feat: add pvlib pv forecast provider (#1214)
Add a PV forecast provider that calculates the forecast using a PVLib system model and weather forecast from the EOS weather forecast provider. Additional module and inverter models can be easily added as the database is build from PVLib and SAM databases and a bundled csv file. The module model and inververt model names are provided by new endpoints to be used in configuration. The provider is based on the fantastic work of EMHASS. See https://github.com/davidusb-geek/emhass/blob/master/src/emhass/forecast.py A short description of the provider is added to the documentation. Besides the new features there are the fixes and improvements: * feat: improve EOSdash config page * fix: kex_to_series for start_datetime Make key_to_series always start the series at start_datetime. * fix: default provider for GENETIC and GENETIC0 optimization To make the default less dependent on internet servers (with API changes and availability issues) the default for PVForecast is set to PVForecastPVLib and for ElecPrice to ElecPriceFixed. The default weather provider is changed to OpenMeteo. * fix: EOSdash display resampled prediction values Make EOSdash display resampled prediction values where resampling fits to the prediction value type. Use bar width that fits to 15 minutes value samples. * chore: add a UI hints system to EOSdash The UI hints system eases the definition of forms for configuration items. There are also forms for items in maps and lists. These forms allow to add and delete items to/ from maps and lists. The forms ensure that all required fields of newly added items are filled. * chore: Create an enum for valid optimization algorithms * chore. Make config also provide the available energy management modes. Used for configuration hints. * chore: Randomize default device id in configuration Signed-off-by: Bobby Noelte <b0661n0e17e@gmail.com>
This commit is contained in:
@@ -18,6 +18,7 @@
|
||||
| provider | `EOS_PVFORECAST__PROVIDER` | `str | None` | `rw` | `None` | PVForecast provider id of provider to be used. |
|
||||
| providers | | `list[str]` | `ro` | `N/A` | Available PVForecast provider ids. |
|
||||
| pvforecastimport | `EOS_PVFORECAST__PVFORECASTIMPORT` | `PVForecastImportCommonSettings` | `rw` | `required` | PV forecast import provider settings |
|
||||
| pvlib | `EOS_PVFORECAST__PVLIB` | `PVForecastPVLibCommonSettings` | `rw` | `required` | PVLib provider settings |
|
||||
| pvnode | `EOS_PVFORECAST__PVNODE` | `PVForecastPVNodeCommonSettings` | `rw` | `required` | PVNode provider settings |
|
||||
| solcast | `EOS_PVFORECAST__SOLCAST` | `PVForecastSolcastCommonSettings` | `rw` | `required` | Solcast provider settings |
|
||||
| vrm | `EOS_PVFORECAST__VRM` | `PVForecastVrmCommonSettings` | `rw` | `required` | Victron Remote Management (VRM) provider settings |
|
||||
@@ -41,6 +42,7 @@
|
||||
"token": "your-token",
|
||||
"site_id": 12345
|
||||
},
|
||||
"pvlib": {},
|
||||
"pvnode": {
|
||||
"api_key": "",
|
||||
"site_id": null,
|
||||
@@ -122,6 +124,7 @@
|
||||
"token": "your-token",
|
||||
"site_id": 12345
|
||||
},
|
||||
"pvlib": {},
|
||||
"pvnode": {
|
||||
"api_key": "",
|
||||
"site_id": null,
|
||||
@@ -183,11 +186,12 @@
|
||||
"max_planes": 1,
|
||||
"providers": [
|
||||
"PVForecastAkkudoktor",
|
||||
"PVForecastVrm",
|
||||
"PVForecastPVNode",
|
||||
"PVForecastForecastSolar",
|
||||
"PVForecastImport",
|
||||
"PVForecastPVLib",
|
||||
"PVForecastPVNode",
|
||||
"PVForecastSolcast",
|
||||
"PVForecastImport"
|
||||
"PVForecastVrm"
|
||||
],
|
||||
"planes_peakpower": [
|
||||
5.0,
|
||||
@@ -317,6 +321,32 @@
|
||||
```
|
||||
<!-- pyml enable line-length -->
|
||||
|
||||
### Common settings for pvforecast data calculation with PVLib
|
||||
|
||||
<!-- pyml disable line-length -->
|
||||
:::{table} pvforecast::pvlib
|
||||
:widths: 10 10 5 5 30
|
||||
:align: left
|
||||
|
||||
| Name | Type | Read-Only | Default | Description |
|
||||
| ---- | ---- | --------- | ------- | ----------- |
|
||||
:::
|
||||
<!-- pyml enable line-length -->
|
||||
|
||||
<!-- pyml disable no-emphasis-as-heading -->
|
||||
**Example Input/Output**
|
||||
<!-- pyml enable no-emphasis-as-heading -->
|
||||
|
||||
<!-- pyml disable line-length -->
|
||||
```json
|
||||
{
|
||||
"pvforecast": {
|
||||
"pvlib": {}
|
||||
}
|
||||
}
|
||||
```
|
||||
<!-- pyml enable line-length -->
|
||||
|
||||
### Common settings for pvforecast data import from file or JSON string
|
||||
|
||||
<!-- pyml disable line-length -->
|
||||
@@ -357,13 +387,13 @@
|
||||
|
||||
| Name | Type | Read-Only | Default | Description |
|
||||
| ---- | ---- | --------- | ------- | ----------- |
|
||||
| albedo | `float | None` | `rw` | `None` | Proportion of the light hitting the ground that it reflects back. |
|
||||
| albedo | `float | None` | `rw` | `0.2` | Proportion of the light hitting the ground that it reflects back. |
|
||||
| inverter_model | `str | None` | `rw` | `None` | Model of the inverter of this plane. |
|
||||
| inverter_paco | `int | None` | `rw` | `None` | AC power rating of the inverter [W]. |
|
||||
| loss | `float | None` | `rw` | `14.0` | Sum of PV system losses in percent |
|
||||
| module_model | `str | None` | `rw` | `None` | Model of the PV modules of this plane. |
|
||||
| modules_per_string | `int | None` | `rw` | `None` | Number of the PV modules of the strings of this plane. |
|
||||
| mountingplace | `str | None` | `rw` | `free` | Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated. |
|
||||
| mountingplace | `str | None` | `rw` | `building` | Type of mounting for PV system. Options are 'free' for free-standing and 'building' for building-integrated. |
|
||||
| optimal_surface_tilt | `bool | None` | `rw` | `False` | Calculate the optimum tilt angle. Ignored for two-axis tracking. |
|
||||
| optimalangles | `bool | None` | `rw` | `False` | Calculate the optimum tilt and azimuth angles. Ignored for two-axis tracking. |
|
||||
| peakpower | `float | None` | `rw` | `None` | Nominal power of PV system in kW. |
|
||||
@@ -395,7 +425,7 @@
|
||||
],
|
||||
"peakpower": 5.0,
|
||||
"pvtechchoice": "crystSi",
|
||||
"mountingplace": "free",
|
||||
"mountingplace": "building",
|
||||
"loss": 14.0,
|
||||
"trackingtype": 0,
|
||||
"optimal_surface_tilt": false,
|
||||
|
||||
Reference in New Issue