feat(devices): add inverter profiles

An inverter profile describes the technical data of an inverter model: its
nominal AC power, the DC→AC and AC→DC efficiency curves over the load
fraction (AC power relative to the nominal power), the AC charge power
limit of the model, whether that limit also limits PV charging, and an
optional power derating over the ambient temperature. Curves are read
linearly and clamped at their ends, so every lookup yields a value. The
packaged profile generic-hybrid has typical hybrid inverter efficiencies,
no nominal power (the inverter device has to provide it) and full power up
to 45 degC.

Inverter settings name their profile (inverter_profile, default
generic-hybrid) and hold the differences of the unit in profile_adjustment:
nominal_power_w (replaces the profile value, required for a generic
profile), max_power_w and max_ac_charge_power_w (installation limits that
can only lower; an AC charge limit of 0 disables AC charging). The
effective parameters are resolved at the ambient temperature of the
inverter, given by the new measurement key <device_id>-temperature-degc
(45 degC without a fresh value); the power derating lowers the maximum
power and the AC charge limit.

Optimization parameters are always valid: the GENETIC and GENETIC0
parameter preparation resolve the inverter with
resolve_current_operating_parameters_or_defaults, which never raises. An
unusable profile gives the generic-hybrid profile, a missing nominal power
the fallback of 10000 W, an inverter derated to zero power the parameters
at 45 degC, and no usable profile at all the profile adjustment with
constant efficiency; each is logged as error. The GENETIC inverter takes
the AC→DC efficiency curve of the profile, solved exactly on each linear
piece of the curve (about 2 % longer runs); GENETIC0 keeps constant
efficiencies and no longer replaces the configured inverters with the demo
inverter; a battery, electric vehicle or inverter that cannot be prepared
is left out of the GENETIC0 run, never replaced by a demo device.

Configurations migrate: max_power_w becomes
profile_adjustment.nominal_power_w, max_ac_charge_power_w moves into the
adjustment, an ac_to_dc_efficiency of 0 keeps AC charging disabled, and
the efficiency fields are dropped with an error log, as for batteries, so
the profile efficiencies apply. Home Assistant config paths follow.

Additional changes
- Move the curve algorithms of the battery profile into profilecurve, so
  battery and inverter profiles share them; the battery profile keeps its
  document format and classes.
- Move ProfileBaseModel, the strict base of profile documents, into
  profilestore.
- Serve inverter profiles through the profile REST API. Refuse to delete a
  profile that a configured device uses and that has no packaged profile
  to revert to (409).
- Share the measurement access of the device settings in
  devicemeasurement.
- Rename check_battery_profiles to check_device_profiles; the device
  profile check at configuration setup covers inverters, too.
- Document inverter profiles, their configuration, defaults and sharing;
  regenerate the configuration and OpenAPI documentation.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
This commit is contained in:
Bobby Noelte
2026-11-11 22:08:18 +01:00
co-authored by Claude Opus 5.5
parent e255f987bf
commit faf37abfe7
45 changed files with 3235 additions and 784 deletions
+53
View File
@@ -9,6 +9,7 @@ from fastapi import FastAPI
from fastapi.testclient import TestClient
from akkudoktoreos.devices.profile.batteryprofile import BatteryProfileSettings
from akkudoktoreos.devices.profile.inverterprofile import InverterProfileSettings
from akkudoktoreos.devices.profile.profilestore import ProfileStore, get_profile_store
from akkudoktoreos.server.rest.error import register_problem_handlers
from akkudoktoreos.server.rest.profile import router
@@ -60,6 +61,16 @@ class TestRead:
assert response.json()["chemistry"] == "LFP"
BatteryProfileSettings.model_validate(response.json())
def test_inverter_profiles(self, client):
assert "inverter" in client.get("/v1/profile").json()
listed = client.get("/v1/profile/inverter").json()
assert {"name": "generic-hybrid", "source": "package", "packaged": True} in listed
schema = client.get("/v1/profile/inverter/schema").json()
assert "power_derating" in schema["properties"]
response = client.get("/v1/profile/inverter/generic-hybrid")
assert response.status_code == 200
InverterProfileSettings.model_validate(response.json())
def test_errors_are_problem_details(self, client):
response = client.get("/v1/profile/nope")
assert response.headers["content-type"] == "application/problem+json"
@@ -169,6 +180,48 @@ class TestDelete:
def test_delete_of_a_missing_profile_is_404(self, client):
assert client.delete("/v1/profile/battery/does-not-exist").status_code == 404
@pytest.mark.parametrize("devices", ["batteries", "electric_vehicles"])
def test_delete_of_a_battery_profile_in_use_is_409(
self, client, config_eos, generic_lfp, devices
):
client.put("/v1/profile/battery/my-battery", json=generic_lfp)
config_eos.merge_settings_from_dict(
{"devices": {devices: {"unit1": {"device_id": "unit1", "battery_profile": "my-battery"}}}}
)
response = client.delete("/v1/profile/battery/my-battery")
assert response.status_code == 409
assert response.json()["title"] == "Profile in use"
assert "unit1" in response.json()["detail"]
assert client.get("/v1/profile/battery/my-battery").status_code == 200
def test_delete_of_an_inverter_profile_in_use_is_409(self, client, config_eos):
generic_hybrid = client.get("/v1/profile/inverter/generic-hybrid").json()
client.put("/v1/profile/inverter/my-inverter", json=generic_hybrid)
config_eos.merge_settings_from_dict(
{
"devices": {
"inverters": {
"inverter1": {"device_id": "inverter1", "inverter_profile": "my-inverter"}
}
}
}
)
response = client.delete("/v1/profile/inverter/my-inverter")
assert response.status_code == 409
assert "inverter1" in response.json()["detail"]
# A battery profile of the same name is not in use.
assert client.delete("/v1/profile/battery/my-inverter").status_code == 404
def test_delete_of_an_override_in_use_reverts_to_the_packaged_profile(
self, client, config_eos, generic_lfp
):
client.put("/v1/profile/battery/generic-lfp", json=generic_lfp)
config_eos.merge_settings_from_dict(
{"devices": {"batteries": {"battery1": {"device_id": "battery1"}}}}
)
assert config_eos.devices.batteries["battery1"].battery_profile == "generic-lfp"
assert client.delete("/v1/profile/battery/generic-lfp").status_code == 200
def test_eos_app_serves_the_profile_api(config_eos):
from akkudoktoreos.server.eos import app