The file cache keyed provider request methods on their arguments and
code only. They take no arguments besides self and read location,
planes, tokens and past days from the configuration, so after a
configuration change they got the response for the previous one until
the 1-hour TTL expired, also across restarts.
cache_in_file takes an optional key_context, called with the arguments
of each call; a hash of its result is part of the key. Each provider
request declares the settings it is built from with
cache_request("general/latitude", ...), which builds the key context
from them. A change of other settings, e.g. an import value or a tariff
that an adapter pushes on every run, keeps the cache entry. The MD5
digest of the declared values is computed once per settings generation:
ConfigEOS.settings_generation() counts every _setup() (merge, reset,
revert, update) and every set_nested_value().
cache_in_file also takes key_context_hold: after a change of the key
context, a further change within the hold keeps using the valid entry
of the context in use. The first change, a change after the hold and a
forced update apply at once. A result is only stored under the context
it was computed for. cache_request passes its keyword arguments on to
cache_in_file; with_ttl defaults to REQUEST_CACHE_TTL (1 hour) and also
sets key_context_hold, so settings changes cause at most one extra
request per provider and TTL.
In a simulation of 6 hours of 5-minute runs with an import value pushed
on every run and four location and plane edits, the weather and PV
requests run 6 times (as on main), and every edit reaches the provider
within the hour.
Additional changes
Test that every cached request declares the settings it reads, including
those read by helper methods of its module
Test the settings generation counter, the reuse of the digest, the hold
and the cache_request defaults and pass-through
Add general/timezone to BrightSky (in the URL) and Forecast.Solar
(fallback zone of the response)
Clear the hold state with the whole file cache
Add a CHANGELOG entry
Refs: #1559
Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
Additional fixes
Measurement.meter_energy_kwh converts meter energy over the whole period in one read; the 31-day and 10000-interval limits apply to the public energy queries only.
Load intervals a meter does not fully cover are NaN and the load adjustment skips them; load_total_kwh returns an empty array for an empty store and keeps full last intervals.
The load adjustment compares over the period the load meters report, skips a stale load meter period and says when no load meter is configured.
PV calibration, snow feedback and the load adjustment fall back without measurements when a conversion fails, logged as error once per failure streak and consumer.
Measurement.keys_first_datetime and keys_last_datetime find each meter's first and last valid reading in bounded scans, keep each meter's newest reading and return stamps in the configured zone.
Measurement.keys_common_period derives the common meter period for PV calibration and the load adjustment and names the meter that ends it, also when meters share no period.
PV calibration warns once per stale period when a stopped PV meter holds it on old data; snow feedback warns once about a stale feedback meter.
Lasting meter conditions (silent, reset, gap, replaced meter, no shared period) are warned once per condition and consumer through one helper and warned again when they recur.
A replaced meter whose readings touch the new one is reported; a single reading is not; a meter group waiting for its second reading is an info once.
The PV meter resolution is detected from valid readings only (pre-existing), using one shared valid-reading rule in energy.py.
Stale meter stamps are compared with compare_datetimes; new meter tests create durations with datetimeutil.
The unused legacy Measurement._energy_from_meter_readings is removed; its test scenarios cover meter_energy_kwh.
The converter's range error no longer mentions the API's 31-day limit, and its duplicate interval check is gone.
Measurement and prediction docs describe the meter coverage rule, even gap spreading and when the load forecast stays unadjusted.
Tests reset the warn-once state of the shared measurement store and restore the EMS start they change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
Additional fixes
PV meter energy comes from the quality-aware conversion.
Calibration rows are binned by interval start with end-stamped rows.
The fit covers only the period every PV meter covers and stays inside its lookback.
The meter resolution is judged only where every PV meter reports.
Snow feedback derives its window from the same slot window helper and shares one PV meter read per forecast with calibration.
Window bounds and pandas timestamps are converted in one place, always to UTC; fit days are counted in the configured zone.
Calibration tests write meters in bulk, stamp them in the configured zone and check every azimuth bin; snow feedback has its own slot window test.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
Port local PV modeling and outage calibration from feature commits f976335, 6dc58c3 and faed0fd by Andreas. Keep PVForecastAkkudoktor identity and remote default, adapt to async storage, and migrate legacy provider settings.