An inverter profile describes the technical data of an inverter model: its nominal AC power, the DC→AC and AC→DC efficiency curves over the load fraction (AC power relative to the nominal power), the AC charge power limit of the model, whether that limit also limits PV charging, and an optional power derating over the ambient temperature. Curves are read linearly and clamped at their ends, so every lookup yields a value. The packaged profile generic-hybrid has typical hybrid inverter efficiencies, no nominal power (the inverter device has to provide it) and full power up to 45 degC. Inverter settings name their profile (inverter_profile, default generic-hybrid) and hold the differences of the unit in profile_adjustment: nominal_power_w (replaces the profile value, required for a generic profile), max_power_w and max_ac_charge_power_w (installation limits that can only lower; an AC charge limit of 0 disables AC charging). The effective parameters are resolved at the ambient temperature of the inverter, given by the new measurement key <device_id>-temperature-degc (45 degC without a fresh value); the power derating lowers the maximum power and the AC charge limit. Optimization parameters are always valid: the GENETIC and GENETIC0 parameter preparation resolve the inverter with resolve_current_operating_parameters_or_defaults, which never raises. An unusable profile gives the generic-hybrid profile, a missing nominal power the fallback of 10000 W, an inverter derated to zero power the parameters at 45 degC, and no usable profile at all the profile adjustment with constant efficiency; each is logged as error. The GENETIC inverter takes the AC→DC efficiency curve of the profile, solved exactly on each linear piece of the curve (about 2 % longer runs); GENETIC0 keeps constant efficiencies and no longer replaces the configured inverters with the demo inverter; a battery, electric vehicle or inverter that cannot be prepared is left out of the GENETIC0 run, never replaced by a demo device. Configurations migrate: max_power_w becomes profile_adjustment.nominal_power_w, max_ac_charge_power_w moves into the adjustment, an ac_to_dc_efficiency of 0 keeps AC charging disabled, and the efficiency fields are dropped with an error log, as for batteries, so the profile efficiencies apply. Home Assistant config paths follow. Additional changes - Move the curve algorithms of the battery profile into profilecurve, so battery and inverter profiles share them; the battery profile keeps its document format and classes. - Move ProfileBaseModel, the strict base of profile documents, into profilestore. - Serve inverter profiles through the profile REST API. Refuse to delete a profile that a configured device uses and that has no packaged profile to revert to (409). - Share the measurement access of the device settings in devicemeasurement. - Rename check_battery_profiles to check_device_profiles; the device profile check at configuration setup covers inverters, too. - Document inverter profiles, their configuration, defaults and sharing; regenerate the configuration and OpenAPI documentation. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
24 KiB
% SPDX-License-Identifier: Apache-2.0
Automatic Optimization
Introduction
EOS offers two approaches to optimize your energy management system: post /optimize optimization and
automatic optimization.
The post /optimize optimization interface, based on a POST request to /optimize, is widely
used. It was originally developed by Andreas at the start of the project and is still demonstrated
in his instructional videos. This interface allows users or external systems to trigger an
optimization manually, supplying custom parameters and timing.
As an alternative, EOS supports automatic optimization, which runs automatically at configured
intervals. It retrieves all required input data — including electricity prices, battery storage
capacity, PV production forecasts, and temperature data — based on your system configuration.
Genetic Algorithm
Both optimization modes use the same core optimization engine.
EOS uses a genetic algorithm to find an optimal control strategy for home energy devices such as household loads, batteries, and electric vehicles.
In this context, each individual represents a possible solution — a specific control schedule that defines how devices should operate over time. These individuals are evaluated using resource simulations, which model the system’s energy behavior over a defined time period divided into fixed intervals.
The quality of each solution (its fitness) is determined by how well it performs during simulation, based on objectives such as minimizing electricity costs, maximizing self-consumption, or meeting battery charge targets.
Through an iterative process of selection, crossover, and mutation, the algorithm gradually evolves more effective solutions. The final result is an optimized control strategy that balances multiple system goals within the constraints of the input data and configuration.
:::{admonition} Note :class: note You don’t need to understand the internal workings of the genetic algorithm to benefit from automatic optimization. EOS handles everything behind the scenes based on your configuration. However, advanced users can fine-tune the optimization behavior using additional settings like population size, penalties, and random seed. :::
Energy Management Plan
Whenever the optimization is run, the energy management plan is updated. The energy management plan provides a list of energy management instructions in chronological order. The instructions lean on to the S2 standard to have maximum flexibility and stay completely independent from any manufacturer.
Battery Instructions
The battery control instructions assume an idealized battery model. Under this model, the battery can be operated in four discrete operation modes:
| Operation Mode ID | Description |
|---|---|
| IDLE | Battery neither charges nor discharges; holds its state of charge. |
| CHARGE | Charge at a specified power rate up to the allowable maximum. |
| DISCHARGE | Discharge at a specified power rate up to the allowable maximum. |
| ALLOW_DISCHARGE | Allow the battery to freely discharge depending on its instantaneous power setpoint. |
The operation mode factor (0.0–1.0) specifies the normalized power rate relative to the battery's nominal maximum charge or discharge power. A value of 1.0 corresponds to full-rate charging or discharging, while 0.0 indicates no power transfer. Intermediate values scale the power proportionally.
Electric Vehicle Instructions
The electric vehicle control instructions assume an idealized EV battery model. Under this model, the EV battery can be operated in two operation modes:
| Operation Mode ID | Description |
|---|---|
| IDLE | Battery neither charges nor discharges; holds its state of charge. |
| CHARGE | Charge at a specified power rate up to the allowable maximum. |
The operation mode factor (0.0–1.0) specifies the normalized power rate relative to the battery's nominal maximum charge power. A value of 1.0 corresponds to full-rate charging, while 0.0 indicates no power transfer. Intermediate values scale the power proportionally.
Home Appliance Instructions
The home appliance instructions assume an idealized home appliance model. Under this model, the home appliance can be operated in two operation modes:
| Operation Mode ID | Description |
|---|---|
| RUN | The home appliance is started and runs until the end of it's power sequence. |
| IDLE | The home appliance does not run. |
The operation mode factor (0.0–1.0) is ignored.
Configuration
Energy management configuration
The energy management is run on configured intervals with some startup delay after server start. Both values are given in seconds.
:::{admonition} Note
:class: note
If no interval is configured (None, null) there will be only one energy management run at
startup.
:::
The energy management can be run in three modes:
- OPTIMIZATION: A full optimization is done. This includes update of predictions.
- PREDICTION: Only the predictions are updated.
- DISABLED: No energy management is run.
Example:
{
"ems": {
"startup_delay": 5.0,
"interval": 300.0,
"mode": "OPTIMIZATION"
}
}
Optimization Configuration
Optimization Time Configuration
-
horizon_hours: The optimization horizon parameter defines the default time window — in hours — within which the energy optimization goal shall be achieved.
Specific devices, like the home appliance, have their own configuration for time windows. If the time windows are not configured the simulation uses the default time window.
Each device simulation run must ensure that all tasks or appliance cycles (e.g., running a dishwasher) are completed within the configured time windows.
-
interval: Defines the time step in seconds between control actions (e.g.
3600for one hour,900for 15 minutes).
:::{warning} Current Limitation
At present, the interval setting is not used by the genetic algorithm. Instead:
- The control interval is fixed to 1 hour.
Support for configurable intervals (e.g. 15-minute steps) may be added in a future release. :::
Genetic Algorithm Parameters
The behavior of the genetic algorithm can be customized using the following configuration options:
-
individuals (
int, default:300): Sets the number of individuals (candidate solutions) in the (first) generation. A higher number increases solution diversity and the chance of finding a good result, but also increases computation time. -
generations (
int, default:400): Sets the number of generations to evaluate the optimal solution. In each generation, solutions are evaluated and evolved. More generations can improve optimization quality but increase computation time. Best results are usually found within a moderate number of generations. -
seed (
intornull, default:null): Sets the random seed for reproducible results.-
If
null, a random seed is used (non-reproducible). -
If an integer is provided, it ensures that the same optimization input yields the same output.
A fixed seed to ensure reproducibility. Runs with the same seed and configuration will produce the same results.
-
-
fitness_cache_max_entries (
intornull, default:null): Limits the fitness cache of one optimization run. The cache remembers the fitness of every evaluated plan so that a repeated plan is not simulated again. It is cleared after each run, but during a run it grows with individuals × generations (roughly 100 MB at 300 × 400) while typically only 5–15 % of the evaluations hit it.- If
null, the cache is unbounded (previous behaviour). - If
0, the cache is disabled; every plan is simulated. - If a positive integer N, the cache holds at most N keys and drops the oldest first. Each evaluated plan takes one or two keys.
The value never changes the result: with a fixed seed, all settings give the same plan. Small devices (e.g. 512 MB RAM) should use
0or a few thousand; this costs a few percent of run time. - If
-
penalties (
dict): Defines how penalties are applied to solutions that violate constraints (e.g., undercharged batteries). Penalty function parameter values influence the fitness score, discouraging undesirable solutions.
:::{note} Supported Penalty Functions
-
ev_soc_miss: Applies a penalty when the state of charge (SOC) of the electric vehicle battery falls below the required minimum. This encourages the optimizer to ensure sufficient EV charging. Default:10. -
ac_charge_break_even: Applies a penalty for each scheduled AC grid-charging hour where the round-trip losses (AC→DC inverter, battery internal, DC→AC inverter) mean the stored energy can never be discharged at a price that recovers the charging cost. Energy already stored in the battery from PV generation is treated as free and covers the most expensive future hours first, so the penalty only fires for the hours that remain genuinely uncovered.A value of
1.0(default) means the penalty equals the actual economic loss in €. Use larger values (e.g.3.0) to make the optimizer more aggressively avoid unprofitable AC charging, or0.0to disable this penalty entirely. -
battery_full_charge_miss: Applies a penalty per percent the battery stays below its target when a periodic full charge is due and enforced (see Periodic full charge). Default:10. :::
Value Formats
-
Time-related values:
hours: specified in hours (e.g.24)interval: specified in seconds (e.g.3600)
-
Genetic algorithm parameters:
individuals: must be an integerseed: must be an integer ornullfor random behavior
-
Penalty function parameter values: may be
float,int, orstring, depending on the type of penalty function.
Optimization configuration example
{
"optimization": {
"hours": 24,
"interval": 3600,
"genetic" : {
"individuals": 300,
"generations": 400,
"seed": null,
"penalties": {
"ev_soc_miss": 10,
"ac_charge_break_even": 1.0
}
}
}
}
Device simulation configuration
The device simulations are used to evaluate the fitness of the individuals of the solution population.
The GENETIC algorithm supports 4 devices:
- inverter: A photovoltaic power inverter that can export to the grid and charge a battery. The inverter is mandatory.
- electric_vehicle: An electric vehicle, basically the battery of an electric vehicle. The The electrical vehicle is optional.
- battery: A battery that can be charged by the inverter. The battery is mandatory.
- home_appliance: A home appliance, like a washing machine or a dish washer. The home appliance is optional.
:::{admonition} Warning :class: warning The GENETIC algorithm can only use the first inverter, electrical vehicle, battery, home appliance that is configured, even if more devices are configured. :::
Inverter simulation configuration
Example:
{
"devices": {
"max_inverters": 1,
"inverters": {
"inv1": {
"inverter_profile": "generic-hybrid",
"profile_adjustment": {
"nominal_power_w": 10000,
"max_ac_charge_power_w": 5000
},
"battery_id": "bat1"
}
}
}
}
The technical data of the inverter comes from an inverter profile (see ): the efficiency curves for battery discharge (DC→AC) and for charging the battery from the grid (AC→DC), the AC charge power limit of the model and the power derating over the ambient temperature. The inverter settings select the profile and describe how the unit differs from it:
inverter_profile: Name of the inverter profile. Defaultgeneric-hybrid.profile_adjustment.nominal_power_w: Nominal AC power of the installed inverter [W]. Replaces the nominal power of the profile; required for a generic profile such asgeneric-hybrid.profile_adjustment.max_power_w: AC power limit of the installation [W], e.g. a configured output limit. Can only lower the (derated) nominal power. Defaultnull.profile_adjustment.max_ac_charge_power_w: AC charge power limit of the installation [W]. Can only lower the limit of the profile. Set to0to disable AC charging. Defaultnull.dc_to_ac_efficiency_reference_load_fraction: Load fraction of the maximum power at which the DC→AC efficiency curve is evaluated where stored energy is valued without a specific discharge, e.g. the energy left in the battery at the end of the horizon and the AC charge break-even. Choose the typical load the battery serves. Default0.06.
The efficiency curves are over the load fraction, the AC power relative to the nominal power. Real inverters are much less efficient at low load, e.g. when the battery serves a small night-time base load. The efficiency is always the one at the AC power of the conversion: if the battery limits a discharge (low state of charge or its power limit), the conversion is evaluated at that lower load, not at the requested one; charging from the grid draws the AC energy at the efficiency of the AC load actually drawn.
Power derating: inverters reduce their power when they get hot. EOS reads the ambient
temperature of the inverter from the measurement <device_id>-temperature-degc (e.g.
inv1-temperature-degc) at the start of each optimization and limits the maximum power and the
AC charge power by the derating of the profile at that temperature. Without a measurement in the
last hour EOS assumes 45 °C, where the generic-hybrid profile is not derated yet.
The resolved values are shown as read-only fields of the inverter configuration
(effective_nominal_power_w, effective_max_power_w, effective_max_ac_charge_power_w,
effective_dc_to_ac_efficiency, effective_ac_to_dc_efficiency), evaluated at 45 °C. If the
configured inverter profile does not exist or is invalid, the optimization uses generic-hybrid
with the profile adjustment instead and logs an error naming the inverter.
:::{admonition} Note
:class: note
Configurations of earlier versions are migrated automatically. max_power_w becomes
profile_adjustment.nominal_power_w and max_ac_charge_power_w moves into the profile
adjustment; an ac_to_dc_efficiency of 0 keeps AC charging disabled. The former fields
ac_to_dc_efficiency, dc_to_ac_efficiency, dc_to_ac_efficiency_curve and
ac_charge_limits_total_charge come from the inverter profile now and are dropped (logged as
error), so the efficiencies of the profile apply instead of the former default 1.0 (lossless).
To keep other values, save an own inverter profile and select it.
:::
Electric vehicle simulation configuration
Example:
{
"devices": {
"max_electric_vehicles": 1,
"electric_vehicles": {
"ev1": {
"device_id": "ev1",
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 50000,
"max_charge_power_w": 10000
},
"charge_rates": [0.0, 0.25, 0.5, 0.75, 1.0],
"min_soc_percentage": 10,
"max_soc_percentage": 80
}
}
},
"measurement": {
"electric_vehicle_soc_keys": ["ev1_soc"]
}
}
Battery simulation configuration
Example:
{
"devices": {
"max_batteries": 1,
"batteries": {
"battery1": {
"device_id": "battery1",
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 8000,
"max_charge_power_w": 8000
},
"levelized_cost_of_storage_amt_kwh": 0.12,
"min_charge_power_w": 50,
"charge_rates": null,
"min_soc_percentage": 5,
"max_soc_percentage": 95
}
}
}
}
Periodic full charge
LFP batteries have an almost flat voltage curve in the middle of their range. The battery management system can only recalibrate the state of charge close to full charge, so many manufacturers expect a full charge every few weeks, and some batteries start one on their own at an arbitrary time. A periodic full charge lets EOS plan it instead, preferably from PV surplus or at a cheap price.
The feature is off by default (GENETIC only). The interval and the detection threshold are
properties of the battery model and come from the battery profile; the profile_adjustment of a
stationary battery replaces them for this unit. The target and the use of the grid are battery
settings:
full_charge_interval_days(battery profile orprofile_adjustment): maximum number of days between two full charges.nulldisables the feature; the bundledgeneric-lfpprofile sets none. For LFP batteries 21 to 25 days are a reasonable start; check what the manufacturer requires.full_charge_detect_percentage(battery profile orprofile_adjustment, profile default99): the measured state of charge from which the battery counts as full. Many battery management systems never report exactly 100 %.full_charge_soc_percentage(default100): the target. It may be abovemax_soc_percentage, which keeps applying on all other days, but is capped by the technical maximum SoC of the battery profile.full_charge_allow_grid(defaultfalse): withfalse, EOS only raises the maximum state of charge while the full charge is due, so that PV surplus can fill the battery; the target is not enforced. Withtrue, the optimizer has to reach the target and charges from the grid if needed, at the cheapest time before the deadline.
The effective values are available as effective_full_charge_interval_days and
effective_full_charge_detect_percentage. The cell chemistry is the chemistry of the battery
profile.
The last full charge is taken from the measured state of charge of the battery
(<device_id>-soc-factor), so a full charge from PV or one the battery started itself counts as
well. Nothing else is stored. Without a full charge in the last interval, the interval counts
from the oldest measurement, so a new installation is not forced into a full charge on its first
day. The next full charge is due one interval after the last one. EOS acts once that deadline
falls within the optimization horizon or has passed, and logs an INFO message for every run in
which the full charge is due. The optimizer always gets at least 24 hours to finish it, so that
a close or overdue full charge can still use the cheapest time.
{
"devices": {
"batteries": {
"battery1": {
"device_id": "battery1",
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 10000,
"full_charge_interval_days": 21
},
"max_soc_percentage": 90,
"full_charge_allow_grid": true
}
}
}
}
Home appliance simulation configuration
Example:
{
"devices": {
"max_home_appliances": 1,
"home_appliances": [
{
"device_id": "washing machine",
"consumption_wh": 600,
"duration_h": 3,
"time_windows": null,
}
]
}
}
The time windows the home appliance may run can be configured in several ways. See the time window configuration for details.
Predictions configuration
The device simulation may rely on predictions to simulate proper behaviour. E.g. the inverter needs to know the PV forecast.
Configure the predictions as described on the prediction page.
Providing your own prediction data
If EOS does not have a suitable prediction provider you can provide your own data for a prediction. Configure the respective import provider (ElecPriceImport, LoadImport, PVForecastImport, WeatherImport) and use one of the following endpoints to provide your own data:
- PUT
/v1/prediction/import/ElecPriceImport - PUT
/v1/prediction/import/LoadImport - PUT
/v1/prediction/import/PVForecastImport - PUT
/v1/prediction/import/WeatherImport
Measurement configuration
Predictions and device simulations often rely on measurement data to produce accurate results. For example:
- A load forecast requires past energy meter readings.
- A battery simulation needs the current state of charge (SoC) to start from the correct condition.
Before using these features, make sure to configure the measurement as described on the measurement page.
Providing your own measurement data
You can provide your own measurement data to the prediction and simulation engine through the following REST endpoints (see the measurement page for details on the data format):
- PUT
/v1/measurement/data - PUT
/v1/measurement/dataframe - PUT
/v1/measurement/series - PUT
/v1/measurement/value
Example: Supplying Battery and EV SoC
For batteries and electric vehicles, it is strongly recommended to provide current SoC. This ensures that simulations start with the correct state.
The simplest way is to use the /v1/measurement/value endpoint.
Assuming the battery is named battery1 and the EV is named ev11:
-
Use the measurement keys that are pre-configured for your devices. For example:
{ "devices": { "batteries": { "battery1": { "device_id": "battery1", "profile_adjustment": {"nominal_capacity_wh": 8000}, ... "measurement_key_soc_factor": "battery1-soc-factor", ... } }, "electric_vehicles": { "ev11": { "device_id": "ev11", "profile_adjustment": {"nominal_capacity_wh": 8000}, ... "measurement_key_soc_factor": "ev11-soc-factor", ... } } } } -
Record your SoC readings to these keys.
- Enter the values as factor of total capacity of the respective battery.
In these examples:
- datetime specifies the timestamp of the measurement.
- key is the measurement key (e.g. battery1-soc-factor).
- value is the numeric measurement value (e.g. SoC as factor of total capacity).
Raw HTTP request
PUT http://127.0.0.1:8503/v1/measurement/value?datetime=2025-09-26T16%3A39&key=battery1-soc-factor&value=0.57
PUT http://127.0.0.1:8503/v1/measurement/value?datetime=2025-09-26T16%3A39&key=ev11-soc-factor&value=0.22
Equivalent curl commands
curl -X PUT "http://127.0.0.1:8503/v1/measurement/value?datetime=2025-09-26T16%3A39&key=battery1-soc-factor&value=0.57"
curl -X PUT "http://127.0.0.1:8503/v1/measurement/value?datetime=2025-09-26T16%3A39&key=ev11-soc-factor&value=0.22"
Example: Supplying Load Data
To provide your actual load measurements in Akkudoktor-EOS:
-
Configure the measurement keys for your load energy meters. For example:
{ "measurements": { "load_emr_keys": ["my_load_meter_reading", "my_other_load_meter_reading"] } } -
Record your meter readings to these keys.
- Enter the values exactly as your energy meters report them, in kWh.
- Use the same approach as when supplying battery or EV SoC data.