A re-plan treated a running home appliance as not started. In its start slot it could pick another start of equal cost and switch the appliance off; after the start slot it could only plan a new complete run later; and when no complete run fitted into the rest of the window, the DAILY cycle was dropped and the running appliance got OFF. The executor now reports the start of a planned run as UNIX seconds under `<device_id>.run_started_at` (setting `run_started_measurement_key`) and 0 when the device reports the run as finished. The device decides when that is, also before or after the configured duration. Until then the GENETIC optimizer places the remaining energy from now on as fixed load, independent of windows, deadline and genes, sends RUN, counts the run as a cycle of its start day and plans further cycles after its end and gap. A run past its duration keeps the current slot without extra energy; a start more than two run durations ago, or an invalid value, is logged and ignored. Refs: #1548 Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com> Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Assisted-by: Claude Code (claude-opus-5-5)
4.8 KiB
GENETIC configuration and manual acceptance
Apply the dependencies in review handoff before the complete GENETIC PR. These changes implement the feature branch on current EOS interfaces; they do not migrate a running Home Assistant installation automatically.
Configuration
Hardware and schedules belong in the typed devices maps, keyed by stable device
IDs. Configure an inverter and link its battery_id to the configured stationary
battery, or leave it empty when there is no battery. GENETIC currently supports one
inverter, one stationary battery, one EV and multiple household appliances. Explicit
validation rejects unsupported device counts and inconsistent links.
Example optimization settings (merge into an otherwise complete configuration):
{
"optimization": {
"algorithm": "GENETIC",
"genetic": {
"interval_sec": 900,
"horizon_hours": 24,
"tail_horizon_hours": 48,
"terminal_value_mode": "AUTO",
"measurement_max_age_seconds": 300
}
}
}
Use interval_sec: 3600 for hourly operation. AUTO evaluates available forecast
continuation; FIXED uses terminal_value_euro_per_kwh. Battery wear/LCOS remains a
separate cost. The tail affects scoring, never the emitted control horizon.
prediction.hours must cover the control horizon; shorter available tails are
clipped with diagnostics. Missing control forecasts cancel the run.
Old feature settings such as optimization.interval and flat terminal-value fields
migrate into optimization.genetic; explicit nested settings win. Check the saved
configuration after migration. GENETIC0 retains its separate settings and /optimize API.
Automatic GENETIC runs use the site's timezone derived from its coordinates, even when the server runs in UTC. An explicitly supplied run start retains its timezone. Stored results and warmstarts retain explicit timezones and absolute instants.
Requests and measurements
POST /v1/optimize runs GENETIC from configuration. An empty JSON object uses the
configured forecasts and fresh measurements. Runtime input may contain soc,
forecasts, start_solution and start_solution_datetime. Hardware overrides in
this body and query-string overrides are rejected. For example, with a configured
device ID storage:
{"soc": {"storage": 42}}
Request SoC values are integer percentages. Without an override, the measurement
key <device_id>-soc-factor must contain a recent factor from 0 to 1. Invalid,
future or stale measurements never become an assumed zero SoC. Completed appliance
cycles use their configured measurement key, default <device_id>.cycles_completed.
The start of a run in progress (UNIX seconds, 0 when finished) uses
<device_id>.run_started_at; such a run is kept until the device reports it finished.
Optional forecast arrays begin at local midnight, with one value per configured
slot: pv_forecast_wh and total_load are Wh per slot; electricity_price_per_wh
and feed_in_tariff_per_wh are currency per Wh. Provider PV/load power in W is
converted by the resolver. Supplied/imported sale tariffs are never replaced by
purchase prices. Missing optional arrays come from the selected providers.
Successful requests return the native result for that run. A failed run returns an error and cannot masquerade as a cached success. Generic solutions, plans and reports are derived from the same stored result. Warmstarts retain their source time so a later run shifts the previous controls to the new slot origin.
Retrieve the new GENETIC report with
GET /v1/energy-management/optimization/solution/GENETIC/pdf. It renders the stored
snapshot on demand; a missing result returns 404. The legacy PDF URL remains unchanged.
Manual acceptance after merge
- Back up the running configuration and update all merged EOS packages together.
- Confirm device IDs, inverter linkage, capacities, efficiencies, import/export limits, tariff units and the battery-export setting against your actual hardware.
- Check fresh SoC measurements and forecast coverage, then run Optimize at 60 and 15 minutes. Inspect timestamps, slot energies, native/generic results and the PDF.
- Compare AUTO and FIXED terminal value with identical inputs. Tail diagnostics must not appear as extra commands; sale prices must retain their configured signs.
- Exercise an EV departure and a flexible consumer schedule, including a completed cycle. Check permitted windows, required energy and device commands in your setup.
- Make a measurement stale or omit control forecast coverage and confirm the request fails explicitly. Verify the legacy GENETIC0 endpoint if your installation uses it.
Automated checks cover modeled behavior. The final manual test validates the actual HA entities, provider data and physical installation.