feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters (#1375)

* feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters

Real inverters are much less efficient at low load than at rated power
(e.g. 0.80 at 2 % vs. 0.93 at 7 % load). A constant dc_to_ac_efficiency
overrates night-time battery discharge into a small base load and, with
it, arbitrage and grid charging.

Add two optional inverter settings for the GENETIC optimizer:

- dc_to_ac_efficiency_curve: list of (load_fraction, efficiency) points,
  load fraction = AC power / max_power_w. Points must be strictly
  increasing in [0, 1] with efficiencies in (0, 1]; at least two points.
  Linear interpolation, clamped at both ends. When set, the curve
  replaces dc_to_ac_efficiency.
- dc_to_ac_efficiency_reference_load_fraction (default 0.06): load at
  which the curve values stored energy without a specific conversion.

Battery discharges in Inverter.process_energy() use the efficiency at
the AC energy of each conversion. The end-of-horizon value, the terminal
and tail value curves and the AC charge break-even penalty use
Inverter.reference_dc_to_ac_efficiency.

Without a curve, dc_to_ac_efficiency_at() and the reference efficiency
return dc_to_ac_efficiency itself, so results are bit-identical to the
previous model. GENETIC0 is unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

* fix(devices): evaluate the efficiency curve at the delivered AC load

When the battery limits a discharge (low state of charge or its power
limit), the conversion ran with the efficiency of the requested AC energy.
With a 1000 Wh battery at 10 % SoC, a 1000 W inverter and the curve
[(0, .8), (.5, .95), (1, .95)], a request of 500 Wh AC returned 95 Wh AC
from the available 100 Wh DC, although the curve gives 82.5 % at that load.

The delivered AC energy now solves a = dc * efficiency(a / rated) exactly on
the piecewise-linear curve (solve_ac_for_dc_energy), bounded by the request.
Unlimited discharges and inverters without a curve are unchanged.

Regression tests use a real Battery: low SoC and a power-limited discharge,
each with 60- and 15-minute slots, battery discharge losses, the load path
through process_energy, and constant efficiency.

* docs: regenerate OpenAPI for the efficiency-curve fix

---------

Co-authored-by: Christin <christin@BigBrother.bikini.bottom.zone>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
Co-authored-by: Andreas <drbacke@gmx.de>
This commit is contained in:
Christin
2026-10-11 10:45:44 +02:00
committed by GitHub
co-authored by Christin Claude Opus 5.5 Andreas
parent 560370281f
commit 7f26ea3f3f
10 changed files with 1175 additions and 22 deletions
+93 -8
View File
@@ -1,8 +1,13 @@
from typing import Optional
from loguru import logger
from pydantic import Field
from pydantic import Field, field_validator
from akkudoktoreos.devices.devicesabc import (
interpolate_efficiency_curve,
solve_ac_for_dc_energy,
validate_efficiency_curve,
)
from akkudoktoreos.devices.genetic.battery import Battery
from akkudoktoreos.optimization.genetic.geneticdevices import DeviceParameters
from akkudoktoreos.prediction.interpolator import get_eos_load_interpolator
@@ -44,6 +49,37 @@ class InverterParameters(DeviceParameters):
"examples": [0.95, 1.0],
},
)
dc_to_ac_efficiency_curve: Optional[list[tuple[float, float]]] = Field(
default=None,
json_schema_extra={
"description": (
"Load-dependent efficiency of DC to AC conversion as a list of "
"(load_fraction, efficiency) points. The load fraction is the AC power "
"of the conversion relative to max_power_wh [0.0 ... 1.0]; points must be "
"strictly increasing in load fraction, efficiencies in (0, 1]. Values are "
"interpolated linearly and clamped to the first/last point. When set, the "
"curve replaces dc_to_ac_efficiency. "
"Default None (constant dc_to_ac_efficiency)."
),
"examples": [None, [[0.02, 0.8], [0.07, 0.93], [0.3, 0.96], [1.0, 0.95]]],
},
)
dc_to_ac_efficiency_reference_load_fraction: float = Field(
default=0.06,
ge=0,
le=1,
json_schema_extra={
"description": (
"Load fraction at which dc_to_ac_efficiency_curve is evaluated where "
"stored battery energy is valued without a specific conversion "
"(e.g. remaining battery energy at the end of the horizon, AC charge "
"break-even). Should represent the typical load the battery serves, "
"e.g. the night-time base load. Only used with dc_to_ac_efficiency_curve. "
"Default 0.06."
),
"examples": [0.06, 0.1],
},
)
max_ac_charge_power_w: Optional[float] = Field(
default=None,
ge=0,
@@ -69,6 +105,13 @@ class InverterParameters(DeviceParameters):
},
)
@field_validator("dc_to_ac_efficiency_curve")
@classmethod
def _validate_dc_to_ac_efficiency_curve(
cls, value: Optional[list[tuple[float, float]]]
) -> Optional[list[tuple[float, float]]]:
return validate_efficiency_curve(value)
class Inverter:
def __init__(
@@ -93,11 +136,32 @@ class Inverter:
self.max_power_wh = self.parameters.max_power_wh * self.slot_duration_h
self.dc_to_ac_efficiency = self.parameters.dc_to_ac_efficiency
self.ac_to_dc_efficiency = self.parameters.ac_to_dc_efficiency
self.dc_to_ac_efficiency_curve = self.parameters.dc_to_ac_efficiency_curve
# DC-to-AC efficiency used to value stored battery energy where no single
# conversion is known (end-of-horizon value, AC charge break-even). With
# a curve it is the efficiency at the configured reference load.
self.reference_dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(
self.parameters.dc_to_ac_efficiency_reference_load_fraction * self.max_power_wh
)
# This value remains a power [W]. GeneticSimulation converts it into a
# slot-independent charge-factor limit.
self.max_ac_charge_power_w = self.parameters.max_ac_charge_power_w
self.ac_charge_limits_total_charge = self.parameters.ac_charge_limits_total_charge
def dc_to_ac_efficiency_at(self, ac_wh: float) -> float:
"""Return the DC-to-AC efficiency of a conversion delivering ``ac_wh`` in one slot.
Without ``dc_to_ac_efficiency_curve`` this is the constant
``dc_to_ac_efficiency``. With a curve, the efficiency is interpolated at
the load fraction ``ac_wh / max_power_wh`` of this slot. ``max_power_wh``
is already scaled to the slot duration, so the fraction equals the mean
AC power relative to the rated power.
"""
if self.dc_to_ac_efficiency_curve is None:
return self.dc_to_ac_efficiency
load_fraction = ac_wh / self.max_power_wh if self.max_power_wh > 0 else 0.0
return interpolate_efficiency_curve(self.dc_to_ac_efficiency_curve, load_fraction)
def ac_charge_factor(self, factor: float) -> float:
"""Return the AC charge factor the inverter can actually execute.
@@ -161,9 +225,26 @@ class Inverter:
if not self.battery or requested_ac_wh <= 0.0:
return 0.0, 0.0
dc_request = requested_ac_wh / self.dc_to_ac_efficiency
# With an efficiency curve, the efficiency is taken at the requested AC
# energy of this conversion.
dc_to_ac_efficiency = self.dc_to_ac_efficiency_at(requested_ac_wh)
dc_request = requested_ac_wh / dc_to_ac_efficiency
battery_discharge_dc, discharge_losses = self.battery.discharge_energy(dc_request, hour)
battery_discharge_ac = battery_discharge_dc * self.dc_to_ac_efficiency
if self.dc_to_ac_efficiency_curve is not None and battery_discharge_dc < dc_request * (
1.0 - 1e-12
):
# The battery delivered less than requested (low state of charge or
# its power limit). The conversion then runs at a lower AC load than
# requested, so the efficiency must be the one at the AC energy that
# is actually delivered, not at the request.
battery_discharge_ac = solve_ac_for_dc_energy(
self.dc_to_ac_efficiency_curve,
battery_discharge_dc,
self.max_power_wh,
requested_ac_wh,
)
else:
battery_discharge_ac = battery_discharge_dc * dc_to_ac_efficiency
inverter_discharge_losses = battery_discharge_dc - battery_discharge_ac
return battery_discharge_ac, discharge_losses + inverter_discharge_losses
@@ -258,16 +339,20 @@ class Inverter:
if allow_battery_grid_export and self.battery and remaining_inverter_ac_capacity > 0.0:
export_factor = min(max(float(battery_grid_export_factor), 0.0), 1.0)
remaining_battery_ac = (
self.battery.remaining_discharge_energy_wh(hour) * self.dc_to_ac_efficiency
# Upper bounds of the export. With an efficiency curve, the
# efficiency is estimated at the DC energy of each bound; the
# conversion itself in _discharge_battery_to_ac() is exact and is
# limited by the energy the battery can actually deliver.
remaining_battery_dc = self.battery.remaining_discharge_energy_wh(hour)
remaining_battery_ac = remaining_battery_dc * self.dc_to_ac_efficiency_at(
remaining_battery_dc
)
# The rate caps the export against the battery's *rated* discharge
# power, so it stays a plain power setpoint ("export at 50 %") that
# does not silently grow when self-consumption used less of the slot.
# At factor 1.0 this bound never binds; behaviour is unchanged.
rated_export_ac = (
self.battery.rated_discharge_energy_wh() * export_factor * self.dc_to_ac_efficiency
)
rated_export_dc = self.battery.rated_discharge_energy_wh() * export_factor
rated_export_ac = rated_export_dc * self.dc_to_ac_efficiency_at(rated_export_dc)