mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 15:06:20 +01:00
fix(measurement): use quality-aware meter energy for load and PV
Additional fixes Measurement.meter_energy_kwh converts meter energy over the whole period in one read; the 31-day and 10000-interval limits apply to the public energy queries only. Load intervals a meter does not fully cover are NaN and the load adjustment skips them; load_total_kwh returns an empty array for an empty store and keeps full last intervals. The load adjustment compares over the period the load meters report, skips a stale load meter period and says when no load meter is configured. PV calibration, snow feedback and the load adjustment fall back without measurements when a conversion fails, logged as error once per failure streak and consumer. Measurement.keys_first_datetime and keys_last_datetime find each meter's first and last valid reading in bounded scans, keep each meter's newest reading and return stamps in the configured zone. Measurement.keys_common_period derives the common meter period for PV calibration and the load adjustment and names the meter that ends it, also when meters share no period. PV calibration warns once per stale period when a stopped PV meter holds it on old data; snow feedback warns once about a stale feedback meter. Lasting meter conditions (silent, reset, gap, replaced meter, no shared period) are warned once per condition and consumer through one helper and warned again when they recur. A replaced meter whose readings touch the new one is reported; a single reading is not; a meter group waiting for its second reading is an info once. The PV meter resolution is detected from valid readings only (pre-existing), using one shared valid-reading rule in energy.py. Stale meter stamps are compared with compare_datetimes; new meter tests create durations with datetimeutil. The unused legacy Measurement._energy_from_meter_readings is removed; its test scenarios cover meter_energy_kwh. The converter's range error no longer mentions the API's 31-day limit, and its duplicate interval check is gone. Measurement and prediction docs describe the meter coverage rule, even gap spreading and when the load forecast stays unadjusted. Tests reset the warn-once state of the shared measurement store and restore the EMS start they change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
2bfb6eafab
commit
f441759dfa
@@ -12,6 +12,7 @@ import pytest_asyncio
|
||||
import requests
|
||||
|
||||
from akkudoktoreos.core.coreabc import get_ems, get_measurement, get_prediction
|
||||
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
|
||||
from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor
|
||||
from akkudoktoreos.prediction.pvforecastakkudoktorlocal import (
|
||||
PVForecastAkkudoktorLocal,
|
||||
@@ -103,6 +104,8 @@ async def pvforecast_instance(config_eos):
|
||||
get_ems().set_start_datetime(START)
|
||||
await provider.delete_by_datetime()
|
||||
await get_measurement().delete_by_datetime()
|
||||
# Warn-once state lives on the shared singleton; start each test fresh.
|
||||
get_measurement()._reported_warnings.clear()
|
||||
yield provider
|
||||
await provider.delete_by_datetime()
|
||||
await get_measurement().delete_by_datetime()
|
||||
@@ -404,6 +407,30 @@ async def test_calibration_uses_real_quarter_hour_measurements(pvforecast_instan
|
||||
assert "15-minute measurement resolution" in caplog.text or "15-minute intervals" in caplog.text
|
||||
|
||||
|
||||
@pytest.mark.asyncio
|
||||
async def test_meter_resolution_counts_valid_readings_only(pvforecast_instance):
|
||||
"""Invalid intrahour readings must not make an hourly meter look quarter-hourly.
|
||||
|
||||
Fitting native slots on such a meter would interpolate within each hour and
|
||||
invent a flat intrahour profile.
|
||||
"""
|
||||
key = "pv_hourly_valid_emr"
|
||||
pvforecast_instance.config.measurement.pv_production_emr_keys = [key]
|
||||
start = START.subtract(days=3)
|
||||
samples = []
|
||||
for slot in range(3 * 24 * 4):
|
||||
stamp = start.add(minutes=15 * slot)
|
||||
quality = (
|
||||
SampleQuality(status="measured") if slot % 4 == 0 else SampleQuality(status="invalid")
|
||||
)
|
||||
samples.append(
|
||||
MeasurementSample(date_time=stamp, key=key, value=float(slot), quality=quality)
|
||||
)
|
||||
await get_measurement().import_samples(samples)
|
||||
|
||||
assert await pvforecast_instance._calibration_interval_minutes(start, START) == 60
|
||||
|
||||
|
||||
@pytest.mark.asyncio
|
||||
async def test_calibration_factor_is_clamped(pvforecast_instance):
|
||||
"""A wildly wrong meter must not be allowed to swing the forecast."""
|
||||
@@ -1059,3 +1086,76 @@ async def test_snow_feedback_window_is_on_the_slot_grid(pvforecast_instance, rec
|
||||
assert end.timestamp() % 900 == 0
|
||||
assert compare_datetimes(end, pv_window.last).le
|
||||
assert compare_datetimes(end.add(minutes=15), pv_window.last).gt
|
||||
|
||||
|
||||
@pytest.mark.asyncio
|
||||
async def test_calibration_falls_back_when_the_meter_conversion_fails(
|
||||
pvforecast_instance, monkeypatch, caplog
|
||||
):
|
||||
"""A broken PV meter history disables calibration instead of the forecast."""
|
||||
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(snow_enabled=True)
|
||||
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
||||
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
||||
await _feed_meters(pvforecast_instance, {"pv_broken_emr": meter})
|
||||
|
||||
async def failing_production_total_kwh(self, start_datetime, end_datetime, interval):
|
||||
raise ValueError("Overlapping source energy intervals.")
|
||||
|
||||
monkeypatch.setattr(
|
||||
PVForecastAkkudoktorLocal, "_pv_production_total_kwh", failing_production_total_kwh
|
||||
)
|
||||
|
||||
with caplog.at_level("ERROR"):
|
||||
forecast = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
||||
calibration = await _fit(pvforecast_instance, frame)
|
||||
|
||||
assert calibration is None
|
||||
np.testing.assert_allclose(forecast["ac_power"], frame["ac_power"])
|
||||
assert "calibration: PV meter energy conversion failed" in caplog.text
|
||||
|
||||
|
||||
@pytest.mark.asyncio
|
||||
async def test_calibration_warns_about_a_stale_common_meter_period(pvforecast_instance, caplog):
|
||||
"""A PV meter that stopped reporting holds the fit on old data - say so."""
|
||||
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
||||
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
||||
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
||||
await _feed_meters(pvforecast_instance, {"pv_stale_emr": meter})
|
||||
|
||||
def stale_warnings() -> int:
|
||||
return sum(
|
||||
record.levelname == "WARNING"
|
||||
and "meter 'pv_stale_emr' last reported at" in record.getMessage()
|
||||
for record in caplog.records
|
||||
)
|
||||
|
||||
with caplog.at_level("WARNING"):
|
||||
get_ems().set_start_datetime(START.add(hours=12))
|
||||
await _fit(pvforecast_instance, frame)
|
||||
fresh = stale_warnings()
|
||||
get_ems().set_start_datetime(START.add(days=3))
|
||||
calibration = await _fit(pvforecast_instance, frame)
|
||||
first_stale_run = stale_warnings()
|
||||
await _fit(pvforecast_instance, frame)
|
||||
|
||||
_assert_fitted_bias(calibration, 0.8)
|
||||
assert fresh == 0
|
||||
assert first_stale_run > 0
|
||||
# Once per stale period, not on every run.
|
||||
assert stale_warnings() == first_stale_run
|
||||
|
||||
|
||||
@pytest.mark.asyncio
|
||||
async def test_pv_meter_window_skips_readings_that_vanish_between_scans(
|
||||
pvforecast_instance, monkeypatch
|
||||
):
|
||||
"""Readings removed between the first and last scan give no window, not an error."""
|
||||
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
||||
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
||||
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
||||
await _feed_meters(pvforecast_instance, {"pv_vanishing_emr": meter})
|
||||
monkeypatch.setattr(
|
||||
type(get_measurement()), "keys_last_datetime", AsyncMock(return_value={})
|
||||
)
|
||||
|
||||
assert await pvforecast_instance._pv_measurement_window() is None
|
||||
|
||||
Reference in New Issue