Files
EOS/docs/_generated/configdevices.md
AndreasandClaude Opus 4.8 67cf6f7d8a feat(optimization): schedule any number of flexible consumers
Replace the single hourly "dishwasher" home appliance with a list of
flexible consumers (home_appliances). Each consumer defines its load
either as an explicit power profile (energy-preservingly resampled onto
the optimization slot grid, incl. 15-min and non-integer interval ratios)
or the flat consumption_wh/duration_h fallback, and runs ONCE or DAILY
within its time windows and the optimization horizon.

- ConsumerScheduleMode + shared load-definition validation (XOR of
  profile/fallback, reject negative/NaN/inf, unique device_id)
- ApplianceGeneLayout: variable appliance gene block (index into
  allowed_start_slots), ONCE/DAILY calendar-day based, no snapping
- per-device output: result.home_appliance_energy_wh, appliance_starts
  (absolute local times), per-device solution columns and DDBC RUN/OFF
  instructions on state transitions only
- deprecate dishwasher/washingstart/Home_appliance_wh_per_hour with
  backward-compatible mapping and explicit conflict rejection
- max_home_appliances is now an upper bound only; no demo appliance and
  no on/off behaviour
- docs, openapi.json, CHANGELOG and optimize_result_2* fixtures updated;
  new tests/test_homeappliance.py covers the mandatory test matrix

Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
2026-07-15 14:19:46 +02:00

22 KiB

Base configuration for devices simulation settings

:::{table} devices :widths: 10 20 10 5 5 30 :align: left

Name Environment Variable Type Read-Only Default Description
batteries EOS_DEVICES__BATTERIES Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]] rw None List of battery devices
electric_vehicles EOS_DEVICES__ELECTRIC_VEHICLES Optional[list[akkudoktoreos.devices.devices.BatteriesCommonSettings]] rw None List of electric vehicle devices
home_appliances EOS_DEVICES__HOME_APPLIANCES Optional[list[akkudoktoreos.devices.devices.HomeApplianceCommonSettings]] rw None List of home appliances
inverters EOS_DEVICES__INVERTERS Optional[list[akkudoktoreos.devices.devices.InverterCommonSettings]] rw None List of inverters
max_batteries EOS_DEVICES__MAX_BATTERIES Optional[int] rw None Maximum number of batteries that can be set
max_electric_vehicles EOS_DEVICES__MAX_ELECTRIC_VEHICLES Optional[int] rw None Maximum number of electric vehicles that can be set
max_home_appliances EOS_DEVICES__MAX_HOME_APPLIANCES Optional[int] rw None Maximum number of home_appliances that can be set
max_inverters EOS_DEVICES__MAX_INVERTERS Optional[int] rw None Maximum number of inverters that can be set
measurement_keys Optional[list[str]] ro N/A Return the measurement keys for the resource/ device stati that are measurements.
:::

Example Input

   {
       "devices": {
           "batteries": [
               {
                   "device_id": "battery1",
                   "capacity_wh": 8000,
                   "charging_efficiency": 0.88,
                   "discharging_efficiency": 0.88,
                   "levelized_cost_of_storage_kwh": 0.0,
                   "max_charge_power_w": 5000,
                   "min_charge_power_w": 50,
                   "charge_rates": [
                       0.0,
                       0.1,
                       0.2,
                       0.3,
                       0.4,
                       0.5,
                       0.6,
                       0.7,
                       0.8,
                       0.9,
                       1.0
                   ],
                   "min_soc_percentage": 0,
                   "max_soc_percentage": 100
               }
           ],
           "max_batteries": 1,
           "electric_vehicles": [
               {
                   "device_id": "battery1",
                   "capacity_wh": 8000,
                   "charging_efficiency": 0.88,
                   "discharging_efficiency": 0.88,
                   "levelized_cost_of_storage_kwh": 0.0,
                   "max_charge_power_w": 5000,
                   "min_charge_power_w": 50,
                   "charge_rates": [
                       0.0,
                       0.1,
                       0.2,
                       0.3,
                       0.4,
                       0.5,
                       0.6,
                       0.7,
                       0.8,
                       0.9,
                       1.0
                   ],
                   "min_soc_percentage": 0,
                   "max_soc_percentage": 100
               }
           ],
           "max_electric_vehicles": 1,
           "inverters": [],
           "max_inverters": 1,
           "home_appliances": [],
           "max_home_appliances": 1
       }
   }

Example Output

   {
       "devices": {
           "batteries": [
               {
                   "device_id": "battery1",
                   "capacity_wh": 8000,
                   "charging_efficiency": 0.88,
                   "discharging_efficiency": 0.88,
                   "levelized_cost_of_storage_kwh": 0.0,
                   "max_charge_power_w": 5000,
                   "min_charge_power_w": 50,
                   "charge_rates": [
                       0.0,
                       0.1,
                       0.2,
                       0.3,
                       0.4,
                       0.5,
                       0.6,
                       0.7,
                       0.8,
                       0.9,
                       1.0
                   ],
                   "min_soc_percentage": 0,
                   "max_soc_percentage": 100,
                   "measurement_key_soc_factor": "battery1-soc-factor",
                   "measurement_key_power_l1_w": "battery1-power-l1-w",
                   "measurement_key_power_l2_w": "battery1-power-l2-w",
                   "measurement_key_power_l3_w": "battery1-power-l3-w",
                   "measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
                   "measurement_keys": [
                       "battery1-soc-factor",
                       "battery1-power-l1-w",
                       "battery1-power-l2-w",
                       "battery1-power-l3-w",
                       "battery1-power-3-phase-sym-w"
                   ]
               }
           ],
           "max_batteries": 1,
           "electric_vehicles": [
               {
                   "device_id": "battery1",
                   "capacity_wh": 8000,
                   "charging_efficiency": 0.88,
                   "discharging_efficiency": 0.88,
                   "levelized_cost_of_storage_kwh": 0.0,
                   "max_charge_power_w": 5000,
                   "min_charge_power_w": 50,
                   "charge_rates": [
                       0.0,
                       0.1,
                       0.2,
                       0.3,
                       0.4,
                       0.5,
                       0.6,
                       0.7,
                       0.8,
                       0.9,
                       1.0
                   ],
                   "min_soc_percentage": 0,
                   "max_soc_percentage": 100,
                   "measurement_key_soc_factor": "battery1-soc-factor",
                   "measurement_key_power_l1_w": "battery1-power-l1-w",
                   "measurement_key_power_l2_w": "battery1-power-l2-w",
                   "measurement_key_power_l3_w": "battery1-power-l3-w",
                   "measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
                   "measurement_keys": [
                       "battery1-soc-factor",
                       "battery1-power-l1-w",
                       "battery1-power-l2-w",
                       "battery1-power-l3-w",
                       "battery1-power-3-phase-sym-w"
                   ]
               }
           ],
           "max_electric_vehicles": 1,
           "inverters": [],
           "max_inverters": 1,
           "home_appliances": [],
           "max_home_appliances": 1,
           "measurement_keys": [
               "battery1-soc-factor",
               "battery1-power-l1-w",
               "battery1-power-l2-w",
               "battery1-power-l3-w",
               "battery1-power-3-phase-sym-w",
               "battery1-soc-factor",
               "battery1-power-l1-w",
               "battery1-power-l2-w",
               "battery1-power-l3-w",
               "battery1-power-3-phase-sym-w"
           ]
       }
   }

Inverter devices base settings

:::{table} devices::inverters::list :widths: 10 10 5 5 30 :align: left

Name Type Read-Only Default Description
ac_to_dc_efficiency float rw 1.0 Efficiency of AC to DC conversion for grid-to-battery AC charging (0-1). Set to 0 to disable AC charging. Default 1.0 (no additional inverter loss).
battery_id Optional[str] rw None ID of battery controlled by this inverter.
dc_to_ac_efficiency float rw 1.0 Efficiency of DC to AC conversion for battery discharging to AC load/grid (0-1). Default 1.0 (no additional inverter loss).
device_id str rw <unknown> ID of device
max_ac_charge_power_w Optional[float] rw None Maximum AC charging power in watts. null means no additional limit. Set to 0 to disable AC charging.
max_power_w Optional[float] rw None Maximum power [W].
measurement_keys Optional[list[str]] ro N/A Measurement keys for the inverter stati that are measurements.
:::

Example Input

   {
       "devices": {
           "inverters": [
               {
                   "device_id": "battery1",
                   "max_power_w": 10000.0,
                   "battery_id": null,
                   "ac_to_dc_efficiency": 0.95,
                   "dc_to_ac_efficiency": 0.95,
                   "max_ac_charge_power_w": null
               }
           ]
       }
   }

Example Output

   {
       "devices": {
           "inverters": [
               {
                   "device_id": "battery1",
                   "max_power_w": 10000.0,
                   "battery_id": null,
                   "ac_to_dc_efficiency": 0.95,
                   "dc_to_ac_efficiency": 0.95,
                   "max_ac_charge_power_w": null,
                   "measurement_keys": []
               }
           ]
       }
   }

Model defining a daily or date time window with optional localization support

Represents a time interval starting at start_time and lasting for duration. Can restrict applicability to a specific day of the week or a specific calendar date. Supports day names in multiple languages via locale-aware parsing.

Timezone contract:

start_time is always naive (no tzinfo). It is interpreted as a local wall-clock time in whatever timezone the caller's date_time or reference_date carries. When those arguments are timezone-aware the window boundaries are evaluated in that timezone; when they are naive, arithmetic is performed as-is (no timezone conversion occurs).

date, being a calendar Date object, is inherently timezone-free.

This design avoids the ambiguity that arises when a stored start_time carries its own timezone that differs from the caller's timezone, and keeps the model serialisable without timezone state.

:::{table} devices::home_appliances::list::time_windows::windows::list :widths: 10 10 5 5 30 :align: left

Name Type Read-Only Default Description
date Optional[pydantic_extra_types.pendulum_dt.Date] rw None Optional specific calendar date for the time window. Naive — matched against the local date of the datetime passed to contains(). Overrides day_of_week if set.
day_of_week Union[int, str, NoneType] rw None Optional day of the week restriction. Can be specified as integer (0=Monday to 6=Sunday) or localized weekday name. If None, applies every day unless date is set.
duration Duration rw required Duration of the time window starting from start_time.
locale Optional[str] rw None Locale used to parse weekday names in day_of_week when given as string. If not set, Pendulum's default locale is used. Examples: 'en', 'de', 'fr', etc.
start_time Time rw required Naive start time of the time window (time of day, no timezone). Interpreted in the timezone of the datetime passed to contains() or earliest_start_time().
:::

Example Input/Output

   {
       "devices": {
           "home_appliances": [
               {
                   "time_windows": {
                       "windows": [
                           {
                               "start_time": "00:00:00.000000",
                               "duration": "2 hours",
                               "day_of_week": null,
                               "date": null,
                               "locale": null
                           }
                       ]
                   }
               }
           ]
       }
   }

Model representing a sequence of time windows with collective operations

Manages multiple TimeWindow objects and provides methods to work with them as a cohesive unit for scheduling and availability checking.

:::{table} devices::home_appliances::list::time_windows :widths: 10 10 5 5 30 :align: left

Name Type Read-Only Default Description
windows list[akkudoktoreos.config.configabc.TimeWindow] rw required List of TimeWindow objects that make up this sequence.
:::

Example Input/Output

   {
       "devices": {
           "home_appliances": [
               {
                   "time_windows": {
                       "windows": []
                   }
               }
           ]
       }
   }

Flexible consumer (home appliance) devices base settings

A consumer's load is defined either by an explicit power profile (load_profile_power_w with an optional load_profile_interval_seconds) or by the flat fallback consumption_wh + duration_h. Exactly one of the two must be provided.

:::{table} devices::home_appliances::list :widths: 10 10 5 5 30 :align: left

Name Type Read-Only Default Description
consumption_wh Optional[int] rw None Flat fallback: total energy consumption of one run [Wh]. Used only when no load_profile_power_w is given.
device_id str rw <unknown> ID of device
duration_h Optional[int] rw None Flat fallback: run duration in hours [0 ... 24]. Used only when no load_profile_power_w is given.
load_profile_interval_seconds Optional[int] rw None Duration of one 'load_profile_power_w' step in seconds. Defaults to the configured optimization interval when a profile is given.
load_profile_power_w Optional[list[float]] rw None Explicit load profile describing a single complete run as a sequence of non-negative power values in watts (e.g. [200.0, 2000.0, 1800.0, 100.0]). Each value covers 'load_profile_interval_seconds'. Mutually exclusive with consumption_wh/duration_h.
measurement_keys Optional[list[str]] ro N/A Measurement keys for the home appliance stati that are measurements.
schedule_mode <enum 'ConsumerScheduleMode'> rw ONCE Scheduling mode: ONCE (a single run within the horizon) or DAILY (one run per local calendar day with a feasible full run).
time_windows Optional[akkudoktoreos.config.configabc.TimeWindowSequence] rw None Sequence of allowed time windows. Defaults to optimization general time window.
:::

Example Input

   {
       "devices": {
           "home_appliances": [
               {
                   "device_id": "battery1",
                   "load_profile_power_w": null,
                   "load_profile_interval_seconds": null,
                   "schedule_mode": "ONCE",
                   "consumption_wh": 2000,
                   "duration_h": 1,
                   "time_windows": {
                       "windows": [
                           {
                               "start_time": "10:00:00.000000",
                               "duration": "2 hours",
                               "day_of_week": null,
                               "date": null,
                               "locale": null
                           }
                       ]
                   }
               }
           ]
       }
   }

Example Output

   {
       "devices": {
           "home_appliances": [
               {
                   "device_id": "battery1",
                   "load_profile_power_w": null,
                   "load_profile_interval_seconds": null,
                   "schedule_mode": "ONCE",
                   "consumption_wh": 2000,
                   "duration_h": 1,
                   "time_windows": {
                       "windows": [
                           {
                               "start_time": "10:00:00.000000",
                               "duration": "2 hours",
                               "day_of_week": null,
                               "date": null,
                               "locale": null
                           }
                       ]
                   },
                   "measurement_keys": []
               }
           ]
       }
   }

Battery devices base settings

:::{table} devices::batteries::list :widths: 10 10 5 5 30 :align: left

Name Type Read-Only Default Description
capacity_wh int rw 8000 Capacity [Wh].
charge_rates Optional[list[float]] rw [0.0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0] Charge rates as factor of maximum charging power [0.00 ... 1.00]. None triggers fallback to default charge-rates.
charging_efficiency float rw 0.88 Charging efficiency [0.01 ... 1.00].
device_id str rw <unknown> ID of device
discharging_efficiency float rw 0.88 Discharge efficiency [0.01 ... 1.00].
levelized_cost_of_storage_kwh float rw 0.0 Levelized cost of storage (LCOS), applied once to each kWh delivered by the battery [€/kWh].
max_charge_power_w Optional[float] rw 5000 Maximum charging power [W].
max_soc_percentage int rw 100 Maximum state of charge (SOC) as percentage of capacity [%].
measurement_key_power_3_phase_sym_w str ro N/A Measurement key for the symmetric 3 phase power the battery is charged or discharged with [W].
measurement_key_power_l1_w str ro N/A Measurement key for the L1 power the battery is charged or discharged with [W].
measurement_key_power_l2_w str ro N/A Measurement key for the L2 power the battery is charged or discharged with [W].
measurement_key_power_l3_w str ro N/A Measurement key for the L3 power the battery is charged or discharged with [W].
measurement_key_soc_factor str ro N/A Measurement key for the battery state of charge (SoC) as factor of total capacity [0.0 ... 1.0].
measurement_keys Optional[list[str]] ro N/A Measurement keys for the battery stati that are measurements.
min_charge_power_w Optional[float] rw 50 Minimum charging power [W].
min_soc_percentage int rw 0 Minimum state of charge (SOC) as percentage of capacity [%]. This is the target SoC for charging
:::

Example Input

   {
       "devices": {
           "batteries": [
               {
                   "device_id": "battery1",
                   "capacity_wh": 8000,
                   "charging_efficiency": 0.88,
                   "discharging_efficiency": 0.88,
                   "levelized_cost_of_storage_kwh": 0.12,
                   "max_charge_power_w": 5000.0,
                   "min_charge_power_w": 50.0,
                   "charge_rates": [
                       0.0,
                       0.25,
                       0.5,
                       0.75,
                       1.0
                   ],
                   "min_soc_percentage": 10,
                   "max_soc_percentage": 100
               }
           ]
       }
   }

Example Output

   {
       "devices": {
           "batteries": [
               {
                   "device_id": "battery1",
                   "capacity_wh": 8000,
                   "charging_efficiency": 0.88,
                   "discharging_efficiency": 0.88,
                   "levelized_cost_of_storage_kwh": 0.12,
                   "max_charge_power_w": 5000.0,
                   "min_charge_power_w": 50.0,
                   "charge_rates": [
                       0.0,
                       0.25,
                       0.5,
                       0.75,
                       1.0
                   ],
                   "min_soc_percentage": 10,
                   "max_soc_percentage": 100,
                   "measurement_key_soc_factor": "battery1-soc-factor",
                   "measurement_key_power_l1_w": "battery1-power-l1-w",
                   "measurement_key_power_l2_w": "battery1-power-l2-w",
                   "measurement_key_power_l3_w": "battery1-power-l3-w",
                   "measurement_key_power_3_phase_sym_w": "battery1-power-3-phase-sym-w",
                   "measurement_keys": [
                       "battery1-soc-factor",
                       "battery1-power-l1-w",
                       "battery1-power-l2-w",
                       "battery1-power-l3-w",
                       "battery1-power-3-phase-sym-w"
                   ]
               }
           ]
       }
   }