% SPDX-License-Identifier: Apache-2.0 # `POST /optimize` Optimization ## Introduction The `POST /optimize` API endpoint optimizes your energy management system based on various inputs including electricity prices, battery storage capacity, PV forecast, and temperature data. The `POST /optimize` optimization interface is the "classical" interface developed by Andreas at the start of the projects and used and described in his videos. It allows and requires to define all the optimization paramters on the endpoint request. :::{admonition} Warning :class: warning The `POST /optimize` endpoint interface does not regard configurations set for the parameters passed to the request. You have to set the parameters even if given in the configuration. ::: :::{admonition} Warning :class: warning To prevent automatic optimization from interfering with `POST /optimize` requests, set `ems.mode` to `DISABLED` in the configuration. ::: ## Input Payload ### Sample Request ```json { "ems": { "preis_euro_pro_wh_akku": 0.0001, "einspeiseverguetung_euro_pro_wh": [ 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007, 0.00007 ], "gesamtlast": [ 676.71, 876.19, 527.13, 468.88, 531.38, 517.95, 483.15, 472.28, 1011.68, 995.00, 1053.07, 1063.91, 1320.56, 1132.03, 1163.67, 1176.82, 1216.22, 1103.78, 1129.12, 1178.71, 1050.98, 988.56, 912.38, 704.61, 516.37, 868.05, 694.34, 608.79, 556.31, 488.89, 506.91, 804.89, 1141.98, 1056.97, 992.46, 1155.99, 827.01, 1257.98, 1232.67, 871.26, 860.88, 1158.03, 1222.72, 1221.04, 949.99, 987.01, 733.99, 592.97 ], "pv_prognose_wh": [ 0, 0, 0, 0, 0, 0, 0, 8.05, 352.91, 728.51, 930.28, 1043.25, 1106.74, 1161.69, 6018.82, 5519.07, 3969.88, 3017.96, 1943.07, 1007.17, 319.67, 7.88, 0, 0, 0, 0, 0, 0, 0, 0, 0, 5.04, 335.59, 705.32, 1121.12, 1604.79, 2157.38, 1433.25, 5718.49, 4553.96, 3027.55, 2574.46, 1720.4, 963.4, 383.3, 0, 0, 0 ], "strompreis_euro_pro_wh": [ 0.0003384, 0.0003318, 0.0003284, 0.0003283, 0.0003289, 0.0003334, 0.0003290, 0.0003302, 0.0003042, 0.0002430, 0.0002280, 0.0002212, 0.0002093, 0.0001879, 0.0001838, 0.0002004, 0.0002198, 0.0002270, 0.0002997, 0.0003195, 0.0003081, 0.0002969, 0.0002921, 0.0002780, 0.0003384, 0.0003318, 0.0003284, 0.0003283, 0.0003289, 0.0003334, 0.0003290, 0.0003302, 0.0003042, 0.0002430, 0.0002280, 0.0002212, 0.0002093, 0.0001879, 0.0001838, 0.0002004, 0.0002198, 0.0002270, 0.0002997, 0.0003195, 0.0003081, 0.0002969, 0.0002921, 0.0002780 ] }, "pv_akku": { "device_id": "battery1", "capacity_wh": 26400, "levelized_cost_of_storage_kwh": 0.12, "max_charge_power_w": 5000, "initial_soc_percentage": 80, "min_soc_percentage": 15 }, "inverter": { "device_id": "inverter1", "max_power_wh": 10000, "battery_id": "battery1", "ac_to_dc_efficiency": 0.95, "dc_to_ac_efficiency": 0.95, "max_ac_charge_power_w": 5000 }, "eauto": { "device_id": "ev1", "capacity_wh": 60000, "charging_efficiency": 0.95, "charge_rates": [0.0, 0.375, 0.5, 0.625, 0.75, 0.875, 1.0], "discharging_efficiency": 1.0, "max_charge_power_w": 11040, "initial_soc_percentage": 54, "min_soc_percentage": 0 }, "home_appliances": [ { "device_id": "dishwasher1", "consumption_wh": 2000, "duration_h": 3, "schedule_mode": "ONCE", "time_windows": null } ], "temperature_forecast": [ 18.3, 17.8, 16.9, 16.2, 15.6, 15.1, 14.6, 14.2, 14.3, 14.8, 15.7, 16.7, 17.4, 18.0, 18.6, 19.2, 19.1, 18.7, 18.5, 17.7, 16.2, 14.6, 13.6, 13.0, 12.6, 12.2, 11.7, 11.6, 11.3, 11.0, 10.7, 10.2, 11.4, 14.4, 16.4, 18.3, 19.5, 20.7, 21.9, 22.7, 23.1, 23.1, 22.8, 21.8, 20.2, 19.1, 18.0, 17.4 ], "start_solution": null } ``` ## Input Parameters ### Energy Management System (EMS) #### Battery Terminal Value (`preis_euro_pro_wh_akku`) - Unit: €/Wh - Purpose: Represents the residual value of energy stored in the battery - Impact: Lower values encourage battery depletion, higher values preserve charge at the end of the simulation. - Separation from LCOS: This value is only applied to usable battery energy remaining at the end of the optimization horizon. Battery discharge throughput is priced separately with `pv_akku.levelized_cost_of_storage_kwh`. #### Feed-in Tariff (`einspeiseverguetung_euro_pro_wh`) - Unit: €/Wh - Purpose: Compensation received for feeding excess energy back to the grid #### Total Load Forecast (`gesamtlast`) - Unit: W - Time Range: 48 hours (00:00 today to 23:00 tomorrow) - Format: Array of hourly values - Note: Exclude optimizable loads (EV charging, battery charging, etc.) ##### Data Sources 1. Standard Load Profile: `GET /v1/prediction/list?key=load_mean` for a standard load profile based on your yearly consumption. 2. Adjusted Load Profile: `GET /v1/prediction/list?key=load_mean_adjusted` for a combination of a standard load profile based on your yearly consumption incl. data from last 48h. #### PV Generation Forecast (`pv_prognose_wh`) - Unit: W - Time Range: 48 hours (00:00 today to 23:00 tomorrow) - Format: Array of hourly values - Data Source: `GET /v1/prediction/series?key=pvforecast_ac_power` #### Probabilistic Direct PV Consumption and Bypass Hourly or 15-minute mean values alone would optimistically assume that the smaller of mean PV generation and mean load is consumed directly. Real household load varies within the interval. EOS therefore uses a conditional probability table derived from one-minute load samples. For a forecast mean load \(\mu_L\), the table contains load-bin powers \(L_i\) and their conditional probabilities \(p_i = P(L=L_i\mid\mu_L)\), with \(\sum_i p_i=1\). Because the finite 50 W table grid can deviate slightly from the requested forecast mean, the load bins are first normalized without changing the shape of the distribution: ```{math} \widetilde{L}_i = L_i \frac{\mu_L}{\sum_j p_j L_j} ``` For mean PV power \(P_{PV}\), the expected power flowing directly from PV to the load is: ```{math} P_{direct} = \sum_i p_i \min\left(\widetilde{L}_i, P_{PV}\right) ``` For a slot of duration \(\Delta t\), EOS converts this power into energy and derives both residual flows from the same direct-consumption value: ```{math} \begin{aligned} E_{direct} &= \Delta t\,P_{direct} \\ E_{load,residual} &= E_{load}-E_{direct} \\ E_{PV,surplus} &= E_{PV}-E_{direct} \end{aligned} ``` The residual load is supplied by the battery and then the grid. The PV surplus charges the battery; any remainder bypasses the battery and is exported. Both residual load and PV surplus may be positive in the same coarse slot because they occur during different sub-intervals. This is expected and preserves the energy balances \(E_{direct}+E_{load,residual}=E_{load}\) and \(E_{direct}+E_{PV,surplus}=E_{PV}\). The bundled table is conditioned on a one-hour mean load and models load variation only; mean PV is treated as constant inside the slot. For a 15-minute grid produced by splitting hourly energy, the power lookup retains the original hourly mean. A native 15-minute load forecast uses the same table as an approximation until a separately calibrated 15-minute distribution is available. Fast PV variability, for example from clouds, is not represented by this table. #### Electricity Price Forecast (`strompreis_euro_pro_wh`) - Unit: €/Wh - Time Range: 48 hours (00:00 today to 23:00 tomorrow) - Format: Array of hourly values - Data Source: `GET /v1/prediction/list?key=elecprice_marketprice_wh` Verify prices against your local tariffs. ### Battery Storage System #### Configuration - `device_id`: ID of battery - `capacity_wh`: Total battery capacity in Wh - `charging_efficiency`: Charging efficiency (0-1) - `discharging_efficiency`: Discharging efficiency (0-1) - `levelized_cost_of_storage_kwh`: LCOS in EUR/kWh, charged once for every kWh of DC energy delivered by the battery. Default: `0.0`. - `max_charge_power_w`: Maximum charging power in W #### Battery LCOS (`levelized_cost_of_storage_kwh`) LCOS and terminal value have different purposes. LCOS is a variable battery-use cost and is added once when the battery delivers energy, both for local load coverage and battery-to-grid export. It is not charged when the battery is charged and is not charged again on battery-internal or DC-to-AC inverter losses. For battery-delivered DC energy `E_bat,out` in one slot: ```{math} C_{LCOS} = \frac{E_{bat,out}}{1000}\,c_{LCOS} ``` where `E_bat,out` is in Wh and `c_LCOS` is in EUR/kWh. This cost is included in `Kosten_Euro_pro_Stunde`, `Gesamtkosten_Euro`, and therefore `Gesamtbilanz_Euro`. The terminal value `preis_euro_pro_wh_akku`, by contrast, applies only to usable energy remaining after the last slot. #### State of Charge (SoC) - `initial_soc_percentage`: Current battery level (%) - `min_soc_percentage`: Minimum allowed SoC (%) - `max_soc_percentage`: Maximum allowed SoC (%) ### Inverter - `device_id`: ID of inverter - `max_power_wh`: Maximum inverter power in Wh - `battery_id`: ID of battery - `ac_to_dc_efficiency`: Efficiency of AC→DC conversion for grid-to-battery AC charging (0-1). Set to `0` to disable AC charging via inverter. Default `1.0` (backward compatible, no additional inverter loss — existing battery `charging_efficiency` applies). - `dc_to_ac_efficiency`: Efficiency of DC→AC conversion for battery discharging to AC load/grid (0-1). Must be > 0. Default `1.0` (backward compatible). - `max_ac_charge_power_w`: Maximum AC charging power in watts. `null` means no additional limit (battery's own `max_charge_power_w` applies). Set to `0` to disable AC charging. Default `null`. #### Efficiency Model The inverter efficiency parameters cleanly separate the **DC battery efficiency** from the **AC↔DC inverter conversion efficiency**: - **DC charging from PV surplus**: PV → Battery (direct DC, only `charging_efficiency` applies) - **AC charging from grid**: Grid (AC) → Inverter (`ac_to_dc_efficiency`) → Battery (`charging_efficiency`) - **Discharging to AC load/grid**: Battery (`discharging_efficiency`) → Inverter (`dc_to_ac_efficiency`) → Load/Grid (AC) Round-trip efficiency for AC charging and discharging: `η_round_trip = ac_to_dc_efficiency × charging_efficiency × discharging_efficiency × dc_to_ac_efficiency` For profitability, the discharge electricity price must exceed: `buy_price / η_round_trip + LCOS / dc_to_ac_efficiency` **Backward compatibility**: With default values (`ac_to_dc_efficiency=1.0`, `dc_to_ac_efficiency=1.0`, `max_ac_charge_power_w=null`), existing configurations work identically. To model realistic inverter losses, set both efficiencies to a value like `0.95` and adjust battery efficiencies to reflect pure DC losses only (typically `0.96`–`0.99` for Li-ion). #### AC Charging Break-Even Penalty The genetic optimizer includes an economic break-even check as a fitness penalty to guide convergence away from unprofitable AC grid charging. For each scheduled AC charging hour the optimizer checks whether the best future discharge price (after accounting for round-trip losses) actually recovers the charging cost. **Free PV energy handling**: Energy already stored in the battery from PV generation (zero grid cost) is treated as a free resource that covers the most expensive future hours first. AC grid charging is only evaluated against the *remaining* uncovered hours. The penalty magnitude is: ```text penalty = ac_wh_charged × (break_even_price − best_uncovered_price) × factor ``` where: - `break_even_price = charge_price / η_round_trip + LCOS / dc_to_ac_efficiency` - `best_uncovered_price` = highest future price not already covered by free PV battery energy - `factor` = `optimization.genetic.penalties.ac_charge_break_even` (default `1.0`) The penalty does not replace the simulation cost — it amplifies the economic loss signal so the algorithm converges faster away from unprofitable charging regions. To tune the aggressiveness of this penalty, set `penalties.ac_charge_break_even` in the optimization configuration. A value of `1.0` corresponds to the exact economic loss in €. Larger values (e.g. `3.0`) make the algorithm more aggressively avoid unprofitable AC charging; smaller values (e.g. `0.0`) disable the penalty entirely. ### Electric Vehicle (EV) - `device_id`: ID of electric vehicle - `capacity_wh`: Battery capacity in Wh - `charging_efficiency`: Charging efficiency (0-1) - `discharging_efficiency`: Discharging efficiency (0-1) - `max_charge_power_w`: Maximum charging power in W - `initial_soc_percentage`: Current charge level (%) - `min_soc_percentage`: Minimum allowed SoC (%) - `max_soc_percentage`: Maximum allowed SoC (%) ### Temperature Forecast - Unit: °C - Time Range: 48 hours (00:00 today to 23:00 tomorrow) - Format: Array of hourly values - Data Source: `GET /v1/prediction/list?key=weather_temp_air` ## Output Format ### Sample Response ```json { "ac_charge": [0.625, 0, ..., 0.75, 0], "dc_charge": [1, 1, ..., 1, 1], "discharge_allowed": [0, 0, 1, ..., 0, 0], "battery_grid_export_allowed": [0, 0, 0, ..., 1, 0], "eautocharge_hours_float": [0.625, 0, ..., 0.75, 0], "result": { "Last_Wh_pro_Stunde": [...], "EAuto_SoC_pro_Stunde": [...], "Einnahmen_Euro_pro_Stunde": [...], "Gesamt_Verluste": 1514.96, "Gesamtbilanz_Euro": 2.51, "Gesamteinnahmen_Euro": 2.88, "Gesamtkosten_Euro": 5.39, "akku_soc_pro_stunde": [...] } } ``` ### Output Parameters #### Battery Control - `ac_charge`: Grid charging schedule (0.0-1.0) - `dc_charge`: DC charging schedule (0-1) - `discharge_allowed`: Battery discharge permission for local self-consumption/load coverage (0 or 1) - `battery_grid_export_allowed`: Battery discharge permission for grid export/direct marketing (0 or 1) 0 (no charge) 1 (charge with full load) `ac_charge` multiplied by the maximum charge power of the battery results in the planned charging power. #### EV Charging - `eautocharge_hours_float`: EV charging schedule (0.0-1.0) #### Results The `result` object contains detailed information about the optimization outcome. The length of the array is between 25 and 48 and starts at the current hour and ends at 23:00 tomorrow. - `Last_Wh_pro_Stunde`: Array of hourly load values in Wh - Shows the total energy consumption per hour - Includes household load, battery charging/discharging, and EV charging - `EAuto_SoC_pro_Stunde`: Array of hourly EV state of charge values (%) - Shows the projected EV battery level throughout the optimization period - `Einnahmen_Euro_pro_Stunde`: Array of hourly revenue values in Euro - `Gesamt_Verluste`: Total energy losses in Wh - `Gesamtbilanz_Euro`: Overall financial balance in Euro - `Gesamteinnahmen_Euro`: Total revenue in Euro - `Gesamtkosten_Euro`: Total costs in Euro - `akku_soc_pro_stunde`: Array of hourly battery state of charge values (%) ## Timeframe overview ```{figure} ../_static/optimization_timeframes.png :alt: Timeframe Overview Timeframe Overview ```