feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters (#1375)

* feat(devices): add load-dependent DC-to-AC efficiency curve for GENETIC inverters

Real inverters are much less efficient at low load than at rated power
(e.g. 0.80 at 2 % vs. 0.93 at 7 % load). A constant dc_to_ac_efficiency
overrates night-time battery discharge into a small base load and, with
it, arbitrage and grid charging.

Add two optional inverter settings for the GENETIC optimizer:

- dc_to_ac_efficiency_curve: list of (load_fraction, efficiency) points,
  load fraction = AC power / max_power_w. Points must be strictly
  increasing in [0, 1] with efficiencies in (0, 1]; at least two points.
  Linear interpolation, clamped at both ends. When set, the curve
  replaces dc_to_ac_efficiency.
- dc_to_ac_efficiency_reference_load_fraction (default 0.06): load at
  which the curve values stored energy without a specific conversion.

Battery discharges in Inverter.process_energy() use the efficiency at
the AC energy of each conversion. The end-of-horizon value, the terminal
and tail value curves and the AC charge break-even penalty use
Inverter.reference_dc_to_ac_efficiency.

Without a curve, dc_to_ac_efficiency_at() and the reference efficiency
return dc_to_ac_efficiency itself, so results are bit-identical to the
previous model. GENETIC0 is unchanged.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>

* fix(devices): evaluate the efficiency curve at the delivered AC load

When the battery limits a discharge (low state of charge or its power
limit), the conversion ran with the efficiency of the requested AC energy.
With a 1000 Wh battery at 10 % SoC, a 1000 W inverter and the curve
[(0, .8), (.5, .95), (1, .95)], a request of 500 Wh AC returned 95 Wh AC
from the available 100 Wh DC, although the curve gives 82.5 % at that load.

The delivered AC energy now solves a = dc * efficiency(a / rated) exactly on
the piecewise-linear curve (solve_ac_for_dc_energy), bounded by the request.
Unlimited discharges and inverters without a curve are unchanged.

Regression tests use a real Battery: low SoC and a power-limited discharge,
each with 60- and 15-minute slots, battery discharge losses, the load path
through process_energy, and constant efficiency.

* docs: regenerate OpenAPI for the efficiency-curve fix

---------

Co-authored-by: Christin <christin@BigBrother.bikini.bottom.zone>
Co-authored-by: Claude Opus 5.5 <noreply@anthropic.com>
Co-authored-by: Andreas <drbacke@gmx.de>
This commit is contained in:
Christin
2026-10-11 10:45:44 +02:00
committed by GitHub
co-authored by Christin Claude Opus 5.5 Andreas
parent 560370281f
commit 7f26ea3f3f
10 changed files with 1175 additions and 22 deletions
@@ -1002,7 +1002,7 @@ class GeneticOptimization(OptimizationBase):
self._terminal_value_reason = "terminal_value_mode is FIXED"
return None
dc_to_ac = inverter.dc_to_ac_efficiency if inverter else 1.0
dc_to_ac = inverter.reference_dc_to_ac_efficiency if inverter else 1.0
# A full battery, expressed in the same unit as the curve: AC energy
# that can actually leave the house.
max_energy_wh = (
@@ -1125,7 +1125,7 @@ class GeneticOptimization(OptimizationBase):
# Usable DC energy, converted to the AC energy that can serve a load.
energy_wh = battery.current_energy_content()
if self.simulation.inverter:
energy_wh *= self.simulation.inverter.dc_to_ac_efficiency
energy_wh *= self.simulation.inverter.reference_dc_to_ac_efficiency
curve = getattr(self, "_terminal_value_curve", None)
if curve is not None and curve.energy_wh:
@@ -3129,12 +3129,15 @@ class GeneticOptimization(OptimizationBase):
inv = self.simulation.inverter
bat = self.simulation.battery
# Full round-trip efficiency: 1 Wh drawn from grid → η Wh delivered to AC load
# Full round-trip efficiency: 1 Wh drawn from grid → η Wh delivered to AC load.
# The later discharge has no known size here, so the DC-to-AC part
# is the efficiency at the inverter's reference load (equal to
# dc_to_ac_efficiency without an efficiency curve).
round_trip_eff = (
inv.ac_to_dc_efficiency
* bat.charging_efficiency
* bat.discharging_efficiency
* inv.dc_to_ac_efficiency
* inv.reference_dc_to_ac_efficiency
)
# Configurable penalty multiplier (default 1 = economic loss in €)
@@ -3160,7 +3163,7 @@ class GeneticOptimization(OptimizationBase):
free_ac_wh = (
max(0.0, initial_soc_wh - bat.min_soc_wh)
* bat.discharging_efficiency
* inv.dc_to_ac_efficiency
* inv.reference_dc_to_ac_efficiency
)
# Prices/loads/free energy are constant within one optimization
@@ -3186,7 +3189,8 @@ class GeneticOptimization(OptimizationBase):
# corresponding cost per useful/exported AC Wh.
lcos_per_wh_dc = getattr(bat, "levelized_cost_of_storage_kwh", 0.0) / 1000.0
break_even_price = (
charge_price / round_trip_eff + lcos_per_wh_dc / inv.dc_to_ac_efficiency
charge_price / round_trip_eff
+ lcos_per_wh_dc / inv.reference_dc_to_ac_efficiency
)
best_uncovered_price = best_prices[hour]
@@ -128,7 +128,7 @@ class TailValueCurve(TerminalValueCurve):
battery=bat,
slot_duration_h=context["slot_duration_h"],
)
conversion = bat.discharging_efficiency * inv.dc_to_ac_efficiency
conversion = bat.discharging_efficiency * inv.reference_dc_to_ac_efficiency
state_wh = bat.min_soc_wh + (energy_wh / conversion if conversion > 0 else 0.0)
state_wh = float(np.clip(state_wh, bat.min_soc_wh, bat.max_soc_wh))
plan: list[TailPlanSlot] = []
@@ -231,7 +231,9 @@ def build_tail_value_curve(
bat.charge_array = np.zeros(1, dtype=float)
inv = Inverter(inverter.parameters, battery=bat, slot_duration_h=battery.slot_duration_h)
states = np.linspace(bat.min_soc_wh, bat.max_soc_wh, grid_points)
usable = (states - bat.min_soc_wh) * bat.discharging_efficiency * inv.dc_to_ac_efficiency
usable = (
(states - bat.min_soc_wh) * bat.discharging_efficiency * inv.reference_dc_to_ac_efficiency
)
continuation_values = np.array([continuation.value(e) for e in usable])
operating_values = np.zeros(len(states))
values = continuation_values.copy()