fix(measurement): use quality-aware meter energy for load and PV

Additional fixes
Measurement.meter_energy_kwh converts meter energy over the whole period in one read; the 31-day and 10000-interval limits apply to the public energy queries only.
Load intervals a meter does not fully cover are NaN and the load adjustment skips them; load_total_kwh returns an empty array for an empty store and keeps full last intervals.
The load adjustment compares over the period the load meters report, skips a stale load meter period and says when no load meter is configured.
PV calibration, snow feedback and the load adjustment fall back without measurements when a conversion fails, logged as error once per failure streak and consumer.
Measurement.keys_first_datetime and keys_last_datetime find each meter's first and last valid reading in bounded scans, keep each meter's newest reading and return stamps in the configured zone.
Measurement.keys_common_period derives the common meter period for PV calibration and the load adjustment and names the meter that ends it, also when meters share no period.
PV calibration warns once per stale period when a stopped PV meter holds it on old data; snow feedback warns once about a stale feedback meter.
Lasting meter conditions (silent, reset, gap, replaced meter, no shared period) are warned once per condition and consumer through one helper and warned again when they recur.
A replaced meter whose readings touch the new one is reported; a single reading is not; a meter group waiting for its second reading is an info once.
The PV meter resolution is detected from valid readings only (pre-existing), using one shared valid-reading rule in energy.py.
Stale meter stamps are compared with compare_datetimes; new meter tests create durations with datetimeutil.
The unused legacy Measurement._energy_from_meter_readings is removed; its test scenarios cover meter_energy_kwh.
The converter's range error no longer mentions the API's 31-day limit, and its duplicate interval check is gone.
Measurement and prediction docs describe the meter coverage rule, even gap spreading and when the load forecast stays unadjusted.
Tests reset the warn-once state of the shared measurement store and restore the EMS start they change.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
Bobby Noelte
2026-11-15 18:30:00 +01:00
co-authored by Claude Opus 5.5
parent 2bfb6eafab
commit f441759dfa
11 changed files with 1161 additions and 301 deletions
+4
View File
@@ -79,6 +79,10 @@ linearly approximated. Storing values between optimization intervals is generall
The EOS measurement store automatically sums all given loads to create a total load value series
for specified intervals, usually one hour. This aggregated data can be used for load predictions.
An interval that the meters do not fully cover (before the first or after the last reading, a meter
reset, or a gap longer than the channel's `max_gap_seconds`) has no value instead of zero load; with
several load meters, all of them must cover it. Without `max_gap_seconds` a gap between two readings
is spread evenly over it. The `LoadAkkudoktorAdjusted` provider skips hours without a value.
:::{admonition} Warning
:class: warning
+7 -1
View File
@@ -579,7 +579,9 @@ The `LoadAkkudoktorAdjusted` provider retrieves generic load data from the local
it to match the annual energy consumption specified in the
`LoadAkkudoktor.loadakkudoktor_year_energy` configuration option. In addition, the provider refines
the forecast by incorporating available measured load data, ensuring a more realistic and
site-specific consumption profile.
site-specific consumption profile. It compares the last 7 days that every configured load meter
reports; if a load meter has no readings or stopped reporting more than 7 days ago, the forecast
stays unadjusted and a warning names the meter.
Prediction keys:
@@ -905,6 +907,10 @@ keys in `measurement.pv_production_emr_keys` to fit the model against measuremen
Calibration preserves daily energy while optionally correcting the intraday
azimuth shape, clamps correction factors and respects inverter capacity.
Hourly meters are fitted hourly; native quarter-hour meters retain their cadence.
Meters may report at any time stamps: each interval gets the energy interpolated at its
boundaries. With several PV meters only the period all of them report is fitted, and
intervals a meter does not fully cover (a reset, or a gap longer than the channel's
`max_gap_seconds`) are skipped.
Probable outage or curtailment days are excluded by default. Without sufficient
usable measurements the uncalibrated physical model is used.
+26 -12
View File
@@ -40,6 +40,27 @@ def _date(value: float) -> datetime:
return datetime.fromtimestamp(value, timezone.utc)
def valid_reading(value: object, quality: SampleQuality | None = None) -> float | None:
"""Value of a raw reading that counts as a valid observation.
A reading counts when it is a finite number (not a bool) whose sample quality is
neither invalid nor unavailable. The energy conversion, the meter period scans
and the meter resolution detection share this rule.
Args:
value: Raw stored reading.
quality: Sample quality of the reading, None for the default (measured).
Returns:
The reading as float, or None when it does not count.
"""
if isinstance(value, bool) or not isinstance(value, (int, float)) or not isfinite(value):
return None
if quality is not None and quality.status in ("invalid", "unavailable"):
return None
return float(value)
def energy_intervals(
samples: Iterable[tuple[datetime, float | None]],
channel: "MeasurementChannelSettings",
@@ -66,10 +87,9 @@ def energy_intervals(
def sample_quality(time: float) -> SampleQuality:
return quality.get(time, SampleQuality())
def number(value: float | None) -> float | None:
if isinstance(value, bool) or not isinstance(value, (int, float)) or not isfinite(value):
return None
return float(value) * scale
def number(value: float | None, sample: SampleQuality) -> float | None:
reading = valid_reading(value, sample)
return None if reading is None else reading * scale
# Segment: start, end, start/end power in W, method, error flag.
segments = []
@@ -84,21 +104,15 @@ def energy_intervals(
if previous_end is not None and a < previous_end:
raise ValueError("Overlapping source energy intervals.")
previous_end = b
value = number(raw)
if sample_quality(time).status in ("invalid", "unavailable"):
value = None
value = number(raw, sample_quality(time))
power = value * 3600 / duration if value is not None else None
segments.append(
(a, b, power, power, "interval_energy", "invalid_sample" if power is None else None)
)
else:
for (a, raw_a), (b, raw_b) in zip(points, points[1:]):
va, vb = number(raw_a), number(raw_b)
qa, qb = sample_quality(a), sample_quality(b)
if qa.status in ("invalid", "unavailable"):
va = None
if qb.status in ("invalid", "unavailable"):
vb = None
va, vb = number(raw_a, qa), number(raw_b, qb)
flag = None
if channel.max_gap_seconds is not None and b - a > channel.max_gap_seconds:
flag = "gap_too_large"
+369 -96
View File
@@ -8,6 +8,8 @@ The measurements can be added programmatically or imported from a file or JSON s
import json
from bisect import bisect_left, bisect_right
from collections.abc import Iterable
from dataclasses import dataclass
from datetime import datetime, timedelta
from pathlib import Path
from typing import Any, Callable, Literal, Optional
@@ -26,16 +28,36 @@ from akkudoktoreos.measurement.batterycapacity import (
BatteryCapacityRequest,
estimate_capacity,
)
from akkudoktoreos.measurement.energy import EnergyInterval
from akkudoktoreos.measurement.energy import EnergyInterval, valid_reading
from akkudoktoreos.measurement.household import HouseholdSettings, household_intervals
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
from akkudoktoreos.utils.datetimeutil import (
DateTime,
Duration,
compare_datetimes,
to_datetime,
to_duration,
)
# Limits of one quality-aware energy query (`Measurement.energy_intervals`).
ENERGY_QUERY_MAX_SECONDS = 31 * 86400
ENERGY_QUERY_MAX_INTERVALS = 10000
@dataclass(frozen=True)
class MeterPeriod:
"""Period that every meter of a group reports.
Attributes:
first: Latest first valid reading across the meters.
last: Earliest last valid reading across the meters.
last_key: Meter whose last reading ends the period.
"""
first: DateTime
last: DateTime
last_key: str
class MeasurementChannelSettings(SettingsBaseModel):
"""Meaning of a raw measurement channel; no conversion is performed on storage."""
@@ -209,6 +231,55 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
return
super().__init__(*args, **kwargs)
@property
def _reported_warnings(self) -> set[str]:
"""Topics of conditions already warned about; see `_warn_once`.
Created lazily and cached on the instance, like the record locks.
"""
try:
return object.__getattribute__(self, "_reported_warnings_instance")
except AttributeError:
reported: set[str] = set()
object.__setattr__(self, "_reported_warnings_instance", reported)
return reported
def _warn_once(self, topics: str | Iterable[str], message: str, level: str = "WARNING") -> None:
"""Log a lasting condition once at ``level``, then as debug until it clears.
Args:
topics: Identity of the condition, e.g. ``"meter-silent:<consumer>:<key>"``;
several topics log at ``level`` when any of them is new.
message: Log message.
level: Log level of the first message.
"""
topic_set = {topics} if isinstance(topics, str) else set(topics)
if topic_set <= self._reported_warnings:
logger.debug(message)
else:
self._reported_warnings.update(topic_set)
logger.log(level, message)
def _clear_warning(self, topic: str) -> None:
"""Forget a condition, so it is warned about again when it comes back."""
self._reported_warnings.discard(topic)
def report_conversion_failure(self, consumer: str, message: str) -> None:
"""Log a failed meter energy conversion of ``consumer`` once per failure streak.
The first failure logs as error, repeated failures as debug until
`clear_conversion_failure` reports a successful conversion.
Args:
consumer: Conversion path, e.g. ``"LoadAkkudoktorAdjusted"``.
message: Log message, including the conversion error.
"""
self._warn_once(f"conversion-failed:{consumer}", message, level="ERROR")
def clear_conversion_failure(self, consumer: str) -> None:
"""End the failure streak of ``consumer`` after a successful conversion."""
self._clear_warning(f"conversion-failed:{consumer}")
def _measurement_file_path(self) -> Optional[Path]:
"""Path to measurements file (may be used optional to database)."""
try:
@@ -291,14 +362,25 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
start: datetime,
end: datetime,
) -> Callable[[str, datetime, datetime, int], list[EnergyInterval]]:
"""Load a bounded window once, including configured boundary context."""
"""Load a window once, including configured boundary context.
The query limits that protect the API are checked by the public wrappers
(`_check_energy_query`), not here.
Args:
keys: Energy channels to convert.
start: Start of the window.
end: End of the window.
Returns:
Converter from a channel and a sub-window to energy intervals.
"""
from akkudoktoreos.measurement.energy import energy_intervals
if any(dt.tzinfo is None or dt.utcoffset() is None for dt in (start, end)):
raise ValueError("Explicit timezone required.")
seconds = end.timestamp() - start.timestamp()
if not 0 < seconds <= 31 * 86400:
raise ValueError("Energy queries require a positive range of at most 31 days.")
if compare_datetimes(to_datetime(end), to_datetime(start)).le:
raise ValueError("Energy queries require a positive range.")
channels = {key: self._energy_channel(key) for key in keys}
context = self.config.measurement.energy_context_seconds
records = [
@@ -339,10 +421,6 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
def convert(
key: str, left: datetime, right: datetime, interval_seconds: int
) -> list[EnergyInterval]:
if type(interval_seconds) is not int or interval_seconds <= 0:
raise ValueError("Positive integer interval_seconds required.")
if (right.timestamp() - left.timestamp()) / interval_seconds > 10000:
raise ValueError("At most 10000 output intervals per query.")
lo = max(0, bisect_left(timestamps[key], left.timestamp()) - 1)
hi = bisect_right(timestamps[key], right.timestamp()) + 1
return energy_intervals(
@@ -351,6 +429,21 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
return convert
@staticmethod
def _check_energy_query(start: datetime, end: datetime, interval_seconds: int) -> None:
"""Enforce the limits of one public energy query (31 days, 10000 intervals).
Raises:
ValueError: If the query exceeds a limit.
"""
seconds = to_datetime(start).diff(to_datetime(end), False).total_seconds()
if not 0 < seconds <= ENERGY_QUERY_MAX_SECONDS:
raise ValueError("Energy queries require a positive range of at most 31 days.")
if type(interval_seconds) is not int or interval_seconds <= 0:
raise ValueError("Positive integer interval_seconds required.")
if seconds / interval_seconds > ENERGY_QUERY_MAX_INTERVALS:
raise ValueError("At most 10000 output intervals per query.")
async def household_intervals(
self, start_datetime: datetime, end_datetime: datetime, interval_seconds: int = 900
) -> dict[str, list[EnergyInterval]]:
@@ -360,6 +453,7 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
raise ValueError("No household balance configured.")
# Revalidate references even after an in-place configuration mutation.
settings = HouseholdSettings.model_validate(settings.model_dump())
self._check_energy_query(start_datetime, end_datetime, interval_seconds)
convert = await self._energy_converter(
[item.key for item in settings.inputs], start_datetime, end_datetime
)
@@ -374,14 +468,243 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
end_datetime: datetime,
interval_seconds: int = 900,
) -> list[EnergyInterval]:
"""Convert a typed channel without changing the legacy kWh calculation.
"""Convert a typed channel; load and PV energy use the same conversion.
Read only explicitly stored values for this key: another channel's timestamp
must not introduce a synthetic outage. Explicit null values remain barriers.
"""
self._check_energy_query(start_datetime, end_datetime, interval_seconds)
convert = await self._energy_converter([key], start_datetime, end_datetime)
return convert(key, start_datetime, end_datetime, interval_seconds)
async def meter_energy_kwh(
self,
keys: list[str],
start_datetime: DateTime,
end_datetime: DateTime,
interval: Duration,
) -> dict[str, NDArray[Shape["*"], float]]:
"""Energy per interval of energy channels, read from the store once.
Uses the quality-aware conversion (`energy_intervals`): a cumulative meter is
interpolated at the interval boundaries, so a meter reporting at arbitrary
stamps yields exactly the energy of each interval. The records of the whole
period are loaded once for all channels, so a gap converts the same way
wherever it lies in the period.
Args:
keys: Energy channels, e.g. configured meter reading keys.
start_datetime: Start of the first interval; intervals start here.
end_datetime: End of the period. A last partial interval is extended to a
full interval.
interval: Interval length, a positive whole number of seconds.
Returns:
Energy in kWh per interval for each key, NaN where the channel does not
fully cover the interval (before its first or after its last reading, a
reset, or a gap longer than the channel's ``max_gap_seconds``).
Raises:
ValueError: If the period or interval is invalid or a key has no energy
channel definition.
"""
interval_seconds = int(interval.total_seconds())
if interval_seconds <= 0 or interval_seconds != interval.total_seconds():
raise ValueError("Interval must be a positive whole number of seconds.")
size = self._interval_count(start_datetime, end_datetime, interval)
if size == 0:
return {key: np.zeros(0) for key in keys}
period_end = start_datetime.add(seconds=size * interval_seconds)
convert = await self._energy_converter(keys, start_datetime, period_end)
return {
key: np.asarray(
[
np.nan if slot.energy_wh is None else slot.energy_wh / 1000.0
for slot in convert(key, start_datetime, period_end, interval_seconds)
],
dtype=float,
)
for key in keys
}
def _valid_reading_keys(self, record: MeasurementDataRecord, keys: Iterable[str]) -> list[str]:
"""Keys of ``record`` that carry a valid reading.
Uses the reading rule of the energy conversion (`valid_reading`).
"""
if record.date_time is None:
return []
return [
key
for key in keys
if valid_reading(record.configured_data.get(key), record.sample_quality.get(key))
is not None
]
async def keys_valid_datetimes(
self, keys: list[str], start_datetime: DateTime, end_datetime: DateTime
) -> dict[str, list[DateTime]]:
"""Stamps of the valid readings per key in a period, read in one pass.
Unlike `key_to_lists`, readings whose sample quality is invalid or unavailable
do not count (`valid_reading`), as for the energy conversion.
Args:
keys: Record keys, e.g. meter reading keys.
start_datetime: Start of the period (inclusive).
end_datetime: End of the period (exclusive).
Returns:
Ascending stamps per key, empty for a key without valid readings.
"""
stamps: dict[str, list[DateTime]] = {key: [] for key in keys}
async for record in self.db_iterate_records(
DatabaseTimestamp.from_datetime(start_datetime),
DatabaseTimestamp.from_datetime(end_datetime),
):
for key in self._valid_reading_keys(record, keys):
stamps[key].append(to_datetime(record.date_time))
return stamps
async def keys_first_datetime(self, keys: list[str]) -> dict[str, DateTime]:
"""First stamp with a valid reading per key, in one forward pass.
Scans forward from the oldest record in windows that double in size and stops
once every key is found, instead of reading the keys' whole history.
Args:
keys: Record keys, e.g. meter reading keys.
Returns:
First stamp per key, in the configured timezone like `min_datetime`; keys
without a valid reading are missing.
"""
timezone = self.config.general.timezone
wanted = set(keys)
firsts: dict[str, DateTime] = {}
oldest = await self.min_datetime()
newest = await self.max_datetime()
if not wanted or oldest is None or newest is None:
return firsts
end_of_store = newest.add(seconds=1)
step_seconds = 86400
window_start = oldest
while len(firsts) < len(wanted) and compare_datetimes(window_start, end_of_store).lt:
window_end = window_start.add(seconds=step_seconds)
async for record in self.db_iterate_records(
DatabaseTimestamp.from_datetime(window_start),
DatabaseTimestamp.from_datetime(window_end),
):
for key in self._valid_reading_keys(record, wanted - firsts.keys()):
firsts[key] = to_datetime(record.date_time, in_timezone=timezone)
window_start = window_end
step_seconds *= 2
return firsts
async def keys_last_datetime(self, keys: list[str]) -> dict[str, DateTime]:
"""Last stamp with a valid reading per key, in one backward pass.
Scans backward from the newest record in windows that double in size and
stops once every key is found.
Args:
keys: Record keys, e.g. meter reading keys.
Returns:
Last stamp per key, in the configured timezone like `max_datetime`; keys
without a valid reading are missing.
"""
timezone = self.config.general.timezone
wanted = set(keys)
lasts: dict[str, DateTime] = {}
oldest = await self.min_datetime()
newest = await self.max_datetime()
if not wanted or oldest is None or newest is None:
return lasts
step_seconds = 86400
window_end = newest.add(seconds=1)
while len(lasts) < len(wanted) and compare_datetimes(window_end, oldest).gt:
window_start = window_end.subtract(seconds=step_seconds)
# Newest valid reading per key in this window; keys found in a newer
# window keep their stamp.
window_lasts: dict[str, DateTime] = {}
async for record in self.db_iterate_records(
DatabaseTimestamp.from_datetime(window_start),
DatabaseTimestamp.from_datetime(window_end),
):
for key in self._valid_reading_keys(record, wanted - lasts.keys()):
window_lasts[key] = to_datetime(record.date_time, in_timezone=timezone)
lasts.update(window_lasts)
window_end = window_start
step_seconds *= 2
return lasts
async def keys_common_period(self, keys: list[str], consumer: str) -> Optional[MeterPeriod]:
"""Period that every meter in ``keys`` covers with valid readings.
Outside this period a sum over the meters is not the total they measure.
Logs why there is none, once per condition until it clears: a meter without
valid readings (e.g. a mistyped key) and meters that share no period (e.g. a
replaced meter still configured) are warnings; a single reading so far is an
info.
Args:
keys: Meter reading keys of one group, e.g. the PV production meters.
consumer: Name used in the log messages and warning topics.
Returns:
The common period, or None when a meter has no valid reading or the meters
share no period.
"""
keys = list(dict.fromkeys(keys))
if not keys:
return None
firsts = await self.keys_first_datetime(keys)
silent = [key for key in keys if key not in firsts]
for key in firsts:
self._clear_warning(f"meter-silent:{consumer}:{key}")
if silent:
self._warn_once(
[f"meter-silent:{consumer}:{key}" for key in silent],
f"{consumer}: meter(s) {silent} have no valid readings (check the keys) - "
"waiting for them.",
)
return None
lasts = await self.keys_last_datetime(keys)
if any(key not in lasts for key in keys):
logger.info(f"{consumer}: meter readings changed while reading them - skipping.")
return None
first_key = keys[0]
last_key = keys[0]
for key in keys[1:]:
if compare_datetimes(firsts[key], firsts[first_key]).gt:
first_key = key
if compare_datetimes(lasts[key], lasts[last_key]).lt:
last_key = key
first, last = firsts[first_key], lasts[last_key]
overlapping = compare_datetimes(first, last).lt
no_period_topic = f"meter-no-period:{consumer}"
if not overlapping and first_key != last_key:
# Two meters that do not report together, e.g. a replaced meter.
self._warn_once(
f"{no_period_topic}:{last_key}",
f"{consumer}: meter '{last_key}' last reported at {last}, before meter "
f"'{first_key}' started at {first} - the meters share no period.",
)
return None
for key in keys:
self._clear_warning(f"{no_period_topic}:{key}")
if not overlapping:
# One meter with a single reading so far (or readings that changed).
self._warn_once(
f"meter-waiting:{consumer}",
f"{consumer}: the meters {keys} have no period yet ({first}) - waiting.",
level="INFO",
)
return None
self._clear_warning(f"meter-waiting:{consumer}")
return MeterPeriod(first=first, last=last, last_key=last_key)
async def estimate_battery_capacity(
self, battery_id: str, request: BatteryCapacityRequest
) -> BatteryCapacityEstimate:
@@ -436,90 +759,37 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
discharging_efficiency=parameters.discharging_efficiency,
)
async def _energy_from_meter_readings(
self,
key: str,
start_datetime: DateTime,
end_datetime: DateTime,
interval: Duration,
) -> NDArray[Shape["*"], Any]:
"""Calculate an energy values array indexed by fixed time intervals from energy metering data within an optional date range.
Args:
key: Key for energy meter readings.
start_datetime (datetime): The start date for filtering the energy data (inclusive).
end_datetime (datetime): The end date for filtering the energy data (exclusive).
interval (duration): The fixed time interval.
Returns:
np.ndarray: A NumPy Array of the energy [kWh] per interval values calculated from
the meter readings.
"""
if start_datetime is None or end_datetime is None:
raise ValueError("Start and end datetimes are required for energy calculation")
size = self._interval_count(start_datetime, end_datetime, interval)
energy_mr_array = await self.key_to_array(
key=key,
start_datetime=start_datetime,
end_datetime=end_datetime + interval,
interval=interval,
fill_method="time",
boundary="context",
)
if energy_mr_array.size != size + 1:
logging_msg = (
f"'{key}' meter reading array size: {energy_mr_array.size}"
f" does not fit to expected size: {size + 1}, {energy_mr_array}"
)
if energy_mr_array.size != 0:
logger.error(logging_msg)
raise ValueError(logging_msg)
logger.debug(logging_msg)
energy_array = np.zeros(size)
elif np.any(energy_mr_array == None):
# 'key_to_array()' creates None values array if no data records are available.
# Array contains None value -> ignore
debug_msg = f"'{key}' meter reading None: {energy_mr_array}"
logger.debug(debug_msg)
energy_array = np.zeros(size)
else:
# Calculate load per interval
debug_msg = f"'{key}' meter reading: {energy_mr_array}"
logger.debug(debug_msg)
energy_array = np.diff(energy_mr_array)
debug_msg = f"'{key}' energy calculation: {energy_array}"
logger.debug(debug_msg)
return energy_array
async def load_total_kwh(
self,
start_datetime: Optional[DateTime] = None,
end_datetime: Optional[DateTime] = None,
interval: Optional[Duration] = None,
) -> NDArray[Shape["*"], Any]:
"""Calculate a total load energy values array indexed by fixed time intervals from load metering data within an optional date range.
) -> NDArray[Shape["*"], float]:
"""Total load energy per interval from the configured load meters.
Each meter is converted with `meter_energy_kwh`: the cumulative reading is
interpolated at the interval boundaries, and an interval a meter does not
fully cover is unknown (NaN), never zero load.
Args:
start_datetime (datetime, optional): The start date for filtering the load data (inclusive).
end_datetime (datetime, optional): The end date for filtering the load data (exclusive).
start_datetime (datetime, optional): Start of the first interval. Defaults
to the first measurement.
end_datetime (datetime, optional): End of the period (exclusive). Defaults to
just after the last measurement.
interval (duration, optional): The fixed time interval. Defaults to 1 hour.
Returns:
np.ndarray: A NumPy Array of the total load energy [kWh] per interval values calculated from
the load meter readings.
np.ndarray: Total load energy [kWh] per interval; NaN where any load meter
lacks full coverage or no load meter is configured.
Raises:
ValueError: If the period cannot be determined or is invalid.
"""
if interval is None:
interval = to_duration("1 hour")
if len(self) < 1:
# No data available
if start_datetime is None or end_datetime is None:
size = 0
else:
size = self._interval_count(start_datetime, end_datetime, interval)
return np.zeros(size)
if len(self) < 1 and (start_datetime is None or end_datetime is None):
# No data and no period: nothing to report.
return np.zeros(0)
if start_datetime is None:
start_datetime = await self.min_datetime()
if end_datetime is None:
@@ -529,23 +799,26 @@ class Measurement(SingletonMixin, DataImportMixin, DataSequence[MeasurementDataR
if start_datetime is None or end_datetime is None:
raise ValueError("Start and end datetimes are required for energy calculation")
size = self._interval_count(start_datetime, end_datetime, interval)
if size == 0:
return np.zeros(0)
load_keys = self.config.measurement.load_emr_keys or []
if not load_keys:
return np.full(size, np.nan)
load_total_kwh_array = np.zeros(size)
# Loop through all loads
if isinstance(self.config.measurement.load_emr_keys, list):
for key in self.config.measurement.load_emr_keys:
# Calculate load per interval
load_array = await self._energy_from_meter_readings(
key=key,
start_datetime=start_datetime,
end_datetime=end_datetime,
interval=interval,
meters_kwh = await self.meter_energy_kwh(load_keys, start_datetime, end_datetime, interval)
for key, meter_kwh in meters_kwh.items():
if np.isnan(meter_kwh).all():
message = (
f"Load meter '{key}' gives no usable energy for {start_datetime} .. "
f"{end_datetime} (no readings, resets or gaps longer than its "
"max_gap_seconds): the total load of this period is unknown."
)
# Add calculated load to total load
load_total_kwh_array += load_array
debug_msg = f"Total load '{key}' calculation: {load_total_kwh_array}"
logger.debug(debug_msg)
self._warn_once(f"meter-unusable:{key}", message)
else:
self._clear_warning(f"meter-unusable:{key}")
load_total_kwh_array += meter_kwh
logger.debug(f"Total load calculation: {load_total_kwh_array}")
return load_total_kwh_array
# ----------------------- Measurement Database Protocol ---------------------
+64 -9
View File
@@ -4,11 +4,19 @@ from typing import Optional
import numpy as np
from loguru import logger
from pydantic import Field
from pydantic import Field, PrivateAttr
from akkudoktoreos.config.configabc import SettingsBaseModel
from akkudoktoreos.prediction.loadabc import LoadDataRecord, LoadProvider
from akkudoktoreos.utils.datetimeutil import compare_datetimes, to_datetime, to_duration
from akkudoktoreos.utils.datetimeutil import (
DateTime,
compare_datetimes,
to_datetime,
to_duration,
)
# The load adjustment ignores meters whose common period ended longer ago than this.
LOAD_ADJUSTMENT_STALE_DAYS = 7
class LoadAkkudoktorCommonSettings(SettingsBaseModel):
@@ -93,6 +101,9 @@ class LoadAkkudoktor(LoadProvider[LoadAkkudoktorDataRecord]):
class LoadAkkudoktorAdjusted(LoadAkkudoktor):
"""Fetch Load forecast data from Akkudoktor load profiles with adjustment by measurements."""
# End of the load meter period last warned about as stale (warned once).
_stale_adjustment_reported_end: Optional[DateTime] = PrivateAttr(default=None)
@classmethod
def provider_id(cls) -> str:
"""Return the unique identifier for the LoadAkkudoktor provider."""
@@ -112,16 +123,42 @@ class LoadAkkudoktorAdjusted(LoadAkkudoktor):
weekend_adjust = np.zeros(24)
weekend_adjust_weight = np.zeros(24)
max_dt = await self.measurement.max_datetime()
if max_dt is None:
# No measurements - return 0 adjustment
return (weekday_adjust, weekday_adjust)
if not self.config.measurement.load_emr_keys:
logger.info(
"LoadAkkudoktorAdjusted: measurement.load_emr_keys is not configured - "
"no load adjustment."
)
return (weekday_adjust, weekend_adjust)
min_dt = await self.measurement.min_datetime()
# Compare against the period every load meter reports, not the whole store:
# other channels (PV, SoC) often reach further than the load meters.
period = await self.measurement.keys_common_period(
self.config.measurement.load_emr_keys, "LoadAkkudoktorAdjusted"
)
if period is None:
return (weekday_adjust, weekend_adjust)
min_dt, max_dt = period.first, period.last
if compare_datetimes(
max_dt.add(days=LOAD_ADJUSTMENT_STALE_DAYS), self.ems_start_datetime
).lt:
# A week that old says nothing about the current load profile.
message = (
f"LoadAkkudoktorAdjusted: load meter '{period.last_key}' last reported at "
f"{max_dt}, more than {LOAD_ADJUSTMENT_STALE_DAYS} days ago - no load "
"adjustment."
)
if (
self._stale_adjustment_reported_end is not None
and compare_datetimes(self._stale_adjustment_reported_end, max_dt).equal
):
logger.debug(message)
else:
self._stale_adjustment_reported_end = max_dt
logger.warning(message)
return (weekday_adjust, weekend_adjust)
# compare predictions with real measurement - try to use last 7 days
# Keep the hourly buckets on full hours: the newest record may be an off-hour
# device state (e.g. SoC stamped with the run time, #1447).
# Keep the hourly buckets on full hours (#1447).
compare_end = max_dt.start_of("hour")
compare_start = compare_end - to_duration("7 days")
if compare_datetimes(compare_start, min_dt).lt:
@@ -134,13 +171,31 @@ class LoadAkkudoktorAdjusted(LoadAkkudoktor):
return (weekday_adjust, weekend_adjust)
compare_interval = to_duration("1 hour")
try:
load_total_kwh_array = await self.measurement.load_total_kwh(
start_datetime=compare_start,
end_datetime=compare_end,
interval=compare_interval,
)
except ValueError as exc:
self.measurement.report_conversion_failure(
"LoadAkkudoktorAdjusted",
f"Load adjustment: load meter energy conversion failed - no adjustment: {exc}",
)
return (weekday_adjust, weekend_adjust)
self.measurement.clear_conversion_failure("LoadAkkudoktorAdjusted")
missing_hours = int(np.isnan(load_total_kwh_array).sum())
if missing_hours:
logger.debug(
f"Load adjustment: {missing_hours} of {len(load_total_kwh_array)} hours lack "
"full load meter coverage and are skipped."
)
compare_dt = compare_start
for i in range(len(load_total_kwh_array)):
if np.isnan(load_total_kwh_array[i]):
# Unknown load (meter gap): no information about this hour.
compare_dt += compare_interval
continue
load_total_wh = load_total_kwh_array[i] * 1000
hour = compare_dt.hour
@@ -41,10 +41,11 @@ import pandas as pd
import pendulum
import requests
from loguru import logger
from pydantic import Field, field_validator, model_validator
from pydantic import Field, PrivateAttr, field_validator, model_validator
from akkudoktoreos.config.configabc import SettingsBaseModel
from akkudoktoreos.core.cache import cache_in_file
from akkudoktoreos.measurement.measurement import MeterPeriod
from akkudoktoreos.prediction.pvforecastabc import (
PVForecastDataRecordT,
PVForecastProvider,
@@ -77,15 +78,15 @@ OPENMETEO_SNOW_VARIABLES = ("snowfall", "snow_depth")
# Snow feedback warns when the newest PV meter reading is older than this.
SNOW_FEEDBACK_STALE_HOURS = 3
# Calibration warns when the common PV meter period ended longer ago than this.
CALIBRATION_STALE_HOURS = 24
# Open-Meteo hard limits for a single forecast request.
MAX_FORECAST_DAYS = 16
MAX_PAST_DAYS = 92
TRANSPOSITION_MODELS = ("isotropic", "klucher", "haydavies", "reindl", "king", "perez")
# The measurement store converts energy for at most 31 days per query.
ENERGY_QUERY_MAX_DAYS = 30
# pvlib SAPM cell temperature parameter set per EOS `mountingplace`.
MOUNTING_TEMPERATURE_MODEL = {
"free": "open_rack_glass_glass",
@@ -93,19 +94,6 @@ MOUNTING_TEMPERATURE_MODEL = {
}
@dataclass(frozen=True)
class PVMeterWindow:
"""Period every configured PV production meter reports.
Attributes:
first: Latest first reading across the PV meters.
last: Earliest last reading across the PV meters.
"""
first: DateTime
last: DateTime
def _utc_timestamp(moment: DateTime | pd.Timestamp) -> pd.Timestamp:
"""Convert a moment to a UTC pandas timestamp.
@@ -589,6 +577,11 @@ class PVForecastAkkudoktorLocalCommonSettings(SettingsBaseModel):
class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
"""Compute the PV forecast locally from Open-Meteo irradiance using pvlib."""
# End of the common PV meter period last warned about as stale (warned once).
_stale_calibration_reported_end: Optional[DateTime] = PrivateAttr(default=None)
# Last PV reading the snow feedback last warned about as stale (warned once).
_stale_snow_reported_end: Optional[DateTime] = PrivateAttr(default=None)
@classmethod
def provider_id(cls) -> str:
"""Return the unique identifier for the PV-Forecast-Provider."""
@@ -1055,7 +1048,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
raw_ac = frame["ac_power"].to_numpy(dtype=float).copy()
# Calibration and snow feedback share one scan of the PV meter readings.
pv_window: Optional[PVMeterWindow] = None
pv_window: Optional[MeterPeriod] = None
if (
calibrate
and self.config.measurement.pv_production_emr_keys
@@ -1133,7 +1126,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
row_start = row_start - pd.Timedelta(minutes=self._settings.resolution_minutes)
return row_start
async def _pv_measurement_window(self) -> Optional[PVMeterWindow]:
async def _pv_measurement_window(self) -> Optional[MeterPeriod]:
"""Period that every configured PV production meter covers with readings.
The measurement store holds every meter, not just the PV ones. Load meters
@@ -1147,48 +1140,25 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
The common period, or None when a PV meter has no readings or the meters
share no period.
"""
measurement = self.measurement
first = await measurement.min_datetime()
last = await measurement.max_datetime()
if first is None or last is None:
return None
common_first: Optional[DateTime] = None
common_last: Optional[DateTime] = None
for key in self.config.measurement.pv_production_emr_keys or []:
dates, _ = await measurement.key_to_lists(
key=key,
start_datetime=first,
end_datetime=last.add(minutes=1),
return await self.measurement.keys_common_period(
self.config.measurement.pv_production_emr_keys or [], "PVForecastAkkudoktorLocal"
)
if not dates:
return None
if common_first is None or compare_datetimes(dates[0], common_first).gt:
common_first = dates[0]
if common_last is None or compare_datetimes(dates[-1], common_last).lt:
common_last = dates[-1]
if common_first is None or common_last is None:
return None
if not compare_datetimes(common_first, common_last).lt:
logger.info(
"PVForecastAkkudoktorLocal: the PV production meters share no measurement "
f"period ({common_first} .. {common_last})."
)
return None
return PVMeterWindow(first=common_first, last=common_last)
async def _calibration_interval_minutes(self, start: Any, end: Any) -> int:
async def _calibration_interval_minutes(self, start: DateTime, end: DateTime) -> int:
"""Use native forecast slots only when every PV meter resolves them.
Interpolating an hourly cumulative meter onto quarter hours would create a
perfectly flat, but invented, intrahour profile. Fall back to hourly fitting
until all configured production meters actually provide native slot readings.
Only valid readings count: a meter that marks its intrahour readings invalid
or unavailable resolves full hours only.
"""
native_minutes = self._settings.resolution_minutes
meter_resolutions: list[float] = []
for key in self.config.measurement.pv_production_emr_keys or []:
dates, _ = await self.measurement.key_to_lists(
key=key, start_datetime=start, end_datetime=end
)
keys = self.config.measurement.pv_production_emr_keys or []
valid_datetimes = await self.measurement.keys_valid_datetimes(keys, start, end)
for key in keys:
dates = valid_datetimes[key]
if len(dates) < 3:
return 60
deltas = np.asarray(
@@ -1290,29 +1260,13 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
keys = self.config.measurement.pv_production_emr_keys or []
if not keys:
return np.asarray([], dtype=float)
interval_seconds = int(interval.total_seconds())
totals: Optional[np.ndarray] = None
for key in keys:
values: list[float] = []
chunk_start = start_datetime
while compare_datetimes(chunk_start, end_datetime).lt:
chunk_end = chunk_start.add(days=ENERGY_QUERY_MAX_DAYS)
if compare_datetimes(chunk_end, end_datetime).gt:
chunk_end = end_datetime
intervals = await self.measurement.energy_intervals(
key, chunk_start, chunk_end, interval_seconds
meters_kwh = await self.measurement.meter_energy_kwh(
keys, start_datetime, end_datetime, interval
)
values.extend(
np.nan if slot.energy_wh is None else slot.energy_wh / 1000.0
for slot in intervals
)
chunk_start = chunk_end
meter_kwh = np.asarray(values, dtype=float)
totals = meter_kwh if totals is None else totals + meter_kwh
return np.asarray(totals, dtype=float)
return np.asarray(sum(meters_kwh.values()), dtype=float)
async def _fit_calibration(
self, frame: pd.DataFrame, pv_window: Optional[PVMeterWindow]
self, frame: pd.DataFrame, pv_window: Optional[MeterPeriod]
) -> Optional[tuple[float, np.ndarray]]:
"""Fit correction factors from measured PV production against the model.
@@ -1344,6 +1298,22 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
logger.info("PVForecastAkkudoktorLocal calibration: no PV measurements yet - skipping.")
return None
pv_min_datetime, reference_end = pv_window.first, pv_window.last
if compare_datetimes(
reference_end.add(hours=CALIBRATION_STALE_HOURS), self.ems_start_datetime
).lt:
message = (
f"PVForecastAkkudoktorLocal calibration: PV production meter "
f"'{pv_window.last_key}' last reported at {reference_end}, more than "
f"{CALIBRATION_STALE_HOURS} h ago - calibration can only use data up to then."
)
if (
self._stale_calibration_reported_end is not None
and compare_datetimes(self._stale_calibration_reported_end, reference_end).equal
):
logger.debug(message)
else:
self._stale_calibration_reported_end = reference_end
logger.warning(message)
lookback_days = settings.calibration_days
if settings.calibration_outage_filter_enabled:
@@ -1374,12 +1344,18 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
return None
start, end = window.start_datetime, window.end_datetime
measured_kwh = np.asarray(
await self._pv_production_total_kwh(
try:
measured_kwh = await self._pv_production_total_kwh(
start_datetime=start, end_datetime=end, interval=interval
),
dtype=float,
)
except ValueError as exc:
self.measurement.report_conversion_failure(
"PVForecastAkkudoktorLocal calibration",
"PVForecastAkkudoktorLocal calibration: PV meter energy conversion failed - "
f"using the uncalibrated model: {exc}",
)
return None
self.measurement.clear_conversion_failure("PVForecastAkkudoktorLocal calibration")
if measured_kwh.size == 0 or not np.isfinite(measured_kwh).any():
logger.info(
"PVForecastAkkudoktorLocal calibration: no usable PV measurements - skipping."
@@ -1799,7 +1775,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
return coverage, corrections
async def _snow_observations(
self, frame: pd.DataFrame, pv_window: Optional[PVMeterWindow]
self, frame: pd.DataFrame, pv_window: Optional[MeterPeriod]
) -> tuple[list[tuple[int, int, float]], Optional[float]]:
"""Measured PV energy per meter interval, mapped onto forecast rows.
@@ -1815,8 +1791,9 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
if not settings.snow_feedback_enabled or not self.config.measurement.pv_production_emr_keys:
return [], None
if pv_window is None:
logger.warning(
"PVForecastAkkudoktorLocal snow feedback: no PV production readings - "
# keys_common_period already logged why, once per condition.
logger.debug(
"PVForecastAkkudoktorLocal snow feedback: no PV meter period - "
"using the weather-only snow model."
)
return [], None
@@ -1824,11 +1801,19 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
if compare_datetimes(
pv_last.add(hours=SNOW_FEEDBACK_STALE_HOURS), self.ems_start_datetime
).lt:
logger.warning(
message = (
f"PVForecastAkkudoktorLocal snow feedback: last PV production reading "
f"{pv_last} is older than {SNOW_FEEDBACK_STALE_HOURS} h - the snow "
"coverage relies on the weather model since then."
)
if (
self._stale_snow_reported_end is not None
and compare_datetimes(self._stale_snow_reported_end, pv_last).equal
):
logger.debug(message)
else:
self._stale_snow_reported_end = pv_last
logger.warning(message)
resolution = pd.Timedelta(minutes=settings.resolution_minutes)
row_start = self._row_start_index(frame)
@@ -1845,14 +1830,20 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
return [], None
start = window.start
measured = np.asarray(
await self._pv_production_total_kwh(
try:
measured = await self._pv_production_total_kwh(
start_datetime=window.start_datetime,
end_datetime=window.end_datetime,
interval=to_duration(f"{interval_minutes} minutes"),
),
dtype=float,
)
except ValueError as exc:
self.measurement.report_conversion_failure(
"PVForecastAkkudoktorLocal snow feedback",
"PVForecastAkkudoktorLocal snow feedback: PV meter energy conversion failed - "
f"using the weather-only snow model: {exc}",
)
return [], None
self.measurement.clear_conversion_failure("PVForecastAkkudoktorLocal snow feedback")
interval_hours = interval_minutes / 60.0
# A meter jump (reset, a sub-meter dropping out of a sum) shows up as an
# impossible yield. Drop it rather than learn snow - or its absence - from it.
@@ -1879,7 +1870,7 @@ class PVForecastAkkudoktorLocal(PVForecastProvider[PVForecastDataRecordT]):
plane_ac: np.ndarray,
plane_poa: np.ndarray,
plane_tilt: np.ndarray,
pv_window: Optional[PVMeterWindow],
pv_window: Optional[MeterPeriod],
) -> pd.DataFrame:
"""Reduce the forecast by the (measurement-corrected) snow coverage."""
settings = self._settings
+181 -1
View File
@@ -49,7 +49,12 @@ def loadakkudoktoradjusted(config_eos):
config_eos.merge_settings_from_dict(settings)
assert config_eos.load.provider == "LoadAkkudoktorAdjusted"
assert config_eos.load.loadakkudoktor.loadakkudoktor_year_energy_kwh == 1000
return LoadAkkudoktorAdjusted()
# The adjustment ignores stale meter periods; run the tests next to their data.
ems_class = type(get_ems())
previous_start = ems_class._start_datetime
get_ems().set_start_datetime(to_datetime("2024-01-02T00:00:00"))
yield LoadAkkudoktorAdjusted()
ems_class._start_datetime = previous_start
@pytest_asyncio.fixture
async def measurement_eos():
@@ -264,6 +269,8 @@ async def empty_measurement(config_eos):
"""Own, empty measurement store (the singleton is shared between tests)."""
measurement = get_measurement()
await measurement.delete_by_datetime(None, None)
# Warn-once state lives on the shared singleton; start each test fresh.
measurement._reported_warnings.clear()
config_eos.merge_settings_from_dict(
{"devices": {"max_batteries": 1, "batteries": {"storage": {"profile_adjustment": {"nominal_capacity_wh": 2000}}}}}
)
@@ -290,6 +297,7 @@ async def _adjustment_window(adjusted, measurement):
@pytest.mark.asyncio
async def test_adjustment_buckets_stay_on_full_hours(loadakkudoktoradjusted, empty_measurement):
"""A newer off-hour record (e.g. a device SoC) must not shift the hourly buckets (#1447)."""
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
dt = to_datetime("2024-01-01T00:00:00")
for hour in range(25):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
@@ -319,3 +327,175 @@ async def test_adjustment_within_first_hour_returns_zero(
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
assert calls == []
assert not weekday.any() and not weekend.any()
@pytest.mark.asyncio
async def test_adjustment_skips_hours_without_load_meter_coverage(
loadakkudoktoradjusted, empty_measurement
):
"""Hours the load meters do not cover are unknown and must not adjust the profile."""
# A Monday, in the zone whose local hours the adjustment buckets.
timezone = loadakkudoktoradjusted.config.general.timezone
dt = to_datetime("2024-01-01T00:00:00", in_timezone=timezone)
for hour in range(13):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
await empty_measurement.update_value(dt.add(hours=hour), "load1_mr", 500.0 + hour)
# Another channel keeps the store going until midnight.
await empty_measurement.update_value(dt.add(hours=24), "storage-soc-factor", 0.42)
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
assert calls
assert np.isfinite(weekday).all() and np.isfinite(weekend).all()
assert (weekday[:12] != 0.0).all()
assert (weekday[12:] == 0.0).all()
@pytest.mark.asyncio
async def test_adjustment_falls_back_when_the_meter_conversion_fails(
loadakkudoktoradjusted, empty_measurement, caplog
):
"""A broken meter history disables the adjustment instead of the load prediction.
The failure is an error once per streak, not on every prediction run.
"""
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
dt = to_datetime("2024-01-01T00:00:00")
for hour in range(25):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
def failure_levels() -> set[str]:
levels = {r.levelname for r in caplog.records if "conversion failed" in r.getMessage()}
caplog.clear()
return levels
with caplog.at_level("DEBUG"):
with patch.object(
type(empty_measurement),
"load_total_kwh",
side_effect=ValueError("Overlapping source energy intervals."),
):
weekday, weekend = await loadakkudoktoradjusted._calculate_adjustment(
np.random.rand(365, 2, 24)
)
assert failure_levels() == {"ERROR"}
await loadakkudoktoradjusted._calculate_adjustment(np.random.rand(365, 2, 24))
assert failure_levels() == {"DEBUG"}
# A successful conversion ends the streak.
await loadakkudoktoradjusted._calculate_adjustment(np.random.rand(365, 2, 24))
with patch.object(
type(empty_measurement),
"load_total_kwh",
side_effect=ValueError("Overlapping source energy intervals."),
):
await loadakkudoktoradjusted._calculate_adjustment(np.random.rand(365, 2, 24))
assert failure_levels() == {"ERROR"}
assert (weekday == 0.0).all() and (weekend == 0.0).all()
@pytest.mark.asyncio
async def test_adjustment_without_load_meters_is_zero(loadakkudoktoradjusted, empty_measurement):
"""Without configured load meters there is nothing to adjust from."""
loadakkudoktoradjusted.config.measurement.load_emr_keys = None
for day in (1, 2):
await empty_measurement.update_value(
to_datetime(f"2024-01-0{day}T00:00:00"), "storage-soc-factor", 0.5
)
(weekday, weekend), calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
assert calls == []
assert (weekday == 0.0).all() and (weekend == 0.0).all()
@pytest.mark.asyncio
async def test_adjustment_window_follows_the_load_meters(
loadakkudoktoradjusted, empty_measurement
):
"""A load meter lagging behind other channels still gives its last 7 days."""
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
dt = to_datetime("2024-01-01T00:00:00")
for hour in range(10 * 24 + 1):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
# SoC keeps reporting three days after the load meter stopped.
await empty_measurement.update_value(dt.add(days=13), "storage-soc-factor", 0.42)
_, calls = await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
assert calls
assert compare_datetimes(calls[0]["end_datetime"], dt.add(days=10)).equal
assert compare_datetimes(calls[0]["start_datetime"], dt.add(days=3)).equal
@pytest.mark.asyncio
async def test_adjustment_ignores_a_stale_load_meter_period(
loadakkudoktoradjusted, empty_measurement, caplog
):
"""A load meter that stopped long ago must not adjust today's profile with old weeks."""
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr"]
dt = to_datetime("2024-01-01T00:00:00")
for hour in range(3 * 24 + 1):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
get_ems().set_start_datetime(dt.add(days=30))
def stale_warnings() -> int:
return sum(
record.levelname == "WARNING"
and "load meter 'load0_mr' last reported at" in record.getMessage()
for record in caplog.records
)
with caplog.at_level("WARNING"):
(weekday, weekend), calls = await _adjustment_window(
loadakkudoktoradjusted, empty_measurement
)
first_run = stale_warnings()
await _adjustment_window(loadakkudoktoradjusted, empty_measurement)
assert calls == []
assert (weekday == 0.0).all() and (weekend == 0.0).all()
assert first_run > 0
assert stale_warnings() == first_run
@pytest.mark.asyncio
async def test_adjustment_names_a_load_meter_without_readings(
loadakkudoktoradjusted, empty_measurement, caplog
):
"""A configured load meter key without readings (e.g. a typo) is named in a warning."""
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr", "load0_mr_typo"]
dt = to_datetime("2024-01-01T00:00:00")
for hour in range(25):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
with caplog.at_level("WARNING"):
(weekday, weekend), calls = await _adjustment_window(
loadakkudoktoradjusted, empty_measurement
)
assert calls == []
assert (weekday == 0.0).all() and (weekend == 0.0).all()
assert "['load0_mr_typo'] have no valid readings" in caplog.text
@pytest.mark.asyncio
async def test_adjustment_names_a_replaced_load_meter(
loadakkudoktoradjusted, empty_measurement, caplog
):
"""Meters that share no period (a replaced meter still configured) are named."""
loadakkudoktoradjusted.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
dt = to_datetime("2024-01-01T00:00:00")
for hour in range(25):
await empty_measurement.update_value(dt.add(hours=hour), "load0_mr", 500.0 + hour)
await empty_measurement.update_value(dt.add(days=2, hours=hour), "load1_mr", 900.0 + hour)
with caplog.at_level("WARNING"):
(weekday, weekend), calls = await _adjustment_window(
loadakkudoktoradjusted, empty_measurement
)
assert calls == []
assert (weekday == 0.0).all() and (weekend == 0.0).all()
assert "meter 'load0_mr' last reported at" in caplog.text
assert "the meters share no period" in caplog.text
+272 -85
View File
@@ -9,14 +9,17 @@ from pydantic import ValidationError
from akkudoktoreos.core.coreabc import get_measurement
from akkudoktoreos.core.dataabc import DataSequence
from akkudoktoreos.core.databaseabc import DatabaseTimestamp
from akkudoktoreos.measurement.measurement import (
MeasurementChannelSettings,
MeasurementCommonSettings,
MeasurementDataRecord,
)
from akkudoktoreos.measurement.quality import SampleQuality
from akkudoktoreos.utils.datetimeutil import (
compare_datetimes,
to_datetime,
to_duration,
)
@@ -187,6 +190,8 @@ class TestMeasurement:
config_eos.measurement.load_emr_keys = ["load0_mr", "load1_mr", "load2_mr", "load3_mr"]
measurement = get_measurement()
await measurement.delete_by_datetime(None, None)
# Warn-once state lives on the shared singleton; start each test fresh.
measurement._reported_warnings.clear()
record0 = MeasurementDataRecord(
date_time=datetime(2023, 1, 1, hour=0),
load0_mr=100,
@@ -255,109 +260,176 @@ class TestMeasurement:
with pytest.raises(ValueError, match="interval must be positive"):
measurement_eos._interval_count(start, end, duration(hours=0))
async def test_energy_from_meter_readings_valid_input(self, measurement_eos):
"""Test _energy_from_meter_readings with valid inputs and proper alignment of load data."""
key = "load0_mr"
start_datetime = to_datetime("2023-01-01T00:00:00")
end_datetime = to_datetime("2023-01-01T05:00:00")
interval = duration(hours=1)
load_array = await measurement_eos._energy_from_meter_readings(
key, start_datetime, end_datetime, interval
async def test_meter_energy_kwh_valid_input(self, measurement_eos):
"""Energy per interval is the difference of the readings at its boundaries."""
result = await measurement_eos.meter_energy_kwh(
["load0_mr", "load1_mr"],
to_datetime("2023-01-01T00:00:00"),
to_datetime("2023-01-01T05:00:00"),
to_duration("1 hour"),
)
expected_load_array = np.array([50, 50, 50, 50, 50]) # Differences between consecutive readings
np.testing.assert_array_equal(load_array, expected_load_array)
np.testing.assert_array_equal(result["load0_mr"], [50, 50, 50, 50, 50])
np.testing.assert_array_equal(result["load1_mr"], [50, 50, 50, 50, 50])
async def test_energy_from_meter_readings_empty_array(self, measurement_eos):
"""Test _energy_from_meter_readings with no data (empty array)."""
key = "load0_mr"
async def test_meter_energy_kwh_interpolates_a_missing_reading(self, measurement_eos):
"""A reading missing at an interval boundary is interpolated from its neighbours."""
start_datetime = to_datetime("2023-01-01T00:00:00")
end_datetime = to_datetime("2023-01-01T05:00:00")
interval = duration(hours=1)
# Use empyt records array
await measurement_eos.delete_by_datetime(start_datetime, end_datetime)
load_array = await measurement_eos._energy_from_meter_readings(
key, start_datetime, end_datetime, interval
)
# Expected: an array of zeros with one less than the number of intervals
expected_size = (
measurement_eos._interval_count(start_datetime, end_datetime + interval, interval) - 1
)
expected_load_array = np.zeros(expected_size)
np.testing.assert_array_equal(load_array, expected_load_array)
async def test_energy_from_meter_readings_misaligned_array(self, measurement_eos):
"""Test _energy_from_meter_readings with misaligned array size."""
key = "load1_mr"
interval = duration(hours=1)
start_datetime = to_datetime("2023-01-01T00:00:00")
end_datetime = to_datetime("2023-01-01T05:00:00")
# Use misaligned array, latest interval set to 2 hours (instead of 1 hour)
latest_record_datetime = to_datetime("2023-01-01T05:00:00")
new_record_datetime = to_datetime("2023-01-01T06:00:00")
record = await measurement_eos.get_by_datetime(latest_record_datetime)
record = await measurement_eos.get_by_datetime(to_datetime("2023-01-01T05:00:00"))
assert record is not None
await measurement_eos.delete_by_datetime(start_datetime = latest_record_datetime,
end_datetime = new_record_datetime)
record.date_time = new_record_datetime
await measurement_eos.delete_by_datetime(
start_datetime=to_datetime("2023-01-01T05:00:00"),
end_datetime=to_datetime("2023-01-01T06:00:00"),
)
record.date_time = to_datetime("2023-01-01T06:00:00")
record.load1_mr = 500
await measurement_eos.insert_by_datetime(record)
# Check test setup
dates, values = await measurement_eos.key_to_lists(key, start_datetime, None)
assert dates == [
to_datetime("2023-01-01T00:00:00"),
to_datetime("2023-01-01T01:00:00"),
to_datetime("2023-01-01T02:00:00"),
to_datetime("2023-01-01T03:00:00"),
to_datetime("2023-01-01T04:00:00"),
to_datetime("2023-01-01T06:00:00"),
]
assert values == [200, 250, 300, 350, 400, 450]
array = await measurement_eos.key_to_array(key, start_datetime, end_datetime + interval, interval=interval)
np.testing.assert_array_equal(array, [200, 250, 300, 350, 400, 425])
load_array = await measurement_eos._energy_from_meter_readings(
key, start_datetime, end_datetime, interval
result = await measurement_eos.meter_energy_kwh(
["load1_mr"], start_datetime, to_datetime("2023-01-01T06:00:00"), to_duration("1 hour")
)
expected_load_array = np.array([50., 50., 50., 50., 25.]) # Differences between consecutive readings
np.testing.assert_array_equal(load_array, expected_load_array)
np.testing.assert_array_equal(result["load1_mr"], [50.0, 50.0, 50.0, 50.0, 50.0, 50.0])
async def test_energy_from_meter_readings_partial_data(self, measurement_eos, caplog):
"""Test _energy_from_meter_readings with partial data (misaligned but empty array)."""
key = "load2_mr"
start_datetime = to_datetime("2023-01-01T00:00:00")
end_datetime = to_datetime("2023-01-01T05:00:00")
interval = duration(hours=1)
async def test_meter_energy_kwh_is_nan_outside_the_readings(self, measurement_eos):
"""Intervals before the first or after the last reading are unknown."""
result = await measurement_eos.meter_energy_kwh(
["load0_mr", "load2_mr"],
to_datetime("2022-12-31T23:00:00"),
to_datetime("2023-01-01T07:00:00"),
to_duration("1 hour"),
)
np.testing.assert_array_equal(
result["load0_mr"], [np.nan, 50, 50, 50, 50, 50, np.nan, np.nan]
)
assert np.isnan(result["load2_mr"]).all()
async def test_meter_energy_kwh_extends_a_partial_last_interval(self, measurement_eos):
"""A period that ends inside an interval still yields that full interval."""
result = await measurement_eos.meter_energy_kwh(
["load0_mr"],
to_datetime("2023-01-01T00:00:00"),
to_datetime("2023-01-01T02:20:00"),
to_duration("1 hour"),
)
np.testing.assert_array_equal(result["load0_mr"], [50, 50, 50])
async def test_meter_energy_kwh_negative_interval(self, measurement_eos):
"""A non-positive interval is rejected."""
with pytest.raises(ValueError, match="positive whole number of seconds"):
await measurement_eos.meter_energy_kwh(
["load0_mr"],
to_datetime("2023-01-01T00:00:00"),
to_datetime("2023-01-01T05:00:00"),
to_duration(-3600),
)
async def test_keys_first_and_last_datetime(self, measurement_eos):
"""First and last valid reading per key, each key on its own.
load1_mr reports two days longer than load0_mr, so the backward scan finds the
two last readings in different windows; a trailing non-finite value of
load0_mr is no reading.
"""
for hour in range(6, 54):
await measurement_eos.update_value(
to_datetime("2023-01-01T00:00:00").add(hours=hour), "load1_mr", 450 + hour
)
await measurement_eos.update_value(
to_datetime("2023-01-03T12:00:00"), "load0_mr", float("nan")
)
keys = ["load0_mr", "load1_mr", "load1_mr", "load2_mr"]
firsts = await measurement_eos.keys_first_datetime(keys)
lasts = await measurement_eos.keys_last_datetime(keys)
assert firsts == {
"load0_mr": to_datetime("2023-01-01T00:00:00"),
"load1_mr": to_datetime("2023-01-01T00:00:00"),
}
assert lasts == {
"load0_mr": to_datetime("2023-01-01T05:00:00"),
"load1_mr": to_datetime("2023-01-03T05:00:00"),
}
timezone = measurement_eos.config.general.timezone
assert all(stamp.timezone_name == timezone for stamp in [*firsts.values(), *lasts.values()])
async def test_conversion_failure_is_logged_once_per_streak(self, measurement_eos, caplog):
"""Error on the first failure, debug while it persists, error again after a success."""
def levels() -> set[str]:
levels = {r.levelname for r in caplog.records if "conversion failed" in r.getMessage()}
caplog.clear()
return levels
with caplog.at_level("DEBUG"):
load_array = await measurement_eos._energy_from_meter_readings(
key, start_datetime, end_datetime, interval
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
assert levels() == {"ERROR"}
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
assert levels() == {"DEBUG"}
# Each consumer has its own streak.
measurement_eos.report_conversion_failure("other", "other: conversion failed")
assert levels() == {"ERROR"}
measurement_eos.clear_conversion_failure("consumer")
measurement_eos.report_conversion_failure("consumer", "consumer: conversion failed")
assert levels() == {"ERROR"}
async def test_keys_valid_datetimes(self, measurement_eos):
"""Stamps of valid readings in [start, end): invalid quality does not count."""
stamp = to_datetime("2023-01-01T02:00:00")
record = await measurement_eos.db_get_record(DatabaseTimestamp.from_datetime(stamp))
record.sample_quality["load0_mr"] = SampleQuality(status="invalid")
await measurement_eos.db_mark_dirty_record(record)
stamps = await measurement_eos.keys_valid_datetimes(
["load0_mr", "load_silent_mr"],
to_datetime("2023-01-01T01:00:00"),
to_datetime("2023-01-01T04:00:00"),
)
expected_size = (
measurement_eos._interval_count(start_datetime, end_datetime + interval, interval) - 1
assert stamps == {
"load0_mr": [to_datetime("2023-01-01T01:00:00"), to_datetime("2023-01-01T03:00:00")],
"load_silent_mr": [],
}
async def test_load_total_kwh_warns_once_about_a_silent_meter(self, measurement_eos, caplog):
"""A configured meter that never reports is a warning once, not on every run."""
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load_silent_mr"]
period = {
"start_datetime": to_datetime("2023-01-01T00:00:00"),
"end_datetime": to_datetime("2023-01-01T03:00:00"),
"interval": to_duration("1 hour"),
}
def silent_meter_warnings() -> int:
return sum(
record.levelname == "WARNING"
and "'load_silent_mr' gives no usable energy" in record.getMessage()
for record in caplog.records
)
expected_load_array = np.zeros(expected_size)
np.testing.assert_array_equal(load_array, expected_load_array)
async def test_energy_from_meter_readings_negative_interval(self, measurement_eos):
"""Test _energy_from_meter_readings with a negative interval."""
key = "load3_mr"
start_datetime = to_datetime("2023-01-01T00:00:00")
end_datetime = to_datetime("2023-01-01T05:00:00")
interval = duration(hours=-1)
with caplog.at_level("WARNING"):
await measurement_eos.load_total_kwh(**period)
first_run = silent_meter_warnings()
await measurement_eos.load_total_kwh(**period)
with pytest.raises(ValueError, match="interval must be positive"):
await measurement_eos._energy_from_meter_readings(key, start_datetime, end_datetime, interval)
assert first_run > 0
assert silent_meter_warnings() == first_run
async def test_load_total_kwh_empty_store_without_period(self, measurement_eos):
"""No data and no period yields an empty result, not an error."""
await measurement_eos.delete_by_datetime(None, None)
result = await measurement_eos.load_total_kwh()
assert result.shape == (0,)
async def test_load_total_kwh(self, measurement_eos):
"""Test total load calculation."""
# Only these meters report; a silent configured meter makes the total unknown.
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
start_datetime = to_datetime("2023-01-01T03:00:00")
end_datetime = to_datetime("2023-01-01T05:00:00")
interval = duration(hours=1)
@@ -376,11 +448,13 @@ class TestMeasurement:
interval = duration(hours=1)
result = await measurement_eos.load_total_kwh(start_datetime=start_datetime, end_datetime=end_datetime, interval=interval)
expected = np.zeros(3) # No data, so all intervals are zero
np.testing.assert_array_equal(result, expected)
# No data: the load of every interval is unknown, not zero.
assert result.shape == (3,)
assert np.isnan(result).all()
async def test_load_total_kwh_partial_intervals(self, measurement_eos):
"""Test total load calculation with partial intervals."""
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
start_datetime = to_datetime("2023-01-01T00:30:00") # Start in the middle of an interval
end_datetime = to_datetime("2023-01-01T01:30:00") # End in the middle of another interval
interval = duration(hours=1)
@@ -390,6 +464,60 @@ class TestMeasurement:
np.testing.assert_array_equal(result, expected)
async def test_load_total_kwh_follows_a_jittered_meter(self, measurement_eos):
"""Hourly load energy is exact for a meter reporting at arbitrary stamps.
The meter reports every ~5 minutes off the hour. Load is 1 kW until noon and
3 kW afterwards; each hour must get exactly its own energy, also around the step.
"""
measurement_eos.config.measurement.load_emr_keys = ["load_jitter_mr"]
start = to_datetime("2023-02-01T00:00:00Z")
jitter = [0, 21, 47, 13, 34]
stamp = to_datetime("2023-01-31T23:57:10Z")
energy_kwh = 0.0
step = 0
while compare_datetimes(stamp, to_datetime("2023-02-02T00:15:00Z")).lt:
await measurement_eos.update_value(stamp, "load_jitter_mr", round(energy_kwh, 6))
following = stamp.add(minutes=5, seconds=jitter[step % len(jitter)])
noon = to_datetime("2023-02-01T12:00:00Z")
seconds_before_noon = max(0.0, min(following.timestamp(), noon.timestamp()) - stamp.timestamp())
seconds_after_noon = (following.timestamp() - stamp.timestamp()) - seconds_before_noon
energy_kwh += (1.0 * seconds_before_noon + 3.0 * seconds_after_noon) / 3600.0
stamp = following
step += 1
result = await measurement_eos.load_total_kwh(
start_datetime=start, end_datetime=start.add(days=1), interval=to_duration("1 hour")
)
# Away from the step every hour is exact. The step lies inside one ~5-minute
# reading interval, which a meter cannot resolve: hours 11 and 12 share it, but
# keep their sum (a bucket-mean conversion moves about half an hour across).
np.testing.assert_allclose(result[:11], 1.0, atol=1e-5)
np.testing.assert_allclose(result[13:], 3.0, atol=1e-5)
assert result[11] == pytest.approx(1.0, abs=0.05)
assert result[12] == pytest.approx(3.0, abs=0.05)
assert result[11] + result[12] == pytest.approx(4.0, abs=1e-5)
async def test_load_total_kwh_is_nan_without_full_coverage(self, measurement_eos):
"""An hour a load meter does not fully cover is unknown, not zero load."""
result = await measurement_eos.load_total_kwh(
start_datetime=to_datetime("2023-01-01T03:00:00"),
end_datetime=to_datetime("2023-01-01T07:00:00"),
interval=to_duration("1 hour"),
)
# load2_mr and load3_mr are configured but never report.
assert np.isnan(result).all()
measurement_eos.config.measurement.load_emr_keys = ["load0_mr", "load1_mr"]
result = await measurement_eos.load_total_kwh(
start_datetime=to_datetime("2023-01-01T03:00:00"),
end_datetime=to_datetime("2023-01-01T07:00:00"),
interval=to_duration("1 hour"),
)
np.testing.assert_array_equal(result, [100.0, 100.0, np.nan, np.nan])
class TestMeasurementFileRestore:
@pytest.fixture
def file_measurements(self, config_eos, tmp_path, monkeypatch):
@@ -546,3 +674,62 @@ class TestMeasurementChannels:
measurement.records = previous_records
config_eos.measurement = previous_settings
config_eos.general.data_folder_path = previous_folder
@pytest.mark.asyncio
class TestMeasurementCommonPeriod:
"""Common period of a meter group and its warnings."""
@pytest_asyncio.fixture
async def measurement(self, config_eos):
# Configured meter keys are writable record keys of the store.
config_eos.measurement.load_emr_keys = ["meter_a_mr", "meter_b_mr"]
measurement = get_measurement()
await measurement.delete_by_datetime(None, None)
measurement._reported_warnings.clear()
yield measurement
await measurement.delete_by_datetime(None, None)
measurement._reported_warnings.clear()
@staticmethod
def warnings(caplog, text: str) -> int:
return sum(
record.levelname == "WARNING" and text in record.getMessage()
for record in caplog.records
)
async def test_silent_group_is_warned_again_after_it_reported(self, measurement, caplog):
keys = ["meter_a_mr", "meter_b_mr"]
start = to_datetime("2024-01-01T00:00:00Z")
with caplog.at_level("WARNING"):
assert await measurement.keys_common_period(keys, "test") is None
first = self.warnings(caplog, "have no valid readings")
for hour in range(3):
for key in keys:
await measurement.update_value(start.add(hours=hour), key, 10.0 + hour)
assert await measurement.keys_common_period(keys, "test") is not None
await measurement.delete_by_datetime(None, None)
assert await measurement.keys_common_period(keys, "test") is None
assert first > 0
assert self.warnings(caplog, "have no valid readings") > first
async def test_single_reading_is_no_replaced_meter(self, measurement, caplog):
await measurement.update_value(to_datetime("2024-01-01T00:00:00Z"), "meter_a_mr", 10.0)
with caplog.at_level("WARNING"):
assert await measurement.keys_common_period(["meter_a_mr"], "test") is None
assert self.warnings(caplog, "share no period") == 0
async def test_touching_replacement_is_a_replaced_meter(self, measurement, caplog):
"""A swap where the new meter starts at the old meter's last stamp is named."""
start = to_datetime("2024-01-01T00:00:00Z")
for hour in range(4):
await measurement.update_value(start.add(hours=hour), "meter_a_mr", 10.0 + hour)
await measurement.update_value(start.add(hours=3 + hour), "meter_b_mr", 50.0 + hour)
with caplog.at_level("WARNING"):
assert await measurement.keys_common_period(["meter_a_mr", "meter_b_mr"], "test") is None
assert self.warnings(caplog, "meter 'meter_a_mr' last reported at") > 0
+21 -1
View File
@@ -8,8 +8,9 @@ from zoneinfo import ZoneInfo
import pytest
from akkudoktoreos.measurement.energy import energy_intervals
from akkudoktoreos.measurement.energy import energy_intervals, valid_reading
from akkudoktoreos.measurement.measurement import MeasurementChannelSettings
from akkudoktoreos.measurement.quality import SampleQuality
from akkudoktoreos.utils.datetimeutil import to_datetime
START = datetime(2026, 9, 10, tzinfo=timezone.utc)
@@ -133,3 +134,22 @@ async def test_measurement_wrapper_preserves_asynchronous_channels(config_eos):
measurement._db_reset_state()
measurement.records = records
config_eos.measurement = previous
@pytest.mark.parametrize(
("value", "quality", "expected"),
[
(1, None, 1.0),
(2.5, SampleQuality(status="estimated"), 2.5),
(2.5, SampleQuality(status="invalid"), None),
(2.5, SampleQuality(status="unavailable"), None),
(True, None, None),
(float("nan"), None, None),
(float("inf"), None, None),
(None, None, None),
("1.0", None, None),
],
)
def test_valid_reading(value: Any, quality: SampleQuality | None, expected: float | None) -> None:
"""One rule decides which raw readings count, shared by conversion and scans."""
assert valid_reading(value, quality) == expected
+100
View File
@@ -12,6 +12,7 @@ import pytest_asyncio
import requests
from akkudoktoreos.core.coreabc import get_ems, get_measurement, get_prediction
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor
from akkudoktoreos.prediction.pvforecastakkudoktorlocal import (
PVForecastAkkudoktorLocal,
@@ -103,6 +104,8 @@ async def pvforecast_instance(config_eos):
get_ems().set_start_datetime(START)
await provider.delete_by_datetime()
await get_measurement().delete_by_datetime()
# Warn-once state lives on the shared singleton; start each test fresh.
get_measurement()._reported_warnings.clear()
yield provider
await provider.delete_by_datetime()
await get_measurement().delete_by_datetime()
@@ -404,6 +407,30 @@ async def test_calibration_uses_real_quarter_hour_measurements(pvforecast_instan
assert "15-minute measurement resolution" in caplog.text or "15-minute intervals" in caplog.text
@pytest.mark.asyncio
async def test_meter_resolution_counts_valid_readings_only(pvforecast_instance):
"""Invalid intrahour readings must not make an hourly meter look quarter-hourly.
Fitting native slots on such a meter would interpolate within each hour and
invent a flat intrahour profile.
"""
key = "pv_hourly_valid_emr"
pvforecast_instance.config.measurement.pv_production_emr_keys = [key]
start = START.subtract(days=3)
samples = []
for slot in range(3 * 24 * 4):
stamp = start.add(minutes=15 * slot)
quality = (
SampleQuality(status="measured") if slot % 4 == 0 else SampleQuality(status="invalid")
)
samples.append(
MeasurementSample(date_time=stamp, key=key, value=float(slot), quality=quality)
)
await get_measurement().import_samples(samples)
assert await pvforecast_instance._calibration_interval_minutes(start, START) == 60
@pytest.mark.asyncio
async def test_calibration_factor_is_clamped(pvforecast_instance):
"""A wildly wrong meter must not be allowed to swing the forecast."""
@@ -1059,3 +1086,76 @@ async def test_snow_feedback_window_is_on_the_slot_grid(pvforecast_instance, rec
assert end.timestamp() % 900 == 0
assert compare_datetimes(end, pv_window.last).le
assert compare_datetimes(end.add(minutes=15), pv_window.last).gt
@pytest.mark.asyncio
async def test_calibration_falls_back_when_the_meter_conversion_fails(
pvforecast_instance, monkeypatch, caplog
):
"""A broken PV meter history disables calibration instead of the forecast."""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(snow_enabled=True)
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
await _feed_meters(pvforecast_instance, {"pv_broken_emr": meter})
async def failing_production_total_kwh(self, start_datetime, end_datetime, interval):
raise ValueError("Overlapping source energy intervals.")
monkeypatch.setattr(
PVForecastAkkudoktorLocal, "_pv_production_total_kwh", failing_production_total_kwh
)
with caplog.at_level("ERROR"):
forecast = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
calibration = await _fit(pvforecast_instance, frame)
assert calibration is None
np.testing.assert_allclose(forecast["ac_power"], frame["ac_power"])
assert "calibration: PV meter energy conversion failed" in caplog.text
@pytest.mark.asyncio
async def test_calibration_warns_about_a_stale_common_meter_period(pvforecast_instance, caplog):
"""A PV meter that stopped reporting holds the fit on old data - say so."""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
await _feed_meters(pvforecast_instance, {"pv_stale_emr": meter})
def stale_warnings() -> int:
return sum(
record.levelname == "WARNING"
and "meter 'pv_stale_emr' last reported at" in record.getMessage()
for record in caplog.records
)
with caplog.at_level("WARNING"):
get_ems().set_start_datetime(START.add(hours=12))
await _fit(pvforecast_instance, frame)
fresh = stale_warnings()
get_ems().set_start_datetime(START.add(days=3))
calibration = await _fit(pvforecast_instance, frame)
first_stale_run = stale_warnings()
await _fit(pvforecast_instance, frame)
_assert_fitted_bias(calibration, 0.8)
assert fresh == 0
assert first_stale_run > 0
# Once per stale period, not on every run.
assert stale_warnings() == first_stale_run
@pytest.mark.asyncio
async def test_pv_meter_window_skips_readings_that_vanish_between_scans(
pvforecast_instance, monkeypatch
):
"""Readings removed between the first and last scan give no window, not an error."""
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
await _feed_meters(pvforecast_instance, {"pv_vanishing_emr": meter})
monkeypatch.setattr(
type(get_measurement()), "keys_last_datetime", AsyncMock(return_value={})
)
assert await pvforecast_instance._pv_measurement_window() is None
+32 -2
View File
@@ -390,9 +390,39 @@ async def test_stale_meter_readings_are_reported(snow_instance, caplog):
await feed_meter("stale", fixture, local("2026-02-20 09:00"))
get_ems().set_start_datetime(local("2026-02-20 15:00"))
await snow_instance._forecast_frame(fixture["openmeteo"])
def stale_levels() -> set[str]:
return {
record.levelname for record in caplog.records if "older than 3 h" in record.getMessage()
}
assert "older than 3 h" in caplog.text
with caplog.at_level("DEBUG"):
await snow_instance._forecast_frame(fixture["openmeteo"])
assert stale_levels() == {"WARNING"}
caplog.clear()
# Reported once per stale reading, not on every forecast run.
await snow_instance._forecast_frame(fixture["openmeteo"])
assert stale_levels() == {"DEBUG"}
@pytest.mark.asyncio
async def test_missing_meter_period_is_warned_once(snow_instance, caplog):
"""Without a PV meter period only the meter lookup warns, once, not snow feedback."""
fixture = load_fixture()
get_measurement()._reported_warnings.clear()
snow_instance.config.measurement.pv_production_emr_keys = ["silent"]
get_ems().set_start_datetime(local("2026-02-20 15:00"))
def warnings() -> set[str]:
return {r.getMessage() for r in caplog.records if r.levelname == "WARNING"}
with caplog.at_level("DEBUG"):
await snow_instance._forecast_frame(fixture["openmeteo"])
(message,) = warnings()
assert "'silent'" in message and "no valid readings" in message
caplog.clear()
# The lasting condition is not warned about again on the next forecast run.
await snow_instance._forecast_frame(fixture["openmeteo"])
assert warnings() == set()
# ---------------------------------------------------------------- calibration