An inverter profile describes the technical data of an inverter model: its
nominal AC power, the DC→AC and AC→DC efficiency curves over the load
fraction (AC power relative to the nominal power), the AC charge power
limit of the model, whether that limit also limits PV charging, and an
optional power derating over the ambient temperature. Curves are read
linearly and clamped at their ends, so every lookup yields a value. The
packaged profile generic-hybrid has typical hybrid inverter efficiencies,
no nominal power (the inverter device has to provide it) and full power up
to 45 degC.

Inverter settings name their profile (inverter_profile, default
generic-hybrid) and hold the differences of the unit in profile_adjustment:
nominal_power_w (replaces the profile value, required for a generic
profile), max_power_w and max_ac_charge_power_w (installation limits that
can only lower; an AC charge limit of 0 disables AC charging). The
effective parameters are resolved at the ambient temperature of the
inverter, given by the new measurement key <device_id>-temperature-degc
(45 degC without a fresh value); the power derating lowers the maximum
power and the AC charge limit.

Optimization parameters are always valid: the GENETIC and GENETIC0
parameter preparation resolve the inverter with
resolve_current_operating_parameters_or_defaults, which never raises. An
unusable profile gives the generic-hybrid profile, a missing nominal power
the fallback of 10000 W, an inverter derated to zero power the parameters
at 45 degC, and no usable profile at all the profile adjustment with
constant efficiency; each is logged as error. The GENETIC inverter takes
the AC→DC efficiency curve of the profile, solved exactly on each linear
piece of the curve (about 2 % longer runs); GENETIC0 keeps constant
efficiencies and no longer replaces the configured inverters with the demo
inverter; a battery, electric vehicle or inverter that cannot be prepared
is left out of the GENETIC0 run, never replaced by a demo device.

Configurations migrate: max_power_w becomes
profile_adjustment.nominal_power_w, max_ac_charge_power_w moves into the
adjustment, an ac_to_dc_efficiency of 0 keeps AC charging disabled, and
the efficiency fields are dropped with an error log, as for batteries, so
the profile efficiencies apply. Home Assistant config paths follow.

Additional changes
- Move the curve algorithms of the battery profile into profilecurve, so
  battery and inverter profiles share them; the battery profile keeps its
  document format and classes.
- Move ProfileBaseModel, the strict base of profile documents, into
  profilestore.
- Serve inverter profiles through the profile REST API. Refuse to delete a
  profile that a configured device uses and that has no packaged profile
  to revert to (409).
- Share the measurement access of the device settings in
  devicemeasurement.
- Rename check_battery_profiles to check_device_profiles; the device
  profile check at configuration setup covers inverters, too.
- Document inverter profiles, their configuration, defaults and sharing;
  regenerate the configuration and OpenAPI documentation.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
2026-11-11 22:08:18 +01:00

43 lines
1.6 KiB
Python

"""Reading device measurements for the device settings.
Measurement access is asynchronous (``DataSequence.key_to_value``), so it is
kept out of the device settings models and out of the parameter resolution.
``get_measured_value`` is the only place where device settings talk to the
measurement subsystem; the device specific modules (e.g. ``batterymeasurement``,
``invertermeasurement``) turn the measured values into operating points.
"""
from typing import Optional
from loguru import logger
from akkudoktoreos.utils.datetimeutil import DateTime, to_duration
# Maximum age of a measurement that is still taken as "current".
DEVICE_MEASUREMENT_MAX_AGE: str = "1 hour"
async def get_measured_value(key: str, target_datetime: DateTime) -> Optional[float]:
"""Return the measured value for a measurement key nearest to a datetime.
Args:
key: Measurement key.
target_datetime: Datetime the value is looked up for.
Returns:
The value nearest to target_datetime within DEVICE_MEASUREMENT_MAX_AGE,
or None if there is no such value or the measurement cannot be queried.
"""
try:
from akkudoktoreos.core.coreabc import get_measurement
value = await get_measurement().key_to_value(
key=key,
target_datetime=target_datetime,
time_window=to_duration(DEVICE_MEASUREMENT_MAX_AGE),
)
return None if value is None else float(value)
except Exception as exc: # a missing measurement falls back to the defaults
logger.warning(f"Device measurement '{key}' not available: {exc}")
return None