@@ -80,9 +80,48 @@ linearly approximated. Storing values between optimization intervals is generall
|
||||
The EOS measurement store automatically sums all given loads to create a total load value series
|
||||
for specified intervals, usually one hour. This aggregated data can be used for load predictions.
|
||||
An interval that the meters do not fully cover (before the first or after the last reading, a meter
|
||||
reset, or a gap longer than the channel's `max_gap_seconds`) has no value instead of zero load; with
|
||||
several load meters, all of them must cover it. Without `max_gap_seconds` a gap between two readings
|
||||
is spread evenly over it. The `LoadAkkudoktorAdjusted` provider skips hours without a value.
|
||||
reset, or a gap longer than the meter's gap limit) has no value instead of zero load; with
|
||||
several load meters, all of them must cover it. The `LoadAkkudoktorAdjusted` provider skips hours
|
||||
without a value.
|
||||
|
||||
### Meter gaps
|
||||
|
||||
The energy between two readings of a `*_emr_keys` meter (load, grid import/export, PV production)
|
||||
is spread evenly over the time between them. A gap longer than `measurement.emr_max_gap_seconds`
|
||||
(default 10800 s, 3 hours) has no energy value instead: an outage of EOS or of the meter does not
|
||||
turn into invented, even consumption or production, nights included.
|
||||
|
||||
```json
|
||||
{
|
||||
"measurement": {
|
||||
"emr_max_gap_seconds": 10800
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
Set it to `null` to spread every gap evenly (the behaviour before the limit). A feeder that only
|
||||
sends a reading when the meter value changes (e.g. a PV or export meter that stands still at night)
|
||||
needs `null` or a value longer than its longest still period; the Home Assistant adapter reads
|
||||
the meters on every energy management run and needs no change.
|
||||
|
||||
A single meter can get its own limit with a `channels` entry, which takes precedence:
|
||||
|
||||
```json
|
||||
{
|
||||
"measurement": {
|
||||
"pv_production_emr_keys": ["pv1_emr"],
|
||||
"channels": {
|
||||
"pv1_emr": {
|
||||
"quantity": "cumulative_energy",
|
||||
"unit": "kWh",
|
||||
"max_gap_seconds": 43200
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
The entry of a `*_emr_keys` meter must stay `cumulative_energy` in `kWh`.
|
||||
|
||||
:::{admonition} Warning
|
||||
:class: warning
|
||||
|
||||
Reference in New Issue