mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 15:06:20 +01:00
fix(measurement): use quality-aware meter energy for load and PV
Additional fixes Measurement.meter_energy_kwh converts meter energy over the whole period in one read; the 31-day and 10000-interval limits apply to the public energy queries only. Load intervals a meter does not fully cover are NaN and the load adjustment skips them; load_total_kwh returns an empty array for an empty store and keeps full last intervals. The load adjustment compares over the period the load meters report, skips a stale load meter period and says when no load meter is configured. PV calibration, snow feedback and the load adjustment fall back without measurements when a conversion fails, logged as error once per failure streak and consumer. Measurement.keys_first_datetime and keys_last_datetime find each meter's first and last valid reading in bounded scans, keep each meter's newest reading and return stamps in the configured zone. Measurement.keys_common_period derives the common meter period for PV calibration and the load adjustment and names the meter that ends it, also when meters share no period. PV calibration warns once per stale period when a stopped PV meter holds it on old data; snow feedback warns once about a stale feedback meter. Lasting meter conditions (silent, reset, gap, replaced meter, no shared period) are warned once per condition and consumer through one helper and warned again when they recur. A replaced meter whose readings touch the new one is reported; a single reading is not; a meter group waiting for its second reading is an info once. The PV meter resolution is detected from valid readings only (pre-existing), using one shared valid-reading rule in energy.py. Stale meter stamps are compared with compare_datetimes; new meter tests create durations with datetimeutil. The unused legacy Measurement._energy_from_meter_readings is removed; its test scenarios cover meter_energy_kwh. The converter's range error no longer mentions the API's 31-day limit, and its duplicate interval check is gone. Measurement and prediction docs describe the meter coverage rule, even gap spreading and when the load forecast stays unadjusted. Tests reset the warn-once state of the shared measurement store and restore the EMS start they change. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
2bfb6eafab
commit
f441759dfa
@@ -79,6 +79,10 @@ linearly approximated. Storing values between optimization intervals is generall
|
|||||||
|
|
||||||
The EOS measurement store automatically sums all given loads to create a total load value series
|
The EOS measurement store automatically sums all given loads to create a total load value series
|
||||||
for specified intervals, usually one hour. This aggregated data can be used for load predictions.
|
for specified intervals, usually one hour. This aggregated data can be used for load predictions.
|
||||||
|
An interval that the meters do not fully cover (before the first or after the last reading, a meter
|
||||||
|
reset, or a gap longer than the channel's `max_gap_seconds`) has no value instead of zero load; with
|
||||||
|
several load meters, all of them must cover it. Without `max_gap_seconds` a gap between two readings
|
||||||
|
is spread evenly over it. The `LoadAkkudoktorAdjusted` provider skips hours without a value.
|
||||||
|
|
||||||
:::{admonition} Warning
|
:::{admonition} Warning
|
||||||
:class: warning
|
:class: warning
|
||||||
|
|||||||
@@ -579,7 +579,9 @@ The `LoadAkkudoktorAdjusted` provider retrieves generic load data from the local
|
|||||||
it to match the annual energy consumption specified in the
|
it to match the annual energy consumption specified in the
|
||||||
`LoadAkkudoktor.loadakkudoktor_year_energy` configuration option. In addition, the provider refines
|
`LoadAkkudoktor.loadakkudoktor_year_energy` configuration option. In addition, the provider refines
|
||||||
the forecast by incorporating available measured load data, ensuring a more realistic and
|
the forecast by incorporating available measured load data, ensuring a more realistic and
|
||||||
site-specific consumption profile.
|
site-specific consumption profile. It compares the last 7 days that every configured load meter
|
||||||
|
reports; if a load meter has no readings or stopped reporting more than 7 days ago, the forecast
|
||||||
|
stays unadjusted and a warning names the meter.
|
||||||
|
|
||||||
Prediction keys:
|
Prediction keys:
|
||||||
|
|
||||||
@@ -905,6 +907,10 @@ keys in `measurement.pv_production_emr_keys` to fit the model against measuremen
|
|||||||
Calibration preserves daily energy while optionally correcting the intraday
|
Calibration preserves daily energy while optionally correcting the intraday
|
||||||
azimuth shape, clamps correction factors and respects inverter capacity.
|
azimuth shape, clamps correction factors and respects inverter capacity.
|
||||||
Hourly meters are fitted hourly; native quarter-hour meters retain their cadence.
|
Hourly meters are fitted hourly; native quarter-hour meters retain their cadence.
|
||||||
|
Meters may report at any time stamps: each interval gets the energy interpolated at its
|
||||||
|
boundaries. With several PV meters only the period all of them report is fitted, and
|
||||||
|
intervals a meter does not fully cover (a reset, or a gap longer than the channel's
|
||||||
|
`max_gap_seconds`) are skipped.
|
||||||
Probable outage or curtailment days are excluded by default. Without sufficient
|
Probable outage or curtailment days are excluded by default. Without sufficient
|
||||||
usable measurements the uncalibrated physical model is used.
|
usable measurements the uncalibrated physical model is used.
|
||||||
|
|
||||||
|
|||||||
@@ -40,6 +40,27 @@ def _date(value: float) -> datetime:
|
|||||||
return datetime.fromtimestamp(value, timezone.utc)
|
return datetime.fromtimestamp(value, timezone.utc)
|
||||||
|
|
||||||
|
|
||||||
|
def valid_reading(value: object, quality: SampleQuality | None = None) -> float | None:
|
||||||
|
"""Value of a raw reading that counts as a valid observation.
|
||||||
|
|
||||||
|
A reading counts when it is a finite number (not a bool) whose sample quality is
|
||||||
|
neither invalid nor unavailable. The energy conversion, the meter period scans
|
||||||
|
and the meter resolution detection share this rule.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
value: Raw stored reading.
|
||||||
|
quality: Sample quality of the reading, None for the default (measured).
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
The reading as float, or None when it does not count.
|
||||||
|
"""
|
||||||
|
if isinstance(value, bool) or not isinstance(value, (int, float)) or not isfinite(value):
|
||||||
|
return None
|
||||||
|
if quality is not None and quality.status in ("invalid", "unavailable"):
|
||||||
|
return None
|
||||||
|
return float(value)
|
||||||
|
|
||||||
|
|
||||||
def energy_intervals(
|
def energy_intervals(
|
||||||
samples: Iterable[tuple[datetime, float | None]],
|
samples: Iterable[tuple[datetime, float | None]],
|
||||||
channel: "MeasurementChannelSettings",
|
channel: "MeasurementChannelSettings",
|
||||||
@@ -66,10 +87,9 @@ def energy_intervals(
|
|||||||
def sample_quality(time: float) -> SampleQuality:
|
def sample_quality(time: float) -> SampleQuality:
|
||||||
return quality.get(time, SampleQuality())
|
return quality.get(time, SampleQuality())
|
||||||
|
|
||||||
def number(value: float | None) -> float | None:
|
def number(value: float | None, sample: SampleQuality) -> float | None:
|
||||||
if isinstance(value, bool) or not isinstance(value, (int, float)) or not isfinite(value):
|
reading = valid_reading(value, sample)
|
||||||
return None
|
return None if reading is None else reading * scale
|
||||||
return float(value) * scale
|
|
||||||
|
|
||||||
# Segment: start, end, start/end power in W, method, error flag.
|
# Segment: start, end, start/end power in W, method, error flag.
|
||||||
segments = []
|
segments = []
|
||||||
@@ -84,21 +104,15 @@ def energy_intervals(
|
|||||||
if previous_end is not None and a < previous_end:
|
if previous_end is not None and a < previous_end:
|
||||||
raise ValueError("Overlapping source energy intervals.")
|
raise ValueError("Overlapping source energy intervals.")
|
||||||
previous_end = b
|
previous_end = b
|
||||||
value = number(raw)
|
value = number(raw, sample_quality(time))
|
||||||
if sample_quality(time).status in ("invalid", "unavailable"):
|
|
||||||
value = None
|
|
||||||
power = value * 3600 / duration if value is not None else None
|
power = value * 3600 / duration if value is not None else None
|
||||||
segments.append(
|
segments.append(
|
||||||
(a, b, power, power, "interval_energy", "invalid_sample" if power is None else None)
|
(a, b, power, power, "interval_energy", "invalid_sample" if power is None else None)
|
||||||
)
|
)
|
||||||
else:
|
else:
|
||||||
for (a, raw_a), (b, raw_b) in zip(points, points[1:]):
|
for (a, raw_a), (b, raw_b) in zip(points, points[1:]):
|
||||||
va, vb = number(raw_a), number(raw_b)
|
|
||||||
qa, qb = sample_quality(a), sample_quality(b)
|
qa, qb = sample_quality(a), sample_quality(b)
|
||||||
if qa.status in ("invalid", "unavailable"):
|
va, vb = number(raw_a, qa), number(raw_b, qb)
|
||||||
va = None
|
|
||||||
if qb.status in ("invalid", "unavailable"):
|
|
||||||
vb = None
|
|
||||||
flag = None
|
flag = None
|
||||||
if channel.max_gap_seconds is not None and b - a > channel.max_gap_seconds:
|
if channel.max_gap_seconds is not None and b - a > channel.max_gap_seconds:
|
||||||
flag = "gap_too_large"
|
flag = "gap_too_large"
|
||||||
|
|||||||
@@ -8,6 +8,8 @@ The measurements can be added programmatically or imported from a file or JSON s
|
|||||||
|
|
||||||
import json
|
import json
|
||||||
from bisect import bisect_left, bisect_right
|
from bisect import bisect_left, bisect_right
|
||||||
|
from collections.abc import Iterable
|
||||||
|
from dataclasses import dataclass
|
||||||
from datetime import datetime, timedelta
|
from datetime import datetime, timedelta
|
||||||
from pathlib import Path
|
from pathlib import Path
|
||||||
from typing import Any, Callable, Literal, Optional
|
from typing import Any, Callable, Literal, Optional
|
||||||
@@ -26,16 +28,36 @@ from akkudoktoreos.measurement.batterycapacity import (
|
|||||||
BatteryCapacityRequest,
|
BatteryCapacityRequest,
|
||||||
estimate_capacity,
|
estimate_capacity,
|
||||||
)
|
)
|
||||||
from akkudoktoreos.measurement.energy import EnergyInterval
|
from akkudoktoreos.measurement.energy import EnergyInterval, valid_reading
|
||||||
from akkudoktoreos.measurement.household import HouseholdSettings, household_intervals
|
from akkudoktoreos.measurement.household import HouseholdSettings, household_intervals
|
||||||
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
|
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
|
||||||
from akkudoktoreos.utils.datetimeutil import (
|
from akkudoktoreos.utils.datetimeutil import (
|
||||||
DateTime,
|
DateTime,
|
||||||
Duration,
|
Duration,
|
||||||
|
compare_datetimes,
|
||||||
to_datetime,
|
to_datetime,
|
||||||
to_duration,
|
to_duration,
|
||||||
)
|
)
|
||||||
|
|
||||||
|
# Limits of one quality-aware energy query (`Measurement.energy_intervals`).
|
||||||
|
ENERGY_QUERY_MAX_SECONDS = 31 * 86400
|
||||||
|
ENERGY_QUERY_MAX_INTERVALS = 10000
|
||||||
|
|
||||||
|
|
||||||
|
@dataclass(frozen=True)
|
||||||
|
class MeterPeriod:
|
||||||
|
"""Period that every meter of a group reports.
|
||||||
|
|
||||||
|
Attributes:
|
||||||
|
first: Latest first valid reading across the meters.
|
||||||
|
last: Earliest last valid reading across the meters.
|
||||||
|
last_key: Meter whose last reading ends the period.
|
||||||
|
"""
|
||||||
|
|
||||||
|
first: DateTime
|
||||||
|
last: DateTime
|
||||||
|
last_key: str
|
||||||
|
|
||||||
|
|
||||||
class MeasurementChannelSettings(SettingsBaseModel):
|
class MeasurementChannelSettings(SettingsBaseModel):
|
||||||
"""Meaning of a raw measurement channel; no conversion is performed on storage."""
|
"""Meaning of a raw measurement channel; no conversion is performed on storage."""
|
||||||
@@ -209,6 +231,55 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
return
|
return
|
||||||
super().__init__(*args, **kwargs)
|
super().__init__(*args, **kwargs)
|
||||||
|
|
||||||
|
@property
|
||||||
|
def _reported_warnings(self) -> set[str]:
|
||||||
|
"""Topics of conditions already warned about; see `_warn_once`.
|
||||||
|
|
||||||
|
Created lazily and cached on the instance, like the record locks.
|
||||||
|
"""
|
||||||
|
try:
|
||||||
|
return object.__getattribute__(self, "_reported_warnings_instance")
|
||||||
|
except AttributeError:
|
||||||
|
reported: set[str] = set()
|
||||||
|
object.__setattr__(self, "_reported_warnings_instance", reported)
|
||||||
|
return reported
|
||||||
|
|
||||||
|
def _warn_once(self, topics: str | Iterable[str], message: str, level: str = "WARNING") -> None:
|
||||||
|
"""Log a lasting condition once at ``level``, then as debug until it clears.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
topics: Identity of the condition, e.g. ``"meter-silent:<consumer>:<key>"``;
|
||||||
|
several topics log at ``level`` when any of them is new.
|
||||||
|
message: Log message.
|
||||||
|
level: Log level of the first message.
|
||||||
|
"""
|
||||||
|
topic_set = {topics} if isinstance(topics, str) else set(topics)
|
||||||
|
if topic_set <= self._reported_warnings:
|
||||||
|
logger.debug(message)
|
||||||
|
else:
|
||||||
|
self._reported_warnings.update(topic_set)
|
||||||
|
logger.log(level, message)
|
||||||
|
|
||||||
|
def _clear_warning(self, topic: str) -> None:
|
||||||
|
"""Forget a condition, so it is warned about again when it comes back."""
|
||||||
|
self._reported_warnings.discard(topic)
|
||||||
|
|
||||||
|
def report_conversion_failure(self, consumer: str, message: str) -> None:
|
||||||
|
"""Log a failed meter energy conversion of ``consumer`` once per failure streak.
|
||||||
|
|
||||||
|
The first failure logs as error, repeated failures as debug until
|
||||||
|
`clear_conversion_failure` reports a successful conversion.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
consumer: Conversion path, e.g. ``"LoadAkkudoktorAdjusted"``.
|
||||||
|
message: Log message, including the conversion error.
|
||||||
|
"""
|
||||||
|
self._warn_once(f"conversion-failed:{consumer}", message, level="ERROR")
|
||||||
|
|
||||||
|
def clear_conversion_failure(self, consumer: str) -> None:
|
||||||
|
"""End the failure streak of ``consumer`` after a successful conversion."""
|
||||||
|
self._clear_warning(f"conversion-failed:{consumer}")
|
||||||
|
|
||||||
def _measurement_file_path(self) -> Optional[Path]:
|
def _measurement_file_path(self) -> Optional[Path]:
|
||||||
"""Path to measurements file (may be used optional to database)."""
|
"""Path to measurements file (may be used optional to database)."""
|
||||||
try:
|
try:
|
||||||
@@ -291,14 +362,25 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
start: datetime,
|
start: datetime,
|
||||||
end: datetime,
|
end: datetime,
|
||||||
) -> Callable[[str, datetime, datetime, int], list[EnergyInterval]]:
|
) -> Callable[[str, datetime, datetime, int], list[EnergyInterval]]:
|
||||||
"""Load a bounded window once, including configured boundary context."""
|
"""Load a window once, including configured boundary context.
|
||||||
|
|
||||||
|
The query limits that protect the API are checked by the public wrappers
|
||||||
|
(`_check_energy_query`), not here.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
keys: Energy channels to convert.
|
||||||
|
start: Start of the window.
|
||||||
|
end: End of the window.
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
Converter from a channel and a sub-window to energy intervals.
|
||||||
|
"""
|
||||||
from akkudoktoreos.measurement.energy import energy_intervals
|
from akkudoktoreos.measurement.energy import energy_intervals
|
||||||
|
|
||||||
if any(dt.tzinfo is None or dt.utcoffset() is None for dt in (start, end)):
|
if any(dt.tzinfo is None or dt.utcoffset() is None for dt in (start, end)):
|
||||||
raise ValueError("Explicit timezone required.")
|
raise ValueError("Explicit timezone required.")
|
||||||
seconds = end.timestamp() - start.timestamp()
|
if compare_datetimes(to_datetime(end), to_datetime(start)).le:
|
||||||
if not 0 < seconds <= 31 * 86400:
|
raise ValueError("Energy queries require a positive range.")
|
||||||
raise ValueError("Energy queries require a positive range of at most 31 days.")
|
|
||||||
channels = {key: self._energy_channel(key) for key in keys}
|
channels = {key: self._energy_channel(key) for key in keys}
|
||||||
context = self.config.measurement.energy_context_seconds
|
context = self.config.measurement.energy_context_seconds
|
||||||
records = [
|
records = [
|
||||||
@@ -339,10 +421,6 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
def convert(
|
def convert(
|
||||||
key: str, left: datetime, right: datetime, interval_seconds: int
|
key: str, left: datetime, right: datetime, interval_seconds: int
|
||||||
) -> list[EnergyInterval]:
|
) -> list[EnergyInterval]:
|
||||||
if type(interval_seconds) is not int or interval_seconds <= 0:
|
|
||||||
raise ValueError("Positive integer interval_seconds required.")
|
|
||||||
if (right.timestamp() - left.timestamp()) / interval_seconds > 10000:
|
|
||||||
raise ValueError("At most 10000 output intervals per query.")
|
|
||||||
lo = max(0, bisect_left(timestamps[key], left.timestamp()) - 1)
|
lo = max(0, bisect_left(timestamps[key], left.timestamp()) - 1)
|
||||||
hi = bisect_right(timestamps[key], right.timestamp()) + 1
|
hi = bisect_right(timestamps[key], right.timestamp()) + 1
|
||||||
return energy_intervals(
|
return energy_intervals(
|
||||||
@@ -351,6 +429,21 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
|
|
||||||
return convert
|
return convert
|
||||||
|
|
||||||
|
@staticmethod
|
||||||
|
def _check_energy_query(start: datetime, end: datetime, interval_seconds: int) -> None:
|
||||||
|
"""Enforce the limits of one public energy query (31 days, 10000 intervals).
|
||||||
|
|
||||||
|
Raises:
|
||||||
|
ValueError: If the query exceeds a limit.
|
||||||
|
"""
|
||||||
|
seconds = to_datetime(start).diff(to_datetime(end), False).total_seconds()
|
||||||
|
if not 0 < seconds <= ENERGY_QUERY_MAX_SECONDS:
|
||||||
|
raise ValueError("Energy queries require a positive range of at most 31 days.")
|
||||||
|
if type(interval_seconds) is not int or interval_seconds <= 0:
|
||||||
|
raise ValueError("Positive integer interval_seconds required.")
|
||||||
|
if seconds / interval_seconds > ENERGY_QUERY_MAX_INTERVALS:
|
||||||
|
raise ValueError("At most 10000 output intervals per query.")
|
||||||
|
|
||||||
async def household_intervals(
|
async def household_intervals(
|
||||||
self, start_datetime: datetime, end_datetime: datetime, interval_seconds: int = 900
|
self, start_datetime: datetime, end_datetime: datetime, interval_seconds: int = 900
|
||||||
) -> dict[str, list[EnergyInterval]]:
|
) -> dict[str, list[EnergyInterval]]:
|
||||||
@@ -360,6 +453,7 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
raise ValueError("No household balance configured.")
|
raise ValueError("No household balance configured.")
|
||||||
# Revalidate references even after an in-place configuration mutation.
|
# Revalidate references even after an in-place configuration mutation.
|
||||||
settings = HouseholdSettings.model_validate(settings.model_dump())
|
settings = HouseholdSettings.model_validate(settings.model_dump())
|
||||||
|
self._check_energy_query(start_datetime, end_datetime, interval_seconds)
|
||||||
convert = await self._energy_converter(
|
convert = await self._energy_converter(
|
||||||
[item.key for item in settings.inputs], start_datetime, end_datetime
|
[item.key for item in settings.inputs], start_datetime, end_datetime
|
||||||
)
|
)
|
||||||
@@ -374,14 +468,243 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
end_datetime: datetime,
|
end_datetime: datetime,
|
||||||
interval_seconds: int = 900,
|
interval_seconds: int = 900,
|
||||||
) -> list[EnergyInterval]:
|
) -> list[EnergyInterval]:
|
||||||
"""Convert a typed channel without changing the legacy kWh calculation.
|
"""Convert a typed channel; load and PV energy use the same conversion.
|
||||||
|
|
||||||
Read only explicitly stored values for this key: another channel's timestamp
|
Read only explicitly stored values for this key: another channel's timestamp
|
||||||
must not introduce a synthetic outage. Explicit null values remain barriers.
|
must not introduce a synthetic outage. Explicit null values remain barriers.
|
||||||
"""
|
"""
|
||||||
|
self._check_energy_query(start_datetime, end_datetime, interval_seconds)
|
||||||
convert = await self._energy_converter([key], start_datetime, end_datetime)
|
convert = await self._energy_converter([key], start_datetime, end_datetime)
|
||||||
return convert(key, start_datetime, end_datetime, interval_seconds)
|
return convert(key, start_datetime, end_datetime, interval_seconds)
|
||||||
|
|
||||||
|
async def meter_energy_kwh(
|
||||||
|
self,
|
||||||
|
keys: list[str],
|
||||||
|
start_datetime: DateTime,
|
||||||
|
end_datetime: DateTime,
|
||||||
|
interval: Duration,
|
||||||
|
) -> dict[str, NDArray[Shape["*"], float]]:
|
||||||
|
"""Energy per interval of energy channels, read from the store once.
|
||||||
|
|
||||||
|
Uses the quality-aware conversion (`energy_intervals`): a cumulative meter is
|
||||||
|
interpolated at the interval boundaries, so a meter reporting at arbitrary
|
||||||
|
stamps yields exactly the energy of each interval. The records of the whole
|
||||||
|
period are loaded once for all channels, so a gap converts the same way
|
||||||
|
wherever it lies in the period.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
keys: Energy channels, e.g. configured meter reading keys.
|
||||||
|
start_datetime: Start of the first interval; intervals start here.
|
||||||
|
end_datetime: End of the period. A last partial interval is extended to a
|
||||||
|
full interval.
|
||||||
|
interval: Interval length, a positive whole number of seconds.
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
Energy in kWh per interval for each key, NaN where the channel does not
|
||||||
|
fully cover the interval (before its first or after its last reading, a
|
||||||
|
reset, or a gap longer than the channel's ``max_gap_seconds``).
|
||||||
|
|
||||||
|
Raises:
|
||||||
|
ValueError: If the period or interval is invalid or a key has no energy
|
||||||
|
channel definition.
|
||||||
|
"""
|
||||||
|
interval_seconds = int(interval.total_seconds())
|
||||||
|
if interval_seconds <= 0 or interval_seconds != interval.total_seconds():
|
||||||
|
raise ValueError("Interval must be a positive whole number of seconds.")
|
||||||
|
size = self._interval_count(start_datetime, end_datetime, interval)
|
||||||
|
if size == 0:
|
||||||
|
return {key: np.zeros(0) for key in keys}
|
||||||
|
period_end = start_datetime.add(seconds=size * interval_seconds)
|
||||||
|
convert = await self._energy_converter(keys, start_datetime, period_end)
|
||||||
|
return {
|
||||||
|
key: np.asarray(
|
||||||
|
[
|
||||||
|
np.nan if slot.energy_wh is None else slot.energy_wh / 1000.0
|
||||||
|
for slot in convert(key, start_datetime, period_end, interval_seconds)
|
||||||
|
],
|
||||||
|
dtype=float,
|
||||||
|
)
|
||||||
|
for key in keys
|
||||||
|
}
|
||||||
|
|
||||||
|
def _valid_reading_keys(self, record: MeasurementDataRecord, keys: Iterable[str]) -> list[str]:
|
||||||
|
"""Keys of ``record`` that carry a valid reading.
|
||||||
|
|
||||||
|
Uses the reading rule of the energy conversion (`valid_reading`).
|
||||||
|
"""
|
||||||
|
if record.date_time is None:
|
||||||
|
return []
|
||||||
|
return [
|
||||||
|
key
|
||||||
|
for key in keys
|
||||||
|
if valid_reading(record.configured_data.get(key), record.sample_quality.get(key))
|
||||||
|
is not None
|
||||||
|
]
|
||||||
|
|
||||||
|
async def keys_valid_datetimes(
|
||||||
|
self, keys: list[str], start_datetime: DateTime, end_datetime: DateTime
|
||||||
|
) -> dict[str, list[DateTime]]:
|
||||||
|
"""Stamps of the valid readings per key in a period, read in one pass.
|
||||||
|
|
||||||
|
Unlike `key_to_lists`, readings whose sample quality is invalid or unavailable
|
||||||
|
do not count (`valid_reading`), as for the energy conversion.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
keys: Record keys, e.g. meter reading keys.
|
||||||
|
start_datetime: Start of the period (inclusive).
|
||||||
|
end_datetime: End of the period (exclusive).
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
Ascending stamps per key, empty for a key without valid readings.
|
||||||
|
"""
|
||||||
|
stamps: dict[str, list[DateTime]] = {key: [] for key in keys}
|
||||||
|
async for record in self.db_iterate_records(
|
||||||
|
DatabaseTimestamp.from_datetime(start_datetime),
|
||||||
|
DatabaseTimestamp.from_datetime(end_datetime),
|
||||||
|
):
|
||||||
|
for key in self._valid_reading_keys(record, keys):
|
||||||
|
stamps[key].append(to_datetime(record.date_time))
|
||||||
|
return stamps
|
||||||
|
|
||||||
|
async def keys_first_datetime(self, keys: list[str]) -> dict[str, DateTime]:
|
||||||
|
"""First stamp with a valid reading per key, in one forward pass.
|
||||||
|
|
||||||
|
Scans forward from the oldest record in windows that double in size and stops
|
||||||
|
once every key is found, instead of reading the keys' whole history.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
keys: Record keys, e.g. meter reading keys.
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
First stamp per key, in the configured timezone like `min_datetime`; keys
|
||||||
|
without a valid reading are missing.
|
||||||
|
"""
|
||||||
|
timezone = self.config.general.timezone
|
||||||
|
wanted = set(keys)
|
||||||
|
firsts: dict[str, DateTime] = {}
|
||||||
|
oldest = await self.min_datetime()
|
||||||
|
newest = await self.max_datetime()
|
||||||
|
if not wanted or oldest is None or newest is None:
|
||||||
|
return firsts
|
||||||
|
end_of_store = newest.add(seconds=1)
|
||||||
|
step_seconds = 86400
|
||||||
|
window_start = oldest
|
||||||
|
while len(firsts) < len(wanted) and compare_datetimes(window_start, end_of_store).lt:
|
||||||
|
window_end = window_start.add(seconds=step_seconds)
|
||||||
|
async for record in self.db_iterate_records(
|
||||||
|
DatabaseTimestamp.from_datetime(window_start),
|
||||||
|
DatabaseTimestamp.from_datetime(window_end),
|
||||||
|
):
|
||||||
|
for key in self._valid_reading_keys(record, wanted - firsts.keys()):
|
||||||
|
firsts[key] = to_datetime(record.date_time, in_timezone=timezone)
|
||||||
|
window_start = window_end
|
||||||
|
step_seconds *= 2
|
||||||
|
return firsts
|
||||||
|
|
||||||
|
async def keys_last_datetime(self, keys: list[str]) -> dict[str, DateTime]:
|
||||||
|
"""Last stamp with a valid reading per key, in one backward pass.
|
||||||
|
|
||||||
|
Scans backward from the newest record in windows that double in size and
|
||||||
|
stops once every key is found.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
keys: Record keys, e.g. meter reading keys.
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
Last stamp per key, in the configured timezone like `max_datetime`; keys
|
||||||
|
without a valid reading are missing.
|
||||||
|
"""
|
||||||
|
timezone = self.config.general.timezone
|
||||||
|
wanted = set(keys)
|
||||||
|
lasts: dict[str, DateTime] = {}
|
||||||
|
oldest = await self.min_datetime()
|
||||||
|
newest = await self.max_datetime()
|
||||||
|
if not wanted or oldest is None or newest is None:
|
||||||
|
return lasts
|
||||||
|
step_seconds = 86400
|
||||||
|
window_end = newest.add(seconds=1)
|
||||||
|
while len(lasts) < len(wanted) and compare_datetimes(window_end, oldest).gt:
|
||||||
|
window_start = window_end.subtract(seconds=step_seconds)
|
||||||
|
# Newest valid reading per key in this window; keys found in a newer
|
||||||
|
# window keep their stamp.
|
||||||
|
window_lasts: dict[str, DateTime] = {}
|
||||||
|
async for record in self.db_iterate_records(
|
||||||
|
DatabaseTimestamp.from_datetime(window_start),
|
||||||
|
DatabaseTimestamp.from_datetime(window_end),
|
||||||
|
):
|
||||||
|
for key in self._valid_reading_keys(record, wanted - lasts.keys()):
|
||||||
|
window_lasts[key] = to_datetime(record.date_time, in_timezone=timezone)
|
||||||
|
lasts.update(window_lasts)
|
||||||
|
window_end = window_start
|
||||||
|
step_seconds *= 2
|
||||||
|
return lasts
|
||||||
|
|
||||||
|
async def keys_common_period(self, keys: list[str], consumer: str) -> Optional[MeterPeriod]:
|
||||||
|
"""Period that every meter in ``keys`` covers with valid readings.
|
||||||
|
|
||||||
|
Outside this period a sum over the meters is not the total they measure.
|
||||||
|
Logs why there is none, once per condition until it clears: a meter without
|
||||||
|
valid readings (e.g. a mistyped key) and meters that share no period (e.g. a
|
||||||
|
replaced meter still configured) are warnings; a single reading so far is an
|
||||||
|
info.
|
||||||
|
|
||||||
|
Args:
|
||||||
|
keys: Meter reading keys of one group, e.g. the PV production meters.
|
||||||
|
consumer: Name used in the log messages and warning topics.
|
||||||
|
|
||||||
|
Returns:
|
||||||
|
The common period, or None when a meter has no valid reading or the meters
|
||||||
|
share no period.
|
||||||
|
"""
|
||||||
|
keys = list(dict.fromkeys(keys))
|
||||||
|
if not keys:
|
||||||
|
return None
|
||||||
|
firsts = await self.keys_first_datetime(keys)
|
||||||
|
silent = [key for key in keys if key not in firsts]
|
||||||
|
for key in firsts:
|
||||||
|
self._clear_warning(f"meter-silent:{consumer}:{key}")
|
||||||
|
if silent:
|
||||||
|
self._warn_once(
|
||||||
|
[f"meter-silent:{consumer}:{key}" for key in silent],
|
||||||
|
f"{consumer}: meter(s) {silent} have no valid readings (check the keys) - "
|
||||||
|
"waiting for them.",
|
||||||
|
)
|
||||||
|
return None
|
||||||
|
lasts = await self.keys_last_datetime(keys)
|
||||||
|
if any(key not in lasts for key in keys):
|
||||||
|
logger.info(f"{consumer}: meter readings changed while reading them - skipping.")
|
||||||
|
return None
|
||||||
|
first_key = keys[0]
|
||||||
|
last_key = keys[0]
|
||||||
|
for key in keys[1:]:
|
||||||
|
if compare_datetimes(firsts[key], firsts[first_key]).gt:
|
||||||
|
first_key = key
|
||||||
|
if compare_datetimes(lasts[key], lasts[last_key]).lt:
|
||||||
|
last_key = key
|
||||||
|
first, last = firsts[first_key], lasts[last_key]
|
||||||
|
overlapping = compare_datetimes(first, last).lt
|
||||||
|
no_period_topic = f"meter-no-period:{consumer}"
|
||||||
|
if not overlapping and first_key != last_key:
|
||||||
|
# Two meters that do not report together, e.g. a replaced meter.
|
||||||
|
self._warn_once(
|
||||||
|
f"{no_period_topic}:{last_key}",
|
||||||
|
f"{consumer}: meter '{last_key}' last reported at {last}, before meter "
|
||||||
|
f"'{first_key}' started at {first} - the meters share no period.",
|
||||||
|
)
|
||||||
|
return None
|
||||||
|
for key in keys:
|
||||||
|
self._clear_warning(f"{no_period_topic}:{key}")
|
||||||
|
if not overlapping:
|
||||||
|
# One meter with a single reading so far (or readings that changed).
|
||||||
|
self._warn_once(
|
||||||
|
f"meter-waiting:{consumer}",
|
||||||
|
f"{consumer}: the meters {keys} have no period yet ({first}) - waiting.",
|
||||||
|
level="INFO",
|
||||||
|
)
|
||||||
|
return None
|
||||||
|
self._clear_warning(f"meter-waiting:{consumer}")
|
||||||
|
return MeterPeriod(first=first, last=last, last_key=last_key)
|
||||||
|
|
||||||
async def estimate_battery_capacity(
|
async def estimate_battery_capacity(
|
||||||
self, battery_id: str, request: BatteryCapacityRequest
|
self, battery_id: str, request: BatteryCapacityRequest
|
||||||
) -> BatteryCapacityEstimate:
|
) -> BatteryCapacityEstimate:
|
||||||
@@ -436,90 +759,37 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
discharging_efficiency=parameters.discharging_efficiency,
|
discharging_efficiency=parameters.discharging_efficiency,
|
||||||
)
|
)
|
||||||
|
|
||||||
async def _energy_from_meter_readings(
|
|
||||||
self,
|
|
||||||
key: str,
|
|
||||||
start_datetime: DateTime,
|
|
||||||
end_datetime: DateTime,
|
|
||||||
interval: Duration,
|
|
||||||
) -> NDArray[Shape["*"], Any]:
|
|
||||||
"""Calculate an energy values array indexed by fixed time intervals from energy metering data within an optional date range.
|
|
||||||
|
|
||||||
Args:
|
|
||||||
key: Key for energy meter readings.
|
|
||||||
start_datetime (datetime): The start date for filtering the energy data (inclusive).
|
|
||||||
end_datetime (datetime): The end date for filtering the energy data (exclusive).
|
|
||||||
interval (duration): The fixed time interval.
|
|
||||||
|
|
||||||
Returns:
|
|
||||||
np.ndarray: A NumPy Array of the energy [kWh] per interval values calculated from
|
|
||||||
the meter readings.
|
|
||||||
"""
|
|
||||||
if start_datetime is None or end_datetime is None:
|
|
||||||
raise ValueError("Start and end datetimes are required for energy calculation")
|
|
||||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
|
||||||
|
|
||||||
energy_mr_array = await self.key_to_array(
|
|
||||||
key=key,
|
|
||||||
start_datetime=start_datetime,
|
|
||||||
end_datetime=end_datetime + interval,
|
|
||||||
interval=interval,
|
|
||||||
fill_method="time",
|
|
||||||
boundary="context",
|
|
||||||
)
|
|
||||||
if energy_mr_array.size != size + 1:
|
|
||||||
logging_msg = (
|
|
||||||
f"'{key}' meter reading array size: {energy_mr_array.size}"
|
|
||||||
f" does not fit to expected size: {size + 1}, {energy_mr_array}"
|
|
||||||
)
|
|
||||||
if energy_mr_array.size != 0:
|
|
||||||
logger.error(logging_msg)
|
|
||||||
raise ValueError(logging_msg)
|
|
||||||
logger.debug(logging_msg)
|
|
||||||
energy_array = np.zeros(size)
|
|
||||||
elif np.any(energy_mr_array == None):
|
|
||||||
# 'key_to_array()' creates None values array if no data records are available.
|
|
||||||
# Array contains None value -> ignore
|
|
||||||
debug_msg = f"'{key}' meter reading None: {energy_mr_array}"
|
|
||||||
logger.debug(debug_msg)
|
|
||||||
energy_array = np.zeros(size)
|
|
||||||
else:
|
|
||||||
# Calculate load per interval
|
|
||||||
debug_msg = f"'{key}' meter reading: {energy_mr_array}"
|
|
||||||
logger.debug(debug_msg)
|
|
||||||
energy_array = np.diff(energy_mr_array)
|
|
||||||
debug_msg = f"'{key}' energy calculation: {energy_array}"
|
|
||||||
logger.debug(debug_msg)
|
|
||||||
return energy_array
|
|
||||||
|
|
||||||
async def load_total_kwh(
|
async def load_total_kwh(
|
||||||
self,
|
self,
|
||||||
start_datetime: Optional[DateTime] = None,
|
start_datetime: Optional[DateTime] = None,
|
||||||
end_datetime: Optional[DateTime] = None,
|
end_datetime: Optional[DateTime] = None,
|
||||||
interval: Optional[Duration] = None,
|
interval: Optional[Duration] = None,
|
||||||
) -> NDArray[Shape["*"], Any]:
|
) -> NDArray[Shape["*"], float]:
|
||||||
"""Calculate a total load energy values array indexed by fixed time intervals from load metering data within an optional date range.
|
"""Total load energy per interval from the configured load meters.
|
||||||
|
|
||||||
|
Each meter is converted with `meter_energy_kwh`: the cumulative reading is
|
||||||
|
interpolated at the interval boundaries, and an interval a meter does not
|
||||||
|
fully cover is unknown (NaN), never zero load.
|
||||||
|
|
||||||
Args:
|
Args:
|
||||||
start_datetime (datetime, optional): The start date for filtering the load data (inclusive).
|
start_datetime (datetime, optional): Start of the first interval. Defaults
|
||||||
end_datetime (datetime, optional): The end date for filtering the load data (exclusive).
|
to the first measurement.
|
||||||
|
end_datetime (datetime, optional): End of the period (exclusive). Defaults to
|
||||||
|
just after the last measurement.
|
||||||
interval (duration, optional): The fixed time interval. Defaults to 1 hour.
|
interval (duration, optional): The fixed time interval. Defaults to 1 hour.
|
||||||
|
|
||||||
Returns:
|
Returns:
|
||||||
np.ndarray: A NumPy Array of the total load energy [kWh] per interval values calculated from
|
np.ndarray: Total load energy [kWh] per interval; NaN where any load meter
|
||||||
the load meter readings.
|
lacks full coverage or no load meter is configured.
|
||||||
|
|
||||||
|
Raises:
|
||||||
|
ValueError: If the period cannot be determined or is invalid.
|
||||||
"""
|
"""
|
||||||
if interval is None:
|
if interval is None:
|
||||||
interval = to_duration("1 hour")
|
interval = to_duration("1 hour")
|
||||||
|
if len(self) < 1 and (start_datetime is None or end_datetime is None):
|
||||||
if len(self) < 1:
|
# No data and no period: nothing to report.
|
||||||
# No data available
|
return np.zeros(0)
|
||||||
if start_datetime is None or end_datetime is None:
|
|
||||||
size = 0
|
|
||||||
else:
|
|
||||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
|
||||||
return np.zeros(size)
|
|
||||||
|
|
||||||
if start_datetime is None:
|
if start_datetime is None:
|
||||||
start_datetime = await self.min_datetime()
|
start_datetime = await self.min_datetime()
|
||||||
if end_datetime is None:
|
if end_datetime is None:
|
||||||
@@ -529,23 +799,26 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
|
|||||||
if start_datetime is None or end_datetime is None:
|
if start_datetime is None or end_datetime is None:
|
||||||
raise ValueError("Start and end datetimes are required for energy calculation")
|
raise ValueError("Start and end datetimes are required for energy calculation")
|
||||||
size = self._interval_count(start_datetime, end_datetime, interval)
|
size = self._interval_count(start_datetime, end_datetime, interval)
|
||||||
|
if size == 0:
|
||||||
|
return np.zeros(0)
|
||||||
|
load_keys = self.config.measurement.load_emr_keys or []
|
||||||
|
if not load_keys:
|
||||||
|
return np.full(size, np.nan)
|
||||||
|
|
||||||
load_total_kwh_array = np.zeros(size)
|
load_total_kwh_array = np.zeros(size)
|
||||||
|
meters_kwh = await self.meter_energy_kwh(load_keys, start_datetime, end_datetime, interval)
|
||||||
# Loop through all loads
|
for key, meter_kwh in meters_kwh.items():
|
||||||
if isinstance(self.config.measurement.load_emr_keys, list):
|
if np.isnan(meter_kwh).all():
|
||||||
for key in self.config.measurement.load_emr_keys:
|
message = (
|
||||||
# Calculate load per interval
|
f"Load meter '{key}' gives no usable energy for {start_datetime} .. "
|
||||||
load_array = await self._energy_from_meter_readings(
|
f"{end_datetime} (no readings, resets or gaps longer than its "
|
||||||
key=key,
|
"max_gap_seconds): the total load of this period is unknown."
|
||||||
start_datetime=start_datetime,
|
|
||||||
end_datetime=end_datetime,
|
|
||||||
interval=interval,
|
|
||||||
)
|
)
|
||||||
# Add calculated load to total load
|
self._warn_once(f"meter-unusable:{key}", message)
|
||||||
load_total_kwh_array += load_array
|
else:
|
||||||
debug_msg = f"Total load '{key}' calculation: {load_total_kwh_array}"
|
self._clear_warning(f"meter-unusable:{key}")
|
||||||
logger.debug(debug_msg)
|
load_total_kwh_array += meter_kwh
|
||||||
|
logger.debug(f"Total load calculation: {load_total_kwh_array}")
|
||||||
return load_total_kwh_array
|
return load_total_kwh_array
|
||||||
|
|
||||||
# ----------------------- Measurement Database Protocol ---------------------
|
# ----------------------- Measurement Database Protocol ---------------------
|
||||||
|
|||||||
@@ -4,11 +4,19 @@ from typing import Optional
|
|||||||
|
|
||||||
import numpy as np
|
import numpy as np
|
||||||
from loguru import logger
|
from loguru import logger
|
||||||
from pydantic import Field
|
from pydantic import Field, PrivateAttr
|
||||||
|
|
||||||
from akkudoktoreos.config.configabc import SettingsBaseModel
|
from akkudoktoreos.config.configabc import SettingsBaseModel
|
||||||
from akkudoktoreos.prediction.loadabc import LoadDataRecord, LoadProvider
|
from akkudoktoreos.prediction.loadabc import LoadDataRecord, LoadProvider
|
||||||
from akkudoktoreos.utils.datetimeutil import compare_datetimes, to_datetime, to_duration
|
from akkudoktoreos.utils.datetimeutil import (
|
||||||
|
DateTime,
|
||||||
|
compare_datetimes,
|
||||||
|
to_datetime,
|
||||||
|
to_duration,
|
||||||
|
)
|
||||||
|
|
||||||
|
# The load adjustment ignores meters whose common period ended longer ago than this.
|
||||||
|
LOAD_ADJUSTMENT_STALE_DAYS = 7
|
||||||
|
|
||||||
|
|
||||||
class LoadAkkudoktorCommonSettings(SettingsBaseModel):
|
class LoadAkkudoktorCommonSettings(SettingsBaseModel):
|
||||||
@@ -93,6 +101,9 @@ class LoadAkkudoktor(LoadProvider[LoadAkkudoktorDataRecord]):
|
|||||||
class LoadAkkudoktorAdjusted(LoadAkkudoktor):
|
class LoadAkkudoktorAdjusted(LoadAkkudoktor):
|
||||||
"""Fetch Load forecast data from Akkudoktor load profiles with adjustment by measurements."""
|
"""Fetch Load forecast data from Akkudoktor load profiles with adjustment by measurements."""
|
||||||
|
|
||||||
|
# End of the load meter period last warned about as stale (warned once).
|
||||||
|
_stale_adjustment_reported_end: Optional[DateTime] = PrivateAttr(default=None)
|
||||||
|
|
||||||
@classmethod
|
@classmethod
|
||||||
def provider_id(cls) -> str:
|
def provider_id(cls) -> str:
|
||||||
"""Return the unique identifier for the LoadAkkudoktor provider."""
|
"""Return the unique identifier for the LoadAkkudoktor provider."""
|
||||||
@@ -112,16 +123,42 @@ class LoadAkkudoktorAdjusted(LoadAkkudoktor):
|
|||||||
weekend_adjust = np.zeros(24)
|
weekend_adjust = np.zeros(24)
|
||||||
weekend_adjust_weight = np.zeros(24)
|
weekend_adjust_weight = np.zeros(24)
|
||||||
|
|
||||||
max_dt = await self.measurement.max_datetime()
|
if not self.config.measurement.load_emr_keys:
|
||||||
if max_dt is None:
|
logger.info(
|
||||||
# No measurements - return 0 adjustment
|
"LoadAkkudoktorAdjusted: measurement.load_emr_keys is not configured - "
|
||||||
return (weekday_adjust, weekday_adjust)
|
"no load adjustment."
|
||||||
|
)
|
||||||
|
return (weekday_adjust, weekend_adjust)
|
||||||
|
|
||||||
min_dt = await self.measurement.min_datetime()
|
# Compare against the period every load meter reports, not the whole store:
|
||||||
|
# other channels (PV, SoC) often reach further than the load meters.
|
||||||
|
period = await self.measurement.keys_common_period(
|
||||||
|
self.config.measurement.load_emr_keys, "LoadAkkudoktorAdjusted"
|
||||||
|
)
|
||||||
|
if period is None:
|
||||||
|
return (weekday_adjust, weekend_adjust)
|
||||||
|
min_dt, max_dt = period.first, period.last
|
||||||
|
if compare_datetimes(
|
||||||
|
max_dt.add(days=LOAD_ADJUSTMENT_STALE_DAYS), self.ems_start_datetime
|
||||||
|
).lt:
|
||||||
|
# A week that old says nothing about the current load profile.
|
||||||
|
message = (
|
||||||
|
f"LoadAkkudoktorAdjusted: load meter '{period.last_key}' last reported at "
|
||||||
|
f"{max_dt}, more than {LOAD_ADJUSTMENT_STALE_DAYS} days ago - no load "
|
||||||
|
"adjustment."
|
||||||
|
)
|
||||||
|
if (
|
||||||
|
self._stale_adjustment_reported_end is not None
|
||||||
|
and compare_datetimes(self._stale_adjustment_reported_end, max_dt).equal
|
||||||
|
):
|
||||||
|
logger.debug(message)
|
||||||
|
else:
|
||||||
|
self._stale_adjustment_reported_end = max_dt
|
||||||
|
logger.warning(message)
|
||||||
|
return (weekday_adjust, weekend_adjust)
|
||||||
|
|
||||||
# compare predictions with real measurement - try to use last 7 days
|
# compare predictions with real measurement - try to use last 7 days
|
||||||
# Keep the hourly buckets on full hours: the newest record may be an off-hour
|
# Keep the hourly buckets on full hours (#1447).
|
||||||
# device state (e.g. SoC stamped with the run time, #1447).
|
|
||||||
compare_end = max_dt.start_of("hour")
|
compare_end = max_dt.start_of("hour")
|
||||||
compare_start = compare_end - to_duration("7 days")
|
compare_start = compare_end - to_duration("7 days")
|
||||||
if compare_datetimes(compare_start, min_dt).lt:
|
if compare_datetimes(compare_start, min_dt).lt:
|
||||||
@@ -134,13 +171,31 @@ class LoadAkkudoktorAdjusted(LoadAkkudoktor):
|
|||||||
return (weekday_adjust, weekend_adjust)
|
return (weekday_adjust, weekend_adjust)
|
||||||
compare_interval = to_duration("1 hour")
|
compare_interval = to_duration("1 hour")
|
||||||
|
|
||||||
load_total_kwh_array = await self.measurement.load_total_kwh(
|
try:
|
||||||
start_datetime=compare_start,
|
load_total_kwh_array = await self.measurement.load_total_kwh(
|
||||||
end_datetime=compare_end,
|
start_datetime=compare_start,
|
||||||
interval=compare_interval,
|
end_datetime=compare_end,
|
||||||
)
|
interval=compare_interval,
|
||||||
|
)
|
||||||
|
except ValueError as exc:
|
||||||
|
self.measurement.report_conversion_failure(
|
||||||
|
"LoadAkkudoktorAdjusted",
|
||||||
|
f"Load adjustment: load meter energy conversion failed - no adjustment: {exc}",
|
||||||
|
)
|
||||||
|
return (weekday_adjust, weekend_adjust)
|
||||||
|
self.measurement.clear_conversion_failure("LoadAkkudoktorAdjusted")
|
||||||
|
missing_hours = int(np.isnan(load_total_kwh_array).sum())
|
||||||
|
if missing_hours:
|
||||||
|
logger.debug(
|
||||||
|
f"Load adjustment: {missing_hours} of {len(load_total_kwh_array)} hours lack "
|
||||||
|
"full load meter coverage and are skipped."
|
||||||
|
)
|
||||||
compare_dt = compare_start
|
compare_dt = compare_start
|
||||||
for i in range(len(load_total_kwh_array)):
|
for i in range(len(load_total_kwh_array)):
|
||||||
|
if np.isnan(load_total_kwh_array[i]):
|
||||||
|
# Unknown load (meter gap): no information about this hour.
|
||||||
|
compare_dt += compare_interval
|
||||||
|
continue
|
||||||
load_total_wh = load_total_kwh_array[i] * 1000
|
load_total_wh = load_total_kwh_array[i] * 1000
|
||||||
hour = compare_dt.hour
|
hour = compare_dt.hour
|
||||||
|
|
||||||
|
|||||||
@@ -41,10 +41,11 @@ import pandas as pd
|
|||||||
import pendulum
|
import pendulum
|
||||||
import requests
|
import requests
|
||||||
from loguru import logger
|
from loguru import logger
|
||||||
from pydantic import Field, field_validator, model_validator
|
from pydantic import Field, PrivateAttr, field_validator, model_validator
|
||||||
|
|
||||||
from akkudoktoreos.config.configabc import SettingsBaseModel
|
from akkudoktoreos.config.configabc import SettingsBaseModel
|
||||||
from akkudoktoreos.core.cache import cache_in_file
|
from akkudoktoreos.core.cache import cache_in_file
|
||||||
|
from akkudoktoreos.measurement.measurement import MeterPeriod
|
||||||
from akkudoktoreos.prediction.pvforecastabc import (
|
from akkudoktoreos.prediction.pvforecastabc import (
|
||||||
PVForecastDataRecordT,
|
PVForecastDataRecordT,
|
||||||
PVForecastProvider,
|
PVForecastProvider,
|
||||||
@@ -77,15 +78,15 @@ OPENMETEO_SNOW_VARIABLES = ("snowfall", "snow_depth")
|
|||||||
# Snow feedback warns when the newest PV meter reading is older than this.
|
# Snow feedback warns when the newest PV meter reading is older than this.
|
||||||
SNOW_FEEDBACK_STALE_HOURS = 3
|
SNOW_FEEDBACK_STALE_HOURS = 3
|
||||||
|
|
||||||
|
# Calibration warns when the common PV meter period ended longer ago than this.
|
||||||
|
CALIBRATION_STALE_HOURS = 24
|
||||||
|
|
||||||
# Open-Meteo hard limits for a single forecast request.
|
# Open-Meteo hard limits for a single forecast request.
|
||||||
MAX_FORECAST_DAYS = 16
|
MAX_FORECAST_DAYS = 16
|
||||||
MAX_PAST_DAYS = 92
|
MAX_PAST_DAYS = 92
|
||||||
|
|
||||||
TRANSPOSITION_MODELS = ("isotropic", "klucher", "haydavies", "reindl", "king", "perez")
|
TRANSPOSITION_MODELS = ("isotropic", "klucher", "haydavies", "reindl", "king", "perez")
|
||||||
|
|
||||||
# The measurement store converts energy for at most 31 days per query.
|
|
||||||
ENERGY_QUERY_MAX_DAYS = 30
|
|
||||||
|
|
||||||
# pvlib SAPM cell temperature parameter set per EOS `mountingplace`.
|
# pvlib SAPM cell temperature parameter set per EOS `mountingplace`.
|
||||||
MOUNTING_TEMPERATURE_MODEL = {
|
MOUNTING_TEMPERATURE_MODEL = {
|
||||||
"free": "open_rack_glass_glass",
|
"free": "open_rack_glass_glass",
|
||||||
@@ -93,19 +94,6 @@ MOUNTING_TEMPERATURE_MODEL = {
|
|||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@dataclass(frozen=True)
|
|
||||||
class PVMeterWindow:
|
|
||||||
"""Period every configured PV production meter reports.
|
|
||||||
|
|
||||||
Attributes:
|
|
||||||
first: Latest first reading across the PV meters.
|
|
||||||
last: Earliest last reading across the PV meters.
|
|
||||||
"""
|
|
||||||
|
|
||||||
first: DateTime
|
|
||||||
last: DateTime
|
|
||||||
|
|
||||||
|
|
||||||
def _utc_timestamp(moment: DateTime | pd.Timestamp) -> pd.Timestamp:
|
def _utc_timestamp(moment: DateTime | pd.Timestamp) -> pd.Timestamp:
|
||||||
"""Convert a moment to a UTC pandas timestamp.
|
"""Convert a moment to a UTC pandas timestamp.
|
||||||
|
|
||||||
@@ -589,6 +577,11 @@ class PVForecastAkkudoktorLocalCommonSettings(SettingsBaseModel):
|
|||||||
class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
||||||
"""Compute the PV forecast locally from Open-Meteo irradiance using pvlib."""
|
"""Compute the PV forecast locally from Open-Meteo irradiance using pvlib."""
|
||||||
|
|
||||||
|
# End of the common PV meter period last warned about as stale (warned once).
|
||||||
|
_stale_calibration_reported_end: Optional[DateTime] = PrivateAttr(default=None)
|
||||||
|
# Last PV reading the snow feedback last warned about as stale (warned once).
|
||||||
|
_stale_snow_reported_end: Optional[DateTime] = PrivateAttr(default=None)
|
||||||
|
|
||||||
@classmethod
|
@classmethod
|
||||||
def provider_id(cls) -> str:
|
def provider_id(cls) -> str:
|
||||||
"""Return the unique identifier for the PV-Forecast-Provider."""
|
"""Return the unique identifier for the PV-Forecast-Provider."""
|
||||||
@@ -1055,7 +1048,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
|
|
||||||
raw_ac = frame["ac_power"].to_numpy(dtype=float).copy()
|
raw_ac = frame["ac_power"].to_numpy(dtype=float).copy()
|
||||||
# Calibration and snow feedback share one scan of the PV meter readings.
|
# Calibration and snow feedback share one scan of the PV meter readings.
|
||||||
pv_window: Optional[PVMeterWindow] = None
|
pv_window: Optional[MeterPeriod] = None
|
||||||
if (
|
if (
|
||||||
calibrate
|
calibrate
|
||||||
and self.config.measurement.pv_production_emr_keys
|
and self.config.measurement.pv_production_emr_keys
|
||||||
@@ -1133,7 +1126,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
row_start = row_start - pd.Timedelta(minutes=self._settings.resolution_minutes)
|
row_start = row_start - pd.Timedelta(minutes=self._settings.resolution_minutes)
|
||||||
return row_start
|
return row_start
|
||||||
|
|
||||||
async def _pv_measurement_window(self) -> Optional[PVMeterWindow]:
|
async def _pv_measurement_window(self) -> Optional[MeterPeriod]:
|
||||||
"""Period that every configured PV production meter covers with readings.
|
"""Period that every configured PV production meter covers with readings.
|
||||||
|
|
||||||
The measurement store holds every meter, not just the PV ones. Load meters
|
The measurement store holds every meter, not just the PV ones. Load meters
|
||||||
@@ -1147,48 +1140,25 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
The common period, or None when a PV meter has no readings or the meters
|
The common period, or None when a PV meter has no readings or the meters
|
||||||
share no period.
|
share no period.
|
||||||
"""
|
"""
|
||||||
measurement = self.measurement
|
return await self.measurement.keys_common_period(
|
||||||
first = await measurement.min_datetime()
|
self.config.measurement.pv_production_emr_keys or [], "PVForecastAkkudoktorLocal"
|
||||||
last = await measurement.max_datetime()
|
)
|
||||||
if first is None or last is None:
|
|
||||||
return None
|
|
||||||
common_first: Optional[DateTime] = None
|
|
||||||
common_last: Optional[DateTime] = None
|
|
||||||
for key in self.config.measurement.pv_production_emr_keys or []:
|
|
||||||
dates, _ = await measurement.key_to_lists(
|
|
||||||
key=key,
|
|
||||||
start_datetime=first,
|
|
||||||
end_datetime=last.add(minutes=1),
|
|
||||||
)
|
|
||||||
if not dates:
|
|
||||||
return None
|
|
||||||
if common_first is None or compare_datetimes(dates[0], common_first).gt:
|
|
||||||
common_first = dates[0]
|
|
||||||
if common_last is None or compare_datetimes(dates[-1], common_last).lt:
|
|
||||||
common_last = dates[-1]
|
|
||||||
if common_first is None or common_last is None:
|
|
||||||
return None
|
|
||||||
if not compare_datetimes(common_first, common_last).lt:
|
|
||||||
logger.info(
|
|
||||||
"PVForecastAkkudoktorLocal: the PV production meters share no measurement "
|
|
||||||
f"period ({common_first} .. {common_last})."
|
|
||||||
)
|
|
||||||
return None
|
|
||||||
return PVMeterWindow(first=common_first, last=common_last)
|
|
||||||
|
|
||||||
async def _calibration_interval_minutes(self, start: Any, end: Any) -> int:
|
async def _calibration_interval_minutes(self, start: DateTime, end: DateTime) -> int:
|
||||||
"""Use native forecast slots only when every PV meter resolves them.
|
"""Use native forecast slots only when every PV meter resolves them.
|
||||||
|
|
||||||
Interpolating an hourly cumulative meter onto quarter hours would create a
|
Interpolating an hourly cumulative meter onto quarter hours would create a
|
||||||
perfectly flat, but invented, intrahour profile. Fall back to hourly fitting
|
perfectly flat, but invented, intrahour profile. Fall back to hourly fitting
|
||||||
until all configured production meters actually provide native slot readings.
|
until all configured production meters actually provide native slot readings.
|
||||||
|
Only valid readings count: a meter that marks its intrahour readings invalid
|
||||||
|
or unavailable resolves full hours only.
|
||||||
"""
|
"""
|
||||||
native_minutes = self._settings.resolution_minutes
|
native_minutes = self._settings.resolution_minutes
|
||||||
meter_resolutions: list[float] = []
|
meter_resolutions: list[float] = []
|
||||||
for key in self.config.measurement.pv_production_emr_keys or []:
|
keys = self.config.measurement.pv_production_emr_keys or []
|
||||||
dates, _ = await self.measurement.key_to_lists(
|
valid_datetimes = await self.measurement.keys_valid_datetimes(keys, start, end)
|
||||||
key=key, start_datetime=start, end_datetime=end
|
for key in keys:
|
||||||
)
|
dates = valid_datetimes[key]
|
||||||
if len(dates) < 3:
|
if len(dates) < 3:
|
||||||
return 60
|
return 60
|
||||||
deltas = np.asarray(
|
deltas = np.asarray(
|
||||||
@@ -1290,29 +1260,13 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
keys = self.config.measurement.pv_production_emr_keys or []
|
keys = self.config.measurement.pv_production_emr_keys or []
|
||||||
if not keys:
|
if not keys:
|
||||||
return np.asarray([], dtype=float)
|
return np.asarray([], dtype=float)
|
||||||
interval_seconds = int(interval.total_seconds())
|
meters_kwh = await self.measurement.meter_energy_kwh(
|
||||||
totals: Optional[np.ndarray] = None
|
keys, start_datetime, end_datetime, interval
|
||||||
for key in keys:
|
)
|
||||||
values: list[float] = []
|
return np.asarray(sum(meters_kwh.values()), dtype=float)
|
||||||
chunk_start = start_datetime
|
|
||||||
while compare_datetimes(chunk_start, end_datetime).lt:
|
|
||||||
chunk_end = chunk_start.add(days=ENERGY_QUERY_MAX_DAYS)
|
|
||||||
if compare_datetimes(chunk_end, end_datetime).gt:
|
|
||||||
chunk_end = end_datetime
|
|
||||||
intervals = await self.measurement.energy_intervals(
|
|
||||||
key, chunk_start, chunk_end, interval_seconds
|
|
||||||
)
|
|
||||||
values.extend(
|
|
||||||
np.nan if slot.energy_wh is None else slot.energy_wh / 1000.0
|
|
||||||
for slot in intervals
|
|
||||||
)
|
|
||||||
chunk_start = chunk_end
|
|
||||||
meter_kwh = np.asarray(values, dtype=float)
|
|
||||||
totals = meter_kwh if totals is None else totals + meter_kwh
|
|
||||||
return np.asarray(totals, dtype=float)
|
|
||||||
|
|
||||||
async def _fit_calibration(
|
async def _fit_calibration(
|
||||||
self, frame: pd.DataFrame, pv_window: Optional[PVMeterWindow]
|
self, frame: pd.DataFrame, pv_window: Optional[MeterPeriod]
|
||||||
) -> Optional[tuple[float, np.ndarray]]:
|
) -> Optional[tuple[float, np.ndarray]]:
|
||||||
"""Fit correction factors from measured PV production against the model.
|
"""Fit correction factors from measured PV production against the model.
|
||||||
|
|
||||||
@@ -1344,6 +1298,22 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
logger.info("PVForecastAkkudoktorLocal calibration: no PV measurements yet - skipping.")
|
logger.info("PVForecastAkkudoktorLocal calibration: no PV measurements yet - skipping.")
|
||||||
return None
|
return None
|
||||||
pv_min_datetime, reference_end = pv_window.first, pv_window.last
|
pv_min_datetime, reference_end = pv_window.first, pv_window.last
|
||||||
|
if compare_datetimes(
|
||||||
|
reference_end.add(hours=CALIBRATION_STALE_HOURS), self.ems_start_datetime
|
||||||
|
).lt:
|
||||||
|
message = (
|
||||||
|
f"PVForecastAkkudoktorLocal calibration: PV production meter "
|
||||||
|
f"'{pv_window.last_key}' last reported at {reference_end}, more than "
|
||||||
|
f"{CALIBRATION_STALE_HOURS} h ago - calibration can only use data up to then."
|
||||||
|
)
|
||||||
|
if (
|
||||||
|
self._stale_calibration_reported_end is not None
|
||||||
|
and compare_datetimes(self._stale_calibration_reported_end, reference_end).equal
|
||||||
|
):
|
||||||
|
logger.debug(message)
|
||||||
|
else:
|
||||||
|
self._stale_calibration_reported_end = reference_end
|
||||||
|
logger.warning(message)
|
||||||
|
|
||||||
lookback_days = settings.calibration_days
|
lookback_days = settings.calibration_days
|
||||||
if settings.calibration_outage_filter_enabled:
|
if settings.calibration_outage_filter_enabled:
|
||||||
@@ -1374,12 +1344,18 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
return None
|
return None
|
||||||
start, end = window.start_datetime, window.end_datetime
|
start, end = window.start_datetime, window.end_datetime
|
||||||
|
|
||||||
measured_kwh = np.asarray(
|
try:
|
||||||
await self._pv_production_total_kwh(
|
measured_kwh = await self._pv_production_total_kwh(
|
||||||
start_datetime=start, end_datetime=end, interval=interval
|
start_datetime=start, end_datetime=end, interval=interval
|
||||||
),
|
)
|
||||||
dtype=float,
|
except ValueError as exc:
|
||||||
)
|
self.measurement.report_conversion_failure(
|
||||||
|
"PVForecastAkkudoktorLocal calibration",
|
||||||
|
"PVForecastAkkudoktorLocal calibration: PV meter energy conversion failed - "
|
||||||
|
f"using the uncalibrated model: {exc}",
|
||||||
|
)
|
||||||
|
return None
|
||||||
|
self.measurement.clear_conversion_failure("PVForecastAkkudoktorLocal calibration")
|
||||||
if measured_kwh.size == 0 or not np.isfinite(measured_kwh).any():
|
if measured_kwh.size == 0 or not np.isfinite(measured_kwh).any():
|
||||||
logger.info(
|
logger.info(
|
||||||
"PVForecastAkkudoktorLocal calibration: no usable PV measurements - skipping."
|
"PVForecastAkkudoktorLocal calibration: no usable PV measurements - skipping."
|
||||||
@@ -1799,7 +1775,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
return coverage, corrections
|
return coverage, corrections
|
||||||
|
|
||||||
async def _snow_observations(
|
async def _snow_observations(
|
||||||
self, frame: pd.DataFrame, pv_window: Optional[PVMeterWindow]
|
self, frame: pd.DataFrame, pv_window: Optional[MeterPeriod]
|
||||||
) -> tuple[list[tuple[int, int, float]], Optional[float]]:
|
) -> tuple[list[tuple[int, int, float]], Optional[float]]:
|
||||||
"""Measured PV energy per meter interval, mapped onto forecast rows.
|
"""Measured PV energy per meter interval, mapped onto forecast rows.
|
||||||
|
|
||||||
@@ -1815,8 +1791,9 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
if not settings.snow_feedback_enabled or not self.config.measurement.pv_production_emr_keys:
|
if not settings.snow_feedback_enabled or not self.config.measurement.pv_production_emr_keys:
|
||||||
return [], None
|
return [], None
|
||||||
if pv_window is None:
|
if pv_window is None:
|
||||||
logger.warning(
|
# keys_common_period already logged why, once per condition.
|
||||||
"PVForecastAkkudoktorLocal snow feedback: no PV production readings - "
|
logger.debug(
|
||||||
|
"PVForecastAkkudoktorLocal snow feedback: no PV meter period - "
|
||||||
"using the weather-only snow model."
|
"using the weather-only snow model."
|
||||||
)
|
)
|
||||||
return [], None
|
return [], None
|
||||||
@@ -1824,11 +1801,19 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
if compare_datetimes(
|
if compare_datetimes(
|
||||||
pv_last.add(hours=SNOW_FEEDBACK_STALE_HOURS), self.ems_start_datetime
|
pv_last.add(hours=SNOW_FEEDBACK_STALE_HOURS), self.ems_start_datetime
|
||||||
).lt:
|
).lt:
|
||||||
logger.warning(
|
message = (
|
||||||
f"PVForecastAkkudoktorLocal snow feedback: last PV production reading "
|
f"PVForecastAkkudoktorLocal snow feedback: last PV production reading "
|
||||||
f"{pv_last} is older than {SNOW_FEEDBACK_STALE_HOURS} h - the snow "
|
f"{pv_last} is older than {SNOW_FEEDBACK_STALE_HOURS} h - the snow "
|
||||||
"coverage relies on the weather model since then."
|
"coverage relies on the weather model since then."
|
||||||
)
|
)
|
||||||
|
if (
|
||||||
|
self._stale_snow_reported_end is not None
|
||||||
|
and compare_datetimes(self._stale_snow_reported_end, pv_last).equal
|
||||||
|
):
|
||||||
|
logger.debug(message)
|
||||||
|
else:
|
||||||
|
self._stale_snow_reported_end = pv_last
|
||||||
|
logger.warning(message)
|
||||||
|
|
||||||
resolution = pd.Timedelta(minutes=settings.resolution_minutes)
|
resolution = pd.Timedelta(minutes=settings.resolution_minutes)
|
||||||
row_start = self._row_start_index(frame)
|
row_start = self._row_start_index(frame)
|
||||||
@@ -1845,14 +1830,20 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
return [], None
|
return [], None
|
||||||
start = window.start
|
start = window.start
|
||||||
|
|
||||||
measured = np.asarray(
|
try:
|
||||||
await self._pv_production_total_kwh(
|
measured = await self._pv_production_total_kwh(
|
||||||
start_datetime=window.start_datetime,
|
start_datetime=window.start_datetime,
|
||||||
end_datetime=window.end_datetime,
|
end_datetime=window.end_datetime,
|
||||||
interval=to_duration(f"{interval_minutes} minutes"),
|
interval=to_duration(f"{interval_minutes} minutes"),
|
||||||
),
|
)
|
||||||
dtype=float,
|
except ValueError as exc:
|
||||||
)
|
self.measurement.report_conversion_failure(
|
||||||
|
"PVForecastAkkudoktorLocal snow feedback",
|
||||||
|
"PVForecastAkkudoktorLocal snow feedback: PV meter energy conversion failed - "
|
||||||
|
f"using the weather-only snow model: {exc}",
|
||||||
|
)
|
||||||
|
return [], None
|
||||||
|
self.measurement.clear_conversion_failure("PVForecastAkkudoktorLocal snow feedback")
|
||||||
interval_hours = interval_minutes / 60.0
|
interval_hours = interval_minutes / 60.0
|
||||||
# A meter jump (reset, a sub-meter dropping out of a sum) shows up as an
|
# A meter jump (reset, a sub-meter dropping out of a sum) shows up as an
|
||||||
# impossible yield. Drop it rather than learn snow - or its absence - from it.
|
# impossible yield. Drop it rather than learn snow - or its absence - from it.
|
||||||
@@ -1879,7 +1870,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
|
|||||||
plane_ac: np.ndarray,
|
plane_ac: np.ndarray,
|
||||||
plane_poa: np.ndarray,
|
plane_poa: np.ndarray,
|
||||||
plane_tilt: np.ndarray,
|
plane_tilt: np.ndarray,
|
||||||
pv_window: Optional[PVMeterWindow],
|
pv_window: Optional[MeterPeriod],
|
||||||
) -> pd.DataFrame:
|
) -> pd.DataFrame:
|
||||||
"""Reduce the forecast by the (measurement-corrected) snow coverage."""
|
"""Reduce the forecast by the (measurement-corrected) snow coverage."""
|
||||||
settings = self._settings
|
settings = self._settings
|
||||||
|
|||||||
@@ -49,7 +49,12 @@ def loadakkudoktoradjusted(config_eos):
|
|||||||
config_eos.merge_settings_from_dict(settings)
|
config_eos.merge_settings_from_dict(settings)
|
||||||
assert config_eos.load.provider == "LoadAkkudoktorAdjusted"
|
assert config_eos.load.provider == "LoadAkkudoktorAdjusted"
|
||||||
assert config_eos.load.loadakkudoktor.loadakkudoktor_year_energy_kwh == 1000
|
assert config_eos.load.loadakkudoktor.loadakkudoktor_year_energy_kwh == 1000
|
||||||
return LoadAkkudoktorAdjusted()
|
# The adjustment ignores stale meter periods; run the tests next to their data.
|
||||||
|
ems_class = type(get_ems())
|
||||||
|
previous_start = ems_class._start_datetime
|
||||||
|
get_ems().set_start_datetime(to_datetime("2024-01-02T00:00:00"))
|
||||||
|
yield LoadAkkudoktorAdjusted()
|
||||||
|
ems_class._start_datetime = previous_start
|
||||||
|
|
||||||
@pytest_asyncio.fixture
|
@pytest_asyncio.fixture
|
||||||
async def measurement_eos():
|
async def measurement_eos():
|
||||||
@@ -264,6 +269,8 @@ async def empty_measurement(config_eos):
|
|||||||
"""Own, empty measurement store (the singleton is shared between tests)."""
|
"""Own, empty measurement store (the singleton is shared between tests)."""
|
||||||
measurement = get_measurement()
|
measurement = get_measurement()
|
||||||
await measurement.delete_by_datetime(None, None)
|
await measurement.delete_by_datetime(None, None)
|
||||||
|
# Warn-once state lives on the shared singleton; start each test fresh.
|
||||||
|
measurement._reported_warnings.clear()
|
||||||
config_eos.merge_settings_from_dict(
|
config_eos.merge_settings_from_dict(
|
||||||
{"devices": {"max_batteries": 1, "batteries": {"storage": {"profile_adjustment": {"nominal_capacity_wh": 2000}}}}}
|
{"devices": {"max_batteries": 1, "batteries": {"storage": {"profile_adjustment": {"nominal_capacity_wh": 2000}}}}}
|
||||||
)
|
)
|
||||||
@@ -290,6 +297,7 @@ async def _adjustment_window(adjusted, measurement):
|
|||||||
@pytest.mark.asyncio
|
@pytest.mark.asyncio
|
||||||
async def test_adjustment_buckets_stay_on_full_hours(loadakkudoktoradjusted, empty_measurement):
|
async def test_adjustment_buckets_stay_on_full_hours(loadakkudoktoradjusted, empty_measurement):
|
||||||
"""A newer off-hour record (e.g. a device SoC) must not shift the hourly buckets (#1447)."""
|
"""A newer off-hour record (e.g. a device SoC) must not shift the hourly buckets (#1447)."""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
|
||||||
dt = to_datetime("2024-01-01T00:00:00")
|
dt = to_datetime("2024-01-01T00:00:00")
|
||||||
for hour in range(25):
|
for hour in range(25):
|
||||||
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
@@ -319,3 +327,175 @@ async def test_adjustment_within_first_hour_returns_zero(
|
|||||||
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
|
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
|
||||||
assert calls == []
|
assert calls == []
|
||||||
assert not weekday.any() and not weekend.any()
|
assert not weekday.any() and not weekend.any()
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_skips_hours_without_load_meter_coverage(
|
||||||
|
loadakkudoktoradjusted, empty_measurement
|
||||||
|
):
|
||||||
|
"""Hours the load meters do not cover are unknown and must not adjust the profile."""
|
||||||
|
# A Monday, in the zone whose local hours the adjustment buckets.
|
||||||
|
timezone = loadakkudoktoradjusted.config.general.timezone
|
||||||
|
dt = to_datetime("2024-01-01T00:00:00", in_timezone=timezone)
|
||||||
|
for hour in range(13):
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load1_mr", 500.0 + hour)
|
||||||
|
# Another channel keeps the store going until midnight.
|
||||||
|
await empty_measurement.update_value(dt.add(hours=24), "storage-soc-factor", 0.42)
|
||||||
|
|
||||||
|
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
|
||||||
|
|
||||||
|
assert calls
|
||||||
|
assert np.isfinite(weekday).all() and np.isfinite(weekend).all()
|
||||||
|
assert (weekday[:12] != 0.0).all()
|
||||||
|
assert (weekday[12:] == 0.0).all()
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_falls_back_when_the_meter_conversion_fails(
|
||||||
|
loadakkudoktoradjusted, empty_measurement, caplog
|
||||||
|
):
|
||||||
|
"""A broken meter history disables the adjustment instead of the load prediction.
|
||||||
|
|
||||||
|
The failure is an error once per streak, not on every prediction run.
|
||||||
|
"""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
|
||||||
|
dt = to_datetime("2024-01-01T00:00:00")
|
||||||
|
for hour in range(25):
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
|
|
||||||
|
def failure_levels() -> set[str]:
|
||||||
|
levels = {r.levelname for r in caplog.records if "conversion failed" in r.getMessage()}
|
||||||
|
caplog.clear()
|
||||||
|
return levels
|
||||||
|
|
||||||
|
with caplog.at_level("DEBUG"):
|
||||||
|
with patch.object(
|
||||||
|
type(empty_measurement),
|
||||||
|
"load_total_kwh",
|
||||||
|
side_effect=ValueError("Overlapping source energy intervals."),
|
||||||
|
):
|
||||||
|
weekday, weekend = await loadakkudoktoradjusted._calculate_adjustment(
|
||||||
|
np.random.rand(365, 2, 24)
|
||||||
|
)
|
||||||
|
assert failure_levels() == {"ERROR"}
|
||||||
|
await loadakkudoktoradjusted._calculate_adjustment(np.random.rand(365, 2, 24))
|
||||||
|
assert failure_levels() == {"DEBUG"}
|
||||||
|
# A successful conversion ends the streak.
|
||||||
|
await loadakkudoktoradjusted._calculate_adjustment(np.random.rand(365, 2, 24))
|
||||||
|
with patch.object(
|
||||||
|
type(empty_measurement),
|
||||||
|
"load_total_kwh",
|
||||||
|
side_effect=ValueError("Overlapping source energy intervals."),
|
||||||
|
):
|
||||||
|
await loadakkudoktoradjusted._calculate_adjustment(np.random.rand(365, 2, 24))
|
||||||
|
assert failure_levels() == {"ERROR"}
|
||||||
|
|
||||||
|
assert (weekday == 0.0).all() and (weekend == 0.0).all()
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_without_load_meters_is_zero(loadakkudoktoradjusted, empty_measurement):
|
||||||
|
"""Without configured load meters there is nothing to adjust from."""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = None
|
||||||
|
for day in (1, 2):
|
||||||
|
await empty_measurement.update_value(
|
||||||
|
to_datetime(f"2024-01-0{day}T00:00:00"), "storage-soc-factor", 0.5
|
||||||
|
)
|
||||||
|
|
||||||
|
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
|
||||||
|
|
||||||
|
assert calls == []
|
||||||
|
assert (weekday == 0.0).all() and (weekend == 0.0).all()
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_window_follows_the_load_meters(
|
||||||
|
loadakkudoktoradjusted, empty_measurement
|
||||||
|
):
|
||||||
|
"""A load meter lagging behind other channels still gives its last 7 days."""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
|
||||||
|
dt = to_datetime("2024-01-01T00:00:00")
|
||||||
|
for hour in range(10 * 24 + 1):
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
|
# SoC keeps reporting three days after the load meter stopped.
|
||||||
|
await empty_measurement.update_value(dt.add(days=13), "storage-soc-factor", 0.42)
|
||||||
|
|
||||||
|
_, calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
|
||||||
|
|
||||||
|
assert calls
|
||||||
|
assert compare_datetimes(calls[0]["end_datetime"], dt.add(days=10)).equal
|
||||||
|
assert compare_datetimes(calls[0]["start_datetime"], dt.add(days=3)).equal
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_ignores_a_stale_load_meter_period(
|
||||||
|
loadakkudoktoradjusted, empty_measurement, caplog
|
||||||
|
):
|
||||||
|
"""A load meter that stopped long ago must not adjust today's profile with old weeks."""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
|
||||||
|
dt = to_datetime("2024-01-01T00:00:00")
|
||||||
|
for hour in range(3 * 24 + 1):
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
|
get_ems().set_start_datetime(dt.add(days=30))
|
||||||
|
|
||||||
|
def stale_warnings() -> int:
|
||||||
|
return sum(
|
||||||
|
record.levelname == "WARNING"
|
||||||
|
and "load meter 'load0_mr' last reported at" in record.getMessage()
|
||||||
|
for record in caplog.records
|
||||||
|
)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
(weekday, weekend), calls = await _adjustment_window(
|
||||||
|
loadakkudoktoradjusted, empty_measurement
|
||||||
|
)
|
||||||
|
first_run = stale_warnings()
|
||||||
|
await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
|
||||||
|
|
||||||
|
assert calls == []
|
||||||
|
assert (weekday == 0.0).all() and (weekend == 0.0).all()
|
||||||
|
assert first_run > 0
|
||||||
|
assert stale_warnings() == first_run
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_names_a_load_meter_without_readings(
|
||||||
|
loadakkudoktoradjusted, empty_measurement, caplog
|
||||||
|
):
|
||||||
|
"""A configured load meter key without readings (e.g. a typo) is named in a warning."""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr", "load0_mr_typo"]
|
||||||
|
dt = to_datetime("2024-01-01T00:00:00")
|
||||||
|
for hour in range(25):
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
(weekday, weekend), calls = await _adjustment_window(
|
||||||
|
loadakkudoktoradjusted, empty_measurement
|
||||||
|
)
|
||||||
|
|
||||||
|
assert calls == []
|
||||||
|
assert (weekday == 0.0).all() and (weekend == 0.0).all()
|
||||||
|
assert "['load0_mr_typo'] have no valid readings" in caplog.text
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_adjustment_names_a_replaced_load_meter(
|
||||||
|
loadakkudoktoradjusted, empty_measurement, caplog
|
||||||
|
):
|
||||||
|
"""Meters that share no period (a replaced meter still configured) are named."""
|
||||||
|
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||||
|
dt = to_datetime("2024-01-01T00:00:00")
|
||||||
|
for hour in range(25):
|
||||||
|
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
|
||||||
|
await empty_measurement.update_value(dt.add(days=2, hours=hour), "load1_mr", 900.0 + hour)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
(weekday, weekend), calls = await _adjustment_window(
|
||||||
|
loadakkudoktoradjusted, empty_measurement
|
||||||
|
)
|
||||||
|
|
||||||
|
assert calls == []
|
||||||
|
assert (weekday == 0.0).all() and (weekend == 0.0).all()
|
||||||
|
assert "meter 'load0_mr' last reported at" in caplog.text
|
||||||
|
assert "the meters share no period" in caplog.text
|
||||||
|
|||||||
+273
-86
@@ -9,14 +9,17 @@ from pydantic import ValidationError
|
|||||||
|
|
||||||
from akkudoktoreos.core.coreabc import get_measurement
|
from akkudoktoreos.core.coreabc import get_measurement
|
||||||
from akkudoktoreos.core.dataabc import DataSequence
|
from akkudoktoreos.core.dataabc import DataSequence
|
||||||
|
from akkudoktoreos.core.databaseabc import DatabaseTimestamp
|
||||||
from akkudoktoreos.measurement.measurement import (
|
from akkudoktoreos.measurement.measurement import (
|
||||||
MeasurementChannelSettings,
|
MeasurementChannelSettings,
|
||||||
MeasurementCommonSettings,
|
MeasurementCommonSettings,
|
||||||
MeasurementDataRecord,
|
MeasurementDataRecord,
|
||||||
)
|
)
|
||||||
|
from akkudoktoreos.measurement.quality import SampleQuality
|
||||||
from akkudoktoreos.utils.datetimeutil import (
|
from akkudoktoreos.utils.datetimeutil import (
|
||||||
compare_datetimes,
|
compare_datetimes,
|
||||||
to_datetime,
|
to_datetime,
|
||||||
|
to_duration,
|
||||||
)
|
)
|
||||||
|
|
||||||
|
|
||||||
@@ -187,6 +190,8 @@ class TestMeasurement:
|
|||||||
config_eos.measurement.load_emr_keys = ["load0_mr", "load1_mr", "load2_mr", "load3_mr"]
|
config_eos.measurement.load_emr_keys = ["load0_mr", "load1_mr", "load2_mr", "load3_mr"]
|
||||||
measurement = get_measurement()
|
measurement = get_measurement()
|
||||||
await measurement.delete_by_datetime(None, None)
|
await measurement.delete_by_datetime(None, None)
|
||||||
|
# Warn-once state lives on the shared singleton; start each test fresh.
|
||||||
|
measurement._reported_warnings.clear()
|
||||||
record0 = MeasurementDataRecord(
|
record0 = MeasurementDataRecord(
|
||||||
date_time=datetime(2023, 1, 1, hour=0),
|
date_time=datetime(2023, 1, 1, hour=0),
|
||||||
load0_mr=100,
|
load0_mr=100,
|
||||||
@@ -255,109 +260,176 @@ class TestMeasurement:
|
|||||||
with pytest.raises(ValueError, match="interval must be positive"):
|
with pytest.raises(ValueError, match="interval must be positive"):
|
||||||
measurement_eos._interval_count(start, end, duration(hours=0))
|
measurement_eos._interval_count(start, end, duration(hours=0))
|
||||||
|
|
||||||
async def test_energy_from_meter_readings_valid_input(self, measurement_eos):
|
async def test_meter_energy_kwh_valid_input(self, measurement_eos):
|
||||||
"""Test _energy_from_meter_readings with valid inputs and proper alignment of load data."""
|
"""Energy per interval is the difference of the readings at its boundaries."""
|
||||||
key = "load0_mr"
|
result = await measurement_eos.meter_energy_kwh(
|
||||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
["load0_mr", "load1_mr"],
|
||||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
to_datetime("2023-01-01T00:00:00"),
|
||||||
interval = duration(hours=1)
|
to_datetime("2023-01-01T05:00:00"),
|
||||||
|
to_duration("1 hour"),
|
||||||
load_array = await measurement_eos._energy_from_meter_readings(
|
|
||||||
key, start_datetime, end_datetime, interval
|
|
||||||
)
|
)
|
||||||
|
|
||||||
expected_load_array = np.array([50, 50, 50, 50, 50]) # Differences between consecutive readings
|
np.testing.assert_array_equal(result["load0_mr"], [50, 50, 50, 50, 50])
|
||||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
np.testing.assert_array_equal(result["load1_mr"], [50, 50, 50, 50, 50])
|
||||||
|
|
||||||
async def test_energy_from_meter_readings_empty_array(self, measurement_eos):
|
async def test_meter_energy_kwh_interpolates_a_missing_reading(self, measurement_eos):
|
||||||
"""Test _energy_from_meter_readings with no data (empty array)."""
|
"""A reading missing at an interval boundary is interpolated from its neighbours."""
|
||||||
key = "load0_mr"
|
|
||||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
start_datetime = to_datetime("2023-01-01T00:00:00")
|
||||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
record = await measurement_eos.get_by_datetime(to_datetime("2023-01-01T05:00:00"))
|
||||||
interval = duration(hours=1)
|
|
||||||
|
|
||||||
# Use empyt records array
|
|
||||||
await measurement_eos.delete_by_datetime(start_datetime, end_datetime)
|
|
||||||
|
|
||||||
load_array = await measurement_eos._energy_from_meter_readings(
|
|
||||||
key, start_datetime, end_datetime, interval
|
|
||||||
)
|
|
||||||
|
|
||||||
# Expected: an array of zeros with one less than the number of intervals
|
|
||||||
expected_size = (
|
|
||||||
measurement_eos._interval_count(start_datetime, end_datetime + interval, interval) - 1
|
|
||||||
)
|
|
||||||
expected_load_array = np.zeros(expected_size)
|
|
||||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
|
||||||
|
|
||||||
async def test_energy_from_meter_readings_misaligned_array(self, measurement_eos):
|
|
||||||
"""Test _energy_from_meter_readings with misaligned array size."""
|
|
||||||
key = "load1_mr"
|
|
||||||
interval = duration(hours=1)
|
|
||||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
|
||||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
|
||||||
|
|
||||||
# Use misaligned array, latest interval set to 2 hours (instead of 1 hour)
|
|
||||||
latest_record_datetime = to_datetime("2023-01-01T05:00:00")
|
|
||||||
new_record_datetime = to_datetime("2023-01-01T06:00:00")
|
|
||||||
record = await measurement_eos.get_by_datetime(latest_record_datetime)
|
|
||||||
assert record is not None
|
assert record is not None
|
||||||
await measurement_eos.delete_by_datetime(start_datetime = latest_record_datetime,
|
await measurement_eos.delete_by_datetime(
|
||||||
end_datetime = new_record_datetime)
|
start_datetime=to_datetime("2023-01-01T05:00:00"),
|
||||||
record.date_time = new_record_datetime
|
end_datetime=to_datetime("2023-01-01T06:00:00"),
|
||||||
|
)
|
||||||
|
record.date_time = to_datetime("2023-01-01T06:00:00")
|
||||||
|
record.load1_mr = 500
|
||||||
await measurement_eos.insert_by_datetime(record)
|
await measurement_eos.insert_by_datetime(record)
|
||||||
|
|
||||||
# Check test setup
|
result = await measurement_eos.meter_energy_kwh(
|
||||||
dates, values = await measurement_eos.key_to_lists(key, start_datetime, None)
|
["load1_mr"], start_datetime, to_datetime("2023-01-01T06:00:00"), to_duration("1 hour")
|
||||||
assert dates == [
|
|
||||||
to_datetime("2023-01-01T00:00:00"),
|
|
||||||
to_datetime("2023-01-01T01:00:00"),
|
|
||||||
to_datetime("2023-01-01T02:00:00"),
|
|
||||||
to_datetime("2023-01-01T03:00:00"),
|
|
||||||
to_datetime("2023-01-01T04:00:00"),
|
|
||||||
to_datetime("2023-01-01T06:00:00"),
|
|
||||||
]
|
|
||||||
assert values == [200, 250, 300, 350, 400, 450]
|
|
||||||
array = await measurement_eos.key_to_array(key, start_datetime, end_datetime + interval, interval=interval)
|
|
||||||
np.testing.assert_array_equal(array, [200, 250, 300, 350, 400, 425])
|
|
||||||
|
|
||||||
load_array = await measurement_eos._energy_from_meter_readings(
|
|
||||||
key, start_datetime, end_datetime, interval
|
|
||||||
)
|
)
|
||||||
|
|
||||||
expected_load_array = np.array([50., 50., 50., 50., 25.]) # Differences between consecutive readings
|
np.testing.assert_array_equal(result["load1_mr"], [50.0, 50.0, 50.0, 50.0, 50.0, 50.0])
|
||||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
|
||||||
|
|
||||||
async def test_energy_from_meter_readings_partial_data(self, measurement_eos, caplog):
|
async def test_meter_energy_kwh_is_nan_outside_the_readings(self, measurement_eos):
|
||||||
"""Test _energy_from_meter_readings with partial data (misaligned but empty array)."""
|
"""Intervals before the first or after the last reading are unknown."""
|
||||||
key = "load2_mr"
|
result = await measurement_eos.meter_energy_kwh(
|
||||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
["load0_mr", "load2_mr"],
|
||||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
to_datetime("2022-12-31T23:00:00"),
|
||||||
interval = duration(hours=1)
|
to_datetime("2023-01-01T07:00:00"),
|
||||||
|
to_duration("1 hour"),
|
||||||
|
)
|
||||||
|
|
||||||
with caplog.at_level("DEBUG"):
|
np.testing.assert_array_equal(
|
||||||
load_array = await measurement_eos._energy_from_meter_readings(
|
result["load0_mr"], [np.nan, 50, 50, 50, 50, 50, np.nan, np.nan]
|
||||||
key, start_datetime, end_datetime, interval
|
)
|
||||||
|
assert np.isnan(result["load2_mr"]).all()
|
||||||
|
|
||||||
|
async def test_meter_energy_kwh_extends_a_partial_last_interval(self, measurement_eos):
|
||||||
|
"""A period that ends inside an interval still yields that full interval."""
|
||||||
|
result = await measurement_eos.meter_energy_kwh(
|
||||||
|
["load0_mr"],
|
||||||
|
to_datetime("2023-01-01T00:00:00"),
|
||||||
|
to_datetime("2023-01-01T02:20:00"),
|
||||||
|
to_duration("1 hour"),
|
||||||
|
)
|
||||||
|
|
||||||
|
np.testing.assert_array_equal(result["load0_mr"], [50, 50, 50])
|
||||||
|
|
||||||
|
async def test_meter_energy_kwh_negative_interval(self, measurement_eos):
|
||||||
|
"""A non-positive interval is rejected."""
|
||||||
|
with pytest.raises(ValueError, match="positive whole number of seconds"):
|
||||||
|
await measurement_eos.meter_energy_kwh(
|
||||||
|
["load0_mr"],
|
||||||
|
to_datetime("2023-01-01T00:00:00"),
|
||||||
|
to_datetime("2023-01-01T05:00:00"),
|
||||||
|
to_duration(-3600),
|
||||||
)
|
)
|
||||||
|
|
||||||
expected_size = (
|
async def test_keys_first_and_last_datetime(self, measurement_eos):
|
||||||
measurement_eos._interval_count(start_datetime, end_datetime + interval, interval) - 1
|
"""First and last valid reading per key, each key on its own.
|
||||||
|
|
||||||
|
load1_mr reports two days longer than load0_mr, so the backward scan finds the
|
||||||
|
two last readings in different windows; a trailing non-finite value of
|
||||||
|
load0_mr is no reading.
|
||||||
|
"""
|
||||||
|
for hour in range(6, 54):
|
||||||
|
await measurement_eos.update_value(
|
||||||
|
to_datetime("2023-01-01T00:00:00").add(hours=hour), "load1_mr", 450 + hour
|
||||||
|
)
|
||||||
|
await measurement_eos.update_value(
|
||||||
|
to_datetime("2023-01-03T12:00:00"), "load0_mr", float("nan")
|
||||||
)
|
)
|
||||||
expected_load_array = np.zeros(expected_size)
|
keys = ["load0_mr", "load1_mr", "load1_mr", "load2_mr"]
|
||||||
np.testing.assert_array_equal(load_array, expected_load_array)
|
|
||||||
|
|
||||||
async def test_energy_from_meter_readings_negative_interval(self, measurement_eos):
|
firsts = await measurement_eos.keys_first_datetime(keys)
|
||||||
"""Test _energy_from_meter_readings with a negative interval."""
|
lasts = await measurement_eos.keys_last_datetime(keys)
|
||||||
key = "load3_mr"
|
|
||||||
start_datetime = to_datetime("2023-01-01T00:00:00")
|
|
||||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
|
||||||
interval = duration(hours=-1)
|
|
||||||
|
|
||||||
with pytest.raises(ValueError, match="interval must be positive"):
|
assert firsts == {
|
||||||
await measurement_eos._energy_from_meter_readings(key, start_datetime, end_datetime, interval)
|
"load0_mr": to_datetime("2023-01-01T00:00:00"),
|
||||||
|
"load1_mr": to_datetime("2023-01-01T00:00:00"),
|
||||||
|
}
|
||||||
|
assert lasts == {
|
||||||
|
"load0_mr": to_datetime("2023-01-01T05:00:00"),
|
||||||
|
"load1_mr": to_datetime("2023-01-03T05:00:00"),
|
||||||
|
}
|
||||||
|
timezone = measurement_eos.config.general.timezone
|
||||||
|
assert all(stamp.timezone_name == timezone for stamp in [*firsts.values(), *lasts.values()])
|
||||||
|
|
||||||
|
async def test_conversion_failure_is_logged_once_per_streak(self, measurement_eos, caplog):
|
||||||
|
"""Error on the first failure, debug while it persists, error again after a success."""
|
||||||
|
|
||||||
|
def levels() -> set[str]:
|
||||||
|
levels = {r.levelname for r in caplog.records if "conversion failed" in r.getMessage()}
|
||||||
|
caplog.clear()
|
||||||
|
return levels
|
||||||
|
|
||||||
|
with caplog.at_level("DEBUG"):
|
||||||
|
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
|
||||||
|
assert levels() == {"ERROR"}
|
||||||
|
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
|
||||||
|
assert levels() == {"DEBUG"}
|
||||||
|
# Each consumer has its own streak.
|
||||||
|
measurement_eos.report_conversion_failure("other", "other: conversion failed")
|
||||||
|
assert levels() == {"ERROR"}
|
||||||
|
measurement_eos.clear_conversion_failure("consumer")
|
||||||
|
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
|
||||||
|
assert levels() == {"ERROR"}
|
||||||
|
|
||||||
|
async def test_keys_valid_datetimes(self, measurement_eos):
|
||||||
|
"""Stamps of valid readings in [start, end): invalid quality does not count."""
|
||||||
|
stamp = to_datetime("2023-01-01T02:00:00")
|
||||||
|
record = await measurement_eos.db_get_record(DatabaseTimestamp.from_datetime(stamp))
|
||||||
|
record.sample_quality["load0_mr"] = SampleQuality(status="invalid")
|
||||||
|
await measurement_eos.db_mark_dirty_record(record)
|
||||||
|
|
||||||
|
stamps = await measurement_eos.keys_valid_datetimes(
|
||||||
|
["load0_mr", "load_silent_mr"],
|
||||||
|
to_datetime("2023-01-01T01:00:00"),
|
||||||
|
to_datetime("2023-01-01T04:00:00"),
|
||||||
|
)
|
||||||
|
|
||||||
|
assert stamps == {
|
||||||
|
"load0_mr": [to_datetime("2023-01-01T01:00:00"), to_datetime("2023-01-01T03:00:00")],
|
||||||
|
"load_silent_mr": [],
|
||||||
|
}
|
||||||
|
|
||||||
|
async def test_load_total_kwh_warns_once_about_a_silent_meter(self, measurement_eos, caplog):
|
||||||
|
"""A configured meter that never reports is a warning once, not on every run."""
|
||||||
|
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load_silent_mr"]
|
||||||
|
period = {
|
||||||
|
"start_datetime": to_datetime("2023-01-01T00:00:00"),
|
||||||
|
"end_datetime": to_datetime("2023-01-01T03:00:00"),
|
||||||
|
"interval": to_duration("1 hour"),
|
||||||
|
}
|
||||||
|
|
||||||
|
def silent_meter_warnings() -> int:
|
||||||
|
return sum(
|
||||||
|
record.levelname == "WARNING"
|
||||||
|
and "'load_silent_mr' gives no usable energy" in record.getMessage()
|
||||||
|
for record in caplog.records
|
||||||
|
)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
await measurement_eos.load_total_kwh(**period)
|
||||||
|
first_run = silent_meter_warnings()
|
||||||
|
await measurement_eos.load_total_kwh(**period)
|
||||||
|
|
||||||
|
assert first_run > 0
|
||||||
|
assert silent_meter_warnings() == first_run
|
||||||
|
|
||||||
|
async def test_load_total_kwh_empty_store_without_period(self, measurement_eos):
|
||||||
|
"""No data and no period yields an empty result, not an error."""
|
||||||
|
await measurement_eos.delete_by_datetime(None, None)
|
||||||
|
|
||||||
|
result = await measurement_eos.load_total_kwh()
|
||||||
|
|
||||||
|
assert result.shape == (0,)
|
||||||
|
|
||||||
async def test_load_total_kwh(self, measurement_eos):
|
async def test_load_total_kwh(self, measurement_eos):
|
||||||
"""Test total load calculation."""
|
"""Test total load calculation."""
|
||||||
|
# Only these meters report; a silent configured meter makes the total unknown.
|
||||||
|
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||||
start_datetime = to_datetime("2023-01-01T03:00:00")
|
start_datetime = to_datetime("2023-01-01T03:00:00")
|
||||||
end_datetime = to_datetime("2023-01-01T05:00:00")
|
end_datetime = to_datetime("2023-01-01T05:00:00")
|
||||||
interval = duration(hours=1)
|
interval = duration(hours=1)
|
||||||
@@ -376,11 +448,13 @@ class TestMeasurement:
|
|||||||
interval = duration(hours=1)
|
interval = duration(hours=1)
|
||||||
|
|
||||||
result = await measurement_eos.load_total_kwh(start_datetime=start_datetime, end_datetime=end_datetime, interval=interval)
|
result = await measurement_eos.load_total_kwh(start_datetime=start_datetime, end_datetime=end_datetime, interval=interval)
|
||||||
expected = np.zeros(3) # No data, so all intervals are zero
|
# No data: the load of every interval is unknown, not zero.
|
||||||
np.testing.assert_array_equal(result, expected)
|
assert result.shape == (3,)
|
||||||
|
assert np.isnan(result).all()
|
||||||
|
|
||||||
async def test_load_total_kwh_partial_intervals(self, measurement_eos):
|
async def test_load_total_kwh_partial_intervals(self, measurement_eos):
|
||||||
"""Test total load calculation with partial intervals."""
|
"""Test total load calculation with partial intervals."""
|
||||||
|
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||||
start_datetime = to_datetime("2023-01-01T00:30:00") # Start in the middle of an interval
|
start_datetime = to_datetime("2023-01-01T00:30:00") # Start in the middle of an interval
|
||||||
end_datetime = to_datetime("2023-01-01T01:30:00") # End in the middle of another interval
|
end_datetime = to_datetime("2023-01-01T01:30:00") # End in the middle of another interval
|
||||||
interval = duration(hours=1)
|
interval = duration(hours=1)
|
||||||
@@ -390,6 +464,60 @@ class TestMeasurement:
|
|||||||
np.testing.assert_array_equal(result, expected)
|
np.testing.assert_array_equal(result, expected)
|
||||||
|
|
||||||
|
|
||||||
|
async def test_load_total_kwh_follows_a_jittered_meter(self, measurement_eos):
|
||||||
|
"""Hourly load energy is exact for a meter reporting at arbitrary stamps.
|
||||||
|
|
||||||
|
The meter reports every ~5 minutes off the hour. Load is 1 kW until noon and
|
||||||
|
3 kW afterwards; each hour must get exactly its own energy, also around the step.
|
||||||
|
"""
|
||||||
|
measurement_eos.config.measurement.load_emr_keys = ["load_jitter_mr"]
|
||||||
|
start = to_datetime("2023-02-01T00:00:00Z")
|
||||||
|
jitter = [0, 21, 47, 13, 34]
|
||||||
|
stamp = to_datetime("2023-01-31T23:57:10Z")
|
||||||
|
energy_kwh = 0.0
|
||||||
|
step = 0
|
||||||
|
while compare_datetimes(stamp, to_datetime("2023-02-02T00:15:00Z")).lt:
|
||||||
|
await measurement_eos.update_value(stamp, "load_jitter_mr", round(energy_kwh, 6))
|
||||||
|
following = stamp.add(minutes=5, seconds=jitter[step % len(jitter)])
|
||||||
|
noon = to_datetime("2023-02-01T12:00:00Z")
|
||||||
|
seconds_before_noon = max(0.0, min(following.timestamp(), noon.timestamp()) - stamp.timestamp())
|
||||||
|
seconds_after_noon = (following.timestamp() - stamp.timestamp()) - seconds_before_noon
|
||||||
|
energy_kwh += (1.0 * seconds_before_noon + 3.0 * seconds_after_noon) / 3600.0
|
||||||
|
stamp = following
|
||||||
|
step += 1
|
||||||
|
|
||||||
|
result = await measurement_eos.load_total_kwh(
|
||||||
|
start_datetime=start, end_datetime=start.add(days=1), interval=to_duration("1 hour")
|
||||||
|
)
|
||||||
|
|
||||||
|
# Away from the step every hour is exact. The step lies inside one ~5-minute
|
||||||
|
# reading interval, which a meter cannot resolve: hours 11 and 12 share it, but
|
||||||
|
# keep their sum (a bucket-mean conversion moves about half an hour across).
|
||||||
|
np.testing.assert_allclose(result[:11], 1.0, atol=1e-5)
|
||||||
|
np.testing.assert_allclose(result[13:], 3.0, atol=1e-5)
|
||||||
|
assert result[11] == pytest.approx(1.0, abs=0.05)
|
||||||
|
assert result[12] == pytest.approx(3.0, abs=0.05)
|
||||||
|
assert result[11] + result[12] == pytest.approx(4.0, abs=1e-5)
|
||||||
|
|
||||||
|
async def test_load_total_kwh_is_nan_without_full_coverage(self, measurement_eos):
|
||||||
|
"""An hour a load meter does not fully cover is unknown, not zero load."""
|
||||||
|
result = await measurement_eos.load_total_kwh(
|
||||||
|
start_datetime=to_datetime("2023-01-01T03:00:00"),
|
||||||
|
end_datetime=to_datetime("2023-01-01T07:00:00"),
|
||||||
|
interval=to_duration("1 hour"),
|
||||||
|
)
|
||||||
|
|
||||||
|
# load2_mr and load3_mr are configured but never report.
|
||||||
|
assert np.isnan(result).all()
|
||||||
|
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
|
||||||
|
result = await measurement_eos.load_total_kwh(
|
||||||
|
start_datetime=to_datetime("2023-01-01T03:00:00"),
|
||||||
|
end_datetime=to_datetime("2023-01-01T07:00:00"),
|
||||||
|
interval=to_duration("1 hour"),
|
||||||
|
)
|
||||||
|
np.testing.assert_array_equal(result, [100.0, 100.0, np.nan, np.nan])
|
||||||
|
|
||||||
|
|
||||||
class TestMeasurementFileRestore:
|
class TestMeasurementFileRestore:
|
||||||
@pytest.fixture
|
@pytest.fixture
|
||||||
def file_measurements(self, config_eos, tmp_path, monkeypatch):
|
def file_measurements(self, config_eos, tmp_path, monkeypatch):
|
||||||
@@ -546,3 +674,62 @@ class TestMeasurementChannels:
|
|||||||
measurement.records = previous_records
|
measurement.records = previous_records
|
||||||
config_eos.measurement = previous_settings
|
config_eos.measurement = previous_settings
|
||||||
config_eos.general.data_folder_path = previous_folder
|
config_eos.general.data_folder_path = previous_folder
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
class TestMeasurementCommonPeriod:
|
||||||
|
"""Common period of a meter group and its warnings."""
|
||||||
|
|
||||||
|
@pytest_asyncio.fixture
|
||||||
|
async def measurement(self, config_eos):
|
||||||
|
# Configured meter keys are writable record keys of the store.
|
||||||
|
config_eos.measurement.load_emr_keys = ["meter_a_mr", "meter_b_mr"]
|
||||||
|
measurement = get_measurement()
|
||||||
|
await measurement.delete_by_datetime(None, None)
|
||||||
|
measurement._reported_warnings.clear()
|
||||||
|
yield measurement
|
||||||
|
await measurement.delete_by_datetime(None, None)
|
||||||
|
measurement._reported_warnings.clear()
|
||||||
|
|
||||||
|
@staticmethod
|
||||||
|
def warnings(caplog, text: str) -> int:
|
||||||
|
return sum(
|
||||||
|
record.levelname == "WARNING" and text in record.getMessage()
|
||||||
|
for record in caplog.records
|
||||||
|
)
|
||||||
|
|
||||||
|
async def test_silent_group_is_warned_again_after_it_reported(self, measurement, caplog):
|
||||||
|
keys = ["meter_a_mr", "meter_b_mr"]
|
||||||
|
start = to_datetime("2024-01-01T00:00:00Z")
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
assert await measurement.keys_common_period(keys, "test") is None
|
||||||
|
first = self.warnings(caplog, "have no valid readings")
|
||||||
|
for hour in range(3):
|
||||||
|
for key in keys:
|
||||||
|
await measurement.update_value(start.add(hours=hour), key, 10.0 + hour)
|
||||||
|
assert await measurement.keys_common_period(keys, "test") is not None
|
||||||
|
await measurement.delete_by_datetime(None, None)
|
||||||
|
assert await measurement.keys_common_period(keys, "test") is None
|
||||||
|
|
||||||
|
assert first > 0
|
||||||
|
assert self.warnings(caplog, "have no valid readings") > first
|
||||||
|
|
||||||
|
async def test_single_reading_is_no_replaced_meter(self, measurement, caplog):
|
||||||
|
await measurement.update_value(to_datetime("2024-01-01T00:00:00Z"), "meter_a_mr", 10.0)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
assert await measurement.keys_common_period(["meter_a_mr"], "test") is None
|
||||||
|
|
||||||
|
assert self.warnings(caplog, "share no period") == 0
|
||||||
|
|
||||||
|
async def test_touching_replacement_is_a_replaced_meter(self, measurement, caplog):
|
||||||
|
"""A swap where the new meter starts at the old meter's last stamp is named."""
|
||||||
|
start = to_datetime("2024-01-01T00:00:00Z")
|
||||||
|
for hour in range(4):
|
||||||
|
await measurement.update_value(start.add(hours=hour), "meter_a_mr", 10.0 + hour)
|
||||||
|
await measurement.update_value(start.add(hours=3 + hour), "meter_b_mr", 50.0 + hour)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
assert await measurement.keys_common_period(["meter_a_mr", "meter_b_mr"], "test") is None
|
||||||
|
|
||||||
|
assert self.warnings(caplog, "meter 'meter_a_mr' last reported at") > 0
|
||||||
|
|||||||
@@ -8,8 +8,9 @@ from zoneinfo import ZoneInfo
|
|||||||
|
|
||||||
import pytest
|
import pytest
|
||||||
|
|
||||||
from akkudoktoreos.measurement.energy import energy_intervals
|
from akkudoktoreos.measurement.energy import energy_intervals, valid_reading
|
||||||
from akkudoktoreos.measurement.measurement import MeasurementChannelSettings
|
from akkudoktoreos.measurement.measurement import MeasurementChannelSettings
|
||||||
|
from akkudoktoreos.measurement.quality import SampleQuality
|
||||||
from akkudoktoreos.utils.datetimeutil import to_datetime
|
from akkudoktoreos.utils.datetimeutil import to_datetime
|
||||||
|
|
||||||
START = datetime(2026, 9, 10, tzinfo=timezone.utc)
|
START = datetime(2026, 9, 10, tzinfo=timezone.utc)
|
||||||
@@ -133,3 +134,22 @@ async def test_measurement_wrapper_preserves_asynchronous_channels(config_eos):
|
|||||||
measurement._db_reset_state()
|
measurement._db_reset_state()
|
||||||
measurement.records = records
|
measurement.records = records
|
||||||
config_eos.measurement = previous
|
config_eos.measurement = previous
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.parametrize(
|
||||||
|
("value", "quality", "expected"),
|
||||||
|
[
|
||||||
|
(1, None, 1.0),
|
||||||
|
(2.5, SampleQuality(status="estimated"), 2.5),
|
||||||
|
(2.5, SampleQuality(status="invalid"), None),
|
||||||
|
(2.5, SampleQuality(status="unavailable"), None),
|
||||||
|
(True, None, None),
|
||||||
|
(float("nan"), None, None),
|
||||||
|
(float("inf"), None, None),
|
||||||
|
(None, None, None),
|
||||||
|
("1.0", None, None),
|
||||||
|
],
|
||||||
|
)
|
||||||
|
def test_valid_reading(value: Any, quality: SampleQuality | None, expected: float | None) -> None:
|
||||||
|
"""One rule decides which raw readings count, shared by conversion and scans."""
|
||||||
|
assert valid_reading(value, quality) == expected
|
||||||
|
|||||||
@@ -12,6 +12,7 @@ import pytest_asyncio
|
|||||||
import requests
|
import requests
|
||||||
|
|
||||||
from akkudoktoreos.core.coreabc import get_ems, get_measurement, get_prediction
|
from akkudoktoreos.core.coreabc import get_ems, get_measurement, get_prediction
|
||||||
|
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
|
||||||
from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor
|
from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor
|
||||||
from akkudoktoreos.prediction.pvforecastakkudoktorlocal import (
|
from akkudoktoreos.prediction.pvforecastakkudoktorlocal import (
|
||||||
PVForecastAkkudoktorLocal,
|
PVForecastAkkudoktorLocal,
|
||||||
@@ -103,6 +104,8 @@ async def pvforecast_instance(config_eos):
|
|||||||
get_ems().set_start_datetime(START)
|
get_ems().set_start_datetime(START)
|
||||||
await provider.delete_by_datetime()
|
await provider.delete_by_datetime()
|
||||||
await get_measurement().delete_by_datetime()
|
await get_measurement().delete_by_datetime()
|
||||||
|
# Warn-once state lives on the shared singleton; start each test fresh.
|
||||||
|
get_measurement()._reported_warnings.clear()
|
||||||
yield provider
|
yield provider
|
||||||
await provider.delete_by_datetime()
|
await provider.delete_by_datetime()
|
||||||
await get_measurement().delete_by_datetime()
|
await get_measurement().delete_by_datetime()
|
||||||
@@ -404,6 +407,30 @@ async def test_calibration_uses_real_quarter_hour_measurements(pvforecast_instan
|
|||||||
assert "15-minute measurement resolution" in caplog.text or "15-minute intervals" in caplog.text
|
assert "15-minute measurement resolution" in caplog.text or "15-minute intervals" in caplog.text
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_meter_resolution_counts_valid_readings_only(pvforecast_instance):
|
||||||
|
"""Invalid intrahour readings must not make an hourly meter look quarter-hourly.
|
||||||
|
|
||||||
|
Fitting native slots on such a meter would interpolate within each hour and
|
||||||
|
invent a flat intrahour profile.
|
||||||
|
"""
|
||||||
|
key = "pv_hourly_valid_emr"
|
||||||
|
pvforecast_instance.config.measurement.pv_production_emr_keys = [key]
|
||||||
|
start = START.subtract(days=3)
|
||||||
|
samples = []
|
||||||
|
for slot in range(3 * 24 * 4):
|
||||||
|
stamp = start.add(minutes=15 * slot)
|
||||||
|
quality = (
|
||||||
|
SampleQuality(status="measured") if slot % 4 == 0 else SampleQuality(status="invalid")
|
||||||
|
)
|
||||||
|
samples.append(
|
||||||
|
MeasurementSample(date_time=stamp, key=key, value=float(slot), quality=quality)
|
||||||
|
)
|
||||||
|
await get_measurement().import_samples(samples)
|
||||||
|
|
||||||
|
assert await pvforecast_instance._calibration_interval_minutes(start, START) == 60
|
||||||
|
|
||||||
|
|
||||||
@pytest.mark.asyncio
|
@pytest.mark.asyncio
|
||||||
async def test_calibration_factor_is_clamped(pvforecast_instance):
|
async def test_calibration_factor_is_clamped(pvforecast_instance):
|
||||||
"""A wildly wrong meter must not be allowed to swing the forecast."""
|
"""A wildly wrong meter must not be allowed to swing the forecast."""
|
||||||
@@ -1059,3 +1086,76 @@ async def test_snow_feedback_window_is_on_the_slot_grid(pvforecast_instance, rec
|
|||||||
assert end.timestamp() % 900 == 0
|
assert end.timestamp() % 900 == 0
|
||||||
assert compare_datetimes(end, pv_window.last).le
|
assert compare_datetimes(end, pv_window.last).le
|
||||||
assert compare_datetimes(end.add(minutes=15), pv_window.last).gt
|
assert compare_datetimes(end.add(minutes=15), pv_window.last).gt
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_calibration_falls_back_when_the_meter_conversion_fails(
|
||||||
|
pvforecast_instance, monkeypatch, caplog
|
||||||
|
):
|
||||||
|
"""A broken PV meter history disables calibration instead of the forecast."""
|
||||||
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(snow_enabled=True)
|
||||||
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
||||||
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
||||||
|
await _feed_meters(pvforecast_instance, {"pv_broken_emr": meter})
|
||||||
|
|
||||||
|
async def failing_production_total_kwh(self, start_datetime, end_datetime, interval):
|
||||||
|
raise ValueError("Overlapping source energy intervals.")
|
||||||
|
|
||||||
|
monkeypatch.setattr(
|
||||||
|
PVForecastAkkudoktorLocal, "_pv_production_total_kwh", failing_production_total_kwh
|
||||||
|
)
|
||||||
|
|
||||||
|
with caplog.at_level("ERROR"):
|
||||||
|
forecast = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
||||||
|
calibration = await _fit(pvforecast_instance, frame)
|
||||||
|
|
||||||
|
assert calibration is None
|
||||||
|
np.testing.assert_allclose(forecast["ac_power"], frame["ac_power"])
|
||||||
|
assert "calibration: PV meter energy conversion failed" in caplog.text
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_calibration_warns_about_a_stale_common_meter_period(pvforecast_instance, caplog):
|
||||||
|
"""A PV meter that stopped reporting holds the fit on old data - say so."""
|
||||||
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
||||||
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
||||||
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
||||||
|
await _feed_meters(pvforecast_instance, {"pv_stale_emr": meter})
|
||||||
|
|
||||||
|
def stale_warnings() -> int:
|
||||||
|
return sum(
|
||||||
|
record.levelname == "WARNING"
|
||||||
|
and "meter 'pv_stale_emr' last reported at" in record.getMessage()
|
||||||
|
for record in caplog.records
|
||||||
|
)
|
||||||
|
|
||||||
|
with caplog.at_level("WARNING"):
|
||||||
|
get_ems().set_start_datetime(START.add(hours=12))
|
||||||
|
await _fit(pvforecast_instance, frame)
|
||||||
|
fresh = stale_warnings()
|
||||||
|
get_ems().set_start_datetime(START.add(days=3))
|
||||||
|
calibration = await _fit(pvforecast_instance, frame)
|
||||||
|
first_stale_run = stale_warnings()
|
||||||
|
await _fit(pvforecast_instance, frame)
|
||||||
|
|
||||||
|
_assert_fitted_bias(calibration, 0.8)
|
||||||
|
assert fresh == 0
|
||||||
|
assert first_stale_run > 0
|
||||||
|
# Once per stale period, not on every run.
|
||||||
|
assert stale_warnings() == first_stale_run
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_pv_meter_window_skips_readings_that_vanish_between_scans(
|
||||||
|
pvforecast_instance, monkeypatch
|
||||||
|
):
|
||||||
|
"""Readings removed between the first and last scan give no window, not an error."""
|
||||||
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
||||||
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
||||||
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
||||||
|
await _feed_meters(pvforecast_instance, {"pv_vanishing_emr": meter})
|
||||||
|
monkeypatch.setattr(
|
||||||
|
type(get_measurement()), "keys_last_datetime", AsyncMock(return_value={})
|
||||||
|
)
|
||||||
|
|
||||||
|
assert await pvforecast_instance._pv_measurement_window() is None
|
||||||
|
|||||||
@@ -390,9 +390,39 @@ async def test_stale_meter_readings_are_reported(snow_instance, caplog):
|
|||||||
await feed_meter("stale", fixture, local("2026-02-20 09:00"))
|
await feed_meter("stale", fixture, local("2026-02-20 09:00"))
|
||||||
get_ems().set_start_datetime(local("2026-02-20 15:00"))
|
get_ems().set_start_datetime(local("2026-02-20 15:00"))
|
||||||
|
|
||||||
await snow_instance._forecast_frame(fixture["openmeteo"])
|
def stale_levels() -> set[str]:
|
||||||
|
return {
|
||||||
|
record.levelname for record in caplog.records if "older than 3 h" in record.getMessage()
|
||||||
|
}
|
||||||
|
|
||||||
assert "older than 3 h" in caplog.text
|
with caplog.at_level("DEBUG"):
|
||||||
|
await snow_instance._forecast_frame(fixture["openmeteo"])
|
||||||
|
assert stale_levels() == {"WARNING"}
|
||||||
|
caplog.clear()
|
||||||
|
# Reported once per stale reading, not on every forecast run.
|
||||||
|
await snow_instance._forecast_frame(fixture["openmeteo"])
|
||||||
|
assert stale_levels() == {"DEBUG"}
|
||||||
|
|
||||||
|
|
||||||
|
@pytest.mark.asyncio
|
||||||
|
async def test_missing_meter_period_is_warned_once(snow_instance, caplog):
|
||||||
|
"""Without a PV meter period only the meter lookup warns, once, not snow feedback."""
|
||||||
|
fixture = load_fixture()
|
||||||
|
get_measurement()._reported_warnings.clear()
|
||||||
|
snow_instance.config.measurement.pv_production_emr_keys = ["silent"]
|
||||||
|
get_ems().set_start_datetime(local("2026-02-20 15:00"))
|
||||||
|
|
||||||
|
def warnings() -> set[str]:
|
||||||
|
return {r.getMessage() for r in caplog.records if r.levelname == "WARNING"}
|
||||||
|
|
||||||
|
with caplog.at_level("DEBUG"):
|
||||||
|
await snow_instance._forecast_frame(fixture["openmeteo"])
|
||||||
|
(message,) = warnings()
|
||||||
|
assert "'silent'" in message and "no valid readings" in message
|
||||||
|
caplog.clear()
|
||||||
|
# The lasting condition is not warned about again on the next forecast run.
|
||||||
|
await snow_instance._forecast_frame(fixture["openmeteo"])
|
||||||
|
assert warnings() == set()
|
||||||
|
|
||||||
|
|
||||||
# ---------------------------------------------------------------- calibration
|
# ---------------------------------------------------------------- calibration
|
||||||
|
|||||||
Reference in New Issue
Block a user