feat(devices): add inverter profiles

An inverter profile describes the technical data of an inverter model: its
nominal AC power, the DC→AC and AC→DC efficiency curves over the load
fraction (AC power relative to the nominal power), the AC charge power
limit of the model, whether that limit also limits PV charging, and an
optional power derating over the ambient temperature. Curves are read
linearly and clamped at their ends, so every lookup yields a value. The
packaged profile generic-hybrid has typical hybrid inverter efficiencies,
no nominal power (the inverter device has to provide it) and full power up
to 45 degC.

Inverter settings name their profile (inverter_profile, default
generic-hybrid) and hold the differences of the unit in profile_adjustment:
nominal_power_w (replaces the profile value, required for a generic
profile), max_power_w and max_ac_charge_power_w (installation limits that
can only lower; an AC charge limit of 0 disables AC charging). The
effective parameters are resolved at the ambient temperature of the
inverter, given by the new measurement key <device_id>-temperature-degc
(45 degC without a fresh value); the power derating lowers the maximum
power and the AC charge limit.

Optimization parameters are always valid: the GENETIC and GENETIC0
parameter preparation resolve the inverter with
resolve_current_operating_parameters_or_defaults, which never raises. An
unusable profile gives the generic-hybrid profile, a missing nominal power
the fallback of 10000 W, an inverter derated to zero power the parameters
at 45 degC, and no usable profile at all the profile adjustment with
constant efficiency; each is logged as error. The GENETIC inverter takes
the AC→DC efficiency curve of the profile, solved exactly on each linear
piece of the curve (about 2 % longer runs); GENETIC0 keeps constant
efficiencies and no longer replaces the configured inverters with the demo
inverter; a battery, electric vehicle or inverter that cannot be prepared
is left out of the GENETIC0 run, never replaced by a demo device.

Configurations migrate: max_power_w becomes
profile_adjustment.nominal_power_w, max_ac_charge_power_w moves into the
adjustment, an ac_to_dc_efficiency of 0 keeps AC charging disabled, and
the efficiency fields are dropped with an error log, as for batteries, so
the profile efficiencies apply. Home Assistant config paths follow.

Additional changes
- Move the curve algorithms of the battery profile into profilecurve, so
  battery and inverter profiles share them; the battery profile keeps its
  document format and classes.
- Move ProfileBaseModel, the strict base of profile documents, into
  profilestore.
- Serve inverter profiles through the profile REST API. Refuse to delete a
  profile that a configured device uses and that has no packaged profile
  to revert to (409).
- Share the measurement access of the device settings in
  devicemeasurement.
- Rename check_battery_profiles to check_device_profiles; the device
  profile check at configuration setup covers inverters, too.
- Document inverter profiles, their configuration, defaults and sharing;
  regenerate the configuration and OpenAPI documentation.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
Bobby Noelte
2026-11-11 22:08:18 +01:00
co-authored by Claude Opus 5.5
parent e255f987bf
commit faf37abfe7
45 changed files with 3235 additions and 784 deletions
@@ -219,7 +219,11 @@ class ConfigOptimizationRequest(
device = groups["inverters"][0]
if device.battery_id != (battery.device_id if battery else None):
raise ValueError("Inverter battery_id must match the configured battery.")
inverter = device.to_genetic_param()
# The derating of the inverter profile applies at the measured
# ambient temperature, 45 degC without a measurement.
inverter = device.to_genetic_param(
await device.resolve_current_operating_parameters_or_defaults(observation_time)
)
if inverter is None:
raise ValueError("Configure an inverter to model PV and grid energy flows.")
appliances = [device.to_genetic_param() for device in groups["home_appliances"]]
@@ -26,6 +26,7 @@ from akkudoktoreos.devices.devicesabc import (
BatteryOperationMode,
)
from akkudoktoreos.devices.genetic.battery import Battery
from akkudoktoreos.devices.genetic.inverter import InverterParameters
from akkudoktoreos.optimization.genetic.geneticdevices import GeneticParametersBaseModel
from akkudoktoreos.optimization.genetic.geneticparams import (
GeneticOptimizationParameters,
@@ -593,6 +594,26 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
# Fallback → safe idle
return BatteryOperationMode.IDLE, 1.0
def _inverter_parameters_list(
self, parameters: Optional[GeneticOptimizationParameters]
) -> list[InverterParameters]:
"""Return the inverter parameters the solution was computed with, as a list.
Without stored parameters, the first configured inverter is resolved from
its inverter profile. An inverter that cannot be resolved is treated as
no inverter; the configuration check already reported it.
"""
if parameters is not None:
return [parameters.inverter] if parameters.inverter is not None else []
inverters = self.config.devices.inverters or {}
if not inverters:
return []
try:
return [list(inverters.values())[0].to_genetic_param()]
except ValueError as exc:
logger.debug(f"Inverter not resolvable for the solution: {exc}")
return []
def _soc_clamped_operation_factors(
self,
ac_charge: float,
@@ -649,13 +670,7 @@ class GeneticSolution(ConfigMixin, GeneticParametersBaseModel):
if headroom_wh <= 0.0:
effective_ac = 0.0
else:
inv_list = (
[parameters.inverter]
if parameters is not None and parameters.inverter is not None
else list((self.config.devices.inverters or {}).values())
if parameters is None
else []
)
inv_list = self._inverter_parameters_list(parameters)
ac_to_dc_eff = float(inv_list[0].ac_to_dc_efficiency) if inv_list else 1.0
max_ac_cp_w = (
float(inv_list[0].max_ac_charge_power_w)
@@ -37,7 +37,6 @@ from akkudoktoreos.devices.genetic0.genetic0homeappliance import (
Genetic0HomeApplianceParameters,
)
from akkudoktoreos.devices.genetic0.genetic0inverter import Genetic0InverterParameters
from akkudoktoreos.devices.settings.batterysettings import BatteriesCommonSettings
from akkudoktoreos.optimization.genetic0.genetic0abc import Genetic0ParametersBaseModel
from akkudoktoreos.optimization.genetic.forecast import bounded_forecast_array
from akkudoktoreos.utils.datetimeutil import DateTime, to_duration
@@ -47,12 +46,15 @@ from akkudoktoreos.utils.datetimeutil import DateTime, to_duration
# StartMixin - Creates circular dependency with ems.py
# Demo devices: used if no device is configured, and for this run only if the
# configured device cannot be prepared.
# Demo devices: used if no device of a kind is configured.
DEMO_BATTERY_SETTINGS: dict = {
"device_id": "battery1",
"profile_adjustment": {"nominal_capacity_wh": 8000},
}
DEMO_INVERTER_SETTINGS: dict = {
"device_id": "inverter1",
"profile_adjustment": {"nominal_power_w": 10000},
}
DEMO_ELECTRIC_VEHICLE_SETTINGS: dict = {
"device_id": "ev1",
"profile_adjustment": {"nominal_capacity_wh": 50000},
@@ -603,47 +605,45 @@ class Genetic0OptimizationParameters(
) = await battery_config.resolve_current_operating_parameters_or_defaults()
battery_params = battery_config.to_genetic0_pv_bat_param(battery_parameters)
except Exception as e:
# Never cancel the run and never change the user's configuration:
# optimize with the demo battery for this run only.
# Never cancel the run, never change the user's configuration and
# never invent a device: optimize without this battery.
logger.error(
"Battery '{}' cannot be prepared for the optimization: {} "
"Using the demo battery for this run.",
"The battery is left out of this run.",
battery_config.device_id,
e,
)
battery_config = BatteriesCommonSettings(**DEMO_BATTERY_SETTINGS)
battery_parameters, _ = (
battery_config.resolve_operating_parameters_or_defaults()
)
battery_params = battery_config.to_genetic0_pv_bat_param(battery_parameters)
# Levelized cost of ownership
if battery_config.levelized_cost_of_storage_amt_kwh is None:
logger.info(
"No battery device LCOS data available - defaulting to 0 [amount/kWh]. Parameter preparation attempt {}.",
attempt,
)
battery_config.levelized_cost_of_storage_amt_kwh = 0
battery_lcos_kwh = battery_config.levelized_cost_of_storage_amt_kwh
# Initial SOC
try:
initial_soc_factor = await cls._nearest_soc_factor(
battery_config.measurement_key_soc_factor, ems.observation_datetime
)
if initial_soc_factor > 1.0 or initial_soc_factor < 0.0:
logger.error(
f"Invalid battery initial SoC factor {initial_soc_factor} - defaulting to 0.0."
battery_params = None
battery_lcos_kwh = 0
if battery_params is not None:
# Levelized cost of ownership
if battery_config.levelized_cost_of_storage_amt_kwh is None:
logger.info(
"No battery device LCOS data available - defaulting to 0 [amount/kWh]. Parameter preparation attempt {}.",
attempt,
)
initial_soc_factor = 0.0
# genetic parameter is 0..100 as int
initial_soc_percentage = int(initial_soc_factor * 100)
except Exception:
initial_soc_percentage = None
if initial_soc_percentage is None:
logger.info(
f"No battery device SoC data (measurement key = '{battery_config.measurement_key_soc_factor}') available - defaulting to 0."
)
initial_soc_percentage = 0
battery_params.initial_soc_percentage = initial_soc_percentage
battery_config.levelized_cost_of_storage_amt_kwh = 0
battery_lcos_kwh = battery_config.levelized_cost_of_storage_amt_kwh
# Initial SOC
try:
initial_soc_factor = await cls._nearest_soc_factor(
battery_config.measurement_key_soc_factor, ems.observation_datetime
)
if initial_soc_factor > 1.0 or initial_soc_factor < 0.0:
logger.error(
f"Invalid battery initial SoC factor {initial_soc_factor} - defaulting to 0.0."
)
initial_soc_factor = 0.0
# genetic parameter is 0..100 as int
initial_soc_percentage = int(initial_soc_factor * 100)
except Exception:
initial_soc_percentage = None
if initial_soc_percentage is None:
logger.info(
f"No battery device SoC data (measurement key = '{battery_config.measurement_key_soc_factor}') available - defaulting to 0."
)
initial_soc_percentage = 0
battery_params.initial_soc_percentage = initial_soc_percentage
# Electric Vehicles
# -----------------
@@ -673,44 +673,37 @@ class Genetic0OptimizationParameters(
ev_parameters
)
except Exception as e:
# Never cancel the run and never change the user's configuration:
# optimize with the demo electric vehicle for this run only.
# Never cancel the run, never change the user's configuration and
# never invent a device: optimize without this electric vehicle.
logger.error(
"Electric vehicle '{}' cannot be prepared for the optimization: {} "
"Using the demo electric vehicle for this run.",
"The electric vehicle is left out of this run.",
electric_vehicle_config.device_id,
e,
)
electric_vehicle_config = BatteriesCommonSettings(
**DEMO_ELECTRIC_VEHICLE_SETTINGS
)
(
ev_parameters,
_,
) = electric_vehicle_config.resolve_operating_parameters_or_defaults()
electric_vehicle_params = electric_vehicle_config.to_genetic0_ev_bat_param(
ev_parameters
)
# Initial SOC
try:
initial_soc_factor = await cls._nearest_soc_factor(
electric_vehicle_config.measurement_key_soc_factor, ems.observation_datetime
)
if initial_soc_factor > 1.0 or initial_soc_factor < 0.0:
logger.error(
f"Invalid electric vehicle initial SoC factor {initial_soc_factor} - defaulting to 0.0."
electric_vehicle_params = None
if electric_vehicle_params is not None:
# Initial SOC
try:
initial_soc_factor = await cls._nearest_soc_factor(
electric_vehicle_config.measurement_key_soc_factor,
ems.observation_datetime,
)
initial_soc_factor = 0.0
# genetic parameter is 0..100 as int
initial_soc_percentage = int(initial_soc_factor * 100)
except Exception:
initial_soc_percentage = None
if initial_soc_percentage is None:
logger.info(
f"No electric vehicle device SoC data (measurement key = '{electric_vehicle_config.measurement_key_soc_factor}') available - defaulting to 0."
)
initial_soc_percentage = 0
electric_vehicle_params.initial_soc_percentage = initial_soc_percentage
if initial_soc_factor > 1.0 or initial_soc_factor < 0.0:
logger.error(
f"Invalid electric vehicle initial SoC factor {initial_soc_factor} - defaulting to 0.0."
)
initial_soc_factor = 0.0
# genetic parameter is 0..100 as int
initial_soc_percentage = int(initial_soc_factor * 100)
except Exception:
initial_soc_percentage = None
if initial_soc_percentage is None:
logger.info(
f"No electric vehicle device SoC data (measurement key = '{electric_vehicle_config.measurement_key_soc_factor}') available - defaulting to 0."
)
initial_soc_percentage = 0
electric_vehicle_params.initial_soc_percentage = initial_soc_percentage
# Inverters
# ---------
@@ -724,30 +717,27 @@ class Genetic0OptimizationParameters(
logger.info("No inverter device data available - defaulting to demo data.")
cls.config.devices.inverters = {
"inverter1": {
"device_id": "inverter1",
"max_power_w": 10000,
**DEMO_INVERTER_SETTINGS,
"battery_id": battery_config.device_id,
},
}
# Take first inverter
inverter_config = list(cls.config.devices.inverters.values())[0]
try:
# Take first inverter
inverter_config = list(cls.config.devices.inverters.values())[0]
inverter_params = inverter_config.to_genetic0_param()
# A configuration error gives default values, reported as error.
inverter_params = inverter_config.to_genetic0_param(
await inverter_config.resolve_current_operating_parameters_or_defaults()
)
except Exception as e:
logger.info(
"No inverter device data available - defaulting to demo data. Parameter preparation attempt {}: {}",
attempt,
# Never cancel the run, never change the user's configuration and
# never invent a device: optimize without this inverter.
logger.error(
"Inverter '{}' cannot be prepared for the optimization: {} "
"The inverter is left out of this run.",
inverter_config.device_id,
e,
)
cls.config.devices.inverters = {
"inverter1": {
"device_id": "inverter1",
"max_power_w": 10000,
"battery_id": battery_config.device_id,
},
}
# Retry
continue
inverter_params = None
# Home Appliances
# ---------------
@@ -26,6 +26,7 @@ from akkudoktoreos.devices.devicesabc import (
BatteryOperationMode,
)
from akkudoktoreos.devices.genetic0.genetic0battery import Genetic0Battery
from akkudoktoreos.devices.genetic0.genetic0inverter import Genetic0InverterParameters
from akkudoktoreos.optimization.genetic0.genetic0devices import (
Genetic0ParametersBaseModel,
)
@@ -507,6 +508,26 @@ class Genetic0Solution(ConfigMixin, Genetic0ParametersBaseModel):
# Fallback → safe idle
return BatteryOperationMode.IDLE, 1.0
def _inverter_parameters(
self, parameters: Optional[Genetic0OptimizationParameters]
) -> Optional[Genetic0InverterParameters]:
"""Return the inverter parameters the solution was computed with.
Without stored parameters, the first configured inverter is resolved from
its inverter profile. An inverter that cannot be resolved is treated as
no inverter; the configuration check already reported it.
"""
if parameters is not None:
return parameters.inverter
inverters = self.config.devices.inverters or {}
if not inverters:
return None
try:
return list(inverters.values())[0].to_genetic0_param()
except ValueError as exc:
logger.debug(f"Inverter not resolvable for the solution: {exc}")
return None
def _soc_clamped_operation_factors(
self,
ac_charge: float,
@@ -565,8 +586,7 @@ class Genetic0Solution(ConfigMixin, Genetic0ParametersBaseModel):
if headroom_wh <= 0.0:
effective_ac = 0.0
else:
inv_dict = self.config.devices.inverters
inv = list(inv_dict.values())[0] if inv_dict else None
inv = self._inverter_parameters(parameters)
ac_to_dc_eff = float(inv.ac_to_dc_efficiency) if inv else 1.0
max_ac_cp_w = (
float(inv.max_ac_charge_power_w)