mirror of
https://github.com/Akkudoktor-EOS/EOS.git
synced 2026-11-25 15:06:20 +01:00
The file cache keyed provider request methods on their arguments and
code only. They take no arguments besides self and read location,
planes, tokens and past days from the configuration, so after a
configuration change they got the response for the previous one until
the 1-hour TTL expired, also across restarts.
cache_in_file takes an optional key_context, called with the arguments
of each call; a hash of its result is part of the key. Each provider
request declares the settings it is built from with
cache_request("general/latitude", ...), which builds the key context
from them. A change of other settings, e.g. an import value or a tariff
that an adapter pushes on every run, keeps the cache entry. The MD5
digest of the declared values is computed once per settings generation:
ConfigEOS.settings_generation() counts every _setup() (merge, reset,
revert, update) and every set_nested_value().
cache_in_file also takes key_context_hold: after a change of the key
context, a further change within the hold keeps using the valid entry
of the context in use. The first change, a change after the hold and a
forced update apply at once. A result is only stored under the context
it was computed for. cache_request passes its keyword arguments on to
cache_in_file; with_ttl defaults to REQUEST_CACHE_TTL (1 hour) and also
sets key_context_hold, so settings changes cause at most one extra
request per provider and TTL.
In a simulation of 6 hours of 5-minute runs with an import value pushed
on every run and four location and plane edits, the weather and PV
requests run 6 times (as on main), and every edit reaches the provider
within the hour.
Additional changes
Test that every cached request declares the settings it reads, including
those read by helper methods of its module
Test the settings generation counter, the reuse of the digest, the hold
and the cache_request defaults and pass-through
Add general/timezone to BrightSky (in the URL) and Forecast.Solar
(fallback zone of the response)
Clear the hold state with the whole file cache
Add a CHANGELOG entry
Refs: #1559
Signed-off-by: SchaafAlexander <86607129+SchaafAlexander@users.noreply.github.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Assisted-by: Claude Code (claude-opus-5-5)
1205 lines
48 KiB
Python
1205 lines
48 KiB
Python
"""Tests for the native (pvlib) PV forecast provider."""
|
|
|
|
from typing import Any, Optional
|
|
from unittest.mock import AsyncMock, Mock, patch
|
|
|
|
import numpy as np
|
|
import pandas as pd
|
|
import pendulum
|
|
import pvlib
|
|
import pytest
|
|
import pytest_asyncio
|
|
import requests
|
|
|
|
from akkudoktoreos.core.coreabc import get_ems, get_measurement, get_prediction
|
|
from akkudoktoreos.measurement.quality import MeasurementSample, SampleQuality
|
|
from akkudoktoreos.prediction.pvforecastakkudoktor import PVForecastAkkudoktor
|
|
from akkudoktoreos.prediction.pvforecastakkudoktorlocal import (
|
|
PVForecastAkkudoktorLocal,
|
|
PVForecastAkkudoktorLocalCommonSettings,
|
|
SlotWindow,
|
|
_slot_window,
|
|
_utc_timestamp,
|
|
)
|
|
from akkudoktoreos.utils.datetimeutil import DateTime, compare_datetimes, to_datetime
|
|
|
|
LATITUDE = 52.52
|
|
LONGITUDE = 13.405
|
|
|
|
# A window that starts well before `START` so the calibration fit has past data.
|
|
WINDOW_START = pendulum.datetime(2025, 6, 1, 0, 0, tz="UTC")
|
|
WINDOW_END = pendulum.datetime(2025, 6, 20, 0, 0, tz="UTC")
|
|
START = pendulum.datetime(2025, 6, 15, 0, 0, tz="UTC")
|
|
|
|
|
|
def synthetic_openmeteo(resolution_minutes: int = 15, models: list[str] | None = None) -> dict:
|
|
"""Build an Open-Meteo-shaped response from a pvlib clear-sky series.
|
|
|
|
Open-Meteo stamps an interval mean with the interval END, and that is what the
|
|
provider expects, so the values are generated at those stamps directly.
|
|
"""
|
|
freq = f"{resolution_minutes}min"
|
|
index = pd.date_range(
|
|
start=WINDOW_START.format("YYYY-MM-DD HH:mm"),
|
|
end=WINDOW_END.format("YYYY-MM-DD HH:mm"),
|
|
freq=freq,
|
|
tz="UTC",
|
|
)
|
|
location = pvlib.location.Location(LATITUDE, LONGITUDE, tz="UTC", altitude=37.0)
|
|
clearsky = location.get_clearsky(index, model="ineichen")
|
|
|
|
block = "minutely_15" if resolution_minutes == 15 else "hourly"
|
|
values = {
|
|
"shortwave_radiation": clearsky["ghi"].round(1).tolist(),
|
|
"diffuse_radiation": clearsky["dhi"].round(1).tolist(),
|
|
"direct_normal_irradiance": clearsky["dni"].round(1).tolist(),
|
|
"temperature_2m": [20.0] * len(index),
|
|
"relative_humidity_2m": [50.0] * len(index),
|
|
"wind_speed_10m": [2.0] * len(index),
|
|
}
|
|
|
|
data: dict = {"elevation": 37.0}
|
|
payload = {"time": [t.strftime("%Y-%m-%dT%H:%M") for t in index]}
|
|
if models:
|
|
# Multi-model requests come back with one suffixed series per member.
|
|
for name in models:
|
|
for key, series in values.items():
|
|
payload[f"{key}_{name}"] = series
|
|
else:
|
|
payload.update(values)
|
|
data[block] = payload
|
|
return data
|
|
|
|
|
|
|
|
async def _fit(
|
|
instance: PVForecastAkkudoktorLocal, frame: pd.DataFrame
|
|
) -> Optional[tuple[float, np.ndarray]]:
|
|
"""Fit the calibration as a forecast run does: read the PV meter window, then fit."""
|
|
return await instance._fit_calibration(frame, await instance._pv_measurement_window())
|
|
|
|
|
|
@pytest_asyncio.fixture
|
|
async def pvforecast_instance(config_eos):
|
|
config_eos.merge_settings_from_dict(
|
|
{
|
|
"general": {"latitude": LATITUDE, "longitude": LONGITUDE, "timezone": "UTC"},
|
|
"prediction": {"hours": 96, "historic_hours": 48},
|
|
"pvforecast": {
|
|
"provider": "PVForecastAkkudoktor",
|
|
"planes": [
|
|
{
|
|
"surface_tilt": 30.0,
|
|
"surface_azimuth": 180.0,
|
|
"peakpower": 10.0,
|
|
"inverter_paco": 10000,
|
|
"loss": 14.0,
|
|
}
|
|
],
|
|
"akkudoktor": {"backend": "local", "resolution_minutes": 15},
|
|
},
|
|
}
|
|
)
|
|
provider = PVForecastAkkudoktor()
|
|
get_ems().set_start_datetime(START)
|
|
await provider.delete_by_datetime()
|
|
await get_measurement().delete_by_datetime()
|
|
# Warn-once state lives on the shared singleton; start each test fresh.
|
|
get_measurement()._reported_warnings.clear()
|
|
yield provider
|
|
await provider.delete_by_datetime()
|
|
await get_measurement().delete_by_datetime()
|
|
|
|
|
|
def test_provider_id(pvforecast_instance):
|
|
assert PVForecastAkkudoktorLocal.provider_id() == "PVForecastAkkudoktor"
|
|
assert pvforecast_instance.enabled() is True
|
|
|
|
|
|
@pytest.mark.parametrize("value", [0, 5, 30, 61])
|
|
def test_resolution_must_be_15_or_60(value):
|
|
with pytest.raises(ValueError, match="resolution_minutes must be 15 or 60"):
|
|
PVForecastAkkudoktorLocalCommonSettings(resolution_minutes=value)
|
|
|
|
|
|
def test_invalid_transposition_model():
|
|
with pytest.raises(ValueError, match="Invalid transposition_model"):
|
|
PVForecastAkkudoktorLocalCommonSettings(transposition_model="nonsense")
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_forecast_frame_is_quarter_hourly_and_plausible(pvforecast_instance):
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
|
|
assert not frame.empty
|
|
deltas = frame.index.to_series().diff().dropna().unique()
|
|
assert list(deltas) == [pd.Timedelta(minutes=15)]
|
|
|
|
# A 10 kWp south-facing roof under clear June skies: below the inverter cap,
|
|
# but a substantial fraction of it.
|
|
peak = frame["ac_power"].max()
|
|
assert 5000.0 < peak <= 10000.0
|
|
assert (frame["ac_power"] >= 0.0).all()
|
|
assert (frame["ac_power"] <= frame["dc_power"] + 1e-6).all()
|
|
|
|
# Nights are dark.
|
|
midnight = frame.between_time("00:00", "01:00")["ac_power"]
|
|
assert midnight.max() == pytest.approx(0.0)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_records_are_shifted_to_interval_start(pvforecast_instance):
|
|
"""Open-Meteo labels an interval by its end; EOS labels it by its start."""
|
|
shifted = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
resolution_minutes=15, shift_to_interval_start=False
|
|
)
|
|
raw = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
|
|
assert raw.index[0] - shifted.index[0] == pd.Timedelta(minutes=15)
|
|
assert raw["ac_power"].to_numpy() == pytest.approx(shifted["ac_power"].to_numpy())
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_ensemble_members_are_averaged(pvforecast_instance):
|
|
"""Several models in one request must be averaged, not dropped or duplicated."""
|
|
single = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
ensemble = await pvforecast_instance._forecast_frame(
|
|
synthetic_openmeteo(models=["icon_seamless", "gfs_seamless", "ecmwf_ifs025"])
|
|
)
|
|
|
|
# The synthetic members are identical, so the mean must reproduce the single run.
|
|
assert ensemble["ac_power"].to_numpy() == pytest.approx(single["ac_power"].to_numpy())
|
|
|
|
|
|
def test_horizon_elevation_wraps_around_north():
|
|
horizon = PVForecastAkkudoktorLocal._horizon_elevation(
|
|
[0.0, 10.0, 20.0, 30.0], np.array([0.0, 90.0, 180.0, 270.0, 359.999])
|
|
)
|
|
assert horizon[:4] == pytest.approx([0.0, 10.0, 20.0, 30.0])
|
|
# Wrapping back to due north interpolates from 30 deg towards 0 deg.
|
|
assert horizon[4] == pytest.approx(0.0, abs=0.01)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_horizon_shading_reduces_yield(pvforecast_instance):
|
|
baseline = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
|
|
# A 40 deg wall all around blocks the beam for most of the day.
|
|
pvforecast_instance.config.pvforecast.planes[0].userhorizon = [40.0] * 12
|
|
shaded = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
|
|
assert shaded["ac_power"].sum() < baseline["ac_power"].sum() * 0.9
|
|
assert shaded["ac_power"].min() >= 0.0
|
|
|
|
# The low morning sun (below 40 deg elevation until ~07:00 UTC in June) is behind
|
|
# the wall, so its beam is gone entirely and only diffuse is left.
|
|
assert (
|
|
shaded["ac_power"].between_time("05:00", "07:00").sum()
|
|
< baseline["ac_power"].between_time("05:00", "07:00").sum() * 0.5
|
|
)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_update_data_writes_records(pvforecast_instance):
|
|
with patch.object(
|
|
PVForecastAkkudoktorLocal, "_request_local_forecast", return_value=synthetic_openmeteo()
|
|
):
|
|
await pvforecast_instance._update_data(force_update=True)
|
|
|
|
dates, values = await pvforecast_instance.key_to_lists("pvforecast_ac_power")
|
|
assert len(dates) > 0
|
|
assert all(value is not None for value in values)
|
|
_, dc_values = await pvforecast_instance.key_to_lists("pvforecast_dc_power")
|
|
assert all(value is not None for value in dc_values)
|
|
|
|
|
|
async def _feed_measurements(
|
|
instance: PVForecastAkkudoktorLocal, frame: pd.DataFrame, bias: float, key: str
|
|
) -> None:
|
|
"""Write cumulative PV meter readings that are `bias` times the modelled power.
|
|
|
|
Each test passes its own `key`. `Measurement` is database-backed, so clearing the
|
|
in-memory record list would not remove readings another test already stored.
|
|
"""
|
|
instance.config.measurement.pv_production_emr_keys = [key]
|
|
measurement = get_measurement()
|
|
|
|
hourly = frame["ac_power"].resample("1h").mean()
|
|
hourly = hourly.loc[hourly.index < START]
|
|
|
|
cumulative = 0.0
|
|
for timestamp, power_w in hourly.items():
|
|
timestamp = pd.Timestamp(str(timestamp))
|
|
await measurement.update_value(
|
|
pendulum.instance(timestamp.to_pydatetime()), key, round(cumulative, 6)
|
|
)
|
|
cumulative += float(power_w) * bias / 1000.0
|
|
# Closing reading so the last interval has a difference to work with.
|
|
await measurement.update_value(
|
|
pendulum.instance(hourly.index[-1].to_pydatetime()).add(hours=1),
|
|
key,
|
|
round(cumulative, 6),
|
|
)
|
|
|
|
|
|
async def _feed_measurements_with_recent_outage(
|
|
instance: PVForecastAkkudoktorLocal,
|
|
frame: pd.DataFrame,
|
|
healthy_bias: float,
|
|
outage_bias: float,
|
|
outage_days: int,
|
|
key: str,
|
|
) -> None:
|
|
"""Write a healthy meter history followed by demand-limited PV production."""
|
|
instance.config.measurement.pv_production_emr_keys = [key]
|
|
measurement = get_measurement()
|
|
|
|
hourly = frame["ac_power"].resample("1h").mean()
|
|
hourly = hourly.loc[hourly.index < START]
|
|
outage_start = START.subtract(days=outage_days)
|
|
healthy_looking_gap = outage_start.add(days=2).date()
|
|
|
|
cumulative = 0.0
|
|
for timestamp, power_w in hourly.items():
|
|
timestamp = pd.Timestamp(str(timestamp))
|
|
await measurement.update_value(
|
|
pendulum.instance(timestamp.to_pydatetime()), key, round(cumulative, 6)
|
|
)
|
|
in_outage = timestamp >= outage_start and timestamp.date() != healthy_looking_gap
|
|
bias = outage_bias if in_outage else healthy_bias
|
|
cumulative += float(power_w) * bias / 1000.0
|
|
await measurement.update_value(
|
|
pendulum.instance(hourly.index[-1].to_pydatetime()).add(hours=1),
|
|
key,
|
|
round(cumulative, 6),
|
|
)
|
|
|
|
|
|
async def _feed_native_quarter_hour_measurements(
|
|
instance: PVForecastAkkudoktorLocal, frame: pd.DataFrame, bias: float, key: str
|
|
) -> None:
|
|
"""Write cumulative PV readings at the provider's native 15-minute cadence."""
|
|
instance.config.measurement.pv_production_emr_keys = [key]
|
|
measurement = get_measurement()
|
|
slots = frame.loc[frame.index < START, "ac_power"]
|
|
|
|
cumulative = 0.0
|
|
for timestamp, power_w in slots.items():
|
|
timestamp = pd.Timestamp(str(timestamp))
|
|
await measurement.update_value(
|
|
pendulum.instance(timestamp.to_pydatetime()), key, round(cumulative, 6)
|
|
)
|
|
cumulative += float(power_w) * 0.25 * bias / 1000.0
|
|
await measurement.update_value(
|
|
pendulum.instance(slots.index[-1].to_pydatetime()).add(minutes=15),
|
|
key,
|
|
round(cumulative, 6),
|
|
)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_is_off_by_default(pvforecast_instance):
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
assert await _fit(pvforecast_instance, frame) is None
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_skips_without_measurement_keys(pvforecast_instance):
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_enabled=True
|
|
)
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
assert await _fit(pvforecast_instance, frame) is None
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_recovers_a_systematic_bias(pvforecast_instance):
|
|
"""A plant that consistently delivers 80% of the model must be corrected to 0.8."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_enabled=True,
|
|
calibration_days=14,
|
|
calibration_azimuth_bin_degrees=0,
|
|
)
|
|
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
await _feed_measurements(pvforecast_instance, frame, bias=0.8, key="pv_bias_emr")
|
|
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
assert calibration is not None
|
|
global_factor, factors = calibration
|
|
assert global_factor == pytest.approx(0.8, abs=0.03)
|
|
assert factors == pytest.approx([global_factor])
|
|
|
|
corrected = pvforecast_instance._apply_calibration(frame, factors, 10000.0)
|
|
assert corrected["ac_power"].sum() == pytest.approx(frame["ac_power"].sum() * global_factor)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_excludes_recent_demand_limited_outage(pvforecast_instance, caplog):
|
|
"""A battery outage must not teach demand-limited PV as available generation."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_enabled=True,
|
|
calibration_days=5,
|
|
calibration_reference_days=14,
|
|
calibration_azimuth_bin_degrees=0,
|
|
calibration_min_factor=0.2,
|
|
)
|
|
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
await _feed_measurements_with_recent_outage(
|
|
pvforecast_instance,
|
|
frame,
|
|
healthy_bias=0.8,
|
|
outage_bias=0.2,
|
|
outage_days=5,
|
|
key="pv_demand_limited_emr",
|
|
)
|
|
|
|
with caplog.at_level("INFO"):
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
|
|
assert calibration is not None
|
|
global_factor, factors = calibration
|
|
assert global_factor == pytest.approx(0.8, abs=0.03)
|
|
assert factors == pytest.approx([global_factor])
|
|
assert "excluded probable outage/curtailment days" in caplog.text
|
|
# A single statistically healthy-looking day inside the outage is bridged.
|
|
assert "2025-06-12" in caplog.text
|
|
|
|
# Filtering only selects training data. Applying a global factor preserves the
|
|
# native quarter-hour shape instead of replacing it with hourly bucket values.
|
|
corrected = pvforecast_instance._apply_calibration(frame, factors, 10000.0)
|
|
producing = frame["ac_power"] > 0.0
|
|
assert corrected.index.to_series().diff().dropna().unique().tolist() == [
|
|
pd.Timedelta(minutes=15)
|
|
]
|
|
assert (
|
|
corrected.loc[producing, "ac_power"] / frame.loc[producing, "ac_power"]
|
|
).to_numpy() == pytest.approx(np.full(producing.sum(), global_factor))
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_uses_real_quarter_hour_measurements(pvforecast_instance, caplog):
|
|
"""Native meter slots permit shape calibration without inventing intrahour data."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_enabled=True,
|
|
calibration_days=14,
|
|
calibration_reference_days=14,
|
|
calibration_azimuth_bin_degrees=0,
|
|
)
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
await _feed_native_quarter_hour_measurements(
|
|
pvforecast_instance, frame, bias=0.8, key="pv_quarter_hour_emr"
|
|
)
|
|
|
|
assert (
|
|
await pvforecast_instance._calibration_interval_minutes(START.subtract(days=14), START)
|
|
== 15
|
|
)
|
|
with caplog.at_level("INFO"):
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
|
|
assert calibration is not None
|
|
global_factor, _ = calibration
|
|
assert global_factor == pytest.approx(0.8, abs=0.03)
|
|
assert "15-minute measurement resolution" in caplog.text or "15-minute intervals" in caplog.text
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_meter_resolution_counts_valid_readings_only(pvforecast_instance):
|
|
"""Invalid intrahour readings must not make an hourly meter look quarter-hourly.
|
|
|
|
Fitting native slots on such a meter would interpolate within each hour and
|
|
invent a flat intrahour profile.
|
|
"""
|
|
key = "pv_hourly_valid_emr"
|
|
pvforecast_instance.config.measurement.pv_production_emr_keys = [key]
|
|
start = START.subtract(days=3)
|
|
samples = []
|
|
for slot in range(3 * 24 * 4):
|
|
stamp = start.add(minutes=15 * slot)
|
|
quality = (
|
|
SampleQuality(status="measured") if slot % 4 == 0 else SampleQuality(status="invalid")
|
|
)
|
|
samples.append(
|
|
MeasurementSample(date_time=stamp, key=key, value=float(slot), quality=quality)
|
|
)
|
|
await get_measurement().import_samples(samples)
|
|
|
|
assert await pvforecast_instance._calibration_interval_minutes(start, START) == 60
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_factor_is_clamped(pvforecast_instance):
|
|
"""A wildly wrong meter must not be allowed to swing the forecast."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_enabled=True,
|
|
calibration_days=14,
|
|
calibration_azimuth_bin_degrees=0,
|
|
calibration_min_factor=0.9,
|
|
calibration_max_factor=1.1,
|
|
)
|
|
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
await _feed_measurements(pvforecast_instance, frame, bias=0.2, key="pv_clamp_emr")
|
|
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
assert calibration is not None
|
|
global_factor, _ = calibration
|
|
assert global_factor == pytest.approx(0.9)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_respects_the_inverter_cap(pvforecast_instance):
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
corrected = PVForecastAkkudoktorLocal._apply_calibration(frame, np.array([1.5]), 10000.0)
|
|
assert corrected["ac_power"].max() <= 10000.0 + 1e-6
|
|
|
|
|
|
def test_azimuth_calibration_is_interpolated_smoothly():
|
|
"""Azimuth correction must not introduce steps into the quarter-hour plan."""
|
|
frame = pd.DataFrame(
|
|
{
|
|
"solar_azimuth": [44.9, 45.0, 45.1, 134.9, 135.0, 135.1],
|
|
"dc_power": [1000.0] * 6,
|
|
"ac_power": [1000.0] * 6,
|
|
}
|
|
)
|
|
corrected = PVForecastAkkudoktorLocal._apply_calibration(
|
|
frame, np.array([0.5, 1.0, 1.5, 1.0]), ac_cap_w=2000.0
|
|
)
|
|
|
|
assert corrected.loc[1, "ac_power"] == pytest.approx(500.0)
|
|
assert corrected.loc[4, "ac_power"] == pytest.approx(1000.0)
|
|
values = corrected["ac_power"].to_numpy(dtype=float)
|
|
assert abs(values[2] - values[0]) < 2.0
|
|
assert abs(values[5] - values[3]) < 2.0
|
|
|
|
|
|
def test_azimuth_shape_preserves_each_days_global_energy():
|
|
"""The EMS gets a changed shape without a changed daily energy budget."""
|
|
index = pd.date_range("2025-06-01", periods=8, freq="12h", tz="UTC")
|
|
frame = pd.DataFrame(
|
|
{
|
|
"solar_azimuth": [45.0, 225.0, 45.0, 225.0, 45.0, 225.0, 45.0, 225.0],
|
|
"dc_power": [100.0, 300.0, 200.0, 200.0, 300.0, 100.0, 150.0, 250.0],
|
|
"ac_power": [100.0, 300.0, 200.0, 200.0, 300.0, 100.0, 150.0, 250.0],
|
|
},
|
|
index=index,
|
|
)
|
|
global_factor = 0.8
|
|
corrected = PVForecastAkkudoktorLocal._apply_calibration(
|
|
frame,
|
|
np.array([0.5, 1.0, 1.5, 1.0]),
|
|
ac_cap_w=10_000.0,
|
|
global_factor=global_factor,
|
|
timezone="UTC",
|
|
)
|
|
|
|
raw_daily = frame["ac_power"].resample("1D").sum()
|
|
corrected_daily = corrected["ac_power"].resample("1D").sum()
|
|
assert corrected_daily.to_numpy() == pytest.approx(raw_daily.to_numpy() * global_factor)
|
|
assert np.std(corrected["ac_power"] / frame["ac_power"]) > 0.01
|
|
|
|
|
|
def test_azimuth_shape_fit_preserves_global_energy(pvforecast_instance):
|
|
"""Intraday correction must not undo the independently fitted daily kWh."""
|
|
centers = np.arange(22.5, 360.0, 45.0)
|
|
azimuth = np.repeat(centers, 20)
|
|
modelled_kwh = np.ones(len(azimuth))
|
|
expected_shape = np.repeat([0.8, 0.9, 1.0, 1.1, 1.2, 1.1, 1.0, 0.9], 20)
|
|
global_factor = 0.8
|
|
measured_kwh = modelled_kwh * global_factor * expected_shape
|
|
|
|
factors = pvforecast_instance._fit_azimuth_factors(
|
|
modelled_kwh, measured_kwh, azimuth, global_factor
|
|
)
|
|
fitted_scale = pvforecast_instance._interpolate_azimuth_factors(azimuth, factors)
|
|
|
|
assert np.std(factors) > 0.01
|
|
assert np.dot(modelled_kwh, fitted_scale) == pytest.approx(
|
|
global_factor * modelled_kwh.sum(), rel=1e-6
|
|
)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_forecast_frame_applies_the_calibration(pvforecast_instance):
|
|
"""The correction must reach every caller of the chain, not just `_update_data`."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_enabled=True,
|
|
calibration_days=14,
|
|
calibration_azimuth_bin_degrees=0,
|
|
)
|
|
|
|
raw = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
await _feed_measurements(pvforecast_instance, raw, bias=0.8, key="pv_chain_emr")
|
|
|
|
calibrated = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
ratio = calibrated["ac_power"].sum() / raw["ac_power"].sum()
|
|
assert ratio == pytest.approx(0.8, abs=0.03)
|
|
|
|
|
|
def test_transient_weather_outage_is_retried(pvforecast_instance):
|
|
"""Open-Meteo answers 503 while rotating model runs; that clears in seconds."""
|
|
error = requests.exceptions.HTTPError("503 Server Error")
|
|
error.response = Mock(status_code=503)
|
|
good = Mock()
|
|
good.url = "https://api.open-meteo.com/v1/forecast"
|
|
good.raise_for_status.return_value = None
|
|
good.json.return_value = synthetic_openmeteo()
|
|
|
|
failing = Mock()
|
|
failing.url = good.url
|
|
failing.raise_for_status.side_effect = error
|
|
|
|
with (
|
|
patch(
|
|
"akkudoktoreos.prediction.pvforecastakkudoktorlocal.requests.get",
|
|
side_effect=[failing, good],
|
|
) as request,
|
|
patch("akkudoktoreos.prediction.pvforecastakkudoktorlocal.time.sleep"),
|
|
):
|
|
data = pvforecast_instance._request_local_forecast(force_update=True)
|
|
|
|
assert request.call_count == 2
|
|
assert "minutely_15" in data
|
|
|
|
|
|
def test_weather_request_cache_follows_the_configuration(pvforecast_instance, monkeypatch):
|
|
"""A configuration change must not get the cached response of the old one (#1559).
|
|
|
|
Only the settings the request reads count, and settings changes cause at most one
|
|
extra request per hour.
|
|
"""
|
|
sent: list[tuple[int, float]] = []
|
|
now = [to_datetime("2026-11-15T12:00:00+00:00")]
|
|
monkeypatch.setattr("akkudoktoreos.core.cache._hold_now", lambda: now[0])
|
|
monkeypatch.setattr("akkudoktoreos.core.cache._key_context_states", {})
|
|
|
|
def respond(url, params, timeout):
|
|
sent.append((params["past_days"], params["latitude"]))
|
|
response = Mock()
|
|
response.url = url
|
|
response.raise_for_status.return_value = None
|
|
response.json.return_value = synthetic_openmeteo()
|
|
return response
|
|
|
|
config = pvforecast_instance.config
|
|
with patch(
|
|
"akkudoktoreos.prediction.pvforecastakkudoktorlocal.requests.get", side_effect=respond
|
|
):
|
|
pvforecast_instance._request_local_forecast(force_update=True)
|
|
pvforecast_instance._request_local_forecast() # unchanged: from the cache
|
|
# A setting the request does not read, e.g. pushed by an adapter on every run.
|
|
config.set_nested_value("elecprice/elecpriceimport/import_json", '{"a": [1.0]}')
|
|
pvforecast_instance._request_local_forecast()
|
|
# Calibration needs the weather of its lookback: more past days.
|
|
config.merge_settings_from_dict(
|
|
{"pvforecast": {"akkudoktor": {"calibration_enabled": True}}}
|
|
)
|
|
pvforecast_instance._request_local_forecast()
|
|
# A second change within the hour keeps the response until an hour after the first.
|
|
now[0] = now[0].add(minutes=10)
|
|
config.merge_settings_from_dict({"general": {"latitude": 48.14, "longitude": 11.58}})
|
|
pvforecast_instance._request_local_forecast()
|
|
now[0] = now[0].add(minutes=51)
|
|
pvforecast_instance._request_local_forecast()
|
|
|
|
assert sent == [(2, LATITUDE), (30, LATITUDE), (30, 48.14)]
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_weather_outage_keeps_the_previous_forecast(pvforecast_instance):
|
|
"""One dead weather API must not take the whole prediction update down.
|
|
|
|
`PredictionContainer.update_data` re-raises whatever an enabled provider
|
|
raises, so every provider after this one would be skipped and the endpoint
|
|
would answer 400. This fixture retains future samples from the previous run.
|
|
"""
|
|
# The stored forecast has to reach past the run start for the fallback to be
|
|
# worth anything, so put the run inside the synthetic window.
|
|
get_ems().set_start_datetime(WINDOW_START.add(days=1))
|
|
with patch.object(
|
|
pvforecast_instance,
|
|
"_request_local_forecast",
|
|
return_value=synthetic_openmeteo(),
|
|
):
|
|
await pvforecast_instance._update_data(force_update=True)
|
|
stored = await pvforecast_instance.max_datetime()
|
|
assert stored is not None
|
|
records_before = len(pvforecast_instance)
|
|
|
|
with patch.object(
|
|
pvforecast_instance,
|
|
"_request_local_forecast",
|
|
side_effect=RuntimeError("Failed to fetch weather from Open-Meteo API"),
|
|
):
|
|
await pvforecast_instance._update_data(force_update=True)
|
|
|
|
assert await pvforecast_instance.max_datetime() == stored
|
|
assert len(pvforecast_instance) == records_before
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_weather_outage_without_any_forecast_still_fails(pvforecast_instance):
|
|
"""A cold start has nothing to fall back to, so the caller must hear about it.
|
|
|
|
The stored forecast lives in the backing store, not in `records`, so an empty
|
|
store is what a cold start actually looks like.
|
|
"""
|
|
await pvforecast_instance.delete_by_datetime()
|
|
with patch.object(
|
|
pvforecast_instance,
|
|
"_request_local_forecast",
|
|
side_effect=RuntimeError("Failed to fetch weather from Open-Meteo API"),
|
|
):
|
|
with pytest.raises(RuntimeError, match="Failed to fetch weather"):
|
|
await pvforecast_instance._update_data(force_update=True)
|
|
|
|
|
|
def test_remote_backend_is_the_compatible_default():
|
|
assert PVForecastAkkudoktorLocalCommonSettings().backend == "remote"
|
|
|
|
|
|
def test_calibration_rejects_inverted_bounds():
|
|
with pytest.raises(ValueError, match="must not exceed"):
|
|
PVForecastAkkudoktorLocalCommonSettings(
|
|
calibration_min_factor=1.5, calibration_max_factor=0.5
|
|
)
|
|
|
|
|
|
def test_existing_provider_id_is_registered_once(pvforecast_instance):
|
|
providers = get_prediction().providers
|
|
selected = [p for p in providers if p.provider_id() == "PVForecastAkkudoktor"]
|
|
assert selected == [pvforecast_instance]
|
|
assert all(p.provider_id() != "PVForecastAkkudoktorLocal" for p in providers)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_local_power_contract_for_hourly_and_quarter_hour_consumers(pvforecast_instance):
|
|
"""Both optimizer cadences receive W, ready for their W-to-Wh conversion."""
|
|
start = START.add(hours=12)
|
|
frame = pd.DataFrame(
|
|
{
|
|
"ac_power": [1000.0, 2000.0, 3000.0, 4000.0],
|
|
"dc_power": [1100.0, 2200.0, 3300.0, 4400.0],
|
|
},
|
|
index=pd.date_range(start=start, periods=4, freq="15min"),
|
|
)
|
|
with (
|
|
patch.object(pvforecast_instance, "_request_local_forecast", return_value={}),
|
|
patch.object(pvforecast_instance, "_forecast_frame", new=AsyncMock(return_value=frame)),
|
|
patch.object(pvforecast_instance, "_request_forecast") as remote,
|
|
):
|
|
await pvforecast_instance._update_data(force_update=True)
|
|
remote.assert_not_called()
|
|
quarter_power = await get_prediction().key_to_array(
|
|
"pvforecast_ac_power",
|
|
start_datetime=start,
|
|
end_datetime=start.add(hours=1),
|
|
interval=pendulum.duration(minutes=15),
|
|
)
|
|
hourly_power = await get_prediction().key_to_array(
|
|
"pvforecast_ac_power",
|
|
start_datetime=start,
|
|
end_datetime=start.add(hours=1),
|
|
interval=pendulum.duration(hours=1),
|
|
)
|
|
assert quarter_power == pytest.approx([1000.0, 2000.0, 3000.0, 4000.0])
|
|
assert hourly_power == pytest.approx([2500.0])
|
|
assert float(sum(quarter_power * 0.25)) == pytest.approx(float(sum(hourly_power)))
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
@pytest.mark.parametrize("record", ["expired_power", "future_measurement_only"])
|
|
async def test_outage_does_not_accept_unusable_stored_data(pvforecast_instance, record):
|
|
if record == "expired_power":
|
|
await pvforecast_instance.update_value(
|
|
START.subtract(hours=1), "pvforecast_ac_power", 1000.0
|
|
)
|
|
else:
|
|
await pvforecast_instance.update_value(
|
|
START.add(hours=1), "pvforecastakkudoktor_ac_power_measured", 1000.0
|
|
)
|
|
with patch.object(
|
|
pvforecast_instance, "_request_local_forecast", side_effect=RuntimeError("outage")
|
|
):
|
|
with pytest.raises(RuntimeError, match="outage"):
|
|
await pvforecast_instance._update_data(force_update=True)
|
|
|
|
|
|
@pytest.mark.parametrize("through_file_migration", [False, True])
|
|
def test_feature_settings_migrate_without_loss_or_input_mutation(
|
|
config_eos, through_file_migration
|
|
):
|
|
import copy
|
|
|
|
from akkudoktoreos.config.configmigrate import migrate_config_data
|
|
from akkudoktoreos.prediction.pvforecast import PVForecastCommonSettings
|
|
|
|
source = {
|
|
"provider": "PVForecastAkkudoktorLocal",
|
|
"provider_settings": {
|
|
"PVForecastAkkudoktorLocal": {
|
|
"calibration_enabled": True,
|
|
"calibration_days": 21,
|
|
"calibration_min_factor": 1.7,
|
|
"calibration_max_factor": 2.1,
|
|
}
|
|
},
|
|
}
|
|
before = copy.deepcopy(source)
|
|
if through_file_migration:
|
|
migrated = migrate_config_data({"pvforecast": source}).pvforecast
|
|
else:
|
|
migrated = PVForecastCommonSettings.model_validate(source)
|
|
assert source == before
|
|
assert migrated.provider == "PVForecastAkkudoktor"
|
|
assert migrated.akkudoktor.backend == "local"
|
|
assert migrated.akkudoktor.calibration_enabled
|
|
assert migrated.akkudoktor.calibration_days == 21
|
|
assert migrated.akkudoktor.calibration_min_factor == 1.7
|
|
assert migrated.akkudoktor.calibration_max_factor == 2.1
|
|
|
|
|
|
def test_current_pv_settings_take_precedence_during_migration(config_eos):
|
|
from akkudoktoreos.config.configmigrate import migrate_config_data
|
|
|
|
migrated = migrate_config_data(
|
|
{
|
|
"pvforecast": {
|
|
"provider": "PVForecastAkkudoktorLocal",
|
|
"provider_settings": {
|
|
"PVForecastAkkudoktorLocal": {
|
|
"calibration_enabled": True,
|
|
"calibration_days": 21,
|
|
}
|
|
},
|
|
"akkudoktor": {"backend": "remote", "calibration_days": 7},
|
|
}
|
|
}
|
|
).pvforecast
|
|
assert migrated.provider == "PVForecastAkkudoktor"
|
|
assert migrated.akkudoktor.backend == "remote"
|
|
assert migrated.akkudoktor.calibration_days == 7
|
|
assert migrated.akkudoktor.calibration_enabled
|
|
|
|
|
|
@pytest.mark.parametrize(
|
|
"invalid",
|
|
[
|
|
{"resolution_minutes": 5},
|
|
{"calibration_min_factor": 2.0, "calibration_max_factor": 1.0},
|
|
"invalid",
|
|
],
|
|
)
|
|
def test_file_migration_rejects_invalid_local_settings(config_eos, invalid):
|
|
from akkudoktoreos.config.configmigrate import migrate_config_data
|
|
|
|
with pytest.raises(ValueError):
|
|
migrate_config_data(
|
|
{
|
|
"pvforecast": {
|
|
"provider": "PVForecastAkkudoktorLocal",
|
|
"provider_settings": {"PVForecastAkkudoktorLocal": invalid},
|
|
}
|
|
}
|
|
)
|
|
|
|
|
|
@pytest.mark.parametrize(
|
|
("interval_minutes", "lookback_start", "last", "earliest", "expected"),
|
|
[
|
|
pytest.param(
|
|
15,
|
|
"2025-06-01T00:00:00Z",
|
|
"2025-06-02T00:07:00Z",
|
|
["2025-06-01T00:04:50Z"],
|
|
("2025-06-01T00:15:00Z", "2025-06-02T00:00:00Z"),
|
|
id="unaligned-earliest-rounds-up-to-first-covered-slot",
|
|
),
|
|
pytest.param(
|
|
15,
|
|
"2025-06-01T00:00:00Z",
|
|
"2025-06-02T00:00:00Z",
|
|
["2025-06-01T00:15:00Z"],
|
|
("2025-06-01T00:15:00Z", "2025-06-02T00:00:00Z"),
|
|
id="on-grid-earliest-is-kept",
|
|
),
|
|
pytest.param(
|
|
15,
|
|
"2025-06-01T00:07:00Z",
|
|
"2025-06-02T00:00:00Z",
|
|
["2025-05-01T00:04:50Z", pd.Timestamp("2025-05-31T23:45:00Z")],
|
|
("2025-06-01T00:15:00Z", "2025-06-02T00:00:00Z"),
|
|
id="lookback-limited-rounds-up-into-the-lookback",
|
|
),
|
|
pytest.param(
|
|
60,
|
|
"2025-06-01T06:00:00+05:45",
|
|
"2025-06-02T06:00:00+05:45",
|
|
[pd.Timestamp("2025-05-31T23:45:00")],
|
|
("2025-06-01T01:00:00Z", "2025-06-02T00:00:00Z"),
|
|
id="quarter-hour-offset-zone-on-utc-grid-naive-model-stamp-is-utc",
|
|
),
|
|
],
|
|
)
|
|
def test_slot_window_bounds_share_the_utc_slot_grid(
|
|
interval_minutes: int,
|
|
lookback_start: str,
|
|
last: str,
|
|
earliest: list[str | pd.Timestamp],
|
|
expected: tuple[str, str],
|
|
) -> None:
|
|
window = _slot_window(
|
|
interval_minutes,
|
|
to_datetime(lookback_start),
|
|
to_datetime(last),
|
|
[value if isinstance(value, pd.Timestamp) else to_datetime(value) for value in earliest],
|
|
)
|
|
|
|
assert window == SlotWindow(start=pd.Timestamp(expected[0]), end=pd.Timestamp(expected[1]))
|
|
assert window.start_datetime.timezone_name == "UTC"
|
|
assert compare_datetimes(window.start_datetime, to_datetime(expected[0])).equal
|
|
|
|
|
|
def test_slot_window_without_a_whole_slot_is_none() -> None:
|
|
window = _slot_window(
|
|
60,
|
|
to_datetime("2025-06-01T00:00:00Z"),
|
|
to_datetime("2025-06-01T01:30:00Z"),
|
|
[to_datetime("2025-06-01T00:10:00Z")],
|
|
)
|
|
|
|
assert window is None
|
|
|
|
|
|
def _unaligned_meter_series(
|
|
frame: pd.DataFrame,
|
|
bias: float,
|
|
first: DateTime,
|
|
until: DateTime,
|
|
cadence_minutes: int,
|
|
timezone: str = "UTC",
|
|
interval_start_labels: bool = True,
|
|
) -> pd.Series:
|
|
"""Cumulative readings of a real-world-like meter: jittered cadence, unaligned stamps.
|
|
|
|
Home Assistant style meters report whenever they change, so neither the first
|
|
reading nor any later reading falls on a slot boundary. The meter measures
|
|
``bias`` times the modelled power; the stamps carry ``timezone``.
|
|
"""
|
|
row_start = pd.DatetimeIndex(frame.index)
|
|
row_length = row_start[1] - row_start[0]
|
|
if not interval_start_labels:
|
|
row_start = row_start - row_length
|
|
epoch = pd.Timestamp(0, tz="UTC")
|
|
energy_kwh = frame["ac_power"].to_numpy(dtype=float) * row_length.total_seconds() / 3600.0
|
|
# Cumulative energy at every row boundary, interpolated to the meter stamps.
|
|
boundaries = pd.DatetimeIndex([*row_start, row_start[-1] + row_length]) - epoch
|
|
cumulative = np.concatenate([[0.0], np.cumsum(energy_kwh * bias / 1000.0)])
|
|
jitter = [0, 21, 47, 13, 34]
|
|
stamps = []
|
|
stamp = _utc_timestamp(first)
|
|
end = _utc_timestamp(until)
|
|
while stamp < end:
|
|
stamps.append(stamp)
|
|
stamp += pd.Timedelta(minutes=cadence_minutes, seconds=jitter[len(stamps) % len(jitter)])
|
|
index = pd.DatetimeIndex(stamps)
|
|
values = np.interp(
|
|
(index - epoch).total_seconds(), boundaries.total_seconds(), cumulative
|
|
).round(3)
|
|
return pd.Series(values, index=index.tz_convert(timezone))
|
|
|
|
|
|
async def _feed_meters(instance: PVForecastAkkudoktorLocal, meters: dict[str, pd.Series]) -> None:
|
|
"""Configure ``meters`` as the PV production meters and store their readings."""
|
|
instance.config.measurement.pv_production_emr_keys = list(meters)
|
|
measurement = get_measurement()
|
|
for key, series in meters.items():
|
|
await measurement.key_from_series(key, series)
|
|
|
|
|
|
@pytest.fixture
|
|
def recorded_windows(monkeypatch) -> list[tuple[DateTime, DateTime]]:
|
|
"""Record the (start, end) of every PV production energy query."""
|
|
windows: list[tuple[DateTime, DateTime]] = []
|
|
production_total_kwh = PVForecastAkkudoktorLocal._pv_production_total_kwh
|
|
|
|
async def recording_production_total_kwh(self, start_datetime, end_datetime, interval):
|
|
windows.append((start_datetime, end_datetime))
|
|
return await production_total_kwh(self, start_datetime, end_datetime, interval)
|
|
|
|
monkeypatch.setattr(
|
|
PVForecastAkkudoktorLocal, "_pv_production_total_kwh", recording_production_total_kwh
|
|
)
|
|
return windows
|
|
|
|
|
|
def _calibration_settings(**overrides: Any) -> PVForecastAkkudoktorLocalCommonSettings:
|
|
"""Calibration over 30 days with 45-degree azimuth bins.
|
|
|
|
The bins expose a slot shift between measured and modelled energy: on a clear-sky
|
|
day a shift lowers the morning bins and raises the evening ones (or the reverse),
|
|
while the global factor barely moves.
|
|
"""
|
|
settings: dict[str, Any] = {
|
|
"calibration_enabled": True,
|
|
"calibration_days": 30,
|
|
"calibration_reference_days": 30,
|
|
"calibration_azimuth_bin_degrees": 45,
|
|
**overrides,
|
|
}
|
|
return PVForecastAkkudoktorLocalCommonSettings(**settings)
|
|
|
|
|
|
def _assert_fitted_bias(
|
|
calibration: Optional[tuple[float, np.ndarray]], bias: float, cadence_minutes: int = 5
|
|
) -> None:
|
|
"""The global factor and every azimuth-bin factor recover the meter bias.
|
|
|
|
An hourly meter is interpolated linearly across the curved dawn and dusk
|
|
production, which moves those bins by a few percent in the same direction;
|
|
a slot shift would move east and west bins in opposite directions.
|
|
"""
|
|
assert calibration is not None
|
|
global_factor, factors = calibration
|
|
assert global_factor == pytest.approx(bias, abs=0.01)
|
|
np.testing.assert_allclose(factors, bias, atol=0.02 if cadence_minutes <= 15 else 0.05)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
@pytest.mark.parametrize(
|
|
("timezone", "first", "cadence_minutes", "interval_minutes", "expected_start"),
|
|
[
|
|
pytest.param(
|
|
"UTC", "2025-06-09T00:04:50Z", 5, 15, "2025-06-09T00:15:00Z", id="meter-start-15min"
|
|
),
|
|
pytest.param(
|
|
"Asia/Kathmandu",
|
|
"2025-06-09T00:04:50Z",
|
|
5,
|
|
15,
|
|
"2025-06-09T00:15:00Z",
|
|
id="meter-start-15min-offset-zone",
|
|
),
|
|
pytest.param(
|
|
"Asia/Kathmandu",
|
|
"2025-06-09T00:04:50Z",
|
|
60,
|
|
60,
|
|
"2025-06-09T01:00:00Z",
|
|
id="meter-start-hourly-offset-zone",
|
|
),
|
|
pytest.param(
|
|
"UTC", "2025-05-31T20:04:50Z", 5, 15, "2025-05-31T23:45:00Z", id="model-start-15min"
|
|
),
|
|
],
|
|
)
|
|
async def test_calibration_with_short_unaligned_meter_history(
|
|
pvforecast_instance,
|
|
recorded_windows,
|
|
timezone: str,
|
|
first: str,
|
|
cadence_minutes: int,
|
|
interval_minutes: int,
|
|
expected_start: str,
|
|
):
|
|
"""A PV meter younger than the lookback window must still be fitted.
|
|
|
|
Regression: the window start was taken from the first PV reading (e.g. 00:04:50)
|
|
without snapping it to the slot grid, so the model grid (00:19:50, 00:34:50, ...)
|
|
never hit a resampled model row and every interval was discarded as NaN. The
|
|
window must start at the first slot the readings fully cover and hold whole
|
|
slots on the UTC grid, also in zones with a quarter-hour offset, and measured
|
|
and modelled energy must line up slot by slot.
|
|
"""
|
|
pvforecast_instance.config.merge_settings_from_dict(
|
|
{"general": {"timezone_override": timezone}}
|
|
)
|
|
assert pvforecast_instance.config.general.timezone == timezone
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(
|
|
frame, 0.8, to_datetime(first), START, cadence_minutes, timezone=timezone
|
|
)
|
|
await _feed_meters(pvforecast_instance, {f"pv_unaligned_emr_{cadence_minutes}": meter})
|
|
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
|
|
_assert_fitted_bias(calibration, 0.8, cadence_minutes)
|
|
start, end = recorded_windows[0]
|
|
assert compare_datetimes(start, to_datetime(expected_start)).equal
|
|
slot_seconds = interval_minutes * 60
|
|
assert start.timestamp() % slot_seconds == 0
|
|
assert end.timestamp() % slot_seconds == 0
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_bins_interval_end_labels_by_interval_start(pvforecast_instance):
|
|
"""With ``shift_to_interval_start=False`` the rows keep Open-Meteo's end stamps.
|
|
|
|
Each row still covers the interval before its label, so the fit must bin it into
|
|
the meter slot of that interval, not into the next one.
|
|
"""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(
|
|
shift_to_interval_start=False
|
|
)
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(
|
|
frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5, interval_start_labels=False
|
|
)
|
|
await _feed_meters(pvforecast_instance, {"pv_end_labels_emr": meter})
|
|
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
|
|
_assert_fitted_bias(calibration, 0.8)
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_window_is_common_to_all_pv_meters(
|
|
pvforecast_instance, recorded_windows
|
|
):
|
|
"""Every PV meter must cover the window; one meter alone does not count.
|
|
|
|
Meter A runs the whole period, meter B starts later and stops earlier. The fit
|
|
may only use the period both report, which is also where their sum is the plant.
|
|
"""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter_a = _unaligned_meter_series(frame, 0.4, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
|
meter_b = _unaligned_meter_series(
|
|
frame, 0.4, to_datetime("2025-06-11T03:02:10Z"), to_datetime("2025-06-13T20:00:00Z"), 5
|
|
)
|
|
await _feed_meters(pvforecast_instance, {"pv_common_a_emr": meter_a, "pv_common_b_emr": meter_b})
|
|
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
|
|
_assert_fitted_bias(calibration, 0.8)
|
|
start, end = recorded_windows[0]
|
|
assert compare_datetimes(start, to_datetime("2025-06-11T03:15:00Z")).equal
|
|
assert compare_datetimes(end, to_datetime("2025-06-13T19:45:00Z")).equal
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_forecast_reads_the_pv_meter_window_once(pvforecast_instance, monkeypatch):
|
|
"""Calibration and snow feedback share one scan of the PV meter readings."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(snow_enabled=True)
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
|
await _feed_meters(pvforecast_instance, {"pv_read_once_emr": meter})
|
|
reads = 0
|
|
measurement_window = PVForecastAkkudoktorLocal._pv_measurement_window
|
|
|
|
async def counting_measurement_window(self):
|
|
nonlocal reads
|
|
reads += 1
|
|
return await measurement_window(self)
|
|
|
|
monkeypatch.setattr(
|
|
PVForecastAkkudoktorLocal, "_pv_measurement_window", counting_measurement_window
|
|
)
|
|
|
|
await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
|
|
assert reads == 1
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_snow_feedback_window_is_on_the_slot_grid(pvforecast_instance, recorded_windows):
|
|
"""Snow feedback compares the same whole UTC slots as the calibration fit."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(
|
|
calibration_enabled=False, snow_lookback_days=7
|
|
)
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
|
await _feed_meters(pvforecast_instance, {"pv_snow_window_emr": meter})
|
|
pv_window = await pvforecast_instance._pv_measurement_window()
|
|
assert pv_window is not None
|
|
|
|
observations, interval_hours = await pvforecast_instance._snow_observations(frame, pv_window)
|
|
|
|
assert interval_hours == 0.25
|
|
assert observations
|
|
start, end = recorded_windows[0]
|
|
assert compare_datetimes(start, to_datetime("2025-06-09T00:15:00Z")).equal
|
|
# The end is the last slot boundary before the last reading.
|
|
assert end.timestamp() % 900 == 0
|
|
assert compare_datetimes(end, pv_window.last).le
|
|
assert compare_datetimes(end.add(minutes=15), pv_window.last).gt
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_falls_back_when_the_meter_conversion_fails(
|
|
pvforecast_instance, monkeypatch, caplog
|
|
):
|
|
"""A broken PV meter history disables calibration instead of the forecast."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings(snow_enabled=True)
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
|
await _feed_meters(pvforecast_instance, {"pv_broken_emr": meter})
|
|
|
|
async def failing_production_total_kwh(self, start_datetime, end_datetime, interval):
|
|
raise ValueError("Overlapping source energy intervals.")
|
|
|
|
monkeypatch.setattr(
|
|
PVForecastAkkudoktorLocal, "_pv_production_total_kwh", failing_production_total_kwh
|
|
)
|
|
|
|
with caplog.at_level("ERROR"):
|
|
forecast = await pvforecast_instance._forecast_frame(synthetic_openmeteo())
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
|
|
assert calibration is None
|
|
np.testing.assert_allclose(forecast["ac_power"], frame["ac_power"])
|
|
assert "calibration: PV meter energy conversion failed" in caplog.text
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_calibration_warns_about_a_stale_common_meter_period(pvforecast_instance, caplog):
|
|
"""A PV meter that stopped reporting holds the fit on old data - say so."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
|
await _feed_meters(pvforecast_instance, {"pv_stale_emr": meter})
|
|
|
|
def stale_warnings() -> int:
|
|
return sum(
|
|
record.levelname == "WARNING"
|
|
and "meter 'pv_stale_emr' last reported at" in record.getMessage()
|
|
for record in caplog.records
|
|
)
|
|
|
|
with caplog.at_level("WARNING"):
|
|
get_ems().set_start_datetime(START.add(hours=12))
|
|
await _fit(pvforecast_instance, frame)
|
|
fresh = stale_warnings()
|
|
get_ems().set_start_datetime(START.add(days=3))
|
|
calibration = await _fit(pvforecast_instance, frame)
|
|
first_stale_run = stale_warnings()
|
|
await _fit(pvforecast_instance, frame)
|
|
|
|
_assert_fitted_bias(calibration, 0.8)
|
|
assert fresh == 0
|
|
assert first_stale_run > 0
|
|
# Once per stale period, not on every run.
|
|
assert stale_warnings() == first_stale_run
|
|
|
|
|
|
@pytest.mark.asyncio
|
|
async def test_pv_meter_window_skips_readings_that_vanish_between_scans(
|
|
pvforecast_instance, monkeypatch
|
|
):
|
|
"""Readings removed between the first and last scan give no window, not an error."""
|
|
pvforecast_instance.config.pvforecast.akkudoktor = _calibration_settings()
|
|
frame = await pvforecast_instance._forecast_frame(synthetic_openmeteo(), calibrate=False)
|
|
meter = _unaligned_meter_series(frame, 0.8, to_datetime("2025-06-09T00:04:50Z"), START, 5)
|
|
await _feed_meters(pvforecast_instance, {"pv_vanishing_emr": meter})
|
|
monkeypatch.setattr(
|
|
type(get_measurement()), "keys_last_datetime", AsyncMock(return_value={})
|
|
)
|
|
|
|
assert await pvforecast_instance._pv_measurement_window() is None
|