feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters (#1375)
* feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters Real inverters are much less efficient at low load than at rated power (e.g. 0.80 at 2 % vs. 0.93 at 7 % load). A constant dc_to_ac_efficiency overrates night-time battery discharge into a small base load and, with it, arbitrage and grid charging. Add two optional inverter settings for the GENETIC optimizer: - dc_to_ac_efficiency_curve: list of (load_fraction, efficiency) points, load fraction = AC power / max_power_w. Points must be strictly increasing in [0, 1] with efficiencies in (0, 1]; at least two points. Linear interpolation, clamped at both ends. When set, the curve replaces dc_to_ac_efficiency. - dc_to_ac_efficiency_reference_load_fraction (default 0.06): load at which the curve values stored energy without a specific conversion. Battery discharges in Inverter.process_energy() use the efficiency at the AC energy of each conversion. The end-of-horizon value, the terminal and tail value curves and the AC charge break-even penalty use Inverter.reference_dc_to_ac_efficiency. Without a curve, dc_to_ac_efficiency_at() and the reference efficiency return dc_to_ac_efficiency itself, so results are bit-identical to the previous model. GENETIC0 is unchanged. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> * fix(devices): evaluate the efficiency curve at the delivered AC load When the battery limits a discharge (low state of charge or its power limit), the conversion ran with the efficiency of the requested AC energy. With a 1000 Wh battery at 10 % SoC, a 1000 W inverter and the curve [(0, .8), (.5, .95), (1, .95)], a request of 500 Wh AC returned 95 Wh AC from the available 100 Wh DC, although the curve gives 82.5 % at that load. The delivered AC energy now solves a = dc * efficiency(a / rated) exactly on the piecewise-linear curve (solve_ac_for_dc_energy), bounded by the request. Unlimited discharges and inverters without a curve are unchanged. Regression tests use a real Battery: low SoC and a power-limited discharge, each with 60- and 15-minute slots, battery discharge losses, the load path through process_energy, and constant efficiency. * docs: regenerate OpenAPI for the efficiency-curve fix --------- Co-authored-by: Christin <christin@BigBrother.bikini.bottom.zone> Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com> Co-authored-by: Andreas <drbacke@gmx.de>
This commit is contained in:
co-authored by
Christin
Claude Opus 5.5
Andreas
parent
560370281f
commit
7f26ea3f3f
+186
@@ -11304,6 +11304,70 @@
|
||||
"GENETIC0"
|
||||
]
|
||||
},
|
||||
"dc_to_ac_efficiency_curve": {
|
||||
"anyOf": [
|
||||
{
|
||||
"items": {
|
||||
"prefixItems": [
|
||||
{
|
||||
"type": "number"
|
||||
},
|
||||
{
|
||||
"type": "number"
|
||||
}
|
||||
],
|
||||
"type": "array",
|
||||
"maxItems": 2,
|
||||
"minItems": 2
|
||||
},
|
||||
"type": "array"
|
||||
},
|
||||
{
|
||||
"type": "null"
|
||||
}
|
||||
],
|
||||
"title": "Dc To Ac Efficiency Curve",
|
||||
"description": "Load-dependent efficiency of DC\u2192AC conversion for battery discharging as a list of [load_fraction, efficiency] points. The load fraction is the AC power relative to max_power_w (0\u20131); points must be strictly increasing in load fraction, efficiencies in (0, 1]. Values are interpolated linearly and clamped to the first/last point. When set, the curve replaces dc_to_ac_efficiency. null keeps the constant dc_to_ac_efficiency. Default null.",
|
||||
"examples": [
|
||||
null,
|
||||
[
|
||||
[
|
||||
0.02,
|
||||
0.8
|
||||
],
|
||||
[
|
||||
0.07,
|
||||
0.93
|
||||
],
|
||||
[
|
||||
0.3,
|
||||
0.96
|
||||
],
|
||||
[
|
||||
1.0,
|
||||
0.95
|
||||
]
|
||||
]
|
||||
],
|
||||
"x-scope": [
|
||||
"GENETIC"
|
||||
]
|
||||
},
|
||||
"dc_to_ac_efficiency_reference_load_fraction": {
|
||||
"type": "number",
|
||||
"maximum": 1.0,
|
||||
"minimum": 0.0,
|
||||
"title": "Dc To Ac Efficiency Reference Load Fraction",
|
||||
"description": "Load fraction of max_power_w (0\u20131) at which dc_to_ac_efficiency_curve is evaluated to value stored battery energy without a specific conversion (remaining energy at the end of the horizon, AC charge break-even). Should represent the typical load served by the battery, e.g. the night-time base load. Only used with dc_to_ac_efficiency_curve. Default 0.06.",
|
||||
"default": 0.06,
|
||||
"examples": [
|
||||
0.06,
|
||||
0.1
|
||||
],
|
||||
"x-scope": [
|
||||
"GENETIC"
|
||||
]
|
||||
},
|
||||
"max_ac_charge_power_w": {
|
||||
"anyOf": [
|
||||
{
|
||||
@@ -11715,6 +11779,70 @@
|
||||
"GENETIC0"
|
||||
]
|
||||
},
|
||||
"dc_to_ac_efficiency_curve": {
|
||||
"anyOf": [
|
||||
{
|
||||
"items": {
|
||||
"prefixItems": [
|
||||
{
|
||||
"type": "number"
|
||||
},
|
||||
{
|
||||
"type": "number"
|
||||
}
|
||||
],
|
||||
"type": "array",
|
||||
"maxItems": 2,
|
||||
"minItems": 2
|
||||
},
|
||||
"type": "array"
|
||||
},
|
||||
{
|
||||
"type": "null"
|
||||
}
|
||||
],
|
||||
"title": "Dc To Ac Efficiency Curve",
|
||||
"description": "Load-dependent efficiency of DC\u2192AC conversion for battery discharging as a list of [load_fraction, efficiency] points. The load fraction is the AC power relative to max_power_w (0\u20131); points must be strictly increasing in load fraction, efficiencies in (0, 1]. Values are interpolated linearly and clamped to the first/last point. When set, the curve replaces dc_to_ac_efficiency. null keeps the constant dc_to_ac_efficiency. Default null.",
|
||||
"examples": [
|
||||
null,
|
||||
[
|
||||
[
|
||||
0.02,
|
||||
0.8
|
||||
],
|
||||
[
|
||||
0.07,
|
||||
0.93
|
||||
],
|
||||
[
|
||||
0.3,
|
||||
0.96
|
||||
],
|
||||
[
|
||||
1.0,
|
||||
0.95
|
||||
]
|
||||
]
|
||||
],
|
||||
"x-scope": [
|
||||
"GENETIC"
|
||||
]
|
||||
},
|
||||
"dc_to_ac_efficiency_reference_load_fraction": {
|
||||
"type": "number",
|
||||
"maximum": 1.0,
|
||||
"minimum": 0.0,
|
||||
"title": "Dc To Ac Efficiency Reference Load Fraction",
|
||||
"description": "Load fraction of max_power_w (0\u20131) at which dc_to_ac_efficiency_curve is evaluated to value stored battery energy without a specific conversion (remaining energy at the end of the horizon, AC charge break-even). Should represent the typical load served by the battery, e.g. the night-time base load. Only used with dc_to_ac_efficiency_curve. Default 0.06.",
|
||||
"default": 0.06,
|
||||
"examples": [
|
||||
0.06,
|
||||
0.1
|
||||
],
|
||||
"x-scope": [
|
||||
"GENETIC"
|
||||
]
|
||||
},
|
||||
"max_ac_charge_power_w": {
|
||||
"anyOf": [
|
||||
{
|
||||
@@ -12147,6 +12275,64 @@
|
||||
1.0
|
||||
]
|
||||
},
|
||||
"dc_to_ac_efficiency_curve": {
|
||||
"anyOf": [
|
||||
{
|
||||
"items": {
|
||||
"prefixItems": [
|
||||
{
|
||||
"type": "number"
|
||||
},
|
||||
{
|
||||
"type": "number"
|
||||
}
|
||||
],
|
||||
"type": "array",
|
||||
"maxItems": 2,
|
||||
"minItems": 2
|
||||
},
|
||||
"type": "array"
|
||||
},
|
||||
{
|
||||
"type": "null"
|
||||
}
|
||||
],
|
||||
"title": "Dc To Ac Efficiency Curve",
|
||||
"description": "Load-dependent efficiency of DC to AC conversion as a list of (load_fraction, efficiency) points. The load fraction is the AC power of the conversion relative to max_power_wh [0.0 ... 1.0]; points must be strictly increasing in load fraction, efficiencies in (0, 1]. Values are interpolated linearly and clamped to the first/last point. When set, the curve replaces dc_to_ac_efficiency. Default None (constant dc_to_ac_efficiency).",
|
||||
"examples": [
|
||||
null,
|
||||
[
|
||||
[
|
||||
0.02,
|
||||
0.8
|
||||
],
|
||||
[
|
||||
0.07,
|
||||
0.93
|
||||
],
|
||||
[
|
||||
0.3,
|
||||
0.96
|
||||
],
|
||||
[
|
||||
1.0,
|
||||
0.95
|
||||
]
|
||||
]
|
||||
]
|
||||
},
|
||||
"dc_to_ac_efficiency_reference_load_fraction": {
|
||||
"type": "number",
|
||||
"maximum": 1.0,
|
||||
"minimum": 0.0,
|
||||
"title": "Dc To Ac Efficiency Reference Load Fraction",
|
||||
"description": "Load fraction at which dc_to_ac_efficiency_curve is evaluated where stored battery energy is valued without a specific conversion (e.g. remaining battery energy at the end of the horizon, AC charge break-even). Should represent the typical load the battery serves, e.g. the night-time base load. Only used with dc_to_ac_efficiency_curve. Default 0.06.",
|
||||
"default": 0.06,
|
||||
"examples": [
|
||||
0.06,
|
||||
0.1
|
||||
]
|
||||
},
|
||||
"max_ac_charge_power_w": {
|
||||
"anyOf": [
|
||||
{
|
||||
|
||||
Reference in New Issue