A battery profile describes a battery model: the charge and discharge limit
maps over temperature and SoC, the charge and discharge efficiency curves
over C-rate, the technical SoC bounds, the hard temperature cutoffs and,
for a model, its nominal capacity and power limits. EOS packages the
generic profile generic-lfp; users add their own profiles.
A battery or electric vehicle selects its profile by battery_profile and
describes how the installation differs from it in profile_adjustment
(capacity, power limits of the installation, periodic full charge). The
effective values are resolved from both at the measured operating point
(temperature, SoC, power) and shown as effective_* fields.
The GENETIC simulation uses the limits and efficiencies of the profile over
SoC, with precomputed tables as a fast path; GENETIC0 gets the values at the
operating point. Optimization parameters are always valid: a battery whose
profile is missing, unreadable or invalid uses the packaged generic-lfp
profile, and the former defaults only if that is not usable either; each is
logged as error, and an optimization run is never cancelled because of a
battery.
Additional changes
- Add a generic device profile store: user and packaged profiles, atomic
saves, compiled profiles cached per file and checked again at most once a
second, plain file names as profile names ('schema' is reserved). On
Windows, a save or read that collides with the other is retried briefly.
- Add the REST API /v1/profile to list the profile kinds and to list, read
(document and JSON schema), save and delete profiles.
- Check the hard temperature cutoffs on the exact temperature.
- Resolve inhibited charging or discharging to a power of 0, e.g. for a cold
battery; give GENETIC0 its own discharge limit for that.
- Limit generic profiles without own power limits to the former 5000 W.
- Accept only the implemented units; current limits need the nominal
voltage.
- Migrate legacy battery settings into the profile adjustment, keep the
former charge power limit as discharge limit (also for a Home Assistant
entity on it) and report dropped efficiencies as errors.
- Limit GENETIC battery discharge by the discharge power.
- Allow battery profile lookups while the configuration is created.
- Resolve a battery once per configuration dump.
- Package the bundled profiles, document battery profiles and regenerate
the configuration and OpenAPI documentation.
- Ignore the report PDFs written by the visualization tests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
Regression tests were scattered across feature- and bug-specific files, and some suites repeated the same checks. Group tests by responsibility, isolate feature fixtures in test classes, and remove duplicate or obsolete cases.
The review covered all 127 collected test modules on main. This reduces them and removes or combines definitions:.
No application code changes.