mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 15:06:20 +01:00
A re-plan treated a running home appliance as not started. In its start slot it could pick another start of equal cost and switch the appliance off; after the start slot it could only plan a new complete run later; and when no complete run fitted into the rest of the window, the DAILY cycle was dropped and the running appliance got OFF. The executor now reports the start of a planned run as UNIX seconds under `<device_id>.run_started_at` (setting `run_started_measurement_key`) and 0 when the device reports the run as finished. The device decides when that is, also before or after the configured duration. Until then the GENETIC optimizer places the remaining energy from now on as fixed load, independent of windows, deadline and genes, sends RUN, counts the run as a cycle of its start day and plans further cycles after its end and gap. A run past its duration keeps the current slot without extra energy; a start more than two run durations ago, or an invalid value, is logged and ignored. Refs: #1548 Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com> Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
14 KiB
14 KiB
Configuration for all controllable devices in the simulation
Every device collection is a dict[str, <Settings>] keyed by
device_id. This makes config paths stable regardless of
declaration order and lets each device settings class build its own
config path from self.device_id without needing an external index.
:::{table} devices :widths: 10 20 10 5 5 30 :align: left
| Name | Environment Variable | Type | Read-Only | Default | Description |
|---|---|---|---|---|---|
| batteries | EOS_DEVICES__BATTERIES |
Optional[dict[str, akkudoktoreos.devices.settings.batterysettings.BatteriesCommonSettings]] |
rw |
None |
Stationary battery storage devices, keyed by device_id. |
| electric_vehicles | EOS_DEVICES__ELECTRIC_VEHICLES |
Optional[dict[str, akkudoktoreos.devices.settings.batterysettings.BatteriesCommonSettings]] |
rw |
None |
Electric vehicle battery packs, keyed by device_id. |
| home_appliances | EOS_DEVICES__HOME_APPLIANCES |
dict[str, akkudoktoreos.devices.settings.homeappliancesettings.HomeApplianceCommonSettings] |
rw |
required |
Shiftable home appliance devices, keyed by device_id. |
| inverters | EOS_DEVICES__INVERTERS |
Optional[dict[str, akkudoktoreos.devices.settings.invertersettings.InverterCommonSettings]] |
rw |
None |
Inverter devices, keyed by device_id. |
| max_batteries | EOS_DEVICES__MAX_BATTERIES |
Optional[int] |
rw |
None |
Maximum number of batteries allowed. |
| max_electric_vehicles | EOS_DEVICES__MAX_ELECTRIC_VEHICLES |
Optional[int] |
rw |
None |
Maximum number of EVs allowed. |
| max_home_appliances | EOS_DEVICES__MAX_HOME_APPLIANCES |
Optional[int] |
rw |
None |
Maximum number of home appliances allowed. |
| max_inverters | EOS_DEVICES__MAX_INVERTERS |
Optional[int] |
rw |
None |
Maximum number of inverters allowed. |
| measurement_keys | list[str] |
ro |
N/A |
All measurement keys across all configured devices. | |
| ::: |
Example Input
{
"devices": {
"batteries": {
"bat0": {
"device_id": "bat0",
"capacity_estimation": null,
"capacity_estimate": null,
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 8000,
"max_charge_power_w": null,
"max_discharge_power_w": null,
"full_charge_interval_days": null,
"full_charge_detect_percentage": null
},
"levelized_cost_of_storage_amt_kwh": 0.0,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"grid_export_rates": [
0.25,
0.5,
0.75,
1.0
],
"min_soc_deadline_datetime": null,
"min_soc_max_duration_h": null,
"full_charge_soc_percentage": 100,
"full_charge_allow_grid": false
}
},
"max_batteries": 1,
"electric_vehicles": {
"ev0": {
"device_id": "ev0",
"capacity_estimation": null,
"capacity_estimate": null,
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 60000,
"max_charge_power_w": null,
"max_discharge_power_w": null,
"full_charge_interval_days": null,
"full_charge_detect_percentage": null
},
"levelized_cost_of_storage_amt_kwh": 0.0,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"grid_export_rates": [
0.25,
0.5,
0.75,
1.0
],
"min_soc_deadline_datetime": null,
"min_soc_max_duration_h": null,
"full_charge_soc_percentage": 100,
"full_charge_allow_grid": false
}
},
"max_electric_vehicles": 1,
"inverters": {},
"max_inverters": 1,
"home_appliances": {
"dishwasher": {
"device_id": "dishwasher",
"consumption_wh": 1500,
"duration_h": 2,
"num_cycles": 1,
"cycle_time_windows": null,
"min_cycle_gap_h": 0,
"cycles_completed_measurement_key": null,
"run_started_measurement_key": null,
"load_profile_power_w": null,
"load_profile_interval_seconds": null,
"schedule_mode": "ONCE",
"time_windows": null,
"earliest_start_datetime": null,
"deadline_datetime": null,
"deadline_policy": "BEST_EFFORT"
}
},
"max_home_appliances": 3
}
}
Example Output
{
"devices": {
"batteries": {
"bat0": {
"device_id": "bat0",
"capacity_estimation": null,
"capacity_estimate": null,
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 8000,
"max_charge_power_w": null,
"max_discharge_power_w": null,
"full_charge_interval_days": null,
"full_charge_detect_percentage": null
},
"levelized_cost_of_storage_amt_kwh": 0.0,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"grid_export_rates": [
0.25,
0.5,
0.75,
1.0
],
"min_soc_deadline_datetime": null,
"min_soc_max_duration_h": null,
"full_charge_soc_percentage": 100,
"full_charge_allow_grid": false,
"effective_nominal_capacity_wh": 8000,
"effective_max_charge_power_w": 5000.0,
"effective_max_discharge_power_w": 4000.0,
"effective_charging_efficiency": 0.955,
"effective_discharging_efficiency": 0.96,
"effective_min_soc_percentage": 0,
"effective_max_soc_percentage": 100,
"effective_full_charge_interval_days": null,
"effective_full_charge_detect_percentage": 99,
"measurement_key_soc_factor": "bat0-soc-factor",
"measurement_key_temperature_degc": "bat0-temperature-degc",
"measurement_key_charge_power_w": "bat0-charge-power-w",
"measurement_key_discharge_power_w": "bat0-discharge-power-w",
"measurement_key_power_l1_w": "bat0-power-l1-w",
"measurement_key_power_l2_w": "bat0-power-l2-w",
"measurement_key_power_l3_w": "bat0-power-l3-w",
"measurement_key_power_3_phase_sym_w": "bat0-power-3-phase-sym-w",
"measurement_keys": [
"bat0-soc-factor",
"bat0-temperature-degc",
"bat0-charge-power-w",
"bat0-discharge-power-w",
"bat0-power-l1-w",
"bat0-power-l2-w",
"bat0-power-l3-w",
"bat0-power-3-phase-sym-w"
]
}
},
"max_batteries": 1,
"electric_vehicles": {
"ev0": {
"device_id": "ev0",
"capacity_estimation": null,
"capacity_estimate": null,
"battery_profile": "generic-lfp",
"profile_adjustment": {
"nominal_capacity_wh": 60000,
"max_charge_power_w": null,
"max_discharge_power_w": null,
"full_charge_interval_days": null,
"full_charge_detect_percentage": null
},
"levelized_cost_of_storage_amt_kwh": 0.0,
"min_charge_power_w": 50,
"charge_rates": [
0.0,
0.1,
0.2,
0.3,
0.4,
0.5,
0.6,
0.7,
0.8,
0.9,
1.0
],
"min_soc_percentage": 0,
"max_soc_percentage": 100,
"grid_export_rates": [
0.25,
0.5,
0.75,
1.0
],
"min_soc_deadline_datetime": null,
"min_soc_max_duration_h": null,
"full_charge_soc_percentage": 100,
"full_charge_allow_grid": false,
"effective_nominal_capacity_wh": 60000,
"effective_max_charge_power_w": 5000.0,
"effective_max_discharge_power_w": 5000.0,
"effective_charging_efficiency": 0.975,
"effective_discharging_efficiency": 0.975,
"effective_min_soc_percentage": 0,
"effective_max_soc_percentage": 100,
"effective_full_charge_interval_days": null,
"effective_full_charge_detect_percentage": 99,
"measurement_key_soc_factor": "ev0-soc-factor",
"measurement_key_temperature_degc": "ev0-temperature-degc",
"measurement_key_charge_power_w": "ev0-charge-power-w",
"measurement_key_discharge_power_w": "ev0-discharge-power-w",
"measurement_key_power_l1_w": "ev0-power-l1-w",
"measurement_key_power_l2_w": "ev0-power-l2-w",
"measurement_key_power_l3_w": "ev0-power-l3-w",
"measurement_key_power_3_phase_sym_w": "ev0-power-3-phase-sym-w",
"measurement_keys": [
"ev0-soc-factor",
"ev0-temperature-degc",
"ev0-charge-power-w",
"ev0-discharge-power-w",
"ev0-power-l1-w",
"ev0-power-l2-w",
"ev0-power-l3-w",
"ev0-power-3-phase-sym-w"
]
}
},
"max_electric_vehicles": 1,
"inverters": {},
"max_inverters": 1,
"home_appliances": {
"dishwasher": {
"device_id": "dishwasher",
"consumption_wh": 1500,
"duration_h": 2,
"num_cycles": 1,
"cycle_time_windows": null,
"min_cycle_gap_h": 0,
"cycles_completed_measurement_key": null,
"run_started_measurement_key": null,
"load_profile_power_w": null,
"load_profile_interval_seconds": null,
"schedule_mode": "ONCE",
"time_windows": null,
"earliest_start_datetime": null,
"deadline_datetime": null,
"deadline_policy": "BEST_EFFORT",
"effective_num_cycles": 1,
"measurement_keys": [
"dishwasher.cycles_completed",
"dishwasher.run_started_at"
]
}
},
"max_home_appliances": 3,
"measurement_keys": [
"bat0-soc-factor",
"bat0-temperature-degc",
"bat0-charge-power-w",
"bat0-discharge-power-w",
"bat0-power-l1-w",
"bat0-power-l2-w",
"bat0-power-l3-w",
"bat0-power-3-phase-sym-w",
"ev0-soc-factor",
"ev0-temperature-degc",
"ev0-charge-power-w",
"ev0-discharge-power-w",
"ev0-power-l1-w",
"ev0-power-l2-w",
"ev0-power-l3-w",
"ev0-power-3-phase-sym-w",
"dishwasher.cycles_completed",
"dishwasher.run_started_at"
]
}
}