		| @@ -5,34 +5,36 @@ from pprint import pprint | ||||
|  | ||||
|  | ||||
| class Waermepumpe: | ||||
|     MAX_HEIZLEISTUNG = 5000  # Maximum heating power in watts | ||||
|     BASE_HEIZLEISTUNG = 235.0  # Base heating power value | ||||
|     TEMPERATURE_COEFFICIENT = -11.645  # Coefficient for temperature | ||||
|     COP_BASE = 3.0  # Base COP value | ||||
|     COP_COEFFICIENT = 0.1  # COP increase per degree | ||||
|  | ||||
|     def __init__(self, max_heizleistung, prediction_hours): | ||||
|         self.max_heizleistung = max_heizleistung | ||||
|         self.prediction_hours = prediction_hours | ||||
|  | ||||
|     def cop_berechnen(self, aussentemperatur): | ||||
|         cop = 3.0 + (aussentemperatur-0) * 0.1 | ||||
|         """Calculate the coefficient of performance (COP) based on outside temperature.""" | ||||
|         cop = self.COP_BASE + (aussentemperatur * self.COP_COEFFICIENT) | ||||
|         return max(cop, 1) | ||||
|  | ||||
|  | ||||
|     def heizleistung_berechnen(self, aussentemperatur): | ||||
|         #235.092 kWh + Temperatur * -11.645 | ||||
|         heizleistung = (((235.0) + aussentemperatur*(-11.645))*1000)/24.0 | ||||
|         heizleistung = min(self.max_heizleistung,heizleistung) | ||||
|         return heizleistung | ||||
|         """Calculate heating power based on outside temperature.""" | ||||
|         heizleistung = ((self.BASE_HEIZLEISTUNG + aussentemperatur * self.TEMPERATURE_COEFFICIENT) * 1000) / 24.0 | ||||
|         return min(self.max_heizleistung, heizleistung) | ||||
|  | ||||
|     def elektrische_leistung_berechnen(self, aussentemperatur): | ||||
|         #heizleistung = self.heizleistung_berechnen(aussentemperatur) | ||||
|         #cop = self.cop_berechnen(aussentemperatur) | ||||
|          | ||||
|         return 1164  -77.8*aussentemperatur + 1.62*aussentemperatur**2.0 | ||||
|         #1253.0*np.math.pow(aussentemperatur,-0.0682) | ||||
|         """Calculate electrical power based on outside temperature.""" | ||||
|         return 1164 - 77.8 * aussentemperatur + 1.62 * aussentemperatur ** 2.0 | ||||
|  | ||||
|     def simulate_24h(self, temperaturen): | ||||
|         """Simulate power data for 24 hours based on provided temperatures.""" | ||||
|         leistungsdaten = [] | ||||
|  | ||||
|         # Überprüfen, ob das Temperaturarray die richtige Größe hat | ||||
|         if len(temperaturen) != self.prediction_hours: | ||||
|             raise ValueError("Das Temperaturarray muss genau "+str(self.prediction_hours)+" Einträge enthalten, einen für jede Stunde des Tages.") | ||||
|             raise ValueError("The temperature array must contain exactly " + str(self.prediction_hours) + " entries, one for each hour of the day.") | ||||
|          | ||||
|         for temp in temperaturen: | ||||
|             elektrische_leistung = self.elektrische_leistung_berechnen(temp) | ||||
| @@ -40,23 +42,21 @@ class Waermepumpe: | ||||
|         return leistungsdaten | ||||
|  | ||||
|  | ||||
|  | ||||
|  | ||||
|  | ||||
|  | ||||
| # Beispiel für die Verwendung der Klasse | ||||
| # Example usage of the class | ||||
| if __name__ == '__main__': | ||||
|         max_heizleistung = 5000  # 5 kW Heizleistung | ||||
|         start_innentemperatur = 15 | ||||
|         isolationseffizienz = 0.8 | ||||
|         gewuenschte_innentemperatur = 20 | ||||
|         wp = Waermepumpe(max_heizleistung) | ||||
|     max_heizleistung = 5000  # 5 kW heating power | ||||
|     start_innentemperatur = 15  # Initial indoor temperature | ||||
|     isolationseffizienz = 0.8  # Insulation efficiency | ||||
|     gewuenschte_innentemperatur = 20  # Desired indoor temperature | ||||
|     wp = Waermepumpe(max_heizleistung, 24)  # Initialize heat pump with prediction hours | ||||
|  | ||||
|         print(wp.cop_berechnen(-10)," ",wp.cop_berechnen(0), " ", wp.cop_berechnen(10)) | ||||
|         # 24 Stunden Außentemperaturen (Beispielwerte) | ||||
|     # Print COP for various outside temperatures | ||||
|     print(wp.cop_berechnen(-10), " ", wp.cop_berechnen(0), " ", wp.cop_berechnen(10)) | ||||
|  | ||||
|     # 24 hours of outside temperatures (example values) | ||||
|     temperaturen = [10, 9, 8, 7, 6, 5, 4, 3, 2, 1, 0, -1, -2, -3, -4, -5, -6, -7, -8, -9, -10, -5, -2, 5] | ||||
|  | ||||
|         # Berechnung der 24-Stunden-Leistungsdaten | ||||
|     # Calculate the 24-hour power data | ||||
|     leistungsdaten = wp.simulate_24h(temperaturen) | ||||
|  | ||||
|     print(leistungsdaten) | ||||
|   | ||||
		Reference in New Issue
	