fix(measurement): use quality-aware meter energy for load and PV
Additional fixes Measurement.meter_energy_kwh converts meter energy over the whole period in one read; the 31-day and 10000-interval limits apply to the public energy queries only. Load intervals a meter does not fully cover are NaN and the load adjustment skips them; load_total_kwh returns an empty array for an empty store and keeps full last intervals. The load adjustment compares over the period the load meters report, skips a stale load meter period and says when no load meter is configured. PV calibration, snow feedback and the load adjustment fall back without measurements when a conversion fails, logged as error once per failure streak and consumer. Measurement.keys_first_datetime and keys_last_datetime find each meter's first and last valid reading in bounded scans, keep each meter's newest reading and return stamps in the configured zone. Measurement.keys_common_period derives the common meter period for PV calibration and the load adjustment and names the meter that ends it, also when meters share no period. PV calibration warns once per stale period when a stopped PV meter holds it on old data; snow feedback warns once about a stale feedback meter. Lasting meter conditions (silent, reset, gap, replaced meter, no shared period) are warned once per condition and consumer through one helper and warned again when they recur. A replaced meter whose readings touch the new one is reported; a single reading is not; a meter group waiting for its second reading is an info once. The PV meter resolution is detected from valid readings only (pre-existing), using one shared valid-reading rule in energy.py. Stale meter stamps are compared with compare_datetimes; new meter tests create durations with datetimeutil. The unused legacy Measurement._energy_from_meter_readings is removed; its test scenarios cover meter_energy_kwh. The converter's range error no longer mentions the API's 31-day limit, and its duplicate interval check is gone. Measurement and prediction docs describe the meter coverage rule, even gap spreading and when the load forecast stays unadjusted. Tests reset the warn-once state of the shared measurement store and restore the EMS start they change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
2bfb6eafab
commit
f441759dfa
@@ -40,6 +40,27 @@ def _date(value: float) -> datetime:
|
||||
return datetime.fromtimestamp(value, timezone.utc)
|
||||
|
||||
|
||||
def valid_reading(value: object, quality: SampleQuality | None = None) -> float | None:
|
||||
"""Value of a raw reading that counts as a valid observation.
|
||||
|
||||
A reading counts when it is a finite number (not a bool) whose sample quality is
|
||||
neither invalid nor unavailable. The energy conversion, the meter period scans
|
||||
and the meter resolution detection share this rule.
|
||||
|
||||
Args:
|
||||
value: Raw stored reading.
|
||||
quality: Sample quality of the reading, None for the default (measured).
|
||||
|
||||
Returns:
|
||||
The reading as float, or None when it does not count.
|
||||
"""
|
||||
if isinstance(value, bool) or not isinstance(value, (int, float)) or not isfinite(value):
|
||||
return None
|
||||
if quality is not None and quality.status in ("invalid", "unavailable"):
|
||||
return None
|
||||
return float(value)
|
||||
|
||||
|
||||
def energy_intervals(
|
||||
samples: Iterable[tuple[datetime, float | None]],
|
||||
channel: "MeasurementChannelSettings",
|
||||
@@ -66,10 +87,9 @@ def energy_intervals(
|
||||
def sample_quality(time: float) -> SampleQuality:
|
||||
return quality.get(time, SampleQuality())
|
||||
|
||||
def number(value: float | None) -> float | None:
|
||||
if isinstance(value, bool) or not isinstance(value, (int, float)) or not isfinite(value):
|
||||
return None
|
||||
return float(value) * scale
|
||||
def number(value: float | None, sample: SampleQuality) -> float | None:
|
||||
reading = valid_reading(value, sample)
|
||||
return None if reading is None else reading * scale
|
||||
|
||||
# Segment: start, end, start/end power in W, method, error flag.
|
||||
segments = []
|
||||
@@ -84,21 +104,15 @@ def energy_intervals(
|
||||
if previous_end is not None and a < previous_end:
|
||||
raise ValueError("Overlapping source energy intervals.")
|
||||
previous_end = b
|
||||
value = number(raw)
|
||||
if sample_quality(time).status in ("invalid", "unavailable"):
|
||||
value = None
|
||||
value = number(raw, sample_quality(time))
|
||||
power = value * 3600 / duration if value is not None else None
|
||||
segments.append(
|
||||
(a, b, power, power, "interval_energy", "invalid_sample" if power is None else None)
|
||||
)
|
||||
else:
|
||||
for (a, raw_a), (b, raw_b) in zip(points, points[1:]):
|
||||
va, vb = number(raw_a), number(raw_b)
|
||||
qa, qb = sample_quality(a), sample_quality(b)
|
||||
if qa.status in ("invalid", "unavailable"):
|
||||
va = None
|
||||
if qb.status in ("invalid", "unavailable"):
|
||||
vb = None
|
||||
va, vb = number(raw_a, qa), number(raw_b, qb)
|
||||
flag = None
|
||||
if channel.max_gap_seconds is not None and b - a > channel.max_gap_seconds:
|
||||
flag = "gap_too_large"
|
||||
|
||||
@@ -8,6 +8,8 @@ The measurements can be added programmatically or imported from a file or JSON s
|
||||
|
||||
import json
|
||||
from bisect import bisect_left, bisect_right
|
||||
from collections.abc import Iterable
|
||||
from dataclasses import dataclass
|
||||
from datetime import datetime, timedelta
|
||||
from pathlib import Path
|
||||
from typing import Any, Callable, Literal, Optional
|
||||
@@ -26,16 +28,36 @@ from akkudoktoreos.measurement.batterycapacity import (
|
||||
BatteryCapacityRequest,
|
||||
estimate_capacity,
|
||||
)
|
||||
from akkudoktoreos.measurement.energy import EnergyInterval
|
||||
from akkudoktoreos.measurement.energy import EnergyInterval, valid_reading
|
||||
from akkudoktoreos.measurement.household import HouseholdSettings, household_intervals
|
||||
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
|
||||
from akkudoktoreos.utils.datetimeutil import (
|
||||
DateTime,
|
||||
Duration,
|
||||
compare_datetimes,
|
||||
to_datetime,
|
||||
to_duration,
|
||||
)
|
||||
|
||||
# Limits of one quality-aware energy query (`Measurement.energy_intervals`).
|
||||
ENERGY_QUERY_MAX_SECONDS = 31 * 86400
|
||||
ENERGY_QUERY_MAX_INTERVALS = 10000
|
||||
|
||||
|
||||
@dataclass(frozen=True)
|
||||
class MeterPeriod:
|
||||
"""Period that every meter of a group reports.
|
||||
|
||||
Attributes:
|
||||
first: Latest first valid reading across the meters.
|
||||
last: Earliest last valid reading across the meters.
|
||||
last_key: Meter whose last reading ends the period.
|
||||
"""
|
||||
|
||||
first: DateTime
|
||||
last: DateTime
|
||||
last_key: str
|
||||
|
||||
|
||||
class MeasurementChannelSettings(SettingsBaseModel):
|
||||
"""Meaning of a raw measurement channel; no conversion is performed on storage."""
|
||||
@@ -209,6 +231,55 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
return
|
||||
super().__init__(*args, **kwargs)
|
||||
|
||||
@property
|
||||
def _reported_warnings(self) -> set[str]:
|
||||
"""Topics of conditions already warned about; see `_warn_once`.
|
||||
|
||||
Created lazily and cached on the instance, like the record locks.
|
||||
"""
|
||||
try:
|
||||
return object.__getattribute__(self, "_reported_warnings_instance")
|
||||
except AttributeError:
|
||||
reported: set[str] = set()
|
||||
object.__setattr__(self, "_reported_warnings_instance", reported)
|
||||
return reported
|
||||
|
||||
def _warn_once(self, topics: str | Iterable[str], message: str, level: str = "WARNING") -> None:
|
||||
"""Log a lasting condition once at ``level``, then as debug until it clears.
|
||||
|
||||
Args:
|
||||
topics: Identity of the condition, e.g. ``"meter-silent:<consumer>:<key>"``;
|
||||
several topics log at ``level`` when any of them is new.
|
||||
message: Log message.
|
||||
level: Log level of the first message.
|
||||
"""
|
||||
topic_set = {topics} if isinstance(topics, str) else set(topics)
|
||||
if topic_set <= self._reported_warnings:
|
||||
logger.debug(message)
|
||||
else:
|
||||
self._reported_warnings.update(topic_set)
|
||||
logger.log(level, message)
|
||||
|
||||
def _clear_warning(self, topic: str) -> None:
|
||||
"""Forget a condition, so it is warned about again when it comes back."""
|
||||
self._reported_warnings.discard(topic)
|
||||
|
||||
def report_conversion_failure(self, consumer: str, message: str) -> None:
|
||||
"""Log a failed meter energy conversion of ``consumer`` once per failure streak.
|
||||
|
||||
The first failure logs as error, repeated failures as debug until
|
||||
`clear_conversion_failure` reports a successful conversion.
|
||||
|
||||
Args:
|
||||
consumer: Conversion path, e.g. ``"LoadAkkudoktorAdjusted"``.
|
||||
message: Log message, including the conversion error.
|
||||
"""
|
||||
self._warn_once(f"conversion-failed:{consumer}", message, level="ERROR")
|
||||
|
||||
def clear_conversion_failure(self, consumer: str) -> None:
|
||||
"""End the failure streak of ``consumer`` after a successful conversion."""
|
||||
self._clear_warning(f"conversion-failed:{consumer}")
|
||||
|
||||
def _measurement_file_path(self) -> Optional[Path]:
|
||||
"""Path to measurements file (may be used optional to database)."""
|
||||
try:
|
||||
@@ -291,14 +362,25 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
start: datetime,
|
||||
end: datetime,
|
||||
) -> Callable[[str, datetime, datetime, int], list[EnergyInterval]]:
|
||||
"""Load a bounded window once, including configured boundary context."""
|
||||
"""Load a window once, including configured boundary context.
|
||||
|
||||
The query limits that protect the API are checked by the public wrappers
|
||||
(`_check_energy_query`), not here.
|
||||
|
||||
Args:
|
||||
keys: Energy channels to convert.
|
||||
start: Start of the window.
|
||||
end: End of the window.
|
||||
|
||||
Returns:
|
||||
Converter from a channel and a sub-window to energy intervals.
|
||||
"""
|
||||
from akkudoktoreos.measurement.energy import energy_intervals
|
||||
|
||||
if any(dt.tzinfo is None or dt.utcoffset() is None for dt in (start, end)):
|
||||
raise ValueError("Explicit timezone required.")
|
||||
seconds = end.timestamp() - start.timestamp()
|
||||
if not 0 < seconds <= 31 * 86400:
|
||||
raise ValueError("Energy queries require a positive range of at most 31 days.")
|
||||
if compare_datetimes(to_datetime(end), to_datetime(start)).le:
|
||||
raise ValueError("Energy queries require a positive range.")
|
||||
channels = {key: self._energy_channel(key) for key in keys}
|
||||
context = self.config.measurement.energy_context_seconds
|
||||
records = [
|
||||
@@ -339,10 +421,6 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
def convert(
|
||||
key: str, left: datetime, right: datetime, interval_seconds: int
|
||||
) -> list[EnergyInterval]:
|
||||
if type(interval_seconds) is not int or interval_seconds <= 0:
|
||||
raise ValueError("Positive integer interval_seconds required.")
|
||||
if (right.timestamp() - left.timestamp()) / interval_seconds > 10000:
|
||||
raise ValueError("At most 10000 output intervals per query.")
|
||||
lo = max(0, bisect_left(timestamps[key], left.timestamp()) - 1)
|
||||
hi = bisect_right(timestamps[key], right.timestamp()) + 1
|
||||
return energy_intervals(
|
||||
@@ -351,6 +429,21 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
|
||||
return convert
|
||||
|
||||
@staticmethod
|
||||
def _check_energy_query(start: datetime, end: datetime, interval_seconds: int) -> None:
|
||||
"""Enforce the limits of one public energy query (31 days, 10000 intervals).
|
||||
|
||||
Raises:
|
||||
ValueError: If the query exceeds a limit.
|
||||
"""
|
||||
seconds = to_datetime(start).diff(to_datetime(end), False).total_seconds()
|
||||
if not 0 < seconds <= ENERGY_QUERY_MAX_SECONDS:
|
||||
raise ValueError("Energy queries require a positive range of at most 31 days.")
|
||||
if type(interval_seconds) is not int or interval_seconds <= 0:
|
||||
raise ValueError("Positive integer interval_seconds required.")
|
||||
if seconds / interval_seconds > ENERGY_QUERY_MAX_INTERVALS:
|
||||
raise ValueError("At most 10000 output intervals per query.")
|
||||
|
||||
async def household_intervals(
|
||||
self, start_datetime: datetime, end_datetime: datetime, interval_seconds: int = 900
|
||||
) -> dict[str, list[EnergyInterval]]:
|
||||
@@ -360,6 +453,7 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
raise ValueError("No household balance configured.")
|
||||
# Revalidate references even after an in-place configuration mutation.
|
||||
settings = HouseholdSettings.model_validate(settings.model_dump())
|
||||
self._check_energy_query(start_datetime, end_datetime, interval_seconds)
|
||||
convert = await self._energy_converter(
|
||||
[item.key for item in settings.inputs], start_datetime, end_datetime
|
||||
)
|
||||
@@ -374,14 +468,243 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
end_datetime: datetime,
|
||||
interval_seconds: int = 900,
|
||||
) -> list[EnergyInterval]:
|
||||
"""Convert a typed channel without changing the legacy kWh calculation.
|
||||
"""Convert a typed channel; load and PV energy use the same conversion.
|
||||
|
||||
Read only explicitly stored values for this key: another channel's timestamp
|
||||
must not introduce a synthetic outage. Explicit null values remain barriers.
|
||||
"""
|
||||
self._check_energy_query(start_datetime, end_datetime, interval_seconds)
|
||||
convert = await self._energy_converter([key], start_datetime, end_datetime)
|
||||
return convert(key, start_datetime, end_datetime, interval_seconds)
|
||||
|
||||
async def meter_energy_kwh(
|
||||
self,
|
||||
keys: list[str],
|
||||
start_datetime: DateTime,
|
||||
end_datetime: DateTime,
|
||||
interval: Duration,
|
||||
) -> dict[str, NDArray[Shape["*"], float]]:
|
||||
"""Energy per interval of energy channels, read from the store once.
|
||||
|
||||
Uses the quality-aware conversion (`energy_intervals`): a cumulative meter is
|
||||
interpolated at the interval boundaries, so a meter reporting at arbitrary
|
||||
stamps yields exactly the energy of each interval. The records of the whole
|
||||
period are loaded once for all channels, so a gap converts the same way
|
||||
wherever it lies in the period.
|
||||
|
||||
Args:
|
||||
keys: Energy channels, e.g. configured meter reading keys.
|
||||
start_datetime: Start of the first interval; intervals start here.
|
||||
end_datetime: End of the period. A last partial interval is extended to a
|
||||
full interval.
|
||||
interval: Interval length, a positive whole number of seconds.
|
||||
|
||||
Returns:
|
||||
Energy in kWh per interval for each key, NaN where the channel does not
|
||||
fully cover the interval (before its first or after its last reading, a
|
||||
reset, or a gap longer than the channel's ``max_gap_seconds``).
|
||||
|
||||
Raises:
|
||||
ValueError: If the period or interval is invalid or a key has no energy
|
||||
channel definition.
|
||||
"""
|
||||
interval_seconds = int(interval.total_seconds())
|
||||
if interval_seconds <= 0 or interval_seconds != interval.total_seconds():
|
||||
raise ValueError("Interval must be a positive whole number of seconds.")
|
||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
||||
if size == 0:
|
||||
return {key: np.zeros(0) for key in keys}
|
||||
period_end = start_datetime.add(seconds=size * interval_seconds)
|
||||
convert = await self._energy_converter(keys, start_datetime, period_end)
|
||||
return {
|
||||
key: np.asarray(
|
||||
[
|
||||
np.nan if slot.energy_wh is None else slot.energy_wh / 1000.0
|
||||
for slot in convert(key, start_datetime, period_end, interval_seconds)
|
||||
],
|
||||
dtype=float,
|
||||
)
|
||||
for key in keys
|
||||
}
|
||||
|
||||
def _valid_reading_keys(self, record: MeasurementDataRecord, keys: Iterable[str]) -> list[str]:
|
||||
"""Keys of ``record`` that carry a valid reading.
|
||||
|
||||
Uses the reading rule of the energy conversion (`valid_reading`).
|
||||
"""
|
||||
if record.date_time is None:
|
||||
return []
|
||||
return [
|
||||
key
|
||||
for key in keys
|
||||
if valid_reading(record.configured_data.get(key), record.sample_quality.get(key))
|
||||
is not None
|
||||
]
|
||||
|
||||
async def keys_valid_datetimes(
|
||||
self, keys: list[str], start_datetime: DateTime, end_datetime: DateTime
|
||||
) -> dict[str, list[DateTime]]:
|
||||
"""Stamps of the valid readings per key in a period, read in one pass.
|
||||
|
||||
Unlike `key_to_lists`, readings whose sample quality is invalid or unavailable
|
||||
do not count (`valid_reading`), as for the energy conversion.
|
||||
|
||||
Args:
|
||||
keys: Record keys, e.g. meter reading keys.
|
||||
start_datetime: Start of the period (inclusive).
|
||||
end_datetime: End of the period (exclusive).
|
||||
|
||||
Returns:
|
||||
Ascending stamps per key, empty for a key without valid readings.
|
||||
"""
|
||||
stamps: dict[str, list[DateTime]] = {key: [] for key in keys}
|
||||
async for record in self.db_iterate_records(
|
||||
DatabaseTimestamp.from_datetime(start_datetime),
|
||||
DatabaseTimestamp.from_datetime(end_datetime),
|
||||
):
|
||||
for key in self._valid_reading_keys(record, keys):
|
||||
stamps[key].append(to_datetime(record.date_time))
|
||||
return stamps
|
||||
|
||||
async def keys_first_datetime(self, keys: list[str]) -> dict[str, DateTime]:
|
||||
"""First stamp with a valid reading per key, in one forward pass.
|
||||
|
||||
Scans forward from the oldest record in windows that double in size and stops
|
||||
once every key is found, instead of reading the keys' whole history.
|
||||
|
||||
Args:
|
||||
keys: Record keys, e.g. meter reading keys.
|
||||
|
||||
Returns:
|
||||
First stamp per key, in the configured timezone like `min_datetime`; keys
|
||||
without a valid reading are missing.
|
||||
"""
|
||||
timezone = self.config.general.timezone
|
||||
wanted = set(keys)
|
||||
firsts: dict[str, DateTime] = {}
|
||||
oldest = await self.min_datetime()
|
||||
newest = await self.max_datetime()
|
||||
if not wanted or oldest is None or newest is None:
|
||||
return firsts
|
||||
end_of_store = newest.add(seconds=1)
|
||||
step_seconds = 86400
|
||||
window_start = oldest
|
||||
while len(firsts) < len(wanted) and compare_datetimes(window_start, end_of_store).lt:
|
||||
window_end = window_start.add(seconds=step_seconds)
|
||||
async for record in self.db_iterate_records(
|
||||
DatabaseTimestamp.from_datetime(window_start),
|
||||
DatabaseTimestamp.from_datetime(window_end),
|
||||
):
|
||||
for key in self._valid_reading_keys(record, wanted - firsts.keys()):
|
||||
firsts[key] = to_datetime(record.date_time, in_timezone=timezone)
|
||||
window_start = window_end
|
||||
step_seconds *= 2
|
||||
return firsts
|
||||
|
||||
async def keys_last_datetime(self, keys: list[str]) -> dict[str, DateTime]:
|
||||
"""Last stamp with a valid reading per key, in one backward pass.
|
||||
|
||||
Scans backward from the newest record in windows that double in size and
|
||||
stops once every key is found.
|
||||
|
||||
Args:
|
||||
keys: Record keys, e.g. meter reading keys.
|
||||
|
||||
Returns:
|
||||
Last stamp per key, in the configured timezone like `max_datetime`; keys
|
||||
without a valid reading are missing.
|
||||
"""
|
||||
timezone = self.config.general.timezone
|
||||
wanted = set(keys)
|
||||
lasts: dict[str, DateTime] = {}
|
||||
oldest = await self.min_datetime()
|
||||
newest = await self.max_datetime()
|
||||
if not wanted or oldest is None or newest is None:
|
||||
return lasts
|
||||
step_seconds = 86400
|
||||
window_end = newest.add(seconds=1)
|
||||
while len(lasts) < len(wanted) and compare_datetimes(window_end, oldest).gt:
|
||||
window_start = window_end.subtract(seconds=step_seconds)
|
||||
# Newest valid reading per key in this window; keys found in a newer
|
||||
# window keep their stamp.
|
||||
window_lasts: dict[str, DateTime] = {}
|
||||
async for record in self.db_iterate_records(
|
||||
DatabaseTimestamp.from_datetime(window_start),
|
||||
DatabaseTimestamp.from_datetime(window_end),
|
||||
):
|
||||
for key in self._valid_reading_keys(record, wanted - lasts.keys()):
|
||||
window_lasts[key] = to_datetime(record.date_time, in_timezone=timezone)
|
||||
lasts.update(window_lasts)
|
||||
window_end = window_start
|
||||
step_seconds *= 2
|
||||
return lasts
|
||||
|
||||
async def keys_common_period(self, keys: list[str], consumer: str) -> Optional[MeterPeriod]:
|
||||
"""Period that every meter in ``keys`` covers with valid readings.
|
||||
|
||||
Outside this period a sum over the meters is not the total they measure.
|
||||
Logs why there is none, once per condition until it clears: a meter without
|
||||
valid readings (e.g. a mistyped key) and meters that share no period (e.g. a
|
||||
replaced meter still configured) are warnings; a single reading so far is an
|
||||
info.
|
||||
|
||||
Args:
|
||||
keys: Meter reading keys of one group, e.g. the PV production meters.
|
||||
consumer: Name used in the log messages and warning topics.
|
||||
|
||||
Returns:
|
||||
The common period, or None when a meter has no valid reading or the meters
|
||||
share no period.
|
||||
"""
|
||||
keys = list(dict.fromkeys(keys))
|
||||
if not keys:
|
||||
return None
|
||||
firsts = await self.keys_first_datetime(keys)
|
||||
silent = [key for key in keys if key not in firsts]
|
||||
for key in firsts:
|
||||
self._clear_warning(f"meter-silent:{consumer}:{key}")
|
||||
if silent:
|
||||
self._warn_once(
|
||||
[f"meter-silent:{consumer}:{key}" for key in silent],
|
||||
f"{consumer}: meter(s) {silent} have no valid readings (check the keys) - "
|
||||
"waiting for them.",
|
||||
)
|
||||
return None
|
||||
lasts = await self.keys_last_datetime(keys)
|
||||
if any(key not in lasts for key in keys):
|
||||
logger.info(f"{consumer}: meter readings changed while reading them - skipping.")
|
||||
return None
|
||||
first_key = keys[0]
|
||||
last_key = keys[0]
|
||||
for key in keys[1:]:
|
||||
if compare_datetimes(firsts[key], firsts[first_key]).gt:
|
||||
first_key = key
|
||||
if compare_datetimes(lasts[key], lasts[last_key]).lt:
|
||||
last_key = key
|
||||
first, last = firsts[first_key], lasts[last_key]
|
||||
overlapping = compare_datetimes(first, last).lt
|
||||
no_period_topic = f"meter-no-period:{consumer}"
|
||||
if not overlapping and first_key != last_key:
|
||||
# Two meters that do not report together, e.g. a replaced meter.
|
||||
self._warn_once(
|
||||
f"{no_period_topic}:{last_key}",
|
||||
f"{consumer}: meter '{last_key}' last reported at {last}, before meter "
|
||||
f"'{first_key}' started at {first} - the meters share no period.",
|
||||
)
|
||||
return None
|
||||
for key in keys:
|
||||
self._clear_warning(f"{no_period_topic}:{key}")
|
||||
if not overlapping:
|
||||
# One meter with a single reading so far (or readings that changed).
|
||||
self._warn_once(
|
||||
f"meter-waiting:{consumer}",
|
||||
f"{consumer}: the meters {keys} have no period yet ({first}) - waiting.",
|
||||
level="INFO",
|
||||
)
|
||||
return None
|
||||
self._clear_warning(f"meter-waiting:{consumer}")
|
||||
return MeterPeriod(first=first, last=last, last_key=last_key)
|
||||
|
||||
async def estimate_battery_capacity(
|
||||
self, battery_id: str, request: BatteryCapacityRequest
|
||||
) -> BatteryCapacityEstimate:
|
||||
@@ -436,90 +759,37 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
discharging_efficiency=parameters.discharging_efficiency,
|
||||
)
|
||||
|
||||
async def _energy_from_meter_readings(
|
||||
self,
|
||||
key: str,
|
||||
start_datetime: DateTime,
|
||||
end_datetime: DateTime,
|
||||
interval: Duration,
|
||||
) -> NDArray[Shape["*"], Any]:
|
||||
"""Calculate an energy values array indexed by fixed time intervals from energy metering data within an optional date range.
|
||||
|
||||
Args:
|
||||
key: Key for energy meter readings.
|
||||
start_datetime (datetime): The start date for filtering the energy data (inclusive).
|
||||
end_datetime (datetime): The end date for filtering the energy data (exclusive).
|
||||
interval (duration): The fixed time interval.
|
||||
|
||||
Returns:
|
||||
np.ndarray: A NumPy Array of the energy [kWh] per interval values calculated from
|
||||
the meter readings.
|
||||
"""
|
||||
if start_datetime is None or end_datetime is None:
|
||||
raise ValueError("Start and end datetimes are required for energy calculation")
|
||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
||||
|
||||
energy_mr_array = await self.key_to_array(
|
||||
key=key,
|
||||
start_datetime=start_datetime,
|
||||
end_datetime=end_datetime + interval,
|
||||
interval=interval,
|
||||
fill_method="time",
|
||||
boundary="context",
|
||||
)
|
||||
if energy_mr_array.size != size + 1:
|
||||
logging_msg = (
|
||||
f"'{key}' meter reading array size: {energy_mr_array.size}"
|
||||
f" does not fit to expected size: {size + 1}, {energy_mr_array}"
|
||||
)
|
||||
if energy_mr_array.size != 0:
|
||||
logger.error(logging_msg)
|
||||
raise ValueError(logging_msg)
|
||||
logger.debug(logging_msg)
|
||||
energy_array = np.zeros(size)
|
||||
elif np.any(energy_mr_array == None):
|
||||
# 'key_to_array()' creates None values array if no data records are available.
|
||||
# Array contains None value -> ignore
|
||||
debug_msg = f"'{key}' meter reading None: {energy_mr_array}"
|
||||
logger.debug(debug_msg)
|
||||
energy_array = np.zeros(size)
|
||||
else:
|
||||
# Calculate load per interval
|
||||
debug_msg = f"'{key}' meter reading: {energy_mr_array}"
|
||||
logger.debug(debug_msg)
|
||||
energy_array = np.diff(energy_mr_array)
|
||||
debug_msg = f"'{key}' energy calculation: {energy_array}"
|
||||
logger.debug(debug_msg)
|
||||
return energy_array
|
||||
|
||||
async def load_total_kwh(
|
||||
self,
|
||||
start_datetime: Optional[DateTime] = None,
|
||||
end_datetime: Optional[DateTime] = None,
|
||||
interval: Optional[Duration] = None,
|
||||
) -> NDArray[Shape["*"], Any]:
|
||||
"""Calculate a total load energy values array indexed by fixed time intervals from load metering data within an optional date range.
|
||||
) -> NDArray[Shape["*"], float]:
|
||||
"""Total load energy per interval from the configured load meters.
|
||||
|
||||
Each meter is converted with `meter_energy_kwh`: the cumulative reading is
|
||||
interpolated at the interval boundaries, and an interval a meter does not
|
||||
fully cover is unknown (NaN), never zero load.
|
||||
|
||||
Args:
|
||||
start_datetime (datetime, optional): The start date for filtering the load data (inclusive).
|
||||
end_datetime (datetime, optional): The end date for filtering the load data (exclusive).
|
||||
start_datetime (datetime, optional): Start of the first interval. Defaults
|
||||
to the first measurement.
|
||||
end_datetime (datetime, optional): End of the period (exclusive). Defaults to
|
||||
just after the last measurement.
|
||||
interval (duration, optional): The fixed time interval. Defaults to 1 hour.
|
||||
|
||||
Returns:
|
||||
np.ndarray: A NumPy Array of the total load energy [kWh] per interval values calculated from
|
||||
the load meter readings.
|
||||
np.ndarray: Total load energy [kWh] per interval; NaN where any load meter
|
||||
lacks full coverage or no load meter is configured.
|
||||
|
||||
Raises:
|
||||
ValueError: If the period cannot be determined or is invalid.
|
||||
"""
|
||||
if interval is None:
|
||||
interval = to_duration("1 hour")
|
||||
|
||||
if len(self) < 1:
|
||||
# No data available
|
||||
if start_datetime is None or end_datetime is None:
|
||||
size = 0
|
||||
else:
|
||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
||||
return np.zeros(size)
|
||||
|
||||
if len(self) < 1 and (start_datetime is None or end_datetime is None):
|
||||
# No data and no period: nothing to report.
|
||||
return np.zeros(0)
|
||||
if start_datetime is None:
|
||||
start_datetime = await self.min_datetime()
|
||||
if end_datetime is None:
|
||||
@@ -529,23 +799,26 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
||||
if start_datetime is None or end_datetime is None:
|
||||
raise ValueError("Start and end datetimes are required for energy calculation")
|
||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
||||
if size == 0:
|
||||
return np.zeros(0)
|
||||
load_keys = self.config.measurement.load_emr_keys or []
|
||||
if not load_keys:
|
||||
return np.full(size, np.nan)
|
||||
|
||||
load_total_kwh_array = np.zeros(size)
|
||||
|
||||
# Loop through all loads
|
||||
if isinstance(self.config.measurement.load_emr_keys, list):
|
||||
for key in self.config.measurement.load_emr_keys:
|
||||
# Calculate load per interval
|
||||
load_array = await self._energy_from_meter_readings(
|
||||
key=key,
|
||||
start_datetime=start_datetime,
|
||||
end_datetime=end_datetime,
|
||||
interval=interval,
|
||||
meters_kwh = await self.meter_energy_kwh(load_keys, start_datetime, end_datetime, interval)
|
||||
for key, meter_kwh in meters_kwh.items():
|
||||
if np.isnan(meter_kwh).all():
|
||||
message = (
|
||||
f"Load meter '{key}' gives no usable energy for {start_datetime} .. "
|
||||
f"{end_datetime} (no readings, resets or gaps longer than its "
|
||||
"max_gap_seconds): the total load of this period is unknown."
|
||||
)
|
||||
# Add calculated load to total load
|
||||
load_total_kwh_array += load_array
|
||||
debug_msg = f"Total load '{key}' calculation: {load_total_kwh_array}"
|
||||
logger.debug(debug_msg)
|
||||
|
||||
self._warn_once(f"meter-unusable:{key}", message)
|
||||
else:
|
||||
self._clear_warning(f"meter-unusable:{key}")
|
||||
load_total_kwh_array += meter_kwh
|
||||
logger.debug(f"Total load calculation: {load_total_kwh_array}")
|
||||
return load_total_kwh_array
|
||||
|
||||