@@ -1549,20 +1549,49 @@ def get_ipmi_power():
}
def get_ups_info():
"""Get UPS information from NUT (upsc)"""
ups_data = {}
"""Get UPS information from NUT (upsc) - supports both local and remote UPS"""
ups_list = []
try:
# First, list available UPS devices
upsmon_conf = '/etc/nut/upsmon.conf'
configured_ups = []
if os.path.exists(upsmon_conf):
try:
with open(upsmon_conf, 'r') as f:
for line in f:
line = line.strip()
# Look for MONITOR lines: MONITOR ups@hostname powervalue username password ("master"|"slave")
if line.startswith('MONITOR') and not line.startswith('#'):
parts = line.split()
if len(parts) >= 2:
ups_identifier = parts[1] # Format: upsname@hostname or just upsname
configured_ups.append(ups_identifier)
print(f"[v0] Found configured UPS in upsmon.conf: {ups_identifier}")
except Exception as e:
print(f"[v0] Error reading upsmon.conf: {e}")
result = subprocess.run(['upsc', '-l'], capture_output=True, text=True, timeout=5)
local_ups = []
if result.returncode == 0:
ups_list = result.stdout.strip().split('\n')
if ups_list and ups_list[0]:
ups_name = ups_list[0]
print(f"[v0] Found UPS: {ups_name}")
local_ups = [ups.strip() for ups in result.stdout.strip().split('\n') if ups.strip()]
print(f"[v0] Found local UPS devices: {local_ups}")
all_ups = list(set(configured_ups + local_ups))
if not all_ups:
print("[v0] No UPS devices found")
return {}
for ups_identifier in all_ups:
try:
ups_data = {
'name': ups_identifier,
'raw_data': {} # Store all raw data for the modal
}
# Get detailed UPS info
result = subprocess.run(['upsc', ups_name], capture_output=True, text=True, timeout=5)
result = subprocess.run(['upsc', ups_identifier], capture_output=True, text=True, timeout=5)
if result.returncode == 0:
for line in result.stdout.split('\n'):
if ':' in line:
@@ -1570,69 +1599,108 @@ def get_ups_info():
key = key.strip()
value = value.strip()
# Map common UPS variables
# Store all raw data
ups_data['raw_data'][key] = value
# Map common UPS variables for quick access
if key == 'device.model':
ups_data['model'] = value
elif key == 'device.mfr':
ups_data['manufacturer'] = value
elif key == 'device.serial':
ups_data['serial'] = value
elif key == 'device.type':
ups_data['device_type'] = value
elif key == 'ups.status':
ups_data['status'] = value
elif key == 'battery.charge':
ups_data['battery_charge'] = f"{value}%"
ups_data['battery_charge_value'] = float(value)
elif key == 'battery.charge.low':
ups_data['battery_charge_low'] = f"{value}%"
elif key == 'battery.runtime':
# Convert seconds to minutes
try:
runtime_sec = int(value)
runtime_min = runtime_sec // 60
ups_data['time_left'] = f"{runtime_min} minutes"
ups_data['time_left_seconds'] = runtime_sec
except ValueError:
ups_data['time_left'] = value
elif key == 'battery.runtime.low':
try:
runtime_sec = int(value)
runtime_min = runtime_sec // 60
ups_data['battery_runtime_low'] = f"{runtime_min} minutes"
except ValueError:
ups_data['battery_runtime_low'] = value
elif key == 'battery.voltage':
ups_data['battery_voltage'] = f"{value}V"
elif key == 'battery.voltage.nominal':
ups_data['battery_voltage_nominal'] = f"{value}V"
elif key == 'battery.type':
ups_data['battery_type'] = value
elif key == 'ups.load':
ups_data['load_percent'] = f"{value}%"
elif key == 'input.voltage':
ups_data['line_voltage'] = f"{value}V"
ups_data['load_value'] = float(value)
elif key == 'ups.realpower':
ups_data['real_power'] = f"{value}W"
elif key == 'ups.realpower.nominal':
ups_data['real_power_nominal'] = f"{value}W"
elif key == 'ups.power':
ups_data['apparent_power'] = f"{value}VA"
elif key == 'ups.power.nominal':
ups_data['apparent_power_nominal'] = f"{value}VA"
elif key == 'input.voltage':
ups_data['input_voltage'] = f"{value}V"
elif key == 'input.voltage.nominal':
ups_data['input_voltage_nominal'] = f"{value}V"
elif key == 'input.frequency':
ups_data['input_frequency'] = f"{value}Hz"
elif key == 'output.voltage':
ups_data['output_voltage'] = f"{value}V"
elif key == 'output.voltage.nominal':
ups_data['output_voltage_nominal'] = f"{value}V"
elif key == 'output.frequency':
ups_data['output_frequency'] = f"{value}Hz"
elif key == 'ups.beeper.status':
ups_data['beeper_status'] = value
elif key == 'ups.delay.shutdown':
ups_data['delay_shutdown'] = f"{value}s"
elif key == 'ups.delay.start':
ups_data['delay_start'] = f"{value}s"
elif key == 'ups.test.result':
ups_data['test_result'] = value
elif key == 'ups.firmware':
ups_data['firmware'] = value
elif key == 'driver.name':
ups_data['driver_name'] = value
elif key == 'driver.version':
ups_data['driver_version'] = value
print(f"[v0] UPS data: {ups_data}")
ups_list.append(ups_data)
print(f"[v0] Successfully retrieved data for UPS: {ups_identifier}")
else:
print(f"[v0] Failed to get data for UPS: {ups_identifier}")
except Exception as e:
print(f"[v0] Error getting info for UPS {ups_identifier}: {e}")
if len(ups_list) == 0:
return {}
elif len(ups_list) == 1:
return ups_list[0]
else:
return {'ups_list': ups_list, 'count': len(ups_list)}
except FileNotFoundError:
print("[v0] upsc not found")
print("[v0] upsc not found - NUT client not installed")
except Exception as e:
print(f"[v0] Error getting UPS info: {e}")
import traceback
traceback.print_exc()
return ups_data
def identify_temperature_sensor(sensor_name, adapter):
"""Identify what a temperature sensor corresponds to"""
sensor_lower = sensor_name.lower()
adapter_lower = adapter.lower() if adapter else ""
# CPU/Package temperatures
if "package" in sensor_lower or "tctl" in sensor_lower or "tccd" in sensor_lower:
return "CPU Package"
if "core" in sensor_lower:
core_num = re.search(r'(\d+)', sensor_name)
return f"CPU Core {core_num.group(1)}" if core_num else "CPU Core"
# Motherboard/Chipset
if "temp1" in sensor_lower and ("isa" in adapter_lower or "acpi" in adapter_lower):
return "Motherboard/Chipset"
if "pch" in sensor_lower or "chipset" in sensor_lower:
return "Chipset"
# Storage (NVMe, SATA)
if "nvme" in sensor_lower or "composite" in sensor_lower:
return "NVMe SSD"
if "sata" in sensor_lower or "ata" in sensor_lower:
return "SATA Drive"
# GPU
if any(gpu in adapter_lower for gpu in ["nouveau", "amdgpu", "radeon", "i915"]):
return "GPU"
# Network adapters
if "pci" in adapter_lower and "temp" in sensor_lower:
return "PCI Device"
return sensor_name
return {}
def get_temperature_info():
"""Get detailed temperature information from sensors command"""
@@ -4197,27 +4265,22 @@ def api_prometheus():
if ups.get('battery_charge') is not None:
metrics.append(f'# HELP proxmox_ups_battery_charge_percent UPS battery charge percentage')
metrics.append(f'# TYPE proxmox_ups_battery_charge_percent gauge')
metrics.append(f'proxmox_ups_battery_charge_percent{{node="{node}",ups="{ups_name}"}} {ups["battery_charge"]} {timestamp}')
metrics.append(f'proxmox_ups_battery_charge_percent{{node="{node}",ups="{ups_name}"}} {ups["battery_charge_value"]} {timestamp}') # Use numeric value
if ups.get('load_percent') is not None: # Changed from 'load' to 'load_percent'
metrics.append(f'# HELP proxmox_ups_load_percent UPS load percentage')
metrics.append(f'# TYPE proxmox_ups_load_percent gauge')
metrics.append(f'proxmox_ups_load_percent{{node="{node}",ups="{ups_name}"}} {ups["load_percent"]} {timestamp}')
metrics.append(f'proxmox_ups_load_percent{{node="{node}",ups="{ups_name}"}} {ups["load_value"]} {timestamp}') # Use numeric value
if ups.get('time_left'):
# Convert runtime to seconds
runtime_str = ups['time_left']
runtime_seconds = 0
if 'minutes' in runtime_str:
runtime_seconds = int(runtime_str.split()[0]) * 60
if ups.get('time_left_seconds') is not None:
metrics.append(f'# HELP proxmox_ups_runtime_seconds UPS runtime in seconds')
metrics.append(f'# TYPE proxmox_ups_runtime_seconds gauge')
metrics.append(f'proxmox_ups_runtime_seconds{{node="{node}",ups="{ups_name}"}} {runtime_seconds} {timestamp}')
metrics.append(f'proxmox_ups_runtime_seconds{{node="{node}",ups="{ups_name}"}} {ups["time_left_seconds"]} {timestamp}')
if ups.get('line_voltage') is not None:
if ups.get('input_voltage') is not None:
metrics.append(f'# HELP proxmox_ups_input_voltage_volts UPS input voltage in volts')
metrics.append(f'# TYPE proxmox_ups_input_voltage_volts gauge')
metrics.append(f'proxmox_ups_input_voltage_volts{{node="{node}",ups="{ups_name}"}} {ups["line_voltage"]} {timestamp}')
metrics.append(f'proxmox_ups_input_voltage_volts{{node="{node}",ups="{ups_name}"}} {ups["input_voltage"]} {timestamp}') # This is a string, might need conversion
except Exception as e:
print(f"[v0] Error getting hardware metrics for Prometheus: {e}")