% SPDX-License-Identifier: Apache-2.0 (measurement-page)=
Measurements
Measurements are utilized to refine predictions using real data from your system, thereby enhancing accuracy.
- Household Load Measurement
- Grid Export Measurement
- Grid Import Measurement
Storing Measurements
EOS stores measurements in a key-value store, where the term measurement key refers to the
unique identifier used to store and retrieve specific measurement data.
Several endpoints of the EOS REST server allow for the management and retrieval of these measurements.
The measurement data must be or is provided in one of the following formats:
1. DateTimeData
A dictionary with the following structure:
{
"start_datetime": "2024-01-01 00:00:00",
"interval": "1 hour",
"<measurement key>": [value, value, ...],
"<measurement key>": [value, value, ...],
...
}
2. DateTimeDataFrame
A JSON string created from a pandas dataframe with a
DatetimeIndex. Use pandas.DataFrame.to_json(orient="index").
The column name of the data must be the same as the names of the measurement keys.
3. DateTimeSeries
A JSON string created from a pandas series with a
DatetimeIndex. Use pandas.Series.to_json(orient="index").
Creates a dictionary like this:
{
"data": {
"2024-01-01T00:00:00+01:00": 1,
"2024-01-02T00:00:00+01:00": 2,
"2024-01-03T00:00:00+01:00": 3,
...
},
"dtype": "float64",
"tz": "Europe/Berlin"
}
Load Measurement
The EOS measurement store provides for storing energy meter readings of loads.
The associated measurement keys can be configured by:
{
"measurement": {
"load_emr_keys": ["load0_emr", "my special load", ...]
}
}
Load measurements can be stored for any datetime. The values between different meter readings are linearly approximated. Storing values between optimization intervals is generally not useful.
The EOS measurement store automatically sums all given loads to create a total load value series
for specified intervals, usually one hour. This aggregated data can be used for load predictions.
An interval that the meters do not fully cover (before the first or after the last reading, a meter
reset, or a gap longer than the meter's gap limit) has no value instead of zero load; with
several load meters, all of them must cover it. The LoadAkkudoktorAdjusted provider skips hours
without a value.
Meter gaps
The energy between two readings of a *_emr_keys meter (load, grid import/export, PV production)
is spread evenly over the time between them. A gap longer than measurement.emr_max_gap_seconds
(default 10800 s, 3 hours) has no energy value instead: an outage of EOS or of the meter does not
turn into invented, even consumption or production, nights included.
{
"measurement": {
"emr_max_gap_seconds": 10800
}
}
Set it to null to spread every gap evenly (the behaviour before the limit). A feeder that only
sends a reading when the meter value changes (e.g. a PV or export meter that stands still at night)
needs null or a value longer than its longest still period; the Home Assistant adapter reads
the meters on every energy management run and needs no change.
A single meter can get its own limit with a channels entry, which takes precedence:
{
"measurement": {
"pv_production_emr_keys": ["pv1_emr"],
"channels": {
"pv1_emr": {
"quantity": "cumulative_energy",
"unit": "kWh",
"max_gap_seconds": 43200
}
}
}
}
The entry of a *_emr_keys meter must stay cumulative_energy in kWh.
:::{admonition} Warning
:class: warning
Only use actual meter readings in kWh, not energy consumption.
Example: 112345.77, 112389.23, 112412.55, …
:::
Grid Export/ Import Measurement
The EOS measurement store also allows for the storage of meter readings for grid import and export.
The associated measurement keys can be configured by:
{
"measurement": {
"grid_export_emr_keys": ["grid_export_emr", ...],
"grid_import_emr_keys": ["grid_import_emr", ...],
}
}
:::{admonition} Todo :class: note Currently not used. Integrate grid meter readings into the respective predictions. :::
Battery/ Electric Vehicle State of Charge (SoC) Measurement
The state of charge (SoC) measurement of batteries and electric vehicle batteries can be stored.
The associated measurement key is pre-defined by the device configuration. It can be
determined from the device configuration by the read-only measurement_key_soc_factor configuration
option.
Battery/ Electric Vehicle Power Measurement
The charge/ discharge power measurements of batteries and electric vehicle batteries can be stored. Charging power is denoted by a negative value, discharging power by a positive value.
The associated measurement keys are pre-defined by the device configuration. They can be
determined from the device configuration by read-only configuration options:
measurement_key_power_l1_wmeasurement_key_power_l2_wmeasurement_key_power_l3_wmeasurement_key_power_3_phase_sym_w