feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters (#1375)
* feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters Real inverters are much less efficient at low load than at rated power (e.g. 0.80 at 2 % vs. 0.93 at 7 % load). A constant dc_to_ac_efficiency overrates night-time battery discharge into a small base load and, with it, arbitrage and grid charging. Add two optional inverter settings for the GENETIC optimizer: - dc_to_ac_efficiency_curve: list of (load_fraction, efficiency) points, load fraction = AC power / max_power_w. Points must be strictly increasing in [0, 1] with efficiencies in (0, 1]; at least two points. Linear interpolation, clamped at both ends. When set, the curve replaces dc_to_ac_efficiency. - dc_to_ac_efficiency_reference_load_fraction (default 0.06): load at which the curve values stored energy without a specific conversion. Battery discharges in Inverter.process_energy() use the efficiency at the AC energy of each conversion. The end-of-horizon value, the terminal and tail value curves and the AC charge break-even penalty use Inverter.reference_dc_to_ac_efficiency. Without a curve, dc_to_ac_efficiency_at() and the reference efficiency return dc_to_ac_efficiency itself, so results are bit-identical to the previous model. GENETIC0 is unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> * fix(devices): evaluate the efficiency curve at the delivered AC load When the battery limits a discharge (low state of charge or its power limit), the conversion ran with the efficiency of the requested AC energy. With a 1000 Wh battery at 10 % SoC, a 1000 W inverter and the curve [(0, .8), (.5, .95), (1, .95)], a request of 500 Wh AC returned 95 Wh AC from the available 100 Wh DC, although the curve gives 82.5 % at that load. The delivered AC energy now solves a = dc * efficiency(a / rated) exactly on the piecewise-linear curve (solve_ac_for_dc_energy), bounded by the request. Unlimited discharges and inverters without a curve are unchanged. Regression tests use a real Battery: low SoC and a power-limited discharge, each with 60- and 15-minute slots, battery discharge losses, the load path through process_energy, and constant efficiency. * docs: regenerate OpenAPI for the efficiency-curve fix --------- Co-authored-by: Christin <christin@BigBrother.bikini.bottom.zone> Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com> Co-authored-by: Andreas <drbacke@gmx.de>
This commit is contained in:
co-authored by
Christin
Claude Opus 5.5
Andreas
parent
560370281f
commit
7f26ea3f3f
@@ -299,6 +299,39 @@ The inverter supports separate AC↔DC conversion efficiencies:
|
||||
Must be > 0. Default `1.0`.
|
||||
- `max_ac_charge_power_w`: Maximum AC charging power in watts. `null` = no additional limit.
|
||||
Set to `0` to disable AC charging. Default `null`.
|
||||
- `dc_to_ac_efficiency_curve`: Optional load-dependent DC→AC efficiency as a list of
|
||||
`[load_fraction, efficiency]` points, with the load fraction relative to `max_power_w`.
|
||||
Real inverters are much less efficient at low load, e.g. when the battery serves a small
|
||||
night-time base load. The points must be strictly increasing in load fraction (0-1) with
|
||||
efficiencies in (0, 1]; values in between are interpolated linearly, values outside are
|
||||
clamped to the first/last point. When set, the curve replaces `dc_to_ac_efficiency` for
|
||||
battery discharge. The efficiency is always the one at the AC power that is delivered: if
|
||||
the battery limits a discharge (low state of charge or its power limit), the conversion is
|
||||
evaluated at that lower load, not at the requested one. Default `null` (constant
|
||||
`dc_to_ac_efficiency`, unchanged behaviour).
|
||||
- `dc_to_ac_efficiency_reference_load_fraction`: Load fraction at which the curve is evaluated
|
||||
where stored energy is valued without a specific discharge, e.g. the energy left in the
|
||||
battery at the end of the horizon and the AC charge break-even. Choose the typical load
|
||||
the battery serves. Only used with `dc_to_ac_efficiency_curve`. Default `0.06`.
|
||||
|
||||
**Example with an efficiency curve:**
|
||||
|
||||
```json
|
||||
{
|
||||
"devices": {
|
||||
"inverters": {
|
||||
"inv1": {
|
||||
"max_power_w": 10000,
|
||||
"battery_id": "bat1",
|
||||
"dc_to_ac_efficiency_curve": [
|
||||
[0.02, 0.80], [0.07, 0.93], [0.30, 0.96], [1.00, 0.95]
|
||||
],
|
||||
"dc_to_ac_efficiency_reference_load_fraction": 0.06
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||