,66.0,10.58,44.92,10.03,36.9,0.0082524,-0.13651188,46.3,1.7484930823238896,10.583024395020654,7.334037379202883e-11,0.2721983925394457,952.2100340739446,3.9522614020736215,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 370,Qcells North America,Mono-c-Si,0,370.0,342.5,1.82,,,66.0,10.58,44.92,10.03,36.9,0.0082524,-0.13651188,46.3,1.7484930823238896,10.583024395020654,7.334037379202883e-11,0.2721983925394457,952.2100340739446,3.9522614020736215,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10a+ 370,Qcells North America,Mono-c-Si,0,370.0,343.1,1.66,,,60.0,11.1,41.24,10.62,34.84,0.0055167,-0.11868872000000001,45.9,1.5976389891980858,11.10000251899295,6.836559911407624e-11,0.1388079870413329,611687.5141874043,9.123962962053888,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+ 370,Qcells North America,Mono-c-Si,0,370.0,343.1,1.66,,,60.0,11.1,41.24,10.62,34.84,0.0055167,-0.11868872000000001,45.9,1.5976389891980858,11.10000251899295,6.836559911407624e-11,0.1388079870413329,611687.5141874043,9.123962962053888,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/AC 370,Qcells North America,Mono-c-Si,0,370.0,341.4,1.66,,,60.0,11.1,41.24,10.62,34.84,0.0055167,-0.11868872000000001,47.2,1.5976389891980858,11.10000251899295,6.836559911407624e-11,0.1388079870413329,611687.5141874043,9.123962962053888,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/HL 370,Qcells North America,Mono-c-Si,0,370.0,343.1,1.66,,,60.0,11.1,41.24,10.62,34.84,0.0055167,-0.11868872000000001,45.9,1.5976389891980858,11.10000251899295,6.836559911407624e-11,0.1388079870413329,611687.5141874043,9.123962962053888,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9 370,Qcells North America,Mono-c-Si,0,370.0,341.8,1.82,,,66.0,10.58,44.92,10.03,36.9,0.00853806,-0.13983596000000004,46.3,1.7723557423440683,10.582466434999148,1.0372147713892967e-10,0.26711452557385573,1145.8125373076175,4.310223833188996,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 370,Qcells North America,Mono-c-Si,0,370.0,341.8,1.82,,,66.0,10.58,44.92,10.03,36.9,0.00853806,-0.13983596000000004,46.3,1.7723557423440683,10.582466434999148,1.0372147713892967e-10,0.26711452557385573,1145.8125373076175,4.310223833188996,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G42 370,Qcells North America,Multi-c-Si,0,370.0,340.6,1.9463599999999999,1.97,0.988,72.0,9.89,48.28,9.41,39.32,0.0037582,-0.1395292,45.51,1.8523718159075602,9.890004712585787,4.74016711358417e-11,0.35861535144537415,752646.7144325852,6.639006068136518,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G52 370,Qcells North America,Multi-c-Si,0,370.0,343.2,1.951,,,72.0,9.96,47.26,9.47,39.05,0.004980000000000001,-0.1294924,45.36,1.7756723949242799,9.960011100621918,2.749231089146776e-11,0.2918125034325642,261830.59381989154,7.334640596353645,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPLUS DUO L-G53 370,Qcells North America,Multi-c-Si,0,370.0,343.2,1.951,,,72.0,9.96,47.26,9.47,39.05,0.004980000000000001,-0.1294924,45.36,1.7756723949242799,9.960011100621918,2.749231089146776e-11,0.2918125034325642,261830.59381989154,7.334640596353645,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK-G1+ 370,Qcells North America,Mono-c-Si,0,370.0,345.1,1.73,,,40.0,11.2,41.35,10.66,34.7,0.0058352,-0.10382985,46.6,1.5096473401847332,11.202997478776386,1.417144396643882e-11,0.1810735595448221,676.5765482266497,10.127348732905022,-0.3302,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 375,Qcells North America,Mono-c-Si,0,375.0,347.2,1.82,,,66.0,10.62,44.96,10.09,37.18,0.008283599999999999,-0.13663344,46.3,1.7514545232187966,10.620005454059429,7.546424798105656e-11,0.24369845427571823,474545.383641646,4.148643640444165,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 375,Qcells North America,Mono-c-Si,0,375.0,347.2,1.82,,,66.0,10.62,44.96,10.09,37.18,0.008283599999999999,-0.13663344,46.3,1.7514545232187966,10.620005454059429,7.546424798105656e-11,0.24369845427571823,474545.383641646,4.148643640444165,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10a+ 375,Qcells North America,Mono-c-Si,0,375.0,347.9,1.66,,,60.0,11.14,41.28,10.68,35.1,0.005536580000000001,-0.11880384,45.9,1.6052019840736373,11.140002097591658,7.557817660732223e-11,0.11394976708428273,605196.6908119502,9.978341527001186,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+ 375,Qcells North America,Mono-c-Si,0,375.0,347.9,1.66,,,60.0,11.14,41.28,10.68,35.1,0.005536580000000001,-0.11880384,45.9,1.6052019840736373,11.140002097591658,7.557817660732223e-11,0.11394976708428273,605196.6908119502,9.978341527001186,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK-G10+/HL 375,Qcells North America,Mono-c-Si,0,375.0,347.9,1.66,,,60.0,11.14,41.28,10.68,35.1,0.005536580000000001,-0.11880384,45.9,1.6052019840736373,11.140002097591658,7.557817660732223e-11,0.11394976708428273,605196.6908119502,9.978341527001186,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9 375,Qcells North America,Mono-c-Si,0,375.0,346.5,1.82,,,66.0,10.62,44.96,10.09,37.18,0.00857034,-0.13996048,46.3,1.7763196160970678,10.620005332036179,1.0809294189999413e-10,0.23842367999342515,474907.07095676905,4.617519959899717,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 375,Qcells North America,Mono-c-Si,0,375.0,346.5,1.82,,,66.0,10.62,44.96,10.09,37.18,0.00857034,-0.13996048,46.3,1.7763196160970678,10.620005332036179,1.0809294189999413e-10,0.23842367999342515,474907.07095676905,4.617519959899717,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK L-G42 375,Qcells North America,Mono-c-Si,0,375.0,345.5,1.927,,,72.0,10.0,48.17,9.52,39.4,0.0038,-0.13921129999999998,45.51,1.852106422782555,10.000003304702151,5.067217933328829e-11,0.3304448767355587,999999.9745205542,7.118034377637004,-0.394,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QTRON BLK-G1+ 375,Qcells North America,Mono-c-Si,0,375.0,349.9,1.73,,,40.0,11.24,41.38,10.73,34.96,0.00585604,-0.10390518000000001,46.6,1.513613901948883,11.241160272391708,1.5023532810088515e-11,0.15582660343481744,1509.5516189503044,10.608674769883327,-0.3302,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 380,Qcells North America,Mono-c-Si,0,380.0,352.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.0045581400000000005,-0.12170620000000001,45.7,1.6612106651943503,11.010004079083544,1.7198608534570114e-11,0.36711155774081905,990927.3210113165,4.450017614050359,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 380,Qcells North America,Mono-c-Si,0,380.0,352.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.0045581400000000005,-0.12170620000000001,45.7,1.6612106651943503,11.010004079083544,1.7198608534570114e-11,0.36711155774081905,990927.3210113165,4.450017614050359,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 380,Qcells North America,Mono-c-Si,0,380.0,352.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.0045581400000000005,-0.12170620000000001,45.7,1.6612106651943503,11.010004079083544,1.7198608534570114e-11,0.36711155774081905,990927.3210113165,4.450017614050359,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 380,Qcells North America,Mono-c-Si,0,380.0,352.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.0045581400000000005,-0.12170620000000001,45.7,1.6612106651943503,11.010004079083544,1.7198608534570114e-11,0.36711155774081905,990927.3210113165,4.450017614050359,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 380,Qcells North America,Mono-c-Si,0,380.0,352.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.0045581400000000005,-0.12170620000000001,45.7,1.6612106651943503,11.010004079083544,1.7198608534570114e-11,0.36711155774081905,990927.3210113165,4.450017614050359,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 380,Qcells North America,Mono-c-Si,0,380.0,352.0,1.82,,,66.0,10.65,44.99,10.14,37.46,0.008307,-0.13672461,46.3,1.760203353544108,10.650274212573533,8.448302925270287e-11,0.21362473591045333,8296.867134564533,5.083390934616023,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 380,Qcells North America,Mono-c-Si,0,380.0,352.0,1.82,,,66.0,10.65,44.99,10.14,37.46,0.008307,-0.13672461,46.3,1.760203353544108,10.650274212573533,8.448302925270287e-11,0.21362473591045333,8296.867134564533,5.083390934616023,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G52 380,Qcells North America,Mono-c-Si,0,380.0,351.7,2.015,,,72.0,10.05,47.95,9.57,39.71,0.00402,-0.130424,46.35,1.7721339001790521,10.051607400699302,1.7784745959618948e-11,0.28963453350291196,1810.8908358637345,4.563772297875074,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G53 380,Qcells North America,Mono-c-Si,0,380.0,351.7,2.015,,,72.0,10.05,47.95,9.57,39.71,0.00402,-0.130424,46.35,1.7721339001790521,10.051607400699302,1.7784745959618948e-11,0.28963453350291196,1810.8908358637345,4.563772297875074,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 380,Qcells North America,Mono-c-Si,0,380.0,354.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.00613257,-0.12486740000000002,45.0,1.6603073733652705,11.01000404507069,1.6946113140063687e-11,0.3673804041647611,999991.1764712755,1.47777586647098,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 380,Qcells North America,Mono-c-Si,0,380.0,354.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.00613257,-0.12486740000000002,45.0,1.6603073733652705,11.01000404507069,1.6946113140063687e-11,0.3673804041647611,999991.1764712755,1.47777586647098,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 380,Qcells North America,Mono-c-Si,0,380.0,354.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.00613257,-0.12486740000000002,45.0,1.6603073733652705,11.01000404507069,1.6946113140063687e-11,0.3673804041647611,999991.1764712755,1.47777586647098,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 380,Qcells North America,Mono-c-Si,0,380.0,354.4,1.92,,,66.0,11.01,45.16,10.53,36.09,0.00613257,-0.12486740000000002,45.0,1.6603073733652705,11.01000404507069,1.6946113140063687e-11,0.3673804041647611,999991.1764712755,1.47777586647098,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9 380,Qcells North America,Mono-c-Si,0,380.0,351.3,1.82,,,66.0,10.65,44.99,10.14,37.46,0.00859455,-0.14005387000000002,46.3,1.7846353144110723,10.650003479018093,1.1993410315197763e-10,0.20843519868818497,638117.720938273,5.478375737293467,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 380,Qcells North America,Mono-c-Si,0,380.0,351.3,1.82,,,66.0,10.65,44.99,10.14,37.46,0.00859455,-0.14005387000000002,46.3,1.7846353144110723,10.650003479018093,1.1993410315197763e-10,0.20843519868818497,638117.720938273,5.478375737293467,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK-G1+ 380,Qcells North America,Mono-c-Si,0,380.0,354.7,1.73,,,40.0,11.27,41.41,10.79,35.23,0.00587167,-0.10398050999999998,46.6,1.5058662861217713,11.270002517747356,1.285892275664031e-11,0.1324883749428675,593052.7186640641,9.183444782405449,-0.3302,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 385,Qcells North America,Mono-c-Si,0,385.0,357.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.0045705599999999996,-0.12178705,45.7,1.6691838445690126,11.040004005254728,1.928698879289238e-11,0.3294066167802665,908003.5490658911,5.401452852677067,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 385,Qcells North America,Mono-c-Si,0,385.0,357.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.0045705599999999996,-0.12178705,45.7,1.6691838445690126,11.040004005254728,1.928698879289238e-11,0.3294066167802665,908003.5490658911,5.401452852677067,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 385,Qcells North America,Mono-c-Si,0,385.0,357.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.0045705599999999996,-0.12178705,45.7,1.6691838445690126,11.040004005254728,1.928698879289238e-11,0.3294066167802665,908003.5490658911,5.401452852677067,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 385,Qcells North America,Mono-c-Si,0,385.0,357.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.0045705599999999996,-0.12178705,45.7,1.6691838445690126,11.040004005254728,1.928698879289238e-11,0.3294066167802665,908003.5490658911,5.401452852677067,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 385,Qcells North America,Mono-c-Si,0,385.0,357.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.0045705599999999996,-0.12178705,45.7,1.6691838445690126,11.040004005254728,1.928698879289238e-11,0.3294066167802665,908003.5490658911,5.401452852677067,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 385,Qcells North America,Mono-c-Si,0,385.0,357.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.0045705599999999996,-0.12178705,45.7,1.6691838445690126,11.040004005254728,1.928698879289238e-11,0.3294066167802665,908003.5490658911,5.401452852677067,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 385,Qcells North America,Mono-c-Si,0,385.0,356.8,1.82,,,66.0,10.68,45.03,10.2,37.74,0.0083304,-0.13684617000000002,46.3,1.7685474986404812,10.680003125627431,9.34863347004569e-11,0.1849628776323322,632041.097042017,5.923569687869855,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 385,Qcells North America,Mono-c-Si,0,385.0,356.8,1.82,,,66.0,10.68,45.03,10.2,37.74,0.0083304,-0.13684617000000002,46.3,1.7685474986404812,10.680003125627431,9.34863347004569e-11,0.1849628776323322,632041.097042017,5.923569687869855,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G52 385,Qcells North America,Mono-c-Si,0,385.0,356.8,1.95,,,144.0,10.1,48.21,9.61,40.05,0.00404,-0.1311312,46.35,1.7852162538221625,10.102285437048618,1.881611633389759e-11,0.2747983456145269,1214.4125243545122,5.004586583932211,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G53 385,Qcells North America,Mono-c-Si,0,385.0,356.5,2.015,,,72.0,10.1,48.21,9.61,40.05,0.00404,-0.1311312,46.35,1.7852162538221625,10.102285437048618,1.881611633389759e-11,0.2747983456145269,1214.4125243545122,5.004586583932211,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 385,Qcells North America,Mono-c-Si,0,385.0,358.4,1.947,,,72.0,10.05,48.17,9.57,40.24,0.0034170000000000003,-0.130059,45.63,1.7542989074794069,10.050005511759856,1.1945104319745213e-11,0.25693909886257493,468499.4994800323,2.068407764181023,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 385,Qcells North America,Mono-c-Si,0,385.0,358.4,1.947,,,72.0,10.05,48.17,9.57,40.24,0.0034170000000000003,-0.130059,45.63,1.7542989074794069,10.050005511759856,1.1945104319745213e-11,0.25693909886257493,468499.4994800323,2.068407764181023,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 385,Qcells North America,Mono-c-Si,0,385.0,358.4,1.947,,,72.0,10.05,48.17,9.57,40.24,0.0034170000000000003,-0.130059,45.63,1.7542989074794069,10.050005511759856,1.1945104319745213e-11,0.25693909886257493,468499.4994800323,2.068407764181023,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 385,Qcells North America,Mono-c-Si,0,385.0,359.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.00614928,-0.12495035,45.0,1.668392741220204,11.040004007386448,1.904097871990445e-11,0.3296456772932156,908178.7980226872,2.4211684274033565,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 385,Qcells North America,Mono-c-Si,0,385.0,359.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.00614928,-0.12495035,45.0,1.668392741220204,11.040004007386448,1.904097871990445e-11,0.3296456772932156,908178.7980226872,2.4211684274033565,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 385,Qcells North America,Mono-c-Si,0,385.0,359.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.00614928,-0.12495035,45.0,1.668392741220204,11.040004007386448,1.904097871990445e-11,0.3296456772932156,908178.7980226872,2.4211684274033565,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 385,Qcells North America,Mono-c-Si,0,385.0,359.2,1.92,,,66.0,11.04,45.19,10.59,36.36,0.00614928,-0.12495035,45.0,1.668392741220204,11.040004007386448,1.904097871990445e-11,0.3296456772932156,908178.7980226872,2.4211684274033565,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9 385,Qcells North America,Mono-c-Si,0,385.0,356.1,1.82,,,66.0,10.68,45.03,10.2,37.74,0.00861876,-0.14017839,46.3,1.7938215461973246,10.680003034652598,1.3382809093872456e-10,0.17962079602183192,632201.5288832627,6.395118528939004,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 385,Qcells North America,Mono-c-Si,0,385.0,356.1,1.82,,,66.0,10.68,45.03,10.2,37.74,0.00861876,-0.14017839,46.3,1.7938215461973246,10.680003034652598,1.3382809093872456e-10,0.17962079602183192,632201.5288832627,6.395118528939004,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK-G1+ 385,Qcells North America,Mono-c-Si,0,385.0,359.5,1.73,,,40.0,11.3,41.45,10.85,35.48,0.0058873,-0.10408095,46.6,1.5046763371916543,11.300002127542356,1.2284831196470723e-11,0.11110612321989885,590121.5728014427,8.754258244587634,-0.3302,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 390,Qcells North America,Mono-c-Si,0,390.0,361.9,1.92,,,66.0,11.07,45.23,10.65,36.62,0.00458298,-0.12189485,45.7,1.6771901653951369,11.07000355261482,2.148881549188692e-11,0.2931942227366059,913630.0336475286,6.304933530893073,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 390,Qcells North America,Mono-c-Si,0,390.0,361.9,1.92,,,66.0,11.07,45.23,10.65,36.62,0.00458298,-0.12189485,45.7,1.6771901653951369,11.07000355261482,2.148881549188692e-11,0.2931942227366059,913630.0336475286,6.304933530893073,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 390,Qcells North America,Mono-c-Si,0,390.0,361.9,1.92,,,66.0,11.07,45.23,10.65,36.62,0.00458298,-0.12189485,45.7,1.6771901653951369,11.07000355261482,2.148881549188692e-11,0.2931942227366059,913630.0336475286,6.304933530893073,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 390,Qcells North America,Mono-c-Si,0,390.0,361.9,1.92,,,66.0,11.07,45.23,10.65,36.62,0.00458298,-0.12189485,45.7,1.6771901653951369,11.07000355261482,2.148881549188692e-11,0.2931942227366059,913630.0336475286,6.304933530893073,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 390,Qcells North America,Mono-c-Si,0,390.0,361.9,1.92,,,66.0,11.07,45.23,10.65,36.62,0.00458298,-0.12189485,45.7,1.6771901653951369,11.07000355261482,2.148881549188692e-11,0.2931942227366059,913630.0336475286,6.304933530893073,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 390,Qcells North America,Mono-c-Si,0,390.0,361.9,1.92,,,66.0,11.07,45.23,10.65,36.62,0.00458298,-0.12189485,45.7,1.6771901653951369,11.07000355261482,2.148881549188692e-11,0.2931942227366059,913630.0336475286,6.304933530893073,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9 390,Qcells North America,Mono-c-Si,0,390.0,361.6,1.82,,,66.0,10.71,45.06,10.26,38.01,0.008353800000000002,-0.13693734000000002,46.3,1.7770765485419624,10.710002678317867,1.0416133332808322e-10,0.15668045600104955,626568.7251030569,6.831265449193508,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G9+ 390,Qcells North America,Mono-c-Si,0,390.0,361.6,1.82,,,66.0,10.71,45.06,10.26,38.01,0.008353800000000002,-0.13693734000000002,46.3,1.7770765485419624,10.710002678317867,1.0416133332808322e-10,0.15668045600104955,626568.7251030569,6.831265449193508,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G52 390,Qcells North America,Mono-c-Si,0,390.0,363.5,1.963,,,72.0,10.14,48.48,9.66,40.38,0.004056000000000001,-0.1323504,44.59,1.8070643041998662,10.141303675678431,2.258375381470507e-11,0.26037702818187947,2025.224690482482,6.134670457556903,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G53 390,Qcells North America,Mono-c-Si,0,390.0,361.2,2.015,,,72.0,10.14,48.48,9.66,40.38,0.004056000000000001,-0.1318656,46.35,1.7965294017783517,10.141482111538972,1.9290807593736113e-11,0.26278117600980017,1797.841237070203,5.178460370817752,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 390,Qcells North America,Mono-c-Si,0,390.0,363.1,1.947,,,72.0,10.1,48.44,9.61,40.57,0.003434,-0.13078800000000002,45.63,1.7654681832389598,10.100005237425988,1.2256614531491752e-11,0.24491760761328582,472309.40460502054,2.2406053338088707,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 390,Qcells North America,Mono-c-Si,0,390.0,363.1,1.947,,,72.0,10.1,48.44,9.61,40.57,0.003434,-0.13078800000000002,45.63,1.7654681832389598,10.100005237425988,1.2256614531491752e-11,0.24491760761328582,472309.40460502054,2.2406053338088707,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 390,Qcells North America,Mono-c-Si,0,390.0,363.1,1.947,,,72.0,10.1,48.44,9.61,40.57,0.003434,-0.13078800000000002,45.63,1.7654681832389598,10.100005237425988,1.2256614531491752e-11,0.24491760761328582,472309.40460502054,2.2406053338088707,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 390,Qcells North America,Mono-c-Si,0,390.0,364.0,1.92,,,66.0,11.1,45.23,10.65,36.62,0.0061827,-0.12506095,45.0,1.6745195970901365,11.100003712027158,2.063998308023284e-11,0.30443796253450506,910387.5268856349,3.0489180413698285,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 390,Qcells North America,Mono-c-Si,0,390.0,364.0,1.92,,,66.0,11.1,45.23,10.65,36.62,0.0061827,-0.12506095,45.0,1.6745195970901365,11.100003712027158,2.063998308023284e-11,0.30443796253450506,910387.5268856349,3.0489180413698285,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 390,Qcells North America,Mono-c-Si,0,390.0,364.0,1.92,,,66.0,11.1,45.23,10.65,36.62,0.0061827,-0.12506095,45.0,1.6745195970901365,11.100003712027158,2.063998308023284e-11,0.30443796253450506,910387.5268856349,3.0489180413698285,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 390,Qcells North America,Mono-c-Si,0,390.0,364.0,1.92,,,66.0,11.1,45.23,10.65,36.62,0.0061827,-0.12506095,45.0,1.6745195970901365,11.100003712027158,2.063998308023284e-11,0.30443796253450506,910387.5268856349,3.0489180413698285,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9 390,Qcells North America,Mono-c-Si,0,390.0,360.8,1.82,,,66.0,10.71,45.06,10.26,38.01,0.00864297,-0.14027178000000004,46.3,1.8025557943310613,10.710002585897875,1.4906065012525813e-10,0.1513103093498359,626733.7789126281,7.304054389886368,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 390,Qcells North America,Mono-c-Si,0,390.0,360.8,1.82,,,66.0,10.71,45.06,10.26,38.01,0.00864297,-0.14027178000000004,46.3,1.8025557943310613,10.710002585897875,1.4906065012525813e-10,0.1513103093498359,626733.7789126281,7.304054389886368,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK-G1+ 390,Qcells North America,Mono-c-Si,0,390.0,364.3,1.73,,,40.0,11.34,41.48,10.91,35.74,0.00590814,-0.10415627999999999,46.6,1.5014575197548452,11.340001714823355,1.1391438587637748e-11,0.08832509331536398,584090.989443699,8.055661683520096,-0.3302,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C+ 395,Qcells North America,Mono-c-Si,0,395.0,371.4,1.91,,,66.0,11.1,45.27,10.71,36.88,0.0047729999999999995,-0.11815470000000002,43.6,1.6365154881571489,11.100003266826276,1.0756703339457209e-11,0.2716974542404238,923187.6216265582,3.7464826502015804,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C1+/AC 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 395,Qcells North America,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO L-G52 395,Qcells North America,Mono-c-Si,0,395.0,366.0,2.015,,,72.0,10.19,48.74,9.7,40.71,0.004076,-0.13257280000000002,46.35,1.809387250000368,10.192073436135448,2.031634888561165e-11,0.2493857870740821,1225.618285271561,5.582788404424213,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G53 395,Qcells North America,Mono-c-Si,0,395.0,366.0,2.015,,,72.0,10.19,48.74,9.7,40.71,0.004076,-0.13257280000000002,46.35,1.809387250000368,10.192073436135448,2.031634888561165e-11,0.2493857870740821,1225.618285271561,5.582788404424213,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 395,Qcells North America,Mono-c-Si,0,395.0,367.9,1.947,,,72.0,10.14,48.7,9.66,40.9,0.0034476000000000003,-0.13149000000000002,45.63,1.7779357829957148,10.140004945007,1.2886548037144883e-11,0.23176376068066457,475247.33050510136,2.624078985459997,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 395,Qcells North America,Mono-c-Si,0,395.0,367.9,1.947,,,72.0,10.14,48.7,9.66,40.9,0.0034476000000000003,-0.13149000000000002,45.63,1.7779357829957148,10.140004945007,1.2886548037144883e-11,0.23176376068066457,475247.33050510136,2.624078985459997,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 395,Qcells North America,Mono-c-Si,0,395.0,367.9,1.947,,,72.0,10.14,48.7,9.66,40.9,0.0034476000000000003,-0.13149000000000002,45.63,1.7779357829957148,10.140004945007,1.2886548037144883e-11,0.23176376068066457,475247.33050510136,2.624078985459997,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 395,Qcells North America,Mono-c-Si,0,395.0,368.7,1.92,,,66.0,11.14,45.27,10.71,36.88,0.0062049800000000006,-0.12517155000000002,45.0,1.6819621300205272,11.140003315655246,2.279555551928077e-11,0.2722580162364391,914769.1868778031,3.8530536804077666,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 395,Qcells North America,Mono-c-Si,0,395.0,368.7,1.92,,,66.0,11.14,45.27,10.71,36.88,0.0062049800000000006,-0.12517155000000002,45.0,1.6819621300205272,11.140003315655246,2.279555551928077e-11,0.2722580162364391,914769.1868778031,3.8530536804077666,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 395,Qcells North America,Mono-c-Si,0,395.0,368.7,1.92,,,66.0,11.14,45.27,10.71,36.88,0.0062049800000000006,-0.12517155000000002,45.0,1.6819621300205272,11.140003315655246,2.279555551928077e-11,0.2722580162364391,914769.1868778031,3.8530536804077666,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 395,Qcells North America,Mono-c-Si,0,395.0,368.7,1.92,,,66.0,11.14,45.27,10.71,36.88,0.0062049800000000006,-0.12517155000000002,45.0,1.6819621300205272,11.140003315655246,2.279555551928077e-11,0.2722580162364391,914769.1868778031,3.8530536804077666,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9 395,Qcells North America,Mono-c-Si,0,395.0,365.6,1.82,,,66.0,10.74,45.1,10.32,38.29,0.00866718,-0.1403963,46.3,1.8129005938799487,10.74000097147708,1.6863418462173e-10,0.09044275081030625,999997.5456322879,8.357507529308435,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 395,Qcells North America,Mono-c-Si,0,395.0,365.6,1.82,,,66.0,10.74,45.1,10.32,38.29,0.00866718,-0.1403963,46.3,1.8129005938799487,10.74000097147708,1.6863418462173e-10,0.09044275081030625,999997.5456322879,8.357507529308435,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QTRON BLK-G1+ 395,Qcells North America,Mono-c-Si,0,395.0,369.2,1.73,,,40.0,11.37,41.51,10.97,35.99,0.00592377,-0.10423160999999999,46.6,1.5002205252022973,11.370001301436888,1.0943304093226228e-11,0.06653276350878236,581266.5203901514,7.679244420284596,-0.3302,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C+ 400,Qcells North America,Mono-c-Si,0,400.0,376.2,1.91,,,66.0,11.14,45.3,10.77,37.13,0.0047902000000000005,-0.11823299999999999,43.6,1.64316349454283,11.140002872926274,1.1855442711232375e-11,0.2391082050780936,927176.2801973288,4.540341015069147,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C1+/AC 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/t 400,Qcells North America,Mono-c-Si,0,400.0,367.1,1.92,,,66.0,11.07,45.55,10.5,38.09,0.00449442,-0.12813215,48.1,1.7365865535819907,11.073876319683665,4.4646924447478245e-11,0.20055391288972793,572.7422047516986,8.053147840548135,-0.3736,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 400,Qcells North America,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO L-G52 400,Qcells North America,Mono-c-Si,0,400.0,373.0,1.963,,,72.0,10.24,49.0,9.75,41.04,0.004096000000000001,-0.13377,44.59,1.8320570185299747,10.241785485882424,2.4730325536677804e-11,0.2338042103574549,1340.8984224627382,6.8363496104516495,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G53 400,Qcells North America,Mono-c-Si,0,400.0,373.0,1.963,,,72.0,10.24,49.0,9.75,41.04,0.004096000000000001,-0.13377,44.59,1.8320570185299747,10.241785485882424,2.4730325536677804e-11,0.2338042103574549,1340.8984224627382,6.8363496104516495,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G6 400,Qcells North America,Mono-c-Si,0,400.0,371.7,2.085,,,72.0,10.6,47.89,10.09,39.63,0.00424,-0.13121860000000002,45.15,1.780192367041167,10.601747845143622,2.192756311291944e-11,0.2753775567970979,1670.0577079247494,5.116488025518365,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 400,Qcells North America,Mono-c-Si,0,400.0,371.7,2.085,,,72.0,10.6,47.89,10.09,39.63,0.00424,-0.13121860000000002,45.15,1.780192367041167,10.601747845143622,2.192756311291944e-11,0.2753775567970979,1670.0577079247494,5.116488025518365,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 400,Qcells North America,Mono-c-Si,1,400.0,373.2,2.076,,,72.0,10.6,47.89,10.09,39.63,0.004346,-0.1259507,45.5,1.728542160051282,10.602837376192454,9.801039049529127e-12,0.2866595943019318,1070.9160632709477,2.6020185246527014,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 400,Qcells North America,Mono-c-Si,1,400.0,373.2,2.076,,,72.0,10.6,47.89,10.09,39.63,0.004346,-0.1259507,45.5,1.728542160051282,10.602837376192454,9.801039049529127e-12,0.2866595943019318,1070.9160632709477,2.6020185246527014,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 400,Qcells North America,Mono-c-Si,0,400.0,372.7,1.947,,,72.0,10.19,48.96,9.7,41.23,0.0034646,-0.13219200000000003,45.63,1.7960790409225784,10.192516100843605,1.4699666690983143e-11,0.21740194408706742,880.4598777543129,3.7035807255379507,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 400,Qcells North America,Mono-c-Si,0,400.0,372.7,1.947,,,72.0,10.19,48.96,9.7,41.23,0.0034646,-0.13219200000000003,45.63,1.7960790409225784,10.192516100843605,1.4699666690983143e-11,0.21740194408706742,880.4598777543129,3.7035807255379507,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 400,Qcells North America,Mono-c-Si,0,400.0,372.7,1.947,,,72.0,10.19,48.96,9.7,41.23,0.0034646,-0.13219200000000003,45.63,1.7960790409225784,10.192516100843605,1.4699666690983143e-11,0.21740194408706742,880.4598777543129,3.7035807255379507,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 400,Qcells North America,Mono-c-Si,0,400.0,372.5,2.085,,,72.0,10.55,47.85,10.05,39.82,0.004220000000000001,-0.12775950000000003,45.73,1.738677730007622,10.552194138355953,1.1737838536583768e-11,0.2607476312245378,1253.7439565067957,2.6005548839694854,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 400,Qcells North America,Mono-c-Si,0,400.0,372.5,2.085,,,72.0,10.55,47.85,10.05,39.82,0.004220000000000001,-0.12775950000000003,45.73,1.738677730007622,10.552194138355953,1.1737838536583768e-11,0.2607476312245378,1253.7439565067957,2.6005548839694854,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 400,Qcells North America,Mono-c-Si,0,400.0,372.5,2.085,,,72.0,10.55,47.85,10.05,39.82,0.004220000000000001,-0.12775950000000003,45.73,1.738677730007622,10.552194138355953,1.1737838536583768e-11,0.2607476312245378,1253.7439565067957,2.6005548839694854,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 400,Qcells North America,Mono-c-Si,0,400.0,373.5,1.92,,,66.0,11.17,45.3,10.77,37.13,0.00622169,-0.1252545,45.0,1.6896689488958598,11.170002639379081,2.5387664845681432e-11,0.23621721947012297,999720.652598634,4.7417060016749355,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 400,Qcells North America,Mono-c-Si,0,400.0,373.5,1.92,,,66.0,11.17,45.3,10.77,37.13,0.00622169,-0.1252545,45.0,1.6896689488958598,11.170002639379081,2.5387664845681432e-11,0.23621721947012297,999720.652598634,4.7417060016749355,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 400,Qcells North America,Mono-c-Si,0,400.0,373.5,1.92,,,66.0,11.17,45.3,10.77,37.13,0.00622169,-0.1252545,45.0,1.6896689488958598,11.170002639379081,2.5387664845681432e-11,0.23621721947012297,999720.652598634,4.7417060016749355,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 400,Qcells North America,Mono-c-Si,0,400.0,373.5,1.92,,,66.0,11.17,45.3,10.77,37.13,0.00622169,-0.1252545,45.0,1.6896689488958598,11.170002639379081,2.5387664845681432e-11,0.23621721947012297,999720.652598634,4.7417060016749355,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9 400,Qcells North America,Mono-c-Si,0,400.0,370.4,1.82,,,66.0,10.77,45.14,10.38,38.55,0.00869139,-0.14052082000000002,46.3,1.8226001610979023,10.770047207690238,1.8878590750198233e-10,0.05076793908537627,11582.25401308962,9.329556175001427,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G9+ 400,Qcells North America,Mono-c-Si,0,400.0,370.4,1.82,,,66.0,10.77,45.14,10.38,38.55,0.00869139,-0.14052082000000002,46.3,1.8226001610979023,10.770047207690238,1.8878590750198233e-10,0.05076793908537627,11582.25401308962,9.329556175001427,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C+ 405,Qcells North America,Mono-c-Si,0,405.0,381.0,1.91,,,66.0,11.17,45.34,10.83,37.39,0.0048031,-0.11833740000000001,43.6,1.6508466369424297,11.170002418276697,1.3191243126393922e-11,0.20175326357371634,931911.1139649923,5.428874041917391,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C1+/AC 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 405,Qcells North America,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO L-G52 405,Qcells North America,Mono-c-Si,0,405.0,377.8,1.963,,,72.0,10.28,49.26,9.79,41.36,0.004112,-0.1344798,44.59,1.8439149258817042,10.281699021522666,2.560832840100519e-11,0.22216318670616397,1344.2204807124583,7.104304260065268,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G6 405,Qcells North America,Mono-c-Si,0,405.0,376.4,2.085,,,72.0,10.65,48.14,10.14,39.95,0.004260000000000001,-0.1319036,45.15,1.7918553758586755,10.651670560611436,2.2828917393681838e-11,0.2626965353401398,1674.7181576481444,5.419475826174701,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 405,Qcells North America,Mono-c-Si,0,405.0,376.4,2.085,,,72.0,10.65,48.14,10.14,39.95,0.004260000000000001,-0.1319036,45.15,1.7918553758586755,10.651670560611436,2.2828917393681838e-11,0.2626965353401398,1674.7181576481444,5.419475826174701,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 405,Qcells North America,Mono-c-Si,0,405.0,376.4,2.085,,,72.0,10.65,48.14,10.14,39.95,0.004260000000000001,-0.1319036,45.15,1.7918553758586755,10.651670560611436,2.2828917393681838e-11,0.2626965353401398,1674.7181576481444,5.419475826174701,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 405,Qcells North America,Mono-c-Si,1,405.0,378.0,2.076,,,72.0,10.65,48.14,10.14,39.95,0.004366500000000001,-0.1266082,45.5,1.73980607833607,10.652713465213369,1.0204969810876143e-11,0.27403272946688945,1075.5430366105727,2.900485237861806,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 405,Qcells North America,Mono-c-Si,1,405.0,378.0,2.076,,,72.0,10.65,48.14,10.14,39.95,0.004366500000000001,-0.1266082,45.5,1.73980607833607,10.652713465213369,1.0204969810876143e-11,0.27403272946688945,1075.5430366105727,2.900485237861806,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 405,Qcells North America,Mono-c-Si,0,405.0,377.5,1.947,,,72.0,10.23,49.22,9.75,41.56,0.0034782000000000003,-0.132894,45.63,1.8069641253985294,10.231832949813148,1.5078212759615837e-11,0.20485239770035688,1143.3155725983995,3.87983743559803,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 405,Qcells North America,Mono-c-Si,0,405.0,377.5,1.947,,,72.0,10.23,49.22,9.75,41.56,0.0034782000000000003,-0.132894,45.63,1.8069641253985294,10.231832949813148,1.5078212759615837e-11,0.20485239770035688,1143.3155725983995,3.87983743559803,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 405,Qcells North America,Mono-c-Si,0,405.0,377.5,1.947,,,72.0,10.23,49.22,9.75,41.56,0.0034782000000000003,-0.132894,45.63,1.8069641253985294,10.231832949813148,1.5078212759615837e-11,0.20485239770035688,1143.3155725983995,3.87983743559803,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 405,Qcells North America,Mono-c-Si,0,405.0,377.3,2.085,,,72.0,10.6,48.1,10.09,40.14,0.00424,-0.128427,45.73,1.75080700907145,10.602792377105745,1.2357522773374193e-11,0.24810835405988624,941.8314554495569,2.995116081691517,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 405,Qcells North America,Mono-c-Si,0,405.0,377.3,2.085,,,72.0,10.6,48.1,10.09,40.14,0.00424,-0.128427,45.73,1.75080700907145,10.602792377105745,1.2357522773374193e-11,0.24810835405988624,941.8314554495569,2.995116081691517,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 405,Qcells North America,Mono-c-Si,0,405.0,377.3,2.085,,,72.0,10.6,48.1,10.09,40.14,0.00424,-0.128427,45.73,1.75080700907145,10.602792377105745,1.2357522773374193e-11,0.24810835405988624,941.8314554495569,2.995116081691517,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BFG 405,Qcells North America,Mono-c-Si,1,405.0,379.3,2.085,,,72.0,10.6,48.1,10.09,40.14,0.004346,-0.126984,44.34,1.7497325612448544,10.602812741903847,1.2150448587396209e-11,0.2483454571617088,935.9059618088068,4.015771074881353,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BGT 405,Qcells North America,Mono-c-Si,1,405.0,379.3,2.085,,,72.0,10.6,48.1,10.09,40.14,0.004346,-0.126984,44.34,1.7497325612448544,10.602812741903847,1.2150448587396209e-11,0.2483454571617088,935.9059618088068,4.015771074881353,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 405,Qcells North America,Mono-c-Si,0,405.0,378.3,1.92,,,66.0,11.2,45.34,10.83,37.39,0.006238399999999999,-0.1253651,45.0,1.6978016282502968,11.200002234436964,2.827021613523883e-11,0.19945058159086193,999770.1914737818,5.636158446971529,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 405,Qcells North America,Mono-c-Si,0,405.0,378.3,1.92,,,66.0,11.2,45.34,10.83,37.39,0.006238399999999999,-0.1253651,45.0,1.6978016282502968,11.200002234436964,2.827021613523883e-11,0.19945058159086193,999770.1914737818,5.636158446971529,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 405,Qcells North America,Mono-c-Si,0,405.0,378.3,1.92,,,66.0,11.2,45.34,10.83,37.39,0.006238399999999999,-0.1253651,45.0,1.6978016282502968,11.200002234436964,2.827021613523883e-11,0.19945058159086193,999770.1914737818,5.636158446971529,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 405,Qcells North America,Mono-c-Si,0,405.0,378.3,1.92,,,66.0,11.2,45.34,10.83,37.39,0.006238399999999999,-0.1253651,45.0,1.6978016282502968,11.200002234436964,2.827021613523883e-11,0.19945058159086193,999770.1914737818,5.636158446971529,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 405,Qcells North America,Mono-c-Si,0,405.0,379.7,1.9,,,54.0,13.33,37.91,12.69,31.93,0.0047988,-0.09287949999999999,46.09,1.3360329490447094,13.334714591151391,6.290412377929575e-12,0.13793229027687764,389.9887142855431,4.378779442083969,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 405,Qcells North America,Mono-c-Si,0,405.0,379.7,1.9,,,54.0,13.33,37.91,12.69,31.93,0.0047988,-0.09287949999999999,46.09,1.3360329490447094,13.334714591151391,6.290412377929575e-12,0.13793229027687764,389.9887142855431,4.378779442083969,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 405,Qcells North America,Mono-c-Si,0,405.0,379.7,1.9,,,54.0,13.33,37.91,12.69,31.93,0.0047988,-0.09287949999999999,46.09,1.3360329490447094,13.334714591151391,6.290412377929575e-12,0.13793229027687764,389.9887142855431,4.378779442083969,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 405,Qcells North America,Mono-c-Si,0,405.0,379.7,1.9,,,54.0,13.33,37.91,12.69,31.93,0.0047988,-0.09287949999999999,46.09,1.3360329490447094,13.334714591151391,6.290412377929575e-12,0.13793229027687764,389.9887142855431,4.378779442083969,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 405,Qcells North America,Mono-c-Si,0,405.0,379.7,1.9,,,54.0,13.33,37.91,12.69,31.93,0.0047988,-0.09287949999999999,46.09,1.3360329490447094,13.334714591151391,6.290412377929575e-12,0.13793229027687764,389.9887142855431,4.378779442083969,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10 410,Qcells North America,Mono-c-Si,0,410.0,381.0,1.92,,,66.0,11.2,45.37,10.89,37.64,0.004636799999999999,-0.12227215000000001,45.7,1.707878158178979,11.2000016494607,3.251833520854675e-11,0.14724291252741192,999825.8285556837,9.822735287637995,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a 410,Qcells North America,Mono-c-Si,0,410.0,381.0,1.92,,,66.0,11.2,45.37,10.89,37.64,0.004636799999999999,-0.12227215000000001,45.7,1.707878158178979,11.2000016494607,3.251833520854675e-11,0.14724291252741192,999825.8285556837,9.822735287637995,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+ 410,Qcells North America,Mono-c-Si,0,410.0,381.0,1.92,,,66.0,11.2,45.37,10.89,37.64,0.004636799999999999,-0.12227215000000001,45.7,1.707878158178979,11.2000016494607,3.251833520854675e-11,0.14724291252741192,999825.8285556837,9.822735287637995,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10a+/TS 410,Qcells North America,Mono-c-Si,0,410.0,381.0,1.92,,,66.0,11.2,45.37,10.89,37.64,0.004636799999999999,-0.12227215000000001,45.7,1.707878158178979,11.2000016494607,3.251833520854675e-11,0.14724291252741192,999825.8285556837,9.822735287637995,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C+ 410,Qcells North America,Mono-c-Si,0,410.0,385.9,1.91,,,66.0,11.2,45.37,10.89,37.64,0.004815999999999999,-0.1184157,43.6,1.6581512510987955,11.200001957671494,1.4660143578589095e-11,0.16362196398309423,936108.5026575674,6.314021977427356,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C1+/AC 410,Qcells North America,Mono-c-Si,0,410.0,385.9,1.91,,,66.0,11.2,45.37,10.89,37.64,0.004815999999999999,-0.1184157,43.6,1.6581512510987955,11.200001957671494,1.4660143578589095e-11,0.16362196398309423,936108.5026575674,6.314021977427356,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 410,Qcells North America,Mono-c-Si,0,410.0,385.9,1.91,,,66.0,11.2,45.37,10.89,37.64,0.004815999999999999,-0.1184157,43.6,1.6581512510987955,11.200001957671494,1.4660143578589095e-11,0.16362196398309423,936108.5026575674,6.314021977427356,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 410,Qcells North America,Mono-c-Si,0,410.0,385.9,1.91,,,66.0,11.2,45.37,10.89,37.64,0.004815999999999999,-0.1184157,43.6,1.6581512510987955,11.200001957671494,1.4660143578589095e-11,0.16362196398309423,936108.5026575674,6.314021977427356,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO L-G6 410,Qcells North America,Mono-c-Si,0,410.0,381.2,2.085,,,72.0,10.7,48.38,10.18,40.27,0.00428,-0.13256120000000002,45.15,1.804176156572116,10.702313036631061,2.4094567802029276e-11,0.2490629138912368,1152.1535091317069,5.844819699903146,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 410,Qcells North America,Mono-c-Si,0,410.0,381.2,2.085,,,72.0,10.7,48.38,10.18,40.27,0.00428,-0.13256120000000002,45.15,1.804176156572116,10.702313036631061,2.4094567802029276e-11,0.2490629138912368,1152.1535091317069,5.844819699903146,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 410,Qcells North America,Mono-c-Si,0,410.0,381.2,2.085,,,72.0,10.7,48.38,10.18,40.27,0.00428,-0.13256120000000002,45.15,1.804176156572116,10.702313036631061,2.4094567802029276e-11,0.2490629138912368,1152.1535091317069,5.844819699903146,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 410,Qcells North America,Mono-c-Si,1,410.0,382.8,2.076,,,72.0,10.7,48.39,10.18,40.27,0.004387,-0.1272657,45.5,1.7518671156513488,10.70333806417912,1.074252201109463e-11,0.26146767851463854,838.1217512417273,3.296191594625505,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 410,Qcells North America,Mono-c-Si,1,410.0,382.8,2.076,,,72.0,10.7,48.39,10.18,40.27,0.004387,-0.1272657,45.5,1.7518671156513488,10.70333806417912,1.074252201109463e-11,0.26146767851463854,838.1217512417273,3.296191594625505,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 410,Qcells North America,Mono-c-Si,0,410.0,382.3,1.947,,,72.0,10.28,49.48,9.79,41.88,0.0034952000000000004,-0.133596,45.63,1.8193711902813114,10.282214669492554,1.5797365056395288e-11,0.19306776999785158,896.1773799804089,4.2357646600697665,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 410,Qcells North America,Mono-c-Si,0,410.0,382.3,1.947,,,72.0,10.28,49.48,9.79,41.88,0.0034952000000000004,-0.133596,45.63,1.8193711902813114,10.282214669492554,1.5797365056395288e-11,0.19306776999785158,896.1773799804089,4.2357646600697665,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 410,Qcells North America,Mono-c-Si,0,410.0,382.3,1.947,,,72.0,10.28,49.48,9.79,41.88,0.0034952000000000004,-0.133596,45.63,1.8193711902813114,10.282214669492554,1.5797365056395288e-11,0.19306776999785158,896.1773799804089,4.2357646600697665,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 410,Qcells North America,Mono-c-Si,0,410.0,382.1,2.085,,,72.0,10.65,48.34,10.13,40.46,0.004260000000000001,-0.1290678,45.73,1.7627600016388076,10.653310566911877,1.3039140714370287e-11,0.23457458889396443,754.6198184943579,3.4101017607966626,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 410,Qcells North America,Mono-c-Si,0,410.0,382.1,2.085,,,72.0,10.65,48.34,10.13,40.46,0.004260000000000001,-0.1290678,45.73,1.7627600016388076,10.653310566911877,1.3039140714370287e-11,0.23457458889396443,754.6198184943579,3.4101017607966626,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 410,Qcells North America,Mono-c-Si,0,410.0,382.1,2.085,,,72.0,10.65,48.34,10.13,40.46,0.004260000000000001,-0.1290678,45.73,1.7627600016388076,10.653310566911877,1.3039140714370287e-11,0.23457458889396443,754.6198184943579,3.4101017607966626,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BFG 410,Qcells North America,Mono-c-Si,1,410.0,384.1,2.085,,,72.0,10.65,48.34,10.13,40.46,0.004366500000000001,-0.12761760000000003,44.34,1.7616695730871479,10.653330735995374,1.2819312835580755e-11,0.23481482397574693,750.8184117283814,4.434136004161295,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BGT 410,Qcells North America,Mono-c-Si,1,410.0,384.1,2.085,,,72.0,10.65,48.34,10.13,40.46,0.004366500000000001,-0.12761760000000003,44.34,1.7616695730871479,10.653330735995374,1.2819312835580755e-11,0.23481482397574693,750.8184117283814,4.434136004161295,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G10 410,Qcells North America,Mono-c-Si,0,410.0,383.1,1.92,,,66.0,11.23,45.37,10.89,37.64,0.00625511,-0.12544805,45.0,1.7055448560937096,11.230001820358629,3.144173639806263e-11,0.16206135428905663,999807.8537745649,6.527266764102453,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 410,Qcells North America,Mono-c-Si,0,410.0,383.1,1.92,,,66.0,11.23,45.37,10.89,37.64,0.00625511,-0.12544805,45.0,1.7055448560937096,11.230001820358629,3.144173639806263e-11,0.16206135428905663,999807.8537745649,6.527266764102453,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 410,Qcells North America,Mono-c-Si,0,410.0,383.1,1.92,,,66.0,11.23,45.37,10.89,37.64,0.00625511,-0.12544805,45.0,1.7055448560937096,11.230001820358629,3.144173639806263e-11,0.16206135428905663,999807.8537745649,6.527266764102453,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 410,Qcells North America,Mono-c-Si,0,410.0,383.1,1.92,,,66.0,11.23,45.37,10.89,37.64,0.00625511,-0.12544805,45.0,1.7055448560937096,11.230001820358629,3.144173639806263e-11,0.16206135428905663,999807.8537745649,6.527266764102453,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 410,Qcells North America,Mono-c-Si,0,410.0,384.5,1.9,,,54.0,13.41,38.19,12.76,32.13,0.0048276,-0.09356549999999998,46.09,1.345484382797457,13.415178762743436,6.269935946580233e-12,0.14128488552810914,365.8461328890979,4.301649965411868,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 410,Qcells North America,Mono-c-Si,0,410.0,384.5,1.9,,,54.0,13.41,38.19,12.76,32.13,0.0048276,-0.09356549999999998,46.09,1.345484382797457,13.415178762743436,6.269935946580233e-12,0.14128488552810914,365.8461328890979,4.301649965411868,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 410,Qcells North America,Mono-c-Si,0,410.0,384.5,1.9,,,54.0,13.41,38.19,12.76,32.13,0.0048276,-0.09356549999999998,46.09,1.345484382797457,13.415178762743436,6.269935946580233e-12,0.14128488552810914,365.8461328890979,4.301649965411868,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 410,Qcells North America,Mono-c-Si,0,410.0,384.5,1.9,,,54.0,13.41,38.19,12.76,32.13,0.0048276,-0.09356549999999998,46.09,1.345484382797457,13.415178762743436,6.269935946580233e-12,0.14128488552810914,365.8461328890979,4.301649965411868,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 410,Qcells North America,Mono-c-Si,0,410.0,384.5,1.9,,,54.0,13.41,38.19,12.76,32.13,0.0048276,-0.09356549999999998,46.09,1.345484382797457,13.415178762743436,6.269935946580233e-12,0.14128488552810914,365.8461328890979,4.301649965411868,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C+ 415,Qcells North America,Mono-c-Si,0,415.0,390.7,1.91,,,66.0,11.23,45.41,10.95,37.89,0.0048289,-0.11852009999999999,43.6,1.6656873414940014,11.230001406045618,1.6241780029200103e-11,0.12518774570221777,999882.109041517,7.178770935971046,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10C1+/AC 415,Qcells North America,Mono-c-Si,0,415.0,390.7,1.91,,,66.0,11.23,45.41,10.95,37.89,0.0048289,-0.11852009999999999,43.6,1.6656873414940014,11.230001406045618,1.6241780029200103e-11,0.12518774570221777,999882.109041517,7.178770935971046,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+ 415,Qcells North America,Mono-c-Si,0,415.0,390.7,1.91,,,66.0,11.23,45.41,10.95,37.89,0.0048289,-0.11852009999999999,43.6,1.6656873414940014,11.230001406045618,1.6241780029200103e-11,0.12518774570221777,999882.109041517,7.178770935971046,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO BLK ML-G10+/TS 415,Qcells North America,Mono-c-Si,0,415.0,390.7,1.91,,,66.0,11.23,45.41,10.95,37.89,0.0048289,-0.11852009999999999,43.6,1.6656873414940014,11.230001406045618,1.6241780029200103e-11,0.12518774570221777,999882.109041517,7.178770935971046,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO L-G6 415,Qcells North America,Mono-c-Si,0,415.0,386.0,2.085,,,72.0,10.74,48.63,10.23,40.58,0.004296,-0.1332462,45.15,1.8147966733369385,10.741540892739284,2.4680596041745263e-11,0.23807715048528513,1659.394102319737,6.014471582578932,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 415,Qcells North America,Mono-c-Si,0,415.0,386.0,2.085,,,72.0,10.74,48.63,10.23,40.58,0.004296,-0.1332462,45.15,1.8147966733369385,10.741540892739284,2.4680596041745263e-11,0.23807715048528513,1659.394102319737,6.014471582578932,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 415,Qcells North America,Mono-c-Si,0,415.0,386.0,2.085,,,72.0,10.74,48.63,10.23,40.58,0.004296,-0.1332462,45.15,1.8147966733369385,10.741540892739284,2.4680596041745263e-11,0.23807715048528513,1659.394102319737,6.014471582578932,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 415,Qcells North America,Mono-c-Si,1,415.0,387.6,2.076,,,72.0,10.74,48.63,10.23,40.58,0.004403400000000001,-0.1278969,45.5,1.7619603383826605,10.74249373463894,1.1034943307045038e-11,0.24952845992882597,1074.6675529132924,3.4865466815352257,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 415,Qcells North America,Mono-c-Si,1,415.0,387.6,2.076,,,72.0,10.74,48.63,10.23,40.58,0.004403400000000001,-0.1278969,45.5,1.7619603383826605,10.74249373463894,1.1034943307045038e-11,0.24952845992882597,1074.6675529132924,3.4865466815352257,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G7 415,Qcells North America,Mono-c-Si,0,415.0,387.1,1.947,,,72.0,10.32,49.74,9.83,42.2,0.0035088000000000003,-0.134298,45.63,1.830936439455868,10.322077834357884,1.633854298796321e-11,0.18173691088321708,902.6344848374165,4.48749855094466,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G72 415,Qcells North America,Mono-c-Si,0,415.0,387.1,1.947,,,72.0,10.32,49.74,9.83,42.2,0.0035088000000000003,-0.134298,45.63,1.830936439455868,10.322077834357884,1.633854298796321e-11,0.18173691088321708,902.6344848374165,4.48749855094466,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G73 415,Qcells North America,Mono-c-Si,0,415.0,387.1,1.947,,,72.0,10.32,49.74,9.83,42.2,0.0035088000000000003,-0.134298,45.63,1.830936439455868,10.322077834357884,1.633854298796321e-11,0.18173691088321708,902.6344848374165,4.48749855094466,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 415,Qcells North America,Mono-c-Si,0,415.0,386.9,2.085,,,72.0,10.69,48.59,10.18,40.77,0.004276,-0.12973530000000003,45.73,1.773068292625806,10.692526766044276,1.334686081168101e-11,0.22370017345231036,946.4093027636496,3.5703235064865773,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 415,Qcells North America,Mono-c-Si,0,415.0,386.9,2.085,,,72.0,10.69,48.59,10.18,40.77,0.004276,-0.12973530000000003,45.73,1.773068292625806,10.692526766044276,1.334686081168101e-11,0.22370017345231036,946.4093027636496,3.5703235064865773,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 415,Qcells North America,Mono-c-Si,0,415.0,386.9,2.085,,,72.0,10.69,48.59,10.18,40.77,0.004276,-0.12973530000000003,45.73,1.773068292625806,10.692526766044276,1.334686081168101e-11,0.22370017345231036,946.4093027636496,3.5703235064865773,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BFG 415,Qcells North America,Mono-c-Si,1,415.0,388.8,2.085,,,72.0,10.69,48.59,10.18,40.77,0.0043829,-0.12827760000000002,44.34,1.7719682926616467,10.692545497726675,1.312134548195735e-11,0.22394169323387295,940.4591925540456,4.595687749305678,-0.337,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO L-G83/BGT 415,Qcells North America,Mono-c-Si,1,415.0,388.8,2.085,,,72.0,10.69,48.59,10.18,40.77,0.0043829,-0.12827760000000002,44.34,1.7719682926616467,10.692545497726675,1.312134548195735e-11,0.22394169323387295,940.4591925540456,4.595687749305678,-0.337,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G10 415,Qcells North America,Mono-c-Si,0,415.0,387.9,1.92,,,66.0,11.27,45.41,10.95,37.89,0.00627739,-0.12555865,45.0,1.712824809497741,11.270001567656282,3.4515255557472857e-11,0.12962827578060915,931124.3504225168,7.3041779209489786,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a 415,Qcells North America,Mono-c-Si,0,415.0,387.9,1.92,,,66.0,11.27,45.41,10.95,37.89,0.00627739,-0.12555865,45.0,1.712824809497741,11.270001567656282,3.4515255557472857e-11,0.12962827578060915,931124.3504225168,7.3041779209489786,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10a+ 415,Qcells North America,Mono-c-Si,0,415.0,387.9,1.92,,,66.0,11.27,45.41,10.95,37.89,0.00627739,-0.12555865,45.0,1.712824809497741,11.270001567656282,3.4515255557472857e-11,0.12962827578060915,931124.3504225168,7.3041779209489786,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO ML-G10+ 415,Qcells North America,Mono-c-Si,0,415.0,387.9,1.92,,,66.0,11.27,45.41,10.95,37.89,0.00627739,-0.12555865,45.0,1.712824809497741,11.270001567656282,3.4515255557472857e-11,0.12962827578060915,931124.3504225168,7.3041779209489786,-0.3478,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QTRON BLK M-G2C+ 415,Qcells North America,Mono-c-Si,0,415.0,392.5,1.89,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 415,Qcells North America,Mono-c-Si,0,415.0,392.4,1.9,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 415,Qcells North America,Mono-c-Si,0,415.0,392.5,1.89,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 415,Qcells North America,Mono-c-Si,0,415.0,389.3,1.9,,,54.0,13.49,38.47,12.83,32.34,0.004856399999999999,-0.09425149999999999,46.09,1.3551350668122637,13.495641175970349,6.276074499419047e-12,0.14371437293642939,343.6707006896856,4.261158128671181,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 415,Qcells North America,Mono-c-Si,0,415.0,392.5,1.89,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 415,Qcells North America,Mono-c-Si,0,415.0,392.5,1.89,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 415,Qcells North America,Mono-c-Si,0,415.0,392.5,1.89,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 415,Qcells North America,Mono-c-Si,0,415.0,392.5,1.89,,,54.0,13.49,38.47,12.83,32.34,0.0044517,-0.0842493,46.08,1.2817615384469827,13.498048194511497,1.232792092339667e-12,0.15682405682617517,262.8610087992269,2.0587772498492605,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON M-G2+ 415,Qcells North America,Mono-c-Si,0,415.0,388.8,1.9,,,54.0,13.64,38.21,12.96,32.02,0.004637600000000001,-0.0936145,46.54,1.3415209213729953,13.64683638817448,5.769393108729778e-12,0.15055383436719735,300.3858550896923,3.4829832246862447,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 420,Qcells North America,Mono-c-Si,0,420.0,390.7,2.085,,,72.0,10.79,48.88,10.27,40.89,0.0043159999999999995,-0.1339312,45.15,1.827077334711194,10.792098027998213,2.5863550248046242e-11,0.22676703109010896,1166.2458043859558,6.380738614634652,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 420,Qcells North America,Mono-c-Si,0,420.0,390.7,2.085,,,72.0,10.79,48.88,10.27,40.89,0.0043159999999999995,-0.1339312,45.15,1.827077334711194,10.792098027998213,2.5863550248046242e-11,0.22676703109010896,1166.2458043859558,6.380738614634652,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 420,Qcells North America,Mono-c-Si,1,420.0,392.3,2.076,,,72.0,10.79,48.88,10.27,40.89,0.0044239,-0.1285544,45.5,1.7671194422540601,10.790006375262873,1.0472941487131926e-11,0.23962417613446596,405561.1525216008,2.9933638366975055,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 420,Qcells North America,Mono-c-Si,1,420.0,392.3,2.076,,,72.0,10.79,48.88,10.27,40.89,0.0044239,-0.1285544,45.5,1.7671194422540601,10.790006375262873,1.0472941487131926e-11,0.23962417613446596,405561.1525216008,2.9933638366975055,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 420,Qcells North America,Mono-c-Si,0,420.0,391.7,2.085,,,72.0,10.74,48.84,10.22,41.08,0.004296,-0.1304028,45.73,1.7773894693456047,10.74000639328543,1.2509423021000371e-11,0.21402893791947597,359546.3885907704,2.9703903624294297,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 420,Qcells North America,Mono-c-Si,0,420.0,391.7,2.085,,,72.0,10.74,48.84,10.22,41.08,0.004296,-0.1304028,45.73,1.7773894693456047,10.74000639328543,1.2509423021000371e-11,0.21402893791947597,359546.3885907704,2.9703903624294297,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 420,Qcells North America,Mono-c-Si,0,420.0,391.7,2.085,,,72.0,10.74,48.84,10.22,41.08,0.004296,-0.1304028,45.73,1.7773894693456047,10.74000639328543,1.2509423021000371e-11,0.21402893791947597,359546.3885907704,2.9703903624294297,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BFG 420,Qcells North America,Mono-c-Si,1,420.0,393.6,2.085,,,72.0,10.74,48.84,10.22,41.08,0.004403400000000001,-0.1289376,44.34,1.7838733000613467,10.74299711976831,1.3744898812611934e-11,0.21273745447164127,762.3319936691383,4.955258006071144,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BGT 420,Qcells North America,Mono-c-Si,1,420.0,393.6,2.085,,,72.0,10.74,48.84,10.22,41.08,0.004403400000000001,-0.1289376,44.34,1.7838733000613467,10.74299711976831,1.3744898812611934e-11,0.21273745447164127,762.3319936691383,4.955258006071144,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C+ 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.89,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.9,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.89,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 420,Qcells North America,Mono-c-Si,0,420.0,394.1,1.9,,,54.0,13.58,38.75,12.91,32.54,0.0048888,-0.0949375,46.09,1.3645624315930966,13.586105483109133,6.258367048577677e-12,0.14689398268028842,326.72603567809546,4.181904307099978,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.89,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.89,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.89,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 420,Qcells North America,Mono-c-Si,0,420.0,397.3,1.89,,,54.0,13.58,38.75,12.91,32.54,0.0044814,-0.08486250000000001,46.08,1.2907057511470568,13.588596595641024,1.2294547486368674e-12,0.15999929964155518,252.75010963993122,1.980550931178341,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON M-G2+ 420,Qcells North America,Mono-c-Si,0,420.0,393.6,1.9,,,54.0,13.73,38.48,13.03,32.22,0.004668200000000001,-0.094276,46.54,1.3512093444301425,13.738020391793714,5.825437044354394e-12,0.15285920776653794,261.6776066053509,3.51446950213711,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G6 425,Qcells North America,Mono-c-Si,0,425.0,393.7,2.09,,,72.0,10.83,49.13,10.32,41.2,0.00464607,-0.13029276,46.4,1.8400524513991585,10.831355407368155,2.7398893747789612e-11,0.2154902309992016,1721.8139556435065,10.369441446844334,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 425,Qcells North America,Mono-c-Si,0,425.0,393.7,2.09,,,72.0,10.83,49.13,10.32,41.2,0.00464607,-0.13029276,46.4,1.8400524513991585,10.831355407368155,2.7398893747789612e-11,0.2154902309992016,1721.8139556435065,10.369441446844334,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 425,Qcells North America,Mono-c-Si,0,425.0,393.7,2.09,,,72.0,10.83,49.13,10.32,41.2,0.00464607,-0.13029276,46.4,1.8400524513991585,10.831355407368155,2.7398893747789612e-11,0.2154902309992016,1721.8139556435065,10.369441446844334,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 425,Qcells North America,Mono-c-Si,1,425.0,397.1,2.076,,,72.0,10.83,49.13,10.32,41.2,0.0044403,-0.12921190000000002,45.5,1.784066458168505,10.83226412703311,1.1836202466789312e-11,0.22755715730336798,1088.4742812160812,4.007492477638652,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 425,Qcells North America,Mono-c-Si,1,425.0,397.1,2.076,,,72.0,10.83,49.13,10.32,41.2,0.0044403,-0.12921190000000002,45.5,1.784066458168505,10.83226412703311,1.1836202466789312e-11,0.22755715730336798,1088.4742812160812,4.007492477638652,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 425,Qcells North America,Mono-c-Si,0,425.0,396.4,2.085,,,72.0,10.78,49.09,10.27,41.39,0.004312,-0.13107030000000003,45.73,1.795280405703909,10.782261978060955,1.4300022857301937e-11,0.2018344220549705,961.8904496445349,4.080918585918799,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 425,Qcells North America,Mono-c-Si,0,425.0,396.4,2.085,,,72.0,10.78,49.09,10.27,41.39,0.004312,-0.13107030000000003,45.73,1.795280405703909,10.782261978060955,1.4300022857301937e-11,0.2018344220549705,961.8904496445349,4.080918585918799,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 425,Qcells North America,Mono-c-Si,0,425.0,396.4,2.085,,,72.0,10.78,49.09,10.27,41.39,0.004312,-0.13107030000000003,45.73,1.795280405703909,10.782261978060955,1.4300022857301937e-11,0.2018344220549705,961.8904496445349,4.080918585918799,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BFG 425,Qcells North America,Mono-c-Si,1,425.0,398.5,2.085,,,72.0,10.78,49.09,10.27,41.39,0.0044198,-0.12959760000000003,44.34,1.7941558421250163,10.782279217636663,1.4056618527426607e-11,0.20207999502398824,955.7763783166203,5.110450315347711,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83/BGT 425,Qcells North America,Mono-c-Si,1,425.0,398.5,2.085,,,72.0,10.78,49.09,10.27,41.39,0.0044198,-0.12959760000000003,44.34,1.7941558421250163,10.782279217636663,1.4056618527426607e-11,0.20207999502398824,955.7763783166203,5.110450315347711,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C+ 425,Qcells North America,Mono-c-Si,0,425.0,402.2,1.89,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 425,Qcells North America,Mono-c-Si,0,425.0,402.1,1.9,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 425,Qcells North America,Mono-c-Si,0,425.0,402.2,1.89,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 425,Qcells North America,Mono-c-Si,0,425.0,399.0,1.9,,,54.0,13.66,39.03,12.98,32.74,0.004917599999999999,-0.0956235,46.09,1.3740131744597903,13.666611629254396,6.23941626557277e-12,0.15014279217805915,310.2035019525288,4.107705131752222,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 425,Qcells North America,Mono-c-Si,0,425.0,402.2,1.89,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 425,Qcells North America,Mono-c-Si,0,425.0,402.2,1.89,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 425,Qcells North America,Mono-c-Si,0,425.0,402.2,1.89,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 425,Qcells North America,Mono-c-Si,0,425.0,402.2,1.89,,,54.0,13.66,39.03,12.98,32.74,0.0045078,-0.0854757,46.08,1.2996706523519805,13.66918799590726,1.2258646525015301e-12,0.16325446375970537,242.7140803156831,1.9073359798441836,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON M-G2+ 425,Qcells North America,Mono-c-Si,0,425.0,398.4,1.9,,,54.0,13.81,38.76,13.11,32.42,0.004695400000000001,-0.094962,46.54,1.360160637114999,13.817864525666476,5.754961272580923e-12,0.15608655582875292,274.08586784058963,3.3601640426636,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G6 430,Qcells North America,Mono-c-Si,0,430.0,398.4,2.09,,,72.0,10.92,49.62,10.41,41.85,0.00468468,-0.13159224,46.4,1.8634048779637231,10.921222031693322,2.967691313690116e-11,0.18954025988435189,1693.7201596353443,11.010389812826627,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 430,Qcells North America,Mono-c-Si,0,430.0,398.4,2.09,,,72.0,10.92,49.62,10.41,41.85,0.00468468,-0.13159224,46.4,1.8634048779637231,10.921222031693322,2.967691313690116e-11,0.18954025988435189,1693.7201596353443,11.010389812826627,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 430,Qcells North America,Mono-c-Si,0,430.0,398.4,2.09,,,72.0,10.92,49.62,10.41,41.85,0.00468468,-0.13159224,46.4,1.8634048779637231,10.921222031693322,2.967691313690116e-11,0.18954025988435189,1693.7201596353443,11.010389812826627,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 430,Qcells North America,Mono-c-Si,1,430.0,401.9,2.076,,,72.0,10.88,49.38,10.36,41.5,0.004460800000000001,-0.12986940000000002,45.5,1.795699564798318,10.88274925116099,1.2352828661162981e-11,0.2176099936535685,861.1787797947046,4.334343778736261,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 430,Qcells North America,Mono-c-Si,1,430.0,401.9,2.076,,,72.0,10.88,49.38,10.36,41.5,0.004460800000000001,-0.12986940000000002,45.5,1.795699564798318,10.88274925116099,1.2352828661162981e-11,0.2176099936535685,861.1787797947046,4.334343778736261,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 430,Qcells North America,Mono-c-Si,0,430.0,401.2,2.085,,,72.0,10.83,49.33,10.31,41.7,0.004332000000000001,-0.13171110000000003,45.73,1.8070168828620068,10.832646609487815,1.5007798774358226e-11,0.18983896375895493,776.8263491703207,4.454725946481415,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 430,Qcells North America,Mono-c-Si,0,430.0,401.2,2.085,,,72.0,10.83,49.33,10.31,41.7,0.004332000000000001,-0.13171110000000003,45.73,1.8070168828620068,10.832646609487815,1.5007798774358226e-11,0.18983896375895493,776.8263491703207,4.454725946481415,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 430,Qcells North America,Mono-c-Si,0,430.0,401.2,2.085,,,72.0,10.83,49.33,10.31,41.7,0.004332000000000001,-0.13171110000000003,45.73,1.8070168828620068,10.832646609487815,1.5007798774358226e-11,0.18983896375895493,776.8263491703207,4.454725946481415,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 430,Qcells North America,Mono-c-Si,0,430.0,397.5,2.14,,,78.0,10.54,53.04,9.95,43.2,0.0017391,-0.13753271999999997,46.5,1.9243094240758083,10.550388172410045,1.114979822125116e-11,0.3948681560898552,400.6393059085188,5.58348746040147,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 430,Qcells North America,Mono-c-Si,0,430.0,397.5,2.14,,,78.0,10.54,53.04,9.95,43.2,0.0017391,-0.13753271999999997,46.5,1.9243094240758083,10.550388172410045,1.114979822125116e-11,0.3948681560898552,400.6393059085188,5.58348746040147,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 430,Qcells North America,Mono-c-Si,0,430.0,397.5,2.14,,,78.0,10.54,53.04,9.95,43.2,0.0017391,-0.13753271999999997,46.5,1.9243094240758083,10.550388172410045,1.114979822125116e-11,0.3948681560898552,400.6393059085188,5.58348746040147,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C+ 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.89,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.9,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.89,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 430,Qcells North America,Mono-c-Si,0,430.0,403.8,1.9,,,54.0,13.74,39.32,13.05,32.94,0.004946399999999999,-0.096334,46.09,1.3836478286998795,13.747150048005363,6.199774700042874e-12,0.15412747267997795,296.18143544210614,4.005250036687783,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.89,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.89,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.89,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 430,Qcells North America,Mono-c-Si,0,430.0,407.0,1.89,,,54.0,13.74,39.32,13.05,32.94,0.0045342,-0.0861108,46.08,1.3088199435990246,13.749820299510835,1.2182569194140442e-12,0.1672429247082001,233.99671727721125,1.806172333602077,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON M-G2+ 430,Qcells North America,Mono-c-Si,0,430.0,403.2,1.9,,,54.0,13.89,39.04,13.18,32.62,0.0047226,-0.09564800000000001,46.54,1.3695840947068925,13.898422873329393,5.73758567403627e-12,0.15924409198555087,262.6064001259608,3.2873375759196897,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G6 435,Qcells North America,Mono-c-Si,0,435.0,403.2,2.09,,,72.0,10.97,49.87,10.45,42.17,0.00470613,-0.13225524,46.4,1.8759068486348878,10.9716347601414,3.112576256565382e-11,0.17752378052365006,1191.2670798926538,11.402144521215574,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G62 435,Qcells North America,Mono-c-Si,0,435.0,403.2,2.09,,,72.0,10.97,49.87,10.45,42.17,0.00470613,-0.13225524,46.4,1.8759068486348878,10.9716347601414,3.112576256565382e-11,0.17752378052365006,1191.2670798926538,11.402144521215574,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63 435,Qcells North America,Mono-c-Si,0,435.0,403.2,2.09,,,72.0,10.97,49.87,10.45,42.17,0.00470613,-0.13225524,46.4,1.8759068486348878,10.9716347601414,3.112576256565382e-11,0.17752378052365006,1191.2670798926538,11.402144521215574,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 435,Qcells North America,Mono-c-Si,1,435.0,406.7,2.076,,,72.0,10.92,49.63,10.41,41.81,0.004477200000000001,-0.1305269,45.5,1.8059442549270095,10.9220350157189,1.2632051616212568e-11,0.20708119502154423,1111.208460798392,4.488604793161012,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 435,Qcells North America,Mono-c-Si,1,435.0,406.7,2.076,,,72.0,10.92,49.63,10.41,41.81,0.004477200000000001,-0.1305269,45.5,1.8059442549270095,10.9220350157189,1.2632051616212568e-11,0.20708119502154423,1111.208460798392,4.488604793161012,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G8 435,Qcells North America,Mono-c-Si,0,435.0,406.0,2.085,,,72.0,10.87,49.58,10.36,42.0,0.0043479999999999994,-0.1323786,45.73,1.8170780718874981,10.872001700611587,1.528672064956664e-11,0.18049794545232645,980.1729012936989,4.5751874328738245,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G82 435,Qcells North America,Mono-c-Si,0,435.0,406.0,2.085,,,72.0,10.87,49.58,10.36,42.0,0.0043479999999999994,-0.1323786,45.73,1.8170780718874981,10.872001700611587,1.528672064956664e-11,0.18049794545232645,980.1729012936989,4.5751874328738245,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G83 435,Qcells North America,Mono-c-Si,0,435.0,406.0,2.085,,,72.0,10.87,49.58,10.36,42.0,0.0043479999999999994,-0.1323786,45.73,1.8170780718874981,10.872001700611587,1.528672064956664e-11,0.18049794545232645,980.1729012936989,4.5751874328738245,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 435,Qcells North America,Mono-c-Si,0,435.0,402.3,2.14,,,78.0,10.57,53.07,10.0,43.49,0.00174405,-0.13761051,46.5,1.9293012496449224,10.577981394496492,1.1845485669316433e-11,0.363360220797848,481.2088378231794,6.0696354060802555,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 435,Qcells North America,Mono-c-Si,0,435.0,402.3,2.14,,,78.0,10.57,53.07,10.0,43.49,0.00174405,-0.13761051,46.5,1.9293012496449224,10.577981394496492,1.1845485669316433e-11,0.363360220797848,481.2088378231794,6.0696354060802555,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 435,Qcells North America,Mono-c-Si,0,435.0,402.3,2.14,,,78.0,10.57,53.07,10.0,43.49,0.00174405,-0.13761051,46.5,1.9293012496449224,10.577981394496492,1.1845485669316433e-11,0.363360220797848,481.2088378231794,6.0696354060802555,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C+ 435,Qcells North America,Mono-c-Si,0,435.0,411.9,1.89,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 435,Qcells North America,Mono-c-Si,0,435.0,411.8,1.9,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 435,Qcells North America,Mono-c-Si,0,435.0,411.9,1.89,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 435,Qcells North America,Mono-c-Si,0,435.0,408.6,1.9,,,54.0,13.82,39.6,13.13,33.14,0.0049752,-0.09702000000000001,46.09,1.3926144005876215,13.826980424812744,6.1268547345911756e-12,0.15734023617829787,311.50569341464416,3.85322853182056,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 435,Qcells North America,Mono-c-Si,0,435.0,411.9,1.89,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 435,Qcells North America,Mono-c-Si,0,435.0,411.9,1.89,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 435,Qcells North America,Mono-c-Si,0,435.0,411.9,1.89,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 435,Qcells North America,Mono-c-Si,0,435.0,411.9,1.89,,,54.0,13.82,39.6,13.13,33.14,0.004560600000000001,-0.08672400000000001,46.08,1.3173564041969654,13.829678113828802,1.2041824475439019e-12,0.1704399077525543,243.38208544675874,1.6557008254274992,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON M-G2+ 435,Qcells North America,Mono-c-Si,0,435.0,408.0,1.9,,,54.0,13.97,39.32,13.26,32.82,0.004749800000000001,-0.096334,46.54,1.3785350256291966,13.978251157844372,5.670104140792617e-12,0.1623971422674075,274.95389943296533,3.136791740227693,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BFG 440,Qcells North America,Mono-c-Si,1,440.0,411.5,2.076,,,72.0,10.97,49.87,10.45,42.11,0.0044977,-0.1311581,45.5,1.8173936259728412,10.972459624425017,1.3207835094808706e-11,0.19633934946264486,875.6795012861018,4.832933204254023,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO L-G63/BGT 440,Qcells North America,Mono-c-Si,1,440.0,411.5,2.076,,,72.0,10.97,49.87,10.45,42.11,0.0044977,-0.1311581,45.5,1.8173936259728412,10.972459624425017,1.3207835094808706e-11,0.19633934946264486,875.6795012861018,4.832933204254023,-0.334,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 440,Qcells North America,Mono-c-Si,0,440.0,407.1,2.14,,,78.0,10.59,53.11,10.05,43.77,0.00174735,-0.13771423,46.5,1.9333776566852654,10.595030724182894,1.2356796203593743e-11,0.3346978335545945,704.5606108018646,6.403973008598883,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 440,Qcells North America,Mono-c-Si,0,440.0,407.1,2.14,,,78.0,10.59,53.11,10.05,43.77,0.00174735,-0.13771423,46.5,1.9333776566852654,10.595030724182894,1.2356796203593743e-11,0.3346978335545945,704.5606108018646,6.403973008598883,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 440,Qcells North America,Mono-c-Si,0,440.0,407.1,2.14,,,78.0,10.59,53.11,10.05,43.77,0.00174735,-0.13771423,46.5,1.9333776566852654,10.595030724182894,1.2356796203593743e-11,0.3346978335545945,704.5606108018646,6.403973008598883,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 440,Qcells North America,Mono-c-Si,1,440.0,408.2,2.15,,,78.0,10.46,52.65,9.96,44.18,0.0027928200000000005,-0.14147055,46.1,1.9383254227721594,10.462276164767282,1.6637656219571023e-11,0.24352113243076745,1119.0890626686485,5.128710141764395,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C+ 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.89,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.9,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.89,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F1+/AC 440,Qcells North America,Mono-c-Si,0,440.0,413.4,1.9,,,54.0,13.9,39.88,13.2,33.33,0.005004,-0.09770600000000002,46.09,1.401863395632473,13.907536118476806,6.085562941587383e-12,0.16134413702360215,297.59146138591535,3.748216187330303,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.89,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.89,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.89,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 440,Qcells North America,Mono-c-Si,0,440.0,416.7,1.89,,,54.0,13.9,39.88,13.2,33.33,0.004587000000000001,-0.0873372,46.08,1.3261429997903829,13.910329573391998,1.1962511881057314e-12,0.17444314113446927,234.73957456311948,1.5520084283907427,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 445,Qcells North America,Mono-c-Si,0,445.0,411.8,2.14,,,78.0,10.62,53.15,10.1,44.06,0.0017522999999999998,-0.13781794999999997,46.5,1.9384907557685993,10.623259546066015,1.3076018682045264e-11,0.3048742600717418,993.3168792953518,6.859274225936082,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 445,Qcells North America,Mono-c-Si,0,445.0,411.8,2.14,,,78.0,10.62,53.15,10.1,44.06,0.0017522999999999998,-0.13781794999999997,46.5,1.9384907557685993,10.623259546066015,1.3076018682045264e-11,0.3048742600717418,993.3168792953518,6.859274225936082,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 445,Qcells North America,Mono-c-Si,0,445.0,411.8,2.14,,,78.0,10.62,53.15,10.1,44.06,0.0017522999999999998,-0.13781794999999997,46.5,1.9384907557685993,10.623259546066015,1.3076018682045264e-11,0.3048742600717418,993.3168792953518,6.859274225936082,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 445,Qcells North America,Mono-c-Si,1,445.0,413.0,2.15,,,78.0,10.54,53.15,10.04,44.82,0.00281418,-0.14281405,46.1,1.9611933460045838,10.542052185109053,1.7833019152193564e-11,0.21887652338929353,1124.1472384172719,5.654797191389232,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C+ 445,Qcells North America,Mono-c-Si,0,445.0,421.6,1.89,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2C1+/AC 445,Qcells North America,Mono-c-Si,0,445.0,421.5,1.9,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2F+ 445,Qcells North America,Mono-c-Si,0,445.0,421.6,1.89,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H+ 445,Qcells North America,Mono-c-Si,0,445.0,421.6,1.89,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2H1+/AC 445,Qcells North America,Mono-c-Si,0,445.0,421.6,1.89,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+ 445,Qcells North America,Mono-c-Si,0,445.0,421.6,1.89,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON BLK M-G2+/AC 445,Qcells North America,Mono-c-Si,0,445.0,421.6,1.89,,,54.0,13.98,40.16,13.27,33.52,0.0046134,-0.08795039999999998,46.08,1.33492896367678,13.990997853899625,1.1885087994951206e-12,0.1784049443153984,226.78071558094027,1.449636202350424,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 450,Qcells North America,Mono-c-Si,0,450.0,416.6,2.14,,,78.0,10.65,53.18,10.15,44.34,0.0017572500000000003,-0.13789574,46.5,1.9431740536719566,10.651752502754503,1.3820658558583107e-11,0.275514715754749,1674.3093823047136,7.306019538213495,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 450,Qcells North America,Mono-c-Si,0,450.0,416.6,2.14,,,78.0,10.65,53.18,10.15,44.34,0.0017572500000000003,-0.13789574,46.5,1.9431740536719566,10.651752502754503,1.3820658558583107e-11,0.275514715754749,1674.3093823047136,7.306019538213495,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 450,Qcells North America,Mono-c-Si,0,450.0,416.6,2.14,,,78.0,10.65,53.18,10.15,44.34,0.0017572500000000003,-0.13789574,46.5,1.9431740536719566,10.651752502754503,1.3820658558583107e-11,0.275514715754749,1674.3093823047136,7.306019538213495,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 450,Qcells North America,Mono-c-Si,1,450.0,417.8,2.15,,,78.0,10.54,53.15,10.04,44.82,0.00281418,-0.14281405,46.1,1.9611933460045838,10.542052185109053,1.7833019152193564e-11,0.21887652338929353,1124.1472384172719,5.654797191389232,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 455,Qcells North America,Mono-c-Si,0,455.0,421.4,2.14,,,78.0,10.67,53.22,10.2,44.61,0.00176055,-0.13799946,46.5,1.9473071137251237,10.670004325250126,1.441688175911865e-11,0.24885753766980306,613914.9430100286,7.644444697609286,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 455,Qcells North America,Mono-c-Si,0,455.0,421.4,2.14,,,78.0,10.67,53.22,10.2,44.61,0.00176055,-0.13799946,46.5,1.9473071137251237,10.670004325250126,1.441688175911865e-11,0.24885753766980306,613914.9430100286,7.644444697609286,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 455,Qcells North America,Mono-c-Si,0,455.0,421.4,2.14,,,78.0,10.67,53.22,10.2,44.61,0.00176055,-0.13799946,46.5,1.9473071137251237,10.670004325250126,1.441688175911865e-11,0.24885753766980306,613914.9430100286,7.644444697609286,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 455,Qcells North America,Mono-c-Si,1,455.0,422.5,2.15,,,78.0,10.58,53.41,10.08,45.13,0.0028248600000000002,-0.14351267,46.1,1.9725890437470366,10.581942817485292,1.8350035787962992e-11,0.2088419163038618,1137.2903189869592,5.866482288458753,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 460,Qcells North America,Mono-c-Si,0,460.0,428.0,2.22,,,78.0,11.16,53.48,10.52,43.73,0.001488744,-0.14113372,46.5,1.8805363210890902,11.174252675321055,4.900418106797599e-12,0.3708936092879499,290.4137362133695,-3.3507820885505963,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 460,Qcells North America,Mono-c-Si,0,460.0,428.0,2.22,,,78.0,11.16,53.48,10.52,43.73,0.001488744,-0.14113372,46.5,1.8805363210890902,11.174252675321055,4.900418106797599e-12,0.3708936092879499,290.4137362133695,-3.3507820885505963,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 460,Qcells North America,Mono-c-Si,1,460.0,430.3,2.22,,,78.0,10.95,52.44,10.43,44.11,0.00631815,-0.14059164,45.0,1.9533425419806294,10.95187060728514,2.391345282072033e-11,0.21564855344403017,1262.3449589410152,7.687060931889944,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 460,Qcells North America,Mono-c-Si,0,460.0,428.0,2.22,,,78.0,11.16,53.48,10.52,43.73,0.001488744,-0.14113372,46.5,1.8805363210890902,11.174252675321055,4.900418106797599e-12,0.3708936092879499,290.4137362133695,-3.3507820885505963,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 460,Qcells North America,Mono-c-Si,0,460.0,428.0,2.22,,,78.0,11.16,53.48,10.52,43.73,0.001488744,-0.14113372,46.5,1.8805363210890902,11.174252675321055,4.900418106797599e-12,0.3708936092879499,290.4137362133695,-3.3507820885505963,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 460,Qcells North America,Mono-c-Si,1,460.0,430.3,2.22,,,78.0,10.95,52.44,10.43,44.11,0.00631815,-0.14059164,45.0,1.9533425419806294,10.95187060728514,2.391345282072033e-11,0.21564855344403017,1262.3449589410152,7.687060931889944,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 460,Qcells North America,Mono-c-Si,0,460.0,426.1,2.14,,,78.0,10.7,53.25,10.25,44.89,0.0017655000000000001,-0.13807724999999998,46.5,1.9482339995239946,10.70000389630684,1.4422814918166347e-11,0.22097394356511418,606841.8115943943,7.623619075820457,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 460,Qcells North America,Mono-c-Si,0,460.0,426.1,2.14,,,78.0,10.7,53.25,10.25,44.89,0.0017655000000000001,-0.13807724999999998,46.5,1.9482339995239946,10.70000389630684,1.4422814918166347e-11,0.22097394356511418,606841.8115943943,7.623619075820457,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 460,Qcells North America,Mono-c-Si,0,460.0,426.1,2.14,,,78.0,10.7,53.25,10.25,44.89,0.0017655000000000001,-0.13807724999999998,46.5,1.9482339995239946,10.70000389630684,1.4422814918166347e-11,0.22097394356511418,606841.8115943943,7.623619075820457,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 460,Qcells North America,Mono-c-Si,1,460.0,427.3,2.15,,,78.0,10.63,53.66,10.12,45.44,0.0028382100000000003,-0.14418441999999998,46.1,1.9405658269695185,10.630004411841483,1.041203947207981e-11,0.2072002452541438,499235.8794123436,1.0653351015569412,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 465,Qcells North America,Mono-c-Si,0,465.0,432.7,2.22,,,78.0,11.18,53.51,10.57,44.0,0.001491412,-0.14121289,46.5,1.8841337578894832,11.190697018135417,5.116071168151112e-12,0.3437665216158988,359.28781730374925,-3.036167905230546,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 465,Qcells North America,Mono-c-Si,0,465.0,432.7,2.22,,,78.0,11.18,53.51,10.57,44.0,0.001491412,-0.14121289,46.5,1.8841337578894832,11.190697018135417,5.116071168151112e-12,0.3437665216158988,359.28781730374925,-3.036167905230546,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 465,Qcells North America,Mono-c-Si,1,465.0,435.1,2.22,,,78.0,11.0,52.68,10.47,44.42,0.006347,-0.14123508,45.0,1.9653824164538853,11.00229569444953,2.5034712987986003e-11,0.20369495429454607,976.0203713817255,8.052382240999368,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 465,Qcells North America,Mono-c-Si,0,465.0,432.7,2.22,,,78.0,11.18,53.51,10.57,44.0,0.001491412,-0.14121289,46.5,1.8841337578894832,11.190697018135417,5.116071168151112e-12,0.3437665216158988,359.28781730374925,-3.036167905230546,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 465,Qcells North America,Mono-c-Si,0,465.0,432.7,2.22,,,78.0,11.18,53.51,10.57,44.0,0.001491412,-0.14121289,46.5,1.8841337578894832,11.190697018135417,5.116071168151112e-12,0.3437665216158988,359.28781730374925,-3.036167905230546,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 465,Qcells North America,Mono-c-Si,1,465.0,435.1,2.22,,,78.0,11.0,52.68,10.47,44.42,0.006347,-0.14123508,45.0,1.9653824164538853,11.00229569444953,2.5034712987986003e-11,0.20369495429454607,976.0203713817255,8.052382240999368,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 465,Qcells North America,Mono-c-Si,0,465.0,430.9,2.14,,,78.0,10.73,53.29,10.3,45.16,0.0017704500000000002,-0.13818097,46.5,1.9451542362553038,10.730003508388133,1.3568780996823359e-11,0.19634018482490648,600488.3214830601,7.070114531096352,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 465,Qcells North America,Mono-c-Si,0,465.0,430.9,2.14,,,78.0,10.73,53.29,10.3,45.16,0.0017704500000000002,-0.13818097,46.5,1.9451542362553038,10.730003508388133,1.3568780996823359e-11,0.19634018482490648,600488.3214830601,7.070114531096352,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 465,Qcells North America,Mono-c-Si,0,465.0,430.9,2.14,,,78.0,10.73,53.29,10.3,45.16,0.0017704500000000002,-0.13818097,46.5,1.9451542362553038,10.730003508388133,1.3568780996823359e-11,0.19634018482490648,600488.3214830601,7.070114531096352,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 465,Qcells North America,Mono-c-Si,1,465.0,432.1,2.15,,,78.0,10.67,53.91,10.16,45.75,0.00284889,-0.14485617,46.1,1.9959125387199008,10.672170900398388,1.9745746135490633e-11,0.18667053321649302,917.4877953424211,6.426555022428374,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 470,Qcells North America,Mono-c-Si,0,470.0,437.5,2.22,,,78.0,11.21,53.54,10.62,44.27,0.001495414,-0.14129206,46.5,1.8884692096013447,11.218389473037726,5.399064974354643e-12,0.3166254048790668,423.0743439306231,-2.638306539853635,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 470,Qcells North America,Mono-c-Si,0,470.0,437.5,2.22,,,78.0,11.21,53.54,10.62,44.27,0.001495414,-0.14129206,46.5,1.8884692096013447,11.218389473037726,5.399064974354643e-12,0.3166254048790668,423.0743439306231,-2.638306539853635,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 470,Qcells North America,Mono-c-Si,1,470.0,439.9,2.22,,,78.0,11.04,52.91,10.51,44.73,0.00637008,-0.14185171000000002,45.0,1.969493195967065,11.040006194582975,2.3754060267471562e-11,0.19256233689034208,343187.5944475922,7.5438350553292794,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 470,Qcells North America,Mono-c-Si,0,470.0,437.5,2.22,,,78.0,11.21,53.54,10.62,44.27,0.001495414,-0.14129206,46.5,1.8884692096013447,11.218389473037726,5.399064974354643e-12,0.3166254048790668,423.0743439306231,-2.638306539853635,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 470,Qcells North America,Mono-c-Si,0,470.0,437.5,2.22,,,78.0,11.21,53.54,10.62,44.27,0.001495414,-0.14129206,46.5,1.8884692096013447,11.218389473037726,5.399064974354643e-12,0.3166254048790668,423.0743439306231,-2.638306539853635,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 470,Qcells North America,Mono-c-Si,1,470.0,439.9,2.22,,,78.0,11.04,52.91,10.51,44.73,0.00637008,-0.14185171000000002,45.0,1.969493195967065,11.040006194582975,2.3754060267471562e-11,0.19256233689034208,343187.5944475922,7.5438350553292794,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G9 470,Qcells North America,Mono-c-Si,0,470.0,435.7,2.14,,,78.0,10.75,53.33,10.35,45.43,0.0017737500000000002,-0.13828469,46.5,1.9436013337328168,10.750003095905393,1.3028825676764763e-11,0.17182638135981343,596641.595565146,6.703322737117267,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G92 470,Qcells North America,Mono-c-Si,0,470.0,435.7,2.14,,,78.0,10.75,53.33,10.35,45.43,0.0017737500000000002,-0.13828469,46.5,1.9436013337328168,10.750003095905393,1.3028825676764763e-11,0.17182638135981343,596641.595565146,6.703322737117267,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93 470,Qcells North America,Mono-c-Si,0,470.0,435.7,2.14,,,78.0,10.75,53.33,10.35,45.43,0.0017737500000000002,-0.13828469,46.5,1.9436013337328168,10.750003095905393,1.3028825676764763e-11,0.17182638135981343,596641.595565146,6.703322737117267,-0.3642,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 470,Qcells North America,Mono-c-Si,1,470.0,436.9,2.15,,,78.0,10.71,54.17,10.2,46.06,0.0028595700000000005,-0.14555479000000002,46.1,2.0073263136257182,10.712039479943337,2.030332940934508e-11,0.17688364389465536,928.8759430117224,6.63369935508374,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 475,Qcells North America,Mono-c-Si,0,475.0,442.3,2.22,,,78.0,11.24,53.58,10.66,44.54,0.001499416,-0.14139762,46.5,1.8937788334322914,11.24714235685072,5.74326232466207e-12,0.2906637650565277,457.42053968633735,-2.171346844139174,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 475,Qcells North America,Mono-c-Si,0,475.0,442.3,2.22,,,78.0,11.24,53.58,10.66,44.54,0.001499416,-0.14139762,46.5,1.8937788334322914,11.24714235685072,5.74326232466207e-12,0.2906637650565277,457.42053968633735,-2.171346844139174,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 475,Qcells North America,Mono-c-Si,1,475.0,444.7,2.22,,,78.0,11.08,53.15,10.55,45.03,0.006393160000000001,-0.14249515,45.0,1.980417430370609,11.080006048625425,2.4492639919740248e-11,0.18222496349566875,333805.93776212604,7.779831117960219,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 475,Qcells North America,Mono-c-Si,0,475.0,442.3,2.22,,,78.0,11.24,53.58,10.66,44.54,0.001499416,-0.14139762,46.5,1.8937788334322914,11.24714235685072,5.74326232466207e-12,0.2906637650565277,457.42053968633735,-2.171346844139174,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 475,Qcells North America,Mono-c-Si,0,475.0,442.3,2.22,,,78.0,11.24,53.58,10.66,44.54,0.001499416,-0.14139762,46.5,1.8937788334322914,11.24714235685072,5.74326232466207e-12,0.2906637650565277,457.42053968633735,-2.171346844139174,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 475,Qcells North America,Mono-c-Si,1,475.0,444.7,2.22,,,78.0,11.08,53.15,10.55,45.03,0.006393160000000001,-0.14249515,45.0,1.980417430370609,11.080006048625425,2.4492639919740248e-11,0.18222496349566875,333805.93776212604,7.779831117960219,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G93/BFG 475,Qcells North America,Mono-c-Si,1,475.0,441.7,2.15,,,78.0,10.75,54.42,10.24,46.36,0.00287025,-0.14622654,46.1,2.018290537869986,10.751913935743584,2.0848714672137024e-11,0.1673207056056957,939.7899689676806,6.829795212311967,-0.3575,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 480,Qcells North America,Mono-c-Si,0,480.0,447.1,2.22,,,78.0,11.26,53.61,10.71,44.81,0.001502084,-0.14147679000000002,46.5,1.8972947408787402,11.264589845357827,5.985254679183771e-12,0.2643574380631041,648.5326923421339,-1.8678357651157407,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 480,Qcells North America,Mono-c-Si,0,480.0,447.1,2.22,,,78.0,11.26,53.61,10.71,44.81,0.001502084,-0.14147679000000002,46.5,1.8972947408787402,11.264589845357827,5.985254679183771e-12,0.2643574380631041,648.5326923421339,-1.8678357651157407,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 480,Qcells North America,Mono-c-Si,1,480.0,449.5,2.22,,,78.0,11.12,53.39,10.59,45.33,0.00641624,-0.14313859,45.0,1.9982663798355427,11.121921063156483,2.75749276254627e-11,0.1706123929798755,987.5832781294181,8.80722532576605,-0.3389,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO XL-G10c 480,Qcells North America,Mono-c-Si,0,480.0,447.1,2.22,,,78.0,11.26,53.61,10.71,44.81,0.001502084,-0.14147679000000002,46.5,1.8972947408787402,11.264589845357827,5.985254679183771e-12,0.2643574380631041,648.5326923421339,-1.8678357651157407,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 480,Qcells North America,Mono-c-Si,0,480.0,447.1,2.22,,,78.0,11.26,53.61,10.71,44.81,0.001502084,-0.14147679000000002,46.5,1.8972947408787402,11.264589845357827,5.985254679183771e-12,0.2643574380631041,648.5326923421339,-1.8678357651157407,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 480,Qcells North America,Mono-c-Si,1,480.0,449.5,2.22,,,78.0,11.12,53.39,10.59,45.33,0.00641624,-0.14313859,45.0,1.9982663798355427,11.121921063156483,2.75749276254627e-11,0.1706123929798755,987.5832781294181,8.80722532576605,-0.3389,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO XL-G102 485,Qcells North America,Mono-c-Si,0,485.0,451.9,2.22,,,78.0,11.29,53.64,10.76,45.07,0.001506086,-0.14155596,46.5,1.9013587200713535,11.293047291536562,6.2866421158405e-12,0.23908046863293503,885.7762625947689,-1.5036252768857479,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 485,Qcells North America,Mono-c-Si,0,485.0,451.9,2.22,,,78.0,11.29,53.64,10.76,45.07,0.001506086,-0.14155596,46.5,1.9013587200713535,11.293047291536562,6.2866421158405e-12,0.23908046863293503,885.7762625947689,-1.5036252768857479,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 485,Qcells North America,Mono-c-Si,1,485.0,454.3,2.22,,,78.0,11.16,53.63,10.63,45.63,0.00643932,-0.14378203,45.0,2.002259714333576,11.160004741476616,2.6013296358911085e-11,0.16179360753904617,380816.2117620118,8.24478369653195,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 485,Qcells North America,Mono-c-Si,0,485.0,451.9,2.22,,,78.0,11.29,53.64,10.76,45.07,0.001506086,-0.14155596,46.5,1.9013587200713535,11.293047291536562,6.2866421158405e-12,0.23908046863293503,885.7762625947689,-1.5036252768857479,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 485,Qcells North America,Mono-c-Si,0,485.0,451.9,2.22,,,78.0,11.29,53.64,10.76,45.07,0.001506086,-0.14155596,46.5,1.9013587200713535,11.293047291536562,6.2866421158405e-12,0.23908046863293503,885.7762625947689,-1.5036252768857479,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 485,Qcells North America,Mono-c-Si,1,485.0,454.3,2.22,,,78.0,11.16,53.63,10.63,45.63,0.00643932,-0.14378203,45.0,2.002259714333576,11.160004741476616,2.6013296358911085e-11,0.16179360753904617,380816.2117620118,8.24478369653195,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 490,Qcells North America,Mono-c-Si,0,490.0,456.7,2.22,,,78.0,11.31,53.68,10.81,45.33,0.001508754,-0.14166152000000004,46.5,1.9048095979151016,11.311189937058726,6.509075071586037e-12,0.21529371665590746,2046.3031576492585,-1.250726737551413,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 490,Qcells North America,Mono-c-Si,0,490.0,456.7,2.22,,,78.0,11.31,53.68,10.81,45.33,0.001508754,-0.14166152000000004,46.5,1.9048095979151016,11.311189937058726,6.509075071586037e-12,0.21529371665590746,2046.3031576492585,-1.250726737551413,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 490,Qcells North America,Mono-c-Si,1,490.0,459.1,2.22,,,78.0,11.2,53.86,10.67,45.93,0.006462399999999999,-0.14439865999999998,45.0,2.0104471871311573,11.201776399635541,2.5841556266409638e-11,0.1513943337476828,954.5242729807744,8.173505788324421,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 490,Qcells North America,Mono-c-Si,0,490.0,456.7,2.22,,,78.0,11.31,53.68,10.81,45.33,0.001508754,-0.14166152000000004,46.5,1.9048095979151016,11.311189937058726,6.509075071586037e-12,0.21529371665590746,2046.3031576492585,-1.250726737551413,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 490,Qcells North America,Mono-c-Si,0,490.0,456.7,2.22,,,78.0,11.31,53.68,10.81,45.33,0.001508754,-0.14166152000000004,46.5,1.9048095979151016,11.311189937058726,6.509075071586037e-12,0.21529371665590746,2046.3031576492585,-1.250726737551413,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 490,Qcells North America,Mono-c-Si,1,490.0,459.1,2.22,,,78.0,11.2,53.86,10.67,45.93,0.006462399999999999,-0.14439865999999998,45.0,2.0104471871311573,11.201776399635541,2.5841556266409638e-11,0.1513943337476828,954.5242729807744,8.173505788324421,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 495,Qcells North America,Mono-c-Si,0,495.0,461.5,2.22,,,78.0,11.34,53.71,10.86,45.59,0.0015127559999999999,-0.14174069000000003,46.5,1.9082764523160292,11.340007142455384,6.7769374532050415e-12,0.19063196028765467,302664.92818214477,-0.9568809637084881,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 495,Qcells North America,Mono-c-Si,0,495.0,461.5,2.22,,,78.0,11.34,53.71,10.86,45.59,0.0015127559999999999,-0.14174069000000003,46.5,1.9082764523160292,11.340007142455384,6.7769374532050415e-12,0.19063196028765467,302664.92818214477,-0.9568809637084881,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 495,Qcells North America,Mono-c-Si,1,495.0,463.9,2.22,,,78.0,11.24,54.1,10.71,46.22,0.00648548,-0.1450421,45.0,2.023697763220485,11.240003832400404,2.7584326645003753e-11,0.14180764368950308,415909.48042422987,8.697985294080539,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 495,Qcells North America,Mono-c-Si,0,495.0,461.5,2.22,,,78.0,11.34,53.71,10.86,45.59,0.0015127559999999999,-0.14174069000000003,46.5,1.9082764523160292,11.340007142455384,6.7769374532050415e-12,0.19063196028765467,302664.92818214477,-0.9568809637084881,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 495,Qcells North America,Mono-c-Si,0,495.0,461.5,2.22,,,78.0,11.34,53.71,10.86,45.59,0.0015127559999999999,-0.14174069000000003,46.5,1.9082764523160292,11.340007142455384,6.7769374532050415e-12,0.19063196028765467,302664.92818214477,-0.9568809637084881,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 495,Qcells North America,Mono-c-Si,1,495.0,463.9,2.22,,,78.0,11.24,54.1,10.71,46.22,0.00648548,-0.1450421,45.0,2.023697763220485,11.240003832400404,2.7584326645003753e-11,0.14180764368950308,415909.48042422987,8.697985294080539,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 500,Qcells North America,Mono-c-Si,0,500.0,466.3,2.22,,,78.0,11.36,53.75,10.91,45.85,0.0015154239999999998,-0.14184625,46.5,1.916008225516308,11.36000338844043,7.448374916275521e-12,0.16649244708210195,558180.4480299682,-0.20821177170593141,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 500,Qcells North America,Mono-c-Si,0,500.0,466.3,2.22,,,78.0,11.36,53.75,10.91,45.85,0.0015154239999999998,-0.14184625,46.5,1.916008225516308,11.36000338844043,7.448374916275521e-12,0.16649244708210195,558180.4480299682,-0.20821177170593141,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103/BFG 500,Qcells North America,Mono-c-Si,1,500.0,468.8,2.22,,,78.0,11.28,54.34,10.75,46.51,0.00650856,-0.14568554,45.0,2.0344266356610556,11.280003517017308,2.832693231269984e-11,0.13292425657514767,426326.8110281703,8.901081356354345,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 500,Qcells North America,Mono-c-Si,0,500.0,466.3,2.22,,,78.0,11.36,53.75,10.91,45.85,0.0015154239999999998,-0.14184625,46.5,1.916008225516308,11.36000338844043,7.448374916275521e-12,0.16649244708210195,558180.4480299682,-0.20821177170593141,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 500,Qcells North America,Mono-c-Si,0,500.0,466.3,2.22,,,78.0,11.36,53.75,10.91,45.85,0.0015154239999999998,-0.14184625,46.5,1.916008225516308,11.36000338844043,7.448374916275521e-12,0.16649244708210195,558180.4480299682,-0.20821177170593141,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d/BFG 500,Qcells North America,Mono-c-Si,1,500.0,468.8,2.22,,,78.0,11.28,54.34,10.75,46.51,0.00650856,-0.14568554,45.0,2.0344266356610556,11.280003517017308,2.832693231269984e-11,0.13292425657514767,426326.8110281703,8.901081356354345,-0.3389,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G102 505,Qcells North America,Mono-c-Si,0,505.0,471.1,2.22,,,78.0,11.39,53.78,10.95,46.1,0.001519426,-0.14192542000000002,46.5,1.9218155710561553,11.390002936979972,8.002819088006919e-12,0.14282819826407386,553908.8096203394,0.3535545042921354,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G103 505,Qcells North America,Mono-c-Si,0,505.0,471.1,2.22,,,78.0,11.39,53.78,10.95,46.1,0.001519426,-0.14192542000000002,46.5,1.9218155710561553,11.390002936979972,8.002819088006919e-12,0.14282819826407386,553908.8096203394,0.3535545042921354,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10c 505,Qcells North America,Mono-c-Si,0,505.0,471.1,2.22,,,78.0,11.39,53.78,10.95,46.1,0.001519426,-0.14192542000000002,46.5,1.9218155710561553,11.390002936979972,8.002819088006919e-12,0.14282819826407386,553908.8096203394,0.3535545042921354,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G10d 505,Qcells North America,Mono-c-Si,0,505.0,471.1,2.22,,,78.0,11.39,53.78,10.95,46.1,0.001519426,-0.14192542000000002,46.5,1.9218155710561553,11.390002936979972,8.002819088006919e-12,0.14282819826407386,553908.8096203394,0.3535545042921354,-0.3397,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 560,Qcells North America,Mono-c-Si,1,560.0,516.6,2.66,,,78.0,13.44,53.45,12.73,43.99,0.006706559999999999,-0.14949965000000004,47.0,2.036181804960966,13.446058843110066,5.311997381490462e-11,0.2553603419376971,566.4518795218937,8.377012622505072,-0.3719,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 565,Qcells North America,Mono-c-Si,1,565.0,521.3,2.66,,,78.0,13.47,53.48,12.78,44.22,0.006721530000000001,-0.14958355999999998,47.0,2.040581091607479,13.474320483221879,5.560022982081366e-11,0.2364513160308058,737.1868361892853,8.75233734782621,-0.3719,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113 570,Qcells North America,Mono-c-Si,0,570.0,530.1,2.52,,,52.0,13.49,53.59,12.82,44.46,0.00477546,-0.13911964000000002,46.1,1.9854887477632002,13.494180828949172,2.5461420093798715e-11,0.23372745548743296,754.1527020889886,10.23114823713619,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 570,Qcells North America,Mono-c-Si,1,570.0,528.0,2.66,,,78.0,13.5,53.5,12.83,44.44,0.0055215,-0.1445035,46.6,2.002194628132174,13.503721031132235,3.339622684812824e-11,0.22503614133130637,816.437137147131,8.192504891439878,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113 575,Qcells North America,Mono-c-Si,0,575.0,534.9,2.52,,,52.0,13.51,53.62,12.87,44.68,0.00478254,-0.13919752,46.1,1.9295421976111105,13.513261053765433,1.1490022727567457e-11,0.22645286663318118,938.1563415142994,3.3255438993505733,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 575,Qcells North America,Mono-c-Si,1,575.0,532.8,2.66,,,78.0,13.52,53.53,12.87,44.66,0.0055296799999999995,-0.14458453000000002,46.6,2.0061967218446135,13.522315209204764,3.480502992456409e-11,0.20751942402224227,1211.839835295294,8.535799204358176,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G11S3/BFG 575,Qcells North America,Mono-c-Si,1,575.0,536.2,2.72,,,78.0,13.67,53.52,12.98,44.31,0.0046478000000000005,-0.1396872,45.5,1.9510735444273426,13.675883593754882,1.658776369497878e-11,0.24362663197151663,566.0445416172074,5.808069248632428,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113 580,Qcells North America,Mono-c-Si,0,580.0,539.7,2.52,,,52.0,13.54,53.64,12.92,44.9,0.0047931599999999994,-0.13924944,46.1,1.9923572660528255,13.540756273915804,2.7459838983462406e-11,0.19793288196061729,3543.7052118214433,10.857828760288417,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 580,Qcells North America,Mono-c-Si,1,580.0,537.5,2.66,,,78.0,13.55,53.56,12.92,44.88,0.00554195,-0.14466556000000003,46.6,2.010141626162186,13.551074379346366,3.626841835305557e-11,0.18999167986237298,2396.162508859222,8.872241459919929,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G11S3/BFG 580,Qcells North America,Mono-c-Si,1,580.0,541.0,2.72,,,78.0,13.69,53.55,13.03,44.53,0.0046546,-0.1397655,45.5,1.954238258518625,13.693477061338122,1.7142513287303274e-11,0.2263370572732182,891.1417083416619,6.068967199201087,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113 585,Qcells North America,Mono-c-Si,0,585.0,544.5,2.52,,,52.0,13.57,53.67,12.97,45.12,0.0048037800000000005,-0.13932732,46.1,1.9969185400551421,13.570002448552273,2.886037438773352e-11,0.18043312692953095,999997.9141418111,11.280251496326258,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 585,Qcells North America,Mono-c-Si,1,585.0,542.3,2.66,,,78.0,13.57,53.59,12.97,45.1,0.00555013,-0.14474659,46.6,1.95360343820637,13.570387916989255,1.655907042944509e-11,0.1830921266961449,6404.876334457988,2.157791109093303,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G11S3/BFG 585,Qcells North America,Mono-c-Si,1,585.0,545.8,2.72,,,78.0,13.72,53.57,13.07,44.75,0.004664800000000001,-0.13981770000000002,45.5,1.958570285940192,13.722740863394446,1.8078759812007333e-11,0.20815349625952753,1041.958543841761,6.506062782465008,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113 590,Qcells North America,Mono-c-Si,0,590.0,549.3,2.52,,,52.0,13.59,53.7,13.01,45.33,0.00481086,-0.1394052,46.1,2.003126327831682,13.59009080390781,3.094174552127273e-11,0.1637851677185097,24512.623174248067,11.895504832934106,-0.3604,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 590,Qcells North America,Mono-c-Si,1,590.0,547.1,2.66,,,78.0,13.6,53.63,13.02,45.31,0.0055624,-0.14485463,46.6,2.020974701235751,13.60000203075898,4.062512814970267e-11,0.1493153013642658,999999.8757660983,9.835637837154678,-0.3624,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO XL-G11S3/BFG 590,Qcells North America,Mono-c-Si,1,590.0,550.6,2.72,,,78.0,13.74,53.6,13.12,44.96,0.0046716,-0.13989600000000002,45.5,1.9614772292947105,13.740838898656882,1.8612049186168026e-11,0.1920232307896115,3145.0758226934186,6.735282366956272,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 595,Qcells North America,Mono-c-Si,1,595.0,551.9,2.66,,,78.0,13.62,53.64,13.07,45.53,0.0055705799999999995,-0.14488164,46.6,2.0275101953396057,13.620001670301917,4.4100131123332674e-11,0.12263174951485313,999999.3928064326,10.552793327859103,-0.3624,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO XL-G11S3/BFG 595,Qcells North America,Mono-c-Si,1,595.0,555.4,2.72,,,78.0,13.77,53.63,13.17,45.18,0.0046818,-0.1399743,45.5,1.965733965786328,13.77000239499341,1.951296979298597e-11,0.1739248396365795,999999.7890161381,7.1212388621344145,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 600,Qcells North America,Mono-c-Si,1,600.0,556.7,2.66,,,78.0,13.65,53.67,13.12,45.74,0.00558285,-0.14496267000000002,46.6,2.0335366359146207,13.650003114131758,4.7101641675453504e-11,0.12123877334503123,531429.2509026136,11.125893335242129,-0.3624,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO XL-G11S3/BFG 600,Qcells North America,Mono-c-Si,1,600.0,560.2,2.72,,,78.0,13.8,53.66,13.25,45.3,0.004692000000000001,-0.1400526,45.5,1.9718050136841607,13.800002088990283,2.094797134876653e-11,0.1513730243323817,999998.5460214887,7.719727984417989,-0.348,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QPEAK DUO XL-G113/BFG 605,Qcells North America,Mono-c-Si,1,605.0,559.5,2.66,,,78.0,13.68,53.7,13.17,45.95,0.00682632,-0.15019890000000002,47.0,2.0852029073195566,13.680000925566084,8.948425586347987e-11,0.0676541536539745,999992.1544541431,12.850590492129168,-0.3719,N,2025.7.3,6/23/2025,2.0,first_pass +Qcells North America QTRON XL-G23/BFG 610,Qcells North America,Mono-c-Si,1,610.0,573.8,2.71,,,78.0,13.65,56.11,12.95,47.1,0.005733000000000001,-0.13017520000000002,47.34,1.9238715399905093,13.659211083234327,2.9088151454820907e-12,0.22243340384047214,329.6263739329941,3.2107690275299756,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON XL-G23/BFG 615,Qcells North America,Mono-c-Si,1,615.0,578.6,2.71,,,78.0,13.71,56.39,13.0,47.3,0.005758200000000001,-0.13082480000000002,47.34,1.9332656472736467,13.719820145624755,2.910904883420502e-12,0.22558891705513082,314.9468627554567,3.1816389438636654,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON XL-G23/BFG 620,Qcells North America,Mono-c-Si,1,620.0,583.4,2.71,,,78.0,13.76,56.67,13.05,47.5,0.0057792,-0.1314744,47.34,1.94203299151505,13.769759363295393,2.886090072352556e-12,0.22892828321687317,322.7724068621625,3.0761884984892833,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON XL-G23/BFG 625,Qcells North America,Mono-c-Si,1,625.0,588.2,2.71,,,78.0,13.82,56.95,13.1,47.7,0.005804400000000001,-0.13212400000000002,47.34,1.9514265469521919,13.830383719816131,2.8883551806375457e-12,0.2320356465491642,308.8231091791147,3.047929901843857,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON XL-G23/BFG 630,Qcells North America,Mono-c-Si,1,630.0,593.1,2.71,,,78.0,13.88,57.23,13.15,47.89,0.005829600000000001,-0.13277360000000002,47.34,1.9606299468153294,13.891047679797822,2.8825468494869205e-12,0.2359828326485884,296.4823186030225,2.9958610574815947,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON XL-G23/BFG 640,Qcells North America,Mono-c-Si,1,640.0,602.8,2.71,,,78.0,13.99,57.59,13.26,48.28,0.0058758000000000005,-0.13360880000000003,47.34,1.9742663151521878,14.000477880292296,2.96293348190494e-12,0.22802613397768315,304.45906317506495,3.1619983487017955,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QTRON XL-G23/BFG 645,Qcells North America,Mono-c-Si,1,645.0,607.6,2.71,,,78.0,14.05,58.07,13.31,48.47,0.005901000000000001,-0.1347224,47.34,1.9871394394682393,14.061590393487698,2.822631909617623e-12,0.24702876891334183,299.45093853788154,2.7124448579243743,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Qcells North America QPEAK DUO ML-G12S3/BFG 655,Qcells North America,Mono-c-Si,1,655.0,615.9,3.03,,,66.0,18.33,45.66,17.34,37.78,0.0071487,-0.12008579999999999,43.39,1.674232991197313,18.342882557658438,2.596516502022254e-11,0.15546402377962643,221.2026258452094,6.273522704152172,-0.347,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S3/BFG 660,Qcells North America,Mono-c-Si,1,660.0,620.7,3.03,,,66.0,18.36,45.68,17.39,37.94,0.007160399999999999,-0.1201384,43.39,1.677159499246422,18.37083744513303,2.69812890800616e-11,0.14584246541966134,247.0755475571429,6.586647926597314,-0.347,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S7/BFG 660,Qcells North America,Mono-c-Si,1,660.0,617.4,3.03,,,66.0,18.36,45.68,17.39,37.94,0.0062424,-0.1105456,46.28,1.6179248422054322,18.373419443579056,9.937493963904548e-12,0.15343420366055072,209.92315902386207,6.916982468657017,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S3/BFG 665,Qcells North America,Mono-c-Si,1,665.0,625.5,3.03,,,66.0,18.39,45.7,17.45,38.11,0.007172100000000001,-0.120191,43.39,1.679835703080664,18.398238617684864,2.793827619115469e-11,0.13565565355079506,302.8065621096055,6.867529849177179,-0.347,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S7/BFG 665,Qcells North America,Mono-c-Si,1,665.0,622.3,3.03,,,66.0,18.39,45.7,17.45,38.11,0.0062526000000000005,-0.110594,46.28,1.6204252722154933,18.400576351348406,1.0287296718614817e-11,0.1432630625644386,249.1036506212267,7.198335622564574,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S3/BFG 670,Qcells North America,Mono-c-Si,1,670.0,630.3,3.03,,,66.0,18.42,45.72,17.51,38.27,0.0071838000000000015,-0.1202436,43.39,1.6822777148791999,18.425935422606432,2.8817583205427227e-11,0.12620205087536562,391.65565233131025,7.115383355063417,-0.347,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S7/BFG 670,Qcells North America,Mono-c-Si,1,670.0,627.1,3.03,,,66.0,18.42,45.72,17.51,38.27,0.0062628000000000015,-0.1106424,46.28,1.6227094819228303,18.428039272343558,1.0608666468159484e-11,0.13382114817235302,306.61799428957727,7.446567567963684,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S3/BFG 675,Qcells North America,Mono-c-Si,1,675.0,635.2,3.03,,,66.0,18.45,45.74,17.56,38.43,0.0071955,-0.12029620000000002,43.39,1.6851647822605307,18.454503433627792,2.991587598441906e-11,0.11677985128217724,478.4323416349279,7.422188107402563,-0.347,N,2025.7.3,6/23/2025,4.0,bootstrapping +Qcells North America QPEAK DUO ML-G12S7/BFG 675,Qcells North America,Mono-c-Si,1,675.0,631.9,3.03,,,66.0,18.45,45.74,17.56,38.43,0.006273,-0.1106908,46.28,1.625406015851973,18.456413991559774,1.1010211914545618e-11,0.12441995318137007,357.89697057350145,7.7542487036703,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Rare Manufacturing IW-40-B12345YZZ,Rare Manufacturing,Mono-c-Si,0,40.0,25.7,0.34064447999999997,1.1176,0.3048,16.0,5.54,9.26,5.0,8.0,0.010419632000000002,-0.0554777712,61.3,0.4081918388868935,5.540207782959396,7.298955014403186e-10,0.0009999900001484074,26.662171299235276,-34.49496313103595,-0.898343,Y,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RS520WC,Rayzon Solar Limited,Mono-c-Si,0,520.0,489.1,2.56,,,72.0,13.29,49.22,12.61,41.3,0.0038009399999999996,-0.11891552000000001,44.3,1.7327667547309726,13.297680874479774,6.062147097671839e-12,0.1936547931080398,335.07541560597934,5.681014821093727,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS525144MBC,Rayzon Solar Limited,Mono-c-Si,0,525.0,492.7,2.56,,,72.0,13.16,48.98,12.56,41.93,0.00347424,-0.10991111999999999,45.96,1.697923367645979,13.162964068594523,3.8759709490872904e-12,0.12684294145129668,563.1627824585456,9.822589606742945,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS525WC,Rayzon Solar Limited,Mono-c-Si,0,525.0,493.9,2.56,,,72.0,13.35,49.36,12.68,41.44,0.0038181000000000005,-0.11925376,44.3,1.7373247787543937,13.356800823172579,6.0597176954959505e-12,0.19138534816071115,375.68899267976025,5.633813588173094,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSB525WC,Rayzon Solar Limited,Mono-c-Si,1,525.0,494.1,2.56,,,48.0,13.35,49.36,12.68,41.44,0.0028435500000000002,-0.11061576,45.61,1.6698715496884355,13.358577400303123,1.9199279542870403e-12,0.20354030832725964,316.7933200725222,3.746880318330049,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG525WC,Rayzon Solar Limited,Mono-c-Si,1,525.0,492.0,2.56,,,72.0,13.35,49.36,12.68,41.44,0.0042186,-0.12596671999999998,44.51,1.768629120228115,13.350004804229275,1.0138701673759923e-11,0.1852917645301239,514892.36549353244,6.486697188258902,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS530144MBC,Rayzon Solar Limited,Mono-c-Si,0,530.0,497.5,2.56,,,72.0,13.2,49.13,12.6,42.15,0.0034848,-0.11024772,45.96,1.7047119831532562,13.202780060756636,3.99364153947383e-12,0.11864789307733008,563.3517873685363,10.065427396345548,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS530WC,Rayzon Solar Limited,Mono-c-Si,0,530.0,498.8,2.56,,,72.0,13.41,49.5,12.76,41.58,0.00383526,-0.119592,44.3,1.7412648044311516,13.415283484440188,6.0019855433737625e-12,0.18919834932254503,480.2039080827789,5.503822725894178,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSB530WC,Rayzon Solar Limited,Mono-c-Si,1,530.0,499.0,2.56,,,48.0,13.41,49.5,12.76,41.58,0.00285633,-0.1109295,45.61,1.6736997579094006,13.416960345344897,1.9017704118819552e-12,0.20129683145777943,387.8242214369481,3.6175618428218246,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG530WC,Rayzon Solar Limited,Mono-c-Si,1,530.0,496.8,2.56,,,72.0,13.41,49.5,12.76,41.58,0.0042375600000000005,-0.126324,44.51,1.7680525975024666,13.414665541171383,9.239432697896183e-12,0.1844495413210219,530.1567970788788,3.391769116726557,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS535144MBC,Rayzon Solar Limited,Mono-c-Si,0,535.0,502.3,2.56,,,72.0,13.24,49.28,12.65,42.37,0.0034953600000000003,-0.11058432,45.96,1.710884567194082,13.24222812601352,4.075288222039145e-12,0.11063117259240285,657.3940276178773,10.216986615302117,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS535WC,Rayzon Solar Limited,Mono-c-Si,0,535.0,503.6,2.56,,,72.0,13.47,49.64,12.83,41.72,0.0038524200000000005,-0.11993024000000001,44.3,1.7458337254609164,13.474446057069544,6.000753063327261e-12,0.18697655189218412,566.4736717714565,5.458811383279603,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSB535WC,Rayzon Solar Limited,Mono-c-Si,1,535.0,503.8,2.56,,,48.0,13.47,49.64,12.83,41.72,0.0028691100000000002,-0.11124324,45.61,1.6781054159918438,13.476064844758982,1.901399858979529e-12,0.19903998057936578,442.06713448407186,3.5725553970325206,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG535WC,Rayzon Solar Limited,Mono-c-Si,1,535.0,501.6,2.56,,,72.0,13.47,49.64,12.83,41.72,0.004256520000000001,-0.12668127999999998,44.51,1.7900012485956933,13.473481275703033,1.2116796603861384e-11,0.17920229741421598,693.382304606703,5.653193104835876,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS540144MBC,Rayzon Solar Limited,Mono-c-Si,0,540.0,507.1,2.56,,,72.0,13.3,49.53,12.69,42.62,0.0035112000000000003,-0.11114531999999999,45.96,1.7212803435473794,13.302817287601869,4.206081303768829e-12,0.107354344357533,506.80405672959563,10.469915919685029,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS540WC,Rayzon Solar Limited,Mono-c-Si,0,540.0,508.4,2.56,,,72.0,13.53,49.78,12.91,41.86,0.00386958,-0.12026848000000001,44.3,1.7497918511008095,13.532984194336159,5.945615030604125e-12,0.18483676387115633,838.0290147828043,5.332409727915218,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSB540WC,Rayzon Solar Limited,Mono-c-Si,1,540.0,508.6,2.56,,,48.0,13.53,49.78,12.91,41.86,0.00288189,-0.11155698,45.61,1.6819503664808122,13.53450432643291,1.884063409255604e-12,0.19684522687060516,591.2795105790013,3.4468219334004533,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG540WC,Rayzon Solar Limited,Mono-c-Si,1,540.0,506.4,2.56,,,72.0,13.53,49.78,12.91,41.86,0.004275480000000001,-0.12703856,44.51,1.794031375668973,13.532083233322242,1.2004929364602957e-11,0.17709821161398476,1150.2018682352832,5.527267639063897,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS545144MBC,Rayzon Solar Limited,Mono-c-Si,0,545.0,511.9,2.56,,,72.0,13.33,49.7,12.76,42.77,0.00351912,-0.11152680000000001,45.96,1.7247137757955022,13.331343774235089,4.060340684709443e-12,0.1076707681827837,1068.0749532244151,10.112657774644768,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS545WC,Rayzon Solar Limited,Mono-c-Si,0,545.0,513.2,2.56,,,72.0,13.59,49.91,12.98,42.01,0.00388674,-0.12058256,44.3,1.7543817666133925,13.59219549224416,5.980273012921707e-12,0.18101195285944674,1120.4560085171495,5.339910605429908,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSB545WC,Rayzon Solar Limited,Mono-c-Si,1,545.0,513.4,2.56,,,48.0,13.59,49.91,12.98,42.01,0.00289467,-0.11184830999999999,45.61,1.6863591038218417,13.593647800957804,1.894960899699677e-12,0.19299318350748854,719.0023640069633,3.453629530503017,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG545WC,Rayzon Solar Limited,Mono-c-Si,1,545.0,511.3,2.56,,,72.0,13.59,49.91,12.98,42.01,0.00429444,-0.12737031999999998,44.51,1.7987389626211636,13.591338591916733,1.2075125191497477e-11,0.173291021583293,1759.3296751000014,5.53503152074077,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS550144MBC,Rayzon Solar Limited,Mono-c-Si,0,550.0,516.7,2.56,,,72.0,13.36,49.87,12.83,42.91,0.00352704,-0.11190827999999998,45.96,1.7285856200842689,13.36004548174518,3.947160544836249e-12,0.10875441335345601,31945.981709730415,9.821680213679873,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS550WC,Rayzon Solar Limited,Mono-c-Si,0,550.0,518.0,2.56,,,72.0,13.65,50.06,13.06,42.14,0.0039039000000000005,-0.12094496000000002,44.3,1.7583466687017424,13.650780322287527,5.892791688197171e-12,0.1805671446883979,3158.620835832395,5.1665202499411755,-0.3206,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSB550WC,Rayzon Solar Limited,Mono-c-Si,1,550.0,518.2,2.56,,,48.0,13.65,50.06,13.06,42.14,0.0029074500000000002,-0.11218446000000001,45.61,1.690226641712157,13.65214528366401,1.8674792435886422e-12,0.19248809126886832,1224.7622635253556,3.2815984415025197,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG550WC,Rayzon Solar Limited,Mono-c-Si,1,550.0,516.1,2.56,,,72.0,13.65,50.06,13.06,42.14,0.004313400000000001,-0.12775312,44.51,1.8028099994026485,13.650814311654152,1.190571028292398e-11,0.17287057761898433,92621.63342552945,5.367721898557345,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS555144MBC,Rayzon Solar Limited,Mono-c-Si,0,555.0,521.5,2.56,,,72.0,13.39,50.05,12.9,43.06,0.0035349600000000006,-0.11231219999999999,45.96,1.736987304912721,13.390044817672635,4.1007097341910405e-12,0.10902705998791407,32573.58937210455,10.14625012852761,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS555WC,Rayzon Solar Limited,Mono-c-Si,0,555.0,522.9,2.56,,,72.0,13.71,50.2,13.13,42.28,0.00392106,-0.12128320000000001,44.3,1.7629359204919555,13.710024535545518,5.8937058175891285e-12,0.17843631345180894,99706.89670707683,5.125579875967307,-0.3206,N,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RSB555WC,Rayzon Solar Limited,Mono-c-Si,1,555.0,523.1,2.56,,,48.0,13.71,50.2,13.13,42.28,0.00292023,-0.11249819999999999,45.61,1.6946510818077452,13.711332495365642,1.867788989760664e-12,0.1903242649566123,1958.2400657446733,3.240658189586002,-0.2981,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RSG555WC,Rayzon Solar Limited,Mono-c-Si,1,555.0,520.9,2.56,,,72.0,13.71,50.2,13.13,42.28,0.00433236,-0.12811039999999999,44.51,1.8089663483251082,13.710002295575094,1.2164096331837868e-11,0.16743189170769193,999982.4768139818,5.514497811946992,-0.3367,N,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RS560144MBC,Rayzon Solar Limited,Mono-c-Si,0,560.0,526.4,2.56,,,72.0,13.43,50.22,12.97,43.2,0.00354552,-0.11269367999999999,45.96,1.7444541015643138,13.430030236110138,4.2209564707402765e-12,0.10939269831001916,48589.11678228832,10.380787425224604,-0.3071,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS560144TGC,Rayzon Solar Limited,Mono-c-Si,1,560.0,525.9,2.56,,,72.0,13.48,51.98,12.74,44.01,0.00477192,-0.12256883999999998,45.85,1.8348497546869025,13.489747362563337,6.5985790200395536e-12,0.16723194440981337,231.2714439645723,8.847032116252684,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS560WC,Rayzon Solar Limited,Mono-c-Si,0,560.0,527.7,2.56,,,72.0,13.77,50.34,13.21,42.42,0.00393822,-0.12162144000000003,44.3,1.7694015449732805,13.770002349256638,6.06911406961825e-12,0.17060550654575277,999999.1753171951,5.340384675799114,-0.3206,N,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RSB560WC,Rayzon Solar Limited,Mono-c-Si,1,560.0,527.9,2.56,,,48.0,13.77,50.34,13.21,42.42,0.00293301,-0.11281194000000001,45.61,1.698721896587468,13.770002585185075,1.857934939689734e-12,0.1877397456337689,999999.1977726192,3.1500126409564566,-0.2981,N,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RSG560WC,Rayzon Solar Limited,Mono-c-Si,1,560.0,525.7,2.56,,,72.0,13.77,50.34,13.21,42.42,0.00435132,-0.12846768,44.51,1.8158753162644088,13.770084706245626,1.2568806853370665e-11,0.16808052437926313,27323.485218445578,5.7585236435431435,-0.3367,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS565144TGC,Rayzon Solar Limited,Mono-c-Si,1,565.0,530.8,2.56,,,72.0,13.54,52.18,12.8,44.2,0.0047931599999999994,-0.12304044000000001,45.85,1.8420989709966302,13.549525115160145,6.6490085545260566e-12,0.16532612999298402,235.01194123754266,8.87421862128745,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS570144TGC,Rayzon Solar Limited,Mono-c-Si,1,570.0,535.6,2.56,,,72.0,13.6,52.39,12.86,44.37,0.004814400000000001,-0.12353562000000001,45.85,1.8491375485418915,13.60942238128275,6.642298952261443e-12,0.16598698628074654,239.58094561881595,8.824501331856975,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS575144TGC,Rayzon Solar Limited,Mono-c-Si,1,575.0,540.4,2.56,,,72.0,13.65,52.59,12.91,44.56,0.004832100000000001,-0.12400722000000002,45.85,1.8564232478574452,13.659227379364351,6.6911882990467964e-12,0.1642197540386567,242.92917397958743,8.856286602834805,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS580144TGC,Rayzon Solar Limited,Mono-c-Si,1,580.0,545.2,2.56,,,72.0,13.71,52.8,12.97,44.75,0.00485334,-0.12450240000000001,45.85,1.8638580144821408,13.71904646849305,6.724636795997957e-12,0.16312676719516575,247.2199922997445,8.86050628883152,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS585144TGC,Rayzon Solar Limited,Mono-c-Si,1,585.0,550.1,2.56,,,72.0,13.77,53.01,13.03,44.94,0.00487458,-0.12499758000000001,45.85,1.8712929299415935,13.778867695334922,6.758103940902597e-12,0.16204383938919178,251.62610880903668,8.86471176866557,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS590144TGC,Rayzon Solar Limited,Mono-c-Si,1,590.0,554.9,2.56,,,72.0,13.83,53.21,13.08,45.12,0.00489582,-0.12546918,45.85,1.879011233581558,13.839222368842643,6.850951202180796e-12,0.1609776756225928,241.40449087814585,8.950234676848673,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS600132TGC,Rayzon Solar Limited,Mono-c-Si,1,600.0,569.8,2.7,,,66.0,15.61,48.09,14.76,40.69,0.0051825199999999995,-0.11209779000000002,44.06,1.6348192092366858,15.623051485205284,2.5748832225479683e-12,0.14532885116478922,173.81802395246558,0.714548531677824,-0.2852,N,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RS605132TGC,Rayzon Solar Limited,Mono-c-Si,1,605.0,574.7,2.7,,,66.0,15.64,48.3,14.82,40.85,0.00519248,-0.1125873,44.06,1.6400607092885051,15.651273875115091,2.4998110627290024e-12,0.1471861393839577,204.18810726676318,0.4412299230161252,-0.2852,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS610132TGC,Rayzon Solar Limited,Mono-c-Si,1,610.0,579.5,2.7,,,66.0,15.66,48.51,14.88,41.02,0.005199120000000001,-0.11307681,44.06,1.645027740140854,15.668838822107087,2.4156923241965345e-12,0.14840267250855416,262.9293615367404,0.13234130819080842,-0.2852,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS615132TGC,Rayzon Solar Limited,Mono-c-Si,1,615.0,584.4,2.7,,,66.0,15.69,48.72,14.94,41.18,0.0052090800000000005,-0.11356632000000001,44.06,1.6502864012697966,15.696982498854439,2.34692078522389e-12,0.15022733314893597,337.56781186162016,-0.13370059216027508,-0.2852,N,2025.7.3,6/23/2025,2.0,first_pass +Rayzon Solar Limited RS620132TGC,Rayzon Solar Limited,Mono-c-Si,1,620.0,589.2,2.7,,,66.0,15.72,48.93,15.0,41.35,0.00521904,-0.11405583,44.06,1.6557348252396926,15.72507623309392,2.288233761492271e-12,0.15128147112487478,468.4860908280865,-0.36955548766326923,-0.2852,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS625132TGC,Rayzon Solar Limited,Mono-c-Si,1,625.0,594.1,2.7,,,66.0,15.74,49.14,15.06,41.51,0.005225680000000001,-0.11454534,44.06,1.6605482314789075,15.742553636738949,2.206574434683174e-12,0.15320886496537683,944.3424340875031,-0.6937857059908447,-0.2852,N,2025.7.3,6/23/2025,4.0,first_pass +Rayzon Solar Limited RS630132TGC,Rayzon Solar Limited,Mono-c-Si,1,630.0,599.0,2.7,,,66.0,15.77,49.35,15.12,41.68,0.005235640000000001,-0.11503485000000001,44.06,1.6660111838346505,15.770597903434407,2.152756324250591e-12,0.15423831453978093,4068.1098370078194,-0.9232450603877915,-0.2852,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC275TP2 BLK,REC Group,Multi-c-Si,0,275.0,253.7,1.62,1.675,0.997,60.0,9.52,38.2,8.74,31.5,0.004093599999999999,-0.110016,45.38,1.4741212714604575,9.547029059562218,5.0741095457611633e-11,0.2486116507365001,87.56438333526557,8.022038051621674,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC280TP2,REC Group,Multi-c-Si,0,280.0,258.4,1.62,1.675,0.997,60.0,9.61,38.4,8.84,31.7,0.004132299999999999,-0.110592,45.38,1.4811980858844729,9.635436718316923,5.07625918523066e-11,0.24316477652238003,91.86772802958498,7.936510256586838,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC280TP2 BLK,REC Group,Multi-c-Si,0,280.0,258.4,1.62,1.675,0.997,60.0,9.61,38.4,8.84,31.7,0.004132299999999999,-0.110592,45.38,1.4811980858844729,9.635436718316923,5.07625918523066e-11,0.24316477652238003,91.86772802958498,7.936510256586838,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC285TP2,REC Group,Multi-c-Si,0,285.0,263.2,1.62,1.675,0.997,60.0,9.66,38.6,8.95,31.9,0.0041538,-0.11116799999999999,45.38,1.4842238501762142,9.680153317599196,4.741172934427535e-11,0.23938207094173836,114.74194332085888,7.270795617703697,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC285TP2 BLK,REC Group,Multi-c-Si,0,285.0,263.2,1.62,1.675,0.997,60.0,9.66,38.6,8.95,31.9,0.0041538,-0.11116799999999999,45.38,1.4842238501762142,9.680153317599196,4.741172934427535e-11,0.23938207094173836,114.74194332085888,7.270795617703697,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC290TP2,REC Group,Multi-c-Si,0,290.0,267.9,1.62,1.675,0.997,60.0,9.71,38.8,9.05,32.1,0.0041753,-0.11174399999999998,45.38,1.4882182657162684,9.725812497441018,4.49876896764043e-11,0.23552506682948138,144.62917266459436,6.749748291859198,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC290TP2 BLK,REC Group,Multi-c-Si,0,290.0,267.9,1.62,1.675,0.997,60.0,9.71,38.8,9.05,32.1,0.0041753,-0.11174399999999998,45.38,1.4882182657162684,9.725812497441018,4.49876896764043e-11,0.23552506682948138,144.62917266459436,6.749748291859198,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC290TP2M,REC Group,Mono-c-Si,0,290.0,266.3,1.62,,,60.0,9.45,39.0,8.9,32.6,0.0036855,-0.11349,45.68,1.5276807306056592,9.456464407156997,7.625654351643484e-11,0.19304392221044042,282.20145414874827,10.476691680138707,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC295NP,REC Group,Mono-c-Si,0,295.0,275.3,1.62,,,60.0,9.76,39.4,9.04,32.7,0.0039040000000000004,-0.10480400000000001,44.11,1.4709849578663963,9.781102415171922,2.1955884628561377e-11,0.2356234986139401,108.97735338603528,9.158129458144876,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC295TP2,REC Group,Multi-c-Si,0,295.0,272.7,1.62,1.675,0.997,60.0,9.76,39.0,9.14,32.3,0.0041968,-0.11231999999999999,45.38,1.493122320604518,9.772374330851234,4.33249980363002e-11,0.23160969267304019,182.6774020341437,6.362951337972708,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC295TP2 BLK,REC Group,Multi-c-Si,0,295.0,272.7,1.62,,,60.0,9.76,39.0,9.14,32.3,0.0041968,-0.11231999999999999,45.38,1.493122320604518,9.772374330851234,4.33249980363002e-11,0.23160969267304019,182.6774020341437,6.362951337972708,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC295TP2M,REC Group,Mono-c-Si,0,295.0,271.0,1.62,,,60.0,9.58,39.2,9.0,32.8,0.0037362,-0.11407199999999999,45.68,1.5383148836391995,9.587759837363507,8.073642223799679e-11,0.1867832014814939,230.5954399984854,10.874537065296375,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC300NP,REC Group,Mono-c-Si,0,300.0,280.1,1.62,,,60.0,9.85,39.6,9.1,33.0,0.00394,-0.10533600000000001,44.11,1.4835199485027117,9.871501233783437,2.4198446204975245e-11,0.21739535451417727,99.59169161602175,9.95126767380651,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC300TP2,REC Group,Multi-c-Si,0,300.0,277.4,1.62,1.675,0.997,60.0,9.82,39.2,9.24,32.5,0.0042226,-0.112896,45.38,1.4980285398843636,9.82902134780842,4.177928401315111e-11,0.22752413928160678,247.66666032599048,5.980172340077121,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC300TP2 BLK,REC Group,Multi-c-Si,0,300.0,277.4,1.62,,,60.0,9.82,39.2,9.24,32.5,0.0042226,-0.112896,45.38,1.4980285398843636,9.82902134780842,4.177928401315111e-11,0.22752413928160678,247.66666032599048,5.980172340077121,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC300TP2M,REC Group,Mono-c-Si,0,300.0,275.7,1.62,,,60.0,9.7,39.5,9.1,33.0,0.0037829999999999995,-0.11494499999999999,45.68,1.5499255346951797,9.708844143847585,8.140768537758063e-11,0.19215572414753326,210.75081954560258,10.842790826391969,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC305NP,REC Group,Mono-c-Si,0,305.0,284.8,1.62,,,60.0,9.93,39.9,9.17,33.3,0.003972,-0.106134,44.11,1.4962592719432992,9.951350911569616,2.5040594744819976e-11,0.21093199239444826,98.10148363460885,10.186204542822258,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC305NP Black,REC Group,Mono-c-Si,0,305.0,284.4,1.62,,,60.0,10.06,39.3,9.17,33.3,0.0036216,-0.104931,44.45,1.4916011965966796,10.0807423759536,3.431257968194466e-11,0.14120415782203435,68.48365831967736,12.600571922167724,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC305TP2M,REC Group,Mono-c-Si,0,305.0,280.4,1.62,,,60.0,9.8,39.7,9.17,33.3,0.0038220000000000003,-0.115527,45.68,1.5632487792897423,9.809585992200686,8.961552901631427e-11,0.17393374232071568,177.81682589936594,11.623422561676518,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC310NP,REC Group,Mono-c-Si,0,310.0,289.6,1.62,,,60.0,10.01,40.2,9.24,33.6,0.004004,-0.10693200000000001,44.11,1.5090001685694108,10.03117952802355,2.589966419911454e-11,0.20456667243153343,96.68357082948337,10.417886497648608,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC310NP Black,REC Group,Mono-c-Si,0,310.0,289.2,1.62,,,60.0,10.12,39.7,9.24,33.6,0.0036431999999999997,-0.10599900000000001,44.45,1.5045077263050124,10.140891127275433,3.323796420128238e-11,0.14702526277411276,71.2214154767051,12.250250323753008,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC310TP2M,REC Group,Mono-c-Si,0,310.0,285.2,1.62,,,60.0,9.9,39.8,9.26,33.5,0.0038610000000000003,-0.11581799999999998,45.68,1.57044767769008,9.909144702288918,9.53568210083874e-11,0.15800143800386687,171.05141476093505,12.093919900278614,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC315NP,REC Group,Mono-c-Si,0,315.0,294.4,1.62,,,60.0,10.09,40.5,9.31,33.9,0.0040360000000000005,-0.10773,44.11,1.5217423641312644,10.11098775335228,2.6775572347621596e-11,0.19829723450443196,95.33269566873038,10.64633686562468,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC315NP Black,REC Group,Mono-c-Si,0,315.0,294.0,1.62,,,60.0,10.09,40.5,9.31,33.9,0.0036324,-0.10813500000000001,44.45,1.5174652462342948,10.111163517987242,2.4837486224732185e-11,0.19932446727607014,95.03069775785056,9.616896673649247,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC315TP2M,REC Group,Mono-c-Si,0,315.0,292.8,1.617,,,60.0,10.05,39.9,9.36,33.7,0.00402,-0.114114,44.57,1.5375676450348081,10.061567729902936,5.2404243464253085e-11,0.15107636190222093,131.25457296388353,8.582346729444088,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC315TP3M,REC Group,Mono-c-Si,0,315.0,294.5,1.61,,,60.0,10.29,38.7,9.38,33.6,0.0039102,-0.10216800000000001,44.95,1.462078434988277,10.296851007830254,3.09926798378027e-11,0.04301101117642259,64.60119689315025,12.742043988059788,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC315TP3M Black,REC Group,Mono-c-Si,0,315.0,294.5,1.61,,,60.0,10.29,38.7,9.38,33.6,0.0039102,-0.10216800000000001,44.95,1.462078434988277,10.296851007830254,3.09926798378027e-11,0.04301101117642259,64.60119689315025,12.742043988059788,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC320NP,REC Group,Mono-c-Si,0,320.0,299.2,1.62,,,60.0,10.18,40.8,9.37,34.2,0.004072,-0.108528,44.11,1.5361149437971626,10.201950377580806,2.841848657893216e-11,0.19161228239732356,88.86466914245962,11.11164930484592,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC320NP Black,REC Group,Mono-c-Si,0,320.0,298.8,1.617,,,60.0,10.18,40.8,9.37,34.2,0.0036647999999999997,-0.108936,44.45,1.5317984595421543,10.20213351861658,2.6365979771103797e-11,0.19264399911845514,88.60388821187438,10.07935116710691,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC320TP2M,REC Group,Mono-c-Si,0,320.0,297.5,1.617,,,60.0,10.1,40.0,9.45,33.9,0.00404,-0.1144,44.57,1.540498496039912,10.108755050391265,5.211944054482341e-11,0.1374900074353307,158.61120440519025,8.472899064782242,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC320TP2M BLK,REC Group,Mono-c-Si,0,320.0,297.5,1.617,,,60.0,10.1,40.0,9.45,33.9,0.00404,-0.1144,44.57,1.540498496039912,10.108755050391265,5.211944054482341e-11,0.1374900074353307,158.61120440519025,8.472899064782242,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC320TP3M,REC Group,Mono-c-Si,0,320.0,299.2,1.61,,,60.0,10.32,39.1,9.46,33.8,0.0039216,-0.10322400000000001,44.95,1.4459875941544607,10.329815371245761,1.7669754239915467e-11,0.0686593448273098,72.18926535565325,7.6891071476269754,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC320TP3M Black,REC Group,Mono-c-Si,0,320.0,299.2,1.61,,,60.0,10.32,39.1,9.46,33.8,0.0039216,-0.10322400000000001,44.95,1.4459875941544607,10.329815371245761,1.7669754239915467e-11,0.0686593448273098,72.18926535565325,7.6891071476269754,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325NP,REC Group,Mono-c-Si,0,325.0,304.0,1.62,,,60.0,10.27,41.0,9.46,34.4,0.004108,-0.10906000000000002,44.11,1.5438015835091223,10.291287089974235,2.8770403050726742e-11,0.18703682972708616,90.2363005011675,11.140242816814991,-0.351,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325NP Black,REC Group,Mono-c-Si,0,325.0,303.5,1.62,,,60.0,10.28,40.7,9.46,34.4,0.0037007999999999997,-0.10866900000000002,44.45,1.5348900723396506,10.29852808446033,2.995300500496948e-11,0.15567252812278753,86.37231750968341,11.135733114249856,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325TP2M,REC Group,Mono-c-Si,0,325.0,302.3,1.617,,,60.0,10.12,40.4,9.56,34.0,0.004048,-0.11554399999999998,44.57,1.5425520793032328,10.125537549219679,4.221347989825485e-11,0.16931317534741785,309.423769817766,6.58500668006827,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325TP2M BLK,REC Group,Mono-c-Si,0,325.0,302.3,1.617,,,60.0,10.12,40.4,9.56,34.0,0.004048,-0.11554399999999998,44.57,1.5425520793032328,10.125537549219679,4.221347989825485e-11,0.16931317534741785,309.423769817766,6.58500668006827,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325TP2S 72,REC Group,Multi-c-Si,0,325.0,295.5,1.95,2.005,1.001,72.0,9.19,45.9,8.56,38.0,0.004595,-0.16065,44.26,1.9628177978872874,9.200010080411447,6.280520387892041e-10,0.24050766069279375,220.80398945828088,8.873708567011514,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325TP2S 72 XV,REC Group,Multi-c-Si,0,325.0,295.5,1.95,2.005,1.001,72.0,9.19,45.9,8.56,38.0,0.004595,-0.16065,44.26,1.9628177978872874,9.200010080411447,6.280520387892041e-10,0.24050766069279375,220.80398945828088,8.873708567011514,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325TP3M,REC Group,Mono-c-Si,0,325.0,304.0,1.61,,,60.0,10.36,39.5,9.54,34.1,0.0039368,-0.10428000000000001,44.95,1.4797168753650796,10.368877739274977,2.522626659583672e-11,0.07015619919975957,81.86974211643985,10.773989886798924,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC325TP3M Black,REC Group,Mono-c-Si,0,325.0,304.0,1.61,,,60.0,10.36,39.5,9.54,34.1,0.0039368,-0.10428000000000001,44.95,1.4797168753650796,10.368877739274977,2.522626659583672e-11,0.07015619919975957,81.86974211643985,10.773989886798924,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330NP,REC Group,Mono-c-Si,0,330.0,309.2,1.61,,,60.0,10.33,41.0,9.55,34.6,0.0037188,-0.10783000000000001,44.26,1.5220592249700318,10.347874545587434,1.986440969846512e-11,0.16793545999270962,97.052722114456,9.093119730974221,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330NP Black,REC Group,Mono-c-Si,0,330.0,308.3,1.62,,,60.0,10.33,41.0,9.55,34.6,0.0037188,-0.10947000000000001,44.45,1.5412275931111217,10.347146700256308,2.7784509682476414e-11,0.16341039296918802,98.44630976117665,10.39917384485465,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330TP2M,REC Group,Mono-c-Si,0,330.0,307.1,1.617,,,60.0,10.22,40.6,9.62,34.3,0.0040880000000000005,-0.116116,44.57,1.5561466034891427,10.226861435241833,4.691215254822719e-11,0.15212980218897007,226.59495306928343,7.427352534726845,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330TP2M BLK,REC Group,Mono-c-Si,0,330.0,307.1,1.617,,,60.0,10.22,40.6,9.62,34.3,0.0040880000000000005,-0.116116,44.57,1.5561466034891427,10.226861435241833,4.691215254822719e-11,0.15212980218897007,226.59495306928343,7.427352534726845,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330TP2S 72,REC Group,Multi-c-Si,0,330.0,300.2,1.95,2.005,1.001,72.0,9.44,46.0,8.67,38.1,0.00472,-0.161,44.26,1.9835753482679053,9.457654023167592,7.703318367566678e-10,0.22874512147250495,122.31512963475468,10.499411851916076,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330TP2S 72 XV,REC Group,Multi-c-Si,0,330.0,300.2,1.95,2.005,1.001,72.0,9.44,46.0,8.67,38.1,0.00472,-0.161,44.26,1.9835753482679053,9.457654023167592,7.703318367566678e-10,0.22874512147250495,122.31512963475468,10.499411851916076,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330TP3M,REC Group,Mono-c-Si,0,330.0,308.8,1.61,,,60.0,10.39,39.9,9.62,34.3,0.0039482,-0.10533600000000001,44.95,1.4871409463017626,10.399713477585001,2.2239616447173894e-11,0.08946355050912817,95.69449082512132,9.599175800458559,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC330TP3M Black,REC Group,Mono-c-Si,0,330.0,308.8,1.61,,,60.0,10.39,39.9,9.62,34.3,0.0039482,-0.10533600000000001,44.95,1.4871409463017626,10.399713477585001,2.2239616447173894e-11,0.08946355050912817,95.69449082512132,9.599175800458559,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC335NP,REC Group,Mono-c-Si,0,335.0,314.0,1.61,,,60.0,10.38,41.3,9.64,34.8,0.0037367999999999998,-0.108619,44.26,1.528441743341646,10.396209274407815,1.8457675110748203e-11,0.17545112311215424,112.35436064797888,8.383421505623886,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC335TP2S 72,REC Group,Multi-c-Si,0,335.0,304.9,1.95,2.005,1.001,72.0,9.52,46.2,8.75,38.3,0.00476,-0.1617,44.26,1.9924054887702367,9.537085311308251,7.793484639938904e-10,0.22336545405102057,124.46008557981192,10.525734575718838,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC335TP2S 72 XV,REC Group,Multi-c-Si,0,335.0,304.9,1.95,2.005,1.001,72.0,9.52,46.2,8.75,38.3,0.00476,-0.1617,44.26,1.9924054887702367,9.537085311308251,7.793484639938904e-10,0.22336545405102057,124.46008557981192,10.525734575718838,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC335TP3M,REC Group,Mono-c-Si,0,335.0,313.6,1.61,,,60.0,10.42,40.2,9.69,34.6,0.0039596,-0.10612800000000001,44.95,1.4958540890062284,10.428154454993225,2.1445910227411572e-11,0.08597992018490098,109.86764554847102,9.232692978209176,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC335TP3M Black,REC Group,Mono-c-Si,0,335.0,313.6,1.61,,,60.0,10.42,40.2,9.69,34.6,0.0039596,-0.10612800000000001,44.95,1.4958540890062284,10.428154454993225,2.1445910227411572e-11,0.08597992018490098,109.86764554847102,9.232692978209176,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC340AA,REC Group,Mono-c-Si,0,340.0,322.7,1.68,,,60.0,10.09,43.1,9.34,36.4,0.0037333,-0.103871,44.01,1.4759174508560406,10.111115713584702,2.0109951355958874e-12,0.20791933339247473,99.35283761531333,-1.025396392331917,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC340AA Black,REC Group,Mono-c-Si,0,340.0,321.0,1.69,,,60.0,10.09,43.1,9.34,36.4,0.0038342,-0.10344,45.55,1.4831519943365266,10.110830745114313,2.319291143134661e-12,0.20611808426528683,99.83951411879633,0.5520379614289581,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC340TP2S 72,REC Group,Multi-c-Si,0,340.0,309.6,1.95,2.005,1.001,72.0,9.58,46.3,8.84,38.5,0.00479,-0.16204999999999997,44.26,1.9957679380510027,9.594175983391224,7.790905914643906e-10,0.20785401665269496,140.4658577783529,10.453511157175642,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC340TP2S 72 XV,REC Group,Multi-c-Si,0,340.0,309.6,1.95,2.005,1.001,72.0,9.58,46.3,8.84,38.5,0.00479,-0.16204999999999997,44.26,1.9957679380510027,9.594175983391224,7.790905914643906e-10,0.20785401665269496,140.4658577783529,10.453511157175642,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC340TP3M,REC Group,Mono-c-Si,0,340.0,318.4,1.61,,,60.0,10.45,40.6,9.79,34.7,0.003971,-0.10718400000000002,44.95,1.4996687366693862,10.45820686620709,1.78025891705937e-11,0.11693413333673171,148.89504298708323,7.537710590591918,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC340TP3M Black,REC Group,Mono-c-Si,0,340.0,318.4,1.61,,,60.0,10.45,40.6,9.79,34.7,0.003971,-0.10718400000000002,44.95,1.4996687366693862,10.45820686620709,1.78025891705937e-11,0.11693413333673171,148.89504298708323,7.537710590591918,-0.336,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC345AA,REC Group,Mono-c-Si,0,345.0,327.5,1.68,,,60.0,10.12,43.4,9.39,36.7,0.0037443999999999997,-0.10459399999999999,44.01,1.4854271299558341,10.139315818319954,1.9922366571629423e-12,0.2033861254795476,106.5586534515435,-1.1364720300205409,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC345AA Black,REC Group,Mono-c-Si,0,345.0,325.8,1.69,,,60.0,10.12,43.4,9.39,36.7,0.0038456,-0.10415999999999999,45.55,1.4927061903322778,10.139044904060373,2.2977333873707547e-12,0.20158285143499133,107.11623621553984,0.4397291579784201,-0.282,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC345NP2,REC Group,Mono-c-Si,0,345.0,324.5,1.77,,,60.0,11.19,40.4,10.54,32.7,0.0040284,-0.101808,43.93,1.4204631973706627,11.205912376252936,4.901794111953407e-12,0.3145168756728469,221.17651114840382,0.876762008100138,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC345NP2 Black,REC Group,Mono-c-Si,0,345.0,324.5,1.77,,,60.0,11.19,40.4,10.54,32.7,0.0040284,-0.101808,43.93,1.4204631973706627,11.205912376252936,4.901794111953407e-12,0.3145168756728469,221.17651114840382,0.876762008100138,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC345TP2S 72,REC Group,Multi-c-Si,0,345.0,314.3,1.95,2.005,1.001,72.0,9.64,46.5,8.92,38.7,0.004820000000000001,-0.16275,44.26,2.0022209063131355,9.65267028641993,7.669941755557426e-10,0.20376665498037472,155.0328609072317,10.248131327416798,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC345TP2S 72 XV,REC Group,Multi-c-Si,0,345.0,314.3,1.95,2.005,1.001,72.0,9.64,46.5,8.92,38.7,0.004820000000000001,-0.16275,44.26,2.0022209063131355,9.65267028641993,7.669941755557426e-10,0.20376665498037472,155.0328609072317,10.248131327416798,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC350AA,REC Group,Mono-c-Si,0,350.0,332.4,1.68,,,60.0,10.16,43.8,9.45,37.1,0.0037592000000000003,-0.105558,44.01,1.4985939917651416,10.1774181192991,1.9851418756991437e-12,0.19733212074802373,115.1039508349466,-1.2080945687754976,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC350AA Black,REC Group,Mono-c-Si,0,350.0,331.3,1.69,,,60.0,10.44,43.2,9.73,36.0,0.0038627999999999996,-0.10152000000000001,46.01,1.4395445985237625,10.46340192481251,9.359849961150825e-13,0.26483705733320745,118.14835323904573,-5.048402452113424,-0.266,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC350NP2,REC Group,Mono-c-Si,0,350.0,329.3,1.77,,,60.0,11.22,40.6,10.57,33.1,0.0040392,-0.10231200000000001,43.93,1.4324183279586598,11.235058805855969,5.4166748038630834e-12,0.28937066789087895,215.60400921625157,1.6853906149207978,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC350NP2 Black,REC Group,Mono-c-Si,0,350.0,329.3,1.77,,,60.0,11.22,40.6,10.57,33.1,0.0040392,-0.10231200000000001,43.93,1.4324183279586598,11.235058805855969,5.4166748038630834e-12,0.28937066789087895,215.60400921625157,1.6853906149207978,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC350TP2S 72,REC Group,Multi-c-Si,0,350.0,319.0,1.95,2.005,1.001,72.0,9.72,46.7,9.0,38.9,0.004860000000000001,-0.16345,44.26,2.01109285823979,9.732211550400596,7.762344556131516e-10,0.19874500605173764,158.19462668892143,10.279157567447193,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC350TP2S 72 XV,REC Group,Multi-c-Si,0,350.0,319.0,1.95,2.005,1.001,72.0,9.72,46.7,9.0,38.9,0.004860000000000001,-0.16345,44.26,2.01109285823979,9.732211550400596,7.762344556131516e-10,0.19874500605173764,158.19462668892143,10.279157567447193,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC350TP4 Black,REC Group,Mono-c-Si,0,350.0,326.4,1.77,,,60.0,11.1,40.3,10.58,33.3,0.0041069999999999995,-0.107198,45.51,1.45322355385162,11.100005512187224,1.0039291421031215e-11,0.23555321853332026,474342.5146678758,1.2961468247549095,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355AA,REC Group,Mono-c-Si,0,355.0,337.2,1.68,,,60.0,10.19,44.0,9.5,37.4,0.0037702999999999994,-0.10604,44.01,1.5062901597473632,10.205003795047274,2.0291681726698925e-12,0.18235558374405506,123.84888705314839,-1.061724887987495,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355AA Black,REC Group,Mono-c-Si,0,355.0,336.2,1.69,,,60.0,10.47,43.6,9.77,36.4,0.0038739000000000004,-0.10246,46.01,1.4533078020648154,10.491887440888874,9.483377626033785e-13,0.2588200525101582,123.80825895030388,-4.971562961017335,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355NP2,REC Group,Mono-c-Si,0,355.0,334.1,1.77,,,60.0,11.27,40.7,10.6,33.5,0.0040571999999999995,-0.102564,43.93,1.4437236135214684,11.285573091603078,6.3203376220737984e-12,0.25441011443877437,184.11257255446202,2.950500828390202,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355NP2 Black,REC Group,Mono-c-Si,0,355.0,334.1,1.77,,,60.0,11.27,40.7,10.6,33.5,0.0040571999999999995,-0.102564,43.93,1.4437236135214684,11.285573091603078,6.3203376220737984e-12,0.25441011443877437,184.11257255446202,2.950500828390202,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355TP2S 72,REC Group,Multi-c-Si,0,355.0,323.7,1.95,2.005,1.001,72.0,9.78,46.8,9.09,39.1,0.00489,-0.16379999999999997,44.26,2.014563340928593,9.78976725533193,7.76821100583498e-10,0.18387332915626944,184.1132749191387,10.218044387235892,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355TP2S 72 XV,REC Group,Multi-c-Si,0,355.0,323.7,1.95,2.005,1.001,72.0,9.78,46.8,9.09,39.1,0.00489,-0.16379999999999997,44.26,2.014563340928593,9.78976725533193,7.76821100583498e-10,0.18387332915626944,184.1132749191387,10.218044387235892,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355TP4,REC Group,Mono-c-Si,0,355.0,331.2,1.77,,,60.0,11.19,40.5,10.6,33.5,0.0041402999999999995,-0.10773,45.51,1.4677536992870526,11.197199108826158,1.1511539599840006e-11,0.23043963516653607,358.18593655956107,2.3980456334916056,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC355TP4 Black,REC Group,Mono-c-Si,0,355.0,331.2,1.77,,,60.0,11.19,40.5,10.6,33.5,0.0041402999999999995,-0.10773,45.51,1.4677536992870526,11.197199108826158,1.1511539599840006e-11,0.23043963516653607,358.18593655956107,2.3980456334916056,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360AA,REC Group,Mono-c-Si,0,360.0,342.1,1.68,,,60.0,10.23,44.1,9.55,37.7,0.0037851,-0.106281,44.01,1.512864631760162,10.242483854052846,2.1672731525245133e-12,0.1567323234071443,128.4356304973883,-0.5571983035540664,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360AA Black,REC Group,Mono-c-Si,0,360.0,341.0,1.69,,,60.0,10.49,43.9,9.82,36.7,0.0038813000000000003,-0.10316499999999999,46.01,1.462132658478087,10.509046107520632,9.308719016085484e-13,0.2544941859738255,140.16743360848835,-5.1482906772310715,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360NP2,REC Group,Mono-c-Si,0,360.0,338.9,1.77,,,60.0,11.31,40.8,10.62,33.9,0.0040716,-0.10281599999999999,43.93,1.4550914202423606,11.325434114802945,7.35943331414172e-12,0.21986261284814268,161.11362319270899,4.21943511797526,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360NP2 Black,REC Group,Mono-c-Si,0,360.0,338.9,1.77,,,60.0,11.31,40.8,10.62,33.9,0.0040716,-0.10281599999999999,43.93,1.4550914202423606,11.325434114802945,7.35943331414172e-12,0.21986261284814268,161.11362319270899,4.21943511797526,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360TP2SM 72,REC Group,Mono-c-Si,0,360.0,337.9,1.947,2.005,1.001,72.0,9.74,47.4,9.14,39.4,0.0037012,-0.13509,41.94,1.7919970011264004,9.7509933400223,3.1091250868539556e-11,0.27004167340618834,239.25448663099195,4.72865925815536,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360TP2SM 72 BLK,REC Group,Mono-c-Si,0,360.0,337.9,1.947,2.005,1.001,72.0,9.74,47.4,9.14,39.4,0.0037012,-0.13509,41.94,1.7919970011264004,9.7509933400223,3.1091250868539556e-11,0.27004167340618834,239.25448663099195,4.72865925815536,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360TP2SM 72 XV,REC Group,Mono-c-Si,0,360.0,337.9,1.947,,,72.0,9.74,47.4,9.14,39.4,0.0037012,-0.13509,41.94,1.7919970011264004,9.7509933400223,3.1091250868539556e-11,0.27004167340618834,239.25448663099195,4.72865925815536,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,360.0,337.9,1.947,,,72.0,9.74,47.4,9.14,39.4,0.0037012,-0.13509,41.94,1.7919970011264004,9.7509933400223,3.1091250868539556e-11,0.27004167340618834,239.25448663099195,4.72865925815536,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360TP4,REC Group,Mono-c-Si,0,360.0,336.0,1.77,,,60.0,11.26,40.6,10.62,33.9,0.0041662,-0.10799600000000001,45.51,1.4813675321372088,11.269913382049591,1.3869073574453409e-11,0.1951233986368534,221.62864985217763,3.929393096280869,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC360TP4 Black,REC Group,Mono-c-Si,0,360.0,336.0,1.77,,,60.0,11.26,40.6,10.62,33.9,0.0041662,-0.10799600000000001,45.51,1.4813675321372088,11.269913382049591,1.3869073574453409e-11,0.1951233986368534,221.62864985217763,3.929393096280869,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365AA,REC Group,Mono-c-Si,0,365.0,346.9,1.68,,,60.0,10.26,44.3,9.6,38.0,0.0037961999999999996,-0.106763,44.01,1.520524101882454,10.270484615615034,2.2124640022379965e-12,0.14215654780655151,139.1110776514638,-0.4206006468202583,-0.279,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365AA Black,REC Group,Mono-c-Si,0,365.0,345.9,1.69,,,60.0,10.52,44.0,9.85,37.1,0.0038924,-0.10339999999999999,46.01,1.4711483831092451,10.536507531875674,1.0478478039991008e-12,0.21798817139590532,138.92055946857909,-4.223702712035045,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365NP 72,REC Group,Mono-c-Si,0,365.0,340.7,1.947,,,72.0,10.12,47.4,9.35,39.1,0.0031371999999999997,-0.126084,44.37,1.743386692986804,10.146875764756182,1.5159530149083433e-11,0.3081112000814372,116.01847794828203,5.758258375386507,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365NP 72 XV,REC Group,Mono-c-Si,0,365.0,340.7,1.947,,,72.0,10.12,47.4,9.35,39.1,0.0031371999999999997,-0.126084,44.37,1.743386692986804,10.146875764756182,1.5159530149083433e-11,0.3081112000814372,116.01847794828203,5.758258375386507,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365NP2,REC Group,Mono-c-Si,0,365.0,343.7,1.77,,,60.0,11.36,40.9,10.65,34.3,0.0040896,-0.10306799999999999,43.93,1.4664442912337652,11.374604628301713,8.555285295906359e-12,0.18530797039015157,144.13913891484606,5.480112096752842,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365NP2 Black,REC Group,Mono-c-Si,0,365.0,343.7,1.77,,,60.0,11.36,40.9,10.65,34.3,0.0040896,-0.10306799999999999,43.93,1.4664442912337652,11.374604628301713,8.555285295906359e-12,0.18530797039015157,144.13913891484606,5.480112096752842,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365TP2SM 72,REC Group,Mono-c-Si,0,365.0,342.7,1.947,2.005,1.001,72.0,9.82,47.6,9.22,39.6,0.0037316000000000003,-0.13566,41.94,1.799879647881688,9.83059779123645,3.1512296764899596e-11,0.264811746335804,245.37673094038863,4.771297939598877,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365TP2SM 72 BLK,REC Group,Mono-c-Si,0,365.0,342.7,1.947,2.005,1.001,72.0,9.82,47.6,9.22,39.6,0.0037316000000000003,-0.13566,41.94,1.799879647881688,9.83059779123645,3.1512296764899596e-11,0.264811746335804,245.37673094038863,4.771297939598877,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365TP2SM 72 XV,REC Group,Mono-c-Si,0,365.0,342.7,1.947,,,72.0,9.82,47.6,9.22,39.6,0.0037316000000000003,-0.13566,41.94,1.799879647881688,9.83059779123645,3.1512296764899596e-11,0.264811746335804,245.37673094038863,4.771297939598877,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,365.0,342.7,1.947,,,72.0,9.82,47.6,9.22,39.6,0.0037316000000000003,-0.13566,41.94,1.799879647881688,9.83059779123645,3.1512296764899596e-11,0.264811746335804,245.37673094038863,4.771297939598877,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365TP4,REC Group,Mono-c-Si,0,365.0,340.8,1.77,,,60.0,11.32,40.8,10.65,34.3,0.0041884,-0.108528,45.51,1.4955851012525034,11.330568105505673,1.5771895215833943e-11,0.16974966038445827,181.82692839477963,4.987417872382645,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC365TP4 Black,REC Group,Mono-c-Si,0,365.0,340.8,1.77,,,60.0,11.32,40.8,10.65,34.3,0.0041884,-0.108528,45.51,1.4955851012525034,11.330568105505673,1.5771895215833943e-11,0.16974966038445827,181.82692839477963,4.987417872382645,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370AA,REC Group,Mono-c-Si,0,370.0,351.8,1.69,,,60.0,10.55,44.1,9.9,37.4,0.0035870000000000008,-0.104076,45.45,1.4558544636204112,10.56421746917012,7.176598917418039e-13,0.19840695021303775,147.22685825319022,-7.5929458593915875,-0.258,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370AA Black,REC Group,Mono-c-Si,0,370.0,350.7,1.69,,,60.0,10.55,44.1,9.9,37.4,0.0039035000000000003,-0.10363499999999999,46.01,1.476955361090079,10.56356261518235,1.1069046599209532e-12,0.19340286540068147,150.44297889234096,-3.8142090020771042,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370NP 72,REC Group,Mono-c-Si,0,370.0,345.5,1.947,,,72.0,10.16,47.7,9.42,39.3,0.0031496000000000002,-0.12688200000000002,44.37,1.7502754046817337,10.18453904391025,1.433141714750586e-11,0.31489940142821565,130.37907832337606,5.229086493114187,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370NP 72 XV,REC Group,Mono-c-Si,0,370.0,345.5,1.947,,,72.0,10.16,47.7,9.42,39.3,0.0031496000000000002,-0.12688200000000002,44.37,1.7502754046817337,10.18453904391025,1.433141714750586e-11,0.31489940142821565,130.37907832337606,5.229086493114187,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370NP2,REC Group,Mono-c-Si,0,370.0,348.5,1.77,,,60.0,11.41,41.1,10.68,34.7,0.0041076,-0.10357200000000001,43.93,1.4796382612754515,11.423873111458759,9.602415560848829e-12,0.16038993973199286,131.91339375286157,6.448741512001659,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370NP2 Black,REC Group,Mono-c-Si,0,370.0,348.5,1.77,,,60.0,11.41,41.1,10.68,34.7,0.0041076,-0.10357200000000001,43.93,1.4796382612754515,11.423873111458759,9.602415560848829e-12,0.16038993973199286,131.91339375286157,6.448741512001659,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370TP2SM 72,REC Group,Mono-c-Si,0,370.0,347.5,1.947,2.005,1.001,72.0,9.85,47.8,9.3,39.8,0.0037430000000000002,-0.13623,41.94,1.8032072438182414,9.856890776324478,2.989878990397695e-11,0.2616433047781514,374.0052595261984,4.279032603848888,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370TP2SM 72 BLK,REC Group,Mono-c-Si,0,370.0,347.5,1.947,2.005,1.001,72.0,9.85,47.8,9.3,39.8,0.0037430000000000002,-0.13623,41.94,1.8032072438182414,9.856890776324478,2.989878990397695e-11,0.2616433047781514,374.0052595261984,4.279032603848888,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370TP2SM 72 XV,REC Group,Mono-c-Si,0,370.0,347.5,1.947,,,72.0,9.85,47.8,9.3,39.8,0.0037430000000000002,-0.13623,41.94,1.8032072438182414,9.856890776324478,2.989878990397695e-11,0.2616433047781514,374.0052595261984,4.279032603848888,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,370.0,347.5,1.947,,,72.0,9.85,47.8,9.3,39.8,0.0037430000000000002,-0.13623,41.94,1.8032072438182414,9.856890776324478,2.989878990397695e-11,0.2616433047781514,374.0052595261984,4.279032603848888,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC370TP4,REC Group,Mono-c-Si,0,370.0,345.6,1.77,,,60.0,11.38,41.0,10.68,34.7,0.0042106,-0.10906000000000002,45.51,1.5098563193597487,11.390619192472819,1.7910597363503882e-11,0.14451130190736686,154.86475317147287,6.04326122823496,-0.339,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC370TP4 Black,REC Group,Mono-c-Si,0,370.0,345.6,1.77,,,60.0,11.38,41.0,10.68,34.7,0.0042106,-0.10906000000000002,45.51,1.5098563193597487,11.390619192472819,1.7910597363503882e-11,0.14451130190736686,154.86475317147287,6.04326122823496,-0.339,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC375AA,REC Group,Mono-c-Si,0,375.0,356.6,1.69,,,60.0,10.58,44.2,9.94,37.8,0.0035972000000000005,-0.104312,45.45,1.46394722244518,10.591296345078726,7.952743976027231e-13,0.16265564756560133,152.34102416061495,-6.816155459623674,-0.258,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375AA Black,REC Group,Mono-c-Si,0,375.0,355.6,1.69,,,60.0,10.58,44.2,9.94,37.8,0.0039146,-0.10387,46.01,1.48522507545258,10.590707725692914,1.2263378672979371e-12,0.15760193218274446,155.7219982416896,-3.012707171954378,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375NP 72,REC Group,Mono-c-Si,0,375.0,350.3,1.947,,,72.0,10.2,48.1,9.46,39.7,0.003162,-0.127946,44.37,1.7662971403372578,10.223792223834637,1.4692170248261396e-11,0.30772935558348136,131.92711440145047,5.407020453319134,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375NP 72 XV,REC Group,Mono-c-Si,0,375.0,350.3,1.947,,,72.0,10.2,48.1,9.46,39.7,0.003162,-0.127946,44.37,1.7662971403372578,10.223792223834637,1.4692170248261396e-11,0.30772935558348136,131.92711440145047,5.407020453319134,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375NP2,REC Group,Mono-c-Si,0,375.0,353.4,1.77,,,60.0,11.46,41.3,10.72,35.0,0.0041256,-0.104076,43.93,1.4900651367286233,11.473170614233076,1.0231389363289769e-11,0.14641205265128326,127.39589030597554,6.9662324638518,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375NP2 Black,REC Group,Mono-c-Si,0,375.0,353.4,1.77,,,60.0,11.46,41.3,10.72,35.0,0.0041256,-0.104076,43.93,1.4900651367286233,11.473170614233076,1.0231389363289769e-11,0.14641205265128326,127.39589030597554,6.9662324638518,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375TP2SM 72,REC Group,Mono-c-Si,0,375.0,352.3,1.947,2.005,1.001,72.0,9.96,48.0,9.36,40.1,0.0037848,-0.13679999999999998,41.94,1.8181446292163255,9.96951881061991,3.347767807129621e-11,0.24278426002653136,254.0371216401887,5.1614930288516705,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375TP2SM 72 BLK,REC Group,Mono-c-Si,0,375.0,352.3,1.947,2.005,1.001,72.0,9.96,48.0,9.36,40.1,0.0037848,-0.13679999999999998,41.94,1.8181446292163255,9.96951881061991,3.347767807129621e-11,0.24278426002653136,254.0371216401887,5.1614930288516705,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375TP2SM 72 XV,REC Group,Mono-c-Si,0,375.0,352.3,1.947,,,72.0,9.96,48.0,9.36,40.1,0.0037848,-0.13679999999999998,41.94,1.8181446292163255,9.96951881061991,3.347767807129621e-11,0.24278426002653136,254.0371216401887,5.1614930288516705,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,375.0,352.3,1.947,,,72.0,9.96,48.0,9.36,40.1,0.0037848,-0.13679999999999998,41.94,1.8181446292163255,9.96951881061991,3.347767807129621e-11,0.24278426002653136,254.0371216401887,5.1614930288516705,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375TP4,REC Group,Mono-c-Si,0,375.0,350.4,1.77,,,60.0,11.45,41.2,10.72,35.0,0.0042365,-0.10959200000000001,45.51,1.5219250853038468,11.460902869582736,1.9536812905827636e-11,0.12999829446612643,136.52190047237713,6.751497509316373,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC375TP4 Black,REC Group,Mono-c-Si,0,375.0,350.4,1.77,,,60.0,11.45,41.2,10.72,35.0,0.0042365,-0.10959200000000001,45.51,1.5219250853038468,11.460902869582736,1.9536812905827636e-11,0.12999829446612643,136.52190047237713,6.751497509316373,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380AA,REC Group,Mono-c-Si,0,380.0,361.5,1.69,,,60.0,10.61,44.3,9.98,38.1,0.0036074,-0.104548,45.45,1.4702461593134648,10.619265466768146,8.487674874096008e-13,0.13851720578579954,158.61775669364167,-6.331068052068198,-0.258,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380AA Black,REC Group,Mono-c-Si,0,380.0,360.4,1.69,,,60.0,10.61,44.3,9.98,38.1,0.0039257,-0.10410499999999999,46.01,1.4916519061949656,10.618726137189318,1.3086185339449788e-12,0.13343526442512835,162.24225280302377,-2.512250838741042,-0.266,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380AA Pure,REC Group,Mono-c-Si,0,380.0,361.6,1.79,,,66.0,10.17,48.4,9.3,40.9,0.0034578,-0.112772,45.01,1.609056836213725,10.20038049164535,8.296933217097795e-13,0.2417857260996772,80.93879915983909,-4.840837969825749,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380NP 72,REC Group,Mono-c-Si,0,380.0,355.1,1.947,,,72.0,10.24,48.5,9.56,39.8,0.0031744,-0.12901,44.37,1.7700315957417583,10.259857193390216,1.2566831369030959e-11,0.33723787808704525,173.9075381975996,4.017260982766509,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380NP 72 XV,REC Group,Mono-c-Si,0,380.0,355.1,1.947,,,72.0,10.24,48.5,9.56,39.8,0.0031744,-0.12901,44.37,1.7700315957417583,10.259857193390216,1.2566831369030959e-11,0.33723787808704525,173.9075381975996,4.017260982766509,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380NP2,REC Group,Mono-c-Si,0,380.0,358.2,1.77,,,60.0,11.51,41.4,10.77,35.3,0.0041436,-0.10432799999999999,43.93,1.4979873643793684,11.52116478596446,1.1127953159121922e-11,0.12335194888591039,127.165978678975,7.662541711878767,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380NP2 Black,REC Group,Mono-c-Si,0,380.0,358.2,1.77,,,60.0,11.51,41.4,10.77,35.3,0.0041436,-0.10432799999999999,43.93,1.4979873643793684,11.52116478596446,1.1127953159121922e-11,0.12335194888591039,127.165978678975,7.662541711878767,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380NP3 Black,REC Group,Mono-c-Si,0,380.0,354.4,1.92,,,66.0,11.22,44.5,10.56,36.0,0.004488000000000001,-0.11525500000000001,46.61,1.5715902107364539,11.236682789351697,5.572137419486002e-12,0.3461637454980514,232.8122205650975,-0.9045877293272155,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380TP2SM 72,REC Group,Mono-c-Si,0,380.0,357.1,1.947,2.005,1.001,72.0,10.05,48.2,9.43,40.3,0.0038190000000000003,-0.13737,41.94,1.827927696145393,10.06040175322997,3.4808334925897415e-11,0.23734972789866707,229.32333940040618,5.422976321463864,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380TP2SM 72 BLK,REC Group,Mono-c-Si,0,380.0,357.1,1.947,2.005,1.001,72.0,10.05,48.2,9.43,40.3,0.0038190000000000003,-0.13737,41.94,1.827927696145393,10.06040175322997,3.4808334925897415e-11,0.23734972789866707,229.32333940040618,5.422976321463864,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380TP2SM 72 XV,REC Group,Mono-c-Si,0,380.0,357.1,1.947,,,72.0,10.05,48.2,9.43,40.3,0.0038190000000000003,-0.13737,41.94,1.827927696145393,10.06040175322997,3.4808334925897415e-11,0.23734972789866707,229.32333940040618,5.422976321463864,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,380.0,357.1,1.947,,,72.0,10.05,48.2,9.43,40.3,0.0038190000000000003,-0.13737,41.94,1.827927696145393,10.06040175322997,3.4808334925897415e-11,0.23734972789866707,229.32333940040618,5.422976321463864,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC380TP3SM 72 XV,REC Group,Mono-c-Si,0,380.0,355.0,1.95,,,72.0,10.3,46.9,9.41,40.4,0.0033990000000000005,-0.12428499999999999,44.81,1.7635567867465758,10.311508666251394,2.7473493155435276e-11,0.09160415498628693,81.98367885053399,11.271471153002881,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385AA,REC Group,Mono-c-Si,0,385.0,366.4,1.69,,,60.0,10.64,44.4,10.03,38.4,0.0036176000000000008,-0.104784,45.45,1.4758520661868322,10.647044975545562,8.937201342894904e-13,0.11478063457326164,173.3527595898219,-5.954982992872557,-0.258,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385AA Pure,REC Group,Mono-c-Si,0,385.0,366.5,1.794,,,66.0,10.1,48.5,9.35,41.2,0.003434,-0.11300500000000001,45.01,1.60709945683536,10.120573458091968,7.56897012787481e-13,0.2193330642696692,107.67581474516176,-5.568970227545739,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385AA Pure-P,REC Group,Mono-c-Si,0,385.0,367.3,1.79,,,66.0,10.18,48.5,9.35,41.2,0.0037665999999999997,-0.111065,44.03,1.620625525462393,10.204579967906106,9.725584591195402e-13,0.21456619576077862,88.86439076856571,-1.947809789750643,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385NP 72,REC Group,Mono-c-Si,0,385.0,359.9,1.947,,,72.0,10.28,48.9,9.63,40.0,0.0031868,-0.130074,44.37,1.7788437076716315,10.297423183127583,1.1590163955350925e-11,0.3541193318175287,208.9369503106315,3.2884501866993356,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385NP 72 XV,REC Group,Mono-c-Si,0,385.0,359.9,1.947,,,72.0,10.28,48.9,9.63,40.0,0.0031868,-0.130074,44.37,1.7788437076716315,10.297423183127583,1.1590163955350925e-11,0.3541193318175287,208.9369503106315,3.2884501866993356,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385TP2SM 72,REC Group,Mono-c-Si,0,385.0,361.9,1.947,,,72.0,10.1,48.4,9.51,40.5,0.003838,-0.13793999999999998,41.94,1.8330649122284763,10.108245095143854,3.390766475863251e-11,0.2337213428401619,286.301800885837,5.143730550740174,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385TP2SM 72 BLK,REC Group,Mono-c-Si,0,385.0,361.9,1.947,,,72.0,10.1,48.4,9.51,40.5,0.003838,-0.13793999999999998,41.94,1.8330649122284763,10.108245095143854,3.390766475863251e-11,0.2337213428401619,286.301800885837,5.143730550740174,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,385.0,361.9,1.947,,,72.0,10.1,48.4,9.51,40.5,0.003838,-0.13793999999999998,41.94,1.8330649122284763,10.108245095143854,3.390766475863251e-11,0.2337213428401619,286.301800885837,5.143730550740174,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC385TP3SM 72 XV,REC Group,Mono-c-Si,0,385.0,359.8,1.95,,,72.0,10.33,47.2,9.47,40.7,0.0034089000000000003,-0.12508000000000002,44.81,1.7013043951031,10.330024624037202,9.230869460171584e-12,0.10483467480665071,43979.082029548255,1.6355959919135359,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390AA Pure,REC Group,Mono-c-Si,0,390.0,371.3,1.79,,,66.0,10.19,48.6,9.4,41.5,0.0034646,-0.11323800000000002,45.01,1.6169631534247755,10.209996253969393,8.590207025570168e-13,0.1914992101326142,97.58712579038371,-4.613568890780696,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390AA Pure-P,REC Group,Mono-c-Si,0,390.0,372.2,1.79,,,66.0,10.19,48.6,9.4,41.5,0.0037702999999999994,-0.11129400000000002,44.03,1.6245871978276247,10.209718834890623,9.893158326403166e-13,0.189572284265497,97.96426704117543,-1.833168008906933,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390NP 72,REC Group,Mono-c-Si,0,390.0,364.6,1.947,,,72.0,10.32,49.1,9.72,40.2,0.0031992,-0.13060600000000003,44.37,1.7823702447262173,10.332210967579895,1.1050755353096907e-11,0.34988280067042854,295.7006066648858,2.834300468672288,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390NP 72 XV,REC Group,Mono-c-Si,0,390.0,364.6,1.947,,,72.0,10.32,49.1,9.72,40.2,0.0031992,-0.13060600000000003,44.37,1.7823702447262173,10.332210967579895,1.1050755353096907e-11,0.34988280067042854,295.7006066648858,2.834300468672288,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390NP3 Black,REC Group,Mono-c-Si,0,390.0,363.9,1.92,,,66.0,11.31,44.8,10.6,36.8,0.004524,-0.116032,46.61,1.597272844969406,11.329258483187894,7.291754843841569e-12,0.2855997738624353,167.72522627491497,1.2574903598430718,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390TP2SM 72,REC Group,Mono-c-Si,0,390.0,366.7,1.947,,,72.0,10.13,48.6,9.58,40.7,0.0038494000000000007,-0.13851,41.94,1.8373888034017845,10.135592199855047,3.26209799115989e-11,0.23073664591030518,417.96829840449277,4.77272386882879,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390TP2SM 72 BLK,REC Group,Mono-c-Si,0,390.0,366.7,1.947,,,72.0,10.13,48.6,9.58,40.7,0.0038494000000000007,-0.13851,41.94,1.8373888034017845,10.135592199855047,3.26209799115989e-11,0.23073664591030518,417.96829840449277,4.77272386882879,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,390.0,366.7,1.947,,,72.0,10.13,48.6,9.58,40.7,0.0038494000000000007,-0.13851,41.94,1.8373888034017845,10.135592199855047,3.26209799115989e-11,0.23073664591030518,417.96829840449277,4.77272386882879,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC390TP3SM 72 XV,REC Group,Mono-c-Si,0,390.0,364.6,1.95,,,72.0,10.35,47.6,9.54,40.9,0.0034155,-0.12614,44.81,1.7790151071920266,10.360988934940599,2.37219521181653e-11,0.10783112208293151,101.56144362868119,9.876202460857417,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395AA Pure,REC Group,Mono-c-Si,0,395.0,376.2,1.794,,,66.0,10.2,48.7,9.45,41.8,0.003468,-0.11347100000000002,45.01,1.6208783068681925,10.215682133644458,8.733404507439666e-13,0.1667985166511364,108.48937421786337,-4.506689639106089,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395AA Pure-P,REC Group,Mono-c-Si,0,395.0,377.1,1.79,,,66.0,10.2,48.7,9.45,41.8,0.0037739999999999996,-0.11152300000000001,44.03,1.6285234408365452,10.215435223647077,1.0058055052280434e-12,0.16487169812891103,108.95153575750018,-1.7231199396197938,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395NP 72,REC Group,Mono-c-Si,0,395.0,369.4,1.947,,,72.0,10.36,49.3,9.77,40.5,0.0032116,-0.131138,44.37,1.7915916675896486,10.370774006421598,1.1446291417239311e-11,0.3339139180772874,321.0828058586003,3.091594371112641,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395NP 72 XV,REC Group,Mono-c-Si,0,395.0,369.4,1.947,,,72.0,10.36,49.3,9.77,40.5,0.0032116,-0.131138,44.37,1.7915916675896486,10.370774006421598,1.1446291417239311e-11,0.3339139180772874,321.0828058586003,3.091594371112641,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395TP2SM 72,REC Group,Mono-c-Si,0,395.0,371.5,1.947,,,72.0,10.17,48.8,9.66,40.9,0.0038645999999999997,-0.13907999999999998,41.94,1.8417107487890554,10.172989694362371,3.1419781521392874e-11,0.22756081683372345,774.0903543365749,4.40436285174719,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395TP2SM 72 BLK,REC Group,Mono-c-Si,0,395.0,371.5,1.947,,,72.0,10.17,48.8,9.66,40.9,0.0038645999999999997,-0.13907999999999998,41.94,1.8417107487890554,10.172989694362371,3.1419781521392874e-11,0.22756081683372345,774.0903543365749,4.40436285174719,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,395.0,371.5,1.947,,,72.0,10.17,48.8,9.66,40.9,0.0038645999999999997,-0.13907999999999998,41.94,1.8417107487890554,10.172989694362371,3.1419781521392874e-11,0.22756081683372345,774.0903543365749,4.40436285174719,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC395TP3SM 72 XV,REC Group,Mono-c-Si,0,395.0,369.4,1.95,,,72.0,10.38,47.9,9.6,41.1,0.0034254000000000003,-0.126935,44.81,1.785739341660197,10.390794272066426,2.2335074070231712e-11,0.11612088553586974,111.66429629026993,9.301329033072463,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400AA Pure,REC Group,Mono-c-Si,0,400.0,381.0,1.794,,,66.0,10.25,48.8,9.51,42.1,0.0034850000000000007,-0.113704,45.01,1.6269449808768717,10.262920924810754,9.24330558587821e-13,0.14120597265275753,112.01684408011619,-4.095537790389961,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400AA Pure 2,REC Group,Mono-c-Si,0,400.0,383.8,1.88,,,66.0,10.6,48.5,9.74,41.1,0.003921999999999999,-0.11397499999999999,43.36,1.5712568928049908,10.628807825772746,3.953321025931841e-13,0.22926146536153985,84.35803354723114,-11.751776938187719,-0.234,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC400AA Pure-P,REC Group,Mono-c-Si,0,400.0,381.9,1.79,,,66.0,10.25,48.8,9.51,42.1,0.0037925000000000003,-0.111752,44.03,1.6346211803781996,10.262689151589031,1.0643236243193571e-12,0.13927749903202657,112.50510762917561,-1.3021630479294266,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400AA Pure-R,REC Group,Mono-c-Si,0,400.0,383.0,1.87,,,80.0,8.73,58.9,8.2,48.8,0.0035793,-0.13841499999999998,45.07,1.8593285774199142,8.7475817101385,1.4867989273530813e-13,0.497133408305239,246.84599052287285,-17.658367278756366,-0.225,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400NP 72,REC Group,Mono-c-Si,0,400.0,374.2,1.947,,,72.0,10.4,49.4,9.84,40.7,0.0032240000000000003,-0.131404,44.37,1.7950573537955956,10.407696212712489,1.1501799066341908e-11,0.31959925653181526,431.87895381483065,3.0864703302838694,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400NP 72 XV,REC Group,Mono-c-Si,0,400.0,374.2,1.947,,,72.0,10.4,49.4,9.84,40.7,0.0032240000000000003,-0.131404,44.37,1.7950573537955956,10.407696212712489,1.1501799066341908e-11,0.31959925653181526,431.87895381483065,3.0864703302838694,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400NP3 Black,REC Group,Mono-c-Si,0,400.0,373.5,1.92,,,66.0,11.39,45.0,10.64,37.6,0.004556,-0.11655,46.61,1.620640651084764,11.407986682276478,9.67278590245761e-12,0.21630139907191512,136.97206089701152,3.5802758896796187,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400TP2SM 72,REC Group,Mono-c-Si,0,400.0,376.3,1.947,,,72.0,10.2,49.0,9.73,41.1,0.0038759999999999997,-0.13965,41.94,1.844718319235847,10.200004812747524,2.969795867606066e-11,0.22492307812395068,476702.8249354219,3.8841462672215674,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400TP2SM 72 BLK,REC Group,Mono-c-Si,0,400.0,376.3,1.947,,,72.0,10.2,49.0,9.73,41.1,0.0038759999999999997,-0.13965,41.94,1.844718319235847,10.200004812747524,2.969795867606066e-11,0.22492307812395068,476702.8249354219,3.8841462672215674,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400TP2SM 72 XV BLK,REC Group,Mono-c-Si,0,400.0,376.3,1.947,,,72.0,10.2,49.0,9.73,41.1,0.0038759999999999997,-0.13965,41.94,1.844718319235847,10.200004812747524,2.969795867606066e-11,0.22492307812395068,476702.8249354219,3.8841462672215674,-0.366,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC400TP3SM 72 XV,REC Group,Mono-c-Si,0,400.0,374.2,1.95,,,72.0,10.42,48.2,9.67,41.4,0.0034386,-0.12773,44.81,1.7946646006370546,10.429464016204296,2.176254795904938e-11,0.11234269626830976,123.69071145547946,9.023157290030914,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC405AA Pure,REC Group,Mono-c-Si,0,405.0,385.9,1.794,,,66.0,10.3,48.9,9.56,42.4,0.0035020000000000003,-0.11393700000000001,45.01,1.633801538552194,10.310597070390518,9.909485342107915e-13,0.11569610409572924,112.45276556539616,-3.574359610973758,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC405AA Pure-P,REC Group,Mono-c-Si,0,405.0,386.8,1.79,,,66.0,10.3,48.9,9.56,42.4,0.003811,-0.111981,44.03,1.641511775089874,10.310375074070347,1.1407178733938134e-12,0.11376278924846654,112.9396013414342,-0.7688847935100733,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC405TP3SM 72 XV,REC Group,Mono-c-Si,0,405.0,379.0,1.95,,,72.0,10.44,48.6,9.72,41.7,0.0034452,-0.12879000000000002,44.81,1.8055495613628691,10.448970385680646,2.0622655267492668e-11,0.11913210707708578,138.64946781329746,8.518080988029173,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC410AA Pure,REC Group,Mono-c-Si,0,410.0,390.8,1.79,,,66.0,10.35,49.0,9.61,42.7,0.003519,-0.11417000000000001,45.01,1.6406469927776397,10.35829355614454,1.0615599010435454e-12,0.0904683379577564,112.90057987626126,-3.056910646427515,-0.256,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC410AA Pure 2,REC Group,Mono-c-Si,0,410.0,393.6,1.88,,,66.0,10.67,48.6,9.86,41.6,0.0039479,-0.11421,43.36,1.5776504564123879,10.690347307401046,4.2574222181949714e-13,0.1813652401858842,95.10679090155624,-11.263440095235522,-0.234,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC410AA Pure-P,REC Group,Mono-c-Si,0,410.0,391.7,1.79,,,66.0,10.35,49.0,9.61,42.7,0.0038294999999999996,-0.11221,44.03,1.6483903721718134,10.358081155115162,1.2216509887314632e-12,0.08853050875863619,113.38611286844036,-0.2395501205744106,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC410AA Pure-R,REC Group,Mono-c-Si,0,410.0,392.7,1.88,,,80.0,8.81,59.2,8.3,49.4,0.0036121000000000005,-0.13912000000000002,45.07,1.8723711165602832,8.824149094160397,1.5984726081580126e-13,0.44723996630669677,278.47606575013157,-17.215168583783633,-0.225,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC410NP3 Black,REC Group,Mono-c-Si,0,410.0,383.1,1.92,,,66.0,11.47,45.2,10.71,38.3,0.004588000000000001,-0.117068,46.61,1.6396665708807066,11.483962918692617,1.1878692731252588e-11,0.1587525058652981,130.40907030359648,5.274508297874943,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC415AA Pure-P,REC Group,Mono-c-Si,0,415.0,396.5,1.79,,,66.0,10.4,49.1,9.67,43.0,0.0038480000000000003,-0.11243900000000001,44.03,1.6544387928240119,10.405671892904179,1.2898478577137775e-12,0.06389248389127362,117.15345190291322,0.16845367557179255,-0.257,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC420AA 72,REC Group,Mono-c-Si,0,420.0,397.9,2.06,,,72.0,10.2,52.5,9.45,44.5,0.002958,-0.123375,45.16,1.7630077765609922,10.220489313339515,1.1421448737156472e-12,0.24049452802335464,119.7231037257681,-3.106276589283335,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC420AA 72 XV,REC Group,Mono-c-Si,0,420.0,397.9,2.06,,,72.0,10.2,52.5,9.45,44.5,0.002958,-0.123375,45.16,1.7630077765609922,10.220489313339515,1.1421448737156472e-12,0.24049452802335464,119.7231037257681,-3.106276589283335,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC420AA Pure 2,REC Group,Mono-c-Si,0,420.0,403.3,1.88,,,66.0,10.74,48.8,9.96,42.2,0.0039738,-0.11467999999999999,43.36,1.588940059458521,10.753856882046701,4.718866981332005e-13,0.13304493455511304,103.11862310553595,-10.545459284281245,-0.234,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC420AA Pure-R,REC Group,Mono-c-Si,0,420.0,402.5,1.88,,,80.0,8.89,59.4,8.4,50.0,0.0036449000000000004,-0.13959,45.07,1.8836049219855475,8.900871415854223,1.756194213095016e-13,0.3866814360455239,316.20517627326063,-16.612864134017933,-0.225,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC425AA 72,REC Group,Mono-c-Si,0,425.0,402.8,2.06,,,72.0,10.23,52.6,9.49,44.8,0.0029667,-0.12361,45.16,1.769278320109232,10.247800797609651,1.204389277590373e-12,0.21476743246418237,123.42541512236862,-2.70479296250979,-0.272,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC425AA 72 XV,REC Group,Mono-c-Si,0,425.0,402.8,2.06,,,72.0,10.23,52.6,9.49,44.8,0.0029667,-0.12361,45.16,1.769278320109232,10.247800797609651,1.204389277590373e-12,0.21476743246418237,123.42541512236862,-2.70479296250979,-0.272,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC430AA 72,REC Group,Mono-c-Si,0,430.0,407.6,2.06,,,72.0,10.25,52.7,9.54,45.1,0.0029725000000000003,-0.123845,45.16,1.7738480583904839,10.2643769493811,1.2356672965917483e-12,0.18986416182810376,135.36304590669442,-2.5261753240596376,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC430AA 72 XV,REC Group,Mono-c-Si,0,430.0,407.6,2.055,,,72.0,10.25,52.7,9.54,45.1,0.0029725000000000003,-0.123845,45.16,1.7738480583904839,10.2643769493811,1.2356672965917483e-12,0.18986416182810376,135.36304590669442,-2.5261753240596376,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC430AA Pure 2,REC Group,Mono-c-Si,0,430.0,413.1,1.88,,,66.0,10.81,49.0,10.05,42.8,0.0039997,-0.11514999999999999,43.36,1.6008892633964775,10.818459008993228,5.283264702231268e-13,0.08551876271043708,109.28677646342005,-9.741401177209449,-0.234,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC430AA Pure-R,REC Group,Mono-c-Si,0,430.0,412.2,1.88,,,80.0,8.97,59.7,8.52,50.5,0.0036777000000000003,-0.140295,45.07,1.8930227815106133,8.977211423036518,1.7791951433076048e-13,0.35277067981929655,438.7973047493762,-16.60389584440545,-0.225,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC430AA Pure-RX,REC Group,Mono-c-Si,0,430.0,409.7,2.02,,,88.0,8.67,64.5,8.12,53.0,0.0036414000000000004,-0.150285,45.22,2.095246477127375,8.689965098965564,3.6055303787349285e-13,0.5911687913219423,256.71966017160577,-10.342981191847683,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC435AA 72,REC Group,Mono-c-Si,0,435.0,412.4,2.06,,,72.0,10.27,52.9,9.59,45.4,0.0029783,-0.124315,45.16,1.780205112814074,10.282006051011834,1.2347931548206323e-12,0.17567933995987625,150.27643637459107,-2.562008130078946,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC435AA 72 XV,REC Group,Mono-c-Si,0,435.0,412.4,2.06,,,72.0,10.27,52.9,9.59,45.4,0.0029783,-0.124315,45.16,1.780205112814074,10.282006051011834,1.2347931548206323e-12,0.17567933995987625,150.27643637459107,-2.562008130078946,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC440AA 72,REC Group,Mono-c-Si,0,440.0,417.3,2.06,,,72.0,10.31,53.0,9.63,45.7,0.0029899000000000006,-0.12455,45.16,1.787222362716298,10.320294451380297,1.3171388415003189e-12,0.15028547000569406,150.51245945926962,-2.0683011239361333,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC440AA 72 XV,REC Group,Mono-c-Si,0,440.0,417.3,2.06,,,72.0,10.31,53.0,9.63,45.7,0.0029899000000000006,-0.12455,45.16,1.787222362716298,10.320294451380297,1.3171388415003189e-12,0.15028547000569406,150.51245945926962,-2.0683011239361333,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC440AA Pure-RX,REC Group,Mono-c-Si,0,440.0,419.4,2.02,,,88.0,8.74,64.8,8.2,53.7,0.0036708000000000005,-0.150984,45.22,2.1115502573077425,8.756982143958862,4.0044597538749103e-13,0.5263677731316017,270.8995018041765,-9.605447000953307,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC440AA Pure-RX-DC,REC Group,Mono-c-Si,0,440.0,419.4,2.02,,,88.0,8.74,65.6,8.2,53.7,0.0036708000000000005,-0.15284799999999998,45.22,2.1257071748544893,8.759299336854198,3.3755640890867645e-13,0.6244189425866751,282.7776692953129,-10.914724210559749,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC440AA Pure-RXG,REC Group,Mono-c-Si,0,440.0,420.7,2.02,,,44.0,8.74,65.4,8.2,53.7,0.0028842000000000004,-0.151074,46.86,2.038908465013254,8.760797482083909,9.99000000039973e-14,0.6234294266115461,261.991964554552,-18.94786412908681,-0.215,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC445AA 72,REC Group,Mono-c-Si,0,445.0,422.1,2.06,,,72.0,10.38,53.2,9.68,46.0,0.0030102,-0.12502,45.16,1.7976190602619573,10.3898405848838,1.4055292042803787e-12,0.13458979299294305,141.96737980951642,-1.584796427767475,-0.272,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC445AA 72 XV,REC Group,Mono-c-Si,0,445.0,422.1,2.06,,,72.0,10.38,53.2,9.68,46.0,0.0030102,-0.12502,45.16,1.7976190602619573,10.3898405848838,1.4055292042803787e-12,0.13458979299294305,141.96737980951642,-1.584796427767475,-0.272,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC445AA Pure-RX-DC,REC Group,Mono-c-Si,0,445.0,424.2,2.02,,,88.0,8.77,65.6,8.25,54.0,0.0036834000000000003,-0.15284799999999998,45.22,2.128700502938137,8.7861095289445,3.546477707996725e-13,0.5807257255230945,316.14609162185826,-10.574205437082965,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC450AA 72,REC Group,Mono-c-Si,0,450.0,427.0,2.055,,,72.0,10.43,53.2,9.72,46.3,0.0030247000000000004,-0.12502,45.16,1.8036432789545758,10.437511521451551,1.557018642916451e-12,0.0989580496854696,137.40657802043876,-0.7785106599354115,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC450AA 72 XV,REC Group,Mono-c-Si,0,450.0,427.0,2.055,,,72.0,10.43,53.2,9.72,46.3,0.0030247000000000004,-0.12502,45.16,1.8036432789545758,10.437511521451551,1.557018642916451e-12,0.0989580496854696,137.40657802043876,-0.7785106599354115,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC450AA Pure-RX,REC Group,Mono-c-Si,0,450.0,429.1,2.02,,,88.0,8.81,65.1,8.29,54.3,0.0037002000000000007,-0.15168299999999998,45.22,2.124898429751744,8.823756547141096,4.262369890944684e-13,0.4765796274297767,305.2122361850736,-9.196810334565058,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC450AA Pure-RX-DC,REC Group,Mono-c-Si,0,450.0,429.1,2.02,,,88.0,8.81,65.6,8.29,54.3,0.0037002000000000007,-0.15284799999999998,45.22,2.1337967163512657,8.825059759569088,3.834112142191995e-13,0.5371136376661427,314.21292791962753,-10.012769243457994,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC450AA Pure-RXG,REC Group,Mono-c-Si,0,450.0,430.4,2.02,,,44.0,8.81,65.6,8.29,54.3,0.0029073000000000007,-0.15153599999999998,46.86,2.044470043219218,8.82702111974129,9.990000000401765e-14,0.562235765853712,291.0088861821656,-19.01320375704982,-0.215,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC455AA Pure-RX,REC Group,Mono-c-Si,0,455.0,434.0,2.02,,,88.0,8.84,65.6,8.34,54.6,0.0037128000000000005,-0.15284799999999998,45.22,2.136734354781306,8.852302476459966,4.023500106059048e-13,0.4944997788161797,355.32504857204003,-9.678491674163906,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC455AA Pure-RX-DC,REC Group,Mono-c-Si,0,455.0,434.0,2.02,,,88.0,8.84,65.6,8.34,54.6,0.0037128000000000005,-0.15284799999999998,45.22,2.136734354781306,8.852302476459966,4.023500106059048e-13,0.4944997788161797,355.32504857204003,-9.678491674163906,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC460AA Pure-RX,REC Group,Mono-c-Si,0,460.0,438.8,2.02,,,88.0,8.88,65.3,8.38,54.9,0.0037296000000000004,-0.152149,45.22,2.1364161028978894,8.890667868613976,4.627241443666106e-13,0.4159607125200408,346.248277100342,-8.633121584964226,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC460AA Pure-RX-DC,REC Group,Mono-c-Si,0,460.0,438.8,2.02,,,88.0,8.88,65.7,8.38,54.9,0.0037296000000000004,-0.15308100000000002,45.22,2.1435745855026274,8.891595122972056,4.254395147258569e-13,0.4638044708434295,355.199656948798,-9.28398047549126,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC460AA Pure-RXG,REC Group,Mono-c-Si,0,460.0,440.1,2.02,,,44.0,8.88,65.8,8.38,54.9,0.0029304,-0.15199800000000002,46.86,2.0500341304473984,8.893664288960728,9.990000001092867e-14,0.5024420098017867,326.5215672885822,-19.07810429182832,-0.215,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC465AA Pure-RX,REC Group,Mono-c-Si,0,465.0,443.7,2.02,,,88.0,8.91,65.7,8.43,55.2,0.0037422,-0.15308100000000002,45.22,2.1464654028751537,8.919224070825054,4.459898875730598e-13,0.422149534923267,407.7757454795782,-8.95547243438143,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC465AA Pure-RX-DC,REC Group,Mono-c-Si,0,465.0,443.7,2.02,,,88.0,8.91,65.7,8.43,55.2,0.0037422,-0.15308100000000002,45.22,2.1464654028751537,8.919224070825054,4.459898875730598e-13,0.422149534923267,407.7757454795782,-8.95547243438143,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC470AA Pure-RX,REC Group,Mono-c-Si,0,470.0,448.6,2.02,,,88.0,8.95,65.7,8.49,55.4,0.003759,-0.15308100000000002,45.22,2.147535192890768,8.957290065580562,4.561160935581698e-13,0.39387720912645935,483.5622693692483,-8.82680480208966,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC470AA Pure-RX-DC,REC Group,Mono-c-Si,0,470.0,448.6,2.02,,,88.0,8.95,65.7,8.49,55.4,0.003759,-0.15308100000000002,45.22,2.147535192890768,8.957290065580562,4.561160935581698e-13,0.39387720912645935,483.5622693692483,-8.82680480208966,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC475AA Pure-RX,REC Group,Mono-c-Si,0,475.0,453.5,2.02,,,88.0,9.0,65.7,8.56,55.5,0.00378,-0.15308100000000002,45.22,2.146827089002435,9.005662148729202,4.553813548745505e-13,0.37876618238921195,602.0497523422222,-8.893316727888982,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC475AA Pure-RX-DC,REC Group,Mono-c-Si,0,475.0,453.5,2.02,,,88.0,9.0,65.7,8.56,55.5,0.00378,-0.15308100000000002,45.22,2.146827089002435,9.005662148729202,4.553813548745505e-13,0.37876618238921195,602.0497523422222,-8.893316727888982,-0.248,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC590AA Pro M,REC Group,Mono-c-Si,0,590.0,562.1,2.77,,,60.0,17.34,44.1,16.67,36.0,0.007282800000000001,-0.101871,45.97,1.3995237740675113,17.340004365346704,3.5819261687621433e-13,0.21275187352866518,845092.3990860804,-14.923641027034243,-0.239,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC590AA Pro MG,REC Group,Mono-c-Si,0,590.0,562.1,2.77,,,60.0,17.34,44.1,16.5,35.8,0.007629599999999999,-0.102312,46.54,1.3919760106584735,17.354349643452267,2.9947693754317727e-13,0.23466683770828597,283.5696218437729,-16.598700877211623,-0.233,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC600AA Pro M,REC Group,Mono-c-Si,0,600.0,571.8,2.77,,,60.0,17.45,44.2,16.5,35.8,0.007329,-0.10210200000000001,45.97,1.4039931474269114,17.477186679357253,3.655510646897149e-13,0.23888096564448566,153.32776749738852,-14.766238552523985,-0.239,N,2025.7.3,6/23/2025,4.0,bootstrapping +REC Group REC600AA Pro MG,REC Group,Mono-c-Si,0,600.0,571.8,2.77,,,60.0,17.45,44.2,16.67,36.0,0.007677999999999999,-0.10254400000000002,46.54,1.3949808447230063,17.45671479307941,3.01612949447874e-13,0.22532950316255773,585.5727475841073,-16.607970333641312,-0.233,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC610AA Pro M,REC Group,Mono-c-Si,0,610.0,581.5,2.77,,,60.0,17.56,44.4,16.81,36.3,0.007375199999999999,-0.102564,45.97,1.4091930761680302,17.562756412190435,3.6333068339899107e-13,0.2146470653378267,1367.4306358600786,-14.905460871504902,-0.239,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC610AA Pro MG,REC Group,Mono-c-Si,0,610.0,581.5,2.77,,,60.0,17.56,44.4,16.81,36.3,0.007726399999999999,-0.103008,46.54,1.4024567086283253,17.563108026951458,3.1223864839738373e-13,0.21556686976370043,1217.9283827289594,-16.409992186247383,-0.233,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC620AA Pro M,REC Group,Mono-c-Si,0,620.0,591.3,2.77,,,60.0,17.67,44.6,16.94,36.6,0.007421400000000002,-0.103026,45.97,1.4170259643894325,17.67055405839454,3.783878470383411e-13,0.20508725102074082,6540.63144000017,-14.657439997196402,-0.239,N,2025.7.3,6/23/2025,4.0,first_pass +REC Group REC620AA Pro MG,REC Group,Mono-c-Si,0,620.0,591.2,2.77,,,60.0,17.67,44.6,16.94,36.6,0.007774800000000001,-0.10347200000000001,46.54,1.4102549695581983,17.67088090894671,3.2525084226423224e-13,0.2060069775432754,4132.258049565904,-16.16374383613847,-0.233,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC630AA Pro M,REC Group,Mono-c-Si,0,630.0,601.0,2.77,,,60.0,17.78,44.7,17.12,36.8,0.007467600000000001,-0.10325700000000002,45.97,1.4239167526248875,17.780003937001712,4.1346101835935045e-13,0.1875066019128199,846804.4543023999,-14.049757315034457,-0.239,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC630AA Pro MG,REC Group,Mono-c-Si,0,630.0,600.9,2.77,,,60.0,17.78,44.7,17.12,36.8,0.0078232,-0.10370400000000002,46.54,1.416922090748402,17.78000395353663,3.54105417637445e-13,0.18885229395443653,849314.6575000796,-15.591801210436087,-0.233,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC640AA Pro M,REC Group,Mono-c-Si,0,640.0,610.7,2.77,,,60.0,17.89,44.9,17.26,37.1,0.007513800000000001,-0.103719,45.97,1.4333330577008216,17.890003665814536,4.4471255129741723e-13,0.17401940797891105,849254.6545084391,-13.554696174684013,-0.239,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC640AA Pro MG,REC Group,Mono-c-Si,0,640.0,610.7,2.77,,,60.0,17.89,44.9,17.26,37.1,0.0078716,-0.10416800000000001,46.54,1.4262969792587916,17.89000368330284,3.8103666138135283e-13,0.17538356925349083,851848.1087761284,-15.100490014348129,-0.233,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC650AA Pro L,REC Group,Mono-c-Si,1,650.0,608.7,3.06,,,66.0,16.14,49.1,15.4,42.2,0.0067788000000000015,-0.13060600000000003,45.57,1.79186487746295,16.14209685623009,2.0202000578997852e-11,0.07844495608721586,603.8094484448843,3.9578237844465813,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC660AA Pro L,REC Group,Mono-c-Si,1,660.0,618.3,3.06,,,66.0,16.35,49.2,15.6,42.4,0.006867000000000001,-0.13087200000000002,45.57,1.7979220048832865,16.3519885404787,2.1224346710682638e-11,0.06926600017005963,569.5127283386623,4.266967144568598,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC670AA Pro L,REC Group,Mono-c-Si,1,670.0,628.0,3.06,,,66.0,16.55,49.2,15.79,42.5,0.006951000000000001,-0.13087200000000002,45.57,1.800058683296094,16.55188542167901,2.2187549533626983e-11,0.0612107856187805,537.3007652988597,4.541166947460816,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC680AA Pro L,REC Group,Mono-c-Si,1,680.0,637.6,3.06,,,66.0,16.76,49.3,16.01,42.6,0.0070392000000000015,-0.131138,45.57,1.8029202751912543,16.761398166706698,2.2230444102317067e-11,0.05980734064681324,716.9181159754708,4.445089337558488,-0.327,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC720AA Pro XL,REC Group,Mono-c-Si,1,720.0,686.9,3.33,,,72.0,16.39,53.6,15.6,46.2,0.006228200000000001,-0.12060000000000001,44.85,1.7517599478918102,16.396888698268526,8.329454324122425e-13,0.10556651128397959,251.17011267976886,-5.529805837183032,-0.247,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC730AA Pro XL,REC Group,Mono-c-Si,1,730.0,696.6,3.33,,,72.0,16.57,53.7,15.79,46.3,0.0062966,-0.12082500000000002,44.85,1.7543548483644371,16.576177557641312,8.333825433058686e-13,0.10376892301177659,278.338326321949,-5.618485045111805,-0.247,N,2025.7.3,6/23/2025,2.0,first_pass +REC Group REC740AA Pro XL,REC Group,Mono-c-Si,1,740.0,706.4,3.33,,,72.0,16.75,53.8,15.97,46.3,0.006365,-0.12105,44.85,1.7557837278161916,16.756188279637186,8.164866682898206e-13,0.10895999639684316,294.925253396358,-5.871558296973839,-0.247,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-250-6MB,Recom,Mono-c-Si,0,250.0,225.4,1.6268799999999999,1.64,0.992,60.0,8.51,37.92,8.09,31.3,0.004255,-0.12134400000000002,46.9,1.546723210793676,8.516955457749733,1.9185320195657347e-10,0.24602418349055954,999999.9270694582,8.873699529420799,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-250-6PB,Recom,Multi-c-Si,0,250.0,222.7,1.6268799999999999,1.64,0.992,60.0,8.92,37.1,8.35,30.2,0.00446,-0.12243000000000001,48.8,1.5309422782289601,8.92980544935076,2.6261652584537827e-10,0.2828301564952976,257.290124013094,7.903845186163298,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-255-6PB,Recom,Multi-c-Si,0,255.0,227.2,1.6268799999999999,1.64,0.992,60.0,8.93,37.6,8.41,30.5,0.004465,-0.12408000000000001,48.8,1.5435786743658817,8.935216264964286,2.336592095197345e-10,0.30175835655622957,516.5962069539785,6.858960843581744,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-260-6MB,Recom,Mono-c-Si,0,260.0,234.7,1.6268799999999999,1.64,0.992,60.0,8.66,38.52,8.3,31.7,0.00433,-0.12326400000000001,46.9,1.575635096417486,8.66000188771645,2.0902351807101492e-10,0.2179243399290535,999995.6302950174,9.480789239136735,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-260-6MB-BB,Recom,Mono-c-Si,0,260.0,235.1,1.6288639999999999,1.642,0.992,60.0,8.66,38.52,8.32,31.7,0.00433,-0.12326400000000001,46.56,1.5778989534506846,8.660155840242693,2.1640511872689106e-10,0.2042206128071662,11348.516364715442,9.788698212537318,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-260-6PB,Recom,Multi-c-Si,0,260.0,231.8,1.6268799999999999,1.64,0.992,60.0,8.94,38.0,8.47,30.8,0.00447,-0.1254,48.8,1.554485513527137,8.940275723623529,2.1610735162414227e-10,0.30833658604990044,9997.473565868391,6.15633499949785,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-265-6MB-BB,Recom,Mono-c-Si,0,265.0,239.7,1.6288639999999999,1.642,0.992,60.0,8.72,38.64,8.39,31.91,0.004360000000000001,-0.12364800000000001,46.56,1.5864917684384867,8.720138864449154,2.3059004575052935e-10,0.181463148633558,11395.019606266349,10.290541176463169,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-270-6MB,Recom,Mono-c-Si,0,270.0,244.0,1.6268799999999999,1.64,0.992,60.0,8.78,38.76,8.45,32.12,0.00439,-0.124032,46.9,1.5941934450028368,8.780126957998734,2.42230680191398e-10,0.16523178058670887,11426.92174342924,10.668048660650392,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-270-6MB-BB,Recom,Mono-c-Si,0,270.0,244.4,1.6288639999999999,1.642,0.992,60.0,8.78,38.76,8.45,32.12,0.00439,-0.124032,46.56,1.5941934450028368,8.780126957998734,2.42230680191398e-10,0.16523178058670887,11426.92174342924,10.668048660650392,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-275-6MB-BB,Recom,Mono-c-Si,0,275.0,249.0,1.6288639999999999,1.642,0.992,60.0,8.89,38.98,8.56,32.31,0.004445,-0.124736,46.56,1.603783126355764,8.89012514325454,2.47286092350828e-10,0.1605828137096977,11407.608367476236,10.74126237459631,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-280-6MB-BB,Recom,Mono-c-Si,0,280.0,253.7,1.6288639999999999,1.642,0.992,60.0,8.99,39.2,8.67,32.5,0.004495000000000001,-0.12544,46.56,1.6141377949540412,8.990100493371378,2.550373326047583e-10,0.15043399459897097,13457.664833870076,10.916870808924523,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-285-6PA,Recom,Multi-c-Si,0,285.0,256.9,1.9403519999999999,1.956,0.992,72.0,8.44,44.7,7.94,36.2,0.004220000000000001,-0.13857000000000003,46.2,1.8284598099700644,8.44591605905992,2.0201402741436368e-10,0.3898220325075829,556.1300792658504,12.99005031744385,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-290-6PA,Recom,Multi-c-Si,0,290.0,261.5,1.9403519999999999,1.956,0.992,72.0,8.56,44.8,8.0,36.3,0.004280000000000001,-0.13887999999999998,46.2,1.8393482638091367,8.571206863634206,2.2249418068077648e-10,0.3820110896035817,291.78683286860974,13.769983978973057,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-295-6PA,Recom,Multi-c-Si,0,295.0,266.2,1.9403519999999999,1.956,0.992,72.0,8.67,44.9,8.11,36.4,0.004335,-0.13919,46.2,1.843142096073046,8.680598606221691,2.2465065433722277e-10,0.3753168996382166,307.021299397411,13.73805573093529,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-300-6PA,Recom,Multi-c-Si,0,300.0,270.8,1.9403519999999999,1.956,0.992,72.0,8.69,44.8,8.2,36.6,0.004345,-0.13887999999999998,46.2,1.8386387882092694,8.693753735073235,2.2612473148203996e-10,0.3339663120136382,773.1413377228016,13.744969827717085,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-305-6PA,Recom,Multi-c-Si,0,305.0,275.4,1.9403519999999999,1.956,0.992,72.0,8.77,44.95,8.33,36.82,0.004385,-0.139345,46.2,1.84219204531651,8.779175475507811,2.2209815484702338e-10,0.3185496707202616,999999.9843997115,13.465897308291847,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-310-6PA,Recom,Multi-c-Si,0,310.0,280.1,1.9403519999999999,1.956,0.992,72.0,8.92,45.0,8.42,37.0,0.00446,-0.1395,46.2,1.853105471447524,8.923600405819013,2.519448162739678e-10,0.2939135911835243,728.1706332643056,14.500543903329103,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-315-6MA,Recom,Mono-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.68,46.7,8.32,38.2,0.0034720000000000003,-0.14477,46.66,1.8637503872625913,8.680002679689174,1.1386733697835047e-10,0.3086664232858178,999963.0352706827,7.738891131678761,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-315-6PA,Recom,Multi-c-Si,0,315.0,286.6,1.9403519999999999,1.956,0.992,72.0,8.95,45.4,8.44,37.8,0.004475,-0.1362,46.9,1.8042225195723576,8.95520135511147,1.043986028798543e-10,0.2501900847878343,430.50345946336853,10.221483177310137,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-320-6MA,Recom,Mono-c-Si,0,320.0,290.1,1.9403519999999999,1.956,0.992,72.0,8.75,46.8,8.42,38.3,0.0035000000000000005,-0.14508,46.66,1.872112751478429,8.750201205540277,1.2165170414461897e-10,0.2786885999945864,12119.592463818424,8.244818744366155,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-320-6PA,Recom,Multi-c-Si,0,320.0,291.2,1.9403519999999999,1.956,0.992,72.0,8.99,45.94,8.46,38.23,0.004495000000000001,-0.13782,46.9,1.8271524583221777,8.996402386282401,1.067506932578695e-10,0.25434629884738663,357.14391805121704,10.388299604659572,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-325-6MA,Recom,Mono-c-Si,0,325.0,294.8,1.9403519999999999,1.956,0.992,72.0,8.8,47.0,8.49,38.4,0.0035200000000000006,-0.1457,46.66,1.8807980079209154,8.800165556256273,1.2347350448152595e-10,0.26988960601069134,14345.767442175858,8.324401168025366,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-325-6PA,Recom,Multi-c-Si,0,325.0,295.9,1.9403519999999999,1.956,0.992,72.0,9.02,46.15,8.49,38.47,0.00451,-0.13845,46.9,1.8369995218880983,9.02615434015096,1.0932906605386121e-10,0.24576412974270737,360.19987328536627,10.570908224708315,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-330-6MA,Recom,Mono-c-Si,0,330.0,299.5,1.9403519999999999,1.956,0.992,72.0,8.86,47.1,8.61,38.5,0.003544,-0.14601,46.66,1.8915474339429788,8.860154258882321,1.358975618014214e-10,0.21231648450088864,12194.609501743453,9.103325521932868,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-330-6PA,Recom,Multi-c-Si,0,330.0,300.6,1.9403519999999999,1.956,0.992,72.0,9.07,46.51,8.54,38.83,0.004535,-0.13953,46.9,1.8525509781460177,9.075865494242258,1.117997570930789e-10,0.23823037743608313,368.3832129286098,10.720037960062497,-0.4,N,2025.7.3,6/23/2025,4.0,first_pass +Recom RCM-335-6MA,Recom,Mono-c-Si,0,335.0,304.1,1.9403519999999999,1.956,0.992,72.0,8.93,47.4,8.73,38.7,0.003572,-0.14694,46.66,1.907777705752974,8.930118868116805,1.446555383607258e-10,0.16300947916457398,12246.148776476406,9.583260390523616,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-340-6MA,Recom,Mono-c-Si,0,340.0,308.8,1.9403519999999999,1.956,0.992,72.0,8.99,47.6,8.82,38.8,0.0035960000000000002,-0.14756,46.66,1.9175186974398994,8.990096100863513,1.4885388501869513e-10,0.13105992610359937,12260.350366459352,9.77653789976475,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +Recom RCM-345-6MA,Recom,Mono-c-Si,0,345.0,313.5,1.9403519999999999,1.956,0.992,72.0,9.05,47.9,8.91,38.9,0.0036200000000000004,-0.14848999999999998,46.66,1.9294130655538757,9.050075590132613,1.4947961112538944e-10,0.10248622811713017,12270.139539706908,9.7548684377006,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM & Co Ltd RCM-395-7BMG,RECOM & Co Ltd,Mono-c-Si,1,395.0,371.7,1.93,,,54.0,13.69,36.78,13.04,30.3,0.0064343,-0.09378900000000001,43.6,1.3273868910488578,13.692608237272772,1.2635173940026697e-11,0.18191486034440194,954.8266680474202,5.737284210443168,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-400-7BMG,RECOM & Co Ltd,Mono-c-Si,1,400.0,376.5,1.93,,,54.0,13.74,37.08,13.08,30.59,0.0064578,-0.09455399999999999,43.6,1.339491148343632,13.743358095132036,1.3010174317910424e-11,0.1789693953956059,732.2721502895592,5.9613139833370115,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-405-7BMG,RECOM & Co Ltd,Mono-c-Si,1,405.0,381.3,1.93,,,54.0,13.79,37.38,13.13,30.87,0.0064813,-0.095319,43.6,1.3509137882797184,13.793207629751555,1.3216534563964103e-11,0.176927734974341,760.6341210605252,6.065500099365578,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-410-7BMG,RECOM & Co Ltd,Mono-c-Si,1,410.0,386.1,1.93,,,54.0,13.83,37.68,13.18,31.17,0.0065001,-0.096084,43.6,1.362312163857925,13.832292739632639,1.3417487346418004e-11,0.17330485260001727,1045.389604988881,6.167571397989583,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-415-7BMG,RECOM & Co Ltd,Mono-c-Si,1,415.0,391.0,1.93,,,54.0,13.87,37.98,13.22,31.43,0.006518899999999999,-0.09684899999999999,43.6,1.3733225074543407,13.87216398486748,1.3502537636343649e-11,0.17315870092648045,1109.8566396493475,6.196765966276984,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-425-7BNG,RECOM & Co Ltd,Mono-c-Si,1,425.0,402.8,1.95,,,54.0,14.05,38.3,13.23,32.2,0.006884500000000001,-0.08770700000000001,43.5,1.3515387448935687,14.064517819158244,6.792911468023796e-12,0.13717338162298207,132.7531356573545,11.806866153067405,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-430-7BNG,RECOM & Co Ltd,Mono-c-Si,1,430.0,407.6,1.95,,,54.0,14.13,38.4,13.28,32.5,0.0069237000000000005,-0.087936,43.5,1.3605506460870964,14.14429589091297,7.636481749474214e-12,0.11811811600070628,116.74746206756764,12.845732078085785,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-435-7BNG,RECOM & Co Ltd,Mono-c-Si,1,435.0,412.5,1.95,,,54.0,14.22,38.5,13.32,32.8,0.006967800000000001,-0.08816500000000001,43.5,1.370514591952998,14.23437706582374,8.732280216170539e-12,0.09898062338916118,97.89928513682227,14.052795944076568,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-440-7BNG,RECOM & Co Ltd,Mono-c-Si,1,440.0,417.3,1.95,,,54.0,14.3,38.6,13.36,33.0,0.007007000000000001,-0.088394,43.5,1.3780670561223085,14.314517686137044,9.494057576115711e-12,0.08861308508211539,87.28437203850729,14.798261551080351,-0.303,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM & Co Ltd RCM-500-7BMM,RECOM & Co Ltd,Mono-c-Si,0,500.0,465.4,2.17,,,66.0,13.91,45.7,13.25,37.8,0.0062594999999999994,-0.13070199999999998,45.5,1.7309025027984761,13.910639708420955,4.7488805960270474e-11,0.19637400421187637,4270.013351527136,4.769649634817445,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-505-7BMM,RECOM & Co Ltd,Mono-c-Si,0,505.0,470.2,2.17,,,66.0,13.96,45.9,13.3,38.0,0.006282,-0.131274,45.5,1.739146067412781,13.960528704535948,4.815132817023929e-11,0.19353699438640584,5110.18435801016,4.856129487252281,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-510-7BMM,RECOM & Co Ltd,Mono-c-Si,0,510.0,475.0,2.17,,,66.0,14.01,46.1,13.36,38.2,0.0063045,-0.131846,45.5,1.7472956678979035,14.010002658237868,4.877221326816449e-11,0.18972581398060054,999999.8936380455,4.932212358457371,-0.37,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM & Co Ltd RCM-530-7BMF,RECOM & Co Ltd,Mono-c-Si,1,530.0,490.5,2.56,,,72.0,13.6,49.2,12.79,41.46,0.00272,-0.12890400000000002,45.3,1.8726755266482549,13.61055169884683,5.195649284510466e-11,0.14988400789361014,193.18429624396282,15.862509528357533,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-535-7BMF,RECOM & Co Ltd,Mono-c-Si,1,535.0,495.3,2.56,,,72.0,13.65,49.5,12.83,41.72,0.0027300000000000002,-0.12969,45.3,1.8847858201350352,13.660917831033949,5.261782697712879e-11,0.14951671143614004,186.93302032749133,15.948919590135086,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-540-7BMF,RECOM & Co Ltd,Mono-c-Si,1,540.0,500.1,2.56,,,72.0,13.7,49.8,12.86,42.0,0.00274,-0.130476,45.3,1.8981205533034566,13.711674392691476,5.413850762244947e-11,0.14723822933014497,172.7853274013732,16.187351530613974,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-545-7BMF,RECOM & Co Ltd,Mono-c-Si,1,545.0,504.8,2.56,,,72.0,13.75,50.1,12.9,42.26,0.0027500000000000003,-0.13126200000000002,45.3,1.9102431292163335,13.762025598989837,5.4816457962867896e-11,0.14687724386428394,167.93858879872545,16.272282639581686,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-550-7BMF,RECOM & Co Ltd,Mono-c-Si,1,550.0,509.6,2.56,,,72.0,13.8,50.4,12.95,42.5,0.0027600000000000003,-0.132048,45.3,1.9211408414100934,13.811994217614405,5.462800367847317e-11,0.14842082593309427,170.76623765593587,16.204910794275076,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-555-7BMF,RECOM & Co Ltd,Mono-c-Si,1,555.0,514.4,2.56,,,72.0,13.85,50.7,12.99,42.77,0.0027700000000000003,-0.132834,45.3,1.933502223255321,13.86228120542209,5.548221084757569e-11,0.14717062265130415,165.97012057596058,16.318867101184857,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM & Co Ltd RCM-560-7BMF,RECOM & Co Ltd,Mono-c-Si,1,560.0,519.2,2.56,,,72.0,13.9,50.98,13.04,43.0,0.0027800000000000004,-0.1335676,45.3,1.9437978498201633,13.912208172304936,5.541224375183952e-11,0.14803774466733954,168.55304931108932,16.272165238243687,-0.385,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-270-6PB,RECOM SILLIA,Multi-c-Si,0,270.0,244.9,1.62,1.96,0.99,60.0,9.2,38.0,8.55,31.6,0.0043884,-0.140182,46.0,1.5884237160201666,9.21150132101464,3.6533823778737563e-10,0.1896988383396835,151.741649623806,-1.124540054844892,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-275-6PB,RECOM SILLIA,Multi-c-Si,0,275.0,249.5,1.62,1.96,0.99,60.0,9.25,38.15,8.65,31.8,0.0044122499999999995,-0.14073535,46.0,1.5913184091249883,9.258030074995691,3.516579097906381e-10,0.1804653184573774,207.88153687465112,-1.4916608909290423,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-280-6PB,RECOM SILLIA,Multi-c-Si,0,280.0,254.2,1.62,1.96,0.99,60.0,9.35,38.3,8.75,32.0,0.00445995,-0.14128870000000002,46.0,1.5991017188629166,9.357395063850289,3.639219421063286e-10,0.16933890099551285,214.10482561960362,-1.3063572454786683,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-285-6PB,RECOM SILLIA,Multi-c-Si,0,285.0,251.1,1.62,1.96,0.99,60.0,8.83,43.0,8.14,35.0,0.0055629,-0.15436999999999998,48.8,1.9185623101585405,8.846805009901344,1.582588497210171e-09,0.2969708876930899,156.0399949465346,14.633486184154888,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-290-6PB,RECOM SILLIA,Multi-c-Si,0,290.0,255.7,1.62,1.96,0.99,60.0,8.99,43.0,8.27,35.0,0.005663700000000001,-0.15436999999999998,48.8,1.9209080453700518,9.008527593678375,1.6517476109802664e-09,0.2912701735990936,141.33079476427875,14.873123879330512,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-295-6MB,RECOM SILLIA,Mono-c-Si,0,295.0,270.9,1.61,1.96,0.99,60.0,9.55,39.6,9.05,32.6,0.0048991500000000006,-0.12347280000000001,45.4,1.5711018558350105,9.55241960615854,1.0759453742064643e-10,0.2502872567884695,987.8647701121014,5.685747897931503,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-300-6MB,RECOM SILLIA,Mono-c-Si,0,300.0,275.6,1.61,1.96,0.99,60.0,9.7,39.7,9.2,32.7,0.004976099999999999,-0.12378460000000001,45.4,1.57484994146365,9.701849390573583,1.0900520122109731e-10,0.24487793749701034,1284.3779567910437,5.660812534088088,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-305-6MB,RECOM SILLIA,Mono-c-Si,0,305.0,280.3,1.61,1.96,0.99,60.0,9.8,39.8,9.3,32.8,0.0050274000000000004,-0.1240964,45.4,1.5788344998382555,9.801482396608446,1.1022595631111326e-10,0.24083255970365877,1592.124319929604,5.666328528462093,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-310-6MB,RECOM SILLIA,Mono-c-Si,0,310.0,285.0,1.61,1.96,0.99,60.0,9.9,39.9,9.43,32.9,0.0050787,-0.12440820000000001,45.4,1.5827400530193925,9.90000306941006,1.1150894809230532e-10,0.23665549392700028,763396.9632724393,5.670435472942462,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-315-6MB,RECOM SILLIA,Mono-c-Si,0,315.0,289.8,1.61,1.96,0.99,60.0,10.0,40.0,9.55,33.0,0.00513,-0.12472000000000001,45.4,1.5890278746532005,10.000002170149946,1.168602983335966e-10,0.21698083150913758,999999.8260907069,5.984453454861893,-0.4035,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-320-6PA,RECOM SILLIA,Multi-c-Si,0,320.0,288.7,1.92,,,72.0,9.15,46.5,8.5,37.65,0.006185400000000001,-0.171864,46.1,1.9880230016728035,9.164900921037205,6.219578345082189e-10,0.3563703713184628,218.8314034127128,2.8122258021638142,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-325-6PA,RECOM SILLIA,Multi-c-Si,0,325.0,293.4,1.92,,,72.0,9.2,46.6,8.6,37.8,0.006219199999999999,-0.17223360000000001,46.1,1.9875917397313407,9.20976607854768,5.959755449960036e-10,0.3463983858890514,326.319915067196,2.393044273532057,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-330-6PA,RECOM SILLIA,Multi-c-Si,0,330.0,298.0,1.92,,,72.0,9.25,46.7,8.7,37.95,0.006252999999999999,-0.1726032,46.1,1.9873146498140035,9.254900785039741,5.720081447198875e-10,0.33659456752006933,635.3066086099375,1.9892598261042769,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-335-6PA,RECOM SILLIA,Multi-c-Si,0,335.0,302.7,1.92,,,72.0,9.3,46.8,8.8,38.1,0.0062868,-0.17297279999999998,46.1,1.9871837944262367,9.300298189863414,5.498564720850979e-10,0.32695645871646173,10197.219709573346,1.6000840130540608,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-340-6PA,RECOM SILLIA,Multi-c-Si,0,340.0,309.6,1.92,,,72.0,9.35,46.9,8.9,38.25,0.005162883,-0.16023384999999998,45.3,1.9375598338800684,9.350002912654459,2.8734645914641267e-10,0.31140597406803927,999999.8916770768,4.454325040166477,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-345-6PA,RECOM SILLIA,Multi-c-Si,0,345.0,314.3,1.92,,,72.0,9.4,47.0,8.95,38.55,0.0051904920000000005,-0.1605755,45.3,1.9471812848852545,9.400002660212326,3.092875470952816e-10,0.2828978450197144,999999.1709747127,5.0311718804607946,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-350-6MA,RECOM SILLIA,Mono-c-Si,0,350.0,320.7,1.92,,,72.0,9.6,47.35,9.1,38.5,0.006115200000000001,-0.1520882,45.3,1.910823011400301,9.600714490183401,1.6598664567406e-10,0.3487964836929779,4686.484704435454,6.014678086956936,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-350-6PA,RECOM SILLIA,Multi-c-Si,0,350.0,319.0,1.92,,,72.0,9.45,47.1,9.0,38.9,0.005218101,-0.16091715,45.3,1.957996868345451,9.450002351515886,3.3759073651326017e-10,0.24874167782473292,999999.9418387699,5.7307985854247265,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-355-6MA,RECOM SILLIA,Mono-c-Si,0,355.0,325.4,1.92,,,72.0,9.65,47.45,9.18,38.7,0.006147050000000001,-0.1524094,45.3,1.9192241881460486,9.650003101754933,1.7669812433352938e-10,0.3213500363271102,999999.9301390301,6.503731305644137,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-360-6MA,RECOM SILLIA,Mono-c-Si,0,360.0,330.1,1.92,,,72.0,9.7,47.65,9.26,38.9,0.0061789,-0.1530518,45.3,1.9309222559756734,9.700003161909654,1.8601277883756734e-10,0.3258893882408683,999996.1043942207,6.901901227986124,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +RECOM SILLIA RCM-365-6MA,RECOM SILLIA,Mono-c-Si,0,365.0,334.8,1.92,,,72.0,9.75,47.85,9.34,39.1,0.006210750000000001,-0.1536942,45.3,1.9434371689863374,9.750002705694424,1.977409461490519e-10,0.27744468809648204,999995.9244658295,7.3865122780645915,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-370-6MA,RECOM SILLIA,Mono-c-Si,0,370.0,339.6,1.92,,,72.0,9.8,48.05,9.42,39.3,0.006242600000000001,-0.1543366,45.3,1.9562231407399029,9.800215145569869,2.1068433310124924e-10,0.2521744583130351,11486.71472222986,7.894569186971031,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-375-6MA,RECOM SILLIA,Mono-c-Si,0,375.0,348.2,1.92,,,72.0,9.85,48.25,9.5,39.5,0.007905117500000001,-0.14325425,44.8,1.898558856231294,9.850209607393328,9.038580966234218e-11,0.25227117438093266,11854.896301569443,8.835981560451906,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-380-6MA,RECOM SILLIA,Mono-c-Si,0,380.0,353.0,1.92,,,72.0,9.9,48.45,9.58,39.7,0.007945245000000002,-0.14384805,44.8,1.9101644687955268,9.900160015980582,9.547992585894394e-11,0.22736095001114454,14066.572683842796,9.275726702523857,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +RECOM SILLIA RCM-385-6MA,RECOM SILLIA,Mono-c-Si,0,385.0,357.7,1.92,,,72.0,9.95,48.65,9.65,39.9,0.0079853725,-0.14444184999999998,44.8,1.9209348861738653,9.950146670807648,9.968865130068386e-11,0.20789896650128015,14103.606068114472,9.613703899917482,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +ReCreate DS-MERCURY-470TC,ReCreate,Mono-c-Si,0,470.0,442.1,2.1,,,60.0,14.16,42.35,13.42,35.03,0.0058056,-0.09698150000000001,48.29,1.4174798774726511,14.173285430859762,1.4799030065744528e-12,0.21005639853542252,223.884239447864,-1.4327340864228986,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +ReCreate DS-MERCURY-475TC,ReCreate,Mono-c-Si,0,475.0,446.9,2.1,,,60.0,14.24,42.51,13.5,35.19,0.0058384000000000005,-0.0973479,48.29,1.423156672623322,14.252899029553,1.4987741154843283e-12,0.207338337839536,228.89302750425966,-1.375776879851754,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +ReCreate DS-MERCURY-480TC,ReCreate,Mono-c-Si,0,480.0,451.8,2.1,,,60.0,14.32,42.68,13.58,35.35,0.0058712,-0.09773720000000001,48.29,1.4290157649178847,14.332542628501203,1.512952825073357e-12,0.2053921060756905,234.49749478963628,-1.345489838477025,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +ReCreate DS-MERCURY-485TC,ReCreate,Mono-c-Si,0,485.0,456.6,2.1,,,60.0,14.4,42.85,13.66,35.51,0.005904000000000001,-0.09812650000000002,48.29,1.4348751799382098,14.412191532885835,1.5271790429385334e-12,0.20346868116843067,240.3265478580036,-1.315393425376564,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/410AB2,Regitec Solar BV,Mono-c-Si,1,410.0,386.3,1.95,,,54.0,13.93,38.2,12.98,31.6,0.0065471,-0.09588200000000002,45.67,1.3356491380207876,13.960388293359445,5.124149595243702e-12,0.18413479458168625,84.40742825009174,-0.26021696105047737,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/415B2,Regitec Solar BV,Mono-c-Si,1,415.0,391.1,1.95,,,54.0,14.01,38.33,13.06,31.79,0.0065847,-0.0962083,45.67,1.3416443952834993,14.03904906456081,5.3166590055566515e-12,0.17649520360063944,85.1214261500333,-0.004839890832581465,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/435B1,Regitec Solar BV,Mono-c-Si,0,415.0,389.5,1.95,,,54.0,14.31,38.68,13.57,32.07,0.0062964,-0.0955396,46.75,1.343747674056717,14.32032508888093,4.465434614405654e-12,0.17547794324460772,243.2026884016975,-0.028949574719098366,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/435B3,Regitec Solar BV,Mono-c-Si,0,415.0,389.5,1.95,,,54.0,14.31,38.68,13.57,32.07,0.0062964,-0.0955396,46.75,1.343747674056717,14.32032508888093,4.465434614405654e-12,0.17547794324460772,243.2026884016975,-0.028949574719098366,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/420B2,Regitec Solar BV,Mono-c-Si,1,420.0,396.0,1.95,,,54.0,14.09,38.46,13.14,31.97,0.0066223,-0.0965346,45.67,1.347429389247497,14.117857349054646,5.490350980094318e-12,0.16982138525825663,85.89415002263826,0.21221131021977954,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/430AB3,Regitec Solar BV,Mono-c-Si,0,420.0,394.3,1.95,,,54.0,14.23,38.49,13.49,31.88,0.0062612,-0.09507030000000001,46.75,1.3366817098704744,14.240699325465112,4.3950426728820405e-12,0.17833715266943864,237.18669895571645,-0.11270208969288932,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/430B1,Regitec Solar BV,Mono-c-Si,0,420.0,394.3,1.95,,,54.0,14.23,38.49,13.49,31.88,0.0062612,-0.09507030000000001,46.75,1.3366817098704744,14.240699325465112,4.3950426728820405e-12,0.17833715266943864,237.18669895571645,-0.11270208969288932,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/425AB2,Regitec Solar BV,Mono-c-Si,1,425.0,400.8,1.95,,,54.0,14.17,38.59,13.22,32.16,0.0066599,-0.0968609,45.67,1.353418715588137,14.196560542832488,5.692547274290865e-12,0.16236659392850145,86.62227472929747,0.4632531808065651,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Regitec Solar BV RMHT54/425AB3,Regitec Solar BV,Mono-c-Si,0,425.0,399.2,1.95,,,54.0,14.15,38.3,13.41,31.7,0.006226000000000001,-0.094601,46.75,1.329815431490237,14.16105633709614,4.343770104769106e-12,0.18038080826385383,230.8529868886778,-0.16181253009627064,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/425B1,Regitec Solar BV,Mono-c-Si,0,425.0,399.2,1.95,,,54.0,14.15,38.3,13.41,31.7,0.006226000000000001,-0.094601,46.75,1.329815431490237,14.16105633709614,4.343770104769106e-12,0.18038080826385383,230.8529868886778,-0.16181253009627064,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/420B1,Regitec Solar BV,Mono-c-Si,0,430.0,404.0,1.95,,,54.0,14.07,38.11,13.33,31.51,0.006190800000000001,-0.0941317,46.75,1.3227484945708519,14.08144730456784,4.2740958800493675e-12,0.18330466739746212,225.3016560157429,-0.24723940610152856,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/420B3,Regitec Solar BV,Mono-c-Si,0,430.0,404.0,1.95,,,54.0,14.07,38.11,13.33,31.51,0.006190800000000001,-0.0941317,46.75,1.3227484945708519,14.08144730456784,4.2740958800493675e-12,0.18330466739746212,225.3016560157429,-0.24723940610152856,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT54/430AB2,Regitec Solar BV,Mono-c-Si,1,430.0,405.6,1.95,,,54.0,14.25,38.72,13.3,32.34,0.0066975,-0.0971872,45.67,1.359198612923038,14.2754095512168,5.874747316341203e-12,0.1558629370336231,87.40992025105459,0.6763960637214603,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/415AB3,Regitec Solar BV,Mono-c-Si,0,435.0,408.8,1.95,,,54.0,13.99,37.92,13.25,31.32,0.0061556,-0.0936624,46.75,1.3156809517747357,14.001847298114734,4.204873074119106e-12,0.18626438775975857,219.9521583166828,-0.333632189456745,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH54/415B1,Regitec Solar BV,Mono-c-Si,0,435.0,408.8,1.95,,,54.0,13.99,37.92,13.25,31.32,0.0061556,-0.0936624,46.75,1.3156809517747357,14.001847298114734,4.204873074119106e-12,0.18626438775975857,219.9521583166828,-0.333632189456745,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/545S2,Regitec Solar BV,Mono-c-Si,1,545.0,513.6,2.58,,,72.0,13.9,50.04,13.19,41.33,0.006533000000000001,-0.1256004,45.67,1.7338028088749298,13.909533812531683,4.023555372408662e-12,0.24758991191091842,360.97833623986014,-2.2874884942437235,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/560S1,Regitec Solar BV,Mono-c-Si,0,545.0,511.4,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0062172,-0.1251549,46.75,1.7619813593777143,14.144568737652692,4.514566209112488e-12,0.23794574467647955,230.7800070388387,0.18127263990789724,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/560S3,Regitec Solar BV,Mono-c-Si,0,545.0,511.4,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0062172,-0.1251549,46.75,1.7619813593777143,14.144568737652692,4.514566209112488e-12,0.23794574467647955,230.7800070388387,0.18127263990789724,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/550S2,Regitec Solar BV,Mono-c-Si,1,550.0,518.4,2.58,,,72.0,13.98,50.18,13.26,41.48,0.0065706,-0.1259518,45.67,1.7396919469539565,13.990069676090698,4.114563786953215e-12,0.2439056363853141,338.6207039131894,-2.151075196046938,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/555S1,Regitec Solar BV,Mono-c-Si,0,550.0,516.3,2.58,,,72.0,14.06,50.32,13.33,41.62,0.0061864,-0.1242904,46.75,1.7462774608467626,14.070576694778433,4.255866662536055e-12,0.24096414683706707,320.3227457738034,-0.2795139996363158,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/555S3,Regitec Solar BV,Mono-c-Si,0,550.0,516.3,2.58,,,72.0,14.06,50.32,13.33,41.62,0.0061864,-0.1242904,46.75,1.7462774608467626,14.070576694778433,4.255866662536055e-12,0.24096414683706707,320.3227457738034,-0.2795139996363158,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/550S1,Regitec Solar BV,Mono-c-Si,0,555.0,521.1,2.58,,,72.0,13.98,50.18,13.26,41.47,0.0061512,-0.1239446,46.75,1.740391287220369,13.990054320066802,4.162722818130724e-12,0.24461283958705712,340.1212108054114,-0.4167214989071571,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/550S3,Regitec Solar BV,Mono-c-Si,0,555.0,521.1,2.58,,,72.0,13.98,50.18,13.26,41.47,0.0061512,-0.1239446,46.75,1.740391287220369,13.990054320066802,4.162722818130724e-12,0.24461283958705712,340.1212108054114,-0.4167214989071571,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/555S2,Regitec Solar BV,Mono-c-Si,1,555.0,523.2,2.58,,,72.0,14.06,50.32,13.33,41.64,0.0066082,-0.1263032,45.67,1.745781710224287,14.070571581873995,4.2208951993428155e-12,0.23940499629061907,318.4040285193678,-1.9887153032399136,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/545S1,Regitec Solar BV,Mono-c-Si,0,560.0,525.9,2.58,,,72.0,13.9,50.04,13.19,41.32,0.006116,-0.12359879999999998,46.75,1.7345046009127927,13.909515794870138,4.071005108901617e-12,0.24830061172754347,362.6999698826124,-0.5547580399219938,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/545S3,Regitec Solar BV,Mono-c-Si,0,560.0,525.9,2.58,,,72.0,13.9,50.04,13.19,41.32,0.006116,-0.12359879999999998,46.75,1.7345046009127927,13.909515794870138,4.071005108901617e-12,0.24830061172754347,362.6999698826124,-0.5547580399219938,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMH72/560S2,Regitec Solar BV,Mono-c-Si,1,560.0,528.0,2.58,,,72.0,14.13,50.67,13.35,41.96,0.0066411000000000005,-0.1271817,45.67,1.7612932025857513,14.144566804479558,4.463924836220995e-12,0.2372416350538642,230.12763807912785,-1.5603997318095821,-0.295,N,2025.7.3,6/23/2025,4.0,bootstrapping +Regitec Solar BV RMHT72/565S2,Regitec Solar BV,Mono-c-Si,1,565.0,532.9,2.58,,,72.0,14.19,50.87,13.41,42.15,0.0066692999999999995,-0.12768369999999998,45.67,1.768540257299144,14.204262196738261,4.50550168570882e-12,0.23510105761442798,233.91095219267189,-1.5203441072329433,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/575S1,Regitec Solar BV,Mono-c-Si,0,565.0,530.7,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0062964,-0.1266369,46.75,1.7809340531759348,14.322180385246373,4.444641249137364e-12,0.2383322251589539,280.00215823195833,-0.06156699738348913,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/575S3,Regitec Solar BV,Mono-c-Si,0,565.0,530.7,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0062964,-0.1266369,46.75,1.7809340531759348,14.322180385246373,4.444641249137364e-12,0.2383322251589539,280.00215823195833,-0.06156699738348913,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/570S1,Regitec Solar BV,Mono-c-Si,0,570.0,535.5,2.58,,,72.0,14.25,51.07,13.48,42.29,0.00627,-0.1261429,46.75,1.7750798691821021,14.263229195994615,4.499873202445819e-12,0.23707421294999817,255.367555453401,0.07928570683483975,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/570S2,Regitec Solar BV,Mono-c-Si,1,570.0,537.7,2.58,,,72.0,14.25,51.07,13.48,42.3,0.0066975,-0.1281857,45.67,1.774381696903528,14.263232117667393,4.449020625322995e-12,0.23637866281702605,254.56212084246516,-1.6612930589265038,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/570S3,Regitec Solar BV,Mono-c-Si,0,570.0,535.5,2.58,,,72.0,14.25,51.07,13.48,42.29,0.00627,-0.1261429,46.75,1.7750798691821021,14.263229195994615,4.499873202445819e-12,0.23707421294999817,255.367555453401,0.07928570683483975,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/580S1,Regitec Solar BV,Mono-c-Si,0,570.0,535.5,2.58,,,72.0,14.37,51.47,13.62,42.59,0.006322799999999999,-0.12713090000000002,46.75,1.7867926774030187,14.38111749766551,4.390785081810521e-12,0.2395758755119444,309.66548737906265,-0.20076371187909578,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/580S3,Regitec Solar BV,Mono-c-Si,0,570.0,535.5,2.58,,,72.0,14.37,51.47,13.62,42.59,0.006322799999999999,-0.12713090000000002,46.75,1.7867926774030187,14.38111749766551,4.390785081810521e-12,0.2395758755119444,309.66548737906265,-0.20076371187909578,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/575S2,Regitec Solar BV,Mono-c-Si,1,575.0,542.5,2.58,,,72.0,14.31,51.27,13.55,42.45,0.0067257,-0.12868770000000002,45.67,1.7802276624381466,14.322187719148816,4.393960979899902e-12,0.23764160098665335,279.0227834321701,-1.8005779489436264,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/565S1,Regitec Solar BV,Mono-c-Si,0,580.0,545.2,2.58,,,72.0,14.19,50.87,13.41,42.14,0.006243599999999999,-0.12564889999999998,46.75,1.769230227427163,14.204263735693246,4.556529642242076e-12,0.23580158325093617,234.58261739818397,0.22182746658152264,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Regitec Solar BV RMHT72/565S3,Regitec Solar BV,Mono-c-Si,0,580.0,545.2,2.58,,,72.0,14.19,50.87,13.41,42.14,0.006243599999999999,-0.12564889999999998,46.75,1.769230227427163,14.204263735693246,4.556529642242076e-12,0.23580158325093617,234.58261739818397,0.22182746658152264,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Reliance Industries Limited RNE655AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,655.0,623.8,3.03,,,66.0,16.86,49.0,16.01,40.9,0.0061876200000000004,-0.110103,45.48,1.5795129806163293,16.87475018003034,5.604452185518093e-13,0.18747955080640052,214.29604461535786,-8.737395045996733,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE660AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,660.0,628.7,3.03,,,66.0,16.96,49.0,16.12,41.0,0.00622432,-0.110103,45.48,1.5805889848265102,16.97327957287517,5.763032119847348e-13,0.1793849355114711,229.10138267831303,-8.569278671809093,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE665AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,665.0,633.5,3.03,,,66.0,17.05,49.1,16.22,41.0,0.006257350000000001,-0.11032770000000001,45.48,1.5818155966597534,17.062418586085563,5.577750643515431e-13,0.18461371239082142,253.46394289141332,-8.87006835035377,-0.2479,N,2025.7.3,6/23/2025,4.0,bootstrapping +Reliance Industries Limited RNE670AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,670.0,638.4,3.03,,,66.0,17.15,49.1,16.32,41.1,0.00629405,-0.11032770000000001,45.48,1.5833051831854974,17.161840138756197,5.777496870684332e-13,0.17663783688610088,255.8533278958629,-8.642299202207559,-0.2479,N,2025.7.3,6/23/2025,4.0,bootstrapping +Reliance Industries Limited RNE675AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,675.0,643.3,3.03,,,66.0,17.24,49.1,16.42,41.1,0.0063270800000000006,-0.11032770000000001,45.48,1.5827293730334338,17.250766806075752,5.748481076835312e-13,0.17571913913018541,281.36458836364324,-8.726025137667413,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE680AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,680.0,648.1,3.03,,,66.0,17.34,49.2,16.52,41.2,0.00636378,-0.11055240000000002,45.48,1.5860370718987238,17.3504205466583,5.793089783612153e-13,0.17395263896896937,289.4607026551049,-8.712032498422877,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE685AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,685.0,653.0,3.03,,,66.0,17.43,49.2,16.63,41.2,0.006396810000000001,-0.11055240000000002,45.48,1.5850778060327466,17.43856941425241,5.724512666600139e-13,0.17306070647528832,352.0016685228827,-8.851840660796073,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE690AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,690.0,657.9,3.03,,,66.0,17.53,49.3,16.71,41.3,0.006433510000000001,-0.1107771,45.48,1.589179253234004,17.539800515307306,5.850694155612843e-13,0.17132460620398673,306.4451463706657,-8.722561690426197,-0.2479,N,2025.7.3,6/23/2025,4.0,bootstrapping +Reliance Industries Limited RNE695AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,695.0,662.7,3.03,,,66.0,17.62,49.3,16.83,41.3,0.0064665400000000015,-0.1107771,45.48,1.5878410668956366,17.627182390135275,5.74247474632484e-13,0.17045940688508737,418.1748267655245,-8.916823232447983,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE700AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,700.0,667.6,3.03,,,66.0,17.72,49.4,16.91,41.4,0.00650324,-0.1110018,45.48,1.5919369433359356,17.7284144651479,5.868055996114319e-13,0.1687574645417328,355.38589478467463,-8.788092259499262,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE705AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,705.0,672.5,3.03,,,66.0,17.81,49.4,17.03,41.4,0.00653627,-0.1110018,45.48,1.590618792286563,17.815814584355426,5.761462117005286e-13,0.16791546886716105,514.3230055948175,-8.979454089118825,-0.2479,N,2025.7.3,6/23/2025,2.0,first_pass +Reliance Industries Limited RNE710AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,710.0,677.3,3.03,,,66.0,17.91,49.5,17.11,41.5,0.006572970000000001,-0.1112265,45.48,1.5947093671831771,17.917047436878136,5.886487553949146e-13,0.16624676183917642,422.49112086934434,-8.851622417467679,-0.2479,N,2025.7.3,6/23/2025,4.0,bootstrapping +Reliance Industries Limited RNE715AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,715.0,682.2,3.03,,,66.0,18.0,49.5,17.23,41.5,0.006606000000000001,-0.1112265,45.48,1.5934107487276246,18.004465746445433,5.781462384007364e-13,0.16542721049573908,666.784338888268,-9.040200680911758,-0.2479,N,2025.7.3,6/23/2025,4.0,bootstrapping +Reliance Industries Limited RNE720AA-66-BGG,Reliance Industries Limited,Mono-c-Si,0,720.0,687.1,3.03,,,66.0,18.1,49.6,17.31,41.6,0.006642700000000001,-0.11145120000000001,45.48,1.5974961572926547,18.10569935580623,5.905966335903302e-13,0.16379070602057413,520.1661172550417,-8.913277392728531,-0.2479,N,2025.7.3,6/23/2025,4.0,bootstrapping +Renesola America JC250S-24/Bbh,Renesola America,Mono-c-Si,0,250.0,229.0,1.6268799999999999,1.64,0.992,72.0,8.87,37.5,8.32,30.1,0.0077435099999999995,-0.154425,43.8,1.5883521078408782,8.876936323944994,4.903768444799739e-10,0.334373589522728,427.5888629058675,-9.588240424356277,-0.4273,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC250S-24/Bbh-b,Renesola America,Mono-c-Si,0,250.0,229.0,1.6268799999999999,1.64,0.992,72.0,8.87,37.5,8.32,30.1,0.0077435099999999995,-0.154425,43.8,1.5883521078408782,8.876936323944994,4.903768444799739e-10,0.334373589522728,427.5888629058675,-9.588240424356277,-0.4273,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC255S-24/Bbh,Renesola America,Mono-c-Si,0,255.0,233.7,1.6268799999999999,1.64,0.992,60.0,8.99,37.6,8.44,30.2,0.007848270000000001,-0.1548368,43.8,1.5924542571450906,8.996228490603903,4.965117605747809e-10,0.32805004838408824,473.4969329716035,-9.597590887563674,-0.4273,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC255S-24/Bbh-b,Renesola America,Mono-c-Si,0,255.0,233.7,1.6268799999999999,1.64,0.992,60.0,8.99,37.6,8.44,30.2,0.007848270000000001,-0.1548368,43.8,1.5924542571450906,8.996228490603903,4.965117605747809e-10,0.32805004838408824,473.4969329716035,-9.597590887563674,-0.4273,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC260M-24/Bbs,Renesola America,Multi-c-Si,0,260.0,235.6,1.6268799999999999,1.64,0.992,60.0,8.95,37.6,8.53,30.5,0.0045824,-0.1244936,45.2,1.5598370368321537,8.95000244389574,3.041705350567509e-10,0.2729321704374888,999999.8298941366,8.731997569631412,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC260M-24/Bbs-b,Renesola America,Multi-c-Si,0,260.0,235.6,1.6268799999999999,1.64,0.992,60.0,8.95,37.6,8.53,30.5,0.0045824,-0.1244936,45.2,1.5598370368321537,8.95000244389574,3.041705350567509e-10,0.2729321704374888,999999.8298941366,8.731997569631412,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC260M-24/Bzs,Renesola America,Multi-c-Si,0,260.0,235.6,1.6268799999999999,1.64,0.992,60.0,8.95,37.6,8.53,30.5,0.0045824,-0.1244936,45.2,1.5598370368321537,8.95000244389574,3.041705350567509e-10,0.2729321704374888,999999.8298941366,8.731997569631412,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC260M-24/Bzs-b,Renesola America,Multi-c-Si,0,260.0,235.6,1.6268799999999999,1.64,0.992,60.0,8.95,37.6,8.53,30.5,0.0045824,-0.1244936,45.2,1.5598370368321537,8.95000244389574,3.041705350567509e-10,0.2729321704374888,999999.8298941366,8.731997569631412,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC265M-24/Bbs,Renesola America,Multi-c-Si,0,265.0,240.2,1.6268799999999999,1.64,0.992,60.0,9.03,37.7,8.66,30.6,0.00462336,-0.12482470000000002,45.2,1.5695078678372625,9.030197729283108,3.339346869737131e-10,0.23954015981688906,10939.494672809253,9.476509238819247,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC265M-24/Bbs-b,Renesola America,Multi-c-Si,0,265.0,240.2,1.6268799999999999,1.64,0.992,60.0,9.03,37.7,8.66,30.6,0.00462336,-0.12482470000000002,45.2,1.5695078678372625,9.030197729283108,3.339346869737131e-10,0.23954015981688906,10939.494672809253,9.476509238819247,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC265M-24/Bzs,Renesola America,Multi-c-Si,0,265.0,240.2,1.6268799999999999,1.64,0.992,60.0,9.03,37.7,8.66,30.6,0.00462336,-0.12482470000000002,45.2,1.5695078678372625,9.030197729283108,3.339346869737131e-10,0.23954015981688906,10939.494672809253,9.476509238819247,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC265M-24/Bzs-b,Renesola America,Multi-c-Si,0,265.0,240.2,1.6268799999999999,1.64,0.992,60.0,9.03,37.7,8.66,30.6,0.00462336,-0.12482470000000002,45.2,1.5695078678372625,9.030197729283108,3.339346869737131e-10,0.23954015981688906,10939.494672809253,9.476509238819247,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC270M-24/Bbs,Renesola America,Multi-c-Si,0,270.0,244.9,1.6268799999999999,1.64,0.992,60.0,9.1,38.1,8.71,31.0,0.0046592000000000005,-0.12614910000000001,45.2,1.5860326901986774,9.100002199290724,3.359922555009936e-10,0.24156868406386137,999996.3282012446,9.461386662506515,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC270M-24/Bbs-b,Renesola America,Multi-c-Si,0,270.0,244.9,1.6268799999999999,1.64,0.992,60.0,9.1,38.1,8.71,31.0,0.0046592000000000005,-0.12614910000000001,45.2,1.5860326901986774,9.100002199290724,3.359922555009936e-10,0.24156868406386137,999996.3282012446,9.461386662506515,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC270M-24/Bzs,Renesola America,Multi-c-Si,0,270.0,244.9,1.6268799999999999,1.64,0.992,60.0,9.1,38.1,8.71,31.0,0.0046592000000000005,-0.12614910000000001,45.2,1.5860326901986774,9.100002199290724,3.359922555009936e-10,0.24156868406386137,999996.3282012446,9.461386662506515,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC270M-24/Bzs-b,Renesola America,Multi-c-Si,0,270.0,244.9,1.6268799999999999,1.64,0.992,60.0,9.1,38.1,8.71,31.0,0.0046592000000000005,-0.12614910000000001,45.2,1.5860326901986774,9.100002199290724,3.359922555009936e-10,0.24156868406386137,999996.3282012446,9.461386662506515,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC290F-24/Abh-b,Renesola America,Mono-c-Si,0,290.0,265.5,1.9403519999999999,1.956,0.992,72.0,8.45,45.2,8.15,35.6,0.00737685,-0.1861336,43.8,1.908416464192246,8.450003350186503,4.3730234999950954e-10,0.3962237854512717,999998.438999124,-10.090699032294843,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC290S-24/Abh,Renesola America,Mono-c-Si,0,290.0,265.5,1.9403519999999999,1.956,0.992,72.0,8.45,45.2,8.15,35.6,0.00737685,-0.1861336,43.8,1.908416464192246,8.450003350186503,4.3730234999950954e-10,0.3962237854512717,999998.438999124,-10.090699032294843,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC295M-24/Abh,Renesola America,Multi-c-Si,0,295.0,270.0,1.9403519999999999,1.956,0.992,72.0,8.62,44.7,8.13,36.3,0.0074994,-0.18228660000000002,44.3,1.8853554990988999,8.62279860449308,4.3337140448319283e-10,0.352998275347719,1087.272973517436,-9.4008113265264,-0.4194,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC295M-24/Abh-b,Renesola America,Multi-c-Si,0,295.0,270.0,1.9403519999999999,1.956,0.992,72.0,8.62,44.7,8.13,36.3,0.0074994,-0.18228660000000002,44.3,1.8853554990988999,8.62279860449308,4.3337140448319283e-10,0.352998275347719,1087.272973517436,-9.4008113265264,-0.4194,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC295S-24/Abh,Renesola America,Mono-c-Si,0,295.0,270.1,1.9403519999999999,1.956,0.992,72.0,8.52,45.3,8.27,35.7,0.00743796,-0.18654539999999997,43.8,1.920157192030025,8.520002911147108,4.837721172993619e-10,0.34148207734253955,999999.2477610876,-9.410914640416221,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC295S-24/Abh-b,Renesola America,Mono-c-Si,0,295.0,270.1,1.9403519999999999,1.956,0.992,72.0,8.52,45.3,8.27,35.7,0.00743796,-0.18654539999999997,43.8,1.920157192030025,8.520002911147108,4.837721172993619e-10,0.34148207734253955,999999.2477610876,-9.410914640416221,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC300S-24/Abh,Renesola America,Mono-c-Si,0,300.0,274.8,1.9403519999999999,1.956,0.992,72.0,8.59,45.4,8.38,35.8,0.007499070000000001,-0.18695720000000002,43.8,1.9307853461370723,8.590002496452087,5.273512812072718e-10,0.29046070764046794,999999.269468859,-8.834457217866598,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC300S-24/Abh-b,Renesola America,Mono-c-Si,0,300.0,274.8,1.9403519999999999,1.956,0.992,72.0,8.59,45.4,8.38,35.8,0.007499070000000001,-0.18695720000000002,43.8,1.9307853461370723,8.590002496452087,5.273512812072718e-10,0.29046070764046794,999999.269468859,-8.834457217866598,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC305S-24/Abh-b,Renesola America,Mono-c-Si,0,305.0,279.5,1.9403519999999999,1.956,0.992,72.0,8.64,45.6,8.5,35.9,0.007542720000000001,-0.1877808,43.8,1.9456505148213692,8.640002306949736,5.72794603651158e-10,0.26685731944196045,999999.2431372883,-8.263178310251279,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC310M-24/Abs,Renesola America,Multi-c-Si,0,310.0,280.9,1.9403519999999999,1.956,0.992,72.0,8.8,45.0,8.38,37.0,0.004505600000000001,-0.14899500000000002,45.2,1.878025507543551,8.800002401915034,3.453063882306456e-10,0.2728420951274145,999999.9191857193,10.000292555794193,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC310M-24/Abs-b,Renesola America,Multi-c-Si,0,310.0,280.9,1.9403519999999999,1.956,0.992,72.0,8.8,45.0,8.38,37.0,0.004505600000000001,-0.14899500000000002,45.2,1.878025507543551,8.800002401915034,3.453063882306456e-10,0.2728420951274145,999999.9191857193,10.000292555794193,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC310M-24/Azs,Renesola America,Multi-c-Si,0,310.0,280.9,1.9403519999999999,1.956,0.992,72.0,8.8,45.0,8.38,37.0,0.004505600000000001,-0.14899500000000002,45.2,1.878025507543551,8.800002401915034,3.453063882306456e-10,0.2728420951274145,999999.9191857193,10.000292555794193,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC310M-24/Azs-b,Renesola America,Multi-c-Si,0,310.0,280.9,1.9403519999999999,1.956,0.992,72.0,8.8,45.0,8.38,37.0,0.004505600000000001,-0.14899500000000002,45.2,1.878025507543551,8.800002401915034,3.453063882306456e-10,0.2728420951274145,999999.9191857193,10.000292555794193,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC310S-24/Abh,Renesola America,Mono-c-Si,0,310.0,284.2,1.9403519999999999,1.956,0.992,72.0,8.87,45.8,8.59,36.1,0.0077435099999999995,-0.18860439999999998,43.8,1.9389410635872006,8.870003099177524,4.890918132748224e-10,0.3491824001937885,999999.1980655137,-9.626430827314072,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC310S-24/Abh-b,Renesola America,Mono-c-Si,0,310.0,284.2,1.9403519999999999,1.956,0.992,72.0,8.87,45.8,8.59,36.1,0.0077435099999999995,-0.18860439999999998,43.8,1.9389410635872006,8.870003099177524,4.890918132748224e-10,0.3491824001937885,999999.1980655137,-9.626430827314072,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC315M-24/Abs,Renesola America,Multi-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.88,45.4,8.45,37.3,0.004546560000000001,-0.15031940000000002,45.2,1.890188969508337,8.908922922500643,3.3007068800152947e-10,0.29511058469398654,999999.9403540076,9.493705519802074,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC315M-24/Abs-b,Renesola America,Multi-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.88,45.4,8.45,37.3,0.004546560000000001,-0.15031940000000002,45.2,1.890188969508337,8.908922922500643,3.3007068800152947e-10,0.29511058469398654,999999.9403540076,9.493705519802074,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC315M-24/Azs,Renesola America,Multi-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.88,45.4,8.45,37.3,0.004546560000000001,-0.15031940000000002,45.2,1.890188969508337,8.908922922500643,3.3007068800152947e-10,0.29511058469398654,999999.9403540076,9.493705519802074,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC315M-24/Azs-b,Renesola America,Multi-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.88,45.4,8.45,37.3,0.004546560000000001,-0.15031940000000002,45.2,1.890188969508337,8.908922922500643,3.3007068800152947e-10,0.29511058469398654,999999.9403540076,9.493705519802074,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC315S-24/Abh,Renesola America,Mono-c-Si,0,315.0,288.9,1.9403519999999999,1.956,0.992,72.0,8.94,46.0,8.68,36.3,0.00780462,-0.189428,43.8,1.9514527391664942,8.94000288176861,5.17686288070983e-10,0.3221498104009905,999999.2319109418,-9.266287725093898,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC315S-24/Abh-b,Renesola America,Mono-c-Si,0,315.0,288.9,1.9403519999999999,1.956,0.992,72.0,8.94,46.0,8.68,36.3,0.00780462,-0.189428,43.8,1.9514527391664942,8.94000288176861,5.17686288070983e-10,0.3221498104009905,999999.2319109418,-9.266287725093898,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC320M-24/Abs,Renesola America,Multi-c-Si,0,320.0,290.2,1.9403519999999999,1.956,0.992,72.0,9.0,45.6,8.56,37.4,0.004608,-0.15098160000000002,45.2,1.8968636611758771,9.026348184467937,3.274978614232093e-10,0.30134295057317834,999999.9689954057,9.308872987566595,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC320M-24/Abs-b,Renesola America,Multi-c-Si,0,320.0,290.2,1.9403519999999999,1.956,0.992,72.0,9.0,45.6,8.56,37.4,0.004608,-0.15098160000000002,45.2,1.8968636611758771,9.026348184467937,3.274978614232093e-10,0.30134295057317834,999999.9689954057,9.308872987566595,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC320M-24/Azs,Renesola America,Multi-c-Si,0,320.0,290.2,1.9403519999999999,1.956,0.992,72.0,9.0,45.6,8.56,37.4,0.004608,-0.15098160000000002,45.2,1.8968636611758771,9.026348184467937,3.274978614232093e-10,0.30134295057317834,999999.9689954057,9.308872987566595,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC320M-24/Azs-b,Renesola America,Multi-c-Si,0,320.0,290.2,1.9403519999999999,1.956,0.992,72.0,9.0,45.6,8.56,37.4,0.004608,-0.15098160000000002,45.2,1.8968636611758771,9.026348184467937,3.274978614232093e-10,0.30134295057317834,999999.9689954057,9.308872987566595,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC320S-24/Abh,Renesola America,Mono-c-Si,0,320.0,293.6,1.9403519999999999,1.956,0.992,72.0,9.02,46.1,8.77,36.5,0.00787446,-0.1898398,43.8,1.9606213076822478,9.020002644274438,5.541890798872437e-10,0.29298153708208585,999999.2955476912,-8.828579260011223,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC320S-24/Abh-b,Renesola America,Mono-c-Si,0,320.0,293.6,1.9403519999999999,1.956,0.992,72.0,9.02,46.1,8.77,36.5,0.00787446,-0.1898398,43.8,1.9606213076822478,9.020002644274438,5.541890798872437e-10,0.29298153708208585,999999.2955476912,-8.828579260011223,-0.4273,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC325M-24/Abs,Renesola America,Multi-c-Si,0,325.0,294.8,1.9403519999999999,1.956,0.992,72.0,9.09,45.9,8.67,37.5,0.00465408,-0.1519749,45.2,1.9112693038220585,9.090002646553948,3.378957076668193e-10,0.2910387709418236,999999.8668169104,9.52100545859652,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC325M-24/Abs-b,Renesola America,Multi-c-Si,0,325.0,294.8,1.9403519999999999,1.956,0.992,72.0,9.09,45.9,8.67,37.5,0.00465408,-0.1519749,45.2,1.9112693038220585,9.090002646553948,3.378957076668193e-10,0.2910387709418236,999999.8668169104,9.52100545859652,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC325M-24/Azs,Renesola America,Multi-c-Si,0,325.0,294.8,1.9403519999999999,1.956,0.992,72.0,9.09,45.9,8.67,37.5,0.00465408,-0.1519749,45.2,1.9112693038220585,9.090002646553948,3.378957076668193e-10,0.2910387709418236,999999.8668169104,9.52100545859652,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC325M-24/Azs-b,Renesola America,Multi-c-Si,0,325.0,294.8,1.9403519999999999,1.956,0.992,72.0,9.09,45.9,8.67,37.5,0.00465408,-0.1519749,45.2,1.9112693038220585,9.090002646553948,3.378957076668193e-10,0.2910387709418236,999999.8668169104,9.52100545859652,-0.4495,N,2025.7.3,6/23/2025,2.0,first_pass +Renesola America JC330M-24/Abs,Renesola America,Multi-c-Si,0,330.0,299.5,1.9403519999999999,1.956,0.992,72.0,9.35,46.4,8.78,37.6,0.0047872,-0.1536304,45.2,1.927156931597427,9.357428708046639,3.2347983835138346e-10,0.35573596785964084,447.740299849167,8.921381999717653,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC330M-24/Abs-b,Renesola America,Multi-c-Si,0,330.0,299.5,1.9403519999999999,1.956,0.992,72.0,9.35,46.4,8.78,37.6,0.0047872,-0.1536304,45.2,1.927156931597427,9.357428708046639,3.2347983835138346e-10,0.35573596785964084,447.740299849167,8.921381999717653,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC330M-24/Azs,Renesola America,Multi-c-Si,0,330.0,299.5,1.9403519999999999,1.956,0.992,72.0,9.35,46.4,8.78,37.6,0.0047872,-0.1536304,45.2,1.927156931597427,9.357428708046639,3.2347983835138346e-10,0.35573596785964084,447.740299849167,8.921381999717653,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC330M-24/Azs-b,Renesola America,Multi-c-Si,0,330.0,299.5,1.9403519999999999,1.956,0.992,72.0,9.35,46.4,8.78,37.6,0.0047872,-0.1536304,45.2,1.927156931597427,9.357428708046639,3.2347983835138346e-10,0.35573596785964084,447.740299849167,8.921381999717653,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC335M-24/Abs,Renesola America,Multi-c-Si,0,335.0,304.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.6,8.89,37.7,0.0048384000000000005,-0.1542926,45.2,1.931809040892956,9.455957772427425,3.1311660256001817e-10,0.36184813381215214,573.9503782397617,8.53507324140866,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC335M-24/Abs-b,Renesola America,Multi-c-Si,0,335.0,304.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.6,8.89,37.7,0.0048384000000000005,-0.1542926,45.2,1.931809040892956,9.455957772427425,3.1311660256001817e-10,0.36184813381215214,573.9503782397617,8.53507324140866,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC335M-24/Azs,Renesola America,Multi-c-Si,0,335.0,304.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.6,8.89,37.7,0.0048384000000000005,-0.1542926,45.2,1.931809040892956,9.455957772427425,3.1311660256001817e-10,0.36184813381215214,573.9503782397617,8.53507324140866,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Renesola America JC335M-24/Azs-b,Renesola America,Multi-c-Si,0,335.0,304.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.6,8.89,37.7,0.0048384000000000005,-0.1542926,45.2,1.931809040892956,9.455957772427425,3.1311660256001817e-10,0.36184813381215214,573.9503782397617,8.53507324140866,-0.4495,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8V415M-DG,Resun Solar Inc,Mono-c-Si,1,415.0,390.2,1.95,,,54.0,13.91,38.15,13.09,31.71,0.0061204,-0.0942305,45.88,1.3379335452728558,13.927669764702765,5.641131811047808e-12,0.16990252550956617,133.75074174870036,2.1845735619470235,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8V420M-DG,Resun Solar Inc,Mono-c-Si,1,420.0,395.0,1.95,,,54.0,14.0,38.3,13.19,31.85,0.0061600000000000005,-0.094601,45.88,1.3427893169062775,14.01645740473914,5.636436938579845e-12,0.16818184476124923,143.06908470849672,2.1185279158454757,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8V425M-DG,Resun Solar Inc,Mono-c-Si,1,425.0,399.9,1.95,,,54.0,14.09,38.45,13.29,31.99,0.0061995999999999996,-0.09497150000000001,45.88,1.3476503779483644,14.10526437897474,5.6323856829611884e-12,0.16648548763550092,153.67677461004033,2.0538743533664987,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8V430M-DG,Resun Solar Inc,Mono-c-Si,1,430.0,404.7,1.95,,,54.0,14.18,38.6,13.38,32.15,0.0062392,-0.095342,45.88,1.3533853576943013,14.194761100562598,5.7276940274885746e-12,0.1630845943221695,156.66444002031292,2.1399805035062127,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8V435M-DG,Resun Solar Inc,Mono-c-Si,1,435.0,409.5,1.95,,,54.0,14.27,38.75,13.47,32.3,0.006278799999999999,-0.0957125,45.88,1.3589178015496697,14.284324471424586,5.79932946812726e-12,0.16057612298340854,159.96550330834953,2.189843953671932,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8V440M-DG,Resun Solar Inc,Mono-c-Si,1,440.0,414.3,1.95,,,54.0,14.36,38.9,13.56,32.45,0.0063184,-0.096083,45.88,1.3644508252950611,14.373896540291671,5.8713963787076446e-12,0.1581009751507436,163.37375789090012,2.239413898797012,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8K460M-DG,Resun Solar Inc,Mono-c-Si,1,460.0,432.5,2.16,,,60.0,13.89,42.3,13.09,35.15,0.006111599999999999,-0.10448099999999999,45.88,1.4823024185536757,13.906185295974353,5.51675095119523e-12,0.18952568782481674,162.6483576549495,2.0031462986533355,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8K465M-DG,Resun Solar Inc,Mono-c-Si,1,465.0,437.4,2.16,,,60.0,13.98,42.45,13.18,35.3,0.0061512,-0.10485150000000001,45.88,1.487806317907684,13.995735672054007,5.581112033991436e-12,0.18678997577529505,165.94930677578586,2.0447988758948887,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8K470M-DG,Resun Solar Inc,Mono-c-Si,1,470.0,442.2,2.16,,,60.0,14.06,42.6,13.26,35.45,0.0061864,-0.10522200000000001,45.88,1.4933406160485618,14.075328218238365,5.6447431996506445e-12,0.1842207008130209,168.97874368645677,2.0907854650610065,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8K475M-DG,Resun Solar Inc,Mono-c-Si,1,475.0,447.0,2.16,,,60.0,14.15,42.75,13.35,35.6,0.006226000000000001,-0.10559249999999999,45.88,1.4988462627489352,14.164894600303256,5.7098749778501964e-12,0.18155543516995426,172.47924478037243,2.13209317869535,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8K480M-DG,Resun Solar Inc,Mono-c-Si,1,480.0,451.8,2.16,,,60.0,14.23,42.9,13.43,35.75,0.0062612,-0.105963,45.88,1.5043817761098135,14.244501967930027,5.7742256221406156e-12,0.1790498685757852,175.69199223256382,2.1776269524467216,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8K485M-DG,Resun Solar Inc,Mono-c-Si,1,485.0,456.7,2.16,,,60.0,14.31,43.05,13.51,35.9,0.0062964,-0.1063335,45.88,1.5099177622184758,14.32411634431588,5.838921813291211e-12,0.1765740140839495,178.99635260389448,2.2229100495114307,-0.303,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I550M-DG,Resun Solar Inc,Mono-c-Si,1,550.0,517.5,2.58,,,72.0,13.85,50.75,13.04,42.17,0.0059555,-0.1273825,46.3,1.7594000806750008,13.86786082206314,4.034759405713287e-12,0.23158338378895252,179.57907298726616,-2.140798539294466,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I555M-DG,Resun Solar Inc,Mono-c-Si,1,555.0,522.3,2.58,,,72.0,13.92,50.9,13.11,42.34,0.005985599999999999,-0.127759,46.3,1.765259340319987,13.937384555576473,4.100149938609538e-12,0.22716567394369652,181.89399039445368,-2.0526180832321037,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I560M-DG,Resun Solar Inc,Mono-c-Si,1,560.0,527.2,2.58,,,72.0,13.99,51.05,13.19,42.47,0.0060157,-0.12813549999999999,46.3,1.7697015394050446,14.006315728158489,4.075093124885349e-12,0.2262804767103202,194.02528860449345,-2.147128792796654,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I565M-DG,Resun Solar Inc,Mono-c-Si,1,565.0,532.0,2.58,,,72.0,14.06,51.2,13.26,42.62,0.0060458,-0.12851200000000002,46.3,1.7751615240633025,14.075960963011559,4.114055380766082e-12,0.22365946580173257,197.0214482686379,-2.111674679628127,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I570M-DG,Resun Solar Inc,Mono-c-Si,1,570.0,536.8,2.58,,,72.0,14.13,51.35,13.33,42.77,0.0060758999999999995,-0.12888850000000002,46.3,1.780622079809679,14.145611461033042,4.153204787743619e-12,0.22106596222898653,200.08774628586806,-2.076360544924611,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I575M-DG,Resun Solar Inc,Mono-c-Si,1,575.0,541.6,2.58,,,72.0,14.2,51.5,13.4,42.92,0.006105999999999999,-0.129265,46.3,1.7860832022277213,14.215267161002688,4.192541170187859e-12,0.21849953471713063,203.22660403242142,-2.0411846226964285,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Resun Solar Inc RS8I580M-DG,Resun Solar Inc,Mono-c-Si,1,580.0,546.5,2.58,,,72.0,14.27,51.65,13.47,43.07,0.006136099999999999,-0.1296415,46.3,1.7915448577069255,14.284927981335635,4.232062442979726e-12,0.21595976618099955,206.44089713978542,-2.006150359004415,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP200P,Risen Energy Co Ltd,Multi-c-Si,0,200.0,175.0,1.6268799999999999,1.64,0.992,60.0,7.65,36.5,6.98,28.6,0.0045899999999999995,-0.14162,47.0,1.636097477913863,7.679522075738591,1.5110330450897015e-09,0.4695580777191502,121.67575169367899,6.886198839762284,-0.518,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP210M,Risen Energy Co Ltd,Mono-c-Si,0,210.0,184.9,1.6268799999999999,1.64,0.992,60.0,7.88,36.5,7.24,29.0,0.0066191999999999996,-0.127385,45.6,1.6827700460916348,7.899396568538209,2.912823716774328e-09,0.3785864470719359,153.80366824443865,24.913777726338097,-0.534,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP210P,Risen Energy Co Ltd,Multi-c-Si,0,210.0,184.0,1.6268799999999999,1.64,0.992,60.0,7.88,36.5,7.24,29.0,0.0047279999999999996,-0.14162,47.0,1.6440166525974287,7.9009730590820615,1.744423394978033e-09,0.3891464581927318,146.2102149589025,7.871235927772802,-0.518,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP220M,Risen Energy Co Ltd,Mono-c-Si,0,220.0,193.9,1.6268799999999999,1.64,0.992,60.0,8.1,37.0,7.45,29.5,0.006804000000000001,-0.12913,45.6,1.7084674825536246,8.118436683997393,3.0989471990792643e-09,0.35679731129838216,156.75597482978014,25.266885779428844,-0.534,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP220P,Risen Energy Co Ltd,Multi-c-Si,0,220.0,193.0,1.6268799999999999,1.64,0.992,60.0,8.1,37.0,7.45,29.5,0.00486,-0.14356,47.0,1.669193682170216,8.119983288568996,1.8591365213345646e-09,0.3672247124031842,148.85045210418573,8.18851799257661,-0.518,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-230M,Risen Energy Co Ltd,Mono-c-Si,0,230.0,207.7,1.6268799999999999,1.64,0.992,60.0,8.22,37.0,7.73,29.8,0.0054005400000000005,-0.134606,43.5,1.6182581815419963,8.223003337004089,9.618260703543365e-10,0.3274397432724851,896.1892627380435,9.148041308793484,-0.4902,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-230P,Risen Energy Co Ltd,Multi-c-Si,0,230.0,208.3,1.6268799999999999,1.64,0.992,60.0,8.22,37.0,7.73,29.8,0.00529368,-0.133792,43.4,1.6020090408028913,8.223435484811613,7.622877288059839e-10,0.3316819105033072,793.6079379237717,7.778667086448728,-0.4808,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP230M,Risen Energy Co Ltd,Mono-c-Si,0,230.0,206.3,1.6268799999999999,1.64,0.992,60.0,8.22,37.0,7.73,29.8,0.0031236000000000002,-0.13541999999999998,45.2,1.5629322374998404,8.224518305420718,4.2727674136750104e-10,0.34195452083542277,622.1065723487714,1.9040672764844033,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP230P,Risen Energy Co Ltd,Multi-c-Si,0,230.0,202.0,1.6268799999999999,1.64,0.992,60.0,8.22,37.0,7.73,29.8,0.004685400000000001,-0.14356,47.1,1.6517497492136581,8.222145727694341,1.5309940693244991e-09,0.3187495680070468,1221.090903011992,6.327574967106931,-0.516,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-235M,Risen Energy Co Ltd,Mono-c-Si,0,235.0,212.3,1.6268799999999999,1.64,0.992,60.0,8.27,37.1,7.83,30.0,0.005433389999999999,-0.1349698,43.5,1.622488634444628,8.2904901112253,9.72643810045479e-10,0.3077868774641761,999999.9784912755,9.1599582098218,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-235P,Risen Energy Co Ltd,Multi-c-Si,0,235.0,212.9,1.6268799999999999,1.64,0.992,60.0,8.28,37.1,7.84,30.0,0.00533232,-0.13415359999999998,43.4,1.605798723934485,8.296906166242275,7.674950798913362e-10,0.311789010040757,999999.9387965176,7.743181800076485,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-240M,Risen Energy Co Ltd,Mono-c-Si,0,240.0,217.0,1.6268799999999999,1.64,0.992,60.0,8.33,37.2,7.95,30.2,0.00547281,-0.13533360000000003,43.5,1.6386346095554711,8.330002036273896,1.151767500473308e-09,0.24411054100753454,999999.5400340889,10.627064996332146,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-240P,Risen Energy Co Ltd,Multi-c-Si,0,240.0,217.5,1.6268799999999999,1.64,0.992,60.0,8.33,37.2,7.96,30.2,0.00536452,-0.1345152,43.4,1.622300076411944,8.330002040690657,9.164192763692819e-10,0.2447041020941577,999998.8009056518,9.269546890234192,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd SYP240M,Risen Energy Co Ltd,Mono-c-Si,0,240.0,215.5,1.6268799999999999,1.64,0.992,60.0,8.33,37.2,7.95,30.2,0.0031654,-0.13615200000000002,45.2,1.57959172455617,8.33000222597443,4.92991091653504e-10,0.2670408840450242,999999.5510352433,2.9550523968331444,-0.478,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd SYP240P,Risen Energy Co Ltd,Multi-c-Si,0,240.0,211.1,1.6268799999999999,1.64,0.992,60.0,8.33,37.2,7.95,30.2,0.0047481,-0.14433600000000002,47.1,1.6745888047408897,8.330001921142873,1.8752020725509115e-09,0.23014709723387972,999999.5328461055,7.973449425196827,-0.516,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-245M,Risen Energy Co Ltd,Mono-c-Si,0,245.0,221.6,1.6268799999999999,1.64,0.992,60.0,8.48,37.4,8.09,30.3,0.005571359999999999,-0.1360612,43.5,1.6454647925073145,8.480002133998923,1.1409165215906382e-09,0.2512939983679805,999999.595623145,10.381362768659399,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-245P,Risen Energy Co Ltd,Multi-c-Si,0,245.0,222.2,1.6268799999999999,1.64,0.992,60.0,8.34,37.3,8.09,30.3,0.00537096,-0.1348768,43.4,1.639394471136732,8.34000128983171,1.0963884812387607e-09,0.15449518250546437,999998.2806441936,10.863628119802554,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-250M,Risen Energy Co Ltd,Mono-c-Si,0,250.0,226.3,1.6268799999999999,1.64,0.992,60.0,8.59,37.5,8.25,30.4,0.00564363,-0.13642500000000002,43.5,1.6558620806685178,8.590001827158908,1.254888536038874e-09,0.21241263978136926,999999.9763823556,11.123774311509823,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-250P,Risen Energy Co Ltd,Multi-c-Si,0,250.0,226.9,1.6268799999999999,1.64,0.992,60.0,8.9,37.3,8.26,30.3,0.005731600000000001,-0.1348768,43.4,1.6351523458570365,8.913414927823775,1.078854240839072e-09,0.27050983323686917,179.46709750230121,10.198735755243074,-0.4808,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP250M,Risen Energy Co Ltd,Mono-c-Si,0,250.0,224.8,1.6268799999999999,1.64,0.992,60.0,8.89,37.5,8.22,30.4,0.0033782,-0.13724999999999998,45.2,1.6049856598451933,8.907989476456203,6.161866634939442e-10,0.29086071193390517,143.73692811558948,4.35913720310453,-0.478,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP250P,Risen Energy Co Ltd,Multi-c-Si,0,250.0,222.2,1.9403519999999999,1.956,0.992,72.0,8.05,43.8,7.2,34.7,0.005393500000000001,-0.162936,46.2,1.9411477260253385,8.098750605169531,1.1989399465070406e-09,0.4873639243314262,80.47654401192966,8.972280879138747,-0.482,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-255M,Risen Energy Co Ltd,Mono-c-Si,0,255.0,227.1,1.6367999999999998,1.65,0.992,60.0,8.64,37.5,8.39,30.5,0.0044063999999999996,-0.12187500000000001,48.5,1.565466823974605,8.640001497715089,3.413483753785732e-10,0.17328263064910113,999995.8472120165,12.142788231898534,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-255P,Risen Energy Co Ltd,Multi-c-Si,0,255.0,230.6,1.64,,,60.0,8.96,37.6,8.42,30.3,0.0035840000000000004,-0.1196808,46.7,1.4983657486884345,8.968522075825112,1.120443005090598e-10,0.33875205903127337,356.15955247783944,4.547519383626861,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-260M,Risen Energy Co Ltd,Mono-c-Si,0,260.0,231.7,1.6367999999999998,1.65,0.992,60.0,8.77,37.5,8.53,30.5,0.0044727,-0.12187500000000001,48.5,1.5666712769386528,8.770001401053007,3.529244568565812e-10,0.15969687991000178,999998.9970929518,12.30958062967543,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-260P,Risen Energy Co Ltd,Multi-c-Si,0,260.0,235.2,1.64,,,60.0,9.04,37.8,8.5,30.6,0.003616,-0.1203174,46.7,1.5097016229661153,9.047957687741794,1.1956771973126885e-10,0.3184051413724111,361.7109416408519,5.019820054041917,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP260M,Risen Energy Co Ltd,Mono-c-Si,0,260.0,226.0,1.9403519999999999,1.956,0.992,72.0,8.1,44.0,7.47,34.8,0.003969,-0.18832,46.7,2.0364759666164343,8.116757011997022,3.2767492183794073e-09,0.46536148578660264,224.94654719565787,2.767767799404031,-0.558,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP260P,Risen Energy Co Ltd,Multi-c-Si,0,260.0,231.3,1.9403519999999999,1.956,0.992,72.0,8.1,44.0,7.47,34.8,0.005427,-0.16368,46.2,1.9138677661859869,8.121045874586908,8.178632056982143e-10,0.4977299153841524,191.56312221623747,5.491763734251198,-0.482,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-265M,Risen Energy Co Ltd,Mono-c-Si,0,265.0,236.3,1.6367999999999998,1.65,0.992,60.0,9.29,37.7,8.64,30.7,0.0047379,-0.12252500000000002,48.5,1.5725589791225576,9.30486603443936,3.520213215396248e-10,0.271132922163078,169.43490165180356,11.839507582734672,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-265P,Risen Energy Co Ltd,Multi-c-Si,0,265.0,239.8,1.64,,,60.0,9.12,38.0,8.58,30.9,0.0036479999999999998,-0.120954,46.7,1.5210278680013423,9.127405510711007,1.2746032226794669e-10,0.2984531550745149,367.5496686280398,5.48584918002194,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-270M,Risen Energy Co Ltd,Mono-c-Si,0,270.0,240.9,1.6367999999999998,1.65,0.992,60.0,9.38,37.9,8.74,30.9,0.0047838,-0.123175,48.5,1.5804053823989082,9.393372664121959,3.5350652933465676e-10,0.26512817143595957,185.9691140655747,11.783934153063756,-0.447,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-270P,Risen Energy Co Ltd,Multi-c-Si,0,270.0,244.5,1.64,,,60.0,9.2,38.2,8.66,31.2,0.00368,-0.12159060000000003,46.7,1.5323448290836896,9.206866126308057,1.3573311526857073e-10,0.27888459236082785,373.68063948802217,5.945751253948717,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP270M,Risen Energy Co Ltd,Mono-c-Si,0,270.0,235.0,1.9403519999999999,1.956,0.992,72.0,8.2,44.5,7.71,35.0,0.004018,-0.19046,46.7,2.0315120537762694,8.212440410414679,2.5194590340215035e-09,0.49597339741817764,999999.9828909653,0.4134241093728532,-0.558,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd SYP270P,Risen Energy Co Ltd,Multi-c-Si,0,270.0,237.6,1.9403519999999999,1.956,0.992,72.0,8.2,44.5,7.71,35.0,0.0038539999999999994,-0.17622000000000002,46.1,1.9731570533115592,8.200026512507836,1.3161075675097126e-09,0.5110035835830776,158105.02917367703,3.0127820654950006,-0.532,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-275M,Risen Energy Co Ltd,Mono-c-Si,0,275.0,249.6,1.64,,,60.0,9.36,38.5,8.88,31.0,0.0030888,-0.1160005,46.5,1.5067480648739633,9.360198219935995,7.485211794438884e-11,0.3399375637543141,16051.987958440164,6.627545668130812,-0.4199,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-275P,Risen Energy Co Ltd,Multi-c-Si,0,275.0,249.2,1.64,,,60.0,9.28,38.4,8.74,31.5,0.003712,-0.12222720000000001,46.7,1.5436526328031948,9.28634003542261,1.4439670286642737e-10,0.25968844368957184,380.1097000523438,6.399637367373939,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-280M,Risen Energy Co Ltd,Mono-c-Si,0,280.0,254.3,1.64,,,60.0,9.47,38.7,8.98,31.2,0.0031251000000000004,-0.1166031,46.5,1.5159474532529644,9.470797878843554,7.744821598199994e-11,0.33268158771746503,3948.590372733019,6.822236596244126,-0.4199,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-280P,Risen Energy Co Ltd,Multi-c-Si,0,280.0,253.8,1.64,,,60.0,9.36,38.6,8.82,31.8,0.0037440000000000004,-0.12286380000000001,46.7,1.5549514875004031,9.365827658343,1.5346189160413668e-10,0.24085410170309193,386.84398450778235,6.847627778702297,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-280M,Risen Energy Co Ltd,Mono-c-Si,0,280.0,253.0,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.95,35.2,0.00547281,-0.1629824,43.5,1.9421366146337358,8.330003780648534,7.991121891894052e-10,0.4532812278992699,999991.7952391377,7.387223391887183,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-280P,Risen Energy Co Ltd,Multi-c-Si,0,280.0,253.7,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.96,35.2,0.00536452,-0.16199679999999997,43.4,1.9234861955317217,8.330277352909736,6.387278121345622e-10,0.451918941768294,13573.087982724524,6.114890657788407,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd SYP280M,Risen Energy Co Ltd,Mono-c-Si,0,280.0,244.0,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.95,35.2,0.0040817,-0.19174399999999997,46.7,2.0427920967180597,8.468812814563195,2.5316788505062715e-09,0.4899560550097985,999999.9830915356,0.2090543431338401,-0.558,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd SYP280P,Risen Energy Co Ltd,Multi-c-Si,0,280.0,246.6,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.95,35.2,0.0039151,-0.17740799999999998,46.1,2.000041087519478,8.330003596320292,1.5582829120512742e-09,0.43079291923211044,999999.8467073918,4.30328235288091,-0.532,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-285M,Risen Energy Co Ltd,Mono-c-Si,0,285.0,259.0,1.64,,,60.0,9.56,38.8,9.08,31.4,0.0031548,-0.11690439999999999,46.5,1.522079421328952,9.564270607372313,8.125634700004843e-11,0.31490239120030056,999999.9272465825,7.146487261730492,-0.4199,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-285P,Risen Energy Co Ltd,Multi-c-Si,0,285.0,258.5,1.64,,,60.0,9.44,38.8,8.9,32.1,0.003776,-0.1235004,46.7,1.566241613334327,9.445329345874846,1.6293955550048055e-10,0.2223713582599523,393.8918297228541,7.289841989650599,-0.424,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-285M,Risen Energy Co Ltd,Mono-c-Si,0,285.0,257.6,1.9403519999999999,1.956,0.992,72.0,8.47,44.8,8.07,35.3,0.00556479,-0.1629824,43.5,1.943213383497843,8.470003749221203,8.229953247380218e-10,0.4420762970174945,999998.5548324574,7.498762278618682,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-285P,Risen Energy Co Ltd,Multi-c-Si,0,285.0,258.3,1.9403519999999999,1.956,0.992,72.0,8.48,44.8,8.07,35.32,0.00546112,-0.16199679999999997,43.4,1.9222047346528421,8.480003846773187,6.404405644834602e-10,0.45314663002747474,999999.4519740838,5.983447487310129,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM60-6-290M,Risen Energy Co Ltd,Mono-c-Si,0,290.0,263.7,1.64,,,60.0,9.65,38.9,9.18,31.6,0.0031845000000000003,-0.11720570000000001,46.5,1.5299871482483862,9.650002813799984,8.761262636817052e-11,0.2915372518464983,999999.9638762964,7.719286751403709,-0.4199,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-290M,Risen Energy Co Ltd,Mono-c-Si,0,290.0,262.3,1.9403519999999999,1.956,0.992,72.0,8.59,44.8,8.19,35.4,0.00564363,-0.1629824,43.5,1.9465480300253024,8.59000360216106,8.68279619884615e-10,0.4188022282482929,999998.2549567753,7.844192441484477,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-290P,Risen Energy Co Ltd,Multi-c-Si,0,290.0,263.0,1.9403519999999999,1.956,0.992,72.0,8.63,44.8,8.19,35.41,0.005557720000000001,-0.16199679999999997,43.4,1.9219806965177275,8.630003870965586,6.500008713398825e-10,0.44805961017476276,999999.9452640731,5.960103683421096,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd SYP290M,Risen Energy Co Ltd,Mono-c-Si,0,290.0,249.9,1.9403519999999999,1.956,0.992,72.0,8.63,44.8,8.19,35.4,0.0034520000000000006,-0.19891199999999998,47.6,2.0957282431511968,8.63000334991256,4.489261120419985e-09,0.38613961551612674,999999.9447590933,1.150116455815064,-0.582,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM120-6-295M,Risen Energy Co Ltd,Mono-c-Si,0,295.0,269.5,1.67,,,120.0,9.64,39.7,9.08,32.5,0.006371076000000001,-0.13718335,45.2,1.6433932772179953,9.645258718152126,3.0837901181463384e-10,0.255575860652346,468.508048776296,3.4978219767901986,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-295M,Risen Energy Co Ltd,Mono-c-Si,0,295.0,270.7,1.64,,,60.0,9.64,39.7,9.08,32.5,0.006103084000000002,-0.1266033,45.1,1.605791254893973,9.64626425295524,1.749335687478035e-10,0.2642727437123927,406.6868854605548,7.2348050315658465,-0.41043,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-295M,Risen Energy Co Ltd,Mono-c-Si,0,295.0,266.9,1.9403519999999999,1.956,0.992,72.0,8.64,44.8,8.28,35.6,0.00567648,-0.1629824,43.5,1.9575335634928086,8.640269724406169,9.93327331791495e-10,0.3578233796468469,11462.210046323404,8.979747749201994,-0.4902,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-295P,Risen Energy Co Ltd,Multi-c-Si,0,295.0,267.6,1.9403519999999999,1.956,0.992,72.0,8.7,44.8,8.29,35.6,0.0056028,-0.16199679999999997,43.4,1.930781180556847,8.700003468396881,7.287245007336675e-10,0.3982458446611746,999999.2936476545,6.877127396958642,-0.4808,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM120-6-300M,Risen Energy Co Ltd,Mono-c-Si,0,300.0,274.2,1.67,,,120.0,9.68,40.0,9.12,32.9,0.006397511999999999,-0.13822,45.2,1.66007634484285,9.684970993005942,3.294133912005223e-10,0.2365768946792945,460.68557910100986,4.017412633569248,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-300M,Risen Energy Co Ltd,Mono-c-Si,0,300.0,275.4,1.64,,,60.0,9.68,40.0,9.12,32.9,0.006128408,-0.12756,45.1,1.621965218221825,9.685916792534432,1.8677647735755774e-10,0.245383395062237,401.4525606081577,7.768391487742996,-0.41043,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-300M,Risen Energy Co Ltd,Mono-c-Si,0,300.0,270.7,1.9403519999999999,1.956,0.992,72.0,8.73,44.8,8.37,35.8,0.0047142,-0.14201599999999998,47.4,1.7914818257861356,8.730292297193389,1.203193517263283e-10,0.39109681425963744,11680.861959547283,5.597859174729604,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-300P,Risen Energy Co Ltd,Multi-c-Si,0,300.0,270.7,1.9403519999999999,1.956,0.992,72.0,8.95,44.5,8.4,35.8,0.004833,-0.141065,47.4,1.78406154122589,8.959399383028876,1.3002660812501273e-10,0.40699036442592484,387.5322549446417,6.083284850708349,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP300M,Risen Energy Co Ltd,Mono-c-Si,0,300.0,258.8,1.9403519999999999,1.956,0.992,72.0,8.93,44.8,8.37,35.8,0.003572,-0.19891199999999998,47.6,2.1003985325794816,8.932210662443158,4.8563395452205716e-09,0.37022990392029476,1495.5611492651153,1.5279467011866688,-0.582,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM120-6-305M,Risen Energy Co Ltd,Mono-c-Si,0,305.0,278.9,1.67,,,120.0,9.79,40.3,9.22,33.1,0.006470210999999999,-0.13925665,45.2,1.6715221485919762,9.795351749871605,3.282627606436599e-10,0.24157843597437476,441.9215017045704,3.893880992961037,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-305M,Risen Energy Co Ltd,Mono-c-Si,0,305.0,280.1,1.64,,,60.0,9.79,40.3,9.22,33.1,0.006198049,-0.12851669999999998,45.1,1.6331785848396874,9.796335693048524,1.8614583211944035e-10,0.2503340525548595,386.81965843508516,7.64161718858332,-0.41043,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-305M,Risen Energy Co Ltd,Mono-c-Si,0,305.0,275.3,1.9403519999999999,1.956,0.992,72.0,8.84,44.8,8.5,35.9,0.0047736,-0.14201599999999998,47.4,1.7961767846825456,8.840269181287791,1.3006576062793333e-10,0.35675283001019986,11715.904480680865,6.155772812762399,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-305P,Risen Energy Co Ltd,Multi-c-Si,0,305.0,278.6,1.94,,,72.0,9.0,44.8,8.45,36.1,0.0038699999999999997,-0.13681919999999997,45.9,1.7392921459006905,9.010824763618512,5.781708865337531e-11,0.41374595440365286,343.9995429067202,3.2725610782901193,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd SYP305M,Risen Energy Co Ltd,Mono-c-Si,0,305.0,263.3,1.9403519999999999,1.956,0.992,72.0,9.15,45.0,8.47,36.1,0.0036600000000000005,-0.1998,47.6,2.130597105367907,9.162640186226183,6.034380804674003e-09,0.3411601331427182,246.95998317548083,3.19193168272711,-0.582,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM120-6-310M,Risen Energy Co Ltd,Mono-c-Si,0,310.0,283.6,1.67,,,120.0,9.86,40.6,9.29,33.4,0.0065164739999999995,-0.1402933,45.2,1.6851259835602954,9.865026092416686,3.362627041419534e-10,0.23492591268018484,460.8689543826198,4.035454279384763,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-310M,Risen Energy Co Ltd,Mono-c-Si,0,310.0,284.8,1.64,,,60.0,9.86,40.6,9.29,33.4,0.006242366,-0.12947340000000002,45.1,1.6464353231456919,9.86598595237297,1.9065682442280737e-10,0.24370391846054124,401.42668442024524,7.786908169063384,-0.41043,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-310M,Risen Energy Co Ltd,Mono-c-Si,0,310.0,280.0,1.9403519999999999,1.956,0.992,72.0,8.91,44.9,8.61,36.0,0.0048113999999999995,-0.14233300000000002,47.4,1.8048266552662655,8.910242636374091,1.3977853621590473e-10,0.3207734719599127,11779.346643814939,6.706002997021613,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-310P,Risen Energy Co Ltd,Multi-c-Si,0,310.0,283.3,1.94,,,72.0,9.05,45.1,8.5,36.5,0.0038915,-0.1377354,45.9,1.754763850668562,9.060312349055431,6.149176306264233e-11,0.39247731421946436,344.4336313423401,3.740371370767334,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM120-6-315M,Risen Energy Co Ltd,Mono-c-Si,0,315.0,288.3,1.67,,,120.0,9.96,40.9,9.38,33.6,0.006582564,-0.14132995,45.2,1.6966275288912,9.96544531183886,3.349926135469322e-10,0.2400877329196399,439.14367735187943,3.9198583175210238,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-315M,Risen Energy Co Ltd,Mono-c-Si,0,315.0,289.6,1.64,,,60.0,9.96,40.9,9.38,33.6,0.006305676000000001,-0.1304301,45.1,1.6577015516079183,9.966443942033177,1.8995762367638162e-10,0.24882614375026396,384.59511199968705,7.6682993404296225,-0.41043,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-315M,Risen Energy Co Ltd,Mono-c-Si,0,315.0,284.6,1.9403519999999999,1.956,0.992,72.0,9.32,45.05,8.71,36.2,0.0050328000000000005,-0.14280849999999998,47.4,1.80886122064348,9.334049963164684,1.3994145813446212e-10,0.401370489825872,266.2479024297625,6.3807958118271815,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-315P,Risen Energy Co Ltd,Multi-c-Si,0,315.0,288.0,1.94,,,72.0,9.1,45.4,8.55,36.9,0.003913,-0.1386516,45.9,1.7702234255024791,9.109794734410249,6.53231028865967e-11,0.3714746636767334,345.126210421255,4.2005881977814745,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM120-6-320M,Risen Energy Co Ltd,Mono-c-Si,0,320.0,293.0,1.67,,,120.0,10.06,41.2,9.44,33.9,0.006648654,-0.1423666,45.2,1.7139711081711222,10.068001778732606,3.608739858172851e-10,0.23231753250955586,292.07439516205693,4.475740368072378,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM60-6-320M,Risen Energy Co Ltd,Mono-c-Si,0,320.0,294.3,1.64,,,60.0,10.06,41.2,9.44,33.9,0.006368986000000001,-0.13138680000000003,45.1,1.6745052036256125,10.069086143753289,2.0454000277681517e-10,0.24113808739821851,266.9833763345821,8.240061926635747,-0.41043,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-320M,Risen Energy Co Ltd,Mono-c-Si,0,320.0,289.3,1.9403519999999999,1.956,0.992,72.0,9.45,45.12,8.8,36.4,0.005103,-0.1430304,47.4,1.8190716060441219,9.467244377065656,1.562837997946271e-10,0.37723578305710864,206.72700010577742,7.227204274737744,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-320P,Risen Energy Co Ltd,Multi-c-Si,0,320.0,292.7,1.94,,,72.0,9.15,45.7,8.6,37.3,0.0039345000000000005,-0.13956780000000002,45.9,1.7856710954445636,9.159273594481306,6.931393834427663e-11,0.3507327732540753,346.05837062015524,4.653385713470327,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM120-6-325M,Risen Energy Co Ltd,Mono-c-Si,0,325.0,297.7,1.67,,,120.0,10.16,41.5,9.51,34.2,0.006714744,-0.14340325,45.2,1.7303656548879403,10.1696624330563,3.83616765984726e-10,0.22478323687336113,236.358474309765,4.918681824932211,-0.42612,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-325M,Risen Energy Co Ltd,Mono-c-Si,0,325.0,293.9,1.9403519999999999,1.956,0.992,72.0,9.58,45.18,8.91,36.5,0.005173199999999999,-0.1432206,47.4,1.8241288519764793,9.59842607331725,1.6395129533962807e-10,0.3657630286377835,190.16585550805075,7.528692924806432,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-325P,Risen Energy Co Ltd,Multi-c-Si,0,325.0,297.4,1.94,,,72.0,9.2,46.0,8.65,37.7,0.0039559999999999994,-0.140484,45.9,1.8011071144576074,9.208750428105573,7.34670637814641e-11,0.3302465556139836,347.21368832600234,5.098937157497385,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-330M,Risen Energy Co Ltd,Mono-c-Si,0,330.0,302.2,1.94,,,72.0,9.29,46.3,8.78,37.6,0.0034373,-0.13755729999999997,45.3,1.8062449719349647,9.294670599245666,6.806405891988684e-11,0.3737302791925496,743.3638393356005,7.3550022571641,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-330P,Risen Energy Co Ltd,Multi-c-Si,0,330.0,302.1,1.94,,,72.0,9.25,46.3,8.7,38.1,0.003977499999999999,-0.1414002,45.9,1.816531681912332,9.258226578075302,7.778515356650164e-11,0.3100110800130346,348.5778106154115,5.537404880994283,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-335M,Risen Energy Co Ltd,Mono-c-Si,0,335.0,306.9,1.94,,,72.0,9.32,46.7,8.83,37.9,0.0034484,-0.1387457,45.3,1.8190156074488348,9.322475281855606,6.580571369138169e-11,0.3790647257594732,1427.2652616000853,7.025850753186472,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-335P,Risen Energy Co Ltd,Multi-c-Si,0,335.0,306.8,1.94,,,72.0,9.3,46.5,8.75,38.4,0.003999,-0.142011,45.9,1.8275645459624776,9.307741959006098,8.176181319682704e-11,0.29170928540291224,350.4147255953215,5.915851787903562,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-340M,Risen Energy Co Ltd,Mono-c-Si,0,340.0,311.6,1.94,,,72.0,9.35,46.8,8.91,38.2,0.0034595,-0.13904279999999997,45.3,1.827605899253386,9.35000316320516,7.074780719587664e-11,0.3382754860907972,999999.9431435892,7.611585892156151,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-340P,Risen Energy Co Ltd,Multi-c-Si,0,340.0,311.5,1.94,,,72.0,9.35,46.8,8.8,38.6,0.0040205,-0.1429272,45.9,1.8378044258211992,9.357656169379117,8.049755870130325e-11,0.29837319550062025,364.384504089206,5.735614648279043,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-345M,Risen Energy Co Ltd,Mono-c-Si,0,345.0,316.3,1.94,,,72.0,9.38,46.9,8.97,38.5,0.0034706000000000003,-0.1393399,45.3,1.8390525296342313,9.380002764370861,7.883317182333708e-11,0.294679481064023,999999.3787819601,8.524060811364064,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-345P,Risen Energy Co Ltd,Multi-c-Si,0,345.0,316.2,1.94,,,72.0,9.4,47.1,8.85,39.0,0.004042,-0.1438434,45.9,1.8532082612576515,9.40715741565555,8.505801699686328e-11,0.278685114248736,366.00363829465977,6.160234426153151,-0.398,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-350M,Risen Energy Co Ltd,Mono-c-Si,0,350.0,321.0,1.94,,,72.0,9.41,47.0,9.03,38.8,0.0034817,-0.13963699999999998,45.3,1.850518287750624,9.41000235634732,8.775066060616885e-11,0.25037059900985204,999943.015589807,9.434999427842751,-0.408,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM72-6-355M,Risen Energy Co Ltd,Mono-c-Si,0,355.0,326.8,1.94,,,72.0,9.8,47.4,9.11,39.0,0.0049127400000000005,-0.14417658,45.1,1.8826383439343788,9.81710406052758,1.1092400902131152e-10,0.29613183124660925,169.67269325548165,8.4877312459939,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-360BMDG,Risen Energy Co Ltd,Mono-c-Si,0,360.0,328.7,2.01,,,72.0,9.7,47.3,9.1,39.6,0.0032688999999999995,-0.14979437,45.5,1.9131644482977097,9.707377835727282,1.745732628630673e-10,0.2063194773753794,271.2582784354908,8.304239618984125,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-360M,Risen Energy Co Ltd,Mono-c-Si,0,360.0,329.2,1.99,,,144.0,9.9,47.8,9.19,39.2,0.006073650000000001,-0.16293586,45.3,1.9793685240712464,9.916578599802756,3.136087829973307e-10,0.2926807535873529,174.7758964607318,4.9568351472699295,-0.42268,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-360M,Risen Energy Co Ltd,Mono-c-Si,0,360.0,331.5,1.94,,,72.0,9.9,47.8,9.19,39.2,0.00496287,-0.14539326,45.1,1.8964703320247265,9.919175659248154,1.0889500803412701e-10,0.3118440022292796,160.9986730509823,8.241886632970607,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-365BMDG,Risen Energy Co Ltd,Mono-c-Si,0,365.0,333.4,2.01,,,72.0,9.8,47.45,9.2,39.7,0.0033026,-0.15026940500000002,45.5,1.9178514039504952,9.807209510905578,1.7341218042974984e-10,0.20825562385922777,283.0851068752866,8.153997826747007,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-365M,Risen Energy Co Ltd,Mono-c-Si,0,365.0,333.9,1.99,,,144.0,10.0,48.0,9.25,39.5,0.006135000000000001,-0.1636176,45.3,1.9955669849174107,10.01835937398188,3.4702120747877755e-10,0.27309326237693476,148.74868705368095,5.746660317127859,-0.42268,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-365M,Risen Energy Co Ltd,Mono-c-Si,0,365.0,336.2,1.94,,,72.0,10.0,48.0,9.25,39.5,0.005013,-0.14600159999999998,45.1,1.9116449784333203,10.021084033470748,1.2045817147183062e-10,0.2924326575530166,138.69863370470972,9.05259300906237,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-370BMDG,Risen Energy Co Ltd,Mono-c-Si,0,370.0,338.1,2.01,,,72.0,9.9,47.6,9.3,39.8,0.0033363000000000004,-0.15074444000000004,45.5,1.92255157953637,9.907029783382491,1.72282215933392e-10,0.21014469212759168,295.9454706055567,8.006107610604209,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-370M,Risen Energy Co Ltd,Mono-c-Si,0,370.0,342.3,2.01,,,72.0,9.9,47.7,9.3,39.85,0.0039592080000000005,-0.12059037,45.6,1.7994991603952282,9.909871615077417,2.988462621258589e-11,0.24440980415710853,245.11258422376875,17.58370807711011,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-370M,Risen Energy Co Ltd,Mono-c-Si,0,370.0,341.0,1.94,,,72.0,10.05,48.4,9.3,39.8,0.005038065,-0.14721828,45.1,1.9263741723296852,10.071118978651114,1.1924632474610957e-10,0.29712290562138666,141.3934505740733,8.918112003204902,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-375BMDG,Risen Energy Co Ltd,Mono-c-Si,0,375.0,342.8,2.01,,,72.0,10.0,47.75,9.4,39.9,0.00337,-0.15121947500000002,45.5,1.9272645286312893,10.00683875455812,1.7118206558652014e-10,0.2119883755033589,309.98098313417313,7.860497502655385,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-375M,Risen Energy Co Ltd,Mono-c-Si,0,375.0,347.1,2.01,,,72.0,10.0,47.85,9.4,39.95,0.0039992000000000005,-0.120969585,45.6,1.804006765974039,10.009672654216944,2.9704565114962495e-11,0.24591918844944535,254.24168499191268,17.427589428386838,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-375M,Risen Energy Co Ltd,Mono-c-Si,0,375.0,345.7,1.94,,,72.0,10.1,48.8,9.36,40.1,0.00506313,-0.14843496,45.1,1.940005169776593,10.120322303073998,1.1655099679592203e-10,0.30189836205289133,150.04074648037258,8.668203930496535,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-380BMDG,Risen Energy Co Ltd,Mono-c-Si,0,380.0,347.6,2.01,,,72.0,10.1,48.0,9.5,40.05,0.0034037,-0.1520112,45.5,1.9351276215157371,10.106729439598313,1.681839443911173e-10,0.21834301025448105,327.7040351883354,7.618275161898726,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-380M,Risen Energy Co Ltd,Mono-c-Si,0,380.0,351.8,2.01,,,72.0,10.1,48.0,9.5,40.05,0.004039192,-0.12134879999999998,45.6,1.8085247804620217,10.10946308334128,2.9529166447787856e-11,0.2473923855399902,264.04323272804675,17.273824097258956,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-380M,Risen Energy Co Ltd,Mono-c-Si,0,380.0,350.5,1.94,,,72.0,10.15,49.2,9.41,40.4,0.005088195,-0.14965164,45.1,1.954729901984436,10.170324698277737,1.1542956289393952e-10,0.30648511054610067,153.05634054815394,8.53856184742904,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-385BMDG,Risen Energy Co Ltd,Mono-c-Si,0,385.0,352.3,2.01,,,72.0,10.2,48.15,9.6,40.15,0.0034373999999999997,-0.152486235,45.5,1.939864503154004,10.206508326361108,1.6716007196659755e-10,0.22005357881715376,344.87309103538394,7.477600787344473,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-385M,Risen Energy Co Ltd,Mono-c-Si,0,385.0,356.6,2.01,,,72.0,10.2,48.15,9.6,40.15,0.004079184,-0.12172801499999998,45.6,1.813052836422857,10.209242990915994,2.935823072969114e-11,0.24883068217456822,274.5943368667544,17.122341741805243,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-385M,Risen Energy Co Ltd,Mono-c-Si,0,385.0,355.2,1.94,,,72.0,10.2,49.6,9.44,40.8,0.00511326,-0.15086832,45.1,1.9743596537742993,10.221235643668003,1.213859607786665e-10,0.298391701001192,143.3248486213817,8.943829615489026,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-390BMDG,Risen Energy Co Ltd,Mono-c-Si,0,390.0,357.0,2.01,,,72.0,10.3,48.3,9.7,40.25,0.0034711000000000004,-0.15296127,45.5,1.9446129353887702,10.306276239034506,1.6616203306460818e-10,0.2217243465047905,363.87411181271426,7.339009045759256,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-390M,Risen Energy Co Ltd,Mono-c-Si,0,390.0,361.3,2.01,,,72.0,10.3,48.3,9.7,40.25,0.0041191760000000004,-0.12210722999999998,45.6,1.8175906126253656,10.309012462610974,2.9191582320503006e-11,0.25023529862224786,285.9843877438811,16.973078786800112,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM72-6-390M,Risen Energy Co Ltd,Mono-c-Si,0,390.0,360.0,1.94,,,72.0,10.25,50.0,9.49,41.1,0.005138325000000001,-0.152085,45.1,1.9890836108944638,10.271258950443958,1.2021396609498124e-10,0.3029588399119789,146.07156563948075,8.813978477832489,-0.39769,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-395BMDG,Risen Energy Co Ltd,Mono-c-Si,0,395.0,361.7,2.01,,,72.0,10.4,48.45,9.8,40.35,0.0035048,-0.15343630500000002,45.5,1.9493725434586429,10.406033268402886,1.65188802158924e-10,0.22335668328002767,385.0167930133741,7.202441569122472,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-395M,Risen Energy Co Ltd,Mono-c-Si,0,395.0,366.1,2.01,,,72.0,10.4,48.45,9.8,40.35,0.004159168,-0.122486445,45.6,1.8221377940431356,10.408771582210733,2.9029051669026985e-11,0.2516074008484947,298.31755932969855,16.825973432929487,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-400BMDG,Risen Energy Co Ltd,Mono-c-Si,0,400.0,366.4,2.01,,,72.0,10.5,48.6,9.9,40.45,0.0035385,-0.15391134000000004,45.5,1.9541429685961602,10.505779503062207,1.6423940788398977e-10,0.22495189728688839,408.68480449864285,7.067842367555814,-0.42309,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-400M,Risen Energy Co Ltd,Mono-c-Si,0,400.0,370.9,2.01,,,72.0,10.5,48.6,9.9,40.45,0.0041991599999999995,-0.12286566,45.6,1.8266940792851325,10.508520431542772,2.88704782206001e-11,0.2529481020761567,311.7160308061349,16.680966160571888,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-405BMDG,Risen Energy Co Ltd,Mono-c-Si,1,405.0,374.6,2.0,,,144.0,10.6,48.75,10.0,40.55,0.00510125,-0.148507125,45.8,1.8831452710875165,10.607085479378116,5.987588703219836e-11,0.24289548836768074,363.3758709783593,2.4001108454153557,-0.37511,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-405M,Risen Energy Co Ltd,Mono-c-Si,0,405.0,375.6,2.01,,,72.0,10.6,48.75,10.0,40.55,0.0042391519999999995,-0.12324487499999999,45.6,1.8312591706993566,10.60825908997134,2.8715704510564674e-11,0.25425846117079465,326.3238638748072,16.538008547199635,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-410BMDG,Risen Energy Co Ltd,Mono-c-Si,1,410.0,379.4,2.0,,,144.0,10.7,48.9,10.1,40.65,0.005149375,-0.14896407,45.8,1.8877840707964186,10.706812678611533,5.953352891799427e-11,0.2442813289004227,383.6685152259102,2.27288279494053,-0.37511,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-410M,Risen Energy Co Ltd,Mono-c-Si,0,410.0,380.4,2.01,,,72.0,10.7,48.9,10.1,40.65,0.0042791439999999995,-0.12362408999999999,45.6,1.835832815160804,10.707987636799185,2.8564600762803564e-11,0.2555395070209595,342.3131054751172,16.39702111842126,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-415BMDG,Risen Energy Co Ltd,Mono-c-Si,1,415.0,384.2,2.0,,,144.0,10.8,49.0,10.2,40.7,0.005197500000000001,-0.1492687,45.8,1.8902923813571884,10.806543950861839,5.902976663939748e-11,0.24634672828994933,406.56551269741556,2.1237294317597644,-0.37511,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-6-415M,Risen Energy Co Ltd,Mono-c-Si,0,415.0,385.2,2.01,,,72.0,10.8,49.0,10.2,40.7,0.004319136,-0.12387689999999998,45.6,1.8354247842185425,10.807792170783616,2.7159238300086013e-11,0.2581153749667362,357.7496132602492,15.83368819696233,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-425BMDG,Risen Energy Co Ltd,Mono-c-Si,1,425.0,396.4,2.23,,,72.0,11.0,49.2,10.4,40.9,0.0041950699999999995,-0.13140336,45.3,1.787711783298074,11.00836981028058,1.2126867341636078e-11,0.2625171765877001,345.0124523578374,2.551726525479769,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-425M,Risen Energy Co Ltd,Mono-c-Si,0,425.0,395.5,2.21,,,72.0,11.0,49.2,10.4,40.9,0.0060627599999999995,-0.10363980000000002,45.4,1.8114382058001814,11.007791919206827,1.7400724195690713e-11,0.25745132838908386,363.4488842743609,33.87746947685752,-0.34803,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-430BMDG,Risen Energy Co Ltd,Mono-c-Si,1,430.0,401.2,2.23,,,72.0,11.1,49.3,10.5,40.96,0.004233207,-0.13167044,45.3,1.7903984961558888,11.108076016585416,1.2068295378345265e-11,0.2632449243315478,361.8143483411521,2.433576781667226,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-430M,Risen Energy Co Ltd,Mono-c-Si,0,430.0,400.2,2.21,,,72.0,11.1,49.3,10.5,40.96,0.0061178759999999995,-0.10385045,45.4,1.8142226175124048,11.107495018990997,1.7336138060409655e-11,0.2582093684588561,382.4038362781886,33.735188008499954,-0.34803,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-435BMDG,Risen Energy Co Ltd,Mono-c-Si,1,435.0,406.0,2.23,,,72.0,11.2,49.4,10.6,41.05,0.004271343999999999,-0.13193752,45.3,1.7790213533103267,11.200007858566394,9.765423513927733e-12,0.26354442813330337,375604.53820140584,0.5686725091972371,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-435M,Risen Energy Co Ltd,Mono-c-Si,0,435.0,405.0,2.21,,,72.0,11.2,49.4,10.6,41.05,0.0061729919999999995,-0.1040611,45.4,1.817633580385094,11.207142864886901,1.7432264675659587e-11,0.2557094832889727,400.9520388208083,33.694927239895314,-0.34803,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-440BMDG,Risen Energy Co Ltd,Mono-c-Si,1,440.0,410.8,2.23,,,72.0,11.3,49.5,10.7,41.13,0.0043094809999999996,-0.13220459999999998,45.3,1.7968852652300382,11.307383465930867,1.2154694985267928e-11,0.2592925322050929,396.8333654077686,2.3400059290943287,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-440M,Risen Energy Co Ltd,Mono-c-Si,0,440.0,409.8,2.21,,,72.0,11.3,49.5,10.7,41.13,0.0062281079999999996,-0.10427175,45.4,1.8208443696949612,11.306806911459324,1.7475723051686888e-11,0.2543239118519114,422.19738654828444,33.622488180308636,-0.34803,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-445BMDG,Risen Energy Co Ltd,Mono-c-Si,1,445.0,415.6,2.23,,,72.0,11.4,49.6,10.8,41.25,0.004347618,-0.13247168,45.3,1.8009003930407634,11.406986891397041,1.2340747650468199e-11,0.25365228991567196,413.86590416971444,2.391279331262121,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-445M,Risen Energy Co Ltd,Mono-c-Si,0,445.0,414.6,2.21,,,72.0,11.4,49.6,10.8,41.25,0.0062832240000000004,-0.10448240000000002,45.4,1.6767663565668487,11.410216770771745,1.6011965521875727e-12,0.2795714092314226,311.9492586537086,9.682078556112877,-0.34803,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-450BMDG,Risen Energy Co Ltd,Mono-c-Si,1,450.0,420.4,2.23,,,72.0,11.5,49.7,10.9,41.3,0.004385755,-0.13273876,45.3,1.8033980156871663,11.506693178532808,1.2243263992605601e-11,0.25547536259759857,438.94939862258934,2.250316075529329,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-450M,Risen Energy Co Ltd,Mono-c-Si,0,450.0,419.4,2.21,,,72.0,11.5,49.7,10.9,41.3,0.0063383400000000005,-0.10469305000000001,45.4,1.698178910980997,11.500009901345857,2.2405249328403715e-12,0.2769249831664132,321637.21305156196,12.659538280731153,-0.34803,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM144-7-455BMDG,Risen Energy Co Ltd,Mono-c-Si,1,455.0,425.2,2.23,,,72.0,11.6,49.8,11.0,41.4,0.004423892,-0.13300584,45.3,1.795170176517544,11.600009915995127,1.0390688440183294e-11,0.25424095187122137,297419.259546445,0.7897065965819902,-0.33712,N,2025.7.3,6/23/2025,4.0,first_pass +Risen Energy Co Ltd RSM110-8-525BMDG,Risen Energy Co Ltd,Mono-c-Si,1,525.0,491.6,2.61,,,11.0,17.97,37.22,16.97,30.96,0.0032119578000000004,-0.127039304,45.2,1.3109690391291289,17.98748110571847,8.276032269572557e-12,0.12586927192716416,129.38945956276365,-25.0738576145116,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-525M,Risen Energy Co Ltd,Mono-c-Si,0,525.0,492.2,2.6,,,55.0,18.03,37.18,17.02,30.86,0.0032645118000000006,-0.092474096,45.0,1.2975239977095974,18.04917841761344,6.377058816653282e-12,0.1312267777693794,123.3688229646166,0.6989245414147776,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-530BMDG,Risen Energy Co Ltd,Mono-c-Si,1,530.0,496.4,2.61,,,11.0,18.02,37.44,17.02,31.16,0.0032208948,-0.12779020800000002,45.2,1.3189716350576597,18.03720206591321,8.345679333298833e-12,0.12512500604212218,131.07452473462365,-25.040000904620925,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-530M,Risen Energy Co Ltd,Mono-c-Si,0,530.0,497.0,2.6,,,55.0,18.08,37.38,17.07,31.06,0.0032735648,-0.09297153600000001,45.0,1.3050853510638927,18.098771959912145,6.477511996487406e-12,0.12929989024992505,124.53372066461417,0.8045434556712212,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-535BMDG,Risen Energy Co Ltd,Mono-c-Si,1,535.0,501.2,2.61,,,11.0,18.07,37.66,17.07,31.36,0.0032298318,-0.128541112,45.2,1.3269734177642627,18.0869269118383,8.415144401849227e-12,0.12438537145454791,132.7852173282916,-25.006691011178738,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-535M,Risen Energy Co Ltd,Mono-c-Si,0,535.0,501.8,2.6,,,55.0,18.13,37.58,17.12,31.26,0.0032826178,-0.093468976,45.0,1.3126456699622489,18.148371070963314,6.578386651122485e-12,0.1273847691228591,125.7131863724369,0.9089727876087084,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-540BHDG,Risen Energy Co Ltd,Mono-c-Si,1,540.0,511.7,3.11,,,110.0,16.93,40.73,15.83,34.15,0.00741534,-0.0944936,43.6,1.3917522341133222,16.95873573498846,3.208241868540615e-12,0.13433937037047858,79.14763768294397,2.2533930676690574,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-540BMDG,Risen Energy Co Ltd,Mono-c-Si,1,540.0,506.0,2.61,,,11.0,18.13,37.88,17.12,31.56,0.0032405562,-0.129292016,45.2,1.335323328381103,18.14738618405896,8.546774765541282e-12,0.12356544001622856,128.85181848840904,-24.930515211664922,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-540M,Risen Energy Co Ltd,Mono-c-Si,0,540.0,506.6,2.6,,,55.0,18.18,37.78,17.17,31.46,0.0032916708,-0.09396641600000001,45.0,1.3202050584698055,18.197975705668163,6.67968227533136e-12,0.1254813838032754,126.90748297265512,1.0119743301377178,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-545BHDG,Risen Energy Co Ltd,Mono-c-Si,1,545.0,516.5,3.11,,,110.0,17.04,40.82,15.95,34.23,0.0074635199999999995,-0.0947024,43.6,1.3942313708871719,17.067640711208238,3.192905095138011e-12,0.13348657114911613,82.29206279605881,2.1529651373041587,-0.2786,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM110-8-545BMDG,Risen Energy Co Ltd,Mono-c-Si,1,545.0,510.8,2.61,,,11.0,18.18,38.1,17.17,31.76,0.0032494932,-0.13004292,45.2,1.3433247822939576,18.197111569477972,8.616225084962984e-12,0.12283487623957773,130.50457224300732,-24.898238519797427,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-545M,Risen Energy Co Ltd,Mono-c-Si,0,545.0,511.4,2.6,,,55.0,18.23,38.02,17.22,31.66,0.0033007238000000005,-0.09456334400000001,45.0,1.3284967670414045,18.2478073121298,6.685622596334069e-12,0.1259261172273851,128.9151955510198,0.9959869840300578,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-550BHDG,Risen Energy Co Ltd,Mono-c-Si,1,550.0,521.3,3.11,,,110.0,17.15,40.91,16.06,34.3,0.007511699999999999,-0.0949112,43.6,1.396922370009674,17.17738896281737,3.1895019979202862e-12,0.13332687932149792,83.48457722595431,2.0873177890400165,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-550BMDG,Risen Energy Co Ltd,Mono-c-Si,1,550.0,515.6,2.61,,,11.0,18.23,38.32,17.22,31.96,0.0032584302000000006,-0.130793824,45.2,1.3513254252744902,18.246840753223424,8.68548801473306e-12,0.12210882424526992,132.18196603773455,-24.866432874470213,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-550M,Risen Energy Co Ltd,Mono-c-Si,0,550.0,516.2,2.6,,,55.0,18.28,38.24,17.27,31.86,0.0033097768000000002,-0.095110528,45.0,1.3364211455892734,18.297531194078246,6.739022356912261e-12,0.12520352856180303,130.5513187459824,1.038534609594491,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-555BHDG,Risen Energy Co Ltd,Mono-c-Si,1,555.0,526.2,3.11,,,110.0,17.25,41.0,16.17,34.38,0.007555500000000001,-0.09512000000000001,43.6,1.3994391990196886,17.27632539922041,3.174682325304225e-12,0.1325654351626089,86.86492211100034,1.9940503561938372,-0.2786,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM110-8-555BMDG,Risen Energy Co Ltd,Mono-c-Si,1,555.0,520.4,2.61,,,11.0,18.28,38.54,17.27,32.16,0.0032673672000000007,-0.131544728,45.2,1.35932526537631,18.296573674562218,8.75456402934089e-12,0.12138724163886089,133.88453924070055,-24.83508923444071,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-555M,Risen Energy Co Ltd,Mono-c-Si,0,555.0,521.0,2.6,,,55.0,18.33,38.46,17.32,32.06,0.0033188298,-0.09565771199999999,45.0,1.3443447506728223,18.347258835833685,6.7922767281674466e-12,0.12448537447456282,132.2115199557498,1.0804643171765715,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-560BHDG,Risen Energy Co Ltd,Mono-c-Si,1,560.0,531.0,3.11,,,110.0,17.36,41.09,16.28,34.45,0.00760368,-0.09532880000000002,43.6,1.4021382797291841,17.386068513525178,3.1717424769194635e-12,0.13241199616050914,88.17811004828194,1.930334221488445,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-560BMDG,Risen Energy Co Ltd,Mono-c-Si,1,560.0,525.2,2.61,,,11.0,18.33,38.76,17.32,32.35,0.0032763042,-0.132295632,45.2,1.3671153856858298,18.346373642966146,8.785561443957518e-12,0.12132939601416508,135.82608576737195,-24.830663988956854,-0.327,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-560M,Risen Energy Co Ltd,Mono-c-Si,0,560.0,525.8,2.6,,,55.0,18.38,38.68,17.37,32.26,0.0033278827999999997,-0.09620489600000001,45.0,1.352267591245769,18.396990177825128,6.845386288251027e-12,0.12377161400649114,133.89631898759293,1.1217858097973086,-0.325,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-565BHDG,Risen Energy Co Ltd,Mono-c-Si,1,565.0,535.8,3.11,,,110.0,17.47,41.18,16.39,34.53,0.00765186,-0.0955376,43.6,1.4050304521759818,17.495691251363386,3.181463258370144e-12,0.13156721849090472,89.4654478180185,1.9009221219066552,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-565BMDG,Risen Energy Co Ltd,Mono-c-Si,1,565.0,529.6,2.83,,,10.0,17.9,40.22,16.9,33.45,0.007660304999999999,-0.08767557799999999,45.1,1.4308027922283402,17.916994493886968,1.0921875858908843e-11,0.13502653874942644,142.22106685302273,19.826804755666203,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-570BHDG,Risen Energy Co Ltd,Mono-c-Si,1,570.0,540.6,3.11,,,110.0,17.57,41.27,16.49,34.6,0.007695659999999999,-0.09574640000000002,43.6,1.4077583306973864,17.59546059411903,3.1783518239102702e-12,0.1314944989232177,90.74251513921273,1.8425788616624157,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-570BMDG,Risen Energy Co Ltd,Mono-c-Si,1,570.0,534.4,2.83,,,10.0,17.95,40.44,16.95,33.64,0.0076817025,-0.088155156,45.1,1.4386640762613319,17.966784067973133,1.0961756095963023e-11,0.1349178765431471,144.2901622395401,19.834421269074113,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-575BHDG,Risen Energy Co Ltd,Mono-c-Si,1,575.0,545.5,3.11,,,110.0,17.67,41.36,16.6,34.68,0.007739460000000001,-0.0959552,43.6,1.410295052101597,17.694400670179206,3.164762407409439e-12,0.13075967164227595,94.6909811163843,1.7540449703097787,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-575BMDG,Risen Energy Co Ltd,Mono-c-Si,1,575.0,539.2,2.83,,,10.0,18.0,40.68,17.0,33.84,0.0077031,-0.088678332,45.1,1.4471030576355268,18.01661257929039,1.0973248636718179e-11,0.13532211942133324,146.62371894017573,19.816566204715464,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-575M,Risen Energy Co Ltd,Mono-c-Si,0,575.0,539.2,2.8,,,60.0,18.06,40.6,17.05,33.74,0.007084396199999999,-0.08872724000000001,45.1,1.4410715891011787,18.07753003483762,1.0341814981113055e-11,0.1372005176755288,141.34834179563984,18.952980527370453,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-580BHDG,Risen Energy Co Ltd,Mono-c-Si,1,580.0,550.3,3.11,,,110.0,17.77,41.46,16.71,34.76,0.007783259999999999,-0.09618720000000001,43.6,1.4130197781939333,17.79343207138704,3.1412923897391743e-12,0.13063379920650317,99.06775098343434,1.6390500259947258,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-580BMDG,Risen Energy Co Ltd,Mono-c-Si,1,580.0,544.0,2.83,,,10.0,18.06,40.9,17.05,34.04,0.007728776999999999,-0.08915790999999999,45.1,1.4555250802295159,18.077085276563995,1.1131665917915393e-11,0.13445390766256143,142.12456966078926,19.92679108304977,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-580M,Risen Energy Co Ltd,Mono-c-Si,0,580.0,544.0,2.8,,,60.0,18.11,40.8,17.1,33.94,0.0071040097,-0.08916432,45.1,1.4487423206239736,18.12716183080244,1.0487435375247914e-11,0.13524435730746875,142.71643542420435,19.061778574098433,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-585BHDG,Risen Energy Co Ltd,Mono-c-Si,1,585.0,555.1,3.11,,,110.0,17.88,41.55,16.81,34.84,0.007831439999999999,-0.096396,43.6,1.4163037149223838,17.903775609503548,3.174158355986914e-12,0.12979803955218883,97.61217470135189,1.675818887352021,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-585BMDG,Risen Energy Co Ltd,Mono-c-Si,1,585.0,548.8,2.83,,,10.0,18.11,41.1,17.1,34.22,0.0077501745,-0.08959389000000001,45.1,1.4628070757607248,18.12683882319691,1.1199541502455416e-11,0.13383908469701175,143.94270920020415,19.958634453537464,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-585M,Risen Energy Co Ltd,Mono-c-Si,0,585.0,548.8,2.8,,,60.0,18.16,41.0,17.15,34.12,0.0071236232,-0.08960140000000001,45.1,1.456010979545641,18.176914243123253,1.0552020749883054e-11,0.13463075809254452,144.54649586132217,19.094052524672893,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-590BHDG,Risen Energy Co Ltd,Mono-c-Si,1,590.0,559.9,3.11,,,110.0,17.98,41.64,16.92,34.92,0.00787524,-0.0966048,43.6,1.4188543192901255,18.00272261788426,3.1614071914188327e-12,0.12908458204211395,102.14231470275972,1.5904707640184899,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-590BMDG,Risen Energy Co Ltd,Mono-c-Si,1,590.0,553.6,2.83,,,10.0,18.16,41.3,17.15,34.42,0.007771572,-0.09002986999999998,45.1,1.4704894893073421,18.17647969632607,1.135328750580731e-11,0.1318973901793648,145.3459193110663,20.065014212635013,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-590M,Risen Energy Co Ltd,Mono-c-Si,0,590.0,553.6,2.8,,,60.0,18.21,41.2,17.2,34.32,0.0071432367000000005,-0.09003848000000002,45.1,1.4636798201134444,18.226555710472315,1.0698029692636549e-11,0.13269427059213204,145.95342665281464,19.200766922429846,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-595BHDG,Risen Energy Co Ltd,Mono-c-Si,1,595.0,564.8,3.11,,,110.0,18.08,41.73,17.03,34.99,0.007919039999999999,-0.0968136,43.6,1.4212216632791874,18.101767228634525,3.1368700092733887e-12,0.12904501290884976,107.18561714729381,1.4736083078375617,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-595BMDG,Risen Energy Co Ltd,Mono-c-Si,1,595.0,558.4,2.83,,,10.0,18.21,41.5,17.2,34.6,0.0077929695,-0.09046585,45.1,1.47777009524314,18.22624064740728,1.142087804717919e-11,0.13129406557491313,147.21487889570108,20.095636159014717,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-595M,Risen Energy Co Ltd,Mono-c-Si,0,595.0,558.4,2.8,,,60.0,18.26,41.4,17.25,34.5,0.0071628502,-0.09047556,45.1,1.4709471021464626,18.276315525285394,1.0762351063146553e-11,0.13209211270836463,147.83477347325325,19.231804149597195,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM110-8-600BHDG,Risen Energy Co Ltd,Mono-c-Si,1,600.0,569.6,3.11,,,110.0,18.18,41.82,17.13,35.07,0.007962839999999999,-0.09702240000000001,43.6,1.4241562574103928,18.20143136377301,3.1469475040353746e-12,0.12832290683100353,108.85496939553596,1.4526428072926787,-0.2786,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-600BMDG,Risen Energy Co Ltd,Mono-c-Si,1,600.0,563.2,2.83,,,10.0,18.26,41.7,17.25,34.8,0.007814367000000001,-0.09090183,45.1,1.485450633091372,18.275891022152788,1.1574991666119614e-11,0.1293718128300958,148.65810935806124,20.199994266208318,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-600M,Risen Energy Co Ltd,Mono-c-Si,0,600.0,563.2,2.8,,,60.0,18.32,41.6,17.3,34.7,0.0071863864,-0.09091264000000002,45.1,1.4789778071420585,18.336673917021148,1.0983443467186211e-11,0.1300853487903508,142.92763921627244,19.400697464821103,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-605BMDG,Risen Energy Co Ltd,Mono-c-Si,1,605.0,568.0,2.83,,,10.0,18.32,41.9,17.3,34.98,0.007840044000000001,-0.09133780999999999,45.1,1.493096708900122,18.336353217313714,1.1721762741449855e-11,0.12868928265508614,144.16659545537246,20.293870540023526,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-605M,Risen Energy Co Ltd,Mono-c-Si,0,605.0,568.1,2.8,,,60.0,18.37,41.8,17.35,34.88,0.0072059999,-0.09134972,45.1,1.486244593227678,18.386435892475333,1.1047733845600592e-11,0.12949443354665194,144.7328007493662,19.43039405005357,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-610BMDG,Risen Energy Co Ltd,Mono-c-Si,1,610.0,572.8,2.83,,,10.0,18.37,42.2,17.35,35.18,0.0078614415,-0.09199178000000001,45.1,1.5026677059262212,18.386487795975743,1.1514299391871953e-11,0.13258132753306176,147.71646842619046,20.090021210939206,-0.323,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM120-8-610M,Risen Energy Co Ltd,Mono-c-Si,0,610.0,572.9,2.8,,,60.0,18.42,42.0,17.4,35.08,0.007225613400000001,-0.0917868,45.1,1.4939110182032633,18.436083414397615,1.1195303721358762e-11,0.12759620361621415,146.1332785901606,19.533048180114825,-0.324,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-635BMDG,Risen Energy Co Ltd,Mono-c-Si,1,635.0,595.6,2.91,,,22.0,18.03,44.89,17.02,37.33,0.009812827500000001,-0.12334874200000001,43.4,1.70821557304247,18.042377145656136,6.886607497729077e-11,0.13538343595833163,197.2153714521711,9.988971213745549,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-635M,Risen Energy Co Ltd,Mono-c-Si,0,635.0,595.7,2.91,,,22.0,18.08,44.75,17.07,37.22,0.0098235872,-0.1229193,43.1,1.711963813336899,18.09181809569299,7.941434112788399e-11,0.1330026900048308,203.47514451225535,11.279106594175172,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-640BMDG,Risen Energy Co Ltd,Mono-c-Si,1,640.0,600.4,2.91,,,22.0,18.08,45.09,17.07,37.51,0.00984004,-0.12389830200000002,43.4,1.7160122116949406,18.092162546471037,6.926488924069446e-11,0.13469573251411854,200.22935929769787,10.015156504374291,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-640M,Risen Energy Co Ltd,Mono-c-Si,0,640.0,600.6,2.91,,,22.0,18.13,44.95,17.12,37.4,0.009850754199999999,-0.12346866,43.1,1.71980278108307,18.141607501154105,7.987397828578584e-11,0.13231824090982766,206.67064564014782,11.305627306660163,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-645BMDG,Risen Energy Co Ltd,Mono-c-Si,1,645.0,605.3,2.91,,,22.0,18.13,45.29,17.12,37.69,0.0098672525,-0.12444786200000002,43.4,1.7238082192314126,18.141950469294237,6.966296451068152e-11,0.13401223785466845,203.3093308975489,10.041028236697425,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-645M,Risen Energy Co Ltd,Mono-c-Si,0,645.0,605.4,2.91,,,22.0,18.18,45.15,17.17,37.58,0.009877921199999999,-0.12401801999999999,43.1,1.7276411059811763,18.191399407959256,8.033274545000177e-11,0.1316379712081279,209.93882977439634,11.331829026460438,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-650BHDG,Risen Energy Co Ltd,Mono-c-Si,1,650.0,619.0,3.11,,,11.0,16.97,48.93,15.86,41.03,0.002126341,-0.10942705200000001,43.9,1.5756939779569725,17.004521831417325,5.365827141790355e-13,0.17485066551715933,85.95186500165396,-8.220829476924543,-0.26623,N,2025.7.3,6/23/2025,2.0,first_pass +Risen Energy Co Ltd RSM132-8-650BMDG,Risen Energy Co Ltd,Mono-c-Si,1,650.0,610.1,2.91,,,22.0,18.18,45.49,17.17,37.87,0.009894465,-0.12499742200000002,43.4,1.7316036037723344,18.19174087999843,7.006030663330383e-11,0.13333291364582678,206.4574729146549,10.06658959699794,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-650M,Risen Energy Co Ltd,Mono-c-Si,0,650.0,610.2,2.91,,,22.0,18.23,45.35,17.22,37.76,0.0099050882,-0.12456737999999999,43.1,1.7354788057456445,18.241193781621817,8.079065996880107e-11,0.1309618432326668,213.28220736744981,11.357713005630975,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-655BHDG,Risen Energy Co Ltd,Mono-c-Si,1,655.0,623.8,3.11,,,11.0,17.06,49.02,15.96,41.1,0.002137618,-0.10962832800000001,43.9,1.5778313693846093,17.09353924256502,5.320322151884731e-13,0.174651694310569,88.83796047135056,-8.333638737001726,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-655BMDG,Risen Energy Co Ltd,Mono-c-Si,1,655.0,614.9,2.91,,,22.0,18.23,45.69,17.22,38.05,0.009921677500000002,-0.125546982,43.4,1.7393983781154927,18.24153374486754,7.045692551106153e-11,0.13265772312468743,209.67607354592727,10.091840013616743,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-655M,Risen Energy Co Ltd,Mono-c-Si,0,655.0,615.0,2.91,,,22.0,18.28,45.55,17.27,37.94,0.009932255200000002,-0.12511673999999998,43.1,1.7433158740860915,18.290990589135383,8.124771540359116e-11,0.1302898158207387,216.70338644089804,11.38329326078592,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-660BHDG,Risen Energy Co Ltd,Mono-c-Si,1,660.0,628.7,3.11,,,11.0,17.14,49.11,16.05,41.18,0.002147642,-0.109829604,43.9,1.5801686972101654,17.17246417031334,5.292554070235474e-13,0.17385247701568365,91.78831388745262,-8.415155039962361,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-660BMDG,Risen Energy Co Ltd,Mono-c-Si,1,660.0,619.7,2.91,,,22.0,18.28,45.89,17.27,38.23,0.009948890000000002,-0.126096542,43.4,1.7471925325836681,18.291329031457305,7.085281239336566e-11,0.1319866247066445,212.96750332637174,10.116797156028772,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-660M,Risen Energy Co Ltd,Mono-c-Si,0,660.0,619.9,2.91,,,22.0,18.33,45.75,17.32,38.12,0.0099594222,-0.1256661,43.1,1.7511523339215354,18.340789797852107,8.170393270436463e-11,0.1296218551865942,220.205113207777,11.40856234696528,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-665BHDG,Risen Energy Co Ltd,Mono-c-Si,1,665.0,633.5,3.11,,,11.0,17.22,49.2,16.14,41.25,0.002157666,-0.11003088000000001,43.9,1.5823462994657367,17.251505724227137,5.248533027310511e-13,0.17375810708564446,94.97050703301029,-8.521032343667706,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-665BMDG,Risen Energy Co Ltd,Mono-c-Si,1,665.0,624.6,2.91,,,22.0,18.33,46.09,17.32,38.41,0.0099761025,-0.126646102,43.4,1.7549860807785531,18.341126707389357,7.124797827515096e-11,0.13131958237742555,216.3342583081351,10.141459507537554,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-665M,Risen Energy Co Ltd,Mono-c-Si,0,665.0,624.7,2.91,,,22.0,18.38,45.95,17.37,38.3,0.0099865892,-0.12621546,43.1,1.7589881568575236,18.390591375454154,8.215928395447453e-11,0.12895791783266414,223.79025205101914,11.43355120198417,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-670BHDG,Risen Energy Co Ltd,Mono-c-Si,1,670.0,638.4,3.11,,,11.0,17.31,49.29,16.23,41.33,0.002168943,-0.110232156,43.9,1.5850827044536684,17.34118069250641,5.26169537446848e-13,0.17286123933376094,95.96413076987093,-8.544112646224733,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-670BMDG,Risen Energy Co Ltd,Mono-c-Si,1,670.0,629.4,2.91,,,22.0,18.38,46.29,17.37,38.59,0.010003315,-0.12719566200000001,43.4,1.7627790043373217,18.39092674038552,7.164240630432217e-11,0.13065655556851716,219.77895077765922,10.165849843245272,-0.36139,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-670M,Risen Energy Co Ltd,Mono-c-Si,0,670.0,629.5,2.91,,,22.0,18.43,46.15,17.42,38.48,0.0100137562,-0.12676482,43.1,1.7668233872586525,18.44039529048976,8.26138112763743e-11,0.12829797448598235,227.46182275758864,11.458234494245533,-0.36643,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-675BHDG,Risen Energy Co Ltd,Mono-c-Si,1,675.0,643.2,3.11,,,11.0,17.4,49.38,16.32,41.41,0.0021802199999999996,-0.11043343200000001,43.9,1.5878206973366382,17.430857032357846,5.274958025746455e-13,0.17197340487697052,96.97423946809728,-8.566163276303612,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-680BHDG,Risen Energy Co Ltd,Mono-c-Si,1,680.0,648.1,3.11,,,11.0,17.48,49.47,16.41,41.48,0.002190244,-0.110634708,43.9,1.590011720546717,17.509895730853366,5.232445363540435e-13,0.17188742597264825,100.50238346961002,-8.66965385551976,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-685BHDG,Risen Energy Co Ltd,Mono-c-Si,1,685.0,653.0,3.11,,,11.0,17.56,49.56,16.5,41.56,0.0022002679999999996,-0.11083598400000001,43.9,1.5923732606510876,17.58882936571639,5.207536052917821e-13,0.17111861053070343,104.22854359056056,-8.746562586413749,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-690BHDG,Risen Energy Co Ltd,Mono-c-Si,1,690.0,657.8,3.11,,,11.0,17.66,49.65,16.6,41.63,0.002212798,-0.11103726,43.9,1.5949308218903824,17.688578869203642,5.205415080884426e-13,0.1708341996468537,105.56512699245317,-8.794965472082069,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-695BHDG,Risen Energy Co Ltd,Mono-c-Si,1,695.0,662.7,3.11,,,11.0,17.74,49.74,16.68,41.71,0.0022228219999999997,-0.111238536,43.9,1.5977033976283728,17.768291027778247,5.218628557081119e-13,0.17006968112670892,106.64286102110579,-8.812031528502434,-0.26623,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-700BHDG,Risen Energy Co Ltd,Mono-c-Si,1,700.0,663.5,3.11,,,11.0,17.82,49.83,16.77,41.78,0.0083754,-0.11630322,43.3,1.7688806476070813,17.83938968550924,1.0187281358353618e-11,0.14673266590370618,134.853972223866,11.228464494816402,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-705BHDG,Risen Energy Co Ltd,Mono-c-Si,1,705.0,668.3,3.11,,,11.0,17.91,49.92,16.86,41.86,0.0084177,-0.11651328000000001,43.3,1.771910193526815,17.929099127545513,1.021552103226905e-11,0.14597099029906965,136.88271544273906,11.20628145444998,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-710BHDG,Risen Energy Co Ltd,Mono-c-Si,1,710.0,673.2,3.11,,,11.0,18.0,50.01,16.95,41.93,0.00846,-0.11672334,43.3,1.7747379199885345,18.018880625425965,1.0211107310748886e-11,0.1458894787789119,139.08493247328454,11.155836436123911,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-715BHDG,Risen Energy Co Ltd,Mono-c-Si,1,715.0,678.0,3.11,,,11.0,18.08,50.09,17.03,42.01,0.0084976,-0.11691006,43.3,1.7776144905619111,18.098561554541988,1.0265604342174701e-11,0.14462704681893465,140.87489307099088,11.162745637151575,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-720BHDG,Risen Energy Co Ltd,Mono-c-Si,1,720.0,682.9,3.11,,,11.0,18.19,50.18,17.13,42.08,0.008549300000000001,-0.11712012000000001,43.3,1.780870615126975,18.20895428523696,1.033579633107928e-11,0.14436298660159624,138.54190217268936,11.17051841364454,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-725BHDG,Risen Energy Co Ltd,Mono-c-Si,1,725.0,687.8,3.11,,,11.0,18.29,50.26,17.23,42.14,0.008596300000000001,-0.11730683999999998,43.3,1.783288649764139,18.30871764198168,1.032793358585995e-11,0.1442917627630833,140.99512894877952,11.111754519073942,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +Risen Energy Co Ltd RSM132-8-730BHDG,Risen Energy Co Ltd,Mono-c-Si,1,730.0,692.6,3.11,,,11.0,18.38,50.33,17.32,42.2,0.0086386,-0.11747021999999999,43.3,1.7855510008525879,18.39845066209768,1.03461817051323e-11,0.14371656119317858,143.16615774041534,11.081887937009643,-0.3097,N,2025.7.3,6/23/2025,4.0,bootstrapping +RNG International Inc RSP235D-64,RNG International Inc,Mono-c-Si,0,235.0,221.5,1.17,,,32.0,13.57,21.87,12.7,18.51,0.004681650000000001,-0.06311682,43.2,0.7964500070266561,13.585140249517995,1.5691874342085375e-11,0.06620646018747992,59.33995114419209,-4.664785807216902,-0.3281,N,2025.7.3,6/23/2025,4.0,bootstrapping +RNG International Inc RSP235D-BB-64,RNG International Inc,Mono-c-Si,0,235.0,221.5,1.17,,,32.0,13.46,22.1,12.64,18.77,0.0046437000000000015,-0.06378060000000002,43.2,0.8048838545762097,13.471806993226902,1.5653044106456185e-11,0.0617560147584612,70.40197989067553,-4.633529702027922,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP235D-BK-64,RNG International Inc,Mono-c-Si,0,235.0,221.5,1.17,,,32.0,13.57,21.87,12.7,18.51,0.004681650000000001,-0.06311682,43.2,0.7964500070266561,13.585140249517995,1.5691874342085375e-11,0.06620646018747992,59.33995114419209,-4.664785807216902,-0.3281,N,2025.7.3,6/23/2025,4.0,bootstrapping +RNG International Inc RSP240D-64,RNG International Inc,Mono-c-Si,0,240.0,226.3,1.17,,,32.0,13.64,22.1,12.79,18.77,0.004705800000000001,-0.06378060000000002,43.2,0.8054858233332801,13.652850504518002,1.6162997851674223e-11,0.060836312353294224,64.57390845755903,-4.482112936104935,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP240D-BB-64,RNG International Inc,Mono-c-Si,0,240.0,226.3,1.17,,,32.0,13.57,22.28,12.7,18.95,0.004681650000000001,-0.06430008000000001,43.2,0.8134295078653954,13.583401231464343,1.6808053027751604e-11,0.05906499130063179,59.80882695517452,-4.130152354615434,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP240D-BK-64,RNG International Inc,Mono-c-Si,0,240.0,226.3,1.17,,,32.0,13.64,22.1,12.79,18.77,0.004705800000000001,-0.06378060000000002,43.2,0.8054858233332801,13.652850504518002,1.6162997851674223e-11,0.060836312353294224,64.57390845755903,-4.482112936104935,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP245D-64,RNG International Inc,Mono-c-Si,0,245.0,231.1,1.17,,,32.0,13.73,22.38,12.93,18.95,0.004736850000000001,-0.06458868000000001,43.2,0.8126739374571447,13.741081241439362,1.4772422419164383e-11,0.06661798447929831,82.5417381657466,-5.246004121066614,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP245D-BB-64,RNG International Inc,Mono-c-Si,0,245.0,231.1,1.17,,,32.0,13.61,22.61,12.79,19.13,0.00469545,-0.06525246,43.2,0.8215645564597527,13.622574864271943,1.4874357815245667e-11,0.06907971338069038,74.76620670882005,-5.117226894086125,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP245D-BK-64,RNG International Inc,Mono-c-Si,0,245.0,231.1,1.17,,,32.0,13.71,22.28,12.93,18.95,0.00472995,-0.06430008000000001,43.2,0.8102924069938364,13.719119624536564,1.541116809612453e-11,0.05902172932925823,88.73039763584835,-4.913039650516557,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP310D-84,RNG International Inc,Mono-c-Si,0,310.0,292.2,1.53,,,42.0,13.57,28.7,12.74,24.35,0.004681650000000001,-0.0828282,43.2,1.044833737344303,13.582369657125458,1.5603343085113134e-11,0.08181704149811082,89.75651018627886,-4.720391158229462,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP310D-BB-84,RNG International Inc,Mono-c-Si,0,310.0,292.2,1.53,,,42.0,13.44,29.01,12.61,24.61,0.0046368,-0.08372286000000001,43.2,1.0563874057988414,13.452670360586865,1.5550595670805457e-11,0.0837169063492007,88.80214704583534,-4.669623692533057,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP310D-BK-84,RNG International Inc,Mono-c-Si,0,310.0,292.2,1.53,,,42.0,13.57,28.7,12.74,24.35,0.004681650000000001,-0.0828282,43.2,1.044833737344303,13.582369657125458,1.5603343085113134e-11,0.08181704149811082,89.75651018627886,-4.720391158229462,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP315D-84,RNG International Inc,Mono-c-Si,0,315.0,297.1,1.53,,,42.0,13.64,29.01,12.79,24.63,0.004705800000000001,-0.08372286000000001,43.2,1.0621600835492124,13.652711908804246,1.8311865273012748e-11,0.07975510411858078,85.57799145091093,-3.511744227653671,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP315D-BB-84,RNG International Inc,Mono-c-Si,0,315.0,297.1,1.53,,,42.0,13.57,29.23,12.7,24.82,0.004681650000000001,-0.08435778000000001,43.2,1.0662618282553127,13.583994272846992,1.6422911249073056e-11,0.08120680590810361,78.7448101497351,-4.310808018016293,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP315D-BK-84,RNG International Inc,Mono-c-Si,0,315.0,297.1,1.53,,,42.0,13.64,29.01,12.79,24.63,0.004705800000000001,-0.08372286000000001,43.2,1.0621600835492124,13.652711908804246,1.8311865273012748e-11,0.07975510411858078,85.57799145091093,-3.511744227653671,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RNG-320D,RNG International Inc,Mono-c-Si,0,320.0,300.4,1.62,,,54.0,11.13,36.61,10.47,30.56,0.00546483,-0.11081847,43.1,1.380150354731152,11.140261059042498,3.303176740311869e-11,0.16963482542563288,184.0000741599688,-2.156643677973859,-0.3494,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP320D-84,RNG International Inc,Mono-c-Si,0,320.0,301.9,1.53,,,42.0,13.71,29.24,12.88,24.84,0.00472995,-0.08438664,43.2,1.0693172289966206,13.721500165505507,1.7859423200278152e-11,0.07894532624556255,94.11520427707498,-3.7545408535960303,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP320D-BB-84,RNG International Inc,Mono-c-Si,0,320.0,301.9,1.53,,,42.0,13.66,29.39,12.78,25.06,0.0047127,-0.08481954,43.2,1.0745713650373747,13.672750126721448,1.7595203278814944e-11,0.07175563665365058,76.87625546976034,-3.823042540737734,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP320D-BK-84,RNG International Inc,Mono-c-Si,0,320.0,301.9,1.53,,,42.0,13.71,29.24,12.88,24.84,0.00472995,-0.08438664,43.2,1.0693172289966206,13.721500165505507,1.7859423200278152e-11,0.07894532624556255,94.11520427707498,-3.7545408535960303,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP325D-84,RNG International Inc,Mono-c-Si,0,325.0,306.7,1.53,,,42.0,13.97,29.47,12.97,25.06,0.004819650000000001,-0.08505042000000002,43.2,1.0802372360973684,13.988464437287792,1.9118564594376813e-11,0.07555605262217009,57.16491873105437,-3.3193262882701657,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP325D-BB-84,RNG International Inc,Mono-c-Si,0,325.0,306.7,1.53,,,42.0,13.97,29.47,12.97,25.06,0.004819650000000001,-0.08505042000000002,43.2,1.0802372360973684,13.988464437287792,1.9118564594376813e-11,0.07555605262217009,57.16491873105437,-3.3193262882701657,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP325D-BK-84,RNG International Inc,Mono-c-Si,0,325.0,306.7,1.53,,,42.0,13.97,29.47,12.97,25.06,0.004819650000000001,-0.08505042000000002,43.2,1.0802372360973684,13.988464437287792,1.9118564594376813e-11,0.07555605262217009,57.16491873105437,-3.3193262882701657,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP350D-96,RNG International Inc,Mono-c-Si,0,350.0,329.9,1.73,,,48.0,13.44,32.68,12.7,27.55,0.0046368,-0.09431448,43.2,1.1851766241261605,13.449256053599004,1.4022670289011979e-11,0.11006840581745006,159.82182513640262,-5.4980590015953545,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP350D-BB-96,RNG International Inc,Mono-c-Si,0,350.0,329.9,1.73,,,48.0,13.39,32.92,12.57,27.83,0.004619550000000001,-0.09500712000000003,43.2,1.1963137447311287,13.4032995403138,1.4657850357333682e-11,0.10424007896240159,104.9491307385391,-5.1006753566084635,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP355D-96,RNG International Inc,Mono-c-Si,0,355.0,334.7,1.73,,,48.0,13.5,32.92,12.75,27.83,0.004657500000000001,-0.09500712000000003,43.2,1.1927447299672418,13.509310078550302,1.3706802205955477e-11,0.10392868837804782,150.70090872136413,-5.70323865490008,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP355D-BB-96,RNG International Inc,Mono-c-Si,0,355.0,334.7,1.73,,,48.0,13.44,33.29,12.63,28.11,0.0046368,-0.09607494,43.2,1.2084191096488692,13.452966383919437,1.4289095515522921e-11,0.1080871345710188,112.0351750629731,-5.329999038086642,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP360D-96,RNG International Inc,Mono-c-Si,0,360.0,339.6,1.73,,,48.0,13.64,33.06,12.83,28.06,0.004705800000000001,-0.09541116000000001,43.2,1.2026575709772274,13.6511616915849,1.5397143800956352e-11,0.09298797572884174,113.63474644947065,-4.870483838879036,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP360D-BB-96,RNG International Inc,Mono-c-Si,0,360.0,339.6,1.73,,,48.0,13.5,33.43,12.75,28.11,0.004657500000000001,-0.09647898,43.2,1.207947838208672,13.510243058954972,1.2724683545710181e-11,0.11909813255370819,156.96724993099207,-6.272968329691214,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP365D-96,RNG International Inc,Mono-c-Si,0,365.0,344.4,1.73,,,48.0,13.81,33.15,12.95,28.21,0.004764450000000001,-0.09567090000000002,43.2,1.4180532055467823,13.028807478103332,5.511150524838457e-10,0.10445140979783543,270.9680395174394,-98.9750112371519,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP365D-BB-96,RNG International Inc,Mono-c-Si,0,365.0,344.4,1.73,,,48.0,13.81,33.15,12.95,28.21,0.004764450000000001,-0.09567090000000002,43.2,1.4180532055467823,13.028807478103332,5.511150524838457e-10,0.10445140979783543,270.9680395174394,-98.9750112371519,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP370D-96,RNG International Inc,Mono-c-Si,0,370.0,349.2,1.73,,,48.0,13.97,33.26,13.04,28.37,0.004819650000000001,-0.09598836000000001,43.2,1.2177229716786588,13.984102557269383,1.8624907974557326e-11,0.07823682602104942,77.50143755740476,-3.5447142750318266,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP370D-BB-96,RNG International Inc,Mono-c-Si,0,370.0,349.2,1.73,,,48.0,13.97,33.26,13.04,28.37,0.004819650000000001,-0.09598836000000001,43.2,1.2177229716786588,13.984102557269383,1.8624907974557326e-11,0.07823682602104942,77.50143755740476,-3.5447142750318266,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP400D-108,RNG International Inc,Mono-c-Si,0,400.0,377.2,1.94,,,54.0,13.76,37.16,12.92,31.02,0.0047472,-0.10724376000000001,43.2,1.3416004591480313,13.77699168527437,1.2594093778957134e-11,0.1494948710102887,121.06211986624191,-6.475915729528849,-0.3281,N,2025.7.3,6/23/2025,4.0,bootstrapping +RNG International Inc RSP400D-BB-108,RNG International Inc,Mono-c-Si,0,400.0,377.2,1.94,,,54.0,13.76,37.16,12.92,31.02,0.0047472,-0.10724376000000001,43.2,1.3416004591480313,13.77699168527437,1.2594093778957134e-11,0.1494948710102887,121.06211986624191,-6.475915729528849,-0.3281,N,2025.7.3,6/23/2025,4.0,bootstrapping +RNG International Inc RSP400D-BK-108,RNG International Inc,Mono-c-Si,0,400.0,377.2,1.94,,,54.0,13.76,37.16,12.92,31.02,0.0047472,-0.10724376000000001,43.2,1.3416004591480313,13.77699168527437,1.2594093778957134e-11,0.1494948710102887,121.06211986624191,-6.475915729528849,-0.3281,N,2025.7.3,6/23/2025,4.0,bootstrapping +RNG International Inc RSP405D-108,RNG International Inc,Mono-c-Si,0,405.0,382.0,1.94,,,54.0,13.87,37.31,13.02,31.09,0.00478515,-0.10767666000000002,43.2,1.3459670406248512,13.887826299737881,1.2422066791366113e-11,0.15375568791745467,119.63174802342608,-6.640533848134586,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP405D-BB-108,RNG International Inc,Mono-c-Si,0,405.0,382.0,1.94,,,54.0,13.87,37.31,13.02,31.09,0.00478515,-0.10767666000000002,43.2,1.3459670406248512,13.887826299737881,1.2422066791366113e-11,0.15375568791745467,119.63174802342608,-6.640533848134586,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP405D-BK-108,RNG International Inc,Mono-c-Si,0,405.0,382.0,1.94,,,54.0,13.87,37.31,13.02,31.09,0.00478515,-0.10767666000000002,43.2,1.3459670406248512,13.887826299737881,1.2422066791366113e-11,0.15375568791745467,119.63174802342608,-6.640533848134586,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP410D-108,RNG International Inc,Mono-c-Si,0,410.0,386.9,1.94,,,54.0,13.96,37.46,13.13,31.22,0.0048162000000000005,-0.10810956000000002,43.2,1.3502103754704962,13.976024923691094,1.2234149988870258e-11,0.1530448572785016,133.32395555190416,-6.8128371712196305,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP410D-BB-108,RNG International Inc,Mono-c-Si,0,410.0,386.9,1.94,,,54.0,13.96,37.46,13.13,31.22,0.0048162000000000005,-0.10810956000000002,43.2,1.3502103754704962,13.976024923691094,1.2234149988870258e-11,0.1530448572785016,133.32395555190416,-6.8128371712196305,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP410D-BK-108,RNG International Inc,Mono-c-Si,0,410.0,386.9,1.94,,,54.0,13.96,37.46,13.13,31.22,0.0048162000000000005,-0.10810956000000002,43.2,1.3502103754704962,13.976024923691094,1.2234149988870258e-11,0.1530448572785016,133.32395555190416,-6.8128371712196305,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP415D-108,RNG International Inc,Mono-c-Si,0,415.0,391.7,1.94,,,54.0,14.12,37.54,13.24,31.35,0.0048714000000000006,-0.10834044000000001,43.2,1.3565042697296106,14.138598837239698,1.3218359142359263e-11,0.14598444778209116,110.82953097420445,-6.298774667077173,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP415D-BB-108,RNG International Inc,Mono-c-Si,0,415.0,391.7,1.94,,,54.0,14.12,37.54,13.24,31.35,0.0048714000000000006,-0.10834044000000001,43.2,1.3565042697296106,14.138598837239698,1.3218359142359263e-11,0.14598444778209116,110.82953097420445,-6.298774667077173,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP415D-BK-108,RNG International Inc,Mono-c-Si,0,415.0,391.7,1.94,,,54.0,14.12,37.54,13.24,31.35,0.0048714000000000006,-0.10834044000000001,43.2,1.3565042697296106,14.138598837239698,1.3218359142359263e-11,0.14598444778209116,110.82953097420445,-6.298774667077173,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP420D-108,RNG International Inc,Mono-c-Si,0,420.0,396.5,1.94,,,54.0,14.26,37.62,13.35,31.48,0.004919700000000001,-0.10857132,43.2,1.3618566153558933,14.27962252971966,1.4005329046086245e-11,0.13933201966681957,101.25476332400541,-5.925794382828929,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP420D-BB-108,RNG International Inc,Mono-c-Si,0,420.0,396.5,1.94,,,54.0,14.26,37.62,13.35,31.48,0.004919700000000001,-0.10857132,43.2,1.3618566153558933,14.27962252971966,1.4005329046086245e-11,0.13933201966681957,101.25476332400541,-5.925794382828929,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP420D-BK-108,RNG International Inc,Mono-c-Si,0,420.0,396.5,1.94,,,54.0,14.26,37.62,13.35,31.48,0.004919700000000001,-0.10857132,43.2,1.3618566153558933,14.27962252971966,1.4005329046086245e-11,0.13933201966681957,101.25476332400541,-5.925794382828929,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP445D-120,RNG International Inc,Mono-c-Si,0,445.0,419.7,2.15,,,60.0,13.82,41.1,12.91,34.48,0.004767900000000001,-0.11861460000000001,43.2,1.4913885801098312,13.839978962042984,1.4456615175402783e-11,0.149079306516819,103.12227485348217,-5.433173773107425,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP445D-BB-120,RNG International Inc,Mono-c-Si,0,445.0,419.7,2.15,,,60.0,13.82,41.1,12.91,34.48,0.004767900000000001,-0.11861460000000001,43.2,1.4913885801098312,13.839978962042984,1.4456615175402783e-11,0.149079306516819,103.12227485348217,-5.433173773107425,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP445D-BK-120,RNG International Inc,Mono-c-Si,0,445.0,419.7,2.15,,,60.0,13.82,41.1,12.91,34.48,0.004767900000000001,-0.11861460000000001,43.2,1.4913885801098312,13.839978962042984,1.4456615175402783e-11,0.149079306516819,103.12227485348217,-5.433173773107425,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP450D-120,RNG International Inc,Mono-c-Si,0,450.0,424.5,2.15,,,60.0,13.89,41.25,12.98,34.67,0.00479205,-0.11904750000000001,43.2,1.4979885997046436,13.909110952725781,1.484611753061105e-11,0.14323299766904657,104.10293882844823,-5.268416481953802,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP450D-BB-120,RNG International Inc,Mono-c-Si,0,450.0,424.5,2.15,,,60.0,13.89,41.25,12.98,34.67,0.00479205,-0.11904750000000001,43.2,1.4979885997046436,13.909110952725781,1.484611753061105e-11,0.14323299766904657,104.10293882844823,-5.268416481953802,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP450D-BK-120,RNG International Inc,Mono-c-Si,0,450.0,424.5,2.15,,,60.0,13.89,41.25,12.98,34.67,0.00479205,-0.11904750000000001,43.2,1.4979885997046436,13.909110952725781,1.484611753061105e-11,0.14323299766904657,104.10293882844823,-5.268416481953802,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP455D-120,RNG International Inc,Mono-c-Si,0,455.0,429.3,2.15,,,60.0,13.97,41.4,13.05,34.87,0.004819650000000001,-0.1194804,43.2,1.5053486443511015,13.988707273348702,1.5453748458107924e-11,0.13640128710234242,101.86016686148007,-5.001507884355413,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP455D-BB-120,RNG International Inc,Mono-c-Si,0,455.0,429.3,2.15,,,60.0,13.97,41.4,13.05,34.87,0.004819650000000001,-0.1194804,43.2,1.5053486443511015,13.988707273348702,1.5453748458107924e-11,0.13640128710234242,101.86016686148007,-5.001507884355413,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP455D-BK-120,RNG International Inc,Mono-c-Si,0,455.0,429.3,2.15,,,60.0,13.97,41.4,13.05,34.87,0.004819650000000001,-0.1194804,43.2,1.5053486443511015,13.988707273348702,1.5453748458107924e-11,0.13640128710234242,101.86016686148007,-5.001507884355413,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP460D-120,RNG International Inc,Mono-c-Si,0,460.0,434.2,2.15,,,60.0,14.07,41.58,13.12,35.08,0.004854150000000001,-0.11999988000000002,43.2,1.5145485382707309,14.089495383555933,1.6296445802145033e-11,0.13073224016677876,94.35067627881538,-4.638763998427117,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP460D-BB-120,RNG International Inc,Mono-c-Si,0,460.0,434.2,2.15,,,60.0,14.07,41.58,13.12,35.08,0.004854150000000001,-0.11999988000000002,43.2,1.5145485382707309,14.089495383555933,1.6296445802145033e-11,0.13073224016677876,94.35067627881538,-4.638763998427117,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP460D-BK-120,RNG International Inc,Mono-c-Si,0,460.0,434.2,2.15,,,60.0,14.07,41.58,13.12,35.08,0.004854150000000001,-0.11999988000000002,43.2,1.5145485382707309,14.089495383555933,1.6296445802145033e-11,0.13073224016677876,94.35067627881538,-4.638763998427117,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP465D-120,RNG International Inc,Mono-c-Si,0,465.0,439.0,2.15,,,60.0,14.15,41.71,13.24,35.13,0.004881750000000001,-0.12037506000000002,43.2,1.515341841611027,14.167692595922738,1.5323543694098825e-11,0.13593854134273245,108.71951027776959,-5.171942527352854,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP465D-BB-120,RNG International Inc,Mono-c-Si,0,465.0,439.0,2.15,,,60.0,14.15,41.71,13.24,35.13,0.004881750000000001,-0.12037506000000002,43.2,1.515341841611027,14.167692595922738,1.5323543694098825e-11,0.13593854134273245,108.71951027776959,-5.171942527352854,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP465D-BK-120,RNG International Inc,Mono-c-Si,0,465.0,439.0,2.15,,,60.0,14.15,41.71,13.24,35.13,0.004881750000000001,-0.12037506000000002,43.2,1.515341841611027,14.167692595922738,1.5323543694098825e-11,0.13593854134273245,108.71951027776959,-5.171942527352854,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP530D-144,RNG International Inc,Mono-c-Si,0,530.0,499.9,2.56,,,72.0,13.74,49.15,12.85,41.27,0.0047403,-0.1418469,43.2,1.783289229037415,13.758619034978818,1.4344905103911207e-11,0.1761716315677148,130.00664244287546,-5.452392236173254,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP530D-BB-144,RNG International Inc,Mono-c-Si,0,530.0,499.9,2.56,,,72.0,13.74,49.15,12.85,41.27,0.0047403,-0.1418469,43.2,1.783289229037415,13.758619034978818,1.4344905103911207e-11,0.1761716315677148,130.00664244287546,-5.452392236173254,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP530D-BK-144,RNG International Inc,Mono-c-Si,0,530.0,499.9,2.56,,,72.0,13.74,49.15,12.85,41.27,0.0047403,-0.1418469,43.2,1.783289229037415,13.758619034978818,1.4344905103911207e-11,0.1761716315677148,130.00664244287546,-5.452392236173254,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP535D-144,RNG International Inc,Mono-c-Si,0,535.0,504.7,2.56,,,72.0,13.82,49.35,12.91,41.45,0.004767900000000001,-0.14242410000000003,43.2,1.7918380767037998,13.839544174829363,1.4697887536124916e-11,0.17466628378894986,123.50933561606678,-5.305562811110746,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP535D-BB-144,RNG International Inc,Mono-c-Si,0,535.0,504.7,2.56,,,72.0,13.82,49.35,12.91,41.45,0.004767900000000001,-0.14242410000000003,43.2,1.7918380767037998,13.839544174829363,1.4697887536124916e-11,0.17466628378894986,123.50933561606678,-5.305562811110746,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP535D-BK-144,RNG International Inc,Mono-c-Si,0,535.0,504.7,2.56,,,72.0,13.82,49.35,12.91,41.45,0.004767900000000001,-0.14242410000000003,43.2,1.7918380767037998,13.839544174829363,1.4697887536124916e-11,0.17466628378894986,123.50933561606678,-5.305562811110746,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP540D-144,RNG International Inc,Mono-c-Si,0,540.0,509.5,2.56,,,72.0,13.89,49.55,12.98,41.62,0.00479205,-0.1430013,43.2,1.7988253817631858,13.909339994165155,1.4716468172473842e-11,0.1743520181012859,125.21976563088333,-5.336083883588473,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP540D-BB-144,RNG International Inc,Mono-c-Si,0,540.0,509.5,2.56,,,72.0,13.89,49.55,12.98,41.62,0.00479205,-0.1430013,43.2,1.7988253817631858,13.909339994165155,1.4716468172473842e-11,0.1743520181012859,125.21976563088333,-5.336083883588473,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP540D-BK-144,RNG International Inc,Mono-c-Si,0,540.0,509.5,2.56,,,72.0,13.89,49.55,12.98,41.62,0.00479205,-0.1430013,43.2,1.7988253817631858,13.909339994165155,1.4716468172473842e-11,0.1743520181012859,125.21976563088333,-5.336083883588473,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP545D-144,RNG International Inc,Mono-c-Si,0,545.0,514.3,2.56,,,72.0,13.97,49.75,13.05,41.8,0.004819650000000001,-0.1435785,43.2,1.8066812869240418,13.989638039812442,1.4929380827587335e-11,0.17295732357459276,123.03742321393948,-5.268245029654298,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP545D-BB-144,RNG International Inc,Mono-c-Si,0,545.0,514.3,2.56,,,72.0,13.97,49.75,13.05,41.8,0.004819650000000001,-0.1435785,43.2,1.8066812869240418,13.989638039812442,1.4929380827587335e-11,0.17295732357459276,123.03742321393948,-5.268245029654298,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP545D-BK-144,RNG International Inc,Mono-c-Si,0,545.0,514.3,2.56,,,72.0,13.97,49.75,13.05,41.8,0.004819650000000001,-0.1435785,43.2,1.8066812869240418,13.989638039812442,1.4929380827587335e-11,0.17295732357459276,123.03742321393948,-5.268245029654298,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP550D-144,RNG International Inc,Mono-c-Si,0,550.0,519.2,2.56,,,72.0,14.05,49.95,13.11,41.97,0.004847250000000001,-0.14415570000000003,43.2,1.8150081331679155,14.070636147467981,1.5238975062137908e-11,0.172364311601201,117.35323110634603,-5.149756871980614,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP550D-BB-144,RNG International Inc,Mono-c-Si,0,550.0,519.2,2.56,,,72.0,14.05,49.95,13.11,41.97,0.004847250000000001,-0.14415570000000003,43.2,1.8150081331679155,14.070636147467981,1.5238975062137908e-11,0.172364311601201,117.35323110634603,-5.149756871980614,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP550D-BK-144,RNG International Inc,Mono-c-Si,0,550.0,519.2,2.56,,,72.0,14.05,49.95,13.11,41.97,0.004847250000000001,-0.14415570000000003,43.2,1.8150081331679155,14.070636147467981,1.5238975062137908e-11,0.172364311601201,117.35323110634603,-5.149756871980614,-0.3281,N,2025.7.3,6/23/2025,4.0,first_pass +RNG International Inc RSP555D-144,RNG International Inc,Mono-c-Si,0,555.0,524.0,2.56,,,72.0,14.1,50.05,13.14,42.27,0.0048645,-0.1444443,43.2,1.8246080179952036,14.119523660694329,1.670063045371965e-11,0.15310127091332656,110.56983410329019,-4.462732143256299,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP555D-BB-144,RNG International Inc,Mono-c-Si,0,555.0,524.0,2.56,,,72.0,14.1,50.05,13.14,42.27,0.0048645,-0.1444443,43.2,1.8246080179952036,14.119523660694329,1.670063045371965e-11,0.15310127091332656,110.56983410329019,-4.462732143256299,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP555D-BK-144,RNG International Inc,Mono-c-Si,0,555.0,524.0,2.56,,,72.0,14.1,50.05,13.14,42.27,0.0048645,-0.1444443,43.2,1.8246080179952036,14.119523660694329,1.670063045371965e-11,0.15310127091332656,110.56983410329019,-4.462732143256299,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP560D-144,RNG International Inc,Mono-c-Si,0,560.0,528.9,2.56,,,72.0,14.18,50.16,13.18,42.52,0.004892100000000001,-0.14476176,43.2,1.8345670697095757,14.199661549411308,1.8295280965921545e-11,0.13853682214145924,99.91339443173423,-3.785805737172232,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP560D-BB-144,RNG International Inc,Mono-c-Si,0,560.0,528.9,2.56,,,72.0,14.18,50.16,13.18,42.52,0.004892100000000001,-0.14476176,43.2,1.8345670697095757,14.199661549411308,1.8295280965921545e-11,0.13853682214145924,99.91339443173423,-3.785805737172232,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RNG International Inc RSP560D-BK-144,RNG International Inc,Mono-c-Si,0,560.0,528.9,2.56,,,72.0,14.18,50.16,13.18,42.52,0.004892100000000001,-0.14476176,43.2,1.8345670697095757,14.199661549411308,1.8295280965921545e-11,0.13853682214145924,99.91339443173423,-3.785805737172232,-0.3281,N,2025.7.3,6/23/2025,2.0,first_pass +RSI Holding RSI-6M-250M-60,RSI Holding,Mono-c-Si,0,250.0,226.3,1.60974,1.626,0.99,60.0,8.97,37.1,8.03,31.1,0.0047497944,-0.12403272,45.02,1.6264040798981214,8.990878173399564,1.0353944663986483e-09,0.13529499851099822,58.1275085778262,19.089815083269862,-0.45395,N,2025.7.3,6/23/2025,4.0,first_pass +RSI Holding RSI-6M-255M-60,RSI Holding,Mono-c-Si,0,255.0,231.0,1.60974,1.626,0.99,60.0,9.12,37.2,8.16,31.3,0.0048292223999999995,-0.12436704000000003,45.02,1.635045904576846,9.138685739375582,1.1159983949167904e-09,0.11635361997098831,56.78903310078627,19.660194253792437,-0.45395,N,2025.7.3,6/23/2025,4.0,first_pass +RSI Holding RSI-6M-260M-60,RSI Holding,Mono-c-Si,0,260.0,235.6,1.60974,1.626,0.99,60.0,9.23,37.4,8.25,31.7,0.0048874696,-0.12503568,45.02,1.652312759348954,9.243637417203882,1.2667690111882258e-09,0.08190128862632476,55.431972448023544,20.789787292203133,-0.45395,N,2025.7.3,6/23/2025,4.0,first_pass +RSI Holding RSI-6M-265M-60,RSI Holding,Mono-c-Si,0,265.0,240.3,1.60974,1.626,0.99,60.0,9.24,38.1,8.33,31.8,0.0048927648,-0.12737592,45.02,1.6586351482667134,9.262083169846553,9.174113250028179e-10,0.15691779954555118,65.65726576918044,17.614101686852642,-0.45395,N,2025.7.3,6/23/2025,4.0,first_pass +RSI Holding RSI-6M-270M-60,RSI Holding,Mono-c-Si,0,270.0,244.9,1.60974,1.626,0.99,60.0,9.39,38.3,8.46,31.9,0.0049721928000000006,-0.12804456,45.02,1.665845072865567,9.414023206303506,9.127757716671531e-10,0.16441858888632319,64.26663537194096,17.41337938711603,-0.45395,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE395-108MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,1,395.0,366.2,1.94,,,54.0,13.39,37.18,12.75,30.98,0.006159400000000001,-0.10499632,45.46,1.416640967169501,13.391316572278344,5.344002516302108e-11,0.14491384003816843,1473.8245836764606,7.450959210493848,-0.3715,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE400-108MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,1,400.0,371.0,1.94,,,54.0,13.47,37.42,12.83,31.17,0.006196200000000001,-0.10567408,45.46,1.4253420181737968,13.471048870222386,5.334244621082414e-11,0.1459014296557624,1873.7232808981312,7.382059038915593,-0.3715,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE440-120MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,1,440.0,408.3,2.15,,,60.0,13.62,40.72,12.97,33.93,0.006455879999999999,-0.11483039999999999,45.46,1.54651393935296,13.621398227548566,4.99248202636101e-11,0.1568448799850526,1527.8110297967476,6.850089396960301,-0.3674,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE445-120MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,1,445.0,413.1,2.15,,,60.0,13.7,40.93,13.05,34.11,0.006493799999999999,-0.11542259999999999,45.46,1.5499143876041588,13.701267206566627,4.6471461153778626e-11,0.15706224778304856,1698.028631368837,6.182203076570135,-0.3674,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE530-144MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,0,530.0,491.6,2.56,,,72.0,13.42,49.8,12.78,41.5,0.006374500000000001,-0.14173080000000002,45.46,1.877472396558631,13.421644604194407,4.0469625465356064e-11,0.19670613047338734,1605.1257068213743,4.2109644724395014,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE535-144MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,0,535.0,496.4,2.56,,,72.0,13.5,49.98,12.86,41.65,0.006412500000000001,-0.14224308,45.46,1.9070029977425051,13.500918111614167,5.591348205891608e-11,0.19235635015428143,2828.4261855382438,6.913417743107517,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE540-144MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,0,540.0,501.2,2.56,,,72.0,13.65,50.16,12.94,41.8,0.006483750000000001,-0.14275536,45.46,1.9184471569831374,13.655160391025772,5.983995890383771e-11,0.19044328724370993,503.75077103403834,7.425553458626801,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy (P) Limited SGE545-144MBHC,Saatvik Green Energy (P) Limited,Mono-c-Si,0,545.0,506.0,2.56,,,72.0,13.67,50.49,13.03,42.08,0.006493250000000001,-0.14369454,45.46,1.925997390545734,13.670393763089415,5.6300822152831465e-11,0.1915200875540279,6648.872469274329,6.862410713588781,-0.3712,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE560-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,560.0,528.7,2.56,,,72.0,13.88,50.68,13.22,42.41,0.00577408,-0.11549972,46.1,1.721221130477852,13.886188924933546,2.2478214984369833e-12,0.21100455380932465,473.2232568444329,2.7006137007210986,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE565-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,565.0,533.5,2.56,,,72.0,13.96,50.86,13.3,42.53,0.00580736,-0.11590994,46.1,1.7265523912839391,13.965964914629504,2.231713445387081e-12,0.21315941464836838,498.8680674755841,2.5885368384916716,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE570-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,570.0,538.4,2.56,,,72.0,14.04,51.04,13.37,42.65,0.005840639999999999,-0.11632015999999999,46.1,1.7324463650580548,14.046494030590374,2.235190083611952e-12,0.21526697486701626,465.40408017660434,2.5550094315805887,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE575-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,575.0,543.2,2.56,,,72.0,14.1,51.22,13.43,42.82,0.0058655999999999995,-0.11673038,46.1,1.7387586009765237,14.106288070144332,2.252923551970351e-12,0.21346017616915855,478.6505907552899,2.5852036635912135,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE580-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,580.0,548.0,2.56,,,72.0,14.19,51.41,13.51,42.94,0.00590304,-0.11716338999999999,46.1,1.7448084757188307,14.196798135105182,2.2511171344587386e-12,0.21613828249138706,451.1534680342656,2.5257607405446505,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE585-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,585.0,552.9,2.56,,,72.0,14.26,51.59,13.59,42.94,0.00593216,-0.11757361,46.1,1.7473842971691078,14.26586344054291,2.1344937852051933e-12,0.22839531674777752,555.4617978501229,2.0251653206284383,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE590-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,590.0,557.7,2.56,,,72.0,14.33,51.77,13.67,43.18,0.00596128,-0.11798383000000001,46.1,1.7544178766271032,14.334815496996939,2.181107200925543e-12,0.22060650234304127,656.4828490221993,2.1633188170609574,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE595-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,595.0,562.6,2.56,,,72.0,14.43,51.95,13.74,43.3,0.00600288,-0.11839405000000001,46.1,1.7613618050843542,14.43687224704958,2.2229674973035527e-12,0.2222886684032706,466.75060835350814,2.274366056748786,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE600-132TGG,Saatvik Green Energy Limited,Mono-c-Si,1,600.0,566.7,2.68,,,61.0,15.85,47.98,14.96,40.11,0.00600715,-0.10901056,46.1,1.6288399884393776,15.867672260095912,2.5085697873405415e-12,0.1787024870575869,160.27573205967312,2.9217478828984227,-0.2843,N,2025.7.3,6/23/2025,2.0,first_pass +Saatvik Green Energy Limited SGE600-144TGG,Saatvik Green Energy Limited,Mono-C-si,1,600.0,567.4,2.56,,,72.0,14.51,52.13,13.82,43.42,0.00603616,-0.11880426999999999,46.1,1.7666957276242037,14.51662338460914,2.2076281756727524e-12,0.22429722299535093,491.373056917925,2.1668582059762898,-0.2839,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE605-132TGG,Saatvik Green Energy Limited,Mono-c-Si,1,605.0,571.6,2.68,,,61.0,15.9,48.18,15.01,40.31,0.0060261,-0.10946496000000001,46.1,1.6361076511115358,15.917327476769149,2.5386023315812047e-12,0.1764102969852411,161.87721722813907,2.996052572326681,-0.2843,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE610-132TGG,Saatvik Green Energy Limited,Mono-c-Si,1,610.0,576.4,2.68,,,61.0,15.95,48.38,15.06,40.51,0.006045050000000001,-0.10991936000000002,46.1,1.6433745092553012,15.966987588030893,2.56873500574754e-12,0.1741337878218369,163.4978381018825,3.069622765437285,-0.2843,N,2025.7.3,6/23/2025,2.0,first_pass +Saatvik Green Energy Limited SGE615-132TGG,Saatvik Green Energy Limited,Mono-c-Si,1,615.0,581.2,2.68,,,61.0,16.0,48.58,15.11,40.71,0.006064000000000001,-0.11037376000000002,46.1,1.6506405315326929,16.016652500260385,2.598964811258889e-12,0.1718728034414464,165.13825598896722,3.1424624654747606,-0.2843,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE620-132TGG,Saatvik Green Energy Limited,Mono-c-Si,1,620.0,586.1,2.68,,,61.0,16.05,48.78,15.16,40.91,0.006082950000000001,-0.11082816000000001,46.1,1.6579058049484472,16.06632221805582,2.6292939775718183e-12,0.16962717314543754,166.79817129783072,3.214593868089417,-0.2843,N,2025.7.3,6/23/2025,4.0,first_pass +Saatvik Green Energy Limited SGE625-132TGG,Saatvik Green Energy Limited,Mono-c-Si,1,625.0,590.9,2.68,,,61.0,16.1,48.98,15.21,41.11,0.0061019,-0.11128256,46.1,1.6651702733804807,16.115996630401277,2.6597184505923657e-12,0.16739674858674192,168.4784599287818,3.2860172674388632,-0.2843,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-240WB,SEG Solar Inc,Multi-c-Si,0,240.0,216.2,1.63,,,1.0,8.6,36.9,8.06,29.8,0.0036722,-0.09678869999999999,45.5,1.5147145966399786,8.609054346694522,2.2338467992054656e-10,0.326551930260402,310.1656108533484,34.68127637749248,-0.4573,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PB-240WW,SEG Solar Inc,Multi-c-Si,0,240.0,216.2,1.63,,,1.0,8.6,36.9,8.06,29.8,0.0036722,-0.09678869999999999,45.5,1.5147145966399786,8.609054346694522,2.2338467992054656e-10,0.326551930260402,310.1656108533484,34.68127637749248,-0.4573,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PB-245WB,SEG Solar Inc,Multi-c-Si,0,245.0,220.9,1.63,,,1.0,8.76,37.0,8.21,29.9,0.00374052,-0.09705099999999998,45.5,1.5193441784945447,8.76918623038115,2.294470330866178e-10,0.31870366373594117,303.9162223734022,34.77214237664409,-0.4573,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PB-245WW,SEG Solar Inc,Multi-c-Si,0,245.0,220.9,1.63,,,1.0,8.76,37.0,8.21,29.9,0.00374052,-0.09705099999999998,45.5,1.5193441784945447,8.76918623038115,2.294470330866178e-10,0.31870366373594117,303.9162223734022,34.77214237664409,-0.4573,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PB-250WB,SEG Solar Inc,Multi-c-Si,0,250.0,225.5,1.63,,,1.0,8.92,37.1,8.35,29.9,0.0038088400000000004,-0.09731329999999999,45.5,1.522133841885301,8.930541874163412,2.2851596960383448e-10,0.325162133073656,275.13576244303096,34.536157459692774,-0.4573,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PB-250WW,SEG Solar Inc,Multi-c-Si,0,250.0,225.5,1.63,,,1.0,8.92,37.1,8.35,29.9,0.0038088400000000004,-0.09731329999999999,45.5,1.522133841885301,8.930541874163412,2.2851596960383448e-10,0.325162133073656,275.13576244303096,34.536157459692774,-0.4573,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PB-255BB,SEG Solar Inc,Multi-c-Si,0,255.0,229.6,1.63,,,1.0,8.65,37.6,8.37,30.5,0.00519,-0.14100000000000001,45.8,1.6128602426303773,8.650001620459769,6.493390543188785e-10,0.1872011905624572,999992.941753559,2.1679935664939216,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-255BW,SEG Solar Inc,Multi-c-Si,0,255.0,229.6,1.63,,,1.0,8.65,37.6,8.37,30.5,0.00519,-0.14100000000000001,45.8,1.6128602426303773,8.650001620459769,6.493390543188785e-10,0.1872011905624572,999992.941753559,2.1679935664939216,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-255WB,SEG Solar Inc,Multi-c-Si,0,255.0,230.1,1.63,,,1.0,8.65,37.6,8.37,30.5,0.0036935500000000003,-0.0986248,45.5,1.5529207566664451,8.650161740045368,2.639533916434426e-10,0.2100521484847171,11233.814326522217,36.38665213149121,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-255WW,SEG Solar Inc,Multi-c-Si,0,255.0,230.1,1.63,,,1.0,8.65,37.6,8.37,30.5,0.0036935500000000003,-0.0986248,45.5,1.5529207566664451,8.650161740045368,2.639533916434426e-10,0.2100521484847171,11233.814326522217,36.38665213149121,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPB-255BB,SEG Solar Inc,Multi-c-Si,0,255.0,232.3,1.64,,,60.0,8.79,37.0,8.28,30.8,0.00364785,-0.113516,47.3,1.4333901596361278,8.796598000186735,5.3403666135978134e-11,0.21817927040726254,290.66318261754225,2.360510484180928,-0.3826,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-260WB,SEG Solar Inc,Mono-c-Si,0,260.0,234.4,1.63,,,1.0,8.88,38.1,8.61,30.2,0.0031257600000000004,-0.0926592,45.8,1.546267251675564,8.880231342161085,1.7670423982785243e-10,0.28845294147192163,11072.21592765706,42.26861403584344,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-260WW,SEG Solar Inc,Mono-c-Si,0,260.0,234.4,1.63,,,1.0,8.88,38.1,8.61,30.2,0.0031257600000000004,-0.0926592,45.8,1.546267251675564,8.880231342161085,1.7670423982785243e-10,0.28845294147192163,11072.21592765706,42.26861403584344,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-260BB,SEG Solar Inc,Multi-c-Si,0,260.0,234.2,1.63,,,1.0,8.72,38.0,8.42,30.9,0.0052320000000000005,-0.14250000000000002,45.8,1.6302415906067853,8.72000166499834,6.56687041785558e-10,0.1908064251672025,999999.9113696065,2.194421632175465,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-260BW,SEG Solar Inc,Multi-c-Si,0,260.0,234.2,1.63,,,1.0,8.72,38.0,8.42,30.9,0.0052320000000000005,-0.14250000000000002,45.8,1.6302415906067853,8.72000166499834,6.56687041785558e-10,0.1908064251672025,999999.9113696065,2.194421632175465,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-260WB,SEG Solar Inc,Multi-c-Si,0,260.0,234.8,1.63,,,1.0,8.72,38.0,8.42,30.9,0.0037234400000000006,-0.099674,45.5,1.569736330209155,8.720165561107164,2.6730340359607956e-10,0.21339505279362764,11239.425034454893,36.43668284776718,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-260WW,SEG Solar Inc,Multi-c-Si,0,260.0,234.8,1.63,,,1.0,8.72,38.0,8.42,30.9,0.0037234400000000006,-0.099674,45.5,1.569736330209155,8.720165561107164,2.6730340359607956e-10,0.21339505279362764,11239.425034454893,36.43668284776718,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPB-260BB,SEG Solar Inc,Multi-c-Si,0,260.0,237.0,1.64,,,60.0,8.96,37.2,8.39,31.0,0.0037184000000000006,-0.11412960000000003,47.3,1.4464307970483685,8.969895124575897,5.940267816372207e-11,0.20975724648923053,189.9344411776375,3.1066964460642055,-0.3826,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-260WB,SEG Solar Inc,Multi-c-Si,0,260.0,237.0,1.64,,,60.0,8.96,37.2,8.39,31.0,0.0037273600000000003,-0.12112320000000001,45.8,1.4950618086232983,8.968568898314173,1.3734694667032636e-10,0.19717990026562404,206.17959340616724,3.8883415527722,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-260WW,SEG Solar Inc,Multi-c-Si,0,260.0,237.0,1.64,,,60.0,8.96,37.2,8.39,31.0,0.0037273600000000003,-0.12112320000000001,45.8,1.4950618086232983,8.968568898314173,1.3734694667032636e-10,0.19717990026562404,206.17959340616724,3.8883415527722,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-265WB,SEG Solar Inc,Mono-c-Si,0,265.0,239.0,1.63,,,1.0,8.96,38.3,8.69,30.5,0.0031539200000000006,-0.0931456,45.8,1.5576633864740865,8.960182889038618,1.8779965501220288e-10,0.26835058084842467,13146.504820750515,42.86364149381309,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-265WW,SEG Solar Inc,Mono-c-Si,0,265.0,239.0,1.63,,,1.0,8.96,38.3,8.69,30.5,0.0031539200000000006,-0.0931456,45.8,1.5576633864740865,8.960182889038618,1.8779965501220288e-10,0.26835058084842467,13146.504820750515,42.86364149381309,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-265BB,SEG Solar Inc,Multi-c-Si,0,265.0,238.9,1.63,,,1.0,8.83,38.3,8.53,31.1,0.005298,-0.143625,45.8,1.6423392646726835,8.830001704296764,6.577186229600188e-10,0.19287638380628186,999999.9096750566,2.103676501356847,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-265BW,SEG Solar Inc,Multi-c-Si,0,265.0,238.9,1.63,,,1.0,8.83,38.3,8.53,31.1,0.005298,-0.143625,45.8,1.6423392646726835,8.830001704296764,6.577186229600188e-10,0.19287638380628186,999999.9096750566,2.103676501356847,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-265WB,SEG Solar Inc,Multi-c-Si,0,265.0,239.4,1.63,,,60.0,8.83,38.3,8.53,31.1,0.0037704100000000005,-0.10046089999999999,45.5,1.5814327132705956,8.830169595599006,2.6780606300806443e-10,0.2153948281902413,11214.57928912786,36.31957378847691,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-265WW,SEG Solar Inc,Multi-c-Si,0,265.0,239.4,1.63,,,60.0,8.83,38.3,8.53,31.1,0.0037704100000000005,-0.10046089999999999,45.5,1.5814327132705956,8.830169595599006,2.6780606300806443e-10,0.2153948281902413,11214.57928912786,36.31957378847691,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPB-265BB,SEG Solar Inc,Multi-c-Si,0,265.0,241.7,1.64,,,60.0,9.03,37.5,8.47,31.3,0.00374745,-0.11505000000000001,47.3,1.4580614044051026,9.038794699781823,5.994222855053887e-11,0.20321315376370255,208.65007559463834,3.1109975382746153,-0.3826,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-265WB,SEG Solar Inc,Multi-c-Si,0,265.0,241.7,1.64,,,60.0,9.03,37.5,8.47,31.3,0.0037564799999999995,-0.1221,45.8,1.5070818304421258,9.037538160093165,1.3859383812529503e-10,0.19064504063984883,228.37466480279141,3.8928204180939456,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-265WW,SEG Solar Inc,Multi-c-Si,0,265.0,241.7,1.64,,,60.0,9.03,37.5,8.47,31.3,0.0037564799999999995,-0.1221,45.8,1.5070818304421258,9.037538160093165,1.3859383812529503e-10,0.19064504063984883,228.37466480279141,3.8928204180939456,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-270WB,SEG Solar Inc,Mono-c-Si,0,270.0,243.7,1.63,,,1.0,9.04,38.5,8.77,30.8,0.00318208,-0.093632,45.8,1.569191370503279,9.040201792504261,1.9981451140662085e-10,0.24800318691579223,11110.203593593826,43.4755354401686,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-270WW,SEG Solar Inc,Mono-c-Si,0,270.0,243.7,1.63,,,1.0,9.04,38.5,8.77,30.8,0.00318208,-0.093632,45.8,1.569191370503279,9.040201792504261,1.9981451140662085e-10,0.24800318691579223,11110.203593593826,43.4755354401686,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-270BB,SEG Solar Inc,Multi-c-Si,0,270.0,243.5,1.63,,,1.0,8.94,38.5,8.63,31.3,0.005363999999999999,-0.144375,45.8,1.6512858130425137,8.940001709165637,6.694043669567275e-10,0.19104081281545723,999994.3012296387,2.146948466844598,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-270BW,SEG Solar Inc,Multi-c-Si,0,270.0,243.5,1.63,,,1.0,8.94,38.5,8.63,31.3,0.005363999999999999,-0.144375,45.8,1.6512858130425137,8.940001709165637,6.694043669567275e-10,0.19104081281545723,999994.3012296387,2.146948466844598,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-270WB,SEG Solar Inc,Multi-c-Si,0,270.0,244.1,1.63,,,1.0,8.94,38.5,8.63,31.3,0.00381738,-0.10098549999999999,45.5,1.5900445146333835,8.940170485083174,2.726072532674809e-10,0.21331553725187313,11186.010530699019,36.378763533819644,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-270WW,SEG Solar Inc,Multi-c-Si,0,270.0,244.1,1.63,,,1.0,8.94,38.5,8.63,31.3,0.00381738,-0.10098549999999999,45.5,1.5900445146333835,8.940170485083174,2.726072532674809e-10,0.21331553725187313,11186.010530699019,36.378763533819644,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPB-270BB,SEG Solar Inc,Multi-c-Si,0,270.0,246.4,1.64,,,60.0,9.08,37.7,8.58,31.5,0.0037682000000000006,-0.11566360000000002,47.3,1.4610878497058004,9.0847942612162,5.5918939724898444e-11,0.19978488243158185,378.3787955527965,2.461213637395205,-0.3826,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-270WB,SEG Solar Inc,Multi-c-Si,0,270.0,246.3,1.64,,,60.0,9.08,37.7,8.58,31.5,0.00377728,-0.12275120000000002,45.8,1.510059658140772,9.083788614383009,1.2932491058773028e-10,0.18740083124804702,449.13509183815466,3.241790956283519,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-270WW,SEG Solar Inc,Multi-c-Si,0,270.0,246.3,1.64,,,60.0,9.08,37.7,8.58,31.5,0.00377728,-0.12275120000000002,45.8,1.510059658140772,9.083788614383009,1.2932491058773028e-10,0.18740083124804702,449.13509183815466,3.241790956283519,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-275WB,SEG Solar Inc,Mono-c-Si,0,275.0,248.3,1.63,,,1.0,9.12,38.7,8.85,31.1,0.0032102399999999996,-0.0941184,45.8,1.5805832367935853,9.120158025966429,2.1199313537678624e-10,0.22862236340358946,13194.310139772193,44.05744399388744,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-275WW,SEG Solar Inc,Mono-c-Si,0,275.0,248.3,1.63,,,1.0,9.12,38.7,8.85,31.1,0.0032102399999999996,-0.0941184,45.8,1.5805832367935853,9.120158025966429,2.1199313537678624e-10,0.22862236340358946,13194.310139772193,44.05744399388744,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-275BB,SEG Solar Inc,Multi-c-Si,0,275.0,248.2,1.63,,,1.0,9.02,38.8,8.71,31.6,0.005412,-0.1455,45.8,1.6658782718887368,9.020001642349012,6.919016495937043e-10,0.18194977580979166,999999.9214618579,2.346968077045384,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-275BW,SEG Solar Inc,Multi-c-Si,0,275.0,248.2,1.63,,,1.0,9.02,38.8,8.71,31.6,0.005412,-0.1455,45.8,1.6658782718887368,9.020001642349012,6.919016495937043e-10,0.18194977580979166,999999.9214618579,2.346968077045384,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-275WB,SEG Solar Inc,Multi-c-Si,0,275.0,248.7,1.63,,,1.0,9.02,38.8,8.71,31.6,0.00385154,-0.10177239999999999,45.5,1.6039275889604279,9.02016450349287,2.813167997216121e-10,0.20432999638747884,11203.79449253941,36.6266816409468,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PB-275WW,SEG Solar Inc,Multi-c-Si,0,275.0,248.7,1.63,,,1.0,9.02,38.8,8.71,31.6,0.00385154,-0.10177239999999999,45.5,1.6039275889604279,9.02016450349287,2.813167997216121e-10,0.20432999638747884,11203.79449253941,36.6266816409468,-0.4573,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPB-275BB,SEG Solar Inc,Multi-c-Si,0,275.0,251.0,1.64,,,60.0,9.14,38.0,8.65,31.8,0.0037931000000000006,-0.11658400000000001,47.3,1.4727776776241321,9.143929337283735,5.644450091239106e-11,0.19367680921114844,450.5100905054795,2.4784145838291916,-0.3826,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-275WB,SEG Solar Inc,Multi-c-Si,0,275.0,251.0,1.64,,,60.0,9.14,38.0,8.65,31.8,0.00380224,-0.123728,45.8,1.5221428275721138,9.14299026760962,1.3053925172644396e-10,0.1812846273960548,554.1114839757308,3.259192683950518,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-275WW,SEG Solar Inc,Multi-c-Si,0,275.0,251.0,1.64,,,60.0,9.14,38.0,8.65,31.8,0.00380224,-0.123728,45.8,1.5221428275721138,9.14299026760962,1.3053925172644396e-10,0.1812846273960548,554.1114839757308,3.259192683950518,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-280BB,SEG Solar Inc,Mono-c-Si,0,280.0,253.4,1.63,,,60.0,9.22,38.9,8.95,31.3,0.0053476,-0.145097,45.53,1.6558985969475208,9.220001807358377,5.786023633830124e-10,0.19590167707791065,999999.3528298741,1.2632807111228461,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-280BW,SEG Solar Inc,Mono-c-Si,0,280.0,253.4,1.63,,,1.0,9.22,38.9,8.95,31.3,0.0053476,-0.145097,45.53,1.6558985969475208,9.220001807358377,5.786023633830124e-10,0.19590167707791065,999999.3528298741,1.2632807111228461,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-280WB,SEG Solar Inc,Mono-c-Si,0,280.0,253.0,1.63,,,1.0,9.22,38.9,8.95,31.3,0.0032454400000000005,-0.0946048,45.8,1.589939545805754,9.220193809859182,2.1825737538697794e-10,0.22003601046515484,10467.671264334585,44.26902840536639,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-280WW,SEG Solar Inc,Mono-c-Si,0,280.0,253.0,1.63,,,1.0,9.22,38.9,8.95,31.3,0.0032454400000000005,-0.0946048,45.8,1.589939545805754,9.220193809859182,2.1825737538697794e-10,0.22003601046515484,10467.671264334585,44.26902840536639,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMB-280BB,SEG Solar Inc,Mono-c-Si,0,280.0,254.1,1.636,,,60.0,9.3,38.0,8.75,32.0,0.0039153,-0.113582,48.2,1.4991527818208852,9.305896841008892,8.979914464600589e-11,0.1587529423905516,250.3717498433737,9.073012965857838,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-280BB,SEG Solar Inc,Multi-c-Si,0,280.0,255.7,1.64,,,60.0,9.24,38.2,8.75,32.0,0.0038346000000000005,-0.11719760000000003,47.3,1.4808720021799637,9.243608682874134,5.7439719914400853e-11,0.18836809535084997,482.3148287446228,2.530745732332816,-0.3826,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-280WB,SEG Solar Inc,Multi-c-Si,0,280.0,255.7,1.64,,,60.0,9.24,38.2,8.75,32.0,0.0038438400000000003,-0.12437920000000002,45.8,1.5305190101967385,9.242694760220951,1.3283800535878614e-10,0.17604022105671807,603.6202337477877,3.311741479670996,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-280WW,SEG Solar Inc,Multi-c-Si,0,280.0,255.7,1.64,,,60.0,9.24,38.2,8.75,32.0,0.0038438400000000003,-0.12437920000000002,45.8,1.5305190101967385,9.242694760220951,1.3283800535878614e-10,0.17604022105671807,603.6202337477877,3.311741479670996,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-285BB,SEG Solar Inc,Mono-c-Si,0,285.0,258.0,1.63,,,60.0,9.33,39.1,9.05,31.5,0.005411400000000001,-0.145843,45.53,1.6652390383696214,9.330138112450557,5.921956560734161e-10,0.19308824021097612,13043.407617435007,1.3572968498149476,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-285BW,SEG Solar Inc,Mono-c-Si,0,285.0,258.0,1.63,,,1.0,9.33,39.1,9.05,31.5,0.005411400000000001,-0.145843,45.53,1.6652390383696214,9.330138112450557,5.921956560734161e-10,0.19308824021097612,13043.407617435007,1.3572968498149476,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-285WB,SEG Solar Inc,Mono-c-Si,0,285.0,257.6,1.63,,,1.0,9.33,39.1,9.05,31.5,0.0032841600000000004,-0.0950912,45.8,1.5984890597013144,9.330191415374562,2.2213478521532577e-10,0.2186789584675624,10658.917952430063,44.33570806588976,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-285WW,SEG Solar Inc,Mono-c-Si,0,285.0,257.6,1.63,,,1.0,9.33,39.1,9.05,31.5,0.0032841600000000004,-0.0950912,45.8,1.5984890597013144,9.330191415374562,2.2213478521532577e-10,0.2186789584675624,10658.917952430063,44.33570806588976,-0.4578,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMB-285BB,SEG Solar Inc,Mono-c-Si,0,285.0,258.7,1.636,,,60.0,9.39,38.3,8.86,32.2,0.0039531900000000005,-0.1144787,48.2,1.5074061595290817,9.394855569906063,8.567081125109495e-11,0.16590623171476598,320.8396790597514,8.563777760574688,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-285WB,SEG Solar Inc,Multi-c-Si,0,285.0,260.4,1.64,,,60.0,9.32,38.5,8.83,32.3,0.00387712,-0.125356,45.8,1.543427971618656,9.322450304927333,1.359855517485066e-10,0.16957928693519,645.0131923914132,3.4333813778918736,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPB-285WW,SEG Solar Inc,Multi-c-Si,0,285.0,260.4,1.64,,,60.0,9.32,38.5,8.83,32.3,0.00387712,-0.125356,45.8,1.543427971618656,9.322450304927333,1.359855517485066e-10,0.16957928693519,645.0131923914132,3.4333813778918736,-0.4103,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E11B-285,SEG Solar Inc,Multi-c-Si,0,285.0,259.7,1.7,,,340.0,8.36,43.25,8.1,35.2,0.00836,-0.12975,44.8,1.846223994765501,8.360001695942206,5.601930004938751e-10,0.20276296335938107,999999.5032327602,26.33298527834503,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-290BB,SEG Solar Inc,Mono-c-Si,0,290.0,268.7,1.575,,,60.0,9.44,39.3,9.15,31.7,0.0040592,-0.108075,45.16,1.4717551507068625,9.440002767265073,2.3882873718906722e-11,0.2703780113877456,922380.1633388927,6.402204285967757,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-290BW,SEG Solar Inc,Mono-c-Si,0,290.0,262.7,1.63,,,1.0,9.44,39.3,9.15,31.7,0.0054752,-0.146589,45.53,1.6736900323742763,9.440001827950399,5.987970518661384e-10,0.19351318023463945,999999.4026101115,1.35120474156979,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-290WB,SEG Solar Inc,Mono-c-Si,0,290.0,270.4,1.575,,,60.0,9.44,39.3,9.15,31.7,0.0035872,-0.10689599999999999,43.47,1.4669103575179006,9.440002784711567,2.186680502386681e-11,0.2722221897391257,922850.6368432142,6.883441246557068,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-290WW,SEG Solar Inc,Mono-c-Si,0,290.0,270.4,1.575,,,60.0,9.44,39.3,9.15,31.7,0.0035872,-0.10689599999999999,43.47,1.4669103575179006,9.440002784711567,2.186680502386681e-11,0.2722221897391257,922850.6368432142,6.883441246557068,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-290WB,SEG Solar Inc,Multi-c-Si,0,290.0,261.6,1.94,,,1.0,8.65,44.3,8.11,35.8,0.0041174,-0.1374186,45.6,1.8318957944508787,8.658397901770646,2.68781222897104e-10,0.3829843468321338,394.4812909292734,15.356192001025846,-0.4522,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PA-290WW,SEG Solar Inc,Multi-c-Si,0,290.0,261.6,1.94,,,1.0,8.65,44.3,8.11,35.8,0.0041174,-0.1374186,45.6,1.8318957944508787,8.658397901770646,2.68781222897104e-10,0.3829843468321338,394.4812909292734,15.356192001025846,-0.4522,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-290BB,SEG Solar Inc,Mono-c-Si,0,290.0,263.4,1.636,,,60.0,9.46,38.6,8.93,32.5,0.003982660000000001,-0.1153754,48.2,1.520065035339955,9.464559146728613,8.75800317324495e-11,0.15985440503124548,331.68985582545054,8.69020399360754,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-290WB,SEG Solar Inc,Mono-c-Si,0,290.0,265.3,1.6368,,,60.0,9.46,38.6,8.93,32.5,0.003585340000000001,-0.1142174,46.5,1.5144297779450635,9.464669210929577,7.966916158819152e-11,0.1612351470954174,326.6685869957143,9.018289350055992,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-290WW,SEG Solar Inc,Mono-c-Si,0,290.0,265.3,1.6368,,,60.0,9.46,38.6,8.93,32.5,0.003585340000000001,-0.1142174,46.5,1.5144297779450635,9.464669210929577,7.966916158819152e-11,0.1612351470954174,326.6685869957143,9.018289350055992,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E11B-290,SEG Solar Inc,Multi-c-Si,0,290.0,264.4,1.7,,,340.0,8.47,43.5,8.21,35.35,0.008470000000000002,-0.1305,44.8,1.856007800971642,8.47000173836684,5.612380820004214e-10,0.20513528502248252,999999.4949308389,26.21744006463582,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-295BB,SEG Solar Inc,Mono-c-Si,0,295.0,273.4,1.575,,,60.0,9.56,39.5,9.25,31.9,0.0041107999999999995,-0.10862500000000001,45.16,1.4788833029842339,9.560002842858378,2.4029027760562892e-11,0.27341507428797074,919481.1413304432,6.346031964119889,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-295BW,SEG Solar Inc,Mono-c-Si,0,295.0,267.4,1.63,,,1.0,9.56,39.5,9.25,31.9,0.005544800000000001,-0.147335,45.53,1.6822377917608178,9.56017130855244,6.064495904177559e-10,0.19640635647014656,10960.680929734503,1.3527875611718805,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-295WB,SEG Solar Inc,Mono-c-Si,0,295.0,275.2,1.575,,,60.0,9.56,39.5,9.25,31.9,0.0036328000000000003,-0.10744000000000001,43.47,1.4740301464694558,9.560002860133,2.200618773961522e-11,0.275214097210219,919938.484599389,6.829226927571534,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-295WW,SEG Solar Inc,Mono-c-Si,0,295.0,275.2,1.575,,,60.0,9.56,39.5,9.25,31.9,0.0036328000000000003,-0.10744000000000001,43.47,1.4740301464694558,9.560002860133,2.200618773961522e-11,0.275214097210219,919938.484599389,6.829226927571534,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-295WB,SEG Solar Inc,Multi-c-Si,0,295.0,266.2,1.94,,,1.0,8.78,44.4,8.22,35.9,0.00417928,-0.13772879999999998,45.6,1.8379645228970163,8.789695432136687,2.7935116910783645e-10,0.3753315454275389,339.8931903377696,15.582463958374518,-0.4522,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6PA-295WW,SEG Solar Inc,Multi-c-Si,0,295.0,266.2,1.94,,,1.0,8.78,44.4,8.22,35.9,0.00417928,-0.13772879999999998,45.6,1.8379645228970163,8.789695432136687,2.7935116910783645e-10,0.3753315454275389,339.8931903377696,15.582463958374518,-0.4522,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-295BB,SEG Solar Inc,Mono-c-Si,0,295.0,268.1,1.636,,,60.0,9.55,38.9,9.03,32.7,0.00402055,-0.1162721,48.2,1.5292365303785043,9.55395927148837,8.479741581437002e-11,0.1666339911523293,401.93118420437935,8.317892358191415,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-295WB,SEG Solar Inc,Mono-c-Si,0,295.0,270.0,1.6368,,,60.0,9.55,38.9,9.03,32.7,0.003619450000000001,-0.1151051,46.5,1.52357689037442,9.554066693562133,7.713764942719624e-11,0.16800328108966314,394.529700025396,8.644932900158825,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-295WW,SEG Solar Inc,Mono-c-Si,0,295.0,270.0,1.6368,,,60.0,9.55,38.9,9.03,32.7,0.003619450000000001,-0.1151051,46.5,1.52357689037442,9.554066693562133,7.713764942719624e-11,0.16800328108966314,394.529700025396,8.644932900158825,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E11B-295,SEG Solar Inc,Multi-c-Si,0,295.0,269.1,1.7,,,340.0,8.57,43.7,8.3,35.55,0.00857,-0.13110000000000002,44.8,1.8646712057154577,8.570001758748806,5.687931899211337e-10,0.20511745352331154,999999.5124267323,26.234282665961405,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-300-BMB-BG,SEG Solar Inc,Mono-c-Si,1,300.0,277.9,1.72,,,60.0,9.54,39.6,9.04,33.2,0.00292878,-0.1181664,44.0,1.5195705855490043,9.543648199231374,4.55357341678013e-11,0.1895644574453094,495.7089404794986,3.3506246733018408,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-300BB,SEG Solar Inc,Mono-c-Si,0,300.0,278.2,1.575,,,60.0,9.65,39.7,9.35,32.1,0.0041494999999999995,-0.10917500000000001,45.16,1.4880337969566284,9.650002513910392,2.4989946931823823e-11,0.26042616667936996,999726.4149505083,6.602922226504449,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-300BW,SEG Solar Inc,Mono-c-Si,0,300.0,272.0,1.63,,,1.0,9.65,39.7,9.35,32.1,0.005597,-0.14808100000000002,45.53,1.6923997210059463,9.650001782160425,6.265069344779014e-10,0.18455868397789468,999999.4476501214,1.5419423907777234,-0.457,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-300WB,SEG Solar Inc,Mono-c-Si,0,300.0,279.9,1.575,,,60.0,9.65,39.7,9.35,32.1,0.003667,-0.10798400000000001,43.47,1.4831325133452935,9.650002748405752,2.288097963643245e-11,0.2622442930101577,920807.153673455,7.085176955302632,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-300WW,SEG Solar Inc,Mono-c-Si,0,300.0,279.9,1.575,,,60.0,9.65,39.7,9.35,32.1,0.003667,-0.10798400000000001,43.47,1.4831325133452935,9.650002748405752,2.288097963643245e-11,0.2622442930101577,920807.153673455,7.085176955302632,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-300WB,SEG Solar Inc,Multi-c-Si,0,300.0,270.8,1.94,,,1.0,8.68,44.7,8.38,35.8,0.00413168,-0.13865940000000002,45.6,1.8480074963492799,8.680234923655325,2.713521767895728e-10,0.31782828836348603,11743.221326118728,15.37227265834578,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-300WW,SEG Solar Inc,Multi-c-Si,0,300.0,270.8,1.94,,,1.0,8.68,44.7,8.38,35.8,0.00413168,-0.13865940000000002,45.6,1.8480074963492799,8.680234923655325,2.713521767895728e-10,0.31782828836348603,11743.221326118728,15.37227265834578,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMB-300BB,SEG Solar Inc,Mono-c-Si,0,300.0,272.8,1.636,,,60.0,9.62,39.2,9.1,33.0,0.00405002,-0.1171688,48.2,1.5418933198855427,9.623700071964791,8.66747948371135e-11,0.16069080328329652,417.78797937048853,8.443947981143666,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-300WB,SEG Solar Inc,Mono-c-Si,0,300.0,274.7,1.6368,,,60.0,9.62,39.2,9.1,33.0,0.00364598,-0.11599280000000001,46.5,1.5361828825815613,9.623804215696493,7.884444732617212e-11,0.16206304357394524,409.8207497863423,8.771154291616234,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-300WW,SEG Solar Inc,Mono-c-Si,0,300.0,274.7,1.6368,,,60.0,9.62,39.2,9.1,33.0,0.00364598,-0.11599280000000001,46.5,1.5361828825815613,9.623804215696493,7.884444732617212e-11,0.16206304357394524,409.8207497863423,8.771154291616234,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-300,SEG Solar Inc,Mono-c-Si,0,300.0,274.4,1.7,,,340.0,8.73,43.85,8.43,35.6,0.00873,-0.13155,44.4,1.8633117426030277,8.730002040170794,5.255336380101006e-10,0.23357677606444563,999999.4746127952,25.23270512638211,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11B-300,SEG Solar Inc,Multi-c-Si,0,300.0,273.8,1.7,,,340.0,8.67,43.95,8.4,35.75,0.00867,-0.13185000000000002,44.8,1.8756001212720854,8.670001748229922,5.773132161399367e-10,0.20153872133501474,999999.5179332481,26.2679549636139,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-305-BMB-BG,SEG Solar Inc,Mono-c-Si,1,305.0,282.6,1.72,,,60.0,9.61,39.9,9.11,33.5,0.00295027,-0.1190616,44.0,1.5319366975553022,9.613403930410623,4.655685720840516e-11,0.18352873761212857,518.13962288466,3.4730573920408014,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MB-305BB,SEG Solar Inc,Mono-c-Si,0,305.0,283.0,1.575,,,60.0,9.76,39.9,9.45,32.3,0.0041968,-0.10972500000000002,45.16,1.4958408517762132,9.760002520564942,2.5415241374921675e-11,0.25819937073745186,999830.383396577,6.650686166633076,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-305WB,SEG Solar Inc,Mono-c-Si,0,305.0,284.7,1.575,,,60.0,9.76,39.9,9.45,32.3,0.0037088,-0.10852800000000001,43.47,1.4909172967941398,9.760002538094783,2.3272254622322144e-11,0.2599966379838134,999833.2375627714,7.133828278633057,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-305WW,SEG Solar Inc,Mono-c-Si,0,305.0,284.7,1.575,,,60.0,9.76,39.9,9.45,32.3,0.0037088,-0.10852800000000001,43.47,1.4909172967941398,9.760002538094783,2.3272254622322144e-11,0.2599966379838134,999833.2375627714,7.133828278633057,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-305BB,SEG Solar Inc,Multi-c-Si,0,305.0,276.2,1.94,,,1.0,8.73,45.0,8.43,36.2,0.0050634,-0.1593,45.74,1.8677273382019204,8.730002594190227,3.0016402581116915e-10,0.2970539045788328,999997.5370429445,1.6705278694690442,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-305BW,SEG Solar Inc,Multi-c-Si,0,305.0,276.2,1.94,,,1.0,8.73,45.0,8.43,36.2,0.0050634,-0.1593,45.74,1.8677273382019204,8.730002594190227,3.0016402581116915e-10,0.2970539045788328,999997.5370429445,1.6705278694690442,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-305WB,SEG Solar Inc,Multi-c-Si,0,305.0,275.5,1.94,,,1.0,8.73,45.0,8.43,36.2,0.0041554800000000005,-0.13959,45.6,1.8644029262156112,8.730219599017891,2.8742452977936957e-10,0.29622781444858626,11776.368383525381,15.85503712145529,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-305WW,SEG Solar Inc,Multi-c-Si,0,305.0,275.5,1.94,,,1.0,8.73,45.0,8.43,36.2,0.0041554800000000005,-0.13959,45.6,1.8644029262156112,8.730219599017891,2.8742452977936957e-10,0.29622781444858626,11776.368383525381,15.85503712145529,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMB-305BB,SEG Solar Inc,Mono-c-Si,0,305.0,277.5,1.636,,,60.0,9.69,39.5,9.19,33.2,0.00407949,-0.1180655,48.2,1.550309263860138,9.692573828608463,8.285761278467368e-11,0.16784221982893535,631.8956910666801,7.976946713976085,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-305WB,SEG Solar Inc,Mono-c-Si,0,305.0,279.4,1.6368,,,60.0,9.69,39.5,9.19,33.2,0.0036725100000000004,-0.1168805,46.5,1.5445798775016464,9.692671456656436,7.537170960076735e-11,0.1692032250762884,613.7398226087022,8.302790298050938,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-305WW,SEG Solar Inc,Mono-c-Si,0,305.0,279.4,1.6368,,,60.0,9.69,39.5,9.19,33.2,0.0036725100000000004,-0.1168805,46.5,1.5445798775016464,9.692671456656436,7.537170960076735e-11,0.1692032250762884,613.7398226087022,8.302790298050938,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-305,SEG Solar Inc,Mono-c-Si,0,305.0,279.1,1.7,,,340.0,8.83,44.1,8.52,35.8,0.008830000000000001,-0.1323,44.4,1.8731754412232986,8.830002100697275,5.265055198826755e-10,0.23778114469042122,999999.4810001352,25.135236614949083,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11B-305,SEG Solar Inc,Multi-c-Si,0,305.0,278.5,1.7,,,340.0,8.76,44.2,8.49,35.95,0.00876,-0.13260000000000002,44.8,1.886492391727877,8.760001740146885,5.849264358973986e-10,0.19854569143633796,999999.52429301,26.29655378129442,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-310-BMB-BG,SEG Solar Inc,Mono-c-Si,1,310.0,287.4,1.72,,,60.0,9.68,40.2,9.18,33.8,0.00297176,-0.1199568,44.0,1.544300882703115,9.68316994649573,4.758553380525605e-11,0.17758696800822854,542.2935894369749,3.5933965426655985,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-310WB,SEG Solar Inc,Mono-c-Si,0,310.0,281.4,1.63,,,1.0,8.81,45.2,8.52,36.4,0.004149510000000001,-0.12882,45.7,1.867302772398636,8.810210567010861,2.7055115769949177e-10,0.2824347815275414,11816.947451333413,25.470745097801334,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-310WW,SEG Solar Inc,Mono-c-Si,0,310.0,281.4,1.63,,,1.0,8.81,45.2,8.52,36.4,0.004149510000000001,-0.12882,45.7,1.867302772398636,8.810210567010861,2.7055115769949177e-10,0.2824347815275414,11816.947451333413,25.470745097801334,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-310BB,SEG Solar Inc,Mono-c-Si,0,310.0,287.7,1.575,,,60.0,9.82,40.2,9.51,32.6,0.0042226,-0.11055000000000001,45.16,1.5083596214282178,9.82000246617531,2.6153138167160865e-11,0.251057184760418,999721.8358365378,6.844771926355853,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-310WB,SEG Solar Inc,Mono-c-Si,0,310.0,289.5,1.575,,,60.0,9.82,40.2,9.51,32.6,0.0037316000000000003,-0.10934400000000001,43.47,1.5033872435627138,9.820002483903176,2.3946466933518093e-11,0.2528640273723944,999727.1848251441,7.328163467465625,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-310WW,SEG Solar Inc,Mono-c-Si,0,310.0,289.5,1.575,,,60.0,9.82,40.2,9.51,32.6,0.0037316000000000003,-0.10934400000000001,43.47,1.5033872435627138,9.820002483903176,2.3946466933518093e-11,0.2528640273723944,999727.1848251441,7.328163467465625,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-310BB,SEG Solar Inc,Multi-c-Si,0,310.0,280.9,1.94,,,1.0,8.8,45.2,8.5,36.5,0.005104000000000001,-0.16000799999999998,45.74,1.879728160888812,8.800002432434235,3.1726514496819435e-10,0.2763173306265578,999999.0811322803,2.060586114859567,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-310BW,SEG Solar Inc,Multi-c-Si,0,310.0,280.9,1.94,,,1.0,8.8,45.2,8.5,36.5,0.005104000000000001,-0.16000799999999998,45.74,1.879728160888812,8.800002432434235,3.1726514496819435e-10,0.2763173306265578,999999.0811322803,2.060586114859567,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-310WB,SEG Solar Inc,Multi-c-Si,0,310.0,280.1,1.94,,,1.0,8.8,45.2,8.5,36.5,0.0041888,-0.14021039999999999,45.6,1.876155988824672,8.80017417474055,3.0296300591418027e-10,0.27590951524018664,13940.085914117539,16.27274770849368,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-310WW,SEG Solar Inc,Multi-c-Si,0,310.0,280.1,1.94,,,1.0,8.8,45.2,8.5,36.5,0.0041888,-0.14021039999999999,45.6,1.876155988824672,8.80017417474055,3.0296300591418027e-10,0.27590951524018664,13940.085914117539,16.27274770849368,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMB-310BB,SEG Solar Inc,Mono-c-Si,0,310.0,282.2,1.636,,,60.0,9.77,39.8,9.26,33.5,0.004113169999999999,-0.11896219999999999,48.2,1.5637853440326677,9.772851973380849,8.581418418126436e-11,0.16164348380768467,553.741741397714,8.213655849526484,-0.3935,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-310WB,SEG Solar Inc,Mono-c-Si,0,310.0,284.1,1.6368,,,60.0,9.77,39.8,9.26,33.5,0.0037028300000000003,-0.11776819999999999,46.5,1.5579994063721412,9.772950389292381,7.806059956776514e-11,0.16300910903111762,539.7928586215859,8.540056810340902,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BMB-310WW,SEG Solar Inc,Mono-c-Si,0,310.0,284.1,1.6368,,,60.0,9.77,39.8,9.26,33.5,0.0037028300000000003,-0.11776819999999999,46.5,1.5579994063721412,9.772950389292381,7.806059956776514e-11,0.16300910903111762,539.7928586215859,8.540056810340902,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPA-310WW,SEG Solar Inc,Multi-c-Si,0,310.0,282.7,1.954,,,72.0,8.84,45.0,8.32,37.3,0.0044995600000000005,-0.15007500000000001,44.9,1.8479611304010504,8.845337167523022,2.3224135201809964e-10,0.258080471450516,427.4611204728647,5.767015871043611,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-310,SEG Solar Inc,Mono-c-Si,0,310.0,283.8,1.7,,,340.0,8.92,44.35,8.62,36.0,0.00892,-0.13305,44.4,1.8851029258057486,8.920002024088781,5.406355917464432e-10,0.22679900345522208,999999.487743693,25.302220576173756,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11B-310,SEG Solar Inc,Multi-c-Si,0,310.0,283.2,1.7,,,340.0,8.86,44.45,8.58,36.15,0.00886,-0.13335000000000002,44.8,1.8963416216818885,8.860001806833395,5.856331919278376e-10,0.20382621844843432,999999.5291701464,26.192014120982012,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-315-6MB-HV,SEG Solar Inc,Mono-c-Si,0,315.0,291.5,1.67,,,60.0,9.89,40.9,9.61,32.8,0.0032538099999999998,-0.1251131,44.2,1.5705958433536567,9.890192816370039,4.848143604240227e-11,0.2589179404595233,13280.51675654464,0.9673988052194915,-0.3951,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-315-BMB-BG,SEG Solar Inc,Mono-c-Si,1,315.0,292.1,1.72,,,60.0,9.75,40.5,9.24,34.1,0.0029932500000000003,-0.120852,44.0,1.5575190253593028,9.75347297472844,4.9259034503821014e-11,0.1715530747894482,481.61667034622815,3.82502292116001,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-315WB,SEG Solar Inc,Mono-c-Si,0,315.0,286.1,1.63,,,1.0,8.87,45.5,8.59,36.7,0.00417777,-0.12967499999999998,45.7,1.8822248092242275,8.870198323148372,2.8139651017760374e-10,0.2649109510345781,11848.180091145192,25.800107312444418,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-315WW,SEG Solar Inc,Mono-c-Si,0,315.0,286.1,1.63,,,1.0,8.87,45.5,8.59,36.7,0.00417777,-0.12967499999999998,45.7,1.8822248092242275,8.870198323148372,2.8139651017760374e-10,0.2649109510345781,11848.180091145192,25.800107312444418,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-315BB,SEG Solar Inc,Mono-c-Si,0,315.0,292.5,1.575,,,60.0,9.92,40.4,9.61,32.8,0.0042656,-0.1111,45.16,1.5168356615707492,9.920002419259758,2.687443096444622e-11,0.24379748654083733,999717.5295724416,6.992331913643515,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-315WB,SEG Solar Inc,Mono-c-Si,0,315.0,294.3,1.575,,,60.0,9.92,40.4,9.61,32.8,0.0037695999999999997,-0.109888,43.47,1.5118282382424346,9.920002437159452,2.4605200574222504e-11,0.24560340928886096,999722.9888661471,7.47571518281666,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-315WW,SEG Solar Inc,Mono-c-Si,0,315.0,294.3,1.575,,,60.0,9.92,40.4,9.61,32.8,0.0037695999999999997,-0.109888,43.47,1.5118282382424346,9.920002437159452,2.4605200574222504e-11,0.24560340928886096,999722.9888661471,7.47571518281666,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-315BB,SEG Solar Inc,Multi-c-Si,0,315.0,285.5,1.94,,,1.0,8.87,45.3,8.56,36.8,0.005144599999999999,-0.16036199999999998,45.74,1.8884717313679502,8.870002245354057,3.390136900130169e-10,0.25305138504443875,999993.5379801338,2.542901760054362,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-315BW,SEG Solar Inc,Multi-c-Si,0,315.0,285.5,1.94,,,1.0,8.87,45.3,8.56,36.8,0.005144599999999999,-0.16036199999999998,45.74,1.8884717313679502,8.870002245354057,3.390136900130169e-10,0.25305138504443875,999993.5379801338,2.542901760054362,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-315WB,SEG Solar Inc,Multi-c-Si,0,315.0,284.8,1.94,,,1.0,8.87,45.3,8.56,36.8,0.004222119999999999,-0.14052059999999997,45.6,1.8847626545449245,8.870160699132933,3.2327111256331887e-10,0.25272861739266583,13949.628385936496,16.807987642821285,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-315WW,SEG Solar Inc,Multi-c-Si,0,315.0,284.8,1.94,,,1.0,8.87,45.3,8.56,36.8,0.004222119999999999,-0.14052059999999997,45.6,1.8847626545449245,8.870160699132933,3.2327111256331887e-10,0.25272861739266583,13949.628385936496,16.807987642821285,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPA-315WW,SEG Solar Inc,Multi-c-Si,0,315.0,287.4,1.954,,,72.0,8.91,45.2,8.4,37.5,0.00453519,-0.15074200000000001,44.9,1.8554592629698838,8.914402732438745,2.3233526767733885e-10,0.2527505012597052,511.50218151215665,5.697213149220086,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-315,SEG Solar Inc,Mono-c-Si,0,315.0,288.5,1.7,,,340.0,9.02,44.6,8.71,36.2,0.00902,-0.1338,44.4,1.894967722483559,9.020002085273902,5.415523810970023e-10,0.2310629295581094,999999.4929844575,25.205593611748967,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11B-315,SEG Solar Inc,Multi-c-Si,0,315.0,287.9,1.7,,,340.0,8.96,44.7,8.66,36.4,0.008960000000000001,-0.13410000000000002,44.8,1.9063245724687443,8.960001888681884,5.872928174797581e-10,0.21067938789295187,999999.5470506846,26.105577068300548,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-320-6MB-HV,SEG Solar Inc,Mono-c-Si,0,320.0,296.2,1.67,,,60.0,9.98,41.1,9.7,33.0,0.00328342,-0.1257249,44.2,1.578942216552499,9.980002757413697,4.9477353384979864e-11,0.25333785821755966,916318.8441934716,1.0580070288598558,-0.3951,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-320-BMB-BG,SEG Solar Inc,Mono-c-Si,1,320.0,296.9,1.72,,,60.0,9.84,40.7,9.33,34.3,0.00302088,-0.12144880000000001,44.0,1.5655677016119036,9.843215301729257,5.0034911873971226e-11,0.1670029002676911,511.0900078707057,3.8769537610884166,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-320-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,320.0,296.7,1.69,,,60.0,9.93,40.4,9.42,34.0,0.0033762,-0.12136159999999999,44.1,1.5643577448368606,9.932851490599369,6.001357254276534e-11,0.16736249400711836,582.8213608967613,4.5793907937241825,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-320WB,SEG Solar Inc,Mono-c-Si,0,320.0,290.8,1.63,,,1.0,8.99,45.6,8.68,36.9,0.004234290000000001,-0.12996,45.7,1.8866002889797422,8.990204574105302,2.860780748867104e-10,0.2683097269337019,11790.901597993023,25.831151919517687,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-320WW,SEG Solar Inc,Mono-c-Si,0,320.0,290.8,1.63,,,1.0,8.99,45.6,8.68,36.9,0.004234290000000001,-0.12996,45.7,1.8866002889797422,8.990204574105302,2.860780748867104e-10,0.2683097269337019,11790.901597993023,25.831151919517687,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-320WB,SEG Solar Inc,Mono-c-Si,0,320.0,299.1,1.575,,,60.0,10.02,40.6,9.7,33.0,0.0038076,-0.11043200000000002,43.47,1.5195947570843316,10.020002444918426,2.4976889309773745e-11,0.2439524416398645,999830.1799828878,7.518813617213056,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MB-320WW,SEG Solar Inc,Mono-c-Si,0,320.0,299.1,1.575,,,60.0,10.02,40.6,9.7,33.0,0.0038076,-0.11043200000000002,43.47,1.5195947570843316,10.020002444918426,2.4976889309773745e-11,0.2439524416398645,999830.1799828878,7.518813617213056,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-320BB,SEG Solar Inc,Multi-c-Si,0,320.0,290.2,1.94,,,1.0,8.96,45.5,8.65,37.0,0.005196800000000001,-0.16107,45.74,1.8980753953464717,8.960002191294652,3.479768690558171e-10,0.24447933792332188,999998.0565998787,2.6755029727461745,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-320BW,SEG Solar Inc,Multi-c-Si,0,320.0,290.2,1.94,,,1.0,8.96,45.5,8.65,37.0,0.005196800000000001,-0.16107,45.74,1.8980753953464717,8.960002191294652,3.479768690558171e-10,0.24447933792332188,999998.0565998787,2.6755029727461745,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-320WB,SEG Solar Inc,Multi-c-Si,0,320.0,289.4,1.94,,,1.0,8.96,45.5,8.65,37.0,0.004264960000000001,-0.141141,45.6,1.8942946480353378,8.960156971704242,3.3160678578470396e-10,0.24417111919537446,13937.399174707596,16.95279204802496,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-320WW,SEG Solar Inc,Multi-c-Si,0,320.0,289.4,1.94,,,72.0,8.96,45.5,8.65,37.0,0.004264960000000001,-0.141141,45.6,1.8942946480353378,8.960156971704242,3.3160678578470396e-10,0.24417111919537446,13937.399174707596,16.95279204802496,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPA-320WW,SEG Solar Inc,Multi-c-Si,0,320.0,292.1,1.954,,,72.0,8.97,45.5,8.47,37.8,0.0045657300000000005,-0.1517425,44.9,1.8676140415804792,8.97351859986669,2.338184399036398e-10,0.24598258398133932,627.0858204780133,5.688706328813225,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-320,SEG Solar Inc,Mono-c-Si,0,320.0,293.3,1.7,,,340.0,9.11,44.85,8.8,36.4,0.00911,-0.13455,44.4,1.9058418473736949,9.110002078766179,5.486614484732825e-10,0.22806603304481157,999999.4988215098,25.23740598686793,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-325-6MB-HV,SEG Solar Inc,Mono-c-Si,0,325.0,301.0,1.67,,,60.0,10.07,41.3,9.79,33.2,0.0033130300000000002,-0.1263367,44.2,1.5876443453987705,10.070002706614043,5.076437775396176e-11,0.24637631023298107,916053.6679159197,1.193861100185465,-0.3951,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-325-BMB-BG,SEG Solar Inc,Mono-c-Si,1,325.0,301.6,1.72,,,60.0,9.93,40.9,9.43,34.5,0.00304851,-0.12204559999999999,44.0,1.5727703007618137,9.932464624491987,5.017216266642415e-11,0.16272615239200452,655.6255354269944,3.817405677131919,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-325-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,325.0,301.4,1.69,,,60.0,10.02,40.6,9.51,34.2,0.0034068,-0.12196240000000001,44.1,1.5724826951834407,10.022607842024469,6.096671234431768e-11,0.16291659146494436,625.9674860535765,4.634292845049433,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-325WB,SEG Solar Inc,Mono-c-Si,0,325.0,295.5,1.63,,,1.0,9.04,45.9,8.77,37.1,0.00425784,-0.130815,45.7,1.9019577196701574,9.040154745407806,2.9866021543293833e-10,0.23993075561418553,14016.217380559092,26.21190704125754,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-325WW,SEG Solar Inc,Mono-c-Si,0,325.0,295.5,1.63,,,1.0,9.04,45.9,8.77,37.1,0.00425784,-0.130815,45.7,1.9019577196701574,9.040154745407806,2.9866021543293833e-10,0.23993075561418553,14016.217380559092,26.21190704125754,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-325BB,SEG Solar Inc,Multi-c-Si,0,325.0,294.8,1.94,,,1.0,9.03,45.7,8.72,37.3,0.0052374,-0.161778,45.74,1.9100676667316536,9.030002029896362,3.671295240545597e-10,0.22471756482336247,999999.198197252,3.0560307022767303,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-325BW,SEG Solar Inc,Multi-c-Si,0,325.0,294.8,1.94,,,1.0,9.03,45.7,8.72,37.3,0.0052374,-0.161778,45.74,1.9100676667316536,9.030002029896362,3.671295240545597e-10,0.22471756482336247,999999.198197252,3.0560307022767303,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-325WB,SEG Solar Inc,Multi-c-Si,0,325.0,294.1,1.94,,,1.0,9.03,45.7,8.72,37.3,0.00429828,-0.14176139999999998,45.6,1.9061385756903424,9.030145215678052,3.4934326548431344e-10,0.22444872068470995,13956.590155989385,17.371613459158933,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-325WW,SEG Solar Inc,Multi-c-Si,0,325.0,294.1,1.94,,,1.0,9.03,45.7,8.72,37.3,0.00429828,-0.14176139999999998,45.6,1.9061385756903424,9.030145215678052,3.4934326548431344e-10,0.22444872068470995,13956.590155989385,17.371613459158933,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPA-325WW,SEG Solar Inc,Multi-c-Si,0,325.0,296.8,1.954,,,72.0,9.06,45.7,8.56,38.0,0.00461154,-0.1524095,44.9,1.8761771135462457,9.063214383719345,2.3739485341623736e-10,0.24010591648948001,676.7580169203142,5.731066641308913,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-325,SEG Solar Inc,Mono-c-Si,0,325.0,298.0,1.7,,,340.0,9.21,45.1,8.88,36.6,0.009210000000000001,-0.1353,44.4,1.914688678967835,9.21000220606719,5.427035283862468e-10,0.23940195966565178,999999.5042412913,25.01447294342678,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-330-6MB-HV,SEG Solar Inc,Mono-c-Si,0,330.0,305.7,1.67,,,60.0,10.14,41.6,9.86,33.5,0.00333606,-0.12725440000000002,44.2,1.6005688507507523,10.140002639290591,5.2286877994166265e-11,0.23880636786383944,916878.5073606055,1.378156112507359,-0.3951,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-330-BMB-BG,SEG Solar Inc,Mono-c-Si,1,330.0,306.4,1.72,,,60.0,10.02,41.1,9.52,34.7,0.00307614,-0.12264240000000001,44.0,1.5808273672754392,10.02223784549633,5.095703963319195e-11,0.1583477438954367,709.0053618275607,3.8699351854458337,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-330-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,330.0,305.7,1.82,,,60.0,10.11,40.8,9.6,34.4,0.00536841,-0.11566799999999998,45.69,1.552068135567313,10.112850204634242,3.84904332080687e-11,0.16510925746891247,585.6613298268317,6.551113296583614,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-330-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,330.0,306.2,1.69,,,60.0,10.11,40.8,9.6,34.4,0.0034374,-0.1225632,44.1,1.580609942267198,10.112373646885175,6.192775838801082e-11,0.15855358206642625,675.322348148608,4.688948548221664,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-330WB,SEG Solar Inc,Mono-c-Si,0,330.0,300.2,1.63,,,1.0,9.14,46.1,8.85,37.3,0.004304940000000001,-0.131385,45.7,1.9096018920960776,9.140191718427456,2.995009307352843e-10,0.24754152492861844,11801.35656114806,26.128827551697153,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-330WW,SEG Solar Inc,Mono-c-Si,0,330.0,300.2,1.63,,,1.0,9.14,46.1,8.85,37.3,0.004304940000000001,-0.131385,45.7,1.9096018920960776,9.140191718427456,2.995009307352843e-10,0.24754152492861844,11801.35656114806,26.128827551697153,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-330BB,SEG Solar Inc,Multi-c-Si,0,330.0,299.5,1.94,,,1.0,9.12,45.9,8.8,37.5,0.005289599999999999,-0.162486,45.74,1.918588383772249,9.120002045141375,3.7153642330422953e-10,0.22417019854847736,999998.9011466686,3.0728050757999856,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-330BW,SEG Solar Inc,Multi-c-Si,0,330.0,299.5,1.94,,,1.0,9.12,45.9,8.8,37.5,0.005289599999999999,-0.162486,45.74,1.918588383772249,9.120002045141375,3.7153642330422953e-10,0.22417019854847736,999998.9011466686,3.0728050757999856,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-330WB,SEG Solar Inc,Multi-c-Si,0,330.0,298.7,1.94,,,1.0,9.12,45.9,8.8,37.5,0.0043411199999999995,-0.1423818,45.6,1.914657870190251,9.120146623903873,3.5360986807372685e-10,0.2239312454438576,13928.577020859337,17.39264365003314,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-330WW,SEG Solar Inc,Multi-c-Si,0,330.0,298.7,1.94,,,1.0,9.12,45.9,8.8,37.5,0.0043411199999999995,-0.1423818,45.6,1.914657870190251,9.120146623903873,3.5360986807372685e-10,0.2239312454438576,13928.577020859337,17.39264365003314,-0.4522,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPA-330WW,SEG Solar Inc,Multi-c-Si,0,330.0,301.4,1.954,,,72.0,9.11,46.0,8.62,38.3,0.00463699,-0.15341000000000002,44.9,1.8884025683532921,9.112428201558545,2.3881187856687224e-10,0.23380835775440587,877.1900828205623,5.729679765485023,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01B-330,SEG Solar Inc,Mono-c-Si,0,330.0,302.7,1.7,,,340.0,9.31,45.3,8.97,36.8,0.00931,-0.1359,44.4,1.923948036325525,9.310161219168869,5.535964763159009e-10,0.23603967616217203,13630.790434855882,25.108192200400808,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-335-BMB-BG,SEG Solar Inc,Mono-c-Si,1,335.0,311.2,1.72,,,60.0,10.1,41.3,9.6,34.9,0.0031007,-0.1232392,44.0,1.5889282591802854,10.102041794017321,5.172914370449375e-11,0.15419401639198546,762.7408141807977,3.9276413229126517,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-335-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,335.0,310.5,1.82,,,60.0,10.2,41.0,9.69,34.6,0.0054161999999999995,-0.116235,45.69,1.560044632510714,10.202612434399379,3.9093038330356285e-11,0.16080428394687696,627.8449488812627,6.606956718843976,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-335-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,335.0,311.0,1.69,,,60.0,10.2,41.0,9.69,34.6,0.003468,-0.12316400000000001,44.1,1.58873913109736,10.202148714597872,6.289637667175858e-11,0.15427123899801348,732.3293271679217,4.743313631795696,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-335BB,SEG Solar Inc,Mono-c-Si,0,335.0,304.0,1.94,,,1.0,9.23,46.4,8.94,37.5,0.0056303,-0.16425599999999999,45.46,1.956593024414037,9.230002199327204,4.634895587604233e-10,0.2381759084165887,999999.3738202471,4.795005469626293,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-335BW,SEG Solar Inc,Mono-c-Si,0,335.0,304.0,1.94,,,1.0,9.23,46.4,8.94,37.5,0.0056303,-0.16425599999999999,45.46,1.956593024414037,9.230002199327204,4.634895587604233e-10,0.2381759084165887,999999.3738202471,4.795005469626293,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-335WB,SEG Solar Inc,Mono-c-Si,0,335.0,304.9,1.63,,,1.0,9.23,46.4,8.94,37.5,0.004347330000000001,-0.13223999999999997,45.7,1.9213116789782663,9.230197629396908,2.9973599801709583e-10,0.24955423200236868,11655.11635867731,26.03720114423631,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-335WW,SEG Solar Inc,Mono-c-Si,0,335.0,303.2,1.94,,,72.0,9.23,46.4,8.94,37.5,0.004347330000000001,-0.13223999999999997,45.7,1.9213116789782663,9.230197629396908,2.9973599801709583e-10,0.24955423200236868,11655.11635867731,26.03720114423631,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-335BB,SEG Solar Inc,Multi-c-Si,0,335.0,304.2,1.94,,,1.0,9.2,46.2,8.89,37.7,0.0053360000000000005,-0.163548,45.74,1.9313937289615652,9.200002020352704,3.760303785760746e-10,0.21952796979882866,999999.3126208656,3.1001976993703853,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6PA-335BW,SEG Solar Inc,Multi-c-Si,0,335.0,304.2,1.94,,,1.0,9.2,46.2,8.89,37.7,0.0053360000000000005,-0.163548,45.74,1.9313937289615652,9.200002020352704,3.760303785760746e-10,0.21952796979882866,999999.3126208656,3.1001976993703853,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BPA-335WW,SEG Solar Inc,Multi-c-Si,0,335.0,306.1,1.954,,,72.0,9.19,46.2,8.71,38.5,0.00467771,-0.15407700000000002,44.9,1.8958785784172425,9.191594400850388,2.390899819317987e-10,0.22863613095620644,1317.8409181541888,5.659094083100818,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-340-BMB-BG,SEG Solar Inc,Mono-c-Si,1,340.0,315.9,1.72,,,60.0,10.23,41.4,9.72,35.0,0.0031406100000000003,-0.1235376,44.0,1.5934425856065881,10.232227130268244,5.294317215187479e-11,0.15070020817241953,692.219574493302,4.016400929643893,-0.3846,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-340-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,340.0,315.2,1.82,,,60.0,10.32,41.1,9.8,34.7,0.00547992,-0.1165185,45.69,1.5645322067491458,10.32283033962717,3.998824071937123e-11,0.1574235809523328,573.998746197971,6.7032128562209055,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-340-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,340.0,315.7,1.69,,,60.0,10.32,41.1,9.8,34.7,0.0035088000000000003,-0.12346440000000002,44.1,1.5933250356807083,10.322356973410756,6.43397022029985e-11,0.15093909213619636,660.8863304558274,4.837849590867154,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-340BB,SEG Solar Inc,Mono-c-Si,0,340.0,308.6,1.94,,,1.0,9.32,46.6,9.02,37.7,0.0056852000000000005,-0.164964,45.46,1.9652108574706773,9.320002219423987,4.690506528930548e-10,0.23803017725324122,999999.3943167508,4.813853610216071,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-340BW,SEG Solar Inc,Mono-c-Si,0,340.0,308.6,1.94,,,1.0,9.32,46.6,9.02,37.7,0.0056852000000000005,-0.164964,45.46,1.9652108574706773,9.320002219423987,4.690506528930548e-10,0.23803017725324122,999999.3943167508,4.813853610216071,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-340WB,SEG Solar Inc,Mono-c-Si,0,340.0,309.7,1.63,,,1.0,9.32,46.6,9.02,37.7,0.004389720000000001,-0.13280999999999998,45.7,1.9297948421423683,9.320197631659259,3.0342517605566244e-10,0.24934030759799466,11758.54092308802,26.062884116035544,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-340WW,SEG Solar Inc,Mono-c-Si,0,340.0,307.8,1.94,,,72.0,9.32,46.6,9.02,37.7,0.004389720000000001,-0.13280999999999998,45.7,1.9297948421423683,9.320197631659259,3.0342517605566244e-10,0.24934030759799466,11758.54092308802,26.062884116035544,-0.4533,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-340WW,SEG Solar Inc,Mono-c-Si,0,340.0,313.2,1.954,,,72.0,9.32,46.0,8.86,38.4,0.00333656,-0.13353800000000002,45.2,1.7676100838165807,9.321733618510727,4.6329595860514714e-11,0.2452413183110104,1318.4268640210848,6.5123927809932365,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPA-340WW,SEG Solar Inc,Multi-c-Si,0,340.0,310.8,1.954,,,72.0,9.24,46.5,8.77,38.8,0.0047031600000000005,-0.1550775,44.9,1.9048272111231332,9.240004963568582,2.3110875616245788e-10,0.22326016331637966,415214.5036629623,5.312450386924908,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-345-BMB-BG,SEG Solar Inc,Mono-c-Si,0,345.0,319.4,1.87,,,60.0,10.87,40.6,10.27,33.6,0.00377189,-0.12188120000000002,44.3,1.5624909528997426,10.87653780936381,5.58722574133615e-11,0.21677939936481708,360.42531865232945,3.2968032472507884,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-345-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,345.0,320.0,1.82,,,60.0,10.87,40.6,10.27,33.6,0.0057719699999999995,-0.115101,45.69,1.5333907047647155,10.87736439189688,3.409080640332281e-11,0.22294983704484747,329.0787343353916,4.907054933101895,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-345-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,345.0,319.5,1.87,,,60.0,10.87,40.6,10.27,33.6,0.003858849999999999,-0.12046020000000002,44.2,1.5621874855491662,10.876546234276947,5.5590411695532734e-11,0.21684352077004887,360.0679471309862,4.4682993215844435,-0.3875,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-345BB,SEG Solar Inc,Mono-c-Si,0,345.0,313.3,1.94,,,1.0,9.43,46.8,9.11,37.9,0.005752299999999999,-0.16567199999999999,45.46,1.9728307201723778,9.43000230423707,4.699630885526615e-10,0.24424127554274616,999999.4144980597,4.730884844729113,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-345BW,SEG Solar Inc,Mono-c-Si,0,345.0,313.3,1.94,,,1.0,9.43,46.8,9.11,37.9,0.005752299999999999,-0.16567199999999999,45.46,1.9728307201723778,9.43000230423707,4.699630885526615e-10,0.24424127554274616,999999.4144980597,4.730884844729113,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-345WB,SEG Solar Inc,Mono-c-Si,0,345.0,321.9,1.882,,,72.0,9.43,46.8,9.11,37.9,0.0038663,-0.13104000000000002,43.12,1.7611394529109192,9.430003171924309,2.7145398275317807e-11,0.3228622651097909,959893.5471682786,5.61296801412419,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-345WW,SEG Solar Inc,Mono-c-Si,0,345.0,321.9,1.882,,,72.0,9.43,46.8,9.11,37.9,0.0038663,-0.13104000000000002,43.12,1.7611394529109192,9.430003171924309,2.7145398275317807e-11,0.3228622651097909,959893.5471682786,5.61296801412419,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-345WW,SEG Solar Inc,Mono-c-Si,0,345.0,318.0,1.954,,,72.0,9.37,46.3,8.92,38.7,0.0033544599999999996,-0.1344089,45.2,1.7761864498732944,9.370005135977467,4.4765612012042675e-11,0.23997304059943614,437745.38049710257,6.159460628511702,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-BPA-345WW,SEG Solar Inc,Multi-c-Si,0,345.0,315.5,1.954,,,72.0,9.32,46.7,8.85,39.0,0.004743880000000001,-0.1557445,44.9,1.916756525076108,9.320683647990863,2.44078327212249e-10,0.21729779306524197,2962.3677896002287,5.708731291738747,-0.4266,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E11A-345,SEG Solar Inc,Multi-c-Si,0,345.0,314.0,2.03,,,408.0,10.11,43.5,9.76,35.35,0.010110000000000001,-0.17400000000000002,44.6,1.9284331037236722,10.11000172589925,1.6154495741523218e-09,0.17047372352877682,999999.2141317809,1.3500278690213432,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-350-BMB-BG,SEG Solar Inc,Mono-c-Si,0,350.0,324.1,1.87,,,60.0,11.0,40.8,10.36,33.8,0.003817,-0.1224816,44.3,1.5735502347732575,11.008997472956246,5.95396861768276e-11,0.2111426626888861,258.13574027075936,3.7405381703162806,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-350-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,350.0,324.7,1.82,,,60.0,10.98,40.8,10.36,33.8,0.0058303800000000005,-0.11566799999999998,45.69,1.5427845066519417,10.988436433906923,3.548087877971277e-11,0.21786383371249546,283.54930032282715,5.166982184118179,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-350-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,350.0,324.3,1.87,,,60.0,10.98,40.8,10.36,33.8,0.0038979,-0.1210536,44.2,1.5717933709207847,10.987591134421978,5.785731600409733e-11,0.2117595909744268,306.2941899999654,4.725984867182248,-0.3875,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-350BB,SEG Solar Inc,Mono-c-Si,0,350.0,318.0,1.94,,,1.0,9.51,47.0,9.19,38.1,0.0058011,-0.16638,45.46,1.9825077209390058,9.51000225231877,4.810698682003932e-10,0.236729854419889,999999.4331787361,4.857275992705402,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-350BW,SEG Solar Inc,Mono-c-Si,0,350.0,318.0,1.94,,,1.0,9.51,47.0,9.19,38.1,0.0058011,-0.16638,45.46,1.9825077209390058,9.51000225231877,4.810698682003932e-10,0.236729854419889,999999.4331787361,4.857275992705402,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-350WB,SEG Solar Inc,Mono-c-Si,0,350.0,326.7,1.882,,,72.0,9.51,47.0,9.19,38.1,0.0038991000000000004,-0.13160000000000002,43.12,1.769658904619461,9.510003124554812,2.7787040101308896e-11,0.31528826745056454,959659.1928584134,5.740255827509588,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-350WW,SEG Solar Inc,Mono-c-Si,0,350.0,326.7,1.882,,,72.0,9.51,47.0,9.19,38.1,0.0038991000000000004,-0.13160000000000002,43.12,1.769658904619461,9.510003124554812,2.7787040101308896e-11,0.31528826745056454,959659.1928584134,5.740255827509588,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-350WW,SEG Solar Inc,Mono-c-Si,0,350.0,322.7,1.954,,,72.0,9.42,46.6,8.98,39.0,0.00337236,-0.1352798,45.2,1.7905690704592845,9.42025404820858,4.6902262051183294e-11,0.2334769853703173,8657.233843413973,6.514994431210703,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E11A-350,SEG Solar Inc,Multi-c-Si,0,350.0,318.6,2.03,,,408.0,10.2,43.7,9.85,35.55,0.0102,-0.17480000000000004,44.6,1.9386836940865204,10.200001671791856,1.6562929490388027e-09,0.1636713873528159,999999.2969789775,1.4838583878651486,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-355-BMB-BG,SEG Solar Inc,Mono-c-Si,0,355.0,328.9,1.87,,,60.0,11.1,41.0,10.45,34.0,0.0038517000000000004,-0.12308200000000002,44.3,1.5824371222300089,11.10927537361816,6.121220777756459e-11,0.20642423775761695,247.03145847316347,3.8985712196112705,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-355-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,355.0,329.5,1.82,,,60.0,11.08,41.0,10.45,34.0,0.005883480000000001,-0.116235,45.69,1.5514843027135599,11.088749047888681,3.6483211902083754e-11,0.21313187377610265,269.91520650639814,5.329075884838407,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-355-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,355.0,329.0,1.87,,,60.0,11.08,41.0,10.45,34.0,0.0039334,-0.12164700000000002,44.2,1.5806774175230447,11.087897266193455,5.949055162738714e-11,0.2070366823067866,290.47602553006254,4.886424559296274,-0.3875,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-355BB,SEG Solar Inc,Mono-c-Si,0,355.0,322.7,1.94,,,1.0,9.61,47.2,9.27,38.3,0.005862099999999999,-0.16708800000000001,45.46,1.990122745004158,9.610002333168863,4.813961844259239e-10,0.2426713915083696,999989.6015588528,4.774337365129401,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-355BW,SEG Solar Inc,Mono-c-Si,0,355.0,322.7,1.94,,,1.0,9.61,47.2,9.27,38.3,0.005862099999999999,-0.16708800000000001,45.46,1.990122745004158,9.610002333168863,4.813961844259239e-10,0.2426713915083696,999989.6015588528,4.774337365129401,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-355WB,SEG Solar Inc,Mono-c-Si,0,355.0,331.4,1.882,,,72.0,9.61,47.2,9.27,38.3,0.0039401,-0.13216000000000003,43.12,1.7765643004682337,9.610003210594908,2.781806513748987e-11,0.31965567107707743,956835.8401510249,5.6604882830590695,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-355WW,SEG Solar Inc,Mono-c-Si,0,355.0,331.4,1.882,,,72.0,9.61,47.2,9.27,38.3,0.0039401,-0.13216000000000003,43.12,1.7765643004682337,9.610003210594908,2.781806513748987e-11,0.31965567107707743,956835.8401510249,5.6604882830590695,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-355WW,SEG Solar Inc,Mono-c-Si,0,355.0,327.4,1.954,,,72.0,9.47,46.9,9.03,39.3,0.00339026,-0.13615069999999999,45.2,1.8025255742686128,9.470005025990032,4.74696564898013e-11,0.22764506996184877,428196.08644268,6.570719974506258,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E11A-355,SEG Solar Inc,Multi-c-Si,0,355.0,323.3,2.03,,,408.0,10.29,43.9,9.95,35.7,0.01029,-0.1756,44.6,1.948649912719383,10.290001610325955,1.6921774961338931e-09,0.15627559603328461,999999.3005043622,1.5891026162199815,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-360-BMA-BG,SEG Solar Inc,Mono-c-Si,0,360.0,333.7,2.06,,,72.0,9.49,47.8,9.0,40.0,0.00293241,-0.1403886,43.7,1.8352139508280831,9.493195037696012,4.599190467050501e-11,0.2388924103616794,709.5656266139049,5.132735327970735,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-360-BMB-BG,SEG Solar Inc,Mono-c-Si,0,360.0,333.6,1.87,,,60.0,11.2,41.2,10.53,34.2,0.0038864,-0.12368240000000003,44.3,1.5920938255796109,11.210249932673575,6.36348189318385e-11,0.20168931886899796,220.38392681283867,4.154253127664182,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-360-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,360.0,334.3,1.82,,,60.0,11.16,41.2,10.53,34.2,0.00592596,-0.116802,45.69,1.5595334857045673,11.168378369974393,3.706252461782159e-11,0.20892698051744998,278.2910214489943,5.400673334791292,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-360-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,360.0,333.8,1.87,,,60.0,11.16,41.2,10.53,34.2,0.0039618,-0.12224040000000001,44.2,1.5888843468274776,11.167540469545463,6.043227474362e-11,0.20284153203420438,300.2083008328604,4.956858947907475,-0.3875,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-360BB,SEG Solar Inc,Mono-c-Si,0,360.0,327.4,1.94,,,1.0,9.7,47.4,9.36,38.5,0.0059169999999999995,-0.16779599999999997,45.46,1.9998379049539174,9.700002279368185,4.933512366233987e-10,0.2348777130915509,999997.2514193215,4.903316830951589,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-360BW,SEG Solar Inc,Mono-c-Si,0,360.0,327.4,1.94,,,1.0,9.7,47.4,9.36,38.5,0.0059169999999999995,-0.16779599999999997,45.46,1.9998379049539174,9.700002279368185,4.933512366233987e-10,0.2348777130915509,999997.2514193215,4.903316830951589,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-360WB,SEG Solar Inc,Mono-c-Si,0,360.0,336.2,1.882,,,72.0,9.7,47.4,9.36,38.5,0.003977,-0.13272,43.12,1.7851142435067238,9.70000316182115,2.850899944164606e-11,0.31175160697931015,956445.5112981104,5.790376473855681,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-360WW,SEG Solar Inc,Mono-c-Si,0,360.0,336.2,1.882,1.934,0.97,72.0,9.7,47.4,9.36,38.5,0.003977,-0.13272,43.12,1.7851142435067238,9.70000316182115,2.850899944164606e-11,0.31175160697931015,956445.5112981104,5.790376473855681,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-360WW,SEG Solar Inc,Mono-c-Si,0,360.0,332.2,1.954,,,72.0,9.53,47.2,9.09,39.6,0.00341174,-0.13702160000000002,45.2,1.8154512996328853,9.530053508997364,4.8730293153027635e-11,0.2214296604409297,39436.892707007064,6.741906089858889,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01A-360,SEG Solar Inc,Mono-c-Si,0,360.0,327.7,2.04,,,408.0,10.45,43.7,10.12,35.6,0.010450000000000001,-0.13110000000000002,44.4,1.8997073618394398,10.450001587287387,1.0685694356434793e-09,0.15176002032895808,999999.958719227,30.773472962815333,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11A-360,SEG Solar Inc,Multi-c-Si,0,360.0,328.0,2.03,,,408.0,10.39,44.1,10.05,35.85,0.010390000000000002,-0.1764,44.6,1.9575415589125151,10.390001610574553,1.7088971298711087e-09,0.15479483972462163,999999.3167258678,1.590441171179471,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-365-BMA-BG,SEG Solar Inc,Mono-c-Si,0,365.0,338.5,2.06,,,72.0,9.58,48.0,9.08,40.2,0.00296022,-0.140976,43.7,1.8442248958671275,9.583523608521254,4.727338307638235e-11,0.23338981660211283,634.5411246192333,5.288263830695112,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-365-BMB-BG,SEG Solar Inc,Mono-c-Si,0,365.0,338.4,1.87,,,60.0,11.3,41.4,10.62,34.4,0.0039211,-0.1242828,44.3,1.6009785351705015,11.310482474622543,6.53783516390267e-11,0.1971280549769342,212.50202298709848,4.308300870032145,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-365-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,365.0,339.0,1.82,,,60.0,11.26,41.4,10.62,34.4,0.0059790600000000005,-0.11736899999999999,45.69,1.5682317009444373,11.268672612276154,3.808967293425474e-11,0.20434776495509416,265.3128938234468,5.55986369835712,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-365-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,365.0,338.6,1.87,,,60.0,11.26,41.4,10.62,34.4,0.0039973,-0.1228338,44.2,1.5977671772928337,11.267828250745929,6.210623080243226e-11,0.19827099046144642,285.18905109244173,5.114483541190571,-0.3875,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-365BB,SEG Solar Inc,Mono-c-Si,0,365.0,332.1,1.94,,,1.0,9.78,47.6,9.44,38.7,0.005965799999999999,-0.16850400000000001,45.46,2.009513534417737,9.780002227970018,5.047337442605578e-10,0.22770395924236614,999999.4839805936,5.027254533889105,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-365BW,SEG Solar Inc,Mono-c-Si,0,365.0,332.1,1.94,,,1.0,9.78,47.6,9.44,38.7,0.005965799999999999,-0.16850400000000001,45.46,2.009513534417737,9.780002227970018,5.047337442605578e-10,0.22770395924236614,999999.4839805936,5.027254533889105,-0.447,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-365WB,SEG Solar Inc,Mono-c-Si,0,365.0,341.0,1.882,,,72.0,9.78,47.6,9.44,38.7,0.0040098,-0.13328,43.12,1.7936332143020792,9.780003114622303,2.9167137027320925e-11,0.3045248083435217,956253.8168028998,5.915254643725107,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-365WW,SEG Solar Inc,Mono-c-Si,0,365.0,341.0,1.882,,,72.0,9.78,47.6,9.44,38.7,0.0040098,-0.13328,43.12,1.7936332143020792,9.780003114622303,2.9167137027320925e-11,0.3045248083435217,956253.8168028998,5.915254643725107,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-365WW,SEG Solar Inc,Mono-c-Si,0,365.0,336.9,1.954,,,72.0,9.58,47.5,9.15,39.9,0.00342964,-0.1378925,45.2,1.8289081721791478,9.580002864401527,5.0345664098668026e-11,0.21538313712122167,720376.0496715297,6.976934232796984,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01A-365,SEG Solar Inc,Mono-c-Si,0,365.0,332.4,2.04,,,408.0,10.56,43.9,10.2,35.8,0.010560000000000002,-0.13169999999999998,44.4,1.9069358245967774,10.560001716831644,1.0608913253470615e-09,0.1624321036985438,999999.9610582512,30.584376900621177,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11A-365,SEG Solar Inc,Multi-c-Si,0,365.0,332.7,2.03,,,408.0,10.49,44.3,10.13,36.05,0.010490000000000001,-0.17720000000000002,44.6,1.9656266415502395,10.490001681593979,1.7097413949115006e-09,0.16007637077686018,999999.4124228472,1.5148422562761374,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-370-BMA-BG,SEG Solar Inc,Mono-c-Si,0,370.0,343.2,2.06,,,72.0,9.64,48.3,9.14,40.5,0.0029787600000000004,-0.1418571,43.7,1.8566039175062112,9.643318156927247,4.815526729774537e-11,0.22729096190632492,660.3319228951527,5.390898434611813,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-370-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,370.0,343.8,1.82,,,60.0,11.34,41.6,10.7,34.6,0.006021540000000001,-0.117936,45.69,1.5762809538185174,11.348309257294005,3.8681179979976554e-11,0.20027617951049262,273.32549546821525,5.629663970174316,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-370-BMB-HV {Wht},SEG Solar Inc,Mono-c-Si,0,370.0,343.3,1.87,,,60.0,11.34,41.6,10.7,34.6,0.004025699999999999,-0.12342720000000001,44.2,1.605974418257396,11.34747879179397,6.306793234333834e-11,0.19420881384075941,294.4764380037735,5.183177896711337,-0.3875,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-370WB,SEG Solar Inc,Mono-c-Si,0,370.0,345.8,1.882,,,72.0,9.88,47.8,9.52,38.9,0.004050800000000001,-0.13384000000000001,43.12,1.800560759004794,9.880003195516572,2.9202188940920276e-11,0.3084089333073268,953586.5787251969,5.838546516750597,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-370WW,SEG Solar Inc,Mono-c-Si,0,370.0,345.8,1.882,,,72.0,9.88,47.8,9.52,38.9,0.004050800000000001,-0.13384000000000001,43.12,1.800560759004794,9.880003195516572,2.9202188940920276e-11,0.3084089333073268,953586.5787251969,5.838546516750597,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-370WW,SEG Solar Inc,Mono-c-Si,0,370.0,341.7,1.954,,,72.0,9.63,47.8,9.2,40.2,0.0034475400000000002,-0.1387634,45.2,1.841636346543762,9.630002837755422,5.145559567448237e-11,0.20959187048176145,711281.390506972,7.119945039620221,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01A-370,SEG Solar Inc,Mono-c-Si,0,370.0,337.1,2.04,,,408.0,10.65,44.1,10.28,36.0,0.010650000000000001,-0.1323,44.4,1.915898661026673,10.65000172417444,1.0734769328542792e-09,0.16174726622423355,999999.963129195,30.619716992308234,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11A-370,SEG Solar Inc,Multi-c-Si,0,370.0,337.4,2.03,,,408.0,10.58,44.5,10.21,36.25,0.01058,-0.17800000000000002,44.6,1.974785999472518,10.580001689350729,1.7300321174448924e-09,0.15944441499368345,999999.4866112362,1.5419204709046588,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-375-BMA-BG,SEG Solar Inc,Mono-c-Si,0,375.0,348.0,2.06,,,72.0,9.73,48.5,9.22,40.7,0.0030065700000000005,-0.1424445,43.7,1.865613670840668,9.733625314883982,4.947170455367819e-11,0.2219737856526336,595.7565181708936,5.543637207583097,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-375-BMB-HV {Blk},SEG Solar Inc,Mono-c-Si,0,375.0,348.6,1.82,,,60.0,11.42,41.8,10.79,34.8,0.00606402,-0.11850299999999998,45.69,1.583602987333248,11.427261251091117,3.8845898490074965e-11,0.19635437833834746,308.81276654869714,5.600782287777788,-0.3566,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-375WB,SEG Solar Inc,Mono-c-Si,0,375.0,350.6,1.882,,,72.0,9.96,48.0,9.6,39.1,0.004083600000000001,-0.13440000000000002,43.12,1.8090809098820235,9.960003148460476,2.986787472334449e-11,0.3013793152543459,953436.5385497382,5.9623317057373875,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-375WW,SEG Solar Inc,Mono-c-Si,0,375.0,350.6,1.882,,,72.0,9.96,48.0,9.6,39.1,0.004083600000000001,-0.13440000000000002,43.12,1.8090809098820235,9.960003148460476,2.986787472334449e-11,0.3013793152543459,953436.5385497382,5.9623317057373875,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-BMA-375WW,SEG Solar Inc,Mono-c-Si,0,375.0,346.4,1.954,,,72.0,9.7,48.1,9.26,40.5,0.0034725999999999993,-0.13963430000000002,45.2,1.85354647038623,9.700002830516313,5.208552653842188e-11,0.2036304775836314,697853.1734200127,7.162409464928571,-0.3855,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01A-375,SEG Solar Inc,Mono-c-Si,0,375.0,341.8,2.04,,,408.0,10.74,44.3,10.36,36.2,0.010740000000000001,-0.1329,44.4,1.9248665678453436,10.740001730524398,1.086166673491216e-09,0.16098157814759367,999999.9646878386,30.65538631358065,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E11A-375,SEG Solar Inc,Multi-c-Si,0,375.0,342.1,2.03,,,408.0,10.68,44.7,10.29,36.45,0.010680000000000002,-0.17880000000000004,44.6,1.9829231189315086,10.680001752864232,1.7317925789344948e-09,0.16388575288377005,999999.565699663,1.4721340956958395,-0.451,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-380-6MA-HV,SEG Solar Inc,Mono-c-Si,0,380.0,352.2,1.87,,,72.0,9.93,49.1,9.65,39.4,0.0032868299999999997,-0.14788920000000003,44.3,1.8861291640597562,9.93021517954959,4.911190218657449e-11,0.30580923976048185,14112.3393795799,2.620568825397001,-0.3954,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-380-BMA-BG,SEG Solar Inc,Mono-c-Si,0,380.0,352.7,2.06,,,72.0,9.81,48.7,9.3,40.9,0.0030312900000000003,-0.14303190000000002,43.7,1.8736536281898675,9.813384852702816,5.014180099030324e-11,0.21716424577114882,629.3867133499027,5.586655595163016,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-6MA-380WB,SEG Solar Inc,Mono-c-Si,0,380.0,355.4,1.882,,,72.0,10.02,48.3,9.65,39.4,0.0041082,-0.13524,43.12,1.8208605163115765,10.020003151103651,3.025555127665729e-11,0.2998017389384132,953358.9325480799,6.021300870546257,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-6MA-380WW,SEG Solar Inc,Mono-c-Si,0,380.0,355.4,1.882,,,72.0,10.02,48.3,9.65,39.4,0.0041082,-0.13524,43.12,1.8208605163115765,10.020003151103651,3.025555127665729e-11,0.2998017389384132,953358.9325480799,6.021300870546257,-0.372,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-E01A-380,SEG Solar Inc,Mono-c-Si,0,380.0,346.5,2.04,,,408.0,10.84,44.5,10.44,36.4,0.01084,-0.1335,44.4,1.9330022210717477,10.840001789477228,1.0890663738176393e-09,0.1649258633761373,999999.4327695285,30.584821693044912,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-385-6MA-HV,SEG Solar Inc,Mono-c-Si,0,385.0,356.9,1.87,,,72.0,9.98,49.4,9.7,39.7,0.00330338,-0.1487928,44.3,1.8990344314983916,9.980210771631876,5.030252473024672e-11,0.2984768571702705,14132.828432896173,2.7769632149092214,-0.3954,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-385-BMA-BG,SEG Solar Inc,Mono-c-Si,0,385.0,357.5,2.06,,,72.0,9.88,48.9,9.37,41.1,0.0030529200000000006,-0.1436193,43.7,1.8817486238518606,9.883176931162751,5.079902779903838e-11,0.21264045512829877,661.294675274605,5.635446830130984,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-385-BMA-HV,SEG Solar Inc,Mono-c-Si,0,385.0,357.3,2.02,,,72.0,9.8,48.3,9.32,40.8,0.0031948,-0.1402149,44.0,1.8627610304769133,9.801672978982939,5.3506511287937584e-11,0.18657592790807595,1092.9271734583808,7.362948983508978,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01A-385,SEG Solar Inc,Mono-c-Si,0,385.0,351.2,2.04,,,408.0,10.93,44.7,10.52,36.6,0.01093,-0.13410000000000002,44.4,1.941984485022665,10.930001792952226,1.101950286066573e-09,0.16388659983999285,999999.9682597878,30.622146723708852,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-390-6MA-HV,SEG Solar Inc,Mono-c-Si,0,390.0,361.7,1.87,,,72.0,10.05,49.7,9.77,40.0,0.0033265499999999997,-0.14969640000000003,44.3,1.9114968065814835,10.050002937775453,5.1317021998097494e-11,0.29227726081377153,999931.2691629047,2.8831475778819997,-0.3954,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-390-BMA-BG,SEG Solar Inc,Mono-c-Si,0,390.0,362.3,2.06,,,72.0,9.96,49.1,9.45,41.3,0.0030776400000000004,-0.14420670000000002,43.7,1.8897931623241353,9.96295060139218,5.147883106756525e-11,0.20798516542722895,702.0712201409461,5.678236108920268,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-390-BMA-HV,SEG Solar Inc,Mono-c-Si,0,390.0,362.0,2.02,,,72.0,9.87,48.5,9.4,41.0,0.0032176199999999996,-0.1407955,44.0,1.8698640484020919,9.87104166454884,5.352061232142575e-11,0.18252214847772097,1729.4375214062534,7.29766039884242,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-390-BMD-BG,SEG Solar Inc,Mono-c-Si,1,390.0,368.6,1.96,,,54.0,13.4,36.9,12.78,30.59,0.007048400000000001,-0.088929,43.2,1.3089408140413124,13.40242067936298,7.635891160671774e-12,0.17387553354547583,962.5116899007202,7.521130452564907,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-390-BMD-HV,SEG Solar Inc,Mono-c-Si,0,390.0,362.2,1.96,,,54.0,13.4,36.9,12.78,30.59,0.0007638,-0.1019178,45.41,1.3231259907840658,13.40193618983683,1.0335617546250886e-11,0.17140243396178992,1186.24342996195,-3.282296658602279,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-390-BMD-TB,SEG Solar Inc,Mono-c-Si,0,390.0,364.7,1.96,,,54.0,13.4,36.9,12.78,30.59,0.0047302,-0.0909216,43.2,1.353957568426737,13.40000509826728,1.9547177320565635e-11,0.16604439199648882,436428.75606539426,13.751141449604074,-0.3682,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-E01A-390,SEG Solar Inc,Mono-c-Si,0,390.0,355.9,2.04,,,408.0,11.02,44.9,10.6,36.8,0.01102,-0.1347,44.4,1.95154246113131,11.02016337727835,1.122070568214136e-09,0.16121126403695638,10874.01036118,30.729219026448664,-0.459,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-395-6MA-HV,SEG Solar Inc,Mono-c-Si,0,395.0,366.5,1.87,,,72.0,10.11,49.9,9.83,40.2,0.0033464099999999997,-0.1502988,44.3,1.9201609162220936,10.110002893605019,5.2307312711978565e-11,0.2861744164001823,999931.5182657446,2.9921159362378447,-0.3954,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-395-BMA-BG,SEG Solar Inc,Mono-c-Si,0,395.0,367.0,2.06,,,72.0,10.04,49.3,9.52,41.5,0.0031023599999999998,-0.1447941,43.7,1.898850252940317,10.04325996003859,5.282415590979574e-11,0.20319753883184935,625.8062459096883,5.832576852485606,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-395-BMA-HV,SEG Solar Inc,Mono-c-Si,0,395.0,366.8,2.02,,,72.0,9.95,48.7,9.47,41.2,0.0032436999999999995,-0.1413761,44.0,1.8789311717767432,9.951340187533168,5.492811018139248e-11,0.17789632939882893,1320.7617799271457,7.455307736267609,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-395-BMD-BG,SEG Solar Inc,Mono-c-Si,1,395.0,373.4,1.96,,,54.0,13.5,37.01,12.88,30.69,0.0071010000000000005,-0.0891941,43.2,1.3128120619476165,13.502073229294902,7.690810861319515e-12,0.17232754277043924,1122.124576317749,7.517232903100769,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-395-BMD-HV,SEG Solar Inc,Mono-c-Si,0,395.0,367.0,1.96,,,54.0,13.5,37.01,12.88,30.69,0.0007695000000000001,-0.10222162,45.41,1.32576221850375,13.500005383770691,1.0152177822482568e-11,0.17005906266498186,426432.9982207966,-3.4891383347562526,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-395-BMD-TB,SEG Solar Inc,Mono-c-Si,0,395.0,369.5,1.96,,,54.0,13.5,37.01,12.88,30.69,0.0047655,-0.09119264,43.2,1.335896842871505,13.501299829917253,1.2528462093993559e-11,0.16833854652929056,1748.3598785657407,9.656817998567131,-0.3682,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-400-6MA-HV,SEG Solar Inc,Mono-c-Si,0,400.0,371.3,1.87,,,72.0,10.24,50.1,9.88,40.5,0.00338944,-0.1509012,44.3,1.9248854636456845,10.240275164931777,5.087710100507316e-11,0.3176075400200525,11819.470537941903,2.658505394165859,-0.3954,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-400-BMA-BG,SEG Solar Inc,Mono-c-Si,0,400.0,371.8,2.06,,,72.0,10.12,49.5,9.6,41.7,0.00312708,-0.1453815,43.7,1.9068957256821726,10.123037672040768,5.3517062272046705e-11,0.19869398772562347,661.9487537848388,5.874323462704519,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-400-BMA-HV,SEG Solar Inc,Mono-c-Si,0,400.0,371.6,2.02,,,72.0,10.03,48.9,9.55,41.4,0.00326978,-0.1419567,44.0,1.8869946778681008,10.031172698648962,5.565695800054232e-11,0.17357743341174503,1484.5943445529592,7.498477924496963,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-400-BMD-BG,SEG Solar Inc,Mono-c-Si,1,400.0,378.2,1.96,,,54.0,13.6,37.12,12.99,30.81,0.0071536,-0.08945919999999999,43.2,1.3166385653465376,13.600960815213377,7.744737790552118e-12,0.16906046014612336,2392.991195078755,7.508986588808528,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-400-BMD-HV,SEG Solar Inc,Mono-c-Si,0,400.0,371.8,1.96,,,54.0,13.6,37.12,12.99,30.81,0.0007752000000000001,-0.10252544,45.41,1.330299856049665,13.600005284845084,1.0356366980002838e-11,0.1667069627341076,429006.8373930085,-3.391172523636687,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-400-BMD-TB,SEG Solar Inc,Mono-c-Si,0,400.0,374.3,1.96,,,54.0,13.6,37.12,12.99,30.81,0.0048008,-0.09146367999999999,43.2,1.3819354397036605,13.61421510834759,2.940763462912712e-11,0.1578358856446479,999999.415203974,17.423282600488704,-0.3682,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-405-BMA-BG,SEG Solar Inc,Mono-c-Si,0,405.0,376.6,2.06,,,72.0,10.19,49.7,9.67,41.9,0.00314871,-0.1459689,43.7,1.914994898137557,10.192845511680458,5.419606428097532e-11,0.19444397691709187,696.3191213918332,5.921615584242575,-0.3866,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-405-BMA-HV,SEG Solar Inc,Mono-c-Si,0,405.0,376.3,2.02,,,72.0,10.15,49.4,9.67,41.9,0.0033089,-0.1434082,44.0,1.9075382506986887,10.150936420255542,5.731702588054177e-11,0.1642817944507921,1780.6752324162978,7.647820503909613,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-405-BMD-BG,SEG Solar Inc,Mono-c-Si,1,405.0,383.0,1.96,,,54.0,13.7,37.22,13.1,30.93,0.007206199999999999,-0.0897002,43.2,1.3210169334568536,13.700611291666025,7.944367112345591e-12,0.1649658917966713,3697.1432400972644,7.667424721850882,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-405-BMD-HV,SEG Solar Inc,Mono-c-Si,0,405.0,376.5,1.96,,,54.0,13.7,37.22,13.1,30.93,0.0007809,-0.10280164,45.41,1.3171400562654263,13.70000365135171,7.316663235775317e-12,0.1656222025848263,521577.0360171615,-6.146634021327001,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-405-BMD-TB,SEG Solar Inc,Mono-c-Si,0,405.0,379.1,1.96,,,54.0,13.7,37.22,13.1,30.93,0.004836099999999999,-0.09171008,43.2,1.3877914897183588,13.70008133311048,3.083736348969702e-11,0.1537074298078736,25890.988983613235,17.81475990405346,-0.3682,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-410-BMA-HV,SEG Solar Inc,Mono-c-Si,0,410.0,381.1,2.02,,,72.0,10.23,49.6,9.74,42.1,0.00333498,-0.14398880000000003,44.0,1.9166029795473956,10.231205433865064,5.877779892715615e-11,0.15991726306120413,1357.1492854366409,7.800947643102735,-0.3863,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-410-BMD-BG,SEG Solar Inc,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.8,37.32,13.21,31.05,0.006789600000000001,-0.08262648000000002,43.4,1.3277662530761023,13.800081684236519,8.569753563402348e-12,0.16053585070379067,27121.4601328837,17.985212820846428,-0.3216,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-410-BMD-HV,SEG Solar Inc,Mono-c-Si,0,410.0,381.3,1.96,,,54.0,13.8,37.32,13.21,31.05,0.0007866000000000001,-0.10307784,45.41,1.340161152046494,13.800004056951682,1.1114912994662244e-11,0.15844838600491512,538979.1481127219,-2.9516859089198078,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-410-BMD-TB,SEG Solar Inc,Mono-c-Si,0,410.0,383.9,1.96,,,54.0,13.8,37.32,13.21,31.05,0.0048714000000000006,-0.09195648000000001,43.2,1.2769898314868366,13.800360433813191,2.801962310970491e-12,0.1691641415312251,6476.82086371484,-3.191291927422752,-0.3682,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-415-BMB-BG,SEG Solar Inc,Mono-c-Si,1,415.0,390.0,2.16,,,60.0,13.06,40.62,12.39,33.55,0.0054068399999999996,-0.10431215999999999,43.3,1.4710979891659721,13.066855327685362,1.3210052744054273e-11,0.20243868411824412,385.6634374851062,5.8729739749421555,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-415-BMB-HV,SEG Solar Inc,Mono-c-Si,0,415.0,392.0,2.16,,,60.0,13.06,40.62,12.39,33.55,0.0061382,-0.09748799999999999,43.1,1.433137575551678,13.068240205293852,6.349547086432413e-12,0.20925026682252548,331.6432358870497,6.677227152281718,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-415-BMB-TB,SEG Solar Inc,Mono-c-Si,0,415.0,388.2,2.16,,,60.0,13.06,40.62,12.39,33.55,0.00480608,-0.10650564,43.4,1.5021012688289404,13.065783232429453,2.338007943568407e-11,0.19692415716701564,444.70450931818715,8.654301570982623,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-415-BMD-BG,SEG Solar Inc,Mono-c-Si,1,415.0,392.7,1.96,,,54.0,13.9,37.42,13.32,31.17,0.007311400000000001,-0.0901822,43.2,1.3277148489261783,13.90060163100845,7.992070597527072e-12,0.15733370723764825,3635.0165162283492,7.592372118470219,-0.3125,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-415-BMD-HV,SEG Solar Inc,Mono-c-Si,0,415.0,386.1,1.96,,,54.0,13.9,37.42,13.32,31.16,0.0007923000000000001,-0.10335404000000001,45.41,1.344911742384139,13.900004008821059,1.1467513925975898e-11,0.1552739723725376,538395.8870143485,-2.7630040941166962,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-415-BMD-TB,SEG Solar Inc,Mono-c-Si,0,415.0,388.7,1.96,,,54.0,13.9,37.42,13.32,31.17,0.0049067,-0.09220288000000001,43.2,1.3269455383954376,13.900004047685432,7.86799224685628e-12,0.1574525164643537,540706.0157324562,5.319589456380412,-0.3682,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMA-BG,SEG Solar Inc,Mono-c-Si,0,420.0,389.8,1.87,,,72.0,10.97,48.9,10.32,40.7,0.00377368,-0.14552639999999997,45.3,1.8815911509856622,10.97949562262269,5.5803120845855044e-11,0.23447749863429806,270.88461469236,4.141478872392827,-0.3838,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMA-HV,SEG Solar Inc,Mono-c-Si,0,420.0,389.0,2.22,,,72.0,10.97,48.9,10.32,40.7,0.0036530100000000004,-0.1475313,44.5,1.8833747609012008,10.97945220155422,5.719619418108676e-11,0.23409984424328073,271.6907084383031,2.9376753032457796,-0.3852,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMB-BG,SEG Solar Inc,Mono-c-Si,1,420.0,394.8,2.16,,,60.0,13.16,40.72,12.51,33.63,0.00544824,-0.10456895999999999,43.3,1.4732942547725352,13.164765220765194,1.2990963923115849e-11,0.2016790053909811,556.9722534017557,5.6543572355299645,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMB-HV,SEG Solar Inc,Mono-c-Si,0,420.0,396.9,2.16,,,60.0,13.16,40.72,12.51,33.63,0.0061852,-0.097728,43.1,1.435322560063755,13.166091605041917,6.245390880699363e-12,0.20842383207630574,450.2684641156988,6.456593101834004,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMB-TB,SEG Solar Inc,Mono-c-Si,0,420.0,393.0,2.16,,,60.0,13.16,40.72,12.51,33.63,0.00484288,-0.10676784,43.4,1.461824831735512,13.165157453450504,1.0454494318362607e-11,0.20370937756727284,519.7944030105527,1.7160685553495862,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMD-BG,SEG Solar Inc,Mono-c-Si,1,420.0,396.7,1.95,,,54.0,14.0,37.52,13.43,31.28,0.006888000000000001,-0.08306928000000001,43.4,1.2898759697734075,14.000625482225631,3.2586485514089867e-12,0.16131096900340156,3610.5800125192827,8.825911240829761,-0.3216,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BMD-TB,SEG Solar Inc,Mono-c-Si,0,420.0,395.3,1.96,,,54.0,14.0,37.52,13.43,31.28,0.005372780000000001,-0.091297416,43.8,1.348896567645139,14.000002120500904,1.1643502083123104e-11,0.15146063704940202,999997.5100627108,10.01372974801097,-0.33342,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-420-BTD-BG,SEG Solar Inc,Mono-c-Si,1,420.0,395.1,1.94,,,54.0,13.83,38.5,13.17,31.9,0.00537987,-0.09867549999999999,43.4,1.4022937686375077,13.832885803833674,1.643892777008894e-11,0.17109444934033544,819.9574292050779,7.498523270542743,-0.3444,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-425-BMA-BG,SEG Solar Inc,Mono-c-Si,0,425.0,394.6,1.87,,,72.0,11.04,49.2,10.4,40.9,0.00379776,-0.1464192,45.3,1.890604816112174,11.048732913835417,5.4333504427006356e-11,0.24013027524756292,303.56859294934884,3.858763102070075,-0.3838,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-425-BMA-HV,SEG Solar Inc,Mono-c-Si,0,425.0,393.7,2.22,,,72.0,11.04,49.2,10.4,40.9,0.0036763200000000003,-0.14843640000000002,44.5,1.8923900345067057,11.048690240832885,5.568642338311108e-11,0.239755632428461,304.5833003529383,2.657795394301266,-0.3852,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-425-BMB-BG,SEG Solar Inc,Mono-c-Si,1,425.0,399.6,2.16,,,60.0,13.25,40.82,12.61,33.77,0.0054855,-0.10482575999999999,43.3,1.4729983675402034,13.250005769119747,1.2217012991810198e-11,0.19630282395398585,450855.45492390875,5.0491427403793265,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-425-BMB-HV,SEG Solar Inc,Mono-c-Si,0,425.0,401.7,2.16,,,60.0,13.25,40.82,12.61,33.77,0.0062275,-0.097968,43.1,1.439279061285245,13.254881837200774,6.349282149324564e-12,0.20232555233585225,549.1403086978161,6.536636076192419,-0.3124,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-425-BMB-TB,SEG Solar Inc,Mono-c-Si,0,425.0,397.8,2.16,,,60.0,13.25,40.82,12.61,33.77,0.004876,-0.10703003999999999,43.4,1.508482073088665,13.252639236565951,2.3375101247812962e-11,0.19016634869660745,954.7094977705182,8.511693073047404,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-425-BMD-BG,SEG Solar Inc,Mono-c-Si,1,425.0,401.5,1.95,,,54.0,14.1,37.62,13.54,31.39,0.006937199999999999,-0.08329068,43.4,1.2931440285020677,14.100621920187614,3.269410967585748e-12,0.15841013699838916,3591.4302678505787,8.791469174639508,-0.3216,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-425-BMD-TB,SEG Solar Inc,Mono-c-Si,0,425.0,400.1,1.96,,,54.0,14.1,37.62,13.54,31.39,0.005411157,-0.09154074599999999,43.8,1.3535962721304775,14.100056801594517,1.1995094554003686e-11,0.1484023657824767,36838.32352624338,10.217003541734153,-0.33342,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-425-BTD-BG,SEG Solar Inc,Mono-c-Si,1,425.0,399.9,1.94,,,54.0,13.91,38.7,13.24,32.1,0.00541099,-0.09918809999999999,43.4,1.4106259704339175,13.913427962340089,1.686361584604153e-11,0.1680102794944906,681.7528338228925,7.673565439617791,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-430-BMA-BG,SEG Solar Inc,Mono-c-Si,0,430.0,399.4,1.87,,,72.0,11.11,49.4,10.47,41.1,0.0038218399999999995,-0.1470144,45.3,1.878075688645699,11.110008587677429,4.190201562458736e-11,0.23989612965238608,310228.62981063256,1.6082491718741787,-0.3838,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-430-BMA-HV,SEG Solar Inc,Mono-c-Si,0,430.0,398.5,2.22,,,72.0,11.11,49.4,10.47,41.1,0.00369963,-0.1490398,44.5,1.9005388051736287,11.118372909776637,5.641146883813133e-11,0.235533360697196,312.5288292101088,2.7111539386933226,-0.3852,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-430-BMB-BG,SEG Solar Inc,Mono-c-Si,1,430.0,404.4,2.16,,,60.0,13.36,40.92,12.72,33.85,0.00553104,-0.10508255999999999,43.3,1.4806439032585257,13.363201674826042,1.3238450486299338e-11,0.19472837757703104,812.5657093134014,5.680536523308401,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-430-BMB-HV,SEG Solar Inc,Mono-c-Si,0,430.0,406.5,2.16,,,60.0,13.36,40.92,12.72,33.85,0.0062791999999999995,-0.098208,43.1,1.4424811084486575,13.364465460452802,6.364508016733044e-12,0.20140093703279802,602.5619458797298,6.483340628191349,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-430-BMB-TB,SEG Solar Inc,Mono-c-Si,0,430.0,402.6,2.16,,,60.0,13.36,40.92,12.72,33.85,0.00491648,-0.10729224,43.4,1.5118201446565578,13.362228317350533,2.3430528695580776e-11,0.18932503733344744,1135.108749203674,8.457932485476388,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-430-BTD-BG,SEG Solar Inc,Mono-c-Si,1,430.0,408.0,1.94,,,54.0,13.99,38.9,13.32,32.3,0.005791859999999999,-0.0880307,43.3,1.345145739218064,13.995753436668824,3.8362970851016836e-12,0.17729721611789812,431.1141680941361,8.040537341207799,-0.3021,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BMA-BG,SEG Solar Inc,Mono-c-Si,0,435.0,404.2,1.87,,,72.0,11.18,49.6,10.54,41.3,0.00384592,-0.1476096,45.3,1.886676232806057,11.180007695132671,4.275627467330122e-11,0.23561842437830907,342327.8832700112,1.7220735391521527,-0.3838,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BMA-HV,SEG Solar Inc,Mono-c-Si,0,435.0,403.2,2.22,,,72.0,11.18,49.6,10.54,41.3,0.00372294,-0.14964320000000003,44.5,1.8884454320799116,11.180009896251061,4.382226326128487e-11,0.23525107029130699,265771.572574773,0.5468646563152866,-0.3852,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BMB-BG,SEG Solar Inc,Mono-c-Si,1,435.0,409.2,2.16,,,60.0,13.45,41.01,12.82,33.98,0.0055683,-0.10531367999999998,43.3,1.484329221728379,13.452120042709078,1.344986962562806e-11,0.18891493411627486,1198.5163912735245,5.754671364377613,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BMB-HV,SEG Solar Inc,Mono-c-Si,0,435.0,411.3,2.16,,,60.0,13.45,41.01,12.82,33.98,0.006321500000000001,-0.09842399999999998,43.1,1.4460596765033682,13.453324929593045,6.466022484352071e-12,0.19556035182838316,791.0804379129744,6.558477729077351,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BMB-TB,SEG Solar Inc,Mono-c-Si,0,435.0,407.4,2.16,,,60.0,13.45,41.01,12.82,33.98,0.0049496,-0.10752821999999998,43.4,1.5155888524392551,13.45119486567503,2.3803260043446617e-11,0.18353421741043716,2065.9522756289566,8.533084347186522,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BTD-BG,SEG Solar Inc,Mono-c-Si,1,435.0,409.6,1.94,,,54.0,14.07,39.1,13.39,32.5,0.00547323,-0.10021329999999999,43.4,1.4267967632164682,14.073689428654856,1.7580268064707146e-11,0.16197029855626213,617.6897174757529,7.939361826249038,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-435-BTD-HV,SEG Solar Inc,Mono-c-Si,1,435.0,415.0,1.89,,,18.0,13.86,39.12,13.12,33.17,0.00551628,-0.09181463999999999,43.5,1.3198207048100632,13.870698971722996,1.828329701142665e-12,0.12910206947525318,167.24548451165143,-1.9185100550139742,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BMA-BG,SEG Solar Inc,Mono-c-Si,0,440.0,409.0,1.87,,,72.0,11.27,49.7,10.63,41.4,0.0038768799999999996,-0.14790720000000002,45.3,1.9106601814379907,11.277777891639381,5.617715034463735e-11,0.22859895714127632,331.23504290196945,3.9608922299011287,-0.3838,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BMA-HV,SEG Solar Inc,Mono-c-Si,0,440.0,408.0,2.22,,,72.0,11.27,49.7,10.63,41.4,0.0037529100000000004,-0.14994490000000002,44.5,1.8930010385582177,11.270009063913555,4.463610531533559e-11,0.23193105656490465,288385.5109952782,0.6309492438600913,-0.3852,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BMB-BG,SEG Solar Inc,Mono-c-Si,1,440.0,414.0,2.16,,,60.0,13.56,41.12,12.92,34.08,0.00561384,-0.10559616,43.3,1.4887575532517718,13.562540167941817,1.3666471176587556e-11,0.18708826604733292,998.7201694882779,5.82387469959294,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BMB-HV,SEG Solar Inc,Mono-c-Si,0,440.0,416.2,2.16,,,60.0,13.56,41.12,12.92,34.08,0.0063732,-0.098688,43.1,1.450359876487537,13.563763849046632,6.569812245865028e-12,0.19370614765641817,697.8642043137472,6.628366034245857,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BMB-TB,SEG Solar Inc,Mono-c-Si,0,440.0,412.2,2.16,,,60.0,13.56,41.12,12.92,34.08,0.00499008,-0.10781663999999999,43.4,1.5201187521221249,13.561600336470194,2.4186004982229715e-11,0.18173037883909804,1539.8432545734959,8.603512336697776,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BTD-BG,SEG Solar Inc,Mono-c-Si,1,440.0,420.8,1.89,,,54.0,13.92,39.28,13.2,33.32,0.00608304,-0.09109032,43.3,1.3138663169118936,13.929699578681547,1.4237545287875349e-12,0.12982980538082375,186.32055588534115,-2.880701169826689,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BTD-HV,SEG Solar Inc,Mono-c-Si,1,440.0,419.9,1.89,,,18.0,13.92,39.28,13.2,33.32,0.00554016,-0.09219016000000001,43.5,1.3244393058637813,13.929340430449368,1.808120395674765e-12,0.12796336204988917,190.7032063731978,-2.052571285436085,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-440-BTE-BG,SEG Solar Inc,Mono-c-Si,1,440.0,418.7,1.93,,,16.0,15.77,35.47,14.96,29.42,0.0086735,-0.08417031000000001,43.2,1.2314815331134097,15.780923326894822,4.83722987304871e-12,0.14526659261106706,209.721281255248,3.7763390264012426,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BMA-BG,SEG Solar Inc,Mono-c-Si,0,445.0,413.8,1.87,,,72.0,11.34,49.9,10.7,41.6,0.00390096,-0.14850239999999998,45.3,1.8998249776358715,11.340007546324443,4.4423465950576525e-11,0.22813246804969398,342824.6978208917,1.9192259035977768,-0.3838,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BMA-HV,SEG Solar Inc,Mono-c-Si,0,445.0,412.8,2.22,,,72.0,11.34,49.9,10.7,41.6,0.0037762200000000003,-0.15054830000000002,44.5,1.9016129729630822,11.340009555600107,4.553406996904259e-11,0.22776661816189983,270303.1713382241,0.7422145323179292,-0.3852,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BMB-BG,SEG Solar Inc,Mono-c-Si,1,445.0,418.8,2.16,,,60.0,13.66,41.22,13.03,34.18,0.00565524,-0.10585296,43.3,1.4919681403370217,13.661406342158097,1.3680573877664173e-11,0.18470065918214695,1794.0236953544033,5.764581386949702,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BMB-HV,SEG Solar Inc,Mono-c-Si,0,445.0,421.0,2.16,,,60.0,13.66,41.22,13.03,34.18,0.0064202,-0.098928,43.1,1.4535012989416778,13.662589833251404,6.577007312245754e-12,0.1912752687136332,1008.875853494958,6.568623761418709,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BMB-TB,SEG Solar Inc,Mono-c-Si,0,445.0,417.0,2.16,,,60.0,13.66,41.22,13.03,34.18,0.00502688,-0.10807884,43.4,1.5233882150078002,13.66049929333719,2.4211030559240197e-11,0.17937738915946194,4907.528218733916,8.543012699641222,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BTD-BG,SEG Solar Inc,Mono-c-Si,1,445.0,425.7,1.89,,,54.0,13.98,39.44,13.29,33.48,0.006109260000000001,-0.09146135999999999,43.3,1.3182018704535168,13.98773476973576,1.401277859986996e-12,0.127896214620683,231.16254815669419,-3.0561650126870665,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BTD-HV,SEG Solar Inc,Mono-c-Si,1,445.0,424.8,1.89,,,18.0,13.98,39.44,13.29,33.48,0.005564040000000001,-0.09256567999999998,43.5,1.3288007912971087,13.98740474948838,1.7795502046487005e-12,0.12603799332689267,237.95688847499036,-2.2288927864915897,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-445-BTE-BG,SEG Solar Inc,Mono-c-Si,1,445.0,423.6,1.93,,,16.0,15.83,35.64,15.04,29.6,0.0087065,-0.08457372,43.2,1.2373113978544017,15.838961325167963,4.8555532525306946e-12,0.14247220260178964,251.67427044369222,3.7698952479265904,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BMA-BG,SEG Solar Inc,Mono-c-Si,0,450.0,422.7,2.15,,,72.0,11.42,50.1,10.77,41.8,0.0039513199999999995,-0.1293081,43.3,1.8219653628914343,11.420007342143498,1.3047516123038677e-11,0.24161153279084743,375805.93398712995,6.447455691432858,-0.3496,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BMB-BG,SEG Solar Inc,Mono-c-Si,1,450.0,423.6,2.16,,,60.0,13.76,41.32,13.13,34.28,0.00569664,-0.10610976,43.3,1.495711095160249,13.761082655393094,1.3817185271828226e-11,0.182324898530795,2317.256958302869,5.7859213176760935,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BMB-HV,SEG Solar Inc,Mono-c-Si,0,450.0,425.8,2.16,,,60.0,13.76,41.32,13.13,34.28,0.0064672,-0.09916799999999999,43.1,1.457144379654065,13.762253495902673,6.64264840454356e-12,0.18886826558432224,1153.2425550887094,6.590253827821539,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BMB-TB,SEG Solar Inc,Mono-c-Si,0,450.0,421.8,2.16,,,60.0,13.76,41.32,13.13,34.28,0.00506368,-0.10834104,43.4,1.5272116364699921,13.760186266054427,2.4452359180839588e-11,0.17702710896320703,13077.494197904532,8.564640423535042,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BTD-BG,SEG Solar Inc,Mono-c-Si,1,450.0,430.6,1.89,,,54.0,14.04,39.6,13.38,33.64,0.0061354800000000004,-0.09183240000000001,43.3,1.3225473743033545,14.045828715283726,1.3796035143632456e-12,0.1259855781463273,303.46953531732237,-3.2285201957569085,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BTD-HV,SEG Solar Inc,Mono-c-Si,1,450.0,429.7,1.89,,,18.0,14.04,39.6,13.38,33.64,0.0055879200000000006,-0.0929412,43.5,1.3331725101945306,14.045527544547271,1.7520040739387924e-12,0.12413541290110477,315.3047766731557,-2.4020709841422465,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-450-BTE-BG,SEG Solar Inc,Mono-c-Si,1,450.0,428.5,1.93,,,16.0,15.9,35.82,15.12,29.78,0.008745000000000001,-0.08500086000000001,43.2,1.2436696029076977,15.907856972981133,4.893993962792692e-12,0.1402758584900043,283.8734665741458,3.796114536240688,-0.2901,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-455-BMA-BG,SEG Solar Inc,Mono-c-Si,0,455.0,427.5,2.15,,,72.0,11.49,50.3,10.84,42.0,0.00397554,-0.1298243,43.3,1.8301231343112714,11.4900068799616,1.330311620498248e-11,0.23753817690093795,396707.42108739784,6.562335819328681,-0.3496,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-455-BMB-BG,SEG Solar Inc,Mono-c-Si,1,455.0,428.5,2.16,,,60.0,13.86,41.42,13.24,34.39,0.00573804,-0.10636655999999999,43.3,1.4991488292170154,13.860005904107716,1.388779076291832e-11,0.1791460230859492,420552.9403965176,5.762764598163955,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-455-BMB-HV,SEG Solar Inc,Mono-c-Si,0,455.0,430.7,2.16,,,60.0,13.86,41.42,13.24,34.39,0.0065142,-0.099408,43.1,1.4605001503993313,13.861131587827806,6.676854814950537e-12,0.185650989486844,2273.9044335946583,6.567029497631078,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-455-BMB-TB,SEG Solar Inc,Mono-c-Si,0,455.0,426.6,2.16,,,60.0,13.86,41.42,13.24,34.39,0.00510048,-0.10860324,43.4,1.53188299249409,13.860002376733025,2.5063351402063122e-11,0.17147232618845912,999993.853019703,8.717126913956518,-0.3584,N,2025.7.3,6/23/2025,2.0,bootstrapping +SEG Solar Inc SEG-455-BTD-BG,SEG Solar Inc,Mono-c-Si,1,455.0,435.5,1.89,,,54.0,14.11,39.76,13.46,33.8,0.006166070000000001,-0.09220344,43.3,1.3277444804903749,14.115063834271155,1.3834095841210112e-12,0.12391371525277758,345.27641111916336,-3.2507955564975144,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-455-BTD-HV,SEG Solar Inc,Mono-c-Si,1,455.0,434.5,1.89,,,18.0,14.11,39.76,13.46,33.8,0.005615780000000001,-0.09331672,43.5,1.3384095246907008,14.114775267196519,1.756812624965051e-12,0.12206713933914642,360.6850506309466,-2.4245783945743944,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-455-BTE-BG,SEG Solar Inc,Mono-c-Si,1,455.0,433.3,1.93,,,16.0,15.96,36.0,15.19,29.96,0.008778000000000001,-0.085428,43.2,1.2500441962793027,15.966821201016801,4.9310627927582524e-12,0.13818929164676202,323.33031915902257,3.8251282743284807,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-460-BMA-BG,SEG Solar Inc,Mono-c-Si,0,460.0,432.3,2.15,,,72.0,11.57,50.5,10.91,42.2,0.00400322,-0.1303405,43.3,1.8376148180028467,11.570006497525997,1.3438862803459939e-11,0.23350076190423877,415792.2111362108,6.590131859734544,-0.3496,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-460-BMB-BG,SEG Solar Inc,Mono-c-Si,1,460.0,433.3,2.16,,,60.0,13.96,41.52,13.34,34.49,0.00577944,-0.10662335999999999,43.3,1.5032822820589309,13.960002457555195,1.4120832834597958e-11,0.17603832147679552,999999.585644867,5.844122701243965,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-460-BMB-HV,SEG Solar Inc,Mono-c-Si,0,460.0,435.5,2.16,,,60.0,13.96,41.52,13.34,34.49,0.0065612,-0.099648,43.1,1.4641494231998133,13.960814897700248,6.743416783378306e-12,0.18332236173574734,3140.4931633615456,6.589542916277652,-0.3124,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-460-BMB-TB,SEG Solar Inc,Mono-c-Si,0,460.0,431.4,2.16,,,60.0,13.96,41.52,13.34,34.49,0.00513728,-0.10886544,43.4,1.5361198104306097,13.960002350569495,2.5484558589876266e-11,0.16837224893279373,999999.8542891128,8.800535460373178,-0.3584,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-460-BTD-HV,SEG Solar Inc,Mono-c-Si,1,460.0,439.4,1.89,,,18.0,14.18,39.94,13.52,34.02,0.005643640000000001,-0.09373917999999999,43.5,1.3459729226920991,14.185019959406134,1.823766588762751e-12,0.11638785665202095,328.76357669008775,-2.157045472303703,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-460-BTE-BG,SEG Solar Inc,Mono-c-Si,1,460.0,438.2,1.93,,,16.0,16.03,36.2,15.26,30.14,0.008816500000000001,-0.08590260000000001,43.2,1.2571319448469949,16.03657501091638,4.970022660871312e-12,0.1373431660101391,334.8452173051169,3.854293471175472,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-465-BMB-TB,SEG Solar Inc,Mono-c-Si,0,465.0,434.0,2.16,,,60.0,14.06,41.62,13.44,34.6,0.002327633,-0.10174008999999999,43.6,1.5499330526948085,14.060002282765558,3.061773699591246e-11,0.1623514912084133,999999.8230383369,18.679381341177177,-0.38205,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-465-BTE-BG,SEG Solar Inc,Mono-c-Si,1,465.0,443.1,1.93,,,16.0,16.09,36.4,15.33,30.34,0.008849500000000001,-0.0863772,43.2,1.2642634876160481,16.095582271299385,5.014208579180357e-12,0.1351174756586407,389.454413381146,3.894863383893019,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-470-BMB-TB,SEG Solar Inc,Mono-c-Si,0,470.0,438.8,2.16,,,60.0,14.16,41.72,13.55,34.7,0.002344188,-0.10198454,43.6,1.554670867117494,14.160002226947176,3.138021010247029e-11,0.15726314377063222,999999.6076118572,18.846783362078337,-0.38205,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-470-BTB-BG,SEG Solar Inc,Mono-c-Si,1,470.0,442.2,2.15,,,60.0,13.88,42.8,13.21,35.6,0.006537480000000001,-0.0983116,43.6,1.5598282569728292,13.883661104843833,1.6747303265555102e-11,0.17801211366985806,674.8804674823498,20.07044897792233,-0.3414,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-475-BMB-TB,SEG Solar Inc,Mono-c-Si,0,475.0,443.6,2.16,,,60.0,14.26,41.83,13.65,34.8,0.002360743,-0.102253435,43.6,1.5591376222392155,14.26000221055344,3.180243903305405e-11,0.15501071340357178,999999.5069945642,18.90733466838866,-0.38205,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-475-BTB-BG,SEG Solar Inc,Mono-c-Si,1,475.0,447.0,2.15,,,60.0,13.94,43.0,13.27,35.8,0.0065657400000000005,-0.098771,43.6,1.567666534637284,13.943476003387842,1.6985004085038144e-11,0.17518281815246473,702.5449222459569,20.16533395216184,-0.3414,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-480-BTB-BG,SEG Solar Inc,Mono-c-Si,1,480.0,452.3,2.15,,,60.0,14.0,43.2,13.34,36.0,0.005782000000000001,-0.09590400000000002,43.5,1.5579433373840987,14.00304498105481,1.2649216739824533e-11,0.17525865630560214,805.7919532711772,21.446538827817168,-0.3379,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-485-BTB-BG,SEG Solar Inc,Mono-c-Si,1,485.0,457.1,2.15,,,60.0,14.08,43.4,13.4,36.2,0.0058150400000000005,-0.096348,43.5,1.566685704795071,14.084255456783984,1.3050986893324637e-11,0.1721738129702658,569.6702872085646,21.706710877714098,-0.3379,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-485-BTB-HV,SEG Solar Inc,Mono-c-Si,1,485.0,462.8,2.1,,,20.0,13.91,43.47,13.16,36.85,0.00553618,-0.10202408999999998,43.5,1.4667921415947665,13.921205059813648,1.841654165220963e-12,0.14361970807090027,178.290002335047,-1.8861038066065574,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-490-BTB-BG,SEG Solar Inc,Mono-c-Si,1,490.0,462.0,2.15,,,60.0,14.14,43.6,13.46,36.4,0.005839820000000001,-0.096792,43.5,1.5744303786804683,14.144064860675535,1.3230399265083902e-11,0.16942886037472793,589.3742262931745,21.79920198983818,-0.3379,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-490-BTB-HV,SEG Solar Inc,Mono-c-Si,1,490.0,467.7,2.1,,,20.0,13.95,43.64,13.23,37.03,0.0055521,-0.10242308,43.5,1.471582842589656,13.959221609727225,1.8170980555861828e-12,0.1408839392594725,213.12233027368637,-2.0301289829121947,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-495-BTB-BG,SEG Solar Inc,Mono-c-Si,1,495.0,473.6,2.1,,,60.0,14.0,43.82,13.31,37.2,0.006118000000000001,-0.10161858,43.3,1.4645803750824484,14.007683292664558,1.4029932870120226e-12,0.14174211924667487,258.27334153721915,-3.0581606548250306,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-495-BTB-HV,SEG Solar Inc,Mono-c-Si,1,495.0,472.5,2.1,,,20.0,14.0,43.82,13.31,37.2,0.0055720000000000006,-0.10284554,43.5,1.4763560739463497,14.007353845142589,1.7817267983276994e-12,0.13968064755610343,265.9192612149859,-2.2309071103428724,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-495-BTD-BG,SEG Solar Inc,Mono-c-Si,1,495.0,471.1,2.16,,,18.0,15.82,39.9,14.96,33.1,0.008701,-0.09468270000000001,43.2,1.3873545660371833,15.834916941940609,5.0466845697330885e-12,0.16242527186081573,172.25834998271688,4.127360114381358,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-500-BTB-BG,SEG Solar Inc,Mono-c-Si,1,500.0,478.5,2.1,,,60.0,14.04,44.0,13.38,37.38,0.0061354800000000004,-0.102036,43.3,1.4695366187422534,14.045823765887782,1.3807084867168611e-12,0.13979667037564492,337.02337829431355,-3.2220039291314366,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-500-BTB-HV,SEG Solar Inc,Mono-c-Si,1,500.0,477.4,2.1,,,20.0,14.04,44.0,13.38,37.38,0.0055879200000000006,-0.103268,43.5,1.4813428936197115,14.045522870197914,1.7534048181533919e-12,0.13774074690237534,350.1585260711162,-2.395542200351322,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-500-BTD-BG,SEG Solar Inc,Mono-c-Si,1,500.0,476.0,2.16,,,18.0,15.88,40.1,15.02,33.3,0.008734000000000002,-0.09515730000000001,43.2,1.394851770364447,15.89455231759125,5.1236733173569885e-12,0.1600396514815053,174.64088544928313,4.224530669500673,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-505-BMA-BG,SEG Solar Inc,Mono-c-Si,0,505.0,467.3,2.58,,,72.0,13.1,48.81,12.72,39.74,0.0062487,-0.13510608000000002,46.35,1.8303944686535458,13.100002668098416,3.437215506571255e-11,0.20360532399274142,999716.8405666093,5.956833261356541,-0.3595,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-505-BMA-HV,SEG Solar Inc,Mono-c-Si,0,505.0,466.9,2.58,,,72.0,13.1,48.81,12.72,39.74,0.007178800000000001,-0.13344654,46.16,1.8570874748393358,13.100196894777111,5.0414041645140426e-11,0.19505135985477692,12977.327056777996,10.567972499342263,-0.3666,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-505-BMA-TB,SEG Solar Inc,Mono-c-Si,0,505.0,473.1,2.58,,,72.0,13.1,48.81,12.72,39.74,0.005279300000000001,-0.12895602,43.1,1.8111197688477774,13.100002738333043,2.5879519694543018e-11,0.2089699599590939,999731.5310434472,8.618696514419165,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-505-BTB-BG,SEG Solar Inc,Mono-c-Si,1,505.0,483.3,2.1,,,60.0,14.11,44.18,13.45,37.55,0.006166070000000001,-0.10245342,43.3,1.4756939122888963,14.11563196306597,1.3920384432116426e-12,0.13825772729564936,346.3830481737009,-3.1970084984062823,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-505-BTB-HV,SEG Solar Inc,Mono-c-Si,1,505.0,482.3,2.1,,,20.0,14.11,44.18,13.45,37.55,0.005615780000000001,-0.10369046,43.5,1.48755032378688,14.115334355636492,1.7677750259090084e-12,0.13620328144603464,360.2737489708877,-2.3705452633770148,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-505-BTD-BG,SEG Solar Inc,Mono-c-Si,1,505.0,480.9,2.16,,,18.0,15.95,40.3,15.08,33.5,0.0087725,-0.09563189999999999,43.2,1.4027423913943988,15.964967851550822,5.2426748591519755e-12,0.15756206141260687,167.90084237526068,4.3866755764052465,-0.2901,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-510-BMA-BG,SEG Solar Inc,Mono-c-Si,0,510.0,472.0,2.58,,,72.0,13.2,48.9,12.76,40.0,0.006296400000000001,-0.13535519999999998,46.35,1.8338500578925097,13.20000275535534,3.467513151468095e-11,0.20866410858481377,999684.9340596799,5.966876438693248,-0.3595,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-510-BMA-HV,SEG Solar Inc,Mono-c-Si,0,510.0,471.6,2.58,,,72.0,13.2,48.9,12.76,40.0,0.007233600000000001,-0.1336926,46.16,1.8601667903585286,13.20000296100649,5.056546166722591e-11,0.2016477413753818,898475.6608922023,10.52579540172205,-0.3666,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-510-BMA-TB,SEG Solar Inc,Mono-c-Si,0,510.0,477.9,2.58,,,72.0,13.2,48.9,12.76,40.0,0.005319600000000001,-0.1291938,43.1,1.814601489521779,13.200002823037861,2.6132214910176445e-11,0.21379497556386295,999700.1140182284,8.637268192485706,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-510-BTB-HV,SEG Solar Inc,Mono-c-Si,1,510.0,487.2,2.1,,,20.0,14.17,44.38,13.51,37.75,0.00563966,-0.10415986,43.5,1.494688250704857,14.175145251056488,1.7899091384554838e-12,0.13374934116749637,368.34512949064737,-2.304422773331766,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-510-BTD-BG,SEG Solar Inc,Mono-c-Si,1,510.0,485.7,2.16,,,18.0,16.01,40.5,15.14,33.7,0.0088055,-0.09610650000000001,43.2,1.4102383523091895,16.02460247856413,5.3208547464806355e-12,0.15521551092760502,170.17660904456844,4.481394877777711,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-515-BMA-BG,SEG Solar Inc,Mono-c-Si,0,515.0,476.8,2.58,,,72.0,13.3,49.01,12.8,40.26,0.0063441,-0.13565967999999998,46.35,1.8330738650128287,13.300006055369598,3.2533410712362735e-11,0.24741462880192078,543435.5851182152,5.357155795121452,-0.3595,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-515-BMA-HV,SEG Solar Inc,Mono-c-Si,0,515.0,476.4,2.58,,,72.0,13.3,49.01,12.8,40.26,0.0072884000000000004,-0.13399334,46.16,1.8238160196457942,13.300006093844043,2.840459076327981e-11,0.24897271912676266,543403.564709284,5.416758513346761,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-515-BMA-TB,SEG Solar Inc,Mono-c-Si,0,515.0,482.7,2.58,,,72.0,13.3,49.01,12.8,40.26,0.005359900000000001,-0.12948442,43.1,1.791111161325111,13.300006230134134,1.7389670465262755e-11,0.2545017472521193,543315.1593107239,5.045301136448539,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-515-BTC-BG,SEG Solar Inc,Mono-c-Si,1,515.0,492.2,2.3,,,66.0,13.74,47.03,12.95,39.77,0.00600438,-0.10906257,43.3,1.5751221005500138,13.754990722731396,1.4505462441173707e-12,0.16781419767536293,153.8129360544102,-2.5962751945541247,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-515-BTD-BG,SEG Solar Inc,Mono-c-Si,1,515.0,490.6,2.16,,,18.0,16.07,40.7,15.2,33.9,0.008838500000000001,-0.09658110000000002,43.2,1.4177331343376287,16.084243426893405,5.39937090735628e-12,0.15288808747472565,172.49439367681916,4.574982466096323,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-520-BMA-BG,SEG Solar Inc,Mono-c-Si,0,520.0,481.6,2.58,,,72.0,13.41,49.1,12.84,40.52,0.00639657,-0.1359088,46.35,1.8407052482140605,13.410002889669983,3.489905571815278e-11,0.21547574265503885,999997.462464158,5.8867612976343136,-0.3595,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-520-BMA-HV,SEG Solar Inc,Mono-c-Si,0,520.0,481.2,2.58,,,72.0,13.41,49.1,12.84,40.52,0.00734868,-0.1342394,46.16,1.8167496118549142,13.41000590751632,2.4550356582568614e-11,0.23366862148053938,530435.4815683176,4.106671214141285,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-520-BMA-TB,SEG Solar Inc,Mono-c-Si,0,520.0,487.5,2.58,,,72.0,13.41,49.1,12.84,40.52,0.00540423,-0.1297222,43.1,1.821562408434423,13.410092808181306,2.636501077327004e-11,0.23285526843626803,33645.66720268579,8.576863189386616,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-520-BTC-BG,SEG Solar Inc,Mono-c-Si,1,520.0,497.1,2.3,,,66.0,13.79,47.22,13.01,39.97,0.0060262300000000005,-0.10950318,43.3,1.5815014829655962,13.804001565638996,1.4578202604162877e-12,0.16453549711757232,162.04934251705507,-2.5892086171192656,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-520-BTD-BG,SEG Solar Inc,Mono-c-Si,1,520.0,495.5,2.16,,,18.0,16.13,40.9,15.25,34.1,0.0088715,-0.0970557,43.2,1.425647651796531,16.144657108584624,5.520601790569861e-12,0.1505604635289629,165.69027014341881,4.736964249300223,-0.2901,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-525-BMA-BG,SEG Solar Inc,Mono-c-Si,0,525.0,486.3,2.58,,,72.0,13.5,49.2,12.88,40.78,0.0064395,-0.13618560000000002,46.35,1.8450722346196304,13.500002867548236,3.544863343933722e-11,0.2124009553976905,999999.8641694889,5.963352969327265,-0.3595,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-525-BMA-HV,SEG Solar Inc,Mono-c-Si,0,525.0,485.9,2.58,,,72.0,13.5,49.2,12.88,40.78,0.007398000000000001,-0.1345128,46.16,1.8715118706088836,13.50000278221686,5.1666064480685863e-11,0.20607681696256985,999999.8629582124,10.517386362132976,-0.3666,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-525-BMA-TB,SEG Solar Inc,Mono-c-Si,0,525.0,492.3,2.58,,,72.0,13.5,49.2,12.88,40.78,0.005440500000000001,-0.1299864,43.1,1.8258853241159516,13.500069460944024,2.6783794073984184e-11,0.2167899018876167,42133.99331060414,8.656523758255993,-0.359,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-525-BTC-BG,SEG Solar Inc,Mono-c-Si,1,525.0,501.9,2.3,,,66.0,13.85,47.42,13.07,40.17,0.006052450000000001,-0.10996698,43.3,1.5885731542377224,13.86366582912144,1.474821179439511e-12,0.1618812286144695,164.06286052478205,-2.530928980680743,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-525-BTD-BG,SEG Solar Inc,Mono-c-Si,1,525.0,500.4,2.16,,,18.0,16.2,41.1,15.31,34.3,0.00891,-0.09753030000000001,43.2,1.433540738186379,16.21501765676804,5.644617260174038e-12,0.14815735551720816,159.82181510475337,4.893903627456292,-0.2901,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-530-BMA-BG,SEG Solar Inc,Mono-c-Si,0,530.0,491.1,2.58,,,72.0,13.6,49.33,12.92,41.03,0.0064872,-0.13654544,46.35,1.8544153041364164,13.631583948009109,3.657130603469284e-11,0.20072675338660195,86.43263471874235,59.52324835029622,-0.3595,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-530-BMA-HV,SEG Solar Inc,Mono-c-Si,0,530.0,490.7,2.58,,,72.0,13.6,49.33,12.92,41.03,0.007452800000000001,-0.13486821999999998,46.16,1.882074681171099,13.603302899862102,5.605747920101239e-11,0.19532305750298964,804.2610929673689,11.198388121013197,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-530-BMA-TB,SEG Solar Inc,Mono-c-Si,0,530.0,497.1,2.58,,,72.0,13.6,49.33,12.92,41.03,0.005480800000000001,-0.13032986,43.1,1.8376264469563977,13.604370036414666,2.970278932703921e-11,0.20286498222933325,631.3365717160218,9.525310104860536,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-530-BTC-BG,SEG Solar Inc,Mono-c-Si,1,530.0,506.8,2.3,,,66.0,13.91,47.62,13.13,40.35,0.00607867,-0.11043077999999999,43.3,1.5952817122393212,13.923459202915586,1.4818581211555966e-12,0.16097251157817044,166.36405965069466,-2.528429471924992,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-535-BMA-BG,SEG Solar Inc,Mono-c-Si,0,535.0,495.9,2.58,,,72.0,13.7,49.4,12.96,41.29,0.006534899999999999,-0.1367392,46.35,1.8676338550032672,13.707455124124035,4.414312838616465e-11,0.18019477635982642,331.13713940329575,7.77005352909852,-0.3595,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-535-BMA-HV,SEG Solar Inc,Mono-c-Si,0,535.0,495.4,2.58,,,72.0,13.7,49.4,12.96,41.29,0.0075076,-0.13505959999999997,46.16,1.8934407825207824,13.706807740614424,6.334568045897393e-11,0.17581809538832577,353.8189993596084,12.256582684550185,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-535-BMA-TB,SEG Solar Inc,Mono-c-Si,0,535.0,501.9,2.58,,,72.0,13.7,49.4,12.96,41.29,0.005521099999999999,-0.1305148,43.1,1.848562951565013,13.707949464902462,3.358472919086292e-11,0.18344370520117584,316.144493267202,10.574475487993222,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-535-BTC-BG,SEG Solar Inc,Mono-c-Si,1,535.0,511.7,2.3,,,66.0,13.95,47.81,13.2,40.54,0.00609615,-0.11087139,43.3,1.60042763453229,13.96144386621115,1.4567571987925301e-12,0.15885870533303303,193.64775020668515,-2.7019893200783325,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-535-BTC-HV,SEG Solar Inc,Mono-c-Si,1,535.0,510.6,2.3,,,22.0,13.95,47.81,13.2,40.54,0.0055521,-0.11221007,43.5,1.613317276193592,13.96105840679407,1.8500478108054524e-12,0.15658278313661358,197.5266298920711,-1.8730496326750765,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-540-BMA-BG,SEG Solar Inc,Mono-c-Si,0,540.0,500.6,2.58,,,72.0,13.81,49.5,13.0,41.55,0.0065873699999999995,-0.137016,46.35,1.8801318861078415,13.82082215673639,4.999295762809776e-11,0.1629423871259359,207.92846042974816,8.8119031987322,-0.3595,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-540-BMA-HV,SEG Solar Inc,Mono-c-Si,0,540.0,500.2,2.58,,,72.0,13.81,49.5,13.0,41.55,0.00756788,-0.13533299999999998,46.16,1.9061312295159603,13.820110654199018,7.163867415375933e-11,0.15852827188985738,216.53153471976995,13.328275687542398,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-540-BMA-TB,SEG Solar Inc,Mono-c-Si,0,540.0,506.7,2.58,,,72.0,13.81,49.5,13.0,41.55,0.0055654300000000006,-0.130779,43.1,1.8608000075606985,13.821367652140273,3.8011263206499545e-11,0.16623936623189606,201.95600962720982,11.638595980788411,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-540-BTC-BG,SEG Solar Inc,Mono-c-Si,1,540.0,516.6,2.3,,,66.0,13.97,48.01,13.26,40.73,0.006104890000000001,-0.11133518999999999,43.3,1.605282817243669,13.978989183506549,1.414774469638599e-12,0.157798065800627,245.23239275338761,-2.96561371586715,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-540-BTC-HV,SEG Solar Inc,Mono-c-Si,1,540.0,515.4,2.3,,,22.0,13.97,48.01,13.26,40.73,0.005560060000000001,-0.11267946999999999,43.5,1.61819595499952,13.97863968701034,1.796712234679829e-12,0.15552915172910575,251.48390776601974,-2.1378507618067277,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-545-BMA-BG,SEG Solar Inc,Mono-c-Si,0,545.0,505.4,2.58,,,72.0,13.91,49.6,13.04,41.81,0.00663507,-0.13729280000000002,46.35,1.8920361102744099,13.9228472089382,5.607055120178483e-11,0.14598130959511543,158.05767972890385,9.78062492748096,-0.3595,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-545-BMA-HV,SEG Solar Inc,Mono-c-Si,0,545.0,505.0,2.58,,,72.0,13.91,49.6,13.04,41.81,0.007622680000000001,-0.13560640000000002,46.16,1.918213301854649,13.922084310517032,8.023750719449516e-11,0.14153305690484294,162.9157776584934,14.3242115524402,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-545-BMA-TB,SEG Solar Inc,Mono-c-Si,0,545.0,511.5,2.58,,,72.0,13.91,49.6,13.04,41.81,0.005605730000000001,-0.1310432,43.1,1.8724607936610367,13.9234346351226,4.260950536753e-11,0.14932276987906587,154.60633843701197,12.628271799483798,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-545-BTC-BG,SEG Solar Inc,Mono-c-Si,1,545.0,521.5,2.3,,,66.0,14.01,48.2,13.32,40.92,0.00612237,-0.11177580000000001,43.3,1.6109756759053875,14.017655595850679,1.4041579859190694e-12,0.1556576889054642,284.8588490336265,-3.0573744369038858,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-545-BTC-HV,SEG Solar Inc,Mono-c-Si,1,545.0,520.3,2.3,,,22.0,14.01,48.2,13.32,40.92,0.00557598,-0.1131254,43.5,1.623928422966575,14.017326509306505,1.7832042723520801e-12,0.15339181728967893,293.3210444088897,-2.2301266837807217,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-550-BMA-BG,SEG Solar Inc,Mono-c-Si,0,550.0,510.2,2.58,,,72.0,14.01,49.7,13.08,42.07,0.00668277,-0.13756960000000001,46.35,1.9040184016683408,14.02414890673793,6.286558057823842e-11,0.12910108198574885,127.83363441880552,10.754731983567735,-0.3595,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-550-BMA-HV,SEG Solar Inc,Mono-c-Si,0,550.0,509.8,2.58,,,72.0,14.01,49.7,13.08,42.07,0.00767748,-0.1358798,46.16,1.9303696349801975,14.02333251661829,8.983208723491737e-11,0.12461944924731241,130.9519089445307,15.325085917843616,-0.3666,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-550-BMA-TB,SEG Solar Inc,Mono-c-Si,0,550.0,516.4,2.58,,,72.0,14.01,49.7,13.08,42.07,0.005646030000000001,-0.13130740000000002,43.1,1.8842008183006698,14.024780288329831,4.7750609021945767e-11,0.13248677087780755,125.58210156525878,13.623841049675594,-0.359,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-550-BTC-BG,SEG Solar Inc,Mono-c-Si,1,550.0,526.4,2.3,,,66.0,14.05,48.4,13.38,41.11,0.006139850000000001,-0.1122396,43.3,1.61685266614031,14.056380619591227,1.3898700026754483e-12,0.15428419703065877,339.7307955999433,-3.1709216775976765,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-555-BMA-TB,SEG Solar Inc,Mono-c-Si,0,555.0,523.0,2.58,,,72.0,14.1,49.8,13.12,42.31,0.0025938359999999995,-0.11413662000000001,43.3,1.791395971751846,14.118942859677482,1.1512335128746142e-11,0.13560177547103197,100.93433984415438,17.094405387062,-0.33585,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-555-BTC-BG,SEG Solar Inc,Mono-c-Si,1,555.0,531.2,2.3,,,66.0,14.11,48.6,13.45,41.26,0.006166070000000001,-0.11270340000000001,43.3,1.6224996029388457,14.115721357648846,1.3709978242315935e-12,0.15600537661411767,384.7401266270987,-3.3209346567737854,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-555-BTC-HV,SEG Solar Inc,Mono-c-Si,1,555.0,530.1,2.3,,,22.0,14.11,48.6,13.45,41.26,0.005615780000000001,-0.1140642,43.5,1.6355302643363032,14.115418485008872,1.7411025877524676e-12,0.15374924403065368,400.3705523859628,-2.4947102561270995,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-560-BMA-TB,SEG Solar Inc,Mono-c-Si,0,560.0,527.8,2.58,,,72.0,14.21,49.9,13.16,42.56,0.0026140716,-0.11436581,43.3,1.8026673124873858,14.22973674585746,1.2982968278020796e-11,0.11977840798788864,86.23768029219727,18.19431525024483,-0.33585,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-560-BTA-BG,SEG Solar Inc,Mono-c-Si,1,560.0,526.9,2.56,,,72.0,13.86,51.3,13.6,42.56,0.005391539999999999,-0.13148189999999998,43.4,1.8888615453656812,13.860001359860368,2.2215883428626256e-11,0.09039752781957694,920663.0418895015,10.12486496731074,-0.3444,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-560-BTC-HV,SEG Solar Inc,Mono-c-Si,1,560.0,535.0,2.3,,,22.0,14.15,48.81,13.5,41.48,0.005631700000000001,-0.11455707000000001,43.5,1.6427121535612619,14.154707962476575,1.751306049779673e-12,0.15056081845294167,452.5175369847928,-2.473920629218619,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-565-BMA-TB,SEG Solar Inc,Mono-c-Si,0,565.0,532.7,2.58,,,72.0,14.3,50.0,13.2,42.81,0.0026306280000000003,-0.114595,43.3,1.8127460205593233,14.319085991182773,1.4360777741174405e-11,0.1044385213604444,78.24958329857004,19.12271898420849,-0.33585,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-565-BTA-BG,SEG Solar Inc,Mono-c-Si,1,565.0,531.8,2.56,,,72.0,13.89,51.5,13.21,42.8,0.0054032099999999994,-0.1319945,43.4,1.8797121443929303,13.89430012603416,1.74506606408145e-11,0.2166632347547756,699.8521295888269,7.990334037093068,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-570-BMA-TB,SEG Solar Inc,Mono-c-Si,0,570.0,537.5,2.58,,,72.0,14.4,50.0,13.24,43.07,0.0026490240000000003,-0.114595,43.3,1.8219413130519042,14.416499536594417,1.653566913341418e-11,0.08050921374155562,70.26456004847543,20.446620981593405,-0.33585,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-570-BTA-BG,SEG Solar Inc,Mono-c-Si,1,570.0,536.6,2.56,,,72.0,13.95,51.7,13.26,43.0,0.005426549999999999,-0.1325071,43.4,1.8803417103641242,13.95010065355888,1.5980686195290306e-11,0.2148214027762183,29773.016575148533,7.164661673255109,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-575-BTA-BG,SEG Solar Inc,Mono-c-Si,1,575.0,541.4,2.56,,,72.0,14.01,51.9,13.32,43.2,0.00544989,-0.1330197,43.4,1.8960509057123756,14.014644583038269,1.8040075701808157e-11,0.21064323663368406,635.3879062240717,8.208367954186023,-0.3444,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-580-BTA-BG,SEG Solar Inc,Mono-c-Si,1,580.0,546.4,2.56,,,72.0,13.84,51.95,13.17,44.02,0.007695039999999999,-0.11808235000000002,43.5,1.9208309574164657,13.843304433144361,2.4705430130828895e-11,0.14465888470941388,605.876681966639,25.173776445672537,-0.3407,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-580-BTA-HV,SEG Solar Inc,Mono-c-Si,1,580.0,553.4,2.51,,,24.0,13.84,51.95,13.17,44.02,0.00550832,-0.12192665000000001,43.5,1.7480721383011193,13.846774823316292,1.6990112559891036e-12,0.17460692534661457,356.6971027692181,-2.529362998673364,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-585-BMZ-BG,SEG Solar Inc,Mono-c-Si,1,585.0,548.9,2.77,,,78.0,13.88,53.2,13.13,44.56,0.004825243200000001,-0.1312444,43.6,1.9569742088156061,13.888739359191359,2.142783658939198e-11,0.1928578292716803,306.30011280086626,14.192643896171722,-0.35066,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-585-BTA-BG,SEG Solar Inc,Mono-c-Si,1,585.0,559.6,2.51,,,72.0,13.89,52.16,13.23,44.22,0.00606993,-0.12095903999999999,43.3,1.7408315914395465,13.896342874202725,1.33660304740086e-12,0.17533456232713357,383.95796518436475,-3.3964269900543114,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-585-BTA-HV,SEG Solar Inc,Mono-c-Si,1,585.0,558.3,2.51,,,24.0,13.89,52.16,13.23,44.22,0.00552822,-0.12241951999999999,43.5,1.754810330865514,13.8960298726908,1.6974781271457393e-12,0.1728760206297397,398.22531128817684,-2.5701912216390093,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-590-BMZ-BG,SEG Solar Inc,Mono-c-Si,1,590.0,553.8,2.77,,,78.0,13.93,53.3,13.17,44.8,0.004842625200000001,-0.1314911,43.6,1.9645639824999541,13.938777608533341,2.2678834456803916e-11,0.17887688286242914,283.87629704206097,14.689378781561611,-0.35066,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-590-BTA-BG,SEG Solar Inc,Mono-c-Si,1,590.0,564.4,2.51,,,72.0,13.94,52.37,13.28,44.43,0.006091780000000001,-0.12144602999999998,43.3,1.7482731019950768,13.946164969649763,1.3516002366255895e-12,0.17270764525187152,390.5201020624521,-3.335689861766856,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-590-BTA-HV,SEG Solar Inc,Mono-c-Si,1,590.0,563.2,2.51,,,24.0,13.94,52.37,13.28,44.43,0.00554812,-0.12291238999999998,43.5,1.762314082816237,13.94585610469696,1.7164946366104e-12,0.17024631382739452,405.2580581014242,-2.5093761820943805,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-595-BMZ-BG,SEG Solar Inc,Mono-c-Si,1,595.0,558.6,2.77,,,78.0,13.98,53.4,13.21,45.05,0.0048600072000000005,-0.13173780000000002,43.6,1.9723732179905793,13.988675123257535,2.4064717616030597e-11,0.16411740091390417,264.4759221877011,15.212266990225055,-0.35066,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-595-BTA-BG,SEG Solar Inc,Mono-c-Si,1,595.0,569.3,2.51,,,72.0,13.99,52.58,13.33,44.64,0.00611363,-0.12193302,43.3,1.7557140202026142,13.995990400934952,1.3666471925179826e-12,0.17010083432511522,397.2539901968808,-3.275518512077664,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-595-BTA-HV,SEG Solar Inc,Mono-c-Si,1,595.0,568.1,2.51,,,24.0,13.99,52.58,13.33,44.64,0.00556802,-0.12340526,43.5,1.7698172491626443,13.99568565677337,1.7355743836711915e-12,0.16763673429317566,412.4832026235584,-2.449125602086143,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-600-BMZ-BG,SEG Solar Inc,Mono-c-Si,1,600.0,563.4,2.77,,,78.0,14.03,53.5,13.25,45.3,0.004877389200000001,-0.1319845,43.6,1.9801846970839958,14.038460875871941,2.5524605560310842e-11,0.14945126486081906,247.82319160883077,15.733511404561623,-0.35066,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-600-BTA-BG,SEG Solar Inc,Mono-c-Si,1,600.0,574.2,2.51,,,72.0,14.04,52.8,13.38,44.85,0.0061354800000000004,-0.1224432,43.3,1.763337193541536,14.045834890001894,1.3782234307894758e-12,0.16826173115049722,404.8739062108035,-3.2366656945614074,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-600-BTA-HV,SEG Solar Inc,Mono-c-Si,1,600.0,572.9,2.51,,,24.0,14.04,52.8,13.38,44.85,0.0055879200000000006,-0.1239216,43.5,1.7775031894336104,14.045533375410058,1.7502545900931785e-12,0.16579512061273352,420.6769509965003,-2.4102322069429034,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-600-BTC-BG,SEG Solar Inc,Mono-c-Si,1,600.0,565.8,2.68,,,66.0,15.95,47.4,15.21,39.44,0.007113700000000001,-0.10134119999999999,43.3,1.708366232455611,15.952498769023201,1.4184338316047058e-11,0.1732123824080577,1105.6394316437343,25.927387831056507,-0.3378,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-605-BMZ-BG,SEG Solar Inc,Mono-c-Si,1,605.0,568.2,2.77,,,78.0,14.08,53.61,13.29,45.53,0.004894771200000001,-0.13225587,43.6,1.9877509659929369,14.088262007397072,2.6837331287768783e-11,0.1373565966608581,234.08123455186725,16.17454899802463,-0.35066,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-605-BTA-BG,SEG Solar Inc,Mono-c-Si,1,605.0,579.1,2.51,,,72.0,14.11,53.0,13.45,45.01,0.006166070000000001,-0.122907,43.3,1.7696509629461334,14.115696186815756,1.3769701585130371e-12,0.16891124151670786,418.40931433881246,-3.285579116717556,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-605-BTA-HV,SEG Solar Inc,Mono-c-Si,1,605.0,577.8,2.51,,,24.0,14.11,53.0,13.45,45.01,0.005615780000000001,-0.124391,43.5,1.783865060964915,14.115394819627175,1.7486734418360717e-12,0.16644965274240614,435.3444162740406,-2.459287269321321,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-605-BTC-BG,SEG Solar Inc,Mono-c-Si,1,605.0,570.6,2.68,,,66.0,16.0,47.9,15.28,39.6,0.007136,-0.10241019999999999,43.3,1.7201331121685097,16.000218742448027,1.2893586697479923e-11,0.1936767035900131,14166.503516404213,24.907898334855744,-0.3378,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-610-BMZ-BG,SEG Solar Inc,Mono-c-Si,1,610.0,573.0,2.77,,,78.0,14.13,53.7,13.33,45.76,0.004912153200000001,-0.1324779,43.6,1.9949464137638782,14.137898576096953,2.8348344155699623e-11,0.12382803012453038,221.51968139468548,16.660990493299057,-0.35066,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-610-BTA-BG,SEG Solar Inc,Mono-c-Si,1,610.0,584.0,2.51,,,72.0,14.17,53.2,13.51,45.16,0.0061922900000000005,-0.1233708,43.3,1.7758144366433335,14.175594379430581,1.3712598738725111e-12,0.17050532161111748,431.872817985004,-3.35477128157128,-0.2623,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-610-BTA-HV,SEG Solar Inc,Mono-c-Si,1,610.0,582.7,2.51,,,24.0,14.17,53.2,13.51,45.16,0.00563966,-0.1248604,43.5,1.7900745358157328,14.175291949278574,1.7414414588961687e-12,0.16804760689469,449.9730567028196,-2.5286511953134574,-0.2721,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-610-BTC-BG,SEG Solar Inc,Mono-c-Si,1,610.0,580.8,2.62,,,22.0,16.0,48.6,15.08,40.46,0.0088,-0.11532780000000002,43.2,1.6952420303555973,16.018492811301712,5.568526919411242e-12,0.18476475367961342,159.85866101337282,4.895026357758994,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-615-BTC-BG,SEG Solar Inc,Mono-c-Si,1,615.0,585.7,2.62,,,22.0,16.06,48.8,15.15,40.6,0.008832999999999999,-0.1158024,43.2,1.7010049956418956,16.0776424618516,5.482288864406493e-12,0.18685428512153932,170.0941653660837,4.723405390501656,-0.2901,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-620-BTC-BG,SEG Solar Inc,Mono-c-Si,1,620.0,590.5,2.62,,,22.0,16.13,49.0,15.22,40.74,0.0088715,-0.116277,43.2,1.7072482932006479,16.147536669050318,5.441216356662946e-12,0.18878993679616757,173.64652730699183,4.619445225228502,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-620-BTZ-BG,SEG Solar Inc,Mono-c-Si,1,620.0,585.0,2.76,,,78.0,13.74,56.82,13.09,47.37,0.00627918,-0.13318608,43.2,2.0606686445042706,13.74293345396861,1.4499979026346602e-11,0.23125198217738807,1083.160776214951,16.384469760686674,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-625-BTC-BG,SEG Solar Inc,Mono-c-Si,1,625.0,595.4,2.62,,,22.0,16.19,49.2,15.29,40.88,0.008904500000000001,-0.11675160000000001,43.2,1.713016052429296,16.20664268365235,5.358493121817771e-12,0.19084060340515163,185.64970883554795,4.451008133305671,-0.2901,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-625-BTZ-BG,SEG Solar Inc,Mono-c-Si,1,625.0,589.9,2.76,,,78.0,13.8,56.95,13.15,47.54,0.0063066,-0.1334908,43.2,2.0664639184199016,13.802771673458848,1.4776712655670973e-11,0.22543088387889332,1122.4072034406463,16.52188552865184,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-630-BTC-BG,SEG Solar Inc,Mono-c-Si,1,630.0,600.3,2.62,,,22.0,16.25,49.4,15.35,41.04,0.008937500000000001,-0.1172262,43.2,1.719688308669726,16.26645973796641,5.353689741150656e-12,0.19137281586041602,188.93425068327005,4.410370743706451,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-630-BTZ-BG,SEG Solar Inc,Mono-c-Si,1,630.0,594.7,2.76,,,78.0,13.86,57.08,13.21,47.7,0.00633402,-0.13379552,43.2,2.0720504241765556,13.862610202279638,1.5015782023415126e-11,0.2205288379287793,1170.9919497061276,16.63241914601262,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-635-BTC-BG,SEG Solar Inc,Mono-c-Si,1,635.0,605.2,2.62,,,22.0,16.31,49.6,15.42,41.18,0.0089705,-0.11770080000000002,43.2,1.7254596692757551,16.325533683851752,5.27359936612668e-12,0.19339344590650964,203.05853644035975,4.244631522104213,-0.2901,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-635-BTZ-BG,SEG Solar Inc,Mono-c-Si,1,635.0,599.6,2.76,,,78.0,13.92,57.21,13.27,47.86,0.0063614399999999995,-0.13410024,43.2,1.9631829727063126,13.924844823181687,3.0561156467498123e-12,0.2351238108497675,675.5506513163431,2.320673914590269,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-640-BTC-BG,SEG Solar Inc,Mono-c-Si,1,640.0,610.1,2.62,,,22.0,16.37,49.8,15.48,41.34,0.009003500000000001,-0.1181754,43.2,1.7321325157508096,16.38534302400268,5.269428197239865e-12,0.193911115164479,206.89043877093027,4.205231537986917,-0.2901,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-640-BTZ-BG,SEG Solar Inc,Mono-c-Si,1,640.0,604.4,2.76,,,78.0,13.98,57.34,13.33,48.02,0.00638886,-0.13440496,43.2,2.0832222138195267,13.982301589969396,1.550152405877727e-11,0.21085913446266288,1280.771467667864,16.85182189410698,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +SEG Solar Inc SEG-645-BTC-BG,SEG Solar Inc,Mono-c-Si,1,645.0,614.9,2.62,,,22.0,16.42,50.0,15.54,41.51,0.009031,-0.11865,43.2,1.738530847590743,16.43432350707241,5.241933335925467e-12,0.1938213259106947,222.19042941960538,4.13038219196813,-0.2901,N,2025.7.3,6/23/2025,2.0,first_pass +SEG Solar Inc SEG-695-BTC-BG,SEG Solar Inc,Mono-c-Si,1,695.0,656.6,3.08,,,66.0,18.44,47.7,17.47,39.8,0.0134612,-0.1158156,43.4,1.7626422703402922,18.449861959795655,3.227892891020888e-11,0.1387148800542728,259.37059859630136,16.71332531253382,-0.3268,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-700-BTC-BG,SEG Solar Inc,Mono-c-Si,1,700.0,669.8,3.03,,,22.0,18.33,48.57,17.3,40.47,0.014480699999999999,-0.11297382,43.4,1.6713076490494754,18.350156761920328,4.312154895305544e-12,0.16187218469166864,147.2020734400574,3.2601253083824413,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-705-BTC-BG,SEG Solar Inc,Mono-c-Si,1,705.0,674.7,3.03,,,22.0,18.39,48.73,17.36,40.63,0.0145281,-0.11334597999999999,43.4,1.6771895667609285,18.409796843405054,4.355294489250955e-12,0.16013180275731762,148.75219223220662,3.317165172955745,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-710-BHC-BG,SEG Solar Inc,Mono-c-Si,1,710.0,676.8,3.03,,,22.0,17.99,49.97,16.93,41.96,0.009480729999999998,-0.11633016,43.5,1.7231301402787649,18.011364444499563,4.481882415777388e-12,0.14854337993469285,125.08143645683819,4.071193477617734,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-710-BTC-BG,SEG Solar Inc,Mono-c-Si,1,710.0,679.6,3.03,,,22.0,18.45,48.87,17.42,40.76,0.0145755,-0.11367161999999999,43.4,1.6821225994944973,18.46952080895267,4.379011147094237e-12,0.15920806446444488,150.47474688023414,3.3351979652114885,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-715-BHC-BG,SEG Solar Inc,Mono-c-Si,1,715.0,681.7,3.03,,,22.0,18.08,50.07,17.02,42.05,0.009528159999999999,-0.11656296000000001,43.5,1.726451369152314,18.10106179111535,4.496274375697722e-12,0.14771319591261428,126.8009244615099,4.054273686016064,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-715-BTC-BG,SEG Solar Inc,Mono-c-Si,1,715.0,684.5,3.03,,,22.0,18.51,49.02,17.48,40.91,0.014622900000000001,-0.11402052,43.4,1.6876271136798286,18.52917917535461,4.419897190473433e-12,0.1575646191937634,152.06707537962225,3.3868186193719128,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-720-BHC-BG,SEG Solar Inc,Mono-c-Si,1,720.0,686.6,3.03,,,22.0,18.17,50.17,17.1,42.14,0.00957559,-0.11679576000000001,43.5,1.7302324214740878,18.191438797507242,4.5424236818923415e-12,0.1468611237533493,124.46904355592032,4.100801318361465,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-720-BTC-BG,SEG Solar Inc,Mono-c-Si,1,720.0,689.4,3.03,,,22.0,18.57,49.2,17.54,41.05,0.0146703,-0.11443920000000002,43.4,1.6934809377213018,18.589043983152386,4.4092856147545825e-12,0.15830018738951035,154.3602753403935,3.337346870179154,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-725-BHC-BG,SEG Solar Inc,Mono-c-Si,1,725.0,691.4,3.03,,,22.0,18.26,50.27,17.18,42.23,0.00962302,-0.11702856000000002,43.5,1.73401229362066,18.28181351089431,4.588749137899647e-12,0.1460171580835285,122.23036087924292,4.147194467425551,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-725-BTC-BG,SEG Solar Inc,Mono-c-Si,1,725.0,694.3,3.03,,,22.0,18.63,49.39,17.6,41.19,0.0147177,-0.11488114,43.4,1.6995164279060666,18.64895272501264,4.386701851492208e-12,0.15960195103129218,156.88426592929525,3.2642631191804834,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-730-BHC-BG,SEG Solar Inc,Mono-c-Si,1,730.0,696.3,3.03,,,22.0,18.35,50.37,17.26,42.32,0.00967045,-0.11726136000000001,43.5,1.7377914868306419,18.37218592920403,4.6352810578614e-12,0.14518131511101662,120.07958331840476,4.193069687672414,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-730-BTC-BG,SEG Solar Inc,Mono-c-Si,1,730.0,699.2,3.03,,,22.0,18.69,49.57,17.66,41.34,0.014765100000000001,-0.11529982000000001,43.4,1.7055653838019271,18.70875672750323,4.390943315813609e-12,0.15968164457259834,159.11357350875315,3.244112692404781,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-735-BHC-BG,SEG Solar Inc,Mono-c-Si,1,735.0,701.2,3.03,,,22.0,18.44,50.47,17.34,42.41,0.00971788,-0.11749416000000001,43.5,1.7415697108628585,18.462556072243586,4.6819996438479995e-12,0.14435340565418933,118.01153913476087,4.238666811482723,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-735-BTC-BG,SEG Solar Inc,Mono-c-Si,1,735.0,704.0,3.03,,,22.0,18.76,49.75,17.73,41.46,0.014820400000000001,-0.1157185,43.4,1.7110055979747847,18.778686776256933,4.3527619346643344e-12,0.16160066535483544,162.23389437647648,3.1356924412942644,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-740-BHC-BG,SEG Solar Inc,Mono-c-Si,1,740.0,706.1,3.03,,,22.0,18.53,50.57,17.42,42.5,0.009765310000000001,-0.11772696000000002,43.5,1.7453469635981445,18.552923951239933,4.728903217278807e-12,0.14353332062845048,116.02155341541945,4.283997385656141,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-740-BTC-BG,SEG Solar Inc,Mono-c-Si,1,740.0,708.9,3.03,,,22.0,18.82,49.94,17.79,41.6,0.0148678,-0.11616044,43.4,1.7170410808783738,18.838581333092275,4.331048753599171e-12,0.1628774063895542,164.96947644032505,3.064281426297179,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-745-BHC-BG,SEG Solar Inc,Mono-c-Si,1,745.0,711.0,3.03,,,22.0,18.62,50.67,17.5,42.59,0.00981274,-0.11795976000000001,43.5,1.749123411797174,18.64328957905304,4.776001256989169e-12,0.14272096804645382,114.10530095716767,4.328953316604449,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-745-BTC-BG,SEG Solar Inc,Mono-c-Si,1,745.0,713.8,3.03,,,22.0,18.88,50.12,17.85,41.74,0.0149152,-0.11657912,43.4,1.7228952979886722,18.89842962900979,4.3214075934407325e-12,0.16358231731668232,167.5798331586349,3.0168767911277063,-0.2573,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-750-BHC-BG,SEG Solar Inc,Mono-c-Si,1,750.0,715.8,3.03,,,22.0,18.71,50.77,17.58,42.68,0.00986017,-0.11819256000000002,43.5,1.7528989202959109,18.7336529683925,4.823283544381244e-12,0.14191621608404792,112.25873898106758,4.3736459970286505,-0.2794,N,2025.7.3,6/23/2025,4.0,bootstrapping +SEG Solar Inc SEG-755-BHC-BG,SEG Solar Inc,Mono-c-Si,1,755.0,720.7,3.03,,,22.0,18.8,50.87,17.66,42.77,0.009907599999999999,-0.11842536,43.5,1.756673491721458,18.824014131499005,4.870748773742222e-12,0.1411189596627305,110.47813424639418,4.418084568147822,-0.2794,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN245P-10,S-Energy Co Ltd,Multi-c-Si,0,245.0,221.7,1.6335,1.65,0.99,60.0,8.85,37.3,8.39,29.2,0.004425,-0.11563,46.5,1.4657261062827072,8.850003973457834,7.851557096318279e-11,0.44884860892975664,999995.707527144,4.279128644250121,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN245P-15,S-Energy Co Ltd,Multi-c-Si,0,245.0,222.0,1.663335,1.665,0.999,60.0,8.85,37.3,8.39,29.2,0.004548603351955307,-0.11747013333333334,45.32,1.4964307545719326,8.850003878172174,1.3235091514637985e-10,0.43802693835890494,999999.9193415329,7.027863050512692,-0.43780959752321985,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN250P-10,S-Energy Co Ltd,Multi-c-Si,0,250.0,226.4,1.6335,1.65,0.99,60.0,8.86,37.3,8.42,29.7,0.00443,-0.11563,46.5,1.478591503489063,8.860003326426515,9.808686023750516e-11,0.3753438295863863,999993.8371099966,6.156284213898308,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN250P-15,S-Energy Co Ltd,Multi-c-Si,0,250.0,226.6,1.663335,1.665,0.999,60.0,8.86,37.3,8.42,29.7,0.004553743016759777,-0.11747013333333334,45.32,1.5097305594682955,8.86000322839768,1.650368420544039e-10,0.36423957300158216,999999.9278646876,8.938426068002801,-0.43780959752321985,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN255P-10,S-Energy Co Ltd,Multi-c-Si,0,255.0,231.0,1.6335,1.65,0.99,60.0,8.93,37.6,8.5,30.0,0.004465,-0.11656,46.5,1.4929318017365858,8.930003227425395,1.0303722475955086e-10,0.3613250596152826,999999.7396081251,6.510659889407953,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN255P-15,S-Energy Co Ltd,Multi-c-Si,0,255.0,231.3,1.663335,1.665,0.999,60.0,8.93,37.6,8.5,30.0,0.0045897206703910615,-0.11841493333333333,45.32,1.5244033160505932,8.930003127511034,1.7330363372938675e-10,0.3500936093518922,999999.7360531249,9.299016644330402,-0.43780959752321985,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN260P-10,S-Energy Co Ltd,Multi-c-Si,0,260.0,235.7,1.6335,1.65,0.99,60.0,8.98,38.0,8.6,30.2,0.00449,-0.1178,46.5,1.5107355093021237,8.98028853161205,1.0694919245858427e-10,0.3501980351528151,10899.278771013262,6.78399307336627,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN260P-15,S-Energy Co Ltd,Multi-c-Si,0,260.0,235.9,1.663335,1.665,0.999,60.0,8.98,38.0,8.6,30.2,0.004615418994413408,-0.11967466666666667,45.32,1.5425354446248185,8.980237166135314,1.7963934222700037e-10,0.33866532038140634,12823.198931000228,9.567416345896678,-0.43780959752321985,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN265P-10,S-Energy Co Ltd,Multi-c-Si,0,265.0,240.3,1.6335,1.65,0.99,60.0,9.0,38.3,8.71,30.5,0.0045,-0.11873,46.5,1.5313946168233317,9.000234970047247,1.2371811256053288e-10,0.28995686761032624,11106.172741564971,8.024984730583776,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN265P-15,S-Energy Co Ltd,Multi-c-Si,0,265.0,240.6,1.663335,1.665,0.999,60.0,9.04,38.1,8.64,30.7,0.004646256983240223,-0.1199896,45.32,1.5546142520932131,9.04000267180336,2.0540611066981946e-10,0.29544882806684936,999997.5630855955,10.697071158502053,-0.43780959752321985,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN270P-10,S-Energy Co Ltd,Multi-c-Si,0,270.0,248.4,1.58,,,60.0,9.1,38.3,8.72,30.9,0.00546,-0.1149,45.31,1.4928158239508795,9.100211578797653,6.554810226473454e-11,0.3039213019638054,13071.670895831256,5.859302215772543,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN275M-10(B),S-Energy Co Ltd,Mono-c-Si,0,275.0,247.1,1.58,,,60.0,9.23,38.2,8.9,30.8,0.0032305000000000007,-0.10810600000000001,50.9,1.4520677257243757,9.230002658615764,3.468000934578837e-11,0.287961370021924,999792.8346138465,6.834668652039216,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN280M-10,S-Energy Co Ltd,Mono-c-Si,0,280.0,255.5,1.5811,,,60.0,9.29,38.3,8.79,31.9,0.003716,-0.108772,47.74,1.4740342353902975,9.294478566916235,4.7845787275965e-11,0.21358899550350982,443.05284828710865,9.164646270427863,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN280M-10(B),S-Energy Co Ltd,Mono-c-Si,0,280.0,251.7,1.58,,,60.0,9.29,38.3,8.95,31.2,0.0032515,-0.10838899999999999,50.9,1.4622565016400706,9.290208443810158,3.9142909437780963e-11,0.2515916997483746,11213.039019887578,7.82646832375414,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN285M-10,S-Energy Co Ltd,Mono-c-Si,0,285.0,260.2,1.5811,,,60.0,9.37,38.4,8.87,32.1,0.0037479999999999996,-0.10905599999999999,47.74,1.480346899763707,9.374078286794543,5.0401442874662376e-11,0.19717355007966625,453.0128246807854,9.546771855461435,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN285M-10(B),S-Energy Co Ltd,Mono-c-Si,0,285.0,256.4,1.58,,,60.0,9.37,38.4,9.0,31.6,0.0032795,-0.10867199999999999,50.9,1.4706128476786546,9.37016004993892,4.280603824879534e-11,0.22647507375914697,13258.813147819828,8.530794009727728,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN290M-10,S-Energy Co Ltd,Mono-c-Si,0,290.0,264.9,1.5811,,,60.0,9.63,39.6,9.05,32.0,0.0038520000000000004,-0.112464,47.74,1.505041635140035,9.641751775453102,3.5538837362259615e-11,0.3381410770486642,277.0899308786833,6.287271976434536,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN290M-10(B),S-Energy Co Ltd,Mono-c-Si,0,290.0,261.0,1.58,,,60.0,9.63,39.6,9.05,32.0,0.0033705000000000007,-0.112068,50.9,1.505909235200148,9.641719047288486,3.6082730315646395e-11,0.3379363712569498,277.69555427465895,6.860233775588628,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN295M-10,S-Energy Co Ltd,Mono-c-Si,0,295.0,269.6,1.5811,,,60.0,9.66,39.7,9.1,32.4,0.0038640000000000002,-0.112748,47.74,1.514962202749527,9.668948089608653,3.971722908573015e-11,0.2971655327470136,320.80804317882183,7.211509867179869,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN295M-10(B),S-Energy Co Ltd,Mono-c-Si,0,295.0,265.7,1.58,,,60.0,9.66,39.7,9.1,32.4,0.0033810000000000003,-0.11235099999999999,50.9,1.515821988934495,9.668920284236057,4.031313891638642e-11,0.2969623421163982,321.58799226207526,7.785787970350266,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN295P-10,S-Energy Co Ltd,Multi-c-Si,0,295.0,266.5,1.9503,1.97,0.99,72.0,8.85,44.8,8.39,35.2,0.004425,-0.13887999999999998,46.9,1.7633373808561483,8.85000462729017,8.186447465011222e-11,0.5227389915019333,999999.8416202941,4.630701768921494,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN295P-15,S-Energy Co Ltd,Multi-c-Si,0,295.0,267.5,1.9830150000000002,1.985,0.999,72.0,8.85,44.8,8.4,35.1,0.0038396825396825396,-0.1330185022026432,46.69,1.72424473926185,8.85000480872289,4.601850661456289e-11,0.543271216637068,999989.6583103207,4.396725662732223,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN300M-10,S-Energy Co Ltd,Mono-c-Si,0,300.0,274.3,1.5811,,,60.0,9.68,39.9,9.14,32.8,0.003872,-0.113316,47.74,1.5266660437179838,9.686688743700797,4.2764911871108906e-11,0.268075106190549,387.96031335764656,7.827499726285133,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN300M-10(B),S-Energy Co Ltd,Mono-c-Si,0,300.0,270.3,1.58,,,60.0,9.68,39.9,9.14,32.8,0.0033880000000000004,-0.11291699999999999,50.9,1.5275242073068045,9.686664654381337,4.3398672366173305e-11,0.2678721789272339,389.0678502857147,8.402719078689426,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN300P-10,S-Energy Co Ltd,Multi-c-Si,0,300.0,271.2,1.9503,1.97,0.99,72.0,8.88,44.9,8.44,35.5,0.00444,-0.13919,46.9,1.774293377700172,8.880004281526807,9.082815063824503e-11,0.48204986006935757,999999.832792052,5.481586845452906,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN300P-15,S-Energy Co Ltd,Multi-c-Si,0,300.0,272.2,1.9830150000000002,1.985,0.999,72.0,8.88,44.9,8.44,35.6,0.003852698412698413,-0.13331541850220266,46.69,1.7382117464265727,8.88000429010391,5.371395866437327e-11,0.4830474647464848,999990.5779396194,5.676738629794141,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN305M-10(B),S-Energy Co Ltd,Mono-c-Si,0,305.0,275.0,1.58,,,60.0,9.71,40.1,9.18,33.2,0.0033985000000000005,-0.113483,50.9,1.5399528137898053,9.715447418082258,4.723964107052773e-11,0.23875000216210548,425.57089550896524,9.11542769994558,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN305M-10T,S-Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN305P-10,S-Energy Co Ltd,Multi-c-Si,0,305.0,275.8,1.9503,1.97,0.99,72.0,8.9,45.1,8.47,36.0,0.004450000000000001,-0.13981,46.9,1.7909462683313435,8.900003860522157,1.0301240306675879e-10,0.43367812383538146,999999.8167011862,6.537473609807724,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN305P-15,S-Energy Co Ltd,Multi-c-Si,0,305.0,276.8,1.9830150000000002,1.985,0.999,72.0,8.9,45.1,8.47,36.0,0.003861375661375662,-0.1339092511013216,46.69,1.7521599430143966,8.90000398374316,5.899239026639607e-11,0.4475537369666791,999999.8192427132,6.458342253808214,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN310M-10(B),S-Energy Co Ltd,Mono-c-Si,0,310.0,279.7,1.58,,,60.0,9.74,40.4,9.22,33.6,0.003409,-0.11433199999999998,50.9,1.5541762486279562,9.744447647789238,4.963188488236296e-11,0.22089534885636977,483.74351379780927,9.519133580197503,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN310M-10T,S-Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN310P-10,S-Energy Co Ltd,Multi-c-Si,0,310.0,280.5,1.9503,1.97,0.99,72.0,8.96,45.4,8.54,36.3,0.0044800000000000005,-0.14074,46.9,1.805461062391285,8.960003751208754,1.0753918640498956e-10,0.4185776746924301,999999.5300410322,6.84937245666504,-0.42,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN310P-15,S-Energy Co Ltd,Multi-c-Si,0,310.0,281.5,1.9830150000000002,1.985,0.999,72.0,8.96,45.4,8.54,36.3,0.0038874074074074084,-0.13480000000000003,46.69,1.7663027461990388,8.960003876680954,6.158256447408004e-11,0.4326102550535958,999999.5361610248,6.769601814469227,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN315M-10T,S-Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN315P-10,S-Energy Co Ltd,Multi-c-Si,0,315.0,285.1,1.9503,1.97,0.99,72.0,9.01,45.8,8.52,36.6,0.004505,-0.14198,46.9,1.8177424866799614,9.012023729543468,1.02612391303531e-10,0.45105972380042997,2008.1981041706988,6.406167500583849,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN315P-15,S-Energy Co Ltd,Multi-c-Si,0,315.0,286.2,1.9830150000000002,1.985,0.999,72.0,9.01,45.6,8.61,36.6,0.0039091005291005294,-0.13539383259911897,46.69,1.7791606888641536,9.010003619567431,6.663892279882813e-11,0.40167554244365333,999992.3014724853,7.402062880856135,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SC20-60MAE-320V,S-Energy Co Ltd,Mono-c-Si,0,320.0,295.8,1.68,,,60.0,10.17,40.2,9.61,33.3,0.0042714,-0.10854000000000001,47.1,1.4837512675330178,10.177705301050729,1.720495370586469e-11,0.2402669611812263,317.1212729862857,4.967177987521083,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MBE-320V,S-Energy Co Ltd,Mono-c-Si,0,320.0,295.8,1.68,,,60.0,10.17,40.2,9.61,33.3,0.0042714,-0.10854000000000001,47.1,1.4837512675330178,10.177705301050729,1.720495370586469e-11,0.2402669611812263,317.1212729862857,4.967177987521083,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MCE-320V,S-Energy Co Ltd,Mono-c-Si,0,320.0,295.8,1.68,,,60.0,10.17,40.2,9.61,33.3,0.0042714,-0.10854000000000001,47.1,1.4837512675330178,10.177705301050729,1.720495370586469e-11,0.2402669611812263,317.1212729862857,4.967177987521083,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-60MAE-320V,S-Energy Co Ltd,Mono-c-Si,0,320.0,294.5,1.66,,,60.0,10.12,40.6,9.59,33.4,0.0041492000000000005,-0.11002600000000001,47.0,1.5273420412879428,10.124669735518472,2.8697896630492972e-11,0.26356224006959605,571.1778898826905,9.033504698163869,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-60MBE-320V,S-Energy Co Ltd,Mono-c-Si,0,320.0,294.5,1.66,,,60.0,10.12,40.6,9.59,33.4,0.0041492000000000005,-0.11002600000000001,47.0,1.5273420412879428,10.124669735518472,2.8697896630492972e-11,0.26356224006959605,571.1778898826905,9.033504698163869,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-60MCE-320V,S-Energy Co Ltd,Mono-c-Si,0,320.0,294.5,1.66,,,60.0,10.12,40.6,9.59,33.4,0.0041492000000000005,-0.11002600000000001,47.0,1.5273420412879428,10.124669735518472,2.8697896630492972e-11,0.26356224006959605,571.1778898826905,9.033504698163869,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN320P-10,S-Energy Co Ltd,Multi-c-Si,0,320.0,291.0,1.9503,1.97,0.99,72.0,9.07,45.9,8.68,36.9,0.0039351322751322755,-0.13628458149779737,46.69,1.7933116643366955,9.070003508437384,6.946922847794771e-11,0.38675568483625405,999959.6603157294,7.704790110713404,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN320P-15,S-Energy Co Ltd,Multi-c-Si,0,320.0,290.8,1.9830150000000002,1.985,0.999,72.0,9.07,45.9,8.68,36.9,0.0039351322751322755,-0.13628458149779737,46.69,1.7933116643366955,9.070003508437384,6.946922847794771e-11,0.38675568483625405,999959.6603157294,7.704790110713404,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SC20-60MAE-325V,S-Energy Co Ltd,Mono-c-Si,0,325.0,300.6,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0043176,-0.10908,47.1,1.4921999840145321,10.288019227332299,1.7720977861876273e-11,0.23478710718622423,300.97805785146613,5.129321647434609,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MBE-325V,S-Energy Co Ltd,Mono-c-Si,0,325.0,300.6,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0043176,-0.10908,47.1,1.4921999840145321,10.288019227332299,1.7720977861876273e-11,0.23478710718622423,300.97805785146613,5.129321647434609,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MCE-325V,S-Energy Co Ltd,Mono-c-Si,0,325.0,300.6,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0043176,-0.10908,47.1,1.4921999840145321,10.288019227332299,1.7720977861876273e-11,0.23478710718622423,300.97805785146613,5.129321647434609,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-60MAE-325V,S-Energy Co Ltd,Mono-c-Si,0,325.0,299.3,1.66,,,60.0,10.24,40.7,9.68,33.6,0.004198400000000001,-0.11029700000000002,47.0,1.535673305617583,10.246629291634255,3.132668334230059e-11,0.24696445393023286,381.4760607587113,9.71584182481038,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-60MBE-325V,S-Energy Co Ltd,Mono-c-Si,0,325.0,299.3,1.66,,,60.0,10.24,40.7,9.68,33.6,0.004198400000000001,-0.11029700000000002,47.0,1.535673305617583,10.246629291634255,3.132668334230059e-11,0.24696445393023286,381.4760607587113,9.71584182481038,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-60MCE-325V,S-Energy Co Ltd,Mono-c-Si,0,325.0,299.3,1.66,,,60.0,10.24,40.7,9.68,33.6,0.004198400000000001,-0.11029700000000002,47.0,1.535673305617583,10.246629291634255,3.132668334230059e-11,0.24696445393023286,381.4760607587113,9.71584182481038,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN325P-10,S-Energy Co Ltd,Multi-c-Si,0,325.0,295.6,1.9503,1.97,0.99,72.0,9.1,46.0,8.72,37.3,0.0039481481481481485,-0.13658149779735684,46.69,1.8051845980080439,9.1000030970024,7.803304102578582e-11,0.3402317861686471,999826.4195336393,8.68858974662939,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN325P-15,S-Energy Co Ltd,Multi-c-Si,0,325.0,295.5,1.9830150000000002,1.985,0.999,72.0,9.1,46.0,8.72,37.3,0.0039481481481481485,-0.13658149779735684,46.69,1.8051845980080439,9.1000030970024,7.803304102578582e-11,0.3402317861686471,999826.4195336393,8.68858974662939,-0.407356177302735,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SC20-60MAE-330V,S-Energy Co Ltd,Mono-c-Si,0,330.0,305.3,1.68,,,60.0,10.35,40.6,9.8,33.7,0.004347,-0.10962000000000001,47.1,1.498603176577434,10.356165667258166,1.7575828957540443e-11,0.23050415722083956,386.93590717042076,4.991369720804051,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MBE-330V,S-Energy Co Ltd,Mono-c-Si,0,330.0,305.3,1.68,,,60.0,10.35,40.6,9.8,33.7,0.004347,-0.10962000000000001,47.1,1.498603176577434,10.356165667258166,1.7575828957540443e-11,0.23050415722083956,386.93590717042076,4.991369720804051,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MCE-330V,S-Energy Co Ltd,Mono-c-Si,0,330.0,305.3,1.68,,,60.0,10.35,40.6,9.8,33.7,0.004347,-0.10962000000000001,47.1,1.498603176577434,10.356165667258166,1.7575828957540443e-11,0.23050415722083956,386.93590717042076,4.991369720804051,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN330M-10(B),S-Energy Co Ltd,Mono-c-Si,0,330.0,292.8,1.89,,,72.0,9.28,45.1,8.91,37.1,0.0033407999999999997,-0.127182,54.1,1.7202546897467266,9.280213250821241,3.814711681810808e-11,0.2742232426826276,11933.333643117081,7.98317130763147,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SC20-60MAE-335V,S-Energy Co Ltd,Mono-c-Si,0,335.0,310.1,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0043764,-0.11016,47.1,1.5050215536142952,10.42437535820173,1.743766805539633e-11,0.22629368651919776,538.9227898271334,4.856900020829881,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MBE-335V,S-Energy Co Ltd,Mono-c-Si,0,335.0,310.1,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0043764,-0.11016,47.1,1.5050215536142952,10.42437535820173,1.743766805539633e-11,0.22629368651919776,538.9227898271334,4.856900020829881,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MCE-335V,S-Energy Co Ltd,Mono-c-Si,0,335.0,310.1,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0043764,-0.11016,47.1,1.5050215536142952,10.42437535820173,1.743766805539633e-11,0.22629368651919776,538.9227898271334,4.856900020829881,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN335M-10(B),S-Energy Co Ltd,Mono-c-Si,0,335.0,297.4,1.89,,,72.0,9.32,45.2,8.95,37.4,0.0033552,-0.127464,54.1,1.7281034972946459,9.320002316372884,4.074521137882512e-11,0.24852009196763705,999978.1071669498,8.518700425418448,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SC20-60MAE-340V,S-Energy Co Ltd,Mono-c-Si,0,340.0,314.8,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0044184,-0.11070000000000002,47.1,1.513511928621397,10.524759018039337,1.79473568641041e-11,0.22131352799625853,489.2224251686849,5.023213738663144,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MBE-340V,S-Energy Co Ltd,Mono-c-Si,0,340.0,314.8,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0044184,-0.11070000000000002,47.1,1.513511928621397,10.524759018039337,1.79473568641041e-11,0.22131352799625853,489.2224251686849,5.023213738663144,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-60MCE-340V,S-Energy Co Ltd,Mono-c-Si,0,340.0,314.8,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0044184,-0.11070000000000002,47.1,1.513511928621397,10.524759018039337,1.79473568641041e-11,0.22131352799625853,489.2224251686849,5.023213738663144,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN340M-10,S-Energy Co Ltd,Mono-c-Si,0,340.0,313.1,1.8915,,,72.0,9.38,45.2,8.93,38.1,0.0036582000000000003,-0.127012,46.06,1.7290036388389094,9.381278719273906,4.143622824477694e-11,0.19593627532368563,1437.283638657493,8.972521503186927,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN340M-10(B),S-Energy Co Ltd,Mono-c-Si,0,340.0,302.0,1.89,,,72.0,9.38,45.2,8.98,37.7,0.0033768,-0.127464,54.1,1.7318447688548282,9.380002126899768,4.3391320542738633e-11,0.22673709904548356,999999.5790929542,9.013589216726192,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SN345M-10,S-Energy Co Ltd,Mono-c-Si,0,345.0,317.8,1.8915,,,72.0,9.41,45.3,8.96,38.5,0.0036699000000000002,-0.127293,46.06,1.740075113728351,9.411188789578832,4.6322910984141825e-11,0.15524041951995235,1228.823375103097,9.929699177030509,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN345M-10(B),S-Energy Co Ltd,Mono-c-Si,0,345.0,306.6,1.89,,,72.0,9.41,45.3,9.11,38.0,0.0033875999999999997,-0.12774599999999997,54.1,1.7491853626997744,9.410107263833343,5.3230800473322223e-11,0.13776284387741064,12085.6116862614,10.794799470731725,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +S-Energy Co Ltd SL40-60MAI-350V,S-Energy Co Ltd,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MBI-350V,S-Energy Co Ltd,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MCI-350V,S-Energy Co Ltd,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN350M-10,S-Energy Co Ltd,Mono-c-Si,0,350.0,322.5,1.8915,,,72.0,9.68,46.7,9.14,38.3,0.0037752,-0.131227,46.06,1.7683240925314965,9.687187951517611,3.2514948477020344e-11,0.3290282377246696,443.1016828955975,6.617299904857258,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN350M-10(B),S-Energy Co Ltd,Mono-c-Si,0,350.0,311.2,1.89,,,72.0,9.68,46.7,9.14,38.3,0.0034847999999999997,-0.131694,54.1,1.779191745302493,9.686915582327671,3.821841216452257e-11,0.32645666912149546,456.9536543656994,7.668072837808424,-0.384,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MAI-355V,S-Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MBI-355V,S-Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MCI-355V,S-Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN355M-10,S-Energy Co Ltd,Mono-c-Si,0,355.0,327.3,1.8915,,,72.0,9.71,46.8,9.18,38.7,0.0037869,-0.131508,46.06,1.7786297351272717,9.715876564107115,3.5954121305480376e-11,0.28872024088799314,477.05998845440934,7.456425856405956,-0.376,N,2025.7.3,6/23/2025,4.0,bootstrapping +S-Energy Co Ltd SN355M-10(B),S-Energy Co Ltd,Mono-c-Si,0,355.0,315.8,1.89,,,72.0,9.71,46.8,9.18,38.7,0.0034955999999999997,-0.13197599999999998,54.1,1.7895852304317925,9.715637137618247,4.225086987749789e-11,0.28612393714099327,492.8500411579625,8.512310893761468,-0.384,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-360V,S-Energy Co Ltd,Mono-c-Si,1,360.0,335.8,1.99,,,72.0,9.68,47.7,9.18,39.2,0.0031556799999999997,-0.1269297,43.8,1.75337668571824,9.684748836244431,1.472806128667323e-11,0.3382822754920748,689.5526216940445,5.709477017996668,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MAI-360V,S-Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MBI-360V,S-Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MCI-360V,S-Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MAI-360V,S-Energy Co Ltd,Mono-c-Si,0,360.0,333.6,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MCI-360V,S-Energy Co Ltd,Mono-c-Si,0,360.0,333.6,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN360M-10,S-Energy Co Ltd,Mono-c-Si,0,360.0,332.0,1.8915,,,72.0,9.72,47.0,9.21,39.1,0.0037908000000000004,-0.13207000000000002,46.06,1.7898574085971934,9.724143107213308,3.8039159169038886e-11,0.26044460209193687,611.0200245730462,7.92961816878031,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN360M-10(B),S-Energy Co Ltd,Mono-c-Si,0,360.0,320.5,1.89,,,72.0,9.72,47.0,9.21,39.1,0.0034992,-0.13254,54.1,1.8008949492812971,9.723935782688407,4.46947684877534e-11,0.25782709702120343,636.742296224345,8.988285810884973,-0.384,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN360M-10T,S-Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-365V,S-Energy Co Ltd,Mono-c-Si,1,365.0,340.6,1.99,,,72.0,9.72,47.9,9.25,39.5,0.00316872,-0.1274619,43.8,1.7608969221362214,9.72200059615587,1.488281251405169e-11,0.32152217580050313,1562.1321938137003,5.749352111334836,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MAI-365V,S-Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MBI-365V,S-Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MCI-365V,S-Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60BHI-365V,S-Energy Co Ltd,Mono-c-Si,1,365.0,340.7,1.83,,,60.0,11.19,41.1,10.66,34.3,0.00349128,-0.11031240000000002,45.32,1.4825121309335765,11.192655571528878,1.0163192291480109e-11,0.20342421016254392,857.185324360902,0.5145881496169558,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MAI-365V,S-Energy Co Ltd,Mono-c-Si,0,365.0,338.3,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MCI-365V,S-Energy Co Ltd,Mono-c-Si,0,365.0,338.3,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN365M-10(B),S-Energy Co Ltd,Mono-c-Si,0,365.0,325.1,1.89,,,72.0,9.74,47.2,9.25,39.4,0.0035064,-0.133104,54.1,1.8097143547878207,9.742487056746011,4.56465746224925e-11,0.24200756450588165,947.7683974045095,9.146449353767183,-0.384,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN365M-10T,S-Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-370V,S-Energy Co Ltd,Mono-c-Si,1,370.0,345.3,1.99,,,72.0,9.79,48.2,9.32,39.7,0.0031915399999999992,-0.12826020000000002,43.8,1.7673290987083512,9.790007185335138,1.4007314567221396e-11,0.3277728308729297,446594.0889380231,5.159063741778002,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MAI-370V,S-Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MBI-370V,S-Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-60MCI-370V,S-Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60BHI-370V,S-Energy Co Ltd,Mono-c-Si,1,370.0,345.5,1.83,,,60.0,11.26,41.4,10.72,34.5,0.0035131200000000002,-0.11111760000000001,45.32,1.4926967531021205,11.263145563061638,1.0100590684614451e-11,0.2089687860073676,748.0337697733061,0.4154669057332421,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MAI-370V,S-Energy Co Ltd,Mono-c-Si,0,370.0,343.1,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MCI-370V,S-Energy Co Ltd,Mono-c-Si,0,370.0,343.1,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN370M-10(B),S-Energy Co Ltd,Mono-c-Si,0,370.0,329.7,1.89,,,72.0,9.76,47.5,9.29,39.7,0.0035136,-0.13394999999999999,54.1,1.8203588485746223,9.761164198594695,4.5296358394252774e-11,0.23721628428286262,1988.6909126665182,9.051089545166569,-0.384,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN370M-10T,S-Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-375V,S-Energy Co Ltd,Mono-c-Si,1,375.0,350.1,1.99,,,72.0,9.85,48.5,9.4,39.9,0.0032110999999999997,-0.1290585,43.8,1.779304242638775,9.850004448586068,1.430545482799251e-11,0.33278271921562674,736855.5929858502,5.286446666037689,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60BHI-375V,S-Energy Co Ltd,Mono-c-Si,1,375.0,350.3,1.83,,,60.0,11.32,41.6,10.78,34.8,0.00353184,-0.11165440000000001,45.32,1.50255649164443,11.322966875362306,1.0662684285075631e-11,0.19473513588085828,743.0045064023695,0.8149591490204783,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MAI-375V,S-Energy Co Ltd,Mono-c-Si,0,375.0,347.9,1.83,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MCI-375V,S-Energy Co Ltd,Mono-c-Si,0,375.0,347.9,1.83,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN375M-10T,S-Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MAE-380V,S-Energy Co Ltd,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035210000000000007,-0.12457900000000001,44.3,1.8525361954361788,10.06406052670755,5.289513913858062e-11,0.2661199539671132,659.3151683966917,20.01887110848221,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MCE-380V,S-Energy Co Ltd,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035210000000000007,-0.12457900000000001,44.3,1.8525361954361788,10.06406052670755,5.289513913858062e-11,0.2661199539671132,659.3151683966917,20.01887110848221,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-380V,S-Energy Co Ltd,Mono-c-Si,1,380.0,354.9,1.99,,,72.0,9.94,48.8,9.46,40.2,0.00324044,-0.1298568,43.8,1.7892102038277642,9.94000714996007,1.4196194125987256e-11,0.3262342364345687,453539.2695784441,5.143638452280042,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60BHI-380V,S-Energy Co Ltd,Mono-c-Si,1,380.0,355.1,1.83,,,60.0,11.4,41.8,10.86,35.0,0.0035568,-0.1121912,45.32,1.5102257662692662,11.402730747941662,1.0829590096307663e-11,0.19088309866610503,796.8759471926134,0.8832772989449614,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MAI-380V,S-Energy Co Ltd,Mono-c-Si,0,380.0,352.7,1.83,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60MCI-380V,S-Energy Co Ltd,Mono-c-Si,0,380.0,352.7,1.83,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MAE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.0037443999999999997,-0.124872,44.4,1.8698526786043947,10.123743942074604,5.766551620178159e-11,0.25896992506592903,700.0043568007427,21.242773905135284,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MBE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.0037443999999999997,-0.124872,44.4,1.8698526786043947,10.123743942074604,5.766551620178159e-11,0.25896992506592903,700.0043568007427,21.242773905135284,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MCE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.0037443999999999997,-0.124872,44.4,1.8698526786043947,10.123743942074604,5.766551620178159e-11,0.25896992506592903,700.0043568007427,21.242773905135284,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MAE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.0035420000000000004,-0.125356,44.3,1.8650107162534195,10.123835093917702,5.3910719835367076e-11,0.260066817737451,686.2612407053117,20.1441385078866,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MCE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.0035420000000000004,-0.125356,44.3,1.8650107162534195,10.123835093917702,5.3910719835367076e-11,0.260066817737451,686.2612407053117,20.1441385078866,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-385V,S-Energy Co Ltd,Mono-c-Si,1,385.0,359.7,1.99,,,72.0,10.03,49.0,9.53,40.4,0.00326978,-0.130389,43.8,1.80250495986218,10.033347138476286,1.560249218969472e-11,0.3195321732586691,957.5066370870326,5.891980686967847,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-60BHI-385V,S-Energy Co Ltd,Mono-c-Si,1,385.0,359.9,1.83,,,60.0,11.47,42.0,10.94,35.2,0.00357864,-0.11272800000000001,45.32,1.5172741536443375,11.471873718624392,1.0875377592628634e-11,0.18732269081304131,1146.6990156981208,0.8625772931840445,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MAE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.97,,,72.0,10.09,48.7,9.58,40.2,0.0040360000000000005,-0.13051600000000002,47.8,1.8104376310136365,10.093603382245158,2.085727943539022e-11,0.30601554962005956,856.8884583948262,7.487236951628097,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MBE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.97,,,72.0,10.09,48.7,9.58,40.2,0.0040360000000000005,-0.13051600000000002,47.8,1.8104376310136365,10.093603382245158,2.085727943539022e-11,0.30601554962005956,856.8884583948262,7.487236951628097,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MCE-385V,S-Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.97,,,72.0,10.09,48.7,9.58,40.2,0.0040360000000000005,-0.13051600000000002,47.8,1.8104376310136365,10.093603382245158,2.085727943539022e-11,0.30601554962005956,856.8884583948262,7.487236951628097,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MAE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,360.9,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037814000000000003,-0.12513,44.4,1.8745723049958543,10.224107001756801,5.889133510344368e-11,0.2548830886090516,634.2595967539417,21.35478312823131,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MBE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,360.9,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037814000000000003,-0.12513,44.4,1.8745723049958543,10.224107001756801,5.889133510344368e-11,0.2548830886090516,634.2595967539417,21.35478312823131,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MCE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,360.9,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037814000000000003,-0.12513,44.4,1.8745723049958543,10.224107001756801,5.889133510344368e-11,0.2548830886090516,634.2595967539417,21.35478312823131,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MAE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0035770000000000008,-0.125615,44.3,1.869718396773279,10.224199833779481,5.5058637375160914e-11,0.25597292047355635,622.8920555108303,20.255460870871136,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MCE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0035770000000000008,-0.125615,44.3,1.869718396773279,10.224199833779481,5.5058637375160914e-11,0.25597292047355635,622.8920555108303,20.255460870871136,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SD25-72BDE-390V,S-Energy Co Ltd,Mono-c-Si,1,390.0,364.5,1.99,,,72.0,10.11,49.3,9.61,40.6,0.0032958599999999994,-0.1311873,43.8,1.8121311060635106,10.113005149072462,1.5407163303438524e-11,0.3246264701179815,1092.1163467986844,5.713718096467374,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MAE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.97,,,72.0,10.18,48.9,9.66,40.4,0.004072,-0.131052,47.8,1.81915546740789,10.18408757780549,2.143023460265269e-11,0.30036278286652757,748.0452599322397,7.648639130524166,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MBE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.97,,,72.0,10.18,48.9,9.66,40.4,0.004072,-0.131052,47.8,1.81915546740789,10.18408757780549,2.143023460265269e-11,0.30036278286652757,748.0452599322397,7.648639130524166,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MCE-390V,S-Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.97,,,72.0,10.18,48.9,9.66,40.4,0.004072,-0.131052,47.8,1.81915546740789,10.18408757780549,2.143023460265269e-11,0.30036278286652757,748.0452599322397,7.648639130524166,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MAE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0038147000000000003,-0.125646,44.4,1.8836079619577168,10.31448255058471,6.044148551653871e-11,0.2496287427556831,574.1535675190752,21.526102879209898,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MBE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0038147000000000003,-0.125646,44.4,1.8836079619577168,10.31448255058471,6.044148551653871e-11,0.2496287427556831,574.1535675190752,21.526102879209898,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC20-72MCE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0038147000000000003,-0.125646,44.4,1.8836079619577168,10.31448255058471,6.044148551653871e-11,0.2496287427556831,574.1535675190752,21.526102879209898,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MAE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036085000000000006,-0.12613300000000002,44.3,1.8787310658481013,10.31457654049213,5.651087420974826e-11,0.25071555783219607,564.8103627891328,20.4257182255579,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MCE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036085000000000006,-0.12613300000000002,44.3,1.8787310658481013,10.31457654049213,5.651087420974826e-11,0.25071555783219607,564.8103627891328,20.4257182255579,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54BHJ-395V,S-Energy Co Ltd,Mono-c-Si,1,395.0,368.1,1.94,,,54.0,13.59,37.03,12.75,31.0,0.0047565,-0.09731484,45.6,1.3426552822754692,13.606588307155752,1.3988951876433354e-11,0.14224969405261037,116.53831396052826,3.733824916727701,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MAE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.97,,,72.0,10.27,49.1,9.74,40.6,0.004108,-0.131588,47.8,1.8278712230224883,10.274556650197713,2.2012819578679354e-11,0.294803977420137,664.44356682036,7.808486674714313,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MBE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.97,,,72.0,10.27,49.1,9.74,40.6,0.004108,-0.131588,47.8,1.8278712230224883,10.274556650197713,2.2012819578679354e-11,0.294803977420137,664.44356682036,7.808486674714313,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SN20-72MCE-395V,S-Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.97,,,72.0,10.27,49.1,9.74,40.6,0.004108,-0.131588,47.8,1.8278712230224883,10.274556650197713,2.2012819578679354e-11,0.294803977420137,664.44356682036,7.808486674714313,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MAE-400V,S-Energy Co Ltd,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036365000000000004,-0.126651,44.3,1.8877925850114659,10.394970628678296,5.796704935295767e-11,0.2457738030561143,513.7357995535735,20.600754731526383,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MCE-400V,S-Energy Co Ltd,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036365000000000004,-0.126651,44.3,1.8877925850114659,10.394970628678296,5.796704935295767e-11,0.2457738030561143,513.7357995535735,20.600754731526383,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54BHJ-400V,S-Energy Co Ltd,Mono-c-Si,1,400.0,372.9,1.94,,,54.0,13.68,37.2,12.84,31.17,0.004788000000000001,-0.0977616,45.6,1.368245749722663,13.695241162455638,2.0853014681115602e-11,0.13618256914737645,122.23329806894401,7.085284919966181,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MAE-405V,S-Energy Co Ltd,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036680000000000007,-0.127169,44.3,1.8968015783799659,10.48531818338852,5.946536787980653e-11,0.24068026436662399,474.28399223380427,20.767771669093406,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SC25-72MCE-405V,S-Energy Co Ltd,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036680000000000007,-0.127169,44.3,1.8968015783799659,10.48531818338852,5.946536787980653e-11,0.24068026436662399,474.28399223380427,20.767771669093406,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54BHJ-405V,S-Energy Co Ltd,Mono-c-Si,1,405.0,377.7,1.94,,,54.0,13.78,37.36,12.92,31.36,0.004823000000000001,-0.09818207999999999,45.6,1.3760968723671756,13.795726508897816,2.1806362653605427e-11,0.13072148197726605,114.54176138333841,7.41587797371275,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54TEP-405V,S-Energy Co Ltd,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54BHJ-410V,S-Energy Co Ltd,Mono-c-Si,1,410.0,382.5,1.94,,,54.0,13.86,37.54,13.0,31.55,0.004851,-0.09865512,45.6,1.3833293700763116,13.875160143988763,2.2201334550345892e-11,0.1271918482280151,116.28379159819653,7.520472537520646,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54TEP-410V,S-Energy Co Ltd,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MAI-420V,S-Energy Co Ltd,Mono-c-Si,0,420.0,391.6,2.19,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MBI-420V,S-Energy Co Ltd,Mono-c-Si,0,420.0,391.6,2.19,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MCI-420V,S-Energy Co Ltd,Mono-c-Si,0,420.0,391.6,2.19,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MAI-425V,S-Energy Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MBI-425V,S-Energy Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MCI-425V,S-Energy Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54TEP-425V,S-Energy Co Ltd,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MAI-430V,S-Energy Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MBI-430V,S-Energy Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MCI-430V,S-Energy Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-430V,S-Energy Co Ltd,Mono-c-Si,1,430.0,400.7,2.2048720000000004,,,72.0,11.2,48.6,10.65,40.4,0.0058464,-0.12864420000000001,46.18,1.7736195709576112,11.203608812022006,1.4014831304133904e-11,0.25259689697451,783.9381137137947,4.3315520029135905,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-430V,S-Energy Co Ltd,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-430V,S-Energy Co Ltd,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54TEP-430V,S-Energy Co Ltd,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MAI-435V,S-Energy Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MBI-435V,S-Energy Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MCI-435V,S-Energy Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-435V,S-Energy Co Ltd,Mono-c-Si,1,435.0,405.4,2.2048720000000004,,,72.0,11.28,48.8,10.72,40.6,0.00588816,-0.1291736,46.18,1.7821323295289642,11.284085713182504,1.4370187416705828e-11,0.24818858603407964,685.2089620092718,4.486572628156489,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-435V,S-Energy Co Ltd,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-435V,S-Energy Co Ltd,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54TEP-435V,S-Energy Co Ltd,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MAI-440V,S-Energy Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MBI-440V,S-Energy Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MCI-440V,S-Energy Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-440V,S-Energy Co Ltd,Mono-c-Si,1,440.0,410.2,2.2048720000000004,,,72.0,11.36,49.0,10.79,40.8,0.00592992,-0.12970299999999998,46.18,1.7906468120454178,11.364546684070904,1.4731730898878516e-11,0.24383738356960658,609.2336013054614,4.640564388186096,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-440V,S-Energy Co Ltd,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-440V,S-Energy Co Ltd,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL65-54TEP-440V,S-Energy Co Ltd,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MAI-445V,S-Energy Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MBI-445V,S-Energy Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL40-72MCI-445V,S-Energy Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-445V,S-Energy Co Ltd,Mono-c-Si,1,445.0,415.0,2.2048720000000004,,,72.0,11.44,49.2,10.86,41.0,0.00597168,-0.1302324,46.18,1.7991560127923258,11.444992006744556,1.5097907470607593e-11,0.23954361297106808,548.9533773374214,4.792628652127338,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-445V,S-Energy Co Ltd,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-445V,S-Energy Co Ltd,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-450V,S-Energy Co Ltd,Mono-c-Si,1,450.0,419.8,2.2048720000000004,,,72.0,11.52,49.4,10.93,41.2,0.00601344,-0.13076179999999998,46.18,1.7969841838686,11.520009160393652,1.325783494709557e-11,0.2372942764143096,298419.95043445873,3.6040100690140706,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-450V,S-Energy Co Ltd,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-450V,S-Energy Co Ltd,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-455V,S-Energy Co Ltd,Mono-c-Si,1,455.0,424.6,2.2048720000000004,,,72.0,11.6,49.6,11.0,41.4,0.0060552,-0.1312912,46.18,1.8045042992712832,11.600007575524174,1.339982873294223e-11,0.23328450508339485,357218.4381162309,3.6355084633908232,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-455V,S-Energy Co Ltd,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-455V,S-Energy Co Ltd,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72BDI-460V,S-Energy Co Ltd,Mono-c-Si,1,460.0,429.4,2.2048720000000004,,,72.0,11.67,49.8,11.06,41.6,0.00609174,-0.13182059999999998,46.18,1.8119950337359891,11.670006808861357,1.3524640770911125e-11,0.22953156131228208,393406.6492862048,3.662985431955832,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-460V,S-Energy Co Ltd,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-460V,S-Energy Co Ltd,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-465V,S-Energy Co Ltd,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-465V,S-Energy Co Ltd,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MAI-470V,S-Energy Co Ltd,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +S-Energy Co Ltd SL45-72MCI-470V,S-Energy Co Ltd,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-180-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,180.0,162.4,1.2766400000000002,1.58,0.808,72.0,5.31,44.9,4.97,36.21,0.00395595,-0.173763,46.3,1.8848333160167472,5.315608967258331,2.3647700775687246e-10,0.6380481091013653,604.0392147871029,-5.253131229130948,-0.4307,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-185-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,185.0,167.0,1.2766400000000002,1.58,0.808,72.0,5.44,45.0,5.09,36.31,0.0040528000000000005,-0.17415,46.3,1.8899838807857456,5.4458990460175,2.4508153414438294e-10,0.6196409411063,571.4224643806391,-5.1633214882157175,-0.4307,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-190-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,190.0,171.6,1.2766400000000002,1.58,0.808,72.0,5.57,45.1,5.22,36.41,0.00414965,-0.174537,46.3,1.8931235443669088,5.575176859287649,2.48072783160729e-10,0.6023351337036517,648.0777692460064,-5.2558314355313716,-0.4307,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-195-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,195.0,177.7,1.2766400000000002,1.58,0.808,72.0,5.71,45.2,5.35,36.46,0.00255808,-0.14283200000000001,45.1,1.8074395967137113,5.7170826506724515,7.755944504161635e-11,0.6301950965784864,508.06038826379876,5.967563649207757,-0.4214,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-200-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,200.0,182.4,1.2766400000000002,1.58,0.808,72.0,5.84,45.3,5.47,36.58,0.00261632,-0.143148,45.1,1.812831044357512,5.84738907189142,8.08223172821989e-11,0.6090854850512806,481.39462199605674,6.128829801867491,-0.4214,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-205-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,205.0,187.0,1.2766400000000002,1.58,0.808,72.0,5.98,45.4,5.6,36.7,0.00267904,-0.143464,45.1,1.8181057376775807,5.987632050531099,8.418992759939261e-11,0.5879109301004102,460.6504604599316,6.276472435532651,-0.4214,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-210-5MB,Seraphim Solar System CoLtd,Mono-c-Si,0,210.0,191.7,1.2766400000000002,1.58,0.808,72.0,5.91,45.7,5.62,37.4,0.00264768,-0.144412,45.1,1.8293326634613045,5.917423299472142,8.369062131817398e-11,0.5034070003710722,999999.6834410509,6.266267076666836,-0.4214,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-220-6PC,Seraphim Solar System CoLtd,Multi-c-Si,0,220.0,198.0,1.470144,1.482,0.992,54.0,8.74,33.3,8.19,27.0,0.004422440000000001,-0.10509479999999999,47.5,1.3430828361390426,8.750086432378072,1.470321317637122e-10,0.2814415247781428,243.8720672033465,7.874873848714313,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-225-6PC,Seraphim Solar System CoLtd,Multi-c-Si,0,225.0,202.7,1.470144,1.482,0.992,54.0,8.92,33.4,8.35,27.2,0.00451352,-0.1054104,47.5,1.3511533137412537,8.930755480923613,1.613204254202386e-10,0.2598426227351412,215.49909353528417,8.511390646629819,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-230-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,230.0,207.0,1.6268799999999999,1.64,0.992,60.0,8.32,36.6,7.79,29.52,0.008128640000000001,-0.14782740000000003,46.8,1.5746320412058092,8.327312762496973,6.617856246498182e-10,0.32133715704344695,365.59730024749587,-5.151202781862701,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-230-6PC,Seraphim Solar System CoLtd,Multi-c-Si,0,230.0,207.3,1.470144,1.482,0.992,54.0,9.03,33.5,8.46,27.2,0.004569179999999999,-0.105726,47.5,1.3523471931553988,9.040485996771753,1.552210330035401e-10,0.2687842795183511,231.4631897661468,8.063761059226014,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-235-6MC,Seraphim Solar System CoLtd,Mono-c-Si,0,235.0,210.3,1.470144,1.482,0.992,54.0,9.01,34.3,8.46,27.8,0.00455906,-0.1082508,49.1,1.3816841816635066,9.018725502958992,1.4729514102772387e-10,0.2827837761467017,292.0040327716742,7.618481078212231,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-235-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,235.0,211.6,1.6268799999999999,1.64,0.992,60.0,8.48,36.7,7.94,29.6,0.00828496,-0.1482313,46.8,1.5788909029002611,8.48743506111708,6.741026394004979e-10,0.31623603706707587,360.6806504749414,-5.155965549763857,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-235-6PC,Seraphim Solar System CoLtd,Multi-c-Si,0,235.0,211.9,1.470144,1.482,0.992,54.0,9.2,33.6,8.62,27.3,0.0046552,-0.1060416,47.5,1.356847787884015,9.210556021889008,1.5949153071297915e-10,0.2620502539458326,228.38741153418536,8.137665044540997,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-240-6MC,Seraphim Solar System CoLtd,Mono-c-Si,0,240.0,214.9,1.470144,1.482,0.992,54.0,9.18,34.4,8.61,27.9,0.004645079999999999,-0.1085664,49.1,1.3870351181125955,9.189810345746542,1.5345385159233629e-10,0.2757340185628265,258.01725667783097,7.816267781168538,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-240-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,240.0,216.2,1.6268799999999999,1.64,0.992,60.0,8.6,36.9,8.05,29.8,0.008402199999999999,-0.14903909999999998,46.8,1.5890476530700537,8.607722915428685,6.98991164020519e-10,0.3077736301191995,342.7273277812378,-4.983025764712085,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-240-6PC,Seraphim Solar System CoLtd,Multi-c-Si,0,240.0,216.6,1.470144,1.482,0.992,54.0,9.37,33.7,8.77,27.4,0.004741219999999999,-0.1063572,47.5,1.3621556948920115,9.38157790738833,1.660099295694052e-10,0.2555024692133421,206.7781526527543,8.331628302604008,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-245-6MC,Seraphim Solar System CoLtd,Mono-c-Si,0,245.0,219.5,1.470144,1.482,0.992,54.0,9.25,34.5,8.75,28.0,0.0046805,-0.108882,49.1,1.3855407390016181,9.252544942310855,1.4147432565993698e-10,0.2722097149590231,989.3900440173965,7.014734066499099,-0.422,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-245-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,245.0,222.3,1.6268799999999999,1.64,0.992,60.0,8.76,37.0,8.21,29.86,0.00435372,-0.115995,45.6,1.4945179991801527,8.770067035892572,1.5300006566235148e-10,0.33043519235652974,287.53375522613965,8.938473660835191,-0.4272,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-250-6MC,Seraphim Solar System CoLtd,Mono-c-Si,0,250.0,224.1,1.470144,1.482,0.992,54.0,9.3,34.6,8.9,28.1,0.0047058000000000004,-0.1091976,49.1,1.3934490948648892,9.300002211420432,1.5301854519725578e-10,0.23771811850661687,999978.6740269446,7.634896186552625,-0.422,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-250-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,250.0,227.0,1.6268799999999999,1.64,0.992,60.0,8.92,37.1,8.35,29.9,0.00443324,-0.1163085,45.6,1.4983316785012166,8.931403613472002,1.5501971446241462e-10,0.3310838643043674,258.9765419150067,8.898691664919156,-0.4272,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-255-6MC,Seraphim Solar System CoLtd,Mono-c-Si,0,255.0,228.7,1.470144,1.482,0.992,54.0,9.35,34.7,8.98,28.4,0.0047311,-0.1095132,49.13,1.4051768114525056,9.350170683266922,1.7620836739666348e-10,0.19511822725890177,10688.572112961405,8.819654582676101,-0.422,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-255-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,255.0,231.7,1.6268799999999999,1.64,0.992,60.0,9.02,37.2,8.45,30.19,0.00448294,-0.11662200000000002,45.6,1.5076512249439176,9.03036007735529,1.7097751629426868e-10,0.29920884464014746,260.50616306808325,9.663199828686805,-0.4272,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-260-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,260.0,231.8,1.6268799999999999,1.64,0.992,60.0,9.1,37.6,8.53,30.5,0.0045227,-0.117876,50.1,1.5086922168577812,9.110477303678762,1.3462779977104088e-10,0.30532510034574745,265.18832399468425,7.49492555661512,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-260-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,260.0,236.3,1.6268799999999999,1.64,0.992,60.0,9.17,37.3,8.59,30.3,0.00455749,-0.1169355,45.6,1.5125580260868043,9.180506122554469,1.7622750539923453e-10,0.29116193298931664,254.13325402304554,9.785392207558736,-0.4272,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-265-5MA,Seraphim Solar System CoLtd,Mono-c-Si,0,265.0,237.2,1.6811200000000002,1.58,1.064,96.0,5.68,60.5,5.45,48.7,0.00264688,-0.19136150000000002,49.5,2.3959075278954973,5.680282001876283,6.130885833107328e-11,0.7495541291549875,15097.31777713515,3.8601824635358213,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-265-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,265.0,236.4,1.6268799999999999,1.64,0.992,60.0,9.13,37.7,8.36,30.6,0.00453761,-0.11818950000000002,50.1,1.53211041347338,9.159923350669489,1.800867412913453e-10,0.30107386974120987,91.86152126033303,10.10397357648245,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-265-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,265.0,241.0,1.6268799999999999,1.64,0.992,60.0,9.32,37.4,8.72,30.4,0.0046320400000000005,-0.117249,45.6,1.5180883210919365,9.331627093688887,1.8317852496485015e-10,0.2846499578532141,228.16861390001694,9.989167950241471,-0.4272,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-270-5MA,Seraphim Solar System CoLtd,Mono-c-Si,0,270.0,241.9,1.6811200000000002,1.58,1.064,96.0,5.78,60.6,5.53,48.9,0.0026934800000000003,-0.1916778,49.5,2.398125923667488,5.780004356512064,6.129405247017065e-11,0.753664852668399,999996.8959440935,3.71022211159542,-0.412,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-270-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,270.0,241.0,1.6268799999999999,1.64,0.992,60.0,9.26,37.8,8.8,30.7,0.004602220000000001,-0.118503,50.1,1.5081573214481838,9.272513909344603,1.208286386054681e-10,0.2966481410299834,999999.9792833356,6.355403777368121,-0.418,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-270-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,270.0,243.4,1.63,,,60.0,8.94,38.5,8.63,31.3,0.0038263199999999994,-0.096635,46.5,1.5698292865371875,8.940175935112114,1.9958366188811062e-10,0.2212182582784094,11241.058352292388,39.02543511505942,-0.4475,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-275-5MA,Seraphim Solar System CoLtd,Mono-c-Si,0,275.0,246.5,1.6811200000000002,1.58,1.064,96.0,5.87,60.8,5.57,49.4,0.00273542,-0.19231040000000002,49.5,2.405874602744797,5.870323636766408,6.209723767201007e-11,0.757296913745076,13735.576072688746,3.6921599807388814,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-275-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,275.0,245.6,1.6268799999999999,1.64,0.992,60.0,9.45,38.1,8.81,31.2,0.00469665,-0.11944350000000001,50.1,1.5412504595785352,9.464124052096132,1.6982877631433775e-10,0.2584999292828407,172.95492973762632,9.217853484112739,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-275-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,275.0,247.5,1.9403519999999999,1.956,0.992,72.0,8.25,44.0,7.72,35.6,0.00806025,-0.17771599999999999,46.8,1.8973340501741416,8.25755588384575,6.91264147761171e-10,0.3723280404305921,406.53185271365857,-4.745651865540992,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-275-6PB,Seraphim Solar System CoLtd,Multi-c-Si,0,275.0,248.0,1.63,,,60.0,9.02,38.8,8.71,31.6,0.00386056,-0.09738799999999999,46.5,1.5835113760796293,9.020170407283803,2.0594178059381358e-10,0.21225572511590926,11235.153809090256,39.277043364395674,-0.4475,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-280-5MA,Seraphim Solar System CoLtd,Mono-c-Si,0,280.0,251.1,1.6811200000000002,1.58,1.064,96.0,5.98,60.8,5.66,49.6,0.0027866800000000006,-0.19231040000000002,49.5,2.4142706436679267,5.981833412842217,6.883481684662233e-11,0.7019286612103738,2289.4647819711377,4.4107878771016855,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-280-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,280.0,250.2,1.6268799999999999,1.64,0.992,60.0,9.5,38.2,8.95,31.3,0.0047215,-0.11975700000000002,50.1,1.537350376231761,9.506218533806862,1.5212578697049377e-10,0.25637323684724744,391.65919575926375,8.167208770079757,-0.418,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-280-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,280.0,252.1,1.9403519999999999,1.956,0.992,72.0,8.4,44.1,7.87,35.6,0.0082068,-0.1781199,46.8,1.897636627090865,8.406853861321348,6.713391806318613e-10,0.37890176450086893,464.37708856277874,-5.115701814810577,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-285-5MA,Seraphim Solar System CoLtd,Mono-c-Si,0,285.0,255.7,1.6811200000000002,1.58,1.064,96.0,6.07,60.9,5.73,49.8,0.0028286200000000004,-0.1926267,49.5,2.424662027525553,6.073250248735315,7.443633842900114e-11,0.6681880363396688,1247.8742719188197,4.955333455148353,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-285-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,285.0,258.3,1.63,,,60.0,9.33,39.1,9.05,31.5,0.00320019,-0.0909466,45.8,1.5740518527135967,9.3301937039902,1.519489982626309e-10,0.22822842877970362,10992.938195990244,46.42334610853445,-0.446,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-285-6MB-BB,Seraphim Solar System CoLtd,Mono-c-Si,0,285.0,260.1,1.57464,,,60.0,9.33,39.1,9.05,31.5,0.0035454,-0.111826,46.9,1.515688561193771,9.330229958700073,5.838228523233389e-11,0.25076950765846345,10174.355991857163,10.103083122892194,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-285-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,285.0,256.7,1.9403519999999999,1.956,0.992,72.0,8.53,44.2,7.99,35.68,0.00833381,-0.1785238,46.8,1.9021566754249803,8.537136585616029,6.833567649569145e-10,0.37405718651415143,447.09180309791435,-5.096705180956404,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-290-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,290.0,260.3,1.9403519999999999,1.956,0.992,72.0,8.55,44.9,8.02,36.2,0.0042579,-0.1397737,48.5,1.788102738032007,8.559817223640806,1.0493270262040098e-10,0.4222423478080745,367.7386214746754,6.636774688011193,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-290-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,290.0,263.0,1.63,,,60.0,9.44,39.3,9.15,31.7,0.0032379199999999996,-0.09141179999999999,45.8,1.5824050550883715,9.44016266366211,1.5448003026011534e-10,0.22689191673100725,13167.31508026469,46.479530356157795,-0.446,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-290-6MB-BB,Seraphim Solar System CoLtd,Mono-c-Si,0,290.0,264.8,1.57464,,,60.0,9.44,39.3,9.15,31.7,0.0035872,-0.11239799999999998,46.9,1.523759640303815,9.440221734226173,5.939074408674292e-11,0.2489404572109559,10598.274542250578,10.150915396246328,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-290-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,290.0,261.3,1.9403519999999999,1.956,0.992,72.0,8.65,44.3,8.1,35.8,0.00845105,-0.1789277,46.8,1.9080873133802372,8.65743187173207,7.064958591024441e-10,0.36389748948351364,423.54263220891875,-4.945978022081889,-0.431,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-295-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,295.0,264.9,1.9403519999999999,1.956,0.992,72.0,8.68,44.7,8.13,36.3,0.00432264,-0.13915110000000003,48.5,1.788630250937804,8.690716907614002,1.1970974024984597e-10,0.3763930366664511,304.85396223586184,7.652262730672158,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-295-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,295.0,267.7,1.63,,,60.0,9.56,39.5,9.25,31.9,0.0032790799999999998,-0.091877,45.8,1.5902218077020998,9.56019892604367,1.5585944710264607e-10,0.23062203915917054,11083.273946162628,46.43574152015989,-0.446,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-295-6MB-BB,Seraphim Solar System CoLtd,Mono-c-Si,0,295.0,269.5,1.57464,,,60.0,9.56,39.5,9.25,31.9,0.0036328000000000003,-0.11297,46.9,1.53112812831877,9.560215968763346,5.975723240990863e-11,0.25259704169645414,11181.386606036614,10.093405574666068,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-295-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,295.0,264.4,1.9403519999999999,1.956,0.992,72.0,8.78,44.4,8.22,35.9,0.004890459999999999,-0.1404816,48.6,1.7920272220831568,8.79100628452013,1.5018142158508773e-10,0.3869593988745454,308.68763067460776,7.684228255546014,-0.4192,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-300-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,300.0,269.5,1.9403519999999999,1.956,0.992,72.0,8.8,44.8,8.25,36.4,0.0043824,-0.1394624,48.5,1.7922964956429612,8.810079152653584,1.2092422253473383e-10,0.369474695191696,322.5844105900939,7.617417076272743,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-300-6MB,Seraphim Solar System CoLtd,Mono-c-Si,0,300.0,272.4,1.63,,,60.0,9.65,39.7,9.35,32.1,0.00330995,-0.0923422,45.8,1.6000020283625618,9.65018925167905,1.6160558558799808e-10,0.2172803102024985,11079.213721033906,46.75196200673353,-0.446,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-300-6MB-BB,Seraphim Solar System CoLtd,Mono-c-Si,0,300.0,274.2,1.57464,,,60.0,9.65,39.7,9.35,32.1,0.003667,-0.11354199999999999,46.9,1.5406373046397992,9.650210098162932,6.212010419792156e-11,0.2393651535818492,10994.270664608728,10.354283226795646,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-300-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,300.0,269.0,1.9403519999999999,1.956,0.992,72.0,8.92,44.5,8.36,35.9,0.00496844,-0.140798,48.6,1.7928115422488322,8.930393726102889,1.460945699146047e-10,0.39314165038511967,337.39813678380887,7.30305999582187,-0.4192,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-305-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,305.0,274.1,1.9403519999999999,1.956,0.992,72.0,8.93,44.9,8.36,36.5,0.00444714,-0.1397737,48.5,1.7981230855488413,8.941336024201432,1.2564591773823969e-10,0.3621990623193756,285.3238247204849,7.828205569769894,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-305-6MB-BB,Seraphim Solar System CoLtd,Mono-c-Si,0,305.0,278.9,1.57464,,,60.0,9.76,39.9,9.45,32.3,0.0037088,-0.114114,46.9,1.5487304522504342,9.760207468219264,6.3176454416697e-11,0.23743332949701018,11169.670730560303,10.403348886619266,-0.4,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-305-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,305.0,273.7,1.9403519999999999,1.956,0.992,72.0,9.06,44.6,8.48,36.0,0.00504642,-0.1411144,48.6,1.7986021024212409,9.071714770714177,1.5179143261943578e-10,0.38522671685440374,297.9276683128399,7.504587741418589,-0.4192,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-310-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,310.0,278.8,1.9403519999999999,1.956,0.992,72.0,9.0,45.0,8.43,36.8,0.004482,-0.14008500000000002,48.5,1.8076153727982391,9.010412167290577,1.365995128401393e-10,0.32984663830093097,285.1106618004785,8.488884823668524,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-310-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,310.0,278.3,1.9403519999999999,1.956,0.992,72.0,9.13,44.7,8.54,36.3,0.00508541,-0.14143080000000002,48.6,1.8093898394995294,9.141822441533657,1.675562251155009e-10,0.35296034512584423,272.5772137524966,8.302382669817364,-0.4192,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-315-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,315.0,283.4,1.9403519999999999,1.956,0.992,72.0,9.08,45.2,8.55,36.9,0.00452184,-0.14070760000000002,48.5,1.8089815439779509,9.086609181076641,1.2654577058709771e-10,0.3375738791539988,463.7746667856092,7.724792647617289,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-315-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,315.0,282.9,1.9403519999999999,1.956,0.992,72.0,9.25,44.8,8.66,36.4,0.00515225,-0.1417472,48.6,1.8131194491378932,9.26117902751088,1.6919436495107673e-10,0.3466728516364251,286.85179551779476,8.270184601128763,-0.4192,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-320-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,320.0,288.0,1.9403519999999999,1.956,0.992,72.0,9.08,45.2,8.43,38.0,0.00452184,-0.14070760000000002,48.5,1.852733334304081,9.09025228811505,2.23807174910739e-10,0.18362784999185036,162.6311036440389,12.85938719675863,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-320-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,320.0,287.5,1.9403519999999999,1.956,0.992,72.0,9.38,44.9,8.78,36.4,0.005224660000000001,-0.1420636,48.6,1.8150752221058193,9.391708382680715,1.6675990573162429e-10,0.35347886963164715,283.1844614023588,8.021858879788567,-0.4192,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-325-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,325.0,292.7,1.9403519999999999,1.956,0.992,72.0,9.2,45.3,8.54,38.1,0.0045816,-0.1410189,48.5,1.8574390539414192,9.210336130915877,2.2852492873337588e-10,0.17940870730289132,159.68839528724138,12.930598657619631,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-325-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,325.0,294.5,1.94,,,72.0,9.03,45.7,8.72,37.3,0.0037023,-0.1396135,45.4,1.8898297028608513,9.030149008721171,2.840513286898193e-10,0.230773956495548,13985.065871157225,17.29284527353858,-0.4501,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-330-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,330.0,297.3,1.9403519999999999,1.956,0.992,72.0,9.48,45.6,8.62,38.3,0.00472104,-0.14195280000000002,48.5,1.8902696382296782,9.4991975609143,2.9943378108309024e-10,0.17607499619770806,86.94807680606965,15.222693295895821,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-330-6PA,Seraphim Solar System CoLtd,Multi-c-Si,0,330.0,299.2,1.94,,,72.0,9.12,45.9,8.8,37.5,0.0037392,-0.1402245,45.4,1.8982822465743174,9.12015041776488,2.875485019844739e-10,0.23018350551565853,13956.340949540287,17.31474338558373,-0.4501,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-335-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,335.0,302.0,1.9403519999999999,1.956,0.992,72.0,9.6,45.7,8.73,38.4,0.0047808,-0.1422641,48.5,1.89476092895099,9.619167783020874,3.0458723884136717e-10,0.17213661543143519,86.2129721985891,15.264212537448204,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-340-6MA,Seraphim Solar System CoLtd,Mono-c-Si,0,340.0,306.6,1.9403519999999999,1.956,0.992,72.0,9.72,45.8,8.84,38.5,0.00484056,-0.1425754,48.5,1.899254269103775,9.739134146270045,3.0978172813696395e-10,0.1682954458447156,85.4928015444984,15.30577799891123,-0.4146,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-345-6MA,Seraphim Solar System CoLtd,Multi-c-Si,0,345.0,315.4,1.87598,1.934,0.97,72.0,9.43,46.8,9.11,37.9,0.0036777,-0.13384799999999997,46.51,1.8209661394503225,9.430237094575823,6.496716353866524e-11,0.29874745034551614,11882.141333915337,10.946379372799788,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-350-6MA,Seraphim Solar System CoLtd,Multi-c-Si,0,350.0,320.1,1.87598,1.934,0.97,72.0,9.51,47.0,9.19,38.1,0.0037089000000000002,-0.13441999999999998,46.51,1.8297944323747397,9.510233127304982,6.648842768709137e-11,0.2911939366403875,11878.733316170052,11.07767698535787,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-355-6MA,Seraphim Solar System CoLtd,Multi-c-Si,0,355.0,324.8,1.87598,1.934,0.97,72.0,9.61,47.2,9.27,38.3,0.0037478999999999998,-0.134992,46.51,1.836934987948522,9.610240450450112,6.658367892174118e-11,0.29610209952812727,11834.222163138505,10.996996574642735,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-360-6MA,Seraphim Solar System CoLtd,Multi-c-Si,0,360.0,329.5,1.87598,1.934,0.97,72.0,9.7,47.4,9.36,38.5,0.0037829999999999995,-0.135564,46.51,1.845795103288506,9.700236375607496,6.822206500015774e-11,0.2882336580145369,11828.078730786316,11.13093345788881,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-395-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,395.0,367.4,1.94,,,54.0,13.69,36.75,12.81,30.85,0.00180708,-0.09602775,46.5,1.3121225029868948,13.709227304060112,9.143951691767265e-12,0.13663279715243407,97.28368526116247,1.0489411658993848,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-400-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,400.0,372.1,1.94,,,54.0,13.78,37.0,12.89,31.05,0.00181896,-0.09668099999999999,46.5,1.3210506211300739,13.799737725659087,9.201212428411862e-12,0.13751489384014745,96.00676761336968,1.0477990786942923,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-405-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,405.0,376.9,1.94,,,54.0,13.86,37.25,12.97,31.24,0.00182952,-0.09733425,46.5,1.329306348514391,13.879734181780059,9.129640693345562e-12,0.13941735236935793,97.91763914488635,0.9341917131941817,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-410-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,410.0,381.7,1.94,,,54.0,13.94,37.5,13.05,31.43,0.00184008,-0.09798749999999999,46.5,1.3375627175849438,13.959719935905879,9.059968815742314e-12,0.14129637622054225,99.88224574142727,0.8222076232453808,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-415-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,415.0,386.5,1.94,,,54.0,14.02,37.75,13.13,31.64,0.00185064,-0.09864074999999999,46.5,1.3462376379338323,14.039486155475414,9.070252209252827e-12,0.14141174359780792,101.74365340608901,0.782839306134656,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-420-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,420.0,391.3,1.94,,,54.0,14.09,38.0,13.21,31.81,0.00185988,-0.099294,46.5,1.3536175572601852,14.109001699487091,8.8424758369414e-12,0.14513209273487943,107.61727872724069,0.5285939236451005,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-425-BMD-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,425.0,396.1,1.94,,,54.0,14.17,38.25,13.29,32.0,0.00187044,-0.09994724999999999,46.5,1.3618765434338256,14.188948096915762,8.77933190719228e-12,0.14694222370082344,109.8881498544286,0.4218593454385789,-0.3392,N,2025.7.3,6/23/2025,4.0,bootstrapping +Seraphim Solar System CoLtd SRP-430-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,430.0,405.9,1.95,,,54.0,13.99,38.9,13.32,32.3,0.0061416100000000005,-0.0916873,46.23,1.3221922621804452,13.99663116269239,2.3203232226405988e-12,0.1812016514788551,382.2876023859293,-0.5583291483506189,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-435-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,435.0,410.7,1.95,,,54.0,14.07,39.1,13.39,32.5,0.006176730000000001,-0.0921587,46.23,1.3298991256373114,14.077160418646445,2.3794884844655517e-12,0.1782185659824877,350.1939612757381,-0.39469140063932545,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-440-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,440.0,415.6,1.95,,,54.0,14.15,39.3,13.47,32.7,0.0062118500000000005,-0.09263009999999999,46.23,1.337173412531316,14.156852043628987,2.4185464631540272e-12,0.17527497593321695,361.9564030235114,-0.30771053898725614,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-440-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,440.0,412.7,1.99,,,48.0,15.8,35.38,14.97,29.41,0.008216,-0.10691836000000003,45.58,1.2928998746390896,15.809200151793187,2.04242415528518e-11,0.13032605029250485,223.81713444964248,-8.441047792644891,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-445-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,445.0,420.4,1.95,,,54.0,14.23,39.5,13.54,32.9,0.006246970000000001,-0.0931015,46.23,1.344880770715307,14.237353784423657,2.4791195981453906e-12,0.1723559401554322,333.51875597124234,-0.14690546236389218,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-445-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,445.0,417.6,1.99,,,48.0,15.85,35.58,15.03,29.61,0.008242,-0.10752276000000001,45.58,1.3004443927346692,15.85820594828293,2.06088629919017e-11,0.12810336771463943,247.43494939710342,-8.400223607363127,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-450-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,450.0,425.2,1.95,,,54.0,14.31,39.7,13.6,33.1,0.006282090000000001,-0.0935729,46.23,1.3530253331975255,14.318623414293002,2.562594008642574e-12,0.16945314244170936,281.1965642439111,0.0873310415328131,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-450-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,450.0,422.4,1.99,,,48.0,15.9,35.78,15.1,29.81,0.008268,-0.10812716000000001,45.58,1.3075621284914691,15.906523781609192,2.0624796040322032e-11,0.1259298754768293,306.9209184116204,-8.422999203050342,-0.3241,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-455-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,455.0,430.1,1.95,,,54.0,14.39,39.9,13.67,33.3,0.00631721,-0.0940443,46.23,1.3607358954975577,14.399070733556538,2.6255107871880526e-12,0.16659104097319466,264.28348578100383,0.24510755635802547,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-455-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,455.0,427.2,1.99,,,48.0,15.95,35.98,15.17,30.01,0.008294,-0.10873155999999999,45.58,1.3146761059871963,15.954906630647187,2.0639557059622845e-11,0.12377792428621995,402.36530181410484,-8.446110258446428,-0.3241,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-460-BTD-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,460.0,434.9,1.95,,,54.0,14.47,40.1,13.73,33.5,0.0063523300000000015,-0.09451570000000001,46.23,1.368887510760458,14.480258960885218,2.712534339510138e-12,0.16373893137050502,230.94954463179863,0.4762732590555106,-0.2838,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-460-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,460.0,432.0,1.99,,,48.0,16.0,36.18,15.23,30.21,0.00832,-0.10933596000000001,45.58,1.3222082429021609,16.004047051273556,2.0818359607780285e-11,0.12161477168135941,480.80346930220753,-8.407817142830142,-0.3241,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-465-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,465.0,436.9,1.99,,,48.0,16.05,36.38,15.3,30.41,0.008346,-0.10994036000000001,45.58,1.3293142789863137,16.052540880111685,2.0829868000278313e-11,0.11950381929814251,754.8708578794631,-8.431973634979634,-0.3241,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-470-BTE-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,470.0,441.7,1.99,,,48.0,16.1,36.58,15.36,30.61,0.008372,-0.11054476000000002,45.58,1.3368375646865314,16.10176084772316,2.100468809944303e-11,0.11737864346208202,1073.230924473895,-8.395508787874464,-0.3241,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-530-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,530.0,493.5,2.56,,,72.0,13.72,49.32,12.83,41.32,0.006530720000000001,-0.13469292000000002,46.83,1.8164742634844435,13.7383876044763,2.1599264836198487e-11,0.18024031936472504,134.48718647393915,3.1401439632469894,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-530-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,530.0,493.9,2.56,,,72.0,13.72,49.32,12.83,41.32,0.007518560000000001,-0.12685104,45.98,1.8435203731245091,13.737430078389757,3.21899733211723e-11,0.17552995172614097,138.16753418340278,13.065279217742363,-0.3408,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-535-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,535.0,498.3,2.56,,,72.0,13.79,49.46,12.9,41.48,0.00656404,-0.13507526,46.83,1.822275779831856,13.807853349520622,2.1926179683199432e-11,0.17606941612454355,135.99673583055065,3.2222951241987987,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-535-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,535.0,498.7,2.56,,,72.0,13.79,49.46,12.9,41.48,0.00755692,-0.12721112,45.98,1.8494009277955488,13.80690874401961,3.266907890036086e-11,0.17136781063309314,139.75976691394933,13.153016546250864,-0.3408,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-540-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,540.0,503.0,2.56,,,72.0,13.86,49.6,12.97,41.64,0.006597360000000001,-0.1354576,46.83,1.8280774116171266,13.87732845661347,2.2256073157928147e-11,0.17194395685152125,137.5277269828492,3.3039888027267397,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-540-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,540.0,503.4,2.56,,,72.0,13.86,49.6,12.97,41.64,0.00759528,-0.1275712,45.98,1.8552820585703045,13.876396733526793,3.315265496158397e-11,0.1672509472864691,141.37560623768675,13.240324881937822,-0.3408,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-545-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,545.0,507.8,2.56,,,72.0,13.93,49.76,13.04,41.8,0.006630680000000001,-0.13589456,46.83,1.8342381436226003,13.946943280832908,2.246374198508946e-11,0.16941074748414428,139.28186287903324,3.3384415632012594,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-545-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,545.0,508.2,2.56,,,72.0,13.93,49.76,13.04,41.8,0.0076336400000000006,-0.12798272,45.98,1.8615313807887588,13.946020416956037,3.345859242101467e-11,0.1647260378748471,143.23183517824867,13.27715579614084,-0.3408,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-550-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,550.0,512.6,2.56,,,72.0,14.0,48.92,13.11,41.96,0.0066640000000000015,-0.13360052,46.83,1.8223493039406242,14.009571685136356,2.994678825467527e-11,0.09004677466119705,131.70667780344343,5.739782208230824,-0.3309,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-550-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,550.0,513.0,2.56,,,72.0,14.0,49.92,13.11,41.96,0.007672000000000001,-0.12839424,45.98,1.8677813312864908,14.01565025742969,3.376581954619327e-11,0.16222807269939793,145.1217681976989,13.313823800707038,-0.3408,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-555-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,555.0,517.4,2.56,,,72.0,14.07,50.08,13.18,42.12,0.006697320000000001,-0.13676848,46.83,1.8465615633966572,14.08619137132999,2.2881797727170127e-11,0.1644249790394149,142.88224364148664,3.4069027423382776,-0.3309,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-555-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,555.0,517.8,2.56,,,72.0,14.07,50.08,13.18,42.12,0.007710360000000001,-0.12880576,45.98,1.8740318909656966,14.085286169331933,3.407432713474321e-11,0.15975662483002562,147.04637075136037,13.35032813933794,-0.3408,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-560-BMA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,560.0,522.2,2.56,,,72.0,14.14,50.24,13.25,42.28,0.00673064,-0.13720544,46.83,1.8527241862944845,14.15582445415496,2.30921637201262e-11,0.16197157695765482,144.7303068984888,3.440906109575095,-0.3309,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-560-BMA-HV,Seraphim Solar System CoLtd,Mono-c-Si,1,560.0,522.6,2.56,,,72.0,14.14,50.24,13.25,42.28,0.00774872,-0.12921728000000002,45.98,1.8802830621605522,14.154928078122309,3.438411575124574e-11,0.15731127299496744,149.00654950515258,13.386670802588721,-0.3408,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-570-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,570.0,536.0,2.56,,,72.0,13.83,52.1,13.08,43.58,0.00607137,-0.1399927,46.65,1.823496443781076,13.84160160548333,5.323335339400087e-12,0.21047700022852736,250.90466345391926,-6.534791447559397,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-575-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,575.0,540.8,2.56,,,72.0,13.89,52.3,13.15,43.73,0.00609771,-0.1405301,46.65,1.829281236906521,13.900752576123354,5.252277429114854e-12,0.21193510858723535,273.7742676536017,-6.675404526075234,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-580-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,580.0,545.6,2.56,,,72.0,13.95,52.5,13.22,43.88,0.00612405,-0.1410675,46.65,1.8350714793529048,13.959888129474583,5.1830700869076156e-12,0.21337598810584527,301.0271055613608,-6.814325418662376,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-585-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,585.0,550.5,2.56,,,72.0,14.13,52.3,13.43,43.6,0.006203070000000001,-0.1405301,46.65,1.8233015828198993,14.137277814852492,4.8885330035683555e-12,0.21959151060902196,426.34061128780394,-7.372217208630047,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-590-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,590.0,555.3,2.56,,,72.0,14.07,52.9,13.46,44.17,0.006176730000000001,-0.1421423,46.65,1.840174765509076,14.070685264366583,4.604354905238835e-12,0.2174117192007317,4463.946274002385,-7.821192240939951,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-595-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,595.0,560.1,2.56,,,72.0,14.25,52.7,13.53,44.0,0.006255750000000001,-0.1416049,46.65,1.8394796688448314,14.258307473966722,5.097872419559627e-12,0.21375790647290074,366.6638243626883,-7.112017100241463,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-600-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,600.0,565.0,2.56,,,72.0,14.31,52.9,13.58,44.2,0.006282090000000001,-0.1421423,46.65,1.847571169246965,14.31879764098739,5.204791493854262e-12,0.21087275730729832,342.9998078029075,-6.983107625325117,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-605-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,605.0,569.8,2.56,,,72.0,14.37,53.1,13.63,44.4,0.00630843,-0.1426797,46.65,1.85566428303811,14.379271636728376,5.313222114250642e-12,0.20800840494589548,322.3897650032755,-6.854984166601543,-0.2973,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-610-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,610.0,574.6,2.56,,,72.0,14.43,53.3,13.68,44.6,0.006334770000000001,-0.1432171,46.65,1.8637589449208556,14.439729662554722,5.423169278029534e-12,0.20516463116689138,304.2783466052134,-6.727644020570455,-0.2973,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-610-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,610.0,575.8,2.7,,,66.0,15.87,48.92,14.99,40.71,0.006665400000000001,-0.12068564000000001,45.79,1.6883799605268737,15.886499631100596,4.075885924535648e-12,0.19124571869203824,183.94772207198164,-1.4525771301768264,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-615-BTA-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,615.0,579.5,2.56,,,72.0,14.49,53.5,13.73,44.8,0.0063611100000000005,-0.1437545,46.65,1.871855229475903,14.500171913133384,5.534649430286895e-12,0.20234119903862327,288.2372216776434,-6.601070322264801,-0.2973,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-615-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,615.0,580.7,2.7,,,66.0,15.92,49.12,15.04,40.91,0.0066864,-0.12117903999999999,45.79,1.6958038353985851,15.936175111118997,4.125882378975448e-12,0.18888897874075095,185.90985387950664,-1.3794133755507618,-0.2926,N,2025.7.3,6/23/2025,2.0,first_pass +Seraphim Solar System CoLtd SRP-620-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,620.0,585.5,2.7,,,66.0,15.97,49.32,15.09,41.11,0.0067074000000000005,-0.12167244,45.79,1.7032268523550198,15.985855215358558,4.1760636144761845e-12,0.18654833544120153,187.89886181350082,-1.3069591073295264,-0.2926,N,2025.7.3,6/23/2025,4.0,bootstrapping +Seraphim Solar System CoLtd SRP-625-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,625.0,590.3,2.7,,,66.0,16.02,49.52,15.14,41.31,0.006728400000000001,-0.12216584000000001,45.79,1.7106490512311272,16.035539914918303,4.226429647373712e-12,0.18422361858178773,189.9149591279987,-1.2351997264671175,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-630-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,630.0,595.2,2.7,,,66.0,16.07,49.72,15.19,41.51,0.006749400000000001,-0.12265923999999999,45.79,1.7180702800216416,16.085229024871445,4.276967437029817e-12,0.18191468685924467,191.96035377967291,-1.1641478066200595,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-635-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,635.0,600.0,2.7,,,66.0,16.12,49.92,15.23,41.71,0.006770400000000001,-0.12315264000000001,45.79,1.7260056595578377,16.13566869969845,4.361859731564186e-12,0.17959482609065278,184.7676351856575,-1.0266471071687964,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-640-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,640.0,604.9,2.7,,,66.0,16.17,50.12,15.27,41.91,0.006791400000000001,-0.12364604,45.79,1.7339433600410212,16.18609061078753,4.44788445442568e-12,0.1772866005803297,178.16131215125148,-0.8899376230159747,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-645-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,645.0,609.7,2.7,,,66.0,16.22,50.32,15.32,42.11,0.0068124,-0.12413943999999999,45.79,1.7413640894632298,16.235771307481276,4.49957669824833e-12,0.175020638941017,179.99996274035206,-0.8211675548443983,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Seraphim Solar System CoLtd SRP-650-BTC-BG,Seraphim Solar System CoLtd,Mono-c-Si,1,650.0,614.6,2.7,,,66.0,16.27,50.52,15.37,42.31,0.006833400000000001,-0.12463284000000002,45.79,1.7487839513407422,16.285456505705007,4.551437268938871e-12,0.17276986522077784,181.86294832417735,-0.7530564207171443,-0.2926,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-230,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,230.0,206.0,1.6268799999999999,1.64,0.992,60.0,8.35,37.2,7.74,29.8,0.00334,-0.11532000000000002,48.3,1.4800070201085418,8.371078454774606,9.86415525363109e-11,0.3885628686872141,153.92494833057367,6.923001241575518,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-235,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,235.0,210.6,1.6268799999999999,1.64,0.992,60.0,8.42,37.4,7.81,30.1,0.003368,-0.11594,48.3,1.4913493922343837,8.439821845502642,1.0533384741947008e-10,0.36636494290973215,155.62591950406068,7.416418049698343,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-240,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,240.0,215.2,1.6268799999999999,1.64,0.992,60.0,8.49,37.5,7.87,30.5,0.003396,-0.11624999999999999,48.3,1.5046972900484819,8.508407848040628,1.239002151082839e-10,0.3166514634604378,146.04482971940763,8.762761336531415,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-245,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,245.0,219.8,1.6268799999999999,1.64,0.992,60.0,8.57,37.7,7.96,30.8,0.003428,-0.11687000000000002,48.3,1.5149255873367518,8.586183836323146,1.299283129339821e-10,0.2952864861954766,156.36621902361026,9.090937588936658,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-250,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,250.0,224.4,1.6268799999999999,1.64,0.992,60.0,8.65,37.8,8.01,31.2,0.0034600000000000004,-0.11718,48.3,1.5302069430009266,8.66593836419315,1.5676228759101198e-10,0.24649269234083487,133.77544904945887,10.684717668715201,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-255,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,255.0,229.1,1.6268799999999999,1.64,0.992,60.0,8.73,37.9,8.06,31.6,0.0034920000000000003,-0.11749,48.3,1.5455613585517383,8.744741615725546,1.8867702530811816e-10,0.19831124753348806,117.44012793176668,12.28059035294912,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-260,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,260.0,233.7,1.6268799999999999,1.64,0.992,60.0,8.81,38.0,8.13,32.0,0.0035240000000000007,-0.1178,48.3,1.55881684343609,8.82178789802378,2.196357587046131e-10,0.15139831306833598,113.15157028542673,13.584803911385475,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-265,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,265.0,238.3,1.6268799999999999,1.64,0.992,60.0,8.89,38.1,8.18,32.4,0.003556,-0.11811,48.3,1.574254955993473,8.899120366808692,2.6299280940718276e-10,0.10454288346624852,101.90228914824496,15.176904105693815,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-270,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,270.0,242.9,1.6268799999999999,1.64,0.992,60.0,8.97,38.2,8.24,32.8,0.003588,-0.11842000000000001,48.3,1.5886281363725383,8.975491607984509,3.092751464804664e-10,0.05872646175578512,95.92388515370158,16.61773195537682,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT60-156P-275,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,275.0,247.6,1.6268799999999999,1.64,0.992,60.0,9.05,38.3,8.28,33.2,0.0036200000000000004,-0.11873,48.3,1.6053249647023553,9.051322727102528,3.743619470188662e-10,0.012531588393605958,85.74019319254204,18.363707942989926,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-275,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,275.0,248.3,1.9403519999999999,1.956,0.992,72.0,8.26,44.6,7.72,35.7,0.00413,-0.13826,47.2,1.7638412551316516,8.273397021946156,8.475718015050289e-11,0.4756340357006641,293.25452446923913,5.562489649284643,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-280,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,280.0,253.0,1.9403519999999999,1.956,0.992,72.0,8.34,44.8,7.78,36.0,0.00417,-0.13887999999999998,47.2,1.777299020515059,8.35490947735949,9.235623545676187e-11,0.45214268602148017,252.91765063106024,6.221497847447207,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-285,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,285.0,257.6,1.9403519999999999,1.956,0.992,72.0,8.43,45.0,7.83,36.4,0.004215,-0.1395,47.2,1.7958199738065121,8.447854269396178,1.0767060301114929e-10,0.41345553704590327,195.215509821717,7.4687639109170725,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-290,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,290.0,262.2,1.9403519999999999,1.956,0.992,72.0,8.52,45.2,7.88,36.8,0.00426,-0.14012,47.2,1.814451917092254,8.540014304779307,1.253341052221759e-10,0.3752200317596705,159.72949360591485,8.718036106710827,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-295,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,295.0,266.9,1.9403519999999999,1.956,0.992,72.0,8.61,45.4,7.93,37.2,0.004305,-0.14074,47.2,1.833192612131613,8.631408735490343,1.4567244164607798e-10,0.3374271135540733,135.70383573771772,9.969020947995524,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-300,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,300.0,271.5,1.9403519999999999,1.956,0.992,72.0,8.68,45.6,7.98,37.6,0.00434,-0.14136,47.2,1.849697167829168,8.700644031091425,1.6393502157887177e-10,0.301206103285567,126.64527724801933,10.958146178260154,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-305,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,305.0,276.2,1.9403519999999999,1.956,0.992,72.0,8.75,45.8,8.03,38.0,0.004375,-0.14198,47.2,1.8662290036455311,8.769528190679633,1.8418327082228718e-10,0.2654408997057717,118.93615562311544,11.941898759580388,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-310,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,310.0,280.8,1.9403519999999999,1.956,0.992,72.0,8.82,46.0,8.08,38.4,0.00441,-0.1426,47.2,1.8827871342254126,8.838074383529849,2.0659672042571828e-10,0.23012240177670093,112.29592412848577,12.920231174630409,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-315,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,315.0,285.5,1.9403519999999999,1.956,0.992,72.0,8.89,46.2,8.13,38.8,0.004445,-0.14322000000000001,47.2,1.8993706055630708,8.906295079200367,2.313673949461282e-10,0.19524178895723676,106.51679070121835,13.893100589976234,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-320,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,320.0,290.1,1.9403519999999999,1.956,0.992,72.0,8.96,46.4,8.19,39.1,0.0044800000000000005,-0.14384,47.2,1.9118296198173335,8.975036390412123,2.458769246224563e-10,0.1755255116186818,104.5934944374863,14.384355592670948,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical HT72-156P-325,Shanghai Aerospace Automobile Electromechanical,Multi-c-Si,0,325.0,294.8,1.9403519999999999,1.956,0.992,72.0,9.02,46.6,8.23,39.5,0.00451,-0.14446,47.2,1.9285592869046206,9.032815967277655,2.746791100142395e-10,0.14156703556771966,99.63623178141529,15.358960897877559,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156P(V)-260,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,260.0,238.4,1.63,,,60.0,8.97,37.6,8.32,31.3,0.00518466,-0.1106944,46.1,1.4844609562461495,8.984778169916373,8.685451206747807e-11,0.2107669603436128,127.93056742306119,10.632717581011192,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156P(V)-265,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,265.0,243.1,1.63,,,60.0,9.04,37.8,8.37,31.7,0.00522512,-0.1112832,46.1,1.4998399825656117,9.053576647999275,9.904043232762748e-11,0.17750510432935523,118.19163058947,11.751660553037151,-0.3799,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156P(V)-270,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,270.0,247.8,1.63,,,60.0,9.11,38.0,8.42,32.1,0.00526558,-0.111872,46.1,1.5152364451945712,9.121968003063985,1.1267908176685642e-10,0.1446479056198368,110.10545568448005,12.861510115954593,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156P(V)-275,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,275.0,252.5,1.63,,,60.0,9.18,38.2,8.47,32.5,0.00530604,-0.11246080000000001,46.1,1.5306495201231647,9.189971313347964,1.2791050302886458e-10,0.11218730510973365,103.28423525047243,13.962283084577253,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-280,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,280.0,256.1,1.63,,,60.0,9.32,38.6,8.65,32.4,0.00367208,-0.1042586,47.3,1.4935484972503679,9.333807386082182,5.383286308810157e-11,0.1817555935666915,122.6852161506395,15.983333711540855,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156P(V)-280,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,280.0,257.2,1.63,,,60.0,9.25,38.4,8.52,32.9,0.0053465,-0.1130496,46.1,1.546078416121185,9.257604389742264,1.4488463869491267e-10,0.0801155125562545,97.4527246689702,15.054001134512763,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-285,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,285.0,260.8,1.63,,,60.0,9.39,38.8,8.7,32.8,0.00369966,-0.1047988,47.3,1.5083259222522845,9.402356810821827,6.102370984658322e-11,0.15015534547350756,114.10377038874203,17.10091577104765,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-290,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,290.0,265.5,1.63,,,60.0,9.46,39.0,8.75,33.2,0.0037272400000000006,-0.105339,47.3,1.5231275567818252,9.470525781697125,6.904132060312946e-11,0.11892269891724865,106.8812533068898,18.210927721110334,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-295,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,295.0,270.2,1.63,,,60.0,9.64,39.7,9.12,32.4,0.00379816,-0.10722970000000001,47.3,1.4993161827951962,9.645558413261679,3.0291302490422016e-11,0.3008258574535284,521.7246763872829,10.332561165060683,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-300,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,300.0,274.9,1.63,,,60.0,9.71,39.9,9.16,32.8,0.00382574,-0.1077699,47.3,1.5145951776152005,9.717794323714537,3.477972265190286e-11,0.2702092775515807,336.62086150074254,11.520303186009684,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-305,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,305.0,285.0,1.63,,,60.0,9.78,40.1,9.21,33.2,0.00417606,-0.10935270000000001,42.91,1.5220525160674971,9.788798345964905,3.48442071172224e-11,0.24162169159592192,268.5800476149573,10.372723894449841,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-310,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,310.0,289.8,1.63,,,60.0,9.85,40.3,9.25,33.6,0.00420595,-0.10989809999999998,42.91,1.5373560798188193,9.859827373616806,3.989264971958631e-11,0.21157946710215553,212.06660666101604,11.535628293334005,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-310,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,310.0,282.6,1.94,,,72.0,8.98,45.2,8.29,37.4,0.00795628,-0.1440072,47.2,1.8524792455243106,8.997129886736065,2.1953079083416237e-10,0.26593986078399423,139.41364978768348,9.721504660095176,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-315,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,315.0,294.6,1.63,,,60.0,9.92,40.5,9.29,34.0,0.00423584,-0.1104435,42.91,1.5527173377832242,9.93023831202132,4.5598413933047114e-11,0.18178650381391837,176.13471163045983,12.695715529096164,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-315,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,315.0,287.3,1.94,,,72.0,9.05,45.4,8.34,37.8,0.0080183,-0.1446444,47.2,1.869109091579482,9.06614617038108,2.463125003380816e-10,0.2317111675800731,129.87513958721044,10.690538681647292,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-320,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,320.0,299.4,1.63,,,60.0,9.99,40.7,9.33,34.4,0.0042657300000000006,-0.1109889,42.91,1.5681352924644132,10.000053706509744,5.20364876136458e-11,0.15223884123779113,151.27416295481797,13.85287451202187,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-320,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,320.0,292.0,1.94,,,72.0,9.12,45.6,8.39,38.2,0.008080319999999998,-0.1452816,47.2,1.8857451036711148,9.134820409851635,2.7584445311527977e-10,0.1978994806558308,121.78093153521027,11.651879205863366,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-325,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,325.0,304.2,1.63,,,60.0,10.06,40.9,9.36,34.8,0.004295620000000001,-0.11153429999999999,42.91,1.5844989998108439,10.069658697475607,6.00794652202546e-11,0.12267720882388651,127.77424005008606,15.134660450593023,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-C-325,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,325.0,301.9,1.82,,,120.0,10.61,40.3,9.6,33.9,0.0051989,-0.11122800000000001,44.4,1.576069320133694,10.6377041567502,7.820771753971003e-11,0.15461685897665262,59.214395046071694,15.730135073175415,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-325,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,325.0,296.7,1.94,,,72.0,9.19,45.8,8.44,38.6,0.00814234,-0.1459188,47.2,1.9023865322477562,9.203165345383704,3.0835085562978374e-10,0.16449684882875643,114.82616214374859,12.605539173024196,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-C-330,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,330.0,306.7,1.82,,,120.0,10.74,40.4,9.69,34.1,0.005262600000000001,-0.111504,44.4,1.5854569964032466,10.766719954054347,8.615456209164804e-11,0.13860752865663697,55.7128527319092,16.536163787247347,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-330,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,330.0,301.4,1.94,,,72.0,9.26,46.0,8.49,38.9,0.00820436,-0.146556,47.2,1.916219031331843,9.272335188237093,3.32252215689351e-10,0.14527887275563767,109.06054879273822,13.228281965746536,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-C-335,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,335.0,311.4,1.82,,,120.0,10.87,40.5,9.78,34.3,0.0053263,-0.11178000000000002,44.4,1.511934871366508,10.900328551120518,2.350472518834169e-11,0.14211194358532359,50.934079335424684,4.8545944498375695,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-335,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,335.0,306.1,1.94,,,72.0,9.33,46.2,8.54,39.3,0.00826638,-0.1471932,47.2,1.9328750025379904,9.340128251141541,3.7027773179603597e-10,0.11258278764267804,103.70965547202684,14.168649832073225,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-156M(V)-C-340,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,340.0,316.2,1.82,,,120.0,11.0,40.6,9.87,34.5,0.00539,-0.11205600000000002,44.4,1.604249578959047,11.023677284551527,1.0423507016260044e-10,0.10745982002236422,49.923715400838645,18.139158395627764,-0.365,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-340,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,340.0,309.7,1.94,,,72.0,9.35,46.3,8.61,39.5,0.0065637,-0.1392241,47.8,1.8998084145184593,9.358499699948103,2.336629814861107e-10,0.10796823376463661,118.76925198978074,16.79523440867516,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156P(V)-340,Shanghai Aerospace Automobile Electromechanical Co Ltd,Multi-c-Si,0,340.0,310.7,1.94,,,72.0,9.49,46.8,8.86,38.4,0.00840814,-0.14910479999999998,47.2,1.8973954619832145,9.502697249412748,1.8044072065977676e-10,0.3055149508949097,228.3437096062971,7.465913772758023,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-345,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,345.0,314.4,1.94,,,72.0,9.42,46.5,8.65,39.9,0.00661284,-0.13982550000000002,47.8,1.9171953944370026,9.426529648875578,2.6351911822127103e-10,0.07566315262528764,109.15547283250477,17.880643037622118,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-350,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,350.0,327.8,1.82,,,120.0,11.33,40.7,10.53,33.3,0.0050985,-0.11803,44.6,1.4838589372380895,11.3575262160726,1.3453972853140894e-11,0.2670538787745567,109.92140904565863,-5.057437683757854,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-350 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,350.0,326.5,1.82169,,,120.0,11.33,40.7,10.53,33.3,0.0045320000000000004,-0.10500600000000002,44.3,1.5121568110209258,11.356121397646449,2.2498034807286433e-11,0.2611475025143881,113.27116797027658,11.409841117139045,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-350,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,350.0,319.1,1.94,,,72.0,9.62,47.3,9.16,38.3,0.00675324,-0.1422311,47.8,1.858495494423199,9.620003518013464,8.512892727941938e-11,0.3656479008027405,999999.9420192064,7.2537509413880805,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-355,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,355.0,332.6,1.82,,,120.0,11.43,40.9,10.61,33.5,0.0051435,-0.11860999999999998,44.6,1.4928993711301954,11.458675661849822,1.3994203519717094e-11,0.2620412588969227,104.4485603953615,-4.816220666462248,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-355 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,355.0,331.2,1.82169,,,120.0,11.43,40.9,10.61,33.5,0.004572,-0.10552199999999999,44.3,1.5213431783047429,11.457244100531051,2.3376282341611922e-11,0.25614267611721486,107.46219348959688,11.68211913838931,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-355,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,355.0,323.8,1.94,,,72.0,9.69,47.5,9.19,38.7,0.00680238,-0.14283250000000003,47.8,1.868352685234905,9.690008039919704,8.811468539566771e-11,0.3481703115919678,419650.7496868722,7.490245112029016,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-360,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,360.0,337.4,1.82,,,120.0,11.53,41.1,10.69,33.7,0.0051884999999999995,-0.11919,44.6,1.501940878497365,11.559777607120536,1.4550020471866711e-11,0.25710338106208663,99.5513836929859,-4.5771926917349965,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-360 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,360.0,336.0,1.82169,,,120.0,11.53,41.1,10.69,33.7,0.004612,-0.10603800000000001,44.3,1.5305305497247044,11.558319198982506,2.4278916285039434e-11,0.2512124989595198,102.27973357562011,11.951916862747979,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-360,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,360.0,328.5,1.94,,,72.0,9.76,47.7,9.23,39.1,0.006851520000000001,-0.14343390000000003,47.8,1.8878723917071514,9.76403273185919,1.0321252398474664e-10,0.3164985266731582,765.9884302571787,8.830078038024562,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-365,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,365.0,342.2,1.82,,,120.0,11.63,41.3,10.77,33.9,0.0052335,-0.11976999999999999,44.6,1.5109834285511539,11.660832695024482,1.5121668812329695e-11,0.2522385876006382,95.14363827290114,-4.340327416534512,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-166M-365 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,365.0,340.8,1.82169,,,120.0,11.63,41.3,10.77,33.9,0.004652000000000001,-0.106554,44.3,1.539718878445089,11.659347342308704,2.520628748886203e-11,0.2463553181314659,97.62766030336955,12.219263696400356,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-365,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,365.0,333.2,1.94,,,72.0,9.83,47.9,9.26,39.5,0.006900659999999999,-0.1440353,47.8,1.9057341386942825,9.836837496168725,1.179842401318684e-10,0.2855220209326598,410.48383169636617,9.96745510422436,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-370,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,370.0,337.9,1.94,,,72.0,9.9,48.1,9.3,39.9,0.0069498,-0.14463670000000003,47.8,1.9226185930305537,9.908243517152869,1.3301203391317262e-10,0.2548894407199848,306.107881732233,10.98823526593854,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-375,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,375.0,351.0,1.94,,,72.0,9.97,48.3,9.33,40.3,0.004646020000000001,-0.1268841,43.51,1.8161294597031221,9.98274913418413,2.7443994182099352e-11,0.2534728800781876,198.21930333861047,12.222316027437628,-0.3542,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-380,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,380.0,355.8,1.94,,,72.0,10.04,48.5,9.36,40.7,0.0046786399999999995,-0.12740949999999998,43.51,1.8325202445153979,10.05366257130559,3.127633504717151e-11,0.22349486422148462,164.23617479715216,13.370301155963462,-0.3542,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-385,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,385.0,360.6,1.94,,,72.0,10.11,48.7,9.39,41.1,0.00471126,-0.12793490000000002,43.51,1.8490030631949486,10.123917991666437,3.560953698080148e-11,0.19367629022741284,140.68605231000558,14.520673090560742,-0.3542,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-390,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,390.0,365.4,1.94,,,72.0,10.18,48.9,9.42,41.5,0.004743880000000001,-0.1284603,43.51,1.8655770915017913,10.193529952263246,4.0503854052144804e-11,0.16401510751369344,123.40574213123786,15.673293750877049,-0.3542,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-395,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,395.0,370.2,1.94,,,72.0,10.25,49.1,9.45,41.9,0.0047765,-0.1289857,43.51,1.8822415053580759,10.262512544197817,4.602606652812626e-11,0.13450933345252553,110.18707718988264,16.828027158988558,-0.3542,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-C-395,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,395.0,369.0,2.012016,,,144.0,10.67,48.6,9.76,40.5,0.0036278000000000005,-0.150174,43.8,1.849519553002343,10.699156717652503,3.929407428159901e-11,0.2403812743030083,87.9683462377832,-2.1719731532330986,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-400 {Blk},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,400.0,373.0,2.66,,,132.0,11.54,45.5,10.56,37.9,0.0043852,-0.13559,43.8,1.697937948900408,11.573138859817607,2.5255491558888684e-11,0.2169032924016287,75.53259268771265,-2.765036742574053,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-400 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,400.0,371.1,2.66,,,132.0,11.54,45.5,10.56,37.9,0.0046159999999999994,-0.11739000000000001,44.3,1.719726782252815,11.572057800571635,3.54847250071825e-11,0.21229561836273161,76.42107071530762,15.49817733593607,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-C-400,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,400.0,373.8,2.012016,,,144.0,10.79,48.7,9.84,40.7,0.0036686,-0.150483,43.8,1.8593180449173292,10.819693510924711,4.3081005766917616e-11,0.22391346179526284,81.36546292027155,-1.5205361809651987,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X-405,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,405.0,381.1,1.9,,,54.0,13.91,37.19,12.95,31.31,0.0061204,-0.10078490000000001,43.6,1.3799457946880738,13.930047518849024,2.662920885667712e-11,0.11950672316736298,82.91991329242555,5.676283140447226,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-405 {Blk},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,405.0,377.8,2.66,,,132.0,11.67,45.6,10.66,38.0,0.0044345999999999995,-0.135888,43.8,1.703684367724284,11.704549835106342,2.6305601587334545e-11,0.2129127652388367,71.91617467818318,-2.525806589536957,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-405 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,405.0,375.8,2.66,,,132.0,11.67,45.6,10.66,38.0,0.004668,-0.117648,44.3,1.7255033946831162,11.703432135376406,3.692051768349939e-11,0.20833856444078672,72.72377393743913,15.772114744800342,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-156M(V)-C-405,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,405.0,378.6,2.012016,,,144.0,10.91,48.8,9.91,40.9,0.0037094000000000003,-0.15079199999999998,43.8,1.8701806082769405,10.940488199948854,4.7837003835596505e-11,0.2074884369489293,74.2483598486602,-0.7589988432927852,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X-410,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,410.0,385.9,1.9,,,54.0,13.98,37.33,13.05,31.44,0.0061512,-0.1011643,43.6,1.3835495363247794,13.998043251134877,2.6027471952027138e-11,0.11855902177727475,91.86011531887785,5.426686034856076,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-410 {Blk},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,410.0,382.5,2.66,,,132.0,11.8,45.7,10.77,38.1,0.004484,-0.136186,43.8,1.7085664825113518,11.835245186784588,2.7053205052734995e-11,0.20912959096326084,70.01606189758532,-2.389012346580938,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-410 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,410.0,380.6,2.66,,,132.0,11.8,45.7,10.77,38.1,0.00472,-0.11790600000000001,44.3,1.730422441119032,11.8341057005031,3.7946255582253524e-11,0.2045921050934041,70.78543506424711,15.92867230084914,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-415,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,415.0,390.8,1.94,,,54.0,13.99,38.0,13.26,31.3,0.00602969,-0.0912,46.13,1.303216973415595,14.001757945447348,3.0038702685136143e-12,0.19627894077710184,233.53930318946357,-0.2095207872447483,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X-415,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,415.0,390.7,1.9,,,54.0,14.06,37.48,13.14,31.6,0.0061864,-0.1015708,43.6,1.3890555168996295,14.076902415586016,2.6182679697485797e-11,0.11553306619349223,96.10430574970242,5.424185166931576,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-415 {Blk},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,415.0,387.3,2.66,,,132.0,11.93,45.8,10.88,38.2,0.0045334,-0.136484,43.8,1.7134393063822213,11.96592274472498,2.781236425742846e-11,0.20542636808058962,68.22241997429536,-2.2539006285159813,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-415 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,415.0,385.3,2.66,,,132.0,11.93,45.8,10.88,38.2,0.004772,-0.11816399999999999,44.3,1.7353321474658814,11.964761514607272,3.898717714331384e-11,0.20092488069825973,68.95654179184938,16.08328625882384,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-420,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,420.0,395.6,1.94,,,54.0,14.07,38.1,13.34,31.5,0.006064170000000001,-0.09144,46.13,1.308767574817138,14.081162974994456,3.167271279206075e-12,0.1856315798283976,233.97314191631614,0.18185129946048154,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-420 {Blk},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,420.0,392.0,2.66,,,132.0,11.77,45.5,10.97,38.3,0.0044726,-0.13559,43.8,1.6911689554526017,11.78619304706243,2.362397674604981e-11,0.17278823713232508,125.5920241563612,-3.508486298826609,-0.341,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-166M-420 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,420.0,390.0,2.66,,,132.0,11.77,45.5,10.97,38.3,0.004708,-0.11739000000000001,44.3,1.7129756334781197,11.785464008675975,3.329230869321087e-11,0.16833464495029063,128.1232325899853,14.643233134751,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-425,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,425.0,400.5,1.94,,,54.0,14.15,38.2,13.42,31.7,0.006098650000000001,-0.09168000000000001,46.13,1.3143130264386662,14.160567614498259,3.337751921024712e-12,0.17511691169143115,234.4809516897516,0.5702510706187484,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-430,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,430.0,405.3,1.94,,,54.0,14.23,38.3,13.5,31.9,0.0061331300000000005,-0.09192,46.13,1.3198533908941568,14.239972547897718,3.515533729090286e-12,0.16473244589039757,235.05955881257475,0.9557124333421947,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-430,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,430.0,403.1,2.17,,,144.0,11.46,49.4,10.63,40.5,0.005157,-0.14326,44.6,1.8047077286797752,11.489178747849488,1.4350720430035574e-11,0.3115349000919827,122.35583186810325,-4.6386510240185554,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-430 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,430.0,401.4,2.173572,,,144.0,11.46,49.4,10.63,40.5,0.004584,-0.127452,44.3,1.8390679377029702,11.487738021785894,2.3952650115592965e-11,0.30441654315119687,125.77009398625016,11.882439309514655,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-435,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,435.0,410.1,1.94,,,54.0,14.31,38.4,13.6,32.0,0.0061676100000000005,-0.09215999999999999,46.13,1.3225803338923545,14.318091685980463,3.486985430714778e-12,0.16287953075366304,288.0494986928657,0.8331089005871618,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-435,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,435.0,402.3,2.161764,,,120.0,13.69,40.88,12.68,34.33,6.283709999999999,-0.10424400000000002,45.9,2.091037740871015,13.69434994976572,4.334175544068382e-08,0.045576748468864905,143.43794355206228,99.35719371079331,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-435 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,435.0,400.9,2.161764,,,120.0,13.69,40.88,12.68,34.33,0.0046546,-0.10424400000000002,46.0,1.587732290504406,13.711289579194698,8.693081072440649e-11,0.1286193715735635,82.70709316665084,23.911272768325222,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-435,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,435.0,407.9,2.17,,,144.0,11.53,49.6,10.7,40.7,0.0051884999999999995,-0.14384,44.6,1.8124320594389705,11.55855936722811,1.453661946618541e-11,0.30702360180732224,123.95170051473406,-4.587488976032579,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-435 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,435.0,406.2,2.173572,,,144.0,11.53,49.6,10.7,40.7,0.004612,-0.12796800000000003,44.3,1.8469286611550826,11.557131439482534,2.425629243475664e-11,0.299919759570255,127.4563720470795,11.93968949045567,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-440,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,440.0,415.0,1.94,,,54.0,14.39,38.6,13.68,32.2,0.0062020899999999995,-0.09264,46.13,1.3299432159380458,14.397769819814526,3.5438490703174266e-12,0.16005446994028721,296.4269291034879,0.9205999997824331,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-440,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,440.0,407.1,2.161764,,,120.0,13.76,41.03,12.77,34.48,6.31584,-0.1046265,45.9,2.098598866624806,13.76371191991654,4.362161098005385e-08,0.04361743570106011,161.6894401764568,99.35457112122394,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-440 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,440.0,405.7,2.161764,,,120.0,13.76,41.03,12.77,34.48,0.0046784,-0.1046265,46.0,1.592508503917124,13.779725318361653,8.610067159890404e-11,0.12652243747596295,88.25960234573081,23.75544924498116,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-440,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,440.0,412.7,2.17,,,144.0,11.6,49.8,10.77,40.9,0.00522,-0.14442,44.6,1.8201570425526488,11.627950579149475,1.4723650681775388e-11,0.3025711735422142,125.5725545143879,-4.536674148572452,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-440 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,440.0,411.0,2.173572,,,144.0,11.6,49.8,10.77,40.9,0.00464,-0.12848400000000001,44.3,1.8547900559161703,11.626535418463506,2.456171174862454e-11,0.29548166323842473,129.17027539031216,11.996551961613104,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-445,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,445.0,419.8,1.94,,,54.0,14.47,38.7,13.78,32.3,0.006236570000000001,-0.09288,46.13,1.3326805983915049,14.475957450041085,3.51596795916234e-12,0.15825686146251103,384.3887528627329,0.8007941597211241,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-445,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,445.0,411.8,2.161764,,,120.0,13.83,41.18,12.86,34.63,6.34797,-0.105009,45.9,2.1061604617698313,13.833115873327325,4.390129689229573e-08,0.041683520776852806,185.01575559093067,99.35198718811729,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-445 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,445.0,410.4,2.161764,,,120.0,13.83,41.18,12.86,34.63,0.0047022,-0.105009,46.0,1.5972973474576964,13.848203927952522,8.529979259407825e-11,0.12445118788061213,94.5488205902737,23.602626131934986,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-445,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,445.0,417.5,2.17,,,144.0,11.72,49.9,10.86,41.0,0.005274,-0.14470999999999998,44.6,1.8260215048349218,11.750061001105472,1.5340313025579577e-11,0.2980953992413331,116.21961880598715,-4.290526179392853,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-445 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,445.0,415.7,2.173572,,,144.0,11.72,49.9,10.86,41.0,0.004688,-0.128742,44.3,1.8607369719179185,11.748590698187956,2.556370073761062e-11,0.29104237903390423,119.30512070306027,12.274881095531793,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-450,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,450.0,424.6,1.94,,,54.0,14.55,38.9,13.85,32.5,0.006271050000000001,-0.09336,46.13,1.3404715513638008,14.556427070584999,3.603096754521492e-12,0.15547569651424675,351.9755043504127,0.9613857800426787,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-450,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,450.0,416.6,2.161764,,,120.0,13.9,41.33,12.95,34.78,6.3801000000000005,-0.1053915,45.9,2.113722528131938,13.902561054125886,4.418082024298252e-08,0.03977452803592756,215.87548284931296,99.3494410849077,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-450 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,450.0,415.2,2.161764,,,120.0,13.9,41.33,12.95,34.78,0.004726000000000001,-0.1053915,46.0,1.6020985224392423,13.916724689732655,8.452696654423158e-11,0.12240518133090703,101.73175490654243,23.452728354865144,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-450,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,450.0,422.3,2.17,,,144.0,11.83,50.0,10.96,41.1,0.0053235,-0.145,44.6,1.8302605034147752,11.86034955947689,1.5614962745243187e-11,0.29402872916613026,114.6098966890609,-4.224348473293722,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-166M-450 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,450.0,420.5,2.173572,,,144.0,11.83,50.0,10.96,41.1,0.004732,-0.129,44.3,1.8650468311825343,11.858866663963065,2.6013510685450927e-11,0.2870232213744862,117.62650263418949,12.349467620835577,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-455,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,455.0,429.5,1.94,,,54.0,14.63,39.1,13.92,32.69,0.00630553,-0.09384,46.13,1.3480704021974488,14.636890762497515,3.6763405538766486e-12,0.15353847828616904,325.98249382711055,1.0859165770181345,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-455,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,455.0,421.4,2.161764,,,120.0,13.97,41.48,13.04,34.93,6.412230000000001,-0.105774,45.9,2.1212850473170732,13.972046722144208,4.446018065490321e-08,0.0378899948064354,258.62156305455534,99.34693205890282,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-455 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,455.0,420.0,2.161764,,,120.0,13.97,41.48,13.04,34.93,0.004749800000000001,-0.105774,46.0,1.6069117202735783,13.985286889240268,8.378102417344027e-11,0.1203839890796524,110.01351018396086,23.305678579324606,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT54-18X(N)-460,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,460.0,434.3,1.94,,,54.0,14.71,39.3,13.99,32.89,0.00634001,-0.09431999999999999,46.13,1.355863324990596,14.717323378763417,3.7658349872297805e-12,0.1508084900705362,302.91931806259157,1.2437720633579568,-0.2927,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT60-18X-460,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,460.0,433.1,2.1,,,60.0,14.04,41.63,13.13,35.08,0.006177599999999999,-0.11281730000000002,43.6,1.5419198771514875,14.056595476375255,2.5740296925046654e-11,0.1302401867168516,110.18497972612332,5.2878143184437745,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-475,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,475.0,439.3,2.372502,,,132.0,13.58,44.8,12.64,37.26,0.004753,-0.11424,45.9,1.701184517583344,13.60251646283096,4.822823247051218e-11,0.18039352977579018,108.79791247684688,18.211683362678393,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-475 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,475.0,437.7,2.372502,,,132.0,13.58,44.8,12.64,37.26,0.0046172,-0.11424,46.0,1.7267950205300695,13.601416328995601,7.132229378600491e-11,0.17593904973541802,111.56217854616052,22.00415347662258,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-480,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,480.0,444.0,2.372502,,,132.0,13.65,44.95,12.72,37.77,0.0047775000000000005,-0.1146225,45.9,1.7149611503701072,13.667811046845598,5.490273962399098e-11,0.14522263911682676,111.29548174568967,19.402806443064204,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-480 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,480.0,442.5,2.372502,,,132.0,13.65,44.95,12.72,37.77,0.004641000000000001,-0.1146225,46.0,1.7408594247759834,13.66683043209875,8.113950349751605e-11,0.14071411446661589,114.12349189229008,23.225096494078468,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-485,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,485.0,448.8,2.372502,,,132.0,13.73,45.1,12.8,37.92,0.004805500000000001,-0.11500500000000001,45.9,1.720874970002738,13.747374562259363,5.540992755960888e-11,0.14275655571196702,112.81133267920086,19.433277704355728,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-485 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,485.0,447.2,2.372502,,,132.0,13.73,45.1,12.8,37.92,0.004668200000000001,-0.11500500000000001,46.0,1.746863884905168,13.746403903297587,8.188714100439297e-11,0.13825893013853677,115.72216051490575,23.256278174549788,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-490,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,490.0,453.5,2.372502,,,132.0,13.79,45.25,12.88,38.07,0.0048265,-0.1153875,45.9,1.7255201233762556,13.805915737228627,5.4865903945860073e-11,0.14072317676558632,121.92791284478068,19.287600027998216,-0.373,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-490 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,490.0,452.0,2.372502,,,132.0,13.79,45.25,12.88,38.07,0.0046886,-0.1153875,46.0,1.751566907251499,13.804989456203877,8.108844372322717e-11,0.13624346180267902,125.34126203501434,23.10686525885683,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-495,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,495.0,458.3,2.372502,,,132.0,13.86,45.4,12.96,38.22,0.004851,-0.11577000000000001,45.9,1.7308075669013192,13.875002543609735,5.4854106553138656e-11,0.13851295467694558,127.96427166118899,19.231633923273485,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-495 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,495.0,456.7,2.372502,,,132.0,13.86,45.4,12.96,38.22,0.0047124,-0.11577000000000001,46.0,1.7569289587955814,13.87410326085194,8.107280731987556e-11,0.13404731361671393,131.7351927546462,23.049447773468643,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-500,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,500.0,470.7,2.31,,,66.0,13.93,45.5,13.04,38.37,0.0061292,-0.12330500000000001,43.6,1.6850772358449533,13.945504611480876,2.5492008572983596e-11,0.14104915929520195,126.72454240069106,5.268304472251073,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-18X-505,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,505.0,475.5,2.31,,,66.0,13.99,45.7,13.12,38.52,0.0061556,-0.12384700000000001,43.6,1.6905291380348964,14.004421244412882,2.486895455049039e-11,0.14292064835787832,138.64683387619786,5.012847611479834,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-530,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,530.0,490.4,2.588905,,,144.0,13.76,49.2,12.83,41.35,0.004816000000000001,-0.12546000000000002,45.9,1.8767610935616574,13.777457869860438,5.51132067414209e-11,0.15697084653761784,123.72178739060597,19.359656634861604,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-530 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,530.0,488.8,2.588905,,,144.0,13.76,49.2,12.83,41.35,0.0046784,-0.12546000000000002,46.0,1.9050985191077214,13.776484742029949,8.145182183739543e-11,0.15207990615495467,126.94281335410204,23.180804478006618,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-535,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,535.0,495.2,2.588905,,,144.0,13.83,49.35,12.9,41.5,0.004840500000000001,-0.12584250000000002,45.9,1.882694244781359,13.847071562597044,5.557788230184501e-11,0.1545666383153412,125.21739650062852,19.390085763966347,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-535 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,535.0,493.5,2.588905,,,144.0,13.83,49.35,12.9,41.5,0.0047022,-0.12584250000000002,46.0,1.9111230363845504,13.846107391907937,8.213694916212062e-11,0.14968494553122652,128.5212919116009,23.211979124317455,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-540,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,540.0,500.0,2.588905,,,144.0,13.9,49.5,12.97,41.65,0.004865000000000001,-0.126225,45.9,1.8886283738791139,13.91669131662946,5.604453360153006e-11,0.1521882402347443,126.73754868440501,19.420450029998445,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-540 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,540.0,498.3,2.588905,,,144.0,13.9,49.5,12.97,41.65,0.004726000000000001,-0.126225,46.0,1.9171485937296937,13.91573610184514,8.28250146265986e-11,0.1473156860033431,130.12676685626934,23.243091009726793,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-545,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,545.0,504.7,2.588905,,,144.0,13.95,49.65,13.05,41.8,0.0048825,-0.1266075,45.9,1.89245382745456,13.964772370613668,5.4950079915303894e-11,0.1503801393483891,142.0085519522243,19.184077760503573,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-545 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,545.0,503.0,2.588905,,,144.0,13.95,49.65,13.05,41.8,0.004743,-0.1266075,46.0,1.9210106067427852,13.963878001254551,8.121648107052862e-11,0.14553214501071662,146.2871639781738,23.000679028855753,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-550,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,550.0,509.5,2.588905,,,144.0,14.0,49.8,13.12,41.95,0.004900000000000001,-0.12699,45.9,1.897027774568833,14.013423272861433,5.43925920074535e-11,0.14847478443077192,154.85396312143402,19.04340647166617,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-550 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,550.0,507.8,2.588905,,,144.0,14.0,49.8,13.12,41.95,0.004760000000000001,-0.12699,46.0,1.9256406263956032,14.012571738585487,8.039763318415257e-11,0.14364320747047823,159.96235642096485,22.856407876915082,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-555,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,555.0,514.3,2.588905,,,144.0,14.07,49.95,13.2,42.1,0.004924500000000001,-0.12737250000000003,45.9,1.9022461298015574,14.082578942521145,5.435907194825487e-11,0.146279617353239,163.61901832830833,18.984534187189634,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X-555 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,555.0,512.6,2.588905,,,144.0,14.07,49.95,13.2,42.1,0.004783800000000001,-0.12737250000000003,46.0,1.9309318843788013,14.081753631210727,8.03501050856801e-11,0.14146436405662502,169.3437196183177,22.796024406642736,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-560,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,560.0,526.7,2.58,,,72.0,14.07,50.5,13.25,42.3,0.006092310000000001,-0.118877,46.25,1.762707093354844,14.085887085808086,4.984348355345822e-12,0.19688098557742,174.36271849145876,6.080153676453512,-0.299,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-565,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,565.0,531.5,2.58,,,72.0,14.15,50.7,13.31,42.5,0.006126950000000001,-0.1193478,46.25,1.771265150687067,14.166854038604724,5.134920690986906e-12,0.19369119179464547,162.61564074893795,6.296377805725485,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-570,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,570.0,536.3,2.58,,,72.0,14.23,50.9,13.37,42.7,0.00616159,-0.1198186,46.25,1.779826605583655,14.247785176819123,5.2889370240066585e-12,0.19052892792665602,152.44305279126286,6.511352081509764,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-570,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,570.0,527.4,2.79851,,,156.0,13.68,53.19,12.76,44.68,0.004788000000000001,-0.13563450000000002,45.9,2.028041804656397,13.697293070845095,5.4170744395464454e-11,0.17286363631401294,136.74694242069717,19.247897344115874,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-570 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,570.0,525.6,2.79851,,,156.0,13.68,53.19,12.76,44.68,0.0046512,-0.13563450000000002,46.0,2.058653841762416,13.696328809918075,8.006357856566103e-11,0.1675535663426662,140.37353752654803,23.066221558508452,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-575,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,575.0,541.1,2.58,,,72.0,14.31,51.1,13.41,42.9,0.00619623,-0.1202894,46.25,1.7896262214002283,14.330016937450166,5.545204185024263e-12,0.18727802017879697,133.88404088298068,6.889866705808168,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-575,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,575.0,532.1,2.79851,,,156.0,13.75,53.34,12.83,44.83,0.004812500000000001,-0.13601700000000003,45.9,2.033945877399705,13.766924761114696,5.459877338375513e-11,0.17036871612692123,138.41080694281402,19.272943318093127,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-575 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,575.0,530.3,2.79851,,,156.0,13.75,53.34,12.83,44.83,0.004675,-0.13601700000000003,46.0,2.0646485534408736,13.765969008706053,8.06948795676509e-11,0.16507039074290167,142.13267275581367,23.091880985638944,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-580,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,580.0,546.0,2.58,,,72.0,14.39,51.3,13.47,43.1,0.0062308699999999995,-0.1207602,46.25,1.7981993230783633,14.410854976477653,5.709034451888615e-12,0.18416387497667286,127.07365870124151,7.102415599201297,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-580,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,580.0,536.9,2.79851,,,156.0,13.82,53.49,12.9,44.98,0.004837000000000001,-0.1363995,45.9,2.039851298876452,13.836561998654647,5.502872146575013e-11,0.16790060809271642,140.10304363334373,19.298002290995008,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-580 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,580.0,535.1,2.79851,,,156.0,13.82,53.49,12.9,44.98,0.004698800000000001,-0.1363995,46.0,2.070644645731291,13.835614753235342,8.132899450822647e-11,0.1626138945443812,143.92312268244888,23.117553440566937,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,585.0,550.8,2.58,,,72.0,14.47,51.5,13.53,43.3,0.006265510000000001,-0.121231,46.25,1.8067756760203795,14.491658334372218,5.876513143960484e-12,0.18107629849656545,120.97763356753049,7.313751711039498,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-585,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,585.0,541.7,2.79851,,,156.0,13.89,53.64,12.97,45.13,0.0048615,-0.136782,45.9,2.045758041691793,13.906204717897925,5.546057762806499e-11,0.16545888396844624,141.82437047995387,19.32307149782981,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-585 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,585.0,539.8,2.79851,,,156.0,13.89,53.64,12.97,45.13,0.0047226,-0.136782,46.0,2.0766421186724133,13.905265984582028,8.19659346199584e-11,0.16018364746421457,145.74565275387144,23.14323899644036,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-590,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,590.0,555.6,2.58,,,72.0,14.55,51.7,13.59,43.5,0.006300150000000001,-0.1217018,46.25,1.8153551713593148,14.572427317416317,6.047684330204988e-12,0.17801496039756742,115.48941087766894,7.523874420338827,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-590,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,590.0,546.4,2.79851,,,156.0,13.96,53.79,13.04,45.28,0.004886000000000001,-0.13716450000000002,45.9,2.051666103407636,13.97585285129508,5.58943482170011e-11,0.16304312140175653,143.5755592924181,19.34814932474497,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-590 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,590.0,544.6,2.79851,,,156.0,13.96,53.79,13.04,45.28,0.0047464000000000004,-0.13716450000000002,46.0,2.082640806321542,13.97492258995238,8.260554922532172e-11,0.1577792547481227,147.6016159583375,23.168917852396728,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-595,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,595.0,560.5,2.58,,,72.0,14.62,51.85,13.67,43.55,0.0063304599999999996,-0.12205490000000002,46.25,1.8181841364569615,14.642301072289426,5.857347532550576e-12,0.1841244253450782,120.70715999694816,7.193722313149874,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-595,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,595.0,551.2,2.79851,,,156.0,14.03,53.94,13.11,45.43,0.004910500000000001,-0.137547,45.9,2.057575437819243,14.045506333864182,5.633000868703672e-11,0.16065291263247133,145.3574004192242,19.373232157106564,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-595 {Clr},Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,595.0,549.4,2.79851,,,156.0,14.03,53.94,13.11,45.43,0.0047702000000000005,-0.137547,46.0,2.0886410489700613,14.04458462341931,8.324818108615823e-11,0.15540025013756056,149.49069791199958,23.19463077832594,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-600,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,600.0,565.3,2.58,,,72.0,14.7,52.0,13.73,43.7,0.006365099999999999,-0.122408,46.25,1.8248442313704931,14.723169055992193,6.0117896100286565e-12,0.1815700160385332,115.20017211455736,7.380306113893433,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT78-18X-600,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,0,600.0,565.1,2.72,,,78.0,14.1,54.09,13.17,45.58,0.0062039999999999994,-0.14658390000000002,43.6,2.004661406091518,14.117551357318083,2.62476763954944e-11,0.16828415305319558,135.19219756564956,5.423275251402704,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,645.0,607.1,3.07,,,66.0,18.35,44.8,17.11,37.7,0.006037150000000001,-0.10626559999999999,45.63,1.5597397582797858,18.380931639914532,5.964626602025733e-12,0.12380404393124277,73.44596710221357,4.729611201584365,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-650,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,650.0,611.9,3.07,,,66.0,18.39,45.0,17.16,37.9,0.00605031,-0.10674,45.63,1.5667854125924705,18.41971547247651,5.9914360699680385e-12,0.12202918838076476,75.52014448066754,4.74632909687752,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-655,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,655.0,616.7,3.07,,,66.0,18.43,45.2,17.2,38.1,0.00606347,-0.1072144,45.63,1.5742581160864066,18.45914718157518,6.061174970079553e-12,0.12022769228562041,76.0209478411952,4.826887238544515,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-660,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,660.0,621.5,3.07,,,66.0,18.47,45.4,17.24,38.3,0.0060766299999999995,-0.1076888,45.63,1.5817298066301893,18.498585588673485,6.131046393459368e-12,0.11843499591640694,76.52437740529321,4.906587351492028,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-665,Shanghai Aerospace Automobile Electromechanical Co Ltd,Mono-c-Si,1,665.0,626.3,3.07,,,66.0,18.51,45.6,17.28,38.5,0.00608979,-0.1081632,45.63,1.5892004985307928,18.53803061370586,6.201047193270117e-12,0.11665103457705918,77.03044514465084,4.9854352954067345,-0.3007,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shanghai ST Solar STP190-48,Shanghai ST Solar,Multi-c-Si,0,190.0,170.2,1.337,1.337,1.0,48.0,8.8,30.0,7.92,24.0,0.00528,-0.096,46.8,1.2728827104358975,8.84656849594909,4.818551687102884e-10,0.2857632394095087,54.0003839997792,17.03147641867546,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP190-54,Shanghai ST Solar,Multi-c-Si,0,190.0,169.7,1.494,1.494,1.0,54.0,8.12,32.5,7.31,26.0,0.004872,-0.10400000000000001,46.8,1.3787420474252141,8.162739717967536,4.431430376174297e-10,0.3355199983430893,63.74451427468193,16.998999217742146,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM195-72,Shanghai ST Solar,Mono-c-Si,0,195.0,174.3,1.2766400000000002,1.58,0.808,72.0,6.02,45.0,5.42,36.0,0.00301,-0.15300000000000002,47.1,1.9190659402381307,6.051274602267526,3.717944609477076e-10,0.6227783240679303,119.87764859839729,11.287066857187419,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP195-48,Shanghai ST Solar,Multi-c-Si,0,195.0,174.8,1.337,1.337,1.0,48.0,9.03,30.0,8.13,24.0,0.005417999999999999,-0.096,46.8,1.2726160378065836,9.077440164742416,4.922339144746692e-10,0.2785047907804555,53.012008631363024,16.98767815326023,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP195-54,Shanghai ST Solar,Multi-c-Si,0,195.0,174.3,1.494,1.494,1.0,54.0,8.33,32.5,7.5,26.0,0.004998,-0.10400000000000001,46.8,1.3786431195554785,8.373735850312269,4.539050626677675e-10,0.3270695777946603,62.29419890839091,16.983997813493016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM200-72,Shanghai ST Solar,Mono-c-Si,0,200.0,178.9,1.2766400000000002,1.58,0.808,72.0,6.18,45.0,5.56,36.0,0.0030900000000000003,-0.15300000000000002,47.1,1.9198760925564724,6.212568973330883,3.8513015748359207e-10,0.6065563196717532,115.09476474703806,11.370556068989448,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP200-48,Shanghai ST Solar,Multi-c-Si,0,200.0,179.4,1.337,1.337,1.0,48.0,9.26,30.0,8.33,24.0,0.005556,-0.096,46.8,1.2732300240753922,9.309463289148985,5.100156590450392e-10,0.27154183947330274,50.83522827640943,17.088515747542484,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP200-54,Shanghai ST Solar,Multi-c-Si,0,200.0,178.8,1.494,1.494,1.0,54.0,8.39,33.1,7.55,26.48,0.005034,-0.10592000000000001,46.8,1.404519588298264,8.43451396827621,4.601463156337954e-10,0.33069107263467545,62.328710202506024,17.047205105587306,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP205-54,Shanghai ST Solar,Multi-c-Si,0,205.0,183.4,1.494,1.494,1.0,54.0,8.6,33.1,7.74,26.48,0.00516,-0.10592000000000001,46.8,1.404413923903776,8.645510121043275,4.709039152064958e-10,0.32262448210669575,60.96601504881216,17.03147636124758,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM210-96,Shanghai ST Solar,Mono-c-Si,0,210.0,186.6,1.6874400000000003,1.58,1.068,96.0,5.05,57.88,4.54,46.3,0.002525,-0.19679200000000005,47.1,2.4703180907941515,5.077026145374799,3.172190127906676e-10,0.9556311866195321,178.56552491257895,11.444471388797238,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP210-54,Shanghai ST Solar,Multi-c-Si,0,210.0,188.0,1.494,1.494,1.0,54.0,8.81,33.1,7.93,26.48,0.005286000000000001,-0.10592000000000001,46.8,1.4043133492866007,8.85650626687916,4.816629690643038e-10,0.31494203078916544,59.661625324285396,17.016505253832005,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP210-60,Shanghai ST Solar,Multi-c-Si,0,210.0,187.6,1.625,1.625,1.0,60.0,8.1,36.0,7.29,28.8,0.00486,-0.1152,46.8,1.5274592522368933,8.14286418378002,4.4352577868662257e-10,0.37255059349641656,70.4005007246849,17.031476604894397,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP215-54,Shanghai ST Solar,Multi-c-Si,0,215.0,192.6,1.494,1.494,1.0,54.0,8.78,34.0,7.9,27.2,0.005267999999999999,-0.10880000000000001,46.8,1.442807887923644,8.826692934247381,4.822438394126431e-10,0.3245865130208347,61.034283087742395,17.061543563882964,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP215-60,Shanghai ST Solar,Multi-c-Si,0,215.0,192.2,1.625,1.625,1.0,60.0,8.29,36.0,7.47,28.8,0.004973999999999999,-0.1152,46.8,1.5264152779525957,8.332833064042198,4.473257715517739e-10,0.3640970242783393,70.46809742804876,16.888583528782977,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP220-54,Shanghai ST Solar,Multi-c-Si,0,220.0,197.2,1.494,1.494,1.0,54.0,8.99,34.0,8.09,27.2,0.005394,-0.10880000000000001,46.8,1.4427016968065431,9.037689093406453,4.930000275019278e-10,0.3170125251267141,59.760892485186936,17.04615505377218,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP220-60,Shanghai ST Solar,Multi-c-Si,0,220.0,196.8,1.625,1.625,1.0,60.0,8.3,36.8,7.47,29.44,0.00498,-0.11776,46.8,1.5614027911788249,8.343922558688114,4.5447703249866677e-10,0.371652881224793,70.23086096432777,17.031476601957646,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM225-96,Shanghai ST Solar,Mono-c-Si,0,225.0,200.3,1.6874400000000003,1.58,1.068,96.0,5.33,58.75,4.78,47.0,0.0026650000000000003,-0.19975,47.1,2.511164280065315,5.359833040398771,3.4557937060771904e-10,0.9174968624771515,163.92089281267988,11.738286374822199,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP225-54,Shanghai ST Solar,Multi-c-Si,0,225.0,201.8,1.494,1.494,1.0,54.0,9.19,34.0,8.27,27.2,0.005514,-0.10880000000000001,46.8,1.4426994918660276,9.23874746837759,5.039512661152819e-10,0.3101136141914563,58.46343185924046,17.045835541812224,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP225-60,Shanghai ST Solar,Multi-c-Si,0,225.0,201.4,1.625,1.625,1.0,60.0,8.49,36.8,7.64,29.44,0.0050940000000000004,-0.11776,46.8,1.5615188672758475,8.535043159507765,4.656218149868442e-10,0.3633261933367887,68.48186529405318,17.047014494977475,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP230-60,Shanghai ST Solar,Multi-c-Si,0,230.0,206.0,1.625,1.625,1.0,60.0,8.68,36.8,7.81,29.44,0.005208,-0.11776,46.8,1.5616194751276218,8.72616439447719,4.766927300580109e-10,0.35536716246659455,66.81745104401722,17.060391059283074,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM235-96,Shanghai ST Solar,Mono-c-Si,0,235.0,209.4,1.6874400000000003,1.58,1.068,96.0,5.55,58.8,5.0,47.04,0.002775,-0.19992000000000001,47.1,2.5066641762612623,5.578472119952587,3.401057835944281e-10,0.8827988572496944,172.08181268650534,11.214873865392589,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP235-60,Shanghai ST Solar,Multi-c-Si,0,235.0,210.6,1.625,1.625,1.0,60.0,8.7,37.5,7.83,30.0,0.00522,-0.12,46.8,1.5911033879729772,8.746039308493204,4.76379540945252e-10,0.36130984287872225,68.27634771072896,17.031476492973752,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM240-96,Shanghai ST Solar,Mono-c-Si,0,240.0,214.0,1.6874400000000003,1.58,1.068,96.0,5.56,60.0,5.0,48.0,0.00278,-0.20400000000000001,47.1,2.5604882548765735,5.5895529256732255,3.483849377680897e-10,0.8988359671220982,169.10435157485682,11.421060526947509,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP240-60,Shanghai ST Solar,Multi-c-Si,0,240.0,215.2,1.625,1.625,1.0,60.0,8.89,37.5,8.0,30.0,0.005334,-0.12,46.8,1.5912163673472133,8.93715990610995,4.875244276844546e-10,0.3535791000495474,66.65234645911298,17.046317025219246,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM245-96,Shanghai ST Solar,Mono-c-Si,0,245.0,218.6,1.6874400000000003,1.58,1.068,96.0,5.67,60.0,5.1,48.0,0.0028350000000000003,-0.20400000000000001,47.1,2.5601738801994354,5.700014338783047,3.543477993799621e-10,0.881440427505992,166.51266637943763,11.396763520149545,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP245-60,Shanghai ST Solar,Multi-c-Si,0,245.0,219.8,1.625,1.625,1.0,60.0,9.07,37.5,8.17,30.0,0.005442,-0.12,46.8,1.590329782724486,9.117191135530962,4.914896675265383e-10,0.3466284277371029,66.62098735039748,16.92982932293156,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP245-72,Shanghai ST Solar,Multi-c-Si,0,245.0,218.7,1.966,1.966,1.0,72.0,7.88,43.2,7.09,34.56,0.0047279999999999996,-0.13824000000000003,46.8,1.8332448361498708,7.921930249319809,4.3296340979216453e-10,0.459516509725964,86.35747206577534,17.06497260826004,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM250-96,Shanghai ST Solar,Mono-c-Si,0,250.0,223.2,1.6874400000000003,1.58,1.068,96.0,5.79,60.0,5.21,48.0,0.002895,-0.20400000000000001,47.1,2.5595859446348945,5.820413817169248,3.600779470411427e-10,0.8632490113502257,164.34017801527585,11.351323396246922,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP250-60,Shanghai ST Solar,Multi-c-Si,0,250.0,224.4,1.625,1.625,1.0,60.0,9.26,37.5,8.33,30.0,0.005556,-0.12,46.8,1.5915375289631026,9.309463289632367,5.100156479735728e-10,0.3394273004327442,63.544034944589974,17.088514556128594,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP250-72,Shanghai ST Solar,Multi-c-Si,0,250.0,223.3,1.966,1.966,1.0,72.0,8.04,43.2,7.23,34.56,0.004824,-0.13824000000000003,46.8,1.8338157738750052,8.083237407068136,4.4471137074149764e-10,0.45032264380360204,83.73754419705297,17.13009225206392,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM255-104,Shanghai ST Solar,Mono-c-Si,0,255.0,227.3,1.8316200000000002,1.715,1.068,104.0,5.56,63.7,5.0,50.96,0.00278,-0.21658000000000002,47.1,2.718385028380149,5.5895529257322965,3.483849308116177e-10,0.9542641864113858,179.5324531392789,11.421060165874552,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM255-96,Shanghai ST Solar,Mono-c-Si,0,255.0,227.8,1.6874400000000003,1.58,1.068,96.0,5.9,60.0,5.31,48.0,0.0029500000000000004,-0.20400000000000001,47.1,2.5593013655004846,5.930875192768519,3.6604905982577415e-10,0.8471907824454882,161.89132849901858,11.32932816545893,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP255-72,Shanghai ST Solar,Multi-c-Si,0,255.0,227.8,1.966,1.966,1.0,72.0,8.2,43.2,7.38,34.56,0.004919999999999999,-0.13824000000000003,46.8,1.8329511023768144,8.243393371252122,4.4900140375451643e-10,0.4416087524082218,83.45034964372238,17.031476537851052,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM260-104,Shanghai ST Solar,Mono-c-Si,0,260.0,231.9,1.8316200000000002,1.715,1.068,104.0,5.56,65.0,5.0,52.0,0.00278,-0.22100000000000003,47.1,2.7738622733602467,5.589552925763774,3.4838492902988716e-10,0.9737389660587742,183.1963805571551,11.421060127534803,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM260-96,Shanghai ST Solar,Mono-c-Si,0,260.0,232.4,1.6874400000000003,1.58,1.068,96.0,6.02,60.0,5.42,48.0,0.00301,-0.20400000000000001,47.1,2.5587545880169995,6.051274602230586,3.7179446472473275e-10,0.8303710980215656,159.83686483093578,11.287067115134894,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP260-72,Shanghai ST Solar,Multi-c-Si,0,260.0,232.4,1.966,1.966,1.0,72.0,8.36,43.2,7.52,34.56,0.005016,-0.13824000000000003,46.8,1.83350321725975,8.404700691812227,4.607248174860272e-10,0.433111788578798,81.00131423699555,17.09443068764483,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM265-104,Shanghai ST Solar,Mono-c-Si,0,265.0,236.4,1.8316200000000002,1.715,1.068,104.0,5.66,65.0,5.1,52.0,0.0028300000000000005,-0.22100000000000003,47.1,2.770689567559145,5.688933429738178,3.460916330257529e-10,0.9569537506582292,187.20071108884093,11.194700529317187,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP265-72,Shanghai ST Solar,Multi-c-Si,0,265.0,237.0,1.966,1.966,1.0,72.0,8.35,44.1,7.51,35.28,0.00501,-0.14112,46.8,1.8718456116946325,8.39476278724839,4.609359973904588e-10,0.44265206849915784,82.57182439235326,17.110579763740706,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM270-104,Shanghai ST Solar,Mono-c-Si,0,270.0,241.0,1.8316200000000002,1.715,1.068,104.0,5.77,65.0,5.19,52.0,0.002885,-0.22100000000000003,47.1,2.773505303273124,5.800537648033737,3.605518207746888e-10,0.9383466682304775,177.29789327761608,11.395593522360214,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP270-72,Shanghai ST Solar,Multi-c-Si,0,270.0,241.6,1.966,1.966,1.0,72.0,8.5,44.1,7.65,35.28,0.0051,-0.14112,46.8,1.8711375842571787,8.54498093358541,4.654282871049927e-10,0.4348980311120578,82.18223161113902,17.031476493088874,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM275-104,Shanghai ST Solar,Mono-c-Si,0,275.0,245.6,1.8316200000000002,1.715,1.068,104.0,5.88,65.0,5.29,52.0,0.00294,-0.22100000000000003,47.1,2.773183858483091,5.910999047255628,3.6651772437303824e-10,0.9208339774429174,174.66679313611976,11.372660925365249,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP275-72,Shanghai ST Solar,Multi-c-Si,0,275.0,246.2,1.966,1.966,1.0,72.0,8.66,44.1,7.79,35.28,0.005195999999999999,-0.14112,46.8,1.8716835633035067,8.706288157627055,4.771627654109678e-10,0.4268195437019727,79.85319948750006,17.092475303007973,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM280-104,Shanghai ST Solar,Mono-c-Si,0,280.0,250.2,1.8316200000000002,1.715,1.068,104.0,5.98,65.0,5.38,52.0,0.0029900000000000005,-0.22100000000000003,47.1,2.773173692724649,6.01152235598336,3.7272185909653694e-10,0.9054367002457682,171.7673595654273,11.371936115825381,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP280-72,Shanghai ST Solar,Multi-c-Si,0,280.0,250.8,1.966,1.966,1.0,72.0,8.82,44.1,7.94,35.28,0.005292,-0.14112,46.8,1.8708699597011635,8.866444031272321,4.8147218250161e-10,0.4191401271285888,79.59722827960573,17.001575464228704,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM285-104,Shanghai ST Solar,Mono-c-Si,0,285.0,254.8,1.8316200000000002,1.715,1.068,104.0,6.09,65.0,5.48,52.0,0.0030450000000000004,-0.22100000000000003,47.1,2.7728695763957765,6.121983742619756,3.7869053443872287e-10,0.8891200121934202,169.2966744505682,11.350238983668415,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP285-72,Shanghai ST Solar,Multi-c-Si,0,285.0,255.4,1.966,1.966,1.0,72.0,8.8,45.0,7.92,36.0,0.00528,-0.14400000000000002,46.8,1.9093240656510027,8.846568495948985,4.818551686976292e-10,0.42864485911284184,81.00057615653355,17.03147642076642,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP290-72,Shanghai ST Solar,Multi-c-Si,0,290.0,260.0,1.966,1.966,1.0,72.0,8.95,45.0,8.06,36.0,0.00537,-0.14400000000000002,46.8,1.9086517644640906,8.996786474323724,4.863836488538963e-10,0.421511910748595,80.6329584561564,16.95786430173422,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP295-72,Shanghai ST Solar,Multi-c-Si,0,295.0,264.6,1.966,1.966,1.0,72.0,9.1,45.0,8.19,36.0,0.00546,-0.14400000000000002,46.8,1.9093240649254912,9.148156058352887,4.982820451631973e-10,0.4145137099976811,78.33022745782854,17.03147644696393,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STP300-72,Shanghai ST Solar,Multi-c-Si,0,300.0,269.2,1.966,1.966,1.0,72.0,9.26,45.0,8.33,36.0,0.005556,-0.14400000000000002,46.8,1.909845052780113,9.309463285919016,5.100157692156325e-10,0.40731275337578793,76.25284629589096,17.088519164527945,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM325-130,Shanghai ST Solar,Mono-c-Si,0,325.0,289.9,2.268945,1.715,1.323,130.0,5.56,81.25,5.0,65.0,0.00278,-0.27625,47.1,3.4673278425716427,5.589552925728143,3.483849314061326e-10,1.2171737070720952,228.99547596067086,11.421060177079697,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM330-130,Shanghai ST Solar,Mono-c-Si,0,330.0,294.5,2.268945,1.715,1.323,130.0,5.64,81.25,5.08,65.0,0.00282,-0.27625,47.1,3.464141330807468,5.669057420903552,3.465297289291217e-10,1.200332559187626,232.98269124604096,11.23918733113053,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM335-130,Shanghai ST Solar,Mono-c-Si,0,335.0,299.1,2.268945,1.715,1.323,130.0,5.73,81.25,5.15,65.0,0.0028650000000000004,-0.27625,47.1,3.4684529798269055,5.760785166513261,3.615308795238006e-10,1.1809114510857108,219.8014128365882,11.48527314484526,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM340-130,Shanghai ST Solar,Mono-c-Si,0,340.0,303.7,2.268945,1.715,1.323,130.0,5.81,81.25,5.23,65.0,0.002905,-0.27625,47.1,3.4653368550743173,5.840289940372676,3.596142409282048e-10,1.1650582684119724,223.47317104476005,11.307425401362789,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM345-130,Shanghai ST Solar,Mono-c-Si,0,345.0,308.3,2.268945,1.715,1.323,130.0,5.9,81.25,5.31,65.0,0.0029500000000000004,-0.27625,47.1,3.465720596274102,5.930875192818945,3.660490527700713e-10,1.1472375190111508,219.22784053101182,11.329327986636478,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Shanghai ST Solar STM350-130,Shanghai ST Solar,Mono-c-Si,0,350.0,312.9,2.268945,1.715,1.323,130.0,5.98,81.25,5.38,65.0,0.0029900000000000005,-0.27625,47.1,3.4664671169127086,6.011522355994106,3.7272186098620923e-10,1.1317958761302824,214.70919953974663,11.371935724677646,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Sharp NU-SA445,Sharp,Mono-c-Si,0,445.0,414.4,2.14,,,72.0,11.54,48.9,10.89,40.9,0.00579308,-0.14547749999999998,43.3,1.9314795342163908,11.54617193680843,1.153713262590056e-10,0.1924450936509698,359.82488791309896,9.779397678694895,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +Sharp NU-SA450,Sharp,Mono-c-Si,0,450.0,419.2,2.14,,,72.0,11.6,49.1,10.96,41.1,0.0058232,-0.1460725,43.3,1.9297808402599783,11.600005342658678,1.0341114503491499e-10,0.19057500731270144,413794.32401400385,8.730017883339872,-0.3954,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM320P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,320.0,297.4,1.97,,,48.0,9.0,46.5,8.36,38.3,0.005121,-0.14359200000000003,42.41,1.8533670005754381,9.015835523588422,1.1113658499004044e-10,0.3093755928561137,175.8312813840525,7.520413123906186,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM325P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,325.0,302.2,1.97,,,48.0,9.08,46.8,8.44,38.5,0.00516652,-0.1445184,42.41,1.8633879482188729,9.095805325163079,1.0934084320501476e-10,0.3152452741672381,181.10523713435938,7.29953430719998,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM330P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,330.0,306.9,1.97,,,48.0,9.13,47.2,8.53,38.7,0.00519497,-0.1457536,42.41,1.8708222199404827,9.142910046522502,9.873004229983964e-11,0.33454240976271804,236.58879071813658,6.3519752685134705,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM335P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,335.0,311.7,1.97,,,48.0,9.16,47.6,8.61,38.9,0.00521204,-0.14698880000000003,42.41,1.8774064164215576,9.168732067608477,8.811331394762279e-11,0.3542266265268505,371.58622622897497,5.328561488133496,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM340P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,340.0,316.4,1.97,,,48.0,9.2,48.0,8.7,39.1,0.0052347999999999995,-0.148224,42.41,1.8840771460953087,9.20396999490504,7.888111537529909e-11,0.37307647648842374,864.5612847095398,4.331639361617153,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM345M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,345.0,323.1,1.97,,,48.0,9.6,47.2,8.94,38.6,0.0046272,-0.13367040000000002,42.2,1.7926791703987264,9.61911558314283,3.4368419919699263e-11,0.3498140360230905,175.67943130116603,6.266006558676117,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM345P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,345.0,321.2,1.97,,,48.0,9.27,48.2,8.78,39.3,0.00527463,-0.14884160000000002,42.41,1.8914122966394695,9.27271419112585,7.90703584480768e-11,0.3669482184959037,1253.2685853997452,4.282440393216566,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM350M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,350.0,327.9,1.97,,,48.0,9.67,47.5,9.02,38.8,0.004660940000000001,-0.13452,42.2,1.8014760575901483,9.68808544766072,3.3398507348118e-11,0.35540147493522983,190.02749412188112,5.95121749515396,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM350P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,350.0,325.9,1.97,,,48.0,9.32,48.5,8.86,39.5,0.00530308,-0.149768,42.41,1.8994564791972628,9.320004192575086,7.591071843123159e-11,0.3730831904953334,829434.1875467853,3.8824040657341587,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM355M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,355.0,332.7,1.97,,,48.0,9.71,47.8,9.1,39.0,0.0046802200000000006,-0.1353696,42.2,1.8075425617299739,9.724199587208416,3.1213241571946633e-11,0.362084728235098,247.60175813918033,5.318981252323016,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM355P-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Multi-c-Si,0,355.0,330.7,1.97,,,48.0,9.4,48.8,8.94,39.7,0.0053486,-0.1506944,42.41,1.9105915114692558,9.400004326251091,7.59364508935615e-11,0.3777847001174794,820919.9604420257,3.8136128426551728,-0.3932,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM360M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,360.0,337.5,1.97,,,48.0,9.79,48.0,9.18,39.2,0.00471878,-0.135936,42.2,1.8155173409698782,9.803705997369132,3.167710053492486e-11,0.35599212822771387,254.28014186738406,5.3729280150693075,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM365M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,365.0,342.3,1.97,,,48.0,9.87,48.2,9.26,39.4,0.00475734,-0.13650240000000002,42.2,1.8234947835610094,9.883223344114148,3.214494807484238e-11,0.3500042948142148,261.2457489493088,5.4267237641932695,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM370M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,370.0,347.1,1.97,,,48.0,9.95,48.4,9.34,39.6,0.0047959,-0.1370688,42.2,1.8314748109252632,9.962751417916195,3.261676976362203e-11,0.34411855460028007,268.5175632087277,5.48036437352073,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM375M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,375.0,351.9,1.97,,,48.0,10.02,48.6,9.42,39.8,0.00482964,-0.1376352,42.2,1.8385575795329208,10.031408044055997,3.267327770120196e-11,0.33871284379687167,297.5008450205929,5.4296071126489025,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM375M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,375.0,350.5,2.13,,,52.0,9.56,51.3,8.97,41.8,0.00459836,-0.1440504,43.05,1.924930958441417,9.573440104669412,2.505134706920289e-11,0.40492853475433294,288.02728357862344,4.481539714344692,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM380M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,380.0,356.7,1.97,,,48.0,10.07,48.8,9.52,39.9,0.0048537400000000005,-0.1382016,42.2,1.8395830664616426,10.076589240617617,3.009307382281202e-11,0.34638227500283425,529.3583588359071,4.665456093239067,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM380M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,380.0,355.2,2.13,,,52.0,9.63,51.5,9.05,42.0,0.0046320300000000005,-0.144612,43.05,1.9318433994435456,9.642012582268046,2.5073930420280415e-11,0.398828508227908,319.7246436322012,4.421506092033117,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM385M-72H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,385.0,361.5,1.97,,,48.0,10.15,49.0,9.625,40.0,0.0048923000000000005,-0.138768,42.2,1.8428939383060627,10.153811465236872,2.8648572144144383e-11,0.35276211936759655,939.4118665572688,4.170202811442047,-0.3654,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM385M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,385.0,360.0,2.13,,,52.0,9.69,51.8,9.12,42.2,0.00466089,-0.1454544,43.05,1.940622723873472,9.700810932937081,2.4432761617158322e-11,0.4043561869397989,362.43047032620734,4.144044663204998,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM390M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,390.0,364.8,2.13,,,52.0,9.75,52.1,9.2,42.4,0.0046897499999999995,-0.1462968,43.05,1.9484017764060875,9.758539300913668,2.351933377634544e-11,0.40978767554942686,467.8872370849179,3.7607836068119407,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM395M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,395.0,369.6,2.13,,,52.0,9.79,52.4,9.27,42.6,0.004708989999999999,-0.1471392,43.05,1.955323272236089,9.79525436040563,2.2361813543174438e-11,0.41594117160927835,774.987605985971,3.2889910686632025,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM400M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,400.0,374.4,2.13,,,52.0,9.83,52.7,9.35,42.8,0.00472823,-0.1479816,43.05,1.9613073487951664,9.830819801194568,2.10237093362099e-11,0.42194877457242075,5059.4671692112925,2.7215447815710156,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM405M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,405.0,379.2,2.13,,,52.0,9.9,52.9,9.42,43.0,0.0047619,-0.14854320000000001,43.05,1.9683681570711111,9.90000946576134,2.1083501439314426e-11,0.41612393284517596,435220.3711192411,2.6828046736337523,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM410M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,410.0,383.9,2.13,,,52.0,10.0,53.0,9.49,43.2,0.00481,-0.148824,43.05,1.9782789614210459,10.003277547591335,2.3071524078837093e-11,0.39815478505208673,1214.7948738033065,3.364798684097422,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM415M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,415.0,388.7,2.13,,,52.0,10.1,53.1,9.58,43.3,0.0048581,-0.1491048,43.05,1.9829280165032255,10.103814357317042,2.3577332658738905e-11,0.3927277331737256,1039.8997529989388,3.4653187759355175,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shenglong PV-tech (Cambodia) Co LTD GLSM420M-78H-V,Shenglong PV-tech (Cambodia) Co LTD,Mono-c-Si,0,420.0,393.5,2.13,,,52.0,10.2,53.1,9.65,43.5,0.0049061999999999995,-0.1491048,43.05,1.9900960297534263,10.206274143333633,2.6130044817427016e-11,0.3649162529310932,593.2516142261527,4.259016076758746,-0.36,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV310-60MH,Shinsung E&G Co Ltd,Mono-c-Si,0,310.0,286.7,1.6626506,,,60.0,9.92,40.2,9.4,33.0,0.00393824,-0.10689180000000002,45.5,1.5083187821285657,9.924687607617333,2.6229466163808863e-11,0.275481085827521,582.9780717185328,10.527167469039822,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV310-60MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,310.0,286.7,1.66,,,60.0,9.92,40.2,9.4,33.0,0.00393824,-0.10689180000000002,45.5,1.5083187821285657,9.924687607617333,2.6229466163808863e-11,0.275481085827521,582.9780717185328,10.527167469039822,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV315-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,315.0,291.1,1.68,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV315-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,315.0,291.1,1.68,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV315-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,315.0,291.1,1.68,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV315-60MH,Shinsung E&G Co Ltd,Mono-c-Si,0,315.0,291.5,1.6626506,,,60.0,10.01,40.4,9.49,33.2,0.003973969999999999,-0.10742360000000001,45.5,1.5162980210567456,10.014312294120787,2.670205506788251e-11,0.27002094831551277,626.7916071715464,10.604202267207045,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV315-60MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,315.0,291.5,1.66,,,60.0,10.01,40.4,9.49,33.2,0.003973969999999999,-0.10742360000000001,45.5,1.5162980210567456,10.014312294120787,2.670205506788251e-11,0.27002094831551277,626.7916071715464,10.604202267207045,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM320MI,Shinsung E&G Co Ltd,Mono-c-Si,1,320.0,295.8,1.72,,,60.0,10.13,40.18,9.7,32.99,0.0046598,-0.11049500000000001,46.38,1.4973149213862798,10.130002568296987,2.2461809944570618e-11,0.25352241336386566,999995.1390653998,5.2338026205473955,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-BM320MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,320.0,295.8,1.72,,,60.0,10.13,40.18,9.7,32.99,0.0046598,-0.11049500000000001,46.38,1.4973149213862798,10.130002568296987,2.2461809944570618e-11,0.25352241336386566,999995.1390653998,5.2338026205473955,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV320-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,295.9,1.68,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,295.9,1.68,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,295.9,1.68,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,297.1,1.68,,,60.0,10.17,40.2,9.61,33.3,0.0035798400000000004,-0.1073742,46.0,1.470586869614562,10.17808480595428,1.3493971541644573e-11,0.24329426452417346,306.043546658805,4.137005085250907,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,297.1,1.68,,,60.0,10.17,40.2,9.61,33.3,0.0035798400000000004,-0.1073742,46.0,1.470586869614562,10.17808480595428,1.3493971541644573e-11,0.24329426452417346,306.043546658805,4.137005085250907,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-60M,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,294.5,1.66,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-60M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,294.5,1.66,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-60M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,294.5,1.66,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-60MH,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,296.2,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00401764,-0.10795540000000002,45.5,1.5249576510772322,10.124734683161039,2.752744209195485e-11,0.2641028903557208,564.4984535624722,10.78115587885921,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV320-60MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,320.0,296.2,1.66,,,60.0,10.12,40.6,9.59,33.4,0.00401764,-0.10795540000000002,45.5,1.5249576510772322,10.124734683161039,2.752744209195485e-11,0.2641028903557208,564.4984535624722,10.78115587885921,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM325MI,Shinsung E&G Co Ltd,Mono-c-Si,1,325.0,300.5,1.72,,,60.0,10.15,40.3,9.82,33.1,0.004669,-0.110825,46.38,1.5087796950032855,10.150002099497822,2.5486869801675923e-11,0.20677899134004707,999707.4276057429,6.298496969232544,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-BM325MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,325.0,300.5,1.72,,,60.0,10.15,40.3,9.82,33.1,0.004669,-0.110825,46.38,1.5087796950032855,10.150002099497822,2.5486869801675923e-11,0.20677899134004707,999707.4276057429,6.298496969232544,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV325-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,300.6,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,300.6,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,300.6,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,301.9,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0036185600000000003,-0.10790839999999999,46.0,1.4789509114164092,10.288402165735683,1.3898622943443762e-11,0.23780505783233014,290.9530814429537,4.297942002643689,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,301.9,1.68,,,60.0,10.28,40.4,9.71,33.5,0.0036185600000000003,-0.10790839999999999,46.0,1.4789509114164092,10.288402165735683,1.3898622943443762e-11,0.23780505783233014,290.9530814429537,4.297942002643689,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-60M,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,299.2,1.66,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-60M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,299.2,1.66,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-60M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,299.2,1.66,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-60MH,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV325-60MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,325.0,301.0,1.66,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM330MI,Shinsung E&G Co Ltd,Mono-c-Si,1,330.0,305.3,1.72,,,60.0,10.25,40.39,9.93,33.24,0.0047150000000000004,-0.11107250000000002,46.38,1.5143405343691692,10.250001961936272,2.6752264608081257e-11,0.19134603681417198,999710.1868081596,6.631406101678401,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-BM330MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,330.0,305.3,1.72,,,60.0,10.25,40.39,9.93,33.24,0.0047150000000000004,-0.11107250000000002,46.38,1.5143405343691692,10.250001961936272,2.6752264608081257e-11,0.19134603681417198,999710.1868081596,6.631406101678401,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV330-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,305.4,1.68,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV330-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,305.4,1.68,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV330-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,305.4,1.68,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV330-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,306.6,1.68,,,60.0,10.35,40.6,9.8,33.7,0.0036432,-0.10844260000000001,46.0,1.4853031656544802,10.356523293773137,1.3784062863815299e-11,0.23350649383129052,370.486492842027,4.16027778531454,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV330-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,306.6,1.68,,,60.0,10.35,40.6,9.8,33.7,0.0036432,-0.10844260000000001,46.0,1.4853031656544802,10.356523293773137,1.3784062863815299e-11,0.23350649383129052,370.486492842027,4.16027778531454,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV330-60MH,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV330-60MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,330.0,305.7,1.66,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM335MI,Shinsung E&G Co Ltd,Mono-c-Si,1,335.0,310.0,1.72,,,60.0,10.34,40.46,10.03,33.4,0.0047564,-0.11126500000000002,46.38,1.5198404067173739,10.340001783263201,2.8383871554705873e-11,0.1724280731681357,999835.3596823497,7.067482938938364,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-BM335MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,335.0,310.0,1.72,,,60.0,10.34,40.46,10.03,33.4,0.0047564,-0.11126500000000002,46.38,1.5198404067173739,10.340001783263201,2.8383871554705873e-11,0.1724280731681357,999835.3596823497,7.067482938938364,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV335-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,310.1,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV335-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,310.1,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV335-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,310.1,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV335-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,311.4,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0036678400000000003,-0.1089768,46.0,1.4916704712639977,10.424707889486557,1.3675037155016914e-11,0.22928073147299358,507.46842156262517,4.026101173018075,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV335-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,311.4,1.68,,,60.0,10.42,40.8,9.89,33.9,0.0036678400000000003,-0.1089768,46.0,1.4916704712639977,10.424707889486557,1.3675037155016914e-11,0.22928073147299358,507.46842156262517,4.026101173018075,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV335-60MH,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,310.5,1.6626506,,,60.0,10.41,41.2,9.86,34.0,0.00413277,-0.10955080000000002,45.5,1.550330407922102,10.415238841369867,2.970316332019816e-11,0.24806821503615692,492.93154694445747,11.213345460746005,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV335-60MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,335.0,310.5,1.66,,,60.0,10.41,41.2,9.86,34.0,0.00413277,-0.10955080000000002,45.5,1.550330407922102,10.415238841369867,2.970316332019816e-11,0.24806821503615692,492.93154694445747,11.213345460746005,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV340-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,340.0,314.9,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV340-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,340.0,314.9,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV340-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,340.0,314.9,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV340-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,340.0,316.2,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0037030400000000003,-0.10951100000000001,46.0,1.5000754629857609,10.525095002328262,1.4074691801651124e-11,0.22429505419933127,463.11735364585354,4.1911968749579716,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV340-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,340.0,316.2,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0037030400000000003,-0.10951100000000001,46.0,1.5000754629857609,10.525095002328262,1.4074691801651124e-11,0.22429505419933127,463.11735364585354,4.1911968749579716,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV345-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,345.0,321.0,1.68,,,60.0,10.69,41.2,10.06,34.3,0.00376288,-0.11004520000000001,46.0,1.5139648725580341,10.701083665498308,1.595095835029606e-11,0.21738028389039898,209.65945312218443,5.152786144849423,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV345-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,345.0,321.0,1.68,,,60.0,10.69,41.2,10.06,34.3,0.00376288,-0.11004520000000001,46.0,1.5139648725580341,10.701083665498308,1.595095835029606e-11,0.21738028389039898,209.65945312218443,5.152786144849423,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV350-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV350-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV350-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM355MB,Shinsung E&G Co Ltd,Mono-c-Si,0,355.0,330.2,1.82169,,,60.0,11.24,39.95,10.69,33.21,0.0057773600000000005,-0.11305849999999999,44.6,1.5195803169292241,11.241952211939779,4.283415482995063e-11,0.1941454428969692,1117.8063629660603,6.757740184784243,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM355MG,Shinsung E&G Co Ltd,Mono-c-Si,0,355.0,331.7,1.82169,,,60.0,11.24,39.95,10.69,33.21,0.0054514,-0.10986250000000002,43.8,1.5005420976828125,11.24240216739928,3.0666166177859315e-11,0.1980421656769329,926.6606647506314,6.99538992827871,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV355-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV355-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV355-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM360MB,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,335.0,1.82169,,,60.0,11.26,40.26,10.72,33.58,0.00578764,-0.11393579999999999,44.6,1.5332621631787304,11.261298679475525,4.4362771470927344e-11,0.18330862393734962,1589.3492927778195,7.042227322668435,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM360MG,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,336.5,1.82169,,,60.0,11.26,40.26,10.72,33.58,0.005461100000000001,-0.11071500000000001,43.8,1.5140259940379595,11.261710821276065,3.175884758256642e-11,0.1872435461695822,1232.368616027959,7.280282582342877,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV360-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV360-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV360-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV360-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,333.6,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV360-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,360.0,333.6,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM365MB,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,339.8,1.82169,,,60.0,11.28,40.59,10.76,33.92,0.00579792,-0.1148697,44.6,1.5458824079276716,11.28001986127196,4.457486314473677e-11,0.17773615487322847,100943.9767667315,7.0605677744186055,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM365MG,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,341.3,1.82169,,,60.0,11.28,40.59,10.76,33.92,0.0054708,-0.11162250000000001,43.8,1.526486028490102,11.280390672908407,3.190996608514393e-11,0.18169288303712666,5246.066817482161,7.298322100182556,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV365-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV365-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV365-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV365-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,338.3,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV365-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,365.0,338.3,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM370MB,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,344.6,1.82169,,,60.0,11.3,40.91,10.8,34.26,0.0058082,-0.11577529999999998,44.6,1.5607414676279112,11.300003158552784,4.6708106350645356e-11,0.1708255580956592,611165.5316364001,7.450265692742096,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM370MG,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,346.1,1.82169,,,60.0,11.3,40.91,10.8,34.26,0.0054805,-0.1125025,43.8,1.540408484326284,11.300003234567873,3.304689483818666e-11,0.17494745786439816,611197.2432118843,7.5847958193540475,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV370-120M,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV370-120M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV370-120M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV370-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,343.1,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV370-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,370.0,343.1,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM375MB,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,349.3,1.82169,,,60.0,11.32,41.24,10.84,34.59,0.005818480000000001,-0.1167092,44.6,1.5756627726273493,11.320003070403786,4.864132008347475e-11,0.16594399106358765,611826.4529514958,7.787511573150187,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-BM375MG,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,350.9,1.82169,,,60.0,11.32,41.24,10.84,34.59,0.005490200000000001,-0.11341000000000002,43.8,1.555113938604419,11.320003146988393,3.441970771463591e-11,0.17009405183678275,611859.977502454,7.924093549005215,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,347.9,1.83,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,347.9,1.83,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,346.9,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0035200000000000006,-0.123802,44.3,1.8403704061538573,10.00428728261265,5.2114750949449136e-11,0.27218043799176433,634.855393948642,19.93169112516487,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV375-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,375.0,346.9,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0035200000000000006,-0.123802,44.3,1.8403704061538573,10.00428728261265,5.2114750949449136e-11,0.27218043799176433,634.855393948642,19.93169112516487,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-120MH,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,352.7,1.83,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-120MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,352.7,1.83,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,380.0,351.8,2.019952,,,72.0,9.94,48.7,9.47,40.2,0.00365792,-0.12686350000000002,44.1,1.8703538668471484,9.94000293109458,4.8897683363662693e-11,0.2948571030371771,999999.7951051213,18.63565893658903,-0.3943,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV380-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035411200000000005,-0.12457900000000001,44.3,1.8528489333641933,10.06405444318326,5.3127904276577706e-11,0.266048689514278,660.127620280329,20.058810123472938,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035411200000000005,-0.12457900000000001,44.3,1.8528489333641933,10.06405444318326,5.3127904276577706e-11,0.266048689514278,660.127620280329,20.058810123472938,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-72M,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,349.5,1.97,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-72M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,349.5,1.97,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV380-72M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,380.0,349.5,1.97,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM385MI,Shinsung E&G Co Ltd,Mono-c-Si,1,385.0,356.3,1.98,,,72.0,10.05,48.1,9.74,39.53,0.004623,-0.13227500000000003,46.38,1.802633558787001,10.050002463759931,2.5930156900475055e-11,0.23602142129066303,962789.2459833642,6.532194155024599,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-DM385MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,385.0,356.3,1.98,,,72.0,10.05,48.1,9.74,39.53,0.004623,-0.13227500000000003,46.38,1.802633558787001,10.050002463759931,2.5930156900475055e-11,0.23602142129066303,962789.2459833642,6.532194155024599,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV385-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,385.0,356.5,2.019952,,,72.0,10.02,48.9,9.54,40.4,0.0036873599999999998,-0.1273845,44.1,1.8788252475668925,10.020272683365336,4.981287156802317e-11,0.2911013858907928,10696.794310584786,18.73804008578913,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00356224,-0.125356,44.3,1.865325586339818,10.123829146069554,5.4147856091863336e-11,0.2599954544828044,687.1386003150868,20.184106080070023,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00356224,-0.125356,44.3,1.865325586339818,10.123829146069554,5.4147856091863336e-11,0.2599954544828044,687.1386003150868,20.184106080070023,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-72M,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,354.2,1.97,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-72M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,354.2,1.97,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-72M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,354.2,1.97,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-72MH,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,355.9,1.97,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV385-72MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,385.0,355.9,1.97,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM390MI,Shinsung E&G Co Ltd,Mono-c-Si,1,390.0,361.0,1.98,,,72.0,10.14,48.18,9.83,39.68,0.0046644,-0.132495,46.38,1.8075171980119689,10.140002353958378,2.6900809186136108e-11,0.2233716431035707,962230.8964170993,6.772326157642555,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-DM390MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,390.0,361.0,1.98,,,72.0,10.14,48.18,9.83,39.68,0.0046644,-0.132495,46.38,1.8075171980119689,10.140002353958378,2.6900809186136108e-11,0.2233716431035707,962230.8964170993,6.772326157642555,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV390-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,390.0,361.3,2.019952,,,72.0,10.11,49.1,9.61,40.6,0.00372048,-0.1279055,44.1,1.8888196044867658,10.111535791483307,5.178179646456235e-11,0.2853672560425699,1878.5514444670425,19.03188159064435,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.003597440000000001,-0.125615,44.3,1.8593275438544012,10.220004579511636,4.7974062814489926e-11,0.2581122665961081,576042.6087871741,18.89679258881582,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.003597440000000001,-0.125615,44.3,1.8593275438544012,10.220004579511636,4.7974062814489926e-11,0.2581122665961081,576042.6087871741,18.89679258881582,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-72M,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,359.0,1.97,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-72M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,359.0,1.97,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-72M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,359.0,1.97,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-72MH,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,360.7,1.97,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV390-72MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,390.0,360.7,1.97,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM395MI,Shinsung E&G Co Ltd,Mono-c-Si,1,395.0,365.8,1.98,,,72.0,10.23,48.26,9.92,39.82,0.0047058000000000004,-0.132715,46.38,1.8122007840643877,10.230002255887863,2.781951654320625e-11,0.2120355955343556,961565.6709569648,6.986228725023647,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-DM395MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,395.0,365.8,1.98,,,72.0,10.23,48.26,9.92,39.82,0.0047058000000000004,-0.132715,46.38,1.8122007840643877,10.230002255887863,2.781951654320625e-11,0.2120355955343556,961565.6709569648,6.986228725023647,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV395-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,395.0,366.1,2.019952,,,72.0,10.19,49.3,9.69,40.8,0.0037499199999999995,-0.1284265,44.1,1.8969643961230733,10.191278177798583,5.2535802677672267e-11,0.28018836136610215,2233.7422988053127,19.093278838242796,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-72M,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,363.7,1.97,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-72M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,363.7,1.97,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-72M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,363.7,1.97,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-72MH,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.5,1.97,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV395-72MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,395.0,365.5,1.97,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM400MI,Shinsung E&G Co Ltd,Mono-c-Si,1,400.0,370.5,1.98,,,72.0,10.32,48.35,10.0,40.0,0.0047472,-0.1329625,46.38,1.8170768078232598,10.320002103549692,2.8686562924801072e-11,0.20381322927048903,999935.9701402877,7.1761488525547685,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-DM400MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,400.0,370.5,1.98,,,72.0,10.32,48.35,10.0,40.0,0.0047472,-0.1329625,46.38,1.8170768078232598,10.320002103549692,2.8686562924801072e-11,0.20381322927048903,999935.9701402877,7.1761488525547685,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV400-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,400.0,370.8,2.019952,,,72.0,10.27,49.5,9.76,41.0,0.00377936,-0.1289475,44.1,1.9060547876410128,10.271775061398586,5.392072254432332e-11,0.2749902088040534,1591.0152241884116,19.271336823762127,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV400-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036572800000000006,-0.126651,44.3,1.888111286326416,10.39496441517563,5.822153708655742e-11,0.24570320177805335,514.2310217656832,20.640799378756142,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV400-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036572800000000006,-0.126651,44.3,1.888111286326416,10.39496441517563,5.822153708655742e-11,0.24570320177805335,514.2310217656832,20.640799378756142,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV400-72MH,Shinsung E&G Co Ltd,Mono-c-Si,0,400.0,370.2,1.97,,,72.0,10.35,49.3,9.81,40.8,0.00475065,-0.1327156,46.6,1.8451951318838913,10.354863231731121,2.560095628839045e-11,0.28769900702457224,612.2851941076362,8.500356580606194,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV400-72MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,400.0,370.2,1.97,,,72.0,10.35,49.3,9.81,40.8,0.00475065,-0.1327156,46.6,1.8451951318838913,10.354863231731121,2.560095628839045e-11,0.28769900702457224,612.2851941076362,8.500356580606194,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM405MI,Shinsung E&G Co Ltd,Mono-c-Si,1,405.0,375.3,1.98,,,72.0,10.42,48.45,10.08,40.18,0.0047932,-0.1332375,46.38,1.8213988955334646,10.420002104875977,2.920413510346616e-11,0.20198300112671758,999928.8740275401,7.24756968963717,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SS-DM405MJ,Shinsung E&G Co Ltd,Mono-c-Si,1,405.0,375.3,1.98,,,72.0,10.42,48.45,10.08,40.18,0.0047932,-0.1332375,46.38,1.8213988955334646,10.420002104875977,2.920413510346616e-11,0.20198300112671758,999928.8740275401,7.24756968963717,-0.358,N,2025.7.3,6/23/2025,2.0,first_pass +Shinsung E&G Co Ltd SSV405-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,405.0,375.6,2.019952,,,72.0,10.36,49.7,9.84,41.2,0.00381248,-0.12946850000000001,44.1,1.9150965232042887,10.362221161363351,5.534973370073587e-11,0.26961177323810237,1257.530518679656,19.441965047514433,-0.3943,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shinsung E&G Co Ltd SSV405-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036889600000000002,-0.127169,44.3,1.897121790906059,10.485311894009968,5.972624676154759e-11,0.24060985034767018,474.70663113210384,20.807843969991662,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV405-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036889600000000002,-0.127169,44.3,1.897121790906059,10.485311894009968,5.972624676154759e-11,0.24060985034767018,474.70663113210384,20.807843969991662,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV405-72MH,Shinsung E&G Co Ltd,Mono-c-Si,0,405.0,375.0,1.97,,,72.0,10.43,49.5,9.88,41.0,0.004787370000000001,-0.13325399999999998,46.6,1.8540001772225838,10.43533561437403,2.6273687373196756e-11,0.28258372101983764,552.3915448649208,8.663511168231926,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV405-72MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,405.0,375.0,1.97,,,72.0,10.43,49.5,9.88,41.0,0.004787370000000001,-0.13325399999999998,46.6,1.8540001772225838,10.43533561437403,2.6273687373196756e-11,0.28258372101983764,552.3915448649208,8.663511168231926,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV410-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,410.0,380.4,2.019952,,,72.0,10.44,49.9,9.91,41.4,0.0038419199999999995,-0.1299895,44.1,1.9241840112185633,10.442686735556379,5.6780524709429845e-11,0.26456859499995916,1028.049192306514,19.616857948034195,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV420-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,420.0,391.6,2.19,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV420-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,420.0,391.6,2.19,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV420-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,420.0,391.6,2.19,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV425-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV425-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV425-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM430MB,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,400.1,2.173572,,,72.0,10.85,49.17,10.36,41.51,0.0055769,-0.1391511,44.6,1.881818863743937,10.85000321552008,4.872551802782126e-11,0.1772599058719866,598137.0895725198,8.172491053553383,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM430MD,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,400.1,2.173572,,,72.0,10.85,49.17,10.36,41.51,0.0055769,-0.1391511,44.6,1.881818863743937,10.85000321552008,4.872551802782126e-11,0.1772599058719866,598137.0895725198,8.172491053553383,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM430ME,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,402.0,2.173572,,,72.0,10.85,49.17,10.36,41.51,0.0052622500000000004,-0.13521750000000002,43.8,1.857860840980441,10.850210415245918,3.477162304292144e-11,0.18236791424594007,9403.750581239066,8.38562720001263,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM430MG,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,402.0,2.173572,,,72.0,10.85,49.17,10.36,41.51,0.0052622500000000004,-0.13521750000000002,43.8,1.857860840980441,10.850210415245918,3.477162304292144e-11,0.18236791424594007,9403.750581239066,8.38562720001263,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,430.0,399.5,2.19,,,72.0,11.2,48.6,10.65,40.4,0.005667199999999999,-0.13617720000000003,45.73,1.8180253111844236,11.20268608795852,2.7401280751950135e-11,0.2433949386125851,1014.867514091067,4.048255497691683,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,430.0,400.7,2.2,,,72.0,11.2,48.6,10.65,40.4,0.0058464,-0.12864420000000001,46.18,1.7736195709576112,11.203608812022006,1.4014831304133904e-11,0.25259689697451,783.9381137137947,4.3315520029135905,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV430-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM435MB,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,404.9,2.173572,,,72.0,10.92,49.38,10.42,41.75,0.005612880000000001,-0.1397454,44.6,1.8917093824296807,10.920324707305111,5.027357965329151e-11,0.16987521984893936,5712.955711843459,8.392575249517774,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM435MD,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,404.9,2.173572,,,72.0,10.92,49.38,10.42,41.75,0.005612880000000001,-0.1397454,44.6,1.8917093824296807,10.920324707305111,5.027357965329151e-11,0.16987521984893936,5712.955711843459,8.392575249517774,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM435ME,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,406.7,2.173572,,,72.0,10.92,49.38,10.42,41.75,0.0052962,-0.13579500000000003,43.8,1.8678222820793717,10.920602161921494,3.59828087847035e-11,0.1749486777957613,3172.6346266597707,8.63301155996102,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM435MG,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,406.7,2.173572,,,72.0,10.92,49.38,10.42,41.75,0.0052962,-0.13579500000000003,43.8,1.8678222820793717,10.920602161921494,3.59828087847035e-11,0.1749486777957613,3172.6346266597707,8.63301155996102,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,435.0,404.3,2.19,,,72.0,11.28,48.8,10.72,40.6,0.00570768,-0.1367376,45.73,1.8202240652369313,11.280009835601975,2.5639941656017372e-11,0.2402188702954857,274907.3634086092,3.4159122983871115,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,435.0,405.5,2.2,,,72.0,11.28,48.8,10.72,40.6,0.00588816,-0.1291736,46.18,1.7821323295289642,11.284085713182504,1.4370187416705828e-11,0.24818858603407964,685.2089620092718,4.486572628156489,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV435-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM440MB,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,409.7,2.173572,,,72.0,11.0,49.57,10.48,41.99,0.005654,-0.1402831,44.6,1.9022860463391562,11.001121013055851,5.288016095332901e-11,0.1602825134933277,1572.7807601927511,8.779257649411424,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM440MD,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,409.7,2.173572,,,72.0,11.0,49.57,10.48,41.99,0.005654,-0.1402831,44.6,1.9022860463391562,11.001121013055851,5.288016095332901e-11,0.1602825134933277,1572.7807601927511,8.779257649411424,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM440ME,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,411.5,2.173572,,,72.0,11.0,49.57,10.48,41.99,0.005335,-0.1363175,43.8,1.8782547753931707,11.001410582505075,3.7864864412515284e-11,0.1653658795142822,1289.555731828956,9.024865430918119,-0.3581,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shinsung E&G Co Ltd SS-DM440MG,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,411.5,2.173572,,,72.0,11.0,49.57,10.48,41.99,0.005335,-0.1363175,43.8,1.8782547753931707,11.001410582505075,3.7864864412515284e-11,0.1653658795142822,1289.555731828956,9.024865430918119,-0.3581,N,2025.7.3,6/23/2025,4.0,bootstrapping +Shinsung E&G Co Ltd SSV440-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,440.0,409.1,2.19,,,72.0,11.36,49.0,10.79,40.8,0.0057481599999999996,-0.137298,45.73,1.835545722299805,11.363600735843491,2.880463272260888e-11,0.23464058188946083,740.2693984723514,4.355292070002174,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV440-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,440.0,410.2,2.2,,,72.0,11.36,49.0,10.79,40.8,0.00592992,-0.12970299999999998,46.18,1.7906468120454178,11.364546684070904,1.4731730898878516e-11,0.24383738356960658,609.2336013054614,4.640564388186096,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV440-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV440-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV440-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV440-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV440-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM445MB,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,414.5,2.173572,,,72.0,11.07,49.75,10.54,42.22,0.005689980000000001,-0.1407925,44.6,1.9062132743709461,11.070005057759815,5.1232974842070644e-11,0.15231083730402212,333369.9730426703,8.435872753617394,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM445MD,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,414.5,2.173572,,,72.0,11.07,49.75,10.54,42.22,0.005689980000000001,-0.1407925,44.6,1.9062132743709461,11.070005057759815,5.1232974842070644e-11,0.15231083730402212,333369.9730426703,8.435872753617394,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM445ME,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,416.3,2.173572,,,72.0,11.07,49.75,10.54,42.22,0.005368950000000001,-0.1368125,43.8,1.8874356283911302,11.071706003210728,3.934859242567407e-11,0.15634937125046608,1014.5277504627246,9.311492878789796,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM445MG,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,416.3,2.173572,,,72.0,11.07,49.75,10.54,42.22,0.005368950000000001,-0.1368125,43.8,1.8874356283911302,11.071706003210728,3.934859242567407e-11,0.15634937125046608,1014.5277504627246,9.311492878789796,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,445.0,413.9,2.19,,,72.0,11.44,49.2,10.86,41.0,0.00578864,-0.13785840000000002,45.73,1.835639702713268,11.440008104073144,2.619266198324467e-11,0.2319581994411014,327443.93842825794,3.4766142069454764,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,445.0,415.0,2.2,,,72.0,11.44,49.2,10.86,41.0,0.00597168,-0.1302324,46.18,1.7991560127923258,11.444992006744556,1.5097907470607593e-11,0.23954361297106808,548.9533773374214,4.792628652127338,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144M,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144M-BB,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144M-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV445-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM450MB,Shinsung E&G Co Ltd,Mono-c-Si,0,450.0,419.3,2.173572,,,72.0,11.14,49.93,10.6,42.45,0.00572596,-0.14130189999999998,44.6,1.914164899091619,11.140005009163511,5.2303730387758694e-11,0.1436540104328657,319479.99230699136,8.561887823422488,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM450MD,Shinsung E&G Co Ltd,Mono-c-Si,0,450.0,419.3,2.173572,,,72.0,11.14,49.93,10.6,42.45,0.00572596,-0.14130189999999998,44.6,1.914164899091619,11.140005009163511,5.2303730387758694e-11,0.1436540104328657,319479.99230699136,8.561887823422488,-0.3656,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM450ME,Shinsung E&G Co Ltd,Mono-c-Si,0,450.0,421.1,2.173572,,,72.0,11.14,49.93,10.6,42.45,0.0054029,-0.13730750000000003,43.8,1.889065414901733,11.140005162630102,3.6984191587170197e-11,0.14891398145571033,321332.0411975849,8.693771558054447,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SS-DM450MG,Shinsung E&G Co Ltd,Mono-c-Si,0,450.0,421.1,2.173572,,,72.0,11.14,49.93,10.6,42.45,0.0054029,-0.13730750000000003,43.8,1.889065414901733,11.140005162630102,3.6984191587170197e-11,0.14891398145571033,321332.0411975849,8.693771558054447,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV450-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,450.0,418.6,2.19,,,72.0,11.52,49.4,10.93,41.2,0.00582912,-0.1384188,45.73,1.84335367378993,11.520008773206037,2.647262677155741e-11,0.22790756309998217,299265.75425745465,3.5073354506376067,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV450-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,450.0,419.8,2.2,,,72.0,11.52,49.4,10.93,41.2,0.00601344,-0.13076179999999998,46.18,1.7969841838686,11.520009160393652,1.325783494709557e-11,0.2372942764143096,298419.95043445873,3.6040100690140706,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV450-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV450-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV455-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,455.0,423.4,2.19,,,72.0,11.6,49.6,11.0,41.4,0.005869599999999999,-0.13897920000000002,45.73,1.8618220979285522,11.604855100128345,3.099365329859322e-11,0.22192959770729734,530.2431081577184,4.806119732765015,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV455-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,455.0,424.6,2.2,,,72.0,11.6,49.6,11.0,41.4,0.0060552,-0.1312912,46.18,1.8045042992712832,11.600007575524174,1.339982873294223e-11,0.23328450508339485,357218.4381162309,3.6355084633908232,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV455-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV455-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV460-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,460.0,428.2,2.19,,,72.0,11.67,49.8,11.06,41.6,0.0059050199999999995,-0.1395396,45.73,1.8587443695151087,11.670006538318638,2.6997709953783426e-11,0.22016074964191015,392961.5160338726,3.5635598368031367,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV460-144BMH-DG,Shinsung E&G Co Ltd,Mono-c-Si,1,460.0,429.4,2.2,,,72.0,11.67,49.8,11.06,41.6,0.00609174,-0.13182059999999998,46.18,1.8119950337359891,11.670006808861357,1.3524640770911125e-11,0.22953156131228208,393406.6492862048,3.662985431955832,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV460-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV460-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV465-144BMH,Shinsung E&G Co Ltd,Mono-c-Si,1,465.0,433.0,2.19,,,72.0,11.75,50.0,11.13,41.8,0.0059455,-0.1401,45.73,1.866461336782094,11.75000615562789,2.7281357218389692e-11,0.21625928509074893,412805.86231370433,3.5939336907421433,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV465-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV465-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV470-144MH,Shinsung E&G Co Ltd,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Shinsung E&G Co Ltd SSV470-144MH-BW,Shinsung E&G Co Ltd,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA240P,Silfab Solar Inc,Multi-c-Si,0,240.0,215.8,1.6335,1.65,0.99,60.0,8.53,37.1,8.01,30.1,0.0043503,-0.11315499999999999,48.2,1.4778203554389788,8.538693128215554,1.0535050745141402e-10,0.3231766388191872,317.11218828531617,8.893835135270901,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA245P,Silfab Solar Inc,Multi-c-Si,0,245.0,220.4,1.6335,1.65,0.99,60.0,8.64,37.3,8.13,30.3,0.0044063999999999996,-0.11376499999999999,48.2,1.4852567104503311,8.647098433425853,1.060003178718739e-10,0.3154245844211609,383.92536213886694,8.827847052526534,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA245P,Silfab Solar Inc,Multi-c-Si,0,245.0,220.4,1.6335,1.65,0.99,60.0,8.64,37.3,8.13,30.3,0.0044063999999999996,-0.11376499999999999,48.2,1.4852567104503311,8.647098433425853,1.060003178718739e-10,0.3154245844211609,383.92536213886694,8.827847052526534,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA250P,Silfab Solar Inc,Multi-c-Si,0,250.0,225.0,1.6335,1.65,0.99,60.0,8.76,37.5,8.24,30.5,0.0044675999999999995,-0.114375,48.2,1.494498374097324,8.767438001107145,1.0974407206267692e-10,0.3074314954178503,362.07311472453836,9.013309166364916,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA250P,Silfab Solar Inc,Multi-c-Si,0,250.0,225.0,1.6335,1.65,0.99,60.0,8.76,37.5,8.24,30.5,0.0044675999999999995,-0.114375,48.2,1.494498374097324,8.767438001107145,1.0974407206267692e-10,0.3074314954178503,362.07311472453836,9.013309166364916,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA255P,Silfab Solar Inc,Multi-c-Si,0,255.0,229.6,1.6335,1.65,0.99,60.0,8.89,38.1,8.34,30.6,0.0045339,-0.116205,48.2,1.5099498018031998,8.900407586664917,9.659780140468794e-11,0.3621342213021225,309.3294875284176,7.7752470885520415,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA255P,Silfab Solar Inc,Multi-c-Si,0,255.0,229.6,1.6335,1.65,0.99,60.0,8.89,38.1,8.34,30.6,0.0045339,-0.116205,48.2,1.5099498018031998,8.900407586664917,9.659780140468794e-11,0.3621342213021225,309.3294875284176,7.7752470885520415,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA260M,Silfab Solar Inc,Mono-c-Si,0,260.0,236.2,1.6335,1.65,0.99,60.0,9.04,37.8,8.49,30.8,0.004972,-0.11529,46.9,1.502108520067177,9.049074850125645,1.0507815509339126e-10,0.29426580971359534,293.13576567267404,8.315700294150739,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA260P,Silfab Solar Inc,Multi-c-Si,0,260.0,234.3,1.6335,1.65,0.99,60.0,8.99,37.9,8.46,30.9,0.0045849,-0.115595,48.2,1.5121157106927055,8.997192454538078,1.1583005200021701e-10,0.2924643559826352,365.55736924923804,9.259325648336667,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA260M,Silfab Solar Inc,Mono-c-Si,0,260.0,236.2,1.6335,1.65,0.99,60.0,9.04,34.2,8.49,30.8,0.004972,-0.10431,46.9,1.5410984704526915,9.0400010896193,1.1358745430685076e-09,0.000999990324308117,8296.446165087473,-99.99999949682608,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SSA260P,Silfab Solar Inc,Multi-c-Si,0,260.0,234.3,1.6335,1.65,0.99,60.0,8.99,37.9,8.46,30.9,0.0045849,-0.115595,48.2,1.5121157106927055,8.997192454538078,1.1583005200021701e-10,0.2924643559826352,365.55736924923804,9.259325648336667,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA265M,Silfab Solar Inc,Mono-c-Si,0,265.0,240.8,1.6335,1.65,0.99,60.0,9.16,38.0,8.6,31.0,0.005038,-0.1159,46.9,1.5112907374049973,9.169362431505036,1.0862967908018735e-10,0.28689835197998725,280.6951427111089,8.492704074060944,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA265P,Silfab Solar Inc,Multi-c-Si,0,265.0,238.9,1.6335,1.65,0.99,60.0,9.12,38.5,8.55,31.0,0.004651199999999999,-0.117425,48.2,1.5284610230615643,9.131205482228445,1.0342995148866728e-10,0.3459231771138403,281.5425085265218,8.15123128264532,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA265M,Silfab Solar Inc,Mono-c-Si,0,265.0,240.8,1.6335,1.65,0.99,60.0,9.16,38.0,8.6,31.0,0.005038,-0.1159,46.9,1.5112907374049973,9.169362431505036,1.0862967908018735e-10,0.28689835197998725,280.6951427111089,8.492704074060944,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA265P,Silfab Solar Inc,Multi-c-Si,0,265.0,238.9,1.6335,1.65,0.99,60.0,9.12,38.5,8.55,31.0,0.004651199999999999,-0.117425,48.2,1.5284610230615643,9.131205482228445,1.0342995148866728e-10,0.3459231771138403,281.5425085265218,8.15123128264532,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA270M,Silfab Solar Inc,Mono-c-Si,0,270.0,244.5,1.6335,1.65,0.99,60.0,9.28,38.2,8.71,31.2,0.0038975999999999998,-0.10619600000000003,47.8,1.4958051671313777,9.290432495585588,7.411455283731335e-11,0.2857442080661458,254.17756673402718,15.541805922734452,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA270M,Silfab Solar Inc,Mono-c-Si,0,270.0,244.5,1.6335,1.65,0.99,60.0,9.28,38.2,8.71,31.2,0.0038975999999999998,-0.10619600000000003,47.8,1.4958051671313777,9.290432495585588,7.411455283731335e-11,0.2857442080661458,254.17756673402718,15.541805922734452,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA275M,Silfab Solar Inc,Mono-c-Si,0,275.0,249.2,1.6335,1.65,0.99,60.0,9.36,38.4,8.8,31.4,0.0039312,-0.10675200000000001,47.8,1.5033017873819874,9.369061034982794,7.446953519715033e-11,0.2800202604845518,289.2594217685131,15.499446737020428,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA275M,Silfab Solar Inc,Mono-c-Si,0,275.0,249.2,1.6335,1.65,0.99,60.0,9.36,38.4,8.8,31.4,0.0039312,-0.10675200000000001,47.8,1.5033017873819874,9.369061034982794,7.446953519715033e-11,0.2800202604845518,289.2594217685131,15.499446737020428,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA280M,Silfab Solar Inc,Mono-c-Si,0,280.0,253.8,1.6335,1.65,0.99,60.0,9.43,38.7,8.86,31.7,0.0039606,-0.10758600000000001,47.8,1.5169360868372785,9.439514170957628,7.737785001457319e-11,0.27289452647350715,270.4802501517833,15.790423939717005,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSA280M,Silfab Solar Inc,Mono-c-Si,0,280.0,253.8,1.6335,1.65,0.99,60.0,9.43,38.7,8.86,31.7,0.0039606,-0.10758600000000001,47.8,1.5169360868372785,9.439514170957628,7.737785001457319e-11,0.27289452647350715,270.4802501517833,15.790423939717005,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL285ML,Silfab Solar Inc,Mono-c-Si,0,285.0,257.7,1.63,,,60.0,9.47,39.1,8.91,32.0,0.0030304000000000004,-0.10908900000000002,50.08,1.475791386290979,9.480255826490351,2.9094050024185293e-11,0.29154178903851885,269.20314810175114,6.721806125556454,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL285ML-W,Silfab Solar Inc,Mono-c-Si,0,285.0,257.7,1.63,,,60.0,9.47,39.1,8.91,32.0,0.0030304000000000004,-0.10908900000000002,50.08,1.475791386290979,9.480255826490351,2.9094050024185293e-11,0.29154178903851885,269.20314810175114,6.721806125556454,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL285NL,Silfab Solar Inc,Mono-c-Si,0,285.0,257.7,1.63,,,60.0,9.47,39.1,8.91,32.0,0.0030304000000000004,-0.10908900000000002,50.08,1.475791386290979,9.480255826490351,2.9094050024185293e-11,0.29154178903851885,269.20314810175114,6.721806125556454,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL285NL-W,Silfab Solar Inc,Mono-c-Si,0,285.0,257.7,1.63,,,60.0,9.47,39.1,8.91,32.0,0.0030304000000000004,-0.10908900000000002,50.08,1.475791386290979,9.480255826490351,2.9094050024185293e-11,0.29154178903851885,269.20314810175114,6.721806125556454,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA285M,Silfab Solar Inc,Mono-c-Si,0,285.0,256.4,1.6335,1.65,0.99,60.0,9.47,39.1,8.91,32.0,0.0025189253,-0.13518434000000001,44.83,1.6858036321389736,9.474304004256956,7.948319284004503e-10,0.24178416689893228,531.9923367431654,12.28713437362433,-0.50111,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL290BL,Silfab Solar Inc,Mono-c-Si,0,290.0,258.6,1.6650690000000001,,,21.0,9.71523809523809,37.6195238095238,8.90333333333333,32.52,0.001165828571428571,-0.1060870571428571,48.2,1.6029838748400502,9.717155203134539,5.951892224212252e-10,0.01643478046741449,83.28577130024792,34.660088603192825,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL290BL-W,Silfab Solar Inc,Mono-c-Si,0,290.0,258.6,1.6650690000000001,,,21.0,9.71523809523809,37.6195238095238,8.90333333333333,32.52,0.001165828571428571,-0.1060870571428571,48.2,1.6029838748400502,9.717155203134539,5.951892224212252e-10,0.01643478046741449,83.28577130024792,34.660088603192825,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL290ML,Silfab Solar Inc,Mono-c-Si,0,290.0,262.3,1.63,,,60.0,9.54,39.6,8.97,32.4,0.0030528,-0.11048400000000001,50.08,1.494918334567124,9.550907100873847,2.94200364628738e-11,0.2942715220111137,257.3874024276399,6.7570136625905635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL290ML-W,Silfab Solar Inc,Mono-c-Si,0,290.0,262.3,1.63,,,60.0,9.54,39.6,8.97,32.4,0.0030528,-0.11048400000000001,50.08,1.494918334567124,9.550907100873847,2.94200364628738e-11,0.2942715220111137,257.3874024276399,6.7570136625905635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL290NL,Silfab Solar Inc,Mono-c-Si,0,290.0,262.3,1.63,,,60.0,9.54,39.6,8.97,32.4,0.0030528,-0.11048400000000001,50.08,1.494918334567124,9.550907100873847,2.94200364628738e-11,0.2942715220111137,257.3874024276399,6.7570136625905635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL290NL-W,Silfab Solar Inc,Mono-c-Si,0,290.0,262.3,1.63,,,60.0,9.54,39.6,8.97,32.4,0.0030528,-0.11048400000000001,50.08,1.494918334567124,9.550907100873847,2.94200364628738e-11,0.2942715220111137,257.3874024276399,6.7570136625905635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA290M,Silfab Solar Inc,Mono-c-Si,0,290.0,261.1,1.6335,1.65,0.99,60.0,9.54,39.6,8.97,32.4,0.0025375446,-0.13691304,44.83,1.7076894326956624,9.544799344382296,8.036835373207077e-10,0.24420118191209797,485.41638609548454,12.323308822427535,-0.50111,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG290P,Silfab Solar Inc,Multi-c-Si,0,290.0,262.0,1.9503,1.97,0.99,72.0,8.52,44.9,8.03,36.3,0.004686,-0.13919,47.5,1.7823457690324123,8.525741698440541,9.692158960663073e-11,0.4102644904498189,608.7839434961681,6.353457458895959,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG290P,Silfab Solar Inc,Multi-c-Si,0,290.0,262.0,1.9503,1.97,0.99,72.0,8.52,44.9,8.03,36.3,0.004686,-0.13919,47.5,1.7823457690324123,8.525741698440541,9.692158960663073e-11,0.4102644904498189,608.7839434961681,6.353457458895959,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL295BL,Silfab Solar Inc,Mono-c-Si,0,295.0,263.2,1.6650690000000001,,,21.0,9.76209523809524,38.1538095238095,8.99133333333333,32.75,0.0011714514285714288,-0.10759374285714278,48.2,1.6141460674405441,9.767020799088545,5.085937686567419e-10,0.048791699703225354,96.70152026170558,32.8891693773052,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL295BL-W,Silfab Solar Inc,Mono-c-Si,0,295.0,263.2,1.6650690000000001,,,21.0,9.76209523809524,38.1538095238095,8.99133333333333,32.75,0.0011714514285714288,-0.10759374285714278,48.2,1.6141460674405441,9.767020799088545,5.085937686567419e-10,0.048791699703225354,96.70152026170558,32.8891693773052,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL295ML,Silfab Solar Inc,Mono-c-Si,0,295.0,267.0,1.63,,,60.0,9.61,40.0,9.04,32.7,0.0030751999999999997,-0.11160000000000002,50.08,1.5090229762251763,9.620664538680519,2.914093099199489e-11,0.29858524800347064,269.0603282460214,6.609836718322988,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL295ML-W,Silfab Solar Inc,Mono-c-Si,0,295.0,267.0,1.63,,,60.0,9.61,40.0,9.04,32.7,0.0030751999999999997,-0.11160000000000002,50.08,1.5090229762251763,9.620664538680519,2.914093099199489e-11,0.29858524800347064,269.0603282460214,6.609836718322988,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL295NL,Silfab Solar Inc,Mono-c-Si,0,295.0,267.0,1.63,,,60.0,9.61,40.0,9.04,32.7,0.0030751999999999997,-0.11160000000000002,50.08,1.5090229762251763,9.620664538680519,2.914093099199489e-11,0.29858524800347064,269.0603282460214,6.609836718322988,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL295NL-W,Silfab Solar Inc,Mono-c-Si,0,295.0,267.0,1.63,,,60.0,9.61,40.0,9.04,32.7,0.0030751999999999997,-0.11160000000000002,50.08,1.5090229762251763,9.620664538680519,2.914093099199489e-11,0.29858524800347064,269.0603282460214,6.609836718322988,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA295M,Silfab Solar Inc,Mono-c-Si,0,295.0,265.7,1.6335,1.65,0.99,60.0,9.61,40.0,9.04,32.7,0.0025561639,-0.138296,44.83,1.7236618477562338,9.614518251211383,7.963071575864517e-10,0.24850320398423448,528.54897611258,12.171446045250583,-0.50111,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG295P,Silfab Solar Inc,Multi-c-Si,0,295.0,266.6,1.9503,1.97,0.99,72.0,8.62,45.1,8.12,36.5,0.0047409999999999996,-0.13981,47.5,1.7917915498684869,8.626248935825584,1.0008443957474211e-10,0.40178219021211836,554.232417178624,6.531309494131744,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG295P,Silfab Solar Inc,Multi-c-Si,0,295.0,266.6,1.9503,1.97,0.99,72.0,8.62,45.1,8.12,36.5,0.0047409999999999996,-0.13981,47.5,1.7917915498684869,8.626248935825584,1.0008443957474211e-10,0.40178219021211836,554.232417178624,6.531309494131744,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL300BL,Silfab Solar Inc,Mono-c-Si,0,300.0,267.9,1.6650690000000001,,,21.0,9.80895238095238,38.6880952380952,9.07933333333333,32.99,0.0011770742857142857,-0.10910042857142845,48.2,1.6257463870266744,9.815705920847654,4.3834361328562065e-10,0.0791807180943752,115.00338136229828,31.233929557395264,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL300BL-W,Silfab Solar Inc,Mono-c-Si,0,300.0,267.9,1.6650690000000001,,,21.0,9.80895238095238,38.6880952380952,9.07933333333333,32.99,0.0011770742857142857,-0.10910042857142845,48.2,1.6257463870266744,9.815705920847654,4.3834361328562065e-10,0.0791807180943752,115.00338136229828,31.233929557395264,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL300ML,Silfab Solar Inc,Mono-c-Si,0,300.0,271.7,1.63,,,60.0,9.71,39.85,9.16,32.8,0.0031072,-0.11118150000000002,50.08,1.5066095961107187,9.717924941162542,3.1256631795119736e-11,0.26635775659356115,326.3536990310941,7.114758253046909,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL300ML-W,Silfab Solar Inc,Mono-c-Si,0,300.0,271.7,1.63,,,60.0,9.71,39.85,9.16,32.8,0.0031072,-0.11118150000000002,50.08,1.5066095961107187,9.717924941162542,3.1256631795119736e-11,0.26635775659356115,326.3536990310941,7.114758253046909,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL300NL,Silfab Solar Inc,Mono-c-Si,0,300.0,271.7,1.63,,,60.0,9.71,39.85,9.16,32.8,0.0031072,-0.11118150000000002,50.08,1.5066095961107187,9.717924941162542,3.1256631795119736e-11,0.26635775659356115,326.3536990310941,7.114758253046909,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL300NL-W,Silfab Solar Inc,Mono-c-Si,0,300.0,271.7,1.63,,,60.0,9.71,39.85,9.16,32.8,0.0031072,-0.11118150000000002,50.08,1.5066095961107187,9.717924941162542,3.1256631795119736e-11,0.26635775659356115,326.3536990310941,7.114758253046909,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLA300M,Silfab Solar Inc,Mono-c-Si,0,300.0,272.0,1.57,1.65,0.99,60.0,9.71,39.85,9.16,32.8,0.0031072,-0.11118150000000002,50.08,1.5066095961107187,9.717924941162542,3.1256631795119736e-11,0.26635775659356115,326.3536990310941,7.114758253046909,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG300P,Silfab Solar Inc,Multi-c-Si,0,300.0,271.2,1.9503,1.97,0.99,72.0,8.72,45.3,8.21,36.7,0.004796000000000001,-0.14043,47.5,1.8012331359119773,8.726740260408851,1.0330917820372663e-10,0.3934882544062157,509.0630727974395,6.707126120057541,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG300P,Silfab Solar Inc,Multi-c-Si,0,300.0,271.2,1.9503,1.97,0.99,72.0,8.72,45.3,8.21,36.7,0.004796000000000001,-0.14043,47.5,1.8012331359119773,8.726740260408851,1.0330917820372663e-10,0.3934882544062157,509.0630727974395,6.707126120057541,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305BL,Silfab Solar Inc,Mono-c-Si,0,305.0,283.9,1.65,,,63.0,9.6859,41.7385,9.0405,33.815,0.004455514,-0.11645041500000002,43.55,1.5910508869583673,9.704320395226436,3.832995980768771e-11,0.34392994239652686,180.84688395936598,8.766068358196618,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305BL-W,Silfab Solar Inc,Mono-c-Si,0,305.0,272.5,1.6650690000000001,,,21.0,9.85580952380952,39.222380952381,9.16733333333333,33.23,0.0011826971428571423,-0.11060711428571442,48.2,1.6374890383956624,9.863397234946131,3.7939857571644534e-10,0.10893786358631245,141.50128592497128,29.644873036156685,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305ML,Silfab Solar Inc,Mono-c-Si,0,305.0,276.3,1.63,,,60.0,9.82,40.05,9.27,32.92,0.0031424000000000005,-0.1117395,50.08,1.5126118903139998,9.827554860865801,3.0789201966831624e-11,0.2702960876816388,351.3377254610328,6.8842080321240635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305ML-W,Silfab Solar Inc,Mono-c-Si,0,305.0,276.3,1.63,,,60.0,9.82,40.05,9.27,32.92,0.0031424000000000005,-0.1117395,50.08,1.5126118903139998,9.827554860865801,3.0789201966831624e-11,0.2702960876816388,351.3377254610328,6.8842080321240635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305NL,Silfab Solar Inc,Mono-c-Si,0,305.0,276.3,1.63,,,60.0,9.82,40.05,9.27,32.92,0.0031424000000000005,-0.1117395,50.08,1.5126118903139998,9.827554860865801,3.0789201966831624e-11,0.2702960876816388,351.3377254610328,6.8842080321240635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305NL-W,Silfab Solar Inc,Mono-c-Si,0,305.0,276.3,1.63,,,60.0,9.82,40.05,9.27,32.92,0.0031424000000000005,-0.1117395,50.08,1.5126118903139998,9.827554860865801,3.0789201966831624e-11,0.2702960876816388,351.3377254610328,6.8842080321240635,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL305XL,Silfab Solar Inc,Mono-c-Si,0,305.0,280.2,1.63,,,60.0,9.82,40.1,9.27,32.92,0.0015024600000000002,-0.1105557,44.7,1.5561375928278054,9.826384453514338,6.262296349477941e-11,0.2658354366132158,408.88450250688777,14.728603181278249,-0.4177,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG305P,Silfab Solar Inc,Multi-c-Si,0,305.0,275.9,1.9503,1.97,0.99,72.0,8.82,45.5,8.3,36.9,0.004851,-0.14105,47.5,1.8106706700715645,8.827215874148205,1.065961496322655e-10,0.3853764887331061,471.0476984534904,6.880950278158755,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG305P,Silfab Solar Inc,Multi-c-Si,0,305.0,275.9,1.9503,1.97,0.99,72.0,8.82,45.5,8.3,36.9,0.004851,-0.14105,47.5,1.8106706700715645,8.827215874148205,1.065961496322655e-10,0.3853764887331061,471.0476984534904,6.880950278158755,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-310BL,Silfab Solar Inc,Mono-c-Si,0,310.0,290.1,1.630476,,,63.0,9.71693333333333,41.84,9.13366666666667,33.9966666666666,0.001739331066666666,-0.11116888000000001,42.7,1.530927633031437,9.730445146053052,1.2922673250287215e-11,0.3454082690946398,248.3981220932071,4.95603097749428,-0.3689,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL310BL-W,Silfab Solar Inc,Mono-c-Si,0,310.0,277.1,1.6650690000000001,,,21.0,9.90266666666667,39.7566666666667,9.25533333333333,33.47,0.0011883200000000005,-0.1121138000000001,48.2,1.649368437203717,9.910127502648633,3.2972883794085966e-10,0.1380838265829573,183.27680534200044,28.118525290677187,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-310HL,Silfab Solar Inc,Mono-c-Si,0,310.0,289.9,1.630476,,,60.0,10.196,39.296,9.436,32.863,0.002324688,-0.09470335999999999,45.3,1.3954927654352358,10.219119074498039,5.779189590946912e-12,0.21303617796776528,93.95345271176899,8.045243616760695,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL310ML,Silfab Solar Inc,Mono-c-Si,0,310.0,281.0,1.63,,,60.0,9.93,40.25,9.38,33.05,0.0031776,-0.11229750000000002,50.08,1.5188618855732836,9.937144850025502,3.0461358652302947e-11,0.27290594370918797,379.28802824436565,6.692904992426314,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL310ML-W,Silfab Solar Inc,Mono-c-Si,0,310.0,281.0,1.63,,,60.0,9.93,40.25,9.38,33.05,0.0031776,-0.11229750000000002,50.08,1.5188618855732836,9.937144850025502,3.0461358652302947e-11,0.27290594370918797,379.28802824436565,6.692904992426314,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-310NL,Silfab Solar Inc,Mono-c-Si,0,310.0,286.4,1.630476,,,60.0,10.2089,39.68,9.56920000000001,32.438,0.0010310989,-0.09400192,46.2,1.437914621678218,10.225918758575904,1.0361436392629167e-11,0.29284331488034293,175.6654493317256,15.332551227924458,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL310NL-W,Silfab Solar Inc,Mono-c-Si,0,310.0,281.0,1.63,,,60.0,9.93,40.25,9.38,33.05,0.0031776,-0.11229750000000002,50.08,1.5188618855732836,9.937144850025502,3.0461358652302947e-11,0.27290594370918797,379.28802824436565,6.692904992426314,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG310P,Silfab Solar Inc,Multi-c-Si,0,310.0,280.5,1.9503,1.97,0.99,72.0,8.9,45.7,8.39,37.1,0.004895000000000001,-0.14167000000000002,47.5,1.8180371357678788,8.90579542550601,1.0689563100799035e-10,0.3783850549090727,581.0836645649881,6.821075892360862,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG310P,Silfab Solar Inc,Multi-c-Si,0,310.0,280.5,1.9503,1.97,0.99,72.0,8.9,45.7,8.39,37.1,0.004895000000000001,-0.14167000000000002,47.5,1.8180371357678788,8.90579542550601,1.0689563100799035e-10,0.3783850549090727,581.0836645649881,6.821075892360862,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-315BL,Silfab Solar Inc,Mono-c-Si,0,315.0,294.9,1.630476,,,63.0,9.74743333333333,41.94,9.22866666666667,34.1766666666667,0.001744790566666666,-0.11143457999999999,42.7,1.5316495024749153,9.753859705619323,1.2402284443878349e-11,0.3326006277287224,504.4840769874449,4.549727513389704,-0.3689,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL315BL-W,Silfab Solar Inc,Mono-c-Si,0,315.0,281.8,1.6650690000000001,,,21.0,9.95,40.35,9.3,33.9,0.001194,-0.113787,48.2,1.6720074381779866,9.957888477918853,3.220820897753226e-10,0.14822270247514846,186.9582434089302,27.827828110501184,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-315HL,Silfab Solar Inc,Mono-c-Si,0,315.0,294.7,1.630476,,,60.0,10.247,39.497,9.527000000000001,33.0795,0.002336316,-0.09518776999999999,45.3,1.4005202933800518,10.266638666731783,5.5963116928259035e-12,0.20766210590862644,108.35326216387499,7.697025790306725,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL315ML,Silfab Solar Inc,Mono-c-Si,0,315.0,285.7,1.63,,,60.0,9.94,40.35,9.45,33.4,0.0031808,-0.11257650000000002,50.08,1.5242149663703453,9.942051331633872,3.155293827133764e-11,0.24082889157077808,1166.9684623102794,6.962110237767391,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL315ML-W,Silfab Solar Inc,Mono-c-Si,0,315.0,285.7,1.63,,,60.0,9.94,40.35,9.45,33.4,0.0031808,-0.11257650000000002,50.08,1.5242149663703453,9.942051331633872,3.155293827133764e-11,0.24082889157077808,1166.9684623102794,6.962110237767391,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-315NL,Silfab Solar Inc,Mono-c-Si,0,315.0,291.1,1.630476,,,60.0,10.2599,39.88,9.66020000000001,32.6545,0.0010362498999999998,-0.09447572000000001,46.2,1.4432965230003276,10.272513870195795,1.0099691278858195e-11,0.2865232923569015,233.05300414475772,15.02523078670737,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL315NL-W,Silfab Solar Inc,Mono-c-Si,0,315.0,285.7,1.63,,,60.0,9.94,40.35,9.45,33.4,0.0031808,-0.11257650000000002,50.08,1.5242149663703453,9.942051331633872,3.155293827133764e-11,0.24082889157077808,1166.9684623102794,6.962110237767391,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG315M,Silfab Solar Inc,Mono-c-Si,0,315.0,286.4,1.9503,1.97,0.99,72.0,9.05,45.5,8.49,37.1,0.0036200000000000004,-0.13194999999999998,46.5,1.7923756798946726,9.060383017367604,8.420420476449862e-11,0.3545354398606424,309.0186303853445,12.126714230843708,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG315P,Silfab Solar Inc,Multi-c-Si,0,315.0,285.2,1.9503,1.97,0.99,72.0,8.98,45.9,8.48,37.3,0.004939000000000001,-0.14229,47.5,1.8254218107986957,8.984416193886771,1.0721692999704301e-10,0.37153488918066185,755.4884011834652,6.763701391897214,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG315M,Silfab Solar Inc,Mono-c-Si,0,315.0,286.4,1.9503,1.97,0.99,72.0,9.05,45.5,8.49,37.1,0.0036200000000000004,-0.13194999999999998,46.5,1.7923756798946726,9.060383017367604,8.420420476449862e-11,0.3545354398606424,309.0186303853445,12.126714230843708,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG315P,Silfab Solar Inc,Multi-c-Si,0,315.0,285.2,1.9503,1.97,0.99,72.0,8.98,45.9,8.48,37.3,0.004939000000000001,-0.14229,47.5,1.8254218107986957,8.984416193886771,1.0721692999704301e-10,0.37153488918066185,755.4884011834652,6.763701391897214,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-320BL,Silfab Solar Inc,Mono-c-Si,0,320.0,299.7,1.630476,,,63.0,9.77793333333333,42.04,9.32366666666667,34.3566666666667,0.001750250066666666,-0.11170028,42.7,1.5326359155716536,9.777937263372399,1.1956521027346979e-11,0.31998663271424965,796142.6594090237,4.183279866871696,-0.3689,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL320BL-W,Silfab Solar Inc,Mono-c-Si,0,320.0,286.4,1.6650690000000001,,,21.0,9.99,40.5,9.43,33.95,0.0011988,-0.11420999999999999,48.2,1.6671120094685397,9.993740636285027,2.78642797691687e-10,0.15980611986454263,426.7890008675165,26.260624507432063,-0.462,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-320HL,Silfab Solar Inc,Mono-c-Si,0,320.0,299.5,1.630476,,,60.0,10.298,39.698,9.618,33.296,0.0023479440000000002,-0.09567218,45.3,1.405585559283759,10.314327615517008,5.424381664090787e-12,0.20237497081999897,127.64003719161782,7.358430152034726,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL320ML,Silfab Solar Inc,Mono-c-Si,0,320.0,290.4,1.63,,,60.0,9.96,40.45,9.5,33.7,0.0031872000000000003,-0.11285550000000001,50.08,1.5305492186305207,9.960004729038454,3.3154156929333184e-11,0.21484098572570115,452494.086581898,7.359640156434371,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL320ML-W,Silfab Solar Inc,Mono-c-Si,0,320.0,290.4,1.63,,,60.0,9.96,40.45,9.5,33.7,0.0031872000000000003,-0.11285550000000001,50.08,1.5305492186305207,9.960004729038454,3.3154156929333184e-11,0.21484098572570115,452494.086581898,7.359640156434371,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-320NL,Silfab Solar Inc,Mono-c-Si,0,320.0,295.9,1.630476,,,60.0,10.3109,40.08,9.75120000000001,32.871,0.0010414009,-0.09494952,46.2,1.4487112537871583,10.31930869673749,9.852302653607661e-12,0.28030993727942244,343.72125048565124,14.726268281439681,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL320NL-W,Silfab Solar Inc,Mono-c-Si,0,320.0,290.4,1.63,,,60.0,9.96,40.45,9.5,33.7,0.0031872000000000003,-0.11285550000000001,50.08,1.5305492186305207,9.960004729038454,3.3154156929333184e-11,0.21484098572570115,452494.086581898,7.359640156434371,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG320M,Silfab Solar Inc,Mono-c-Si,0,320.0,291.0,1.9503,1.97,0.99,72.0,9.15,45.6,8.58,37.3,0.0036600000000000005,-0.13224,46.5,1.7998138572837066,9.160548008488687,8.936342238765934e-11,0.33530325286309426,290.8629514218359,12.568123863064834,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG320P,Silfab Solar Inc,Multi-c-Si,0,320.0,289.8,1.9503,1.97,0.99,72.0,9.06,46.1,8.57,37.5,0.0049830000000000004,-0.14291,47.5,1.8328240301612218,9.063077254072928,1.0755915720751131e-10,0.3648218137316227,1074.1023519344078,6.708722512301083,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG320M,Silfab Solar Inc,Mono-c-Si,0,320.0,291.0,1.9503,1.97,0.99,72.0,9.15,45.6,8.58,37.3,0.0036600000000000005,-0.13224,46.5,1.7998138572837066,9.160548008488687,8.936342238765934e-11,0.33530325286309426,290.8629514218359,12.568123863064834,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG320P,Silfab Solar Inc,Multi-c-Si,0,320.0,289.8,1.9503,1.97,0.99,72.0,9.06,46.1,8.57,37.5,0.0049830000000000004,-0.14291,47.5,1.8328240301612218,9.063077254072928,1.0755915720751131e-10,0.3648218137316227,1074.1023519344078,6.708722512301083,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-325BL,Silfab Solar Inc,Mono-c-Si,0,325.0,304.5,1.630476,,,63.0,9.8079,42.128499999999995,9.4205,34.535,0.0017556141,-0.11193542449999999,42.7,1.5424626175591447,9.807902917021352,1.3486802604183814e-11,0.2769400312047301,931175.7708981162,5.175973489534172,-0.3689,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL325BL-W,Silfab Solar Inc,Mono-c-Si,0,325.0,291.1,1.6650690000000001,,,21.0,10.05,41.65,9.58,33.97,0.001206,-0.11745299999999999,48.2,1.6876298151906384,10.050002635336044,1.9229043780136397e-10,0.26214593104114065,999992.662925532,22.469251563422894,-0.462,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-325HL,Silfab Solar Inc,Mono-c-Si,0,325.0,304.3,1.630476,,,60.0,10.349,39.899,9.709,33.5125,0.002359572,-0.09615659,45.3,1.4106867657233544,10.362180827625519,5.262521503897022e-12,0.1971730153622548,154.81148335661763,7.029024494939302,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-325NL,Silfab Solar Inc,Mono-c-Si,0,325.0,300.6,1.630476,,,60.0,10.3619,40.275,9.8422,33.0875,0.0010465519,-0.095411475,46.2,1.4540644542853234,10.366298371959795,9.634160971334986e-12,0.273688152078915,644.7679312250785,14.450690628381121,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG325M,Silfab Solar Inc,Mono-c-Si,0,325.0,295.7,1.9503,1.97,0.99,72.0,9.25,45.8,8.67,37.5,0.0037,-0.13282,46.5,1.8090585581752916,9.260894971903458,9.200828036250834e-11,0.32820302077719105,278.64944767084995,12.736215836532686,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG325M,Silfab Solar Inc,Mono-c-Si,0,325.0,295.7,1.9503,1.97,0.99,72.0,9.25,45.8,8.67,37.5,0.0037,-0.13282,46.5,1.8090585581752916,9.260894971903458,9.200828036250834e-11,0.32820302077719105,278.64944767084995,12.736215836532686,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-330BL,Silfab Solar Inc,Mono-c-Si,0,330.0,309.3,1.630476,,,63.0,9.8384,42.226,9.5155,34.715,0.0017610736,-0.112194482,42.7,1.5523167688424795,9.838402430514533,1.5110466819318213e-11,0.23193944980225434,938879.2025017635,6.118984719430427,-0.3689,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL330BL-W,Silfab Solar Inc,Mono-c-Si,0,330.0,295.7,1.6650690000000001,,,21.0,10.09,41.89,9.63,34.18,0.0012108000000000002,-0.1181298,48.2,1.6986153118902254,10.09000258285456,1.96625013886051e-10,0.25591191012420744,999999.7415862601,22.648892043791676,-0.462,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-330HL,Silfab Solar Inc,Mono-c-Si,0,330.0,309.1,1.630476,,,60.0,10.4,40.1,9.8,33.729,0.0023712000000000004,-0.096641,45.3,1.4158224201362033,10.410193389210523,5.109959491895221e-12,0.19205446432716491,195.94716358574271,6.708434804175981,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-330NL,Silfab Solar Inc,Mono-c-Si,0,330.0,305.4,1.630476,,,60.0,10.4129,40.477,9.9332,33.239,0.0010517029000000002,-0.095890013,46.2,1.4582058237643765,10.413339288774123,9.165339389140951e-12,0.2753871475503698,6527.777091342068,13.921313764532844,-0.3657,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG330M,Silfab Solar Inc,Mono-c-Si,0,330.0,300.4,1.9503,1.97,0.99,72.0,9.32,46.1,8.73,37.8,0.0037280000000000004,-0.13369,46.5,1.822926575541307,9.331297363561063,9.52525094150654e-11,0.32055558500844633,264.44914689704257,12.985748690552272,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG330M,Silfab Solar Inc,Mono-c-Si,0,330.0,300.4,1.9503,1.97,0.99,72.0,9.32,46.1,8.73,37.8,0.0037280000000000004,-0.13369,46.5,1.822926575541307,9.331297363561063,9.52525094150654e-11,0.32055558500844633,264.44914689704257,12.985748690552272,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-335BL,Silfab Solar Inc,Mono-c-Si,0,335.0,314.1,1.630476,,,63.0,9.8689,42.323499999999996,9.6105,34.894999999999996,0.0017665330999999999,-0.11245353949999999,42.7,1.5621013085173212,9.868901887804915,1.6885441579689583e-11,0.18085628173375196,945482.0621806091,7.047248309672673,-0.3689,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-335HL,Silfab Solar Inc,Mono-c-Si,0,335.0,313.9,1.630476,,,60.0,10.451,40.301,9.891,33.905499999999996,0.002382828,-0.09712541000000001,45.3,1.4201932279751108,10.458494343978417,4.8880119840565725e-12,0.19162064650551122,267.21850325416835,6.258408661350557,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-335NL,Silfab Solar Inc,Mono-c-Si,0,335.0,310.2,1.630476,,,60.0,10.4639,40.679,10.0242,33.4555,0.0010568539,-0.09636855100000001,46.2,1.4683165429412546,10.463902682189207,9.72239656871986e-12,0.25632239131306556,999997.5289313493,14.41865847443678,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SLG335M,Silfab Solar Inc,Mono-c-Si,0,335.0,305.1,1.9503,1.97,0.99,72.0,9.37,46.4,8.79,38.1,0.0037479999999999996,-0.13455999999999999,46.5,1.8347958863360154,9.38007890643092,9.592786580940124e-11,0.3138999806796481,291.8216326551463,12.995530073722701,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLGX 335 Clear,Silfab Solar Inc,Mono-c-Si,0,335.0,304.0,1.9503,1.97,0.99,72.0,9.38,47.26,8.88,37.72,0.0018760000000000003,-0.14178,46.2,1.840599624933246,9.381692299361738,6.61147674008032e-11,0.4608479022498421,2554.3676263716584,6.177829230531279,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SSG335M,Silfab Solar Inc,Mono-c-Si,0,335.0,305.1,1.9503,1.97,0.99,72.0,9.37,46.4,8.79,38.1,0.0037479999999999996,-0.13455999999999999,46.5,1.8347958863360154,9.38007890643092,9.592786580940124e-11,0.3138999806796481,291.8216326551463,12.995530073722701,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-340BL,Silfab Solar Inc,Mono-c-Si,0,340.0,318.9,1.630476,,,63.0,9.8994,42.421,9.7055,35.075,0.0017719926,-0.11271259699999998,42.7,1.5717720296985662,9.89940118748499,1.880660571756341e-11,0.1199444508656844,999927.8354752167,7.954263162301681,-0.3689,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-340HL,Silfab Solar Inc,Mono-c-Si,0,340.0,318.7,1.630476,,,60.0,10.502,40.501999999999995,9.982000000000001,34.122,0.002394456,-0.09760981999999999,45.3,1.4254008251616526,10.506745590381948,4.755001156121249e-12,0.18661757553691283,412.9849383577359,5.956311382403476,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL340MT,Silfab Solar Inc,Mono-c-Si,0,340.0,311.8,1.9,,,72.0,9.45,46.9,8.86,38.4,0.0050085,-0.13178900000000002,47.46,1.7888999101863832,9.4626604851669,3.815581332523267e-11,0.34443250535333825,257.0902444546605,8.058417215845227,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL340MT-W,Silfab Solar Inc,Mono-c-Si,0,340.0,311.8,1.9,,,72.0,9.45,46.9,8.86,38.4,0.0050085,-0.13178900000000002,47.46,1.7888999101863832,9.4626604851669,3.815581332523267e-11,0.34443250535333825,257.0902444546605,8.058417215845227,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-340NL,Silfab Solar Inc,Mono-c-Si,0,340.0,314.9,1.630476,,,60.0,10.5149,40.881,10.115200000000002,33.672,0.0010620049,-0.096847089,46.2,1.4789956602261978,10.514902695573213,1.0409883419910987e-11,0.2345776052489946,915055.9877996744,15.00733197349936,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL340NT,Silfab Solar Inc,Mono-c-Si,0,340.0,311.8,1.9,,,72.0,9.45,46.9,8.86,38.4,0.0050085,-0.13178900000000002,47.46,1.7888999101863832,9.4626604851669,3.815581332523267e-11,0.34443250535333825,257.0902444546605,8.058417215845227,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL340NT-W,Silfab Solar Inc,Mono-c-Si,0,340.0,311.8,1.9,,,72.0,9.45,46.9,8.86,38.4,0.0050085,-0.13178900000000002,47.46,1.7888999101863832,9.4626604851669,3.815581332523267e-11,0.34443250535333825,257.0902444546605,8.058417215845227,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLGX 340 Clear,Silfab Solar Inc,Mono-c-Si,0,340.0,308.7,1.9503,1.97,0.99,72.0,9.45,47.36,8.95,38.0,0.00189,-0.14208,46.2,1.8493202799126556,9.451712824066265,7.12150677260144e-11,0.43224061086923793,2384.760090431608,6.749047189636296,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLGX 340 White,Silfab Solar Inc,Mono-c-Si,0,340.0,308.7,1.9503,1.97,0.99,72.0,9.52,47.26,9.02,37.72,0.0019039999999999999,-0.14178,46.2,1.8398689719452002,9.52078169355941,6.648578300696225e-11,0.45400526502458355,5529.183847387808,6.095852376936197,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-345BL,Silfab Solar Inc,Mono-c-Si,0,345.0,323.7,1.630476,,,63.0,9.9299,42.518499999999996,9.8005,35.255,0.0017774521,-0.11297165449999999,42.7,1.5812398305061823,9.9299004243278,2.084729461676579e-11,0.040798658703636435,953679.6373803014,8.826890952604124,-0.3689,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-345HL,Silfab Solar Inc,Mono-c-Si,0,345.0,323.5,1.630476,,,60.0,10.553,40.703,10.073,34.2885,0.002406084,-0.09809423,45.3,1.4296588233930572,10.555144506679937,4.540393352886619e-12,0.18733428932540935,921.8617905192349,5.494272631497478,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL345MT,Silfab Solar Inc,Mono-c-Si,0,345.0,316.6,1.9,,,72.0,9.52,47.3,8.93,38.7,0.0050456,-0.132913,47.46,1.803044609137131,9.532436802048151,3.784639659531637e-11,0.34841368381655485,266.7002480411974,7.92063730441524,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL345MT-W,Silfab Solar Inc,Mono-c-Si,0,345.0,316.6,1.9,,,72.0,9.52,47.3,8.93,38.7,0.0050456,-0.132913,47.46,1.803044609137131,9.532436802048151,3.784639659531637e-11,0.34841368381655485,266.7002480411974,7.92063730441524,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-345NL,Silfab Solar Inc,Mono-c-Si,0,345.0,319.7,1.630476,,,60.0,10.5659,41.083,10.206199999999999,33.838499999999996,0.0010671558999999998,-0.097325627,46.2,1.488739400399411,10.565902492603836,1.0944297613993052e-11,0.21675461082718525,918815.7583389636,15.428490332857281,-0.3657,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL345NT,Silfab Solar Inc,Mono-c-Si,0,345.0,316.6,1.9,,,72.0,9.52,47.3,8.93,38.7,0.0050456,-0.132913,47.46,1.803044609137131,9.532436802048151,3.784639659531637e-11,0.34841368381655485,266.7002480411974,7.92063730441524,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL345NT-W,Silfab Solar Inc,Mono-c-Si,0,345.0,316.6,1.9,,,72.0,9.52,47.3,8.93,38.7,0.0050456,-0.132913,47.46,1.803044609137131,9.532436802048151,3.784639659531637e-11,0.34841368381655485,266.7002480411974,7.92063730441524,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG345M,Silfab Solar Inc,Mono-c-Si,0,345.0,306.5,1.9503,1.97,0.99,72.0,9.52,47.3,8.93,38.7,0.0025818239999999995,-0.16625949999999998,47.33,2.0353648558328814,9.526602238711481,7.606946450772782e-10,0.2935190381516743,423.23555285626946,10.011058212477728,-0.4968,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLGX 345 Clear,Silfab Solar Inc,Mono-c-Si,0,345.0,313.4,1.9503,1.97,0.99,72.0,9.55,47.46,9.01,38.32,0.0019100000000000005,-0.14238,46.2,1.8629675779529924,9.555950737875088,8.185011482823458e-11,0.397705240790295,638.2545152011859,7.874904898671544,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLGX 345 White,Silfab Solar Inc,Mono-c-Si,0,345.0,313.4,1.9503,1.97,0.99,72.0,9.6,47.36,9.08,38.0,0.00192,-0.14208,46.2,1.8505120483211146,9.603158038056456,7.343327362315854e-11,0.42554851091409884,1293.6089846473894,6.882541278766454,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL350MT,Silfab Solar Inc,Mono-c-Si,0,350.0,321.3,1.9,,,72.0,9.61,47.5,9.02,38.9,0.005093299999999999,-0.133475,47.46,1.8110109000134917,9.621929409278978,3.8418453292733965e-11,0.34196330603868297,275.4761236339097,7.967329008914282,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL350MT-W,Silfab Solar Inc,Mono-c-Si,0,350.0,321.3,1.9,,,72.0,9.61,47.5,9.02,38.9,0.005093299999999999,-0.133475,47.46,1.8110109000134917,9.621929409278978,3.8418453292733965e-11,0.34196330603868297,275.4761236339097,7.967329008914282,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL350NT,Silfab Solar Inc,Mono-c-Si,0,350.0,321.3,1.9,,,72.0,9.61,47.5,9.02,38.9,0.005093299999999999,-0.133475,47.46,1.8110109000134917,9.621929409278978,3.8418453292733965e-11,0.34196330603868297,275.4761236339097,7.967329008914282,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL350NT-W,Silfab Solar Inc,Mono-c-Si,0,350.0,321.3,1.9,,,72.0,9.61,47.5,9.02,38.9,0.005093299999999999,-0.133475,47.46,1.8110109000134917,9.621929409278978,3.8418453292733965e-11,0.34196330603868297,275.4761236339097,7.967329008914282,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-350NX,Silfab Solar Inc,Mono-c-Si,0,350.0,326.3,1.78,,,66.0,10.1,45.11,9.57,36.6,0.003838,-0.1186393,44.73,1.6481453912124606,10.105681098838014,1.3027035686182338e-11,0.36336918013855923,646.0068542434125,5.46543846169364,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG350M,Silfab Solar Inc,Mono-c-Si,0,350.0,311.1,1.9503,1.97,0.99,72.0,9.61,47.5,9.1,38.9,0.0026062319999999996,-0.1669625,47.33,2.034680322964349,9.610003640148095,6.982858965764341e-10,0.2887600587568062,762752.1368934313,9.134483273271952,-0.4968,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLGX 350 White,Silfab Solar Inc,Mono-c-Si,0,350.0,318.1,1.9503,1.97,0.99,72.0,9.7,47.46,9.14,38.32,0.0019399999999999999,-0.14238,46.2,1.8641309497617171,9.70729178468393,8.434225761030504e-11,0.39155901856503816,520.8769783795973,8.004991188279377,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL355MT,Silfab Solar Inc,Mono-c-Si,0,355.0,326.0,1.9,,,72.0,9.65,47.8,9.1,39.14064,0.0051145,-0.13431800000000002,47.46,1.8181559790903035,9.658088279478752,3.646290526459721e-11,0.3435612916640246,409.8976223978998,7.457181977534821,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL355MT-W,Silfab Solar Inc,Mono-c-Si,0,355.0,326.0,1.9,,,72.0,9.65,47.8,9.1,39.14064,0.0051145,-0.13431800000000002,47.46,1.8181559790903035,9.658088279478752,3.646290526459721e-11,0.3435612916640246,409.8976223978998,7.457181977534821,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL355NT,Silfab Solar Inc,Mono-c-Si,0,355.0,326.0,1.9,,,72.0,9.65,47.8,9.1,39.14064,0.0051145,-0.13431800000000002,47.46,1.8181559790903035,9.658088279478752,3.646290526459721e-11,0.3435612916640246,409.8976223978998,7.457181977534821,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL355NT-W,Silfab Solar Inc,Mono-c-Si,0,355.0,326.0,1.9,,,72.0,9.65,47.8,9.1,39.14064,0.0051145,-0.13431800000000002,47.46,1.8181559790903035,9.658088279478752,3.646290526459721e-11,0.3435612916640246,409.8976223978998,7.457181977534821,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-355NX,Silfab Solar Inc,Mono-c-Si,0,355.0,331.0,1.78,,,66.0,10.15,45.26,9.64,36.85,0.003857,-0.11903380000000001,44.73,1.654726524938139,10.153408624886747,1.336393609450103e-11,0.3473410854355435,1034.2915677632134,5.632908644732346,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-360BK,Silfab Solar Inc,Mono-c-Si,0,360.0,331.9,1.706,,,66.0,10.15,44.39,9.53,37.78,0.0010759,-0.13459048,44.0,1.791119021189112,10.155009965977586,1.7184394928658347e-10,0.11456798093472327,232.11036724597045,12.875440551925411,-0.4347,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-360HC,Silfab Solar Inc,Mono-c-Si,0,360.0,330.4,1.77,,,60.0,11.14,41.34,10.41,34.59,0.0019829200000000004,-0.11513190000000002,47.6,1.559729968515433,11.154441873658731,3.350318479302679e-11,0.18283146703505457,141.03035404076698,6.960814732382339,-0.3787,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL360MT,Silfab Solar Inc,Mono-c-Si,0,360.0,330.7,1.9,,,72.0,9.71,47.9,9.2,39.3,0.0051463,-0.134599,47.46,1.8196585348648289,9.714159686202535,3.568084755805781e-11,0.33259127748702194,776.3714094915152,7.196648696979525,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL360MT-W,Silfab Solar Inc,Mono-c-Si,0,360.0,330.7,1.9,,,72.0,9.71,47.9,9.2,39.3,0.0051463,-0.134599,47.46,1.8196585348648289,9.714159686202535,3.568084755805781e-11,0.33259127748702194,776.3714094915152,7.196648696979525,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL360NT,Silfab Solar Inc,Mono-c-Si,0,360.0,330.7,1.9,,,72.0,9.71,47.9,9.2,39.3,0.0051463,-0.134599,47.46,1.8196585348648289,9.714159686202535,3.568084755805781e-11,0.33259127748702194,776.3714094915152,7.196648696979525,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL360NT-W,Silfab Solar Inc,Mono-c-Si,0,360.0,330.7,1.9,,,72.0,9.71,47.9,9.2,39.3,0.0051463,-0.134599,47.46,1.8196585348648289,9.714159686202535,3.568084755805781e-11,0.33259127748702194,776.3714094915152,7.196648696979525,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-360NX,Silfab Solar Inc,Mono-c-Si,0,360.0,335.8,1.78,,,66.0,10.2,45.4,9.7,37.11,0.0038759999999999997,-0.11940200000000001,44.73,1.662126531381967,10.202344257391216,1.3958961997465017e-11,0.32933933991392006,1432.9746484706322,5.960448174678298,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG360M,Silfab Solar Inc,Mono-c-Si,0,360.0,320.4,1.9503,1.97,0.99,72.0,9.71,47.9,9.2,39.3,0.002633352,-0.16836849999999998,47.33,2.0542455356255465,9.7100036367383,7.253164200188228e-10,0.27881498926249687,744835.3974898614,9.37766314940945,-0.4968,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-365BK,Silfab Solar Inc,Mono-c-Si,0,365.0,340.0,1.71,,,66.0,10.24,44.57,9.61,38.07,0.004198400000000001,-0.1167734,45.87,1.6722827236872042,10.246971009572766,2.663762141203392e-11,0.12755815330035056,187.37536967385304,12.084538025873757,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-365HC,Silfab Solar Inc,Mono-c-Si,0,365.0,335.1,1.77,,,60.0,11.2,41.54,10.51,34.76,0.0019936,-0.11568890000000001,47.6,1.5640282639880008,11.211736377648736,3.20376082160336e-11,0.1829544869026409,174.59307541221312,6.511737791469469,-0.3787,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL365MT,Silfab Solar Inc,Mono-c-Si,0,365.0,335.4,1.9,,,72.0,9.81,48.1,9.26,39.5,0.0051993000000000004,-0.13516100000000003,47.46,1.8314525542847804,9.817260351687047,3.811727807469961e-11,0.3258987801387385,440.34603973354757,7.697213904900049,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL365MT-W,Silfab Solar Inc,Mono-c-Si,0,365.0,335.4,1.9,,,72.0,9.81,48.1,9.26,39.5,0.0051993000000000004,-0.13516100000000003,47.46,1.8314525542847804,9.817260351687047,3.811727807469961e-11,0.3258987801387385,440.34603973354757,7.697213904900049,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL365NT,Silfab Solar Inc,Mono-c-Si,0,365.0,335.4,1.9,,,72.0,9.81,48.1,9.26,39.5,0.0051993000000000004,-0.13516100000000003,47.46,1.8314525542847804,9.817260351687047,3.811727807469961e-11,0.3258987801387385,440.34603973354757,7.697213904900049,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL365NT-W,Silfab Solar Inc,Mono-c-Si,0,365.0,335.4,1.9,,,72.0,9.81,48.1,9.26,39.5,0.0051993000000000004,-0.13516100000000003,47.46,1.8314525542847804,9.817260351687047,3.811727807469961e-11,0.3258987801387385,440.34603973354757,7.697213904900049,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-365NX,Silfab Solar Inc,Mono-c-Si,0,365.0,340.6,1.78,,,66.0,10.25,45.54,9.77,37.4,0.003895,-0.11977020000000001,44.73,1.6693916791346313,10.2505093670965,1.4559352743100418e-11,0.3080513436162064,6198.920823146117,6.272339796513226,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG365M,Silfab Solar Inc,Mono-c-Si,0,365.0,325.1,1.95,1.97,0.99,60.0,9.71,48.1,9.26,39.5,0.002633352,-0.1690715,47.3,2.0701221317666167,9.710002351681876,7.874726312465752e-10,0.24202040643473957,999999.9236937237,10.104807534358637,-0.4968,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-370BK,Silfab Solar Inc,Mono-c-Si,0,370.0,341.4,1.706,,,66.0,10.33,44.76,9.69,38.34,0.00109498,-0.13571232,44.0,1.81339952668656,10.334081133010178,1.9304790900718618e-10,0.08389587798857795,212.35388372631294,13.777910791352948,-0.4347,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-370HC,Silfab Solar Inc,Mono-c-Si,0,370.0,339.9,1.77,,,60.0,11.25,41.75,10.6,34.95,0.0020025,-0.11627375000000001,47.6,1.569043414905814,11.25900674837719,3.0789505092570716e-11,0.18199597361178876,227.32451670635322,6.115374586395021,-0.3787,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL370MT,Silfab Solar Inc,Mono-c-Si,0,370.0,340.2,1.9,,,72.0,9.93,48.2,9.39,39.7,0.0052629,-0.13544200000000003,47.46,1.8365172085359471,9.935801894203776,3.935396027408144e-11,0.30820194052231437,527.490721259798,7.863313366634661,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL370MT-W,Silfab Solar Inc,Mono-c-Si,0,370.0,340.2,1.9,,,72.0,9.93,48.2,9.39,39.7,0.0052629,-0.13544200000000003,47.46,1.8365172085359471,9.935801894203776,3.935396027408144e-11,0.30820194052231437,527.490721259798,7.863313366634661,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL370NT,Silfab Solar Inc,Mono-c-Si,0,370.0,340.2,1.9,,,72.0,9.93,48.2,9.39,39.7,0.0052629,-0.13544200000000003,47.46,1.8365172085359471,9.935801894203776,3.935396027408144e-11,0.30820194052231437,527.490721259798,7.863313366634661,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-370NX,Silfab Solar Inc,Mono-c-Si,0,370.0,345.4,1.78,,,66.0,10.3,45.69,9.83,37.7,0.003914,-0.1201647,44.73,1.6782587723142532,10.300004266010253,1.546398233422663e-11,0.2868254166081064,692533.1105626831,6.748260798753087,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SLG370M,Silfab Solar Inc,Mono-c-Si,0,370.0,340.2,1.9,,,72.0,9.93,48.2,9.39,39.7,0.0052629,-0.13544200000000003,47.46,1.8365172085359471,9.935801894203776,3.935396027408144e-11,0.30820194052231437,527.490721259798,7.863313366634661,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-375BK,Silfab Solar Inc,Mono-c-Si,0,375.0,349.6,1.71,,,66.0,10.41,44.94,9.76,38.51,0.0042681,-0.1177428,45.87,1.6897756929524546,10.416623293559518,2.862565903180002e-11,0.11172796234868923,175.60569873738365,12.594423142838275,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-375HC,Silfab Solar Inc,Mono-c-Si,0,375.0,344.6,1.77,,,60.0,11.3,41.96,10.68,35.14,0.0020114,-0.11685860000000002,47.6,1.5748457766385533,11.306937190139294,2.996071173313433e-11,0.18092740967699303,294.7129473524075,5.830906263994952,-0.3787,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL375MT,Silfab Solar Inc,Mono-c-Si,0,375.0,344.9,1.9,,,72.0,9.955,48.3,9.445,39.75,0.005276149999999999,-0.135723,47.46,1.836575905969462,9.958181306433287,3.7543457919970405e-11,0.31225869921821986,977.1254076820134,7.417503017131258,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL375MT-W,Silfab Solar Inc,Mono-c-Si,0,375.0,344.9,1.9,,,72.0,9.955,48.3,9.445,39.75,0.005276149999999999,-0.135723,47.46,1.836575905969462,9.958181306433287,3.7543457919970405e-11,0.31225869921821986,977.1254076820134,7.417503017131258,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL375NT,Silfab Solar Inc,Mono-c-Si,0,375.0,344.9,1.9,,,72.0,9.955,48.3,9.445,39.75,0.005276149999999999,-0.135723,47.46,1.836575905969462,9.958181306433287,3.7543457919970405e-11,0.31225869921821986,977.1254076820134,7.417503017131258,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL375NT-W,Silfab Solar Inc,Mono-c-Si,0,375.0,344.9,1.9,,,72.0,9.955,48.3,9.445,39.75,0.005276149999999999,-0.135723,47.46,1.836575905969462,9.958181306433287,3.7543457919970405e-11,0.31225869921821986,977.1254076820134,7.417503017131258,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-375NU,Silfab Solar Inc,Mono-c-Si,0,375.0,346.0,1.96,,,72.0,9.995000000000001,47.68,9.795,38.37949999999999,0.0021989,-0.1397024,44.3,1.845703417519421,9.99514878120216,6.032901838868194e-11,0.20993647420211176,14103.367280652026,7.347590827208146,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-375NX,Silfab Solar Inc,Mono-c-Si,0,375.0,350.2,1.78,,,66.0,10.35,45.83,9.89,37.94,0.003933,-0.1205329,44.73,1.6866169477598356,10.350004113112446,1.6366945916863084e-11,0.2716144456565506,683486.6275078475,7.198225429359587,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-380BK,Silfab Solar Inc,Mono-c-Si,0,380.0,354.4,1.71,,,66.0,10.5,45.13,9.79,38.88,0.004305,-0.11824060000000002,45.87,1.7064250721946022,10.506555316649855,3.3250370979195576e-11,0.08554200484478167,137.01718801031495,13.913959490164345,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-380HC,Silfab Solar Inc,Mono-c-Si,0,380.0,349.4,1.77,,,60.0,11.36,42.17,10.77,35.32,0.00202208,-0.11744345000000002,47.6,1.5804054538385293,11.364883546295022,2.906865671721117e-11,0.18078083754736954,420.5284895602333,5.514633496309666,-0.3787,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-380HC+,Silfab Solar Inc,Mono-c-Si,0,380.0,348.4,1.92,,,66.0,10.28,45.35,9.905,38.39,0.00314568,-0.13759190000000002,46.3,1.7880169074698937,10.280090774787332,9.924175025368377e-11,0.10346348832975963,11716.971334980355,7.53004561598009,-0.4024,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL380MT,Silfab Solar Inc,Mono-c-Si,0,380.0,349.7,1.9,,,72.0,9.98,48.4,9.54,39.9,0.0052894,-0.136004,47.46,1.8410918479640572,9.980002879863473,3.820060859898898e-11,0.2885489092146599,999999.697174893,7.530037954570664,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL380MT-W,Silfab Solar Inc,Mono-c-Si,0,380.0,349.7,1.9,,,72.0,9.98,48.4,9.54,39.9,0.0052894,-0.136004,47.46,1.8410918479640572,9.980002879863473,3.820060859898898e-11,0.2885489092146599,999999.697174893,7.530037954570664,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-380NT,Silfab Solar Inc,Mono-c-Si,0,380.0,351.1,1.901,,,72.0,10.086,47.882,9.846,38.666,0.00221892,-0.14029425999999998,44.3,1.8537356598697254,10.086324168127456,6.103990567167094e-11,0.2280018322952663,7093.895055234752,7.371627145292175,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL380NT-W,Silfab Solar Inc,Mono-c-Si,0,380.0,349.7,1.9,,,72.0,9.98,48.4,9.54,39.9,0.0052894,-0.136004,47.46,1.8410918479640572,9.980002879863473,3.820060859898898e-11,0.2885489092146599,999999.697174893,7.530037954570664,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-380NU,Silfab Solar Inc,Mono-c-Si,0,380.0,350.8,1.96,,,72.0,10.086,47.882,9.846,38.666,0.00221892,-0.14029425999999998,44.3,1.8537356598697254,10.086324168127456,6.103990567167094e-11,0.2280018322952663,7093.895055234752,7.371627145292175,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-380NX,Silfab Solar Inc,Mono-c-Si,0,380.0,355.0,1.78,,,66.0,10.41,45.98,9.96,38.21,0.0039558,-0.1209274,44.73,1.6957824633578407,10.410003928544063,1.7452012092708658e-11,0.2539059494452718,672820.5037521884,7.706634816706594,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-385HC,Silfab Solar Inc,Mono-c-Si,0,385.0,354.1,1.77,,,60.0,11.41,42.38,10.86,35.5,0.00203098,-0.11802830000000002,47.6,1.5853184776217182,11.412234966449427,2.790703045548322e-11,0.18087783083370648,923.4215212954134,5.113602185530055,-0.3787,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-385HC+,Silfab Solar Inc,Mono-c-Si,0,385.0,353.2,1.92,,,66.0,10.42,45.39,10.005,38.49,0.00318852,-0.13771326,46.3,1.787641855503845,10.420001185201333,9.788094948335829e-11,0.11373393001058045,999998.5755622884,7.292941488016432,-0.4024,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-385HU,Silfab Solar Inc,Mono-c-Si,0,385.0,361.2,1.96,,,72.0,10.0498,48.111,9.6824,39.80049999999999,0.002110458,-0.11594750999999999,44.6,1.6753913180446471,10.04980295362007,3.394963188219014e-12,0.285744401637052,972259.9828832885,3.435170250187101,-0.3248,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-385NT,Silfab Solar Inc,Mono-c-Si,0,385.0,355.8,1.901,,,72.0,10.177,48.084,9.897,38.9525,0.00223894,-0.14088612,44.3,1.8607991901772563,10.177178593921552,6.096627755236448e-11,0.24527487333268141,13976.740950224961,7.28267275463447,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-385NU,Silfab Solar Inc,Mono-c-Si,0,385.0,355.5,1.96,,,72.0,10.177,48.084,9.897,38.9525,0.00223894,-0.14088612,44.3,1.8607991901772563,10.177178593921552,6.096627755236448e-11,0.24527487333268141,13976.740950224961,7.28267275463447,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-390BG,Silfab Solar Inc,Mono-c-Si,0,390.0,364.0,1.86,,,66.0,11.10219296,45.05043992,10.48475063,37.2222269,0.0048849649024,-0.11803215259040001,45.39,1.656338895398038,11.111444018657735,1.6894959844858146e-11,0.25810706847783305,309.75416221561574,7.242286758202657,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-390HC+,Silfab Solar Inc,Mono-c-Si,0,390.0,357.9,1.92,,,66.0,10.562,45.43,10.11,38.59,0.0032319719999999996,-0.13783462,46.3,1.7882035047643194,10.562002235944165,9.779673855722053e-11,0.13171252310298942,622206.632756817,7.169008644884741,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-390HU,Silfab Solar Inc,Mono-c-Si,0,390.0,366.0,1.96,,,72.0,10.1278,48.312,9.7514,40.016999999999996,0.0021268380000000003,-0.11643192,44.6,1.6828145129403511,10.127802944779488,3.446137965723476e-12,0.2824566242196656,971440.038484625,3.49645522204985,-0.3248,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-390NT,Silfab Solar Inc,Mono-c-Si,0,390.0,360.6,1.901,,,72.0,10.268,48.286,9.948,39.239,0.00225896,-0.14147798,44.3,1.8683987149040249,10.268241836017701,6.13210923920046e-11,0.2559437295251522,10867.00100917498,7.256340759608251,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-390NU,Silfab Solar Inc,Mono-c-Si,0,390.0,360.3,1.96,,,72.0,10.268,48.286,9.948,39.239,0.00225896,-0.14147798,44.3,1.8683987149040249,10.268241836017701,6.13210923920046e-11,0.2559437295251522,10867.00100917498,7.256340759608251,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-395BG,Silfab Solar Inc,Mono-c-Si,0,395.0,368.8,1.86,,,66.0,11.15131771,45.26627391,10.55485669,37.43435,0.0049065797924,-0.11859763764420002,45.39,1.6632413007764053,11.158589926729059,1.6728071156162046e-11,0.2546293894914557,390.4522315261048,7.108013007917577,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-395HC+,Silfab Solar Inc,Mono-c-Si,0,395.0,362.6,1.92,,,66.0,10.706,45.47,10.21,38.69,0.003276036,-0.13795598,46.3,1.7893766730502736,10.706284756792463,9.847951821855323e-11,0.12284344999012406,4618.546436991602,7.115736209781768,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-395HU,Silfab Solar Inc,Mono-c-Si,0,395.0,370.8,1.96,,,72.0,10.2058,48.513,9.8204,40.2335,0.002143218,-0.11691633,44.6,1.5039350789717283,10.205950030397329,9.990000081614448e-14,0.3474473648058532,23635.06844801355,-23.27104987014264,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-395NT,Silfab Solar Inc,Mono-c-Si,0,395.0,365.4,1.901,,,72.0,10.359,48.488,9.998999999999999,39.528499999999994,0.00227898,-0.14206984,44.3,1.8758494918215967,10.35923349655384,6.155580270000512e-11,0.26409220337746736,11716.376198027772,7.213169722932935,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-395NU,Silfab Solar Inc,Mono-c-Si,0,395.0,365.0,1.96,,,72.0,10.359,48.488,9.998999999999999,39.528499999999994,0.00227898,-0.14206984,44.3,1.8758494918215967,10.35923349655384,6.155580270000512e-11,0.26409220337746736,11716.376198027772,7.213169722932935,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-400BG,Silfab Solar Inc,Mono-c-Si,0,400.0,373.6,1.86,,,66.0,11.20065982,45.48314194,10.62543151,37.64768195,0.0049282903207999995,-0.11916583188280001,45.39,1.6702115041480368,11.205988427531697,1.657318362547847e-11,0.25115233382532304,527.9187622351725,6.979259865332995,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-400HC+,Silfab Solar Inc,Mono-c-Si,0,400.0,367.4,1.92,,,66.0,10.85,45.51,10.32,38.79,0.0033201,-0.13807734,46.3,1.788778829320982,10.8500039583487,9.685695938562468e-11,0.114571884720485,314031.7179170286,6.854923830448713,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-400HU,Silfab Solar Inc,Mono-c-Si,0,400.0,375.6,1.96,,,72.0,10.2838,48.714,9.889399999999998,40.449999999999996,0.002159598,-0.11740074,44.6,1.6976649172843303,10.283802924689915,3.5497522641955017e-12,0.2758319279602309,969884.9850825501,3.6180841417467504,-0.3248,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-400NT,Silfab Solar Inc,Mono-c-Si,0,400.0,370.1,1.901,,,72.0,10.45,48.69,10.05,39.805,0.002299,-0.1426617,44.3,1.883045513821113,10.450242986276605,6.157142216861928e-11,0.27118820724418485,11662.877716841185,7.140138747850081,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-400NU,Silfab Solar Inc,Mono-c-Si,0,400.0,369.8,1.96,,,72.0,10.45,48.69,10.05,39.805,0.002299,-0.1426617,44.3,1.883045513821113,10.450242986276605,6.157142216861928e-11,0.27118820724418485,11662.877716841185,7.140138747850081,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-400QD,Silfab Solar Inc,Mono-c-Si,0,400.0,376.8,1.89,,,54.0,12.78367713,38.70601009,12.22264384,32.74081175,0.005113470851999999,-0.09212030401419999,45.85,1.332624554206216,12.783681343621836,3.1087976400785886e-12,0.13994844771888024,424589.47980620415,1.6792643341117555,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-405BG,Silfab Solar Inc,Mono-c-Si,0,405.0,378.4,1.86,,,66.0,11.25022026,45.70104898,10.69647823,37.86222964,0.0049500969143999995,-0.1197367483276,45.39,1.6771982190800978,11.253642038113753,1.6416145786815528e-11,0.24768664625291215,814.3512768140854,6.848702391628442,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-405HC+,Silfab Solar Inc,Mono-c-Si,0,405.0,372.1,1.92,,,66.0,11.0,45.55,10.415,38.89,0.003366,-0.13819869999999998,46.3,1.7878859600122619,11.00000351052187,9.481122805867076e-11,0.10636656872817246,333301.28679460526,6.55438566054757,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-405HU,Silfab Solar Inc,Mono-c-Si,0,405.0,380.4,1.96,,,72.0,10.361799999999999,48.91499999999999,9.9584,40.66649999999999,0.002175978,-0.11788514999999998,44.6,1.705092105549429,10.361802913508726,3.602192399406659e-12,0.2725018865999923,969148.451409355,3.6784327963278263,-0.3248,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-405NT,Silfab Solar Inc,Mono-c-Si,0,405.0,374.9,1.901,,,72.0,10.541,48.891999999999996,10.100999999999999,40.1015,0.0023190199999999998,-0.14325355999999997,44.3,1.8900850033616456,10.54100290861486,6.147739242815536e-11,0.2759081678416991,999985.5959487316,7.051079244428107,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-405NU,Silfab Solar Inc,Mono-c-Si,0,405.0,374.5,1.96,,,72.0,10.541,48.891999999999996,10.100999999999999,40.1015,0.0023190199999999998,-0.14325355999999997,44.3,1.8900850033616456,10.54100290861486,6.147739242815536e-11,0.2759081678416991,999985.5959487316,7.051079244428107,-0.4087,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-405QD,Silfab Solar Inc,Mono-c-Si,0,405.0,381.6,1.89,,,54.0,12.958,38.74,12.34,32.825,0.0051832,-0.0922012,45.85,1.3402658879785825,12.962791870217306,3.5966502151262396e-12,0.13229481228066226,357.74678844070274,2.8280724093602356,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-410BG,Silfab Solar Inc,Mono-c-Si,0,410.0,383.2,1.86,,,66.0,11.3,45.92,10.768,38.078,0.004972,-0.12031040000000001,45.39,1.6842188083071299,11.301551649043631,1.6261626925828275e-11,0.24422873518390995,1778.6157204657857,6.71878611985393,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-410HC+,Silfab Solar Inc,Mono-c-Si,0,410.0,376.9,1.92,,,66.0,11.15,45.59,10.52,38.99,0.0034119,-0.13832006000000002,46.3,1.809186361520541,11.153646045145685,1.2512221218628238e-10,0.09398366180790162,287.4122002070784,8.889169516923976,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-410HU,Silfab Solar Inc,Mono-c-Si,0,410.0,385.2,1.96,,,72.0,10.4398,49.116,10.0274,40.882999999999996,0.002192358,-0.11836956,44.6,1.7126868350370286,10.439804472223734,3.665236051520331e-12,0.2846363222616623,664447.44816949,3.762117287976718,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-410NT,Silfab Solar Inc,Mono-c-Si,0,410.0,379.7,1.901,,,72.0,10.632000000000001,49.094,10.152000000000001,40.385,0.00233904,-0.14384542,44.3,1.897647889857019,10.632004715076897,6.18003145487335e-11,0.2918870603601734,658210.1090625228,7.022258380251258,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-410NU,Silfab Solar Inc,Mono-c-Si,0,410.0,379.3,1.96,,,72.0,10.632000000000001,49.094,10.152000000000001,40.385,0.00233904,-0.14384542,44.3,1.897647889857019,10.632004715076897,6.18003145487335e-11,0.2918870603601734,658210.1090625228,7.022258380251258,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-410QD,Silfab Solar Inc,Mono-c-Si,0,410.0,386.5,1.89,,,54.0,13.1347,38.77401976,12.45848296,32.90940473,0.005253880000000001,-0.0922821670288,45.85,1.3449366596298902,13.142106433706113,3.911205876290252e-12,0.1252518355427477,222.12381180480946,3.4453265606899515,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-415BG,Silfab Solar Inc,Mono-c-Si,0,415.0,388.0,1.86,,,66.0,11.35,46.14,10.84,38.295,0.004994,-0.12088680000000002,45.39,1.6917766262665845,11.350004546732562,1.623433460297685e-11,0.24068563149561975,600831.6974579005,6.6578154775217495,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-415HC+,Silfab Solar Inc,Mono-c-Si,0,415.0,381.6,1.92,,,66.0,11.302,45.63,10.62,39.09,0.0034584119999999997,-0.13844142,46.3,1.7873918783297627,11.302002315876315,9.2496883685151e-11,0.09028660209444876,440632.57814235357,6.112105439919661,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-415HU,Silfab Solar Inc,Mono-c-Si,0,415.0,390.0,1.96,,,72.0,10.5178,49.31699999999999,10.0964,41.0995,0.002208738,-0.11885396999999998,44.6,1.720085613606461,10.51780448168678,3.716699808622963e-12,0.2783255927187832,653187.9512109589,3.817360993303983,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-415NT,Silfab Solar Inc,Mono-c-Si,0,415.0,384.5,1.901,,,72.0,10.722999999999999,49.296,10.203,40.671499999999995,0.0023590599999999996,-0.14443728,44.3,1.9057649503307108,10.723470110256676,6.254908913929434e-11,0.27783669560810564,6337.3207097252425,7.0550718907834185,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-415NU,Silfab Solar Inc,Mono-c-Si,0,415.0,384.1,1.96,,,72.0,10.722999999999999,49.296,10.203,40.671499999999995,0.0023590599999999996,-0.14443728,44.3,1.9057649503307108,10.723470110256676,6.254908913929434e-11,0.27783669560810564,6337.3207097252425,7.0550718907834185,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-415QD,Silfab Solar Inc,Mono-c-Si,0,415.0,391.3,1.89,,,54.0,13.313,38.80806939,12.57810353,32.9940265,0.0053252,-0.0923632051482,45.85,1.3496211875424304,13.32278688760826,4.2522346501360646e-12,0.11830995938009876,160.935790201985,4.063771728472754,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-420BG,Silfab Solar Inc,Mono-c-Si,0,420.0,392.8,1.86,,,66.0,11.40022124,46.36105401,10.91248143,38.51323665,0.005016097345600001,-0.1214659615062,45.39,1.7020814872151437,11.400225725934142,1.689114327116268e-11,0.23665430752269562,601424.5394819365,6.963396666753855,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-420HC+,Silfab Solar Inc,Mono-c-Si,0,420.0,386.4,1.92,,,66.0,11.456,45.67,10.72,39.19,0.0035055359999999996,-0.13856278000000002,46.3,1.7868409035419042,11.456002053337109,9.096288970350669e-11,0.08250203627336988,460310.44458518625,5.854586697645665,-0.4024,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-420HU,Silfab Solar Inc,Mono-c-Si,0,420.0,394.9,1.96,,,72.0,10.5958,49.518,10.1654,41.315999999999995,0.0022251180000000003,-0.11933838,44.6,1.7274865138153725,10.595804487097642,3.768601750945955e-12,0.27210175799651193,642541.4525341034,3.872455723154784,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-420NT,Silfab Solar Inc,Mono-c-Si,0,420.0,389.2,1.901,,,72.0,10.814,49.498000000000005,10.254000000000001,40.958,0.00237908,-0.14502914,44.3,1.9198236919527643,10.817325921782132,6.832150561026745e-11,0.26278721950635525,854.4341617215683,7.7596467016868615,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-420NU,Silfab Solar Inc,Mono-c-Si,0,420.0,388.9,1.96,,,72.0,10.814,49.498000000000005,10.254000000000001,40.958,0.00237908,-0.14502914,44.3,1.9198236919527643,10.817325921782132,6.832150561026745e-11,0.26278721950635525,854.4341617215683,7.7596467016868615,-0.4087,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-420QD,Silfab Solar Inc,Mono-c-Si,0,420.0,396.1,1.89,,,54.0,13.495,38.84214893,12.69887265,33.07886586,0.005397999999999999,-0.0924443144534,45.85,1.3544170686626225,13.507023249481009,4.631313948345447e-12,0.11143478334518851,125.07537206877883,4.700378740269247,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-425HU,Silfab Solar Inc,Mono-c-Si,0,425.0,399.7,1.96,,,72.0,10.6738,49.718999999999994,10.2344,41.53249999999999,0.002241498,-0.11982278999999998,44.6,1.7350686121444505,10.673893959136262,3.831731957036032e-12,0.26592700754881293,30209.43599029719,3.9519897982910246,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-425QD,Silfab Solar Inc,Mono-c-Si,0,425.0,401.0,1.89,,,54.0,13.679,38.87625839,12.81580134,33.16392337,0.0054716,-0.09252549496819999,45.85,1.3594949624462824,13.693244711095907,5.069037965488628e-12,0.1046091369998332,100.45471470507665,5.384750507759192,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-430HU,Silfab Solar Inc,Mono-c-Si,0,430.0,404.5,1.96,,,72.0,10.7518,49.92,10.3034,41.748999999999995,0.002257878,-0.1203072,44.6,1.7422945058677195,10.751804491155083,3.873718028997955e-12,0.25990769339482156,622219.6871004932,3.982181163946115,-0.3248,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-430QD,Silfab Solar Inc,Mono-c-Si,0,430.0,405.8,1.89,,,54.0,13.865,38.9103978,12.93385272,33.24919959,0.005546,-0.092606746764,45.85,1.3646086678877256,13.881189216542374,5.548796239039213e-12,0.09787026223159062,83.81944755796493,6.07400852857676,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-435QD,Silfab Solar Inc,Mono-c-Si,0,435.0,410.6,1.89,,,54.0,14.05,38.94,13.05,33.33,0.005620000000000001,-0.09267719999999999,45.85,1.3695938331402957,14.06786481585186,6.072751185684955e-12,0.09129239757290679,71.79800772713298,6.7673692975009905,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-440QD,Silfab Solar Inc,Mono-c-Si,0,440.0,415.5,1.89,,,54.0,14.25,38.97,13.17,33.42,0.005700000000000001,-0.0927486,45.85,1.3752786511552841,14.269431406837068,6.737225594737846e-12,0.08387290215366648,61.508096983671535,7.579923641764319,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-460HN,Silfab Solar Inc,Mono-c-Si,0,460.0,423.0,2.277,,,78.0,11.06,52.8836187526402,10.37,44.3926108121848,0.0072443,-0.16013159758299456,47.1,2.099751654883186,11.06912593182476,1.2513725579183425e-10,0.1979502098667568,239.90200872732905,8.763111443029288,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-465HN,Silfab Solar Inc,Mono-c-Si,0,465.0,427.8,2.277,,,78.0,11.1106650886995,53.0618114028737,10.450014346,44.5313067620555,0.007277485633098173,-0.1606711649279016,47.1,2.077834423734352,11.110671462257946,9.018289513891095e-11,0.2045005396618317,356504.2725770844,5.819754519556964,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-470HN,Silfab Solar Inc,Mono-c-Si,0,470.0,432.5,2.277,,,78.0,11.1602220248668,53.2406044776119,10.52474,44.6704360400445,0.007309945426287753,-0.16121255035820886,47.1,2.0868350702926755,11.160229028945512,9.282864758121073e-11,0.20502038105916362,326685.8525411709,6.02925277542825,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-475HN,Silfab Solar Inc,Mono-c-Si,0,475.0,437.3,2.277,,,78.0,11.21,53.42,10.6,44.81,0.007342550000000001,-0.16175576,47.1,2.095879203105702,11.210007852767173,9.555496744179713e-11,0.20553340481649024,293410.6602302755,6.239422974028511,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-480HM,Silfab Solar Inc,Mono-c-Si,0,480.0,437.1,2.3,,,66.0,13.36,45.3,12.76,37.64,0.00805608,-0.16584329999999997,45.2,1.9622604904704295,13.3600036806352,1.2584803663723975e-09,0.1468311082371327,533281.927014567,6.61022090725566,-0.4658,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-480HN,Silfab Solar Inc,Mono-c-Si,0,480.0,442.0,2.277,,,78.0,11.26,53.6,10.68,44.95,0.0073753,-0.16230080000000002,47.1,2.1052937150644837,11.260007016837108,9.875415689803514e-11,0.20597368424483137,330537.70940473245,6.484288725202165,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-485HN,Silfab Solar Inc,Mono-c-Si,0,485.0,446.8,2.277,,,78.0,11.31,53.78,10.76,45.09,0.007408050000000001,-0.16284584000000002,47.1,2.1147049921298198,11.310007019978427,1.020284276600504e-10,0.2064068213831013,332555.0891552443,6.7271757947565725,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-490HM,Silfab Solar Inc,Mono-c-Si,0,490.0,446.5,2.3,,,66.0,13.41941816,45.53806186,12.82604741,38.21420355,0.00809190915048,-0.16671484446946,45.2,1.9501203116868875,13.419421176023578,9.690402564564245e-10,0.11789901945841916,524787.7884759913,4.3377238233930075,-0.4658,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-490HN,Silfab Solar Inc,Mono-c-Si,0,490.0,451.5,2.277,,,78.0,11.3606700402104,53.9618215869074,10.8332865632221,45.231313573674,0.0074412388763378115,-0.1633963957651556,47.1,2.123587274268101,11.360674167448602,1.0463507356404528e-10,0.20696899656014717,569733.8363542815,6.906367361684874,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-495HM,Silfab Solar Inc,Mono-c-Si,0,495.0,451.3,2.3,,,66.0,13.44771638,45.65839144,12.85692388,38.50393349,0.00810897297714,-0.16715537106184,45.2,1.9936276355355416,13.447717347462996,1.5218179265056995e-09,0.07187174917044753,999999.7278516152,8.209747002615888,-0.4658,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-495HN,Silfab Solar Inc,Mono-c-Si,0,495.0,456.3,2.277,,,78.0,11.411342074288,54.1436472680314,10.9107529088751,45.3726298847723,0.007474429058658641,-0.16394696392759908,47.1,2.1328041656994268,11.41134621787869,1.0771505225085242e-10,0.20745599235205642,571358.6761476905,7.118792690876812,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-500HM,Silfab Solar Inc,Mono-c-Si,0,500.0,456.0,2.3,,,66.0,13.476,45.779,12.887,38.795,0.008126028,-0.167596919,45.2,2.003616662439445,13.4760010571893,1.6096068014409116e-09,0.07836683267712441,999999.9434020986,8.685347647304011,-0.4658,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-500HN,Silfab Solar Inc,Mono-c-Si,0,500.0,461.1,2.277,,,78.0,11.4622401210065,54.3260856152468,10.9887731985851,45.5143877107903,0.007507767279259258,-0.1644993872429673,47.1,2.1420649627469697,11.462244280090292,1.1088818225733739e-10,0.20793653150034672,573094.5496344389,7.331827895542658,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-505HM,Silfab Solar Inc,Mono-c-Si,0,505.0,460.7,2.3,,,66.0,13.50449195,45.90000532,12.9189,39.09,0.00814320864585,-0.16803991947651997,45.2,2.0058365648202017,13.504493050696048,1.557467173749397e-09,0.06238365727783962,765953.7614443174,8.376376586948286,-0.4658,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-505HN,Silfab Solar Inc,Mono-c-Si,0,505.0,465.8,2.277,,,78.0,11.5133651884508,54.509138692947,11.0673513934788,45.65,0.007541254198435274,-0.16505367196224352,47.1,2.15122764869129,11.513369374695413,1.1396625208087711e-10,0.20909576758623405,575105.208950557,7.530914334877189,-0.3777,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-510HM,Silfab Solar Inc,Mono-c-Si,0,510.0,465.5,2.3,,,66.0,13.53296957,46.0212913,12.95,39.38637,0.00816038065071,-0.16848394744929998,45.2,2.0250955332541887,13.532969848635544,1.8274103752305203e-09,0.020569408218901457,999999.9587108806,9.774743098015477,-0.4658,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-510QM,Silfab Solar Inc,Mono-c-Si,0,510.0,482.6,2.3,,,66.0,13.59019722,47.30076154,12.78025345,39.91596362,0.0043488631104000005,-0.1144678429268,44.6,1.6323304972021293,13.605703694154332,3.456760204114283e-12,0.1691043819363821,148.20660583885066,0.5680309363964251,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-515HM,Silfab Solar Inc,Mono-c-Si,0,515.0,470.2,2.3,,,66.0,13.56150724,46.14289777,12.98117487,39.684987,0.00817758886572,-0.16892914873596998,45.2,2.035708860566972,13.56150728443635,1.942063052597981e-09,0.0032713926158916998,999999.0183626543,10.300550100706147,-0.4658,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-515QM,Silfab Solar Inc,Mono-c-Si,0,515.0,487.4,2.3,,,66.0,13.62006579,47.41025404,12.81308456,40.19699252,0.0043584210528,-0.1147328147768,44.6,1.639472404536629,13.633987108328963,3.676646985488568e-12,0.1524455676008053,149.14669806363054,1.0621528241449842,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-515XM,Silfab Solar Inc,Mono-c-Si,1,515.0,481.8,2.3,,,66.0,13.61,47.41,12.81,40.19,0.006805,-0.1242142,48.7,1.6777123428715348,13.622395307569839,7.114296295501082e-12,0.14624611744259694,160.5776742459057,-1.7544138835214742,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-520HM,Silfab Solar Inc,Mono-c-Si,0,520.0,475.0,2.3,,,66.0,13.59010508,46.26482556,13.007,39.98586803,0.008194833363240001,-0.16937552637515998,45.2,2.0457353535066547,13.590105093701862,2.0489960522410976e-09,0.0009999900183061481,999999.7345074875,10.763710746322777,-0.4658,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-520QM,Silfab Solar Inc,Mono-c-Si,0,520.0,492.3,2.3,,,66.0,13.65,47.52,12.85,40.48,0.004368,-0.11499840000000001,44.6,1.6464054957614838,13.662146998811343,3.895066004659527e-12,0.13576673295698308,152.56574360004873,1.5237348327366043,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-520XM,Silfab Solar Inc,Mono-c-Si,1,520.0,486.6,2.3,,,66.0,13.65,47.52,12.85,40.48,0.006825000000000001,-0.12450240000000003,48.7,1.6854990967072547,13.660998404600548,7.615040254781889e-12,0.1287410619292283,159.7791281124277,-1.2276862250918161,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-525QM,Silfab Solar Inc,Mono-c-Si,0,525.0,497.1,2.3,,,66.0,13.68,47.63,12.879,40.765,0.004377600000000001,-0.11526460000000001,44.6,1.6538487982860914,13.690764415075245,4.157737770073328e-12,0.11895180410046324,151.17037663224545,2.0533703354553468,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-525XM,Silfab Solar Inc,Mono-c-Si,1,525.0,491.4,2.3,,,66.0,13.68,47.63,12.88,40.77,0.006840000000000001,-0.12479060000000002,48.7,1.6933107693601632,13.68960006776403,8.143131249927212e-12,0.11143063284637102,158.7875311730474,-0.7002124516346313,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-530QM,Silfab Solar Inc,Mono-c-Si,0,530.0,502.0,2.3,,,66.0,13.71006593,47.74025463,12.91208477,41.05200655,0.0043872210976,-0.1155314162046,44.6,1.6610834711124491,13.719261209348423,4.420578682309586e-12,0.10211611824242157,152.25407078584553,2.5504571519214743,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-530XM,Silfab Solar Inc,Mono-c-Si,1,530.0,496.2,2.3,,,66.0,13.71,47.74,12.91,41.05,0.006855,-0.12507880000000002,48.7,1.7009064267030678,13.718252071940086,8.671893433901353e-12,0.09509277303716505,157.98722181419328,-0.20416229184517176,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-535QM,Silfab Solar Inc,Mono-c-Si,0,535.0,506.8,2.3,,,66.0,13.74019795,47.85076448,12.94525454,41.34103377,0.004396863344,-0.1157988500416,44.6,1.6683492506353717,13.747831962656337,4.6994512647041375e-12,0.08522074218565809,153.3858955267881,3.0485230238799783,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-535XM,Silfab Solar Inc,Mono-c-Si,1,535.0,501.0,2.3,,,66.0,13.74,47.85,12.94,41.34,0.00687,-0.125367,48.7,1.7086948613617436,13.746816049662279,9.259049249348574e-12,0.07796253919557863,157.15925543588608,0.3155069297121226,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-540QM,Silfab Solar Inc,Mono-c-Si,0,540.0,511.7,2.3,,,66.0,13.77039618,47.96153014,12.97150951,41.63209589,0.0044065267776,-0.11606690293880001,44.6,1.6760797635337512,13.776637167088785,5.029247178902126e-12,0.06815646303723683,150.38350271808255,3.6077513852431817,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-540XM,Silfab Solar Inc,Mono-c-Si,1,540.0,505.8,2.3,,,66.0,13.78,47.95,12.97,41.62,0.00689,-0.12562900000000002,48.7,1.716704581416209,13.785566357028467,9.972680866097791e-12,0.06082157208061332,150.56908134570355,0.9067188589019576,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-560XM+,Silfab Solar Inc,Mono-c-Si,1,560.0,517.4,2.51,,,72.0,13.73,51.8,12.96,43.21,0.00660413,-0.15006460000000002,49.3,1.9159964083926488,13.74071732271638,2.4563329054916155e-11,0.20318147211987245,260.29650288948505,-1.8408961516879498,-0.3374,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-565XM+,Silfab Solar Inc,Mono-c-Si,1,565.0,522.2,2.51,,,72.0,13.76,51.92,13.0,43.47,0.00661856,-0.15041224,49.3,1.923247036433588,13.76945171770644,2.5627703413716075e-11,0.18915094094407744,275.3697684102419,-1.522342228661984,-0.3374,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-570XM+,Silfab Solar Inc,Mono-c-Si,1,570.0,526.9,2.51,,,72.0,13.79,52.03,13.03,43.74,0.006632989999999999,-0.15073091,49.3,1.9312668826288968,13.798800703570398,2.7133482189618403e-11,0.1734659065215356,271.8072324251594,-1.082047689043165,-0.3374,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-575XM+,Silfab Solar Inc,Mono-c-Si,1,575.0,531.7,2.51,,,72.0,13.82,52.15,13.07,44.0,0.00664742,-0.15107855,49.3,1.938488276245307,13.827653778096453,2.827882684195164e-11,0.15962254170412069,288.2215166561656,-0.7698388511430294,-0.3374,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-580XM+,Silfab Solar Inc,Mono-c-Si,1,580.0,536.5,2.51,,,72.0,13.85,52.27,13.1,44.27,0.00666185,-0.15142619000000002,49.3,1.9466655315959256,13.857042265442479,2.982791170717856e-11,0.1448776884252643,284.9304696561696,-0.35685699722574227,-0.3374,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-585XM+,Silfab Solar Inc,Mono-c-Si,1,585.0,541.3,2.51,,,72.0,13.88,52.39,13.14,44.53,0.00667628,-0.15177383000000003,49.3,1.9538587866895563,13.886012226404423,3.1055131205508365e-11,0.13121486930505047,302.92645205479874,-0.05080241173084144,-0.3374,N,2025.7.3,6/23/2025,4.0,first_pass +Silfab Solar Inc SIL-620XL,Silfab Solar Inc,Mono-c-Si,1,620.0,585.7,2.79,,,78.0,13.55,57.21,12.87,48.16,0.09037850000000001,-0.1550391,43.1,2.666897545857673,13.601817673683652,6.563817475984705e-09,0.09759261296551636,999999.7131105945,60.8830839650474,-0.3308,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-625XL,Silfab Solar Inc,Mono-c-Si,1,625.0,590.5,2.79,,,78.0,13.6,57.35,12.94,48.32,0.09071200000000001,-0.15541850000000001,43.1,2.6736521782425657,13.674461876735853,6.6109773774513384e-09,0.09363820943589155,999999.9637412279,60.91887127081315,-0.3308,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-630XL,Silfab Solar Inc,Mono-c-Si,1,630.0,595.3,2.79,,,78.0,13.66,57.49,13.0,48.47,0.0911122,-0.15579790000000004,43.1,2.6806289065610054,13.736919758747852,6.665126708605088e-09,0.09061669841410631,999999.9725838724,60.97362979637239,-0.3308,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-635XL,Silfab Solar Inc,Mono-c-Si,1,635.0,600.2,2.79,,,78.0,13.71,57.62,13.06,48.62,0.0914457,-0.1561502,43.1,2.687087244675103,13.799086119829326,6.716523572515052e-09,0.08689729070327241,999999.990338442,61.0254599773354,-0.3308,N,2025.7.3,6/23/2025,2.0,first_pass +Silfab Solar Inc SIL-640XL,Silfab Solar Inc,Mono-c-Si,1,640.0,605.0,2.79,,,78.0,13.76,57.76,13.12,48.78,0.0917792,-0.15652960000000002,43.1,2.694036256246036,13.861206120694192,6.769360753693831e-09,0.08309106499125549,999999.9904050858,61.079908892798436,-0.3308,N,2025.7.3,6/23/2025,2.0,first_pass +Sinotec USA LLC STS-310M3-60,Sinotec USA LLC,Mono-c-Si,0,310.0,283.6,1.65,,,60.0,10.04,40.3,9.52,32.6,0.000502,-0.106795,46.8,1.4938020856129601,10.043976207297558,1.920307282497295e-11,0.3328777808711927,840.5228420048649,8.485703230769511,-0.396,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-310M3B-60,Sinotec USA LLC,Mono-c-Si,0,310.0,283.4,1.65,,,60.0,10.04,40.3,9.52,32.6,0.0006023999999999999,-0.09913799999999999,48.2,1.456547852634718,10.045263505257461,9.619389902492167e-12,0.3413340244226825,651.0858188772779,10.533335857975217,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-315M3-60,Sinotec USA LLC,Mono-c-Si,0,315.0,288.3,1.65,,,60.0,10.11,40.5,9.58,32.9,0.0005055,-0.10732500000000002,46.8,1.5048601598188007,10.114849491375015,2.0617109776335388e-11,0.31557237700889457,657.8910207602639,9.051122249935567,-0.396,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-315M3B-60,Sinotec USA LLC,Mono-c-Si,0,315.0,288.1,1.65,,,60.0,10.11,40.5,9.58,32.9,0.0006066,-0.09963000000000001,48.2,1.4672290752854746,10.11610477366788,1.032544157127581e-11,0.3240897835901242,536.718850027979,11.110565449977084,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-320M3-60,Sinotec USA LLC,Mono-c-Si,0,320.0,293.0,1.65,,,60.0,10.18,40.8,9.65,33.2,0.000509,-0.10812,46.8,1.5170321760772314,10.184545323031672,2.1146390449872163e-11,0.3089785771701409,692.0084442591486,9.211752014827482,-0.396,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-320M3B-60,Sinotec USA LLC,Mono-c-Si,0,320.0,292.8,1.65,,,60.0,10.18,40.8,9.65,33.2,0.0006108,-0.100368,48.2,1.4790681113558322,10.185775653230861,1.05898261320888e-11,0.31751951176394744,559.6507524948945,11.27445245695409,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-325M3-60,Sinotec USA LLC,Mono-c-Si,0,325.0,297.8,1.65,,,60.0,10.25,41.0,9.72,33.5,0.0005125,-0.10865000000000001,46.8,1.5273552553588783,10.254309905772322,2.2402191600557326e-11,0.2920674756575452,694.6072323062264,9.6585693366619,-0.396,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-325M3B-60,Sinotec USA LLC,Mono-c-Si,0,325.0,297.5,1.65,,,60.0,10.25,41.0,9.72,33.5,0.0006150000000000001,-0.10086,48.2,1.4890525036715796,10.2554820433352,1.1216753482256969e-11,0.300648857580789,562.1354332285399,11.730421381743199,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-330M3-60,Sinotec USA LLC,Mono-c-Si,0,330.0,302.5,1.65,,,60.0,10.32,41.3,9.78,33.8,0.000516,-0.109445,46.8,1.540269261433992,10.324974069894827,2.3227172696191327e-11,0.2857295582616002,592.8201783896528,9.921342421265955,-0.396,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-330M3B-60,Sinotec USA LLC,Mono-c-Si,0,330.0,302.3,1.65,,,60.0,10.32,41.3,9.78,33.8,0.0006192,-0.101598,48.2,1.5015946233503739,10.326149677216053,1.1628704605235282e-11,0.29435301063904284,493.964642494697,11.998709334901893,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-335M3-60,Sinotec USA LLC,Mono-c-Si,0,335.0,307.2,1.65,,,60.0,10.39,41.6,9.85,34.1,0.0005195,-0.11024000000000002,46.8,1.5524371512902044,10.394677769503973,2.379014721231755e-11,0.27949001661966993,620.787603918942,10.072008606366705,-0.396,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-335M3B-60,Sinotec USA LLC,Mono-c-Si,0,335.0,307.0,1.65,,,60.0,10.39,41.6,9.85,34.1,0.0006234000000000001,-0.10233600000000001,48.2,1.51342965306408,10.395829243169294,1.1909855750033641e-11,0.2881356687133197,513.570895752311,12.152408377197293,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-375M3-72,Sinotec USA LLC,Mono-c-Si,0,375.0,349.2,1.97,,,72.0,9.99,48.4,9.45,39.7,0.0012987,-0.112288,46.2,1.6765761920128714,9.999936534704837,2.863358036154412e-12,0.36580422619936726,367.77248393796566,6.190604008747291,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-380M3-72,Sinotec USA LLC,Mono-c-Si,0,380.0,354.0,1.97,,,72.0,10.06,48.7,9.51,40.0,0.0013078,-0.11298400000000001,46.2,1.688516747658683,10.070527981704883,2.9581316161218004e-12,0.35906366056823014,343.1028409948424,6.417373708762616,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-385M3-72,Sinotec USA LLC,Mono-c-Si,0,385.0,358.8,1.97,,,72.0,10.12,49.0,9.57,40.3,0.0013155999999999999,-0.11368,46.2,1.6997170229725342,10.130174689907932,3.0171982697267074e-12,0.3527365540102621,350.84056285481677,6.5367904810215585,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-385P-54DD,Sinotec USA LLC,Mono-c-Si,0,385.0,361.1,1.94,,,108.0,13.25,36.6,12.55,30.7,0.000795,-0.090036,42.6,1.2983705100531653,13.25884326025604,7.490231973880137e-12,0.14367337851020812,215.2681494739451,5.940831293748643,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-390M3-72,Sinotec USA LLC,Mono-c-Si,0,390.0,363.6,1.97,,,72.0,10.17,49.3,9.62,40.6,0.0013220999999999999,-0.114376,46.2,1.7109585054014766,10.17987099563444,3.0756920940310617e-12,0.34683141052665933,357.3373531121885,6.660535728717219,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-390P-54DD,Sinotec USA LLC,Mono-c-Si,0,390.0,365.9,1.94,,,108.0,13.34,36.8,12.62,30.9,0.0008003999999999999,-0.090528,42.6,1.337302678851063,13.348679034263041,1.4746281667431566e-11,0.13505818076847034,207.58947201915635,11.85012299755553,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-395M3-72,Sinotec USA LLC,Mono-c-Si,0,395.0,368.3,1.97,,,72.0,10.23,49.6,9.67,40.9,0.0013299,-0.11507200000000002,46.2,1.7229469600454772,10.240454933406516,3.1735291328645138e-12,0.3406605935804751,333.33142773369184,6.887061697476046,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-395P-54DD,Sinotec USA LLC,Mono-c-Si,0,395.0,370.8,1.94,,,108.0,13.43,37.0,12.7,31.1,0.0008058000000000001,-0.09102,42.6,1.3455152554568162,13.438918638826113,1.512674786972767e-11,0.1319636037348725,198.71543648950993,12.02195596235457,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-400P-54DD,Sinotec USA LLC,Mono-c-Si,0,400.0,375.6,1.94,,,108.0,13.54,37.2,12.8,31.3,0.0008124,-0.09151200000000001,42.6,1.3536729776749064,13.549088642757702,1.552003852275411e-11,0.12872433877196998,191.76983861634346,12.18254436811979,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-405P-54DD,Sinotec USA LLC,Mono-c-Si,0,405.0,380.4,1.94,,,108.0,13.66,37.4,12.89,31.4,0.0008196,-0.092004,42.6,1.3151818336204706,13.672740127489876,5.9965562563165114e-12,0.1421703861732495,152.4354822789593,3.8073790424706537,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-410P-54DD,Sinotec USA LLC,Mono-c-Si,0,410.0,385.2,1.94,,,108.0,13.77,37.6,12.98,31.6,0.0008261999999999999,-0.092496,42.6,1.3081066708268054,13.784182891455083,4.440075428293067e-12,0.14161887110732865,137.49607147625522,1.2371522478817014,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-415P-54DD,Sinotec USA LLC,Mono-c-Si,0,415.0,390.0,1.94,,,108.0,13.87,37.8,13.06,31.8,0.0008322,-0.092988,42.6,1.37805212144007,13.882433609442359,1.6648767806413647e-11,0.1277790026146331,142.54066774346998,12.621641140622218,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sinotec USA LLC STS-550P-72BB,Sinotec USA LLC,Mono-c-Si,1,550.0,517.7,1.9,,,72.0,14.0,49.92,13.11,41.96,0.00868,-0.13099008,46.8,1.8636134465348815,14.015787492678673,3.180347626097146e-11,0.16293824622821423,144.49004032148488,10.416564856811242,-0.3312,N,2025.7.3,6/23/2025,4.0,first_pass +SKYCELL USA SKY 680-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,680.0,647.5,3.11,,,66.0,16.98,48.91,16.05,42.44,0.00736932,-0.1134712,45.59,1.6266927007463718,16.988663507914517,1.4551883257536757e-12,0.06973127176777928,136.66946536655317,-4.322002268337751,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 685-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,685.0,652.3,3.11,,,66.0,17.06,48.97,16.09,42.63,0.007404040000000001,-0.11361040000000001,45.59,1.632734040499461,17.068426518714634,1.5707110346947455e-12,0.05954795143162126,120.55845190379523,-3.7330307516140064,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 690-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,690.0,657.2,3.11,,,66.0,17.14,49.04,16.14,42.82,0.00743876,-0.11377280000000001,45.59,1.6385048125389603,17.14773993964527,1.677093944341236e-12,0.05013035070406685,111.0130376450369,-3.2321024122466357,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 695-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,695.0,662.1,3.11,,,66.0,17.22,49.1,16.18,43.02,0.00747348,-0.11391200000000001,45.59,1.6447510895225,17.226756192391985,1.815053255292891e-12,0.03935204837110424,100.29943402032345,-2.615802181891746,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 700-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,700.0,666.9,3.11,,,66.0,17.31,49.17,16.23,43.21,0.007512540000000001,-0.1140744,45.59,1.6509922831336254,17.315647770421396,1.9524558744827463e-12,0.02992096326052328,91.70554681303861,-2.051128730839824,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 705-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,705.0,671.8,3.11,,,66.0,17.39,49.24,16.27,43.4,0.00754726,-0.11423680000000001,45.59,1.657279220824349,17.394230311322783,2.0995543279337305e-12,0.020548754088950866,84.47199423602827,-1.4815358496389623,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 710-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,710.0,676.6,3.11,,,66.0,17.47,49.3,16.34,43.53,0.00758198,-0.114376,45.59,1.6608866154749036,17.47317419744099,2.1689629040702942e-12,0.01511815732134427,83.20660996826594,-1.249391308240505,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 715-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,715.0,681.5,3.11,,,66.0,17.61,50.59,16.81,42.54,0.00764274,-0.11736880000000001,45.59,1.651810641063057,17.617175683506122,8.742700733970773e-13,0.1616690098540874,396.7553868512162,-8.685639171983892,-0.2489,N,2025.7.3,6/23/2025,2.0,first_pass +SKYCELL USA SKY 720-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,720.0,686.4,3.11,,,66.0,17.67,50.74,16.87,42.68,0.007668780000000001,-0.11771680000000002,45.59,1.656834827068069,17.676990806358624,8.79442834036938e-13,0.16067547896729165,406.12421077909477,-8.667104945200517,-0.2489,N,2025.7.3,6/23/2025,4.0,bootstrapping +SKYCELL USA SKY 725-BHDG24-USA,SKYCELL USA,Mono-c-Si,1,725.0,691.2,3.11,,,66.0,17.73,50.88,16.93,42.83,0.007694820000000001,-0.11804160000000001,45.59,1.6618505922613047,17.73679025247874,8.897924197321991e-13,0.15843225537141692,413.6818031050339,-8.60291903280965,-0.2489,N,2025.7.3,6/23/2025,2.0,first_pass +Solar Frame Solutions Inc SFS50S,Solar Frame Solutions Inc,Mono-c-Si,0,50.0,45.7,0.36,,,9.0,10.24,6.1,9.65,5.2,0.0038502400000000004,-0.016097900000000002,44.53,0.24441448130068605,10.243849863836687,1.4622280478276544e-10,0.015074907036948321,40.096756604282795,27.63477272287206,-0.412,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frame Solutions Inc SFS135T,Solar Frame Solutions Inc,Mono-c-Si,0,135.0,124.3,0.82,,,24.0,10.28,16.4,9.72,13.9,0.00410172,-0.043607599999999996,44.51,0.6436264527101767,10.283791133999985,8.733292577473777e-11,0.052598993799131195,142.62689542774845,21.445816939329998,-0.3952,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF130-S,Solar Frontier KK,Thin Film,0,130.0,117.9,1.046888,1.223,0.856,170.0,2.1,106.0,1.64,79.5,0.00021,-0.29680000000000006,50.1,3.9297686957410667,2.1940578050638444,3.2018032984822567e-12,8.875294900287175,198.15601002089497,1.3951401964205732,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF130-S-1500,Solar Frontier KK,Thin Film,0,130.0,117.9,1.046888,1.223,0.856,170.0,2.1,106.0,1.64,79.5,0.00021,-0.29680000000000006,50.1,3.9297686957410667,2.1940578050638444,3.2018032984822567e-12,8.875294900287175,198.15601002089497,1.3951401964205732,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF135-S,Solar Frontier KK,Thin Film,0,135.0,122.5,1.046888,1.223,0.856,170.0,2.1,106.0,1.69,80.0,0.00021,-0.29680000000000006,50.1,3.868126513302627,2.1757475064979253,2.163019990647066e-12,8.44062706350085,234.00528547845897,-1.8194526346442692,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF135-S-1500,Solar Frontier KK,Thin Film,0,135.0,122.5,1.046888,1.223,0.856,170.0,2.1,106.0,1.69,80.0,0.00021,-0.29680000000000006,50.1,3.868126513302627,2.1757475064979253,2.163019990647066e-12,8.44062706350085,234.00528547845897,-1.8194526346442692,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF140-S,Solar Frontier KK,Thin Film,0,140.0,127.1,1.046888,1.223,0.856,170.0,2.1,107.0,1.74,80.5,0.00021,-0.29960000000000003,50.1,3.8298304612164857,2.163464956149441,1.3144755309635791e-12,8.608090211781006,284.8341917041548,-5.776346196013695,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF140-S-1500,Solar Frontier KK,Thin Film,0,140.0,127.1,1.046888,1.223,0.856,170.0,2.1,107.0,1.74,80.5,0.00021,-0.29960000000000003,50.1,3.8298304612164857,2.163464956149441,1.3144755309635791e-12,8.608090211781006,284.8341917041548,-5.776346196013695,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF145-S,Solar Frontier KK,Thin Film,0,145.0,131.2,1.046888,1.223,0.856,170.0,2.2,107.0,1.8,81.0,0.00044000000000000007,-0.3531,51.2,3.9376833976669685,2.268662150063139,2.9128414234045442e-12,7.8470952923259425,251.42832965803325,-15.21287485080553,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF145-S-1500,Solar Frontier KK,Thin Film,0,145.0,131.2,1.046888,1.223,0.856,170.0,2.2,107.0,1.8,81.0,0.00044000000000000007,-0.3531,51.2,3.9376833976669685,2.268662150063139,2.9128414234045442e-12,7.8470952923259425,251.42832965803325,-15.21287485080553,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF150-S,Solar Frontier KK,Thin Film,0,150.0,135.8,1.046888,1.223,0.856,170.0,2.2,108.0,1.85,81.5,0.00044000000000000007,-0.35640000000000005,51.2,3.9035245290933074,2.256944750925649,1.839945940880389e-12,8.009613412739954,309.4429121738048,-18.368983924750374,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF150-S-1500,Solar Frontier KK,Thin Film,0,150.0,135.8,1.046888,1.223,0.856,170.0,2.2,108.0,1.85,81.5,0.00044000000000000007,-0.35640000000000005,51.2,3.9035245290933074,2.256944750925649,1.839945940880389e-12,8.009613412739954,309.4429121738048,-18.368983924750374,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF155-S,Solar Frontier KK,Thin Film,0,155.0,140.5,1.046888,1.223,0.856,170.0,2.2,109.0,1.88,82.5,0.00044000000000000007,-0.3597,51.2,3.9120378989876605,2.248125288620847,1.5429572899270741e-12,7.872766309286106,359.8957309704469,-19.563918291840782,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF155-S-1500,Solar Frontier KK,Thin Film,0,155.0,140.5,1.046888,1.223,0.856,170.0,2.2,109.0,1.88,82.5,0.00044000000000000007,-0.3597,51.2,3.9120378989876605,2.248125288620847,1.5429572899270741e-12,7.872766309286106,359.8957309704469,-19.563918291840782,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF160-S,Solar Frontier KK,Thin Film,0,160.0,144.6,1.046888,1.223,0.856,170.0,2.2,110.0,1.91,84.0,0.00022000000000000003,-0.33,49.3,4.076999372165955,2.2367838588407594,3.8016217829571495e-12,7.271119384072212,434.8772323390641,-4.718046531843421,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF160-S-1500,Solar Frontier KK,Thin Film,0,160.0,144.6,1.046888,1.223,0.856,170.0,2.2,110.0,1.91,84.0,0.00022000000000000003,-0.33,49.3,4.076999372165955,2.2367838588407594,3.8016217829571495e-12,7.271119384072212,434.8772323390641,-4.718046531843421,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF165-S,Solar Frontier KK,Thin Film,0,165.0,149.2,1.046888,1.223,0.856,170.0,2.2,110.0,1.93,85.5,0.00022000000000000003,-0.33,49.3,4.095448961334618,2.2283002182030307,4.33760803048034e-12,6.322052538564453,491.46319461414924,-3.7252374429409705,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF165-S-1500,Solar Frontier KK,Thin Film,0,165.0,149.2,1.046888,1.223,0.856,170.0,2.2,110.0,1.93,85.5,0.00022000000000000003,-0.33,49.3,4.095448961334618,2.2283002182030307,4.33760803048034e-12,6.322052538564453,491.46319461414924,-3.7252374429409705,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF170-S,Solar Frontier KK,Thin Film,0,170.0,153.8,1.046888,1.223,0.856,170.0,2.2,112.0,1.95,87.5,0.00022000000000000003,-0.336,49.3,4.159182333403311,2.2235758936717445,4.095431143569669e-12,6.147765065683755,573.6827367470298,-4.201958636072945,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF170-S-1500,Solar Frontier KK,Thin Film,0,170.0,153.8,1.046888,1.223,0.856,170.0,2.2,112.0,1.95,87.5,0.00022000000000000003,-0.336,49.3,4.159182333403311,2.2235758936717445,4.095431143569669e-12,6.147765065683755,573.6827367470298,-4.201958636072945,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SF175-S,Solar Frontier KK,Thin Film,0,175.0,159.2,1.046888,1.223,0.856,170.0,2.2,114.0,1.96,89.5,0.00022000000000000003,-0.31920000000000004,50.3,4.0735411927382446,2.22210399798787,1.4285241199618717e-12,6.16213158435981,613.3139134642645,-5.7164848271217545,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SFK180-S,Solar Frontier KK,CIGS,0,180.0,166.2,1.18,,,184.0,2.18,120.0,1.95,92.4,0.00010900000000000002,-0.3132,45.77,4.218963059731438,2.203868624383287,9.021156579530796e-13,7.640440734237483,697.8265929854093,-2.431220954704964,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SFK185-S,Solar Frontier KK,CIGS,0,185.0,170.9,1.18,,,184.0,2.19,121.0,1.95,95.0,0.0001095,-0.31581,45.77,4.306574390752926,2.2123113774456393,1.2714134111361909e-12,6.589413200533547,646.7917530853399,0.32126116600459853,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Frontier KK SFK190-S,Solar Frontier KK,CIGS,0,190.0,175.7,1.18,,,184.0,2.21,122.0,1.96,97.1,0.00011050000000000002,-0.31842,45.77,4.3821841768502106,2.231074585414262,1.6478505706247467e-12,5.810118448311313,609.2818215004527,2.401036870695801,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Liberty SLX250P6-36,Solar Liberty,Multi-c-Si,0,250.0,221.3,1.92075,1.95,0.985,72.0,8.11,42.0,7.04,35.5,0.003244,-0.1344,48.5,1.8547913525317545,8.129339083032592,1.0635770750037397e-09,0.11525274046465701,48.33216535008723,26.04140449012919,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Liberty SLX 255 USB,Solar Liberty,Multi-c-Si,0,255.0,226.6,1.6367999999999998,1.65,0.992,60.0,8.85,37.54,8.29,30.78,0.0032744999999999996,-0.12463280000000002,48.9,1.5499395036090653,8.858751112861281,2.6395325666433783e-10,0.2583122222399871,261.23116402194614,7.517736589891661,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,0,395.0,369.0,1.94,,,36.0,13.71,36.9,13.03,30.32,0.005895299999999999,-0.100368,45.1,1.34383059161511,13.714623184895563,1.6212838374836534e-11,0.18705958645356283,554.7229972098844,1.167539901958187,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL400ML-54H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,0,400.0,373.8,1.94,,,36.0,13.78,36.98,13.15,30.42,0.0059254,-0.1005856,45.1,1.3450942512837498,13.780002525562004,1.5827352821418157e-11,0.1832685640057543,999993.8922915135,0.9118585377352919,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL405ML-54H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,0,405.0,378.6,1.94,,,36.0,13.85,37.06,13.27,30.52,0.0059555,-0.10080320000000002,45.1,1.3514663749764813,13.850629551767307,1.7057795617206337e-11,0.17929330846359454,3944.4137979581183,1.488221490261876,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,0,410.0,383.4,1.94,,,36.0,13.92,37.14,13.39,30.62,0.005985599999999999,-0.10102080000000001,45.1,1.3567971690697669,13.920002585751902,1.8012330072997554e-11,0.15575949716654514,838354.7188414478,1.8940815603070613,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL415ML-54H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,0,415.0,388.2,1.94,,,36.0,14.01,37.31,13.48,30.79,0.0060243,-0.10148320000000002,45.1,1.3637180318625683,14.010002545405777,1.838915976715734e-11,0.1523895512341437,838603.5444615461,2.012154714330671,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL535MLBT-72H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,1,535.0,498.2,2.5,,,48.0,13.49,49.42,12.79,41.83,0.007014799999999999,-0.1438122,45.2,1.8972479712702668,13.494291636115802,6.512005401691484e-11,0.13298475185857983,418.0140852905175,5.816116325160512,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,1,540.0,503.0,2.5,,,48.0,13.53,49.72,12.84,42.05,0.0070355999999999995,-0.14468519999999999,45.2,1.9070495822853994,13.533799616322472,6.387594178780448e-11,0.13659858349064202,486.4119765239926,5.621962241029391,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL545MLBT-72H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,1,545.0,507.8,2.5,,,48.0,13.57,50.02,12.89,42.27,0.007056400000000001,-0.14555820000000003,45.2,1.916851322330024,13.573277615562686,6.266963935033657e-11,0.14018434344022423,580.391938092664,5.430158751416478,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL550MLBT-72H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,1,550.0,512.6,2.5,,,48.0,13.61,50.32,12.94,42.49,0.0070772,-0.14643119999999998,45.2,1.9266531900292911,13.612726189886198,6.149967901486315e-11,0.14374235701733434,717.6072339739792,5.2406638991416505,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR LONG PV-TECH(CAMBODIA)COLTD SL555MLBT-72H-VTL,SOLAR LONG PV-TECH(CAMBODIA)COLTD,Mono-c-Si,1,555.0,517.4,2.5,,,48.0,13.65,50.62,12.99,42.71,0.007098,-0.1473042,45.2,1.9364551977097129,13.652145888429635,6.036467187959094e-11,0.1472729425805713,936.8034893100385,5.053437906642593,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Power (SPI) ES300PBFW,Solar Power (SPI),Multi-c-Si,0,300.0,272.1,1.9286159999999999,1.956,0.986,72.0,8.57,45.4,8.09,37.1,0.005990430000000001,-0.147096,45.5,1.8893801813091002,8.572910695743936,3.1268652824977256e-10,0.33503361167163087,986.4442739089318,11.567974708155718,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Power (SPI) ES305PBFW,Solar Power (SPI),Multi-c-Si,0,305.0,276.8,1.9286159999999999,1.956,0.986,72.0,8.61,45.8,8.16,37.4,0.00601839,-0.148392,45.5,1.901338638985166,8.610152994914749,2.9749396993792545e-10,0.3407595254181191,19176.84462694776,11.062246822793043,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Solar Power (SPI) ES310PBFW,Solar Power (SPI),Multi-c-Si,0,310.0,281.4,1.9286159999999999,1.956,0.986,72.0,8.65,46.1,8.21,37.8,0.006046350000000001,-0.14936400000000002,45.5,1.917523378914379,8.657523911683441,3.1356813783659505e-10,0.3190331405310684,999999.9850428562,11.48656944207198,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Solar Power (SPI) ES315PBFW,Solar Power (SPI),Multi-c-Si,0,315.0,286.1,1.9286159999999999,1.956,0.986,72.0,8.7,46.4,8.25,38.2,0.0060812999999999996,-0.150336,45.5,1.9345135564879794,8.700251365751788,3.331181576625471e-10,0.29761115243968633,10300.63426004419,11.990258888021119,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR UTILITIES INC SH355M4H-UHB,SOLAR UTILITIES INC,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.06,40.48,10.61,33.71,0.0054194,-0.10779823999999999,44.8,1.4987579291574804,11.06000205478101,2.0600620927356774e-11,0.18577814230681194,999993.110905529,7.1304385272989865,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR UTILITIES INC SH355M4-UHB,SOLAR UTILITIES INC,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.06,40.48,10.61,33.71,0.0054194,-0.10779823999999999,44.8,1.4987579291574804,11.06000205478101,2.0600620927356774e-11,0.18577814230681194,999993.110905529,7.1304385272989865,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR UTILITIES INC SH360M4H-UHB,SOLAR UTILITIES INC,Mono-c-Si,0,360.0,336.1,1.82,,,60.0,11.15,40.69,10.68,32.99,0.0054635000000000005,-0.10835746999999998,44.8,1.488544329404404,11.150003118048717,1.4984656629050553e-11,0.2796331247740773,999989.5303659611,4.32821882862111,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR UTILITIES INC SH360M4-UHB,SOLAR UTILITIES INC,Mono-c-Si,0,360.0,336.1,1.82,,,60.0,11.15,40.69,10.68,32.99,0.0054635000000000005,-0.10835746999999998,44.8,1.488544329404404,11.150003118048717,1.4984656629050553e-11,0.2796331247740773,999989.5303659611,4.32821882862111,-0.3453,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAR UTILITIES INC SH365M4H-UHB,SOLAR UTILITIES INC,Mono-c-Si,0,365.0,340.9,1.82,,,60.0,11.23,40.81,10.75,33.96,0.005502700000000001,-0.10867703,44.8,1.5090070587823987,11.230003617708219,2.0192892615247142e-11,0.2033334212869249,631194.9720581889,6.824584133238124,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAR UTILITIES INC SH365M4-UHB,SOLAR UTILITIES INC,Mono-c-Si,0,365.0,340.9,1.82,,,60.0,11.23,40.81,10.75,33.96,0.005502700000000001,-0.10867703,44.8,1.5090070587823987,11.230003617708219,2.0192892615247142e-11,0.2033334212869249,631194.9720581889,6.824584133238124,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL320-60MH5,Solar4America Technology Inc,Mono-c-Si,0,320.0,300.3,1.62,,,60.0,10.03,40.4,9.7,33.0,0.0024774099999999998,-0.11732159999999998,42.8,1.4743052100007117,10.030002651796096,1.2602046348430573e-11,0.2439391877059704,922679.8420664956,-4.580110660213019,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A320-60MH5,Solar4America Technology Inc,Mono-c-Si,0,320.0,300.3,1.62,,,60.0,10.03,40.4,9.7,33.0,0.0024774099999999998,-0.11732159999999998,42.8,1.4743052100007117,10.030002651796096,1.2602046348430573e-11,0.2439391877059704,922679.8420664956,-4.580110660213019,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A320-60MH5BW,Solar4America Technology Inc,Mono-c-Si,0,320.0,300.2,1.65,,,60.0,10.03,40.4,9.7,33.0,0.0024774099999999998,-0.11732159999999998,42.8,1.4743052100007117,10.030002651796096,1.2602046348430573e-11,0.2439391877059704,922679.8420664956,-4.580110660213019,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL325-60MH5,Solar4America Technology Inc,Mono-c-Si,0,325.0,305.1,1.62,,,60.0,10.12,40.6,9.79,33.2,0.00249964,-0.1179024,42.8,1.4824871203743506,10.120002605212592,1.2924448538703718e-11,0.23749030318470496,922554.0901889685,-4.45395910895915,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A325-60MH5,Solar4America Technology Inc,Mono-c-Si,0,325.0,305.1,1.62,,,60.0,10.12,40.6,9.79,33.2,0.00249964,-0.1179024,42.8,1.4824871203743506,10.120002605212592,1.2924448538703718e-11,0.23749030318470496,922554.0901889685,-4.45395910895915,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A325-60MH5BW,Solar4America Technology Inc,Mono-c-Si,0,325.0,305.0,1.65,,,60.0,10.12,40.6,9.79,33.2,0.00249964,-0.1179024,42.8,1.4824871203743506,10.120002605212592,1.2924448538703718e-11,0.23749030318470496,922554.0901889685,-4.45395910895915,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL330-60MH5,Solar4America Technology Inc,Mono-c-Si,0,330.0,309.9,1.62,,,60.0,10.22,40.8,9.88,33.4,0.0025243400000000004,-0.11848319999999998,42.8,1.4900569518248477,10.220002614899895,1.3116354429027968e-11,0.23572378540119499,921314.4878888984,-4.416024995928125,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A330-60MH5,Solar4America Technology Inc,Mono-c-Si,0,330.0,309.9,1.62,,,60.0,10.22,40.8,9.88,33.4,0.0025243400000000004,-0.11848319999999998,42.8,1.4900569518248477,10.220002614899895,1.3116354429027968e-11,0.23572378540119499,921314.4878888984,-4.416024995928125,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A330-60MH5BB,Solar4America Technology Inc,Mono-c-Si,0,330.0,309.9,1.62,,,60.0,10.22,40.8,9.88,33.4,0.0025243400000000004,-0.11848319999999998,42.8,1.4900569518248477,10.220002614899895,1.3116354429027968e-11,0.23572378540119499,921314.4878888984,-4.416024995928125,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A330-60MH5BW,Solar4America Technology Inc,Mono-c-Si,0,330.0,309.8,1.65,,,60.0,10.22,40.8,9.88,33.4,0.0025243400000000004,-0.11848319999999998,42.8,1.4900569518248477,10.220002614899895,1.3116354429027968e-11,0.23572378540119499,921314.4878888984,-4.416024995928125,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL335-60MH5,Solar4America Technology Inc,Mono-c-Si,0,335.0,314.7,1.62,,,60.0,10.3,41.0,9.97,33.6,0.0025441,-0.119064,42.8,1.4988478851870168,10.300002512088845,1.3582977772878594e-11,0.224934350335641,922287.9815753425,-4.205779009616261,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A335-60MH5,Solar4America Technology Inc,Mono-c-Si,0,335.0,314.7,1.62,,,60.0,10.3,41.0,9.97,33.6,0.0025441,-0.119064,42.8,1.4988478851870168,10.300002512088845,1.3582977772878594e-11,0.224934350335641,922287.9815753425,-4.205779009616261,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A335-60MH5BW,Solar4America Technology Inc,Mono-c-Si,0,335.0,314.6,1.65,,,60.0,10.3,41.0,9.97,33.6,0.0025441,-0.119064,42.8,1.4988478851870168,10.300002512088845,1.3582977772878594e-11,0.224934350335641,922287.9815753425,-4.205779009616261,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL340-60MH5,Solar4America Technology Inc,Mono-c-Si,0,340.0,319.5,1.62,,,60.0,10.39,41.2,10.06,33.8,0.00256633,-0.11964480000000001,42.8,1.5070267892329328,10.390002465543233,1.391910794697942e-11,0.21882112747441398,922148.1050008765,-4.08370346781839,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A340-60MH5,Solar4America Technology Inc,Mono-c-Si,0,340.0,319.5,1.62,,,60.0,10.39,41.2,10.06,33.8,0.00256633,-0.11964480000000001,42.8,1.5070267892329328,10.390002465543233,1.391910794697942e-11,0.21882112747441398,922148.1050008765,-4.08370346781839,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A340-60MH5BW,Solar4America Technology Inc,Mono-c-Si,0,340.0,319.4,1.65,,,60.0,10.39,41.2,10.06,33.8,0.00256633,-0.11964480000000001,42.8,1.5070267892329328,10.390002465543233,1.391910794697942e-11,0.21882112747441398,922148.1050008765,-4.08370346781839,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL345-60MH5,Solar4America Technology Inc,Mono-c-Si,0,345.0,324.4,1.62,,,60.0,10.47,41.4,10.15,34.0,0.0025860900000000005,-0.12022559999999999,42.8,1.5158114390990076,10.47000236114998,1.4402860927744173e-11,0.20815370619981158,923029.599947091,-3.8779722222642397,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A345-60MH5,Solar4America Technology Inc,Mono-c-Si,0,345.0,324.4,1.62,,,60.0,10.47,41.4,10.15,34.0,0.0025860900000000005,-0.12022559999999999,42.8,1.5158114390990076,10.47000236114998,1.4402860927744173e-11,0.20815370619981158,923029.599947091,-3.8779722222642397,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A345-60MH5BW,Solar4America Technology Inc,Mono-c-Si,0,345.0,324.2,1.65,,,60.0,10.47,41.4,10.15,34.0,0.0025860900000000005,-0.12022559999999999,42.8,1.5158114390990076,10.47000236114998,1.4402860927744173e-11,0.20815370619981158,923029.599947091,-3.8779722222642397,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL375-72MH5,Solar4America Technology Inc,Multi-c-Si,0,375.0,351.7,1.94,,,72.0,10.07,47.8,9.48,39.6,0.00248729,-0.1388112,42.8,1.757099190799579,10.080699889280881,1.518332261764643e-11,0.2901337444571375,273.053930520618,-3.1033402306773894,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL375-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,375.0,351.7,1.94,,,72.0,10.07,47.8,9.48,39.6,0.00248729,-0.1388112,42.8,1.757099190799579,10.080699889280881,1.518332261764643e-11,0.2901337444571375,273.053930520618,-3.1033402306773894,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A375-72MH5,Solar4America Technology Inc,Multi-c-Si,0,375.0,351.7,1.94,,,72.0,10.07,47.8,9.48,39.6,0.00248729,-0.1388112,42.8,1.757099190799579,10.080699889280881,1.518332261764643e-11,0.2901337444571375,273.053930520618,-3.1033402306773894,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A375-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,375.0,351.7,1.94,,,72.0,10.07,47.8,9.48,39.6,0.00248729,-0.1388112,42.8,1.757099190799579,10.080699889280881,1.518332261764643e-11,0.2901337444571375,273.053930520618,-3.1033402306773894,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A375-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,375.0,351.6,1.97,,,72.0,10.07,47.8,9.48,39.6,0.00248729,-0.1388112,42.8,1.757099190799579,10.080699889280881,1.518332261764643e-11,0.2901337444571375,273.053930520618,-3.1033402306773894,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL380-72MH5,Solar4America Technology Inc,Multi-c-Si,0,380.0,356.5,1.94,,,72.0,10.15,48.0,9.56,39.8,0.0025070500000000003,-0.139392,42.8,1.7648068705831663,10.16030725627628,1.5395687464218608e-11,0.2849607841172056,280.6131815463952,-3.058246563253226,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL380-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,380.0,356.5,1.94,,,72.0,10.15,48.0,9.56,39.8,0.0025070500000000003,-0.139392,42.8,1.7648068705831663,10.16030725627628,1.5395687464218608e-11,0.2849607841172056,280.6131815463952,-3.058246563253226,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A380-72MH5,Solar4America Technology Inc,Multi-c-Si,0,380.0,356.5,1.94,,,72.0,10.15,48.0,9.56,39.8,0.0025070500000000003,-0.139392,42.8,1.7648068705831663,10.16030725627628,1.5395687464218608e-11,0.2849607841172056,280.6131815463952,-3.058246563253226,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A380-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,380.0,356.5,1.94,,,72.0,10.15,48.0,9.56,39.8,0.0025070500000000003,-0.139392,42.8,1.7648068705831663,10.16030725627628,1.5395687464218608e-11,0.2849607841172056,280.6131815463952,-3.058246563253226,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A380-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,380.0,356.4,1.97,,,72.0,10.15,48.0,9.56,39.8,0.0025070500000000003,-0.139392,42.8,1.7648068705831663,10.16030725627628,1.5395687464218608e-11,0.2849607841172056,280.6131815463952,-3.058246563253226,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL385-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.95,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL385-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.95,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL385-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.95,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL385-72MH5,Solar4America Technology Inc,Multi-c-Si,0,385.0,361.3,1.94,,,72.0,10.22,48.2,9.64,40.0,0.0025243400000000004,-0.1399728,42.8,1.7716737068974997,10.229186575995348,1.5411648997644697e-11,0.2802292171499906,311.75299916832046,-3.109733759510521,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL385-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,385.0,361.3,1.94,,,72.0,10.22,48.2,9.64,40.0,0.0025243400000000004,-0.1399728,42.8,1.7716737068974997,10.229186575995348,1.5411648997644697e-11,0.2802292171499906,311.75299916832046,-3.109733759510521,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.95,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.95,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-108MH10SB,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.94,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,385.0,362.7,1.95,,,54.0,13.53,36.25,12.65,30.45,0.00588555,-0.0905525,43.0,1.3265204974634475,13.547902561861617,1.7854877054985396e-11,0.12892670545133583,97.43735810152499,11.285072396109516,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-72MH5,Solar4America Technology Inc,Multi-c-Si,0,385.0,361.3,1.94,,,72.0,10.22,48.2,9.64,40.0,0.0025243400000000004,-0.1399728,42.8,1.7716737068974997,10.229186575995348,1.5411648997644697e-11,0.2802292171499906,311.75299916832046,-3.109733759510521,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,385.0,361.3,1.94,,,72.0,10.22,48.2,9.64,40.0,0.0025243400000000004,-0.1399728,42.8,1.7716737068974997,10.229186575995348,1.5411648997644697e-11,0.2802292171499906,311.75299916832046,-3.109733759510521,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A385-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,385.0,361.2,1.97,,,72.0,10.22,48.2,9.64,40.0,0.0025243400000000004,-0.1399728,42.8,1.7716737068974997,10.229186575995348,1.5411648997644697e-11,0.2802292171499906,311.75299916832046,-3.109733759510521,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL390-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.5,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL390-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.5,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL390-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.5,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL390-72MH5,Solar4America Technology Inc,Multi-c-Si,0,390.0,366.1,1.94,,,72.0,10.3,48.4,9.72,40.2,0.0025441,-0.1405536,42.8,1.7793885228902615,10.30882328866645,1.56261357712118e-11,0.2752210024788709,321.2833813295074,-3.064196838741816,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL390-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,390.0,366.1,1.94,,,72.0,10.3,48.4,9.72,40.2,0.0025441,-0.1405536,42.8,1.7793885228902615,10.30882328866645,1.56261357712118e-11,0.2752210024788709,321.2833813295074,-3.064196838741816,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.5,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.5,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-108MH10SB,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.6,1.94,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,390.0,367.5,1.95,,,54.0,13.61,36.5,12.73,30.65,0.00592035,-0.091177,43.0,1.335185754540423,13.627800371372494,1.7792808541249823e-11,0.12998758910597388,99.38733763383108,11.198295072778038,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-72MH5,Solar4America Technology Inc,Multi-c-Si,0,390.0,366.1,1.94,,,72.0,10.3,48.4,9.72,40.2,0.0025441,-0.1405536,42.8,1.7793885228902615,10.30882328866645,1.56261357712118e-11,0.2752210024788709,321.2833813295074,-3.064196838741816,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,390.0,366.1,1.94,,,72.0,10.3,48.4,9.72,40.2,0.0025441,-0.1405536,42.8,1.7793885228902615,10.30882328866645,1.56261357712118e-11,0.2752210024788709,321.2833813295074,-3.064196838741816,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A390-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,390.0,366.0,1.97,,,72.0,10.3,48.4,9.72,40.2,0.0025441,-0.1405536,42.8,1.7793885228902615,10.30882328866645,1.56261357712118e-11,0.2752210024788709,321.2833813295074,-3.064196838741816,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL395-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.3,1.95,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL395-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.3,1.95,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL395-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.3,1.95,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL395-72MH5,Solar4America Technology Inc,Multi-c-Si,0,395.0,371.0,1.94,,,72.0,10.37,48.6,9.78,40.4,0.00256139,-0.14113440000000002,42.8,1.78804428449563,10.379250460974317,1.6034304785742746e-11,0.2704559591971893,303.1879516889344,-2.912255921328983,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL395-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,395.0,371.0,1.94,,,72.0,10.37,48.6,9.78,40.4,0.00256139,-0.14113440000000002,42.8,1.78804428449563,10.379250460974317,1.6034304785742746e-11,0.2704559591971893,303.1879516889344,-2.912255921328983,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.3,1.95,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.3,1.95,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-108MH10SB,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.4,1.94,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,395.0,372.3,1.95,,,54.0,13.69,36.75,12.81,30.85,0.005955149999999999,-0.0918015,43.0,1.3438511226898793,13.707692669240409,1.7732535669117948e-11,0.1310351725729506,101.39066604777939,11.112719740568409,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-72MH5,Solar4America Technology Inc,Multi-c-Si,0,395.0,371.0,1.94,,,72.0,10.37,48.6,9.78,40.4,0.00256139,-0.14113440000000002,42.8,1.78804428449563,10.379250460974317,1.6034304785742746e-11,0.2704559591971893,303.1879516889344,-2.912255921328983,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,395.0,371.0,1.94,,,72.0,10.37,48.6,9.78,40.4,0.00256139,-0.14113440000000002,42.8,1.78804428449563,10.379250460974317,1.6034304785742746e-11,0.2704559591971893,303.1879516889344,-2.912255921328983,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A395-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,395.0,370.8,1.97,,,72.0,10.37,48.6,9.78,40.4,0.00256139,-0.14113440000000002,42.8,1.78804428449563,10.379250460974317,1.6034304785742746e-11,0.2704559591971893,303.1879516889344,-2.912255921328983,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL400-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.95,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL400-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.95,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL400-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.95,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL400-72MH5,Solar4America Technology Inc,Multi-c-Si,0,400.0,375.8,1.94,,,72.0,10.47,48.7,9.89,40.5,0.0025860900000000005,-0.14142480000000002,42.8,1.7907196816693158,10.478127574663556,1.597326277312331e-11,0.26660731050752595,343.4454529367686,-3.0239093679865277,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL400-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,400.0,375.8,1.94,,,72.0,10.47,48.7,9.89,40.5,0.0025860900000000005,-0.14142480000000002,42.8,1.7907196816693158,10.478127574663556,1.597326277312331e-11,0.26660731050752595,343.4454529367686,-3.0239093679865277,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.95,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.95,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-108MH10SB,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.94,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,400.0,377.2,1.95,,,54.0,13.78,37.0,12.89,31.05,0.0059943,-0.092426,43.0,1.3529931574691005,13.798177044460525,1.7842840361882488e-11,0.13191535904484378,100.00490769297018,11.110917648979257,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-72MH5,Solar4America Technology Inc,Multi-c-Si,0,400.0,375.8,1.94,,,72.0,10.47,48.7,9.89,40.5,0.0025860900000000005,-0.14142480000000002,42.8,1.7907196816693158,10.478127574663556,1.597326277312331e-11,0.26660731050752595,343.4454529367686,-3.0239093679865277,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,400.0,375.8,1.94,,,72.0,10.47,48.7,9.89,40.5,0.0025860900000000005,-0.14142480000000002,42.8,1.7907196816693158,10.478127574663556,1.597326277312331e-11,0.26660731050752595,343.4454529367686,-3.0239093679865277,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A400-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,400.0,375.6,1.97,,,72.0,10.47,48.7,9.89,40.5,0.0025860900000000005,-0.14142480000000002,42.8,1.7907196816693158,10.478127574663556,1.597326277312331e-11,0.26660731050752595,343.4454529367686,-3.0239093679865277,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL405-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.95,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL405-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.95,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL405-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.95,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL405-72MH5,Solar4America Technology Inc,Multi-c-Si,0,405.0,380.6,1.94,,,72.0,10.54,48.9,9.96,40.7,0.0026033799999999998,-0.14200559999999998,42.8,1.7984905329954668,10.547821190567623,1.6187823912443745e-11,0.26207511161757413,353.1779047457646,-2.9728867513938373,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL405-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,405.0,380.6,1.94,,,72.0,10.54,48.9,9.96,40.7,0.0026033799999999998,-0.14200559999999998,42.8,1.7984905329954668,10.547821190567623,1.6187823912443745e-11,0.26207511161757413,353.1779047457646,-2.9728867513938373,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.95,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.95,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-108MH10SB,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.94,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,405.0,382.0,1.95,,,54.0,13.86,37.25,12.97,31.24,0.0060291,-0.0930505,43.0,1.361441096999535,13.878168825482481,1.7707357854151155e-11,0.13382194368089761,102.0854180790595,10.987800554827535,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-72MH5,Solar4America Technology Inc,Multi-c-Si,0,405.0,380.6,1.94,,,72.0,10.54,48.9,9.96,40.7,0.0026033799999999998,-0.14200559999999998,42.8,1.7984905329954668,10.547821190567623,1.6187823912443745e-11,0.26207511161757413,353.1779047457646,-2.9728867513938373,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,405.0,380.6,1.94,,,72.0,10.54,48.9,9.96,40.7,0.0026033799999999998,-0.14200559999999998,42.8,1.7984905329954668,10.547821190567623,1.6187823912443745e-11,0.26207511161757413,353.1779047457646,-2.9728867513938373,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A405-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,405.0,380.4,1.97,,,72.0,10.54,48.9,9.96,40.7,0.0026033799999999998,-0.14200559999999998,42.8,1.7984905329954668,10.547821190567623,1.6187823912443745e-11,0.26207511161757413,353.1779047457646,-2.9728867513938373,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL410-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.8,1.95,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL410-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.8,1.95,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL410-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.8,1.95,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL410-72MH5,Solar4America Technology Inc,Multi-c-Si,0,410.0,385.4,1.94,,,72.0,10.61,49.1,10.03,40.9,0.00262067,-0.1425864,42.8,1.806262312405536,10.617521880200778,1.640379577052096e-11,0.25760622517838777,363.36687068551987,-2.922180780676304,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL410-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,410.0,385.4,1.94,,,72.0,10.61,49.1,10.03,40.9,0.00262067,-0.1425864,42.8,1.806262312405536,10.617521880200778,1.640379577052096e-11,0.25760622517838777,363.36687068551987,-2.922180780676304,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-108MH10BB,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.8,1.95,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-108MH10BW,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.8,1.95,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-108MH10SB,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.9,1.94,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-108MH10SW,Solar4America Technology Inc,Mono-c-Si,0,410.0,386.8,1.95,,,54.0,13.94,37.5,13.05,31.43,0.0060639,-0.093675,43.0,1.3698896731153718,13.958150023302482,1.757544968580121e-11,0.13570504600737632,104.22734072524219,10.866437558999847,-0.3321,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-72MH5,Solar4America Technology Inc,Multi-c-Si,0,410.0,385.4,1.94,,,72.0,10.61,49.1,10.03,40.9,0.00262067,-0.1425864,42.8,1.806262312405536,10.617521880200778,1.640379577052096e-11,0.25760622517838777,363.36687068551987,-2.922180780676304,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,410.0,385.4,1.94,,,72.0,10.61,49.1,10.03,40.9,0.00262067,-0.1425864,42.8,1.806262312405536,10.617521880200778,1.640379577052096e-11,0.25760622517838777,363.36687068551987,-2.922180780676304,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A410-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,410.0,385.2,1.97,,,72.0,10.61,49.1,10.03,40.9,0.00262067,-0.1425864,42.8,1.806262312405536,10.617521880200778,1.640379577052096e-11,0.25760622517838777,363.36687068551987,-2.922180780676304,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL415-72MH5,Solar4America Technology Inc,Multi-c-Si,0,415.0,390.2,1.94,,,72.0,10.68,49.3,10.11,41.1,0.00263796,-0.1431672,42.8,1.8131632168015492,10.686520905215803,1.6424449412261026e-11,0.25330034280990504,414.8576916101657,-2.969362563585862,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL415-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,415.0,390.2,1.94,,,72.0,10.68,49.3,10.11,41.1,0.00263796,-0.1431672,42.8,1.8131632168015492,10.686520905215803,1.6424449412261026e-11,0.25330034280990504,414.8576916101657,-2.969362563585862,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A415-72MH5,Solar4America Technology Inc,Multi-c-Si,0,415.0,390.2,1.94,,,72.0,10.68,49.3,10.11,41.1,0.00263796,-0.1431672,42.8,1.8131632168015492,10.686520905215803,1.6424449412261026e-11,0.25330034280990504,414.8576916101657,-2.969362563585862,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A415-72MH5BB,Solar4America Technology Inc,Multi-c-Si,0,415.0,390.2,1.94,,,72.0,10.68,49.3,10.11,41.1,0.00263796,-0.1431672,42.8,1.8131632168015492,10.686520905215803,1.6424449412261026e-11,0.25330034280990504,414.8576916101657,-2.969362563585862,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A415-72MH5BW,Solar4America Technology Inc,Mono-c-Si,0,415.0,390.1,1.97,,,72.0,10.68,49.3,10.11,41.1,0.00263796,-0.1431672,42.8,1.8131632168015492,10.686520905215803,1.6424449412261026e-11,0.25330034280990504,414.8576916101657,-2.969362563585862,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A425-108TH10BB,Solar4America Technology Inc,Mono-c-Si,0,425.0,404.3,1.89,,,54.0,14.19,37.87,13.42,31.66,0.005973989999999999,-0.08702526,43.1,1.3052483014723777,14.202866592005797,3.507826431847146e-12,0.15392437387507393,169.75644108501558,5.503790732786067,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A425-108TH10BTT,Solar4America Technology Inc,Mono-c-Si,0,425.0,404.3,1.89,,,54.0,14.19,37.87,13.42,31.66,0.005973989999999999,-0.08702526,43.1,1.3052483014723777,14.202866592005797,3.507826431847146e-12,0.15392437387507393,169.75644108501558,5.503790732786067,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A425-108TH16BB,Solar4America Technology Inc,Mono-c-Si,0,425.0,404.3,1.89,,,54.0,14.19,37.87,13.42,31.66,0.005973989999999999,-0.08702526,43.1,1.3052483014723777,14.202866592005797,3.507826431847146e-12,0.15392437387507393,169.75644108501558,5.503790732786067,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A425-108TH16BTT,Solar4America Technology Inc,Mono-c-Si,0,425.0,404.3,1.89,,,54.0,14.19,37.87,13.42,31.66,0.005973989999999999,-0.08702526,43.1,1.3052483014723777,14.202866592005797,3.507826431847146e-12,0.15392437387507393,169.75644108501558,5.503790732786067,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A430-108TH10BB,Solar4America Technology Inc,Mono-c-Si,0,430.0,409.1,1.89,,,54.0,14.31,37.96,13.45,31.97,0.00602451,-0.08723208,43.1,1.316544636267049,14.327024712672882,4.2043474728645384e-12,0.1329362987971807,111.73865159763567,7.051766892381785,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A430-108TH10BTT,Solar4America Technology Inc,Mono-c-Si,0,430.0,409.1,1.89,,,54.0,14.31,37.96,13.45,31.97,0.00602451,-0.08723208,43.1,1.316544636267049,14.327024712672882,4.2043474728645384e-12,0.1329362987971807,111.73865159763567,7.051766892381785,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A430-108TH16BB,Solar4America Technology Inc,Mono-c-Si,0,430.0,409.1,1.89,,,54.0,14.31,37.96,13.45,31.97,0.00602451,-0.08723208,43.1,1.316544636267049,14.327024712672882,4.2043474728645384e-12,0.1329362987971807,111.73865159763567,7.051766892381785,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A430-108TH16BTT,Solar4America Technology Inc,Mono-c-Si,0,430.0,409.1,1.89,,,54.0,14.31,37.96,13.45,31.97,0.00602451,-0.08723208,43.1,1.316544636267049,14.327024712672882,4.2043474728645384e-12,0.1329362987971807,111.73865159763567,7.051766892381785,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A435-108TH10BB,Solar4America Technology Inc,Mono-c-Si,0,435.0,414.0,1.89,,,54.0,14.44,38.25,13.48,32.27,0.00607924,-0.0878985,43.1,1.3318691418632729,14.462263172132518,4.716417636538283e-12,0.12760764100764777,82.76692675819866,8.02354935578216,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A435-108TH10BTT,Solar4America Technology Inc,Mono-c-Si,0,435.0,414.0,1.89,,,54.0,14.44,38.25,13.48,32.27,0.00607924,-0.0878985,43.1,1.3318691418632729,14.462263172132518,4.716417636538283e-12,0.12760764100764777,82.76692675819866,8.02354935578216,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A435-108TH16BB,Solar4America Technology Inc,Mono-c-Si,0,435.0,414.0,1.89,,,54.0,14.44,38.25,13.48,32.27,0.00607924,-0.0878985,43.1,1.3318691418632729,14.462263172132518,4.716417636538283e-12,0.12760764100764777,82.76692675819866,8.02354935578216,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A435-108TH16BTT,Solar4America Technology Inc,Mono-c-Si,0,435.0,414.0,1.89,,,54.0,14.44,38.25,13.48,32.27,0.00607924,-0.0878985,43.1,1.3318691418632729,14.462263172132518,4.716417636538283e-12,0.12760764100764777,82.76692675819866,8.02354935578216,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A440-108TH10BB,Solar4America Technology Inc,Mono-c-Si,0,440.0,418.8,1.89,,,54.0,14.49,38.57,13.58,32.41,0.0061002899999999995,-0.08863386,43.1,1.3380334689457378,14.510532225137803,4.274285890494897e-12,0.13938920175768696,98.36973266425842,7.099866281354488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A440-108TH10BTT,Solar4America Technology Inc,Mono-c-Si,0,440.0,418.8,1.89,,,54.0,14.49,38.57,13.58,32.41,0.0061002899999999995,-0.08863386,43.1,1.3380334689457378,14.510532225137803,4.274285890494897e-12,0.13938920175768696,98.36973266425842,7.099866281354488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A440-108TH16BB,Solar4America Technology Inc,Mono-c-Si,0,440.0,418.8,1.89,,,54.0,14.49,38.57,13.58,32.41,0.0061002899999999995,-0.08863386,43.1,1.3380334689457378,14.510532225137803,4.274285890494897e-12,0.13938920175768696,98.36973266425842,7.099866281354488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A440-108TH16BTT,Solar4America Technology Inc,Mono-c-Si,0,440.0,418.8,1.89,,,54.0,14.49,38.57,13.58,32.41,0.0061002899999999995,-0.08863386,43.1,1.3380334689457378,14.510532225137803,4.274285890494897e-12,0.13938920175768696,98.36973266425842,7.099866281354488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL530-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,530.0,497.8,2.59,,,72.0,13.72,49.32,12.83,41.32,0.0050764,-0.12571668000000003,43.3,1.824885183827776,13.73808673392931,2.4483653104452446e-11,0.17877269212474942,135.611070351294,11.82874350994671,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A530-144MH10BTT,Solar4America Technology Inc,Mono-c-Si,0,530.0,498.1,2.51,,,72.0,13.72,49.32,12.83,41.32,0.0050764,-0.12571668000000003,43.3,1.824885183827776,13.73808673392931,2.4483653104452446e-11,0.17877269212474942,135.611070351294,11.82874350994671,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A530-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,530.0,497.8,2.59,,,72.0,13.72,49.32,12.83,41.32,0.0050764,-0.12571668000000003,43.3,1.824885183827776,13.73808673392931,2.4483653104452446e-11,0.17877269212474942,135.611070351294,11.82874350994671,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL535-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,535.0,502.6,2.59,,,72.0,13.79,49.46,12.9,41.48,0.0051023,-0.12607354,43.3,1.8307023393613622,13.807556801985287,2.4848995317756917e-11,0.17460607186858473,137.14443791534646,11.915594328052975,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A535-144MH10BTT,Solar4America Technology Inc,Mono-c-Si,0,535.0,503.0,2.51,,,72.0,13.79,49.46,12.9,41.48,0.0051023,-0.12607354,43.3,1.8307023393613622,13.807556801985287,2.4848995317756917e-11,0.17460607186858473,137.14443791534646,11.915594328052975,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A535-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,535.0,502.6,2.59,,,72.0,13.79,49.46,12.9,41.48,0.0051023,-0.12607354,43.3,1.8307023393613622,13.807556801985287,2.4848995317756917e-11,0.17460607186858473,137.14443791534646,11.915594328052975,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL540-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,540.0,507.4,2.59,,,72.0,13.86,49.6,12.97,41.64,0.005128199999999999,-0.12643040000000003,43.3,1.8365196941640816,13.87703622023504,2.5217624704462717e-11,0.17048483910942835,138.6997729933651,12.00197323794154,-0.3476,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A540-144MH10BTT,Solar4America Technology Inc,Mono-c-Si,0,540.0,507.8,2.51,,,72.0,13.86,49.6,12.97,41.64,0.005128199999999999,-0.12643040000000003,43.3,1.8365196941640816,13.87703622023504,2.5217624704462717e-11,0.17048483910942835,138.6997729933651,12.00197323794154,-0.3476,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A540-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,540.0,507.4,2.59,,,72.0,13.86,49.6,12.97,41.64,0.005128199999999999,-0.12643040000000003,43.3,1.8365196941640816,13.87703622023504,2.5217624704462717e-11,0.17048483910942835,138.6997729933651,12.00197323794154,-0.3476,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc OPAL545-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,545.0,512.2,2.59,,,72.0,13.93,49.76,13.04,41.8,0.0051541,-0.12683824,43.3,1.8427034095298804,13.946653949654698,2.545042691316113e-11,0.1679549861775135,140.48397021302583,12.038265565093905,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A545-144MH10BTT,Solar4America Technology Inc,Mono-c-Si,0,545.0,512.6,2.51,,,72.0,13.93,49.76,13.04,41.8,0.0051541,-0.12683824,43.3,1.8427034095298804,13.946653949654698,2.545042691316113e-11,0.1679549861775135,140.48397021302583,12.038265565093905,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A545-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,545.0,512.2,2.59,,,72.0,13.93,49.76,13.04,41.8,0.0051541,-0.12683824,43.3,1.8427034095298804,13.946653949654698,2.545042691316113e-11,0.1679549861775135,140.48397021302583,12.038265565093905,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc OPAL550-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,550.0,517.0,2.59,,,72.0,14.0,49.92,13.11,41.96,0.005180000000000001,-0.12724608,43.3,1.8488877726731223,14.016277835610587,2.568422359019764e-11,0.165452126007121,142.2996171025695,12.074402622581934,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A550-144MH10BTT,Solar4America Technology Inc,Mono-c-Si,0,550.0,517.4,2.51,,,72.0,14.0,49.92,13.11,41.96,0.005180000000000001,-0.12724608,43.3,1.8488877726731223,14.016277835610587,2.568422359019764e-11,0.165452126007121,142.2996171025695,12.074402622581934,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A550-144MH10STT,Solar4America Technology Inc,Mono-c-Si,0,550.0,517.0,2.59,,,72.0,14.0,49.92,13.11,41.96,0.005180000000000001,-0.12724608,43.3,1.8488877726731223,14.016277835610587,2.568422359019764e-11,0.165452126007121,142.2996171025695,12.074402622581934,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A565-144TH10BB,Solar4America Technology Inc,Mono-c-Si,0,565.0,537.4,2.51,,,72.0,14.19,50.62,13.39,42.21,0.005973989999999999,-0.11632476,43.1,1.7443342909048638,14.205604398282047,3.478460574879903e-12,0.21491928374361471,195.4387851425873,5.44006271014746,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A565-144TH10STT,Solar4America Technology Inc,Mono-c-Si,0,565.0,537.4,2.51,,,72.0,14.19,50.62,13.39,42.21,0.005973989999999999,-0.11632476,43.1,1.7443342909048638,14.205604398282047,3.478460574879903e-12,0.21491928374361471,195.4387851425873,5.44006271014746,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A565-144TH16BB,Solar4America Technology Inc,Mono-c-Si,0,565.0,537.4,2.51,,,72.0,14.19,50.62,13.39,42.21,0.005973989999999999,-0.11632476,43.1,1.7443342909048638,14.205604398282047,3.478460574879903e-12,0.21491928374361471,195.4387851425873,5.44006271014746,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A565-144TH16STT,Solar4America Technology Inc,Mono-c-Si,0,565.0,537.4,2.51,,,72.0,14.19,50.62,13.39,42.21,0.005973989999999999,-0.11632476,43.1,1.7443342909048638,14.205604398282047,3.478460574879903e-12,0.21491928374361471,195.4387851425873,5.44006271014746,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A570-144TH10BB,Solar4America Technology Inc,Mono-c-Si,0,570.0,542.3,2.51,,,72.0,14.25,50.76,13.43,42.43,0.00599925,-0.11664647999999998,43.1,1.7521235347733537,14.266418398667533,3.662884196816672e-12,0.2058188168030275,178.63606580232084,5.8611498164326745,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A570-144TH10STT,Solar4America Technology Inc,Mono-c-Si,0,570.0,542.3,2.51,,,72.0,14.25,50.76,13.43,42.43,0.00599925,-0.11664647999999998,43.1,1.7521235347733537,14.266418398667533,3.662884196816672e-12,0.2058188168030275,178.63606580232084,5.8611498164326745,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A570-144TH16BB,Solar4America Technology Inc,Mono-c-Si,0,570.0,542.3,2.51,,,72.0,14.25,50.76,13.43,42.43,0.00599925,-0.11664647999999998,43.1,1.7521235347733537,14.266418398667533,3.662884196816672e-12,0.2058188168030275,178.63606580232084,5.8611498164326745,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A570-144TH16STT,Solar4America Technology Inc,Mono-c-Si,0,570.0,542.3,2.51,,,72.0,14.25,50.76,13.43,42.43,0.00599925,-0.11664647999999998,43.1,1.7521235347733537,14.266418398667533,3.662884196816672e-12,0.2058188168030275,178.63606580232084,5.8611498164326745,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A575-144TH10BB,Solar4America Technology Inc,Mono-c-Si,0,575.0,547.2,2.51,,,72.0,14.31,50.98,13.49,42.62,0.00602451,-0.11715204000000001,43.1,1.759633103327865,14.326199209904146,3.674252917364576e-12,0.2053418662242926,181.3941605777738,5.850350193196099,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A575-144TH10STT,Solar4America Technology Inc,Mono-c-Si,0,575.0,547.2,2.51,,,72.0,14.31,50.98,13.49,42.62,0.00602451,-0.11715204000000001,43.1,1.759633103327865,14.326199209904146,3.674252917364576e-12,0.2053418662242926,181.3941605777738,5.850350193196099,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A575-144TH16BB,Solar4America Technology Inc,Mono-c-Si,0,575.0,547.2,2.51,,,72.0,14.31,50.98,13.49,42.62,0.00602451,-0.11715204000000001,43.1,1.759633103327865,14.326199209904146,3.674252917364576e-12,0.2053418662242926,181.3941605777738,5.850350193196099,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A575-144TH16STT,Solar4America Technology Inc,Mono-c-Si,0,575.0,547.2,2.51,,,72.0,14.31,50.98,13.49,42.62,0.00602451,-0.11715204000000001,43.1,1.759633103327865,14.326199209904146,3.674252917364576e-12,0.2053418662242926,181.3941605777738,5.850350193196099,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A580-144TH10BB,Solar4America Technology Inc,Mono-c-Si,0,580.0,552.0,2.51,,,72.0,14.37,51.34,13.55,42.82,0.0060497699999999995,-0.11797932000000003,43.1,1.7699056331279557,14.386520535703596,3.563690293015022e-12,0.21441214006642612,186.5013647956437,5.5447631000874775,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A580-144TH10STT,Solar4America Technology Inc,Mono-c-Si,0,580.0,552.0,2.51,,,72.0,14.37,51.34,13.55,42.82,0.0060497699999999995,-0.11797932000000003,43.1,1.7699056331279557,14.386520535703596,3.563690293015022e-12,0.21441214006642612,186.5013647956437,5.5447631000874775,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A580-144TH16BB,Solar4America Technology Inc,Mono-c-Si,0,580.0,552.0,2.51,,,72.0,14.37,51.34,13.55,42.82,0.0060497699999999995,-0.11797932000000003,43.1,1.7699056331279557,14.386520535703596,3.563690293015022e-12,0.21441214006642612,186.5013647956437,5.5447631000874775,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A580-144TH16STT,Solar4America Technology Inc,Mono-c-Si,0,580.0,552.0,2.51,,,72.0,14.37,51.34,13.55,42.82,0.0060497699999999995,-0.11797932000000003,43.1,1.7699056331279557,14.386520535703596,3.563690293015022e-12,0.21441214006642612,186.5013647956437,5.5447631000874775,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A585-144TH10BB,Solar4America Technology Inc,Mono-c-Si,0,585.0,556.9,2.51,,,72.0,14.44,51.33,13.6,43.03,0.00607924,-0.11795633999999999,43.1,1.7747198855339423,14.45660222075295,3.8889715479806896e-12,0.1950336397782017,169.63307516939196,6.274158748146996,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A585-144TH10STT,Solar4America Technology Inc,Mono-c-Si,0,585.0,556.9,2.51,,,72.0,14.44,51.33,13.6,43.03,0.00607924,-0.11795633999999999,43.1,1.7747198855339423,14.45660222075295,3.8889715479806896e-12,0.1950336397782017,169.63307516939196,6.274158748146996,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A585-144TH16BB,Solar4America Technology Inc,Mono-c-Si,0,585.0,556.9,2.51,,,72.0,14.44,51.33,13.6,43.03,0.00607924,-0.11795633999999999,43.1,1.7747198855339423,14.45660222075295,3.8889715479806896e-12,0.1950336397782017,169.63307516939196,6.274158748146996,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A585-144TH16STT,Solar4America Technology Inc,Mono-c-Si,0,585.0,556.9,2.51,,,72.0,14.44,51.33,13.6,43.03,0.00607924,-0.11795633999999999,43.1,1.7747198855339423,14.45660222075295,3.8889715479806896e-12,0.1950336397782017,169.63307516939196,6.274158748146996,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solar4America Technology Inc S4A590-144TH10BB,Solar4America Technology Inc,Mono-c-Si,0,590.0,561.8,2.51,,,72.0,14.49,51.83,13.65,43.21,0.0061002899999999995,-0.11910534,43.1,1.7872067149231377,14.507776864494458,3.6134432703780038e-12,0.21618598038496115,176.21413831445128,5.597552072927852,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A590-144TH10STT,Solar4America Technology Inc,Mono-c-Si,0,590.0,561.8,2.51,,,72.0,14.49,51.83,13.65,43.21,0.0061002899999999995,-0.11910534,43.1,1.7872067149231377,14.507776864494458,3.6134432703780038e-12,0.21618598038496115,176.21413831445128,5.597552072927852,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A590-144TH16BB,Solar4America Technology Inc,Mono-c-Si,0,590.0,561.8,2.51,,,72.0,14.49,51.83,13.65,43.21,0.0061002899999999995,-0.11910534,43.1,1.7872067149231377,14.507776864494458,3.6134432703780038e-12,0.21618598038496115,176.21413831445128,5.597552072927852,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Solar4America Technology Inc S4A590-144TH16STT,Solar4America Technology Inc,Mono-c-Si,0,590.0,561.8,2.51,,,72.0,14.49,51.83,13.65,43.21,0.0061002899999999995,-0.11910534,43.1,1.7872067149231377,14.507776864494458,3.6134432703780038e-12,0.21618598038496115,176.21413831445128,5.597552072927852,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +Solarbest Energy-Tech (Zhejiang) ZSB-M180(125),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,180.0,161.7,1.2766400000000002,1.58,0.808,72.0,5.49,44.35,4.98,36.14,0.00404613,-0.1772226,45.7,1.9660461967489549,5.507421244720001,8.335189941005248e-10,0.4905568228397363,154.59040836831574,1.4448794948095214,-0.4607,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbest Energy-Tech (Zhejiang) SE-M230(125),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,230.0,206.6,1.6367999999999998,1.65,0.992,60.0,5.46,58.91,4.8,47.96,0.0040240200000000005,-0.23540435999999998,45.7,2.662292104254196,5.489548656451722,1.2270021344882718e-09,0.6473986750190748,119.62632474325792,4.830535270406181,-0.4607,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbest Energy-Tech (Zhejiang) SE-M230(156),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,230.0,206.4,1.6367999999999998,1.65,0.992,60.0,8.63,36.57,7.65,30.08,0.006610580000000001,-0.15867723,45.8,1.6708116695263668,8.663143734946205,2.488906474516381e-09,0.2036992607677987,53.03943170598103,-1.58460992123653,-0.4614,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbest Energy-Tech (Zhejiang) SE-M235(125),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,235.0,211.2,1.6367999999999998,1.65,0.992,60.0,5.47,58.98,4.9,48.0,0.00403139,-0.23568408,45.7,2.632817126019277,5.492709365226361,9.562076853980007e-10,0.6629867633934549,159.69350143994382,2.6518205510460615,-0.4607,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbest Energy-Tech (Zhejiang) SE-M235(156),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,235.0,211.0,1.6367999999999998,1.65,0.992,60.0,8.64,36.72,7.8,30.12,0.00661824,-0.15932807999999998,45.8,1.6546922871155934,8.666215025322357,1.880992781365241e-09,0.22270243642199264,73.39872194005814,-3.8709514272888965,-0.4614,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbest Energy-Tech (Zhejiang) SE-M240(125),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,240.0,215.8,1.6367999999999998,1.65,0.992,60.0,5.49,59.04,4.99,48.09,0.00404613,-0.23592384000000002,45.7,2.613342082306587,5.506742766015896,8.078248042885728e-10,0.6590121702486414,216.09197271307926,1.1804960861104565,-0.4607,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbest Energy-Tech (Zhejiang) SE-M240(156),Solarbest Energy-Tech (Zhejiang),Mono-c-Si,0,240.0,215.6,1.6367999999999998,1.65,0.992,60.0,8.66,37.32,7.87,30.48,0.00663356,-0.16193148000000002,45.8,1.6699447639288523,8.684690493667965,1.625891700407798e-09,0.24770321348191005,86.88000437361207,-5.045731763119918,-0.4614,N,2025.7.3,6/23/2025,4.0,first_pass +Solarbine S6T AC,Solarbine,Mono-c-Si,0,255.0,229.6,1.6632,1.68,0.99,60.0,8.86,37.5,8.32,30.65,0.0094802,-0.14024999999999999,46.1,1.6546480298799044,8.864418852955453,1.262636053060262e-09,0.24414522066546795,489.5225848943043,7.410573439128044,-0.451,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC255,SolarCity Corp,Multi-c-Si,0,255.0,225.2,1.572049,1.619,0.971,60.0,8.83,38.0,8.28,30.8,0.0058189700000000006,-0.133076,49.8,1.617729441497858,8.837002363103776,5.493547901856428e-10,0.2979383712792605,375.70126290982563,7.768801816003633,-0.458,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC260,SolarCity Corp,Multi-c-Si,0,260.0,233.5,1.572049,1.619,0.971,60.0,9.09,38.3,8.39,31.0,-0.0007635599999999999,-0.1328244,46.1,1.5506720116735477,9.113888804896959,1.651142831789556e-10,0.3191816101173963,121.45274570015563,-0.5011913342883754,-0.4708,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC265,SolarCity Corp,Multi-c-Si,0,265.0,238.2,1.572049,1.619,0.971,60.0,9.26,38.3,8.55,31.0,-0.00077784,-0.1328244,46.1,1.5503702757463251,9.284019608675102,1.6746801716493933e-10,0.31334273113942146,120.79937857821211,-0.5373483945449471,-0.4708,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC270,SolarCity Corp,Multi-c-Si,0,270.0,242.8,1.572049,1.619,0.971,60.0,9.43,38.3,8.71,31.0,-0.0007921199999999999,-0.1328244,46.1,1.5500798795642852,9.4541503759539,1.6982575087114122e-10,0.30771342451364775,120.15289993894014,-0.5721474801134632,-0.4708,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC310B2,SolarCity Corp,Mono-c-Si,0,310.0,289.7,1.6,,,96.0,5.78,69.9,5.34,58.1,0.0035836,-0.1828584,49.2,2.4586143554035296,5.795505475935585,2.493012776126914e-12,0.7522487011592978,280.41690007669445,-3.2529274680326927,-0.2775,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC315B1,SolarCity Corp,Mono-c-Si,0,315.0,292.2,1.6,,,96.0,5.83,70.2,5.4,58.4,0.0025477100000000003,-0.1806246,48.9,2.5103874084102515,5.843704364966728,4.025299607068272e-12,0.72060827348364,306.55533838629026,2.507490266249974,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC315B2,SolarCity Corp,Mono-c-Si,0,315.0,294.4,1.6,,,96.0,5.83,70.2,5.4,58.4,0.0036146000000000004,-0.1836432,49.2,2.4671816796372936,5.844337733982889,2.4649393976469788e-12,0.7387448140634182,300.38793261415765,-3.4209747162865054,-0.2775,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC320,SolarCity Corp,Multi-c-Si,0,320.0,301.7,1.67427,1.59,1.053,96.0,5.98,69.4,5.59,57.3,0.001794,-0.17350000000000002,43.8,2.4159667135727756,5.9918250831965505,1.9482809810959023e-12,0.8037879465047058,406.4793324662957,-0.6188086980829459,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC320B1,SolarCity Corp,Mono-c-Si,0,320.0,297.0,1.6,,,96.0,5.89,70.5,5.46,58.7,0.0025739300000000003,-0.18139649999999996,48.9,2.5212107435475595,5.90332047716839,4.074585899382688e-12,0.7059115883844421,312.13741132305046,2.520619718965925,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC320B2,SolarCity Corp,Mono-c-Si,0,320.0,299.2,1.6,,,96.0,5.89,70.5,5.46,58.7,0.0036518,-0.18442799999999998,49.2,2.477828529672942,5.903947335234553,2.495446179535669e-12,0.7239299612575776,305.71771622329686,-3.40724924182567,-0.2775,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC325,SolarCity Corp,Multi-c-Si,0,325.0,306.5,1.67427,1.59,1.053,96.0,6.03,69.6,5.65,57.6,0.001809,-0.174,43.8,2.4230487316702356,6.040422757718824,1.972344832724324e-12,0.772249182393835,446.7783575712328,-0.5960630978378004,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +SolarCity Corp SC330,SolarCity Corp,Multi-c-Si,0,330.0,311.3,1.67427,1.59,1.053,96.0,6.07,69.7,5.7,58.0,0.0018210000000000001,-0.17425000000000002,43.8,2.430483976046009,6.078769935634052,2.0847007529681133e-12,0.7048992887657342,487.8871255441279,-0.20475686004974034,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-355M-120N {Blk},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,355.0,332.0,1.84,,,40.0,11.21,41.0,10.63,33.4,0.0062776,-0.11193000000000002,44.1,1.5182980727406707,11.2148994830223,2.0876136439595914e-11,0.2792945908370562,639.0250648375697,4.407389184059093,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-355M-120N {Wht},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,355.0,330.3,1.84,,,40.0,11.21,41.0,10.63,33.4,0.005605000000000001,-0.11767,45.2,1.5216948553532719,11.214783615948903,2.2175710354506543e-11,0.2786027518672307,652.8820414479171,-0.15606051276065097,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-360M-120N {Blk},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,360.0,336.8,1.84,,,40.0,11.28,41.2,10.71,33.6,0.0063168,-0.11247600000000002,44.1,1.5256566662387507,11.283593880707192,2.1017701134241558e-11,0.2749047401255719,862.8348643893269,4.407191153770994,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-360M-120N {Wht},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,360.0,335.1,1.84,,,40.0,11.28,41.2,10.71,33.6,0.00564,-0.118244,45.2,1.5290687394688989,11.283482145525713,2.2325670816506923e-11,0.2742145851097259,888.285864934075,-0.15644847326918074,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Blk},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,365.0,341.6,1.84,,,40.0,11.36,41.4,10.8,33.8,0.006361599999999999,-0.113022,44.1,1.5329847891760129,11.362281428423941,2.1167587087672562e-11,0.27034151602214546,1346.12148128455,4.402661935393706,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-365M-120N {Wht},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,365.0,339.9,1.84,,,40.0,11.36,41.4,10.8,33.8,0.00568,-0.11881799999999998,45.2,1.5364116060592021,11.362173835322292,2.248430621735756e-11,0.26965377871242185,1409.1528774807136,-0.16103548237613005,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-370M-120N {Blk},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,370.0,346.4,1.84,,,40.0,11.45,41.6,10.88,34.0,0.006411999999999999,-0.11356800000000002,44.1,1.5379931208218407,11.450009590182782,2.0506970221464786e-11,0.26626738124422056,317856.89675830485,4.058737568091178,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-370M-120N {Wht},SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,370.0,344.7,1.84,,,40.0,11.45,41.6,10.88,34.0,0.005725,-0.119392,45.2,1.5450691101740952,11.452796371355374,2.3139451858218717e-11,0.264930594609295,1084.782768976269,0.010101847425136428,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-410M-108,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,410.0,380.0,1.98,,,36.0,13.66,37.05,13.14,31.2,0.0065568,-0.108927,46.99,1.3919117845681308,13.660002924540276,3.7615719749690287e-11,0.11703592200735419,546668.8201323018,0.1060923609903343,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-415M-108,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,415.0,384.8,1.98,,,36.0,13.73,37.25,13.21,31.42,0.006590400000000001,-0.10951499999999999,46.99,1.4005616982770457,13.730002844015369,3.863380020229938e-11,0.11258871323797738,543557.3142124871,0.2810853100551485,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-420M-108,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,420.0,389.5,1.98,,,36.0,13.8,37.45,13.28,31.63,0.0066240000000000005,-0.110103,46.99,1.4090136538410476,13.800002782419412,3.952005702388138e-11,0.10904896207776663,540866.1575442983,0.42388512566978126,-0.349,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-430M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,430.0,400.7,2.19,,,48.0,11.19,49.2,10.6,40.6,0.0068259,-0.13776000000000002,44.8,1.8606367041502048,11.195307229045428,3.646361135220167e-11,0.273870620300121,577.4411285345648,6.4422659099557835,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-435M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,435.0,405.5,2.19,,,48.0,11.26,49.4,10.67,40.8,0.0068686,-0.13832,44.8,1.8687180820113811,11.265027786684588,3.697338069781992e-11,0.2695130845956772,603.5891366605691,6.507178658288414,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-440M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,440.0,410.3,2.19,,,48.0,11.33,49.6,10.74,41.0,0.0069112999999999996,-0.13888000000000003,44.8,1.8768004642425538,11.33475519567252,3.7486836841797146e-11,0.26521250290560966,631.9104319986919,6.571685942760646,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-440M-96-BD,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,440.0,413.9,1.98,,,32.0,15.95,34.67,14.81,29.72,0.0071775,-0.086675,46.0,1.2460836160809468,15.967950894084082,1.2674241316021988e-11,0.06411170452851221,56.96550173829936,6.724293540956307,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-445M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,445.0,415.1,2.19,,,48.0,11.4,49.8,10.8,41.2,0.006954,-0.13944,44.8,1.875544873028144,11.400010713822399,3.352648934107673e-11,0.2627669109835836,279599.5301999363,5.5365715153031365,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-445M-96-BD,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,445.0,418.8,1.98,,,32.0,16.0,34.85,14.89,29.9,0.0072,-0.08712500000000001,46.0,1.2516790522600967,16.016337327371833,1.250158101874109e-11,0.06253570888227376,61.244493715203845,6.567833853106107,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-450M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,450.0,419.9,2.19,,,48.0,11.47,50.0,10.87,41.4,0.006996700000000001,-0.14,44.8,1.8938126274329758,11.47499983939231,3.893906898361363e-11,0.2567025031773198,588.8944756078228,6.795709476157671,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*105-450M-96-BD,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,450.0,423.6,1.98,,,32.0,16.05,35.03,14.97,30.08,0.0072225,-0.087575,46.0,1.2572761865086484,16.064794145793556,1.2333456958790411e-11,0.06097634102443763,66.15253682011664,6.413231478327502,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-450M-120-BH,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,450.0,418.6,2.14,,,40.0,13.59,41.48,13.07,34.43,0.006795,-0.11033680000000001,46.51,1.5279319287632422,13.590004457734741,2.2033054507172706e-11,0.1789076653018213,545434.46433075,6.037728403186983,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-455M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,455.0,424.6,2.19,,,48.0,11.54,50.2,10.93,41.6,0.0070393999999999995,-0.14056000000000002,44.8,1.902742357363366,11.5454932420389,3.988946062103624e-11,0.2524839714593731,530.4090165129389,6.954478467821796,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-455M-120-BH,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,455.0,423.4,2.14,,,40.0,13.66,41.68,13.14,34.63,0.00683,-0.1108688,46.51,1.533327589638824,13.660004436811088,2.1386869419686293e-11,0.1763209402877718,542864.7370819582,5.737555630158143,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-166*83-460M-144N,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,460.0,429.4,2.19,,,48.0,11.61,50.4,11.0,41.8,0.007082099999999999,-0.14112000000000002,44.8,1.9002878940183925,11.610008753823397,3.5183546420518105e-11,0.2503038982924042,331977.2798588917,5.793479705103626,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-460M-120-BH,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,460.0,428.2,2.14,,,40.0,13.73,41.88,13.21,34.82,0.0068650000000000004,-0.11140080000000002,46.51,1.5390656410899999,13.730004432652601,2.0890280314393158e-11,0.17453824673404505,540636.191975959,5.4921381597739565,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-465M-120-BH,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,465.0,433.0,2.14,,,40.0,13.8,42.08,13.28,35.02,0.006900000000000001,-0.11193280000000001,46.51,1.5446831097637548,13.800004408518157,2.0365675680378482e-11,0.17196732273059345,538318.9901685076,5.230872171026733,-0.342,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-545M-144,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,545.0,506.4,2.56,,,48.0,13.59,49.78,13.07,41.7,0.0065232,-0.141873,46.0,1.8819720008776406,13.590989546681753,4.41645158760944e-11,0.17461209464509084,2398.046142263188,4.685655980678215,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-550M-144,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,550.0,511.2,2.56,,,48.0,13.66,49.98,13.14,41.86,0.0065568,-0.142443,46.0,1.877788149454771,13.660004623738029,3.767758199689161e-11,0.17696703075541256,522828.34762488585,3.301495485185863,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +SOLAREVER TECNOLOG A DE AMERICA SA DE CV SE-182*91-555M-144,SOLAREVER TECNOLOG A DE AMERICA SA DE CV,Mono-c-Si,0,555.0,516.0,2.56,,,48.0,13.73,50.18,13.21,42.01,0.006590400000000001,-0.143013,46.0,1.8846819991664967,13.730004690715962,3.754034920913419e-11,0.17832421691863914,521976.42337279115,3.228316255312507,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM265M-60,Solarhome Tech Inc,Mono-c-Si,0,265.0,238.1,1.627,,,60.0,9.05,38.26,8.52,31.11,0.0057377,-0.13547866,46.6,1.6240732223684784,9.054170904651166,5.280668763343149e-10,0.28028422998856134,608.1586313110308,6.036979169559025,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM270M-60,Solarhome Tech Inc,Mono-c-Si,0,270.0,242.7,1.63,,,60.0,9.17,38.46,8.62,31.33,0.00581378,-0.13618686000000002,46.6,1.6356449365472208,9.175351926258957,5.582354015640016e-10,0.2700462956702555,462.69796469339036,6.40745106967331,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM275M-60,Solarhome Tech Inc,Mono-c-Si,0,275.0,247.3,1.63,,,60.0,9.25,38.86,8.73,31.51,0.0058645,-0.13760326,46.6,1.6446646604507658,9.252210512433903,5.049742361245628e-10,0.2906539046126313,1216.2569589378252,5.45743591817908,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM280M-60,Solarhome Tech Inc,Mono-c-Si,0,280.0,252.0,1.63,,,60.0,9.37,39.05,8.84,31.68,0.005940579999999999,-0.13827604999999998,46.6,1.6535159446788723,9.372563454914495,5.17222716102302e-10,0.28617507967076516,1046.0346644090296,5.553483614513898,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM285M-60,Solarhome Tech Inc,Mono-c-Si,0,285.0,256.6,1.63,,,60.0,9.49,39.25,8.95,31.85,0.00601666,-0.13898425,46.6,1.6625393759609615,9.492902408753316,5.277501681602507e-10,0.28295165323405774,925.1671006045988,5.61826229262858,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM290M-60,Solarhome Tech Inc,Mono-c-Si,0,290.0,261.3,1.63,,,60.0,9.56,39.46,9.06,32.07,0.00606104,-0.13972786,46.6,1.6695760636416723,9.571569943015346,5.206468299809413e-10,0.2758931455984716,999999.980550971,5.41819830615019,-0.4567,N,2025.7.3,6/23/2025,2.0,first_pass +Solarhome Tech Inc BSM295M-60,Solarhome Tech Inc,Mono-c-Si,0,295.0,265.9,1.63,,,60.0,9.72,39.64,9.14,32.29,0.0061624800000000006,-0.14036524000000003,46.6,1.6854920325423866,9.725415548141417,5.891784953520707e-10,0.26277773378783686,471.6421109860132,6.369257400821876,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM300M-60,Solarhome Tech Inc,Mono-c-Si,0,300.0,270.6,1.63,,,60.0,9.84,39.82,9.23,32.51,0.00623856,-0.14100262000000002,46.6,1.6976732378803763,9.847334339655337,6.330267661241469e-10,0.25108960745190123,336.8704688223921,6.89268259678697,-0.4567,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM305M-60,Solarhome Tech Inc,Mono-c-Si,0,305.0,280.2,1.63,,,60.0,9.96,40.0,9.32,32.73,0.006513840000000001,-0.13355999999999998,44.9,1.6353177831922803,9.971363206140543,2.333744464340258e-10,0.25632005447654843,224.66792459457955,4.510452338608254,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM310M-60,Solarhome Tech Inc,Mono-c-Si,0,310.0,285.0,1.63,,,60.0,10.08,40.18,9.41,32.95,0.00659232,-0.13416102,44.9,1.6468453238137426,10.093034785905633,2.505044677542328e-10,0.24509686879267495,189.53718312600037,5.017705368365235,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM315M-60,Solarhome Tech Inc,Mono-c-Si,0,315.0,289.7,1.63,,,60.0,10.04,40.7,9.49,33.2,0.00656616,-0.1358973,44.9,1.652229682042404,10.043296347975405,2.0026672387932908e-10,0.2723436780732391,829.5032112026145,3.124195576845302,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM320M-60,Solarhome Tech Inc,Mono-c-Si,0,320.0,294.4,1.63,,,60.0,10.15,40.9,9.59,33.4,0.0066381,-0.1365651,44.9,1.6617427470894528,10.153710815987571,2.065614333508441e-10,0.26618262093778017,728.0755022643596,3.293185921138251,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM365M-72,Solarhome Tech Inc,Mono-c-Si,0,365.0,335.4,1.94,,,72.0,9.93,48.01,9.29,39.29,0.00649422,-0.16030539,44.9,1.9631739824012493,9.941473893410356,2.337253129158977e-10,0.30781768962088724,266.39865188486493,4.549391493921933,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM370M-72,Solarhome Tech Inc,Mono-c-Si,0,370.0,340.1,1.94,,,72.0,10.03,48.23,9.37,39.51,0.00655962,-0.16103996999999998,44.9,1.9748414203618292,10.04258501631383,2.4357287890569736e-10,0.3009627182491128,239.86113294038213,4.819095449211141,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM375M-72,Solarhome Tech Inc,Mono-c-Si,0,375.0,344.9,1.94,,,72.0,10.12,48.45,9.44,39.73,0.0066184799999999995,-0.16177455,44.9,1.986582446622832,10.13369131832345,2.5367677331502575e-10,0.2945056805098349,217.68522279946262,5.093578248105557,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM380M-72,Solarhome Tech Inc,Mono-c-Si,0,380.0,349.6,1.94,,,72.0,10.22,48.67,9.52,39.95,0.0066838800000000005,-0.16250913,44.9,1.9982464493683993,10.234710206733574,2.6411559097050875e-10,0.2878715030890471,200.00038016427231,5.358077615257439,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solarhome Tech Inc BSM385M-72,Solarhome Tech Inc,Mono-c-Si,0,385.0,354.4,1.938,,,72.0,10.31,48.89,9.59,40.17,0.0067427400000000005,-0.16324371,44.9,2.009987489467222,10.325723487214244,2.748289844279505e-10,0.2816105247815675,184.6539915308944,5.627694358199251,-0.4131,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-335R-BD,Solaria Corporation,Mono-c-Si,0,335.0,304.2,1.81,,,360.0,9.32,46.7,8.73,38.4,0.0,-0.1401,47.1,1.799108474147298,9.332275329098158,4.8743151388412086e-11,0.32272169381955274,245.02530351436988,3.987702094322685,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-335R-PD,Solaria Corporation,Mono-c-Si,0,335.0,304.2,1.81,,,360.0,9.4,46.3,8.81,38.0,0.004568399999999999,-0.1430207,47.1,1.871027106939624,9.409823467693807,1.656702258412902e-10,0.3048823711385922,291.73959270713885,10.674630134874445,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-340R-BD,Solaria Corporation,Mono-c-Si,0,340.0,308.8,1.81,,,360.0,9.36,46.9,8.79,38.6,0.0045489599999999995,-0.1448741,47.1,1.896237034638588,9.36811418888216,1.6739761157111184e-10,0.29608948749911906,341.5495784767874,10.79836224412811,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-340R-PD,Solaria Corporation,Mono-c-Si,0,340.0,308.8,1.81,,,360.0,9.43,46.6,8.86,38.2,0.0045829799999999995,-0.1439474,47.1,1.8794683211505314,9.438151172739213,1.5882041554436558e-10,0.3122768556607419,361.2695978056728,10.260186325056079,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-345R-AC,Solaria Corporation,Mono-c-Si,0,345.0,313.5,1.81,,,360.0,9.46,46.9,8.93,38.5,0.0045975600000000005,-0.1448741,47.1,1.8884571128861205,9.46465111306474,1.5377973194126034e-10,0.30671332353002156,623.8309733969515,9.927744098684451,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-345R-BD,Solaria Corporation,Mono-c-Si,0,345.0,313.5,1.81,,,360.0,9.4,47.1,8.88,38.9,0.004568399999999999,-0.1454919,47.1,1.9021269116120674,9.404003507626763,1.6447009888811634e-10,0.2790701133849522,655.2402085274794,10.580411168152635,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-345R-PD,Solaria Corporation,Mono-c-Si,0,345.0,313.5,1.81,,,360.0,9.46,46.9,8.93,38.5,0.0045975600000000005,-0.1448741,47.1,1.8884571128861205,9.46465111306474,1.5377973194126034e-10,0.30671332353002156,623.8309733969515,9.927744098684451,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-350R-AC,Solaria Corporation,Mono-c-Si,0,350.0,318.2,1.81,,,360.0,9.49,47.1,9.02,38.8,0.00461214,-0.1454919,47.1,1.8939126459282007,9.490003556952841,1.5022023738040465e-10,0.2901171805188956,774143.9054426376,9.667003217798422,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-350R-BD,Solaria Corporation,Mono-c-Si,0,350.0,318.2,1.81,,,360.0,9.44,47.4,8.94,39.2,0.004587839999999999,-0.1464186,47.1,1.9131834838465076,9.442407874572815,1.6337936518999741e-10,0.2732068090168325,1071.099302643508,10.473691109992076,-0.4202,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-350R-PD,Solaria Corporation,Mono-c-Si,0,350.0,318.2,1.81,,,36.0,9.49,47.1,9.02,38.8,0.00461214,-0.1453506,47.1,1.8936090361506022,9.490003557758973,1.4962244653023438e-10,0.29018824663497644,774157.5527323661,9.739056199070282,-0.4201,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-355R-AC,Solaria Corporation,Mono-c-Si,0,355.0,322.9,1.81,,,360.0,9.53,47.4,9.09,39.1,0.00463158,-0.1464186,47.1,1.9102420399623583,9.530002542861382,1.5946933432002712e-10,0.26678031948830566,999999.9416760459,10.158686758251354,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-355R-BD,Solaria Corporation,Mono-c-Si,0,355.0,323.0,1.81,,,360.0,9.48,47.7,8.99,39.5,0.0,-0.1431,47.1,1.8330674019506783,9.483171753317505,4.7122450499711764e-11,0.28930416587248464,864.696379482964,3.512577427711123,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-355R-PD,Solaria Corporation,Mono-c-Si,0,355.0,322.9,1.81,,,360.0,9.53,47.4,9.09,39.1,0.00463158,-0.1464186,47.1,1.9102420399623583,9.530002542861382,1.5946933432002712e-10,0.26678031948830566,999999.9416760459,10.158686758251354,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-355R-PD-L,Solaria Corporation,Mono-c-Si,0,355.0,322.9,1.81,,,36.0,9.53,47.4,9.09,39.1,0.00463158,-0.1464186,47.1,1.9102420399623583,9.530002542861382,1.5946933432002712e-10,0.26678031948830566,999999.9416760459,10.158686758251354,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-360R-AC,Solaria Corporation,Mono-c-Si,0,360.0,327.6,1.81,,,360.0,9.56,47.7,9.13,39.5,0.00464616,-0.1473453,47.1,1.9268542319533637,9.560002328706753,1.6956369209368533e-10,0.24354686083300342,999999.890330413,10.676580604905844,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-360R-PD,Solaria Corporation,Mono-c-Si,0,360.0,327.6,1.81,,,36.0,9.56,47.7,9.13,39.5,0.00464616,-0.1472022,47.1,1.9265425231279338,9.560002329761453,1.6888588919167723e-10,0.2436527556055928,999991.7615125601,10.74913742827029,-0.4201,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-360R-PD-L,Solaria Corporation,Mono-c-Si,0,360.0,327.6,1.81,,,36.0,9.56,47.7,9.13,39.5,0.00464616,-0.1473453,47.1,1.9268542319533637,9.560002328706753,1.6956369209368533e-10,0.24354686083300342,999999.890330413,10.676580604905844,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-365R-AC,Solaria Corporation,Mono-c-Si,0,365.0,332.4,1.81,,,36.0,9.58,48.0,9.16,39.9,0.004655879999999999,-0.148272,47.1,1.9434355313142493,9.580002115438896,1.7985740026545654e-10,0.22078121797701739,999999.7997470354,11.18450020772109,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-365R-PD,Solaria Corporation,Mono-c-Si,0,365.0,332.4,1.81,,,36.0,9.58,48.0,9.16,39.9,0.004655879999999999,-0.148272,47.1,1.9434355313142493,9.580002115438896,1.7985740026545654e-10,0.22078121797701739,999999.7997470354,11.18450020772109,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-365R-PD-L,Solaria Corporation,Mono-c-Si,0,365.0,332.4,1.81,,,36.0,9.58,48.0,9.16,39.9,0.004655879999999999,-0.148272,47.1,1.9434355313142493,9.580002115438896,1.7985740026545654e-10,0.22078121797701739,999999.7997470354,11.18450020772109,-0.4202,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-370R-PD,Solaria Corporation,Mono-c-Si,0,370.0,334.5,1.81,,,36.0,9.6,48.3,9.2,40.2,0.0047424,-0.1559607,48.0,1.9967580325174987,9.600001830718282,2.9993598160493665e-10,0.19065270138931414,999998.8211187563,10.778674631909503,-0.4351,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-375R-PD,Solaria Corporation,Mono-c-Si,0,375.0,339.2,1.81,,,36.0,9.65,48.7,9.24,40.6,0.0047671,-0.1572523,48.0,2.014046023485064,9.650001815913425,3.0423239818073415e-10,0.18813133084927594,999999.5136407966,10.859335105673406,-0.4351,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation PowerX-380R-2B,Solaria Corporation,Mono-c-Si,0,380.0,348.9,1.9,,,12.0,13.34,36.45,12.44,30.59,0.012059359999999998,-0.11113605000000001,50.3,1.4223194113905449,13.355864746629832,9.634934810308627e-11,0.11820834860503748,99.39644343652866,3.861730204639993,-0.3342,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation PowerX-390R,Solaria Corporation,Mono-c-Si,0,390.0,355.5,1.95,,,12.0,13.5,36.84,12.56,30.82,0.006750000000000001,-0.10035216000000001,50.3,1.4103917794325422,13.520151515845411,5.934427526164512e-11,0.131392890953272,88.02335542552296,12.348939309471717,-0.3617,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation PowerX-390R-4T,Solaria Corporation,Mono-c-Si,1,390.0,361.5,2.1,,,12.0,13.34,36.92,12.16,32.09,0.0071502399999999995,-0.1041144,45.6,1.46104843890907,13.344327851653615,1.3357060600388742e-10,0.0159403385772723,49.1338735913737,16.00874353982669,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation PowerX-395R,Solaria Corporation,Mono-c-Si,0,395.0,360.2,1.95,,,12.0,13.59,37.03,12.75,31.0,0.006795,-0.10086972,50.3,1.412164004174739,13.60357661758335,5.449253855390117e-11,0.13010371943823276,130.23196345605447,11.481821124553873,-0.3617,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solaria Corporation PowerX-395R-4T,Solaria Corporation,Mono-c-Si,1,395.0,366.3,2.1,,,12.0,13.36,36.94,12.17,32.49,0.00716096,-0.1041708,45.6,1.3593760222203093,13.360292102905763,1.9820543019729956e-11,0.00099999286420471,45.73697971210191,-0.5675923399881336,-0.3579,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-395R-PM,Solaria Corporation,Mono-c-Si,0,395.0,359.4,1.98,,,380.0,9.78,50.7,9.38,42.13,0.00510516,-0.1657383,46.7,2.0896838159692135,9.780001970884863,2.840959255786413e-10,0.20147593846451398,999997.5414267513,8.741127212461178,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-395R-PM-AC,Solaria Corporation,Mono-c-Si,0,395.0,359.4,1.98,,,38.0,9.78,50.7,9.38,42.13,0.00510516,-0.1657383,46.7,2.0896838159692135,9.780001970884863,2.840959255786413e-10,0.20147593846451398,999997.5414267513,8.741127212461178,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation PowerX-400R,Solaria Corporation,Mono-c-Si,0,400.0,364.9,1.95,,,12.0,13.68,37.2,12.84,31.17,0.006840000000000001,-0.1013328,50.3,1.4189942223594996,13.693115601721802,5.522996746695961e-11,0.12739490704432133,132.87711016216076,11.541950968892031,-0.3617,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation PowerX-400R-4T,Solaria Corporation,Mono-c-Si,1,400.0,371.0,2.1,,,12.0,13.42,37.04,12.24,32.69,0.007193120000000001,-0.1044528,45.6,1.3126397906931122,13.420294406044805,7.0103169681692675e-12,0.0009999960605761614,45.58312362450888,-8.685181707118213,-0.3579,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-400R-PM,Solaria Corporation,Mono-c-Si,0,400.0,364.1,1.98,,,38.0,9.82,51.1,9.41,42.4,0.005126040000000001,-0.16704590000000002,46.7,2.103831237116322,9.82000210639054,2.776653943777496e-10,0.21445110349158938,999998.6636309548,8.504822751914238,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-400R-PM-AC,Solaria Corporation,Mono-c-Si,0,400.0,364.1,1.98,,,38.0,9.82,51.1,9.41,42.4,0.005126040000000001,-0.16704590000000002,46.7,2.103831237116322,9.82000210639054,2.776653943777496e-10,0.21445110349158938,999998.6636309548,8.504822751914238,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation PowerX-405R,Solaria Corporation,Mono-c-Si,0,405.0,369.6,1.95,,,12.0,13.78,37.36,12.92,31.36,0.00689,-0.10176864,50.3,1.4271932357991097,13.793568995658504,5.773424155914917e-11,0.12191489956714041,123.81073557532584,11.881865907462924,-0.3617,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation PowerX-405R-4T,Solaria Corporation,Mono-c-Si,1,405.0,375.8,2.1,,,12.0,13.48,37.1,12.33,32.85,0.007225280000000001,-0.10462199999999999,45.6,1.2683770586489373,13.48028758274426,2.513717308895559e-12,0.0009999901050641363,46.87300224549394,-16.13145098997471,-0.3579,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-405R-PM,Solaria Corporation,Mono-c-Si,0,405.0,368.8,1.98,,,38.0,9.85,51.4,9.46,42.8,0.005141700000000001,-0.16802660000000003,46.7,2.1219632835513043,9.850001820264339,2.975662077282792e-10,0.18475570887851214,999990.8563072175,9.085382673844174,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-410R-PM,Solaria Corporation,Mono-c-Si,0,410.0,373.6,1.98,,,380.0,9.87,51.7,9.5,43.2,0.00515214,-0.16900730000000003,46.7,2.1408343420544544,9.870123080176937,3.2074371192534896e-10,0.15267721698655365,12243.467350497085,9.730805652803655,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-410R-PM-AC,Solaria Corporation,Mono-c-Si,0,410.0,373.6,1.98,,,38.0,9.87,51.7,9.5,43.2,0.00515214,-0.16900730000000003,46.7,2.1408343420544544,9.870123080176937,3.2074371192534896e-10,0.15267721698655365,12243.467350497085,9.730805652803655,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation PowerXT-415R-PL,Solaria Corporation,Mono-c-Si,0,415.0,380.4,2.1,,,68.0,11.5,45.7,11.0,37.6,0.005221000000000001,-0.1335811,47.2,1.7660348695898405,11.500004718686313,6.643229446676612e-11,0.25044277423554323,610394.1423484286,6.932771945669994,-0.3874,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-415R-PM,Solaria Corporation,Mono-c-Si,0,415.0,378.3,1.98,,,38.0,9.92,52.1,9.55,43.5,0.00517824,-0.17031490000000002,46.7,2.1568004683356587,9.92012611185066,3.202192058952553e-10,0.155688312995866,12246.526744463377,9.671609262742276,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation PowerXT-420R-PL,Solaria Corporation,Mono-c-Si,0,420.0,385.1,2.1,,,68.0,11.6,45.7,11.09,37.9,0.0052664,-0.1335811,47.2,1.7719032048067431,11.600004255180052,7.30061259554185e-11,0.21727416992406973,592340.7319360084,7.673912237513811,-0.3874,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation Solaria PowerXT-420R-PM,Solaria Corporation,Mono-c-Si,0,420.0,383.0,1.98,,,380.0,9.94,52.4,9.6,43.8,0.00518868,-0.17129560000000002,46.7,2.1737209620949836,9.940105417493507,3.373213753058803e-10,0.1292409162865711,12186.383388902694,10.115042533860725,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation Solaria PowerXT-420R-PM-AC,Solaria Corporation,Mono-c-Si,0,420.0,383.0,1.98,,,38.0,9.94,52.4,9.6,43.8,0.00518868,-0.17129560000000002,46.7,2.1737209620949836,9.940105417493507,3.373213753058803e-10,0.1292409162865711,12186.383388902694,10.115042533860725,-0.4295,N,2025.7.3,6/23/2025,2.0,first_pass +Solaria Corporation PowerXT-425R-PL,Solaria Corporation,Mono-c-Si,0,425.0,389.8,2.1,,,68.0,11.74,45.7,11.22,37.9,0.005329960000000001,-0.1335811,47.2,1.772473111517591,11.740412006085426,7.445816947277458e-11,0.2146044482097387,6115.098145698324,7.742863378502064,-0.3874,N,2025.7.3,6/23/2025,4.0,first_pass +Solaria Corporation PowerXT-430R-PL,Solaria Corporation,Mono-c-Si,0,430.0,394.6,2.1,,,68.0,11.87,45.7,11.35,37.9,0.005388980000000001,-0.1335811,47.2,1.772030386073201,11.870004348573953,7.484382171696287e-11,0.212299965781576,579531.8345817714,7.689974958303711,-0.3874,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US310,SolarJuice American Inc,Mono-c-Si,0,310.0,283.6,1.65,,,60.0,10.04,40.3,9.52,32.61,0.00052208,-0.10691589999999998,46.8,1.4934411624796926,10.044010291092627,1.9077258786843435e-11,0.33179748085688465,830.6745732430549,8.30332918726962,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US310B,SolarJuice American Inc,Mono-c-Si,0,310.0,283.4,1.65,,,60.0,10.04,40.3,9.52,32.61,0.0005521999999999999,-0.0990977,48.2,1.4554746547570512,10.045319029917508,9.424408571415071e-12,0.34041956383597477,642.5631238033982,10.402619308604601,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US315,SolarJuice American Inc,Mono-c-Si,0,315.0,288.3,1.65,,,60.0,10.11,40.53,9.58,32.9,0.0005257199999999999,-0.10752608999999999,46.8,1.504817755437909,10.114849102262351,2.0196037404652273e-11,0.3188788240127309,664.8374971926852,8.744440364814862,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US315B,SolarJuice American Inc,Mono-c-Si,0,315.0,288.1,1.65,,,60.0,10.11,40.53,9.58,32.9,0.00055605,-0.09966327,48.2,1.466481217042114,10.116140014552647,9.975295727225875e-12,0.32755302847104706,539.3409309142569,10.853120422488022,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US320,SolarJuice American Inc,Mono-c-Si,0,320.0,293.1,1.65,,,60.0,10.18,40.78,9.65,33.18,0.00052936,-0.10818934,46.8,1.5156019447050382,10.1845613283535,2.089014733286121e-11,0.30940745066189773,690.5374281929802,8.978822411452972,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US320B,SolarJuice American Inc,Mono-c-Si,0,320.0,292.8,1.65,,,60.0,10.18,40.78,9.65,33.18,0.0005599,-0.10027802,48.2,1.4769477197137808,10.18581798007528,1.0317081447068005e-11,0.31810501173135913,556.6035590522451,11.092333972590579,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US325,SolarJuice American Inc,Mono-c-Si,0,325.0,297.8,1.65,,,60.0,10.25,41.04,9.72,33.45,0.000533,-0.10887911999999998,46.8,1.5263392621077077,10.254268739597443,2.144140789443943e-11,0.30230535136817815,725.8887280912743,9.145924093446256,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US325B,SolarJuice American Inc,Mono-c-Si,0,325.0,297.6,1.65,,,60.0,10.25,41.04,9.72,33.45,0.00056375,-0.10091736,48.2,1.4873805050682383,10.255499091109776,1.058857768884657e-11,0.31101932148811595,579.7227278179477,11.262869279540544,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US330,SolarJuice American Inc,Mono-c-Si,0,330.0,302.5,1.65,,,60.0,10.32,41.3,9.78,33.76,0.00053664,-0.10956889999999998,46.8,1.5387369455610138,10.324981833806019,2.2617525584294074e-11,0.2905850115415679,601.9545247491031,9.559686723918148,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US330B,SolarJuice American Inc,Mono-c-Si,0,330.0,302.3,1.65,,,60.0,10.32,41.3,9.78,33.76,0.0005675999999999999,-0.1015567,48.2,1.4993847003495018,10.326197701388066,1.116760334784946e-11,0.2993537687975971,498.46398506222977,11.685431916455846,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US335,SolarJuice American Inc,Mono-c-Si,0,335.0,307.2,1.65,,,60.0,10.39,41.59,9.85,34.07,0.00054028,-0.11033827,46.8,1.5509456693443266,10.394689722031348,2.333598521916783e-11,0.2821124095077643,625.0152987917179,9.77465712230607,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US335B,SolarJuice American Inc,Mono-c-Si,0,335.0,307.0,1.65,,,60.0,10.39,41.59,9.85,34.07,0.00057145,-0.10226981000000002,48.2,1.5112411736551414,10.395873417609165,1.1521332051567095e-11,0.2909104115103268,514.616772462106,11.904824967610447,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-360,SolarJuice American Inc,Mono-c-Si,0,360.0,334.0,1.82,,,60.0,11.15,40.7,10.5,34.3,0.0037352500000000003,-0.11973940000000001,45.5,1.5374701392539556,11.158176772725628,3.493686371787805e-11,0.1533910574312434,209.16691250174011,1.3364317194242623,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-365,SolarJuice American Inc,Mono-c-Si,0,365.0,338.7,1.82,,,60.0,11.2,40.9,10.56,34.6,0.0037519999999999997,-0.1203278,45.5,1.5471458992098648,11.20695201522684,3.642978631755149e-11,0.1393131800838252,224.43961592910676,1.6383636375568638,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-370,SolarJuice American Inc,Mono-c-Si,0,370.0,343.5,1.82,,,60.0,11.26,41.1,10.61,34.9,0.0037721000000000005,-0.12091620000000002,45.5,1.5582535810450702,11.266666066137162,3.8851855628555876e-11,0.12496890852610061,211.09150316581471,2.126923860495421,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-375,SolarJuice American Inc,Mono-c-Si,0,375.0,348.3,1.82,,,60.0,11.31,41.3,10.66,35.2,0.0037888500000000003,-0.1215046,45.5,1.547520883931506,11.31000346892041,2.9045174732848924e-11,0.11522602674792679,375684.8316336818,-0.33635792019653576,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US375,SolarJuice American Inc,Mono-c-Si,0,375.0,349.2,1.97,,,72.0,9.99,48.44,9.45,39.74,0.00132867,-0.11218704,46.2,1.678408304422058,9.999916571723533,2.8854058631173667e-12,0.36516629781474724,367.87021009190477,6.436968889175587,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US380,SolarJuice American Inc,Mono-c-Si,0,380.0,354.0,1.97,,,72.0,10.06,48.7,9.51,40.02,0.0013379800000000001,-0.1127892,46.2,1.6892181361339451,10.070481760067667,2.9936485521793085e-12,0.35659217636437596,342.2437909853039,6.701664558138126,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US385,SolarJuice American Inc,Mono-c-Si,0,385.0,358.8,1.97,,,72.0,10.12,48.97,9.57,40.28,0.00134596,-0.11341452,46.2,1.6990773997330426,10.130157500082111,3.037788349222909e-12,0.3518912193858284,350.5920839278149,6.776309667608939,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US390,SolarJuice American Inc,Mono-c-Si,0,390.0,363.6,1.97,,,72.0,10.17,49.27,9.62,40.6,0.00135261,-0.11410932,46.2,1.710714137180687,10.179817810114862,3.117090029668755e-12,0.343619503146458,355.94601174090656,6.958074306597183,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US395,SolarJuice American Inc,Mono-c-Si,0,395.0,368.3,1.97,,,72.0,10.23,49.56,9.67,40.89,0.00136059,-0.11478096000000002,46.2,1.7223240516306988,10.240397730238598,3.2143050318873455e-12,0.33760290555126515,332.15688858900506,7.1798910561454505,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4A-US400,SolarJuice American Inc,Mono-c-Si,0,400.0,373.1,1.97,,,72.0,10.29,49.86,9.73,41.18,0.0013685699999999997,-0.11547576,46.2,1.7333264480831878,10.300072033321383,3.265224585990094e-12,0.3326880671004464,339.88769772599665,7.265232065655808,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144B-435C {Clr},SolarJuice American Inc,Mono-c-Si,1,435.0,406.2,2.173572,,,144.0,11.53,49.6,10.7,40.7,0.004612,-0.12796800000000003,44.3,1.8469286611550826,11.557131439482534,2.425629243475664e-11,0.299919759570255,127.4563720470795,11.93968949045567,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144S-435C,SolarJuice American Inc,Mono-c-Si,0,435.0,407.9,2.17,,,144.0,11.53,49.6,10.7,40.7,0.0051884999999999995,-0.14384,44.6,1.8124320594389705,11.55855936722811,1.453661946618541e-11,0.30702360180732224,123.95170051473406,-4.587488976032579,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144B-440C {Clr},SolarJuice American Inc,Mono-c-Si,1,440.0,411.0,2.173572,,,144.0,11.6,49.8,10.77,40.9,0.00464,-0.12848400000000001,44.3,1.8547900559161703,11.626535418463506,2.456171174862454e-11,0.29548166323842473,129.17027539031216,11.996551961613104,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144S-440C,SolarJuice American Inc,Mono-c-Si,0,440.0,412.7,2.17,,,144.0,11.6,49.8,10.77,40.9,0.00522,-0.14442,44.6,1.8201570425526488,11.627950579149475,1.4723650681775388e-11,0.3025711735422142,125.5725545143879,-4.536674148572452,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144B-445C {Clr},SolarJuice American Inc,Mono-c-Si,1,445.0,415.7,2.173572,,,144.0,11.72,49.9,10.86,41.0,0.004688,-0.128742,44.3,1.8607369719179185,11.748590698187956,2.556370073761062e-11,0.29104237903390423,119.30512070306027,12.274881095531793,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144S-445C,SolarJuice American Inc,Mono-c-Si,0,445.0,417.5,2.17,,,144.0,11.72,49.9,10.86,41.0,0.005274,-0.14470999999999998,44.6,1.8260215048349218,11.750061001105472,1.5340313025579577e-11,0.2980953992413331,116.21961880598715,-4.290526179392853,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144B-450C {Clr},SolarJuice American Inc,Mono-c-Si,1,450.0,420.5,2.173572,,,144.0,11.83,50.0,10.96,41.1,0.004732,-0.129,44.3,1.8650468311825343,11.858866663963065,2.6013510685450927e-11,0.2870232213744862,117.62650263418949,12.349467620835577,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144S-450C,SolarJuice American Inc,Mono-c-Si,0,450.0,422.3,2.17,,,144.0,11.83,50.0,10.96,41.1,0.0053235,-0.145,44.6,1.8302605034147752,11.86034955947689,1.5614962745243187e-11,0.29402872916613026,114.6098966890609,-4.224348473293722,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144B-530C {Clr},SolarJuice American Inc,Mono-c-Si,1,530.0,488.8,2.588905,,,144.0,13.76,49.2,12.83,41.35,0.0046784,-0.12546000000000002,46.0,1.9050985191077214,13.776484742029949,8.145182183739543e-11,0.15207990615495467,126.94281335410204,23.180804478006618,-0.387,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144S-530C,SolarJuice American Inc,Mono-c-Si,0,530.0,490.4,2.588905,,,144.0,13.76,49.2,12.83,41.35,0.004816000000000001,-0.12546000000000002,45.9,1.8767610935616574,13.777457869860438,5.51132067414209e-11,0.15697084653761784,123.72178739060597,19.359656634861604,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144B-535C {Clr},SolarJuice American Inc,Mono-c-Si,1,535.0,493.5,2.588905,,,144.0,13.83,49.35,12.9,41.5,0.0047022,-0.12584250000000002,46.0,1.9111230363845504,13.846107391907937,8.213694916212062e-11,0.14968494553122652,128.5212919116009,23.211979124317455,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144S-535C,SolarJuice American Inc,Mono-c-Si,0,535.0,495.2,2.588905,,,144.0,13.83,49.35,12.9,41.5,0.004840500000000001,-0.12584250000000002,45.9,1.882694244781359,13.847071562597044,5.557788230184501e-11,0.1545666383153412,125.21739650062852,19.390085763966347,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +SolarJuice American Inc S4AI-144B-540C {Clr},SolarJuice American Inc,Mono-c-Si,1,540.0,498.3,2.588905,,,144.0,13.9,49.5,12.97,41.65,0.004726000000000001,-0.126225,46.0,1.9171485937296937,13.91573610184514,8.28250146265986e-11,0.1473156860033431,130.12676685626934,23.243091009726793,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144S-540C,SolarJuice American Inc,Mono-c-Si,0,540.0,500.0,2.588905,,,144.0,13.9,49.5,12.97,41.65,0.004865000000000001,-0.126225,45.9,1.8886283738791139,13.91669131662946,5.604453360153006e-11,0.1521882402347443,126.73754868440501,19.420450029998445,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144B-545C {Clr},SolarJuice American Inc,Mono-c-Si,1,545.0,503.0,2.588905,,,144.0,13.95,49.65,13.05,41.8,0.004743,-0.1266075,46.0,1.9210106067427852,13.963878001254551,8.121648107052862e-11,0.14553214501071662,146.2871639781738,23.000679028855753,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144S-545C,SolarJuice American Inc,Mono-c-Si,0,545.0,504.7,2.588905,,,144.0,13.95,49.65,13.05,41.8,0.0048825,-0.1266075,45.9,1.89245382745456,13.964772370613668,5.4950079915303894e-11,0.1503801393483891,142.0085519522243,19.184077760503573,-0.373,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144B-550C {Clr},SolarJuice American Inc,Mono-c-Si,1,550.0,507.8,2.588905,,,144.0,14.0,49.8,13.12,41.95,0.004760000000000001,-0.12699,46.0,1.9256406263956032,14.012571738585487,8.039763318415257e-11,0.14364320747047823,159.96235642096485,22.856407876915082,-0.387,N,2025.7.3,6/23/2025,2.0,first_pass +SolarJuice American Inc S4AI-144S-550C,SolarJuice American Inc,Mono-c-Si,0,550.0,509.5,2.588905,,,144.0,14.0,49.8,13.12,41.95,0.004900000000000001,-0.12699,45.9,1.897027774568833,14.013423272861433,5.43925920074535e-11,0.14847478443077192,154.85396312143402,19.04340647166617,-0.373,N,2025.7.3,6/23/2025,4.0,first_pass +Solarmax SEAP60-230,Solarmax,Mono-c-Si,0,230.0,204.9,1.6288719999999999,1.652,0.986,60.0,8.32,36.85,7.92,29.05,0.004780672000000001,-0.12090485,46.6,1.5521931219377656,8.320003247963463,4.0710729503476387e-10,0.3900329550372622,999999.144261222,12.937264431748169,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP60-235,Solarmax,Mono-c-Si,0,235.0,209.5,1.6288719999999999,1.652,0.986,60.0,8.41,37.24,8.0,29.36,0.004832386,-0.12218444,46.6,1.5681642593951528,8.410003306442219,4.0867747674447175e-10,0.3928049629342179,999999.5115350966,12.874187632936668,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP60-240,Solarmax,Mono-c-Si,0,240.0,214.1,1.6288719999999999,1.652,0.986,60.0,8.5,37.64,8.09,29.67,0.0048841,-0.12349684000000001,46.6,1.5852764190014705,8.500003327174726,4.14714347360284e-10,0.39108361074679576,999999.2714282857,12.910871379188295,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP60-245,Solarmax,Multi-c-Si,0,245.0,218.7,1.6288719999999999,1.652,0.986,60.0,8.59,38.03,8.17,29.98,0.004935814,-0.12477643000000001,46.6,1.601247707074774,8.590003385582476,4.162918802559181e-10,0.39377823860873573,999999.5677042253,12.849396033783211,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP60-250,Solarmax,Multi-c-Si,0,250.0,223.3,1.6288719999999999,1.652,0.986,60.0,8.68,38.41,8.26,30.28,0.004987528,-0.12602321,46.6,1.617661714587605,8.680003398073262,4.2321913514812244e-10,0.39113393394073087,999999.3726810998,12.904889807837876,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP60-255,Solarmax,Multi-c-Si,0,255.0,227.9,1.6288719999999999,1.652,0.986,60.0,8.76,38.8,8.34,30.59,0.005033495999999999,-0.1273028,46.6,1.6345056396220012,8.760003411191922,4.297263728857656e-10,0.38905949472596224,999999.1284254091,12.960444577384191,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP60-260,Solarmax,Multi-c-Si,0,260.0,232.5,1.6288719999999999,1.652,0.986,60.0,8.85,39.18,8.42,30.88,0.00508521,-0.12854958,46.6,1.6497525620657885,8.85000348256728,4.2941273250845807e-10,0.3931588791243206,999999.4629045861,12.860465434274166,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP72-280,Solarmax,Multi-c-Si,0,280.0,249.6,1.940448,1.968,0.986,72.0,8.38,44.53,7.98,35.11,0.004815148000000001,-0.14610293000000002,46.6,1.8761487891544608,8.380003901308186,4.12432625354762e-10,0.46520558407249085,999999.120559371,12.990337316587008,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP72-285,Solarmax,Multi-c-Si,0,285.0,254.2,1.940448,1.968,0.986,72.0,8.46,44.93,8.05,35.42,0.004861116,-0.14741533,46.6,1.8921871559429102,8.46000397789239,4.1213748804679085e-10,0.4698504101230506,999999.5013530104,12.897035268893653,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP72-290,Solarmax,Multi-c-Si,0,290.0,258.8,1.940448,1.968,0.986,72.0,8.53,45.32,8.12,35.73,0.004901338,-0.14869492,46.6,1.9090486680360828,8.530003990127094,4.178124907121234e-10,0.46742896145307594,999999.3334919134,12.946662330647957,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP72-295,Solarmax,Multi-c-Si,0,295.0,263.4,1.940448,1.968,0.986,72.0,8.6,45.71,8.19,36.04,0.004941559999999999,-0.14997451,46.6,1.9259105058980353,8.60000400222229,4.2349850271881205e-10,0.46503068792664376,999999.1042464057,12.995479397891243,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP72-300,Solarmax,Multi-c-Si,0,300.0,268.0,1.940448,1.968,0.986,72.0,8.68,46.1,8.26,36.34,0.004987528,-0.1512541,46.6,1.9414745686559989,8.680004080367455,4.229268984648784e-10,0.4697389473581687,999999.4832700111,12.898586942483949,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarmax SEAP72-305,Solarmax,Multi-c-Si,0,305.0,272.6,1.940448,1.968,0.986,72.0,8.75,46.48,8.32,36.64,0.00502775,-0.15250088,46.6,1.9567619049332612,8.750004151012982,4.226486898146142e-10,0.47404729992492767,999999.7092400275,12.81929105812476,-0.4736,N,2025.7.3,6/23/2025,2.0,first_pass +Solarspace Technology Co Ltd SS8-54HSB-395M,Solarspace Technology Co Ltd,Mono-c-Si,0,395.0,377.0,1.32,,,54.0,13.7,36.98,12.81,30.84,0.00548,-0.08801239999999999,43.1,1.321230214482291,13.721885568582659,9.325109400237652e-12,0.15463253231607105,96.79737993110444,10.757128737425568,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HSB-400M,Solarspace Technology Co Ltd,Mono-c-Si,0,400.0,381.9,1.32,,,54.0,13.79,37.07,12.9,31.01,0.005516,-0.0882266,43.1,1.3261432811604041,13.81056929384555,9.731166942298906e-12,0.14560429862111493,97.6155669951444,11.083013935742434,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HSB-405M,Solarspace Technology Co Ltd,Mono-c-Si,0,405.0,386.8,1.32,,,54.0,13.87,37.23,12.98,31.21,0.005548,-0.08860739999999999,43.1,1.332994009378326,13.889616082481288,1.0024394213004019e-11,0.1395876423300495,98.6986369404687,11.298971476043938,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-415N,Solarspace Technology Co Ltd,Mono-c-Si,0,415.0,391.7,1.94,,,54.0,13.91,37.7,13.11,31.67,0.0057031,-0.08784100000000002,45.74,1.2957092561166994,13.925247235007426,3.1517035519392272e-12,0.14451873707880306,131.84394707186513,3.3342765408832995,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-420N,Solarspace Technology Co Ltd,Mono-c-Si,0,420.0,396.5,1.94,,,54.0,13.99,37.89,13.19,31.85,0.0057359,-0.0882837,45.74,1.3024241851657197,14.004872609641355,3.184061537786229e-12,0.14267866541078608,134.21145170772897,3.3712016273616467,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-425N,Solarspace Technology Co Ltd,Mono-c-Si,0,425.0,401.3,1.94,,,54.0,14.07,38.08,13.28,32.03,0.005768700000000001,-0.0887264,45.74,1.308693686430456,14.08384268904334,3.1876093912111414e-12,0.14090020881586246,143.21393288831675,3.3270761067043093,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-430N,Solarspace Technology Co Ltd,Mono-c-Si,0,430.0,406.2,1.94,,,54.0,14.13,38.27,13.36,32.21,0.0057933,-0.08916910000000002,45.74,1.3145707122350538,14.142236071801406,3.1615595962544966e-12,0.13937732941950107,160.95048299644432,3.212628319652601,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-435N,Solarspace Technology Co Ltd,Mono-c-Si,0,435.0,411.0,1.94,,,54.0,14.21,38.46,13.44,32.37,0.005826100000000001,-0.0896118,45.74,1.3209061029870781,14.222019493723158,3.167293842280291e-12,0.1392904152465942,164.6755552323355,3.1783674246143367,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-440N,Solarspace Technology Co Ltd,Mono-c-Si,0,440.0,415.8,1.94,,,54.0,14.29,38.65,13.52,32.55,0.0058589,-0.09005450000000001,45.74,1.32762183962946,14.301693639841092,3.1994614112271934e-12,0.13752642923080233,168.06167324599647,3.2154477557512178,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-445N,Solarspace Technology Co Ltd,Mono-c-Si,0,445.0,420.7,1.94,,,54.0,14.37,38.84,13.6,32.73,0.0058917,-0.09049720000000001,45.74,1.3343375080590212,14.381373970761798,3.2317020966492025e-12,0.13578334350202415,171.5501728580881,3.2521496380047363,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-54HDB-450N,Solarspace Technology Co Ltd,Mono-c-Si,0,450.0,425.5,1.94,,,54.0,14.45,39.03,13.68,32.91,0.0059245,-0.09093990000000002,45.74,1.3410531096975757,14.461060377759386,3.2640151206263868e-12,0.13406078884100173,175.14577212666728,3.2884786734964413,-0.288,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-60HD-470N,Solarspace Technology Co Ltd,Mono-c-Si,0,470.0,442.1,2.1,,,60.0,14.16,42.35,13.42,35.03,0.0058056,-0.09698150000000001,48.29,1.4174798774726511,14.173285430859762,1.4799030065744528e-12,0.21005639853542252,223.884239447864,-1.4327340864228986,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-60HD-475N,Solarspace Technology Co Ltd,Mono-c-Si,0,475.0,446.9,2.1,,,60.0,14.24,42.51,13.5,35.19,0.0058384000000000005,-0.0973479,48.29,1.423156672623322,14.252899029553,1.4987741154843283e-12,0.207338337839536,228.89302750425966,-1.375776879851754,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-60HD-480N,Solarspace Technology Co Ltd,Mono-c-Si,0,480.0,451.8,2.1,,,60.0,14.32,42.68,13.58,35.35,0.0058712,-0.09773720000000001,48.29,1.4290157649178847,14.332542628501203,1.512952825073357e-12,0.2053921060756905,234.49749478963628,-1.345489838477025,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-60HD-485N,Solarspace Technology Co Ltd,Mono-c-Si,0,485.0,456.6,2.1,,,60.0,14.4,42.85,13.66,35.51,0.005904000000000001,-0.09812650000000002,48.29,1.4348751799382098,14.412191532885835,1.5271790429385334e-12,0.20346868116843067,240.3265478580036,-1.315393425376564,-0.275,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-525M,Solarspace Technology Co Ltd,Mono-c-Si,0,525.0,495.0,2.56,,,72.0,13.64,49.14,12.75,41.16,0.005319600000000001,-0.1199016,43.2,1.778957915473936,13.659831890741467,1.3385633679623612e-11,0.18689271798738002,128.5412830276396,11.30055898633395,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-530M,Solarspace Technology Co Ltd,Mono-c-Si,0,530.0,499.8,2.56,,,72.0,13.73,49.31,12.83,41.32,0.0053547,-0.1203164,43.2,1.7857646222216939,13.750084393392616,1.3604933001434696e-11,0.184708112481534,126.26930479931924,11.38989710838697,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-535M,Solarspace Technology Co Ltd,Mono-c-Si,0,535.0,504.6,2.56,,,72.0,13.78,49.44,12.9,41.46,0.0053742,-0.1206336,43.2,1.7895824356005081,13.798387366129084,1.349591296257558e-11,0.18193889939075925,136.35003640722152,11.27588215727621,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-540M,Solarspace Technology Co Ltd,Mono-c-Si,0,540.0,509.4,2.56,,,72.0,13.85,49.61,12.97,41.65,0.0054015,-0.1210484,43.2,1.7964485483542825,13.867824823535909,1.3718057480120965e-11,0.1774894034842182,137.91038327133916,11.376717576583431,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-545M,Solarspace Technology Co Ltd,Mono-c-Si,0,545.0,514.3,2.56,,,72.0,13.92,49.76,13.04,41.81,0.005428799999999999,-0.12141439999999999,43.2,1.802309439034315,13.937373953662707,1.3882882120955863e-11,0.17417611799132166,139.54978815182463,11.438003313473944,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-550M,Solarspace Technology Co Ltd,Mono-c-Si,0,550.0,519.1,2.56,,,72.0,14.02,49.91,13.1,41.97,0.005467799999999999,-0.1217804,43.2,1.810704517066173,14.039276043239065,1.45834524068559e-11,0.1702155031775858,123.80244897213224,11.832566960364252,-0.329,N,2025.7.3,6/23/2025,2.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-555M,Solarspace Technology Co Ltd,Mono-c-Si,0,555.0,523.9,2.56,,,72.0,14.07,50.03,13.17,42.15,0.0054873000000000005,-0.12207319999999999,43.2,1.8151906578293642,14.087289402502341,1.4692989090933076e-11,0.16334226024817225,132.92683514104527,11.860640615479461,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-555N,Solarspace Technology Co Ltd,Mono-c-Si,0,555.0,523.5,2.56,,,72.0,14.06,50.48,13.29,41.77,0.004780400000000001,-0.11812320000000001,45.67,1.7174490690580315,14.075393768758648,2.3796722043495004e-12,0.24650457026768385,225.1465717125221,0.5177832859956507,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-560N,Solarspace Technology Co Ltd,Mono-c-Si,0,560.0,528.8,2.56,,,72.0,13.51,53.01,12.87,43.52,0.00636321,-0.11762919,43.3,1.884836146345801,13.512920366869478,8.225259449600046e-12,0.2833766838497762,1310.9377218016782,17.566643962385356,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-560N,Solarspace Technology Co Ltd,Mono-c-Si,0,560.0,528.3,2.56,,,72.0,14.12,50.68,13.35,41.96,0.0048008,-0.11859120000000001,45.67,1.724534508266615,14.13508262576906,2.4018573449828056e-12,0.24434225374381555,228.74747935154292,0.5587367693561575,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-565N,Solarspace Technology Co Ltd,Mono-c-Si,0,565.0,533.6,2.56,,,72.0,13.56,53.28,12.92,43.74,0.00638676,-0.11822832,43.3,1.8942518971577624,13.562703095797254,8.234920393333434e-12,0.28391409695432746,1424.2466883629106,17.541427163445462,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-565N,Solarspace Technology Co Ltd,Mono-c-Si,0,565.0,533.2,2.56,,,72.0,14.18,50.88,13.41,42.14,0.0048212,-0.11905920000000002,45.67,1.7314293164924792,14.194808961013978,2.4163295885302872e-12,0.2430470116688447,232.72440402277215,0.5724714854643093,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-570N,Solarspace Technology Co Ltd,Mono-c-Si,0,570.0,538.5,2.56,,,72.0,13.61,53.55,12.97,43.95,0.006410310000000001,-0.11882744999999999,43.3,1.9034648864293786,13.612469672772065,8.220209864629085e-12,0.2853289576097974,1572.4055841610946,17.487752926439853,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-570N,Solarspace Technology Co Ltd,Mono-c-Si,0,570.0,538.0,2.56,,,72.0,14.24,51.08,13.48,42.29,0.004841600000000001,-0.11952720000000001,45.67,1.7371891232195387,14.253746074361693,2.3868082638115116e-12,0.2442935928760828,253.0715734998772,0.430064408768488,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-575N,Solarspace Technology Co Ltd,Mono-c-Si,0,575.0,543.3,2.56,,,72.0,13.66,53.82,13.02,44.17,0.0064338600000000004,-0.11942657999999999,43.3,1.9128801189812368,13.662251169422236,8.230112696510114e-12,0.28585490576410993,1734.5554404364632,17.46311785265729,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-575N,Solarspace Technology Co Ltd,Mono-c-Si,0,575.0,542.9,2.56,,,72.0,14.3,51.28,13.55,42.44,0.004862000000000001,-0.11999520000000001,45.67,1.7429533052589647,14.31266917613984,2.3580289856637992e-12,0.24552587339713486,277.13088483812965,0.2893549188408885,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-580N,Solarspace Technology Co Ltd,Mono-c-Si,0,580.0,548.1,2.56,,,72.0,13.71,54.09,13.07,44.39,0.00645741,-0.12002571000000001,43.3,1.92229506140696,13.712032437736438,8.240084835861643e-12,0.2863769200607728,1931.782352868988,17.438689400006332,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-580N,Solarspace Technology Co Ltd,Mono-c-Si,0,580.0,547.7,2.56,,,72.0,14.36,51.48,13.62,42.59,0.0048824,-0.12046319999999999,45.67,1.7487218146856987,14.371578499513172,2.329968256672097e-12,0.24674409497537386,306.01937726245836,0.15031747977934254,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-585N,Solarspace Technology Co Ltd,Mono-c-Si,0,585.0,553.0,2.56,,,72.0,13.76,54.36,13.12,44.61,0.00648096,-0.12062483999999998,43.3,1.931709736326694,13.761813496927484,8.250127382318854e-12,0.28689504191498577,2176.830746123746,17.414466705802965,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-585N,Solarspace Technology Co Ltd,Mono-c-Si,0,585.0,552.5,2.56,,,72.0,14.42,51.68,13.68,42.77,0.0049028000000000006,-0.12093120000000002,45.67,1.7556183745431653,14.431322918516088,2.344281507927833e-12,0.24546328704569048,312.6032046357176,0.16564162598829016,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-590N,Solarspace Technology Co Ltd,Mono-c-Si,0,590.0,557.8,2.56,,,72.0,13.81,54.63,13.17,44.83,0.006504510000000001,-0.12122397,43.3,1.8405870237488398,13.814535705716802,1.7713093890510938e-12,0.30444973162837885,926.9672837664201,3.369502021333834,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-590N,Solarspace Technology Co Ltd,Mono-c-Si,0,590.0,556.1,2.68,,,66.0,15.62,48.18,14.7,40.19,0.00777876,-0.11187396,43.2,1.7699458194505793,15.635800059793658,2.3120070726644814e-11,0.16814561056534547,166.22939931503313,20.780886376870754,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-590N,Solarspace Technology Co Ltd,Mono-c-Si,0,590.0,557.4,2.56,,,72.0,14.48,51.88,13.75,42.92,0.004923200000000001,-0.12139920000000001,45.67,1.7613916257583881,14.490223767119646,2.3168547183436385e-12,0.24666876210548389,349.35886435445605,0.028778762757559237,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-590N,Solarspace Technology Co Ltd,Mono-c-Si,0,590.0,559.1,2.68,,,66.0,15.62,48.18,14.7,40.19,0.0059356,-0.1117776,44.64,1.643406740780966,15.640969281152344,2.833392620680524e-12,0.1875874173740506,139.73371046772647,1.9376661954914924,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-595N,Solarspace Technology Co Ltd,Mono-c-Si,0,595.0,562.7,2.56,,,72.0,13.86,54.9,13.21,45.05,0.0065280600000000005,-0.1218231,43.3,1.9511773331502642,13.862333874676537,8.339635141640634e-12,0.2879343075823311,1709.9331156040262,17.450642415755212,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-595N,Solarspace Technology Co Ltd,Mono-c-Si,0,595.0,560.9,2.68,,,66.0,15.68,48.38,14.77,40.33,0.0078086399999999995,-0.11233836000000001,43.2,1.7759593150812223,15.69504662144486,2.2765212601140958e-11,0.17034107449692906,177.51148069003122,20.586604323891798,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-595N,Solarspace Technology Co Ltd,Mono-c-Si,0,595.0,562.2,2.56,,,72.0,14.54,52.08,13.82,43.06,0.0049436,-0.12186720000000002,45.67,1.766980394894897,14.549120344348442,2.282954630102698e-12,0.24868256717913528,396.45921367847984,-0.1324859410568052,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-595N,Solarspace Technology Co Ltd,Mono-c-Si,0,595.0,563.9,2.68,,,66.0,15.68,48.38,14.77,40.33,0.0059584,-0.11224160000000002,44.64,1.6490427986955973,15.700162098209775,2.788086684951713e-12,0.18973485554385502,147.5561943637276,1.7645635613474024,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-600N,Solarspace Technology Co Ltd,Mono-c-Si,0,600.0,567.5,2.56,,,72.0,13.91,55.17,13.26,45.27,0.00655161,-0.12242223,43.3,1.9605915514734584,13.912114725771461,8.349673507938715e-12,0.2884412305449559,1897.275639038029,17.426660999948304,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-600N,Solarspace Technology Co Ltd,Mono-c-Si,0,600.0,565.8,2.68,,,66.0,15.74,48.58,14.84,40.47,0.00783852,-0.11280276,43.2,1.7819765483419976,15.754265624238943,2.2419626605110506e-11,0.17251474707496306,190.34443132370293,20.394459164432654,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS8-72HD-600N,Solarspace Technology Co Ltd,Mono-c-Si,0,600.0,567.1,2.56,,,72.0,14.6,52.28,13.89,43.21,0.004964,-0.12233520000000002,45.67,1.7727621496335122,14.607990147996082,2.2569585304386225e-12,0.24985699772156258,456.5512674827516,-0.2660399911779512,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-600N,Solarspace Technology Co Ltd,Mono-c-Si,0,600.0,568.8,2.68,,,66.0,15.74,48.58,14.84,40.47,0.0059812,-0.1127056,44.64,1.65468267070892,15.759328165779946,2.7440174783787355e-12,0.1918609809294236,156.24306395131785,1.5934365326061026,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SH8-72HD-605N,Solarspace Technology Co Ltd,Mono-c-Si,0,605.0,572.4,2.56,,,72.0,13.96,55.44,13.31,45.49,0.006575160000000001,-0.12302136,43.3,1.9700055043011864,13.961895369082084,8.359779488578115e-12,0.288944428463021,2128.1683704052016,17.402876421806848,-0.3271,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-605N,Solarspace Technology Co Ltd,Mono-c-Si,0,605.0,570.6,2.68,,,66.0,15.8,48.78,14.91,40.61,0.0078684,-0.11326715999999999,43.2,2.0208784776515167,15.809029315074223,3.914002206516903e-10,0.14987381260946347,1138.5301315497334,53.29414685198076,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-605N,Solarspace Technology Co Ltd,Mono-c-Si,0,605.0,573.6,2.68,,,66.0,15.8,48.78,14.91,40.61,0.006004,-0.11316960000000001,44.64,1.6603259864628837,15.818467577195488,2.701127375575227e-12,0.19396615549265556,165.94842003042257,1.424207081712938,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-610N,Solarspace Technology Co Ltd,Mono-c-Si,0,610.0,575.4,2.68,,,66.0,15.86,48.98,14.98,40.75,0.007898279999999999,-0.11373155999999998,43.2,1.7940220683776664,15.872622477475222,2.1755055204895694e-11,0.17679800330610562,222.14468973182096,20.01645237842318,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-610N,Solarspace Technology Co Ltd,Mono-c-Si,0,610.0,578.5,2.68,,,66.0,15.86,48.98,14.98,40.75,0.0060268,-0.1136336,44.64,1.6659727833297335,15.877580768708397,2.659379767825049e-12,0.196050677078616,176.86164869071587,1.2568575807761215,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-615N,Solarspace Technology Co Ltd,Mono-c-Si,0,615.0,580.3,2.68,,,66.0,15.92,49.18,15.05,40.89,0.00792816,-0.11419596,43.2,1.8000502522181379,15.931761056593183,2.143548408707404e-11,0.17890821716903152,242.17372030708037,19.830525108096207,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-615N,Solarspace Technology Co Ltd,Mono-c-Si,0,615.0,583.3,2.68,,,66.0,15.92,49.18,15.05,40.89,0.0060496000000000005,-0.11409760000000001,44.64,1.6716230057118802,15.936668089111217,2.6187353225274472e-12,0.19811485075652002,189.22315593136628,1.0913572012593726,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-620N,Solarspace Technology Co Ltd,Mono-c-Si,0,620.0,585.1,2.68,,,66.0,15.98,49.38,15.12,41.03,0.00795804,-0.11466036,43.2,1.806081963796934,15.990873530281812,2.1124011900547467e-11,0.18099790084648223,265.9988423387332,19.64660291196695,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SSA-66HD-620N,Solarspace Technology Co Ltd,Mono-c-Si,0,620.0,588.2,2.68,,,66.0,15.98,49.38,15.12,41.03,0.0060723999999999995,-0.11456160000000001,44.64,1.6772766082763353,15.995729889343135,2.579156734185591e-12,0.20015897436211488,203.34157088883362,0.9276769821326902,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SHA-66HD-625N,Solarspace Technology Co Ltd,Mono-c-Si,0,625.0,590.0,2.68,,,66.0,16.04,49.58,15.19,41.17,0.007987919999999999,-0.11512475999999999,43.2,1.812117191410166,16.049960274869203,2.0820385620444023e-11,0.1830673491707674,294.811171275723,19.46465998162062,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +Solarspace Technology Co Ltd SS9-66HD-675N,Solarspace Technology Co Ltd,Mono-c-Si,0,675.0,638.5,3.08,,,66.0,18.13,47.3,17.1,39.5,0.006708099999999999,-0.108317,45.44,1.603758745943084,18.151502647500728,2.763992744875369e-12,0.15698191708907053,132.35961564859704,1.807511728205632,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-680N,Solarspace Technology Co Ltd,Mono-c-Si,0,680.0,643.3,3.08,,,66.0,18.17,47.5,17.14,39.7,0.0067229,-0.10877500000000001,45.44,1.6110629940337677,18.19114247391084,2.7969656730666332e-12,0.1551191960223129,133.3105957889941,1.8889362580048505,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-685N,Solarspace Technology Co Ltd,Mono-c-Si,0,685.0,648.1,3.08,,,66.0,18.2,47.6,17.18,39.9,0.0067339999999999995,-0.10900400000000002,45.44,1.616143342243546,18.219498086708132,2.8907767254367292e-12,0.14752345440350342,137.70206851761222,2.15256343035899,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-690N,Solarspace Technology Co Ltd,Mono-c-Si,0,690.0,653.0,3.08,,,66.0,18.24,47.8,17.21,40.1,0.006748799999999999,-0.109462,45.44,1.6238631562808716,18.259869142969055,2.9446181811720758e-12,0.14567161567925876,133.72747256862263,2.2930489534068164,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-695N,Solarspace Technology Co Ltd,Mono-c-Si,0,695.0,657.8,3.08,,,66.0,18.28,48.0,17.25,40.3,0.006763600000000001,-0.10992,45.44,1.6311641193418625,18.29952239865695,2.978421628671302e-12,0.14384884118625127,134.69435106731254,2.3712187641663536,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-700N,Solarspace Technology Co Ltd,Mono-c-Si,0,700.0,662.7,3.08,,,66.0,18.32,48.2,17.29,40.5,0.0067783999999999995,-0.11037800000000002,45.44,1.638464330440265,18.339179602381467,3.012312249818183e-12,0.1420349110692532,135.66910931080582,2.448542504576908,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-705N,Solarspace Technology Co Ltd,Mono-c-Si,0,705.0,667.5,3.08,,,66.0,18.36,48.4,17.33,40.7,0.006793199999999999,-0.110836,45.44,1.6457637746258693,18.378840724382737,3.046287647384856e-12,0.14022973597072222,136.65174977851862,2.5250676182720064,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-710N,Solarspace Technology Co Ltd,Mono-c-Si,0,710.0,672.4,3.08,,,66.0,18.4,48.6,17.36,40.9,0.006808,-0.11129400000000002,45.44,1.6534876440827613,18.419172018949688,3.101641172073312e-12,0.13840603571177437,132.83270088947205,2.662350239871683,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solarspace Technology Co Ltd SS9-66HD-715N,Solarspace Technology Co Ltd,Mono-c-Si,0,715.0,677.2,3.08,,,66.0,18.44,48.8,17.4,41.1,0.0068228,-0.111752,45.44,1.6607867145639987,18.458830144972005,3.1359759149725654e-12,0.13661688674172914,133.78629831093636,2.7373403471458424,-0.284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Solartech Energy ASC-6P-36-130,Solartech Energy,Multi-c-Si,0,130.0,114.7,1.010848,1.019,0.992,36.0,8.42,21.69,7.92,16.41,0.005052,-0.078084,46.7,0.9190639705527304,8.45245924990926,4.759809049302775e-10,0.34583678223696224,999999.951915509,4.009560418688984,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-36-135,Solartech Energy,Multi-c-Si,0,135.0,119.2,1.010848,1.019,0.992,36.0,8.48,21.9,7.98,16.92,0.005088,-0.07884,46.7,0.9385162380726451,8.493954520468602,6.236989120101484e-10,0.29416697818821896,999999.9550816037,6.2669037324773385,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-36-140,Solartech Energy,Multi-c-Si,0,140.0,123.7,1.010848,1.019,0.992,36.0,8.53,22.15,8.03,17.43,0.005118,-0.07973999999999999,46.7,0.9587444888278004,8.530144647174621,7.894361640108497e-10,0.24883985191560248,14675.00739879943,8.27858220171185,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-36-145,Solartech Energy,Multi-c-Si,0,145.0,128.3,1.010848,1.019,0.992,36.0,8.6,22.37,8.1,17.9,0.00516,-0.080532,46.7,0.9776890982440002,8.601284070691177,9.928276329174831e-10,0.20551237976938086,1376.4136605546717,10.243895075493606,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-36-150,Solartech Energy,Multi-c-Si,0,150.0,132.8,1.010848,1.019,0.992,36.0,8.63,22.51,8.13,18.45,0.005178,-0.08103600000000001,46.7,0.9978455619476222,8.632182088035302,1.370956248368346e-09,0.14201697134380184,561.6676748239704,13.152063821512272,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-48-175,Solartech Energy,Multi-c-Si,0,175.0,154.5,1.325312,1.336,0.992,48.0,8.42,29.01,7.92,22.1,0.005052,-0.104436,46.7,1.2338187493568245,8.444891173063064,5.191597989582136e-10,0.4396767889451679,999999.9670202956,4.74996185400939,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-48-180,Solartech Energy,Multi-c-Si,0,180.0,159.0,1.325312,1.336,0.992,48.0,8.48,29.2,7.98,22.56,0.005088,-0.10511999999999999,46.7,1.25135535203142,8.493960745391172,6.237031123285393e-10,0.39222246782182896,999999.9680880794,6.266958715194018,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-48-185,Solartech Energy,Multi-c-Si,0,185.0,163.5,1.325312,1.336,0.992,48.0,8.53,29.49,8.03,23.04,0.005118,-0.106164,46.7,1.2714226152662487,8.535878124698488,7.211197536932541e-10,0.35581973150690155,999999.9687956444,7.480698542133426,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-48-190,Solartech Energy,Multi-c-Si,0,190.0,168.1,1.325312,1.336,0.992,48.0,8.57,29.73,8.07,23.54,0.005142,-0.107028,46.7,1.291390377084558,8.570538437285814,8.600167994852971e-10,0.3109276771228567,4948.913230253128,8.993547292474538,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-48-195,Solartech Energy,Multi-c-Si,0,195.0,172.7,1.325312,1.336,0.992,48.0,8.6,29.92,8.1,24.07,0.00516,-0.107712,46.7,1.3118394694045028,8.601647107515529,1.0670999826392416e-09,0.2559551921406603,1336.416015188975,10.894097233543796,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-48-200,Solartech Energy,Multi-c-Si,0,200.0,177.2,1.325312,1.336,0.992,48.0,8.63,30.12,8.13,24.6,0.005178,-0.108432,46.7,1.3323767314625476,8.632117859845438,1.307746594024798e-09,0.20279730596032133,826.3737049380172,12.71671090962342,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-54-200,Solartech Energy,Multi-c-Si,0,200.0,176.6,1.4830400000000001,1.495,0.992,54.0,8.42,32.8,7.92,25.25,0.005052,-0.11807999999999998,46.7,1.4029185397110302,8.433821496732536,5.919576244427773e-10,0.4576236213120663,999999.9724356463,5.879157634984293,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-54-205,Solartech Energy,Multi-c-Si,0,205.0,181.2,1.4830400000000001,1.495,0.992,54.0,8.47,33.01,7.97,25.72,0.005082000000000001,-0.118836,46.7,1.4211169248408386,8.47479583960076,6.922211241821569e-10,0.4117167559188255,999999.973074937,7.187222861826163,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-54-210,Solartech Energy,Multi-c-Si,0,210.0,185.7,1.4830400000000001,1.495,0.992,54.0,8.5,33.23,8.0,26.25,0.0051,-0.11962799999999998,46.7,1.4418060931334313,8.500808904866181,8.310294630776457e-10,0.3595468592147186,3778.1584892879146,8.763908915383174,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-54-215,Solartech Energy,Multi-c-Si,0,215.0,190.3,1.4830400000000001,1.495,0.992,54.0,8.52,33.44,8.02,26.81,0.005111999999999999,-0.12038399999999999,46.7,1.463652755268754,8.521903951766664,1.0161814961240068e-09,0.3023437464881,1352.9625027921966,10.539014410772621,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-54-220,Solartech Energy,Multi-c-Si,0,220.0,194.8,1.4830400000000001,1.495,0.992,54.0,8.55,33.66,8.05,27.33,0.00513,-0.12117599999999998,46.7,1.4842411950266843,8.552324574623794,1.2055873394940598e-09,0.25247338528555685,928.6219158997501,12.05785712347082,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-220,Solartech Energy,Multi-c-Si,0,220.0,197.6,1.6397760000000001,1.653,0.992,60.0,8.46,36.26,7.96,27.64,0.0043146,-0.1200206,45.9,1.4563573199876347,8.461085092683454,1.3015919896753738e-10,0.5657766086064154,999999.9755835012,2.0364921956594393,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-54-225,Solartech Energy,Multi-c-Si,0,225.0,199.4,1.4830400000000001,1.495,0.992,54.0,8.6,33.8,8.1,27.78,0.00516,-0.12167999999999998,46.7,1.5009507907185795,8.602322014864646,1.4204774580281692e-09,0.20277461666414157,751.0132998450268,13.513577573691977,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-225,Solartech Energy,Multi-c-Si,0,225.0,202.2,1.6397760000000001,1.653,0.992,60.0,8.48,36.4,7.98,28.2,0.0043248,-0.12048400000000001,45.9,1.4753252361219225,8.482215012614043,1.6307634018854303e-10,0.49908384482193674,1910.7052275612414,3.893693656158151,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-225-3BB,Solartech Energy,Multi-c-Si,0,225.0,202.2,1.6397760000000001,1.653,0.992,60.0,8.48,36.4,7.98,28.2,0.0043248,-0.12048400000000001,45.9,1.4753252361219225,8.482215012614043,1.6307634018854303e-10,0.49908384482193674,1910.7052275612414,3.893693656158151,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-230-3BB,Solartech Energy,Mono-c-Si,0,230.0,208.1,1.6397760000000001,1.653,0.992,60.0,8.5,36.2,8.0,28.8,0.00637415,-0.11728800000000002,45.6,1.4876912966278697,8.504503256054978,2.287704672994993e-10,0.3838303517464133,724.4889630269051,8.794169252016749,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-54-230,Solartech Energy,Multi-c-Si,0,230.0,204.0,1.4830400000000001,1.495,0.992,54.0,8.66,34.02,8.16,28.19,0.005195999999999999,-0.12247200000000001,46.7,1.5177023513835073,8.662098393334126,1.5858626748851989e-09,0.1694521510494714,699.3242922139076,14.473554262029387,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-230,Solartech Energy,Multi-c-Si,0,230.0,206.8,1.6397760000000001,1.653,0.992,60.0,8.5,36.68,8.0,28.75,0.004335,-0.12141080000000001,45.9,1.4964574346533512,8.50336233963631,1.9180546348004985e-10,0.4523372906922447,1143.510152034017,5.245203706161813,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-230-3BB,Solartech Energy,Multi-c-Si,0,230.0,206.8,1.6397760000000001,1.653,0.992,60.0,8.5,36.68,8.0,28.75,0.004335,-0.12141080000000001,45.9,1.4964574346533512,8.50336233963631,1.9180546348004985e-10,0.4523372906922447,1143.510152034017,5.245203706161813,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-235-3BB,Solartech Energy,Mono-c-Si,0,235.0,212.8,1.6397760000000001,1.653,0.992,60.0,8.6,36.5,8.0,29.4,0.00644914,-0.11826,45.6,1.519871231814827,8.614910329214432,3.131771872351029e-10,0.32937765700383687,189.97891791680138,11.537077156218835,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-235,Solartech Energy,Multi-c-Si,0,235.0,211.4,1.6397760000000001,1.653,0.992,60.0,8.52,36.98,8.02,29.3,0.0043452,-0.1224038,45.9,1.5178962243250576,8.52406593261838,2.227759347651711e-10,0.40848248546401794,855.9592104614187,6.5062144073999475,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-235-3BB,Solartech Energy,Multi-c-Si,0,235.0,211.4,1.6397760000000001,1.653,0.992,60.0,8.52,36.98,8.02,29.3,0.0043452,-0.1224038,45.9,1.5178962243250576,8.52406593261838,2.227759347651711e-10,0.40848248546401794,855.9592104614187,6.5062144073999475,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-240-3BB,Solartech Energy,Mono-c-Si,0,240.0,217.4,1.6397760000000001,1.653,0.992,60.0,8.6,36.8,8.1,29.7,0.00644914,-0.119232,45.6,1.5241726191431932,8.604378951580925,2.793045416794327e-10,0.32406006124281433,636.43486485192,10.465196711266637,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-240,Solartech Energy,Multi-c-Si,0,240.0,216.0,1.6397760000000001,1.653,0.992,60.0,8.55,37.16,8.05,29.81,0.0043605,-0.1229996,45.9,1.535927724560689,8.554456475998048,2.6433845561174063e-10,0.3551086940285755,681.2962641112626,7.958819119647454,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-240-3BB,Solartech Energy,Multi-c-Si,0,240.0,216.0,1.6397760000000001,1.653,0.992,60.0,8.55,37.16,8.05,29.81,0.0043605,-0.1229996,45.9,1.535927724560689,8.554456475998048,2.6433845561174063e-10,0.3551086940285755,681.2962641112626,7.958819119647454,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-245-3BB,Solartech Energy,Mono-c-Si,0,245.0,222.0,1.6397760000000001,1.653,0.992,60.0,8.7,37.1,8.1,30.3,0.0065241299999999995,-0.120204,45.6,1.5565244982669681,8.71246271932672,3.7909716429709195e-10,0.2702542588585858,188.65965307996635,13.174506747050728,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-245,Solartech Energy,Multi-c-Si,0,245.0,220.6,1.6397760000000001,1.653,0.992,60.0,8.58,37.4,8.08,30.32,0.0043758,-0.123794,45.9,1.5549734024117108,8.584489725990034,3.054342445727736e-10,0.3098299437335797,592.0944149216498,9.196930520455401,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-245-3BB,Solartech Energy,Multi-c-Si,0,245.0,220.6,1.6397760000000001,1.653,0.992,60.0,8.58,37.4,8.08,30.32,0.0043758,-0.123794,45.9,1.5549734024117108,8.584489725990034,3.054342445727736e-10,0.3098299437335797,592.0944149216498,9.196930520455401,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-250-3BB,Solartech Energy,Mono-c-Si,0,250.0,226.7,1.6397760000000001,1.653,0.992,60.0,8.7,37.4,8.2,30.6,0.0065241299999999995,-0.121176,45.6,1.5605170532569754,8.703980570874341,3.3729746415534876e-10,0.2659089551653577,581.1750751856598,12.06438613139859,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-250,Solartech Energy,Multi-c-Si,0,250.0,225.3,1.6397760000000001,1.653,0.992,60.0,8.61,37.65,8.11,30.83,0.004391099999999999,-0.12462150000000001,45.9,1.5741532876158044,8.61430745709777,3.5022594720328094e-10,0.2662234276998279,532.1432584545946,10.3813508475736,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-250-3BB,Solartech Energy,Multi-c-Si,0,250.0,225.3,1.6397760000000001,1.653,0.992,60.0,8.61,37.65,8.11,30.83,0.004391099999999999,-0.12462150000000001,45.9,1.5741532876158044,8.61430745709777,3.5022594720328094e-10,0.2662234276998279,532.1432584545946,10.3813508475736,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-255-3BB,Solartech Energy,Mono-c-Si,0,255.0,231.4,1.6397760000000001,1.653,0.992,60.0,8.8,37.9,8.2,31.1,0.006599120000000001,-0.122796,45.6,1.5936912551727582,8.81132244844361,4.0487632856096716e-10,0.25197330626571524,195.83797142714687,13.673526631057422,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-255,Solartech Energy,Multi-c-Si,0,255.0,229.8,1.6397760000000001,1.653,0.992,60.0,8.66,38.2,8.16,31.25,0.006410997999999999,-0.12949800000000003,46.5,1.6120762497607393,8.6637305290337,4.4006727144763747e-10,0.2688719997938197,624.156088020197,9.442969749554285,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-255-3BB,Solartech Energy,Multi-c-Si,0,255.0,229.8,1.6397760000000001,1.653,0.992,60.0,8.66,38.2,8.16,31.25,0.006410997999999999,-0.12949800000000003,46.5,1.6120762497607393,8.6637305290337,4.4006727144763747e-10,0.2688719997938197,624.156088020197,9.442969749554285,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60A-255-3BB,Solartech Energy,Multi-c-Si,0,255.0,229.8,1.6397760000000001,1.653,0.992,60.0,8.66,38.2,8.16,31.25,0.006410997999999999,-0.12949800000000003,46.5,1.6120762497607393,8.6637305290337,4.4006727144763747e-10,0.2688719997938197,624.156088020197,9.442969749554285,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-260-3BB,Solartech Energy,Mono-c-Si,0,260.0,236.0,1.6397760000000001,1.653,0.992,60.0,8.8,38.2,8.3,31.4,0.006599120000000001,-0.12376800000000003,45.6,1.597508716636231,8.803537363526575,3.6028088516954554e-10,0.24799472650081464,616.9437167743549,12.559620388646511,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-260-3BB,Solartech Energy,Multi-c-Si,0,260.0,234.4,1.6397760000000001,1.653,0.992,60.0,8.7,38.28,8.2,31.71,0.006440609999999999,-0.12976920000000003,46.5,1.6268959159161476,8.703373957703175,5.217387582470234e-10,0.21159005485297644,545.6008157314199,10.926983115523965,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60A-260-3BB,Solartech Energy,Multi-c-Si,0,260.0,234.4,1.6397760000000001,1.653,0.992,60.0,8.7,38.28,8.2,31.71,0.006440609999999999,-0.12976920000000003,46.5,1.6268959159161476,8.703373957703175,5.217387582470234e-10,0.21159005485297644,545.6008157314199,10.926983115523965,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-265-3BB,Solartech Energy,Mono-c-Si,0,265.0,240.7,1.6397760000000001,1.653,0.992,60.0,8.9,38.5,8.3,32.0,0.0066741100000000005,-0.12474,45.6,1.6301339298072552,8.908888524931962,4.820492175904912e-10,0.19542020772435142,195.6725133000472,15.19074806111262,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60A-265-3BB,Solartech Energy,Mono-c-Si,0,265.0,240.7,1.6397760000000001,1.653,0.992,60.0,8.9,38.5,8.3,32.0,0.0066741100000000005,-0.12474,45.6,1.6301339298072552,8.908888524931962,4.820492175904912e-10,0.19542020772435142,195.6725133000472,15.19074806111262,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-265-3BB,Solartech Energy,Multi-c-Si,0,265.0,239.1,1.6397760000000001,1.653,0.992,60.0,8.73,38.4,8.23,32.2,0.006462819,-0.13017600000000001,46.5,1.6432916932710466,8.732792396813355,6.148055014121576e-10,0.15580600219410184,487.1036875562398,12.387318652883184,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60A-265-3BB,Solartech Energy,Multi-c-Si,0,265.0,239.1,1.6397760000000001,1.653,0.992,60.0,8.73,38.4,8.23,32.2,0.006462819,-0.13017600000000001,46.5,1.6432916932710466,8.732792396813355,6.148055014121576e-10,0.15580600219410184,487.1036875562398,12.387318652883184,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-265,Solartech Energy,Multi-c-Si,0,265.0,234.1,1.94432,1.96,0.992,72.0,8.05,43.5,7.47,35.48,0.00483,-0.1566,46.7,1.939047251217845,8.060944416916163,1.4237433562161667e-09,0.3184372851285738,234.22180297713808,14.199354045894495,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-270-3BB,Solartech Energy,Mono-c-Si,0,270.0,245.3,1.6397760000000001,1.653,0.992,60.0,8.9,38.8,8.4,32.2,0.0066741100000000005,-0.125712,45.6,1.6308122735547514,8.90303569253132,4.1090274998977403e-10,0.2062874917999665,604.7908922398233,13.662735324919586,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60A-270-3BB,Solartech Energy,Mono-c-Si,0,270.0,245.3,1.6397760000000001,1.653,0.992,60.0,8.9,38.8,8.4,32.2,0.0066741100000000005,-0.125712,45.6,1.6308122735547514,8.90303569253132,4.1090274998977403e-10,0.2062874917999665,604.7908922398233,13.662735324919586,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60-270-3BB,Solartech Energy,Multi-c-Si,0,270.0,243.7,1.6397760000000001,1.653,0.992,60.0,8.8,38.6,8.32,32.46,0.00651464,-0.13085400000000003,46.5,1.6519165071498585,8.80165778692079,6.22269193236766e-10,0.14310194706140572,759.625775034384,12.414743097311032,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-60A-270-3BB,Solartech Energy,Multi-c-Si,0,270.0,243.7,1.6397760000000001,1.653,0.992,60.0,8.8,38.6,8.32,32.46,0.00651464,-0.13085400000000003,46.5,1.6519165071498585,8.80165778692079,6.22269193236766e-10,0.14310194706140572,759.625775034384,12.414743097311032,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-270,Solartech Energy,Multi-c-Si,0,270.0,238.6,1.94432,1.96,0.992,72.0,8.09,43.85,7.59,35.55,0.004854,-0.15786,46.7,1.9355899698582588,8.094541819320861,1.1633126705845223e-09,0.3554629217034769,633.1598311234839,12.248972816336597,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60-275-3BB,Solartech Energy,Mono-c-Si,0,275.0,250.0,1.6397760000000001,1.653,0.992,60.0,9.0,39.1,8.4,32.8,0.0067491,-0.12668400000000002,45.6,1.663554183423682,9.00699861010018,5.462141092194915e-10,0.15431234230911994,198.44100510299563,16.26062281334929,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-60A-275-3BB,Solartech Energy,Mono-c-Si,0,275.0,250.0,1.6397760000000001,1.653,0.992,60.0,9.0,39.1,8.4,32.8,0.0067491,-0.12668400000000002,45.6,1.663554183423682,9.00699861010018,5.462141092194915e-10,0.15431234230911994,198.44100510299563,16.26062281334929,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-275,Solartech Energy,Multi-c-Si,0,275.0,243.2,1.94432,1.96,0.992,72.0,8.2,44.0,7.7,35.7,0.004919999999999999,-0.15839999999999999,46.7,1.942189269203606,8.204001342748503,1.1799647606813317e-09,0.3476395104905964,712.4225472450066,12.252566749087405,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-280,Solartech Energy,Multi-c-Si,0,280.0,251.8,1.94432,1.96,0.992,72.0,8.33,44.15,7.83,35.78,0.0061666989999999994,-0.1496685,46.5,1.8554886472986991,8.335331099985076,3.8303909869322134e-10,0.37354854440954327,583.6807330699555,8.564698957073642,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-280-3BB,Solartech Energy,Multi-c-Si,0,280.0,251.8,1.94432,1.96,0.992,72.0,8.33,44.15,7.83,35.78,0.0061666989999999994,-0.1496685,46.5,1.8554886472986991,8.335331099985076,3.8303909869322134e-10,0.37354854440954327,583.6807330699555,8.564698957073642,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72-285-3BB,Solartech Energy,Mono-c-Si,0,285.0,258.2,1.94432,1.96,0.992,72.0,8.6,44.1,8.0,35.7,0.00644914,-0.142884,45.6,1.8416558502136393,8.614234850810233,3.3546875933375367e-10,0.3716181656235093,224.51352801382865,12.162554023860027,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-285,Solartech Energy,Multi-c-Si,0,285.0,256.4,1.94432,1.96,0.992,72.0,8.41,44.32,7.91,36.02,0.006225923,-0.1502448,46.5,1.8650991423941972,8.414908133902399,3.9923406925023327e-10,0.3562195584002591,610.3760648276161,8.844369902383427,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-285-3BB,Solartech Energy,Multi-c-Si,0,285.0,256.4,1.94432,1.96,0.992,72.0,8.41,44.32,7.91,36.02,0.006225923,-0.1502448,46.5,1.8650991423941972,8.414908133902399,3.9923406925023327e-10,0.3562195584002591,610.3760648276161,8.844369902383427,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72-290-3BB,Solartech Energy,Mono-c-Si,0,290.0,262.8,1.94432,1.96,0.992,72.0,8.6,44.4,8.0,36.3,0.00644914,-0.143856,45.6,1.8647841867656856,8.612731480518297,3.839491331546145e-10,0.32146430555301553,217.14625469754083,13.401066976631972,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-290,Solartech Energy,Multi-c-Si,0,290.0,261.0,1.94432,1.96,0.992,72.0,8.52,44.46,8.02,36.16,0.006307356,-0.1507194,46.5,1.870964850326801,8.524377090480394,4.046824917364473e-10,0.34896162193645136,679.2535141924103,8.846763813208137,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-290-3BB,Solartech Energy,Multi-c-Si,0,290.0,261.0,1.94432,1.96,0.992,72.0,8.52,44.46,8.02,36.16,0.006307356,-0.1507194,46.5,1.870964850326801,8.524377090480394,4.046824917364473e-10,0.34896162193645136,679.2535141924103,8.846763813208137,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72-295-3BB,Solartech Energy,Mono-c-Si,0,295.0,267.5,1.94432,1.96,0.992,72.0,8.7,44.7,8.1,36.5,0.0065241299999999995,-0.144828,45.6,1.8751740831566663,8.712491849477914,3.7810833750870327e-10,0.3266364772158893,227.48734375455703,13.150458490208049,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-295,Solartech Energy,Multi-c-Si,0,295.0,265.7,1.94432,1.96,0.992,72.0,8.58,44.68,8.08,36.38,0.006351774,-0.15146520000000002,46.5,1.881014662737834,8.584093975788464,4.1178949939320453e-10,0.3422884603050181,717.3555129193574,8.93741071694078,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-295-3BB,Solartech Energy,Multi-c-Si,0,295.0,265.7,1.94432,1.96,0.992,72.0,8.58,44.68,8.08,36.38,0.006351774,-0.15146520000000002,46.5,1.881014662737834,8.584093975788464,4.1178949939320453e-10,0.3422884603050181,717.3555129193574,8.93741071694078,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72-300-3BB,Solartech Energy,Mono-c-Si,0,300.0,272.1,1.94432,1.96,0.992,72.0,8.7,45.0,8.1,37.1,0.0065241299999999995,-0.1458,45.6,1.8982240800401302,8.71093493347107,4.307501320966823e-10,0.2771867338251107,220.53401915289814,14.357197059027934,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-300,Solartech Energy,Multi-c-Si,0,300.0,270.3,1.94432,1.96,0.992,72.0,8.62,44.75,8.23,36.45,0.006381386,-0.15170250000000002,46.5,1.8858579043469679,8.620002579702545,4.2660049036359604e-10,0.29912457395688047,999999.626282473,9.188757000516231,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72-300-3BB,Solartech Energy,Multi-c-Si,0,300.0,270.3,1.94432,1.96,0.992,72.0,8.62,44.75,8.23,36.45,0.006381386,-0.15170250000000002,46.5,1.8858579043469679,8.620002579702545,4.2660049036359604e-10,0.29912457395688047,999999.626282473,9.188757000516231,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-305-3BB,Solartech Energy,Mono-c-Si,0,305.0,276.8,1.94432,1.96,0.992,72.0,8.8,45.4,8.2,37.2,0.006599120000000001,-0.147096,45.6,1.9074651675672125,8.811544444096878,3.969428338439765e-10,0.3096451312280449,236.03366516251896,13.490613378121346,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-305,Solartech Energy,Multi-c-Si,0,305.0,274.9,1.94432,1.96,0.992,72.0,8.68,44.83,8.35,36.53,0.006425804,-0.1519737,46.5,1.897236764221274,8.680183465877597,4.746244711485332e-10,0.24904897377534088,11782.882787809422,10.076827948408193,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72-305-3BB,Solartech Energy,Multi-c-Si,0,305.0,274.9,1.94432,1.96,0.992,72.0,8.68,44.83,8.35,36.53,0.006425804,-0.1519737,46.5,1.897236764221274,8.680183465877597,4.746244711485332e-10,0.24904897377534088,11782.882787809422,10.076827948408193,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72B-305-3BB,Solartech Energy,Multi-c-Si,0,305.0,274.9,1.94432,1.96,0.992,72.0,8.68,44.83,8.35,36.53,0.006425804,-0.1519737,46.5,1.897236764221274,8.680183465877597,4.746244711485332e-10,0.24904897377534088,11782.882787809422,10.076827948408193,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72C-305-3BB,Solartech Energy,Multi-c-Si,0,305.0,274.9,1.94432,1.96,0.992,72.0,8.68,44.83,8.35,36.53,0.006425804,-0.1519737,46.5,1.897236764221274,8.680183465877597,4.746244711485332e-10,0.24904897377534088,11782.882787809422,10.076827948408193,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-310-3BB,Solartech Energy,Mono-c-Si,0,310.0,281.4,1.94432,1.96,0.992,72.0,8.8,45.7,8.2,37.9,0.006599120000000001,-0.148068,45.6,1.9333973124194306,8.809576011540477,4.671003801546245e-10,0.2464940080479665,226.5188888387166,15.004154462177734,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-310-3BB,Solartech Energy,Multi-c-Si,0,310.0,279.6,1.94432,1.96,0.992,72.0,8.7,45.18,8.31,37.3,0.006440609999999999,-0.1531602,46.5,1.9166898568777233,8.70000202009113,5.039366015774673e-10,0.2320861371462793,999999.8267059064,10.591371401801801,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72B-310-3BB,Solartech Energy,Multi-c-Si,0,310.0,279.6,1.94432,1.96,0.992,72.0,8.7,45.18,8.31,37.3,0.006440609999999999,-0.1531602,46.5,1.9166898568777233,8.70000202009113,5.039366015774673e-10,0.2320861371462793,999999.8267059064,10.591371401801801,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72C-310-3BB,Solartech Energy,Multi-c-Si,0,310.0,279.6,1.94432,1.96,0.992,72.0,8.7,45.18,8.31,37.3,0.006440609999999999,-0.1531602,46.5,1.9166898568777233,8.70000202009113,5.039366015774673e-10,0.2320861371462793,999999.8267059064,10.591371401801801,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-315-3BB,Solartech Energy,Mono-c-Si,0,315.0,286.1,1.94432,1.96,0.992,72.0,8.9,46.0,8.3,38.0,0.0066741100000000005,-0.14904,45.6,1.9408653436277987,8.909905318397183,4.439129932656708e-10,0.26660805970794504,239.54928965137273,14.420370698450357,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-315-3BB,Solartech Energy,Multi-c-Si,0,315.0,284.2,1.94432,1.96,0.992,72.0,8.72,45.32,8.38,37.58,0.006455416000000001,-0.15363480000000002,46.5,1.9331034745642663,8.720125777384238,5.736704714282562e-10,0.17316717422808328,12005.543790136877,11.741318174052711,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72B-315-3BB,Solartech Energy,Multi-c-Si,0,315.0,284.2,1.94432,1.96,0.992,72.0,8.72,45.32,8.38,37.58,0.006455416000000001,-0.15363480000000002,46.5,1.9331034745642663,8.720125777384238,5.736704714282562e-10,0.17316717422808328,12005.543790136877,11.741318174052711,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72C-315-3BB,Solartech Energy,Multi-c-Si,0,315.0,284.2,1.94432,1.96,0.992,72.0,8.72,45.32,8.38,37.58,0.006455416000000001,-0.15363480000000002,46.5,1.9331034745642663,8.720125777384238,5.736704714282562e-10,0.17316717422808328,12005.543790136877,11.741318174052711,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-320-3BB,Solartech Energy,Mono-c-Si,0,320.0,290.8,1.94432,1.96,0.992,72.0,8.9,46.3,8.3,38.6,0.0066741100000000005,-0.150012,45.6,1.9637983907594179,8.908357779811437,5.020292257865514e-10,0.21846433187258998,232.63747012731127,15.572367491814127,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72B-320-3BB,Solartech Energy,Mono-c-Si,0,320.0,290.8,1.94432,1.96,0.992,72.0,8.9,46.3,8.3,38.6,0.0066741100000000005,-0.150012,45.6,1.9637983907594179,8.908357779811437,5.020292257865514e-10,0.21846433187258998,232.63747012731127,15.572367491814127,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72C-320-3BB,Solartech Energy,Mono-c-Si,0,320.0,290.8,1.94432,1.96,0.992,72.0,8.9,46.3,8.3,38.6,0.0066741100000000005,-0.150012,45.6,1.9637983907594179,8.908357779811437,5.020292257865514e-10,0.21846433187258998,232.63747012731127,15.572367491814127,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-320-3BB,Solartech Energy,Multi-c-Si,0,320.0,288.8,1.94432,1.96,0.992,72.0,8.76,45.5,8.42,38.0,0.0064850279999999995,-0.15424500000000002,46.5,1.9469197918211354,8.760001562228103,6.207706692755007e-10,0.13945148693373277,780374.6766010969,12.416482601461444,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72B-320-3BB,Solartech Energy,Multi-c-Si,0,320.0,288.8,1.94432,1.96,0.992,72.0,8.76,45.5,8.42,38.0,0.0064850279999999995,-0.15424500000000002,46.5,1.9469197918211354,8.760001562228103,6.207706692755007e-10,0.13945148693373277,780374.6766010969,12.416482601461444,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72C-320-3BB,Solartech Energy,Multi-c-Si,0,320.0,288.8,1.94432,1.96,0.992,72.0,8.76,45.5,8.42,38.0,0.0064850279999999995,-0.15424500000000002,46.5,1.9469197918211354,8.760001562228103,6.207706692755007e-10,0.13945148693373277,780374.6766010969,12.416482601461444,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-325-3BB,Solartech Energy,Mono-c-Si,0,325.0,295.4,1.94432,1.96,0.992,72.0,9.0,46.6,8.4,38.7,0.0067491,-0.150984,45.6,1.9712841042568943,9.008732864500507,4.77491516326465e-10,0.23865405694253775,245.9544338594871,14.994305075421789,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72B-325-3BB,Solartech Energy,Mono-c-Si,0,325.0,295.4,1.94432,1.96,0.992,72.0,9.0,46.6,8.4,38.7,0.0067491,-0.150984,45.6,1.9712841042568943,9.008732864500507,4.77491516326465e-10,0.23865405694253775,245.9544338594871,14.994305075421789,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72C-325-3BB,Solartech Energy,Mono-c-Si,0,325.0,295.4,1.94432,1.96,0.992,72.0,9.0,46.6,8.4,38.7,0.0067491,-0.150984,45.6,1.9712841042568943,9.008732864500507,4.77491516326465e-10,0.23865405694253775,245.9544338594871,14.994305075421789,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-325-3BB,Solartech Energy,Multi-c-Si,0,325.0,293.5,1.94432,1.96,0.992,72.0,8.78,45.65,8.48,38.32,0.0064998339999999995,-0.15475350000000002,46.5,1.9635355660933154,8.780058400283744,7.021831823267926e-10,0.08020739424628558,12058.581117101043,13.527991481205763,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72B-325-3BB,Solartech Energy,Multi-c-Si,0,325.0,293.5,1.94432,1.96,0.992,72.0,8.78,45.65,8.48,38.32,0.0064998339999999995,-0.15475350000000002,46.5,1.9635355660933154,8.780058400283744,7.021831823267926e-10,0.08020739424628558,12058.581117101043,13.527991481205763,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72C-325-3BB,Solartech Energy,Multi-c-Si,0,325.0,293.5,1.94432,1.96,0.992,72.0,8.78,45.65,8.48,38.32,0.0064998339999999995,-0.15475350000000002,46.5,1.9635355660933154,8.780058400283744,7.021831823267926e-10,0.08020739424628558,12058.581117101043,13.527991481205763,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-330-3BB,Solartech Energy,Mono-c-Si,0,330.0,300.1,1.94432,1.96,0.992,72.0,9.0,46.9,8.4,39.3,0.0067491,-0.151956,45.6,1.9941630633492413,9.007197553457527,5.382802922308501e-10,0.19113440831331865,238.9992462213748,16.12211800895707,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72B-330-3BB,Solartech Energy,Mono-c-Si,0,330.0,300.1,1.94432,1.96,0.992,72.0,9.0,46.9,8.4,39.3,0.0067491,-0.151956,45.6,1.9941630633492413,9.007197553457527,5.382802922308501e-10,0.19113440831331865,238.9992462213748,16.12211800895707,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72C-330-3BB,Solartech Energy,Mono-c-Si,0,330.0,300.1,1.94432,1.96,0.992,72.0,9.0,46.9,8.4,39.3,0.0067491,-0.151956,45.6,1.9941630633492413,9.007197553457527,5.382802922308501e-10,0.19113440831331865,238.9992462213748,16.12211800895707,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6P-72-330-3BB,Solartech Energy,Multi-c-Si,0,330.0,298.2,1.94432,1.96,0.992,72.0,8.82,45.8,8.54,38.62,0.0065294459999999995,-0.155262,46.5,1.9760160336568393,8.820000374552084,7.575490247351829e-10,0.042448125646069555,999999.9676426401,14.186934869326276,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72B-330-3BB,Solartech Energy,Multi-c-Si,0,330.0,298.2,1.94432,1.96,0.992,72.0,8.82,45.8,8.54,38.62,0.0065294459999999995,-0.155262,46.5,1.9760160336568393,8.820000374552084,7.575490247351829e-10,0.042448125646069555,999999.9676426401,14.186934869326276,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6P-72C-330-3BB,Solartech Energy,Multi-c-Si,0,330.0,298.2,1.94432,1.96,0.992,72.0,8.82,45.8,8.54,38.62,0.0065294459999999995,-0.155262,46.5,1.9760160336568393,8.820000374552084,7.575490247351829e-10,0.042448125646069555,999999.9676426401,14.186934869326276,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +Solartech Energy ASC-6M-72-335-3BB,Solartech Energy,Mono-c-Si,0,335.0,304.8,1.94432,1.96,0.992,72.0,9.1,47.2,8.5,39.5,0.00682409,-0.152928,45.6,2.004562542188957,9.107190751722202,5.299885807387185e-10,0.1975795083752177,250.03974041062892,15.868322640073682,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72B-335-3BB,Solartech Energy,Mono-c-Si,0,335.0,304.8,1.94432,1.96,0.992,72.0,9.1,47.2,8.5,39.5,0.00682409,-0.152928,45.6,2.004562542188957,9.107190751722202,5.299885807387185e-10,0.1975795083752177,250.03974041062892,15.868322640073682,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Energy ASC-6M-72C-335-3BB,Solartech Energy,Mono-c-Si,0,335.0,304.8,1.94432,1.96,0.992,72.0,9.1,47.2,8.5,39.5,0.00682409,-0.152928,45.6,2.004562542188957,9.107190751722202,5.299885807387185e-10,0.1975795083752177,250.03974041062892,15.868322640073682,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM190P,Solartech Power,Multi-c-Si,0,190.0,159.1,1.6301599999999998,1.64,0.994,60.0,7.6,35.6,6.7,28.5,0.0038852867830423943,-0.12959564032697546,49.7,1.7531477103938842,7.641710979794869,1.0667182350210997e-08,0.31959386934538997,58.23203579528173,34.19152096126081,-0.5948638931689779,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM195P,Solartech Power,Multi-c-Si,0,195.0,163.5,1.6301599999999998,1.64,0.994,60.0,7.6,35.6,6.85,28.5,0.0038852867830423943,-0.12959564032697546,49.7,1.728569879949874,7.627882198919405,8.214651987776818e-09,0.32514758312129594,88.62729771788581,31.225567195615124,-0.5948638931689779,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM200P,Solartech Power,Multi-c-Si,0,200.0,167.8,1.6301599999999998,1.64,0.994,60.0,7.7,36.5,7.0,28.6,0.0039364089775561105,-0.1328719346049046,49.7,1.7387145753465902,7.728414308617443,5.6697239504703235e-09,0.4389947404812957,118.96342739437243,27.072562336969167,-0.5948638931689779,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM205P,Solartech Power,Multi-c-Si,0,205.0,172.1,1.6301599999999998,1.64,0.994,60.0,8.07,37.1,7.12,28.8,0.004125561097256859,-0.13505613079019071,49.7,1.7885612247665732,8.134171882975712,7.359928589681546e-09,0.4697060379429994,59.068407144824285,29.436329782175584,-0.5948638931689779,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM210P,Solartech Power,Multi-c-Si,0,210.0,176.5,1.6301599999999998,1.64,0.994,60.0,8.12,38.1,7.14,29.4,0.004151122194513716,-0.13869645776566755,49.7,1.8332117215345696,8.192153819355184,7.0900060250654465e-09,0.5096816240763751,57.35827022794431,28.975148942624116,-0.5948638931689779,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM220P,Solartech Power,Multi-c-Si,0,220.0,196.2,1.60974,1.626,0.99,60.0,8.13,36.9,7.54,29.2,0.004691010000000001,-0.1310688,45.6,1.5938750234058672,8.145916240517668,7.033282963837463e-10,0.4152246913904084,212.0964324646159,9.235131243940446,-0.4883,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM225P,Solartech Power,Multi-c-Si,0,225.0,200.8,1.60974,1.626,0.99,60.0,8.27,37.08,7.67,29.34,0.00477179,-0.13170816,45.6,1.6015516604180249,8.286177417329172,7.144488984986333e-10,0.41056687072551307,209.8844983227853,9.222752895897285,-0.4883,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM230P,Solartech Power,Multi-c-Si,0,230.0,205.4,1.60974,1.626,0.99,60.0,8.39,37.2,7.8,29.49,0.0048410300000000005,-0.1321344,45.6,1.6064573187850824,8.40389361980465,7.238338431767113e-10,0.39755891154064515,240.07569725765083,9.203560727253269,-0.4883,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM235P,Solartech Power,Multi-c-Si,0,235.0,210.0,1.60974,1.626,0.99,60.0,8.45,37.26,7.93,29.63,0.00487565,-0.13234752,45.6,1.6039647617908221,8.454855271325052,6.848258910368958e-10,0.38144044812248035,663.8505878499203,8.620982316903582,-0.4883,N,2025.7.3,6/23/2025,4.0,first_pass +Solartech Power SPM240P,Solartech Power,Multi-c-Si,0,240.0,214.6,1.60974,1.626,0.99,60.0,8.57,37.38,8.06,29.77,0.00494489,-0.13277376000000002,45.6,1.608718381146955,8.572936904741983,6.920823392603269e-10,0.37073402685515056,1081.8176012708298,8.58275978130673,-0.4883,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-390,SOLEX ENERGY LTD,Mono-c-Si,0,390.0,363.0,1.95,,,54.0,13.15,38.23,12.54,31.13,0.0022881,-0.08712616999999999,48.51,1.2797358638550425,13.15411137921497,1.3919536156899124e-12,0.2463605056303871,787.9693145892547,-0.5279698338916694,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-390,SOLEX ENERGY LTD,Mono-c-Si,0,390.0,363.8,1.95,,,54.0,13.15,38.23,12.54,31.13,0.00172265,-0.08743200999999999,47.31,1.2833947589954537,13.153941147291631,1.5158957615874948e-12,0.2457061802707372,819.8212464545942,-0.1072895875636323,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-395,SOLEX ENERGY LTD,Mono-c-Si,0,395.0,367.7,1.95,,,54.0,13.24,38.4,12.63,31.3,0.00230376,-0.0875136,48.51,1.2858292442213715,13.243743788932521,1.4150559427659508e-12,0.24291289630640878,859.0673296644753,-0.4493657720850697,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-395,SOLEX ENERGY LTD,Mono-c-Si,0,395.0,368.6,1.95,,,54.0,13.24,38.4,12.63,31.3,0.0017344400000000003,-0.08782079999999999,47.31,1.2895051008257659,13.243575603669978,1.5409974285123548e-12,0.24225976225167786,897.0567109680853,-0.02886613005280038,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-400,SOLEX ENERGY LTD,Mono-c-Si,0,400.0,372.5,1.95,,,54.0,13.33,38.57,12.72,31.47,0.00231942,-0.08790102999999999,48.51,1.2919228238412759,13.333384944605124,1.4383491453305367e-12,0.23951439629779914,943.2139334569899,-0.3714219698875347,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-400,SOLEX ENERGY LTD,Mono-c-Si,0,400.0,373.4,1.95,,,54.0,13.33,38.57,12.72,31.47,0.00174623,-0.08820958999999999,47.31,1.2956156682390039,13.333218801376397,1.5663065372524337e-12,0.23886243327056736,989.1993572443088,0.048902903822231815,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-405,SOLEX ENERGY LTD,Mono-c-Si,0,405.0,377.3,1.95,,,54.0,13.42,38.74,12.8,31.64,0.0023350800000000002,-0.08828846,48.51,1.298435967167206,13.424117113823694,1.4746536159172168e-12,0.23620700310923004,769.9320761222617,-0.2177831484477689,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-405,SOLEX ENERGY LTD,Mono-c-Si,0,405.0,378.2,1.95,,,54.0,13.42,38.74,12.8,31.64,0.0017580200000000003,-0.08859838,47.31,1.3021326753527354,13.423950769647996,1.6052119168490415e-12,0.23555787450287585,800.1445202795052,0.19960388616982475,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-410,SOLEX ENERGY LTD,Mono-c-Si,0,410.0,382.1,1.95,,,54.0,13.5,38.99,12.88,31.85,0.002349,-0.08885821,48.51,1.3067663059748893,13.503754074572317,1.4822591549444326e-12,0.2357938166750703,847.9364160875285,-0.22577431105996754,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-410,SOLEX ENERGY LTD,Mono-c-Si,0,410.0,383.0,1.95,,,54.0,13.5,38.99,12.88,31.85,0.0017685,-0.08917013,47.31,1.3105018490435225,13.503587575511677,1.6140505687667073e-12,0.23514189849623385,884.8358463803187,0.19445794381811649,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-415,SOLEX ENERGY LTD,Mono-c-Si,0,415.0,386.9,1.95,,,54.0,13.58,39.16,12.96,32.02,0.0023629199999999997,-0.08924563999999999,48.51,1.3128788897340227,13.583449895264499,1.5055237176241732e-12,0.2326840803900117,915.92630610603,-0.14655730722711297,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-415,SOLEX ENERGY LTD,Mono-c-Si,0,415.0,387.8,1.95,,,54.0,13.58,39.16,12.96,32.02,0.00177898,-0.08955891999999999,47.31,1.3166315676548772,13.583285368247322,1.6393268574072213e-12,0.23203276891073352,959.1025360841145,0.273525256501268,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB54HM10-420,SOLEX ENERGY LTD,Mono-c-Si,0,420.0,391.7,1.95,,,54.0,13.66,39.31,13.04,32.21,0.00237684,-0.08958748999999999,48.51,1.3189847746917533,13.663232828798261,1.5519181165415344e-12,0.2263305120959433,956.3373182512263,0.05632606211693829,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB54HM10-420,SOLEX ENERGY LTD,Mono-c-Si,0,420.0,392.6,1.95,,,54.0,13.66,39.31,13.04,32.21,0.00178946,-0.08990197,47.31,1.3227547488435094,13.663072571049085,1.689720544577541e-12,0.22567921517294215,1003.3219887692225,0.4761631316238136,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-430,SOLEX ENERGY LTD,Mono-c-Si,0,430.0,400.1,2.17,,,60.0,13.18,41.33,12.57,34.23,0.0022933199999999997,-0.09419107,48.51,1.389108271804852,13.180006433628284,1.5790361649867068e-12,0.21454693085303153,439523.8649224451,0.48661880697152904,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-430,SOLEX ENERGY LTD,Mono-c-Si,0,430.0,401.1,2.17,,,60.0,13.18,41.33,12.57,34.23,0.0017265800000000001,-0.09452171,47.31,1.3931342702839662,13.18000640679222,1.7208134526728948e-12,0.21382035335838434,439870.2386560749,0.915296294428118,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-435,SOLEX ENERGY LTD,Mono-c-Si,0,435.0,404.9,2.17,,,60.0,13.26,41.5,12.65,34.4,0.00230724,-0.09457850000000001,48.51,1.3954370725121876,13.260006302429634,1.609591595287431e-12,0.2114691772454706,444921.4157925549,0.5961136237640654,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-435,SOLEX ENERGY LTD,Mono-c-Si,0,435.0,405.8,2.17,,,60.0,13.26,41.5,12.65,34.4,0.00173706,-0.09491050000000001,47.31,1.4040751453532765,13.264275573092332,1.924097904377457e-12,0.2099936650165934,651.2614673726363,1.8215085697333504,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-440,SOLEX ENERGY LTD,Mono-c-Si,0,440.0,409.6,2.17,,,60.0,13.34,41.67,12.73,34.57,0.0023211599999999996,-0.09496593,48.51,1.4061611415536384,13.344135873799313,1.7923969522077208e-12,0.2077168299146299,669.9775314472033,1.4665376954180693,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-440,SOLEX ENERGY LTD,Mono-c-Si,0,440.0,410.6,2.17,,,60.0,13.34,41.67,12.73,34.57,0.00174754,-0.09529929,47.31,1.4058373506872472,13.340006157478816,1.7879754108933287e-12,0.20770399562507258,449985.51429499115,1.1347289022057938,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-445,SOLEX ENERGY LTD,Mono-c-Si,0,445.0,414.4,2.17,,,60.0,13.43,41.84,12.81,34.74,0.00233682,-0.09535336000000001,48.51,1.4127028823860315,13.434682269464487,1.834101851474751e-12,0.20460588109649908,586.8643428432939,1.6062239611517042,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-445,SOLEX ENERGY LTD,Mono-c-Si,0,445.0,415.4,2.17,,,60.0,13.43,41.84,12.81,34.74,0.0017593300000000001,-0.09568808000000001,47.31,1.4167477747204633,13.434546619823877,1.996187602959228e-12,0.20388731793346768,602.2510986141907,2.025767821944145,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-450,SOLEX ENERGY LTD,Mono-c-Si,0,450.0,419.2,2.17,,,60.0,13.52,41.99,12.9,34.89,0.0023524799999999997,-0.09569521,48.51,1.4180374226272388,13.524371369485403,1.857400078385548e-12,0.20173655248626485,623.9413548970779,1.6549438354688515,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-450,SOLEX ENERGY LTD,Mono-c-Si,0,450.0,420.2,2.17,,,60.0,13.52,41.99,12.9,34.89,0.00177112,-0.09603113,47.31,1.4220974960544999,13.524237350591289,2.021508196098776e-12,0.20101999136981907,641.3890816705218,2.0744089200346876,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-455,SOLEX ENERGY LTD,Mono-c-Si,0,455.0,424.0,2.17,,,60.0,13.6,42.16,12.98,35.06,0.0023664,-0.09608264,48.51,1.4241310820369466,13.60410384041774,1.8826160758158623e-12,0.19885342431548308,658.9940898738047,1.7177520325925522,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-455,SOLEX ENERGY LTD,Mono-c-Si,0,455.0,425.0,2.17,,,60.0,13.6,42.16,12.98,35.06,0.0017816000000000002,-0.09641991999999999,47.31,1.4282086649504382,13.60397159351047,2.048911662967926e-12,0.1981378223822609,678.4869800162629,2.1371529518480195,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-460,SOLEX ENERGY LTD,Mono-c-Si,0,460.0,428.8,2.17,,,60.0,13.69,42.31,13.07,35.21,0.0023820599999999996,-0.09642449,48.51,1.4294668356139124,13.693806255386532,1.9062262318598834e-12,0.19606106968023204,705.1751854991345,1.7659034752802245,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-460,SOLEX ENERGY LTD,Mono-c-Si,0,460.0,429.8,2.17,,,60.0,13.69,42.31,13.07,35.21,0.00179339,-0.09676297,47.31,1.4335596383215738,13.69367563419665,2.074571783631816e-12,0.19534741720006898,727.576796553238,2.1852330847132913,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB60HM10-465,SOLEX ENERGY LTD,Mono-c-Si,0,465.0,433.6,2.17,,,60.0,13.78,42.44,13.16,35.34,0.00239772,-0.09672076,48.51,1.434066607109865,13.783512875181607,1.927583754529721e-12,0.19350361392599214,759.0590824296293,1.8032709446152513,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB60HM10-465,SOLEX ENERGY LTD,Mono-c-Si,0,465.0,434.6,2.17,,,60.0,13.78,42.44,13.16,35.34,0.0018051800000000002,-0.09706028,47.31,1.438172455817807,13.783383718664961,2.0977843518803944e-12,0.1927923107463897,785.1356211098642,2.2225284531475857,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-475,SOLEX ENERGY LTD,Mono-c-Si,0,475.0,442.1,2.37,,,66.0,13.24,45.3,12.57,37.8,0.00230376,-0.10323869999999999,48.51,1.53604292123277,13.249237905938749,2.0381698941059144e-12,0.20781969641548298,297.85243567016755,2.644758850947462,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-475,SOLEX ENERGY LTD,Mono-c-Si,0,475.0,443.2,2.37,,,66.0,13.24,45.3,12.57,37.8,0.0017344400000000003,-0.10360109999999999,47.31,1.5404560382483792,13.249095555656382,2.2181272010394045e-12,0.20701698029546564,301.34550617398156,3.0658850890670797,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-480,SOLEX ENERGY LTD,Mono-c-Si,0,480.0,446.9,2.37,,,66.0,13.33,45.44,12.66,37.94,0.00231942,-0.10355775999999998,48.51,1.540975702078005,13.338895284119024,2.06007597212847e-12,0.2049879924133718,307.18411083518424,2.6764298923811536,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-480,SOLEX ENERGY LTD,Mono-c-Si,0,480.0,447.9,2.37,,,66.0,13.33,45.44,12.66,37.94,0.00174623,-0.10392127999999999,47.31,1.545402820183851,13.338754389632586,2.2419372734163285e-12,0.204188163649825,310.9101079455252,3.0974819777842364,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-485,SOLEX ENERGY LTD,Mono-c-Si,0,485.0,451.7,2.37,,,66.0,13.41,45.58,12.74,38.08,0.0023333399999999997,-0.10387682,48.51,1.5459363083804996,13.418590819837862,2.0815223449881e-12,0.20234565449120392,315.85521311079754,2.7122151466495787,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-485,SOLEX ENERGY LTD,Mono-c-Si,0,485.0,452.7,2.37,,,66.0,13.41,45.58,12.74,38.08,0.00175671,-0.10424146,47.31,1.5503776161868257,13.418451338536658,2.2652478186922056e-12,0.20154800574098286,319.8024489793519,3.1332084083473353,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-490,SOLEX ENERGY LTD,Mono-c-Si,0,490.0,456.4,2.37,,,66.0,13.49,45.73,12.82,38.23,0.00234726,-0.10421867,48.51,1.5512672027509444,13.498288626192478,2.104288080236876e-12,0.1996348750578164,324.9120624713168,2.7527751888748555,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-490,SOLEX ENERGY LTD,Mono-c-Si,0,490.0,457.5,2.37,,,66.0,13.49,45.73,12.82,38.23,0.0017671899999999999,-0.10458450999999999,47.31,1.5557238248672758,13.498150626983916,2.289992507369659e-12,0.19883915352879492,329.09617754891065,3.1737148285851178,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-495,SOLEX ENERGY LTD,Mono-c-Si,0,495.0,461.2,2.37,,,66.0,13.57,45.88,12.9,38.38,0.00236118,-0.10456052,48.51,1.5565988394628338,13.57799210784978,2.1271822862041193e-12,0.19695764832384516,334.419322537037,2.7931813107641523,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-495,SOLEX ENERGY LTD,Mono-c-Si,0,495.0,462.3,2.37,,,66.0,13.57,45.88,12.9,38.38,0.0017776700000000003,-0.10492756,47.31,1.5610707969855042,13.577855606467496,2.314877249433187e-12,0.19616382686722453,338.8590232505521,3.214070614751228,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-500,SOLEX ENERGY LTD,Mono-c-Si,0,500.0,466.0,2.37,,,66.0,13.65,46.03,12.98,38.53,0.0023751,-0.10490237000000001,48.51,1.5619312134338312,13.65770120839593,2.1502049093492007e-12,0.19431335508965517,344.4105356495667,2.8334341456352603,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-500,SOLEX ENERGY LTD,Mono-c-Si,0,500.0,467.1,2.37,,,66.0,13.65,46.03,12.98,38.53,0.0017881500000000003,-0.10527061,47.31,1.5664185176066479,13.657566197399786,2.3399016305049596e-12,0.19352140833916562,349.1274531523606,3.2542750073185984,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-505,SOLEX ENERGY LTD,Mono-c-Si,0,505.0,470.8,2.37,,,66.0,13.73,46.18,13.06,38.68,0.00238902,-0.10524422,48.51,1.5672643066484786,13.737415841589824,2.1733554385790068e-12,0.19170139293896407,354.923995785142,2.8735326148867424,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-505,SOLEX ENERGY LTD,Mono-c-Si,0,505.0,471.9,2.37,,,66.0,13.73,46.18,13.06,38.68,0.00179863,-0.10561365999999998,47.31,1.5717669721011318,13.737282321675595,2.3650652310263733e-12,0.19091129568237764,359.9418167726531,3.2943270729720595,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB66HM10-510,SOLEX ENERGY LTD,Mono-c-Si,0,510.0,475.6,2.37,,,66.0,13.81,46.33,13.14,38.83,0.0024029399999999997,-0.10558606999999999,48.51,1.5725981040105268,13.817135930581527,2.196633442111835e-12,0.1891211739222501,366.0017969409337,2.9134756349081927,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB66HM10-510,SOLEX ENERGY LTD,Mono-c-Si,0,510.0,476.7,2.37,,,66.0,13.81,46.33,13.14,38.83,0.00180911,-0.10595671,47.31,1.5771161463220875,13.817003902755257,2.3903676387840714e-12,0.18833290105751707,371.34687032974523,3.334226322530449,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-520,SOLEX ENERGY LTD,Mono-c-Si,0,520.0,484.1,2.58,,,72.0,13.27,49.19,12.6,41.28,0.0023089799999999995,-0.11210400999999999,48.51,1.6721699377500465,13.2786249720392,2.199970493648076e-12,0.20411477402967057,314.04195200485907,3.277584697340535,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-520,SOLEX ENERGY LTD,Mono-c-Si,0,520.0,486.6,2.58,,,72.0,13.27,49.19,12.6,41.28,0.0037155999999999995,-0.11535055,46.18,1.7151681180333886,13.277472025081241,4.6043540851860735e-12,0.1963125850883178,348.64283548623496,6.489141474173371,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-520,SOLEX ENERGY LTD,Mono-c-Si,0,520.0,485.2,2.58,,,72.0,13.27,49.19,12.6,41.28,0.00173837,-0.11249753,47.31,1.676981564914247,13.278492458480294,2.394010438842099e-12,0.20323807034362815,317.5722558658808,3.699174131109786,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-525,SOLEX ENERGY LTD,Mono-c-Si,0,525.0,488.8,2.58,,,72.0,13.35,49.32,12.68,41.41,0.0023229,-0.11240028,48.51,1.6767391487215138,13.358345100375674,2.21978784869237e-12,0.20157656443621724,322.47031407326784,3.3013919657157222,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-525,SOLEX ENERGY LTD,Mono-c-Si,0,525.0,491.4,2.58,,,72.0,13.35,49.32,12.68,41.41,0.0037380000000000004,-0.1156554,46.18,1.7198605777658085,13.357203407871548,4.645969848976952e-12,0.19379911964431018,359.16590504850825,6.513854819753583,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-525,SOLEX ENERGY LTD,Mono-c-Si,0,525.0,490.0,2.58,,,72.0,13.35,49.32,12.68,41.41,0.0017488500000000001,-0.11279484,47.31,1.6815637877960763,13.358213852828456,2.4155517175307868e-12,0.20070278232939232,326.20284342123773,3.72292435276792,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-530,SOLEX ENERGY LTD,Mono-c-Si,0,530.0,493.6,2.58,,,72.0,13.43,49.45,12.76,41.54,0.00233682,-0.11269655,48.51,1.6813096916008252,13.4380697990257,2.2397139476977364e-12,0.19906985280340714,331.2979813575731,3.3252614934206566,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-530,SOLEX ENERGY LTD,Mono-c-Si,0,530.0,496.2,2.58,,,72.0,13.43,49.45,12.76,41.54,0.0037604,-0.11596025,46.18,1.7245544117707743,13.436939367044411,4.687812857906418e-12,0.1913168324901744,370.26216529958054,6.53862612060711,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-530,SOLEX ENERGY LTD,Mono-c-Si,0,530.0,494.8,2.58,,,72.0,13.43,49.45,12.76,41.54,0.0017593300000000001,-0.11309215,47.31,1.6861473853570559,13.43793982597249,2.4372124997853314e-12,0.19819894805170307,335.24814735747844,3.7467428068770907,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-535,SOLEX ENERGY LTD,Mono-c-Si,0,535.0,498.4,2.58,,,72.0,13.51,49.58,12.84,41.67,0.0023507399999999996,-0.11299282,48.51,1.6858815397063895,13.51779901397937,2.2597484381304654e-12,0.19659405765478172,340.5540405320082,3.3491895751323604,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-535,SOLEX ENERGY LTD,Mono-c-Si,0,535.0,501.0,2.58,,,72.0,13.51,49.58,12.84,41.67,0.0037828000000000002,-0.1162651,46.18,1.7292496132553423,13.516679876575703,4.729883825058263e-12,0.18886514574260635,381.9783341223646,6.563453451092907,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-535,SOLEX ENERGY LTD,Mono-c-Si,0,535.0,499.6,2.58,,,72.0,13.51,49.58,12.84,41.67,0.0017698100000000001,-0.11338946,47.31,1.690732247578667,13.517670304488384,2.4589889415847992e-12,0.19572600138815074,344.73967578834566,3.7706132690329106,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-540,SOLEX ENERGY LTD,Mono-c-Si,0,540.0,503.2,2.58,,,72.0,13.59,49.71,12.92,41.8,0.0023646599999999998,-0.11328909000000001,48.51,1.690454667681663,13.597532692060557,2.279890987092407e-12,0.19414861216730706,350.270477139142,3.3731714610822507,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-540,SOLEX ENERGY LTD,Mono-c-Si,0,540.0,505.8,2.58,,,72.0,13.59,49.71,12.92,41.8,0.0038052,-0.11656995,46.18,1.7339461483435465,13.596424873862821,4.772181549307623e-12,0.1864434993629508,394.36839042572177,6.588331959362125,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-540,SOLEX ENERGY LTD,Mono-c-Si,0,540.0,504.4,2.58,,,72.0,13.59,49.71,12.92,41.8,0.00178029,-0.11368677,47.31,1.6953184321673491,13.59740525483271,2.4808841555176503e-12,0.19328336141431401,354.7103975865874,3.7945440361189258,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-545,SOLEX ENERGY LTD,Mono-c-Si,0,545.0,508.0,2.58,,,72.0,13.67,49.84,13.0,41.93,0.00237858,-0.11358536000000001,48.51,1.6950290505619814,13.677270781475865,2.300141264937745e-12,0.19173296262924602,360.48251646862576,3.3972040686172797,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-545,SOLEX ENERGY LTD,Mono-c-Si,0,545.0,510.6,2.58,,,72.0,13.67,49.84,13.0,41.93,0.0038276000000000004,-0.11687480000000001,46.18,1.7386439903522957,13.676174307259956,4.814705274423027e-12,0.18405134613722152,407.49218203064333,6.613257452064631,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-545,SOLEX ENERGY LTD,Mono-c-Si,0,545.0,509.2,2.58,,,72.0,13.67,49.84,13.0,41.93,0.0017907700000000003,-0.11398408,47.31,1.6999058858982545,13.677144618203922,2.5028966085214053e-12,0.1908704805712361,365.19788733191587,3.818526658895458,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-550,SOLEX ENERGY LTD,Mono-c-Si,0,550.0,512.7,2.58,,,72.0,13.75,49.97,13.08,42.06,0.0023925,-0.11388162999999998,48.51,1.6996046639916471,13.757013230538636,2.320498935454467e-12,0.18934656933018137,371.22911019552765,3.42128296634158,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-550,SOLEX ENERGY LTD,Mono-c-Si,0,550.0,515.4,2.58,,,72.0,13.75,49.97,13.08,42.06,0.0038500000000000006,-0.11717964999999998,46.18,1.7433431149106104,13.755928124002642,4.857454400971655e-12,0.1816881514761438,421.4169792377256,6.638226647047374,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-550,SOLEX ENERGY LTD,Mono-c-Si,0,550.0,514.0,2.58,,,72.0,13.75,49.97,13.08,42.06,0.0018012500000000001,-0.11428138999999998,47.31,1.7044945840371233,13.756888343073806,2.525025933416673e-12,0.1884868196222857,376.2434224323977,3.842557265001848,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-555,SOLEX ENERGY LTD,Mono-c-Si,0,555.0,517.5,2.58,,,72.0,13.83,50.1,13.16,42.19,0.00240642,-0.1141779,48.51,1.7041814841231746,13.836759988817667,2.3409636652712843e-12,0.186988905214674,382.5533788466168,3.445404543156906,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-555,SOLEX ENERGY LTD,Mono-c-Si,0,555.0,520.3,2.58,,,72.0,13.83,50.1,13.16,42.19,0.0038724000000000002,-0.11748449999999999,46.18,1.7480434957678783,13.835686272643759,4.900428127167561e-12,0.17935339424553096,436.218522130958,6.6632355755341965,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-555,SOLEX ENERGY LTD,Mono-c-Si,0,555.0,518.8,2.58,,,72.0,13.83,50.1,13.16,42.19,0.0018117300000000001,-0.11457869999999999,47.31,1.7090845032163657,13.836636379434612,2.547271800473822e-12,0.18613185193596288,387.8927570679247,3.8666326824566912,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMB72HM10-560,SOLEX ENERGY LTD,Mono-c-Si,0,560.0,522.3,2.58,,,72.0,13.91,50.23,13.23,42.33,0.00242034,-0.11447416999999999,48.51,1.7095113923851084,13.917141731493906,2.390116775700625e-12,0.18375652010276053,357.9038500641398,3.5764603249558835,-0.3051,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMF72HM10-560,SOLEX ENERGY LTD,Mono-c-Si,0,560.0,525.1,2.58,,,72.0,13.91,50.23,13.23,42.33,0.0038948,-0.11778934999999999,46.18,1.7535371836396105,13.916056624232853,5.003524648302607e-12,0.17612831259272965,404.50665174239975,6.7975978872509275,-0.3145,N,2025.7.3,6/23/2025,4.0,first_pass +SOLEX ENERGY LTD SMFB72HM10-560,SOLEX ENERGY LTD,Mono-c-Si,0,560.0,523.6,2.58,,,72.0,13.91,50.23,13.23,42.33,0.00182221,-0.11487600999999999,47.31,1.7144322873673943,13.917016832496936,2.600752521377555e-12,0.18290036101889395,362.5772778615276,3.997946944599058,-0.3112,N,2025.7.3,6/23/2025,4.0,first_pass +SOLVIS doo SV50-225 E BC2 Kromatix Bronze,SOLVIS doo,Mono-c-Si,0,225.0,204.3,1.64,,,50.0,8.63,33.61,8.2,27.55,0.0025027000000000005,-0.097469,46.6,1.2873574148977174,8.631240883828163,3.950912606726501e-11,0.2628987521139318,1828.387582970451,5.99909923100157,-0.397,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees SS 270,Sonali Energees,Multi-c-Si,0,270.0,233.2,1.907104,1.954,0.976,72.0,8.05,43.2,7.5,36.0,0.004508,-0.16588800000000004,48.5,2.030334073285411,8.054569438547006,4.546938874718308e-09,0.17290416568791067,304.60632821912867,17.718848273319185,-0.545,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees SS 280,Sonali Energees,Multi-c-Si,0,280.0,242.1,1.907104,1.954,0.976,72.0,8.15,43.92,7.66,36.58,0.004564,-0.16865280000000002,48.5,2.052741659663492,8.15184645085534,4.132736567088993e-09,0.18025176080964167,795.6102823215134,16.644166860763153,-0.545,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees SS 290,Sonali Energees,Multi-c-Si,0,290.0,251.1,1.907104,1.954,0.976,72.0,8.3,43.92,7.9,36.72,0.004648,-0.16865280000000002,48.5,2.0499461310561298,8.35648004507134,4.14268709472138e-09,0.15697966807547828,999999.9843466869,16.41006097037162,-0.545,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees SS 300,Sonali Energees,Multi-c-Si,0,300.0,274.4,1.916874,1.954,0.981,72.0,8.45,44.64,7.98,37.58,0.0054925,-0.1477584,43.7,1.8914434331730194,8.452165671678953,4.717759407311403e-10,0.17166018794723992,669.7824820830143,13.080910612156496,-0.439,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees SS 310,Sonali Energees,Multi-c-Si,0,310.0,283.7,1.916874,1.954,0.981,72.0,8.55,45.36,8.17,37.9,0.005557500000000001,-0.15014160000000001,43.7,1.913242861169844,8.550001573362664,4.3203609956745173e-10,0.18395451485156922,999999.9096561167,12.14564890223467,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees SS 315,Sonali Energees,Multi-c-Si,0,315.0,288.4,1.916874,1.954,0.981,72.0,8.59,45.72,8.27,38.1,0.005583500000000001,-0.1513332,43.7,1.9336826453091707,8.590105435479876,4.6275254268431573e-10,0.14994248878759325,12216.109013099436,12.729939458960867,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees SS 320,Sonali Energees,Multi-c-Si,0,320.0,293.1,1.916874,1.954,0.981,72.0,8.62,46.08,8.36,38.3,0.005603,-0.15252480000000002,43.7,1.9528017310716068,8.620000972285549,4.869859942390427e-10,0.11275764689382929,999999.5594002947,13.163608781771796,-0.439,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-270,Sonali Energees USA LLC,Multi-c-Si,0,270.0,244.9,1.62,,,60.0,9.2,38.0,8.55,31.6,0.0043884,-0.140182,46.0,1.5884237160201666,9.21150132101464,3.6533823778737563e-10,0.1896988383396835,151.741649623806,-1.124540054844892,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-275,Sonali Energees USA LLC,Multi-c-Si,0,275.0,249.5,1.62,,,60.0,9.25,38.15,8.65,31.8,0.0044122499999999995,-0.14073535,46.0,1.5913184091249883,9.258030074995691,3.516579097906381e-10,0.1804653184573774,207.88153687465112,-1.4916608909290423,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-280,Sonali Energees USA LLC,Multi-c-Si,0,280.0,254.2,1.62,,,60.0,9.35,38.3,8.75,32.0,0.00445995,-0.14128870000000002,46.0,1.5991017188629166,9.357395063850289,3.639219421063286e-10,0.16933890099551285,214.10482561960362,-1.3063572454786683,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-295,Sonali Energees USA LLC,Mono-c-Si,0,295.0,270.9,1.61,,,60.0,9.55,39.6,9.05,32.6,0.0048991500000000006,-0.12347280000000001,45.4,1.5711018558350105,9.55241960615854,1.0759453742064643e-10,0.2502872567884695,987.8647701121014,5.685747897931503,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-300,Sonali Energees USA LLC,Mono-c-Si,0,300.0,275.6,1.61,,,60.0,9.7,39.7,9.2,32.7,0.004976099999999999,-0.12378460000000001,45.4,1.57484994146365,9.701849390573583,1.0900520122109731e-10,0.24487793749701034,1284.3779567910437,5.660812534088088,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-305,Sonali Energees USA LLC,Mono-c-Si,0,305.0,280.3,1.61,,,60.0,9.8,39.8,9.3,32.8,0.0050274000000000004,-0.1240964,45.4,1.5788344998382555,9.801482396608446,1.1022595631111326e-10,0.24083255970365877,1592.124319929604,5.666328528462093,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-310M,Sonali Energees USA LLC,Mono-c-Si,0,310.0,288.9,1.69,,,60.0,9.87,39.8,9.37,33.1,0.004441499999999999,-0.126962,43.1,1.5373389066454204,9.872465529991564,5.610051954043126e-11,0.2132188793656811,853.5570052369385,-2.1757772192330656,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-310MB,Sonali Energees USA LLC,Mono-c-Si,0,310.0,288.9,1.69,,,60.0,9.87,39.8,9.37,33.1,0.004441499999999999,-0.126962,43.1,1.5373389066454204,9.872465529991564,5.610051954043126e-11,0.2132188793656811,853.5570052369385,-2.1757772192330656,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-310,Sonali Energees USA LLC,Mono-c-Si,0,310.0,285.0,1.61,,,60.0,9.9,39.9,9.43,32.9,0.0050787,-0.12440820000000001,45.4,1.5827400530193925,9.90000306941006,1.1150894809230532e-10,0.23665549392700028,763396.9632724393,5.670435472942462,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-315M,Sonali Energees USA LLC,Mono-c-Si,0,315.0,293.6,1.69,,,60.0,9.95,40.1,9.44,33.4,0.0044775,-0.127919,43.1,1.5506834451040374,9.952885726691092,5.8186464375858814e-11,0.20683372903567385,713.1637576433934,-1.9484886047146641,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-315MB,Sonali Energees USA LLC,Mono-c-Si,0,315.0,293.6,1.69,,,60.0,9.95,40.1,9.44,33.4,0.0044775,-0.127919,43.1,1.5506834451040374,9.952885726691092,5.8186464375858814e-11,0.20683372903567385,713.1637576433934,-1.9484886047146641,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-315,Sonali Energees USA LLC,Mono-c-Si,0,315.0,289.8,1.61,,,60.0,10.0,40.0,9.55,33.0,0.00513,-0.12472000000000001,45.4,1.5890278746532005,10.000002170149946,1.168602983335966e-10,0.21698083150913758,999999.8260907069,5.984453454861893,-0.4035,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-320M,Sonali Energees USA LLC,Mono-c-Si,0,320.0,298.4,1.69,,,60.0,10.01,40.4,9.52,33.6,0.0045045,-0.128876,43.1,1.5591211169262893,10.011325452415914,5.5712116137756204e-11,0.21348614539019092,1612.2772114758836,-2.3482321064150833,-0.379,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sonali Energees USA LLC SS120H-320MB,Sonali Energees USA LLC,Mono-c-Si,0,320.0,298.4,1.69,,,60.0,10.01,40.4,9.52,33.6,0.0045045,-0.128876,43.1,1.5591211169262893,10.011325452415914,5.5712116137756204e-11,0.21348614539019092,1612.2772114758836,-2.3482321064150833,-0.379,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sonali Energees USA LLC SS-320,Sonali Energees USA LLC,Multi-c-Si,0,320.0,288.7,1.92,,,72.0,9.15,46.5,8.5,37.65,0.006222000000000001,-0.171864,46.1,1.9894823845362,9.164857637563887,6.327470502083883e-10,0.35601776424895576,219.25175303553908,2.9508838912585555,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-325M,Sonali Energees USA LLC,Mono-c-Si,0,325.0,303.2,1.69,,,60.0,10.08,40.7,9.59,33.9,0.004536,-0.129833,43.1,1.571669588898737,10.0811462801454,5.702245516185466e-11,0.20752547419578887,1824.909099630506,-2.220921318734436,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-325MB,Sonali Energees USA LLC,Mono-c-Si,0,325.0,303.2,1.69,,,60.0,10.08,40.7,9.59,33.9,0.004536,-0.129833,43.1,1.571669588898737,10.0811462801454,5.702245516185466e-11,0.20752547419578887,1824.909099630506,-2.220921318734436,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-325,Sonali Energees USA LLC,Multi-c-Si,0,325.0,293.4,1.92,,,72.0,9.2,46.6,8.6,37.8,0.006256,-0.17223360000000001,46.1,1.9890494338182165,9.209728189537906,6.06329159957328e-10,0.3460502537409862,327.2616252993469,2.5313161279039607,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-330M,Sonali Energees USA LLC,Mono-c-Si,0,330.0,308.0,1.69,,,60.0,10.16,41.0,9.66,34.2,0.0045720000000000005,-0.13079000000000002,43.1,1.585007086534092,10.161592337492843,5.909215692952487e-11,0.20133113313948076,1284.6048792195722,-1.99916232679581,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-330MB,Sonali Energees USA LLC,Mono-c-Si,0,330.0,308.0,1.69,,,60.0,10.16,41.0,9.66,34.2,0.0045720000000000005,-0.13079000000000002,43.1,1.585007086534092,10.161592337492843,5.909215692952487e-11,0.20133113313948076,1284.6048792195722,-1.99916232679581,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-330,Sonali Energees USA LLC,Multi-c-Si,0,330.0,298.0,1.92,,,72.0,9.25,46.7,8.7,37.95,0.0062900000000000005,-0.1726032,46.1,1.9887707655459554,9.25486817310813,5.819590527896825e-10,0.3362507725608728,638.9092947805206,2.12715580339854,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-335M,Sonali Energees USA LLC,Mono-c-Si,0,335.0,312.8,1.69,,,60.0,10.35,41.2,9.75,34.4,0.004657499999999999,-0.13142800000000002,43.1,1.6011631571403637,10.3573423863416,6.821929201543221e-11,0.1934428995860582,272.6816497374327,-0.9708078237115645,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-335MB,Sonali Energees USA LLC,Mono-c-Si,0,335.0,312.8,1.69,,,60.0,10.35,41.2,9.75,34.4,0.004657499999999999,-0.13142800000000002,43.1,1.6011631571403637,10.3573423863416,6.821929201543221e-11,0.1934428995860582,272.6816497374327,-0.9708078237115645,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-335,Sonali Energees USA LLC,Multi-c-Si,0,335.0,302.7,1.92,,,72.0,9.3,46.8,8.8,38.1,0.0063240000000000015,-0.17297279999999998,46.1,1.9886384387123235,9.30027074360877,5.594344016626646e-10,0.32661686958352143,11219.321201621484,1.737613937465004,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-340M,Sonali Energees USA LLC,Mono-c-Si,0,340.0,317.5,1.69,,,60.0,10.44,41.4,9.82,34.6,0.004698,-0.132066,43.1,1.6110340015100897,10.44820023735667,7.1024777509817e-11,0.18859456636919816,240.10613693819965,-0.7120454095973279,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-340MB,Sonali Energees USA LLC,Mono-c-Si,0,340.0,317.5,1.69,,,60.0,10.44,41.4,9.82,34.6,0.004698,-0.132066,43.1,1.6110340015100897,10.44820023735667,7.1024777509817e-11,0.18859456636919816,240.10613693819965,-0.7120454095973279,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-340,Sonali Energees USA LLC,Multi-c-Si,0,340.0,309.6,1.92,,,72.0,9.35,46.9,8.9,38.25,0.005162883,-0.16023384999999998,45.3,1.9375598338800684,9.350002912654459,2.8734645914641267e-10,0.31140597406803927,999999.8916770768,4.454325040166477,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-345,Sonali Energees USA LLC,Multi-c-Si,0,345.0,314.3,1.92,,,72.0,9.4,47.0,8.95,38.55,0.0051904920000000005,-0.1605755,45.3,1.9471812848852545,9.400002660212326,3.092875470952816e-10,0.2828978450197144,999999.1709747127,5.0311718804607946,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-345W-m60H,Sonali Energees USA LLC,Mono-c-Si,0,345.0,322.3,1.84,,,60.0,10.53,41.25,10.03,34.39,0.005991569999999999,-0.11389125000000001,43.8,1.5584147655749834,10.531092145026673,3.358793842727691e-11,0.20527383880763123,1979.16363619847,7.806695296151971,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-345W-m60HB,Sonali Energees USA LLC,Mono-c-Si,0,345.0,321.9,1.84,,,60.0,10.53,41.25,10.03,34.39,0.00616005,-0.12742125,43.9,1.5787918936919714,10.5307040045344,4.7296614069288905e-11,0.20082958348517294,3003.8668933084123,-1.0417211689411352,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-345W-m60HBi,Sonali Energees USA LLC,Mono-c-Si,1,345.0,322.1,1.84,,,60.0,10.53,41.25,10.03,34.39,0.00462267,-0.1215225,43.8,1.5477539683900705,10.531301854060326,2.7980703164282417e-11,0.20760770336044077,1679.2275928616612,-0.3257612591984272,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-350M,Sonali Energees USA LLC,Mono-c-Si,0,350.0,326.6,1.82,,,60.0,11.01,41.1,10.42,33.6,0.007376700000000001,-0.11590199999999999,43.2,1.590854274756974,11.01479315584693,6.59424276356961e-11,0.2585610566794457,593.9213161062096,10.937177710121963,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-350,Sonali Energees USA LLC,Multi-c-Si,0,350.0,319.0,1.92,,,72.0,9.45,47.1,9.0,38.9,0.005218101,-0.16091715,45.3,1.957996868345451,9.450002351515886,3.3759073651326017e-10,0.24874167782473292,999999.9418387699,5.7307985854247265,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-350W-m60H,Sonali Energees USA LLC,Mono-c-Si,0,350.0,327.1,1.84,,,60.0,10.59,41.4,10.06,34.79,0.006025709999999999,-0.1143054,43.8,1.5725263060899102,10.592840284630766,3.878612270652644e-11,0.17311799510851908,645.4703882944182,9.034184962399278,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-350W-m60HB,Sonali Energees USA LLC,Mono-c-Si,0,350.0,326.7,1.84,,,60.0,10.59,41.4,10.06,34.79,0.00619515,-0.1278846,43.9,1.5934157272289622,10.592460346352876,5.4808294232334006e-11,0.16854699245635907,725.4721393986703,0.11122169646889436,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-350W-m60HBi,Sonali Energees USA LLC,Mono-c-Si,1,350.0,326.9,1.84,,,60.0,10.59,41.4,10.06,34.79,0.00464901,-0.12196439999999999,43.8,1.5618611089638457,10.593040929415057,3.239368264622656e-11,0.175460548462941,611.0392579757236,0.8281823936151946,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-350,Sonali Energees USA LLC,Mono-c-Si,0,350.0,320.7,1.92,,,72.0,9.6,47.35,9.1,38.5,0.006115200000000001,-0.1519935,45.3,1.9107484653613873,9.600716089296872,1.6582589853918184e-10,0.34881362117963605,4676.248073005152,6.072978501387348,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-355M,Sonali Energees USA LLC,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007423600000000001,-0.11646599999999999,43.2,1.5977507291283435,11.082683521420803,6.562851166133219e-11,0.2542198533494791,1049.6492726894544,10.828813452057444,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-355MB,Sonali Energees USA LLC,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007423600000000001,-0.11646599999999999,43.2,1.5977507291283435,11.082683521420803,6.562851166133219e-11,0.2542198533494791,1049.6492726894544,10.828813452057444,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-355W-m60H,Sonali Energees USA LLC,Mono-c-Si,0,355.0,331.8,1.84,,,60.0,10.63,41.6,10.1,35.14,0.00604847,-0.11485760000000002,43.8,1.58418694323585,10.632606300786312,4.16421772783151e-11,0.1526063134462177,622.4167090353914,9.630494114976107,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-355W-m60HB,Sonali Energees USA LLC,Mono-c-Si,0,355.0,331.4,1.84,,,60.0,10.63,41.6,10.1,35.14,0.006218550000000001,-0.12850240000000002,43.9,1.6053928637719028,10.632260392593455,5.894559672488682e-11,0.1479676332310073,695.8508066451592,0.6719426572250132,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-355W-m60HBi,Sonali Energees USA LLC,Mono-c-Si,1,355.0,331.7,1.84,,,60.0,10.63,41.6,10.1,35.14,0.00466657,-0.1225536,43.8,1.5734903881651112,10.632787401562478,3.482313243803032e-11,0.15495496786291527,590.9343551677294,1.3888968197357725,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-355,Sonali Energees USA LLC,Mono-c-Si,0,355.0,325.4,1.92,,,72.0,9.65,47.45,9.18,38.7,0.006147050000000001,-0.15231450000000002,45.3,1.9191450505888477,9.650003101996413,1.7651807317674944e-10,0.32137608841483883,999999.9810286122,6.561858993447947,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-360M,Sonali Energees USA LLC,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.007470500000000001,-0.11703,43.2,1.6053907768603541,11.151534290661347,6.603224163928678e-11,0.24991284004409642,1816.1674290836768,10.82256652774573,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-360MB,Sonali Energees USA LLC,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.007470500000000001,-0.11703,43.2,1.6053907768603541,11.151534290661347,6.603224163928678e-11,0.24991284004409642,1816.1674290836768,10.82256652774573,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-360W-m60H,Sonali Energees USA LLC,Mono-c-Si,0,360.0,336.6,1.84,,,60.0,11.24,41.8,10.23,35.19,0.00639556,-0.1154098,43.8,1.624810180241933,11.266136035228971,7.135961482391429e-11,0.15056060863872167,64.74973089779319,14.177283501976222,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-360W-m60HB,Sonali Energees USA LLC,Mono-c-Si,0,360.0,336.2,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0065754,-0.1291202,43.9,1.647799265926316,11.264976095563732,1.0223137341234119e-10,0.14555818422640596,65.50559505620262,4.937568070973225,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-360W-m60HBi,Sonali Energees USA LLC,Mono-c-Si,1,360.0,336.5,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0049343600000000005,-0.12314279999999998,43.8,1.6143710749462203,11.26667103590045,6.040727023587574e-11,0.15284083591743033,64.41185897355605,5.694412837985603,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-360,Sonali Energees USA LLC,Mono-c-Si,0,360.0,330.1,1.92,,,72.0,9.7,47.65,9.26,38.9,0.0061789,-0.1529565,45.3,1.931244196090332,9.70000290887003,1.867795568217296e-10,0.2998158626650912,999999.7424601875,7.0045997225735235,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-365M,Sonali Energees USA LLC,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007517400000000001,-0.117594,43.2,1.6129984442128569,11.2200043324952,6.643604597725459e-11,0.24558382388199174,636040.283978564,10.814580407027249,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-365MB,Sonali Energees USA LLC,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007517400000000001,-0.117594,43.2,1.6129984442128569,11.2200043324952,6.643604597725459e-11,0.24558382388199174,636040.283978564,10.814580407027249,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-365MD,Sonali Energees USA LLC,Mono-c-Si,0,365.0,341.9,1.72,,,60.0,11.22,41.7,10.68,34.2,0.00561,-0.117594,43.4,1.5693068794376166,11.220671752071075,3.231925500795932e-11,0.25437365140240203,4248.700079517787,4.751418978641654,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-365W-m60H,Sonali Energees USA LLC,Mono-c-Si,0,365.0,341.4,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0064297,-0.115962,43.8,1.6279961137227528,11.324537698439016,6.707982110566852e-11,0.15453245804335491,71.16465260224258,13.540874505351042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-365W-m60HB,Sonali Energees USA LLC,Mono-c-Si,0,365.0,341.0,1.84,,,60.0,11.3,42.0,10.33,35.33,0.006610500000000001,-0.129738,43.9,1.6508546900057997,11.323455053150314,9.593789047779915e-11,0.1496146493374621,72.08022675703677,4.3396540493048095,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-365W-m60HBi,Sonali Energees USA LLC,Mono-c-Si,1,365.0,341.3,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0049607,-0.12373199999999998,43.8,1.6174541226173103,11.32504521912303,5.6682304177878583e-11,0.15680912308680353,70.74975428077438,5.090868735469773,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-365,Sonali Energees USA LLC,Mono-c-Si,0,365.0,334.8,1.92,,,72.0,9.75,47.85,9.34,39.1,0.006210750000000001,-0.15359850000000003,45.3,1.9433553177795968,9.75000270596473,1.9753599245882634e-10,0.2774724592805131,999995.9245761815,7.444971190028757,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-370M,Sonali Energees USA LLC,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.0075643,-0.11815799999999999,43.2,1.6222895238194939,11.290004304750692,6.852765624846108e-11,0.24111358937890323,632408.5507160096,11.037070427156209,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-370MB,Sonali Energees USA LLC,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.0075643,-0.11815799999999999,43.2,1.6222895238194939,11.290004304750692,6.852765624846108e-11,0.24111358937890323,632408.5507160096,11.037070427156209,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-370MD,Sonali Energees USA LLC,Mono-c-Si,0,370.0,346.8,1.72,,,60.0,11.29,41.9,10.76,34.4,0.005645000000000001,-0.11815799999999999,43.4,1.577396014730927,11.290004475392545,3.285709772933889e-11,0.25006042407380935,630846.4679260715,4.83578445186239,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-370M,Sonali Energees USA LLC,Mono-c-Si,0,370.0,344.8,2.01,,,72.0,9.91,48.1,9.31,39.7,0.0044595,-0.15343900000000002,43.1,1.8602348483667543,9.92013975442366,5.748663554477538e-11,0.2928614202349505,286.2255449351219,-1.9786049477888474,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-370MB,Sonali Energees USA LLC,Mono-c-Si,0,370.0,344.8,2.01,,,72.0,9.91,48.1,9.31,39.7,0.0044595,-0.15343900000000002,43.1,1.8602348483667543,9.92013975442366,5.748663554477538e-11,0.2928614202349505,286.2255449351219,-1.9786049477888474,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-370W-m60H,Sonali Energees USA LLC,Mono-c-Si,0,370.0,346.2,1.84,,,60.0,11.36,42.2,10.45,35.4,0.006463839999999999,-0.11651420000000001,43.8,1.6278813277492246,11.382761958473912,5.999208639221643e-11,0.16649289807193457,83.09299637870247,12.445711814615798,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-370W-m60HB,Sonali Energees USA LLC,Mono-c-Si,0,370.0,345.8,1.84,,,60.0,11.36,42.2,10.45,35.4,0.0066456,-0.13035580000000002,43.9,1.6504353567811691,11.381779156463201,8.554753600302316e-11,0.16171298513118007,84.34943423732544,3.31054810904644,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-370W-m60HBi,Sonali Energees USA LLC,Mono-c-Si,1,370.0,346.0,1.84,,,60.0,11.36,42.2,10.45,35.4,0.00498704,-0.1243212,43.8,1.6172082503039238,11.383235182170656,5.0543836988284634e-11,0.16876347395881114,82.51078281019736,4.053954503994833,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-370,Sonali Energees USA LLC,Mono-c-Si,0,370.0,339.6,1.92,,,72.0,9.8,48.05,9.42,39.3,0.006242600000000001,-0.1542405,45.3,1.9561422396272827,9.800215983672071,2.1047009379706932e-10,0.252195591251084,11443.100478560373,7.953481670500571,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-375M,Sonali Energees USA LLC,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.0076112,-0.118722,43.2,1.6315786824944178,11.360004275986642,7.066030917822844e-11,0.23670962361312473,628909.3176936881,11.257176931977938,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-375MB,Sonali Energees USA LLC,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.0076112,-0.118722,43.2,1.6315786824944178,11.360004275986642,7.066030917822844e-11,0.23670962361312473,628909.3176936881,11.257176931977938,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-375MD,Sonali Energees USA LLC,Mono-c-Si,0,375.0,351.6,1.72,,,60.0,11.36,42.1,10.84,34.6,0.00568,-0.118722,43.4,1.5864434089864505,11.360004448423606,3.3911918613419304e-11,0.24563853126698498,627313.450217703,5.051578407592452,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-375M,Sonali Energees USA LLC,Mono-c-Si,0,375.0,349.6,2.01,,,72.0,9.95,48.3,9.37,40.0,0.0044775,-0.154077,43.1,1.8691048267347408,9.958102228479532,5.877815311890728e-11,0.27644487557685316,339.4901274275561,-1.8425044399862636,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-375MB,Sonali Energees USA LLC,Mono-c-Si,0,375.0,349.6,2.01,,,72.0,9.95,48.3,9.37,40.0,0.0044775,-0.154077,43.1,1.8691048267347408,9.958102228479532,5.877815311890728e-11,0.27644487557685316,339.4901274275561,-1.8425044399862636,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-375,Sonali Energees USA LLC,Mono-c-Si,0,375.0,348.2,1.92,,,72.0,9.85,48.25,9.5,39.5,0.007905117500000001,-0.14325425,44.8,1.898558856231294,9.850209607393328,9.038580966234218e-11,0.25227117438093266,11854.896301569443,8.835981560451906,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-380M,Sonali Energees USA LLC,Mono-c-Si,0,380.0,354.3,2.01,,,72.0,10.0,48.5,9.42,40.3,0.0045,-0.154715,43.1,1.879953380563916,10.007611710971865,6.165464712144694e-11,0.25969643423998,341.1801124186423,-1.5036819798295826,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-380MB,Sonali Energees USA LLC,Mono-c-Si,0,380.0,354.3,2.01,,,72.0,10.0,48.5,9.42,40.3,0.0045,-0.154715,43.1,1.879953380563916,10.007611710971865,6.165464712144694e-11,0.25969643423998,341.1801124186423,-1.5036819798295826,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-380-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,380.0,356.9,1.95,,,54.0,13.41,36.1,12.65,30.0,0.0045594,-0.09169400000000001,43.2,1.3133464854029424,13.42240491249254,1.5258144145842933e-11,0.15872591611548476,171.58647245865842,8.206080589179086,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-380,Sonali Energees USA LLC,Mono-c-Si,0,380.0,353.0,1.92,,,72.0,9.9,48.45,9.58,39.7,0.007945245000000002,-0.14384805,44.8,1.9101644687955268,9.900160015980582,9.547992585894394e-11,0.22736095001114454,14066.572683842796,9.275726702523857,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-385M,Sonali Energees USA LLC,Mono-c-Si,0,385.0,359.1,2.01,,,72.0,10.06,48.7,9.49,40.6,0.004527000000000001,-0.15535300000000002,43.1,1.8897036215942566,10.066446509828827,6.382570146717984e-11,0.24307393132471175,379.32522418488884,-1.2804718817376433,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-385MB,Sonali Energees USA LLC,Mono-c-Si,0,385.0,359.1,2.01,,,72.0,10.06,48.7,9.49,40.6,0.004527000000000001,-0.15535300000000002,43.1,1.8897036215942566,10.066446509828827,6.382570146717984e-11,0.24307393132471175,379.32522418488884,-1.2804718817376433,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-385-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,385.0,361.7,1.95,,,54.0,13.53,36.2,12.77,30.2,0.0046002000000000005,-0.09194800000000002,43.2,1.3191870418949339,13.541438623790054,1.6121742881656316e-11,0.14728287277002153,174.2112788040011,8.61115276652098,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-385,Sonali Energees USA LLC,Mono-c-Si,0,385.0,357.7,1.92,,,72.0,9.95,48.65,9.65,39.9,0.0079853725,-0.14444184999999998,44.8,1.9209348861738653,9.950146670807648,9.968865130068386e-11,0.20789896650128015,14103.606068114472,9.613703899917482,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS108H-390MT,Sonali Energees USA LLC,Mono-c-Si,0,390.0,367.1,1.95,,,54.0,13.61,36.9,12.73,30.6,0.005444,-0.10553399999999999,43.1,1.3618983097732411,13.610004571632986,2.32728326490601e-11,0.1622753991499507,483112.6766151672,-0.8661447831957991,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-390M,Sonali Energees USA LLC,Mono-c-Si,0,390.0,363.9,2.01,,,72.0,10.12,49.0,9.55,40.8,0.004554,-0.15631,43.1,1.8997307079316885,10.126363908728173,6.28500101049896e-11,0.24925787755785084,396.37428776181827,-1.4519000312144146,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-390MB,Sonali Energees USA LLC,Mono-c-Si,0,390.0,363.9,2.01,,,72.0,10.12,49.0,9.55,40.8,0.004554,-0.15631,43.1,1.8997307079316885,10.126363908728173,6.28500101049896e-11,0.24925787755785084,396.37428776181827,-1.4519000312144146,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-390-108M-B,Sonali Energees USA LLC,Mono-c-Si,0,390.0,364.4,1.94,,,54.0,13.55,36.7,12.73,30.6,0.0055555000000000005,-0.10055800000000002,43.5,1.361603539327135,13.564786540904116,2.6170624306297123e-11,0.14658687425202563,134.3283848871843,4.582796908503118,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-390-108M-W,Sonali Energees USA LLC,Mono-c-Si,0,390.0,364.4,1.94,,,54.0,13.55,36.7,12.73,30.6,0.0055555000000000005,-0.10055800000000002,43.5,1.361603539327135,13.564786540904116,2.6170624306297123e-11,0.14658687425202563,134.3283848871843,4.582796908503118,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-390-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,390.0,366.5,1.95,,,54.0,13.65,36.3,12.88,30.3,0.004641000000000001,-0.09220199999999999,43.2,1.3233501211423422,13.66168609826632,1.6434957795136353e-11,0.14490223892170634,169.253717113251,8.704343046888456,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-M-390,Sonali Energees USA LLC,Mono-c-Si,0,390.0,362.5,1.92,,,72.0,10.0,48.8,9.73,40.1,0.008025500000000001,-0.1448872,44.8,1.9321555763900204,10.000235514517401,1.0736129438341114e-10,0.17297286543010829,7344.41154150259,10.230669883019006,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-SHDB108-390/M,Sonali Energees USA LLC,Mono-c-Si,1,390.0,362.1,1.94,,,54.0,13.54,36.7,12.79,30.5,0.0075823999999999996,-0.09798900000000002,46.1,1.3811033513120292,13.549310615901863,3.855335682339475e-11,0.15166678429914646,220.56202406792025,10.537983816822907,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108-395MB,Sonali Energees USA LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,37.0,12.81,30.8,0.007397999999999999,-0.10064000000000001,43.6,1.401112053396488,13.718401636004915,4.5467711736231086e-11,0.14579716737264542,108.54584935188754,9.914154993638125,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-395MB,Sonali Energees USA LLC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,37.0,12.81,30.8,0.007397999999999999,-0.10064000000000001,43.6,1.401112053396488,13.718401636004915,4.5467711736231086e-11,0.14579716737264542,108.54584935188754,9.914154993638125,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-395MT,Sonali Energees USA LLC,Mono-c-Si,0,395.0,371.9,1.95,,,54.0,13.7,37.0,12.81,30.8,0.00548,-0.10581999999999998,43.1,1.3593925511378533,13.720473002075579,2.0189883621233388e-11,0.15301758317370895,102.3953834512648,-1.9662302182213454,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-395M,Sonali Energees USA LLC,Mono-c-Si,0,395.0,368.7,2.01,,,72.0,10.19,49.2,9.62,41.1,0.004585499999999999,-0.15694800000000003,43.1,1.910445304445193,10.195890859576217,6.587633517488854e-11,0.2325460156608625,402.25775763219394,-1.1331802789572374,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-395MB,Sonali Energees USA LLC,Mono-c-Si,0,395.0,368.7,2.01,,,72.0,10.19,49.2,9.62,41.1,0.004585499999999999,-0.15694800000000003,43.1,1.910445304445193,10.195890859576217,6.587633517488854e-11,0.2325460156608625,402.25775763219394,-1.1331802789572374,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-395-108M-B,Sonali Energees USA LLC,Mono-c-Si,0,395.0,369.2,1.94,,,54.0,13.62,36.9,12.79,30.9,0.0055842,-0.101106,43.5,1.3655196704183559,13.634530584504319,2.4519241976571904e-11,0.13580875715278443,127.29806435833122,3.9936891881586893,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-395-108M-W,Sonali Energees USA LLC,Mono-c-Si,0,395.0,369.2,1.94,,,54.0,13.62,36.9,12.79,30.9,0.0055842,-0.101106,43.5,1.3655196704183559,13.634530584504319,2.4519241976571904e-11,0.13580875715278443,127.29806435833122,3.9936891881586893,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-395-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,395.0,371.3,1.95,,,54.0,13.76,36.5,12.98,30.4,0.0046784,-0.09271,43.2,1.3293739764519494,13.772399072656144,1.613760906602382e-11,0.1504310414634215,166.94250436409592,8.473228378249413,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB108-395/M,Sonali Energees USA LLC,Mono-c-Si,1,395.0,366.8,1.94,,,54.0,13.62,36.9,12.87,30.7,0.0076272,-0.098523,46.1,1.3891798503683634,13.628937187946065,3.920298518649281e-11,0.14859355955018455,226.4520158605057,10.6338783710813,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108-400MB,Sonali Energees USA LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.0,12.9,31.0,0.007446599999999999,-0.10064000000000001,43.6,1.405525586039239,13.806185608837279,4.971883658960144e-11,0.12698888506058306,108.19344250773712,10.654167514200976,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-400MB,Sonali Energees USA LLC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.0,12.9,31.0,0.007446599999999999,-0.10064000000000001,43.6,1.405525586039239,13.806185608837279,4.971883658960144e-11,0.12698888506058306,108.19344250773712,10.654167514200976,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-400MT,Sonali Energees USA LLC,Mono-c-Si,0,400.0,376.7,1.95,,,54.0,13.79,37.0,12.9,31.0,0.005516,-0.10581999999999998,43.1,1.3636494239152133,13.808120541990606,2.2123060545920747e-11,0.13421894471390966,102.14259903681547,-1.2887009788147514,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-400M,Sonali Energees USA LLC,Mono-c-Si,0,400.0,373.5,2.01,,,72.0,10.26,49.5,9.69,41.3,0.004617,-0.157905,43.1,1.9204186605223494,10.265780911962045,6.489368547582435e-11,0.23848631585440283,423.26706795778335,-1.3092004053721353,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-400MB,Sonali Energees USA LLC,Mono-c-Si,0,400.0,373.5,2.01,,,72.0,10.26,49.5,9.69,41.3,0.004617,-0.157905,43.1,1.9204186605223494,10.265780911962045,6.489368547582435e-11,0.23848631585440283,423.26706795778335,-1.3092004053721353,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-400-108M-B,Sonali Energees USA LLC,Mono-c-Si,0,400.0,374.0,1.94,,,54.0,13.7,37.1,12.86,31.1,0.005617,-0.10165400000000001,43.5,1.4134784547353774,13.713034196504074,5.359303465681408e-11,0.1259760051967862,132.411088426298,10.72002128733314,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-400-108M-W,Sonali Energees USA LLC,Mono-c-Si,0,400.0,374.0,1.94,,,54.0,13.7,37.1,12.86,31.1,0.005617,-0.10165400000000001,43.5,1.4134784547353774,13.713034196504074,5.359303465681408e-11,0.1259760051967862,132.411088426298,10.72002128733314,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-400-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,400.0,376.1,1.95,,,54.0,13.89,36.6,13.1,30.5,0.0047226,-0.09296400000000002,43.2,1.3103166114016094,13.903641325386968,1.0113060730528812e-11,0.15192063657500807,154.69007507938434,4.354567126864274,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB108-400/M,Sonali Energees USA LLC,Mono-c-Si,1,400.0,371.6,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007671999999999999,-0.099057,46.1,1.3972554244129742,13.708573768327355,3.9856506905113645e-11,0.14555899163443753,232.58830173746986,10.728581325313126,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108-405MB,Sonali Energees USA LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.2,12.98,31.2,0.0074898,-0.10118400000000002,43.6,1.4136049317724912,13.885653601947263,5.047677708958482e-11,0.12409551906465267,109.95583438500063,10.736597514315712,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-405MB,Sonali Energees USA LLC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.2,12.98,31.2,0.0074898,-0.10118400000000002,43.6,1.4136049317724912,13.885653601947263,5.047677708958482e-11,0.12409551906465267,109.95583438500063,10.736597514315712,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-405MT,Sonali Energees USA LLC,Mono-c-Si,0,405.0,381.5,1.95,,,54.0,13.87,37.2,12.98,31.2,0.005548,-0.106392,43.1,1.371485399529462,13.887561316340854,2.2465352022007424e-11,0.13132752368218847,103.72301968163913,-1.2133415747075074,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-405M,Sonali Energees USA LLC,Mono-c-Si,0,405.0,378.3,2.01,,,72.0,10.32,49.8,9.75,41.5,0.004644,-0.158862,43.1,1.9304509173704731,10.325684901568975,6.392122082427056e-11,0.24456885554910962,443.97438287608963,-1.477175164934782,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-405MB,Sonali Energees USA LLC,Mono-c-Si,0,405.0,378.3,2.01,,,72.0,10.32,49.8,9.75,41.5,0.004644,-0.158862,43.1,1.9304509173704731,10.325684901568975,6.392122082427056e-11,0.24456885554910962,443.97438287608963,-1.477175164934782,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-405-108M-B,Sonali Energees USA LLC,Mono-c-Si,0,405.0,378.8,1.94,,,54.0,13.77,37.4,12.94,31.3,0.0056457,-0.10247600000000001,43.5,1.422897736134163,13.782611771905572,5.198165210597448e-11,0.13104595069456157,143.08082746236533,10.396720652463058,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-405-108M-W,Sonali Energees USA LLC,Mono-c-Si,0,405.0,378.8,1.94,,,54.0,13.77,37.4,12.94,31.3,0.0056457,-0.10247600000000001,43.5,1.422897736134163,13.782611771905572,5.198165210597448e-11,0.13104595069456157,143.08082746236533,10.396720652463058,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB108-405/M,Sonali Energees USA LLC,Mono-c-Si,1,405.0,376.4,1.94,,,54.0,13.78,37.3,13.03,31.1,0.0077168,-0.099591,46.1,1.4053300916186309,13.788220164811934,4.0513883942915417e-11,0.14256235454485405,238.98660429173054,10.822114839467288,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108-410MB,Sonali Energees USA LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.3,13.04,31.5,0.007532999999999999,-0.101456,43.6,1.4233184991192205,13.964301567322108,5.652072432988775e-11,0.104494465020068,101.92573757276448,11.710011806016594,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-410MB,Sonali Energees USA LLC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.3,13.04,31.5,0.007532999999999999,-0.101456,43.6,1.4233184991192205,13.964301567322108,5.652072432988775e-11,0.104494465020068,101.92573757276448,11.710011806016594,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-410MT,Sonali Energees USA LLC,Mono-c-Si,0,410.0,386.3,1.95,,,54.0,13.95,37.3,13.04,31.5,0.00558,-0.106678,43.1,1.3808845754497403,13.966136673511057,2.5228126809577718e-11,0.11178450811125033,96.63663903982994,-0.32014571770850697,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-410M,Sonali Energees USA LLC,Mono-c-Si,0,410.0,383.1,2.01,,,72.0,10.38,50.1,9.82,41.8,0.004671,-0.15981900000000002,43.1,1.941981535244876,10.384785036312149,6.430387467302205e-11,0.23893413343172817,518.3108893937468,-1.4805442988715252,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-410MB,Sonali Energees USA LLC,Mono-c-Si,0,410.0,383.1,2.01,,,72.0,10.38,50.1,9.82,41.8,0.004671,-0.15981900000000002,43.1,1.941981535244876,10.384785036312149,6.430387467302205e-11,0.23893413343172817,518.3108893937468,-1.4805442988715252,-0.379,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-410-108M-B,Sonali Energees USA LLC,Mono-c-Si,0,410.0,383.6,1.94,,,54.0,13.85,37.6,13.02,31.5,0.0056785,-0.103024,43.5,1.4310116274533151,13.86216753677909,5.278849707914693e-11,0.12813037132865734,145.84756933862639,10.481115987981289,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-410-108M-W,Sonali Energees USA LLC,Mono-c-Si,0,410.0,383.6,1.94,,,54.0,13.85,37.6,13.02,31.5,0.0056785,-0.103024,43.5,1.4310116274533151,13.86216753677909,5.278849707914693e-11,0.12813037132865734,145.84756933862639,10.481115987981289,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-410-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,410.0,385.8,1.95,,,54.0,14.12,36.9,13.32,30.8,0.0048008,-0.093726,43.2,1.3303281979187567,14.120003903699796,1.2686683158866549e-11,0.14483228761481742,523876.3935281844,5.37229215155856,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB108-410/M,Sonali Energees USA LLC,Mono-c-Si,1,410.0,381.2,1.94,,,54.0,13.86,37.5,13.1,31.3,0.0077616000000000004,-0.100125,46.1,1.4139285285133854,13.868541943106624,4.1545145248748684e-11,0.13954682104728888,226.42611210108373,10.998238485631964,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-415MT,Sonali Energees USA LLC,Mono-c-Si,0,415.0,391.2,1.95,,,54.0,14.02,37.5,13.13,31.6,0.005608,-0.10724999999999998,43.1,1.3854072736159415,14.035647494177883,2.4027158642767278e-11,0.11805146185858889,105.7729424155366,-0.7617279535236223,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-415-54IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,415.0,390.6,1.95,,,54.0,14.21,37.1,13.43,30.9,0.0048314000000000005,-0.094234,43.2,1.3500160704743198,14.220932229567351,1.6296330909941502e-11,0.14813196976061668,192.54583788222408,8.267431682373257,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-415W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,415.0,387.7,2.21,,,72.0,11.23,49.6,10.08,41.15,0.006389870000000001,-0.13694560000000003,43.8,1.9271730242120406,11.275835023557631,6.944384325500057e-11,0.24537088518324618,60.11811118537737,13.981645867970887,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-415W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,415.0,387.3,2.21,,,72.0,11.23,49.6,10.08,41.15,0.0049299700000000005,-0.1461216,43.9,1.9147971237492492,11.276538175890673,5.87862246434601e-11,0.2480946212605528,59.86703508387783,5.515747616238673,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-415W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,415.0,387.5,2.21,,,72.0,11.23,49.6,10.08,41.15,0.0049299700000000005,-0.1461216,43.8,1.9147971237492492,11.276538175890673,5.87862246434601e-11,0.2480946212605528,59.86703508387783,5.515747616238673,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB108-415/M,Sonali Energees USA LLC,Mono-c-Si,1,415.0,386.0,1.94,,,54.0,13.94,37.7,13.18,31.5,0.0078064,-0.10065900000000003,46.1,1.3831989551967714,13.9496010036313,2.0039872941207657e-11,0.14314818734892837,207.84136968764992,4.574960867160664,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-420ND,Sonali Energees USA LLC,Mono-c-Si,0,420.0,395.5,2.8,,,54.0,14.07,38.1,13.33,31.5,0.005768700000000001,-0.09144,43.5,1.3160419798276801,14.08174165517922,3.717831992658109e-12,0.18447371226263387,221.05445077175094,1.5512677420077956,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-420-108M-B,Sonali Energees USA LLC,Mono-c-Si,0,420.0,393.2,1.94,,,54.0,13.92,37.8,13.1,32.0,0.0057072,-0.10357200000000001,43.5,1.4456618235209875,13.929190880856607,6.031342154260732e-11,0.09902825153925882,149.982822550165,11.628887435797424,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-420-108M-W,Sonali Energees USA LLC,Mono-c-Si,0,420.0,393.2,1.94,,,54.0,13.92,37.8,13.1,32.0,0.0057072,-0.10357200000000001,43.5,1.4456618235209875,13.929190880856607,6.031342154260732e-11,0.09902825153925882,149.982822550165,11.628887435797424,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-420W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,420.0,392.5,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00641263,-0.1374978,43.8,1.924275612696981,11.31293592026113,6.09726878700558e-11,0.2600136617475694,68.24947421628364,12.727371690319782,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-420W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,420.0,392.0,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00659295,-0.1538322,43.9,1.951007151081974,11.311542692840815,8.697378039427566e-11,0.25423863398445407,68.97168260170793,3.5691810931519705,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-420W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,420.0,392.3,2.21,,,72.0,11.27,49.8,10.19,41.2,0.00494753,-0.14671079999999997,43.8,1.9117347014768715,11.31359838481594,5.143806616521304e-11,0.262733302133244,67.91545931249719,4.327504679843871,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-425ND,Sonali Energees USA LLC,Mono-c-Si,0,425.0,400.3,2.8,,,54.0,14.15,38.2,13.41,31.7,0.005801500000000001,-0.09168000000000001,43.5,1.3216224907091914,14.16110747980652,3.917313393528794e-12,0.1739487139851639,221.59610915727413,1.9425769205246044,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-425M,Sonali Energees USA LLC,Mono-c-Si,0,425.0,396.8,2.18,,,72.0,11.03,49.3,10.48,40.6,0.0073901,-0.13902599999999998,43.2,1.9119598115230259,11.031464316312057,6.972557875689396e-11,0.27693687129037264,2086.0341442231634,11.409766097818249,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-425-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,425.0,399.2,2.17,,,60.0,13.37,40.2,12.66,33.6,0.0045458,-0.102108,43.2,1.4431647882792902,13.378914306541423,1.0558609573627848e-11,0.1637125720074879,245.54204937767167,5.029677154761112,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-425W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,425.0,397.2,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00642401,-0.13805,43.8,1.920119686782371,11.32762249190583,5.26150851471865e-11,0.27379873355090534,82.16329012473263,11.33962396657383,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-425W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,425.0,396.8,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00660465,-0.15445,43.9,1.946344078921541,11.326390454424786,7.477315224594048e-11,0.26821651782241673,83.21315458114935,2.2662306913522463,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-425W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,425.0,397.0,2.21,,,72.0,11.29,50.0,10.3,41.26,0.00495631,-0.1473,43.8,1.9074184082751062,11.3282278351693,4.422606743127526e-11,0.2765126468710977,81.66373491573208,3.0145851067784473,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-430ND,Sonali Energees USA LLC,Mono-c-Si,0,430.0,405.1,2.8,,,54.0,14.25,38.3,13.49,31.9,0.0058425000000000005,-0.09192,43.5,1.328034638670178,14.261978228324605,4.200012664535021e-12,0.16328957497258442,194.25881460843127,2.4768372448663043,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-430M,Sonali Energees USA LLC,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.0074303,-0.13959,43.2,1.919435708540418,11.09046953173212,6.993630184109553e-11,0.2727689192501563,6442.607267474282,11.383353055414567,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-430MB,Sonali Energees USA LLC,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.0074303,-0.13959,43.2,1.919435708540418,11.09046953173212,6.993630184109553e-11,0.2727689192501563,6442.607267474282,11.383353055414567,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-430-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,430.0,404.0,2.17,,,60.0,13.46,40.4,12.75,33.7,0.004576400000000001,-0.102616,43.2,1.4696380479150368,13.468114552003845,1.53423480626196e-11,0.16579462343495832,275.0115651264361,8.203866770259284,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-430W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,430.0,402.0,2.21,,,72.0,11.3,50.2,10.36,41.51,0.0064297,-0.1386022,43.8,1.9249664106109183,11.332475061769282,5.0969066282848636e-11,0.2657101017137451,92.4563034329522,11.027510616055379,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-430W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,430.0,401.5,2.21,,,72.0,11.3,50.2,10.36,41.51,0.006610500000000001,-0.1550678,43.9,1.9511598594549733,11.331348435421756,7.237893153737509e-11,0.2601647733633265,93.78018146089012,1.9743736468362443,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-430W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,430.0,401.8,2.21,,,72.0,11.3,50.2,10.36,41.51,0.0049607,-0.1478892,43.8,1.9121862296374148,11.333033207741956,4.280383197557569e-11,0.2684260255751194,91.82317754589283,2.71827473914128,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS108H-435ND,Sonali Energees USA LLC,Mono-c-Si,0,435.0,409.9,2.8,,,54.0,14.34,38.4,13.46,32.0,0.0058794,-0.09215999999999999,43.5,1.336997197521868,14.360939323608424,4.71104514343758e-12,0.161028237745155,110.27791419516095,3.4365930194774674,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-435MB,Sonali Energees USA LLC,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,41.0,12.96,33.6,0.007381800000000001,-0.11152000000000002,43.6,1.529753992196075,13.676110956682624,3.114263089377789e-11,0.21010601205766605,469.99993863841866,6.551713688813641,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-435MT,Sonali Energees USA LLC,Mono-c-Si,0,435.0,409.5,2.16,,,60.0,13.67,41.0,12.96,33.6,0.005468000000000001,-0.11726,43.1,1.4843840155110841,13.677912189080072,1.3707169899440546e-11,0.217754107143162,376.216828037193,-5.043530061490607,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-435M,Sonali Energees USA LLC,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.007477200000000001,-0.140154,43.2,1.9286393192589655,11.161051651425646,7.169511831905907e-11,0.26826678782777597,2846.8160066132386,11.55351734341314,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-435MB,Sonali Energees USA LLC,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.007477200000000001,-0.140154,43.2,1.9286393192589655,11.161051651425646,7.169511831905907e-11,0.26826678782777597,2846.8160066132386,11.55351734341314,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-435-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,435.0,408.8,2.17,,,60.0,13.55,40.5,12.83,33.9,0.004607000000000001,-0.10287,43.2,1.47606870611347,13.55821275341531,1.6256481947869962e-11,0.15467050293312543,255.1866860934464,8.657756452661879,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-435W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,435.0,406.8,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00643539,-0.13901635,43.8,1.924568686057769,11.336738709564765,4.731420417143629e-11,0.26420393433870276,111.75358010691457,10.326639687995666,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-435W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,435.0,406.3,2.21,,,72.0,11.31,50.35,10.44,41.66,0.006616350000000001,-0.15553115000000003,43.9,1.9505326261159281,11.335741569257468,6.706531849378671e-11,0.2587554721796313,113.68865618248695,1.3174222295105524,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-435W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,435.0,406.6,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00496509,-0.1483311,43.8,1.9117002752017433,11.337241145805205,3.9662350734410156e-11,0.2669145689428395,110.81779668211968,2.0553314445877207,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-440MB,Sonali Energees USA LLC,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.0,13.05,33.7,0.0074142,-0.11152000000000002,43.6,1.5302380974126233,13.733227689903009,3.1630274073642386e-11,0.20038228792807086,852.3894912001904,6.638704358612484,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-440MT,Sonali Energees USA LLC,Mono-c-Si,0,440.0,414.3,2.16,,,60.0,13.73,41.0,13.05,33.7,0.005492,-0.11726,43.1,1.4848459614153884,13.734864895316692,1.392336776063812e-11,0.20799411312467808,587.0134991642567,-4.965452337060757,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-440M,Sonali Energees USA LLC,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.0075241000000000014,-0.14071799999999998,43.2,1.9369573860521079,11.23083527858342,7.270263063616252e-11,0.26389598758029814,3547.9791857121936,11.62206061495409,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-440MB,Sonali Energees USA LLC,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.0075241000000000014,-0.14071799999999998,43.2,1.9369573860521079,11.23083527858342,7.270263063616252e-11,0.26389598758029814,3547.9791857121936,11.62206061495409,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-440MD,Sonali Energees USA LLC,Mono-c-Si,0,440.0,412.3,2.06,,,72.0,11.23,49.9,10.68,41.2,0.005615000000000001,-0.14071799999999998,43.4,1.8852046929852169,11.23187968176387,3.579431718107193e-11,0.2743794662231105,1639.2570147166125,5.618875433850381,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440-120M-B,Sonali Energees USA LLC,Mono-c-Si,0,440.0,411.3,2.15,,,60.0,13.54,41.2,12.74,34.5,0.0055514,-0.11288800000000002,43.5,1.566941346845056,13.55129469131013,5.0734903331238417e-11,0.14515198085687028,174.00722719641217,10.325153637140298,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440-120M-W,Sonali Energees USA LLC,Mono-c-Si,0,440.0,411.3,2.15,,,60.0,13.54,41.2,12.74,34.5,0.0055514,-0.11288800000000002,43.5,1.566941346845056,13.55129469131013,5.0734903331238417e-11,0.14515198085687028,174.00722719641217,10.325153637140298,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,440.0,413.6,2.17,,,60.0,13.66,40.6,12.91,34.1,0.0046444,-0.10312400000000001,43.2,1.483537433183889,13.669403607466512,1.754544774564429e-11,0.14335410436782833,208.24104821962558,9.270852637905,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440W-M60H-M10,Sonali Energees USA LLC,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.0,13.05,33.7,0.0075515,-0.12546000000000002,43.7,1.5453777111616855,13.732707358977587,4.1144527691424915e-11,0.19786257969884802,1003.4330283273594,-3.2657099796228066,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,440.0,411.6,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00645246,-0.1394305,43.8,1.9124794349887924,11.363041723554051,3.738174534735004e-11,0.26483785869404597,130.34013402256596,8.20169258294452,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,440.0,411.1,2.21,,,72.0,11.34,50.5,10.52,41.81,0.006633900000000001,-0.1559945,43.9,1.9518542605852915,11.361652353741434,6.373939404646147e-11,0.2566328218030774,134.40646053918988,0.8629499066944296,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-440W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,440.0,411.4,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00497826,-0.148773,43.8,1.9130868303524184,11.363019910950262,3.7697003654815584e-11,0.26471080823934795,130.40105109924505,1.5968095271374523,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-445MB,Sonali Energees USA LLC,Mono-c-Si,0,445.0,417.1,2.16,,,60.0,13.79,41.1,13.16,33.8,0.007446599999999999,-0.11179200000000002,43.6,1.5331244854823864,13.790002691854419,3.140486476311248e-11,0.19519241000659182,999999.8780740772,6.527530390213811,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-445MT,Sonali Energees USA LLC,Mono-c-Si,0,445.0,419.1,2.16,,,60.0,13.79,41.1,13.16,33.8,0.005516,-0.117546,43.1,1.4860652897982705,13.790082112848257,1.3436261361649417e-11,0.20606807647258446,34606.99312554475,-5.289723239165448,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-445M,Sonali Energees USA LLC,Mono-c-Si,0,445.0,415.9,2.18,,,72.0,11.29,50.1,10.75,41.4,0.0075643,-0.141282,43.2,1.944547697795038,11.291500623071004,7.301908241101061e-11,0.25984757693298205,999999.9472967179,11.607984773292271,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-445MB,Sonali Energees USA LLC,Mono-c-Si,0,445.0,415.9,2.18,,,72.0,11.29,50.1,10.75,41.4,0.0075643,-0.141282,43.2,1.944547697795038,11.291500623071004,7.301908241101061e-11,0.25984757693298205,999999.9472967179,11.607984773292271,-0.375,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-445MD,Sonali Energees USA LLC,Mono-c-Si,0,445.0,417.1,2.06,,,72.0,11.29,50.1,10.75,41.4,0.005645000000000001,-0.141282,43.4,1.892485592986177,11.290891194762988,3.58950737105374e-11,0.2703497589301323,3424.8938965777156,5.592670663819177,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-445-120M-B,Sonali Energees USA LLC,Mono-c-Si,0,445.0,416.1,2.15,,,60.0,13.6,41.4,12.8,34.8,0.005576,-0.11343600000000001,43.5,1.5774511208634077,13.610394831057391,5.3484426630994324e-11,0.13330744216293816,174.41180366803044,10.75664938478268,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-445-120M-W,Sonali Energees USA LLC,Mono-c-Si,0,445.0,416.1,2.15,,,60.0,13.6,41.4,12.8,34.8,0.005576,-0.11343600000000001,43.5,1.5774511208634077,13.610394831057391,5.3484426630994324e-11,0.13330744216293816,174.41180366803044,10.75664938478268,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-445-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,445.0,418.5,2.17,,,60.0,13.72,40.9,13.0,34.2,0.004664800000000001,-0.10388599999999999,43.2,1.4894084644040864,13.727804825708985,1.6103721059335462e-11,0.15737809812993134,276.6528813876334,8.461093127034236,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-445W-M60H-M10,Sonali Energees USA LLC,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.8,0.0075845,-0.12576600000000002,43.7,1.54887519213624,13.790002640990501,4.1246931495366104e-11,0.1914988580010622,999993.567934677,-3.289071706792257,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-445W-m72H,Sonali Energees USA LLC,Mono-c-Si,0,445.0,416.4,2.21,,,72.0,11.37,50.58,10.61,41.96,0.006469529999999999,-0.13965138000000002,43.8,1.9253852741335864,11.387332575414236,4.3222162224326944e-11,0.2532351485909144,166.11978286616585,9.432638289090042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-445W-m72HB,Sonali Energees USA LLC,Mono-c-Si,0,445.0,415.9,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00665145,-0.15624162000000003,43.9,1.9510767268211706,11.386540933617326,6.112345888567276e-11,0.24793320976451697,170.42572651439679,0.4803109068239914,-0.3593,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sonali Energees USA LLC SS-445W-m72HBi,Sonali Energees USA LLC,Mono-c-Si,1,445.0,416.2,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00499143,-0.14900868,43.8,1.9123979902602979,11.387740649298621,3.614853084898033e-11,0.2559254641843815,164.02288890230403,1.209671200758284,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-450MB,Sonali Energees USA LLC,Mono-c-Si,0,450.0,421.9,2.16,,,60.0,13.85,41.2,13.27,33.9,0.007479,-0.11206400000000001,43.6,1.5398499053856847,13.850002519631197,3.3229866633604754e-11,0.1819104539202851,999985.7845830459,6.978858187866988,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-450MT,Sonali Energees USA LLC,Mono-c-Si,0,450.0,423.9,2.16,,,60.0,13.85,41.2,13.27,33.9,0.005540000000000001,-0.117832,43.1,1.4923452289492147,13.850005262356458,1.417880400570299e-11,0.20341318200035158,535371.3949012496,-4.908321400703251,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-450M,Sonali Energees USA LLC,Mono-c-Si,0,450.0,420.7,2.18,,,72.0,11.36,50.3,10.82,41.6,0.0076112,-0.141846,43.2,1.9533989364656958,11.360004930482146,7.452420852214323e-11,0.25551519608597606,588746.2037499016,11.737619303589183,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-450MB,Sonali Energees USA LLC,Mono-c-Si,0,450.0,420.7,2.18,,,72.0,11.6,50.3,10.82,41.6,0.007772,-0.141846,43.2,1.9732041348905873,11.616888941294192,9.617928626223134e-11,0.24814421519705077,170.43536952644257,13.95932866543257,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-450MD,Sonali Energees USA LLC,Mono-c-Si,0,450.0,421.9,2.06,,,72.0,11.36,50.3,10.82,41.6,0.00568,-0.141846,43.4,1.9005757380090438,11.360681140901121,3.639810267833094e-11,0.26607399526943026,4437.556127462642,5.657753933572916,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-450-120M-B,Sonali Energees USA LLC,Mono-c-Si,0,450.0,420.9,2.15,,,60.0,13.66,41.6,12.86,35.0,0.0056006,-0.11398400000000002,43.5,1.5856026499361375,13.670066900401471,5.420747725207341e-11,0.13053853322554188,177.13062754084598,10.83645297084611,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-450-120M-W,Sonali Energees USA LLC,Mono-c-Si,0,450.0,420.9,2.15,,,60.0,13.66,41.6,12.86,35.0,0.0056006,-0.11398400000000002,43.5,1.5856026499361375,13.670066900401471,5.420747725207341e-11,0.13053853322554188,177.13062754084598,10.83645297084611,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-450-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,450.0,423.3,2.17,,,60.0,13.8,41.1,13.09,34.4,0.004692000000000001,-0.10439400000000001,43.2,1.4966273165373059,13.806820039923954,1.6197643990140224e-11,0.1544379092001904,312.4971681959102,8.45636360951781,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-450W-M60H-M10,Sonali Energees USA LLC,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.2,13.27,33.9,0.007617500000000001,-0.12607200000000002,43.7,1.551419129805903,13.927282806577212,4.079302308474387e-11,0.1930644441071485,103019.36501174951,-3.4490736509583555,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-455MB,Sonali Energees USA LLC,Mono-c-Si,0,455.0,426.7,2.16,,,60.0,13.93,41.3,13.36,34.1,0.007522200000000001,-0.112336,43.6,1.5465595465608057,13.930002353280006,3.518526499040645e-11,0.16892624032954812,999995.1003490807,7.425641680065245,-0.353,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS120H-455MT,Sonali Energees USA LLC,Mono-c-Si,0,455.0,428.8,2.16,,,60.0,13.93,41.3,13.36,34.1,0.0055720000000000006,-0.11811799999999999,43.1,1.498822755005881,13.930029821495355,1.5030414451911957e-11,0.19248971595635464,89914.62837458763,-4.500996356390241,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-455MB,Sonali Energees USA LLC,Mono-c-Si,0,455.0,425.5,2.18,,,72.0,11.41,50.4,10.88,41.8,0.007644700000000001,-0.14212799999999998,43.2,1.9353408198133144,11.41000481411554,5.590084028359657e-11,0.2472553756107915,586045.7224370706,9.127564567873018,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-455-120M-B,Sonali Energees USA LLC,Mono-c-Si,0,455.0,425.7,2.15,,,60.0,13.72,41.8,12.91,35.2,0.005625200000000001,-0.11453200000000001,43.5,1.5943760140040613,13.730276814146828,5.5448403704650506e-11,0.1276995531133126,170.4845360515125,11.002348522084858,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-455-120M-W,Sonali Energees USA LLC,Mono-c-Si,0,455.0,425.7,2.15,,,60.0,13.72,41.8,12.91,35.2,0.005625200000000001,-0.11453200000000001,43.5,1.5943760140040613,13.730276814146828,5.5448403704650506e-11,0.1276995531133126,170.4845360515125,11.002348522084858,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-455-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,455.0,428.1,2.17,,,60.0,13.92,41.4,13.16,34.6,0.0047328,-0.105156,43.2,1.5088270697887913,13.92998825880342,1.6659514759535185e-11,0.15843603120916502,220.80220475622068,8.642808511055486,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-460MT,Sonali Energees USA LLC,Mono-c-Si,0,460.0,433.6,2.16,,,60.0,14.01,41.5,13.45,34.2,0.0056040000000000005,-0.11869,43.1,1.5054311267052356,14.010005184195084,1.4938374210386468e-11,0.19767605274718605,534216.730598317,-4.593168454277231,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-460-120M-B,Sonali Energees USA LLC,Mono-c-Si,0,460.0,430.6,2.15,,,60.0,13.78,42.0,12.97,35.5,0.005649800000000001,-0.11508,43.5,1.6048760329727856,13.789356658736624,5.836397131312673e-11,0.11610083383142648,170.98726597041613,11.42308545647927,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-460-120M-W,Sonali Energees USA LLC,Mono-c-Si,0,460.0,430.6,2.15,,,60.0,13.78,42.0,12.97,35.5,0.005649800000000001,-0.11508,43.5,1.6048760329727856,13.789356658736624,5.836397131312673e-11,0.11610083383142648,170.98726597041613,11.42308545647927,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-460-60IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,460.0,432.9,2.17,,,60.0,14.04,41.6,13.21,34.8,0.0047736,-0.10566400000000001,43.2,1.5203057904013577,14.054206992337537,1.801978404063068e-11,0.1546582296274207,152.8403409299239,9.283480657297051,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-465ND,Sonali Energees USA LLC,Mono-c-Si,0,465.0,440.9,2.16,,,60.0,14.07,42.2,13.33,34.9,0.005768700000000001,-0.10128000000000001,43.5,1.4578650914542104,14.081715781975419,3.732656850102046e-12,0.20345040078889173,244.33257216201622,1.584751578694808,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-470ND,Sonali Energees USA LLC,Mono-c-Si,0,470.0,445.7,2.16,,,60.0,14.15,42.4,13.41,35.1,0.005801500000000001,-0.10175999999999999,43.5,1.4652520324538407,14.161326209509896,3.7905031114077684e-12,0.2003211312530385,250.26413387796586,1.6651616367460744,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-475ND,Sonali Energees USA LLC,Mono-c-Si,0,475.0,450.6,2.16,,,60.0,14.23,42.5,13.49,35.2,0.005834300000000001,-0.102,43.5,1.46884445690492,14.240985655061323,3.823415836463035e-12,0.19821309980714943,256.7504988624129,1.6891866793858585,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-480ND,Sonali Energees USA LLC,Mono-c-Si,0,480.0,455.4,2.16,,,60.0,14.31,42.6,13.57,35.4,0.0058671,-0.10224000000000001,43.5,1.4744029693406382,14.320415165306494,4.007056252521747e-12,0.18773994217584783,257.94680226745635,2.03628050643102,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-480MT,Sonali Energees USA LLC,Mono-c-Si,0,480.0,451.9,2.37,,,66.0,13.59,45.0,12.71,37.8,0.005436,-0.12869999999999998,43.1,1.6609002173864342,13.60719378139063,2.266532054661044e-11,0.15682016642089375,123.95098091071156,-0.975809117800945,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS120H-485ND,Sonali Energees USA LLC,Mono-c-Si,0,485.0,460.3,2.16,,,60.0,14.41,42.7,13.64,35.6,0.0059081,-0.10248,43.5,1.4813677624863901,14.422097714078276,4.309983469554475e-12,0.17708297574725457,210.92957493952974,2.6020048831814013,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-485MT,Sonali Energees USA LLC,Mono-c-Si,0,485.0,456.7,2.37,,,66.0,13.67,45.1,12.79,37.9,0.005468000000000001,-0.128986,43.1,1.6646156271831842,13.686845974197862,2.2817835352104222e-11,0.15485720239519746,125.66194980436288,-0.970570025878128,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-490MT,Sonali Energees USA LLC,Mono-c-Si,0,490.0,461.5,2.37,,,66.0,13.74,45.3,12.87,38.1,0.005496,-0.12955799999999998,43.1,1.6717740789318505,13.755810085155884,2.288036199868068e-11,0.1520298025891737,132.1238612091068,-0.9938353569862968,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-495MT,Sonali Energees USA LLC,Mono-c-Si,0,495.0,466.3,2.37,,,66.0,13.82,45.4,12.95,38.2,0.005528000000000001,-0.129844,43.1,1.6754954730872011,13.83547933816123,2.30348207276623e-11,0.15011905998937428,134.026752065609,-0.9878660365828106,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-500MT,Sonali Energees USA LLC,Mono-c-Si,0,500.0,471.2,2.37,,,66.0,13.9,45.6,13.03,38.4,0.005560000000000001,-0.130416,43.1,1.6832682103860963,13.915028183823084,2.3323548949670732e-11,0.14716247163618795,136.11480860664307,-0.9354986545219098,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-505MT,Sonali Energees USA LLC,Mono-c-Si,0,505.0,476.0,2.37,,,66.0,13.98,45.7,13.11,38.5,0.005592000000000001,-0.13070199999999998,43.1,1.6869930232286245,13.994708752340527,2.348004991552174e-11,0.14530392063605624,138.10476377630724,-0.9292855014601352,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-505-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,505.0,471.6,2.57,,,72.0,12.27,48.4,12.46,40.5,0.0050307,-0.132616,43.5,1.8778906819612968,12.270000887953415,7.859394731307207e-11,0.0009999942739727754,13818.213034405933,15.130769611191406,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-505-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,505.0,471.6,2.57,,,72.0,12.27,48.4,12.46,40.5,0.0050307,-0.132616,43.5,1.8778906819612968,12.270000887953415,7.859394731307207e-11,0.0009999942739727754,13818.213034405933,15.130769611191406,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-510-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,510.0,476.4,2.57,,,72.0,13.33,48.6,12.52,40.7,0.0054653,-0.13316400000000003,43.5,1.8501228107524041,13.342467024410535,5.109070725084125e-11,0.17338266957811577,185.3843333538123,10.534638086846627,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-510-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,510.0,476.4,2.57,,,72.0,13.33,48.6,12.52,40.7,0.0054653,-0.13316400000000003,43.5,1.8501228107524041,13.342467024410535,5.109070725084125e-11,0.17338266957811577,185.3843333538123,10.534638086846627,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-510-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,510.0,479.2,2.58,,,72.0,13.36,48.2,12.68,40.2,0.0045424,-0.12242800000000001,43.2,1.7516340166097977,13.366297312279507,1.485087607048434e-11,0.2000024549279859,424.3132154891582,7.974408806520335,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-515ND,Sonali Energees USA LLC,Mono-c-Si,0,515.0,488.4,2.37,,,66.0,14.21,46.3,13.45,38.3,0.005826100000000001,-0.11111999999999998,43.5,1.6003557674771287,14.222925488580158,3.823907663702469e-12,0.2202313449264799,242.11753372910906,1.7086753438789528,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-515-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,515.0,481.2,2.57,,,72.0,13.39,48.8,12.58,40.9,0.005489900000000001,-0.133712,43.5,1.7958120441294736,13.404028955488911,2.0717714486619574e-11,0.18140563102757953,173.1434255148437,2.725009435850728,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-515-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,515.0,481.2,2.57,,,72.0,13.39,48.8,12.58,40.9,0.005489900000000001,-0.133712,43.5,1.7958120441294736,13.404028955488911,2.0717714486619574e-11,0.18140563102757953,173.1434255148437,2.725009435850728,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-515-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,515.0,484.0,2.58,,,72.0,13.45,48.4,12.77,40.3,0.004573000000000001,-0.122936,43.2,1.7571754092504601,13.456075607010748,1.4560449194579217e-11,0.20550307938177176,454.9366738238042,7.740332967783866,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-520ND,Sonali Energees USA LLC,Mono-c-Si,0,520.0,493.2,2.37,,,66.0,14.27,46.4,13.54,38.4,0.0058507,-0.11135999999999999,43.5,1.6024061591203862,14.28002255061919,3.754373099903227e-12,0.21833548701213423,310.86393015226906,1.5084483223750886,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-520-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,520.0,486.0,2.57,,,72.0,13.45,49.0,12.64,41.1,0.0055145,-0.13426000000000002,43.5,1.8663455897725316,13.46179700192599,5.2305638867259155e-11,0.16739114396924643,190.84602383162024,10.662438584790392,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-520-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,520.0,486.0,2.57,,,72.0,13.45,49.0,12.64,41.1,0.0055145,-0.13426000000000002,43.5,1.8663455897725316,13.46179700192599,5.2305638867259155e-11,0.16739114396924643,190.84602383162024,10.662438584790392,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-520-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,520.0,488.8,2.58,,,72.0,13.52,48.5,12.84,40.5,0.0045968,-0.12319,43.2,1.7294428181797252,13.526626188340583,8.874274625248835e-12,0.20033350735247238,408.75823232453394,3.4458616189015197,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-525ND,Sonali Energees USA LLC,Mono-c-Si,0,525.0,498.1,2.37,,,66.0,14.35,46.6,13.65,38.5,0.0058835,-0.11184000000000001,43.5,1.6062567117637767,14.357115241745099,3.5840337205886997e-12,0.22352720737604892,450.8090590780684,1.0612555976347133,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-525-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,525.0,490.8,2.57,,,72.0,13.51,49.2,12.68,41.4,0.0055391,-0.134808,43.5,1.8783147578914288,13.522024318522416,5.5731832413721494e-11,0.15512841902122082,174.295529738621,11.19735456017256,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-525-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,525.0,490.8,2.57,,,72.0,13.51,49.2,12.68,41.4,0.0055391,-0.134808,43.5,1.8783147578914288,13.522024318522416,5.5731832413721494e-11,0.15512841902122082,174.295529738621,11.19735456017256,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-525-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,525.0,493.6,2.58,,,72.0,13.59,48.7,12.9,40.7,0.0046206,-0.12369800000000002,43.2,1.7714744247308514,13.59618398607253,1.550294198488624e-11,0.19130080767342816,420.40489217635167,8.201842740047924,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS132H-530ND,Sonali Energees USA LLC,Mono-c-Si,0,530.0,502.9,2.37,,,66.0,14.41,46.7,13.73,38.6,0.0059081,-0.11208,43.5,1.5936616573569198,14.41000591284218,2.7423598437341722e-12,0.22239562321944112,541994.9408934226,11.124447099036278,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-530MT,Sonali Energees USA LLC,Mono-c-Si,0,530.0,499.1,2.58,,,72.0,13.71,49.2,12.82,41.4,0.005484,-0.140712,43.1,1.8177168054163746,13.726885700899235,2.347840466886919e-11,0.16348162284110615,132.73556544102203,-0.7620307730197329,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-530-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,530.0,495.6,2.57,,,72.0,13.57,49.4,12.74,41.6,0.005563700000000001,-0.135356,43.5,1.8864227652601842,13.581691558925481,5.636307901052206e-11,0.15224458705703606,176.7051840238796,11.257651727246772,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-530-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,530.0,495.6,2.57,,,72.0,13.57,49.4,12.74,41.6,0.005563700000000001,-0.135356,43.5,1.8864227652601842,13.581691558925481,5.636307901052206e-11,0.15224458705703606,176.7051840238796,11.257651727246772,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-530-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,530.0,498.4,2.58,,,72.0,13.67,48.8,12.96,40.9,0.0046478000000000005,-0.12395199999999999,43.2,1.778635148602732,13.677092474721816,1.6438874067662317e-11,0.18019447490371374,347.3059128142679,8.672924719311515,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-530W-M72H-M10,Sonali Energees USA LLC,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.3,13.07,40.6,0.0075405,-0.150858,43.7,1.858183598973063,13.710003153012254,4.117608041323651e-11,0.22996538437530448,999999.871766718,-3.256973843069393,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-SHDB144-530/M,Sonali Energees USA LLC,Mono-c-Si,1,530.0,495.7,2.58,,,72.0,13.65,49.4,12.91,41.1,0.008599500000000001,-0.129922,45.5,1.8254975272395844,13.659070548349053,2.3866449065126317e-11,0.20426294470826037,307.38926847380367,7.783672063677799,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-535MD,Sonali Energees USA LLC,Mono-c-Si,0,535.0,504.0,2.57,,,72.0,13.78,49.4,12.9,41.5,0.0049608,-0.13683800000000002,43.2,1.8071668173209074,13.797193513399424,1.8058151585241188e-11,0.17221405352979038,138.0235446284227,0.33281632904610203,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-535MT,Sonali Energees USA LLC,Mono-c-Si,0,535.0,503.9,2.58,,,72.0,13.78,49.4,12.9,41.5,0.005512,-0.141284,43.1,1.822514816026605,13.796665255905195,2.2741037749837433e-11,0.1695403063963445,140.1877921182044,-1.0642107024438168,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-535-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,535.0,500.4,2.57,,,72.0,13.63,49.6,12.8,41.8,0.0055883,-0.13590400000000002,43.5,1.8945302364142642,13.641365100356614,5.6996604992526095e-11,0.1493882271443208,179.15913602325233,11.317394946899189,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-535-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,535.0,500.4,2.57,,,72.0,13.63,49.6,12.8,41.8,0.0055883,-0.13590400000000002,43.5,1.8945302364142642,13.641365100356614,5.6996604992526095e-11,0.1493882271443208,179.15913602325233,11.317394946899189,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-535-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,535.0,503.2,2.58,,,72.0,13.72,49.1,13.02,41.1,0.004664800000000001,-0.12471400000000002,43.2,1.7876488714916992,13.726382027308068,1.6039817359947393e-11,0.18524850411369964,398.2448485435538,8.419267590629861,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-535W-M72H-M10,Sonali Energees USA LLC,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.3,13.17,40.6,0.0075845,-0.150858,43.7,1.8596856077174728,13.790003069347254,4.2313416052705527e-11,0.22256478723287038,999999.8412292764,-3.089021057411157,-0.355,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-SHDB144-535/M,Sonali Energees USA LLC,Mono-c-Si,1,535.0,500.5,2.58,,,72.0,13.71,49.6,12.96,41.3,0.0086373,-0.130448,45.5,1.7959210782365007,13.720649581657963,1.3710647855705824e-11,0.2077253226352284,267.4202873910387,2.9889420551408024,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-540MD,Sonali Energees USA LLC,Mono-c-Si,0,540.0,508.8,2.57,,,72.0,13.85,49.5,12.97,41.7,0.004986,-0.13711500000000001,43.2,1.813091333563237,13.86610716871159,1.8783591630388587e-11,0.16147354042417808,138.84554015809388,0.6120094531351281,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-540MT,Sonali Energees USA LLC,Mono-c-Si,0,540.0,508.8,2.58,,,72.0,13.85,49.5,12.97,41.7,0.005540000000000001,-0.14156999999999997,43.1,1.8285216186657303,13.865594529876685,2.3658970186262416e-11,0.15879487076002038,141.0307965004113,-0.7876494396720093,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-540-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,540.0,505.2,2.57,,,72.0,13.7,49.8,12.86,42.0,0.005617,-0.13645200000000002,43.5,1.9033440127135945,13.711529013396602,5.8187692663182124e-11,0.1463361368437131,173.89216481694532,11.45946391909454,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-540-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,540.0,505.2,2.57,,,72.0,13.7,49.8,12.86,42.0,0.005617,-0.13645200000000002,43.5,1.9033440127135945,13.711529013396602,5.8187692663182124e-11,0.1463361368437131,173.89216481694532,11.45946391909454,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-540-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,540.0,508.0,2.58,,,72.0,13.8,49.4,13.09,41.3,0.004692000000000001,-0.125476,43.2,1.7978593677929469,13.806897730832024,1.5952213848975056e-11,0.18973251944151584,379.5898755514848,8.321621686406258,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-540W-M72H-M10,Sonali Energees USA LLC,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.4,13.27,40.7,0.007617500000000001,-0.151164,43.7,1.8660492731505065,13.850006032051267,4.409111811336126e-11,0.22695659972892146,521124.511300321,-2.7998412787542706,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB144-540/M,Sonali Energees USA LLC,Mono-c-Si,1,540.0,505.3,2.58,,,72.0,13.77,49.8,13.02,41.5,0.0086751,-0.130974,45.5,1.84202055510055,13.779240001659677,2.468861260046973e-11,0.19817211104870272,295.3278683524019,8.005943858995565,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-545MD,Sonali Energees USA LLC,Mono-c-Si,0,545.0,513.7,2.57,,,72.0,13.92,49.7,13.04,41.8,0.0050111999999999995,-0.137669,43.2,1.8185877664525838,13.936459824231562,1.837726960085145e-11,0.16737621586893997,141.54932026511332,0.3906677437283002,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-545MT,Sonali Energees USA LLC,Mono-c-Si,0,545.0,513.6,2.58,,,72.0,13.92,49.7,13.04,41.8,0.005568,-0.142142,43.1,1.8340400207104455,13.935940720497232,2.314408745731457e-11,0.16471144347818584,143.83184898116463,-1.0067463365185205,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-545-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,545.0,510.0,2.57,,,72.0,13.76,50.0,12.92,42.2,0.0056416,-0.137,43.5,1.911450632751649,13.77120516382531,5.882950505454602e-11,0.14353447157014093,176.26108660730966,11.517820017613568,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-545-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,545.0,510.0,2.57,,,72.0,13.76,50.0,12.92,42.2,0.0056416,-0.137,43.5,1.911450632751649,13.77120516382531,5.882950505454602e-11,0.14353447157014093,176.26108660730966,11.517820017613568,-0.368,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-545-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,545.0,512.9,2.58,,,72.0,13.87,49.6,13.16,41.4,0.0047158,-0.125984,43.2,1.8034649526769482,13.876783497498478,1.5636974814751224e-11,0.19540718177189412,399.54280718423615,8.099960334918729,-0.343,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sonali Energees USA LLC SS-SHDB144-545/M,Sonali Energees USA LLC,Mono-c-Si,1,545.0,510.1,2.58,,,72.0,13.83,50.0,13.07,41.7,0.0087129,-0.1315,45.5,1.8506210554220281,13.839664385758248,2.5218567517668896e-11,0.19513365240535965,279.2415890394617,8.156950951504486,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-550MD,Sonali Energees USA LLC,Mono-c-Si,0,550.0,518.5,2.57,,,72.0,13.99,49.8,13.11,42.0,0.0050364,-0.137946,43.2,1.824511061292898,14.00540395111646,1.9109600099699812e-11,0.15677801511280334,142.38713318551947,0.6679011759608745,-0.335,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-550MT,Sonali Energees USA LLC,Mono-c-Si,0,550.0,518.4,2.58,,,72.0,13.99,49.8,13.11,42.0,0.005596,-0.142428,43.1,1.8400454932892913,14.004900476948619,2.4070751679311814e-11,0.15410834765845804,144.69173037021588,-0.7321354881926299,-0.337,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-550-144M-B,Sonali Energees USA LLC,Mono-c-Si,0,550.0,514.8,2.57,,,72.0,13.82,50.2,12.98,42.4,0.005666200000000001,-0.137548,43.5,1.919556734441395,13.830887444046168,5.947352953027289e-11,0.1407591199376799,178.672886669936,11.575646929699259,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-550-144M-W,Sonali Energees USA LLC,Mono-c-Si,0,550.0,514.8,2.57,,,72.0,13.82,50.2,12.98,42.4,0.005666200000000001,-0.137548,43.5,1.919556734441395,13.830887444046168,5.947352953027289e-11,0.1407591199376799,178.672886669936,11.575646929699259,-0.368,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-550-72IIMJ,Sonali Energees USA LLC,Mono-c-Si,0,550.0,517.7,2.58,,,72.0,13.94,49.9,13.23,41.6,0.0047396,-0.126746,43.2,1.8130619959474517,13.946626152882528,1.541309462469945e-11,0.19998332139287878,420.7216220483757,7.9276238329371065,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS-SHDB144-550/M,Sonali Energees USA LLC,Mono-c-Si,1,550.0,514.9,2.58,,,72.0,13.89,50.2,13.13,41.9,0.0087507,-0.132026,45.5,1.85854337445892,13.899385936326567,2.5525693780204705e-11,0.19218419087066824,284.4083271386615,8.224652133782982,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-555MD,Sonali Energees USA LLC,Mono-c-Si,0,555.0,523.3,2.57,,,72.0,14.02,50.0,13.18,42.1,0.005047199999999999,-0.1385,43.2,1.8274322221389896,14.033534243968907,1.8000645872452027e-11,0.16345004417174258,169.31641192156906,0.1496490148557414,-0.335,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS144H-555MT,Sonali Energees USA LLC,Mono-c-Si,0,555.0,523.3,2.58,,,72.0,14.02,50.0,13.18,42.1,0.005608,-0.143,43.1,1.842935298986658,14.033061991031586,2.266780253735756e-11,0.16080489272716508,172.598848032139,-1.2445382027776486,-0.337,N,2025.7.3,6/23/2025,2.0,first_pass +Sonali Energees USA LLC SS-SHDB144-555/M,Sonali Energees USA LLC,Mono-c-Si,1,555.0,519.7,2.58,,,72.0,13.95,50.4,13.19,42.1,0.0087885,-0.132552,45.5,1.8664650283324231,13.959112917593322,2.5834126706629213e-11,0.18926203457876015,289.72119830783936,8.29173219126789,-0.33,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-560ND,Sonali Energees USA LLC,Mono-c-Si,0,560.0,531.0,2.58,,,72.0,14.18,50.4,13.39,41.8,0.005813800000000001,-0.12096,43.5,1.7460542294880452,14.195278952181992,4.063918399612277e-12,0.23099731921009936,214.38263285125151,2.250347316284869,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-565ND,Sonali Energees USA LLC,Mono-c-Si,0,565.0,535.9,2.58,,,72.0,14.23,50.6,13.48,41.9,0.005834300000000001,-0.12143999999999999,43.5,1.7491937575719947,14.241870325360097,3.845852301874858e-12,0.23671876764101277,283.7755476424443,1.7415919263022501,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-570ND,Sonali Energees USA LLC,Mono-c-Si,0,570.0,540.7,2.58,,,72.0,14.31,50.7,13.55,42.1,0.0058671,-0.12168,43.5,1.7552934428288427,14.322135088981055,4.03657442542647e-12,0.2260065554590744,266.5125754494616,2.104516866686443,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-575ND,Sonali Energees USA LLC,Mono-c-Si,0,575.0,545.6,2.58,,,72.0,14.39,50.9,13.62,42.2,0.0058999000000000005,-0.12215999999999999,43.5,1.761247299125889,14.402866408178042,3.993670727009673e-12,0.2311527884203851,258.5250356960395,1.968947288030271,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS144H-580ND,Sonali Energees USA LLC,Mono-c-Si,0,580.0,550.5,2.58,,,72.0,14.47,51.0,13.69,42.4,0.005932700000000001,-0.1224,43.5,1.7673472716502576,14.483064069365284,4.1898951303997645e-12,0.22057946816754978,244.31781324722718,2.329351125160378,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS156H-610ND,Sonali Energees USA LLC,Mono-c-Si,0,610.0,578.5,2.8,,,78.0,14.17,54.9,13.38,45.6,0.0058097,-0.13176000000000002,43.5,1.903331667637959,14.185071288175621,4.14614609464105e-12,0.24602096850754243,231.30850488034108,2.426124100244927,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS156H-615ND,Sonali Energees USA LLC,Mono-c-Si,0,615.0,583.4,2.8,,,78.0,14.25,55.1,13.46,45.7,0.0058425000000000005,-0.13224,43.5,1.9086716858406814,14.265017927947737,4.072451604534875e-12,0.2511360783448042,238.29446644023395,2.225215450340491,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS156H-620ND,Sonali Energees USA LLC,Mono-c-Si,0,620.0,588.2,2.8,,,78.0,14.3,55.3,13.54,45.8,0.005863000000000001,-0.13271999999999998,43.5,1.9122243981184648,14.312457561512382,3.8952388224896026e-12,0.25675375299479986,294.72691338928394,1.8097327776193726,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS156H-625ND,Sonali Energees USA LLC,Mono-c-Si,0,625.0,593.1,2.8,,,78.0,14.35,55.4,13.61,45.9,0.0058835,-0.13296,43.5,1.914602248689098,14.360513019661006,3.852952822076243e-12,0.2549013803347263,347.93379387237474,1.6813452868750653,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sonali Energees USA LLC SS156H-630ND,Sonali Energees USA LLC,Mono-c-Si,0,630.0,597.9,2.8,,,78.0,14.39,55.6,13.69,46.0,0.0058999000000000005,-0.13344,43.5,1.917617337794441,14.396946333969712,3.656635926472426e-12,0.2606020524429403,539.8622592375483,1.2054401579779768,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sova Solar Limited SS580144HCGT,Sova Solar Limited,Mono-c-Si,1,580.0,556.5,2.56,,,72.0,14.32,50.86,13.62,42.59,0.00481152,-0.11947014000000002,40.3,1.7266172896661804,14.327820754654207,2.2868936212718035e-12,0.20314517204836802,371.96395949778315,-0.36799908571727297,-0.2893,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-360W-m60H,Star Solar Inc,Mono-c-Si,0,360.0,336.6,1.84,,,60.0,11.24,41.8,10.23,35.19,0.00639556,-0.1154098,43.8,1.624810180241933,11.266136035228971,7.135961482391429e-11,0.15056060863872167,64.74973089779319,14.177283501976222,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-360W-m60HB,Star Solar Inc,Mono-c-Si,0,360.0,336.2,1.84,,,60.0,11.24,41.8,10.23,35.19,0.0065754,-0.1291202,43.9,1.647799265926316,11.264976095563732,1.0223137341234119e-10,0.14555818422640596,65.50559505620262,4.937568070973225,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-365W-m60H,Star Solar Inc,Mono-c-Si,0,365.0,341.4,1.84,,,60.0,11.3,42.0,10.33,35.33,0.0064297,-0.115962,43.8,1.6279961137227528,11.324537698439016,6.707982110566852e-11,0.15453245804335491,71.16465260224258,13.540874505351042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-370W-m60H,Star Solar Inc,Mono-c-Si,0,370.0,346.2,1.84,,,60.0,11.36,42.2,10.45,35.4,0.006463839999999999,-0.11651420000000001,43.8,1.6278813277492246,11.382761958473912,5.999208639221643e-11,0.16649289807193457,83.09299637870247,12.445711814615798,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-370W-m60HB,Star Solar Inc,Mono-c-Si,0,370.0,345.8,1.84,,,60.0,11.36,42.2,10.45,35.4,0.0066456,-0.13035580000000002,43.9,1.6504353567811691,11.381779156463201,8.554753600302316e-11,0.16171298513118007,84.34943423732544,3.31054810904644,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-435W-m72H,Star Solar Inc,Mono-c-Si,0,435.0,406.8,2.21,,,72.0,11.31,50.35,10.44,41.66,0.00643539,-0.13901635,43.8,1.924568686057769,11.336738709564765,4.731420417143629e-11,0.26420393433870276,111.75358010691457,10.326639687995666,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-435W-m72HB,Star Solar Inc,Mono-c-Si,0,435.0,406.3,2.21,,,72.0,11.31,50.35,10.44,41.66,0.006616350000000001,-0.15553115000000003,43.9,1.9505326261159281,11.335741569257468,6.706531849378671e-11,0.2587554721796313,113.68865618248695,1.3174222295105524,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-440W-M60H-M10,Star Solar Inc,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-440W-m72H,Star Solar Inc,Mono-c-Si,0,440.0,411.6,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00645246,-0.1394305,43.8,1.9124794349887924,11.363041723554051,3.738174534735004e-11,0.26483785869404597,130.34013402256596,8.20169258294452,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-440W-m72HB,Star Solar Inc,Mono-c-Si,0,440.0,411.1,2.21,,,72.0,11.34,50.5,10.52,41.81,0.006633900000000001,-0.1559945,43.9,1.9518542605852915,11.361652353741434,6.373939404646147e-11,0.2566328218030774,134.40646053918988,0.8629499066944296,-0.3593,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-440W-m72HBi,Star Solar Inc,Mono-c-Si,1,440.0,411.4,2.21,,,72.0,11.34,50.5,10.52,41.81,0.00497826,-0.148773,43.8,1.9130868303524184,11.363019910950262,3.7697003654815584e-11,0.26471080823934795,130.40105109924505,1.5968095271374523,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-445W-M60H-M10,Star Solar Inc,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Star Solar Inc STAR-445W-m72H,Star Solar Inc,Mono-c-Si,0,445.0,416.4,2.21,,,72.0,11.37,50.58,10.61,41.96,0.006469529999999999,-0.13965138000000002,43.8,1.9253852741335864,11.387332575414236,4.3222162224326944e-11,0.2532351485909144,166.11978286616585,9.432638289090042,-0.3551,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-445W-m72HB,Star Solar Inc,Mono-c-Si,0,445.0,415.9,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00665145,-0.15624162000000003,43.9,1.9510767268211706,11.386540933617326,6.112345888567276e-11,0.24793320976451697,170.42572651439679,0.4803109068239914,-0.3593,N,2025.7.3,6/23/2025,4.0,bootstrapping +Star Solar Inc STAR-445W-m72HBi,Star Solar Inc,Mono-c-Si,1,445.0,416.2,2.21,,,72.0,11.37,50.58,10.61,41.96,0.00499143,-0.14900868,43.8,1.9123979902602979,11.387740649298621,3.614853084898033e-11,0.2559254641843815,164.02288890230403,1.209671200758284,-0.3576,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-450W-M60H-M10,Star Solar Inc,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Star Solar Inc STAR-530W-M72H-M10,Star Solar Inc,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Star Solar Inc STAR-535W-M72H-M10,Star Solar Inc,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Star Solar Inc STAR-540W-M72H-M10,Star Solar Inc,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SG380WM,Sun Gold Power Inc,Mono-c-Si,0,380.0,358.5,1.9,,,54.0,13.2,36.3,12.45,30.5,0.006600000000000001,-0.094017,42.3,1.3448209247058784,13.209953986680421,2.4613066812678797e-11,0.12837865232900544,170.24316747149348,10.228109304042846,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG385WM,Sun Gold Power Inc,Mono-c-Si,0,385.0,363.3,1.9,,,54.0,13.35,36.4,12.6,30.6,0.006675,-0.094276,42.3,1.3484372584541953,13.35947641806061,2.486729516236999e-11,0.12588999941483836,177.34881391748593,10.216131044684593,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG390WM,Sun Gold Power Inc,Mono-c-Si,0,390.0,368.2,1.9,,,54.0,13.5,36.5,12.73,30.6,0.006750000000000001,-0.094535,42.3,1.3508729666577801,13.51074304275701,2.449727295023393e-11,0.13233078106103602,166.29046458010805,9.985330773594075,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG395WM,Sun Gold Power Inc,Mono-c-Si,0,395.0,373.0,1.9,,,54.0,13.52,36.6,12.75,31.0,0.0067599999999999995,-0.09479400000000002,42.3,1.3615143605590372,13.5288051645186,2.813276462653078e-11,0.1040662300095168,159.78979552048395,11.217188595277666,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-400-BBS,Sun Gold Power Inc,Mono-c-Si,1,400.0,372.2,1.95,,,54.0,13.39,37.2,12.74,31.4,0.007632300000000002,-0.09672000000000001,45.9,1.3988213809916061,13.392794992638784,3.759219364690049e-11,0.11343233083798697,543.4214530500334,13.371004738328592,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG405WM,Sun Gold Power Inc,Mono-c-Si,0,405.0,382.7,1.9,,,54.0,13.68,37.3,12.91,31.4,0.006840000000000001,-0.096607,42.3,1.3473234087990107,13.690845363195853,1.2759022306177114e-11,0.12820239758179616,161.7104722790411,4.192268092073913,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-405-BBS,Sun Gold Power Inc,Mono-c-Si,1,405.0,376.9,1.95,,,54.0,13.44,37.3,12.84,31.6,0.0076608,-0.09698,45.9,1.4023881415602926,13.440238653099167,3.776228365795236e-11,0.10341265267208843,5823.793737641172,13.360866269093359,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG410WM,Sun Gold Power Inc,Mono-c-Si,0,410.0,387.5,1.9,,,54.0,13.79,37.5,13.01,31.5,0.006895,-0.097125,42.3,1.3520168685010312,13.801621991819449,1.2209799158631518e-11,0.1340653617070877,159.07439725850645,3.7517200930727688,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-410-BBS,Sun Gold Power Inc,Mono-c-Si,1,410.0,381.7,1.95,,,54.0,13.59,37.7,12.88,31.8,0.0077463,-0.09802000000000002,45.9,1.3779203355531326,13.590048420636709,1.781793543187403e-11,0.12195132406755596,34227.553110877314,6.552336277328883,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG415WM,Sun Gold Power Inc,Mono-c-Si,0,415.0,392.3,1.9,,,54.0,13.92,37.6,13.13,31.6,0.00696,-0.097384,42.3,1.3931067221851232,13.930399504590076,2.601964203645775e-11,0.12543016826738057,167.8914546537824,10.24994016887551,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-415-BBS,Sun Gold Power Inc,Mono-c-Si,1,415.0,392.5,1.94,,,54.0,13.72,37.8,13.01,31.9,0.0063112,-0.09261,43.4,1.3504462217184632,13.727314234286037,9.46762716753763e-12,0.1253276439031525,235.08889840943974,7.549528339084867,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG420WM,Sun Gold Power Inc,Mono-c-Si,0,420.0,397.2,1.9,,,54.0,14.07,37.7,13.27,31.7,0.007035000000000001,-0.09764300000000002,42.3,1.3972413489018618,14.08050754799199,2.6514427968035668e-11,0.12303381157971,164.74687944166962,10.323295318392436,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-420-BBS,Sun Gold Power Inc,Mono-c-Si,1,420.0,398.4,1.94,,,54.0,13.4,38.5,12.76,32.9,0.005762,-0.08662500000000001,43.4,1.345859221782114,13.404153668118457,5.0101173360739674e-12,0.1008711231762245,325.4167197481677,11.468969249520214,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-420-SW5,Sun Gold Power Inc,Mono-c-Si,0,420.0,399.2,1.94,,,54.0,13.4,38.5,12.76,32.9,0.00603,-0.088935,43.1,1.3410778942457475,13.404264085872404,4.523649707879449e-12,0.10173630068908206,319.70895361895566,7.617653475486354,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-420-BBS,Sun Gold Power Inc,Mono-c-Si,1,420.0,397.3,1.94,,,54.0,13.8,38.0,13.09,32.1,0.006348,-0.0931,43.4,1.3580281996625938,13.807011667272619,9.61166189246993e-12,0.12256783411416615,241.23166778929567,7.63008606163274,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-425-BBS,Sun Gold Power Inc,Mono-c-Si,1,425.0,403.2,1.94,,,54.0,13.48,38.6,12.85,33.1,0.005796399999999999,-0.08685000000000001,43.4,1.3508550427222326,13.483330454384452,5.207706072074228e-12,0.09055619730069996,366.52582546802245,11.765222217432541,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-425-SW5,Sun Gold Power Inc,Mono-c-Si,0,425.0,404.0,1.94,,,54.0,13.48,38.6,12.85,33.1,0.006066,-0.08916600000000001,43.1,1.3271708847542678,13.483832433079446,3.1251106345292993e-12,0.09483187216135423,333.55667585704515,4.328032756307125,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG430WM,Sun Gold Power Inc,Mono-c-Si,0,430.0,406.9,1.9,,,60.0,13.56,39.7,12.79,33.6,0.0067800000000000004,-0.10282300000000001,42.3,1.476137917654342,13.568869166140498,2.7868402495153615e-11,0.11487063703291713,175.62483894844297,11.104346643841398,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-430-BBS,Sun Gold Power Inc,Mono-c-Si,1,430.0,408.1,1.94,,,54.0,13.57,38.8,12.95,33.2,0.0058351,-0.08729999999999999,43.4,1.3558368747940388,13.572909017997656,5.031580001401151e-12,0.09679733824798989,451.5406525733268,11.381992570335198,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-430-SW5,Sun Gold Power Inc,Mono-c-Si,0,430.0,408.9,1.94,,,54.0,13.57,38.8,12.95,33.2,0.006106500000000001,-0.089628,43.1,1.3510192910852932,13.573007903216716,4.542773368730125e-12,0.09765663635137578,440.57287231461515,7.533142339461228,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG435WM,Sun Gold Power Inc,Mono-c-Si,0,435.0,411.7,1.9,,,60.0,13.7,39.7,12.93,33.7,0.006849999999999999,-0.10282300000000001,42.3,1.477897482659703,13.7080122550092,2.90854783424313e-11,0.1049080034259001,179.38017145924067,11.395651684628504,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-435-BBS,Sun Gold Power Inc,Mono-c-Si,1,435.0,412.9,1.94,,,54.0,13.65,38.9,13.05,33.3,0.0058695,-0.087525,43.4,1.3584922303794913,13.651917381503985,4.982892544980988e-12,0.09542092387019115,679.3095937177932,11.229987357576185,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-435-BDG5,Sun Gold Power Inc,Mono-c-Si,1,435.0,413.3,2.0,,,48.0,15.9,34.5,14.73,29.5,0.0074730000000000005,-0.09487500000000001,43.2,1.2346275712245025,15.921064474001586,1.1171018433924579e-11,0.0703023694381524,53.06601412725349,-4.027367020618636,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sun Gold Power Inc SGN-435-SW5,Sun Gold Power Inc,Mono-c-Si,0,435.0,413.7,1.94,,,54.0,13.65,38.9,13.05,33.3,0.0061425,-0.08985900000000001,43.1,1.3536623571350335,13.652007423497547,4.498256248735694e-12,0.0962757111291419,654.6518293296084,7.385132311760694,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG440WM,Sun Gold Power Inc,Mono-c-Si,0,440.0,416.6,1.9,,,60.0,13.73,39.8,13.05,33.7,0.0068650000000000004,-0.103082,42.3,1.4746929795065207,13.734002494379999,2.5912891529277708e-11,0.11326106984508945,388.5263440503046,10.304474680631863,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-440-BBS,Sun Gold Power Inc,Mono-c-Si,1,440.0,417.8,1.94,,,54.0,13.73,39.0,13.15,33.5,0.0059039,-0.08775000000000001,43.4,1.3264280852317838,13.73156535825408,2.327785248044637e-12,0.0919294916541167,806.3278294948642,4.393148093315848,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-440-BDG5,Sun Gold Power Inc,Mono-c-Si,1,440.0,418.1,2.0,,,48.0,15.95,34.7,14.81,29.7,0.0074965000000000006,-0.09542500000000001,43.2,1.240962381312025,15.96922341289943,1.1029100596947846e-11,0.06850655950358929,56.84108387434099,-4.160806579480104,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGN-440-SW5,Sun Gold Power Inc,Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.73,39.0,13.15,33.5,0.0061785,-0.09009,43.1,1.3417145762807468,13.731305334316822,3.255621826661604e-12,0.08922016364770087,938.4514263166426,4.500310452743691,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG445WM,Sun Gold Power Inc,Mono-c-Si,0,445.0,421.4,1.9,,,60.0,13.81,40.3,13.15,33.8,0.0069050000000000005,-0.104377,42.3,1.4848778091841908,13.812955152131844,2.2464877577241364e-11,0.14237606845276424,665.35104171298,8.970217216291202,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-445-BBS,Sun Gold Power Inc,Mono-c-Si,1,445.0,422.7,1.94,,,54.0,13.81,39.2,13.25,33.6,0.0059383,-0.0882,43.4,1.3675953829832626,13.810017870354256,4.918121798950916e-12,0.09173316028876595,70890.07853347373,10.986001032859438,-0.299,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGN-445-BDG5,Sun Gold Power Inc,Mono-c-Si,1,445.0,423.0,2.0,,,48.0,16.0,34.9,14.89,29.9,0.00752,-0.095975,43.2,1.2472966532402356,16.01746578630881,1.0890536890069767e-11,0.06673054379608521,61.130296849716416,-4.292869107853173,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGN-445-SW5,Sun Gold Power Inc,Mono-c-Si,0,445.0,423.5,1.94,,,54.0,13.81,39.2,13.25,33.6,0.0062144999999999995,-0.09055200000000001,43.1,1.3627289026210065,13.810089442003575,4.438926131390693e-12,0.09258148648876004,14295.124463295771,7.147643037168908,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG450WM,Sun Gold Power Inc,Mono-c-Si,0,450.0,426.3,1.9,,,60.0,13.82,41.7,13.16,34.2,0.006910000000000001,-0.10800300000000002,42.3,1.5194655887162654,13.822066288702342,1.6631941952726226e-11,0.2147195309667707,1436.1129967991078,6.324315942622963,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-450-BBS,Sun Gold Power Inc,Mono-c-Si,1,450.0,427.5,1.94,,,54.0,13.89,39.3,13.35,33.8,0.005972699999999999,-0.08842499999999999,43.4,1.373839239206074,13.890001080590848,5.239470677466647e-12,0.07779578754938817,999999.0375297226,11.5122959499095,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-450-BDG5,Sun Gold Power Inc,Mono-c-Si,1,450.0,427.8,2.0,,,48.0,16.05,35.0,14.97,30.1,0.0075435,-0.09625000000000002,43.2,1.2518607119109237,16.064255035505674,1.1194890983305713e-11,0.05826103179094857,65.59714009053637,-4.109033246682619,-0.294,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGN-450-SW5,Sun Gold Power Inc,Mono-c-Si,0,450.0,428.3,1.94,,,54.0,13.89,39.3,13.34,33.8,0.0062505,-0.09078299999999999,43.1,1.3684682132808315,13.89004240699719,4.682572734616013e-12,0.08258720128069519,27050.640039386686,7.568932555721332,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG455WM,Sun Gold Power Inc,Mono-c-Si,0,455.0,431.2,1.9,,,60.0,14.06,41.7,13.26,34.3,0.007030000000000001,-0.10800300000000002,42.3,1.5285113250166382,14.073866321854059,1.9674949050548664e-11,0.20232552270106402,205.15151069502213,7.679878172595151,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-455-BBS,Sun Gold Power Inc,Mono-c-Si,1,455.0,432.4,1.94,,,54.0,13.97,39.4,13.45,33.9,0.0060071000000000005,-0.08865,43.4,1.3785042439277821,13.970001000737247,5.3990700785424284e-12,0.0716341254334455,999997.2660620132,11.73501544997622,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-455-SW5,Sun Gold Power Inc,Mono-c-Si,0,455.0,433.2,1.94,,,54.0,13.97,39.4,13.44,33.9,0.0062865,-0.09101400000000001,43.1,1.3716486218671742,14.001889792357641,4.691033380879443e-12,0.08104075355477575,999999.9823783779,7.514875442117718,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG460WM,Sun Gold Power Inc,Mono-c-Si,0,460.0,436.0,1.9,,,60.0,14.13,41.8,13.33,34.5,0.007065000000000001,-0.108262,42.3,1.534596032985791,14.14317609957642,2.0642045731780293e-11,0.19165006572441146,205.52481623959423,8.057177452952843,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-460-BBS,Sun Gold Power Inc,Mono-c-Si,1,460.0,437.2,1.94,,,54.0,14.05,39.6,13.55,34.0,0.0060415,-0.08910000000000001,43.4,1.3474062437344576,14.0500021186672,2.420108576585926e-12,0.09240594387676711,612793.7020148893,57.11726168130174,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-460-SW5,Sun Gold Power Inc,Mono-c-Si,0,460.0,438.1,1.94,,,54.0,14.05,39.6,13.54,34.0,0.0063225,-0.091476,43.1,1.3561589359226394,14.050002434380936,2.9256626937343224e-12,0.09089477278182624,524599.0633494868,3.369683468194707,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG480WM,Sun Gold Power Inc,Mono-c-Si,0,480.0,455.5,1.9,,,66.0,13.72,44.1,12.94,37.1,0.0068600000000000015,-0.114219,42.3,1.6348440768281995,13.730150582993133,2.602739857763386e-11,0.1459464594979955,197.2680227334745,10.383008633509325,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG485WM,Sun Gold Power Inc,Mono-c-Si,0,485.0,460.4,1.9,,,66.0,13.85,44.2,13.07,37.1,0.006925000000000001,-0.11447800000000002,42.3,1.6362385877621013,13.86020092798222,2.5313299126662996e-11,0.15234823644068524,206.84619075663153,10.046443933953933,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG490WM,Sun Gold Power Inc,Mono-c-Si,0,490.0,465.3,1.9,,,66.0,13.98,44.2,13.19,37.2,0.0069900000000000006,-0.11447800000000002,42.3,1.585546465267782,13.991674374801326,1.0751723066152507e-11,0.1512669364362027,181.1413298622155,2.566911475362451,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG495WM,Sun Gold Power Inc,Mono-c-Si,0,495.0,470.2,1.9,,,66.0,14.08,44.4,13.28,37.3,0.007040000000000001,-0.114996,42.3,1.6447767013498187,14.090645554723016,2.6199125801537687e-11,0.1477108363001752,195.36498010985628,10.209356083204579,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG500WM,Sun Gold Power Inc,Mono-c-Si,0,500.0,475.0,1.9,,,66.0,14.09,44.4,13.3,37.6,0.007045,-0.114996,42.3,1.6507700925794915,14.098607624014532,2.8923118400623357e-11,0.12182477092836423,199.41751965987274,11.090382003683127,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG505WM,Sun Gold Power Inc,Mono-c-Si,0,505.0,479.9,1.9,,,66.0,14.11,45.2,13.31,38.0,0.0070550000000000005,-0.117068,42.3,1.674927166636113,14.120434754274042,2.64758817157849e-11,0.1476584859976125,199.66557894153715,10.284035158480036,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG510WM,Sun Gold Power Inc,Mono-c-Si,0,510.0,484.8,1.9,,,66.0,14.18,45.4,13.38,38.1,0.007090000000000001,-0.11758600000000001,42.3,1.6805869042494166,14.190562665582615,2.5882681057903052e-11,0.15345312119670612,206.0053174511542,10.035204332772594,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG520WM,Sun Gold Power Inc,Mono-c-Si,0,520.0,494.6,1.9,,,72.0,13.57,48.3,12.8,40.6,0.006785000000000001,-0.125097,42.3,1.7897050722439514,13.580098126046826,2.5424944105026963e-11,0.16461395661174152,221.21052194026996,10.270937740302163,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG525WM,Sun Gold Power Inc,Mono-c-Si,0,525.0,499.5,1.9,,,72.0,13.68,48.4,12.91,40.7,0.006840000000000001,-0.125356,42.3,1.7933428724637306,13.689746927569022,2.5618598591780193e-11,0.16226729024197561,227.74525910973395,10.264580555695703,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG530WM,Sun Gold Power Inc,Mono-c-Si,0,530.0,504.4,1.9,,,72.0,13.75,48.6,12.97,40.9,0.006875000000000001,-0.125874,42.3,1.80186616689033,13.760011975733946,2.6166216860383085e-11,0.1592402138189198,218.69339388292914,10.410637623885394,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG535WM,Sun Gold Power Inc,Mono-c-Si,0,535.0,509.3,1.9,,,72.0,13.84,48.8,13.06,41.0,0.00692,-0.126392,42.3,1.8074255208983696,13.850069290480597,2.5633865264988913e-11,0.1649020300525015,226.6539159815433,10.165907652525632,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SG540WM,Sun Gold Power Inc,Mono-c-Si,0,540.0,514.2,1.9,,,72.0,13.92,48.9,13.09,41.1,0.00696,-0.126651,42.3,1.8145434400621094,13.932741856224807,2.7014293000585866e-11,0.16249525526740083,177.51997238498961,10.599697580322617,-0.339,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sun Gold Power Inc SG545WM,Sun Gold Power Inc,Mono-c-Si,0,545.0,519.1,1.9,,,72.0,14.0,49.5,13.1,41.6,0.007000000000000001,-0.128205,42.3,1.8411989370815893,14.016668478872624,2.8804486647054976e-11,0.16332466454740335,137.17780321652137,11.147254219599274,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-545-SBD,Sun Gold Power Inc,Mono-c-Si,1,545.0,514.7,2.58,,,72.0,13.94,49.5,13.38,40.8,0.005994199999999999,-0.121275,43.4,1.7524885006856314,13.940003194783396,7.540067208687992e-12,0.22917507323461922,999986.3104740464,5.424469635393828,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SG550WM,Sun Gold Power Inc,Mono-c-Si,0,550.0,524.1,1.9,,,72.0,14.01,49.9,13.11,42.0,0.007005000000000001,-0.129241,42.3,1.8574672215970018,14.026140664878714,2.940836337082752e-11,0.15893938968883564,137.95843420096253,11.328383638131186,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGP-550-SBD,Sun Gold Power Inc,Mono-c-Si,1,550.0,519.5,2.58,,,72.0,14.04,49.6,13.48,40.8,0.0060371999999999995,-0.12152000000000002,43.4,1.7548027542592421,14.040003277267392,7.445748486884795e-12,0.23341095058859312,999958.2269633487,5.254197530175013,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGP-555-SBD,Sun Gold Power Inc,Mono-c-Si,1,555.0,524.3,2.58,,,72.0,14.13,49.7,13.58,40.9,0.0060758999999999995,-0.12176500000000001,43.4,1.7593716799998822,14.130003588867451,7.61862936630527e-12,0.2274446972303749,895499.4089649264,5.397084595118906,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGP-560-SBD,Sun Gold Power Inc,Mono-c-Si,1,560.0,529.2,2.58,,,72.0,14.25,49.8,13.68,41.0,0.0061275,-0.12201,43.4,1.7624130515596916,14.2500032572822,7.622174028208004e-12,0.2285738761780051,999980.4441704596,5.328122583530237,-0.32,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGP-565-SBD,Sun Gold Power Inc,Mono-c-Si,1,565.0,534.0,2.58,,,72.0,14.37,49.8,13.78,41.0,0.006179099999999999,-0.12201,43.4,1.7616079527692305,14.370113155489252,7.586965047409594e-12,0.2417313088936215,30698.29287922492,5.216291023199204,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-580-BDG1,Sun Gold Power Inc,Mono-c-Si,1,580.0,550.7,2.58,,,72.0,13.8,52.0,13.17,44.0,0.0066240000000000005,-0.11336,43.2,1.8177634275046906,13.803149726776672,5.17694819042032e-12,0.1683882138787129,737.764778801581,15.018387476820768,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-585-BDG1,Sun Gold Power Inc,Mono-c-Si,1,585.0,555.6,2.58,,,72.0,13.85,52.2,13.23,44.2,0.006648000000000001,-0.11379600000000001,43.2,1.8245881198272904,13.852463521998361,5.187432048815055e-12,0.16587736019399885,932.5678665246049,14.998739184743348,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-590-BDG1,Sun Gold Power Inc,Mono-c-Si,1,590.0,560.5,2.58,,,72.0,13.9,52.4,13.29,44.4,0.006672000000000001,-0.114232,43.2,1.8314129212496657,13.901798173763762,5.1979354454374835e-12,0.16338941738961976,1263.0108296955545,14.979240298128214,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-595-BDG1,Sun Gold Power Inc,Mono-c-Si,1,595.0,565.3,2.58,,,72.0,13.95,52.5,13.35,44.6,0.006696,-0.11445000000000001,43.2,1.836331152857211,13.95119764265961,5.338068359614954e-12,0.1534234268381217,1787.0579474489339,15.19357296163031,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-600-BDG1,Sun Gold Power Inc,Mono-c-Si,1,600.0,570.2,2.58,,,72.0,14.0,52.7,13.41,44.8,0.006720000000000001,-0.114886,43.2,1.843154397752599,14.00060010737247,5.348226735652465e-12,0.15101513928300328,3523.056489730184,15.173180503576605,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Sun Gold Power Inc SGN-605-BDG1,Sun Gold Power Inc,Mono-c-Si,1,605.0,575.1,2.58,,,72.0,14.05,52.9,13.47,44.9,0.006744000000000001,-0.11532200000000001,43.2,1.8483209943055607,14.050002199425673,5.222990442345662e-12,0.15654185153919653,999999.7398126596,14.91030847004397,-0.301,N,2025.7.3,6/23/2025,2.0,first_pass +Sun Gold Power Inc SGN-610-BDG1,Sun Gold Power Inc,Mono-c-Si,1,610.0,579.9,2.58,,,72.0,14.1,53.1,13.53,45.1,0.006768,-0.115758,43.2,1.8564452715385193,14.100002129955097,5.334209181046718e-12,0.15105974882164258,999999.4846228177,15.076210764639487,-0.301,N,2025.7.3,6/23/2025,2.0,first_pass +SunEvo Solar Co Ltd SE4-72H-435MB,SunEvo Solar Co Ltd,Mono-c-Si,0,435.0,404.3,2.17,,,72.0,11.23,49.4,10.69,40.7,0.005615000000000001,-0.13436800000000002,46.2,1.8213825736598337,11.231866018831452,1.863415868267932e-11,0.28967539041326107,1743.3129509855075,3.8863792220727067,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE4-72H-440MB,SunEvo Solar Co Ltd,Mono-c-Si,0,440.0,409.1,2.17,,,72.0,11.3,49.6,10.76,40.9,0.0056500000000000005,-0.13491200000000003,46.2,1.8292840589439736,11.301631897095204,1.8902821576758032e-11,0.28529101414155994,1975.485249268253,3.9537297081495404,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE4-72H-445MB,SunEvo Solar Co Ltd,Mono-c-Si,0,445.0,413.9,2.17,,,72.0,11.37,49.8,10.83,41.1,0.005685,-0.13545600000000002,46.2,1.837185778875411,11.371403942198173,1.91733289304474e-11,0.28096363955783016,2275.4190242760724,4.020561597725543,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +SunEvo Solar Co Ltd SE4-72H-450MB,SunEvo Solar Co Ltd,Mono-c-Si,0,450.0,418.6,2.17,,,72.0,11.44,50.0,10.9,41.3,0.00572,-0.136,46.2,1.8450877281213045,11.44118205247124,1.9445674383110577e-11,0.27669216379316863,2677.8491068855983,4.086880320968866,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE4-72H-455MB,SunEvo Solar Co Ltd,Mono-c-Si,0,455.0,423.4,2.17,,,72.0,11.51,50.2,10.96,41.5,0.005755,-0.136544,46.2,1.8537861064088443,11.511783683050167,1.9929346401350253e-11,0.2724297250635558,1757.972795015433,4.245901956842951,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE4-72H-460MB,SunEvo Solar Co Ltd,Mono-c-Si,0,460.0,428.2,2.17,,,72.0,11.58,50.4,11.03,41.7,0.00579,-0.13708800000000002,46.2,1.8616873141104304,11.581562007007062,2.0207008762558357e-11,0.26826371971884133,1988.7836801830917,4.310714661550935,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE4-72H-465MB,SunEvo Solar Co Ltd,Mono-c-Si,0,465.0,433.0,2.17,,,72.0,11.65,50.6,11.1,41.9,0.005825,-0.137632,46.2,1.8695891575119614,11.651346227640957,2.0486609851854272e-11,0.26415047360861177,2285.9085043942905,4.375083926486335,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE4-72H-470MB,SunEvo Solar Co Ltd,Mono-c-Si,0,470.0,437.8,2.17,,,72.0,11.72,50.8,11.17,42.1,0.005860000000000001,-0.13817600000000002,46.2,1.8774902925650403,11.721136272006557,2.0767745382007187e-11,0.26008925232734026,2682.6730276794624,4.438853362275635,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-520MB,SunEvo Solar Co Ltd,Mono-c-Si,0,520.0,488.3,2.58,,,72.0,13.54,49.2,12.84,40.5,0.0073116,-0.12792,45.8,1.7372996936147656,13.549033069850978,6.7396927624527545e-12,0.2559409456627924,383.6392807707354,-1.4916476024150949,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-525MB,SunEvo Solar Co Ltd,Mono-c-Si,0,525.0,493.1,2.58,,,72.0,13.61,49.3,12.94,40.6,0.0073494,-0.12818000000000002,45.8,1.7438662163413259,13.610007248620775,7.180015565118307e-12,0.2526479301308021,474374.2977813291,-1.0512231186599341,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-535MB,SunEvo Solar Co Ltd,Mono-c-Si,0,535.0,502.8,2.58,,,72.0,13.75,49.5,13.13,40.8,0.007425,-0.1287,45.8,1.743513450578816,13.750884334758483,6.425314596117646e-12,0.24892973933409712,3870.461824429311,-2.0292922009472463,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-540MB,SunEvo Solar Co Ltd,Mono-c-Si,0,540.0,507.6,2.58,,,72.0,13.82,49.6,13.22,40.9,0.007462800000000001,-0.12896000000000002,45.8,1.7403983147536293,13.820006480688118,5.844984006999396e-12,0.2465556833732262,525780.315212462,3.6552184762481614,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-545MB,SunEvo Solar Co Ltd,Mono-c-Si,0,545.0,512.4,2.58,,,72.0,13.89,49.7,13.31,41.0,0.0075006,-0.12922000000000003,45.8,1.752600522933383,13.89000327040714,6.714887534321201e-12,0.2354473933449123,999998.1221807082,-1.758545847979298,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +SunEvo Solar Co Ltd SE5-72H-550MB,SunEvo Solar Co Ltd,Mono-c-Si,0,550.0,517.2,2.58,,,72.0,13.96,49.8,13.41,41.0,0.0075384,-0.12948,45.8,1.7559544462815133,13.96000667039889,6.72993857919434e-12,0.24956779565598644,522305.8671179885,-1.7810350280777945,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-555MB,SunEvo Solar Co Ltd,Mono-c-Si,0,555.0,522.0,2.58,,,72.0,14.03,49.9,13.5,41.1,0.0075762,-0.12974,45.8,1.7615716055941353,14.030003497316233,6.995292150148475e-12,0.22435647930835378,900047.9158391353,-1.508953999570958,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +SunEvo Solar Co Ltd SE5-72H-560MB,SunEvo Solar Co Ltd,Mono-c-Si,0,560.0,526.8,2.58,,,72.0,14.1,50.0,13.59,41.2,0.007613999999999999,-0.13,45.8,1.7657726803811873,14.100006320298125,7.106328663053569e-12,0.2444023770971338,545242.7799148203,-1.4088815231994762,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +SunEvo Solar Co Ltd SE5-72H-565MB,SunEvo Solar Co Ltd,Mono-c-Si,0,565.0,531.7,2.58,,,72.0,14.17,50.1,13.68,41.3,0.007651799999999999,-0.13026000000000001,45.8,1.771764958620162,14.170003258872333,7.427995837273129e-12,0.2075130949881013,902302.4771396016,-1.1029525476052142,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +SunEvo Solar Co Ltd SE5-72H-570MB,SunEvo Solar Co Ltd,Mono-c-Si,0,570.0,536.5,2.58,,,72.0,14.24,50.2,13.77,41.4,0.0076895999999999996,-0.13052,45.8,1.7757855711433936,14.240165614652458,7.5212882733505e-12,0.23934193501142248,20579.280789545748,-1.0410512056158225,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX20-55W,Sunflare Co,Thin Film,0,55.0,49.5,0.59,,,20.0,7.2,12.0,6.17,8.9,-0.00021600000000000002,-0.03924,44.9,0.46324637233845795,7.359692907827804,3.617011718649773e-11,0.2870372782067004,12.94151675529081,-4.611178087094509,-0.434,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX20-60W,Sunflare Co,Thin Film,0,60.0,54.1,0.59,,,20.0,7.4,12.5,6.3,9.5,-0.00022200000000000003,-0.040875,44.9,0.4915885518304221,7.549044012730363,5.915506534782249e-11,0.24785754333367327,12.30606862143509,-0.9692348600528254,-0.434,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-160W,Sunflare Co,Thin Film,0,160.0,138.5,1.64,,,60.0,7.19,35.11,5.8,27.63,-0.00084842,-0.11003474,55.89,1.3547930155673433,7.360439283371841,3.2750926765223326e-11,0.5661284782483442,23.882192491530574,-0.8311132586663781,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-160W-M20-A,Sunflare Co,Thin Film,0,160.0,138.5,1.64,,,60.0,7.19,35.11,5.8,27.63,-0.00084842,-0.11003474,55.89,1.3547930155673433,7.360439283371841,3.2750926765223326e-11,0.5661284782483442,23.882192491530574,-0.8311132586663781,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-165W,Sunflare Co,Thin Film,0,165.0,142.9,1.64,,,60.0,7.28,35.42,6.0,27.5,-0.00085904,-0.11100628000000001,55.89,1.3357456502912073,7.45298086990955,1.8698083690794458e-11,0.6398004703264781,26.926373084647476,-5.33589927898945,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-165W-M20-A,Sunflare Co,Thin Film,0,165.0,142.9,1.64,,,60.0,7.28,35.42,6.0,27.5,-0.00085904,-0.11100628000000001,55.89,1.3357456502912073,7.45298086990955,1.8698083690794458e-11,0.6398004703264781,26.926373084647476,-5.33589927898945,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-170W,Sunflare Co,Thin Film,0,170.0,147.3,1.64,,,60.0,7.38,35.74,6.21,27.37,-0.00087084,-0.11200916000000002,55.89,1.3201405335283567,7.548285173684681,1.1176479505993276e-11,0.707240153255169,31.015402215562403,-9.326972269868527,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-170W-M20-A,Sunflare Co,Thin Film,0,170.0,147.3,1.64,,,60.0,7.38,35.74,6.21,27.37,-0.00087084,-0.11200916000000002,55.89,1.3201405335283567,7.548285173684681,1.1176479505993276e-11,0.707240153255169,31.015402215562403,-9.326972269868527,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-175W,Sunflare Co,Thin Film,0,175.0,173.8,1.64,,,60.0,7.42,35.95,6.22,28.18,0.00040068000000000005,-0.10741860000000002,44.01,1.1311198496458577,7.590178151273037,9.990000003794545e-14,0.6634797257942818,28.928622909610905,-35.72886962456503,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-175W-M20,Sunflare Co,Thin Film,0,175.0,173.8,1.64,,,60.0,7.42,35.95,6.22,28.18,0.00040068000000000005,-0.10741860000000002,44.01,1.1311198496458577,7.590178151273037,9.990000003794545e-14,0.6634797257942818,28.928622909610905,-35.72886962456503,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-175W-M20-A,Sunflare Co,Thin Film,0,175.0,151.7,1.64,,,60.0,7.42,35.95,6.22,28.18,-0.00087556,-0.11266730000000001,55.89,1.349187398310873,7.562368291214516,1.7095160518215133e-11,0.5842510861128435,30.45020091476758,-6.199932139606093,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-177W,Sunflare Co,Thin Film,0,177.0,153.5,1.64,,,60.0,7.67,36.14,6.49,27.27,-0.0009050600000000001,-0.11326276,55.89,1.3195558345395622,7.855659604031469,8.551635263950071e-12,0.7613781804249813,31.45418033465694,-11.555764261566399,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-180W,Sunflare Co,Thin Film,0,180.0,178.8,1.64,,,60.0,7.43,36.4,6.28,28.68,0.00040122000000000004,-0.1087632,44.01,1.1448877826929882,7.582615552050665,9.990000003991518e-14,0.6412689516506483,31.219808512038448,-35.759198225186076,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-180W-M20,Sunflare Co,Thin Film,0,180.0,178.8,1.64,,,60.0,7.43,36.4,6.28,28.68,0.00040122000000000004,-0.1087632,44.01,1.1448877826929882,7.582615552050665,9.990000003991518e-14,0.6412689516506483,31.219808512038448,-35.759198225186076,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-180W-M20-A,Sunflare Co,Thin Film,0,180.0,156.2,1.64,,,60.0,7.43,36.4,6.28,28.68,-0.00087674,-0.1140776,55.89,1.3633702957618894,7.556861310393078,1.6393184349179016e-11,0.5625051603005145,32.94474365971579,-6.547460780514106,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-185W,Sunflare Co,Thin Film,0,185.0,183.8,1.64,,,60.0,7.53,36.63,6.53,28.33,0.00040662000000000006,-0.10945044000000001,44.01,1.1504268593959481,7.669021925048886,9.990000002840577e-14,0.7159547255829326,38.77905648462968,-35.93080883335304,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-185W-M20,Sunflare Co,Thin Film,0,185.0,183.8,1.64,,,60.0,7.53,36.63,6.53,28.33,0.00040662000000000006,-0.10945044000000001,44.01,1.1504268593959481,7.669021925048886,9.990000002840577e-14,0.7159547255829326,38.77905648462968,-35.93080883335304,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-185W-M20-A,Sunflare Co,Thin Film,0,185.0,160.6,1.64,,,60.0,7.53,36.63,6.53,28.33,-0.0008885400000000001,-0.11479842000000001,55.89,1.338109498720532,7.648836846749479,8.741214723125518e-12,0.6526024673549959,41.35162390670266,-11.332731245355076,-0.3847,Y,2025.7.3,6/23/2025,4.0,first_pass +Sunflare Co FLEX60-190W,Sunflare Co,Thin Film,0,190.0,188.8,1.64,,,60.0,7.54,36.93,6.49,29.26,0.00040716000000000005,-0.11034684000000002,44.01,1.1602376472753686,7.665220264750249,9.990000004745235e-14,0.6059546584887533,36.48689079461314,-35.896732447136074,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-190W-M20,Sunflare Co,Thin Film,0,190.0,188.8,1.64,,,60.0,7.54,36.93,6.49,29.26,0.00040716000000000005,-0.11034684000000002,44.01,1.1602376472753686,7.665220264750249,9.990000004745235e-14,0.6059546584887533,36.48689079461314,-35.896732447136074,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-195W,Sunflare Co,Thin Film,0,195.0,193.7,1.64,,,60.0,7.6,37.6,6.53,29.86,0.0004104,-0.1123488,44.01,1.1810832831367897,7.725923440994061,9.990000004434475e-14,0.6012318084011555,36.286824025547716,-35.93287429483072,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sunflare Co FLEX60-195W-M20,Sunflare Co,Thin Film,0,195.0,193.7,1.64,,,60.0,7.6,37.6,6.53,29.86,0.0004104,-0.1123488,44.01,1.1810832831367897,7.725923440994061,9.990000004434475e-14,0.6012318084011555,36.286824025547716,-35.93287429483072,-0.0307,Y,2025.7.3,6/23/2025,2.0,first_pass +Sungen Power LLC SS-380-54IIMJ,Sungen Power LLC,Mono-c-Si,0,380.0,356.9,1.95,,,54.0,13.41,36.05,12.65,30.04,0.0045996299999999995,-0.0917112,43.2,1.3144144046205137,13.421949279838419,1.620410372616007e-11,0.15091717019573297,169.36579357439655,8.560520057622607,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-385-54IIMJ,Sungen Power LLC,Mono-c-Si,0,385.0,361.7,1.95,,,54.0,13.53,36.19,12.77,30.16,0.00464079,-0.09206736,43.2,1.319257351830227,13.541546812603684,1.6270436450530472e-11,0.14988795986600165,175.63150158245568,8.515607487185731,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-390-54IIMJ,Sungen Power LLC,Mono-c-Si,0,390.0,366.5,1.95,,,54.0,13.65,36.3,12.88,30.3,0.004641000000000001,-0.09220199999999999,43.2,1.3233501211423422,13.66168609826632,1.6434957795136353e-11,0.14490223892170634,169.253717113251,8.704343046888456,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-395-54IIMJ,Sungen Power LLC,Mono-c-Si,0,395.0,371.3,1.95,,,54.0,13.76,36.51,12.98,30.42,0.0046784,-0.0927354,43.2,1.3299914775301542,13.772338579590564,1.62216201847557e-11,0.14944137900666563,166.65721882084253,8.519105180466173,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-400-54IIMJ,Sungen Power LLC,Mono-c-Si,0,400.0,376.1,1.95,,,54.0,13.89,36.64,13.1,30.54,0.0047226,-0.0930656,43.2,1.3351081911901366,13.902583866572828,1.6499186181059784e-11,0.1475368763009942,162.8503615390451,8.58676889838309,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-405-54IIMJ,Sungen Power LLC,Mono-c-Si,0,405.0,381.0,1.95,,,54.0,14.0,36.8,13.21,30.67,0.004760000000000001,-0.093472,43.2,1.3163115492010995,14.013307196291429,9.949294028127496e-12,0.1514431205772778,159.32760350115683,4.146917311864383,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-410-54IIMJ,Sungen Power LLC,Mono-c-Si,0,410.0,385.8,1.95,,,54.0,14.12,36.93,13.32,30.78,0.0048008,-0.0938022,43.2,1.3454899690916204,14.13257877833722,1.6713712781191022e-11,0.14644251320959295,164.3854626651343,8.554825940719697,-0.343,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sungen Power LLC SS-415-54IIMJ,Sungen Power LLC,Mono-c-Si,0,415.0,390.6,1.95,,,54.0,14.21,37.05,13.43,30.89,0.0048314000000000005,-0.094107,43.2,1.3488805801029278,14.220801491084982,1.6523383180270388e-11,0.1452320669210373,191.06136970706774,8.389448834370961,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-425-60IIMJ,Sungen Power LLC,Mono-c-Si,0,425.0,399.2,2.17,,,60.0,13.37,40.2,12.66,33.58,0.0045859099999999995,-0.1022688,43.2,1.464873184835298,13.378230472009555,1.5966440865299115e-11,0.1616058362475443,262.5207937801001,8.440071923504128,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-430-60IIMJ,Sungen Power LLC,Mono-c-Si,0,430.0,404.0,2.17,,,60.0,13.46,40.35,12.75,33.74,0.004616780000000001,-0.10265040000000002,43.2,1.470825847954186,13.467864262773837,1.6226108127154424e-11,0.15803143356584257,270.4771154818021,8.521662419822343,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-435-60IIMJ,Sungen Power LLC,Mono-c-Si,0,435.0,408.8,2.17,,,60.0,13.55,40.49,12.83,33.91,0.00464765,-0.10300656000000001,43.2,1.4773557276873142,13.558117257101062,1.6762623025698606e-11,0.15277394782257747,255.0229690431799,8.75216633729043,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-440-60IIMJ,Sungen Power LLC,Mono-c-Si,0,440.0,413.6,2.17,,,60.0,13.66,40.63,12.91,34.08,0.004685379999999999,-0.10336272000000002,43.2,1.484923964841019,13.669551561264228,1.7642426700266813e-11,0.1472488603234414,210.58540978271938,9.142152994228518,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-445-60IIMJ,Sungen Power LLC,Mono-c-Si,0,445.0,418.4,2.17,,,60.0,13.72,40.88,13.0,34.23,0.00470596,-0.10399872000000002,43.2,1.49095119803934,13.727643685757942,1.6790106732464452e-11,0.15296833164015997,274.5698422097531,8.653317730045071,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-450-60IIMJ,Sungen Power LLC,Mono-c-Si,0,450.0,423.2,2.17,,,60.0,13.8,41.13,13.09,34.38,0.0047334,-0.10463472000000001,43.2,1.4980244789010417,13.806869342088701,1.629102574108067e-11,0.15827849880993924,317.96988292720323,8.330732273250323,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-455-60IIMJ,Sungen Power LLC,Mono-c-Si,0,455.0,428.1,2.17,,,60.0,13.92,41.38,13.16,34.56,0.004774559999999999,-0.10527072000000003,43.2,1.508877876744178,13.930028772429255,1.6899138733104904e-11,0.1601688458237907,222.3153793049293,8.592329123416944,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-460-60IIMJ,Sungen Power LLC,Mono-c-Si,0,460.0,432.9,2.17,,,60.0,14.04,41.61,13.21,34.82,0.00481572,-0.10585584,43.2,1.5222224426422633,14.054082619954023,1.8529443179060027e-11,0.15346584856537562,153.00139687310346,9.353642732178765,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-510-72IIMJ,Sungen Power LLC,Mono-c-Si,0,510.0,479.1,2.58,,,72.0,13.36,48.22,12.68,40.21,0.00458248,-0.12267168,43.2,1.7537040885230069,13.366265787344323,1.5168042683081612e-11,0.20042747134672,427.3542804278994,7.984545647951838,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-515-72IIMJ,Sungen Power LLC,Mono-c-Si,0,515.0,483.9,2.58,,,72.0,13.45,48.37,12.77,40.32,0.00461335,-0.12305328,43.2,1.7585398340084506,13.455993971989827,1.512989720383451e-11,0.20108238328017053,451.2129997600587,7.901824481434026,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-520-72IIMJ,Sungen Power LLC,Mono-c-Si,0,520.0,488.7,2.58,,,72.0,13.52,48.52,12.84,40.51,0.004637359999999999,-0.12343488000000001,43.2,1.7651583930868548,13.525710405261979,1.5489934580896197e-11,0.19488655069299976,461.41492088197583,8.061792864469373,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-525-72IIMJ,Sungen Power LLC,Mono-c-Si,0,525.0,493.5,2.58,,,72.0,13.59,48.67,12.9,40.71,0.00466137,-0.12381648,43.2,1.7204262246007964,13.597476666058927,6.9681693300241555e-12,0.19689879320771475,357.89409182144243,1.2209560359423008,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-530-72IIMJ,Sungen Power LLC,Mono-c-Si,0,530.0,498.4,2.58,,,72.0,13.67,48.82,12.96,40.89,0.00468881,-0.12419808000000002,43.2,1.7803034624435445,13.677106764429887,1.6680256323024013e-11,0.18237071290371962,350.79362596372744,8.625071293599094,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-535-72IIMJ,Sungen Power LLC,Mono-c-Si,0,535.0,503.2,2.58,,,72.0,13.72,49.06,13.02,41.08,0.00470596,-0.12480864000000001,43.2,1.788000153629866,13.726323307560063,1.6491583317161108e-11,0.1836516778235474,398.4783341080901,8.4880570417902,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-540-72IIMJ,Sungen Power LLC,Mono-c-Si,0,540.0,508.0,2.58,,,72.0,13.8,49.35,13.09,41.25,0.0047334,-0.12554640000000003,43.2,1.7973897100123073,13.80687089930436,1.6285803923989024e-11,0.18999723388350465,381.60388273112187,8.327904995313476,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-545-72IIMJ,Sungen Power LLC,Mono-c-Si,0,545.0,512.8,2.58,,,72.0,13.87,49.64,13.16,41.42,0.004757409999999999,-0.12628416,43.2,1.806163969935546,13.87676092852027,1.5937262441007206e-11,0.19647001723473773,403.05694010345417,8.091516679347983,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Sungen Power LLC SS-550-72IIMJ,Sungen Power LLC,Mono-c-Si,0,550.0,517.7,2.58,,,72.0,13.94,49.9,13.23,41.6,0.0047396,-0.126746,43.2,1.8130619959474517,13.946626152882528,1.541309462469945e-11,0.19998332139287878,420.7216220483757,7.9276238329371065,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF500J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,500.0,465.8,2.69,,,72.0,13.36,48.74,12.11,41.35,0.002672,-0.12477440000000002,44.94,1.8085804528368923,13.391966765270118,2.476949838353975e-11,0.1348629451437751,56.36381830515413,12.080229928004771,-0.3463,N,2025.7.3,6/23/2025,4.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH500J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,500.0,468.0,2.69,,,72.0,13.32,48.7,12.07,41.3,0.0034898400000000006,-0.125646,43.59,1.823374120710584,13.351467641286764,3.141268768562427e-11,0.13352970805483155,56.5220538144197,13.298308296967654,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF505J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,505.0,470.6,2.69,,,72.0,13.41,48.94,12.16,41.58,0.002682,-0.1252864,44.94,1.817014488684228,13.440545158052778,2.52467951360473e-11,0.12928018240064618,56.75685963983763,12.217971176220903,-0.3463,N,2025.7.3,6/23/2025,4.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH505J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,505.0,472.8,2.69,,,72.0,13.38,48.9,12.13,41.54,0.00350556,-0.126162,43.59,1.8320481861716464,13.409810424969905,3.211740460533586e-11,0.1268862133014003,56.95113499649231,13.458757307247808,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF510J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,510.0,475.4,2.69,,,72.0,13.46,49.14,12.21,41.81,0.0026920000000000004,-0.1257984,44.94,1.8254461845249739,13.48914372385492,2.572842607574859e-11,0.12374489655327217,57.15145799791629,12.354283352488277,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH510J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,510.0,477.6,2.69,,,72.0,13.44,49.1,12.19,41.78,0.00352128,-0.126678,43.59,1.8407196180034258,13.46817900162611,3.2830569162839464e-11,0.12031031745983856,57.38211290667944,13.617550695541972,-0.3477,N,2025.7.3,6/23/2025,4.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF515J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,515.0,480.1,2.69,,,72.0,13.51,49.34,12.26,42.06,0.002702,-0.12631040000000002,44.94,1.8343355704934052,13.537324282591012,2.639075050922278e-11,0.11638014093918835,57.542067240417175,12.55025215310789,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH515J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,515.0,482.4,2.69,,,72.0,13.5,49.3,12.25,42.02,0.003537,-0.127194,43.59,1.8493882969224449,13.526572874324014,3.3552096520218487e-11,0.11380101535001233,57.81511217057882,13.774694173864907,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF520J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,520.0,484.9,2.69,,,72.0,13.56,49.54,12.31,42.26,0.002712,-0.1268224,44.94,1.8420729809531635,13.58661740038044,2.6615749203551406e-11,0.11374848664904164,57.948163942999194,12.592334312824029,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH520J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,520.0,487.2,2.69,,,72.0,13.56,49.5,12.31,42.26,0.00355272,-0.12771,43.59,1.858054518357907,13.584991678969397,3.428208888829417e-11,0.10735724956948958,58.249960247387804,13.930244649386552,-0.3477,N,2025.7.3,6/23/2025,4.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF525J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,525.0,489.7,2.69,,,72.0,13.61,49.74,12.36,42.54,0.002722,-0.12733440000000001,44.94,1.8516455527478561,13.63419404999079,2.7561728759781063e-11,0.10369744315392525,58.33344163957481,12.875748394428769,-0.3463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH525J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,525.0,492.0,2.69,,,72.0,13.62,49.7,12.37,42.5,0.00356844,-0.128226,43.59,1.86671797177856,13.643434896379084,3.502036990396022e-11,0.10097809039848922,58.686907388821126,14.084182664415849,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMF530J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,530.0,494.5,2.69,,,72.0,13.66,49.94,12.41,42.76,0.002732,-0.1278464,44.94,1.8598380172184654,13.683090631518828,2.7972709255056632e-11,0.09928803612545864,58.73700657044855,12.975880599110761,-0.3463,N,2025.7.3,6/23/2025,4.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH530J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,530.0,496.8,2.69,,,72.0,13.68,49.86,12.43,42.74,0.0035841600000000003,-0.1286388,43.59,1.8746716635546528,13.70117161264795,3.617096332762814e-11,0.09141544611729778,59.06792855022339,14.34038982984247,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Sunman (Zhenjiang) Co Ltd SMH535J-12X12UW,Sunman (Zhenjiang) Co Ltd,Mono-c-Si,0,535.0,501.6,2.69,,,72.0,13.74,50.1,12.49,42.98,0.00359988,-0.129258,43.59,1.8840375874694417,13.760393097090128,3.652213998507455e-11,0.08840957198258485,59.56660313272268,14.38742555675753,-0.3477,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-180PB203,Sunny International Power,Multi-c-Si,0,180.0,161.9,1.455336,1.476,0.986,54.0,7.7,32.4,6.98,25.8,0.0064449,-0.11446920000000001,45.7,1.3908433793800699,7.735306347767499,5.598812602139329e-10,0.3661862206690358,79.86196142949323,8.062739082313604,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-180SB105,Sunny International Power,Mono-c-Si,0,180.0,161.9,1.262348,1.574,0.802,72.0,5.58,43.6,5.05,35.8,0.0036549000000000004,-0.1611456,45.7,1.9136344622465473,5.5970041241180075,6.728448857397415e-10,0.42220548885138426,138.54914475506618,7.825696494338717,-0.4571,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-190PB203,Sunny International Power,Multi-c-Si,0,190.0,171.1,1.455336,1.476,0.986,54.0,7.82,32.8,7.28,26.2,0.00654534,-0.11588239999999998,45.7,1.3900454147157717,7.832518987203062,4.343061736758332e-10,0.3524540252186712,220.16086695856063,5.646422868009951,-0.442,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-190SB105,Sunny International Power,Mono-c-Si,0,190.0,171.1,1.262348,1.574,0.802,72.0,5.73,43.8,5.23,36.5,0.0037531500000000002,-0.1618848,45.7,1.9301785402038325,5.740361365311643,7.638618434432231e-10,0.29466918611031806,162.95676869640332,8.690059481650776,-0.4571,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-200PB203,Sunny International Power,Multi-c-Si,0,200.0,180.4,1.455336,1.476,0.986,54.0,8.0,32.8,7.64,26.2,0.006696,-0.11588239999999998,45.7,1.38651580479085,8.000002410578318,4.25829492546915e-10,0.30107207054621943,999996.518873624,5.237611630236665,-0.442,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-200PB204,Sunny International Power,Multi-c-Si,0,200.0,180.0,1.6111239999999998,1.634,0.986,60.0,7.7,36.0,6.94,28.85,0.0069069,-0.12556799999999999,45.0,1.5824464130106672,7.735882815110418,9.595284191048933e-10,0.367267319905586,78.81094977031435,14.333118859637514,-0.4561,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-200SB105,Sunny International Power,Mono-c-Si,0,200.0,180.4,1.262348,1.574,0.802,72.0,5.96,43.8,5.43,36.9,0.0039038000000000002,-0.1618848,45.7,1.9453774321703712,5.967841660625223,9.454669498686813e-10,0.19489590071234042,148.12929788218534,10.252665250992118,-0.4571,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-210PB203,Sunny International Power,Multi-c-Si,0,210.0,189.6,1.455336,1.476,0.986,54.0,8.1,33.2,7.92,26.6,0.0067797,-0.11729560000000001,45.7,1.4228873990721025,8.100001211037783,5.958828301653597e-10,0.14941205446213943,999999.1603142637,8.042458847678413,-0.442,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-210PB204,Sunny International Power,Multi-c-Si,0,210.0,189.2,1.6111239999999998,1.634,0.986,60.0,7.82,36.44,7.25,29.0,0.0070145400000000005,-0.12710272,45.0,1.5699040446004224,7.835448270898301,6.358414375990697e-10,0.4019812504834038,203.48518150437687,10.332764876527547,-0.4561,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-220PB203,Sunny International Power,Multi-c-Si,0,220.0,198.9,1.455336,1.476,0.986,54.0,8.25,33.4,8.22,26.8,0.00690525,-0.1180022,45.7,1.4438519098878229,8.25000119388385,7.41491823966589e-10,0.14459230714847177,999990.3908772103,9.818153619544507,-0.442,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-220PB204,Sunny International Power,Multi-c-Si,0,220.0,198.4,1.6111239999999998,1.634,0.986,60.0,8.0,36.44,7.6,29.0,0.007176,-0.12710272,45.0,1.5603632526150144,8.000002914162376,5.764692954121888e-10,0.3638767679757497,999999.9426658887,9.198418257694716,-0.4561,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-230PB204,Sunny International Power,Multi-c-Si,0,230.0,207.7,1.6111239999999998,1.634,0.986,60.0,8.1,36.89,7.89,29.2,0.007265700000000001,-0.12867232,45.0,1.5955905222981026,8.100001969152439,7.372403843427132e-10,0.24288384595021978,999999.8446054938,11.29667446592436,-0.4561,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-230PB206,Sunny International Power,Multi-c-Si,0,230.0,206.9,1.7688840000000001,1.794,0.986,66.0,8.0,40.5,7.2,32.0,0.006848,-0.147258,45.3,1.7643337710501652,8.045180293186798,8.119353196444011e-10,0.4741476263627257,83.9565496446159,7.847794935778611,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-240PB204,Sunny International Power,Multi-c-Si,0,240.0,216.9,1.6111239999999998,1.634,0.986,60.0,8.4,37.0,8.16,29.4,0.0075348,-0.129056,45.0,1.6011381694101805,8.400001965182655,7.733154588751626e-10,0.2337264017598993,999990.5512157824,11.400232478899339,-0.4561,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-240PB205,Sunny International Power,Multi-c-Si,0,240.0,216.4,1.9226999999999999,1.95,0.986,72.0,7.7,43.2,6.89,34.4,0.0069608,-0.153792,45.1,1.8870976463519493,7.745219898878172,8.249872864596943e-10,0.4816413563179677,82.01342662959225,10.628283144144362,-0.4463,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-240PB206,Sunny International Power,Multi-c-Si,0,240.0,216.1,1.7688840000000001,1.794,0.986,66.0,8.2,40.5,7.46,32.2,0.007019199999999999,-0.147258,45.3,1.7603169151659526,8.233648722717877,7.99537243322982e-10,0.4307140421302499,104.96254813109469,7.4706225355212785,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-250PB205,Sunny International Power,Multi-c-Si,0,250.0,225.6,1.9226999999999999,1.95,0.986,72.0,7.8,43.4,7.23,34.6,0.0070512,-0.154504,45.1,1.859674881807489,7.815776234846145,5.587705338696767e-10,0.473333664931895,234.02310148108694,6.961006611093276,-0.4463,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-250PB206,Sunny International Power,Multi-c-Si,0,250.0,225.4,1.7688840000000001,1.794,0.986,66.0,8.33,40.9,7.74,32.3,0.00713048,-0.1487124,45.3,1.7497164938248033,8.345075096085957,5.771593120975004e-10,0.46261984642497633,255.62852047620694,4.461274824758228,-0.4547,N,2025.7.3,6/23/2025,4.0,first_pass +Sunny International Power SPM-260PB205,Sunny International Power,Multi-c-Si,0,260.0,234.9,1.9226999999999999,1.95,0.986,72.0,7.9,43.6,7.47,34.8,0.0071416,-0.155216,45.1,1.8509708952618524,7.911177768772657,4.65953885144319e-10,0.4627666170425365,999999.9827793491,5.217621782458113,-0.4463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-260PB206,Sunny International Power,Multi-c-Si,0,260.0,234.6,1.7688840000000001,1.794,0.986,66.0,8.51,41.3,8.03,32.4,0.007284559999999999,-0.1501668,45.3,1.7466863033734603,8.52252008314625,4.5895676296823007e-10,0.48819371902412656,999999.9807082014,2.302915807757977,-0.4547,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-270PB205,Sunny International Power,Multi-c-Si,0,270.0,244.1,1.9226999999999999,1.95,0.986,72.0,8.1,43.7,7.72,35.0,0.0073224,-0.15557200000000002,45.1,1.8670522421434539,8.100003137167668,5.539090827352444e-10,0.38700630849472617,999999.5703380449,6.502609740134334,-0.4463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-270PB206,Sunny International Power,Multi-c-Si,0,270.0,243.9,1.7688840000000001,1.794,0.986,66.0,8.69,41.7,8.32,32.5,0.007438639999999999,-0.1516212,45.3,1.7726527673942856,8.690280814146867,5.278444888350129e-10,0.4319355527166484,13366.74626906343,3.308018654147875,-0.4547,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-280PB205,Sunny International Power,Multi-c-Si,0,280.0,253.4,1.9226999999999999,1.95,0.986,72.0,8.3,43.8,7.95,35.2,0.0075032,-0.15592799999999998,45.1,1.8797859994527581,8.300235165557803,6.303837735193403e-10,0.3312022912446581,11689.65148570667,7.417751432481826,-0.4463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunny International Power SPM-290PB205,Sunny International Power,Multi-c-Si,0,290.0,262.7,1.9226999999999999,1.95,0.986,72.0,8.5,43.9,8.2,35.4,0.007684,-0.156284,45.1,1.893410577574912,8.500002249170123,7.244469893754617e-10,0.26440824649051853,999994.4476768373,8.430291933063213,-0.4463,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP390M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,390.0,362.4,1.96,,,54.0,13.6,36.96,12.85,30.36,0.0075616,-0.09616992,45.97,1.3758350460253685,13.610314870881211,2.899078036469291e-11,0.18516236190985774,244.13375485180055,10.818817799898001,-0.3494,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP395M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,395.0,367.1,1.96,,,54.0,13.67,37.04,12.97,30.46,0.00760052,-0.09637807999999999,45.97,1.376902085236951,13.675536338618953,2.820794274904941e-11,0.1816416054378837,448.4987245661716,10.509210353775545,-0.3494,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP400M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,400.0,371.9,1.96,,,54.0,13.74,37.12,13.09,30.56,0.007639439999999999,-0.09658623999999999,45.97,1.3780138846367416,13.740924430569827,2.746904602387437e-11,0.1781721499290388,2648.2089956460964,10.208148875468883,-0.3494,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP405M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,405.0,376.7,1.96,,,54.0,13.81,37.2,13.21,30.66,0.0076783599999999995,-0.0967944,45.97,1.3830129021111863,13.810002302665044,2.874933871111743e-11,0.16672992255382896,999999.3339246172,10.567301738860944,-0.3494,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP410M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,410.0,381.5,1.96,,,54.0,13.88,37.28,13.33,30.76,0.00771728,-0.09700256,45.97,1.389296802748759,13.880578950418087,3.0788273360169234e-11,0.17007422275634757,4077.431674929431,11.14057440831859,-0.3494,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP415M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,415.0,386.3,1.96,,,54.0,13.95,37.36,13.45,30.86,0.007756199999999999,-0.09721071999999999,45.97,1.395001721736442,13.950002294711656,3.2627929103523923e-11,0.13802690784549976,838950.0271179718,11.617207889511818,-0.3494,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP420M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,420.0,391.0,1.96,,,54.0,14.02,37.44,13.57,30.96,0.007795119999999999,-0.09741888,45.97,1.4010072249040038,14.020002040063636,3.473931507039108e-11,0.12246400195380538,841460.8756353843,12.140749135687567,-0.3494,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP425M-54HB,Sunpal Power Co Ltd,Mono-c-Si,0,425.0,395.8,1.96,,,54.0,14.09,37.52,13.69,31.06,0.007834039999999999,-0.09762704,45.97,1.4070276073734542,14.090001766553506,3.697862236191489e-11,0.10579882485590222,843687.2211272764,12.664651669156314,-0.3494,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP435M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,435.0,404.3,2.17,,,72.0,11.23,49.36,10.69,40.72,0.0056486900000000005,-0.13416048,46.15,1.822185955585536,11.231903433684929,1.9274918446904492e-11,0.2835200384287258,1672.7296355981837,4.245447570861312,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP440M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,440.0,409.1,2.17,,,72.0,11.3,49.56,10.76,40.92,0.0056838999999999995,-0.13470408,46.15,1.8300915556163468,11.301672817855525,1.9551098755296272e-11,0.27917548754280574,1885.8497698895221,4.312271521215963,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP445M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,445.0,413.9,2.17,,,72.0,11.37,49.76,10.83,41.1,0.0057191099999999995,-0.13524767999999998,46.15,1.8375455463241273,11.371423193984072,1.969853844492832e-11,0.27701136759015416,2213.0640828981886,4.322426821886855,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP450M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,450.0,418.7,2.17,,,72.0,11.44,50.0,10.9,41.32,0.005754319999999999,-0.1359,46.15,1.8466342967812184,11.44118607013279,1.9891670770114692e-11,0.2743616698676184,2646.300289006104,4.351985203455336,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP455M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,455.0,423.5,2.17,,,72.0,11.51,50.16,10.96,41.52,0.005789529999999999,-0.13633487999999996,46.15,1.8546072603763148,11.511816289341214,2.0607468439959143e-11,0.2664243929436959,1688.3570476635282,4.603188581317777,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP460M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,460.0,428.2,2.17,,,72.0,11.58,50.36,11.03,41.72,0.00582474,-0.13687848,46.15,1.8625102550950634,11.581598113931946,2.0892094589845937e-11,0.262296720126088,1900.6130421860778,4.667198250664848,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP465M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,465.0,433.0,2.17,,,72.0,11.65,50.56,11.1,41.92,0.00585995,-0.13742208,46.15,1.8704172832203942,11.651385739931237,2.117971995527792e-11,0.2582206412274872,2170.8767901897804,4.731190676974564,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP470M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,470.0,437.8,2.17,,,72.0,11.72,50.76,11.17,42.12,0.00589516,-0.13796567999999998,46.15,1.8783252564693258,11.721179128980662,2.14694157790682e-11,0.25419578794438435,2526.5894514394377,4.794788096130882,-0.3453,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP520M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,520.0,488.3,2.58,,,72.0,13.54,49.18,12.84,40.5,0.0073116,-0.12762210000000002,45.8,1.7369468281253841,13.549017106702301,6.77836670762084e-12,0.25436831966923656,381.9570044279533,-1.2538569768235122,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP525M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,525.0,493.1,2.58,,,72.0,13.61,49.28,12.94,40.59,0.0073494,-0.1278816,45.8,1.7385808967687757,13.615974142383237,6.626034618590973e-12,0.2529004151481991,576.1454040590814,-1.4903173414226656,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP530M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,530.0,497.9,2.58,,,72.0,13.68,49.38,13.03,40.68,0.0073872,-0.1281411,45.8,1.7408486948289992,13.683863758754358,6.538461178035481e-12,0.2514458490572988,890.2676046731551,-1.6467041211276707,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP535M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,535.0,502.8,2.58,,,72.0,13.75,49.48,13.13,40.77,0.007425,-0.1284006,45.8,1.7425362768460475,13.750855630971463,6.397034314962132e-12,0.2500042718351135,4017.571762856427,-1.8748147296200355,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP540M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,540.0,507.6,2.58,,,72.0,13.82,49.58,13.22,40.86,0.007462800000000001,-0.1286601,45.8,1.7463880841778427,13.820003388729836,6.469574725392474e-12,0.24520184807193485,999999.5168418075,-1.827719173971239,-0.3041,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP545M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,545.0,512.4,2.58,,,72.0,13.89,49.68,13.31,40.95,0.0075006,-0.12891960000000002,45.8,1.7510497908965834,13.890006579308128,6.623553367415629e-12,0.24658544438000388,520585.5523530979,-1.6785526712102044,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP550M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,550.0,517.2,2.58,,,72.0,13.96,49.78,13.41,41.04,0.0075384,-0.12917910000000002,45.8,1.7562713551620732,13.960006544073224,6.8419413580703224e-12,0.24467699433575815,521955.07684920117,-1.4568107569584359,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP555M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,555.0,522.0,2.58,,,72.0,14.03,49.88,13.5,41.13,0.0075762,-0.12943860000000001,45.8,1.766788846651879,14.030006498158833,7.642233708732472e-12,0.24290126237662948,524445.2116336597,-5.901144323911417,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP560M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,560.0,526.8,2.58,,,72.0,14.1,49.98,13.59,41.22,0.007613999999999999,-0.12969809999999998,45.8,1.7666154720293272,14.100003332388654,7.284919198861686e-12,0.21306360287398976,901523.2024227856,-1.0288544008686449,-0.3041,N,2025.7.3,6/23/2025,2.0,first_pass +Sunpal Power Co Ltd SP565M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,565.0,531.7,2.58,,,72.0,14.17,50.08,13.68,41.31,0.007651799999999999,-0.1299576,45.8,1.770586338361078,14.170101757186659,7.371592150293556e-12,0.23955248005654828,33358.437547764916,-0.9726277934142357,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP570M-72HB,Sunpal Power Co Ltd,Mono-c-Si,0,570.0,536.5,2.58,,,72.0,14.24,50.18,13.77,41.4,0.0076895999999999996,-0.1302171,45.8,1.775302838593407,14.240097535771929,7.548745268314496e-12,0.23789435723544988,34732.05748216813,-0.8195086427981819,-0.3041,N,2025.7.3,6/23/2025,4.0,first_pass +Sunpal Power Co Ltd SP630M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,630.0,586.3,3.11,,,66.0,18.23,44.5,17.22,36.6,0.01190419,-0.127181,45.57,1.686153071939959,18.242748921637606,6.234030502063008e-11,0.15961548281030924,228.23815220246084,4.625865390650471,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP635M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,635.0,591.1,3.11,,,66.0,18.28,44.7,17.26,36.8,0.01193684,-0.12775260000000002,45.57,1.6949392330497282,18.293316709232673,6.366046498813366e-11,0.15750094311514248,216.2033616029617,4.78247431631088,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP640M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,640.0,595.8,3.11,,,66.0,18.33,44.9,17.3,37.0,0.01196949,-0.1283242,45.57,1.7037279363711544,18.343860688292835,6.49982824163885e-11,0.15539574963813482,205.50235917622152,4.938009649788287,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP645M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,645.0,600.6,3.11,,,66.0,18.38,45.1,17.34,37.2,0.01200214,-0.1288958,45.57,1.7125191679015823,18.39438126911446,6.63538380079987e-11,0.1532998368621701,195.9250629049097,5.0924834769180425,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP650M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,650.0,605.4,3.11,,,66.0,18.43,45.3,17.39,37.4,0.012034789999999998,-0.12946739999999998,45.57,1.7208248180307957,18.44407234033531,6.72691124945664e-11,0.15123818312290885,198.070804317598,5.185813511785187,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP655M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,655.0,610.2,3.11,,,66.0,18.48,45.5,17.43,37.6,0.01206744,-0.13003900000000002,45.57,1.7296186225747234,18.49456089285268,6.865128151491958e-11,0.14916239241067367,189.30989264921786,5.338156974791046,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP660M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,660.0,615.0,3.11,,,66.0,18.53,45.7,17.47,37.8,0.01210009,-0.1306106,45.57,1.7384149073632071,18.545027103106435,7.005131050234565e-11,0.1470956722176014,181.38445055795177,5.489485880032229,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP665M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,665.0,619.8,3.11,,,66.0,18.58,45.9,17.5,38.0,0.01213274,-0.1311822,45.57,1.747709100711707,18.596237476872826,7.195502768118844e-11,0.1450077064279791,165.92745599361763,5.700001486752172,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP670M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,670.0,624.6,3.11,,,66.0,18.63,46.1,17.54,38.2,0.012165389999999998,-0.1317538,45.57,1.756512746937639,18.646646885760486,7.340043781165937e-11,0.1429572349688379,159.9874816030966,5.849357663403813,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP675M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,675.0,629.4,3.11,,,66.0,18.68,46.3,17.58,38.4,0.012198039999999999,-0.13232539999999998,45.57,1.7653188496659142,18.697035161036574,7.486406156857734e-11,0.14091566679779458,154.5218557123913,5.997714767435774,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP680M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,680.0,634.2,3.11,,,66.0,18.73,46.5,17.62,38.6,0.01223069,-0.13289700000000002,45.57,1.774127407394392,18.74740264979058,7.63459851087471e-11,0.13888294345819,149.47594762225842,6.145075996239525,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP685M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,685.0,639.0,3.11,,,66.0,18.78,46.7,17.66,38.8,0.012263340000000001,-0.13346860000000002,45.57,1.7829383678715034,18.79774969091503,7.784624695591363e-11,0.1368589983390286,144.8031989810719,6.291477336215857,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Sunpal Power Co Ltd SP690M-66H,Sunpal Power Co Ltd,Mono-c-Si,0,690.0,643.8,3.11,,,66.0,18.83,46.9,17.7,39.0,0.01229599,-0.1340402,45.57,1.791751718461649,18.848076614831317,7.936492024640775e-11,0.13484377545946316,140.46370686812017,6.436927214452706,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM INC SR4-54HTB-400M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,400.0,372.0,1.89,,,54.0,13.51,37.8,13.01,30.8,0.0051338,-0.10206000000000001,45.4,1.4027692191651666,13.510002933179095,2.6782510907377894e-11,0.18259529163980825,840872.0104704337,6.332366153338476,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-405M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,405.0,376.8,1.89,,,54.0,13.56,38.0,13.08,31.0,0.0051528,-0.10260000000000001,45.4,1.4119179269831101,13.560002806471719,2.7782229950372525e-11,0.17450663858984755,843005.207516778,6.616165869741156,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-410M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,410.0,381.6,1.89,,,54.0,13.61,38.2,13.15,31.2,0.0051718,-0.10314000000000002,45.4,1.4211837344803355,13.61010512685717,2.886777594624613e-11,0.20451175183915882,26476.66769542706,6.91568033492818,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-415M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,415.0,386.4,1.89,,,54.0,13.66,38.4,13.22,31.4,0.0051908,-0.10368000000000001,45.4,1.4302322188968428,13.660002544584495,2.986547050906916e-11,0.15782069601461904,847049.2098930675,7.17765245976763,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-420M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,420.0,391.2,1.89,,,54.0,13.71,38.6,13.3,31.6,0.0052098,-0.10422000000000001,45.4,1.4398635706618814,13.710002361281424,3.121966055967716e-11,0.14634218386149941,849502.5626041662,7.530771865234526,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-425M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,425.0,396.0,1.89,,,54.0,13.78,38.8,13.37,31.8,0.0052364,-0.10475999999999999,45.4,1.4481302621319636,13.780002315368309,3.185092551583454e-11,0.14285420861669323,850014.8089668741,7.660566473678222,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-430M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,430.0,400.8,1.89,,,54.0,13.86,39.0,13.44,32.0,0.0052668,-0.1053,45.4,1.455944445425104,13.86000231608369,3.2242601785299216e-11,0.14205011996166672,849875.3441429407,7.716557158245578,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-435M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,435.0,405.6,1.89,,,54.0,13.94,39.2,13.51,32.2,0.005297199999999999,-0.10584000000000002,45.4,1.46375831768907,13.940002316159005,3.263557964777719e-11,0.14121778898278614,849745.2818293225,7.771927091531099,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-440M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,440.0,410.4,1.89,,,54.0,14.01,39.4,13.59,32.4,0.0053238,-0.10638000000000002,45.4,1.47249121581557,14.010002223585339,3.356265827087106e-11,0.13505844909496448,850763.3014181562,7.972432383711045,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM INC SR4-54HTB-445M,SUNPLUS OPTIMUM INC,Mono-c-Si,0,445.0,415.2,1.89,,,54.0,14.09,39.6,13.66,32.6,0.0053542,-0.10692000000000002,45.4,1.480304372324212,14.090002223932759,3.39615200449354e-11,0.13429330599812264,850641.6936707895,8.025838461217143,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR4-72HBD-535M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,535.0,496.2,2.48,,,72.0,13.57,49.7,12.81,41.8,0.0065136000000000005,-0.141148,45.6,1.9227498927859412,13.577415040171022,7.9670688024303e-11,0.15332331635568303,280.5915273775284,10.235753673031953,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM LIMITED SR4-72HBD-540M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,540.0,501.0,2.48,,,72.0,13.66,49.9,12.88,41.9,0.0065568,-0.14171599999999998,45.6,1.9299733100511651,13.668510740234135,7.95523290776367e-11,0.15886555474717273,254.98411017119034,10.168156226883736,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM LIMITED SR4-72HBD-545M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,545.0,505.8,2.48,,,72.0,13.75,50.1,12.95,42.1,0.006600000000000001,-0.142284,45.6,1.9396192502686,13.759256999721536,8.202498990150001e-11,0.1554298937672986,230.86973644806068,10.387217948002972,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM LIMITED SR4-72HBD-550M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,550.0,510.6,2.48,,,72.0,13.82,50.3,13.01,42.3,0.006633600000000001,-0.14285199999999998,45.6,1.948591677938079,13.829484986901782,8.37460567334119e-11,0.15235540655711274,221.9878404914,10.529219893541764,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM LIMITED SR4-72HBD-555M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,555.0,515.4,2.48,,,72.0,13.89,50.5,13.08,42.4,0.0066672,-0.14342,45.6,1.9543681852918589,13.89960432759264,8.204990041694486e-11,0.15826153328177883,228.8814808768673,10.300041386050186,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM LIMITED SR4-72HBD-560M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,560.0,520.2,2.48,,,72.0,13.96,50.7,13.14,42.6,0.0067008,-0.14398799999999998,45.6,1.9633394864061018,13.969839012814433,8.375995669088759e-11,0.15520467162505386,220.21083738835515,10.441139022791631,-0.375,N,2025.7.3,6/23/2025,4.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66HBD-635M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,635.0,589.0,3.03,,,66.0,18.17,44.9,17.13,37.1,0.009085000000000001,-0.130659,44.8,1.7481647675389067,18.183077638171177,1.2584888332042973e-10,0.14476668679186253,201.13806125423113,8.979659609404209,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66HBD-640M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,640.0,593.7,3.03,,,66.0,18.22,45.1,17.17,37.3,0.00911,-0.131241,44.8,1.7571934414837078,18.23353182562932,1.284311913841271e-10,0.14264026079584372,192.05875884389496,9.136203166532956,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66HBD-645M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,645.0,598.5,3.03,,,66.0,18.27,45.3,17.21,37.5,0.009135,-0.13182299999999997,44.8,1.7662249546178512,18.28396358585281,1.310470610114309e-10,0.14052322858249255,183.86104345014567,9.291713040899264,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66HBD-655M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,655.0,608.1,3.03,,,66.0,18.37,45.7,17.3,37.9,0.009185,-0.132987,44.8,1.7837728747056205,18.384047868551093,1.3545122166651805e-10,0.13635773852435915,178.31115957354626,9.536903318556023,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-655M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,655.0,619.0,3.11,,,66.0,17.54,46.6,16.95,38.6,0.0063143999999999995,-0.109976,44.6,1.5935513720685792,17.54000315022305,3.499576496493161e-12,0.1530602020456902,852221.8617745216,0.9390480059130643,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66HBD-660M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,660.0,612.9,3.03,,,66.0,18.42,45.9,17.34,38.1,0.009210000000000001,-0.133569,44.8,1.792810167344329,18.434427829015732,1.381507113596223e-10,0.13427025660091851,171.42275489272203,9.689346871800279,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-660M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,660.0,623.9,3.11,,,66.0,17.62,46.8,17.01,38.8,0.0063432,-0.11044799999999999,44.6,1.6003008537726822,17.620003183613097,3.5097743439146907e-12,0.15388266599279637,851681.9382290832,0.9253379316518971,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66HBD-665M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,665.0,617.7,3.03,,,66.0,18.47,46.1,17.38,38.3,0.009235,-0.134151,44.8,1.8018502481198035,18.484786710130535,1.4088416953653735e-10,0.13219189638699666,165.12019048327463,9.840797635694546,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-665M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,665.0,628.7,3.11,,,66.0,17.7,47.0,17.06,39.0,0.006371999999999999,-0.11092,44.6,1.6066767471275427,17.700003251601025,3.49612188045657e-12,0.15626971662664305,850654.044771839,0.8549469070127792,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66HBD-670M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,670.0,622.5,3.03,,,66.0,18.52,46.3,17.42,38.5,0.009260000000000001,-0.134733,44.8,1.8108931102066885,18.5351248576235,1.4365175593571074e-10,0.13012259740752397,159.33178525907485,9.991259020393926,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-670M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,670.0,633.5,3.11,,,66.0,17.78,47.2,17.12,39.1,0.0064008,-0.111392,44.6,1.6120435316469692,17.780243439753825,3.4187639855192625e-12,0.1625517787212859,11872.220985728762,0.6315038900815524,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66HBD-675M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,675.0,627.2,3.03,,,66.0,18.57,46.5,17.46,38.7,0.009285,-0.135315,44.8,1.8199386869033356,18.585442608518825,1.464535360537832e-10,0.1280622851549329,153.9970849685642,10.140783214678592,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-675M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,675.0,638.4,3.11,,,66.0,17.86,47.4,17.17,39.3,0.0064296,-0.11186399999999999,44.6,1.6184235650384895,17.86024811949688,3.4062609714026386e-12,0.1646370691312359,11850.814404703773,0.5635673548184583,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-680M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,680.0,643.2,3.11,,,66.0,17.94,47.6,17.22,39.5,0.0064583999999999996,-0.112336,44.6,1.6247431437493138,17.94027885683381,3.390211645618074e-12,0.1728401130400062,11119.511207667592,0.4870700158582673,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-685M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,685.0,648.0,3.11,,,66.0,18.01,47.8,17.28,39.7,0.0064836,-0.11280799999999999,44.6,1.6316728229037056,18.01000299060901,3.410493949001233e-12,0.16605111960068422,999996.5157833007,0.5034137663166895,-0.296,N,2025.7.3,6/23/2025,2.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-690M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,690.0,652.9,3.11,,,66.0,18.09,48.0,17.33,39.8,0.0065124,-0.11327999999999999,44.6,1.6364377959937728,18.090003144889454,3.3014901337998935e-12,0.17384561027669276,999999.0272825729,0.19644423187723561,-0.296,N,2025.7.3,6/23/2025,2.0,bootstrapping +SUNPLUS OPTIMUM LIMITED SR5-66NHBD-695M,SUNPLUS OPTIMUM LIMITED,Mono-c-Si,1,695.0,657.7,3.11,,,66.0,18.17,48.2,17.38,40.0,0.0065412000000000005,-0.113752,44.6,1.6441415967089201,18.17144223479843,3.365058109678312e-12,0.1730829198750787,2180.585763893511,0.32279178605592423,-0.296,N,2025.7.3,6/23/2025,4.0,bootstrapping +SunPower SPR-X21-335-BLK,SunPower,Mono-c-Si,0,335.0,313.5,1.63,,,96.0,6.23,67.9,5.85,57.3,0.0021618100000000006,-0.1917496,45.3,2.470910628469247,6.236275801744536,7.088899873461465e-12,0.4797604494656435,476.25908680521326,-2.7075926842245464,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X21-350-BLK,SunPower,Mono-c-Si,0,350.0,327.9,1.63,,,96.0,6.39,68.7,5.99,58.4,0.00221733,-0.1940088,45.3,2.5114804973811085,6.395906757747493,8.22024573546923e-12,0.3913859863742956,423.40596411521165,-1.7245188273650878,-0.3306,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A380-BLK,SunPower,Mono-c-Si,0,380.0,356.8,1.87,,,66.0,10.82,48.01,9.93,38.79,0.0038951999999999997,-0.11426379999999998,46.3,1.6537382900698132,10.870113089093342,2.545756199889082e-12,0.40817898941630504,88.13060072706145,1.6394457827835933,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-380-COM,SunPower,Mono-c-Si,0,380.0,353.3,1.77,,,104.0,6.54,75.2,6.02,63.1,0.0024852,-0.171456,47.0,2.7684630380673925,6.554732520055468,9.984068303064845e-12,0.5613633300743547,249.19811212475517,23.607818817082574,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A385-BLK,SunPower,Mono-c-Si,0,385.0,361.6,1.87,,,66.0,10.84,48.04,9.99,39.04,0.0039023999999999994,-0.1143352,46.3,1.6562829259962526,10.882430633671245,2.6303095091400405e-12,0.3814049533826112,97.43973491352843,1.8831309040867006,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A390,SunPower,Mono-c-Si,0,390.0,365.3,1.87,,,66.0,10.8,48.0,10.0,39.0,0.004104,-0.11375999999999999,46.4,1.6789177714271732,10.835564026006738,3.992966432253507e-12,0.37687880688767134,114.44967221274938,5.86873485735667,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A390-BLK,SunPower,Mono-c-Si,0,390.0,366.4,1.87,,,66.0,10.82,48.07,10.05,39.28,0.0038951999999999997,-0.1144066,46.3,1.6558073714245871,10.851439239797127,2.579190051119466e-12,0.35730726362700355,122.9694044859193,1.7017395191487894,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-390-COM,SunPower,Mono-c-Si,0,390.0,362.8,1.77,,,104.0,6.55,75.3,6.05,64.5,0.002489,-0.171684,47.0,2.7959516493847056,6.5576618062147825,1.262954338717636e-11,0.3132865430448119,267.8254703893034,25.96141033906006,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A395,SunPower,Mono-c-Si,0,395.0,370.1,1.87,,,66.0,10.9,47.5,10.1,39.5,0.004142,-0.11257500000000001,46.4,1.67981738558721,10.926205635679553,5.50314405554919e-12,0.2666713662577417,110.919572049192,8.61637701066954,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A395-BLK,SunPower,Mono-c-Si,0,395.0,371.2,1.87,,,66.0,10.86,48.1,10.12,39.53,0.0039096,-0.11447800000000001,46.3,1.6589474454358428,10.886339868658341,2.69471389376161e-12,0.33061967670637227,136.3153983976308,2.0271646904918974,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-395-BLK,SunPower,Mono-c-Si,0,395.0,374.6,1.9,,,112.0,6.29,81.22,5.71,69.12,0.0035223999999999997,-0.1892426,45.0,2.8531545777938794,6.30597100192259,2.555711278369559e-12,0.5013829226395027,197.46404137349623,8.389707002814086,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-395-BLK-R,SunPower,Mono-c-Si,0,395.0,372.9,1.9,,,112.0,12.58,40.61,11.46,34.46,0.005660999999999999,-0.09502740000000001,46.01,1.4182236294368424,12.612701373646942,4.340890259778537e-12,0.1365902112852406,52.54534188855115,6.62811421788084,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-395-COM-R,SunPower,Mono-c-Si,0,395.0,372.9,1.9,,,112.0,13.04,40.52,11.73,33.67,0.005867999999999999,-0.09481680000000002,46.01,1.4092680472353742,13.103565855662884,3.9462803242960126e-12,0.1993730910601972,40.89971072001414,5.525561027376327,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-395-R,SunPower,Mono-c-Si,0,395.0,372.9,1.9,,,112.0,13.04,40.52,11.73,33.67,0.005867999999999999,-0.09481680000000002,46.01,1.4092680472353742,13.103565855662884,3.9462803242960126e-12,0.1993730910601972,40.89971072001414,5.525561027376327,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-U395-BLK,SunPower,Mono-c-Si,1,395.0,370.8,1.98,,,66.0,11.24,45.0,10.47,37.8,0.003372,-0.11115,44.1,1.6253795801944284,11.258095888527032,1.0310159013493011e-11,0.1974273031299818,122.62912024957947,9.482481250079347,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A400,SunPower,Mono-c-Si,0,400.0,374.9,1.87,,,66.0,10.9,47.6,10.1,39.6,0.004142,-0.11281200000000001,46.4,1.6837042396000779,10.926033353513697,5.535404720807671e-12,0.2653250545615445,111.08991763217044,8.668560503828202,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A400-COM,SunPower,Mono-c-Si,0,400.0,370.6,2.03,,,72.0,10.9,52.1,10.1,43.3,0.0035970000000000004,-0.125561,48.0,1.8739481948490542,10.925270410424657,8.852683394470062e-12,0.2882040091379346,124.31233412967393,11.095222165877287,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M400,SunPower,Mono-c-Si,0,400.0,376.9,1.87,,,66.0,10.86,48.1,10.12,39.53,0.0045612000000000005,-0.11255400000000002,47.16,1.622648842451533,10.88785689430789,1.4074163704464442e-12,0.33875362919955254,132.06297780592973,-1.746099101680339,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M400-BLK,SunPower,Mono-c-Si,0,400.0,376.0,1.87,,,66.0,11.25,48.05,10.24,39.07,0.0049499999999999995,-0.11339799999999998,46.93,1.6629055392327179,11.30877022280693,3.0009441005265924e-12,0.36655200983830777,70.16665776791582,3.490854749264036,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-400,SunPower,Mono-c-Si,0,400.0,379.4,1.9,,,112.0,6.53,81.09,5.88,67.98,0.0036568,-0.18893970000000002,45.0,2.8389440141607594,6.556608990413552,2.388717661874165e-12,0.6774838042634004,166.25843996525467,7.482000777446653,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-400-BLK,SunPower,Mono-c-Si,0,400.0,379.4,1.9,,,112.0,6.3,81.26,5.75,69.55,0.003528,-0.18933580000000003,45.0,2.8548804174492313,6.312318277219606,2.583164366566451e-12,0.425552627516724,217.64257342445,8.45004849016789,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-400-BLK-R,SunPower,Mono-c-Si,0,400.0,377.7,1.9,,,112.0,12.6,40.63,11.54,34.67,0.00567,-0.09507420000000001,46.01,1.419027035912012,12.62552932770951,4.3826398714823465e-12,0.11809216725210403,58.28439059397363,6.676607006381648,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-400-COM,SunPower,Mono-c-Si,0,400.0,372.4,1.77,,,104.0,6.57,75.4,6.07,66.0,0.0024966000000000003,-0.17191200000000004,47.0,2.8296283671251463,6.571157465062061,1.6823406807575723e-11,0.04661799428312914,264.6129312995543,28.89502959115861,-0.34,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-400-COM-R,SunPower,Mono-c-Si,0,400.0,377.7,1.9,,,112.0,13.06,40.55,11.81,33.88,0.005876999999999999,-0.094887,46.01,1.410479520988377,13.113333811582605,3.988773579519931e-12,0.18158814358304143,44.46599794003494,5.585681527155997,-0.28,N,2025.7.3,6/23/2025,2.0,first_pass +SunPower SPR-MAX3-400-R,SunPower,Mono-c-Si,0,400.0,377.7,1.9,,,112.0,13.06,40.55,11.81,33.88,0.005876999999999999,-0.094887,46.01,1.410479520988377,13.113333811582605,3.988773579519931e-12,0.18158814358304143,44.46599794003494,5.585681527155997,-0.28,N,2025.7.3,6/23/2025,2.0,first_pass +SunPower SPR-U400-BLK,SunPower,Mono-c-Si,1,400.0,375.6,1.98,,,66.0,11.32,45.2,10.54,38.0,0.003396,-0.11164400000000001,44.1,1.6336300442974723,11.338205866119138,1.055961954937742e-11,0.19337599155490953,120.2368629720674,9.634241016813354,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A405,SunPower,Mono-c-Si,0,405.0,379.7,1.87,,,66.0,10.9,47.7,10.1,39.8,0.004142,-0.113049,46.4,1.685534936110557,10.924996365522569,5.377204736834202e-12,0.25358575513125414,110.57946527887782,8.413035958340666,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A405-BLK,SunPower,Mono-c-Si,0,405.0,380.8,1.87,,,66.0,10.89,48.15,10.25,40.02,0.0039204,-0.11459699999999999,46.3,1.6620656000194807,10.904487898810089,2.798303767979488e-12,0.27996101401571055,210.43599804572617,2.2810200435660914,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A405-COM,SunPower,Mono-c-Si,0,405.0,375.4,2.03,,,72.0,10.9,52.7,10.1,43.4,0.0035970000000000004,-0.127007,48.0,1.8869399872730181,10.928799174612196,7.807201122139878e-12,0.3368236236579445,127.48203871662841,9.959699205159257,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M405,SunPower,Mono-c-Si,0,405.0,381.8,1.87,,,66.0,10.88,48.1,10.24,39.54,0.004569600000000001,-0.11255400000000002,47.16,1.6157515355834147,10.897638982262963,1.2569082037827576e-12,0.33666957653889446,207.66305790094822,-2.727837830746571,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M405-BLK,SunPower,Mono-c-Si,0,405.0,380.8,1.87,,,66.0,11.26,48.07,10.3,39.31,0.0049544,-0.1134452,46.93,1.6644083777550076,11.309533979425265,3.0623532217278165e-12,0.34125288420308525,77.57316336912038,3.638359906545442,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-405-BLK-R,SunPower,Mono-c-Si,0,405.0,382.5,1.9,,,112.0,12.62,40.65,11.61,34.89,0.005679,-0.095121,46.01,1.420625104651566,12.639464075759237,4.4912975319615955e-12,0.09874420135704602,64.02316950223872,6.860162333531996,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-405-R,SunPower,Mono-c-Si,0,405.0,382.5,1.9,,,112.0,13.07,40.57,11.88,34.08,0.0058815000000000004,-0.09493380000000001,46.01,1.4113575691226714,13.114179593199792,4.029233859552372e-12,0.16429062906319833,48.60340186553839,5.647162446337633,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-U405-BLK,SunPower,Mono-c-Si,1,405.0,380.4,1.98,,,66.0,11.4,45.4,10.61,38.2,0.00342,-0.112138,44.1,1.641879851281935,11.418302061102487,1.0812673414347341e-11,0.18937819105443374,117.96001387002904,9.78521705064058,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A410,SunPower,Mono-c-Si,0,410.0,384.5,1.87,,,66.0,10.9,47.9,10.1,40.2,0.004142,-0.11352299999999999,46.4,1.7015920083236127,10.9224135638503,6.2417006570509735e-12,0.22732962908740836,110.55327817884965,9.745491981378587,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A410-BLK,SunPower,Mono-c-Si,0,410.0,385.6,1.87,,,66.0,10.9,48.18,10.31,40.26,0.0039239999999999995,-0.11466839999999999,46.3,1.6636144233083503,10.909740805562146,2.8409023951052766e-12,0.25630550512218603,286.8068756283494,2.3800887771451227,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A410-COM,SunPower,Mono-c-Si,0,410.0,380.1,2.03,,,72.0,10.9,53.4,10.1,44.4,0.0035970000000000004,-0.128694,48.0,1.9211280949038132,10.925095982290014,8.906426116526896e-12,0.29317205968200866,127.33414548537012,11.150160375233892,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M410,SunPower,Mono-c-Si,0,410.0,386.6,1.87,,,66.0,10.89,48.15,10.24,40.03,0.004573800000000001,-0.11267100000000001,47.16,1.6265973341270625,10.906429296584905,1.4847039377886319e-12,0.2869285122588068,190.18778339025565,-1.3650208425790333,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M410-BLK,SunPower,Mono-c-Si,0,410.0,385.7,1.87,,,66.0,11.28,48.1,10.37,39.55,0.004963199999999999,-0.113516,46.93,1.6660043864485985,11.321234524764495,3.1142519795326863e-12,0.3169715998071262,86.70985459250105,3.748165701985582,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-410-BLK,SunPower,Mono-c-Si,0,410.0,389.1,1.9,,,112.0,6.31,81.4,5.82,70.4,0.0035336000000000005,-0.18966200000000003,45.0,2.8593914199436274,6.316723965486592,2.606700760650011e-12,0.28981979483788617,271.9768373409439,8.474455270534197,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-410-BLK-R,SunPower,Mono-c-Si,0,410.0,387.4,1.9,,,112.0,12.63,40.68,11.68,35.1,0.005683500000000001,-0.0951912,46.01,1.4216410358803013,12.644238042508924,4.517632565847764e-12,0.08168610220229156,72.46048557785568,6.882699537441167,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-410-COM,SunPower,Mono-c-Si,0,410.0,389.1,1.9,,,112.0,6.54,81.18,5.96,68.79,0.0036624,-0.18914940000000002,45.0,2.840292984324733,6.557340106068155,2.380777200738312e-12,0.5407597137463639,203.95310819910068,7.393154676316464,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-410-COM-R,SunPower,Mono-c-Si,0,410.0,387.4,1.9,,,112.0,13.09,40.59,11.96,34.29,0.005890499999999999,-0.09498060000000001,46.01,1.4123771385538344,13.125728986209811,4.085018391620778e-12,0.14615475103892997,53.54659884881797,5.733427330408438,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-410-R,SunPower,Mono-c-Si,0,410.0,387.4,1.9,,,112.0,13.09,40.59,11.96,34.29,0.005890499999999999,-0.09498060000000001,46.01,1.4123771385538344,13.125728986209811,4.085018391620778e-12,0.14615475103892997,53.54659884881797,5.733427330408438,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-U410-BLK,SunPower,Mono-c-Si,1,410.0,385.2,1.98,,,66.0,11.48,45.7,10.68,38.4,0.0034440000000000004,-0.11287900000000001,44.1,1.6519442360466958,11.49921020898387,1.0742460969281967e-11,0.19486642995986653,116.45196683759387,9.666209920510571,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A415,SunPower,Mono-c-Si,0,415.0,389.4,1.87,,,66.0,10.9,48.0,10.2,40.4,0.004142,-0.11375999999999999,46.4,1.6995353476386859,10.915029694422241,5.752670142856012e-12,0.2159277924696282,156.59752426136154,8.970189718604725,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A415-BLK,SunPower,Mono-c-Si,0,415.0,390.5,1.87,,,66.0,10.91,48.21,10.37,40.5,0.0039276,-0.1147398,46.3,1.6651474854340158,10.915685523594583,2.883203705266482e-12,0.23294840179571905,447.0066498326042,2.47628307236693,-0.299,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A415-COM,SunPower,Mono-c-Si,0,415.0,384.9,2.03,,,72.0,10.9,54.0,10.1,44.9,0.0035970000000000004,-0.13014,48.0,1.9427379581014543,10.925086073013379,8.909485540450672e-12,0.296338537050807,128.76029090015692,11.15328719398625,-0.329,N,2025.7.3,6/23/2025,4.0,bootstrapping +SunPower SPR-M415,SunPower,Mono-c-Si,0,415.0,391.4,1.87,,,66.0,11.52,48.07,10.55,39.33,0.0048384000000000005,-0.11248380000000001,47.16,1.6309996189865827,11.570997567580672,1.7348632638836777e-12,0.3384446407633586,76.45231817657904,-0.43565676044962853,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M415-BLK,SunPower,Mono-c-Si,0,415.0,390.5,1.87,,,66.0,11.29,48.13,10.43,39.79,0.0049676,-0.1135868,46.93,1.6676451924347682,11.32379179038306,3.1661894876181656e-12,0.2932979322540112,97.99225252753826,3.863498318580734,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-415,SunPower,Mono-c-Si,0,415.0,393.9,1.9,,,112.0,6.55,81.23,6.0,69.2,0.0036680000000000003,-0.18926590000000001,45.0,2.8422295270444633,6.563733306903824,2.4024236123894638e-12,0.4729480329908077,225.56909554658998,7.439774154832509,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-415-BLK,SunPower,Mono-c-Si,0,415.0,393.9,1.9,,,112.0,6.32,81.4,5.86,70.8,0.0035392000000000006,-0.18966200000000003,45.0,2.859773604508928,6.3244067941447835,2.6358626961720836e-12,0.21600713420159737,309.78644424819225,8.537995098956404,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-415-BLK-R,SunPower,Mono-c-Si,0,415.0,392.2,1.9,,,112.0,12.64,40.7,11.75,35.31,0.005688,-0.09523800000000002,46.01,1.4224679205709647,12.649715732772222,4.55852318012892e-12,0.06399369530265368,83.25468885381154,6.932953118936996,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-415-COM,SunPower,Mono-c-Si,0,415.0,393.9,1.9,,,112.0,6.55,81.23,6.0,69.2,0.0036680000000000003,-0.18926590000000001,45.0,2.8422295270444633,6.563733306903824,2.4024236123894638e-12,0.4729480329908077,225.56909554658998,7.439774154832509,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-415-COM-R,SunPower,Mono-c-Si,0,415.0,392.2,1.9,,,112.0,13.1,40.61,12.03,34.49,0.005895,-0.09502740000000001,46.01,1.413236735437878,13.128480662594928,4.124492571814644e-12,0.12931252744698615,59.47874648936356,5.790293701442603,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-415-R,SunPower,Mono-c-Si,0,415.0,392.2,1.9,,,112.0,13.1,40.61,12.03,34.49,0.005895,-0.09502740000000001,46.01,1.413236735437878,13.128480662594928,4.124492571814644e-12,0.12931252744698615,59.47874648936356,5.790293701442603,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-U415-BLK,SunPower,Mono-c-Si,1,415.0,390.0,1.98,,,66.0,11.57,45.9,10.75,38.7,0.003471,-0.113373,44.1,1.6630462652257103,11.588839298224551,1.1526172990739969e-11,0.17998469029396208,110.53611684779504,10.232814700567221,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A420,SunPower,Mono-c-Si,0,420.0,394.2,1.87,,,66.0,11.0,48.2,10.2,40.8,0.00418,-0.114234,46.4,1.7188505428591743,11.018523162133043,7.018741444272694e-12,0.18777634821364036,111.51116936344407,10.720591367324941,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A420-COM,SunPower,Mono-c-Si,0,420.0,389.7,2.03,,,72.0,10.9,54.7,10.1,45.4,0.0035970000000000004,-0.131827,48.0,1.9661566272032627,10.925797770111181,8.691415941888254e-12,0.3094968089635501,130.7677062142352,10.928464879153774,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M420,SunPower,Mono-c-Si,0,420.0,396.3,1.87,,,66.0,11.53,48.1,10.62,39.56,0.0048426,-0.11255400000000002,47.16,1.6317975536377547,11.571762127567725,1.7403573565420533e-12,0.3160887452682401,87.26814093287496,-0.43882238841805743,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M420-BLK,SunPower,Mono-c-Si,0,420.0,395.3,1.87,,,66.0,11.3,48.15,10.49,40.02,0.004972,-0.11363399999999999,46.93,1.6688863351815642,11.327146994475191,3.215870421736701e-12,0.2700493015168403,112.40862888599631,3.9703279732602637,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-420,SunPower,Mono-c-Si,0,420.0,398.8,1.9,,,112.0,6.56,81.27,6.03,69.61,0.0036735999999999995,-0.1893591,45.0,2.8462775142720864,6.570916289448887,2.479919397789212e-12,0.40342081322337975,242.43041081486467,7.695078944106511,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-420-BLK,SunPower,Mono-c-Si,0,420.0,398.8,1.9,,,112.0,6.32,81.5,5.89,71.3,0.0035392000000000006,-0.18989500000000004,45.0,2.8640576587219058,6.3224867945736865,2.6708738934830496e-12,0.14114644243351016,358.71298979371034,8.634740329347677,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-420-BLK-R,SunPower,Mono-c-Si,0,420.0,397.0,1.9,,,112.0,12.65,40.73,11.82,35.52,0.0056925,-0.09530820000000001,46.01,1.4234706733744384,12.656136081194463,4.583631745444188e-12,0.047372615171061214,97.66226410573614,6.951927402416734,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-420-COM,SunPower,Mono-c-Si,0,420.0,398.8,1.9,,,112.0,6.56,81.27,6.03,69.61,0.0036735999999999995,-0.1893591,45.0,2.8462775142720864,6.570916289448887,2.479919397789212e-12,0.40342081322337975,242.43041081486467,7.695078944106511,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A425,SunPower,Mono-c-Si,0,425.0,399.0,1.87,,,66.0,11.0,48.4,10.2,41.2,0.00418,-0.11470799999999999,46.4,1.7307339798041184,11.016088692092316,7.576714423050366e-12,0.16275294716344815,111.27582093396074,11.416756976457085,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A425-COM,SunPower,Mono-c-Si,0,425.0,394.4,2.03,,,72.0,10.9,55.3,10.1,46.0,0.0035970000000000004,-0.13327299999999997,48.0,1.989917788828798,10.924921680891625,8.960332537084876e-12,0.30130672406275627,131.7825756432457,11.204965599726226,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M425,SunPower,Mono-c-Si,0,425.0,401.1,1.87,,,66.0,11.55,48.13,10.68,39.8,0.004851,-0.11262420000000002,47.16,1.6341347469026903,11.585145336844553,1.7926591122913017e-12,0.2927051049923867,96.19324411193631,-0.22212705950435035,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M425-BLK,SunPower,Mono-c-Si,0,425.0,400.1,1.87,,,66.0,11.32,48.18,10.58,40.26,0.0049808000000000005,-0.1137048,46.93,1.6689822994871308,11.339716646007352,3.1931461421797713e-12,0.24687730120491289,141.7406921319079,3.8661976968762435,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-425,SunPower,Mono-c-Si,0,425.0,403.6,1.9,,,112.0,6.57,81.32,6.07,70.01,0.0036792000000000005,-0.1894756,45.0,2.8479779534035217,6.578171932251414,2.4962966479598885e-12,0.3392911241266836,272.7803679397667,7.719415685318569,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-425-COM,SunPower,Mono-c-Si,0,425.0,403.6,1.9,,,112.0,6.57,81.32,6.07,70.01,0.0036792000000000005,-0.1894756,45.0,2.8479779534035217,6.578171932251414,2.4962966479598885e-12,0.3392911241266836,272.7803679397667,7.719415685318569,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-425-COM-R,SunPower,Mono-c-Si,0,425.0,401.9,1.9,,,112.0,13.13,40.66,12.18,34.9,0.0059085,-0.09514439999999999,46.01,1.4152643334711328,13.14658265369266,4.204118371410323e-12,0.09608285898816596,76.07756649212757,5.895478275597722,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-425-R,SunPower,Mono-c-Si,0,425.0,401.9,1.9,,,112.0,13.13,40.66,12.18,34.9,0.0059085,-0.09514439999999999,46.01,1.4152643334711328,13.14658265369266,4.204118371410323e-12,0.09608285898816596,76.07756649212757,5.895478275597722,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A430-COM,SunPower,Mono-c-Si,0,430.0,399.2,2.03,,,72.0,10.9,51.2,10.1,42.7,0.0035970000000000004,-0.123392,48.0,1.8447580825503638,10.923887248242124,9.284444845979997e-12,0.2664239471652287,121.57202030905663,11.528180735925341,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M430,SunPower,Mono-c-Si,0,430.0,405.9,1.87,,,66.0,11.56,48.15,10.74,40.03,0.0048552000000000005,-0.11267100000000001,47.16,1.6354297513415104,11.588367364060522,1.8234392407303076e-12,0.2699939375052386,110.0253767693613,-0.106442024087259,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-430,SunPower,Mono-c-Si,0,430.0,408.5,1.9,,,112.0,6.57,81.36,6.11,70.42,0.0036792000000000005,-0.1895688,45.0,2.84759201639479,6.575523807840351,2.469879744709059e-12,0.27406269785029075,325.96932724864484,7.597278551131398,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-430-COM,SunPower,Mono-c-Si,0,430.0,408.5,1.9,,,112.0,6.57,81.36,6.11,70.42,0.0036792000000000005,-0.1895688,45.0,2.84759201639479,6.575523807840351,2.469879744709059e-12,0.27406269785029075,325.96932724864484,7.597278551131398,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-430-COM-R,SunPower,Mono-c-Si,0,430.0,406.7,1.9,,,112.0,13.15,40.68,12.25,35.11,0.0059175,-0.0951912,46.01,1.4168092835219797,13.162066398969642,4.302883339755102e-12,0.07876325853450783,85.83644985977571,6.067634722954222,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-430-R,SunPower,Mono-c-Si,0,430.0,406.7,1.9,,,112.0,13.15,40.68,12.25,35.11,0.0059175,-0.0951912,46.01,1.4168092835219797,13.162066398969642,4.302883339755102e-12,0.07876325853450783,85.83644985977571,6.067634722954222,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A435-COM,SunPower,Mono-c-Si,0,435.0,404.0,2.03,,,72.0,10.9,51.4,10.1,43.0,0.0035970000000000004,-0.123874,48.0,1.8548244149218402,10.922631910721131,9.687642034765787e-12,0.25234808020408545,121.5360961841438,11.915948423177955,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M435,SunPower,Mono-c-Si,0,435.0,410.8,1.87,,,66.0,11.57,48.18,10.82,40.26,0.004859400000000001,-0.11274120000000001,47.16,1.6355131174610047,11.590874831241072,1.8075286649073388e-12,0.24858380879023032,137.77905958140124,-0.21346909352344168,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M435-BLK,SunPower,Mono-c-Si,0,435.0,409.8,1.87,,,66.0,11.34,48.23,10.68,40.73,0.004989599999999999,-0.1138228,46.93,1.6493483829677562,11.340005811915697,2.2648219792814072e-12,0.2063750470919468,402671.8366410357,0.8301696322029164,-0.29,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-435,SunPower,Mono-c-Si,0,435.0,413.3,1.9,,,112.0,6.58,81.4,6.14,70.8,0.0036848,-0.18966200000000003,45.0,2.8509640464561516,6.583876178399815,2.532034298283166e-12,0.21249217203662343,360.715722642127,7.790921076200663,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-435-COM,SunPower,Mono-c-Si,0,435.0,413.3,1.9,,,112.0,6.58,81.4,6.14,70.8,0.0036848,-0.18966200000000003,45.0,2.8509640464561516,6.583876178399815,2.532034298283166e-12,0.21249217203662343,360.715722642127,7.790921076200663,-0.272,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-435-COM-R,SunPower,Mono-c-Si,0,435.0,411.6,1.9,,,112.0,13.16,40.7,12.32,35.31,0.005921999999999999,-0.09523800000000002,46.01,1.417632187527787,13.168159342386998,4.340408451127335e-12,0.06276070165212323,101.22517168916683,6.115625460433995,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-MAX3-435-R,SunPower,Mono-c-Si,0,435.0,411.6,1.9,,,112.0,13.16,40.7,12.32,35.31,0.005921999999999999,-0.09523800000000002,46.01,1.417632187527787,13.168159342386998,4.340408451127335e-12,0.06276070165212323,101.22517168916683,6.115625460433995,-0.28,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A440-COM,SunPower,Mono-c-Si,0,440.0,408.8,2.03,,,72.0,10.9,51.6,10.2,43.4,0.0035970000000000004,-0.124356,48.0,1.8581145532853214,10.914350225492903,9.238550634290401e-12,0.22840398483744026,173.48880270046183,11.43965271085612,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M440,SunPower,Mono-c-Si,0,440.0,415.6,1.87,,,66.0,11.58,48.21,10.87,40.49,0.0048636,-0.11281140000000002,47.16,1.622423074721574,11.580006252604523,1.4412017209150218e-12,0.2301055400560019,426162.36221320124,-2.1976588532574453,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M445,SunPower,Mono-c-Si,0,445.0,420.5,1.87,,,66.0,11.6,48.23,10.93,40.72,0.004872,-0.1128582,47.16,1.639538461747629,11.612483336022333,1.904577565053752e-12,0.20516209461134274,190.64457565112588,0.16978331203929534,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X20-445-COM,SunPower,Mono-c-Si,0,445.0,412.7,2.1620820000000003,2.067,1.046,128.0,6.21,90.5,5.8,76.7,0.00082593,-0.263355,44.5,3.471626493639118,6.21594917162505,2.8846392135479545e-11,0.5108634600906241,533.2611513080888,6.0543054666780245,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A450-COM,SunPower,Mono-c-Si,0,450.0,418.3,2.03,,,72.0,11.0,51.9,10.2,44.0,0.00363,-0.125079,48.0,1.8846468962061422,11.016851961024358,1.1621242197475841e-11,0.1872871713292209,122.25039474406556,13.50179070030492,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M450-COM,SunPower,Mono-c-Si,0,450.0,422.9,2.12,,,72.0,11.51,52.43,10.52,42.76,0.0042587,-0.12373479999999999,46.51,1.8124564951013062,11.56331092698593,2.9860384889276528e-12,0.3769821623073301,81.39165713111308,3.3439677639063308,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X20-450-COM,SunPower,Mono-c-Si,0,450.0,418.9,2.16,,,128.0,6.26,90.5,5.87,76.7,0.00193434,-0.2654365,45.67,3.3784327140949086,6.265585797295901,1.4217617792113474e-11,0.5425435672811123,608.0282842792194,-0.8977043375037153,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M455-COM,SunPower,Mono-c-Si,0,455.0,427.7,2.12,,,72.0,11.52,52.45,10.58,42.99,0.0042623999999999995,-0.12378200000000002,46.51,1.813480082822615,11.564982612256959,3.0201789281239905e-12,0.3534951939575564,90.52974988295603,3.4147942038856822,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-A460-COM,SunPower,Mono-c-Si,0,460.0,427.9,2.03,,,72.0,10.9,52.56,10.47,43.92,0.0035970000000000004,-0.12666960000000002,48.0,1.870726418496443,10.900004715387047,6.846508262892296e-12,0.2658146410181721,614455.4303687003,8.642831191387993,-0.329,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M460-COM,SunPower,Mono-c-Si,0,460.0,432.6,2.12,,,72.0,11.54,52.48,10.64,43.23,0.004269799999999999,-0.12385279999999997,46.51,1.8156078635436965,11.578296096286271,3.0912099584466862e-12,0.32987318174208197,99.40273000795703,3.58335178560166,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X21-460-COM,SunPower,Mono-c-Si,0,460.0,428.4,2.16,,,128.0,6.4,90.5,6.0,76.7,0.0019776,-0.2654365,45.67,3.378801274526013,6.405770254355298,1.4574465858197062e-11,0.5305371241279563,588.4381173155689,-0.8754506952210964,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X22-460-COM,SunPower,Mono-c-Si,0,460.0,428.4,2.1620820000000003,2.067,1.046,128.0,6.4,90.5,6.0,76.7,0.0019776,-0.2654365,45.7,3.378801274526013,6.405770254355298,1.4574465858197062e-11,0.5305371241279563,588.4381173155689,-0.8754506952210964,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M465-COM,SunPower,Mono-c-Si,0,465.0,437.4,2.12,,,72.0,11.55,52.51,10.7,43.46,0.0042735,-0.1239236,46.51,1.8167852488341514,11.581454437380977,3.1167699141859995e-12,0.3079008303463315,113.0605055404812,3.627060362497221,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M470-COM,SunPower,Mono-c-Si,0,470.0,442.2,2.12,,,72.0,11.56,52.53,10.76,43.69,0.0042772,-0.12397079999999999,46.51,1.8177748053930773,11.585219498981413,3.1502735168256126e-12,0.2852566478143015,130.7546533843457,3.6916695012055714,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X21-470-COM,SunPower,Mono-c-Si,0,470.0,438.0,2.16,,,128.0,6.43,91.8,6.03,77.9,0.00198687,-0.2692494,45.67,3.4290412546855054,6.435529804875758,1.4842819378487762e-11,0.5171431176004834,601.3286789458972,-0.7676902444844809,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X22-470-COM,SunPower,Mono-c-Si,0,470.0,438.0,2.1620820000000003,2.067,1.046,128.0,6.43,91.8,6.03,77.9,0.00198687,-0.2692494,45.7,3.4290412546855054,6.435529804875758,1.4842819378487762e-11,0.5171431176004834,601.3286789458972,-0.7676902444844809,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M475-COM,SunPower,Mono-c-Si,0,475.0,447.0,2.12,,,72.0,11.57,52.56,10.82,43.92,0.0042809,-0.12404160000000002,46.51,1.783448661788486,11.570007203795223,1.8375543525959756e-12,0.2707715184163072,434886.08450431906,-0.9672110097124201,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X22-475-COM,SunPower,Mono-c-Si,0,475.0,442.8,2.1620820000000003,2.067,1.046,128.0,6.45,92.5,6.07,78.5,0.00199305,-0.2713025,45.7,3.449142524770276,6.454581248925482,1.4265002347421032e-11,0.5206880965876528,733.0835531616148,-1.124559381692977,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-M480-COM,SunPower,Mono-c-Si,0,480.0,451.9,2.12,,,72.0,11.58,52.59,10.87,44.15,0.0042845999999999995,-0.1241124,46.51,1.790231971211237,11.580006598557892,2.0222472799985517e-12,0.2485405139698433,436171.4664973712,-0.18383965901735588,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X22-480-COM,SunPower,Mono-c-Si,0,480.0,452.9,2.16,,,128.0,6.48,92.7,6.08,79.0,0.0026568000000000004,-0.218772,46.23,3.212299105851026,6.486711360617353,1.8510573564765036e-12,0.551907972493321,532.8820588956374,4.0106284079586185,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +SunPower SPR-X22-485-COM,SunPower,Mono-c-Si,0,485.0,457.7,2.16,,,128.0,6.55,92.7,6.16,78.8,0.0026855000000000004,-0.218772,46.23,3.2050782766638855,6.556469202310742,1.758427561446191e-12,0.5839804013756629,591.274065006741,3.4673558088613956,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P660220,Sunrise Solartech,Multi-c-Si,0,220.0,195.1,1.623904,1.637,0.992,60.0,8.37,35.07,7.75,28.4,0.0054572399999999995,-0.12579609,46.3,1.5564768876079367,8.384011896642392,1.339734549595747e-09,0.27849143364802387,166.35678182694062,13.634940116056725,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P660225,Sunrise Solartech,Multi-c-Si,0,225.0,199.6,1.623904,1.637,0.992,60.0,8.46,35.46,7.87,28.6,0.00551592,-0.12719502000000002,46.3,1.5658241577780714,8.471292380914846,1.2149711858414627e-09,0.2967565479570353,222.32349191785627,12.617443407905787,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P660230,Sunrise Solartech,Multi-c-Si,0,230.0,204.2,1.623904,1.637,0.992,60.0,8.56,35.84,7.96,28.9,0.00558112,-0.12855808000000002,46.3,1.582724252938258,8.571740728960842,1.2309207154303607e-09,0.29736568430882565,216.80521985455002,12.630500720964873,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P660235,Sunrise Solartech,Multi-c-Si,0,235.0,208.7,1.623904,1.637,0.992,60.0,8.65,36.21,8.05,29.2,0.0056398,-0.12988527000000002,46.3,1.5984207113617497,8.661249182528119,1.233737089624954e-09,0.29714604306077386,228.48899394444385,12.552877194879649,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P660240,Sunrise Solartech,Multi-c-Si,0,240.0,213.3,1.623904,1.637,0.992,60.0,8.78,36.46,8.17,29.4,0.005724559999999999,-0.13078202000000003,46.3,1.6095111637008364,8.791518549967464,1.2530700662787216e-09,0.294989314499023,224.85533355063367,12.55905264297402,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P672275,Sunrise Solartech,Multi-c-Si,0,275.0,244.1,1.9423359999999998,1.958,0.992,72.0,8.62,42.61,7.98,34.5,0.0056202399999999994,-0.15284207,46.3,1.891117363046392,8.63459287353005,1.3794733816833865e-09,0.32941555261222494,194.58559646132917,13.633640066730866,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P672280,Sunrise Solartech,Multi-c-Si,0,280.0,248.7,1.9423359999999998,1.958,0.992,72.0,8.68,43.08,8.05,34.8,0.0056593599999999996,-0.15452796000000002,46.3,1.907358869138729,8.693735438521541,1.3185521026651962e-09,0.3429711511754473,216.73794126102283,13.144909207915706,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P672285,Sunrise Solartech,Multi-c-Si,0,285.0,253.3,1.9423359999999998,1.958,0.992,72.0,8.76,43.4,8.15,35.0,0.0057115199999999994,-0.1556758,46.3,1.916183184237422,8.771615473476164,1.2545120115562527e-09,0.3513580438902002,264.982550647373,12.591144396680567,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P672290,Sunrise Solartech,Multi-c-Si,0,290.0,257.8,1.9423359999999998,1.958,0.992,72.0,8.89,43.52,8.27,35.1,0.00579628,-0.15610624,46.3,1.9217106866401465,8.901869645269956,1.2763841010616422e-09,0.34669805250449925,259.66631134724395,12.614994892648427,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-P672295,Sunrise Solartech,Multi-c-Si,0,295.0,262.4,1.9423359999999998,1.958,0.992,72.0,8.95,43.77,8.36,35.3,0.005835399999999999,-0.15700299,46.3,1.9283137864132673,8.958656008841809,1.2257949663452257e-09,0.3470641012399396,358.8519290496224,12.169140726416927,-0.4946,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-M672305,Sunrise Solartech,Mono-c-Si,0,305.0,267.1,1.9423359999999998,1.958,0.992,72.0,9.1,44.53,8.43,36.2,0.0049594999999999995,-0.1616439,46.7,2.070677527153399,9.111701247349286,4.077216826455895e-09,0.2840436148109937,220.8994524403832,22.25325413039479,-0.5513,N,2025.7.3,6/23/2025,4.0,first_pass +Sunrise Solartech SR-M672310,Sunrise Solartech,Mono-c-Si,0,310.0,271.6,1.9423359999999998,1.958,0.992,72.0,9.2,44.77,8.52,36.4,0.005014,-0.16251510000000002,46.7,2.082386656435158,9.21201282932875,4.143832500937808e-09,0.2817106550834667,215.74769490719984,22.307541050436633,-0.5513,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SMX-245P,SunSpark Technology Inc,Multi-c-Si,0,245.0,219.7,1.64505,1.65,0.997,60.0,8.76,37.5,8.14,30.1,0.00449388,-0.13485,45.7,1.6008608635901653,8.774992506233136,5.759899166255484e-10,0.3370279917946102,196.9227705873778,5.5960000570802535,-0.473,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SMX-250P,SunSpark Technology Inc,Multi-c-Si,0,250.0,224.3,1.64505,1.65,0.997,60.0,8.85,37.7,8.2,30.5,0.0045400499999999995,-0.1355692,45.7,1.6195936536515467,8.86634418340103,6.713960987933396e-10,0.30048593743503627,162.70626499831536,6.838160994251172,-0.473,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SMX-255P,SunSpark Technology Inc,Multi-c-Si,0,255.0,229.0,1.64505,1.65,0.997,60.0,8.92,38.0,8.28,30.8,0.00457596,-0.136648,45.7,1.6326372253189414,8.934731314386735,6.795511615949247e-10,0.2924699699396509,177.0943366410266,6.868931463704129,-0.473,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SMX-260P,SunSpark Technology Inc,Multi-c-Si,0,260.0,233.6,1.64505,1.65,0.997,60.0,8.98,38.1,8.37,31.1,0.00460674,-0.13700759999999998,45.7,1.6400935963117222,8.990809712581084,7.184398219514522e-10,0.26070471896661057,216.57642137471774,7.281659388045485,-0.473,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SMX-265P,SunSpark Technology Inc,Multi-c-Si,0,265.0,238.2,1.64505,1.65,0.997,60.0,9.03,38.6,8.44,31.4,0.004632389999999999,-0.1388056,45.7,1.6556735304201673,9.039258023952497,6.671151684168264e-10,0.2782304035862108,271.3776925928046,6.5810595395800116,-0.473,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-275M,SunSpark Technology Inc,Mono-c-Si,0,275.0,248.1,1.64505,1.65,0.997,60.0,9.26,38.88,8.68,31.7,0.0024168600000000003,-0.13258080000000003,45.92,1.5990153033582786,9.26916504712501,2.5159403070601837e-10,0.2800859237440438,282.9877367530589,4.010648617438616,-0.4566,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-280M,SunSpark Technology Inc,Mono-c-Si,0,280.0,252.8,1.64505,1.65,0.997,60.0,9.33,39.08,8.81,31.81,0.00243513,-0.13326280000000001,45.92,1.5995325088690182,9.333451149261808,2.2748355442646583e-10,0.2870916874165306,776.1374574809396,3.0816757491584346,-0.4566,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-285M,SunSpark Technology Inc,Mono-c-Si,0,285.0,257.5,1.64505,1.65,0.997,60.0,9.44,39.28,8.94,31.92,0.00246384,-0.13394480000000003,45.92,1.6037935092577522,9.440984418691777,2.1760141226478707e-10,0.29231855743344,2803.1663244157257,2.606374089639338,-0.4566,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-290M,SunSpark Technology Inc,Mono-c-Si,0,290.0,262.1,1.64505,1.65,0.997,60.0,9.56,39.46,9.07,32.03,0.00249516,-0.1345586,45.92,1.6092207590956658,9.567179854009655,2.1447012040244682e-10,0.29450938915559555,999999.9805753747,2.3728373039279713,-0.4566,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-295M,SunSpark Technology Inc,Mono-c-Si,0,295.0,266.8,1.64505,1.65,0.997,60.0,9.67,39.64,9.2,32.14,0.0025238700000000005,-0.13517240000000003,45.92,1.6184020770365188,9.670002739878282,2.229060319877975e-10,0.28323540391267277,999999.8543714592,2.601897903515497,-0.4566,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-300M,SunSpark Technology Inc,Mono-c-Si,0,300.0,280.8,1.645,1.65,0.997,20.0,9.78,39.82,9.33,32.25,0.0028948800000000003,-0.09114798,45.6,1.3593603670817487,9.781272568163578,1.853036886441727e-12,0.3591626840493999,2760.2538023630786,3.7420801931446475,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-300MB,SunSpark Technology Inc,Mono-c-Si,0,300.0,273.9,1.645,,,20.0,9.78,39.82,9.33,32.25,0.00839124,-0.11543818,47.4,1.5845759464482947,9.780002821617074,1.192956862917763e-10,0.288448628553525,999999.6424727994,14.027416720821694,-0.3895,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-305M,SunSpark Technology Inc,Mono-c-Si,0,305.0,285.6,1.645,,,20.0,9.89,39.98,9.44,32.35,0.0029274400000000003,-0.09151422,45.6,1.363946733518943,9.890606939401808,1.840288591776708e-12,0.36011539641314,5868.034809863534,3.583941931962695,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-305MB,SunSpark Technology Inc,Mono-c-Si,0,305.0,278.6,1.645,,,20.0,9.89,39.98,9.44,32.35,0.008485620000000001,-0.11590202,47.4,1.590680234722869,9.890002844644668,1.201378963073757e-10,0.28756774377629635,999999.4235552369,13.989031408912782,-0.3895,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-310M,SunSpark Technology Inc,Mono-c-Si,0,310.0,290.4,1.645,,,20.0,10.1,40.1,9.56,32.46,0.0029896,-0.0917889,45.6,1.3731245849810796,10.11023192436811,2.074359350437409e-12,0.3529790731931446,348.42797111830754,4.473849272137316,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-310M3-60,SunSpark Technology Inc,Mono-c-Si,0,310.0,283.6,1.65,,,60.0,10.04,40.3,9.52,32.61,0.00052208,-0.10691589999999998,46.8,1.4934411624796926,10.044010291092627,1.9077258786843435e-11,0.33179748085688465,830.6745732430549,8.30332918726962,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-310M3B-60,SunSpark Technology Inc,Mono-c-Si,0,310.0,283.4,1.65,,,60.0,10.04,40.3,9.52,32.61,0.0005521999999999999,-0.0990977,48.2,1.4554746547570512,10.045319029917508,9.424408571415071e-12,0.34041956383597477,642.5631238033982,10.402619308604601,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-310MB,SunSpark Technology Inc,Mono-c-Si,0,310.0,283.3,1.645,,,20.0,10.1,40.1,9.56,32.46,0.0086658,-0.1162499,47.4,1.593442695332974,10.102461753989184,1.1850658082743079e-10,0.303291186616294,1244.3295821779986,13.67801739452861,-0.3895,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-315M,SunSpark Technology Inc,Mono-c-Si,0,315.0,295.2,1.645,,,20.0,10.21,40.22,9.67,32.58,0.0030221600000000003,-0.09206357999999999,45.6,1.3773252688604458,10.21963011238594,2.10236844936149e-12,0.347464066273353,368.38698595636754,4.493497500530651,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-315M3-60,SunSpark Technology Inc,Mono-c-Si,0,315.0,288.3,1.65,,,60.0,10.11,40.53,9.58,32.9,0.0005257199999999999,-0.10752608999999999,46.8,1.504817755437909,10.114849102262351,2.0196037404652273e-11,0.3188788240127309,664.8374971926852,8.744440364814862,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-315M3B-60,SunSpark Technology Inc,Mono-c-Si,0,315.0,288.1,1.65,,,60.0,10.11,40.53,9.58,32.9,0.00055605,-0.09966327,48.2,1.466481217042114,10.116140014552647,9.975295727225875e-12,0.32755302847104706,539.3409309142569,10.853120422488022,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-315MB,SunSpark Technology Inc,Mono-c-Si,0,315.0,288.1,1.645,,,20.0,10.21,40.22,9.67,32.58,0.008760180000000001,-0.11659778,47.4,1.5983409396072343,10.21193006756891,1.2011926892995045e-10,0.29816549535165876,1577.2871652432088,13.700768775555972,-0.3895,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-320M,SunSpark Technology Inc,Mono-c-Si,0,320.0,300.0,1.645,,,20.0,10.32,40.34,9.78,32.72,0.0030547200000000004,-0.09233826,45.6,1.3819220627412854,10.329032121688812,2.1482232912941347e-12,0.3397363942667371,388.17895928605316,4.5850018530415495,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-320M3-60,SunSpark Technology Inc,Mono-c-Si,0,320.0,293.1,1.65,,,60.0,10.18,40.78,9.65,33.18,0.00052936,-0.10818934,46.8,1.5156019447050382,10.1845613283535,2.089014733286121e-11,0.30940745066189773,690.5374281929802,8.978822411452972,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-320M3B-60,SunSpark Technology Inc,Mono-c-Si,0,320.0,292.8,1.65,,,60.0,10.18,40.78,9.65,33.18,0.0005599,-0.10027802,48.2,1.4769477197137808,10.18581798007528,1.0317081447068005e-11,0.31810501173135913,556.6035590522451,11.092333972590579,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-320MB,SunSpark Technology Inc,Mono-c-Si,0,320.0,292.8,1.645,,,20.0,10.32,40.34,9.78,32.72,0.008854560000000001,-0.11694566,47.4,1.603772352540083,10.32145441182648,1.227504985814112e-10,0.2907648072991023,2063.159213807679,13.80010607634007,-0.3895,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-325M3-60,SunSpark Technology Inc,Mono-c-Si,0,325.0,297.8,1.65,,,60.0,10.25,41.04,9.72,33.45,0.000533,-0.10887911999999998,46.8,1.5263392621077077,10.254268739597443,2.144140789443943e-11,0.30230535136817815,725.8887280912743,9.145924093446256,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-325M3B-60,SunSpark Technology Inc,Mono-c-Si,0,325.0,297.6,1.65,,,60.0,10.25,41.04,9.72,33.45,0.00056375,-0.10091736,48.2,1.4873805050682383,10.255499091109776,1.058857768884657e-11,0.31101932148811595,579.7227278179477,11.262869279540544,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-330M3-60,SunSpark Technology Inc,Mono-c-Si,0,330.0,302.5,1.65,,,60.0,10.32,41.3,9.78,33.76,0.00053664,-0.10956889999999998,46.8,1.5387369455610138,10.324981833806019,2.2617525584294074e-11,0.2905850115415679,601.9545247491031,9.559686723918148,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-330M3B-60,SunSpark Technology Inc,Mono-c-Si,0,330.0,302.3,1.65,,,60.0,10.32,41.3,9.78,33.76,0.0005675999999999999,-0.1015567,48.2,1.4993847003495018,10.326197701388066,1.116760334784946e-11,0.2993537687975971,498.46398506222977,11.685431916455846,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-335M3-60,SunSpark Technology Inc,Mono-c-Si,0,335.0,307.2,1.65,,,60.0,10.39,41.59,9.85,34.07,0.00054028,-0.11033827,46.8,1.5509456693443266,10.394689722031348,2.333598521916783e-11,0.2821124095077643,625.0152987917179,9.77465712230607,-0.3955,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-335M3B-60,SunSpark Technology Inc,Mono-c-Si,0,335.0,307.0,1.65,,,60.0,10.39,41.59,9.85,34.07,0.00057145,-0.10226981000000002,48.2,1.5112411736551414,10.395873417609165,1.1521332051567095e-11,0.2909104115103268,514.616772462106,11.904824967610447,-0.3747,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-360M,SunSpark Technology Inc,Mono-c-Si,0,360.0,337.1,1.942,,,24.0,9.51,48.0,9.12,39.5,0.00281496,-0.109872,45.6,1.6506138212151,9.510003365925598,2.2328289655525425e-12,0.35393192418049646,999994.633423594,5.590307766995401,-0.3116,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST6L60M(H)-360,SunSpark Technology Inc,Mono-c-Si,0,360.0,334.0,1.82,,,60.0,11.15,40.7,10.5,34.3,0.0037352500000000003,-0.11973940000000001,45.5,1.5374701392539556,11.158176772725628,3.493686371787805e-11,0.1533910574312434,209.16691250174011,1.3364317194242623,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L60M-360,SunSpark Technology Inc,Mono-c-Si,0,360.0,334.0,1.82,,,60.0,11.15,40.7,10.5,34.3,0.0037352500000000003,-0.11973940000000001,45.5,1.5374701392539556,11.158176772725628,3.493686371787805e-11,0.1533910574312434,209.16691250174011,1.3364317194242623,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-365M,SunSpark Technology Inc,Mono-c-Si,0,365.0,341.9,1.942,,,24.0,9.57,48.2,9.2,39.7,0.0028327200000000004,-0.1103298,45.6,1.659654337307232,9.570003288896228,2.333705807038027e-12,0.3370827730580364,980843.6187425528,5.920804779641814,-0.3116,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST6L60M(H)-365,SunSpark Technology Inc,Mono-c-Si,0,365.0,338.7,1.82,,,60.0,11.2,40.9,10.56,34.6,0.0037519999999999997,-0.1203278,45.5,1.5471458992098648,11.20695201522684,3.642978631755149e-11,0.1393131800838252,224.43961592910676,1.6383636375568638,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L60M-365,SunSpark Technology Inc,Mono-c-Si,0,365.0,338.7,1.82,,,60.0,11.2,40.9,10.56,34.6,0.0037519999999999997,-0.1203278,45.5,1.5471458992098648,11.20695201522684,3.642978631755149e-11,0.1393131800838252,224.43961592910676,1.6383636375568638,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-370M,SunSpark Technology Inc,Mono-c-Si,0,370.0,346.7,1.942,,,24.0,9.61,48.5,9.28,39.9,0.00284456,-0.11101649999999999,45.6,1.672143407049469,9.61000309922601,2.433015058501582e-12,0.3192056314066751,989787.9837373984,6.248702146574813,-0.3116,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST6L60M(H)-370,SunSpark Technology Inc,Mono-c-Si,0,370.0,343.5,1.82,,,60.0,11.26,41.1,10.61,34.9,0.0037721000000000005,-0.12091620000000002,45.5,1.5582535810450702,11.266666066137162,3.8851855628555876e-11,0.12496890852610061,211.09150316581471,2.126923860495421,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L60M-370,SunSpark Technology Inc,Mono-c-Si,0,370.0,343.5,1.82,,,60.0,11.26,41.1,10.61,34.9,0.0037721000000000005,-0.12091620000000002,45.5,1.5582535810450702,11.266666066137162,3.8851855628555876e-11,0.12496890852610061,211.09150316581471,2.126923860495421,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-375M,SunSpark Technology Inc,Mono-c-Si,0,375.0,351.5,1.942,,,24.0,9.68,48.7,9.33,40.2,0.00286528,-0.11147430000000001,45.6,1.6800251004870312,9.680003079024567,2.492823701466162e-12,0.31321802568929563,984714.5480485695,6.397856868125645,-0.3116,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-375M3-72,SunSpark Technology Inc,Mono-c-Si,0,375.0,349.2,1.97,,,72.0,9.99,48.44,9.45,39.74,0.00132867,-0.11218704,46.2,1.678408304422058,9.999916571723533,2.8854058631173667e-12,0.36516629781474724,367.87021009190477,6.436968889175587,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L60M(H)-375,SunSpark Technology Inc,Mono-c-Si,0,375.0,348.3,1.82,,,60.0,11.31,41.3,10.66,35.2,0.0037888500000000003,-0.1215046,45.5,1.547520883931506,11.31000346892041,2.9045174732848924e-11,0.11522602674792679,375684.8316336818,-0.33635792019653576,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L60M-375,SunSpark Technology Inc,Mono-c-Si,0,375.0,348.3,1.82,,,60.0,11.31,41.3,10.66,35.2,0.0037888500000000003,-0.1215046,45.5,1.547520883931506,11.31000346892041,2.9045174732848924e-11,0.11522602674792679,375684.8316336818,-0.33635792019653576,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-380M3-72,SunSpark Technology Inc,Mono-c-Si,0,380.0,354.0,1.97,,,72.0,10.06,48.7,9.51,40.02,0.0013379800000000001,-0.1127892,46.2,1.6892181361339451,10.070481760067667,2.9936485521793085e-12,0.35659217636437596,342.2437909853039,6.701664558138126,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-385M3-72,SunSpark Technology Inc,Mono-c-Si,0,385.0,358.8,1.97,,,72.0,10.12,48.97,9.57,40.28,0.00134596,-0.11341452,46.2,1.6990773997330426,10.130157500082111,3.037788349222909e-12,0.3518912193858284,350.5920839278149,6.776309667608939,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-390M3-72,SunSpark Technology Inc,Mono-c-Si,0,390.0,363.6,1.97,,,72.0,10.17,49.27,9.62,40.6,0.00135261,-0.11410932,46.2,1.710714137180687,10.179817810114862,3.117090029668755e-12,0.343619503146458,355.94601174090656,6.958074306597183,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G54M(H)-395,SunSpark Technology Inc,Mono-c-Si,1,395.0,366.3,1.95,,,54.0,13.69,36.8,12.81,30.9,0.006160499999999999,-0.111872,43.8,1.4725492198353192,13.702204296194306,1.8784396833558907e-10,0.10861221918611189,121.83425395380112,10.290900322558151,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-395M3-72,SunSpark Technology Inc,Mono-c-Si,0,395.0,368.3,1.97,,,72.0,10.23,49.56,9.67,40.89,0.00136059,-0.11478096000000002,46.2,1.7223240516306988,10.240397730238598,3.2143050318873455e-12,0.33760290555126515,332.15688858900506,7.1798910561454505,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST7F54M(H)-395,SunSpark Technology Inc,Mono-c-Si,0,395.0,368.1,1.953,,,54.0,13.69,36.75,12.81,30.85,0.0069955899999999994,-0.10267949999999999,44.8,1.403458974736089,13.70500239840579,5.6759341803537717e-11,0.12064972102859052,110.09537610376569,8.961059874112506,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M108(HCBF)-395W,SunSpark Technology Inc,Mono-c-Si,1,395.0,371.7,1.93,,,54.0,13.69,36.8,13.04,30.3,0.0064343,-0.09384,43.6,1.3277550411236967,13.69257656736035,1.2542943742033919e-11,0.18346242702572843,974.7855744478336,5.673935427597066,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G54M(H)-400,SunSpark Technology Inc,Mono-c-Si,1,400.0,371.1,1.95,,,54.0,13.78,37.0,12.89,31.1,0.006201,-0.11248,43.8,1.4816506403952396,13.792208296816604,1.9252049024771315e-10,0.10555424549089813,119.14336308538994,10.452941401339066,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-400M3-72,SunSpark Technology Inc,Mono-c-Si,0,400.0,373.1,1.97,,,72.0,10.29,49.86,9.73,41.18,0.0013685699999999997,-0.11547576,46.2,1.7333264480831878,10.300072033321383,3.265224585990094e-12,0.3326880671004464,339.88769772599665,7.265232065655808,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST7F54M(H)-400,SunSpark Technology Inc,Mono-c-Si,0,400.0,372.9,1.953,,,54.0,13.78,37.0,12.89,31.05,0.00704158,-0.103378,44.8,1.4130059692811547,13.795439343978543,5.711178669860268e-11,0.12152583316931015,108.46484138720497,8.959110908870189,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M108(HCBF)-400W,SunSpark Technology Inc,Mono-c-Si,1,400.0,376.5,1.93,,,54.0,13.74,37.1,13.08,30.6,0.0064578,-0.094605,43.6,1.3400739526714545,13.743349133841447,1.297295921947186e-11,0.17963558295680895,736.9645541728028,5.936489830832071,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G54M(H)-405,SunSpark Technology Inc,Mono-c-Si,1,405.0,375.9,1.95,,,54.0,13.86,37.3,12.97,31.2,0.0062369999999999995,-0.11339199999999999,43.8,1.4893608212952796,13.873342463972516,1.8033050157607767e-10,0.11949034549573365,124.12521695710795,9.818082033691994,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST7F54M(H)-405,SunSpark Technology Inc,Mono-c-Si,0,405.0,377.6,1.953,,,54.0,13.86,37.25,12.97,31.24,0.00708246,-0.10407649999999999,44.8,1.4217906663702766,13.875424298451554,5.667224285084568e-11,0.12344424954244082,110.92480604791555,8.838259487183347,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M108(HCBF)-405W,SunSpark Technology Inc,Mono-c-Si,1,405.0,381.3,1.93,,,54.0,13.79,37.4,13.13,30.9,0.0064813,-0.09537,43.6,1.3519264352757847,13.793225637946039,1.3294603270336225e-11,0.17584536069689727,751.7606174448372,6.116590519819704,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G54M(H)-410,SunSpark Technology Inc,Mono-c-Si,1,410.0,380.7,1.95,,,54.0,13.94,37.5,13.05,31.4,0.006273,-0.11399999999999999,43.8,1.49789018681481,13.952857775483245,1.8309366057063383e-10,0.11657404976504676,126.38596008827554,9.900462086217754,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST7F54M(H)-410,SunSpark Technology Inc,Mono-c-Si,0,410.0,382.4,1.953,,,54.0,13.94,37.5,13.05,31.43,0.00712334,-0.104775,44.8,1.430575808123991,13.955398417279534,5.6244013901658534e-11,0.125339061892251,113.46793031618999,8.719090735494536,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M108(HCBF)-410W,SunSpark Technology Inc,Mono-c-Si,1,410.0,386.1,1.93,,,54.0,13.83,37.7,13.18,31.2,0.0065001,-0.09613500000000001,43.6,1.363323493449661,13.832315393058462,1.3495609756915635e-11,0.17222719326122723,1028.7247511503103,6.217975295570683,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G54M(H)-415,SunSpark Technology Inc,Mono-c-Si,1,415.0,385.4,1.95,,,54.0,14.02,37.8,13.13,31.6,0.0063089999999999995,-0.114912,43.8,1.5082213166258647,14.033059574413771,1.7927496411071023e-10,0.12141826479301389,130.3475953683909,9.66137331334975,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST7F54M(H)-415,SunSpark Technology Inc,Mono-c-Si,0,415.0,387.2,1.953,,,54.0,14.02,37.75,13.13,31.64,0.00716422,-0.1054735,44.8,1.4398394215445287,14.035179725698745,5.631155725635182e-11,0.1254525321469757,115.86800389044171,8.677743585530987,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-M108(HCBF)-415W,SunSpark Technology Inc,Mono-c-Si,1,415.0,391.0,1.93,,,54.0,13.87,38.0,13.22,31.4,0.006518899999999999,-0.0969,43.6,1.373048507204791,13.872079169611537,1.3235962183358956e-11,0.17728442513065096,1182.652281963933,6.023765587020478,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M(H)-430,SunSpark Technology Inc,Mono-c-Si,0,430.0,398.3,2.17,,,72.0,11.26,48.8,10.73,40.1,0.0066659200000000005,-0.1475224,45.2,1.8893262992631312,11.26000515055139,6.823504208322175e-11,0.2779832326602271,607753.7887287909,3.6002230518912137,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M-430,SunSpark Technology Inc,Mono-c-Si,0,430.0,398.3,2.17,,,72.0,11.26,48.8,10.73,40.1,0.0066659200000000005,-0.1475224,45.2,1.8893262992631312,11.26000515055139,6.823504208322175e-11,0.2779832326602271,607753.7887287909,3.6002230518912137,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG6I72M-435,SunSpark Technology Inc,Mono-c-Si,1,435.0,402.9,2.17,,,72.0,11.16,49.8,10.51,41.4,0.00837,-0.14840399999999998,45.3,1.9754105174098755,11.167615282038543,1.240430865198151e-10,0.22758913346033838,333.52603675373473,10.23222255203949,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M(H)-435,SunSpark Technology Inc,Mono-c-Si,0,435.0,403.0,2.17,,,72.0,11.33,49.0,10.8,40.3,0.00670736,-0.148127,45.2,1.8981903969478162,11.330003028926814,6.971472472266235e-11,0.26731240897674896,999999.8644702794,3.7279944400806393,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST6L72M-435,SunSpark Technology Inc,Mono-c-Si,0,435.0,403.0,2.17,,,72.0,11.33,49.0,10.8,40.3,0.00670736,-0.148127,45.2,1.8981903969478162,11.330003028926814,6.971472472266235e-11,0.26731240897674896,999999.8644702794,3.7279944400806393,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SG6I72M-440,SunSpark Technology Inc,Mono-c-Si,1,440.0,407.7,2.17,,,72.0,11.22,50.0,10.58,41.6,0.008415,-0.149,45.3,1.9829174205718025,11.226694789898948,1.242128669709642e-10,0.22376714043157386,375.0181068213726,10.192026993155253,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M(H)-440,SunSpark Technology Inc,Mono-c-Si,0,440.0,407.8,2.17,,,72.0,11.4,49.2,10.87,40.5,0.0067488,-0.14873160000000002,45.2,1.9068107977128372,11.400005138326451,7.097887972812942e-11,0.26910858770905305,597082.9866807457,3.827038764800452,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M-440,SunSpark Technology Inc,Mono-c-Si,0,440.0,407.8,2.17,,,72.0,11.4,49.2,10.87,40.5,0.0067488,-0.14873160000000002,45.2,1.9068107977128372,11.400005138326451,7.097887972812942e-11,0.26910858770905305,597082.9866807457,3.827038764800452,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG6I72M-445,SunSpark Technology Inc,Mono-c-Si,1,445.0,412.4,2.17,,,72.0,11.29,50.2,10.65,41.8,0.0084675,-0.149596,45.3,1.9748120326818746,11.290008362095875,1.0300562633720348e-10,0.22273933455119302,300738.8135198491,8.44319731612748,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M(H)-445,SunSpark Technology Inc,Mono-c-Si,0,445.0,412.6,2.17,,,72.0,11.47,49.4,10.94,40.7,0.006790240000000001,-0.1493362,45.2,1.915551623657869,11.47000512902016,7.237299095126621e-11,0.26475706373582336,592107.211801311,3.938909668123056,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST6L72M-445,SunSpark Technology Inc,Mono-c-Si,0,445.0,412.6,2.17,,,72.0,11.47,49.4,10.94,40.7,0.006790240000000001,-0.1493362,45.2,1.915551623657869,11.47000512902016,7.237299095126621e-11,0.26475706373582336,592107.211801311,3.938909668123056,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG6I72M-450,SunSpark Technology Inc,Mono-c-Si,1,450.0,417.2,2.17,,,72.0,11.36,50.4,10.72,42.0,0.00852,-0.150192,45.3,1.9836881859541182,11.360007914562992,1.0499231637348944e-10,0.21858447467912667,313750.9770243568,8.556736198356875,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG6I72M-455,SunSpark Technology Inc,Mono-c-Si,1,455.0,422.0,2.17,,,72.0,11.43,50.6,10.79,42.2,0.0085725,-0.150788,45.3,1.9925604588009402,11.430006499444195,1.0699582925025434e-10,0.21448432164207637,377209.72623750597,8.668952812435753,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG6I72M-460,SunSpark Technology Inc,Mono-c-Si,1,460.0,426.7,2.17,,,72.0,11.5,50.8,10.86,42.4,0.008625,-0.151384,45.3,2.0014339232822604,11.500006084017782,1.0902261675575172e-10,0.210436887535622,397784.19972930994,8.780410869817043,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M132(HCBF)-500W,SunSpark Technology Inc,Mono-c-Si,1,500.0,465.4,2.17,,,66.0,13.91,45.7,13.25,37.8,0.0062594999999999994,-0.13070199999999998,45.5,1.7309025027984761,13.910639708420955,4.7488805960270474e-11,0.19637400421187637,4270.013351527136,4.769649634817445,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M132(HCBF)-505W,SunSpark Technology Inc,Mono-c-Si,1,505.0,470.2,2.17,,,66.0,13.96,45.9,13.3,38.0,0.006282,-0.131274,45.5,1.739146067412781,13.960528704535948,4.815132817023929e-11,0.19353699438640584,5110.18435801016,4.856129487252281,-0.37,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M132(HCBF)-510W,SunSpark Technology Inc,Mono-c-Si,1,510.0,475.0,2.17,,,66.0,14.01,46.1,13.36,38.2,0.0063045,-0.131846,45.5,1.7472956678979035,14.010002658237868,4.877221326816449e-11,0.18972581398060054,999999.8936380455,4.932212358457371,-0.37,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SG7G72M(H)-530,SunSpark Technology Inc,Mono-c-Si,1,530.0,491.7,2.59,,,72.0,13.72,49.3,12.83,41.3,0.006174000000000001,-0.149872,43.8,1.9708841158235155,13.733297185149805,1.8379184611248132e-10,0.15376877262069605,158.65821188551058,10.079713783456267,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M-530,SunSpark Technology Inc,Mono-c-Si,1,530.0,489.1,2.59,,,72.0,13.72,49.3,12.83,41.3,0.007957600000000002,-0.144942,45.4,1.9757711655237404,13.733150997065954,1.9554604700014844e-10,0.15294161463330846,159.55892935741673,14.258417811858958,-0.395,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-530W,SunSpark Technology Inc,Mono-c-Si,1,530.0,490.5,2.56,,,72.0,13.6,49.2,12.79,41.5,0.00272,-0.12890400000000002,45.3,1.8736106831210926,13.610338259779637,5.263754373469015e-11,0.14628260618632546,192.4350427821816,15.98420673057994,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M(H)-535,SunSpark Technology Inc,Mono-c-Si,1,535.0,496.5,2.59,,,72.0,13.79,49.5,12.9,41.5,0.006205499999999999,-0.15048,43.8,1.9793588788143592,13.802903254651604,1.8591516667384927e-10,0.15074219627435886,161.10159788441138,10.135283425809309,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SG7G72M-535,SunSpark Technology Inc,Mono-c-Si,1,535.0,493.9,2.59,,,72.0,13.79,49.5,12.9,41.5,0.0079982,-0.14553,45.4,1.9842629971052212,13.802759105924482,1.9779235495596521e-10,0.14991625470125994,162.02900303633606,14.31569802085827,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-535W,SunSpark Technology Inc,Mono-c-Si,1,535.0,495.3,2.56,,,72.0,13.65,49.5,12.83,41.7,0.0027300000000000002,-0.12969,45.3,1.884317664766735,13.661028420879294,5.2277964489943245e-11,0.15131211328293304,187.28069902843646,15.8883667063965,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M(H)-540,SunSpark Technology Inc,Mono-c-Si,1,540.0,501.2,2.59,,,72.0,13.86,49.6,12.97,41.6,0.0062369999999999995,-0.150784,43.8,1.9834123990261516,13.872622743130632,1.8705822998129062e-10,0.1488941914992751,163.48851680911523,10.143452610439551,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M-540,SunSpark Technology Inc,Mono-c-Si,1,540.0,498.6,2.59,,,72.0,13.86,49.6,12.97,41.6,0.0080388,-0.145824,45.4,1.9883266536260789,13.872479844103756,1.990083426411078e-10,0.14807084411142613,164.44612159905253,14.324246036779424,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-540W,SunSpark Technology Inc,Mono-c-Si,1,540.0,500.1,2.56,,,72.0,13.7,49.8,12.86,42.0,0.00274,-0.130476,45.3,1.8981205533034566,13.711674392691476,5.413850762244947e-11,0.14723822933014497,172.7853274013732,16.187351530613974,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M(H)-545,SunSpark Technology Inc,Mono-c-Si,1,545.0,506.0,2.59,,,72.0,13.93,49.8,13.04,41.8,0.0062685,-0.151392,43.8,1.9918880376362558,13.942242676415438,1.8919761376113152e-10,0.14592646964273834,166.03851242436272,10.198512680907307,-0.402,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M-545,SunSpark Technology Inc,Mono-c-Si,1,545.0,503.4,2.59,,,72.0,13.93,49.8,13.04,41.8,0.0080794,-0.146412,45.4,1.9968192748142157,13.942101805593449,2.0127128512895976e-10,0.14510432014864855,167.0249305342147,14.38099171265818,-0.395,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-545W,SunSpark Technology Inc,Mono-c-Si,1,545.0,504.8,2.56,,,72.0,13.75,50.1,12.9,42.3,0.0027500000000000003,-0.13126200000000002,45.3,1.9111828634568389,13.761769781637078,5.552304663497803e-11,0.14330527489028072,167.41581200259768,16.392375466450165,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M(H)-550,SunSpark Technology Inc,Mono-c-Si,1,550.0,510.8,2.59,,,72.0,14.0,49.9,13.11,42.0,0.0063,-0.151696,43.8,1.9985571572180065,14.011332273606088,1.9663156750423307e-10,0.13525914658753474,167.10045749902005,10.49602161255483,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SG7G72M-550,SunSpark Technology Inc,Mono-c-Si,1,550.0,508.2,2.59,,,72.0,14.0,49.9,13.11,42.0,0.00812,-0.146706,45.4,2.003479138027952,14.011197445669769,2.0909516110764114e-10,0.13444136905166373,168.09005188627722,14.686894239083031,-0.395,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-550W,SunSpark Technology Inc,Mono-c-Si,1,550.0,509.6,2.56,,,72.0,13.8,50.4,12.95,42.5,0.0027600000000000003,-0.132048,45.3,1.9211408414100934,13.811994217614405,5.462800367847317e-11,0.14842082593309427,170.76623765593587,16.204910794275076,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SG7G72M(H)-555,SunSpark Technology Inc,Mono-c-Si,1,555.0,515.6,2.59,,,72.0,14.07,50.1,13.18,42.1,0.0063315,-0.152304,43.8,2.004421092440325,14.081605199657046,1.9250889092086963e-10,0.14121257136956064,171.2043733661788,10.261375162919384,-0.402,N,2025.7.3,6/23/2025,2.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-555W,SunSpark Technology Inc,Mono-c-Si,1,555.0,514.4,2.56,,,72.0,13.85,50.7,12.99,42.8,0.0027700000000000003,-0.132834,45.3,1.9342074661375646,13.862086480464331,5.6011553064225334e-11,0.14451004076242263,165.5952773098159,16.40792558454306,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M144(HCBF)-560W,SunSpark Technology Inc,Mono-c-Si,1,560.0,519.2,2.56,,,72.0,13.9,51.0,13.04,43.0,0.0027800000000000004,-0.13362000000000002,45.3,1.9441640002679796,13.912315042990095,5.511872296098359e-11,0.14958621939731165,168.83810043783134,16.22239889374997,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M156(HCBF)-570W,SunSpark Technology Inc,Mono-c-Si,1,570.0,533.9,2.77,,,78.0,13.56,53.6,12.69,44.9,0.0065088,-0.137752,44.6,1.983200438084706,13.577279693961051,2.4204436147348693e-11,0.19704774225190783,154.63048166952026,10.760937455788511,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M156(HCBF)-580W,SunSpark Technology Inc,Mono-c-Si,1,580.0,543.5,2.77,,,78.0,13.65,54.1,12.79,45.4,0.0065520000000000005,-0.13903700000000002,44.6,2.002301239634909,13.665869240477953,2.4595080737449864e-11,0.19043519026319072,163.80370348877028,10.84063210120051,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M156(HCBF)-585W,SunSpark Technology Inc,Mono-c-Si,1,585.0,548.3,2.77,,,78.0,13.71,54.4,12.84,45.6,0.0065808,-0.13980800000000002,44.6,2.0127278862487796,13.726662192492299,2.4468447220032543e-11,0.19522035336829585,160.63138510888805,10.756492624531083,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M156(HCBF)-590W,SunSpark Technology Inc,Mono-c-Si,1,590.0,553.2,2.77,,,78.0,13.76,54.6,12.89,45.8,0.0066048,-0.140322,44.6,2.0206057308360865,13.776312989572384,2.4720770292163247e-11,0.1923738779681768,162.2672875680281,10.815182826356354,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M156(HCBF)-595W,SunSpark Technology Inc,Mono-c-Si,1,595.0,558.0,2.77,,,78.0,13.81,54.9,12.94,46.0,0.0066288,-0.14109300000000002,44.6,2.0303133768039223,13.826507945816934,2.4363912311569533e-11,0.1973446638342893,165.09200189552556,10.650390480133764,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +SunSpark Technology Inc SST-M156(HCBF)-600W,SunSpark Technology Inc,Mono-c-Si,1,600.0,562.8,2.77,,,78.0,13.86,55.1,12.99,46.3,0.0066528,-0.141607,44.6,2.040418003271233,13.875527487556486,2.5346109834746408e-11,0.18567363325245786,165.73424943529068,10.973328935197225,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +SunStyle M110 870,SunStyle,Mono-c-Si,0,110.0,98.2,0.76,,,24.0,9.2,16.1,8.4,13.1,0.003404,-0.045241,50.24,0.6335955076017253,9.234218021855561,8.077940850633449e-11,0.12874602701247043,34.61519397080527,15.356833298578549,-0.401,Y,2025.7.3,6/23/2025,4.0,first_pass +SUNSTYLE AG / LTD SUNSTYLE M75,SUNSTYLE AG / LTD,Mono-c-Si,0,75.0,68.2,0.715,,,24.0,6.3,15.6,6.0,12.5,0.0020916,-0.05109,43.3,0.6244093919172553,6.30000125947452,8.893979133654251e-11,0.1998245209967187,999999.2897115488,2.639141129766918,-0.4379,Y,2025.7.3,6/23/2025,2.0,first_pass +SUNSTYLE AG / LTD SUNSTYLE M80,SUNSTYLE AG / LTD,Mono-c-Si,0,80.0,72.8,0.715,,,24.0,6.6,15.7,6.4,12.6,0.0021912,-0.051417500000000005,43.3,0.6341409779289829,6.600098704078176,1.1673948378763083e-10,0.13726846259561323,9178.701117797717,4.5151114746327305,-0.4379,Y,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP170S-24/Ad+,Suntech Power,Mono-c-Si,0,170.0,151.4,1.2766400000000002,1.58,0.808,72.0,5.14,43.8,4.83,35.2,0.0021588,-0.160746,45.3,1.8940219267676657,5.142490205158676,4.6255625669913203e-10,0.6470070365038196,1335.480028425,6.178122418094231,-0.499,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP170S-24/Adb+,Suntech Power,Mono-c-Si,0,170.0,152.9,1.2766400000000002,1.58,0.808,72.0,5.14,43.8,4.83,35.2,0.0022616,-0.141036,46.4,1.7701644388005753,5.14447261145543,9.136222374528816e-11,0.6994816779456458,803.8561692191859,6.250908108669465,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP175S-24/Ad+,Suntech Power,Mono-c-Si,0,175.0,156.0,1.2766400000000002,1.58,0.808,72.0,5.2,44.2,4.95,35.2,0.002184,-0.16221400000000002,45.3,1.9052053707678736,5.2000033821817615,4.3706119276830216e-10,0.6500079214928834,999999.712625205,5.575714080629608,-0.499,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP175S-24/Adb+,Suntech Power,Mono-c-Si,0,175.0,157.5,1.2766400000000002,1.58,0.808,72.0,5.2,44.2,4.95,35.2,0.002288,-0.14232400000000003,46.4,1.7753364511428347,5.200003794711457,8.007652071964548e-11,0.729636857744683,999999.7248772379,5.000408903257772,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP180S-24/Ad+,Suntech Power,Mono-c-Si,0,180.0,160.5,1.2766400000000002,1.58,0.808,72.0,5.4,44.4,5.05,35.6,0.0022680000000000005,-0.162948,45.3,1.9223391137564472,5.405183701116472,4.972935774955629e-10,0.6430765586194657,669.9103659364265,6.392583364887415,-0.499,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP180S-24/Adb+,Suntech Power,Mono-c-Si,0,180.0,162.1,1.2766400000000002,1.58,0.808,72.0,5.4,44.4,5.05,35.6,0.002376,-0.142968,46.4,1.796500599705484,5.407518849306592,9.824719571343053e-11,0.6940263971437649,498.4463361251107,6.467499101045169,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP185S-24/Ad+,Suntech Power,Mono-c-Si,0,185.0,165.1,1.2766400000000002,1.58,0.808,72.0,5.4,45.3,5.2,35.6,0.0022680000000000005,-0.16625099999999998,45.3,1.9507995755151801,5.400003398018165,4.4415104229803465e-10,0.6288753766877461,999999.1928552175,5.391162450066287,-0.499,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP185S-24/Adb,Suntech Power,Mono-c-Si,0,185.0,167.2,1.2766400000000002,1.58,0.808,72.0,5.43,45.0,5.09,36.4,0.0029865,-0.1467,45.8,1.8483395999272108,5.435575343819585,1.4315763318191806e-10,0.617351712675891,601.2580320083779,8.201316365379716,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP185S-24/Adb+,Suntech Power,Mono-c-Si,0,185.0,167.2,1.2766400000000002,1.58,0.808,72.0,5.43,45.0,5.09,36.4,0.0029865,-0.1467,45.8,1.8483395999272108,5.435575343819585,1.4315763318191806e-10,0.617351712675891,601.2580320083779,8.201316365379716,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP190S-24/Ad,Suntech Power,Mono-c-Si,0,190.0,171.5,1.2766400000000002,1.58,0.808,72.0,5.62,45.2,5.2,36.6,0.0019108,-0.147352,46.1,1.8372889204795846,5.6331974682521775,1.1289439015750553e-10,0.6023735887855238,256.5143297290052,6.163052893336598,-0.437,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP190S-24/Ad+,Suntech Power,Mono-c-Si,0,190.0,171.5,1.2766400000000002,1.58,0.808,72.0,5.62,45.2,5.2,36.6,0.0019108,-0.147352,46.1,1.8372889204795846,5.6331974682521775,1.1289439015750553e-10,0.6023735887855238,256.5143297290052,6.163052893336598,-0.437,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP190S-24/Adb,Suntech Power,Mono-c-Si,0,190.0,171.8,1.2766400000000002,1.58,0.808,72.0,5.62,45.2,5.2,36.6,0.003091,-0.147352,45.8,1.8705486110129697,5.632476525494883,1.7500639344800767e-10,0.5889967712945579,265.31121040798547,9.712848586853188,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP190S-24/Adb+,Suntech Power,Mono-c-Si,0,190.0,171.8,1.2766400000000002,1.58,0.808,72.0,5.62,45.2,5.2,36.6,0.003091,-0.147352,45.8,1.8705486110129697,5.632476525494883,1.7500639344800767e-10,0.5889967712945579,265.31121040798547,9.712848586853188,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP195S-24/Ad,Suntech Power,Mono-c-Si,0,195.0,176.2,1.2766400000000002,1.58,0.808,72.0,5.69,45.4,5.33,36.6,0.0019346000000000003,-0.148004,46.1,1.8289272485877461,5.696954380974265,9.296169862354524e-11,0.6344641000774953,519.11177169181,4.366995105891579,-0.437,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP195S-24/Ad+,Suntech Power,Mono-c-Si,0,195.0,176.2,1.2766400000000002,1.58,0.808,72.0,5.69,45.4,5.33,36.6,0.0019346000000000003,-0.148004,46.1,1.8289272485877461,5.696954380974265,9.296169862354524e-11,0.6344641000774953,519.11177169181,4.366995105891579,-0.437,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP195S-24/Adb,Suntech Power,Mono-c-Si,0,195.0,176.5,1.2766400000000002,1.58,0.808,72.0,5.69,45.4,5.33,36.6,0.0031295000000000003,-0.148004,45.8,1.861872890379453,5.696340396988719,1.443738135820064e-10,0.6216158350981531,557.8506465344428,7.868607248610439,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP195S-24/Adb+,Suntech Power,Mono-c-Si,0,195.0,176.5,1.2766400000000002,1.58,0.808,72.0,5.69,45.4,5.33,36.6,0.0031295000000000003,-0.148004,45.8,1.861872890379453,5.696340396988719,1.443738135820064e-10,0.6216158350981531,557.8506465344428,7.868607248610439,-0.436,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP210-20/Wd,Suntech Power,Multi-c-Si,0,210.0,190.0,1.650015,1.665,0.991,60.0,7.86,36.4,7.25,29.0,0.0033798,-0.113568,45.9,1.4472159592381215,7.88533412393882,9.083625709768406e-11,0.4298505483246035,133.36263100503314,6.024528377882875,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP210-20/Wde,Suntech Power,Multi-c-Si,0,210.0,190.0,1.650015,1.665,0.991,60.0,7.86,36.4,7.25,29.0,0.0033798,-0.113568,45.9,1.4472159592381215,7.88533412393882,9.083625709768406e-11,0.4298505483246035,133.36263100503314,6.024528377882875,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP215-20/Wd,Suntech Power,Multi-c-Si,0,215.0,194.7,1.650015,1.665,0.991,60.0,7.95,36.5,7.37,29.2,0.0034184999999999997,-0.11388,45.9,1.4508063918548217,7.970206473989258,9.176900256372191e-11,0.4067438750179454,160.02860912871725,5.997988511200296,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP215-20/Wde,Suntech Power,Multi-c-Si,0,215.0,194.7,1.650015,1.665,0.991,60.0,7.95,36.5,7.37,29.2,0.0034184999999999997,-0.11388,45.9,1.4508063918548217,7.970206473989258,9.176900256372191e-11,0.4067438750179454,160.02860912871725,5.997988511200296,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP220-20/Wd,Suntech Power,Multi-c-Si,0,220.0,199.3,1.650015,1.665,0.991,60.0,8.05,36.6,7.46,29.5,0.0034614999999999997,-0.11419200000000002,45.9,1.461193175217936,8.069446044997116,1.0363438644862289e-10,0.3681372289483725,152.39627378203681,6.937292166529991,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP220-20/Wde,Suntech Power,Multi-c-Si,0,220.0,199.3,1.650015,1.665,0.991,60.0,8.05,36.6,7.46,29.5,0.0034614999999999997,-0.11419200000000002,45.9,1.461193175217936,8.069446044997116,1.0363438644862289e-10,0.3681372289483725,152.39627378203681,6.937292166529991,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP225-20/Wd,Suntech Power,Multi-c-Si,0,225.0,203.9,1.650015,1.665,0.991,60.0,8.15,36.7,7.61,29.6,0.0035045,-0.11450400000000001,45.9,1.4600090059236182,8.163309194923643,9.686669070888273e-11,0.361746786793066,221.51876724832204,6.223941033584159,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP225-20/Wde,Suntech Power,Multi-c-Si,0,225.0,203.9,1.650015,1.665,0.991,60.0,8.15,36.7,7.61,29.6,0.0035045,-0.11450400000000001,45.9,1.4600090059236182,8.163309194923643,9.686669070888273e-11,0.361746786793066,221.51876724832204,6.223941033584159,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP230-20/Wd,Suntech Power,Multi-c-Si,0,230.0,208.6,1.650015,1.665,0.991,60.0,8.25,36.8,7.72,29.8,0.0035475,-0.114816,45.9,1.4656359345375176,8.26132718327752,1.0108008377126937e-10,0.3402479404569054,247.81497617424094,6.477346292438659,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP230-20/Wde,Suntech Power,Multi-c-Si,0,230.0,208.6,1.650015,1.665,0.991,60.0,8.25,36.8,7.72,29.8,0.0035475,-0.114816,45.9,1.4656359345375176,8.26132718327752,1.0108008377126937e-10,0.3402479404569054,247.81497617424094,6.477346292438659,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP230S-20/Wd,Suntech Power,Mono-c-Si,0,230.0,207.7,1.6268799999999999,1.64,0.992,60.0,8.25,36.8,7.72,29.8,0.005874,-0.1477152,46.1,1.5465051260560814,8.258730987147473,3.7682583333619923e-10,0.3184237469215252,300.88194720582163,-8.451216384348424,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP230S-20/Wdb,Suntech Power,Mono-c-Si,0,230.0,207.7,1.6268799999999999,1.64,0.992,60.0,8.25,36.8,7.72,29.8,0.005874,-0.1477152,46.1,1.5465051260560814,8.258730987147473,3.7682583333619923e-10,0.3184237469215252,300.88194720582163,-8.451216384348424,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP230S-20/Wde,Suntech Power,Mono-c-Si,0,230.0,207.7,1.6268799999999999,1.64,0.992,60.0,8.25,36.8,7.72,29.8,0.005874,-0.1477152,46.1,1.5465051260560814,8.258730987147473,3.7682583333619923e-10,0.3184237469215252,300.88194720582163,-8.451216384348424,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP235-20/Wd,Suntech Power,Multi-c-Si,0,235.0,213.9,1.650015,1.665,0.991,60.0,8.35,37.0,7.79,30.2,0.004717750000000001,-0.1257926,43.7,1.5589161692221982,8.36043032573444,4.035328446581172e-10,0.281488719683895,225.34589896166787,8.921462384920622,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP235-20/Wde,Suntech Power,Multi-c-Si,0,235.0,213.9,1.650015,1.665,0.991,60.0,8.35,37.0,7.79,30.2,0.004717750000000001,-0.1257926,43.7,1.5589161692221982,8.36043032573444,4.035328446581172e-10,0.281488719683895,225.34589896166787,8.921462384920622,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP235S-20/Wd,Suntech Power,Mono-c-Si,0,235.0,212.4,1.6268799999999999,1.64,0.992,60.0,8.35,37.0,7.79,30.2,0.0059452,-0.14851799999999998,46.1,1.5651072148290663,8.360246178600775,4.433495652999562e-10,0.2798379778510804,228.05061726247027,-7.317481925075863,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP235S-20/Wdb,Suntech Power,Mono-c-Si,0,235.0,212.4,1.6268799999999999,1.64,0.992,60.0,8.35,37.0,7.79,30.2,0.0059452,-0.14851799999999998,46.1,1.5651072148290663,8.360246178600775,4.433495652999562e-10,0.2798379778510804,228.05061726247027,-7.317481925075863,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP235S-20/Wde,Suntech Power,Mono-c-Si,0,235.0,212.4,1.6268799999999999,1.64,0.992,60.0,8.35,37.0,7.79,30.2,0.0059452,-0.14851799999999998,46.1,1.5651072148290663,8.360246178600775,4.433495652999562e-10,0.2798379778510804,228.05061726247027,-7.317481925075863,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP240-20/Wd,Suntech Power,Multi-c-Si,0,240.0,218.6,1.650015,1.665,0.991,60.0,8.43,37.2,7.95,30.2,0.00476295,-0.12647256,43.7,1.5534508662004134,8.433189423719734,3.339652930677007e-10,0.3057635755616073,808.167343392582,7.145332195974406,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP240-20/Wdb,Suntech Power,Multi-c-Si,0,240.0,220.0,1.6268799999999999,1.64,0.992,60.0,8.43,37.2,7.95,30.2,0.00795792,-0.15594240000000004,43.3,1.5991569795648997,8.432065516652058,6.63230252232046e-10,0.29395734725465705,1199.730531336864,-8.707800249849843,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP240-20/Wde,Suntech Power,Multi-c-Si,0,240.0,218.6,1.650015,1.665,0.991,60.0,8.43,37.2,7.95,30.2,0.00476295,-0.12647256,43.7,1.5534508662004134,8.433189423719734,3.339652930677007e-10,0.3057635755616073,808.167343392582,7.145332195974406,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP240S-20/Wd,Suntech Power,Mono-c-Si,0,240.0,217.0,1.6268799999999999,1.64,0.992,60.0,8.43,37.2,7.95,30.2,0.00600216,-0.1493208,46.1,1.5589941618850718,8.433048622423879,3.6372011885439247e-10,0.30432446603746155,841.5133646188008,-8.89311237655645,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP240S-20/Wdb,Suntech Power,Mono-c-Si,0,240.0,217.0,1.6268799999999999,1.64,0.992,60.0,8.43,37.2,7.95,30.2,0.00600216,-0.1493208,46.1,1.5589941618850718,8.433048622423879,3.6372011885439247e-10,0.30432446603746155,841.5133646188008,-8.89311237655645,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP240S-20/Wde,Suntech Power,Mono-c-Si,0,240.0,217.0,1.6268799999999999,1.64,0.992,60.0,8.43,37.2,7.95,30.2,0.00600216,-0.1493208,46.1,1.5589941618850718,8.433048622423879,3.6372011885439247e-10,0.30432446603746155,841.5133646188008,-8.89311237655645,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP245-20/Wd,Suntech Power,Multi-c-Si,0,245.0,223.3,1.6268799999999999,1.64,0.992,60.0,8.52,37.3,8.04,30.5,0.0048138,-0.12681254,43.7,1.5632444058773747,8.522903045132798,3.678357800039769e-10,0.27141943435707294,796.575481165525,7.8924618489344445,-0.450002,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP245-20/Wdb,Suntech Power,Multi-c-Si,0,245.0,224.7,1.6268799999999999,1.64,0.992,60.0,8.52,37.3,8.04,30.5,0.008042879999999999,-0.15636160000000002,43.3,1.6100908712277526,8.521876017622883,7.377026948837036e-10,0.2593899287277266,1178.029846633556,-7.992228007779252,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP245-20/Wde,Suntech Power,Multi-c-Si,0,245.0,223.3,1.6268799999999999,1.64,0.992,60.0,8.52,37.3,8.04,30.5,0.0048138,-0.12681254,43.7,1.5635478036296842,8.522896113217326,3.695468012295464e-10,0.2713410736436123,798.2515781250828,7.932886772993729,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP245S-20/Wd,Suntech Power,Mono-c-Si,0,245.0,221.6,1.6268799999999999,1.64,0.992,60.0,8.52,37.3,8.04,30.5,0.00606624,-0.1497222,46.1,1.5694366151794017,8.522762296779534,4.0423594536522554e-10,0.2698213108937034,832.2331286859019,-8.189507404526534,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP245S-20/Wdb,Suntech Power,Mono-c-Si,0,245.0,221.6,1.6268799999999999,1.64,0.992,60.0,8.52,37.3,8.04,30.5,0.00606624,-0.1497222,46.1,1.5694366151794017,8.522762296779534,4.0423594536522554e-10,0.2698213108937034,832.2331286859019,-8.189507404526534,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP245S-20/Wde,Suntech Power,Mono-c-Si,0,245.0,221.6,1.6268799999999999,1.64,0.992,60.0,8.52,37.3,8.04,30.5,0.00606624,-0.1497222,46.1,1.5694366151794017,8.522762296779534,4.0423594536522554e-10,0.2698213108937034,832.2331286859019,-8.189507404526534,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250-20/Wd,Suntech Power,Multi-c-Si,0,250.0,228.0,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.004875950000000001,-0.12715252,43.7,1.5702695446107855,8.632492577408282,3.891650140653051e-10,0.25169592493127835,871.4420816959528,8.271272045095222,-0.450002,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250-20/Wdb,Suntech Power,Multi-c-Si,0,250.0,229.4,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.008146720000000001,-0.1567808,43.3,1.6175868197663643,8.631527752633241,7.824078451551599e-10,0.23967683763289993,1353.8931690785332,-7.647511265784562,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250-20/Wde,Suntech Power,Multi-c-Si,0,250.0,228.0,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.004875950000000001,-0.12715252,43.7,1.5705744823218666,8.632486076452066,3.909730095500142e-10,0.25161801582664095,873.4504098653242,8.311795400773011,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250-20/Wem,Suntech Power,Multi-c-Si,0,250.0,228.1,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.005229780000000001,-0.1275714,43.8,1.569479871148294,8.632509429630039,3.8451854243376134e-10,0.25189770761224384,866.2837914871891,7.760910807467027,-0.4457,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250S-20/Wd,Suntech Power,Mono-c-Si,0,250.0,226.3,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.006144560000000001,-0.1501236,46.1,1.576640050216915,8.632357532881395,4.285742138967678e-10,0.2500695451068205,915.4066487046216,-7.850665572474896,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250S-20/Wdb,Suntech Power,Mono-c-Si,0,250.0,226.3,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.006144560000000001,-0.1501236,46.1,1.576640050216915,8.632357532881395,4.285742138967678e-10,0.2500695451068205,915.4066487046216,-7.850665572474896,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP250S-20/Wde,Suntech Power,Mono-c-Si,0,250.0,226.3,1.6268799999999999,1.64,0.992,60.0,8.63,37.4,8.15,30.7,0.006144560000000001,-0.1501236,46.1,1.576640050216915,8.632357532881395,4.285742138967678e-10,0.2500695451068205,915.4066487046216,-7.850665572474896,-0.4301,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP255-20/Wd,Suntech Power,Multi-c-Si,0,255.0,232.7,1.6268799999999999,1.64,0.992,60.0,8.73,37.5,8.26,30.9,0.0049324500000000005,-0.1274925,43.7,1.576327217437501,8.731437087966935,4.0562719474059305e-10,0.23294412524916513,1415.0863910875585,8.527587947100862,-0.450002,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP255-20/Wdb,Suntech Power,Multi-c-Si,0,255.0,234.1,1.6268799999999999,1.64,0.992,60.0,8.73,37.5,8.26,30.9,0.00824112,-0.1572,43.3,1.6240125173170759,8.730570470469502,8.16989103158656e-10,0.2209636645248693,3381.4530160117724,-7.412183102809487,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP255-20/Wde,Suntech Power,Multi-c-Si,0,255.0,232.7,1.6268799999999999,1.64,0.992,60.0,8.73,37.5,8.26,30.9,0.0049324500000000005,-0.1274925,43.7,1.576633466640266,8.731431238716839,4.07510270693312e-10,0.23286673322032417,1420.3973054794042,8.568182094074752,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP255-20/Wem,Suntech Power,Multi-c-Si,0,255.0,232.8,1.6268799999999999,1.64,0.992,60.0,8.76,37.6,8.28,30.8,0.00530856,-0.1282536,43.8,1.5752578902916692,8.761936615765423,3.756496184651995e-10,0.2587158412110226,1170.2642427312915,7.423917852638703,-0.4457,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP255S-20/Wdb,Suntech Power,Mono-c-Si,0,255.0,232.7,1.6268799999999999,1.64,0.992,60.0,8.73,37.5,8.26,30.9,0.0049324500000000005,-0.1274925,43.7,1.576633466640266,8.731431238716839,4.07510270693312e-10,0.23286673322032417,1420.3973054794042,8.568182094074752,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP255S-20/Wde,Suntech Power,Mono-c-Si,0,255.0,232.7,1.6268799999999999,1.64,0.992,60.0,8.73,37.5,8.26,30.9,0.0049324500000000005,-0.1274925,43.7,1.576633466640266,8.731431238716839,4.07510270693312e-10,0.23286673322032417,1420.3973054794042,8.568182094074752,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260-20/Wd,Suntech Power,Multi-c-Si,0,260.0,237.3,1.6268799999999999,1.64,0.992,60.0,8.83,37.6,8.37,31.1,0.004988950000000001,-0.12783248,43.7,1.5823938094168855,8.83051625384046,4.2267614728845806e-10,0.21469034897111974,3672.0597197422667,8.783481628940704,-0.450002,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260-20/Wdb,Suntech Power,Multi-c-Si,0,260.0,238.8,1.6268799999999999,1.64,0.992,60.0,8.83,37.6,8.37,31.1,0.00833552,-0.15761920000000001,43.3,1.6312230370370833,8.830001963164449,8.617646946865018e-10,0.20257237947529338,911936.3231143106,-7.097397662400093,-0.4303,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260-20/Wde,Suntech Power,Multi-c-Si,0,260.0,237.3,1.6268799999999999,1.64,0.992,60.0,8.83,37.6,8.37,31.1,0.004988950000000001,-0.12783248,43.7,1.582701340236777,8.830511057324236,4.2463670871164905e-10,0.2146134678936574,3708.078244794753,8.824143675501666,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260-20/Wem,Suntech Power,Multi-c-Si,0,260.0,237.4,1.6268799999999999,1.64,0.992,60.0,8.89,37.7,8.42,30.9,0.005387340000000001,-0.12859470000000003,43.8,1.578271842424056,8.890620488900549,3.7538894073879545e-10,0.253320179249275,3629.429295605486,7.282814434250278,-0.4457,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260-24/Vd,Suntech Power,Multi-c-Si,0,260.0,235.4,1.9403519999999999,1.956,0.992,72.0,8.09,44.0,7.47,34.8,0.0043686,-0.13772,46.1,1.755172090515901,8.11592865171993,1.0184442195466399e-10,0.5411410265686656,168.84144780292382,6.266506559832613,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260-24/Ve,Suntech Power,Multi-c-Si,0,260.0,235.4,1.9403519999999999,1.956,0.992,72.0,8.09,44.0,7.47,34.8,0.0043686,-0.13772,46.1,1.755172090515901,8.11592865171993,1.0184442195466399e-10,0.5411410265686656,168.84144780292382,6.266506559832613,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260S-20/Wdb,Suntech Power,Mono-c-Si,0,260.0,237.3,1.6268799999999999,1.64,0.992,60.0,8.83,37.6,8.37,31.1,0.004988950000000001,-0.12783248,43.7,1.582701340236777,8.830511057324236,4.2463670871164905e-10,0.2146134678936574,3708.078244794753,8.824143675501666,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP260S-20/Wde,Suntech Power,Mono-c-Si,0,260.0,237.3,1.6268799999999999,1.64,0.992,60.0,8.83,37.6,8.37,31.1,0.004988950000000001,-0.12783248,43.7,1.582701340236777,8.830511057324236,4.2463670871164905e-10,0.2146134678936574,3708.078244794753,8.824143675501666,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP265-20/Wd,Suntech Power,Multi-c-Si,0,265.0,242.0,1.6268799999999999,1.64,0.992,60.0,8.93,37.7,8.47,31.3,0.005045450000000001,-0.12817246000000002,43.7,1.5894750587188131,8.93033771199829,4.463667088302653e-10,0.19670187553138413,5201.3261447609475,9.163599153774527,-0.450002,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP265-20/Wde,Suntech Power,Multi-c-Si,0,265.0,242.0,1.6268799999999999,1.64,0.992,60.0,8.93,37.7,8.47,31.3,0.005045450000000001,-0.12817246000000002,43.7,1.5897841786756601,8.93033293556366,4.4843481770868193e-10,0.19662531006915418,5273.899760113279,9.204362879069302,-0.4502,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP265-20/Wem,Suntech Power,Multi-c-Si,0,265.0,242.1,1.6268799999999999,1.64,0.992,60.0,9.02,37.8,8.56,31.0,0.0054661200000000005,-0.12893580000000002,43.8,1.5820830420659064,9.028969558494317,3.7951876076387866e-10,0.24773808542215722,999999.979580779,7.240512123099518,-0.4457,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP265S-20/Web,Suntech Power,Mono-c-Si,0,265.0,242.0,1.6268799999999999,1.64,0.992,60.0,9.22,38.1,8.69,30.5,0.004720640000000001,-0.12051030000000001,44.1,1.5504358374707743,9.224404492120552,1.9509922799771763e-10,0.3514464749559667,735.6892519855152,9.603869338554423,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP270-20/Wem,Suntech Power,Multi-c-Si,0,270.0,246.8,1.6268799999999999,1.64,0.992,60.0,9.15,37.9,8.69,31.1,0.005544900000000001,-0.1292769,43.8,1.5866872501668932,9.165579224770028,3.876982416610854e-10,0.24227858430522448,999999.9796864365,7.295696080212462,-0.4457,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP270-24/Vd,Suntech Power,Multi-c-Si,0,270.0,244.7,1.9403519999999999,1.956,0.992,72.0,8.2,44.5,7.71,35.0,0.004428,-0.139285,46.1,1.753652440803008,8.206844673803205,7.766297648873419e-11,0.5679400937065915,680.399037503119,3.79078310166601,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP270-24/Vdx,Suntech Power,Multi-c-Si,0,270.0,244.7,1.9403519999999999,1.956,0.992,72.0,8.2,44.5,7.71,35.0,0.004428,-0.139285,46.1,1.753652440803008,8.206844673803205,7.766297648873419e-11,0.5679400937065915,680.399037503119,3.79078310166601,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP270-24/Ve,Suntech Power,Multi-c-Si,0,270.0,244.7,1.9403519999999999,1.956,0.992,72.0,8.2,44.5,7.71,35.0,0.004428,-0.139285,46.1,1.753652440803008,8.206844673803205,7.766297648873419e-11,0.5679400937065915,680.399037503119,3.79078310166601,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP270S-20/Web,Suntech Power,Mono-c-Si,0,270.0,246.7,1.6268799999999999,1.64,0.992,60.0,9.28,38.3,8.77,30.8,0.00475136,-0.12114290000000001,44.1,1.5604349854336146,9.282042669965428,2.0274049861367501e-10,0.3322027138856766,1509.2219827437336,9.877831019774261,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP275-24/Vd,Suntech Power,Multi-c-Si,0,275.0,249.3,1.9403519999999999,1.956,0.992,72.0,8.26,44.7,7.84,35.1,0.0044604,-0.139911,46.1,1.7577978799476146,8.260004598220737,7.46563820244075e-11,0.5565706998274698,999999.9338760846,3.37851871336078,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP275-24/Vdx,Suntech Power,Multi-c-Si,0,275.0,249.3,1.9403519999999999,1.956,0.992,72.0,8.26,44.7,7.84,35.1,0.0044604,-0.139911,46.1,1.7577978799476146,8.260004598220737,7.46563820244075e-11,0.5565706998274698,999999.9338760846,3.37851871336078,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP275-24/Ve,Suntech Power,Multi-c-Si,0,275.0,249.3,1.9403519999999999,1.956,0.992,72.0,8.26,44.7,7.84,35.1,0.0044604,-0.139911,46.1,1.7577978799476146,8.260004598220737,7.46563820244075e-11,0.5565706998274698,999999.9338760846,3.37851871336078,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP275S-20/Web,Suntech Power,Mono-c-Si,0,275.0,251.4,1.6268799999999999,1.64,0.992,60.0,9.34,38.5,8.85,31.1,0.00478208,-0.12177550000000001,44.1,1.570465789096801,9.340677440736888,2.106874847803271e-10,0.3133062991144446,999999.9263181008,10.152784198570314,-0.4402,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP275S-20/Wem,Suntech Power,Mono-c-Si,0,275.0,251.8,1.6268799999999999,1.64,0.992,60.0,9.34,38.5,8.85,31.1,0.00489416,-0.12681900000000002,44.4,1.5541144621417033,9.340391015840293,1.6269461213155843e-10,0.31714982359248334,7575.617384692376,3.5516236271363804,-0.4267,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP275S-20/Wew,Suntech Power,Mono-c-Si,0,275.0,251.8,1.6268799999999999,1.64,0.992,60.0,9.34,38.5,8.85,31.1,0.00489416,-0.12681900000000002,44.4,1.5541144621417033,9.340391015840293,1.6269461213155843e-10,0.31714982359248334,7575.617384692376,3.5516236271363804,-0.4267,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP280-24/Vd,Suntech Power,Multi-c-Si,0,280.0,254.0,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.95,35.2,0.0044982,-0.140224,46.1,1.7666046710266492,8.33000434458661,8.076140910671685e-11,0.5214524168538391,999994.3410253816,3.9650757200505935,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP280-24/Vdx,Suntech Power,Multi-c-Si,0,280.0,254.0,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.95,35.2,0.0044982,-0.140224,46.1,1.7666046710266492,8.33000434458661,8.076140910671685e-11,0.5214524168538391,999994.3410253816,3.9650757200505935,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP280-24/Ve,Suntech Power,Multi-c-Si,0,280.0,254.0,1.9403519999999999,1.956,0.992,72.0,8.33,44.8,7.95,35.2,0.0044982,-0.140224,46.1,1.7666046710266492,8.33000434458661,8.076140910671685e-11,0.5214524168538391,999994.3410253816,3.9650757200505935,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP280S-20/Web,Suntech Power,Mono-c-Si,0,280.0,256.1,1.6268799999999999,1.64,0.992,60.0,9.41,39.4,8.89,31.5,0.004817920000000001,-0.12462220000000002,44.1,1.6002877291022846,9.411952815041033,1.9057059460799656e-10,0.3614466815506107,1741.698768730628,9.207427313571813,-0.4402,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP280S-20/Wem,Suntech Power,Mono-c-Si,0,280.0,256.5,1.6268799999999999,1.64,0.992,60.0,9.41,39.4,8.89,31.5,0.004930840000000001,-0.12978360000000003,44.4,1.5836369728157562,9.41250798334501,1.4701909909472164e-10,0.3653027604793813,1370.6233593456589,2.654790429304354,-0.4267,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP280S-20/Wew,Suntech Power,Mono-c-Si,0,280.0,256.5,1.6268799999999999,1.64,0.992,60.0,9.41,39.4,8.89,31.5,0.004930840000000001,-0.12978360000000003,44.4,1.5836369728157562,9.41250798334501,1.4701909909472164e-10,0.3653027604793813,1370.6233593456589,2.654790429304354,-0.4267,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP285-24/Vd,Suntech Power,Multi-c-Si,0,285.0,258.6,1.9403519999999999,1.956,0.992,72.0,8.37,44.8,7.95,35.8,0.0045198,-0.140224,46.1,1.776314209823437,8.370003880261667,9.321484055128452e-11,0.4635033488989064,999999.8657971133,5.133542413949579,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP285-24/Vdx,Suntech Power,Multi-c-Si,0,285.0,258.6,1.9403519999999999,1.956,0.992,72.0,8.37,44.8,7.95,35.8,0.0045198,-0.140224,46.1,1.776314209823437,8.370003880261667,9.321484055128452e-11,0.4635033488989064,999999.8657971133,5.133542413949579,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP285-24/Ve,Suntech Power,Multi-c-Si,0,285.0,258.6,1.9403519999999999,1.956,0.992,72.0,8.37,44.8,7.95,35.8,0.0045198,-0.140224,46.1,1.776314209823437,8.370003880261667,9.321484055128452e-11,0.4635033488989064,999999.8657971133,5.133542413949579,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP285-24/Ver,Suntech Power,Multi-c-Si,0,285.0,258.6,1.9403519999999999,1.956,0.992,72.0,8.37,44.8,7.95,35.8,0.0045198,-0.140224,46.1,1.776314209823437,8.370003880261667,9.321484055128452e-11,0.4635033488989064,999999.8657971133,5.133542413949579,-0.415,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP285S-20/Web,Suntech Power,Mono-c-Si,0,285.0,260.8,1.6268799999999999,1.64,0.992,60.0,9.48,39.6,9.02,31.6,0.00485376,-0.12525480000000003,44.1,1.6094075407254465,9.480003291310338,1.9536583273145177e-10,0.3470388787144109,999985.1053784726,9.353929724227731,-0.4402,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP285S-20/Wem,Suntech Power,Mono-c-Si,0,285.0,261.2,1.6268799999999999,1.64,0.992,60.0,9.48,39.6,9.02,31.6,0.0049675200000000004,-0.13044240000000001,44.4,1.5919071356110805,9.480003346652452,1.4906443984579575e-10,0.3529094245802007,999999.8135067361,2.699375874430134,-0.4267,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP285S-20/Wew,Suntech Power,Mono-c-Si,0,285.0,261.2,1.6268799999999999,1.64,0.992,60.0,9.48,39.6,9.02,31.6,0.0049675200000000004,-0.13044240000000001,44.4,1.5919071356110805,9.480003346652452,1.4906443984579575e-10,0.3529094245802007,999999.8135067361,2.699375874430134,-0.4267,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP290-24/Vd,Suntech Power,Multi-c-Si,0,290.0,263.3,1.9403519999999999,1.956,0.992,72.0,8.4,44.8,7.95,36.5,0.004536,-0.140224,46.1,1.7943418005388259,8.402240251276249,1.2009753813651418e-10,0.37075249960234197,1390.1662473387628,7.284043494339991,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP290-24/Vdx,Suntech Power,Multi-c-Si,0,290.0,263.3,1.9403519999999999,1.956,0.992,72.0,8.4,44.8,7.95,36.5,0.004536,-0.140224,46.1,1.7943418005388259,8.402240251276249,1.2009753813651418e-10,0.37075249960234197,1390.1662473387628,7.284043494339991,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP290-24/Ve,Suntech Power,Multi-c-Si,0,290.0,263.3,1.9403519999999999,1.956,0.992,72.0,8.4,44.8,7.95,36.5,0.004536,-0.140224,46.1,1.7943418005388259,8.402240251276249,1.2009753813651418e-10,0.37075249960234197,1390.1662473387628,7.284043494339991,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP290-24/Ver,Suntech Power,Multi-c-Si,0,290.0,263.3,1.9403519999999999,1.956,0.992,72.0,8.4,44.8,7.95,36.5,0.004536,-0.140224,46.1,1.7943418005388259,8.402240251276249,1.2009753813651418e-10,0.37075249960234197,1390.1662473387628,7.284043494339991,-0.415,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP290S-20/Web,Suntech Power,Mono-c-Si,0,290.0,265.5,1.6268799999999999,1.64,0.992,60.0,9.55,39.8,9.15,31.7,0.004889600000000001,-0.1258874,44.1,1.621781386244561,9.55028446639537,2.0982849745556907e-10,0.3216437394323324,10798.148693753245,9.921115959704009,-0.4402,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP290S-20/Wem,Suntech Power,Mono-c-Si,0,290.0,265.9,1.6268799999999999,1.64,0.992,60.0,9.55,39.8,9.15,31.7,0.005004200000000001,-0.1311012,44.4,1.6041919376508482,9.550289168701624,1.6032591410264904e-10,0.3277594258746423,10824.521834065914,3.243708268301349,-0.4267,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP290S-20/Wew,Suntech Power,Mono-c-Si,0,290.0,265.9,1.6268799999999999,1.64,0.992,60.0,9.55,39.8,9.15,31.7,0.005004200000000001,-0.1311012,44.4,1.6041919376508482,9.550289168701624,1.6032591410264904e-10,0.3277594258746423,10824.521834065914,3.243708268301349,-0.4267,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP295-24/Vd,Suntech Power,Multi-c-Si,0,295.0,267.2,1.9403519999999999,1.956,0.992,72.0,8.53,44.9,8.02,36.8,0.00739551,-0.1921271,45.7,1.9400743094571202,8.534246691384787,7.521155372584544e-10,0.2998108792400342,602.2071791200171,-9.650067889517533,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP295-24/Vdx,Suntech Power,Multi-c-Si,0,295.0,267.2,1.9403519999999999,1.956,0.992,72.0,8.53,44.9,8.02,36.8,0.00739551,-0.1921271,45.7,1.9400743094571202,8.534246691384787,7.521155372584544e-10,0.2998108792400342,602.2071791200171,-9.650067889517533,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP295-24/Ve,Suntech Power,Multi-c-Si,0,295.0,267.2,1.9403519999999999,1.956,0.992,72.0,8.53,44.9,8.02,36.8,0.00739551,-0.1921271,45.7,1.9400743094571202,8.534246691384787,7.521155372584544e-10,0.2998108792400342,602.2071791200171,-9.650067889517533,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP295-24/Ver,Suntech Power,Multi-c-Si,0,295.0,267.2,1.9403519999999999,1.956,0.992,72.0,8.53,44.9,8.02,36.8,0.00739551,-0.1921271,45.7,1.9400743094571202,8.534246691384787,7.521155372584544e-10,0.2998108792400342,602.2071791200171,-9.650067889517533,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP300-24/Vd,Suntech Power,Multi-c-Si,0,300.0,271.9,1.9403519999999999,1.956,0.992,72.0,8.67,45.0,8.14,36.9,0.00751689,-0.192555,45.7,1.9465985704967397,8.675174002594213,7.833718403112398e-10,0.2927070211132223,490.4850466479763,-9.466441726232667,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP300-24/Vdx,Suntech Power,Multi-c-Si,0,300.0,271.9,1.9403519999999999,1.956,0.992,72.0,8.67,45.0,8.14,36.9,0.00751689,-0.192555,45.7,1.9465985704967397,8.675174002594213,7.833718403112398e-10,0.2927070211132223,490.4850466479763,-9.466441726232667,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP300-24/Ve,Suntech Power,Multi-c-Si,0,300.0,271.9,1.9403519999999999,1.956,0.992,72.0,8.67,45.0,8.14,36.9,0.00751689,-0.192555,45.7,1.9465985704967397,8.675174002594213,7.833718403112398e-10,0.2927070211132223,490.4850466479763,-9.466441726232667,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP300-24/Ver,Suntech Power,Multi-c-Si,0,300.0,271.9,1.9403519999999999,1.956,0.992,72.0,8.67,45.0,8.14,36.9,0.00751689,-0.192555,45.7,1.9465985704967397,8.675174002594213,7.833718403112398e-10,0.2927070211132223,490.4850466479763,-9.466441726232667,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP305-24/Vd,Suntech Power,Multi-c-Si,0,305.0,276.5,1.9403519999999999,1.956,0.992,72.0,8.79,45.1,8.25,37.0,0.007620929999999999,-0.1929829,45.7,1.9518856556225872,8.795421031545157,8.029552561736115e-10,0.28669608294476606,464.86716277064914,-9.384789962736894,-0.4339,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suntech Power STP305-24/Vdx,Suntech Power,Multi-c-Si,0,305.0,276.5,1.9403519999999999,1.956,0.992,72.0,8.79,45.1,8.25,37.0,0.007620929999999999,-0.1929829,45.7,1.9518856556225872,8.795421031545157,8.029552561736115e-10,0.28669608294476606,464.86716277064914,-9.384789962736894,-0.4339,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suntech Power STP305-24/Ve,Suntech Power,Multi-c-Si,0,305.0,276.5,1.9403519999999999,1.956,0.992,72.0,8.79,45.1,8.25,37.0,0.007620929999999999,-0.1929829,45.7,1.9518856556225872,8.795421031545157,8.029552561736115e-10,0.28669608294476606,464.86716277064914,-9.384789962736894,-0.4339,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suntech Power STP305-24/Vem,Suntech Power,Multi-c-Si,0,305.0,278.8,1.9403519999999999,1.956,0.992,72.0,8.89,44.7,8.43,36.2,0.00518287,-0.14777820000000003,44.2,1.8218532649183161,8.890003515397632,1.9646563553326069e-10,0.37029724226733807,936700.4392286951,5.099233729617579,-0.4294,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP305-24/Ver,Suntech Power,Multi-c-Si,0,305.0,276.5,1.9403519999999999,1.956,0.992,72.0,8.79,45.1,8.25,37.0,0.007620929999999999,-0.1929829,45.7,1.9518856556225872,8.795421031545157,8.029552561736115e-10,0.28669608294476606,464.86716277064914,-9.384789962736894,-0.4339,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suntech Power STP310-24/Vd,Suntech Power,Multi-c-Si,0,310.0,281.2,1.9403519999999999,1.956,0.992,72.0,8.91,45.2,8.36,37.1,0.007724969999999999,-0.1934108,45.7,1.9571654800757234,8.915663085282326,8.227624256276928e-10,0.2808464984096179,441.8692417327192,-9.3040899804876,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP310-24/Vdx,Suntech Power,Multi-c-Si,0,310.0,281.2,1.92614,1.93,0.998,72.0,8.91,45.2,8.36,37.1,0.007724969999999999,-0.1934108,45.7,1.9571654800757234,8.915663085282326,8.227624256276928e-10,0.2808464984096179,441.8692417327192,-9.3040899804876,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP310-24/Ve,Suntech Power,Multi-c-Si,0,310.0,281.2,1.9403519999999999,1.956,0.992,72.0,8.91,45.2,8.36,37.1,0.007724969999999999,-0.1934108,45.7,1.9571654800757234,8.915663085282326,8.227624256276928e-10,0.2808464984096179,441.8692417327192,-9.3040899804876,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP310-24/Vem,Suntech Power,Multi-c-Si,0,310.0,283.5,1.9403519999999999,1.956,0.992,72.0,8.96,44.9,8.5,36.5,0.0052236800000000005,-0.1484394,44.2,1.833612811098937,8.960003452515743,2.0780705022223328e-10,0.34998480589820424,908531.4534706641,5.50947025206716,-0.4294,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP310-24/Ver,Suntech Power,Multi-c-Si,0,310.0,281.2,1.9403519999999999,1.956,0.992,72.0,8.91,45.2,8.36,37.1,0.007724969999999999,-0.1934108,45.7,1.9571654800757234,8.915663085282326,8.227624256276928e-10,0.2808464984096179,441.8692417327192,-9.3040899804876,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP310-VRM-1,Suntech Power,Multi-c-Si,0,310.0,281.2,1.9403519999999999,1.956,0.992,72.0,8.91,45.2,8.36,37.1,0.007724969999999999,-0.1934108,45.7,1.9571654800757234,8.915663085282326,8.227624256276928e-10,0.2808464984096179,441.8692417327192,-9.3040899804876,-0.4339,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP315-24/Vd,Suntech Power,Multi-c-Si,0,315.0,285.8,1.9403519999999999,1.956,0.992,72.0,8.96,45.5,8.61,36.6,0.007768320000000001,-0.19469450000000002,45.7,1.9554872659637894,8.960227959311242,7.031154939515205e-10,0.2952739932121367,11605.923592010087,-10.51940038378563,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP315-24/Vdx,Suntech Power,Multi-c-Si,0,315.0,285.8,1.9403519999999999,1.956,0.992,72.0,8.96,45.5,8.61,36.6,0.007768320000000001,-0.19469450000000002,45.7,1.9554872659637894,8.960227959311242,7.031154939515205e-10,0.2952739932121367,11605.923592010087,-10.51940038378563,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP315-24/Ve,Suntech Power,Multi-c-Si,0,315.0,285.8,1.9403519999999999,1.956,0.992,72.0,8.96,45.5,8.61,36.6,0.007768320000000001,-0.19469450000000002,45.7,1.9554872659637894,8.960227959311242,7.031154939515205e-10,0.2952739932121367,11605.923592010087,-10.51940038378563,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP315-24/Vem,Suntech Power,Multi-c-Si,0,315.0,288.2,1.9403519999999999,1.956,0.992,72.0,9.02,45.1,8.56,36.8,0.00525866,-0.1491006,44.2,1.8453206580800565,9.020003374308699,2.1926112857933867e-10,0.33039921292653734,883434.6150514263,5.910227703746618,-0.4294,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP315-24/Ver,Suntech Power,Multi-c-Si,0,315.0,285.8,1.9403519999999999,1.956,0.992,72.0,8.96,45.5,8.61,36.6,0.007768320000000001,-0.19469450000000002,45.7,1.9554872659637894,8.960227959311242,7.031154939515205e-10,0.2952739932121367,11605.923592010087,-10.51940038378563,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP320-24/Vd,Suntech Power,Multi-c-Si,0,320.0,290.5,1.9403519999999999,1.956,0.992,72.0,9.07,45.6,8.72,36.7,0.00786369,-0.1951224,45.7,1.9608544471213927,9.070224839086722,7.208386410989765e-10,0.28679147072565847,11569.259239260744,-10.42697384005845,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP320-24/Vdx,Suntech Power,Multi-c-Si,0,320.0,290.5,1.9403519999999999,1.956,0.992,72.0,9.07,45.6,8.72,36.7,0.00786369,-0.1951224,45.7,1.9608544471213927,9.070224839086722,7.208386410989765e-10,0.28679147072565847,11569.259239260744,-10.42697384005845,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP320-24/Ve,Suntech Power,Multi-c-Si,0,320.0,290.5,1.9403519999999999,1.956,0.992,72.0,9.07,45.6,8.72,36.7,0.00786369,-0.1951224,45.7,1.9608544471213927,9.070224839086722,7.208386410989765e-10,0.28679147072565847,11569.259239260744,-10.42697384005845,-0.4339,N,2025.7.3,6/23/2025,2.0,first_pass +Suntech Power STP320-24/Vem,Suntech Power,Multi-c-Si,0,320.0,292.9,1.9403519999999999,1.956,0.992,72.0,9.14,45.6,8.63,37.1,0.00532862,-0.15075360000000002,44.2,1.866644973220979,9.143410088308103,2.235817820183575e-10,0.34411084194611347,922.3145317348587,5.979637548106064,-0.4294,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP325-24/Vem,Suntech Power,Multi-c-Si,0,325.0,297.6,1.9403519999999999,1.956,0.992,72.0,9.26,45.9,8.72,37.3,0.00539858,-0.1517454,44.2,1.8802783058016208,9.265623074224228,2.2983481688839961e-10,0.34761113164214497,572.4412300534285,6.113324446817229,-0.4294,N,2025.7.3,6/23/2025,4.0,first_pass +Suntech Power STP330-24/Vem,Suntech Power,Multi-c-Si,0,330.0,302.3,1.9403519999999999,1.956,0.992,72.0,9.38,46.2,8.81,37.5,0.00546854,-0.15273720000000002,44.2,1.8938914492347816,9.387911522493104,2.3611809129097507e-10,0.3510500667335418,416.20940719098866,6.243070035290671,-0.4294,N,2025.7.3,6/23/2025,4.0,first_pass +SunTegra STS-110M-B4U,SunTegra,Mono-c-Si,0,110.0,95.3,0.66,,,24.0,9.41,15.46,8.66,12.72,0.0035758,-0.044988600000000004,57.31,0.6131456366533994,9.433877368207165,1.0140584202212824e-10,0.10119651073461694,39.881251654951896,13.17951164200265,-0.404,Y,2025.7.3,6/23/2025,4.0,first_pass +SunTegra STS-114M-B4U,SunTegra,Mono-c-Si,0,114.0,98.9,0.66,,,24.0,9.68,15.52,8.92,12.78,0.0036783999999999996,-0.0451632,57.31,0.6153845889313376,9.703333032376692,1.0386700005194131e-10,0.09742247986109999,40.41694317662573,13.135333502404709,-0.404,Y,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-385,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,385.0,361.1,1.94,,,108.0,13.25,36.6,12.55,30.7,0.000795,-0.090036,42.6,1.2983705100531653,13.25884326025604,7.490231973880137e-12,0.14367337851020812,215.2681494739451,5.940831293748643,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-390,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,390.0,365.9,1.94,,,108.0,13.34,36.8,12.62,30.9,0.0008003999999999999,-0.090528,42.6,1.337302678851063,13.348679034263041,1.4746281667431566e-11,0.13505818076847034,207.58947201915635,11.85012299755553,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-395,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,395.0,370.8,1.94,,,108.0,13.43,37.0,12.7,31.1,0.0008058000000000001,-0.09102,42.6,1.3455152554568162,13.438918638826113,1.512674786972767e-11,0.1319636037348725,198.71543648950993,12.02195596235457,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-400,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,400.0,375.6,1.94,,,108.0,13.54,37.2,12.8,31.3,0.0008124,-0.09151200000000001,42.6,1.3536729776749064,13.549088642757702,1.552003852275411e-11,0.12872433877196998,191.76983861634346,12.18254436811979,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-405,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,405.0,380.4,1.94,,,108.0,13.66,37.4,12.89,31.4,0.0008196,-0.092004,42.6,1.3151818336204706,13.672740127489876,5.9965562563165114e-12,0.1421703861732495,152.4354822789593,3.8073790424706537,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-410,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,410.0,385.2,1.94,,,108.0,13.77,37.6,12.98,31.6,0.0008261999999999999,-0.092496,42.6,1.3081066708268054,13.784182891455083,4.440075428293067e-12,0.14161887110732865,137.49607147625522,1.2371522478817014,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9609MHVC-U-415,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,415.0,390.0,1.94,,,108.0,13.87,37.8,13.06,31.8,0.0008322,-0.092988,42.6,1.37805212144007,13.882433609442359,1.6648767806413647e-11,0.1277790026146331,142.54066774346998,12.621641140622218,-0.364,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-520,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,520.0,488.4,2.56,,,144.0,13.63,48.9,12.66,41.1,0.0044979,-0.128607,42.9,1.8272270948233127,13.651570119753528,3.1433028521771324e-11,0.1641036462134381,103.69588719631838,10.72096494478468,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-525,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,525.0,493.2,2.56,,,144.0,13.69,49.0,12.74,41.2,0.0045177,-0.12887,42.9,1.829558215206752,13.710104314437299,3.0997549514390804e-11,0.16253825044586437,110.68015590207763,10.54852765297722,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-530,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,530.0,498.0,2.56,,,144.0,13.75,49.2,12.81,41.4,0.004537500000000001,-0.129396,42.9,1.8367252235458484,13.769070805122137,3.103553837629623e-11,0.1597816590011887,115.20215329433816,10.515684467896653,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-535,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,535.0,502.8,2.56,,,144.0,13.81,49.3,12.88,41.5,0.0045573,-0.129659,42.9,1.8398016973571174,13.828213691884057,3.091318562618518e-11,0.1581463410814141,119.90984544370947,10.436721880008745,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-540,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,540.0,507.7,2.56,,,144.0,13.87,49.5,12.96,41.7,0.0045771,-0.130185,42.9,1.846257563729664,13.886681374046324,3.066156144394822e-11,0.15554982885933327,129.33443794113685,10.316982433374067,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-545,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,545.0,512.5,2.56,,,144.0,13.93,49.6,13.03,41.8,0.0045969,-0.130448,42.9,1.8493501705931197,13.94586133405809,3.054847813301085e-11,0.1539512969419173,135.20562450389266,10.240837585067815,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-550,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,550.0,517.3,2.56,,,144.0,13.99,49.8,13.1,42.0,0.0046167000000000005,-0.130974,42.9,1.8565316943866284,14.00493289545982,3.0594248275049125e-11,0.15129820793739915,141.7449110248122,10.211309836903466,-0.354,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Akcome Optronics Science & Technology Co Ltd SK9612MHVC-T-U-555,Suzhou Akcome Optronics Science & Technology Co Ltd,Mono-c-Si,0,555.0,522.1,2.56,,,144.0,14.05,49.9,13.18,42.1,0.004636500000000001,-0.131237,42.9,1.8589307065875829,14.063614681295105,3.0205081150821284e-11,0.1498426496506215,154.63375113505396,10.051112493185274,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-220,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,220.0,198.3,1.6236,1.64,0.99,60.0,8.33,36.5,7.61,28.9,0.00557277,-0.13877299999999998,46.1,1.5278901307719406,8.364240100326752,3.375172196247376e-10,0.4146920187408456,100.88711118629193,-4.128165034100529,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-220,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,220.0,197.7,1.6236,1.64,0.99,60.0,8.32,36.4,7.59,29.0,0.006805760000000001,-0.14811159999999998,45.7,1.5893667650289505,8.350571141445082,9.040786588959278e-10,0.3701754343745372,100.74403537877517,-3.188103796186848,-0.4544,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-225,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,225.0,202.9,1.6236,1.64,0.99,60.0,8.39,36.6,7.68,29.3,0.0056129100000000005,-0.1391532,46.1,1.5408478692219598,8.41919874054683,3.8986913889824e-10,0.36302355696960664,104.31161885799726,-3.0599660045431363,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-225,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,225.0,202.3,1.6236,1.64,0.99,60.0,8.4,36.6,7.71,29.2,0.0068712,-0.1489254,45.7,1.593827364662144,8.425014964243013,8.646442414908403e-10,0.3627292373492839,121.80413976394796,-3.6285952072036975,-0.4544,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-230,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,230.0,207.5,1.6236,1.64,0.99,60.0,8.45,36.8,7.8,29.5,0.00565305,-0.1399136,46.1,1.5432627547159676,8.471685736537642,3.6155669442008285e-10,0.3567333319745325,139.00366965849847,-3.7277579365762747,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-230,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,230.0,206.9,1.6236,1.64,0.99,60.0,8.52,36.7,7.83,29.4,0.00696936,-0.1493323,45.7,1.60119806493621,8.543250670646003,9.166867201572284e-10,0.34027064145975244,124.68915387062026,-3.2820433311670274,-0.4544,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-235,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,235.0,212.2,1.6236,1.64,0.99,60.0,8.54,36.9,7.94,29.6,0.0057132599999999995,-0.1402938,46.1,1.5419363732400246,8.555443165000769,3.383856890363135e-10,0.3512660997237896,194.24858073501366,-4.344285492566839,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-235,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,235.0,211.5,1.6236,1.64,0.99,60.0,8.59,36.8,7.97,29.5,0.00702662,-0.1497392,45.7,1.59744716175332,8.605151192964676,8.320835812053487e-10,0.3361706387013002,190.5926777025916,-4.129417646529346,-0.4544,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-240,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,240.0,216.8,1.6236,1.64,0.99,60.0,8.62,37.0,8.06,29.8,0.00576678,-0.140674,46.1,1.5450689726587468,8.630277254895356,3.381904193314199e-10,0.33153655006553717,278.07479667540247,-4.435825901815969,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-240,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,240.0,216.2,1.6236,1.64,0.99,60.0,8.62,36.9,8.08,29.7,0.00705116,-0.1501461,45.7,1.5965970370649196,8.626335548897503,7.838969502347246e-10,0.3188808252139434,433.8616742405596,-4.646105163843032,-0.4544,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-245,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,245.0,221.4,1.6236,1.64,0.99,60.0,8.69,37.2,8.17,30.0,0.0058136099999999994,-0.14143440000000002,46.1,1.5500262806205096,8.695681941878933,3.2558313537387497e-10,0.3252661337543229,497.4643534405329,-4.806888874486456,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-245,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,245.0,220.8,1.6236,1.64,0.99,60.0,8.65,37.1,8.14,30.1,0.007075700000000001,-0.15095989999999998,45.7,1.6096435624138998,8.653335410885544,8.409769575105438e-10,0.2848459660693392,738.7155408705319,-4.134447644942611,-0.4544,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TAC208/240,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,250.0,226.1,1.6236,1.64,0.99,60.0,8.78,37.3,8.31,30.1,0.005873819999999999,-0.14181459999999999,46.1,1.549230680106542,8.780078444767897,3.070227459500111e-10,0.3203420853203747,35855.28505480666,-5.356153094694178,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660AM225,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,250.0,226.1,1.6236,1.64,0.99,60.0,8.78,37.7,8.35,30.1,0.005873819999999999,-0.1433354,46.1,1.56123764116093,8.780003041133218,2.8599792924024834e-10,0.34616857996632505,999990.1413307728,-5.897598720029959,-0.4341,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660AM240,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,250.0,226.1,1.6236,1.64,0.99,60.0,8.78,37.7,8.35,30.1,0.005873819999999999,-0.1433354,46.1,1.56123764116093,8.780003041133218,2.8599792924024834e-10,0.34616857996632505,999990.1413307728,-5.897598720029959,-0.4341,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-250,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,250.0,226.1,1.6236,1.64,0.99,60.0,8.78,37.3,8.31,30.1,0.005873819999999999,-0.14181459999999999,46.1,1.549230680106542,8.780078444767897,3.070227459500111e-10,0.3203420853203747,35855.28505480666,-5.356153094694178,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-250,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,250.0,225.4,1.6236,1.64,0.99,60.0,8.69,37.3,8.25,30.3,0.007108419999999999,-0.15177369999999998,45.7,1.6148283729063513,8.725871498611097,8.114958495686889e-10,0.2790936223899786,999999.9788245852,-4.489058275453774,-0.4544,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-255,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,255.0,232.8,1.6236,1.64,0.99,60.0,8.81,37.5,8.44,30.2,0.007514930000000001,-0.1549125,44.2,1.605297281056991,8.810178761966979,6.304529227487387e-10,0.2608162668186746,12854.047644253686,-7.960974176772493,-0.4351,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-255,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,255.0,230.1,1.6236,1.64,0.99,60.0,8.73,37.5,8.39,30.4,0.00714114,-0.1525875,45.7,1.6367274457937977,8.730168215917814,9.783247840764414e-10,0.21157769965809362,10980.505134966668,-3.030715135140483,-0.4544,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-260,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,260.0,237.5,1.6236,1.64,0.99,60.0,8.83,37.7,8.55,30.4,0.0075319900000000006,-0.15573870000000004,44.2,1.6245253123868528,8.830156868233287,7.365877138695029e-10,0.19627510554706712,11048.283186803134,-6.805938210515593,-0.4351,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-260,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,260.0,235.2,1.6236,1.64,0.99,72.0,8.85,37.7,8.5,30.6,0.0058941,-0.12836850000000002,45.3,1.6029486592125868,8.850180619448425,5.401871938182062e-10,0.22469795968158218,11009.841644812272,10.654420701468068,-0.4546,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-265,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,265.0,236.6,1.6236,1.64,0.99,60.0,8.83,38.1,8.59,30.9,0.00458277,-0.12854939999999998,47.1,1.635689361452769,8.830001339981825,6.760321412499437e-10,0.15165220900001045,999990.7652272753,13.914587961265763,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P(H)-265,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,265.0,240.8,1.6236,1.64,0.99,60.0,9.04,38.2,8.56,31.0,0.0052793599999999994,-0.13645040000000003,43.2,1.6582272198261367,9.056055375468326,8.958747224366392e-10,0.27845469617004165,999999.8434643089,9.743978492998568,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-265,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,265.0,240.8,1.6236,1.64,0.99,60.0,9.04,38.2,8.56,31.0,0.0052793599999999994,-0.13645040000000003,43.2,1.6582272198261367,9.056055375468326,8.958747224366392e-10,0.27845469617004165,999999.8434643089,9.743978492998568,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-270,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,270.0,241.2,1.6236,1.64,0.99,60.0,8.89,38.2,8.71,31.0,0.004613910000000001,-0.12888680000000002,47.1,1.6461223148647173,8.890000796886625,7.424028205890619e-10,0.08958650246280676,999999.9023147329,14.718636097930279,-0.4718,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P(H)-270,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,270.0,245.5,1.6236,1.64,0.99,60.0,9.09,38.5,8.63,31.3,0.0053085599999999995,-0.137522,43.2,1.672670685076183,9.12841880456175,9.208769156924201e-10,0.27071353264489817,999999.9757892308,9.919940939720151,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-270,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,270.0,245.5,1.6236,1.64,0.99,60.0,9.09,38.5,8.63,31.3,0.0053085599999999995,-0.137522,43.2,1.672670685076183,9.12841880456175,9.208769156924201e-10,0.27071353264489817,999999.9757892308,9.919940939720151,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M(H)-275,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,275.0,251.2,1.6236,1.64,0.99,60.0,9.3,38.7,8.73,31.5,0.004603500000000001,-0.12651030000000002,43.3,1.6311401918051727,9.30693936278053,4.5700406411974685e-10,0.27482211210864815,368.3113798310416,13.520206421863314,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-275,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,275.0,251.2,1.6236,1.64,0.99,60.0,9.3,38.7,8.73,31.5,0.004603500000000001,-0.12651030000000002,43.3,1.6311401918051727,9.30693936278053,4.5700406411974685e-10,0.27482211210864815,368.3113798310416,13.520206421863314,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P(H)-275,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,275.0,250.1,1.6236,1.64,0.99,60.0,9.17,38.7,8.69,31.7,0.0053552800000000005,-0.1382364,43.2,1.6883326572973338,9.185180103543518,1.019008353521756e-09,0.23811771780909152,999999.7515535016,10.76966334647198,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-275,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,275.0,250.1,1.6236,1.64,0.99,60.0,9.17,38.7,8.69,31.7,0.0053552800000000005,-0.1382364,43.2,1.6883326572973338,9.185180103543518,1.019008353521756e-09,0.23811771780909152,999999.7515535016,10.76966334647198,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M(H)-280,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,280.0,255.9,1.6236,1.64,0.99,60.0,9.35,38.9,8.81,31.8,0.00462825,-0.1271641,43.3,1.6403475379452575,9.354058311906478,4.665148786417835e-10,0.25676426443142625,591.5629070219222,13.646827526058749,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-280,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,280.0,255.9,1.6236,1.64,0.99,60.0,9.35,38.9,8.81,31.8,0.00462825,-0.1271641,43.3,1.6403475379452575,9.354058311906478,4.665148786417835e-10,0.25676426443142625,591.5629070219222,13.646827526058749,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P(H)-280,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,280.0,254.8,1.6236,1.64,0.99,60.0,9.25,39.0,8.76,32.0,0.005402,-0.13930800000000002,43.2,1.7030316708561781,9.257673896123103,1.049566228739542e-09,0.230762691455692,999999.9504024014,10.964349455876667,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-280,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,280.0,254.8,1.6236,1.64,0.99,60.0,9.25,39.0,8.76,32.0,0.005402,-0.13930800000000002,43.2,1.7030316708561781,9.257673896123103,1.049566228739542e-09,0.230762691455692,999999.9504024014,10.964349455876667,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-280,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,280.0,251.8,1.9404,1.96,0.99,72.0,8.58,44.0,7.94,35.3,0.009703980000000001,-0.19866,46.6,1.9573494253007786,8.595824114271133,1.448397849966137e-09,0.38686884997035526,209.76441574638292,-10.02928035215855,-0.4389,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M(H)-285,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,285.0,260.6,1.6236,1.64,0.99,60.0,9.41,39.1,8.88,32.1,0.00465795,-0.1278179,43.3,1.6514565380395296,9.413025554505763,4.885445474669431e-10,0.23851337390724617,741.8183000204315,14.007783248769348,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-285,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,285.0,260.6,1.6236,1.64,0.99,60.0,9.41,39.1,8.88,32.1,0.00465795,-0.1278179,43.3,1.6514565380395296,9.413025554505763,4.885445474669431e-10,0.23851337390724617,741.8183000204315,14.007783248769348,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P(H)-285,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,285.0,259.5,1.6236,1.64,0.99,60.0,9.3,39.3,8.83,32.3,0.005431200000000001,-0.1403796,43.2,1.7174665448294693,9.330110795093415,1.0767709657365637e-09,0.2235884652963333,999999.9807997224,11.12638742152167,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660P-285,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,285.0,259.5,1.6236,1.64,0.99,60.0,9.3,39.3,8.83,32.3,0.005431200000000001,-0.1403796,43.2,1.7174665448294693,9.330110795093415,1.0767709657365637e-09,0.2235884652963333,999999.9807997224,11.12638742152167,-0.4877,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-285,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,285.0,257.0,1.9404,1.96,0.99,72.0,8.59,44.5,7.99,35.7,0.007138289999999999,-0.1910385,46.2,1.9105049192752994,8.603514057208102,6.459685912770699e-10,0.4075328660416365,259.04196661761875,-11.044897657724384,-0.4384,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-285,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,285.0,256.4,1.9404,1.96,0.99,72.0,8.67,44.1,8.05,35.4,0.00980577,-0.1991115,46.6,1.958630481635575,8.683171085944636,1.4169005872284671e-09,0.3811864776162917,250.9199576216851,-10.274532046373862,-0.4389,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M(H)-290,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,290.0,265.3,1.6236,1.64,0.99,60.0,9.47,39.3,8.96,32.4,0.004687650000000001,-0.1284717,43.3,1.661556975345966,9.4714084782155,5.047103918474407e-10,0.22073397978438009,1484.1213254729598,14.240296832297753,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-290,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,290.0,265.3,1.6236,1.64,0.99,60.0,9.47,39.3,8.96,32.4,0.004687650000000001,-0.1284717,43.3,1.661556975345966,9.4714084782155,5.047103918474407e-10,0.22073397978438009,1484.1213254729598,14.240296832297753,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-290,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,290.0,261.6,1.9404,1.96,0.99,72.0,8.65,44.7,8.11,35.8,0.00718815,-0.19189710000000004,46.2,1.9084216931397833,8.656700659094621,5.766275253421731e-10,0.4159934186141775,537.0135607974315,-11.930826912317878,-0.4384,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-290,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,290.0,261.1,1.9404,1.96,0.99,72.0,8.75,44.3,8.15,35.6,0.009896250000000002,-0.2000145,46.6,1.9652636761592792,8.760574074211808,1.398706276830334e-09,0.37398227693868025,309.4688677944503,-10.442959973578697,-0.4389,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M(H)-295,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,295.0,270.0,1.6236,1.64,0.99,60.0,9.52,39.5,9.05,32.6,0.0047124,-0.1291255,43.3,1.668803204834886,9.542854065351383,5.012737011161835e-10,0.21598534142365622,999999.9811791572,14.098847898785136,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-295,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,295.0,270.0,1.6236,1.64,0.99,60.0,9.52,39.5,9.05,32.6,0.0047124,-0.1291255,43.3,1.668803204834886,9.542854065351383,5.012737011161835e-10,0.21598534142365622,999999.9811791572,14.098847898785136,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-295,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,295.0,266.3,1.9404,1.96,0.99,72.0,8.7,44.9,8.22,35.9,0.007229699999999999,-0.1927557,46.2,1.907147096482164,8.703711119612883,5.189183917975883e-10,0.4243512380063592,999999.9836404668,-12.74294471335089,-0.4384,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-295,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,295.0,265.7,1.9404,1.96,0.99,72.0,8.82,44.5,8.24,35.8,0.00997542,-0.2009175,46.6,1.9720486529458665,8.828113229913207,1.3814557683978085e-09,0.3673350507967993,399.33509628375793,-10.598171832151728,-0.4389,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M(H)-300,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,300.0,274.8,1.6236,1.64,0.99,60.0,9.58,39.7,9.12,32.9,0.0047421,-0.12977930000000001,43.3,1.6807464363548306,9.613027574254174,5.30424996690017e-10,0.198196457616022,999999.9813845907,14.553747397802908,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP660M-300,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,300.0,274.8,1.6236,1.64,0.99,60.0,9.58,39.7,9.12,32.9,0.0047421,-0.12977930000000001,43.3,1.6807464363548306,9.613027574254174,5.30424996690017e-10,0.198196457616022,999999.9813845907,14.553747397802908,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-300,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,300.0,270.9,1.9404,1.96,0.99,72.0,8.75,45.2,8.32,36.1,0.00727125,-0.1940436,46.2,1.9256416856224476,8.75000347117128,5.596855060405762e-10,0.39637549574832587,999992.6154312345,-12.243689266645497,-0.4384,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-300,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,300.0,270.3,1.9404,1.96,0.99,72.0,8.88,45.0,8.33,36.1,0.0040404,-0.13356,46.6,1.8215942925713058,8.889301813662511,1.6396578997552255e-10,0.4242746036759939,405.034875596173,15.670109098359683,-0.4392,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-305,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,305.0,275.5,1.9404,1.96,0.99,72.0,8.79,45.5,8.36,36.5,0.0073044899999999986,-0.19533150000000002,46.2,1.9430591012581777,8.790003300478814,5.946348530158395e-10,0.37517937278660685,999999.9462133513,-11.843556110963693,-0.4384,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-305,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,305.0,276.7,1.9404,1.96,0.99,72.0,8.99,45.0,8.43,36.2,0.005465920000000001,-0.147105,45.7,1.8419830557314683,8.999173765231903,2.1814327593333585e-10,0.4009026921277708,392.8720250505234,7.1084574906033025,-0.4307,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-310,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,310.0,280.2,1.9404,1.96,0.99,72.0,8.83,45.8,8.4,36.9,0.00733773,-0.1966194,46.2,1.9604747447932098,8.830003129816543,6.31111752843528e-10,0.3541716707719871,999999.9462526991,-11.448800934502541,-0.4384,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-310,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,310.0,281.4,1.9404,1.96,0.99,72.0,9.09,45.2,8.52,36.4,0.00552672,-0.14775880000000002,45.7,1.851728419922101,9.099642277786687,2.2500568620867263e-10,0.3928351768697231,370.33491820809354,7.282800924193313,-0.4307,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-315,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,315.0,285.9,1.9404,1.96,0.99,72.0,8.87,46.0,8.49,37.1,0.005676799999999999,-0.15290399999999998,45.2,1.9165959563058133,8.870002991436383,3.345564464712978e-10,0.3371083038212499,999990.6474121123,9.069247566995879,-0.4432,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-315,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,315.0,286.2,1.9404,1.96,0.99,72.0,9.11,45.2,8.56,36.8,0.00532024,-0.16145440000000003,43.2,1.9723793238787086,9.114527796890266,1.0087113424608506e-09,0.3101993874859935,624.1265888224558,10.774010554771992,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-315,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,315.0,286.2,1.9404,1.96,0.99,72.0,9.11,45.2,8.56,36.8,0.00532024,-0.16145440000000003,43.2,1.9723793238787086,9.114527796890266,1.0087113424608506e-09,0.3101993874859935,624.1265888224558,10.774010554771992,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-320,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,320.0,290.6,1.9404,1.96,0.99,72.0,8.9,46.2,8.58,37.3,0.0056960000000000005,-0.1535688,45.2,1.9330919712237347,8.900182866115077,3.713648007411969e-10,0.2862482026302683,13931.62264552455,9.965016839785719,-0.4432,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-320,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,320.0,290.8,1.9404,1.96,0.99,72.0,9.16,45.5,8.63,37.1,0.0053494400000000004,-0.162526,43.2,1.984331959412886,9.162652893816295,1.0040252546949781e-09,0.30328985823850196,1047.2105203960023,10.673807519007413,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-320,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,320.0,290.8,1.9404,1.96,0.99,72.0,9.16,45.5,8.63,37.1,0.0053494400000000004,-0.162526,43.2,1.984331959412886,9.162652893816295,1.0040252546949781e-09,0.30328985823850196,1047.2105203960023,10.673807519007413,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-325,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,325.0,296.8,1.9404,1.96,0.99,72.0,9.18,46.3,8.67,37.5,0.0045441,-0.1513547,43.3,1.939734022564365,9.181950511082313,3.938698146834188e-10,0.3590507211322552,1689.8589424883999,12.257805796971127,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-325,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,325.0,296.8,1.9404,1.96,0.99,72.0,9.18,46.3,8.67,37.5,0.0045441,-0.1513547,43.3,1.939734022564365,9.181950511082313,3.938698146834188e-10,0.3590507211322552,1689.8589424883999,12.257805796971127,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-325,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,325.0,295.5,1.9404,1.96,0.99,72.0,9.22,45.7,8.7,37.4,0.0053844800000000005,-0.1632404,43.2,1.9956783415520971,9.221701953055899,1.043019548350295e-09,0.28423083988358316,1539.7679126519502,10.953587442465322,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-325,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,325.0,295.5,1.9404,1.96,0.99,72.0,9.22,45.7,8.7,37.4,0.0053844800000000005,-0.1632404,43.2,1.9956783415520971,9.221701953055899,1.043019548350295e-09,0.28423083988358316,1539.7679126519502,10.953587442465322,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M(H)-325,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,325.0,299.5,1.687,,,60.0,10.06,40.3,9.61,33.8,0.00278662,-0.11541919999999999,45.5,1.54772343392719,10.060002567065478,4.9468650908261225e-11,0.1808750070766189,708854.8517562343,7.964274301186056,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M-325,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,325.0,299.5,1.687,,,60.0,10.06,40.3,9.61,33.8,0.00278662,-0.11541919999999999,45.5,1.54772343392719,10.060002567065478,4.9468650908261225e-11,0.1808750070766189,708854.8517562343,7.964274301186056,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-330,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,330.0,301.5,1.9404,1.96,0.99,72.0,9.24,46.5,8.72,37.9,0.004573800000000001,-0.15200850000000002,43.3,1.9558870568936664,9.242820743194246,4.351834197613264e-10,0.326035067117923,1068.0042503736452,13.111309174462333,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-330,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,330.0,301.5,1.9404,1.96,0.99,72.0,9.24,46.5,8.72,37.9,0.004573800000000001,-0.15200850000000002,43.3,1.9558870568936664,9.242820743194246,4.351834197613264e-10,0.326035067117923,1068.0042503736452,13.111309174462333,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-330,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,330.0,300.2,1.9404,1.96,0.99,72.0,9.27,45.9,8.76,37.7,0.00541368,-0.1639548,43.2,2.0070868311259904,9.270894621985812,1.0826161824213531e-09,0.265764400598127,2753.83706779974,11.236862487070029,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-330,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,330.0,300.2,1.9404,1.96,0.99,72.0,9.27,45.9,8.76,37.7,0.00541368,-0.1639548,43.2,2.0070868311259904,9.270894621985812,1.0826161824213531e-09,0.265764400598127,2753.83706779974,11.236862487070029,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M(H)-330,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,330.0,304.2,1.687,,,60.0,10.12,40.5,9.66,34.1,0.00280324,-0.115992,45.5,1.5575168239091917,10.120002422833497,5.1552454603660656e-11,0.16515086156350064,689851.4309667752,8.271103089131127,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M-330,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,330.0,304.2,1.687,,,60.0,10.12,40.5,9.66,34.1,0.00280324,-0.115992,45.5,1.5575168239091917,10.120002422833497,5.1552454603660656e-11,0.16515086156350064,689851.4309667752,8.271103089131127,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-335,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,335.0,306.2,1.9404,1.96,0.99,72.0,9.3,46.7,8.77,38.2,0.004603500000000001,-0.15266230000000003,43.3,1.969107558311909,9.303455095976462,4.6358191964946705e-10,0.30684017604114605,825.9147950396858,13.635163990223546,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-335,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,335.0,306.2,1.9404,1.96,0.99,72.0,9.3,46.7,8.77,38.2,0.004603500000000001,-0.15266230000000003,43.3,1.969107558311909,9.303455095976462,4.6358191964946705e-10,0.30684017604114605,825.9147950396858,13.635163990223546,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-335,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,335.0,304.9,1.9404,1.96,0.99,72.0,9.34,46.2,8.82,38.0,0.00545456,-0.16502640000000002,43.2,2.0226499915051366,9.341386338778982,1.1202489017492682e-09,0.25817147672610685,1739.3483413307094,11.481040772886267,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-335,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,335.0,304.9,1.9404,1.96,0.99,72.0,9.34,46.2,8.82,38.0,0.00545456,-0.16502640000000002,43.2,2.0226499915051366,9.341386338778982,1.1202489017492682e-09,0.25817147672610685,1739.3483413307094,11.481040772886267,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M(H)-335,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,335.0,309.0,1.69,,,60.0,10.18,40.7,9.74,34.4,0.00281986,-0.11656480000000001,45.5,1.569564911890444,10.180002225005682,5.573941447758823e-11,0.14915021445413992,682430.2681718528,8.90081885956996,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M-335,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,335.0,309.0,1.69,,,60.0,10.18,40.7,9.74,34.4,0.00281986,-0.11656480000000001,45.5,1.569564911890444,10.180002225005682,5.573941447758823e-11,0.14915021445413992,682430.2681718528,8.90081885956996,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-340,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,340.0,310.9,1.9404,1.96,0.99,72.0,9.37,47.0,8.82,38.6,0.00463815,-0.15364300000000003,43.3,1.9882223135363506,9.37469666445087,5.032012054409571e-10,0.2856088403752642,569.799200343039,14.329950198750055,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-340,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,340.0,310.9,1.9404,1.96,0.99,72.0,9.37,47.0,8.82,38.6,0.00463815,-0.15364300000000003,43.3,1.9882223135363506,9.37469666445087,5.032012054409571e-10,0.2856088403752642,569.799200343039,14.329950198750055,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-340,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,340.0,309.6,1.9404,1.96,0.99,72.0,9.4,46.4,8.89,38.3,0.0054896,-0.1657408,43.2,2.033959124356235,9.400626871167876,1.1618552590330547e-09,0.2399122660920528,3597.5235435829613,11.749317240902505,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-340,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,340.0,309.6,1.9404,1.96,0.99,72.0,9.4,46.4,8.89,38.3,0.0054896,-0.1657408,43.2,2.033959124356235,9.400626871167876,1.1618552590330547e-09,0.2399122660920528,3597.5235435829613,11.749317240902505,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M(H)-340,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,340.0,313.7,1.69,,,60.0,10.24,40.9,9.8,34.7,0.00283648,-0.1171376,45.5,1.5801125960828026,10.240002047019907,5.873792560878563e-11,0.1336797766227203,668745.3512603871,9.30857282938126,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M-340,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,340.0,313.7,1.69,,,60.0,10.24,40.9,9.8,34.7,0.00283648,-0.1171376,45.5,1.5801125960828026,10.240002047019907,5.873792560878563e-11,0.1336797766227203,668745.3512603871,9.30857282938126,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-345,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,345.0,315.6,1.9404,1.96,0.99,72.0,9.43,47.2,8.87,38.9,0.00466785,-0.1542968,43.3,2.0014627571292327,9.435071194492679,5.351625351819449e-10,0.26686246564908306,496.23687730452474,14.84529482981972,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-345,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,345.0,315.6,1.9404,1.96,0.99,72.0,9.43,47.2,8.87,38.9,0.00466785,-0.1542968,43.3,2.0014627571292327,9.435071194492679,5.351625351819449e-10,0.26686246564908306,496.23687730452474,14.84529482981972,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P(H)-345,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,345.0,314.3,1.9404,1.96,0.99,72.0,9.46,46.6,8.95,38.6,0.005524640000000001,-0.16645520000000003,43.2,2.046518711633191,9.460562336752412,1.2198162670779127e-09,0.2216824696721912,3729.282269641433,12.134187597590122,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672P-345,Suzhou Talesun Solar Technologies Co Ltd,Multi-c-Si,0,345.0,314.3,1.9404,1.96,0.99,72.0,9.46,46.6,8.95,38.6,0.005524640000000001,-0.16645520000000003,43.2,2.046518711633191,9.460562336752412,1.2198162670779127e-09,0.2216824696721912,3729.282269641433,12.134187597590122,-0.4877,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M(H)-345,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,345.0,318.5,1.69,,,60.0,10.34,41.1,9.89,34.9,0.00286418,-0.1177104,45.5,1.5867382180633027,10.356831911222185,5.835063628016173e-11,0.12961531384138564,999999.9831360318,9.151536437305193,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M-345,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,345.0,318.5,1.69,,,60.0,10.34,41.1,9.89,34.9,0.00286418,-0.1177104,45.5,1.5867382180633027,10.356831911222185,5.835063628016173e-11,0.12961531384138564,999999.9831360318,9.151536437305193,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-350,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,350.0,320.3,1.9404,1.96,0.99,72.0,9.5,47.4,8.92,39.3,0.0047025,-0.1549506,43.3,2.0188104045928843,9.505761881998243,5.963175552166819e-10,0.2346547760779687,386.89109318480433,15.794493784098107,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-350,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,350.0,320.3,1.9404,1.96,0.99,72.0,9.5,47.4,8.92,39.3,0.0047025,-0.1549506,43.3,2.0188104045928843,9.505761881998243,5.963175552166819e-10,0.2346547760779687,386.89109318480433,15.794493784098107,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M(H)-350,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,350.0,323.2,1.69,,,60.0,10.38,41.6,9.91,35.3,0.00287526,-0.11914240000000001,45.5,1.6058247682633746,10.380098934399426,5.826111407385068e-11,0.13367003446222286,14024.40491433933,9.119005896821168,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F60M-350,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,350.0,323.2,1.69,,,60.0,10.38,41.6,9.91,35.3,0.00287526,-0.11914240000000001,45.5,1.6058247682633746,10.380098934399426,5.826111407385068e-11,0.13367003446222286,14024.40491433933,9.119005896821168,-0.3915,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-355,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,355.0,325.0,1.9404,1.96,0.99,72.0,9.56,47.6,8.97,39.6,0.004732200000000001,-0.15560440000000003,43.3,2.032067978706563,9.56585619625189,6.330963549064108e-10,0.21640940882309126,353.27954439043964,16.301260619640622,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-355,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,355.0,325.0,1.9404,1.96,0.99,72.0,9.56,47.6,8.97,39.6,0.004732200000000001,-0.15560440000000003,43.3,2.032067978706563,9.56585619625189,6.330963549064108e-10,0.21640940882309126,353.27954439043964,16.301260619640622,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-360,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,360.0,329.7,1.9404,1.96,0.99,72.0,9.62,47.8,9.01,40.0,0.0047619,-0.1562582,43.3,2.0495395794687665,9.6260334886496,7.035962517804896e-10,0.18501578733803242,294.9955209478352,17.249331814489754,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-360,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,360.0,329.7,1.9404,1.96,0.99,72.0,9.62,47.8,9.01,40.0,0.0047619,-0.1562582,43.3,2.0495395794687665,9.6260334886496,7.035962517804896e-10,0.18501578733803242,294.9955209478352,17.249331814489754,-0.4637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M(H)-360,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,360.0,334.0,1.82,,,60.0,11.15,40.7,10.5,34.3,0.0037352500000000003,-0.11973940000000001,45.5,1.5374701392539556,11.158176772725628,3.493686371787805e-11,0.1533910574312434,209.16691250174011,1.3364317194242623,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M-360,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,360.0,334.0,1.82,,,60.0,11.15,40.7,10.5,34.3,0.0037352500000000003,-0.11973940000000001,45.5,1.5374701392539556,11.158176772725628,3.493686371787805e-11,0.1533910574312434,209.16691250174011,1.3364317194242623,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-365,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,365.0,340.4,1.944,,,72.0,9.77,48.0,9.29,39.3,0.004298799999999999,-0.128736,43.9,1.7846064487820104,9.771842551876665,2.031146325749208e-11,0.34947009439324617,1853.040347004296,7.39291914984921,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-365,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,365.0,340.4,1.944,,,72.0,9.77,48.0,9.29,39.3,0.004298799999999999,-0.128736,43.9,1.7846064487820104,9.771842551876665,2.031146325749208e-11,0.34947009439324617,1853.040347004296,7.39291914984921,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M(H)-365,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,365.0,338.7,1.82,,,60.0,11.2,40.9,10.56,34.6,0.0037519999999999997,-0.1203278,45.5,1.5471458992098648,11.20695201522684,3.642978631755149e-11,0.1393131800838252,224.43961592910676,1.6383636375568638,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M-365,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,365.0,338.7,1.82,,,60.0,11.2,40.9,10.56,34.6,0.0037519999999999997,-0.1203278,45.5,1.5471458992098648,11.20695201522684,3.642978631755149e-11,0.1393131800838252,224.43961592910676,1.6383636375568638,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-370,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,370.0,345.2,1.944,,,72.0,9.83,48.3,9.35,39.6,0.0043251999999999995,-0.1295406,43.9,1.7967442599053123,9.831647998743689,2.0744191754294355e-11,0.34280584665694225,2044.7720395840402,7.52222437166774,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-370,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,370.0,345.2,1.944,,,72.0,9.83,48.3,9.35,39.6,0.0043251999999999995,-0.1295406,43.9,1.7967442599053123,9.831647998743689,2.0744191754294355e-11,0.34280584665694225,2044.7720395840402,7.52222437166774,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M(H)-370,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,370.0,343.5,1.82,,,60.0,11.26,41.1,10.61,34.9,0.0037721000000000005,-0.12091620000000002,45.5,1.5582535810450702,11.266666066137162,3.8851855628555876e-11,0.12496890852610061,211.09150316581471,2.126923860495421,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M-370,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,370.0,343.5,1.82,,,60.0,11.26,41.1,10.61,34.9,0.0037721000000000005,-0.12091620000000002,45.5,1.5582535810450702,11.266666066137162,3.8851855628555876e-11,0.12496890852610061,211.09150316581471,2.126923860495421,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-375,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,375.0,350.0,1.944,,,72.0,9.89,48.5,9.43,39.8,0.0043516,-0.130077,43.9,1.8036760287020859,9.890004528980604,2.0759613644334872e-11,0.3376283627074524,737302.047112238,7.467403642331204,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-375,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,375.0,350.0,1.944,,,72.0,9.89,48.5,9.43,39.8,0.0043516,-0.130077,43.9,1.8036760287020859,9.890004528980604,2.0759613644334872e-11,0.3376283627074524,737302.047112238,7.467403642331204,-0.3609,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M(H)-375,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,375.0,348.3,1.82,,,60.0,11.31,41.3,10.66,35.2,0.0037888500000000003,-0.1215046,45.5,1.547520883931506,11.31000346892041,2.9045174732848924e-11,0.11522602674792679,375684.8316336818,-0.33635792019653576,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L60M-375,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,375.0,348.3,1.82,,,60.0,11.31,41.3,10.66,35.2,0.0037888500000000003,-0.1215046,45.5,1.547520883931506,11.31000346892041,2.9045174732848924e-11,0.11522602674792679,375684.8316336818,-0.33635792019653576,-0.3637,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-380,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,380.0,348.3,1.98,,,72.0,10.2,48.3,9.6,39.6,0.0059261999999999995,-0.1728174,46.3,1.937740173748266,10.207633330375167,1.5086158859887403e-10,0.30055623474958726,401.61681435839404,-6.004784896923349,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-380,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,380.0,348.3,1.98,,,72.0,10.2,48.3,9.6,39.6,0.0059261999999999995,-0.1728174,46.3,1.937740173748266,10.207633330375167,1.5086158859887403e-10,0.30055623474958726,401.61681435839404,-6.004784896923349,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-385,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,385.0,353.1,1.98,,,72.0,10.28,48.5,9.68,39.8,0.00597268,-0.173533,46.3,1.9462699492240394,10.287249977192346,1.531067026294147e-10,0.29514808330048264,418.5009768100591,-5.953284088374481,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-385,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,385.0,353.1,1.98,,,72.0,10.28,48.5,9.68,39.8,0.00597268,-0.173533,46.3,1.9462699492240394,10.287249977192346,1.531067026294147e-10,0.29514808330048264,418.5009768100591,-5.953284088374481,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-385,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,385.0,353.6,2.01,,,72.0,10.2,48.5,9.68,39.8,0.0032537999999999994,-0.1559275,45.0,1.9080672366483076,10.200007222413033,9.322416933138887e-11,0.3048417673146134,429816.78648914385,0.9909221923326678,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-385,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,385.0,353.6,2.01,,,72.0,10.2,48.5,9.68,39.8,0.0032537999999999994,-0.1559275,45.0,1.9080672366483076,10.200007222413033,9.322416933138887e-11,0.3048417673146134,429816.78648914385,0.9909221923326678,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-390,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,390.0,357.8,1.98,,,72.0,10.35,48.7,9.75,40.0,0.00601335,-0.17424860000000003,46.3,1.9548634919122037,10.35691700741836,1.5533106652137414e-10,0.2901015418255525,434.0824032861721,-5.896404156858739,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-390,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,390.0,357.8,1.98,,,72.0,10.35,48.7,9.75,40.0,0.00601335,-0.17424860000000003,46.3,1.9548634919122037,10.35691700741836,1.5533106652137414e-10,0.2901015418255525,434.0824032861721,-5.896404156858739,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-390,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,390.0,358.3,2.01,,,72.0,10.28,48.7,9.75,40.0,0.00327932,-0.15657050000000003,45.0,1.9161620142967382,10.2800067622163,9.423806527131819e-11,0.29964495204681874,455507.7525361158,1.0152893381428765,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-390,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,390.0,358.3,2.01,,,72.0,10.28,48.7,9.75,40.0,0.00327932,-0.15657050000000003,45.0,1.9161620142967382,10.2800067622163,9.423806527131819e-11,0.29964495204681874,455507.7525361158,1.0152893381428765,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M(H)-390,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,390.0,358.0,2.012,,,72.0,10.35,48.7,9.75,40.0,0.0048217545,-0.14909018000000002,45.2,1.9521892636275457,10.356979966156114,1.5010890514683233e-10,0.2906838504506527,431.03044200133127,9.945044282415543,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M-390,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,390.0,358.0,2.012,,,72.0,10.35,48.7,9.75,40.0,0.0048217545,-0.14909018000000002,45.2,1.9521892636275457,10.356979966156114,1.5010890514683233e-10,0.2906838504506527,431.03044200133127,9.945044282415543,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6G72M-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,395.0,362.9,2.053,,,72.0,10.29,48.7,9.76,40.5,0.00464079,-0.16392420000000002,45.3,1.94889830319323,10.292023180803264,1.4402048864778474e-10,0.23552706854535368,1197.9028059167267,-0.3487111251148709,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,362.5,1.98,,,72.0,10.41,49.0,9.81,40.3,0.00604821,-0.175322,46.3,1.9680323800794928,10.41661067556065,1.585197326363901e-10,0.28385613281869404,446.9955274449496,-5.786720439307392,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,362.5,1.98,,,72.0,10.41,49.0,9.81,40.3,0.00604821,-0.175322,46.3,1.9680323800794928,10.41661067556065,1.585197326363901e-10,0.28385613281869404,446.9955274449496,-5.786720439307392,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,363.1,2.01,,,72.0,10.35,48.9,9.81,40.3,0.0033016499999999997,-0.1572135,45.0,1.9263776777598487,10.350006258198293,9.786292668768926e-11,0.2830528484286104,468147.646771959,1.2667057617203765,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,363.1,2.01,,,72.0,10.35,48.9,9.81,40.3,0.0033016499999999997,-0.1572135,45.0,1.9263776777598487,10.350006258198293,9.786292668768926e-11,0.2830528484286104,468147.646771959,1.2667057617203765,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M(H)-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,395.0,370.9,2.05,,,72.0,10.14,48.9,9.61,41.1,0.00452244,-0.1310031,42.44,1.8389042047774098,10.14433137974871,2.8402602623513333e-11,0.2170522881698438,508.131441425448,10.15670763915,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,395.0,370.9,2.05,,,72.0,10.14,48.9,9.61,41.1,0.00452244,-0.1310031,42.44,1.8389042047774098,10.14433137974871,2.8402602623513333e-11,0.2170522881698438,508.131441425448,10.15670763915,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M(H)-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,362.7,2.012,,,72.0,10.41,49.0,9.81,40.3,0.0048497067,-0.15000860000000002,45.2,1.965291267879367,10.41667351228233,1.5309823522560272e-10,0.2844498991355135,443.7129300575241,10.067586184628617,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,362.7,2.012,,,72.0,10.41,49.0,9.81,40.3,0.0048497067,-0.15000860000000002,45.2,1.965291267879367,10.41667351228233,1.5309823522560272e-10,0.2844498991355135,443.7129300575241,10.067586184628617,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,395.0,368.1,1.953,,,54.0,13.69,36.75,12.81,30.85,0.0069955899999999994,-0.10267949999999999,44.8,1.403458974736089,13.70500239840579,5.6759341803537717e-11,0.12064972102859052,110.09537610376569,8.961059874112506,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G54M(H)-395,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,395.0,366.3,1.952,,,54.0,13.69,36.75,12.81,30.85,0.00621526,-0.11175674999999999,43.8,1.4707649126526035,13.702258727615087,1.8854350225547362e-10,0.10911971676973999,121.86003403131132,10.28230540738198,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6G72M-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,400.0,367.6,2.053,,,72.0,10.33,48.9,9.81,40.8,0.00465883,-0.1645974,45.3,1.9591954022937903,10.33132744974719,1.490388322634472e-10,0.2199287941191131,1711.4508525235,-0.1084162850910597,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,367.3,1.98,,,72.0,10.48,49.2,9.88,40.5,0.0060888800000000005,-0.17603760000000002,46.3,1.9766262399600738,10.486294972442435,1.6078036856006718e-10,0.2789572013366338,464.4137393647677,-5.731080943335567,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,367.3,1.98,,,72.0,10.48,49.2,9.88,40.5,0.0060888800000000005,-0.17603760000000002,46.3,1.9766262399600738,10.486294972442435,1.6078036856006718e-10,0.2789572013366338,464.4137393647677,-5.731080943335567,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,367.8,2.01,,,72.0,10.43,49.1,9.89,40.5,0.00332717,-0.1578565,45.0,1.9412804779329766,10.432373758489431,1.077131105222439e-10,0.27664755712355066,1215.5551805645073,1.9988970597083666,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,367.8,2.01,,,72.0,10.43,49.1,9.89,40.5,0.00332717,-0.1578565,45.0,1.9412804779329766,10.432373758489431,1.077131105222439e-10,0.27664755712355066,1215.5551805645073,1.9988970597083666,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M(H)-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,400.0,375.7,2.05,,,72.0,10.2,49.1,9.67,41.4,0.0045492,-0.13153890000000001,42.44,1.8491298581584217,10.203993095858575,2.970621912977757e-11,0.2010402918292753,513.5391385480277,10.504095892977588,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,400.0,375.7,2.05,,,72.0,10.2,49.1,9.67,41.4,0.0045492,-0.13153890000000001,42.44,1.8491298581584217,10.203993095858575,2.970621912977757e-11,0.2010402918292753,513.5391385480277,10.504095892977588,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M(H)-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,367.4,2.012,,,72.0,10.48,49.2,9.88,40.5,0.004882317600000001,-0.15062088,45.2,1.9738472889031484,10.486357450651811,1.5523226841548986e-10,0.2795552371870567,460.8355282963705,10.129570462834586,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,367.4,2.012,,,72.0,10.48,49.2,9.88,40.5,0.004882317600000001,-0.15062088,45.2,1.9738472889031484,10.486357450651811,1.5523226841548986e-10,0.2795552371870567,460.8355282963705,10.129570462834586,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,400.0,372.9,1.953,,,54.0,13.78,37.0,12.89,31.05,0.00704158,-0.103378,44.8,1.4130059692811547,13.795439343978543,5.711178669860268e-11,0.12152583316931015,108.46484138720497,8.959110908870189,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G54M(H)-400,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,400.0,371.1,1.952,,,54.0,13.78,37.0,12.89,31.05,0.00625612,-0.11251699999999999,43.8,1.480770283620817,13.792644591051756,1.897158701063108e-10,0.10999112464713913,119.86767567793684,10.280387848677792,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6G72M-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,405.0,372.4,2.05,,,72.0,10.37,49.1,9.86,41.1,0.0046768700000000005,-0.16527060000000002,45.3,1.9670004264099192,10.370004469761211,1.4961467512528985e-10,0.2050007672446246,475639.8390454861,-0.11691044890447475,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,405.0,382.5,1.95,,,54.0,13.5,38.0,13.08,31.0,0.0062552250000000005,-0.0904856,43.3,1.3471733289383205,13.500002492605537,7.587474540931457e-12,0.17774869424627168,962596.1619737047,8.785264926995428,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,372.0,1.98,,,72.0,10.56,49.3,9.96,40.7,0.00613536,-0.1763954,46.3,1.98343661249573,10.565858939018613,1.6782688579488522e-10,0.2636510606686073,475.19788623586265,-5.463010169160097,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,372.0,1.98,,,72.0,10.56,49.3,9.96,40.7,0.00613536,-0.1763954,46.3,1.98343661249573,10.565858939018613,1.6782688579488522e-10,0.2636510606686073,475.19788623586265,-5.463010169160097,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,372.6,2.01,,,72.0,10.5,49.3,9.96,40.7,0.0033494999999999996,-0.15849950000000002,45.0,1.9497376002388511,10.502133997979284,1.0924907959298116e-10,0.2718715981840661,1337.7014889217633,2.058940383109869,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,372.6,2.01,,,72.0,10.5,49.3,9.96,40.7,0.0033494999999999996,-0.15849950000000002,45.0,1.9497376002388511,10.502133997979284,1.0924907959298116e-10,0.2718715981840661,1337.7014889217633,2.058940383109869,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M(H)-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,405.0,380.6,2.05,,,72.0,10.26,49.3,9.72,41.7,0.00457596,-0.13207470000000002,42.44,1.860293357888231,10.264148047171378,3.143528751176816e-11,0.18502749178646394,457.65682325451826,10.962359159710422,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,405.0,380.6,2.05,,,72.0,10.26,49.3,9.72,41.7,0.00457596,-0.13207470000000002,42.44,1.860293357888231,10.264148047171378,3.143528751176816e-11,0.18502749178646394,457.65682325451826,10.962359159710422,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M(H)-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,372.2,2.012,,,72.0,10.56,49.3,9.96,40.7,0.004919587200000001,-0.15092702000000002,45.2,1.9805313055926272,10.565921270711927,1.6180552724140505e-10,0.2642725371646496,471.3039420136938,10.429550230547378,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,372.2,2.012,,,72.0,10.56,49.3,9.96,40.7,0.004919587200000001,-0.15092702000000002,45.2,1.9805313055926272,10.565921270711927,1.6180552724140505e-10,0.2642725371646496,471.3039420136938,10.429550230547378,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,405.0,377.6,1.953,,,54.0,13.86,37.25,12.97,31.24,0.00708246,-0.10407649999999999,44.8,1.4217906663702766,13.875424298451554,5.667224285084568e-11,0.12344424954244082,110.92480604791555,8.838259487183347,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G54M(H)-405,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,405.0,375.9,1.952,,,54.0,13.86,37.25,12.97,31.24,0.006292440000000001,-0.11327725,43.8,1.489939711632217,13.872622806398157,1.882620558750803e-10,0.11192188177400461,122.89163205383353,10.15886192255575,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6G72M-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,410.0,377.1,2.053,,,72.0,10.41,49.3,9.91,41.4,0.00469491,-0.1659438,45.3,1.9797430618252037,10.410181308712533,1.593571786834324e-10,0.18924210306779618,10865.501742416345,0.3616303239563259,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,410.0,387.3,1.95,,,54.0,13.57,38.2,13.15,31.2,0.006287659500000001,-0.09096184000000002,43.3,1.355002784664869,13.570002453722449,7.745065002425412e-12,0.17420336575052042,963314.9048236902,8.922462775873376,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,376.7,1.98,,,72.0,10.63,49.5,10.03,40.9,0.00617603,-0.177111,46.3,1.992031217114504,10.635566514182177,1.701636838185457e-10,0.2589681355529446,494.53418097116753,-5.408970823658383,-0.3994,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TP672M-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,376.7,1.98,,,72.0,10.63,49.5,10.03,40.9,0.00617603,-0.177111,46.3,1.992031217114504,10.635566514182177,1.701636838185457e-10,0.2589681355529446,494.53418097116753,-5.408970823658383,-0.3994,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,377.3,2.01,,,72.0,10.58,49.5,10.04,40.9,0.00337502,-0.1591425,45.0,1.9534047977965017,10.580005955829936,1.0454393822475904e-10,0.2678413843069323,475823.57827593427,1.625603895980118,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,377.3,2.01,,,72.0,10.58,49.5,10.04,40.9,0.00337502,-0.1591425,45.0,1.9534047977965017,10.580005955829936,1.0454393822475904e-10,0.2678413843069323,475823.57827593427,1.625603895980118,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M(H)-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,410.0,385.4,2.05,,,72.0,10.32,49.5,9.77,42.0,0.00460272,-0.13261050000000002,42.44,1.871460057093646,10.324222688215697,3.3245307315507113e-11,0.16918127680935852,413.4690293693212,11.417340420529758,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6G72M-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,410.0,385.4,2.05,,,72.0,10.32,49.5,9.77,42.0,0.00460272,-0.13261050000000002,42.44,1.871460057093646,10.324222688215697,3.3245307315507113e-11,0.16918127680935852,413.4690293693212,11.417340420529758,-0.3573,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M(H)-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,376.9,2.012,,,72.0,10.63,49.5,10.03,40.9,0.004952198100000001,-0.15153930000000002,45.2,1.9890882248519774,10.635628386873154,1.6400852775053806e-10,0.25959362021101684,490.2790953407376,10.489766947968555,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6H72M-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,376.9,2.012,,,72.0,10.63,49.5,10.03,40.9,0.004952198100000001,-0.15153930000000002,45.2,1.9890882248519774,10.635628386873154,1.6400852775053806e-10,0.25959362021101684,490.2790953407376,10.489766947968555,-0.41674,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,410.0,382.4,1.953,,,54.0,13.94,37.5,13.05,31.43,0.00712334,-0.104775,44.8,1.430575808123991,13.955398417279534,5.6244013901658534e-11,0.125339061892251,113.46793031618999,8.719090735494536,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G54M(H)-410,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,410.0,380.7,1.952,,,54.0,13.94,37.5,13.05,31.43,0.00632876,-0.11403749999999999,43.8,1.4991096965842867,13.952590077042506,1.868457442267096e-10,0.11382885831308388,126.03372670842653,10.039037835256547,-0.4019,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6G72M-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,415.0,381.9,2.05,,,72.0,10.45,49.5,9.96,41.7,0.00471295,-0.16661700000000002,45.3,1.991139963899982,10.45000292830894,1.669150357137573e-10,0.17391759987578514,620697.2811148441,0.7041098497475727,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,415.0,392.1,1.95,,,54.0,13.64,38.4,13.22,31.4,0.006320094000000001,-0.09143808,43.3,1.3628322545243408,13.640002414892452,7.904323104375743e-12,0.17069219533813745,964023.0198678169,9.058235132500002,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M(H)-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,415.0,381.5,1.98,,,72.0,10.7,49.8,10.1,41.1,0.0062166999999999995,-0.1781844,46.3,2.0023542968412213,10.705358129514416,1.6770282211133736e-10,0.26442929396128745,528.0562566287705,-5.571674617659333,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP672M-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,415.0,381.5,1.98,,,72.0,10.7,49.8,10.1,41.1,0.0062166999999999995,-0.1781844,46.3,2.0023542968412213,10.705358129514416,1.6770282211133736e-10,0.26442929396128745,528.0562566287705,-5.571674617659333,-0.3994,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,415.0,382.1,2.01,,,72.0,10.66,49.8,10.11,41.1,0.0034005399999999996,-0.160107,45.0,1.969355424631022,10.662293349944765,1.1067204050684335e-10,0.2719571442811779,1264.1174253853442,2.0416516701235303,-0.416,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,415.0,382.1,2.01,,,72.0,10.66,49.8,10.11,41.1,0.0034005399999999996,-0.160107,45.0,1.969355424631022,10.662293349944765,1.1067204050684335e-10,0.2719571442811779,1264.1174253853442,2.0416516701235303,-0.416,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TP7F54M(H)-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,415.0,387.2,1.953,,,54.0,14.02,37.75,13.13,31.64,0.00716422,-0.1054735,44.8,1.4398394215445287,14.035179725698745,5.631155725635182e-11,0.1254525321469757,115.86800389044171,8.677743585530987,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G54M(H)-415,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,415.0,385.4,1.952,,,54.0,14.02,37.75,13.13,31.64,0.00636508,-0.11479774999999999,43.8,1.50880358849033,14.032384015475115,1.8707118368122524e-10,0.11394152398083572,128.99371902440058,9.997432996826928,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6G72M-420,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,420.0,386.6,2.05,,,72.0,10.49,49.7,10.01,42.0,0.00473099,-0.16729020000000003,45.3,2.003217281358738,10.490002707299181,1.7615188526627267e-10,0.15861666016684045,614645.3807717413,1.1104327722182352,-0.409,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-420,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,420.0,397.0,1.95,,,54.0,13.71,38.6,13.3,31.6,0.0063525285,-0.09191432000000001,43.3,1.371090255043365,13.710002335569241,8.136544235790836e-12,0.16449223612095915,965488.1388157019,9.271329513789373,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M(H)-420,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,420.0,386.8,2.01,,,72.0,10.73,50.0,10.16,41.4,0.00342287,-0.16075,45.0,1.9824170429589993,10.733557203922208,1.1870012652794234e-10,0.25563461910144886,771.0999415731781,2.5708051525059354,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6F72M-420,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,420.0,386.8,2.01,,,72.0,10.73,50.0,10.16,41.4,0.00342287,-0.16075,45.0,1.9824170429589993,10.733557203922208,1.1870012652794234e-10,0.25563461910144886,771.0999415731781,2.5708051525059354,-0.416,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G48M-425,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,425.0,402.5,2.0,,,48.0,15.68,34.55,14.82,28.68,0.007056,-0.08326549999999999,44.2,1.1925610410112,15.695857294450764,4.044451041263132e-12,0.14193101574853706,140.344138588592,0.8803139666734946,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-425,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,425.0,401.8,1.95,,,54.0,13.78,38.8,13.37,31.8,0.0063849630000000004,-0.09239055999999998,43.3,1.3789202860814855,13.780002296772048,8.300198482416195e-12,0.16105024266985976,966160.7372919586,9.404009040039021,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G48M-430,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,430.0,407.4,2.0,,,48.0,15.72,34.76,14.87,28.92,0.007074,-0.08377159999999999,44.2,1.200660889671072,15.734533534391117,4.142012107910702e-12,0.13741217766497602,148.63001506337935,1.05518608676347,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-430,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,430.0,406.6,1.95,,,54.0,13.67,39.0,13.16,32.68,0.0063339945000000005,-0.0928668,43.3,1.365962439992729,13.670003836693413,5.4462229135696195e-12,0.15336973903499013,546453.6625178987,5.755758769616942,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M(H)-430,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,430.0,398.3,2.17,,,72.0,11.26,48.8,10.73,40.1,0.0066659200000000005,-0.1475224,45.2,1.8893262992631312,11.26000515055139,6.823504208322175e-11,0.2779832326602271,607753.7887287909,3.6002230518912137,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M-430,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,430.0,398.3,2.17,,,72.0,11.26,48.8,10.73,40.1,0.0066659200000000005,-0.1475224,45.2,1.8893262992631312,11.26000515055139,6.823504208322175e-11,0.2779832326602271,607753.7887287909,3.6002230518912137,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6I72M-435,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,435.0,402.9,2.17,,,72.0,11.16,49.8,10.51,41.4,0.00837,-0.1485036,45.3,1.9747284262325364,11.167630444598117,1.229655146206924e-10,0.22772913330478042,333.0680411060258,10.079801025529674,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G48M-435,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,435.0,412.2,2.0,,,48.0,15.76,34.98,14.89,29.22,0.007091999999999999,-0.0843018,44.2,1.211212549490463,15.775254866450608,4.448343018426029e-12,0.1289699045376044,133.240478024808,1.6380686148125125,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-435,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,435.0,411.5,1.95,,,54.0,13.94,39.2,13.51,32.2,0.006459099,-0.09334304,43.3,1.3937473839732024,13.940002298449889,8.50086093840631e-12,0.15924661214425154,965727.7175887662,9.514619717750445,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M(H)-435,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,435.0,403.0,2.17,,,72.0,11.33,49.0,10.8,40.3,0.00670736,-0.148127,45.2,1.8981903969478162,11.330003028926814,6.971472472266235e-11,0.26731240897674896,999999.8644702794,3.7279944400806393,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M-435,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,435.0,403.0,2.17,,,72.0,11.33,49.0,10.8,40.3,0.00670736,-0.148127,45.2,1.8981903969478162,11.330003028926814,6.971472472266235e-11,0.26731240897674896,999999.8644702794,3.7279944400806393,-0.377,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6I72M-440,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,440.0,407.7,2.17,,,72.0,11.22,50.0,10.58,41.6,0.008415,-0.1491,45.3,1.9652320942547377,11.220008566470966,1.001247862048935e-10,0.22709290032958845,297445.8731176091,8.175544310769393,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G48M-440,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,440.0,417.1,2.0,,,48.0,15.8,35.2,14.91,29.52,0.00711,-0.084832,44.2,1.2217779735223397,15.815735097423685,4.773103933008288e-12,0.12054926659911512,121.04649644971487,2.2163351779127742,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-440,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,440.0,416.3,1.95,,,54.0,13.77,39.3,13.36,32.94,0.006380329499999999,-0.09358116,43.3,1.4094434310488504,13.770001480468528,1.069914476756014e-11,0.10531263791729038,979420.814381947,11.705479467281199,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M(H)-440,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,440.0,407.8,2.17,,,72.0,11.4,49.2,10.87,40.5,0.0067488,-0.14873160000000002,45.2,1.9068107977128372,11.400005138326451,7.097887972812942e-11,0.26910858770905305,597082.9866807457,3.827038764800452,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M-440,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,440.0,407.8,2.17,,,72.0,11.4,49.2,10.87,40.5,0.0067488,-0.14873160000000002,45.2,1.9068107977128372,11.400005138326451,7.097887972812942e-11,0.26910858770905305,597082.9866807457,3.827038764800452,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-440,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,440.0,408.1,2.164,,,60.0,13.69,40.99,12.81,34.35,0.00621526,-0.12465059,43.8,1.63889966989596,13.702723966208751,1.8416159490932928e-10,0.1270909138500287,136.7399623299573,10.07303308204689,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6I72M-445,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,445.0,412.5,2.17,,,72.0,11.29,50.2,10.65,41.8,0.0084675,-0.1496964,45.3,1.9906444062659947,11.29642621601982,1.2470717788071537e-10,0.2198006556945993,386.16030250029667,10.096251909924328,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G48M-445,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,445.0,421.9,2.0,,,48.0,15.83,35.42,14.94,29.79,0.0071235,-0.0853622,44.2,1.2310310280967036,15.84497647382685,4.965986772435537e-12,0.1145696348024112,121.09908793629441,2.5353836660641575,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-445,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,445.0,421.2,1.95,,,54.0,13.82,39.45,13.46,33.07,0.006403497000000001,-0.09393834000000001,43.3,1.4171854901568408,13.82000142769495,1.1248902647726156e-11,0.08991762042218543,870087.5817627902,12.130219780617974,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M(H)-445,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,445.0,412.6,2.17,,,72.0,11.47,49.4,10.94,40.7,0.006790240000000001,-0.1493362,45.2,1.915551623657869,11.47000512902016,7.237299095126621e-11,0.26475706373582336,592107.211801311,3.938909668123056,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M-445,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,445.0,412.6,2.17,,,72.0,11.47,49.4,10.94,40.7,0.006790240000000001,-0.1493362,45.2,1.915551623657869,11.47000512902016,7.237299095126621e-11,0.26475706373582336,592107.211801311,3.938909668123056,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-445,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,445.0,412.9,2.164,,,60.0,13.78,41.16,12.89,34.53,0.00625612,-0.12516755999999998,43.8,1.6469678370895335,13.792733580524372,1.8889164907078347e-10,0.12335234975329025,133.4891960196404,10.241610214351697,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6I72M-450,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,450.0,417.2,2.17,,,72.0,11.36,50.4,10.72,42.0,0.00852,-0.1502928,45.3,1.982980701323951,11.360008153046595,1.0404484709069292e-10,0.2187271396950907,304771.9135689536,8.403584994100779,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G48M-450,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,450.0,426.8,2.0,,,48.0,15.86,35.64,14.96,30.09,0.007136999999999999,-0.0858924,44.2,1.2412511921599294,15.874567564539245,5.276094967971137e-12,0.10630064575633712,115.73164744991651,3.036491730565029,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G54M-450,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,450.0,426.0,1.95,,,54.0,13.87,39.6,13.56,33.2,0.0064266645,-0.09429552000000001,43.3,1.4249597918835448,13.870001153220986,1.1828221622767547e-11,0.07254308220635593,872167.3209154439,12.5575293813239,-0.31976,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M(H)-450,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,450.0,417.4,2.17,,,72.0,11.54,49.6,11.01,40.9,0.00683168,-0.1499408,45.2,1.924291520804666,11.540005117615358,7.378188281042238e-11,0.26046127600812036,587360.756795907,4.0497747027891435,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M-450,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,450.0,417.4,2.17,,,72.0,11.54,49.6,11.01,40.9,0.00683168,-0.1499408,45.2,1.924291520804666,11.540005117615358,7.378188281042238e-11,0.26046127600812036,587360.756795907,4.0497747027891435,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-450,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,450.0,417.7,2.164,,,60.0,13.86,41.33,12.97,34.7,0.006292440000000001,-0.12568453,43.8,1.6541356495817803,13.872321430771702,1.9111572187112222e-10,0.1207497199006396,135.82766447254173,10.292805206928536,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6I72M-455,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,455.0,422.0,2.17,,,72.0,11.43,50.6,10.79,42.2,0.0085725,-0.1508892,45.3,1.9918492573918811,11.43000651354162,1.060300556211842e-10,0.2146268514077865,376643.3022534545,8.515624568806997,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M(H)-455,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,455.0,422.1,2.17,,,72.0,11.61,49.8,11.08,41.1,0.00687312,-0.1505454,45.2,1.9330305037888793,11.610005104140484,7.520554338040786e-11,0.25622016226211053,582835.9335863249,4.159647616069388,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP6L72M-455,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,455.0,422.1,2.17,,,72.0,11.61,49.8,11.08,41.1,0.00687312,-0.1505454,45.2,1.9330305037888793,11.610005104140484,7.520554338040786e-11,0.25622016226211053,582835.9335863249,4.159647616069388,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-455,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,455.0,422.4,2.164,,,60.0,13.94,41.5,13.05,34.87,0.00632876,-0.1262015,43.8,1.6613038360614365,13.951918411236694,1.9335049015861482e-10,0.1181791415707701,138.22457087329408,10.343620980449893,-0.4019,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD6I72M-460,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,460.0,426.8,2.17,,,72.0,11.5,50.8,10.86,42.4,0.008625,-0.15148560000000003,45.3,2.0158830904530123,11.505618850646735,1.2948265010909266e-10,0.20780073325739934,425.30202486314465,10.263740584198366,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G60M(H)-460,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,460.0,427.2,2.164,,,60.0,14.02,41.67,13.13,35.04,0.00636508,-0.12671847,43.8,1.6684723877061483,14.031524373095499,1.955958890645365e-10,0.11564002716246165,140.68211888552884,10.39406134156143,-0.4019,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G72M-530,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,530.0,489.2,2.591,,,72.0,13.72,49.32,12.83,41.32,0.00801248,-0.1447542,45.4,1.976098554178514,13.733145878556856,1.9437463509665312e-10,0.15280405839453212,159.47749169418748,14.394409178935291,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-530,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,530.0,494.0,2.591,,,72.0,13.72,49.32,12.83,41.32,0.007010920000000001,-0.13780008,44.8,1.8821404597690978,13.736112480778383,5.578758469035622e-11,0.16884826553019147,143.77663232649923,8.791694867853357,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M-530,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,530.0,494.0,2.591,,,72.0,13.72,49.32,12.83,41.32,0.007010920000000001,-0.13780008,44.8,1.8821404597690978,13.736112480778383,5.578758469035622e-11,0.16884826553019147,143.77663232649923,8.791694867853357,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G72M(H)-530,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,530.0,491.7,2.591,,,72.0,13.72,49.32,12.83,41.32,0.006228880000000001,-0.14998212,43.8,1.9723401057631404,13.733258151382552,1.8532951544256185e-10,0.15344022984037908,158.78533497789576,10.11215059325898,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G72M-535,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,535.0,493.9,2.591,,,72.0,13.79,49.46,12.9,41.48,0.008053359999999999,-0.1451651,45.4,1.9824507304374503,13.802685946358062,1.9726422351956198e-10,0.14866979784993564,161.60848482770635,14.482677686173627,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-535,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,535.0,498.8,2.591,,,72.0,13.79,49.46,12.9,41.48,0.0070466899999999996,-0.13819124,44.8,1.888167537772023,13.805608557119523,5.662533326291127e-11,0.16469275340060044,145.50435843172798,8.87697279906684,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M-535,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,535.0,498.8,2.591,,,72.0,13.79,49.46,12.9,41.48,0.0070466899999999996,-0.13819124,44.8,1.888167537772023,13.805608557119523,5.662533326291127e-11,0.16469275340060044,145.50435843172798,8.87697279906684,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G72M(H)-535,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,535.0,496.5,2.591,,,72.0,13.79,49.46,12.9,41.48,0.00626066,-0.15040786,43.8,1.9786873746499363,13.802796207158446,1.8810508720543157e-10,0.14930376243305002,160.89915674381263,10.197813322610225,-0.4019,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G72M-540,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,540.0,498.7,2.58,,,72.0,13.86,49.6,12.97,41.64,0.00809424,-0.145576,45.4,1.9888029938778018,13.87223531479409,2.001791940217873e-10,0.1445806129008945,163.77897794734116,14.570448961699775,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-540,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,540.0,503.6,2.591,,,72.0,13.86,49.6,12.97,41.64,0.00708246,-0.1385824,44.8,1.8941947261153913,13.8751139687674,5.747059972148747e-11,0.16058252936982165,147.25939362847305,8.961774426327247,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M-540,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,540.0,503.6,2.591,,,72.0,13.86,49.6,12.97,41.64,0.00708246,-0.1385824,44.8,1.8941947261153913,13.8751139687674,5.747059972148747e-11,0.16058252936982165,147.25939362847305,8.961774426327247,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G72M(H)-540,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,540.0,501.2,2.591,,,72.0,13.86,49.6,12.97,41.64,0.006292440000000001,-0.1508336,43.8,1.9850347491496831,13.872343572515833,1.9090536573768192e-10,0.14521238949805598,163.051966940341,10.282994991972398,-0.4019,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G72M-545,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,545.0,503.5,2.58,,,72.0,13.93,49.76,13.04,41.8,0.008135120000000001,-0.1460456,45.4,1.9955217285242652,13.941902369896981,2.020245533138922e-10,0.14208992431978462,166.29568067230187,14.60754433055536,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-545,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,545.0,508.4,2.591,,,72.0,13.93,49.76,13.04,41.8,0.0071182300000000006,-0.13902943999999998,44.8,1.9005845862193274,13.944749979057827,5.800398526753914e-11,0.1580670531707607,149.27980988744775,8.997564333845634,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M-545,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,545.0,508.4,2.591,,,72.0,13.93,49.76,13.04,41.8,0.0071182300000000006,-0.13902943999999998,44.8,1.9005845862193274,13.944749979057827,5.800398526753914e-11,0.1580670531707607,149.27980988744775,8.997564333845634,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G72M(H)-545,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,545.0,506.0,2.591,,,72.0,13.93,49.76,13.04,41.8,0.006324220000000001,-0.15132015999999998,43.8,1.9917436308965035,13.942009281614238,1.9267359051818472e-10,0.142720180960159,165.5463032106562,10.318948173601568,-0.4019,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G72M-550,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,550.0,508.3,2.58,,,72.0,14.0,49.92,13.11,41.96,0.008176000000000001,-0.1465152,45.4,2.0022412764382227,14.01157557271183,2.0387789236238984e-10,0.1396257885275673,168.86949330184873,14.644485208268554,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-550,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,550.0,513.2,2.591,,,72.0,14.0,49.92,13.11,41.96,0.007154000000000001,-0.13947648,44.8,1.9069751270781947,14.014392148726598,5.853966003153184e-11,0.15557841275469347,151.3393059326555,9.033197597276395,-0.3581,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G72M(H)-550,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,550.0,510.8,2.591,,,72.0,14.0,49.92,13.11,41.96,0.006356000000000001,-0.15180672,43.8,1.9984531083032846,14.01168114771551,1.9444899763208494e-10,0.1402545770000328,168.09684994644093,10.354727292237193,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G72M-555,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,555.0,513.0,2.58,,,72.0,14.07,50.05,13.18,42.12,0.008216880000000001,-0.14689674999999996,45.4,2.00841085566953,14.08109696276269,2.0740050122538733e-10,0.13488196730023808,171.0188074064603,14.755988083320457,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-555,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,555.0,524.5,2.58,,,72.0,13.65,51.4,12.91,43.13,0.0063247275,-0.12239368,43.3,1.843417298271072,13.659810476516727,1.0467021851416439e-11,0.19111324190220397,265.90917952102296,11.641367804693921,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7F72M(H)-555,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,0,555.0,518.0,2.591,,,72.0,14.07,50.08,13.18,42.12,0.007189770000000001,-0.13992352,44.8,1.9133662506196634,14.08404038880854,5.907754588750748e-11,0.15311619539154406,153.43911895296938,9.068665263561053,-0.3581,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TP7G72M(H)-555,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,555.0,515.6,2.591,,,72.0,14.07,50.08,13.18,42.12,0.006387780000000001,-0.15229328,43.8,2.0051633215059432,14.08135907871161,1.962319269049454e-10,0.13781512921808559,170.70565085167925,10.390350471369747,-0.4019,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-560,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,560.0,529.4,2.58,,,72.0,13.71,51.6,12.96,43.28,0.0063525285,-0.12286992000000001,43.3,1.8506693012532844,13.7203530413918,1.0519565773059189e-11,0.1925409993924751,254.97210462731118,11.649355437823436,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-565,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,565.0,534.2,2.58,,,72.0,13.77,51.8,13.01,43.43,0.006380329499999999,-0.12334616,43.3,1.857920960522002,13.780902757935461,1.0572067230710838e-11,0.1939579948594244,244.96568793168993,11.657231456341993,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G78M-570,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,570.0,536.5,2.795,,,78.0,13.65,53.3,12.76,44.68,0.006033300000000001,-0.1356485,43.3,1.9587634536998724,13.668563972474885,2.0234913082301253e-11,0.19435607000382724,142.90908733496912,10.241673009689688,-0.3351,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-570,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,570.0,539.1,2.58,,,72.0,13.83,52.1,13.08,43.58,0.0064081305,-0.12406052000000001,43.3,1.8657096822015382,13.840389303865447,1.0171260915030363e-11,0.20318345747950478,270.47310012933673,11.259915467494782,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G78M-575,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,575.0,541.3,2.795,,,78.0,13.72,53.44,12.83,44.82,0.006064240000000001,-0.1360048,43.3,1.9640661610885692,13.738200831495453,2.039075950522561e-11,0.1918890513956813,144.64821531429536,10.263167139944972,-0.3351,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G78M-580,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,580.0,546.2,2.795,,,78.0,13.79,53.59,12.9,44.97,0.00609518,-0.13638655000000002,43.3,1.9697736956126266,13.807830860149034,2.0557457086728782e-11,0.1893407033468787,146.43198845408062,10.289130024448449,-0.3351,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-580,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,580.0,548.7,2.58,,,72.0,13.95,52.5,13.22,43.88,0.0064637324999999995,-0.125013,43.3,1.877589363328521,13.958716500599657,9.917218654955009e-12,0.20611505237804056,329.8691923000751,10.94193886963513,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G78M-585,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,585.0,551.0,2.795,,,78.0,13.86,53.73,12.97,45.11,0.0061261200000000005,-0.13674285,43.3,1.975079245237504,13.877477972338754,2.071483410373136e-11,0.18692678934301288,148.23260149717817,10.310710053244911,-0.3351,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-585,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,585.0,554.3,2.7,,,66.0,15.68,47.5,14.82,39.5,0.007056,-0.11447500000000001,44.2,1.6409385222218138,15.695559702932973,4.143726023360583e-12,0.18973735743826511,191.2042779950407,1.0833789458989613,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-585,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,585.0,553.6,2.58,,,72.0,14.01,52.7,13.29,44.02,0.0064915335000000005,-0.12548924,43.3,1.8833320618801577,14.017874179271761,9.765389526063636e-12,0.20841401223876474,370.8171031113908,10.758287035499631,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TD7G78M-590,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,590.0,555.8,2.795,,,78.0,13.93,53.87,13.04,45.25,0.006157060000000001,-0.13709915,43.3,1.9803861258934166,13.947130029285024,2.08729361518532e-11,0.1845385037505734,150.06520554114803,10.332328956099149,-0.3351,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-590,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,590.0,559.1,2.7,,,66.0,15.72,47.8,14.87,39.7,0.007074,-0.115198,44.2,1.6497212911540733,15.734798418880679,4.044967735485755e-12,0.19425567492613505,206.35307315896586,0.856701596914097,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-590,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,590.0,558.4,2.58,,,72.0,13.94,52.38,13.28,44.43,0.006459099,-0.12472725600000001,43.3,1.8820080886683554,13.943505554876245,1.1333436299423973e-11,0.15033400739548616,597.8100905949858,12.145154449517525,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-595,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,595.0,564.0,2.7,,,66.0,15.76,48.1,14.89,40.0,0.007091999999999999,-0.11592100000000001,44.2,1.6619684084010078,15.776089755548185,4.184998855217019e-12,0.1910695333344676,187.15361079362938,1.1253478181677954,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-595,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,595.0,563.3,2.58,,,72.0,13.99,52.59,13.33,44.63,0.0064822665,-0.125227308,43.3,1.889839774874882,13.99337937987844,1.142403681536163e-11,0.14855206111008226,614.9777237144683,12.184594187154635,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-600,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,600.0,568.8,2.7,,,66.0,15.8,48.4,14.91,40.3,0.00711,-0.116644,44.2,1.6742300663892635,15.817313899367507,4.328876352032134e-12,0.1878879793241906,171.4593532947354,1.3926815352074464,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G72M-600,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,600.0,568.2,2.58,,,72.0,14.04,52.8,13.39,44.83,0.006505434,-0.12572736,43.3,1.897015972319438,14.04276296335516,1.1414575837805998e-11,0.14688138573725953,746.3785707308143,12.139995748048818,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-605,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,605.0,573.7,2.7,,,66.0,15.83,48.7,14.94,40.5,0.0071235,-0.11736700000000001,44.2,1.6835384506715096,15.847464527053422,4.259247525985111e-12,0.19249228372455401,174.47668865001012,1.2401182767278391,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-605,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,605.0,571.9,2.8,,,78.0,13.59,55.38,12.91,46.87,0.0062969265,-0.131870856,43.3,1.9902839888124417,13.595455501167965,1.1089763496665089e-11,0.1718776340164275,428.15810683642894,12.191924386386695,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-610,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,610.0,578.5,2.7,,,66.0,15.86,49.0,14.96,40.8,0.007136999999999999,-0.11809,44.2,1.6953321997656858,15.877902422657856,4.36885700970545e-12,0.18945306273913043,167.83904442035978,1.4399094203106206,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-610,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,610.0,576.7,2.8,,,78.0,13.64,55.59,12.97,47.05,0.006320094000000001,-0.132370908,43.3,1.996984759574328,13.644805003858156,1.101242993005762e-11,0.1718232869618713,487.7560536872739,12.089563708284205,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-615,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,615.0,583.4,2.7,,,66.0,15.9,49.3,15.0,41.0,0.007155,-0.11881299999999999,44.2,1.704611285882383,15.918027947204505,4.300146069520183e-12,0.1939179072713217,171.0286087702146,1.2849552481223705,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-615,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,615.0,581.5,2.8,,,78.0,13.69,55.79,13.02,47.24,0.0063432615,-0.132847148,43.3,2.0044146972208328,13.694663044533984,1.1092518046757171e-11,0.1700231415902054,499.1624687238729,12.121644738309877,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM3G66M-620,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,620.0,588.3,2.7,,,66.0,15.94,49.6,15.05,41.2,0.007172999999999999,-0.119536,44.2,1.71337704828483,15.957312216591003,4.200049479241556e-12,0.19837332615270978,182.64968010847548,1.0629903398936569,-0.292,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-620,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,620.0,586.4,2.8,,,78.0,13.74,55.99,13.08,47.42,0.006366429,-0.13332338800000001,43.3,2.0109304233979026,13.744011781444524,1.1042340405736944e-11,0.16920932975345904,579.527134606785,12.042240597269005,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-625,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,625.0,591.2,2.8,,,78.0,13.79,56.18,13.13,47.61,0.0063895965,-0.133775816,43.3,2.018172139775963,13.79387132167005,1.114834756478419e-11,0.16666994971739368,593.6935281146286,12.09576309154386,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-630,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,630.0,596.1,2.8,,,78.0,13.84,56.37,13.18,47.8,0.006412764,-0.134228244,43.3,2.025413489619005,13.84373377471608,1.1254691721687177e-11,0.16415012523351957,608.4560318030705,12.148878476820885,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-635,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,635.0,600.9,2.8,,,78.0,13.89,56.55,13.24,47.97,0.0064359315,-0.13465686,43.3,2.031353152744664,13.89310523925721,1.1225853515731728e-11,0.16271605389113494,727.8427902072534,12.08794436523522,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM7G78M-640,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,640.0,605.8,2.8,,,78.0,13.94,56.73,13.3,48.15,0.006459099,-0.135085476,43.3,2.037496679689209,13.942484171581855,1.1228350659375818e-11,0.1604385650570228,900.3056123050611,12.052766547411736,-0.31976,N,2025.7.3,6/23/2025,4.0,first_pass +Suzhou Talesun Solar Technologies Co Ltd TM8G66M-705,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,705.0,665.9,3.08,,,66.0,18.36,48.8,17.33,40.7,0.010098,-0.15128,41.9,1.8716615394437766,18.37182546496567,8.614301359402142e-11,0.135144870125125,209.8234507266684,-0.9678293359465865,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TM8G66M-710,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,710.0,670.7,3.08,,,66.0,18.4,49.0,17.36,40.9,0.01012,-0.1519,41.9,1.8805829179046787,18.41222291033735,8.778751799340512e-11,0.13315442120926205,200.44664730271535,-0.8318728708362921,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TM8G66M-715,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,715.0,675.6,3.08,,,66.0,18.44,49.2,17.4,41.1,0.010142,-0.15252000000000002,41.9,1.8889507226545792,18.451967716718087,8.88287694756764e-11,0.13122177061128773,202.1880647647542,-0.7549820981236042,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TM8G66M-720,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,720.0,680.4,3.08,,,66.0,18.49,49.4,17.44,41.3,0.0101695,-0.15314,41.9,1.8978443716721471,18.502308415118016,9.051638281629023e-11,0.1291785525816872,194.05516029466386,-0.6239142984814793,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TM8G66M-725,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,725.0,685.3,3.08,,,66.0,18.53,49.6,17.47,41.5,0.010191500000000001,-0.15376,41.9,1.9067727999005895,18.542658722785923,9.221178118579707e-11,0.12720966714406237,186.2111378811817,-0.4902872685183643,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Suzhou Talesun Solar Technologies Co Ltd TM8G66M-730,Suzhou Talesun Solar Technologies Co Ltd,Mono-c-Si,1,730.0,690.1,3.08,,,66.0,18.57,49.8,17.51,41.7,0.0102135,-0.15438,41.9,1.9151405355006539,18.58239156522176,9.327454738625122e-11,0.1253032446723973,187.77944944140373,-0.4156985423859558,-0.36,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM395DMH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,395.0,369.0,1.95,,,54.0,13.5,36.81,12.81,30.85,0.006520500000000001,-0.1071171,44.6,1.3814311236236108,13.505014371392434,3.587463663118496e-11,0.13076974210017492,352.06641462403235,0.8753418875775957,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM395MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,395.0,366.9,1.95,,,54.0,13.5,36.81,12.81,30.85,0.006196500000000001,-0.09865080000000001,46.0,1.375035553633444,13.505208166947947,3.168597362942456e-11,0.13187528758999983,341.831671201554,8.529174032956352,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM395MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,395.0,367.7,1.95,,,54.0,13.5,36.81,12.81,30.85,0.006372,-0.10085940000000002,45.2,1.3846376030708256,13.504918211569594,3.8162244794920844e-11,0.13021618893147277,357.43045235139806,7.727875476508799,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM400DMH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,400.0,373.8,1.95,,,54.0,13.6,36.96,12.91,31.0,0.0065688000000000005,-0.1075536,44.6,1.387352212818978,13.604703713358461,3.6357680104374725e-11,0.12820644417475086,370.68748505530465,0.9229547498564002,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM400MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,400.0,371.7,1.95,,,54.0,13.6,36.96,12.91,31.0,0.006242400000000001,-0.09905280000000001,46.0,1.3809217719700726,13.604894193468823,3.210880753636909e-11,0.12930993022835077,359.3268416102671,8.579342338666628,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM400MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,400.0,372.5,1.95,,,54.0,13.6,36.96,12.91,31.0,0.0064192,-0.10127040000000002,45.2,1.3831867086957144,13.600003300857706,3.3790617315163544e-11,0.1288223159156494,530779.9871811692,6.700116889295041,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM405DMH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,405.0,378.6,1.95,,,54.0,13.7,37.11,13.01,31.15,0.0066171,-0.10799009999999999,44.6,1.3932744608439462,13.7044019413922,3.684406903336478e-11,0.12568240667175126,391.1567315003334,0.9703481921606987,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM405MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,405.0,376.5,1.95,,,54.0,13.7,37.11,13.01,31.15,0.006288299999999999,-0.0994548,46.0,1.3868091254849655,13.704589091212561,3.2534521495969393e-11,0.1267838697194074,378.4930318690972,8.629281302676619,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM405MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,405.0,377.3,1.95,,,54.0,13.7,37.11,13.01,31.15,0.006466399999999999,-0.1016814,45.2,1.396499046322814,13.704309611267169,3.918546612395761e-11,0.12513376854892724,397.79287842931086,7.82747375704952,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM410DMH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,410.0,383.4,1.95,,,54.0,13.79,37.26,13.1,31.3,0.00666057,-0.10842659999999998,44.6,1.3992242864758822,13.794135135204108,3.732384835619902e-11,0.1232826276307692,411.12742103138606,1.0214229083208495,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM410MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,410.0,381.3,1.95,,,54.0,13.79,37.26,13.1,31.3,0.00632961,-0.0998568,46.0,1.3750966612338198,13.79483152502231,2.3372986764356543e-11,0.1273765197787462,363.5544101753201,5.702307465218817,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM410MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,410.0,382.1,1.95,,,54.0,13.79,37.26,13.1,31.3,0.00650888,-0.1020924,45.2,1.4024576488875506,13.794044661980534,3.9691416368114066e-11,0.12273601695871258,418.46011289623436,7.88103259922436,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM415DMH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,415.0,388.2,1.95,,,54.0,13.89,37.41,13.2,31.45,0.0067088700000000005,-0.10886309999999999,44.6,1.40514849383563,13.893850184372544,3.781669973335055e-11,0.12083203418903851,435.9160059111391,1.0683179907513138,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM415MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,415.0,386.1,1.95,,,54.0,13.89,37.41,13.2,31.45,0.00637551,-0.10025880000000001,46.0,1.3986126300708053,13.894030770734933,3.3385325548290694e-11,0.1219305102132892,420.17145901619847,8.732537569509754,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM415MH5-54(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,415.0,386.9,1.95,,,54.0,13.89,37.41,13.2,31.45,0.00655608,-0.10250340000000001,45.2,1.4083908919065868,13.893761612855306,4.0211481324695466e-11,0.12028779821344589,444.170525470329,7.9301969053920445,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM430DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,430.0,400.2,1.97388,,,72.0,11.25,48.68,10.72,40.14,0.00554625,-0.12992692000000003,46.2,1.8001767887272744,11.250853216817472,2.0257096871683227e-11,0.2803037198700225,3695.9154347243416,6.59489349693604,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM430MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,430.0,402.4,1.97388,,,72.0,11.25,48.68,10.72,40.14,0.00604125,-0.12739556,45.1,1.7899840798243263,11.251078198510006,1.7361288814004035e-11,0.2823862660940787,2946.4386324382217,7.317305618506515,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM435DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,435.0,405.0,1.97388,,,72.0,11.32,48.88,10.79,40.34,0.00558076,-0.13046072,46.2,1.8081049848252804,11.320637103187558,2.05516063152526e-11,0.2759858928978912,4903.69663984618,6.665105429756385,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM435DMH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,435.0,406.3,2.16,,,60.0,13.34,40.8,12.89,33.76,0.0064432199999999995,-0.11872799999999999,44.6,1.5253071300274217,13.340089640496497,3.2232397101597214e-11,0.18424724810845763,27419.101937224514,0.07664063874581371,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM435MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,435.0,407.2,1.97388,,,72.0,11.32,48.88,10.79,40.34,0.00607884,-0.12791896,45.1,1.7978637690060093,11.32085863947742,1.7613534731247348e-11,0.278065982718735,3665.9232324472205,7.388066651043037,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM435MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,435.0,404.0,2.16,,,60.0,13.34,40.8,12.89,33.76,0.00612306,-0.109344,46.0,1.5186517111717073,13.340002257523015,2.8669922815408362e-11,0.14683834017481734,867411.7608582887,7.728885069224878,-0.352,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM435MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,435.0,404.9,2.16,,,60.0,13.34,40.8,12.89,33.76,0.006296479999999999,-0.111792,45.2,1.5296143265079445,13.34000221573966,3.4757467901980316e-11,0.1439557668689119,866429.9076797658,6.992640331071194,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM440DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,440.0,409.8,1.97388,,,72.0,11.39,49.08,10.86,40.54,0.0056152699999999995,-0.13099452,46.2,1.816033286907234,11.390427023521733,2.0848111146430268e-11,0.2717240910891877,7247.699303214477,6.734752243838326,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM440DMH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,440.0,411.1,2.16,,,60.0,13.41,40.95,12.98,33.91,0.00647703,-0.1191645,44.6,1.5332134513189621,13.410002100775348,3.373070427308397e-11,0.13602902417855553,868046.196832948,0.40248092397521934,-0.35,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM440MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,440.0,412.1,1.97388,,,72.0,11.39,49.08,10.86,40.54,0.00611643,-0.12844236,45.1,1.8057435974903004,11.390645113794982,1.786749739819539e-11,0.27380174849261724,4834.1893236122905,7.458262657138836,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM440MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,440.0,408.8,2.16,,,60.0,13.41,40.95,12.98,33.91,0.0061551900000000005,-0.10974600000000001,46.0,1.5258797868382115,13.410002129411886,2.966719659610462e-11,0.13797265423566168,868602.512812757,7.981821615453461,-0.352,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM440MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,440.0,409.7,2.16,,,60.0,13.41,40.95,12.98,33.91,0.00632952,-0.11220300000000001,45.2,1.5369127053479787,13.410002086736002,3.597033249786776e-11,0.13504861432828297,867591.8669894242,7.244548165641546,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM445DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,445.0,414.6,1.97388,,,72.0,11.46,49.28,10.93,40.74,0.00564978,-0.13152832,46.2,1.8239618438930572,11.460222874610182,2.114665142211209e-11,0.26751720199507256,13755.48521641381,6.803860085780266,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM445DMH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,445.0,415.9,2.16,,,60.0,13.52,41.1,13.07,34.06,0.00653016,-0.119601,44.6,1.5384657685768823,13.520002153868745,3.3793257226267644e-11,0.13810006409607478,866597.1131212579,0.3511655909723188,-0.35,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM445MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,445.0,416.9,1.97388,,,72.0,11.46,49.28,10.93,40.74,0.0061540200000000005,-0.12896575999999998,45.1,1.8136235590468417,11.46043752144101,1.8123169672272546e-11,0.2695924816215631,7061.4377175932095,7.5278998355188325,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM445MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,445.0,413.6,2.16,,,60.0,13.52,41.1,13.07,34.06,0.00620568,-0.11014800000000001,46.0,1.5311246096018174,13.520002182296274,2.973049852029537e-11,0.14001133378985836,867139.6006534077,7.929040593998935,-0.352,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM445MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,445.0,414.4,2.16,,,60.0,13.52,41.1,13.07,34.06,0.0063814399999999995,-0.11261400000000002,45.2,1.5421902360048256,13.520002139865264,3.604539759478353e-11,0.13713039749057396,866147.5102739471,7.1917685847155415,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM450DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,450.0,419.4,1.97388,,,72.0,11.53,49.48,11.0,40.94,0.00568429,-0.13206212,46.2,1.831877965446761,11.530017607521604,2.144340681571163e-11,0.26336646462606816,172462.1446325621,6.870859181306312,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM450DMH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,450.0,420.7,2.16,,,60.0,13.62,41.25,13.16,34.21,0.0065784599999999995,-0.1200375,44.6,1.5442371263495807,13.620002160412179,3.413551287417787e-11,0.13737783447311455,865814.9111541439,0.3731599963327462,-0.35,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM450MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,450.0,421.7,1.97388,,,72.0,11.53,49.48,11.0,40.94,0.006191609999999999,-0.12948916,45.1,1.8215036556276638,11.530235764754762,1.8380546564085648e-11,0.26543712577137507,12981.12079829366,7.596985288679237,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM450MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,450.0,418.4,2.16,,,60.0,13.62,41.25,13.16,34.21,0.00625158,-0.11055000000000001,46.0,1.5368681001171463,13.62000218887297,3.0031824787734015e-11,0.13927505705080578,866352.6839267247,7.952771124005997,-0.352,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM450MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,450.0,419.2,2.16,,,60.0,13.62,41.25,13.16,34.21,0.006428639999999999,-0.11302500000000001,45.2,1.5476699000665297,13.620127721586563,3.621368734387955e-11,0.1750396633761724,18665.940582484593,7.168811694853049,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM455DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,455.0,424.2,1.97388,,,72.0,11.59,49.68,11.07,41.14,0.005713869999999999,-0.13259592,46.2,1.8407721607161416,11.59000515722912,2.2031708847866446e-11,0.25923218585755553,582590.7251683542,7.060594071535523,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM455DMH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,455.0,425.5,2.16,,,60.0,13.72,41.4,13.25,34.36,0.0066267600000000015,-0.12047399999999998,44.6,1.5493355428740287,13.720004311789717,3.4080939903124335e-11,0.17293821819331454,550300.5696249497,0.3007663163715363,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM455MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,455.0,426.5,1.97388,,,72.0,11.59,49.68,11.07,41.14,0.00622383,-0.13001256,45.1,1.8299360625205174,11.59000519792004,1.8777650423707836e-11,0.2613739497602048,582804.35353395,7.737487977704883,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM455MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,455.0,423.1,2.16,,,60.0,13.72,41.4,13.25,34.36,0.006297480000000001,-0.110952,46.0,1.5349229323747433,13.720004353688736,2.6518228685520502e-11,0.17530260691333727,552452.7513683402,6.8068429214655986,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM455MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,455.0,424.0,2.16,,,60.0,13.72,41.4,13.25,34.36,0.006475840000000001,-0.11343600000000001,45.2,1.5518689628928102,13.720004284228082,3.5600527134976456e-11,0.1725234930765385,552513.3161738713,6.956971489236925,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM460DMH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,460.0,429.0,1.97388,,,72.0,11.66,49.88,11.13,41.34,0.00574838,-0.13312972,46.2,1.8483853220682882,11.660005162138516,2.223045193552977e-11,0.25532457655065854,576725.3074140811,7.086289656165254,-0.3493,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM460DMH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,460.0,430.3,2.16,,,60.0,13.82,41.55,13.34,34.49,0.006675060000000001,-0.12091049999999999,44.6,1.5547458075440987,13.820004351061439,3.42096200376204e-11,0.17191181371717326,546048.0674332818,0.27240873104650953,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM460MH3-72 (1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,460.0,431.3,1.97388,,,72.0,11.66,49.88,11.13,41.34,0.00626142,-0.13053596,45.1,1.8375192263791524,11.660002996286071,1.8951575633868485e-11,0.25696447366146535,999999.8282219475,7.765485192889669,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM460MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,460.0,427.9,2.16,,,60.0,13.82,41.55,13.34,34.49,0.006343380000000001,-0.111354,46.0,1.548849140409859,13.820905432070253,3.086718412341486e-11,0.172891434193579,2638.9168205683345,8.069269078646935,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM460MH5-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,460.0,428.8,2.16,,,60.0,13.82,41.55,13.34,34.49,0.006523040000000001,-0.113847,45.2,1.5542215628802742,13.820004336538851,3.3902630165324796e-11,0.17199712551973748,548148.5448265015,6.472224354595405,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM525DMH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,525.0,490.5,2.58,,,72.0,13.39,49.08,12.95,40.58,0.006467370000000001,-0.1428228,44.6,1.8356924236996643,13.390002306543167,3.275385281658e-11,0.1722046826845162,999722.4294049988,0.17604724299045185,-0.35,N,2025.7.3,6/23/2025,2.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM525MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,525.0,487.8,2.58,,,72.0,13.39,49.08,12.95,40.58,0.006146010000000001,-0.13153440000000002,46.0,1.826964113031872,13.390002337356572,2.882626927966673e-11,0.17450678468653322,999727.8937564167,7.743695862626847,-0.352,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM525MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,525.0,488.8,2.58,,,72.0,13.39,49.08,12.95,40.58,0.0063200800000000005,-0.13447920000000002,45.2,1.840155549667211,13.39000253216883,3.494820582247632e-11,0.1710262037188111,903859.4549759597,7.007633522861875,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM530DMH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,530.0,495.2,2.58,,,72.0,13.46,49.23,13.02,40.73,0.006501180000000001,-0.14325929999999998,44.6,1.8411725746579848,13.460094367879732,3.285943657968494e-11,0.22059696651915,31464.512308972488,0.16022502412534442,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM530MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,530.0,492.5,2.58,,,72.0,13.46,49.23,13.02,40.73,0.006178140000000001,-0.1319364,46.0,1.8112003038239817,13.460005601399594,2.1112538600064097e-11,0.2255869946925566,542087.8556642988,5.013237828145693,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM530MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,530.0,493.6,2.58,,,72.0,13.46,49.23,13.02,40.73,0.006353120000000001,-0.1348902,45.2,1.8306469499642881,13.46000552038344,2.8179782525287862e-11,0.22234420813797018,542139.1732307498,5.114452892272001,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM535DMH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,535.0,500.0,2.58,,,72.0,13.54,49.38,13.1,40.88,0.00653982,-0.14369579999999998,44.6,1.8353590044484178,13.732263338927059,2.8387461783800863e-11,0.2175788116417283,999999.9871384862,-1.1712468906949904,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM535MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,535.0,497.3,2.58,,,72.0,13.54,49.38,13.1,40.88,0.00621486,-0.13233840000000002,46.0,1.8150651242017946,13.54000559408055,2.0718512794445093e-11,0.22302054473762759,539810.9666072174,4.802372606962307,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM535MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,535.0,498.3,2.58,,,72.0,13.54,49.38,13.1,40.88,0.00639088,-0.1353012,45.2,1.8527288291666675,13.540002459278666,3.602046795793672e-11,0.16421397902654356,903591.8535018096,7.1729529418984725,-0.356,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM540DMH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,540.0,504.8,2.58,,,72.0,13.63,49.53,13.17,41.03,0.00658329,-0.1441323,44.6,1.8524755950888143,13.630005824412022,3.33178477077767e-11,0.2149008986356632,502911.5260163392,0.1704435217060772,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM540MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,540.0,502.1,2.58,,,72.0,13.63,49.53,13.17,41.03,0.006256170000000001,-0.1327404,46.0,1.8441521317791292,13.63011114992173,2.952668766926221e-11,0.21627352140761355,26521.036455777456,7.798650131659564,-0.352,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM540MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,540.0,503.1,2.58,,,72.0,13.63,49.53,13.17,41.03,0.00643336,-0.1357122,45.2,1.8573243243447017,13.630066296593759,3.5723988948917354e-11,0.21410557781204495,44018.314012240306,7.044191774422625,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM545DMH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,545.0,509.6,2.58,,,72.0,13.71,49.68,13.24,41.18,0.006621930000000001,-0.1445688,44.6,1.8581476553932945,13.71000290909341,3.354337965989147e-11,0.21217829888410172,999999.7256077877,0.177681445111119,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM545MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,545.0,506.9,2.58,,,72.0,13.71,49.68,13.24,41.18,0.006292890000000001,-0.13314240000000002,46.0,1.850115682379287,13.710002339924827,2.986741860839364e-11,0.17062918536598073,999776.5083223855,7.847261753321671,-0.352,N,2025.7.3,6/23/2025,2.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM545MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,545.0,507.9,2.58,,,72.0,13.71,49.68,13.24,41.18,0.0064711199999999995,-0.13612320000000003,45.2,1.839881891083996,13.710005542794223,2.5723551532259712e-11,0.21517444284328416,532239.8495781681,4.184910112292487,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM550DMH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,550.0,514.4,2.58,,,72.0,13.8,49.83,13.31,41.31,0.006665400000000001,-0.1450053,44.6,1.8629093098126417,13.800005530601439,3.335471644870621e-11,0.21118231915204133,526955.7880307557,0.07894328863880692,-0.35,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM550MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,550.0,511.7,2.58,,,72.0,13.8,49.83,13.31,41.31,0.006334200000000001,-0.1335444,46.0,1.854787709652858,13.800002415093001,2.9668266831344226e-11,0.17494625372379194,999687.2346214849,7.731746265079934,-0.352,N,2025.7.3,6/23/2025,2.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM550MH5-72(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,550.0,512.7,2.58,,,72.0,13.8,49.83,13.31,41.31,0.0065136000000000005,-0.13653420000000002,45.2,2.5974988084355473,13.800122806156251,2.8061743500269715e-12,3.0883060657539927,499493.5738799502,8.286182977551247,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Tangshan Haitai New Energy Technology Co Ltd HTM590DMH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,590.0,551.7,2.83,,,60.0,18.11,40.77,17.15,34.42,0.007171560000000001,-0.10070190000000001,45.3,1.4864813473330556,18.119770674097232,2.1940339239315115e-11,0.09762872205081773,180.9553924316127,11.770094105756801,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM590MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,590.0,554.1,2.24,,,60.0,18.11,40.77,17.15,34.42,0.0068818,-0.10029420000000001,45.6,1.499450816557904,18.119281284116514,2.7825390365426934e-11,0.09592766703805844,187.17776976300667,14.43134478070492,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM590MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,590.0,550.5,2.83,,,60.0,18.11,40.77,17.15,34.42,0.007298330000000001,-0.09662490000000001,45.4,1.499816121780735,18.119267674632415,2.8010586173181268e-11,0.09587983306171699,187.3591658181124,18.837218001703448,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM595DMH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,595.0,556.5,2.83,,,60.0,18.15,40.97,17.19,34.62,0.0071874,-0.1011959,45.3,1.4943445774049744,18.159526860804693,2.2221934684242078e-11,0.09583000218403356,182.56953517691073,11.865644985940488,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM595MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,595.0,559.0,2.24,,,60.0,18.15,40.97,17.19,34.62,0.0068969999999999995,-0.1007862,45.6,1.5073853288589143,18.159044790066623,2.818130978917682e-11,0.0941225352140089,188.87381716377487,14.528568940157102,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM595MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,595.0,555.3,2.83,,,60.0,18.15,40.97,17.19,34.62,0.00731445,-0.0970989,45.4,1.5077467116158447,18.159031603168515,2.83658032566267e-11,0.09407529635286051,189.05465712093198,18.937198270735806,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM600DMH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,600.0,561.3,2.83,,,60.0,18.2,41.17,17.24,34.82,0.0072072,-0.1016899,45.3,1.5021849268270064,18.209263745116097,2.2508356450276877e-11,0.09399083456107783,184.65892320757675,11.956655389442197,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM600MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,600.0,563.8,2.24,,,60.0,18.2,41.17,17.24,34.82,0.006915999999999999,-0.1012782,45.6,1.5152966434780615,18.208789167451876,2.8543374621755275e-11,0.09227803490948405,191.08297294768803,14.621170655201775,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM600MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,600.0,560.1,2.83,,,60.0,18.2,41.17,17.24,34.82,0.0073346,-0.0975729,45.4,1.515654300837157,18.208776391585932,2.8727270376151254e-11,0.09223139056107955,191.26440554605782,19.032423534396923,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM605DMH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,605.0,566.1,2.83,,,60.0,18.25,41.37,17.28,35.02,0.007227000000000001,-0.1021839,45.3,1.5104410557330126,18.259517664854467,2.2952951243724292e-11,0.09211515343684476,176.6296233665425,12.11206585740045,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM605MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,605.0,568.7,2.24,,,60.0,18.25,41.37,17.28,35.02,0.006934999999999999,-0.10177019999999999,45.6,1.5236297736303601,18.2590410567831,2.910532810824175e-11,0.09039504342091807,182.46866404893157,14.779364215442449,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM605MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,605.0,564.9,2.83,,,60.0,18.25,41.37,17.28,35.02,0.00735475,-0.09804689999999998,45.4,1.5239796877837644,18.259028577199526,2.9287649108373846e-11,0.09034948192746776,182.62878211035354,19.19508223397449,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM610DMH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,610.0,570.9,2.83,,,60.0,18.31,41.57,17.32,35.22,0.00725076,-0.1026779,45.3,1.5190970148117868,18.32022987595875,2.3568804392038516e-11,0.09015161576208035,161.3583682477085,12.328471527885872,-0.336,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM610MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,610.0,573.6,2.24,,,60.0,18.31,41.57,17.32,35.22,0.006957799999999999,-0.1022622,45.6,1.532368561793861,18.31974189619995,2.988373096187968e-11,0.0884232542071885,166.19247019478652,14.999675358054924,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM610MH8-60(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,610.0,569.7,2.83,,,60.0,18.31,41.57,17.32,35.22,0.00737893,-0.0985209,45.4,1.5327068010054004,18.319729619446548,3.006346728498693e-11,0.0883792776490289,166.31941177304284,19.421594281056535,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM645DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,645.0,601.3,3.11,,,66.0,18.04,44.75,17.12,37.68,0.0068552,-0.110085,45.6,1.6420247681025009,18.047557292103185,2.6097059474990557e-11,0.11256945768026798,268.7143762565044,13.862203310493276,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM645MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,645.0,601.3,3.11,,,66.0,18.04,44.75,17.12,37.68,0.0068552,-0.110085,45.6,1.6420247681025009,18.047557292103185,2.6097059474990557e-11,0.11256945768026798,268.7143762565044,13.862203310493276,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM645MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,645.0,601.8,3.11,,,66.0,18.04,44.75,17.12,37.68,0.007270120000000001,-0.1060575,45.4,1.6424619122879838,18.047542925802215,2.6287360543466766e-11,0.1125122533060429,269.08935871224753,18.25190087558706,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM650DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,650.0,606.1,3.11,,,66.0,18.1,44.95,17.16,37.88,0.006878,-0.110577,45.6,1.6508122801261296,18.108458233637442,2.678465245232509e-11,0.11051520968262933,236.4944498641423,14.077046376906804,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM650MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,650.0,606.1,3.11,,,66.0,18.1,44.95,17.16,37.88,0.006878,-0.110577,45.6,1.6508122801261296,18.108458233637442,2.678465245232509e-11,0.11051520968262933,236.4944498641423,14.077046376906804,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM650MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,650.0,606.5,3.11,,,66.0,18.1,44.95,17.16,37.88,0.007294300000000001,-0.1065315,45.4,1.651237748599582,18.108443992300657,2.6973550524695958e-11,0.11045961888939371,236.77415205308165,18.4728565375073,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM655DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,655.0,610.9,3.11,,,66.0,18.16,45.15,17.21,38.08,0.0069008,-0.111069,45.6,1.6591468598688675,18.16876265576022,2.7298525260703357e-11,0.10851701405359888,224.89403248677996,14.224597194802394,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM655MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,655.0,610.9,3.11,,,66.0,18.16,45.15,17.21,38.08,0.0069008,-0.111069,45.6,1.6591468598688675,18.16876265576022,2.7298525260703357e-11,0.10851701405359888,224.89403248677996,14.224597194802394,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM655MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,655.0,611.3,3.11,,,66.0,18.16,45.15,17.21,38.08,0.007318480000000001,-0.1070055,45.4,1.6595647572711665,18.168748680808886,2.7486544907673356e-11,0.10846253233444869,225.14018333853878,18.624606910815388,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM660DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,660.0,615.7,3.11,,,66.0,18.19,45.35,17.25,38.28,0.0069122,-0.11156100000000001,45.6,1.6666340044025223,18.198033718623478,2.7424647988997233e-11,0.10679670752183901,241.80982876617898,14.249010087834145,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM660MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,660.0,615.7,3.11,,,66.0,18.19,45.35,17.25,38.28,0.0069122,-0.11156100000000001,45.6,1.6666340044025223,18.198033718623478,2.7424647988997233e-11,0.10679670752183901,241.80982876617898,14.249010087834145,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM660MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,660.0,616.1,3.11,,,66.0,18.19,45.35,17.25,38.28,0.007330570000000001,-0.10747949999999999,45.4,1.6670521960408686,18.19802025912308,2.7612802440665874e-11,0.10674229040627274,242.09221262214015,18.649721991229782,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM665DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,665.0,620.5,3.11,,,66.0,18.25,45.55,17.29,38.48,0.006934999999999999,-0.11205299999999999,45.6,1.6754321686232534,18.258855767568022,2.813556280991021e-11,0.10476898527350459,215.90833088338192,14.460867345862129,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM665MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,665.0,620.5,3.11,,,66.0,18.25,45.55,17.29,38.48,0.006934999999999999,-0.11205299999999999,45.6,1.6754321686232534,18.258855767568022,2.813556280991021e-11,0.10476898527350459,215.90833088338192,14.460867345862129,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM665MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,665.0,620.9,3.11,,,66.0,18.25,45.55,17.29,38.48,0.00735475,-0.10795349999999998,45.4,1.675838389307536,18.25884244329178,2.8321901593929704e-11,0.10471620653318423,216.12474290644127,18.86758096679966,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM670DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,670.0,625.3,3.11,,,66.0,18.31,45.75,17.33,38.68,0.006957799999999999,-0.112545,45.6,1.6842372119966684,18.319636785070298,2.886090650620409e-11,0.10274899166755498,195.22424081147952,14.671882676362502,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM670MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,670.0,625.3,3.11,,,66.0,18.31,45.75,17.33,38.68,0.006957799999999999,-0.112545,45.6,1.6842372119966684,18.319636785070298,2.886090650620409e-11,0.10274899166755498,195.22424081147952,14.671882676362502,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM670MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,670.0,625.7,3.11,,,66.0,18.31,45.75,17.33,38.68,0.00737893,-0.1084275,45.4,1.6846312974030422,18.319623615015608,2.90451884889391e-11,0.10269787136024543,195.39414588067535,19.084547721726107,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM675DMH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,675.0,630.1,3.11,,,66.0,18.36,45.95,17.37,38.88,0.006976799999999999,-0.113037,45.6,1.6926057609406333,18.369891371052766,2.939396373101862e-11,0.10084303710121131,187.18114629666542,14.819092863482991,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM675MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,675.0,630.1,3.11,,,66.0,18.36,45.95,17.37,38.88,0.006976799999999999,-0.113037,45.6,1.6926057609406333,18.369891371052766,2.939396373101862e-11,0.10084303710121131,187.18114629666542,14.819092863482991,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tangshan Haitai New Energy Technology Co Ltd HTM675MH8-66(1500),Tangshan Haitai New Energy Technology Co Ltd,Mono-c-Si,0,675.0,630.5,3.11,,,66.0,18.36,45.95,17.37,38.88,0.00739908,-0.1089015,45.4,1.692991722107546,18.369878471275836,2.957675138399405e-11,0.1007930408586534,187.3326538873297,19.23594428645383,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tata Power Renewables TP515HG10B,Tata Power Renewables,Mono-c-Si,1,515.0,479.1,2.56,,,48.0,13.08,49.05,12.39,41.55,0.004290240000000001,-0.12924675,45.85,1.8065349880079051,13.086139808912522,2.0886561772301228e-11,0.1469736513835382,313.1067108056623,7.193601798735063,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP520HG10B,Tata Power Renewables,Mono-c-Si,1,520.0,483.9,2.56,,,48.0,13.09,49.15,12.47,41.7,0.00429352,-0.12951025,45.85,1.8066564920433956,13.092604520570028,1.9942318787003818e-11,0.14199143729371325,713.6315081933402,6.760465974551847,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP525HG10B,Tata Power Renewables,Mono-c-Si,1,525.0,488.7,2.56,,,48.0,13.12,49.2,12.5,42.0,0.00430336,-0.129642,45.85,1.8139232851814406,13.122338499238426,2.1674641518031056e-11,0.1182881606692464,663.6481616103015,7.464446386413738,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP530HG10B,Tata Power Renewables,Mono-c-Si,1,530.0,493.5,2.56,,,48.0,13.13,49.3,12.56,42.2,0.0043066400000000005,-0.1299055,45.85,1.816508392673012,13.130399083167882,2.14327845823229e-11,0.10871775973538406,3576.8602156957895,7.342134435608268,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP535HG10B,Tata Power Renewables,Mono-c-Si,1,535.0,498.2,2.56,,,48.0,13.2,49.4,12.63,42.35,0.0043296,-0.130169,45.85,1.8213491389158791,13.20032382864678,2.192474050369975e-11,0.10258824639046576,4181.733206058556,7.492549491583157,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP540HG10B,Tata Power Renewables,Mono-c-Si,1,540.0,503.0,2.56,,,48.0,13.23,49.5,12.72,42.45,0.00433944,-0.1304325,45.85,1.8278237733695422,13.23000114284472,2.292250241379511e-11,0.0863811650411305,999998.280189056,7.856837832379707,-0.3468,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP560LG10B,Tata Power Renewables,Mono-c-Si,1,560.0,521.6,2.76,,,52.0,13.02,53.25,12.4,45.17,0.00269514,-0.138663,45.85,1.9201325204580582,13.023343957921135,1.169087136985873e-11,0.16220084830258275,631.5435509335373,3.672769220898025,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP565LG10B,Tata Power Renewables,Mono-c-Si,1,565.0,526.4,2.76,,,52.0,13.03,53.3,12.42,45.5,0.00269721,-0.1387932,45.85,1.9271061129020657,13.032594511754318,1.260906692556381e-11,0.13597299647854438,682.8753665358037,4.301906413289448,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP570LG10B,Tata Power Renewables,Mono-c-Si,1,570.0,531.2,2.76,,,52.0,13.04,53.41,12.47,45.71,0.0026992799999999996,-0.13907964,45.85,1.9304727712031482,13.040925186822374,1.2553619541361076e-11,0.12611800659364575,1777.5639821373093,4.243276982803429,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP575LG10B,Tata Power Renewables,Mono-c-Si,1,575.0,535.9,2.76,,,52.0,13.1,53.52,12.54,45.87,0.0027117,-0.13936608,45.85,1.9330649220158869,13.100001612057529,1.239169717945702e-11,0.12031532451999329,977712.6591736821,4.085503435108571,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP580LG10B,Tata Power Renewables,Mono-c-Si,1,580.0,540.7,2.76,,,52.0,13.12,53.63,12.62,45.97,0.0027158399999999997,-0.13965252,45.85,1.9411257828643784,13.120005570181121,1.3155573533995015e-11,0.1043656945190974,245823.46386672033,4.578419913752378,-0.3425,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP585LG10B,Tata Power Renewables,Mono-c-Si,1,585.0,545.5,2.76,,,52.0,13.2,53.73,12.69,46.1,0.0027324000000000003,-0.13991292000000002,45.85,1.9450666614511976,13.20000135375703,1.3296516307695713e-11,0.10255621083060658,999998.7868781957,4.617154865520977,-0.3425,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP590LG10B,Tata Power Renewables,Mono-c-Si,1,590.0,550.3,2.76,,,52.0,13.29,53.9,12.78,46.18,0.00275103,-0.14035560000000002,45.85,1.9502758996693415,13.290001415575011,1.3209201779880103e-11,0.10651304743966895,999998.2333610564,4.503788862480697,-0.3425,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP590VG12R16NB,Tata Power Renewables,Mono-c-Si,1,590.0,558.2,2.7,,,22.0,15.7,47.78,14.86,39.73,0.007096399999999999,-0.1086995,45.56,1.6233737711525729,15.714923454404468,2.555270076517016e-12,0.19486208328340238,205.0017795854953,2.8980948256689176,-0.2811,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP595LG10B,Tata Power Renewables,Mono-c-Si,1,595.0,555.1,2.76,,,52.0,13.37,54.01,12.86,46.28,0.0027675899999999995,-0.14064204000000002,45.85,1.9545527342461706,13.370001398945211,1.3344578998124314e-11,0.1046315456540858,999994.682009895,4.539311406455804,-0.3425,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP595VG12R16NB,Tata Power Renewables,Mono-c-Si,1,595.0,563.0,2.7,,,22.0,15.76,47.98,14.91,39.93,0.0071235199999999995,-0.1091545,45.56,1.6311284644969961,15.775406134465443,2.6082464541495635e-12,0.1923616694549605,196.780050360985,3.0436709313518726,-0.2811,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP600LG10B,Tata Power Renewables,Mono-c-Si,1,600.0,559.9,2.76,,,52.0,13.45,54.12,12.93,46.41,0.00278415,-0.14092848000000002,45.85,1.9373446503029024,13.450003133483557,9.922942841821205e-12,0.11955578095923367,513177.04709414137,2.00751704403363,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP600VG12R16NB,Tata Power Renewables,Mono-c-Si,1,600.0,567.8,2.7,,,22.0,15.82,48.18,14.96,40.13,0.00715064,-0.1096095,45.56,1.6388847138729152,15.835870702570558,2.661933059510819e-12,0.1898776643307106,189.27105709529448,3.1882713211835707,-0.2811,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP605VG12R16NB,Tata Power Renewables,Mono-c-Si,1,605.0,572.7,2.7,,,22.0,15.88,48.38,15.01,40.33,0.007177760000000001,-0.11006450000000002,45.56,1.6466425763895765,15.896317420844452,2.7163367039110814e-12,0.18740989398236987,182.38600066322405,3.3319169212874895,-0.2811,N,2025.7.3,6/23/2025,2.0,first_pass +Tata Power Renewables TP610VG12R16NB,Tata Power Renewables,Mono-c-Si,1,610.0,577.5,2.7,,,22.0,15.94,48.58,15.06,40.53,0.007204879999999999,-0.1105195,45.56,1.6544019634200036,15.956746548662943,2.7714571836419173e-12,0.18495820896180462,176.05023633349109,3.4746059379833683,-0.2811,N,2025.7.3,6/23/2025,4.0,first_pass +Tata Power Renewables TP615VG12R16NB,Tata Power Renewables,Mono-c-Si,1,615.0,582.4,2.7,,,22.0,15.99,48.78,15.11,40.73,0.0072274800000000005,-0.1109745,45.56,1.661704394927646,16.006419474065922,2.8047881620867146e-12,0.18265427931527212,177.87670370797844,3.5499922905757915,-0.2811,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR24S3-2,Tesla Inc,Multi-c-Si,0,23.75,20.5,0.24,,,6.0,8.35,3.8,7.8,3.04,0.003991300000000001,-0.012342399999999998,48.95,0.165780321303286,8.358594950578283,9.154610863439859e-10,0.03627761199120065,35.243742901312025,21.944414873444206,-0.5089,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR24T3-2,Tesla Inc,Multi-c-Si,0,23.75,20.5,0.24,,,6.0,8.35,3.8,7.8,3.04,0.003991300000000001,-0.012342399999999998,48.95,0.165780321303286,8.358594950578283,9.154610863439859e-10,0.03627761199120065,35.243742901312025,21.944414873444206,-0.5089,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR25S3,Tesla Inc,Mono-c-Si,0,25.0,22.3,0.2363,,,6.0,7.7,4.3,7.2,3.5,0.002002,-0.0117433,49.88,0.16327125397330267,7.712957824497199,2.751976398589692e-11,0.04220902349265234,25.082102734599538,10.476340927514629,-0.3899,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR25T3,Tesla Inc,Mono-c-Si,0,25.0,21.9,0.23672,,,6.0,7.7,4.3,7.2,3.5,0.001694,-0.0125001,53.8,0.16132209420430943,7.713519375842209,2.0007533647169343e-11,0.042793991701887954,24.373443213874523,1.191342139529026,-0.3816,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR60T1,Tesla Inc,Multi-c-Si,0,58.47,52.1,0.49,,,21.0,5.65,13.34,5.32,10.99,0.0026555,-0.039886599999999994,49.98,0.5231823383245405,5.654502827806466,4.711038542148532e-11,0.14362606027503788,180.21725612922606,7.681894977093699,-0.395,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR72T1,Tesla Inc,Mono-c-Si,0,72.0,65.4,0.49,,,21.0,6.8,14.2,6.3,11.3,0.002516,-0.037772,48.16,0.5295078145163497,6.821971343326814,1.489230272563067e-11,0.20738098823402631,64.18318223719378,8.934463326900127,-0.372,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR72T2,Tesla Inc,Mono-c-Si,0,72.0,65.4,0.4902,,,21.0,6.8,14.2,6.3,11.3,0.002516,-0.037772,48.16,0.5295078145163497,6.821971343326814,1.489230272563067e-11,0.20738098823402631,64.18318223719378,8.934463326900127,-0.372,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR72T3R,Tesla Inc,Mono-c-Si,0,72.0,65.4,0.49,,,21.0,6.8,14.2,6.3,11.3,0.002516,-0.037772,48.16,0.5295078145163497,6.821971343326814,1.489230272563067e-11,0.20738098823402631,64.18318223719378,8.934463326900127,-0.372,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc SR73T3R,Tesla Inc,Mono-c-Si,0,73.0,66.0,0.45,,,21.0,6.6,14.2,6.3,11.6,0.002706,-0.038482,50.53,0.5278806808983255,6.600001014468584,1.370924499523299e-11,0.15369509989195904,999999.2425784784,6.299307277808625,-0.364,Y,2025.7.3,6/23/2025,2.0,first_pass +Tesla Inc SR75T3R,Tesla Inc,Mono-c-Si,0,75.0,67.9,0.45,,,21.0,6.7,14.2,6.4,11.7,0.0027470000000000003,-0.038482,50.53,0.5299828433682403,6.700000893903903,1.548398864708352e-11,0.1334079950999275,999998.2719249867,7.220763193710405,-0.364,Y,2025.7.3,6/23/2025,2.0,first_pass +Tesla Inc SR86T3R,Tesla Inc,Mono-c-Si,0,86.0,77.3,0.48,,,39.0,4.06,26.6,3.79,22.51,0.0016646,-0.069426,55.18,0.978543123992234,4.064878448837462,6.171445349100556e-12,0.26428300099726415,219.94470425017957,7.752250978709238,-0.333,Y,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc T395H,Tesla Inc,Mono-c-Si,0,395.0,366.7,1.92,,,66.0,11.1,45.27,10.71,36.88,0.0045954,-0.12200265000000002,45.7,1.6852113660812678,11.100003098338902,2.3923540269877912e-11,0.25647184094454595,918858.0722418058,7.20891591892345,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Tesla Inc T400H,Tesla Inc,Mono-c-Si,0,400.0,371.5,1.92,,,66.0,11.14,45.3,10.77,37.13,0.004611960000000001,-0.1220835,45.7,1.692181308159234,11.140002491752808,2.6347633211426187e-11,0.2236125731742324,999751.0080527395,8.01771681855419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Tesla Inc T405H,Tesla Inc,Mono-c-Si,0,405.0,376.3,1.92,,,66.0,11.17,45.34,10.83,37.39,0.00462438,-0.12219130000000002,45.7,1.700226666247105,11.170002076239296,2.928912296017543e-11,0.18583178255755423,999793.6591647506,8.92220527352419,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Tesla Inc TSP-405,Tesla Inc,Mono-c-Si,0,405.0,380.9,2.03,,,120.0,12.74,40.87,11.86,34.15,0.005733,-0.10667070000000001,42.84,1.5230560034722853,12.760759820024461,2.741968340559851e-11,0.16608374238642828,101.9231806328124,10.779082356235833,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc T410H,Tesla Inc,Mono-c-Si,0,410.0,381.0,1.92,,,66.0,11.2,45.37,10.89,37.64,0.004636799999999999,-0.12227215000000001,45.7,1.707878158178979,11.2000016494607,3.251833520854675e-11,0.14724291252741192,999825.8285556837,9.822735287637995,-0.3621,N,2025.7.3,6/23/2025,2.0,first_pass +Tesla Inc TSP-410,Tesla Inc,Mono-c-Si,0,410.0,385.7,2.03,,,120.0,12.83,40.9,11.9,34.2,0.0057735,-0.106749,42.84,1.5275547179652003,12.85347244274181,2.917407468684854e-11,0.16226269878200272,88.69253429736591,11.289906406799796,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc TSP-415,Tesla Inc,Mono-c-Si,0,415.0,390.6,2.03,,,120.0,12.93,40.92,12.12,34.24,0.0058185,-0.10680120000000001,42.84,1.5208284077161172,12.945186163332982,2.609816771353342e-11,0.15990337691968395,136.1470062349472,10.174647323070609,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +Tesla Inc T420S,Tesla Inc,Mono-c-Si,0,420.0,392.2,2.111,,,24.0,11.16,48.5,10.27,40.9,0.004464,-0.1261,45.65,1.787416508917947,11.182792069624243,1.7522948370656486e-11,0.189955853841543,93.01074310175635,8.530840576340792,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc TSP-420,Tesla Inc,Mono-c-Si,0,420.0,395.4,2.03,,,120.0,13.03,40.95,12.25,34.29,0.0058635,-0.10687950000000002,42.84,1.5202943899193695,13.042802325944153,2.563109242736536e-11,0.15672859240750137,159.51582389703202,9.931976482221668,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc T425S,Tesla Inc,Mono-c-Si,0,425.0,397.0,2.111,,,24.0,11.24,48.65,10.36,41.05,0.004496,-0.12649,45.65,1.79202047945929,11.261778569778057,1.7435036162130706e-11,0.1868674348864445,96.44297085032116,8.417106026034677,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc TSP-425,Tesla Inc,Mono-c-Si,0,425.0,400.2,2.03,,,120.0,13.12,40.98,12.38,34.33,0.005903999999999999,-0.1069578,42.84,1.5190239979988915,13.129923652139093,2.4845835662748044e-11,0.15471861795010977,204.55254311149613,9.57768527229421,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc T430S,Tesla Inc,Mono-c-Si,0,430.0,401.8,2.111,,,24.0,11.32,48.8,10.44,41.2,0.004528000000000001,-0.12688,45.65,1.7975201486834214,11.341312178035356,1.7563908745446753e-11,0.18365006097671752,97.54604576504698,8.417113327143202,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Tesla Inc TSP-430,Tesla Inc,Mono-c-Si,0,430.0,405.0,2.03,,,120.0,13.2,41.01,12.49,34.43,0.00594,-0.1070361,42.84,1.5197657856390163,13.207558754937645,2.490930702842744e-11,0.14725922376121556,257.1616339401323,9.534727375542333,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB54(400),Thornova Solar,Mono-c-Si,1,400.0,372.2,1.95,,,54.0,13.39,37.2,12.74,31.4,0.007632300000000002,-0.09672000000000001,45.9,1.3988213809916061,13.392794992638784,3.759219364690049e-11,0.11343233083798697,543.4214530500334,13.371004738328592,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG54(400),Thornova Solar,Mono-c-Si,1,400.0,376.1,1.95,,,54.0,13.39,37.18,12.74,31.42,0.004017000000000001,-0.08692684,46.05,1.2734377027195312,13.396152665856214,2.7724885923925342e-12,0.13233584967203207,288.00150558952043,2.333894211575433,-0.2967,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB54(400),Thornova Solar,Mono-c-Si,0,400.0,376.9,1.94,,,54.0,13.39,37.18,12.74,31.42,0.005650580000000001,-0.08796788000000001,43.4,1.3417500469704398,13.394186889535083,1.2286606706132476e-11,0.1201054332858543,384.10656638236185,14.049999913614295,-0.3284,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BB54(405),Thornova Solar,Mono-c-Si,1,405.0,376.9,1.95,,,54.0,13.44,37.3,12.84,31.6,0.0076608,-0.09698,45.9,1.4023881415602926,13.440238653099167,3.776228365795236e-11,0.10341265267208843,5823.793737641172,13.360866269093359,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG54(405),Thornova Solar,Mono-c-Si,1,405.0,380.9,1.95,,,54.0,13.44,37.33,12.84,31.55,0.004032,-0.08727754,46.05,1.2722584590159678,13.440003946419974,2.4296039746095323e-12,0.13300266339006472,452957.15922996495,1.152763106261169,-0.2967,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB54(405),Thornova Solar,Mono-c-Si,0,405.0,381.8,1.94,,,54.0,13.44,37.33,12.84,31.55,0.00567168,-0.08832277999999999,43.4,1.3227992405851972,13.440003633449392,7.45431439154143e-12,0.12401962499744888,458746.5564755684,9.427616380734626,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB54(410),Thornova Solar,Mono-c-Si,1,410.0,381.7,1.95,,,54.0,13.59,37.7,12.88,31.8,0.0077463,-0.09802000000000002,45.9,1.3779203355531326,13.590048420636709,1.781793543187403e-11,0.12195132406755596,34227.553110877314,6.552336277328883,-0.348,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG54(410),Thornova Solar,Mono-c-Si,1,410.0,387.2,1.94,,,54.0,13.59,37.68,12.88,31.84,0.0058301099999999995,-0.09224064,43.4,1.3399053386041968,13.590003273194258,8.324698240147513e-12,0.12356090650991922,513016.72637353546,6.706666748578436,-0.3195,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB54(410),Thornova Solar,Mono-c-Si,0,410.0,386.6,1.94,,,54.0,13.59,37.68,12.88,31.84,0.00573498,-0.08915088,43.4,1.3091724120878963,13.598721628055566,4.244379511567001e-12,0.1291928685251956,201.30772310902043,4.440126127743351,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB54(415),Thornova Solar,Mono-c-Si,1,415.0,392.4,1.94,,,54.0,13.72,37.79,13.01,31.94,0.006297480000000001,-0.09254771,43.4,1.3513774113260717,13.727130357619224,9.722472272350009e-12,0.12099940640585494,232.8230854939505,7.829511896030213,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG54(415),Thornova Solar,Mono-c-Si,1,415.0,392.1,1.94,,,54.0,13.72,37.79,13.01,31.94,0.0058858800000000005,-0.09250992,43.4,1.355323433621009,13.727008369517502,1.0548521357890343e-11,0.12031120039084332,235.52834527638652,8.63568252568472,-0.3195,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB54(415),Thornova Solar,Mono-c-Si,0,415.0,391.4,1.94,,,54.0,13.72,37.79,13.0,31.94,0.005789840000000001,-0.08941114,43.4,1.3664878026114553,13.72722750869327,1.3239939723184795e-11,0.11838511751833439,224.73080120246112,14.539807152675813,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB54(420),Thornova Solar,Mono-c-Si,1,420.0,397.3,1.94,,,54.0,13.8,38.0,13.09,32.11,0.006334200000000001,-0.093062,43.4,1.3585337267657875,13.806967786037017,9.712090069945657e-12,0.12164508690455689,240.92332863337094,7.767314942946523,-0.3143,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(420),Thornova Solar,Mono-c-Si,1,420.0,398.4,1.94,,,54.0,13.4,38.51,12.76,32.92,0.005762,-0.08653197,43.4,1.346161396733809,13.40413038798944,5.00488483267461e-12,0.09992848777789104,324.1927254909253,11.609405120170658,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG54(420),Thornova Solar,Mono-c-Si,1,420.0,396.9,1.94,,,54.0,13.8,38.0,13.09,32.11,0.0059202000000000005,-0.093024,43.4,1.3383595794459642,13.807598479101882,6.366760510988005e-12,0.12515263497681303,227.29632382155853,4.192441153236553,-0.3195,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(420),Thornova Solar,Mono-c-Si,1,420.0,398.2,1.94,,,54.0,13.56,38.4,12.93,32.49,0.006495239999999999,-0.08378880000000001,43.4,1.3425971872198874,13.563723085477838,5.108908979745355e-12,0.12672751367949955,461.55939829405224,14.958772873261088,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB54(420),Thornova Solar,Mono-c-Si,0,420.0,396.3,1.94,,,54.0,13.8,38.0,13.09,32.11,0.005823600000000001,-0.089908,43.4,1.3732312942367608,13.806521353849469,1.3107999683012286e-11,0.11910171696931758,252.03413413252628,14.386735176958936,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(420),Thornova Solar,Mono-c-Si,0,420.0,399.1,1.94,,,54.0,13.4,38.51,12.76,32.92,0.0060702,-0.08899661,43.1,1.342599824067645,13.404212012041217,4.6386090224371945e-12,0.10057304637628543,319.9608195430139,7.7890421961848295,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(425),Thornova Solar,Mono-c-Si,1,425.0,403.2,1.94,,,54.0,13.48,38.64,12.85,33.07,0.005796399999999999,-0.08682408000000001,43.4,1.3507805632085756,13.483475664209788,5.048574552833484e-12,0.09636120572606514,373.72685586369334,11.629500925294003,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG54(425),Thornova Solar,Mono-c-Si,1,425.0,401.7,1.94,,,54.0,13.88,38.21,13.17,32.28,0.0059545200000000005,-0.09353808,43.4,1.3696768431197555,13.886680707826649,1.0526633793235983e-11,0.12159630164005097,252.63141530022415,8.51138933769453,-0.3195,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(425),Thornova Solar,Mono-c-Si,1,425.0,403.1,1.94,,,54.0,13.64,38.59,13.01,32.67,0.006533560000000001,-0.08420338000000001,43.4,1.3494332411791505,13.643517738567029,5.161564462807714e-12,0.12495121352036086,484.4972210676288,14.998917972071917,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(425),Thornova Solar,Mono-c-Si,0,425.0,404.0,1.94,,,54.0,13.48,38.64,12.85,33.07,0.00610644,-0.08929704000000001,43.1,1.3472081950172998,13.48355221567029,4.679262779686043e-12,0.09700355224462139,368.110500398094,7.808835635193048,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(430),Thornova Solar,Mono-c-Si,1,430.0,408.1,1.94,,,54.0,13.57,38.77,12.95,33.2,0.0058351,-0.08711619000000001,43.4,1.355005534349577,13.572874555055304,5.0543201749903565e-12,0.09452638111074255,446.2335811219075,11.573441635116588,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(430),Thornova Solar,Mono-c-Si,1,430.0,407.9,1.94,,,54.0,13.72,38.78,13.09,32.85,0.00657188,-0.08461796,43.4,1.3562693109908932,13.72331723070522,5.214352416488023e-12,0.12319673643305946,509.5392458810274,15.038669068326167,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(430),Thornova Solar,Mono-c-Si,0,430.0,408.9,1.94,,,54.0,13.57,38.77,12.95,33.2,0.006147210000000001,-0.08959747000000001,43.1,1.3514208944766926,13.57294693817709,4.684393728258507e-12,0.09516604470370794,438.2187791217976,7.75430853716873,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB60(435),Thornova Solar,Mono-c-Si,1,435.0,410.3,2.14,,,60.0,13.32,40.99,12.73,34.18,0.00551448,-0.09513779000000001,43.4,1.440731473613972,13.320005255645448,5.8676588900787875e-12,0.17927951209000675,454371.2937852086,9.487428744305664,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(435),Thornova Solar,Mono-c-Si,1,435.0,412.9,1.94,,,54.0,13.65,38.9,13.05,33.34,0.0058695,-0.08740830000000001,43.4,1.3589751936532604,13.65189581760464,5.033310415444831e-12,0.09200025637725218,662.4073457763834,11.472299393087964,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT48(435)-G12R,Thornova Solar,Mono-c-Si,1,435.0,413.3,2.0,,,48.0,15.9,34.49,14.73,29.54,0.007409400000000001,-0.09488199000000001,43.2,1.2339411193119563,15.920054787121407,1.1086203890133131e-11,0.06673440492905501,52.90891559929504,-4.115565668984859,-0.2935,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(435),Thornova Solar,Mono-c-Si,1,435.0,412.8,1.94,,,54.0,13.8,38.97,13.17,33.03,0.0066102,-0.08503254,43.4,1.3631053619312365,13.803121478176632,5.267267919018281e-12,0.12146368300860888,536.988803849946,15.078070810604142,-0.3009,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-SB60(435),Thornova Solar,Mono-c-Si,0,435.0,409.9,2.14,,,60.0,13.32,40.99,12.73,34.18,0.005621040000000001,-0.09698234000000001,43.3,1.4537539932539318,13.320043640844935,7.57055839024285e-12,0.17698856312773212,54020.249209075824,9.64697117007889,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(435),Thornova Solar,Mono-c-Si,0,435.0,413.7,1.94,,,54.0,13.65,38.9,13.05,33.34,0.00618345,-0.0898979,43.1,1.3553781420542241,13.651960956981828,4.664581191125306e-12,0.09263733252127448,644.8380077986559,7.655928631460204,-0.2933,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BB60(440),Thornova Solar,Mono-c-Si,1,440.0,415.1,2.14,,,60.0,13.37,41.18,12.82,34.33,0.005535179999999999,-0.09557878,43.4,1.4214103404587233,13.37000455347189,3.5001412044661726e-12,0.1845143564426931,541776.8823745312,4.896327035735192,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(440),Thornova Solar,Mono-c-Si,1,440.0,417.8,1.94,,,54.0,13.73,39.03,13.15,33.48,0.0059039,-0.08770041,43.4,1.3629540445597268,13.73096445823998,5.0133918896689275e-12,0.08950984235189864,1274.259588091038,11.373475010554044,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG60(440),Thornova Solar,Mono-c-Si,1,440.0,408.0,2.16,,,60.0,13.37,41.18,12.8,34.39,0.005013749999999999,-0.11522164,46.16,1.5330604486333348,13.370003982940588,2.886780249882042e-11,0.16006173696554732,537309.6858995897,3.3063669540446874,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT48(440)-G12R,Thornova Solar,Mono-c-Si,1,440.0,418.2,2.0,,,48.0,15.95,34.67,14.81,29.72,0.0074327,-0.09537717000000001,43.2,1.2394894253433548,15.968347964619454,1.0928134353042967e-11,0.06514310643686261,56.62930848354281,-4.261277653189248,-0.2935,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(440),Thornova Solar,Mono-c-Si,1,440.0,417.7,1.94,,,54.0,13.88,39.16,13.25,33.21,0.00664852,-0.08544711999999999,43.4,1.3699414963497527,13.882930395384056,5.320320237355879e-12,0.11975166282461065,567.211202296767,15.117012115356637,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB60(440),Thornova Solar,Mono-c-Si,0,440.0,414.8,2.14,,,60.0,13.37,41.18,12.82,34.33,0.0056421399999999995,-0.09743188,43.3,1.4335079004901279,13.370004500748088,4.469583640946862e-12,0.18238956675375423,541812.0071415033,4.972670763848432,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(440),Thornova Solar,Mono-c-Si,0,440.0,418.6,1.94,,,54.0,13.73,39.03,13.15,33.48,0.00621969,-0.09019833000000001,43.1,1.3593445167447287,13.73102239305164,4.64578338305125e-12,0.09014437253339594,1210.5760530718783,7.559819774425794,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB60(445),Thornova Solar,Mono-c-Si,1,445.0,419.9,2.14,,,60.0,13.42,41.27,12.92,34.46,0.005555880000000001,-0.09578767000000002,43.4,1.4274173320021486,13.420004382828289,3.7262583247605245e-12,0.1787962984309436,547467.3163535603,5.407337715585005,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(445),Thornova Solar,Mono-c-Si,1,445.0,422.7,1.94,,,54.0,13.81,39.16,13.25,33.62,0.0059383,-0.08799251999999999,43.4,1.366941962248992,13.810079655385664,4.994534073583e-12,0.08705438557859406,15092.81321535956,11.276926159065953,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG60(445),Thornova Solar,Mono-c-Si,1,445.0,412.8,2.16,,,60.0,13.42,41.27,12.92,34.46,0.0050325000000000005,-0.11547346000000001,46.16,1.5399869912256328,13.420003911851653,3.084066900288972e-11,0.15945377433258803,547035.1826221192,3.8284650331068537,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT48(445)-G12R,Thornova Solar,Mono-c-Si,1,445.0,423.0,2.0,,,48.0,16.0,34.85,14.89,29.9,0.007456000000000001,-0.09587235000000001,43.2,1.2450394770593456,16.0167133348519,1.0774307133275416e-11,0.06356868192442977,60.855533658123164,-4.405250684094211,-0.2935,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(445),Thornova Solar,Mono-c-Si,1,445.0,422.5,1.94,,,54.0,13.96,39.35,13.33,33.39,0.0066868399999999995,-0.0858617,43.4,1.3767776110717644,13.96274390443467,5.3734974044888775e-12,0.11806029593625054,600.64837529296,15.155615159008441,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB60(445),Thornova Solar,Mono-c-Si,0,445.0,419.6,2.14,,,60.0,13.42,41.27,12.92,34.46,0.005663240000000001,-0.09764482000000002,43.3,1.43966837851643,13.42000433024981,4.765669762663184e-12,0.17666384261392645,547506.4499356266,5.4959249297383845,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(445),Thornova Solar,Mono-c-Si,0,445.0,423.4,1.94,,,54.0,13.81,39.16,13.25,33.62,0.00625593,-0.09049875999999998,43.1,1.3633198820755372,13.810130406343854,4.627970016053156e-12,0.08768642890691883,9285.869369041484,7.465893071201941,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB60(450),Thornova Solar,Mono-c-Si,1,450.0,424.7,2.14,,,60.0,13.47,41.46,13.01,34.62,0.00557658,-0.09622866000000001,43.4,1.4369426713609366,13.470004338317777,3.9691630542779755e-12,0.17812461514846456,553059.5390738138,5.925366324464752,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(450),Thornova Solar,Mono-c-Si,1,450.0,427.5,1.94,,,54.0,13.89,39.29,13.35,33.76,0.005972699999999999,-0.08828463000000002,43.4,1.3290278765623391,13.890002440520023,2.0121896408663726e-12,0.09193558789001245,523243.8181072896,3.1597103375867412,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG60(450),Thornova Solar,Mono-c-Si,1,450.0,417.6,2.16,,,60.0,13.47,41.46,13.01,34.62,0.00505125,-0.11600508000000001,46.16,1.5490941191305219,13.470003876696266,3.205495512170235e-11,0.1590291134971594,552577.4796561276,4.121646685590942,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT48(450)-G12R,Thornova Solar,Mono-c-Si,1,450.0,427.9,2.0,,,48.0,16.05,35.03,14.97,30.08,0.0074793,-0.09636753,43.2,1.2505912329630875,16.065149157112046,1.0624570643950355e-11,0.06201086723902619,65.69833639511438,-4.547516979514171,-0.2935,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(450),Thornova Solar,Mono-c-Si,1,450.0,427.4,1.94,,,54.0,14.04,39.54,13.41,33.57,0.00672516,-0.08627628,43.4,1.3836137397687656,14.042561925458772,5.426801621086462e-12,0.11638921075237409,637.8423398459169,15.193846645729584,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB60(450),Thornova Solar,Mono-c-Si,0,450.0,424.4,2.14,,,60.0,13.47,41.46,13.01,34.62,0.00568434,-0.09809436,43.3,1.4493734110289986,13.470004285776493,5.083581956071468e-12,0.1759808229405341,553102.408986631,6.025318015073531,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(450),Thornova Solar,Mono-c-Si,0,450.0,428.3,1.94,,,54.0,13.89,39.29,13.34,33.75,0.00629217,-0.09079919,43.1,1.3262767874195607,13.890228835706994,1.891599784465958e-12,0.09322688856468689,5658.738823714728,-0.2632074146921307,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB60(455),Thornova Solar,Mono-c-Si,1,455.0,429.6,2.14,,,60.0,13.54,41.65,13.09,34.78,0.00560556,-0.09666965,43.4,1.4434369876474362,13.540004356009623,3.9825544614397875e-12,0.17785979751195147,552852.5740278141,5.909513521052539,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(455),Thornova Solar,Mono-c-Si,1,455.0,432.4,1.94,,,54.0,13.97,39.42,13.45,33.9,0.0060071000000000005,-0.08857674000000001,43.4,1.333723378041951,13.97000238384495,2.0371958893422042e-12,0.08939708570675003,523892.6896080957,3.2165172329889113,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG60(455),Thornova Solar,Mono-c-Si,1,455.0,422.3,2.16,,,60.0,13.54,41.65,13.09,34.78,0.0050774999999999995,-0.1165367,46.16,1.5569928126410844,13.540002148265035,3.26675561023551e-11,0.15865328298213655,999999.0445858514,4.237339761720811,-0.358,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(455),Thornova Solar,Mono-c-Si,1,455.0,432.2,1.94,,,54.0,14.12,39.73,13.49,33.75,0.00676348,-0.08669086,43.4,1.39044988221688,14.122384381347805,5.480231594875108e-12,0.11473804479294991,679.4639642493041,15.231711703599531,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB60(455),Thornova Solar,Mono-c-Si,0,455.0,429.2,2.14,,,60.0,13.54,41.65,13.09,34.78,0.00571388,-0.0985439,43.3,1.4559174033567936,13.540004303310294,5.100160722650689e-12,0.17572144673488405,552895.2965115889,6.008517926500055,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(455),Thornova Solar,Mono-c-Si,0,455.0,433.2,1.94,,,54.0,13.97,39.42,13.44,33.88,0.0063284100000000005,-0.09109962,43.1,1.3495299279144923,13.970002356871115,2.8799042230606414e-12,0.0882646890699287,523176.6597994142,3.2341587317318194,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB60(460),Thornova Solar,Mono-c-Si,1,460.0,434.4,2.14,,,60.0,13.63,41.78,13.19,34.89,0.00564282,-0.09697138,43.4,1.4891788650762958,13.630001848278294,8.913451315245978e-12,0.13473516054297466,993485.5369011568,13.087565660983369,-0.3222,N,2025.7.3,6/23/2025,2.0,bootstrapping +Thornova Solar TS-BBT54(460),Thornova Solar,Mono-c-Si,1,460.0,437.3,1.94,,,54.0,14.05,39.56,13.55,34.04,0.0060415,-0.08889132000000001,43.4,1.338830357862443,14.05000234558499,2.065678231167611e-12,0.08759375829534094,524685.2888297498,3.286825077170147,-0.2989,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG60(460),Thornova Solar,Mono-c-Si,1,460.0,435.1,2.14,,,60.0,13.63,41.78,13.19,34.89,0.005520150000000001,-0.09738918,43.3,1.4504397055422098,13.630004357209344,4.21323611476259e-12,0.17663089753042294,552530.0385604415,5.897952120650554,-0.3152,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(460),Thornova Solar,Mono-c-Si,1,460.0,437.1,1.94,,,54.0,14.2,39.92,13.57,33.93,0.006801799999999999,-0.08710544,43.4,1.3972860379584493,14.202211196685766,5.533786026615438e-12,0.11310644414401963,726.3539810207868,15.269215498247473,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB60(460),Thornova Solar,Mono-c-Si,0,460.0,434.1,2.14,,,60.0,13.63,41.78,13.19,34.89,0.00575186,-0.09885148,43.3,1.46035365910913,13.630004315429384,5.1232085906789225e-12,0.17494641971327193,552559.467045436,5.990074998572586,-0.3284,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT54(460),Thornova Solar,Mono-c-Si,0,460.0,438.0,1.94,,,54.0,14.05,39.56,13.54,34.01,0.00636465,-0.09142316,43.1,1.3801459169928527,14.050001010066646,5.002835775418168e-12,0.07189022208222595,999996.8158989078,8.002916604797145,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB60(465),Thornova Solar,Mono-c-Si,1,465.0,439.2,2.14,,,60.0,13.73,41.92,13.28,35.02,0.00568422,-0.09729632,43.4,1.4503217078642217,13.730004402645484,3.844590519667355e-12,0.1757281272309045,548024.1844943918,5.480646053554878,-0.3222,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG60(465),Thornova Solar,Mono-c-Si,1,465.0,439.9,2.14,,,60.0,13.73,41.92,13.28,35.02,0.00556065,-0.09771552,43.3,1.4529214041355412,13.730004391525974,4.048654432491993e-12,0.17528815756223834,548036.3381321575,5.487189710751127,-0.3152,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SB60(465),Thornova Solar,Mono-c-Si,0,465.0,438.9,2.14,,,60.0,13.73,41.92,13.28,35.02,0.00579406,-0.09918272,43.3,1.5080830170305368,13.730001821074513,1.1631572249577778e-11,0.131409739649351,990658.4773914869,13.280395369984147,-0.3284,N,2025.7.3,6/23/2025,2.0,bootstrapping +Thornova Solar TS-BG60(470),Thornova Solar,Mono-c-Si,1,470.0,444.8,2.14,,,60.0,13.83,42.06,13.37,35.15,0.00560115,-0.09804186000000001,43.3,1.45558972668191,13.830004422917733,3.905364592146596e-12,0.1739333257180052,543873.2989984588,5.111290605059148,-0.3152,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT60(470),Thornova Solar,Mono-c-Si,1,470.0,446.4,2.14,,,60.0,13.61,43.16,12.99,36.19,0.00643753,-0.09758475999999999,43.2,1.4979955482627647,13.61317399580136,4.161598621299451e-12,0.17131756022633007,734.604629750372,9.019922967621918,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT60(475),Thornova Solar,Mono-c-Si,1,475.0,451.2,2.14,,,60.0,13.72,43.28,13.07,36.35,0.006489560000000001,-0.09785608,43.2,1.504558725742468,13.724883758700642,4.3819904112357096e-12,0.16516830891855372,464.00924906997074,9.422454652657606,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT60(480),Thornova Solar,Mono-c-Si,1,480.0,456.3,2.14,,,60.0,13.58,43.14,12.98,36.97,0.00607026,-0.10021422,43.2,1.5042796313730342,13.58206062620887,4.744185408641562e-12,0.10338834601386523,681.3530147348254,7.30029604271657,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT60(480),Thornova Solar,Mono-c-Si,1,480.0,456.1,2.14,,,60.0,13.84,43.35,13.15,36.51,0.0065463200000000004,-0.09801435,43.2,1.5106761045811676,13.846995313028893,4.7259819348995416e-12,0.1551189041308926,306.8977227187186,10.041357313916665,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT60(480),Thornova Solar,Mono-c-Si,0,480.0,456.5,2.14,,,60.0,13.58,43.14,12.98,36.97,0.00615174,-0.09969654,43.1,1.5031973492556925,13.58207855308432,4.64708997120837e-12,0.1035811257580396,676.7363502310001,7.669351770929088,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(485)-G12R,Thornova Solar,Mono-c-Si,1,485.0,460.6,2.2,,,54.0,15.77,39.2,14.85,32.68,0.00663917,-0.086436,43.2,1.3569504572138058,15.78953824636876,4.398540624713745e-12,0.1494942314633454,120.66200765643784,11.105531611228866,-0.2979,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT60(485),Thornova Solar,Mono-c-Si,1,485.0,461.2,2.14,,,60.0,13.65,43.27,13.08,37.09,0.00610155,-0.10051621000000001,43.2,1.5072477579443855,13.65072945895876,4.642297600842385e-12,0.10273581117475153,1922.4438733316495,7.050913751521855,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(485)-G12R,Thornova Solar,Mono-c-Si,1,485.0,460.8,2.2,,,54.0,15.77,39.2,14.85,32.68,0.0071280399999999996,-0.0860832,43.2,1.3570572147467717,15.789532630270989,4.408562989294793e-12,0.14947787079698885,120.68349179074595,11.539967450912261,-0.2955,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT60(485),Thornova Solar,Mono-c-Si,1,485.0,460.9,2.14,,,60.0,13.97,43.41,13.23,36.66,0.006607810000000001,-0.09815001,43.2,1.5169109513806471,13.979392925585818,5.138421327941555e-12,0.1451295714409635,215.84969430899477,10.734521322483102,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT60(485),Thornova Solar,Mono-c-Si,0,485.0,461.4,2.14,,,60.0,13.65,43.27,13.08,37.09,0.00618345,-0.09999697,43.1,1.5061664529268337,13.650744919345117,4.547459389702313e-12,0.10292686385930691,1886.0454596277875,7.419353987288498,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(490)-G12R,Thornova Solar,Mono-c-Si,1,490.0,465.4,2.2,,,54.0,15.8,39.5,14.91,32.88,0.0066518,-0.08709750000000001,43.2,1.3650793164108175,15.817429630913225,4.212526914993666e-12,0.15422839817624753,139.80839331829037,10.681218084378033,-0.2979,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT60(490),Thornova Solar,Mono-c-Si,1,490.0,466.0,2.14,,,60.0,13.74,43.42,13.18,37.2,0.0061417799999999995,-0.10086466000000001,43.2,1.5114144362596456,13.74016022012442,4.585656125851492e-12,0.10413719057127534,8930.494852192121,6.879508868409663,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT54(490)-G12R,Thornova Solar,Mono-c-Si,1,490.0,465.6,2.2,,,54.0,15.8,39.5,14.91,32.88,0.0071416,-0.086742,43.2,1.3651912204920358,15.817424013041899,4.222545092046883e-12,0.1542113462107629,139.83800229764213,11.114706688711406,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT60(490),Thornova Solar,Mono-c-Si,1,490.0,465.8,2.14,,,60.0,14.1,43.45,13.31,36.81,0.0066692999999999995,-0.09824045,43.2,1.5227839549678794,14.111331845481724,5.61846263563578e-12,0.13374960481744344,166.42209213632052,11.483845901896657,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT60(490),Thornova Solar,Mono-c-Si,0,490.0,466.2,2.14,,,60.0,13.74,43.42,13.18,37.2,0.00622422,-0.10034362000000001,43.1,1.5103322093760552,13.740174964473564,4.492086715980874e-12,0.10432684515842892,8192.811271284614,7.24751264144706,-0.2933,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT54(495)-G12R,Thornova Solar,Mono-c-Si,1,495.0,470.3,2.2,,,54.0,15.83,39.8,14.96,33.1,0.00666443,-0.08775899999999999,43.2,1.3739972250149939,15.845888636985965,4.100893066715923e-12,0.15739355812995467,156.81269769015992,10.411023482603877,-0.2979,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT60(495),Thornova Solar,Mono-c-Si,1,495.0,470.9,2.14,,,60.0,13.83,43.57,13.28,37.31,0.00618201,-0.10121311000000001,43.2,1.5165833623635971,13.83000142613335,4.612673932046062e-12,0.1031182369397499,999999.4010565344,6.872309452432789,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(495)-G12R,Thornova Solar,Mono-c-Si,1,495.0,470.5,2.2,,,54.0,15.83,39.8,14.97,33.1,0.007155159999999999,-0.08740079999999999,43.2,1.37371014983318,15.84507167626203,4.079339278717464e-12,0.15738712948343767,165.3059768192616,10.769973200195539,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT60(495),Thornova Solar,Mono-c-Si,1,495.0,470.7,2.14,,,60.0,14.23,43.49,13.39,36.96,0.00673079,-0.09833089,43.2,1.5286684706087736,14.24285230699996,6.14052846554227e-12,0.12250255486558988,135.63412067716877,12.2337901644333,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT60(495),Thornova Solar,Mono-c-Si,0,495.0,471.1,2.14,,,60.0,13.83,43.57,13.28,37.31,0.006264990000000001,-0.10069027000000001,43.1,1.5154634775926632,13.830001429894116,4.515779233434026e-12,0.10339017513901562,999999.4176545879,7.234727314578265,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT54(500)-G12R,Thornova Solar,Mono-c-Si,1,500.0,475.2,2.2,,,54.0,15.86,40.1,15.03,33.3,0.006677059999999999,-0.0884205,43.2,1.3817266311039669,15.872707841865486,3.90162811421892e-12,0.16206835491213262,202.26912959075327,9.925782458729055,-0.2979,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT60(500),Thornova Solar,Mono-c-Si,1,500.0,475.8,2.14,,,60.0,13.92,43.72,13.37,37.42,0.0062222399999999995,-0.10156156,43.2,1.521668107895803,13.920001440049209,4.630746369587512e-12,0.1034512013386533,999999.2176237765,6.849626929292911,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(500)-G12R,Thornova Solar,Mono-c-Si,1,500.0,475.4,2.2,,,54.0,15.86,40.1,15.03,33.3,0.007168719999999999,-0.0880596,43.2,1.3818474441453596,15.87270220707319,3.911555352629616e-12,0.16205014183976288,202.3361165034808,10.357490623866209,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT60(500),Thornova Solar,Mono-c-Si,1,500.0,475.5,2.14,,,60.0,14.36,43.53,13.48,37.11,0.00679228,-0.09842133,43.2,1.5340329323818156,14.37350252467061,6.648204428659838e-12,0.111474683564871,118.55386281385216,12.897558829914153,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT60(500),Thornova Solar,Mono-c-Si,0,500.0,476.0,2.14,,,60.0,13.92,43.72,13.37,37.42,0.00630576,-0.10103691999999999,43.1,1.5205447314423564,13.920001443828298,4.533485955699064e-12,0.10372269618404066,999999.2226797197,7.211985553874085,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT54(505)-G12R,Thornova Solar,Mono-c-Si,1,505.0,480.0,2.2,,,54.0,15.89,40.4,15.08,33.5,0.006689690000000001,-0.089082,43.2,1.3902609957876388,15.901051088115205,3.771442045945201e-12,0.16669065040655595,239.67906259771877,9.592845206080247,-0.2979,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT60(505),Thornova Solar,Mono-c-Si,1,505.0,480.6,2.14,,,60.0,14.01,43.87,13.47,37.52,0.00626247,-0.10191001,43.2,1.527043653026294,14.010001433158905,4.674282578014938e-12,0.10229468776730606,999997.885715243,6.875274767334358,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT54(505)-G12R,Thornova Solar,Mono-c-Si,1,505.0,480.2,2.2,,,54.0,15.89,40.4,15.08,33.5,0.00718228,-0.08871839999999999,43.2,1.3903853634905567,15.901045405687594,3.781272862257383e-12,0.16667198999127716,239.77552291402105,10.023645732107513,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-SBT60(505),Thornova Solar,Mono-c-Si,0,505.0,480.8,2.14,,,60.0,14.01,43.87,13.47,37.52,0.00634653,-0.10138356999999999,43.1,1.5259160372005058,14.010001436977529,4.5760942601287605e-12,0.10256725970793645,999997.8858262311,7.23770497049401,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT60(510),Thornova Solar,Mono-c-Si,1,510.0,485.5,2.14,,,60.0,14.09,44.02,13.57,37.61,0.006298229999999999,-0.10225846000000001,43.2,1.532690717291245,14.09000140482893,4.738643816408627e-12,0.09970130887505145,999978.3803716779,6.94557583631175,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-SBT60(510),Thornova Solar,Mono-c-Si,0,510.0,485.7,2.14,,,60.0,14.09,44.02,13.57,37.61,0.00638277,-0.10173022000000001,43.1,1.531558251852223,14.090001408712121,4.639071713362466e-12,0.09997666077572967,999975.8878532449,7.308213069436534,-0.2933,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BB72(530),Thornova Solar,Mono-c-Si,0,530.0,493.6,2.58,,,72.0,13.71,49.26,13.08,40.54,0.004304939999999999,-0.1290612,45.97,1.7706087021321995,13.710799494437223,1.1329592141440107e-11,0.24776127964324068,4248.688552361728,2.1774444522192256,-0.3426,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG72(530),Thornova Solar,Mono-c-Si,1,530.0,496.7,2.58,,,72.0,13.71,49.26,13.08,40.54,0.008034059999999999,-0.12630264,45.98,1.7602150692750367,13.711094124120244,9.610536492173576e-12,0.2495164865770928,3126.583110222422,2.6544672224934835,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB72(535),Thornova Solar,Mono-c-Si,0,535.0,498.4,2.58,,,72.0,13.79,49.34,13.16,40.66,0.004330059999999999,-0.12927080000000002,45.97,1.7744133420478339,13.79059334071766,1.156517131961513e-11,0.2420098240056031,5624.621687738559,2.299437332639005,-0.3426,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG72(535),Thornova Solar,Mono-c-Si,1,535.0,501.5,2.58,,,72.0,13.79,49.34,13.16,40.66,0.00808094,-0.12650776000000002,45.98,1.764002513425715,13.790881659938663,9.812020558553735e-12,0.24375887949532488,3812.6229169401017,2.7794339777658807,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB72(540),Thornova Solar,Mono-c-Si,0,540.0,503.2,2.58,,,72.0,13.85,49.42,13.27,40.71,0.0043489,-0.12948040000000002,45.97,1.779198059265098,13.850006400450654,1.1974039362709172e-11,0.24194458597887739,523551.8015363397,2.5503542291964147,-0.3426,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG72(540),Thornova Solar,Mono-c-Si,1,540.0,506.3,2.58,,,72.0,13.85,49.42,13.27,40.71,0.008116100000000001,-0.12671288000000003,45.98,1.7680502818352666,13.850006448269982,1.0050337909828868e-11,0.2437908445646252,523634.0094201404,2.9419682131161218,-0.3135,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BB72(545),Thornova Solar,Mono-c-Si,0,545.0,507.9,2.58,,,72.0,13.94,49.51,13.38,40.76,0.00437716,-0.1297162,45.97,1.7832729753570757,13.940003143799126,1.2209614296547493e-11,0.22551579153318135,999984.0876172846,2.6588247997495533,-0.3426,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BG72(545),Thornova Solar,Mono-c-Si,1,545.0,514.7,2.58,,,72.0,13.94,49.51,13.38,40.76,0.00598026,-0.12120047999999999,43.4,1.750684063779769,13.940003252930142,7.282005086648578e-12,0.23334553363288837,999983.4013050641,5.212007165800533,-0.3195,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BB72(550),Thornova Solar,Mono-c-Si,0,550.0,512.7,2.58,,,72.0,14.04,49.6,13.48,40.83,0.00440856,-0.129952,45.97,1.7866612943777738,14.040003292977103,1.2325256577356363e-11,0.22357059867692167,953236.1394965183,2.6778439722247067,-0.3426,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BG72(550),Thornova Solar,Mono-c-Si,1,550.0,519.6,2.58,,,72.0,14.04,49.6,13.48,40.83,0.00602316,-0.12142080000000001,43.4,1.754008548226088,14.040003248660236,7.351062195517117e-12,0.23137524420482286,999965.4293003253,5.2317517237840745,-0.3195,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BB72(555),Thornova Solar,Mono-c-Si,0,555.0,517.5,2.58,,,72.0,14.13,49.69,13.58,40.88,0.00443682,-0.13018780000000002,45.97,1.7902088035188544,14.130003493966575,1.24631823310568e-11,0.2208096234782708,892994.2409317327,2.7174017487902677,-0.3426,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BG72(555),Thornova Solar,Mono-c-Si,1,555.0,524.4,2.58,,,72.0,14.13,49.68,13.58,40.89,0.00606177,-0.12161664,43.4,1.7574551688946218,14.130003584110687,7.4720638217024e-12,0.22716645398553087,895590.7599083484,5.3174433235229515,-0.3195,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BG72(560),Thornova Solar,Mono-c-Si,1,560.0,529.2,2.58,,,72.0,14.25,49.76,13.68,40.95,0.006113250000000001,-0.12181247999999999,43.4,1.7432192150560677,14.250006782288292,5.71378804711427e-12,0.24756153650203552,520144.7149107298,2.9533318131725443,-0.3195,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BG72(565),Thornova Solar,Mono-c-Si,1,565.0,534.1,2.58,,,72.0,14.37,49.84,13.78,41.01,0.00616473,-0.12200832000000002,43.4,1.761311256950244,14.370003343753945,7.382121157360099e-12,0.23268594738392034,999995.5212580801,5.067931356599313,-0.3195,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT72(580),Thornova Solar,Mono-c-Si,1,580.0,551.5,2.56,,,72.0,13.61,51.9,13.04,44.48,0.006083669999999999,-0.12056370000000001,43.2,1.8078264712987235,13.610792810364853,4.625510461236873e-12,0.12421352264122547,2132.346282110057,7.045417448517099,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT72(580),Thornova Solar,Mono-c-Si,1,580.0,550.8,2.58,,,72.0,13.8,51.97,13.17,44.04,0.0066102,-0.11339854000000002,43.2,1.817664000300344,13.803125729230576,5.254150556728906e-12,0.1627122094547879,718.3695302270349,15.054323851813411,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT72(585),Thornova Solar,Mono-c-Si,1,585.0,556.4,2.56,,,72.0,13.68,52.09,13.12,44.61,0.00611496,-0.12100507,43.2,1.813024904970843,13.68024770307218,4.551429487035281e-12,0.12700424073804642,7014.1159299456995,6.8528499035919355,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT72(585),Thornova Solar,Mono-c-Si,1,585.0,555.6,2.58,,,72.0,13.85,52.16,13.23,44.22,0.00663415,-0.11381311999999999,43.2,1.823919226154969,13.852462747566115,5.2465144194408565e-12,0.16118455059536885,906.469699457032,15.001625790206443,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT72(590),Thornova Solar,Mono-c-Si,1,590.0,561.2,2.56,,,72.0,13.75,52.25,13.19,44.74,0.00614625,-0.12137674999999999,43.2,1.818284926480838,13.75012373359783,4.553654279193553e-12,0.1273787709031848,14155.073693393153,6.8110997296218185,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT72(590),Thornova Solar,Mono-c-Si,1,590.0,560.5,2.58,,,72.0,13.9,52.35,13.29,44.4,0.0066581,-0.11422770000000002,43.2,1.830175701562888,13.901812632426042,5.2390963884089335e-12,0.1596703927183114,1224.4172853362254,14.94947471555853,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT72(595),Thornova Solar,Mono-c-Si,1,595.0,566.1,2.56,,,72.0,13.82,52.47,13.27,44.85,0.0061775400000000005,-0.12188780999999999,43.2,1.8250342425221109,13.82000180799379,4.5131202992139254e-12,0.13082381197122978,999999.4478866692,6.686691246958258,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT66(595)-G12R,Thornova Solar,Mono-c-Si,1,595.0,565.0,2.68,,,66.0,15.76,48.1,14.89,40.0,0.00672952,-0.09874930000000001,43.2,1.6580400494232395,15.776250697187844,3.907245811331273e-12,0.19166847217667013,185.88095577411974,18.20875110383482,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT72(595),Thornova Solar,Mono-c-Si,1,595.0,565.3,2.58,,,72.0,13.95,52.54,13.35,44.58,0.006682049999999999,-0.11464228,43.2,1.8364333892315319,13.951175184255488,5.231890466016538e-12,0.15816956144034586,1877.5483059377145,14.897859710684434,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT72(600),Thornova Solar,Mono-c-Si,1,600.0,571.0,2.56,,,72.0,13.89,52.66,13.35,44.97,0.006208829999999999,-0.12232918,43.2,1.831656348407784,13.89000181228115,4.536937094411322e-12,0.13047306816304735,999998.5993616702,6.688546650225211,-0.2942,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT66(600)-G12R,Thornova Solar,Mono-c-Si,1,600.0,569.8,2.68,,,66.0,15.8,48.4,14.91,40.3,0.0067466,-0.0993652,43.2,1.6701888728967653,15.817480907312417,4.03600603910699e-12,0.18850403421579606,170.37809827528113,18.50827128844004,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT72(600),Thornova Solar,Mono-c-Si,1,600.0,570.2,2.58,,,72.0,14.0,52.73,13.41,44.76,0.006706,-0.11505686,43.2,1.8426922906788894,14.000550226659524,5.2248937577377464e-12,0.156681879480134,3986.623661839641,14.846775308475907,-0.3009,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT72(605),Thornova Solar,Mono-c-Si,1,605.0,575.8,2.56,,,72.0,13.96,52.85,13.43,45.08,0.00624012,-0.12277054999999999,43.2,1.8381245243694462,13.960088948962955,4.549058008891652e-12,0.14121057338410833,22162.145948798137,6.668485288206983,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT66(605)-G12R,Thornova Solar,Mono-c-Si,1,605.0,574.7,2.68,,,66.0,15.83,48.7,14.94,40.5,0.00675941,-0.09998110000000002,43.2,1.6795243543185212,15.847631598057049,3.974315010430969e-12,0.19310241130551856,173.37119214261395,18.337701775009208,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT72(605),Thornova Solar,Mono-c-Si,1,605.0,575.1,2.58,,,72.0,14.05,52.92,13.47,44.94,0.00672995,-0.11547144000000001,43.2,1.8490936212022002,14.05000217599541,5.228962326047443e-12,0.1548742335862299,999999.748243461,14.816355692784356,-0.3009,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BBT72(610),Thornova Solar,Mono-c-Si,1,610.0,580.7,2.56,,,72.0,14.03,53.04,13.5,45.2,0.00627141,-0.12321192,43.2,1.8441822819930962,14.030094237510772,4.532780439412368e-12,0.14449839307959242,21512.800147484806,6.593041169750298,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT66(610)-G12R,Thornova Solar,Mono-c-Si,1,610.0,579.6,2.68,,,66.0,15.86,49.0,14.96,40.8,0.00677222,-0.100597,43.2,1.691225649780429,15.878072322726267,4.072333049467444e-12,0.19007705752813414,166.80878166129799,18.561326572658878,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT72(610),Thornova Solar,Mono-c-Si,1,610.0,579.9,2.58,,,72.0,14.1,53.11,13.53,45.12,0.006753899999999999,-0.11588602,43.2,1.8566821966105014,14.100002118741463,5.324956962757891e-12,0.15026446375767513,999999.4788587465,14.954862404101613,-0.3009,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT78(610),Thornova Solar,Mono-c-Si,1,610.0,579.4,2.77,,,78.0,13.64,55.59,12.97,47.04,0.006451720000000001,-0.12568899,43.2,1.9407867449591059,13.645896739836727,4.912297428829425e-12,0.18253715912681706,422.2344764698349,10.523052419297606,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BBT72(615),Thornova Solar,Mono-c-Si,1,615.0,585.6,2.56,,,72.0,14.1,53.23,13.58,45.32,0.006302699999999999,-0.12365329,43.2,1.8506819350751837,14.100075720632505,4.548025644466236e-12,0.14767351701017262,27498.408974059537,6.578658880508376,-0.2942,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT66(615)-G12R,Thornova Solar,Mono-c-Si,1,615.0,584.4,2.68,,,66.0,15.89,49.3,14.98,40.98,0.006785030000000001,-0.10121290000000001,43.2,1.7006761021981525,15.909156570341151,4.015718160330517e-12,0.19616124624455772,162.71191297558158,18.407869281432394,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT78(615),Thornova Solar,Mono-c-Si,1,615.0,584.2,2.77,,,78.0,13.69,55.79,13.02,47.24,0.00647537,-0.12614119,43.2,1.9481921714860209,13.695726122443466,4.961864386627458e-12,0.17986490125991686,430.0205819838519,10.580478680798741,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT66(620)-G12R,Thornova Solar,Mono-c-Si,1,620.0,589.3,2.68,,,66.0,15.92,49.6,15.03,41.22,0.00679784,-0.10182880000000001,43.2,1.7097798544529874,15.93745528049163,3.945995863530105e-12,0.19771717417990517,180.32694566151588,18.210173897445536,-0.2994,N,2025.7.3,6/23/2025,2.0,first_pass +Thornova Solar TS-BGT78(620),Thornova Solar,Mono-c-Si,1,620.0,589.1,2.77,,,78.0,13.74,55.99,13.07,47.44,0.00649902,-0.12659339,43.2,1.9555971364366223,13.745558714367338,5.0115893033964e-12,0.17721343147622035,438.0351993225595,10.637433503575975,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT78(625),Thornova Solar,Mono-c-Si,1,625.0,593.9,2.77,,,78.0,13.79,56.18,13.13,47.61,0.00652267,-0.12702297999999998,43.2,1.9615719239325253,13.794883331769055,4.98692037153461e-12,0.1764980525633966,498.4113854499359,10.554764783234699,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT78(630),Thornova Solar,Mono-c-Si,1,630.0,598.8,2.77,,,78.0,13.84,56.37,13.18,47.8,0.0065463200000000004,-0.12745257,43.2,1.9685978283001566,13.844732031919417,5.034418482766182e-12,0.17398200492612617,508.85349000783754,10.60747395483607,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT78(635),Thornova Solar,Mono-c-Si,1,635.0,603.6,2.77,,,78.0,13.89,56.56,13.23,47.99,0.00656997,-0.12788216,43.2,1.9756233820646332,13.89458363521651,5.082065245421677e-12,0.17148525391300115,519.6596305702643,10.659782384152802,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT78(640),Thornova Solar,Mono-c-Si,1,640.0,608.5,2.77,,,78.0,13.94,56.75,13.28,48.18,0.00659362,-0.12831175,43.2,1.9826485906448814,13.944438108205711,5.129859786243194e-12,0.1690075776666732,530.849074147609,10.711695292806946,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT78(645),Thornova Solar,Mono-c-Si,1,645.0,613.4,2.77,,,78.0,13.99,56.94,13.34,48.37,0.00661727,-0.12874134,43.2,1.9890049327470345,13.993779959034955,5.132715460371688e-12,0.16664075200580403,616.7538070481579,10.679733651124389,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT78(650),Thornova Solar,Mono-c-Si,1,650.0,618.2,2.77,,,78.0,14.04,57.13,13.39,48.56,0.00664092,-0.12917093000000002,43.2,1.9960294092216873,14.043647915315384,5.180547414424217e-12,0.1642021289168316,631.9768166771421,10.73113518859462,-0.2972,N,2025.7.3,6/23/2025,4.0,first_pass +Thornova Solar TS-BGT66(690)-G12,Thornova Solar,Mono-c-Si,1,690.0,655.7,3.08,,,66.0,18.25,47.9,17.23,40.1,0.00830375,-0.1083498,43.1,1.6672401711432392,18.267781477262755,5.97973328580343e-12,0.1458628816141765,149.70621133699012,9.673248622312311,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(695)-G12,Thornova Solar,Mono-c-Si,1,695.0,660.6,3.08,,,66.0,18.28,48.3,17.25,40.3,0.0083174,-0.10925460000000001,43.1,1.6789011398648839,18.29924571837101,5.760684060781123e-12,0.15571377353308513,147.90031366943873,9.322351379442448,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(700)-G12,Thornova Solar,Mono-c-Si,1,700.0,665.4,3.08,,,66.0,18.32,48.6,17.29,40.5,0.0083356,-0.10993320000000002,43.1,1.6882500728482785,18.339415618661462,5.669616538387385e-12,0.15965424256945288,150.64499251076631,9.157996162258549,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(705)-G12,Thornova Solar,Mono-c-Si,1,705.0,670.3,3.08,,,66.0,18.36,48.8,17.33,40.7,0.0083538,-0.1103856,43.1,1.6957491018450035,18.37908859307598,5.735877712541046e-12,0.157776749741249,151.7545644933562,9.242655308626382,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(710)-G12,Thornova Solar,Mono-c-Si,1,710.0,675.2,3.08,,,66.0,18.4,49.0,17.36,40.9,0.008372,-0.110838,43.1,1.7036858017692358,18.419519613027155,5.841521221007761e-12,0.15588933321037554,146.9477766205501,9.390148667434826,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(715)-G12,Thornova Solar,Mono-c-Si,1,715.0,680.0,3.08,,,66.0,18.44,49.2,17.39,41.1,0.0083902,-0.11129040000000001,43.1,1.7116252202268332,18.459931375251344,5.948449935893037e-12,0.15400790211647547,142.4841829939488,9.536764623949121,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(720)-G12,Thornova Solar,Mono-c-Si,1,720.0,684.9,3.08,,,66.0,18.48,49.4,17.42,41.3,0.0084084,-0.1117428,43.1,1.7195672759750091,18.500324166865013,6.056665057579722e-12,0.15213241139661055,138.3282761227397,9.682577178296201,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(725)-G12,Thornova Solar,Mono-c-Si,1,725.0,689.8,3.08,,,66.0,18.52,49.6,17.45,41.5,0.0084266,-0.11219520000000002,43.1,1.727511959302923,18.5406982668609,6.166173545904534e-12,0.1502628306145541,134.44930655266353,9.827593691241294,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +Thornova Solar TS-BGT66(730)-G12,Thornova Solar,Mono-c-Si,1,730.0,694.6,3.08,,,66.0,18.56,49.8,17.48,41.7,0.008444799999999999,-0.1126476,43.1,1.735459258143483,18.581053948678818,6.276982145562857e-12,0.14839912802170419,130.82048699243222,9.971824041320648,-0.2977,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM754-420G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,420.0,396.3,1.95,,,18.0,13.83,38.5,13.17,31.9,0.0066384,-0.09009,45.49,1.3272218669193416,13.835598026750175,3.4700150680785373e-12,0.18382624773295886,454.1452097017701,3.6019288765091373,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM754-425G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,425.0,401.2,1.95,,,18.0,13.91,38.7,13.24,32.1,0.0066768,-0.09055800000000001,45.49,1.335054464310224,13.916152298325406,3.559650871771525e-12,0.18077044392179006,408.71179368591106,3.77380135449675,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-425G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,425.0,400.0,2.0,,,16.0,15.17,35.61,14.34,29.64,0.0072816,-0.08332740000000001,46.36,1.2327693613281978,15.184627586048814,4.260349790073025e-12,0.1445111248629018,149.86982541052072,4.60799904039787,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM754-430G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,430.0,406.0,1.95,,,18.0,13.99,38.9,13.32,32.3,0.0067152,-0.09102600000000001,45.49,1.3424456115019405,13.995854909367727,3.619195063151792e-12,0.17775523294768827,424.736842556227,3.8661020374975217,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-430G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,430.0,404.8,2.0,,,16.0,15.27,35.77,14.44,29.78,0.0073296,-0.0837018,46.36,1.238232300281762,15.2842521428829,4.282636651344649e-12,0.14367956646125035,153.94084956585374,4.59466324152311,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM754-435G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,435.0,410.8,1.95,,,18.0,14.07,39.1,13.39,32.5,0.006753600000000001,-0.091494,45.49,1.3502786288325583,14.076380627088893,3.710991396038052e-12,0.1747658028085377,385.3782424970615,4.034946892760906,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-435G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,435.0,409.6,2.0,,,16.0,15.37,35.93,14.54,29.92,0.007377600000000001,-0.0840762,46.36,1.2436962030935441,15.38387986378444,4.3049941166713565e-12,0.1428591828294594,158.19648361901181,4.5816280248915,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM754-440G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,440.0,415.7,1.95,,,18.0,14.15,39.3,13.46,32.7,0.006792000000000001,-0.091962,45.49,1.3581125480392973,14.156885223951985,3.804216663013949e-12,0.17180740319495016,353.0857934711683,4.202237067436969,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-440G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,440.0,414.4,2.0,,,16.0,15.47,36.09,14.64,30.06,0.0074256,-0.08445060000000001,46.36,1.2491610312175545,15.483510698719053,4.327418999623245e-12,0.14204975345574414,162.64959607407562,4.568881978021991,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM754-445G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,445.0,420.5,1.95,,,18.0,14.24,39.5,13.53,32.9,0.0068352000000000005,-0.09243000000000001,45.49,1.3663716015882275,14.248122199270036,3.933583832386462e-12,0.16874533030009575,295.8476429276322,4.441650669148134,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-445G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,445.0,419.3,2.0,,,16.0,15.57,36.25,14.74,30.2,0.0074736,-0.084825,46.36,1.254626801051358,15.58314460426388,4.3499135619458e-12,0.14125105544939648,167.31419924611728,4.556424529182927,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM754-450G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,450.0,425.4,1.95,,,18.0,14.33,39.7,13.6,33.1,0.006878400000000001,-0.09289800000000001,45.49,1.3746342582739939,14.339311768365619,4.066167092773083e-12,0.1657137115814674,255.01896082116298,4.6792873670513195,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-450G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,450.0,424.1,2.0,,,16.0,15.68,36.42,14.83,30.33,0.0075264,-0.08522280000000002,46.36,1.26081937843216,15.694407118305731,4.407009072499687e-12,0.1417894232518097,154.31664491892514,4.612496647734883,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM848-455G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,455.0,428.9,2.0,,,16.0,15.78,36.58,14.93,30.47,0.0075744,-0.08559720000000001,46.36,1.2662851346546917,15.794037142772186,4.429495424518125e-12,0.14100262067621522,158.50956232678558,4.599960963303472,-0.292,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-560G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,560.0,528.5,2.58,,,24.0,13.93,50.5,13.2,42.44,0.0066864,-0.11817000000000001,45.49,1.7563253485765487,13.939671975400369,4.4775134704815796e-12,0.18789806837332568,270.6189778226599,5.77257294007579,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-565G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,565.0,533.4,2.58,,,24.0,14.02,50.7,13.26,42.61,0.0067296,-0.11863800000000001,45.49,1.7648370927448545,14.03139803880337,4.611864466930563e-12,0.1871316729223324,230.17872667287676,5.983400012289776,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-570G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,570.0,538.2,2.58,,,24.0,14.1,50.9,13.33,42.77,0.006768,-0.119106,45.49,1.7719821578188668,14.111869993860306,4.6497481058202784e-12,0.18746292426926792,222.68143133481271,6.007074952285198,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-575G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,575.0,543.0,2.58,,,24.0,14.19,51.1,13.39,42.94,0.0068112,-0.11957400000000001,45.49,1.7804958036593053,14.203596453419113,4.787504860790861e-12,0.18670514341288158,194.85566614850433,6.215565847726623,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-580G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,580.0,547.9,2.58,,,24.0,14.28,51.3,13.45,43.11,0.006854400000000001,-0.12004200000000001,45.49,1.7890129022313048,14.295317394618754,4.928352692368439e-12,0.18595285605796685,173.3589070206046,6.4228764515162675,-0.293,N,2025.7.3,6/23/2025,4.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-585G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,585.0,552.7,2.58,,,24.0,14.36,51.5,13.52,43.27,0.0068928,-0.12051,45.49,1.7961538989528392,14.375803793483866,4.9669219332240796e-12,0.18628687037383723,169.26818640262297,6.4440117374430885,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-590G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,590.0,557.6,2.58,,,24.0,14.45,51.7,13.58,43.45,0.0069359999999999995,-0.12097800000000002,45.49,1.8048701134361986,14.467457261112408,5.1271561926943755e-12,0.18470499074478144,152.8869335094846,6.676488549075601,-0.293,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM772-595G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,595.0,562.4,2.58,,,24.0,14.53,51.9,13.64,43.61,0.0069743999999999995,-0.12144600000000001,45.49,1.8126202433794367,14.548609391348272,5.211794524827866e-12,0.18498571628681224,144.43473243679665,6.776902114371132,-0.293,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM866-595G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,595.0,560.5,2.7,,,22.0,15.7,48.29,14.54,40.92,0.007536,-0.1129986,46.36,1.7021726024343393,15.727810493558783,7.204082604877654e-12,0.131686300431731,74.3415399541992,9.029439982695838,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM866-600G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,600.0,565.3,2.7,,,22.0,15.78,48.44,14.62,41.05,0.0075744,-0.11334960000000001,46.36,1.7071866000352545,15.807594395386268,7.211358701830472e-12,0.13124535567143877,75.05334632874681,8.99112956966738,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM866-605G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,605.0,570.1,2.7,,,22.0,15.86,48.59,14.69,41.18,0.007612799999999999,-0.11370060000000001,46.36,1.712761724235864,15.887905856599899,7.280212974264025e-12,0.1307327946456053,74.30060843795765,9.032267889817428,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM866-610G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,610.0,574.9,2.7,,,22.0,15.94,48.74,14.77,41.31,0.0076511999999999995,-0.11405160000000002,46.36,1.7177772662385993,15.967690686751364,7.287538004533992e-12,0.1303010467385982,75.00712079964357,8.994401054367005,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM866-615G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,615.0,579.8,2.7,,,22.0,16.02,48.89,14.84,41.43,0.0076896,-0.11440260000000001,46.36,1.7231503848932275,16.048159859734913,7.33227150464703e-12,0.1305659643684561,74.27830859712772,9.005578292326542,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM866-620G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,620.0,584.6,2.7,,,22.0,16.11,49.04,14.92,41.56,0.0077328,-0.11475360000000001,46.36,1.728682907569624,16.138449742582626,7.401248697519366e-12,0.1299893478724657,73.60799098180318,9.040336194415751,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM866-625G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,625.0,589.5,2.7,,,22.0,16.19,49.19,14.99,41.69,0.007771200000000001,-0.1151046,46.36,1.734255897866093,16.218759822266954,7.470368687811851e-12,0.12949351952947455,72.89683722734226,9.080525041059131,-0.292,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM866-630G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,630.0,594.3,2.7,,,22.0,16.27,49.34,15.07,41.82,0.007809600000000001,-0.11545560000000002,46.36,1.7392730814995823,16.29854418421248,7.477561201049534e-12,0.12907647610898607,73.57275484557584,9.043200797091092,-0.292,N,2025.7.3,6/23/2025,2.0,first_pass +TIDESOLAR PHILIPPINES CORPORATION TDM966-685G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,685.0,645.5,3.11,,,22.0,18.23,47.77,17.28,39.65,0.0085681,-0.1122595,46.07,1.6520444281699314,18.244034512707646,4.988463921963764e-12,0.16838303226716195,218.71957708978758,3.936826622200614,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-690G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,690.0,650.3,3.11,,,22.0,18.28,47.97,17.33,39.82,0.008591600000000001,-0.1127295,46.07,1.6589286992357635,18.293844036837264,5.000154227672295e-12,0.16836490805346524,222.31308405390138,3.93285840803285,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-695G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,695.0,655.2,3.11,,,22.0,18.33,48.17,17.38,39.98,0.008615099999999999,-0.1131995,46.07,1.6656170715984298,18.34368199476361,4.994951425165586e-12,0.1690019088477213,226.41471867095046,3.8997021864951757,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-700G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,700.0,660.0,3.11,,,22.0,18.38,48.37,17.44,40.15,0.0086386,-0.11366949999999998,46.07,1.6720765318738664,18.39265794745317,4.9733594878055675e-12,0.1689893493876949,245.38135110809466,3.835844898339315,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-705G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,705.0,664.8,3.11,,,22.0,18.43,48.57,17.49,40.31,0.008662099999999999,-0.1141395,46.07,1.67876418040857,18.44249244518257,4.968418556444333e-12,0.16962070036047608,250.24000255492274,3.8033124279195896,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-710G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,710.0,669.7,3.11,,,22.0,18.48,48.77,17.54,40.48,0.008685600000000002,-0.1146095,46.07,1.685647040653481,18.49230452960689,4.9801396492972535e-12,0.16959965246377154,254.71933381758964,3.7996575193560624,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-715G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,715.0,674.5,3.11,,,22.0,18.53,48.97,17.59,40.65,0.008709100000000001,-0.1150795,46.07,1.692529616109778,18.54211730707694,4.99184376741023e-12,0.1695787995966138,259.32289604546526,3.7959931103404703,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-720G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,720.0,679.3,3.11,,,22.0,18.58,49.17,17.64,40.81,0.0087326,-0.1155495,46.07,1.699216617690031,18.5919503743526,4.987035304063757e-12,0.17020325809008105,264.6257304676312,3.76394063979418,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-725G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,725.0,684.2,3.11,,,22.0,18.63,49.37,17.69,40.98,0.0087561,-0.11601949999999998,46.07,1.7060987210808523,18.64176370012254,4.998742249332284e-12,0.17018094343760584,269.51307416105203,3.760337286707901,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +TIDESOLAR PHILIPPINES CORPORATION TDM966-730G,TIDESOLAR PHILIPPINES CORPORATION,Mono-c-Si,0,730.0,689.0,3.11,,,22.0,18.67,49.57,17.7,41.24,0.008774900000000002,-0.1164895,46.07,1.7160462731301256,18.683847735970375,5.261803325340231e-12,0.16444150567664736,221.70576632807305,4.190580686873136,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +Toenergy Technology Hangzhou CoLtd TN-MG120-435,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,435.0,411.2,2.16,,,60.0,13.67,40.72,12.63,34.46,0.004347060000000001,-0.09744296000000001,43.1,1.4516178363171013,13.695741836787862,8.602965094853887e-12,0.12852541039910576,68.25240856479907,9.6330123847305,-0.3146,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG120-440,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,440.0,416.0,2.16,,,60.0,13.72,40.88,12.73,34.57,0.004362960000000001,-0.09782584000000001,43.1,1.4537780886330216,13.743346120534714,8.104600735078697e-12,0.1313091324470043,77.16748040725567,9.04741380405239,-0.3146,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG120-445,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,445.0,420.8,2.16,,,60.0,13.77,41.04,12.84,34.68,0.00437886,-0.09820872,43.1,1.455450124101373,13.790250624664527,7.571119143082608e-12,0.13410687518378242,91.18986222094718,8.386487158453827,-0.3146,N,2025.7.3,6/23/2025,2.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG120-450,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,450.0,425.7,2.16,,,60.0,13.82,41.2,12.94,34.79,0.004394760000000001,-0.09859160000000002,43.1,1.457731739383438,13.837570094603926,7.1509987365920225e-12,0.13676068198767444,107.57099893555385,7.829938247498579,-0.3146,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG120-455,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,455.0,430.5,2.16,,,60.0,13.87,41.36,13.04,34.9,0.00441066,-0.09897448000000002,43.1,1.4600661264380177,13.884761250147998,6.7619892243442816e-12,0.1393558620339292,130.94187762965188,7.286217821846572,-0.3146,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG120-460,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,460.0,435.3,2.16,,,60.0,13.92,41.52,13.14,35.01,0.0044265599999999995,-0.09935736,43.1,1.4624514991078532,13.93182819020095,6.40131818708964e-12,0.1418943742603235,166.9883269717055,6.754892904017575,-0.3146,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-525,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,525.0,493.5,2.58,,,72.0,13.59,48.85,12.75,41.2,0.00455265,-0.12598415000000002,43.1,1.8021415942594226,13.603712679184314,2.244846940044172e-11,0.15598192628716429,154.58642285935397,9.86762278327995,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-530,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,530.0,498.3,2.58,,,72.0,13.65,49.04,12.83,41.33,0.00457275,-0.12647416,43.1,1.8068391921609135,13.662660330747103,2.1827863848635646e-11,0.15884621555941603,171.26336577758866,9.570576086847533,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-535,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,535.0,503.1,2.58,,,72.0,13.71,49.23,12.91,41.46,0.00459285,-0.12696417,43.1,1.8115549708674552,13.721554212910275,2.1233088895029675e-11,0.1616690094815571,191.83324273037422,9.278123010066004,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-540,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,540.0,507.9,2.58,,,72.0,13.77,49.42,12.99,41.59,0.00461295,-0.12745418000000003,43.1,1.8125260749470289,13.780499199831981,1.952626338043587e-11,0.16510126255235502,216.53501526983626,8.492392812191909,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-545,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,545.0,512.7,2.58,,,72.0,13.82,49.61,13.07,41.72,0.0046297000000000005,-0.12794419,43.1,1.8204042958808453,13.828616533454804,1.9927907852976766e-11,0.16739478391285134,268.4833702355201,8.626982716463472,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-550,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,550.0,517.6,2.58,,,72.0,13.89,49.8,13.15,41.85,0.00465315,-0.1284342,43.1,1.8258072517537212,13.897922472848682,1.9590632465312227e-11,0.16989739788989344,297.870997306774,8.427276157823572,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toenergy Technology Hangzhou CoLtd TN-MG144-555,Toenergy Technology Hangzhou CoLtd,Mono-c-Si,0,555.0,522.4,2.58,,,72.0,13.94,49.99,13.22,41.98,0.0046699,-0.12892421,43.1,1.8306257842367122,13.946637449696862,1.908161387649977e-11,0.17268291993981577,362.66947572532507,8.156409121387036,-0.3462,N,2025.7.3,6/23/2025,4.0,first_pass +Toledo Solar Inc TS1,Toledo Solar Inc,CdTe,0,115.0,106.8,0.72,,,108.0,1.81,87.1,1.7,69.0,0.00062083,-0.2628678,46.1,3.057293926224356,1.8133927094658115,7.553610775750226e-13,5.179938189243237,2763.480899334728,-16.15002440276855,-0.3258,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW240P-60,Tongwei Solar (Hefei),Multi-c-Si,0,240.0,215.4,1.6236,1.64,0.99,60.0,8.73,37.4,8.14,29.5,0.00460944,-0.11470579999999998,47.5,1.5035406257910335,8.746170106363746,1.351658730220523e-10,0.43175001413119585,233.09543491986048,10.264520947570054,-0.4312,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW245P-60,Tongwei Solar (Hefei),Multi-c-Si,0,245.0,220.1,1.6236,1.64,0.99,60.0,8.8,37.5,8.25,29.7,0.0046464,-0.11501249999999999,47.5,1.506929990207585,8.810021008036184,1.3564421869484754e-10,0.41166745063771903,361.50794872172025,10.206479884350884,-0.4312,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW250P-60,Tongwei Solar (Hefei),Multi-c-Si,0,250.0,224.7,1.6236,1.64,0.99,60.0,8.89,37.6,8.36,29.9,0.004693920000000001,-0.1153192,47.5,1.5120516192026967,8.896825860292042,1.3998194895391353e-10,0.3913486025745382,509.6924884144278,10.385968074701522,-0.4312,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW255P-60,Tongwei Solar (Hefei),Multi-c-Si,0,255.0,229.3,1.6236,1.64,0.99,60.0,8.97,37.7,8.42,30.1,0.00473616,-0.1156259,47.5,1.520826054084913,8.978839771533377,1.5225410090627028e-10,0.37214047170119957,377.62293712256866,11.06470330150589,-0.4312,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW260P-60,Tongwei Solar (Hefei),Multi-c-Si,0,260.0,233.9,1.6236,1.64,0.99,60.0,9.06,37.8,8.58,30.3,0.00478368,-0.1159326,47.5,1.5215098305537889,9.060151792279829,1.470783203696933e-10,0.3526552509610579,21048.979515577554,10.633767284235045,-0.4312,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW285P-72,Tongwei Solar (Hefei),Multi-c-Si,0,285.0,257.6,1.93644,1.956,0.99,72.0,8.67,44.8,8.1,35.2,0.0046818,-0.14116479999999998,46.8,1.7752642464173594,8.684689866708206,9.37613808707514e-11,0.5455720623239567,321.9981690547509,4.2242043825399564,-0.4176,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW290P-72,Tongwei Solar (Hefei),Multi-c-Si,0,290.0,262.2,1.93644,1.956,0.99,72.0,8.75,44.9,8.19,35.4,0.004725,-0.1414799,46.8,1.7810175181433163,8.762535047681492,9.723122797534506e-11,0.5240510965051203,365.81013834248574,4.4475410451034385,-0.4176,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW295P-72,Tongwei Solar (Hefei),Multi-c-Si,0,295.0,266.9,1.93644,1.956,0.99,72.0,8.82,45.0,8.26,35.7,0.0047628,-0.141795,46.8,1.7907234176937208,8.831905835510106,1.0624325478421976e-10,0.4894500148348604,362.59106038016165,5.1297247231474685,-0.4176,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW300P-72,Tongwei Solar (Hefei),Multi-c-Si,0,300.0,271.5,1.93644,1.956,0.99,72.0,8.89,45.1,8.36,35.9,0.0048006,-0.1421101,46.8,1.7943877558044055,8.897501355762051,1.0709499370786388e-10,0.46935506526271875,556.2417264813281,5.11692014710316,-0.4176,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW305P-72,Tongwei Solar (Hefei),Multi-c-Si,0,305.0,276.2,1.93644,1.956,0.99,72.0,8.96,45.2,8.45,36.1,0.0048384000000000005,-0.1424252,46.8,1.7991465118138075,8.964650335380686,1.094482467382614e-10,0.4497894402166793,866.6287160585119,5.225586251750723,-0.4176,N,2025.7.3,6/23/2025,4.0,first_pass +Tongwei Solar (Hefei) TW310P-72,Tongwei Solar (Hefei),Multi-c-Si,0,310.0,280.8,1.93644,1.956,0.99,72.0,9.04,45.3,8.52,36.4,0.0048816,-0.1427403,46.8,1.8097785512775177,9.045546347887008,1.2092886225400175e-10,0.4165020577698636,678.8573772827228,6.0039135914677075,-0.4176,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH120-355/M,TOPCO SOLAR INC,Mono-c-Si,0,355.0,331.3,1.8,,,60.0,11.14,40.4,10.57,33.6,0.005302640000000001,-0.10613079999999998,45.6,1.473281921991184,11.145387633112634,1.362471094732904e-11,0.20981556708502197,433.8352972095964,5.008578423496884,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH120-360/M,TOPCO SOLAR INC,Mono-c-Si,0,360.0,336.1,1.8,,,60.0,11.24,40.6,10.66,33.8,0.00535024,-0.1066562,45.6,1.4816311464731258,11.245759911271026,1.4009413512411609e-11,0.20532944544121465,400.6837743157577,5.172555015029031,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH120-365/M,TOPCO SOLAR INC,Mono-c-Si,0,365.0,340.9,1.8,,,60.0,11.33,40.8,10.74,34.0,0.005393080000000001,-0.10718159999999999,45.6,1.4900134809289745,11.336148031356695,1.4396076855716024e-11,0.20109307987581124,370.5876697902402,5.339875345190043,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH120-370/M,TOPCO SOLAR INC,Mono-c-Si,0,370.0,345.7,1.8,,,60.0,11.42,41.0,10.82,34.2,0.00543592,-0.107707,45.6,1.498395366915929,11.426518712918089,1.4789209792441286e-11,0.1969197696451449,344.97972458377575,5.505503606241051,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH120-375/M,TOPCO SOLAR INC,Mono-c-Si,0,375.0,350.5,1.8,,,60.0,11.51,41.2,10.91,34.4,0.00547876,-0.1082324,45.6,1.5061200464221607,11.51617749277998,1.5024945715303958e-11,0.19287948793638807,359.37604516910204,5.572316050950646,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SH108-390/M,TOPCO SOLAR INC,Mono-c-Si,0,390.0,359.3,1.94,,,54.0,13.56,36.7,12.79,30.5,0.00736308,-0.10918250000000002,45.37,1.4642276408412627,13.567627710675092,1.7471614057812704e-10,0.13739320176869668,244.24784909623122,11.993539884020604,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP108H-395MB,TOPCO SOLAR INC,Mono-c-Si,0,395.0,370.1,1.95,,,54.0,13.7,36.98,12.81,30.84,0.007411699999999999,-0.1005856,43.6,1.40122006338855,13.71787567418361,4.620631947858024e-11,0.1406954380129588,107.82964020136238,10.057139396209424,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP108H-400MB,TOPCO SOLAR INC,Mono-c-Si,0,400.0,374.9,1.95,,,54.0,13.79,37.04,12.9,31.01,0.00746039,-0.10074880000000001,43.6,1.406010320933918,13.806439128337905,4.876764567933979e-11,0.12931095808982845,108.47279063782672,10.479825330732238,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SH108-400/M,TOPCO SOLAR INC,Mono-c-Si,0,400.0,368.8,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007439099999999999,-0.1103725,45.37,1.480294688867116,13.705743463998656,1.7725662020202566e-10,0.13160420151602864,313.9181674412768,12.023035173395055,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP108H-405MB,TOPCO SOLAR INC,Mono-c-Si,0,405.0,379.7,1.95,,,54.0,13.87,37.23,12.98,31.21,0.00750367,-0.1012656,43.6,1.4139051525333008,13.885822213734135,4.969547650486629e-11,0.1256249050100731,110.12475724945544,10.595507247034014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SH108-405/M,TOPCO SOLAR INC,Mono-c-Si,0,405.0,373.5,1.94,,,54.0,13.77,37.3,13.03,31.1,0.0074771099999999995,-0.1109675,45.37,1.4883266455972926,13.774858282217933,1.7852278760185006e-10,0.12876427701722212,364.96114223748964,12.037274463906064,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP108H-410MB,TOPCO SOLAR INC,Mono-c-Si,0,410.0,384.5,1.95,,,54.0,13.95,37.32,13.04,31.45,0.007546949999999999,-0.10151040000000001,43.6,1.422020188570126,13.965049843575635,5.4423661536418076e-11,0.11054505869025638,102.46641916423748,11.366863738915423,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SH108-410/M,TOPCO SOLAR INC,Mono-c-Si,0,410.0,378.3,1.94,,,54.0,13.84,37.5,13.1,31.3,0.00751512,-0.1115625,45.37,1.4969436300951489,13.844611455842742,1.8139524561662978e-10,0.1258810638243036,377.79642901378406,12.134918135103467,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH144-430/M,TOPCO SOLAR INC,Mono-c-Si,0,430.0,401.5,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00491241,-0.1282545,45.7,1.7822749127684092,11.197622941581903,9.619271457369746e-12,0.3198069719849507,469.4565749366308,3.5168948825623616,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP120H-435MB,TOPCO SOLAR INC,Mono-c-Si,0,435.0,407.5,2.16,,,60.0,13.67,40.95,12.96,33.63,0.007395470000000001,-0.11138400000000001,43.6,1.5290244116054013,13.676148139014527,3.1761523952668715e-11,0.20361617907753368,452.7278143631316,6.721421091413095,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH144-435/M,TOPCO SOLAR INC,Mono-c-Si,0,435.0,406.3,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00494314,-0.12877270000000002,45.7,1.789972206459299,11.267298430122242,9.75734480831969e-12,0.3152333088639414,486.3411758535138,3.5834125788860685,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP120H-440MB,TOPCO SOLAR INC,Mono-c-Si,0,440.0,412.3,2.16,,,60.0,13.73,41.02,13.05,33.72,0.007427930000000001,-0.11157440000000003,43.6,1.5305495397668754,13.733250837708983,3.138945279212656e-11,0.20025165287596605,845.7682522336652,6.571426706940132,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH144-440/M,TOPCO SOLAR INC,Mono-c-Si,0,440.0,411.1,2.15,,,72.0,11.33,49.9,10.74,41.0,0.00497387,-0.1292909,45.7,1.7976698099741357,11.336980980561282,9.89637143342542e-12,0.31071959460617027,504.29205558800237,3.649427556698969,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP120H-445MB,TOPCO SOLAR INC,Mono-c-Si,0,445.0,417.2,2.16,,,60.0,13.79,41.1,13.16,33.82,0.00746039,-0.11179200000000002,43.6,1.5230357694994607,13.790005128939356,2.629508271735187e-11,0.19826140688761676,533072.2356760007,5.002385774862916,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH144-445/M,TOPCO SOLAR INC,Mono-c-Si,0,445.0,415.9,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0050046000000000005,-0.1298091,45.7,1.7951160234162518,11.400007192237391,8.632779720938824e-12,0.30815851925527477,488447.83020992915,2.419494898633385,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP120H-450MB,TOPCO SOLAR INC,Mono-c-Si,0,450.0,422.0,2.16,,,60.0,13.85,41.18,13.27,33.91,0.0074928500000000006,-0.11200960000000001,43.6,1.5301606964755194,13.850005010708049,2.842005641451503e-11,0.1947939459496308,538440.8843964805,5.629540063448199,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM6-NH144-450/M,TOPCO SOLAR INC,Mono-c-Si,0,450.0,420.7,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00503094,-0.1303273,45.7,1.8031391296985968,11.46001282194526,8.794033877456291e-12,0.30396324043616585,271677.3853751143,2.5303995683389298,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TP120H-455MB,TOPCO SOLAR INC,Mono-c-Si,0,455.0,426.8,2.16,,,60.0,13.93,41.33,13.36,34.06,0.007536130000000001,-0.1124176,43.6,1.5413926366914639,14.013466063613366,3.1741411496157716e-11,0.19047938999153652,999999.8801695533,6.4836709139633335,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-520/M,TOPCO SOLAR INC,Mono-c-Si,0,520.0,486.7,2.56,,,72.0,13.53,49.0,12.79,40.7,0.0059532,-0.118286,45.84,1.7462563589841997,13.54160083361372,8.694155949495618e-12,0.22143938147310896,258.26375429687414,8.565436880412744,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-525/M,TOPCO SOLAR INC,Mono-c-Si,0,525.0,491.5,2.56,,,72.0,13.59,49.2,12.85,40.9,0.005979599999999999,-0.11876880000000001,45.84,1.7145289226370168,13.602576390443899,4.619933196014363e-12,0.22525277540592395,243.40729854105166,3.043742714820175,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-530/M,TOPCO SOLAR INC,Mono-c-Si,0,530.0,496.3,2.56,,,72.0,13.65,49.4,12.91,41.1,0.006006,-0.1192516,45.84,1.7615037898086636,13.660993575081516,8.914922631050859e-12,0.21530738881063527,267.3330419180575,8.708043673062718,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-535/M,TOPCO SOLAR INC,Mono-c-Si,0,535.0,501.1,2.56,,,72.0,13.71,49.6,12.96,41.3,0.006032399999999999,-0.11973440000000002,45.84,1.7697535652342493,13.721457500828324,9.107932581062545e-12,0.21224505209899505,253.97157795492197,8.862287962876529,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-540/M,TOPCO SOLAR INC,Mono-c-Si,0,540.0,505.9,2.56,,,72.0,13.77,49.8,13.02,41.5,0.006058799999999999,-0.1202172,45.84,1.7773760135570378,13.781156398124594,9.220236719014613e-12,0.2092484072237751,258.2688915327224,8.931653280901935,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-545/M,TOPCO SOLAR INC,Mono-c-Si,0,545.0,510.7,2.56,,,72.0,13.83,50.0,13.07,41.7,0.0060852,-0.1207,45.84,1.7856270181716236,13.841597217384084,9.417168281090002e-12,0.20623499946794324,245.94089747265346,9.083940628232718,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +TOPCO SOLAR INC TPM7-SHDB144-550/M,TOPCO SOLAR INC,Mono-c-Si,0,550.0,515.6,2.56,,,72.0,13.89,50.2,13.13,41.9,0.006111599999999999,-0.12118280000000001,45.84,1.7932485065875219,13.901295983953075,9.5311226804232e-12,0.20329173349191756,249.97576125144317,9.15173694717144,-0.3197,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 385DE11,Topsun Co Ltd,Mono-c-Si,1,385.0,358.9,1.93,,,54.0,13.52,36.72,12.65,30.44,0.0048671999999999995,-0.0910656,46.9,1.3046643728029956,13.543034045151662,7.882275908635481e-12,0.17273037682848377,101.38534865863383,4.980100259874282,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 390DE11,Topsun Co Ltd,Mono-c-Si,1,390.0,363.7,1.93,,,54.0,13.61,36.85,12.73,30.64,0.0048996,-0.091388,46.9,1.311426343140762,13.632572319246549,8.302626644257923e-12,0.16389302103813574,98.81944325851849,5.372223857361385,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 390DE13,Topsun Co Ltd,Mono-c-Si,0,390.0,360.9,1.93,,,54.0,13.6,36.81,12.83,30.4,0.005168,-0.09762012,46.73,1.3650703967035729,13.612014426481453,2.6109433481441903e-11,0.17141156934307517,194.03317501761623,8.037213270621239,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 390DE14,Topsun Co Ltd,Mono-c-Si,0,390.0,358.8,1.93,,,54.0,13.5,36.54,12.82,30.42,0.00621,-0.1008504,47.5,1.3879834934395288,13.503850787126767,4.953478965315518e-11,0.1444058550062292,506.2547100992174,9.227222506518219,-0.369,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 395DE11,Topsun Co Ltd,Mono-c-Si,1,395.0,368.5,1.93,,,54.0,13.7,36.98,12.81,30.84,0.004931999999999999,-0.09171039999999998,46.9,1.318187700051062,13.722047168350398,8.740866780156953e-12,0.15516873164520875,96.42107294273839,5.76150153249017,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 395DE13,Topsun Co Ltd,Mono-c-Si,0,395.0,365.6,1.93,,,54.0,13.71,36.94,12.92,30.57,0.0052098,-0.09796488,46.73,1.3720222073205768,13.722971297602829,2.740637545253245e-11,0.1650143476210528,174.41175088341876,8.39673383080809,-0.3571,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 395DE14,Topsun Co Ltd,Mono-c-Si,0,395.0,363.6,1.93,,,54.0,13.55,36.74,12.88,30.63,0.006233000000000001,-0.1014024,47.5,1.3959391909035854,13.553015907381301,5.0105897232740357e-11,0.14083311029782378,632.7411607718363,9.292025859211904,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 400DE11,Topsun Co Ltd,Mono-c-Si,1,400.0,373.3,1.93,,,54.0,13.79,37.07,12.9,31.01,0.004964399999999999,-0.0919336,46.9,1.32310359805635,13.810725153489155,9.124979451931758e-12,0.14613739467925005,97.23617617213263,6.075872618523956,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 400DE13,Topsun Co Ltd,Mono-c-Si,0,400.0,370.4,1.93,,,54.0,13.79,37.03,13.03,30.71,0.0052401999999999995,-0.09820356,46.73,1.3750949874877019,13.800074199055606,2.7501035481798503e-11,0.15878127862195013,217.34670915385206,8.364904316448886,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 400DE14,Topsun Co Ltd,Mono-c-Si,0,400.0,368.3,1.93,,,54.0,13.6,36.94,12.96,30.84,0.006256,-0.10195440000000001,47.5,1.3995870978914378,13.601000378550427,4.6815614649354476e-11,0.1379602576522344,1875.5497542232642,8.651741773774383,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 405DE11,Topsun Co Ltd,Mono-c-Si,1,405.0,378.1,1.93,,,54.0,13.87,37.23,12.98,31.21,0.004993199999999999,-0.09233039999999999,46.9,1.3299481783943552,13.889767922533183,9.40234718455068e-12,0.14011929435292797,98.31354875474833,6.284214365032544,-0.32,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 405DE13,Topsun Co Ltd,Mono-c-Si,0,405.0,375.2,1.93,,,54.0,13.86,37.15,13.13,30.86,0.0052668,-0.09852179999999999,46.73,1.3789845927791873,13.867428896432132,2.7415137575428388e-11,0.15418972274561438,287.6698586381442,8.282130965200185,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 405DE14,Topsun Co Ltd,Mono-c-Si,0,405.0,373.1,1.93,,,54.0,13.65,37.14,13.05,31.03,0.006279000000000001,-0.10250640000000001,47.5,1.4115491943865222,13.65006985941657,5.106740190828128e-11,0.13542353117133768,26460.78290974756,9.379997051812856,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 410DE11,Topsun Co Ltd,Mono-c-Si,1,410.0,382.9,1.93,,,54.0,13.95,37.32,13.04,31.45,0.005021999999999999,-0.09255360000000001,46.9,1.3373388267929238,13.968923971639358,1.0301653401089682e-11,0.12515594993823734,92.25999372190951,7.036127729470942,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 410DE13,Topsun Co Ltd,Mono-c-Si,0,410.0,379.9,1.93,,,54.0,13.94,37.23,13.22,31.03,0.005297199999999999,-0.09873395999999998,46.73,1.3835731033149834,13.946268868831952,2.8483137380487656e-11,0.1446860603969464,321.7364673293911,8.563276882364033,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 410DE14,Topsun Co Ltd,Mono-c-Si,0,410.0,377.8,1.93,,,54.0,13.7,37.34,13.12,31.23,0.0063019999999999994,-0.10305840000000002,47.5,1.3982157695455526,13.700003451664731,3.4568705471148556e-11,0.13634757662400557,541192.2641287751,5.952588816389665,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 415DE13,Topsun Co Ltd,Mono-c-Si,0,415.0,384.7,1.93,,,54.0,14.02,37.38,13.31,31.19,0.005327599999999999,-0.09913176,46.73,1.3892249023638876,14.025280845986826,2.8722234554478926e-11,0.14148410270952197,375.6229891721826,8.582029243737379,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 415DE14,Topsun Co Ltd,Mono-c-Si,0,415.0,382.6,1.93,,,54.0,14.02,37.38,13.31,31.19,0.0064491999999999996,-0.10316880000000002,47.5,1.4217504163301242,14.024236196716902,5.3214925413634634e-11,0.13610419960667255,450.4467271740629,9.528487688646,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 435DE11,Topsun Co Ltd,Mono-c-Si,1,435.0,402.6,2.14,,,60.0,13.66,41.02,12.91,33.76,0.006147,-0.11239480000000003,46.8,1.5283404165742465,13.669942710338047,2.983261319833821e-11,0.19878882612707044,273.1101794805922,5.5411048153583184,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 440DE11,Topsun Co Ltd,Mono-c-Si,1,440.0,407.3,2.14,,,60.0,13.71,41.11,13.01,33.89,0.0061695,-0.11264140000000002,46.8,1.5300135304123117,13.715394382446126,2.920640691168666e-11,0.193658781660064,492.19016105360186,5.31226097721679,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 440DE13,Topsun Co Ltd,Mono-c-Si,0,440.0,408.5,2.14,,,60.0,13.7,40.97,12.96,33.95,0.006836299999999999,-0.10607133,46.85,1.5108763508022927,13.709240323935967,2.2672937364150015e-11,0.18087693971732882,268.1740010474318,9.190299775805084,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 440DE14,Topsun Co Ltd,Mono-c-Si,0,440.0,407.4,2.14,,,60.0,13.7,40.97,12.96,33.95,0.008219999999999998,-0.10570260000000001,47.3,1.5322804338021832,13.708470119890237,3.313631383741183e-11,0.17724209842336486,286.680332390674,12.863874593362834,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 445DE11,Topsun Co Ltd,Mono-c-Si,1,445.0,412.1,2.14,,,60.0,13.79,41.18,13.11,34.0,0.006205499999999999,-0.11283320000000001,46.8,1.5324788774598959,13.79343904524755,2.936363172084547e-11,0.18832624065788045,755.1569618256545,5.301171523721311,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 445DE13,Topsun Co Ltd,Mono-c-Si,0,445.0,413.3,2.14,,,60.0,13.77,41.08,13.05,34.1,0.00687123,-0.10635612000000001,46.85,1.514937322973964,13.777329463675533,2.283557009517279e-11,0.17533995541602146,329.41443410124185,9.201097219645106,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 445DE14,Topsun Co Ltd,Mono-c-Si,0,445.0,412.2,2.14,,,60.0,13.77,41.08,13.05,34.1,0.008261999999999999,-0.10598640000000001,47.3,1.4860935466933407,13.77833862278268,1.347865868534081e-11,0.18023909429518678,297.63816045266213,4.848578299678628,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 450DE11,Topsun Co Ltd,Mono-c-Si,1,450.0,416.9,2.14,,,60.0,13.86,41.3,13.2,34.15,0.0062369999999999995,-0.113162,46.8,1.536811485983431,13.86161403491935,2.9501151362860935e-11,0.1835422650884398,1576.109637183045,5.290779039798459,-0.356,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 450DE13,Topsun Co Ltd,Mono-c-Si,0,450.0,418.1,2.14,,,60.0,13.83,41.15,13.15,34.22,0.00690117,-0.10653735,46.85,1.5165409210992122,13.834073802504342,2.2620561793358046e-11,0.16963008412690683,575.8708500613857,9.064807881445654,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 450DE14,Topsun Co Ltd,Mono-c-Si,0,450.0,417.0,2.14,,,60.0,13.83,41.15,13.15,34.22,0.008298,-0.106167,47.3,1.5347655644451361,13.830005209598177,3.131664408041235e-11,0.16672373029164003,442613.3302150908,10.793816138401363,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TSH-S450SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,450.0,392.3,2.61,,,25.0,4.5,126.32,4.28,105.08,0.00171,-0.45374144,52.3,5.327381230741835,4.508747682102483,2.27136257312851e-10,1.2513613761139946,1000000.0010470537,3.560647610960947,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S450SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,450.0,395.2,2.61,,,50.0,9.01,63.16,8.56,52.54,0.007208,-0.11779339999999999,49.8,2.6322297929953162,9.01254965978987,3.4198489276785305e-10,0.3207295756633822,999999.9604499149,95.7313909297831,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 455DE11,Topsun Co Ltd,Mono-c-Si,1,455.0,421.7,2.14,,,60.0,13.92,41.51,13.27,34.34,0.006264,-0.1137374,46.8,1.544288978448613,13.920622455963974,2.948779994613895e-11,0.1822997100761118,4076.7763278042207,5.246111501609402,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 455DE13,Topsun Co Ltd,Mono-c-Si,0,455.0,422.8,2.14,,,60.0,13.9,41.28,13.27,34.29,0.006936100000000001,-0.10687392000000001,46.85,1.502096575084042,13.900475170834712,1.613154458633003e-11,0.1753939151256184,5130.735261704448,6.047809288657064,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 455DE14,Topsun Co Ltd,Mono-c-Si,0,455.0,421.7,2.14,,,60.0,13.9,41.28,13.27,34.29,0.00834,-0.1065024,47.3,1.5399271139486277,13.900081225056011,3.17010456184387e-11,0.1691223916055412,28941.8640279377,12.28993926592379,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TSH-S455SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,455.0,396.9,2.61,,,25.0,4.54,126.57,4.32,105.29,0.0017252,-0.45463944000000006,52.3,5.337889741669847,4.550873494315116,2.2922291530845495e-10,1.2417241385582118,999999.9958552563,3.5595517399523593,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S455SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,455.0,399.7,2.61,,,50.0,9.09,63.29,8.64,52.65,0.007272,-0.11803585,49.8,2.637680282402792,9.096747901661967,3.452824290523413e-10,0.3181678950071096,999999.9920623581,95.73616458436514,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 460DE13,Topsun Co Ltd,Mono-c-Si,0,460.0,427.6,2.14,,,60.0,13.99,41.45,13.37,34.41,0.00698101,-0.10731405000000002,46.85,1.5240581527597694,13.990002435201758,2.159012800687927e-11,0.1740610921988705,999999.5061501015,8.532497268526969,-0.3425,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TSH-S460SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,460.0,401.4,2.61,,,25.0,4.59,126.81,4.36,105.49,0.0017441999999999998,-0.45550152000000005,52.3,5.348362523886722,4.593022261512717,2.3170640504421214e-10,1.232403798194653,999999.985418591,3.571783054255041,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S460SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,460.0,404.3,2.61,,,50.0,9.17,63.41,8.72,52.75,0.0073360000000000005,-0.11825965,49.8,2.642681337177526,9.180973275291098,3.4847911920852126e-10,0.31582463731062715,999999.9920968682,95.73618964873397,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S465SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,465.0,406.0,2.61,,,25.0,4.63,127.04,4.4,105.68,0.0017594,-0.45632768000000007,52.3,5.357936931409248,4.635160978766397,2.337017810151669e-10,1.2238114505685196,1000000.0010986108,3.567327109053552,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S465SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,465.0,408.9,2.61,,,50.0,9.25,63.52,8.8,52.84,0.0074,-0.11846480000000002,49.8,2.6472329470993397,9.265226380334605,3.5157269087115467e-10,0.3136938476903336,999999.9921278069,95.73149168507705,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S470SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,470.0,410.5,2.61,,,25.0,4.67,127.3,4.44,105.9,0.0017745999999999999,-0.4572616,52.3,5.36891302838643,4.67728000231773,2.3583642325446494e-10,1.2143370877739041,1000000.001117347,3.5679109865333034,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S470SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,470.0,413.5,2.61,,,50.0,9.34,63.65,8.88,52.95,0.0074719999999999995,-0.11870724999999999,49.8,2.652691677285472,9.349425166142048,3.548989530005255e-10,0.31126279151013464,999999.9921642969,95.73734039930754,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S475SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,475.0,415.1,2.61,,,25.0,4.71,127.44,4.48,106.02,0.0017898,-0.45776448000000003,52.3,5.374824704882508,4.719399393267091,2.379676979820826e-10,1.2039417706689424,1000000.0011268222,3.5683656473632843,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S475SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,475.0,418.1,2.61,,,50.0,9.42,63.72,8.96,53.01,0.007536000000000001,-0.1188378,49.8,2.6556400556405935,9.43362362827719,3.5819555111055826e-10,0.3085973653158661,999999.9921850188,95.74184670559072,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S480SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,480.0,419.6,2.61,,,25.0,4.75,127.63,4.52,106.17,0.001805,-0.45844696,52.3,5.382535831610441,4.761564810812848,2.397744746782746e-10,1.1971847008879137,999999.9966774068,3.557452034226197,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S480SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,480.0,422.6,2.61,,,50.0,9.51,63.81,9.06,53.09,0.007608,-0.11900565,49.8,2.6594787478564017,9.538820372254197,3.6247688650467943e-10,0.30497573297370634,999999.9614816325,95.75459857003972,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S485SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,485.0,424.2,2.61,,,25.0,4.8,127.79,4.56,106.31,0.001824,-0.45902168000000004,52.3,5.389797798345092,4.803687219524933,2.4244357618606067e-10,1.1862539461024633,999999.981435362,3.57560255866512,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S485SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,485.0,427.2,2.61,,,50.0,9.59,63.9,9.12,53.16,0.007672,-0.1191735,49.8,2.663148134874368,9.60207627877276,3.64612350553191e-10,0.30400754508544636,999999.0246703655,95.7427336303159,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S490SB2BK(X),Topsun Co Ltd,Mono-c-Si,0,490.0,428.8,2.61,,,25.0,4.84,127.95,4.6,106.44,0.0018391999999999998,-0.45959640000000007,52.3,5.396375946240048,4.84583308361357,2.443879507286138e-10,1.178237723969279,1000000.0011622327,3.569556142817066,-0.4637,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TSH-S490SB2BK(X)5,Topsun Co Ltd,Mono-c-Si,0,490.0,431.8,2.61,,,50.0,9.68,63.97,9.21,53.22,0.007744,-0.11930405000000001,49.8,2.666096202592344,9.696802244679457,3.683110466122508e-10,0.30114748139336545,999999.9922556962,95.74717506039264,-0.485,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 495,Topsun Co Ltd,Mono-c-Si,0,495.0,439.6,2.59,,,50.0,9.77,64.05,9.29,53.28,0.00584246,-0.10587465,49.4,2.599480142034388,9.770019771974304,1.9456293193193416e-10,0.31596170544107754,156131.3513431051,100.00000099087465,-0.4672,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 500,Topsun Co Ltd,Mono-c-Si,0,500.0,444.2,2.59,,,50.0,9.86,64.11,9.37,53.33,0.005896279999999999,-0.10597383,49.4,2.6092063389122258,9.860274265822694,2.0568325239429448e-10,0.31818291307611646,11438.862354632352,100.00000099251461,-0.4672,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 505,Topsun Co Ltd,Mono-c-Si,0,505.0,448.9,2.59,,,50.0,9.95,64.17,9.46,53.38,0.005950099999999999,-0.10607301000000001,49.4,2.6102391771128266,9.95002503360278,2.0821755452400755e-10,0.31123543635515555,123707.66522146125,100.0000009994473,-0.4672,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 510,Topsun Co Ltd,Mono-c-Si,0,510.0,453.5,2.59,,,50.0,10.04,64.22,9.55,53.43,0.006003919999999999,-0.10615566,49.4,2.5873134314206894,10.04001722843537,1.6674260628125116e-10,0.311522409454106,181546.56578671766,100.00000099053261,-0.4672,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 515,Topsun Co Ltd,Mono-c-Si,0,515.0,458.1,2.59,,,50.0,10.13,64.27,9.63,53.46,0.006057740000000001,-0.10623830999999999,49.4,2.6151399447698536,10.130060685541661,2.1029574895814707e-10,0.31088446812539716,51895.14770689697,100.00000099219386,-0.4672,N,2025.7.3,6/23/2025,2.0,first_pass +Topsun Co Ltd TOP CLASS 515CH12,Topsun Co Ltd,Mono-c-Si,1,515.0,477.1,2.48,,,72.0,13.28,48.9,12.53,41.09,0.00632128,-0.1387782,45.63,1.8895489063307036,13.287758078672155,7.556216582145304e-11,0.1578193535775673,270.1494978510054,10.042516121719178,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 520CH12,Topsun Co Ltd,Mono-c-Si,1,520.0,481.9,2.48,,,72.0,13.32,49.1,12.6,41.26,0.006340320000000001,-0.13934580000000002,45.63,1.894863994283336,13.326010897682876,7.355418836452855e-11,0.15818846285619273,350.5417141823403,9.766052383876422,-0.3745,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 525CH12,Topsun Co Ltd,Mono-c-Si,1,525.0,486.7,2.48,,,72.0,13.4,49.3,12.67,41.43,0.006378400000000001,-0.1399134,45.63,1.9030592341778043,13.406353206860716,7.443834765192039e-11,0.15764303226021384,332.4961282999233,9.82079736581655,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 525DE11,Topsun Co Ltd,Mono-c-Si,1,525.0,489.5,2.56,,,72.0,13.65,49.16,12.81,40.97,0.008736,-0.1312572,46.3,1.8327328394170705,13.665697176308665,2.999843411379682e-11,0.195083684949204,169.6414860657994,8.165511212314417,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 530CH12,Topsun Co Ltd,Mono-c-Si,1,530.0,491.4,2.48,,,72.0,13.48,49.5,12.74,41.6,0.0064164800000000004,-0.140481,45.63,1.9112536461856537,13.486694501483605,7.532586001083441e-11,0.15710384511437056,316.3431788950465,9.875001327087878,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 530DE11,Topsun Co Ltd,Mono-c-Si,1,530.0,494.3,2.56,,,72.0,13.71,49.28,12.89,41.12,0.0087744,-0.13157760000000002,46.3,1.8366995994648063,13.723857155043303,2.996939906693406e-11,0.1904069178217229,188.38490671659784,8.111403506822997,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 530DE13,Topsun Co Ltd,Mono-c-Si,0,530.0,497.3,2.56,,,72.0,13.71,49.25,12.91,41.06,0.007389690000000001,-0.129429,46.54,1.7496068583595727,13.725403925265818,8.016653093252396e-12,0.20805574957881343,185.17645882228192,-1.217404015138596,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 530DE14,Topsun Co Ltd,Mono-c-Si,0,530.0,494.9,2.56,,,72.0,13.71,49.25,12.91,41.06,0.0087744,-0.1265725,47.1,1.7628083941835586,13.724950836261932,9.901249745458868e-12,0.20575375608162041,188.6773391030004,2.647934635972616,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 535CH12,Topsun Co Ltd,Mono-c-Si,1,535.0,496.2,2.48,,,72.0,13.57,49.7,12.81,41.76,0.006459320000000001,-0.14104860000000002,45.63,1.9199227768290557,13.577586034331217,7.6698720049028e-11,0.15724784179982068,281.28705520888826,9.981138808078176,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 535DE11,Topsun Co Ltd,Mono-c-Si,1,535.0,499.0,2.56,,,72.0,13.79,49.41,12.97,41.25,0.0088256,-0.1319247,46.3,1.8417047827213253,13.803504628676357,3.022623228137383e-11,0.18792679007491161,191.89794258086494,8.133957543826854,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 535DE13,Topsun Co Ltd,Mono-c-Si,0,535.0,502.1,2.56,,,72.0,13.79,49.38,12.99,41.18,0.00743281,-0.12977064,46.54,1.7541731119700745,13.805087518642464,8.059886952931876e-12,0.20639343947297337,188.64371278118395,-1.2223097185253573,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 535DE14,Topsun Co Ltd,Mono-c-Si,0,535.0,499.7,2.56,,,72.0,13.79,49.38,12.99,41.18,0.0088256,-0.1269066,47.1,1.7976076547116466,13.80363518465705,1.592938466439993e-11,0.19888902783131834,201.14723589180315,6.6654162036726206,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 540CH12,Topsun Co Ltd,Mono-c-Si,1,540.0,501.0,2.48,,,72.0,13.66,49.9,12.88,41.93,0.006502160000000001,-0.1416162,45.63,1.9288323427271947,13.668447220002799,7.833590214238556e-11,0.15649418955396807,253.06676987828482,10.114953154733136,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 540DE13,Topsun Co Ltd,Mono-c-Si,0,540.0,506.9,2.56,,,72.0,13.85,49.51,13.07,41.32,0.007465150000000001,-0.13011228,46.54,1.7579668804823976,13.863275468403451,8.005067291061843e-12,0.20338470416180207,212.18672469143624,-1.3196969447981188,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 540DE14,Topsun Co Ltd,Mono-c-Si,0,540.0,504.5,2.56,,,72.0,13.85,49.51,13.07,41.32,0.008864,-0.1272407,47.1,1.8014905305878048,13.861891452733417,1.5824983031368813e-11,0.19590983128079692,228.17659334148857,6.563171310303353,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 545CH12,Topsun Co Ltd,Mono-c-Si,1,545.0,505.8,2.48,,,72.0,13.75,50.1,12.95,42.1,0.006545000000000001,-0.1421838,45.63,1.9377412920691357,13.75930461700889,7.99934784110846e-11,0.15574880529949234,230.15951291652797,10.247622033906786,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 545DE11,Topsun Co Ltd,Mono-c-Si,1,545.0,508.6,2.56,,,72.0,13.93,49.68,13.12,41.55,0.0089152,-0.1326456,46.3,1.8522056027530325,13.94207334117342,3.077221138060784e-11,0.1806485521625022,208.4289933915517,8.19748948819619,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 545DE13,Topsun Co Ltd,Mono-c-Si,0,545.0,511.7,2.56,,,72.0,13.93,49.64,13.15,41.46,0.007508270000000001,-0.13045392,46.54,1.7629622414351291,13.942892822281111,8.102933836801266e-12,0.20003065096201308,216.12234415099903,-1.2690675727615144,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 545DE14,Topsun Co Ltd,Mono-c-Si,0,545.0,509.3,2.56,,,72.0,13.93,49.64,13.15,41.46,0.0089152,-0.12757480000000002,47.1,1.806611881914949,13.941525024402127,1.6016663193726067e-11,0.19257622145231656,232.7619180388031,6.616705907490754,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 550CH12,Topsun Co Ltd,Mono-c-Si,1,550.0,510.6,2.48,,,72.0,13.84,50.3,13.01,42.27,0.00658784,-0.1427514,45.63,1.9474150073514973,13.850699668266337,8.243030213619652e-11,0.15489490671630007,200.35626280115588,10.464818475815834,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 550DE13,Topsun Co Ltd,Mono-c-Si,0,550.0,516.5,2.56,,,72.0,14.0,49.77,13.23,41.59,0.0075460000000000015,-0.13079556,46.54,1.7671538954608879,14.01187325064346,8.09823584021768e-12,0.19776867995410008,233.193215469872,-1.3184194471876907,-0.3005,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 550DE14,Topsun Co Ltd,Mono-c-Si,0,550.0,514.1,2.56,,,72.0,14.0,49.77,13.23,41.59,0.008960000000000001,-0.12790890000000002,47.1,1.8109049318376145,14.010543714117881,1.600945100597173e-11,0.19034112003735468,252.73595765617506,6.564945328339631,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 555CH12,Topsun Co Ltd,Mono-c-Si,1,555.0,515.4,2.48,,,72.0,13.89,50.5,13.08,42.44,0.00661164,-0.143319,45.63,1.9534474609573966,13.899483660930315,8.104561578190553e-11,0.15504676910728102,227.0852661572345,10.274382519395722,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 560CH12,Topsun Co Ltd,Mono-c-Si,1,560.0,520.2,2.48,,,72.0,13.96,50.7,13.14,42.61,0.006644960000000001,-0.1438866,45.63,1.9616812080062398,13.969843633888232,8.194573946474405e-11,0.15464372531801074,219.3119396755965,10.32987379675073,-0.3745,N,2025.7.3,6/23/2025,4.0,first_pass +Topsun Co Ltd TOP CLASS 635CH12,Topsun Co Ltd,Mono-c-Si,1,635.0,589.0,3.03,,,66.0,18.17,44.89,17.13,37.08,0.009085000000000001,-0.1306299,44.8,1.7474802299702636,18.183117391408775,1.253081294905733e-10,0.14552956728715663,201.58522716726222,8.941697880593075,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 640CH12,Topsun Co Ltd,Mono-c-Si,1,640.0,593.7,3.03,,,66.0,18.22,45.09,17.17,37.28,0.00911,-0.1312119,44.8,1.7565092306825558,18.233575912513217,1.2788341362251682e-10,0.14340162533923068,192.45687503292191,9.097872349436676,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 645CH12,Topsun Co Ltd,Mono-c-Si,1,645.0,598.5,3.03,,,66.0,18.27,45.29,17.21,37.48,0.009135,-0.1317939,44.8,1.765540033403836,18.284012055502792,1.3049078625527782e-10,0.14128251605453887,184.21506021149608,9.254106906565495,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 650CH12,Topsun Co Ltd,Mono-c-Si,1,650.0,603.3,3.03,,,66.0,18.32,45.49,17.26,37.68,0.00916,-0.1323759,44.8,1.774053692669469,18.333694701342925,1.322255516374601e-10,0.13921135092675266,186.22910892397007,9.346082816199484,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 655CH12,Topsun Co Ltd,Mono-c-Si,1,655.0,608.1,3.03,,,66.0,18.37,45.69,17.3,37.88,0.009185,-0.1329579,44.8,1.7830880088906507,18.38410030643988,1.3488342465283608e-10,0.13711291749128585,178.6318885988593,9.499687267644155,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 660CH12,Topsun Co Ltd,Mono-c-Si,1,660.0,612.9,3.03,,,66.0,18.42,45.89,17.34,38.08,0.009210000000000001,-0.1335399,44.8,1.7921251264062832,18.43448441091583,1.375750684926673e-10,0.1350236780160756,171.71124421342964,9.652289031945518,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 665CH12,Topsun Co Ltd,Mono-c-Si,1,665.0,617.7,3.03,,,66.0,18.47,46.09,17.38,38.28,0.009235,-0.1341219,44.8,1.801165023115953,18.48484737096238,1.4030062222674704e-10,0.13294356631976378,165.38064174536245,9.803905805167618,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 670CH12,Topsun Co Ltd,Mono-c-Si,1,670.0,622.5,3.03,,,66.0,18.52,46.29,17.42,38.48,0.009260000000000001,-0.1347039,44.8,1.8102076780545855,18.535189532994966,1.4306022208374227e-10,0.1308725185992355,159.5677142144405,9.954550662222,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Topsun Co Ltd TOP CLASS 675CH12,Topsun Co Ltd,Mono-c-Si,1,675.0,627.2,3.03,,,66.0,18.57,46.49,17.46,38.68,0.009285,-0.13528590000000001,44.8,1.8192530848242192,18.585511235008056,1.458540266638436e-10,0.12881047684000257,154.211487025828,10.104225278419719,-0.386,N,2025.7.3,6/23/2025,4.0,bootstrapping +Translucent Solar LLC SK9609MHVC-U-395,Translucent Solar LLC,Mono-c-Si,0,395.0,369.9,1.94,,,54.0,13.71,36.9,13.03,30.32,0.0075542100000000004,-0.112914,43.7,1.3901919454845586,13.712789311305112,4.057672810756181e-11,0.17929749260596675,881.2816158777111,-3.3641479466216184,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Translucent Solar LLC SK9609MHVC-U-400,Translucent Solar LLC,Mono-c-Si,0,400.0,374.7,1.94,,,54.0,13.78,36.98,13.15,30.42,0.00759278,-0.11315879999999999,43.7,1.3932808888272739,13.780002369865963,4.095885374924027e-11,0.17196284524657945,999993.3728430948,-3.339551890136537,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9609MHVC-U-405,Translucent Solar LLC,Mono-c-Si,0,405.0,379.5,1.94,,,54.0,13.85,37.06,13.27,30.52,0.007631350000000001,-0.11340360000000001,43.7,1.3995425280786216,13.8500173506153,4.378122415100114e-11,0.15815225238486358,126245.06625006764,-2.85656199569528,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9609MHVC-U-410,Translucent Solar LLC,Mono-c-Si,0,410.0,384.3,1.94,,,54.0,13.92,37.14,13.39,30.62,0.00766992,-0.1136484,43.7,1.4057758384631394,13.920002399372127,4.674792568248753e-11,0.1438046043844299,834174.8946760175,-2.379681738122871,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9609MHVC-U-415,Translucent Solar LLC,Mono-c-Si,0,415.0,389.1,1.94,,,54.0,14.01,37.31,13.48,30.79,0.007719510000000001,-0.11416860000000001,43.7,1.4129881286490693,14.010002357434763,4.7739309343769745e-11,0.14042026074374248,834392.6504611396,-2.2647717912631227,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9610MHVC-U-440,Translucent Solar LLC,Mono-c-Si,0,440.0,412.1,2.14,,,60.0,13.73,41.02,13.05,33.72,0.007565230000000001,-0.12552120000000003,43.7,1.5457098956465003,13.732730420181609,4.084671033586157e-11,0.19772797469870407,994.2808114377592,-3.323797923725875,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Translucent Solar LLC SK9610MHVC-U-445,Translucent Solar LLC,Mono-c-Si,0,445.0,416.9,2.14,,,60.0,13.79,41.1,13.16,33.82,0.00759829,-0.12576600000000002,43.7,1.548755050127597,13.790002620383305,4.116211455455867e-11,0.19000727036145473,999999.8830588702,-3.306484776081534,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9610MHVC-U-450,Translucent Solar LLC,Mono-c-Si,0,450.0,421.7,2.14,,,60.0,13.85,41.18,13.27,33.91,0.007631350000000001,-0.1260108,43.7,1.5546444390726433,13.850004934439063,4.342039671791471e-11,0.19080675525354948,535578.1173929584,-2.9216525022269906,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Translucent Solar LLC SK9610MHVC-U-455,Translucent Solar LLC,Mono-c-Si,0,455.0,426.6,2.14,,,60.0,13.93,41.33,13.36,34.06,0.0076754300000000004,-0.1264698,43.7,1.561482588686671,13.930004894121794,4.455061537197176e-11,0.18795642225008663,534996.2075622685,-2.764886288840815,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Translucent Solar LLC SK9610MHVC-U-460,Translucent Solar LLC,Mono-c-Si,0,460.0,431.4,2.14,,,60.0,14.01,41.48,13.45,34.2,0.007719510000000001,-0.1269288,43.7,1.5684678629551188,14.01028556728525,4.580062315481237e-11,0.1859467515856264,9122.598678731394,-2.5911118818842573,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Translucent Solar LLC SK9612MHVC-U-530,Translucent Solar LLC,Mono-c-Si,0,530.0,496.5,2.56,,,72.0,13.71,49.26,13.07,40.56,0.0075542100000000004,-0.1507356,43.7,1.8558973411704471,13.710003160360886,4.072030492258595e-11,0.230501442876551,999999.8699733586,-3.3454052702419976,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9612MHVC-U-535,Translucent Solar LLC,Mono-c-Si,0,535.0,501.3,2.56,,,72.0,13.79,49.34,13.17,40.63,0.00759829,-0.15098040000000001,43.7,1.860498316011896,13.790003077177214,4.1895762766882017e-11,0.22313265819612157,999999.8358220143,-3.1681003107016665,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9612MHVC-U-540,Translucent Solar LLC,Mono-c-Si,0,540.0,506.1,2.56,,,72.0,13.85,49.42,13.27,40.7,0.007631350000000001,-0.1512252,43.7,1.8663076861802266,13.850002920526297,4.378146607370294e-11,0.21085593428708713,999997.9386115064,-2.856571084322586,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9612MHVC-U-545,Translucent Solar LLC,Mono-c-Si,0,545.0,510.9,2.56,,,72.0,13.94,49.52,13.36,40.8,0.00768094,-0.1515312,43.7,1.870684691617212,13.9400028925779,4.4442188120097235e-11,0.20748896460190644,999993.9298367809,-2.7897108880311374,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Translucent Solar LLC SK9612MHVC-U-550,Translucent Solar LLC,Mono-c-Si,0,550.0,515.8,2.56,,,72.0,14.03,49.62,13.45,40.9,0.007730530000000001,-0.15183719999999998,43.7,1.875059829127246,14.030002864676204,4.510802130948321e-11,0.20416909236898073,999992.6444283266,-2.7233274202719366,-0.3546,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-160PEG4007,Trina Solar,Multi-c-Si,0,160.0,140.7,1.644736,1.658,0.992,72.0,8.58,24.9,8.0,20.0,0.00255684,-0.0897396,46.7,1.0574243046078828,8.591904174566261,5.008129558572892e-10,0.2276050117091287,164.04761441142946,4.590968981185552,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-165DA01,Trina Solar,Mono-c-Si,0,165.0,149.2,1.262348,1.574,0.802,72.0,5.2,43.2,4.65,35.6,0.00156,-0.13824000000000003,45.5,1.7869043859112266,5.221877139094352,1.5305228703113654e-10,0.46840923037750787,111.33668058747095,11.73011395342399,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-165PEG4007,Trina Solar,Multi-c-Si,0,165.0,145.1,1.644736,1.658,0.992,72.0,8.72,25.1,8.17,20.2,0.0025985600000000006,-0.0904604,46.7,1.0643527180768275,8.727818935799036,4.944018196887872e-10,0.2201943534974383,245.5699123094094,4.329495339531243,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-170DA01,Trina Solar,Mono-c-Si,0,170.0,153.8,1.262348,1.574,0.802,72.0,5.25,43.6,4.76,35.8,0.0015749999999999998,-0.13952,45.5,1.7851099471147016,5.268518637866587,1.2261449738955082e-10,0.5056804565410312,143.35948875565953,9.61912624653578,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-170PEG4007,Trina Solar,Multi-c-Si,0,170.0,149.6,1.644736,1.658,0.992,72.0,8.86,25.3,8.33,20.4,0.00264028,-0.0911812,46.7,1.0720399344174179,8.864964743878192,4.955781052453734e-10,0.21301080915654885,380.13575776044877,4.203626541751857,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-175DA01,Trina Solar,Mono-c-Si,0,175.0,158.5,1.262348,1.574,0.802,72.0,5.3,43.9,4.85,36.2,0.0015899999999999998,-0.14048,45.5,1.792407761856467,5.314109234823496,1.1689339302733282e-10,0.46992196333882524,176.52172488547515,9.08248065688004,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-175PEG4007,Trina Solar,Multi-c-Si,0,175.0,154.1,1.644736,1.658,0.992,72.0,9.0,25.4,8.5,20.6,0.002682,-0.0915416,46.7,1.0773092383369696,9.00150891713538,5.173465317593459e-10,0.1940908771905444,1157.6648471623146,4.4181091184429935,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-180DA01,Trina Solar,Mono-c-Si,0,180.0,163.1,1.262348,1.574,0.802,72.0,5.35,44.2,4.9,36.8,0.0016049999999999999,-0.14144,45.5,1.813839315564117,5.361549912051548,1.3357793735266668e-10,0.3845315503917579,178.11770565478247,10.175704559539355,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-185DA01,Trina Solar,Mono-c-Si,0,185.0,164.3,1.262348,1.574,0.802,72.0,5.4,44.5,4.95,37.5,0.002117769175676706,-0.1632921525316151,45.8,2.0226040603874975,5.4053048616584345,1.4441686973472446e-09,0.19768209669796738,201.22740099662224,16.158868953818157,-0.5081898621086535,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-185DA01A,Trina Solar,Mono-c-Si,0,185.0,166.7,1.262348,1.574,0.802,72.0,5.48,44.6,5.14,36.1,0.0027400000000000007,-0.1561,45.3,1.8749849915350318,5.484590792134916,2.5324716665497754e-10,0.5836534451220063,696.7036581645486,5.452547229200924,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-185DA01A05,Trina Solar,Mono-c-Si,0,185.0,166.4,1.262348,1.574,0.802,72.0,5.48,44.6,5.14,36.1,0.0021920000000000004,-0.15164000000000002,45.7,1.8560800841810914,5.484895278942385,1.9864548312615465e-10,0.5912396838594146,661.860974118472,6.587201439496548,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-185DA01A08,Trina Solar,Mono-c-Si,0,185.0,166.7,1.262348,1.574,0.802,72.0,5.48,44.6,5.14,36.1,0.0027400000000000007,-0.1561,45.3,1.8749849915350318,5.484590792134916,2.5324716665497754e-10,0.5836534451220063,696.7036581645486,5.452547229200924,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-190DA01A,Trina Solar,Mono-c-Si,0,190.0,171.4,1.262348,1.574,0.802,72.0,5.52,45.1,5.18,36.8,0.0027600000000000003,-0.15785,45.3,1.9044335099286729,5.524190553886347,2.8331331311338265e-10,0.5186647971259086,683.21048308654,6.350923693104398,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-190DA01A05,Trina Solar,Mono-c-Si,0,190.0,171.0,1.262348,1.574,0.802,72.0,5.52,45.1,5.18,36.8,0.002208,-0.15334,45.7,1.8851233799902594,5.524468136195449,2.2216311118350457e-10,0.5264007745046018,650.3232393946271,7.490375426295347,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-190DA01A08,Trina Solar,Mono-c-Si,0,190.0,171.4,1.262348,1.574,0.802,72.0,5.52,45.1,5.18,36.8,0.0027600000000000003,-0.15785,45.3,1.9044335099286729,5.524190553886347,2.8331331311338265e-10,0.5186647971259086,683.21048308654,6.350923693104398,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-195DA01A,Trina Solar,Mono-c-Si,0,195.0,176.0,1.262348,1.574,0.802,72.0,5.56,45.6,5.22,37.4,0.00278,-0.1596,45.3,1.9308325156496995,5.56385428566636,3.044731949897636e-10,0.4773530155210243,688.6057464322372,6.909287846074484,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-195DA01A05,Trina Solar,Mono-c-Si,0,195.0,175.6,1.262348,1.574,0.802,72.0,5.56,45.6,5.22,37.4,0.002224,-0.15504,45.7,1.911189199555339,5.564114407076425,2.387198308646601e-10,0.4851918501204247,655.6636526370658,8.051917310634819,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-195DA01A08,Trina Solar,Mono-c-Si,0,195.0,176.0,1.262348,1.574,0.802,72.0,5.56,45.6,5.22,37.4,0.00278,-0.1596,45.3,1.9308325156496995,5.56385428566636,3.044731949897636e-10,0.4773530155210243,688.6057464322372,6.909287846074484,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-200DA01A,Trina Solar,Mono-c-Si,0,200.0,180.6,1.262348,1.574,0.802,72.0,5.62,46.2,5.26,38.2,0.00281,-0.1617,45.3,1.968861382945029,5.6246283654258376,3.564314078596802e-10,0.40857457342287956,496.11240283496124,8.19986420472107,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-200DA01A05,Trina Solar,Mono-c-Si,0,200.0,180.2,1.262348,1.574,0.802,72.0,5.62,46.2,5.26,38.2,0.002248,-0.15708000000000003,45.7,1.9486938896851438,5.624886372140894,2.794279626083546e-10,0.4166150339201308,479.1646510819794,9.352466480032987,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-200DA01A08,Trina Solar,Mono-c-Si,0,200.0,180.6,1.262348,1.574,0.802,72.0,5.62,46.2,5.26,38.2,0.00281,-0.1617,45.3,1.968861382945029,5.6246283654258376,3.564314078596802e-10,0.40857457342287956,496.11240283496124,8.19986420472107,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-205DA01A,Trina Solar,Mono-c-Si,0,205.0,185.3,1.262348,1.574,0.802,72.0,5.66,46.6,5.32,38.6,0.0028300000000000005,-0.1631,45.3,1.983310874906975,5.663122315727622,3.498084384247337e-10,0.3954095195716076,716.781581440369,7.9588630936842995,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-205DA01A05,Trina Solar,Mono-c-Si,0,205.0,184.9,1.262348,1.574,0.802,72.0,5.66,46.6,5.32,38.6,0.0022640000000000004,-0.15844000000000003,45.7,1.963013288561868,5.663348166770663,2.742069937450609e-10,0.4034138539612152,681.9620948503714,9.107932549977354,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-205DA01A08,Trina Solar,Mono-c-Si,0,205.0,185.3,1.262348,1.574,0.802,72.0,5.66,46.6,5.32,38.6,0.0028300000000000005,-0.1631,45.3,1.983310874906975,5.663122315727622,3.498084384247337e-10,0.3954095195716076,716.781581440369,7.9588630936842995,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220DA05,Trina Solar,Mono-c-Si,0,220.0,193.7,1.618355,1.643,0.985,60.0,8.0,36.8,7.39,29.8,0.0027760000000000003,-0.1385152,46.3,1.6422528774408645,8.01472755377929,1.4449499882399586e-09,0.30367316902211644,164.95517154884658,9.669129899136022,-0.5222,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA05,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0505,Trina Solar,Multi-c-Si,0,220.0,199.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.004775085,-0.12135168,45.0,1.4931049543111696,8.164388427871232,1.5862524582911158e-10,0.45530257931545526,257.8958941718703,4.336407672192068,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0508,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0510,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0515,Trina Solar,Multi-c-Si,0,220.0,199.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.004775085,-0.12135168,45.0,1.4931049543111696,8.164388427871232,1.5862524582911158e-10,0.45530257931545526,257.8958941718703,4.336407672192068,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0518,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0520,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0528,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0530,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PA0538,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PD05,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PD0508,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PD0510,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-220PD0518,Trina Solar,Multi-c-Si,0,220.0,197.5,1.618355,1.643,0.985,60.0,8.15,36.8,7.6,29.0,0.0040750000000000005,-0.11408,46.1,1.503925499137825,8.163918216899283,1.894805180018104e-10,0.45240836590197403,264.91387788782396,12.745289328255016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA05,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0505,Trina Solar,Multi-c-Si,0,225.0,204.2,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.00480438,-0.12168144,45.0,1.5052979802242745,8.212169327377453,1.8246835620476176e-10,0.40402737907666086,272.2438876699965,5.4685860237721675,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0508,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0510,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0515,Trina Solar,Multi-c-Si,0,225.0,204.2,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.00480438,-0.12168144,45.0,1.5052979802242745,8.212169327377453,1.8246835620476176e-10,0.40402737907666086,272.2438876699965,5.4685860237721675,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0518,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0520,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0528,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0530,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PA0538,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PD05,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PD0508,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PD0510,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-225PD0518,Trina Solar,Multi-c-Si,0,225.0,202.1,1.618355,1.643,0.985,60.0,8.2,36.9,7.66,29.4,0.0040999999999999995,-0.11438999999999999,46.1,1.5160810166818108,8.211757186974493,2.1731058197551296e-10,0.40114096538808136,279.7741079515942,13.939831402311016,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230DA05,Trina Solar,Mono-c-Si,0,230.0,202.8,1.618355,1.643,0.985,60.0,8.18,37.0,7.66,30.0,0.00283846,-0.139268,46.3,1.639668002639946,8.185748643279805,1.2830974024948312e-09,0.2946360950561477,419.2511070298036,8.37233754376899,-0.5222,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA05,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0505,Trina Solar,Multi-c-Si,0,230.0,208.8,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0048395339999999995,-0.1220112,45.0,1.5183616410218683,8.27111646589443,2.1234818158345184e-10,0.35320039186939967,262.44272069476057,6.707249426253897,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0508,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0510,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0515,Trina Solar,Multi-c-Si,0,230.0,208.8,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0048395339999999995,-0.1220112,45.0,1.5183616410218683,8.27111646589443,2.1234818158345184e-10,0.35320039186939967,262.44272069476057,6.707249426253897,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0518,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0520,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0528,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0530,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PA0538,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PD05,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PD0508,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PD0510,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-230PD0518,Trina Solar,Multi-c-Si,0,230.0,208.9,1.618355,1.643,0.985,60.0,8.26,37.0,7.72,29.8,0.0049559999999999995,-0.1295,44.1,1.5522478051799755,8.269979396154357,3.619195411432481e-10,0.3441500470216785,284.8549035301226,4.893075506889187,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA05,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0505,Trina Solar,Multi-c-Si,0,235.0,213.5,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004868829000000001,-0.12234096,45.0,1.5244038601985235,8.316416639809377,2.2163164587964566e-10,0.31911029457101064,413.2703496978518,7.007333675349302,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0508,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0510,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0515,Trina Solar,Multi-c-Si,0,235.0,213.5,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004868829000000001,-0.12234096,45.0,1.5244038601985235,8.316416639809377,2.2163164587964566e-10,0.31911029457101064,413.2703496978518,7.007333675349302,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0518,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0520,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0528,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0530,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PA0538,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PD05,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PD0508,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PD0510,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-235PD0518,Trina Solar,Multi-c-Si,0,235.0,213.6,1.618355,1.643,0.985,60.0,8.31,37.1,7.81,30.1,0.004986,-0.12985,44.1,1.5584740920517706,8.31546859539549,3.7777103534035296e-10,0.31007498106827736,471.1856808097657,5.189688386256741,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240DA05,Trina Solar,Mono-c-Si,0,240.0,211.9,1.618355,1.643,0.985,60.0,8.38,37.5,7.84,30.6,0.0029078600000000004,-0.14115,46.3,1.6691240327337646,8.386218812484543,1.4480597136281897e-09,0.26179345389951897,352.77324899344256,9.232531534809992,-0.5222,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA05,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.38,37.5,7.84,30.6,0.005028,-0.13124999999999998,44.1,1.58447281112598,8.388425137867644,4.3473678515028857e-10,0.28394992146226355,282.4287039864474,6.337224011800145,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0505,Trina Solar,Multi-c-Si,0,240.0,218.1,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.004903983,-0.12267072000000001,45.0,1.5323879521440131,8.374195562407559,2.38055305609537e-10,0.2852718607959846,569.1074880800971,7.555935515788487,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0508,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0510,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0515,Trina Solar,Multi-c-Si,0,240.0,218.1,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.004903983,-0.12267072000000001,45.0,1.5323879521440131,8.374195562407559,2.38055305609537e-10,0.2852718607959846,569.1074880800971,7.555935515788487,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0518,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0520,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.38,37.5,7.84,30.6,0.005028,-0.13124999999999998,44.1,1.58447281112598,8.388425137867644,4.3473678515028857e-10,0.28394992146226355,282.4287039864474,6.337224011800145,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0528,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0530,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PA0538,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PD05,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.38,37.5,7.84,30.6,0.005028,-0.13124999999999998,44.1,1.58447281112598,8.388425137867644,4.3473678515028857e-10,0.28394992146226355,282.4287039864474,6.337224011800145,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PD0508,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PD0510,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-240PD0518,Trina Solar,Multi-c-Si,0,240.0,218.2,1.618355,1.643,0.985,60.0,8.37,37.2,7.89,30.4,0.0050219999999999996,-0.1302,44.1,1.5667322382044515,8.373380736736163,4.0580549604882506e-10,0.2762120647300392,683.8437739975844,5.730939216580978,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA05,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0505,Trina Solar,Multi-c-Si,0,245.0,222.8,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.0049625730000000005,-0.12300048,45.0,1.5431672184774363,8.474453338833673,2.671280406251745e-10,0.2505055917978831,476.4476309598909,8.461892062483303,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0508,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0510,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0515,Trina Solar,Multi-c-Si,0,245.0,222.8,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.0049625730000000005,-0.12300048,45.0,1.5431672184774363,8.474453338833673,2.671280406251745e-10,0.2505055917978831,476.4476309598909,8.461892062483303,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0518,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0520,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0528,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0530,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PA0538,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD05,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD05001,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0500C,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0500M,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0500S,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD05051,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD05052,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0505M,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0505S,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0508,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD05081,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0508C,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0508D,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0508M,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0508S,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0510,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-245PD0518,Trina Solar,Multi-c-Si,0,245.0,222.9,1.618355,1.643,0.985,60.0,8.47,37.3,7.98,30.7,0.005082000000000001,-0.13055,44.1,1.5779157014989487,8.47369290620277,4.554229573245655e-10,0.241392810103851,553.6554839075739,6.624078779399732,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA05,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0505,Trina Solar,Multi-c-Si,0,250.0,227.4,1.618355,1.643,0.985,60.0,8.55,37.4,8.06,31.0,0.005009445,-0.12333024,45.0,1.5530177153736553,8.553927693228347,2.9470555940002406e-10,0.21724353197610252,472.90671952190996,9.243446422984187,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0508,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0510,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0515,Trina Solar,Multi-c-Si,0,250.0,227.4,1.618355,1.643,0.985,60.0,8.55,37.4,8.06,31.0,0.005009445,-0.12333024,45.0,1.5530177153736553,8.553927693228347,2.9470555940002406e-10,0.21724353197610252,472.90671952190996,9.243446422984187,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0518,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0520,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0528,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0530,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA0538,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA05A,Trina Solar,Multi-c-Si,0,250.0,229.1,1.618355,1.643,0.985,60.0,8.9,37.8,8.2,30.5,0.004450000000000001,-0.12474,43.6,1.549389516592723,8.924848298256679,2.184771083061546e-10,0.33015349389463616,118.25221275897555,6.390087479283865,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA05A08,Trina Solar,Multi-c-Si,0,250.0,229.1,1.618355,1.643,0.985,60.0,8.9,37.8,8.2,30.5,0.004450000000000001,-0.12474,43.6,1.549389516592723,8.924848298256679,2.184771083061546e-10,0.33015349389463616,118.25221275897555,6.390087479283865,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA05A10,Trina Solar,Multi-c-Si,0,250.0,229.1,1.618355,1.643,0.985,60.0,8.9,37.8,8.2,30.5,0.004450000000000001,-0.12474,43.6,1.549389516592723,8.924848298256679,2.184771083061546e-10,0.33015349389463616,118.25221275897555,6.390087479283865,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PA05A18,Trina Solar,Multi-c-Si,0,250.0,229.1,1.618355,1.643,0.985,60.0,8.9,37.8,8.2,30.5,0.004450000000000001,-0.12474,43.6,1.549389516592723,8.924848298256679,2.184771083061546e-10,0.33015349389463616,118.25221275897555,6.390087479283865,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD05,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD05001,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0500C,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0500M,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0500S,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0500U,Trina Solar,Multi-c-Si,0,250.0,227.4,1.6367999999999998,1.65,0.992,60.0,8.79,38.0,8.27,30.3,0.005150061,-0.1253088,45.0,1.545204350275292,8.795776684850432,1.8230223247706644e-10,0.3845654706479689,585.1680364229929,4.846864407118095,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0505,Trina Solar,Multi-c-Si,0,250.0,229.1,1.618355,1.643,0.985,60.0,8.79,38.0,8.27,30.3,0.004395,-0.1254,43.6,1.5301964000741537,8.796313345924368,1.4315348264207832e-10,0.38829559155546184,540.6196547536587,2.852914162855757,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD05051,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD05052,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0505M,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0505S,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0505U,Trina Solar,Multi-c-Si,0,250.0,227.4,1.6367999999999998,1.65,0.992,60.0,8.79,38.0,8.27,30.3,0.005150061,-0.1253088,45.0,1.545204350275292,8.795776684850432,1.8230223247706644e-10,0.3845654706479689,585.1680364229929,4.846864407118095,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0508,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD05081,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0508C,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0508D,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0508M,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0508S,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0508U,Trina Solar,Multi-c-Si,0,250.0,227.4,1.6367999999999998,1.65,0.992,60.0,8.79,38.0,8.27,30.3,0.005150061,-0.1253088,45.0,1.545204350275292,8.795776684850432,1.8230223247706644e-10,0.3845654706479689,585.1680364229929,4.846864407118095,-0.43224,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0510,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PD0518,Trina Solar,Multi-c-Si,0,250.0,227.5,1.618355,1.643,0.985,60.0,8.55,37.6,8.06,31.0,0.00513,-0.1316,44.1,1.5823369073229114,8.55000404320199,4.093358135749104e-10,0.2356331756947161,498413.9951669694,5.580897360749308,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PE05A,Trina Solar,Multi-c-Si,0,250.0,220.4,1.618355,1.643,0.985,60.0,8.79,38.0,8.27,30.3,0.00476418,-0.146984,47.7,1.6576577934333174,8.792063606792249,9.707933112763878e-10,0.35705929582199936,1520.9096833047563,2.252034730261783,-0.5006,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PE05A08,Trina Solar,Multi-c-Si,0,250.0,220.4,1.618355,1.643,0.985,60.0,8.79,38.0,8.27,30.3,0.00476418,-0.146984,47.7,1.6576577934333174,8.792063606792249,9.707933112763878e-10,0.35705929582199936,1520.9096833047563,2.252034730261783,-0.5006,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-250PEG507,Trina Solar,Multi-c-Si,0,250.0,222.2,1.644736,1.658,0.992,60.0,8.97,37.5,8.34,30.0,0.00267306,-0.13515,46.7,1.5911820066306117,8.985444551397597,5.119291358406217e-10,0.34488808630190154,200.30667572458395,4.410248562163206,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA05,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0505,Trina Solar,Multi-c-Si,0,255.0,233.8,1.618355,1.643,0.985,60.0,8.88,38.1,8.37,30.5,0.00444,-0.12573,43.6,1.536217837871744,8.884661909250108,1.4961232440868563e-10,0.36839314663246625,701.7150570456781,3.1294636597677523,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0508,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0510,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0518,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0520,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0528,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0530,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA0538,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA05A,Trina Solar,Multi-c-Si,0,255.0,233.8,1.618355,1.643,0.985,60.0,8.95,38.0,8.26,30.9,0.004475,-0.1254,43.6,1.5631857243381286,8.971486031464666,2.400366928381819e-10,0.29606224848204943,123.32464745294308,7.149325733201703,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA05A08,Trina Solar,Multi-c-Si,0,255.0,233.8,1.618355,1.643,0.985,60.0,8.95,38.0,8.26,30.9,0.004475,-0.1254,43.6,1.5631857243381286,8.971486031464666,2.400366928381819e-10,0.29606224848204943,123.32464745294308,7.149325733201703,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA05A10,Trina Solar,Multi-c-Si,0,255.0,233.8,1.618355,1.643,0.985,60.0,8.95,38.0,8.26,30.9,0.004475,-0.1254,43.6,1.5631857243381286,8.971486031464666,2.400366928381819e-10,0.29606224848204943,123.32464745294308,7.149325733201703,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PA05A18,Trina Solar,Multi-c-Si,0,255.0,233.8,1.618355,1.643,0.985,60.0,8.95,38.0,8.26,30.9,0.004475,-0.1254,43.6,1.5631857243381286,8.971486031464666,2.400366928381819e-10,0.29606224848204943,123.32464745294308,7.149325733201703,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD05,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD05001,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0500C,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0500M,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0500S,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0505,Trina Solar,Multi-c-Si,0,255.0,233.8,1.618355,1.643,0.985,60.0,8.88,38.1,8.37,30.5,0.00444,-0.12573,43.6,1.536217837871744,8.884661909250108,1.4961232440868563e-10,0.36839314663246625,701.7150570456781,3.1294636597677523,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD05051,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD05052,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0505M,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0505S,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0508,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD05081,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0508C,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0508D,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0508M,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0508S,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0510,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PD0518,Trina Solar,Multi-c-Si,0,255.0,232.2,1.618355,1.643,0.985,60.0,8.62,37.7,8.12,31.4,0.0051719999999999995,-0.13195,44.1,1.6060103991649808,8.62343858635893,5.455340531946483e-10,0.18598483199652857,466.23510902913836,8.044776180797113,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PE05A,Trina Solar,Multi-c-Si,0,255.0,224.9,1.618355,1.643,0.985,60.0,8.88,38.1,8.37,30.5,0.00481296,-0.1473708,47.7,1.664334702753395,8.880697507582141,1.014216401579843e-09,0.3372850187299791,4294.022062379636,2.5262971578276314,-0.5006,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PE05A08,Trina Solar,Multi-c-Si,0,255.0,224.9,1.618355,1.643,0.985,60.0,8.88,38.1,8.37,30.5,0.00481296,-0.1473708,47.7,1.664334702753395,8.880697507582141,1.014216401579843e-09,0.3372850187299791,4294.022062379636,2.5262971578276314,-0.5006,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-255PEG507,Trina Solar,Multi-c-Si,0,255.0,226.8,1.644736,1.658,0.992,60.0,9.01,37.5,8.42,30.3,0.00268498,-0.13515,46.7,1.5961220394247388,9.020079664637247,5.558347006271454e-10,0.30125090681047895,269.2819094805602,5.0521642496369585,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA05,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0505,Trina Solar,Multi-c-Si,0,260.0,238.5,1.618355,1.643,0.985,60.0,9.0,38.2,8.5,30.6,0.0045,-0.12606000000000003,43.6,1.5392674287732517,9.002781131968934,1.4959358293613515e-10,0.36163349902343916,1170.2798602888124,3.010078454464721,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0508,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0510,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0518,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0520,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0528,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0530,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA0538,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA05A,Trina Solar,Multi-c-Si,0,260.0,238.5,1.618355,1.643,0.985,60.0,9.02,38.2,8.31,31.3,0.00451,-0.12606000000000003,43.6,1.57990754365206,9.040702770327757,2.7487955548218433e-10,0.2614751237275634,113.92222810636616,8.268453251571154,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA05A08,Trina Solar,Multi-c-Si,0,260.0,238.5,1.618355,1.643,0.985,60.0,9.02,38.2,8.31,31.3,0.00451,-0.12606000000000003,43.6,1.57990754365206,9.040702770327757,2.7487955548218433e-10,0.2614751237275634,113.92222810636616,8.268453251571154,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA05A10,Trina Solar,Multi-c-Si,0,260.0,238.5,1.618355,1.643,0.985,60.0,9.02,38.2,8.31,31.3,0.00451,-0.12606000000000003,43.6,1.57990754365206,9.040702770327757,2.7487955548218433e-10,0.2614751237275634,113.92222810636616,8.268453251571154,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PA05A18,Trina Solar,Multi-c-Si,0,260.0,238.5,1.618355,1.643,0.985,60.0,9.02,38.2,8.31,31.3,0.00451,-0.12606000000000003,43.6,1.57990754365206,9.040702770327757,2.7487955548218433e-10,0.2614751237275634,113.92222810636616,8.268453251571154,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD05,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD05001,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0500C,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0500M,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0500S,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0505,Trina Solar,Multi-c-Si,0,260.0,238.5,1.618355,1.643,0.985,60.0,9.0,38.2,8.5,30.6,0.0045,-0.12606000000000003,43.6,1.5392674287732517,9.002781131968934,1.4959358293613515e-10,0.36163349902343916,1170.2798602888124,3.010078454464721,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD05051,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD05052,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0505M,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0505S,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0508,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD05081,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0508C,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0508D,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0508M,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0508S,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0510,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0518,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PD0518D,Trina Solar,Multi-c-Si,0,260.0,236.9,1.618355,1.643,0.985,60.0,8.67,37.9,8.2,31.7,0.005202,-0.13265,44.1,1.6148868538378078,8.671614715450488,5.539493126645601e-10,0.16767195067137639,900.2926022846804,8.114686430660855,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PE05A,Trina Solar,Multi-c-Si,0,260.0,229.5,1.618355,1.643,0.985,60.0,9.0,38.2,8.5,30.6,0.0048779999999999995,-0.14775760000000002,47.7,1.6685126349026005,9.010364503257353,1.0273624534903337e-09,0.33053984626918803,999999.8647419728,2.5103795440500702,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-260PE05A08,Trina Solar,Multi-c-Si,0,260.0,229.5,1.618355,1.643,0.985,60.0,9.0,38.2,8.5,30.6,0.0048779999999999995,-0.14775760000000002,47.7,1.6685126349026005,9.010364503257353,1.0273624534903337e-09,0.33053984626918803,999999.8647419728,2.5103795440500702,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-260PEG507,Trina Solar,Multi-c-Si,0,260.0,231.4,1.644736,1.658,0.992,60.0,9.1,37.6,8.52,30.5,0.0027118,-0.1355104,46.7,1.6024337832397304,9.10841397091676,5.795867401561028e-10,0.28263990012199985,305.6848925853802,5.317080772535272,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PEG540,Trina Solar,Multi-c-Si,0,260.0,236.3,1.644736,1.658,0.992,60.0,9.1,37.6,8.52,30.5,0.0056419999999999994,-0.114304,46.5,1.5077294281459992,9.11153772757316,1.323089830862054e-10,0.3057375188247163,241.14034360011289,10.576399476299569,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-260PEG547,Trina Solar,Multi-c-Si,0,260.0,236.3,1.644736,1.658,0.992,60.0,9.1,37.6,8.52,30.5,0.0056419999999999994,-0.114304,46.5,1.5077294281459992,9.11153772757316,1.323089830862054e-10,0.3057375188247163,241.14034360011289,10.576399476299569,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD061M(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD061M08(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD061M10(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD061M18(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD061MT0(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD061MT8(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD09M4C,Trina Solar,Mono-c-Si,0,265.0,245.9,1.62,,,56.0,8.81,38.5,8.36,31.7,0.0030923100000000005,-0.09829050000000002,45.52,1.389061196295175,8.81456568287209,8.030615096290586e-12,0.2988085479468963,576.584797531024,5.685014199497277,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD09M4C08,Trina Solar,Mono-c-Si,0,265.0,245.9,1.62,,,56.0,8.81,38.5,8.36,31.7,0.0030923100000000005,-0.09829050000000002,45.52,1.389061196295175,8.81456568287209,8.030615096290586e-12,0.2988085479468963,576.584797531024,5.685014199497277,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DD09M4C18,Trina Solar,Mono-c-Si,0,265.0,245.9,1.62,,,56.0,8.81,38.5,8.36,31.7,0.0030923100000000005,-0.09829050000000002,45.52,1.389061196295175,8.81456568287209,8.030615096290586e-12,0.2988085479468963,576.584797531024,5.685014199497277,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DE061M(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DE061M08(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DE061M10(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DE061M18(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DE061MT0(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265DE061MT8(II),Trina Solar,Mono-c-Si,0,265.0,244.8,1.62,,,48.0,10.33,32.8,9.78,27.1,0.0026858,-0.08692,45.68,1.2006439832965894,10.336704553248685,1.398313103649095e-11,0.20298547324203703,312.74864730242,5.250427819181408,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PA0505,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PA05A,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.07,38.3,8.39,31.6,0.004535,-0.12639,43.6,1.5868511032097052,9.086202169821224,2.896703330121014e-10,0.23069041254283365,129.14085997593807,8.666753689697797,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PA05A08,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.07,38.3,8.39,31.6,0.004535,-0.12639,43.6,1.5868511032097052,9.086202169821224,2.896703330121014e-10,0.23069041254283365,129.14085997593807,8.666753689697797,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PA05A10,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.07,38.3,8.39,31.6,0.004535,-0.12639,43.6,1.5868511032097052,9.086202169821224,2.896703330121014e-10,0.23069041254283365,129.14085997593807,8.666753689697797,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PA05A18,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.07,38.3,8.39,31.6,0.004535,-0.12639,43.6,1.5868511032097052,9.086202169821224,2.896703330121014e-10,0.23069041254283365,129.14085997593807,8.666753689697797,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05001,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05002,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0500C,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0500M,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0500S,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0505,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05051,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05052,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0505M,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0505S,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0508,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05081,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05082,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0508C,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0508D,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0508M,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0508S,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0510,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05102,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0518,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD05182,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PD0518D,Trina Solar,Multi-c-Si,0,265.0,243.2,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.00455,-0.12639,43.6,1.5452627722926775,9.101320593030236,1.5637014350040168e-10,0.3421996328927053,2358.0459578237987,3.2812427856304818,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PDG5,Trina Solar,Multi-c-Si,0,265.0,236.0,1.644736,1.658,0.992,60.0,9.2,37.6,8.6,30.8,0.0027416,-0.1355104,46.7,1.6131018994574289,9.208863641246035,6.822537239888769e-10,0.23813220215264924,247.16892708949314,6.626324674561723,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PE05A,Trina Solar,Multi-c-Si,0,265.0,234.1,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.004932199999999999,-0.14814439999999998,47.7,1.6763314120339983,9.123224428686392,1.0904322319493586e-09,0.3107597701344583,999999.9793059055,2.9040095820622636,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-265PE05A08,Trina Solar,Multi-c-Si,0,265.0,234.1,1.618355,1.643,0.985,60.0,9.1,38.3,8.61,30.8,0.004932199999999999,-0.14814439999999998,47.7,1.6763314120339983,9.123224428686392,1.0904322319493586e-09,0.3107597701344583,999999.9793059055,2.9040095820622636,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-265PEG5,Trina Solar,Multi-c-Si,0,265.0,236.0,1.644736,1.658,0.992,60.0,9.2,37.6,8.6,30.8,0.0027416,-0.1355104,46.7,1.6131018994574289,9.208863641246035,6.822537239888769e-10,0.23813220215264924,247.16892708949314,6.626324674561723,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PEG507,Trina Solar,Multi-c-Si,0,265.0,236.0,1.644736,1.658,0.992,60.0,9.2,37.6,8.6,30.8,0.0027416,-0.1355104,46.7,1.6131018994574289,9.208863641246035,6.822537239888769e-10,0.23813220215264924,247.16892708949314,6.626324674561723,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PEG540,Trina Solar,Multi-c-Si,0,265.0,241.0,1.644736,1.658,0.992,60.0,9.2,37.6,8.6,30.8,0.005704,-0.114304,46.5,1.5171723843521319,9.21181205187152,1.5576024955804894e-10,0.2614931496189357,203.66801008235993,11.954501917827356,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-265PEG547,Trina Solar,Multi-c-Si,0,265.0,241.0,1.644736,1.658,0.992,60.0,9.2,37.6,8.6,30.8,0.005704,-0.114304,46.5,1.5171723843521319,9.21181205187152,1.5576024955804894e-10,0.2614931496189357,203.66801008235993,11.954501917827356,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD05A,Trina Solar,Mono-c-Si,0,270.0,246.4,1.629856,1.643,0.992,60.0,9.23,38.6,8.77,30.8,0.0049842,-0.114256,45.8,1.5168754389897732,9.230003422067746,8.197626397126809e-11,0.37067432020148994,999996.4686652777,9.205052299471742,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270DD05A(II),Trina Solar,Mono-c-Si,0,270.0,246.4,1.629856,1.643,0.992,60.0,9.26,38.7,8.66,31.2,0.0050004,-0.114552,45.8,1.5376384679904056,9.273697610718544,1.0683490185085512e-10,0.33760736468771657,228.23282573326068,11.590697586028027,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD05A05,Trina Solar,Mono-c-Si,0,270.0,246.4,1.629856,1.643,0.992,60.0,9.23,38.6,8.77,30.8,0.0049842,-0.114256,45.8,1.5168754389897732,9.230003422067746,8.197626397126809e-11,0.37067432020148994,999996.4686652777,9.205052299471742,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270DD05A05(II),Trina Solar,Mono-c-Si,0,270.0,246.4,1.629856,1.643,0.992,60.0,9.26,38.7,8.66,31.2,0.0050004,-0.114552,45.8,1.5376384679904056,9.273697610718544,1.0683490185085512e-10,0.33760736468771657,228.23282573326068,11.590697586028027,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD05A08,Trina Solar,Mono-c-Si,0,270.0,246.4,1.629856,1.643,0.992,60.0,9.23,38.6,8.77,30.8,0.0049842,-0.114256,45.8,1.5168754389897732,9.230003422067746,8.197626397126809e-11,0.37067432020148994,999996.4686652777,9.205052299471742,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270DD05A08(II),Trina Solar,Mono-c-Si,0,270.0,246.4,1.629856,1.643,0.992,60.0,9.26,38.7,8.66,31.2,0.0050004,-0.114552,45.8,1.5376384679904056,9.273697610718544,1.0683490185085512e-10,0.33760736468771657,228.23282573326068,11.590697586028027,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD061M(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD061M08(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD061M10(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD061M18(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD061MT0(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD061MT8(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD09M4C,Trina Solar,Mono-c-Si,0,270.0,250.7,1.62,,,56.0,8.92,38.7,8.46,31.9,0.00313092,-0.09880110000000002,45.52,1.3973703790267022,8.924999702114826,8.30318112864854e-12,0.29185930227718865,520.7079088705206,5.86820460205399,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD09M4C08,Trina Solar,Mono-c-Si,0,270.0,250.7,1.62,,,56.0,8.92,38.7,8.46,31.9,0.00313092,-0.09880110000000002,45.52,1.3973703790267022,8.924999702114826,8.30318112864854e-12,0.29185930227718865,520.7079088705206,5.86820460205399,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DD09M4C18,Trina Solar,Mono-c-Si,0,270.0,250.7,1.62,,,56.0,8.92,38.7,8.46,31.9,0.00313092,-0.09880110000000002,45.52,1.3973703790267022,8.924999702114826,8.30318112864854e-12,0.29185930227718865,520.7079088705206,5.86820460205399,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DE061M(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DE061M08(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DE061M10(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DE061M18(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DE061MT0(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270DE061MT8(II),Trina Solar,Mono-c-Si,0,270.0,249.6,1.62,,,48.0,10.43,33.0,9.87,27.4,0.0027118,-0.08745000000000001,45.68,1.2112185834756528,10.436882727718173,1.5177766559773877e-11,0.18656638386146754,282.7203806913703,5.8723313351967805,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA05A,Trina Solar,Multi-c-Si,0,270.0,247.9,1.618355,1.643,0.985,60.0,9.13,38.5,8.46,31.9,0.0045650000000000005,-0.12705,43.6,1.5975299206055629,9.144183368006255,3.028030196289898e-10,0.2119123880518126,136.41049145592746,8.99349101518335,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA05A08,Trina Solar,Multi-c-Si,0,270.0,247.9,1.618355,1.643,0.985,60.0,9.13,38.5,8.46,31.9,0.0045650000000000005,-0.12705,43.6,1.5975299206055629,9.144183368006255,3.028030196289898e-10,0.2119123880518126,136.41049145592746,8.99349101518335,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA05A10,Trina Solar,Multi-c-Si,0,270.0,247.9,1.618355,1.643,0.985,60.0,9.13,38.5,8.46,31.9,0.0045650000000000005,-0.12705,43.6,1.5975299206055629,9.144183368006255,3.028030196289898e-10,0.2119123880518126,136.41049145592746,8.99349101518335,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA05A18,Trina Solar,Multi-c-Si,0,270.0,247.9,1.618355,1.643,0.985,60.0,9.13,38.5,8.46,31.9,0.0045650000000000005,-0.12705,43.6,1.5975299206055629,9.144183368006255,3.028030196289898e-10,0.2119123880518126,136.41049145592746,8.99349101518335,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA14,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004973999999999999,-0.159624,44.0,1.9135783444666932,8.315518379807443,6.914908133412892e-10,0.42862842810235857,139.24591671482037,7.469548634452701,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA1405,Trina Solar,Multi-c-Si,0,270.0,243.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004144999999999999,-0.14188800000000001,46.6,1.8118178662275526,8.319490372813256,1.8763789500675684e-10,0.4561807836011237,128.23638770660307,9.0364717542629,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA1408,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.25,44.3,7.6,35.5,0.00495,-0.15947999999999998,44.0,1.9070550487642592,8.271288522066914,6.529624000584514e-10,0.42884423295896856,166.19122180336564,6.997860101558712,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA1410,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004973999999999999,-0.159624,44.0,1.9135783444666932,8.315518379807443,6.914908133412892e-10,0.42862842810235857,139.24591671482037,7.469548634452701,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA1418,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004973999999999999,-0.159624,44.0,1.9135783444666932,8.315518379807443,6.914908133412892e-10,0.42862842810235857,139.24591671482037,7.469548634452701,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA1420,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004973999999999999,-0.159624,44.0,1.9135783444666932,8.315518379807443,6.914908133412892e-10,0.42862842810235857,139.24591671482037,7.469548634452701,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PA1428,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.25,44.3,7.6,35.5,0.00495,-0.15947999999999998,44.0,1.9070550487642592,8.271288522066914,6.529624000584514e-10,0.42884423295896856,166.19122180336564,6.997860101558712,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PD05,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD05001,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD05002,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0500C,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0500D,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0500M,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0500S,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0500U,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0505,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD05051,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD05052,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0505C,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0505D,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0505M,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0505S,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0505U,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0508,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD05081,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD05082,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0508C,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0508D,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0508M,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0508S,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0508U,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0510,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0510C,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0510D,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0515,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0515C,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0515D,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0518,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0518C,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD0518D,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PD1408,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.25,44.3,7.6,35.5,0.00495,-0.15947999999999998,44.0,1.9070550487642592,8.271288522066914,6.529624000584514e-10,0.42884423295896856,166.19122180336564,6.997860101558712,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PD1410,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004973999999999999,-0.159624,44.0,1.9135783444666932,8.315518379807443,6.914908133412892e-10,0.42862842810235857,139.24591671482037,7.469548634452701,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PD1418,Trina Solar,Multi-c-Si,0,270.0,244.2,1.92075,1.95,0.985,72.0,8.29,44.34,7.6,35.52,0.004973999999999999,-0.159624,44.0,1.9135783444666932,8.315518379807443,6.914908133412892e-10,0.42862842810235857,139.24591671482037,7.469548634452701,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PE05A,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PE05A08,Trina Solar,Multi-c-Si,0,270.0,242.7,1.6367999999999998,1.65,0.992,60.0,9.18,38.4,8.73,30.9,0.00474606,-0.1334016,46.3,1.611594390984569,9.180002778073863,4.118705461359343e-10,0.30241431288203013,999998.8004219861,5.940403826258694,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-270PEG5,Trina Solar,Multi-c-Si,0,270.0,245.7,1.644736,1.658,0.992,60.0,9.26,37.6,8.69,31.1,0.0057412,-0.114304,46.5,1.5222243238122872,9.268073574711982,1.7083153680432127e-10,0.2198072448631954,252.10830158676774,12.722203391231647,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PEG507,Trina Solar,Multi-c-Si,0,270.0,245.7,1.644736,1.658,0.992,60.0,9.26,37.6,8.69,31.1,0.0057412,-0.114304,46.5,1.5222243238122872,9.268073574711982,1.7083153680432127e-10,0.2198072448631954,252.10830158676774,12.722203391231647,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PEG540,Trina Solar,Multi-c-Si,0,270.0,245.7,1.644736,1.658,0.992,60.0,9.26,37.6,8.69,31.1,0.0057412,-0.114304,46.5,1.5222243238122872,9.268073574711982,1.7083153680432127e-10,0.2198072448631954,252.10830158676774,12.722203391231647,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-270PEG547,Trina Solar,Multi-c-Si,0,270.0,245.7,1.644736,1.658,0.992,60.0,9.26,37.6,8.69,31.1,0.0057412,-0.114304,46.5,1.5222243238122872,9.268073574711982,1.7083153680432127e-10,0.2198072448631954,252.10830158676774,12.722203391231647,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A(II),Trina Solar,Mono-c-Si,0,275.0,251.1,1.629856,1.643,0.992,60.0,9.3,38.9,8.77,31.4,0.005022,-0.115144,45.8,1.5402274430640566,9.30581089781221,9.926261203638589e-11,0.3327260116738373,532.5084606701648,10.860330190199747,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A001(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A002(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A00M(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A00S(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A00U(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A05(II),Trina Solar,Mono-c-Si,0,275.0,251.1,1.629856,1.643,0.992,60.0,9.3,38.9,8.77,31.4,0.005022,-0.115144,45.8,1.5402274430640566,9.30581089781221,9.926261203638589e-11,0.3327260116738373,532.5084606701648,10.860330190199747,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A051(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A052(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A05M(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A05S(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A05U(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A08(II),Trina Solar,Mono-c-Si,0,275.0,251.1,1.629856,1.643,0.992,60.0,9.3,38.9,8.77,31.4,0.005022,-0.115144,45.8,1.5402274430640566,9.30581089781221,9.926261203638589e-11,0.3327260116738373,532.5084606701648,10.860330190199747,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A081(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A082(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A08M(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A08S(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A08U(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A10(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A15(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD05A18(II),Trina Solar,Mono-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD061M(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD061M08(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD061M10(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD061M18(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD061MT0(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD061MT8(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD09M4C,Trina Solar,Mono-c-Si,0,275.0,255.4,1.62,,,56.0,9.02,38.9,8.57,32.1,0.00316602,-0.09931170000000002,45.52,1.4042025619745881,9.023721517694645,8.348414982533923e-12,0.2854507339301663,691.8590259244484,5.811352815070571,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD09M4C08,Trina Solar,Mono-c-Si,0,275.0,255.4,1.62,,,56.0,9.02,38.9,8.57,32.1,0.00316602,-0.09931170000000002,45.52,1.4042025619745881,9.023721517694645,8.348414982533923e-12,0.2854507339301663,691.8590259244484,5.811352815070571,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DD09M4C18,Trina Solar,Mono-c-Si,0,275.0,255.4,1.62,,,56.0,9.02,38.9,8.57,32.1,0.00316602,-0.09931170000000002,45.52,1.4042025619745881,9.023721517694645,8.348414982533923e-12,0.2854507339301663,691.8590259244484,5.811352815070571,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE05A(II),Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE05A08(II),Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.26,38.7,8.76,31.4,0.0047874200000000006,-0.1344438,46.3,1.6276286376156723,9.26055430179573,4.3659052295365613e-10,0.2887301522783852,4823.4547384161415,6.368046088238682,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE061M(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE061M08(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE061M10(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE061M18(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE061MT0(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DE061MT8(II),Trina Solar,Mono-c-Si,0,275.0,254.3,1.62,,,48.0,10.5,33.2,9.98,27.6,0.00273,-0.08798,45.68,1.2167679630690547,10.503568938132737,1.475291964210624e-11,0.18276634963959515,537.7080325150367,5.552538629392682,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DEG5(II),Trina Solar,Mono-c-Si,0,275.0,249.7,1.644736,1.658,0.992,60.0,9.26,38.7,8.76,31.4,0.00505596,-0.1166418,46.2,1.559414431851126,9.262330818469302,1.5393239836659516e-10,0.3048728453679436,1211.2154959072043,12.797588221095276,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DEG507(II),Trina Solar,Mono-c-Si,0,275.0,249.7,1.644736,1.658,0.992,60.0,9.26,38.7,8.76,31.4,0.00505596,-0.1166418,46.2,1.559414431851126,9.262330818469302,1.5393239836659516e-10,0.3048728453679436,1211.2154959072043,12.797588221095276,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DEG540(II),Trina Solar,Mono-c-Si,0,275.0,249.7,1.644736,1.658,0.992,60.0,9.26,38.7,8.76,31.4,0.00505596,-0.1166418,46.2,1.559414431851126,9.262330818469302,1.5393239836659516e-10,0.3048728453679436,1211.2154959072043,12.797588221095276,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275DEG547(II),Trina Solar,Mono-c-Si,0,275.0,249.7,1.644736,1.658,0.992,60.0,9.26,38.7,8.76,31.4,0.00505596,-0.1166418,46.2,1.559414431851126,9.262330818469302,1.5393239836659516e-10,0.3048728453679436,1211.2154959072043,12.797588221095276,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA14,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA1405,Trina Solar,Multi-c-Si,0,275.0,247.8,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.004195,-0.14208,46.6,1.8241303938055522,8.418587329830316,2.1616514408618695e-10,0.40790286079877086,119.71405393718283,10.190332627279698,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA1408,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.27,44.3,7.73,35.6,0.004961999999999999,-0.15947999999999998,44.0,1.8950546689169683,8.278979591475734,5.747602565462194e-10,0.41341215669305875,380.74334055535235,5.830569339581864,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA1410,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA1418,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA1420,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PA1428,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.27,44.3,7.73,35.6,0.004961999999999999,-0.15947999999999998,44.0,1.8950546689169683,8.278979591475734,5.747602565462194e-10,0.41341215669305875,380.74334055535235,5.830569339581864,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PD05,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD05001,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD05002,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0500C,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0500D,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0500M,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0500S,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0500U,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0505,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD05051,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD05052,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0505C,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0505D,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0505M,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0505S,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0505U,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0508,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD05081,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD05082,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0508C,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0508D,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0508M,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0508S,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0508U,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0510,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0510C,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0510D,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0515,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0515C,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0515D,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0518,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0518C,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD0518D,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PD14,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PD1408,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.27,44.3,7.73,35.6,0.004961999999999999,-0.15947999999999998,44.0,1.8950546689169683,8.278979591475734,5.747602565462194e-10,0.41341215669305875,380.74334055535235,5.830569339581864,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PD1410,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PD1418,Trina Solar,Multi-c-Si,0,275.0,248.9,1.92075,1.95,0.985,72.0,8.39,44.4,7.68,35.85,0.005034,-0.15984,44.0,1.92712568436187,8.414692941856016,7.961560855325214e-10,0.38012411531939033,129.1560066582622,8.608378703468095,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PE05A,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PE05A08,Trina Solar,Multi-c-Si,0,275.0,247.3,1.6367999999999998,1.65,0.992,60.0,9.25,38.5,8.84,31.1,0.00478225,-0.133749,46.3,1.6225741200827326,9.250002453902864,4.584774721265712e-10,0.2651112040321797,999998.1804861465,6.795856966404382,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-275PEG5,Trina Solar,Multi-c-Si,0,275.0,250.3,1.644736,1.658,0.992,60.0,9.34,37.7,8.78,31.3,0.0057908,-0.11460800000000002,46.5,1.528072671947071,9.346746481892579,1.7768316967673263e-10,0.20314168499666105,281.23449985849453,12.996976449883956,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PEG507,Trina Solar,Multi-c-Si,0,275.0,250.3,1.644736,1.658,0.992,60.0,9.34,37.7,8.78,31.3,0.0057908,-0.11460800000000002,46.5,1.528072671947071,9.346746481892579,1.7768316967673263e-10,0.20314168499666105,281.23449985849453,12.996976449883956,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PEG540,Trina Solar,Multi-c-Si,0,275.0,250.3,1.644736,1.658,0.992,60.0,9.34,37.7,8.78,31.3,0.0057908,-0.11460800000000002,46.5,1.528072671947071,9.346746481892579,1.7768316967673263e-10,0.20314168499666105,281.23449985849453,12.996976449883956,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-275PEG547,Trina Solar,Multi-c-Si,0,275.0,250.3,1.644736,1.658,0.992,60.0,9.34,37.7,8.78,31.3,0.0057908,-0.11460800000000002,46.5,1.528072671947071,9.346746481892579,1.7768316967673263e-10,0.20314168499666105,281.23449985849453,12.996976449883956,-0.408,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A(II),Trina Solar,Mono-c-Si,0,280.0,255.8,1.629856,1.643,0.992,60.0,9.4,39.1,8.88,31.6,0.005076,-0.11573599999999999,45.8,1.5478183087329043,9.404223195786644,9.998969962624816e-11,0.32580259597504174,725.1723380217435,10.823404589206012,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A001(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A002(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A00M(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A00S(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A00U(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A05(II),Trina Solar,Mono-c-Si,0,280.0,255.8,1.629856,1.643,0.992,60.0,9.4,39.1,8.88,31.6,0.005076,-0.11573599999999999,45.8,1.5478183087329043,9.404223195786644,9.998969962624816e-11,0.32580259597504174,725.1723380217435,10.823404589206012,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A051(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A052(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A05M(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A05S(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A05U(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A08(II),Trina Solar,Mono-c-Si,0,280.0,255.8,1.629856,1.643,0.992,60.0,9.4,39.1,8.88,31.6,0.005076,-0.11573599999999999,45.8,1.5478183087329043,9.404223195786644,9.998969962624816e-11,0.32580259597504174,725.1723380217435,10.823404589206012,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A081(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A082(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A08M(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A08S(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A08U(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A10(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A15(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD05A18(II),Trina Solar,Mono-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD061M(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD061M08(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD061M10(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD061M18(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD061MT0(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD061MT8(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD09M4C,Trina Solar,Mono-c-Si,0,280.0,260.2,1.62,,,56.0,9.12,39.1,8.67,32.3,0.0032011199999999996,-0.09982230000000002,45.52,1.4117978013624177,9.123339205560356,8.508248348880083e-12,0.2791646497164814,762.4512491071358,5.877471665108751,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD09M4C08,Trina Solar,Mono-c-Si,0,280.0,260.2,1.62,,,56.0,9.12,39.1,8.67,32.3,0.0032011199999999996,-0.09982230000000002,45.52,1.4117978013624177,9.123339205560356,8.508248348880083e-12,0.2791646497164814,762.4512491071358,5.877471665108751,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DD09M4C18,Trina Solar,Mono-c-Si,0,280.0,260.2,1.62,,,56.0,9.12,39.1,8.67,32.3,0.0032011199999999996,-0.09982230000000002,45.52,1.4117978013624177,9.123339205560356,8.508248348880083e-12,0.2791646497164814,762.4512491071358,5.877471665108751,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE05A(II),Trina Solar,Multi-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE05A08(II),Trina Solar,Multi-c-Si,0,280.0,252.0,1.6367999999999998,1.65,0.992,60.0,9.35,39.0,8.84,31.7,0.00483395,-0.135486,46.3,1.6424394036047845,9.351149169984918,4.5464799488633477e-10,0.28057363631267335,2282.8341148662366,6.636176652436387,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE061M(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE061M08(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE061M10(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE061M18(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE061MT0(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DE061MT8(II),Trina Solar,Mono-c-Si,0,280.0,259.0,1.62,,,48.0,10.6,33.3,10.09,27.8,0.0027559999999999998,-0.08824499999999999,45.68,1.222135751293626,10.602528978650936,1.5491187817332966e-11,0.1683840053989535,705.7671863972278,5.883706387094233,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DEG5(II),Trina Solar,Mono-c-Si,0,280.0,254.4,1.644736,1.658,0.992,60.0,9.35,39.0,8.84,31.7,0.0051051000000000004,-0.117546,46.2,1.5734987412384316,9.352926804680184,1.6025600720802827e-10,0.29676485461546603,948.0482752234064,13.07922852072673,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DEG507(II),Trina Solar,Mono-c-Si,0,280.0,254.4,1.644736,1.658,0.992,60.0,9.35,39.0,8.84,31.7,0.0051051000000000004,-0.117546,46.2,1.5734987412384316,9.352926804680184,1.6025600720802827e-10,0.29676485461546603,948.0482752234064,13.07922852072673,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DEG540(II),Trina Solar,Mono-c-Si,0,280.0,254.4,1.644736,1.658,0.992,60.0,9.35,39.0,8.84,31.7,0.0051051000000000004,-0.117546,46.2,1.5734987412384316,9.352926804680184,1.6025600720802827e-10,0.29676485461546603,948.0482752234064,13.07922852072673,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280DEG547(II),Trina Solar,Mono-c-Si,0,280.0,254.4,1.644736,1.658,0.992,60.0,9.35,39.0,8.84,31.7,0.0051051000000000004,-0.117546,46.2,1.5734987412384316,9.352926804680184,1.6025600720802827e-10,0.29676485461546603,948.0482752234064,13.07922852072673,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA14,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA1405,Trina Solar,Multi-c-Si,0,280.0,252.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.004225,-0.142208,46.6,1.8237608955228282,8.473108186304902,2.1333617902752108e-10,0.38646149055997114,141.31787423950013,9.990821061309228,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA1408,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.33,44.4,7.78,36.0,0.004998,-0.15984,44.0,1.9102664871579724,8.339095604986912,6.604877580010704e-10,0.3625183345390989,332.0041467561926,6.972945397718513,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA1410,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA1418,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA1420,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PA1428,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.33,44.4,7.78,36.0,0.004998,-0.15984,44.0,1.9102664871579724,8.339095604986912,6.604877580010704e-10,0.3625183345390989,332.0041467561926,6.972945397718513,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD0505,Trina Solar,Multi-c-Si,0,280.0,257.2,1.62,,,60.0,9.4,38.2,8.92,31.4,0.0040514,-0.11062720000000002,45.8,1.46989242972651,9.402384796986121,4.841194220232813e-11,0.2620153722403139,1032.7691302043754,6.98375745455514,-0.3869,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD0508,Trina Solar,Multi-c-Si,0,280.0,257.5,1.62,,,60.0,9.4,38.2,8.92,31.4,0.0034498000000000003,-0.1140652,44.8,1.4862728657150843,9.401985551569053,6.450453742831937e-11,0.25807119016461055,1221.7610207959974,6.245082348391732,-0.4015,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD0518,Trina Solar,Multi-c-Si,0,280.0,257.5,1.62,,,60.0,9.4,38.2,8.92,31.4,0.0034498000000000003,-0.1140652,44.8,1.4862728657150843,9.401985551569053,6.450453742831937e-11,0.25807119016461055,1221.7610207959974,6.245082348391732,-0.4015,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD14,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD1408,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.33,44.4,7.78,36.0,0.004998,-0.15984,44.0,1.9102664871579724,8.339095604986912,6.604877580010704e-10,0.3625183345390989,332.0041467561926,6.972945397718513,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD1410,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-280PD1418,Trina Solar,Multi-c-Si,0,280.0,253.5,1.92075,1.95,0.985,72.0,8.45,44.44,7.78,36.01,0.005069999999999999,-0.159984,44.0,1.926638412758052,8.46960914224329,7.85971640017783e-10,0.35903079435532015,154.71409045722538,8.414917482591992,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD05A(II),Trina Solar,Mono-c-Si,0,285.0,260.5,1.629856,1.643,0.992,60.0,9.45,39.3,8.99,31.7,0.005103,-0.11632799999999999,45.8,1.552726614471107,9.45000305604154,9.622766001741337e-11,0.323327660629332,999999.7959561697,10.415983805425297,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A001(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A002(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A00M(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A00S(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A00U(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A05(II),Trina Solar,Mono-c-Si,0,285.0,260.5,1.629856,1.643,0.992,60.0,9.45,39.3,8.99,31.7,0.005103,-0.11632799999999999,45.8,1.552726614471107,9.45000305604154,9.622766001741337e-11,0.323327660629332,999999.7959561697,10.415983805425297,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A051(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A052(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A05M(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A05S(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A05U(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A08(II),Trina Solar,Mono-c-Si,0,285.0,260.5,1.629856,1.643,0.992,60.0,9.45,39.3,8.99,31.7,0.005103,-0.11632799999999999,45.8,1.552726614471107,9.45000305604154,9.622766001741337e-11,0.323327660629332,999999.7959561697,10.415983805425297,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A081(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A082(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A08M(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A08S(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A08U(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A10(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A15(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD05A18(II),Trina Solar,Mono-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DD061M(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD061M08(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD061M10(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD061M18(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD061MT0(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD061MT8(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD09M4C,Trina Solar,Mono-c-Si,0,285.0,264.9,1.62,,,56.0,9.22,39.3,8.77,32.5,0.00323622,-0.1003329,45.52,1.4193962611905948,9.222969428868073,8.66984269161051e-12,0.27302108550653287,847.7234364472974,5.94341992620683,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD09M4C08,Trina Solar,Mono-c-Si,0,285.0,264.9,1.62,,,56.0,9.22,39.3,8.77,32.5,0.00323622,-0.1003329,45.52,1.4193962611905948,9.222969428868073,8.66984269161051e-12,0.27302108550653287,847.7234364472974,5.94341992620683,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DD09M4C18,Trina Solar,Mono-c-Si,0,285.0,264.9,1.62,,,56.0,9.22,39.3,8.77,32.5,0.00323622,-0.1003329,45.52,1.4193962611905948,9.222969428868073,8.66984269161051e-12,0.27302108550653287,847.7234364472974,5.94341992620683,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DE05A(II),Trina Solar,Multi-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DE05A08(II),Trina Solar,Multi-c-Si,0,285.0,256.6,1.6367999999999998,1.65,0.992,60.0,9.45,39.3,8.97,31.8,0.00488565,-0.1365282,46.3,1.6496966810649634,9.478070826072903,4.272787687026698e-10,0.29795901289237886,999999.980359786,5.983018183519936,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DE061M(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DE061M08(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DE061M10(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DE061M18(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DE061MT0(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DE061MT8(II),Trina Solar,Mono-c-Si,0,285.0,263.8,1.62,,,48.0,10.7,33.6,10.19,28.0,0.0027819999999999998,-0.08904000000000001,45.68,1.2317666753080212,10.702192568510085,1.5178389367092765e-11,0.17402027790110514,849.2400627540992,5.626038183176179,-0.3579,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285DEG5(II),Trina Solar,Mono-c-Si,0,285.0,259.0,1.644736,1.658,0.992,60.0,9.45,39.3,8.97,31.8,0.005159700000000001,-0.11845019999999999,46.2,1.579247386614527,9.45886780503884,1.473334143051064e-10,0.3145140877993822,999999.9803195627,12.197045561170816,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DEG507(II),Trina Solar,Mono-c-Si,0,285.0,259.0,1.644736,1.658,0.992,60.0,9.45,39.3,8.97,31.8,0.005159700000000001,-0.11845019999999999,46.2,1.579247386614527,9.45886780503884,1.473334143051064e-10,0.3145140877993822,999999.9803195627,12.197045561170816,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DEG540(II),Trina Solar,Mono-c-Si,0,285.0,259.0,1.644736,1.658,0.992,60.0,9.45,39.3,8.97,31.8,0.005159700000000001,-0.11845019999999999,46.2,1.579247386614527,9.45886780503884,1.473334143051064e-10,0.3145140877993822,999999.9803195627,12.197045561170816,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285DEG547(II),Trina Solar,Mono-c-Si,0,285.0,259.0,1.644736,1.658,0.992,60.0,9.45,39.3,8.97,31.8,0.005159700000000001,-0.11845019999999999,46.2,1.579247386614527,9.45886780503884,1.473334143051064e-10,0.3145140877993822,999999.9803195627,12.197045561170816,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285PA14,Trina Solar,Multi-c-Si,0,285.0,259.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0029035800000000002,-0.149164,43.8,1.8561739738341438,8.506872136552337,3.197734100142422e-10,0.34903125471149066,175.63131762229787,8.57885130677881,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA1405,Trina Solar,Multi-c-Si,0,285.0,257.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0042450000000000005,-0.1424,46.6,1.8263487032142678,8.50779320040174,2.1599605819944823e-10,0.3569857355210468,170.33523945956037,10.040890165895389,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA1408,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.36,44.8,7.86,36.3,0.005016,-0.16127999999999998,44.0,1.919740881716212,8.364350296462595,6.0846210433752e-10,0.3689759373076706,709.0644471014648,6.210270939788276,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA1410,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0050940000000000004,-0.1602,44.0,1.9293914377024717,8.504724957309675,7.958938405300334e-10,0.3297126105355689,190.10313570549846,8.467654426311388,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA1418,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0050940000000000004,-0.1602,44.0,1.9293914377024717,8.504724957309675,7.958938405300334e-10,0.3297126105355689,190.10313570549846,8.467654426311388,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA1420,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0050940000000000004,-0.1602,44.0,1.9293914377024717,8.504724957309675,7.958938405300334e-10,0.3297126105355689,190.10313570549846,8.467654426311388,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA1428,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.36,44.8,7.86,36.3,0.005016,-0.16127999999999998,44.0,1.919740881716212,8.364350296462595,6.0846210433752e-10,0.3689759373076706,709.0644471014648,6.210270939788276,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA14A,Trina Solar,Multi-c-Si,0,285.0,261.3,1.92075,1.95,0.985,72.0,8.67,44.9,8.05,35.4,0.004335,-0.14817000000000002,43.3,1.8085742312998352,8.690921943074382,1.401990719666116e-10,0.5246189365186732,217.40076960459524,2.835182716509114,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PA14A08,Trina Solar,Multi-c-Si,0,285.0,261.3,1.92075,1.95,0.985,72.0,8.67,44.9,8.05,35.4,0.004335,-0.14817000000000002,43.3,1.8085742312998352,8.690921943074382,1.401990719666116e-10,0.5246189365186732,217.40076960459524,2.835182716509114,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PD0518,Trina Solar,Multi-c-Si,0,285.0,262.2,1.62,,,60.0,9.43,38.8,9.02,31.6,0.00346081,-0.11585679999999998,44.8,1.5050089232352284,9.43000259399429,5.999944611216584e-11,0.27504915970810545,999998.2758633061,5.590020618367532,-0.4015,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-285PD14,Trina Solar,Multi-c-Si,0,285.0,259.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0029035800000000002,-0.149164,43.8,1.8561739738341438,8.506872136552337,3.197734100142422e-10,0.34903125471149066,175.63131762229787,8.57885130677881,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PD1408,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.36,44.8,7.86,36.3,0.005016,-0.16127999999999998,44.0,1.919740881716212,8.364350296462595,6.0846210433752e-10,0.3689759373076706,709.0644471014648,6.210270939788276,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PD1410,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0050940000000000004,-0.1602,44.0,1.9293914377024717,8.504724957309675,7.958938405300334e-10,0.3297126105355689,190.10313570549846,8.467654426311388,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PD1418,Trina Solar,Multi-c-Si,0,285.0,258.1,1.92075,1.95,0.985,72.0,8.49,44.5,7.86,36.25,0.0050940000000000004,-0.1602,44.0,1.9293914377024717,8.504724957309675,7.958938405300334e-10,0.3297126105355689,190.10313570549846,8.467654426311388,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-285PE06H,Trina Solar,Multi-c-Si,0,285.0,264.0,1.66,,,40.0,9.53,38.8,9.05,31.5,0.0047554699999999995,-0.1137228,45.3,1.447705437464096,9.532230491270175,2.179536781842703e-11,0.321219937848822,1372.4415527654542,-1.0984021333517293,-0.3582,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290DD05A(II),Trina Solar,Mono-c-Si,0,290.0,265.1,1.64,,,60.0,9.5,39.5,9.01,32.2,0.00513,-0.11692,45.8,1.5678937730124896,9.5011343978581,1.0860144899781272e-10,0.28983525468468435,2427.2226004054155,11.456434350643491,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290DD05A001(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A002(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A00M(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A00S(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A00U(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A05(II),Trina Solar,Mono-c-Si,0,290.0,265.2,1.629856,1.643,0.992,60.0,9.5,39.5,9.1,31.9,0.00513,-0.11692,45.8,1.5663260080024823,9.50000275499655,1.0606579296925527e-10,0.289935680995275,999964.3621599309,11.238795706610212,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A051(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A052(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A05M(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A05S(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A05U(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A08(II),Trina Solar,Mono-c-Si,0,290.0,265.2,1.629856,1.643,0.992,60.0,9.5,39.5,9.1,31.9,0.00513,-0.11692,45.8,1.5663260080024823,9.50000275499655,1.0606579296925527e-10,0.289935680995275,999964.3621599309,11.238795706610212,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A081(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A082(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A08M(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A08S(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A08U(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A10(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A15(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DD05A18(II),Trina Solar,Mono-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DE05A(II),Trina Solar,Multi-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DE05A08(II),Trina Solar,Multi-c-Si,0,290.0,261.3,1.6367999999999998,1.65,0.992,60.0,9.5,39.5,9.01,32.2,0.0049115,-0.137223,46.3,1.664668301926373,9.513471035484104,4.711963575554845e-10,0.26720707349697115,999999.980695131,6.790481546964681,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290DEG5(II),Trina Solar,Mono-c-Si,0,290.0,263.7,1.644736,1.658,0.992,60.0,9.5,39.5,9.01,32.2,0.005187000000000001,-0.119053,46.2,1.5936983339617494,9.500494925977149,1.6344626980091641e-10,0.2838104268787611,5447.633173662452,13.102228654321554,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290DEG507(II),Trina Solar,Mono-c-Si,0,290.0,263.7,1.644736,1.658,0.992,60.0,9.5,39.5,9.01,32.2,0.005187000000000001,-0.119053,46.2,1.5936983339617494,9.500494925977149,1.6344626980091641e-10,0.2838104268787611,5447.633173662452,13.102228654321554,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290DEG540(II),Trina Solar,Mono-c-Si,0,290.0,263.7,1.644736,1.658,0.992,60.0,9.5,39.5,9.01,32.2,0.005187000000000001,-0.119053,46.2,1.5936983339617494,9.500494925977149,1.6344626980091641e-10,0.2838104268787611,5447.633173662452,13.102228654321554,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290DEG547(II),Trina Solar,Mono-c-Si,0,290.0,263.7,1.644736,1.658,0.992,60.0,9.5,39.5,9.01,32.2,0.005187000000000001,-0.119053,46.2,1.5936983339617494,9.500494925977149,1.6344626980091641e-10,0.2838104268787611,5447.633173662452,13.102228654321554,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290DEG5C07(II),Trina Solar,Mono-c-Si,1,290.0,269.4,1.645,,,60.0,9.48,39.7,8.87,32.7,0.0036592800000000004,-0.1089368,43.4,1.5242387089735971,9.49329230610566,4.530279396021951e-11,0.2641429259344279,188.3852924797415,12.389840858329253,-0.3837,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA14,Trina Solar,Multi-c-Si,0,290.0,263.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.0028967400000000005,-0.1505048,43.8,1.8514424987251714,8.475421071793217,2.466302591864967e-10,0.3809522211718565,595.208130102619,6.290672868920627,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA1408,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA1410,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA1418,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA1420,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA1428,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA14A,Trina Solar,Multi-c-Si,0,290.0,266.0,1.92075,1.95,0.985,72.0,8.7,45.0,8.13,35.7,0.00435,-0.14850000000000002,43.3,1.8130942534897063,8.713364173733957,1.4261488071006966e-10,0.49120354675423095,319.7707076977759,2.928736915156654,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PA14A08,Trina Solar,Multi-c-Si,0,290.0,266.0,1.92075,1.95,0.985,72.0,8.7,45.0,8.13,35.7,0.00435,-0.14850000000000002,43.3,1.8130942534897063,8.713364173733957,1.4261488071006966e-10,0.49120354675423095,319.7707076977759,2.928736915156654,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PD14,Trina Solar,Multi-c-Si,0,290.0,266.0,1.92075,1.95,0.985,72.0,8.63,44.7,8.17,35.5,0.004315000000000001,-0.14751000000000003,43.3,1.790769891151782,8.633975196583183,1.2463506183196472e-10,0.48522763638165683,999999.9365697764,1.8370281862874147,-0.43,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-290PD1408,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PD1410,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PD1418,Trina Solar,Multi-c-Si,0,290.0,262.8,1.92075,1.95,0.985,72.0,8.47,44.9,7.97,36.4,0.005082000000000001,-0.16164,44.0,1.9237580077499368,8.473801764429192,6.150353730527496e-10,0.36226981410614695,807.1061035799125,6.187597339499515,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-290PE06H,Trina Solar,Multi-c-Si,0,290.0,268.7,1.66,,,40.0,9.6,39.2,9.12,31.8,0.0047904,-0.11489520000000002,45.3,1.461769787076273,9.601825235404071,2.162342268343207e-11,0.32529663928960895,1710.9289123165333,-1.2221591911740395,-0.3582,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DD05A(II),Trina Solar,Mono-c-Si,0,295.0,269.9,1.629856,1.643,0.992,60.0,9.55,39.6,9.23,32.0,0.005157000000000001,-0.117216,45.8,1.577556043742744,9.550207447591708,1.1971233475418772e-10,0.2414943754410439,11117.389380377042,12.283435963020374,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A001(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A002(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A00M(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A00S(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A00U(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A05(II),Trina Solar,Mono-c-Si,0,295.0,269.9,1.629856,1.643,0.992,60.0,9.55,39.6,9.23,32.0,0.005157000000000001,-0.117216,45.8,1.577556043742744,9.550207447591708,1.1971233475418772e-10,0.2414943754410439,11117.389380377042,12.283435963020374,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A051(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A05M(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A05S(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A05U(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A08(II),Trina Solar,Mono-c-Si,0,295.0,269.9,1.629856,1.643,0.992,60.0,9.55,39.6,9.23,32.0,0.005157000000000001,-0.117216,45.8,1.577556043742744,9.550207447591708,1.1971233475418772e-10,0.2414943754410439,11117.389380377042,12.283435963020374,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A08M(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A08S(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A08U(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A10(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A15(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05A18(II),Trina Solar,Mono-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DD05H(II),Trina Solar,Mono-c-Si,0,295.0,275.6,1.64,,,40.0,9.65,39.5,9.19,32.08645054031587,0.0029336,-0.10902000000000002,43.5,1.433064094537999,9.650702493102118,1.0317391627321512e-11,0.32982597945012637,4530.750655086886,-0.9630560078610493,-0.3547,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DD05H05(II),Trina Solar,Mono-c-Si,0,295.0,273.9,1.64,,,40.0,9.65,39.5,9.19,32.1,0.0041109,-0.1089015,45.2,1.4494267663805998,9.6503132464863,1.408976652003095e-11,0.32433894707418337,9991.722350789896,1.5155876640826917,-0.3532,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DD05H08(II),Trina Solar,Mono-c-Si,0,295.0,275.6,1.64,,,40.0,9.65,39.5,9.19,32.08645054031587,0.0029336,-0.10902000000000002,43.5,1.433064094537999,9.650702493102118,1.0317391627321512e-11,0.32982597945012637,4530.750655086886,-0.9630560078610493,-0.3547,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DE05A(II),Trina Solar,Multi-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DE05A08(II),Trina Solar,Multi-c-Si,0,295.0,265.9,1.6367999999999998,1.65,0.992,60.0,9.55,39.7,9.08,32.5,0.004937350000000001,-0.1379178,46.3,1.6766458464331155,9.583471089313543,4.991119370339275e-10,0.24890327882557742,999999.9809907329,7.225783114872111,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DE05H(II),Trina Solar,Mono-c-Si,0,295.0,275.6,1.64,,,40.0,9.65,39.5,9.19,32.08645,0.0029336,-0.10902000000000002,43.5,1.4330640804574648,9.650702490155433,1.031738887158558e-11,0.3298260475590167,4530.770604290988,-0.9630581535395044,-0.3547,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DE05H08(II),Trina Solar,Mono-c-Si,0,295.0,275.6,1.64,,,40.0,9.65,39.5,9.19,32.1,0.0029336,-0.10902000000000002,43.5,1.4333651916470056,9.65073580520277,1.0376843036572901e-11,0.3281288461661541,4303.331032542949,-0.9167208910075855,-0.3547,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DEG5(II),Trina Solar,Mono-c-Si,0,295.0,268.4,1.644736,1.658,0.992,60.0,9.55,39.7,9.08,32.5,0.005214300000000001,-0.1196558,46.2,1.6045452297531182,9.564276478654072,1.7188726475961752e-10,0.26578382588053295,999999.9809957026,13.49920572326044,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DEG507(II),Trina Solar,Mono-c-Si,0,295.0,273.7,1.645,1.658,0.992,60.0,9.64,39.4,9.06,32.6,0.0035475200000000006,-0.1152056,42.6,1.5583508524215433,9.648376269796428,9.938694343076315e-11,0.22847891123179487,262.94959917422557,12.161553950370463,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295DEG540(II),Trina Solar,Mono-c-Si,0,295.0,268.4,1.644736,1.658,0.992,60.0,9.55,39.7,9.08,32.5,0.005214300000000001,-0.1196558,46.2,1.6045452297531182,9.564276478654072,1.7188726475961752e-10,0.26578382588053295,999999.9809957026,13.49920572326044,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DEG547(II),Trina Solar,Mono-c-Si,0,295.0,268.4,1.644736,1.658,0.992,60.0,9.55,39.7,9.08,32.5,0.005214300000000001,-0.1196558,46.2,1.6045452297531182,9.564276478654072,1.7188726475961752e-10,0.26578382588053295,999999.9809957026,13.49920572326044,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-295DEG5C07(II),Trina Solar,Mono-c-Si,1,295.0,274.1,1.645,,,60.0,9.58,39.9,8.97,32.9,0.00369788,-0.1094856,43.4,1.5322334001964593,9.592729088569104,4.606118049405974e-11,0.2582012518719281,194.3240380567334,12.442469969799614,-0.3837,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA14,Trina Solar,Multi-c-Si,0,295.0,268.5,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0029411999999999997,-0.15084,43.8,1.8575995906474598,8.606684661673542,2.566717620476356e-10,0.37315731529509266,480.0771731584387,6.507862059562687,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA1408,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA1410,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA1418,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA1420,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA1428,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA14A,Trina Solar,Multi-c-Si,0,295.0,270.7,1.92075,1.95,0.985,72.0,8.72,45.2,8.15,36.2,0.004360000000000001,-0.14916000000000001,43.3,1.8308543457750164,8.732695076970487,1.6287863272242067e-10,0.44285689401198386,304.18976460116994,4.020281887420167,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PA14A08,Trina Solar,Multi-c-Si,0,295.0,270.7,1.92075,1.95,0.985,72.0,8.72,45.2,8.15,36.2,0.004360000000000001,-0.14916000000000001,43.3,1.8308543457750164,8.732695076970487,1.6287863272242067e-10,0.44285689401198386,304.18976460116994,4.020281887420167,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PD14,Trina Solar,Multi-c-Si,0,295.0,270.7,1.92075,1.95,0.985,72.0,8.72,45.1,8.25,35.8,0.004360000000000001,-0.14883000000000002,43.3,1.8064856903149982,8.720131155881782,1.253231080052426e-10,0.4872652660145138,32396.5014588113,1.801008098499583,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PD1408,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PD1410,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PD1418,Trina Solar,Multi-c-Si,0,295.0,266.9,1.92075,1.95,0.985,72.0,8.6,45.0,8.08,36.5,0.0031647999999999997,-0.14350500000000002,46.2,1.8060984602609507,8.607976235965367,1.2844488531329602e-10,0.38646319438990817,416.6857199372174,5.892528008870687,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PE06H,Trina Solar,Multi-c-Si,0,295.0,273.5,1.66,,,40.0,9.67,39.5,9.19,32.1,0.00482533,-0.11577450000000002,45.3,1.4740459464698235,9.671583935592263,2.222272373723914e-11,0.31827288813815946,1943.0708958069483,-1.0622493899767844,-0.3582,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-295PE06HT0,Trina Solar,Multi-c-Si,0,295.0,271.5,1.66,,,40.0,9.67,39.5,9.19,32.1,0.004274140000000001,-0.11853949999999999,46.2,1.4933555521297572,9.671022928484613,3.1446192533782684e-11,0.3137609190649028,2966.0614117944233,-0.5606098238674179,-0.3744,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300DD05A(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A001(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A002(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A00M(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A00S(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A00U(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A05(II),Trina Solar,Mono-c-Si,0,300.0,273.7,1.62,1.65,0.992,60.0,9.77,39.8,9.19,32.6,0.00482638,-0.12620579999999998,45.3,1.6315708431628655,9.776815953131676,2.461985368123779e-10,0.25438031377991727,364.62925236622374,10.915596412502193,-0.4351,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300DD05A051(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A052(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A05M(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A05S(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A05U(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A08(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A081(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A082(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A08M(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A08S(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A08U(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A10(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05A15(II),Trina Solar,Mono-c-Si,0,300.0,273.7,1.62,1.65,0.992,60.0,9.77,39.8,9.19,32.6,0.00482638,-0.12620579999999998,45.3,1.6315708431628655,9.776815953131676,2.461985368123779e-10,0.25438031377991727,364.62925236622374,10.915596412502193,-0.4351,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300DD05A18(II),Trina Solar,Mono-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05H(II),Trina Solar,Mono-c-Si,0,300.0,280.4,1.64,,,40.0,9.7,39.7,9.27,32.4,0.0029487999999999997,-0.10957200000000002,43.5,1.4443735792521835,9.700002929005484,1.1214183380476011e-11,0.3019515002776737,999999.3642158443,-0.3361556961505172,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05H05(II),Trina Solar,Mono-c-Si,0,300.0,278.7,1.64,,,40.0,9.7,39.7,9.27,32.4,0.004132199999999999,-0.1094529,45.2,1.4611711674645842,9.700002874253988,1.5381374308582498e-11,0.29630488823468315,999999.3372194727,2.196173402964049,-0.3532,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD05H08(II),Trina Solar,Mono-c-Si,0,300.0,280.4,1.64,,,40.0,9.7,39.7,9.27,32.4,0.0029487999999999997,-0.10957200000000002,43.5,1.4443735792521835,9.700002929005484,1.1214183380476011e-11,0.3019515002776737,999999.3642158443,-0.3361556961505172,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DD09M5C,Trina Solar,Mono-c-Si,0,300.0,277.6,1.92,,,64.0,8.71,44.0,8.29,36.2,0.0022646000000000003,-0.114224,45.31,1.592951032922383,8.712079264974095,8.763216673058412e-12,0.3472225060911659,1454.5082700415367,4.871636626767831,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300DD09M5CA0,Trina Solar,Mono-c-Si,0,300.0,277.6,1.92,,,64.0,8.71,44.0,8.29,36.2,0.0022646000000000003,-0.114224,45.31,1.592951032922383,8.712079264974095,8.763216673058412e-12,0.3472225060911659,1454.5082700415367,4.871636626767831,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300DE05A(II),Trina Solar,Multi-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DE05A08(II),Trina Solar,Multi-c-Si,0,300.0,270.6,1.6367999999999998,1.65,0.992,60.0,9.64,39.9,9.19,32.6,0.004983880000000001,-0.1386126,46.3,1.6887706954123707,9.640002230305578,5.28627937844009e-10,0.23120425370675488,999992.2765455669,7.6713595464996835,-0.4625,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DE05H(II),Trina Solar,Mono-c-Si,0,300.0,280.4,1.64,,,40.0,9.7,39.7,9.27,32.4,0.0029487999999999997,-0.10957200000000002,43.5,1.4443735792521835,9.700002929005484,1.1214183380476011e-11,0.3019515002776737,999999.3642158443,-0.3361556961505172,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DE05H08(II),Trina Solar,Mono-c-Si,0,300.0,280.4,1.64,,,40.0,9.7,39.7,9.27,32.4,0.0029487999999999997,-0.10957200000000002,43.5,1.4443735792521835,9.700002929005484,1.1214183380476011e-11,0.3019515002776737,999999.3642158443,-0.3361556961505172,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DEG5(II),Trina Solar,Mono-c-Si,0,300.0,277.2,1.645,1.658,0.992,60.0,9.81,39.8,9.18,32.7,0.00331578,-0.11597719999999999,43.3,1.5785993046625033,9.822296561280679,1.0812090686118303e-10,0.2539687006723398,202.61216715140336,13.205402263629132,-0.4163,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300DEG507(II),Trina Solar,Mono-c-Si,0,300.0,273.1,1.644736,1.658,0.992,60.0,9.66,40.0,9.18,32.7,0.0052743600000000005,-0.12056,46.2,1.6155775306848246,9.670872059067824,1.709186157288618e-10,0.2706268729288924,999999.9811680831,13.34590103918496,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DEG540(II),Trina Solar,Mono-c-Si,0,300.0,273.1,1.644736,1.658,0.992,60.0,9.66,40.0,9.18,32.7,0.0052743600000000005,-0.12056,46.2,1.6155775306848246,9.670872059067824,1.709186157288618e-10,0.2706268729288924,999999.9811680831,13.34590103918496,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DEG547(II),Trina Solar,Mono-c-Si,0,300.0,273.1,1.644736,1.658,0.992,60.0,9.66,40.0,9.18,32.7,0.0052743600000000005,-0.12056,46.2,1.6155775306848246,9.670872059067824,1.709186157288618e-10,0.2706268729288924,999999.9811680831,13.34590103918496,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300DEG5C07(II),Trina Solar,Mono-c-Si,1,300.0,278.9,1.645,,,60.0,9.68,40.1,9.07,33.1,0.00373648,-0.11003439999999999,43.4,1.540232791488766,9.69218155306324,4.682748651734179e-11,0.252389253162557,200.55964856437114,12.495237889391262,-0.3837,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA14,Trina Solar,Multi-c-Si,0,300.0,273.1,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0029788200000000005,-0.1511752,43.8,1.8602861612442785,8.71516800479804,2.5572325908674144e-10,0.36670996597565814,618.0420975535197,6.359740134027389,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA1408,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA1410,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA1418,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA1420,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA1428,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA14A,Trina Solar,Multi-c-Si,0,300.0,275.4,1.92075,1.95,0.985,72.0,8.75,45.4,8.2,36.6,0.004375,-0.14982,43.3,1.8432812861424566,8.759881243082472,1.736070370378445e-10,0.4088422936164791,362.03649667512457,4.52031344371445,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PA14A08,Trina Solar,Multi-c-Si,0,300.0,275.4,1.92075,1.95,0.985,72.0,8.75,45.4,8.2,36.6,0.004375,-0.14982,43.3,1.8432812861424566,8.759881243082472,1.736070370378445e-10,0.4088422936164791,362.03649667512457,4.52031344371445,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PD14,Trina Solar,Multi-c-Si,0,300.0,275.4,1.92075,1.95,0.985,72.0,8.77,45.4,8.28,36.2,0.004385,-0.14982,43.3,1.824966077112533,8.772735445494416,1.3727918676117183e-10,0.4648722288491233,1490.4084671757134,2.5128010100013327,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PD1408,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PD1410,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PD1418,Trina Solar,Multi-c-Si,0,300.0,271.5,1.92075,1.95,0.985,72.0,8.71,45.1,8.2,36.6,0.0032052800000000005,-0.1438239,46.2,1.8087453324952096,8.716413363129103,1.2796242570722915e-10,0.3798307866050079,515.8489282263382,5.744662136734202,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PE06HT0,Trina Solar,Multi-c-Si,0,300.0,276.2,1.66,,,40.0,9.77,39.8,9.29,32.3,0.00431834,-0.11943979999999998,46.2,1.5032428310829715,9.770412367682496,3.099248018710619e-11,0.3183683276404306,7542.926828453401,-0.7622888371069421,-0.3744,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-300PE14A,Trina Solar,Multi-c-Si,0,300.0,264.5,1.92075,1.95,0.985,72.0,8.77,45.4,8.28,36.2,0.00475334,-0.1756072,47.7,1.9780005920033041,8.781457848170305,9.45002905054958e-10,0.42718342765121115,999999.9201275043,2.0307629140059675,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-300PE14A08,Trina Solar,Multi-c-Si,0,300.0,264.5,1.92075,1.95,0.985,72.0,8.77,45.4,8.28,36.2,0.00475334,-0.1756072,47.7,1.9780005920033041,8.781457848170305,9.45002905054958e-10,0.42718342765121115,999999.9201275043,2.0307629140059675,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DD05A05(II),Trina Solar,Mono-c-Si,0,305.0,278.4,1.62,,,60.0,9.85,40.0,9.28,32.9,0.0048659,-0.12684,45.3,1.6422119163588866,9.855515192909216,2.5775417727482175e-10,0.23654230297878595,422.4588065759317,11.248551517133393,-0.4351,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DD05A05S(II),Trina Solar,Mono-c-Si,0,305.0,278.4,1.62,,,60.0,9.72,40.2,9.28,32.9,0.00480168,-0.1274742,45.3,1.6443392425627663,9.720002315908236,2.34555652322588e-10,0.23818757020495865,999999.7268623268,10.493698615347952,-0.4351,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DD05A15(II),Trina Solar,Mono-c-Si,0,305.0,278.4,1.62,,,60.0,9.85,40.0,9.28,32.9,0.0048659,-0.12684,45.3,1.6422119163588866,9.855515192909216,2.5775417727482175e-10,0.23654230297878595,422.4588065759317,11.248551517133393,-0.4351,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DD05A18(II),Trina Solar,Mono-c-Si,0,305.0,279.3,1.64,,,60.0,9.72,40.2,9.28,32.9,0.0052488000000000005,-0.118992,45.8,1.6012601593218247,9.720002455287515,1.215074669728333e-10,0.25255610067475803,999999.7316106381,12.2572146261873,-0.41,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DD05H(II),Trina Solar,Mono-c-Si,0,305.0,285.2,1.64,,,40.0,9.75,40.0,9.36,32.6,0.002964,-0.11040000000000001,43.5,1.457210712390177,9.750003074285706,1.1688227200105973e-11,0.2894544356180819,918016.068926894,-0.042770039678830626,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DD05H05(II),Trina Solar,Mono-c-Si,0,305.0,283.5,1.64,,,40.0,9.75,40.0,9.36,32.6,0.0041535,-0.11028,45.2,1.4742015032920708,9.750003017265291,1.6037848095857495e-11,0.28361117375040357,916488.6676577112,2.500317865482384,-0.3532,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DD05H08(II),Trina Solar,Mono-c-Si,0,305.0,285.2,1.64,,,40.0,9.75,40.0,9.36,32.6,0.002964,-0.11040000000000001,43.5,1.457210712390177,9.750003074285706,1.1688227200105973e-11,0.2894544356180819,918016.068926894,-0.042770039678830626,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DD09M5C,Trina Solar,Mono-c-Si,0,305.0,282.3,1.92,,,64.0,8.8,44.2,8.38,36.4,0.002288,-0.11474320000000002,45.31,1.60057618467568,8.801744584993184,8.91724135591871e-12,0.34038745275723137,1716.9754871063537,4.930389458021669,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DD09M5CA0,Trina Solar,Mono-c-Si,0,305.0,282.3,1.92,,,64.0,8.8,44.2,8.38,36.4,0.002288,-0.11474320000000002,45.31,1.60057618467568,8.801744584993184,8.91724135591871e-12,0.34038745275723137,1716.9754871063537,4.930389458021669,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DE05H(II),Trina Solar,Mono-c-Si,0,305.0,285.2,1.64,,,40.0,9.75,40.0,9.36,32.6,0.002964,-0.11040000000000001,43.5,1.457210712390177,9.750003074285706,1.1688227200105973e-11,0.2894544356180819,918016.068926894,-0.042770039678830626,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DE05H08(II),Trina Solar,Mono-c-Si,0,305.0,285.2,1.64,,,40.0,9.75,40.0,9.36,32.6,0.002964,-0.11040000000000001,43.5,1.457210712390177,9.750003074285706,1.1688227200105973e-11,0.2894544356180819,918016.068926894,-0.042770039678830626,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305DEG5(II),Trina Solar,Mono-c-Si,0,305.0,282.0,1.645,,,60.0,9.84,40.0,9.26,32.9,0.0033259199999999996,-0.11656,43.3,1.5828964459764823,9.847961107259783,1.03022561262077e-10,0.25047011791794793,309.5833276800869,12.715222770589111,-0.4163,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DEG507(II),Trina Solar,Mono-c-Si,0,305.0,283.2,1.645,,,60.0,9.76,40.0,9.25,33.0,0.0035916800000000003,-0.11696000000000001,42.6,1.572893856608867,9.762794105041026,8.769910702874237e-11,0.24215005119729996,845.8467818090073,10.891185491798824,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DEG540(II),Trina Solar,Mono-c-Si,0,305.0,282.0,1.645,,,60.0,9.84,40.0,9.26,32.9,0.0033259199999999996,-0.11656,43.3,1.5828964459764823,9.847961107259783,1.03022561262077e-10,0.25047011791794793,309.5833276800869,12.715222770589111,-0.4163,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DEG547(II),Trina Solar,Mono-c-Si,0,305.0,283.2,1.645,,,60.0,9.76,40.0,9.25,33.0,0.0035916800000000003,-0.11696000000000001,42.6,1.572893856608867,9.762794105041026,8.769910702874237e-11,0.24215005119729996,845.8467818090073,10.891185491798824,-0.4096,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305DEG5C07(II),Trina Solar,Mono-c-Si,1,305.0,283.7,1.645,,,60.0,9.78,40.3,9.16,33.3,0.00377508,-0.11058319999999998,43.4,1.5490835647769794,9.792431902844749,4.822162361982825e-11,0.24660320461366722,193.9992136061925,12.67034765804774,-0.3837,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA14,Trina Solar,Multi-c-Si,0,305.0,277.8,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00301644,-0.1515104,43.8,1.864196545086245,8.824621479420601,2.58454663189699e-10,0.3603315424728752,687.68563381101,6.340454941364319,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA1408,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA1410,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA1418,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA1420,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA1428,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA14A,Trina Solar,Multi-c-Si,0,305.0,280.1,1.92075,1.95,0.985,72.0,8.78,45.6,8.27,36.9,0.00439,-0.15048,43.3,1.8504846865483855,8.785456805675548,1.7305563519280085e-10,0.3896582165508749,626.9601537561981,4.447733514899074,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PA14A08,Trina Solar,Multi-c-Si,0,305.0,280.1,1.92075,1.95,0.985,72.0,8.78,45.6,8.27,36.9,0.00439,-0.15048,43.3,1.8504846865483855,8.785456805675548,1.7305563519280085e-10,0.3896582165508749,626.9601537561981,4.447733514899074,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PD14,Trina Solar,Multi-c-Si,0,305.0,280.1,1.92075,1.95,0.985,72.0,8.81,45.5,8.33,36.6,0.004405000000000001,-0.15015,43.3,1.8366602816641973,8.811917613233145,1.5311836459801203e-10,0.4185135856458109,1922.7582187048934,3.3784426521435975,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PD1408,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PD1410,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PD1418,Trina Solar,Multi-c-Si,0,305.0,276.2,1.92075,1.95,0.985,72.0,8.82,45.2,8.31,36.7,0.00324576,-0.14414280000000002,46.2,1.8125529799248672,8.825853840630595,1.2932873490788287e-10,0.3733074874995554,562.4636060835406,5.725422441447857,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-305PE06HT0,Trina Solar,Multi-c-Si,0,305.0,280.9,1.66,,,40.0,9.87,40.1,9.39,32.5,0.00436254,-0.12034009999999999,46.2,1.513447938961885,9.870003178848645,3.0714240706813757e-11,0.3220490632232928,999999.86119984,-0.9176956606499004,-0.3744,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305PE14A,Trina Solar,Multi-c-Si,0,305.0,269.1,1.92075,1.95,0.985,72.0,8.81,45.5,8.33,36.6,0.0047750200000000005,-0.17599399999999998,47.7,1.9918248382084558,8.826307823169826,1.0593159073723268e-09,0.38016683834308435,999999.7182583376,2.9381318615211054,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-305PE14A08,Trina Solar,Multi-c-Si,0,305.0,269.1,1.92075,1.95,0.985,72.0,8.81,45.5,8.33,36.6,0.0047750200000000005,-0.17599399999999998,47.7,1.9918248382084558,8.826307823169826,1.0593159073723268e-09,0.38016683834308435,999999.7182583376,2.9381318615211054,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310DD05H(II),Trina Solar,Mono-c-Si,0,310.0,290.0,1.64,,,40.0,9.83,40.2,9.43,32.9,0.00298832,-0.11095200000000002,43.5,1.466631620661682,9.83000271473552,1.2264517917728958e-11,0.2761534887011935,999970.193985833,0.28141378189051547,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310DD05H05(II),Trina Solar,Mono-c-Si,0,310.0,288.2,1.64,,,40.0,9.83,40.2,9.43,32.9,0.00418758,-0.11083140000000001,45.2,1.4837569264136976,9.830002750437048,1.6828426585469265e-11,0.27033843294213833,966212.1877834809,2.832734260824648,-0.3532,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310DD05H08(II),Trina Solar,Mono-c-Si,0,310.0,290.0,1.64,,,40.0,9.83,40.2,9.43,32.9,0.00298832,-0.11095200000000002,43.5,1.466631620661682,9.83000271473552,1.2264517917728958e-11,0.2761534887011935,999970.193985833,0.28141378189051547,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310DD09M5C,Trina Solar,Mono-c-Si,0,310.0,287.1,1.92,,,64.0,8.89,44.4,8.47,36.6,0.0023114,-0.1152624,45.31,1.6082046541259682,8.891419975504672,9.072866781208435e-12,0.3336967112731923,2089.165577917137,4.989065149780764,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310DD09M5CA0,Trina Solar,Mono-c-Si,0,310.0,287.1,1.92,,,64.0,8.89,44.4,8.47,36.6,0.0023114,-0.1152624,45.31,1.6082046541259682,8.891419975504672,9.072866781208435e-12,0.3336967112731923,2089.165577917137,4.989065149780764,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310DE05H(II),Trina Solar,Mono-c-Si,0,310.0,290.0,1.64,,,40.0,9.83,40.2,9.43,32.9,0.00298832,-0.11095200000000002,43.5,1.466631620661682,9.83000271473552,1.2264517917728958e-11,0.2761534887011935,999970.193985833,0.28141378189051547,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310DE05H08(II),Trina Solar,Mono-c-Si,0,310.0,290.0,1.64,,,40.0,9.83,40.2,9.43,32.9,0.00298832,-0.11095200000000002,43.5,1.466631620661682,9.83000271473552,1.2264517917728958e-11,0.2761534887011935,999970.193985833,0.28141378189051547,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310DEG5C07(II),Trina Solar,Mono-c-Si,1,310.0,288.4,1.645,,,60.0,9.88,40.5,9.26,33.5,0.0038136800000000007,-0.111132,43.4,1.557087000661442,9.891899832202505,4.900680200570731e-11,0.24103521247663262,200.12281637267802,12.722032160952956,-0.3837,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA14,Trina Solar,Multi-c-Si,0,310.0,282.5,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.00305748,-0.1518456,43.8,1.8692182869603813,8.94497354321187,2.649083923450402e-10,0.35362592506244234,635.6467366537933,6.437435392037271,-0.4574,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA1408,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA1410,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA1418,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA1420,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA1428,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA14A,Trina Solar,Multi-c-Si,0,310.0,284.8,1.92075,1.95,0.985,72.0,8.82,45.8,8.31,37.3,0.00441,-0.15114,43.3,1.865051748302485,8.82522755870435,1.8923651492226916e-10,0.3559657106443816,600.5896885283069,5.165461650313547,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PA14A08,Trina Solar,Multi-c-Si,0,310.0,284.8,1.92075,1.95,0.985,72.0,8.82,45.8,8.31,37.3,0.00441,-0.15114,43.3,1.865051748302485,8.82522755870435,1.8923651492226916e-10,0.3559657106443816,600.5896885283069,5.165461650313547,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PD14,Trina Solar,Multi-c-Si,0,310.0,284.8,1.92075,1.95,0.985,72.0,8.85,45.5,8.38,37.0,0.004425,-0.15015,43.3,1.8465012810835246,8.85133164259597,1.7560653176056507e-10,0.36062169048899295,2396.667033492215,4.486363663147086,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PD1408,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PD1410,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PD1418,Trina Solar,Multi-c-Si,0,310.0,280.8,1.92075,1.95,0.985,72.0,8.94,45.3,8.42,36.8,0.0032899199999999996,-0.1444617,46.2,1.8174149555432535,8.946225285677688,1.3256485679712704e-10,0.3664780206333743,526.2913232854636,5.822265685741978,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PE06HT0,Trina Solar,Multi-c-Si,0,310.0,285.7,1.66,,,40.0,9.97,40.3,9.48,32.7,0.004406740000000001,-0.12094029999999999,46.2,1.522000030068443,9.970423936934106,3.155663097473491e-11,0.3166080941084371,7445.853720410628,-0.7801140395627194,-0.3744,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-310PE14A,Trina Solar,Multi-c-Si,0,310.0,273.7,1.92075,1.95,0.985,72.0,8.85,45.5,8.38,37.0,0.004796699999999999,-0.17599399999999998,47.7,2.003642430362809,8.869489951344882,1.2180306387219848e-09,0.3216322629607276,999999.9844806619,4.070618105079579,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-310PE14A08,Trina Solar,Multi-c-Si,0,310.0,273.7,1.92075,1.95,0.985,72.0,8.85,45.5,8.38,37.0,0.004796699999999999,-0.17599399999999998,47.7,2.003642430362809,8.869489951344882,1.2180306387219848e-09,0.3216322629607276,999999.9844806619,4.070618105079579,-0.5006,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-315DD05H(II),Trina Solar,Mono-c-Si,0,315.0,294.8,1.64,,,40.0,9.93,40.4,9.51,33.1,0.00301872,-0.111504,43.5,1.4735725130286692,9.930002755509209,1.2307564493557247e-11,0.27748580938093287,999997.2567359011,0.22765480706839195,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-315DD05H05(II),Trina Solar,Mono-c-Si,0,315.0,293.0,1.64,,,40.0,9.93,40.4,9.51,33.1,0.00423018,-0.11138279999999999,45.2,1.4907670527208003,9.930002698736923,1.6885157881388868e-11,0.2717667069722323,999997.3373321242,2.7764435892736077,-0.3532,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-315DD05H08(II),Trina Solar,Mono-c-Si,0,315.0,294.8,1.64,,,40.0,9.93,40.4,9.51,33.1,0.00301872,-0.111504,43.5,1.4735725130286692,9.930002755509209,1.2307564493557247e-11,0.27748580938093287,999997.2567359011,0.22765480706839195,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-315DD06H05(II),Trina Solar,Mono-c-Si,0,315.0,292.1,1.66,,,40.0,9.96,41.1,9.44,33.4,0.0035557200000000005,-0.1110933,46.3,1.4885593014410503,9.965805777475358,1.0097959004879943e-11,0.33242208893623043,570.280901203377,0.6483903390716449,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315DD09M5C,Trina Solar,Mono-c-Si,0,315.0,291.8,1.92,,,64.0,8.98,44.6,8.56,36.8,0.0023348,-0.1157816,45.31,1.615836262112331,8.981105227625228,9.230077588855083e-12,0.32714578841659764,2658.06719871948,5.047639317983596,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315DD09M5CA0,Trina Solar,Mono-c-Si,0,315.0,291.8,1.92,,,64.0,8.98,44.6,8.56,36.8,0.0023348,-0.1157816,45.31,1.615836262112331,8.981105227625228,9.230077588855083e-12,0.32714578841659764,2658.06719871948,5.047639317983596,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315DD14A(II),Trina Solar,Mono-c-Si,0,315.0,289.1,1.9403519999999999,1.956,0.992,72.0,8.96,45.8,8.47,37.2,0.0048384000000000005,-0.135568,45.7,1.7709355608533546,8.964704233411256,5.221210693459255e-11,0.38643485475215267,736.0299179396987,5.57523839352426,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315DD14A05(II),Trina Solar,Mono-c-Si,0,315.0,289.1,1.9403519999999999,1.956,0.992,72.0,8.96,45.8,8.47,37.2,0.0048384000000000005,-0.135568,45.7,1.7709355608533546,8.964704233411256,5.221210693459255e-11,0.38643485475215267,736.0299179396987,5.57523839352426,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315DD14A08(II),Trina Solar,Mono-c-Si,0,315.0,289.1,1.9403519999999999,1.956,0.992,72.0,8.96,45.8,8.47,37.2,0.0048384000000000005,-0.135568,45.7,1.7709355608533546,8.964704233411256,5.221210693459255e-11,0.38643485475215267,736.0299179396987,5.57523839352426,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315DE05H(II),Trina Solar,Mono-c-Si,0,315.0,294.8,1.64,,,40.0,9.93,40.4,9.51,33.1,0.00301872,-0.111504,43.5,1.4735725130286692,9.930002755509209,1.2307564493557247e-11,0.27748580938093287,999997.2567359011,0.22765480706839195,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-315DE05H08(II),Trina Solar,Mono-c-Si,0,315.0,294.8,1.64,,,40.0,9.93,40.4,9.51,33.1,0.00301872,-0.111504,43.5,1.4735725130286692,9.930002755509209,1.2307564493557247e-11,0.27748580938093287,999997.2567359011,0.22765480706839195,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-315DE06HT0(II),Trina Solar,Mono-c-Si,0,315.0,295.6,1.66,,,40.0,9.96,41.1,9.44,33.4,0.00426288,-0.10953150000000002,43.3,1.4925884333027832,9.96567346941098,1.0880788625977308e-11,0.3314922718145339,581.9478064078886,2.6145070709515017,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PA14A,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,8.86,46.0,8.38,37.9,0.00443,-0.15180000000000002,43.3,1.881647739942738,8.862544212347956,2.1296618035914725e-10,0.2951294230142905,1027.7630126350807,6.122243122279013,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PA14A08,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,8.86,46.0,8.38,37.9,0.00443,-0.15180000000000002,43.3,1.881647739942738,8.862544212347956,2.1296618035914725e-10,0.2951294230142905,1027.7630126350807,6.122243122279013,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD14,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD14002,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD1408,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD14082,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD1410,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD14102,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD1418,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PD14182,Trina Solar,Multi-c-Si,0,315.0,289.5,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0045,-0.15048,43.3,1.851027089332344,9.002454305051943,1.7941438793481437e-10,0.3596126360587477,1318.7092797223277,4.530427085255487,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PDG14,Trina Solar,Multi-c-Si,0,315.0,280.5,1.962176,1.978,0.992,72.0,9.0,45.6,8.51,37.1,0.002682,-0.1643424,46.7,1.9363996172577367,9.000784473792734,5.327992970169791e-10,0.3322792782837656,3812.136129026177,4.662506982090758,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PE14A,Trina Solar,Multi-c-Si,0,315.0,278.2,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0048779999999999995,-0.1763808,47.7,2.0081999835429802,9.000003265715804,1.2381064803133046e-09,0.3217130338881075,887696.7688086147,4.084005869443947,-0.5006,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PE14A08,Trina Solar,Multi-c-Si,0,315.0,278.2,1.92075,1.95,0.985,72.0,9.0,45.6,8.51,37.05,0.0048779999999999995,-0.1763808,47.7,2.0081999835429802,9.000003265715804,1.2381064803133046e-09,0.3217130338881075,887696.7688086147,4.084005869443947,-0.5006,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-315PEG14,Trina Solar,Multi-c-Si,0,315.0,280.5,1.962176,1.978,0.992,72.0,9.0,45.6,8.51,37.1,0.002682,-0.1643424,46.7,1.9363996172577367,9.000784473792734,5.327992970169791e-10,0.3322792782837656,3812.136129026177,4.662506982090758,-0.4882,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD05H(II),Trina Solar,Mono-c-Si,0,320.0,299.6,1.64,,,40.0,10.0,40.6,9.6,33.3,0.00304,-0.11205600000000002,43.5,1.483042916359538,10.000002863704019,1.2902946197186544e-11,0.26313971096048483,918898.8876066576,0.554754178280857,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320DD05H05(II),Trina Solar,Mono-c-Si,0,320.0,297.8,1.64,,,40.0,10.0,40.6,9.6,33.3,0.00426,-0.11193420000000001,45.2,1.50038691195255,10.000002805211256,1.77062061213339e-11,0.257324097993454,917333.5190475133,3.113935655925072,-0.3532,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320DD05H08(II),Trina Solar,Mono-c-Si,0,320.0,299.6,1.64,,,40.0,10.0,40.6,9.6,33.3,0.00304,-0.11205600000000002,43.5,1.483042916359538,10.000002863704019,1.2902946197186544e-11,0.26313971096048483,918898.8876066576,0.554754178280857,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320DD06H(II),Trina Solar,Mono-c-Si,0,320.0,300.3,1.664487,,,40.0,10.01,41.5,9.5,33.7,0.00428428,-0.11059750000000002,43.3,1.5056377796659257,10.014322284680645,1.0661379581782932e-11,0.33603408193907086,778.2229717817826,2.397029504426615,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD06H05(II),Trina Solar,Mono-c-Si,0,320.0,296.9,1.66,,,40.0,10.01,41.5,9.5,33.7,0.00357357,-0.1121745,46.3,1.5015751116527567,10.014452733440859,9.893913954193405e-12,0.3369649123587479,757.5164516019865,0.43477819345800245,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD06H15(II),Trina Solar,Mono-c-Si,0,320.0,296.8,1.68493,,,40.0,10.01,41.5,9.5,33.7,0.00357357,-0.1121745,46.3,1.5015751116527567,10.014452733440859,9.893913954193405e-12,0.3369649123587479,757.5164516019865,0.43477819345800245,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD06M05(II),Trina Solar,Mono-c-Si,0,320.0,297.9,1.68,,,40.0,10.2,40.3,9.58,33.4,0.004947,-0.10836669999999998,45.6,1.4905457827504882,10.212320108370003,1.8125435480013777e-11,0.23808022674784537,197.110143396461,5.759082680544571,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD06M15(II),Trina Solar,Mono-c-Si,0,320.0,297.9,1.68,,,40.0,10.2,40.3,9.58,33.4,0.004947,-0.10836669999999998,45.6,1.4905457827504882,10.212320108370003,1.8125435480013777e-11,0.23808022674784537,197.110143396461,5.759082680544571,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD06M18(II),Trina Solar,Mono-c-Si,0,320.0,298.3,1.68,,,40.0,10.2,40.3,9.58,33.4,0.004131,-0.10836669999999998,44.9,1.4875321801555759,10.212418720102331,1.7157715373487894e-11,0.23877601334621393,196.11645403039103,5.397794136705336,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD09M5C,Trina Solar,Mono-c-Si,0,320.0,296.5,1.92,,,64.0,9.07,44.8,8.65,37.0,0.0023582,-0.11630079999999998,45.31,1.6234710711088267,9.070800135368119,9.388895752293652e-12,0.3207303128518701,3635.664943914108,5.106123992476721,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD09M5CA0,Trina Solar,Mono-c-Si,0,320.0,296.5,1.92,,,64.0,9.07,44.8,8.65,37.0,0.0023582,-0.11630079999999998,45.31,1.6234710711088267,9.070800135368119,9.388895752293652e-12,0.3207303128518701,3635.664943914108,5.106123992476721,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD14A,Trina Solar,Mono-c-Si,0,320.0,293.8,1.9403519999999999,1.956,0.992,72.0,9.05,45.9,8.55,37.4,0.004887000000000001,-0.135864,45.7,1.77834640559603,9.055270098565748,5.546786208511291e-11,0.36725621891451155,630.6654289956422,6.010013816122049,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD14A(II),Trina Solar,Mono-c-Si,0,320.0,293.8,1.9403519999999999,1.956,0.992,72.0,9.05,45.9,8.55,37.4,0.004887000000000001,-0.135864,45.7,1.77834640559603,9.055270098565748,5.546786208511291e-11,0.36725621891451155,630.6654289956422,6.010013816122049,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD14A05,Trina Solar,Mono-c-Si,0,320.0,293.8,1.9403519999999999,1.956,0.992,72.0,9.05,45.9,8.55,37.4,0.004887000000000001,-0.135864,45.7,1.77834640559603,9.055270098565748,5.546786208511291e-11,0.36725621891451155,630.6654289956422,6.010013816122049,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD14A05(II),Trina Solar,Mono-c-Si,0,320.0,293.8,1.9403519999999999,1.956,0.992,72.0,9.05,45.9,8.55,37.4,0.004887000000000001,-0.135864,45.7,1.77834640559603,9.055270098565748,5.546786208511291e-11,0.36725621891451155,630.6654289956422,6.010013816122049,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD14A08,Trina Solar,Mono-c-Si,0,320.0,293.8,1.9403519999999999,1.956,0.992,72.0,9.05,45.9,8.55,37.4,0.004887000000000001,-0.135864,45.7,1.77834640559603,9.055270098565748,5.546786208511291e-11,0.36725621891451155,630.6654289956422,6.010013816122049,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DD14A08(II),Trina Solar,Mono-c-Si,0,320.0,293.8,1.9403519999999999,1.956,0.992,72.0,9.05,45.9,8.55,37.4,0.004887000000000001,-0.135864,45.7,1.77834640559603,9.055270098565748,5.546786208511291e-11,0.36725621891451155,630.6654289956422,6.010013816122049,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DE05H(II),Trina Solar,Mono-c-Si,0,320.0,299.6,1.64,,,40.0,10.0,40.6,9.6,33.3,0.00304,-0.11205600000000002,43.5,1.483042916359538,10.000002863704019,1.2902946197186544e-11,0.26313971096048483,918898.8876066576,0.554754178280857,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320DE05H08(II),Trina Solar,Mono-c-Si,0,320.0,299.6,1.64,,,40.0,10.0,40.6,9.6,33.3,0.00304,-0.11205600000000002,43.5,1.483042916359538,10.000002863704019,1.2902946197186544e-11,0.26313971096048483,918898.8876066576,0.554754178280857,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320DE06H(II),Trina Solar,Mono-c-Si,0,320.0,300.3,1.664487,,,40.0,10.01,41.5,9.5,33.7,0.00428428,-0.11059750000000002,43.3,1.5056377796659257,10.014322284680645,1.0661379581782932e-11,0.33603408193907086,778.2229717817826,2.397029504426615,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DE06H18(II),Trina Solar,Mono-c-Si,0,320.0,300.3,1.68,,,40.0,10.01,41.5,9.5,33.7,0.00428428,-0.11059750000000002,43.3,1.5056377796659257,10.014322284680645,1.0661379581782932e-11,0.33603408193907086,778.2229717817826,2.397029504426615,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DE06HT0(II),Trina Solar,Mono-c-Si,0,320.0,300.3,1.66,,,40.0,10.01,41.5,9.5,33.7,0.00428428,-0.11059750000000002,43.3,1.5056377796659257,10.014322284680645,1.0661379581782932e-11,0.33603408193907086,778.2229717817826,2.397029504426615,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DE06MT0(II),Trina Solar,Mono-c-Si,0,320.0,298.3,1.68,,,40.0,10.2,40.3,9.58,33.4,0.004131,-0.10836669999999998,44.9,1.4875321801555759,10.212418720102331,1.7157715373487894e-11,0.23877601334621393,196.11645403039103,5.397794136705336,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320DEG6H20(II),Trina Solar,Mono-c-Si,0,320.0,300.1,1.6872239999999998,,,40.0,10.01,41.5,9.5,33.7,0.00463463,-0.11138600000000003,43.4,1.5132224673409993,10.014080603419508,1.2243930450663554e-11,0.33429883296982327,820.0577782294374,2.7699032194552755,-0.3443,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD14,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD14001,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD14002,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1400C,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,12.0,43.4,9.04,35.4,0.006,-0.134974,45.8,2.016261832849375,12.165273456229928,4.022265224454544e-09,0.18689971352105073,13.57021700785215,40.31480882281481,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1400M,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1400S,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1400U,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1405,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD14051,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD14052,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1405C,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,12.0,43.4,9.04,35.4,0.006,-0.134974,45.8,2.016261832849375,12.165273456229928,4.022265224454544e-09,0.18689971352105073,13.57021700785215,40.31480882281481,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1405M,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1405S,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1405U,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1408,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD14081,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1408C,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,12.0,43.4,9.04,35.4,0.006,-0.134974,45.8,2.016261832849375,12.165273456229928,4.022265224454544e-09,0.18689971352105073,13.57021700785215,40.31480882281481,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1408M,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1408S,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1408U,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1410,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1410C,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,12.0,43.4,9.04,35.4,0.006,-0.134974,45.8,2.016261832849375,12.165273456229928,4.022265224454544e-09,0.18689971352105073,13.57021700785215,40.31480882281481,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1415,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1415C,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1418,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1418C,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,12.0,43.4,9.04,35.4,0.006,-0.134974,45.8,2.016261832849375,12.165273456229928,4.022265224454544e-09,0.18689971352105073,13.57021700785215,40.31480882281481,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PD1450,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PDG14,Trina Solar,Multi-c-Si,0,320.0,285.1,1.962176,1.978,0.992,72.0,9.07,45.9,8.6,37.2,0.00270286,-0.1654236,46.7,1.9439904242432768,9.089152471803377,5.061688539600905e-10,0.3510690307100617,999999.9847027273,4.14547787638093,-0.4882,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320PE14A,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PE14A05,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PE14A08,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PE14A10,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PE14A18,Trina Solar,Multi-c-Si,0,320.0,292.0,1.9403519999999999,1.956,0.992,72.0,9.1,45.8,8.63,37.1,0.00455,-0.14243799999999998,45.8,1.8102697096051266,9.10076555075297,9.352010629013103e-11,0.3830801663392259,4553.626256148822,5.183649096500448,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PEG14,Trina Solar,Multi-c-Si,0,320.0,285.1,1.962176,1.978,0.992,72.0,9.07,45.9,8.6,37.2,0.00270286,-0.1654236,46.7,1.9439904242432768,9.089152471803377,5.061688539600905e-10,0.3510690307100617,999999.9847027273,4.14547787638093,-0.4882,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-320PEG1407,Trina Solar,Multi-c-Si,0,320.0,290.4,1.962176,1.978,0.992,72.0,9.07,45.9,8.6,37.2,0.00495222,-0.1383426,46.2,1.8462841808972423,9.070257182026417,1.447334960905068e-10,0.37495716113588945,13223.301818943526,12.416570874350514,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PEG1440,Trina Solar,Multi-c-Si,0,320.0,290.4,1.962176,1.978,0.992,72.0,9.07,45.9,8.6,37.2,0.00495222,-0.1383426,46.2,1.8462841808972423,9.070257182026417,1.447334960905068e-10,0.37495716113588945,13223.301818943526,12.416570874350514,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-320PEG1447,Trina Solar,Multi-c-Si,0,320.0,290.4,1.962176,1.978,0.992,72.0,9.07,45.9,8.6,37.2,0.00495222,-0.1383426,46.2,1.8462841808972423,9.070257182026417,1.447334960905068e-10,0.37495716113588945,13223.301818943526,12.416570874350514,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD05H(II),Trina Solar,Mono-c-Si,0,325.0,304.4,1.64,,,40.0,10.07,41.4,9.65,33.7,0.0030612800000000004,-0.114264,43.5,1.5063146958335918,10.070003041177696,1.166136602914123e-11,0.30199287476175884,999989.0524947575,-0.322683971768368,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-325DD05H08(II),Trina Solar,Mono-c-Si,0,325.0,304.4,1.64,,,40.0,10.07,41.4,9.65,33.7,0.0030612800000000004,-0.114264,43.5,1.5063146958335918,10.070003041177696,1.166136602914123e-11,0.30199287476175884,999989.0524947575,-0.322683971768368,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-325DD06H(II),Trina Solar,Mono-c-Si,0,325.0,305.1,1.664487,,,40.0,10.06,41.9,9.56,34.0,0.00430568,-0.1116635,43.3,1.5186860163071638,10.06294383894428,1.0450570439935905e-11,0.3405193197439015,1163.6589231498313,2.1835540273031637,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD06H05(II),Trina Solar,Mono-c-Si,0,325.0,301.6,1.66,,,40.0,10.06,41.9,9.56,34.0,0.0035914200000000005,-0.11325569999999999,46.3,1.5145900080136911,10.063072440325303,9.697908117633992e-12,0.3414511070324566,1118.0032374743641,0.22512341416487341,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD06H15(II),Trina Solar,Mono-c-Si,0,325.0,301.5,1.68493,,,40.0,10.06,41.9,9.56,34.0,0.0035914200000000005,-0.11325569999999999,46.3,1.5145900080136911,10.063072440325303,9.697908117633992e-12,0.3414511070324566,1118.0032374743641,0.22512341416487341,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD06M05(II),Trina Solar,Mono-c-Si,0,325.0,302.8,1.66,,,40.0,10.3,40.4,9.67,33.6,0.004995500000000001,-0.10863559999999998,45.6,1.4972131474217276,10.31215707601943,1.9295389525190705e-11,0.22238293364711892,188.41242715846698,6.216078457749442,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD06M15(II),Trina Solar,Mono-c-Si,0,325.0,302.7,1.68493,,,40.0,10.3,40.4,9.67,33.6,0.004995500000000001,-0.10863559999999998,45.6,1.4972131474217276,10.31215707601943,1.9295389525190705e-11,0.22238293364711892,188.41242715846698,6.216078457749442,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD06M18(II),Trina Solar,Mono-c-Si,0,325.0,303.1,1.68,,,40.0,10.3,40.4,9.67,33.6,0.004171500000000001,-0.10863559999999998,44.9,1.4941790361717961,10.312254118159006,1.8264875794778403e-11,0.22307878270382797,187.50521927435398,5.852555845874818,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD09M5C,Trina Solar,Mono-c-Si,0,325.0,301.3,1.92,,,64.0,9.16,45.0,8.74,37.2,0.0023815999999999998,-0.11682000000000001,45.31,1.6301179090786209,9.160007828673086,9.397932596804808e-12,0.3146736102500141,368080.4031298633,5.025149615748285,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD09M5CA0,Trina Solar,Mono-c-Si,0,325.0,301.3,1.92,,,64.0,9.16,45.0,8.74,37.2,0.0023815999999999998,-0.11682000000000001,45.31,1.6301179090786209,9.160007828673086,9.397932596804808e-12,0.3146736102500141,368080.4031298633,5.025149615748285,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD14A,Trina Solar,Mono-c-Si,0,325.0,298.5,1.9403519999999999,1.956,0.992,72.0,9.17,46.0,8.65,37.6,0.0049518,-0.13616,45.7,1.7866061033523255,9.176550402887601,5.974979078619921e-11,0.3472490632276,486.11880581549883,6.542168070706313,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD14A(II),Trina Solar,Mono-c-Si,0,325.0,298.5,1.9403519999999999,1.956,0.992,72.0,9.17,46.0,8.65,37.6,0.0049518,-0.13616,45.7,1.7866061033523255,9.176550402887601,5.974979078619921e-11,0.3472490632276,486.11880581549883,6.542168070706313,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD14A05,Trina Solar,Mono-c-Si,0,325.0,298.5,1.9403519999999999,1.956,0.992,72.0,9.17,46.0,8.65,37.6,0.0049518,-0.13616,45.7,1.7866061033523255,9.176550402887601,5.974979078619921e-11,0.3472490632276,486.11880581549883,6.542168070706313,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD14A05(II),Trina Solar,Mono-c-Si,0,325.0,298.5,1.9403519999999999,1.956,0.992,72.0,9.17,46.0,8.65,37.6,0.0049518,-0.13616,45.7,1.7866061033523255,9.176550402887601,5.974979078619921e-11,0.3472490632276,486.11880581549883,6.542168070706313,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD14A08,Trina Solar,Mono-c-Si,0,325.0,298.5,1.9403519999999999,1.956,0.992,72.0,9.17,46.0,8.65,37.6,0.0049518,-0.13616,45.7,1.7866061033523255,9.176550402887601,5.974979078619921e-11,0.3472490632276,486.11880581549883,6.542168070706313,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DD14A08(II),Trina Solar,Mono-c-Si,0,325.0,298.5,1.9403519999999999,1.956,0.992,72.0,9.17,46.0,8.65,37.6,0.0049518,-0.13616,45.7,1.7866061033523255,9.176550402887601,5.974979078619921e-11,0.3472490632276,486.11880581549883,6.542168070706313,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DE06H(II),Trina Solar,Mono-c-Si,0,325.0,305.1,1.664487,,,40.0,10.06,41.9,9.56,34.0,0.00430568,-0.1116635,43.3,1.5186860163071638,10.06294383894428,1.0450570439935905e-11,0.3405193197439015,1163.6589231498313,2.1835540273031637,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DE06H18(II),Trina Solar,Mono-c-Si,0,325.0,305.1,1.68,,,40.0,10.06,41.9,9.56,34.0,0.00430568,-0.1116635,43.3,1.5186860163071638,10.06294383894428,1.0450570439935905e-11,0.3405193197439015,1163.6589231498313,2.1835540273031637,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DE06HT0(II),Trina Solar,Mono-c-Si,0,325.0,305.2,1.66,,,40.0,10.06,41.9,9.56,34.0,0.00430568,-0.1116635,43.3,1.5186860163071638,10.06294383894428,1.0450570439935905e-11,0.3405193197439015,1163.6589231498313,2.1835540273031637,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DE06MT0(II),Trina Solar,Mono-c-Si,0,325.0,303.1,1.68,,,40.0,10.3,40.4,9.67,33.6,0.004171500000000001,-0.10863559999999998,44.9,1.4941790361717961,10.312254118159006,1.8264875794778403e-11,0.22307878270382797,187.50521927435398,5.852555845874818,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DEG6H20(II),Trina Solar,Mono-c-Si,0,325.0,304.9,1.6872239999999998,,,40.0,10.06,41.9,9.56,34.0,0.00465778,-0.1124596,43.4,1.5263281909658808,10.062705753540143,1.200165913799729e-11,0.33878336802423387,1259.597655216657,2.555716666362459,-0.3443,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325DEG6M20(II),Trina Solar,Mono-c-Si,0,325.0,304.3,1.6872239999999998,,,40.0,10.3,40.4,9.67,33.6,0.0041406,-0.11065559999999998,43.2,1.513793531701962,10.311633956221016,2.5943516796776287e-11,0.21858963335818124,193.52601969711117,6.902534707189528,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD14,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD14001,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD14002,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1400C,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,12.0,43.5,9.12,35.6,0.006,-0.135285,45.8,2.009499561823391,12.150115485017391,3.601287089205345e-09,0.17679324699303683,14.132579720570684,39.04179410662311,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1400M,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1400S,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1400U,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1405,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD14051,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD14052,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1405C,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,12.0,43.5,9.12,35.6,0.006,-0.135285,45.8,2.009499561823391,12.150115485017391,3.601287089205345e-09,0.17679324699303683,14.132579720570684,39.04179410662311,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1405M,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1405S,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1405U,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1408,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD14081,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1408C,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,12.0,43.5,9.12,35.6,0.006,-0.135285,45.8,2.009499561823391,12.150115485017391,3.601287089205345e-09,0.17679324699303683,14.132579720570684,39.04179410662311,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1408M,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1408S,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1408U,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1410,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1410C,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,12.0,43.5,9.12,35.6,0.006,-0.135285,45.8,2.009499561823391,12.150115485017391,3.601287089205345e-09,0.17679324699303683,14.132579720570684,39.04179410662311,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1415,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1418,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1418C,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,12.0,43.5,9.12,35.6,0.006,-0.135285,45.8,2.009499561823391,12.150115485017391,3.601287089205345e-09,0.17679324699303683,14.132579720570684,39.04179410662311,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PD1450,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PE14A,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PE14A05,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PE14A08,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PE14A10,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PE14A18,Trina Solar,Multi-c-Si,0,325.0,296.7,1.9403519999999999,1.956,0.992,72.0,9.15,46.1,8.66,37.6,0.004575000000000001,-0.143371,45.8,1.830795603523373,9.15282400537778,1.0566854969244345e-10,0.3487942649034403,1130.1211073716497,6.1872097096828265,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-325PEG14,Trina Solar,Multi-c-Si,0,325.0,295.0,1.962176,1.978,0.992,72.0,9.14,46.1,8.69,37.4,0.0049904400000000005,-0.1389454,46.2,1.856953953514651,9.140003269943486,1.5112007177608837e-10,0.35768176705710136,999999.9789420789,12.737572205897502,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-325PEG1407,Trina Solar,Multi-c-Si,0,325.0,295.0,1.962176,1.978,0.992,72.0,9.14,46.1,8.69,37.4,0.0049904400000000005,-0.1389454,46.2,1.856953953514651,9.140003269943486,1.5112007177608837e-10,0.35768176705710136,999999.9789420789,12.737572205897502,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-325PEG1440,Trina Solar,Multi-c-Si,0,325.0,295.0,1.962176,1.978,0.992,72.0,9.14,46.1,8.69,37.4,0.0049904400000000005,-0.1389454,46.2,1.856953953514651,9.140003269943486,1.5112007177608837e-10,0.35768176705710136,999999.9789420789,12.737572205897502,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-325PEG1447,Trina Solar,Multi-c-Si,0,325.0,295.0,1.962176,1.978,0.992,72.0,9.14,46.1,8.69,37.4,0.0049904400000000005,-0.1389454,46.2,1.856953953514651,9.140003269943486,1.5112007177608837e-10,0.35768176705710136,999999.9789420789,12.737572205897502,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-330DD05H(II),Trina Solar,Mono-c-Si,0,330.0,309.2,1.64,,,40.0,10.14,41.8,9.7,34.0,0.0030825600000000002,-0.115368,43.5,1.5192661620218886,10.140003170915694,1.1406943143276452e-11,0.31270505768761897,999998.1601829613,-0.5566781491235614,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-330DD05H08(II),Trina Solar,Mono-c-Si,0,330.0,309.2,1.64,,,40.0,10.14,41.8,9.7,34.0,0.0030825600000000002,-0.115368,43.5,1.5192661620218886,10.140003170915694,1.1406943143276452e-11,0.31270505768761897,999998.1601829613,-0.5566781491235614,-0.3547,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-330DD06H(II),Trina Solar,Mono-c-Si,0,330.0,309.9,1.664487,,,40.0,10.14,42.2,9.63,34.3,0.00433992,-0.11246300000000002,43.3,1.5312573094020059,10.14370073387867,1.0851019310755045e-11,0.33351726395994646,913.8363490976926,2.433874521823005,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD06H05(II),Trina Solar,Mono-c-Si,0,330.0,306.4,1.66,,,40.0,10.14,42.2,9.63,34.3,0.0036199800000000005,-0.1140666,46.3,1.5271237605566037,10.143829628939338,1.0069692088723131e-11,0.3344520736562533,885.5542284842811,0.47064688968408563,-0.3469,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-330DD06H15(II),Trina Solar,Mono-c-Si,0,330.0,306.3,1.68493,,,40.0,10.14,42.2,9.63,34.3,0.0036199800000000005,-0.1140666,46.3,1.5271237605566037,10.143829628939338,1.0069692088723131e-11,0.3344520736562533,885.5542284842811,0.47064688968408563,-0.3469,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-330DD06M05(II),Trina Solar,Mono-c-Si,0,330.0,307.5,1.66,,,40.0,10.39,40.6,9.76,33.8,0.00503915,-0.10917339999999999,45.6,1.5049776130652603,10.401692247226705,1.9598528362552263e-11,0.21762791556479386,193.38917579465826,6.2734458748045645,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD06M15(II),Trina Solar,Mono-c-Si,0,330.0,307.4,1.68493,,,40.0,10.39,40.6,9.76,33.8,0.00503915,-0.10917339999999999,45.6,1.5049776130652603,10.401692247226705,1.9598528362552263e-11,0.21762791556479386,193.38917579465826,6.2734458748045645,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD06M18(II),Trina Solar,Mono-c-Si,0,330.0,307.9,1.68,,,40.0,10.39,40.6,9.76,33.8,0.00420795,-0.10917339999999999,44.9,1.501925915297608,10.401787912384469,1.855144446626158e-11,0.21832176052201202,192.43128200590377,5.9094136642512645,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD09M5C,Trina Solar,Mono-c-Si,0,330.0,306.0,1.92,,,64.0,9.26,45.2,8.83,37.4,0.0024075999999999998,-0.1173392,45.31,1.6375518545981544,9.260007079488103,9.530855364221782e-12,0.3083684753606484,403349.8157634294,5.052287942927958,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD09M5CA0,Trina Solar,Mono-c-Si,0,330.0,306.0,1.92,,,64.0,9.26,45.2,8.83,37.4,0.0024075999999999998,-0.1173392,45.31,1.6375518545981544,9.260007079488103,9.530855364221782e-12,0.3083684753606484,403349.8157634294,5.052287942927958,-0.353,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A,Trina Solar,Mono-c-Si,0,330.0,303.2,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.72,37.8,0.0050057999999999995,-0.136752,45.7,1.7978055554614758,9.27879706012,6.322886500099577e-11,0.3399672113484535,358.24424458804697,6.947590664052501,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A(II),Trina Solar,Mono-c-Si,0,330.0,303.2,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.72,37.8,0.0050057999999999995,-0.136752,45.7,1.7978055554614758,9.27879706012,6.322886500099577e-11,0.3399672113484535,358.24424458804697,6.947590664052501,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A05,Trina Solar,Mono-c-Si,0,330.0,303.2,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.72,37.8,0.0050057999999999995,-0.136752,45.7,1.7978055554614758,9.27879706012,6.322886500099577e-11,0.3399672113484535,358.24424458804697,6.947590664052501,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A05(II),Trina Solar,Mono-c-Si,0,330.0,303.2,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.72,37.8,0.0050057999999999995,-0.136752,45.7,1.7978055554614758,9.27879706012,6.322886500099577e-11,0.3399672113484535,358.24424458804697,6.947590664052501,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A08,Trina Solar,Mono-c-Si,0,330.0,303.2,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.72,37.8,0.0050057999999999995,-0.136752,45.7,1.7978055554614758,9.27879706012,6.322886500099577e-11,0.3399672113484535,358.24424458804697,6.947590664052501,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A08(II),Trina Solar,Mono-c-Si,0,330.0,303.2,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.72,37.8,0.0050057999999999995,-0.136752,45.7,1.7978055554614758,9.27879706012,6.322886500099577e-11,0.3399672113484535,358.24424458804697,6.947590664052501,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A10(II),Trina Solar,Mono-c-Si,0,330.0,296.9,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.73,37.8,0.00479259,-0.1604988,46.3,1.9571728572063256,9.274241509938093,5.155282882492696e-10,0.30135949433469444,658.6342196139528,7.815978185957235,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A15(II),Trina Solar,Mono-c-Si,0,330.0,296.9,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.73,37.8,0.00479259,-0.1604988,46.3,1.9571728572063256,9.274241509938093,5.155282882492696e-10,0.30135949433469444,658.6342196139528,7.815978185957235,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD14A18(II),Trina Solar,Mono-c-Si,0,330.0,296.9,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.73,37.8,0.00479259,-0.1604988,46.3,1.9571728572063256,9.274241509938093,5.155282882492696e-10,0.30135949433469444,658.6342196139528,7.815978185957235,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD151M(II),Trina Solar,Mono-c-Si,0,330.0,306.3,1.9227,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD151M08(II),Trina Solar,Mono-c-Si,0,330.0,306.3,1.9227,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD151MT0(II),Trina Solar,Mono-c-Si,0,330.0,306.3,1.9227,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DD151MT8(II),Trina Solar,Mono-c-Si,0,330.0,306.3,1.9227,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE06H(II),Trina Solar,Mono-c-Si,0,330.0,309.9,1.664487,,,40.0,10.14,42.2,9.63,34.3,0.00433992,-0.11246300000000002,43.3,1.5312573094020059,10.14370073387867,1.0851019310755045e-11,0.33351726395994646,913.8363490976926,2.433874521823005,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE06H18(II),Trina Solar,Mono-c-Si,0,330.0,309.9,1.68,,,40.0,10.14,42.2,9.63,34.3,0.00433992,-0.11246300000000002,43.3,1.5312573094020059,10.14370073387867,1.0851019310755045e-11,0.33351726395994646,913.8363490976926,2.433874521823005,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE06HT0(II),Trina Solar,Mono-c-Si,0,330.0,310.0,1.66,,,40.0,10.14,42.2,9.63,34.3,0.00433992,-0.11246300000000002,43.3,1.5312573094020059,10.14370073387867,1.0851019310755045e-11,0.33351726395994646,913.8363490976926,2.433874521823005,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE06MT0(II),Trina Solar,Mono-c-Si,0,330.0,307.0,1.66,,,40.0,10.39,40.6,9.76,33.8,0.00400015,-0.147784,45.4,1.529197502227956,10.40094748162155,3.006814826332835e-11,0.2121397385359138,201.33688868636753,-18.747641665254775,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE14A(II),Trina Solar,Multi-c-Si,0,330.0,296.9,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.73,37.8,0.00479259,-0.1604988,46.3,1.9571728572063256,9.274241509938093,5.155282882492696e-10,0.30135949433469444,658.6342196139528,7.815978185957235,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE14A08(II),Trina Solar,Multi-c-Si,0,330.0,296.9,1.9403519999999999,1.956,0.992,72.0,9.27,46.2,8.73,37.8,0.00479259,-0.1604988,46.3,1.9571728572063256,9.274241509938093,5.155282882492696e-10,0.30135949433469444,658.6342196139528,7.815978185957235,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE151M(II),Trina Solar,Mono-c-Si,0,330.0,306.2,1.93,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE151M08(II),Trina Solar,Mono-c-Si,0,330.0,306.2,1.93,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE151MT0(II),Trina Solar,Mono-c-Si,0,330.0,306.2,1.93,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DE151MT8(II),Trina Solar,Mono-c-Si,0,330.0,306.2,1.93,,,60.0,10.39,40.6,9.76,33.8,0.00347026,-0.11087860000000001,44.88,1.5089086499369577,10.401569620240647,2.1028020871511508e-11,0.2167349149304321,194.63696589655848,5.428369742185933,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DEG6H20(II),Trina Solar,Mono-c-Si,0,330.0,309.7,1.6872239999999998,,,40.0,10.14,42.2,9.63,34.3,0.004694820000000001,-0.11326480000000003,43.4,1.5389730646245023,10.143462008810333,1.2461915543370361e-11,0.33177488391787757,971.7472144781543,2.807042524496572,-0.3443,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330DEG6M20(II),Trina Solar,Mono-c-Si,0,330.0,309.1,1.6872239999999998,,,40.0,10.39,40.6,9.76,33.8,0.004176780000000001,-0.1112034,43.2,1.5216461636027294,10.401176935317366,2.6350281894795912e-11,0.21384733886237367,198.79097469431528,6.959759899579793,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD14,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD14001,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD14002,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1400M,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1400S,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1400U,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1405,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD14051,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD14052,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1405M,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1405S,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1405U,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1408,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD14081,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1408M,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1408S,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1408U,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1410,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1415,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1418,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PD1450,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PE14A,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PE14A05,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PE14A08,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PE14A10,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PE14A18,Trina Solar,Multi-c-Si,0,330.0,301.4,1.9403519999999999,1.956,0.992,72.0,9.21,46.5,8.73,37.8,0.004605000000000001,-0.144615,45.8,1.841923610572506,9.21144016891698,9.987950797676294e-11,0.3664960460751387,2343.77349635474,5.643542934033959,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PE14H,Trina Solar,Multi-c-Si,0,330.0,305.3,1.96,,,48.0,9.28,45.8,8.83,37.4,0.00506688,-0.136484,45.4,1.7248221822161849,9.280485416429928,2.724177348415415e-11,0.35789548441873803,6842.106999210255,-0.8176376201601037,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PEG14,Trina Solar,Multi-c-Si,0,330.0,302.6,1.962,1.978,0.992,72.0,9.31,45.8,8.78,37.6,0.00364952,-0.14637679999999997,44.3,1.833931365554237,9.315510150989754,1.3156388349350863e-10,0.30655240781576865,517.9537020697711,5.152883287196307,-0.4211,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-330PEG1407,Trina Solar,Multi-c-Si,0,330.0,299.7,1.962176,1.978,0.992,72.0,9.23,46.2,8.78,37.6,0.005039580000000001,-0.1392468,46.2,1.8640880661715227,9.230003121342378,1.5905319769867783e-10,0.33809857806822663,999999.9764937218,13.114256625446526,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-330PEG1440,Trina Solar,Multi-c-Si,0,330.0,299.7,1.962176,1.978,0.992,72.0,9.23,46.2,8.78,37.6,0.005039580000000001,-0.1392468,46.2,1.8640880661715227,9.230003121342378,1.5905319769867783e-10,0.33809857806822663,999999.9764937218,13.114256625446526,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-330PEG1447,Trina Solar,Multi-c-Si,0,330.0,299.7,1.962176,1.978,0.992,72.0,9.23,46.2,8.78,37.6,0.005039580000000001,-0.1392468,46.2,1.8640880661715227,9.230003121342378,1.5905319769867783e-10,0.33809857806822663,999999.9764937218,13.114256625446526,-0.4246,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-330PEG15H20(II),Trina Solar,Multi-c-Si,0,330.0,303.8,2.03,,,48.0,9.35,45.8,8.87,37.2,0.00391765,-0.13671299999999997,45.6,1.726154790246958,9.352757260836187,2.793628796951978e-11,0.38039384404687154,1289.9331676037207,-0.6688568103057573,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD06H(II),Trina Solar,Mono-c-Si,0,335.0,314.7,1.664487,,,40.0,10.2,42.6,9.69,34.6,0.0043656,-0.11352900000000002,43.3,1.5449916872046607,10.203364482211953,1.0769176152396508e-11,0.3376706188092612,1023.7056745847639,2.320092987836618,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD06H05(II),Trina Solar,Mono-c-Si,0,335.0,311.2,1.66,,,40.0,10.2,42.6,9.69,34.6,0.0036414,-0.11514780000000001,46.3,1.5408226489694532,10.20349435966976,9.99364771201223e-12,0.33860702801551845,988.390462107519,0.35903204953922024,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD06H15(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.68493,,,40.0,10.2,42.6,9.69,34.6,0.0036414,-0.11514780000000001,46.3,1.5408226489694532,10.20349435966976,9.99364771201223e-12,0.33860702801551845,988.390462107519,0.35903204953922024,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD06M05(II),Trina Solar,Mono-c-Si,0,335.0,312.4,1.68,,,40.0,10.48,40.7,9.85,34.0,0.00650808,-0.1087911,46.8,1.4962994794971671,10.49127070700406,1.5810405027140564e-11,0.20601621859291916,191.56295872879764,4.809002170889286,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD06M15(II),Trina Solar,Mono-c-Si,0,335.0,312.2,1.68493,,,40.0,10.48,40.7,9.85,34.0,0.0050828,-0.10944229999999999,45.6,1.5109307106169054,10.490829193223172,2.0583886248520672e-11,0.20270742688700868,196.17101684611364,6.621432588654483,-0.3413,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD06M18(II),Trina Solar,Mono-c-Si,0,335.0,312.7,1.68,,,40.0,10.48,40.7,9.85,34.0,0.004244400000000001,-0.10944229999999999,44.9,1.5078609151102533,10.490921050681255,1.948364907350347e-11,0.2034006559352094,195.18622050308505,6.255484723753937,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD14A(II),Trina Solar,Mono-c-Si,0,335.0,308.0,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.86,38.0,0.0050544,-0.13704799999999998,45.7,1.799081025090257,9.363887864765433,6.193761699039598e-11,0.32229737373892264,775.9279926092157,6.66295290589835,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD14A05(II),Trina Solar,Mono-c-Si,0,335.0,308.0,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.86,38.0,0.0050544,-0.13704799999999998,45.7,1.799081025090257,9.363887864765433,6.193761699039598e-11,0.32229737373892264,775.9279926092157,6.66295290589835,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD14A08(II),Trina Solar,Mono-c-Si,0,335.0,308.0,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.86,38.0,0.0050544,-0.13704799999999998,45.7,1.799081025090257,9.363887864765433,6.193761699039598e-11,0.32229737373892264,775.9279926092157,6.66295290589835,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD14A10(II),Trina Solar,Mono-c-Si,0,335.0,301.6,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.84,37.9,0.004839120000000001,-0.1608462,46.3,1.95891432537915,9.362259118018832,5.068124546368281e-10,0.2970997314375959,1230.9473958873161,7.573102413206159,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD14A15(II),Trina Solar,Mono-c-Si,0,335.0,301.6,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.84,37.9,0.004839120000000001,-0.1608462,46.3,1.95891432537915,9.362259118018832,5.068124546368281e-10,0.2970997314375959,1230.9473958873161,7.573102413206159,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD14A18(II),Trina Solar,Mono-c-Si,0,335.0,301.6,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.84,37.9,0.004839120000000001,-0.1608462,46.3,1.95891432537915,9.362259118018832,5.068124546368281e-10,0.2970997314375959,1230.9473958873161,7.573102413206159,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD151M(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.9227,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD151M08(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.9227,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD151MT0(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.9227,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DD151MT8(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.9227,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE06H(II),Trina Solar,Mono-c-Si,0,335.0,314.7,1.664487,,,40.0,10.2,42.6,9.69,34.6,0.0043656,-0.11352900000000002,43.3,1.5449916872046607,10.203364482211953,1.0769176152396508e-11,0.3376706188092612,1023.7056745847639,2.320092987836618,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE06H18(II),Trina Solar,Mono-c-Si,0,335.0,314.7,1.68,,,40.0,10.2,42.6,9.69,34.6,0.0043656,-0.11352900000000002,43.3,1.5449916872046607,10.203364482211953,1.0769176152396508e-11,0.3376706188092612,1023.7056745847639,2.320092987836618,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE06HT0(II),Trina Solar,Mono-c-Si,0,335.0,314.8,1.66,,,40.0,10.2,42.6,9.69,34.6,0.0043656,-0.11352900000000002,43.3,1.5449916872046607,10.203364482211953,1.0769176152396508e-11,0.3376706188092612,1023.7056745847639,2.320092987836618,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE06MT0(II),Trina Solar,Mono-c-Si,0,335.0,312.7,1.68,,,40.0,10.48,40.7,9.85,34.0,0.004244400000000001,-0.10944229999999999,44.9,1.5078609151102533,10.490921050681255,1.948364907350347e-11,0.2034006559352094,195.18622050308505,6.255484723753937,-0.3468,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE14A(II),Trina Solar,Multi-c-Si,0,335.0,301.6,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.84,37.9,0.004839120000000001,-0.1608462,46.3,1.95891432537915,9.362259118018832,5.068124546368281e-10,0.2970997314375959,1230.9473958873161,7.573102413206159,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE14A08(II),Trina Solar,Multi-c-Si,0,335.0,301.6,1.9403519999999999,1.956,0.992,72.0,9.36,46.3,8.84,37.9,0.004839120000000001,-0.1608462,46.3,1.95891432537915,9.362259118018832,5.068124546368281e-10,0.2970997314375959,1230.9473958873161,7.573102413206159,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE151M(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.93,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE151M08(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.93,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE151MT0(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.93,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DE151MT8(II),Trina Solar,Mono-c-Si,0,335.0,311.0,1.93,,,60.0,10.48,40.7,9.85,34.0,0.00350032,-0.1111517,44.88,1.5148815829488542,10.490711577258356,2.2084609650114425e-11,0.20181600488017057,197.45287676931545,5.772023892688745,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DEG6H20(II),Trina Solar,Mono-c-Si,0,335.0,314.5,1.6872239999999998,,,40.0,10.2,42.6,9.69,34.6,0.0047225999999999995,-0.11433840000000002,43.4,1.55277194903037,10.203123986353436,1.2367763151450097e-11,0.3359256450042458,1096.817111557344,2.6928120778768627,-0.3443,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335DEG6M20(II),Trina Solar,Mono-c-Si,0,335.0,313.9,1.6872239999999998,,,40.0,10.48,40.7,9.85,34.0,0.00421296,-0.1114773,43.2,1.5276859260578806,10.490335065891829,2.7672890435820156e-11,0.1989329565895869,201.72270044143698,7.30804653263863,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PD14,Trina Solar,Multi-c-Si,0,335.0,307.4,1.92,,,72.0,9.35,46.0,8.91,37.6,0.0041514,-0.13031800000000002,46.4,1.7534299280600198,9.350003895326712,3.779193892549963e-11,0.3468995584593871,832710.5133401182,7.2308872104194775,-0.3815,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PD1410,Trina Solar,Multi-c-Si,0,335.0,307.4,1.92,,,72.0,9.35,46.0,8.91,37.6,0.0041514,-0.13031800000000002,46.4,1.7534299280600198,9.350003895326712,3.779193892549963e-11,0.3468995584593871,832710.5133401182,7.2308872104194775,-0.3815,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PE14A,Trina Solar,Multi-c-Si,0,335.0,307.4,1.92,,,72.0,9.35,46.0,8.91,37.6,0.0041514,-0.13031800000000002,46.4,1.7534299280600198,9.350003895326712,3.779193892549963e-11,0.3468995584593871,832710.5133401182,7.2308872104194775,-0.3815,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PE14H,Trina Solar,Multi-c-Si,0,335.0,310.0,1.96,,,48.0,9.45,45.9,8.96,37.4,0.005159700000000001,-0.136782,45.4,1.7295499278231636,9.453497453056757,2.8043122210213086e-11,0.3627284564519704,980.0800839263217,-0.7180609456623444,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PEG14,Trina Solar,Multi-c-Si,0,335.0,307.3,1.962,,,72.0,9.35,46.0,8.87,37.8,0.0036652,-0.147016,44.3,1.8373138343775557,9.351257379805554,1.2493483983760974e-10,0.3024724351083449,2249.215602490851,4.657577754816796,-0.4211,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PEG1440,Trina Solar,Multi-c-Si,0,335.0,307.3,1.962,,,72.0,9.35,46.0,8.87,37.8,0.0036652,-0.147016,44.3,1.8373138343775557,9.351257379805554,1.2493483983760974e-10,0.3024724351083449,2249.215602490851,4.657577754816796,-0.4211,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-335PEG15H20(II),Trina Solar,Multi-c-Si,0,335.0,308.6,2.03,,,48.0,9.45,45.9,8.96,37.4,0.00395955,-0.1370115,45.6,1.7332649467189158,9.453405513996106,2.9687754521655727e-11,0.3618364442851848,1004.0641696868154,-0.26238343360168825,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD06M05(II),Trina Solar,Mono-c-Si,0,340.0,317.2,1.68,,,40.0,10.55,41.1,9.94,34.2,0.006551550000000001,-0.10986030000000001,46.8,1.506221918169201,10.560231285639832,1.4646235975441073e-11,0.22239571045916168,229.32355136071664,4.090128377360054,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD14A(II),Trina Solar,Mono-c-Si,0,340.0,312.7,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.005103,-0.13764,45.7,1.8123410748421933,9.457760331909634,6.719215293036165e-11,0.3155397393862588,384.2426686141667,7.3037802021465925,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD14A05(II),Trina Solar,Mono-c-Si,0,340.0,312.7,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.005103,-0.13764,45.7,1.8123410748421933,9.457760331909634,6.719215293036165e-11,0.3155397393862588,384.2426686141667,7.3037802021465925,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD14A08(II),Trina Solar,Mono-c-Si,0,340.0,312.7,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.005103,-0.13764,45.7,1.8123410748421933,9.457760331909634,6.719215293036165e-11,0.3155397393862588,384.2426686141667,7.3037802021465925,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD14A10(II),Trina Solar,Mono-c-Si,0,340.0,306.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.00488565,-0.161541,46.3,1.974458906410765,9.454227096891403,5.548817269558913e-10,0.2770748165595768,619.4222736241286,8.291724009351409,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD14A15(II),Trina Solar,Mono-c-Si,0,340.0,306.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.00488565,-0.161541,46.3,1.974458906410765,9.454227096891403,5.548817269558913e-10,0.2770748165595768,619.4222736241286,8.291724009351409,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD14A18(II),Trina Solar,Mono-c-Si,0,340.0,306.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.00488565,-0.161541,46.3,1.974458906410765,9.454227096891403,5.548817269558913e-10,0.2770748165595768,619.4222736241286,8.291724009351409,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD151M(II),Trina Solar,Mono-c-Si,0,340.0,315.8,1.9227,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD151M08(II),Trina Solar,Mono-c-Si,0,340.0,315.8,1.9227,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD151MT0(II),Trina Solar,Mono-c-Si,0,340.0,315.8,1.9227,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DD151MT8(II),Trina Solar,Mono-c-Si,0,340.0,315.8,1.9227,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE06HT0(II),Trina Solar,Mono-c-Si,0,340.0,319.6,1.66,,,40.0,10.26,43.0,9.75,34.9,0.00439128,-0.114595,43.3,1.5587253120280342,10.263020814574592,1.0689998811653543e-11,0.34177336148615645,1160.8110018154364,2.2083270467635128,-0.3433,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE06MT0(II),Trina Solar,Mono-c-Si,0,340.0,316.5,1.66,,,40.0,10.55,41.1,9.94,34.2,0.00406175,-0.14960400000000001,45.4,1.5452292441739444,10.559091251440003,2.920072834875728e-11,0.2137098311866414,248.0009224045097,-19.04881400088645,-0.3536,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE14A(II),Trina Solar,Multi-c-Si,0,340.0,306.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.00488565,-0.161541,46.3,1.974458906410765,9.454227096891403,5.548817269558913e-10,0.2770748165595768,619.4222736241286,8.291724009351409,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE14A08(II),Trina Solar,Multi-c-Si,0,340.0,306.2,1.9403519999999999,1.956,0.992,72.0,9.45,46.5,8.9,38.2,0.00488565,-0.161541,46.3,1.974458906410765,9.454227096891403,5.548817269558913e-10,0.2770748165595768,619.4222736241286,8.291724009351409,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE151M(II),Trina Solar,Mono-c-Si,0,340.0,315.7,1.93,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE151M08(II),Trina Solar,Mono-c-Si,0,340.0,315.7,1.93,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE151MT0(II),Trina Solar,Mono-c-Si,0,340.0,315.7,1.93,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DE151MT8(II),Trina Solar,Mono-c-Si,0,340.0,315.7,1.93,,,60.0,10.55,41.1,9.94,34.2,0.0035237000000000003,-0.11224410000000001,44.88,1.5248812151100988,10.559677762623545,2.046362493951581e-11,0.21823041189715817,237.89908393487798,5.053642765939521,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DEG14(II),Trina Solar,Mono-c-Si,0,340.0,309.0,1.962176,1.978,0.992,72.0,9.45,46.5,8.9,38.2,0.005159700000000001,-0.140151,46.2,1.890793713798311,9.455955046525954,1.952580715863372e-10,0.29676622101212,470.93521261896825,14.81704863802467,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DEG1407(II),Trina Solar,Mono-c-Si,0,340.0,309.0,1.962176,1.978,0.992,72.0,9.45,46.5,8.9,38.2,0.005159700000000001,-0.140151,46.2,1.890793713798311,9.455955046525954,1.952580715863372e-10,0.29676622101212,470.93521261896825,14.81704863802467,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DEG1440(II),Trina Solar,Mono-c-Si,0,340.0,309.0,1.962176,1.978,0.992,72.0,9.45,46.5,8.9,38.2,0.005159700000000001,-0.140151,46.2,1.890793713798311,9.455955046525954,1.952580715863372e-10,0.29676622101212,470.93521261896825,14.81704863802467,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DEG1447(II),Trina Solar,Mono-c-Si,0,340.0,309.0,1.962176,1.978,0.992,72.0,9.45,46.5,8.9,38.2,0.005159700000000001,-0.140151,46.2,1.890793713798311,9.455955046525954,1.952580715863372e-10,0.29676622101212,470.93521261896825,14.81704863802467,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340DEG6M20(II),Trina Solar,Mono-c-Si,0,340.0,318.7,1.6872239999999998,,,40.0,10.55,41.1,9.94,34.2,0.0042411,-0.1125729,43.2,1.5377390800559285,10.559305082474113,2.564654950197203e-11,0.21537125689829037,244.1855606819766,6.581125767861481,-0.3577,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340PE14A,Trina Solar,Multi-c-Si,0,340.0,312.1,1.92,,,72.0,9.48,46.4,9.0,37.8,0.00420912,-0.1314512,46.4,1.7666269842818,9.4818864806859,3.7075951618272444e-11,0.3618263742940728,1818.26104745806,6.955157883989027,-0.3815,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340PE14H,Trina Solar,Multi-c-Si,0,340.0,314.8,1.96,,,48.0,9.5,46.1,9.05,37.6,0.005187000000000001,-0.137378,45.4,1.735154486058992,9.500004171266662,2.749675139944594e-11,0.35742698580195276,814067.4473970648,-0.9330362699579883,-0.3596,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340PE15H,Trina Solar,Multi-c-Si,0,340.0,315.5,1.99,,,48.0,9.53,46.2,9.06,37.5,0.0042885,-0.13665960000000002,44.3,1.7312772141037125,9.530946465537482,2.450313505668265e-11,0.3814151610084277,3840.485484524565,-1.0144197335106109,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340PE15HT0,Trina Solar,Multi-c-Si,0,340.0,315.5,1.99,,,48.0,9.53,46.2,9.06,37.5,0.0042885,-0.137907,44.3,1.7319876507227128,9.530928871837375,2.477334229128183e-11,0.3812468564129694,3911.500858009847,-1.8279850563271132,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-340PEG15H20(II),Trina Solar,Multi-c-Si,0,340.0,313.3,2.03,,,48.0,9.53,46.2,9.06,37.5,0.00399307,-0.137907,45.6,1.7388585172267377,9.530759521241203,2.7532666520158287e-11,0.37962046267831223,4763.242595512079,-0.9467198481697908,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD06M05(II),Trina Solar,Mono-c-Si,0,345.0,321.9,1.68,,,40.0,10.7,41.2,10.03,34.4,0.0066447,-0.1101276,46.8,1.5162542844280777,10.713440534163954,1.6553053158134494e-11,0.20602145233981695,164.01353709800725,5.0342529413166925,-0.3204,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD14A(II),Trina Solar,Mono-c-Si,0,345.0,317.4,1.9403519999999999,1.956,0.992,72.0,9.5,46.8,9.03,38.4,0.00513,-0.13852799999999998,45.7,1.8145185348437185,9.500696346329708,5.969811873709073e-11,0.3225935245292294,4401.029248351131,6.202407846228697,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD14A05(II),Trina Solar,Mono-c-Si,0,345.0,317.4,1.9403519999999999,1.956,0.992,72.0,9.5,46.8,9.03,38.4,0.00513,-0.13852799999999998,45.7,1.8145185348437185,9.500696346329708,5.969811873709073e-11,0.3225935245292294,4401.029248351131,6.202407846228697,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD14A08(II),Trina Solar,Mono-c-Si,0,345.0,317.4,1.9403519999999999,1.956,0.992,72.0,9.5,46.8,9.03,38.4,0.00513,-0.13852799999999998,45.7,1.8145185348437185,9.500696346329708,5.969811873709073e-11,0.3225935245292294,4401.029248351131,6.202407846228697,-0.385,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD14A10(II),Trina Solar,Mono-c-Si,0,345.0,310.9,1.9403519999999999,1.956,0.992,72.0,9.5,46.7,9.0,38.4,0.0049115,-0.1622358,46.3,1.976703669578259,9.500006084596684,5.217100222094713e-10,0.27331649672226394,426833.92371949286,7.684051655375977,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD14A15(II),Trina Solar,Mono-c-Si,0,345.0,310.9,1.9403519999999999,1.956,0.992,72.0,9.5,46.7,9.0,38.4,0.0049115,-0.1622358,46.3,1.976703669578259,9.500006084596684,5.217100222094713e-10,0.27331649672226394,426833.92371949286,7.684051655375977,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD14A18(II),Trina Solar,Mono-c-Si,0,345.0,310.9,1.9403519999999999,1.956,0.992,72.0,9.5,46.7,9.0,38.4,0.0049115,-0.1622358,46.3,1.976703669578259,9.500006084596684,5.217100222094713e-10,0.27331649672226394,426833.92371949286,7.684051655375977,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD151M(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.9227,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD151M08(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.9227,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD151MT0(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.9227,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DD151MT8(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.9227,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DE14A(II),Trina Solar,Multi-c-Si,0,345.0,310.9,1.9403519999999999,1.956,0.992,72.0,9.5,46.7,9.0,38.4,0.0049115,-0.1622358,46.3,1.976703669578259,9.500006084596684,5.217100222094713e-10,0.27331649672226394,426833.92371949286,7.684051655375977,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DE14A08(II),Trina Solar,Multi-c-Si,0,345.0,310.9,1.9403519999999999,1.956,0.992,72.0,9.5,46.7,9.0,38.4,0.0049115,-0.1622358,46.3,1.976703669578259,9.500006084596684,5.217100222094713e-10,0.27331649672226394,426833.92371949286,7.684051655375977,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DE151M(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.93,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DE151M08(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.93,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DE151MT0(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.93,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DE151MT8(II),Trina Solar,Mono-c-Si,0,345.0,320.5,1.93,,,60.0,10.56,41.2,10.0,34.5,0.0035270400000000004,-0.11251720000000001,44.88,1.529715610969,10.565623744395563,2.1004946543803647e-11,0.19407216068873298,364.41948520708763,5.247453053795911,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DEG14(II),Trina Solar,Mono-c-Si,0,345.0,313.7,1.962176,1.978,0.992,72.0,9.5,46.7,9.0,38.4,0.005187000000000001,-0.1407538,46.2,1.8941642165089778,9.501786739276659,1.8579850743787611e-10,0.2925386953893058,1555.4133228370256,14.285429546079737,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DEG1407(II),Trina Solar,Mono-c-Si,0,345.0,313.7,1.962176,1.978,0.992,72.0,9.5,46.7,9.0,38.4,0.005187000000000001,-0.1407538,46.2,1.8941642165089778,9.501786739276659,1.8579850743787611e-10,0.2925386953893058,1555.4133228370256,14.285429546079737,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DEG1440(II),Trina Solar,Mono-c-Si,0,345.0,313.7,1.962176,1.978,0.992,72.0,9.5,46.7,9.0,38.4,0.005187000000000001,-0.1407538,46.2,1.8941642165089778,9.501786739276659,1.8579850743787611e-10,0.2925386953893058,1555.4133228370256,14.285429546079737,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DEG1447(II),Trina Solar,Mono-c-Si,0,345.0,313.7,1.962176,1.978,0.992,72.0,9.5,46.7,9.0,38.4,0.005187000000000001,-0.1407538,46.2,1.8941642165089778,9.501786739276659,1.8579850743787611e-10,0.2925386953893058,1555.4133228370256,14.285429546079737,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345DEG14C07(II),Trina Solar,Mono-c-Si,1,345.0,316.7,1.962,,,72.0,9.47,47.4,8.85,39.0,0.00357966,-0.13674899999999998,44.4,1.8953869521638786,9.482284393679732,1.2783132602537724e-10,0.3027818937230058,233.4136070464202,16.18294685930436,-0.4196,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345PE14H,Trina Solar,Multi-c-Si,0,345.0,319.5,1.96,,,48.0,9.55,46.3,9.14,37.8,0.005214300000000001,-0.13797399999999999,45.4,1.7470902389885843,9.550003134480653,2.95578923027276e-11,0.32820175008090224,999998.1745997369,-0.39398294505122616,-0.3596,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-345PE15H,Trina Solar,Multi-c-Si,0,345.0,320.3,1.99,,,48.0,9.62,46.4,9.15,37.7,0.0043289999999999995,-0.138504,44.3,1.7399919353955435,9.620550472990663,2.521389446488634e-11,0.37453822722210156,6545.387239788594,-1.7641640219369368,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345PE15HT0,Trina Solar,Multi-c-Si,0,345.0,320.3,1.99,,,48.0,9.62,46.4,9.15,37.7,0.0043289999999999995,-0.138504,44.3,1.7399919353955435,9.620550472990663,2.521389446488634e-11,0.37453822722210156,6545.387239788594,-1.7641640219369368,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-345PEG15H20(II),Trina Solar,Multi-c-Si,0,345.0,318.0,2.03,,,48.0,9.62,46.4,9.15,37.7,0.004030779999999999,-0.138504,45.6,1.7468940707549905,9.620383620507,2.8021217678323324e-11,0.3729194284174107,9351.605648003893,-0.8827239437876317,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD14A(II),Trina Solar,Mono-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD14A05(II),Trina Solar,Mono-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD14A08(II),Trina Solar,Mono-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD14A10(II),Trina Solar,Mono-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD14A15(II),Trina Solar,Mono-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD14A18(II),Trina Solar,Mono-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD151M(II),Trina Solar,Mono-c-Si,0,350.0,325.3,1.9227,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD151M08(II),Trina Solar,Mono-c-Si,0,350.0,325.3,1.9227,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD151MT0(II),Trina Solar,Mono-c-Si,0,350.0,325.3,1.9227,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DD151MT8(II),Trina Solar,Mono-c-Si,0,350.0,325.3,1.9227,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE14A(II),Trina Solar,Multi-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE14A08(II),Trina Solar,Multi-c-Si,0,350.0,315.5,1.9403519999999999,1.956,0.992,72.0,9.6,46.9,9.09,38.5,0.0049632,-0.16293059999999998,46.3,1.9848275801550406,9.600608390062032,5.245199844266563e-10,0.2796779072690554,4413.146608790056,7.642965585659264,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE14H(II),Trina Solar,Mono-c-Si,0,350.0,326.0,1.96,,,48.0,9.6,46.5,9.13,38.4,0.0043296,-0.1275495,44.4,1.724614325362484,9.602234151670727,1.866734949762704e-11,0.3059066948437787,1314.4603786371058,4.4123635693416245,-0.3529,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE151M(II),Trina Solar,Mono-c-Si,0,350.0,325.2,1.93,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE151M08(II),Trina Solar,Mono-c-Si,0,350.0,325.2,1.93,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE151MT0(II),Trina Solar,Mono-c-Si,0,350.0,325.2,1.93,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DE151MT8(II),Trina Solar,Mono-c-Si,0,350.0,325.2,1.93,,,60.0,10.6,41.2,10.1,34.6,0.0035404,-0.11251720000000001,44.88,1.5273816997102723,10.601704444005952,2.0375693908549394e-11,0.1826349849661302,1135.8137174820417,4.930369991901454,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DEG14(II),Trina Solar,Mono-c-Si,0,350.0,318.4,1.962176,1.978,0.992,72.0,9.6,46.9,9.09,38.5,0.005241600000000001,-0.1413566,46.2,1.9010437655488737,9.602131526693805,1.8469656804344335e-10,0.2989521611979483,1346.425307642892,14.135694164556451,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DEG1407(II),Trina Solar,Mono-c-Si,0,350.0,318.4,1.962176,1.978,0.992,72.0,9.6,46.9,9.09,38.5,0.005241600000000001,-0.1413566,46.2,1.9010437655488737,9.602131526693805,1.8469656804344335e-10,0.2989521611979483,1346.425307642892,14.135694164556451,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DEG1440(II),Trina Solar,Mono-c-Si,0,350.0,318.4,1.962176,1.978,0.992,72.0,9.6,46.9,9.09,38.5,0.005241600000000001,-0.1413566,46.2,1.9010437655488737,9.602131526693805,1.8469656804344335e-10,0.2989521611979483,1346.425307642892,14.135694164556451,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DEG1447(II),Trina Solar,Mono-c-Si,0,350.0,318.4,1.962176,1.978,0.992,72.0,9.6,46.9,9.09,38.5,0.005241600000000001,-0.1413566,46.2,1.9010437655488737,9.602131526693805,1.8469656804344335e-10,0.2989521611979483,1346.425307642892,14.135694164556451,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DEG14C07(II),Trina Solar,Mono-c-Si,1,350.0,321.4,1.962,,,72.0,9.54,47.6,8.93,39.2,0.00360612,-0.137326,44.4,1.9027117763827295,9.551088076086012,1.278785972483287e-10,0.2974064993060134,255.88371634375977,16.11084269694338,-0.4196,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350DEG14C27(II),Trina Solar,Mono-c-Si,1,350.0,325.3,1.96,,,72.0,9.54,47.6,8.93,39.2,0.00396864,-0.1332324,44.3,1.7965841703313692,9.55393473591356,2.9092158306988893e-11,0.32308098146866626,221.18772911276292,6.213323896347705,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350PE15H,Trina Solar,Multi-c-Si,0,350.0,325.0,1.99,,,48.0,9.71,46.7,9.23,37.9,0.0043695,-0.1381386,44.3,1.7499743639564824,9.711071188568203,2.4947714904316452e-11,0.37913195111636067,3436.7168981341947,-1.0198497212450865,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350PE15HT0,Trina Solar,Multi-c-Si,0,350.0,325.0,1.99,,,48.0,9.71,46.7,9.23,37.9,0.0043695,-0.1393995,44.3,1.7506923868384525,9.711053196885336,2.5222797270936987e-11,0.37896499820015994,3493.8772626447067,-1.833379137162456,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-350PEG15H20(II),Trina Solar,Multi-c-Si,0,350.0,322.7,2.03,,,48.0,9.71,46.7,9.23,37.9,0.00406849,-0.1393995,45.6,1.757637571884747,9.710879807274805,2.803229991461218e-11,0.37735144118803743,4164.643109056339,-0.9521190461158493,-0.3734,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD14A(II),Trina Solar,Mono-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD14A05(II),Trina Solar,Mono-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD14A08(II),Trina Solar,Mono-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD14A10(II),Trina Solar,Mono-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD14A15(II),Trina Solar,Mono-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD14A18(II),Trina Solar,Mono-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD151M(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.9227,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD151M08(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.9227,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD151MT0(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.9227,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DD151MT8(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.9227,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE06X05(II),Trina Solar,Mono-c-Si,0,355.0,329.8,1.82,,,66.0,10.24,44.6,9.66,36.8,0.00374784,-0.1175656,46.5,1.6161697491733023,10.250202554980266,1.0454735500225724e-11,0.2882806725663327,289.3387105986071,3.294468394744082,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE06XC05(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.82,,,66.0,10.24,44.6,9.66,36.8,0.0024678400000000002,-0.11725340000000001,45.4,1.6231163097787429,10.250000019341707,1.1767716743367909e-11,0.28668922135886843,293.5691965097049,4.740519838287689,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE06XC07(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.82,,,66.0,10.24,44.6,9.66,36.8,0.0024678400000000002,-0.11725340000000001,45.4,1.6231163097787429,10.250000019341707,1.1767716743367909e-11,0.28668922135886843,293.5691965097049,4.740519838287689,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE14A(II),Trina Solar,Multi-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE14A08(II),Trina Solar,Multi-c-Si,0,355.0,320.2,1.9403519999999999,1.956,0.992,72.0,9.69,47.0,9.17,38.7,0.00500973,-0.163278,46.3,2.0029868880981083,9.690021270783339,5.965323942490224e-10,0.2707997266406609,123373.36831765222,-2.5460958962754723,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE14H(II),Trina Solar,Mono-c-Si,0,355.0,330.7,1.96,,,48.0,9.68,46.9,9.21,38.6,0.00436568,-0.12864669999999997,44.4,1.7361288867613744,9.681805700887377,1.7891729113330144e-11,0.3223023380833192,1727.7982638458507,3.980932873469246,-0.3529,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE151M(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.93,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE151M08(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.93,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE151MT0(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.93,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DE151MT8(II),Trina Solar,Mono-c-Si,0,355.0,330.0,1.93,,,60.0,10.7,41.6,10.2,34.8,0.0035738,-0.11360960000000002,44.88,1.5360502523130062,10.700004736962265,1.8519224194137773e-11,0.19857927857355842,447805.23111642146,4.031415569887628,-0.3567,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DEG14(II),Trina Solar,Mono-c-Si,0,355.0,323.1,1.962176,1.978,0.992,72.0,9.69,47.0,9.17,38.7,0.00529074,-0.141658,46.2,1.908829569447133,9.692633331073077,1.9544530568849774e-10,0.28172527577913764,1036.6787926342383,14.574907369448821,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DEG1407(II),Trina Solar,Mono-c-Si,0,355.0,323.1,1.962176,1.978,0.992,72.0,9.69,47.0,9.17,38.7,0.00529074,-0.141658,46.2,1.908829569447133,9.692633331073077,1.9544530568849774e-10,0.28172527577913764,1036.6787926342383,14.574907369448821,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DEG1440(II),Trina Solar,Mono-c-Si,0,355.0,323.1,1.962176,1.978,0.992,72.0,9.69,47.0,9.17,38.7,0.00529074,-0.141658,46.2,1.908829569447133,9.692633331073077,1.9544530568849774e-10,0.28172527577913764,1036.6787926342383,14.574907369448821,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DEG1447(II),Trina Solar,Mono-c-Si,0,355.0,323.1,1.962176,1.978,0.992,72.0,9.69,47.0,9.17,38.7,0.00529074,-0.141658,46.2,1.908829569447133,9.692633331073077,1.9544530568849774e-10,0.28172527577913764,1036.6787926342383,14.574907369448821,-0.4246,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DEG14C07(II),Trina Solar,Mono-c-Si,1,355.0,326.1,1.962,,,72.0,9.61,47.8,9.01,39.4,0.00363258,-0.137903,44.4,1.9100506056146842,9.619926350484839,1.2794712691920757e-10,0.2921213719284191,282.81154382448096,16.04091055177261,-0.4196,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355DEG14C27(II),Trina Solar,Mono-c-Si,1,355.0,330.0,1.96,,,72.0,9.61,47.8,9.01,39.4,0.0039977599999999995,-0.13379219999999997,44.3,1.8035423221909352,9.622670944719918,2.910504421638098e-11,0.31766711926281116,240.9276588830854,6.148092922379827,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355PE15H,Trina Solar,Multi-c-Si,0,355.0,329.8,1.99,,,48.0,9.81,47.0,9.32,38.1,0.0044145,-0.139026,44.3,1.7606223313662002,9.81153689393724,2.4965952481042764e-11,0.38309215933459606,2445.2790195819925,-1.0942936627878594,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-355PE15HT0,Trina Solar,Multi-c-Si,0,355.0,327.0,1.99,,,48.0,9.81,47.0,9.32,38.1,0.0050227200000000005,-0.14194,46.0,1.7879530372208685,9.81000935484588,3.7613698545582834e-11,0.37678938359837144,395132.8015069701,0.038700791616979924,-0.3751,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DD14A(II),Trina Solar,Mono-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DD14A05(II),Trina Solar,Mono-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DD14A08(II),Trina Solar,Mono-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DD14A10(II),Trina Solar,Mono-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DD14A15(II),Trina Solar,Mono-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DD14A18(II),Trina Solar,Mono-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DE06X05(II),Trina Solar,Mono-c-Si,0,360.0,334.6,1.82,,,66.0,10.3,44.8,9.74,37.0,0.0037698000000000002,-0.11809279999999998,46.5,1.6223487078784606,10.308171793259106,1.0354806167998628e-11,0.28384674450110264,357.7698783509222,3.15472631020487,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DE06XC05(II),Trina Solar,Mono-c-Si,0,360.0,334.8,1.82,,,66.0,10.3,44.8,9.74,37.0,0.0024823000000000002,-0.1177792,45.4,1.6293143514583488,10.307981230247087,1.1654682526674948e-11,0.2822637622412129,364.2692376343406,4.598522447288387,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DE06XC07(II),Trina Solar,Mono-c-Si,0,360.0,334.8,1.82,,,66.0,10.3,44.8,9.74,37.0,0.0024823000000000002,-0.1177792,45.4,1.6293143514583488,10.307981230247087,1.1654682526674948e-11,0.2822637622412129,364.2692376343406,4.598522447288387,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DE14A(II),Trina Solar,Multi-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DE14A08(II),Trina Solar,Multi-c-Si,0,360.0,324.9,1.9403519999999999,1.956,0.992,72.0,9.79,47.2,9.26,38.9,0.00506143,-0.1639728,46.3,2.003235772575495,9.791512084224532,5.71205047328379e-10,0.25629613764687836,1659.3927214359653,8.221121919368766,-0.4625,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DE14H(II),Trina Solar,Mono-c-Si,0,360.0,335.5,1.96,,,48.0,9.73,47.2,9.28,38.8,0.004388230000000001,-0.1294696,44.4,1.7446307715264844,9.730004219403352,1.7318822776331914e-11,0.3285042240578082,757550.9040804475,3.6542801552824358,-0.3529,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DEG14(II),Trina Solar,Mono-c-Si,0,360.0,335.3,1.96,,,72.0,9.57,46.9,9.18,39.2,0.00435435,-0.1281308,43.3,1.800961247435925,9.570002018678748,4.6899218054828344e-11,0.21092771607679772,999998.2576960463,12.948467847586858,-0.3776,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-360DEG1440(II),Trina Solar,Mono-c-Si,0,360.0,330.7,1.962,,,72.0,9.57,46.9,9.18,39.2,0.0030241200000000004,-0.1341809,45.1,1.842441071164896,9.570001880355328,8.429225795478974e-11,0.19646699410201957,999982.9430202584,13.209759655168115,-0.4073,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-360DEG14C07(II),Trina Solar,Mono-c-Si,1,360.0,330.9,1.962,,,72.0,9.68,48.0,9.09,39.6,0.00365904,-0.13848,44.4,1.917403002044126,9.688798510088233,1.2803607478602173e-10,0.2869242977521388,315.6701879909238,15.973074684812353,-0.4196,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360DEG14C27(II),Trina Solar,Mono-c-Si,1,360.0,334.8,1.96,,,72.0,9.68,48.0,9.09,39.6,0.00402688,-0.134352,44.3,1.8105126676382601,9.691441577583982,2.91226450383566e-11,0.3123439390479612,264.25458735696145,6.084812706376652,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-360PE15HT0,Trina Solar,Multi-c-Si,0,360.0,334.5,1.99,,,48.0,9.89,47.2,9.4,38.3,0.0044505,-0.140892,44.3,1.7675357991328482,9.890009186947774,2.4995369163800925e-11,0.377145845499988,406013.03937124874,-2.054952064505321,-0.3669,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DD14A(II),Trina Solar,Mono-c-Si,0,365.0,334.8,1.92,,,72.0,9.77,48.0,9.3,39.3,0.00395685,-0.15364799999999998,44.6,1.9330568582146173,9.770002978128826,1.606448143315112e-10,0.3047632199532443,999999.9781533517,6.227915562133503,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-365DD14A10(II),Trina Solar,Mono-c-Si,0,365.0,334.8,1.92,,,72.0,9.77,48.0,9.3,39.3,0.00395685,-0.15364799999999998,44.6,1.9330568582146173,9.770002978128826,1.606448143315112e-10,0.3047632199532443,999999.9781533517,6.227915562133503,-0.429,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-365DE06X05(II),Trina Solar,Mono-c-Si,0,365.0,339.3,1.82,,,66.0,10.35,45.0,9.82,37.2,0.0037881,-0.11862,46.5,1.6278091974414604,10.355397359518182,1.0133825466582945e-11,0.27978677865990426,536.5203440401964,2.919173328810792,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DE06XC05(II),Trina Solar,Mono-c-Si,0,365.0,339.6,1.82,,,66.0,10.35,45.0,9.82,37.2,0.0024943499999999998,-0.11830500000000001,45.4,1.6347889700656368,10.355223177485309,1.1405659794247477e-11,0.2782135856769827,551.2948105178392,4.359714560863818,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DE06XC07(II),Trina Solar,Mono-c-Si,0,365.0,339.6,1.82,,,66.0,10.35,45.0,9.82,37.2,0.0024943499999999998,-0.11830500000000001,45.4,1.6347889700656368,10.355223177485309,1.1405659794247477e-11,0.2782135856769827,551.2948105178392,4.359714560863818,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DE14A(II),Trina Solar,Mono-c-Si,0,365.0,339.3,1.92,,,72.0,9.77,48.0,9.3,39.3,0.00314594,-0.13094399999999998,44.3,1.7862157087022967,9.770845851832599,2.0837413392549754e-11,0.34889741025864546,4029.935324889397,5.939561580895012,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DE14H(II),Trina Solar,Mono-c-Si,0,365.0,340.3,1.96,,,48.0,9.83,47.4,9.37,39.0,0.00443333,-0.1300182,44.4,1.7523048695314807,9.83000721639145,1.7572977102916174e-11,0.3223615360736716,439118.8144825117,3.69079766553029,-0.3529,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DEG14(II),Trina Solar,Mono-c-Si,0,365.0,335.4,1.962,,,72.0,9.61,47.1,9.25,39.5,0.00303676,-0.13475310000000001,45.1,1.8565044837553526,9.61012726968312,9.212766889441678e-11,0.16067873911310965,12132.693954217642,13.98419464740083,-0.4073,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-365DEG1440(II),Trina Solar,Mono-c-Si,0,365.0,335.4,1.962,,,72.0,9.61,47.1,9.25,39.5,0.00303676,-0.13475310000000001,45.1,1.8565044837553526,9.61012726968312,9.212766889441678e-11,0.16067873911310965,12132.693954217642,13.98419464740083,-0.4073,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-365DEG14C07(II),Trina Solar,Mono-c-Si,1,365.0,335.6,1.962,,,72.0,9.75,48.2,9.17,39.8,0.0036855,-0.13905700000000001,44.4,1.9247685459151727,9.757703868383429,1.2814464681897704e-10,0.2818131330503307,356.66214104807307,15.907262600239127,-0.4196,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DEG14C27(II),Trina Solar,Mono-c-Si,1,365.0,339.6,1.96,,,72.0,9.75,48.2,9.17,39.8,0.004056,-0.1349118,44.3,1.81749483006904,9.760245928739199,2.914477658613762e-11,0.3071092166254506,292.24436052832095,6.023415877876006,-0.3652,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DEG14H(II),Trina Solar,Mono-c-Si,0,365.0,340.6,1.98,,,48.0,9.83,47.4,9.37,39.0,0.00322424,-0.127506,43.6,1.7471452245123162,9.830416060680514,1.6214405039357872e-11,0.3235770256182296,7644.9450748174695,5.224351363942215,-0.3618,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DEG14HC20(II),Trina Solar,Mono-c-Si,1,365.0,341.8,1.98,,,48.0,9.69,48.6,9.18,39.8,0.00345933,-0.133893,43.2,1.7803936163551166,9.695745902474286,1.3425355606574276e-11,0.3626943556527514,611.6547179199256,1.2771844171455384,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365DEG14HC27(II),Trina Solar,Mono-c-Si,1,365.0,340.5,1.98,,,48.0,9.69,48.6,9.18,39.8,0.00264537,-0.1396764,43.0,1.8146794847930545,9.694922017566928,2.2507010896416187e-11,0.3545571686711054,698.0184459570293,1.3139995016836366,-0.3756,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365NE09RC05,Trina Solar,Mono-c-Si,0,365.0,342.5,1.98,,,72.0,10.06,47.1,9.44,38.7,0.004637660000000001,-0.11888040000000001,44.72,1.6740318751655614,10.076134976776089,5.947976230962937e-12,0.3373429168525687,210.33000642784717,3.097084522699278,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-365PE15HT0,Trina Solar,Multi-c-Si,0,365.0,336.4,1.99,,,48.0,9.98,47.3,9.48,38.5,0.0051097600000000005,-0.142846,46.0,1.804723663604026,9.98128184450271,4.1306075574572236e-11,0.3532719741654498,2750.4545069847536,0.6637027992575596,-0.3751,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DE06X05(II),Trina Solar,Mono-c-Si,0,370.0,344.1,1.82,,,66.0,10.4,45.2,9.9,37.4,0.0038064000000000006,-0.11914720000000001,46.5,1.6286284400035278,10.400006179139602,9.201842947652751e-12,0.27673157867894715,465765.3666546697,2.046122291239895,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DE06XC05(II),Trina Solar,Mono-c-Si,0,370.0,344.3,1.82,,,66.0,10.4,45.2,9.9,37.4,0.0025064,-0.11883080000000001,45.4,1.6402887949226146,10.402547616179683,1.1168079430835858e-11,0.2742193406790006,1119.431264556847,4.126319688680229,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DE06XC07(II),Trina Solar,Mono-c-Si,0,370.0,344.3,1.82,,,66.0,10.4,45.2,9.9,37.4,0.0025064,-0.11883080000000001,45.4,1.6402887949226146,10.402547616179683,1.1168079430835858e-11,0.2742193406790006,1119.431264556847,4.126319688680229,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DE14A(II),Trina Solar,Mono-c-Si,0,370.0,344.0,1.92,,,72.0,9.83,48.3,9.33,39.7,0.00316526,-0.1317624,44.3,1.8034060807494938,9.833485596716772,2.2848062397587195e-11,0.3298057335734619,930.1103568568643,6.692217801627674,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DE14H(II),Trina Solar,Mono-c-Si,0,370.0,345.1,1.96,,,48.0,9.88,47.6,9.44,39.2,0.004455880000000001,-0.1305668,44.4,1.7620860705710117,9.880004244928653,1.8321791226637217e-11,0.3170967492719334,738053.0132072845,3.9993072316686487,-0.3529,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DEG14(II),Trina Solar,Mono-c-Si,0,370.0,344.8,1.96,,,72.0,9.66,47.3,9.32,39.7,0.0043953,-0.1292236,43.3,1.8248397295518999,9.660126169108477,5.3438920923232504e-11,0.1583365005241581,12122.86770336357,14.059210312397465,-0.3776,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-370DEG1440(II),Trina Solar,Mono-c-Si,0,370.0,344.8,1.96,,,72.0,9.66,47.3,9.32,39.7,0.0043953,-0.1292236,43.3,1.8248397295518999,9.660126169108477,5.3438920923232504e-11,0.1583365005241581,12122.86770336357,14.059210312397465,-0.3776,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-370DEG14H(II),Trina Solar,Mono-c-Si,0,370.0,345.4,1.98,,,48.0,9.88,47.6,9.44,39.2,0.003240640000000001,-0.12804400000000002,43.6,1.7562027829869027,9.880004260404478,1.6736567487256253e-11,0.31845259272394033,738515.1768969167,5.44897415248864,-0.3618,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DEG14HC20(II),Trina Solar,Mono-c-Si,1,370.0,346.5,1.98,,,48.0,9.79,48.8,9.26,40.0,0.0034950299999999997,-0.134444,43.2,1.789878979171106,9.797188547167117,1.3990452789035732e-11,0.35595115004127503,484.7657973750258,1.5387208292263255,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370DEG14HC27(II),Trina Solar,Mono-c-Si,1,370.0,345.3,1.98,,,48.0,9.79,48.8,9.26,40.0,0.00267267,-0.1402512,43.0,1.8243881714963988,9.796334056316114,2.3453660406224027e-11,0.3478233288831658,537.6002815122487,1.574115604101043,-0.3756,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370NE09RC05,Trina Solar,Mono-c-Si,0,370.0,347.3,1.98,,,72.0,10.09,47.1,9.47,39.1,0.00465149,-0.11888040000000001,44.72,1.6823989363816203,10.104197426936137,6.85646115089597e-12,0.2879399647977409,204.6366754304066,4.280894521214123,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-370PE15HT0,Trina Solar,Multi-c-Si,0,370.0,341.1,1.99,,,48.0,10.06,47.7,9.56,38.7,0.005150720000000001,-0.14405400000000002,46.0,1.8154603905124769,10.060008686600371,3.9065941305401606e-11,0.3688819617254005,427217.1581148492,0.14155112969282607,-0.3751,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DE06X05(II),Trina Solar,Mono-c-Si,0,375.0,348.9,1.82,,,66.0,10.45,45.3,9.98,37.6,0.0038247,-0.11941079999999998,46.5,1.636963057522058,10.45023429880805,1.0014938493455614e-11,0.2617341291632538,11673.633356328568,2.7126268611632436,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DE06XC05(II),Trina Solar,Mono-c-Si,0,375.0,349.1,1.82,,,66.0,10.45,45.3,9.98,37.6,0.0025184499999999998,-0.1190937,45.4,1.643961631703576,10.45009726724262,1.1269384210637688e-11,0.2601795879316654,27952.450878918564,4.148071599523228,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DE06XC07(II),Trina Solar,Mono-c-Si,0,375.0,349.1,1.82,,,66.0,10.45,45.3,9.98,37.6,0.0025184499999999998,-0.1190937,45.4,1.643961631703576,10.45009726724262,1.1269384210637688e-11,0.2601795879316654,27952.450878918564,4.148071599523228,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DE0905,Trina Solar,Mono-c-Si,0,375.0,352.7,1.91,,,60.0,11.93,40.2,11.3,33.2,0.0044141,-0.095274,44.3,1.4113203986803176,11.939402846481352,5.029007894867826e-12,0.22857274917438208,290.0050438630425,6.929624317182011,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DE14A(II),Trina Solar,Mono-c-Si,0,375.0,348.8,1.92,,,72.0,9.88,48.5,9.37,40.0,0.0031813600000000003,-0.13230799999999998,44.3,1.8146971877730422,9.884168903404705,2.42663779062633e-11,0.3127738574658412,741.2514737162273,7.173112371164863,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DE14H(II),Trina Solar,Mono-c-Si,0,375.0,349.8,1.96,,,48.0,9.93,47.8,9.52,39.4,0.00447843,-0.1311154,44.4,1.7728177162851806,9.930002868115306,1.93724146359327e-11,0.28882215801370625,999988.5163702521,4.427524689864921,-0.3529,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-375DEG14(II),Trina Solar,Mono-c-Si,0,375.0,349.6,1.96,,,72.0,9.71,47.5,9.39,40.0,0.00441805,-0.12977,43.3,1.8371074047445868,9.710103018096522,5.7278283801321905e-11,0.12912434778479767,12170.658489200767,14.651305566453264,-0.3776,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-375DEG1440(II),Trina Solar,Mono-c-Si,0,375.0,349.6,1.96,,,72.0,9.71,47.5,9.39,40.0,0.00441805,-0.12977,43.3,1.8371074047445868,9.710103018096522,5.7278283801321905e-11,0.12912434778479767,12170.658489200767,14.651305566453264,-0.3776,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-375DEG14H(II),Trina Solar,Mono-c-Si,0,375.0,350.2,1.98,,,48.0,9.93,47.8,9.52,39.4,0.00325704,-0.128582,43.6,1.7667597990340256,9.930002888226728,1.7661719370782027e-11,0.29085031885566304,999996.4897756331,5.865593474560587,-0.3618,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-375DEG14HC20(II),Trina Solar,Mono-c-Si,1,375.0,351.3,1.98,,,48.0,9.89,49.0,9.34,40.2,0.00353073,-0.134995,43.2,1.7993612611921697,9.898590999407377,1.457258541283806e-11,0.3493247884893303,402.14438708849735,1.7977693171112041,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375DEG14HC27(II),Trina Solar,Mono-c-Si,1,375.0,350.1,1.98,,,48.0,9.89,49.0,9.34,40.2,0.0026999700000000003,-0.14082599999999998,43.0,1.8340940980015166,9.897705686914172,2.442893977755821e-11,0.34120608314563816,437.926977725833,1.831806827856614,-0.3756,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-375NE09RC05,Trina Solar,Mono-c-Si,0,375.0,352.1,1.98,,,72.0,10.12,47.1,9.51,39.5,0.00466532,-0.11888040000000001,44.72,1.6898725219597135,10.131452095505702,7.787247404060184e-12,0.2390442195225943,211.23882482195984,5.3441835847275705,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE06X05(II),Trina Solar,Mono-c-Si,0,380.0,353.7,1.82,,,66.0,10.51,45.5,10.07,37.8,0.00384666,-0.119938,46.5,1.6444458126546582,10.540298112191696,1.0148508287159423e-11,0.25683282043542804,999999.9851582289,2.75154278199722,-0.339,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE06XC05(II),Trina Solar,Mono-c-Si,0,380.0,353.9,1.82,,,66.0,10.51,45.5,10.07,37.8,0.0025329099999999998,-0.11961950000000002,45.4,1.6540316911158675,10.510004002817247,1.1879335395670339e-11,0.2552246502965657,670138.8644268126,4.544648717584469,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE06XC07(II),Trina Solar,Mono-c-Si,0,380.0,353.9,1.82,,,66.0,10.51,45.5,10.07,37.8,0.0025329099999999998,-0.11961950000000002,45.4,1.6540316911158675,10.510004002817247,1.1879335395670339e-11,0.2552246502965657,670138.8644268126,4.544648717584469,-0.3541,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE09,Trina Solar,Mono-c-Si,0,380.0,354.0,1.91,,,60.0,12.0,40.4,11.38,33.4,0.00396,-0.107464,44.8,1.4876885575065273,12.005887934457794,1.915097691591039e-11,0.21134140583619002,430.7277747923285,6.156316905477108,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE0905,Trina Solar,Mono-c-Si,0,380.0,357.5,1.91,,,60.0,12.0,40.4,11.38,33.4,0.0044399999999999995,-0.09574799999999999,44.3,1.4182809965062355,12.008192418236678,5.058939174848006e-12,0.22488504556678282,329.4046371101201,6.925056021697714,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE0908,Trina Solar,Mono-c-Si,0,380.0,354.0,1.91,,,60.0,12.0,40.4,11.38,33.4,0.00396,-0.107464,44.8,1.4876885575065273,12.005887934457794,1.915097691591039e-11,0.21134140583619002,430.7277747923285,6.156316905477108,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE09C05,Trina Solar,Mono-c-Si,0,380.0,354.1,1.91,,,60.0,12.0,40.4,11.38,33.4,0.00384,-0.10346439999999998,45.58,1.4497471532417299,12.00000737547106,9.478163688300494e-12,0.21855746985239305,355598.5492044876,4.1469105233501224,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE09C07,Trina Solar,Mono-c-Si,0,380.0,354.1,1.91,,,60.0,12.0,40.4,11.38,33.4,0.00384,-0.10346439999999998,45.58,1.4497471532417299,12.00000737547106,9.478163688300494e-12,0.21855746985239305,355598.5492044876,4.1469105233501224,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE14A(II),Trina Solar,Mono-c-Si,0,380.0,353.6,1.92,,,72.0,9.94,48.8,9.43,40.3,0.00320068,-0.13312639999999998,44.3,1.8268499359514767,9.943935379008261,2.475368089386799e-11,0.30640153426783834,773.9105424573983,7.291807516495373,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DE14H(II),Trina Solar,Mono-c-Si,0,380.0,354.6,1.96,,,48.0,9.99,48.0,9.6,39.6,0.00450549,-0.131664,44.4,1.7827196452082714,9.990002840955144,2.0235683071017e-11,0.27272042670527336,959024.353564312,4.7458551005739,-0.3529,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-380DEG14H(II),Trina Solar,Mono-c-Si,0,380.0,355.0,1.98,,,48.0,9.99,48.0,9.6,39.6,0.0032767200000000003,-0.12912,43.6,1.776588545016348,9.990002861173862,1.8440095979332198e-11,0.27479178561266515,959477.9533117857,6.183664485043146,-0.3618,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-380DEG14HC20(II),Trina Solar,Mono-c-Si,1,380.0,356.1,1.98,,,48.0,9.99,49.2,9.43,40.3,0.00356643,-0.13554600000000003,43.2,1.8056507615772257,9.999188441354683,1.44819502289082e-11,0.3550593609777969,386.0331473284555,1.6647866838750014,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DEG14HC27(II),Trina Solar,Mono-c-Si,1,380.0,354.8,1.98,,,48.0,9.99,49.2,9.43,40.3,0.0027272700000000004,-0.14140080000000002,43.0,1.8404884711710106,9.998268953335247,2.427851799253161e-11,0.3470026974134733,419.22559804670027,1.6999800225642674,-0.3756,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DEG15HC(II),Trina Solar,Mono-c-Si,1,380.0,355.1,2.009928,,,48.0,9.99,49.2,9.43,40.3,0.00405594,-0.13274160000000002,43.8,1.8174312561684662,9.998873517194411,1.7284942499849596e-11,0.35232845351301073,396.65909404086625,5.254591967135292,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380DEG15HC20(II),Trina Solar,Mono-c-Si,1,380.0,355.1,2.009928,,,48.0,9.99,49.2,9.43,40.3,0.00405594,-0.13274160000000002,43.8,1.8174312561684662,9.998873517194411,1.7284942499849596e-11,0.35232845351301073,396.65909404086625,5.254591967135292,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-380NE09RC05,Trina Solar,Mono-c-Si,0,380.0,356.9,1.98,,,72.0,10.15,47.5,9.54,39.8,0.004679150000000001,-0.11989000000000001,44.72,1.7033224541753815,10.161534819296817,7.698311100192264e-12,0.24463285211149674,215.26331626449203,5.218789138881877,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DE09,Trina Solar,Mono-c-Si,0,385.0,358.8,1.91,,,60.0,12.07,40.6,11.46,33.6,0.0039831,-0.10799600000000001,44.8,1.4949872023403892,12.074800112144802,1.9264435273036385e-11,0.20772781960211997,522.3367185464623,6.152123758526714,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DE0905,Trina Solar,Mono-c-Si,0,385.0,362.3,1.91,,,60.0,12.07,40.6,11.46,33.6,0.0044659,-0.096222,44.3,1.4168403171130834,12.07000792710107,4.3337093420920065e-12,0.222741462269822,339152.70646194316,5.486101651663713,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DE0908,Trina Solar,Mono-c-Si,0,385.0,358.8,1.91,,,60.0,12.07,40.6,11.46,33.6,0.0039831,-0.10799600000000001,44.8,1.4949872023403892,12.074800112144802,1.9264435273036385e-11,0.20772781960211997,522.3367185464623,6.152123758526714,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DE09C05,Trina Solar,Mono-c-Si,0,385.0,358.9,1.91,,,60.0,12.07,40.6,11.46,33.6,0.0038624,-0.1039766,45.58,1.458268413504108,12.070007895003181,9.781522661465986e-12,0.21468358087304504,328213.4953054764,4.364836381862585,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DE09C07,Trina Solar,Mono-c-Si,0,385.0,358.9,1.91,,,60.0,12.07,40.6,11.46,33.6,0.0038624,-0.1039766,45.58,1.458268413504108,12.070007895003181,9.781522661465986e-12,0.21468358087304504,328213.4953054764,4.364836381862585,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DE14H(II),Trina Solar,Mono-c-Si,0,385.0,359.4,1.96,,,48.0,10.03,48.5,9.61,40.1,0.00452353,-0.1330355,44.4,1.8006793127423917,10.030002803619203,2.013214126800561e-11,0.27951458499522264,999995.5125216704,4.668455404535537,-0.3529,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-385DE15H(II),Trina Solar,Mono-c-Si,0,385.0,360.6,1.985912,,,48.0,10.03,48.5,9.61,40.1,0.00405212,-0.1309985,43.8,1.7745508496328075,10.030002890124587,1.3541210166813803e-11,0.28814206678474513,999998.564148012,3.004135209096531,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-385DEG14H(II),Trina Solar,Mono-c-Si,0,385.0,359.7,1.98,,,48.0,10.03,48.5,9.61,40.1,0.0032898400000000005,-0.130465,43.6,1.794511276835041,10.030002824033568,1.835202599190649e-11,0.2815512379536308,999998.4287637713,6.108289018711966,-0.3618,N,2025.7.3,6/23/2025,2.0,bootstrapping +Trina Solar TSM-385DEG14HC20(II),Trina Solar,Mono-c-Si,1,385.0,360.9,1.98,,,48.0,10.09,49.4,9.53,40.4,0.0036021300000000003,-0.13609700000000002,43.2,1.8110342306763245,10.098823243716511,1.4214725457788315e-11,0.36069344088856076,412.4783326137531,1.4264775672820535,-0.3526,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DEG15H(II),Trina Solar,Mono-c-Si,0,385.0,360.9,2.009928,,,48.0,10.03,48.5,9.61,40.1,0.00446335,-0.12823400000000001,43.6,1.7750408566587894,10.030002888502112,1.3643762152436643e-11,0.28798026902338014,999998.5523771347,5.246968197485206,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-385DEG15H20(II),Trina Solar,Mono-c-Si,0,385.0,360.9,2.009928,,,48.0,10.03,48.5,9.61,40.1,0.00446335,-0.12823400000000001,43.6,1.7750408566587894,10.030002888502112,1.3643762152436643e-11,0.28798026902338014,999998.5523771347,5.246968197485206,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-385DEG15HC(II),Trina Solar,Mono-c-Si,1,385.0,359.9,2.009928,,,48.0,10.09,49.4,9.53,40.4,0.00409654,-0.1332812,43.8,1.8228469259969011,10.09850357735571,1.6968520219920292e-11,0.3579873968274731,424.77333103120867,5.009231667599682,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DEG15HC20(II),Trina Solar,Mono-c-Si,1,385.0,359.9,2.009928,,,48.0,10.09,49.4,9.53,40.4,0.00409654,-0.1332812,43.8,1.8228469259969011,10.09850357735571,1.6968520219920292e-11,0.3579873968274731,424.77333103120867,5.009231667599682,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DEG15MC(II),Trina Solar,Mono-c-Si,1,385.0,360.1,2.01,,,48.0,10.21,48.3,9.65,39.9,0.00410442,-0.1296372,44.0,1.7748027644058173,10.217871882256107,1.5313272924197475e-11,0.30183875839776214,391.4912868894465,4.593633813048999,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385DEG15MC20(II),Trina Solar,Mono-c-Si,1,385.0,360.1,2.01,,,48.0,10.21,48.3,9.65,39.9,0.00410442,-0.1296372,44.0,1.7748027644058173,10.217871882256107,1.5313272924197475e-11,0.30183875839776214,391.4912868894465,4.593633813048999,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-385NE09RC05,Trina Solar,Mono-c-Si,0,385.0,361.7,1.98,,,72.0,10.19,48.0,9.57,40.2,0.00469759,-0.121152,44.72,1.7215012303770045,10.202180947005969,7.753012949656825e-12,0.24841191329338297,207.80957347717901,5.249149751235822,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE09,Trina Solar,Mono-c-Si,0,390.0,363.6,1.91,,,60.0,12.14,40.8,11.54,33.8,0.0040062000000000006,-0.108528,44.8,1.5022878546246068,12.143748192810186,1.9378517656850646e-11,0.2041643001451196,661.2665844986165,6.1482434650773685,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE0905,Trina Solar,Mono-c-Si,0,390.0,367.1,1.91,,,60.0,12.14,40.8,11.54,33.8,0.0044918,-0.09669599999999999,44.3,1.4322061983333665,12.145882057195115,5.1191458721834335e-12,0.21766326852902212,449.23604127207795,6.9166313707686795,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE0908,Trina Solar,Mono-c-Si,0,390.0,363.6,1.91,,,60.0,12.14,40.8,11.54,33.8,0.0040062000000000006,-0.108528,44.8,1.5022878546246068,12.143748192810186,1.9378517656850646e-11,0.2041643001451196,661.2665844986165,6.1482434650773685,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE09C05,Trina Solar,Mono-c-Si,0,390.0,363.7,1.91,,,60.0,12.14,40.8,11.54,33.8,0.0038848000000000003,-0.10448879999999999,45.58,1.4730918134567943,12.144607195460656,1.1301795711328778e-11,0.20975876571130056,552.7161732481808,5.571102022413709,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE09C07,Trina Solar,Mono-c-Si,0,390.0,363.7,1.91,,,60.0,12.14,40.8,11.54,33.8,0.0038848000000000003,-0.10448879999999999,45.58,1.4730918134567943,12.144607195460656,1.1301795711328778e-11,0.20975876571130056,552.7161732481808,5.571102022413709,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE15H(II),Trina Solar,Mono-c-Si,0,390.0,365.4,1.985912,,,48.0,10.08,49.7,9.64,40.5,0.00407232,-0.13423970000000002,43.8,1.8059206008122985,10.08000370640554,1.1256886249444266e-11,0.3676910003574479,999998.968288964,1.4292363526945084,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-390DE15HT0(II),Trina Solar,Mono-c-Si,0,390.0,365.4,1.99,,,48.0,10.08,49.7,9.64,40.5,0.00407232,-0.13423970000000002,43.8,1.8059206008122985,10.08000370640554,1.1256886249444266e-11,0.3676910003574479,999998.968288964,1.4292363526945084,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-390DE15M(II),Trina Solar,Mono-c-Si,0,390.0,365.7,1.99,,,48.0,10.3,48.5,9.75,40.0,0.004346600000000001,-0.1255665,44.1,1.755514426662663,10.307354018120536,1.0235674790112562e-11,0.3136174427330818,439.25098239084616,4.856471569609759,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DE15MT0(II),Trina Solar,Mono-c-Si,0,390.0,365.7,1.99,,,48.0,10.3,48.5,9.75,40.0,0.004346600000000001,-0.1255665,44.1,1.755514426662663,10.307354018120536,1.0235674790112562e-11,0.3136174427330818,439.25098239084616,4.856471569609759,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DEG15H(II),Trina Solar,Mono-c-Si,0,390.0,365.7,2.009928,,,48.0,10.08,49.7,9.64,40.5,0.0044856,-0.13140680000000002,43.6,1.8064589993553961,10.08000370464299,1.1349597851854657e-11,0.3675160978527376,999998.9734956599,3.6419445059254123,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-390DEG15H20(II),Trina Solar,Mono-c-Si,0,390.0,365.7,2.009928,,,48.0,10.08,49.7,9.64,40.5,0.0044856,-0.13140680000000002,43.6,1.8064589993553961,10.08000370464299,1.1349597851854657e-11,0.3675160978527376,999998.9734956599,3.6419445059254123,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-390DEG15HC(II),Trina Solar,Mono-c-Si,1,390.0,364.6,2.009928,,,48.0,10.19,49.6,9.63,40.5,0.004137139999999999,-0.13382080000000002,43.8,1.8282721070757308,10.198102867118067,1.666125895930438e-11,0.3635259246301802,457.1627739186843,4.767001136442692,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DEG15HC20(II),Trina Solar,Mono-c-Si,1,390.0,364.6,2.009928,,,48.0,10.19,49.6,9.63,40.5,0.004137139999999999,-0.13382080000000002,43.8,1.8282721070757308,10.198102867118067,1.666125895930438e-11,0.3635259246301802,457.1627739186843,4.767001136442692,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DEG15M(II),Trina Solar,Mono-c-Si,0,390.0,367.8,2.01,,,48.0,10.3,48.5,9.75,40.0,0.0039861,-0.125906,42.3,1.7535679949932819,10.30740310705942,9.92603625712603e-12,0.31405909711688484,436.9528493709073,4.359156117322865,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DEG15M20(II),Trina Solar,Mono-c-Si,0,390.0,367.8,2.01,,,48.0,10.3,48.5,9.75,40.0,0.0039861,-0.125906,42.3,1.7535679949932819,10.30740310705942,9.92603625712603e-12,0.31405909711688484,436.9528493709073,4.359156117322865,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DEG15MC(II),Trina Solar,Mono-c-Si,1,390.0,364.9,2.01,,,48.0,10.25,48.5,9.71,40.2,0.0041205,-0.130174,44.0,1.7832314327881968,10.255924106986754,1.566549978217146e-11,0.2860732628590315,494.96927839449506,4.744811149243217,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390DEG15MC20(II),Trina Solar,Mono-c-Si,1,390.0,364.9,2.01,,,48.0,10.25,48.5,9.71,40.2,0.0041205,-0.130174,44.0,1.7832314327881968,10.255924106986754,1.566549978217146e-11,0.2860732628590315,494.96927839449506,4.744811149243217,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-390NE09RC05,Trina Solar,Mono-c-Si,0,390.0,366.5,1.98,,,72.0,10.22,48.4,9.6,40.6,0.004711420000000001,-0.12216160000000001,44.72,1.7370625938349094,10.231777763980475,7.929647038244562e-12,0.24202635471292813,210.01514566787063,5.417420233795335,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE09,Trina Solar,Mono-c-Si,0,395.0,368.4,1.91,,,60.0,12.21,41.0,11.62,34.0,0.0040293,-0.10906000000000002,44.8,1.5095883888761312,12.212731441496539,1.9492481239788263e-11,0.20065020982839465,896.939998981337,6.144343727477184,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE0905,Trina Solar,Mono-c-Si,0,395.0,372.0,1.91,,,60.0,12.21,41.0,11.62,34.0,0.0045177,-0.09717,44.3,1.4332643187561713,12.210007683975801,4.605442136530378e-12,0.21516268805725086,341899.13661054865,5.914014313971114,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE0908,Trina Solar,Mono-c-Si,0,395.0,368.4,1.91,,,60.0,12.21,41.0,11.62,34.0,0.0040293,-0.10906000000000002,44.8,1.5095883888761312,12.212731441496539,1.9492481239788263e-11,0.20065020982839465,896.939998981337,6.144343727477184,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE09C05,Trina Solar,Mono-c-Si,0,395.0,368.5,1.91,,,60.0,12.21,41.0,11.62,34.0,0.0039072,-0.10500100000000001,45.58,1.4802513819526293,12.213555193403842,1.1368185622130584e-11,0.20623571228801094,708.2984606080172,5.567045166033108,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE09C07,Trina Solar,Mono-c-Si,0,395.0,368.5,1.91,,,60.0,12.21,41.0,11.62,34.0,0.0039072,-0.10500100000000001,45.58,1.4802513819526293,12.213555193403842,1.1368185622130584e-11,0.20623571228801094,708.2984606080172,5.567045166033108,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE15H(II),Trina Solar,Mono-c-Si,0,395.0,370.2,1.985912,,,48.0,10.13,50.1,9.69,40.8,0.0040925200000000005,-0.1353201,43.8,1.8201408925893687,10.130003754142413,1.1259094082033594e-11,0.37058837031966574,999998.6990673763,1.390072066428652,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-395DE15HT0(II),Trina Solar,Mono-c-Si,0,395.0,370.2,1.99,,,48.0,10.13,50.1,9.69,40.8,0.0040925200000000005,-0.1353201,43.8,1.8201408925893687,10.130003754142413,1.1259094082033594e-11,0.37058837031966574,999998.6990673763,1.390072066428652,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-395DE15M(II),Trina Solar,Mono-c-Si,0,395.0,370.5,1.99,,,48.0,10.37,48.7,9.86,40.1,0.004376140000000001,-0.1260843,44.1,1.751720477700787,10.370007136801782,8.746814578796957e-12,0.3216790017805621,467413.0954092856,3.4279322783135364,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DE15MT0(II),Trina Solar,Mono-c-Si,0,395.0,370.5,1.99,,,48.0,10.37,48.7,9.86,40.1,0.004376140000000001,-0.1260843,44.1,1.751720477700787,10.370007136801782,8.746814578796957e-12,0.3216790017805621,467413.0954092856,3.4279322783135364,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DEG15H(II),Trina Solar,Mono-c-Si,0,395.0,370.5,2.009928,,,48.0,10.13,50.1,9.69,40.8,0.004507850000000001,-0.1324644,43.6,1.8206846368409366,10.130003752359974,1.135202973780768e-11,0.3704123649822335,999998.6986689719,3.6020444355507455,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-395DEG15H20(II),Trina Solar,Mono-c-Si,0,395.0,370.5,2.009928,,,48.0,10.13,50.1,9.69,40.8,0.004507850000000001,-0.1324644,43.6,1.8206846368409366,10.130003752359974,1.135202973780768e-11,0.3704123649822335,999998.6986689719,3.6020444355507455,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-395DEG15HC(II),Trina Solar,Mono-c-Si,1,395.0,369.4,2.009928,,,48.0,10.29,49.7,9.73,40.6,0.004177739999999999,-0.1340906,43.8,1.8318917817055231,10.297624954533134,1.6818609894561496e-11,0.35854231452890095,483.8586912482457,4.761664254681787,-0.3546,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-395DEG15HC20(II),Trina Solar,Mono-c-Si,1,395.0,369.4,2.009928,,,48.0,10.29,49.7,9.73,40.6,0.004177739999999999,-0.1340906,43.8,1.8318917817055231,10.297624954533134,1.6818609894561496e-11,0.35854231452890095,483.8586912482457,4.761664254681787,-0.3546,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-395DEG15M(II),Trina Solar,Mono-c-Si,0,395.0,372.6,2.01,,,48.0,10.37,48.7,9.86,40.1,0.00401319,-0.12642520000000002,42.3,1.755783536974601,10.373599245630285,9.28397899895958e-12,0.32089903178255275,924.561236921968,3.7153509508178826,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DEG15M20(II),Trina Solar,Mono-c-Si,0,395.0,372.6,2.01,,,48.0,10.37,48.7,9.86,40.1,0.00401319,-0.12642520000000002,42.3,1.755783536974601,10.373599245630285,9.28397899895958e-12,0.32089903178255275,924.561236921968,3.7153509508178826,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DEG15MC(II),Trina Solar,Mono-c-Si,1,395.0,369.7,2.01,,,48.0,10.29,48.7,9.76,40.5,0.00413658,-0.13071080000000002,44.0,1.7925197276809768,10.294900262945996,1.6213510002884697e-11,0.2704263538302045,567.86483778429,4.999856442070096,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395DEG15MC20(II),Trina Solar,Mono-c-Si,1,395.0,369.7,2.01,,,48.0,10.29,48.7,9.76,40.5,0.00413658,-0.13071080000000002,44.0,1.7925197276809768,10.294900262945996,1.6213510002884697e-11,0.2704263538302045,567.86483778429,4.999856442070096,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-395NE09RC05,Trina Solar,Mono-c-Si,0,395.0,371.3,1.98,,,72.0,10.26,48.8,9.65,41.0,0.00472986,-0.12317120000000001,44.72,1.7517020348417098,10.270725020231428,8.00761150888701e-12,0.23559513242625216,225.3800936073569,5.4629373079452,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE09,Trina Solar,Mono-c-Si,0,400.0,373.2,1.91,,,60.0,12.28,41.2,11.7,34.2,0.0040524,-0.10959200000000001,44.8,1.5142449876278752,12.280008050947993,1.874081244480304e-11,0.1976391577437079,301459.06671235216,5.7443961132657275,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE0905,Trina Solar,Mono-c-Si,0,400.0,376.8,1.91,,,60.0,12.28,41.2,11.7,34.2,0.004543599999999999,-0.09764400000000001,44.3,1.4414763619099538,12.280008067402816,4.745399853256252e-12,0.2114511846374818,321866.69386803306,6.1248623305962795,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE0908,Trina Solar,Mono-c-Si,0,400.0,373.2,1.91,,,60.0,12.28,41.2,11.7,34.2,0.0040524,-0.10959200000000001,44.8,1.5142449876278752,12.280008050947993,1.874081244480304e-11,0.1976391577437079,301459.06671235216,5.7443961132657275,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE09C05,Trina Solar,Mono-c-Si,0,400.0,373.2,1.91,,,60.0,12.28,41.2,11.7,34.2,0.0039296,-0.1055132,45.58,1.4838283932465597,12.280007633397407,1.072920396203486e-11,0.2033810652729399,327185.2273425562,5.005332355905096,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE09C07,Trina Solar,Mono-c-Si,0,400.0,373.2,1.91,,,60.0,12.28,41.2,11.7,34.2,0.0039296,-0.1055132,45.58,1.4838283932465597,12.280007633397407,1.072920396203486e-11,0.2033810652729399,327185.2273425562,5.005332355905096,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE15H(II),Trina Solar,Mono-c-Si,0,400.0,375.0,1.985912,,,48.0,10.18,50.4,9.74,41.1,0.00411272,-0.1361304,43.8,1.8322576808657638,10.18000370415145,1.1523558750916998e-11,0.3638576431291631,999998.615785327,1.540918618217058,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-400DE15HT0(II),Trina Solar,Mono-c-Si,0,400.0,375.0,1.99,,,48.0,10.18,50.4,9.74,41.1,0.00411272,-0.1361304,43.8,1.8322576808657638,10.18000370415145,1.1523558750916998e-11,0.3638576431291631,999998.615785327,1.540918618217058,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-400DE15M(II),Trina Solar,Mono-c-Si,0,400.0,375.3,1.99,,,48.0,10.45,49.0,9.92,40.3,0.0044099,-0.126861,44.1,1.7688557297742622,10.455024224968259,9.67582168976174e-12,0.32538046640411283,676.7662542217568,4.241121354187437,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DE15MT0(II),Trina Solar,Mono-c-Si,0,400.0,375.3,1.99,,,48.0,10.45,49.0,9.92,40.3,0.0044099,-0.126861,44.1,1.7688557297742622,10.455024224968259,9.67582168976174e-12,0.32538046640411283,676.7662542217568,4.241121354187437,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DEG15H(II),Trina Solar,Mono-c-Si,0,400.0,375.3,2.009928,,,48.0,10.18,50.4,9.74,41.1,0.0045301,-0.1332576,43.6,1.8328016665343987,10.180003702365802,1.161802499165258e-11,0.3636821885370121,999998.6153582212,3.755840055682586,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-400DEG15H20(II),Trina Solar,Mono-c-Si,0,400.0,375.3,2.009928,,,48.0,10.18,50.4,9.74,41.1,0.0045301,-0.1332576,43.6,1.8328016665343987,10.180003702365802,1.161802499165258e-11,0.3636821885370121,999998.6153582212,3.755840055682586,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-400DEG15HC(II),Trina Solar,Mono-c-Si,1,400.0,374.2,2.009928,,,48.0,10.39,49.9,9.83,40.7,0.00421834,-0.1346302,43.8,1.8373350195814766,10.397186936382191,1.651868274892493e-11,0.3639556862210426,526.1629487334129,4.524044367196953,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DEG15HC20(II),Trina Solar,Mono-c-Si,1,400.0,374.2,2.009928,,,48.0,10.39,49.9,9.83,40.7,0.00421834,-0.1346302,43.8,1.8373350195814766,10.397186936382191,1.651868274892493e-11,0.3639556862210426,526.1629487334129,4.524044367196953,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DEG15M(II),Trina Solar,Mono-c-Si,0,400.0,377.5,2.01,,,48.0,10.45,49.0,9.92,40.3,0.00404415,-0.12720399999999998,42.3,1.7668978488749687,10.455072332212048,9.382832283126439e-12,0.3258159218713558,671.2447597293468,3.7466012507793875,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DEG15M20(II),Trina Solar,Mono-c-Si,0,400.0,377.5,2.01,,,48.0,10.45,49.0,9.92,40.3,0.00404415,-0.12720399999999998,42.3,1.7668978488749687,10.455072332212048,9.382832283126439e-12,0.3258159218713558,671.2447597293468,3.7466012507793875,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DEG15MC(II),Trina Solar,Mono-c-Si,1,400.0,374.5,2.01,,,48.0,10.33,48.9,9.81,40.8,0.00415266,-0.13124760000000002,44.0,1.8017947384204491,10.333962974330895,1.6771896734592687e-11,0.2549510651965577,664.562603869805,5.251117618645504,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400DEG15MC20(II),Trina Solar,Mono-c-Si,1,400.0,374.5,2.01,,,48.0,10.33,48.9,9.81,40.8,0.00415266,-0.13124760000000002,44.0,1.8017947384204491,10.333962974330895,1.6771896734592687e-11,0.2549510651965577,664.562603869805,5.251117618645504,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-400NE09RC05,Trina Solar,Mono-c-Si,0,400.0,376.1,1.98,,,72.0,10.3,49.2,9.68,41.3,0.0047483000000000004,-0.12418080000000002,44.72,1.7659626303456935,10.311417654867078,8.01969431051163e-12,0.240760783834163,217.1931195762451,5.445561041152126,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE09,Trina Solar,Mono-c-Si,0,405.0,378.0,1.91,,,60.0,12.34,41.4,11.77,34.4,0.0040722,-0.110124,44.8,1.5229434411770644,12.340007616278628,1.929134385850767e-11,0.19413891546517242,314549.6012102761,5.950701379429463,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE0905,Trina Solar,Mono-c-Si,0,405.0,381.6,1.91,,,60.0,12.34,41.4,11.77,34.4,0.004565799999999999,-0.098118,44.3,1.4496666315979174,12.340009061712669,4.8820541784838426e-12,0.20796583267135443,283203.099168052,6.329928196352143,-0.317,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE0908,Trina Solar,Mono-c-Si,0,405.0,378.0,1.91,,,60.0,12.34,41.4,11.77,34.4,0.0040722,-0.110124,44.8,1.5229434411770644,12.340007616278628,1.929134385850767e-11,0.19413891546517242,314549.6012102761,5.950701379429463,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE09C05,Trina Solar,Mono-c-Si,0,405.0,378.0,1.91,,,60.0,12.34,41.4,11.77,34.4,0.0039488,-0.10602539999999999,45.58,1.4923265121435036,12.340009721746103,1.1044543637554086e-11,0.19988473835355094,253718.77389433546,5.211218449035347,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE09C07,Trina Solar,Mono-c-Si,0,405.0,378.0,1.91,,,60.0,12.34,41.4,11.77,34.4,0.0039488,-0.10602539999999999,45.58,1.4923265121435036,12.340009721746103,1.1044543637554086e-11,0.19988473835355094,253718.77389433546,5.211218449035347,-0.3424,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE15H(II),Trina Solar,Mono-c-Si,0,405.0,379.8,1.985912,,,48.0,10.23,50.8,9.79,41.4,0.00413292,-0.1372108,43.8,1.8464797129356962,10.230003751689232,1.1525138107919499e-11,0.3667259274377592,999998.2450925382,1.5016282767054194,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-405DE15HT0(II),Trina Solar,Mono-c-Si,0,405.0,379.8,1.99,,,48.0,10.23,50.8,9.79,41.4,0.00413292,-0.1372108,43.8,1.8464797129356962,10.230003751689232,1.1525138107919499e-11,0.3667259274377592,999998.2450925382,1.5016282767054194,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-405DE15M(II),Trina Solar,Mono-c-Si,0,405.0,380.1,1.99,,,48.0,10.52,49.2,10.0,40.5,0.00443944,-0.12737880000000001,44.1,1.775737608960993,10.523835927208188,9.703961934794813e-12,0.3204755189756127,878.9015850408559,4.203485093684556,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DE15MT0(II),Trina Solar,Mono-c-Si,0,405.0,380.1,1.99,,,48.0,10.52,49.2,10.0,40.5,0.00443944,-0.12737880000000001,44.1,1.775737608960993,10.523835927208188,9.703961934794813e-12,0.3204755189756127,878.9015850408559,4.203485093684556,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DEG15H(II),Trina Solar,Mono-c-Si,0,405.0,380.2,2.009928,,,48.0,10.23,50.8,9.79,41.4,0.00455235,-0.13431520000000002,43.6,1.8470290868363124,10.230003749883483,1.161983543499764e-11,0.36654936493639634,999998.2445417484,3.7158166746709296,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-405DEG15H20(II),Trina Solar,Mono-c-Si,0,405.0,380.2,2.009928,,,48.0,10.23,50.8,9.79,41.4,0.00455235,-0.13431520000000002,43.6,1.8470290868363124,10.230003749883483,1.161983543499764e-11,0.36654936493639634,999998.2445417484,3.7158166746709296,-0.3428,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-405DEG15HC20(II),Trina Solar,Mono-c-Si,1,405.0,379.0,2.01,,,48.0,10.49,50.1,9.93,40.8,0.00425894,-0.13516979999999998,43.8,1.842786871236256,10.496718451528398,1.6227181124160957e-11,0.3692576092367877,576.5484165099284,4.289350323293642,-0.3546,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DEG15M(II),Trina Solar,Mono-c-Si,0,405.0,382.3,2.01,,,48.0,10.52,49.2,10.0,40.5,0.00407124,-0.1277232,42.3,1.7737714956161783,10.52388226656932,9.409973808346321e-12,0.3209094610073788,869.5867520232423,3.708961569417062,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DEG15M20(II),Trina Solar,Mono-c-Si,0,405.0,382.3,2.01,,,48.0,10.52,49.2,10.0,40.5,0.00407124,-0.1277232,42.3,1.7737714956161783,10.52388226656932,9.409973808346321e-12,0.3209094610073788,869.5867520232423,3.708961569417062,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DEG15MC(II),Trina Solar,Mono-c-Si,1,405.0,379.3,2.01,,,48.0,10.37,49.1,9.86,41.1,0.00416874,-0.13178440000000002,44.0,1.8110567244662903,10.373110318848884,1.7340635263718366e-11,0.2396444991860113,798.9899484043001,5.498673346831821,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405DEG15MC20(II),Trina Solar,Mono-c-Si,1,405.0,379.3,2.01,,,48.0,10.37,49.1,9.86,41.1,0.00416874,-0.13178440000000002,44.0,1.8110567244662903,10.373110318848884,1.7340635263718366e-11,0.2396444991860113,798.9899484043001,5.498673346831821,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-405NE09RC05,Trina Solar,Mono-c-Si,0,405.0,380.9,1.98,,,72.0,10.33,49.6,9.71,41.7,0.004762130000000001,-0.1251904,44.72,1.7815152746052552,10.341035533068327,8.195441817462733e-12,0.23447688648047157,219.4861115954515,5.607044956500895,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DE09,Trina Solar,Mono-c-Si,0,410.0,382.8,1.91,,,60.0,12.4,41.6,11.85,34.6,0.004092000000000001,-0.11065600000000002,44.8,1.5018504418130383,12.40000479166806,1.158311568162687e-11,0.19618443909681843,507696.0348225658,1.6170716565556866,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DE0908,Trina Solar,Mono-c-Si,0,410.0,382.8,1.91,,,60.0,12.4,41.6,11.85,34.6,0.004092000000000001,-0.11065600000000002,44.8,1.5018504418130383,12.40000479166806,1.158311568162687e-11,0.19618443909681843,507696.0348225658,1.6170716565556866,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DE15H(II),Trina Solar,Mono-c-Si,0,410.0,384.6,1.985912,,,48.0,10.29,51.2,9.84,41.7,0.004157159999999999,-0.1382912,43.8,1.8599397399983382,10.290003847141577,1.1409148149284748e-11,0.37386384459312544,999999.034721043,1.3700343574099363,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-410DE15HT0(II),Trina Solar,Mono-c-Si,0,410.0,384.6,1.99,,,48.0,10.29,51.2,9.84,41.7,0.004157159999999999,-0.1382912,43.8,1.8599397399983382,10.290003847141577,1.1409148149284748e-11,0.37386384459312544,999999.034721043,1.3700343574099363,-0.3454,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-410DE15M(II),Trina Solar,Mono-c-Si,0,410.0,384.9,1.99,,,48.0,10.59,49.4,10.07,40.7,0.00446898,-0.1278966,44.1,1.7834385032749491,10.59356769751106,9.845133242291469e-12,0.31562810777948647,936.8792324012228,4.2686147203344476,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DE15MT0(II),Trina Solar,Mono-c-Si,0,410.0,384.9,1.99,,,48.0,10.59,49.4,10.07,40.7,0.00446898,-0.1278966,44.1,1.7834385032749491,10.59356769751106,9.845133242291469e-12,0.31562810777948647,936.8792324012228,4.2686147203344476,-0.3352,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DEG15M(II),Trina Solar,Mono-c-Si,0,410.0,387.1,2.01,,,48.0,10.59,49.4,10.07,40.7,0.00409833,-0.1282424,42.3,1.7814627075266847,10.593613429377994,9.546775967175083e-12,0.31606140390550014,926.2918868114641,3.7736537371468053,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DEG15M20(II),Trina Solar,Mono-c-Si,0,410.0,387.1,2.01,,,48.0,10.59,49.4,10.07,40.7,0.00409833,-0.1282424,42.3,1.7814627075266847,10.593613429377994,9.546775967175083e-12,0.31606140390550014,926.2918868114641,3.7736537371468053,-0.3373,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DEG15MC(II),Trina Solar,Mono-c-Si,1,410.0,384.1,2.01,,,48.0,10.41,49.3,9.91,41.4,0.00418482,-0.1323212,44.0,1.8203059896376415,10.412340421697325,1.7919711557055606e-11,0.22450381762963148,998.5742275742562,5.742602055487932,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410DEG15MC20(II),Trina Solar,Mono-c-Si,1,410.0,384.1,2.01,,,48.0,10.41,49.3,9.91,41.4,0.00418482,-0.1323212,44.0,1.8203059896376415,10.412340421697325,1.7919711557055606e-11,0.22450381762963148,998.5742275742562,5.742602055487932,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-410NE09RC05,Trina Solar,Mono-c-Si,0,410.0,385.7,1.98,,,72.0,10.37,50.1,9.73,42.1,0.0047805700000000005,-0.12645240000000002,44.72,1.8005995449964576,10.382275603975648,8.35423975196162e-12,0.23807353373552365,201.11613431545584,5.747068371820963,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-415DE15M(II),Trina Solar,Mono-c-Si,0,415.0,389.1,1.985912,,,48.0,10.66,49.6,10.15,40.9,0.00605488,-0.13168800000000003,45.2,1.7965324300399208,10.660006943885097,1.0900063221002565e-11,0.3094405453467935,475045.80892003287,2.236380022614715,-0.3256,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-415DEG15MC20(II),Trina Solar,Mono-c-Si,1,415.0,390.8,2.03,,,48.0,10.52,49.4,10.02,41.5,0.0053546800000000006,-0.1297244,44.0,1.7864298468639168,10.522643043413415,1.0241746895565516e-11,0.22920492425010458,912.2951980240061,3.059746356836557,-0.3203,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-415NE09RC05,Trina Solar,Mono-c-Si,0,415.0,390.5,1.98,,,72.0,10.4,50.5,9.77,42.5,0.004794400000000001,-0.12746200000000002,44.72,1.8152686654995522,10.41125935743656,8.426974313376433e-12,0.2319738301808549,214.26869628106084,5.792177941527605,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-415NEG9RH25,Trina Solar,Mono-c-Si,0,415.0,391.8,1.98,,,16.0,15.6,34.5,14.77,28.1,0.0066924,-0.08745750000000001,45.27,1.1780876247340175,15.615499981720562,2.9521929132330895e-12,0.18421132451553665,185.40000368920812,-6.535992878005736,-0.2912,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-420DE15M(II),Trina Solar,Mono-c-Si,0,420.0,393.9,1.985912,,,48.0,10.74,49.9,10.23,41.1,0.006100320000000001,-0.1324845,45.2,1.8067621672747254,10.740007098707842,1.0875589773490402e-11,0.3141784561521966,475340.72198446275,2.1552652630890763,-0.3256,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-420DEG15MC20(II),Trina Solar,Mono-c-Si,1,420.0,395.6,2.03,,,48.0,10.6,49.5,10.1,41.6,0.0053954,-0.129987,44.0,1.784253344693856,10.6000063298601,9.479830156907743e-12,0.22735748767536795,380735.06431637425,2.330557684656565,-0.3203,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-420NE09RC05,Trina Solar,Mono-c-Si,0,420.0,395.4,1.98,,,72.0,10.43,50.9,9.8,42.8,0.00480823,-0.12847160000000002,44.72,1.8287129484589293,10.441356738817456,8.33449780875559e-12,0.23743694775771065,218.0614884376964,5.670930787738878,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-420NEG9RH25,Trina Solar,Mono-c-Si,0,420.0,396.6,1.98,,,16.0,15.64,34.7,14.79,28.4,0.006709560000000001,-0.08796450000000001,45.27,1.1882907122356552,15.657060202707006,3.210302619989306e-12,0.17426732315455112,159.76017316338522,-5.897413151052934,-0.2912,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-425NE09RC05,Trina Solar,Mono-c-Si,0,425.0,400.2,1.98,,,72.0,10.47,51.4,9.84,43.2,0.004826670000000001,-0.1297336,44.72,1.846029771086547,10.481345866491194,8.28798804418666e-12,0.24126021609884013,222.6356494900046,5.588397870612571,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-425NEG9RH25,Trina Solar,Mono-c-Si,0,425.0,401.4,1.98,,,16.0,15.68,34.9,14.81,28.7,0.00672672,-0.0884715,45.27,1.1985082264321512,15.698294851394197,3.4873126938872483e-12,0.16435099811051085,140.86059506968158,-5.26345233631977,-0.2912,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-430NE09RC05,Trina Solar,Mono-c-Si,0,430.0,405.0,1.98,,,72.0,10.5,51.8,9.87,43.6,0.0048405,-0.1307432,44.72,1.861576790550229,10.510973407085622,8.460556539687616e-12,0.23507996506816187,224.93830942560854,5.741227866488629,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-430NEG9RH25,Trina Solar,Mono-c-Si,0,430.0,406.2,1.98,,,16.0,15.72,35.1,14.83,29.0,0.006743880000000001,-0.08897850000000002,45.27,1.208740128638857,15.739217287508907,3.784331735202117e-12,0.15446199804047828,126.35199484546882,-4.634039829850636,-0.2912,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-435NE09RC05,Trina Solar,Mono-c-Si,0,435.0,409.8,1.98,,,72.0,10.53,52.2,9.89,44.0,0.00485433,-0.1317528,44.72,1.8780299766823088,10.541190766812145,8.740403173840237e-12,0.22878396703347925,215.27525487818488,6.00199298069587,-0.3151,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-435NEG9RH25,Trina Solar,Mono-c-Si,0,435.0,411.1,1.98,,,16.0,15.76,35.3,14.85,29.3,0.006761039999999999,-0.0894855,45.27,1.2189863906511764,15.779840090502713,4.1025174473121e-12,0.14459998611876917,114.86316941043717,-4.0091058282194565,-0.2912,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-440NEG9RH25,Trina Solar,Mono-c-Si,0,440.0,415.9,1.98,,,16.0,15.8,35.5,14.87,29.6,0.0067782,-0.0899925,45.27,1.229246892312374,15.820174997343326,4.443068148852449e-12,0.13476465270896068,105.5406094356643,-3.388597217945958,-0.2912,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-445NEG9RH25,Trina Solar,Mono-c-Si,0,445.0,420.8,1.98,,,16.0,15.84,35.7,14.89,29.9,0.00679536,-0.09049950000000001,45.27,1.2395217039094601,15.860233253502596,4.80725106224766e-12,0.12495567495047634,97.82400506230488,-2.7724282187502394,-0.2912,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-450NEG9RH25,Trina Solar,Mono-c-Si,0,450.0,425.6,1.98,,,16.0,15.88,35.9,14.91,30.2,0.006812520000000001,-0.0910065,45.27,1.249810654082782,15.900025347094283,5.19636036646228e-12,0.11517277820906278,91.33143665002494,-2.1605588936612756,-0.2912,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-455NEG9RH25,Trina Solar,Mono-c-Si,0,455.0,430.5,1.98,,,16.0,15.92,36.1,14.93,30.5,0.00682968,-0.09151350000000001,45.27,1.260113609551631,15.939561083766602,5.611745141125858e-12,0.10541569265439088,85.79370367090264,-1.552942035253215,-0.2912,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-460NEG9RH25,Trina Solar,Mono-c-Si,0,460.0,435.3,1.98,,,16.0,15.96,36.3,14.94,30.8,0.006846840000000001,-0.0920205,45.27,1.2708378704092604,15.979373005015344,6.105738716013691e-12,0.0956313388917675,78.78365542062372,-0.8784142180510897,-0.2912,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-465DEG15VC20(II),Trina Solar,Mono-c-Si,0,465.0,437.3,2.33,,,126.0,13.58,43.0,12.99,35.8,0.0077406,-0.09933,45.8,1.4999754961420437,13.580005574913343,4.818573242545405e-12,0.19110853960760613,465525.5104327701,7.852549705588308,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-470DE15V(II),Trina Solar,Mono-c-Si,0,470.0,439.4,2.33,,,126.0,13.73,43.0,13.02,36.1,0.006453100000000001,-0.11825000000000001,43.7,1.6302254701663008,13.735126207499077,4.775112236394768e-11,0.14217013532639416,380.78755126252196,9.151664326775556,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-470DEG15VC20(II),Trina Solar,Mono-c-Si,0,470.0,442.1,2.33,,,126.0,13.68,43.1,13.09,35.9,0.007797600000000001,-0.09956100000000001,45.8,1.5042473092167912,13.680076198459023,4.926678635300596e-12,0.1885967239520799,33859.00547889926,7.985183781488282,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-475DE15V(II),Trina Solar,Mono-c-Si,0,475.0,444.2,2.33,,,126.0,13.8,43.1,13.12,36.2,0.0064860000000000004,-0.11852500000000002,43.7,1.6323275104653518,13.803187757206445,4.6841242377038574e-11,0.14064253228614243,608.8503255648803,8.926233647756096,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-475DEG15VC20(II),Trina Solar,Mono-c-Si,0,475.0,447.0,2.33,,,126.0,13.8,43.2,13.19,36.0,0.007866000000000001,-0.09979200000000002,45.8,1.5088038405110906,13.801252437132955,5.06471950264059e-12,0.1859211696064156,2048.575692933459,8.159183647982104,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-480DE15V(II),Trina Solar,Mono-c-Si,0,480.0,449.0,2.33,,,126.0,13.92,43.2,13.23,36.3,0.006542399999999999,-0.11880000000000002,43.7,1.636732626429856,13.923442498162448,4.770252350959476e-11,0.13832900854791075,559.3437575128987,9.011953486816484,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-480DE18M(II),Trina Solar,Mono-c-Si,0,480.0,449.1,2.34,,,75.0,11.99,50.8,11.42,42.0,0.0065945000000000005,-0.13426439999999998,45.0,1.8644438289345773,11.991873853847634,1.7567159592257152e-11,0.2664469681593818,1704.8817843958802,5.791997719561977,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-480DE18M08(II),Trina Solar,Mono-c-Si,0,480.0,449.1,2.34,,,75.0,11.97,50.7,11.38,42.2,0.006583500000000001,-0.13400009999999998,45.0,1.868660423871134,11.973650928263378,1.961996110610593e-11,0.23775517865315302,779.5084806290938,6.771903812571572,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-480DEG15VC20(II),Trina Solar,Mono-c-Si,0,480.0,451.8,2.33,,,126.0,13.92,43.3,13.29,36.1,0.0079344,-0.100023,45.8,1.5133551156366416,13.92240945809658,5.20519122238214e-12,0.18328747979505156,1058.8943925304177,8.331539967890762,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-480DEG18MC20(II),Trina Solar,Mono-c-Si,0,480.0,450.7,2.39,,,75.0,11.97,50.7,11.38,42.2,0.007098210000000001,-0.1335945,44.2,1.862061937853403,11.973791311953873,1.7818450302220654e-11,0.2390385071019774,754.696793327972,6.206050783396248,-0.3296,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-485DE15V(II),Trina Solar,Mono-c-Si,0,485.0,453.8,2.33,,,126.0,13.97,43.3,13.33,36.4,0.006565900000000001,-0.11907500000000001,43.7,1.6377268936932479,13.970471167880138,4.5976026676570784e-11,0.13719055142740047,4067.662023217908,8.638959870880893,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-485DE18M(II),Trina Solar,Mono-c-Si,0,485.0,453.9,2.34,,,75.0,12.07,51.1,11.49,42.2,0.0066385,-0.1350573,45.0,1.8748583321951762,12.07234972489483,1.7522768751706214e-11,0.2710228364241952,1392.1824452899573,5.714882215471886,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-485DE18M08(II),Trina Solar,Mono-c-Si,0,485.0,453.9,2.34,,,75.0,12.01,50.9,11.42,42.5,0.0066055,-0.1345287,45.0,1.8716662569686406,12.010006309515708,1.8573430753784724e-11,0.22576607738662702,429744.0113829115,6.2495105606601316,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-485DEG15VC20(II),Trina Solar,Mono-c-Si,0,485.0,456.6,2.33,,,126.0,13.97,43.4,13.39,36.2,0.007962900000000002,-0.10025400000000001,45.8,1.5164802091618237,13.970002477917049,5.201917797589614e-12,0.17737243877394632,999998.9595749588,8.282795202163673,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-485DEG18MC20(II),Trina Solar,Mono-c-Si,0,485.0,455.5,2.39,,,75.0,12.01,50.9,11.42,42.5,0.007121929999999999,-0.1341215,44.2,1.8649265721430162,12.01000635833756,1.683485805357262e-11,0.22707376335734536,428913.97587211715,5.668284511316798,-0.3296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-490DE15V(II),Trina Solar,Mono-c-Si,0,490.0,458.6,2.33,,,126.0,14.07,43.4,13.43,36.5,0.0066129000000000005,-0.11935000000000001,43.7,1.6416016425575082,14.07023849336638,4.6390781798205005e-11,0.13520188560608506,7976.286005220676,8.65382885828618,-0.362,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-490DE18M(II),Trina Solar,Mono-c-Si,0,490.0,458.7,2.34,,,75.0,12.14,51.3,11.56,42.4,0.006677000000000001,-0.13558589999999998,45.0,1.882715225221572,12.142119272856778,1.7761890073219638e-11,0.2670641680183342,1529.845070748204,5.780809543572297,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-490DEG15VC20(II),Trina Solar,Mono-c-Si,0,490.0,461.4,2.33,,,126.0,14.07,43.5,13.49,36.3,0.008019900000000002,-0.100485,45.8,1.520438659381321,14.070002452707332,5.285137695528195e-12,0.17432003299654766,999998.6995963183,8.360900021922669,-0.296,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-490DEG18MC20(II),Trina Solar,Mono-c-Si,0,490.0,460.3,2.39,,,75.0,12.05,51.1,11.45,42.8,0.007145650000000001,-0.1346485,44.2,1.883113390705413,12.05413464633644,1.9641581875301283e-11,0.2125305778353944,619.3984417878,6.997976529356758,-0.3296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-495DE18M(II),Trina Solar,Mono-c-Si,0,495.0,463.5,2.34,,,75.0,12.21,51.5,11.63,42.6,0.006715500000000001,-0.1361145,45.0,1.8873782401431722,12.210003447685216,1.7231579941443897e-11,0.26370033359387873,933917.5121804606,5.461535723807341,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-495DE18M08(II),Trina Solar,Mono-c-Si,0,495.0,463.5,2.34,,,75.0,12.09,51.3,11.49,43.1,0.0066495,-0.13558589999999998,45.0,1.8910077824543137,12.090005370779075,1.9985339875557923e-11,0.1997524267649565,449661.03563438996,6.826623388111785,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-495DEG18MC20(II),Trina Solar,Mono-c-Si,0,495.0,465.2,2.39,,,75.0,12.09,51.3,11.49,43.1,0.00716937,-0.1351755,44.2,1.8842119958921983,12.090005414412248,1.8122513937973178e-11,0.20106974246260745,448978.48581006186,6.246955175115127,-0.3296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-500DE18M(II),Trina Solar,Mono-c-Si,0,500.0,468.3,2.34,,,75.0,12.28,51.7,11.69,42.8,0.006754,-0.1366431,45.0,1.8949542137042161,12.280007382520273,1.7391869081914433e-11,0.25996952508024473,432434.81525420217,5.491959055450695,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-500DE18M08(II),Trina Solar,Mono-c-Si,0,500.0,468.3,2.34,,,75.0,12.13,51.5,11.53,43.4,0.0066715,-0.1361145,45.0,1.9009897987171631,12.130004967462407,2.0812293134477084e-11,0.18680601864422894,456164.25366196554,7.150448574249815,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-500DEG18MC20(II),Trina Solar,Mono-c-Si,0,500.0,470.0,2.39,,,75.0,12.13,51.5,11.53,43.4,0.00719309,-0.1357025,44.2,1.8941555586905818,12.13000500978551,1.8874223130839258e-11,0.18812914748223683,455513.841514316,6.570386312215655,-0.3296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-505DE18M(II),Trina Solar,Mono-c-Si,0,505.0,473.1,2.34,,,75.0,12.35,51.9,11.75,43.0,0.0067925,-0.1371717,45.0,1.9078405954677806,12.35304799923527,1.8865308846039766e-11,0.2553733347211317,1034.7314821300324,6.156969725790516,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-505DE18M08(II),Trina Solar,Mono-c-Si,0,505.0,473.1,2.34,,,75.0,12.35,51.9,11.75,43.0,0.0067925,-0.1371717,45.0,1.9078405954677806,12.35304799923527,1.8865308846039766e-11,0.2553733347211317,1034.7314821300324,6.156969725790516,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-505DEG18MC20(II),Trina Solar,Mono-c-Si,0,505.0,474.8,2.39,,,75.0,12.17,51.7,11.56,43.7,0.00721681,-0.1362295,44.2,1.9034845220254637,12.170004616320599,1.947772560031382e-11,0.17540469786118668,462423.2146206889,6.815094714141658,-0.3296,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-510DE18M08(II),Trina Solar,Mono-c-Si,0,510.0,477.9,2.34,,,75.0,12.42,52.1,11.81,43.2,0.006831,-0.1377003,45.0,1.9164210535970116,12.423600539145829,1.9291834989516356e-11,0.2515526700686287,867.7267781532901,6.3039568496641065,-0.3365,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-525NEG19RC20,Trina Solar,Mono-c-Si,1,525.0,491.6,2.68,,,66.0,15.45,44.1,14.53,36.2,0.0066744000000000005,-0.1100736,45.69,1.5605748054313848,15.472155950779568,8.097094553864486e-12,0.209119211659967,145.82500751573747,3.2687460715053507,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-530DEG19C20,Trina Solar,Mono-c-Si,1,530.0,498.6,2.59,,,55.0,18.19,37.3,17.11,31.0,0.006366500000000001,-0.090266,44.3,1.322380196345111,18.212844116857507,1.0031303338113522e-11,0.12540076295711095,99.85239950312581,7.100146978243246,-0.321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-530NEG19RC20,Trina Solar,Mono-c-Si,1,530.0,496.4,2.68,,,66.0,15.46,44.3,14.56,36.4,0.006678720000000001,-0.1105728,45.69,1.5673914716677728,15.480000095373267,8.076937836095155e-12,0.2071069239756939,160.09288923810362,3.2364160744316646,-0.3158,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-535DE19,Trina Solar,Mono-c-Si,0,535.0,495.8,2.59,,,55.0,18.36,37.3,17.28,31.0,0.0080784,-0.098845,45.7,1.4192210393003981,18.37646182243506,6.966173395885663e-11,0.11176449141963843,124.65181778875342,14.166203812701278,-0.371,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-535DEG19C20,Trina Solar,Mono-c-Si,1,535.0,503.4,2.59,,,55.0,18.24,37.5,17.16,31.2,0.006384,-0.09075,44.3,1.3300612923258328,18.262356435512054,1.0186676759322455e-11,0.12348254970104842,100.74601158254526,7.210255952188794,-0.321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-535NEG19RC20,Trina Solar,Mono-c-Si,1,535.0,501.2,2.68,,,66.0,15.47,44.5,14.58,36.7,0.00668304,-0.11107199999999999,45.69,1.5767920579283847,15.48836408325634,8.430122044029126e-12,0.19725218174088358,166.16627235029057,3.591763875929451,-0.3158,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-540DE19,Trina Solar,Mono-c-Si,0,540.0,500.6,2.59,,,55.0,18.41,37.5,17.33,31.2,0.0081004,-0.099375,45.7,1.4275086876125636,18.426061635196238,7.073527236566244e-11,0.10981729722734733,125.87363895697598,14.281831938373205,-0.371,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-540DEG19C20,Trina Solar,Mono-c-Si,1,540.0,508.2,2.59,,,55.0,18.3,37.7,17.21,31.4,0.006405000000000002,-0.09123400000000001,44.3,1.3380806296979109,18.322604476993796,1.0415865254124515e-11,0.12149280465995735,98.35743291788143,7.37872635939598,-0.321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-540NEG19RC20,Trina Solar,Mono-c-Si,1,540.0,506.0,2.68,,,66.0,15.49,44.8,14.6,37.0,0.006691680000000001,-0.11182079999999998,45.69,1.5884665392828496,15.50802784736874,8.598725145559136e-12,0.19420412656524655,166.86528718503678,3.749116060246881,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-545DE19,Trina Solar,Mono-c-Si,0,545.0,505.3,2.59,,,55.0,18.47,37.7,17.37,31.4,0.0081268,-0.09990500000000002,45.7,1.4365876975832306,18.487000721452226,7.280428562479301e-11,0.10775965947701326,117.07273374687638,14.522807967703265,-0.371,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-545DEG19C20,Trina Solar,Mono-c-Si,1,545.0,513.0,2.59,,,55.0,18.35,37.9,17.24,31.6,0.006422500000000001,-0.091718,44.3,1.346487535755192,18.373609085121043,1.0720740795486835e-11,0.11955847734429915,92.9260075889598,7.613399475066267,-0.321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-545NEG19RC20,Trina Solar,Mono-c-Si,1,545.0,510.8,2.68,,,66.0,15.51,45.1,14.62,37.3,0.00670032,-0.11256959999999999,45.69,1.6001394436448004,15.527692641719844,8.768088808237665e-12,0.19116551176615112,167.58249799941947,3.9041320864472144,-0.3158,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-550DE19,Trina Solar,Mono-c-Si,0,550.0,510.1,2.59,,,55.0,18.52,37.9,17.4,31.6,0.0081488,-0.10043500000000001,45.7,1.4456993364505248,18.537915870969343,7.490917803524096e-11,0.10576474099997339,109.3311639846177,14.766446637690445,-0.371,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-550DEG19C20,Trina Solar,Mono-c-Si,1,550.0,517.9,2.59,,,55.0,18.39,38.1,17.29,31.8,0.006436500000000001,-0.09220199999999999,44.3,1.3538257888633562,18.412397630791315,1.0804279815861233e-11,0.11775600685362005,96.68580530296148,7.6595430791023285,-0.321,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-550NEG19RC20,Trina Solar,Mono-c-Si,1,550.0,515.6,2.68,,,66.0,15.53,45.4,14.65,37.6,0.00670896,-0.1133184,45.69,1.6113032770958642,15.546519749316891,8.866326839600585e-12,0.18815299048136144,176.88015991944553,3.9851614446231163,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-555NEG19RC20,Trina Solar,Mono-c-Si,1,555.0,520.4,2.68,,,66.0,15.55,45.7,14.68,37.8,0.006717600000000001,-0.1140672,45.69,1.6203728621670768,15.565807957547316,8.646227206618245e-12,0.19294648794997213,189.79791600343972,3.756610705453954,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-560NEG19RC20,Trina Solar,Mono-c-Si,1,560.0,525.2,2.68,,,66.0,15.57,46.0,14.7,38.1,0.0067262400000000005,-0.114816,45.69,1.6320349351085028,15.585520232712216,8.811705334730537e-12,0.18993005728638337,190.5390865327702,3.9070293900327946,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-565NEG19RC20,Trina Solar,Mono-c-Si,1,565.0,530.0,2.68,,,66.0,15.59,46.3,14.72,38.4,0.006734880000000001,-0.11556479999999998,45.69,1.643695185249739,15.60523287620741,8.977820670363154e-12,0.18692289092499542,191.30516378727356,4.055243016942,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-570NEG19RC20,Trina Solar,Mono-c-Si,1,570.0,534.9,2.68,,,66.0,15.61,46.6,14.75,38.6,0.00674352,-0.1163136,45.69,1.6527552063427307,15.624523554298992,8.757746115157429e-12,0.19169829137490105,206.0384308124848,3.8293358596138165,-0.3158,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-575NEG19RC20,Trina Solar,Mono-c-Si,1,575.0,539.7,2.68,,,66.0,15.63,46.9,14.78,38.9,0.006752160000000001,-0.11706239999999998,45.69,1.6638924540193152,15.643443350201508,8.849819539584956e-12,0.1887196760634982,219.41617990696668,3.9045501271978633,-0.3158,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-580DEG20C20,Trina Solar,Mono-c-Si,1,580.0,547.1,2.81,,,60.0,18.21,40.9,17.16,33.8,0.0071019,-0.098978,43.9,1.4406824759485954,18.23198886286178,8.387487477456585e-12,0.1507298072690687,124.8263638558103,5.466810917854803,-0.315,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-580NEG19RC20,Trina Solar,Mono-c-Si,1,580.0,544.5,2.68,,,66.0,15.65,47.2,14.79,39.2,0.0067608,-0.1178112,45.69,1.6760636450751498,15.663999829647965,9.084261036120197e-12,0.18571189728736448,207.60189758874083,4.119437237620065,-0.3158,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-585DE20,Trina Solar,Mono-c-Si,0,585.0,549.4,2.81,,,60.0,18.37,40.9,17.31,33.8,0.01124244,-0.105931,44.4,1.504387417082694,18.388521618736892,2.8207731561897826e-11,0.1412334686946376,140.07732666314746,8.35009392654171,-0.3298,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-585DEG20C20,Trina Solar,Mono-c-Si,1,585.0,551.9,2.81,,,60.0,18.26,41.1,17.21,34.0,0.007121400000000001,-0.09946200000000001,43.9,1.4483293669244763,18.281564279447984,8.511184497688877e-12,0.14874837296443819,125.95576415258586,5.569362891216127,-0.315,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-585NEG19RC20,Trina Solar,Mono-c-Si,1,585.0,549.3,2.68,,,66.0,15.68,47.5,14.82,39.5,0.00677376,-0.11856,45.69,1.6876868149901936,15.693704648907314,9.250304574328419e-12,0.18261714989321623,208.93909342704015,4.257539207595009,-0.3158,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-590DE20,Trina Solar,Mono-c-Si,0,590.0,554.2,2.81,,,60.0,18.42,41.1,17.35,34.0,0.011273040000000002,-0.10644900000000002,44.4,1.5128169115841572,18.438951776679172,2.8818455895346186e-11,0.13922559674147073,135.31900215727177,8.517360799819329,-0.3298,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-590DEG20C20,Trina Solar,Mono-c-Si,1,590.0,556.7,2.81,,,60.0,18.31,41.3,17.25,34.2,0.0071408999999999995,-0.099946,43.9,1.4563605723022395,18.331993724282547,8.694555640092914e-12,0.14676980894269676,122.18736458141503,5.732560109538222,-0.315,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-590NEG19RC20,Trina Solar,Mono-c-Si,1,590.0,554.1,2.68,,,66.0,15.72,47.8,14.86,39.7,0.006791040000000001,-0.11930879999999999,45.69,1.697202320030744,15.733748800558823,9.10233047167453e-12,0.1871134606867962,213.9403796331146,4.0972066339146735,-0.3158,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-595DE20,Trina Solar,Mono-c-Si,0,595.0,559.0,2.81,,,60.0,18.47,41.3,17.4,34.2,0.01130364,-0.10696699999999999,44.4,1.5208328980835957,18.488557367215027,2.9239273847533076e-11,0.13724584602387002,136.59969993823574,8.621257477234147,-0.3298,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-595DEG20C20,Trina Solar,Mono-c-Si,1,595.0,561.5,2.81,,,60.0,18.36,41.5,17.3,34.4,0.007160399999999999,-0.10043,43.9,1.464006541770531,18.38156586160578,8.819973070524258e-12,0.14481085745284608,123.28407726205144,5.83269300700931,-0.315,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-595NEG19RC20,Trina Solar,Mono-c-Si,1,595.0,560.2,2.68,,,66.0,15.76,48.1,14.89,40.0,0.006698,-0.1195766,45.16,1.7024489120670656,15.774475163457405,8.337274124745918e-12,0.18492770721061103,201.3421596689905,3.762106942560412,-0.3132,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-600DE20,Trina Solar,Mono-c-Si,0,600.0,563.9,2.81,,,60.0,18.52,41.5,17.44,34.4,0.011334239999999999,-0.10748500000000001,44.4,1.5292647701192466,18.538954507398206,2.9862041029516353e-11,0.1352572934690819,132.15669701224937,8.785967036973844,-0.3298,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-600DEG20C20,Trina Solar,Mono-c-Si,1,600.0,566.4,2.81,,,60.0,18.42,41.7,17.34,34.6,0.0071838000000000015,-0.100914,43.9,1.4724073813357064,18.44274763032421,9.070008640932904e-12,0.1427620750517447,115.60225791345802,6.051798593548072,-0.315,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-600NEG19RC20,Trina Solar,Mono-c-Si,1,600.0,565.0,2.68,,,66.0,15.8,48.4,14.91,40.3,0.0067150000000000005,-0.1203224,45.16,1.715053672105776,15.815670971515763,8.623446774696021e-12,0.18169503366063325,183.19103801709602,4.033501663541966,-0.3132,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-605NEG19RC20,Trina Solar,Mono-c-Si,1,605.0,574.3,2.68,,,66.0,15.83,48.7,14.94,40.5,0.006332,-0.11590600000000001,44.2,1.6625859229371722,15.848345192697034,2.9564847137537827e-12,0.19568290460581256,168.85406622670317,-0.45102482271648603,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-610NEG19RC20,Trina Solar,Mono-c-Si,1,610.0,574.7,2.68,,,66.0,15.86,49.0,14.96,40.8,0.0067405,-0.12181399999999999,45.16,1.7366787841814093,15.87623616625066,8.7030473678868e-12,0.18320106382067788,178.95658573488157,4.081474499135129,-0.3132,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-615NEG19RC20,Trina Solar,Mono-c-Si,1,615.0,579.5,2.68,,,66.0,15.89,49.3,14.98,41.1,0.0067532500000000014,-0.1225598,45.16,1.7487991337053759,15.906639183586984,8.924514488293748e-12,0.18012211602626893,172.0120703890655,4.2826258416280005,-0.3132,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-620NEG19RC20,Trina Solar,Mono-c-Si,1,620.0,584.3,2.68,,,66.0,15.91,49.6,14.99,41.4,0.00676175,-0.1233056,45.16,1.7609574449112826,15.92704278683884,9.147991798804148e-12,0.17715916819964134,165.3838880493819,4.486289613503225,-0.3132,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-625NEG19RC20,Trina Solar,Mono-c-Si,1,625.0,593.8,2.68,,,66.0,15.92,49.9,15.0,41.7,0.006368,-0.11876199999999999,44.2,1.7087117407034766,15.93925960190486,3.2404885121559563e-12,0.1840297782079444,152.11913864771532,0.2709514377111217,-0.287,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar TSM-630NEG19RC20,Trina Solar,Mono-c-Si,1,630.0,595.1,2.68,,,22.0,16.38,48.9,15.49,40.68,0.00681408,-0.1194138,45.85,1.685929180129837,16.395642252853357,4.087177525331166e-12,0.18631373516582014,195.1009879844822,-0.6740067363621284,-0.2931,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-635NEG19RC20,Trina Solar,Mono-c-Si,1,635.0,600.0,2.68,,,22.0,16.44,49.1,15.55,40.84,0.00683904,-0.11990220000000001,45.85,1.6925397734194312,16.455461842938004,4.083232431394352e-12,0.1868646828312131,198.68623696582605,-0.7129203362900304,-0.2931,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-640NEG19RC20,Trina Solar,Mono-c-Si,1,640.0,604.8,2.68,,,22.0,16.51,49.3,15.6,41.06,0.006868160000000001,-0.1203906,45.85,1.7012834122611127,16.526592392446855,4.226359875107983e-12,0.18289326262365377,181.98507295380475,-0.4597901631862975,-0.2931,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-645DE21,Trina Solar,Mono-c-Si,0,645.0,611.3,3.084266,,,44.0,18.39,45.1,17.35,37.2,0.005884800000000001,-0.096514,43.3,1.5396393760315727,18.413443700216252,3.433424748143897e-12,0.17532198084356335,137.52825711527075,10.899301813400077,-0.301,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-645DEG21C20,Trina Solar,Mono-c-Si,1,645.0,608.7,3.08,,,66.0,18.31,45.3,17.23,37.5,0.0062254,-0.104643,44.6,1.563031397480051,18.335760817981,4.648831280028203e-12,0.16636117451394894,118.24442495967104,5.3219194806537855,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-645NEG19RC20,Trina Solar,Mono-c-Si,1,645.0,609.7,2.68,,,22.0,16.55,49.52,15.65,41.22,0.0068848,-0.12092784000000001,45.85,1.707818146881634,16.565764773063556,4.165283602482414e-12,0.18497559599296534,194.18903814267185,-0.6029273472468789,-0.2931,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-650DE21,Trina Solar,Mono-c-Si,0,650.0,616.1,3.084266,,,44.0,18.44,45.3,17.39,37.4,0.0059008,-0.09694199999999999,43.3,1.5474053976470148,18.463962859627124,3.502463301665055e-12,0.17333456505298517,133.38513981486506,11.059913290308934,-0.301,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-650DEG21C20,Trina Solar,Mono-c-Si,1,650.0,613.5,3.08,,,66.0,18.35,45.5,17.27,37.7,0.0062390000000000015,-0.105105,44.6,1.5705103168345547,18.37534600762116,4.7093064354328965e-12,0.16446112295114795,119.0665470685093,5.415004889527722,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-650NEG19RC20,Trina Solar,Mono-c-Si,1,650.0,614.6,2.68,,,22.0,16.59,49.77,15.69,41.43,0.006901439999999999,-0.12153834000000001,45.85,1.7163702670097347,16.60562106920478,4.171091295076289e-12,0.185326682994753,196.82197387899183,-0.6119052293474618,-0.2931,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar TSM-655DE21,Trina Solar,Mono-c-Si,0,655.0,621.0,3.084266,,,44.0,18.48,45.5,17.43,37.6,0.005913600000000001,-0.09737,43.3,1.5548086395702942,18.503588438939317,3.548260354263049e-12,0.1714466841764657,134.3172702064867,11.159205848953373,-0.301,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-655DEG21C20,Trina Solar,Mono-c-Si,1,655.0,618.3,3.08,,,66.0,18.4,45.7,17.31,37.9,0.006256,-0.10556700000000001,44.6,1.578372557078595,18.4257503379325,4.803291906466163e-12,0.16247508601996818,116.0971787535481,5.565554311119781,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-660DE21,Trina Solar,Mono-c-Si,0,660.0,625.8,3.084266,,,44.0,18.53,45.7,17.47,37.8,0.005929600000000001,-0.097798,43.3,1.562577402526439,18.554077222554536,3.6186273248929403e-12,0.16947699655098233,130.43068991974022,11.317656379721095,-0.301,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-660DEG21C20,Trina Solar,Mono-c-Si,1,660.0,623.1,3.08,,,66.0,18.45,45.9,17.35,38.1,0.006273,-0.10602900000000001,44.6,1.5862370608815943,18.47613453119358,4.898481135234551e-12,0.16049781918447656,113.3054480689434,5.715136898969635,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-665DE21,Trina Solar,Mono-c-Si,0,665.0,630.7,3.084266,,,44.0,18.57,45.9,17.51,38.0,0.0059424000000000005,-0.09822600000000001,43.3,1.569980229952114,18.593697985453556,3.665015055117876e-12,0.16760712165603556,131.33876962904102,11.414875935917436,-0.301,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-665DEG21C20,Trina Solar,Mono-c-Si,1,665.0,628.0,3.08,,,66.0,18.5,46.1,17.39,38.3,0.0062900000000000005,-0.10649100000000002,44.6,1.594103807722131,18.526498920571203,4.99487942774483e-12,0.15852925878311952,110.6758776361132,5.863772428892081,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-670DE21,Trina Solar,Mono-c-Si,0,670.0,635.5,3.084266,,,44.0,18.62,46.1,17.55,38.2,0.0059584,-0.098654,43.3,1.5777516575408714,18.644157378075214,3.736708130561128e-12,0.16565489398856637,127.68331560456478,11.57128463198345,-0.301,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-670DEG21C20,Trina Solar,Mono-c-Si,1,670.0,632.8,3.08,,,66.0,18.55,46.3,17.43,38.5,0.006307,-0.10695299999999999,44.6,1.6019727853064263,18.57684383093504,5.092492488467956e-12,0.1565693454170544,108.19474192676014,6.011468511740127,-0.303,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-730NEG21C20,Trina Solar,Mono-c-Si,1,730.0,689.5,3.11,,,22.0,18.58,49.9,17.51,41.7,0.008082299999999999,-0.1188618,45.98,1.7257027584807614,18.601386976783573,5.045191073756372e-12,0.15545179277222212,135.04920970972182,2.5463424646210546,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-735NEG21C20,Trina Solar,Mono-c-Si,1,735.0,694.4,3.11,,,22.0,18.62,50.1,17.55,41.9,0.0080997,-0.11933819999999999,45.98,1.7331596382479637,18.641031695250263,5.102259456714584e-12,0.15361379387624854,135.99896779505536,2.6237199801689752,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar TSM-740NEG21C20,Trina Solar,Mono-c-Si,1,740.0,699.2,3.11,,,22.0,18.66,50.3,17.58,42.1,0.0081171,-0.1198146,45.98,1.7410662967805377,18.681402215337375,5.194752909111652e-12,0.15176113947358424,132.31634299814013,2.760137168221456,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-415NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,415.0,390.1,1.98,,,48.0,15.75,33.4,14.78,28.1,0.005922,-0.0797926,45.4,1.1793065848239979,15.769372590925348,7.708350722057559e-12,0.10527126413509119,85.58597687509166,7.425549872409151,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-420NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,420.0,394.9,1.98,,,48.0,15.8,33.7,14.84,28.3,0.0059408,-0.0805093,45.4,1.1883506574126201,15.819216262836374,7.46158167278226e-12,0.10995228440237817,90.4049924059554,7.106899081654458,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-425NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,425.0,399.7,1.98,,,48.0,15.84,33.9,14.88,28.5,0.0059558400000000004,-0.08098709999999999,45.4,1.1959587466920751,15.858740998188088,7.580350750437944e-12,0.1078791027248187,91.18002965439767,7.223026073968043,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-430NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,430.0,404.6,1.98,,,48.0,15.89,34.3,14.93,28.8,0.005974640000000001,-0.0819427,45.4,1.2092238562593816,15.909009467243983,7.457492209720426e-12,0.11158876679136552,93.27697004209284,7.050473281744544,-0.31,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar CoLtd TSM-435NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,435.0,409.4,1.98,,,48.0,15.96,34.5,14.99,29.1,0.006000960000000001,-0.08242050000000001,45.4,1.219156617059965,15.977949985894877,8.002938536617274e-12,0.10168897607880707,90.41545036649752,7.636099711402016,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-440NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,440.0,414.2,1.98,,,48.0,16.01,34.8,15.02,29.3,0.006019760000000001,-0.0831372,45.4,1.2293392490447033,16.029670786248555,7.941775843262064e-12,0.10620670881191517,86.44135464285408,7.545563372818613,-0.31,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-445NE09RH05,Trina Solar CoLtd,Mono-c-Si,0,445.0,419.0,1.98,,,48.0,16.07,35.1,15.08,29.5,0.00604232,-0.08385390000000001,45.4,1.238731054096904,16.090146754114638,7.758326553761705e-12,0.11071086403102347,88.30819973216043,7.305180798985219,-0.31,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-565NE19RC,Trina Solar CoLtd,Mono-c-Si,1,565.0,534.7,2.68,,,66.0,15.59,46.3,14.72,38.4,0.006080100000000001,-0.10986989999999999,44.0,1.598831707442183,15.607148720575472,4.067883646639951e-12,0.19379011980183009,176.17570701121002,2.6539233707433616,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-570NE19RC,Trina Solar CoLtd,Mono-c-Si,1,570.0,539.5,2.68,,,66.0,15.61,46.6,14.75,38.6,0.006087899999999999,-0.11058180000000001,44.0,1.60769224924518,15.626434164409137,3.968551706173972e-12,0.1985744192573842,188.6160145124757,2.429831219029457,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-575NE19RC,Trina Solar CoLtd,Mono-c-Si,1,575.0,544.4,2.68,,,66.0,15.63,46.9,14.78,38.9,0.006095700000000001,-0.1112937,44.0,1.618509910111243,15.645296589461758,4.0100793856465494e-12,0.19563609371145424,199.90025599197529,2.504132102495798,-0.2986,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar CoLtd TSM-580NE19RC,Trina Solar CoLtd,Mono-c-Si,1,580.0,549.2,2.68,,,66.0,15.65,47.2,14.79,39.2,0.0061035,-0.11200560000000001,44.0,1.630303151842627,15.66585579894047,4.1159321138048506e-12,0.1926888665087452,190.18787867111078,2.7172704789401365,-0.2986,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar CoLtd TSM-585NE19RC,Trina Solar CoLtd,Mono-c-Si,1,585.0,554.0,2.68,,,66.0,15.68,47.5,14.82,39.5,0.0061151999999999995,-0.11271750000000001,44.0,1.641579560187831,15.695533533291666,4.1909028974028014e-12,0.18963921977888823,191.42734065434675,2.854129647318873,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-590NE19RC,Trina Solar CoLtd,Mono-c-Si,1,590.0,558.9,2.68,,,66.0,15.72,47.8,14.86,39.7,0.0061308000000000005,-0.1134294,44.0,1.6508696390843856,15.735600742534555,4.1241530571772645e-12,0.1941441981368027,195.62830373394985,2.6951767801332465,-0.2986,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar CoLtd TSM-595NE19RC,Trina Solar CoLtd,Mono-c-Si,1,595.0,563.7,2.68,,,66.0,15.76,48.1,14.89,40.0,0.0061464,-0.11414130000000001,44.0,1.6626168811857926,15.77606353227029,4.2325781674692135e-12,0.1909707176414517,187.3621855840522,2.8966775365770507,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-600NE19RC,Trina Solar CoLtd,Mono-c-Si,1,600.0,568.6,2.68,,,66.0,15.8,48.4,14.91,40.3,0.006162,-0.1148532,44.0,1.6748739179100858,15.817287350560111,4.3773247287845675e-12,0.18778987834134903,171.63301404423046,3.1669391215788205,-0.2986,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar CoLtd TSM-605NE19RC,Trina Solar CoLtd,Mono-c-Si,1,605.0,573.4,2.68,,,66.0,15.83,48.7,14.94,40.5,0.0061737,-0.11556510000000002,44.0,1.684192193667874,15.84743739645763,4.3074146066274595e-12,0.19239296795616787,174.6579939129159,3.012896600569635,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-610NE19RC,Trina Solar CoLtd,Mono-c-Si,1,610.0,578.3,2.68,,,66.0,15.86,49.0,14.96,40.8,0.0061854,-0.116277,44.0,1.695983042503131,15.877875546945718,4.417657990503236e-12,0.18935421777163233,168.00369278916628,3.21478629272358,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-615NE19RC,Trina Solar CoLtd,Mono-c-Si,1,615.0,583.1,2.68,,,66.0,15.89,49.3,14.98,41.1,0.0061971000000000005,-0.1169889,44.0,1.7077799881737732,15.908282342988857,4.5296816209984805e-12,0.1863222109711578,161.94094693161844,3.415068713087771,-0.2986,N,2025.7.3,6/23/2025,2.0,first_pass +Trina Solar CoLtd TSM-620NE19RC,Trina Solar CoLtd,Mono-c-Si,1,620.0,588.0,2.68,,,66.0,15.91,49.6,14.99,41.4,0.006204899999999999,-0.11770080000000002,44.0,1.7196129945397727,15.928690515685588,4.642706491758521e-12,0.18341060601074183,156.12531921363197,3.6178545314769925,-0.2986,N,2025.7.3,6/23/2025,4.0,first_pass +Trina Solar CoLtd TSM-635NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,635.0,599.9,3.08,,,66.0,17.84,45.6,16.84,37.7,0.0073144,-0.110808,44.3,1.580501685676271,17.860234725065375,5.182025622300622e-12,0.1737912930818935,153.22356313427449,1.0922641387997767,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-640NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,640.0,604.7,3.08,,,66.0,17.88,45.8,16.88,37.9,0.0073308,-0.11129399999999999,44.3,1.588030822125607,17.899900966264113,5.250655220345418e-12,0.17182318569872415,154.37434164392747,1.1830634978716938,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-645NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,645.0,609.6,3.08,,,66.0,17.92,46.0,16.92,38.1,0.007347200000000002,-0.11178,44.3,1.5955589853494008,17.939570778536677,5.319531114121006e-12,0.1698648669569033,155.53691004223293,1.272940238800533,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-650NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,650.0,614.4,3.08,,,66.0,17.96,46.2,16.96,38.3,0.0073636000000000005,-0.112266,44.3,1.6030862352282567,17.97924414312644,5.388653194454144e-12,0.1679162749963259,156.71138402045372,1.3618542489159928,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-655NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,655.0,619.2,3.08,,,66.0,18.0,46.4,16.99,38.6,0.00738,-0.11275199999999999,44.3,1.6130339309810726,18.01918797887353,5.6939443244049525e-12,0.1592604963520488,149.40025510017165,1.80791088263472,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-660NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,660.0,624.1,3.08,,,66.0,18.03,46.6,17.02,38.8,0.007392300000000001,-0.113238,44.3,1.620583627847235,18.048890994832785,5.764395630470118e-12,0.15743267814071255,150.25736951577008,1.8970258048161648,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-665NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,665.0,628.9,3.08,,,66.0,18.07,46.8,17.06,39.0,0.007408700000000001,-0.11372399999999999,44.3,1.6281082773220326,18.088563490576814,5.836004348936938e-12,0.15552657492915192,151.39206721108684,1.9817759143054952,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-670NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,670.0,633.7,3.08,,,66.0,18.1,47.0,17.09,39.2,0.007421000000000001,-0.11421,44.3,1.6356562575987164,18.11827217398607,5.9068625812221814e-12,0.1537136656496432,152.26526160001816,2.069113413140962,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-675NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,675.0,638.6,3.08,,,66.0,18.14,47.2,17.12,39.4,0.0074374,-0.114696,44.3,1.6436163804129005,18.158702964956053,6.0206538899438635e-12,0.15180467327505373,147.23530636742524,2.21337822231236,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-680NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,680.0,643.4,3.08,,,66.0,18.18,47.4,17.16,39.6,0.0074538,-0.11518199999999999,44.3,1.6511396968872272,18.19837412068805,6.0933312260393506e-12,0.14992370533456145,148.33977707370104,2.2955513371549823,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-685NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,685.0,648.3,3.08,,,66.0,18.21,47.7,17.19,39.8,0.007466100000000001,-0.115911,44.3,1.6605085848096959,18.228582571324047,5.991723760432236e-12,0.15398206244090112,150.89479854578167,2.1392198332519436,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-690NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,690.0,653.1,3.08,,,66.0,18.25,47.9,17.23,40.1,0.0074825000000000004,-0.11639699999999999,44.3,1.6700182253205225,18.26765845486676,6.2729067515484804e-12,0.1454957864081123,150.36978745420944,2.5077224528809587,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-695NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,695.0,661.5,3.11,,,66.0,18.28,48.3,17.25,40.3,0.007494800000000001,-0.11495399999999999,43.2,1.6535368692250947,18.300439349276505,3.702859844775682e-12,0.15906402916785617,142.25944360620693,0.20790046677449361,-0.287,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-700NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,700.0,662.8,3.08,,,66.0,18.32,48.6,17.29,40.5,0.0075112,-0.11809800000000001,44.3,1.6909957037610155,18.33928765284405,5.941331568466434e-12,0.15929387507945816,151.30217340360542,2.018206342222153,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-705NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,705.0,667.7,3.08,,,66.0,18.36,48.8,17.33,40.7,0.0075276,-0.118584,44.3,1.6985179246459852,18.378961383265654,6.011796540471555e-12,0.15741396018485485,152.4213857504633,2.0986476861149055,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-710NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,710.0,672.5,3.08,,,66.0,18.4,49.0,17.36,40.9,0.007544,-0.11907,44.3,1.7064872907667579,18.41939103326506,6.124386362820613e-12,0.15552266497127057,147.57424219234366,2.2387269465942157,-0.3,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-715NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,715.0,680.9,3.11,,,66.0,18.44,49.2,17.4,41.1,0.007560400000000001,-0.117096,43.2,1.68533581711705,18.46037833131921,3.799103981505627e-12,0.15741628899223206,142.4432807060961,0.3494351275392271,-0.287,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-720NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,720.0,679.8,3.11,,,22.0,18.49,49.4,17.44,41.3,0.008043149999999999,-0.11767079999999999,45.98,1.7081017079653864,18.510062970018627,4.9992941978931655e-12,0.15351030940378685,141.4748475056028,2.506993966005199,-0.2918,N,2025.7.3,6/23/2025,4.0,bootstrapping +Trina Solar CoLtd TSM-725NEG21C20,Trina Solar CoLtd,Mono-c-Si,1,725.0,690.7,3.11,,,66.0,18.54,49.6,17.47,41.5,0.0076013999999999995,-0.118048,43.2,1.7013740452998098,18.561851846076905,3.968915554793664e-12,0.15351380822533903,130.247394051672,0.67533048752199,-0.287,N,2025.7.3,6/23/2025,4.0,bootstrapping +TSEC TS60-AMH-355 H1,TSEC,Mono-c-Si,0,355.0,329.3,1.81,,,60.0,11.25,40.3,10.51,33.8,0.00675,-0.12492999999999999,44.62,1.6005029342927473,11.261553822316523,1.2751652381140533e-10,0.15133690456068466,147.35731304459125,6.3128444004797375,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-355 H2,TSEC,Mono-c-Si,0,355.0,328.3,1.81,,,60.0,11.25,40.3,10.51,33.8,0.00675,-0.12089999999999998,45.39,1.596989514332938,11.261662941726787,1.206321188584688e-10,0.15206639175289768,146.68228489177875,9.395242375346534,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-360 H1,TSEC,Mono-c-Si,0,360.0,334.0,1.81,,,60.0,11.35,40.5,10.59,34.0,0.00681,-0.12555,44.62,1.610380117504563,11.36211290965205,1.3238889378783222e-10,0.1469933772998557,137.73526868672417,6.564160590543315,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-360 H2,TSEC,Mono-c-Si,0,360.0,333.0,1.81,,,60.0,11.34,40.5,10.59,34.0,0.006804,-0.1215,45.39,1.6060744180131945,11.35172795726364,1.237645496225454e-10,0.14800719843898696,143.11116805593852,9.553298679948691,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-365 H1,TSEC,Mono-c-Si,0,365.0,338.8,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0068579999999999995,-0.12617,44.62,1.6179238388468669,11.441160680707616,1.3269181296494588e-10,0.14344199103547403,146.9034044333392,6.518315384539478,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-365 H2,TSEC,Mono-c-Si,0,365.0,337.8,1.81,,,60.0,11.43,40.7,10.68,34.2,0.0068579999999999995,-0.1221,45.39,1.61435598082308,11.441269223900468,1.2550283456449778e-10,0.14417194624421092,146.22882574738355,9.60493406119416,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-370 H1,TSEC,Mono-c-Si,0,370.0,343.6,1.81,,,60.0,11.52,40.9,10.76,34.4,0.006912,-0.12678999999999999,44.62,1.6270390921246436,11.531209758341502,1.360931684378566e-10,0.13950516301109148,143.36611564741128,6.670422492619061,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-370 H2,TSEC,Mono-c-Si,0,370.0,342.5,1.81,,,60.0,11.52,40.9,10.77,34.4,0.006912,-0.12269999999999999,45.39,1.6226392509698968,11.530822890592058,1.2725269258186868e-10,0.1404005994865973,149.44389623430317,9.656273613444416,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-375 H1,TSEC,Mono-c-Si,0,375.0,348.4,1.81,,,60.0,11.6,41.1,10.84,34.6,0.006959999999999999,-0.12741,44.62,1.6354262532029993,11.61078610085942,1.3801664727194446e-10,0.13589617498578316,146.15065101808233,6.730193002821689,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-375 H2,TSEC,Mono-c-Si,0,375.0,347.3,1.81,,,60.0,11.6,41.1,10.84,34.6,0.006959999999999999,-0.1233,45.39,1.6317738754930706,11.610894995408005,1.3045366018442883e-10,0.13663334148482634,145.47475552944252,9.817185173678842,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-380 H1,TSEC,Mono-c-Si,0,380.0,353.1,1.81,,,60.0,11.69,41.3,10.92,34.8,0.007014,-0.12803,44.62,1.613420016707981,11.690003636236087,8.929531610416387e-11,0.1379323002427979,443452.10981899296,2.90399334886234,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-380 H2,TSEC,Mono-c-Si,0,380.0,352.1,1.81,,,60.0,11.69,41.3,10.92,34.8,0.007014,-0.12389999999999998,45.39,1.627332160045752,11.7013392196321,1.0843788062162271e-10,0.13552888158183876,139.72148896088405,8.126599051608146,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-AMH-385 H1,TSEC,Mono-c-Si,0,385.0,357.9,1.81,,,60.0,11.78,41.5,11.0,35.0,0.007068,-0.12865000000000001,44.62,1.621662322831346,11.78000350221706,9.059440328864518e-11,0.13429623628901344,451735.93242099235,2.9603027357196154,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS54-BMH-390 H1,TSEC,Mono-c-Si,0,390.0,361.1,1.94,,,54.0,13.64,36.82,12.91,30.22,0.006820000000000001,-0.106778,45.22,1.4163046222157134,13.646366433919159,6.941976948295243e-11,0.17823947116857097,381.8757154288323,6.65581895412934,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS54-BMH-395 H1,TSEC,Mono-c-Si,0,395.0,365.9,1.94,,,54.0,13.71,36.9,13.03,30.32,0.006855,-0.10701,45.22,1.4173592012120213,13.711783324347707,6.755486318614019e-11,0.1747946466213408,1343.802099823241,6.36127773744593,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS54-BMH-400 H1,TSEC,Mono-c-Si,0,400.0,370.7,1.94,,,54.0,13.78,36.98,13.15,30.42,0.00689,-0.10724199999999998,45.22,1.421602509143933,13.780002278357248,6.950089385786687e-11,0.1653179265440395,999999.9069223781,6.555015657117707,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS54-BMH-405 H1,TSEC,Mono-c-Si,0,405.0,375.4,1.94,,,54.0,13.85,37.06,13.27,30.52,0.006925000000000001,-0.107474,45.22,1.4279368812978586,13.85000389016814,7.412653364242428e-11,0.15139459280421685,539013.0856960036,7.066764167555315,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS54-BMH-410 H1,TSEC,Mono-c-Si,0,410.0,380.2,1.94,,,54.0,13.92,37.14,13.39,30.62,0.00696,-0.107706,45.22,1.4345151610777624,13.920164732190289,7.93483240691919e-11,0.13628291141320942,11516.02835760569,7.613457048937193,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-AMH-425 H2,TSEC,Mono-c-Si,0,425.0,393.0,2.16,,,72.0,11.22,48.7,10.52,40.4,0.006732,-0.1461,45.39,1.9147449201783733,11.231586819496583,9.911116953305932e-11,0.23411207616513643,226.70048163132276,7.678073626814796,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-430 H2,TSEC,Mono-c-Si,0,430.0,397.8,2.16,,,72.0,11.3,48.9,10.6,40.6,0.00678,-0.1467,45.39,1.9230181041598897,11.311181468744008,1.0040774678107677e-10,0.22973590290293583,232.171264000419,7.727937178834662,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-BMH-435 H1,TSEC,Mono-c-Si,0,435.0,402.9,2.15,,,60.0,13.38,40.75,12.93,33.71,0.006690000000000001,-0.118175,45.22,1.5796826471799024,13.380168315650431,8.377859259505214e-11,0.12917201285378496,10268.345242118261,8.431914019330659,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-AMH-435 H1,TSEC,Mono-c-Si,0,435.0,403.8,2.16,,,72.0,11.39,48.7,10.64,40.9,0.006834,-0.15097000000000002,44.62,1.8996292575350386,11.39000481755855,8.369389225384684e-11,0.18154656434631156,429239.4406007037,2.5821704671466246,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-435 H2,TSEC,Mono-c-Si,0,435.0,402.5,2.16,,,72.0,11.36,49.1,10.66,40.8,0.006815999999999999,-0.14730000000000001,45.39,1.9053596182781827,11.360007311611035,7.309021836801682e-11,0.23069711984286959,358443.13020592916,4.897088848029544,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-BMH-440 H1,TSEC,Mono-c-Si,0,440.0,407.6,2.15,,,60.0,13.45,40.9,13.01,33.86,0.006725000000000001,-0.11860999999999998,45.22,1.585913136526714,13.450082416430932,8.480372237986363e-11,0.1722744255369281,28114.526327322517,8.491992925174314,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-440 H1,TSEC,Mono-c-Si,0,440.0,408.5,2.16,,,72.0,11.46,48.9,10.71,41.1,0.006876,-0.15159,44.62,1.943952416427242,11.471030861603143,1.331671364712878e-10,0.17089002463747852,177.53821598066878,6.525914236401645,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-440 H2,TSEC,Mono-c-Si,0,440.0,407.3,2.16,,,72.0,11.45,49.2,10.73,41.0,0.006869999999999999,-0.1476,45.39,1.9106714486026002,11.450006063153767,7.510528141543853e-11,0.21708524488648592,409969.51438097726,5.060833111412438,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-BMH-445 H1,TSEC,Mono-c-Si,0,445.0,412.4,2.15,,,60.0,13.56,41.05,13.11,34.01,0.0067800000000000004,-0.11904499999999998,45.22,1.592726605395131,13.560161685428703,8.687321109081724e-11,0.12238429026566762,10263.958813442052,8.63245463294525,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-AMH-445 H1,TSEC,Mono-c-Si,0,445.0,413.3,2.16,,,72.0,11.53,49.1,10.78,41.3,0.006918,-0.15221,44.62,1.9172716040658806,11.530004528415986,8.706506530015951e-11,0.17385341730547507,442671.5676375529,2.8083731183299245,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-445 H2,TSEC,Mono-c-Si,0,445.0,412.1,2.16,,,72.0,11.52,49.4,10.8,41.2,0.006912,-0.1482,45.39,1.9480309762034813,11.531010459551402,1.0964073731328301e-10,0.20768507663572772,217.29630168512114,8.331068453109596,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-BMH-450 H1,TSEC,Mono-c-Si,0,450.0,417.2,2.15,,,60.0,13.66,41.2,13.2,34.16,0.00683,-0.11948,45.22,1.5987146496763291,13.660162278385506,8.77514042318242e-11,0.12178828230637902,10251.701403589062,8.656203934442233,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-AMH-450 H1,TSEC,Mono-c-Si,0,450.0,418.1,2.16,,,72.0,11.6,49.3,10.85,41.5,0.006959999999999999,-0.15283,44.62,1.926090946454695,11.600004403463652,8.87775085803751e-11,0.1700816712191696,448060.56183215225,2.9198969441361244,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-450 H2,TSEC,Mono-c-Si,0,450.0,416.8,2.16,,,72.0,11.58,49.6,10.87,41.4,0.006948,-0.14880000000000002,45.39,1.9554820146263503,11.590073351236672,1.0974638480357079e-10,0.20410373752027436,234.63108606468916,8.289419589104803,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-BMH-455 H1,TSEC,Mono-c-Si,0,455.0,422.0,2.15,,,60.0,13.76,41.35,13.29,34.31,0.006880000000000001,-0.11991500000000001,45.22,1.60470511066224,13.760162772215219,8.863537759852892e-11,0.12116203463482011,10242.48040146209,8.680121507002385,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-AMH-455 H1,TSEC,Mono-c-Si,0,455.0,422.9,2.16,,,72.0,11.66,49.5,10.92,41.7,0.0069960000000000005,-0.15345,44.62,1.9355854760158167,11.66000430400971,9.124231421768013e-11,0.16638203417119862,450762.3299125648,3.1047968864845896,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-455 H2,TSEC,Mono-c-Si,0,455.0,421.6,2.16,,,72.0,11.65,49.8,10.94,41.6,0.0069900000000000006,-0.1494,45.39,1.9638135212194445,11.659737512632711,1.1109118300567854e-10,0.200251397116924,239.58159808643802,8.341996030619944,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS60-BMH-460 H1,TSEC,Mono-c-Si,0,460.0,426.7,2.15,,,60.0,13.88,41.5,13.38,34.46,0.006940000000000001,-0.12035,45.22,1.593352852351961,13.880004175104327,6.774555435556329e-11,0.1635407274621793,543713.7327046198,6.273199530019611,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-460 H1,TSEC,Mono-c-Si,0,460.0,427.7,2.16,,,72.0,11.73,49.7,10.99,41.9,0.007038,-0.15407,44.62,1.9444015966438917,11.730004193037026,9.29999146014284e-11,0.1627063012396749,455186.9012559518,3.2138795390747124,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-AMH-465 H1,TSEC,Mono-c-Si,0,465.0,432.5,2.16,,,72.0,11.8,49.9,11.06,42.1,0.00708,-0.15469,44.62,1.9532165588507884,11.800004088597653,9.477535500485144e-11,0.15907733679179908,459126.3270237233,3.321962167691059,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS66-BMH-480 H1,TSEC,Mono-c-Si,0,480.0,444.7,2.35,,,66.0,13.59,44.95,12.71,37.78,0.006795,-0.130355,45.22,1.7617163073322637,13.603400412608126,1.102054522907899e-10,0.13681325298038,138.74887206615017,10.799537363503433,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS66-BMH-485 H1,TSEC,Mono-c-Si,0,485.0,449.4,2.35,,,66.0,13.67,45.1,12.79,37.93,0.006835000000000001,-0.13079,45.22,1.767820025198087,13.683024873192823,1.1126105357529728e-10,0.13436117771482667,141.01613911928655,10.830828298032168,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS66-BMH-490 H1,TSEC,Mono-c-Si,0,490.0,454.2,2.35,,,66.0,13.74,45.25,12.87,38.08,0.00687,-0.131225,45.22,1.7732505592902372,13.752174683212251,1.1125224293848404e-10,0.13214836915410813,149.13888089903926,10.780009996109282,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS66-BMH-495 H1,TSEC,Mono-c-Si,0,495.0,459.0,2.35,,,66.0,13.82,45.4,12.95,38.23,0.006910000000000001,-0.13166,45.22,1.779358737908565,13.83182145407098,1.1231500776728459e-10,0.12975445750854128,151.69086828400503,10.811682450609595,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS66-BMH-500 H1,TSEC,Mono-c-Si,0,500.0,463.8,2.35,,,66.0,13.9,45.55,13.03,38.38,0.006950000000000001,-0.132095,45.22,1.7854681158083132,13.911475154898833,1.1338293929627338e-10,0.1273897390431189,154.30880193064291,10.843284629779621,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS66-BMH-505 H1,TSEC,Mono-c-Si,0,505.0,468.5,2.35,,,66.0,13.97,45.7,13.11,38.53,0.006985000000000002,-0.13253,45.22,1.790910010069631,13.9806767617686,1.1338595574866797e-10,0.12525721113984317,163.8926959544799,10.794249894546985,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS66-BMH-510 H1,TSEC,Mono-c-Si,0,510.0,473.3,2.35,,,66.0,14.04,45.85,13.19,38.68,0.00702,-0.132965,45.22,1.7963571403858847,14.049899798710761,1.1339721773803436e-10,0.12314919603458954,174.65150503452475,10.746144628275362,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-BMH-520 H1,TSEC,Mono-c-Si,0,520.0,481.6,2.56,,,72.0,13.59,48.9,12.69,41.05,0.006795,-0.14181,45.22,1.9168547597545698,13.604835444061072,1.1049270783961763e-10,0.1531328934080942,140.27730114444032,10.828872984252923,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-BMH-525 H1,TSEC,Mono-c-Si,0,525.0,486.4,2.56,,,72.0,13.65,49.05,12.75,41.2,0.006825000000000001,-0.14224499999999998,45.22,1.9230259497149496,13.664501019971397,1.1144504054353725e-10,0.15078941697586618,141.9400549853944,10.865142772460667,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-BMH-530 H1,TSEC,Mono-c-Si,0,530.0,491.2,2.56,,,72.0,13.71,49.2,12.82,41.35,0.006855,-0.14268,45.22,1.9284090323668572,13.723650221057682,1.1133774530387957e-10,0.14859736278566976,149.24812343715146,10.813025785016173,-0.38,N,2025.7.3,6/23/2025,4.0,first_pass +TSEC TS72-BMH-535 H1,TSEC,Mono-c-Si,0,535.0,496.0,2.56,,,72.0,13.78,49.35,12.9,41.5,0.00689,-0.143115,45.22,1.933746922308831,13.792795891157805,1.112520223240331e-10,0.14632980268569518,157.5837656298942,10.756165773147409,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-BMH-540 H1,TSEC,Mono-c-Si,0,540.0,500.7,2.56,,,72.0,13.85,49.5,12.97,41.65,0.006925000000000001,-0.14354999999999998,45.22,1.9398718587800903,13.862469889564672,1.122211288303488e-10,0.14395953785017818,159.89232471587331,10.787157445320316,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-BMH-545 H1,TSEC,Mono-c-Si,0,545.0,505.5,2.56,,,72.0,13.92,49.65,13.04,41.8,0.00696,-0.143985,45.22,1.9459977341010914,13.93214955295273,1.1319442772132459e-10,0.1416145971559011,162.25084431701154,10.81806140420971,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +TSEC TS72-BMH-550 H1,TSEC,Mono-c-Si,0,550.0,510.3,2.56,,,72.0,13.98,49.8,13.12,41.95,0.0069900000000000006,-0.14442,45.22,1.9506208716227105,13.990871471001933,1.120642906013862e-10,0.1396455725623863,179.57506750946524,10.68263421130443,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +T-Solar Global TS97,T-Solar Global,Thin Film,0,97.5,90.6,1.4252040000000001,1.298,1.098,106.0,1.67,93.0,1.41,72.0,0.001336,-0.3069,44.8,3.513615870117727,1.7032035105565937,4.644681975626819e-12,7.370150305777518,370.68824530229256,-10.950755386242909,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +T-Solar Global TS102,T-Solar Global,Thin Film,0,102.5,95.3,1.4252040000000001,1.298,1.098,106.0,1.69,93.0,1.43,72.0,0.001352,-0.3069,44.8,3.5089921652021174,1.7229797816133838,4.551449033740852e-12,7.2797729065550785,373.04116840905886,-11.18736894703803,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +T-Solar Global TS370,T-Solar Global,Thin Film,0,370.0,343.6,5.710404,2.598,2.198,216.0,3.24,185.0,2.71,141.0,0.0025920000000000006,-0.6105,44.8,6.956938075728785,3.3192030736950464,7.886543038585144e-12,8.557122571936784,350.05052184726884,-11.908637774436412,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +T-Solar Global TS390,T-Solar Global,Thin Film,0,390.0,362.3,5.710404,2.598,2.198,216.0,3.24,190.0,2.74,148.0,0.0025920000000000006,-0.6270000000000001,44.8,7.200027837046502,3.3001479985786952,9.770704770315013e-12,7.364123342986199,396.68418397593445,-10.361004170350187,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +T-Solar Global TS410,T-Solar Global,Thin Film,0,410.0,381.1,5.710404,2.598,2.198,216.0,3.28,191.0,2.78,149.0,0.0026239999999999996,-0.6303000000000001,44.8,7.235133456278324,3.338927524051157,9.816354139138731e-12,7.215184566447691,401.608685565775,-10.419338217839792,-0.3,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-36-130,US Solar,Multi-c-Si,0,130.0,114.7,1.010848,1.019,0.992,36.0,8.42,21.69,7.92,16.41,0.005052,-0.078084,46.7,0.9190639705527304,8.45245924990926,4.759809049302775e-10,0.34583678223696224,999999.951915509,4.009560418688984,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-36-135,US Solar,Multi-c-Si,0,135.0,119.2,1.010848,1.019,0.992,36.0,8.48,21.9,7.98,16.92,0.005088,-0.07884,46.7,0.9385162380726451,8.493954520468602,6.236989120101484e-10,0.29416697818821896,999999.9550816037,6.2669037324773385,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-36-140,US Solar,Multi-c-Si,0,140.0,123.7,1.010848,1.019,0.992,36.0,8.53,22.15,8.03,17.43,0.005118,-0.07973999999999999,46.7,0.9587444888278004,8.530144647174621,7.894361640108497e-10,0.24883985191560248,14675.00739879943,8.27858220171185,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-36-145,US Solar,Multi-c-Si,0,145.0,128.3,1.010848,1.019,0.992,36.0,8.6,22.37,8.1,17.9,0.00516,-0.080532,46.7,0.9776890982440002,8.601284070691177,9.928276329174831e-10,0.20551237976938086,1376.4136605546717,10.243895075493606,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-36-150,US Solar,Multi-c-Si,0,150.0,132.8,1.010848,1.019,0.992,36.0,8.63,22.51,8.13,18.45,0.005178,-0.08103600000000001,46.7,0.9978455619476222,8.632182088035302,1.370956248368346e-09,0.14201697134380184,561.6676748239704,13.152063821512272,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-48-175,US Solar,Multi-c-Si,0,175.0,154.5,1.325312,1.336,0.992,48.0,8.42,29.01,7.92,22.1,0.005052,-0.104436,46.7,1.2338187493568245,8.444891173063064,5.191597989582136e-10,0.4396767889451679,999999.9670202956,4.74996185400939,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-48-180,US Solar,Multi-c-Si,0,180.0,159.0,1.325312,1.336,0.992,48.0,8.48,29.2,7.98,22.56,0.005088,-0.10511999999999999,46.7,1.25135535203142,8.493960745391172,6.237031123285393e-10,0.39222246782182896,999999.9680880794,6.266958715194018,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-48-185,US Solar,Multi-c-Si,0,185.0,163.5,1.325312,1.336,0.992,48.0,8.53,29.49,8.03,23.04,0.005118,-0.106164,46.7,1.2714226152662487,8.535878124698488,7.211197536932541e-10,0.35581973150690155,999999.9687956444,7.480698542133426,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-48-190,US Solar,Multi-c-Si,0,190.0,168.1,1.325312,1.336,0.992,48.0,8.57,29.73,8.07,23.54,0.005142,-0.107028,46.7,1.291390377084558,8.570538437285814,8.600167994852971e-10,0.3109276771228567,4948.913230253128,8.993547292474538,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-48-195,US Solar,Multi-c-Si,0,195.0,172.7,1.325312,1.336,0.992,48.0,8.6,29.92,8.1,24.07,0.00516,-0.107712,46.7,1.3118394694045028,8.601647107515529,1.0670999826392416e-09,0.2559551921406603,1336.416015188975,10.894097233543796,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-48-200,US Solar,Multi-c-Si,0,200.0,177.2,1.325312,1.336,0.992,48.0,8.63,30.12,8.13,24.6,0.005178,-0.108432,46.7,1.3323767314625476,8.632117859845438,1.307746594024798e-09,0.20279730596032133,826.3737049380172,12.71671090962342,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-54-200,US Solar,Multi-c-Si,0,200.0,176.6,1.4830400000000001,1.495,0.992,54.0,8.42,32.8,7.92,25.25,0.005052,-0.11807999999999998,46.7,1.4029185397110302,8.433821496732536,5.919576244427773e-10,0.4576236213120663,999999.9724356463,5.879157634984293,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-54-205,US Solar,Multi-c-Si,0,205.0,181.2,1.4830400000000001,1.495,0.992,54.0,8.47,33.01,7.97,25.72,0.005082000000000001,-0.118836,46.7,1.4211169248408386,8.47479583960076,6.922211241821569e-10,0.4117167559188255,999999.973074937,7.187222861826163,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-54-210,US Solar,Multi-c-Si,0,210.0,185.7,1.4830400000000001,1.495,0.992,54.0,8.5,33.23,8.0,26.25,0.0051,-0.11962799999999998,46.7,1.4418060931334313,8.500808904866181,8.310294630776457e-10,0.3595468592147186,3778.1584892879146,8.763908915383174,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-54-215,US Solar,Multi-c-Si,0,215.0,190.3,1.4830400000000001,1.495,0.992,54.0,8.52,33.44,8.02,26.81,0.005111999999999999,-0.12038399999999999,46.7,1.463652755268754,8.521903951766664,1.0161814961240068e-09,0.3023437464881,1352.9625027921966,10.539014410772621,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-54-220,US Solar,Multi-c-Si,0,220.0,194.8,1.4830400000000001,1.495,0.992,54.0,8.55,33.66,8.05,27.33,0.00513,-0.12117599999999998,46.7,1.4842411950266843,8.552324574623794,1.2055873394940598e-09,0.25247338528555685,928.6219158997501,12.05785712347082,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-220,US Solar,Multi-c-Si,0,220.0,197.6,1.6397760000000001,1.653,0.992,60.0,8.46,36.26,7.96,27.64,0.0043146,-0.1200206,45.9,1.4563573199876347,8.461085092683454,1.3015919896753738e-10,0.5657766086064154,999999.9755835012,2.0364921956594393,-0.452,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI2-54-225,US Solar,Multi-c-Si,0,225.0,199.4,1.4830400000000001,1.495,0.992,54.0,8.6,33.8,8.1,27.78,0.00516,-0.12167999999999998,46.7,1.5009507907185795,8.602322014864646,1.4204774580281692e-09,0.20277461666414157,751.0132998450268,13.513577573691977,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-225,US Solar,Multi-c-Si,0,225.0,202.2,1.6397760000000001,1.653,0.992,60.0,8.48,36.4,7.98,28.2,0.0043248,-0.12048400000000001,45.9,1.4753252361219225,8.482215012614043,1.6307634018854303e-10,0.49908384482193674,1910.7052275612414,3.893693656158151,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-225,US Solar,Multi-c-Si,0,225.0,202.1,1.6397760000000001,1.653,0.992,60.0,8.17,36.8,7.69,29.26,0.006048250999999999,-0.124752,46.5,1.5285126279012844,8.173661886715117,2.846443600612891e-10,0.40419310023081684,901.7918511314338,6.139537279732888,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-54-230,US Solar,Multi-c-Si,0,230.0,204.0,1.4830400000000001,1.495,0.992,54.0,8.66,34.02,8.16,28.19,0.005195999999999999,-0.12247200000000001,46.7,1.5177023513835073,8.662098393334126,1.5858626748851989e-09,0.1694521510494714,699.3242922139076,14.473554262029387,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-230,US Solar,Multi-c-Si,0,230.0,206.8,1.6397760000000001,1.653,0.992,60.0,8.5,36.68,8.0,28.75,0.004335,-0.12141080000000001,45.9,1.4964574346533512,8.50336233963631,1.9180546348004985e-10,0.4523372906922447,1143.510152034017,5.245203706161813,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-230,US Solar,Multi-c-Si,0,230.0,206.7,1.6397760000000001,1.653,0.992,60.0,8.25,37.34,7.8,29.49,0.006107475,-0.12658260000000002,46.5,1.5423373391358683,8.261123163780288,2.527924279496522e-10,0.4358013081523486,999999.5663756285,5.018887880521137,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-60-230,US Solar,Mono-c-Si,0,230.0,208.1,1.6397760000000001,1.653,0.992,60.0,8.5,36.2,8.0,28.8,0.00637415,-0.11728800000000002,45.6,1.4876912966278697,8.504503256054978,2.287704672994993e-10,0.3838303517464133,724.4889630269051,8.794169252016749,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-235,US Solar,Multi-c-Si,0,235.0,211.4,1.6397760000000001,1.653,0.992,60.0,8.52,36.98,8.02,29.3,0.0043452,-0.1224038,45.9,1.5178962243250576,8.52406593261838,2.227759347651711e-10,0.40848248546401794,855.9592104614187,6.5062144073999475,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-235,US Solar,Multi-c-Si,0,235.0,211.3,1.6397760000000001,1.653,0.992,60.0,8.35,37.5,7.87,29.87,0.006181505,-0.12712500000000002,46.5,1.5581270924596804,8.352555652922396,2.9375520527527606e-10,0.3949260273115244,1290.32979368238,6.219310057681245,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-235,US Solar,Mono-c-Si,0,235.0,212.8,1.6397760000000001,1.653,0.992,60.0,8.6,36.5,8.0,29.4,0.00644914,-0.11826,45.6,1.519871231814827,8.614910329214432,3.131771872351029e-10,0.32937765700383687,189.97891791680138,11.537077156218835,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-240,US Solar,Multi-c-Si,0,240.0,216.0,1.6397760000000001,1.653,0.992,60.0,8.55,37.16,8.05,29.81,0.0043605,-0.1229996,45.9,1.535927724560689,8.554456475998048,2.6433845561174063e-10,0.3551086940285755,681.2962641112626,7.958819119647454,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-240,US Solar,Multi-c-Si,0,240.0,215.9,1.6397760000000001,1.653,0.992,60.0,8.48,37.82,7.99,30.04,0.006277744,-0.1282098,46.5,1.569112965308061,8.48270683922489,2.8793616079446753e-10,0.4047762012422923,1268.086020979646,5.914764301145717,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-240,US Solar,Mono-c-Si,0,240.0,217.4,1.6397760000000001,1.653,0.992,60.0,8.6,36.8,8.1,29.7,0.00644914,-0.119232,45.6,1.5241726191431932,8.604378951580925,2.793045416794327e-10,0.32406006124281433,636.43486485192,10.465196711266637,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-245,US Solar,Multi-c-Si,0,245.0,220.6,1.6397760000000001,1.653,0.992,60.0,8.58,37.4,8.08,30.32,0.0043758,-0.123794,45.9,1.5549734024117108,8.584489725990034,3.054342445727736e-10,0.3098299437335797,592.0944149216498,9.196930520455401,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-245,US Solar,Multi-c-Si,0,245.0,220.5,1.6397760000000001,1.653,0.992,60.0,8.61,38.0,8.12,30.19,0.006373983,-0.12882000000000002,46.5,1.5760477127980475,8.61182393962444,2.902868450535863e-10,0.3995035048726714,1885.879009035996,5.851088562341241,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-245,US Solar,Mono-c-Si,0,245.0,222.0,1.6397760000000001,1.653,0.992,60.0,8.7,37.1,8.1,30.3,0.0065241299999999995,-0.120204,45.6,1.5565244982669681,8.71246271932672,3.7909716429709195e-10,0.2702542588585858,188.65965307996635,13.174506747050728,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-250,US Solar,Multi-c-Si,0,250.0,225.3,1.6397760000000001,1.653,0.992,60.0,8.61,37.65,8.11,30.83,0.004391099999999999,-0.12462150000000001,45.9,1.5741532876158044,8.61430745709777,3.5022594720328094e-10,0.2662234276998279,532.1432584545946,10.3813508475736,-0.452,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-250,US Solar,Multi-c-Si,0,250.0,225.2,1.6397760000000001,1.653,0.992,60.0,8.64,38.12,8.14,30.71,0.006396192,-0.1292268,46.5,1.5946420378962067,8.643605536194697,3.568532844759955e-10,0.33770105395642996,809.2384776920817,7.614317219782691,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-250,US Solar,Mono-c-Si,0,250.0,226.7,1.6397760000000001,1.653,0.992,60.0,8.7,37.4,8.2,30.6,0.0065241299999999995,-0.121176,45.6,1.5605170532569754,8.703980570874341,3.3729746415534876e-10,0.2659089551653577,581.1750751856598,12.06438613139859,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-60-255,US Solar,Multi-c-Si,0,255.0,226.2,1.6397760000000001,1.653,0.992,60.0,8.66,37.9,8.16,31.25,0.005195999999999999,-0.13644,46.7,1.685832563510911,8.662117501057217,1.4853876485149641e-09,0.2113077493547877,864.1919585352726,13.862643954494139,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-255,US Solar,Multi-c-Si,0,255.0,229.8,1.6397760000000001,1.653,0.992,60.0,8.66,38.2,8.16,31.25,0.006410997999999999,-0.12949800000000003,46.5,1.6120762497607393,8.6637305290337,4.4006727144763747e-10,0.2688719997938197,624.156088020197,9.442969749554285,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-255,US Solar,Mono-c-Si,0,255.0,231.4,1.6397760000000001,1.653,0.992,60.0,8.8,37.9,8.2,31.1,0.006599120000000001,-0.122796,45.6,1.5936912551727582,8.81132244844361,4.0487632856096716e-10,0.25197330626571524,195.83797142714687,13.673526631057422,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-260,US Solar,Multi-c-Si,0,260.0,234.4,1.6397760000000001,1.653,0.992,60.0,8.7,38.28,8.2,31.71,0.006440609999999999,-0.12976920000000003,46.5,1.6268959159161476,8.703373957703175,5.217387582470234e-10,0.21159005485297644,545.6008157314199,10.926983115523965,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-260,US Solar,Mono-c-Si,0,260.0,236.0,1.6397760000000001,1.653,0.992,60.0,8.8,38.2,8.3,31.4,0.006599120000000001,-0.12376800000000003,45.6,1.597508716636231,8.803537363526575,3.6028088516954554e-10,0.24799472650081464,616.9437167743549,12.559620388646511,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-265,US Solar,Multi-c-Si,0,265.0,234.1,1.94432,1.96,0.992,72.0,8.05,43.5,7.47,35.48,0.00483,-0.1566,46.7,1.939047251217845,8.060944416916163,1.4237433562161667e-09,0.3184372851285738,234.22180297713808,14.199354045894495,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-265,US Solar,Multi-c-Si,0,265.0,239.1,1.6397760000000001,1.653,0.992,60.0,8.73,38.4,8.23,32.2,0.006462819,-0.13017600000000001,46.5,1.6432916932710466,8.732792396813355,6.148055014121576e-10,0.15580600219410184,487.1036875562398,12.387318652883184,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-265,US Solar,Mono-c-Si,0,265.0,240.7,1.6397760000000001,1.653,0.992,60.0,8.9,38.5,8.3,32.0,0.0066741100000000005,-0.12474,45.6,1.6301339298072552,8.908888524931962,4.820492175904912e-10,0.19542020772435142,195.6725133000472,15.19074806111262,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-270,US Solar,Multi-c-Si,0,270.0,238.6,1.94432,1.96,0.992,72.0,8.09,43.85,7.59,35.55,0.004854,-0.15786,46.7,1.9355899698582588,8.094541819320861,1.1633126705845223e-09,0.3554629217034769,633.1598311234839,12.248972816336597,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-60-270,US Solar,Multi-c-Si,0,270.0,243.7,1.6397760000000001,1.653,0.992,60.0,8.8,38.6,8.32,32.46,0.00651464,-0.13085400000000003,46.5,1.6519165071498585,8.80165778692079,6.22269193236766e-10,0.14310194706140572,759.625775034384,12.414743097311032,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-270,US Solar,Mono-c-Si,0,270.0,245.3,1.6397760000000001,1.653,0.992,60.0,8.9,38.8,8.4,32.2,0.0066741100000000005,-0.125712,45.6,1.6308122735547514,8.90303569253132,4.1090274998977403e-10,0.2062874917999665,604.7908922398233,13.662735324919586,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-275,US Solar,Multi-c-Si,0,275.0,243.2,1.94432,1.96,0.992,72.0,8.2,44.0,7.7,35.7,0.004919999999999999,-0.15839999999999999,46.7,1.942189269203606,8.204001342748503,1.1799647606813317e-09,0.3476395104905964,712.4225472450066,12.252566749087405,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-60-275,US Solar,Mono-c-Si,0,275.0,250.0,1.6397760000000001,1.653,0.992,60.0,9.0,39.1,8.4,32.8,0.0067491,-0.12668400000000002,45.6,1.663554183423682,9.00699861010018,5.462141092194915e-10,0.15431234230911994,198.44100510299563,16.26062281334929,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-280,US Solar,Multi-c-Si,0,280.0,247.7,1.94432,1.96,0.992,72.0,8.31,44.15,7.81,35.85,0.004986,-0.15894,46.7,1.9488069750423094,8.313475015647777,1.1968641317375317e-09,0.34002862760825364,813.1304300786293,12.257943563914896,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-280,US Solar,Multi-c-Si,0,280.0,251.8,1.94432,1.96,0.992,72.0,8.33,44.15,7.83,35.78,0.0061666989999999994,-0.1496685,46.5,1.8554886472986991,8.335331099985076,3.8303909869322134e-10,0.37354854440954327,583.6807330699555,8.564698957073642,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-285,US Solar,Multi-c-Si,0,285.0,252.3,1.94432,1.96,0.992,72.0,8.41,44.32,7.91,36.02,0.005046,-0.159552,46.7,1.9565271090259568,8.413011296119583,1.2152811612855127e-09,0.332592402181589,928.8710167156813,12.285753894065127,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-285,US Solar,Multi-c-Si,0,285.0,256.4,1.94432,1.96,0.992,72.0,8.41,44.32,7.91,36.02,0.006225923,-0.1502448,46.5,1.8650991423941972,8.414908133902399,3.9923406925023327e-10,0.3562195584002591,610.3760648276161,8.844369902383427,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-72-285,US Solar,Mono-c-Si,0,285.0,258.2,1.94432,1.96,0.992,72.0,8.6,44.1,8.0,35.7,0.00644914,-0.142884,45.6,1.8416558502136393,8.614234850810233,3.3546875933375367e-10,0.3716181656235093,224.51352801382865,12.162554023860027,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-290,US Solar,Multi-c-Si,0,290.0,256.9,1.94432,1.96,0.992,72.0,8.52,44.46,8.02,36.16,0.005111999999999999,-0.160056,46.7,1.9626749205862477,8.522511456538709,1.2318099115641654e-09,0.3255776184408686,1104.5086588852405,12.287762129269284,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-290,US Solar,Multi-c-Si,0,290.0,261.0,1.94432,1.96,0.992,72.0,8.52,44.46,8.02,36.16,0.006307356,-0.1507194,46.5,1.870964850326801,8.524377090480394,4.046824917364473e-10,0.34896162193645136,679.2535141924103,8.846763813208137,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-72-290,US Solar,Mono-c-Si,0,290.0,262.8,1.94432,1.96,0.992,72.0,8.6,44.4,8.0,36.3,0.00644914,-0.143856,45.6,1.8647841867656856,8.612731480518297,3.839491331546145e-10,0.32146430555301553,217.14625469754083,13.401066976631972,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-295,US Solar,Multi-c-Si,0,295.0,261.4,1.94432,1.96,0.992,72.0,8.58,44.68,8.1,36.38,0.005148,-0.16084800000000002,46.7,1.970566791482875,8.5806135469093,1.218870969161092e-09,0.319337266706757,4465.722350835824,12.11708076540837,-0.5,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-295,US Solar,Multi-c-Si,0,295.0,265.7,1.94432,1.96,0.992,72.0,8.58,44.68,8.08,36.38,0.006351774,-0.15146520000000002,46.5,1.881014662737834,8.584093975788464,4.1178949939320453e-10,0.3422884603050181,717.3555129193574,8.93741071694078,-0.4411,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-72-295,US Solar,Mono-c-Si,0,295.0,267.5,1.94432,1.96,0.992,72.0,8.7,44.7,8.1,36.5,0.0065241299999999995,-0.144828,45.6,1.8751740831566663,8.712491849477914,3.7810833750870327e-10,0.3266364772158893,227.48734375455703,13.150458490208049,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-300,US Solar,Multi-c-Si,0,300.0,266.0,1.94432,1.96,0.992,72.0,8.63,44.82,8.21,36.52,0.005178,-0.161352,46.7,1.9830087862760277,8.630002426821527,1.3184905662450375e-09,0.2808413941696599,999999.9745812472,12.779468886072612,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI3-72-300,US Solar,Multi-c-Si,0,300.0,270.3,1.94432,1.96,0.992,72.0,8.62,44.75,8.23,36.45,0.006381386,-0.15170250000000002,46.5,1.8858579043469679,8.620002579702545,4.2660049036359604e-10,0.29912457395688047,999999.626282473,9.188757000516231,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-300,US Solar,Mono-c-Si,0,300.0,272.1,1.94432,1.96,0.992,72.0,8.7,45.0,8.1,37.1,0.0065241299999999995,-0.1458,45.6,1.8982240800401302,8.71093493347107,4.307501320966823e-10,0.2771867338251107,220.53401915289814,14.357197059027934,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI2-72-305,US Solar,Multi-c-Si,0,305.0,270.6,1.94432,1.96,0.992,72.0,8.66,44.96,8.27,36.85,0.005195999999999999,-0.161856,46.7,1.9986960673258722,8.660002005983205,1.4730128111957795e-09,0.23134433184302872,999999.7262457703,13.76975579200101,-0.5,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMI3-72-305,US Solar,Multi-c-Si,0,305.0,274.9,1.94432,1.96,0.992,72.0,8.68,44.83,8.35,36.53,0.006425804,-0.1519737,46.5,1.897236764221274,8.680183465877597,4.746244711485332e-10,0.24904897377534088,11782.882787809422,10.076827948408193,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-305,US Solar,Mono-c-Si,0,305.0,276.8,1.94432,1.96,0.992,72.0,8.8,45.4,8.2,37.2,0.006599120000000001,-0.147096,45.6,1.9074651675672125,8.811544444096878,3.969428338439765e-10,0.3096451312280449,236.03366516251896,13.490613378121346,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-310,US Solar,Multi-c-Si,0,310.0,279.6,1.94432,1.96,0.992,72.0,8.7,45.18,8.31,37.3,0.006440609999999999,-0.1531602,46.5,1.9166898568777233,8.70000202009113,5.039366015774673e-10,0.2320861371462793,999999.8267059064,10.591371401801801,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-310,US Solar,Mono-c-Si,0,310.0,281.4,1.94432,1.96,0.992,72.0,8.8,45.7,8.2,37.9,0.006599120000000001,-0.148068,45.6,1.9333973124194306,8.809576011540477,4.671003801546245e-10,0.2464940080479665,226.5188888387166,15.004154462177734,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-315,US Solar,Multi-c-Si,0,315.0,284.2,1.94432,1.96,0.992,72.0,8.72,45.32,8.38,37.58,0.006455416000000001,-0.15363480000000002,46.5,1.9331034745642663,8.720125777384238,5.736704714282562e-10,0.17316717422808328,12005.543790136877,11.741318174052711,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-315,US Solar,Mono-c-Si,0,315.0,286.1,1.94432,1.96,0.992,72.0,8.9,46.0,8.3,38.0,0.0066741100000000005,-0.14904,45.6,1.9408653436277987,8.909905318397183,4.439129932656708e-10,0.26660805970794504,239.54928965137273,14.420370698450357,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-320,US Solar,Multi-c-Si,0,320.0,288.8,1.94432,1.96,0.992,72.0,8.76,45.5,8.42,38.0,0.0064850279999999995,-0.15424500000000002,46.5,1.9469197918211354,8.760001562228103,6.207706692755007e-10,0.13945148693373277,780374.6766010969,12.416482601461444,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-320,US Solar,Mono-c-Si,0,320.0,290.8,1.94432,1.96,0.992,72.0,8.9,46.3,8.3,38.6,0.0066741100000000005,-0.150012,45.6,1.9637983907594179,8.908357779811437,5.020292257865514e-10,0.21846433187258998,232.63747012731127,15.572367491814127,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-325,US Solar,Multi-c-Si,0,325.0,293.5,1.94432,1.96,0.992,72.0,8.78,45.65,8.48,38.32,0.0064998339999999995,-0.15475350000000002,46.5,1.9635355660933154,8.780058400283744,7.021831823267926e-10,0.08020739424628558,12058.581117101043,13.527991481205763,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-325,US Solar,Mono-c-Si,0,325.0,295.4,1.94432,1.96,0.992,72.0,9.0,46.6,8.4,38.7,0.0067491,-0.150984,45.6,1.9712841042568943,9.008732864500507,4.77491516326465e-10,0.23865405694253775,245.9544338594871,14.994305075421789,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMI3-72-330,US Solar,Multi-c-Si,0,330.0,298.2,1.94432,1.96,0.992,72.0,8.82,45.8,8.54,38.62,0.0065294459999999995,-0.155262,46.5,1.9760160336568393,8.820000374552084,7.575490247351829e-10,0.042448125646069555,999999.9676426401,14.186934869326276,-0.4411,N,2025.7.3,6/23/2025,2.0,first_pass +US Solar USS-QCMO3-72-330,US Solar,Mono-c-Si,0,330.0,300.1,1.94432,1.96,0.992,72.0,9.0,46.9,8.4,39.3,0.0067491,-0.151956,45.6,1.9941630633492413,9.007197553457527,5.382802922308501e-10,0.19113440831331865,238.9992462213748,16.12211800895707,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +US Solar USS-QCMO3-72-335,US Solar,Mono-c-Si,0,335.0,304.8,1.94432,1.96,0.992,72.0,9.1,47.2,8.5,39.5,0.00682409,-0.152928,45.6,2.004562542188957,9.107190751722202,5.299885807387185e-10,0.1975795083752177,250.03974041062892,15.868322640073682,-0.4319,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE435M-72HB,United Energy Co Ltd,Mono-c-Si,0,435.0,404.3,2.17,,,72.0,11.23,49.4,10.69,40.7,0.005615000000000001,-0.13436800000000002,46.2,1.8213825736598337,11.231866018831452,1.863415868267932e-11,0.28967539041326107,1743.3129509855075,3.8863792220727067,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE440M-72HB,United Energy Co Ltd,Mono-c-Si,0,440.0,409.1,2.17,,,72.0,11.3,49.6,10.76,40.9,0.0056500000000000005,-0.13491200000000003,46.2,1.8292840589439736,11.301631897095204,1.8902821576758032e-11,0.28529101414155994,1975.485249268253,3.9537297081495404,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE445M-72HB,United Energy Co Ltd,Mono-c-Si,0,445.0,413.9,2.17,,,72.0,11.37,49.8,10.83,41.1,0.005685,-0.13545600000000002,46.2,1.837185778875411,11.371403942198173,1.91733289304474e-11,0.28096363955783016,2275.4190242760724,4.020561597725543,-0.345,N,2025.7.3,6/23/2025,4.0,bootstrapping +United Energy Co Ltd UE450M-72HB,United Energy Co Ltd,Mono-c-Si,0,450.0,418.6,2.17,,,72.0,11.44,50.0,10.9,41.3,0.00572,-0.136,46.2,1.8450877281213045,11.44118205247124,1.9445674383110577e-11,0.27669216379316863,2677.8491068855983,4.086880320968866,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE455M-72HB,United Energy Co Ltd,Mono-c-Si,0,455.0,423.4,2.17,,,72.0,11.51,50.2,10.96,41.5,0.005755,-0.136544,46.2,1.8537861064088443,11.511783683050167,1.9929346401350253e-11,0.2724297250635558,1757.972795015433,4.245901956842951,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE460M-72HB,United Energy Co Ltd,Mono-c-Si,0,460.0,428.2,2.17,,,72.0,11.58,50.4,11.03,41.7,0.00579,-0.13708800000000002,46.2,1.8616873141104304,11.581562007007062,2.0207008762558357e-11,0.26826371971884133,1988.7836801830917,4.310714661550935,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE465M-72HB,United Energy Co Ltd,Mono-c-Si,0,465.0,433.0,2.17,,,72.0,11.65,50.6,11.1,41.9,0.005825,-0.137632,46.2,1.8695891575119614,11.651346227640957,2.0486609851854272e-11,0.26415047360861177,2285.9085043942905,4.375083926486335,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE470M-72HB,United Energy Co Ltd,Mono-c-Si,0,470.0,437.8,2.17,,,72.0,11.72,50.8,11.17,42.1,0.005860000000000001,-0.13817600000000002,46.2,1.8774902925650403,11.721136272006557,2.0767745382007187e-11,0.26008925232734026,2682.6730276794624,4.438853362275635,-0.345,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE520M-72HB,United Energy Co Ltd,Mono-c-Si,0,520.0,488.3,2.58,,,72.0,13.54,49.2,12.84,40.5,0.0073116,-0.12792,45.8,1.7372996936147656,13.549033069850978,6.7396927624527545e-12,0.2559409456627924,383.6392807707354,-1.4916476024150949,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE525M-72HB,United Energy Co Ltd,Mono-c-Si,0,525.0,493.1,2.58,,,72.0,13.61,49.3,12.94,40.6,0.0073494,-0.12818000000000002,45.8,1.7438662163413259,13.610007248620775,7.180015565118307e-12,0.2526479301308021,474374.2977813291,-1.0512231186599341,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE535M-72HB,United Energy Co Ltd,Mono-c-Si,0,535.0,502.8,2.58,,,72.0,13.75,49.5,13.13,40.8,0.007425,-0.1287,45.8,1.743513450578816,13.750884334758483,6.425314596117646e-12,0.24892973933409712,3870.461824429311,-2.0292922009472463,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE540M-72HB,United Energy Co Ltd,Mono-c-Si,0,540.0,507.6,2.58,,,72.0,13.82,49.6,13.22,40.9,0.007462800000000001,-0.12896000000000002,45.8,1.7403983147536293,13.820006480688118,5.844984006999396e-12,0.2465556833732262,525780.315212462,3.6552184762481614,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE545M-72HB,United Energy Co Ltd,Mono-c-Si,0,545.0,512.4,2.58,,,72.0,13.89,49.7,13.31,41.0,0.0075006,-0.12922000000000003,45.8,1.752600522933383,13.89000327040714,6.714887534321201e-12,0.2354473933449123,999998.1221807082,-1.758545847979298,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +United Energy Co Ltd UE550M-72HB,United Energy Co Ltd,Mono-c-Si,0,550.0,517.2,2.58,,,72.0,13.96,49.8,13.41,41.0,0.0075384,-0.12948,45.8,1.7559544462815133,13.96000667039889,6.72993857919434e-12,0.24956779565598644,522305.8671179885,-1.7810350280777945,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE555M-72HB,United Energy Co Ltd,Mono-c-Si,0,555.0,522.0,2.58,,,72.0,14.03,49.9,13.5,41.1,0.0075762,-0.12974,45.8,1.7615716055941353,14.030003497316233,6.995292150148475e-12,0.22435647930835378,900047.9158391353,-1.508953999570958,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +United Energy Co Ltd UE560M-72HB,United Energy Co Ltd,Mono-c-Si,0,560.0,526.8,2.58,,,72.0,14.1,50.0,13.59,41.2,0.007613999999999999,-0.13,45.8,1.7657726803811873,14.100006320298125,7.106328663053569e-12,0.2444023770971338,545242.7799148203,-1.4088815231994762,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Energy Co Ltd UE565M-72HB,United Energy Co Ltd,Mono-c-Si,0,565.0,531.7,2.58,,,72.0,14.17,50.1,13.68,41.3,0.007651799999999999,-0.13026000000000001,45.8,1.771764958620162,14.170003258872333,7.427995837273129e-12,0.2075130949881013,902302.4771396016,-1.1029525476052142,-0.304,N,2025.7.3,6/23/2025,2.0,first_pass +United Energy Co Ltd UE570M-72HB,United Energy Co Ltd,Mono-c-Si,0,570.0,536.5,2.58,,,72.0,14.24,50.2,13.77,41.4,0.0076895999999999996,-0.13052,45.8,1.7757855711433936,14.240165614652458,7.5212882733505e-12,0.23934193501142248,20579.280789545748,-1.0410512056158225,-0.304,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P120A1F,United Renewable Energy Co Ltd,Multi-c-Si,0,120.0,106.9,0.9828720000000001,1.496,0.657,36.0,7.49,21.6,6.93,17.33,0.00160286,-0.07125840000000001,46.1,0.894542713863253,7.507942721627209,2.377082786700595e-10,0.23690509871578158,98.89354433589318,8.969778810762824,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P125A1F,United Renewable Energy Co Ltd,Multi-c-Si,0,125.0,111.5,0.9828720000000001,1.496,0.657,36.0,7.89,21.58,7.28,17.19,0.00168846,-0.07119242,46.1,0.8913164946066807,7.912587865999474,2.3408472486467934e-10,0.24479246531030283,85.50664795447207,8.389538129851214,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P130A1F,United Renewable Energy Co Ltd,Multi-c-Si,0,130.0,116.0,0.9828720000000001,1.496,0.657,36.0,7.93,21.66,7.45,17.54,0.0016970199999999998,-0.07145634000000001,46.1,0.8945145715964087,7.936195939930058,2.3923110564451486e-10,0.19898460289731557,254.67454625360975,8.47028031975492,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P135A1F,United Renewable Energy Co Ltd,Multi-c-Si,0,135.0,120.6,0.9828720000000001,1.496,0.657,36.0,8.26,22.1,7.64,17.68,0.0017676399999999998,-0.07290790000000001,46.1,0.9138760516144475,8.28058971320465,2.527936963871533e-10,0.22771087239315652,91.35105233175476,8.652539716967382,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P140A1F,United Renewable Energy Co Ltd,Multi-c-Si,0,140.0,125.2,0.9828720000000001,1.496,0.657,36.0,8.57,22.25,7.89,17.75,0.0018339799999999998,-0.07340275,46.1,0.9208728977549553,8.596345682188572,2.6641198248641765e-10,0.22841478507540725,74.3011640444459,8.805535915522636,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P190A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,190.0,167.8,1.4069699999999998,1.458,0.965,54.0,7.87,32.85,7.56,25.18,0.014402100000000001,-0.1363275,43.9,1.6216822441154595,8.121296059070108,1.2948873859338686e-08,0.4413749826580069,999999.9692987367,17.38327700244513,-0.572,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P195A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,195.0,172.4,1.4069699999999998,1.458,0.965,54.0,8.11,32.94,7.63,25.59,0.015408999999999999,-0.13834799999999997,43.9,1.6508306096145067,8.18535927361424,1.7672631299431593e-08,0.38117738595892064,999999.5190105189,18.886773186595345,-0.572,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P200A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,200.0,176.9,1.4069699999999998,1.458,0.965,54.0,8.31,33.03,7.85,25.5,0.015789,-0.13872600000000002,43.9,1.6631048575048242,8.310002967438606,1.9693297803634925e-08,0.34610301023278667,999999.9600719666,19.82327340929346,-0.572,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P205A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,205.0,181.5,1.4069699999999998,1.458,0.965,54.0,8.61,33.58,7.93,25.87,0.016359,-0.141036,43.9,1.6864585714190743,8.623086793126111,1.913178180438868e-08,0.4026112167461379,264.8866618843881,19.181215786400244,-0.572,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P210A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,210.0,186.1,1.4069699999999998,1.458,0.965,54.0,8.65,33.61,8.02,26.19,0.016435,-0.141162,43.9,1.6943236219774949,8.65605416636612,2.0843114253835773e-08,0.3553534944131982,507.72672792204844,20.005321030295054,-0.572,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P215A3F,United Renewable Energy Co Ltd,Mono-c-Si,0,215.0,192.0,1.611081,1.629,0.989,60.0,7.96,36.39,7.41,29.02,0.00170344,-0.12005061000000002,46.1,1.496952528338198,7.974579306221921,2.1636757574564938e-10,0.4038414817331339,220.48913072101288,7.597280855584417,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P215A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,215.0,192.5,1.464709,1.481,0.989,54.0,8.71,33.69,8.08,26.61,0.0018639400000000001,-0.11114331,46.1,1.3807830172950333,8.730645674601995,2.1577885125664764e-10,0.3793483346657465,160.03954349202803,6.8088759891571025,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P220A3F,United Renewable Energy Co Ltd,Mono-c-Si,0,220.0,196.5,1.611081,1.629,0.989,60.0,8.1,36.57,7.56,29.11,0.0017334,-0.12064443000000002,46.1,1.5007425713408113,8.112542630618726,2.083466758052853e-10,0.4071621534335231,262.9443503625407,7.110895730342556,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P220A5F,United Renewable Energy Co Ltd,Multi-c-Si,0,220.0,197.1,1.464709,1.481,0.989,54.0,8.75,33.75,8.24,26.71,0.0018725,-0.11134125000000002,46.1,1.3742219331269974,8.754047771779149,1.879829805235945e-10,0.3698415846740825,799.4806688287782,5.538408819625509,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P225A3F,United Renewable Energy Co Ltd,Multi-c-Si,0,225.0,201.1,1.611081,1.629,0.989,60.0,8.21,36.75,7.71,29.19,0.00175694,-0.12123825,46.1,1.5015318167957359,8.216765823480555,1.9118308823745538e-10,0.41319089151037597,501.38731009804314,6.234959901349466,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P230A3F,United Renewable Energy Co Ltd,Multi-c-Si,0,230.0,205.7,1.611081,1.629,0.989,60.0,8.32,36.87,7.85,29.3,0.00178048,-0.12163413000000001,46.1,1.503298305003124,8.322205599198202,1.8511653372451063e-10,0.4066223495496443,1533.8680613538309,5.829293542644299,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P230B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,230.0,205.9,1.6335,1.65,0.99,60.0,8.26,36.3,7.79,29.53,0.00413,-0.12705,46.3,1.5260485302446274,8.262927333471724,3.8396457335445264e-10,0.29310157819444616,827.039451185386,5.484703706919396,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P230B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,230.0,205.9,1.6335,1.65,0.99,60.0,8.26,36.3,7.79,29.53,0.00413,-0.12705,46.3,1.5260485302446274,8.262927333471724,3.8396457335445264e-10,0.29310157819444616,827.039451185386,5.484703706919396,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M235B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,235.0,208.7,1.6335,1.65,0.99,60.0,8.42,37.08,7.88,29.84,0.005894,-0.14090399999999997,46.5,1.6349425572552732,8.426583250257504,1.178439284565533e-09,0.32115955685999326,410.76450195139887,5.957688533699543,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M235B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,235.0,208.7,1.6335,1.65,0.99,60.0,8.42,37.08,7.88,29.84,0.005894,-0.14090399999999997,46.5,1.6349425572552732,8.426583250257504,1.178439284565533e-09,0.32115955685999326,410.76450195139887,5.957688533699543,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P235A3F,United Renewable Energy Co Ltd,Multi-c-Si,0,235.0,210.3,1.611081,1.629,0.989,60.0,8.45,37.06,8.01,29.34,0.0018082999999999997,-0.12226094000000003,46.1,1.50846637677594,8.45000344296162,1.8076265422087072e-10,0.40726169202294343,999999.8988028691,5.487582646356897,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P235B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,235.0,210.5,1.6335,1.65,0.99,60.0,8.35,36.33,7.91,29.71,0.004175000000000001,-0.127155,46.3,1.5283356572788216,8.3501607118346,3.962449086906483e-10,0.26740448117249943,13893.4736571162,5.646242641746725,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P235B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,235.0,210.5,1.6335,1.65,0.99,60.0,8.35,36.33,7.91,29.71,0.004175000000000001,-0.127155,46.3,1.5283356572788216,8.3501607118346,3.962449086906483e-10,0.26740448117249943,13893.4736571162,5.646242641746725,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M240B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,240.0,213.3,1.6335,1.65,0.99,60.0,8.47,37.35,7.96,30.16,0.005929000000000001,-0.14193,46.5,1.646451889886091,8.473406771205468,1.1844203779143002e-09,0.30657159981964266,762.2070152991142,5.938177653449323,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M240B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,240.0,213.3,1.6335,1.65,0.99,60.0,8.47,37.35,7.96,30.16,0.005929000000000001,-0.14193,46.5,1.646451889886091,8.473406771205468,1.1844203779143002e-09,0.30657159981964266,762.2070152991142,5.938177653449323,-0.49,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P240A3F,United Renewable Energy Co Ltd,Multi-c-Si,0,240.0,214.9,1.611081,1.629,0.989,60.0,8.55,37.18,8.16,29.42,0.0018297,-0.12265682000000001,46.1,1.517637857840352,8.550003222538498,1.9604618867642271e-10,0.376730980154213,999985.2889046718,6.076002649109771,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P240B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,240.0,215.1,1.6335,1.65,0.99,60.0,8.49,36.96,7.97,30.2,0.0042450000000000005,-0.12936,46.3,1.5616585024158474,8.496135562111728,4.4220900922562644e-10,0.27019101757296327,373.8732084093963,6.476594691639564,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P240B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,240.0,215.1,1.6335,1.65,0.99,60.0,8.49,36.96,7.97,30.2,0.0042450000000000005,-0.12936,46.3,1.5616585024158474,8.496135562111728,4.4220900922562644e-10,0.27019101757296327,373.8732084093963,6.476594691639564,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M245B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,245.0,217.9,1.6335,1.65,0.99,60.0,8.52,37.62,8.07,30.38,0.0059640000000000006,-0.142956,46.5,1.6539923088843387,8.548289522731004,1.1320452311426777e-09,0.3061941603424139,999999.6240303019,5.4576392889269485,-0.49,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M245B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,245.0,217.9,1.6335,1.65,0.99,60.0,8.52,37.62,8.07,30.38,0.0059640000000000006,-0.142956,46.5,1.6539923088843387,8.548289522731004,1.1320452311426777e-09,0.3061941603424139,999999.6240303019,5.4576392889269485,-0.49,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P245A3F,United Renewable Energy Co Ltd,Multi-c-Si,0,245.0,219.5,1.611081,1.629,0.989,60.0,8.67,37.31,8.29,29.56,0.0018553799999999998,-0.12308569000000003,46.1,1.5251006982383644,8.670003412163092,2.0580460813354906e-10,0.35949299163847154,913107.1882752307,6.3709499014396025,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P245B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,245.0,219.8,1.6335,1.65,0.99,60.0,8.54,37.1,8.02,30.65,0.0042699999999999995,-0.12985,46.3,1.5773262435425528,8.54532968098971,5.145112404980551e-10,0.22034501076364396,353.06929458039104,7.738834465124245,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P245B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,245.0,219.8,1.6335,1.65,0.99,60.0,8.54,37.1,8.02,30.65,0.0042699999999999995,-0.12985,46.3,1.5773262435425528,8.54532968098971,5.145112404980551e-10,0.22034501076364396,353.06929458039104,7.738834465124245,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M250B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,250.0,222.4,1.6335,1.65,0.99,60.0,8.58,37.85,8.17,30.6,0.006006000000000001,-0.14383,46.5,1.6725243298915624,8.580002275996312,1.2740904901282777e-09,0.264832620228425,999991.0470305016,6.443363987414077,-0.49,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M250B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,250.0,222.4,1.6335,1.65,0.99,60.0,8.58,37.85,8.17,30.6,0.006006000000000001,-0.14383,46.5,1.6725243298915624,8.580002275996312,1.2740904901282777e-09,0.264832620228425,999991.0470305016,6.443363987414077,-0.49,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P250B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,250.0,224.4,1.6335,1.65,0.99,60.0,8.59,37.24,8.08,31.05,0.004295,-0.13033999999999998,46.3,1.5903502722869618,8.593971865075416,5.7512434935587e-10,0.17877637286823433,386.6418862246095,8.659139748054027,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P250B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,250.0,224.4,1.6335,1.65,0.99,60.0,8.59,37.24,8.08,31.05,0.004295,-0.13033999999999998,46.3,1.5903502722869618,8.593971865075416,5.7512434935587e-10,0.17877637286823433,386.6418862246095,8.659139748054027,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M255B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,255.0,227.0,1.6335,1.65,0.99,60.0,8.63,38.3,8.28,30.82,0.006041000000000002,-0.14554,46.5,1.6955183136451373,8.630193086756194,1.3353126516745833e-09,0.2455043238167537,10972.988447702557,6.801831798102993,-0.49,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M255B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,255.0,227.0,1.6335,1.65,0.99,60.0,8.63,38.3,8.28,30.82,0.006041000000000002,-0.14554,46.5,1.6955183136451373,8.630193086756194,1.3353126516745833e-09,0.2455043238167537,10972.988447702557,6.801831798102993,-0.49,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P255B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,255.0,231.8,1.6268799999999999,1.64,0.992,60.0,8.52,39.03,8.17,31.29,0.0059640000000000006,-0.136605,43.2,1.6979000819591648,8.520216978592586,8.852156404777221e-10,0.2823566672805806,11087.312322445921,12.335911963690503,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P255B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,255.0,231.8,1.6268799999999999,1.64,0.992,60.0,8.52,39.03,8.17,31.29,0.0059640000000000006,-0.136605,43.2,1.6979000819591648,8.520216978592586,8.852156404777221e-10,0.2823566672805806,11087.312322445921,12.335911963690503,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M260B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,260.0,234.5,1.6268799999999999,1.64,0.992,60.0,8.79,38.21,8.45,30.81,0.006153,-0.145198,43.6,1.7274815646605128,8.790169362539299,2.1762315614461143e-09,0.20919656121586414,10857.67028807361,10.982494500172857,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M260B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,260.0,234.5,1.6268799999999999,1.64,0.992,60.0,8.79,38.21,8.45,30.81,0.006153,-0.145198,43.6,1.7274815646605128,8.790169362539299,2.1762315614461143e-09,0.20919656121586414,10857.67028807361,10.982494500172857,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P260A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,260.0,232.1,1.956,1.956,1.0,72.0,8.01,43.84,7.53,34.53,0.00171414,-0.14462816000000003,46.1,1.7818449845352218,8.015213286652832,1.6437786238585734e-10,0.5508769550585105,846.400021701308,5.156304786148223,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P260B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,260.0,236.5,1.6268799999999999,1.64,0.992,60.0,8.83,37.67,8.43,30.93,0.006181000000000001,-0.131845,43.2,1.653700935654957,8.830001701611339,1.1299883429899111e-09,0.19247821635314588,999999.7691261374,14.256210716433795,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P260B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,260.0,236.5,1.6268799999999999,1.64,0.992,60.0,8.83,37.67,8.43,30.93,0.006181000000000001,-0.131845,43.2,1.653700935654957,8.830001701611339,1.1299883429899111e-09,0.19247821635314588,999999.7691261374,14.256210716433795,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M265B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,265.0,239.1,1.6268799999999999,1.64,0.992,60.0,8.84,38.46,8.55,31.04,0.006188000000000001,-0.146148,43.6,1.742018842830358,8.86141474898932,2.2867590557044143e-09,0.18560941525242414,999999.4801868821,11.360470768440605,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M265B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,265.0,239.1,1.6268799999999999,1.64,0.992,60.0,8.84,38.46,8.55,31.04,0.006188000000000001,-0.146148,43.6,1.742018842830358,8.86141474898932,2.2867590557044143e-09,0.18560941525242414,999999.4801868821,11.360470768440605,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P265A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,265.0,236.7,1.956,1.956,1.0,72.0,8.1,43.99,7.65,34.65,0.0017334,-0.14512301000000002,46.1,1.7838921611129865,8.10029729005859,1.580630896599514e-10,0.545788173449827,14870.661611797219,4.714688050351483,-0.4702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P265B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,265.0,241.1,1.6268799999999999,1.64,0.992,60.0,9.02,38.17,8.58,30.97,0.006314000000000001,-0.133595,43.2,1.6630401457386426,9.020002291311858,9.711879907832362e-10,0.25370654419100247,999999.8673569047,12.66105911961036,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P265B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,265.0,241.1,1.6268799999999999,1.64,0.992,60.0,9.02,38.17,8.58,30.97,0.006314000000000001,-0.133595,43.2,1.6630401457386426,9.020002291311858,9.711879907832362e-10,0.25370654419100247,999999.8673569047,12.66105911961036,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M270B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,270.0,243.8,1.6268799999999999,1.64,0.992,60.0,9.26,38.79,8.69,31.07,0.006482000000000001,-0.147402,43.6,1.7338926124011693,9.263804956652944,1.7724084173268656e-09,0.3186762013777942,775.5535891726042,8.68426159343318,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M270B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,270.0,243.8,1.6268799999999999,1.64,0.992,60.0,9.26,38.79,8.69,31.07,0.006482000000000001,-0.147402,43.6,1.7338926124011693,9.263804956652944,1.7724084173268656e-09,0.3186762013777942,775.5535891726042,8.68426159343318,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P270A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,270.0,241.3,1.956,1.956,1.0,72.0,8.19,44.15,7.75,34.87,0.0017526599999999999,-0.14565085000000003,46.1,1.792522310137771,8.20124597956315,1.6487768840155818e-10,0.5266436958193872,999999.9828805715,4.964231730309948,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P270B3A,United Renewable Energy Co Ltd,Multi-c-Si,0,270.0,245.8,1.6268799999999999,1.64,0.992,60.0,9.15,38.39,8.73,31.04,0.006405000000000002,-0.13436499999999998,43.2,1.672263602968835,9.150002305828052,9.80305305501876e-10,0.25168542671316024,999999.5051212169,12.615561168355631,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P270B3AME,United Renewable Energy Co Ltd,Multi-c-Si,0,270.0,245.8,1.6268799999999999,1.64,0.992,60.0,9.15,38.39,8.73,31.04,0.006405000000000002,-0.13436499999999998,43.2,1.672263602968835,9.150002305828052,9.80305305501876e-10,0.25168542671316024,999999.5051212169,12.615561168355631,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6E270H3A,United Renewable Energy Co Ltd,Multi-c-Si,0,270.0,247.8,1.63,,,60.0,9.11,38.0,8.42,32.1,0.00526558,-0.111872,46.1,1.5152364451945712,9.121968003063985,1.1267908176685642e-10,0.1446479056198368,110.10545568448005,12.861510115954593,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E270H3F,United Renewable Energy Co Ltd,Multi-c-Si,0,270.0,244.9,1.61,,,60.0,9.2,38.0,8.55,31.6,0.0043884,-0.140182,46.0,1.5884237160201666,9.21150132101464,3.6533823778737563e-10,0.1896988383396835,151.741649623806,-1.124540054844892,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P270H3A,United Renewable Energy Co Ltd,Multi-c-Si,0,270.0,242.9,1.6268799999999999,,,60.0,8.97,38.2,8.24,32.8,0.003588,-0.11842000000000001,48.3,1.5886281363725383,8.975491607984509,3.092751464804664e-10,0.05872646175578512,95.92388515370158,16.61773195537682,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M275B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,275.0,248.4,1.6268799999999999,1.64,0.992,60.0,9.37,38.99,8.8,31.27,0.006559,-0.14816200000000002,43.6,1.7434483018952707,9.3732056802026,1.8090675411388944e-09,0.31120037960006547,909.6212038310077,8.759153547060059,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M275B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,275.0,248.4,1.6268799999999999,1.64,0.992,60.0,9.37,38.99,8.8,31.27,0.006559,-0.14816200000000002,43.6,1.7434483018952707,9.3732056802026,1.8090675411388944e-09,0.31120037960006547,909.6212038310077,8.759153547060059,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P275A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,245.9,1.956,1.956,1.0,72.0,8.31,44.31,7.87,34.96,0.00177834,-0.14617869000000003,46.1,1.7980453992230667,8.329158410083467,1.6523216002270628e-10,0.5259086088838274,999999.8369848628,4.8524096057984645,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P275B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,241.5,1.9503,1.97,0.99,72.0,8.2,44.72,7.71,35.68,0.01066,-0.183352,47.4,2.0926446859220564,8.20630873594813,4.2976833675728894e-09,0.4110267185128993,999999.9833692841,8.684353371191195,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P275B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,241.5,1.9503,1.97,0.99,72.0,8.2,44.72,7.71,35.68,0.01066,-0.183352,47.4,2.0926446859220564,8.20630873594813,4.2976833675728894e-09,0.4110267185128993,999999.9833692841,8.684353371191195,-0.51,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6Q275B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,244.1,1.9503,1.97,0.99,72.0,8.57,44.56,7.54,36.49,0.005999000000000001,-0.160416,47.4,2.0155792693251504,8.611209927650588,1.9646808284143664e-09,0.2795835537906892,58.14208931095437,16.716653646978862,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q275B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,244.1,1.9503,1.97,0.99,72.0,8.57,44.56,7.54,36.49,0.005999000000000001,-0.160416,47.4,2.0155792693251504,8.611209927650588,1.9646808284143664e-09,0.2795835537906892,58.14208931095437,16.716653646978862,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E275H3A,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,252.5,1.63,,,60.0,9.18,38.2,8.47,32.5,0.00530604,-0.11246080000000001,46.1,1.5306495201231647,9.189971313347964,1.2791050302886458e-10,0.11218730510973365,103.28423525047243,13.962283084577253,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E275H3F,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,249.6,1.61,,,60.0,9.25,38.15,8.65,31.8,0.0044122499999999995,-0.14073535,46.0,1.5913184091249883,9.258030074995691,3.516579097906381e-10,0.1804653184573774,207.88153687465112,-1.4916608909290423,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P275H3A,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,247.6,1.6268799999999999,,,60.0,9.05,38.3,8.28,33.2,0.0036200000000000004,-0.11873,48.3,1.6053249647023553,9.051322727102528,3.743619470188662e-10,0.012531588393605958,85.74019319254204,18.363707942989926,-0.42,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P275H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,275.0,248.3,1.9403519999999999,,,72.0,8.26,44.6,7.72,35.7,0.00413,-0.13826,47.2,1.7638412551316516,8.273397021946156,8.475718015050289e-11,0.4756340357006641,293.25452446923913,5.562489649284643,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L280L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,280.0,259.1,1.67,,,60.0,9.55,39.32,8.94,31.33,0.0069715,-0.12318956,42.535,1.5921127297413582,9.562243725949699,1.7729511781817248e-10,0.3717126718000466,289.93269342604503,9.260464244611336,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L280L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,280.0,260.1,1.67,,,60.0,9.55,39.32,8.94,31.33,0.006685000000000002,-0.09173356,41.08,1.577179952488005,9.562862983935752,1.4025510730733504e-10,0.37515601941097787,278.53104250428663,44.48287776912562,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M280B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,280.0,253.1,1.6268799999999999,1.64,0.992,60.0,9.53,39.04,8.95,31.33,0.006671000000000001,-0.148352,43.6,1.746389574772357,9.533318378368762,1.856440867632296e-09,0.3037054263366098,872.2090323670072,8.83873298637312,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M280B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,280.0,253.1,1.6268799999999999,1.64,0.992,60.0,9.53,39.04,8.95,31.33,0.006671000000000001,-0.148352,43.6,1.746389574772357,9.533318378368762,1.856440867632296e-09,0.3037054263366098,872.2090323670072,8.83873298637312,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M280E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,280.0,255.0,1.61,,,60.0,9.53,39.04,8.95,31.33,0.008577,-0.140544,43.41,1.7192907285288672,9.534129738515194,1.3039011419610545e-09,0.30974847697923924,714.7927719727425,11.453910652518534,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M280H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,280.0,256.2,1.61,,,60.0,9.53,39.04,8.95,31.33,0.0060038999999999995,-0.12375680000000001,45.18,1.5731908185655783,9.539042962392777,1.5746774399972911e-10,0.3430077677656373,361.4815900536741,7.075219094706736,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P280A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,250.5,1.956,1.956,1.0,72.0,8.42,44.39,7.99,35.05,0.0018018799999999998,-0.14644261000000003,46.1,1.8055021081931826,8.42000418448483,1.7691468590802829e-10,0.49677748093296337,999999.9393149917,5.335846743157559,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P280B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,246.0,1.9503,1.97,0.99,72.0,8.32,44.76,7.81,35.89,0.010816000000000001,-0.18351599999999998,47.4,2.102337911302198,8.321076531561035,4.709736026512477e-09,0.37809080271162665,2922.1281420895193,9.393425712224376,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P280B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,246.0,1.9503,1.97,0.99,72.0,8.32,44.76,7.81,35.89,0.010816000000000001,-0.18351599999999998,47.4,2.102337911302198,8.321076531561035,4.709736026512477e-09,0.37809080271162665,2922.1281420895193,9.393425712224376,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q280B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,248.7,1.9503,1.97,0.99,72.0,8.6,44.67,7.65,36.55,0.00602,-0.160812,47.4,2.005430683462852,8.63635146684316,1.6916769942633546e-09,0.28779159026917084,68.08550442996214,15.229976987312975,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q280B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,248.7,1.9503,1.97,0.99,72.0,8.6,44.67,7.65,36.55,0.00602,-0.160812,47.4,2.005430683462852,8.63635146684316,1.6916769942633546e-09,0.28779159026917084,68.08550442996214,15.229976987312975,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E280H3A,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,257.2,1.63,,,60.0,9.25,38.4,8.52,32.9,0.0053465,-0.1130496,46.1,1.546078416121185,9.257604389742264,1.4488463869491267e-10,0.0801155125562545,97.4527246689702,15.054001134512763,-0.3799,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E280H3F,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,254.3,1.61,,,60.0,9.35,38.3,8.75,32.0,0.00445995,-0.14128870000000002,46.0,1.5991017188629166,9.357395063850289,3.639219421063286e-10,0.16933890099551285,214.10482561960362,-1.3063572454786683,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K280H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,280.0,256.1,1.63,,,60.0,9.32,38.6,8.65,32.4,0.00367208,-0.1042586,47.3,1.4935484972503679,9.333807386082182,5.383286308810157e-11,0.1817555935666915,122.6852161506395,15.983333711540855,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P280H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,280.0,253.0,1.9403519999999999,,,72.0,8.34,44.8,7.78,36.0,0.00417,-0.13887999999999998,47.2,1.777299020515059,8.35490947735949,9.235623545676187e-11,0.45214268602148017,252.91765063106024,6.221497847447207,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L285L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,285.0,263.8,1.67,,,60.0,9.62,39.37,9.02,31.6,0.0070225999999999995,-0.12334621000000001,42.535,1.5994224102504435,9.630352477250042,1.9398031997667334e-10,0.3393659956213847,315.35459670238635,9.990856673809757,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L285L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,264.8,1.67,,,60.0,9.62,39.37,9.02,31.6,0.006734,-0.09185021,41.08,1.5838449888693333,9.630939114032863,1.521891713213495e-10,0.3429460369306089,301.59126904421487,45.35167763749576,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M285B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,254.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.12,9.07,31.5,0.0074074,-0.13692,47.4,1.7027022664240115,9.621323872278689,1.0101772342391474e-09,0.2982369711824389,2167.1647015764524,12.358837520728478,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M285B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,254.1,1.6268799999999999,1.64,0.992,60.0,9.62,39.12,9.07,31.5,0.0074074,-0.13692,47.4,1.7027022664240115,9.621323872278689,1.0101772342391474e-09,0.2982369711824389,2167.1647015764524,12.358837520728478,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M285B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,251.3,1.9503,1.97,0.99,72.0,8.75,43.93,8.03,35.48,0.007875,-0.17572000000000002,46.9,2.0372576597409546,8.769090062698947,3.6586945415941097e-09,0.3260925466338868,149.46579799062502,9.882258562432243,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M285B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,251.3,1.9503,1.97,0.99,72.0,8.75,43.93,8.03,35.48,0.007875,-0.17572000000000002,46.9,2.0372576597409546,8.769090062698947,3.6586945415941097e-09,0.3260925466338868,149.46579799062502,9.882258562432243,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M285E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,259.7,1.61,,,60.0,9.62,39.12,9.07,31.5,0.008657999999999999,-0.14083199999999998,43.41,1.7226390260362312,9.620777677950976,1.3188087045854446e-09,0.29381764489285167,3634.5838813267283,11.460518150023884,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M285H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,260.9,1.61,,,60.0,9.62,39.12,9.07,31.5,0.006060599999999999,-0.12401039999999999,45.18,1.5762580215503446,9.625178529072738,1.5924017429569178e-10,0.3267603039484011,607.0130519891703,7.077939396386182,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P285A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,255.1,1.956,1.956,1.0,72.0,8.51,44.53,8.12,35.1,0.0018211399999999997,-0.14690447,46.1,1.8142554845339647,8.510004022627099,1.8637389571769086e-10,0.4725083522606094,999985.680115981,5.6864121126257,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P285B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,250.6,1.9503,1.97,0.99,72.0,8.44,44.79,7.9,36.11,0.010972,-0.183639,47.4,2.1145072631188144,8.44341353699301,5.302244131927577e-09,0.34257300896798026,847.018572598591,10.356740814955945,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P285B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,250.6,1.9503,1.97,0.99,72.0,8.44,44.79,7.9,36.11,0.010972,-0.183639,47.4,2.1145072631188144,8.44341353699301,5.302244131927577e-09,0.34257300896798026,847.018572598591,10.356740814955945,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q285B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,253.3,1.9503,1.97,0.99,72.0,8.64,44.79,7.77,36.59,0.006048000000000001,-0.161244,47.4,1.9952771751576885,8.671470094023556,1.448349861192238e-09,0.2995277222252552,82.23425817253815,13.699422191149011,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q285B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,253.3,1.9503,1.97,0.99,72.0,8.64,44.79,7.77,36.59,0.006048000000000001,-0.161244,47.4,1.9952771751576885,8.671470094023556,1.448349861192238e-09,0.2995277222252552,82.23425817253815,13.699422191149011,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E285H3F,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,251.2,1.61,,,60.0,9.45,38.6,8.85,32.25,0.0059535000000000005,-0.138574,48.8,1.733808946595423,9.454572209391186,1.998561116115996e-09,0.139952156659447,289.25808701623646,16.14607839570496,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K285H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,285.0,260.8,1.63,,,60.0,9.39,38.8,8.7,32.8,0.00369966,-0.1047988,47.3,1.5083259222522845,9.402356810821827,6.102370984658322e-11,0.15015534547350756,114.10377038874203,17.10091577104765,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P285H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,285.0,257.6,1.9403519999999999,,,72.0,8.43,45.0,7.83,36.4,0.004215,-0.1395,47.2,1.7958199738065121,8.447854269396178,1.0767060301114929e-10,0.41345553704590327,195.215509821717,7.4687639109170725,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L290L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,290.0,268.6,1.67,,,60.0,9.69,39.42,9.1,31.87,0.0070737,-0.12350286000000002,42.535,1.6066887101244656,9.698626815955814,2.1192663753964242e-10,0.3076351185419322,345.5486600589071,10.713532061691916,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L290L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,269.6,1.67,,,60.0,9.69,39.42,9.1,31.87,0.006783000000000001,-0.09196686000000001,41.08,1.5904679889896716,9.69917782687391,1.6492053046421833e-10,0.3113503142834304,328.7254042725761,46.210593168039615,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M290B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,258.7,1.6268799999999999,1.64,0.992,60.0,9.68,39.18,9.18,31.61,0.0074535999999999995,-0.13712999999999997,47.4,1.7053580197048417,9.720466068378313,1.0231105034870346e-09,0.28781804050818915,999999.933555322,12.3787451854743,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M290B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,258.7,1.6268799999999999,1.64,0.992,60.0,9.68,39.18,9.18,31.61,0.0074535999999999995,-0.13712999999999997,47.4,1.7053580197048417,9.720466068378313,1.0231105034870346e-09,0.28781804050818915,999999.933555322,12.3787451854743,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M290B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,255.9,1.9503,1.97,0.99,72.0,8.76,44.44,8.07,35.96,0.007883999999999999,-0.17776,46.9,2.05871475320049,8.776005634971929,3.595475652373146e-09,0.3201271951054806,175.2080478926688,9.703957341658546,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M290B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,255.9,1.9503,1.97,0.99,72.0,8.76,44.44,8.07,35.96,0.007883999999999999,-0.17776,46.9,2.05871475320049,8.776005634971929,3.595475652373146e-09,0.3201271951054806,175.2080478926688,9.703957341658546,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M290E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,264.4,1.61,,,60.0,9.68,39.18,9.18,31.61,0.008712,-0.14104799999999998,43.41,1.7257517716356015,9.726138624161514,1.3430317343362633e-09,0.2832519055262382,999999.980062361,11.528354896962782,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M290H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,265.6,1.61,,,60.0,9.68,39.18,9.18,31.61,0.0060983999999999995,-0.1242006,45.18,1.5760679019927957,9.684192936132026,1.548066634586505e-10,0.31722862757152825,999999.9276449179,6.758110948381161,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P290A4F,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,259.7,1.956,1.956,1.0,72.0,8.62,44.61,8.24,35.2,0.0018446799999999998,-0.14716839,46.1,1.8198738015421632,8.620004184957411,1.9488554123365336e-10,0.452522511764269,931597.889956603,5.956258091258591,-0.4702,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P290B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,255.1,1.9503,1.97,0.99,72.0,8.56,44.82,8.0,36.32,0.011128,-0.18376199999999998,47.4,2.124732414371491,8.564498632946673,5.85648424438145e-09,0.3096690186772888,589.2401971812096,11.151054254145473,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P290B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,255.1,1.9503,1.97,0.99,72.0,8.56,44.82,8.0,36.32,0.011128,-0.18376199999999998,47.4,2.124732414371491,8.564498632946673,5.85648424438145e-09,0.3096690186772888,589.2401971812096,11.151054254145473,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q290B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,257.8,1.9503,1.97,0.99,72.0,8.67,44.9,7.9,36.64,0.006069000000000001,-0.16164,47.4,1.983149475069852,8.694253019443664,1.218038005729881e-09,0.3086727841237564,110.34475226236943,12.03065274310009,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q290B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,257.8,1.9503,1.97,0.99,72.0,8.67,44.9,7.9,36.64,0.006069000000000001,-0.16164,47.4,1.983149475069852,8.694253019443664,1.218038005729881e-09,0.3086727841237564,110.34475226236943,12.03065274310009,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E290H3F,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,255.8,1.61,,,60.0,9.55,38.9,8.95,32.45,0.006016500000000001,-0.139651,48.8,1.7449448765957745,9.554498446561613,1.9623240141659725e-09,0.14646183582811792,310.93206213459183,15.869665293422878,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K290H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,290.0,265.5,1.63,,,60.0,9.46,39.0,8.75,33.2,0.0037272400000000006,-0.105339,47.3,1.5231275567818252,9.470525781697125,6.904132060312946e-11,0.11892269891724865,106.8812533068898,18.210927721110334,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P290H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,290.0,262.2,1.9403519999999999,,,72.0,8.52,45.2,7.88,36.8,0.00426,-0.14012,47.2,1.814451917092254,8.540014304779307,1.253341052221759e-10,0.3752200317596705,159.72949360591485,8.718036106710827,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L295L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,295.0,273.3,1.67,,,60.0,9.76,39.47,9.18,32.14,0.0071248,-0.12365951000000001,42.535,1.6139127367801906,9.76706513560384,2.312057553638712e-10,0.2765023117716285,381.96902306979797,11.428663585893327,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L295L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,274.3,1.67,,,60.0,9.76,39.47,9.18,32.14,0.006832000000000001,-0.09208351000000001,41.08,1.597050071636819,9.767577713873784,1.784876988548283e-10,0.2803511263735199,361.08875744827475,47.059851464207426,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M295B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,263.4,1.6268799999999999,1.64,0.992,60.0,9.73,39.27,9.26,31.86,0.007492100000000001,-0.137445,47.4,1.7207493617827456,9.730002310422599,1.1936589440336888e-09,0.2371072162258181,999999.9411021002,13.78658702240482,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M295B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,263.4,1.6268799999999999,1.64,0.992,60.0,9.73,39.27,9.26,31.86,0.007492100000000001,-0.137445,47.4,1.7207493617827456,9.730002310422599,1.1936589440336888e-09,0.2371072162258181,999999.9411021002,13.78658702240482,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M295B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,260.4,1.9503,1.97,0.99,72.0,8.78,44.94,8.11,36.44,0.007902,-0.17976,46.9,2.081338741214488,8.793827566785819,3.5942686799843094e-09,0.3123691253815305,198.3431295417338,9.673515324902212,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M295B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,260.4,1.9503,1.97,0.99,72.0,8.78,44.94,8.11,36.44,0.007902,-0.17976,46.9,2.081338741214488,8.793827566785819,3.5942686799843094e-09,0.3123691253815305,198.3431295417338,9.673515324902212,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M295E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,269.1,1.61,,,60.0,9.73,39.27,9.26,31.86,0.008757000000000001,-0.14137200000000003,43.41,1.74210994803495,9.730002243170116,1.5790836398714704e-09,0.23011704502967384,999999.9406159016,13.006957541503056,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M295H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,270.3,1.61,,,60.0,9.73,39.27,9.26,31.86,0.006129900000000001,-0.12448590000000001,45.18,1.5866954591757179,9.73000273469593,1.735872536620197e-10,0.28097585118713825,999999.8913470671,7.708406553695762,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P295B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,295.0,259.7,1.9503,1.97,0.99,72.0,8.68,44.85,8.1,36.54,0.011284,-0.183885,47.4,2.1352939954353674,8.685304864011178,6.48355598862553e-09,0.27611256772112996,451.78597465185413,11.97542595832273,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P295B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,295.0,259.7,1.9503,1.97,0.99,72.0,8.68,44.85,8.1,36.54,0.011284,-0.183885,47.4,2.1352939954353674,8.685304864011178,6.48355598862553e-09,0.27611256772112996,451.78597465185413,11.97542595832273,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q295B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,295.0,262.4,1.9503,1.97,0.99,72.0,8.71,45.02,8.02,36.69,0.006097000000000002,-0.16207200000000002,47.4,1.9747769073193,8.728130700170244,1.059615895947142e-09,0.31753141657497275,152.5423217119908,10.690125204234445,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6Q295B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,295.0,262.4,1.9503,1.97,0.99,72.0,8.71,45.02,8.02,36.69,0.006097000000000002,-0.16207200000000002,47.4,1.9747769073193,8.728130700170244,1.059615895947142e-09,0.31753141657497275,152.5423217119908,10.690125204234445,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K295H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,270.2,1.63,,,60.0,9.64,39.7,9.12,32.4,0.00379816,-0.10722970000000001,47.3,1.4993161827951962,9.645558413261679,3.0291302490422016e-11,0.3008258574535284,521.7246763872829,10.332561165060683,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K295H3F,United Renewable Energy Co Ltd,Mono-c-Si,0,295.0,270.9,1.61,,,60.0,9.55,39.6,9.05,32.6,0.0048991500000000006,-0.12347280000000001,45.4,1.5711018558350105,9.55241960615854,1.0759453742064643e-10,0.2502872567884695,987.8647701121014,5.685747897931503,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P295H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,295.0,266.9,1.9403519999999999,,,72.0,8.61,45.4,7.93,37.2,0.004305,-0.14074,47.2,1.833192612131613,8.631408735490343,1.4567244164607798e-10,0.3374271135540733,135.70383573771772,9.969020947995524,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L300L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,300.0,278.1,1.67,,,60.0,9.85,39.61,9.27,32.39,0.0071905,-0.12409813000000001,42.535,1.6229679915696478,9.856510794919908,2.454005608502941e-10,0.2577773306967841,389.984187363324,11.883697870984276,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L300L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,279.1,1.67,,,60.0,9.85,39.61,9.27,32.39,0.006895000000000001,-0.09241013000000001,41.08,1.6056485670268683,9.857006360693264,1.8849327668993443e-10,0.26170428102844207,367.9210302657989,47.600498384674225,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M300B3A,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,268.0,1.6268799999999999,1.64,0.992,60.0,9.78,39.39,9.35,32.09,0.0075306,-0.137865,47.4,1.7333399186512912,9.78000197384988,1.3213947827490627e-09,0.20153873458882382,999998.7270643716,14.685889462031525,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M300B3AME,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,268.0,1.6268799999999999,1.64,0.992,60.0,9.78,39.39,9.35,32.09,0.0075306,-0.137865,47.4,1.7333399186512912,9.78000197384988,1.3213947827490627e-09,0.20153873458882382,999998.7270643716,14.685889462031525,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M300B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,265.0,1.9503,1.97,0.99,72.0,8.79,45.44,8.14,36.92,0.007911,-0.18176,46.9,2.104020877966601,8.801824611750492,3.5910723896025527e-09,0.30504094877849924,226.75687605958797,9.648576692790364,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M300B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,265.0,1.9503,1.97,0.99,72.0,8.79,45.44,8.14,36.92,0.007911,-0.18176,46.9,2.104020877966601,8.801824611750492,3.5910723896025527e-09,0.30504094877849924,226.75687605958797,9.648576692790364,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M300E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,273.8,1.61,,,60.0,9.78,39.39,9.35,32.09,0.008801999999999999,-0.141804,43.41,1.7549641163638572,9.780001903796265,1.7483948241970067e-09,0.1943128297398911,999999.9632905457,13.905616843782534,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M300H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,275.0,1.61,,,60.0,9.78,39.39,9.35,32.09,0.0061614,-0.12486630000000001,45.18,1.5979704327319517,9.780002414128495,1.9273935339554508e-10,0.2467735712843152,999998.7991790981,8.577644351633937,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P300B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,300.0,273.2,1.9403519999999999,1.956,0.992,72.0,8.52,46.47,8.12,36.97,0.006816,-0.16264499999999998,43.2,2.004126432917766,8.520003539299427,7.250731511581261e-10,0.4149987705397717,999999.2951230366,10.414552835012104,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P300B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,300.0,273.2,1.9403519999999999,1.956,0.992,72.0,8.52,46.47,8.12,36.97,0.006816,-0.16264499999999998,43.2,2.004126432917766,8.520003539299427,7.250731511581261e-10,0.4149987705397717,999999.2951230366,10.414552835012104,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K300H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,274.9,1.63,,,60.0,9.71,39.9,9.16,32.8,0.00382574,-0.1077699,47.3,1.5145951776152005,9.717794323714537,3.477972265190286e-11,0.2702092775515807,336.62086150074254,11.520303186009684,-0.378,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K300H3F,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,275.6,1.61,,,60.0,9.7,39.7,9.2,32.7,0.004976099999999999,-0.12378460000000001,45.4,1.57484994146365,9.701849390573583,1.0900520122109731e-10,0.24487793749701034,1284.3779567910437,5.660812534088088,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M300H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M300H3A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M300H3A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M300H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M300H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M300H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P300H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,300.0,271.5,1.9403519999999999,,,72.0,8.68,45.6,7.98,37.6,0.00434,-0.14136,47.2,1.849697167829168,8.700644031091425,1.6393502157887177e-10,0.301206103285567,126.64527724801933,10.958146178260154,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L305L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,305.0,282.8,1.67,,,60.0,9.91,39.71,9.39,32.5,0.0072343,-0.12441143000000002,42.535,1.6199835146097779,9.910005953536364,2.240706666868345e-10,0.2543437204576166,423429.1858183339,10.978423316071623,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L305L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.8,1.67,,,60.0,9.91,39.71,9.39,32.5,0.006937000000000001,-0.09264343,41.08,1.6053235255629545,9.911567100772457,1.78719045600427e-10,0.2576710856495617,1629.4558980303605,46.85593268913664,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M305B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,269.6,1.9503,1.97,0.99,72.0,8.8,45.95,8.18,37.3,0.00792,-0.18380000000000002,46.9,2.1217017436572863,8.809502367597304,3.4002714266743074e-09,0.31404027947350344,290.8282677832368,9.134182229046655,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M305B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,269.6,1.9503,1.97,0.99,72.0,8.8,45.95,8.18,37.3,0.00792,-0.18380000000000002,46.9,2.1217017436572863,8.809502367597304,3.4002714266743074e-09,0.31404027947350344,290.8282677832368,9.134182229046655,-0.51,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M305E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,278.5,1.61,,,60.0,9.86,39.49,9.43,32.35,0.008873999999999998,-0.142164,43.41,1.7645301177522603,9.860001689104152,1.8810920183699286e-09,0.17100328265323184,999998.9284636676,14.513991660685303,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M305H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,279.8,1.61,,,60.0,9.86,39.49,9.43,32.35,0.0062118,-0.1251833,45.18,1.606417183746633,9.860002204584427,2.0785654169648316e-10,0.22352641021366312,999998.996454263,9.169961686677489,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P305B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,305.0,277.9,1.9403519999999999,1.956,0.992,72.0,8.56,46.87,8.2,37.27,0.006848000000000001,-0.164045,43.2,2.025996086756614,8.560003322721828,7.68020822693479e-10,0.387795529943128,999997.9314972494,10.89057194670081,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P305B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,305.0,277.9,1.9403519999999999,1.956,0.992,72.0,8.56,46.87,8.2,37.27,0.006848000000000001,-0.164045,43.2,2.025996086756614,8.560003322721828,7.68020822693479e-10,0.387795529943128,999997.9314972494,10.89057194670081,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K305H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,285.3,1.66,,,60.0,9.72,40.04,9.24,33.01,0.0104004,-0.128128,42.71,1.6122983002905389,9.72000296725958,1.5934754090381236e-10,0.23715654837925562,776998.107518392,5.429835035224012,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K305H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,285.6,1.645,,,20.0,9.89,39.98,9.44,32.35,0.0029274400000000003,-0.09151422,45.6,1.363946733518943,9.890606939401808,1.840288591776708e-12,0.36011539641314,5868.034809863534,3.583941931962695,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K305H3F,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,280.3,1.61,,,60.0,9.8,39.8,9.3,32.8,0.0050274000000000004,-0.1240964,45.4,1.5788344998382555,9.801482396608446,1.1022595631111326e-10,0.24083255970365877,1592.124319929604,5.666328528462093,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M305H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M305H3A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M305H3A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M305H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M305H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M305H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P305H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,305.0,276.2,1.9403519999999999,,,72.0,8.75,45.8,8.03,38.0,0.004375,-0.14198,47.2,1.8662290036455311,8.769528190679633,1.8418327082228718e-10,0.2654408997057717,118.93615562311544,11.941898759580388,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L310L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,310.0,287.6,1.67,,,60.0,9.99,39.81,9.48,32.76,0.0072927,-0.12472473,42.535,1.6299256077434896,9.990342225565854,2.4656368395645986e-10,0.23063576813061423,6732.566811785484,11.769961952446115,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L310L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,288.6,1.67,,,60.0,9.99,39.81,9.48,32.76,0.006993000000000001,-0.09287673,41.08,1.612585118950977,9.990708515438214,1.895024178536707e-10,0.234491845040672,3306.3155099212872,47.45292200388655,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M310B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,278.9,1.9403519999999999,1.956,0.992,72.0,8.86,45.92,8.44,36.78,0.006202,-0.16990400000000003,43.6,2.074517203075091,8.860002961398601,2.1587664845757746e-09,0.3334748784448921,999999.7106441441,13.857990117141766,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M310B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,278.9,1.9403519999999999,1.956,0.992,72.0,8.86,45.92,8.44,36.78,0.006202,-0.16990400000000003,43.6,2.074517203075091,8.860002961398601,2.1587664845757746e-09,0.3334748784448921,999999.7106441441,13.857990117141766,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M310E3A,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,283.2,1.61,,,60.0,9.91,39.75,9.52,32.57,0.008919,-0.1431,43.41,1.7808940782202978,9.910136212335022,2.006116922765743e-09,0.14761538879774597,10739.819710365817,15.07304591929103,-0.48,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M310H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,284.5,1.61,,,60.0,9.91,39.75,9.52,32.57,0.0062433,-0.1260075,45.18,1.6210007624053318,9.91018247618726,2.2192285998570494e-10,0.20210363173460702,10975.968592154497,9.705186363227366,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P310B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,310.0,282.5,1.9403519999999999,1.956,0.992,72.0,8.6,47.27,8.27,37.56,0.00688,-0.165445,43.2,2.047095864897935,8.600226124243088,8.052597509165313e-10,0.36512225045852487,13886.033150917967,11.277623680819504,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P310B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,310.0,282.5,1.9403519999999999,1.956,0.992,72.0,8.6,47.27,8.27,37.56,0.00688,-0.165445,43.2,2.047095864897935,8.600226124243088,8.052597509165313e-10,0.36512225045852487,13886.033150917967,11.277623680819504,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K310H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,290.1,1.66,,,60.0,9.86,40.09,9.37,33.09,0.0105502,-0.128288,42.71,1.6151522313609057,9.860063524410009,1.63728529170577e-10,0.22931644183975744,35593.834707236034,5.540211688962204,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E310H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,310.0,282.6,1.94,,,72.0,8.98,45.2,8.29,37.4,0.00795628,-0.1440072,47.2,1.8524792455243106,8.997129886736065,2.1953079083416237e-10,0.26593986078399423,139.41364978768348,9.721504660095176,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K310H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,290.4,1.645,,,20.0,10.1,40.1,9.56,32.46,0.0029896,-0.0917889,45.6,1.3731245849810796,10.11023192436811,2.074359350437409e-12,0.3529790731931446,348.42797111830754,4.473849272137316,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K310H3F,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,285.0,1.61,,,60.0,9.9,39.9,9.43,32.9,0.0050787,-0.12440820000000001,45.4,1.5827400530193925,9.90000306941006,1.1150894809230532e-10,0.23665549392700028,763396.9632724393,5.670435472942462,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K310H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,286.7,1.6626506,,,60.0,9.92,40.2,9.4,33.0,0.00393824,-0.10689180000000002,45.5,1.5083187821285657,9.924687607617333,2.6229466163808863e-11,0.275481085827521,582.9780717185328,10.527167469039822,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K310H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,286.7,1.6626506,,,60.0,9.92,40.2,9.4,33.0,0.00393824,-0.10689180000000002,45.5,1.5083187821285657,9.924687607617333,2.6229466163808863e-11,0.275481085827521,582.9780717185328,10.527167469039822,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M310H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M310H3A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M310H3A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M310H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M310H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M310H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P310H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,310.0,280.8,1.9403519999999999,,,72.0,8.82,46.0,8.08,38.4,0.00441,-0.1426,47.2,1.8827871342254126,8.838074383529849,2.0659672042571828e-10,0.23012240177670093,112.29592412848577,12.920231174630409,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L315L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,315.0,292.3,1.67,,,60.0,10.07,39.91,9.57,32.97,0.0073511,-0.12503803,42.535,1.6372819481371474,10.070002950311341,2.6107603539822585e-10,0.21373501899670008,729696.0101368945,12.21431681579592,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L315L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,293.4,1.67,,,60.0,10.07,39.91,9.57,32.97,0.0070490000000000014,-0.09311003,41.08,1.618731582544899,10.07159971137515,1.974785431799496e-10,0.21778775400199626,999999.9311398037,47.84340716651326,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M315B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,283.6,1.9403519999999999,1.956,0.992,72.0,8.92,46.19,8.52,37.02,0.006244,-0.170903,43.6,2.09016729987481,8.920002812951317,2.254317812004843e-09,0.3146375420757116,999997.9661138692,14.199299260381363,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M315B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,283.6,1.9403519999999999,1.956,0.992,72.0,8.92,46.19,8.52,37.02,0.006244,-0.170903,43.6,2.09016729987481,8.920002812951317,2.254317812004843e-09,0.3146375420757116,999997.9661138692,14.199299260381363,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M315E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,281.4,1.9403519999999999,1.956,0.992,72.0,9.07,45.27,8.53,36.96,0.004535,-0.158445,47.51,1.909989268462601,9.075288511924652,4.574063693090752e-10,0.31419581517636314,538.8579875796183,6.1923619610460925,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M315E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,281.4,1.9403519999999999,1.956,0.992,72.0,9.07,45.27,8.53,36.96,0.004535,-0.158445,47.51,1.909989268462601,9.075288511924652,4.574063693090752e-10,0.31419581517636314,538.8579875796183,6.1923619610460925,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M315H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,289.2,1.61,,,60.0,9.96,39.99,9.61,32.78,0.0062748000000000005,-0.1267683,45.18,1.6344940503411736,9.96016175621293,2.357953245797884e-10,0.17936903649910174,11044.526249200744,10.19902218537019,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P315B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,315.0,287.2,1.9403519999999999,1.956,0.992,72.0,9.01,45.91,8.49,37.18,0.007208,-0.16068499999999997,43.2,1.9920445833287506,9.012319142649293,8.793265049505989e-10,0.3471405645404145,1348.6626190616753,11.662587801587998,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P315B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,315.0,287.2,1.9403519999999999,1.956,0.992,72.0,9.01,45.91,8.49,37.18,0.007208,-0.16068499999999997,43.2,1.9920445833287506,9.012319142649293,8.793265049505989e-10,0.3471405645404145,1348.6626190616753,11.662587801587998,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K315H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,294.9,1.66,,,60.0,10.0,40.15,9.49,33.18,0.010700000000000001,-0.12847999999999998,42.71,1.61761352382761,10.000005348254964,1.661818240158168e-10,0.22176207812318682,413864.9072215394,5.546597789923729,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E315H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,315.0,287.3,1.94,,,72.0,9.05,45.4,8.34,37.8,0.0080183,-0.1446444,47.2,1.869109091579482,9.06614617038108,2.463125003380816e-10,0.2317111675800731,129.87513958721044,10.690538681647292,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K315H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,295.2,1.645,,,20.0,10.21,40.22,9.67,32.58,0.0030221600000000003,-0.09206357999999999,45.6,1.3773252688604458,10.21963011238594,2.10236844936149e-12,0.347464066273353,368.38698595636754,4.493497500530651,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K315H3F,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,289.8,1.61,,,60.0,10.0,40.0,9.55,33.0,0.00513,-0.12472000000000001,45.4,1.5890278746532005,10.000002170149946,1.168602983335966e-10,0.21698083150913758,999999.8260907069,5.984453454861893,-0.4035,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K315H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,291.5,1.6626506,,,60.0,10.01,40.4,9.49,33.2,0.003973969999999999,-0.10742360000000001,45.5,1.5162980210567456,10.014312294120787,2.670205506788251e-11,0.27002094831551277,626.7916071715464,10.604202267207045,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K315H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,291.5,1.6626506,,,60.0,10.01,40.4,9.49,33.2,0.003973969999999999,-0.10742360000000001,45.5,1.5162980210567456,10.014312294120787,2.670205506788251e-11,0.27002094831551277,626.7916071715464,10.604202267207045,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M315H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M315H3A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M315H3A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M315H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M315H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M315H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P315H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,315.0,285.5,1.9403519999999999,,,72.0,8.89,46.2,8.13,38.8,0.004445,-0.14322000000000001,47.2,1.8993706055630708,8.906295079200367,2.313673949461282e-10,0.19524178895723676,106.51679070121835,13.893100589976234,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M315H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,291.1,1.681248,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M315H7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,291.1,1.681248,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M315H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,315.0,291.1,1.681248,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K320P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,320.0,294.6,1.71,,,60.0,10.3,40.22,9.76,33.2,0.006180000000000001,-0.12335473999999999,45.58,1.5871545609545625,10.302974374124558,1.0124435028834835e-10,0.22740270188442832,787.4759530361376,6.174912509781714,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L320L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,320.0,297.1,1.67,,,60.0,10.14,40.01,9.67,33.19,0.007402199999999999,-0.12535133,42.535,1.6472415381897783,10.140001846525468,2.8669362011383806e-10,0.18204450453508797,999999.9611214614,13.004451044021355,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L320L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,298.2,1.67,,,60.0,10.14,40.01,9.67,33.19,0.007098000000000001,-0.09334333,41.08,1.6279902340672427,10.140001908425525,2.1511889036093617e-10,0.18815948565841425,999999.7520370437,48.7899338278755,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M320B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,288.2,1.9403519999999999,1.956,0.992,72.0,8.99,46.46,8.61,37.27,0.006293000000000001,-0.171902,43.6,2.106934715297132,8.99022940756178,2.3820452835387946e-09,0.29118055743066956,11411.045537628946,14.643776954166213,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M320B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,288.2,1.9403519999999999,1.956,0.992,72.0,8.99,46.46,8.61,37.27,0.006293000000000001,-0.171902,43.6,2.106934715297132,8.99022940756178,2.3820452835387946e-09,0.29118055743066956,11411.045537628946,14.643776954166213,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M320E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,286.0,1.9403519999999999,1.956,0.992,72.0,9.16,45.46,8.64,37.09,0.00458,-0.15911,47.51,1.9142266642984338,9.163195776251474,4.4240856229903025e-10,0.31622546589354167,906.3922059653797,5.811565028857529,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M320E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,286.0,1.9403519999999999,1.956,0.992,72.0,9.16,45.46,8.64,37.09,0.00458,-0.15911,47.51,1.9142266642984338,9.163195776251474,4.4240856229903025e-10,0.31622546589354167,906.3922059653797,5.811565028857529,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M320H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,293.9,1.61,,,60.0,10.28,40.07,9.76,32.8,0.0064764,-0.1270219,45.18,1.6238872810365708,10.280003534190843,1.975236542245487e-10,0.2489688834246642,724338.0384502879,8.355668198481224,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P320B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,320.0,291.9,1.9403519999999999,1.956,0.992,72.0,9.1,46.15,8.58,37.36,0.00728,-0.161525,43.2,2.001355928161918,9.10184352463107,8.775831388383297e-10,0.3475571970006626,1715.6138007005918,11.552012963143142,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P320B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,320.0,291.9,1.9403519999999999,1.956,0.992,72.0,9.1,46.15,8.58,37.36,0.00728,-0.161525,43.2,2.001355928161918,9.10184352463107,8.775831388383297e-10,0.3475571970006626,1715.6138007005918,11.552012963143142,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K320H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,299.7,1.66,,,60.0,10.14,40.2,9.62,33.26,0.0108498,-0.12864,42.71,1.6231302961526566,10.141346914245263,1.7736648567082369e-10,0.21380735464723843,1609.610434979698,5.993959148475418,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E320H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,320.0,292.0,1.94,,,72.0,9.12,45.6,8.39,38.2,0.008080319999999998,-0.1452816,47.2,1.8857451036711148,9.134820409851635,2.7584445311527977e-10,0.1978994806558308,121.78093153521027,11.651879205863366,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E320H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,320.0,288.7,1.92,,,72.0,9.15,46.5,8.5,37.65,0.006222000000000001,-0.17205,46.1,1.9896189094852617,9.164853591623409,6.337650852642336e-10,0.3559847837526702,219.29116060374292,2.8520681193834876,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K320H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,300.0,1.645,,,20.0,10.32,40.34,9.78,32.72,0.0030547200000000004,-0.09233826,45.6,1.3819220627412854,10.329032121688812,2.1482232912941347e-12,0.3397363942667371,388.17895928605316,4.5850018530415495,-0.3116,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K320H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,296.2,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00401764,-0.10795540000000002,45.5,1.5249576510772322,10.124734683161039,2.752744209195485e-11,0.2641028903557208,564.4984535624722,10.78115587885921,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K320H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,296.2,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00401764,-0.10795540000000002,45.5,1.5249576510772322,10.124734683161039,2.752744209195485e-11,0.2641028903557208,564.4984535624722,10.78115587885921,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M320H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,297.3,1.607856,,,60.0,10.12,40.6,9.59,33.4,0.00380512,-0.1101478,45.3,1.5070035784881617,10.125231454016527,2.003366575339234e-11,0.2681842317724691,518.7897035974919,5.840439655238546,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M320H3A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,297.3,1.607856,,,60.0,10.12,40.6,9.59,33.4,0.00380512,-0.1101478,45.3,1.5070035784881617,10.125231454016527,2.003366575339234e-11,0.2681842317724691,518.7897035974919,5.840439655238546,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M320H3A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,297.3,1.607856,,,60.0,10.12,40.6,9.59,33.4,0.00380512,-0.1101478,45.3,1.5070035784881617,10.125231454016527,2.003366575339234e-11,0.2681842317724691,518.7897035974919,5.840439655238546,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M320H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,294.5,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M320H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,294.5,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M320H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,294.5,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P320H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,320.0,290.1,1.9403519999999999,,,72.0,8.96,46.4,8.19,39.1,0.0044800000000000005,-0.14384,47.2,1.9118296198173335,8.975036390412123,2.458769246224563e-10,0.1755255116186818,104.5934944374863,14.384355592670948,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K320H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,297.1,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.0035798400000000004,-0.1073742,46.0,1.470586869614562,10.17808480595428,1.3493971541644573e-11,0.24329426452417346,306.043546658805,4.137005085250907,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K320H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,297.1,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.0035798400000000004,-0.1073742,46.0,1.470586869614562,10.17808480595428,1.3493971541644573e-11,0.24329426452417346,306.043546658805,4.137005085250907,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M320H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,295.8,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M320H7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,295.8,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M320H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,320.0,295.8,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K325P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,325.0,299.4,1.71,,,60.0,10.44,40.28,9.76,33.3,0.006264,-0.12353876,45.58,1.6019393647799973,10.45283809373517,1.2289419888707597e-10,0.21729692940558815,176.7069206353786,7.783939063862936,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L325L3A,United Renewable Energy Co Ltd,Mono-c-Si,1,325.0,301.9,1.67,,,60.0,10.22,40.11,9.76,33.4,0.0074606,-0.12566463,42.535,1.6553660638856642,10.22000165164413,3.0645588307811364e-10,0.16155762689097256,999999.9163007289,13.54373748589501,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L325L3A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,303.0,1.67,,,60.0,10.22,40.11,9.76,33.4,0.0071540000000000015,-0.09357663000000001,41.08,1.6355643588635784,10.220001715842843,2.2854171812503385e-10,0.16784901818960224,999999.752667031,49.42615139777134,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M325B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,292.9,1.9403519999999999,1.956,0.992,72.0,9.24,45.65,8.74,37.22,0.0064680000000000015,-0.168905,43.6,2.070722031600776,9.260848413922423,2.4684886884234225e-09,0.2826228964048659,999999.9846085879,14.700216818065364,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M325B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,292.9,1.9403519999999999,1.956,0.992,72.0,9.24,45.65,8.74,37.22,0.0064680000000000015,-0.168905,43.6,2.070722031600776,9.260848413922423,2.4684886884234225e-09,0.2826228964048659,999999.9846085879,14.700216818065364,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M325E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,290.6,1.9403519999999999,1.956,0.992,72.0,9.24,45.65,8.74,37.22,0.004620000000000001,-0.159775,47.51,1.9186030885258678,9.241093216388963,4.28157849414147e-10,0.31850824012204393,2692.0748337672394,5.447711766050163,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M325E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,290.6,1.9403519999999999,1.956,0.992,72.0,9.24,45.65,8.74,37.22,0.004620000000000001,-0.159775,47.51,1.9186030885258678,9.241093216388963,4.28157849414147e-10,0.31850824012204393,2692.0748337672394,5.447711766050163,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M325H3A,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,298.7,1.61,,,60.0,10.38,40.13,9.9,32.83,0.0065394,-0.12721210000000002,45.18,1.6293346385760654,10.380002403421317,2.0876572467879533e-10,0.23147116166288684,999990.5165201144,8.756082719837394,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P325B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,325.0,296.6,1.9403519999999999,1.956,0.992,72.0,9.19,46.38,8.68,37.52,0.007352,-0.16233,43.2,2.0086314261931606,9.190402220720685,8.610910185327586e-10,0.34963225238846857,7988.517412192366,11.284417790566339,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P325B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,325.0,296.6,1.9403519999999999,1.956,0.992,72.0,9.19,46.38,8.68,37.52,0.007352,-0.16233,43.2,2.0086314261931606,9.190402220720685,8.610910185327586e-10,0.34963225238846857,7988.517412192366,11.284417790566339,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K325H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,304.5,1.66,,,60.0,10.28,40.25,9.75,33.34,0.0109996,-0.1288,42.71,1.6231113157627015,10.280004625068097,1.7471578888981216e-10,0.20715990612300397,460495.3113856655,5.73978099462477,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K325H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K325H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M325H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M325H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M325H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E325H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,325.0,296.7,1.94,,,72.0,9.19,45.8,8.44,38.6,0.00814234,-0.1459188,47.2,1.9023865322477562,9.203165345383704,3.0835085562978374e-10,0.16449684882875643,114.82616214374859,12.605539173024196,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E325H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,325.0,293.4,1.92,,,72.0,9.2,46.6,8.6,37.8,0.006256,-0.17242000000000002,46.1,1.9891846705774008,9.209724677506173,6.072980058407063e-10,0.3460179610789827,327.3492643940276,2.432817621501005,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K325H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K325H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M325H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M325H3G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M325H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6P325H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,325.0,294.8,1.9403519999999999,,,72.0,9.02,46.6,8.23,39.5,0.00451,-0.14446,47.2,1.9285592869046206,9.032815967277655,2.746791100142395e-10,0.14156703556771966,99.63623178141529,15.358960897877559,-0.41,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K325H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,301.9,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0036185600000000003,-0.10790839999999999,46.0,1.4789509114164092,10.288402165735683,1.3898622943443762e-11,0.23780505783233014,290.9530814429537,4.297942002643689,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K325H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,301.9,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0036185600000000003,-0.10790839999999999,46.0,1.4789509114164092,10.288402165735683,1.3898622943443762e-11,0.23780505783233014,290.9530814429537,4.297942002643689,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M325H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,300.6,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M325H7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,300.6,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M325H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,325.0,300.6,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K330P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,330.0,304.1,1.71,,,60.0,10.52,40.34,9.88,33.4,0.006312,-0.12372278,45.58,1.6018247895295425,10.529422373589043,1.1969951030769485e-10,0.21054688432784707,235.07381512890473,7.471920877319677,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M330B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,297.5,1.9403519999999999,1.956,0.992,72.0,9.32,45.92,8.85,37.38,0.006524000000000001,-0.16990400000000003,43.6,2.0807105300034636,9.37882969542741,2.440814454193783e-09,0.2888902532535144,999999.9847187275,14.478588083684686,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M330B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,297.5,1.9403519999999999,1.956,0.992,72.0,9.32,45.92,8.85,37.38,0.006524000000000001,-0.16990400000000003,43.6,2.0807105300034636,9.37882969542741,2.440814454193783e-09,0.2888902532535144,999999.9847187275,14.478588083684686,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M330E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,295.3,1.9403519999999999,1.956,0.992,72.0,9.32,45.92,8.85,37.38,0.00466,-0.16072,47.51,1.9266278494997626,9.344209077720034,4.1629026505564977e-10,0.3250200052121677,999999.9847773209,5.109812020561379,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M330E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,295.3,1.9403519999999999,1.956,0.992,72.0,9.32,45.92,8.85,37.38,0.00466,-0.16072,47.51,1.9266278494997626,9.344209077720034,4.1629026505564977e-10,0.3250200052121677,999999.9847773209,5.109812020561379,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M330H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,301.8,1.92,,,72.0,9.32,45.92,8.85,37.38,0.0058716,-0.1455664,45.18,1.856286979569046,9.32000379851636,1.68279107908894e-10,0.34204536769643307,839408.8653864345,7.812791339829163,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6P330B4A,United Renewable Energy Co Ltd,Multi-c-Si,0,330.0,301.3,1.9403519999999999,1.956,0.992,72.0,9.28,46.62,8.78,37.68,0.007424,-0.16316999999999998,43.2,2.017364065808142,9.292150538686364,8.547614045208364e-10,0.35226762433960823,999999.9553956134,11.117064646666798,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6P330B4AME,United Renewable Energy Co Ltd,Multi-c-Si,0,330.0,301.3,1.9403519999999999,1.956,0.992,72.0,9.28,46.62,8.78,37.68,0.007424,-0.16316999999999998,43.2,2.017364065808142,9.292150538686364,8.547614045208364e-10,0.35226762433960823,999999.9553956134,11.117064646666798,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K330H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,309.3,1.66,,,60.0,10.56,40.35,10.0,33.51,0.0112992,-0.12912,42.71,1.6341671408277876,10.56272166382599,1.98683224483154e-10,0.1911640330835285,741.7126530092793,6.631953102964857,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K330H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K330H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K330H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,306.6,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.0036432,-0.10844260000000001,46.0,1.4853031656544802,10.356523293773137,1.3784062863815299e-11,0.23350649383129052,370.486492842027,4.16027778531454,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K330H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,306.6,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.0036432,-0.10844260000000001,46.0,1.4853031656544802,10.356523293773137,1.3784062863815299e-11,0.23350649383129052,370.486492842027,4.16027778531454,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M330H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.4,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M330H7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.4,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M330H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.4,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E330H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,330.0,301.4,1.94,,,72.0,9.26,46.0,8.49,38.9,0.00820436,-0.146556,47.2,1.916219031331843,9.272335188237093,3.32252215689351e-10,0.14527887275563767,109.06054879273822,13.228281965746536,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E330H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,330.0,298.0,1.92,,,72.0,9.25,46.7,8.7,37.95,0.0062900000000000005,-0.17279,46.1,1.9889047727757048,9.254865174808199,5.828827565846847e-10,0.33621913788620783,639.2428934700628,2.0289629728293312,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K330H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K330H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K335P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,335.0,308.8,1.71,,,60.0,10.63,40.4,10.0,33.5,0.006378,-0.12390679999999998,45.58,1.6041385404070398,10.638169546378013,1.2104126777366786e-10,0.20301389124624888,264.1563747698289,7.472554975172108,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M335B4A,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,302.2,1.9403519999999999,1.956,0.992,72.0,9.41,46.04,8.96,37.47,0.006587000000000001,-0.170348,43.6,2.0960237149295975,9.410002902264667,2.7172833892047944e-09,0.2452336460859335,796617.3849051598,15.453479788509538,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M335B4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,302.2,1.9403519999999999,1.956,0.992,72.0,9.41,46.04,8.96,37.47,0.006587000000000001,-0.170348,43.6,2.0960237149295975,9.410002902264667,2.7172833892047944e-09,0.2452336460859335,796617.3849051598,15.453479788509538,-0.52,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M335E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,299.9,1.9403519999999999,1.956,0.992,72.0,9.41,46.04,8.96,37.47,0.004705000000000001,-0.16113999999999998,47.51,1.936639698495074,9.410002818078407,4.457030515693828e-10,0.29932143058537414,999999.9473166078,5.629217247692422,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M335E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,299.9,1.9403519999999999,1.956,0.992,72.0,9.41,46.04,8.96,37.47,0.004705000000000001,-0.16113999999999998,47.51,1.936639698495074,9.410002818078407,4.457030515693828e-10,0.29932143058537414,999999.9473166078,5.629217247692422,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M335H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,306.5,1.92,,,72.0,9.41,46.04,8.96,37.47,0.0059283,-0.1459468,45.18,1.8633743695741332,9.410003051282548,1.750244663539524e-10,0.3241822453232725,999999.8410402907,8.071603972960604,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K335H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,314.1,1.66,,,60.0,10.67,40.38,10.1,33.56,0.0114169,-0.12921600000000003,42.71,1.6364150523447243,10.673015721562944,2.0379094195687557e-10,0.18638111703843385,659.4398040716794,6.76397014387207,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K335H3G,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,310.5,1.6626506,,,60.0,10.41,41.2,9.86,34.0,0.00413277,-0.10955080000000002,45.5,1.550330407922102,10.415238841369867,2.970316332019816e-11,0.24806821503615692,492.93154694445747,11.213345460746005,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K335H3G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,310.5,1.6626506,,,60.0,10.41,41.2,9.86,34.0,0.00413277,-0.10955080000000002,45.5,1.550330407922102,10.415238841369867,2.970316332019816e-11,0.24806821503615692,492.93154694445747,11.213345460746005,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K335H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,311.4,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0036678400000000003,-0.1089768,46.0,1.4916704712639977,10.424707889486557,1.3675037155016914e-11,0.22928073147299358,507.46842156262517,4.026101173018075,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K335H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,311.4,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0036678400000000003,-0.1089768,46.0,1.4916704712639977,10.424707889486557,1.3675037155016914e-11,0.22928073147299358,507.46842156262517,4.026101173018075,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M335H7G,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,310.1,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M335H7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,310.1,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M335H7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,335.0,310.1,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E335H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,335.0,306.1,1.94,,,72.0,9.33,46.2,8.54,39.3,0.00826638,-0.1471932,47.2,1.9328750025379904,9.340128251141541,3.7027773179603597e-10,0.11258278764267804,103.70965547202684,14.168649832073225,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E335H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,335.0,302.7,1.92,,,72.0,9.3,46.8,8.8,38.1,0.0063240000000000015,-0.17315999999999998,46.1,1.9887712711777545,9.30026824023701,5.603165869187598e-10,0.32658586451689137,11322.95097650616,1.6397161974037777,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K340P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,340.0,313.6,1.71,,,60.0,10.74,40.46,10.12,33.6,0.006444,-0.12409081999999999,45.58,1.6064761782325996,10.746978336551306,1.2242585722013764e-10,0.19565179813094943,301.1176655020564,7.476184603495094,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M340E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,304.5,1.9403519999999999,1.956,0.992,72.0,9.48,46.16,9.06,37.57,0.004740000000000001,-0.16155999999999998,47.51,1.9451812795045265,9.48000264583746,4.686071438427058e-10,0.27895346366327867,999999.1322230198,5.993947961453179,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M340E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,304.5,1.9403519999999999,1.956,0.992,72.0,9.48,46.16,9.06,37.57,0.004740000000000001,-0.16155999999999998,47.51,1.9451812795045265,9.48000264583746,4.686071438427058e-10,0.27895346366327867,999999.1322230198,5.993947961453179,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M340H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,311.2,1.92,,,72.0,9.48,46.16,9.06,37.57,0.005972400000000001,-0.1463272,45.18,1.8714945362105349,9.4800028854683,1.8408938089177446e-10,0.30430275589352695,999999.2147812259,8.448279185241262,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K340H7A,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,318.9,1.66,,,60.0,10.9,40.45,10.3,33.7,0.011663,-0.12944,42.71,1.6429499037009239,10.904123906357782,2.1957191048845894e-10,0.17326188703465933,457.9528720096979,7.234173963061805,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K340E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,316.2,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0037030400000000003,-0.10951100000000001,46.0,1.5000754629857609,10.525095002328262,1.4074691801651124e-11,0.22429505419933127,463.11735364585354,4.1911968749579716,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K340E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,316.2,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0037030400000000003,-0.10951100000000001,46.0,1.5000754629857609,10.525095002328262,1.4074691801651124e-11,0.22429505419933127,463.11735364585354,4.1911968749579716,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M340E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,314.9,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M340E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,314.9,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M340E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,314.9,1.68,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E340H4A,United Renewable Energy Co Ltd,Multi-c-Si,0,340.0,310.7,1.94,,,72.0,9.49,46.8,8.86,38.4,0.00840814,-0.14910479999999998,47.2,1.8973954619832145,9.502697249412748,1.8044072065977676e-10,0.3055149508949097,228.3437096062971,7.465913772758023,-0.3844,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E340H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,340.0,309.6,1.92,,,72.0,9.35,46.9,8.9,38.25,0.0051425,-0.160398,45.3,1.9364473735230856,9.350002916189851,2.8337832548909845e-10,0.3117852060504131,999999.8917190378,4.232262737416842,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K340H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,340.0,309.7,1.94,,,72.0,9.35,46.3,8.61,39.5,0.0065637,-0.1392241,47.8,1.8998084145184593,9.358499699948103,2.336629814861107e-10,0.10796823376463661,118.76925198978074,16.79523440867516,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K345P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,345.0,318.3,1.71,,,60.0,10.85,40.52,10.24,33.7,0.006509999999999999,-0.12427484000000001,45.58,1.6088367380207536,10.85584774064443,1.2385278651541615e-10,0.18845493639450214,349.66256510783865,7.482675906477455,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L345L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,345.0,319.5,1.99,,,72.0,9.7,46.96,9.08,37.97,0.007080999999999999,-0.14712568,42.535,1.9173040904451841,9.71163533230722,2.2043920913130085e-10,0.36542480741534383,304.6428575867681,11.06934629966414,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L345L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,320.7,1.99,,,72.0,9.7,46.96,9.08,37.97,0.00679,-0.10955768,41.08,1.8976356802476655,9.712230624497092,1.7092185044117436e-10,0.36994327069350286,293.39871720496336,46.63966900639544,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M345E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,309.1,1.9403519999999999,1.956,0.992,72.0,9.51,46.61,9.09,37.96,0.0047550000000000005,-0.163135,47.51,1.9648716136324706,9.510002637504071,4.742377110517687e-10,0.27719892809305485,999999.1169156822,6.069144505022447,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M345E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,309.1,1.9403519999999999,1.956,0.992,72.0,9.51,46.61,9.09,37.96,0.0047550000000000005,-0.163135,47.51,1.9648716136324706,9.510002637504071,4.742377110517687e-10,0.27719892809305485,999999.1169156822,6.069144505022447,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M345H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,315.9,1.92,,,72.0,9.51,46.61,9.09,37.96,0.005991300000000001,-0.14775370000000002,45.18,1.8904151583099011,9.51000287986467,1.8630789838734458e-10,0.3027543647219309,999999.1426658651,8.525551492556318,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F2K345E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,321.0,1.681248,,,60.0,10.69,41.2,10.06,34.3,0.00376288,-0.11004520000000001,46.0,1.5139648725580341,10.701083665498308,1.595095835029606e-11,0.21738028389039898,209.65945312218443,5.152786144849423,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K345E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,321.0,1.681248,,,60.0,10.69,41.2,10.06,34.3,0.00376288,-0.11004520000000001,46.0,1.5139648725580341,10.701083665498308,1.595095835029606e-11,0.21738028389039898,209.65945312218443,5.152786144849423,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6E345H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,345.0,314.3,1.92,,,72.0,9.4,47.0,8.95,38.55,0.00517,-0.16074000000000002,45.3,1.946063300038667,9.400002663768918,3.050283745851138e-10,0.28327749742855074,999999.2062428653,4.80816955877854,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K345H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,345.0,314.4,1.94,,,72.0,9.42,46.5,8.65,39.9,0.00661284,-0.13982550000000002,47.8,1.9171953944370026,9.426529648875578,2.6351911822127103e-10,0.07566315262528764,109.15547283250477,17.880643037622118,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K350P7A,United Renewable Energy Co Ltd,Mono-c-Si,1,350.0,323.1,1.71,,,60.0,10.96,40.58,10.36,33.8,0.006576000000000001,-0.12445885999999999,45.58,1.611219305289255,10.964776784870962,1.2532162020265394e-10,0.1814178819397262,416.2506861872085,7.491902095628984,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L350L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,350.0,324.2,1.99,,,72.0,9.77,47.06,9.18,38.13,0.007132099999999999,-0.14743898000000003,42.535,1.919913000466957,9.77813356403304,2.188194902957933e-10,0.35361465092738703,424.76035789402533,10.925797436002341,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L350L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,350.0,325.4,1.99,,,72.0,9.77,47.06,9.18,38.13,0.0068390000000000005,-0.10979098000000001,41.08,1.900328709571619,9.778675699219258,1.698782214961781e-10,0.35806829688798064,403.23292718544616,46.46262938370789,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M350E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,350.0,313.6,1.9403519999999999,1.956,0.992,72.0,9.54,46.89,9.13,38.34,0.0073457999999999996,-0.1720863,45.92,2.109485739902022,9.540002000232322,2.118245683924877e-09,0.20931744377743097,999998.2875043474,13.85207565977513,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M350E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,350.0,313.6,1.9403519999999999,1.956,0.992,72.0,9.54,46.89,9.13,38.34,0.0073457999999999996,-0.1720863,45.92,2.109485739902022,9.540002000232322,2.118245683924877e-09,0.20931744377743097,999998.2875043474,13.85207565977513,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M350H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,350.0,320.7,1.92,,,72.0,9.54,46.89,9.13,38.34,0.0060102,-0.1486413,45.18,1.90637698272885,9.540002665422213,1.983663632396986e-10,0.27933056944107587,999998.410629316,9.048885262328742,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6E350H4F,United Renewable Energy Co Ltd,Multi-c-Si,0,350.0,319.0,1.92,,,72.0,9.45,47.1,9.0,38.9,0.0051975,-0.16108200000000003,45.3,1.956872767133952,9.450002355103615,3.329579197927564e-10,0.2491219492569595,999999.9418639019,5.5066658239453945,-0.438,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K350H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,350.0,319.1,1.94,,,72.0,9.62,47.3,9.16,38.3,0.00675324,-0.1422311,47.8,1.858495494423199,9.620003518013464,8.512892727941938e-11,0.3656479008027405,999999.9420192064,7.2537509413880805,-0.388,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K350H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,350.0,320.7,1.92,,,72.0,9.6,47.35,9.1,38.5,0.006144,-0.1519935,45.3,1.9104898483667188,9.60072163697142,1.6526934305351474e-10,0.3488730728811256,4641.094012252014,6.040586977953457,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L355L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,355.0,329.0,1.99,,,72.0,9.84,47.16,9.27,38.26,0.0071832,-0.14775227999999999,42.535,1.9227946608708353,9.84579260609839,2.176911342491318e-10,0.3457750728585186,587.3741890763756,10.80635100428196,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L355L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,330.2,1.99,,,72.0,9.84,47.16,9.27,38.26,0.006888000000000001,-0.11002427999999999,41.08,1.9032769736130863,9.84629953601835,1.6918703486791413e-10,0.3501723226516749,546.9761768537037,46.3162085494148,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M355E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,318.3,1.9403519999999999,1.956,0.992,72.0,9.7,47.16,9.19,38.63,0.007468999999999999,-0.1730772,45.92,2.109796282424639,9.72538846813273,1.9062382224856146e-09,0.2625123892067407,999999.9855496145,12.698259513958924,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M355E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,318.3,1.9403519999999999,1.956,0.992,72.0,9.7,47.16,9.19,38.63,0.007468999999999999,-0.1730772,45.92,2.109796282424639,9.72538846813273,1.9062382224856146e-09,0.2625123892067407,999999.9855496145,12.698259513958924,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M355H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,325.4,1.92,,,72.0,9.7,47.16,9.19,38.63,0.006110999999999999,-0.1494972,45.18,1.9136672739719487,9.701536960111923,1.9190709849121066e-10,0.3070586736963642,1937.8970265614246,8.619252986625531,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K355H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,323.8,1.94,,,72.0,9.69,47.5,9.19,38.7,0.00680238,-0.14283250000000003,47.8,1.868352685234905,9.690008039919704,8.811468539566771e-11,0.3481703115919678,419650.7496868722,7.490245112029016,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K355H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,325.4,1.92,,,72.0,9.65,47.45,9.18,38.7,0.006176,-0.15231450000000002,45.3,1.9188739571874711,9.650003102865117,1.7590256786860747e-10,0.32146533243075587,999999.9301472781,6.528191691150215,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6M355E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M355E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M355E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM355E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.829752,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM355E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.829752,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM355E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,355.0,329.1,1.829752,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L360L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,360.0,333.7,1.99,,,72.0,9.91,47.26,9.37,38.43,0.0072343,-0.14806558,42.535,1.9257822462191974,9.91263076606517,2.170976876695528e-10,0.33312918373318695,1254.8859792656663,10.70587395675113,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L360L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,335.0,1.99,,,72.0,9.91,47.26,9.37,38.43,0.006937000000000001,-0.11025758,41.08,1.9063071964960814,9.913085688935176,1.6886188175531159e-10,0.3374743351139503,1083.8313258852988,46.190888515593045,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M360E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,322.9,1.9403519999999999,1.956,0.992,72.0,9.77,47.44,9.23,39.01,0.0075229,-0.1741048,45.92,2.127821165477737,9.770374258195261,2.0273900652763434e-09,0.24335661761282212,6352.886528963413,13.225357383491929,-0.497,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M360E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,322.9,1.9403519999999999,1.956,0.992,72.0,9.77,47.44,9.23,39.01,0.0075229,-0.1741048,45.92,2.127821165477737,9.770374258195261,2.0273900652763434e-09,0.24335661761282212,6352.886528963413,13.225357383491929,-0.497,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M360H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,330.1,1.92,,,72.0,9.77,47.44,9.23,39.01,0.0061551,-0.15038479999999999,45.18,1.9320017992203093,9.77376577118807,2.1047077945159643e-10,0.28728294157221346,745.333348852882,9.381024182936097,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K360H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,336.7,1.98,,,72.0,9.99,47.4,9.4,38.34,0.0106893,-0.15168,42.71,1.8976751782320451,9.997943482438831,1.4047862604102726e-10,0.363876950324007,457.62436486411417,4.145245220599852,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K360H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,328.5,1.94,,,72.0,9.76,47.7,9.23,39.1,0.006851520000000001,-0.14343390000000003,47.8,1.8878723917071514,9.76403273185919,1.0321252398474664e-10,0.3164985266731582,765.9884302571787,8.830078038024562,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K360H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,330.1,1.92,,,72.0,9.7,47.65,9.26,38.9,0.006207999999999999,-0.1529565,45.3,1.9309718186445695,9.700002909750864,1.8613063149523633e-10,0.29990684702406406,999999.7424896485,6.970925289994856,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6L360L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,360.0,337.5,1.992008,,,72.0,9.68,47.7,9.18,39.2,0.00375584,-0.12859920000000002,42.3,1.7714211658180963,9.684335002481388,1.9440771650132682e-11,0.33398558939041434,745.7851741990555,6.615704837481878,-0.3614,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6L360L4G,United Renewable Energy Co Ltd,Mono-c-Si,1,360.0,335.8,1.99,,,72.0,9.68,47.7,9.18,39.2,0.0031556799999999997,-0.1269297,43.8,1.75337668571824,9.684748836244431,1.472806128667323e-11,0.3382822754920748,689.5526216940445,5.709477017996668,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360H4A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M360H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK360E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.6,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK360E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.6,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM360E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.829752,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM360E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.829752,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM360E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,360.0,333.9,1.829752,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L365L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,365.0,338.5,1.99,,,72.0,9.98,47.36,9.47,38.57,0.007285399999999999,-0.14837888000000002,42.535,1.928790054463269,9.980004392388485,2.1644677603319058e-10,0.32428859608360266,736978.2569410311,10.604936248203169,-0.4167,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L365L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.7,1.99,,,72.0,9.98,47.36,9.47,38.57,0.006986000000000001,-0.11049088000000001,41.08,1.9086472345564127,9.980020788448398,1.670328528960851e-10,0.3287184533723018,157815.07836807752,45.959922069079184,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M365E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,327.6,1.9403519999999999,1.956,0.992,72.0,9.84,47.67,9.27,39.38,0.0075768,-0.1749489,45.92,2.147410158984826,9.842150209888715,2.2395209553874716e-09,0.21898460474173181,1002.1404884181171,14.09653972508668,-0.497,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M365E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,327.6,1.9403519999999999,1.956,0.992,72.0,9.84,47.67,9.27,39.38,0.0075768,-0.1749489,45.92,2.147410158984826,9.842150209888715,2.2395209553874716e-09,0.21898460474173181,1002.1404884181171,14.09653972508668,-0.497,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6M365H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,334.8,1.92,,,72.0,9.84,47.67,9.27,39.38,0.0061992,-0.1511139,45.18,1.9492147768704386,9.845619696838133,2.3310612479313985e-10,0.2634306444612075,461.2629319156929,10.236193085995108,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K365H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,341.5,1.98,,,72.0,10.02,47.59,9.44,38.68,0.010721399999999999,-0.152288,42.71,1.9092795726510239,10.02670271207008,1.4860478050677042e-10,0.341136784592005,509.9712968505925,4.59544142641151,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K365H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,333.2,1.94,,,72.0,9.83,47.9,9.26,39.5,0.006900659999999999,-0.1440353,47.8,1.9057341386942825,9.836837496168725,1.179842401318684e-10,0.2855220209326598,410.48383169636617,9.96745510422436,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K365H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,334.9,1.92,,,72.0,9.75,47.85,9.34,39.1,0.006240000000000001,-0.15359850000000003,45.3,1.9430818924192046,9.7500027068677,1.9685275527880256e-10,0.2775652293972695,999995.9250805007,7.411315746941157,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6L365L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,365.0,342.3,1.992008,,,72.0,9.72,47.9,9.25,39.5,0.0037713600000000005,-0.1291384,42.3,1.7790260731370426,9.721638090604015,1.964671190848897e-11,0.3172302228741839,1882.360931591454,6.657052478176817,-0.3614,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6L365L4G,United Renewable Energy Co Ltd,Mono-c-Si,1,365.0,340.6,1.99,,,72.0,9.72,47.9,9.25,39.5,0.00316872,-0.1274619,43.8,1.7608969221362214,9.72200059615587,1.488281251405169e-11,0.32152217580050313,1562.1321938137003,5.749352111334836,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365H4A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M365H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK365E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.3,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK365E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.3,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM365E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.829752,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM365E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.829752,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM365E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,365.0,338.6,1.829752,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L370L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,370.0,343.2,1.99,,,72.0,10.06,47.46,9.56,38.72,0.0073438,-0.14869218,42.535,1.9340242345947973,10.077628951301747,2.2181153083380927e-10,0.3136081398035496,999999.9856262287,10.738537251631202,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L370L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.5,1.99,,,72.0,10.06,47.46,9.56,38.72,0.007042000000000001,-0.11072418,41.08,1.914102226715985,10.072907653756015,1.7173487531863976e-10,0.3180540593371871,999999.9856112666,46.179471233343655,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M370E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,332.2,1.9403519999999999,1.956,0.992,72.0,9.89,47.81,9.41,39.4,0.0076153,-0.1754627,45.92,2.1454452622148596,9.952264147571473,2.088910532849532e-09,0.23028955199946516,999999.9860461369,13.334220193323322,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M370E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,332.2,1.9403519999999999,1.956,0.992,72.0,9.89,47.81,9.41,39.4,0.0076153,-0.1754627,45.92,2.1454452622148596,9.952264147571473,2.088910532849532e-09,0.23028955199946516,999999.9860461369,13.334220193323322,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M370H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,339.5,1.92,,,72.0,9.89,47.81,9.41,39.4,0.0062307000000000005,-0.15155770000000002,45.18,1.9454602838949198,9.890003770871997,2.100567640618691e-10,0.2755793451066089,722894.9260778412,9.23604624872867,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K370H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,346.2,1.98,,,72.0,10.05,47.77,9.48,39.02,0.010753500000000001,-0.152864,42.71,1.9206687796432238,10.055563429441802,1.574780220420202e-10,0.31754258173892164,573.621606124884,5.062717760502231,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K370H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,337.9,1.94,,,72.0,9.9,48.1,9.3,39.9,0.0069498,-0.14463670000000003,47.8,1.9226185930305537,9.908243517152869,1.3301203391317262e-10,0.2548894407199848,306.107881732233,10.98823526593854,-0.388,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K370H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,342.6,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.00329305,-0.1300143,45.8,1.7825835461248614,9.832051811597243,1.8731392619518233e-11,0.32361889961090945,1550.4220312363548,5.944855852464915,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K370H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,339.6,1.92,,,72.0,9.8,48.05,9.42,39.3,0.006272000000000001,-0.1542405,45.3,1.9558801641964194,9.800219952371036,2.097769507703794e-10,0.2522535103388267,11239.207559088674,7.92116282496712,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K370H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,342.6,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.00329305,-0.1300143,45.8,1.7825835461248614,9.832051811597243,1.8731392619518233e-11,0.32361889961090945,1550.4220312363548,5.944855852464915,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K370H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,342.6,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.00329305,-0.1300143,45.8,1.7825835461248614,9.832051811597243,1.8731392619518233e-11,0.32361889961090945,1550.4220312363548,5.944855852464915,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6L370L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,370.0,347.1,1.992008,,,72.0,9.79,48.2,9.32,39.7,0.0037985199999999997,-0.1299472,42.3,1.786203488196039,9.790007068370828,1.8685817732313896e-11,0.32335398383561914,447865.06719114364,6.154309261811038,-0.3614,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6L370L4G,United Renewable Energy Co Ltd,Mono-c-Si,1,370.0,345.3,1.99,,,72.0,9.79,48.2,9.32,39.7,0.0031915399999999992,-0.12826020000000002,43.8,1.7673290987083512,9.790007185335138,1.4007314567221396e-11,0.3277728308729297,446594.0889380231,5.159063741778002,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370H4A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M370H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK370E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.1,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK370E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.1,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM370E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.829752,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM370E7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.829752,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM370E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,370.0,343.4,1.829752,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L375L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,375.0,348.0,1.99,,,72.0,10.13,47.56,9.66,38.87,0.0073949,-0.14900548000000002,42.535,1.9445924092966569,10.130002852026902,2.420031100549853e-10,0.281462819078601,999999.6904076366,11.473789458782006,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L375L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.3,1.99,,,72.0,10.13,47.56,9.66,38.87,0.007091000000000002,-0.11095748000000001,41.08,1.9233530605863929,10.130002920314888,1.8472508778647832e-10,0.28821412253767426,999992.3640007376,46.97715529857483,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M375E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,336.9,1.9403519999999999,1.956,0.992,72.0,9.95,47.93,9.51,39.45,0.007661499999999999,-0.1759031,45.92,2.161920277183045,9.950001821242411,2.341352010216039e-09,0.1827290647772126,999999.6486879823,14.394788676619537,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M375E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,336.9,1.9403519999999999,1.956,0.992,72.0,9.95,47.93,9.51,39.45,0.007661499999999999,-0.1759031,45.92,2.161920277183045,9.950001821242411,2.341352010216039e-09,0.1827290647772126,999999.6486879823,14.394788676619537,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M375H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,344.3,1.92,,,72.0,9.95,47.93,9.51,39.45,0.0062685,-0.1519381,45.18,1.9534424438873077,9.950002498973094,2.197338401438447e-10,0.25109571677019515,999999.6727513005,9.58059497133747,-0.417,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K375H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,351.0,1.98,,,72.0,10.08,47.96,9.53,39.37,0.0107856,-0.15347200000000003,42.71,1.9314230604721727,10.083709262050954,1.6476864000827267e-10,0.29412958148877155,799.3036405277608,5.419491139585466,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K375H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,347.3,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.0033232,-0.1305549,45.8,1.7912998165493903,9.922583580821144,1.926279178157259e-11,0.31767762796775906,1219.7648499848483,6.109514590274358,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K375H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,347.3,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.0033232,-0.1305549,45.8,1.7912998165493903,9.922583580821144,1.926279178157259e-11,0.31767762796775906,1219.7648499848483,6.109514590274358,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K375H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,348.2,1.92,,,72.0,9.85,48.25,9.5,39.5,0.00788,-0.1433025,44.8,1.8961184057583205,9.850123822601152,8.749590333779091e-11,0.3239703790324379,25771.69515868772,8.515176334477433,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K375H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,347.3,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.0033232,-0.1305549,45.8,1.7912998165493903,9.922583580821144,1.926279178157259e-11,0.31767762796775906,1219.7648499848483,6.109514590274358,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K375H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,347.3,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.0033232,-0.1305549,45.8,1.7912998165493903,9.922583580821144,1.926279178157259e-11,0.31767762796775906,1219.7648499848483,6.109514590274358,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6L375L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,375.0,351.9,1.992008,,,72.0,9.85,48.5,9.4,39.9,0.0038218,-0.130756,42.3,1.7982664117797391,9.850004384956694,1.90690492517141e-11,0.3283925101564791,737689.6032344735,6.276275129713467,-0.3614,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6L375L4G,United Renewable Energy Co Ltd,Mono-c-Si,1,375.0,350.1,1.99,,,72.0,9.85,48.5,9.4,39.9,0.0032110999999999997,-0.1290585,43.8,1.779304242638775,9.850004448586068,1.430545482799251e-11,0.33278271921562674,736855.5929858502,5.286446666037689,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M375H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M375H4A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M375H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M375H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M375H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M375H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K375H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,346.9,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0035200000000000006,-0.123802,44.3,1.8403704061538573,10.00428728261265,5.2114750949449136e-11,0.27218043799176433,634.855393948642,19.93169112516487,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K375H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,346.9,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0035200000000000006,-0.123802,44.3,1.8403704061538573,10.00428728261265,5.2114750949449136e-11,0.27218043799176433,634.855393948642,19.93169112516487,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M375H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M375H8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M375H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK375E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,347.9,1.83,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK375E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,375.0,347.9,1.83,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L380L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,380.0,352.8,1.99,,,72.0,10.21,47.66,9.75,39.02,0.0074533,-0.14931878,42.535,1.9515413419809038,10.210002713238033,2.5281611597324305e-10,0.26566846592252,999999.7386298275,11.797670907211936,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L380L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,354.0,1.99,,,72.0,10.21,47.66,9.75,39.02,0.0071470000000000014,-0.11119078,41.08,1.9298967680627492,10.210002783359949,1.9224352235982179e-10,0.27255027837928447,999999.7393958437,47.35892665830649,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M380E4A,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,341.6,1.9403519999999999,1.956,0.992,72.0,10.11,48.06,9.61,39.55,0.007784699999999999,-0.17638020000000001,45.92,2.155113152799176,10.165196269994635,2.0996647029750668e-09,0.23351350388979872,999999.9861323425,13.184918731122723,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M380E4AME,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,341.6,1.9403519999999999,1.956,0.992,72.0,10.11,48.06,9.61,39.55,0.007784699999999999,-0.17638020000000001,45.92,2.155113152799176,10.165196269994635,2.0996647029750668e-09,0.23351350388979872,999999.9861323425,13.184918731122723,-0.497,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6M380H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,349.0,1.92,,,72.0,10.11,48.06,9.61,39.55,0.0063693,-0.15235020000000002,45.18,1.9535238448219516,10.110004025027017,2.0910648437615744e-10,0.27798907839085607,698365.2720049381,9.002190842046385,-0.417,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K380H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,355.8,1.98,,,72.0,10.1,48.15,9.57,39.71,0.010806999999999999,-0.15408,42.71,1.936965533328236,10.100005965421056,1.615923214108111e-10,0.27346771007274956,463045.34540081973,5.220971630430682,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1L380O4G,United Renewable Energy Co Ltd,Mono-c-Si,1,380.0,354.9,1.99,,,72.0,9.94,48.8,9.46,40.2,0.00324044,-0.1298568,43.8,1.7892102038277642,9.94000714996007,1.4196194125987256e-11,0.3262342364345687,453539.2695784441,5.143638452280042,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K380H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,352.1,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.00335335,-0.13109549999999998,45.8,1.8000140046246078,10.013099647262754,1.9803509057510975e-11,0.31183748503709674,1007.0479063479752,6.272566077752904,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K380H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,352.1,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.00335335,-0.13109549999999998,45.8,1.8000140046246078,10.013099647262754,1.9803509057510975e-11,0.31183748503709674,1007.0479063479752,6.272566077752904,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K380H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,353.0,1.92,,,72.0,9.9,48.45,9.58,39.7,0.00792,-0.1438965,44.8,1.910211710240003,9.900160005005539,9.55398374349095e-11,0.22734397375467494,14066.487173360772,9.247233648932182,-0.371,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K380H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,352.1,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.00335335,-0.13109549999999998,45.8,1.8000140046246078,10.013099647262754,1.9803509057510975e-11,0.31183748503709674,1007.0479063479752,6.272566077752904,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K380H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,352.1,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.00335335,-0.13109549999999998,45.8,1.8000140046246078,10.013099647262754,1.9803509057510975e-11,0.31183748503709674,1007.0479063479752,6.272566077752904,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M380H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,353.9,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.0039139100000000005,-0.13095,44.5,1.8069803318357311,10.012953755314742,2.1975417620131488e-11,0.31023590780625065,1051.3604587735836,7.215272391952535,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M380H4A-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,353.9,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.0039139100000000005,-0.13095,44.5,1.8069803318357311,10.012953755314742,2.1975417620131488e-11,0.31023590780625065,1051.3604587735836,7.215272391952535,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M380H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,353.9,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.0039139100000000005,-0.13095,44.5,1.8069803318357311,10.012953755314742,2.1975417620131488e-11,0.31023590780625065,1051.3604587735836,7.215272391952535,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M380H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,349.5,1.968096,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M380H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,349.5,1.968096,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M380H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,349.5,1.968096,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K380H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035411200000000005,-0.12457900000000001,44.3,1.8528489333641933,10.06405444318326,5.3127904276577706e-11,0.266048689514278,660.127620280329,20.058810123472938,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K380H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035411200000000005,-0.12457900000000001,44.3,1.8528489333641933,10.06405444318326,5.3127904276577706e-11,0.266048689514278,660.127620280329,20.058810123472938,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M380H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M380H8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M380H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK380E7G,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,352.7,1.83,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK380E7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,380.0,352.7,1.83,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L385L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,385.0,357.5,1.99,,,72.0,10.28,47.76,9.85,39.17,0.0075044,-0.14963208,42.535,1.960312071459098,10.280002471508087,2.698184124580822e-10,0.24035189025168827,999996.4242873659,12.326078098216694,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L385L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,358.8,1.99,,,72.0,10.28,47.76,9.85,39.17,0.007196000000000001,-0.11142408,41.08,1.9380046359132563,10.28000254528114,2.038354560464201e-10,0.24754067478916944,999996.439631781,47.977519447415645,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K385H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,360.6,1.98,,,72.0,10.13,48.34,9.61,40.05,0.0108391,-0.15468800000000002,42.71,1.9533482572361287,10.131424549539277,1.806806685626574e-10,0.2506381671398938,1782.2937990275968,6.162926813165013,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K385H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.0,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K385H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.0,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1L385O4G,United Renewable Energy Co Ltd,Mono-c-Si,1,385.0,359.7,1.99,,,72.0,10.03,49.0,9.53,40.4,0.00326978,-0.130389,43.8,1.80250495986218,10.033347138476286,1.560249218969472e-11,0.3195321732586691,957.5066370870326,5.891980686967847,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M385H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M385H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M385H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K385H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.8,1.9188,,,72.0,10.09,48.7,9.58,40.2,0.00338015,-0.1316361,45.8,1.8087714457612907,10.0936386776344,2.0345893672853914e-11,0.3063963214678578,849.6325513212676,6.439541838018775,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K385H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.8,1.9188,,,72.0,10.09,48.7,9.58,40.2,0.00338015,-0.1316361,45.8,1.8087714457612907,10.0936386776344,2.0345893672853914e-11,0.3063963214678578,849.6325513212676,6.439541838018775,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K385H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,357.7,1.92,,,72.0,9.95,48.65,9.65,39.7,0.00796,-0.1444905,44.8,1.9167420380252707,9.950192066274804,9.431041599320263e-11,0.22982436770607995,11906.07250121219,9.088245900266251,-0.371,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K385H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.0,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K385H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.0,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M385H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M385H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M385H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K385H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00356224,-0.125356,44.3,1.865325586339818,10.123829146069554,5.4147856091863336e-11,0.2599954544828044,687.1386003150868,20.184106080070023,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K385H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00356224,-0.125356,44.3,1.865325586339818,10.123829146069554,5.4147856091863336e-11,0.2599954544828044,687.1386003150868,20.184106080070023,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M385H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M385H8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M385H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K390P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,390.0,359.3,2.03,,,72.0,10.36,48.43,9.74,40.04,0.006215999999999999,-0.14853481,45.58,1.9204830904409607,10.3686972926906,1.1411680328068721e-10,0.26378364849580455,314.2125726424764,7.186308118567978,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D6L390L4A,United Renewable Energy Co Ltd,Mono-c-Si,1,390.0,362.3,1.99,,,72.0,10.36,47.86,9.94,39.32,0.0075628,-0.14994538000000002,42.535,1.9672379557210935,10.360002329261482,2.81587386663895e-10,0.22474210106599335,999873.2043880374,12.644250216445958,-0.4167,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D6L390L4A-P,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,363.6,1.99,,,72.0,10.36,47.86,9.94,39.32,0.007252000000000001,-0.11165738000000001,41.08,1.9445140776947922,10.36000240510768,2.1190458401724643e-10,0.2320703040668544,999857.9455981946,48.350425437189436,-0.4333,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd D7K390H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,365.4,1.98,,,72.0,10.16,48.53,9.66,40.39,0.010871200000000001,-0.15529600000000002,42.71,1.9636952577839024,10.160189012414023,1.8782294592006192e-10,0.22918920366462406,12319.654054169367,6.46704200466608,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K390H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,360.7,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K390H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,360.7,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1L390O4G,United Renewable Energy Co Ltd,Mono-c-Si,1,390.0,364.5,1.99,,,72.0,10.11,49.3,9.61,40.6,0.0032958599999999994,-0.1311873,43.8,1.8121311060635106,10.113005149072462,1.5407163303438524e-11,0.3246264701179815,1092.1163467986844,5.713718096467374,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M390H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M390H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M390H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K390H4A,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.6,1.9188,,,72.0,10.18,48.9,9.66,40.4,0.0034103000000000002,-0.13217669999999998,45.8,1.8174820484967815,10.184123284459243,2.0905414197354613e-11,0.3007423300355358,742.5044325925267,6.599491144285145,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K390H4A-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.6,1.9188,,,72.0,10.18,48.9,9.66,40.4,0.0034103000000000002,-0.13217669999999998,45.8,1.8174820484967815,10.184123284459243,2.0905414197354613e-11,0.3007423300355358,742.5044325925267,6.599491144285145,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K390H4F,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,362.5,1.92,,,72.0,10.0,48.85,9.73,40.1,0.008,-0.1450845,44.8,1.9327786516827243,10.000127038339935,1.0550738214119642e-10,0.1797777218178315,14151.470485948283,10.03980723132376,-0.371,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd F6K390H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,360.7,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K390H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,360.7,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M390H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M390H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M390H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K390H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.003597440000000001,-0.125615,44.3,1.8593275438544012,10.220004579511636,4.7974062814489926e-11,0.2581122665961081,576042.6087871741,18.89679258881582,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K390H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.003597440000000001,-0.125615,44.3,1.8593275438544012,10.220004579511636,4.7974062814489926e-11,0.2581122665961081,576042.6087871741,18.89679258881582,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M390H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M390H8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M390H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM390MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,358.3,1.94,,,108.0,13.5,36.84,12.66,30.82,0.008518500000000002,-0.11479344000000001,45.83,1.4998219104067805,13.510332428734404,2.85251917761413e-10,0.11579955583629135,151.299769221344,11.155789370189236,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM390MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,358.3,1.94,,,54.0,13.5,36.84,12.66,30.82,0.008518500000000002,-0.11479344000000001,45.83,1.4998219104067805,13.510332428734404,2.85251917761413e-10,0.11579955583629135,151.299769221344,11.155789370189236,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM390MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,390.0,358.3,1.94,,,54.0,13.5,36.84,12.66,30.82,0.008518500000000002,-0.11479344000000001,45.83,1.4998219104067805,13.510332428734404,2.85251917761413e-10,0.11579955583629135,151.299769221344,11.155789370189236,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K395P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,395.0,364.1,2.03,,,72.0,10.45,48.44,9.85,40.12,0.0062699999999999995,-0.14856548,45.58,1.9202020467360643,10.45677157093079,1.1441627946341078e-10,0.2534266808660281,391.0922554139934,7.12494739858506,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K395H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,370.2,1.98,,,72.0,10.19,48.72,9.71,40.73,0.0109033,-0.15590400000000001,42.71,1.976620165517858,10.19000320803579,2.0119737054877223e-10,0.20746403136824124,659067.5101618374,7.038260319173004,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K395H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.5,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K395H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.5,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M395H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M395H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1M395H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K395H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K395H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M395H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M395H8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2M395H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K395H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.5,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6K395H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.5,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M395H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M395H4G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F6M395H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K395H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7K395H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M395H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M395H8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F7M395H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM395MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.1,1.94,,,108.0,13.59,37.03,12.75,31.0,0.00857529,-0.11538548,45.83,1.4614591949708724,13.601638152577111,1.321801955202104e-10,0.12162535369676632,142.0232794840813,4.4090406881824205,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM395MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.1,1.94,,,54.0,13.59,37.03,12.75,31.0,0.00857529,-0.11538548,45.83,1.4614591949708724,13.601638152577111,1.321801955202104e-10,0.12162535369676632,142.0232794840813,4.4090406881824205,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM395MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,395.0,363.1,1.94,,,54.0,13.59,37.03,12.75,31.0,0.00857529,-0.11538548,45.83,1.4614591949708724,13.601638152577111,1.321801955202104e-10,0.12162535369676632,142.0232794840813,4.4090406881824205,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K400P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,400.0,368.8,2.03,,,72.0,10.55,48.46,9.95,40.2,0.0063300000000000006,-0.14862682,45.58,1.9220790500840823,10.556320870963537,1.1722762084543188e-10,0.24379085734135747,406.9049228168884,7.250938534894449,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K400H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,375.0,1.98,,,72.0,10.22,48.91,9.76,41.07,0.010935400000000001,-0.15651199999999998,42.71,1.9900600019150552,10.22000291230814,2.166346394817557e-10,0.18587281168338463,652350.5784438014,7.658690597715019,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K400H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,370.2,1.968096,,,72.0,10.35,49.3,9.81,40.8,0.00475065,-0.1327156,46.6,1.8451951318838913,10.354863231731121,2.560095628839045e-11,0.28769900702457224,612.2851941076362,8.500356580606194,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K400H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,370.2,1.968096,,,72.0,10.35,49.3,9.81,40.8,0.00475065,-0.1327156,46.6,1.8451951318838913,10.354863231731121,2.560095628839045e-11,0.28769900702457224,612.2851941076362,8.500356580606194,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K400H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036572800000000006,-0.126651,44.3,1.888111286326416,10.39496441517563,5.822153708655742e-11,0.24570320177805335,514.2310217656832,20.640799378756142,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K400H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036572800000000006,-0.126651,44.3,1.888111286326416,10.39496441517563,5.822153708655742e-11,0.24570320177805335,514.2310217656832,20.640799378756142,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM400MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,367.8,1.94,,,108.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM400MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,367.8,1.94,,,54.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM400MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,400.0,367.8,1.94,,,54.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K405P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,373.6,2.03,,,72.0,10.67,48.47,10.05,40.28,0.006402,-0.14865749,45.58,1.9256499852095172,10.677141290028807,1.2337848073888642e-10,0.23261095281228317,347.5505082216487,7.602048392870741,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K405H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,379.8,1.98,,,72.0,10.25,49.1,9.81,41.41,0.0109675,-0.15712,42.71,2.003491088877512,10.250002610855624,2.3300737484607854e-10,0.16451664407236177,645954.644801736,8.273425168225538,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K405H4G,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,375.0,1.968096,,,72.0,10.43,49.5,9.88,41.0,0.004787370000000001,-0.13325399999999998,46.6,1.8540001772225838,10.43533561437403,2.6273687373196756e-11,0.28258372101983764,552.3915448649208,8.663511168231926,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F1K405H4G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,375.0,1.968096,,,72.0,10.43,49.5,9.88,41.0,0.004787370000000001,-0.13325399999999998,46.6,1.8540001772225838,10.43533561437403,2.6273687373196756e-11,0.28258372101983764,552.3915448649208,8.663511168231926,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K405H8G,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036889600000000002,-0.127169,44.3,1.897121790906059,10.485311894009968,5.972624676154759e-11,0.24060985034767018,474.70663113210384,20.807843969991662,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd F2K405H8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036889600000000002,-0.127169,44.3,1.897121790906059,10.485311894009968,5.972624676154759e-11,0.24060985034767018,474.70663113210384,20.807843969991662,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,381.4,1.95,,,54.0,13.83,37.7,13.07,31.0,0.0055320000000000005,-0.09085700000000001,45.7,1.294382311345,13.845426942002456,3.0585015659473807e-12,0.20148608497063067,180.6289645031725,-0.3249664399288288,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405BFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405BFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405BFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405BFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,381.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.006804360000000001,-0.09058272,45.84,1.3083822467781963,13.8445783766596,4.242830571010351e-12,0.19579775336911664,185.74653510266006,2.526189182697892,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,381.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.006804360000000001,-0.09058272,45.84,1.3083822467781963,13.8445783766596,4.242830571010351e-12,0.19579775336911664,185.74653510266006,2.526189182697892,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF405MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,381.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.006804360000000001,-0.09058272,45.84,1.3083822467781963,13.8445783766596,4.242830571010351e-12,0.19579775336911664,185.74653510266006,2.526189182697892,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM405MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,372.6,1.94,,,108.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM405MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,372.6,1.94,,,54.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM405MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,405.0,372.6,1.94,,,54.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K410P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,378.3,2.03,,,72.0,10.75,48.49,10.16,40.36,0.00645,-0.14871883,45.58,1.9246935178354785,10.754814638527606,1.2196172372539837e-10,0.22424163422820878,500.68093515003,7.424306652940961,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K410H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,384.6,1.98,,,72.0,10.28,49.29,9.86,41.75,0.0109996,-0.157728,42.71,2.0169096728614297,10.280001474359045,2.5034481039498304e-10,0.14339231893436372,999998.747504196,8.882141518420232,-0.367,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.8,13.17,31.1,0.005564,-0.091098,45.7,1.2971059936238414,13.923094568342464,3.033950339498054e-12,0.19929107292679757,211.70142892250567,-0.44696445660781964,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410BFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410BFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410BFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410BFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,386.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00684372,-0.090751,45.84,1.3109837748663669,13.9221895144476,4.29188112352633e-12,0.1896156575549306,216.37890616389151,2.5672999942547468,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,386.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00684372,-0.090751,45.84,1.3109837748663669,13.9221895144476,4.29188112352633e-12,0.1896156575549306,216.37890616389151,2.5672999942547468,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF410MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,386.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00684372,-0.090751,45.84,1.3109837748663669,13.9221895144476,4.29188112352633e-12,0.1896156575549306,216.37890616389151,2.5672999942547468,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM410MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,377.3,1.94,,,108.0,13.86,37.54,13.0,31.55,0.00874566,-0.11697464,45.83,1.532064378073455,13.869496256166432,3.109027227773936e-10,0.10201288068886662,148.89010696622137,11.695069715057826,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM410MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,377.3,1.94,,,54.0,13.86,37.54,13.0,31.55,0.00874566,-0.11697464,45.83,1.532064378073455,13.869496256166432,3.109027227773936e-10,0.10201288068886662,148.89010696622137,11.695069715057826,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM410MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,410.0,377.3,1.94,,,54.0,13.86,37.54,13.0,31.55,0.00874566,-0.11697464,45.83,1.532064378073455,13.869496256166432,3.109027227773936e-10,0.10201288068886662,148.89010696622137,11.695069715057826,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K415P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,383.1,2.03,,,72.0,10.85,48.51,10.26,40.44,0.006509999999999999,-0.14878017,45.58,1.9265971484786453,10.854438594185321,1.249549256534351e-10,0.21517596953131687,525.990736276858,7.552815104989705,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K415H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,415.0,389.4,1.98,,,72.0,10.31,49.48,9.91,42.09,0.0110317,-0.158336,42.71,2.032590591179843,10.310000816913119,2.761135691412415e-10,0.07922157184246778,999997.3829792852,9.728368561909898,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBF415BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,391.0,1.95,,,54.0,13.99,37.9,13.24,31.3,0.005596,-0.091339,45.7,1.3030977052754698,14.003342408279575,3.2284136398297502e-12,0.1885520495777324,197.7036770653836,0.021910402392765087,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,415.0,390.8,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00688308,-0.09115968,45.84,1.3181393070383944,14.002628478547619,4.433312158376842e-12,0.18509336632839893,205.04894479386198,2.796000942090115,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,415.0,390.8,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00688308,-0.09115968,45.84,1.3181393070383944,14.002628478547619,4.433312158376842e-12,0.18509336632839893,205.04894479386198,2.796000942090115,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF415MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,415.0,390.8,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00688308,-0.09115968,45.84,1.3181393070383944,14.002628478547619,4.433312158376842e-12,0.18509336632839893,205.04894479386198,2.796000942090115,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D2K420P8A,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,387.9,2.03,,,72.0,10.95,48.52,10.37,40.52,0.0065699999999999995,-0.14881084,45.58,1.9273650034066827,10.953471654944734,1.2691945236346508e-10,0.2054698917290462,648.0757356503835,7.603399159904464,-0.39,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd D7K420H8A,United Renewable Energy Co Ltd,Mono-c-Si,0,420.0,394.3,1.98,,,72.0,10.34,49.67,9.96,42.43,0.0110638,-0.158944,42.71,2.046536854237595,10.34000049721332,2.979027868278572e-10,0.04807572093969774,999942.7103134656,10.383231279849962,-0.367,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBF420BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,395.8,1.95,,,54.0,14.07,38.1,13.32,31.5,0.005628000000000001,-0.091821,45.7,1.3104704828030997,14.082913961442541,3.2837249327211305e-12,0.18549060445622628,202.0954468931237,0.11426993449319596,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,396.7,1.95,,,54.0,14.07,38.11,13.32,31.52,0.005262180000000001,-0.09051124999999999,45.0,1.3054514900485394,14.083138641418156,2.913389169162552e-12,0.18548593232244637,198.63453646901712,0.6370790849382147,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,396.7,1.95,,,54.0,14.07,38.11,13.32,31.52,0.005262180000000001,-0.09051124999999999,45.0,1.3054514900485394,14.083138641418156,2.913389169162552e-12,0.18548593232244637,198.63453646901712,0.6370790849382147,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,396.7,1.95,,,54.0,14.07,38.11,13.32,31.52,0.005262180000000001,-0.09051124999999999,45.0,1.3054514900485394,14.083138641418156,2.913389169162552e-12,0.18548593232244637,198.63453646901712,0.6370790849382147,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,396.7,1.95,,,54.0,14.07,38.11,13.32,31.52,0.005262180000000001,-0.09051124999999999,45.0,1.3054514900485394,14.083138641418156,2.913389169162552e-12,0.18548593232244637,198.63453646901712,0.6370790849382147,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,420.0,396.7,1.95,,,54.0,14.07,38.11,13.32,31.52,0.005262180000000001,-0.09051124999999999,45.0,1.3054514900485394,14.083138641418156,2.913389169162552e-12,0.18548593232244637,198.63453646901712,0.6370790849382147,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,420.0,395.6,1.95,,,54.0,14.07,38.11,13.32,31.52,0.006922440000000001,-0.09161644,45.84,1.3252146618703597,14.082215658461145,4.505706216054266e-12,0.18213699085437196,209.78545091498472,2.8840493638637255,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,420.0,395.6,1.95,,,54.0,14.07,38.11,13.32,31.52,0.006922440000000001,-0.09161644,45.84,1.3252146618703597,14.082215658461145,4.505706216054266e-12,0.18213699085437196,209.78545091498472,2.8840493638637255,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF420MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,420.0,395.6,1.95,,,54.0,14.07,38.11,13.32,31.52,0.006922440000000001,-0.09161644,45.84,1.3252146618703597,14.082215658461145,4.505706216054266e-12,0.18213699085437196,209.78545091498472,2.8840493638637255,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM425E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,425.0,396.4,2.190284,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM425E8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,425.0,396.4,2.19,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM425E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,425.0,396.4,2.190284,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,400.7,1.95,,,54.0,14.16,38.4,13.4,31.7,0.005664000000000001,-0.092544,45.7,1.3200738502993992,14.173629684310423,3.252067789354092e-12,0.189845143484444,197.23180485447796,-0.01746370229931588,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425BFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425BFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425BFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425BFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,401.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0052958400000000004,-0.0912,45.0,1.3148379078999695,14.173832204068056,2.8956314209343744e-12,0.18909429024610797,193.5754755068789,0.5343728057141575,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,401.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0052958400000000004,-0.0912,45.0,1.3148379078999695,14.173832204068056,2.8956314209343744e-12,0.18909429024610797,193.5754755068789,0.5343728057141575,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,401.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0052958400000000004,-0.0912,45.0,1.3148379078999695,14.173832204068056,2.8956314209343744e-12,0.18909429024610797,193.5754755068789,0.5343728057141575,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,401.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0052958400000000004,-0.0912,45.0,1.3148379078999695,14.173832204068056,2.8956314209343744e-12,0.18909429024610797,193.5754755068789,0.5343728057141575,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,425.0,401.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0052958400000000004,-0.0912,45.0,1.3148379078999695,14.173832204068056,2.8956314209343744e-12,0.18909429024610797,193.5754755068789,0.5343728057141575,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,425.0,400.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.00696672,-0.09231360000000001,45.84,1.3347321061652233,14.17288254498246,4.477988396576517e-12,0.18574610170608657,204.16500073424461,2.778812247252525,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,425.0,400.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.00696672,-0.09231360000000001,45.84,1.3347321061652233,14.17288254498246,4.477988396576517e-12,0.18574610170608657,204.16500073424461,2.778812247252525,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF425MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,425.0,400.5,1.95,,,54.0,14.16,38.4,13.4,31.72,0.00696672,-0.09231360000000001,45.84,1.3347321061652233,14.17288254498246,4.477988396576517e-12,0.18574610170608657,204.16500073424461,2.778812247252525,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK430C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,399.5,2.19,,,144.0,11.2,48.6,10.65,40.4,0.005667199999999999,-0.13617720000000003,45.73,1.8180253111844236,11.20268608795852,2.7401280751950135e-11,0.2433949386125851,1014.867514091067,4.048255497691683,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK430E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,398.9,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK430E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,398.9,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL430A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,400.7,2.2048720000000004,,,72.0,11.2,48.6,10.65,40.4,0.0058464,-0.12864420000000001,46.18,1.7736195709576112,11.203608812022006,1.4014831304133904e-11,0.25259689697451,783.9381137137947,4.3315520029135905,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM430E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,401.2,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM430E8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,401.2,2.19,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM430E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,401.2,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.9,0.005696,-0.09278499999999999,45.7,1.3247553765582678,14.25118500264026,3.3668936342654234e-12,0.1793576474449288,228.3462048657815,0.21641766744719257,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430BFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430BFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430BFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430BFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,406.4,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0053257600000000006,-0.09143749999999999,45.0,1.3189076570938894,14.251466258084077,2.9593716873218536e-12,0.18114839744208838,224.96904965439958,0.66157682022627,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,406.4,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0053257600000000006,-0.09143749999999999,45.0,1.3189076570938894,14.251466258084077,2.9593716873218536e-12,0.18114839744208838,224.96904965439958,0.66157682022627,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,406.4,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0053257600000000006,-0.09143749999999999,45.0,1.3189076570938894,14.251466258084077,2.9593716873218536e-12,0.18114839744208838,224.96904965439958,0.66157682022627,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,406.4,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0053257600000000006,-0.09143749999999999,45.0,1.3189076570938894,14.251466258084077,2.9593716873218536e-12,0.18114839744208838,224.96904965439958,0.66157682022627,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,430.0,406.4,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0053257600000000006,-0.09143749999999999,45.0,1.3189076570938894,14.251466258084077,2.9593716873218536e-12,0.18114839744208838,224.96904965439958,0.66157682022627,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430MFG,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,405.3,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0070060800000000005,-0.092554,45.84,1.3388797889896735,14.250577268499026,4.577193657638088e-12,0.17780656351224983,239.37800863258198,2.910030831934157,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430MFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,405.3,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0070060800000000005,-0.092554,45.84,1.3388797889896735,14.250577268499026,4.577193657638088e-12,0.17780656351224983,239.37800863258198,2.910030831934157,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF430MFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,405.3,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0070060800000000005,-0.092554,45.84,1.3388797889896735,14.250577268499026,4.577193657638088e-12,0.17780656351224983,239.37800863258198,2.910030831934157,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM430M7G,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,395.2,2.15,,,60.0,13.25,41.34,12.54,34.3,0.0058962500000000004,-0.12063012000000002,46.56,1.5921284576770103,13.256235181456885,6.952812262323116e-11,0.17305428512211307,367.74701363432195,6.330491113018672,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM430M7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,395.2,2.15,,,60.0,13.25,41.34,12.54,34.3,0.0058962500000000004,-0.12063012000000002,46.56,1.5921284576770103,13.256235181456885,6.952812262323116e-11,0.17305428512211307,367.74701363432195,6.330491113018672,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM430M7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,430.0,395.2,2.15,,,60.0,13.25,41.34,12.54,34.3,0.0058962500000000004,-0.12063012000000002,46.56,1.5921284576770103,13.256235181456885,6.952812262323116e-11,0.17305428512211307,367.74701363432195,6.330491113018672,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK435C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,404.3,2.19,,,144.0,11.28,48.8,10.72,40.6,0.00570768,-0.1367376,45.73,1.8202240652369313,11.280009835601975,2.5639941656017372e-11,0.2402188702954857,274907.3634086092,3.4159122983871115,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK435E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,403.6,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK435E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,403.6,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL435A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,405.4,2.2048720000000004,,,72.0,11.28,48.8,10.72,40.6,0.00588816,-0.1291736,46.18,1.7821323295289642,11.284085713182504,1.4370187416705828e-11,0.24818858603407964,685.2089620092718,4.486572628156489,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM435E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,406.0,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM435E8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,406.0,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM435E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,406.0,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.6,13.57,32.1,0.005720000000000001,-0.093026,45.7,1.3299101846276373,14.309829738793544,3.5128782921162346e-12,0.16925371274894876,246.2250666615489,0.530639284403315,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435BFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435BFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435BFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435BFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435DFG,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,411.2,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005348200000000001,-0.09174625,45.0,1.323998908180012,14.310228214571435,3.016777627698544e-12,0.17577826630211554,245.75444663973389,0.7829712244460088,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435DFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,411.2,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005348200000000001,-0.09174625,45.0,1.323998908180012,14.310228214571435,3.016777627698544e-12,0.17577826630211554,245.75444663973389,0.7829712244460088,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435DFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,411.2,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005348200000000001,-0.09174625,45.0,1.323998908180012,14.310228214571435,3.016777627698544e-12,0.17577826630211554,245.75444663973389,0.7829712244460088,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435DFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,411.2,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005348200000000001,-0.09174625,45.0,1.323998908180012,14.310228214571435,3.016777627698544e-12,0.17577826630211554,245.75444663973389,0.7829712244460088,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF435DFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,435.0,411.2,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005348200000000001,-0.09174625,45.0,1.323998908180012,14.310228214571435,3.016777627698544e-12,0.17577826630211554,245.75444663973389,0.7829712244460088,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM435M7G,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,399.9,2.15,,,60.0,13.33,41.52,12.63,34.45,0.00593185,-0.12115536,46.56,1.613343299629351,13.334795363126954,8.818318798471739e-11,0.17018796504687186,473.0831939225936,8.327517289854415,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM435M7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,399.9,2.15,,,60.0,13.33,41.52,12.63,34.45,0.00593185,-0.12115536,46.56,1.613343299629351,13.334795363126954,8.818318798471739e-11,0.17018796504687186,473.0831939225936,8.327517289854415,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM435M7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,435.0,399.9,2.15,,,60.0,13.33,41.52,12.63,34.45,0.00593185,-0.12115536,46.56,1.613343299629351,13.334795363126954,8.818318798471739e-11,0.17018796504687186,473.0831939225936,8.327517289854415,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK440C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,409.1,2.19,,,144.0,11.36,49.0,10.79,40.8,0.0057481599999999996,-0.137298,45.73,1.835545722299805,11.363600735843491,2.880463272260888e-11,0.23464058188946083,740.2693984723514,4.355292070002174,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK440E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,408.4,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK440E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,408.4,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL440A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,410.2,2.2048720000000004,,,72.0,11.36,49.0,10.79,40.8,0.00592992,-0.12970299999999998,46.18,1.7906468120454178,11.364546684070904,1.4731730898878516e-11,0.24383738356960658,609.2336013054614,4.640564388186096,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM440E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,410.8,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM440E8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,410.8,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM440E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,410.8,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF440BFG,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,415.2,1.95,,,54.0,14.37,38.8,13.64,32.3,0.005748,-0.09350799999999998,45.7,1.3373004546518905,14.379507941231306,3.569302275972437e-12,0.16649830365362187,251.64024156294346,0.6216687548869104,-0.296,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF440BFG-BB,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF440BFG-BT,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF440BFG-BW,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF440BFG-WT,United Renewable Energy Co Ltd,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM440M7G,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,404.6,2.15,,,60.0,13.41,41.7,12.72,34.6,0.00596745,-0.12168060000000001,46.56,1.619448778462557,13.41381175025658,8.758330054534188e-11,0.16993776900969104,597.8528210208807,8.211066807466228,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM440M7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,404.6,2.15,,,60.0,13.41,41.7,12.72,34.6,0.00596745,-0.12168060000000001,46.56,1.619448778462557,13.41381175025658,8.758330054534188e-11,0.16993776900969104,597.8528210208807,8.211066807466228,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM440M7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,440.0,404.6,2.15,,,60.0,13.41,41.7,12.72,34.6,0.00596745,-0.12168060000000001,46.56,1.619448778462557,13.41381175025658,8.758330054534188e-11,0.16993776900969104,597.8528210208807,8.211066807466228,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK445C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,445.0,413.9,2.19,,,144.0,11.44,49.2,10.86,41.0,0.00578864,-0.13785840000000002,45.73,1.835639702713268,11.440008104073144,2.619266198324467e-11,0.2319581994411014,327443.93842825794,3.4766142069454764,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK445E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,413.2,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK445E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,413.2,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL445A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,445.0,415.0,2.2048720000000004,,,72.0,11.44,49.2,10.86,41.0,0.00597168,-0.1302324,46.18,1.7991560127923258,11.444992006744556,1.5097907470607593e-11,0.23954361297106808,548.9533773374214,4.792628652127338,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM445E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,415.6,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM445E8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,415.6,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAM445E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,415.6,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM445M7G,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,409.4,2.15,,,60.0,13.48,41.9,12.79,34.8,0.0059986,-0.1222642,46.56,1.62782945928214,13.483581439618519,8.891980851388694e-11,0.16680585810791956,627.8322044595343,8.296916037012311,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM445M7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,409.4,2.15,,,60.0,13.48,41.9,12.79,34.8,0.0059986,-0.1222642,46.56,1.62782945928214,13.483581439618519,8.891980851388694e-11,0.16680585810791956,627.8322044595343,8.296916037012311,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM445M7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,445.0,409.4,2.15,,,60.0,13.48,41.9,12.79,34.8,0.0059986,-0.1222642,46.56,1.62782945928214,13.483581439618519,8.891980851388694e-11,0.16680585810791956,627.8322044595343,8.296916037012311,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK450C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,450.0,418.6,2.19,,,144.0,11.52,49.4,10.93,41.2,0.00582912,-0.1384188,45.73,1.84335367378993,11.520008773206037,2.647262677155741e-11,0.22790756309998217,299265.75425745465,3.5073354506376067,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK450E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,450.0,418.0,2.190284,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK450E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,450.0,418.0,2.190284,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL450A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,450.0,419.8,2.2048720000000004,,,72.0,11.52,49.4,10.93,41.2,0.00601344,-0.13076179999999998,46.18,1.7969841838686,11.520009160393652,1.325783494709557e-11,0.2372942764143096,298419.95043445873,3.6040100690140706,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM450M7G,United Renewable Energy Co Ltd,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM450M7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM450M7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK455C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,455.0,423.4,2.19,,,144.0,11.6,49.6,11.0,41.4,0.005869599999999999,-0.13897920000000002,45.73,1.8618220979285522,11.604855100128345,3.099365329859322e-11,0.22192959770729734,530.2431081577184,4.806119732765015,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK455E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,455.0,422.7,2.190284,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK455E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,455.0,422.7,2.190284,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL455A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,455.0,424.6,2.2048720000000004,,,72.0,11.6,49.6,11.0,41.4,0.0060552,-0.1312912,46.18,1.8045042992712832,11.600007575524174,1.339982873294223e-11,0.23328450508339485,357218.4381162309,3.6355084633908232,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM455M7G,United Renewable Energy Co Ltd,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM455M7G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM455M7G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK460C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,460.0,428.2,2.19,,,144.0,11.67,49.8,11.06,41.6,0.0059050199999999995,-0.1395396,45.73,1.8587443695151087,11.670006538318638,2.6997709953783426e-11,0.22016074964191015,392961.5160338726,3.5635598368031367,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK460E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,460.0,427.5,2.190284,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK460E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,460.0,427.5,2.190284,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAL460A8G,United Renewable Energy Co Ltd,Mono-c-Si,1,460.0,429.4,2.2048720000000004,,,72.0,11.67,49.8,11.06,41.6,0.00609174,-0.13182059999999998,46.18,1.8119950337359891,11.670006808861357,1.3524640770911125e-11,0.22953156131228208,393406.6492862048,3.662985431955832,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK465C8G,United Renewable Energy Co Ltd,Mono-c-Si,1,465.0,433.0,2.19,,,144.0,11.75,50.0,11.13,41.8,0.0059455,-0.1401,45.73,1.866461336782094,11.75000615562789,2.7281357218389692e-11,0.21625928509074893,412805.86231370433,3.5939336907421433,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK465CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,465.0,431.7,2.39,,,78.0,11.22,52.5,10.64,43.7,0.00637296,-0.14889000000000002,46.17,1.9614425456698648,11.220009163855552,2.6647364982422522e-11,0.2570485887648649,314727.04616750905,2.45008025713691,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK465E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,465.0,432.3,2.190284,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK465E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,465.0,432.3,2.190284,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK470CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,470.0,436.4,2.39,,,78.0,11.29,52.7,10.71,43.9,0.00641272,-0.1494572,46.17,1.9800650511596065,11.294436937947335,3.096034783055079e-11,0.25084930893922586,638.2980311888712,3.675247568479154,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK470E8G,United Renewable Energy Co Ltd,Mono-c-Si,0,470.0,437.1,2.190284,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK470E8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,470.0,437.1,2.190284,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK475CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,475.0,441.2,2.39,,,78.0,11.35,52.9,10.77,44.1,0.006446800000000001,-0.15002440000000003,46.17,1.9880792540166956,11.354228330080776,3.134203989456728e-11,0.24693128304931083,662.8314425190808,3.732796158864903,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK480CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,480.0,446.0,2.39,,,78.0,11.42,53.1,10.84,44.3,0.00648656,-0.15059160000000002,46.17,1.9865867434069922,11.420008158692982,2.8137725523587622e-11,0.2446106543581712,342393.4881201623,2.755883110193001,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK485CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,485.0,450.8,2.39,,,78.0,11.48,53.3,10.9,44.5,0.006520640000000001,-0.1511588,46.17,1.9949467720192164,11.48000979753899,2.8620037304245853e-11,0.24071181197146702,282049.9908883596,2.853886654636845,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK490CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,490.0,455.5,2.39,,,78.0,11.55,53.5,10.97,44.7,0.006560400000000001,-0.15172600000000003,46.17,2.0033322294743536,11.550007336814256,2.91422552330413e-11,0.23664344129472226,372540.8503955477,2.9540195908593123,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FAK495CAG,United Renewable Energy Co Ltd,Mono-c-Si,1,495.0,460.3,2.39,,,78.0,11.62,53.7,11.03,44.9,0.00660016,-0.15229320000000002,46.17,2.0110097821481214,11.620006779080637,2.939236633625077e-11,0.23280557226998966,399056.18369367317,2.9749158107249514,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM515M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,515.0,474.8,2.54,,,72.0,13.45,49.0,12.56,41.02,0.00811035,-0.142884,46.45,1.9341314654341581,13.464992086808058,1.3051701011115164e-10,0.1627342228704174,145.99537535845786,11.667259313426717,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM515M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,515.0,474.8,2.54,,,72.0,13.45,49.0,12.56,41.02,0.00811035,-0.142884,46.45,1.9341314654341581,13.464992086808058,1.3051701011115164e-10,0.1627342228704174,145.99537535845786,11.667259313426717,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM515M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,515.0,474.8,2.54,,,72.0,13.45,49.0,12.56,41.02,0.00811035,-0.142884,46.45,1.9341314654341581,13.464992086808058,1.3051701011115164e-10,0.1627342228704174,145.99537535845786,11.667259313426717,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK520D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,520.0,481.1,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00836154,-0.14187878999999998,45.89,1.9288880860395419,13.544485906972616,1.1590532454585586e-10,0.1639491499063508,153.13035242508386,11.567846446905188,-0.3738,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK520M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,520.0,480.3,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00754974,-0.14394141000000002,45.81,1.9386099909630359,13.544182632588242,1.317219384599984e-10,0.16227088029557507,154.8037744804103,11.17136141789664,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK520M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,520.0,480.3,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00754974,-0.14394141000000002,45.81,1.9386099909630359,13.544182632588242,1.317219384599984e-10,0.16227088029557507,154.8037744804103,11.17136141789664,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBL520B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,520.0,481.1,2.54,,,72.0,13.53,49.11,12.65,41.11,0.0079827,-0.14168234999999998,46.15,1.9140322661897986,13.544956223110828,9.50875198942113e-11,0.16651986391080287,150.64055794606028,9.987930325392739,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM520M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,520.0,479.6,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00815859,-0.14320476000000001,46.45,1.9371954492790402,13.544226537884274,1.2930325934293816e-10,0.1625148706612426,154.5580702940482,11.52469663611258,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM520M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,520.0,479.6,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00815859,-0.14320476000000001,46.45,1.9371954492790402,13.544226537884274,1.2930325934293816e-10,0.1625148706612426,154.5580702940482,11.52469663611258,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM520M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,520.0,479.6,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00815859,-0.14320476000000001,46.45,1.9371954492790402,13.544226537884274,1.2930325934293816e-10,0.1625148706612426,154.5580702940482,11.52469663611258,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK525D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,525.0,485.9,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00842334,-0.14219658,45.89,1.9339361148845595,13.64466555655278,1.178424107581093e-10,0.1614384478532037,150.03904374617758,11.652200019113112,-0.3738,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK525M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,525.0,485.1,2.54,,,72.0,13.63,49.22,12.74,41.22,0.007605540000000001,-0.14426382000000001,45.81,1.9436888824561083,13.644359293782069,1.3392635133192105e-10,0.15976611496647908,151.65176101908668,11.255516140253121,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK525M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,525.0,485.1,2.54,,,72.0,13.63,49.22,12.74,41.22,0.007605540000000001,-0.14426382000000001,45.81,1.9436888824561083,13.644359293782069,1.3392635133192105e-10,0.15976611496647908,151.65176101908668,11.255516140253121,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBL525B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,525.0,485.9,2.54,,,72.0,13.63,49.22,12.74,41.22,0.0080417,-0.1419997,46.15,1.919039287883678,13.64514030899997,9.668117453276972e-11,0.16399901054206711,147.63942716334648,10.071503227365964,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM525M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,525.0,484.3,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00821889,-0.14352552000000002,46.45,1.9422687083001726,13.644403668963108,1.3146481233308083e-10,0.16000943846972848,151.4148024389307,11.609015236482218,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM525M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,525.0,484.3,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00821889,-0.14352552000000002,46.45,1.9422687083001726,13.644403668963108,1.3146481233308083e-10,0.16000943846972848,151.4148024389307,11.609015236482218,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM525M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,525.0,484.3,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00821889,-0.14352552000000002,46.45,1.9422687083001726,13.644403668963108,1.3146481233308083e-10,0.16000943846972848,151.4148024389307,11.609015236482218,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK530D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,530.0,490.7,2.54,,,72.0,13.71,49.35,12.82,41.35,0.008472780000000001,-0.14257215,45.89,1.9391660886600748,13.724306111943376,1.1877552399550218e-10,0.15907129867012226,152.4430642681811,11.66912114201594,-0.3738,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK530M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,530.0,489.8,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00765018,-0.14464485000000002,45.81,1.9489455457397764,13.724002869563483,1.349862968498977e-10,0.15740439416902527,154.11228937197748,11.27229504919357,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK530M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,530.0,489.8,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00765018,-0.14464485000000002,45.81,1.9489455457397764,13.724002869563483,1.349862968498977e-10,0.15740439416902527,154.11228937197748,11.27229504919357,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBL530B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,530.0,490.7,2.54,,,72.0,13.71,49.35,12.82,41.35,0.0080889,-0.14237475,46.15,1.9242286024338209,13.724776265950926,9.744744557601138e-11,0.16162353148938025,149.960663822285,10.088227078706831,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM530M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,530.0,489.1,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00826713,-0.14390460000000002,46.45,1.9475216222840601,13.72404679998169,1.3250558831027894e-10,0.1576469044837296,153.86700938179297,11.625905643184089,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM530M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,530.0,489.1,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00826713,-0.14390460000000002,46.45,1.9475216222840601,13.72404679998169,1.3250558831027894e-10,0.1576469044837296,153.86700938179297,11.625905643184089,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM530M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,530.0,489.1,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00826713,-0.14390460000000002,46.45,1.9475216222840601,13.72404679998169,1.3250558831027894e-10,0.1576469044837296,153.86700938179297,11.625905643184089,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK535D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,535.0,495.4,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00851604,-0.1430055,45.89,1.9445332395771733,13.79340204443129,1.1871320375780833e-10,0.15673191723336735,161.15196991213446,11.614111012101823,-0.3738,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK535M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,535.0,494.6,2.54,,,72.0,13.78,49.5,12.9,41.5,0.007689240000000001,-0.1450845,45.81,1.9543346250201377,13.793107974901401,1.3491120589783018e-10,0.1550713601730775,163.02162658382755,11.2172071149785,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK535M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,535.0,494.6,2.54,,,72.0,13.78,49.5,12.9,41.5,0.007689240000000001,-0.1450845,45.81,1.9543346250201377,13.793107974901401,1.3491120589783018e-10,0.1550713601730775,163.02162658382755,11.2172071149785,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBL535B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,535.0,495.4,2.54,,,72.0,13.78,49.5,12.9,41.5,0.0081302,-0.14280749999999998,46.15,1.9295559206245396,13.793858368249108,9.739298627674023e-11,0.15927550619996117,158.37481522640448,10.033644515568415,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM535M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,535.0,493.8,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00830934,-0.144342,46.45,1.9529090116208534,13.793150522705783,1.3243506786458322e-10,0.15531269211096033,162.7470624622273,11.570871530791399,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBM535M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,535.0,493.8,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00830934,-0.144342,46.45,1.9529090116208534,13.793150522705783,1.3243506786458322e-10,0.15531269211096033,162.7470624622273,11.570871530791399,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBM535M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,535.0,493.8,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00830934,-0.144342,46.45,1.9529090116208534,13.793150522705783,1.3243506786458322e-10,0.15531269211096033,162.7470624622273,11.570871530791399,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK540D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,540.0,500.2,2.54,,,72.0,13.85,49.65,12.97,41.65,0.0085593,-0.14343885,45.89,1.9506861733224206,13.86306562186235,1.197644965079889e-10,0.1542992852931939,163.56245135689431,11.646769192322425,-0.3738,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK540M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,540.0,499.4,2.54,,,72.0,13.85,49.65,12.97,41.65,0.007728300000000001,-0.14552415000000002,45.81,1.96051995007186,13.862774644756835,1.3610604617506036e-10,0.15264166815473734,165.49087591358216,11.249691366149868,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK540M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,540.0,499.4,2.54,,,72.0,13.85,49.65,12.97,41.65,0.007728300000000001,-0.14552415000000002,45.81,1.96051995007186,13.862774644756835,1.3610604617506036e-10,0.15264166815473734,165.49087591358216,11.249691366149868,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBL540B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,540.0,500.2,2.54,,,72.0,13.85,49.65,12.97,41.65,0.0081715,-0.14324024999999999,46.15,1.9356606710238218,13.863517202585108,9.825703650062259e-11,0.15683814849057673,160.69955127901855,10.06596011335464,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBM540M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,540.0,498.6,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008351550000000001,-0.1447794,46.45,1.9590895289328698,13.862816744795081,1.3360779824392003e-10,0.1528825890796744,165.20761984404365,11.60349442815548,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBM540M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,540.0,498.6,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008351550000000001,-0.1447794,46.45,1.9590895289328698,13.862816744795081,1.3360779824392003e-10,0.1528825890796744,165.20761984404365,11.60349442815548,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBM540M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,540.0,498.6,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008351550000000001,-0.1447794,46.45,1.9590895289328698,13.862816744795081,1.3360779824392003e-10,0.1528825890796744,165.20761984404365,11.60349442815548,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK545D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,545.0,505.0,2.54,,,72.0,13.92,49.81,13.04,41.8,0.008602559999999999,-0.14390109,45.89,1.9570223204079797,13.932788440000056,1.204922612839122e-10,0.15266901309123018,166.17763417468421,11.654707116053277,-0.3738,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK545M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,545.0,504.2,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00776736,-0.14599311000000004,45.81,1.9668879473781054,13.93249990288346,1.3693251342991578e-10,0.15101463353805597,168.17120620662365,11.25753128304291,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK545M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,545.0,504.2,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00776736,-0.14599311000000004,45.81,1.9668879473781054,13.93249990288346,1.3693251342991578e-10,0.15101463353805597,168.17120620662365,11.25753128304291,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBL545B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,545.0,505.0,2.54,,,72.0,13.92,49.81,13.04,41.8,0.0082128,-0.14370185,46.15,1.9419478654163072,13.9332363148645,9.885440526727943e-11,0.15520296542402676,163.2195465778079,10.073793776409477,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM545M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,545.0,503.4,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00839376,-0.14524596000000004,46.45,1.965453074545775,13.932541643134604,1.3441949486434862e-10,0.15125505382226526,167.8783520310379,11.611410900033826,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM545M8G-BB,United Renewable Energy Co Ltd,Mono-c-Si,0,545.0,503.4,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00839376,-0.14524596000000004,46.45,1.965453074545775,13.932541643134604,1.3441949486434862e-10,0.15125505382226526,167.8783520310379,11.611410900033826,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBM545M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,545.0,503.4,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00839376,-0.14524596000000004,46.45,1.965453074545775,13.932541643134604,1.3441949486434862e-10,0.15125505382226526,167.8783520310379,11.611410900033826,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF550B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,550.0,517.2,2.58,,,72.0,14.02,50.3,13.22,41.6,0.005047199999999999,-0.122229,45.7,1.7472807018459948,14.036991561278661,4.3363628106989216e-12,0.2422290544500371,199.8669396921313,1.6943006672687468,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF550D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,550.0,517.4,2.58,,,72.0,14.02,50.3,13.22,41.6,0.005187399999999999,-0.122229,45.6,1.7471483914874892,14.03699659646235,4.326905091087988e-12,0.2422516253571406,199.82634788924221,1.6614738766672243,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK550D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,550.0,509.7,2.54,,,72.0,13.99,49.92,13.1,42.0,0.00864582,-0.14421888,45.89,1.9644798574370392,14.002438337907186,1.2602436581548167e-10,0.14264909678247176,160.44433866500745,12.017786507093563,-0.3738,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK550M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,550.0,508.9,2.54,,,72.0,13.99,49.92,13.1,42.0,0.0078064200000000005,-0.14631552000000003,45.81,1.9744058099397623,14.002153253640884,1.432318110300975e-10,0.14098901667379626,162.2969810084504,11.619627582478941,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK550M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,550.0,508.9,2.54,,,72.0,13.99,49.92,13.1,42.0,0.0078064200000000005,-0.14631552000000003,45.81,1.9744058099397623,14.002153253640884,1.432318110300975e-10,0.14098901667379626,162.2969810084504,11.619627582478941,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBL550B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,550.0,509.8,2.54,,,72.0,13.99,49.92,13.1,42.0,0.008254099999999999,-0.14401919999999999,46.15,1.949338906178789,14.002880206502699,1.0341358114770853e-10,0.14518747475333188,157.6972233571765,10.433463859537706,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBF555B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,555.0,522.0,2.58,,,72.0,14.08,50.5,13.28,41.8,0.0050688,-0.122715,45.7,1.7547162957838878,14.09661943918679,4.3909171623414184e-12,0.23918777755668388,202.6400457915722,1.762372960771897,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF555D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,555.0,522.2,2.58,,,72.0,14.08,50.5,13.28,41.8,0.0052096,-0.122715,45.6,1.7545837056930405,14.096624412232707,4.3813635326613055e-12,0.23921030645666952,202.5985082438475,1.729588867021596,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK555D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,555.0,514.5,2.54,,,72.0,14.07,50.04,13.17,42.15,0.008695260000000002,-0.14456555999999998,45.89,1.9708148916014405,14.082416014276047,1.2933657047948278e-10,0.1378027942451593,156.16004506331282,12.203125683251224,-0.3738,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK555M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,555.0,513.7,2.54,,,72.0,14.07,50.04,13.17,42.15,0.007851060000000002,-0.14666724,45.81,1.9807848952348837,14.082130036935151,1.4700341002149897e-10,0.13614269091765296,157.91606292905007,11.804517382361267,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK555M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,555.0,513.7,2.54,,,72.0,14.07,50.04,13.17,42.15,0.007851060000000002,-0.14666724,45.81,1.9807848952348837,14.082130036935151,1.4700341002149897e-10,0.13614269091765296,157.91606292905007,11.804517382361267,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBL555B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,555.0,514.5,2.54,,,72.0,14.07,50.04,13.17,42.15,0.008301300000000001,-0.14436539999999998,46.15,1.955620570168517,14.082858851252396,1.0614247150885867e-10,0.1403388997496512,153.55713423823664,10.61708701013412,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBF560B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,560.0,526.8,2.58,,,72.0,14.13,50.7,13.34,42.0,0.0050868,-0.123201,45.7,1.7615889534751892,14.145432206101024,4.4056052493835036e-12,0.2363534295026754,216.40936750906957,1.7565974503795119,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF560D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,560.0,527.1,2.58,,,72.0,14.13,50.7,13.34,42.0,0.0052281,-0.123201,45.6,1.761456146392732,14.145437046352715,4.396040954156185e-12,0.23637590258428642,216.36208364104127,1.723868847976013,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBK560D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,560.0,519.3,2.54,,,72.0,14.16,50.14,13.26,42.24,0.00875088,-0.14485446000000002,45.89,1.9744504615108163,14.172175870410193,1.297228452119398e-10,0.13677195164609113,159.05974722611563,12.170636213974785,-0.3738,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK560M8G,United Renewable Energy Co Ltd,Mono-c-Si,0,560.0,518.5,2.54,,,72.0,14.16,50.14,13.26,42.24,0.00790128,-0.14696034000000002,45.81,1.984436253687649,14.171892053724166,1.4744046562266588e-10,0.13512050869434747,160.88948855928618,11.772041435553875,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBK560M8G-BW,United Renewable Energy Co Ltd,Mono-c-Si,0,560.0,518.5,2.54,,,72.0,14.16,50.14,13.26,42.24,0.00790128,-0.14696034000000002,45.81,1.984436253687649,14.171892053724166,1.4744046562266588e-10,0.13512050869434747,160.88948855928618,11.772041435553875,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBL560B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,560.0,519.3,2.54,,,72.0,14.16,50.14,13.26,42.24,0.0083544,-0.1446539,46.15,1.9592289575348945,14.17261560364362,1.0645739387035264e-10,0.13929534564835253,156.34781965283838,10.584866915770977,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +United Renewable Energy Co Ltd FBF565B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,565.0,531.6,2.58,,,72.0,14.19,50.9,13.41,42.1,0.0051084,-0.123687,45.7,1.7664361215301512,14.204566506856768,4.2809682590552385e-12,0.2418822331222168,235.63019511674594,1.4759790001235107,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF565D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,565.0,531.9,2.58,,,72.0,14.19,50.9,13.41,42.1,0.005250299999999999,-0.123687,45.6,1.7663024105024814,14.204571357469444,4.27162586450124e-12,0.24190470985569543,235.57364859789413,1.4431917031922028,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF570B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,570.0,536.4,2.58,,,72.0,14.25,51.1,13.48,42.3,0.00513,-0.124173,45.7,1.7732806840121902,14.263360495626365,4.296968523854561e-12,0.23889456001550766,254.79949108405276,1.4676981034794137,-0.306,N,2025.7.3,6/23/2025,4.0,bootstrapping +United Renewable Energy Co Ltd FBF570D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,570.0,536.7,2.58,,,72.0,14.25,51.1,13.48,42.3,0.0052725,-0.124173,45.6,1.7731467356330017,14.263365213430813,4.287610600649387e-12,0.23891695097346358,254.733422878211,1.4349880360254983,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF575B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,575.0,541.3,2.58,,,72.0,14.31,51.3,13.54,42.5,0.0051516,-0.124659,45.7,1.780714687577391,14.323040411465497,4.350548767651485e-12,0.2359274595204322,258.8968884431943,1.5353850459035923,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF575D8G,United Renewable Energy Co Ltd,Mono-c-Si,1,575.0,541.5,2.58,,,72.0,14.31,51.3,13.54,42.5,0.0052947,-0.124659,45.6,1.7805804793640365,14.323045064232922,4.341097689871395e-12,0.2359498241433467,258.82908172844094,1.5026941921930124,-0.305,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF580B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,580.0,546.1,2.58,,,72.0,14.37,51.4,13.6,42.7,0.005173199999999999,-0.124902,45.7,1.7863218709865352,14.382493471161162,4.521999061958346e-12,0.2255884652666696,259.4720247177978,1.8238030161289085,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF585B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,585.0,550.9,2.58,,,72.0,14.44,51.7,13.65,42.9,0.0051984,-0.125631,45.7,1.7967324326125869,14.454049476822496,4.5370834202640956e-12,0.22988293605627783,236.2728269435018,1.8159902636958567,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +United Renewable Energy Co Ltd FBF590B8G,United Renewable Energy Co Ltd,Mono-c-Si,1,590.0,555.8,2.58,,,72.0,14.49,51.8,13.69,43.1,0.0052163999999999995,-0.125874,45.7,1.8029681223568486,14.504275996464774,4.753697849214486e-12,0.21978040350250025,223.0750068668104,2.181801911562983,-0.306,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI400-108M-BB,Universal Solar Americas SA,Mono-c-Si,0,400.0,367.8,1.94,,,54.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI405-108M-BB,Universal Solar Americas SA,Mono-c-Si,0,405.0,372.6,1.94,,,54.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI445-144BMH-DG,Universal Solar Americas SA,Mono-c-Si,1,445.0,415.0,2.204872,,,72.0,11.44,49.2,10.86,41.0,0.00597168,-0.1302324,46.18,1.7991560127923258,11.444992006744556,1.5097907470607593e-11,0.23954361297106808,548.9533773374214,4.792628652127338,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI450-120M-BB,Universal Solar Americas SA,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI450-144BMH-DG,Universal Solar Americas SA,Mono-c-Si,1,450.0,419.8,2.204872,,,72.0,11.52,49.4,10.93,41.2,0.00601344,-0.13076179999999998,46.18,1.7969841838686,11.520009160393652,1.325783494709557e-11,0.2372942764143096,298419.95043445873,3.6040100690140706,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI455-120M-BB,Universal Solar Americas SA,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI540-144BMH-DG,Universal Solar Americas SA,Mono-c-Si,1,540.0,500.2,2.54,,,72.0,13.85,49.65,12.97,41.65,0.0081715,-0.14324024999999999,46.15,1.9356606710238218,13.863517202585108,9.825703650062259e-11,0.15683814849057673,160.69955127901855,10.06596011335464,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +Universal Solar Americas SA UNI545-144BMH-DG,Universal Solar Americas SA,Mono-c-Si,1,545.0,505.0,2.54,,,72.0,13.92,49.81,13.04,41.8,0.0082128,-0.14370185,46.15,1.9419478654163072,13.9332363148645,9.885440526727943e-11,0.15520296542402676,163.2195465778079,10.073793776409477,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Universal Solar Americas SA UNI550-144BMH-DG,Universal Solar Americas SA,Mono-c-Si,1,550.0,509.8,2.54,,,72.0,13.99,49.92,13.1,42.0,0.008254099999999999,-0.14401919999999999,46.15,1.949338906178789,14.002880206502699,1.0341358114770853e-10,0.14518747475333188,157.6972233571765,10.433463859537706,-0.369,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-380-54IIMJ,Venus Energy Limited,Mono-c-Si,0,380.0,356.9,1.95,,,54.0,13.41,36.05,12.65,30.04,0.0045996299999999995,-0.0917112,43.2,1.3144144046205137,13.421949279838419,1.620410372616007e-11,0.15091717019573297,169.36579357439655,8.560520057622607,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-385-54IIMJ,Venus Energy Limited,Mono-c-Si,0,385.0,361.7,1.95,,,54.0,13.53,36.19,12.77,30.16,0.00464079,-0.09206736,43.2,1.319257351830227,13.541546812603684,1.6270436450530472e-11,0.14988795986600165,175.63150158245568,8.515607487185731,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-390-54IIMJ,Venus Energy Limited,Mono-c-Si,0,390.0,366.5,1.95,,,54.0,13.65,36.34,12.88,30.28,0.00468195,-0.09244896000000002,43.2,1.324775953891361,13.661910168678771,1.6427315630984386e-11,0.14961832916341236,171.4744986969418,8.523455832599964,-0.3434,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-395-54IIMJ,Venus Energy Limited,Mono-c-Si,0,395.0,371.3,1.95,,,54.0,13.76,36.51,12.98,30.42,0.0047196799999999995,-0.09288144,43.2,1.3311224336460665,13.77229022546353,1.6605052653738356e-11,0.14924706884493136,167.09536237484681,8.548861843421571,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-400-54IIMJ,Venus Energy Limited,Mono-c-Si,0,400.0,376.1,1.95,,,54.0,13.89,36.64,13.1,30.54,0.004764269999999999,-0.09321216,43.2,1.336243777447751,13.902535000977847,1.688916636891601e-11,0.14734347313715487,163.27089686728772,8.616588178305282,-0.3434,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-405-54IIMJ,Venus Energy Limited,Mono-c-Si,0,405.0,380.9,1.95,,,54.0,14.0,36.8,13.21,30.67,0.004802,-0.0936192,43.2,1.3417033803248393,14.012200117631501,1.690234447062504e-11,0.14714115271763853,168.84887594235792,8.551722597300706,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-410-54IIMJ,Venus Energy Limited,Mono-c-Si,0,410.0,385.7,1.95,,,54.0,14.12,36.93,13.32,30.78,0.004843159999999999,-0.09394992,43.2,1.3466342685793327,14.132529380295587,1.7108776275113258e-11,0.1462508726601079,164.81759534648583,8.584621334932644,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-415-54IIMJ,Venus Energy Limited,Mono-c-Si,0,415.0,390.6,1.95,,,54.0,14.21,37.05,13.43,30.89,0.00487403,-0.09425520000000001,43.2,1.3500270013922147,14.2207543519552,1.6913976752304515e-11,0.1450416673868333,191.6472618540405,8.419284434530566,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-425-60IIMJ,Venus Energy Limited,Mono-c-Si,0,425.0,399.2,2.17,,,60.0,13.37,40.2,12.66,33.58,0.0045859099999999995,-0.1022688,43.2,1.464873184835298,13.378230472009555,1.5966440865299115e-11,0.1616058362475443,262.5207937801001,8.440071923504128,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-430-60IIMJ,Venus Energy Limited,Mono-c-Si,0,430.0,404.0,2.17,,,60.0,13.46,40.35,12.75,33.74,0.004616780000000001,-0.10265040000000002,43.2,1.470825847954186,13.467864262773837,1.6226108127154424e-11,0.15803143356584257,270.4771154818021,8.521662419822343,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-435-60IIMJ,Venus Energy Limited,Mono-c-Si,0,435.0,408.8,2.17,,,60.0,13.55,40.49,12.83,33.91,0.00464765,-0.10300656000000001,43.2,1.4773557276873142,13.558117257101062,1.6762623025698606e-11,0.15277394782257747,255.0229690431799,8.75216633729043,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-440-60IIMJ,Venus Energy Limited,Mono-c-Si,0,440.0,413.6,2.17,,,60.0,13.66,40.63,12.91,34.08,0.004685379999999999,-0.10336272000000002,43.2,1.484923964841019,13.669551561264228,1.7642426700266813e-11,0.1472488603234414,210.58540978271938,9.142152994228518,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-445-60IIMJ,Venus Energy Limited,Mono-c-Si,0,445.0,418.4,2.17,,,60.0,13.72,40.88,13.0,34.23,0.00470596,-0.10399872000000002,43.2,1.49095119803934,13.727643685757942,1.6790106732464452e-11,0.15296833164015997,274.5698422097531,8.653317730045071,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-450-60IIMJ,Venus Energy Limited,Mono-c-Si,0,450.0,423.2,2.17,,,60.0,13.8,41.13,13.09,34.38,0.0047334,-0.10463472000000001,43.2,1.4980244789010417,13.806869342088701,1.629102574108067e-11,0.15827849880993924,317.96988292720323,8.330732273250323,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-455-60IIMJ,Venus Energy Limited,Mono-c-Si,0,455.0,428.1,2.17,,,60.0,13.92,41.38,13.16,34.56,0.004774559999999999,-0.10527072000000003,43.2,1.508877876744178,13.930028772429255,1.6899138733104904e-11,0.1601688458237907,222.3153793049293,8.592329123416944,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-460-60IIMJ,Venus Energy Limited,Mono-c-Si,0,460.0,432.9,2.17,,,60.0,14.04,41.61,13.21,34.82,0.00481572,-0.10585584,43.2,1.5222224426422633,14.054082619954023,1.8529443179060027e-11,0.15346584856537562,153.00139687310346,9.353642732178765,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-510-72IIMJ,Venus Energy Limited,Mono-c-Si,0,510.0,479.1,2.58,,,72.0,13.36,48.22,12.68,40.21,0.00458248,-0.12267168,43.2,1.7537040885230069,13.366265787344323,1.5168042683081612e-11,0.20042747134672,427.3542804278994,7.984545647951838,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-515-72IIMJ,Venus Energy Limited,Mono-c-Si,0,515.0,483.9,2.58,,,72.0,13.45,48.37,12.77,40.32,0.00461335,-0.12305328,43.2,1.7585398340084506,13.455993971989827,1.512989720383451e-11,0.20108238328017053,451.2129997600587,7.901824481434026,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-520-72IIMJ,Venus Energy Limited,Mono-c-Si,0,520.0,488.7,2.58,,,72.0,13.52,48.52,12.84,40.51,0.004637359999999999,-0.12343488000000001,43.2,1.7651583930868548,13.525710405261979,1.5489934580896197e-11,0.19488655069299976,461.41492088197583,8.061792864469373,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-525-72IIMJ,Venus Energy Limited,Mono-c-Si,0,525.0,493.5,2.58,,,72.0,13.59,48.67,12.9,40.71,0.00466137,-0.12381648,43.2,1.7204262246007964,13.597476666058927,6.9681693300241555e-12,0.19689879320771475,357.89409182144243,1.2209560359423008,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-530-72IIMJ,Venus Energy Limited,Mono-c-Si,0,530.0,498.4,2.58,,,72.0,13.67,48.82,12.96,40.89,0.00468881,-0.12419808000000002,43.2,1.7803034624435445,13.677106764429887,1.6680256323024013e-11,0.18237071290371962,350.79362596372744,8.625071293599094,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-535-72IIMJ,Venus Energy Limited,Mono-c-Si,0,535.0,503.2,2.58,,,72.0,13.72,49.06,13.02,41.08,0.00470596,-0.12480864000000001,43.2,1.788000153629866,13.726323307560063,1.6491583317161108e-11,0.1836516778235474,398.4783341080901,8.4880570417902,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-540-72IIMJ,Venus Energy Limited,Mono-c-Si,0,540.0,508.0,2.58,,,72.0,13.8,49.35,13.09,41.25,0.0047334,-0.12554640000000003,43.2,1.7973897100123073,13.80687089930436,1.6285803923989024e-11,0.18999723388350465,381.60388273112187,8.327904995313476,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-545-72IIMJ,Venus Energy Limited,Mono-c-Si,0,545.0,512.8,2.58,,,72.0,13.87,49.64,13.16,41.42,0.004757409999999999,-0.12628416,43.2,1.806163969935546,13.87676092852027,1.5937262441007206e-11,0.19647001723473773,403.05694010345417,8.091516679347983,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-550-60IIMK,Venus Energy Limited,Mono-c-Si,0,550.0,515.2,2.84,,,60.0,17.3,40.06,16.47,33.39,0.0052246,-0.10291414000000002,43.1,1.475221387774014,17.30370912002256,2.773735046371603e-11,0.12700371626126938,592.3680909281254,9.998462751958709,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-550-72IIMJ,Venus Energy Limited,Mono-c-Si,0,550.0,517.6,2.58,,,72.0,13.94,49.88,13.23,41.58,0.00478142,-0.12689472000000002,43.2,1.8138011039905206,13.946588755626346,1.576048939730683e-11,0.19993225139660636,423.00181323037555,7.947932046238136,-0.3434,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-555-60IIMK,Venus Energy Limited,Mono-c-Si,0,555.0,519.9,2.84,,,60.0,17.38,40.24,16.55,33.54,0.00524876,-0.10337656000000002,43.1,1.4816872388485236,17.383453560919595,2.7790197684672136e-11,0.12699988306974166,639.1252625853373,9.97323673300713,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-560-60IIMK,Venus Energy Limited,Mono-c-Si,0,560.0,524.7,2.84,,,60.0,17.46,40.41,16.63,33.68,0.00527292,-0.10381329,43.1,1.487748804290278,17.463196322626295,2.7824983560637013e-11,0.12707942143226195,694.1748436407634,9.942392616491066,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-565-60IIMK,Venus Energy Limited,Mono-c-Si,0,565.0,529.5,2.84,,,60.0,17.54,40.58,16.7,33.82,0.00529708,-0.10425002,43.1,1.4942317134728917,17.543650229945573,2.8054536977280917e-11,0.12713096962296377,610.8867521803949,9.976572186900023,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-570-60IIMK,Venus Energy Limited,Mono-c-Si,0,570.0,534.3,2.84,,,60.0,17.61,40.76,16.78,33.97,0.00531822,-0.10471244,43.1,1.5002969080303974,17.612714235655822,2.7907035160818498e-11,0.12722439492400636,825.4337346571616,9.890450259834243,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-575-60IIMK,Venus Energy Limited,Mono-c-Si,0,575.0,539.2,2.84,,,60.0,17.69,40.93,16.86,34.11,0.005342380000000001,-0.10514917,43.1,1.506359109442794,17.692455528275023,2.794275525630941e-11,0.12730161566939882,917.1002450695737,9.86043791644309,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-580-60IIMK,Venus Energy Limited,Mono-c-Si,0,580.0,544.0,2.84,,,60.0,17.77,41.11,16.93,34.26,0.00536654,-0.10561159000000002,43.1,1.5132460646174122,17.77291189194626,2.818948740155963e-11,0.12726977623263894,776.6728726385543,9.900241862834546,-0.3587,N,2025.7.3,6/23/2025,4.0,first_pass +Venus Energy Limited VE-590-60IIMK,Venus Energy Limited,Mono-c-Si,0,590.0,553.6,2.84,,,60.0,17.93,41.45,17.08,34.55,0.00541486,-0.10648505000000001,43.1,1.526009301451416,17.93311936073866,2.8563832484896165e-11,0.12672416695916994,728.4070597437391,9.938606628327237,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-595-60IIMK,Venus Energy Limited,Mono-c-Si,0,595.0,558.4,2.84,,,60.0,18.0,41.63,17.15,34.69,0.005436,-0.10694747000000002,43.1,1.5322770512141843,18.002883012431766,2.850065352634592e-11,0.12745939722635238,795.7888746777002,9.883230896137428,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-600-60IIMK,Venus Energy Limited,Mono-c-Si,0,600.0,563.2,2.84,,,60.0,18.08,41.8,17.22,34.84,0.0054601599999999995,-0.1073842,43.1,1.538978340288009,18.08334876862101,2.8839774980730046e-11,0.12684199508691604,684.8198916439578,9.950804428446821,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-615-66IIMK,Venus Energy Limited,Mono-c-Si,0,615.0,576.3,3.12,,,66.0,17.44,44.41,16.61,37.02,0.005266880000000001,-0.11408929000000001,43.1,1.6351932596605883,17.443265832485984,2.7873579861752905e-11,0.13938962421977907,744.3600143939906,9.968448081668662,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-620-66IIMK,Venus Energy Limited,Mono-c-Si,0,620.0,581.1,3.12,,,66.0,17.51,44.59,16.68,37.16,0.00528802,-0.11455171000000001,43.1,1.6414467069282757,17.513032322539736,2.781994197759344e-11,0.1400959324446624,808.9772188677251,9.914626730576392,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-625-66IIMK,Venus Energy Limited,Mono-c-Si,0,625.0,585.9,3.12,,,66.0,17.58,44.76,16.75,37.31,0.005309159999999999,-0.11498844000000001,43.1,1.647733225722774,17.58281767402686,2.795015814845098e-11,0.13950983659849572,870.4282282567915,9.919809074399518,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-630-66IIMK,Venus Energy Limited,Mono-c-Si,0,630.0,590.7,3.12,,,66.0,17.65,44.94,16.82,37.45,0.0053303,-0.11545086,43.1,1.6539871067987753,17.652581368109967,2.7897484013541054e-11,0.14020965437351365,958.6778882328764,9.866663043346442,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-635-66IIMK,Venus Energy Limited,Mono-c-Si,0,635.0,595.5,3.12,,,66.0,17.72,45.11,16.89,37.6,0.00535144,-0.11588759000000001,43.1,1.6602738237591181,17.722368545916286,2.802766660360586e-11,0.13962789965234987,1044.6098244593868,9.872012654429398,-0.3587,N,2025.7.3,6/23/2025,2.0,first_pass +Venus Energy Limited VE-640-66IIMK,Venus Energy Limited,Mono-c-Si,0,640.0,600.3,3.12,,,66.0,17.79,45.28,16.69,37.74,0.00537258,-0.11632432000000002,43.1,1.679208592317338,17.8112404323983,3.3908339884338056e-11,0.1388277040343415,116.27563986921174,11.61758283291843,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-645-66IIMK,Venus Energy Limited,Mono-c-Si,0,645.0,605.1,3.12,,,66.0,17.87,45.46,17.03,37.89,0.0053967400000000006,-0.11678674000000001,43.1,1.6732551228212496,17.872597625789183,2.8304983126271727e-11,0.13963802236919534,960.6201033918978,9.885405433708943,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-650-66IIMK,Venus Energy Limited,Mono-c-Si,0,650.0,609.9,3.12,,,66.0,17.94,45.63,17.09,38.03,0.00541788,-0.11722347000000002,43.1,1.6797855396722938,17.943083030846992,2.852870612948404e-11,0.13970727565385532,812.9495712325721,9.922529321670902,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-655-66IIMK,Venus Energy Limited,Mono-c-Si,0,655.0,614.7,3.12,,,66.0,18.01,45.81,17.16,38.18,0.00543902,-0.11768589000000002,43.1,1.6862581009139443,18.01285904969239,2.8575612118892576e-11,0.1397241774177877,880.1639654738814,9.901567721847474,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Venus Energy Limited VE-660-66IIMK,Venus Energy Limited,Mono-c-Si,0,660.0,619.5,3.12,,,66.0,18.08,45.98,17.22,38.32,0.0054601599999999995,-0.11812262,43.1,1.6927886471212594,18.083345014098082,2.879959048024815e-11,0.13979258003208453,755.5872266131926,9.938362418661258,-0.3587,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN295-60MM5BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,295.0,271.6,1.63,,,60.0,9.47,39.0,9.23,32.0,0.005775658300000001,-0.11715600000000001,44.8,1.5661131112861917,9.470094221180217,1.4495687998278998e-10,0.13314739742198084,13382.409956782121,12.33907760974791,-0.40045,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN300-60M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN300-60M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN300-60M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,300.0,278.3,1.607856,,,60.0,9.74,39.8,9.21,32.6,0.00366224,-0.10797739999999999,45.3,1.4755607964518032,9.7469344346838,1.8636692624238234e-11,0.2908450651737146,408.51646603314555,5.5573018834057235,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN300-60MM5BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,300.0,276.4,1.63,,,60.0,9.63,39.7,9.33,32.2,0.005873240700000001,-0.11925880000000001,44.8,1.581443588711432,9.630191614922742,1.2052959460638027e-10,0.2142510921683936,10767.645071369176,10.528358784470106,-0.40045,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN305-60M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN305-60M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN305-60M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,305.0,283.0,1.607856,,,60.0,9.83,40.0,9.3,32.8,0.00369608,-0.10852,45.3,1.4834384414410016,9.836511070567164,1.8977422135173135e-11,0.2851511833644924,430.5031174283037,5.6316621436374925,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN305-60MM5BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,305.0,281.1,1.63,,,60.0,9.75,39.8,9.43,32.4,0.0059464275,-0.11955919999999999,44.8,1.5867640922456068,9.75018244530035,1.246421615892023e-10,0.20833367068032788,11133.511540184314,10.717359766109508,-0.40045,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN310-60M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN310-60M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN310-60M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,310.0,287.8,1.607856,,,60.0,9.92,40.2,9.4,33.0,0.00372992,-0.1090626,45.3,1.490565698094921,9.925188595416074,1.9084273658329173e-11,0.27959171085116147,534.5473301750314,5.595318450717908,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN310-60MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,310.0,286.7,1.6626506,,,60.0,9.92,40.2,9.4,33.0,0.00393824,-0.10689180000000002,45.5,1.5083187821285657,9.924687607617333,2.6229466163808863e-11,0.275481085827521,582.9780717185328,10.527167469039822,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN310-60MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,310.0,286.7,1.6626506,,,60.0,9.92,40.2,9.4,33.0,0.00393824,-0.10689180000000002,45.5,1.5083187821285657,9.924687607617333,2.6229466163808863e-11,0.275481085827521,582.9780717185328,10.527167469039822,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN310-60MM5BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,310.0,285.9,1.63,,,60.0,9.83,40.1,9.52,32.6,0.0059952187,-0.12046040000000001,44.8,1.5987436794275875,9.83018322684545,1.257020687937142e-10,0.2057811979838568,11040.045297242576,10.720016774370604,-0.40045,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,291.1,1.681248,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,291.1,1.681248,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,291.1,1.681248,,,60.0,10.08,39.9,9.52,33.1,0.004183200000000001,-0.1076502,47.1,1.472652934468996,10.087954228788197,1.703101222324427e-11,0.23505601081053804,297.87477592698485,5.04436471678749,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-60M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-60M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-60M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,292.5,1.607856,,,60.0,10.01,40.4,9.49,33.2,0.00376376,-0.10960519999999999,45.3,1.4984496942983228,10.01480494517888,1.9429600462447997e-11,0.27411731568092723,571.0604984497046,5.669642406707229,-0.361,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-60MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,291.5,1.6626506,,,60.0,10.01,40.4,9.49,33.2,0.003973969999999999,-0.10742360000000001,45.5,1.5162980210567456,10.014312294120787,2.670205506788251e-11,0.27002094831551277,626.7916071715464,10.604202267207045,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-60MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,291.5,1.6626506,,,60.0,10.01,40.4,9.49,33.2,0.003973969999999999,-0.10742360000000001,45.5,1.5162980210567456,10.014312294120787,2.670205506788251e-11,0.27002094831551277,626.7916071715464,10.604202267207045,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN315-60MM5BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,315.0,290.6,1.63,,,60.0,9.92,40.2,9.62,32.8,0.0060501088,-0.1207608,44.8,1.60630359952271,9.920138097557684,1.341392740501676e-10,0.1837252039324825,13197.443107617188,11.220190915054904,-0.40045,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,295.8,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,295.8,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,295.8,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.00422055,-0.1084596,47.1,1.482252219754461,10.17774813395648,1.6739131044662465e-11,0.2406111742616705,315.81998017853977,4.818942775082891,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,297.1,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.0035798400000000004,-0.1073742,46.0,1.470586869614562,10.17808480595428,1.3493971541644573e-11,0.24329426452417346,306.043546658805,4.137005085250907,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,297.1,1.681248,,,60.0,10.17,40.2,9.61,33.3,0.0035798400000000004,-0.1073742,46.0,1.470586869614562,10.17808480595428,1.3493971541644573e-11,0.24329426452417346,306.043546658805,4.137005085250907,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-60M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,294.5,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-60M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,294.5,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-60M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,294.5,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00413908,-0.11002600000000001,47.0,1.5275355064052731,10.124664476300667,2.879485629806404e-11,0.2635183867220535,571.7268091006089,9.064485830346651,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-60MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,296.2,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00401764,-0.10795540000000002,45.5,1.5249576510772322,10.124734683161039,2.752744209195485e-11,0.2641028903557208,564.4984535624722,10.78115587885921,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN320-60MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,320.0,296.2,1.6626506,,,60.0,10.12,40.6,9.59,33.4,0.00401764,-0.10795540000000002,45.5,1.5249576510772322,10.124734683161039,2.752744209195485e-11,0.2641028903557208,564.4984535624722,10.78115587885921,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,300.6,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,300.6,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,300.6,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0042662,-0.10899919999999999,47.1,1.49069148582734,10.288062440841005,1.7241236966924295e-11,0.23513021378314947,299.8023333310494,4.980901540396099,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,301.9,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0036185600000000003,-0.10790839999999999,46.0,1.4789509114164092,10.288402165735683,1.3898622943443762e-11,0.23780505783233014,290.9530814429537,4.297942002643689,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,301.9,1.681248,,,60.0,10.28,40.4,9.71,33.5,0.0036185600000000003,-0.10790839999999999,46.0,1.4789509114164092,10.288402165735683,1.3898622943443762e-11,0.23780505783233014,290.9530814429537,4.297942002643689,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-60M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-60M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-60M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,299.2,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00418816,-0.11029700000000002,47.0,1.53586818918898,10.246623875050355,3.143240456874383e-11,0.24692055113790373,381.72013732636526,9.746960648711614,-0.3702,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-60MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN325-60MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,325.0,301.0,1.6626506,,,60.0,10.24,40.7,9.68,33.6,0.00406528,-0.10822130000000002,45.5,1.5332533084816453,10.246696687122231,3.004098145591822e-11,0.24750979942126483,378.4707792897311,11.47212449888557,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,305.4,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,305.4,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,305.4,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.00429525,-0.1095388,47.1,1.4970888665903588,10.356206001849536,1.7099911302197068e-11,0.230845491494929,384.99035623753156,4.843054806691595,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,306.6,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.0036432,-0.10844260000000001,46.0,1.4853031656544802,10.356523293773137,1.3784062863815299e-11,0.23350649383129052,370.486492842027,4.16027778531454,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,306.6,1.681248,,,60.0,10.35,40.6,9.8,33.7,0.0036432,-0.10844260000000001,46.0,1.4853031656544802,10.356523293773137,1.3784062863815299e-11,0.23350649383129052,370.486492842027,4.16027778531454,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-60MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN330-60MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,330.0,305.7,1.6626506,,,60.0,10.34,40.9,9.77,33.8,0.00410498,-0.1087531,45.5,1.5419474484208828,10.347074587842693,3.092595071137229e-11,0.24217177320797484,353.9508215822409,11.648648221277833,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,310.1,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,310.1,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,310.1,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0043243000000000005,-0.11007839999999999,47.1,1.5035014115803094,10.424412838547637,1.696539051460718e-11,0.22663328672274166,535.1473562300899,4.70868830430005,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,311.4,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0036678400000000003,-0.1089768,46.0,1.4916704712639977,10.424707889486557,1.3675037155016914e-11,0.22928073147299358,507.46842156262517,4.026101173018075,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,311.4,1.681248,,,60.0,10.42,40.8,9.89,33.9,0.0036678400000000003,-0.1089768,46.0,1.4916704712639977,10.424707889486557,1.3675037155016914e-11,0.22928073147299358,507.46842156262517,4.026101173018075,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-60MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,310.5,1.6626506,,,60.0,10.41,41.2,9.86,34.0,0.00413277,-0.10955080000000002,45.5,1.550330407922102,10.415238841369867,2.970316332019816e-11,0.24806821503615692,492.93154694445747,11.213345460746005,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN335-60MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,335.0,310.5,1.6626506,,,60.0,10.41,41.2,9.86,34.0,0.00413277,-0.10955080000000002,45.5,1.550330407922102,10.415238841369867,2.970316332019816e-11,0.24806821503615692,492.93154694445747,11.213345460746005,-0.3705,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN340-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,340.0,314.9,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN340-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,340.0,314.9,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN340-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,340.0,314.9,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0043658,-0.11061800000000001,47.1,1.5119823138362651,10.52479688214548,1.7461342069935868e-11,0.22165250077115128,486.10415441829366,4.874758414420471,-0.3476,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN340-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,340.0,316.2,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0037030400000000003,-0.10951100000000001,46.0,1.5000754629857609,10.525095002328262,1.4074691801651124e-11,0.22429505419933127,463.11735364585354,4.1911968749579716,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN340-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,340.0,316.2,1.681248,,,60.0,10.52,41.0,9.98,34.1,0.0037030400000000003,-0.10951100000000001,46.0,1.5000754629857609,10.525095002328262,1.4074691801651124e-11,0.22429505419933127,463.11735364585354,4.1911968749579716,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN345-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,345.0,321.0,1.681248,,,60.0,10.69,41.2,10.06,34.3,0.00376288,-0.11004520000000001,46.0,1.5139648725580341,10.701083665498308,1.595095835029606e-11,0.21738028389039898,209.65945312218443,5.152786144849423,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN345-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,345.0,321.0,1.681248,,,60.0,10.69,41.2,10.06,34.3,0.00376288,-0.11004520000000001,46.0,1.5139648725580341,10.701083665498308,1.595095835029606e-11,0.21738028389039898,209.65945312218443,5.152786144849423,-0.3469,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN350-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN350-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN350-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,350.0,324.4,1.83,,,60.0,10.78,41.4,10.15,34.5,0.00606914,-0.1195218,45.16,1.6025894997923786,10.788336093935275,6.413464921121512e-11,0.19529806847100348,252.55392255568088,8.446068239210659,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN355-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN355-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN355-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,355.0,329.1,1.83,,,60.0,11.26,40.3,10.51,33.8,0.00633938,-0.1163461,45.16,1.5723982722754195,11.272996399951978,8.122071963054908e-11,0.1570646679420197,136.0798503753032,10.184509009720546,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,333.9,1.83,,,60.0,11.35,40.5,10.59,34.0,0.00639005,-0.11692350000000001,45.16,1.5813197012993643,11.363054172743144,8.332191012894033e-11,0.153005451899819,133.031172130782,10.342954582138296,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,333.6,1.829752,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,333.6,1.829752,,,60.0,11.35,40.5,10.59,34.0,0.00532315,-0.11360250000000002,45.79,1.5519758488291262,11.364044704867108,5.1295451574165273e-11,0.15911852024716316,128.58904736082314,9.35543228939313,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,360.0,335.8,1.99,,,72.0,9.68,47.7,9.18,39.2,0.0031556799999999997,-0.1269297,43.8,1.75337668571824,9.684748836244431,1.472806128667323e-11,0.3382822754920748,689.5526216940445,5.709477017996668,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN360-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,360.0,334.8,1.9188,,,72.0,9.67,47.7,9.19,39.2,0.0037809700000000007,-0.12879000000000002,44.5,1.773686692736379,9.672501992447021,2.0152668413030003e-11,0.3334425346491255,1288.7286851799242,6.762211487424515,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,365.0,340.7,1.83,,,60.0,11.19,41.1,10.66,34.3,0.00349128,-0.11031240000000002,45.32,1.4825121309335765,11.192655571528878,1.0163192291480109e-11,0.20342421016254392,857.185324360902,0.5145881496169558,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,338.6,1.83,,,60.0,11.43,40.7,10.68,34.2,0.00643509,-0.11750090000000002,45.16,1.588736343452087,11.44206580210077,8.351484961050974e-11,0.14943153681679497,141.55731000911823,10.295505513488294,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,338.3,1.829752,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,338.3,1.829752,,,60.0,11.43,40.7,10.68,34.2,0.00536067,-0.11416350000000001,45.79,1.5592587388750965,11.443019958593807,5.141131669272125e-11,0.15552281058099954,136.53082896251118,9.307653251537161,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,365.0,340.6,1.99,,,72.0,9.72,47.9,9.25,39.5,0.00316872,-0.1274619,43.8,1.7608969221362214,9.72200059615587,1.488281251405169e-11,0.32152217580050313,1562.1321938137003,5.749352111334836,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN365-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,365.0,339.6,1.9188,,,72.0,9.75,47.9,9.27,39.4,0.0038122500000000005,-0.12933,44.5,1.7815798081929684,9.75220168106239,2.0468225048296822e-11,0.32767706990386464,1451.0964527901544,6.823716074441961,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,370.0,345.5,1.83,,,60.0,11.26,41.4,10.72,34.5,0.0035131200000000002,-0.11111760000000001,45.32,1.4926967531021205,11.263145563061638,1.0100590684614451e-11,0.2089687860073676,748.0337697733061,0.4154669057332421,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,343.4,1.83,,,60.0,11.52,40.9,10.76,34.4,0.00648576,-0.1180783,45.16,1.597656273026559,11.532122260405337,8.564171402401986e-11,0.14549444569760744,138.26596525485556,10.45165491729502,-0.3706,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,343.1,1.829752,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,343.1,1.829752,,,60.0,11.52,40.9,10.76,34.4,0.00540288,-0.11472450000000001,45.79,1.5679967690638155,11.533083771422213,5.272411496880026e-11,0.15158231147506374,133.46520557674975,9.463013691523843,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,370.0,345.3,1.99,,,72.0,9.79,48.2,9.32,39.7,0.0031915399999999992,-0.12826020000000002,43.8,1.7673290987083512,9.790007185335138,1.4007314567221396e-11,0.3277728308729297,446594.0889380231,5.159063741778002,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,344.4,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.0038435300000000004,-0.12987,44.5,1.7894747909365618,9.831909665656747,2.0786490982349465e-11,0.32201001155657266,1657.5459574608544,6.8849314526705605,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,342.6,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.00329305,-0.1300143,45.8,1.7825835461248614,9.832051811597243,1.8731392619518233e-11,0.32361889961090945,1550.4220312363548,5.944855852464915,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN370-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,370.0,342.6,1.9188,,,72.0,9.83,48.1,9.35,39.6,0.00329305,-0.1300143,45.8,1.7825835461248614,9.832051811597243,1.8731392619518233e-11,0.32361889961090945,1550.4220312363548,5.944855852464915,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,375.0,350.3,1.83,,,60.0,11.32,41.6,10.78,34.8,0.00353184,-0.11165440000000001,45.32,1.50255649164443,11.322966875362306,1.0662684285075631e-11,0.19473513588085828,743.0045064023695,0.8149591490204783,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,347.9,1.829752,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,347.9,1.829752,,,60.0,11.6,41.1,10.84,34.6,0.005440399999999999,-0.11528550000000003,45.79,1.5760334469491608,11.612632749850519,5.344178797830697e-11,0.14796187357659482,135.86572742360227,9.519637284442771,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,346.7,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0036900000000000006,-0.123324,44.4,1.8442809865817016,10.004209210874183,5.5071174622891826e-11,0.2712848568630468,644.5029191867094,20.913771959564944,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,346.9,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0035200000000000006,-0.123802,44.3,1.8403704061538573,10.00428728261265,5.2114750949449136e-11,0.27218043799176433,634.855393948642,19.93169112516487,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,346.9,1.99,,,72.0,10.0,47.8,9.47,39.6,0.0035200000000000006,-0.123802,44.3,1.8403704061538573,10.00428728261265,5.2114750949449136e-11,0.27218043799176433,634.855393948642,19.93169112516487,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,375.0,350.1,1.99,,,72.0,9.85,48.5,9.4,39.9,0.0032110999999999997,-0.1290585,43.8,1.779304242638775,9.850004448586068,1.430545482799251e-11,0.33278271921562674,736855.5929858502,5.286446666037689,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,349.2,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.00387872,-0.13041,44.5,1.7982286578006934,9.92243955983724,2.1375809160117156e-11,0.3160724145015024,1285.247622780456,7.0509162845968705,-0.3631,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,347.3,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.0033232,-0.1305549,45.8,1.7912998165493903,9.922583580821144,1.926279178157259e-11,0.31767762796775906,1219.7648499848483,6.109514590274358,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN375-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,375.0,347.3,1.9188,,,72.0,9.92,48.3,9.43,39.8,0.0033232,-0.1305549,45.8,1.7912998165493903,9.922583580821144,1.926279178157259e-11,0.31767762796775906,1219.7648499848483,6.109514590274358,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,380.0,355.1,1.83,,,60.0,11.4,41.8,10.86,35.0,0.0035568,-0.1121912,45.32,1.5102257662692662,11.402730747941662,1.0829590096307663e-11,0.19088309866610503,796.8759471926134,0.8832772989449614,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,352.7,1.829752,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,352.7,1.829752,,,60.0,11.69,41.3,10.92,34.8,0.00548261,-0.1158465,45.79,1.584770386923841,11.702681401802952,5.4781975449143686e-11,0.1441354419179769,132.8672772930865,9.672321461956756,-0.3634,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,380.0,351.8,2.02,,,72.0,9.94,48.7,9.47,40.2,0.00365792,-0.12686350000000002,44.1,1.8703538668471484,9.94000293109458,4.8897683363662693e-11,0.2948571030371771,999999.7951051213,18.63565893658903,-0.3943,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,351.4,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0037121400000000005,-0.12409800000000001,44.4,1.856785804107578,10.063978102210285,5.614006859183605e-11,0.26515197448458017,670.5280136961721,21.04166220780335,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035411200000000005,-0.12457900000000001,44.3,1.8528489333641933,10.06405444318326,5.3127904276577706e-11,0.266048689514278,660.127620280329,20.058810123472938,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,351.7,1.99,,,72.0,10.06,48.1,9.53,39.9,0.0035411200000000005,-0.12457900000000001,44.3,1.8528489333641933,10.06405444318326,5.3127904276577706e-11,0.266048689514278,660.127620280329,20.058810123472938,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,380.0,354.9,1.99,,,72.0,9.94,48.8,9.46,40.2,0.00324044,-0.1298568,43.8,1.7892102038277642,9.94000714996007,1.4196194125987256e-11,0.3262342364345687,453539.2695784441,5.143638452280042,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,349.5,1.968096,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,349.5,1.968096,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,349.5,1.968096,,,72.0,10.01,48.5,9.51,40.0,0.00402402,-0.1299315,47.8,1.8015918196747234,10.013066480640118,2.0277247322028114e-11,0.311474536359776,1016.7552217365081,7.345859477560699,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,352.1,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.00335335,-0.13109549999999998,45.8,1.8000140046246078,10.013099647262754,1.9803509057510975e-11,0.31183748503709674,1007.0479063479752,6.272566077752904,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN380-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,380.0,352.1,1.9188,,,72.0,10.01,48.5,9.51,40.0,0.00335335,-0.13109549999999998,45.8,1.8000140046246078,10.013099647262754,1.9803509057510975e-11,0.31183748503709674,1007.0479063479752,6.272566077752904,-0.3646,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,385.0,359.9,1.83,,,60.0,11.47,42.0,10.94,35.2,0.00357864,-0.11272800000000001,45.32,1.5172741536443375,11.471873718624392,1.0875377592628634e-11,0.18732269081304131,1146.6990156981208,0.8625772931840445,-0.3387,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,385.0,356.5,2.02,,,72.0,10.02,48.9,9.54,40.4,0.0036873599999999998,-0.1273845,44.1,1.8788252475668925,10.020272683365336,4.981287156802317e-11,0.2911013858907928,10696.794310584786,18.73804008578913,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.2,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00373428,-0.124872,44.4,1.8692887219444911,10.123754524450764,5.721609019111164e-11,0.25909762756615407,698.3755593332944,21.16771564160557,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00356224,-0.125356,44.3,1.865325586339818,10.123829146069554,5.4147856091863336e-11,0.2599954544828044,687.1386003150868,20.184106080070023,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.4,1.99,,,72.0,10.12,48.4,9.59,40.2,0.00356224,-0.125356,44.3,1.865325586339818,10.123829146069554,5.4147856091863336e-11,0.2599954544828044,687.1386003150868,20.184106080070023,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,385.0,359.7,1.99,,,72.0,10.03,49.0,9.53,40.4,0.00326978,-0.130389,43.8,1.80250495986218,10.033347138476286,1.560249218969472e-11,0.3195321732586691,957.5066370870326,5.891980686967847,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,354.2,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.00405618,-0.13046730000000004,47.8,1.810356050273638,10.093605108439432,2.0831966073017292e-11,0.3060341896239549,856.5304190506392,7.5143995755416455,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.0,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN385-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,385.0,356.0,1.968096,,,72.0,10.09,48.7,9.58,40.2,0.0046313100000000005,-0.1311004,46.6,1.81886404178102,10.093426114481803,2.3630774095586194e-11,0.3040918887014247,895.5588780342166,8.01314084366093,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,390.0,365.6,1.95,,,108.0,13.5,36.84,12.66,30.82,0.0068985,-0.09460512,44.9,1.3470273279876641,13.516513779716616,1.7498480684569672e-11,0.14230086464529892,116.33083781843973,7.954534729809155,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,358.3,1.94,,,108.0,13.5,36.84,12.66,30.82,0.008518500000000002,-0.11479344000000001,45.83,1.4998219104067805,13.510332428734404,2.85251917761413e-10,0.11579955583629135,151.299769221344,11.155789370189236,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,358.3,1.94,,,54.0,13.5,36.84,12.66,30.82,0.008518500000000002,-0.11479344000000001,45.83,1.4998219104067805,13.510332428734404,2.85251917761413e-10,0.11579955583629135,151.299769221344,11.155789370189236,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,358.3,1.94,,,54.0,13.5,36.84,12.66,30.82,0.008518500000000002,-0.11479344000000001,45.83,1.4998219104067805,13.510332428734404,2.85251917761413e-10,0.11579955583629135,151.299769221344,11.155789370189236,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,365.1,1.95,,,54.0,13.5,36.84,12.66,30.82,0.0063315,-0.09571032,45.47,1.336963089542949,13.516976714011111,1.4237885273202925e-11,0.14408495185647766,114.57734718816022,4.98178950099881,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,365.1,1.95,,,54.0,13.5,36.84,12.66,30.82,0.0063315,-0.09571032,45.47,1.336963089542949,13.516976714011111,1.4237885273202925e-11,0.14408495185647766,114.57734718816022,4.98178950099881,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,365.1,1.95,,,54.0,13.5,36.84,12.66,30.82,0.0063315,-0.09571032,45.47,1.336963089542949,13.516976714011111,1.4237885273202925e-11,0.14408495185647766,114.57734718816022,4.98178950099881,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,390.0,361.3,2.02,,,72.0,10.11,49.1,9.61,40.6,0.00372048,-0.1279055,44.1,1.8888196044867658,10.111535791483307,5.178179646456235e-11,0.2853672560425699,1878.5514444670425,19.03188159064435,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,361.0,1.99,,,72.0,10.22,48.5,9.68,40.3,0.0037711800000000007,-0.12513,44.4,1.8740068147617066,10.22411778237311,5.843247876920904e-11,0.2550099993661389,632.9140461870792,21.27968098345184,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.003597440000000001,-0.125615,44.3,1.8593275438544012,10.220004579511636,4.7974062814489926e-11,0.2581122665961081,576042.6087871741,18.89679258881582,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,361.2,1.99,,,72.0,10.22,48.5,9.68,40.3,0.003597440000000001,-0.125615,44.3,1.8593275438544012,10.220004579511636,4.7974062814489926e-11,0.2581122665961081,576042.6087871741,18.89679258881582,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-72BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,390.0,364.5,1.99,,,72.0,10.11,49.3,9.61,40.6,0.0032958599999999994,-0.1311873,43.8,1.8121311060635106,10.113005149072462,1.5407163303438524e-11,0.3246264701179815,1092.1163467986844,5.713718096467374,-0.3584,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,359.0,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.00409236,-0.1310031,47.8,1.8190733648147401,10.18408932758851,2.140420371724229e-11,0.3003813994581279,747.7715223956264,7.675842797219153,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,360.7,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN390-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,390.0,360.7,1.968096,,,72.0,10.18,48.9,9.66,40.4,0.004672620000000001,-0.1316388,46.6,1.8276275748354198,10.18390804857601,2.4279590901940797e-11,0.29844323483391344,777.4090192416587,8.175228903203175,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,395.0,370.2,1.95,,,54.0,13.59,37.03,12.75,31.0,0.00587088,-0.09505601,45.36,1.3346682501124179,13.60695590718355,1.1857504927065774e-11,0.14366015652333317,115.14226336720056,4.680878978772934,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,395.0,370.4,1.95,,,108.0,13.59,37.03,12.75,31.0,0.006944489999999999,-0.09509303999999999,44.9,1.354148545340648,13.606067542949754,1.768516130390092e-11,0.14022549878329235,118.60335676304534,7.987748532936394,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,363.1,1.94,,,108.0,13.59,37.03,12.75,31.0,0.00857529,-0.11538548,45.83,1.4614591949708724,13.601638152577111,1.321801955202104e-10,0.12162535369676632,142.0232794840813,4.4090406881824205,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,363.1,1.94,,,54.0,13.59,37.03,12.75,31.0,0.00857529,-0.11538548,45.83,1.4614591949708724,13.601638152577111,1.321801955202104e-10,0.12162535369676632,142.0232794840813,4.4090406881824205,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,363.1,1.94,,,54.0,13.59,37.03,12.75,31.0,0.00857529,-0.11538548,45.83,1.4614591949708724,13.601638152577111,1.321801955202104e-10,0.12162535369676632,142.0232794840813,4.4090406881824205,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,369.9,1.95,,,54.0,13.59,37.03,12.75,31.0,0.0063737099999999994,-0.09620394,45.47,1.3440308161925618,13.606525642499864,1.4390077535049174e-11,0.14200709991372115,116.78072384940928,5.014264805883574,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,369.9,1.95,,,54.0,13.59,37.03,12.75,31.0,0.0063737099999999994,-0.09620394,45.47,1.3440308161925618,13.606525642499864,1.4390077535049174e-11,0.14200709991372115,116.78072384940928,5.014264805883574,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,369.9,1.95,,,54.0,13.59,37.03,12.75,31.0,0.0063737099999999994,-0.09620394,45.47,1.3440308161925618,13.606525642499864,1.4390077535049174e-11,0.14200709991372115,116.78072384940928,5.014264805883574,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,395.0,366.1,2.02,,,72.0,10.19,49.3,9.69,40.8,0.0037499199999999995,-0.1284265,44.1,1.8969643961230733,10.191278177798583,5.2535802677672267e-11,0.28018836136610215,2233.7422988053127,19.093278838242796,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.7,1.99,,,72.0,10.31,48.7,9.76,40.5,0.003804390000000001,-0.125646,44.4,1.8830395844188492,10.314493469561098,5.997074279685646e-11,0.2497553505217265,573.0488944324228,21.45092379307949,-0.3948,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.9,1.99,,,72.0,10.31,48.7,9.76,40.5,0.0036291200000000004,-0.12613300000000002,44.3,1.8790482451806139,10.31457040693587,5.675915372478459e-11,0.2506448420395685,565.4088229842696,20.4657332840842,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-72M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-72M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-72M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,363.7,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.00412854,-0.13153890000000001,47.8,1.8277886007338462,10.274558423863313,2.1986058669354845e-11,0.29482257413688867,664.2269321831556,7.835725329715399,-0.3598,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.5,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN395-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,395.0,365.5,1.968096,,,72.0,10.27,49.1,9.74,40.6,0.004713930000000001,-0.13217720000000002,46.6,1.8363889223386227,10.274374861334504,2.4939269265607463e-11,0.29288850192564625,687.5566458312517,8.33573936338623,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,400.0,375.0,1.95,,,54.0,13.68,37.2,12.84,31.17,0.005909760000000001,-0.0954924,45.36,1.3411090804094017,13.696449960223058,1.2018833567900458e-11,0.14093129725561596,117.20029257592347,4.73832653389208,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,400.0,375.2,1.95,,,108.0,13.68,37.2,12.84,31.17,0.00699048,-0.0955296,44.9,1.3606865495906277,13.695572777925639,1.7925243402156867e-11,0.13750184160041437,120.78931482737923,8.046722764351191,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,367.8,1.94,,,108.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,367.8,1.94,,,54.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,367.8,1.94,,,54.0,13.68,37.2,12.84,31.17,0.00863208,-0.11591520000000001,45.83,1.5150893632174687,13.689558205742031,2.9219043424880024e-10,0.11107237087312771,158.97022495055606,11.249901491206902,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,374.7,1.95,,,54.0,13.68,37.2,12.84,31.17,0.0064159199999999994,-0.0966456,45.47,1.3505195798386562,13.696025003463731,1.4586022090617975e-11,0.13928053066502066,118.89904847633342,5.071968471467868,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,374.7,1.95,,,54.0,13.68,37.2,12.84,31.17,0.0064159199999999994,-0.0966456,45.47,1.3505195798386562,13.696025003463731,1.4586022090617975e-11,0.13928053066502066,118.89904847633342,5.071968471467868,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,374.7,1.95,,,54.0,13.68,37.2,12.84,31.17,0.0064159199999999994,-0.0966456,45.47,1.3505195798386562,13.696025003463731,1.4586022090617975e-11,0.13928053066502066,118.89904847633342,5.071968471467868,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,400.0,371.8,2.02,,,66.0,11.35,44.9,10.82,37.0,0.0032688,-0.12100550000000002,45.71,1.6295656111888066,11.351148468196323,1.224934311469785e-11,0.264811858296979,2617.0639533325516,1.5367033704439454,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,400.0,370.8,2.02,,,72.0,10.27,49.5,9.76,41.0,0.00377936,-0.1289475,44.1,1.9060547876410128,10.271775061398586,5.392072254432332e-11,0.2749902088040534,1591.0152241884116,19.271336823762127,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036572800000000006,-0.126651,44.3,1.888111286326416,10.39496441517563,5.822153708655742e-11,0.24570320177805335,514.2310217656832,20.640799378756142,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,370.7,1.99,,,72.0,10.39,48.9,9.83,40.7,0.0036572800000000006,-0.126651,44.3,1.888111286326416,10.39496441517563,5.822153708655742e-11,0.24570320177805335,514.2310217656832,20.640799378756142,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,370.2,1.968096,,,72.0,10.35,49.3,9.81,40.8,0.00475065,-0.1327156,46.6,1.8451951318838913,10.354863231731121,2.560095628839045e-11,0.28769900702457224,612.2851941076362,8.500356580606194,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN400-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,400.0,370.2,1.968096,,,72.0,10.35,49.3,9.81,40.8,0.00475065,-0.1327156,46.6,1.8451951318838913,10.354863231731121,2.560095628839045e-11,0.28769900702457224,612.2851941076362,8.500356580606194,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,379.8,1.95,,,54.0,13.78,37.36,12.92,31.36,0.00595296,-0.09590312,45.36,1.3487699621136995,13.796953394400314,1.2569332237580273e-11,0.1354811729166399,110.12134348662845,5.0643208184107165,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,380.0,1.95,,,108.0,13.78,37.36,12.92,31.36,0.00704158,-0.09594047999999998,44.9,1.3684746612069099,13.796063548766977,1.874146274784927e-11,0.13204554146907208,113.27432026727902,8.380031918341128,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,372.6,1.94,,,108.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,372.6,1.94,,,54.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,372.6,1.94,,,54.0,13.78,37.36,12.92,31.36,0.00869518,-0.11641375999999999,45.83,1.4693333085365528,13.791920640922594,1.2248298463574979e-10,0.11474051183175148,132.63752299178603,3.656419170362157,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,379.5,1.95,,,54.0,13.78,37.36,12.92,31.36,0.00646282,-0.09706127999999999,45.47,1.3582482065060015,13.796522067652289,1.5254264384190583e-11,0.13382628587789439,111.61596870926047,5.3986989706847215,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,379.5,1.95,,,54.0,13.78,37.36,12.92,31.36,0.00646282,-0.09706127999999999,45.47,1.3582482065060015,13.796522067652289,1.5254264384190583e-11,0.13382628587789439,111.61596870926047,5.3986989706847215,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,379.5,1.95,,,54.0,13.78,37.36,12.92,31.36,0.00646282,-0.09706127999999999,45.47,1.3582482065060015,13.796522067652289,1.5254264384190583e-11,0.13382628587789439,111.61596870926047,5.3986989706847215,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,376.6,2.02,,,66.0,11.42,45.1,10.89,37.2,0.0032889599999999996,-0.12154450000000001,45.71,1.6373626258665515,11.420930929525463,1.244025539972824e-11,0.2606594597357407,3197.590315701259,1.612468862501677,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,375.6,2.02,,,72.0,10.36,49.7,9.84,41.2,0.00381248,-0.12946850000000001,44.1,1.9150965232042887,10.362221161363351,5.534973370073587e-11,0.26961177323810237,1257.530518679656,19.441965047514433,-0.3943,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN405-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036889600000000002,-0.127169,44.3,1.897121790906059,10.485311894009968,5.972624676154759e-11,0.24060985034767018,474.70663113210384,20.807843969991662,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,375.5,1.99,,,72.0,10.48,49.1,9.91,40.9,0.0036889600000000002,-0.127169,44.3,1.897121790906059,10.485311894009968,5.972624676154759e-11,0.24060985034767018,474.70663113210384,20.807843969991662,-0.394,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-72MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,375.0,1.968096,,,72.0,10.43,49.5,9.88,41.0,0.004787370000000001,-0.13325399999999998,46.6,1.8540001772225838,10.43533561437403,2.6273687373196756e-11,0.28258372101983764,552.3915448649208,8.663511168231926,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405-72MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,375.0,1.968096,,,72.0,10.43,49.5,9.88,41.0,0.004787370000000001,-0.13325399999999998,46.6,1.8540001772225838,10.43533561437403,2.6273687373196756e-11,0.28258372101983764,552.3915448649208,8.663511168231926,-0.3588,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-DG-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,381.3,1.95,,,54.0,13.83,37.68,13.07,31.02,0.005504340000000001,-0.09080880000000001,45.74,1.293801298582634,13.845316204571288,3.065375389514896e-12,0.19830634772004152,179.06373483134658,-0.3029219072641457,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,405.0,382.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.0051724200000000005,-0.08949,45.0,1.2889081194830214,13.84556726017829,2.74405170723829e-12,0.19915081787028086,176.92617604009737,0.28743841869994785,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,381.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.006804360000000001,-0.09058272,45.84,1.3083822467781963,13.8445783766596,4.242830571010351e-12,0.19579775336911664,185.74653510266006,2.526189182697892,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,381.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.006804360000000001,-0.09058272,45.84,1.3083822467781963,13.8445783766596,4.242830571010351e-12,0.19579775336911664,185.74653510266006,2.526189182697892,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN405N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,405.0,381.2,1.95,,,54.0,13.83,37.68,13.07,31.02,0.006804360000000001,-0.09058272,45.84,1.3083822467781963,13.8445783766596,4.242830571010351e-12,0.19579775336911664,185.74653510266006,2.526189182697892,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,384.6,1.95,,,54.0,13.86,37.54,13.0,31.55,0.0059875200000000005,-0.09636518,45.36,1.3558496333837677,13.876367476208744,1.2797668507146354e-11,0.13195249334648976,111.73754215669801,5.167720564747154,-0.321,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,384.8,1.95,,,108.0,13.86,37.54,13.0,31.55,0.00708246,-0.09640272,44.9,1.3756630487957653,13.87549178096603,1.9080648595449544e-11,0.1285164299067078,114.97953200577453,8.485991596539227,-0.3263,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,377.3,1.94,,,108.0,13.86,37.54,13.0,31.55,0.00874566,-0.11697464,45.83,1.532064378073455,13.869496256166432,3.109027227773936e-10,0.10201288068886662,148.89010696622137,11.695069715057826,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,377.3,1.94,,,54.0,13.86,37.54,13.0,31.55,0.00874566,-0.11697464,45.83,1.532064378073455,13.869496256166432,3.109027227773936e-10,0.10201288068886662,148.89010696622137,11.695069715057826,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,377.3,1.94,,,54.0,13.86,37.54,13.0,31.55,0.00874566,-0.11697464,45.83,1.532064378073455,13.869496256166432,3.109027227773936e-10,0.10201288068886662,148.89010696622137,11.695069715057826,-0.4043,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,384.3,1.95,,,54.0,13.86,37.54,13.0,31.55,0.006500339999999999,-0.09752891999999999,45.47,1.3653823030323637,13.87594280343068,1.5531547461233478e-11,0.13029702808643345,113.27473383325099,5.502458390829335,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,384.3,1.95,,,54.0,13.86,37.54,13.0,31.55,0.006500339999999999,-0.09752891999999999,45.47,1.3653823030323637,13.87594280343068,1.5531547461233478e-11,0.13029702808643345,113.27473383325099,5.502458390829335,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,384.3,1.95,,,54.0,13.86,37.54,13.0,31.55,0.006500339999999999,-0.09752891999999999,45.47,1.3653823030323637,13.87594280343068,1.5531547461233478e-11,0.13029702808643345,113.27473383325099,5.502458390829335,-0.323,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,381.3,2.02,,,66.0,11.5,45.3,10.97,37.4,0.003312,-0.1220835,45.71,1.6451276102718477,11.500680921116336,1.2637382423917212e-11,0.2563386208011133,4329.270482505061,1.6833565437041234,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,380.4,2.02,,,72.0,10.44,49.9,9.91,41.4,0.0038419199999999995,-0.1299895,44.1,1.9241840112185633,10.442686735556379,5.6780524709429845e-11,0.26456859499995916,1028.049192306514,19.616857948034195,-0.3943,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-DG-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,386.2,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00553618,-0.0909775,45.74,1.2963688411060699,13.92288774253693,3.1005945941179914e-12,0.19211369911871218,207.35218715701006,-0.2637539479138423,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,410.0,387.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.005202340000000001,-0.08965624999999999,45.0,1.2914629213591517,13.923125523260081,2.7754343737951974e-12,0.1929545652825111,204.48693397614844,0.3271390522508159,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,386.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00684372,-0.090751,45.84,1.3109837748663669,13.9221895144476,4.29188112352633e-12,0.1896156575549306,216.37890616389151,2.5672999942547468,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,386.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00684372,-0.090751,45.84,1.3109837748663669,13.9221895144476,4.29188112352633e-12,0.1896156575549306,216.37890616389151,2.5672999942547468,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN410N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,410.0,386.0,1.95,,,54.0,13.91,37.75,13.17,31.14,0.00684372,-0.090751,45.84,1.3109837748663669,13.9221895144476,4.29188112352633e-12,0.1896156575549306,216.37890616389151,2.5672999942547468,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,415.0,386.1,2.02,,,66.0,11.57,45.5,11.04,37.6,0.0033321600000000002,-0.12262250000000001,45.71,1.6529247464773928,11.570476362793968,1.2831099691034303e-11,0.2522972220284958,6127.847794270316,1.7578162696880602,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,415.0,391.9,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00523226,-0.09006,45.0,1.2984906587874108,14.003563291645111,2.8667150474542455e-12,0.18844065701439947,194.36910038488818,0.551146848749971,-0.2955,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,415.0,390.8,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00688308,-0.09115968,45.84,1.3181393070383944,14.002628478547619,4.433312158376842e-12,0.18509336632839893,205.04894479386198,2.796000942090115,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,415.0,390.8,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00688308,-0.09115968,45.84,1.3181393070383944,14.002628478547619,4.433312158376842e-12,0.18509336632839893,205.04894479386198,2.796000942090115,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN415N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,415.0,390.8,1.95,,,54.0,13.99,37.92,13.24,31.33,0.00688308,-0.09115968,45.84,1.3181393070383944,14.002628478547619,4.433312158376842e-12,0.18509336632839893,205.04894479386198,2.796000942090115,-0.2965,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,420.0,391.6,2.190284,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,420.0,391.6,2.190284,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,420.0,391.6,2.190284,,,72.0,10.73,49.8,10.13,41.5,0.00570836,-0.133464,45.72,1.8330134717525652,10.738543617035647,1.681009589850072e-11,0.25642993748154735,322.0525026542513,4.955120149417472,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,420.0,396.4,1.952748,,,54.0,13.65,38.27,12.97,32.38,0.00621075,-0.08997277000000001,45.5,1.3289916341441066,13.656676743142729,4.212873397020145e-12,0.12718047374262,260.0090242715147,4.9486751157468865,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,420.0,396.4,1.952748,,,54.0,13.65,38.27,12.97,32.38,0.00621075,-0.08997277000000001,45.5,1.3289916341441066,13.656676743142729,4.212873397020145e-12,0.12718047374262,260.0090242715147,4.9486751157468865,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,420.0,396.4,1.952748,,,54.0,13.65,38.27,12.97,32.38,0.00621075,-0.08997277000000001,45.5,1.3289916341441066,13.656676743142729,4.212873397020145e-12,0.12718047374262,260.0090242715147,4.9486751157468865,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,420.0,396.4,1.952748,,,54.0,13.65,38.27,12.97,32.38,0.00621075,-0.08997277000000001,45.5,1.3289916341441066,13.656676743142729,4.212873397020145e-12,0.12718047374262,260.0090242715147,4.9486751157468865,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,420.0,396.4,1.952748,,,54.0,13.65,38.27,12.97,32.38,0.00621075,-0.08997277000000001,45.5,1.3289916341441066,13.656676743142729,4.212873397020145e-12,0.12718047374262,260.0090242715147,4.9486751157468865,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,420.0,396.4,1.95275,,,54.0,13.65,38.27,12.97,32.38,0.0044226000000000005,-0.09004931000000001,44.9,1.3225258972039353,13.656874702427386,3.658867565552696e-12,0.1283256130580555,254.7957005594675,3.837374693090262,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,420.0,396.4,1.95275,,,54.0,13.65,38.27,12.97,32.38,0.0044226000000000005,-0.09004931000000001,44.9,1.3225258972039353,13.656874702427386,3.658867565552696e-12,0.1283256130580555,254.7957005594675,3.837374693090262,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN420N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,420.0,396.4,1.95275,,,54.0,13.65,38.27,12.97,32.38,0.0044226000000000005,-0.09004931000000001,44.9,1.3225258972039353,13.656874702427386,3.658867565552696e-12,0.1283256130580555,254.7957005594675,3.837374693090262,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,425.0,396.4,2.190284,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,425.0,396.4,2.190284,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,425.0,396.4,2.190284,,,72.0,11.11,49.0,10.52,40.4,0.005910519999999999,-0.13132,45.72,1.7794608568892707,11.110020638386356,1.2211892662604499e-11,0.29353595895955065,158015.96984463424,1.92329254727491,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,401.2,1.952748,,,54.0,13.7,38.56,13.02,32.64,0.0062334999999999995,-0.09065456000000001,45.5,1.3392272516146417,13.706514653249288,4.2441015157551715e-12,0.12641563453247925,265.8459522154763,4.980225571557739,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,401.2,1.952748,,,54.0,13.7,38.56,13.02,32.64,0.0062334999999999995,-0.09065456000000001,45.5,1.3392272516146417,13.706514653249288,4.2441015157551715e-12,0.12641563453247925,265.8459522154763,4.980225571557739,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,401.2,1.952748,,,54.0,13.7,38.56,13.02,32.64,0.0062334999999999995,-0.09065456000000001,45.5,1.3392272516146417,13.706514653249288,4.2441015157551715e-12,0.12641563453247925,265.8459522154763,4.980225571557739,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,401.2,1.952748,,,54.0,13.7,38.56,13.02,32.64,0.0062334999999999995,-0.09065456000000001,45.5,1.3392272516146417,13.706514653249288,4.2441015157551715e-12,0.12641563453247925,265.8459522154763,4.980225571557739,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-DG-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,400.6,1.95,,,54.0,14.16,38.4,13.4,31.72,0.0056356800000000006,-0.092544,45.74,1.3198408421064967,14.173590773514794,3.2351486379926135e-12,0.18825054902196878,196.13510412053535,-0.05728052805048184,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,425.0,401.2,1.952748,,,54.0,13.7,38.56,13.02,32.64,0.0062334999999999995,-0.09065456000000001,45.5,1.3392272516146417,13.706514653249288,4.2441015157551715e-12,0.12641563453247925,265.8459522154763,4.980225571557739,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,425.0,401.3,1.95275,,,54.0,13.7,38.56,13.02,32.64,0.004438799999999999,-0.09073168000000002,44.9,1.3327103550573975,13.706710810950533,3.685944065465712e-12,0.12756571572142444,260.4231174420929,3.8684116644261795,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,425.0,401.3,1.95275,,,54.0,13.7,38.56,13.02,32.64,0.004438799999999999,-0.09073168000000002,44.9,1.3327103550573975,13.706710810950533,3.685944065465712e-12,0.12756571572142444,260.4231174420929,3.8684116644261795,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN425N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,425.0,401.3,1.95275,,,54.0,13.7,38.56,13.02,32.64,0.004438799999999999,-0.09073168000000002,44.9,1.3327103550573975,13.706710810950533,3.685944065465712e-12,0.12756571572142444,260.4231174420929,3.8684116644261795,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,395.2,2.15,,,60.0,13.25,41.34,12.54,34.3,0.0058962500000000004,-0.12063012000000002,46.56,1.5921284576770103,13.256235181456885,6.952812262323116e-11,0.17305428512211307,367.74701363432195,6.330491113018672,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,395.2,2.15,,,60.0,13.25,41.34,12.54,34.3,0.0058962500000000004,-0.12063012000000002,46.56,1.5921284576770103,13.256235181456885,6.952812262323116e-11,0.17305428512211307,367.74701363432195,6.330491113018672,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,395.2,2.15,,,60.0,13.25,41.34,12.54,34.3,0.0058962500000000004,-0.12063012000000002,46.56,1.5921284576770103,13.256235181456885,6.952812262323116e-11,0.17305428512211307,367.74701363432195,6.330491113018672,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,399.5,2.19,,,72.0,11.2,48.6,10.65,40.4,0.005667199999999999,-0.13617720000000003,45.73,1.8180253111844236,11.20268608795852,2.7401280751950135e-11,0.2433949386125851,1014.867514091067,4.048255497691683,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,400.7,2.2048720000000004,,,72.0,11.2,48.6,10.65,40.4,0.0058464,-0.12864420000000001,46.18,1.7736195709576112,11.203608812022006,1.4014831304133904e-11,0.25259689697451,783.9381137137947,4.3315520029135905,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,401.2,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,401.2,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,401.2,2.190284,,,72.0,11.19,49.2,10.6,40.6,0.0059530799999999995,-0.13185600000000003,45.72,1.787649280320504,11.190014744490227,1.247648708350919e-11,0.28874519406058013,219137.19575354352,2.04179178443742,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,398.9,2.19,,,72.0,11.19,49.2,10.6,40.6,0.00527049,-0.14676360000000002,44.98,1.8800659020736352,11.194850829531145,4.794696655728636e-11,0.26988971049303595,622.5875306251897,2.2759858698975215,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,406.0,1.952748,,,54.0,13.75,38.84,13.08,32.88,0.0062562500000000005,-0.09131284,45.5,1.3484274192480161,13.75582243090828,4.216802671888526e-12,0.126682234447092,299.1672643974524,4.888372199681705,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,406.0,1.952748,,,54.0,13.75,38.84,13.08,32.88,0.0062562500000000005,-0.09131284,45.5,1.3484274192480161,13.75582243090828,4.216802671888526e-12,0.126682234447092,299.1672643974524,4.888372199681705,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,406.0,1.952748,,,54.0,13.75,38.84,13.08,32.88,0.0062562500000000005,-0.09131284,45.5,1.3484274192480161,13.75582243090828,4.216802671888526e-12,0.126682234447092,299.1672643974524,4.888372199681705,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,406.0,1.952748,,,54.0,13.75,38.84,13.08,32.88,0.0062562500000000005,-0.09131284,45.5,1.3484274192480161,13.75582243090828,4.216802671888526e-12,0.126682234447092,299.1672643974524,4.888372199681705,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-DG-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,405.5,1.95,,,54.0,14.24,38.5,13.5,31.89,0.0056675200000000005,-0.09278499999999999,45.74,1.3239321752698896,14.251239996942255,3.306626761412145e-12,0.18030592268442938,228.43032693597172,0.06981174147798092,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,430.0,406.0,1.952748,,,54.0,13.75,38.84,13.08,32.88,0.0062562500000000005,-0.09131284,45.5,1.3484274192480161,13.75582243090828,4.216802671888526e-12,0.126682234447092,299.1672643974524,4.888372199681705,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,406.1,1.95275,,,54.0,13.75,38.84,13.08,32.88,0.004455,-0.09139052,44.9,1.3418663667628876,13.75601274503035,3.6620814023951835e-12,0.12783461799663473,292.3333649558696,3.777069678976046,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,406.1,1.95275,,,54.0,13.75,38.84,13.08,32.88,0.004455,-0.09139052,44.9,1.3418663667628876,13.75601274503035,3.6620814023951835e-12,0.12783461799663473,292.3333649558696,3.777069678976046,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN430N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,430.0,406.1,1.95275,,,54.0,13.75,38.84,13.08,32.88,0.004455,-0.09139052,44.9,1.3418663667628876,13.75601274503035,3.6620814023951835e-12,0.12783461799663473,292.3333649558696,3.777069678976046,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,409.2,2.16,,,60.0,13.33,41.52,12.63,34.45,0.00577189,-0.1067064,43.93,1.490712712226762,13.338726701729245,1.057556687698538e-11,0.19151918478403795,292.5447468005577,3.7011245573702896,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,399.9,2.15,,,60.0,13.33,41.52,12.63,34.45,0.00593185,-0.12115536,46.56,1.613343299629351,13.334795363126954,8.818318798471739e-11,0.17018796504687186,473.0831939225936,8.327517289854415,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,399.9,2.15,,,60.0,13.33,41.52,12.63,34.45,0.00593185,-0.12115536,46.56,1.613343299629351,13.334795363126954,8.818318798471739e-11,0.17018796504687186,473.0831939225936,8.327517289854415,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,399.9,2.15,,,60.0,13.33,41.52,12.63,34.45,0.00593185,-0.12115536,46.56,1.613343299629351,13.334795363126954,8.818318798471739e-11,0.17018796504687186,473.0831939225936,8.327517289854415,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,407.0,2.16,,,60.0,13.33,41.52,12.63,34.45,0.0053986500000000005,-0.10654032000000001,45.38,1.4916947863268362,13.338692063936747,1.0771606651727745e-11,0.1913457977021821,293.4446314248671,4.058144131840831,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,407.0,2.16,,,60.0,13.33,41.52,12.63,34.45,0.0053986500000000005,-0.10654032000000001,45.38,1.4916947863268362,13.338692063936747,1.0771606651727745e-11,0.1913457977021821,293.4446314248671,4.058144131840831,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,407.0,2.16,,,60.0,13.33,41.52,12.63,34.45,0.0053986500000000005,-0.10654032000000001,45.38,1.4916947863268362,13.338692063936747,1.0771606651727745e-11,0.1913457977021821,293.4446314248671,4.058144131840831,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,404.3,2.19,,,72.0,11.28,48.8,10.72,40.6,0.00570768,-0.1367376,45.73,1.8202240652369313,11.280009835601975,2.5639941656017372e-11,0.2402188702954857,274907.3634086092,3.4159122983871115,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,405.4,2.2048720000000004,,,72.0,11.28,48.8,10.72,40.6,0.00588816,-0.1291736,46.18,1.7821323295289642,11.284085713182504,1.4370187416705828e-11,0.24818858603407964,685.2089620092718,4.486572628156489,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,406.0,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,406.0,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,406.0,2.190284,,,72.0,11.26,49.4,10.67,40.8,0.00599032,-0.132392,45.72,1.8068769682108525,11.266532134746168,1.4936571960596687e-11,0.2822128066057134,486.4743855588518,3.525780294432378,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,403.6,2.19,,,72.0,11.26,49.4,10.67,40.8,0.00530346,-0.1473602,44.98,1.8882412879449966,11.264577834160622,4.8620070659406e-11,0.2655369284448706,653.1354523618227,2.338540167628048,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.9,1.952748,,,54.0,13.8,39.12,13.13,33.13,0.006279000000000001,-0.09197112,45.5,1.358282723113045,13.805674525321956,4.2449891838647775e-12,0.12602708234287777,306.487968859497,4.913881559268299,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.9,1.952748,,,54.0,13.8,39.12,13.13,33.13,0.006279000000000001,-0.09197112,45.5,1.358282723113045,13.805674525321956,4.2449891838647775e-12,0.12602708234287777,306.487968859497,4.913881559268299,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.9,1.952748,,,54.0,13.8,39.12,13.13,33.13,0.006279000000000001,-0.09197112,45.5,1.358282723113045,13.805674525321956,4.2449891838647775e-12,0.12602708234287777,306.487968859497,4.913881559268299,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.9,1.952748,,,54.0,13.8,39.12,13.13,33.13,0.006279000000000001,-0.09197112,45.5,1.358282723113045,13.805674525321956,4.2449891838647775e-12,0.12602708234287777,306.487968859497,4.913881559268299,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-DG-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.3,1.95,,,54.0,14.3,38.63,13.57,32.06,0.005691400000000001,-0.09309830000000001,45.74,1.3191589146092793,14.30000471684957,2.74151864908484e-12,0.1763373798547756,534601.102395029,-0.718454325096809,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,435.0,410.9,1.952748,,,54.0,13.8,39.12,13.13,33.13,0.006279000000000001,-0.09197112,45.5,1.358282723113045,13.805674525321956,4.2449891838647775e-12,0.12602708234287777,306.487968859497,4.913881559268299,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,410.9,1.95275,,,54.0,13.8,39.12,13.13,33.13,0.0044712,-0.09204936,44.9,1.3516725291621616,13.80586318966766,3.6865175618295505e-12,0.1271839458905359,299.348742946573,3.802143532198035,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,410.9,1.95275,,,54.0,13.8,39.12,13.13,33.13,0.0044712,-0.09204936,44.9,1.3516725291621616,13.80586318966766,3.6865175618295505e-12,0.1271839458905359,299.348742946573,3.802143532198035,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN435N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,435.0,410.9,1.95275,,,54.0,13.8,39.12,13.13,33.13,0.0044712,-0.09204936,44.9,1.3516725291621616,13.80586318966766,3.6865175618295505e-12,0.1271839458905359,299.348742946573,3.802143532198035,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,414.0,2.16,,,60.0,13.41,41.7,12.72,34.6,0.00580653,-0.10716900000000001,43.93,1.496413902814771,13.417642287469423,1.050301767735718e-11,0.1911829427473159,335.47066755350085,3.5874241076380584,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,404.6,2.15,,,60.0,13.41,41.7,12.72,34.6,0.00596745,-0.12168060000000001,46.56,1.619448778462557,13.41381175025658,8.758330054534188e-11,0.16993776900969104,597.8528210208807,8.211066807466228,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,404.6,2.15,,,60.0,13.41,41.7,12.72,34.6,0.00596745,-0.12168060000000001,46.56,1.619448778462557,13.41381175025658,8.758330054534188e-11,0.16993776900969104,597.8528210208807,8.211066807466228,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,404.6,2.15,,,60.0,13.41,41.7,12.72,34.6,0.00596745,-0.12168060000000001,46.56,1.619448778462557,13.41381175025658,8.758330054534188e-11,0.16993776900969104,597.8528210208807,8.211066807466228,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,411.7,2.16,,,60.0,13.41,41.7,12.72,34.6,0.00543105,-0.1070022,45.38,1.4973995812238494,13.41760844489767,1.0697783193845788e-11,0.1910101914121206,336.6583734722438,3.944148306471422,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,411.7,2.16,,,60.0,13.41,41.7,12.72,34.6,0.00543105,-0.1070022,45.38,1.4973995812238494,13.41760844489767,1.0697783193845788e-11,0.1910101914121206,336.6583734722438,3.944148306471422,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,411.7,2.16,,,60.0,13.41,41.7,12.72,34.6,0.00543105,-0.1070022,45.38,1.4973995812238494,13.41760844489767,1.0697783193845788e-11,0.1910101914121206,336.6583734722438,3.944148306471422,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,409.1,2.19,,,72.0,11.36,49.0,10.79,40.8,0.0057481599999999996,-0.137298,45.73,1.835545722299805,11.363600735843491,2.880463272260888e-11,0.23464058188946083,740.2693984723514,4.355292070002174,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,410.2,2.2048720000000004,,,72.0,11.36,49.0,10.79,40.8,0.00592992,-0.12970299999999998,46.18,1.7906468120454178,11.364546684070904,1.4731730898878516e-11,0.24383738356960658,609.2336013054614,4.640564388186096,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,410.8,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,410.8,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,410.8,2.190284,,,72.0,11.34,49.6,10.74,41.0,0.00603288,-0.13292800000000002,45.72,1.8033567609875503,11.340009493621519,1.2872347572833458e-11,0.27986270283072606,334294.32051212766,2.1908819076164776,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,408.4,2.19,,,72.0,11.34,49.6,10.74,41.0,0.00534114,-0.14795680000000003,44.98,1.8972537865484378,11.345056205822937,4.9861783802593346e-11,0.260934028363874,585.2198456503322,2.4909065664719776,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.7,1.952748,,,54.0,13.85,39.38,13.18,33.37,0.00630175,-0.09258238,45.5,1.367575410727905,13.855512770815775,4.2849332906109345e-12,0.12471619720677793,313.3305392019707,4.96299498987436,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.7,1.952748,,,54.0,13.85,39.38,13.18,33.37,0.00630175,-0.09258238,45.5,1.367575410727905,13.855512770815775,4.2849332906109345e-12,0.12471619720677793,313.3305392019707,4.96299498987436,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.7,1.952748,,,54.0,13.85,39.38,13.18,33.37,0.00630175,-0.09258238,45.5,1.367575410727905,13.855512770815775,4.2849332906109345e-12,0.12471619720677793,313.3305392019707,4.96299498987436,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.7,1.952748,,,54.0,13.85,39.38,13.18,33.37,0.00630175,-0.09258238,45.5,1.367575410727905,13.855512770815775,4.2849332906109345e-12,0.12471619720677793,313.3305392019707,4.96299498987436,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-DG-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.1,1.95,,,54.0,14.37,38.79,13.64,32.26,0.00571926,-0.09348390000000001,45.74,1.335705321102448,14.379609263937855,3.473898120332218e-12,0.16920182733645123,253.02981467197267,0.3993414927757419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,415.7,1.952748,,,54.0,13.85,39.38,13.18,33.37,0.00630175,-0.09258238,45.5,1.367575410727905,13.855512770815775,4.2849332906109345e-12,0.12471619720677793,313.3305392019707,4.96299498987436,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,415.8,1.95275,,,54.0,13.85,39.38,13.18,33.37,0.0044874,-0.09266114000000002,44.9,1.3609180940838823,13.855699196299943,3.7211582865032826e-12,0.12587732418448244,305.9029469422849,3.850533265275592,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,415.8,1.95275,,,54.0,13.85,39.38,13.18,33.37,0.0044874,-0.09266114000000002,44.9,1.3609180940838823,13.855699196299943,3.7211582865032826e-12,0.12587732418448244,305.9029469422849,3.850533265275592,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,440.0,415.8,1.95275,,,54.0,13.85,39.38,13.18,33.37,0.0044874,-0.09266114000000002,44.9,1.3609180940838823,13.855699196299943,3.7211582865032826e-12,0.12587732418448244,305.9029469422849,3.850533265275592,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-96BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,416.4,1.998108,,,48.0,15.95,34.77,14.81,29.72,0.007751699999999999,-0.08417817000000002,44.91,1.2284105154459128,15.970943219050147,7.826344078184205e-12,0.07394362406910149,56.314208517257946,5.919619340448151,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-96BMHR-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,416.4,1.998108,,,48.0,15.95,34.77,14.81,29.72,0.007751699999999999,-0.08417817000000002,44.91,1.2284105154459128,15.970943219050147,7.826344078184205e-12,0.07394362406910149,56.314208517257946,5.919619340448151,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-96BMHR-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,416.4,1.998108,,,48.0,15.95,34.77,14.81,29.72,0.007751699999999999,-0.08417817000000002,44.91,1.2284105154459128,15.970943219050147,7.826344078184205e-12,0.07394362406910149,56.314208517257946,5.919619340448151,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN440N-96BMHR-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,440.0,416.4,1.998108,,,48.0,15.95,34.77,14.81,29.72,0.007751699999999999,-0.08417817000000002,44.91,1.2284105154459128,15.970943219050147,7.826344078184205e-12,0.07394362406910149,56.314208517257946,5.919619340448151,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,418.8,2.16,,,60.0,13.48,41.9,12.79,34.8,0.00583684,-0.107683,43.93,1.5041174270821331,13.4873491750844,1.0663844040172276e-11,0.1880649865664517,344.95246156783975,3.6710142415164793,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,409.4,2.15,,,60.0,13.48,41.9,12.79,34.8,0.0059986,-0.1222642,46.56,1.62782945928214,13.483581439618519,8.891980851388694e-11,0.16680585810791956,627.8322044595343,8.296916037012311,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,409.4,2.15,,,60.0,13.48,41.9,12.79,34.8,0.0059986,-0.1222642,46.56,1.62782945928214,13.483581439618519,8.891980851388694e-11,0.16680585810791956,627.8322044595343,8.296916037012311,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,409.4,2.15,,,60.0,13.48,41.9,12.79,34.8,0.0059986,-0.1222642,46.56,1.62782945928214,13.483581439618519,8.891980851388694e-11,0.16680585810791956,627.8322044595343,8.296916037012311,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,416.5,2.16,,,60.0,13.48,41.9,12.79,34.8,0.0054594000000000005,-0.1075154,45.38,1.5051075101544367,13.487315860813844,1.0861387030883817e-11,0.18789229973640767,346.2050853801689,4.027792584785421,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,416.5,2.16,,,60.0,13.48,41.9,12.79,34.8,0.0054594000000000005,-0.1075154,45.38,1.5051075101544367,13.487315860813844,1.0861387030883817e-11,0.18789229973640767,346.2050853801689,4.027792584785421,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,416.5,2.16,,,60.0,13.48,41.9,12.79,34.8,0.0054594000000000005,-0.1075154,45.38,1.5051075101544367,13.487315860813844,1.0861387030883817e-11,0.18789229973640767,346.2050853801689,4.027792584785421,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,413.9,2.19,,,72.0,11.44,49.2,10.86,41.0,0.00578864,-0.13785840000000002,45.73,1.835639702713268,11.440008104073144,2.619266198324467e-11,0.2319581994411014,327443.93842825794,3.4766142069454764,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,415.0,2.2048720000000004,,,72.0,11.44,49.2,10.86,41.0,0.00597168,-0.1302324,46.18,1.7991560127923258,11.444992006744556,1.5097907470607593e-11,0.23954361297106808,548.9533773374214,4.792628652127338,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,415.6,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,415.6,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,415.6,2.190284,,,72.0,11.42,49.8,10.81,41.2,0.00607544,-0.133464,45.72,1.810913455538561,11.4200102936855,1.3019395845369893e-11,0.2754923330688611,305637.9636367335,2.226936784571032,-0.3326,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,413.2,2.19,,,72.0,11.42,49.8,10.81,41.2,0.00537882,-0.1485534,44.98,1.9062517042541267,11.42551877120591,5.1113795843111405e-11,0.2563939564561264,530.556345451086,2.640399571912938,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,420.5,1.952748,,,54.0,13.9,39.64,13.24,33.61,0.0063245,-0.09319364000000001,45.5,1.3763976112190688,13.904808205942338,4.286282285392576e-12,0.12347541713780012,356.9539914054325,4.930304542160549,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,420.5,1.952748,,,54.0,13.9,39.64,13.24,33.61,0.0063245,-0.09319364000000001,45.5,1.3763976112190688,13.904808205942338,4.286282285392576e-12,0.12347541713780012,356.9539914054325,4.930304542160549,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,420.5,1.952748,,,54.0,13.9,39.64,13.24,33.61,0.0063245,-0.09319364000000001,45.5,1.3763976112190688,13.904808205942338,4.286282285392576e-12,0.12347541713780012,356.9539914054325,4.930304542160549,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,420.5,1.952748,,,54.0,13.9,39.64,13.24,33.61,0.0063245,-0.09319364000000001,45.5,1.3763976112190688,13.904808205942338,4.286282285392576e-12,0.12347541713780012,356.9539914054325,4.930304542160549,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,420.5,1.952748,,,54.0,13.9,39.64,13.24,33.61,0.0063245,-0.09319364000000001,45.5,1.3763976112190688,13.904808205942338,4.286282285392576e-12,0.12347541713780012,356.9539914054325,4.930304542160549,-0.2922,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,420.6,1.95275,,,54.0,13.9,39.64,13.24,33.61,0.0045036,-0.09327292000000001,44.9,1.3696962467119573,13.904987388647543,3.7221629089445496e-12,0.12463915919006438,347.3730320623914,3.817643242987549,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,420.6,1.95275,,,54.0,13.9,39.64,13.24,33.61,0.0045036,-0.09327292000000001,44.9,1.3696962467119573,13.904987388647543,3.7221629089445496e-12,0.12463915919006438,347.3730320623914,3.817643242987549,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,445.0,420.6,1.95275,,,54.0,13.9,39.64,13.24,33.61,0.0045036,-0.09327292000000001,44.9,1.3696962467119573,13.904987388647543,3.7221629089445496e-12,0.12463915919006438,347.3730320623914,3.817643242987549,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-96BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,421.3,1.998108,,,48.0,16.0,34.95,14.89,29.9,0.007776,-0.08461395000000001,44.91,1.2339395165566676,16.01912919272907,7.722631156427628e-12,0.07232382034531426,60.49294095414812,5.7667145164595786,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-96BMHR-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,421.3,1.998108,,,48.0,16.0,34.95,14.89,29.9,0.007776,-0.08461395000000001,44.91,1.2339395165566676,16.01912919272907,7.722631156427628e-12,0.07232382034531426,60.49294095414812,5.7667145164595786,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-96BMHR-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,421.3,1.998108,,,48.0,16.0,34.95,14.89,29.9,0.007776,-0.08461395000000001,44.91,1.2339395165566676,16.01912919272907,7.722631156427628e-12,0.07232382034531426,60.49294095414812,5.7667145164595786,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN445N-96BMHR-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,445.0,421.3,1.998108,,,48.0,16.0,34.95,14.89,29.9,0.007776,-0.08461395000000001,44.91,1.2339395165566676,16.01912919272907,7.722631156427628e-12,0.07232382034531426,60.49294095414812,5.7667145164595786,-0.2891,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,423.7,2.16,,,60.0,13.56,42.1,12.86,35.0,0.00587148,-0.10819700000000002,43.93,1.5123381202265513,13.567801177394967,1.0927956435044396e-11,0.1848143086351193,321.24407813547526,3.8303802847202175,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,414.1,2.15,,,60.0,13.56,42.1,12.86,35.0,0.0060342,-0.12284780000000001,46.56,1.6368138222174828,13.564010985536052,9.111379598780514e-11,0.1635231358933826,552.8251970581605,8.46037985969991,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,421.3,2.16,,,60.0,13.56,42.1,12.86,35.0,0.0054918,-0.1080286,45.38,1.5133330684404604,13.567767700919804,1.1130138602109628e-11,0.18464157750332372,322.32700906062394,4.187413300842247,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,421.3,2.16,,,60.0,13.56,42.1,12.86,35.0,0.0054918,-0.1080286,45.38,1.5133330684404604,13.567767700919804,1.1130138602109628e-11,0.18464157750332372,322.32700906062394,4.187413300842247,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,421.3,2.16,,,60.0,13.56,42.1,12.86,35.0,0.0054918,-0.1080286,45.38,1.5133330684404604,13.567767700919804,1.1130138602109628e-11,0.18464157750332372,322.32700906062394,4.187413300842247,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,418.6,2.19,,,72.0,11.52,49.4,10.93,41.2,0.00582912,-0.1384188,45.73,1.84335367378993,11.520008773206037,2.647262677155741e-11,0.22790756309998217,299265.75425745465,3.5073354506376067,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,419.8,2.2048720000000004,,,72.0,11.52,49.4,10.93,41.2,0.00601344,-0.13076179999999998,46.18,1.7969841838686,11.520009160393652,1.325783494709557e-11,0.2372942764143096,298419.95043445873,3.6040100690140706,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,418.0,2.19,,,72.0,11.5,50.0,10.87,41.4,0.0054165,-0.14915,44.98,1.9161363038771329,11.506721901532531,5.296536614657178e-11,0.2518223672154385,430.8241186779031,2.883617754542802,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,425.5,1.95275,,,54.0,13.96,39.92,13.29,33.87,0.00452304,-0.09393176,44.9,1.3801326894958024,13.965351688808306,3.795807728805473e-12,0.12301264172548537,320.8812284892095,3.95133717497021,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,425.5,1.95275,,,54.0,13.96,39.92,13.29,33.87,0.00452304,-0.09393176,44.9,1.3801326894958024,13.965351688808306,3.795807728805473e-12,0.12301264172548537,320.8812284892095,3.95133717497021,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,450.0,425.5,1.95275,,,54.0,13.96,39.92,13.29,33.87,0.00452304,-0.09393176,44.9,1.3801326894958024,13.965351688808306,3.795807728805473e-12,0.12301264172548537,320.8812284892095,3.95133717497021,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-96BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,426.1,1.998108,,,48.0,16.05,35.13,14.97,30.07,0.0078003,-0.08504973000000002,44.91,1.2392706776474307,16.06756715313291,7.587135113410291e-12,0.07148046031059462,65.30718893350752,5.576171516380574,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-96BMHR-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,426.1,1.998108,,,48.0,16.05,35.13,14.97,30.07,0.0078003,-0.08504973000000002,44.91,1.2392706776474307,16.06756715313291,7.587135113410291e-12,0.07148046031059462,65.30718893350752,5.576171516380574,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-96BMHR-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,426.1,1.998108,,,48.0,16.05,35.13,14.97,30.07,0.0078003,-0.08504973000000002,44.91,1.2392706776474307,16.06756715313291,7.587135113410291e-12,0.07148046031059462,65.30718893350752,5.576171516380574,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN450N-96BMHR-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,450.0,426.1,1.998108,,,48.0,16.05,35.13,14.97,30.07,0.0078003,-0.08504973000000002,44.91,1.2392706776474307,16.06756715313291,7.587135113410291e-12,0.07148046031059462,65.30718893350752,5.576171516380574,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,428.5,2.16,,,60.0,13.63,42.3,12.93,35.2,0.00590179,-0.108711,43.93,1.5200406617634454,13.637509078403095,1.109169360309733e-11,0.1817655517573986,329.929234091778,3.9118832203686282,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,418.9,2.15,,,60.0,13.63,42.3,12.93,35.2,0.00606535,-0.1234314,46.56,1.6451934073675574,13.63378136319504,9.24742581496831e-11,0.16046086785101957,578.3844779405714,8.544093812852664,-0.3891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,426.2,2.16,,,60.0,13.63,42.3,12.93,35.2,0.005520150000000001,-0.1085418,45.38,1.5210400516687512,13.637476124130984,1.1296704852342437e-11,0.18159287856365475,331.06873393514866,4.268974036784049,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,426.2,2.16,,,60.0,13.63,42.3,12.93,35.2,0.005520150000000001,-0.1085418,45.38,1.5210400516687512,13.637476124130984,1.1296704852342437e-11,0.18159287856365475,331.06873393514866,4.268974036784049,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,426.2,2.16,,,60.0,13.63,42.3,12.93,35.2,0.005520150000000001,-0.1085418,45.38,1.5210400516687512,13.637476124130984,1.1296704852342437e-11,0.18159287856365475,331.06873393514866,4.268974036784049,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,423.4,2.19,,,72.0,11.6,49.6,11.0,41.4,0.005869599999999999,-0.13897920000000002,45.73,1.8618220979285522,11.604855100128345,3.099365329859322e-11,0.22192959770729734,530.2431081577184,4.806119732765015,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,424.6,2.2048720000000004,,,72.0,11.6,49.6,11.0,41.4,0.0060552,-0.1312912,46.18,1.8045042992712832,11.600007575524174,1.339982873294223e-11,0.23328450508339485,357218.4381162309,3.6355084633908232,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,422.7,2.19,,,72.0,11.59,50.2,10.94,41.6,0.00545889,-0.1497466,44.98,1.9091375236611716,11.5900096489581,4.410416118224227e-11,0.25016704912266197,300497.0417688551,1.278701246257845,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-108MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,430.3,1.95275,,,54.0,14.02,40.16,13.35,34.09,0.00454248,-0.09449648,44.9,1.3886042928203708,14.025182635477455,3.826783453567339e-12,0.1218504919452826,329.6284116394381,3.983332517722803,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-108MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,430.3,1.95275,,,54.0,14.02,40.16,13.35,34.09,0.00454248,-0.09449648,44.9,1.3886042928203708,14.025182635477455,3.826783453567339e-12,0.1218504919452826,329.6284116394381,3.983332517722803,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-108MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,455.0,430.3,1.95275,,,54.0,14.02,40.16,13.35,34.09,0.00454248,-0.09449648,44.9,1.3886042928203708,14.025182635477455,3.826783453567339e-12,0.1218504919452826,329.6284116394381,3.983332517722803,-0.3004,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-96BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,431.0,1.998108,,,48.0,16.1,35.31,15.04,30.26,0.0078246,-0.08548551000000001,44.91,1.2454010222660943,16.116098657900043,7.585909054576925e-12,0.06906655520521318,69.07231313641927,5.541244648893728,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-96BMHR-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,431.0,1.998108,,,48.0,16.1,35.31,15.04,30.26,0.0078246,-0.08548551000000001,44.91,1.2454010222660943,16.116098657900043,7.585909054576925e-12,0.06906655520521318,69.07231313641927,5.541244648893728,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-96BMHR-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,431.0,1.998108,,,48.0,16.1,35.31,15.04,30.26,0.0078246,-0.08548551000000001,44.91,1.2454010222660943,16.116098657900043,7.585909054576925e-12,0.06906655520521318,69.07231313641927,5.541244648893728,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN455N-96BMHR-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,455.0,431.0,1.998108,,,48.0,16.1,35.31,15.04,30.26,0.0078246,-0.08548551000000001,44.91,1.2454010222660943,16.116098657900043,7.585909054576925e-12,0.06906655520521318,69.07231313641927,5.541244648893728,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,433.3,2.16,,,60.0,13.71,42.5,13.0,35.4,0.0059364299999999995,-0.109225,43.93,1.5282618315478014,13.71793647039723,1.1361848299621918e-11,0.17858415072320988,308.49843793608926,4.068694132036203,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,431.0,2.16,,,60.0,13.71,42.5,13.0,35.4,0.00555255,-0.109055,45.38,1.529266147237554,13.71790334776842,1.1571607656246678e-11,0.17841142375549293,309.49171238183897,4.426044977096191,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,431.0,2.16,,,60.0,13.71,42.5,13.0,35.4,0.00555255,-0.109055,45.38,1.529266147237554,13.71790334776842,1.1571607656246678e-11,0.17841142375549293,309.49171238183897,4.426044977096191,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,431.0,2.16,,,60.0,13.71,42.5,13.0,35.4,0.00555255,-0.109055,45.38,1.529266147237554,13.71790334776842,1.1571607656246678e-11,0.17841142375549293,309.49171238183897,4.426044977096191,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,428.2,2.19,,,72.0,11.67,49.8,11.06,41.6,0.0059050199999999995,-0.1395396,45.73,1.8587443695151087,11.670006538318638,2.6997709953783426e-11,0.22016074964191015,392961.5160338726,3.5635598368031367,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,429.4,2.2048720000000004,,,72.0,11.67,49.8,11.06,41.6,0.00609174,-0.13182059999999998,46.18,1.8119950337359891,11.670006808861357,1.3524640770911125e-11,0.22953156131228208,393406.6492862048,3.662985431955832,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,427.5,2.19,,,72.0,11.67,50.4,11.01,41.8,0.00549657,-0.1503432,44.98,1.9170365782036045,11.670007377528737,4.458751703140612e-11,0.24598391363436045,389113.0187237773,1.3115778543418937,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,437.5,2.163672,,,60.0,13.63,41.97,12.94,35.55,0.006883150000000001,-0.10014042000000001,44.9,1.4132819856461487,13.638496613987229,1.7052283303001124e-12,0.14428155793882422,231.4519218014214,-4.132094929068975,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,437.5,2.163672,,,60.0,13.63,41.97,12.94,35.55,0.006883150000000001,-0.10014042000000001,44.9,1.4132819856461487,13.638496613987229,1.7052283303001124e-12,0.14428155793882422,231.4519218014214,-4.132094929068975,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,437.5,2.163672,,,60.0,13.63,41.97,12.94,35.55,0.006883150000000001,-0.10014042000000001,44.9,1.4132819856461487,13.638496613987229,1.7052283303001124e-12,0.14428155793882422,231.4519218014214,-4.132094929068975,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,437.5,2.163672,,,60.0,13.63,41.97,12.94,35.55,0.006883150000000001,-0.10014042000000001,44.9,1.4132819856461487,13.638496613987229,1.7052283303001124e-12,0.14428155793882422,231.4519218014214,-4.132094929068975,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,437.5,2.163672,,,60.0,13.63,41.97,12.94,35.55,0.006883150000000001,-0.10014042000000001,44.9,1.4132819856461487,13.638496613987229,1.7052283303001124e-12,0.14428155793882422,231.4519218014214,-4.132094929068975,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,429.0,2.16,,,60.0,13.63,41.97,12.94,35.55,0.0054792600000000006,-0.11634084,45.75,1.555989012848204,13.63468953437316,2.608886018035842e-11,0.11910437430681582,346.1735238410123,3.2657725711456354,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,429.0,2.16,,,60.0,13.63,41.97,12.94,35.55,0.0054792600000000006,-0.11634084,45.75,1.555989012848204,13.63468953437316,2.608886018035842e-11,0.11910437430681582,346.1735238410123,3.2657725711456354,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,460.0,429.0,2.16,,,60.0,13.63,41.97,12.94,35.55,0.0054792600000000006,-0.11634084,45.75,1.555989012848204,13.63468953437316,2.608886018035842e-11,0.11910437430681582,346.1735238410123,3.2657725711456354,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-96BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,435.8,1.998108,,,48.0,16.15,35.49,15.12,30.44,0.007848899999999999,-0.08592129000000001,44.91,1.2509324384021059,16.164490572460522,7.488594582588075e-12,0.06749727893790501,75.22691425936378,5.39287104317433,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-96BMHR-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,435.8,1.998108,,,48.0,16.15,35.49,15.12,30.44,0.007848899999999999,-0.08592129000000001,44.91,1.2509324384021059,16.164490572460522,7.488594582588075e-12,0.06749727893790501,75.22691425936378,5.39287104317433,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-96BMHR-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,435.8,1.998108,,,48.0,16.15,35.49,15.12,30.44,0.007848899999999999,-0.08592129000000001,44.91,1.2509324384021059,16.164490572460522,7.488594582588075e-12,0.06749727893790501,75.22691425936378,5.39287104317433,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN460N-96BMHR-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,460.0,435.8,1.998108,,,48.0,16.15,35.49,15.12,30.44,0.007848899999999999,-0.08592129000000001,44.91,1.2509324384021059,16.164490572460522,7.488594582588075e-12,0.06749727893790501,75.22691425936378,5.39287104317433,-0.2891,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,465.0,438.1,2.16,,,60.0,13.79,42.65,13.08,35.56,0.005971069999999999,-0.1096105,43.93,1.534172399092566,13.797610246525863,1.1538889256852332e-11,0.175124122430257,317.3302802441112,4.1495310788459285,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,435.8,2.16,,,60.0,13.79,42.65,13.08,35.56,0.00558495,-0.10943989999999999,45.38,1.5351799819927827,13.797577674307714,1.1751713017808258e-11,0.1749517819400793,318.3806784317664,4.506938862734148,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,435.8,2.16,,,60.0,13.79,42.65,13.08,35.56,0.00558495,-0.10943989999999999,45.38,1.5351799819927827,13.797577674307714,1.1751713017808258e-11,0.1749517819400793,318.3806784317664,4.506938862734148,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,435.8,2.16,,,60.0,13.79,42.65,13.08,35.56,0.00558495,-0.10943989999999999,45.38,1.5351799819927827,13.797577674307714,1.1751713017808258e-11,0.1749517819400793,318.3806784317664,4.506938862734148,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,465.0,433.0,2.19,,,72.0,11.75,50.0,11.13,41.8,0.0059455,-0.1401,45.73,1.866461336782094,11.75000615562789,2.7281357218389692e-11,0.21625928509074893,412805.86231370433,3.5939336907421433,-0.3515,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,432.3,2.19,,,72.0,11.74,50.6,11.08,42.0,0.00552954,-0.1509398,44.98,1.9431483768657867,11.74793171929745,5.695255337048604e-11,0.23870489418031338,353.3150176123798,3.3224902459760317,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,465.0,431.7,2.39,,,78.0,11.22,52.5,10.64,43.7,0.00637296,-0.14889000000000002,46.17,1.9614425456698648,11.220009163855552,2.6647364982422522e-11,0.2570485887648649,314727.04616750905,2.45008025713691,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,442.4,2.163672,,,60.0,13.68,42.25,12.99,35.81,0.0069084,-0.1008085,44.9,1.4230065910543275,13.688292876481196,1.7223857205012902e-12,0.14274012435207806,235.46533063670023,-4.08179798381507,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,442.4,2.163672,,,60.0,13.68,42.25,12.99,35.81,0.0069084,-0.1008085,44.9,1.4230065910543275,13.688292876481196,1.7223857205012902e-12,0.14274012435207806,235.46533063670023,-4.08179798381507,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,442.4,2.163672,,,60.0,13.68,42.25,12.99,35.81,0.0069084,-0.1008085,44.9,1.4230065910543275,13.688292876481196,1.7223857205012902e-12,0.14274012435207806,235.46533063670023,-4.08179798381507,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,442.4,2.163672,,,60.0,13.68,42.25,12.99,35.81,0.0069084,-0.1008085,44.9,1.4230065910543275,13.688292876481196,1.7223857205012902e-12,0.14274012435207806,235.46533063670023,-4.08179798381507,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,442.4,2.163672,,,60.0,13.68,42.25,12.99,35.81,0.0069084,-0.1008085,44.9,1.4230065910543275,13.688292876481196,1.7223857205012902e-12,0.14274012435207806,235.46533063670023,-4.08179798381507,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,433.8,2.16,,,60.0,13.68,42.25,12.99,35.81,0.00549936,-0.117117,45.75,1.5667256683757547,13.684533681990617,2.6350032844043892e-11,0.11747181356740202,354.4612018072717,3.317818471704015,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,433.8,2.16,,,60.0,13.68,42.25,12.99,35.81,0.00549936,-0.117117,45.75,1.5667256683757547,13.684533681990617,2.6350032844043892e-11,0.11747181356740202,354.4612018072717,3.317818471704015,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN465N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,465.0,433.8,2.16,,,60.0,13.68,42.25,12.99,35.81,0.00549936,-0.117117,45.75,1.5667256683757547,13.684533681990617,2.6350032844043892e-11,0.11747181356740202,354.4612018072717,3.317818471704015,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,470.0,443.0,2.16,,,60.0,13.86,42.81,13.17,35.69,0.00600138,-0.11002170000000001,43.93,1.5385704842222139,13.865924471691553,1.1340361615698017e-11,0.1752810489749324,410.0610963140362,3.951328019915431,-0.3253,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,440.6,2.16,,,60.0,13.86,42.81,13.17,35.69,0.0056133,-0.10985046000000001,45.38,1.539580696511595,13.86589333513226,1.1549657234568775e-11,0.17510952075943775,411.8240625712548,4.30822819674158,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,440.6,2.16,,,60.0,13.86,42.81,13.17,35.69,0.0056133,-0.10985046000000001,45.38,1.539580696511595,13.86589333513226,1.1549657234568775e-11,0.17510952075943775,411.8240625712548,4.30822819674158,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,440.6,2.16,,,60.0,13.86,42.81,13.17,35.69,0.0056133,-0.10985046000000001,45.38,1.539580696511595,13.86589333513226,1.1549657234568775e-11,0.17510952075943775,411.8240625712548,4.30822819674158,-0.3285,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,437.1,2.19,,,72.0,11.81,50.8,11.14,42.2,0.0055625100000000005,-0.15153640000000002,44.98,1.9334945417257001,11.810006702407893,4.58918151915538e-11,0.23800737699595714,419391.08884373883,1.449971124885525,-0.3729,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,470.0,436.4,2.39,,,78.0,11.29,52.7,10.71,43.9,0.00641272,-0.1494572,46.17,1.9800650511596065,11.294436937947335,3.096034783055079e-11,0.25084930893922586,638.2980311888712,3.675247568479154,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,447.2,2.163672,,,60.0,13.73,42.51,13.05,36.02,0.00693365,-0.10142886,44.9,1.430959920930436,13.737628106456002,1.702032711591781e-12,0.14406177617450533,259.30002418314194,-4.210614421963857,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,447.2,2.163672,,,60.0,13.73,42.51,13.05,36.02,0.00693365,-0.10142886,44.9,1.430959920930436,13.737628106456002,1.702032711591781e-12,0.14406177617450533,259.30002418314194,-4.210614421963857,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,447.2,2.163672,,,60.0,13.73,42.51,13.05,36.02,0.00693365,-0.10142886,44.9,1.430959920930436,13.737628106456002,1.702032711591781e-12,0.14406177617450533,259.30002418314194,-4.210614421963857,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,447.2,2.163672,,,60.0,13.73,42.51,13.05,36.02,0.00693365,-0.10142886,44.9,1.430959920930436,13.737628106456002,1.702032711591781e-12,0.14406177617450533,259.30002418314194,-4.210614421963857,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,447.2,2.163672,,,60.0,13.73,42.51,13.05,36.02,0.00693365,-0.10142886,44.9,1.430959920930436,13.737628106456002,1.702032711591781e-12,0.14406177617450533,259.30002418314194,-4.210614421963857,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,438.6,2.16,,,60.0,13.73,42.51,13.05,36.02,0.00551946,-0.11783771999999999,45.75,1.5753943813913194,13.733966430093812,2.6039593162062036e-11,0.11879502186158052,411.2150298845469,3.1839948421855415,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,438.6,2.16,,,60.0,13.73,42.51,13.05,36.02,0.00551946,-0.11783771999999999,45.75,1.5753943813913194,13.733966430093812,2.6039593162062036e-11,0.11879502186158052,411.2150298845469,3.1839948421855415,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN470N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,470.0,438.6,2.16,,,60.0,13.73,42.51,13.05,36.02,0.00551946,-0.11783771999999999,45.75,1.5753943813913194,13.733966430093812,2.6039593162062036e-11,0.11879502186158052,411.2150298845469,3.1839948421855415,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,475.0,441.2,2.39,,,78.0,11.35,52.9,10.77,44.1,0.006446800000000001,-0.15002440000000003,46.17,1.9880792540166956,11.354228330080776,3.134203989456728e-11,0.24693128304931083,662.8314425190808,3.732796158864903,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,452.1,2.163672,,,60.0,13.78,42.78,13.11,36.24,0.0069589000000000005,-0.10207308000000001,44.9,1.4392774671429414,13.786948386191627,1.6831511292624417e-12,0.14527354155497835,288.1056621258178,-4.333283871259548,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,452.1,2.163672,,,60.0,13.78,42.78,13.11,36.24,0.0069589000000000005,-0.10207308000000001,44.9,1.4392774671429414,13.786948386191627,1.6831511292624417e-12,0.14527354155497835,288.1056621258178,-4.333283871259548,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,452.1,2.163672,,,60.0,13.78,42.78,13.11,36.24,0.0069589000000000005,-0.10207308000000001,44.9,1.4392774671429414,13.786948386191627,1.6831511292624417e-12,0.14527354155497835,288.1056621258178,-4.333283871259548,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,452.1,2.163672,,,60.0,13.78,42.78,13.11,36.24,0.0069589000000000005,-0.10207308000000001,44.9,1.4392774671429414,13.786948386191627,1.6831511292624417e-12,0.14527354155497835,288.1056621258178,-4.333283871259548,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,452.1,2.163672,,,60.0,13.78,42.78,13.11,36.24,0.0069589000000000005,-0.10207308000000001,44.9,1.4392774671429414,13.786948386191627,1.6831511292624417e-12,0.14527354155497835,288.1056621258178,-4.333283871259548,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,443.4,2.16,,,60.0,13.78,42.78,13.11,36.24,0.00553956,-0.11858616000000001,45.75,1.5844671169806135,13.78338608796811,2.5751571005224955e-11,0.12000063740393498,488.35376501378306,3.0565663518482156,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,443.4,2.16,,,60.0,13.78,42.78,13.11,36.24,0.00553956,-0.11858616000000001,45.75,1.5844671169806135,13.78338608796811,2.5751571005224955e-11,0.12000063740393498,488.35376501378306,3.0565663518482156,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN475N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,475.0,443.4,2.16,,,60.0,13.78,42.78,13.11,36.24,0.00553956,-0.11858616000000001,45.75,1.5844671169806135,13.78338608796811,2.5751571005224955e-11,0.12000063740393498,488.35376501378306,3.0565663518482156,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,480.0,446.0,2.39,,,78.0,11.42,53.1,10.84,44.3,0.00648656,-0.15059160000000002,46.17,1.9865867434069922,11.420008158692982,2.8137725523587622e-11,0.2446106543581712,342393.4881201623,2.755883110193001,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,456.9,2.163672,,,60.0,13.83,43.05,13.16,36.49,0.006984150000000001,-0.1027173,44.9,1.4486320432370692,13.83677289143925,1.6989505659698218e-12,0.14384765302670557,293.7317187331941,-4.2880859824691795,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,456.9,2.163672,,,60.0,13.83,43.05,13.16,36.49,0.006984150000000001,-0.1027173,44.9,1.4486320432370692,13.83677289143925,1.6989505659698218e-12,0.14384765302670557,293.7317187331941,-4.2880859824691795,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,456.9,2.163672,,,60.0,13.83,43.05,13.16,36.49,0.006984150000000001,-0.1027173,44.9,1.4486320432370692,13.83677289143925,1.6989505659698218e-12,0.14384765302670557,293.7317187331941,-4.2880859824691795,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,456.9,2.163672,,,60.0,13.83,43.05,13.16,36.49,0.006984150000000001,-0.1027173,44.9,1.4486320432370692,13.83677289143925,1.6989505659698218e-12,0.14384765302670557,293.7317187331941,-4.2880859824691795,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,456.9,2.163672,,,60.0,13.83,43.05,13.16,36.49,0.006984150000000001,-0.1027173,44.9,1.4486320432370692,13.83677289143925,1.6989505659698218e-12,0.14384765302670557,293.7317187331941,-4.2880859824691795,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,448.2,2.16,,,60.0,13.83,43.05,13.16,36.49,0.00555966,-0.1193346,45.75,1.5947928165974912,13.83325565185331,2.5992104450448213e-11,0.1184930745993229,503.35825765301803,3.1033239798549777,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,448.2,2.16,,,60.0,13.83,43.05,13.16,36.49,0.00555966,-0.1193346,45.75,1.5947928165974912,13.83325565185331,2.5992104450448213e-11,0.1184930745993229,503.35825765301803,3.1033239798549777,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN480N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,480.0,448.2,2.16,,,60.0,13.83,43.05,13.16,36.49,0.00555966,-0.1193346,45.75,1.5947928165974912,13.83325565185331,2.5992104450448213e-11,0.1184930745993229,503.35825765301803,3.1033239798549777,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,485.0,454.5,2.37,,,66.0,13.71,44.8,12.84,37.8,0.00611466,-0.11477759999999998,45.18,1.6325383950526315,13.725720905368595,1.6151903413638115e-11,0.14403878166263098,125.61437504322035,7.472010772035132,-0.3251,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,453.7,2.37,,,66.0,13.71,44.8,12.84,37.8,0.005607389999999999,-0.1145984,45.64,1.6291681697977256,13.725843919458201,1.525916431492758e-11,0.1446328627800785,125.15315787003526,7.196118410545732,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,453.7,2.37,,,66.0,13.71,44.8,12.84,37.8,0.005607389999999999,-0.1145984,45.64,1.6291681697977256,13.725843919458201,1.525916431492758e-11,0.1446328627800785,125.15315787003526,7.196118410545732,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,453.7,2.37,,,66.0,13.71,44.8,12.84,37.8,0.005607389999999999,-0.1145984,45.64,1.6291681697977256,13.725843919458201,1.525916431492758e-11,0.1446328627800785,125.15315787003526,7.196118410545732,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,485.0,450.8,2.39,,,78.0,11.48,53.3,10.9,44.5,0.006520640000000001,-0.1511588,46.17,1.9949467720192164,11.48000979753899,2.8620037304245853e-11,0.24071181197146702,282049.9908883596,2.853886654636845,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,461.8,2.163672,,,60.0,13.88,43.3,13.21,36.72,0.007009400000000001,-0.1033138,44.9,1.4572569781954299,13.886608720673332,1.7127892007326833e-12,0.14262703408403213,299.5531836367379,-4.252649243759372,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,461.8,2.163672,,,60.0,13.88,43.3,13.21,36.72,0.007009400000000001,-0.1033138,44.9,1.4572569781954299,13.886608720673332,1.7127892007326833e-12,0.14262703408403213,299.5531836367379,-4.252649243759372,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,461.8,2.163672,,,60.0,13.88,43.3,13.21,36.72,0.007009400000000001,-0.1033138,44.9,1.4572569781954299,13.886608720673332,1.7127892007326833e-12,0.14262703408403213,299.5531836367379,-4.252649243759372,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,461.8,2.163672,,,60.0,13.88,43.3,13.21,36.72,0.007009400000000001,-0.1033138,44.9,1.4572569781954299,13.886608720673332,1.7127892007326833e-12,0.14262703408403213,299.5531836367379,-4.252649243759372,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,461.8,2.163672,,,60.0,13.88,43.3,13.21,36.72,0.007009400000000001,-0.1033138,44.9,1.4572569781954299,13.886608720673332,1.7127892007326833e-12,0.14262703408403213,299.5531836367379,-4.252649243759372,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,453.0,2.16,,,60.0,13.88,43.3,13.21,36.72,0.0055797600000000004,-0.1200276,45.75,1.6043093620712332,13.883131516433691,2.6202818258511075e-11,0.11720662923758791,519.5016732623751,3.139971710051882,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,453.0,2.16,,,60.0,13.88,43.3,13.21,36.72,0.0055797600000000004,-0.1200276,45.75,1.6043093620712332,13.883131516433691,2.6202818258511075e-11,0.11720662923758791,519.5016732623751,3.139971710051882,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN485N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,485.0,453.0,2.16,,,60.0,13.88,43.3,13.21,36.72,0.0055797600000000004,-0.1200276,45.75,1.6043093620712332,13.883131516433691,2.6202818258511075e-11,0.11720662923758791,519.5016732623751,3.139971710051882,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,490.0,459.3,2.37,,,66.0,13.78,45.0,12.9,38.0,0.00614588,-0.11528999999999999,45.18,1.6408479055399954,13.79582941357954,1.650448743060875e-11,0.14112366420427866,122.85256740057974,7.61858181743179,-0.3251,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,458.5,2.37,,,66.0,13.78,45.0,12.9,38.0,0.00563602,-0.11511000000000002,45.64,1.6374592276118434,13.795953326685238,1.5592475264733473e-11,0.14171862689010808,122.41225428010947,7.3424137037368915,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,458.5,2.37,,,66.0,13.78,45.0,12.9,38.0,0.00563602,-0.11511000000000002,45.64,1.6374592276118434,13.795953326685238,1.5592475264733473e-11,0.14171862689010808,122.41225428010947,7.3424137037368915,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,458.5,2.37,,,66.0,13.78,45.0,12.9,38.0,0.00563602,-0.11511000000000002,45.64,1.6374592276118434,13.795953326685238,1.5592475264733473e-11,0.14171862689010808,122.41225428010947,7.3424137037368915,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,490.0,455.5,2.39,,,78.0,11.55,53.5,10.97,44.7,0.006560400000000001,-0.15172600000000003,46.17,2.0033322294743536,11.550007336814256,2.91422552330413e-11,0.23664344129472226,372540.8503955477,2.9540195908593123,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,466.6,2.163672,,,60.0,13.94,43.54,13.27,36.94,0.0070397,-0.10388644000000001,44.9,1.4654931998677456,13.94642846854131,1.7261219088127352e-12,0.1414137430434993,306.65275365252285,-4.225887082697506,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,466.6,2.163672,,,60.0,13.94,43.54,13.27,36.94,0.0070397,-0.10388644000000001,44.9,1.4654931998677456,13.94642846854131,1.7261219088127352e-12,0.1414137430434993,306.65275365252285,-4.225887082697506,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,466.6,2.163672,,,60.0,13.94,43.54,13.27,36.94,0.0070397,-0.10388644000000001,44.9,1.4654931998677456,13.94642846854131,1.7261219088127352e-12,0.1414137430434993,306.65275365252285,-4.225887082697506,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,466.6,2.163672,,,60.0,13.94,43.54,13.27,36.94,0.0070397,-0.10388644000000001,44.9,1.4654931998677456,13.94642846854131,1.7261219088127352e-12,0.1414137430434993,306.65275365252285,-4.225887082697506,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,466.6,2.163672,,,60.0,13.94,43.54,13.27,36.94,0.0070397,-0.10388644000000001,44.9,1.4654931998677456,13.94642846854131,1.7261219088127352e-12,0.1414137430434993,306.65275365252285,-4.225887082697506,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,457.8,2.16,,,60.0,13.94,43.54,13.27,36.94,0.0056038799999999995,-0.12069288,45.75,1.6133924158553017,13.942991158777147,2.640590808501641e-11,0.11595586962338705,540.4007205684778,3.1676257077377117,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,457.8,2.16,,,60.0,13.94,43.54,13.27,36.94,0.0056038799999999995,-0.12069288,45.75,1.6133924158553017,13.942991158777147,2.640590808501641e-11,0.11595586962338705,540.4007205684778,3.1676257077377117,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN490N-120MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,490.0,457.8,2.16,,,60.0,13.94,43.54,13.27,36.94,0.0056038799999999995,-0.12069288,45.75,1.6133924158553017,13.942991158777147,2.640590808501641e-11,0.11595586962338705,540.4007205684778,3.1676257077377117,-0.3446,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,495.0,464.1,2.37,,,66.0,13.85,45.2,12.96,38.2,0.0061771000000000005,-0.1158024,45.18,1.649158369692323,13.865923058548558,1.6861794453466178e-11,0.13823536911598194,120.23819801022314,7.763992678072171,-0.3251,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,463.3,2.37,,,66.0,13.85,45.2,12.96,38.2,0.00566465,-0.11562160000000002,45.64,1.6457512927401259,13.866047880545002,1.59302708904646e-11,0.13883119619798956,119.81719743607698,7.487559056837524,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,463.3,2.37,,,66.0,13.85,45.2,12.96,38.2,0.00566465,-0.11562160000000002,45.64,1.6457512927401259,13.866047880545002,1.59302708904646e-11,0.13883119619798956,119.81719743607698,7.487559056837524,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,463.3,2.37,,,66.0,13.85,45.2,12.96,38.2,0.00566465,-0.11562160000000002,45.64,1.6457512927401259,13.866047880545002,1.59302708904646e-11,0.13883119619798956,119.81719743607698,7.487559056837524,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495-156BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,495.0,460.3,2.39,,,78.0,11.62,53.7,11.03,44.9,0.00660016,-0.15229320000000002,46.17,2.0110097821481214,11.620006779080637,2.939236633625077e-11,0.23280557226998966,399056.18369367317,2.9749158107249514,-0.3471,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,471.5,2.163672,,,60.0,13.99,43.79,13.32,37.17,0.00706495,-0.10448294000000001,44.9,1.4741167257127903,13.996270005809082,1.7399157255341396e-12,0.14021295832092798,312.8512712957278,-4.191422369534352,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,471.5,2.163672,,,60.0,13.99,43.79,13.32,37.17,0.00706495,-0.10448294000000001,44.9,1.4741167257127903,13.996270005809082,1.7399157255341396e-12,0.14021295832092798,312.8512712957278,-4.191422369534352,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,471.5,2.163672,,,60.0,13.99,43.79,13.32,37.17,0.00706495,-0.10448294000000001,44.9,1.4741167257127903,13.996270005809082,1.7399157255341396e-12,0.14021295832092798,312.8512712957278,-4.191422369534352,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,471.5,2.163672,,,60.0,13.99,43.79,13.32,37.17,0.00706495,-0.10448294000000001,44.9,1.4741167257127903,13.996270005809082,1.7399157255341396e-12,0.14021295832092798,312.8512712957278,-4.191422369534352,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN495N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,495.0,471.5,2.163672,,,60.0,13.99,43.79,13.32,37.17,0.00706495,-0.10448294000000001,44.9,1.4741167257127903,13.996270005809082,1.7399157255341396e-12,0.14021295832092798,312.8512712957278,-4.191422369534352,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,500.0,469.0,2.37,,,66.0,13.93,45.4,13.03,38.4,0.00621278,-0.1163148,45.18,1.6574293037053909,13.945980079966661,1.7225692685697436e-11,0.13528264543009275,117.92727320425867,7.902679557068289,-0.3251,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,468.1,2.37,,,66.0,13.93,45.4,13.03,38.4,0.00569737,-0.11613320000000002,45.64,1.6540039630894936,13.94610574950981,1.6274294040399226e-11,0.13587884057409966,117.52276739043431,7.625991343935967,-0.3268,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,468.1,2.37,,,66.0,13.93,45.4,13.03,38.4,0.00569737,-0.11613320000000002,45.64,1.6540039630894936,13.94610574950981,1.6274294040399226e-11,0.13587884057409966,117.52276739043431,7.625991343935967,-0.3268,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,468.1,2.37,,,66.0,13.93,45.4,13.03,38.4,0.00569737,-0.11613320000000002,45.64,1.6540039630894936,13.94610574950981,1.6274294040399226e-11,0.13587884057409966,117.52276739043431,7.625991343935967,-0.3268,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500N-120BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,476.4,2.163672,,,60.0,14.05,44.01,13.37,37.4,0.007095250000000001,-0.10500786,44.9,1.482665529076441,14.056577143486953,1.78657296337757e-12,0.13662047663367993,291.8467116046632,-4.010797294221069,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500N-120BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,476.4,2.163672,,,60.0,14.05,44.01,13.37,37.4,0.007095250000000001,-0.10500786,44.9,1.482665529076441,14.056577143486953,1.78657296337757e-12,0.13662047663367993,291.8467116046632,-4.010797294221069,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500N-120BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,476.4,2.163672,,,60.0,14.05,44.01,13.37,37.4,0.007095250000000001,-0.10500786,44.9,1.482665529076441,14.056577143486953,1.78657296337757e-12,0.13662047663367993,291.8467116046632,-4.010797294221069,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500N-120BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,476.4,2.163672,,,60.0,14.05,44.01,13.37,37.4,0.007095250000000001,-0.10500786,44.9,1.482665529076441,14.056577143486953,1.78657296337757e-12,0.13662047663367993,291.8467116046632,-4.010797294221069,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN500N-120BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,500.0,476.4,2.163672,,,60.0,14.05,44.01,13.37,37.4,0.007095250000000001,-0.10500786,44.9,1.482665529076441,14.056577143486953,1.78657296337757e-12,0.13662047663367993,291.8467116046632,-4.010797294221069,-0.2605,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN505-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,505.0,473.8,2.37,,,66.0,14.0,45.6,13.09,38.6,0.006244,-0.11682719999999999,45.18,1.6657412866984855,14.01604522301389,1.759243045549242e-11,0.13244959254434785,115.56675143568243,8.045786748736045,-0.3251,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN505-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,505.0,472.9,2.37,,,66.0,14.0,45.6,13.09,38.6,0.005726,-0.11664480000000002,45.64,1.662297587668387,14.016171790557006,1.662102878496597e-11,0.13304663090258712,115.17913410497187,7.768843235331727,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN505-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,505.0,472.9,2.37,,,66.0,14.0,45.6,13.09,38.6,0.005726,-0.11664480000000002,45.64,1.662297587668387,14.016171790557006,1.662102878496597e-11,0.13304663090258712,115.17913410497187,7.768843235331727,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN505-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,505.0,472.9,2.37,,,66.0,14.0,45.6,13.09,38.6,0.005726,-0.11664480000000002,45.64,1.662297587668387,14.016171790557006,1.662102878496597e-11,0.13304663090258712,115.17913410497187,7.768843235331727,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN510-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,510.0,478.6,2.37,,,66.0,14.09,45.76,13.17,38.77,0.00628414,-0.11723712,45.18,1.6725942058928167,14.106015784160384,1.799201683945657e-11,0.129020686316506,113.50686647671732,8.188616407275589,-0.3251,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN510-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,510.0,477.7,2.37,,,66.0,14.09,45.76,13.17,38.77,0.00576281,-0.11705408000000002,45.64,1.6691352060488212,14.10614303944275,1.699881889378313e-11,0.12961715419879202,113.13270421944837,7.911417554670195,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN510-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,510.0,477.7,2.37,,,66.0,14.09,45.76,13.17,38.77,0.00576281,-0.11705408000000002,45.64,1.6691352060488212,14.10614303944275,1.699881889378313e-11,0.12961715419879202,113.13270421944837,7.911417554670195,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN510-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,510.0,477.7,2.37,,,66.0,14.09,45.76,13.17,38.77,0.00576281,-0.11705408000000002,45.64,1.6691352060488212,14.10614303944275,1.699881889378313e-11,0.12961715419879202,113.13270421944837,7.911417554670195,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,482.5,2.37,,,66.0,14.16,45.92,13.26,38.84,0.00579144,-0.11746336000000003,45.64,1.6720310162528926,14.175596107613936,1.6317184811938066e-11,0.13532729828760903,122.8662039599694,7.500768528750928,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,482.5,2.37,,,66.0,14.16,45.92,13.26,38.84,0.00579144,-0.11746336000000003,45.64,1.6720310162528926,14.175596107613936,1.6317184811938066e-11,0.13532729828760903,122.8662039599694,7.500768528750928,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,482.5,2.37,,,66.0,14.16,45.92,13.26,38.84,0.00579144,-0.11746336000000003,45.64,1.6720310162528926,14.175596107613936,1.6317184811938066e-11,0.13532729828760903,122.8662039599694,7.500768528750928,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,474.8,2.54,,,72.0,13.45,49.0,12.56,41.02,0.00811035,-0.142884,46.45,1.9341314654341581,13.464992086808058,1.3051701011115164e-10,0.1627342228704174,145.99537535845786,11.667259313426717,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,474.8,2.54,,,72.0,13.45,49.0,12.56,41.02,0.00811035,-0.142884,46.45,1.9341314654341581,13.464992086808058,1.3051701011115164e-10,0.1627342228704174,145.99537535845786,11.667259313426717,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,474.8,2.54,,,72.0,13.45,49.0,12.56,41.02,0.00811035,-0.142884,46.45,1.9341314654341581,13.464992086808058,1.3051701011115164e-10,0.1627342228704174,145.99537535845786,11.667259313426717,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,487.2,2.37,,,66.0,13.63,46.94,12.99,39.65,0.0068286300000000005,-0.11181108,45.01,1.6289864664540257,13.634446012564865,4.1420547916404465e-12,0.16179596183539358,496.01276082554057,3.3598495033927906,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,487.2,2.37,,,66.0,13.63,46.94,12.99,39.65,0.0068286300000000005,-0.11181108,45.01,1.6289864664540257,13.634446012564865,4.1420547916404465e-12,0.16179596183539358,496.01276082554057,3.3598495033927906,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,487.2,2.37,,,66.0,13.63,46.94,12.99,39.65,0.0068286300000000005,-0.11181108,45.01,1.6289864664540257,13.634446012564865,4.1420547916404465e-12,0.16179596183539358,496.01276082554057,3.3598495033927906,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,487.2,2.37,,,66.0,13.63,46.94,12.99,39.65,0.0068286300000000005,-0.11181108,45.01,1.6289864664540257,13.634446012564865,4.1420547916404465e-12,0.16179596183539358,496.01276082554057,3.3598495033927906,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,487.2,2.37,,,66.0,13.63,46.94,12.99,39.65,0.0068286300000000005,-0.11181108,45.01,1.6289864664540257,13.634446012564865,4.1420547916404465e-12,0.16179596183539358,496.01276082554057,3.3598495033927906,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,480.8,2.37,,,66.0,13.63,46.94,12.99,39.65,0.00573823,-0.13204222,45.9,1.7285678719645028,13.632371194208966,2.184308952489351e-11,0.14443617394166283,830.2419610324825,0.2571582007708403,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,480.8,2.37,,,66.0,13.63,46.94,12.99,39.65,0.00573823,-0.13204222,45.9,1.7285678719645028,13.632371194208966,2.184308952489351e-11,0.14443617394166283,830.2419610324825,0.2571582007708403,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN515N-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,515.0,480.8,2.37,,,66.0,13.63,46.94,12.99,39.65,0.00573823,-0.13204222,45.9,1.7285678719645028,13.632371194208966,2.184308952489351e-11,0.14443617394166283,830.2419610324825,0.2571582007708403,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,487.3,2.37,,,66.0,14.23,46.08,13.34,38.99,0.00582007,-0.11787264000000001,45.64,1.6772812871801683,14.244794576383983,1.626416897338926e-11,0.13400648537334695,128.89265921340117,7.424511891638533,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,487.3,2.37,,,66.0,14.23,46.08,13.34,38.99,0.00582007,-0.11787264000000001,45.64,1.6772812871801683,14.244794576383983,1.626416897338926e-11,0.13400648537334695,128.89265921340117,7.424511891638533,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,487.3,2.37,,,66.0,14.23,46.08,13.34,38.99,0.00582007,-0.11787264000000001,45.64,1.6772812871801683,14.244794576383983,1.626416897338926e-11,0.13400648537334695,128.89265921340117,7.424511891638533,-0.3268,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,520.0,486.5,2.58,,,72.0,13.53,49.11,12.65,41.11,0.00585849,-0.12454296,45.83,1.7726324808528742,13.549858940911857,1.223924478107683e-11,0.19137501002098659,130.3847926613661,6.294962007778176,-0.3213,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,520.0,485.2,2.58,,,72.0,13.53,49.11,12.65,41.11,0.005249640000000001,-0.12729311999999998,45.99,1.7862452261158035,13.549352745393223,1.5121435435918955e-11,0.1889508606735931,132.10038688478923,5.849648691483594,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,479.6,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00815859,-0.14320476000000001,46.45,1.9371954492790402,13.544226537884274,1.2930325934293816e-10,0.1625148706612426,154.5580702940482,11.52469663611258,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,479.6,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00815859,-0.14320476000000001,46.45,1.9371954492790402,13.544226537884274,1.2930325934293816e-10,0.1625148706612426,154.5580702940482,11.52469663611258,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,479.6,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00815859,-0.14320476000000001,46.45,1.9371954492790402,13.544226537884274,1.2930325934293816e-10,0.1625148706612426,154.5580702940482,11.52469663611258,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,480.3,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00754974,-0.14394141000000002,45.81,1.9386099909630359,13.544182632588242,1.317219384599984e-10,0.16227088029557507,154.8037744804103,11.17136141789664,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,480.3,2.54,,,72.0,13.53,49.11,12.65,41.11,0.00754974,-0.14394141000000002,45.81,1.9386099909630359,13.544182632588242,1.317219384599984e-10,0.16227088029557507,154.8037744804103,11.17136141789664,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,492.0,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00685368,-0.11240657999999999,45.01,1.6378917774659478,13.6843039100898,4.1747646445638935e-12,0.16043989845303092,509.9590305194313,3.395087945467894,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,492.0,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00685368,-0.11240657999999999,45.01,1.6378917774659478,13.6843039100898,4.1747646445638935e-12,0.16043989845303092,509.9590305194313,3.395087945467894,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,492.0,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00685368,-0.11240657999999999,45.01,1.6378917774659478,13.6843039100898,4.1747646445638935e-12,0.16043989845303092,509.9590305194313,3.395087945467894,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,492.0,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00685368,-0.11240657999999999,45.01,1.6378917774659478,13.6843039100898,4.1747646445638935e-12,0.16043989845303092,509.9590305194313,3.395087945467894,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,520.0,492.4,2.3746,,,66.0,13.68,47.19,13.04,39.88,0.00545832,-0.11108525999999999,44.6,1.6224766880577857,13.684655597870686,3.1737491605914716e-12,0.16315196421275766,479.4054250730103,2.439264098792146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,520.0,492.4,2.3746,,,66.0,13.68,47.19,13.04,39.88,0.00545832,-0.11108525999999999,44.6,1.6224766880577857,13.684655597870686,3.1737491605914716e-12,0.16315196421275766,479.4054250730103,2.439264098792146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,520.0,492.4,2.3746,,,66.0,13.68,47.19,13.04,39.88,0.00545832,-0.11108525999999999,44.6,1.6224766880577857,13.684655597870686,3.1737491605914716e-12,0.16315196421275766,479.4054250730103,2.439264098792146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,520.0,492.4,2.3746,,,66.0,13.68,47.19,13.04,39.88,0.00545832,-0.11108525999999999,44.6,1.6224766880577857,13.684655597870686,3.1737491605914716e-12,0.16315196421275766,479.4054250730103,2.439264098792146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,492.0,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00685368,-0.11240657999999999,45.01,1.6378917774659478,13.6843039100898,4.1747646445638935e-12,0.16043989845303092,509.9590305194313,3.395087945467894,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,485.6,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00575928,-0.13274547,45.9,1.738036187778702,13.682253035216467,2.2016856257613617e-11,0.1430438141542511,868.5347421667931,0.29120249476997706,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,485.6,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00575928,-0.13274547,45.9,1.738036187778702,13.682253035216467,2.2016856257613617e-11,0.1430438141542511,868.5347421667931,0.29120249476997706,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN520N-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,520.0,485.6,2.37,,,66.0,13.68,47.19,13.04,39.88,0.00575928,-0.13274547,45.9,1.738036187778702,13.682253035216467,2.2016856257613617e-11,0.1430438141542511,868.5347421667931,0.29120249476997706,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,525.0,491.3,2.58,,,72.0,13.63,49.22,12.74,41.22,0.00590179,-0.12482192,45.83,1.7772233225019543,13.650089697267882,1.2445008478960506e-11,0.18876054758420616,128.0659552200614,6.377007279826844,-0.3213,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,525.0,490.0,2.58,,,72.0,13.63,49.22,12.74,41.22,0.00528844,-0.12757824,45.99,1.7908775851031977,13.64957866101264,1.5375992135370032e-11,0.18634526903765786,129.727258850436,5.931318971829241,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,484.3,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00821889,-0.14352552000000002,46.45,1.9422687083001726,13.644403668963108,1.3146481233308083e-10,0.16000943846972848,151.4148024389307,11.609015236482218,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,484.3,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00821889,-0.14352552000000002,46.45,1.9422687083001726,13.644403668963108,1.3146481233308083e-10,0.16000943846972848,151.4148024389307,11.609015236482218,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,484.3,2.54,,,72.0,13.63,49.22,12.74,41.22,0.00821889,-0.14352552000000002,46.45,1.9422687083001726,13.644403668963108,1.3146481233308083e-10,0.16000943846972848,151.4148024389307,11.609015236482218,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,485.1,2.54,,,72.0,13.63,49.22,12.74,41.22,0.007605540000000001,-0.14426382000000001,45.81,1.9436888824561083,13.644359293782069,1.3392635133192105e-10,0.15976611496647908,151.65176101908668,11.255516140253121,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,485.1,2.54,,,72.0,13.63,49.22,12.74,41.22,0.007605540000000001,-0.14426382000000001,45.81,1.9436888824561083,13.644359293782069,1.3392635133192105e-10,0.15976611496647908,151.65176101908668,11.255516140253121,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,496.9,2.37,,,66.0,13.74,47.41,13.09,40.11,0.006883739999999999,-0.11293062,45.01,1.6467828093940198,13.744690722183378,4.2830235398186516e-12,0.15661850051800194,458.7647956654214,3.5793609116726888,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,496.9,2.37,,,66.0,13.74,47.41,13.09,40.11,0.006883739999999999,-0.11293062,45.01,1.6467828093940198,13.744690722183378,4.2830235398186516e-12,0.15661850051800194,458.7647956654214,3.5793609116726888,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,496.9,2.37,,,66.0,13.74,47.41,13.09,40.11,0.006883739999999999,-0.11293062,45.01,1.6467828093940198,13.744690722183378,4.2830235398186516e-12,0.15661850051800194,458.7647956654214,3.5793609116726888,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,496.9,2.37,,,66.0,13.74,47.41,13.09,40.11,0.006883739999999999,-0.11293062,45.01,1.6467828093940198,13.744690722183378,4.2830235398186516e-12,0.15661850051800194,458.7647956654214,3.5793609116726888,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,525.0,497.2,2.3746,,,66.0,13.74,47.41,13.09,40.11,0.005482259999999999,-0.11160313999999999,44.6,1.6312707452067556,13.745044897880227,3.255961694375325e-12,0.1593396563636469,433.96852313160826,2.6219561317986146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,525.0,497.2,2.3746,,,66.0,13.74,47.41,13.09,40.11,0.005482259999999999,-0.11160313999999999,44.6,1.6312707452067556,13.745044897880227,3.255961694375325e-12,0.1593396563636469,433.96852313160826,2.6219561317986146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,525.0,497.2,2.3746,,,66.0,13.74,47.41,13.09,40.11,0.005482259999999999,-0.11160313999999999,44.6,1.6312707452067556,13.745044897880227,3.255961694375325e-12,0.1593396563636469,433.96852313160826,2.6219561317986146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,525.0,497.2,2.3746,,,66.0,13.74,47.41,13.09,40.11,0.005482259999999999,-0.11160313999999999,44.6,1.6312707452067556,13.745044897880227,3.255961694375325e-12,0.1593396563636469,433.96852313160826,2.6219561317986146,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,496.9,2.37,,,66.0,13.74,47.41,13.09,40.11,0.006883739999999999,-0.11293062,45.01,1.6467828093940198,13.744690722183378,4.2830235398186516e-12,0.15661850051800194,458.7647956654214,3.5793609116726888,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,490.4,2.37,,,66.0,13.74,47.41,13.09,40.11,0.0057845399999999995,-0.13336432999999998,45.9,1.7475751186524722,13.742624929163163,2.259562621137779e-11,0.13916109618669129,728.4286072207998,0.46942099175342994,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,490.4,2.37,,,66.0,13.74,47.41,13.09,40.11,0.0057845399999999995,-0.13336432999999998,45.9,1.7475751186524722,13.742624929163163,2.259562621137779e-11,0.13916109618669129,728.4286072207998,0.46942099175342994,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN525N-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,525.0,490.4,2.37,,,66.0,13.74,47.41,13.09,40.11,0.0057845399999999995,-0.13336432999999998,45.9,1.7475751186524722,13.742624929163163,2.259562621137779e-11,0.13916109618669129,728.4286072207998,0.46942099175342994,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,530.0,496.1,2.58,,,72.0,13.71,49.35,12.82,41.35,0.0059364299999999995,-0.1251516,45.83,1.7820204066377268,13.729683477058435,1.2543539706229144e-11,0.18630538996422752,129.7660416101942,6.393041617077923,-0.3213,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,530.0,494.8,2.58,,,72.0,13.71,49.35,12.82,41.35,0.0053194800000000006,-0.1279152,45.99,1.7957120096229235,13.729176401871037,1.5497655917310734e-11,0.18389795925719837,131.47623023993734,5.947188431981802,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,489.1,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00826713,-0.14390460000000002,46.45,1.9475216222840601,13.72404679998169,1.3250558831027894e-10,0.1576469044837296,153.86700938179297,11.625905643184089,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,489.1,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00826713,-0.14390460000000002,46.45,1.9475216222840601,13.72404679998169,1.3250558831027894e-10,0.1576469044837296,153.86700938179297,11.625905643184089,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,489.1,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00826713,-0.14390460000000002,46.45,1.9475216222840601,13.72404679998169,1.3250558831027894e-10,0.1576469044837296,153.86700938179297,11.625905643184089,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,489.8,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00765018,-0.14464485000000002,45.81,1.9489455457397764,13.724002869563483,1.349862968498977e-10,0.15740439416902527,154.11228937197748,11.27229504919357,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,489.8,2.54,,,72.0,13.71,49.35,12.82,41.35,0.00765018,-0.14464485000000002,45.81,1.9489455457397764,13.724002869563483,1.349862968498977e-10,0.15740439416902527,154.11228937197748,11.27229504919357,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,501.7,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0069138,-0.11345466000000001,45.01,1.6556760431673798,13.805052901374774,4.3931661873276295e-12,0.15282572239337128,417.38296843055474,3.7622507727984322,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,501.7,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0069138,-0.11345466000000001,45.01,1.6556760431673798,13.805052901374774,4.3931661873276295e-12,0.15282572239337128,417.38296843055474,3.7622507727984322,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,501.7,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0069138,-0.11345466000000001,45.01,1.6556760431673798,13.805052901374774,4.3931661873276295e-12,0.15282572239337128,417.38296843055474,3.7622507727984322,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,501.7,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0069138,-0.11345466000000001,45.01,1.6556760431673798,13.805052901374774,4.3931661873276295e-12,0.15282572239337128,417.38296843055474,3.7622507727984322,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,530.0,502.1,2.3746,,,66.0,13.8,47.63,13.14,40.34,0.0055062,-0.11212102000000002,44.6,1.640067164835775,13.805409626415496,3.3396158738984183e-12,0.15555587516803368,396.82427530439816,2.803307171507689,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,530.0,502.1,2.3746,,,66.0,13.8,47.63,13.14,40.34,0.0055062,-0.11212102000000002,44.6,1.640067164835775,13.805409626415496,3.3396158738984183e-12,0.15555587516803368,396.82427530439816,2.803307171507689,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,530.0,502.1,2.3746,,,66.0,13.8,47.63,13.14,40.34,0.0055062,-0.11212102000000002,44.6,1.640067164835775,13.805409626415496,3.3396158738984183e-12,0.15555587516803368,396.82427530439816,2.803307171507689,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,530.0,502.1,2.3746,,,66.0,13.8,47.63,13.14,40.34,0.0055062,-0.11212102000000002,44.6,1.640067164835775,13.805409626415496,3.3396158738984183e-12,0.15555587516803368,396.82427530439816,2.803307171507689,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,501.7,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0069138,-0.11345466000000001,45.01,1.6556760431673798,13.805052901374774,4.3931661873276295e-12,0.15282572239337128,417.38296843055474,3.7622507727984322,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,495.2,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0058098,-0.13398319,45.9,1.757116913014956,13.802971758111156,2.318472637858444e-11,0.13530731901646315,628.3287393053059,0.6463437392762692,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,495.2,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0058098,-0.13398319,45.9,1.757116913014956,13.802971758111156,2.318472637858444e-11,0.13530731901646315,628.3287393053059,0.6463437392762692,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN530N-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,530.0,495.2,2.37,,,66.0,13.8,47.63,13.14,40.34,0.0058098,-0.13398319,45.9,1.757116913014956,13.802971758111156,2.318472637858444e-11,0.13530731901646315,628.3287393053059,0.6463437392762692,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,535.0,500.9,2.58,,,72.0,13.78,49.5,12.9,41.5,0.00596674,-0.125532,45.83,1.7869854921234167,13.798632811253386,1.253562906567682e-11,0.18387078056339023,135.9826666442418,6.338669221918257,-0.3213,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,535.0,499.6,2.58,,,72.0,13.78,49.5,12.9,41.5,0.005346640000000001,-0.128304,45.99,1.8007095600737,13.798138659583726,1.5487373974578642e-11,0.18147222163167046,137.86505066155618,5.8928785199890985,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,493.8,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00830934,-0.144342,46.45,1.9529090116208534,13.793150522705783,1.3243506786458322e-10,0.15531269211096033,162.7470624622273,11.570871530791399,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,493.8,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00830934,-0.144342,46.45,1.9529090116208534,13.793150522705783,1.3243506786458322e-10,0.15531269211096033,162.7470624622273,11.570871530791399,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,493.8,2.54,,,72.0,13.78,49.5,12.9,41.5,0.00830934,-0.144342,46.45,1.9529090116208534,13.793150522705783,1.3243506786458322e-10,0.15531269211096033,162.7470624622273,11.570871530791399,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,494.6,2.54,,,72.0,13.78,49.5,12.9,41.5,0.007689240000000001,-0.1450845,45.81,1.9543346250201377,13.793107974901401,1.3491120589783018e-10,0.1550713601730775,163.02162658382755,11.2172071149785,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,494.6,2.54,,,72.0,13.78,49.5,12.9,41.5,0.007689240000000001,-0.1450845,45.81,1.9543346250201377,13.793107974901401,1.3491120589783018e-10,0.1550713601730775,163.02162658382755,11.2172071149785,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,506.6,2.37,,,66.0,13.86,47.85,13.19,40.57,0.00694386,-0.1139787,45.01,1.6645714540734928,13.865390859539175,4.505206433536318e-12,0.1490612398253961,383.23921693739794,3.9437729380144386,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,506.6,2.37,,,66.0,13.86,47.85,13.19,40.57,0.00694386,-0.1139787,45.01,1.6645714540734928,13.865390859539175,4.505206433536318e-12,0.1490612398253961,383.23921693739794,3.9437729380144386,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,506.6,2.37,,,66.0,13.86,47.85,13.19,40.57,0.00694386,-0.1139787,45.01,1.6645714540734928,13.865390859539175,4.505206433536318e-12,0.1490612398253961,383.23921693739794,3.9437729380144386,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,506.6,2.37,,,66.0,13.86,47.85,13.19,40.57,0.00694386,-0.1139787,45.01,1.6645714540734928,13.865390859539175,4.505206433536318e-12,0.1490612398253961,383.23921693739794,3.9437729380144386,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,535.0,506.9,2.3746,,,66.0,13.86,47.85,13.19,40.57,0.005530139999999999,-0.11263890000000001,44.6,1.6488659225380173,13.865750193867905,3.42472290738362e-12,0.1518002972481646,365.8923807296025,2.9833320613351573,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,535.0,506.9,2.3746,,,66.0,13.86,47.85,13.19,40.57,0.005530139999999999,-0.11263890000000001,44.6,1.6488659225380173,13.865750193867905,3.42472290738362e-12,0.1518002972481646,365.8923807296025,2.9833320613351573,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,535.0,506.9,2.3746,,,66.0,13.86,47.85,13.19,40.57,0.005530139999999999,-0.11263890000000001,44.6,1.6488659225380173,13.865750193867905,3.42472290738362e-12,0.1518002972481646,365.8923807296025,2.9833320613351573,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,535.0,506.9,2.3746,,,66.0,13.86,47.85,13.19,40.57,0.005530139999999999,-0.11263890000000001,44.6,1.6488659225380173,13.865750193867905,3.42472290738362e-12,0.1518002972481646,365.8923807296025,2.9833320613351573,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,506.6,2.37,,,66.0,13.86,47.85,13.19,40.57,0.00694386,-0.1139787,45.01,1.6645714540734928,13.865390859539175,4.505206433536318e-12,0.1490612398253961,383.23921693739794,3.9437729380144386,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,500.1,2.37,,,66.0,13.86,47.85,13.19,40.57,0.0058350599999999996,-0.13460205,45.9,1.7666615399413215,13.863293940748207,2.378423894679303e-11,0.13148215621424594,553.240890086866,0.8219840827046873,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,500.1,2.37,,,66.0,13.86,47.85,13.19,40.57,0.0058350599999999996,-0.13460205,45.9,1.7666615399413215,13.863293940748207,2.378423894679303e-11,0.13148215621424594,553.240890086866,0.8219840827046873,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN535N-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,535.0,500.1,2.37,,,66.0,13.86,47.85,13.19,40.57,0.0058350599999999996,-0.13460205,45.9,1.7666615399413215,13.863293940748207,2.378423894679303e-11,0.13148215621424594,553.240890086866,0.8219840827046873,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,540.0,505.7,2.58,,,72.0,13.85,49.65,12.97,41.65,0.00599705,-0.1259124,45.83,1.7926216929646548,13.868248005582332,1.2646870937007062e-11,0.18138941258900704,137.6722162935809,6.370025521588021,-0.3213,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,540.0,504.4,2.58,,,72.0,13.85,49.65,12.97,41.65,0.005373800000000001,-0.1286928,45.99,1.8063907422270664,13.867757959178059,1.5624806101220985e-11,0.1789951673899796,139.60405302871882,5.924003764381798,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,498.6,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008351550000000001,-0.1447794,46.45,1.9590895289328698,13.862816744795081,1.3360779824392003e-10,0.1528825890796744,165.20761984404365,11.60349442815548,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,498.6,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008351550000000001,-0.1447794,46.45,1.9590895289328698,13.862816744795081,1.3360779824392003e-10,0.1528825890796744,165.20761984404365,11.60349442815548,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,498.6,2.54,,,72.0,13.85,49.65,12.97,41.65,0.008351550000000001,-0.1447794,46.45,1.9590895289328698,13.862816744795081,1.3360779824392003e-10,0.1528825890796744,165.20761984404365,11.60349442815548,-0.3786,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,499.4,2.54,,,72.0,13.85,49.65,12.97,41.65,0.007728300000000001,-0.14552415000000002,45.81,1.96051995007186,13.862774644756835,1.3610604617506036e-10,0.15264166815473734,165.49087591358216,11.249691366149868,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,499.4,2.54,,,72.0,13.85,49.65,12.97,41.65,0.007728300000000001,-0.14552415000000002,45.81,1.96051995007186,13.862774644756835,1.3610604617506036e-10,0.15264166815473734,165.49087591358216,11.249691366149868,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,511.4,2.37,,,66.0,13.91,48.09,13.24,40.79,0.00696891,-0.11455038000000001,45.01,1.6730996323007497,13.915247975716264,4.536209475379781e-12,0.14787359396399127,391.9457346177439,3.971018194448445,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,511.4,2.37,,,66.0,13.91,48.09,13.24,40.79,0.00696891,-0.11455038000000001,45.01,1.6730996323007497,13.915247975716264,4.536209475379781e-12,0.14787359396399127,391.9457346177439,3.971018194448445,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,511.4,2.37,,,66.0,13.91,48.09,13.24,40.79,0.00696891,-0.11455038000000001,45.01,1.6730996323007497,13.915247975716264,4.536209475379781e-12,0.14787359396399127,391.9457346177439,3.971018194448445,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,511.4,2.37,,,66.0,13.91,48.09,13.24,40.79,0.00696891,-0.11455038000000001,45.01,1.6730996323007497,13.915247975716264,4.536209475379781e-12,0.14787359396399127,391.9457346177439,3.971018194448445,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,540.0,511.8,2.3746,,,66.0,13.91,48.09,13.24,40.79,0.00555009,-0.11320386000000002,44.6,1.65731126524799,13.915603985915675,3.448248636844005e-12,0.1506173648488681,373.8566762618734,3.0102233850666917,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,540.0,511.8,2.3746,,,66.0,13.91,48.09,13.24,40.79,0.00555009,-0.11320386000000002,44.6,1.65731126524799,13.915603985915675,3.448248636844005e-12,0.1506173648488681,373.8566762618734,3.0102233850666917,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,540.0,511.8,2.3746,,,66.0,13.91,48.09,13.24,40.79,0.00555009,-0.11320386000000002,44.6,1.65731126524799,13.915603985915675,3.448248636844005e-12,0.1506173648488681,373.8566762618734,3.0102233850666917,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,540.0,511.8,2.3746,,,66.0,13.91,48.09,13.24,40.79,0.00555009,-0.11320386000000002,44.6,1.65731126524799,13.915603985915675,3.448248636844005e-12,0.1506173648488681,373.8566762618734,3.0102233850666917,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,511.4,2.37,,,66.0,13.91,48.09,13.24,40.79,0.00696891,-0.11455038000000001,45.01,1.6730996323007497,13.915247975716264,4.536209475379781e-12,0.14787359396399127,391.9457346177439,3.971018194448445,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,504.9,2.37,,,66.0,13.91,48.09,13.24,40.79,0.0058561099999999994,-0.13527717,45.9,1.7757273750858815,13.913173230404823,2.3948982306720755e-11,0.13026440078924184,571.0199413960153,0.8483238175547199,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,504.9,2.37,,,66.0,13.91,48.09,13.24,40.79,0.0058561099999999994,-0.13527717,45.9,1.7757273750858815,13.913173230404823,2.3948982306720755e-11,0.13026440078924184,571.0199413960153,0.8483238175547199,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN540N-132MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,540.0,504.9,2.37,,,66.0,13.91,48.09,13.24,40.79,0.0058561099999999994,-0.13527717,45.9,1.7757273750858815,13.913173230404823,2.3948982306720755e-11,0.13026440078924184,571.0199413960153,0.8483238175547199,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,545.0,510.5,2.58,,,72.0,13.92,49.81,13.04,41.8,0.006027359999999999,-0.12631816,45.83,1.7984403271522456,13.937933224683972,1.272363381523901e-11,0.17970715654959293,139.4910101376708,6.3774134917637175,-0.3213,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,545.0,509.2,2.58,,,72.0,13.92,49.81,13.04,41.8,0.00540096,-0.12910752,45.99,1.8122540635876234,13.937446355584765,1.5719567106193965e-11,0.1773175754496129,141.47714897665102,5.931287096596254,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144M,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,503.4,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00839376,-0.14524596000000004,46.45,1.965453074545775,13.932541643134604,1.3441949486434862e-10,0.15125505382226526,167.8783520310379,11.611410900033826,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144M-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,503.4,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00839376,-0.14524596000000004,46.45,1.965453074545775,13.932541643134604,1.3441949486434862e-10,0.15125505382226526,167.8783520310379,11.611410900033826,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144M-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,503.4,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00839376,-0.14524596000000004,46.45,1.965453074545775,13.932541643134604,1.3441949486434862e-10,0.15125505382226526,167.8783520310379,11.611410900033826,-0.3786,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,504.2,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00776736,-0.14599311000000004,45.81,1.9668879473781054,13.93249990288346,1.3693251342991578e-10,0.15101463353805597,168.17120620662365,11.25753128304291,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,504.2,2.54,,,72.0,13.92,49.81,13.04,41.8,0.00776736,-0.14599311000000004,45.81,1.9668879473781054,13.93249990288346,1.3693251342991578e-10,0.15101463353805597,168.17120620662365,11.25753128304291,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,516.3,2.37,,,66.0,13.97,48.3,13.29,41.01,0.006998970000000001,-0.11505059999999999,45.01,1.6816200874639624,13.975564169660887,4.648020408398057e-12,0.14425464329519924,362.18115090216327,4.145935736892467,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,516.3,2.37,,,66.0,13.97,48.3,13.29,41.01,0.006998970000000001,-0.11505059999999999,45.01,1.6816200874639624,13.975564169660887,4.648020408398057e-12,0.14425464329519924,362.18115090216327,4.145935736892467,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,516.3,2.37,,,66.0,13.97,48.3,13.29,41.01,0.006998970000000001,-0.11505059999999999,45.01,1.6816200874639624,13.975564169660887,4.648020408398057e-12,0.14425464329519924,362.18115090216327,4.145935736892467,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,516.3,2.37,,,66.0,13.97,48.3,13.29,41.01,0.006998970000000001,-0.11505059999999999,45.01,1.6816200874639624,13.975564169660887,4.648020408398057e-12,0.14425464329519924,362.18115090216327,4.145935736892467,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,545.0,516.6,2.3746,,,66.0,13.97,48.3,13.29,41.01,0.005574030000000001,-0.1136982,44.6,1.6657391355967603,13.975923065283224,3.5331962693447013e-12,0.14700642850913193,346.7258438312626,3.1837380161587854,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-DG-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,545.0,516.6,2.3746,,,66.0,13.97,48.3,13.29,41.01,0.005574030000000001,-0.1136982,44.6,1.6657391355967603,13.975923065283224,3.5331962693447013e-12,0.14700642850913193,346.7258438312626,3.1837380161587854,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-DG-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,545.0,516.6,2.3746,,,66.0,13.97,48.3,13.29,41.01,0.005574030000000001,-0.1136982,44.6,1.6657391355967603,13.975923065283224,3.5331962693447013e-12,0.14700642850913193,346.7258438312626,3.1837380161587854,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-DG-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,545.0,516.6,2.3746,,,66.0,13.97,48.3,13.29,41.01,0.005574030000000001,-0.1136982,44.6,1.6657391355967603,13.975923065283224,3.5331962693447013e-12,0.14700642850913193,346.7258438312626,3.1837380161587854,-0.2908,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN545N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,545.0,516.3,2.37,,,66.0,13.97,48.3,13.29,41.01,0.006998970000000001,-0.11505059999999999,45.01,1.6816200874639624,13.975564169660887,4.648020408398057e-12,0.14425464329519924,362.18115090216327,4.145935736892467,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,550.0,515.3,2.58,,,72.0,13.99,49.92,13.1,42.0,0.006057669999999999,-0.12659712,45.83,1.8050847202652978,14.007525578828005,1.3313154786373292e-11,0.16975387273915632,135.5080313119813,6.729953105226713,-0.3213,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,550.0,514.0,2.58,,,72.0,13.99,49.92,13.1,42.0,0.00542812,-0.12939264,45.99,1.8189758990867921,14.007043285593939,1.644928548725045e-11,0.16735725743399874,137.37539188220626,6.282111029978544,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,508.9,2.54,,,72.0,13.99,49.92,13.1,42.0,0.0078064200000000005,-0.14631552000000003,45.81,1.9744058099397623,14.002153253640884,1.432318110300975e-10,0.14098901667379626,162.2969810084504,11.619627582478941,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,508.9,2.54,,,72.0,13.99,49.92,13.1,42.0,0.0078064200000000005,-0.14631552000000003,45.81,1.9744058099397623,14.002153253640884,1.432318110300975e-10,0.14098901667379626,162.2969810084504,11.619627582478941,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,521.1,2.37,,,66.0,14.03,48.51,13.34,41.23,0.00702903,-0.11555082,45.01,1.6901424723200238,14.0358579459024,4.761687746285941e-12,0.14066241009848177,336.89174512117296,4.3196139851249455,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,521.1,2.37,,,66.0,14.03,48.51,13.34,41.23,0.00702903,-0.11555082,45.01,1.6901424723200238,14.0358579459024,4.761687746285941e-12,0.14066241009848177,336.89174512117296,4.3196139851249455,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,521.1,2.37,,,66.0,14.03,48.51,13.34,41.23,0.00702903,-0.11555082,45.01,1.6901424723200238,14.0358579459024,4.761687746285941e-12,0.14066241009848177,336.89174512117296,4.3196139851249455,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,521.1,2.37,,,66.0,14.03,48.51,13.34,41.23,0.00702903,-0.11555082,45.01,1.6901424723200238,14.0358579459024,4.761687746285941e-12,0.14066241009848177,336.89174512117296,4.3196139851249455,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,550.0,521.1,2.37,,,66.0,14.03,48.51,13.34,41.23,0.00702903,-0.11555082,45.01,1.6901424723200238,14.0358579459024,4.761687746285941e-12,0.14066241009848177,336.89174512117296,4.3196139851249455,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,550.0,517.4,2.58,,,72.0,14.02,50.31,13.22,41.64,0.00517338,-0.12235391999999999,45.61,1.7475678600306,14.036883111101146,4.331675732979977e-12,0.23965841860717033,199.01610660730447,1.5884694609683,-0.3048,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN550N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,550.0,517.2,2.58,,,72.0,14.02,50.31,13.22,41.64,0.00499112,-0.12240422999999999,45.71,1.7469108127165738,14.036907930951052,4.284954602327214e-12,0.23977059062507416,198.81697503296826,1.4749251840457354,-0.3057,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,555.0,520.1,2.58,,,72.0,14.07,50.04,13.17,42.15,0.006092310000000001,-0.12690143999999998,45.83,1.8107992326075482,14.087518158942865,1.3666075822210868e-11,0.16489328893951946,132.43678103704056,6.910104484450424,-0.3213,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,555.0,518.8,2.58,,,72.0,14.07,50.04,13.17,42.15,0.005459160000000001,-0.12970368,45.99,1.8247483086552139,14.087034167934116,1.6886153182525588e-11,0.16249727736287464,134.22062686041195,6.461437097468582,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,513.7,2.54,,,72.0,14.07,50.04,13.17,42.15,0.007851060000000002,-0.14666724,45.81,1.9807848952348837,14.082130036935151,1.4700341002149897e-10,0.13614269091765296,157.91606292905007,11.804517382361267,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,513.7,2.54,,,72.0,14.07,50.04,13.17,42.15,0.007851060000000002,-0.14666724,45.81,1.9807848952348837,14.082130036935151,1.4700341002149897e-10,0.13614269091765296,157.91606292905007,11.804517382361267,-0.3829,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-132BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,526.0,2.37,,,66.0,14.08,48.75,13.4,41.43,0.00705408,-0.11612249999999999,45.01,1.69770806857341,14.085250211022348,4.7199068215145376e-12,0.14129385357036273,378.92142884446724,4.2089126413451545,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-132BMH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,526.0,2.37,,,66.0,14.08,48.75,13.4,41.43,0.00705408,-0.11612249999999999,45.01,1.69770806857341,14.085250211022348,4.7199068215145376e-12,0.14129385357036273,378.92142884446724,4.2089126413451545,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-132BMH-BT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,526.0,2.37,,,66.0,14.08,48.75,13.4,41.43,0.00705408,-0.11612249999999999,45.01,1.69770806857341,14.085250211022348,4.7199068215145376e-12,0.14129385357036273,378.92142884446724,4.2089126413451545,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-132BMH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,526.0,2.37,,,66.0,14.08,48.75,13.4,41.43,0.00705408,-0.11612249999999999,45.01,1.69770806857341,14.085250211022348,4.7199068215145376e-12,0.14129385357036273,378.92142884446724,4.2089126413451545,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-132BMH-WT,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,555.0,526.0,2.37,,,66.0,14.08,48.75,13.4,41.43,0.00705408,-0.11612249999999999,45.01,1.69770806857341,14.085250211022348,4.7199068215145376e-12,0.14129385357036273,378.92142884446724,4.2089126413451545,-0.2885,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,555.0,522.2,2.58,,,72.0,14.08,50.5,13.28,41.8,0.00519552,-0.122816,45.61,1.7540184564304215,14.096645634524425,4.3408517178362785e-12,0.23930635721662036,202.4214522903568,1.5693155150755165,-0.3048,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN555N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,555.0,522.0,2.58,,,72.0,14.08,50.5,13.28,41.8,0.005012480000000001,-0.12286649999999999,45.71,1.7533589880805114,14.096670402131545,4.294027925763644e-12,0.23941843306500274,202.2153703457059,1.45578206386823,-0.3057,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN560-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,560.0,524.9,2.58,,,72.0,14.16,50.14,13.26,42.24,0.00613128,-0.12715504000000002,45.83,1.8141588370520283,14.177246764393676,1.3706138595338796e-11,0.1637249026075164,134.4220036161232,6.878191348553276,-0.3213,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN560-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,560.0,523.6,2.58,,,72.0,14.16,50.14,13.26,42.24,0.00549408,-0.12996288,45.99,1.8281307329350716,14.176765385555138,1.693539384019745e-11,0.16134126922215627,136.26840673696725,6.429598451452523,-0.331,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN560-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,560.0,518.5,2.54,,,72.0,14.16,50.14,13.26,42.24,0.00790128,-0.14696034000000002,45.81,1.984436253687649,14.171892053724166,1.4744046562266588e-10,0.13512050869434747,160.88948855928618,11.772041435553875,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN560-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,560.0,518.5,2.54,,,72.0,14.16,50.14,13.26,42.24,0.00790128,-0.14696034000000002,45.81,1.984436253687649,14.171892053724166,1.4744046562266588e-10,0.13512050869434747,160.88948855928618,11.772041435553875,-0.3829,N,2025.7.3,6/23/2025,2.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN560N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,560.0,527.1,2.58,,,72.0,14.13,50.67,13.34,41.95,0.005213970000000001,-0.12322944000000001,45.61,1.759344808482809,14.145552404559103,4.32000532005552e-12,0.23848135826265596,216.6701351522217,1.4951526894899385,-0.3048,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN560N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,560.0,526.8,2.58,,,72.0,14.13,50.67,13.34,41.95,0.005030280000000001,-0.12328011,45.71,1.758683382477602,14.145576698278866,4.273394482229497e-12,0.23859323802919438,216.43370139341357,1.3816941424284566,-0.3057,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN565N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,565.0,531.9,2.58,,,72.0,14.19,50.87,13.41,42.14,0.00523611,-0.12371583999999998,45.61,1.7659842336027383,14.20437943148584,4.321621771960839e-12,0.23634774396165245,233.23415121042433,1.4586115239109343,-0.3048,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN565N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,565.0,531.6,2.58,,,72.0,14.19,50.87,13.41,42.14,0.00505164,-0.12376670999999997,45.71,1.7653201594086279,14.204403152847146,4.274974426282543e-12,0.23645952457327468,232.96015121908684,1.3451177763641413,-0.3057,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN570N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,570.0,535.6,2.58,,,72.0,13.72,51.58,13.06,43.65,0.007312760000000001,-0.12925948,46.07,1.8464655934636363,13.724200790925483,1.0059511470967918e-11,0.16009528862999756,522.8794800193127,5.533905906500955,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN570N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,570.0,536.5,2.58,,,72.0,14.25,51.07,13.48,42.34,0.005073,-0.12425331,45.71,1.7721569877103156,14.263221025959066,4.290433324895672e-12,0.23350235355587817,251.67551755887223,1.3358482964026528,-0.3057,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN570N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,570.0,535.8,2.58,,,72.0,13.72,51.58,13.06,43.65,0.007408800000000001,-0.12956896,45.86,1.8497998900885655,13.724136447049517,1.0579849785818524e-11,0.15951634962145494,529.0927948754371,5.705040089979762,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN570N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,570.0,535.8,2.58,,,72.0,13.72,51.58,13.06,43.65,0.007408800000000001,-0.12956896,45.86,1.8497998900885655,13.724136447049517,1.0579849785818524e-11,0.15951634962145494,529.0927948754371,5.705040089979762,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN570N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,570.0,535.8,2.58,,,72.0,13.72,51.58,13.06,43.65,0.007408800000000001,-0.12956896,45.86,1.8497998900885655,13.724136447049517,1.0579849785818524e-11,0.15951634962145494,529.0927948754371,5.705040089979762,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN575N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,575.0,540.4,2.58,,,72.0,13.77,51.81,13.11,43.86,0.007339409999999999,-0.12983586,46.07,1.8548547156062105,13.774069601899633,1.012170532801172e-11,0.1589122282669148,537.6991289798916,5.555023705545941,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN575N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,575.0,541.3,2.58,,,72.0,14.31,51.26,13.54,42.53,0.00509436,-0.12471557999999998,45.71,1.7792032612824618,14.322908610299548,4.341142126402863e-12,0.23065938028603447,255.70031566742713,1.398033607652952,-0.3057,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN575N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,575.0,540.7,2.58,,,72.0,13.77,51.81,13.11,43.86,0.007435799999999999,-0.13014672,45.86,1.8582044418034864,13.774005864569741,1.0645260529135142e-11,0.15833270940351926,544.2623897131306,5.726187959265401,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN575N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,575.0,540.7,2.58,,,72.0,13.77,51.81,13.11,43.86,0.007435799999999999,-0.13014672,45.86,1.8582044418034864,13.774005864569741,1.0645260529135142e-11,0.15833270940351926,544.2623897131306,5.726187959265401,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN575N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,575.0,540.7,2.58,,,72.0,13.77,51.81,13.11,43.86,0.007435799999999999,-0.13014672,45.86,1.8582044418034864,13.774005864569741,1.0645260529135142e-11,0.15833270940351926,544.2623897131306,5.726187959265401,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN580N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,580.0,545.2,2.58,,,72.0,13.83,52.02,13.16,44.08,0.00737139,-0.13036212,46.07,1.8637076583403305,13.834410808307567,1.0363783401124622e-11,0.1551446019743836,486.45275564738176,5.724477693894512,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN580N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,580.0,550.8,2.583252,,,72.0,13.83,52.02,13.16,44.08,0.00690117,-0.12089448,44.8,1.779418986923244,13.836145125131733,2.7570395653039907e-12,0.16981112553166747,382.1708751561353,2.3378715154236556,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN580N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,580.0,545.5,2.58,,,72.0,13.83,52.02,13.16,44.08,0.0074682,-0.13067424,45.86,1.867075562951894,13.834346483155285,1.0899821163429028e-11,0.15456368999350936,491.80356272551523,5.895818207723367,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN580N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,580.0,545.5,2.58,,,72.0,13.83,52.02,13.16,44.08,0.0074682,-0.13067424,45.86,1.867075562951894,13.834346483155285,1.0899821163429028e-11,0.15456368999350936,491.80356272551523,5.895818207723367,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN580N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,580.0,545.5,2.58,,,72.0,13.83,52.02,13.16,44.08,0.0074682,-0.13067424,45.86,1.867075562951894,13.834346483155285,1.0899821163429028e-11,0.15456368999350936,491.80356272551523,5.895818207723367,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN585N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,585.0,550.0,2.58,,,72.0,13.88,52.25,13.21,44.29,0.007398040000000001,-0.13093849999999999,46.07,1.8720963208268568,13.884280624766744,1.0426225445568125e-11,0.1539895570783319,499.3139679929582,5.744519857706051,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN585N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,585.0,555.6,2.583252,,,72.0,13.88,52.25,13.21,44.29,0.00692612,-0.121429,44.8,1.7874217296327992,13.88600011696401,2.7736457172827336e-12,0.1686703668812401,390.1831764580756,2.3575178138834643,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN585N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,585.0,550.3,2.58,,,72.0,13.88,52.25,13.21,44.29,0.0074952000000000005,-0.13125199999999998,45.86,1.875479652280168,13.884216890639522,1.09654928868784e-11,0.15340807681317742,504.94649623668096,5.915890448494638,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN585N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,585.0,550.3,2.58,,,72.0,13.88,52.25,13.21,44.29,0.0074952000000000005,-0.13125199999999998,45.86,1.875479652280168,13.884216890639522,1.09654928868784e-11,0.15340807681317742,504.94649623668096,5.915890448494638,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN585N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,585.0,550.3,2.58,,,72.0,13.88,52.25,13.21,44.29,0.0074952000000000005,-0.13125199999999998,45.86,1.875479652280168,13.884216890639522,1.09654928868784e-11,0.15340807681317742,504.94649623668096,5.915890448494638,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN590N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,590.0,554.9,2.58,,,72.0,13.93,52.48,13.26,44.5,0.00742469,-0.13151487999999997,46.07,1.8804845936730523,13.934152341243392,1.0488626685782696e-11,0.15284340059063442,512.7489424618649,5.764340915166502,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN590N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,590.0,560.5,2.583252,,,72.0,13.93,52.48,13.26,44.5,0.00695107,-0.12196351999999998,44.8,1.7954241021559292,13.93585706151459,2.790240251441923e-12,0.16753838445919558,398.46084825908184,2.3769417648478943,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN590N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,590.0,555.1,2.58,,,72.0,13.93,52.48,13.26,44.5,0.007522200000000001,-0.13182975999999996,45.86,1.8838833387991494,13.934089216860972,1.1031119332555786e-11,0.15226136066798845,518.6813808022597,5.935736619808964,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN590N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,590.0,555.1,2.58,,,72.0,13.93,52.48,13.26,44.5,0.007522200000000001,-0.13182975999999996,45.86,1.8838833387991494,13.934089216860972,1.1031119332555786e-11,0.15226136066798845,518.6813808022597,5.935736619808964,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN590N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,590.0,555.1,2.58,,,72.0,13.93,52.48,13.26,44.5,0.007522200000000001,-0.13182975999999996,45.86,1.8838833387991494,13.934089216860972,1.1031119332555786e-11,0.15226136066798845,518.6813808022597,5.935736619808964,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN595N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,595.0,559.7,2.58,,,72.0,13.98,52.69,13.31,44.71,0.007451340000000001,-0.13204114,46.07,1.8885023397780512,13.984005064555685,1.0604802760528556e-11,0.15019706369417057,524.2749313469333,5.828105422073437,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN595N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,595.0,565.3,2.583252,,,72.0,13.98,52.69,13.31,44.71,0.00697602,-0.12245156,44.8,1.8030573983032636,13.985684603298257,2.8211269746579968e-12,0.16490977437703208,405.5584055214635,2.4395155663237236,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN595N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,595.0,560.0,2.58,,,72.0,13.98,52.69,13.31,44.71,0.007549200000000001,-0.13235728,45.86,1.8919164318503658,13.983942964266111,1.1153297533455813e-11,0.1496143244617826,530.4659238631228,5.999580094031841,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN595N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,595.0,560.0,2.58,,,72.0,13.98,52.69,13.31,44.71,0.007549200000000001,-0.13235728,45.86,1.8919164318503658,13.983942964266111,1.1153297533455813e-11,0.1496143244617826,530.4659238631228,5.999580094031841,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN595N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,595.0,560.0,2.58,,,72.0,13.98,52.69,13.31,44.71,0.007549200000000001,-0.13235728,45.86,1.8919164318503658,13.983942964266111,1.1153297533455813e-11,0.1496143244617826,530.4659238631228,5.999580094031841,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN600N-144BMH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,600.0,564.5,2.58,,,72.0,14.03,52.9,13.36,44.92,0.00747799,-0.1325674,46.07,1.8965194011607376,14.03386106276592,1.072135078148811e-11,0.14757095850422136,536.2307558033416,5.891278102358778,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN600N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,600.0,570.2,2.583252,,,72.0,14.03,52.9,13.36,44.92,0.0070009700000000005,-0.12293960000000001,44.8,1.8106900582880228,14.035515496989555,2.8521123451442872e-12,0.1623012479786643,412.8524623119791,2.501506657536027,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN600N-144MH,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,600.0,564.8,2.58,,,72.0,14.03,52.9,13.36,44.92,0.0075762,-0.1328848,45.86,1.8999487845930245,14.033799960439081,1.1275858441199928e-11,0.14698753414709292,542.6990993963303,6.0628246323077075,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN600N-144MH-BB,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,600.0,564.8,2.58,,,72.0,14.03,52.9,13.36,44.92,0.0075762,-0.1328848,45.86,1.8999487845930245,14.033799960439081,1.1275858441199928e-11,0.14698753414709292,542.6990993963303,6.0628246323077075,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN600N-144MH-BW,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,600.0,564.8,2.58,,,72.0,14.03,52.9,13.36,44.92,0.0075762,-0.1328848,45.86,1.8999487845930245,14.033799960439081,1.1275858441199928e-11,0.14698753414709292,542.6990993963303,6.0628246323077075,-0.3091,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN605N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,605.0,572.3,2.701,,,66.0,15.8,48.1,14.89,40.64,0.0073628,-0.1132755,45.2,1.6731170604629801,15.815226590583864,5.065350099735858e-12,0.14214415670685948,147.49708156744126,5.120287931173676,-0.2899,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN605N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,605.0,575.1,2.583252,,,72.0,14.08,53.12,13.41,45.12,0.007025920000000001,-0.12345088,44.8,1.8183208569557365,14.085382626704687,2.8674253959813027e-12,0.16130302285621698,421.9401957963152,2.5160835053279436,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN610N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,610.0,577.1,2.701,,,66.0,15.85,48.3,14.94,40.83,0.0073861000000000005,-0.11374649999999999,45.2,1.6803340571676508,15.864961069903723,5.1049679440358596e-12,0.14070248392827267,149.06249263863097,5.159713024358017,-0.2899,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN610N-144BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,610.0,579.9,2.583252,,,72.0,14.13,53.34,13.46,45.32,0.007050870000000001,-0.12396216000000002,44.8,1.8259513854718703,14.135251410779011,2.882729250309964e-12,0.1603123401118798,431.35329975374145,2.5305039102061326,-0.276,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN610N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,610.0,574.6,2.8,,,78.0,13.6,55.81,12.95,47.11,0.007697600000000001,-0.13204646,45.62,1.9778897197162137,13.604360089304265,7.519215055525996e-12,0.18834374534047546,587.482221135138,9.226172807635416,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN615N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,615.0,582.0,2.701,,,66.0,15.9,48.5,14.99,41.03,0.007409400000000001,-0.11421749999999999,45.2,1.6877447944705417,15.91463116678143,5.161536277845382e-12,0.13851303930547834,150.52505897694363,5.227425769997634,-0.2899,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN615N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,615.0,579.4,2.8,,,78.0,13.65,56.02,13.0,47.31,0.0077259,-0.13254332000000002,45.62,1.9856174934797097,13.654217503007258,7.578833383298593e-12,0.18639040484088218,603.2548409273135,9.263429818098075,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN620N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,620.0,586.8,2.701,,,66.0,15.95,48.7,15.04,41.23,0.0074327,-0.1146885,45.2,1.6951546506777455,15.96430613415766,5.2182460506687146e-12,0.13633859860176106,152.0047712261467,5.294416957351028,-0.2899,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN620N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,620.0,584.3,2.8,,,78.0,13.71,56.18,13.06,47.48,0.0077598599999999995,-0.13292188,45.62,1.9917823296895627,13.714043326161963,7.667017509698615e-12,0.18309149615502276,620.8216412231693,9.327153632044148,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN625N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,625.0,591.7,2.701,,,66.0,16.0,48.9,15.08,41.45,0.007456000000000001,-0.1151595,45.2,1.7034725972596292,16.014395821622283,5.352194102546517e-12,0.13261292294949242,147.39045948675349,5.490099528220458,-0.2899,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN625N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,625.0,589.1,2.8,,,78.0,13.76,56.38,13.11,47.68,0.00778816,-0.13339508000000003,45.62,1.9993224548032984,13.763899764157143,7.745107537348572e-12,0.18040952168389482,636.5602983503464,9.384863381660887,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN630N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,630.0,596.5,2.701,,,66.0,16.05,49.1,15.12,41.67,0.0074793,-0.11563050000000001,45.2,1.7117931810752076,16.064458238183832,5.488573245035288e-12,0.12890655543011892,143.09836261048906,5.684562528680798,-0.2899,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN630N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,630.0,593.9,2.8,,,78.0,13.82,56.56,13.16,47.89,0.00782212,-0.13382096,45.62,2.0073474997940615,13.82425728413918,7.954495349899e-12,0.17514473720378085,568.5550224406034,9.588554158700559,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN635N-132BMHR-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,635.0,601.4,2.701,,,66.0,16.1,49.3,15.16,41.89,0.007502600000000001,-0.1161015,45.2,1.7201158023826881,16.114493513962504,5.627355222333901e-12,0.12521942277824769,139.0989556845617,5.877736018744208,-0.2899,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN635N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,635.0,598.8,2.8,,,78.0,13.87,56.76,13.22,48.05,0.007850419999999999,-0.13429416,45.62,2.013400777343888,13.873608074470296,7.876133607541828e-12,0.1760473622137707,676.7534887921065,9.462590445720354,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN640N-156BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,0,640.0,603.6,2.8,,,78.0,13.93,56.92,13.27,48.24,0.00788438,-0.13467272000000002,45.62,2.0206539361000413,13.933964051524795,8.080327273352466e-12,0.1710447689973326,601.0652533653976,9.656948933507556,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Vietnam Sunergy Joint Stock Company VSUN680N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,680.0,641.3,3.106352,,,66.0,18.18,47.4,17.16,39.6,0.006381179999999999,-0.11205359999999999,45.1,1.6451941704636175,18.19864770933648,5.492006911687485e-12,0.15071170082756014,146.93165122940223,4.360044242366865,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN685N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,685.0,646.1,3.106352,,,66.0,18.21,47.7,17.19,39.8,0.00639171,-0.11276280000000001,45.1,1.6545407132878096,18.22885934967118,5.4011347027210594e-12,0.15477084941473832,149.44190656329917,4.201764773871971,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN690N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,690.0,651.0,3.106352,,,66.0,18.25,47.9,17.23,40.1,0.00640575,-0.11323559999999999,45.1,1.6639886555374974,18.267926032511895,5.652803046790442e-12,0.14629285007385692,148.93672179651517,4.574818395742678,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN695N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,695.0,655.8,3.106352,,,66.0,18.28,48.3,17.25,40.3,0.006416280000000001,-0.1141812,45.1,1.6756070209607228,18.29939869172078,5.443455480255864e-12,0.1561478042265084,147.14300868735845,4.23747414887498,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN700N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,700.0,660.6,3.106352,,,66.0,18.32,48.5,17.29,40.5,0.00643032,-0.11465399999999999,45.1,1.6830959995390087,18.3390675735381,5.5074835927882835e-12,0.15427591765031062,148.22729201877306,4.3187493967280615,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN705N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,705.0,665.5,3.106352,,,66.0,18.37,48.7,17.33,40.7,0.00644787,-0.11512680000000002,45.1,1.691001421386032,18.389447643328463,5.610929659937551e-12,0.15230988161002387,143.8700037550285,4.457505066775576,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vietnam Sunergy Joint Stock Company VSUN710N-132BMH-DG,Vietnam Sunergy Joint Stock Company,Mono-c-Si,1,710.0,670.3,3.106352,,,66.0,18.42,48.9,17.36,40.9,0.006465420000000001,-0.1155996,45.1,1.699354245495848,18.440536701034425,5.755022856819916e-12,0.15032917821783867,134.83487251764194,4.65727719831394,-0.3036,N,2025.7.3,6/23/2025,4.0,bootstrapping +Vikram Solar SOMERA VSMHBB6035005,Vikram Solar,Mono-c-Si,0,350.0,322.9,1.86,,,60.0,11.13,40.8,10.13,34.6,0.00540918,-0.1174224,46.53,1.6002427294463812,11.150527735913718,8.888910727984709e-11,0.11781635484283055,63.879233546216874,11.655476796085178,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT6035505,Vikram Solar,Mono-c-Si,1,355.0,317.1,1.86,,,60.0,11.25,40.8,10.27,34.7,0.00324,-0.1535304,47.18,1.8219528483658538,11.258680529345465,2.0179180162602526e-09,0.058726359062763786,76.10959887105889,9.781594608045568,-0.4909,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMHBB6035505,Vikram Solar,Mono-c-Si,0,355.0,327.7,1.86,,,60.0,11.25,40.8,10.27,34.7,0.0054675,-0.1174224,46.53,1.6001071747770517,11.267744280680777,8.995189969399802e-11,0.10597602394737755,67.18955237154265,11.655088249317226,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT6036005,Vikram Solar,Mono-c-Si,1,360.0,321.7,1.86,,,60.0,11.35,40.9,10.41,34.7,0.0032688,-0.1539067,47.18,1.818295222280404,11.359226456160025,1.8529578572467156e-09,0.069675615895825,85.71203430886196,8.927865819385483,-0.4909,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSM7236005,Vikram Solar,Mono-c-Si,0,360.0,330.9,1.88,,,72.0,9.64,48.1,9.07,39.73,0.0038251520000000005,-0.14592578,45.1,1.907954798993952,9.647612350985543,1.0708512434279911e-10,0.2858924822006967,362.043691505127,8.690213444083179,-0.40969,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMHBB6036005,Vikram Solar,Mono-c-Si,0,360.0,332.4,1.86,,,60.0,11.35,40.9,10.41,34.7,0.0055160999999999995,-0.11771019999999999,46.53,1.5977318984061837,11.367677833686757,8.255334057869194e-11,0.11589064767019773,74.40724255086234,10.785693483496116,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT6036505,Vikram Solar,Mono-c-Si,1,365.0,326.4,1.86,,,60.0,11.45,41.0,10.53,34.8,0.0032975999999999995,-0.15428300000000003,47.18,1.8201891636539826,11.4585109086115,1.8170615803771715e-09,0.06842285175238288,92.05148102249208,8.667893531063584,-0.4909,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSM7236505,Vikram Solar,Mono-c-Si,0,365.0,335.7,1.88,,,72.0,9.74,48.3,9.16,39.86,0.003864832,-0.14653254,45.1,1.9154074689028453,9.748077178143198,1.0746682180128328e-10,0.28854763714456744,347.94999698657904,8.632617842802231,-0.40969,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMHBB6036505,Vikram Solar,Mono-c-Si,0,365.0,337.1,1.86,,,60.0,11.45,41.0,10.53,34.8,0.005564699999999999,-0.117998,46.53,1.5996630269634997,11.466524945926237,8.094488419505991e-11,0.11408898887602562,79.05132860801356,10.521011452858628,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT6037005,Vikram Solar,Mono-c-Si,1,370.0,331.0,1.86,,,60.0,11.55,41.1,10.65,34.9,0.0033264,-0.15465930000000003,47.18,1.8221486335638084,11.557809221788496,1.7831659935890609e-09,0.06717555633680532,99.3540445829978,8.415832388826715,-0.4909,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSM7237005,Vikram Solar,Mono-c-Si,0,370.0,340.4,1.88,,,72.0,9.84,48.5,9.26,40.0,0.003904512,-0.1471393,45.1,1.9220459782608874,9.84775558554568,1.068325923004213e-10,0.2900312854117431,367.98097963344674,8.488850710841875,-0.40969,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMHBB6037005,Vikram Solar,Mono-c-Si,0,370.0,341.9,1.86,,,60.0,11.55,41.1,10.65,34.9,0.0056133,-0.11828580000000001,46.53,1.601643747698369,11.565391526843833,7.942552915932048e-11,0.11230907088621579,84.27817304615594,10.264241433363654,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT6037505,Vikram Solar,Mono-c-Si,1,375.0,335.7,1.86,,,60.0,11.65,41.1,10.75,34.9,0.0033552,-0.15465930000000003,47.18,1.762834546310768,11.65000193226804,8.727040297937376e-10,0.0779591917527202,470173.4523101655,2.1507277802421436,-0.4909,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSM7237505,Vikram Solar,Mono-c-Si,0,375.0,345.2,1.88,,,72.0,9.94,48.7,9.36,40.1,0.003944192,-0.14774606,45.1,1.9276495773045026,9.947491306637886,1.0478279048585471e-10,0.2964553352130306,393.3581047123252,8.228660507093728,-0.40969,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMDT7237505,Vikram Solar,Mono-c-Si,1,375.0,345.9,2.02,,,72.0,9.99,47.0,9.36,40.1,0.0048951,-0.12737,49.34,1.729624653048648,9.998354610837524,1.538815510057292e-11,0.1513497330171485,180.97597435857568,3.7431233808233753,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMHBB6037505,Vikram Solar,Mono-c-Si,0,375.0,346.7,1.86,,,60.0,11.65,41.1,10.75,34.9,0.0056619,-0.11828580000000001,46.53,1.6010144275431752,11.665232918013643,7.937753239225932e-11,0.1115013874045212,85.27526837385297,10.179190251283329,-0.3645,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT6038005,Vikram Solar,Mono-c-Si,1,380.0,340.3,1.86,,,60.0,11.75,41.2,10.89,34.98,0.0033840000000000003,-0.15503560000000002,47.18,1.7710738480430028,11.750001947018855,9.271767634628339e-10,0.07761763156401424,468562.3773718655,2.579746380341966,-0.4909,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSM7238005,Vikram Solar,Mono-c-Si,0,380.0,349.9,1.88,,,72.0,10.04,48.9,9.45,40.26,0.003983871999999999,-0.14835282,45.1,1.9358806880680448,10.047907125107852,1.0621836759890518e-10,0.29523514292264624,374.8721438086419,8.26174828194831,-0.40969,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMDHT7238005,Vikram Solar,Mono-c-Si,1,380.0,345.8,2.02,,,72.0,10.05,47.2,9.43,40.3,0.007236,-0.12932800000000003,49.19,1.8844934391947603,10.05493338035824,1.3056845782960045e-10,0.11264666721553117,229.47734475215694,21.587892873799248,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMDT7238005,Vikram Solar,Mono-c-Si,1,380.0,350.6,2.02,,,72.0,10.09,47.1,9.45,40.2,0.004944100000000001,-0.127641,49.34,1.7339688329612302,10.098488135707287,1.569708594888126e-11,0.14829873891059414,176.28538597121621,3.828499915934579,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMDHT7238505,Vikram Solar,Mono-c-Si,1,385.0,350.5,2.02,,,72.0,10.17,47.3,9.53,40.4,0.0073224,-0.129602,49.19,1.8901378824308595,10.175276157315379,1.3483575801829053e-10,0.10937883095085821,210.83198751986566,21.793822735827977,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMDT7238505,Vikram Solar,Mono-c-Si,1,385.0,355.4,2.02,,,72.0,10.19,47.3,9.53,40.4,0.0049930999999999994,-0.128183,49.34,1.7432379784815708,10.198893823986669,1.6302092255308915e-11,0.14360749038904333,164.53668635842718,4.070807121676966,-0.322,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMDHT7239005,Vikram Solar,Mono-c-Si,1,390.0,355.2,2.02,,,72.0,10.28,47.4,9.62,40.5,0.0074015999999999995,-0.129876,49.19,1.895830848860229,10.285613878106625,1.391524512033599e-10,0.10626848437269142,194.59632322747035,22.004845268441645,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT5439505,Vikram Solar,Mono-c-Si,1,395.0,364.1,1.9,,,54.0,13.2,37.4,12.58,31.4,0.0068112,-0.1064404,47.18,1.434429013114135,13.200003692701507,6.268609465294746e-11,0.12545785298246,448480.53120469995,8.044085395290244,-0.3699,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT5440005,Vikram Solar,Mono-c-Si,1,400.0,368.9,1.9,,,54.0,13.3,37.5,12.66,31.6,0.0068628000000000005,-0.10672500000000001,47.18,1.439895737496626,13.300003297775879,6.505460246050014e-11,0.11448277440349611,461728.5700834532,8.302129368916251,-0.3699,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT5440505,Vikram Solar,Mono-c-Si,1,405.0,373.6,1.9,,,54.0,13.4,37.6,12.74,31.8,0.0069144,-0.10700960000000001,47.18,1.4507876841300453,13.402447462201216,7.403255587101982e-11,0.10278073206751227,562.7306011830728,9.390010997088334,-0.3699,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT7243505,Vikram Solar,Mono-c-Si,1,435.0,400.2,2.21,,,72.0,11.45,48.7,10.51,41.4,0.00685855,-0.14473640000000002,47.18,1.8748002181185874,11.450003218251018,5.99134528952361e-11,0.13338665260211277,474578.56510199077,4.140190783854139,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMH7243505,Vikram Solar,Mono-c-Si,0,435.0,402.2,2.2,,,72.0,11.45,48.7,10.51,41.4,0.00069845,-0.06720600000000002,46.61,1.8062928436153325,11.47465658385023,1.743249634368215e-11,0.1850240310045332,85.92127649200143,-1.3795826383497787,-0.3594,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT7244005,Vikram Solar,Mono-c-Si,1,440.0,404.9,2.21,,,72.0,11.56,48.8,10.62,41.5,0.0069244400000000005,-0.1450336,47.18,1.8795919693683538,11.560003163976273,6.128172282936279e-11,0.1306840783776451,477482.7370180432,4.249867326938581,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT7244505,Vikram Solar,Mono-c-Si,1,445.0,409.6,2.21,,,72.0,11.67,48.9,10.72,41.5,0.00699033,-0.1453308,47.18,1.8815770657572697,11.68838110829437,5.753505714882325e-11,0.13951179723149665,88.57478312125419,3.794297510498631,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMH7244505,Vikram Solar,Mono-c-Si,0,445.0,411.8,2.2,,,72.0,11.67,48.9,10.72,41.5,0.0007118700000000001,-0.067482,46.61,1.7898977222609178,11.691932359728305,1.5168094620223444e-11,0.1589097932985521,84.55438963699302,100.00000016709043,-0.3594,N,2025.7.3,6/23/2025,2.0,first_pass +Vikram Solar PREXOS VSMDHT7245005,Vikram Solar,Mono-c-Si,1,450.0,414.4,2.21,,,72.0,11.77,49.0,10.82,41.6,0.00705023,-0.145628,47.18,1.9534603189035324,11.78557624997258,1.4380544802990023e-10,0.12305669215985474,92.9862633157983,11.677785898270248,-0.3718,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMH7245005,Vikram Solar,Mono-c-Si,0,450.0,416.5,2.2,,,72.0,11.77,49.0,10.82,41.6,0.0007179700000000001,-0.06762,46.61,1.7931851778122523,11.79153370100108,1.5224469484756533e-11,0.15643278680721404,85.50382969201472,100.0000004485027,-0.3594,N,2025.7.3,6/23/2025,2.0,first_pass +Vikram Solar PREXOS VSMDHT7847505,Vikram Solar,Mono-c-Si,1,475.0,438.2,2.38,,,78.0,11.45,52.8,10.61,44.9,0.006091399999999999,-0.149952,47.41,1.9655787123406139,11.450083892794952,2.4692175277370694e-11,0.15790850430283346,21551.948272780086,1.5550722801116228,-0.3578,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMH7847505,Vikram Solar,Mono-c-Si,0,475.0,438.1,2.38,,,78.0,11.45,52.8,10.61,44.9,0.00628605,-0.1529088,47.05,2.010276124096471,11.450003628116466,4.4878227429032684e-11,0.14838212254898323,468287.9490714151,4.489755695500716,-0.3644,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT7848005,Vikram Solar,Mono-c-Si,1,480.0,442.9,2.38,,,78.0,11.56,52.9,10.69,45.0,0.0061499200000000006,-0.15023599999999998,47.41,1.9920752496734808,11.560003666277296,3.389748715818366e-11,0.15025995518948032,473785.0651578998,4.114489266513016,-0.3578,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMH7848005,Vikram Solar,Mono-c-Si,0,480.0,442.9,2.38,,,78.0,11.56,52.9,10.69,45.0,0.00634644,-0.1531984,47.05,2.0127425495787397,11.56000484140054,4.4523297373154495e-11,0.14589275282495529,348357.9909035496,4.341986853630422,-0.3644,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PREXOS VSMDHT7848505,Vikram Solar,Mono-c-Si,1,485.0,447.7,2.38,,,78.0,11.67,53.0,10.79,45.0,0.00620844,-0.15052,47.41,2.0547825279905383,11.684715412924241,7.052010618910609e-11,0.14614969048604967,115.9034345364306,10.521252804410146,-0.3578,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar SOMERA VSMH7848505,Vikram Solar,Mono-c-Si,0,485.0,447.6,2.38,,,78.0,11.67,53.0,10.79,45.0,0.00640683,-0.153488,47.05,2.075832074617183,11.684102143959109,9.164254919344007e-11,0.14179626218576072,117.34119277174281,10.659147184792198,-0.3644,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PARADEA VSMDH7253505,Vikram Solar,Mono-c-Si,1,535.0,493.2,2.5,,,72.0,13.56,49.4,12.87,41.6,0.0073224,-0.14731080000000002,46.48,1.946340211621702,13.562929150551975,1.2797499741387383e-10,0.14195835558959508,657.1719046640131,8.944761303621322,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PARADEA VSMDH7254005,Vikram Solar,Mono-c-Si,1,540.0,497.7,2.55,,,72.0,13.64,49.5,12.95,41.7,0.007365600000000001,-0.14760900000000002,46.48,1.950359669570197,13.642735009848296,1.2890631463076004e-10,0.1400524089512506,698.4673207850852,8.955614720059998,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PARADEA VSMDH7254505,Vikram Solar,Mono-c-Si,1,545.0,502.4,2.55,,,72.0,13.73,49.6,13.04,41.8,0.0074142,-0.14790720000000002,46.48,1.9543427203544204,13.732521771367242,1.2987795729896915e-10,0.138075016875637,751.7613078712769,8.962490400442476,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PARADEA VSMDH7255005,Vikram Solar,Mono-c-Si,1,550.0,507.5,2.5,,,72.0,13.81333333,49.7,13.12333333,41.9,0.0074591999982000015,-0.14820540000000001,46.48,1.9583542725742404,13.815660894463779,1.3083159083128635e-10,0.13618537969480388,808.2157311010054,8.97240834120337,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +Vikram Solar PARADEA VSMDH7255505,Vikram Solar,Mono-c-Si,1,555.0,512.3,2.5,,,72.0,13.89833333,49.8,13.20833333,42.0,0.0075050999982,-0.1485036,46.48,1.96236193869157,13.9004666818925,1.317964969263258e-10,0.13430388009969957,874.9612675382267,8.981864480891305,-0.386,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-120,WAAREE ENERGIES LIMITED,Multi-c-Si,0,120.0,106.4,0.9834,1.49,0.66,72.0,8.0,21.0,7.1,17.0,0.00416,-0.07518,45.3,0.9561222093616286,8.040388490655392,2.146030086274987e-09,0.1706766978871375,33.80700271226559,19.05772180818055,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-125,WAAREE ENERGIES LIMITED,Multi-c-Si,0,125.0,111.0,0.9834,1.49,0.66,72.0,8.2,21.0,7.4,17.0,0.0042639999999999996,-0.07518,45.3,0.9463138666037795,8.230867469400325,1.7880604837454856e-09,0.16858392325240265,44.7846375526519,17.00498272927718,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-130,WAAREE ENERGIES LIMITED,Multi-c-Si,0,130.0,115.5,0.9834,1.49,0.66,72.0,8.6,21.0,7.7,17.0,0.004471999999999999,-0.07518,45.3,0.9508845168813539,8.637658297954303,2.0663380617502163e-09,0.15985580663838875,36.506168241756015,17.961918106000297,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-135,WAAREE ENERGIES LIMITED,Mono-c-Si,0,135.0,118.8,1.0057500000000001,1.49,0.675,36.0,8.57,21.0,7.94,17.0,0.00350513,-0.07098,48.9,0.8847729816648273,8.58692989392183,4.109636409141989e-10,0.1758637223313591,89.02313692675926,9.70040532305742,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-140,WAAREE ENERGIES LIMITED,Mono-c-Si,0,140.0,123.4,1.0057500000000001,1.49,0.675,36.0,8.89,21.0,8.24,17.0,0.0036360100000000003,-0.07098,48.9,0.8845656432292466,8.907220806293873,4.2416116491254646e-10,0.1695544824640541,87.53013583577392,9.654155960742825,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-140,WAAREE ENERGIES LIMITED,Multi-c-Si,0,140.0,124.7,0.9834,1.49,0.66,36.0,9.3,21.0,8.3,17.0,0.004836000000000001,-0.07518,45.3,0.9527813331611625,9.34301824584821,2.3257669488662085e-09,0.14746763471868135,31.880640606182403,18.358857641465764,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-145,WAAREE ENERGIES LIMITED,Mono-c-Si,0,145.0,127.9,1.0057500000000001,1.49,0.675,36.0,9.21,21.0,8.53,17.0,0.0037668900000000006,-0.07098,48.9,0.8849408428425403,9.228480024694306,4.4346290871099414e-10,0.16362645078452237,81.5474978539976,9.737849767702055,-0.465,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-175,WAAREE ENERGIES LIMITED,Multi-c-Si,0,175.0,155.1,1.4751,1.49,0.99,72.0,7.6,32.0,6.8,26.0,0.003952,-0.11456,45.3,1.4529781404839386,7.63169059427618,1.93837257323701e-09,0.2586352614937371,62.02560655915701,18.54303510479675,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-180,WAAREE ENERGIES LIMITED,Multi-c-Si,0,180.0,159.7,1.4751,1.49,0.99,72.0,7.8,32.0,6.9,26.0,0.004056,-0.11456,45.3,1.4634350408971493,7.838728065088914,2.296070584359035e-09,0.24935302870744178,50.2207879406001,19.97904895629321,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-190,WAAREE ENERGIES LIMITED,Multi-c-Si,0,190.0,168.8,1.4751,1.49,0.99,54.0,8.3,32.0,7.3,26.0,0.004316,-0.11456,45.3,1.4688934982048532,8.344460018663453,2.631213943040115e-09,0.23295540164494588,43.489188810839515,20.72807540973905,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-200,WAAREE ENERGIES LIMITED,Multi-c-Si,0,200.0,177.9,1.4751,1.49,0.99,54.0,8.7,32.0,7.7,26.0,0.004523999999999999,-0.11456,45.3,1.4629679047682806,8.742898661056227,2.544751044285573e-09,0.22366796941938574,45.36066178067623,19.914929613591795,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-210,WAAREE ENERGIES LIMITED,Multi-c-Si,0,210.0,186.4,1.657014,1.662,0.997,72.0,8.0,36.0,7.3,29.0,0.00416,-0.12888,45.3,1.6066488326499746,8.024625810394909,1.426214998874381e-09,0.321744329869523,104.5226609191984,15.05951905513134,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-220,WAAREE ENERGIES LIMITED,Multi-c-Si,0,220.0,192.0,1.6434,1.66,0.99,60.0,8.14,36.0,7.6,29.0,0.005128200000000001,-0.12924,48.8,1.584757007662001,8.148276075538273,1.0947044167756839e-09,0.31922363651655944,313.975122193894,11.934035660054551,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-220,WAAREE ENERGIES LIMITED,Multi-c-Si,0,220.0,195.6,1.657014,1.662,0.997,72.0,8.3,36.0,7.6,29.0,0.004316,-0.12888,45.3,1.603419282218565,8.323005903269296,1.4203508539751591e-09,0.310582350368772,112.05098582958189,14.664754296238732,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-225,WAAREE ENERGIES LIMITED,Multi-c-Si,0,225.0,196.5,1.6434,1.66,0.99,60.0,8.33,36.0,7.76,29.0,0.0052479,-0.12924,48.8,1.5867194040140806,8.340180272590567,1.1490801951019517e-09,0.311728022075365,255.07132683851802,12.173461651145235,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-230,WAAREE ENERGIES LIMITED,Multi-c-Si,0,230.0,201.0,1.6434,1.66,0.99,60.0,8.51,36.0,7.94,29.0,0.005361299999999999,-0.12924,48.8,1.5853574974475269,8.519188970287182,1.1534017105326395e-09,0.30528090036415967,282.7239325634609,12.007303987476812,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-230,WAAREE ENERGIES LIMITED,Multi-c-Si,0,230.0,204.7,1.657014,1.662,0.997,72.0,8.7,36.0,7.9,29.0,0.004523999999999999,-0.12888,45.3,1.6112749677519715,8.73051986822471,1.6442598587372687e-09,0.2951866205916935,84.14597764362638,15.624798126065262,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-235,WAAREE ENERGIES LIMITED,Multi-c-Si,0,235.0,205.5,1.6434,1.66,0.99,60.0,8.7,36.0,8.11,29.0,0.005481,-0.12924,48.8,1.5861415286718967,8.710109629515436,1.1911793083871906e-09,0.29853205236507036,256.906558160403,12.102946332153634,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-240,WAAREE ENERGIES LIMITED,Multi-c-Si,0,240.0,210.0,1.6434,1.66,0.99,60.0,8.88,36.0,8.28,29.0,0.0055944,-0.12924,48.8,1.5859093608162773,8.89010170215732,1.2121797019604546e-09,0.29250440738429634,257.1289857238917,12.07463571599514,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WU-240,WAAREE ENERGIES LIMITED,Multi-c-Si,0,240.0,213.8,1.657014,1.662,0.997,72.0,9.0,36.0,8.3,29.0,0.004679999999999999,-0.12888,45.3,1.5968628695668878,9.019200201841576,1.416694311604801e-09,0.2872462039462404,134.64528284271807,13.862990272602806,-0.506,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-250,WAAREE ENERGIES LIMITED,Multi-c-Si,0,250.0,226.2,1.62,,,60.0,8.9,37.1,8.05,31.15,0.0042453000000000005,-0.1368619,46.0,1.5850808810818042,8.918128358564514,5.733283543558629e-10,0.14116601697347458,69.30454267002044,2.909781679552332,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-255,WAAREE ENERGIES LIMITED,Multi-c-Si,0,255.0,230.9,1.62,1.96,0.99,60.0,9.0,37.5,8.15,31.3,0.004293,-0.1383375,46.0,1.5952124570730695,9.021310062473823,5.245579689893518e-10,0.1684280439945683,71.13317746702977,2.0744007046080526,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-260,WAAREE ENERGIES LIMITED,Multi-c-Si,0,260.0,235.5,1.62,1.96,0.99,60.0,9.1,37.8,8.3,31.35,0.004340699999999999,-0.1394442,46.0,1.594824204608059,9.121616562908049,4.410274391027177e-10,0.19840073811203726,83.52145537333247,0.5389628937522686,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-265,WAAREE ENERGIES LIMITED,Multi-c-Si,0,265.0,240.2,1.62,1.96,0.99,60.0,9.15,37.9,8.45,31.45,0.004364550000000001,-0.1398131,46.0,1.5879804910472732,9.165212402641282,3.815869491541808e-10,0.1981869840443164,119.20608754419273,-0.7129007384510774,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-265,WAAREE ENERGIES LIMITED,Mono-c-Si,0,265.0,242.5,1.62,,,60.0,8.8,39.0,8.4,31.55,0.005544,-0.12164100000000001,45.8,1.5423195886467145,8.80000281072603,9.17603903262526e-11,0.3193464115986663,999999.3751912354,4.8375919798270814,-0.3974,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WS-270,WAAREE ENERGIES LIMITED,Multi-c-Si,0,270.0,244.9,1.62,1.96,0.99,60.0,9.2,38.0,8.55,31.6,0.0043884,-0.140182,46.0,1.5884237160201666,9.21150132101464,3.6533823778737563e-10,0.1896988383396835,151.741649623806,-1.124540054844892,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-270,WAAREE ENERGIES LIMITED,Mono-c-Si,0,270.0,247.3,1.62,,,60.0,8.95,39.1,8.5,31.8,0.004591349999999999,-0.12191380000000002,45.4,1.5393623716187435,8.950040129886824,8.330346904312721e-11,0.3171311339342007,70729.20490620578,4.058767490724741,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-270,WAAREE ENERGIES LIMITED,Mono-c-Si,0,270.0,247.2,1.62,,,60.0,8.95,39.1,8.5,31.8,0.005638499999999999,-0.1219529,45.8,1.5464356755834108,8.950002957810458,9.35711293367373e-11,0.3153817184287241,954466.5082481395,4.859942627879412,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-275,WAAREE ENERGIES LIMITED,Multi-c-Si,0,275.0,249.5,1.62,1.96,0.99,60.0,9.25,38.15,8.65,31.8,0.0044122499999999995,-0.14073535,46.0,1.5913184091249883,9.258030074995691,3.516579097906381e-10,0.1804653184573774,207.88153687465112,-1.4916608909290423,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-275,WAAREE ENERGIES LIMITED,Mono-c-Si,0,275.0,252.0,1.62,1.96,0.99,60.0,9.1,39.2,8.6,32.0,0.004668299999999999,-0.12222560000000002,45.4,1.5502438734350386,9.10421150763299,9.431776061205857e-11,0.29644609286340806,640.5448982920825,4.985007191038635,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-275,WAAREE ENERGIES LIMITED,Mono-c-Si,0,275.0,251.9,1.62,,,60.0,9.1,39.2,8.6,32.0,0.005733,-0.1222648,45.8,1.557169318129482,9.104029115085016,1.0556901304119796e-10,0.29474093479068153,665.6902998761105,5.763566088785996,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-280,WAAREE ENERGIES LIMITED,Multi-c-Si,0,280.0,254.2,1.62,1.96,0.99,60.0,9.35,38.3,8.75,32.0,0.00445995,-0.14128870000000002,46.0,1.5991017188629166,9.357395063850289,3.639219421063286e-10,0.16933890099551285,214.10482561960362,-1.3063572454786683,-0.4333,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-280,WAAREE ENERGIES LIMITED,Mono-c-Si,0,280.0,256.7,1.62,1.96,0.99,60.0,9.25,39.3,8.75,32.1,0.0047452499999999995,-0.12253739999999999,45.4,1.5539456710300295,9.253534629467067,9.557918671446732e-11,0.2899841647531135,758.878372960471,4.955691965873137,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-280,WAAREE ENERGIES LIMITED,Mono-c-Si,0,280.0,256.6,1.62,,,60.0,9.25,39.3,8.75,32.1,0.0058275,-0.1225767,45.8,1.5608885531322148,9.253354703545414,1.069844633811351e-10,0.288303626317841,794.9461494148879,5.734408453101192,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-285,WAAREE ENERGIES LIMITED,Multi-c-Si,0,285.0,249.5,1.9404,1.96,0.99,72.0,8.83,43.0,8.14,35.0,0.0055629,-0.15436999999999998,48.8,1.9185623101585405,8.846805009901344,1.582588497210171e-09,0.2969708876930899,156.0399949465346,14.633486184154888,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-285,WAAREE ENERGIES LIMITED,Mono-c-Si,0,285.0,261.4,1.62,1.96,0.99,60.0,9.35,39.4,8.85,32.25,0.00479655,-0.12284920000000002,45.4,1.559223474926963,9.35312907447703,9.875790343907259e-11,0.27864491320156637,832.6200964857471,5.140057366133142,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-285,WAAREE ENERGIES LIMITED,Mono-c-Si,0,285.0,261.3,1.62,,,60.0,9.35,39.4,8.85,32.25,0.0058905,-0.12288860000000001,45.8,1.566198118799119,9.35295481299157,1.1054642352577331e-10,0.2769733017989035,876.4346922820195,5.920911248084593,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-290,WAAREE ENERGIES LIMITED,Multi-c-Si,0,290.0,254.0,1.9404,1.96,0.99,72.0,8.99,43.0,8.27,35.0,0.005663700000000001,-0.15436999999999998,48.8,1.9209080453700518,9.008527593678375,1.6517476109802664e-09,0.2912701735990936,141.33079476427875,14.873123879330512,-0.496,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-290,WAAREE ENERGIES LIMITED,Mono-c-Si,0,290.0,266.1,1.62,1.96,0.99,60.0,9.45,39.5,8.95,32.45,0.00484785,-0.12316100000000002,45.4,1.5658205328336812,9.452777528616952,1.0419076470363657e-10,0.2610512197940513,888.1760449576678,5.503302370131018,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-290,WAAREE ENERGIES LIMITED,Mono-c-Si,0,290.0,266.0,1.62,,,60.0,9.45,39.5,8.95,32.45,0.0059535000000000005,-0.1232005,45.8,1.572838792098221,9.452612515836774,1.1663184843617158e-10,0.2593835934333603,938.2432518853933,6.287983093890871,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-295,WAAREE ENERGIES LIMITED,Mono-c-Si,0,295.0,270.9,1.61,1.96,0.99,60.0,9.55,39.6,9.05,32.6,0.0048991500000000006,-0.12347280000000001,45.4,1.5711018558350105,9.55241960615854,1.0759453742064643e-10,0.2502872567884695,987.8647701121014,5.685747897931503,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-295,WAAREE ENERGIES LIMITED,Mono-c-Si,0,295.0,270.7,1.62,,,60.0,9.55,39.6,9.05,32.6,0.006016500000000001,-0.12351240000000001,45.8,1.5781510736442197,9.55226033718382,1.2044460378957207e-10,0.24862841088101512,1050.4635255301012,6.47243055355516,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-300,WAAREE ENERGIES LIMITED,Multi-c-Si,0,300.0,270.2,1.92,,,72.0,8.65,46.1,8.1,37.05,0.0058474,-0.1703856,46.1,1.953540874177564,8.658267406875655,4.82521579807013e-10,0.4151130025046971,434.3234381847274,1.1510780356140613,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-300,WAAREE ENERGIES LIMITED,Mono-c-Si,0,300.0,275.6,1.61,1.96,0.99,60.0,9.7,39.7,9.2,32.7,0.004976099999999999,-0.12378460000000001,45.4,1.57484994146365,9.701849390573583,1.0900520122109731e-10,0.24487793749701034,1284.3779567910437,5.660812534088088,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-300,WAAREE ENERGIES LIMITED,Mono-c-Si,0,300.0,275.4,1.62,,,60.0,9.7,39.7,9.2,32.7,0.006110999999999999,-0.12382430000000001,45.8,1.5819168372582566,9.701692841071857,1.2202736086471987e-10,0.2432416857916161,1393.7781545494047,6.447649401289926,-0.3974,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-305,WAAREE ENERGIES LIMITED,Multi-c-Si,0,305.0,274.8,1.92,,,72.0,8.8,46.2,8.2,37.2,0.0059488,-0.1707552,46.1,1.965250426882768,8.812534366860643,5.336959513769868e-10,0.39851412932623703,279.7847802882492,1.8545607758315312,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-305,WAAREE ENERGIES LIMITED,Mono-c-Si,0,305.0,280.3,1.61,1.96,0.99,60.0,9.8,39.8,9.3,32.8,0.0050274000000000004,-0.1240964,45.4,1.5788344998382555,9.801482396608446,1.1022595631111326e-10,0.24083255970365877,1592.124319929604,5.666328528462093,-0.4035,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiH-2-310,WAAREE ENERGIES LIMITED,a-Si/nc,1,310.0,291.7,1.71,,,60.0,8.89,44.3,8.34,37.21,0.00235585,-0.104991,45.35,1.5039297498145192,8.902986605359441,1.3967464839387785e-12,0.27187942720188774,186.1154660485932,-1.2145964841813355,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-310,WAAREE ENERGIES LIMITED,Multi-c-Si,0,310.0,279.4,1.92,,,72.0,8.9,46.3,8.3,37.35,0.0060164,-0.1711248,46.1,1.9708212850289162,8.911802532305868,5.487247722152648e-10,0.3850165113089961,290.3315669046548,1.9887721629772348,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-310,WAAREE ENERGIES LIMITED,Mono-c-Si,0,310.0,289.5,1.65,1.96,0.99,60.0,9.9,39.9,9.43,32.9,0.0029007,-0.0980742,45.19,1.4125565684946804,9.902644309626606,5.329502772190673e-12,0.2758823998714133,1032.8729146438932,5.244247491943154,-0.3323,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiH-2-315,WAAREE ENERGIES LIMITED,a-Si/nc,1,315.0,296.5,1.71,,,60.0,8.98,44.4,8.42,37.45,0.0023797000000000002,-0.105228,45.35,1.5106193952180087,8.992492471912108,1.503037692468299e-12,0.24870960659686814,178.78065156699896,-0.6913392623510358,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-315,WAAREE ENERGIES LIMITED,Multi-c-Si,0,315.0,284.1,1.92,,,72.0,9.0,46.4,8.4,37.5,0.006083999999999999,-0.1714944,46.1,1.9764020676400746,9.01109759395213,5.641108146364174e-10,0.3718387046583558,301.5562752761399,2.123282422521686,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-315,WAAREE ENERGIES LIMITED,Mono-c-Si,0,315.0,289.8,1.61,1.96,0.99,60.0,10.0,40.0,9.55,33.0,0.00513,-0.12472000000000001,45.4,1.5890278746532005,10.000002170149946,1.168602983335966e-10,0.21698083150913758,999999.8260907069,5.984453454861893,-0.4035,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiH-2-320,WAAREE ENERGIES LIMITED,a-Si/nc,1,320.0,301.3,1.71,,,60.0,9.06,44.5,8.5,37.7,0.0024009,-0.105465,45.35,1.5167248864526113,9.07129554560072,1.598475753234595e-12,0.22504871049971578,180.5084402098536,-0.2583281494574804,-0.2901,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-320,WAAREE ENERGIES LIMITED,Multi-c-Si,0,320.0,288.7,1.92,,,72.0,9.15,46.5,8.5,37.65,0.006185400000000001,-0.171864,46.1,1.9880230016728035,9.164900921037205,6.219578345082189e-10,0.3563703713184628,218.8314034127128,2.8122258021638142,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-320,WAAREE ENERGIES LIMITED,Mono-c-Si,0,320.0,299.0,1.65,,,60.0,10.1,40.1,9.67,33.1,0.0029592999999999998,-0.0985658,45.19,1.4194298634731846,10.100002631524186,5.434531914183679e-12,0.2605437649455764,999998.9183041479,5.225169103592091,-0.3323,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WS-325,WAAREE ENERGIES LIMITED,Multi-c-Si,0,325.0,293.4,1.92,,,72.0,9.2,46.6,8.6,37.8,0.006219199999999999,-0.17223360000000001,46.1,1.9875917397313407,9.20976607854768,5.959755449960036e-10,0.3463983858890514,326.319915067196,2.393044273532057,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-325,WAAREE ENERGIES LIMITED,Mono-c-Si,0,325.0,303.8,1.65,,,60.0,10.2,40.2,9.79,33.2,0.0029885999999999997,-0.0988116,45.19,1.4247028485454714,10.200002522365802,5.680248226170191e-12,0.2472845218196181,999985.7309549886,5.52081550820268,-0.3323,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WS-330,WAAREE ENERGIES LIMITED,Multi-c-Si,0,330.0,298.0,1.92,,,72.0,9.25,46.7,8.7,37.95,0.006252999999999999,-0.1726032,46.1,1.9873146498140035,9.254900785039741,5.720081447198875e-10,0.33659456752006933,635.3066086099375,1.9892598261042769,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-330,WAAREE ENERGIES LIMITED,Mono-c-Si,0,330.0,301.8,1.92,,,72.0,9.35,46.9,8.76,37.7,0.005955950000000001,-0.1506428,45.3,1.8918021025829328,9.361254286730665,1.5785626532213315e-10,0.4121705173718331,342.4290599794795,5.848249385883641,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-330,WAAREE ENERGIES LIMITED,Mono-c-Si,0,330.0,300.2,1.92,,,72.0,9.35,46.9,8.76,37.7,0.0055352000000000005,-0.15542659999999997,45.8,1.9131775295328488,9.360602010779502,2.083638777843396e-10,0.4071095937896761,359.0333102358327,4.941912988417032,-0.4278,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-335,WAAREE ENERGIES LIMITED,Multi-c-Si,0,335.0,302.7,1.92,,,72.0,9.3,46.8,8.8,38.1,0.0062868,-0.17297279999999998,46.1,1.9871837944262367,9.300298189863414,5.498564720850979e-10,0.32695645871646173,10197.219709573346,1.6000840130540608,-0.4526,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-335,WAAREE ENERGIES LIMITED,Mono-c-Si,0,335.0,306.5,1.92,,,72.0,9.45,47.05,8.84,37.9,0.0060196500000000005,-0.1511246,45.3,1.9016200448339546,9.462745116366785,1.672270897035916e-10,0.39853411068974254,295.49730555838585,6.257300908427293,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-335,WAAREE ENERGIES LIMITED,Mono-c-Si,0,335.0,304.9,1.92,,,72.0,9.45,47.05,8.84,37.9,0.0055944,-0.15592369999999997,45.8,1.9231509564781541,9.462080553757492,2.207361466167626e-10,0.3934724860886094,307.79345636757563,5.347341963347449,-0.4278,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-340,WAAREE ENERGIES LIMITED,Multi-c-Si,0,340.0,309.6,1.92,,,72.0,9.35,46.9,8.9,38.25,0.005162883,-0.16023384999999998,45.3,1.9375598338800684,9.350002912654459,2.8734645914641267e-10,0.31140597406803927,999999.8916770768,4.454325040166477,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSM-340,WAAREE ENERGIES LIMITED,Mono-c-Si,0,340.0,311.3,1.92,,,72.0,9.5,47.15,8.93,38.1,0.0060515000000000005,-0.1514458,45.3,1.904283743475421,9.508043835121951,1.6602376310283436e-10,0.3816519492511041,450.7419521063774,6.134223129016249,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-340,WAAREE ENERGIES LIMITED,Mono-c-Si,0,340.0,309.6,1.92,,,72.0,9.5,47.15,8.93,38.1,0.0056240000000000005,-0.15625509999999998,45.8,1.9258228183920103,9.50745414463442,2.1913111512219076e-10,0.37663233107209904,480.00244959665207,5.224679275841184,-0.4278,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-345,WAAREE ENERGIES LIMITED,Multi-c-Si,0,345.0,314.3,1.92,,,72.0,9.4,47.0,8.95,38.55,0.0051904920000000005,-0.1605755,45.3,1.9471812848852545,9.400002660212326,3.092875470952816e-10,0.2828978450197144,999999.1709747127,5.0311718804607946,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSM-345,WAAREE ENERGIES LIMITED,Mono-c-Si,0,345.0,316.0,1.92,,,72.0,9.55,47.25,9.01,38.3,0.006083350000000001,-0.151767,45.3,1.9080769541131277,9.55471569257886,1.6703310596806795e-10,0.3650471293581868,739.2765051983683,6.129230510425752,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-345,WAAREE ENERGIES LIMITED,Mono-c-Si,0,345.0,314.3,1.92,,,72.0,9.55,47.25,9.01,38.3,0.005653600000000001,-0.1565865,45.8,1.9296515512162018,9.55418645779705,2.2045091085476015e-10,0.3600557065490408,821.3465946346065,5.219200897161344,-0.4278,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WS-350,WAAREE ENERGIES LIMITED,Multi-c-Si,0,350.0,319.0,1.92,,,72.0,9.45,47.1,9.0,38.9,0.005218101,-0.16091715,45.3,1.957996868345451,9.450002351515886,3.3759073651326017e-10,0.24874167782473292,999999.9418387699,5.7307985854247265,-0.43841,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSM-350,WAAREE ENERGIES LIMITED,Mono-c-Si,0,350.0,320.7,1.92,,,72.0,9.6,47.35,9.1,38.5,0.006115200000000001,-0.1520882,45.3,1.910823011400301,9.600714490183401,1.6598664567406e-10,0.3487964836929779,4686.484704435454,6.014678086956936,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-350,WAAREE ENERGIES LIMITED,Mono-c-Si,0,350.0,319.0,1.92,,,72.0,9.6,47.35,9.1,38.5,0.0056832,-0.1569179,45.8,1.9318666620518583,9.60000851494998,2.1763062438277013e-10,0.34395665252150687,387761.69618714176,5.048680940322054,-0.4278,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-355,WAAREE ENERGIES LIMITED,Mono-c-Si,0,355.0,325.4,1.92,,,72.0,9.65,47.45,9.18,38.7,0.006147050000000001,-0.1524094,45.3,1.9192241881460486,9.650003101754933,1.7669812433352938e-10,0.3213500363271102,999999.9301390301,6.503731305644137,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMB-355,WAAREE ENERGIES LIMITED,Mono-c-Si,0,355.0,323.7,1.92,,,72.0,9.65,47.45,9.18,38.7,0.0057128000000000005,-0.1572493,45.8,1.9419507993915333,9.650003029731176,2.359881877758343e-10,0.3138684312393587,999999.929603183,5.693182554644402,-0.4278,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSM-360,WAAREE ENERGIES LIMITED,Mono-c-Si,0,360.0,330.1,1.92,,,72.0,9.7,47.65,9.26,38.9,0.0061789,-0.1530518,45.3,1.9309222559756734,9.700003161909654,1.8601277883756734e-10,0.3258893882408683,999996.1043942207,6.901901227986124,-0.4144,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMB-360,WAAREE ENERGIES LIMITED,Mono-c-Si,0,360.0,328.4,1.92,,,72.0,9.7,47.65,9.26,38.9,0.0057424,-0.15791209999999997,45.8,1.9542368388898654,9.70000283452959,2.4969062188608844e-10,0.2921354511760053,999999.7404619453,6.13151386158941,-0.4278,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSM-365,WAAREE ENERGIES LIMITED,Mono-c-Si,0,365.0,334.8,1.92,,,72.0,9.75,47.85,9.34,39.1,0.006210750000000001,-0.1536942,45.3,1.9434371689863374,9.750002705694424,1.977409461490519e-10,0.27744468809648204,999995.9244658295,7.3865122780645915,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSM-370,WAAREE ENERGIES LIMITED,Mono-c-Si,0,370.0,339.6,1.92,,,72.0,9.8,48.05,9.42,39.3,0.006242600000000001,-0.1543366,45.3,1.9562231407399029,9.800215145569869,2.1068433310124924e-10,0.2521744583130351,11486.71472222986,7.894569186971031,-0.4144,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiH-1-375,WAAREE ENERGIES LIMITED,a-Si/nc,1,375.0,357.1,2.03,,,72.0,8.92,53.16,8.4,44.65,0.00264924,-0.1214706,44.12,1.716619691455683,8.932707580414498,3.098508847856312e-13,0.3493575350247189,245.2291266403189,-9.771727094690114,-0.2514,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-375,WAAREE ENERGIES LIMITED,Mono-c-Si,0,375.0,348.2,1.92,,,72.0,9.85,48.25,9.5,39.5,0.007905117500000001,-0.14325425,44.8,1.898558856231294,9.850209607393328,9.038580966234218e-11,0.25227117438093266,11854.896301569443,8.835981560451906,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiH-1-380,WAAREE ENERGIES LIMITED,a-Si/nc,1,380.0,362.0,2.03,,,72.0,8.99,53.28,8.46,44.94,0.0026700300000000003,-0.12174480000000001,44.12,1.72422050058106,9.002412473198687,3.3350583892397247e-13,0.3222048111605862,233.3637257501063,-9.260633769930447,-0.2514,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-380,WAAREE ENERGIES LIMITED,Mono-c-Si,0,380.0,353.0,1.92,,,72.0,9.9,48.45,9.58,39.7,0.007945245000000002,-0.14384805,44.8,1.9101644687955268,9.900160015980582,9.547992585894394e-11,0.22736095001114454,14066.572683842796,9.275726702523857,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMD-380,WAAREE ENERGIES LIMITED,Mono-c-Si,0,380.0,353.6,2.0,,,72.0,10.16,48.14,9.73,39.07,0.00261112,-0.1138511,47.7,1.640272852024184,10.160004054240023,1.8233938760578652e-12,0.39903526206592893,999994.5784939295,-0.003975243501733659,-0.3117,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMDB-380,WAAREE ENERGIES LIMITED,Mono-c-Si,1,380.0,357.0,1.93,,,54.0,13.34,36.45,12.44,30.59,0.00422878,-0.09272880000000001,43.46,1.3292108294301315,13.36025739664294,1.595576292983188e-11,0.13487314582655208,88.81732441390085,8.565136669619596,-0.3382,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiH-1-385,WAAREE ENERGIES LIMITED,a-Si/nc,1,385.0,366.8,2.03,,,72.0,9.06,53.4,8.52,45.24,0.00269082,-0.12201900000000002,44.12,1.7319914435353858,9.071967877687586,3.5982318924821437e-13,0.29412344646148614,222.6592241106705,-8.728349695474941,-0.2514,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-385,WAAREE ENERGIES LIMITED,Mono-c-Si,0,385.0,357.7,1.92,,,72.0,9.95,48.65,9.65,39.9,0.0079853725,-0.14444184999999998,44.8,1.9209348861738653,9.950146670807648,9.968865130068386e-11,0.20789896650128015,14103.606068114472,9.613703899917482,-0.37078,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMD-385,WAAREE ENERGIES LIMITED,Mono-c-Si,0,385.0,358.3,2.0,,,72.0,10.22,48.45,9.8,39.32,0.0026265400000000006,-0.11458425,47.7,1.6516279120026507,10.220004210264115,1.8601716856381044e-12,0.39368393677856606,955632.6125272228,0.11253857382588422,-0.3117,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMDB-385,WAAREE ENERGIES LIMITED,Mono-c-Si,1,385.0,361.8,1.93,,,54.0,13.42,36.57,12.55,30.71,0.00425414,-0.09303408,43.46,1.3048236825506818,13.439270676556193,8.790618019831612e-12,0.13791237095873984,96.04146567000129,3.3723764187562257,-0.3382,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-390,WAAREE ENERGIES LIMITED,Mono-c-Si,0,390.0,364.6,1.97,,,72.0,10.0,48.85,9.73,40.1,0.00286,-0.11469980000000002,45.7,1.7153354265679264,10.000002672610423,4.285367895229908e-12,0.2624971991302982,982180.1237197733,8.1554694082251,-0.3245,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMD-390,WAAREE ENERGIES LIMITED,Mono-c-Si,0,390.0,363.1,2.0,,,72.0,10.29,48.76,9.87,39.56,0.00264453,-0.11531739999999999,47.7,1.6621942584181033,10.290004235692098,1.8728681333991835e-12,0.39341726228191304,955753.9808069149,0.1123420675665317,-0.3117,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMDB-390,WAAREE ENERGIES LIMITED,Mono-c-Si,1,390.0,366.6,1.93,,,54.0,13.5,36.69,12.67,30.82,0.0042795,-0.09333936000000001,43.46,1.3344083656689365,13.515171143973198,1.5121761354971284e-11,0.13208569404298884,117.53608539018482,7.959609530614191,-0.3382,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-395,WAAREE ENERGIES LIMITED,Mono-c-Si,0,395.0,369.4,1.97,,,72.0,10.05,49.05,9.81,40.3,0.0028743,-0.1151694,45.7,1.7251548115886948,10.05000239846274,4.510274877115288e-12,0.23514764826915024,985316.4782085815,8.564789524951005,-0.3245,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMD-395,WAAREE ENERGIES LIMITED,Mono-c-Si,0,395.0,367.9,2.0,,,72.0,10.35,49.07,9.93,39.81,0.00265995,-0.11605055,47.7,1.6728969573135086,10.350004250228308,1.8882538785627965e-12,0.39265516654307253,956183.2060818474,0.13194312971695912,-0.3117,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMDB-395,WAAREE ENERGIES LIMITED,Mono-c-Si,1,395.0,371.4,1.93,,,54.0,13.58,36.94,12.73,31.06,0.00430486,-0.09397536000000001,43.46,1.3449219302081623,13.59590296719334,1.563663927663048e-11,0.12940719633700482,110.50451838389611,8.207318337539643,-0.3382,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDi-395,WAAREE ENERGIES LIMITED,Mono-c-Si,0,395.0,368.3,1.98,,,66.0,11.24,45.0,10.47,37.77,0.0034619200000000003,-0.11574,45.1,1.6440477679675056,11.257685010578676,1.412690815543414e-11,0.19654006650473785,124.91427939413079,7.827054636290902,-0.3478,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-395,WAAREE ENERGIES LIMITED,Mono-c-Si,1,395.0,370.8,1.98,,,66.0,11.24,45.0,10.47,37.77,0.00334952,-0.11105999999999999,44.12,1.611939089988406,11.2588332243456,8.182687082613707e-12,0.203479862712004,121.44036613305677,7.536360021161222,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-400,WAAREE ENERGIES LIMITED,Mono-c-Si,0,400.0,374.2,1.97,,,72.0,10.1,49.25,9.88,40.5,0.0028886,-0.115639,45.7,1.734274993295452,10.100002188085346,4.690400368807821e-12,0.2138868129129411,987286.1886227367,8.868863712633129,-0.3245,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMD-400,WAAREE ENERGIES LIMITED,Mono-c-Si,0,400.0,372.7,2.0,,,72.0,10.42,49.39,9.99,40.07,0.00267794,-0.11680734999999999,47.7,1.6833458735375122,10.420004124163388,1.885830529875002e-12,0.39578121603977834,999974.9896227067,0.06551811605092317,-0.3117,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMDB-400,WAAREE ENERGIES LIMITED,Mono-c-Si,1,400.0,376.2,1.93,,,54.0,13.66,37.06,12.84,31.19,0.00433022,-0.09428064000000001,43.46,1.3481294244710313,13.673646376317544,1.54089355355346e-11,0.12670176656248286,126.82825800107014,8.014743154762687,-0.3382,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDi-400,WAAREE ENERGIES LIMITED,Mono-c-Si,0,400.0,373.1,1.98,,,66.0,11.32,45.22,10.54,38.0,0.0034865600000000005,-0.11630584,45.1,1.6696724354835233,11.33710975584509,1.8978183872529888e-11,0.18764485611347262,124.1478719209776,10.371104953047206,-0.3478,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-400,WAAREE ENERGIES LIMITED,Mono-c-Si,1,400.0,375.6,1.98,,,66.0,11.32,45.22,10.54,38.0,0.00337336,-0.11160295999999999,44.12,1.6325835103552753,11.338414476620265,1.0247719995422839e-11,0.19559075301644888,120.2362344211567,9.459737215607285,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSM-405,WAAREE ENERGIES LIMITED,Mono-c-Si,0,405.0,379.0,1.97,,,72.0,10.15,49.45,9.96,40.7,0.0029029000000000004,-0.11610860000000002,45.7,1.744139548148063,10.150002059092122,4.935238085202126e-12,0.20035031107608486,987602.6320680521,9.27855557857081,-0.3245,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED WSMD-405,WAAREE ENERGIES LIMITED,Mono-c-Si,0,405.0,377.4,2.0,,,72.0,10.49,49.71,10.05,40.33,0.0026959300000000005,-0.11756415,47.7,1.6938630702124353,10.490006071546876,1.885737651247074e-12,0.4099777303406127,708332.7161905221,0.009724935924713391,-0.3117,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDB-405,WAAREE ENERGIES LIMITED,Mono-c-Si,1,405.0,381.0,1.93,,,54.0,13.73,37.18,12.95,31.31,0.00435241,-0.09458592,43.46,1.3506712257085463,13.740976700283491,1.4982793521837074e-11,0.12507159120093592,156.4434586646743,7.70871626500513,-0.3382,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDi-405,WAAREE ENERGIES LIMITED,Mono-c-Si,0,405.0,377.9,1.98,,,66.0,11.4,45.44,10.61,38.22,0.0035112000000000003,-0.11687167999999999,45.1,1.6789370653934397,11.417168932133354,1.9456140187573742e-11,0.1833727394378027,121.75767323163319,10.532753913088776,-0.3478,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-405,WAAREE ENERGIES LIMITED,Mono-c-Si,1,405.0,380.4,1.98,,,66.0,11.4,45.44,10.61,38.22,0.0033972,-0.11214591999999998,44.12,1.641616040215518,11.418484512996086,1.0505563874631995e-11,0.1913216454193452,117.99427778718201,9.620634382942606,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDi-410,WAAREE ENERGIES LIMITED,Mono-c-Si,0,410.0,382.7,1.98,,,66.0,11.48,45.66,10.68,38.44,0.0035358400000000006,-0.11743751999999998,45.1,1.6882018621739237,11.497213311038498,1.994132924219778e-11,0.17915682932321733,119.48429888122793,10.69286369926651,-0.3478,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-410,WAAREE ENERGIES LIMITED,Mono-c-Si,1,410.0,385.2,1.98,,,66.0,11.48,45.66,10.68,38.44,0.00342104,-0.11268887999999998,44.12,1.6506487216232308,11.498539794329368,1.0767309400056899e-11,0.18710870992926323,115.85932158488718,9.780009115867362,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-415,WAAREE ENERGIES LIMITED,Mono-c-Si,1,415.0,393.1,1.93,,,54.0,13.62,38.77,12.84,32.32,0.00439926,-0.09235014000000001,43.7,1.3367808942129025,13.635958380547846,3.392896328894215e-12,0.17217421978790792,146.94554180227445,1.98223744555567,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDi-415,WAAREE ENERGIES LIMITED,Mono-c-Si,0,415.0,387.5,1.98,,,66.0,11.57,45.88,10.75,38.66,0.0035635600000000003,-0.11800336,45.1,1.6982071563088976,11.587770345594905,2.0672754025764655e-11,0.17471035882272481,113.75123805780348,10.952012670902903,-0.3478,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-415,WAAREE ENERGIES LIMITED,Mono-c-Si,1,415.0,390.1,1.98,,,66.0,11.57,45.88,10.75,38.66,0.0034478600000000005,-0.11323184,44.12,1.6603885462227737,11.589133578315867,1.1161889188222548e-11,0.1826738296294717,110.46215073262505,10.038052192174993,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-420,WAAREE ENERGIES LIMITED,Mono-c-Si,1,420.0,397.9,1.93,,,54.0,13.69,38.93,12.92,32.51,0.0044218700000000005,-0.09273126,43.7,1.3427414047065074,13.704619945369014,3.446994881050081e-12,0.16704880075361733,156.42316212569,2.067790385236196,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-420,WAAREE ENERGIES LIMITED,Mono-c-Si,1,420.0,391.0,2.15,,,72.0,11.04,49.01,10.35,40.61,0.0035328,-0.12012351,47.17,1.7303495990789515,11.057513741956697,5.395237696161684e-12,0.28638368898887556,180.52543764386536,4.756636332112691,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-425,WAAREE ENERGIES LIMITED,Mono-c-Si,1,425.0,394.8,2.21,,,72.0,11.11,49.19,10.42,40.81,0.0033996599999999997,-0.11594083,46.2,1.7809363544253596,11.125602457023566,1.0987555325188268e-11,0.27069740760574673,192.75478235866575,15.40818119402312,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-425,WAAREE ENERGIES LIMITED,Mono-c-Si,1,425.0,402.8,1.93,,,54.0,13.76,39.1,13.0,32.69,0.004444480000000001,-0.0931362,43.7,1.348690059474541,13.773439536053456,3.4749493629109725e-12,0.16363519184354275,167.53705138553354,2.088255207971054,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-425,WAAREE ENERGIES LIMITED,Mono-c-Si,1,425.0,395.8,2.15,,,72.0,11.11,49.19,10.42,40.81,0.0035551999999999997,-0.12056469,47.17,1.7374174410600778,11.126983923063092,5.494958753587092e-12,0.28006245424267495,183.20230586924959,4.85801909080467,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-31-430,WAAREE ENERGIES LIMITED,Mono-c-Si,1,430.0,402.4,2.157,,,72.0,11.19,49.39,10.49,41.01,0.00348009,-0.12540121,45.18,1.7652640401538158,11.206692736640658,7.722802431024583e-12,0.27123290318733806,181.82136690247793,4.009025200981739,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-430,WAAREE ENERGIES LIMITED,Mono-c-Si,1,430.0,399.5,2.21,,,72.0,11.19,49.39,10.49,41.01,0.00342414,-0.11641222999999999,46.2,1.7893111850444758,11.205934048530285,1.1254813712023965e-11,0.2660994975063387,186.87362290313303,15.569074357040881,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-430,WAAREE ENERGIES LIMITED,Mono-c-Si,1,430.0,407.6,1.93,,,54.0,13.83,39.26,13.08,32.87,0.004467090000000001,-0.09351732,43.7,1.354455774706015,13.84225961756742,3.5150253309581068e-12,0.15949583920724536,179.9262861852189,2.137615674698388,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-430,WAAREE ENERGIES LIMITED,Mono-c-Si,0,430.0,402.8,2.16,,,48.0,11.19,49.39,10.49,41.01,0.00332343,-0.1195238,44.83,1.761694109451944,11.206807008690967,7.296473636467059e-12,0.2719971884830044,181.09400669879327,8.664263832762767,-0.3298,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-430,WAAREE ENERGIES LIMITED,Mono-c-Si,1,430.0,400.5,2.15,,,72.0,11.19,49.39,10.49,41.01,0.0035808,-0.12105489000000001,47.17,1.7455752867639973,11.207328280066182,5.6299758563823655e-12,0.27545521763578623,177.8793901312939,5.00730023533449,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-31-435,WAAREE ENERGIES LIMITED,Mono-c-Si,1,435.0,407.2,2.157,,,72.0,11.25,49.59,10.56,41.21,0.00349875,-0.12590901000000002,45.18,1.7720404791611335,11.265514194357985,7.7299734361454e-12,0.2672789852142799,193.81532298435835,3.966007326638451,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-435,WAAREE ENERGIES LIMITED,Mono-c-Si,1,435.0,404.3,2.21,,,72.0,11.25,49.59,10.56,41.21,0.0034425,-0.11688363000000002,46.2,1.796179032555004,11.264778049987388,1.126601121463059e-11,0.26215865479154915,199.57197128862126,15.522051933963963,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-435,WAAREE ENERGIES LIMITED,Mono-c-Si,1,435.0,412.5,1.93,,,54.0,13.9,39.42,13.16,33.05,0.004489700000000001,-0.09389844000000001,43.7,1.3602213436811743,13.911127894944384,3.5552578930523375e-12,0.15540763267789773,194.1217171056886,2.1865215346084073,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-435,WAAREE ENERGIES LIMITED,Mono-c-Si,0,435.0,407.6,2.16,,,48.0,11.25,49.59,10.56,41.21,0.00334125,-0.12000780000000001,44.83,1.768459249198321,11.265625045858538,7.303439399887287e-12,0.2680408405719811,192.98882972983748,8.619465697209835,-0.3298,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-435,WAAREE ENERGIES LIMITED,Mono-c-Si,1,435.0,405.3,2.15,,,72.0,11.25,49.59,10.56,41.21,0.0036000000000000003,-0.12154509000000002,47.17,1.7522816806509953,11.266131098501365,5.635328974169582e-12,0.27148951961197876,189.3396844852959,4.963853784849787,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-31-440,WAAREE ENERGIES LIMITED,Mono-c-Si,1,440.0,412.0,2.157,,,72.0,11.34,49.69,10.63,41.41,0.00352674,-0.12616291000000002,45.18,1.7792374165852574,11.3561122921144,8.2334362983651e-12,0.2530151856615733,178.07473884907242,4.441300086235217,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-440,WAAREE ENERGIES LIMITED,Mono-c-Si,1,440.0,409.1,2.21,,,72.0,11.34,49.69,10.63,41.41,0.0034700399999999998,-0.11711933,46.2,1.8034596083011272,11.355370135199982,1.198788265045248e-11,0.24789873383291028,182.89830325587593,16.03910268798567,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-440,WAAREE ENERGIES LIMITED,Mono-c-Si,1,440.0,417.3,1.93,,,54.0,13.97,39.58,13.24,33.23,0.004512310000000001,-0.09427956,43.7,1.365986702909015,13.98004335146789,3.595641145141762e-12,0.1513696397490053,210.55062370641178,2.2349681814723215,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-440,WAAREE ENERGIES LIMITED,Mono-c-Si,0,440.0,412.4,2.16,,,48.0,11.34,49.69,10.63,41.41,0.00336798,-0.1202498,44.83,1.7756041635904893,11.35622528395757,7.77542424232583e-12,0.2537848569240444,177.37256759202472,9.112055688313875,-0.3298,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-440,WAAREE ENERGIES LIMITED,Mono-c-Si,1,440.0,410.1,2.15,,,72.0,11.34,49.69,10.63,41.41,0.0036288,-0.12179019,47.17,1.7593449236494048,11.356736301101172,6.001093310583151e-12,0.25723635926620625,174.29540140854965,5.443619639714952,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-31-445,WAAREE ENERGIES LIMITED,Mono-c-Si,1,445.0,416.8,2.157,,,72.0,11.41,49.89,10.7,41.61,0.00354851,-0.12667071000000002,45.18,1.7867569698338006,11.425698068087309,8.334155075601464e-12,0.24894330618911079,180.94220978403575,4.490843048055844,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-445,WAAREE ENERGIES LIMITED,Mono-c-Si,1,445.0,413.8,2.21,,,72.0,11.41,49.89,10.7,41.61,0.00349146,-0.11759073,46.2,1.7498010741998964,11.426850966113012,4.616976584047988e-12,0.2567516518060563,173.84975620621103,7.308964639205237,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-05-445,WAAREE ENERGIES LIMITED,Mono-c-Si,1,445.0,422.2,1.93,,,54.0,14.04,39.74,13.32,33.41,0.0045349200000000004,-0.09466068000000001,43.7,1.3717518778389184,14.049005058700729,3.6361755969535235e-12,0.14738093679305483,229.7851046293031,2.282965855936318,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-445,WAAREE ENERGIES LIMITED,Mono-c-Si,0,445.0,417.2,2.16,,,48.0,11.41,49.89,10.7,41.61,0.00338877,-0.1207338,44.83,1.7831039890814697,11.425810018716314,7.870089723982655e-12,0.24971245825746996,180.21599934185352,9.163304436012456,-0.3298,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-445,WAAREE ENERGIES LIMITED,Mono-c-Si,1,445.0,414.9,2.15,,,72.0,11.41,49.89,10.7,41.61,0.0036512000000000003,-0.12228039,47.17,1.766775142221903,11.426315807355905,6.0743779683422085e-12,0.25315776322546996,177.03874652359588,5.493615077227044,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-31-450,WAAREE ENERGIES LIMITED,Mono-c-Si,1,450.0,421.6,2.157,,,72.0,11.46,50.1,10.77,41.81,0.00356406,-0.1272039,45.18,1.7656404877941667,11.460007258130545,5.446107446434674e-12,0.2517313878058037,397464.69104412803,0.8007384131350094,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-450,WAAREE ENERGIES LIMITED,Mono-c-Si,1,450.0,418.6,2.21,,,72.0,11.46,50.1,10.77,41.81,0.0035067600000000003,-0.1180857,46.2,1.8173822796275583,11.47325200091426,1.1974421663165927e-11,0.24134665098965996,208.7105671442281,15.917107924975998,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-450,WAAREE ENERGIES LIMITED,Mono-c-Si,0,450.0,422.0,2.16,,,48.0,11.46,50.1,10.77,41.81,0.0034036200000000004,-0.121242,44.83,1.7620012879147822,11.460007106032538,5.136111679657267e-12,0.2524959483376164,407205.0405569938,5.294010839281647,-0.3298,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-450,WAAREE ENERGIES LIMITED,Mono-c-Si,1,450.0,419.7,2.15,,,72.0,11.46,50.1,10.77,41.81,0.0036672000000000002,-0.1227951,47.17,1.7457547732997638,11.460007340103138,3.941986458909813e-12,0.25591641617388244,399559.6451962262,1.6938535701897124,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-31-455,WAAREE ENERGIES LIMITED,Mono-c-Si,1,455.0,426.4,2.157,,,72.0,11.53,50.3,10.84,42.02,0.00358583,-0.1277117,45.18,1.7737116598776552,11.530006912132862,5.569759494743654e-12,0.24660627380783093,411360.6078944021,0.9356977398732736,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-33-455,WAAREE ENERGIES LIMITED,Mono-c-Si,1,455.0,423.4,2.21,,,72.0,11.53,50.3,10.84,42.02,0.0035281799999999997,-0.1185571,46.2,1.778260199412575,11.530006647153561,5.988791022786434e-12,0.24565712295719191,426112.7110847966,9.420458052325555,-0.3428,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-455,WAAREE ENERGIES LIMITED,Mono-c-Si,0,455.0,426.8,2.16,,,48.0,11.53,50.3,10.84,42.02,0.00342441,-0.121726,44.83,1.7700469628419115,11.530006801904012,5.252155312626072e-12,0.2473716432108018,419324.33497209306,5.434110685538557,-0.3298,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMDIB-455,WAAREE ENERGIES LIMITED,Mono-c-Si,1,455.0,424.5,2.15,,,72.0,11.53,50.3,10.84,42.02,0.0036896,-0.1232853,47.17,1.753718171225324,11.530007000910658,4.031126805332665e-12,0.25078912371614487,413032.7252561492,1.8298046698452033,-0.3198,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-465,WAAREE ENERGIES LIMITED,Mono-c-Si,1,465.0,439.9,2.14,,,60.0,13.64,43.02,12.86,36.16,0.0048422000000000005,-0.10290384000000001,44.5,1.4852892065196892,13.654269900500282,3.5284552125587154e-12,0.1651773981721475,157.8861543652357,1.8264263838550974,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-470,WAAREE ENERGIES LIMITED,Mono-c-Si,1,470.0,444.8,2.14,,,60.0,13.71,43.2,12.94,36.32,0.0048670499999999995,-0.1033344,44.5,1.490936224235703,13.72335926163343,3.5120328629691996e-12,0.1643242187303074,168.63843996999594,1.7393389487753224,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-475,WAAREE ENERGIES LIMITED,Mono-c-Si,1,475.0,449.6,2.14,,,60.0,13.78,43.44,13.02,36.48,0.004891899999999999,-0.10390848,44.5,1.4976837646400534,13.792717345407256,3.4312768731462274e-12,0.16810737974948237,182.15434284694058,1.496183371933512,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-480,WAAREE ENERGIES LIMITED,Mono-c-Si,1,480.0,454.5,2.14,,,60.0,13.85,43.62,13.1,36.64,0.00491675,-0.10433904,44.5,1.5033392169192636,13.861797801728088,3.4164189647958607e-12,0.16724379817850094,196.335441113558,1.4125888945061227,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-485,WAAREE ENERGIES LIMITED,Mono-c-Si,1,485.0,459.3,2.14,,,60.0,13.92,43.8,13.18,36.8,0.004941599999999999,-0.1047696,44.5,1.508998210489026,13.930886668469762,3.4019935457169906e-12,0.16638957621041003,212.75038457719626,1.3302153380456663,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-490,WAAREE ENERGIES LIMITED,Mono-c-Si,1,490.0,464.1,2.14,,,60.0,13.99,43.98,13.26,36.95,0.00496645,-0.10520015999999999,44.5,1.5144689642826434,14.000019830011992,3.375638375967871e-12,0.1664005727333506,232.3336835947035,1.2184176436097667,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-06-495,WAAREE ENERGIES LIMITED,Mono-c-Si,1,495.0,469.0,2.14,,,60.0,14.06,44.16,13.34,37.11,0.0049913,-0.10563072,44.5,1.520135215042473,14.069120251167082,3.3621544607988384e-12,0.16555933315424678,255.23027653652514,1.1385955873815419,-0.2958,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-515,WAAREE ENERGIES LIMITED,Mono-c-Si,1,515.0,487.8,2.34,,,66.0,13.69,47.39,12.9,39.92,0.00444925,-0.11373599999999999,43.8,1.6451462480143695,13.704047064745335,4.145253150881482e-12,0.17238141340698368,167.99962089052752,2.8564863660766444,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-520,WAAREE ENERGIES LIMITED,Mono-c-Si,1,520.0,479.8,2.56,,,72.0,13.55,49.01,12.65,41.14,0.0047967,-0.1347775,46.69,1.8698090375920708,13.566646394535448,5.458796470422155e-11,0.1630915438701061,132.75489976461242,10.6748098973123,-0.3709,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-57-520,WAAREE ENERGIES LIMITED,Mono-c-Si,1,520.0,487.6,2.55,,,72.0,13.55,49.01,12.65,41.14,0.0043631,-0.12218193,44.62,1.7715242931615045,13.570165295499487,1.2720596032750054e-11,0.18048822915313747,121.27843658145065,8.630199669811244,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-520,WAAREE ENERGIES LIMITED,Mono-c-Si,1,520.0,492.7,2.34,,,66.0,13.76,47.59,12.98,40.06,0.004472,-0.11421600000000001,43.8,1.6507130323930612,13.77338850368358,4.072977291991048e-12,0.17480691423706873,179.65735374803918,2.6592892082550468,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-520,WAAREE ENERGIES LIMITED,Mono-c-Si,0,520.0,484.8,2.55,,,72.0,13.55,49.01,12.65,41.14,0.0041192,-0.13041561,44.94,1.8210526494266808,13.568344320829016,2.7027563128738434e-11,0.17167798339912377,126.80963801177624,8.161801590103853,-0.3539,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-525,WAAREE ENERGIES LIMITED,Mono-c-Si,1,525.0,484.6,2.56,,,72.0,13.63,49.16,12.73,41.29,0.00482502,-0.13519,46.69,1.875704851634804,13.646244919206008,5.506733842823667e-11,0.16050674875293644,134.67022988367515,10.698665320740895,-0.3709,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-57-525,WAAREE ENERGIES LIMITED,Mono-c-Si,1,525.0,492.4,2.55,,,72.0,13.63,49.16,12.73,41.29,0.0043888600000000005,-0.12255587999999999,44.62,1.7771010802001472,13.649732096810153,1.2832198479120157e-11,0.17785581504568848,122.85439244676168,8.6536379009017,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-525,WAAREE ENERGIES LIMITED,Mono-c-Si,1,525.0,497.5,2.34,,,66.0,13.83,47.79,13.06,40.2,0.0044947500000000005,-0.11469599999999999,43.8,1.6562869030114191,13.842700544809322,4.002938621072039e-12,0.17720039446667166,192.9587663407196,2.4647423017204573,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-525,WAAREE ENERGIES LIMITED,Mono-c-Si,0,525.0,489.6,2.55,,,72.0,13.63,49.16,12.73,41.29,0.00414352,-0.13081476,44.94,1.8267904101253098,13.647926948222404,2.7264936137731108e-11,0.1690696505029303,128.54498816184656,8.185116467075797,-0.3539,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-530,WAAREE ENERGIES LIMITED,Mono-c-Si,1,530.0,489.3,2.56,,,72.0,13.69,49.31,12.8,41.45,0.00484626,-0.13560250000000001,46.69,1.8811858175468366,13.70526793472635,5.5190184810685457e-11,0.15738306927191828,141.1175958273843,10.674826045202892,-0.3709,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-57-530,WAAREE ENERGIES LIMITED,Mono-c-Si,1,530.0,497.2,2.55,,,72.0,13.69,49.31,12.8,41.45,0.004408179999999999,-0.12292983,44.62,1.7823055793528466,13.708655984901375,1.2860697129700025e-11,0.1746914540151847,128.19082050657613,8.629660673988903,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-530,WAAREE ENERGIES LIMITED,Mono-c-Si,1,530.0,502.4,2.34,,,66.0,13.9,47.99,13.14,40.33,0.004517500000000001,-0.115176,43.8,1.6616737003268942,13.912027890021877,3.921887819817585e-12,0.18042710875124146,208.5101219014989,2.2444962360262033,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-530,WAAREE ENERGIES LIMITED,Mono-c-Si,0,530.0,494.4,2.55,,,72.0,13.69,49.31,12.8,41.45,0.00416176,-0.13121391000000002,44.94,1.8321328318306707,13.706900941088747,2.7325001015417384e-11,0.1659261445317457,134.4025115316667,8.161336019957396,-0.3539,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-535,WAAREE ENERGIES LIMITED,Mono-c-Si,1,535.0,494.1,2.56,,,72.0,13.76,49.46,12.88,41.6,0.00487104,-0.13601500000000002,46.69,1.8863850873124588,13.77436865261835,5.514107937367726e-11,0.15508331876552822,148.51402836620127,10.616591577724487,-0.3709,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-57-535,WAAREE ENERGIES LIMITED,Mono-c-Si,1,535.0,502.0,2.55,,,72.0,13.76,49.46,12.88,41.6,0.00443072,-0.12330378,44.62,1.7872575336334116,13.777664267714297,1.284917775337627e-11,0.17232981638226214,134.24039526473047,8.571653176329736,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-535,WAAREE ENERGIES LIMITED,Mono-c-Si,1,535.0,507.2,2.34,,,66.0,13.97,48.18,13.22,40.47,0.004540250000000001,-0.115632,43.8,1.667078315821953,13.981244366005251,3.867151088348334e-12,0.18199355500746076,226.1087884374266,2.07888392269811,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-535,WAAREE ENERGIES LIMITED,Mono-c-Si,0,535.0,499.2,2.55,,,72.0,13.76,49.46,12.88,41.6,0.00418304,-0.13161306,44.94,1.8372072004519664,13.775955950637403,2.7299578530716038e-11,0.1635962414853356,141.0811767511254,8.103735519737995,-0.3539,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-540,WAAREE ENERGIES LIMITED,Mono-c-Si,1,540.0,498.9,2.56,,,72.0,13.83,49.61,12.95,41.75,0.00489582,-0.1364275,46.69,1.8923370860654012,13.844026957538283,5.561901344978679e-11,0.1526947495418884,150.5507297164263,10.646967054875466,-0.3709,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-57-540,WAAREE ENERGIES LIMITED,Mono-c-Si,1,540.0,506.8,2.55,,,72.0,13.83,49.61,12.95,41.75,0.0044532600000000006,-0.12367773,44.62,1.7928847352783335,13.847292587140624,1.2960442625482415e-11,0.1699098824430491,135.88791887499772,8.601568780949362,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-540,WAAREE ENERGIES LIMITED,Mono-c-Si,1,540.0,512.1,2.34,,,66.0,14.04,48.38,13.3,40.6,0.004563,-0.116112,43.8,1.672479484142903,14.05050387175594,3.790723754339385e-12,0.18514813099074773,247.478247247963,1.8640152934410177,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-540,WAAREE ENERGIES LIMITED,Mono-c-Si,0,540.0,504.0,2.55,,,72.0,13.83,49.61,12.95,41.75,0.00420432,-0.13201221,44.94,1.8429985005361589,13.84559922823804,2.753633194214388e-11,0.1611921163813459,142.9100816205819,8.133485847311949,-0.3539,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-545,WAAREE ENERGIES LIMITED,Mono-c-Si,1,545.0,503.6,2.56,,,72.0,13.9,49.76,13.02,41.9,0.004920600000000001,-0.13684000000000002,46.69,1.8982900623230559,13.913690895592508,5.60990692834132e-11,0.15033172853050095,152.62778330814663,10.677270399878685,-0.3709,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-57-545,WAAREE ENERGIES LIMITED,Mono-c-Si,1,545.0,511.6,2.55,,,72.0,13.9,49.76,13.02,41.9,0.0044758,-0.12405168,44.62,1.7985127623815786,13.916926546098066,1.307219080771695e-11,0.16751585867081648,137.56323503350933,8.631406687257186,-0.3315,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-07-545,WAAREE ENERGIES LIMITED,Mono-c-Si,1,545.0,516.9,2.34,,,66.0,14.11,48.58,13.38,40.73,0.00458575,-0.116592,43.8,1.6778878460221212,14.119725258511671,3.716752058430486e-12,0.18826281042923007,273.1432028643416,1.6519184028412122,-0.3019,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED WSMD-545,WAAREE ENERGIES LIMITED,Mono-c-Si,0,545.0,508.8,2.55,,,72.0,13.9,49.76,13.02,41.9,0.0042256,-0.13241136,44.94,1.8487906948800903,13.91524815240302,2.7774124067100827e-11,0.1588137203813874,144.77234131427252,8.163161451817652,-0.3539,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-55-550,WAAREE ENERGIES LIMITED,Mono-c-Si,1,550.0,508.4,2.56,,,72.0,13.96,49.91,13.08,42.03,0.00494184,-0.1372525,46.69,1.903817196340089,13.973523307717864,5.620880072196496e-11,0.14985521542093555,154.69431505319946,10.655017733567991,-0.3709,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-01-555,WAAREE ENERGIES LIMITED,Mono-c-Si,1,555.0,527.1,2.54,,,54.0,18.16,38.88,17.14,32.28,0.00637416,-0.09234,43.3,1.3305948642671221,18.18109021747488,3.645089590093594e-12,0.13915379791784996,119.82014769019311,0.42874466417260626,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-01-560,WAAREE ENERGIES LIMITED,Mono-c-Si,1,560.0,532.0,2.54,,,54.0,18.2,39.04,17.18,32.6,0.006388199999999999,-0.09272,43.3,1.3395991257176085,18.219561535694616,3.943918630908662e-12,0.1270367902297327,118.19468677742655,1.0686669719089452,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-01-565,WAAREE ENERGIES LIMITED,Mono-c-Si,1,565.0,536.8,2.54,,,54.0,18.24,39.2,17.22,32.81,0.006402239999999999,-0.0931,43.3,1.3464801787483005,18.258844494326798,4.07314973097666e-12,0.12224062959862783,118.3193906530004,1.3202761304061836,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-08-565,WAAREE ENERGIES LIMITED,Mono-c-Si,1,565.0,536.1,2.56,,,72.0,13.75,51.9,12.97,43.56,0.004510000000000001,-0.1237815,43.2,1.7990528476344967,13.764009739136924,3.996183024741919e-12,0.20176392085215472,198.0232384279289,3.1470696635039555,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-01-570,WAAREE ENERGIES LIMITED,Mono-c-Si,1,570.0,541.7,2.54,,,54.0,18.29,39.31,17.26,33.02,0.00641979,-0.09336124999999999,43.3,1.352780365289897,18.30844131954278,4.30862949198371e-12,0.11447593589355179,113.53660807439958,1.772096560203426,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-08-570,WAAREE ENERGIES LIMITED,Mono-c-Si,1,570.0,541.0,2.56,,,72.0,13.81,52.1,13.04,43.71,0.00452968,-0.1242585,43.2,1.8047918429293575,13.823234987342001,3.94263419873481e-12,0.20328984166810463,212.12205522479715,2.990644451976372,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-01-575,WAAREE ENERGIES LIMITED,Mono-c-Si,1,575.0,546.6,2.54,,,54.0,18.34,39.47,17.31,33.22,0.00643734,-0.09374125,43.3,1.3594462216221164,18.357746142505647,4.42891901713455e-12,0.11033220402445999,114.02436461316435,1.9807420620850513,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-08-575,WAAREE ENERGIES LIMITED,Mono-c-Si,1,575.0,545.9,2.56,,,72.0,13.87,52.3,13.11,43.86,0.00454936,-0.1247355,43.2,1.8105363977187094,13.88244408837257,3.890497578620052e-12,0.2047976112004567,228.2644405945329,2.8361331675427075,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-66-580,WAAREE ENERGIES LIMITED,Mono-c-Si,1,580.0,537.2,2.81,,,60.0,17.73,41.56,16.96,34.21,0.011347200000000002,-0.11079896,45.96,1.5918245307427232,17.730002464293143,8.127770441179859e-11,0.13897286308011014,999998.6732443945,14.910632307052898,-0.3686,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-01-580,WAAREE ENERGIES LIMITED,Mono-c-Si,1,580.0,551.4,2.54,,,54.0,18.39,39.58,17.35,33.43,0.0064548900000000005,-0.09400249999999999,43.3,1.3657464199373266,18.40720545820793,4.680846237428711e-12,0.10263939751443273,109.70579795150982,2.4276733333564957,-0.2944,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-08-580,WAAREE ENERGIES LIMITED,Mono-c-Si,1,580.0,550.7,2.56,,,72.0,13.93,52.5,13.18,44.01,0.004569040000000001,-0.1252125,43.2,1.8162864080460197,13.941637277752118,3.839724001865559e-12,0.20628755383306496,246.9293670049724,2.6835012012733963,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-66-585,WAAREE ENERGIES LIMITED,Mono-c-Si,1,585.0,542.0,2.81,,,60.0,17.78,41.76,17.04,34.34,0.0113792,-0.11133216,45.96,1.6001058331222202,17.78000243452168,8.233690461201529e-11,0.13690763648323798,999996.188532925,15.004960828744121,-0.3686,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-08-585,WAAREE ENERGIES LIMITED,Mono-c-Si,1,585.0,555.6,2.56,,,72.0,13.99,52.7,13.25,44.15,0.00458872,-0.1256895,43.2,1.8218482660465178,14.00084557443027,3.778717069473789e-12,0.20861754089487294,269.1014127885089,2.506851511581338,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-66-590,WAAREE ENERGIES LIMITED,Mono-c-Si,1,590.0,546.8,2.81,,,60.0,17.84,41.9,17.16,34.39,0.0114176,-0.1117054,45.96,1.6069768550926498,17.840212720655618,8.464436579852203e-11,0.13128096261401823,11010.004580767358,15.231971229711329,-0.3686,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-08-590,WAAREE ENERGIES LIMITED,Mono-c-Si,1,590.0,560.4,2.56,,,72.0,14.05,52.9,13.32,44.29,0.004608400000000001,-0.1261665,43.2,1.8274161226472958,14.06002957208498,3.719408133504908e-12,0.21092113517647632,295.4704279242351,2.3323069652996353,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-66-595,WAAREE ENERGIES LIMITED,Mono-c-Si,1,595.0,551.5,2.81,,,60.0,17.9,42.05,17.29,34.44,0.011456,-0.11210529999999999,45.96,1.6139956454654598,17.900002756676372,8.670096568142048e-11,0.12469891762791348,809692.4142805564,15.424067346395443,-0.3686,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-08-595,WAAREE ENERGIES LIMITED,Mono-c-Si,1,595.0,565.3,2.56,,,72.0,14.11,53.1,13.39,44.44,0.0046280800000000006,-0.1266435,43.2,1.8331825450638504,14.119167688994564,3.672827616633261e-12,0.21235036755295683,326.8286799120836,2.1853881134917312,-0.3024,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-66-600,WAAREE ENERGIES LIMITED,Mono-c-Si,1,600.0,556.3,2.81,,,60.0,17.98,42.18,17.35,34.62,0.0115072,-0.11245188,45.96,1.619752749393702,17.980002728744367,8.817000992523744e-11,0.12286021332308636,809521.6823823287,15.539481485867526,-0.3686,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-600,WAAREE ENERGIES LIMITED,Mono-c-Si,1,600.0,570.9,2.7,,,44.0,15.82,48.3,14.8,40.54,0.006296360000000001,-0.1128771,43.2,1.6626925357614715,15.845277435895234,3.723749651074039e-12,0.16537243749368766,103.49910233932029,3.400511940523925,-0.2879,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-66-605,WAAREE ENERGIES LIMITED,Mono-c-Si,1,605.0,561.1,2.81,,,60.0,18.03,42.35,17.46,34.68,0.011539200000000001,-0.11290510000000001,45.96,1.6272479109717073,18.030002608198966,8.979406131464156e-11,0.11736051913057384,811268.3183725422,15.684342639418578,-0.3686,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-605,WAAREE ENERGIES LIMITED,Mono-c-Si,1,605.0,575.8,2.7,,,44.0,15.87,48.5,14.85,40.74,0.006316260000000001,-0.11334449999999999,43.2,1.67003348792251,15.894800973254373,3.765967156484158e-12,0.16308740186267864,104.35868679575736,3.46923925113119,-0.2879,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-610,WAAREE ENERGIES LIMITED,Mono-c-Si,1,610.0,580.6,2.7,,,44.0,15.92,48.7,14.9,40.94,0.00633616,-0.11381190000000001,43.2,1.6773739834844243,15.944331244884763,3.808326201268462e-12,0.1608181194526377,105.2237323335548,3.5373357268934864,-0.2879,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-17-615,WAAREE ENERGIES LIMITED,Mono-c-Si,1,615.0,582.0,2.77,,,78.0,13.78,56.55,13.01,47.27,0.004588740000000001,-0.13860405,43.8,1.9736262619198155,13.793497960406386,4.879300473260668e-12,0.23313753934880363,238.00894362690178,1.9832207955405576,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-615,WAAREE ENERGIES LIMITED,Mono-c-Si,1,615.0,585.5,2.7,,,44.0,15.97,48.9,14.95,41.14,0.006356060000000001,-0.11427929999999999,43.2,1.6847133673628805,15.993867689825063,3.850783713196872e-12,0.15856452071296964,106.09637601205553,3.6047150728554196,-0.2879,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-620,WAAREE ENERGIES LIMITED,Mono-c-Si,1,620.0,576.9,3.0,,,66.0,17.46,45.13,16.52,37.55,0.0029856600000000002,-0.15479590000000001,46.58,1.6077334024458574,17.4736028371115,1.1111350933225388e-11,0.15378330067022725,197.38944290473628,-23.451154408927657,-0.3373,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-02-620,WAAREE ENERGIES LIMITED,Mono-c-Si,1,620.0,588.0,2.8,,,60.0,18.17,43.26,17.15,36.15,0.0066683900000000015,-0.10347792,43.9,1.4889939231816358,18.189266327098796,4.307395617807231e-12,0.13873156977266582,130.83721045394427,1.0703541088470285,-0.2948,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-17-620,WAAREE ENERGIES LIMITED,Mono-c-Si,1,620.0,586.8,2.77,,,78.0,13.83,56.71,13.07,47.44,0.004605390000000001,-0.13899621,43.8,1.979044394162982,13.84248767768759,4.8905037541557024e-12,0.22985428869109167,254.56171985648774,1.9678702894796418,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-620,WAAREE ENERGIES LIMITED,Mono-c-Si,1,620.0,590.4,2.7,,,44.0,16.02,49.1,15.0,41.33,0.006375960000000001,-0.11474670000000001,43.2,1.6918585195099827,16.04351211000186,3.880543946693926e-12,0.15708378901549247,107.02919902423524,3.6430962988601614,-0.2879,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-625,WAAREE ENERGIES LIMITED,Mono-c-Si,1,625.0,581.7,3.0,,,66.0,17.52,45.29,16.62,37.61,0.00299592,-0.15534470000000003,46.58,1.6098935924740123,17.530471042793668,1.0516069525922875e-11,0.15892647092992399,265.9135136523834,-23.823921761333597,-0.3373,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-02-625,WAAREE ENERGIES LIMITED,Mono-c-Si,1,625.0,592.8,2.8,,,60.0,18.21,43.44,17.19,36.36,0.006683070000000001,-0.10390848,43.9,1.496255580805175,18.228724074016768,4.4071949584341334e-12,0.13506712159168696,131.35882097021536,1.243371508986139,-0.2948,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-17-625,WAAREE ENERGIES LIMITED,Mono-c-Si,1,625.0,591.7,2.77,,,78.0,13.88,56.88,13.13,47.6,0.004622040000000001,-0.13941288000000002,43.8,1.9844490518650437,13.891559973188626,4.876271287066675e-12,0.22823330083649956,274.0385439741015,1.9089163114107548,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-625,WAAREE ENERGIES LIMITED,Mono-c-Si,1,625.0,595.2,2.7,,,44.0,16.07,49.3,15.05,41.53,0.006395860000000001,-0.1152141,43.2,1.6991957661763846,16.09305984757697,3.9231155775589105e-12,0.15485846511428641,107.91812607692003,3.7091946340719173,-0.2879,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-630,WAAREE ENERGIES LIMITED,Mono-c-Si,1,630.0,586.5,3.0,,,66.0,17.58,45.45,16.73,37.67,0.00300618,-0.15589350000000002,46.58,1.6116431890126506,17.586261636078046,9.889559085603217e-12,0.164012060524059,460.47582617822576,-24.236291979026067,-0.3373,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-02-630,WAAREE ENERGIES LIMITED,Mono-c-Si,1,630.0,597.7,2.8,,,60.0,18.26,43.56,17.23,36.56,0.006701420000000001,-0.10419552000000001,43.9,1.5026009388556452,18.27855527846092,4.608901821775777e-12,0.1284891271964634,126.44442225664059,1.598074155755113,-0.2948,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-17-630,WAAREE ENERGIES LIMITED,Mono-c-Si,1,630.0,596.5,2.77,,,78.0,13.94,57.02,13.2,47.73,0.00464202,-0.13975602,43.8,1.9886771277193842,13.950627979228358,4.856811504875303e-12,0.22676837882701414,297.4367104066409,1.8348310034562374,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED BiN-21-630,WAAREE ENERGIES LIMITED,Mono-c-Si,1,630.0,600.1,2.7,,,44.0,16.12,49.5,15.1,41.72,0.00641576,-0.11568149999999999,43.2,1.7063394992479757,16.142714041240563,3.952909463096069e-12,0.15340045126084348,108.86725305895725,3.746641435334615,-0.2879,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-635,WAAREE ENERGIES LIMITED,Mono-c-Si,1,635.0,591.3,3.0,,,66.0,17.65,45.61,16.83,37.73,0.00301815,-0.1564423,46.58,1.6143063117275767,17.653417422674497,9.443839772165822e-12,0.16890818340580593,872.3619432271116,-24.552023369386557,-0.3373,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-02-635,WAAREE ENERGIES LIMITED,Mono-c-Si,1,635.0,602.5,2.8,,,60.0,18.3,43.74,17.27,36.77,0.006716100000000002,-0.10462608,43.9,1.5098608389534576,18.31799579164847,4.713180760742378e-12,0.12486774321662235,126.97855963492427,1.7671878845894011,-0.2948,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-17-635,WAAREE ENERGIES LIMITED,Mono-c-Si,1,635.0,601.4,2.77,,,78.0,13.99,57.18,13.26,47.89,0.00465867,-0.14014818,43.8,1.9939058398904026,13.99970326415715,4.85481707612506e-12,0.22441718217318576,323.56084555699516,1.7972349428431482,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-640,WAAREE ENERGIES LIMITED,Mono-c-Si,1,640.0,596.1,3.0,,,66.0,17.71,45.77,16.94,37.79,0.00302841,-0.15699110000000002,46.58,1.6174150252126178,17.7100030407871,9.087567463461147e-12,0.17169594705204816,999999.5712796414,-24.8169861820242,-0.3373,N,2025.7.3,6/23/2025,2.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-02-640,WAAREE ENERGIES LIMITED,Mono-c-Si,1,640.0,607.4,2.8,,,60.0,18.34,43.86,17.31,36.97,0.006730780000000001,-0.10491312,43.9,1.515829416017975,18.357127603591184,4.890844433158512e-12,0.11844034102383436,126.82427199012461,2.0602978112640615,-0.2948,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-17-640,WAAREE ENERGIES LIMITED,Mono-c-Si,1,640.0,606.2,2.77,,,78.0,14.05,57.33,13.33,48.01,0.004678650000000001,-0.14051583,43.8,1.998130173743596,14.058831417634995,4.811308217804192e-12,0.22459080359288802,357.3039880542802,1.6816195625352717,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-645,WAAREE ENERGIES LIMITED,Mono-c-Si,1,645.0,600.9,3.0,,,66.0,17.78,45.94,17.04,37.87,0.0030403800000000005,-0.1575742,46.58,1.6236541766840997,17.780003034378858,9.160405744435416e-12,0.17065923222864562,999997.5344922828,-24.79225425137478,-0.3373,N,2025.7.3,6/23/2025,2.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-02-645,WAAREE ENERGIES LIMITED,Mono-c-Si,1,645.0,612.2,2.8,,,60.0,18.39,43.98,17.35,37.18,0.006749130000000001,-0.10520015999999999,43.9,1.5223682377997376,18.40673875130762,5.128448189071167e-12,0.11129627340882958,122.27545724185087,2.4402819868177286,-0.2948,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-17-645,WAAREE ENERGIES LIMITED,Mono-c-Si,1,645.0,611.1,2.77,,,78.0,14.11,57.49,13.39,48.17,0.0046986300000000005,-0.14090799000000004,43.8,2.004010455673701,14.118601189067618,4.85397801873617e-12,0.22206513331531702,364.2913811389951,1.718918242753438,-0.3084,N,2025.7.3,6/23/2025,4.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-650,WAAREE ENERGIES LIMITED,Mono-c-Si,1,650.0,605.7,3.0,,,66.0,17.84,46.09,17.16,37.91,0.0030506400000000003,-0.15808870000000003,46.58,1.6301690800693416,17.840255332288635,9.385019850741726e-12,0.16588396535827382,11590.270797096398,-24.663798800176735,-0.3373,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-655,WAAREE ENERGIES LIMITED,Mono-c-Si,1,655.0,610.4,3.0,,,66.0,17.9,46.26,17.29,37.94,0.0030609,-0.15867180000000003,46.58,1.6374512101024317,17.90013422939165,9.626341426076288e-12,0.1887957196907326,25176.639840152548,-24.52889833406065,-0.3373,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED Bi-68-660,WAAREE ENERGIES LIMITED,Mono-c-Si,1,660.0,615.2,3.0,,,66.0,17.98,46.4,17.35,38.06,0.0030745800000000004,-0.159152,46.58,1.641772761153582,17.9801325712944,9.564464143786528e-12,0.18836531919884988,25547.08493654735,-24.59589196775948,-0.3373,N,2025.7.3,6/23/2025,2.0,first_pass +WAAREE ENERGIES LIMITED BiN-03-680,WAAREE ENERGIES LIMITED,Mono-c-Si,1,680.0,644.6,3.08,,,66.0,18.16,47.55,17.14,39.67,0.0053572,-0.1144053,43.6,1.636033864186911,18.179679451912286,4.258395377601544e-12,0.15679624003491305,144.68999112863332,0.4943347351373433,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-03-685,WAAREE ENERGIES LIMITED,Mono-c-Si,1,685.0,649.4,3.08,,,66.0,18.2,47.7,17.18,39.87,0.005369,-0.11476620000000001,43.6,1.6425470247863276,18.219081910770274,4.3710416621220795e-12,0.15199558991739684,144.97079314839814,0.6928485127535596,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-03-690,WAAREE ENERGIES LIMITED,Mono-c-Si,1,690.0,654.3,3.08,,,66.0,18.24,47.8,17.21,40.09,0.005380799999999999,-0.11500679999999999,43.6,1.648966540171736,18.25878292621292,4.6125279796891096e-12,0.14295683572066262,138.824624893991,1.1251934968380244,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-03-695,WAAREE ENERGIES LIMITED,Mono-c-Si,1,695.0,659.1,3.08,,,66.0,18.28,48.0,17.25,40.29,0.0053926,-0.115488,43.6,1.6563913309340015,18.29844675156148,4.665720121927831e-12,0.1411219730873028,139.84628469137948,1.2022290090294434,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-03-700,WAAREE ENERGIES LIMITED,Mono-c-Si,1,700.0,664.0,3.08,,,66.0,18.32,48.15,17.29,40.49,0.0054044,-0.1158489,43.6,1.6629011477549258,18.33782605041353,4.785821668409612e-12,0.13639218457127472,140.17153354297972,1.3961455051924572,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-03-705,WAAREE ENERGIES LIMITED,Mono-c-Si,1,705.0,668.8,3.08,,,66.0,18.36,48.3,17.33,40.68,0.0054161999999999995,-0.1162098,43.6,1.6692162399037813,18.377276809351386,4.89167777566257e-12,0.13234082996947802,140.63809994200773,1.5607267335740322,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +WAAREE ENERGIES LIMITED BiN-03-710,WAAREE ENERGIES LIMITED,Mono-c-Si,1,710.0,673.7,3.08,,,66.0,18.4,48.45,17.36,40.9,0.005428,-0.11657070000000001,43.6,1.6765520158982579,18.417126799841956,5.084157143875728e-12,0.12631115752386077,135.7010837958378,1.8686466441694547,-0.3018,N,2025.7.3,6/23/2025,4.0,bootstrapping +Walters & Wolf Glass Co VL-A200-1-0804-160W-M,Walters & Wolf Glass Co,Mono-c-Si,0,160.0,148.6,1.03,,,32.0,8.88,22.13,8.31,19.09,0.0029304,-0.0586445,43.8,0.8430687630648966,8.884272019328805,3.442708496646604e-11,0.044791075724170334,93.10462424084287,14.554360671469246,-0.362,Y,2025.7.3,6/23/2025,4.0,first_pass +Walters & Wolf Glass Co VL-C300-1-0904-175W-M,Walters & Wolf Glass Co,Mono-c-Si,0,175.0,162.6,1.13,,,36.0,9.06,25.03,8.31,21.6,0.0029898000000000004,-0.06632950000000001,43.8,0.9640650861472588,9.067271538878504,4.567238679990816e-11,0.04437180547560924,55.285210685378914,17.099155835969416,-0.362,Y,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-385MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,385.0,358.9,1.93,,,54.0,13.52,36.72,12.65,30.44,0.0048671999999999995,-0.0910656,46.9,1.3046643728029956,13.543034045151662,7.882275908635481e-12,0.17273037682848377,101.38534865863383,4.980100259874282,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-390MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,390.0,358.8,1.93,,,54.0,13.5,36.54,12.82,30.42,0.00621,-0.1008504,47.5,1.3879834934395288,13.503850787126767,4.953478965315518e-11,0.1444058550062292,506.2547100992174,9.227222506518219,-0.369,N,2025.7.3,6/23/2025,4.0,bootstrapping +Win Win Precision Technology Co Ltd WST-390MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,390.0,363.7,1.93,,,54.0,13.61,36.85,12.73,30.64,0.0048996,-0.091388,46.9,1.311426343140762,13.632572319246549,8.302626644257923e-12,0.16389302103813574,98.81944325851849,5.372223857361385,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-390MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,390.0,360.9,1.93,,,54.0,13.6,36.81,12.83,30.4,0.005168,-0.09762012,46.7,1.3650703967035729,13.612014426481453,2.6109433481441903e-11,0.17141156934307517,194.03317501761623,8.037213270621239,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-395MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,395.0,363.6,1.93,,,54.0,13.55,36.74,12.88,30.63,0.006233000000000001,-0.1014024,47.5,1.3959391909035854,13.553015907381301,5.0105897232740357e-11,0.14083311029782378,632.7411607718363,9.292025859211904,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-395MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,395.0,371.0,1.9,,,54.0,13.59,37.0,12.75,31.0,0.005436,-0.09028,45.0,1.3229359961832887,13.607247430661891,9.479645067248302e-12,0.14327140615106065,112.889766098303,8.219486049840956,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-395MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,395.0,368.5,1.93,,,54.0,13.7,36.98,12.81,30.84,0.004931999999999999,-0.09171039999999998,46.9,1.318187700051062,13.722047168350398,8.740866780156953e-12,0.15516873164520875,96.42107294273839,5.76150153249017,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-395MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,395.0,365.7,1.93,,,54.0,13.71,36.94,12.92,30.57,0.0052098,-0.09796488,46.7,1.3720222073205768,13.722971297602829,2.740637545253245e-11,0.1650143476210528,174.41175088341876,8.39673383080809,-0.3571,N,2025.7.3,6/23/2025,4.0,bootstrapping +Win Win Precision Technology Co Ltd WST-400MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,400.0,368.3,1.93,,,54.0,13.6,36.94,12.96,30.84,0.006256,-0.10195440000000001,47.5,1.3995870978914378,13.601000378550427,4.6815614649354476e-11,0.1379602576522344,1875.5497542232642,8.651741773774383,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-400MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,400.0,375.8,1.9,,,54.0,13.68,37.2,12.84,31.2,0.005472,-0.09076800000000002,45.0,1.3036025814107426,13.697952198629057,5.4036653197300564e-12,0.14499823039336981,110.49208149400556,3.300386391731143,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-400MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,400.0,373.3,1.93,,,54.0,13.79,37.07,12.9,31.01,0.004964399999999999,-0.0919336,46.9,1.32310359805635,13.810725153489155,9.124979451931758e-12,0.14613739467925005,97.23617617213263,6.075872618523956,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-400MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,400.0,370.4,1.93,,,54.0,13.79,37.03,13.03,30.71,0.0052401999999999995,-0.09820356,46.7,1.3750949874877019,13.800074199055606,2.7501035481798503e-11,0.15878127862195013,217.34670915385206,8.364904316448886,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-405MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,405.0,373.1,1.93,,,54.0,13.65,37.14,13.05,31.03,0.006279000000000001,-0.10250640000000001,47.5,1.4115491943865222,13.65006985941657,5.106740190828128e-11,0.13542353117133768,26460.78290974756,9.379997051812856,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-405MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,405.0,380.6,1.9,,,54.0,13.78,37.4,12.92,31.4,0.005512,-0.091256,45.0,1.3389953290016152,13.797415069520012,9.962205203327317e-12,0.13704597098051136,108.44019211888302,8.539713740503814,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-405MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,405.0,378.1,1.93,,,54.0,13.87,37.23,12.98,31.21,0.004993199999999999,-0.09233039999999999,46.9,1.3299481783943552,13.889767922533183,9.40234718455068e-12,0.14011929435292797,98.31354875474833,6.284214365032544,-0.32,N,2025.7.3,6/23/2025,4.0,bootstrapping +Win Win Precision Technology Co Ltd WST-405MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,405.0,375.2,1.93,,,54.0,13.86,37.15,13.13,30.86,0.0052668,-0.09852179999999999,46.7,1.3789845927791873,13.867428896432132,2.7415137575428388e-11,0.15418972274561438,287.6698586381442,8.282130965200185,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-410MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,410.0,377.8,1.93,,,54.0,13.7,37.34,13.12,31.23,0.0063019999999999994,-0.10305840000000002,47.5,1.3982157695455526,13.700003451664731,3.4568705471148556e-11,0.13634757662400557,541192.2641287751,5.952588816389665,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-410MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,410.0,385.5,1.9,,,54.0,13.86,37.5,13.0,31.6,0.005544,-0.0915,45.0,1.3447468091968335,13.876070356177303,1.0483516743697102e-11,0.12645119800456525,109.05881645491915,8.940599252418519,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-410MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,410.0,382.9,1.93,,,54.0,13.95,37.32,13.04,31.45,0.005021999999999999,-0.09255360000000001,46.9,1.3373388267929238,13.968923971639358,1.0301653401089682e-11,0.12515594993823734,92.25999372190951,7.036127729470942,-0.32,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-410MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,410.0,380.0,1.93,,,54.0,13.94,37.23,13.22,31.03,0.005297199999999999,-0.09873395999999998,46.7,1.3835731033149834,13.946268868831952,2.8483137380487656e-11,0.1446860603969464,321.7364673293911,8.563276882364033,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-415MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,415.0,382.6,1.93,,,54.0,14.02,37.38,13.31,31.19,0.0064491999999999996,-0.10316880000000002,47.5,1.4217504163301242,14.024236196716902,5.3214925413634634e-11,0.13610419960667255,450.4467271740629,9.528487688646,-0.369,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-415MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,415.0,384.8,1.93,,,54.0,14.02,37.38,13.31,31.19,0.005327599999999999,-0.09913176,46.7,1.3892249023638876,14.025280845986826,2.8722234554478926e-11,0.14148410270952197,375.6229891721826,8.582029243737379,-0.3571,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-435MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,435.0,402.6,2.14,,,60.0,13.66,41.02,12.91,33.76,0.006147,-0.11239480000000003,46.8,1.5283404165742465,13.669942710338047,2.983261319833821e-11,0.19878882612707044,273.1101794805922,5.5411048153583184,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-440MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,440.0,407.4,2.14,,,120.0,13.7,40.97,12.96,33.95,0.008219999999999998,-0.10570260000000001,47.3,1.5322804338021832,13.708470119890237,3.313631383741183e-11,0.17724209842336486,286.680332390674,12.863874593362834,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-440MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,440.0,407.3,2.14,,,60.0,13.71,41.11,13.01,33.89,0.0061695,-0.11264140000000002,46.8,1.5300135304123117,13.715394382446126,2.920640691168666e-11,0.193658781660064,492.19016105360186,5.31226097721679,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-440MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,440.0,408.4,2.14,,,60.0,13.7,40.97,12.96,33.95,0.006849999999999999,-0.1061123,46.9,1.5118963772014344,13.709203033394173,2.3092288113427274e-11,0.18070328156519694,269.0020645518531,9.308893736681682,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-445MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,445.0,412.2,2.14,,,120.0,13.77,41.08,13.05,34.1,0.008261999999999999,-0.10598640000000001,47.3,1.4860935466933407,13.77833862278268,1.347865868534081e-11,0.18023909429518678,297.63816045266213,4.848578299678628,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-445MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,445.0,412.1,2.14,,,60.0,13.79,41.18,13.11,34.0,0.006205499999999999,-0.11283320000000001,46.8,1.5324788774598959,13.79343904524755,2.936363172084547e-11,0.18832624065788045,755.1569618256545,5.301171523721311,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-445MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,445.0,413.2,2.14,,,60.0,13.77,41.08,13.05,34.1,0.006885,-0.1063972,46.9,1.5159600794287686,13.777294533777594,2.3257923954571334e-11,0.17516688371325256,330.66513815448906,9.319705645535993,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-450MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,450.0,417.0,2.14,,,120.0,13.83,41.15,13.15,34.22,0.008298,-0.106167,47.3,1.5347655644451361,13.830005209598177,3.131664408041235e-11,0.16672373029164003,442613.3302150908,10.793816138401363,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-450MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,450.0,416.9,2.14,,,60.0,13.86,41.3,13.2,34.15,0.0062369999999999995,-0.113162,46.8,1.536811485983431,13.86161403491935,2.9501151362860935e-11,0.1835422650884398,1576.109637183045,5.290779039798459,-0.356,N,2025.7.3,6/23/2025,4.0,bootstrapping +Win Win Precision Technology Co Ltd WST-450MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,450.0,417.9,2.14,,,60.0,13.83,41.15,13.15,34.22,0.006915000000000001,-0.10657849999999999,46.9,1.5175642990472562,13.834042702245606,2.303902458258138e-11,0.16945812171628474,579.7127100575963,9.183326201756854,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-455MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,455.0,421.7,2.14,,,120.0,13.9,41.28,13.27,34.29,0.00834,-0.1065024,47.3,1.5399271139486277,13.900081225056011,3.17010456184387e-11,0.1691223916055412,28941.8640279377,12.28993926592379,-0.347,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-455MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,455.0,421.7,2.14,,,60.0,13.92,41.51,13.27,34.34,0.006264,-0.1137374,46.8,1.544288978448613,13.920622455963974,2.948779994613895e-11,0.1822997100761118,4076.7763278042207,5.246111501609402,-0.356,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-455MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,455.0,422.7,2.14,,,60.0,13.9,41.28,13.27,34.29,0.006950000000000001,-0.1069152,46.9,1.518649517126476,13.90001597598656,2.1776818086681652e-11,0.17263699936333962,150204.3290956027,8.621868049642641,-0.343,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-460MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,460.0,427.5,2.14,,,60.0,13.99,41.45,13.37,34.41,0.006995,-0.1073555,46.9,1.5251670672797593,13.990002393097425,2.2021309221892868e-11,0.17104875744556203,999989.3854066548,8.663380290070284,-0.343,N,2025.7.3,6/23/2025,2.0,first_pass +Win Win Precision Technology Co Ltd WST-525MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,525.0,489.5,2.56,,,77.0,13.65,49.16,12.81,40.97,0.008736,-0.1312572,46.3,1.8327328394170705,13.665697176308665,2.999843411379682e-11,0.195083684949204,169.6414860657994,8.165511212314417,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-530MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,530.0,494.9,2.56,,,77.0,13.71,49.25,12.91,41.06,0.0087744,-0.1265725,47.1,1.7628083941835586,13.724950836261932,9.901249745458868e-12,0.20575375608162041,188.6773391030004,2.647934635972616,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-530MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,530.0,498.0,2.51,,,72.0,13.71,49.4,12.82,41.4,0.005484,-0.12053599999999999,45.0,1.7693072437876858,13.73016686442373,9.990003707222204e-12,0.18836163125118355,128.05351968283628,8.621218957239984,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-530MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,530.0,494.3,2.56,,,77.0,13.71,49.28,12.89,41.12,0.0087744,-0.13157760000000002,46.3,1.8366995994648063,13.723857155043303,2.996939906693406e-11,0.1904069178217229,188.38490671659784,8.111403506822997,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-530MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,530.0,497.3,2.56,,,72.0,13.71,49.25,12.91,41.06,0.0074034,-0.12952750000000002,46.5,1.7508972447819102,13.725359330146004,8.184966323515934e-12,0.20783045840336448,185.51301155170887,-1.1263577505090172,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-530MGX-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,530.0,498.0,2.51,,,72.0,13.71,49.4,12.82,41.4,0.005484,-0.12053599999999999,45.0,1.7693072437876858,13.73016686442373,9.990003707222204e-12,0.18836163125118355,128.05351968283628,8.621218957239984,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-535MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,535.0,499.7,2.56,,,77.0,13.79,49.38,12.99,41.18,0.0088256,-0.1269066,47.1,1.7976076547116466,13.80363518465705,1.592938466439993e-11,0.19888902783131834,201.14723589180315,6.6654162036726206,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-535MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,535.0,502.8,2.51,,,72.0,13.78,49.5,12.9,41.5,0.005512,-0.12078,45.0,1.772275904121125,13.799170802645637,9.957344947832093e-12,0.18644913799006124,134.01990382563108,8.542009457042687,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-535MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,535.0,499.0,2.56,,,77.0,13.79,49.41,12.97,41.25,0.0088256,-0.1319247,46.3,1.8417047827213253,13.803504628676357,3.022623228137383e-11,0.18792679007491161,191.89794258086494,8.133957543826854,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-535MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,535.0,502.1,2.56,,,72.0,13.79,49.38,12.99,41.18,0.007446599999999999,-0.12986940000000002,46.5,1.7554668321160212,13.805043172251834,8.229108593360962e-12,0.20616892969444298,188.9940166054077,-1.1312650566248679,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-535MGX-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,535.0,502.8,2.51,,,72.0,13.78,49.5,12.9,41.5,0.005512,-0.12078,45.0,1.772275904121125,13.799170802645637,9.957344947832093e-12,0.18644913799006124,134.01990382563108,8.542009457042687,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-540MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,540.0,504.5,2.56,,,77.0,13.85,49.51,13.07,41.32,0.008864,-0.1272407,47.1,1.8014905305878048,13.861891452733417,1.5824983031368813e-11,0.19590983128079692,228.17659334148857,6.563171310303353,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-540MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,540.0,507.6,2.51,,,72.0,13.85,49.7,12.97,41.7,0.005540000000000001,-0.12126800000000001,45.0,1.7798208013774126,13.868718199199433,1.0071807811702748e-11,0.1834388382189799,135.73035988115188,8.597104429714843,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-540MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,540.0,506.9,2.56,,,72.0,13.85,49.51,13.07,41.32,0.007479,-0.1302113,46.5,1.759262875719759,13.863233176623975,8.17314997914019e-12,0.20316114339487637,212.63086884894824,-1.2287043247862404,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-540MGX-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,540.0,507.6,2.51,,,72.0,13.85,49.7,12.97,41.7,0.005540000000000001,-0.12126800000000001,45.0,1.7798208013774126,13.868718199199433,1.0071807811702748e-11,0.1834388382189799,135.73035988115188,8.597104429714843,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-545MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,545.0,509.3,2.56,,,77.0,13.93,49.64,13.15,41.46,0.0089152,-0.12757480000000002,47.1,1.806611881914949,13.941525024402127,1.6016663193726067e-11,0.19257622145231656,232.7619180388031,6.616705907490754,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-545MGXB-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,545.0,512.5,2.51,,,72.0,13.92,49.8,13.04,41.8,0.005568,-0.121512,45.0,1.7834488363278773,13.938398341520973,1.0133850727767049e-11,0.18150439092867762,137.32439541826813,8.605423130025976,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-545MGXC-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,1,545.0,508.6,2.56,,,77.0,13.93,49.68,13.12,41.55,0.0089152,-0.1326456,46.3,1.8522056027530325,13.94207334117342,3.077221138060784e-11,0.1806485521625022,208.4289933915517,8.19748948819619,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-545MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,545.0,511.7,2.56,,,72.0,13.93,49.64,13.15,41.46,0.007522200000000001,-0.1305532,46.5,1.764262155084406,13.942851004491345,8.27306551518013e-12,0.199807673220431,216.5839173675848,-1.1780430067237841,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-545MGX-E5,Win Win Precision Technology Co Ltd,Mono-c-Si,0,545.0,512.5,2.51,,,72.0,13.92,49.8,13.04,41.8,0.005568,-0.121512,45.0,1.7834488363278773,13.938398341520973,1.0133850727767049e-11,0.18150439092867762,137.32439541826813,8.605423130025976,-0.319,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-550MGXB-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,550.0,514.1,2.56,,,77.0,14.0,49.77,13.23,41.59,0.008960000000000001,-0.12790890000000002,47.1,1.8109049318376145,14.010543714117881,1.600945100597173e-11,0.19034112003735468,252.73595765617506,6.564945328339631,-0.314,N,2025.7.3,6/23/2025,4.0,first_pass +Win Win Precision Technology Co Ltd WST-550MGX-E2,Win Win Precision Technology Co Ltd,Mono-c-Si,0,550.0,516.5,2.56,,,72.0,14.0,49.77,13.23,41.59,0.007560000000000001,-0.13089510000000001,46.5,1.768456724020351,14.011832635713256,8.26828690437143e-12,0.1975465253100821,233.73079641114836,-1.2274094564056945,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-230P6,WINAICO,Multi-c-Si,0,230.0,206.5,1.642087,1.657,0.991,60.0,8.3,38.86,7.72,29.81,0.00498,-0.143782,44.9,1.638509344786595,8.313958305181622,4.1097682448152576e-10,0.5759765908089716,342.4920220831284,0.15859346158806412,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-235P6,WINAICO,Multi-c-Si,0,235.0,211.1,1.642087,1.657,0.991,60.0,8.35,36.92,7.84,29.95,0.00501,-0.136604,44.9,1.6019334614905547,8.354851534934502,8.10746940091194e-10,0.29444875521103026,506.7774697231069,5.76477175982409,-0.48,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-260M6,WINAICO,Mono-c-Si,0,260.0,234.9,1.663335,1.665,0.999,60.0,9.05,37.67,8.56,30.41,0.005701500000000001,-0.12167410000000002,46.2,1.5493640340319113,9.051123609637479,2.494036557748451e-10,0.3161432577089398,2546.346720906535,9.474171335122163,-0.437,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-265M6,WINAICO,Mono-c-Si,0,265.0,239.6,1.663335,1.665,0.999,60.0,9.14,37.86,8.69,30.5,0.005758200000000001,-0.1222878,46.2,1.5575031902164647,9.14000280955275,2.5354498450125213e-10,0.30724936660582686,999999.6090264441,9.527622271569385,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WSP-265P6,WINAICO,Multi-c-Si,0,265.0,239.0,1.663335,1.665,0.999,60.0,9.21,38.1,8.49,31.26,0.00605097,-0.1382649,45.2,1.669326356730411,9.2268132472425,1.0919883361240983e-09,0.22680242503327155,124.23838434416153,9.61778383622672,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WST-265P6,WINAICO,Multi-c-Si,0,265.0,239.0,1.663335,1.665,0.999,60.0,9.21,38.1,8.49,31.26,0.00605097,-0.1382649,45.2,1.669326356730411,9.2268132472425,1.0919883361240983e-09,0.22680242503327155,124.23838434416153,9.61778383622672,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-270M6,WINAICO,Mono-c-Si,0,270.0,244.2,1.663335,1.665,0.999,60.0,9.24,38.06,8.83,30.59,0.0058212,-0.12293380000000002,46.2,1.5678472197810778,9.2400385873516,2.648553749560767e-10,0.29267934722478073,70086.22483058684,9.818099976458111,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WSP-270P6,WINAICO,Multi-c-Si,0,270.0,243.7,1.663335,1.665,0.999,60.0,9.31,38.32,8.65,31.27,0.006116669999999999,-0.13906327999999998,45.2,1.6659305636679573,9.323060477302937,9.326846341768724e-10,0.2505142539028517,178.5760319925518,8.098110455698489,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WST-270P6,WINAICO,Multi-c-Si,0,270.0,243.7,1.663335,1.665,0.999,60.0,9.31,38.32,8.65,31.27,0.006116669999999999,-0.13906327999999998,45.2,1.6659305636679573,9.323060477302937,9.326846341768724e-10,0.2505142539028517,178.5760319925518,8.098110455698489,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-275M6,WINAICO,Mono-c-Si,0,275.0,248.9,1.663335,1.665,0.999,60.0,9.34,38.25,8.88,30.98,0.0058842,-0.1235475,46.2,1.5774751711941863,9.3400026521483,2.7525977582782563e-10,0.28382688053100263,999999.9678180289,10.06462014613439,-0.437,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WSP-275P6,WINAICO,Multi-c-Si,0,275.0,248.3,1.663335,1.665,0.999,60.0,9.41,38.52,8.81,31.28,0.0061823699999999995,-0.13978908,45.2,1.6626269929542727,9.41805139030041,8.063270695374626e-10,0.27084672446541574,316.5501238142922,6.70776719975944,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WST-275P6,WINAICO,Multi-c-Si,0,275.0,248.3,1.663335,1.665,0.999,60.0,9.41,38.52,8.81,31.28,0.0061823699999999995,-0.13978908,45.2,1.6626269929542727,9.41805139030041,8.063270695374626e-10,0.27084672446541574,316.5501238142922,6.70776719975944,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-280M6,WINAICO,Mono-c-Si,0,280.0,253.5,1.663335,1.665,0.999,60.0,9.44,38.45,8.93,31.37,0.0059472,-0.12419350000000003,46.2,1.5907888734035782,9.44169963851958,2.9976468372495686e-10,0.2658819392623844,1476.7407818834477,10.738723662213918,-0.437,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-280P6,WINAICO,Multi-c-Si,0,280.0,253.0,1.663335,1.665,0.999,60.0,9.52,38.71,8.97,31.29,0.006254639999999999,-0.14047859,45.2,1.6604910671676658,9.522893611936208,7.119809211769403e-10,0.288759049634349,950.019920065061,5.513427718093222,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WST-280P6,WINAICO,Multi-c-Si,0,280.0,253.0,1.663335,1.665,0.999,60.0,9.52,38.71,8.97,31.29,0.006254639999999999,-0.14047859,45.2,1.6604910671676658,9.522893611936208,7.119809211769403e-10,0.288759049634349,950.019920065061,5.513427718093222,-0.4683,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-285M6,WINAICO,Mono-c-Si,0,285.0,259.9,1.663335,1.665,0.999,60.0,9.54,38.64,8.98,31.76,0.005667714,-0.11251968000000001,45.1,1.584448021791875,9.546037940322352,2.4209570791721034e-10,0.23909833305136868,377.7775648551596,20.803457957343895,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-285P6,WINAICO,Multi-c-Si,0,285.0,257.6,1.663335,1.665,0.999,60.0,9.57,38.92,9.11,31.3,0.00628749,-0.14124068,45.2,1.668005922938851,9.570002689169032,7.037337276337601e-10,0.2807052810534376,999999.8548707531,5.357812059402813,-0.4683,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WST-285M6,WINAICO,Mono-c-Si,0,285.0,259.9,1.663335,1.665,0.999,60.0,9.54,38.64,8.98,31.76,0.005667714,-0.11251968000000001,45.1,1.584448021791875,9.546037940322352,2.4209570791721034e-10,0.23909833305136868,377.7775648551596,20.803457957343895,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WST-285P6,WINAICO,Multi-c-Si,0,285.0,257.6,1.663335,1.665,0.999,60.0,9.57,38.92,9.11,31.3,0.00628749,-0.14124068,45.2,1.668005922938851,9.570002689169032,7.037337276337601e-10,0.2807052810534376,999999.8548707531,5.357812059402813,-0.4683,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WSP-290M6,WINAICO,Mono-c-Si,0,290.0,264.6,1.663335,1.665,0.999,60.0,9.64,38.83,9.03,32.12,0.005727124000000001,-0.11307296,45.1,1.6018390043634765,9.648780283968527,2.8130073710047577e-10,0.21081157599942957,231.45307900092078,22.198183400737225,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WST-290M6,WINAICO,Mono-c-Si,0,290.0,264.6,1.663335,1.665,0.999,60.0,9.64,38.83,9.03,32.12,0.005727124000000001,-0.11307296,45.1,1.6018390043634765,9.648780283968527,2.8130073710047577e-10,0.21081157599942957,231.45307900092078,22.198183400737225,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-295M6,WINAICO,Mono-c-Si,0,295.0,269.3,1.663335,1.665,0.999,60.0,9.75,39.19,9.14,32.28,0.005792475,-0.11412127999999999,45.1,1.612273062699285,9.758885871705758,2.665944400272106e-10,0.22811959643383228,250.30365632258383,21.552518670195724,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-295MX,WINAICO,Mono-c-Si,0,295.0,271.9,1.75,,,60.0,10.54,35.96,10.07,29.29,0.00441626,-0.10280964000000001,45.1,1.3670860067730155,10.540002531079951,3.97286015747965e-11,0.2401199994657605,999999.2850045392,5.68478615575947,-0.3813,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WSP-300M6,WINAICO,Mono-c-Si,0,300.0,274.0,1.663335,1.665,0.999,60.0,9.86,39.8,9.31,32.3,0.005857825999999999,-0.11589759999999999,45.1,1.61819588130545,9.863843278069451,2.042159899139679e-10,0.2905937863493629,745.5238529456117,18.81931503702355,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-300MX,WINAICO,Mono-c-Si,0,300.0,276.7,1.75,,,60.0,10.2,37.95,9.19,32.68,0.0042737999999999995,-0.10849905000000001,45.1,1.5278488287518541,10.209376439461384,1.5514837807766007e-10,0.049787826982312655,54.160840103948274,18.5246057960602,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-305M6,WINAICO,Mono-c-Si,0,305.0,278.7,1.663335,1.665,0.999,60.0,9.96,40.1,9.36,32.6,0.005917236,-0.11677120000000002,45.1,1.6358328867747085,9.96812049207113,2.22567592584068e-10,0.28255115994427255,346.55657349225464,19.57105838828779,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-305MX,WINAICO,Mono-c-Si,0,305.0,281.4,1.75,,,60.0,10.28,38.27,9.34,32.7,0.00430732,-0.10941393,45.1,1.526586661424323,10.293766684069071,1.2555970865291017e-10,0.08443035681477143,63.04670528932422,16.40984292490844,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-310M6,WINAICO,Mono-c-Si,0,310.0,283.4,1.663335,1.665,0.999,60.0,10.06,40.25,9.42,32.91,0.005976646,-0.117208,45.1,1.6501577208814462,10.070827105585176,2.5269625634501313e-10,0.25716468567518325,238.94446643583564,20.723764172503962,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-310MX,WINAICO,Mono-c-Si,0,310.0,286.1,1.75,,,60.0,10.35,38.6,9.48,32.72,0.00433665,-0.1103574,45.1,1.5259987233447052,10.36631922943477,1.0190688424319116e-10,0.1189588457568494,75.44621319557305,14.369637068536466,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-315M6,WINAICO,Mono-c-Si,0,315.0,288.2,1.663335,1.665,0.999,60.0,10.16,40.4,9.48,33.24,0.006036056000000001,-0.1176448,45.1,1.6650913434825814,10.1727592959732,2.8883076270046935e-10,0.22961134273836323,182.83543503161613,21.95482968958389,-0.4309,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-315MX,WINAICO,Mono-c-Si,0,315.0,290.9,1.75,,,60.0,10.42,38.93,9.63,32.74,0.00436598,-0.11130086999999998,45.1,1.5249372289061303,10.436375843689417,8.212192482520462e-11,0.15252331122600468,97.05105567136798,12.296884826836317,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-320MX,WINAICO,Mono-c-Si,0,320.0,295.6,1.75,,,60.0,10.48,39.26,9.77,32.76,0.00439112,-0.11224434,45.1,1.5243643320571962,10.494267639533046,6.661589817821459e-11,0.18504926334794852,135.9241168306449,10.329279231353622,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-325MX,WINAICO,Mono-c-Si,0,325.0,300.3,1.75,,,60.0,10.56,39.59,9.93,32.78,0.0044246400000000005,-0.11318781,45.1,1.5240885398804624,10.569970800066782,5.439959434345944e-11,0.2161045182583174,228.8746881617226,8.437180753873058,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-330MX,WINAICO,Mono-c-Si,0,330.0,305.1,1.75,,,60.0,10.62,39.93,10.07,32.8,0.0044497799999999995,-0.11415987,45.1,1.5244700781642495,10.62367018435101,4.4528752983164985e-11,0.2474885562431836,716.1298622754401,6.614244085181702,-0.3813,N,2025.7.3,6/23/2025,4.0,first_pass +WINAICO WSP-335MX,WINAICO,Mono-c-Si,0,335.0,309.8,1.75,,,60.0,10.68,40.27,10.21,32.82,0.00447492,-0.11513193000000001,45.1,1.5317452558480091,10.680002788575464,4.081779161742855e-11,0.26108253658373004,999999.0257486226,5.8029459380760215,-0.3813,N,2025.7.3,6/23/2025,2.0,first_pass +WINAICO WSP-340MX,WINAICO,Mono-c-Si,0,340.0,314.6,1.75,,,60.0,10.74,40.61,10.35,32.85,0.00450006,-0.11610399,45.1,1.5450409846279876,10.740002737789208,4.130156026806114e-11,0.2547983640840076,999615.2394850717,5.855704274529252,-0.3813,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT405M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,405.0,380.7,1.95,,,54.0,13.83,37.54,13.09,30.94,0.0065001,-0.0961024,46.4,1.300632555675538,13.842718981521694,3.98627610588373e-12,0.19245051426512158,209.26130079749774,-4.232308173821319,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT410M10-108D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,410.0,385.4,1.95,,,54.0,13.93,38.2,12.98,31.6,0.0062685,-0.10161200000000002,46.2,1.3413105346798944,13.960039200119104,5.782646928215678e-12,0.1831494099497945,84.93139704677849,-4.953000102152026,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT410M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,410.0,385.5,1.95,,,54.0,13.91,37.73,13.17,31.13,0.0065377000000000005,-0.09658879999999999,46.4,1.307702185962371,13.92229957719565,4.053765687364471e-12,0.18941609371524296,214.21694641965158,-4.146105333414143,-0.294,N,2025.7.3,6/23/2025,4.0,bootstrapping +Wuxi Sunket New Energy Technology Co Ltd SKT415M10-108D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,415.0,390.3,1.95,,,54.0,14.01,38.33,13.06,31.79,0.0063045,-0.1019578,46.2,1.3473556656064054,14.038706519631797,6.002212227076267e-12,0.17550542712375095,85.65409769351037,-4.707108733026316,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT415M10-108S1,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,415.0,389.8,1.95,,,54.0,13.99,37.92,13.25,31.32,0.0064354,-0.10162560000000001,46.4,1.3526966545106023,13.990060360643385,9.359675517748442e-12,0.17986176114888983,41687.23217698952,-2.0275202293135766,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT415M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,415.0,390.4,1.95,,,54.0,13.99,37.92,13.25,31.32,0.0065753,-0.09707520000000001,46.4,1.3147711335772088,14.001889551906096,4.121712009757495e-12,0.18641887235449617,219.35225571841266,-4.060835806787135,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT420M10-108D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,420.0,395.1,1.95,,,54.0,14.09,38.46,13.14,31.97,0.0063405,-0.10230360000000001,46.2,1.353186239951398,14.117520646375409,6.200341570414865e-12,0.16882823167281844,86.43655219442869,-4.498098035857222,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT420M10-108S1,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,420.0,394.6,1.95,,,54.0,14.07,38.11,13.33,31.51,0.006472200000000001,-0.1021348,46.4,1.3513087714170213,14.080174989461018,7.865405822329004e-12,0.1785006138280424,246.83108092588407,-3.4211546763748926,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT420M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,420.0,395.2,1.95,,,54.0,14.07,38.11,13.33,31.51,0.0066129000000000005,-0.0975616,46.4,1.3218394646581997,14.081488730132218,4.19011537186175e-12,0.1834582018053867,224.67730345034678,-3.9765528330630913,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT425M10-108D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,425.0,399.9,1.95,,,54.0,14.17,38.59,13.22,32.16,0.006376499999999999,-0.10264940000000002,46.2,1.359225608951404,14.196230339261554,6.4311421097075e-12,0.16136910660265058,87.17387221771388,-4.256332824258573,-0.298,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT425M10-108S1,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,425.0,399.4,1.95,,,54.0,14.15,38.3,13.41,31.7,0.006509000000000001,-0.10264400000000001,46.4,1.3598648632251542,14.159744770374783,8.216802669963826e-12,0.17535382812253666,254.62443786625906,-3.1209804863785116,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT425M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,425.0,400.0,1.95,,,54.0,14.15,38.3,13.41,31.7,0.006650500000000001,-0.09804800000000001,46.4,1.3187771746424954,14.1500048951187,3.4510385950753534e-12,0.18207814645717207,526323.6556168093,-5.588153537835484,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT430M10-108D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,430.0,404.7,1.95,,,54.0,14.25,38.72,13.3,32.34,0.006412500000000001,-0.10299520000000001,46.2,1.3650512997072666,14.275085246178051,6.639151875482027e-12,0.15486211368891484,87.97143572582686,-4.051033767897369,-0.298,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT430M10-108S1,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,430.0,404.2,1.95,,,54.0,14.23,38.49,13.49,31.88,0.0065458,-0.10315320000000001,46.4,1.348429806412778,14.240187129717697,5.650514629059296e-12,0.17637762172939217,246.37493996090944,-6.093381901348122,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT430M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,430.0,404.8,1.95,,,54.0,14.23,38.49,13.49,31.88,0.006688100000000001,-0.09853440000000001,46.4,1.335772143181728,14.240739378277661,4.309575000795221e-12,0.17848912956884833,236.50347894547437,-3.8452630451170577,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT435M10-108S1,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,435.0,409.0,1.95,,,54.0,14.31,38.69,13.57,32.07,0.0065826,-0.1036892,46.4,1.355750032440916,14.319837933428037,5.721559034725306e-12,0.17425868847483497,253.47211972885847,-6.0411530553457915,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT435M10-108S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,435.0,409.6,1.95,,,54.0,14.31,38.69,13.57,32.07,0.0067257,-0.09904639999999999,46.4,1.343018586068133,14.32038442473765,4.363558503876886e-12,0.17637101814767403,243.04372551589327,-3.791963527444015,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT455M10-120D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,455.0,426.5,2.16,,,60.0,13.91,41.87,13.17,34.56,0.0066768,-0.1071872,46.29,1.4824558329435256,13.920974231672412,7.456050858557761e-12,0.2037006307387688,258.19354551498344,0.7621752270539465,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT460M10-120D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,460.0,431.3,2.16,,,60.0,13.99,42.05,13.25,34.73,0.0067152,-0.107648,46.29,1.477587943272704,13.990005504837498,6.11832746773825e-12,0.20326359468129107,516577.6803752686,-0.5273335495355543,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT465M10-120D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,465.0,436.1,2.16,,,60.0,14.07,42.22,13.33,34.9,0.006753600000000001,-0.1080832,46.29,1.495482308816247,14.080246279391037,7.637330793017052e-12,0.1986887688072835,272.8357174087338,0.8640281440847359,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT470M10-120D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,470.0,440.9,2.16,,,60.0,14.15,42.38,13.41,35.06,0.006792000000000001,-0.1084928,46.29,1.5015146912878798,14.15988804477424,7.735897153167847e-12,0.19595312573733903,280.4130445775233,0.9221514648504139,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT475M10-120D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,475.0,445.7,2.16,,,60.0,14.23,42.54,13.49,35.22,0.0068304,-0.1089024,46.29,1.507547243111685,14.239537011449787,7.835052680802028e-12,0.1932501109772366,288.3449501420729,0.97985624861494,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT480M10-120D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,480.0,450.5,2.16,,,60.0,14.31,42.71,13.57,35.39,0.0068688,-0.10933760000000001,46.29,1.5139702341634869,14.31919008883245,7.940054431460703e-12,0.19047935189521037,296.59773506098975,1.0426537339352706,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT545M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,545.0,512.1,2.58,,,72.0,13.9,50.04,13.19,41.33,0.006255,-0.12359879999999998,46.2,1.7407952515697107,13.909300497385997,4.518945355224704e-12,0.2463985502636563,368.2534080107173,0.28969503851843204,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT545M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,545.0,512.5,2.58,,,72.0,13.9,50.04,13.19,41.32,0.006533000000000001,-0.1281024,46.4,1.7332900055519898,13.909556598654333,3.989404540839595e-12,0.2485076571134896,361.45249664899484,-4.27588407528601,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT550M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,550.0,516.9,2.58,,,72.0,13.98,50.18,13.26,41.48,0.006291,-0.1239446,46.2,1.7467054291713695,13.989834961953736,4.62063044259822e-12,0.24271614810570555,345.0111740953058,0.4285177381973787,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT550M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,550.0,517.4,2.58,,,72.0,13.98,50.18,13.26,41.47,0.0065706,-0.1284608,46.4,1.739183153121446,13.990095026731531,4.080050622660734e-12,0.24481784245877178,339.033619911081,-4.1414505667692945,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT555M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,555.0,521.7,2.58,,,72.0,14.06,50.32,13.33,41.64,0.006327,-0.1242904,46.2,1.7528164433837559,14.070336166541658,4.739391901301556e-12,0.23821711665803266,324.0401221830386,0.5937353216742461,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT555M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,555.0,522.2,2.58,,,72.0,14.06,50.32,13.33,41.62,0.0066082,-0.1288192,46.4,1.745075772635013,14.070617303487172,4.172121426149704e-12,0.24116712905592935,319.3663859492298,-4.007826777299887,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT560M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,560.0,526.5,2.58,,,72.0,14.13,50.67,13.35,41.96,0.0063585000000000004,-0.1251549,46.2,1.7683843910716561,14.144312977702134,5.010664833798948e-12,0.23604443170221454,233.02683077886164,1.0299932529658058,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT560M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,560.0,527.0,2.58,,,72.0,14.13,50.67,13.35,41.95,0.0066411000000000005,-0.1297152,46.4,1.760801454675363,14.14461124221676,4.428270907053979e-12,0.23814504681143484,230.3013983728057,-3.5595932734821116,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT565M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,565.0,531.4,2.58,,,72.0,14.19,50.87,13.41,42.15,0.0063855,-0.12564889999999998,46.2,1.7756594119847284,14.204010348453336,5.057137059633636e-12,0.23390407282055486,236.90337303218845,1.070684850505705,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT565M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,565.0,531.8,2.58,,,72.0,14.19,50.87,13.41,42.14,0.0066692999999999995,-0.1302272,46.4,1.7680491467581774,14.204305784958308,4.469714543527324e-12,0.2360002652806125,234.0901790021433,-3.5200041343711512,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT570M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,570.0,536.2,2.58,,,72.0,14.25,51.07,13.48,42.3,0.006412500000000001,-0.1261429,46.2,1.7815265266421996,14.262983697285364,4.994278542087833e-12,0.23518419430242984,258.1217585868652,0.9271495269912764,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT570M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,570.0,536.6,2.58,,,72.0,14.25,51.07,13.48,42.29,0.0066975,-0.1307392,46.4,1.7738846485855104,14.263271028943109,4.4133499588836556e-12,0.23727413026508307,254.777258353379,-3.658680309432831,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT575M10-144D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,1,575.0,541.0,2.58,,,72.0,14.31,51.27,13.55,42.45,0.0064395,-0.1266369,46.2,1.787398171049552,14.321942686530788,4.93299642298049e-12,0.23644962043646578,283.31933518839827,0.7853078879322029,-0.301,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT575M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,575.0,541.5,2.58,,,72.0,14.31,51.27,13.55,42.44,0.0067257,-0.1312512,46.4,1.7797247012888988,14.322221980701885,4.358407498112046e-12,0.2385333618073468,279.2847164285786,-3.7957168044531553,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT580M10-144S2,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,580.0,546.3,2.58,,,72.0,14.37,51.47,13.62,42.59,0.0067539,-0.13176320000000002,46.4,1.7855692268853511,14.381158853824024,4.3048400029480035e-12,0.23977821260552193,308.77837370878717,-3.9311434521380457,-0.294,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT590M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,590.0,553.0,2.79,,,78.0,13.71,54.75,13.14,44.91,0.0065808,-0.14016,46.29,1.9276020719263756,13.710003870583424,6.334290080690609e-12,0.28231431533121853,999996.5629525327,-0.4980617712714382,-0.311,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT595M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,595.0,557.8,2.79,,,78.0,13.79,54.9,13.2,45.1,0.0066191999999999996,-0.140544,46.29,1.933055275066276,13.79000387345566,6.387383468977431e-12,0.2808854907172316,999999.0413049096,-0.4773983013440872,-0.311,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT600M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,600.0,562.7,2.79,,,78.0,13.87,55.04,13.26,45.26,0.0066576,-0.1409024,46.29,1.9377792389982347,13.870003897653001,6.405117988984504e-12,0.28101010417601785,999999.6723416719,-0.5020092836628706,-0.311,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT605M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,605.0,567.5,2.79,,,78.0,13.95,55.17,13.32,45.43,0.006696,-0.14123520000000003,46.29,1.9436575437673773,13.950869989268224,6.560339136938667e-12,0.27698259074775855,4441.327572121262,-0.35025628799200587,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT610M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,610.0,572.3,2.79,,,78.0,14.03,55.31,13.38,45.61,0.006734400000000001,-0.14159360000000001,46.29,1.9509988066251414,14.032471934906198,6.82262055463238e-12,0.27057963267434926,1535.733123373278,-0.07028235817114543,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT615M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,615.0,577.1,2.79,,,78.0,14.11,55.44,13.44,45.78,0.006772800000000001,-0.1419264,46.29,1.9579541227378299,14.1140017658592,7.090067550001007e-12,0.2643336885845332,932.0256395356017,0.2043990864437379,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT620M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,620.0,581.9,2.79,,,78.0,14.19,55.58,13.5,45.94,0.0068112,-0.1422848,46.29,1.9648861748730972,14.195460204098286,7.326516372632711e-12,0.25973591621193587,675.0027061341123,0.43328132515537887,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Sunket New Energy Technology Co Ltd SKT625M10-156D5,Wuxi Sunket New Energy Technology Co Ltd,Mono-c-Si,0,625.0,586.7,2.79,,,78.0,14.27,55.72,13.56,46.11,0.0068496,-0.1426432,46.29,1.9720282692397237,14.27686816786676,7.591852493467922e-12,0.25433536881720975,528.4328509585279,0.6857650205801732,-0.311,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP255-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,255.0,233.1,1.62,,,60.0,8.86,37.6,8.28,30.8,0.00470466,-0.1203576,44.0,1.5523062673780739,8.8704750830257,2.6307964650009096e-10,0.26260079742255066,222.11216026402008,11.312976297927314,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP260-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,260.0,237.8,1.62,,,60.0,8.98,37.7,8.42,30.9,0.00476838,-0.12067770000000001,44.0,1.5542110443184858,8.988280286030323,2.5856239283229876e-10,0.25763304468502846,279.40398391491783,11.024438255050978,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP265-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,265.0,242.5,1.62,,,60.0,9.08,37.8,8.55,31.0,0.00482148,-0.1209978,44.0,1.555357793738014,9.085400561646995,2.5083341493757714e-10,0.2534598294596323,426.14375400421034,10.637828819119203,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP270-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,270.0,247.2,1.62,,,60.0,9.21,37.9,8.69,31.1,0.004890510000000001,-0.1213179,44.0,1.5583240652902715,9.21405165494435,2.504945481426563e-10,0.24833094653997856,564.4924156441631,10.49129715235871,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP270S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,270.0,245.3,1.62,,,60.0,9.23,37.8,8.71,31.0,0.00522418,-0.1250046,45.0,1.579196802756361,9.233353370153191,3.692580809822094e-10,0.24342068829268584,670.0046871276613,10.262507505770085,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP270S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,270.0,247.2,1.62,,,60.0,9.23,37.8,8.71,31.0,0.00453193,-0.124173,43.6,1.5626031133,9.233752302520537,2.8621219946338676e-10,0.2474014600276117,608.56395246418,8.836525119981202,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP270S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,270.0,245.3,1.62,,,60.0,9.23,37.8,8.71,31.0,0.00522418,-0.1250046,45.0,1.579196802756361,9.233353370153191,3.692580809822094e-10,0.24342068829268584,670.0046871276613,10.262507505770085,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP275-20/Wem,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,275.0,253.7,1.61,,,60.0,9.24,38.5,8.74,31.46,0.0048048000000000006,-0.115115,44.88,1.4879198993142435,9.244532882502702,5.314164378446097e-11,0.2910722876776117,593.3328510397884,4.423624933559751,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP275-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,275.0,251.9,1.62,,,60.0,9.27,38.1,8.76,31.4,0.00492237,-0.1219581,44.0,1.5690975102465303,9.273030811112145,2.62644238738779e-10,0.2300176207455937,703.5290962130052,10.851752261985638,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP275S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,275.0,250.0,1.62,,,60.0,9.31,38.0,8.82,31.2,0.00526946,-0.125666,45.0,1.5853081575987544,9.310712915713683,3.6168407309155613e-10,0.2382609645217657,3111.46601459832,9.986789822825836,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP275S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,275.0,251.9,1.62,,,60.0,9.31,38.0,8.82,31.2,0.00457121,-0.12483000000000001,43.6,1.5686610725727286,9.311066406022684,2.8028642543502676e-10,0.24220488251235292,2114.5129629298976,8.562744509497966,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP275S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,275.0,250.0,1.62,,,60.0,9.31,38.0,8.82,31.2,0.00526946,-0.125666,45.0,1.5853081575987544,9.310712915713683,3.6168407309155613e-10,0.2382609645217657,3111.46601459832,9.986789822825836,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP280-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,280.0,256.6,1.62,,,60.0,9.38,38.5,8.86,31.6,0.004980780000000001,-0.1232385,44.0,1.5823126204929927,9.383359058053545,2.5277820784353685e-10,0.24679330301005098,689.1580090306815,10.405050505546969,-0.435,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP280S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,280.0,254.7,1.62,,,60.0,9.4,38.2,8.92,31.4,0.0053203999999999994,-0.1263274,45.0,1.5940939646656536,9.400002603313062,3.6806906946164826e-10,0.23253226869058063,839972.8486981966,10.052807494523917,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP280S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,280.0,256.6,1.62,,,60.0,9.4,38.2,8.92,31.4,0.0046153999999999995,-0.12548700000000002,43.6,1.5765937820446692,9.400002649280607,2.8210416519706997e-10,0.23661712996943085,839825.6318911433,8.529136648447635,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP280S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,280.0,254.7,1.62,,,60.0,9.4,38.2,8.92,31.4,0.0053203999999999994,-0.1263274,45.0,1.5940939646656536,9.400002603313062,3.6806906946164826e-10,0.23253226869058063,839972.8486981966,10.052807494523917,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP285-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,285.0,261.3,1.62,,,60.0,9.46,38.9,9.0,31.7,0.005023260000000001,-0.1245189,44.0,1.5913389576068622,9.460002511363022,2.288956263146992e-10,0.2653691714165082,999998.8928559154,9.431441054721995,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP285S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,285.0,259.4,1.62,,,60.0,9.47,38.4,9.0,31.7,0.00536002,-0.1269888,45.0,1.605484849911726,9.485356178623714,3.8868058991919737e-10,0.21415517815143786,999999.9802860019,10.458637760437492,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP285S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,285.0,261.4,1.62,,,60.0,9.47,38.4,9.0,31.7,0.00464977,-0.126144,43.6,1.5882398664144404,9.480738240857038,2.9963680124043625e-10,0.21824989681793935,999999.9802910822,8.983396531200743,-0.4428,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP285S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,285.0,259.4,1.62,,,60.0,9.47,38.4,9.0,31.7,0.00536002,-0.1269888,45.0,1.605484849911726,9.485356178623714,3.8868058991919737e-10,0.21415517815143786,999999.9802860019,10.458637760437492,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP285S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,285.0,263.0,1.63,,,60.0,9.42,39.1,9.05,31.5,0.00406002,-0.1038887,46.6,1.433135558285402,9.42000337036108,1.3343344191797482e-11,0.3271478561205969,914390.048069193,5.092349307039095,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP290-20/Wfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,290.0,266.0,1.62,,,60.0,9.56,39.1,9.09,31.9,0.00507636,-0.1251591,44.0,1.5979619047605231,9.583419391059547,2.2641805051184287e-10,0.27058885979859515,999999.9285223312,9.22278086733479,-0.435,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP290S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,290.0,264.1,1.62,,,60.0,9.54,38.7,9.07,32.0,0.00539964,-0.1279809,45.0,1.6193766156588811,9.557699048299227,3.9952609594912414e-10,0.20745256322006003,999999.9805742452,10.636720459137031,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP290S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,290.0,266.1,1.62,,,60.0,9.54,38.7,9.07,32.0,0.00468414,-0.1271295,43.6,1.601975346163026,9.553055867525117,3.0803179591717993e-10,0.21155723545750982,999999.9805749163,9.159679338696158,-0.4428,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP290S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,290.0,264.1,1.62,,,60.0,9.54,38.7,9.07,32.0,0.00539964,-0.1279809,45.0,1.6193766156588811,9.557699048299227,3.9952609594912414e-10,0.20745256322006003,999999.9805742452,10.636720459137031,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP290S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,290.0,267.8,1.63,,,60.0,9.52,39.3,9.15,31.7,0.00410312,-0.10442009999999999,46.6,1.4414730735424215,9.52000332137361,1.3744449836590794e-11,0.31895907956664366,914254.3935690718,5.255030129890997,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-20/Web,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,267.8,1.61,,,60.0,9.67,39.56,9.15,32.25,0.0044482,-0.11353719999999999,49.63,1.5034078300409468,9.675102035584874,3.5867446667126735e-11,0.3009235422954322,570.3469687523148,5.1114638218674795,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-20/Wew,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,268.9,1.61,,,60.0,9.67,39.56,9.15,32.25,0.004835000000000001,-0.1198668,47.0,1.5589528682199583,9.673495659580515,9.176732857767916e-11,0.2879747068698594,796.6208139986032,7.3010032587569675,-0.404,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,268.7,1.62,,,60.0,9.69,39.3,9.16,32.2,0.0054845399999999996,-0.12996509999999997,45.0,1.6394839102253387,9.69223649727926,3.752390222349652e-10,0.24513378207723976,1062.0838526135333,9.965839097861465,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,270.8,1.62,,,60.0,9.69,39.3,9.16,32.2,0.00475779,-0.12910049999999998,43.6,1.6222705863650497,9.692641176246632,2.9079997554678015e-10,0.24905612152609624,913.7424019416612,8.542628644413334,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,268.7,1.62,,,60.0,9.69,39.3,9.16,32.2,0.0054845399999999996,-0.12996509999999997,45.0,1.6394839102253387,9.69223649727926,3.752390222349652e-10,0.24513378207723976,1062.0838526135333,9.965839097861465,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,272.5,1.63,,,60.0,9.62,39.5,9.25,31.9,0.00414622,-0.1049515,46.6,1.4498082738739497,9.620003272463585,1.4152332506711847e-11,0.31094643064694505,914110.3485112198,5.415692789440872,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP295S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,295.0,272.6,1.65,,,60.0,9.45,39.3,8.86,33.3,0.0053298,-0.10520609999999998,47.3,1.4792670179043779,9.45823206215078,2.675959156559087e-11,0.15388819885782326,176.65603836282298,10.234959644350058,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-20/Web,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,272.5,1.61,,,60.0,9.74,39.72,9.27,32.37,0.0044804,-0.11399639999999998,49.63,1.5052759523785741,9.740003585103334,3.378677044300917e-11,0.301272953958091,818544.1008406491,4.521448104403146,-0.376,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-20/Wew,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,273.6,1.61,,,60.0,9.74,39.72,9.27,32.37,0.00487,-0.12035159999999999,47.0,1.5631329860999594,9.740002744474497,8.972527621019073e-11,0.2817292808906808,999999.9620987818,7.028261245028753,-0.404,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,273.4,1.62,,,60.0,9.72,39.6,9.23,32.5,0.00550152,-0.1309572,45.0,1.6506917376250225,9.733025030995048,3.7114737254165266e-10,0.23938107170998169,999999.9809920616,9.818503400299647,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,275.5,1.62,,,60.0,9.72,39.6,9.23,32.5,0.004772520000000001,-0.130086,43.6,1.6337018727597614,9.720002994171523,2.8881121146624874e-10,0.24346054128793124,790596.0208169436,8.441877807345161,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,273.4,1.62,,,60.0,9.72,39.6,9.23,32.5,0.00550152,-0.1309572,45.0,1.6506917376250225,9.733025030995048,3.7114737254165266e-10,0.23938107170998169,999999.9809920616,9.818503400299647,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,277.2,1.63,,,60.0,9.72,39.7,9.35,32.1,0.004189320000000001,-0.1054829,46.6,1.458141226547297,9.720003223624627,1.4567003017577404e-11,0.30310418164005426,913958.4707199802,5.574378516064849,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP300S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,300.0,277.4,1.65,,,60.0,9.55,39.5,8.96,33.5,0.005386200000000001,-0.1057415,47.3,1.4869694825457656,9.557847791788271,2.714718934996548e-11,0.14927000198621465,181.6470879523484,10.266755335958011,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP305S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,305.0,278.1,1.62,,,60.0,9.8,39.8,9.3,32.8,0.0055468,-0.13161859999999997,45.0,1.662935036162727,9.800002846150324,3.9536591123243555e-10,0.2217517546633889,763832.0704527728,10.318650859475602,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP305S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,305.0,280.2,1.62,,,60.0,9.8,39.8,9.3,32.8,0.0048118,-0.130743,43.6,1.644944329647229,9.800120921666993,3.042489217381682e-10,0.22579324247405305,18299.363842252595,8.826766747147868,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP305S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,305.0,278.1,1.62,,,60.0,9.8,39.8,9.3,32.8,0.0055468,-0.13161859999999997,45.0,1.662935036162727,9.800002846150324,3.9536591123243555e-10,0.2217517546633889,763832.0704527728,10.318650859475602,-0.4466,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP305S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,305.0,282.0,1.63,,,60.0,9.82,39.9,9.45,32.3,0.004232420000000001,-0.1060143,46.6,1.4664719955764776,9.820003174851408,1.4988471108786068e-11,0.2954268507675366,913799.0843604964,5.731127196691272,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP305S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,305.0,282.1,1.65,,,60.0,9.65,39.7,9.06,33.7,0.0054426,-0.10627690000000001,47.3,1.4946767853237297,9.657475564717187,2.7538406892535545e-11,0.14475202457757871,186.85639118571743,10.298944086078125,-0.3392,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP310-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,310.0,282.4,1.93,,,72.0,8.96,44.9,8.5,36.5,0.005832960000000002,-0.145925,44.6,1.859864754322133,8.970794908842445,2.939618679335047e-10,0.34332484210012587,999999.9841360726,10.299798191982582,-0.4391,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP310S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,310.0,282.9,1.62,,,60.0,9.87,40.2,9.37,33.1,0.00558642,-0.13294140000000002,45.0,1.6785639241477925,9.877681436055077,3.9238818523090934e-10,0.22599917909411826,999999.9815262496,10.18151463664051,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP310S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,310.0,285.0,1.62,,,60.0,9.87,40.2,9.37,33.1,0.0048461699999999995,-0.132057,43.6,1.6607892877799724,9.870003003778866,3.0343197515888016e-10,0.2301008489901856,756302.9202827741,8.740094049329226,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP310S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,310.0,282.9,1.62,,,60.0,9.87,40.2,9.37,33.1,0.00558642,-0.13294140000000002,45.0,1.6785639241477925,9.877681436055077,3.9238818523090934e-10,0.22599917909411826,999999.9815262496,10.18151463664051,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP310S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,310.0,286.7,1.63,,,60.0,9.91,40.1,9.55,32.5,0.00427121,-0.10654570000000001,46.6,1.475434311718687,9.910003072160867,1.5582107888188198e-11,0.28361336534505455,914890.0079535071,5.9863185384631095,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP310S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,310.0,288.3,1.73,,,60.0,9.46,41.3,8.86,35.0,0.005136780000000001,-0.11010579999999999,45.5,1.555284560160708,9.468642733336901,2.709284998797306e-11,0.16069577931805737,175.89135531437103,10.82751601185762,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP310S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,310.0,288.9,1.69,,,60.0,9.87,39.8,9.37,33.1,0.00448098,-0.12708139999999998,43.1,1.5377292914628005,9.872457490116586,5.647116527576378e-11,0.21312836566898127,855.9859473483768,-2.2214407539941066,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP315-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,315.0,287.1,1.93,,,72.0,9.02,45.1,8.56,36.8,0.00587202,-0.146575,44.6,1.8717402589335042,9.030875415087772,3.0995956764350717e-10,0.32372488394142906,999999.9843570669,10.713681487853231,-0.4391,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP315S-20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,315.0,287.6,1.62,,,60.0,9.92,40.6,9.43,33.4,0.005614719999999999,-0.1342642,45.0,1.694382136776057,9.941708872933265,3.900282263556942e-10,0.23044545759605933,999999.9817867901,10.07130227117853,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP315S-20/Wfm,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,315.0,289.7,1.62,,,60.0,9.92,40.6,9.43,33.4,0.004870719999999999,-0.13337100000000002,43.6,1.6776637693389533,9.92000308100583,3.0650956802187533e-10,0.23455075435174577,755415.2095453847,8.784267530181312,-0.4428,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP315S-20/Wfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,315.0,287.6,1.62,,,60.0,9.92,40.6,9.43,33.4,0.005614719999999999,-0.1342642,45.0,1.694382136776057,9.941708872933265,3.900282263556942e-10,0.23044545759605933,999999.9817867901,10.07130227117853,-0.4466,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP315S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,315.0,291.5,1.63,,,60.0,10.0,40.3,9.64,32.7,0.0043100000000000005,-0.1070771,46.6,1.4837351493084932,10.000003024779264,1.5997306990254632e-11,0.2767191862233925,914867.0986595225,6.134754167127923,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP315S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,315.0,293.0,1.73,,,60.0,9.55,41.5,8.95,35.2,0.005185650000000001,-0.11063900000000002,45.5,1.56300951575297,9.558276676279451,2.7459058404729296e-11,0.15616529086271716,180.1905119016498,10.860620917409104,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP315S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,315.0,293.6,1.69,,,60.0,9.95,40.1,9.44,33.4,0.0045173,-0.1280393,43.1,1.5510781170658274,9.95287763568422,5.85713310498649e-11,0.2067427880417301,714.8545133233855,-1.994191712987097,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP320-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,320.0,291.8,1.93,,,72.0,9.11,45.4,8.61,37.2,0.00593061,-0.14755000000000001,44.6,1.89160968605331,9.112292107764786,3.4232362882190735e-10,0.30153819722205866,1198.4664776662048,11.53944924280517,-0.4391,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP320S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,320.0,296.2,1.63,,,60.0,10.09,40.5,9.73,32.9,0.00434879,-0.10760850000000001,46.6,1.4920346195388328,10.09000297744122,1.641867778504423e-11,0.2699500088711365,914836.9062358185,6.281510513827642,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP320S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,320.0,297.8,1.73,,,60.0,9.64,41.7,9.04,35.4,0.005234520000000001,-0.11117220000000001,45.5,1.5707379663101,9.647921145960153,2.7828110109273222e-11,0.1517237898474725,184.64718986209505,10.893895455358201,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP320S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,320.0,298.4,1.69,,,60.0,10.01,40.4,9.52,33.6,0.00454454,-0.12899719999999998,43.1,1.5594806694762098,10.011318481918758,5.6046597497040173e-11,0.21340412336309736,1620.1778500561127,-2.3985223376509746,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP325-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,325.0,296.5,1.93,,,72.0,9.19,45.6,8.7,37.4,0.005982690000000001,-0.1482,44.6,1.899332533913713,9.191195127657979,3.433147615599912e-10,0.2955690222429758,2272.7957103407566,11.48073885839608,-0.4391,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP325S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,325.0,301.0,1.63,,,60.0,10.18,40.7,9.82,33.1,0.00438758,-0.10813990000000001,46.6,1.500332755150007,10.180002930142887,1.6846224151739924e-11,0.26330237455489064,914799.7844036415,6.426617421185264,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP325S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,325.0,302.6,1.73,,,60.0,9.73,41.9,9.13,35.6,0.005283390000000001,-0.1117054,45.5,1.5784701500159972,9.737575918384257,2.8200146974544206e-11,0.14736860278714403,189.27032025885552,10.927374612315637,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP325S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,325.0,303.2,1.69,,,60.0,10.08,40.7,9.59,33.9,0.00457632,-0.1299551,43.1,1.572068671654508,10.081138844540812,5.739927918229155e-11,0.20743500865316442,1836.023389196733,-2.266540433735232,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP330-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,330.0,301.1,1.93,,,72.0,9.22,45.8,8.76,37.7,0.006002220000000001,-0.14884999999999998,44.6,1.9093234864150002,9.234273441979038,3.5297040497137e-10,0.2775422866710789,999999.9849924184,11.682295000928258,-0.4391,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP330S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,330.0,303.6,1.93,,,72.0,9.24,45.8,8.76,37.7,0.0049896,-0.14115559999999996,44.0,1.8396650139465194,9.241611108189382,1.4201869481478614e-10,0.29416620819441386,1687.0974847748942,9.60174927714644,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP330S-A20/Wfb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,330.0,305.8,1.63,,,60.0,10.27,40.9,9.91,33.3,0.00442637,-0.10867129999999998,46.6,1.508629587605613,10.270002882880908,1.7279949199465406e-11,0.25677295139875367,914755.973292533,6.570103950459508,-0.3535,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP330S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,330.0,307.3,1.73,,,60.0,9.82,42.1,9.22,35.8,0.005332260000000001,-0.11223860000000001,45.5,1.5862059453003254,9.8272407837525,2.8575140828656318e-11,0.14309724451082687,194.0694539474924,10.961038516375787,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP330S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,330.0,308.0,1.69,,,60.0,10.16,41.0,9.66,34.2,0.00461264,-0.130913,43.1,1.5854106485743296,10.161584848683233,5.948328472029257e-11,0.2012402066467556,1290.0920591164763,-2.0447947683240764,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP335-24/Vem,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,335.0,309.2,1.93,,,72.0,9.3,46.45,8.82,37.98,0.004836000000000001,-0.1388855,44.88,1.7934309047194554,9.302423670724652,5.232368327816921e-11,0.3459020269394099,1327.2798011130783,4.228460105040065,-0.383,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP335-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,335.0,305.8,1.93,,,72.0,9.3,46.1,8.82,38.0,0.006054300000000001,-0.149825,44.6,1.9237645856627354,9.30025177732791,3.6399308222587626e-10,0.2702530539011383,9982.484155993381,11.896590819784134,-0.4391,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP335S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,335.0,308.3,1.93,,,72.0,9.33,46.0,8.84,37.9,0.0050382000000000005,-0.14177199999999998,44.0,1.8492093236020721,9.332066959140867,1.4622995734593328e-10,0.2878635418088645,1299.381015291844,9.77720822427777,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP335S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,335.0,312.1,1.73,,,60.0,9.91,42.3,9.31,36.0,0.0053811300000000005,-0.11277179999999999,45.5,1.5939452410105812,9.91691553919203,2.895306894234847e-11,0.13890732694683827,199.0548501966101,10.994869183047737,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP335S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,335.0,312.8,1.69,,,60.0,10.35,41.2,9.75,34.4,0.0046989,-0.1315516,43.1,1.6015741594267747,10.357332239048255,6.867210639127111e-11,0.19335090406732497,272.92916227161095,-1.0167775131842502,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP340-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,340.0,310.5,1.93,,,72.0,9.4,46.5,8.93,38.1,0.0061194000000000005,-0.151125,44.6,1.9338864428250457,9.417517387830395,3.399309687517711e-10,0.29939624217002914,999999.985243825,11.16618113985966,-0.4391,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP340S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,340.0,313.1,1.93,,,72.0,9.41,46.2,8.93,38.1,0.0050814,-0.1423884,44.0,1.8566791676689576,9.411029577179065,1.4662272720862548e-10,0.2822529245159465,2579.700946002216,9.719345337737046,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP340S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,340.0,316.9,1.73,,,60.0,10.0,42.5,9.4,36.2,0.005430000000000001,-0.113305,45.5,1.6016879273840106,10.006599986873036,2.933390602635343e-11,0.13479654889781142,204.2376027107108,11.028849114819785,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP340S-A60/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,340.0,317.6,1.69,,,60.0,10.44,41.4,9.82,34.6,0.00473976,-0.13219019999999998,43.1,1.6114484560287263,10.4481896768571,7.149664242845417e-11,0.18850236581711358,240.298216216177,-0.7580831431574077,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP345-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,345.0,315.2,1.93,,,72.0,9.5,46.7,9.04,38.2,0.006184500000000001,-0.15177500000000002,44.6,1.9440983249753534,9.500002747549535,3.510362572186959e-10,0.2891003515100857,999999.9808190335,11.375611327347368,-0.4391,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP345S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,345.0,317.8,1.93,,,72.0,9.52,46.3,9.04,38.2,0.005140799999999999,-0.14269659999999998,44.0,1.8589324739487194,9.52000625765702,1.4513103679723447e-10,0.27776331615095196,422602.2296483476,9.52018079925256,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP345S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,345.0,321.7,1.73,,,60.0,10.08,42.7,9.48,36.4,0.00547344,-0.11383820000000001,45.5,1.6094846848908688,10.08631026326223,2.971084636048806e-11,0.130878522134497,209.06505103769513,11.070105689837725,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP350-24/Vfw,Wuxi Suntech Power Co Ltd,Multi-c-Si,0,350.0,319.9,1.93,,,72.0,9.59,46.9,9.12,38.4,0.006243090000000001,-0.152425,44.6,1.949682535241806,9.618516520225677,3.436102389098889e-10,0.2992501667773057,999999.9745240421,11.073972006404649,-0.4391,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP350S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,350.0,322.5,1.93,,,72.0,9.56,46.4,9.1,38.5,0.0051624,-0.1430048,44.0,1.8697953050653353,9.560003167480598,1.5966088828041362e-10,0.24894222936975252,751447.7461773815,10.328596767920738,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP350S-A21/Wfhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,350.0,326.5,1.73,,,60.0,10.17,42.9,9.57,36.6,0.00552231,-0.1143714,45.5,1.6172331485787343,10.176013056214762,3.009717971291147e-11,0.12691453244041745,214.6530411009074,11.104205792166024,-0.3412,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP355S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,355.0,327.3,1.93,,,72.0,9.58,47.5,9.13,38.9,0.005173199999999999,-0.146395,44.0,1.903760072387364,9.58000291523688,1.3978017003068162e-10,0.3042490495055191,999998.0563534402,9.133680300819767,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP355S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,355.0,328.5,1.95,,,72.0,9.65,47.4,9.27,38.3,0.0039372,-0.1257996,46.1,1.7393176214216182,9.650003792713697,1.4096231255344705e-11,0.37474965962006407,953519.3626083204,5.505592581666398,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP355S-B60/Wnhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,355.0,331.4,1.82,,,60.0,11.08,41.3,10.51,33.8,0.007467920000000001,-0.11625949999999999,43.2,1.5987418878060913,11.082655311072475,6.66908404780848e-11,0.254018124528891,1059.959109625431,11.16681125367441,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP360S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,360.0,332.0,1.93,,,72.0,9.66,47.7,9.18,39.2,0.0052164,-0.1470114,44.0,1.9123164748062798,9.660003854191583,1.4194484251383536e-10,0.30137425042204835,755452.7127088273,9.19574439364287,-0.414,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP360S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,360.0,333.2,1.95,,,72.0,9.74,47.6,9.36,38.5,0.003973920000000001,-0.1263304,46.1,1.7476706010896648,9.740003745005836,1.4454470139148705e-11,0.3665262188910063,953284.3853696659,5.6409957143563165,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP360S-B60/Wnhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,360.0,336.2,1.82,,,60.0,11.15,41.5,10.59,34.0,0.0075151,-0.1168225,43.2,1.6063866847452126,11.151507243277342,6.710118392710772e-11,0.24971156911102335,1847.2692831374839,11.160560710349037,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP365S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,365.0,336.7,1.93,,,72.0,9.71,47.9,9.24,39.5,0.0052434000000000005,-0.14762779999999998,44.0,1.92335357360573,9.721940878205329,1.485592951982486e-10,0.28370925048214457,999999.9861586277,9.541771059588672,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP365S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,365.0,338.0,1.95,,,72.0,9.82,47.8,9.44,38.7,0.004006560000000001,-0.1268612,46.1,1.755990813721054,9.820003698837876,1.4795726423273403e-11,0.3590392187159798,953232.8591782526,5.770909781596249,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP365S-B60/Wnhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,365.0,341.0,1.82,,,60.0,11.22,41.7,10.68,34.2,0.007562280000000001,-0.1173855,43.2,1.6140377871100615,11.220004328233308,6.755129283530156e-11,0.2453763124568138,636129.253602014,11.157966857761727,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP370S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,370.0,341.5,1.93,,,72.0,9.78,48.1,9.32,39.7,0.0052812,-0.1482442,44.0,1.9346458444176762,9.780002609071582,1.5585472707928136e-10,0.2667258627672003,999999.2063943035,9.912388150920878,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP370S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,370.0,342.7,1.95,,,72.0,9.9,48.0,9.52,38.9,0.004039200000000001,-0.127392,46.1,1.7643094699880142,9.90000365272331,1.5141506464173605e-11,0.35167658432488813,953175.2322954416,5.899535975250681,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP370S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,370.0,344.5,1.99,,,72.0,10.05,47.8,9.12,40.6,0.0032662500000000005,-0.1258096,45.5,1.7860040074214425,10.072285044467643,2.2467800230343878e-11,0.16704540204522558,75.33331603000697,10.481961030595768,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP370S-B60/Wnhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,370.0,345.8,1.82,,,60.0,11.29,41.9,10.76,34.4,0.00760946,-0.11794849999999998,43.2,1.623333945636469,11.290004300440746,6.967589700101727e-11,0.24090660789441073,632499.5698948535,11.380881482322765,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP375S-24/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,375.0,346.2,1.93,,,72.0,9.85,48.3,9.4,39.9,0.005319,-0.14886059999999998,44.0,1.9447337300686982,9.85000251367544,1.6112540189447506e-10,0.25515205874101066,999999.7778607695,10.144149195001354,-0.414,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP375S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,375.0,347.5,1.95,,,72.0,9.97,48.2,9.6,39.1,0.004067760000000001,-0.12792280000000003,46.1,1.7733802752030967,9.970003545792624,1.5656173863437785e-11,0.3394369221810185,954446.6012360414,6.126276396478613,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP375S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,375.0,349.3,1.99,,,72.0,10.12,48.0,9.2,40.8,0.0032890000000000003,-0.126336,45.5,1.7924409162642476,10.141281141415087,2.232315699594348e-11,0.1633037006408302,77.65718111039477,10.354892449314,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP375S-B60/Wnhb,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,375.0,350.6,1.82,,,60.0,11.36,42.1,10.84,34.6,0.007656639999999999,-0.1185115,43.2,1.6326281749146987,11.36000427162938,7.184212125694039e-11,0.2365031656918171,629002.3785413279,11.601406904317031,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP380S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,380.0,352.2,1.95,,,72.0,10.04,48.4,9.67,39.3,0.00409632,-0.1284536,46.1,1.7816652231494141,10.040003501241102,1.599052266846475e-11,0.3328684440170264,954541.904216131,6.247946744006814,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP380S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,380.0,354.0,1.99,,,72.0,10.19,48.2,9.27,41.0,0.00331175,-0.12686240000000001,45.5,1.779845325321784,10.211512987896693,1.6625837356813397e-11,0.1642880990498692,77.81790885475755,7.699099603446665,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP385S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,385.0,357.0,1.95,,,72.0,10.11,48.6,9.75,39.5,0.00412488,-0.12898440000000003,46.1,1.7907303182038998,10.110003393197509,1.6523381879992038e-11,0.3207591979774909,955722.1742064479,6.470644258294943,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP385S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,385.0,358.8,1.99,,,72.0,10.26,48.4,9.35,41.2,0.0033345000000000002,-0.1273888,45.5,1.784751721722792,10.280595794817408,1.6154033966501973e-11,0.16100241887890857,80.20495612409755,7.381979425086643,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP390S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,390.0,361.7,1.95,,,72.0,10.18,48.8,9.83,39.7,0.00415344,-0.1295152,46.1,1.7997922246063471,10.180003283883678,1.7067917118178165e-11,0.3086521990594484,956840.9882737007,6.6911034967283785,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP390S-A72/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,390.0,363.9,2.01,,,72.0,10.12,49.0,9.55,40.8,0.004594480000000001,-0.15645699999999998,43.1,1.9002161783524452,10.126354147256425,6.326632942465255e-11,0.24914720067083385,396.80692010098596,-1.4977676251362664,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP390S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,390.0,363.6,1.99,,,72.0,10.33,48.6,9.43,41.4,0.0033572500000000004,-0.1279152,45.5,1.8128772109088722,10.34881128886611,2.2238395341366973e-11,0.15212490677078985,83.53761420973623,10.120657523016245,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP395S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,395.0,366.5,1.95,,,72.0,10.25,49.0,9.9,39.9,0.004182000000000001,-0.13004600000000002,46.1,1.8080718513858434,10.250003239361224,1.7419690985177255e-11,0.30239944722109785,956876.3328417074,6.808291658291916,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP395S-A72/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,395.0,368.7,2.01,,,72.0,10.19,49.2,9.62,41.1,0.00462626,-0.1570956,43.1,1.9109351229196812,10.195881545390199,6.631346076782714e-11,0.23243490950701315,402.7022893248708,-1.1790857661474947,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP395S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,395.0,368.4,1.99,,,72.0,10.4,48.8,9.5,41.6,0.0033800000000000006,-0.1284416,45.5,1.8203929566870252,10.418274556737938,2.242304777682519e-11,0.14831432552383703,84.40527505749402,10.131586777982351,-0.3396,N,2025.7.3,6/23/2025,4.0,bootstrapping +Wuxi Suntech Power Co Ltd STP400S-A24U/Vfw,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,400.0,371.3,1.95,,,72.0,10.33,49.2,9.98,40.1,0.00421464,-0.13057680000000002,46.1,1.8163770409564737,10.330003193391196,1.7799698875209054e-11,0.29574984051629766,956715.9462283384,6.927830179859212,-0.3555,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP400S-A72/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,400.0,373.5,2.01,,,72.0,10.26,49.5,9.69,41.3,0.0046580400000000004,-0.15805349999999999,43.1,1.920910209950488,10.265771498515031,6.532394436128496e-11,0.23837572976413618,423.7608381010788,-1.3550728707284696,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP400S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,400.0,373.2,1.99,,,72.0,10.47,49.0,9.57,41.8,0.003402750000000001,-0.128968,45.5,1.8279116872876089,10.48774734820027,2.2608812770010166e-11,0.14455856210042173,85.2819322952612,10.14276991028259,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP405S-A72/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,405.0,378.3,2.01,,,72.0,10.32,49.8,9.75,41.5,0.00468528,-0.1590114,43.1,1.9309442286930714,10.325675380487684,6.43446938787769e-11,0.2444586606022622,444.51882293816027,-1.5230177330428074,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP405S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,405.0,377.9,1.99,,,72.0,10.54,49.2,9.65,42.0,0.0034254999999999997,-0.1294944,45.5,1.8038778296803568,10.557996198036461,1.4271012905302174e-11,0.1484168324894079,86.92466114126282,6.060794307773379,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP410S-A72/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,410.0,383.1,2.01,,,72.0,10.38,50.1,9.82,41.8,0.00471252,-0.15996929999999998,43.1,1.9424779133129813,10.384775999033259,6.473000916921305e-11,0.23882398099125005,519.0522426396667,-1.526361267737516,-0.3788,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP410S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,410.0,382.7,1.99,,,72.0,10.61,49.4,9.72,42.2,0.00344825,-0.1300208,45.5,1.8419459877308062,10.626383960571626,2.267535932491176e-11,0.13750101039308033,89.04353232024332,10.041217369862752,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP415S-A72U/Vfh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,415.0,387.5,1.99,,,72.0,10.68,49.6,9.79,42.4,0.003471,-0.1305472,45.5,1.8494768549334857,10.695893388835385,2.2864233478714194e-11,0.13390284748392126,89.97970341295593,10.054100198822603,-0.3396,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP425S-B72/Vnh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,425.0,396.7,2.18,,,72.0,11.03,49.3,10.48,40.6,0.00743422,-0.13877949999999997,43.2,1.9131439527302476,11.031439843422156,7.084955696102789e-11,0.27669412368002905,2119.6311822532284,11.748970303621768,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP430S-B72/Vnh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,430.0,401.5,2.18,,,72.0,11.09,49.5,10.55,40.8,0.00747466,-0.13934249999999998,43.2,1.9206247755298367,11.090446120627426,7.106412910243101e-11,0.27252668724174006,6774.6762115524325,11.72253832985782,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP435S-B72/Vnh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,435.0,406.3,2.18,,,72.0,11.16,49.7,10.61,41.0,0.00752184,-0.1399055,43.2,1.929833287779945,11.16102799124803,7.28496486134871e-11,0.26802474555028777,2909.710412982423,11.893019428052531,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP440S-B72/Vnh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,440.0,411.1,2.18,,,72.0,11.23,49.9,10.68,41.2,0.007569020000000001,-0.1404685,43.2,1.866710648235963,11.230112914142936,2.7603601167722432e-11,0.2780775949614765,27656.541633959812,3.369717118948399,-0.3754,N,2025.7.3,6/23/2025,4.0,first_pass +Wuxi Suntech Power Co Ltd STP445S-B72/Vnh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,445.0,415.9,2.18,,,72.0,11.29,50.1,10.75,41.4,0.00760946,-0.14103149999999998,43.2,1.9457737635764378,11.291804332043654,7.421618610378759e-11,0.25959776787723093,999999.9472949086,11.950145616635265,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +Wuxi Suntech Power Co Ltd STP450S-B72/Vnh,Wuxi Suntech Power Co Ltd,Mono-c-Si,0,450.0,420.7,2.18,,,72.0,11.36,50.3,10.82,41.6,0.007656639999999999,-0.14159449999999998,43.2,1.9542971750206481,11.36449522382689,7.544150416986332e-11,0.255261749955157,999999.9476024729,12.04060921559822,-0.3754,N,2025.7.3,6/23/2025,2.0,first_pass +WYONE TRADING INC SM355-M660NH-BB,WYONE TRADING INC,Mono-c-Si,0,355.0,331.3,1.8,,,60.0,11.14,40.4,10.57,33.6,0.005302640000000001,-0.10613079999999998,45.6,1.473281921991184,11.145387633112634,1.362471094732904e-11,0.20981556708502197,433.8352972095964,5.008578423496884,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM360-M660NH-BB,WYONE TRADING INC,Mono-c-Si,0,360.0,336.1,1.8,,,60.0,11.24,40.6,10.66,33.8,0.00535024,-0.1066562,45.6,1.4816311464731258,11.245759911271026,1.4009413512411609e-11,0.20532944544121465,400.6837743157577,5.172555015029031,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM365-M660NH-BB,WYONE TRADING INC,Mono-c-Si,0,365.0,340.9,1.8,,,60.0,11.33,40.8,10.74,34.0,0.005393080000000001,-0.10718159999999999,45.6,1.4900134809289745,11.336148031356695,1.4396076855716024e-11,0.20109307987581124,370.5876697902402,5.339875345190043,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM370-M660NH-BB,WYONE TRADING INC,Mono-c-Si,0,370.0,345.7,1.8,,,60.0,11.42,41.0,10.82,34.2,0.00543592,-0.107707,45.6,1.498395366915929,11.426518712918089,1.4789209792441286e-11,0.1969197696451449,344.97972458377575,5.505503606241051,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM375-M660NH-BB,WYONE TRADING INC,Mono-c-Si,0,375.0,350.5,1.8,,,60.0,11.51,41.2,10.91,34.4,0.00547876,-0.1082324,45.6,1.5061200464221607,11.51617749277998,1.5024945715303958e-11,0.19287948793638807,359.37604516910204,5.572316050950646,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM390-M754SH-BB,WYONE TRADING INC,Mono-c-Si,0,390.0,359.3,1.94,,,54.0,13.56,36.7,12.79,30.5,0.00736308,-0.10918250000000002,45.37,1.4642276408412627,13.567627710675092,1.7471614057812704e-10,0.13739320176869668,244.24784909623122,11.993539884020604,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM400-M754SH-BB,WYONE TRADING INC,Mono-c-Si,0,400.0,368.8,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007439099999999999,-0.1103725,45.37,1.480294688867116,13.705743463998656,1.7725662020202566e-10,0.13160420151602864,313.9181674412768,12.023035173395055,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM405-M754SH-BB,WYONE TRADING INC,Mono-c-Si,0,405.0,373.5,1.94,,,54.0,13.77,37.3,13.03,31.1,0.0074771099999999995,-0.1109675,45.37,1.4883266455972926,13.774858282217933,1.7852278760185006e-10,0.12876427701722212,364.96114223748964,12.037274463906064,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM410-M754SH-BB,WYONE TRADING INC,Mono-c-Si,0,410.0,378.3,1.94,,,54.0,13.84,37.5,13.1,31.3,0.00751512,-0.1115625,45.37,1.4969436300951489,13.844611455842742,1.8139524561662978e-10,0.1258810638243036,377.79642901378406,12.134918135103467,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM430-M672NH-WB,WYONE TRADING INC,Mono-c-Si,0,430.0,401.5,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00491241,-0.1282545,45.7,1.7822749127684092,11.197622941581903,9.619271457369746e-12,0.3198069719849507,469.4565749366308,3.5168948825623616,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM435-M672NH-WB,WYONE TRADING INC,Mono-c-Si,0,435.0,406.3,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00494314,-0.12877270000000002,45.7,1.789972206459299,11.267298430122242,9.75734480831969e-12,0.3152333088639414,486.3411758535138,3.5834125788860685,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM440-M672NH-WB,WYONE TRADING INC,Mono-c-Si,0,440.0,411.1,2.15,,,72.0,11.33,49.9,10.74,41.0,0.00497387,-0.1292909,45.7,1.7976698099741357,11.336980980561282,9.89637143342542e-12,0.31071959460617027,504.29205558800237,3.649427556698969,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM445-M672NH-WB,WYONE TRADING INC,Mono-c-Si,0,445.0,415.9,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0050046000000000005,-0.1298091,45.7,1.7951160234162518,11.400007192237391,8.632779720938824e-12,0.30815851925527477,488447.83020992915,2.419494898633385,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM450-M672NH-WB,WYONE TRADING INC,Mono-c-Si,0,450.0,420.7,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00503094,-0.1303273,45.7,1.8031391296985968,11.46001282194526,8.794033877456291e-12,0.30396324043616585,271677.3853751143,2.5303995683389298,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM520-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,520.0,486.7,2.56,,,72.0,13.53,49.0,12.79,40.7,0.0059532,-0.118286,45.84,1.7462563589841997,13.54160083361372,8.694155949495618e-12,0.22143938147310896,258.26375429687414,8.565436880412744,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM525-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,525.0,491.5,2.56,,,72.0,13.59,49.2,12.85,40.9,0.005979599999999999,-0.11876880000000001,45.84,1.7145289226370168,13.602576390443899,4.619933196014363e-12,0.22525277540592395,243.40729854105166,3.043742714820175,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM530-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,530.0,496.3,2.56,,,72.0,13.65,49.4,12.91,41.1,0.006006,-0.1192516,45.84,1.7615037898086636,13.660993575081516,8.914922631050859e-12,0.21530738881063527,267.3330419180575,8.708043673062718,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM535-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,535.0,501.1,2.56,,,72.0,13.71,49.6,12.96,41.3,0.006032399999999999,-0.11973440000000002,45.84,1.7697535652342493,13.721457500828324,9.107932581062545e-12,0.21224505209899505,253.97157795492197,8.862287962876529,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM540-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,540.0,505.9,2.56,,,72.0,13.77,49.8,13.02,41.5,0.006058799999999999,-0.1202172,45.84,1.7773760135570378,13.781156398124594,9.220236719014613e-12,0.2092484072237751,258.2688915327224,8.931653280901935,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM545-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,545.0,510.7,2.56,,,72.0,13.83,50.0,13.07,41.7,0.0060852,-0.1207,45.84,1.7856270181716236,13.841597217384084,9.417168281090002e-12,0.20623499946794324,245.94089747265346,9.083940628232718,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +WYONE TRADING INC SM550-M772SH-TB,WYONE TRADING INC,Mono-c-Si,0,550.0,515.6,2.56,,,72.0,13.89,50.2,13.13,41.9,0.006111599999999999,-0.12118280000000001,45.84,1.7932485065875219,13.901295983953075,9.5311226804232e-12,0.20329173349191756,249.97576125144317,9.15173694717144,-0.3197,N,2025.7.3,6/23/2025,4.0,bootstrapping +Xuzhou Futuresolar Co Ltd FSM-54HTB-400M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,400.0,371.9,1.89,,,54.0,13.51,37.8,13.01,30.8,0.005187839999999999,-0.10206000000000001,45.44,1.4033487375937899,13.510002930996071,2.7082204247158944e-11,0.18244844508138397,840822.0314036612,6.422870308551333,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-405M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,405.0,376.7,1.89,,,54.0,13.56,38.0,13.08,31.0,0.00520704,-0.10260000000000001,45.44,1.4125022503110618,13.560002804244236,2.809327636252105e-11,0.17435737803478982,842953.7311381709,6.706966521684733,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-410M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,410.0,381.5,1.89,,,54.0,13.61,38.2,13.15,31.2,0.005226239999999999,-0.10314000000000002,45.44,1.4216614352341188,13.610002674774494,2.9132456245253536e-11,0.16610259439743935,845011.6253656002,6.9890190852671505,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-415M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,415.0,386.3,1.89,,,54.0,13.66,38.4,13.22,31.4,0.00524544,-0.10368000000000001,45.44,1.4308263578507658,13.660002542261116,3.020029581620843e-11,0.1576662942158274,846994.382456797,7.269070562326897,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-420M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,420.0,391.1,1.89,,,54.0,13.71,38.6,13.3,31.6,0.005264639999999999,-0.10422000000000001,45.44,1.4404634415032,13.710002358886657,3.1570150962126454e-11,0.14618387996106402,849445.6729824609,7.622630255168303,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-425M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,425.0,395.9,1.89,,,54.0,13.78,38.8,13.37,31.8,0.00529152,-0.10475999999999999,45.44,1.4487338598434618,13.780002312953613,3.220847107871005e-11,0.1426955252263738,849957.5867047001,7.752529450349389,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-430M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,430.0,400.7,1.89,,,54.0,13.86,39.0,13.44,32.0,0.00532224,-0.1053,45.44,1.456551079882908,13.860002313666739,3.2604324715658285e-11,0.14189229534175832,849818.4638704011,7.808510339228425,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-435M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,435.0,405.5,1.89,,,54.0,13.94,39.2,13.51,32.2,0.0053529599999999995,-0.10584000000000002,45.44,1.4643680049828933,13.940002313739495,3.300150150679331e-11,0.14106079423223752,849688.7332586806,7.863873140202715,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-440M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,440.0,410.3,1.89,,,54.0,14.01,39.4,13.59,32.4,0.0053798399999999994,-0.10638000000000002,45.44,1.473162346182616,14.010083083186164,3.3971541564398235e-11,0.18553028471024588,31285.307416653784,8.073237229656439,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Xuzhou Futuresolar Co Ltd FSM-54HTB-445M,Xuzhou Futuresolar Co Ltd,Mono-c-Si,0,445.0,415.1,1.89,,,54.0,14.09,39.6,13.66,32.6,0.005410559999999999,-0.10692000000000002,45.44,1.4809215032803427,14.09000222147299,3.434223463947761e-11,0.13413565590751028,850584.4351203807,8.117987101160724,-0.363,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL170P-23b,Yingli Energy (China),Multi-c-Si,0,170.0,154.2,1.28403,1.297,0.99,48.0,8.1,29.0,7.39,23.0,0.00361098,-0.09558399999999999,44.1,1.1997644451973166,8.135172576023784,2.468571804838327e-10,0.3371694219081691,77.64778094261415,8.481736419677421,-0.4486,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL175P-23b,Yingli Energy (China),Multi-c-Si,0,175.0,158.9,1.28403,1.297,0.99,48.0,8.2,29.0,7.61,23.0,0.0036555599999999995,-0.09558399999999999,44.1,1.1889099109562864,8.218676859635856,2.0456533701962418e-10,0.33272900407902595,146.08334341850218,6.687419513695341,-0.4486,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL180P-23b,Yingli Energy (China),Multi-c-Si,0,180.0,163.5,1.28403,1.297,0.99,48.0,8.3,29.5,7.83,23.0,0.00370014,-0.097232,44.1,1.1878507631430832,8.300460447345754,1.3591931738976884e-10,0.39357906396204256,7094.666484798057,3.068943811232497,-0.4486,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL185P-23b,Yingli Energy (China),Multi-c-Si,0,185.0,168.1,1.28403,1.297,0.99,48.0,8.45,29.5,7.87,23.5,0.00376701,-0.097232,44.1,1.210239511785612,8.46521581873279,2.1515967491805376e-10,0.3127887554083049,173.70509758675018,6.852463996894222,-0.4486,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL195P-26b,Yingli Energy (China),Multi-c-Si,0,195.0,173.0,1.4652,1.48,0.99,54.0,8.45,33.6,7.5,26.0,0.0042419,-0.1133328,46.5,1.4513342970954821,8.525548975293137,6.947573454740207e-10,0.46154313488510396,51.62267208992313,14.824386997090457,-0.4861,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL200P-26b,Yingli Energy (China),Multi-c-Si,0,200.0,177.5,1.4652,1.48,0.99,54.0,8.33,33.5,7.6,26.3,0.00418166,-0.1129955,46.5,1.4376184490339656,8.365630343933322,6.075911586725353e-10,0.4049109153800933,94.6639323681465,13.637859469469687,-0.4861,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL205P-26b,Yingli Energy (China),Multi-c-Si,0,205.0,182.1,1.4652,1.48,0.99,54.0,8.22,33.3,7.74,26.5,0.00412644,-0.11232089999999999,46.5,1.4165383644066745,8.222196080332985,5.061146655454562e-10,0.3514098476332542,1315.3404973490342,11.985887612339447,-0.4861,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL210P-26b,Yingli Energy (China),Multi-c-Si,0,210.0,186.7,1.4652,1.48,0.99,54.0,8.15,33.0,7.9,26.6,0.0040913,-0.111309,46.5,1.428594510984037,8.150001468549142,7.570341850114832e-10,0.1800233388765973,999998.8327031031,15.765188985418703,-0.4861,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL220P-29b,Yingli Energy (China),Multi-c-Si,0,220.0,197.4,1.6335,1.65,0.99,60.0,8.15,36.5,7.59,29.0,0.004629200000000001,-0.127385,45.3,1.5456754876062562,8.162942093641917,4.451569475556391e-10,0.3996263653908534,251.6560131566954,7.128712344052457,-0.469,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL225P-29b,Yingli Energy (China),Multi-c-Si,0,225.0,202.0,1.6335,1.65,0.99,60.0,8.28,36.5,7.63,29.5,0.00470304,-0.127385,45.3,1.5705797815443625,8.299556283619983,6.480017290697908e-10,0.3152449612025054,133.47263318114935,10.337295002228746,-0.469,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL230P-29b,Yingli Energy (China),Multi-c-Si,0,230.0,206.6,1.6335,1.65,0.99,60.0,8.4,37.0,7.8,29.5,0.004771200000000001,-0.12913,45.3,1.5725588328832762,8.415805321849325,4.979184026839159e-10,0.37737006962535036,200.55961307357958,7.851209145925391,-0.469,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL235P-29b,Yingli Energy (China),Multi-c-Si,0,235.0,212.3,1.6335,1.65,0.99,60.0,8.54,37.0,7.97,29.5,0.0037405199999999993,-0.12469000000000001,44.8,1.5328786450708183,8.552691365982529,2.7661459043039615e-10,0.3803069252055657,255.90796566444595,6.5377100024516555,-0.4586,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL240P-29b,Yingli Energy (China),Multi-c-Si,0,240.0,217.0,1.6335,1.65,0.99,60.0,8.65,37.5,8.14,29.5,0.0037887000000000003,-0.12637500000000002,44.8,1.5351164834870383,8.653844315484962,2.119834218957636e-10,0.4383613812264099,986.34678062538,4.136915601472476,-0.4586,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL240P-32b,Yingli Energy (China),Multi-c-Si,0,240.0,211.5,1.77408,1.792,0.99,66.0,8.15,40.5,7.45,32.2,0.0032844500000000004,-0.13729500000000003,48.6,1.705232192704653,8.181396474595317,3.7951211152570807e-10,0.4473291786106862,116.11918797741103,9.162570183877778,-0.468,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL245P-29b,Yingli Energy (China),Multi-c-Si,0,245.0,221.6,1.6335,1.65,0.99,60.0,8.63,37.8,8.11,30.2,0.0037799400000000007,-0.127386,44.8,1.5622413427699398,8.636086525946624,2.657899752246183e-10,0.3753271231241067,532.1712390870458,6.081782701945098,-0.4586,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL245P-32b,Yingli Energy (China),Multi-c-Si,0,245.0,216.0,1.77408,1.792,0.99,66.0,8.22,40.8,7.6,32.2,0.0033126600000000007,-0.138312,48.6,1.6998665411395582,8.242012340244255,3.020589752341622e-10,0.48420564436793007,180.81543651162914,7.056535807256059,-0.468,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL250C-30b,Yingli Energy (China),Mono-c-Si,0,250.0,230.3,1.6335,1.65,0.99,60.0,9.1,37.6,8.57,29.5,0.004004,-0.1128,45.0,1.4050351186798302,9.108847636494616,2.1554975701038233e-11,0.4599645071000161,473.0842193986619,-3.020062491780683,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL250P-29b,Yingli Energy (China),Multi-c-Si,0,250.0,226.2,1.6335,1.65,0.99,60.0,8.79,38.4,8.24,30.4,0.0038500199999999996,-0.12940800000000002,44.8,1.580741729694022,8.798576690570801,2.4540015538850483e-10,0.4144720281485034,424.7804018542744,5.2516101026964614,-0.4586,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL250P-32b,Yingli Energy (China),Multi-c-Si,0,250.0,220.6,1.77408,1.792,0.99,66.0,8.33,40.9,7.74,32.3,0.0033569900000000002,-0.138651,48.6,1.7002405230249813,8.347006504862424,2.9185012722127687e-10,0.47548265510828264,232.8974224510441,6.629135395396449,-0.468,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL255C-30b,Yingli Energy (China),Mono-c-Si,0,255.0,235.0,1.6335,1.65,0.99,60.0,9.16,37.9,8.62,29.9,0.0040304,-0.1137,45.0,1.4209035678941362,9.17010936463005,2.3649536792970304e-11,0.43842267559061165,397.25067860907166,-2.3370233855335307,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL255P-29b,Yingli Energy (China),Multi-c-Si,0,255.0,230.9,1.6335,1.65,0.99,60.0,8.88,38.7,8.32,30.6,0.00388944,-0.130419,44.8,1.5923987126592298,8.889228236665778,2.451921096429464e-10,0.41884204825943516,403.0367280209536,5.159513585388263,-0.4586,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL255P-32b,Yingli Energy (China),Multi-c-Si,0,255.0,225.1,1.77408,1.792,0.99,66.0,8.4,41.0,7.85,32.5,0.0033852000000000005,-0.13899000000000003,48.6,1.7029914809271627,8.410986569124558,2.903644751733767e-10,0.45405192858565746,347.1545123737042,6.494554432616546,-0.468,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL260C-30b,Yingli Energy (China),Mono-c-Si,0,260.0,239.7,1.6335,1.65,0.99,60.0,9.22,38.2,8.67,30.3,0.0040568,-0.11460000000000001,45.0,1.4367799276185784,9.231169856648197,2.5901082056786783e-11,0.4171410032818752,344.3231450873401,-1.6635164982507276,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL260P-29b,Yingli Energy (China),Multi-c-Si,0,260.0,235.0,1.6236,1.64,0.99,60.0,8.04,44.6,7.43,35.0,0.00402,-0.14272,46.6,1.7933438481007287,8.065220179569852,1.2383587713422492e-10,0.5892080362744879,187.835019232751,5.669356679156027,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL260P-35b,Yingli Energy (China),Multi-c-Si,0,260.0,232.5,1.9304999999999999,1.95,0.99,72.0,8.04,44.6,7.43,35.0,0.00347328,-0.152978,45.9,1.861628563760217,8.062431722959078,3.089861297597053e-10,0.570584007886104,204.50930636510017,6.147391265208507,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL265C-30b,Yingli Energy (China),Mono-c-Si,0,265.0,244.4,1.6335,1.65,0.99,60.0,9.35,38.28,8.73,30.38,0.004114,-0.11484,45.0,1.4451040932925459,9.36997369642025,2.872057811582605e-11,0.4107492215421043,192.27814447082616,-0.9249856244157931,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL265P-29b,Yingli Energy (China),Multi-c-Si,0,265.0,239.7,1.6236,1.64,0.99,60.0,8.15,44.6,7.5,35.3,0.0040750000000000005,-0.14272,46.6,1.806110589756749,8.178527521012983,1.487417866703866e-10,0.5343799100359254,152.66648985781853,7.142366554100767,-0.43,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL265P-35b,Yingli Energy (China),Multi-c-Si,0,265.0,237.1,1.9304999999999999,1.95,0.99,72.0,8.15,44.6,7.5,35.3,0.0035208,-0.152978,45.9,1.8752944170767953,8.175720015037514,3.7066318419581704e-10,0.5155361665557084,163.35994593397334,7.616656569084154,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL270C-30b,Yingli Energy (China),Mono-c-Si,0,270.0,249.1,1.6335,1.65,0.99,60.0,9.45,38.48,8.82,30.61,0.004157999999999999,-0.11543999999999999,45.0,1.4547485303783356,9.47040336849027,3.0134194823831767e-11,0.39912730569866284,184.859333869148,-0.6228271406830072,-0.377,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL270D-30b,Yingli Energy (China),Mono-c-Si,0,270.0,242.5,1.6236,1.64,0.99,60.0,9.31,38.6,8.73,30.9,0.0062377000000000005,-0.118116,51.1,1.502870851735007,9.322490458879487,6.433739495802647e-11,0.36985028602951026,275.6749293820898,3.3725638269431824,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL270P-35b,Yingli Energy (China),Multi-c-Si,0,270.0,241.6,1.9304999999999999,1.95,0.99,72.0,8.2,44.8,7.65,35.3,0.0035424,-0.153664,45.9,1.86517975961585,8.2123129335348,2.9952676204390466e-10,0.5388184842480177,358.8350897149905,5.682981418501159,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL275D-30b,Yingli Energy (China),Mono-c-Si,0,275.0,247.1,1.6236,1.64,0.99,60.0,9.34,38.9,8.82,31.2,0.0062578,-0.119034,51.1,1.5109083391278928,9.345060086969845,6.116283432299076e-11,0.3632651439939705,670.5214382914114,2.8997510228308943,-0.382,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL275P-35b,Yingli Energy (China),Multi-c-Si,0,275.0,246.2,1.9304999999999999,1.95,0.99,72.0,8.3,45.0,7.75,35.5,0.0035856000000000004,-0.15435000000000001,45.9,1.8739706161965994,8.311516202601256,3.0525691488265667e-10,0.528133982047143,380.6387586749229,5.738604332432838,-0.47,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL280D-30b,Yingli Energy (China),Mono-c-Si,0,280.0,251.7,1.6236,1.64,0.99,60.0,9.38,39.3,8.91,31.4,0.006284600000000001,-0.12025799999999999,51.1,1.5209741836178572,9.38000352376943,5.631124209117322e-11,0.37561311682163434,999999.8384291194,2.1617725145496047,-0.382,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL280P-35b,Yingli Energy (China),Multi-c-Si,0,280.0,250.8,1.9304999999999999,1.95,0.99,72.0,8.35,45.0,7.89,35.5,0.0036072000000000005,-0.15435000000000001,45.9,1.8635329787893773,8.35875852538927,2.72229264538166e-10,0.5235812453241457,999999.983332046,4.670468594571492,-0.47,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL285D-30b,Yingli Energy (China),Mono-c-Si,0,285.0,264.0,1.64,,,60.0,9.41,39.6,9.0,31.7,0.0029171,-0.113652,44.2,1.4762000062927734,9.410003423801548,2.1055397833421967e-11,0.36382329767272437,999990.8617389591,1.0777793022496167,-0.38,N,2025.7.3,6/23/2025,2.0,bootstrapping +Yingli Energy (China) YL285P-35b,Yingli Energy (China),Multi-c-Si,0,285.0,256.8,1.9503,1.97,0.99,72.0,8.5,45.0,8.02,35.5,0.003995,-0.1656,45.3,1.857106400132788,8.50065922117087,2.544552353725403e-10,0.5166277808116597,6661.425134486047,-3.178320558769178,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL290D-30b,Yingli Energy (China),Mono-c-Si,0,290.0,268.7,1.64,,,60.0,9.45,39.9,9.08,31.9,0.0029295,-0.114513,44.2,1.4894997396036767,9.450003621987548,2.1966407139570873e-11,0.34950321916925275,911921.5745866831,1.3891625149764402,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL290P-35b,Yingli Energy (China),Multi-c-Si,0,290.0,261.4,1.9503,1.97,0.99,72.0,8.62,45.3,8.1,35.8,0.0040514,-0.166704,45.3,1.8753539647204718,8.62530161330545,2.769536350430528e-10,0.5038944684242687,819.2925717572828,-2.611371944380698,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL295D-30b,Yingli Energy (China),Mono-c-Si,0,295.0,273.5,1.64,,,60.0,9.48,40.2,9.17,32.2,0.0029388,-0.115374,44.2,1.5061856586555111,9.480003197227244,2.429484988929198e-11,0.310592033630536,920969.0315847389,2.1904075674293026,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL295P-35b,Yingli Energy (China),Multi-c-Si,0,295.0,266.1,1.9503,1.97,0.99,72.0,8.63,45.4,8.12,36.3,0.004056100000000001,-0.167072,45.3,1.8910629065615177,8.634524903696404,3.214632988644106e-10,0.44290664158321436,844.722087712668,-1.4440330271563537,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL300D-30b {Blk},Yingli Energy (China),Mono-c-Si,0,300.0,277.3,1.58,,,60.0,9.82,39.7,9.25,32.6,0.0036334,-0.10996900000000001,45.78,1.4937014058007558,9.829587876246427,2.776063724141578e-11,0.27339803175091937,280.01704294699107,6.709188032799515,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL300D-30b {Wht},Yingli Energy (China),Mono-c-Si,0,300.0,278.2,1.64,,,60.0,9.52,40.5,9.26,32.4,0.0029511999999999997,-0.116235,44.2,1.5201861108098162,9.520002700865797,2.5608828833359647e-11,0.28363227166101784,999792.2600523792,2.5905265009443137,-0.38,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL300P-35b,Yingli Energy (China),Multi-c-Si,0,300.0,270.7,1.9503,1.97,0.99,72.0,8.77,46.3,8.17,36.7,0.0041219,-0.17038399999999998,45.3,1.9288490994740763,8.784723815766483,3.243715796132256e-10,0.49077543287389563,292.3224117195108,-1.4711788788302862,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL305D-30b {Blk},Yingli Energy (China),Mono-c-Si,0,305.0,282.0,1.58,,,60.0,9.85,40.0,9.28,32.9,0.0036445,-0.11080000000000001,45.78,1.5061246209974994,9.859330051207492,2.8410713937983523e-11,0.2679501508924678,282.88258718298755,6.882270163101749,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL305D-30b {Wht},Yingli Energy (China),Mono-c-Si,0,305.0,280.3,1.575,,,60.0,9.85,40.0,9.28,32.9,0.0038415000000000003,-0.11040000000000001,47.85,1.4953472967231336,9.85966569889142,2.345320174312346e-11,0.27048279111464746,275.6402358719275,5.59863986095939,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL305P-35b,Yingli Energy (China),Multi-c-Si,0,305.0,275.4,1.9503,1.97,0.99,72.0,8.87,46.3,8.25,37.0,0.0041689,-0.17038399999999998,45.3,1.9398476787090635,8.885800933584818,3.748041013600805e-10,0.4421009536736405,248.17749203752135,-0.3992456082144391,-0.46,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL310D-30b {Blk},Yingli Energy (China),Mono-c-Si,0,310.0,286.8,1.58,,,60.0,9.88,40.3,9.31,33.2,0.0036556,-0.11163100000000001,45.78,1.5185451090868576,9.88907562992553,2.906489191232055e-11,0.2625398498075063,285.80867387929044,7.052378913934287,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL310D-30b {Wht},Yingli Energy (China),Mono-c-Si,0,310.0,285.0,1.575,,,60.0,9.88,40.3,9.31,33.2,0.0038532000000000006,-0.11122800000000001,47.85,1.5076738082811205,9.889405015570604,2.399447931463236e-11,0.2650893000108739,278.47718196892157,5.767391298570263,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL310P-35b,Yingli Energy (China),Multi-c-Si,0,310.0,280.0,1.9503,1.97,0.99,72.0,8.99,45.6,8.53,36.3,0.0042253,-0.167808,45.3,1.893900156240617,8.990003870059983,3.1413740981735217e-10,0.43024310615180866,999998.9900845767,-1.9663752096919134,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL315D-30b {Blk},Yingli Energy (China),Mono-c-Si,0,315.0,291.5,1.58,,,60.0,9.91,40.6,9.34,33.5,0.0036667,-0.11246200000000002,45.78,1.5309629136094525,9.918824656335355,2.9723055684497154e-11,0.25716670963430005,288.795623320236,7.219588154816972,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL315D-30b {Wht},Yingli Energy (China),Mono-c-Si,0,315.0,289.8,1.575,,,60.0,9.91,40.6,9.34,33.5,0.0038649,-0.11205600000000002,47.85,1.5199976285430712,9.9191478801225,2.4539065639919068e-11,0.2597328555072554,281.3714865228341,5.93326048026495,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL315P-35b,Yingli Energy (China),Multi-c-Si,0,315.0,284.7,1.9404,1.96,0.99,72.0,9.06,45.8,8.6,36.6,0.0042582,-0.16854399999999997,45.3,1.9060925081477507,9.06000370917017,3.32510321835966e-10,0.40917951787184176,999999.8637165091,-1.5778384794740756,-0.46,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL320D-30b {Blk},Yingli Energy (China),Mono-c-Si,0,320.0,296.3,1.58,,,60.0,9.94,41.0,9.37,33.8,0.0036777999999999997,-0.11357000000000002,45.78,1.5451956003643879,9.948782343694669,2.9389947519115136e-11,0.26263307041074496,297.2524019862932,7.094841341301414,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL320D-30b {Wht},Yingli Energy (China),Mono-c-Si,0,320.0,294.5,1.575,,,60.0,9.94,41.0,9.37,33.8,0.0038766,-0.11316000000000002,47.85,1.534132493601341,9.949108400451694,2.4263224137549624e-11,0.2652120050764663,289.42593998475456,5.809545302049167,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL320P-35b,Yingli Energy (China),Multi-c-Si,0,320.0,298.3,1.94,,,72.0,9.18,46.0,8.64,37.0,0.0031212,-0.13294,42.3,1.729879560217463,9.19033542516628,2.5656221296065517e-11,0.43828529782319964,389.28820480081123,2.194184687777579,-0.381,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL325D-30b {Blk},Yingli Energy (China),Mono-c-Si,0,325.0,301.1,1.58,,,60.0,9.97,41.3,9.4,34.1,0.0036889,-0.114401,45.78,1.5576094902603368,9.978540151554718,3.004189976169327e-11,0.25729617616094486,300.37440175370466,7.25835512838143,-0.371,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL325D-30b {Wht},Yingli Energy (China),Mono-c-Si,0,325.0,299.2,1.575,,,60.0,9.97,41.3,9.4,34.1,0.0038883000000000003,-0.113988,47.85,1.5464524374533255,9.978860140794696,2.4802673249817572e-11,0.25989159213911367,292.44673026735654,5.971747226601711,-0.363,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL325D-36b,Yingli Energy (China),Mono-c-Si,0,325.0,292.8,1.9404,1.96,0.99,72.0,9.27,46.2,8.81,36.9,0.0053766,-0.139062,50.3,1.7749025921341193,9.270004177009568,4.5979815400515045e-11,0.45054255562975176,999996.9007413705,2.3956197095998935,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL325P-35b,Yingli Energy (China),Multi-c-Si,0,325.0,303.1,1.94,,,72.0,9.24,46.3,8.72,37.3,0.0031416000000000005,-0.13380699999999998,42.3,1.740353805625733,9.247610073393437,2.5584100677826172e-11,0.4302925591755594,522.4526966314659,2.1069824057809075,-0.381,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL330D-36b,Yingli Energy (China),Mono-c-Si,0,330.0,297.4,1.9404,1.96,0.99,72.0,9.29,46.6,8.86,37.2,0.0053882,-0.140266,50.3,1.7926618523074753,9.290004080436912,4.7707645919106164e-11,0.4391837288773282,999999.221017695,2.683493258099235,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL330P-35b,Yingli Energy (China),Multi-c-Si,0,330.0,307.9,1.94,,,72.0,9.29,46.6,8.84,37.4,0.0031586,-0.134674,42.3,1.7432245041838164,9.290004122282003,2.282564747914803e-11,0.4437042287724173,999993.8285360642,1.0968912780787627,-0.381,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL335D-36b,Yingli Energy (China),Mono-c-Si,0,335.0,302.1,1.9404,1.96,0.99,72.0,9.32,46.9,8.91,37.6,0.005405600000000001,-0.141169,50.3,1.809607736191201,9.320003815272566,5.172597760295205e-11,0.4093222820630137,999996.1315267849,3.3298171622484842,-0.384,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL335P-35b,Yingli Energy (China),Multi-c-Si,0,335.0,312.6,1.94,,,72.0,9.34,46.7,8.91,37.6,0.0031756,-0.134963,42.3,1.7512648201924745,9.34000388817837,2.4505112915192976e-11,0.4162714463331167,999999.5327795735,1.633734460815073,-0.381,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL340D-36b,Yingli Energy (China),Mono-c-Si,0,340.0,315.2,1.94432,,,72.0,9.35,47.3,8.97,37.9,0.0028985,-0.13622399999999998,43.9,1.7726956964121494,9.350004079375498,2.41398986311746e-11,0.41493305431616256,951077.8297937163,1.8949911998307523,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL345D-36b,Yingli Energy (China),Mono-c-Si,0,345.0,319.9,1.94432,,,72.0,9.38,47.7,9.02,38.3,0.0029078000000000003,-0.137376,43.9,1.7910905883778097,9.380003872873408,2.5477027753404253e-11,0.39472740269750073,956062.4116778099,2.312456273587652,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL350D-36b,Yingli Energy (China),Mono-c-Si,0,350.0,324.7,1.94,,,72.0,9.41,48.0,9.07,38.6,0.0029171,-0.13823999999999997,43.9,1.80535107061081,9.410003679387803,2.6713328297604142e-11,0.3754111120298455,960152.0724413134,2.677584922254127,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL355D-36b,Yingli Energy (China),Mono-c-Si,0,355.0,329.4,1.94,,,72.0,9.44,48.4,9.12,38.9,0.0029264,-0.139392,43.9,1.8217568826423052,9.440003581473357,2.733620335883368e-11,0.3655968951487239,963676.2467284567,2.842123208416295,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL360D-34d 1/2,Yingli Energy (China),Mono-c-Si,0,360.0,335.6,1.77,,,120.0,11.19,40.85,10.7,33.65,0.005595,-0.10743550000000002,45.89,1.4911582089875597,11.190004204300093,1.4171367796158049e-11,0.24358042700777785,648315.4840903856,5.12398018016881,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL360D-36b,Yingli Energy (China),Mono-c-Si,0,360.0,334.2,1.94,,,72.0,9.47,48.8,9.11,39.3,0.0029357000000000003,-0.14054399999999997,43.9,1.835051105572621,9.470003785626192,2.6732505089913792e-11,0.3841479398767268,961013.8352827817,2.6309317616111434,-0.383,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL365D-34d 1/2,Yingli Energy (China),Mono-c-Si,0,365.0,340.4,1.77,,,120.0,11.27,41.05,10.79,33.85,0.005635,-0.1079615,45.89,1.4998569458301267,11.270004183655342,1.4641841690678515e-11,0.23903444582798355,643926.2729763848,5.342589215627145,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL365D-36b,Yingli Energy (China),Mono-c-Si,0,365.0,337.9,1.882,,,72.0,9.88,47.3,9.35,39.1,0.004347200000000001,-0.130548,46.44,1.7620501062841616,9.886026945758857,2.151008610787711e-11,0.296572030981719,486.1719066371867,4.754761176426188,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL370D-34d 1/2,Yingli Energy (China),Mono-c-Si,0,370.0,345.2,1.77,,,120.0,11.35,41.25,10.87,34.05,0.005675,-0.10848750000000001,45.89,1.5080091760223833,11.350004186484302,1.4973598621966612e-11,0.23475499832206667,636456.5788089782,5.474040399800428,-0.338,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL370D-36b,Yingli Energy (China),Mono-c-Si,0,370.0,342.6,1.882,,,72.0,9.97,47.5,9.44,39.3,0.004386800000000001,-0.13110000000000002,46.44,1.7698643205936384,9.975659969998567,2.1837294670666038e-11,0.29094154086729446,512.4916226799147,4.804068202436279,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL375D-34d 1/2,Yingli Energy (China),Mono-c-Si,0,375.0,350.0,1.77,,,120.0,11.43,41.45,10.95,34.25,0.0057150000000000005,-0.10901350000000001,45.89,1.5163366393732403,11.430002497748692,1.5358063019827053e-11,0.21851970155732509,999998.3648897377,5.6313701298018355,-0.338,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy (China) YL375D-36b,Yingli Energy (China),Mono-c-Si,0,375.0,347.4,1.882,,,72.0,10.06,47.6,9.53,39.5,0.0044264000000000005,-0.13137600000000002,46.44,1.775860564923571,10.065232261389237,2.2810282596492843e-11,0.2748117753260969,528.3769797750982,5.096998985269613,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL380D-36b,Yingli Energy (China),Mono-c-Si,0,380.0,352.2,1.882,,,72.0,10.15,47.8,9.62,39.7,0.004466,-0.13192800000000002,46.44,1.783679464390773,10.154894231167924,2.314970539649188e-11,0.26949032693698666,558.8879584307876,5.145104768289036,-0.355,N,2025.7.3,6/23/2025,4.0,bootstrapping +Yingli Energy (China) YL385D-36b,Yingli Energy (China),Mono-c-Si,0,385.0,356.9,1.882,,,72.0,10.24,47.9,9.71,39.9,0.0045056,-0.13220400000000002,46.44,1.7896755182433108,10.244503446269045,2.4167315426715727e-11,0.2538647838003655,577.2413561531052,5.435421058051193,-0.355,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL405D-36b 1500V 1/2,Yingli Energy (China),Mono-c-Si,0,405.0,379.6,1.97,,,72.0,10.32,49.44,9.71,41.75,0.0042312,-0.1300272,44.73,1.8104591956093774,10.328918932667769,1.397952469443595e-11,0.20499664519487404,237.19938955233548,5.897032211644484,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL410D-36b 1500V 1/2,Yingli Energy (China),Mono-c-Si,0,410.0,384.4,1.97,,,72.0,10.37,49.59,9.77,41.98,0.004251700000000001,-0.13042170000000003,44.73,1.8170184429984344,10.377849398343104,1.4293268996856562e-11,0.1927523771076831,254.6490916289093,6.041386509051409,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL445D-40d 1500V 1/2,Yingli Energy (China),Mono-c-Si,0,445.0,417.5,2.12,,,72.0,11.4,49.7,10.82,41.15,0.004104,-0.12922000000000003,44.68,1.7798626855037476,11.406065908287415,8.442492981954469e-12,0.2776242422605545,521.7547370345035,2.0160966756548127,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL445DF72 1/2,Yingli Energy (China),Mono-c-Si,1,445.0,418.4,2.12,,,144.0,11.36,49.55,10.74,41.44,0.004543999999999999,-0.129821,44.03,1.7775985440317863,11.360008710499148,8.903289089712217e-12,0.23504017866515892,306534.2079176234,1.617005242188723,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL450D-40d 1500V 1/2,Yingli Energy (China),Mono-c-Si,0,450.0,422.3,2.12,,,72.0,11.42,49.8,10.89,41.35,0.0041112,-0.12948,44.68,1.7820687948188731,11.421952194905097,8.320301016882279e-12,0.2655471935309965,1553.4048370825672,1.860562219825643,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL450DF72 1/2,Yingli Energy (China),Mono-c-Si,1,450.0,423.3,2.12,,,144.0,11.42,49.8,10.8,41.67,0.004568,-0.130476,44.03,1.804294906784494,11.428099864655394,1.1619960462348528e-11,0.2294400349394402,323.48753007430173,3.8490694297460757,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy (China) YL455D-40d 1500V 1/2,Yingli Energy (China),Mono-c-Si,0,455.0,427.1,2.12,,,72.0,11.44,49.9,10.96,41.55,0.0041183999999999995,-0.12974,44.68,1.7886835919941917,11.440560120576245,8.755914841233803e-12,0.2528116311153833,5163.4690192606595,2.26335032503771,-0.331,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL400D-37e 1/2,Yingli Energy Development Co Ltd,Mono-c-Si,0,400.0,374.1,1.9,,,54.0,13.78,37.1,13.06,30.7,0.004134,-0.099799,44.3,1.3586518994798358,13.787726007839805,1.8902556252056463e-11,0.16794792729517805,299.5495877756751,3.733095783099893,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL405D-37e 1/2,Yingli Energy Development Co Ltd,Mono-c-Si,0,405.0,378.9,1.9,,,54.0,13.86,37.2,13.15,30.8,0.004158,-0.10006800000000002,44.3,1.3620011604130835,13.866601699442226,1.89162781845209e-11,0.16595713496449022,348.4202726631752,3.685971097457759,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL410D-37e 1/2,Yingli Energy Development Co Ltd,Mono-c-Si,0,410.0,383.7,1.9,,,54.0,13.94,37.3,13.25,31.0,0.004182,-0.10033700000000001,44.3,1.3670722761573366,13.944703651605506,1.9603520776348256e-11,0.15535628031910412,460.42229215504386,3.9307952496282197,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL415D-37e 1/2,Yingli Energy Development Co Ltd,Mono-c-Si,0,415.0,388.5,1.9,,,54.0,14.02,37.4,13.35,31.1,0.004206,-0.100606,44.3,1.369945854273895,14.022938545691176,1.944749737112688e-11,0.15351062744001318,732.4095928823343,3.8075713801548354,-0.354,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL540D-49e1500V ,Yingli Energy Development Co Ltd,Mono-c-Si,0,540.0,502.5,2.58,,,144.0,13.83,49.52,12.95,41.7,0.0038724000000000002,-0.1302376,45.5,1.8415084565031485,13.845361727540944,2.8291810137238593e-11,0.1583962605983002,142.6024701687059,9.685266504921511,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy Development Co Ltd YL540DF72 e/2,Yingli Energy Development Co Ltd,Mono-c-Si,1,540.0,500.4,2.52,,,144.0,13.9,49.5,12.99,41.6,0.003614,-0.13563,45.9,1.8769782495594898,13.91632101823831,4.7712150986409206e-11,0.15839380703482112,134.8980744374082,9.776971792377122,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL545D-49e1500V ,Yingli Energy Development Co Ltd,Mono-c-Si,0,545.0,507.3,2.58,,,144.0,13.9,49.67,13.03,41.85,0.0038920000000000005,-0.1306321,45.5,1.8465953351895288,13.91446326230713,2.8267778371979615e-11,0.15613651901500517,150.0558848819406,9.628088394722674,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy Development Co Ltd YL545DF72 e/2,Yingli Energy Development Co Ltd,Mono-c-Si,1,545.0,505.1,2.52,,,144.0,13.97,49.6,13.06,41.8,0.0036322000000000004,-0.13590400000000002,45.9,1.883164114679468,13.985208301703329,4.9594977535072814e-11,0.1477350239115845,135.70603337919425,10.074418436795854,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL550D-49e1500V ,Yingli Energy Development Co Ltd,Mono-c-Si,0,550.0,512.1,2.58,,,144.0,13.97,49.82,13.1,42.0,0.0039116,-0.13102660000000002,45.5,1.8523934410463925,13.984128243620637,2.851141300616889e-11,0.15379856983479684,152.07594727693788,9.658247913606857,-0.357,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL550DF72 e/2,Yingli Energy Development Co Ltd,Mono-c-Si,1,550.0,509.9,2.52,,,144.0,14.04,49.8,13.13,41.9,0.0036504,-0.13645200000000002,45.9,1.8888066891883486,14.055592620941308,4.853314399764797e-11,0.15366031173010472,138.35972799509435,9.836440103682879,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Yingli Energy Development Co Ltd YL555D-49e1500V ,Yingli Energy Development Co Ltd,Mono-c-Si,0,555.0,516.8,2.58,,,144.0,14.04,49.97,13.17,42.15,0.0039312,-0.1314211,45.5,1.8581923837917973,14.053798642664747,2.8756091308226494e-11,0.15148536447120092,154.13505359554244,9.688325385275725,-0.357,N,2025.7.3,6/23/2025,2.0,first_pass +Yingli Energy Development Co Ltd YL555DF72 e/2,Yingli Energy Development Co Ltd,Mono-c-Si,1,555.0,514.7,2.52,,,144.0,14.11,49.9,13.2,42.1,0.0036685999999999997,-0.13672600000000001,45.9,1.8949913925524768,14.124511217205646,5.043316119627237e-11,0.1431414765587601,139.1837925477531,10.131823313001732,-0.374,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B435-06-72-1,Yotta Energy Inc,Mono-c-Si,1,435.0,402.9,2.17,,,72.0,11.16,49.8,10.51,41.4,0.00837,-0.1485036,45.3,1.9747284262325364,11.167630444598117,1.229655146206924e-10,0.22772913330478042,333.0680411060258,10.079801025529674,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B440-06-72-1,Yotta Energy Inc,Mono-c-Si,1,440.0,407.7,2.17,,,72.0,11.22,50.0,10.58,41.6,0.008415,-0.1491,45.3,1.9652320942547377,11.220008566470966,1.001247862048935e-10,0.22709290032958845,297445.8731176091,8.175544310769393,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B445-06-72-1,Yotta Energy Inc,Mono-c-Si,1,445.0,412.5,2.17,,,72.0,11.29,50.2,10.65,41.8,0.0084675,-0.1496964,45.3,1.9906444062659947,11.29642621601982,1.2470717788071537e-10,0.2198006556945993,386.16030250029667,10.096251909924328,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B450-06-72-1,Yotta Energy Inc,Mono-c-Si,1,450.0,417.2,2.17,,,72.0,11.36,50.4,10.72,42.0,0.00852,-0.1502928,45.3,1.982980701323951,11.360008153046595,1.0404484709069292e-10,0.2187271396950907,304771.9135689536,8.403584994100779,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B455-06-72-1,Yotta Energy Inc,Mono-c-Si,1,455.0,422.0,2.17,,,72.0,11.43,50.6,10.79,42.2,0.0085725,-0.1508892,45.3,1.9918492573918811,11.43000651354162,1.060300556211842e-10,0.2146268514077865,376643.3022534545,8.515624568806997,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B460-06-72-1,Yotta Energy Inc,Mono-c-Si,1,460.0,426.8,2.17,,,72.0,11.5,50.8,10.86,42.4,0.008625,-0.15148560000000003,45.3,2.0158830904530123,11.505618850646735,1.2948265010909266e-10,0.20780073325739934,425.30202486314465,10.263740584198366,-0.3766,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B530-10-72-1,Yotta Energy Inc,Mono-c-Si,1,530.0,489.2,2.591,,,72.0,13.72,49.32,12.83,41.32,0.00801248,-0.1447542,45.4,1.976098554178514,13.733145878556856,1.9437463509665312e-10,0.15280405839453212,159.47749169418748,14.394409178935291,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B535-10-72-1,Yotta Energy Inc,Mono-c-Si,1,535.0,493.9,2.591,,,72.0,13.79,49.46,12.9,41.48,0.008053359999999999,-0.1451651,45.4,1.9824507304374503,13.802685946358062,1.9726422351956198e-10,0.14866979784993564,161.60848482770635,14.482677686173627,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Yotta Energy Inc YSM-B540-10-72-1,Yotta Energy Inc,Mono-c-Si,1,540.0,498.7,2.591,,,72.0,13.86,49.6,12.97,41.64,0.00809424,-0.145576,45.4,1.9888029938778018,13.87223531479409,2.001791940217873e-10,0.1445806129008945,163.77897794734116,14.570448961699775,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +Yotta Energy Inc YSM-B545-10-72-1,Yotta Energy Inc,Mono-c-Si,1,545.0,503.4,2.591,,,72.0,13.93,49.76,13.04,41.8,0.008135120000000001,-0.1460456,45.4,1.9955217285242652,13.941902369896981,2.020245533138922e-10,0.14208992431978462,166.29568067230187,14.60754433055536,-0.3945,N,2025.7.3,6/23/2025,2.0,first_pass +Yotta Energy Inc YSM-B550-10-72-1,Yotta Energy Inc,Mono-c-Si,1,550.0,508.2,2.591,,,72.0,14.0,49.92,13.11,41.96,0.008176000000000001,-0.1465152,45.4,2.0022412764382227,14.01157557271183,2.0387789236238984e-10,0.1396257885275673,168.86949330184873,14.644485208268554,-0.3945,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-BF400W-BLK ,Your Energy Solutions,Mono-c-Si,1,400.0,376.5,1.93,,,54.0,13.74,37.1,13.08,30.6,0.0064578,-0.094605,43.6,1.3400739526714545,13.743349133841447,1.297295921947186e-11,0.17963558295680895,736.9645541728028,5.936489830832071,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-BF405W-BLK,Your Energy Solutions,Mono-c-Si,1,405.0,381.3,1.93,,,54.0,13.79,37.4,13.13,30.9,0.0064813,-0.09537,43.6,1.3519264352757847,13.793225637946039,1.3294603270336225e-11,0.17584536069689727,751.7606174448372,6.116590519819704,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-BF410W-BLK,Your Energy Solutions,Mono-c-Si,1,410.0,386.1,1.93,,,54.0,13.83,37.7,13.18,31.2,0.0065001,-0.09613500000000001,43.6,1.363323493449661,13.832315393058462,1.3495609756915635e-11,0.17222719326122723,1028.7247511503103,6.217975295570683,-0.332,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-425W,Your Energy Solutions,Mono-c-Si,1,425.0,402.8,1.95,,,54.0,14.05,38.29,13.23,32.23,0.006884500000000001,-0.08749265,43.5,1.351605912386067,14.064240431764517,6.852190731132193e-12,0.13389117247680118,132.10073856795245,12.134000521099983,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-430W,Your Energy Solutions,Mono-c-Si,1,430.0,407.6,1.95,,,54.0,14.13,38.42,13.28,32.49,0.0069237000000000005,-0.08778970000000001,43.5,1.3603758681840565,14.144555896062508,7.498259811251692e-12,0.1205472986980351,117.02018877643302,12.925000794245635,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-435W,Your Energy Solutions,Mono-c-Si,1,435.0,412.5,1.95,,,54.0,14.22,38.5,13.32,32.76,0.006967800000000001,-0.08797250000000001,43.5,1.3693621122688096,14.234850757599402,8.529054105676572e-12,0.10245869293563115,98.10695553671871,14.083606182025223,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-440W,Your Energy Solutions,Mono-c-Si,1,440.0,417.3,1.95,,,54.0,14.3,38.63,13.36,32.98,0.007007000000000001,-0.08826955000000002,43.5,1.3778653882298875,14.315134510489514,9.252563259936855e-12,0.09263157919171527,87.52391330207205,14.808541109921979,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-445W,Your Energy Solutions,Mono-c-Si,1,445.0,422.2,1.95,,,54.0,14.38,38.76,13.4,33.23,0.007046200000000001,-0.08856660000000001,43.5,1.386993234336706,14.394614508923565,1.0153959175930583e-11,0.08030910946472843,79.0204447637252,15.647224973314811,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-450W,Your Energy Solutions,Mono-c-Si,1,450.0,427.0,1.95,,,54.0,14.47,38.84,13.44,33.51,0.007090300000000002,-0.0887494,43.5,1.3962864577755418,14.482682706759695,1.1570377582623032e-11,0.06163230489056923,70.31775388241036,16.8480259460567,-0.3029,N,2025.7.3,6/23/2025,4.0,first_pass +Your Energy Solutions YES-NBF108-455W,Your Energy Solutions,Mono-c-Si,1,455.0,431.9,1.95,,,54.0,14.54,39.02,13.48,33.76,0.0071246,-0.08916070000000001,43.5,1.4059324554387713,14.55167858653924,1.2350330160585163e-11,0.05333239088752321,66.39955627474598,17.436618315384322,-0.3029,N,2025.7.3,6/23/2025,2.0,first_pass +Zebra Energy ZBR-185M5,Zebra Energy,Mono-c-Si,0,185.0,167.3,1.279029,1.581,0.809,72.0,5.27,46.1,4.79,38.6,0.0038523699999999995,-0.17370480000000002,45.8,2.014620153043647,5.279606552075038,5.770452893279678e-10,0.30155551751433324,165.4285199848462,4.832273095391433,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-190M5,Zebra Energy,Mono-c-Si,0,190.0,171.9,1.279029,1.581,0.809,72.0,5.42,46.2,4.92,38.6,0.00396202,-0.17408160000000003,45.8,2.017869473141242,5.4308167492431805,5.851941276473322e-10,0.31319711130147565,156.93517768003397,4.7153879243289145,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-195M5,Zebra Energy,Mono-c-Si,0,195.0,176.6,1.279029,1.581,0.809,72.0,5.56,46.1,5.05,38.6,0.0040643599999999995,-0.17370480000000002,45.8,2.0155008901028397,5.570280134630801,6.143892386904614e-10,0.28537583540183875,154.34523139615362,4.91246591594592,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-200M5,Zebra Energy,Mono-c-Si,0,200.0,181.2,1.279029,1.581,0.809,72.0,5.82,45.9,5.43,36.8,0.00425442,-0.17295120000000003,45.8,1.9238327846155758,5.828245781110433,2.490310403718567e-10,0.6418382825515013,453.01948087201356,-2.95739079890728,-0.4341,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-200P,Zebra Energy,Multi-c-Si,0,200.0,175.9,1.6335,1.65,0.99,60.0,7.85,34.92,6.87,29.1,0.004195821185617105,-0.12218269230769233,47.3,1.6132932791277983,7.874545481576548,2.8347651435645276e-09,0.1460183504459261,46.698785764056,24.899482112972386,-0.49253075571177507,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-210P,Zebra Energy,Multi-c-Si,0,210.0,184.9,1.6335,1.65,0.99,60.0,8.12,35.4,7.17,29.3,0.004340136054421769,-0.1238621794871795,47.3,1.6187172554048956,8.148515038777598,2.3715899241714893e-09,0.1803736357588491,51.36356688928597,22.710096736960377,-0.49253075571177507,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-220P,Zebra Energy,Multi-c-Si,0,220.0,194.0,1.6335,1.65,0.99,60.0,8.4,35.87,7.48,29.4,0.004489795918367348,-0.12550667735042734,47.3,1.6212243937429744,8.433209148914282,1.9210277087768417e-09,0.22597144705985675,57.15775506534448,20.244930285257805,-0.49253075571177507,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-230P,Zebra Energy,Multi-c-Si,0,230.0,203.1,1.6335,1.65,0.99,60.0,8.78,37.48,7.81,30.73,0.00469290573372206,-0.13113995726495725,47.3,1.6955026153623163,8.81501587711931,2.0451316610585247e-09,0.22399548327916222,56.16539571476045,20.429248767204257,-0.49253075571177507,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-235P,Zebra Energy,Multi-c-Si,0,235.0,212.2,1.6335,1.65,0.99,72.0,8.8,36.2,7.91,29.7,0.0072688000000000015,-0.136836,45.7,1.5970958428410236,8.83087263314266,1.1840210900314251e-09,0.2236527754282273,63.750461388645,6.171165301199772,-0.44096,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-240MA,Zebra Energy,Mono-c-Si,0,240.0,216.7,1.6335,1.65,0.99,72.0,8.55,37.57,7.92,30.3,0.006916950000000001,-0.15606578000000002,45.8,1.6201485126020196,8.566197482027636,7.087187716858994e-10,0.3218560626560654,169.89491753657734,-7.273016111737415,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-240PA,Zebra Energy,Multi-c-Si,0,240.0,216.8,1.6335,1.65,0.99,72.0,8.88,36.2,8.08,29.7,0.007334880000000001,-0.136836,45.7,1.585260313781359,8.904297764515908,1.023861701249667e-09,0.2243618045131896,81.99655710998397,4.8082075571825165,-0.44096,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-245MA,Zebra Energy,Mono-c-Si,0,245.0,221.3,1.6335,1.65,0.99,72.0,8.68,37.82,8.03,30.5,0.00702212,-0.15710428,45.8,1.632098964162359,8.697488088888543,7.304167986846849e-10,0.31925198375945896,158.45686469598044,-7.156144353331228,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-250MA,Zebra Energy,Mono-c-Si,0,250.0,226.0,1.6335,1.65,0.99,72.0,8.79,38.07,8.14,30.7,0.0071111099999999995,-0.15814278,45.8,1.6418703523203544,8.806900843403882,7.300219147788808e-10,0.3176816307629478,165.22382970857336,-7.257774890041855,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-250P,Zebra Energy,Multi-c-Si,0,250.0,224.6,1.93743,1.957,0.99,72.0,8.57,40.9,7.23,34.6,0.00768729,-0.16253659999999998,46.5,1.934071979648395,8.5840647648622,4.8538512794315334e-09,0.05745094034090405,35.00624523798913,13.69772421662836,-0.4352,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-255M,Zebra Energy,Mono-c-Si,0,255.0,230.6,1.6335,1.65,0.99,72.0,8.94,38.19,8.28,30.8,0.00723246,-0.15864125999999998,45.8,1.647029372074083,8.957061881230889,7.424175655788254e-10,0.3128835625315982,163.9432108350511,-7.258700565478079,-0.4416,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-260P,Zebra Energy,Multi-c-Si,0,260.0,233.8,1.93743,1.957,0.99,72.0,8.59,42.26,7.45,34.9,0.00770523,-0.16794124,46.5,1.9271126771216156,8.630090351711418,2.3099658641546724e-09,0.21549591002663518,46.17345441556361,6.832307561345997,-0.4352,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-270P,Zebra Energy,Multi-c-Si,0,270.0,243.0,1.93743,1.957,0.99,72.0,8.52,44.5,7.91,35.38,0.00764244,-0.176843,46.5,1.897698195620035,8.536184352428998,5.468177428371069e-10,0.4600848274160385,242.2045404238007,-5.143614092079763,-0.4352,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-280P,Zebra Energy,Multi-c-Si,0,280.0,252.2,1.93743,1.957,0.99,72.0,8.9,45.29,7.95,36.48,0.0079833,-0.17998246,46.5,1.992388100013688,8.946594980719745,1.11584811098208e-09,0.374444009406463,71.5216956312347,0.27598561326137044,-0.4352,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-285P,Zebra Energy,Multi-c-Si,0,285.0,257.7,1.93743,1.957,0.99,72.0,8.75,43.8,7.96,35.8,0.007218750000000001,-0.164031,46.0,1.8953140652513663,8.776433498735209,7.666264489131116e-10,0.3005501019105732,99.48791294110305,3.4589705257301175,-0.4315,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-290M,Zebra Energy,Mono-c-Si,0,290.0,261.9,1.93743,1.957,0.99,72.0,8.78,44.2,8.06,36.0,0.006163559999999999,-0.16698760000000004,46.3,1.880424918194035,8.802548416348243,5.23517095231058e-10,0.3275352072105299,127.53708798624689,-0.4901416351592147,-0.4328,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-290P,Zebra Energy,Multi-c-Si,0,290.0,262.3,1.93743,1.957,0.99,72.0,8.78,44.2,8.06,36.0,0.007243499999999999,-0.165529,46.0,1.898320310439177,8.801921270937855,6.537009881616908e-10,0.3229231602604118,129.33856102896033,2.0709905450263824,-0.4315,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-295M,Zebra Energy,Mono-c-Si,0,295.0,266.5,1.93743,1.957,0.99,72.0,8.88,44.3,8.17,36.1,0.0062337600000000005,-0.16736540000000003,46.3,1.8828489394761267,8.901078979698644,5.188782397927867e-10,0.322257781040255,135.7584374639203,-0.6593954079207757,-0.4328,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-295P,Zebra Energy,Multi-c-Si,0,295.0,267.0,1.93743,1.957,0.99,72.0,8.88,44.3,8.17,36.1,0.007326000000000001,-0.1659035,46.0,1.9007652498604035,8.90046962793806,6.480327153167137e-10,0.31770296143066346,137.8238339620093,1.8987659839053492,-0.4315,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-300M,Zebra Energy,Mono-c-Si,0,300.0,271.1,1.93743,1.957,0.99,72.0,8.9,44.5,8.29,36.2,0.0062478,-0.16812100000000002,46.3,1.8761846064189764,8.912608672000065,4.3647340040388054e-10,0.33389628754345374,235.68519806367462,-2.096126303688972,-0.4328,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-300P,Zebra Energy,Multi-c-Si,0,300.0,271.6,1.93743,1.957,0.99,72.0,8.9,44.5,8.29,36.2,0.007342500000000001,-0.1666525,46.0,1.893995689761883,8.912111083290862,5.45820742382666e-10,0.3294514786808877,242.10208474562063,0.43296617347110916,-0.4315,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-305M,Zebra Energy,Mono-c-Si,0,305.0,275.8,1.93743,1.957,0.99,72.0,8.97,44.8,8.38,36.4,0.00629694,-0.1692544,46.3,1.884351370244812,8.980609511189428,4.173102318605037e-10,0.34012338051815977,287.56339934954997,-2.522514373964667,-0.4328,N,2025.7.3,6/23/2025,4.0,first_pass +Zebra Energy ZBR-310M,Zebra Energy,Mono-c-Si,0,310.0,280.4,1.93743,1.957,0.99,72.0,9.06,45.0,8.47,36.6,0.0063601199999999995,-0.17001000000000002,46.3,1.893197009676662,9.070081003702619,4.2410155017070143e-10,0.3330921355695496,299.35662513460363,-2.4756081464280566,-0.4328,N,2025.7.3,6/23/2025,4.0,first_pass +Zetsol Energy Inc ZS-BG-T66700-G12,Zetsol Energy Inc,Mono-c-Si,0,700.0,666.2,3.08,,,22.0,18.1,48.6,17.44,40.1,0.007602000000000001,-0.11421,43.1,1.6583389195391955,18.100281718098707,3.3881825583411003e-12,0.18910792938696847,12149.92486547816,0.7494332954931694,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Zetsol Energy Inc ZS-BG-T66705-G12,Zetsol Energy Inc,Mono-c-Si,0,705.0,671.1,3.08,,,22.0,18.14,48.8,17.48,40.3,0.007618800000000001,-0.11467999999999999,43.1,1.665790796007966,18.140283766092125,3.433348353808374e-12,0.18718984361529073,11966.278048175382,0.8417296499744439,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Zetsol Energy Inc ZS-BG-T66710-G12,Zetsol Energy Inc,Mono-c-Si,0,710.0,675.9,3.08,,,22.0,18.18,49.0,17.52,40.5,0.0076356,-0.11514999999999999,43.1,1.6732429177224937,18.180285785009517,3.4787720349102765e-12,0.1852807865446611,11786.499529400582,0.9333085925375249,-0.291,N,2025.7.3,6/23/2025,2.0,first_pass +Zetsol Energy Inc ZS-BG-T66715-G12,Zetsol Energy Inc,Mono-c-Si,0,715.0,680.8,3.08,,,22.0,18.22,49.2,17.56,40.7,0.0076524,-0.11562,43.1,1.6808201880364444,18.220003557703986,3.5328830541991726e-12,0.16645005709509922,852441.6978422353,1.0433465208637744,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Zetsol Energy Inc ZS-BG-T66720-G12,Zetsol Energy Inc,Mono-c-Si,0,720.0,685.7,3.08,,,22.0,18.26,49.4,17.6,40.9,0.007669200000000001,-0.11609,43.1,1.6882707184781267,18.26000347495252,3.578776517898373e-12,0.1644568187721056,864183.487375023,1.133157908322184,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Zetsol Energy Inc ZS-BG-T66725-G12,Zetsol Energy Inc,Mono-c-Si,0,725.0,690.6,3.08,,,22.0,18.3,49.6,17.64,41.1,0.007686000000000002,-0.11656000000000001,43.1,1.695721520685675,18.300003481374315,3.624924189874627e-12,0.16247101012944504,854040.3574110665,1.2222843166213078,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Zetsol Energy Inc ZS-BG-T66730-G12,Zetsol Energy Inc,Mono-c-Si,0,730.0,695.4,3.08,,,22.0,18.34,49.7,17.68,41.3,0.007702800000000001,-0.11679500000000001,43.1,1.701101679942326,18.340003328401924,3.7574556980109125e-12,0.1552261588924274,855323.8565942126,1.505637305147768,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Zetsol Energy Inc ZS-BG-T66735-G12,Zetsol Energy Inc,Mono-c-Si,0,735.0,700.3,3.08,,,22.0,18.38,49.9,17.72,41.5,0.0077196,-0.117265,43.1,1.7085525212205224,18.38000329055536,3.804834220834616e-12,0.15326772450181528,856109.0902663688,1.5927424798767993,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Zetsol Energy Inc ZS-BG-T66740-G12,Zetsol Energy Inc,Mono-c-Si,0,740.0,705.2,3.08,,,22.0,18.42,50.1,17.76,41.7,0.007736400000000002,-0.11773499999999999,43.1,1.7160035393172297,18.420003252774173,3.852457164441664e-12,0.15131670811795805,856889.215965454,1.6791779269870923,-0.291,N,2025.7.3,6/23/2025,2.0,bootstrapping +Zhejiang Kingdom Solar Energy Technic KD-M160,Zhejiang Kingdom Solar Energy Technic,Mono-c-Si,0,160.0,141.7,1.2766400000000002,1.58,0.808,72.0,5.02,43.6,4.49,35.62,0.00251,-0.14824,48.3,1.8720056010091162,5.042203816454792,3.592702162378281e-10,0.5343861178806649,120.81789883940186,12.659807298187399,-0.45,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP390-108M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,390.0,366.0,1.9,,,54.0,13.62,36.53,12.83,30.41,0.0072185999999999995,-0.10264930000000001,43.9,1.3615041021800376,13.632360862276308,2.9853114433019454e-11,0.14809427660908514,163.17988308447136,2.838515908551861,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG390-108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,390.0,366.5,1.9,,,54.0,13.62,36.53,12.83,30.41,0.00681,-0.1000922,43.2,1.3628849544408375,13.632302827582816,3.067723425690962e-11,0.14785635162153443,163.6862349329422,5.758300584902457,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP395-108M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,395.0,370.8,1.9,,,54.0,13.69,36.73,12.9,30.62,0.0072556999999999995,-0.10321129999999999,43.9,1.3697542932974534,13.701903201568031,3.048519809683255e-11,0.14428026995437923,165.93828985602605,2.969826250391623,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG395-108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,395.0,371.4,1.9,,,54.0,13.69,36.73,12.9,30.62,0.006845,-0.1006402,43.2,1.3655319862694746,13.702076953536027,2.8055482004296613e-11,0.14500509170407883,164.37255592881152,4.9517902908591935,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP400-108M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,400.0,375.6,1.9,,,54.0,13.76,36.93,12.98,30.83,0.0072927999999999995,-0.10377330000000001,43.9,1.3774788589665061,13.770782256964242,3.083525413519358e-11,0.14056420680057558,179.38391831900688,3.0187433069186946,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG400-108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,400.0,376.2,1.9,,,54.0,13.76,36.93,12.98,30.83,0.006880000000000001,-0.1011882,43.2,1.3723387408243495,13.770984478463234,2.7884419813025607e-11,0.141441933117073,177.18101243198157,4.852556141874503,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP405-108M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,405.0,380.4,1.9,,,54.0,13.83,37.13,13.05,31.04,0.0073299,-0.10433530000000002,43.9,1.3857245791376975,13.840365765670509,3.147396548219318e-11,0.1368371279092207,182.56803118997638,3.146954422252544,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP410-108M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,410.0,385.2,1.9,,,54.0,13.9,37.33,13.12,31.25,0.007367,-0.1048973,43.9,1.3939686152499713,13.909959530153786,3.211821850095549e-11,0.13315092588099384,185.83184725727708,3.273526402245274,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG410-108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,410.0,385.8,1.9,,,54.0,13.9,37.33,13.12,31.25,0.006950000000000001,-0.10228419999999999,43.2,1.395361184911705,13.909907898314943,3.2989715541167895e-11,0.1329154419550419,186.46988511363048,6.201297316367487,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG410-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,410.0,389.1,1.9,,,54.0,13.85,37.94,13.12,31.25,0.0059555,-0.09522939999999999,43.4,1.3077381819645353,13.862033915465574,3.4421703181430914e-12,0.19693095533666402,226.65056480720872,-3.445212372634811,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG415-108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,415.0,390.6,1.9,,,54.0,13.97,37.53,13.19,31.47,0.006985000000000002,-0.10283220000000001,43.2,1.4038347795888868,13.97946642369411,3.3798811108966015e-11,0.12839836973406935,189.4828817838831,6.365971231054028,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG415-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,415.0,394.0,1.9,,,54.0,13.96,38.04,13.23,31.37,0.0060028,-0.0954804,43.4,1.3116804902982941,13.971496396239205,3.5091302985155054e-12,0.19264685824683073,233.92984122129704,-3.3559719337979774,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP420-108M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,420.0,394.9,1.9,,,54.0,14.04,37.73,13.26,31.69,0.007441199999999999,-0.1060213,43.9,1.4109114428999092,14.04908428783999,3.371374386257259e-11,0.12416433927623148,191.899166834167,3.5947550460893245,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG420-108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,420.0,395.5,1.9,,,54.0,14.04,37.73,13.26,31.69,0.00702,-0.1033802,43.2,1.4123061239533872,14.049035762135656,3.4617492132294555e-11,0.12393046151905605,192.56634579465617,6.528637949247038,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG420-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,420.0,398.9,1.9,,,54.0,14.07,38.13,13.34,31.49,0.0060501,-0.09570630000000001,43.4,1.315443876950508,14.080954725599025,3.5899328383080988e-12,0.18767858390810258,241.05009819833154,-3.2380750181261306,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG425-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,425.0,403.7,1.9,,,54.0,14.16,38.24,13.44,31.64,0.006088799999999999,-0.09598240000000001,43.4,1.3197727286197085,14.169596701265174,3.6595272631392e-12,0.1820067432836156,268.5522264393162,-3.1394766285644975,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG430-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,430.0,408.6,1.9,,,54.0,14.25,38.34,13.53,31.79,0.0061275,-0.09623340000000001,43.4,1.32435939238166,14.259141933985697,3.776152889525853e-12,0.17566909644416495,273.8244045580284,-2.9396513788973766,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP435-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,435.0,408.3,2.11,,,60.0,13.55,40.8,12.77,34.07,0.0071815,-0.114648,43.9,1.5227432040755282,13.561376070861138,3.082286076108654e-11,0.1567929158456671,186.75551981817756,3.14776426922885,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG435-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,435.0,408.9,2.11,,,60.0,13.55,40.8,12.77,34.07,0.006775000000000001,-0.111792,43.2,1.5242712052428897,13.561321146185739,3.1663458911587204e-11,0.15652782042390048,187.34428034149943,6.073300583750723,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG435-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,435.0,413.4,1.9,,,54.0,14.34,38.43,13.62,31.94,0.006166199999999999,-0.09645930000000001,43.4,1.328763790423963,14.348684410646774,3.9094550951148e-12,0.16867830468587583,278.52742834884407,-2.7123947123356777,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP440-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,440.0,413.1,2.11,,,60.0,13.6,41.1,12.83,34.32,0.007208,-0.11549100000000002,43.9,1.5331669441822005,13.61055649707521,3.0557660919427105e-11,0.157494044015343,202.90054572233694,3.0407040434265706,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG440-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,440.0,413.7,2.11,,,60.0,13.6,41.1,12.83,34.32,0.0068000000000000005,-0.11261400000000002,43.2,1.5347104549963326,13.61050315585457,3.139420370343114e-11,0.15722758424617808,203.5859692926563,5.964084362493497,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG440-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,440.0,418.3,1.9,,,18.0,14.43,38.53,13.72,32.09,0.0062049,-0.09671030000000001,43.4,1.3329109431600021,14.437467196373557,3.997452170023707e-12,0.16253173736804388,314.084812813489,-2.587620805311604,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP445-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,445.0,417.9,2.11,,,60.0,13.65,41.3,12.88,34.56,0.0072345000000000005,-0.116053,43.9,1.5421461889645125,13.660094770623065,3.14922053269134e-11,0.15117767026346363,204.42021857165932,3.2618099295619354,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG445-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,445.0,418.5,2.11,,,60.0,13.65,41.3,12.88,34.56,0.006825000000000001,-0.113162,43.2,1.5436864300142035,13.660043379412022,3.2346554403807446e-11,0.1509124157275356,205.10571280197874,6.189236170449108,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG445-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,445.0,423.2,1.9,,,18.0,14.53,38.64,13.8,32.25,0.006247899999999999,-0.0969864,43.4,1.3387260654107285,14.538557616776462,4.1975166396094606e-12,0.15620957903999041,265.22865367227735,-2.2445166451582756,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG445-N96R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,445.0,421.1,1.94,,,16.0,15.86,35.54,14.99,29.69,0.0066612,-0.08671759999999999,44.9,1.2314244315953309,15.874873547269612,4.5657302436678184e-12,0.12990181340269955,138.51724312494395,0.5858086178960592,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP450-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,450.0,422.7,2.11,,,60.0,13.7,41.5,12.93,34.81,0.007260999999999999,-0.11661500000000002,43.9,1.5513498489378512,13.709594818213615,3.2569970642425854e-11,0.14402361288665352,205.64470007471715,3.513142318812384,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG450-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,450.0,423.3,2.11,,,60.0,13.7,41.5,12.93,34.81,0.006849999999999999,-0.11371000000000002,43.2,1.5528879937640312,13.709545484623243,3.344604279098846e-11,0.14375930575571488,206.3281838710934,6.445578437290903,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG450-N108M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,450.0,428.0,1.9,,,18.0,14.63,38.75,13.89,32.41,0.0062909,-0.0972625,43.4,1.3441033456962659,14.638817243835781,4.368308766405536e-12,0.14998728782772103,248.86620621274636,-1.975591918515045,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG450-N96R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,450.0,426.0,1.94,,,16.0,15.9,35.8,15.04,29.93,0.006678000000000001,-0.087352,44.9,1.2404256858641625,15.913870946614987,4.580465914314427e-12,0.12882229643422738,147.66652724176893,0.5883092784475927,-0.295,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP455-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,455.0,427.5,2.11,,,60.0,13.75,41.7,12.98,35.06,0.007287500000000001,-0.11717700000000002,43.9,1.5605507716043774,13.759099557247435,3.367077734231397e-11,0.13692749548286762,206.90600070750537,3.7616879674490944,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG455-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,455.0,428.2,2.11,,,60.0,13.75,41.7,12.98,35.06,0.006875000000000001,-0.11425800000000001,43.2,1.525118260194738,13.760225906368957,1.8079497315163905e-11,0.14302956550001877,192.32099960774403,1.2372565867958034,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG455-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,455.0,431.9,2.11,,,60.0,13.83,42.1,13.09,34.76,0.0059469,-0.10567100000000001,43.4,1.4533450608373335,13.842826383394057,3.588415719443268e-12,0.21157080560772978,228.12543155678154,-3.0966244069363076,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG455-N96R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,455.0,430.8,1.94,,,16.0,15.94,36.06,15.09,30.16,0.0066948,-0.0879864,44.9,1.249226087398142,15.952945683199227,4.574073529573533e-12,0.12850509898298854,158.22813264854426,0.5524311171827277,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP460-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,460.0,432.3,2.11,,,60.0,13.8,41.9,13.03,35.31,0.007314,-0.11773900000000001,43.9,1.5697476788820564,13.808609175134805,3.479397914257297e-11,0.12988881314722883,208.2041088715894,4.0073035241711095,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG460-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,460.0,433.0,2.11,,,60.0,13.8,41.9,13.03,35.31,0.006900000000000001,-0.114806,43.2,1.5712794416131326,13.808563863702446,3.571283026397415e-11,0.12962677844766993,208.88346888747773,6.949257563180511,-0.346,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG460-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,460.0,436.7,2.11,,,60.0,13.94,42.24,13.19,34.88,0.005994199999999999,-0.10602240000000002,43.4,1.4584700625048939,13.95328893260107,3.6366296320038128e-12,0.2102184835982366,220.51776126272122,-3.051823819890558,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG460-N96R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,460.0,435.7,1.94,,,16.0,15.99,36.3,15.14,30.39,0.006715800000000001,-0.088572,44.9,1.258014762382903,16.002641872673113,4.639185953828848e-12,0.12676292971725456,160.3353632286595,0.6432976389193327,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP465-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,465.0,437.2,2.11,,,60.0,13.85,42.1,13.08,35.56,0.007340500000000001,-0.11830100000000002,43.9,1.578940721634845,13.858123898510511,3.593970814540397e-11,0.12290683038583888,209.53728229853678,4.250051450545369,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG465-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,465.0,437.8,2.11,,,60.0,13.85,42.1,13.08,35.56,0.006925000000000001,-0.11535400000000003,43.2,1.5804694232095249,13.858080522326501,3.688028379923478e-11,0.12264590805200028,210.2149068837233,7.196697038967105,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG465-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,465.0,441.6,2.11,,,60.0,14.03,42.38,13.29,34.99,0.0060329,-0.1063738,43.4,1.4624600430324441,14.042041780633276,3.6041937073242513e-12,0.21004232729485742,244.72243326247565,-3.179843312160803,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG465-N96R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,465.0,440.5,1.94,,,16.0,16.11,36.37,15.26,30.48,0.0067662,-0.0887428,44.9,1.260817565308836,16.12212416185185,4.716352365300883e-12,0.12373610098177676,164.4145479223226,0.7167005558423123,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP470-120M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,470.0,442.0,2.11,,,60.0,13.9,42.3,13.13,35.81,0.007367,-0.11886300000000001,43.9,1.5881299254107977,13.90764387107015,3.7108023437685856e-11,0.11598084445697489,210.90540945671995,4.489975352871662,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG470-120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,470.0,442.6,2.11,,,60.0,13.9,42.3,13.13,35.81,0.006950000000000001,-0.115902,43.2,1.589655683631529,13.907602361398522,3.8070566312909955e-11,0.11572101401545283,211.58190531217673,7.4412704920258825,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG470-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,470.0,446.4,2.11,,,60.0,14.12,42.52,13.39,35.11,0.006071599999999999,-0.1067252,43.4,1.4666573353457566,14.130769285510375,3.586732039015951e-12,0.20901498372582286,274.0471105261791,-3.2744444974893456,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG470-N96R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,470.0,445.4,1.94,,,16.0,16.23,36.44,15.38,30.56,0.006816600000000001,-0.0889136,44.9,1.263426323279664,16.241667904565496,4.773272832411554e-12,0.12149542132320783,168.9995555851665,0.7531160462794085,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG475-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,475.0,451.3,2.11,,,60.0,14.2,42.66,13.48,35.24,0.006105999999999999,-0.1070766,43.4,1.4710850769399637,14.209527730618854,3.5828785094181376e-12,0.20730189962578743,308.95992970163,-3.3324981352671985,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP480-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,480.0,450.6,2.31,,,66.0,13.58,44.97,12.7,37.81,0.0071974,-0.1263657,43.9,1.6908805641285618,13.59579712900887,3.7296003550226264e-11,0.14831083897016506,127.49539520146078,4.768516117706223,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG480-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,480.0,451.3,2.31,,,66.0,13.58,44.97,12.7,37.81,0.006790000000000001,-0.1232178,43.2,1.6925011357012159,13.595738778650917,3.8259597987101494e-11,0.1480262543567912,127.72252471437307,7.72724626405462,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG480-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,480.0,456.1,2.11,,,60.0,14.29,42.8,13.57,35.38,0.0061446999999999995,-0.107428,43.4,1.476175646609183,14.299146719165527,3.6254356870063403e-12,0.20462718762878185,319.69086023666074,-3.2898195430278907,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP485-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,485.0,455.4,2.31,,,66.0,13.68,45.12,12.78,37.96,0.0072504,-0.12678720000000002,43.9,1.6979927184933814,13.696458651715755,3.839683787886454e-11,0.1454304828222502,120.87800696461464,4.957752617374595,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG485-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,485.0,456.1,2.31,,,66.0,13.68,45.12,12.78,37.96,0.006840000000000001,-0.12362880000000001,43.2,1.6996114748871136,13.696399095527694,3.938267801491576e-11,0.14514780060399005,121.08118529277058,7.9203990722683715,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG485-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,485.0,461.0,2.11,,,60.0,14.38,42.94,13.66,35.52,0.0061834,-0.1077794,43.4,1.4812670725956982,14.388772820564302,3.668267793296643e-12,0.20198763646357681,331.0887521616778,-3.2472959610882914,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP490-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,490.0,460.2,2.31,,,66.0,13.76,45.27,12.86,38.11,0.0072927999999999995,-0.12720870000000004,43.9,1.7038396544325103,13.776048179741645,3.875971615501296e-11,0.14298735477441304,122.59994863563736,4.986734132261764,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG490-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,490.0,460.9,2.31,,,66.0,13.76,45.27,12.86,38.11,0.006880000000000001,-0.12403980000000002,43.2,1.7054620203395836,13.775989306137635,3.9753536201270166e-11,0.14270570596536303,122.8089892727261,7.94986092917029,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG490-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,490.0,465.9,2.11,,,20.0,14.47,43.06,13.75,35.66,0.0062221,-0.10808060000000001,43.4,1.4859974683845767,14.47838850760361,3.735043944753039e-12,0.19791868606090096,341.4055924748905,-3.153908997093031,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP495-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,495.0,465.0,2.31,,,66.0,13.83,45.42,12.94,38.26,0.0073299,-0.12763020000000003,43.9,1.7090588768691604,13.845130070773934,3.874878026811235e-11,0.14077256265464483,128.6765001008807,4.936880023331534,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG495-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,495.0,465.7,2.31,,,66.0,13.83,45.42,12.94,38.26,0.006915000000000001,-0.12445080000000003,43.2,1.7106875309477036,13.84507281236625,3.974338928389465e-11,0.14049151863556172,128.9074438014271,7.898796662936675,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG495-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,495.0,470.7,2.11,,,20.0,14.56,43.21,13.83,35.8,0.0062607999999999995,-0.10845710000000001,43.4,1.4917524721863253,14.568898281292011,3.798823110702987e-12,0.19607854390295745,320.8376451713963,-3.0661491779012193,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP500-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,500.0,469.8,2.31,,,66.0,13.9,45.57,13.02,38.41,0.007367,-0.12805170000000002,43.9,1.7142832139584836,13.914234324754066,3.874091396845817e-11,0.1385836063775495,135.3286631316455,4.887973210685833,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG500-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,500.0,470.5,2.31,,,66.0,13.9,45.57,13.02,38.41,0.006950000000000001,-0.12486180000000001,43.2,1.715918179401232,13.91417869008867,3.9736391531926513e-11,0.13830315603963492,135.58473089250586,7.848706264609309,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG500-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,500.0,473.3,2.16,,,18.0,15.83,40.01,14.98,33.38,0.0066486,-0.0976244,44.9,1.3846650924632717,15.843685912377365,4.410764872118675e-12,0.14991614812203502,173.4025865782959,0.3093791401508106,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG500-N120M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,500.0,475.6,2.11,,,20.0,14.65,43.36,13.92,35.94,0.0062995,-0.1088336,43.4,1.4970259211203805,14.658546653212623,3.830623834250279e-12,0.19426668650382337,332.99665741161493,-3.0499726192103997,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP505-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,505.0,474.7,2.31,,,66.0,13.96,45.72,13.1,38.56,0.0073988,-0.1284732,43.9,1.7188889903962963,13.972859406090581,3.83690758662626e-11,0.13661429086052526,148.30664429358075,4.762364161901462,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG505-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,505.0,475.4,2.31,,,66.0,13.96,45.72,13.1,38.56,0.00698,-0.12527280000000002,43.2,1.720532942991279,13.972806333583442,3.9358404711550356e-11,0.13633401585446797,148.61575036834282,7.720273533591275,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG505-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,505.0,478.1,2.16,,,18.0,15.88,40.24,15.03,33.6,0.006669600000000001,-0.09818560000000001,44.9,1.3930655618853898,15.89339457908689,4.4659125323037586e-12,0.14818016695926942,175.67562515458212,0.3856675659706145,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP510-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,510.0,479.5,2.31,,,66.0,14.02,45.87,13.18,38.71,0.007430599999999999,-0.1288947,43.9,1.7235049757403365,14.031519628843672,3.800847481297212e-11,0.1346659404566993,163.89560162696603,4.638804689980005,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG510-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,510.0,480.2,2.31,,,66.0,14.02,45.87,13.18,38.71,0.00701,-0.1256838,43.2,1.7251577292196356,14.031469118891678,3.8991741450740735e-11,0.1343858694416583,164.27503463377104,7.593915953858781,-0.346,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG510-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,510.0,483.0,2.16,,,18.0,15.93,40.48,15.07,33.85,0.0066906000000000005,-0.09877119999999999,44.9,1.40265826965814,15.943740622842483,4.596812818852279e-12,0.14483639051933847,167.91405532697905,0.6018278279327215,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG510-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,510.0,484.3,2.31,,,66.0,14.01,46.53,13.29,38.45,0.0060243,-0.11679030000000001,43.4,1.6053173045453046,14.020247908483217,3.5819154209657896e-12,0.228050007800098,311.7690426519516,-3.223773874091603,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP515-132M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,515.0,484.3,2.31,,,66.0,14.08,46.02,13.26,38.86,0.0074624,-0.12931620000000002,43.9,1.7281309260409632,14.09021444034396,3.765867672682886e-11,0.13273824736714776,182.9718003430443,4.517245364284759,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG515-132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,515.0,485.0,2.31,,,66.0,14.08,46.02,13.26,38.86,0.007040000000000001,-0.12609480000000003,43.2,1.7297928246452727,14.090166485000951,3.8636279644481695e-11,0.1324583196958798,183.44719452269152,7.469653313895095,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG515-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,515.0,487.8,2.16,,,18.0,15.98,40.71,15.11,34.09,0.006711600000000001,-0.0993324,44.9,1.4118756169381104,15.994060582182852,4.727094664434846e-12,0.14159741728564645,160.92695890015307,0.8105946906411609,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG515-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,515.0,489.2,2.31,,,66.0,14.08,46.71,13.36,38.55,0.0060544,-0.1172421,43.4,1.610363885988327,14.090046795447895,3.5267353667186156e-12,0.23195189021730594,325.0670966483422,-3.3892539170732827,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP520-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,520.0,488.0,2.52,,,72.0,13.53,48.94,12.68,41.02,0.0071709,-0.13752140000000002,43.9,1.8352019662066317,13.545097546308687,3.468214094824004e-11,0.17390609615994435,155.84979512416803,4.175129362360729,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG520-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,520.0,488.8,2.52,,,72.0,13.53,48.94,12.68,41.02,0.006765,-0.1340956,43.2,1.8369919086794384,13.54503939757318,3.559671978252243e-11,0.17359212590165288,156.1699177212525,7.121861692040627,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG520-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,520.0,492.7,2.16,,,18.0,16.02,40.94,15.15,34.33,0.006728400000000001,-0.0998936,44.9,1.4206917336183542,16.033683549932842,4.820564588702996e-12,0.1384892682170563,162.13614819485662,0.9525302537061181,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG520-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,520.0,494.0,2.31,,,66.0,14.16,46.87,13.46,38.64,0.006088799999999999,-0.1176437,43.4,1.6137607588602318,14.167919922324005,3.4217005997037924e-12,0.23498093887954535,420.1215579100737,-3.6835537877973135,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP525-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,525.0,492.8,2.52,,,72.0,13.61,49.11,12.74,41.21,0.0072133,-0.1379991,43.9,1.843778137745975,13.625754903369279,3.5962123440508316e-11,0.16904437208689294,146.0303415338335,4.436719666600904,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG525-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,525.0,493.6,2.52,,,72.0,13.61,49.11,12.74,41.21,0.006805,-0.1345614,43.2,1.8040232801448326,13.62710064328889,1.997603254982529e-11,0.17602187440679,140.0916724573761,2.1801124526322724,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG525-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,525.0,497.6,2.16,,,18.0,16.13,41.02,15.27,34.39,0.0067746,-0.10008880000000002,44.9,1.4226506970592163,16.142704119334464,4.779905176163657e-12,0.13838688782632655,175.70525314180534,0.8203834594230449,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG525-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,525.0,498.9,2.31,,,66.0,14.24,47.03,13.55,38.75,0.0061232,-0.1180453,43.4,1.618098710382639,14.246664785911706,3.373692500776534e-12,0.23628905265261516,504.8558354454182,-3.8454306723059353,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP530-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,530.0,496.1,2.55,,,55.0,18.32,37.09,17.22,30.8,0.0093432,-0.10051390000000002,44.3,1.387072497202798,18.339663764672476,4.387958917733282e-11,0.11614067268649778,108.20395668154114,7.465632723202004,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP530-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,530.0,497.7,2.52,,,72.0,13.69,49.26,12.81,41.39,0.0072556999999999995,-0.1384206,43.9,1.8510321101329197,13.705727630900988,3.70067586629975e-11,0.16365410509043882,142.45150636516277,4.631587243689421,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG530-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,530.0,498.4,2.52,,,72.0,13.69,49.26,12.81,41.39,0.006845,-0.1349724,43.2,1.852813271491391,13.705668949243828,3.7967360141751564e-11,0.16334419009097165,142.7142266944642,7.587529242526731,-0.346,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG530-N108R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,530.0,502.4,2.16,,,18.0,16.24,41.1,15.38,34.47,0.0068208,-0.10028400000000001,44.9,1.425431804666934,16.25232213088649,4.815119673763471e-12,0.1367779485544075,180.26702591889372,0.8233094025578005,-0.295,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG530-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,530.0,503.7,2.31,,,66.0,14.32,47.19,13.64,38.86,0.006157599999999999,-0.1184469,43.4,1.6224443502226082,14.325386901874069,3.327034635073304e-12,0.23757750657986032,631.5522337968241,-4.005164430413652,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP535-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,535.0,500.9,2.55,,,55.0,18.37,37.29,17.27,30.99,0.009368699999999999,-0.1010559,44.3,1.3949877360925158,18.389292431872697,4.437412815082199e-11,0.11486079483619788,109.36893970489271,7.539076710684557,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP535-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,535.0,502.5,2.52,,,72.0,13.76,49.42,12.88,41.54,0.0072927999999999995,-0.13887020000000003,43.9,1.857079209996688,13.775432632030002,3.7228576270242694e-11,0.16200606731311643,144.44739539376846,4.637743194054018,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG535-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,535.0,503.2,2.52,,,72.0,13.76,49.42,12.88,41.54,0.006880000000000001,-0.13541080000000003,43.2,1.8588654094686652,13.775374403662557,3.8194490710477164e-11,0.16169690586255167,144.71777172361413,7.593733803202534,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG535-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,535.0,508.6,2.31,,,66.0,14.4,47.35,13.73,38.97,0.0061920000000000005,-0.11884850000000001,43.4,1.626797471790294,14.404086507291998,3.2816739142607084e-12,0.23884674794675823,841.6461280948752,-4.16280506541704,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP540-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,540.0,505.7,2.55,,,55.0,18.42,37.49,17.32,31.19,0.0093942,-0.1015979,44.3,1.403133393862913,18.438842416996525,4.5065618872716876e-11,0.1129234717936187,110.39190820129909,7.649948297127873,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP540-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,540.0,507.3,2.52,,,72.0,13.84,49.58,12.96,41.69,0.007335199999999999,-0.13931980000000002,43.9,1.863081081614856,13.855116506783892,3.745552365724208e-11,0.16026640179414037,146.73277663416238,4.638666497112543,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG540-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,540.0,508.1,2.52,,,72.0,13.84,49.58,12.96,41.69,0.00692,-0.1358492,43.2,1.8648725206134837,13.855058751655918,3.8427039857329646e-11,0.15995819369814473,147.01228005911642,7.59459290236825,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG540-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,540.0,513.5,2.31,,,22.0,14.48,47.5,13.82,39.08,0.0062264,-0.11922500000000001,43.4,1.6309768261888957,14.48277854915338,3.246890055240994e-12,0.2393686469835923,1247.434496431391,-4.295531798072659,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP545-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,545.0,510.6,2.55,,,55.0,18.47,37.69,17.36,31.39,0.0094197,-0.1021399,44.3,1.4116772746069803,18.489101243304155,4.607566972882952e-11,0.11096823376496447,107.30104115080353,7.821871380610505,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP545-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,545.0,512.1,2.52,,,72.0,13.92,49.74,13.03,41.83,0.007377599999999999,-0.13976940000000002,43.9,1.869578057019423,13.935440339575463,3.7915475728447955e-11,0.15932547251714954,143.63742240772982,4.694846545415932,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG545-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,545.0,512.9,2.52,,,72.0,13.92,49.74,13.03,41.83,0.00696,-0.1362876,43.2,1.871372972177687,13.935381881709825,3.889712897472792e-11,0.1590182696425693,143.90530156543096,7.651946678214972,-0.346,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG545-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,545.0,518.3,2.31,,,22.0,14.56,47.65,13.91,39.19,0.0062607999999999995,-0.1196015,43.4,1.6351630720800476,14.561457354527336,3.21301088062568e-12,0.23988165266351658,2396.5870209815575,-4.426498119269734,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP550-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,550.0,515.4,2.55,,,55.0,18.52,37.89,17.41,31.59,0.009445199999999999,-0.1026819,44.3,1.4198216907086836,18.538649014395148,4.677629551645093e-11,0.10905291525701598,108.29848604149264,7.92980841483336,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP550-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,550.0,516.9,2.52,,,72.0,14.0,49.9,13.11,41.96,0.00742,-0.140219,43.9,1.875114800710798,14.015274634110158,3.7893884333443094e-11,0.15937803084281826,146.0782908691143,4.639817779857683,-0.341,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG550-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,550.0,517.7,2.52,,,72.0,14.0,49.9,13.11,41.96,0.007000000000000001,-0.13672600000000001,43.2,1.8769177248142388,14.015216245311889,3.8876718687916567e-11,0.15907139164882408,146.3567030095648,7.595763919354628,-0.346,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG550-N132M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,550.0,523.2,2.31,,,22.0,14.64,47.8,14.0,39.3,0.0062952,-0.119978,43.4,1.6393561046275456,14.640123130641602,3.180007077517168e-12,0.2403859774802304,28581.435076393114,-4.5557346868157005,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP555-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,555.0,520.2,2.55,,,55.0,18.57,38.09,17.46,31.79,0.0094707,-0.10322390000000001,44.3,1.4279646726598092,18.588203349700848,4.7479321664504064e-11,0.10714915811706263,109.30734798503863,8.036388934547249,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP555-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,555.0,521.8,2.52,,,72.0,14.08,50.06,13.19,42.09,0.0074624,-0.14066860000000003,43.9,1.880654093722296,14.095107293172058,3.7873734911773095e-11,0.1594291529144018,148.5880005394939,4.585427842089716,-0.341,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG555-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,555.0,522.5,2.52,,,72.0,14.08,50.06,13.19,42.09,0.007040000000000001,-0.13716440000000002,43.2,1.8824650088670905,14.095048970849398,3.885776444886754e-11,0.15912307205402043,148.87748073786284,7.540235297572142,-0.346,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG555-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,555.0,527.0,2.52,,,72.0,14.01,50.7,13.26,41.86,0.0060243,-0.127257,43.4,1.750237355986375,14.023028365360052,3.6355756904487826e-12,0.25156915025274973,270.52386844594855,-3.095507433564844,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP560-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,560.0,525.0,2.55,,,55.0,18.62,38.29,17.51,31.99,0.0094962,-0.10376590000000001,44.3,1.4361062319709974,18.6377641857576,4.818468677853241e-11,0.1052568562845188,110.32775191991888,8.141631500505488,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP560-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,560.0,526.6,2.52,,,72.0,14.16,50.22,13.27,42.23,0.0075048,-0.1411182,43.9,1.8864288981862067,14.174867573903787,3.797885449079695e-11,0.15861138243091144,151.06278966659778,4.559423611054067,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG560-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,560.0,527.4,2.52,,,72.0,14.16,50.22,13.27,42.23,0.00708,-0.1376028,43.2,1.8882464009568447,14.174809517256664,3.896630620918756e-11,0.15830603936496937,151.36303851040978,7.513641797111512,-0.346,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG560-N120R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,560.0,530.2,2.4,,,20.0,15.91,44.56,15.02,37.29,0.0066822,-0.10872640000000001,44.9,1.546042555788047,15.925834937061643,4.754727699809282e-12,0.15741256050850522,158.15874923466092,0.9024135639570855,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG560-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,560.0,531.9,2.52,,,72.0,14.07,50.84,13.34,41.99,0.0060501,-0.1276084,43.4,1.7539915734672553,14.080949082187463,3.5938476478012553e-12,0.2499533176284618,321.19981596170913,-3.22933207633602,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP565-110M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,565.0,529.8,2.55,,,55.0,18.67,38.49,17.56,32.18,0.009521700000000001,-0.10430790000000001,44.3,1.4440155087425572,18.687418290142233,4.868589229815779e-11,0.10403151539203749,111.50740970467011,8.20835175099991,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP565-144M10T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,565.0,531.4,2.52,,,72.0,14.24,50.38,13.34,42.36,0.0075472,-0.14156780000000002,43.9,1.8926897904312185,14.255265655420187,3.8311931322402114e-11,0.15856491013648874,147.91139135050963,4.587131493145909,-0.341,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG565-144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,565.0,532.2,2.52,,,72.0,14.24,50.38,13.34,42.36,0.0071200000000000005,-0.13804120000000003,43.2,1.8945121879509306,14.255206700674941,3.930727911713975e-11,0.15826034896977184,148.19962802558854,7.541968475113318,-0.346,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG565-N120R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,565.0,535.0,2.4,,,20.0,15.95,44.79,15.06,37.52,0.006699000000000001,-0.1092876,44.9,1.5546577474505996,15.965497253549156,4.823545611350472e-12,0.15499986250185072,159.52812554135383,1.0008207755186556,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG565-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,565.0,536.7,2.52,,,72.0,14.13,50.98,13.41,42.13,0.0060758999999999995,-0.1279598,43.4,1.758539306431547,14.13977894183363,3.5963214417979672e-12,0.24750454215319567,357.6296136557897,-3.26180739856199,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG570-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,570.0,541.6,2.52,,,72.0,14.2,51.13,13.49,42.26,0.006105999999999999,-0.12833630000000001,43.4,1.7630434426496084,14.208606658820258,3.5786812785740735e-12,0.24649856720920238,406.69436745899503,-3.3448261509902495,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG575-N120R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,575.0,544.7,2.4,,,20.0,16.03,45.25,15.14,37.98,0.006732600000000002,-0.11041,44.9,1.5718844389258055,16.04483537213517,4.96183921591031e-12,0.15021465479478252,162.31078649958712,1.1940890201114795,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG575-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,575.0,546.4,2.52,,,72.0,14.27,51.28,13.56,42.41,0.006136099999999999,-0.12871280000000002,43.4,1.768528867967265,14.27831637440047,3.6157182160728213e-12,0.24382279242922014,418.37357133016843,-3.302737282104706,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP580-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,580.0,543.1,2.76,,,60.0,18.32,40.7,17.27,33.6,0.0093432,-0.11029700000000002,44.3,1.515354993738814,18.33698869728221,3.912728287532187e-11,0.1407801378408633,151.8122378097419,6.457496815958151,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG580-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,580.0,543.8,2.76,,,60.0,18.32,40.7,17.27,33.6,0.0097096,-0.11029700000000002,43.8,1.523329966907848,18.3365537835834,4.504584387958338e-11,0.1397678997090543,154.68052606951238,7.652168998582947,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG580-N120R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,580.0,549.6,2.4,,,20.0,16.12,45.35,15.23,38.09,0.006770400000000001,-0.110654,44.9,1.57563478530494,16.134432730708845,5.016588775682522e-12,0.14777717465866863,165.0531768391003,1.2377030454953044,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG580-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,580.0,551.3,2.52,,,72.0,14.34,51.43,13.63,42.56,0.006166199999999999,-0.1290893,43.4,1.774014658449343,14.348030823498693,3.652947037821142e-12,0.24117455752829992,430.64612901526084,-3.2608513058554305,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP585-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,585.0,547.9,2.76,,,60.0,18.37,40.9,17.31,33.8,0.009368699999999999,-0.11083900000000001,44.3,1.5239119305734594,18.38744182583946,3.9986001887181826e-11,0.13875043556299052,146.13410029604805,6.62359838262026,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG585-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,585.0,548.6,2.76,,,60.0,18.37,40.9,17.31,33.8,0.0097361,-0.11083900000000001,43.8,1.5319349648604632,18.387006617676263,4.6032137001263416e-11,0.13773357672009187,148.77536969088143,7.819606799855146,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG585-N120R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,585.0,554.5,2.4,,,20.0,16.22,45.42,15.31,38.22,0.0068124,-0.11082480000000001,44.9,1.5801541869185383,16.235045559200117,5.236671164512841e-12,0.14175165376834817,152.81663897536555,1.549649325711957,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG585-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,585.0,556.2,2.52,,,72.0,14.41,51.58,13.7,42.72,0.0061963,-0.12946580000000002,43.4,1.779698821212789,14.417743338542747,3.702206772532547e-12,0.23772219070879966,442.39016015358607,-3.193468007386802,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP590-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,590.0,552.7,2.76,,,60.0,18.42,41.1,17.35,34.0,0.0093942,-0.11138100000000002,44.3,1.532471490994656,18.43787031090674,4.0856366326291006e-11,0.1367296632961923,140.935452611314,6.788463724216482,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG590-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,590.0,553.4,2.76,,,60.0,18.42,41.1,17.35,34.0,0.009762600000000001,-0.11138100000000002,43.8,1.5405425765840381,18.4374347463987,4.70317283258743e-11,0.13570820583230767,143.37720329851362,7.9857929472718565,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG590-N120R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,590.0,559.3,2.4,,,20.0,16.32,45.49,15.38,38.37,0.006854400000000001,-0.1109956,44.9,1.5855460086868531,16.3360380553345,5.54762932751864e-12,0.13426610126330527,136.62646307207385,1.989562934041063,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG590-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,590.0,561.0,2.52,,,24.0,14.48,51.7,13.77,42.87,0.0062264,-0.129767,43.4,1.784641751025934,14.487452194672882,3.769674908056648e-12,0.23293998377225242,452.6144507477916,-3.0883882392415405,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP595-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,595.0,557.5,2.76,,,60.0,18.47,41.3,17.4,34.2,0.0094197,-0.11192300000000001,44.3,1.5406034960726471,18.48748878843624,4.1455294023315064e-11,0.13474061487619973,142.30026222898934,6.890713145393633,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG595-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,595.0,558.2,2.76,,,60.0,18.47,41.3,17.4,34.2,0.0097891,-0.11192300000000001,43.8,1.5487192668763732,18.487058683626753,4.771975650665814e-11,0.13371572552914632,144.778432597657,8.088892477223652,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG595-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,595.0,565.9,2.52,,,24.0,14.55,51.84,13.83,43.03,0.0062565,-0.13011840000000002,43.4,1.7907228307311966,14.558005789352103,3.8626719257572415e-12,0.22882619255488226,415.8766578871278,-2.929388704602487,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP600-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,600.0,562.3,2.76,,,60.0,18.52,41.5,17.45,34.4,0.009445199999999999,-0.11246500000000002,44.3,1.5487341624444004,18.537112507512425,4.205654452728449e-11,0.1327635384865808,143.6832535796347,6.991784676636022,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG600-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,600.0,563.0,2.76,,,60.0,18.52,41.5,17.45,34.4,0.0098156,-0.11246500000000002,43.8,1.5568945958191538,18.536687815916146,4.84104239063896e-11,0.13173524141993245,146.19868233198684,8.190801265713008,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG600-N144M10,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,600.0,570.8,2.52,,,24.0,14.62,51.97,13.9,43.18,0.006286599999999999,-0.13044470000000002,43.4,1.7958459573615744,14.627719074857069,3.921814516491625e-12,0.22485849017665266,425.88408740427195,-2.8467456305691323,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP605-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,605.0,567.1,2.76,,,60.0,18.57,41.7,17.49,34.6,0.0094707,-0.11300700000000002,44.3,1.557296647759477,18.58749874421748,4.29501749668957e-11,0.13077257326764638,138.77834191072276,7.152932775483302,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG605-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,605.0,567.8,2.76,,,60.0,18.57,41.7,17.49,34.6,0.0098421,-0.11300700000000002,43.8,1.5655050804465056,18.58707354484662,4.9436557081748524e-11,0.12973974561735818,141.11112381489497,8.35323373804964,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP610-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,610.0,572.0,2.76,,,60.0,18.62,41.9,17.53,34.8,0.0094962,-0.113549,44.3,1.5658617052430415,18.637861875345372,4.38554970732171e-11,0.1287902587157892,134.25659917393907,7.312917684599371,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG610-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,610.0,572.6,2.76,,,60.0,18.62,41.9,17.53,34.8,0.0098686,-0.113549,43.8,1.5741181338518426,18.637436110807382,5.047603981933742e-11,0.1277529232332627,136.4271785770208,8.514482987595372,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP615-120M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,615.0,576.8,2.76,,,60.0,18.67,42.1,17.57,35.01,0.009521700000000001,-0.11409100000000003,44.3,1.5746606126140514,18.688132930927043,4.4947500475306764e-11,0.1261608410772416,129.89752912020737,7.505818592729851,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG615-120M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,615.0,577.5,2.76,,,60.0,18.67,42.1,17.57,35.01,0.009895100000000002,-0.11409100000000003,43.8,1.582966843055984,18.687707926334006,5.1729708107140825e-11,0.12511857223749437,131.9162813200173,8.708911005685271,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG620-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,620.0,587.1,2.63,,,22.0,15.92,49.25,15.05,41.2,0.0066864,-0.12017,44.9,1.7074097806992403,15.934429556863408,4.65763834499078e-12,0.17505632940237478,193.13806951914106,0.7194519623995287,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG625-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,625.0,592.0,2.63,,,22.0,15.96,49.49,15.08,41.45,0.006703200000000001,-0.1207556,44.9,1.7171048041243098,15.974795210667102,4.775021315124848e-12,0.1717310136591995,185.25095954845239,0.9082576184653397,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SPDG630-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,630.0,596.8,2.63,,,22.0,15.99,49.73,15.11,41.7,0.006715800000000001,-0.12134119999999998,44.9,1.726310642105261,16.004467904328365,4.854813488184374e-12,0.16855777554685591,186.29088902346575,1.0305176496906596,-0.295,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP635-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,635.0,594.5,3.04,,,66.0,18.32,44.64,17.28,36.75,0.0093432,-0.12097440000000001,44.3,1.6592120085267184,18.336566620911015,3.740620572234007e-11,0.1612789285905417,178.34837992254913,6.066395099876641,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG635-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,635.0,595.2,3.04,,,66.0,18.32,44.64,17.28,36.75,0.0097096,-0.12097440000000001,43.8,1.6679361335148193,18.33612376661672,4.306937045383352e-11,0.16017468822040176,181.99223401778028,7.257871627524627,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG635-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,635.0,601.7,2.63,,,22.0,16.03,49.97,15.14,41.95,0.006732600000000002,-0.12192679999999999,44.9,1.7360108652682111,16.044791920877156,4.975272714403301e-12,0.16525777259659952,179.08979637819016,1.2167126187039194,-0.295,N,2025.7.3,6/23/2025,2.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP640-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,640.0,599.3,3.04,,,66.0,18.36,44.85,17.31,36.97,0.009363599999999998,-0.12154350000000001,44.3,1.6684656332045464,18.37707872666636,3.8348540720427105e-11,0.15853432375614843,170.42782354471842,6.264172419503623,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG640-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,640.0,600.0,3.04,,,66.0,18.36,44.85,17.31,36.97,0.0097308,-0.12154350000000001,43.8,1.677242471849433,18.376636731785496,4.4151798974541806e-11,0.15742416899190376,173.7305027971069,7.457255153105281,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG640-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,640.0,606.6,2.63,,,22.0,16.12,50.05,15.23,42.03,0.006770400000000001,-0.12212199999999998,44.9,1.7387814150528489,16.134471262360186,5.004263927651523e-12,0.16365896542052905,182.30493009743623,1.2171155399116504,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP645-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,645.0,604.1,3.04,,,66.0,18.4,45.06,17.35,36.18,0.009384,-0.12211260000000003,44.3,1.653745274724419,18.41938474596683,2.6723955678909484e-11,0.22306769198901383,211.73584442105346,3.1647038743373725,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG645-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,645.0,604.8,3.04,,,66.0,18.4,45.06,17.35,36.18,0.009752,-0.12211260000000003,43.8,1.6623744752958802,18.418805058284043,3.079218566497028e-11,0.2220005457677601,217.21868874691384,4.33125981706518,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG645-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,645.0,611.4,2.63,,,22.0,16.2,50.14,15.32,42.11,0.006804000000000001,-0.12234160000000001,44.9,1.741244933929029,16.213552518312035,4.97968917431076e-12,0.16287151795125737,194.68842851929375,1.1305992100922095,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP650-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,650.0,608.9,3.04,,,66.0,18.44,45.27,17.39,36.38,0.0094044,-0.12268170000000002,44.3,1.6620867426607489,18.459119977272394,2.706357518193107e-11,0.2215258109255713,213.64753507733937,3.2522513287130583,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG650-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,650.0,609.7,3.04,,,66.0,18.44,45.27,17.39,36.38,0.009773200000000001,-0.12268170000000002,43.8,1.670761681709112,18.45854514044203,3.1182932463485785e-11,0.22045477506598077,219.20492519187948,4.419590705341095,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG650-N132R12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,650.0,616.3,2.63,,,22.0,16.28,50.23,15.41,42.19,0.006837600000000002,-0.1225612,44.9,1.743716066842943,16.29263760784642,4.9558286519640514e-12,0.16209122974575105,208.8089180301167,1.0453863870093143,-0.295,N,2025.7.3,6/23/2025,4.0,first_pass +Zhejiang Sunpro Power Technology Co Ltd SP655-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,655.0,613.7,3.04,,,66.0,18.48,45.48,17.43,37.58,0.0094248,-0.12325080000000001,44.3,1.6936782472151655,18.49623401097694,3.971145727669579e-11,0.15373067223784737,174.99944142987096,6.508520897275808,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG655-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,655.0,614.5,3.04,,,66.0,18.48,45.48,17.43,37.58,0.0097944,-0.12325080000000001,43.8,1.7025927612556702,18.495805103709163,4.5717805714874376e-11,0.15260894964913205,178.43688189862036,7.703651600945094,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP660-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,660.0,618.5,3.04,,,66.0,18.52,45.69,17.47,37.79,0.009445199999999999,-0.1238199,44.3,1.7022342129722416,18.5359307594668,4.0264179579919474e-11,0.15170520595126696,176.3619901465902,6.6090833102215205,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG660-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,660.0,619.3,3.04,,,66.0,18.52,45.69,17.47,37.79,0.0098156,-0.1238199,43.8,1.7111958172255837,18.535507012244473,4.635278386429927e-11,0.1505793655484618,179.83669840391892,7.805052903443939,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP665-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,665.0,623.4,3.04,,,66.0,18.56,45.91,17.5,38.01,0.0094656,-0.1244161,44.3,1.7116744127546242,18.57641268481791,4.112046473102787e-11,0.14958477397777672,169.15534929831156,6.77466577527075,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG665-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,665.0,624.1,3.04,,,66.0,18.56,45.91,17.5,38.01,0.0098368,-0.1244161,43.8,1.7206890660871568,18.575988432405396,4.7336144061486343e-11,0.14845326083776253,172.33037508510753,7.971960962419775,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP670-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,670.0,628.2,3.04,,,66.0,18.6,46.13,17.53,38.22,0.009486000000000001,-0.12501230000000002,44.3,1.7208871455171861,18.616919212269472,4.1838515492836183e-11,0.14812829572505423,162.84365277921063,6.908058176579721,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG670-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,670.0,628.9,3.04,,,66.0,18.6,46.13,17.53,38.22,0.009858,-0.12501230000000002,43.8,1.7299529993092364,18.616493107475254,4.816072247721781e-11,0.14699157935596724,165.76884683384176,8.10641165730242,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP675-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,675.0,633.0,3.04,,,66.0,18.64,46.34,17.56,38.44,0.0095064,-0.1255814,44.3,1.7301527124333818,18.65731021586912,4.28416360236822e-11,0.14544420041038789,156.61733751318448,7.097213033087057,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG675-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,675.0,633.7,3.04,,,66.0,18.64,46.34,17.56,38.44,0.0098792,-0.1255814,43.8,1.7392711638311182,18.656884541133085,4.931251393108679e-11,0.1443017222127493,159.30454431558738,8.297075225267612,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SP680-132M12T,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,680.0,637.8,3.04,,,66.0,18.68,46.56,17.59,38.66,0.009526799999999998,-0.1261776,44.3,1.739603424514055,18.697718163958886,4.373230739709618e-11,0.14334338049558165,151.12482186040987,7.259547792900839,-0.348,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhejiang Sunpro Power Technology Co Ltd SPDG680-132M12,Zhejiang Sunpro Power Technology Co Ltd,Mono-c-Si,0,680.0,638.6,3.04,,,66.0,18.68,46.56,17.59,38.66,0.0099004,-0.1261776,43.8,1.7487749264109218,18.69729179379837,5.033513564975562e-11,0.14219529125410832,153.61090346374374,8.460678118130208,-0.351,N,2025.7.3,6/23/2025,4.0,bootstrapping +Zhongshan Ruike New Energy Co Ltd RK-75-2,Zhongshan Ruike New Energy Co Ltd,CdTe,0,75.0,70.4,0.72,,,73.0,2.1,58.5,1.8,42.1,0.0012579000000000002,-0.1733355,43.7,1.999696379085755,2.160051985175053,3.701350394919636e-13,5.904575536070387,206.4812449948176,-20.62262507732682,-0.2863,N,2025.7.3,6/23/2025,4.0,first_pass +Zhongshan Ruike New Energy Co Ltd RK-95,Zhongshan Ruike New Energy Co Ltd,CdTe,0,95.0,88.2,0.72,,,146.0,1.28,116.4,1.1,86.3,0.000687104,-0.3794640000000001,44.88,4.241081663967465,1.3091928702610705,1.3774201585859167e-12,16.125063772581143,707.0247485029615,-16.237755844493833,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +Zhongshan Ruike New Energy Co Ltd RK-100,Zhongshan Ruike New Energy Co Ltd,CdTe,0,100.0,93.0,0.72,,,146.0,1.3,118.2,1.13,88.2,0.00069784,-0.38533200000000006,44.88,4.298011142736522,1.325013487972355,1.340986311959539e-12,15.427789326996942,801.8124565643086,-16.545863095138586,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +Zhongshan Ruike New Energy Co Ltd RK-105,Zhongshan Ruike New Energy Co Ltd,CdTe,0,105.0,97.7,0.72,,,146.0,1.32,120.1,1.16,90.6,0.000708576,-0.39152600000000004,44.88,4.371184330004891,1.3406264328608724,1.4134998956448643e-12,14.342780155302412,917.8741680673751,-16.30954531650068,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +Zhongshan Ruike New Energy Co Ltd RK-105-2,Zhongshan Ruike New Energy Co Ltd,CdTe,0,105.0,99.1,0.72,,,73.0,2.6,59.1,2.4,45.8,0.0016692,-0.18657870000000001,43.6,2.0499262322113485,2.6130223313620036,7.575486079889669e-13,2.969845372397722,592.9505072944962,-22.56070474238669,-0.2852,N,2025.7.3,6/23/2025,4.0,first_pass +Zhongshan Ruike New Energy Co Ltd RK-110,Zhongshan Ruike New Energy Co Ltd,CdTe,0,110.0,102.4,0.72,,,146.0,1.34,121.6,1.18,93.1,0.0007193120000000001,-0.396416,44.88,4.460275567314498,1.3584705141162976,1.77548411969206e-12,12.914255303839749,936.9041964447465,-14.8430605146369,-0.3299,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-220/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,220.0,196.9,1.6367999999999998,1.65,0.992,60.0,8.13,36.87,7.6,28.95,0.004878,-0.121671,47.1,1.5041946939204935,8.141174351340343,1.8184716159053774e-10,0.4699351516726782,341.9056188219818,5.407987998001239,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-225/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,225.0,197.8,1.6367999999999998,1.65,0.992,10.0,8.07,37.0,7.58,29.7,0.004035,-0.13949,46.8,1.63943634412393,8.073120502907312,1.2685731983413737e-09,0.34295553011769375,886.9262972085714,8.03181557733489,-0.517,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-225/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,225.0,201.5,1.6367999999999998,1.65,0.992,60.0,8.22,37.04,7.72,29.15,0.004932000000000001,-0.12223200000000001,47.1,1.5095723827145795,8.226192551675677,1.8021163073816764e-10,0.4562452035263379,605.620585698233,5.222802590499681,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-230/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,230.0,202.3,1.6367999999999998,1.65,0.992,10.0,8.22,37.1,7.7,29.9,0.004110000000000001,-0.139867,46.8,1.6503375127843298,8.22531723838929,1.40640772834441e-09,0.3188093551229078,492.85275665612915,8.789675485082878,-0.517,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-230/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,230.0,206.1,1.6367999999999998,1.65,0.992,60.0,8.31,37.21,7.84,29.35,0.004986,-0.12279300000000001,47.1,1.5150194308535965,8.311465215868107,1.7877575418841194e-10,0.44294734214026193,2512.1867908415124,5.047861363593646,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-235/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,235.0,206.9,1.6367999999999998,1.65,0.992,10.0,8.25,37.8,7.78,30.2,0.004125,-0.142506,46.8,1.666934458705435,8.253983329914671,1.1706986388245115e-09,0.3646522570396759,999999.978661299,7.119397004445584,-0.517,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-235/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,235.0,210.7,1.6367999999999998,1.65,0.992,60.0,8.39,37.38,7.95,29.55,0.005034,-0.12335400000000002,47.1,1.524622564901821,8.390003521725365,1.887671297496492e-10,0.4195326987709062,999999.4284925059,5.42372812195324,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-D60-235/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,235.0,210.3,1.6288719999999999,1.652,0.986,60.0,8.3,37.33,7.95,29.55,0.004897,-0.1258021,47.0,1.5479588725361333,8.300272603012575,2.790168322921048e-10,0.36072088286457066,10983.009210109374,6.631766746266148,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-240/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,240.0,211.4,1.6367999999999998,1.65,0.992,10.0,8.4,37.9,7.92,30.3,0.004200000000000001,-0.142883,46.8,1.6719644348151805,8.40191968849872,1.201745705904497e-09,0.35614721406509287,999999.7770357389,7.192441639375623,-0.517,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-D60-240/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,240.0,215.3,1.6288719999999999,1.652,0.986,60.0,8.46,37.52,7.92,30.31,0.004737600000000001,-0.12606720000000002,46.8,1.5633676556991611,8.469087918362927,3.1527955983499404e-10,0.33034455277113767,307.5198617780224,7.920864765551258,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-240/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,240.0,215.3,1.6367999999999998,1.65,0.992,60.0,8.47,37.55,8.07,29.75,0.005082000000000001,-0.12391500000000001,47.1,1.5370663448985742,8.470003263063267,2.0807381853924877e-10,0.3850686136042001,999998.9891083814,6.1743189517369865,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-D60-240/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,240.0,214.9,1.6288719999999999,1.652,0.986,60.0,8.42,37.5,8.07,29.74,0.0049678,-0.12637500000000002,47.0,1.5568369380461955,8.420265971482198,2.9118404793217453e-10,0.3466066492528253,10972.77621714974,6.876023133420366,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-245/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,245.0,216.0,1.6367999999999998,1.65,0.992,10.0,8.59,38.1,8.07,30.4,0.004295,-0.14363700000000001,46.8,1.6818871073091424,8.592864545601834,1.2422742395223776e-09,0.35887736097385964,1076.178905726158,7.2993389967060445,-0.517,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-D60-245/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,245.0,219.9,1.6288719999999999,1.652,0.986,60.0,8.61,37.62,8.06,30.4,0.0048216,-0.1264032,46.8,1.567852846860137,8.61927463676291,3.224056656385296e-10,0.3241013712377587,300.8757491758601,7.962804590870682,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-245/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,245.0,219.9,1.6367999999999998,1.65,0.992,60.0,8.53,37.72,8.18,29.95,0.005118,-0.124476,47.1,1.5507913371579747,8.53026634717372,2.330313910826126e-10,0.34305427339815814,10986.66519375064,7.089893109230708,-0.44,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-D60-245/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,245.0,219.5,1.6288719999999999,1.652,0.986,60.0,8.52,37.64,8.18,29.95,0.0050268,-0.1268468,47.0,1.5663821896204801,8.520249291631588,3.1205194786546226e-10,0.32180472247317793,10998.333501112422,7.372785593259622,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-250/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,250.0,220.5,1.6367999999999998,1.65,0.992,10.0,8.71,38.2,8.2,30.5,0.004355,-0.14401400000000003,46.8,1.6850479750609622,8.711029531286643,1.2416045342202482e-09,0.35200581327376435,2978.04422686731,7.1667915178649855,-0.517,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-D60-250/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,250.0,224.5,1.6288719999999999,1.652,0.986,60.0,8.75,37.72,8.2,30.49,0.004900000000000001,-0.1267392,46.8,1.571385556375506,8.758512850709852,3.248980402734432e-10,0.3185038481846525,327.37674161707736,7.88554263397734,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-250/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,250.0,222.6,1.6367999999999998,1.65,0.992,10.0,8.59,37.9,8.29,30.15,0.0052399000000000005,-0.139851,47.0,1.634025972162917,8.5900023528601,7.25869276990183e-10,0.27362919183531315,999991.608860106,4.830717533922316,-0.476,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-D60-250/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,250.0,224.1,1.6288719999999999,1.652,0.986,60.0,8.61,37.8,8.29,30.15,0.005079899999999999,-0.127386,47.0,1.5769851635274903,8.610229776001724,3.3488488750401487e-10,0.2949487306996206,11052.169618837472,7.895495580531185,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-255/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,255.0,225.1,1.6367999999999998,1.65,0.992,10.0,8.83,38.3,8.34,30.6,0.0044150000000000005,-0.144391,46.8,1.6888921028143655,8.848053787582817,1.2534134735739865e-09,0.34461799057411135,999999.9790760622,7.10954616364572,-0.517,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-D60-255/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,255.0,229.1,1.6288719999999999,1.652,0.986,60.0,8.88,37.83,8.33,30.62,0.0049728,-0.1271088,46.8,1.5763693293465526,8.887773508699624,3.320821962358692e-10,0.30899316527421483,352.9757237562511,7.944612116036663,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-255/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,255.0,227.2,1.6367999999999998,1.65,0.992,10.0,8.65,38.08,8.41,30.33,0.0052765,-0.14051519999999998,47.0,1.6489092539712413,8.650001893259526,8.079675207192219e-10,0.21866755328746915,999991.6992986238,5.6860613868258305,-0.476,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-D60-255/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,255.0,228.7,1.6288719999999999,1.652,0.986,60.0,8.71,37.95,8.41,30.33,0.0051389,-0.12789150000000002,47.0,1.5871175007175202,8.710305727738687,3.591298500021687e-10,0.26797046595507146,7634.274804057068,8.40595725981667,-0.45,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-260/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,260.0,233.2,1.6367999999999998,1.65,0.992,10.0,8.95,38.4,8.46,30.72,0.005012,-0.12288,47.0,1.5866672241878914,8.950534597499002,2.759866188790552e-10,0.3611483854038618,6046.208475804109,11.59622799172094,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-D60-260/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,260.0,233.7,1.6288719999999999,1.652,0.986,60.0,8.99,37.91,8.47,30.7,0.0050344000000000005,-0.1273776,46.8,1.5765342482164744,8.994266623148416,3.2201218933273914e-10,0.3039966113590364,640.5371190767554,7.553962499326146,-0.448,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-60-260/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,260.0,231.8,1.6367999999999998,1.65,0.992,10.0,8.72,38.26,8.52,30.53,0.0053192000000000005,-0.14117939999999998,47.0,1.6633529838633132,8.720210569294487,8.927385934462469e-10,0.16601680869909738,6875.00966336509,6.477443518238534,-0.476,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-265/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,265.0,237.8,1.6367999999999998,1.65,0.992,10.0,9.07,38.5,8.59,30.84,0.0050792,-0.1232,47.0,1.5913275819400323,9.081357557089664,2.8247914954620027e-10,0.35137390451158335,999999.9793457174,11.673208381513211,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-265/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,265.0,232.2,1.941344,1.957,0.992,12.0,8.22,44.14,7.4,35.8,0.0039456000000000005,-0.1712632,47.0,2.030978388718093,8.250071685319272,2.827315578009745e-09,0.33185267322593287,90.71090199934171,12.042320045130312,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-265/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,265.0,237.3,1.941344,1.957,0.992,72.0,8.18,44.33,7.49,35.4,0.004908,-0.146289,47.1,1.8464305137242087,8.209620725670945,2.945102940578824e-10,0.4696119446697326,129.68709860239554,9.617729386058267,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-270/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,270.0,242.4,1.6367999999999998,1.65,0.992,10.0,9.17,38.6,8.72,30.97,0.0051352,-0.12352,47.0,1.6006859225611083,9.170002951096635,3.086761005566987e-10,0.32164184979920435,999999.9355938208,12.386623851519692,-0.453,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-270/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,270.0,236.7,1.941344,1.957,0.992,12.0,8.33,44.39,7.5,36.0,0.0039984,-0.1722332,47.0,2.042214039004407,8.36043420659499,2.857489972055429e-09,0.32980654558324557,90.26978404953725,12.017305663848122,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-270/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,270.0,241.9,1.941344,1.957,0.992,72.0,8.27,44.42,7.58,35.6,0.004961999999999999,-0.14658600000000002,47.1,1.8531193719608763,8.29798933933012,3.095485935829044e-10,0.4454080893074375,131.60457664698413,9.960963582706425,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-275/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,275.0,241.2,1.941344,1.957,0.992,12.0,8.44,44.64,7.6,36.2,0.0040512000000000005,-0.1732032,47.0,2.053452304306125,8.470797036597707,2.8876403117017906e-09,0.32781302613411867,89.83795146652201,11.992809002066446,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-275/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,275.0,246.5,1.941344,1.957,0.992,72.0,8.37,44.42,7.66,35.9,0.0050219999999999996,-0.14658600000000002,47.1,1.8639110684899436,8.396916062038098,3.589155929860552e-10,0.39353941462630215,122.37767579325627,11.185675312597956,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-280/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,280.0,245.8,1.941344,1.957,0.992,12.0,8.52,45.01,7.67,36.5,0.0040896,-0.1746388,47.0,2.0708145934082833,8.551255063333468,2.924550408874919e-09,0.32735978435889407,89.23693660254003,12.023616854550816,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-280/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,280.0,251.1,1.941344,1.957,0.992,72.0,8.42,44.5,7.76,36.1,0.005052,-0.14685,47.1,1.864166223867724,8.440684215091261,3.498094116738697e-10,0.37201316729803885,151.43678820657198,10.878860760384951,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-285/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,285.0,264.1,1.64,,,60.0,9.59,38.59,8.95,31.85,0.0036729700000000002,-0.10307389,45.0,1.4490836447893092,9.606236531530113,2.542359429789691e-11,0.25408230292851336,150.07203338055228,10.141735000290867,-0.3632,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-285/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,285.0,250.3,1.941344,1.957,0.992,12.0,8.56,45.38,7.78,36.6,0.0041088,-0.17607440000000002,47.0,2.0683262520912926,8.587477309295824,2.423311763451579e-09,0.36201617149427145,112.77885123390185,10.23877160304861,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-285/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,285.0,255.7,1.941344,1.957,0.992,72.0,8.48,44.5,7.85,36.3,0.005088,-0.14685,47.1,1.8656548926341745,8.496382224675997,3.607622625605172e-10,0.33981103084039765,175.89783026499782,11.078562033878521,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-290/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,290.0,268.8,1.64,,,60.0,9.66,38.86,9.02,32.16,0.00369978,-0.10379506000000001,45.0,1.4609031110755537,9.675386463274045,2.6414934717948237e-11,0.24288079607985943,152.4865373143987,10.416566429543574,-0.3632,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-290/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,290.0,254.8,1.941344,1.957,0.992,12.0,8.59,45.77,7.88,36.8,0.0041232000000000005,-0.1775876,47.0,2.070499002835605,8.611686232426026,2.0854001153131206e-09,0.38319999775133556,151.78704863717405,8.833062649360558,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-290/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,290.0,260.3,1.941344,1.957,0.992,72.0,8.52,44.6,7.95,36.5,0.005111999999999999,-0.14718,47.1,1.8652793758983817,8.530611560411394,3.450399236772798e-10,0.32255044874729866,258.9751193368536,10.609534380308173,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-295/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,295.0,271.4,1.65,,,60.0,9.65,39.5,9.14,32.3,0.0041109,-0.10621549999999999,47.4,1.4603615942018509,9.655504290370164,1.7160476313414823e-11,0.29861777446714577,523.5300802575676,5.800905161413808,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-295/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,295.0,259.4,1.941344,1.957,0.992,12.0,8.62,46.0,7.97,37.0,0.0041376,-0.17848,47.0,2.0719101787543193,8.635564579991492,1.9193191390228758e-09,0.3827610188178714,211.98140760461072,8.042715487977441,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-295/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,295.0,264.9,1.941344,1.957,0.992,72.0,8.55,44.82,8.02,36.8,0.00513,-0.147906,47.1,1.8726937850205803,8.556980235914658,3.404495195113318e-10,0.3061956683677839,375.05513929927594,10.440331906875787,-0.44,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-300/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,300.0,276.2,1.65,,,60.0,9.75,39.7,9.24,32.5,0.0041535,-0.1067533,47.4,1.4681966910629678,9.75505309992521,1.7489415630155378e-11,0.29250430141486616,564.3895905467022,5.873307290911703,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-300/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,300.0,263.9,1.941344,1.957,0.992,12.0,8.66,46.19,8.06,37.2,0.0041567999999999996,-0.1792172,47.0,2.0742458396252315,8.670338614430202,1.8181195776981432e-09,0.3765040502628883,315.37371716884024,7.5047946721441985,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-300/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,300.0,267.2,1.941344,1.957,0.992,12.0,8.64,44.95,8.12,36.95,0.0052704,-0.1658655,47.0,1.9587069195494664,8.644236098654174,9.250602893294791e-10,0.27715636911198505,565.2919059010766,6.889196588919,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-305/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,305.0,280.9,1.65,,,60.0,9.85,39.9,9.33,32.7,0.0041961,-0.1072911,47.4,1.47677890543816,9.855551965122277,1.804370877865228e-11,0.2865063033714454,508.30419119710155,6.056211203859471,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-305/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,305.0,268.5,1.941344,1.957,0.992,12.0,8.73,46.26,8.13,37.5,0.0041904,-0.1794888,47.0,2.0850541924901753,8.73940852080279,1.9889889173492918e-09,0.33826689305245844,313.87207268586064,8.224063507742411,-0.524,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-305/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,305.0,271.8,1.941344,1.957,0.992,12.0,8.74,45.04,8.22,37.09,0.0053314,-0.1661976,47.0,1.9639083330383502,8.743813942321603,9.505058998675196e-10,0.26518283542065374,607.6912196520406,7.023024596157917,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-310/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,310.0,285.6,1.65,,,60.0,9.95,40.1,9.43,32.9,0.0042387,-0.10782889999999999,47.4,1.484615735208904,9.955112199556828,1.8381584129253558e-11,0.28064498004633837,546.2262506005515,6.126862766660116,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-310/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,310.0,278.0,1.941344,1.957,0.992,12.0,8.82,46.36,8.22,37.72,0.0049392,-0.148352,47.0,1.948368557549045,8.832223314837117,4.011170470770269e-10,0.35156341662630675,253.6783003193357,15.216180847325322,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-310/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,310.0,276.4,1.941344,1.957,0.992,12.0,8.84,45.13,8.34,37.19,0.0053924,-0.1665297,47.0,1.965229923663429,8.842095666741834,9.360240953482223e-10,0.2597179049291646,1095.550407088823,6.780284405663696,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-315/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,315.0,290.4,1.65,,,60.0,10.05,40.3,9.52,33.1,0.0042813,-0.10836669999999998,47.4,1.493195294435058,10.055590710297437,1.8951901539217133e-11,0.2748808913970665,494.1327419526626,6.306311794524908,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-315/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,315.0,282.7,1.941344,1.957,0.992,12.0,8.91,46.45,8.32,37.86,0.0049896,-0.14864000000000002,47.0,1.952099795809525,8.920709207631115,4.058152271211337e-10,0.339459099098541,282.4280779833105,15.223339728428584,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXP6-72-315/P,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,315.0,281.0,1.941344,1.957,0.992,12.0,8.95,45.22,8.45,37.28,0.0054595,-0.1668618,47.0,1.9688391707995652,8.951709962078658,9.450376701518977e-10,0.2549814992463245,1334.5835004964076,6.7537064264034035,-0.476,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-320/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,320.0,295.1,1.65,,,60.0,10.15,40.5,9.61,33.3,0.0043239,-0.1089045,47.4,1.5017732575040892,10.156051498164425,1.9532926194047568e-11,0.26922582061330996,451.56456305627324,6.483762994518514,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-320/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,320.0,287.3,1.941344,1.957,0.992,12.0,8.99,46.54,8.43,37.96,0.0050344000000000005,-0.148928,47.0,1.9522985021926114,8.997685902027333,3.9389659966353375e-10,0.33389805370233744,390.5519549392674,14.846995756866171,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-325/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,325.0,299.8,1.65,,,60.0,10.25,40.7,9.71,33.5,0.004366500000000001,-0.10944229999999999,47.4,1.5096107726635846,10.255620677606691,1.9885060998629285e-11,0.2637129102888796,480.9130795169061,6.5513620452992365,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-325/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,325.0,291.9,1.941344,1.957,0.992,12.0,9.09,46.63,8.54,38.06,0.0050904,-0.14921600000000002,47.0,1.9548820877665782,9.09634426977048,3.933916551093638e-10,0.32743265431821245,469.14201267735234,14.725296705928224,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-60-330/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,330.0,304.6,1.65,,,60.0,10.35,40.9,9.8,33.7,0.0044091,-0.10998009999999998,47.4,1.518186233284792,10.356061985821817,2.048217826004234e-11,0.258271949427195,440.96353878785567,6.725525322830679,-0.3559,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-330/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,330.0,296.5,1.941344,1.957,0.992,12.0,9.19,46.72,8.65,38.15,0.0051464,-0.149504,47.0,1.9572185949371546,9.19503706661963,3.9166321162042795e-10,0.3224739199479469,588.345614483709,14.57598256242366,-0.453,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-340/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,340.0,316.4,1.94,,,72.0,9.42,46.3,8.92,38.12,0.004201320000000001,-0.12227829999999999,44.8,1.7032379096874577,9.425827648267353,1.4609412475103643e-11,0.3286382484423486,531.2215495588533,6.526001810459024,-0.3473,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM6-72-345/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,345.0,321.2,1.94,,,72.0,9.51,46.5,9.0,38.34,0.00424146,-0.12280650000000001,44.8,1.7123081116867485,9.516291247329406,1.5143033020658133e-11,0.319837795729165,483.474468836858,6.757230248792326,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-350/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,350.0,325.9,1.94,,,72.0,9.61,46.65,9.1,38.46,0.0042860599999999995,-0.12320265,44.8,1.7172712561244199,9.615899664344004,1.5177892018124265e-11,0.318022210043525,518.0283523164426,6.683960994932141,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH120-350/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,350.0,326.6,1.8,,,60.0,11.04,40.2,10.48,33.4,0.00525504,-0.1056054,45.6,2.0140779537431475,11.040061527612233,7.13070340386032e-13,3.1751741165966223,981421.0938300953,98.05799610214105,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-355/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,355.0,328.1,1.97,,,72.0,9.66,47.6,9.13,38.9,0.0041151600000000005,-0.1296148,45.5,1.789582000771376,9.666673987696031,2.6888644154883908e-11,0.35566287626032916,514.7901999979584,8.3346448277541,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH120-355/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,355.0,331.3,1.8,,,60.0,11.14,40.4,10.57,33.6,0.005302640000000001,-0.10613079999999998,45.6,1.473281921991184,11.145387633112634,1.362471094732904e-11,0.20981556708502197,433.8352972095964,5.008578423496884,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-360/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,360.0,332.8,1.97,,,72.0,9.8,47.7,9.21,39.1,0.0041748,-0.1298871,45.5,1.8010654433142907,9.811483287254077,3.036127211794501e-11,0.33632597317346286,287.0253375876388,9.301672913023559,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH120-360/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,360.0,336.1,1.8,,,60.0,11.24,40.6,10.66,33.8,0.00535024,-0.1066562,45.6,1.4816311464731258,11.245759911271026,1.4009413512411609e-11,0.20532944544121465,400.6837743157577,5.172555015029031,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-365/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,365.0,337.6,1.97,,,72.0,9.84,48.0,9.29,39.3,0.00419184,-0.130704,45.5,1.8072959339139587,9.847697631721802,2.8447598573664384e-11,0.34296835665134806,438.4216885836046,8.67238363756129,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH120-365/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,365.0,340.9,1.8,,,60.0,11.33,40.8,10.74,34.0,0.005393080000000001,-0.10718159999999999,45.6,1.4900134809289745,11.336148031356695,1.4396076855716024e-11,0.20109307987581124,370.5876697902402,5.339875345190043,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-370/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,370.0,342.3,1.97,,,72.0,9.91,48.2,9.37,39.5,0.00422166,-0.1312486,45.5,1.8143911635414307,9.916434083105143,2.8515163914706747e-11,0.33753644746751665,519.8854628290582,8.624924253842122,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH120-370/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,370.0,345.7,1.8,,,60.0,11.42,41.0,10.82,34.2,0.00543592,-0.107707,45.6,1.498395366915929,11.426518712918089,1.4789209792441286e-11,0.1969197696451449,344.97972458377575,5.505503606241051,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-375/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,375.0,347.1,1.97,,,72.0,9.98,48.4,9.45,39.7,0.00425148,-0.1317932,45.5,1.82149602718515,9.98520485123189,2.8586131964346294e-11,0.33219320224528487,636.9611934842611,8.578985691320383,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH120-375/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,375.0,350.5,1.8,,,60.0,11.51,41.2,10.91,34.4,0.00547876,-0.1082324,45.6,1.5061200464221607,11.51617749277998,1.5024945715303958e-11,0.19287948793638807,359.37604516910204,5.572316050950646,-0.3335,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-380/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,380.0,351.8,1.97,,,72.0,10.03,48.6,9.53,39.9,0.00427278,-0.1323378,45.5,1.8268764197001428,10.032306670399006,2.795625928576173e-11,0.32766455896759955,1424.7704087865204,8.32531644313453,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-385/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,385.0,356.6,1.97,,,72.0,10.09,48.8,9.61,40.1,0.00429834,-0.13288239999999998,45.5,1.8331482169384166,10.09032861195168,2.7694690497994672e-11,0.3228409906324884,9912.807325951293,8.180747426191019,-0.3698,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-385/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,385.0,357.3,2.0,,,72.0,10.05,48.5,9.56,40.3,0.004482300000000001,-0.1280885,46.2,1.7885748483831774,10.05260375619643,1.6739867183449724e-11,0.2785127843269755,1075.0060064735244,7.128212908415851,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-385/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,385.0,361.3,2.01,,,72.0,10.08,48.4,9.56,40.3,0.0063504,-0.12351679999999998,45.4,1.7413648099005292,10.08567168315182,8.48318785255874e-12,0.27801715659005743,494.10604908762355,4.665168498785434,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-390/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,390.0,361.3,1.97,,,72.0,10.16,49.0,9.68,40.3,0.00432816,-0.133427,45.5,1.841191507069985,10.16010216291254,2.8110291889096206e-11,0.31769401443632905,31594.378834557683,8.249376873165952,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-390/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,390.0,362.0,2.0,,,72.0,10.14,48.7,9.63,40.5,0.00452244,-0.1286167,46.2,1.7980801643552033,10.143788631270047,1.7406565212065456e-11,0.2730119519103366,730.6969162476959,7.397885099568121,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-390/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,390.0,364.0,2.0,,,72.0,10.1,48.7,9.61,40.6,0.0036057,-0.1287628,44.8,1.7720430501064244,10.100005755486873,1.1718216160952503e-11,0.26834256719929944,470903.6682321843,4.013686668086417,-0.3454,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-390/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,390.0,366.1,2.01,,,72.0,10.15,48.6,9.63,40.5,0.006394500000000001,-0.1240272,45.4,1.7489682663429285,10.155405140867822,8.600730392865326e-12,0.27329131202749396,513.1978799548455,4.72254176580674,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SH108-390/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,390.0,359.3,1.94,,,54.0,13.56,36.7,12.79,30.5,0.00736308,-0.10918250000000002,45.37,1.4642276408412627,13.567627710675092,1.7471614057812704e-10,0.13739320176869668,244.24784909623122,11.993539884020604,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-390/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,390.0,368.3,1.94,,,54.0,13.54,36.7,12.79,30.5,0.005689508,-0.09286935000000002,42.9,1.3136460236393546,13.552071767969094,9.82725851667713e-12,0.16336356980454228,183.23270864004417,4.600822710213168,-0.32263,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-395/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,395.0,366.1,1.97,,,72.0,10.22,49.2,9.76,40.5,0.00435372,-0.1339716,45.5,1.8510518109525091,10.22000459033961,2.92499628266456e-11,0.3123030263911967,695336.4956415504,8.545400984834716,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-395/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,395.0,366.8,2.0,,,72.0,10.23,48.9,9.71,40.7,0.00456258,-0.1291449,46.2,1.8066982049887215,10.234208767848212,1.78756279173427e-11,0.2676881673279983,650.6536052402055,7.555422356721696,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-395/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,395.0,368.8,2.0,,,72.0,10.16,48.9,9.69,40.8,0.0036271200000000006,-0.1292916,44.8,1.7845175575206307,10.161233308662064,1.2743370462184412e-11,0.26277225722213904,2164.718623211411,4.68175733376031,-0.3454,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-395/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,395.0,370.9,2.01,,,72.0,10.23,48.8,9.71,40.7,0.0064449,-0.12453759999999998,45.4,1.756529696592482,10.235113215027557,8.722218181917613e-12,0.2683754246741113,536.9382271556557,4.774036709496758,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-395/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,395.0,373.1,1.94,,,54.0,13.62,36.9,12.87,30.7,0.005723124,-0.09337545,42.9,1.321306116875162,13.631654084278635,9.993637081345481e-12,0.16029792497612314,187.3384208748224,4.692800848380739,-0.32263,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-72-400/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,400.0,370.9,1.97,,,72.0,10.28,49.4,9.83,40.7,0.00437928,-0.1345162,45.5,1.8602947904920137,10.280004575794715,3.015297985521386e-11,0.30724760820991803,690283.5906995927,8.760929049217209,-0.3698,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-LDD72-400/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,400.0,371.6,2.0,,,72.0,10.31,49.1,9.78,40.9,0.004598260000000001,-0.1296731,46.2,1.815359527850951,10.314646689171374,1.834582066780631e-11,0.26270184660786955,582.8786853360497,7.717023333622741,-0.3473,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-400/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,400.0,373.6,2.0,,,72.0,10.22,49.1,9.76,41.0,0.003648540000000001,-0.12982040000000003,44.8,1.7914321242955982,10.220377559637715,1.2762086838881879e-11,0.2585307677207794,6998.059324140701,4.63858159599157,-0.3454,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-400/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,400.0,375.7,2.01,,,72.0,10.29,49.0,9.78,40.9,0.006482699999999999,-0.125048,45.4,1.7633394249843333,10.294175903096278,8.732706156590185e-12,0.2641297300135595,650.8520144041472,4.728889596230114,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SH108-400/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,400.0,368.8,1.94,,,54.0,13.7,37.1,12.95,30.9,0.007439099999999999,-0.1103725,45.37,1.480294688867116,13.705743463998656,1.7725662020202566e-10,0.13160420151602864,313.9181674412768,12.023035173395055,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-400/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,400.0,378.0,1.94,,,54.0,13.7,37.1,12.95,30.9,0.00575674,-0.09388155,42.9,1.328965428618762,13.711246577432293,1.0161040342973042e-11,0.15727080463913595,191.57917549216322,4.783646797440653,-0.32263,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-405/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,405.0,378.4,2.0,,,72.0,10.28,49.3,9.84,41.2,0.0036699600000000003,-0.1303492,44.8,1.8001970761851038,10.280003949846535,1.3135572478208336e-11,0.2538891786847875,660787.4637253932,4.831401984676114,-0.3454,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-405/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,405.0,380.5,2.01,,,72.0,10.35,49.2,9.86,41.1,0.006520499999999999,-0.12555840000000001,45.4,1.7640697440082784,10.350005661103342,7.988032332702871e-12,0.26111481084457955,477389.64660180284,3.8927603301620435,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SH108-405/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,405.0,373.5,1.94,,,54.0,13.77,37.3,13.03,31.1,0.0074771099999999995,-0.1109675,45.37,1.4883266455972926,13.774858282217933,1.7852278760185006e-10,0.12876427701722212,364.96114223748964,12.037274463906064,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-405/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,405.0,382.8,1.94,,,54.0,13.78,37.3,13.03,31.1,0.005790356000000001,-0.09438765,42.9,1.3366239742717894,13.790849051363159,1.0329458701026369e-11,0.15428148615995124,195.96173124329607,4.873380871257221,-0.32263,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-405/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,405.0,384.5,1.94,,,54.0,13.9,37.4,13.11,30.9,0.00574487,-0.0894608,43.3,1.2826606259498021,13.917550529314614,2.9675250898144307e-12,0.18709151632116586,148.17627623277681,0.12909255923582091,-0.29154,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-410/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,410.0,383.2,2.0,,,72.0,10.34,49.5,9.91,41.4,0.0036913800000000006,-0.13087800000000002,44.8,1.8090661541790567,10.340003927441535,1.3529204082283594e-11,0.24937220574722588,656543.6164272038,5.033148174963433,-0.3454,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-410/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,410.0,385.3,2.01,,,72.0,10.41,49.4,9.93,41.3,0.0065582999999999995,-0.12606879999999998,45.4,1.772644914078972,10.410005789272548,8.213810083118506e-12,0.2566201517001091,461221.7339273929,4.080999332616976,-0.3083,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SH108-410/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,410.0,378.3,1.94,,,54.0,13.84,37.5,13.1,31.3,0.00751512,-0.1115625,45.37,1.4969436300951489,13.844611455842742,1.8139524561662978e-10,0.1258810638243036,377.79642901378406,12.134918135103467,-0.4016,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-410/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,410.0,387.6,1.94,,,54.0,13.86,37.5,13.1,31.3,0.005823972,-0.09489375,42.9,1.344761487677513,13.871182166237146,1.059441490667157e-11,0.1512917501905,187.52213308478937,5.04304943241471,-0.32263,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-410/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,410.0,389.3,1.94,,,54.0,13.97,37.6,13.19,31.1,0.005773801,-0.0899392,43.3,1.2895922070864227,13.986192142179977,2.9907433819533062e-12,0.18414748983011772,158.87585517889676,0.147775588122432,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-415/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,415.0,392.5,1.94,,,54.0,13.94,37.7,13.18,31.5,0.005857588,-0.09539985000000001,42.9,1.3392608741777396,13.94000417188415,8.297240398259421e-12,0.15043841904250502,502681.11005050794,2.8661550214359965,-0.32263,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-415/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,415.0,394.2,1.94,,,54.0,14.04,37.8,13.26,31.3,0.005802732,-0.0904176,43.3,1.2969571175547374,14.05575217072859,3.0408042943750545e-12,0.1812362191517288,161.53688055524648,0.24313135165044666,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,420.0,390.9,2.15,,,72.0,11.04,49.1,10.45,40.2,0.00660192,-0.1285929,46.8,1.7862185814478435,11.04777888760494,1.262075364393253e-11,0.3253807295919181,461.78880185160074,4.591309908817196,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-420/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,420.0,391.9,2.15,,,72.0,11.04,49.1,10.45,40.2,0.00484656,-0.1272181,45.7,1.7669227313663183,11.048338516596193,9.34306858273053e-12,0.3294376431043958,436.1676156869479,3.3875514450350677,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-420/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,420.0,392.0,2.15,,,72.0,11.16,49.3,10.27,40.9,0.00639468,-0.12926459999999998,46.3,1.8146015458428546,11.19068060845588,1.6961960668347223e-11,0.26583214025280183,96.69582323491315,7.081325792830044,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD108-420/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,420.0,397.3,1.94,,,54.0,14.02,37.9,13.25,31.7,0.005891204,-0.09590595,42.9,1.360556718677455,14.031097604504652,1.10368989007705e-11,0.14544954457077353,183.75160342191427,5.296850155491762,-0.32263,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-420/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,420.0,399.0,1.94,,,54.0,14.11,38.0,13.34,31.5,0.005831663,-0.090896,43.3,1.303886142580696,14.124459196663903,3.0639422865903147e-12,0.1783621611262194,174.0546400868506,0.2605200883789617,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-425/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,425.0,395.7,2.15,,,72.0,11.11,49.3,10.52,40.4,0.006643779999999999,-0.1291167,46.8,1.7940076659055357,11.117445552358475,1.2805222970125893e-11,0.32068239949774335,478.51137503160794,4.660117830252568,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-425/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,425.0,396.7,2.15,,,72.0,11.11,49.3,10.52,40.4,0.004877289999999999,-0.1277363,45.7,1.7746190521706322,11.117998847763046,9.479167300714959e-12,0.32473412557861603,451.03948353018706,3.4550207296165842,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-425/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,425.0,396.8,2.15,,,72.0,11.23,49.5,10.35,41.1,0.00643479,-0.129789,46.3,1.8213712887282871,11.259265312128942,1.6947224278953602e-11,0.26160276944904426,100.38502561680986,7.013611611209954,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-425/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,425.0,403.9,1.94,,,54.0,14.18,38.2,13.41,31.7,0.005860594,-0.09137440000000001,43.3,1.7375581561214457,14.180001734777779,4.015732475791473e-09,0.10723894826255227,879415.1056569205,79.28074155553767,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-430/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,430.0,400.4,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00669162,-0.12964050000000002,46.8,1.7912674015090457,11.190019968805931,1.115573224285382e-11,0.3177194711483144,178042.36079970284,3.397934512687735,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-430/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,430.0,401.5,2.15,,,72.0,11.19,49.5,10.6,40.6,0.00491241,-0.1282545,45.7,1.7822749127684092,11.197622941581903,9.619271457369746e-12,0.3198069719849507,469.4565749366308,3.5168948825623616,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-430/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,430.0,401.6,2.15,,,72.0,11.3,49.7,10.42,41.3,0.0064749,-0.1303134,46.3,1.8290269730878088,11.328637809209688,1.7137513071302278e-11,0.2573335316792006,101.53950301965845,7.054998354705604,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-430/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,430.0,402.8,2.15,,,72.0,11.07,49.7,10.42,41.3,0.00530253,-0.1306116,44.8,1.813373584517336,11.081882583747833,1.3605197472569018e-11,0.2640314344374926,245.97579557918377,5.040507409820009,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-430/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,430.0,408.7,1.94,,,54.0,14.25,38.4,13.48,31.9,0.0058895250000000005,-0.0918528,43.3,1.3186099382424468,14.263653541687654,3.164865050789058e-12,0.17269862384831874,180.24300298660955,0.4459833330805341,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-435/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,435.0,405.2,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00673348,-0.13016430000000004,46.8,1.8095453295740247,11.26675794721296,1.318224748292521e-11,0.3111958036334772,518.5102338106456,4.791081117467032,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-435/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,435.0,406.3,2.15,,,72.0,11.26,49.7,10.67,40.8,0.00494314,-0.12877270000000002,45.7,1.789972206459299,11.267298430122242,9.75734480831969e-12,0.3152333088639414,486.3411758535138,3.5834125788860685,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-435/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,435.0,406.4,2.15,,,72.0,11.37,49.9,10.49,41.5,0.006515009999999999,-0.1308378,46.3,1.836683830740174,11.39802092787088,1.7328812631272668e-11,0.2531212238244035,102.70853037748823,7.096185892704443,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-435/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,435.0,407.6,2.15,,,72.0,11.14,49.9,10.49,41.5,0.00533606,-0.13113719999999998,44.8,1.821075921143264,11.151523355360654,1.378021274924708e-11,0.259760000935365,251.11838812093012,5.094521114255081,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-435/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,435.0,409.2,2.14,,,60.0,13.55,40.9,12.8,34.0,0.0057262300000000006,-0.10761199,43.4,1.490181269185477,13.56101198166257,1.6085416195825807e-11,0.17653586009255146,217.22347454612182,4.682140403580438,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-435/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,435.0,408.9,2.14,,,60.0,13.55,40.9,12.8,34.0,0.006329205000000001,-0.13553851,42.8,1.5406723399035442,13.559203424177396,3.960483827472173e-11,0.1678159199089908,247.0717098282525,-10.771693489548833,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-435/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,435.0,413.6,1.94,,,54.0,14.32,38.6,13.56,32.1,0.005918456,-0.0923312,43.3,1.325534993568157,14.33244654296943,3.1878856089593503e-12,0.1699240981958497,195.50111991270035,0.4613134030335071,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-440/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,440.0,410.0,2.15,,,72.0,11.33,49.9,10.74,41.0,0.0067753399999999995,-0.1306881,46.8,1.8173355126096282,11.336446844873537,1.3370664650131784e-11,0.30668708878346684,538.9868728218673,4.85837221418425,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-440/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,440.0,411.1,2.15,,,72.0,11.33,49.9,10.74,41.0,0.00497387,-0.1292909,45.7,1.7976698099741357,11.336980980561282,9.89637143342542e-12,0.31071959460617027,504.29205558800237,3.649427556698969,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-440/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,440.0,411.2,2.15,,,72.0,11.44,50.1,10.56,41.7,0.006555119999999999,-0.13136219999999998,46.3,1.8443418349508054,11.467414484979983,1.7521117146255177e-11,0.24896471707605097,103.89239002564727,7.13717366972804,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-440/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,440.0,412.4,2.15,,,72.0,11.21,50.1,10.56,41.7,0.00536959,-0.1316628,44.8,1.828778757873188,11.221171592450473,1.395624478277717e-11,0.255545357022907,256.4243374466113,5.148154163217611,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-440/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,440.0,414.0,2.14,,,60.0,13.62,41.1,12.87,34.2,0.005755811999999999,-0.10813821000000001,43.4,1.4979933036017685,13.630657661926191,1.632903927657956e-11,0.17349547515060448,221.7192102822984,4.765285837795343,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-440/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,440.0,413.8,2.14,,,60.0,13.62,41.1,12.87,34.2,0.006361902,-0.13620129000000003,42.8,1.5487915670276997,13.628874828926191,4.0221267863034355e-11,0.16476451342447643,252.86039029213143,-10.698179450945144,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-440/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,440.0,418.5,1.94,,,54.0,14.39,38.8,13.63,32.3,0.005947387,-0.09280959999999999,43.3,1.3328940126028632,14.40207887917206,3.2387340052870236e-12,0.1671686649764379,199.15399914344897,0.5515341587700604,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-445/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,445.0,414.8,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0068172,-0.13121190000000002,46.8,1.8251259568583593,11.406142688971055,1.3560366447230991e-11,0.30223709535016086,560.9111817088215,4.925155004544134,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-445/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,445.0,415.9,2.15,,,72.0,11.4,50.1,10.81,41.2,0.0050046000000000005,-0.1298091,45.7,1.7951160234162518,11.400007192237391,8.632779720938824e-12,0.30815851925527477,488447.83020992915,2.419494898633385,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-445/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,445.0,416.0,2.15,,,72.0,11.51,50.3,10.63,41.9,0.00659523,-0.1318866,46.3,1.852000959576997,11.53681830169174,1.7714420924512947e-11,0.24486291219495473,105.09137097284423,7.17796136630687,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-445/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,445.0,417.2,2.15,,,72.0,11.28,50.3,10.63,41.9,0.00540312,-0.13218839999999998,44.8,1.836482613612758,11.290827063890001,1.4133401975824477e-11,0.25138626351294563,261.90267846217597,5.201484289780118,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-445/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,445.0,418.9,2.14,,,60.0,13.69,41.3,12.94,34.4,0.005785393999999999,-0.10866442999999999,43.4,1.5058045635362223,13.700311249742894,1.6573985760721045e-11,0.17048858856960689,226.35362830696084,4.847506322828313,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-445/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,445.0,418.6,2.14,,,60.0,13.69,41.3,12.94,34.4,0.006394599,-0.13686407,42.8,1.556909968713486,13.69855408317714,4.0841260539778714e-11,0.16174675155695423,258.8603613327452,-10.62550677450922,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-445/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,445.0,423.3,1.94,,,54.0,14.46,39.0,13.7,32.5,0.005976318,-0.093288,43.3,1.340252148658833,14.471718957847239,3.2898591660657496e-12,0.1644420031717486,202.9046783425395,0.6406723879956421,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-450/M {Blk},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,450.0,419.6,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00685308,-0.1317357,46.8,1.8329579778918992,11.465886206252307,1.3747099710482085e-11,0.2981033228364801,580.3847124127503,4.9964478034051245,-0.3265,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NH144-450/M {Wht},ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,450.0,420.7,2.15,,,72.0,11.46,50.3,10.87,41.4,0.00503094,-0.1303273,45.7,1.8031391296985968,11.46001282194526,8.794033877456291e-12,0.30396324043616585,271677.3853751143,2.5303995683389298,-0.3317,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-450/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,450.0,420.8,2.15,,,72.0,11.58,50.5,10.69,42.1,0.00663534,-0.132411,46.3,1.8605321991952943,11.606937954377779,1.8117797118567855e-11,0.24070192354556758,103.47215835629524,7.323656523114963,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHLDD144-450/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,450.0,422.0,2.15,,,72.0,11.34,50.5,10.69,42.1,0.00543186,-0.132714,44.8,1.8442342744935778,11.350521586443012,1.4308111245841457e-11,0.2474947907886425,266.74594866057487,5.260147455309951,-0.3307,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-450/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,450.0,423.7,2.14,,,60.0,13.76,41.5,13.01,34.6,0.0058149759999999995,-0.10919065000000001,43.4,1.5136150624467437,13.769972610239108,1.6820244108678012e-11,0.167514648665998,231.13322636076862,4.928817168705238,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-450/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,450.0,423.4,2.14,,,60.0,13.76,41.5,13.01,34.6,0.006427296,-0.13752685,42.8,1.565027483510653,13.768241053890947,4.146474848219156e-11,0.15876204632309981,265.0833008040007,-10.553586417827331,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD108-450/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,450.0,428.2,1.94,,,54.0,14.53,39.2,13.78,32.7,0.006005248999999999,-0.0937664,43.3,1.3471734530960429,14.540593364981735,3.3127540378887053e-12,0.16176206062673873,221.87489920840807,0.6540860555470303,-0.29154,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM6-NHDB144-455/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,455.0,425.6,2.15,,,72.0,11.65,50.7,10.76,42.3,0.00667545,-0.1329354,46.3,1.8148911902538436,11.650006261064165,8.59137958512872e-12,0.24711310963226832,459807.2802755418,0.7973040080929691,-0.3209,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-455/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,455.0,428.5,2.14,,,60.0,13.83,41.7,13.08,34.8,0.005844558,-0.10971687000000001,43.4,1.5214248132183916,13.839641611378084,1.706780281005331e-11,0.16457311583756698,236.06491886324815,5.009233395157931,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-455/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,455.0,428.2,2.14,,,60.0,13.83,41.7,13.08,34.8,0.006459993000000001,-0.13818963,42.8,1.5731442014915915,13.837935609581269,4.209173983703936e-11,0.1558098895724733,271.54193814831194,-10.482480570437374,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-460/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,460.0,433.3,2.14,,,60.0,13.9,41.9,13.15,35.0,0.005874140000000001,-0.11024309,43.4,1.5292338287393645,13.909318124351262,1.7316650550543424e-11,0.16166346211292046,241.1560580279332,5.088769904490313,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-460/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,460.0,433.0,2.14,,,60.0,13.9,41.9,13.15,35.0,0.006492690000000001,-0.13885241,42.8,1.5812601119645568,13.907637622819689,4.2722192969385724e-11,0.15288973994732694,278.24985200230196,-10.412151456175616,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-465/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,465.0,438.2,2.14,,,60.0,13.97,42.1,13.22,35.2,0.005903722000000001,-0.11076931000000001,43.4,1.5370421213946435,13.979002022878753,1.7566776046510938e-11,0.15878517106988832,246.4144874617316,5.167441032133014,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-465/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,465.0,437.9,2.14,,,60.0,13.97,42.1,13.22,35.2,0.006525387000000001,-0.13951519,42.8,1.589375227871408,13.977346968789734,4.335607846877518e-11,0.1500010780960715,285.22172263315554,-10.342585077813713,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB120-470/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,470.0,443.0,2.14,,,60.0,14.04,42.3,13.28,35.4,0.0059333039999999995,-0.11129553,43.4,1.5454058188863438,14.049357847595859,1.7978732368216536e-11,0.15588223625604364,233.87740824826636,5.325303536415035,-0.3359,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD120-470/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,470.0,442.7,2.14,,,60.0,14.04,42.3,13.28,35.4,0.0065580840000000005,-0.14017797,42.8,1.5981053587265226,14.047690452338667,4.440525074008687e-11,0.14706983461126133,268.49662777209033,-10.203575719295506,-0.3511,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-520/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,520.0,486.7,2.56,,,72.0,13.53,49.0,12.79,40.7,0.0059532,-0.118286,45.84,1.7462563589841997,13.54160083361372,8.694155949495618e-12,0.22143938147310896,258.26375429687414,8.565436880412744,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-520/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,520.0,485.4,2.56,,,72.0,13.53,49.0,12.79,40.7,0.00857802,-0.12887,46.08,1.8078030954837951,13.539686889547593,2.263624822593119e-11,0.21072727589752333,294.3297799018282,7.393827039294511,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-525/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,525.0,491.5,2.56,,,72.0,13.59,49.2,12.85,40.9,0.005979599999999999,-0.11876880000000001,45.84,1.7145289226370168,13.602576390443899,4.619933196014363e-12,0.22525277540592395,243.40729854105166,3.043742714820175,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-525/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,525.0,490.2,2.56,,,72.0,13.59,49.2,12.85,40.9,0.00861606,-0.129396,46.08,1.7840359541507753,13.600353355333086,1.4156601833999602e-11,0.21311462700878073,279.73808528652495,3.3252816902261175,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-530/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,530.0,496.3,2.56,,,72.0,13.65,49.4,12.91,41.1,0.006006,-0.1192516,45.84,1.7615037898086636,13.660993575081516,8.914922631050859e-12,0.21530738881063527,267.3330419180575,8.708043673062718,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-530/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,530.0,495.0,2.56,,,72.0,13.65,49.4,12.91,41.1,0.0086541,-0.129922,46.08,1.8236369048104526,13.659124242586882,2.321540101860141e-11,0.20458200273938154,306.0576958891985,7.536125237866576,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-535/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,535.0,501.1,2.56,,,72.0,13.71,49.6,12.96,41.3,0.006032399999999999,-0.11973440000000002,45.84,1.7697535652342493,13.721457500828324,9.107932581062545e-12,0.21224505209899505,253.97157795492197,8.862287962876529,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-535/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,535.0,499.8,2.56,,,72.0,13.71,49.6,12.96,41.3,0.00869214,-0.130448,46.08,1.8322271672958592,13.719572349897875,2.3720960967767536e-11,0.2014948275995258,288.5910046772495,7.688903990125561,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-540/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,540.0,505.9,2.56,,,72.0,13.77,49.8,13.02,41.5,0.006058799999999999,-0.1202172,45.84,1.7773760135570378,13.781156398124594,9.220236719014613e-12,0.2092484072237751,258.2688915327224,8.931653280901935,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-540/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,540.0,504.6,2.56,,,72.0,13.77,49.8,13.02,41.5,0.008730179999999999,-0.130974,46.08,1.8401424906308603,13.779293431888075,2.401555587747132e-11,0.19849183602445317,294.10368947190904,7.758098569618805,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-540/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,540.0,511.9,2.56,,,72.0,13.87,49.9,13.11,41.2,0.005348271999999999,-0.12106238999999999,43.2,1.7274148462951182,13.884349256819162,3.8948938998214994e-12,0.24940977534952585,241.07984056051427,1.0029582180870427,-0.30236,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-545/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,545.0,510.7,2.56,,,72.0,13.83,50.0,13.07,41.7,0.0060852,-0.1207,45.84,1.7856270181716236,13.841597217384084,9.417168281090002e-12,0.20623499946794324,245.94089747265346,9.083940628232718,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-545/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,545.0,512.3,2.57,,,72.0,13.83,50.0,13.07,41.7,0.006915000000000001,-0.1305,44.1,1.8321639171987747,13.84019694564569,1.9200537273053376e-11,0.19827125951664587,268.91303010168855,6.777983886930506,-0.333,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-545/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,545.0,516.8,2.56,,,72.0,13.93,50.1,13.17,41.4,0.005371408,-0.12154761,43.2,1.7348386032929928,13.944010367302349,3.945297181956811e-12,0.2463122913691526,244.89937708133914,1.073313411775986,-0.30236,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-550/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,550.0,515.6,2.56,,,72.0,13.89,50.2,13.13,41.9,0.006111599999999999,-0.12118280000000001,45.84,1.7932485065875219,13.901295983953075,9.5311226804232e-12,0.20329173349191756,249.97576125144317,9.15173694717144,-0.3197,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-550/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,550.0,514.2,2.56,,,72.0,13.89,50.2,13.13,41.9,0.00880626,-0.132026,46.08,1.8566478475098143,13.899439120741961,2.483023477960462e-11,0.1925045747765672,283.277292387875,7.976510700926599,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-550/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,550.0,521.6,2.56,,,72.0,13.99,50.3,13.23,41.6,0.005394543999999999,-0.12203283,43.2,1.7422617883302005,14.003677231935294,3.995950277270945e-12,0.243243398878557,248.8058389536928,1.1430290404915378,-0.30236,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-555/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,555.0,520.4,2.56,,,72.0,13.95,50.4,13.19,42.1,0.006137999999999999,-0.1216656,45.84,1.8008694192943069,13.96100022799775,9.645562281861953e-12,0.20037569130674232,254.1075428536294,9.218924333449639,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHLDD144-555/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,555.0,519.0,2.56,,,72.0,13.95,50.4,13.19,42.1,0.0088443,-0.132552,46.08,1.8645612977062795,13.959165423332351,2.5130411753501964e-11,0.18958250657856465,288.5492472626753,8.043506373010707,-0.3287,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-555/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,555.0,526.4,2.56,,,72.0,14.05,50.5,13.28,41.8,0.00541768,-0.12251805,43.2,1.7502743759198893,14.064221325341302,4.082824770351374e-12,0.24019476092136313,237.30111808830353,1.2893636176072911,-0.30236,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-560/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,560.0,525.2,2.56,,,72.0,14.01,50.6,13.24,42.3,0.0061644,-0.1221484,45.84,1.80912124472986,14.02141306333,9.847566934409335e-12,0.1974347874634559,242.35924301461935,9.368388239571942,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-560/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,560.0,531.3,2.56,,,72.0,14.11,50.7,13.34,42.0,0.005440815999999999,-0.12300327,43.2,1.7576966737217599,14.123887687949692,4.1342789676997905e-12,0.23717951993316266,240.97625494316415,1.3575609232697443,-0.30236,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-SHDB144-565/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,565.0,530.0,2.56,,,72.0,14.07,50.8,13.3,42.5,0.006190800000000001,-0.12263120000000001,45.84,1.8167412509739183,14.081117309257213,9.963635947661874e-12,0.19457004918447832,246.2466917741294,9.434068960833795,-0.3197,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-565/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,565.0,536.1,2.56,,,72.0,14.17,50.9,13.39,42.2,0.005463951999999999,-0.12348848999999999,43.2,1.765710594492299,14.18440799978571,4.222974591367365e-12,0.2341785659496303,230.31026789651426,1.5020835448963588,-0.30236,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-570/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,570.0,542.9,2.56,,,72.0,14.23,51.1,13.45,42.4,0.005400285,-0.11775484,43.3,1.7216646562106872,14.245924435316285,1.8040644346345539e-12,0.23991318034932482,214.38528219234806,-0.39963590511931546,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-575/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,575.0,547.8,2.56,,,72.0,14.29,51.3,13.5,42.6,0.0054230549999999995,-0.11821572000000001,43.3,1.7294130323205932,14.306435101975971,1.8421456373987084e-12,0.23697759989619144,206.04739233084342,-0.2584059343887411,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-575/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,575.0,541.8,2.81,,,60.0,18.13,40.5,17.17,33.5,0.008996105999999999,-0.10502865000000002,43.2,1.4737290737098172,18.141711043914412,2.0856871221476575e-11,0.14147444065521567,219.01818909997237,5.832593900044079,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-580/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,580.0,552.6,2.56,,,72.0,14.35,51.5,13.56,42.8,0.005445825,-0.11867660000000001,43.3,1.7366029846324638,14.366083211373697,1.8644744274319354e-12,0.23407036373395892,208.84571094906605,-0.1938739097947544,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-580/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,580.0,546.6,2.81,,,60.0,18.17,40.7,17.22,33.7,0.009015954000000001,-0.10554731,43.2,1.4812757869702207,18.180667985162582,2.102271336996493e-11,0.13957295702043276,237.72442623578291,5.87920822799926,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-585/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,585.0,557.5,2.56,,,72.0,14.41,51.7,13.61,43.0,0.005468595,-0.11913748,43.3,1.7443525266169309,14.426571405798263,1.903322230282052e-12,0.23117998360249709,201.02721194173444,-0.05436812983592316,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-585/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,585.0,551.4,2.81,,,60.0,18.21,40.9,17.26,33.9,0.009035802,-0.10606597,43.2,1.489222345718886,18.220454700735896,2.1331018137136553e-11,0.13766724839198746,239.7888451432896,5.985664594268499,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-590/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,590.0,562.4,2.56,,,72.0,14.46,51.9,13.66,43.2,0.00548757,-0.11959836,43.3,1.7515727498038465,14.47625394424232,1.9255692981525012e-12,0.22847957782230946,203.26233655947246,0.012946544547060247,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-590/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,590.0,556.2,2.81,,,60.0,18.25,41.1,17.31,34.1,0.00905565,-0.10658463000000001,43.2,1.4967625542107041,18.259458888941065,2.149478868016954e-11,0.13578881961864953,261.9912335514705,6.0300827583092955,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-595/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,595.0,567.2,2.56,,,72.0,14.51,52.1,13.71,43.4,0.005506545,-0.12005924000000001,43.3,1.7587922321059606,14.525940979750272,1.9478993185547042e-12,0.22579934651298864,205.52993425720643,0.07964207961795049,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-595/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,595.0,561.1,2.81,,,60.0,18.29,41.3,17.35,34.3,0.009075498,-0.10710328999999999,43.2,1.5047051948154289,18.299263914755212,2.1803518262081424e-11,0.13390319458317762,264.3687379738761,6.134181646879661,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-600/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,600.0,572.1,2.56,,,72.0,14.56,52.3,13.77,43.6,0.00552552,-0.12052012000000001,43.3,1.7654489445116832,14.57483070683564,1.953474469784327e-12,0.22315474647394995,219.08147378361892,0.07077462609004952,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-600/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,600.0,565.9,2.81,,,60.0,18.33,41.5,17.4,34.5,0.009095345999999999,-0.10762195000000001,43.2,1.5122390312040874,18.33831391589308,2.196518057305482e-11,0.13204740780447166,291.1298408745413,6.176482793686994,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-605/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,605.0,577.0,2.56,,,72.0,14.61,52.5,13.82,43.8,0.005544495,-0.120981,43.3,1.7726664585823808,14.62453735740843,1.9758333136732418e-12,0.2205162705712026,221.61818181519084,0.13646978074672794,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-605/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,605.0,570.7,2.81,,,60.0,18.37,41.7,17.44,34.7,0.009115194,-0.10814061000000001,43.2,1.5201778381488757,18.378136621949345,2.2274259043034537e-11,0.13018152149781226,293.91000101942615,6.2783036768263765,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-610/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,610.0,581.9,2.56,,,72.0,14.66,52.7,13.87,44.0,0.00556347,-0.12144188,43.3,1.7798833011781723,14.67424826055086,1.9982743471177734e-12,0.2178972629033539,224.19395441101062,0.20157512827769278,-0.28091,N,2025.7.3,6/23/2025,4.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD120-610/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,610.0,575.6,2.81,,,60.0,18.41,41.9,17.48,34.9,0.009135042,-0.10865927,43.2,1.528115590016918,18.41796121265391,2.258440976633631e-11,0.12832465780418528,296.7458699712889,6.378994344899239,-0.33201,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM7-UHLDD144-615/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,615.0,586.7,2.56,,,72.0,14.72,52.9,13.92,44.2,0.005586239999999999,-0.12190276000000001,43.3,1.7876328571015256,14.734701621897358,2.0384962691164183e-12,0.21513055018501784,215.3994792530812,0.3364362412160692,-0.28091,N,2025.7.3,6/23/2025,2.0,first_pass +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-630/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,630.0,596.8,3.08,,,66.0,18.07,44.4,17.08,36.9,0.00446329,-0.114108,42.7,1.5358736443663055,18.08783254729451,4.962370438140642e-12,0.15503887412642206,157.10332423459738,-4.652923085564094,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-635/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,635.0,601.7,3.08,,,66.0,18.12,44.6,17.12,37.1,0.00447564,-0.114622,42.7,1.5437565403211404,18.138290347333715,5.063869096359697e-12,0.15305245812503185,151.6270027291697,-4.513319987249645,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-640/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,640.0,606.5,3.08,,,66.0,18.17,44.8,17.16,37.3,0.004487990000000001,-0.11513599999999999,42.7,1.5516421276111727,18.18872719593763,5.166728700787451e-12,0.15107497359404287,146.57999430069464,-4.3748371658815755,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-645/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,645.0,611.4,3.08,,,66.0,18.22,45.0,17.21,37.5,0.00450034,-0.11565,42.7,1.5591168214967186,18.23836394709288,5.2343218457929825e-12,0.14912182934422516,147.95292756807075,-4.294660852429336,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-650/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,650.0,616.2,3.08,,,66.0,18.27,45.2,17.25,37.7,0.00451269,-0.116164,42.7,1.5670053229934715,18.288772597138156,5.33918613892286e-12,0.14716344551773902,143.22345166074058,-4.157961858281431,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-655/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,655.0,621.0,3.08,,,66.0,18.32,45.4,17.29,37.9,0.00452504,-0.116678,42.7,1.5748963631230088,18.339161233207662,5.44541854728673e-12,0.14521367197293097,138.83837460166865,-4.02211378649712,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-660/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,660.0,625.9,3.08,,,66.0,18.37,45.6,17.33,38.1,0.00453739,-0.117192,42.7,1.582789925698814,18.389530183638982,5.553026125239188e-12,0.1432724498415392,134.76140089014862,-3.887109663361515,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-665/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,665.0,630.7,3.08,,,66.0,18.42,45.8,17.37,38.3,0.004549740000000001,-0.11770599999999999,42.7,1.590685993764323,18.43987976810304,5.662015923050313e-12,0.1413397191503695,130.9611669681102,-3.752936575502034,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-TPLDD132-670/M,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,0,670.0,635.6,3.08,,,66.0,18.47,46.0,17.41,38.5,0.00456209,-0.11822,42.7,1.5985845429130847,18.490210299981328,5.772394421807387e-12,0.13941541631772045,127.4104167098953,-3.619569214569744,-0.311,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-695/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,695.0,664.1,3.1,,,66.0,18.23,48.1,17.25,40.3,0.008030315000000001,-0.10807108,43.4,1.5985423090346835,18.248069465596718,1.534358670649977e-12,0.1545093730730444,155.88207945704806,-1.3653762812927903,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-700/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,700.0,669.0,3.1,,,66.0,18.27,48.3,17.29,40.5,0.008047934999999999,-0.10852044,43.4,1.6056843041449584,18.28776386273137,1.5521790408531973e-12,0.15269463122848262,157.04528654475516,-1.2880527076270811,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-705/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,705.0,673.9,3.1,,,66.0,18.31,48.5,17.33,40.7,0.008065554999999999,-0.10896979999999999,43.4,1.612825461330946,18.327461684097173,1.5700456584160925e-12,0.15088864918894826,158.21905557257705,-1.2114422567683365,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-710/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,710.0,678.8,3.1,,,66.0,18.35,48.7,17.37,40.9,0.008083175000000001,-0.10941916,43.4,1.619965917130643,18.36716290497165,1.5879611694931783e-12,0.1490913412468966,159.40344112441656,-1.1356507799707751,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-715/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,715.0,683.6,3.1,,,66.0,18.39,48.9,17.4,41.1,0.008100795000000001,-0.10986852,43.4,1.6275116326898695,18.407573712180092,1.6169289951315654e-12,0.14728416699429472,154.12542343312924,-1.00105651325446,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-720/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,720.0,688.5,3.1,,,66.0,18.43,49.1,17.44,41.3,0.008118414999999999,-0.11031788000000001,43.4,1.6346516887825928,18.44727096237043,1.6350390111701029e-12,0.14550271116646502,155.26725767261857,-0.9267407745552139,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-725/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,725.0,693.4,3.1,,,66.0,18.47,49.3,17.47,41.5,0.008136035,-0.11076723999999999,43.4,1.6422006922256847,18.48765637963297,1.664515622172243e-12,0.14370860279254877,150.33081240615743,-0.7940423791073085,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-730/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,730.0,698.3,3.1,,,66.0,18.51,49.5,17.51,41.7,0.008153655000000001,-0.1112166,43.4,1.6493400619034357,18.527349996958083,1.682809954703801e-12,0.14194269775654544,151.43284076069023,-0.7208798518787026,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-735/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,735.0,703.2,3.1,,,66.0,18.55,49.7,17.55,41.9,0.008171275,-0.11166596000000001,43.4,1.6564790038688368,18.56704706364468,1.701154982961818e-12,0.1401853596673684,152.54465383179263,-0.6487639389072136,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping +ZNSHINE PV-TECH Co Ltd ZXM8-GPLDD132-740/N,ZNSHINE PV-TECH Co Ltd,Mono-c-Si,1,740.0,708.0,3.1,,,66.0,18.95,49.9,17.58,42.1,0.008347475,-0.11211531999999999,43.4,1.6783767864448522,18.989825365301755,2.2299625684318517e-12,0.13479322007843994,64.13830737479124,1.5402250878223371,-0.26186,N,2025.7.3,6/23/2025,4.0,bootstrapping diff --git a/src/akkudoktoreos/data/emhass_inverters.csv b/src/akkudoktoreos/data/emhass_inverters.csv new file mode 100644 index 00000000..e8d4c2a1 --- /dev/null +++ b/src/akkudoktoreos/data/emhass_inverters.csv @@ -0,0 +1,10 @@ +Name,Vac,Pso,Paco,Pdco,Vdco,C0,C1,C2,C3,Pnt,Vdcmax,Idcmax,Mppt_low,Mppt_high,CEC_Date,CEC_hybrid,CEC_Type +Units,V,W,W,W,V,1/W,1/V,1/V,1/V,W,V,A,V,V,,, +[0],inv_snl_ac_voltage,inv_snl_pso,inv_snl_paco,inv_snl_pdco,inv_snl_vdco,inv_snl_c0,inv_snl_c1,inv_snl_c2,inv_snl_c3,inv_snl_pnt,inv_snl_vdcmax,inv_snl_idcmax,inv_snl_mppt_low,inv_snl_mppt_hi,inv_cec_date,inv_cec_hybrid,inv_cec_type +Sungrow: SH25T,400,250,27500,26000,600,-0.0000828,-0.000759,-0.0001722,-0.0000414,25,1100,80,200,950,01/01/2025,Y,Hybrid +Sungrow: SH20T,400,200,22000,21000,600,-0.00007584,-0.0007245,-0.0001587,-0.00003834,25,1100,80,200,950,01/01/2025,Y,Hybrid +Sungrow: SH15T,400,150,16500,15700,600,-0.000069,-0.00069,-0.000138,-0.0000345,25,1100,80,200,950,01/01/2025,Y,Hybrid +Sungrow: SH10RT,400,100,11000,10467,600,-0.00005892,-0.0006555,-0.0001173,-0.00002934,25,1100,80,200,950,01/01/2025,Y,Hybrid +Sungrow: SH6RT,400,55,6000,6120,600,-0.000108,-0.001202,-0.000215,-0.0000538,25,1000,25,200,950,01/01/2025,Y,Hybrid +Sungrow: SH10RS,400,100,10000,9500,600,-0.000065,-0.00075,-0.00013,-0.000032,25,1000,25,250,850,01/01/2025,N,Grid-Tie +Fox ESS: KH/KA10,240,32,10500,15000,360,-0.000001128,-0.000001128,0.0025,0.0025,15,600,20,80,500,01/01/2025,Y,Hybrid \ No newline at end of file diff --git a/src/akkudoktoreos/data/emhass_modules.csv b/src/akkudoktoreos/data/emhass_modules.csv new file mode 100644 index 00000000..fa080406 --- /dev/null +++ b/src/akkudoktoreos/data/emhass_modules.csv @@ -0,0 +1,9 @@ +Name,Manufacturer,Technology,Bifacial,STC,PTC,A_c,Length,Width,N_s,I_sc_ref,V_oc_ref,I_mp_ref,V_mp_ref,alpha_sc,beta_oc,T_NOCT,a_ref,I_L_ref,I_o_ref,R_s,R_sh_ref,Adjust,gamma_pmp,BIPV,Version,Date +Units,,,,,,m2,m,m,,A,V,A,V,A/K,V/K,C,V,A,A,Ohm,Ohm,%,%/K,,, +[0],lib_manufacturer,cec_material,lib_is_bifacial,,,cec_area,lib_length,lib_width,cec_n_s,cec_i_sc_ref,cec_v_oc_ref,cec_i_mp_ref,cec_v_mp_ref,cec_alpha_sc,cec_beta_oc,cec_t_noct,cec_a_ref,cec_i_l_ref,cec_i_o_ref,cec_r_s,cec_r_sh_ref,cec_adjust,cec_gamma_pmp,,, +Jinko Solar JKM475N-60HL4-V,Jinko Solar,Mono-c-Si,0,475.0,432.0,2.16,1.903,1.134,120,14.23,42.54,13.49,35.21,0.046,-0.17,45.0,1.3,14.23,2e-7,0.2,300.0,1,-0.003,N,2021.08.01,01/03/2021 +Hanwha Q CELLS Q.PEAK L-G5 300W,Hanwha Q CELLS,Mono-c-Si,N,300.0,273.0,1.67,1.67,1.0,72,9.57,39.58,9.01,33.29,0.0006,-0.33,45.0,1.2,9.58,1e-10,0.5,1500,1,-0.38,N,2019.08.01,01/03/2019 +Risen RSM40-8-390M,Risen,Mono-c-Si,0,390.0,355.0,1.82,1.755,1.038,80,13.98,40.70,13.19,31.8,0.048,-0.15,45.0,1.25,13.98,1.9e-7,0.38,445.0,1,-0.35,N,2024.01.01,01/04/2024 +AIKO-A475-MAH54Mw,AIKO,Mono-c-Si,0,475.0,432.3,1.99,1.757,1.134,108,14.35,41.24,13.66,34.80,0.0072,-0.091,45.0,1.2,14.35,5.0e-10,0.20,1000,1,-0.26,N,2024.12.01,14/05/2025 +Jolywood JW-HD108N-420W,Jolywood,Mono-c-Si,1,420.0,382.0,1.96,1.728,1.134,108,13.98,37.9,13.17,31.9,0.0064,-0.10,42.0,1.2,13.98,5.0e-10,0.20,1000,1,-0.32,N,2022.10.01,09/12/2025 +Huasun HS-182-B108-DSN440,Huasun,Mono-c-Si,1,440.0,400.0,1.95,1.722,1.134,108,13.05,41.91,12.53,35.12,0.0052,-0.10,44.0,1.3,13.05,1e-9,0.22,900,1,-0.26,N,2023.04.17,01/01/2026 \ No newline at end of file diff --git a/src/akkudoktoreos/devices/devicesabc.py b/src/akkudoktoreos/devices/devicesabc.py index 94baa620..f4a668e1 100644 --- a/src/akkudoktoreos/devices/devicesabc.py +++ b/src/akkudoktoreos/devices/devicesabc.py @@ -1,5 +1,7 @@ """Abstract and base classes for devices.""" +import secrets +import string from enum import StrEnum from pydantic import Field @@ -7,11 +9,18 @@ from pydantic import Field from akkudoktoreos.config.configabc import SettingsBaseModel +def device_default_id() -> str: + """Provide random default device id.""" + alphabet = string.ascii_letters + string.digits + device_id = "".join(secrets.choice(alphabet) for _ in range(10)) + return device_id + + class DevicesBaseSettings(SettingsBaseModel): """Base devices setting.""" device_id: str = Field( - default="", + default_factory=device_default_id, json_schema_extra={ "description": "ID of device", "examples": ["battery1", "ev1", "inverter1", "dishwasher"], diff --git a/src/akkudoktoreos/optimization/genetic/geneticparams.py b/src/akkudoktoreos/optimization/genetic/geneticparams.py index d83f01a4..27078f2d 100644 --- a/src/akkudoktoreos/optimization/genetic/geneticparams.py +++ b/src/akkudoktoreos/optimization/genetic/geneticparams.py @@ -293,6 +293,24 @@ class GeneticOptimizationParameters( # Assure predictions are uptodate await cls.prediction.update_data() + try: # Try first - predition is also needed by the default PV forecast + array = await cls.prediction.key_to_array( + key="weather_temp_air", + start_datetime=parameter_start_datetime, + end_datetime=parameter_end_datetime, + interval=interval, + fill_method="ffill", + ) + weather_temp_air = array.tolist() + except Exception as e: + logger.info( + "No weather forecast data available - defaulting to demo data. Parameter preparation attempt {}: {}", + attempt, + e, + ) + cls.config.weather.provider = "OpenMeteo" + # Retry + continue try: array = await cls.prediction.key_to_array( key="pvforecast_ac_power", @@ -311,36 +329,52 @@ class GeneticOptimizationParameters( cls.config.merge_settings_from_dict( { "pvforecast": { - "provider": "PVForecastAkkudoktor", + "provider": "PVForecastPVLib", "max_planes": 4, "planes": [ { - "peakpower": 5.0, + "surface_tilt": 7, "surface_azimuth": 170, - "surface_tilt": 7, "userhorizon": [20, 27, 22, 20], + "peakpower": 5.0, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, }, { - "peakpower": 4.8, - "surface_azimuth": 90, "surface_tilt": 7, + "surface_azimuth": 90, "userhorizon": [30, 30, 30, 50], + "peakpower": 4.8, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, }, { - "peakpower": 1.4, - "surface_azimuth": 140, "surface_tilt": 60, + "surface_azimuth": 140, "userhorizon": [60, 30, 0, 30], + "peakpower": 1.4, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 2000, + "modules_per_string": 5, + "strings_per_inverter": 1, }, { - "peakpower": 1.6, - "surface_azimuth": 185, "surface_tilt": 45, + "surface_azimuth": 185, "userhorizon": [45, 25, 30, 60], + "peakpower": 1.6, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 1400, + "modules_per_string": 4, + "strings_per_inverter": 1, }, ], }, @@ -363,7 +397,24 @@ class GeneticOptimizationParameters( attempt, e, ) - cls.config.elecprice.provider = "ElecPriceAkkudoktor" + cls.config.merge_settings_from_dict( + { + "elecprice": { + "elecpricefixed": { + "time_windows": { + "windows": [ + { + "duration": "1 day", + "start_time": "00:00:00.000000", + "value": 0.288, + } + ] + } + }, + "provider": "ElecPriceFixed", + }, + }, + ) # Retry continue try: @@ -420,24 +471,6 @@ class GeneticOptimizationParameters( ) # Retry continue - try: - array = await cls.prediction.key_to_array( - key="weather_temp_air", - start_datetime=parameter_start_datetime, - end_datetime=parameter_end_datetime, - interval=interval, - fill_method="ffill", - ) - weather_temp_air = array.tolist() - except Exception as e: - logger.info( - "No weather forecast data available - defaulting to demo data. Parameter preparation attempt {}: {}", - attempt, - e, - ) - cls.config.weather.provider = "BrightSky" - # Retry - continue # Add device data diff --git a/src/akkudoktoreos/optimization/genetic0/genetic0params.py b/src/akkudoktoreos/optimization/genetic0/genetic0params.py index a11d6fae..e1735ec4 100644 --- a/src/akkudoktoreos/optimization/genetic0/genetic0params.py +++ b/src/akkudoktoreos/optimization/genetic0/genetic0params.py @@ -284,6 +284,24 @@ class Genetic0OptimizationParameters( # Assure predictions are uptodate await cls.prediction.update_data() + try: # Try first - predition is also needed by the default PV forecast + array = await cls.prediction.key_to_array( + key="weather_temp_air", + start_datetime=parameter_start_datetime, + end_datetime=parameter_end_datetime, + interval=interval, + fill_method="ffill", + ) + weather_temp_air = array.tolist() + except Exception as e: + logger.info( + "No weather forecast data available - defaulting to demo data. Parameter preparation attempt {}: {}", + attempt, + e, + ) + cls.config.weather.provider = "OpenMeteo" + # Retry + continue try: array = await cls.prediction.key_to_array( key="pvforecast_ac_power", @@ -302,36 +320,52 @@ class Genetic0OptimizationParameters( cls.config.merge_settings_from_dict( { "pvforecast": { - "provider": "PVForecastAkkudoktor", + "provider": "PVForecastPVLib", "max_planes": 4, "planes": [ { - "peakpower": 5.0, + "surface_tilt": 7, "surface_azimuth": 170, - "surface_tilt": 7, "userhorizon": [20, 27, 22, 20], + "peakpower": 5.0, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, }, { - "peakpower": 4.8, - "surface_azimuth": 90, "surface_tilt": 7, + "surface_azimuth": 90, "userhorizon": [30, 30, 30, 50], + "peakpower": 4.8, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, }, { - "peakpower": 1.4, - "surface_azimuth": 140, "surface_tilt": 60, + "surface_azimuth": 140, "userhorizon": [60, 30, 0, 30], + "peakpower": 1.4, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 2000, + "modules_per_string": 5, + "strings_per_inverter": 1, }, { - "peakpower": 1.6, - "surface_azimuth": 185, "surface_tilt": 45, + "surface_azimuth": 185, "userhorizon": [45, 25, 30, 60], + "peakpower": 1.6, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", "inverter_paco": 1400, + "modules_per_string": 4, + "strings_per_inverter": 1, }, ], }, @@ -354,7 +388,24 @@ class Genetic0OptimizationParameters( attempt, e, ) - cls.config.elecprice.provider = "ElecPriceAkkudoktor" + cls.config.merge_settings_from_dict( + { + "elecprice": { + "elecpricefixed": { + "time_windows": { + "windows": [ + { + "duration": "1 day", + "start_time": "00:00:00.000000", + "value": 0.288, + } + ] + } + }, + "provider": "ElecPriceFixed", + }, + }, + ) # Retry continue try: @@ -411,24 +462,6 @@ class Genetic0OptimizationParameters( ) # Retry continue - try: - array = await cls.prediction.key_to_array( - key="weather_temp_air", - start_datetime=parameter_start_datetime, - end_datetime=parameter_end_datetime, - interval=interval, - fill_method="ffill", - ) - weather_temp_air = array.tolist() - except Exception as e: - logger.info( - "No weather forecast data available - defaulting to demo data. Parameter preparation attempt {}: {}", - attempt, - e, - ) - cls.config.weather.provider = "BrightSky" - # Retry - continue # Add device data diff --git a/src/akkudoktoreos/optimization/optimization.py b/src/akkudoktoreos/optimization/optimization.py index c0cebcb5..51770b86 100644 --- a/src/akkudoktoreos/optimization/optimization.py +++ b/src/akkudoktoreos/optimization/optimization.py @@ -1,3 +1,4 @@ +from enum import StrEnum from typing import Optional from pydantic import Field, computed_field @@ -13,22 +14,29 @@ from akkudoktoreos.optimization.genetic.geneticsettings import GeneticCommonSett from akkudoktoreos.utils.datetimeutil import DateTime -def optimization_algorithms() -> list[str]: - """Valid optimization algorithms.""" - # Return static built-in optimization algorithms. - return [ - "GENETIC", - "GENETIC0", - ] +class OptimizationAlgorithm(StrEnum): + """Optimization Algorithm.""" + + GENETIC = "GENETIC" + GENETIC0 = "GENETIC0" + + +def optimization_default_algorithm() -> OptimizationAlgorithm: + """Provide default optimization algorithm.""" + return OptimizationAlgorithm.GENETIC class OptimizationCommonSettings(SettingsBaseModel): """General Optimization Configuration.""" - algorithm: str = Field( - default="GENETIC", + algorithm: OptimizationAlgorithm = Field( + default_factory=optimization_default_algorithm, json_schema_extra={ - "description": "The optimization algorithm. Defaults to GENETIC", + "description": ( + f"Optimization algorithm " + f"[{' | '.join(mode.value for mode in OptimizationAlgorithm)}]. " + f"Defaults to {optimization_default_algorithm()}." + ), "examples": ["GENETIC", "GENETIC0"], }, ) @@ -54,7 +62,7 @@ class OptimizationCommonSettings(SettingsBaseModel): @property def algorithms(self) -> list[str]: """Available optimization algorithms.""" - return optimization_algorithms() + return [algo.value for algo in OptimizationAlgorithm] @computed_field # type: ignore[prop-decorator] @property diff --git a/src/akkudoktoreos/prediction/prediction.py b/src/akkudoktoreos/prediction/prediction.py index 3fe97eab..eba963ac 100644 --- a/src/akkudoktoreos/prediction/prediction.py +++ b/src/akkudoktoreos/prediction/prediction.py @@ -52,6 +52,7 @@ from akkudoktoreos.prediction.predictionabc import PredictionContainer from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor from akkudoktoreos.prediction.pvforecastforecastsolar import PVForecastForecastSolar from akkudoktoreos.prediction.pvforecastimport import PVForecastImport +from akkudoktoreos.prediction.pvforecastpvlib import PVForecastPVLib from akkudoktoreos.prediction.pvforecastpvnode import PVForecastPVNode from akkudoktoreos.prediction.pvforecastsolcast import PVForecastSolcast from akkudoktoreos.prediction.pvforecastvrm import PVForecastVrm @@ -97,6 +98,7 @@ loadforecast_vrm = LoadVrm() loadforecast_import = LoadImport() pvforecast_akkudoktor = PVForecastAkkudoktor() pvforecast_vrm = PVForecastVrm() +pvforecast_pvlib = PVForecastPVLib() pvforecast_pvnode = PVForecastPVNode() pvforecast_forecastsolar = PVForecastForecastSolar() pvforecast_solcast = PVForecastSolcast() @@ -122,18 +124,19 @@ def prediction_providers() -> list[ FeedInTariffTibber, LoadAkkudoktor, LoadAkkudoktorAdjusted, - LoadVrm, LoadImport, + LoadVrm, PVForecastAkkudoktor, - PVForecastVrm, - PVForecastPVNode, PVForecastForecastSolar, - PVForecastSolcast, PVForecastImport, + PVForecastPVLib, + PVForecastPVNode, + PVForecastSolcast, + PVForecastVrm, WeatherBrightSky, WeatherClearOutside, - WeatherOpenMeteo, WeatherImport, + WeatherOpenMeteo, ] ]: """Return list of prediction providers. @@ -158,6 +161,7 @@ def prediction_providers() -> list[ loadforecast_import, \ pvforecast_akkudoktor, \ pvforecast_vrm, \ + pvforecast_pvlib, \ pvforecast_pvnode, \ pvforecast_forecastsolar, \ pvforecast_solcast, \ @@ -168,7 +172,14 @@ def prediction_providers() -> list[ weather_import # Care for provider sequence as providers may rely on others to be updated before. + # + # Inter provider dependencies: + # - pvforecast_pvlib depends on weather return [ + weather_brightsky, # weather maybe needed by the pvforcast, keep it before + weather_clearoutside, + weather_import, + weather_openmeteo, elecprice_akkudoktor, elecprice_energy_charts, elecprice_fixed, @@ -182,18 +193,15 @@ def prediction_providers() -> list[ feedintariff_tibber, loadforecast_akkudoktor, loadforecast_akkudoktor_adjusted, - loadforecast_vrm, loadforecast_import, + loadforecast_vrm, pvforecast_akkudoktor, - pvforecast_vrm, - pvforecast_pvnode, pvforecast_forecastsolar, - pvforecast_solcast, pvforecast_import, - weather_brightsky, - weather_clearoutside, - weather_openmeteo, - weather_import, + pvforecast_pvlib, + pvforecast_pvnode, + pvforecast_solcast, + pvforecast_vrm, ] @@ -215,18 +223,19 @@ class Prediction(PredictionContainer): FeedInTariffTibber, LoadAkkudoktor, LoadAkkudoktorAdjusted, - LoadVrm, LoadImport, + LoadVrm, PVForecastAkkudoktor, - PVForecastVrm, - PVForecastPVNode, PVForecastForecastSolar, - PVForecastSolcast, PVForecastImport, + PVForecastPVLib, + PVForecastPVNode, + PVForecastSolcast, + PVForecastVrm, WeatherBrightSky, WeatherClearOutside, - WeatherOpenMeteo, WeatherImport, + WeatherOpenMeteo, ] ] = Field( default_factory=prediction_providers, diff --git a/src/akkudoktoreos/prediction/pvforecast.py b/src/akkudoktoreos/prediction/pvforecast.py index 0f752959..28a00ef4 100644 --- a/src/akkudoktoreos/prediction/pvforecast.py +++ b/src/akkudoktoreos/prediction/pvforecast.py @@ -11,6 +11,7 @@ from akkudoktoreos.prediction.pvforecastforecastsolar import ( PVForecastForecastSolarCommonSettings, ) from akkudoktoreos.prediction.pvforecastimport import PVForecastImportCommonSettings +from akkudoktoreos.prediction.pvforecastpvlib import PVForecastPVLibCommonSettings from akkudoktoreos.prediction.pvforecastpvnode import PVForecastPVNodeCommonSettings from akkudoktoreos.prediction.pvforecastsolcast import PVForecastSolcastCommonSettings from akkudoktoreos.prediction.pvforecastvrm import PVForecastVrmCommonSettings @@ -25,11 +26,12 @@ def pvforecast_provider_ids() -> list[str]: # Return at least provider used in example return [ "PVForecastAkkudoktor", - "PVForecastImport", - "PVForecastVrm", - "PVForecastPVNode", "PVForecastForecastSolar", + "PVForecastImport", + "PVForecastPVLib", + "PVForecastPVNode", "PVForecastSolcast", + "PVForecastVrm", ] return [ @@ -82,7 +84,7 @@ class PVForecastPlaneSetting(SettingsBaseModel): }, ) mountingplace: Optional[str] = Field( - default="free", + default="building", json_schema_extra={ "description": "Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated." }, @@ -114,7 +116,7 @@ class PVForecastPlaneSetting(SettingsBaseModel): }, ) albedo: Optional[float] = Field( - default=None, + default=0.2, json_schema_extra={ "description": "Proportion of the light hitting the ground that it reflects back.", "examples": [None], @@ -206,6 +208,11 @@ class PVForecastCommonSettings(SettingsBaseModel): json_schema_extra={"description": "Victron Remote Management (VRM) provider settings"}, ) + pvlib: PVForecastPVLibCommonSettings = Field( + default_factory=PVForecastPVLibCommonSettings, + json_schema_extra={"description": "PVLib provider settings"}, + ) + pvnode: PVForecastPVNodeCommonSettings = Field( default_factory=PVForecastPVNodeCommonSettings, json_schema_extra={"description": "PVNode provider settings"}, diff --git a/src/akkudoktoreos/prediction/pvforecastpvlib.py b/src/akkudoktoreos/prediction/pvforecastpvlib.py new file mode 100644 index 00000000..d40210ad --- /dev/null +++ b/src/akkudoktoreos/prediction/pvforecastpvlib.py @@ -0,0 +1,517 @@ +"""Calculates pvforecast forecast data using PVLib.""" + +import bz2 +import pickle +from pathlib import Path +from typing import ClassVar, Literal, Optional, Union + +import numpy as np +import pandas as pd +from loguru import logger +from pvlib.location import Location +from pvlib.modelchain import ModelChain +from pvlib.pvsystem import PVSystem, retrieve_sam +from pvlib.solarposition import get_solarposition +from pvlib.temperature import TEMPERATURE_MODEL_PARAMETERS + +from akkudoktoreos.config.configabc import SettingsBaseModel +from akkudoktoreos.core.coreabc import PredictionMixin, get_config +from akkudoktoreos.prediction.pvforecastabc import PVForecastProvider +from akkudoktoreos.utils.datetimeutil import to_duration + +DeviceType = Literal["module", "inverter"] + + +# Memory cache for CEC databases +_cec_cache: dict[Path, tuple[int, pd.DataFrame]] = {} + + +def _cec_modules_path() -> Path: + """Provide path to the modules database.""" + try: + return get_config().general.data_folder_path / "cec_modules.pbz2" + except Exception: + # Config may not be initialized + return Path("modules_invalid_dummy_path") + + +def _cec_inverters_path() -> Path: + """Provide path to the inverters database.""" + try: + return get_config().general.data_folder_path / "cec_inverters.pbz2" + except Exception: + # Config may not be initialized + return Path("inverters_invalid_dummy_path") + + +def _update_cec_database() -> None: + """Build the EOS CEC module and inverter databases. + + This follows the EMHASS database generation procedure: + + - start with the current SAM database + - restore models missing from the new SAM database + but present in the PVLib database + - add EMHASS custom module/inverter definitions + - store compressed pickle databases + + Script taken from https://github.com/davidusb-geek/emhass/blob/master/scripts/save_pvlib_module_inverter_database.py + """ + data_path = Path(__file__).parent.parent / "data" + + logger.info("Reading original outdated database bundled with PVLib") + cec_modules_old = retrieve_sam("CECMod") + cec_inverters_old = retrieve_sam("cecinverter") + + # Download from https://github.com/NatLabRockies/SAM/tree/develop/samples/CEC%20Module%20and%20Inverter%20Libraries/CEC%20Modules + logger.info("Reading downloaded modules database from SAM") + cec_modules = retrieve_sam(path=str(data_path / "cec_modules.csv")) + cec_modules = cec_modules.loc[:, ~cec_modules.columns.duplicated()] + + # DOwnload from https://github.com/NatLabRockies/SAM/tree/develop/samples/CEC%20Module%20and%20Inverter%20Libraries/CEC%20Inverters + logger.info("Reading downloaded inverters database from SAM") + cec_inverters = retrieve_sam(path=str(data_path / "cec_inverters.csv")) + cec_inverters = cec_inverters.loc[:, ~cec_inverters.columns.duplicated()] + + # Download from https://github.com/davidusb-geek/emhass/tree/master/src/emhass/data + logger.info("Reading custom EMHASS database") + cec_modules_emhass = retrieve_sam(path=str(data_path / "emhass_modules.csv")) + cec_inverters_emhass = retrieve_sam(path=str(data_path / "emhass_inverters.csv")) + + # + # Modules + # + + cols_to_keep = [col for col in cec_modules_old.columns if col not in cec_modules.columns] + + cec_modules = pd.concat( + [ + cec_modules, + cec_modules_old[cols_to_keep], + ], + axis=1, + ) + + logger.info(f"Copied {len(cols_to_keep)} old PVLib module entries") + + cols_to_keep = [col for col in cec_modules_emhass.columns if col not in cec_modules.columns] + + cec_modules = pd.concat( + [ + cec_modules, + cec_modules_emhass[cols_to_keep], + ], + axis=1, + ) + + logger.info(f"Copied {len(cols_to_keep)} custom EMHASS module entries") + + # + # Inverters + # + cols_to_keep = [col for col in cec_inverters_old.columns if col not in cec_inverters.columns] + + cec_inverters = pd.concat( + [ + cec_inverters, + cec_inverters_old[cols_to_keep], + ], + axis=1, + ) + + logger.info(f"Copied {len(cols_to_keep)} old PVLib inverter entries") + + cols_to_keep = [col for col in cec_inverters_emhass.columns if col not in cec_inverters.columns] + + cec_inverters = pd.concat( + [ + cec_inverters, + cec_inverters_emhass[cols_to_keep], + ], + axis=1, + ) + + logger.info(f"Copied {len(cols_to_keep)} custom EMHASS inverter entries") + + # + # Save databases + # + with bz2.BZ2File(_cec_modules_path(), "wb") as file: + pickle.dump(cec_modules, file) + + with bz2.BZ2File(_cec_inverters_path(), "wb") as file: + pickle.dump(cec_inverters, file) + + logger.info(f"CEC databases written: {_cec_modules_path()}, {_cec_inverters_path()}") + + +def _load_cec_database(path: Path) -> pd.DataFrame: + """Load a CEC database, reloading only if the file changed. + + If database does not exists it is created. + """ + if not path.exists(): + # Create databases + _update_cec_database() + + mtime = path.stat().st_mtime_ns + + cached = _cec_cache.get(path) + if cached is not None: + cached_mtime, database = cached + if cached_mtime == mtime: + return database + + with bz2.BZ2File(path, "rb") as f: + database = pickle.load(f) # noqa: S301 + + _cec_cache[path] = (mtime, database) + return database + + +def _cec_modules() -> pd.DataFrame: + """Provide CEC modules database.""" + return _load_cec_database(_cec_modules_path()) + + +def _cec_inverters() -> pd.DataFrame: + """Provide CEC inverters database.""" + return _load_cec_database(_cec_inverters_path()) + + +class PVForecastPVLibCommonSettings(SettingsBaseModel): + """Common settings for pvforecast data calculation with PVLib.""" + + # Nothing in here + + +class PVForecastPVLib(PredictionMixin, PVForecastProvider): + """Calculate PV forecast data using PVLib.""" + + _warned_features: ClassVar[set[str]] = set() + + @classmethod + def provider_id(cls) -> str: + """Return the unique identifier for the PVForecastPVLib provider.""" + return "PVForecastPVLib" + + def _warn_once(self, feature: str, message: str) -> None: + """Log a warning only once for this process.""" + if feature not in self._warned_features: + self._warned_features.add(feature) + logger.warning(message) + + def _get_model_power(self, params: pd.Series, device_type: DeviceType) -> Optional[float]: + """Helper to extract power rating based on device type and available parameters.""" + if device_type == "module": + if "STC" in params: + return params["STC"] + if "I_mp_ref" in params and "V_mp_ref" in params: + return params["I_mp_ref"] * params["V_mp_ref"] + elif device_type == "inverter": + if "Paco" in params: + return params["Paco"] + if "Pdco" in params: + return params["Pdco"] + return None + + def _find_closest_model( + self, target_power: float, database: pd.DataFrame, device_type: DeviceType + ) -> Optional[pd.Series]: + """Find the model in the database that has a power rating closest to the target_power.""" + closest_model = None + min_diff = float("inf") + # Handle DataFrame + for _, params in database.items(): + power = self._get_model_power(params, device_type) + if power is not None: + diff = abs(power - target_power) + if diff < min_diff: + min_diff = diff + closest_model = params + if closest_model is not None: + # Safely get name if it exists (DataFrame Series usually have a .name attribute) + model_name = getattr(closest_model, "name", "unknown") + logger.info(f"Closest {device_type} model to {target_power}W found: {model_name}") + else: + logger.warning(f"No suitable {device_type} model found close to {target_power}W") + return closest_model + + def _get_model( + self, model_spec: Union[str, int, float], database: pd.DataFrame, device_type: DeviceType + ) -> Optional[pd.Series]: + """Retrieve a model from the database by name or by power rating.""" + # If it's a string, try to find it by name + if isinstance(model_spec, str): + if model_spec in database: + return database[model_spec] + # If not found by name, check if it is a number string (e.g., "300") + try: + target_power = float(model_spec) + return self._find_closest_model(target_power, database, device_type) + except ValueError: + # Not a number, fallback to original behavior (will likely raise KeyError later) + logger.warning(f"{device_type} model '{model_spec}' not found in database.") + return database[model_spec] + # If it's a number (int or float), find closest by power + elif isinstance(model_spec, int | float): + return self._find_closest_model(model_spec, database, device_type) + else: + logger.error(f"Invalid type for {device_type} model: {type(model_spec)}") + return None + + def _calculate_pvlib_power(self, df_weather: pd.DataFrame) -> pd.DataFrame: + """Simulate PV power generation using PVLib. + + Returns: + Dataframe with pv_dc_power, ac_power + + Note: + Taken from emhass + """ + # Validate weather data + required = [ + "temp_air", + "ghi", + "dni", + "dhi", + ] + missing = df_weather[required].isna().any() + if missing.any(): + raise ValueError(f"PV weather contains NaN values: {missing[missing].index.tolist()}") + df_weather[required] = df_weather[required].astype(float) + + # Setting the main parameters of the PV plant + location = Location( + latitude=self.config.general.latitude, longitude=self.config.general.longitude + ) + temp_params = TEMPERATURE_MODEL_PARAMETERS["sapm"]["close_mount_glass_glass"] + + def run_single_config(plane_idx: int) -> pd.DataFrame: + """Inner helper to run a single simulation configuration. + + Returns: + Dataframe with times, weather, solar_position, airmass, total_irrad, aoi, + aoi_modifier, spectral_modifier, and effective_irradiance, cell_temperature, + dc, ac, losses, diode_params (if dc_model is a single diode model). + """ + plane = self.config.pvforecast.planes[plane_idx] + + # Check configuration + # - warnings + if plane.userhorizon is not None: + self._warn_once( + "userhorizon", + f"userhorizon is currently not supported by the {self.provider_id()} provider.", + ) + if plane.optimalangles: + self._warn_once( + "optimalangles", + f"optimalangles is currently not supported by the {self.provider_id()} provider.", + ) + if plane.loss not in (None, 0): + self._warn_once( + "loss", + f"loss is currently not supported by the {self.provider_id()} provider.", + ) + if plane.trackingtype not in (None, 0): + self._warn_once( + "trackingtype", + f"trackingtype is currently not supported by the {self.provider_id()} provider.", + ) + if plane.inverter_paco is not None: + self._warn_once( + "inverter_paco", + f"inverter_paco is currently not supported by the {self.provider_id()} provider.", + ) + # - mandatory parameters + if plane.surface_tilt is None: + raise ValueError(f"Plane {plane_idx}: surface_tilt must be configured.") + if plane.surface_azimuth is None: + raise ValueError(f"Plane {plane_idx}: surface_azimuth must be configured.") + if plane.module_model is None: + raise ValueError(f"Plane {plane_idx}: module_model must be configured.") + module = self._get_model(plane.module_model, _cec_modules(), "module") + + if plane.inverter_model is None: + raise ValueError("fPlane {plane_idx}: inverter_model must be configured.") + inverter = self._get_model(plane.inverter_model, _cec_inverters(), "inverter") + + if plane.modules_per_string is None: + raise ValueError(f"Plane {plane_idx}: modules_per_string must be configured.") + + if plane.strings_per_inverter is None: + raise ValueError(f"Plane {plane_idx}: strings_per_inverter must be configured.") + + mountingplace = plane.mountingplace.lower() + if mountingplace == "building": + temp_params = TEMPERATURE_MODEL_PARAMETERS["sapm"]["close_mount_glass_glass"] + elif mountingplace == "free" or mountingplace is None: + temp_params = TEMPERATURE_MODEL_PARAMETERS["sapm"]["open_rack_glass_glass"] + else: + raise ValueError( + f"Plane {plane_idx}: mountingplace '{plane.mountingplace}' invalid." + ) + if plane.albedo is None: + df_weather["albedo"] = 0.2 # Take a default + self._warn_once( + f"Plane {plane_idx}: albedo", + f"Plane {plane_idx}: albedo set to 0.2 (was None).", + ) + else: + df_weather["albedo"] = plane.albedo + + system = PVSystem( + surface_tilt=plane.surface_tilt, + surface_azimuth=plane.surface_azimuth, + module_parameters=module, + inverter_parameters=inverter, + temperature_model_parameters=temp_params, + modules_per_string=plane.modules_per_string, + strings_per_inverter=plane.strings_per_inverter, + ) + + mc = ModelChain(system, location, aoi_model="physical") + + # For testing split out parameter preparation + # mc.prepare_inputs(df_weather) + # print("surface_tilt:", plane.surface_tilt, type(plane.surface_tilt)) + # print("surface_azimuth:", plane.surface_azimuth, type(plane.surface_azimuth)) + # print("albedo:", plane.albedo, type(plane.albedo)) + # print("weather irradiance") + # print(df_weather[["ghi", "dni", "dhi"]]) + # print("after prepare_inputs") + # print("solar position") + # print(mc.results.solar_position[["zenith", "azimuth"]]) + # print(mc.results.total_irrad) + # print(mc.results.aoi) + # print(mc.results.effective_irradiance) + + mc.run_model(df_weather) + + return mc.results + + df_pvforecast = pd.DataFrame( + { + "pv_dc_power": 0.0, + "ac_power": 0.0, + }, + index=df_weather.index, + ) + for plane_idx in range(len(self.config.pvforecast.planes)): + result = run_single_config(plane_idx) + df_pvforecast["pv_dc_power"] += result.dc["p_mp"].fillna(0.0) + df_pvforecast["ac_power"] += result.ac.fillna(0.0) + + # replace any negative PV values with zero + df_pvforecast["pv_dc_power"] = df_pvforecast["pv_dc_power"].clip(lower=0.0) + df_pvforecast["ac_power"] = df_pvforecast["ac_power"].clip(lower=0.0) + + return df_pvforecast + + @staticmethod + def compute_solar_angles(df: pd.DataFrame, latitude: float, longitude: float) -> pd.DataFrame: + """Compute solar angles (elevation, azimuth) based on timestamps and location. + + :param df: DataFrame with a DateTime index. + :param latitude: Latitude of the PV system. + :param longitude: Longitude of the PV system. + :return: DataFrame with added solar elevation and azimuth. + """ + df = df.copy() + solpos = get_solarposition(df.index, latitude, longitude) + df["solar_elevation"] = solpos["elevation"] + df["solar_azimuth"] = solpos["azimuth"] + return df + + @staticmethod + def add_cyclic_hour_features(df: pd.DataFrame) -> pd.DataFrame: + """Encode the time of day as a continuous sin/cos pair. + + A raw integer hour feature is piecewise constant: with sub-hourly + optimization time steps a (linear) regression model then produces a + discontinuity at every hour boundary, which shows up as a sawtooth in + the adjusted PV forecast. The cyclic encoding is computed from the + fractional hour (hour + minute/60) so it evolves smoothly within the + hour and stays continuous across midnight. + + :param df: DataFrame with a DateTime index. + :type df: pd.DataFrame + :return: DataFrame with added hour_sin and hour_cos columns. + :rtype: pd.DataFrame + """ + if not isinstance(df.index, pd.DatetimeIndex): + raise ValueError("DataFrame must have a DatetimeIndex to compute cyclic hour features.") + df = df.copy() + fractional_hour = df.index.hour + df.index.minute / 60.0 # type: ignore[attr-defined] + df["hour_sin"] = np.sin(2 * np.pi * fractional_hour / 24.0) + df["hour_cos"] = np.cos(2 * np.pi * fractional_hour / 24.0) + return df + + async def _update_data(self, force_update: Optional[bool] = False) -> None: + # Both _sequence_lock and _record_lock are already held by the caller. + # Use internal sync methods only — never await public async counterparts. + + # Assure we have something to request PV power for. + if not self.config.pvforecast.planes: + # No planes for PV + error_msg = "Requested PV forecast, but no planes configured." + logger.error(f"Configuration error: {error_msg}") + raise ValueError(error_msg) + + start_datetime = self.ems_start_datetime.start_of("day") + end_datetime = self.ems_start_datetime.add(hours=self.config.prediction.hours) + + # Prepare weather data for the PV forecast calculation + # + # We need a dataframe with the following columns: + # - "temp_air" temperature_2m + # - "relative_humidity" relative_humidity_2m + # - "precipitable_water" precipitable_water (cm) + # - "cloud_cover" cloud_cover + # - "wind_speed" wind_speed_10m + # - "ghi" shortwave_radiation_instant + # - "dhi" diffuse_radiation_instant + # - "dni" direct_normal_irradiance_instant + # + # Data shall be given in 15-minutes intervals + keys = [ + "weather_temp_air", + "weather_relative_humidity", + "weather_preciptable_water", + "weather_total_clouds", + "weather_wind_speed", + "weather_ghi", + "weather_dhi", + "weather_dni", + ] + df_weather = await self.prediction.keys_to_dataframe( + keys=keys, + start_datetime=start_datetime, + end_datetime=end_datetime, + interval=to_duration("15 minutes"), + fill_method="linear", + resample_method="mean", + dropna=True, + boundary="context", + align_to_interval=True, + ) + df_weather = df_weather.rename( + columns={ + "weather_temp_air": "temp_air", + "weather_relative_humidity": "relative_humidity", + "weather_preciptable_water": "precipitable_water", + "weather_total_clouds": "cloud_cover", + "weather_wind_speed": "wind_speed", + "weather_ghi": "ghi", + "weather_dhi": "dhi", + "weather_dni": "dni", + } + ) + + # Calculate th PV forecast + df_pvforecast = self._calculate_pvlib_power(df_weather) + + for row in df_pvforecast.itertuples(): + await self._update_value(row.Index, "pvforecast_dc_power", float(row.pv_dc_power)) # type: ignore + await self._update_value(row.Index, "pvforecast_ac_power", float(row.ac_power)) # type: ignore diff --git a/src/akkudoktoreos/server/dash/carditems.py b/src/akkudoktoreos/server/dash/carditems.py new file mode 100644 index 00000000..5098ab47 --- /dev/null +++ b/src/akkudoktoreos/server/dash/carditems.py @@ -0,0 +1,123 @@ +"""Shared helpers for list- and map-of-sub-model configuration cards. + +Used by both ``itemscard.py`` (``list[PydanticSubModel]`` fields) and +``mapcard.py`` (``dict[str, PydanticSubModel]`` fields) to avoid duplicating +the Pydantic-introspection and required-field-collection logic between the +two card types. Free of imports from ``configuration.py``, ``itemscard.py``, +or ``mapcard.py`` to avoid circular dependencies. +""" + +from typing import Any, cast + +from monsterui.franken import Div, Input, P +from pydantic import BaseModel +from pydantic_core import PydanticUndefined + + +def resolve_model_cls(item_model: Any) -> type[BaseModel]: + """Resolve a Pydantic model class from either a class or an instance. + + Args: + item_model: A Pydantic model class or an instance of one. + + Returns: + The model class, cast for mypy's benefit (``isinstance(x, type)`` + alone narrows to plain ``type``, not ``type[BaseModel]``). + """ + if isinstance(item_model, type): + return cast(type[BaseModel], item_model) + return cast(type[BaseModel], type(item_model)) + + +def item_model_defaults(item_model: Any) -> tuple[dict, list[str]]: + """Build defaults for a Pydantic sub-model and report required-but-unset fields. + + Constructs a model instance using only fields that have defaults (either + ``default`` or ``default_factory``), then serialises via + ``model_dump(mode="json")`` to produce a fully JSON-safe dict. Fields + without any default are reported separately rather than silently + omitted — a freshly-constructed instance missing them would fail the + model's own validation (e.g. ``consumption_wh``/``duration_h`` on + ``HomeApplianceCommonSettings``), so callers must collect values for + them before persisting a new item or entry. + + Args: + item_model: A Pydantic model class or instance whose ``model_fields`` + will be inspected. + + Returns: + A tuple of ``(defaults, required_missing)`` where ``defaults`` + contains every field that has a ``default`` or ``default_factory``, + JSON-safe and ready to serialise, and ``required_missing`` lists the + field names that have neither. + """ + model_cls = resolve_model_cls(item_model) + + kwargs: dict[str, Any] = {} + required_missing: list[str] = [] + for field_name, field_info in model_cls.model_fields.items(): + if field_info.default is not PydanticUndefined: + kwargs[field_name] = field_info.default + elif field_info.default_factory is not None: + kwargs[field_name] = field_info.default_factory() + else: + required_missing.append(field_name) + + instance = model_cls.model_construct(**kwargs) + defaults = instance.model_dump(mode="json", exclude_unset=True) + return defaults, required_missing + + +def required_field_inputs( + item_model: Any, + required_missing: list[str], + id_prefix: str, +) -> tuple[list[Div], list[str]]: + """Build labelled inputs for a sub-model's required-but-undefaulted fields. + + Produces one ``Div``-wrapped ``Input`` per field in ``required_missing``, + each carrying HTML ``required`` so the browser blocks form submission + until every field has a value, plus the corresponding JS expressions for + reading those inputs back out at submit time. + + Args: + item_model: The Pydantic model class or instance the fields belong + to, used to pick ``type="number"`` vs ``type="text"``. + required_missing: Field names with no default, as returned by + ``item_model_defaults``. + id_prefix: A CSS/DOM-safe prefix (e.g. derived from the config name) + used to build unique element ids for each input. + + Returns: + A tuple of ``(inputs, js_pairs)`` where ``inputs`` is the list of + rendered ``Div`` components to place in the form, and ``js_pairs`` + is a list of ``'"field_name": '`` strings suitable + for splicing into a JS object literal that reads the DOM values. + """ + model_cls = resolve_model_cls(item_model) + + inputs: list[Div] = [] + js_pairs: list[str] = [] + for field_name in required_missing: + field_id = f"{id_prefix}-{field_name}".replace(".", "-").replace("_", "-") + annotation = model_cls.model_fields[field_name].annotation + is_numeric = annotation in (int, float) + inputs.append( + Div( + P(field_name, cls="text-xs text-muted-foreground"), + Input( + id=field_id, + type="number" if is_numeric else "text", + required=True, + placeholder=field_name, + ), + ) + ) + value_expr = ( + f'Number(document.getElementById("{field_id}").value)' + if is_numeric + else f'document.getElementById("{field_id}").value' + ) + js_pairs.append(f'"{field_name}": {value_expr}') + + return inputs, js_pairs diff --git a/src/akkudoktoreos/server/dash/components.py b/src/akkudoktoreos/server/dash/components.py index ccb5cee7..88edf6ca 100644 --- a/src/akkudoktoreos/server/dash/components.py +++ b/src/akkudoktoreos/server/dash/components.py @@ -22,6 +22,7 @@ from monsterui.franken import ( # Select: Does not work - using Select from Fas Form, Grid, Input, + Kbd, Option, P, Pre, @@ -31,6 +32,27 @@ from monsterui.franken import ( # Select: Does not work - using Select from Fas ) from akkudoktoreos.server.dash.context import request_url_for +from akkudoktoreos.server.dash.markdown import Markdown + +# --------------------------------------------------------------------------- +# HTMX CONTEXT +# --------------------------------------------------------------------------- +# All HTMX requests MUST include these elements to preserve UI state. +# +# Currently includes: +# - #config-search → keeps search/filter state across interactions +# +# If you add more global UI state (e.g. filters, toggles), include them here. +# --------------------------------------------------------------------------- + +HTMX_STATE_ELEMENTS = [ + "#config-search", # search/filter state + # "#config-filter", # future: filter dropdown + # "#config-scope", # future: scope selector +] + +HTMX_INCLUDE = ", ".join(HTMX_STATE_ELEMENTS) + scrollbar_viewport_styles = ( "scrollbar-width: none; -ms-overflow-style: none; -webkit-overflow-scrolling: touch;" @@ -224,6 +246,7 @@ def make_config_update_form() -> Callable[[str, str], Grid]: hx_put=request_url_for("/eosdash/configuration"), hx_target="#page-content", hx_swap="innerHTML", + hx_include=HTMX_INCLUDE, ), ), id=f"{config_id}-update-form", @@ -262,6 +285,7 @@ def make_config_update_value_form( .querySelector("[name='{config_id}_selected_value']") .value }}""", + hx_include=HTMX_INCLUDE, ), Select( Option("Select a value...", value="", selected=True, disabled=True), @@ -336,6 +360,7 @@ def make_config_update_list_form(available_values: list[str]) -> Callable[[str, ])].filter(v => v !== "") ) }}""", + hx_include=HTMX_INCLUDE, ), Select( Option("Select a value...", value="", selected=True, disabled=True), @@ -365,6 +390,7 @@ def make_config_update_list_form(available_values: list[str]) -> Callable[[str, ])].filter(v => v !== document.querySelector("[name='{config_id}_selected_delete_value']").value.trim()) ) }}""", + hx_include=HTMX_INCLUDE, ), Select( Option("Select a value...", value="", selected=True, disabled=True), @@ -427,6 +453,7 @@ def make_config_update_map_form( ) ) }}""", + hx_include=HTMX_INCLUDE, ), ( Select( @@ -478,6 +505,7 @@ def make_config_update_map_form( ) ) }}""", + hx_include=HTMX_INCLUDE, ), Select( Option("Select key...", value="", selected=True, disabled=True), @@ -500,11 +528,57 @@ def make_config_update_time_windows_windows_form( ) -> Callable[[str, str], Grid]: """Factory for a form that edits the windows field of a TimeWindowSequence. + Renders one collapsible row per existing window with inline edit inputs + pre-filled with the current values, a two-click delete control (trash icon + arms on first click, red confirm button on second), and an "Add window" + section at the bottom for appending new entries. + Args: - value_description: If given, a numeric value field is included in the form - and shown in the column header (e.g. "electricity_price_kwh [Amt/kWh]"). - If None, no value field is rendered. + value_description: If given, a numeric value field is included in + both the edit rows and the add section, labelled with this string + (e.g. ``"electricity_price_kwh [Amt/kWh]"``). When ``None`` no + value field is rendered. + + Returns: + A factory ``(config_name: str, value: str) -> Grid``. """ + DOW_LABELS = [ + "0 – Monday", + "1 – Tuesday", + "2 – Wednesday", + "3 – Thursday", + "4 – Friday", + "5 – Saturday", + "6 – Sunday", + ] + + def _dow_select(name: str, current: Optional[int]) -> Select: + """Render a day-of-week dropdown pre-selected to *current*.""" + return Select( + Option("— any day —", value="", selected=(current is None)), + *[ + Option(lbl, value=str(i), selected=(current == i)) + for i, lbl in enumerate(DOW_LABELS) + ], + name=name, + cls="border rounded px-2 py-1 text-sm", + ) + + def _window_summary(win: dict) -> str: + """One-line human-readable label for an existing window.""" + parts = [win.get("start_time", ""), win.get("duration", "")] + if value_description is not None: + parts.append(str(win.get("value", ""))) + dow = win.get("day_of_week") + if dow is not None: + parts.append(f"dow={dow}") + date_val = win.get("date") + if date_val: + parts.append(f"date={date_val}") + locale_val = win.get("locale") + if locale_val: + parts.append(f"locale={locale_val}") + return " | ".join(p for p in parts if p) def ConfigUpdateTimeWindowsWindowsForm(config_name: str, value: str) -> Grid: config_id = config_name.lower().replace(".", "-") @@ -515,125 +589,209 @@ def make_config_update_time_windows_windows_form( except (json.JSONDecodeError, AttributeError): current_windows = [] - DOW_LABELS = [ - "0 – Monday", - "1 – Tuesday", - "2 – Wednesday", - "3 – Thursday", - "4 – Friday", - "5 – Saturday", - "6 – Sunday", - ] + num_cols = 5 + (1 if value_description is not None else 0) - # ---- Existing windows rows ---- + # ---------------------------------------------------------------- + # Existing window rows — each is a collapsible
with + # pre-filled edit inputs and a two-click delete control. + # ---------------------------------------------------------------- window_rows = [] for idx, win in enumerate(current_windows): - start_time = win.get("start_time", "") - duration = win.get("duration", "") - dow = win.get("day_of_week") - date_val = win.get("date") - locale_val = win.get("locale") - - dow_str = f" dow={dow}" if dow is not None else "" - date_str = f" date={date_val}" if date_val else "" - locale_str = f" locale={locale_val}" if locale_val else "" - - if value_description is not None: - val = win.get("value", "") - val_str = f" | {val} {value_description}" - else: - val_str = "" - - label = f"{start_time} | {duration}{val_str}{dow_str}{date_str}{locale_str}" - + wid = f"{config_id}_w{idx}" remaining = [w for i, w in enumerate(current_windows) if i != idx] - remaining_json = json.dumps(json.dumps(remaining)) - window_rows.append( - DivHStacked( + rem_json = json.dumps(json.dumps(remaining)) + + # --- Two-click delete --- + delete_ctrl = Details( + Summary( + UkIcon( + "trash-2", cls="text-muted-foreground hover:text-destructive cursor-pointer" + ), + cls="list-none", + ), + Div( ConfigButton( UkIcon("trash-2"), + " Confirm delete", hx_put=request_url_for("/eosdash/configuration"), hx_target="#page-content", hx_swap="innerHTML", - hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {remaining_json} }}', - cls="px-2 py-1", + hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {rem_json} }}', + hx_include=HTMX_INCLUDE, + cls="px-3 py-1 text-sm bg-destructive text-destructive-foreground hover:bg-destructive/90", + ), + cls="absolute z-10 mt-1 p-2 rounded-md border bg-background shadow-md", + ), + cls="relative", + ) + + # --- Save-edit JS: build updated list with this window replaced --- + before_json = json.dumps(current_windows[:idx]) + after_json = json.dumps(current_windows[idx + 1 :]) + val_js_read = ( + f"const val = parseFloat(document.querySelector(\"[name='{wid}_value']\").value);" + if value_description is not None + else "" + ) + val_js_guard = "isNaN(val)" if value_description is not None else "false" + val_js_field = "value: val," if value_description is not None else "" + + save_button = ConfigButton( + UkIcon("save"), + " Save", + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals=f"""js:{{ + action: "update", + key: "{config_name}", + value: (() => {{ + const start = document.querySelector("[name='{wid}_start_time']").value.trim(); + const dur = document.querySelector("[name='{wid}_duration']").value.trim(); + {val_js_read} + const dowRaw = document.querySelector("[name='{wid}_dow']").value; + const date = document.querySelector("[name='{wid}_date']").value.trim(); + const locale = document.querySelector("[name='{wid}_locale']").value.trim(); + if (!start || !dur || {val_js_guard}) return {json.dumps(json.dumps(current_windows))}; + const edited = {{ + start_time: start, + duration: dur, + {val_js_field} + day_of_week: dowRaw !== "" ? parseInt(dowRaw) : null, + date: date !== "" ? date : null, + locale: locale !== "" ? locale : null, + }}; + const updated = [...{before_json}, edited, ...{after_json}]; + return JSON.stringify(updated); + }})() + }}""", + hx_include=HTMX_INCLUDE, + ) + + # --- Edit inputs pre-filled from current window --- + edit_cols = [ + Input( + value=win.get("start_time", ""), + name=f"{wid}_start_time", + placeholder="e.g. 08:00", + cls="border rounded px-2 py-1 text-sm", + ), + Input( + value=win.get("duration", ""), + name=f"{wid}_duration", + placeholder="e.g. 8 hours", + cls="border rounded px-2 py-1 text-sm", + ), + ] + if value_description is not None: + edit_cols.append( + Input( + value=str(win.get("value", "")), + name=f"{wid}_value", + type="number", + step="0.001", + cls="border rounded px-2 py-1 text-sm", + ) + ) + edit_cols += [ + _dow_select(f"{wid}_dow", win.get("day_of_week")), + Input( + value=win.get("date") or "", + name=f"{wid}_date", + placeholder="YYYY-MM-DD", + cls="border rounded px-2 py-1 text-sm", + ), + Input( + value=win.get("locale") or "", + name=f"{wid}_locale", + placeholder="e.g. de", + cls="border rounded px-2 py-1 text-sm", + ), + ] + + window_rows.append( + Details( + Summary( + DivHStacked( + delete_ctrl, + P(_window_summary(win), cls="ml-2 text-sm font-mono cursor-pointer"), + ), + cls="list-none", + ), + Grid( + Grid(*edit_cols, cols=num_cols, cls="gap-2 mt-2"), + save_button, + cols=1, + cls="gap-2 mt-1 p-2 border rounded-md bg-muted/30", ), - P(label, cls="ml-2 text-sm font-mono"), ) ) - # ---- Column headers and inputs ---- - num_cols = 5 + (1 if value_description is not None else 0) + # ---------------------------------------------------------------- + # Add new window section + # ---------------------------------------------------------------- + add_wid = f"{config_id}_new" header_cols = [ P("start_time *", cls="text-xs text-muted-foreground font-semibold"), P("duration *", cls="text-xs text-muted-foreground font-semibold"), ] - input_cols = [ + add_input_cols = [ Input( placeholder="e.g. 08:00 Europe/Berlin", - name=f"{config_id}_tw_start_time", + name=f"{add_wid}_start_time", cls="border rounded px-2 py-1 text-sm", ), Input( placeholder="e.g. 8 hours", - name=f"{config_id}_tw_duration", + name=f"{add_wid}_duration", cls="border rounded px-2 py-1 text-sm", ), ] - if value_description is not None: header_cols.append( P(f"{value_description} *", cls="text-xs text-muted-foreground font-semibold") ) - input_cols.append( + add_input_cols.append( Input( placeholder="e.g. 0.288", - name=f"{config_id}_tw_value", + name=f"{add_wid}_value", type="number", step="0.001", cls="border rounded px-2 py-1 text-sm", ) ) - header_cols += [ P("day_of_week", cls="text-xs text-muted-foreground font-semibold"), P("date (YYYY-MM-DD)", cls="text-xs text-muted-foreground font-semibold"), P("locale", cls="text-xs text-muted-foreground font-semibold"), ] - input_cols += [ - Select( - Option("— any day —", value="", selected=True), - *[Option(lbl, value=str(i)) for i, lbl in enumerate(DOW_LABELS)], - name=f"{config_id}_tw_dow", - cls="border rounded px-2 py-1 text-sm", - ), + add_input_cols += [ + _dow_select(f"{add_wid}_dow", None), Input( placeholder="e.g. 2025-12-24", - name=f"{config_id}_tw_date", + name=f"{add_wid}_date", cls="border rounded px-2 py-1 text-sm", ), Input( placeholder="e.g. de", - name=f"{config_id}_tw_locale", + name=f"{add_wid}_locale", cls="border rounded px-2 py-1 text-sm", ), ] - # ---- JS for Add button ---- current_json = json.dumps(json.dumps(current_windows)) - if value_description is not None: - val_js_read = f"const val = parseFloat(document.querySelector(\"[name='{config_id}_tw_value']\").value);" - val_js_guard = "isNaN(val)" - val_js_field = "value: val," - else: - val_js_read = "" - val_js_guard = "false" - val_js_field = "" + add_val_js_read = ( + f"const val = parseFloat(document.querySelector(\"[name='{add_wid}_value']\").value);" + if value_description is not None + else "" + ) + add_val_js_guard = "isNaN(val)" if value_description is not None else "false" + add_val_js_field = "value: val," if value_description is not None else "" add_section = Grid( Grid(*header_cols, cols=num_cols), - Grid(*input_cols, cols=num_cols), + Grid(*add_input_cols, cols=num_cols), ConfigButton( UkIcon("plus"), " Add window", @@ -644,17 +802,17 @@ def make_config_update_time_windows_windows_form( action: "update", key: "{config_name}", value: (() => {{ - const start = document.querySelector("[name='{config_id}_tw_start_time']").value.trim(); - const dur = document.querySelector("[name='{config_id}_tw_duration']").value.trim(); - {val_js_read} - const dowRaw = document.querySelector("[name='{config_id}_tw_dow']").value; - const date = document.querySelector("[name='{config_id}_tw_date']").value.trim(); - const locale = document.querySelector("[name='{config_id}_tw_locale']").value.trim(); - if (!start || !dur || {val_js_guard}) return {current_json}; + const start = document.querySelector("[name='{add_wid}_start_time']").value.trim(); + const dur = document.querySelector("[name='{add_wid}_duration']").value.trim(); + {add_val_js_read} + const dowRaw = document.querySelector("[name='{add_wid}_dow']").value; + const date = document.querySelector("[name='{add_wid}_date']").value.trim(); + const locale = document.querySelector("[name='{add_wid}_locale']").value.trim(); + if (!start || !dur || {add_val_js_guard}) return {current_json}; const newWin = {{ start_time: start, - duration: dur, - {val_js_field} + duration: dur, + {add_val_js_field} day_of_week: dowRaw !== "" ? parseInt(dowRaw) : null, date: date !== "" ? date : null, locale: locale !== "" ? locale : null, @@ -664,6 +822,7 @@ def make_config_update_time_windows_windows_form( return JSON.stringify(existing); }})() }}""", + hx_include=HTMX_INCLUDE, ), cols=1, cls="gap-2 mt-2", @@ -675,7 +834,7 @@ def make_config_update_time_windows_windows_form( *window_rows, P("Add new window", cls="text-sm font-semibold mt-3 mb-1"), P( - "* required | day_of_week: overridden by date if both set", + "* required | day_of_week overridden by date if both set", cls="text-xs text-muted-foreground mb-1", ), add_section, @@ -696,6 +855,7 @@ def ConfigCard( default: str, description: str, deprecated: Optional[Union[str, bool]], + scope: Optional[list[str]], update_error: Optional[str], update_value: Optional[str], update_open: Optional[bool], @@ -757,7 +917,14 @@ def ConfigCard( cls="list-none", ), Grid( - TextView(description), + Div( + DivHStacked( + *[Kbd(s) for s in scope], + ) + if scope + else None, + Markdown(description), + ), P(config_type), ) if not deprecated @@ -795,6 +962,23 @@ def ConfigCard( ) +def ConfigSection(title: str, *content: Any, open: bool = False) -> Details: + """Collapsible section for grouping configuration entries.""" + return Details( + Summary( + Div( + UkIcon("chevron-right", cls="transition-transform group-open:rotate-90"), + H3(title, cls="ml-2"), + cls="flex items-center gap-2 cursor-pointer", + ), + cls="list-none", + ), + Div(*content, cls="space-y-3 mt-3"), + open=open, + cls="group border rounded-lg p-2", + ) + + def DashboardHeader(title: Optional[str]) -> Div: """Creates a styled header with a title. @@ -826,6 +1010,7 @@ def DashboardFooter(*c: Any, path: str) -> Card: hx_trigger="every 5s", hx_target="#footer-content", hx_swap="innerHTML", + hx_include=HTMX_INCLUDE, ) @@ -866,6 +1051,7 @@ def DashboardTabs(dashboard_items: dict[str, str]) -> Card: hx_target="#page-content", hx_swap="innerHTML", hx_vals='js:{ "dark": window.matchMedia("(prefers-color-scheme: dark)").matches }', + hx_include=HTMX_INCLUDE, ), ) for menu, path in dashboard_items.items() diff --git a/src/akkudoktoreos/server/dash/configuration.py b/src/akkudoktoreos/server/dash/configuration.py index b8fe887b..9c39ee51 100644 --- a/src/akkudoktoreos/server/dash/configuration.py +++ b/src/akkudoktoreos/server/dash/configuration.py @@ -1,3 +1,4 @@ +import enum import json from collections.abc import Sequence from typing import Any, Dict, List, Optional, TypeVar, Union @@ -5,39 +6,30 @@ from typing import Any, Dict, List, Optional, TypeVar, Union import requests from loguru import logger from monsterui.franken import ( - H3, - H4, Card, CardTitle, - Details, Div, - DividerLine, - DivLAligned, - DivRAligned, - Form, Grid, - Input, LabelCheckboxX, - P, - Summary, - UkIcon, ) from pydantic.fields import ComputedFieldInfo, FieldInfo from pydantic_core import PydanticUndefined from akkudoktoreos.config.config import ConfigEOS from akkudoktoreos.core.pydantic import PydanticBaseModel -from akkudoktoreos.prediction.pvforecast import PVForecastPlaneSetting from akkudoktoreos.server.dash.components import ( + HTMX_INCLUDE, ConfigCard, - JsonView, - TextView, - make_config_update_list_form, - make_config_update_map_form, - make_config_update_time_windows_windows_form, - make_config_update_value_form, + ConfigSection, + Input, ) from akkudoktoreos.server.dash.context import request_url_for +from akkudoktoreos.server.dash.itemscard import ConfigItemsCard +from akkudoktoreos.server.dash.mapcard import ConfigMapCard +from akkudoktoreos.server.dash.uihints import ( + UI_HINTS, + resolve_form_factory, +) T = TypeVar("T") @@ -156,23 +148,77 @@ def get_deprecated( return getattr(subfield_info, "deprecated", None) +def get_scope( + extra: Dict[str, Any], +) -> Optional[list[str]]: + """Fetch x-scope. + + Returns the value of json_schema_extra["x-scope"] as a list of strings, or None if not set. + """ + scope = extra.get("x-scope") + if scope is None: + return None + if isinstance(scope, list): + return [str(s) for s in scope] + return [str(scope)] + + def get_default_value(field_info: Union[FieldInfo, ComputedFieldInfo], regular_field: bool) -> Any: - """Retrieve the default value of a field. + """Retrieve the default value of a field as a JSON-safe Python object. + + Handles both ``default`` and ``default_factory`` fields, and converts the + resulting value to a JSON-safe representation before returning. This + covers all non-primitive default types encountered in the EOS config + models: Pydantic model instances, lists of models, enums, ``Path`` + objects, and anything else that plain ``json.dumps`` would reject. + + For computed fields or fields with no default of any kind, a sentinel + string is returned instead. Args: - field_info (Union[FieldInfo, ComputedFieldInfo]): The field metadata from Pydantic. - regular_field (bool): Indicates if the field is a regular field. + field_info: The field metadata from Pydantic. + regular_field: ``True`` for a ``FieldInfo`` (regular field), + ``False`` for a ``ComputedFieldInfo``. Returns: - Any: The default value of the field or "N/A" if not a regular field. + A JSON-safe Python object (dict, list, str, int, float, bool, or + ``None``) representing the field default, or ``"N/A"`` when no + meaningful default exists. """ - default_value = "" - if regular_field: - if (val := field_info.default) is not PydanticUndefined: - default_value = val + import pathlib + + if not regular_field: + return "N/A" + + # Resolve the raw default — prefer plain default, fall back to factory + if field_info.default is not PydanticUndefined: + val = field_info.default + elif field_info.default_factory is not None: + try: + val = field_info.default_factory() + except Exception: + return "" else: - default_value = "N/A" - return default_value + return "" + + def _to_json_safe(v: Any) -> Any: + """Recursively convert a value to a JSON-safe type.""" + if v is None or isinstance(v, (bool, int, float, str)): + return v + if isinstance(v, PydanticBaseModel): + return v.model_dump(mode="json") + if isinstance(v, enum.Enum): + return v.value + if isinstance(v, pathlib.PurePath): + return str(v) + if isinstance(v, dict): + return {str(k): _to_json_safe(w) for k, w in v.items()} + if isinstance(v, (list, tuple, set, frozenset)): + return [_to_json_safe(item) for item in v] + # Last resort: str() — at minimum json.dumps won't crash + return str(v) + + return _to_json_safe(val) def resolve_nested_types(field_type: Any, parent_types: list[str]) -> list[tuple[Any, list[str]]]: @@ -252,6 +298,7 @@ def create_config_details( config["default"] = json.dumps(get_default_value(subfield_info, regular_field)) config["description"] = get_description(subfield_info, extra) config["deprecated"] = get_deprecated(subfield_info, extra) + config["scope"] = get_scope(extra) if isinstance(subfield_info, ComputedFieldInfo): config["read-only"] = "ro" type_description = str(subfield_info.return_type) @@ -307,193 +354,15 @@ def get_config(eos_host: str, eos_port: Union[str, int]) -> dict[str, Any]: return config -def ConfigPlanesCard( - config_name: str, - config_type: str, - read_only: str, - value: str, - default: str, - description: str, - max_planes: int, - update_error: Optional[str], - update_value: Optional[str], - update_open: Optional[bool], -) -> Card: - """Creates a styled configuration card for PV planes. +def config_matches_search(config: dict, search: str) -> bool: + if not search: + return True - This function generates a configuration card that is displayed in the UI with - various sections such as configuration name, type, description, default value, - current value, and error details. It supports both read-only and editable modes. - - Args: - config_name (str): The name of the PV planes configuration. - config_type (str): The type of the PV planes configuration. - read_only (str): Indicates if the PV planes configuration is read-only ("rw" for read-write, - any other value indicates read-only). - value (str): The current value of the PV planes configuration. - default (str): The default value of the PV planes configuration. - description (str): A description of the PV planes configuration. - max_planes (int): Maximum number of planes that can be set - update_error (Optional[str]): The error message, if any, during the update process. - update_value (Optional[str]): The value to be updated, if different from the current value. - update_open (Optional[bool]): A flag indicating whether the update section of the card - should be initially expanded. - - Returns: - Card: A styled Card component containing the PV planes configuration details. - """ - config_id = config_name.replace(".", "-") - # Remember overall planes update status - planes_update_error = update_error - planes_update_value = update_value - if not planes_update_value: - planes_update_value = value - planes_update_open = update_open - if not planes_update_open: - planes_update_open = False - # Create EOS planes configuration - eos_planes = json.loads(value) - eos_planes_config = { - "pvforecast": { - "planes": eos_planes, - }, - } - # Create cards for all planes - rows = [] - for i in range(0, max_planes): - plane_config = create_config_details( - PVForecastPlaneSetting(), - eos_planes_config, - values_prefix=["pvforecast", "planes", str(i)], - ) - plane_rows = [] - plane_update_open = False - if eos_planes and len(eos_planes) > i: - plane_value = json.dumps(eos_planes[i]) - else: - plane_value = json.dumps(None) - for config_key in sorted(plane_config.keys()): - config = plane_config[config_key] - update_error = config_update_latest.get(config["name"], {}).get("error") # type: ignore - update_value = config_update_latest.get(config["name"], {}).get("value") # type: ignore - update_open = config_update_latest.get(config["name"], {}).get("open") # type: ignore - update_form_factory = None - if update_open: - planes_update_open = True - plane_update_open = True - # Make mypy happy - should never trigger - if ( - not isinstance(update_error, (str, type(None))) - or not isinstance(update_value, (str, type(None))) - or not isinstance(update_open, (bool, type(None))) - ): - error_msg = "update_error or update_value or update_open of wrong type." - logger.error(error_msg) - raise TypeError(error_msg) - if config["name"].endswith("pvtechchoice"): - update_form_factory = make_config_update_value_form( - ["crystSi", "CIS", "CdTe", "Unknown"] - ) - elif config["name"].endswith("mountingplace"): - update_form_factory = make_config_update_value_form(["free", "building"]) - plane_rows.append( - ConfigCard( - config["name"], - config["type"], - config["read-only"], - config["value"], - config["default"], - config["description"], - config["deprecated"], - update_error, - update_value, - update_open, - update_form_factory, - ) - ) - rows.append( - Card( - Details( - Summary( - Grid( - Grid( - DivLAligned( - UkIcon(icon="play"), - H4(f"pvforecast.planes.{i}"), - ), - DivRAligned( - P(read_only), - ), - ), - JsonView(json.loads(plane_value)), - ), - cls="list-none", - ), - *plane_rows, - cls="space-y-4 gap-4", - open=plane_update_open, - ), - cls="w-full", - ) - ) - - return Card( - Details( - Summary( - Grid( - Grid( - DivLAligned( - UkIcon(icon="play"), - P(config_name), - ), - DivRAligned( - P(read_only), - ), - ), - JsonView(json.loads(value)), - ), - cls="list-none", - ), - Grid( - TextView(description), - P(config_type), - ), - # Default - Grid( - DivRAligned(P("default")), - P(default), - ) - if read_only == "rw" - else None, - # Set value - Grid( - DivRAligned(P("update")), - Grid( - Form( - Input(value="update", type="hidden", id="action"), - Input(value=config_name, type="hidden", id="key"), - Input(value=planes_update_value, type="text", id="value"), - hx_put=request_url_for("/eosdash/configuration"), - hx_target="#page-content", - hx_swap="innerHTML", - ), - ), - ) - if read_only == "rw" - else None, - # Last error - Grid( - DivRAligned(P("update error")), - TextView(planes_update_error), - ) - if planes_update_error - else None, - # Now come the single element configs - *rows, - cls="space-y-4 gap-4", - open=planes_update_open, - ), - cls="w-full", + return ( + search in config["name"].lower() + or search in config["description"].lower() + or search in config["type"].lower() + or search in config["value"].lower() ) @@ -569,6 +438,24 @@ def Configuration( # Process configuration data config_details = create_config_details(ConfigEOS, config) + # Configuration search + search_value = (data.get("search", "") if data else "").strip().lower() + + SearchBar = Card( + Input( + placeholder="Search configuration… (name, description, type)", + name="search", + value=search_value, + hx_get=request_url_for("/eosdash/configuration"), + hx_push_url="true", + hx_trigger="keyup changed delay:250ms", + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals='js:{ "dark": window.matchMedia("(prefers-color-scheme: dark)").matches }', + cls="w-full border rounded px-3 py-2", + ) + ) + ConfigMenu = Card( # CheckboxGroup to toggle config data visibility Grid( @@ -588,6 +475,7 @@ def Configuration( + '", ' + '"dark": window.matchMedia("(prefers-color-scheme: dark)").matches ' + "}", + hx_include=HTMX_INCLUDE, # lbl_cls=f"text-{solution_color[renderer]}", ) for renderer in list(config_visible.keys()) @@ -597,8 +485,6 @@ def Configuration( header=CardTitle("Choose What's Shown"), ) - rows = [] - last_category = "" # find some special configuration values try: max_planes = int(config_details["pvforecast.max_planes"]["value"]) @@ -640,16 +526,16 @@ def Configuration( logger.debug(f"devices_measurement_keys {devices_measurement_keys}") # build visual representation + sections: dict[str, list[Any]] = {} + for config_key in sorted(config_details.keys()): config = config_details[config_key] category = config["name"].split(".")[0] - if category != last_category: - rows.append(H3(category)) - rows.append(DividerLine()) - last_category = category + update_error = config_update_latest.get(config["name"], {}).get("error") update_value = config_update_latest.get(config["name"], {}).get("value") update_open = config_update_latest.get(config["name"], {}).get("open") + # Make mypy happy - should never trigger if ( not isinstance(update_error, (str, type(None))) @@ -659,97 +545,79 @@ def Configuration( error_msg = "update_error or update_value or update_open of wrong type." logger.error(error_msg) raise TypeError(error_msg) + if ( + # Do not display read only values not config_visible["config-visible-read-only"]["visible"] and config["read-only"] != "rw" ): - # Do not display read only values continue - if ( - config["type"] - == "Optional[list[akkudoktoreos.prediction.pvforecast.PVForecastPlaneSetting]]" - and not config["deprecated"] - ): - # Special configuration for PV planes - rows.append( - ConfigPlanesCard( - config["name"], - config["type"], - config["read-only"], - config["value"], - config["default"], - config["description"], - max_planes, - update_error, - update_value, - update_open, - ) + + if not config_matches_search(config, search_value): + # Search value given but does not match + continue + + hint = UI_HINTS.get(config["name"]) + + if hint and hint.form == "items" and not config["deprecated"]: + card = ConfigItemsCard( + config=config, + hint=hint, + config_details=config_details, + config_update_latest=config_update_latest, + create_config_details=create_config_details, + ) + elif hint and hint.form == "map_items" and not config["deprecated"]: + card = ConfigMapCard( + config=config, + hint=hint, + config_details=config_details, + config_update_latest=config_update_latest, + create_config_details=create_config_details, ) elif not config["deprecated"]: - update_form_factory = None - if config["name"].endswith(".provider"): - # Special configuration for prediction provider setting - try: - provider_ids = json.loads(config_details[config["name"] + "s"]["value"]) - except Exception: - provider_ids = [] - if config["type"].startswith("Optional[list"): - update_form_factory = make_config_update_list_form(provider_ids) - else: - provider_ids.append("None") - update_form_factory = make_config_update_value_form(provider_ids) - elif config["name"].startswith("adapter.homeassistant.config_entity_ids"): - # Home Assistant adapter config entities - update_form_factory = make_config_update_map_form(None, homeassistant_entity_ids) - elif config["name"].startswith("adapter.homeassistant.load_emr_entity_ids"): - # Home Assistant adapter load energy meter readings entities - update_form_factory = make_config_update_list_form(homeassistant_entity_ids) - elif config["name"].startswith("adapter.homeassistant.grid_export_emr_entity_ids"): - # Home Assistant adapter grid export energy meter readings entities - update_form_factory = make_config_update_list_form(homeassistant_entity_ids) - elif config["name"].startswith("adapter.homeassistant.grid_import_emr_entity_ids"): - # Home Assistant adapter grid import energy meter readings entities - update_form_factory = make_config_update_list_form(homeassistant_entity_ids) - elif config["name"].startswith("adapter.homeassistant.pv_production_emr_entity_ids"): - # Home Assistant adapter pv energy meter readings entities - update_form_factory = make_config_update_list_form(homeassistant_entity_ids) - elif config["name"].startswith("adapter.homeassistant.device_measurement_entity_ids"): - # Home Assistant adapter device measurement entities - update_form_factory = make_config_update_map_form( - devices_measurement_keys, homeassistant_entity_ids - ) - elif config["name"].startswith("adapter.homeassistant.device_instruction_entity_ids"): - # Home Assistant adapter device instruction entities - update_form_factory = make_config_update_list_form( - eos_device_instruction_entity_ids - ) - elif config["name"].startswith("adapter.homeassistant.solution_entity_ids"): - # Home Assistant adapter optimization solution entities - update_form_factory = make_config_update_list_form(eos_solution_entity_ids) - elif config["name"].startswith("ems.mode"): - # Energy management mode - update_form_factory = make_config_update_value_form( - ["OPTIMIZATION", "PREDICTION", "DISABLED"] - ) - elif config["name"].endswith("elecpricefixed.time_windows.windows"): - update_form_factory = make_config_update_time_windows_windows_form( - value_description="electricity_price_kwh [Amt/kWh]" - ) + update_form_factory = resolve_form_factory(hint, config_details) if hint else None + card = ConfigCard( + config["name"], + config["type"], + config["read-only"], + config["value"], + config["default"], + config["description"], + config["deprecated"], + config["scope"], + update_error, + update_value, + update_open, + update_form_factory, + ) + else: + continue - rows.append( - ConfigCard( - config["name"], - config["type"], - config["read-only"], - config["value"], - config["default"], - config["description"], - config["deprecated"], - update_error, - update_value, - update_open, - update_form_factory, - ) + sections.setdefault(category, []).append(card) + + section_components = [] + + for category in sorted(sections.keys()): + cards = sections[category] + + # Open if searching OR if last update was here + open_section = bool(search_value) + + if not open_section: + open_section = any( + config_update_latest.get(c["name"], {}).get("open") + for c in config_details.values() + if c["name"].startswith(category) ) - return Div(ConfigMenu, *rows, cls="space-y-3") + section_components.append(ConfigSection(category, *cards, open=open_section)) + + return Div( + Grid( + ConfigMenu, + SearchBar, + ), + *section_components, + cls="space-y-4", + ) diff --git a/src/akkudoktoreos/server/dash/itemscard.py b/src/akkudoktoreos/server/dash/itemscard.py new file mode 100644 index 00000000..9afe1ffe --- /dev/null +++ b/src/akkudoktoreos/server/dash/itemscard.py @@ -0,0 +1,555 @@ +"""Generic expandable list-of-sub-model configuration card for EOSdash. + +This module provides `ConfigItemsCard`, a reusable FastHTML/MonsterUI +card component that renders any ``list[PydanticSubModel]`` config field as a +collapsible outer card containing one collapsible inner card per list item. + +It is intentionally free of imports from ``configuration.py`` to avoid +circular dependencies. The one runtime dependency on +``create_config_details`` is injected by the caller. + +Typical usage in ``configuration.py``:: + + from akkudoktoreos.server.dash.itemscard import ConfigItemsCard + + hint = UI_HINTS.get(config["name"]) + if hint and hint.form == "items" and not config["deprecated"]: + rows.append( + ConfigItemsCard( + config=config, + hint=hint, + config_details=config_details, + config_update_latest=config_update_latest, + create_config_details=create_config_details, + ) + ) +""" + +import json +from typing import Any, Callable, Optional + +from loguru import logger +from monsterui.franken import ( + H4, + Card, + Details, + Div, + DivHStacked, + DivLAligned, + DivRAligned, + Form, + Grid, + Input, + Kbd, + P, + Summary, + UkIcon, +) + +from akkudoktoreos.server.dash.carditems import ( + item_model_defaults, + required_field_inputs, +) +from akkudoktoreos.server.dash.components import ( + ConfigButton, + ConfigCard, + JsonView, + UpdateError, +) +from akkudoktoreos.server.dash.context import request_url_for +from akkudoktoreos.server.dash.markdown import Markdown +from akkudoktoreos.server.dash.uihints import ( + UiHint, + hint_for_indexed_field, + resolve_form_factory, + resolve_item_model, +) + +# --------------------------------------------------------------------------- +# Internal helpers +# --------------------------------------------------------------------------- + + +def _add_control( + config_name: str, + item_model: Any, + items_list: list, + read_only: str, +) -> Any: + """Build the 'Add item' control for the outer card header. + + When the item model can be fully defaulted, this is a one-click button + that appends immediately. When required fields have no default (e.g. + `consumption_wh`/`duration_h` on `HomeApplianceCommonSettings`), clicking + would otherwise submit an invalid item, so instead this renders a small + inline form that collects those values first and only builds the PUT + payload once every required input is non-empty (enforced via HTML + `required`). + """ + if read_only != "rw": + return None + + new_item_defaults, required_missing = item_model_defaults(item_model) + + if not required_missing: + appended_json = json.dumps(json.dumps(items_list + [new_item_defaults])) + return ConfigButton( + UkIcon("plus"), + " Add item", + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {appended_json} }}', + cls="ml-4 px-3 py-1 text-sm", + ) + + id_prefix = f"new-item-{config_name}" + inputs, js_pairs = required_field_inputs(item_model, required_missing, id_prefix) + + defaults_json = json.dumps(new_item_defaults) + items_json = json.dumps(items_list) + build_value_expr = ( + "(function(){" + f"var base = {defaults_json};" + f"var extra = {{ {', '.join(js_pairs)} }};" + f"var items = {items_json};" + "return JSON.stringify(items.concat([Object.assign({}, base, extra)]));" + "})()" + ) + + return Details( + Summary( + UkIcon("plus"), + " Add item", + cls="list-none cursor-pointer inline-flex items-center gap-1 ml-4", + ), + Form( + *inputs, + ConfigButton( + "Create", + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {build_value_expr} }}', + cls="mt-2 px-3 py-1 text-sm", + ), + cls="absolute z-10 mt-1 p-3 rounded-md border bg-background shadow-md space-y-2", + ), + cls="relative", + ) + + +def _delete_control(config_name: str, items_list: list, index: int) -> Details: + """Build the two-click delete control for a single inner item card header. + + The first click opens a ``
`` panel revealing a red "Confirm + delete" button. Clicking outside collapses it. The second click + (on the confirm button) submits an ``hx_put`` with the list minus the + given index. + + Args: + config_name: Dotted config key name, e.g. ``"pvforecast.planes"``. + items_list: The current full list of item dicts. + index: The zero-based index of the item to delete. + + Returns: + A ``Details`` component implementing the two-click confirm pattern. + """ + remaining_json = json.dumps(json.dumps([w for j, w in enumerate(items_list) if j != index])) + return Details( + Summary( + UkIcon("trash-2", cls="text-muted-foreground hover:text-destructive cursor-pointer"), + cls="list-none", + ), + Div( + ConfigButton( + UkIcon("trash-2"), + " Confirm delete", + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {remaining_json} }}', + cls="px-3 py-1 text-sm bg-destructive text-destructive-foreground hover:bg-destructive/90", + ), + cls="absolute z-10 mt-1 p-2 rounded-md border bg-background shadow-md", + ), + cls="relative", + ) + + +def _inner_card( + config_name: str, + item_path: str, + path_parts: list[str], + index: int, + item_value: str, + is_empty: bool, + read_only: str, + item_rows: list, + item_update_open: bool, + delete_control: Optional[Details], +) -> Card: + """Render a single collapsible inner card for one list item. + + Args: + config_name: Dotted config key of the parent list field. + item_path: Dotted path prefix for this item type, e.g. + ``"pvforecast.planes"``. + path_parts: ``item_path`` split on ``"."``. + index: Zero-based position of this item in the list. + item_value: JSON-encoded current value of this item. + is_empty: ``True`` when the item dict is falsy (empty or ``None``). + read_only: ``"rw"`` or ``"ro"`` inherited from the parent field. + item_rows: Pre-built list of ``ConfigCard`` children for this item. + item_update_open: Whether this card should start expanded. + delete_control: The two-click delete ``Details`` widget, or ``None`` + for read-only fields. + + Returns: + A ``Card`` component for this item slot. + """ + return Card( + Details( + Summary( + Grid( + Grid( + DivLAligned( + UkIcon(icon="play"), + H4( + f"{item_path}.{index}", + cls="text-muted-foreground" if is_empty else "", + ), + delete_control, + ), + DivRAligned( + P( + "empty" if is_empty else read_only, + cls="text-xs text-muted-foreground" if is_empty else "", + ), + ), + ), + JsonView(json.loads(item_value)), + ), + cls="list-none", + ), + *item_rows, + cls="space-y-4 gap-4", + open=item_update_open, + ), + cls=f"w-full {'opacity-60' if is_empty else ''}", + ) + + +def _outer_card( + config_name: str, + config_type: str, + read_only: str, + value: str, + default: str, + description: str, + scope: Optional[list[str]], + num_items: int, + add_button: Any, + items_update_value: str, + items_update_error: Optional[str], + items_update_open: bool, + rows: list, +) -> Card: + """Render the outer collapsible card for the whole list field. + + Args: + config_name: Dotted config key name. + config_type: Human-readable type string from config details. + read_only: ``"rw"`` or ``"ro"``. + value: JSON-encoded current list value. + default: JSON-encoded default value. + description: Field description text. + num_items: Current number of items, shown as a badge. + add_button: The "Add item" control from ``_add_control`` — a + ``ConfigButton`` when the item model is fully defaulted, a + ``Details``/``Form`` combo when required fields must be + collected first, or ``None`` for read-only fields. + items_update_value: Value to pre-fill the fallback text input. + items_update_error: Error string from the last failed update, or + ``None``. + items_update_open: Whether the outer card starts expanded. + rows: Pre-built list of inner ``Card`` components. + + Returns: + The outer ``Card`` component. + """ + return Card( + Details( + Summary( + Grid( + Grid( + DivLAligned( + UkIcon(icon="play"), + P(config_name), + P( + f"{num_items} item{'s' if num_items != 1 else ''}", + cls="ml-2 text-xs text-muted-foreground", + ), + add_button, + ), + DivRAligned(P(read_only)), + ), + JsonView(json.loads(value)), + ), + cls="list-none", + ), + Grid( + Div( + DivHStacked(*[Kbd(s) for s in scope]) if scope else None, + Markdown(description), + ), + P(config_type), + ), + # Default value row + Grid( + DivRAligned(P("default")), + P(default), + ) + if read_only == "rw" + else None, + # Raw JSON fallback update form + Grid( + DivRAligned(P("update")), + Grid( + Form( + Input(value="update", type="hidden", id="action"), + Input(value=config_name, type="hidden", id="key"), + Input(value=items_update_value, type="text", id="value"), + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + ), + ), + ) + if read_only == "rw" + else None, + # Last update error + Grid( + DivRAligned(P("update error")), + UpdateError(items_update_error), + ) + if items_update_error + else None, + # Per-item inner cards + *rows, + cls="space-y-4 gap-4", + open=items_update_open, + ), + cls="w-full", + ) + + +# --------------------------------------------------------------------------- +# Public API +# --------------------------------------------------------------------------- + + +def ConfigItemsCard( + config: dict, + hint: UiHint, + config_details: dict[str, dict], + config_update_latest: dict[str, dict], + create_config_details: Callable, +) -> Card: + """Creates a styled configuration card for a list of Pydantic sub-model items. + + Renders a collapsible outer card representing the list field as a whole, + containing one collapsible inner card per item in the list. Each inner + card expands into individual ``ConfigCard`` rows for every field of the + item's Pydantic sub-model. + + The list length is driven entirely by user interaction — there is no fixed + maximum. + + An "Add item" control in the outer card header creates a new item + pre-filled with the sub-model's Pydantic field defaults. When every + field has a default, this is a one-click button that appends and PUTs + immediately. When the sub-model has fields with no default (e.g. + ``consumption_wh``/``duration_h`` on ``HomeApplianceCommonSettings``), + the control instead expands into a small inline form that collects + those required values first — the PUT is only built, via HTML + ``required`` inputs, once every missing field is filled in, so an + invalid item is never persisted. Each inner card header carries a + trash icon that arms on first click (showing a red "Confirm delete" + button via a ``
`` toggle) and deletes on the second click, + with no modal required. + Per-item field forms are resolved via ``hint_for_indexed_field`` using the + parent hint's ``item_path``, so per-field UI customisation (dropdowns, + selects, etc.) is driven entirely by ``UI_HINTS`` entries — no hard-coded + field-name checks are needed here. + + The outer card always includes a plain-text fallback update form for the + whole list value so that recovery from a validation error is always + possible. + + Args: + config: A single entry from the ``config_details`` dict produced by + ``create_config_details()``. Must contain the keys ``"name"``, + ``"type"``, ``"read-only"``, ``"value"``, ``"default"``, + ``"description"``, ``"deprecated"``, and ``"scope"``. + hint: The ``UiHint`` for this field. Must have ``form == "items"`` + and valid ``item_model`` (resolved via ``resolve_item_model``) and + ``item_path`` values. ``max_items_from`` is ignored — the list + grows and shrinks freely via Add / Delete. + config_details: The full config detail dict for the current page + render, used to look up per-item field update state. + config_update_latest: The module-level dict that tracks the most + recent update attempt for each config key, with sub-keys + ``"error"``, ``"value"``, and ``"open"``. + create_config_details: The ``create_config_details`` callable from + ``configuration.py``, injected to avoid a circular import. + Signature: ``(model, values, values_prefix) -> dict[str, dict]``. + + Returns: + Card: A fully rendered outer ``Card`` component containing the list + summary with item count and an "Add item" control (a one-click + button, or an inline required-fields form — see above), description, + default value row, a raw-JSON fallback update form, an optional + error row, and one collapsible inner ``Card`` per existing item each + with a two-click delete control. + + Raises: + TypeError: If ``update_error``, ``update_value``, or ``update_open`` + retrieved from ``config_update_latest`` are not of the expected + types (``str | None``, ``str | None``, ``bool | None`` + respectively). This should never trigger in normal operation but + is checked explicitly to satisfy static analysis. + + Example: + Typical call from inside the ``Configuration()`` render loop:: + + from akkudoktoreos.server.dash.itemscard import ConfigItemsCard + + hint = UI_HINTS.get(config["name"]) + if hint and hint.form == "items" and not config["deprecated"]: + rows.append( + ConfigItemsCard( + config=config, + hint=hint, + config_details=config_details, + config_update_latest=config_update_latest, + create_config_details=create_config_details, + ) + ) + """ + config_name = config["name"] + config_type = config["type"] + read_only = config["read-only"] + value = config["value"] + default = config["default"] + description = config["description"] + + item_model = resolve_item_model(hint) + item_path = hint.item_path # e.g. "pvforecast.planes" + if item_path is None: + raise ValueError(f"Hint needs item_path to be listed. Got {hint}") + path_parts = item_path.split(".") # e.g. ["pvforecast", "planes"] + + items_list = json.loads(value) or [] + num_items = len(items_list) + + # Synthetic wrapper dict so create_config_details can traverse the value: + # e.g. {"pvforecast": {"planes": [...]}} + wrapped = json.loads(value) + for key in reversed(path_parts): + wrapped = {key: wrapped} + + # Outer card update state — resolved once before the inner loop + items_update_error = config_update_latest.get(config_name, {}).get("error") + items_update_value = config_update_latest.get(config_name, {}).get("value") or value + items_update_open = config_update_latest.get(config_name, {}).get("open") or False + + # Add button. + # One-click append when the item model is fully defaulted, otherwise an inline form that + # collects required fields before the PUT fires (see _add_control / _item_model_defaults + # docstrings). + add_button = _add_control(config_name, item_model, items_list, read_only) + + # Build inner cards + rows = [] + for i in range(num_items): + item_config = create_config_details( + item_model, + wrapped, + values_prefix=path_parts + [str(i)], + ) + item_rows = [] + item_update_open = False + item_value = json.dumps(items_list[i]) if items_list[i] is not None else json.dumps(None) + is_empty = not items_list[i] + + for field_key in sorted(item_config.keys()): + sub = item_config[field_key] + update_error = config_update_latest.get(sub["name"], {}).get("error") + update_value = config_update_latest.get(sub["name"], {}).get("value") + update_open = config_update_latest.get(sub["name"], {}).get("open") + if update_open: + items_update_open = True # bubble up to outer card + item_update_open = True + # Make mypy happy — should never trigger + if ( + not isinstance(update_error, (str, type(None))) + or not isinstance(update_value, (str, type(None))) + or not isinstance(update_open, (bool, type(None))) + ): + error_msg = "update_error or update_value or update_open of wrong type." + logger.error(error_msg) + raise TypeError(error_msg) + sub_hint = hint_for_indexed_field(sub["name"], item_path) + update_form_factory = ( + resolve_form_factory(sub_hint, config_details) if sub_hint else None + ) + item_rows.append( + ConfigCard( + sub["name"], + sub["type"], + sub["read-only"], + sub["value"], + sub["default"], + sub["description"], + sub["deprecated"], + sub["scope"], + update_error, + update_value, + update_open, + update_form_factory, + ) + ) + + rows.append( + _inner_card( + config_name=config_name, + item_path=item_path, + path_parts=path_parts, + index=i, + item_value=item_value, + is_empty=is_empty, + read_only=read_only, + item_rows=item_rows, + item_update_open=item_update_open, + delete_control=_delete_control(config_name, items_list, i) + if read_only == "rw" + else None, + ) + ) + + return _outer_card( + config_name=config_name, + config_type=config_type, + read_only=read_only, + value=value, + default=default, + description=description, + scope=config.get("scope"), + num_items=num_items, + add_button=add_button, + items_update_value=items_update_value, + items_update_error=items_update_error, + items_update_open=items_update_open, + rows=rows, + ) diff --git a/src/akkudoktoreos/server/dash/mapcard.py b/src/akkudoktoreos/server/dash/mapcard.py new file mode 100644 index 00000000..06081b18 --- /dev/null +++ b/src/akkudoktoreos/server/dash/mapcard.py @@ -0,0 +1,570 @@ +"""Generic expandable map-of-sub-model configuration card for EOSdash. + +This module provides `ConfigMapCard`, a reusable FastHTML/MonsterUI +card component that renders any ``dict[str, PydanticSubModel]`` config field +as a collapsible outer card containing one collapsible inner card per map +entry, keyed by a user-supplied string name. + +It is intentionally free of imports from ``configuration.py`` to avoid +circular dependencies. The one runtime dependency on +``create_config_details`` is injected by the caller. + +The structure mirrors ``itemscard.py`` with these key differences: + +- The stored value is ``dict[str, dict]`` rather than ``list[dict]``. +- The "Add entry" control includes a text input for the key name. +- Delete removes by key rather than by index. +- Inner card headers display the string key instead of a numeric index. +- ``create_config_details`` is called with the string key as the final + ``values_prefix`` segment. + +Typical usage in ``configuration.py``:: + + from akkudoktoreos.server.dash.mapcard import ConfigMapCard + + hint = UI_HINTS.get(config["name"]) + if hint and hint.form == "map_items" and not config["deprecated"]: + rows.append( + ConfigMapCard( + config=config, + hint=hint, + config_details=config_details, + config_update_latest=config_update_latest, + create_config_details=create_config_details, + ) + ) +""" + +import json +from typing import Any, Callable, Optional + +from loguru import logger +from monsterui.franken import ( + H4, + Card, + Details, + Div, + DivHStacked, + DivLAligned, + DivRAligned, + Form, + Grid, + Input, + Kbd, + P, + Summary, + UkIcon, +) + +from akkudoktoreos.server.dash.carditems import ( + item_model_defaults, + required_field_inputs, +) +from akkudoktoreos.server.dash.components import ( + ConfigButton, + ConfigCard, + JsonView, + UpdateError, +) +from akkudoktoreos.server.dash.context import request_url_for +from akkudoktoreos.server.dash.markdown import Markdown +from akkudoktoreos.server.dash.uihints import ( + UiHint, + hint_for_indexed_field, + resolve_form_factory, + resolve_item_model, +) + +# --------------------------------------------------------------------------- +# Internal helpers +# --------------------------------------------------------------------------- + + +def _add_control( + config_name: str, + items_map: dict, + item_model: Any, + config_id: str, + read_only: str, +) -> Any: + """Build the "Add entry" control. + + Always includes a text input for the new key name. When the item model + can be fully defaulted, that's the only input needed — clicking "Add + entry" reads the key and submits the map with the new key set to the + model defaults. When required fields have no default (e.g. + `consumption_wh`/`duration_h` on `HomeApplianceCommonSettings`), the + control also renders inputs for those fields, all wrapped in a form so + HTML `required` blocks submission until the key and every required + field are filled in — otherwise clicking "Add entry" would persist an + entry that fails the model's own validation. + + If the typed key already exists the existing entry is overwritten — this + is intentional and allows renaming-by-copy when combined with delete. + + Args: + config_name: Dotted config key name. + items_map: The current map, used as the base for the JS merge. + item_model: The Pydantic model class or instance for one map entry. + config_id: CSS-safe version of ``config_name`` (dots replaced with + hyphens), used to scope element ids and the key input's name. + + Returns: + A ``Form`` containing the key input, any required-field inputs, and + the "Add entry" button. + """ + new_entry_defaults, required_missing = item_model_defaults(item_model) + + id_prefix = f"{config_id}-new-entry" + inputs, js_pairs = required_field_inputs(item_model, required_missing, id_prefix) + extra_js = f"{{ {', '.join(js_pairs)} }}" if js_pairs else "{}" + + current_json = json.dumps(items_map) + defaults_json = json.dumps(new_entry_defaults) + + build_value_expr = f"""(() => {{ + const k = document.querySelector("[name='{config_id}_new_key']").value.trim(); + if (!k) return {json.dumps(json.dumps(items_map))}; + const defaults = {defaults_json}; + const extra = {extra_js}; + Object.assign(defaults, extra); + if ('device_id' in defaults) defaults.device_id = k; + const updated = Object.assign({{}}, {current_json}, {{ [k]: defaults }}); + return JSON.stringify(updated); + }})()""" + + return Form( + Grid( + Input( + placeholder="Entry name / key", + name=f"{config_id}_new_key", + id=f"{config_id}-new-key", + required=True, + cls="border rounded px-3 py-2 text-sm", + ), + *inputs, + cols=2, + cls="gap-2", + ), + ConfigButton( + UkIcon("plus"), + " Add entry", + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {build_value_expr} }}', + cls="mt-2", + ), + cls="space-y-2 mt-3", + ) + + +def _delete_control(config_name: str, items_map: dict, key: str) -> Details: + """Build the two-click delete control for a single inner entry card header. + + The first click opens a ``
`` panel revealing a red "Confirm + delete" button. Clicking outside collapses it. The second click submits + an ``hx_put`` with the map minus the given key. + + Args: + config_name: Dotted config key name, e.g. ``"devices.batteries"``. + items_map: The current full map of entries. + key: The string key of the entry to delete. + + Returns: + A ``Details`` component implementing the two-click confirm pattern. + """ + remaining = {k: v for k, v in items_map.items() if k != key} + remaining_json = json.dumps(json.dumps(remaining)) + return Details( + Summary( + UkIcon("trash-2", cls="text-muted-foreground hover:text-destructive cursor-pointer"), + cls="list-none", + ), + Div( + ConfigButton( + UkIcon("trash-2"), + " Confirm delete", + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + hx_vals=f'js:{{ action: "update", key: "{config_name}", value: {remaining_json} }}', + cls="px-3 py-1 text-sm bg-destructive text-destructive-foreground hover:bg-destructive/90", + ), + cls="absolute z-10 mt-1 p-2 rounded-md border bg-background shadow-md", + ), + cls="relative", + ) + + +def _inner_card( + config_name: str, + item_path: str, + key: str, + item_value: str, + is_empty: bool, + read_only: str, + item_rows: list, + item_update_open: bool, + delete_control: Optional[Details], +) -> Card: + """Render a single collapsible inner card for one map entry. + + Args: + config_name: Dotted config key of the parent map field. + item_path: Dotted path prefix for this entry type, e.g. + ``"devices.batteries"``. + key: The string key identifying this entry in the map. + item_value: JSON-encoded current value of this entry. + is_empty: ``True`` when the entry dict is falsy (empty or ``None``). + read_only: ``"rw"`` or ``"ro"`` inherited from the parent field. + item_rows: Pre-built list of ``ConfigCard`` children for this entry. + item_update_open: Whether this card should start expanded. + delete_control: The two-click delete ``Details`` widget, or ``None`` + for read-only fields. + + Returns: + A ``Card`` component for this map entry. + """ + return Card( + Details( + Summary( + Grid( + Grid( + DivLAligned( + UkIcon(icon="play"), + H4( + f"{item_path}.{key}", + cls="text-muted-foreground" if is_empty else "", + ), + delete_control, + ), + DivRAligned( + P( + "empty" if is_empty else read_only, + cls="text-xs text-muted-foreground" if is_empty else "", + ), + ), + ), + JsonView(json.loads(item_value)), + ), + cls="list-none", + ), + *item_rows, + cls="space-y-4 gap-4", + open=item_update_open, + ), + cls=f"w-full {'opacity-60' if is_empty else ''}", + ) + + +def _outer_card( + config_name: str, + config_type: str, + read_only: str, + value: str, + default: str, + description: str, + scope: Optional[list[str]], + num_entries: int, + items_update_value: str, + items_update_error: Optional[str], + items_update_open: bool, + rows: list, + add_control: Optional[Grid], +) -> Card: + """Render the outer collapsible card for the whole map field. + + Args: + config_name: Dotted config key name. + config_type: Human-readable type string from config details. + read_only: ``"rw"`` or ``"ro"``. + value: JSON-encoded current map value. + default: JSON-encoded default value. + description: Field description text. + num_entries: Current number of entries, shown as a badge. + items_update_value: Value to pre-fill the fallback text input. + items_update_error: Error string from the last failed update, or + ``None``. + items_update_open: Whether the outer card starts expanded. + rows: Pre-built list of inner ``Card`` components. + add_control: The "Add entry" ``Grid`` widget, or ``None`` for + read-only fields. + + Returns: + The outer ``Card`` component. + """ + return Card( + Details( + Summary( + Grid( + Grid( + DivLAligned( + UkIcon(icon="play"), + P(config_name), + P( + f"{num_entries} entr{'ies' if num_entries != 1 else 'y'}", + cls="ml-2 text-xs text-muted-foreground", + ), + ), + DivRAligned(P(read_only)), + ), + JsonView(json.loads(value)), + ), + cls="list-none", + ), + # Add entry control below summary + add_control, + Grid( + Div( + DivHStacked(*[Kbd(s) for s in scope]) if scope else None, + Markdown(description), + ), + P(config_type), + ), + # Default value row + Grid( + DivRAligned(P("default")), + P(default), + ) + if read_only == "rw" + else None, + # Raw JSON fallback update form + Grid( + DivRAligned(P("update")), + Grid( + Form( + Input(value="update", type="hidden", id="action"), + Input(value=config_name, type="hidden", id="key"), + Input(value=items_update_value, type="text", id="value"), + hx_put=request_url_for("/eosdash/configuration"), + hx_target="#page-content", + hx_swap="innerHTML", + ), + ), + ) + if read_only == "rw" + else None, + # Last update error + Grid( + DivRAligned(P("update error")), + UpdateError(items_update_error), + ) + if items_update_error + else None, + # Per-entry inner cards + *rows, + cls="space-y-4 gap-4", + open=items_update_open, + ), + cls="w-full", + ) + + +# --------------------------------------------------------------------------- +# Public API +# --------------------------------------------------------------------------- + + +def ConfigMapCard( + config: dict, + hint: UiHint, + config_details: dict[str, dict], + config_update_latest: dict[str, dict], + create_config_details: Callable, +) -> Card: + """Creates a styled configuration card for a map of Pydantic sub-model entries. + + Renders a collapsible outer card representing the map field as a whole, + containing one collapsible inner card per map entry keyed by a string + name. Each inner card expands into individual ``ConfigCard`` rows for + every field of the entry's Pydantic sub-model. + + The map contents are driven entirely by user interaction. An "Add entry" + control at the bottom of the outer card accepts a key name and appends a + new entry pre-filled with the sub-model's Pydantic field defaults. Each + inner card header carries a trash icon that arms on first click (showing + a red "Confirm delete" button via a ``
`` toggle) and deletes on + the second click, with no modal required. + + Per-entry field forms are resolved via ``hint_for_indexed_field`` using + the parent hint's ``item_path``, so per-field UI customisation + (dropdowns, selects, etc.) is driven entirely by ``UI_HINTS`` entries — + no hard-coded field-name checks are needed here. + + The outer card always includes a plain-text fallback update form for the + whole map value so that recovery from a validation error is always + possible. + + Args: + config: A single entry from the ``config_details`` dict produced by + ``create_config_details()``. Must contain the keys ``"name"``, + ``"type"``, ``"read-only"``, ``"value"``, ``"default"``, + ``"description"``, ``"deprecated"``, and ``"scope"``. + hint: The ``UiHint`` for this field. Must have + ``form == "map_items"`` and valid ``item_model`` (resolved via + ``resolve_item_model``) and ``item_path`` values. + config_details: The full config detail dict for the current page + render, used to look up per-entry field update state. + config_update_latest: The module-level dict that tracks the most + recent update attempt for each config key, with sub-keys + ``"error"``, ``"value"``, and ``"open"``. + create_config_details: The ``create_config_details`` callable from + ``configuration.py``, injected to avoid a circular import. + Signature: ``(model, values, values_prefix) -> dict[str, dict]``. + + Returns: + Card: A fully rendered outer ``Card`` component containing the map + summary with entry count, description, default value row, a raw-JSON + fallback update form, an optional error row, one collapsible inner + ``Card`` per existing entry each with a two-click delete control, and + an "Add entry" control at the bottom. + + Raises: + TypeError: If ``update_error``, ``update_value``, or ``update_open`` + retrieved from ``config_update_latest`` are not of the expected + types (``str | None``, ``str | None``, ``bool | None`` + respectively). This should never trigger in normal operation but + is checked explicitly to satisfy static analysis. + + Example: + Typical call from inside the ``Configuration()`` render loop:: + + from akkudoktoreos.server.dash.mapcard import ConfigMapCard + + hint = UI_HINTS.get(config["name"]) + if hint and hint.form == "map_items" and not config["deprecated"]: + rows.append( + ConfigMapCard( + config=config, + hint=hint, + config_details=config_details, + config_update_latest=config_update_latest, + create_config_details=create_config_details, + ) + ) + """ + config_name = config["name"] + config_type = config["type"] + read_only = config["read-only"] + value = config["value"] + default = config["default"] + description = config["description"] + config_id = config_name.lower().replace(".", "-") + + item_model = resolve_item_model(hint) + item_path = hint.item_path # e.g. "devices.batteries" + if item_path is None: + raise ValueError(f"Hint needs item_path to be mapped. Got {hint}") + path_parts = item_path.split(".") # e.g. ["devices", "batteries"] + + items_map = json.loads(value) or {} + num_entries = len(items_map) + + # Outer card update state — resolved once before the inner loop + items_update_error = config_update_latest.get(config_name, {}).get("error") + items_update_value = config_update_latest.get(config_name, {}).get("value") or value + items_update_open = config_update_latest.get(config_name, {}).get("open") or False + + # Add entry control (key input + button) shown at the bottom of the card. + # One-click append when the item model is fully defaulted, otherwise an inline form that + # collects required fields before the PUT fires (see _add_control / _item_model_defaults + # docstrings). + add_control = _add_control( + config_name=config_name, + items_map=items_map, + item_model=item_model, + config_id=config_id, + read_only=read_only, + ) + + # Build inner cards — one per map key, sorted for stable ordering + rows = [] + for key in sorted(items_map.keys()): + entry = items_map[key] + + # Synthetic wrapper: e.g. {"devices": {"batteries": {"bat1": {...}}}} + wrapped = {key: entry} + for part in reversed(path_parts): + wrapped = {part: wrapped} + + item_config = create_config_details( + item_model, + wrapped, + values_prefix=path_parts + [key], + ) + + item_rows = [] + item_update_open = False + item_value = json.dumps(entry) if entry is not None else json.dumps(None) + is_empty = not entry + + for field_key in sorted(item_config.keys()): + sub = item_config[field_key] + update_error = config_update_latest.get(sub["name"], {}).get("error") + update_value = config_update_latest.get(sub["name"], {}).get("value") + update_open = config_update_latest.get(sub["name"], {}).get("open") + if update_open: + items_update_open = True # bubble up to outer card + item_update_open = True + # Make mypy happy — should never trigger + if ( + not isinstance(update_error, (str, type(None))) + or not isinstance(update_value, (str, type(None))) + or not isinstance(update_open, (bool, type(None))) + ): + error_msg = "update_error or update_value or update_open of wrong type." + logger.error(error_msg) + raise TypeError(error_msg) + sub_hint = hint_for_indexed_field(sub["name"], item_path) + update_form_factory = ( + resolve_form_factory(sub_hint, config_details) if sub_hint else None + ) + item_rows.append( + ConfigCard( + sub["name"], + sub["type"], + sub["read-only"], + sub["value"], + sub["default"], + sub["description"], + sub["deprecated"], + sub["scope"], + update_error, + update_value, + update_open, + update_form_factory, + ) + ) + + rows.append( + _inner_card( + config_name=config_name, + item_path=item_path, + key=key, + item_value=item_value, + is_empty=is_empty, + read_only=read_only, + item_rows=item_rows, + item_update_open=item_update_open, + delete_control=_delete_control(config_name, items_map, key) + if read_only == "rw" + else None, + ) + ) + + return _outer_card( + config_name=config_name, + config_type=config_type, + read_only=read_only, + value=value, + default=default, + description=description, + scope=config.get("scope"), + num_entries=num_entries, + items_update_value=items_update_value, + items_update_error=items_update_error, + items_update_open=items_update_open, + rows=rows, + add_control=add_control, + ) diff --git a/src/akkudoktoreos/server/dash/plan.py b/src/akkudoktoreos/server/dash/plan.py index bd11b11b..16bef2c6 100644 --- a/src/akkudoktoreos/server/dash/plan.py +++ b/src/akkudoktoreos/server/dash/plan.py @@ -25,6 +25,7 @@ from akkudoktoreos.core.emplan import ( EnergyManagementInstruction, EnergyManagementPlan, FRBCInstruction, + OMBCInstruction, ) from akkudoktoreos.optimization.optimization import OptimizationSolution from akkudoktoreos.server.dash.bokeh import Bokeh, bokey_apply_theme_to_plot @@ -72,7 +73,7 @@ solution_excludes = [ # Current state of solution displayed solution_visible: dict[str, bool] = { - "pv_energy_wh": True, + "pvforecast_power_w": True, "elec_price_amt_kwh": True, "feed_in_tariff_amt_kwh": True, } @@ -143,7 +144,7 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti solution_columns = [x for x in solution_columns if x not in instruction_columns] prediction_df = solution.prediction.to_dataframe() - if prediction_df.empty or len(prediction_df.columns) <= 1: + if prediction_df.empty: raise ValueError( f"Prediction DataFrame is empty or missing plottable columns: {list(prediction_df.columns)}" ) @@ -151,10 +152,12 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti raise ValueError( f"Prediction DataFrame is missing column 'date_time': {list(prediction_df.columns)}" ) - prediction_columns = list(prediction_df.columns) - - prediction_columns_to_join = prediction_df.columns.difference(df.columns) - df = df.join(prediction_df[prediction_columns_to_join], how="inner") + # Only plot if there are actual data columns beyond date_time + prediction_columns = [c for c in prediction_df.columns if c != "date_time"] + # No prediction data to plot — skip prediction section silently + if prediction_columns: + prediction_columns_to_join = prediction_df.columns.difference(df.columns) + df = df.join(prediction_df[prediction_columns_to_join], how="inner") # Exclude columns that currently do not have a value excludes = solution_excludes @@ -185,15 +188,20 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti validate_source(source) # Calculate minimum and maximum Range + power_w_min = 0.0 + power_w_max = 0.0 energy_wh_min = 0.0 energy_wh_max = 0.0 amt_kwh_min = 0.0 amt_kwh_max = 0.0 amt_min = 0.0 amt_max = 0.0 - soc_factor_min = 0.0 - soc_factor_max = 1.0 + factor_min = 0.0 + factor_max = 1.0 for col in df.columns: + if col.endswith("power_w"): + power_w_min = min(power_w_min, float(df[col].min())) + power_w_max = max(power_w_max, float(df[col].max())) if col.endswith("energy_wh"): energy_wh_min = min(energy_wh_min, float(df[col].min())) energy_wh_max = max(energy_wh_max, float(df[col].max())) @@ -207,10 +215,11 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti continue # Adjust to similar y-axis 0-point values_min_max = [ + (power_w_min, power_w_max), (energy_wh_min, energy_wh_max), (amt_kwh_min, amt_kwh_max), (amt_min, amt_max), - (soc_factor_min, soc_factor_max), + (factor_min, factor_max), ] # First get the maximum factor for the min value related the maximum value min_max_factor = 0.0 @@ -221,11 +230,15 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti min_max_factor = value_factor # Adapt the min values to have the same relative min/max factor on all y-axis + power_w_min = min_max_factor * power_w_max * -1.0 energy_wh_min = min_max_factor * energy_wh_max * -1.0 amt_kwh_min = min_max_factor * amt_kwh_max * -1.0 amt_min = min_max_factor * amt_max * -1.0 - soc_factor_min = min_max_factor * soc_factor_max * -1.0 + factor_min = min_max_factor * factor_max * -1.0 # add 5% to min and max values for better display + power_w_range_orig = power_w_max - power_w_min + power_w_max += 0.05 * power_w_range_orig + power_w_min -= 0.05 * power_w_range_orig energy_wh_range_orig = energy_wh_max - energy_wh_min energy_wh_max += 0.05 * energy_wh_range_orig energy_wh_min -= 0.05 * energy_wh_range_orig @@ -235,9 +248,9 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti amt_range_orig = amt_max - amt_min amt_max += 0.05 * amt_range_orig amt_min -= 0.05 * amt_range_orig - soc_factor_range_orig = soc_factor_max - soc_factor_min - soc_factor_max += 0.05 * soc_factor_range_orig - soc_factor_min -= 0.05 * soc_factor_range_orig + factor_range_orig = factor_max - factor_min + factor_max += 0.05 * factor_range_orig + factor_min -= 0.05 * factor_range_orig if eosstatus.eos_health is not None: last_run_datetime = eosstatus.eos_health["energy-management"]["last_run_datetime"] @@ -250,27 +263,31 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti title=f"Optimization Solution - last run: {last_run_datetime}", x_axis_type="datetime", x_axis_label=f"Datetime [localtime {date_time_tz}] - start: {start_datetime}", - y_axis_label="Energy [Wh]", + y_axis_label="Power [W]", sizing_mode="stretch_width", - y_range=Range1d(energy_wh_min, energy_wh_max), + y_range=Range1d(power_w_min, power_w_max), height=400, ) plot.extra_y_ranges = { - "factor": Range1d(soc_factor_min, soc_factor_max), # y2 - "amt_kwh": Range1d(amt_kwh_min, amt_kwh_max), # y3 - "amt": Range1d(amt_min, amt_max), # y4 + "energy": Range1d(energy_wh_min, energy_wh_max), # y2 + "factor": Range1d(factor_min, factor_max), # y3 + "amt_kwh": Range1d(amt_kwh_min, amt_kwh_max), # y4 + "amt": Range1d(amt_min, amt_max), # y5 } # y2 axis - y2_axis = LinearAxis(y_range_name="factor", axis_label="Factor [0.0..1.0]") + y2_axis = LinearAxis(y_range_name="energy", axis_label="Energy [Wh]") plot.add_layout(y2_axis, "left") # y3 axis - y3_axis = LinearAxis(y_range_name="amt_kwh", axis_label="Electricity Price [amount/kWh]") - y3_axis.axis_label_text_color = "red" - plot.add_layout(y3_axis, "right") + y3_axis = LinearAxis(y_range_name="factor", axis_label="Factor [0.0..1.0]") + plot.add_layout(y3_axis, "left") # y4 axis - y4_axis = LinearAxis(y_range_name="amt", axis_label="Amount") + y4_axis = LinearAxis(y_range_name="amt_kwh", axis_label="Electricty Price [Amount/kWh]") + y4_axis.axis_label_text_color = "red" plot.add_layout(y4_axis, "right") + # y5 axis + y5_axis = LinearAxis(y_range_name="amt", axis_label="Amount [Amount]") + plot.add_layout(y5_axis, "right") plot.toolbar.autohide = True @@ -309,7 +326,7 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti else: line_dash = "solid" if visible: - if col.endswith("energy_wh"): + if col.endswith("power_w"): r = plot.step( x="date_time_local", y=col, @@ -319,15 +336,16 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti color=color_palette[color], line_dash=line_dash, ) - elif col.endswith("soc_factor"): - r = plot.line( + elif col.endswith("energy_wh"): + r = plot.step( x="date_time_local", y=col, + mode="after", source=source, legend_label=col, color=color_palette[color], line_dash=line_dash, - y_range_name="factor", + y_range_name="energy", ) elif col.endswith("factor"): r = plot.step( @@ -374,7 +392,9 @@ def SolutionCard(solution: OptimizationSolution, config: SettingsEOS, data: Opti y_range_name="amt", ) else: - raise ValueError(f"Unexpected column name: {col}") + # Skip columns with unrecognized suffix rather than raising + logger.warning(f"Skipping column with unrecognized suffix: {col}") + r = None else: r = None @@ -542,9 +562,18 @@ def InstructionCard( icon = "washing-machine" else: icon = "play" - if isinstance(instruction, (DDBCInstruction, FRBCInstruction)): + + # Initialize defaults so all code paths are covered + summary = summary or "" + summary_detail = "" + + if isinstance(instruction, OMBCInstruction): + summary = f"{instruction.operation_mode_id}" + summary_detail = f"{instruction.operation_mode_factor:.2f}" + elif isinstance(instruction, (DDBCInstruction, FRBCInstruction)): summary = f"{instruction.operation_mode_id}" summary_detail = f"{instruction.operation_mode_factor}" + return Card( Details( Summary( diff --git a/src/akkudoktoreos/server/dash/prediction.py b/src/akkudoktoreos/server/dash/prediction.py index 15e208ff..78200880 100644 --- a/src/akkudoktoreos/server/dash/prediction.py +++ b/src/akkudoktoreos/server/dash/prediction.py @@ -6,12 +6,12 @@ from bokeh.models import ColumnDataSource, LinearAxis, Range1d from bokeh.plotting import figure from monsterui.franken import FT, Grid, P -from akkudoktoreos.core.pydantic import PydanticDateTimeDataFrame +from akkudoktoreos.core.pydantic import PydanticDateTimeSeries from akkudoktoreos.server.dash.bokeh import Bokeh, bokey_apply_theme_to_plot from akkudoktoreos.server.dash.components import Error -# bar width for 1 hour bars (time given in millseconds) -BAR_WIDTH_1HOUR = 1000 * 60 * 60 +# bar width for 15 minutes bars (time given in millseconds) +BAR_WIDTH_15MIN = 1000 * 60 * 15 def PVForecast(predictions: pd.DataFrame, config: dict, date_time_tz: str, dark: bool) -> FT: @@ -30,7 +30,7 @@ def PVForecast(predictions: pd.DataFrame, config: dict, date_time_tz: str, dark: x="date_time", top="pvforecast_ac_power", source=source, - width=BAR_WIDTH_1HOUR * 0.8, + width=BAR_WIDTH_15MIN * 0.8, legend_label="AC Power", color="lightblue", ) @@ -54,7 +54,7 @@ def ElectricityPriceForecast( ), title=f"Electricity Price Prediction ({provider})", x_axis_label=f"Datetime [localtime {date_time_tz}]", - y_axis_label="Price [amount/kWh]", + y_axis_label="Price [Amt./kWh]", sizing_mode="stretch_width", height=400, ) @@ -62,7 +62,7 @@ def ElectricityPriceForecast( x="date_time", top="elecprice_marketprice_kwh", source=source, - width=BAR_WIDTH_1HOUR * 0.8, + width=BAR_WIDTH_15MIN * 0.8, legend_label="Market Price", color="lightblue", ) @@ -208,7 +208,9 @@ def Prediction(eos_host: str, eos_port: Union[str, int], data: Optional[dict] = if data and data.get("dark", None) == "true": dark = True - # Get current configuration from server + # --------------------------------------------------------------------- + # Get configuration + # --------------------------------------------------------------------- try: result = requests.get(f"{server}/v1/config", timeout=10) result.raise_for_status() @@ -220,31 +222,63 @@ def Prediction(eos_host: str, eos_port: Union[str, int], data: Optional[dict] = ) config = result.json() - # Get Forecasts + # --------------------------------------------------------------------- + # Describe how every prediction should be retrieved. + # --------------------------------------------------------------------- + prediction_requests = [ + ("pvforecast_ac_power", "first", "ffill"), + ("elecprice_marketprice_kwh", "first", "ffill"), + ("weather_relative_humidity", "mean", "linear"), + ("weather_temp_air", "mean", "linear"), + ("weather_ghi", "mean", "linear"), + ("weather_dni", "mean", "linear"), + ("weather_dhi", "mean", "linear"), + ("loadforecast_power_w", "first", "ffill"), + ("loadakkudoktor_std_power_w", "first", "ffill"), + ("loadakkudoktor_mean_power_w", "first", "ffill"), + ] + + # --------------------------------------------------------------------- + # Fetch all series + # --------------------------------------------------------------------- + series_list = [] + try: - params = { - "keys": [ - "pvforecast_ac_power", - "elecprice_marketprice_kwh", - "weather_relative_humidity", - "weather_temp_air", - "weather_ghi", - "weather_dni", - "weather_dhi", - "loadforecast_power_w", - "loadakkudoktor_std_power_w", - "loadakkudoktor_mean_power_w", - ], - } - result = requests.get(f"{server}/v1/prediction/dataframe", params=params, timeout=10) - result.raise_for_status() - predictions = PydanticDateTimeDataFrame(**result.json()).to_dataframe() + for options in prediction_requests: + key = options[0] + resample_method = options[1] + fill_method = options[2] + + params = { + "key": key, + "interval": "15 minutes", + "processing": "resampled", + "resample_method": resample_method, + "fill_method": fill_method, + } + + result = requests.get( + f"{server}/v1/prediction/series", + params=params, + timeout=10, + ) + result.raise_for_status() + + series = PydanticDateTimeSeries(**result.json()).to_series().rename(key) + series_list.append(series) + except requests.exceptions.HTTPError as err: detail = result.json()["detail"] return Error(f"Can not retrieve predictions from {server}: {err}, {detail}") except Exception as err: return Error(f"Can not retrieve predictions from {server}: {err}") + # --------------------------------------------------------------------- + # Merge into dataframe + # --------------------------------------------------------------------- + predictions = pd.concat(series_list, axis=1).reset_index() + predictions.rename(columns={"index": "date_time"}, inplace=True) + # Remove time offset from UTC to get naive local time and make bokeh plot in local time date_time_tz = predictions["date_time"].dt.tz predictions["date_time"] = pd.to_datetime(predictions["date_time"]).dt.tz_localize(None) diff --git a/src/akkudoktoreos/server/dash/uihints.py b/src/akkudoktoreos/server/dash/uihints.py new file mode 100644 index 00000000..366d8c59 --- /dev/null +++ b/src/akkudoktoreos/server/dash/uihints.py @@ -0,0 +1,419 @@ +"""UI hint registry for EOSdash configuration forms. + +This module decouples UI rendering decisions from both the domain models and the +main ``Configuration()`` render function. Instead of a long if/elif chain that +maps config field paths to form factories, all those decisions live here as +structured ``UiHint`` entries in ``UI_HINTS``. + +Typical usage in ``configuration.py``:: + + from akkudoktoreos.server.dash.uihints import UI_HINTS, resolve_form_factory + + hint = UI_HINTS.get(config["name"]) + if hint and hint.form == "items": + rows.append(ConfigItemsCard(config, hint, config_details, config_update_latest)) + elif not config["deprecated"]: + update_form_factory = resolve_form_factory(hint, config_details) if hint else None + rows.append(ConfigCard(..., update_form_factory)) + +``ConfigItemsCard`` must live in ``configuration.py`` because it depends on +``create_config_details`` and ``config_update_latest``. This module only +carries the *data* that drives it. +""" + +import json +from dataclasses import dataclass, field +from typing import Any, Callable, Literal, Optional + +from akkudoktoreos.server.dash.components import ( + make_config_update_list_form, + make_config_update_map_form, + make_config_update_time_windows_windows_form, + make_config_update_value_form, +) + +# --------------------------------------------------------------------------- +# Form type literals +# --------------------------------------------------------------------------- + +UiFormType = Literal[ + "text", # plain text input (default) + "select", # single-value dropdown + "select_list", # add/delete multi-value list + "map", # key/value pair editor + "time_windows", # time-window sequence editor + "items", # expandable list of sub-model cards + "map_items", # expandable map of sub-model cards +] + + +# --------------------------------------------------------------------------- +# UiHint dataclass +# --------------------------------------------------------------------------- + + +@dataclass +class UiHint: + """Rendering hints for a single configuration field. + + Attributes: + form: + Which form widget to use. Defaults to ``"text"``. + + options: + Static allowed values for ``"select"`` / ``"select_list"``. + + options_from: + Dotted config-field path whose runtime value provides the + option list (JSON-encoded ``list[str]``). Takes precedence + over ``options`` when both are set. + + param_from: + Dotted config-field path for a secondary runtime parameter. + Used by ``"map"`` for the *keys* dropdown. + + append_none: + Append ``"None"`` to the resolved option list. Useful for + nullable single-value selects such as ``*.provider`` fields. + + value_description: + Label for the extra numeric column in the ``"time_windows"`` + form (e.g. ``"electricity_price_kwh [Amt/kWh]"``). When + ``None`` no value column is rendered. + + item_model: + *``"items"`` only.* The Pydantic model class (or instance) + whose fields define the per-item sub-cards, e.g. + ``PVForecastPlaneSetting``. Set via ``_ensure_item_models()`` + at first use to avoid circular imports. + + item_path: + *``"items"`` only.* Dotted path that locates the list inside + the synthetic config dict built from the field value. Used to + construct the ``values_prefix`` for ``create_config_details``. + + Example: planes are wrapped as + ``{"pvforecast": {"planes": }}`` so ``item_path`` is + ``"pvforecast.planes"``. + + max_items_from: + *``"items"`` only.* Dotted config-field path whose integer + value caps the number of rendered sub-cards (e.g. + ``"pvforecast.max_planes"``). When ``None`` the length of + the actual list is used instead. + """ + + form: UiFormType = "text" + + # select / select_list / map + options: list[str] = field(default_factory=list) + options_from: Optional[str] = None + param_from: Optional[str] = None + append_none: bool = False + + # time_windows + value_description: Optional[str] = None + + # items + item_model: Optional[Any] = None + item_path: Optional[str] = None + max_items_from: Optional[str] = None + + +# --------------------------------------------------------------------------- +# Registry +# --------------------------------------------------------------------------- + +UI_HINTS: dict[str, UiHint] = { + # ------------------------------------------------------------------ + # Adapter - Home Assistant adapter + # ------------------------------------------------------------------ + "adapter.homeassistant.config_entity_ids": UiHint( + form="map", + options_from="adapter.homeassistant.homeassistant_entity_ids", + ), + "adapter.homeassistant.load_emr_entity_ids": UiHint( + form="select_list", + options_from="adapter.homeassistant.homeassistant_entity_ids", + ), + "adapter.homeassistant.grid_export_emr_entity_ids": UiHint( + form="select_list", + options_from="adapter.homeassistant.homeassistant_entity_ids", + ), + "adapter.homeassistant.grid_import_emr_entity_ids": UiHint( + form="select_list", + options_from="adapter.homeassistant.homeassistant_entity_ids", + ), + "adapter.homeassistant.pv_production_emr_entity_ids": UiHint( + form="select_list", + options_from="adapter.homeassistant.homeassistant_entity_ids", + ), + "adapter.homeassistant.device_measurement_entity_ids": UiHint( + form="map", + param_from="devices.measurement_keys", + options_from="adapter.homeassistant.homeassistant_entity_ids", + ), + "adapter.homeassistant.device_instruction_entity_ids": UiHint( + form="select_list", + options_from="adapter.homeassistant.eos_device_instruction_entity_ids", + ), + "adapter.homeassistant.solution_entity_ids": UiHint( + form="select_list", + options_from="adapter.homeassistant.eos_solution_entity_ids", + ), + # ------------------------------------------------------------------ + # Devices + # ------------------------------------------------------------------ + "devices.batteries": UiHint( + form="items", + item_path="devices.batteries", + ), + "devices.electric_vehicles": UiHint( + form="items", + item_path="devices.electric_vehicles", + ), + "devices.home_appliances": UiHint( + form="items", + item_path="devices.home_appliances", + ), + # Sub-field hint for the time_windows field inside each appliance entry + "devices.home_appliances.cycle_time_windows.windows": UiHint( + form="time_windows", + value_description="cycle index (0-based)", + ), + # ------------------------------------------------------------------ + # Electricity price — fixed time windows + # ------------------------------------------------------------------ + "elecprice.provider": UiHint( + form="select", + options_from="elecprice.providers", + append_none=True, + ), + "elecprice.elecpricefixed.time_windows.windows": UiHint( + form="time_windows", + value_description="electricity_price_kwh [Amt/kWh]", + ), + # ------------------------------------------------------------------ + # EMS + # ------------------------------------------------------------------ + "ems.mode": UiHint( + form="select", + options_from="ems.modes", + ), + # ------------------------------------------------------------------ + # Load + # ------------------------------------------------------------------ + "load.provider": UiHint( + form="select", + options_from="load.providers", + append_none=True, + ), + # ------------------------------------------------------------------ + # Optimization + # ------------------------------------------------------------------ + "optimization.algorithm": UiHint( + form="select", + options_from="optimization.algorithms", + ), + # ------------------------------------------------------------------ + # PV forecast — planes + # item_model is populated lazily by _ensure_item_models() below. + # ------------------------------------------------------------------ + "pvforecast.provider": UiHint( + form="select", + options_from="pvforecast.providers", + append_none=True, + ), + "pvforecast.planes": UiHint( + form="items", + item_path="pvforecast.planes", + max_items_from="pvforecast.max_planes", + ), + # Per-plane sub-fields; resolved by hint_for_indexed_field() + "pvforecast.planes.pvtechchoice": UiHint( + form="select", + options=["crystSi", "CIS", "CdTe", "Unknown"], + ), + "pvforecast.planes.mountingplace": UiHint( + form="select", + options=["free", "building"], + ), + # ------------------------------------------------------------------ + # Weather + # ------------------------------------------------------------------ + "weather.providers": UiHint( + form="select_list", + options_from="weather.providers", + ), +} + + +# --------------------------------------------------------------------------- +# Lazy item_model resolution (avoids circular imports at module load time) +# --------------------------------------------------------------------------- + +_item_models_resolved = False + + +def _ensure_item_models() -> None: + """Populate ``item_model`` on any ``"items"`` hints that need it. + + Domain model imports are deferred to this function so that importing + ``uihints`` early in the boot sequence does not trigger circular imports. + """ + if UI_HINTS["pvforecast.planes"].item_model is None: + from akkudoktoreos.prediction.pvforecast import ( # noqa: PLC0415 + PVForecastPlaneSetting, + ) + + UI_HINTS["pvforecast.planes"].item_model = PVForecastPlaneSetting + + if UI_HINTS["devices.batteries"].item_model is None: + from akkudoktoreos.devices.devices import ( + BatteriesCommonSettings, + ) + + UI_HINTS["devices.batteries"].item_model = BatteriesCommonSettings + + if UI_HINTS["devices.electric_vehicles"].item_model is None: + from akkudoktoreos.devices.devices import ( + BatteriesCommonSettings, + ) + + UI_HINTS["devices.electric_vehicles"].item_model = BatteriesCommonSettings + + if UI_HINTS["devices.home_appliances"].item_model is None: + from akkudoktoreos.devices.devices import ( + HomeApplianceCommonSettings, + ) + + UI_HINTS["devices.home_appliances"].item_model = HomeApplianceCommonSettings + + +def resolve_item_model(hint: UiHint) -> Optional[Any]: + """Return the ``item_model`` for an ``"items"`` hint, resolving lazily. + + Args: + hint: A ``UiHint`` with ``form == "items"``. + + Returns: + The model class or instance, or ``None`` if unset. + """ + global _item_models_resolved + if not _item_models_resolved: + _ensure_item_models() + _item_models_resolved = True + return hint.item_model + + +# --------------------------------------------------------------------------- +# Resolver +# --------------------------------------------------------------------------- + + +def resolve_form_factory( + hint: UiHint, + config_details: dict[str, dict], +) -> Optional[Callable]: + """Materialise a ``UiHint`` into a concrete ``update_form_factory`` callable. + + For ``"items"`` hints this returns ``None`` — the caller must dispatch + to ``ConfigItemsCard`` separately after checking ``hint.form == "items"``. + For ``"text"`` this returns ``None`` — the caller uses the default + plain-text input. All other form types return a callable. + + Args: + hint: + The ``UiHint`` to materialise. + config_details: + The fully-resolved config detail dict from + ``create_config_details()``. Used to look up runtime option + lists via ``options_from`` / ``param_from``. + + Returns: + A ``(config_name: str, value: str) -> Grid`` factory, or ``None``. + """ + + def _load_list(key: str) -> list[str]: + try: + result = json.loads(config_details[key]["value"]) + return result if isinstance(result, list) else [] + except Exception: + return [] + + if hint.form in ("text", "items", "map_items"): + return None + + if hint.form == "select": + options: list[str] = [] + if hint.options_from: + options = _load_list(hint.options_from) + if not options: + options = list(hint.options) + if hint.append_none and "None" not in options: + options.append("None") + return make_config_update_value_form(options) + + if hint.form == "select_list": + options = [] + if hint.options_from: + options = _load_list(hint.options_from) + if not options: + options = list(hint.options) + return make_config_update_list_form(options) + + if hint.form == "map": + available_values: Optional[list[str]] = None + available_keys: Optional[list[str]] = None + if hint.options_from: + available_values = _load_list(hint.options_from) or None + if hint.param_from: + available_keys = _load_list(hint.param_from) or None + return make_config_update_map_form(available_keys, available_values) + + if hint.form == "time_windows": + return make_config_update_time_windows_windows_form( + value_description=hint.value_description, + ) + + return None # unreachable for valid UiFormType values + + +# --------------------------------------------------------------------------- +# Suffix-based lookup for indexed sub-model fields +# --------------------------------------------------------------------------- + + +def hint_for_indexed_field(field_name: str, list_path: str) -> Optional[UiHint]: + """Return the UiHint for a sub-field inside an 'items' or 'map_items' list. + + Strips the index segment (numeric for lists, any string for maps) from a + dotted field name and looks up the canonical hint key. + + Args: + field_name: + Full dotted config name including the index, e.g. + ``"pvforecast.planes.2.mountingplace"`` or + ``"devices.home_appliances.dishwasher1.time_windows"``. + list_path: + The ``item_path`` from the parent ``UiHint``, e.g. + ``"pvforecast.planes"`` or ``"devices.home_appliances"``. + + Returns: + The matching ``UiHint``, or ``None`` if none is registered. + """ + prefix = list_path + "." + if not field_name.startswith(prefix): + return None + remainder = field_name[len(prefix) :] # e.g. "2.mountingplace" or "dishwasher1.time_windows" + parts = remainder.split(".", 1) + if len(parts) < 2: + return None + # Accept both numeric (list) and string (map) index segments + canonical = list_path + "." + parts[1] + return UI_HINTS.get(canonical) + + +def hint_for_plane_field(field_name: str) -> Optional[UiHint]: + """Back-compat wrapper — prefer ``hint_for_indexed_field`` directly.""" + return hint_for_indexed_field(field_name, "pvforecast.planes") diff --git a/src/akkudoktoreos/server/eos.py b/src/akkudoktoreos/server/eos.py index 8faee8c2..e1d1b67f 100755 --- a/src/akkudoktoreos/server/eos.py +++ b/src/akkudoktoreos/server/eos.py @@ -64,11 +64,15 @@ from akkudoktoreos.optimization.genetic0.genetic0visualize import ( genetic0_prepare_visualize, ) from akkudoktoreos.optimization.genetic.geneticsolution import GeneticSolution -from akkudoktoreos.optimization.optimization import OptimizationSolution +from akkudoktoreos.optimization.optimization import ( + OptimizationAlgorithm, + OptimizationSolution, +) from akkudoktoreos.prediction.elecprice import ElecPriceCommonSettings from akkudoktoreos.prediction.load import LoadCommonSettings from akkudoktoreos.prediction.loadakkudoktor import LoadAkkudoktorCommonSettings from akkudoktoreos.prediction.pvforecast import PVForecastCommonSettings +from akkudoktoreos.prediction.pvforecastpvlib import _cec_inverters, _cec_modules from akkudoktoreos.server.rest.error import ( EOSProblem, create_error_page, @@ -1770,6 +1774,18 @@ async def fastapi_prediction_range_delete( ) from e +@app.get("/v1/prediction/pvforecast/pvlib/modules", tags=["prediction"]) +def fastapi_prediction_pvforecast_modules_get() -> list[str]: + """Get module names supported by PVForecast PVLib provider.""" + return _cec_modules().columns.tolist() + + +@app.get("/v1/prediction/pvforecast/pvlib/inverters", tags=["prediction"]) +def fastapi_prediction_pvforecast_inverters_get() -> list[str]: + """Get inverter names supported by PVForecast PVLib provider.""" + return _cec_inverters().columns.tolist() + + @app.get("/v1/energy-management/optimization/solution", tags=["energy-management"]) def fastapi_energy_management_optimization_solution_get() -> OptimizationSolution: """Get the latest solution of the optimization.""" @@ -1790,7 +1806,7 @@ def fastapi_energy_management_optimization_solution_get() -> OptimizationSolutio @app.get("/v1/energy-management/optimization/solution/{algorithm}", tags=["energy-management"]) async def fastapi_energy_management_optimization_solution_algorithm_get( - algorithm: str, + algorithm: OptimizationAlgorithm, ) -> Union[GeneticSolution, Genetic0Solution]: """Get the latest algorithm specific solution of the optimization. @@ -1799,7 +1815,6 @@ async def fastapi_energy_management_optimization_solution_algorithm_get( """ solution: Optional[Union[GeneticSolution, Genetic0Solution]] = None - algorithm = algorithm.upper() if algorithm not in get_config().optimization.algorithms: raise EOSProblem( status=404, @@ -1807,9 +1822,9 @@ async def fastapi_energy_management_optimization_solution_algorithm_get( detail=f"Optimization algorithm '{algorithm}' unknown.", ) - if algorithm == "GENETIC": + if algorithm == OptimizationAlgorithm.GENETIC: solution = get_ems().genetic_solution() - elif algorithm == "GENETIC0": + elif algorithm == OptimizationAlgorithm.GENETIC0: solution = get_ems().genetic0_solution() if solution is None: @@ -2162,7 +2177,7 @@ async def fastapi_optimize( await get_ems().run( start_datetime=start_datetime, mode=EnergyManagementMode.OPTIMIZATION, - algorithm="GENETIC0", + algorithm=OptimizationAlgorithm.GENETIC0, genetic0_parameters=parameters, genetic0_generations=ngen, ) diff --git a/tests/conftest.py b/tests/conftest.py index 2eff0cee..a4fc6392 100644 --- a/tests/conftest.py +++ b/tests/conftest.py @@ -1,7 +1,10 @@ + +import bz2 import hashlib import json import logging import os +import pickle import signal import subprocess import sys @@ -14,6 +17,7 @@ from pathlib import Path from typing import Generator, Optional, Union from unittest.mock import PropertyMock, patch +import pandas as pd import pendulum import psutil import pytest @@ -176,6 +180,74 @@ def cfg_non_existent(request): # ------------------------------------ +@pytest.fixture(scope="session") +def cec_databases_data() -> tuple[pd.DataFrame, pd.DataFrame]: + """Load CEC test databases once per test session.""" + DIR_TESTDATA = Path(__file__).parent / "testdata" / "pvforecastpvlib" + FILE_TESTDATA_CEC_INVERTERS_PBZ2 = DIR_TESTDATA / "cec_inverters.pbz2" + FILE_TESTDATA_CEC_MODULES_PBZ2 = DIR_TESTDATA / "cec_modules.pbz2" + + with bz2.BZ2File(FILE_TESTDATA_CEC_MODULES_PBZ2, "rb") as f: + modules: pd.DataFrame = pickle.load(f) + with bz2.BZ2File(FILE_TESTDATA_CEC_INVERTERS_PBZ2, "rb") as f: + inverters: pd.DataFrame = pickle.load(f) + + return modules, inverters + + +@pytest.fixture(autouse=True) +def cec_databases(monkeypatch, cec_databases_data) -> tuple[pd.DataFrame, pd.DataFrame]: + """Short-circuit CEC database access for every test (per-test patch, session-cached data). + + Config requests the database in PVForecastPVLibCommonSettings by a computed_field. + + To undo this fixture in a specific class do: + @pytest.fixture(autouse=True) + def cec_databases(self): + yield None + """ + modules, inverters = cec_databases_data + + def fake_update_cec_database() -> None: + #print(f"_update_cec_database faked") + pass + + def fake_load_cec_database(path: Path) -> pd.DataFrame: + #print(f"_loadcec_database faked") + if "inverter" in path.name: + return inverters + if "module" in path.name: + return modules + raise ValueError(f"Unexpected CEC database path in test: {path}") + + def fake_cec_inverters() -> pd.DataFrame: + #print(f"_cec_inverters faked") + return inverters + + def fake_cec_modules() -> pd.DataFrame: + #print(f"_cec_modules faked") + return modules + + monkeypatch.setattr( + "akkudoktoreos.prediction.pvforecastpvlib._update_cec_database", + fake_update_cec_database, + ) + monkeypatch.setattr( + "akkudoktoreos.prediction.pvforecastpvlib._load_cec_database", + fake_load_cec_database, + ) + monkeypatch.setattr( + "akkudoktoreos.prediction.pvforecastpvlib._cec_inverters", + fake_cec_inverters, + ) + monkeypatch.setattr( + "akkudoktoreos.prediction.pvforecastpvlib._cec_modules", + fake_cec_modules, + ) + + return modules, inverters + + @pytest.fixture def config_default_dirs(tmpdir): """Fixture that provides a list of directories to be used as config dir.""" @@ -234,6 +306,7 @@ def user_data_dir(config_default_dirs): @pytest.fixture def config_eos_factory( + cec_databases, disable_debug_logging, user_config_dir, user_data_dir, diff --git a/tests/single_test_genetic0optimization.py b/tests/single_test_genetic0optimization.py index 24a093df..36979f54 100755 --- a/tests/single_test_genetic0optimization.py +++ b/tests/single_test_genetic0optimization.py @@ -17,6 +17,7 @@ from akkudoktoreos.core.emsettings import EnergyManagementMode from akkudoktoreos.optimization.genetic0.genetic0params import ( Genetic0OptimizationParameters, ) +from akkudoktoreos.optimization.optimization import OptimizationAlgorithm from akkudoktoreos.utils.datetimeutil import to_datetime config_eos = get_config() @@ -431,7 +432,7 @@ def run_optimization( ems_eos.run( start_datetime=start_datetime, mode=EnergyManagementMode.OPTIMIZATION, - algorithm="GENETIC0", + algorithm=OptimizationAlgorithm.GENETIC0, genetic0_parameters=parameters, genetic0_generations=ngen, genetic0_seed=seed, diff --git a/tests/single_test_optimization.py b/tests/single_test_optimization.py index a8c0a3fe..1e93275e 100755 --- a/tests/single_test_optimization.py +++ b/tests/single_test_optimization.py @@ -17,6 +17,7 @@ from akkudoktoreos.core.emsettings import EnergyManagementMode from akkudoktoreos.optimization.genetic.geneticparams import ( GeneticOptimizationParameters, ) +from akkudoktoreos.optimization.optimization import OptimizationAlgorithm from akkudoktoreos.utils.datetimeutil import to_datetime config_eos = get_config() @@ -432,6 +433,7 @@ def run_optimization( ems_eos.run( start_datetime=start_datetime, mode=EnergyManagementMode.OPTIMIZATION, + algorithm=OptimizationAlgorithm.GENETIC, genetic_parameters=parameters, genetic_generations=ngen, genetic_seed=seed, diff --git a/tests/test_docstringrst.py b/tests/test_docstringrst.py index 80107d93..1d096e0b 100644 --- a/tests/test_docstringrst.py +++ b/tests/test_docstringrst.py @@ -46,6 +46,16 @@ IGNORE_LOCATIONS = [ # pathlib r"\.Path.*", + # PVLib + r"\.pvlib.*", + r"\.PVSystem.*", + r"\.disc.*", + r"\.Location.*", + r"\.ModelChain.*", + r"\.retrieve_sam.*", + r"\.get_solarposition.*", + r"\.TEMPERATURE_MODEL_PARAMETERS.*", + # MarkdownIt r"\.MarkdownIt.*", diff --git a/tests/test_prediction.py b/tests/test_prediction.py index d88d447a..ee4e7fd9 100644 --- a/tests/test_prediction.py +++ b/tests/test_prediction.py @@ -26,6 +26,7 @@ from akkudoktoreos.prediction.prediction import ( from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor from akkudoktoreos.prediction.pvforecastforecastsolar import PVForecastForecastSolar from akkudoktoreos.prediction.pvforecastimport import PVForecastImport +from akkudoktoreos.prediction.pvforecastpvlib import PVForecastPVLib from akkudoktoreos.prediction.pvforecastpvnode import PVForecastPVNode from akkudoktoreos.prediction.pvforecastsolcast import PVForecastSolcast from akkudoktoreos.prediction.pvforecastvrm import PVForecastVrm @@ -45,6 +46,10 @@ def prediction(): def forecast_providers(): """Fixture for singleton forecast provider instances.""" return [ + WeatherBrightSky(), + WeatherClearOutside(), + WeatherImport(), + WeatherOpenMeteo(), ElecPriceAkkudoktor(), ElecPriceEnergyCharts(), ElecPriceFixed(), @@ -58,18 +63,15 @@ def forecast_providers(): FeedInTariffTibber(), LoadAkkudoktor(), LoadAkkudoktorAdjusted(), - LoadVrm(), LoadImport(), + LoadVrm(), PVForecastAkkudoktor(), - PVForecastVrm(), - PVForecastPVNode(), PVForecastForecastSolar(), - PVForecastSolcast(), PVForecastImport(), - WeatherBrightSky(), - WeatherClearOutside(), - WeatherOpenMeteo(), - WeatherImport(), + PVForecastPVLib(), + PVForecastPVNode(), + PVForecastSolcast(), + PVForecastVrm(), ] @@ -102,31 +104,32 @@ def test_initialization(prediction, forecast_providers): def test_provider_sequence(prediction): """Test the provider sequence is maintained in the Prediction instance.""" - assert isinstance(prediction.providers[0], ElecPriceAkkudoktor) - assert isinstance(prediction.providers[1], ElecPriceEnergyCharts) - assert isinstance(prediction.providers[2], ElecPriceFixed) - assert isinstance(prediction.providers[3], ElecPriceImport) - assert isinstance(prediction.providers[4], ElecPriceTibber) - assert isinstance(prediction.providers[5], FeedInTariffAkkudoktor) - assert isinstance(prediction.providers[6], FeedInTariffDvhubOnline) - assert isinstance(prediction.providers[7], FeedInTariffEnergyCharts) - assert isinstance(prediction.providers[8], FeedInTariffFixed) - assert isinstance(prediction.providers[9], FeedInTariffImport) - assert isinstance(prediction.providers[10], FeedInTariffTibber) - assert isinstance(prediction.providers[11], LoadAkkudoktor) - assert isinstance(prediction.providers[12], LoadAkkudoktorAdjusted) - assert isinstance(prediction.providers[13], LoadVrm) - assert isinstance(prediction.providers[14], LoadImport) - assert isinstance(prediction.providers[15], PVForecastAkkudoktor) - assert isinstance(prediction.providers[16], PVForecastVrm) - assert isinstance(prediction.providers[17], PVForecastPVNode) - assert isinstance(prediction.providers[18], PVForecastForecastSolar) - assert isinstance(prediction.providers[19], PVForecastSolcast) - assert isinstance(prediction.providers[20], PVForecastImport) - assert isinstance(prediction.providers[21], WeatherBrightSky) - assert isinstance(prediction.providers[22], WeatherClearOutside) - assert isinstance(prediction.providers[23], WeatherOpenMeteo) - assert isinstance(prediction.providers[24], WeatherImport) + assert isinstance(prediction.providers[0], WeatherBrightSky) + assert isinstance(prediction.providers[1], WeatherClearOutside) + assert isinstance(prediction.providers[2], WeatherImport) + assert isinstance(prediction.providers[3], WeatherOpenMeteo) + assert isinstance(prediction.providers[4], ElecPriceAkkudoktor) + assert isinstance(prediction.providers[5], ElecPriceEnergyCharts) + assert isinstance(prediction.providers[6], ElecPriceFixed) + assert isinstance(prediction.providers[7], ElecPriceImport) + assert isinstance(prediction.providers[8], ElecPriceTibber) + assert isinstance(prediction.providers[9], FeedInTariffAkkudoktor) + assert isinstance(prediction.providers[10], FeedInTariffDvhubOnline) + assert isinstance(prediction.providers[11], FeedInTariffEnergyCharts) + assert isinstance(prediction.providers[12], FeedInTariffFixed) + assert isinstance(prediction.providers[13], FeedInTariffImport) + assert isinstance(prediction.providers[14], FeedInTariffTibber) + assert isinstance(prediction.providers[15], LoadAkkudoktor) + assert isinstance(prediction.providers[16], LoadAkkudoktorAdjusted) + assert isinstance(prediction.providers[17], LoadImport) + assert isinstance(prediction.providers[18], LoadVrm) + assert isinstance(prediction.providers[19], PVForecastAkkudoktor) + assert isinstance(prediction.providers[20], PVForecastForecastSolar) + assert isinstance(prediction.providers[21], PVForecastImport) + assert isinstance(prediction.providers[22], PVForecastPVLib) + assert isinstance(prediction.providers[23], PVForecastPVNode) + assert isinstance(prediction.providers[24], PVForecastSolcast) + assert isinstance(prediction.providers[25], PVForecastVrm) def test_provider_by_id(prediction, forecast_providers): @@ -145,20 +148,26 @@ def test_prediction_repr(prediction): assert "ElecPriceImport" in result assert "ElecPriceTibber" in result assert "FeedInTariffAkkudoktor" in result + assert "FeedInTariffDvhubOnline" in result assert "FeedInTariffEnergyCharts" in result assert "FeedInTariffFixed" in result assert "FeedInTariffImport" in result assert "FeedInTariffTibber" in result assert "LoadAkkudoktor" in result - assert "LoadVrm" in result + assert "LoadAkkudoktorAdjusted" in result assert "LoadImport" in result + assert "LoadVrm" in result assert "PVForecastAkkudoktor" in result - assert "PVForecastVrm" in result + assert "PVForecastForecastSolar" in result assert "PVForecastImport" in result + assert "PVForecastPVLib" in result + assert "PVForecastPVNode" in result + assert "PVForecastSolcast" in result + assert "PVForecastVrm" in result assert "WeatherBrightSky" in result assert "WeatherClearOutside" in result - assert "WeatherOpenMeteo" in result assert "WeatherImport" in result + assert "WeatherOpenMeteo" in result @pytest.mark.asyncio diff --git a/tests/test_pvforecastpvlib.py b/tests/test_pvforecastpvlib.py new file mode 100644 index 00000000..b680e4db --- /dev/null +++ b/tests/test_pvforecastpvlib.py @@ -0,0 +1,1715 @@ + +"""Tests for PVForecastPVLib prediction provider.""" + +import bz2 +import pickle +from pathlib import Path +from unittest.mock import MagicMock, Mock, patch + +import numpy as np +import pandas as pd +import pytest + +from akkudoktoreos.core.cache import CacheFileStore +from akkudoktoreos.prediction.prediction import Prediction +from akkudoktoreos.prediction.pvforecastpvlib import ( + PVForecastPVLib, + PVForecastPVLibCommonSettings, + _cec_cache, + _cec_inverters, + _cec_inverters_path, + _cec_modules, + _cec_modules_path, + _load_cec_database, +) +from akkudoktoreos.utils.datetimeutil import to_duration + +DIR_TESTDATA = Path(__file__).parent / "testdata" / "pvforecastpvlib" + +FILE_TESTDATA_CEC_INVERTERS_PBZ2 = DIR_TESTDATA / "cec_inverters.pbz2" +FILE_TESTDATA_CEC_MODULES_PBZ2 = DIR_TESTDATA / "cec_modules.pbz2" + +# --------------------------------------------------------------------------- +# Fixtures +# --------------------------------------------------------------------------- + +# conftest for cec_databases fixture + +@pytest.fixture +def provider(monkeypatch, config_eos): + """Create a fresh PVForecastPVLib provider.""" + + monkeypatch.setenv( + "EOS_PVFORECAST__PVFORECAST_PROVIDER", + "PVForecastPVLib", + ) + + PVForecastPVLib.reset_instance() + return PVForecastPVLib() + +@pytest.fixture +def cache_store(): + """Provide a fresh cache store.""" + return CacheFileStore() + + +@pytest.fixture(autouse=True) +def clear_database_cache(): + """Clear global CEC cache before every test.""" + _cec_cache.clear() + yield + _cec_cache.clear() + + +@pytest.fixture +def sample_settings_4planes(config_eos): + """Fixture that adds settings data to the global config.""" + settings = { + "general": { + "latitude": 52.52, + "longitude": 13.405, + }, + "prediction": { + "hours": 48, + "historic_hours": 24, + }, + "pvforecast": { + "provider": "PVForecastPVLib", + "max_planes": 4, + "planes": [ + { + "surface_tilt": 7, + "surface_azimuth": 170, + "userhorizon": [20, 27, 22, 20], + "peakpower": 5.0, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", + "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, + }, + { + "surface_tilt": 7, + "surface_azimuth": 90, + "userhorizon": [30, 30, 30, 50], + "peakpower": 4.8, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", + "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, + }, + { + "surface_tilt": 60, + "surface_azimuth": 140, + "userhorizon": [60, 30, 0, 30], + "peakpower": 1.4, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", + "inverter_paco": 2000, + "modules_per_string": 5, + "strings_per_inverter": 1, + }, + { + "surface_tilt": 45, + "surface_azimuth": 185, + "userhorizon": [45, 25, 30, 60], + "peakpower": 1.6, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", + "inverter_paco": 1400, + "modules_per_string": 4, + "strings_per_inverter": 1, + }, + ], + }, + } + + # Merge settings to config + config_eos.merge_settings_from_dict(settings) + assert config_eos.pvforecast.provider == "PVForecastPVLib" + return config_eos + + +@pytest.fixture +def sample_settings_1plane(config_eos): + """Fixture that adds settings data to the global config.""" + settings = { + "general": { + "latitude": 52.52, + "longitude": 13.405, + }, + "prediction": { + "hours": 48, + "historic_hours": 24, + }, + "pvforecast": { + "provider": "PVForecastPVLib", + "planes": [ + { + "surface_tilt": 7, + "surface_azimuth": 170, + "userhorizon": [20, 27, 22, 20], + "peakpower": 5.0, + "module_model": "AXITEC_AC_410MH_144S", + "inverter_model": "Sungrow__SH25T", + "inverter_paco": 10000, + "modules_per_string": 12, + "strings_per_inverter": 1, + }, + ], + }, + } + + # Merge settings to config + config_eos.merge_settings_from_dict(settings) + assert config_eos.pvforecast.provider == "PVForecastPVLib" + return config_eos + + +# --------------------------------------------------------------------------- +# Database +# --------------------------------------------------------------------------- + +class TestLoadUpdateCECDatabase: + """Test for CEC databases.""" + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib._cec_inverters_path", + ) + def test_load_cec_inverters_database( + self, + mock_cec_inverters_path, + config_eos, + ): + """Test generated inverter database looks sane.""" + + mock_cec_inverters_path.return_value = FILE_TESTDATA_CEC_INVERTERS_PBZ2 + + inverters = _cec_inverters() + + assert "Sungrow__SH25T" in inverters + + inverter = inverters["Sungrow__SH25T"] + + required = [ + "Paco", + "Pdco", + "Vdco", + "Pso", + "Mppt_low", + "Mppt_high", + ] + + for key in required: + assert key in inverter.index + assert pd.notna(inverter[key]), f"{key} is NaN" + + assert inverter["Paco"] > 0 + assert inverter["Pdco"] > 0 + assert inverter["Vdco"] > 0 + assert inverter["Mppt_low"] < inverter["Mppt_high"] + + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib._cec_modules_path", + ) + def test_load_cec_modules_database( + self, + mock_cec_modules_path, + config_eos, + ): + """Test generated module database looks sane.""" + + mock_cec_modules_path.return_value = FILE_TESTDATA_CEC_MODULES_PBZ2 + + modules = _cec_modules() + + assert "AXITEC_AC_410MH_144S" in modules + + module = modules["AXITEC_AC_410MH_144S"] + + # + # Required CEC parameters + # + required = [ + "STC", + "PTC", + "I_sc_ref", + "V_oc_ref", + "I_mp_ref", + "V_mp_ref", + "a_ref", + "I_L_ref", + "I_o_ref", + "R_s", + "R_sh_ref", + "Adjust", + "alpha_sc", + "beta_oc", + "gamma_pmp", + "N_s", + ] + for key in required: + assert key in module.index + assert pd.notna(module[key]), f"{key} is NaN" + + # + # Numeric CEC parameters + # + numeric = [ + "STC", + "I_sc_ref", + "V_oc_ref", + "I_mp_ref", + "V_mp_ref", + "a_ref", + "I_L_ref", + "I_o_ref", + "R_s", + "R_sh_ref", + ] + for key in numeric: + assert isinstance(module[key], (int, float)) + + # + # Physical sanity checks + # + assert module["STC"] > 0 + assert module["PTC"] > 0 + + assert module["V_mp_ref"] > 0 + assert module["I_mp_ref"] > 0 + assert module["V_oc_ref"] > module["V_mp_ref"] + assert module["I_sc_ref"] > module["I_mp_ref"] + + assert module["a_ref"] > 0 + assert module["I_L_ref"] > 0 + assert module["I_o_ref"] > 0 + assert module["R_s"] >= 0 + assert module["R_sh_ref"] > 0 + + # + # STC consistency (within ~5%) + # + assert abs( + module["V_mp_ref"] * module["I_mp_ref"] - module["STC"] + ) < 0.05 * module["STC"] + + +# --------------------------------------------------------------------------- +# Settings +# --------------------------------------------------------------------------- + + +class TestPVForecastPVLibCommonSettings: + """Tests for PVForecastPVLibCommonSettings.""" + + def test_create_settings(self): + """Settings object can be created.""" + settings = PVForecastPVLibCommonSettings() + + assert settings is not None + + +# --------------------------------------------------------------------------- +# Database +# --------------------------------------------------------------------------- + + +class TestCECDatabase: + """Tests for CEC database handling.""" + + def test_modules_database_path(self, config_eos): + """Module database path ends with expected filename.""" + + path = _cec_modules_path() + + assert path.name == "cec_modules.pbz2" + + def test_inverters_database_path(self, config_eos): + """Inverter database path ends with expected filename.""" + + path = _cec_inverters_path() + + assert path.name == "cec_inverters.pbz2" + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.pickle.load", + ) + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.bz2.BZ2File", + ) + def test_load_database( + self, + mock_bz2, + mock_pickle, + tmp_path, + ): + """Database is loaded from pickle.""" + + database = pd.DataFrame({"A": [1]}) + + mock_pickle.return_value = database + + path = tmp_path / "db.pbz2" + + path.touch() + + loaded = _load_cec_database(path) + + assert loaded is database + + mock_pickle.assert_called_once() + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.pickle.load", + ) + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.bz2.BZ2File", + ) + def test_load_database_uses_cache( + self, + mock_bz2, + mock_pickle, + tmp_path, + ): + """Loading same database twice uses memory cache.""" + + database = pd.DataFrame({"A": [1]}) + + mock_pickle.return_value = database + + path = tmp_path / "db.pbz2" + + path.touch() + + db1 = _load_cec_database(path) + db2 = _load_cec_database(path) + + assert db1 is db2 + + mock_pickle.assert_called_once() + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib._update_cec_database", + ) + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.pickle.load", + ) + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.bz2.BZ2File", + ) + def test_missing_database_creates_database( + self, + mock_bz2, + mock_pickle, + mock_update, + tmp_path, + ): + """Missing database triggers recreation.""" + + database = pd.DataFrame({"A": [1]}) + + mock_pickle.return_value = database + + path = tmp_path / "missing.pbz2" + + # + # Simulate creation by update routine. + # + def create_database(): + path.touch() + + mock_update.side_effect = create_database + + loaded = _load_cec_database(path) + + assert loaded is database + + mock_update.assert_called_once() + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.pickle.load", + ) + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.bz2.BZ2File", + ) + def test_cache_contains_loaded_database( + self, + mock_bz2, + mock_pickle, + tmp_path, + ): + """Database is inserted into cache after loading.""" + + database = pd.DataFrame({"A": [1]}) + + mock_pickle.return_value = database + + path = tmp_path / "db.pbz2" + + path.touch() + + _load_cec_database(path) + + assert path in _cec_cache + + _, cached = _cec_cache[path] + + assert cached is database + + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.pickle.load", + ) + @patch( + "akkudoktoreos.prediction.pvforecastpvlib.bz2.BZ2File", + ) + def test_reload_when_timestamp_changes( + self, + mock_bz2, + mock_pickle, + tmp_path, + ): + """Changing mtime forces reload.""" + + db1 = pd.DataFrame({"A": [1]}) + db2 = pd.DataFrame({"A": [2]}) + + mock_pickle.side_effect = [ + db1, + db2, + ] + + path = tmp_path / "db.pbz2" + + path.touch() + + first = _load_cec_database(path) + + # + # Force new modification time. + # + path.touch() + + second = _load_cec_database(path) + + assert first is db1 + assert second is db2 + + assert mock_pickle.call_count == 2 + + +# --------------------------------------------------------------------------- +# Helper methods +# --------------------------------------------------------------------------- + + +class TestHelpers: + """Tests for helper methods.""" + + @pytest.mark.parametrize( + ("device_type", "params", "expected"), + [ + ( + "module", + {"STC": 410.0}, + 410.0, + ), + ( + "module", + { + "I_mp_ref": 10.0, + "V_mp_ref": 40.0, + }, + 400.0, + ), + ( + "inverter", + {"Paco": 5000.0}, + 5000.0, + ), + ( + "inverter", + {"Pdco": 5100.0}, + 5100.0, + ), + ( + "module", + {}, + None, + ), + ( + "inverter", + {}, + None, + ), + ( + "unknown", + {}, + None, + ), + ], + ) + def test_get_model_power( + self, + provider, + device_type, + params, + expected, + ): + """Test extraction of power from model parameters.""" + + assert ( + provider._get_model_power( + params, + device_type, + ) + == expected + ) + + @patch("akkudoktoreos.prediction.pvforecastpvlib.logger.warning") + def test_warn_once(self, mock_warning, provider): + """A warning shall only be logged once.""" + provider._warned_features.clear() + + provider._warn_once("feature1", "test warning") + provider._warn_once("feature1", "test warning") + + mock_warning.assert_called_once_with("test warning") + + @patch("akkudoktoreos.prediction.pvforecastpvlib.logger.warning") + def test_warn_twice_for_different_features(self, mock_warning, provider): + """Different features shall each generate one warning.""" + provider._warned_features.clear() + + provider._warn_once("feature1", "test warning1") + provider._warn_once("feature2", "test warning2") + + assert mock_warning.call_count == 2 + + def test_find_closest_module(self, provider): + """Closest module shall be selected.""" + + database = pd.DataFrame( + { + "ModuleA": { + "STC": 400.0, + }, + "ModuleB": { + "STC": 425.0, + }, + "ModuleC": { + "STC": 600.0, + }, + } + ) + + model = provider._find_closest_model( + 430.0, + database, + "module", + ) + + assert model is not None + assert model.name == "ModuleB" + + def test_find_closest_inverter(self, provider): + """Closest inverter shall be selected.""" + + database = pd.DataFrame( + { + "InvA": { + "Paco": 3000, + }, + "InvB": { + "Paco": 5000, + }, + "InvC": { + "Paco": 8000, + }, + } + ) + + model = provider._find_closest_model( + 5200, + database, + "inverter", + ) + + assert model is not None + assert model.name == "InvB" + + def test_find_closest_returns_none(self, provider): + """No suitable model returns None.""" + + database = pd.DataFrame( + { + "ModuleA": { + "Foo": 1, + }, + "ModuleB": { + "Bar": 2, + }, + } + ) + + model = provider._find_closest_model( + 400, + database, + "module", + ) + + assert model is None + + def test_get_model_by_name(self, provider): + """Retrieve model by exact name.""" + + database = { + "ModuleA": { + "STC": 400, + }, + "ModuleB": { + "STC": 500, + }, + } + + model = provider._get_model( + "ModuleB", + database, + "module", + ) + + assert model["STC"] == 500 + + def test_get_model_by_numeric_string(self, provider): + """Numeric strings shall search nearest model.""" + + database = pd.DataFrame( + { + "ModuleA": { + "STC": 400, + }, + "ModuleB": { + "STC": 450, + }, + } + ) + + model = provider._get_model( + "430", + database, + "module", + ) + + assert model.name == "ModuleB" + + def test_get_model_by_integer(self, provider): + """Integer power shall search nearest model.""" + + database = pd.DataFrame( + { + "ModuleA": { + "STC": 300, + }, + "ModuleB": { + "STC": 420, + }, + } + ) + + model = provider._get_model( + 410, + database, + "module", + ) + + assert model.name == "ModuleB" + + def test_get_model_by_float(self, provider): + """Float power shall search nearest model.""" + + database = pd.DataFrame( + { + "ModuleA": { + "STC": 410.0, + }, + "ModuleB": { + "STC": 600.0, + }, + } + ) + + model = provider._get_model( + 405.0, + database, + "module", + ) + + assert model.name == "ModuleA" + + def test_get_model_invalid_name(self, provider): + """Unknown model names shall raise KeyError.""" + + database = { + "ModuleA": { + "STC": 300, + }, + } + + with pytest.raises(KeyError): + provider._get_model( + "UnknownModule", + database, + "module", + ) + + def test_get_model_invalid_type(self, provider): + """Unsupported model specification returns None.""" + + database: dict = {} + + model = provider._get_model( + ["invalid"], + database, + "module", + ) + + assert model is None + + def test_get_model_empty_database(self, provider): + """Empty database returns None.""" + + database = pd.DataFrame() + + model = provider._find_closest_model( + 400, + database, + "module", + ) + + assert model is None + +# --------------------------------------------------------------------------- +# Static helper methods +# --------------------------------------------------------------------------- + + +class TestStaticMethods: + """Tests for static helper methods.""" + + def test_add_cyclic_hour_features(self): + """Hour sine/cosine features shall be added.""" + + index = pd.date_range( + "2024-06-01", + periods=24, + freq="h", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame(index=index) + + result = PVForecastPVLib.add_cyclic_hour_features(weather) + + assert "hour_sin" in result.columns + assert "hour_cos" in result.columns + + assert len(result) == 24 + + def test_add_cyclic_hour_features_preserves_dataframe(self): + """Original weather columns shall be preserved.""" + + index = pd.date_range( + "2024-06-01", + periods=4, + freq="h", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [100, 200, 300, 400], + "temp_air": [10, 11, 12, 13], + }, + index=index, + ) + + result = PVForecastPVLib.add_cyclic_hour_features(weather) + + assert "ghi" in result.columns + assert "temp_air" in result.columns + assert "hour_sin" in result.columns + assert "hour_cos" in result.columns + + def test_add_cyclic_hour_features_midnight(self): + """Midnight encoding shall be (0,+1).""" + + index = pd.DatetimeIndex( + [ + "2024-06-01 00:00", + ], + tz="Europe/Berlin", + ) + + weather = pd.DataFrame(index=index) + + result = PVForecastPVLib.add_cyclic_hour_features(weather) + + assert abs(result.iloc[0]["hour_sin"]) < 1e-10 + assert result.iloc[0]["hour_cos"] == pytest.approx(1.0) + + def test_add_cyclic_hour_features_noon(self): + """Noon encoding shall be (0,-1).""" + + index = pd.DatetimeIndex( + [ + "2024-06-01 12:00", + ], + tz="Europe/Berlin", + ) + + weather = pd.DataFrame(index=index) + + result = PVForecastPVLib.add_cyclic_hour_features(weather) + + assert abs(result.iloc[0]["hour_sin"]) < 1e-10 + assert result.iloc[0]["hour_cos"] == pytest.approx(-1.0) + + def test_add_cyclic_hour_features_requires_datetimeindex(self): + """DatetimeIndex is required.""" + + weather = pd.DataFrame(index=[0, 1, 2]) + + with pytest.raises( + ValueError, + match="DatetimeIndex", + ): + PVForecastPVLib.add_cyclic_hour_features(weather) + + def test_compute_solar_angles(self): + """Solar angles shall be added.""" + + index = pd.date_range( + "2024-06-01", + periods=8, + freq="h", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame(index=index) + + result = PVForecastPVLib.compute_solar_angles( + weather, + latitude=48.0, + longitude=10.0, + ) + + assert "solar_azimuth" in result.columns + assert "solar_elevation" in result.columns + + assert len(result) == len(weather) + + def test_compute_solar_angles_preserves_columns(self): + """Existing weather columns shall remain.""" + + index = pd.date_range( + "2024-06-01", + periods=3, + freq="h", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [0, 200, 800], + "dni": [0, 150, 700], + }, + index=index, + ) + + result = PVForecastPVLib.compute_solar_angles( + weather, + latitude=48.0, + longitude=10.0, + ) + + assert "ghi" in result.columns + assert "dni" in result.columns + assert "solar_azimuth" in result.columns + assert "solar_elevation" in result.columns + + def test_compute_solar_angles_elevation_range(self): + """Solar elevation shall stay within physical limits.""" + + index = pd.date_range( + "2024-06-01", + periods=24, + freq="h", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame(index=index) + + result = PVForecastPVLib.compute_solar_angles( + weather, + latitude=48.0, + longitude=10.0, + ) + + assert (result["solar_elevation"] <= 90).all() + assert (result["solar_elevation"] >= -90).all() + + def test_compute_solar_angles_azimuth_range(self): + """Solar azimuth shall stay within physical limits.""" + + index = pd.date_range( + "2024-06-01", + periods=24, + freq="h", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame(index=index) + + result = PVForecastPVLib.compute_solar_angles( + weather, + latitude=48.0, + longitude=10.0, + ) + + assert (result["solar_azimuth"] >= 0).all() + assert (result["solar_azimuth"] <= 360).all() + + +# --------------------------------------------------------------------------- +# Provider +# --------------------------------------------------------------------------- + + +class TestProvider: + """Tests for PVForecastPVLib provider.""" + + def test_provider_id(self, provider): + """Provider shall return correct identifier.""" + + assert provider.provider_id() == "PVForecastPVLib" + + def test_singleton_instance(self, provider): + """Provider behaves as singleton.""" + + another = PVForecastPVLib() + + assert provider is another + + def test_enabled(self, config_eos, provider): + """Provider shall be enabled by default.""" + config_eos.pvforecast.provider = "PVForecastPVLib" + + assert provider.enabled() + + def test_disabled_when_wrong_provider( + self, + monkeypatch, + provider, + ): + """Wrong provider name disables provider.""" + + monkeypatch.setenv( + "EOS_PVFORECAST__PVFORECAST_PROVIDER", + "InvalidProvider", + ) + + provider.config.reset_settings() + + assert not provider.enabled() + + @pytest.mark.asyncio + async def test_update_without_planes( + self, + provider, + config_eos, + ): + """No PV planes shall raise.""" + + config_eos.pvforecast.planes = [] + + with pytest.raises( + ValueError, + match="plane", + ): + await provider.update_data( + force_enable=True, + force_update=True, + ) + + @pytest.mark.asyncio + async def test_update_requests_weather_dataframe( + self, + provider, + sample_settings_4planes, + ): + """Weather dataframe shall be requested with correct parameters.""" + + weather = pd.DataFrame() + + + + with patch.object( + Prediction, + "keys_to_dataframe", + return_value=weather, + ) as mock_weather: + + with patch.object( + provider, + "_calculate_pvlib_power", + return_value=pd.DataFrame(columns=["dc", "ac"]), + ): + + await provider.update_data( + force_enable=True, + force_update=True, + ) + + mock_weather.assert_called_once() + + kwargs = mock_weather.call_args.kwargs + + assert kwargs["interval"] == to_duration("15 minutes") + assert kwargs["fill_method"] == "linear" + assert kwargs["resample_method"] == "mean" + assert kwargs["dropna"] is True + assert kwargs["boundary"] == "context" + assert kwargs["align_to_interval"] is True + + @pytest.mark.asyncio + async def test_update_requests_expected_weather_keys( + self, + provider, + sample_settings_4planes, + ): + """Expected weather keys shall be requested.""" + + with patch.object( + Prediction, + "keys_to_dataframe", + return_value=pd.DataFrame(), + ) as mock_weather: + + with patch.object( + provider, + "_calculate_pvlib_power", + return_value=pd.DataFrame(columns=["dc", "ac"]), + ): + + await provider.update_data( + force_enable=True, + force_update=True, + ) + + keys = mock_weather.call_args.kwargs["keys"] + + assert keys == [ + "weather_temp_air", + "weather_relative_humidity", + "weather_preciptable_water", + "weather_total_clouds", + "weather_wind_speed", + "weather_ghi", + "weather_dhi", + "weather_dni", + ] + + @pytest.mark.asyncio + async def test_weather_columns_are_renamed( + self, + provider, + sample_settings_4planes, + ): + """Weather dataframe shall be renamed before calculation.""" + + weather = pd.DataFrame( + { + "weather_temp_air": [20], + "weather_relative_humidity": [60], + "weather_preciptable_water": [2], + "weather_total_clouds": [50], + "weather_wind_speed": [4], + "weather_ghi": [500], + "weather_dhi": [100], + "weather_dni": [600], + } + ) + + with patch.object( + Prediction, + "keys_to_dataframe", + return_value=weather, + ): + + with patch.object( + provider, + "_calculate_pvlib_power", + return_value=pd.DataFrame(columns=["dc", "ac"]), + ) as mock_calc: + + await provider.update_data( + force_enable=True, + force_update=True, + ) + + dataframe = mock_calc.call_args.args[0] + + assert "temp_air" in dataframe.columns + assert "relative_humidity" in dataframe.columns + assert "precipitable_water" in dataframe.columns + assert "cloud_cover" in dataframe.columns + assert "wind_speed" in dataframe.columns + assert "ghi" in dataframe.columns + assert "dhi" in dataframe.columns + assert "dni" in dataframe.columns + + @pytest.mark.asyncio + async def test_calculate_called_once( + self, + provider, + sample_settings_1plane, + ): + """PVLib calculation shall be executed once.""" + + with patch.object( + Prediction, + "keys_to_dataframe", + return_value=pd.DataFrame(), + ): + + with patch.object( + provider, + "_calculate_pvlib_power", + return_value=pd.DataFrame(columns=["dc", "ac"]), + ) as mock_calc: + + await provider.update_data( + force_enable=True, + force_update=True, + ) + + mock_calc.assert_called_once() + + @pytest.mark.asyncio + async def test_update_values_written( + self, + provider, + sample_settings_4planes, + ): + """Calculated values shall be stored.""" + + weather = pd.DataFrame() + + forecast = pd.DataFrame( + { + "pv_dc_power": [1000.0, 1100.0], + "ac_power": [950.0, 1050.0], + }, + index=pd.date_range( + "2024-01-01", + periods=2, + freq="15min", + tz="Europe/Berlin", + ), + ) + + with patch.object( + Prediction, + "keys_to_dataframe", + return_value=weather, + ): + + with patch.object( + provider, + "_calculate_pvlib_power", + return_value=forecast, + ): + + with patch.object( + provider, + "_update_value", + ) as mock_update: + + await provider.update_data( + force_enable=True, + force_update=True, + ) + + assert mock_update.call_count == 4 + + @pytest.mark.asyncio + async def test_empty_forecast( + self, + provider, + sample_settings_4planes, + ): + """Empty forecast shall not write values.""" + + with patch.object( + Prediction, + "keys_to_dataframe", + return_value=pd.DataFrame(), + ): + + with patch.object( + provider, + "_calculate_pvlib_power", + return_value=pd.DataFrame(columns=["dc", "ac"]), + ): + + with patch.object( + provider, + "_update_value", + ) as mock_update: + + await provider.update_data( + force_enable=True, + force_update=True, + ) + + mock_update.assert_not_called() + + +# --------------------------------------------------------------------------- +# PVLib calculation +# --------------------------------------------------------------------------- + + +class TestCalculation: + """Tests for PVLib power calculation.""" + + @pytest.mark.skip("PVLib bails out on empty weather data") + def test_calculate_empty_weather(self, provider, sample_settings_4planes): + """Empty weather dataframe returns empty result.""" + + weather = pd.DataFrame( + columns=[ + "ghi", + "dni", + "dhi", + "temp_air", + "wind_speed", + "relative_humidity", + "precipitable_water", + "cloud_cover", + ], + index=pd.DatetimeIndex([], tz="Europe/Berlin"), + ) + + result = provider._calculate_pvlib_power(weather) + + assert isinstance(result, pd.DataFrame) + assert result.empty + + @patch("akkudoktoreos.prediction.pvforecastpvlib.ModelChain") + @patch("akkudoktoreos.prediction.pvforecastpvlib.Location") + def test_location_created( + self, + mock_location, + mock_modelchain, + provider, + sample_settings_1plane, + ): + """Location shall be created with configured coordinates.""" + + weather = pd.DataFrame( + { + "ghi": [0.0], + "dni": [0.0], + "dhi": [0.0], + "temp_air": [20.0], + "wind_speed": [2.0], + "relative_humidity": [60.0], + "precipitable_water": [1.5], + "cloud_cover": [50.0], + }, + index=pd.date_range( + "2024-06-01", + periods=1, + freq="15min", + tz="Europe/Berlin", + ), + ) + + mc = MagicMock() + mc.results.ac = pd.Series([0.0], index=weather.index) + mc.results.dc = pd.DataFrame( + { + "p_mp": [0.0], + }, + index=weather.index, + ) + mock_modelchain.return_value = mc + + provider._calculate_pvlib_power(weather) + + mock_location.assert_called_once() + + @patch("akkudoktoreos.prediction.pvforecastpvlib.ModelChain") + def test_modelchain_run_called( + self, + mock_modelchain, + provider, + sample_settings_1plane, + ): + """ModelChain.run_model shall be executed.""" + + weather = pd.DataFrame( + { + "ghi": [0.0], + "dni": [0.0], + "dhi": [0.0], + "temp_air": [20.0], + "wind_speed": [2.0], + "relative_humidity": [60.0], + "precipitable_water": [1.5], + "cloud_cover": [50.0], + }, + index=pd.date_range( + "2024-06-01", + periods=1, + freq="15min", + tz="Europe/Berlin", + ), + ) + + mc = MagicMock() + mc.results.ac = pd.Series([0.0], index=weather.index) + mc.results.dc = pd.DataFrame( + { + "p_mp": [0.0], + }, + index=weather.index, + ) + + mock_modelchain.return_value = mc + + provider._calculate_pvlib_power(weather) + + mc.run_model.assert_called_once_with(weather) + + @patch("akkudoktoreos.prediction.pvforecastpvlib.ModelChain") + def test_negative_power_clipped( + self, + mock_modelchain, + provider, + sample_settings_4planes, + ): + """Negative power shall be clipped to zero.""" + + weather = pd.DataFrame( + { + "ghi": [0.0], + "dni": [0.0], + "dhi": [0.0], + "temp_air": [20.0], + "wind_speed": [2.0], + "relative_humidity": [60.0], + "precipitable_water": [1.5], + "cloud_cover": [50.0], + }, + index=pd.date_range( + "2024-06-01", + periods=2, + freq="15min", + tz="Europe/Berlin", + ), + ) + + mc = MagicMock() + + mc.results.dc = pd.DataFrame( + { + "p_mp": [-100.0, 500.0], + }, + index=weather.index, + ) + + mc.results.ac = pd.Series( + [-50.0, 450.0], + index=weather.index, + ) + + mock_modelchain.return_value = mc + + result = provider._calculate_pvlib_power(weather) + + assert (result["pv_dc_power"] >= 0).all() + assert (result["ac_power"] >= 0).all() + + @patch("akkudoktoreos.prediction.pvforecastpvlib.ModelChain") + def test_dataframe_columns( + self, + mock_modelchain, + provider, + sample_settings_4planes, + ): + """Returned dataframe contains expected columns.""" + + weather = pd.DataFrame( + { + "ghi": [0.0], + "dni": [0.0], + "dhi": [0.0], + "temp_air": [20.0], + "wind_speed": [2.0], + "relative_humidity": [60.0], + "precipitable_water": [1.5], + "cloud_cover": [50.0], + }, + index=pd.date_range( + "2024-06-01", + periods=1, + freq="15min", + tz="Europe/Berlin", + ), + ) + + mc = MagicMock() + + mc.results.dc = pd.DataFrame( + { + "p_mp": [1000.0], + }, + index=weather.index, + ) + mc.results.ac = pd.Series([950.0], index=weather.index) + + mock_modelchain.return_value = mc + + result = provider._calculate_pvlib_power(weather) + + assert "pv_dc_power" in result.columns + assert "ac_power" in result.columns + + @patch("akkudoktoreos.prediction.pvforecastpvlib.ModelChain") + def test_result_index_preserved( + self, + mock_modelchain, + provider, + sample_settings_4planes, + ): + """Returned dataframe preserves weather index.""" + + index = pd.date_range( + "2024-06-01", + periods=4, + freq="15min", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [0.0] * 4, + "dni": [0.0] * 4, + "dhi": [0.0] * 4, + "temp_air": [20.0] * 4, + "wind_speed": [2.0] * 4, + "relative_humidity": [60.0] * 4, + "precipitable_water": [1.5] * 4, + "cloud_cover": [50.0] * 4, + }, + index=index, + ) + + mc = MagicMock() + + mc.results.dc = pd.DataFrame( + { + "p_mp": [1.0] * 4, + }, + index=index, + ) + + mc.results.ac = pd.Series( + [1.0] * 4, + index=index, + ) + + mock_modelchain.return_value = mc + + result = provider._calculate_pvlib_power(weather) + + pd.testing.assert_index_equal( + result.index, + weather.index, + ) + + def test_get_model_power_none(self, provider): + """Unknown model parameters return None.""" + + assert provider._get_model_power({}, "module") is None + + def test_find_closest_model_empty(self, provider): + """Empty model database returns None.""" + + model = provider._find_closest_model( + 400, + pd.DataFrame(), + "module", + ) + + assert model is None + + +# --------------------------------------------------------------------------- +# Integration tests +# --------------------------------------------------------------------------- + + +class TestIntegration: + """Integration tests using the real PVLib implementation.""" + + def test_single_plane_produces_power( + self, + provider, + sample_settings_1plane, + ): + """A realistic weather profile shall produce PV power.""" + + index = pd.date_range( + "2024-06-21 08:00", + periods=16, + freq="15min", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [0, 50, 150, 300, 500, 700, 850, 900, + 900, 850, 700, 500, 300, 150, 50, 0], + "dni": [0, 30, 120, 250, 450, 650, 800, 850, + 850, 800, 650, 450, 250, 120, 30, 0], + "dhi": [0, 20, 30, 50, 60, 70, 80, 90, + 90, 80, 70, 60, 50, 30, 20, 0], + "temp_air": [20.0] * 16, + "wind_speed": [2.0] * 16, + "relative_humidity": [55.0] * 16, + "precipitable_water": [1.5] * 16, + "cloud_cover": [10.0] * 16, + }, + index=index, + ) + + result = provider._calculate_pvlib_power(weather) + + assert not result.empty + assert (result["pv_dc_power"] >= 0).all() + assert (result["ac_power"] >= 0).all() + + # + # At least one timestep shall generate power. + # + assert result["pv_dc_power"].max() > 0 + assert result["ac_power"].max() > 0 + + def test_four_planes_generate_more_energy( + self, + provider, + sample_settings_4planes, + ): + """Four PV planes shall produce positive total power.""" + + index = pd.date_range( + "2024-06-21 11:00", + periods=8, + freq="15min", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [900.0] * 8, + "dni": [800.0] * 8, + "dhi": [100.0] * 8, + "temp_air": [25.0] * 8, + "wind_speed": [2.0] * 8, + "relative_humidity": [45.0] * 8, + "precipitable_water": [1.5] * 8, + "cloud_cover": [0.0] * 8, + }, + index=index, + ) + + result = provider._calculate_pvlib_power(weather) + + assert result["pv_dc_power"].sum() > 0 + assert result["ac_power"].sum() > 0 + + def test_zero_irradiance_gives_zero_power( + self, + provider, + sample_settings_1plane, + ): + """No irradiance shall result in zero power.""" + + index = pd.date_range( + "2024-06-21", + periods=8, + freq="15min", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [0.0] * 8, + "dni": [0.0] * 8, + "dhi": [0.0] * 8, + "temp_air": [20.0] * 8, + "wind_speed": [2.0] * 8, + "relative_humidity": [60.0] * 8, + "precipitable_water": [1.5] * 8, + "cloud_cover": [100.0] * 8, + }, + index=index, + ) + + result = provider._calculate_pvlib_power(weather) + + assert result["pv_dc_power"].max() == pytest.approx(0.0) + assert result["ac_power"].max() == pytest.approx(0.0) + + def test_result_preserves_weather_index( + self, + provider, + sample_settings_1plane, + ): + """Returned dataframe shall preserve the weather index.""" + + index = pd.date_range( + "2024-06-21 10:00", + periods=12, + freq="15min", + tz="Europe/Berlin", + ) + + weather = pd.DataFrame( + { + "ghi": [500.0] * 12, + "dni": [450.0] * 12, + "dhi": [50.0] * 12, + "temp_air": [22.0] * 12, + "wind_speed": [2.5] * 12, + "relative_humidity": [50.0] * 12, + "precipitable_water": [1.4] * 12, + "cloud_cover": [15.0] * 12, + }, + index=index, + ) + + # sanity check on module data + module = _cec_modules()[sample_settings_1plane.pvforecast.planes[0].module_model] + assert module["I_o_ref"] > 0 + assert pd.notna(module["a_ref"]) + assert pd.notna(module["R_sh_ref"]) + + result = provider._calculate_pvlib_power(weather) + + pd.testing.assert_index_equal(result.index, weather.index) diff --git a/tests/testdata/docs/_generated/configdevices.md b/tests/testdata/docs/_generated/configdevices.md index a788239e..2fe29f7e 100644 --- a/tests/testdata/docs/_generated/configdevices.md +++ b/tests/testdata/docs/_generated/configdevices.md @@ -209,7 +209,7 @@ | ac_to_dc_efficiency | `float` | `rw` | `1.0` | Efficiency of AC to DC conversion for grid-to-battery AC charging (0-1). Set to 0 to disable AC charging. Default 1.0 (no additional inverter loss). | | battery_id | `str | None` | `rw` | `None` | ID of battery controlled by this inverter. | | dc_to_ac_efficiency | `float` | `rw` | `1.0` | Efficiency of DC to AC conversion for battery discharging to AC load/grid (0-1). Default 1.0 (no additional inverter loss). | -| device_id | `str` | `rw` | `` | ID of device | +| device_id | `str` | `rw` | `required` | ID of device | | max_ac_charge_power_w | `float | None` | `rw` | `None` | Maximum AC charging power in watts. null means no additional limit. Set to 0 to disable AC charging. | | max_power_w | `float | None` | `rw` | `None` | Maximum power [W]. | | measurement_keys | `list[str] | None` | `ro` | `N/A` | Measurement keys for the inverter stati that are measurements. | @@ -372,7 +372,7 @@ as a cohesive unit for scheduling and availability checking. | Name | Type | Read-Only | Default | Description | | ---- | ---- | --------- | ------- | ----------- | | consumption_wh | `int` | `rw` | `required` | Energy consumption [Wh]. | -| device_id | `str` | `rw` | `` | ID of device | +| device_id | `str` | `rw` | `required` | ID of device | | duration_h | `int` | `rw` | `required` | Usage duration in hours [0 ... 24]. | | measurement_keys | `list[str] | None` | `ro` | `N/A` | Measurement keys for the home appliance stati that are measurements. | | time_windows | `akkudoktoreos.config.configabc.TimeWindowSequence | None` | `rw` | `None` | Sequence of allowed time windows. Defaults to optimization general time window. | @@ -454,7 +454,7 @@ as a cohesive unit for scheduling and availability checking. | capacity_wh | `int` | `rw` | `8000` | Capacity [Wh]. | | charge_rates | `list[float] | None` | `rw` | `[0.0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0]` | Charge rates as factor of maximum charging power [0.00 ... 1.00]. None triggers fallback to default charge-rates. | | charging_efficiency | `float` | `rw` | `0.88` | Charging efficiency [0.01 ... 1.00]. | -| device_id | `str` | `rw` | `` | ID of device | +| device_id | `str` | `rw` | `required` | ID of device | | discharging_efficiency | `float` | `rw` | `0.88` | Discharge efficiency [0.01 ... 1.00]. | | levelized_cost_of_storage_kwh | `float` | `rw` | `0.0` | Levelized cost of storage (LCOS), the average lifetime cost of delivering one kWh [amount/kWh]. | | max_charge_power_w | `float | None` | `rw` | `5000` | Maximum charging power [W]. | diff --git a/tests/testdata/docs/_generated/configems.md b/tests/testdata/docs/_generated/configems.md index 5d6ab1e9..10343912 100644 --- a/tests/testdata/docs/_generated/configems.md +++ b/tests/testdata/docs/_generated/configems.md @@ -8,13 +8,14 @@ | Name | Environment Variable | Type | Read-Only | Default | Description | | ---- | -------------------- | ---- | --------- | ------- | ----------- | | interval | `EOS_EMS__INTERVAL` | `float` | `rw` | `300.0` | Intervall between EOS energy management runs [seconds]. | -| mode | `EOS_EMS__MODE` | `` | `rw` | `required` | Energy management mode [DISABLED | OPTIMIZATION | PREDICTION]. | +| mode | `EOS_EMS__MODE` | `` | `rw` | `required` | Energy management mode [DISABLED | PREDICTION | OPTIMIZATION]. Defaults to DISABLED. | +| modes | | `list[str]` | `ro` | `N/A` | Available energy management modes. | | startup_delay | `EOS_EMS__STARTUP_DELAY` | `float` | `rw` | `5` | Startup delay in seconds for EOS energy management runs. | ::: -**Example Input/Output** +**Example Input** @@ -28,3 +29,24 @@ } ``` + + +**Example Output** + + + +```json + { + "ems": { + "startup_delay": 5.0, + "interval": 300.0, + "mode": "OPTIMIZATION", + "modes": [ + "DISABLED", + "PREDICTION", + "OPTIMIZATION" + ] + } + } +``` + diff --git a/tests/testdata/docs/_generated/configexample.md b/tests/testdata/docs/_generated/configexample.md index 235d803c..e48fe468 100644 --- a/tests/testdata/docs/_generated/configexample.md +++ b/tests/testdata/docs/_generated/configexample.md @@ -217,6 +217,7 @@ "token": "your-token", "site_id": 12345 }, + "pvlib": {}, "pvnode": { "api_key": "", "site_id": null, diff --git a/tests/testdata/docs/_generated/configload.md b/tests/testdata/docs/_generated/configload.md index 157e8c32..81e106d0 100644 --- a/tests/testdata/docs/_generated/configload.md +++ b/tests/testdata/docs/_generated/configload.md @@ -63,8 +63,8 @@ "providers": [ "LoadAkkudoktor", "LoadAkkudoktorAdjusted", - "LoadVrm", - "LoadImport" + "LoadImport", + "LoadVrm" ] } } diff --git a/tests/testdata/docs/_generated/configoptimization.md b/tests/testdata/docs/_generated/configoptimization.md index 11c85e72..b12c58fe 100644 --- a/tests/testdata/docs/_generated/configoptimization.md +++ b/tests/testdata/docs/_generated/configoptimization.md @@ -7,7 +7,7 @@ | Name | Environment Variable | Type | Read-Only | Default | Description | | ---- | -------------------- | ---- | --------- | ------- | ----------- | -| algorithm | `EOS_OPTIMIZATION__ALGORITHM` | `str` | `rw` | `GENETIC` | The optimization algorithm. Defaults to GENETIC | +| algorithm | `EOS_OPTIMIZATION__ALGORITHM` | `` | `rw` | `required` | Optimization algorithm [GENETIC | GENETIC0]. Defaults to GENETIC. | | algorithms | | `list[str]` | `ro` | `N/A` | Available optimization algorithms. | | genetic | `EOS_OPTIMIZATION__GENETIC` | `GeneticCommonSettings` | `rw` | `required` | GENETIC optimization algorithm configuration. | | genetic0 | `EOS_OPTIMIZATION__GENETIC0` | `Genetic0CommonSettings` | `rw` | `required` | GENETIC0 optimization algorithm configuration. | diff --git a/tests/testdata/docs/_generated/configpvforecast.md b/tests/testdata/docs/_generated/configpvforecast.md index bd8a75e6..cd9fddab 100644 --- a/tests/testdata/docs/_generated/configpvforecast.md +++ b/tests/testdata/docs/_generated/configpvforecast.md @@ -18,6 +18,7 @@ | provider | `EOS_PVFORECAST__PROVIDER` | `str | None` | `rw` | `None` | PVForecast provider id of provider to be used. | | providers | | `list[str]` | `ro` | `N/A` | Available PVForecast provider ids. | | pvforecastimport | `EOS_PVFORECAST__PVFORECASTIMPORT` | `PVForecastImportCommonSettings` | `rw` | `required` | PV forecast import provider settings | +| pvlib | `EOS_PVFORECAST__PVLIB` | `PVForecastPVLibCommonSettings` | `rw` | `required` | PVLib provider settings | | pvnode | `EOS_PVFORECAST__PVNODE` | `PVForecastPVNodeCommonSettings` | `rw` | `required` | PVNode provider settings | | solcast | `EOS_PVFORECAST__SOLCAST` | `PVForecastSolcastCommonSettings` | `rw` | `required` | Solcast provider settings | | vrm | `EOS_PVFORECAST__VRM` | `PVForecastVrmCommonSettings` | `rw` | `required` | Victron Remote Management (VRM) provider settings | @@ -41,6 +42,7 @@ "token": "your-token", "site_id": 12345 }, + "pvlib": {}, "pvnode": { "api_key": "", "site_id": null, @@ -122,6 +124,7 @@ "token": "your-token", "site_id": 12345 }, + "pvlib": {}, "pvnode": { "api_key": "", "site_id": null, @@ -183,11 +186,12 @@ "max_planes": 1, "providers": [ "PVForecastAkkudoktor", - "PVForecastVrm", - "PVForecastPVNode", "PVForecastForecastSolar", + "PVForecastImport", + "PVForecastPVLib", + "PVForecastPVNode", "PVForecastSolcast", - "PVForecastImport" + "PVForecastVrm" ], "planes_peakpower": [ 5.0, @@ -317,6 +321,32 @@ ``` +### Common settings for pvforecast data calculation with PVLib + + +:::{table} pvforecast::pvlib +:widths: 10 10 5 5 30 +:align: left + +| Name | Type | Read-Only | Default | Description | +| ---- | ---- | --------- | ------- | ----------- | +::: + + + +**Example Input/Output** + + + +```json + { + "pvforecast": { + "pvlib": {} + } + } +``` + + ### Common settings for pvforecast data import from file or JSON string @@ -357,13 +387,13 @@ | Name | Type | Read-Only | Default | Description | | ---- | ---- | --------- | ------- | ----------- | -| albedo | `float | None` | `rw` | `None` | Proportion of the light hitting the ground that it reflects back. | +| albedo | `float | None` | `rw` | `0.2` | Proportion of the light hitting the ground that it reflects back. | | inverter_model | `str | None` | `rw` | `None` | Model of the inverter of this plane. | | inverter_paco | `int | None` | `rw` | `None` | AC power rating of the inverter [W]. | | loss | `float | None` | `rw` | `14.0` | Sum of PV system losses in percent | | module_model | `str | None` | `rw` | `None` | Model of the PV modules of this plane. | | modules_per_string | `int | None` | `rw` | `None` | Number of the PV modules of the strings of this plane. | -| mountingplace | `str | None` | `rw` | `free` | Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated. | +| mountingplace | `str | None` | `rw` | `building` | Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated. | | optimal_surface_tilt | `bool | None` | `rw` | `False` | Calculate the optimum tilt angle. Ignored for two-axis tracking. | | optimalangles | `bool | None` | `rw` | `False` | Calculate the optimum tilt and azimuth angles. Ignored for two-axis tracking. | | peakpower | `float | None` | `rw` | `None` | Nominal power of PV system in kW. | @@ -395,7 +425,7 @@ ], "peakpower": 5.0, "pvtechchoice": "crystSi", - "mountingplace": "free", + "mountingplace": "building", "loss": 14.0, "trackingtype": 0, "optimal_surface_tilt": false, diff --git a/tests/testdata/docs/_generated/configweather.md b/tests/testdata/docs/_generated/configweather.md index 02c94603..ec7d3e05 100644 --- a/tests/testdata/docs/_generated/configweather.md +++ b/tests/testdata/docs/_generated/configweather.md @@ -47,8 +47,8 @@ "providers": [ "BrightSky", "ClearOutside", - "OpenMeteo", - "WeatherImport" + "WeatherImport", + "OpenMeteo" ] } } diff --git a/tests/testdata/pvforecastpvlib/cec_inverters.pbz2 b/tests/testdata/pvforecastpvlib/cec_inverters.pbz2 new file mode 100644 index 00000000..59385c1e Binary files /dev/null and b/tests/testdata/pvforecastpvlib/cec_inverters.pbz2 differ diff --git a/tests/testdata/pvforecastpvlib/cec_modules.pbz2 b/tests/testdata/pvforecastpvlib/cec_modules.pbz2 new file mode 100644 index 00000000..3a9dfd99 Binary files /dev/null and b/tests/testdata/pvforecastpvlib/cec_modules.pbz2 differ