mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 15:06:20 +01:00
fix(measurement): use quality-aware meter energy for load and PV
Additional fixes Measurement.meter_energy_kwh converts meter energy over the whole period in one read; the 31-day and 10000-interval limits apply to the public energy queries only. Load intervals a meter does not fully cover are NaN and the load adjustment skips them; load_total_kwh returns an empty array for an empty store and keeps full last intervals. The load adjustment compares over the period the load meters report, skips a stale load meter period and says when no load meter is configured. PV calibration, snow feedback and the load adjustment fall back without measurements when a conversion fails, logged as error once per failure streak and consumer. Measurement.keys_first_datetime and keys_last_datetime find each meter's first and last valid reading in bounded scans, keep each meter's newest reading and return stamps in the configured zone. Measurement.keys_common_period derives the common meter period for PV calibration and the load adjustment and names the meter that ends it, also when meters share no period. PV calibration warns once per stale period when a stopped PV meter holds it on old data; snow feedback warns once about a stale feedback meter. Lasting meter conditions (silent, reset, gap, replaced meter, no shared period) are warned once per condition and consumer through one helper and warned again when they recur. A replaced meter whose readings touch the new one is reported; a single reading is not; a meter group waiting for its second reading is an info once. The PV meter resolution is detected from valid readings only (pre-existing), using one shared valid-reading rule in energy.py. Stale meter stamps are compared with compare_datetimes; new meter tests create durations with datetimeutil. The unused legacy Measurement._energy_from_meter_readings is removed; its test scenarios cover meter_energy_kwh. The converter's range error no longer mentions the API's 31-day limit, and its duplicate interval check is gone. Measurement and prediction docs describe the meter coverage rule, even gap spreading and when the load forecast stays unadjusted. Tests reset the warn-once state of the shared measurement store and restore the EMS start they change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
2bfb6eafab
commit
f441759dfa
+273
-86
@@ -9,14 +9,17 @@ from pydantic import ValidationError
|
||||
|
||||
from akkudoktoreos.core.coreabc import get_measurement
|
||||
from akkudoktoreos.core.dataabc import DataSequence
|
||||
from akkudoktoreos.core.databaseabc import DatabaseTimestamp
|
||||
from akkudoktoreos.measurement.measurement import (
|
||||
MeasurementChannelSettings,
|
||||
MeasurementCommonSettings,
|
||||
MeasurementDataRecord,
|
||||
)
|
||||
from akkudoktoreos.measurement.quality import SampleQuality
|
||||
from akkudoktoreos.utils.datetimeutil import (
|
||||
compare_datetimes,
|
||||
to_datetime,
|
||||
to_duration,
|
||||
)
|
||||
|
||||
|
||||
@@ -187,6 +190,8 @@ class TestMeasurement:
|
||||
config_eos.measurement.load_emr_keys = ["load0_mr", "load1_mr", "load2_mr", "load3_mr"]
|
||||
measurement = get_measurement()
|
||||
await measurement.delete_by_datetime(None, None)
|
||||
# Warn-once state lives on the shared singleton; start each test fresh.
|
||||
measurement._reported_warnings.clear()
|
||||
record0 = MeasurementDataRecord(
|
||||
date_time=datetime(2023, 1, 1, hour=0),
|
||||
load0_mr=100,
|
||||
@@ -255,109 +260,176 @@ class TestMeasurement:
|
||||
with pytest.raises(ValueError, match="interval must be positive"):
|
||||
measurement_eos._interval_count(start, end, duration(hours=0))
|
||||
|
||||
async def test_energy_from_meter_readings_valid_input(self, measurement_eos):
|
||||
"""Test _energy_from_meter_readings with valid inputs and proper alignment of load data."""
|
||||
key = "load0_mr"
|
||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
interval = duration(hours=1)
|
||||
|
||||
load_array = await measurement_eos._energy_from_meter_readings(
|
||||
key, start_datetime, end_datetime, interval
|
||||
async def test_meter_energy_kwh_valid_input(self, measurement_eos):
|
||||
"""Energy per interval is the difference of the readings at its boundaries."""
|
||||
result = await measurement_eos.meter_energy_kwh(
|
||||
["load0_mr", "load1_mr"],
|
||||
to_datetime("2023-01-01T00:00:00"),
|
||||
to_datetime("2023-01-01T05:00:00"),
|
||||
to_duration("1 hour"),
|
||||
)
|
||||
|
||||
expected_load_array = np.array([50, 50, 50, 50, 50]) # Differences between consecutive readings
|
||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
||||
np.testing.assert_array_equal(result["load0_mr"], [50, 50, 50, 50, 50])
|
||||
np.testing.assert_array_equal(result["load1_mr"], [50, 50, 50, 50, 50])
|
||||
|
||||
async def test_energy_from_meter_readings_empty_array(self, measurement_eos):
|
||||
"""Test _energy_from_meter_readings with no data (empty array)."""
|
||||
key = "load0_mr"
|
||||
async def test_meter_energy_kwh_interpolates_a_missing_reading(self, measurement_eos):
|
||||
"""A reading missing at an interval boundary is interpolated from its neighbours."""
|
||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
interval = duration(hours=1)
|
||||
|
||||
# Use empyt records array
|
||||
await measurement_eos.delete_by_datetime(start_datetime, end_datetime)
|
||||
|
||||
load_array = await measurement_eos._energy_from_meter_readings(
|
||||
key, start_datetime, end_datetime, interval
|
||||
)
|
||||
|
||||
# Expected: an array of zeros with one less than the number of intervals
|
||||
expected_size = (
|
||||
measurement_eos._interval_count(start_datetime, end_datetime + interval, interval) - 1
|
||||
)
|
||||
expected_load_array = np.zeros(expected_size)
|
||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
||||
|
||||
async def test_energy_from_meter_readings_misaligned_array(self, measurement_eos):
|
||||
"""Test _energy_from_meter_readings with misaligned array size."""
|
||||
key = "load1_mr"
|
||||
interval = duration(hours=1)
|
||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
|
||||
# Use misaligned array, latest interval set to 2 hours (instead of 1 hour)
|
||||
latest_record_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
new_record_datetime = to_datetime("2023-01-01T06:00:00")
|
||||
record = await measurement_eos.get_by_datetime(latest_record_datetime)
|
||||
record = await measurement_eos.get_by_datetime(to_datetime("2023-01-01T05:00:00"))
|
||||
assert record is not None
|
||||
await measurement_eos.delete_by_datetime(start_datetime = latest_record_datetime,
|
||||
end_datetime = new_record_datetime)
|
||||
record.date_time = new_record_datetime
|
||||
await measurement_eos.delete_by_datetime(
|
||||
start_datetime=to_datetime("2023-01-01T05:00:00"),
|
||||
end_datetime=to_datetime("2023-01-01T06:00:00"),
|
||||
)
|
||||
record.date_time = to_datetime("2023-01-01T06:00:00")
|
||||
record.load1_mr = 500
|
||||
await measurement_eos.insert_by_datetime(record)
|
||||
|
||||
# Check test setup
|
||||
dates, values = await measurement_eos.key_to_lists(key, start_datetime, None)
|
||||
assert dates == [
|
||||
to_datetime("2023-01-01T00:00:00"),
|
||||
to_datetime("2023-01-01T01:00:00"),
|
||||
to_datetime("2023-01-01T02:00:00"),
|
||||
to_datetime("2023-01-01T03:00:00"),
|
||||
to_datetime("2023-01-01T04:00:00"),
|
||||
to_datetime("2023-01-01T06:00:00"),
|
||||
]
|
||||
assert values == [200, 250, 300, 350, 400, 450]
|
||||
array = await measurement_eos.key_to_array(key, start_datetime, end_datetime + interval, interval=interval)
|
||||
np.testing.assert_array_equal(array, [200, 250, 300, 350, 400, 425])
|
||||
|
||||
load_array = await measurement_eos._energy_from_meter_readings(
|
||||
key, start_datetime, end_datetime, interval
|
||||
result = await measurement_eos.meter_energy_kwh(
|
||||
["load1_mr"], start_datetime, to_datetime("2023-01-01T06:00:00"), to_duration("1 hour")
|
||||
)
|
||||
|
||||
expected_load_array = np.array([50., 50., 50., 50., 25.]) # Differences between consecutive readings
|
||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
||||
np.testing.assert_array_equal(result["load1_mr"], [50.0, 50.0, 50.0, 50.0, 50.0, 50.0])
|
||||
|
||||
async def test_energy_from_meter_readings_partial_data(self, measurement_eos, caplog):
|
||||
"""Test _energy_from_meter_readings with partial data (misaligned but empty array)."""
|
||||
key = "load2_mr"
|
||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
interval = duration(hours=1)
|
||||
async def test_meter_energy_kwh_is_nan_outside_the_readings(self, measurement_eos):
|
||||
"""Intervals before the first or after the last reading are unknown."""
|
||||
result = await measurement_eos.meter_energy_kwh(
|
||||
["load0_mr", "load2_mr"],
|
||||
to_datetime("2022-12-31T23:00:00"),
|
||||
to_datetime("2023-01-01T07:00:00"),
|
||||
to_duration("1 hour"),
|
||||
)
|
||||
|
||||
with caplog.at_level("DEBUG"):
|
||||
load_array = await measurement_eos._energy_from_meter_readings(
|
||||
key, start_datetime, end_datetime, interval
|
||||
np.testing.assert_array_equal(
|
||||
result["load0_mr"], [np.nan, 50, 50, 50, 50, 50, np.nan, np.nan]
|
||||
)
|
||||
assert np.isnan(result["load2_mr"]).all()
|
||||
|
||||
async def test_meter_energy_kwh_extends_a_partial_last_interval(self, measurement_eos):
|
||||
"""A period that ends inside an interval still yields that full interval."""
|
||||
result = await measurement_eos.meter_energy_kwh(
|
||||
["load0_mr"],
|
||||
to_datetime("2023-01-01T00:00:00"),
|
||||
to_datetime("2023-01-01T02:20:00"),
|
||||
to_duration("1 hour"),
|
||||
)
|
||||
|
||||
np.testing.assert_array_equal(result["load0_mr"], [50, 50, 50])
|
||||
|
||||
async def test_meter_energy_kwh_negative_interval(self, measurement_eos):
|
||||
"""A non-positive interval is rejected."""
|
||||
with pytest.raises(ValueError, match="positive whole number of seconds"):
|
||||
await measurement_eos.meter_energy_kwh(
|
||||
["load0_mr"],
|
||||
to_datetime("2023-01-01T00:00:00"),
|
||||
to_datetime("2023-01-01T05:00:00"),
|
||||
to_duration(-3600),
|
||||
)
|
||||
|
||||
expected_size = (
|
||||
measurement_eos._interval_count(start_datetime, end_datetime + interval, interval) - 1
|
||||
async def test_keys_first_and_last_datetime(self, measurement_eos):
|
||||
"""First and last valid reading per key, each key on its own.
|
||||
|
||||
load1_mr reports two days longer than load0_mr, so the backward scan finds the
|
||||
two last readings in different windows; a trailing non-finite value of
|
||||
load0_mr is no reading.
|
||||
"""
|
||||
for hour in range(6, 54):
|
||||
await measurement_eos.update_value(
|
||||
to_datetime("2023-01-01T00:00:00").add(hours=hour), "load1_mr", 450 + hour
|
||||
)
|
||||
await measurement_eos.update_value(
|
||||
to_datetime("2023-01-03T12:00:00"), "load0_mr", float("nan")
|
||||
)
|
||||
expected_load_array = np.zeros(expected_size)
|
||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
||||
keys = ["load0_mr", "load1_mr", "load1_mr", "load2_mr"]
|
||||
|
||||
async def test_energy_from_meter_readings_negative_interval(self, measurement_eos):
|
||||
"""Test _energy_from_meter_readings with a negative interval."""
|
||||
key = "load3_mr"
|
||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
interval = duration(hours=-1)
|
||||
firsts = await measurement_eos.keys_first_datetime(keys)
|
||||
lasts = await measurement_eos.keys_last_datetime(keys)
|
||||
|
||||
with pytest.raises(ValueError, match="interval must be positive"):
|
||||
await measurement_eos._energy_from_meter_readings(key, start_datetime, end_datetime, interval)
|
||||
assert firsts == {
|
||||
"load0_mr": to_datetime("2023-01-01T00:00:00"),
|
||||
"load1_mr": to_datetime("2023-01-01T00:00:00"),
|
||||
}
|
||||
assert lasts == {
|
||||
"load0_mr": to_datetime("2023-01-01T05:00:00"),
|
||||
"load1_mr": to_datetime("2023-01-03T05:00:00"),
|
||||
}
|
||||
timezone = measurement_eos.config.general.timezone
|
||||
assert all(stamp.timezone_name == timezone for stamp in [*firsts.values(), *lasts.values()])
|
||||
|
||||
async def test_conversion_failure_is_logged_once_per_streak(self, measurement_eos, caplog):
|
||||
"""Error on the first failure, debug while it persists, error again after a success."""
|
||||
|
||||
def levels() -> set[str]:
|
||||
levels = {r.levelname for r in caplog.records if "conversion failed" in r.getMessage()}
|
||||
caplog.clear()
|
||||
return levels
|
||||
|
||||
with caplog.at_level("DEBUG"):
|
||||
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
|
||||
assert levels() == {"ERROR"}
|
||||
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
|
||||
assert levels() == {"DEBUG"}
|
||||
# Each consumer has its own streak.
|
||||
measurement_eos.report_conversion_failure("other", "other: conversion failed")
|
||||
assert levels() == {"ERROR"}
|
||||
measurement_eos.clear_conversion_failure("consumer")
|
||||
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
|
||||
assert levels() == {"ERROR"}
|
||||
|
||||
async def test_keys_valid_datetimes(self, measurement_eos):
|
||||
"""Stamps of valid readings in [start, end): invalid quality does not count."""
|
||||
stamp = to_datetime("2023-01-01T02:00:00")
|
||||
record = await measurement_eos.db_get_record(DatabaseTimestamp.from_datetime(stamp))
|
||||
record.sample_quality["load0_mr"] = SampleQuality(status="invalid")
|
||||
await measurement_eos.db_mark_dirty_record(record)
|
||||
|
||||
stamps = await measurement_eos.keys_valid_datetimes(
|
||||
["load0_mr", "load_silent_mr"],
|
||||
to_datetime("2023-01-01T01:00:00"),
|
||||
to_datetime("2023-01-01T04:00:00"),
|
||||
)
|
||||
|
||||
assert stamps == {
|
||||
"load0_mr": [to_datetime("2023-01-01T01:00:00"), to_datetime("2023-01-01T03:00:00")],
|
||||
"load_silent_mr": [],
|
||||
}
|
||||
|
||||
async def test_load_total_kwh_warns_once_about_a_silent_meter(self, measurement_eos, caplog):
|
||||
"""A configured meter that never reports is a warning once, not on every run."""
|
||||
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load_silent_mr"]
|
||||
period = {
|
||||
"start_datetime": to_datetime("2023-01-01T00:00:00"),
|
||||
"end_datetime": to_datetime("2023-01-01T03:00:00"),
|
||||
"interval": to_duration("1 hour"),
|
||||
}
|
||||
|
||||
def silent_meter_warnings() -> int:
|
||||
return sum(
|
||||
record.levelname == "WARNING"
|
||||
and "'load_silent_mr' gives no usable energy" in record.getMessage()
|
||||
for record in caplog.records
|
||||
)
|
||||
|
||||
with caplog.at_level("WARNING"):
|
||||
await measurement_eos.load_total_kwh(**period)
|
||||
first_run = silent_meter_warnings()
|
||||
await measurement_eos.load_total_kwh(**period)
|
||||
|
||||
assert first_run > 0
|
||||
assert silent_meter_warnings() == first_run
|
||||
|
||||
async def test_load_total_kwh_empty_store_without_period(self, measurement_eos):
|
||||
"""No data and no period yields an empty result, not an error."""
|
||||
await measurement_eos.delete_by_datetime(None, None)
|
||||
|
||||
result = await measurement_eos.load_total_kwh()
|
||||
|
||||
assert result.shape == (0,)
|
||||
|
||||
async def test_load_total_kwh(self, measurement_eos):
|
||||
"""Test total load calculation."""
|
||||
# Only these meters report; a silent configured meter makes the total unknown.
|
||||
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||
start_datetime = to_datetime("2023-01-01T03:00:00")
|
||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||
interval = duration(hours=1)
|
||||
@@ -376,11 +448,13 @@ class TestMeasurement:
|
||||
interval = duration(hours=1)
|
||||
|
||||
result = await measurement_eos.load_total_kwh(start_datetime=start_datetime, end_datetime=end_datetime, interval=interval)
|
||||
expected = np.zeros(3) # No data, so all intervals are zero
|
||||
np.testing.assert_array_equal(result, expected)
|
||||
# No data: the load of every interval is unknown, not zero.
|
||||
assert result.shape == (3,)
|
||||
assert np.isnan(result).all()
|
||||
|
||||
async def test_load_total_kwh_partial_intervals(self, measurement_eos):
|
||||
"""Test total load calculation with partial intervals."""
|
||||
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||
start_datetime = to_datetime("2023-01-01T00:30:00") # Start in the middle of an interval
|
||||
end_datetime = to_datetime("2023-01-01T01:30:00") # End in the middle of another interval
|
||||
interval = duration(hours=1)
|
||||
@@ -390,6 +464,60 @@ class TestMeasurement:
|
||||
np.testing.assert_array_equal(result, expected)
|
||||
|
||||
|
||||
async def test_load_total_kwh_follows_a_jittered_meter(self, measurement_eos):
|
||||
"""Hourly load energy is exact for a meter reporting at arbitrary stamps.
|
||||
|
||||
The meter reports every ~5 minutes off the hour. Load is 1 kW until noon and
|
||||
3 kW afterwards; each hour must get exactly its own energy, also around the step.
|
||||
"""
|
||||
measurement_eos.config.measurement.load_emr_keys = ["load_jitter_mr"]
|
||||
start = to_datetime("2023-02-01T00:00:00Z")
|
||||
jitter = [0, 21, 47, 13, 34]
|
||||
stamp = to_datetime("2023-01-31T23:57:10Z")
|
||||
energy_kwh = 0.0
|
||||
step = 0
|
||||
while compare_datetimes(stamp, to_datetime("2023-02-02T00:15:00Z")).lt:
|
||||
await measurement_eos.update_value(stamp, "load_jitter_mr", round(energy_kwh, 6))
|
||||
following = stamp.add(minutes=5, seconds=jitter[step % len(jitter)])
|
||||
noon = to_datetime("2023-02-01T12:00:00Z")
|
||||
seconds_before_noon = max(0.0, min(following.timestamp(), noon.timestamp()) - stamp.timestamp())
|
||||
seconds_after_noon = (following.timestamp() - stamp.timestamp()) - seconds_before_noon
|
||||
energy_kwh += (1.0 * seconds_before_noon + 3.0 * seconds_after_noon) / 3600.0
|
||||
stamp = following
|
||||
step += 1
|
||||
|
||||
result = await measurement_eos.load_total_kwh(
|
||||
start_datetime=start, end_datetime=start.add(days=1), interval=to_duration("1 hour")
|
||||
)
|
||||
|
||||
# Away from the step every hour is exact. The step lies inside one ~5-minute
|
||||
# reading interval, which a meter cannot resolve: hours 11 and 12 share it, but
|
||||
# keep their sum (a bucket-mean conversion moves about half an hour across).
|
||||
np.testing.assert_allclose(result[:11], 1.0, atol=1e-5)
|
||||
np.testing.assert_allclose(result[13:], 3.0, atol=1e-5)
|
||||
assert result[11] == pytest.approx(1.0, abs=0.05)
|
||||
assert result[12] == pytest.approx(3.0, abs=0.05)
|
||||
assert result[11] + result[12] == pytest.approx(4.0, abs=1e-5)
|
||||
|
||||
async def test_load_total_kwh_is_nan_without_full_coverage(self, measurement_eos):
|
||||
"""An hour a load meter does not fully cover is unknown, not zero load."""
|
||||
result = await measurement_eos.load_total_kwh(
|
||||
start_datetime=to_datetime("2023-01-01T03:00:00"),
|
||||
end_datetime=to_datetime("2023-01-01T07:00:00"),
|
||||
interval=to_duration("1 hour"),
|
||||
)
|
||||
|
||||
# load2_mr and load3_mr are configured but never report.
|
||||
assert np.isnan(result).all()
|
||||
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||
result = await measurement_eos.load_total_kwh(
|
||||
start_datetime=to_datetime("2023-01-01T03:00:00"),
|
||||
end_datetime=to_datetime("2023-01-01T07:00:00"),
|
||||
interval=to_duration("1 hour"),
|
||||
)
|
||||
np.testing.assert_array_equal(result, [100.0, 100.0, np.nan, np.nan])
|
||||
|
||||
|
||||
class TestMeasurementFileRestore:
|
||||
@pytest.fixture
|
||||
def file_measurements(self, config_eos, tmp_path, monkeypatch):
|
||||
@@ -546,3 +674,62 @@ class TestMeasurementChannels:
|
||||
measurement.records = previous_records
|
||||
config_eos.measurement = previous_settings
|
||||
config_eos.general.data_folder_path = previous_folder
|
||||
|
||||
|
||||
@pytest.mark.asyncio
|
||||
class TestMeasurementCommonPeriod:
|
||||
"""Common period of a meter group and its warnings."""
|
||||
|
||||
@pytest_asyncio.fixture
|
||||
async def measurement(self, config_eos):
|
||||
# Configured meter keys are writable record keys of the store.
|
||||
config_eos.measurement.load_emr_keys = ["meter_a_mr", "meter_b_mr"]
|
||||
measurement = get_measurement()
|
||||
await measurement.delete_by_datetime(None, None)
|
||||
measurement._reported_warnings.clear()
|
||||
yield measurement
|
||||
await measurement.delete_by_datetime(None, None)
|
||||
measurement._reported_warnings.clear()
|
||||
|
||||
@staticmethod
|
||||
def warnings(caplog, text: str) -> int:
|
||||
return sum(
|
||||
record.levelname == "WARNING" and text in record.getMessage()
|
||||
for record in caplog.records
|
||||
)
|
||||
|
||||
async def test_silent_group_is_warned_again_after_it_reported(self, measurement, caplog):
|
||||
keys = ["meter_a_mr", "meter_b_mr"]
|
||||
start = to_datetime("2024-01-01T00:00:00Z")
|
||||
with caplog.at_level("WARNING"):
|
||||
assert await measurement.keys_common_period(keys, "test") is None
|
||||
first = self.warnings(caplog, "have no valid readings")
|
||||
for hour in range(3):
|
||||
for key in keys:
|
||||
await measurement.update_value(start.add(hours=hour), key, 10.0 + hour)
|
||||
assert await measurement.keys_common_period(keys, "test") is not None
|
||||
await measurement.delete_by_datetime(None, None)
|
||||
assert await measurement.keys_common_period(keys, "test") is None
|
||||
|
||||
assert first > 0
|
||||
assert self.warnings(caplog, "have no valid readings") > first
|
||||
|
||||
async def test_single_reading_is_no_replaced_meter(self, measurement, caplog):
|
||||
await measurement.update_value(to_datetime("2024-01-01T00:00:00Z"), "meter_a_mr", 10.0)
|
||||
|
||||
with caplog.at_level("WARNING"):
|
||||
assert await measurement.keys_common_period(["meter_a_mr"], "test") is None
|
||||
|
||||
assert self.warnings(caplog, "share no period") == 0
|
||||
|
||||
async def test_touching_replacement_is_a_replaced_meter(self, measurement, caplog):
|
||||
"""A swap where the new meter starts at the old meter's last stamp is named."""
|
||||
start = to_datetime("2024-01-01T00:00:00Z")
|
||||
for hour in range(4):
|
||||
await measurement.update_value(start.add(hours=hour), "meter_a_mr", 10.0 + hour)
|
||||
await measurement.update_value(start.add(hours=3 + hour), "meter_b_mr", 50.0 + hour)
|
||||
|
||||
with caplog.at_level("WARNING"):
|
||||
assert await measurement.keys_common_period(["meter_a_mr", "meter_b_mr"], "test") is None
|
||||
|
||||
assert self.warnings(caplog, "meter 'meter_a_mr' last reported at") > 0
|
||||
|
||||
Reference in New Issue