"""Estimate effective model capacity from independent SoC anchors and DC power.""" from datetime import datetime from math import isfinite from typing import TYPE_CHECKING, Literal from pydantic import AwareDatetime, BaseModel, ConfigDict, Field, model_validator from akkudoktoreos.config.configabc import SettingsBaseModel from akkudoktoreos.measurement.quality import SampleQuality if TYPE_CHECKING: from akkudoktoreos.measurement.measurement import MeasurementChannelSettings class BatteryCapacityEstimationSettings(SettingsBaseModel): """Only a battery-terminal DC power channel is supported, not inverter AC.""" power_key: str = Field(min_length=1) positive_power: Literal["charging", "discharging"] measurement_boundary: Literal["battery_dc"] = "battery_dc" min_soc_change_percentage: float = Field(default=20, gt=0, le=100) max_duration_hours: float = Field(default=168, gt=0, le=744) class CapacityModel(BaseModel): model_config = ConfigDict(extra="forbid", allow_inf_nan=False) class BatteryCapacityRequest(CapacityModel): """Caller attests both anchors are independent of the capacity being fitted. End is the first confirmed full point when using the default end SoC. Voltage/current anchors must be independently established for the chemistry. """ start: AwareDatetime end: AwareDatetime start_soc_percentage: float = Field(ge=0, le=100) end_soc_percentage: float = Field(default=100, ge=0, le=100) soc_reference: Literal["bms", "external_calibration", "voltage_current_anchor"] store_estimate: bool = False @model_validator(mode="after") def ordered(self) -> "BatteryCapacityRequest": if self.end.timestamp() <= self.start.timestamp(): raise ValueError("end must be after start.") return self class BatteryCapacityEstimate(CapacityModel): battery_id: str start: AwareDatetime end: AwareDatetime soc_reference: str start_soc_percentage: float end_soc_percentage: float estimated_capacity_wh: float configured_capacity_wh: float capacity_change_percentage: float model_end_soc_percentage_unclipped: float model_soc_error_percentage_points: float charge_energy_wh: float discharge_energy_wh: float stored_energy_change_wh: float charging_efficiency: float discharging_efficiency: float power_key: str positive_power: str integration_method: str coverage_seconds: float samples_used: int warnings: list[str] def estimate_capacity( request: BatteryCapacityRequest, settings: BatteryCapacityEstimationSettings, channel: "MeasurementChannelSettings", samples: list[tuple[datetime, float | None, SampleQuality]], *, battery_id: str, capacity_wh: float, charging_efficiency: float, discharging_efficiency: float, ) -> BatteryCapacityEstimate: """Fit C in C * delta_soc = eta_c * E_charge - E_discharge / eta_d. No clipping at 0/100%, extrapolation, gap filling or efficiency fitting. Linear segments are split at zero before applying directional efficiencies. """ left, right = request.start.timestamp(), request.end.timestamp() if right - left > settings.max_duration_hours * 3600: raise ValueError("Requested period exceeds capacity_estimation.max_duration_hours.") delta_soc = (request.end_soc_percentage - request.start_soc_percentage) / 100 if abs(delta_soc) * 100 + 1e-9 < settings.min_soc_change_percentage: raise ValueError( "Independent SoC change is too small; full-to-full cannot identify capacity." ) if channel.quantity != "power": raise ValueError("Capacity estimation requires signed battery DC power in W or kW.") max_gap_seconds = channel.max_gap_seconds integration_method = channel.integration_method if max_gap_seconds is None or integration_method is None: raise ValueError("Power channels require an integration method and maximum sample gap.") if not isfinite(capacity_wh) or capacity_wh <= 0: raise ValueError("Configured capacity must be positive and finite.") if not all(isfinite(e) and 0 < e <= 1 for e in (charging_efficiency, discharging_efficiency)): raise ValueError("Battery efficiencies must be finite and in (0, 1].") points = [] for time, value, quality in samples: if time.tzinfo is None or time.utcoffset() is None: raise ValueError("Explicit sample timezone required.") points.append((time.timestamp(), value, quality)) points.sort(key=lambda row: row[0]) if any(a[0] == b[0] for a, b in zip(points, points[1:])): raise ValueError("Duplicate power sample timestamps.") factor = (1000 if channel.unit == "kW" else 1) * ( 1 if settings.positive_power == "charging" else -1 ) charge = discharge = coverage = 0.0 cumulative_net = 0.0 minimum_net = maximum_net = 0.0 used: set[float] = set() cursor = left for (a, va, qa), (b, vb, qb) in zip(points, points[1:]): lo, hi = max(left, a), min(right, b) if hi <= lo: continue if lo > cursor + 1e-6 or b - a > max_gap_seconds: raise ValueError("Incomplete power coverage or sample gap exceeds max_gap_seconds.") if ( va is None or vb is None or any(isinstance(v, bool) or not isfinite(v) for v in (va, vb)) or qa.status != "measured" or qb.status != "measured" ): raise ValueError( "Capacity estimation requires finite measured power samples throughout." ) if qb.reset or qa.generation != qb.generation: raise ValueError("Power sensor reset or generation change within the period.") p, q = va * factor, vb * factor if integration_method == "linear": slope = (q - p) / (b - a) p, q = p + slope * (lo - a), p + slope * (hi - a) else: q = p duration = hi - lo if p * q < 0: first = duration * abs(p) / (abs(p) + abs(q)) parts = [(p * first / 7200), (q * (duration - first) / 7200)] else: parts = [(p + q) * duration / 7200] charge += sum(max(0, energy) for energy in parts) discharge += sum(max(0, -energy) for energy in parts) for energy in parts: cumulative_net += ( energy * charging_efficiency if energy >= 0 else energy / discharging_efficiency ) minimum_net = min(minimum_net, cumulative_net) maximum_net = max(maximum_net, cumulative_net) coverage += duration cursor = hi used.update((a, b)) if cursor < right - 1e-6 or abs(coverage - (right - left)) > 1e-6: raise ValueError("Incomplete power coverage; no extrapolation to the SoC anchors.") net = charge * charging_efficiency - discharge / discharging_efficiency capacity = net / delta_soc if not isfinite(capacity) or capacity <= 0: raise ValueError("Energy flow disagrees with SoC change; check polarity and anchors.") if ( request.start_soc_percentage + minimum_net / capacity * 100 < -1e-6 or request.start_soc_percentage + maximum_net / capacity * 100 > 100 + 1e-6 ): raise ValueError( "Fitted SoC leaves 0..100% within the period; check anchors and use the first full point." ) model_end = request.start_soc_percentage + net / capacity_wh * 100 warnings = [ "Conditional estimate: SoC anchors, DC measurement boundary and configured efficiencies must be correct.", "A single interval cannot independently identify both capacity and efficiencies.", "The active capacity_wh is unchanged.", ] if request.soc_reference == "voltage_current_anchor": warnings.append( "Voltage/current anchors depend on chemistry, temperature and operating conditions." ) return BatteryCapacityEstimate( battery_id=battery_id, start=request.start, end=request.end, soc_reference=request.soc_reference, start_soc_percentage=request.start_soc_percentage, end_soc_percentage=request.end_soc_percentage, estimated_capacity_wh=capacity, configured_capacity_wh=capacity_wh, capacity_change_percentage=(capacity / capacity_wh - 1) * 100, model_end_soc_percentage_unclipped=model_end, model_soc_error_percentage_points=model_end - request.end_soc_percentage, charge_energy_wh=charge, discharge_energy_wh=discharge, stored_energy_change_wh=net, charging_efficiency=charging_efficiency, discharging_efficiency=discharging_efficiency, power_key=settings.power_key, positive_power=settings.positive_power, integration_method=integration_method, coverage_seconds=coverage, samples_used=len(used), warnings=warnings, )