mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-08-31 12:46:38 +00:00
feat: complete 15-minute optimization support
This commit is contained in:
@@ -177,7 +177,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
||||
default_factory=list,
|
||||
json_schema_extra={
|
||||
"description": "Array with battery-to-grid export values (1 for export discharge, 0 otherwise)."
|
||||
}
|
||||
},
|
||||
)
|
||||
eautocharge_hours_float: Optional[list[float]] = Field(json_schema_extra={"description": "TBD"})
|
||||
result: GeneticSimulationResult
|
||||
@@ -331,7 +331,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
||||
Clamping rules:
|
||||
- AC charge factor: scaled down proportionally when the battery
|
||||
headroom (max_soc − current_soc) is smaller than what the
|
||||
commanded factor would store in one hour. Set to 0 when full.
|
||||
commanded factor would store in one optimization slot. Set to 0 when full.
|
||||
- DC charge factor (PV): zeroed when battery is at or above max SOC
|
||||
(the inverter curtails automatically, but this makes intent clear).
|
||||
- Discharge: blocked when SOC is at or below min SOC.
|
||||
@@ -361,9 +361,14 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
||||
if inv_list and inv_list[0].max_ac_charge_power_w is not None
|
||||
else float(bat.max_charge_power_w)
|
||||
)
|
||||
max_dc_per_h_wh = effective_ac * max_ac_cp_w * ac_to_dc_eff * ch_eff
|
||||
if max_dc_per_h_wh > headroom_wh:
|
||||
effective_ac = effective_ac * (headroom_wh / max_dc_per_h_wh)
|
||||
# Energy storable in one optimization slot, not per hour: scale the
|
||||
# power [W] by the slot duration (1.0 hourly, 0.25 at 15 min).
|
||||
slot_duration_h = float(self.config.optimization.interval or 3600) / 3600.0
|
||||
max_dc_per_slot_wh = (
|
||||
effective_ac * max_ac_cp_w * slot_duration_h * ac_to_dc_eff * ch_eff
|
||||
)
|
||||
if max_dc_per_slot_wh > headroom_wh:
|
||||
effective_ac = effective_ac * (headroom_wh / max_dc_per_slot_wh)
|
||||
|
||||
# --- DC charge (PV): zero when battery is full ---
|
||||
effective_dc = dc_charge
|
||||
@@ -619,13 +624,13 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
||||
for pred_key, pred_fill_method, pred_solution_key, pred_solution_factor in [
|
||||
(
|
||||
"pvforecast_ac_power",
|
||||
"linear",
|
||||
"ffill",
|
||||
"pvforecast_ac_energy_wh",
|
||||
power_to_energy_per_interval_factor,
|
||||
),
|
||||
(
|
||||
"pvforecast_dc_power",
|
||||
"linear",
|
||||
"ffill",
|
||||
"pvforecast_dc_energy_wh",
|
||||
power_to_energy_per_interval_factor,
|
||||
),
|
||||
@@ -637,7 +642,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
||||
),
|
||||
(
|
||||
"feed_in_tariff_wh",
|
||||
"linear",
|
||||
"ffill",
|
||||
"feed_in_tariff_amt_kwh",
|
||||
1000.0,
|
||||
),
|
||||
@@ -649,19 +654,19 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
|
||||
),
|
||||
(
|
||||
"loadforecast_power_w",
|
||||
"linear",
|
||||
"ffill",
|
||||
"loadforecast_energy_wh",
|
||||
power_to_energy_per_interval_factor,
|
||||
),
|
||||
(
|
||||
"loadakkudoktor_std_power_w",
|
||||
"linear",
|
||||
"ffill",
|
||||
"loadakkudoktor_std_energy_wh",
|
||||
power_to_energy_per_interval_factor,
|
||||
),
|
||||
(
|
||||
"loadakkudoktor_mean_power_w",
|
||||
"linear",
|
||||
"ffill",
|
||||
"loadakkudoktor_mean_energy_wh",
|
||||
power_to_energy_per_interval_factor,
|
||||
),
|
||||
|
||||
Reference in New Issue