mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 23:16:18 +01:00
feat(measurement): treat long *_emr_keys meter gaps as unknown
Additional fixes: Add timezone to loadakkudoktoradapted tests datetime generation. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
f441759dfa
commit
cc875f798c
@@ -907,10 +907,12 @@ keys in `measurement.pv_production_emr_keys` to fit the model against measuremen
|
||||
Calibration preserves daily energy while optionally correcting the intraday
|
||||
azimuth shape, clamps correction factors and respects inverter capacity.
|
||||
Hourly meters are fitted hourly; native quarter-hour meters retain their cadence.
|
||||
Readings marked invalid or unavailable do not count for the meter cadence.
|
||||
Meters may report at any time stamps: each interval gets the energy interpolated at its
|
||||
boundaries. With several PV meters only the period all of them report is fitted, and
|
||||
intervals a meter does not fully cover (a reset, or a gap longer than the channel's
|
||||
`max_gap_seconds`) are skipped.
|
||||
intervals a meter does not fully cover (a reset, or a gap longer than
|
||||
`measurement.emr_max_gap_seconds` or the channel's `max_gap_seconds`, see the meter gaps
|
||||
in the measurement documentation) are skipped.
|
||||
Probable outage or curtailment days are excluded by default. Without sufficient
|
||||
usable measurements the uncalibrated physical model is used.
|
||||
|
||||
|
||||
Reference in New Issue
Block a user