4693e1fa97 fix(genetic): keep a started home appliance run until the device reports it finished
A re-plan treated a running home appliance as not started. In its start
slot it could pick another start of equal cost and switch the appliance
off; after the start slot it could only plan a new complete run later; and
when no complete run fitted into the rest of the window, the DAILY cycle
was dropped and the running appliance got OFF.

The executor now reports the start of a planned run as UNIX seconds under
`<device_id>.run_started_at` (setting `run_started_measurement_key`) and 0
when the device reports the run as finished. The device decides when that
is, also before or after the configured duration. Until then the GENETIC
optimizer places the remaining energy from now on as fixed load,
independent of windows, deadline and genes, sends RUN, counts the run as a
cycle of its start day and plans further cycles after its end and gap. A
run past its duration keeps the current slot without extra energy; a start
more than two run durations ago, or an invalid value, is logged and
ignored.

Refs: #1548
Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
2026-11-15 13:54:22 +01:00
..