feat(devices): add inverter profiles
An inverter profile describes the technical data of an inverter model: its nominal AC power, the DC→AC and AC→DC efficiency curves over the load fraction (AC power relative to the nominal power), the AC charge power limit of the model, whether that limit also limits PV charging, and an optional power derating over the ambient temperature. Curves are read linearly and clamped at their ends, so every lookup yields a value. The packaged profile generic-hybrid has typical hybrid inverter efficiencies, no nominal power (the inverter device has to provide it) and full power up to 45 degC. Inverter settings name their profile (inverter_profile, default generic-hybrid) and hold the differences of the unit in profile_adjustment: nominal_power_w (replaces the profile value, required for a generic profile), max_power_w and max_ac_charge_power_w (installation limits that can only lower; an AC charge limit of 0 disables AC charging). The effective parameters are resolved at the ambient temperature of the inverter, given by the new measurement key <device_id>-temperature-degc (45 degC without a fresh value); the power derating lowers the maximum power and the AC charge limit. Optimization parameters are always valid: the GENETIC and GENETIC0 parameter preparation resolve the inverter with resolve_current_operating_parameters_or_defaults, which never raises. An unusable profile gives the generic-hybrid profile, a missing nominal power the fallback of 10000 W, an inverter derated to zero power the parameters at 45 degC, and no usable profile at all the profile adjustment with constant efficiency; each is logged as error. The GENETIC inverter takes the AC→DC efficiency curve of the profile, solved exactly on each linear piece of the curve (about 2 % longer runs); GENETIC0 keeps constant efficiencies and no longer replaces the configured inverters with the demo inverter; a battery, electric vehicle or inverter that cannot be prepared is left out of the GENETIC0 run, never replaced by a demo device. Configurations migrate: max_power_w becomes profile_adjustment.nominal_power_w, max_ac_charge_power_w moves into the adjustment, an ac_to_dc_efficiency of 0 keeps AC charging disabled, and the efficiency fields are dropped with an error log, as for batteries, so the profile efficiencies apply. Home Assistant config paths follow. Additional changes - Move the curve algorithms of the battery profile into profilecurve, so battery and inverter profiles share them; the battery profile keeps its document format and classes. - Move ProfileBaseModel, the strict base of profile documents, into profilestore. - Serve inverter profiles through the profile REST API. Refuse to delete a profile that a configured device uses and that has no packaged profile to revert to (409). - Share the measurement access of the device settings in devicemeasurement. - Rename check_battery_profiles to check_device_profiles; the device profile check at configuration setup covers inverters, too. - Document inverter profiles, their configuration, defaults and sharing; regenerate the configuration and OpenAPI documentation. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
co-authored by
Claude Opus 5.5
parent
e255f987bf
commit
faf37abfe7
@@ -282,62 +282,68 @@ that is configured, even if more devices are configured.
|
||||
{
|
||||
"devices": {
|
||||
"max_inverters": 1,
|
||||
"inverters": [
|
||||
{
|
||||
"device_id": "inv1",
|
||||
"max_power_w": 10000,
|
||||
"battery_id": "bat1",
|
||||
"ac_to_dc_efficiency": 0.95,
|
||||
"dc_to_ac_efficiency": 0.95,
|
||||
"max_ac_charge_power_w": 5000
|
||||
}
|
||||
]
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
The inverter supports separate AC↔DC conversion efficiencies:
|
||||
|
||||
- `ac_to_dc_efficiency`: Conversion loss when charging the battery from AC grid power (0-1).
|
||||
Set to `0` to disable AC charging. Default `1.0`.
|
||||
- `dc_to_ac_efficiency`: Conversion loss when discharging battery to AC load/grid (0-1).
|
||||
Must be > 0. Default `1.0`.
|
||||
- `max_ac_charge_power_w`: Maximum AC charging power in watts. `null` = no additional limit.
|
||||
Set to `0` to disable AC charging. Default `null`.
|
||||
- `dc_to_ac_efficiency_curve`: Optional load-dependent DC→AC efficiency as a list of
|
||||
`[load_fraction, efficiency]` points, with the load fraction relative to `max_power_w`.
|
||||
Real inverters are much less efficient at low load, e.g. when the battery serves a small
|
||||
night-time base load. The points must be strictly increasing in load fraction (0-1) with
|
||||
efficiencies in (0, 1]; values in between are interpolated linearly, values outside are
|
||||
clamped to the first/last point. When set, the curve replaces `dc_to_ac_efficiency` for
|
||||
battery discharge. The efficiency is always the one at the AC power that is delivered: if
|
||||
the battery limits a discharge (low state of charge or its power limit), the conversion is
|
||||
evaluated at that lower load, not at the requested one. Default `null` (constant
|
||||
`dc_to_ac_efficiency`, unchanged behaviour).
|
||||
- `dc_to_ac_efficiency_reference_load_fraction`: Load fraction at which the curve is evaluated
|
||||
where stored energy is valued without a specific discharge, e.g. the energy left in the
|
||||
battery at the end of the horizon and the AC charge break-even. Choose the typical load
|
||||
the battery serves. Only used with `dc_to_ac_efficiency_curve`. Default `0.06`.
|
||||
|
||||
**Example with an efficiency curve:**
|
||||
|
||||
```json
|
||||
{
|
||||
"devices": {
|
||||
"inverters": {
|
||||
"inv1": {
|
||||
"max_power_w": 10000,
|
||||
"battery_id": "bat1",
|
||||
"dc_to_ac_efficiency_curve": [
|
||||
[0.02, 0.80], [0.07, 0.93], [0.30, 0.96], [1.00, 0.95]
|
||||
],
|
||||
"dc_to_ac_efficiency_reference_load_fraction": 0.06
|
||||
"inverter_profile": "generic-hybrid",
|
||||
"profile_adjustment": {
|
||||
"nominal_power_w": 10000,
|
||||
"max_ac_charge_power_w": 5000
|
||||
},
|
||||
"battery_id": "bat1"
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
The technical data of the inverter comes from an **inverter profile** (see
|
||||
[](#inverter-profiles)): the efficiency curves for battery discharge (DC→AC) and for charging
|
||||
the battery from the grid (AC→DC), the AC charge power limit of the model and the power derating
|
||||
over the ambient temperature. The inverter settings select the profile and describe how the unit
|
||||
differs from it:
|
||||
|
||||
- `inverter_profile`: Name of the inverter profile. Default `generic-hybrid`.
|
||||
- `profile_adjustment.nominal_power_w`: Nominal AC power of the installed inverter [W]. Replaces
|
||||
the nominal power of the profile; required for a generic profile such as `generic-hybrid`.
|
||||
- `profile_adjustment.max_power_w`: AC power limit of the installation [W], e.g. a configured
|
||||
output limit. Can only lower the (derated) nominal power. Default `null`.
|
||||
- `profile_adjustment.max_ac_charge_power_w`: AC charge power limit of the installation [W]. Can
|
||||
only lower the limit of the profile. Set to `0` to disable AC charging. Default `null`.
|
||||
- `dc_to_ac_efficiency_reference_load_fraction`: Load fraction of the maximum power at which the
|
||||
DC→AC efficiency curve is evaluated where stored energy is valued without a specific discharge,
|
||||
e.g. the energy left in the battery at the end of the horizon and the AC charge break-even.
|
||||
Choose the typical load the battery serves. Default `0.06`.
|
||||
|
||||
The efficiency curves are over the load fraction, the AC power relative to the nominal power.
|
||||
Real inverters are much less efficient at low load, e.g. when the battery serves a small
|
||||
night-time base load. The efficiency is always the one at the AC power of the conversion: if the
|
||||
battery limits a discharge (low state of charge or its power limit), the conversion is evaluated
|
||||
at that lower load, not at the requested one; charging from the grid draws the AC energy at the
|
||||
efficiency of the AC load actually drawn.
|
||||
|
||||
**Power derating:** inverters reduce their power when they get hot. EOS reads the ambient
|
||||
temperature of the inverter from the measurement `<device_id>-temperature-degc` (e.g.
|
||||
`inv1-temperature-degc`) at the start of each optimization and limits the maximum power and the
|
||||
AC charge power by the derating of the profile at that temperature. Without a measurement in the
|
||||
last hour EOS assumes 45 °C, where the `generic-hybrid` profile is not derated yet.
|
||||
|
||||
The resolved values are shown as read-only fields of the inverter configuration
|
||||
(`effective_nominal_power_w`, `effective_max_power_w`, `effective_max_ac_charge_power_w`,
|
||||
`effective_dc_to_ac_efficiency`, `effective_ac_to_dc_efficiency`), evaluated at 45 °C. If the
|
||||
configured inverter profile does not exist or is invalid, the optimization uses `generic-hybrid`
|
||||
with the profile adjustment instead and logs an error naming the inverter.
|
||||
|
||||
:::{admonition} Note
|
||||
:class: note
|
||||
Configurations of earlier versions are migrated automatically. `max_power_w` becomes
|
||||
`profile_adjustment.nominal_power_w` and `max_ac_charge_power_w` moves into the profile
|
||||
adjustment; an `ac_to_dc_efficiency` of `0` keeps AC charging disabled. The former fields
|
||||
`ac_to_dc_efficiency`, `dc_to_ac_efficiency`, `dc_to_ac_efficiency_curve` and
|
||||
`ac_charge_limits_total_charge` come from the inverter profile now and are dropped (logged as
|
||||
error), so the efficiencies of the profile apply instead of the former default `1.0` (lossless).
|
||||
To keep other values, save an own inverter profile and select it.
|
||||
:::
|
||||
|
||||