added GPIO16
2026-05-13 02:24:13 +02:00

29 lines
1.1 KiB
Markdown

# Meshcore EVO - AOI Edition
Diese Firmware wurde verändert:
* Modifikation der Sensor-Firmware
* Gestestet mit Heltec V4
* Sollte theoretisch mit allen ESP-Boards funktionieren
* GPIO15 und GPIO16 sind jeweils als Pullup-Eingang definiert.
### Neue Befehle:
* "io" gibt den zustand aller 32 GPIO-Pins als Hexcode aus. (Die originale FW gibt eine festcodierte 0 aus.)
* "bin" gibt den zustand aller 32 GPIO-Pins als Binärcode aus
* "readpin <pin>" gibt den zustand eines Pins als ON/OFF aus
### Verwendung:
* GPIO 15 oder 16 können z.B. mit einm Schalter oder Relais verbunden werden.
* Der standardmäßige zustand ist "ON", da intern 3,3V anliegen (Pull-Up Widerstand)
* Wird ein GPIO nach Masse geschaltet, wechselt der Zustand nach "OFF"
#### Beispiel:
Eine laufende Anlage hält ein Überwachungsrelais ständig angezogen, und schaltet GPIO15
nach Masse. Der Zustand ist daher "OFF" (das könnte als Alarm: OFF gelesen werden).
Fällt die Stromversorgung der Anlage aus, fällt das Relais ab. Der Zustand von GPIO15
wechselt daher auf "ON" (das könnte wiederum als Alarm: ON gelesen werden)